Atom-Thin SnS2-xSex with Adjustable Compositions by Direct Liquid Exfoliation from Single Crystals.
Yang, Zhanhai; Liang, Hui; Wang, Xusheng; Ma, Xinlei; Zhang, Tao; Yang, Yanlian; Xie, Liming; Chen, Dong; Long, Yujia; Chen, Jitao; Chang, Yunjie; Yan, Chunhua; Zhang, Xinxiang; Zhang, Xueji; Ge, Binghui; Ren, Zhian; Xue, Mianqi; Chen, Genfu
2016-01-26
Two-dimensional (2D) chalcogenide materials are fundamentally and technologically fascinating for their suitable band gap energy and carrier type relevant to their adjustable composition, structure, and dimensionality. Here, we demonstrate the exfoliation of single-crystal SnS2-xSex (SSS) with S/Se vacancies into an atom-thin layer by simple sonication in ethanol without additive. The introduction of vacancies at the S/Se site, the conflicting atomic radius of sulfur in selenium layers, and easy incorporation with an ethanol molecule lead to high ion accessibility; therefore, atom-thin SSS flakes can be effectively prepared by exfoliating the single crystal via sonication. The in situ pyrolysis of such materials can further adjust their compositions, representing tunable activation energy, band gap, and also tunable response to analytes of such materials. As the most basic and crucial step of the 2D material field, the successful synthesis of an uncontaminated and atom-thin sample will further push ahead the large-scale applications of 2D materials, including, but not limited to, electronics, sensing, catalysis, and energy storage fields.
Tunable optical limiting optofluidic device filled with graphene oxide dispersion in ethanol
Fang, Chaolong; Dai, Bo; Hong, Ruijin; Tao, Chunxian; Wang, Qi; Wang, Xu; Zhang, Dawei; Zhuang, Songlin
2015-01-01
An optofluidic device with tunable optical limiting property is proposed and demonstrated. The optofluidic device is designed for adjusting the concentration of graphene oxide (GO) in the ethanol solution and fabricated by photolithography technique. By controlling the flow rate ratio of the injection, the concentration of GO can be precisely adjusted so that the optical nonlinearity can be changed. The nonlinear optical properties and dynamic excitation relaxation of the GO/ethanol solution are investigated by using Z-scan and pump-probe measurements in the femtosecond regime within the 1.5 μm telecom band. The GO/ethanol solution presents ultrafast recovery time. Besides, the optical limiting property is in proportion to the concentration of the solution. Thus, the threshold power and the saturated power of the optical limiting property can be simply and efficiently manipulated by controlling the flow rate ratio of the injection. Furthermore, the amplitude regeneration is demonstrated by employing the proposed optofluidic device. The signal quality of intensity-impaired femtosecond pulse is significantly improved. The optofluidic device is compact and has long interaction length of optical field and nonlinear material. Heat can be dissipated in the solution and nonlinear material is isolated from other optical components, efficiently avoiding thermal damage and mechanical damage. PMID:26477662
Materials Problems in Chemical Liquid-Propellant Rocket Systems
NASA Technical Reports Server (NTRS)
Gilbert, L. L.
1959-01-01
With the advent of the space age, new adjustments in technical thinking and engineering experience are necessary. There is an increasing and extensive interest in the utilization of materials for components to be used at temperatures ranging from -423 to over 3500 deg F. This paper presents a description of the materials problems associated with the various components of chemical liquid rocket systems. These components include cooled and uncooled thrust chambers, injectors, turbine drive systems, propellant tanks, and cryogenic propellant containers. In addition to materials limitations associated with these components, suggested research approaches for improving materials properties are made. Materials such as high-temperature alloys, cermets, carbides, nonferrous alloys, plastics, refractory metals, and porous materials are considered.
10 CFR 440.18 - Allowable expenditures.
Code of Federal Regulations, 2014 CFR
2014-01-01
... part for labor, weatherization materials, and related matters for a renewable energy system, shall not... beginning in calendar year 2010 and the $3,000 average for renewable energy systems will be adjusted... compliance with the per-home expenditure limit in § 440.18. Each dwelling unit must receive a new energy...
10 CFR 440.18 - Allowable expenditures.
Code of Federal Regulations, 2013 CFR
2013-01-01
... part for labor, weatherization materials, and related matters for a renewable energy system, shall not... beginning in calendar year 2010 and the $3,000 average for renewable energy systems will be adjusted... compliance with the per-home expenditure limit in § 440.18. Each dwelling unit must receive a new energy...
10 CFR 440.18 - Allowable expenditures.
Code of Federal Regulations, 2012 CFR
2012-01-01
... part for labor, weatherization materials, and related matters for a renewable energy system, shall not... beginning in calendar year 2010 and the $3,000 average for renewable energy systems will be adjusted... compliance with the per-home expenditure limit in § 440.18. Each dwelling unit must receive a new energy...
NASA Astrophysics Data System (ADS)
Völker, Benjamin; Landis, Chad M.; Kamlah, Marc
2012-03-01
Within a knowledge-based multiscale simulation approach for ferroelectric materials, the atomic level can be linked to the mesoscale by transferring results from first-principles calculations into a phase-field model. A recently presented routine (Völker et al 2011 Contin. Mech. Thermodyn. 23 435-51) for adjusting the Helmholtz free energy coefficients to intrinsic and extrinsic ferroelectric material properties obtained by DFT calculations and atomistic simulations was subject to certain limitations: caused by too small available degrees of freedom, an independent adjustment of the spontaneous strains and piezoelectric coefficients was not possible, and the elastic properties could only be considered in cubic instead of tetragonal symmetry. In this work we overcome such restrictions by expanding the formulation of the free energy function, i.e. by motivating and introducing new higher-order terms that have not appeared in the literature before. Subsequently we present an improved version of the adjustment procedure for the free energy coefficients that is solely based on input parameters from first-principles calculations performed by Marton and Elsässer, as documented in Völker et al (2011 Contin. Mech. Thermodyn. 23 435-51). Full sets of adjusted free energy coefficients for PbTiO3 and tetragonal Pb(Zr,Ti)O3 are presented, and the benefits of the newly introduced higher-order free energy terms are discussed.
Process Development for Spray Drying a Value-Added Extract from Aflatoxin Contaminated Peanut Meal
USDA-ARS?s Scientific Manuscript database
Peanut meal, the primary byproduct of commercial oil crushing operations, is an excellent source of protein though aflatoxin contamination often limits applications for this material. Naturally aflatoxin contaminated (59 ppb) peanut meal dispersions were adjusted to pH 2.1 or pH 9.1, with or without...
Code of Federal Regulations, 2012 CFR
2012-04-01
... natural wine from juice having a fixed acid level exceeding 5.0 grams per liter, the winemaker may adjust... acid level of the juice or wine by 0.1 gram per liter (the fixed acid level of the juice or wine may not be less than 5.0 gram per liter after the addition of ameliorating material). (b) Limitations. (1...
Code of Federal Regulations, 2014 CFR
2014-04-01
... natural wine from juice having a fixed acid level exceeding 5.0 grams per liter, the winemaker may adjust... acid level of the juice or wine by 0.1 gram per liter (the fixed acid level of the juice or wine may not be less than 5.0 gram per liter after the addition of ameliorating material). (b) Limitations. (1...
Code of Federal Regulations, 2013 CFR
2013-04-01
... natural wine from juice having a fixed acid level exceeding 5.0 grams per liter, the winemaker may adjust... acid level of the juice or wine by 0.1 gram per liter (the fixed acid level of the juice or wine may not be less than 5.0 gram per liter after the addition of ameliorating material). (b) Limitations. (1...
Manufacturing Precise, Lightweight Paraboloidal Mirrors
NASA Technical Reports Server (NTRS)
Hermann, Frederick Thomas
2006-01-01
A process for fabricating a precise, diffraction- limited, ultra-lightweight, composite- material (matrix/fiber) paraboloidal telescope mirror has been devised. Unlike the traditional process of fabrication of heavier glass-based mirrors, this process involves a minimum of manual steps and subjective judgment. Instead, this process involves objectively controllable, repeatable steps; hence, this process is better suited for mass production. Other processes that have been investigated for fabrication of precise composite-material lightweight mirrors have resulted in print-through of fiber patterns onto reflecting surfaces, and have not provided adequate structural support for maintenance of stable, diffraction-limited surface figures. In contrast, this process does not result in print-through of the fiber pattern onto the reflecting surface and does provide a lightweight, rigid structure capable of maintaining a diffraction-limited surface figure in the face of changing temperature, humidity, and air pressure. The process consists mainly of the following steps: 1. A precise glass mandrel is fabricated by conventional optical grinding and polishing. 2. The mandrel is coated with a release agent and covered with layers of a carbon- fiber composite material. 3. The outer surface of the outer layer of the carbon-fiber composite material is coated with a surfactant chosen to provide for the proper flow of an epoxy resin to be applied subsequently. 4. The mandrel as thus covered is mounted on a temperature-controlled spin table. 5. The table is heated to a suitable temperature and spun at a suitable speed as the epoxy resin is poured onto the coated carbon-fiber composite material. 6. The surface figure of the optic is monitored and adjusted by use of traditional Ronchi, Focault, and interferometric optical measurement techniques while the speed of rotation and the temperature are adjusted to obtain the desired figure. The proper selection of surfactant, speed or rotation, viscosity of the epoxy, and temperature make it possible to obtain the desired diffraction-limited, smooth (1/50th wave) parabolic outer surface, suitable for reflective coating. 7. A reflective coat is applied by use of conventional coating techniques. 8. Once the final figure is set, a lightweight structural foam is applied to the rear of the optic to ensure stability of the figure.
NASA Technical Reports Server (NTRS)
Hansen, Timothy D.; Bardwell, Micheal J.
1996-01-01
Portable spray booth provides for controlled application of coating materials with high solvent contents. Includes contoured shroud and carbon filter bed limiting concentration of fumes in vicinity. Designed to substitute spraying for brush application of solvent-based adhesive prior to installing rubber waterproof seals over joints between segments of solid-fuel rocket motor. With minor adjustments and modifications, used to apply other solvent-based adhesives, paints, and like.
7 CFR 701.17 - Average adjusted gross income limitation.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 7 2010-01-01 2010-01-01 false Average adjusted gross income limitation. 701.17... RELATED PROGRAMS PREVIOUSLY ADMINISTERED UNDER THIS PART § 701.17 Average adjusted gross income limitation... 9003), each applicant must meet the provisions of the Adjusted Gross Income Limitations at 7 CFR part...
Adjustable-Pressure Mandrel For Making Composite Tubes
NASA Technical Reports Server (NTRS)
Jacoy, Paul J.; Schmitigal, Wesley P.
1993-01-01
Inflatable inner mandrel enables application of any desired pressure (within reasonable limits) during curing stage in fabrication of fiber/matrix composite tube. Consists mainly of sheath of silicone rubber sealed on aluminum tube. Composite material laid up on mandrel and enclosed in rigid outer die. Sheath on inner mandrel inflated to requisite pressure and regulated during curing. Assembly then placed in oven and cured at specified temperature.
7 CFR 701.117 - Average adjusted gross income limitation.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 7 2011-01-01 2011-01-01 false Average adjusted gross income limitation. 701.117... Conservation Program § 701.117 Average adjusted gross income limitation. To be eligible for payments issued... the provisions of the Adjusted Gross Income Limitations at 7 CFR part 1400 subpart G. [72 FR 45880...
15 CFR 6.3 - Limitation on First Adjustments.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Limitation on First Adjustments. 6.3 Section 6.3 Commerce and Foreign Trade Office of the Secretary of Commerce CIVIL MONETARY PENALTY INFLATION ADJUSTMENTS § 6.3 Limitation on First Adjustments. Each of the First Adjustments may not exceed...
Fixture for supporting and aligning a sample to be analyzed in an x-ray diffraction apparatus
Green, L.A.; Heck, J.L. Jr.
1985-04-23
A fixture is provided for supporting and aligning small samples of material on a goniometer for x-ray diffraction analysis. A sample-containing capillary is accurately positioned for rotation in the x-ray beam by selectively adjusting the fixture to position the capillary relative to the x and y axes thereof to prevent wobble and position the sample along the z axis or the axis of rotation. By employing the subject fixture relatively small samples of materials can be analyzed in an x-ray diffraction apparatus previously limited to the analysis of much larger samples.
Fixture for supporting and aligning a sample to be analyzed in an X-ray diffraction apparatus
Green, Lanny A.; Heck, Jr., Joaquim L.
1987-01-01
A fixture is provided for supporting and aligning small samples of material on a goniometer for X-ray diffraction analysis. A sample-containing capillary is accurately positioned for rotation in the X-ray beam by selectively adjusting the fixture to position the capillary relative to the x and y axes thereof to prevent wobble and position the sample along the z axis or the axis of rotation. By employing the subject fixture relatively small samples of materials can be analyzed in an X-ray diffraction apparatus previously limited to the analysis of much larger samples.
NASA Astrophysics Data System (ADS)
Salvini, A.; Cattadori, C.; Broggini, C.; Cagnazzo, M.; Ori, Gian Gabriele; Nisi, S.; Borio, A.; Manera, S.
2006-05-01
The platinum metals depleted in the earth's crust are relative to their cosmic abundance; concentration of these elements in sediments may thus indicate influxes of extraterrestrial material. Analysis of these parameters are done easily by Neutron Activation Analysis (NAA) and comparative results with ICP-MS technique show a good match. Results, adjust parameters and limits of this method will be displayed in tables.
Rheology of tissue conditioners.
Murata, H; Hamada, T; Djulaeha, E; Nikawa, H
1998-02-01
Tissue conditioners can be used to condition abused tissues, record functional impressions, make temporary relinings, and for other clinical applications, mainly because of their specific viscoelasticity. However, little information is available on the rheology of the materials, manipulation, and suitability for various clinical applications. This study evaluated the gelation times, the viscoelastic properties after gelation of tissue conditioners, and the influence of the powder/liquid (P/L) ratio. Ten tissue conditioners were used and gelation times were obtained with an oscillating rheometer. A series of stress relaxation tests were also conducted to evaluate the viscoelastic properties after gelation and the changes with the passage of time by means of Maxwell model analogies. Significant differences were found in the gelation times and flow properties after gelation among the materials mixed with the P/L ratios recommended by the manufacturers. The flow properties tended to increase with time of storage. Large differences in the limits of the clinically acceptable P/L ratios and the adjustable limits of elasticity and viscosity by altering P/L ratios were found among the materials. The results suggested that each material should be selected according to each clinical purpose because of the wide ranges of viscoelastic properties and changes in viscoelasticity with time among the materials. Furthermore, gelation times and the viscoelastic properties after gelation can be controlled to improve handling and suit various applications by altering the P/L ratios within the acceptable limits.
Embracing additive manufacture: implications for foot and ankle orthosis design
2012-01-01
Background The design of foot and ankle orthoses is currently limited by the methods used to fabricate the devices, particularly in terms of geometric freedom and potential to include innovative new features. Additive manufacturing (AM) technologies, where objects are constructed via a series of sub-millimetre layers of a substrate material, may present the opportunity to overcome these limitations and allow novel devices to be produced that are highly personalised for the individual, both in terms of fit and functionality. Two novel devices, a foot orthosis (FO) designed to include adjustable elements to relieve pressure at the metatarsal heads, and an ankle foot orthosis (AFO) designed to have adjustable stiffness levels in the sagittal plane, were developed and fabricated using AM. The devices were then tested on a healthy participant to determine if the intended biomechanical modes of action were achieved. Results The adjustable, pressure relieving FO was found to be able to significantly reduce pressure under the targeted metatarsal heads. The AFO was shown to have distinct effects on ankle kinematics which could be varied by adjusting the stiffness level of the device. Conclusions The results presented here demonstrate the potential design freedom made available by AM, and suggest that it may allow novel personalised orthotic devices to be produced which are beyond the current state of the art. PMID:22642941
39 CFR 3010.25 - Limitation on unused rate adjustment authority rate adjustments.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 39 Postal Service 1 2010-07-01 2010-07-01 false Limitation on unused rate adjustment authority rate adjustments. 3010.25 Section 3010.25 Postal Service POSTAL REGULATORY COMMISSION PERSONNEL REGULATION OF RATES FOR MARKET DOMINANT PRODUCTS Rules for Applying the Price Cap § 3010.25 Limitation on...
Steve Verrill; David Kretschmann
2008-01-01
It has been argued that repetitive member allowable property adjustments should be larger for high-variability material than for low-variability material. We report analytic calculations and simulations that suggest that the order of such adjustments should be reversed. That is, given the manner in which allowable properties are currently calculated, as the coefficient...
Acoustic sensor for real-time control for the inductive heating process
Kelley, John Bruce; Lu, Wei-Yang; Zutavern, Fred J.
2003-09-30
Disclosed is a system and method for providing closed-loop control of the heating of a workpiece by an induction heating machine, including generating an acoustic wave in the workpiece with a pulsed laser; optically measuring displacements of the surface of the workpiece in response to the acoustic wave; calculating a sub-surface material property by analyzing the measured surface displacements; creating an error signal by comparing an attribute of the calculated sub-surface material properties with a desired attribute; and reducing the error signal below an acceptable limit by adjusting, in real-time, as often as necessary, the operation of the inductive heating machine.
The Case for Intelligent Propulsion Control for Fast Engine Response
NASA Technical Reports Server (NTRS)
Litt, Jonathan S.; Frederick, Dean K.; Guo, Ten-Huei
2009-01-01
Damaged aircraft have occasionally had to rely solely on thrust to maneuver as a consequence of losing hydraulic power needed to operate flight control surfaces. The lack of successful landings in these cases inspired research into more effective methods of utilizing propulsion-only control. That research demonstrated that one of the major contributors to the difficulty in landing is the slow response of the engines as compared to using traditional flight control. To address this, research is being conducted into ways of making the engine more responsive under emergency conditions. This can be achieved by relaxing controller limits, adjusting schedules, and/or redesigning the regulators to increase bandwidth. Any of these methods can enable faster response at the potential expense of engine life and increased likelihood of stall. However, an example sensitivity analysis revealed a complex interaction of the limits and the difficulty in predicting the way to achieve the fastest response. The sensitivity analysis was performed on a realistic engine model, and demonstrated that significantly faster engine response can be achieved compared to standard Bill of Material control. However, the example indicates the need for an intelligent approach to controller limit adjustment in order for the potential to be fulfilled.
Zinc peroxide nanomaterial as an adsorbent for removal of Congo red dye from waste water.
Chawla, Sneha; Uppal, Himani; Yadav, Mohit; Bahadur, Nupur; Singh, Nahar
2017-01-01
In the past decade, various natural byproducts, advanced metal oxide composites and photocatalysts have been reported for removal of dyes from water. Although these materials are useful for select applications, they have some limitations such as use at fixed temperature, ultra violet (UV) light and the need for sophisticated experimental set up. These materials can remove dyes up to a certain extent but require long time. To overcome these limitations, a promising adsorbent zinc peroxide (ZnO 2 ) nanomaterial has been developed for the removal of Congo red (CR) dye from contaminated water. ZnO 2 is highly efficient even in the absence of sunlight to remove CR from contaminated water upto the permissible limits set by the World Health Organization (WHO) and the United States- Environmental Protection Agency (US-EPA). The adsorbent has a specific property to adjust the pH of the test solution within 6.5-7.5 range irrespective of acidic or basic nature of water. The adsorption capacity of the material for CR dye was 208mgg -1 within 10min at 2-10pH range. The proposed material could be useful for the industries involved in water purification. The removal of CR has been confirmed by spectroscopic and microscopic techniques. The adsorption data followed a second order kinetics and Freundlich isotherm. Copyright © 2016 Elsevier Inc. All rights reserved.
Measured moisture in buildings and adverse health effects: A review.
Mendell, M J; Macher, J M; Kumagai, K
2018-04-23
It has not yet been possible to quantify dose-related health risks attributable to indoor dampness or mold (D/M), to support setting specific health-related limits for D/M. An overlooked target for assessing D/M is moisture in building materials, the critical factor allowing microbial growth. A search for studies of quantified building moisture and occupant health effects identified 3 eligible studies. Two studies assessed associations between measured wall moisture content and respiratory health in the UK. Both reported dose-related increases in asthma exacerbation with higher measured moisture, with 1 study reporting an adjusted odds ratio of 7.0 for night-time asthma symptoms with higher bedroom moisture. The third study assessed relationships between infrared camera-determined wall moisture and atopic dermatitis in South Korea, reporting an adjusted odds ratio of 14.5 for water-damaged homes and moderate or severe atopic dermatitis. Measuring building moisture has, despite extremely limited available findings, potential promise for detecting unhealthy D/M in homes and merits more research attention. Further research to validate these findings should include measured "water activity," which directly assesses moisture availability for microbial growth. Ultimately, evidence-based, health-related thresholds for building moisture, across specific materials and measurement devices, could better guide assessment and remediation of D/M in buildings. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
A closed loop process for recycling spent lithium ion batteries
NASA Astrophysics Data System (ADS)
Gratz, Eric; Sa, Qina; Apelian, Diran; Wang, Yan
2014-09-01
As lithium ion (Li-ion) batteries continue to increase their market share, recycling Li-ion batteries will become mandatory due to limited resources. We have previously demonstrated a new low temperature methodology to separate and synthesize cathode materials from mixed cathode materials. In this study we take used Li-ion batteries from a recycling source and recover active cathode materials, copper, steel, etc. To accomplish this the batteries are shredded and processed to separate the steel, copper and cathode materials; the cathode materials are then leached into solution; the concentrations of nickel, manganese and cobalt ions are adjusted so NixMnyCoz(OH)2 is precipitated. The precipitated product can then be reacted with lithium carbonate to form LiNixMnyCozO2. The results show that the developed recycling process is practical with high recovery efficiencies (∼90%), and 1 ton of Li-ion batteries has the potential to generate 5013 profit margin based on materials balance.
Actively adjustable step-type ultrasonic horns in longitudinal vibration
NASA Astrophysics Data System (ADS)
Lin, Shuyu; Guo, Hao; Xu, Jie
2018-04-01
Actively adjustable longitudinal step-type ultrasonic horns are proposed and studied. The horn is composed of a traditional ultrasonic horn and piezoelectric material. In practical applications, this kind of step-type ultrasonic horn is mechanically excited by an ultrasonic transducer and the piezoelectric material is connected to an adjustable electric impedance. In this research, the effects of the electric impedance and of the location of the piezoelectric material on the performance of the horn are studied. It is shown that when the electric resistance is increased, the resonance frequency of the horn is increased; the displacement magnification is increased when the piezoelectric material is located in the large end and decreased when the piezoelectric material is located in the small end of the horn. The displacement magnification for the piezoelectric material in the large end is larger than that for the piezoelectric material in the small end of the horn. Some step-type ultrasonic horns are designed and manufactured; the resonance frequency and the displacement magnification are measured by means of POLYTEC Laser Scanning vibrometer. It is shown that the theoretical resonance frequency and the displacement magnification are in good agreement with the measured results. It is concluded that by means of the insertion of the piezoelectric material in the longitudinal horn, the horn performance can be adjusted by changing the electric impedance and the location of the piezoelectric material in the horn. It is expected that this kind of adjustable ultrasonic horns can be used in traditional and potential ultrasonic technologies where the vibrational performance adjustment is needed.
Erratum to: Application of addition-cured silicone denture relining materials to adjust mouthguards.
Fukasawa, Shintaro; Churei, Hiroshi; Chowdhury, Ruman Uddin; Shirako, Takahiro; Shahrin, Sharika; Shrestha, Abhishekhi; Wada, Takahiro; Uo, Motohiro; Takahashi, Hidekazu; Ueno, Toshiaki
2016-01-01
The purposes of this study were to examine the shock absorption capability of addition-cured silicone denture relining materials and the bonding strength of addition-cured silicone denture relining materials and a commercial mouthguard material to determine its applicability to mouthguard adjustment. Two addition-cured silicone denture relining materials were selected as test materials. The impact test was applied by a free-falling steel ball. On the other hand, bonding strength was determined by a delamination test. After prepared surface treatments using acrylic resin on MG sheet surface, 2 types of addition-cured silicone denture relining materials were glued to MG surface. The peak intensity, the time to peak intensity from the onset of the transmitted force and bonding strength were statistically analyzed using ANOVA and Tukey's honest significant difference post hoc test (p<0.05). These results suggest that the silicone denture relining materials could be clinically applicable as a mouthguard adjustment material.
Simon, Andrew; Thorne, Colin R.
1996-01-01
Channel adjustments in the North Fork Toutle River and the Toutle River main stem were initiated by deposition of a 2.5km3 debris avalanche and associated lahars that accompanied the catastrophic eruption of Mount St. Helens, Washington on 18 May 1980. Channel widening was the dominant process. In combination, adjustments caused average boundary shear stress to decrease non-linearly with time and critical shear stress to increase non-linearly with time. At the discharge that is equalled or exceeded 1 per cent of the time, these trends converged by 1991-1992 so that excess shear stress approached minimum values. Extremal hypotheses, such as minimization of unit stream power and minimization of the rate of energy dissipation (minimum stream power), are shown to be applicable to dynamic adjustments of the Toutle River system. Maximization of the Darcy-Weisbach friction factor did not occur, but increases in relative bed roughness, caused by the concomitant reduction in hydraulic depths and bed-material coarsening, were documented. Predictions of stable channel geometries using the minimum stream power approach were unsuccessful when compared to the 1991-1992 geometries and bed-material characteristics measured in the field. It is concluded that the predictions are not applicable because the study reaches are not truly stable and cannot become so until a new floodplain has been formed by renewed channel incision, retreat of stream-side hummocks, and establishment of riparian vegetation to limit the destabilizing effects of large floods. Further, prediction of energy slope (and consequently stream power) by the sediment transport equations is inaccurate because of the inability of the equations to account for significant contributions of finer grained (sand and gravel) bank materials (relative to the coarsened channel bed) from bank retreat and from upstream terrace erosion.
Novick, Richard J; Fox, Stephanie A; Stitt, Larry W; Forbes, Thomas L; Steiner, Stefan
2006-08-01
We previously applied non-risk-adjusted cumulative sum methods to analyze coronary bypass outcomes. The objective of this study was to assess the incremental advantage of risk-adjusted cumulative sum methods in this setting. Prospective data were collected in 793 consecutive patients who underwent coronary bypass grafting performed by a single surgeon during a period of 5 years. The composite occurrence of an "adverse outcome" included mortality or any of 10 major complications. An institutional logistic regression model for adverse outcome was developed by using 2608 contemporaneous patients undergoing coronary bypass. The predicted risk of adverse outcome in each of the surgeon's 793 patients was then calculated. A risk-adjusted cumulative sum curve was then generated after specifying control limits and odds ratio. This risk-adjusted curve was compared with the non-risk-adjusted cumulative sum curve, and the clinical significance of this difference was assessed. The surgeon's adverse outcome rate was 96 of 793 (12.1%) versus 270 of 1815 (14.9%) for all the other institution's surgeons combined (P = .06). The non-risk-adjusted curve reached below the lower control limit, signifying excellent outcomes between cases 164 and 313, 323 and 407, and 667 and 793, but transgressed the upper limit between cases 461 and 478. The risk-adjusted cumulative sum curve never transgressed the upper control limit, signifying that cases preceding and including 461 to 478 were at an increased predicted risk. Furthermore, if the risk-adjusted cumulative sum curve was reset to zero whenever a control limit was reached, it still signaled a decrease in adverse outcome at 166, 653, and 782 cases. Risk-adjusted cumulative sum techniques provide incremental advantages over non-risk-adjusted methods by not signaling a decrement in performance when preoperative patient risk is high.
Computational material design for Q&P steels with plastic instability theory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, G.; Choi, K. S.; Hu, X. H.
In this paper, the deformation limits of Quenching and Partitioning (Q&P) steels are examined with the plastic instability theory. For this purpose, the constituent phase properties of various Q&P steels were first experimentally obtained, and used to estimate the overall tensile stress-strain curves based on the simple rule of mixture (ROM) with the iso-strain and iso-stress assumptions. Plastic instability theory was then applied to the obtained overall stress-strain curves in order to estimate the deformation limits of the Q&P steels. A parametric study was also performed to examine the effects of various material parameters on the deformation limits of Q&Pmore » steels. Computational material design was subsequently carried out based on the information obtained from the parametric study. The results show that the plastic instability theory with iso-stress-based stress-strain curve may be used to provide the lower bound estimate of the uniform elongation (UE) for the various Q&P steels considered. The results also indicate that higher austenite stability/volume fractions, less strength difference between the primary phases, higher hardening exponents of the constituent phases are generally beneficial for the performance improvement of Q&P steels, and that various material parameters may be concurrently adjusted in a cohesive way in order to improve the performance of Q&P steel. The information from this study may be used to devise new heat treatment parameters and alloying elements to produce Q&P steels with the improved performance.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-25
...; Adjustment to the Atlantic Herring Management Area 1A Sub- Annual Catch Limit AGENCY: National Marine...: Temporary rule; inseason adjustment. SUMMARY: NMFS adjusts the 2011 Fishing Year sub-annual catch limit for... transfer and sub-ACLs for each management area. The 2011 Domestic Annual Harvest is 91,200 metric tons (mt...
Tolerance limit value of brightness and contrast adjustment on digitized radiographs
NASA Astrophysics Data System (ADS)
Utami, S. N.; Kiswanjaya, B.; Syahraini, S. I.; Ustriyana, P.
2017-08-01
The aim of this study was to measure the tolerance limit value of brightness and contrast adjustment on digitized radiograph with apical periodontitis and early apical abscess. Brightness and contrast adjustment on 60 periapical radiograph with apical periodontitis and early apical abscess made by 2 observers. Reliabilities tested by Cohen’s Kappa Coefficient and significance tested by wilcoxon test. Tolerance limit value of brightness and contrast adjustment for apical periodontitis is -5 and +5, early apical abscess is -10 and +10, and both is -5 and +5. Brightness and contrast adjustment which not appropriate can alter the evaluation and differential diagnosis of periapical lesion.
Application of addition-cured silicone denture relining materials to adjust mouthguards.
Fukasawa, Shintaro; Churei, Hiroshi; Chowdhury, Ruman Uddin; Shirako, Takahiro; Shahrin, Sharika; Shrestha, Abhishekhi; Wada, Takahiro; Uo, Motohiro; Takahashi, Hidekazu; Ueno, Toshiaki
2016-01-01
The purposes of this study were to examine the shock absorption capability of addition-cured silicone denture relining materials and the bonding strength of addition-cured silicone denture relining materials and a commercial mouthguard material to determine its applicability to mouthguard adjustment. Two addition-cured silicone denture relining materials and eleven commercial mouthguard materials were selected as test materials. The impact test was applied by a free-falling steel ball. On the other hand, bonding strength was determined by a delamination test. After prepared surface treatments using acrylic resin on MG sheet surface, 2 types of addition-cured silicone denture relining materials were glued to MG surface. The peak intensity, the time to peak intensity from the onset of the transmitted force and bonding strength were statistically analyzed using ANOVA and Tukey's honest significant difference post hoc test (p<0.05). These results suggest that the silicone denture relining materials could be clinically applicable as a mouthguard adjustment material.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-29
... 1A sub-ACL. Classification This action is required by 50 CFR part 648 and is exempt from review under...; Adjustment to the Atlantic Herring Management Area 1A Sub- Annual Catch Limit AGENCY: National Marine...: Temporary rule; inseason adjustment. SUMMARY: NMFS adjusts the 2012 fishing year sub-annual catch limit for...
Tunable surface plasmon devices
Shaner, Eric A [Rio Rancho, NM; Wasserman, Daniel [Lowell, MA
2011-08-30
A tunable extraordinary optical transmission (EOT) device wherein the tunability derives from controlled variation of the dielectric constant of a semiconducting material (semiconductor) in evanescent-field contact with a metallic array of sub-wavelength apertures. The surface plasmon resonance wavelength can be changed by changing the dielectric constant of the dielectric material. In embodiments of this invention, the dielectric material is a semiconducting material. The dielectric constant of the semiconducting material in the metal/semiconductor interfacial region is controllably adjusted by adjusting one or more of the semiconductor plasma frequency, the concentration and effective mass of free carriers, and the background high-frequency dielectric constant in the interfacial region. Thermal heating and/or voltage-gated carrier-concentration changes may be used to variably adjust the value of the semiconductor dielectric constant.
Covalent adaptable networks: smart, reconfigurable and responsive network systems.
Kloxin, Christopher J; Bowman, Christopher N
2013-09-07
Covalently crosslinked materials, classically referred to as thermosets, represent a broad class of elastic materials that readily retain their shape and molecular architecture through covalent bonds that are ubiquitous throughout the network structure. These materials, in particular in their swollen gel state, have been widely used as stimuli responsive materials with their ability to change volume in response to changes in temperature, pH, or other solvent conditions and have also been used in shape memory applications. However, the existence of a permanent, unalterable shape and structure dictated by the covalently crosslinked structure has dramatically limited their abilities in this and many other areas. These materials are not generally reconfigurable, recyclable, reprocessable, and have limited ability to alter permanently their stress state, topography, topology, or structure. Recently, a new paradigm has been explored in crosslinked polymers - that of covalent adaptable networks (CANs) in which covalently crosslinked networks are formed such that triggerable, reversible chemical structures persist throughout the network. These reversible covalent bonds can be triggered through molecular triggers, light or other incident radiation, or temperature changes. Upon application of this stimulus, rather than causing a temporary shape change, the CAN structure responds by permanently adjusting its structure through either reversible addition/condensation or through reversible bond exchange mechanisms, either of which allow the material to essentially reequilibrate to its new state and condition. Here, we provide a tutorial review on these materials and their responsiveness to applied stimuli. In particular, we review the broad classification of these materials, the nature of the chemical bonds that enable the adaptable structure, how the properties of these materials depend on the reversible structure, and how the application of a stimulus causes these materials to alter their shape, topography, and properties.
7 CFR 1400.502 - Compliance and enforcement.
Code of Federal Regulations, 2011 CFR
2011-01-01
... AND SUBSEQUENT CROP, PROGRAM, OR FISCAL YEARS Average Adjusted Gross Income Limitation § 1400.502 Compliance and enforcement. (a) To comply with the average adjusted gross income limitation, a person or... CCC from a certified public accountant or attorney that the average adjusted gross income of the...
13 CFR 315.16 - Adjustment proposal requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... OF COMMERCE TRADE ADJUSTMENT ASSISTANCE FOR FIRMS Adjustment Proposals § 315.16 Adjustment proposal... reasonably calculated to contribute materially to the economic adjustment of the Firm (i.e., that such... generally consists of knowledge-based services such as market penetration studies, customized business...
Localized electrical fine tuning of passive microwave and radio frequency devices
Findikoglu, Alp T.
2001-04-10
A method and apparatus for the localized electrical fine tuning of passive multiple element microwave or RF devices in which a nonlinear dielectric material is deposited onto predetermined areas of a substrate containing the device. An appropriate electrically conductive material is deposited over predetermined areas of the nonlinear dielectric and the signal line of the device for providing electrical contact with the nonlinear dielectric. Individual, adjustable bias voltages are applied to the electrically conductive material allowing localized electrical fine tuning of the devices. The method of the present invention can be applied to manufactured devices, or can be incorporated into the design of the devices so that it is applied at the time the devices are manufactured. The invention can be configured to provide localized fine tuning for devices including but not limited to coplanar waveguides, slotline devices, stripline devices, and microstrip devices.
Methyl methacrylate as a healing agent for self-healing cementitious materials
NASA Astrophysics Data System (ADS)
Van Tittelboom, K.; Adesanya, K.; Dubruel, P.; Van Puyvelde, P.; De Belie, N.
2011-12-01
Different types of healing agents have already been tested on their efficiency for use in self-healing cementitious materials. Generally, commercial healing agents are used while their properties are adjusted for manual crack repair and not for autonomous crack healing. Consequently, the amount of regain in properties due to self-healing of cracks is limited. In this research, a methyl methacrylate (MMA)-based healing agent was developed specifically for use in self-healing cementitious materials. Various parameters were optimized including the viscosity, curing time, strength, etc. After the desired properties were obtained, the healing agent was encapsulated and screened for its self-healing efficiency. The decrease in water permeability due to autonomous crack healing using MMA as a healing agent was similar to the results obtained for manually healed cracks. First results seem promising: however, further research needs to be undertaken in order to obtain an optimal healing agent ready for use in practice.
Perovskite- and Heusler based materials for thermoelectric converters
NASA Astrophysics Data System (ADS)
Weidenkaff, Anke
2015-03-01
The broad application of thermoelectric converters in future energy technologies requires the development of active, stable, low cost and sustainable materials. Semiconductors based on perovskite and heusler structures show substantial potential for thermoelectric energy conversion processes. Their good performance can be explained based on their suitable band structure, adjusted charge carrier density, mass and mobility, limited phonon transport, electron filtering possibilities, strongly correlated electronic systems, etc. These properties are widely tuneable by following theoretical concepts and a deep composition-structure-property understanding to change the composition, structure and size of the crystallites in innovative scalable synthesis procedures. Improved thermoelectric materials are developed, synthesised and tested in diverse high temperature applications to improve the efficiency and energy density of the thermoelectric conversion process. The lecture will provide a summary on the field of advanced perovskite-type ceramics and Heusler compounds gaining importance for a large number of future energy technologies.
Steve Verrill; David E. Kretschmann
2009-01-01
It has been argued that repetitive member allowable property adjustments should be larger for high-variability materials than for low-variability materials. We report analytic calculations and simulations that suggest that the order of such adjustments should be reversed, that is, given the manner in which allowable properties are currently calculated, as the...
Cost Indexing and Unit Price Adjustments for Construction Materials
DOT National Transportation Integrated Search
2012-10-30
This project was focused on the assimilation of information regarding unit price adjustment clauses, or PACs, : that are offered for construction materials at the state Departments of Transportation (DOTs). It is intended to : provide the South Carol...
Cumulative hardship and wellness of low-income, young children: multisite surveillance study.
Frank, Deborah A; Casey, Patrick H; Black, Maureen M; Rose-Jacobs, Ruth; Chilton, Mariana; Cutts, Diana; March, Elizabeth; Heeren, Timothy; Coleman, Sharon; de Cuba, Stephanie Ettinger; Cook, John T
2010-05-01
The goals were to generate a cumulative hardship index and to evaluate its association with the well-being of children 4 to 36 months of age without private health insurance. Cross-sectional surveys were linked to anthropometric measures and medical record review at 5 urban medical centers (July 1, 2004, to December 31, 2007). Cumulative hardship index scores ranged from 0 to 6, with food, housing, and energy each contributing a possible score of 0 (secure), 1 (moderately insecure), or 2 (severely insecure) to generate scores indicating no hardship (score of 0), moderate hardship (scores of 1-3), or severe hardship (scores of 4-6). The outcome was a composite indicator of child wellness, including caregivers' reports of children's good/excellent heath, no hospitalizations, not being developmentally at risk, and anthropometric measurements within normal limits. Covariates were selected a priori and through association with predictors and outcomes. Of 7141 participants, 37% reported no material hardship, 57% moderate hardship, and 6% severe hardship. Multivariate logistic regression analyses showed ordinal association between the cumulative hardship index and children's adjusted odds of wellness (severe versus no hardship, adjusted odds ratio [AOR]: 0.65 [95% confidence interval [CI]: 0.51-0.83]; severe versus moderate hardship, AOR: 0.73 [95% CI: 0.58-0.92]; moderate versus no hardship, AOR: 0.89 [95% CI: 0.79-0.99]). Increasing levels of a composite measure of remediable adverse material conditions correlated with decreasing adjusted odds of wellness among young US children.
Authentication via wavefront-shaped optical responses
NASA Astrophysics Data System (ADS)
Eilers, Hergen; Anderson, Benjamin R.; Gunawidjaja, Ray
2018-02-01
Authentication/tamper-indication is required in a wide range of applications, including nuclear materials management and product counterfeit detection. State-of-the-art techniques include reflective particle tags, laser speckle authentication, and birefringent seals. Each of these passive techniques has its own advantages and disadvantages, including the need for complex image comparisons, limited flexibility, sensitivity to environmental conditions, limited functionality, etc. We have developed a new active approach to address some of these short-comings. The use of an active characterization technique adds more flexibility and additional layers of security over current techniques. Our approach uses randomly-distributed nanoparticles embedded in a polymer matrix (tag/seal) which is attached to the item to be secured. A spatial light modulator is used to adjust the wavefront of a laser which interacts with the tag/seal, and a detector is used to monitor this interaction. The interaction can occur in various ways, including transmittance, reflectance, fluorescence, random lasing, etc. For example, at the time of origination, the wavefront-shaped reflectance from a tag/seal can be adjusted to result in a specific pattern (symbol, words, etc.) Any tampering with the tag/seal would results in a disturbance of the random orientation of the nanoparticles and thus distort the reflectance pattern. A holographic waveplate could be inserted into the laser beam for verification. The absence/distortion of the original pattern would then indicate that tampering has occurred. We have tested the tag/seal's and authentication method's tamper-indicating ability using various attack methods, including mechanical, thermal, and chemical attacks, and have verified our material/method's robust tamper-indicating ability.
7 CFR 1400.503 - Commensurate reduction.
Code of Federal Regulations, 2011 CFR
2011-01-01
... AND SUBSEQUENT CROP, PROGRAM, OR FISCAL YEARS Average Adjusted Gross Income Limitation § 1400.503... legal entity determined to have an average adjusted gross income in excess of the applicable limitation...
7 CFR 1400.503 - Commensurate reduction.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND SUBSEQUENT CROP, PROGRAM, OR FISCAL YEARS Average Adjusted Gross Income Limitation § 1400.503... legal entity determined to have an average adjusted gross income in excess of the applicable limitation...
Adjustable knife cuts honeycomb material to specified depth
NASA Technical Reports Server (NTRS)
Rauschl, J. A.
1966-01-01
Calibrated, adjustable knife cuts aluminum honeycomb or other soft materials to a desired depth. The frame of the device accommodates standard commercial blades. Since the blade is always visible to the operator, the device can be used on any straight or irregular layout line.
Effects of Increased Loading on In Vivo Tendon Properties: A Systematic Review
WIESINGER, HANS-PETER; KÖSTERS, ALEXANDER; MÜLLER, ERICH; SEYNNES, OLIVIER R.
2015-01-01
ABSTRACT Introduction In vivo measurements have been used in the past two decades to investigate the effects of increased loading on tendon properties, yet the current understanding of tendon macroscopic changes to training is rather fragmented, limited to reports of tendon stiffening, supported by changes in material properties and/or tendon hypertrophy. The main aim of this review was to analyze the existing literature to gain further insights into tendon adaptations by extracting patterns of dose-response and time-course. Methods PubMed/Medline, SPORTDiscus, and Google Scholar databases were searched for studies examining the effect of training on material, mechanical, and morphological properties via longitudinal or cross-sectional designs. Results Thirty-five of 6440 peer-reviewed articles met the inclusion criteria. The key findings were i) the confirmation of a nearly systematic adaptation of tendon tissue to training, ii) the important variability in the observed changes in tendon properties between and within studies, and iii) the absence of a consistent incremental pattern regarding the dose-response or the time-course relation of tendon adaptation within the first months of training. However, long-term (years) training was associated with a larger tendon cross-sectional area, without any evidence of differences in material properties. Our analysis also highlighted several gaps in the existing literature, which may be addressed in future research. Conclusions In line with some cross-species observations about tendon design, tendon cross-sectional area allegedly constitutes the ultimate adjusting parameter to increased loading. We propose here a theoretical model placing tendon hypertrophy and adjustments in material properties as parts of the same adaptive continuum. PMID:25563908
THE PLANTER--SELECTION, ADJUSTMENT, MAINTENANCE, AND USE.
ERIC Educational Resources Information Center
Illinois Univ., Urbana. Coll. of Agriculture.
RESOURCE MATERIAL ON CORN PLANTERS FOR USE IN HIGH SCHOOL VOCATIONAL AGRICULTURE AND ADULT FARMER CLASSES WAS DESIGNED BY SUBJECT MATTER SPECIALISTS, TEACHER EDUCATORS, SUPERVISORS, AND TEACHERS TO PROVIDE TEXTUAL MATERIAL FOR STUDENTS ON THE SELECTION, OPERATION, ADJUSTMENT, USE, MAINTENANCE, AND PRACTICAL APPLICATION OF CORN PLANTERS. THE…
Translucency of human teeth and dental restorative materials and its clinical relevance
NASA Astrophysics Data System (ADS)
Lee, Yong-Keun
2015-04-01
The purpose was to review the translucency of human teeth and related dental materials that should be considered for the development of esthetic restorative materials. Translucency is the relative amount of light transmission or diffuse reflection from a substrate surface through a turbid medium. Translucency influences the masking ability, color blending effect, and the degree of light curing through these materials. Regarding the translucency indices, transmission coefficient, translucency parameter, and contrast ratio have been used, and correlations among these indices were confirmed. Translucency of human enamel and dentine increases in direct proportion to the wavelength of incident light in the visible light range. As for the translucency changes by aging, limited differences were reported in human dentine, while those for enamel proved to increase. There have been studies for the adjustment of translucency in dental esthetic restorative materials; the size and amount of filler and the kind of resin matrix were modified in resin composites, and the kind of ingredient and the degree of crystallization were modified in ceramics. Based on the translucency properties of human enamel and dentine, those of replacing restorative materials should be optimized for successful esthetic rehabilitation. Biomimetic simulation of the natural tooth microstructure might be a promising method.
NASA Astrophysics Data System (ADS)
Rong, J. H.; Yi, J. H.
2010-10-01
In density-based topological design, one expects that the final result consists of elements either black (solid material) or white (void), without any grey areas. Moreover, one also expects that the optimal topology can be obtained by starting from any initial topology configuration. An improved structural topological optimization method for multi- displacement constraints is proposed in this paper. In the proposed method, the whole optimization process is divided into two optimization adjustment phases and a phase transferring step. Firstly, an optimization model is built to deal with the varied displacement limits, design space adjustments, and reasonable relations between the element stiffness matrix and mass and its element topology variable. Secondly, a procedure is proposed to solve the optimization problem formulated in the first optimization adjustment phase, by starting with a small design space and advancing to a larger deign space. The design space adjustments are automatic when the design domain needs expansions, in which the convergence of the proposed method will not be affected. The final topology obtained by the proposed procedure in the first optimization phase, can approach to the vicinity of the optimum topology. Then, a heuristic algorithm is given to improve the efficiency and make the designed structural topology black/white in both the phase transferring step and the second optimization adjustment phase. And the optimum topology can finally be obtained by the second phase optimization adjustments. Two examples are presented to show that the topologies obtained by the proposed method are of very good 0/1 design distribution property, and the computational efficiency is enhanced by reducing the element number of the design structural finite model during two optimization adjustment phases. And the examples also show that this method is robust and practicable.
Fast and Accurate Approximation to Significance Tests in Genome-Wide Association Studies
Zhang, Yu; Liu, Jun S.
2011-01-01
Genome-wide association studies commonly involve simultaneous tests of millions of single nucleotide polymorphisms (SNP) for disease association. The SNPs in nearby genomic regions, however, are often highly correlated due to linkage disequilibrium (LD, a genetic term for correlation). Simple Bonferonni correction for multiple comparisons is therefore too conservative. Permutation tests, which are often employed in practice, are both computationally expensive for genome-wide studies and limited in their scopes. We present an accurate and computationally efficient method, based on Poisson de-clumping heuristics, for approximating genome-wide significance of SNP associations. Compared with permutation tests and other multiple comparison adjustment approaches, our method computes the most accurate and robust p-value adjustments for millions of correlated comparisons within seconds. We demonstrate analytically that the accuracy and the efficiency of our method are nearly independent of the sample size, the number of SNPs, and the scale of p-values to be adjusted. In addition, our method can be easily adopted to estimate false discovery rate. When applied to genome-wide SNP datasets, we observed highly variable p-value adjustment results evaluated from different genomic regions. The variation in adjustments along the genome, however, are well conserved between the European and the African populations. The p-value adjustments are significantly correlated with LD among SNPs, recombination rates, and SNP densities. Given the large variability of sequence features in the genome, we further discuss a novel approach of using SNP-specific (local) thresholds to detect genome-wide significant associations. This article has supplementary material online. PMID:22140288
Latimer, Nicholas R; Abrams, Keith R; Lambert, Paul C; Crowther, Michael J; Wailoo, Allan J; Morden, James P; Akehurst, Ron L; Campbell, Michael J
2014-04-01
Treatment switching commonly occurs in clinical trials of novel interventions in the advanced or metastatic cancer setting. However, methods to adjust for switching have been used inconsistently and potentially inappropriately in health technology assessments (HTAs). We present recommendations on the use of methods to adjust survival estimates in the presence of treatment switching in the context of economic evaluations. We provide background on the treatment switching issue and summarize methods used to adjust for it in HTAs. We discuss the assumptions and limitations associated with adjustment methods and draw on results of a simulation study to make recommendations on their use. We demonstrate that methods used to adjust for treatment switching have important limitations and often produce bias in realistic scenarios. We present an analysis framework that aims to increase the probability that suitable adjustment methods can be identified on a case-by-case basis. We recommend that the characteristics of clinical trials, and the treatment switching mechanism observed within them, should be considered alongside the key assumptions of the adjustment methods. Key assumptions include the "no unmeasured confounders" assumption associated with the inverse probability of censoring weights (IPCW) method and the "common treatment effect" assumption associated with the rank preserving structural failure time model (RPSFTM). The limitations associated with switching adjustment methods such as the RPSFTM and IPCW mean that they are appropriate in different scenarios. In some scenarios, both methods may be prone to bias; "2-stage" methods should be considered, and intention-to-treat analyses may sometimes produce the least bias. The data requirements of adjustment methods also have important implications for clinical trialists.
Satsumoto, Yayoi
2012-06-01
The influence of the clothing material properties(like water absorbency and rapid dryness, water vapor absorption, water vapor permeability and air permeability) and the design factor of the clothing(like opening condition and fitting of clothing), which contributed to prevent heat disorder, was outlined. WBGT(wet-bulb globe temperature) is used to show a guideline for environmental limitation of activities to prevent heat disorder. As the safety function is more important than thermal comfort for some sportswear and protective clothing with high cover area, clothing itself increases the risk of heat disorder. WBGT is corrected by CAF (clothing adjustment factor) in wearing such kind of protective clothing.
Study on Material Selection of Reactor Pressure Vessel of SCWR
NASA Astrophysics Data System (ADS)
Ma, Shuli; Luo, Ying; Yin, Qinwei; Li, Changxiang; Xie, Guofu
This paper first analyzes the feasibility of SA-508 Grade 3 Class 1 Steel as an alternative material for Supercritical Water-Cooled Reactor (SCWR) Reactor Pressure Vessel (RPV). This kind of steel is limited to be applied in SCWR RPV due to its quenching property, though large forging could be accomplished by domestic manufacturers in forging aspect. Therefore, steels with higher strength and better quenching property are needed for SWCR RPV. The chemical component of SA-508 Gr.3 Cl.2 steel is similar to that of SA-508 Gr.3 Cl.1 steel, and more appropriate matching of strength and toughness could be achieved by the adjusting the elements contents, as well as proper control of tempering temperature and time. In light of the fact that Cl.2 steel has been successfully applied to steam generator, it could be an alternative material for SWCR RPV. SA-508 Gr.4N steel with high strength and good toughness is another alternative material for SCWR RPV. But large amount of research work before application is still needed for the lack of data on welding and irradiation etc.
48 CFR 52.216-4 - Economic Price Adjustment-Labor and Material.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false Economic Price Adjustment... Clauses 52.216-4 Economic Price Adjustment—Labor and Material. As prescribed in 16.203-4(c), when... specified in subparagraph (c)(4), upon approval by the chief of the contracting office. Economic Price...
48 CFR 52.216-4 - Economic Price Adjustment-Labor and Material.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 2 2014-10-01 2014-10-01 false Economic Price Adjustment... Clauses 52.216-4 Economic Price Adjustment—Labor and Material. As prescribed in 16.203-4(c), when... specified in subparagraph (c)(4), upon approval by the chief of the contracting office. Economic Price...
48 CFR 52.216-4 - Economic Price Adjustment-Labor and Material.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 2 2011-10-01 2011-10-01 false Economic Price Adjustment... Clauses 52.216-4 Economic Price Adjustment—Labor and Material. As prescribed in 16.203-4(c), when... specified in subparagraph (c)(4), upon approval by the chief of the contracting office. Economic Price...
48 CFR 52.216-4 - Economic Price Adjustment-Labor and Material.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 2 2012-10-01 2012-10-01 false Economic Price Adjustment... Clauses 52.216-4 Economic Price Adjustment—Labor and Material. As prescribed in 16.203-4(c), when... specified in subparagraph (c)(4), upon approval by the chief of the contracting office. Economic Price...
48 CFR 52.216-4 - Economic Price Adjustment-Labor and Material.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 2 2013-10-01 2013-10-01 false Economic Price Adjustment... Clauses 52.216-4 Economic Price Adjustment—Labor and Material. As prescribed in 16.203-4(c), when... specified in subparagraph (c)(4), upon approval by the chief of the contracting office. Economic Price...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-30
... and Clauses (DFARS Case 2011-D048) AGENCY: Defense Acquisition Regulations System, Department of...-- Representation. 252.216-7003, Economic Price 252.216-7008, Economic Price Adjustment--Wage Rates or Material Adjustment--Wage Rates or Prices Controlled by a Foreign Material Prices Controlled by Government. a Foreign...
A cohesive granular material with tunable elasticity
Hemmerle, Arnaud; Schröter, Matthias; Goehring, Lucas
2016-01-01
By mixing glass beads with a curable polymer we create a well-defined cohesive granular medium, held together by solidified, and hence elastic, capillary bridges. This material has a geometry similar to a wet packing of beads, but with an additional control over the elasticity of the bonds holding the particles together. We show that its mechanical response can be varied over several orders of magnitude by adjusting the size and stiffness of the bridges, and the size of the particles. We also investigate its mechanism of failure under unconfined uniaxial compression in combination with in situ x-ray microtomography. We show that a broad linear-elastic regime ends at a limiting strain of about 8%, whatever the stiffness of the agglomerate, which corresponds to the beginning of shear failure. The possibility to finely tune the stiffness, size and shape of this simple material makes it an ideal model system for investigations on, for example, fracturing of porous rocks, seismology, or root growth in cohesive porous media. PMID:27774988
High-sensitivity strain visualization using electroluminescence technologies
NASA Astrophysics Data System (ADS)
Xu, Jian; Jo, Hongki
2016-04-01
Visualizing mechanical strain/stress changes is an emerging area in structural health monitoring. Several ways are available for strain change visualization through the color/brightness change of the materials subjected to the mechanical stresses, for example, using mechanoluminescence (ML) materials and mechanoresponsive polymers (MRP). However, these approaches were not effectively applicable for civil engineering system yet, due to insufficient sensitivity to low-level strain of typical civil structures and limitation in measuring both static and dynamic strain. In this study, design and validation for high-sensitivity strain visualization using electroluminescence technologies are presented. A high-sensitivity Wheatstone bridge, of which bridge balance is precisely controllable circuits, is used with a gain-adjustable amplifier. The monochrome electroluminescence (EL) technology is employed to convert both static and dynamic strain change into brightness/color change of the EL materials, through either brightness change mode (BCM) or color alternation mode (CAM). A prototype has been made and calibrated in lab, the linearity between strain and brightness change has been investigated.
A cohesive granular material with tunable elasticity.
Hemmerle, Arnaud; Schröter, Matthias; Goehring, Lucas
2016-10-24
By mixing glass beads with a curable polymer we create a well-defined cohesive granular medium, held together by solidified, and hence elastic, capillary bridges. This material has a geometry similar to a wet packing of beads, but with an additional control over the elasticity of the bonds holding the particles together. We show that its mechanical response can be varied over several orders of magnitude by adjusting the size and stiffness of the bridges, and the size of the particles. We also investigate its mechanism of failure under unconfined uniaxial compression in combination with in situ x-ray microtomography. We show that a broad linear-elastic regime ends at a limiting strain of about 8%, whatever the stiffness of the agglomerate, which corresponds to the beginning of shear failure. The possibility to finely tune the stiffness, size and shape of this simple material makes it an ideal model system for investigations on, for example, fracturing of porous rocks, seismology, or root growth in cohesive porous media.
NASA Technical Reports Server (NTRS)
Fleming, J. R.
1978-01-01
The limits of blade tolerance were defined. The standard blades are T-2 thickness tolerance. Good results were obtained by using a slurry fluid consisting of mineral oil and a lubricity additive. Adjustments of the formulation and fine tuning of the cutting process with the new fluid are necessary. Test results and consultation indicate that the blade breakage encountered with water based slurries is unavoidable. Two full capacity (974 wafer) runs were made on the large prototype saw. Both runs resulted in extremely low yield. However, the reasons for the low yield were lack of proper technique rather than problems with machine function. The test on the effect of amount of material etched off of an as-sawn wafer on solar cell efficiency were completed. The results agree with previous work at JPL in that the minimum material removed per side that gives maximum efficiency is on the order of 10 microns.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-13
... collection OMB Control Number 1625-0046 entitled ``Financial Responsibility for Water Pollution (Vessels... Consumer Price Index Adjustments of Oil Pollution Act of 1990 Limits of Liability--Vessels and Deepwater..., the Coast Guard amended the Oil Pollution Act of 1990 limits of liability for vessels and deepwater...
Optical characterization of tissue mimicking phantoms by a vertical double integrating sphere system
NASA Astrophysics Data System (ADS)
Han, Yilin; Jia, Qiumin; Shen, Shuwei; Liu, Guangli; Guo, Yuwei; Zhou, Ximing; Chu, Jiaru; Zhao, Gang; Dong, Erbao; Allen, David W.; Lemaillet, Paul; Xu, Ronald
2016-03-01
Accurate characterization of absorption and scattering properties for biologic tissue and tissue-simulating materials enables 3D printing of traceable tissue-simulating phantoms for medical spectral device calibration and standardized medical optical imaging. Conventional double integrating sphere systems have several limitations and are suboptimal for optical characterization of liquid and soft materials used in 3D printing. We propose a vertical double integrating sphere system and the associated reconstruction algorithms for optical characterization of phantom materials that simulate different human tissue components. The system characterizes absorption and scattering properties of liquid and solid phantom materials in an operating wavelength range from 400 nm to 1100 nm. Absorption and scattering properties of the phantoms are adjusted by adding titanium dioxide powder and India ink, respectively. Different material compositions are added in the phantoms and characterized by the vertical double integrating sphere system in order to simulate the human tissue properties. Our test results suggest that the vertical integrating sphere system is able to characterize optical properties of tissue-simulating phantoms without precipitation effect of the liquid samples or wrinkling effect of the soft phantoms during the optical measurement.
Huang, L; Fantke, P; Ernstoff, A; Jolliet, O
2017-11-01
Indoor releases of organic chemicals encapsulated in solid materials are major contributors to human exposures and are directly related to the internal diffusion coefficient in solid materials. Existing correlations to estimate the diffusion coefficient are only valid for a limited number of chemical-material combinations. This paper develops and evaluates a quantitative property-property relationship (QPPR) to predict diffusion coefficients for a wide range of organic chemicals and materials. We first compiled a training dataset of 1103 measured diffusion coefficients for 158 chemicals in 32 consolidated material types. Following a detailed analysis of the temperature influence, we developed a multiple linear regression model to predict diffusion coefficients as a function of chemical molecular weight (MW), temperature, and material type (adjusted R 2 of .93). The internal validations showed the model to be robust, stable and not a result of chance correlation. The external validation against two separate prediction datasets demonstrated the model has good predicting ability within its applicability domain (Rext2>.8), namely MW between 30 and 1178 g/mol and temperature between 4 and 180°C. By covering a much wider range of organic chemicals and materials, this QPPR facilitates high-throughput estimates of human exposures for chemicals encapsulated in solid materials. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Zhao, Shanyu; Malfait, Wim J; Demilecamps, Arnaud; Zhang, Yucheng; Brunner, Samuel; Huber, Lukas; Tingaut, Philippe; Rigacci, Arnaud; Budtova, Tatiana; Koebel, Matthias M
2015-11-23
Silica aerogels are excellent thermal insulators, but their brittle nature has prevented widespread application. To overcome these mechanical limitations, silica-biopolymer hybrids are a promising alternative. A one-pot process to monolithic, superinsulating pectin-silica hybrid aerogels is presented. Their structural and physical properties can be tuned by adjusting the gelation pH and pectin concentration. Hybrid aerogels made at pH 1.5 exhibit minimal dust release and vastly improved mechanical properties while remaining excellent thermal insulators. The change in the mechanical properties is directly linked to the observed "neck-free" nanoscale network structure with thicker struts. Such a design is superior to "neck-limited", classical inorganic aerogels. This new class of materials opens up new perspectives for novel silica-biopolymer nanocomposite aerogels. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Advanced stitching head for making stitches in a textile article having variable thickness
NASA Technical Reports Server (NTRS)
Thrash, Patrick J. (Inventor); Miller, Jeffrey L. (Inventor); Codos, Richard (Inventor)
1999-01-01
A stitching head for a computer numerically controlled stitching machine includes a thread tensioning mechanism for automatically adjusting thread tension according to the thickness of the material being stitched. The stitching head also includes a mechanism for automatically adjusting thread path geometry according to the thickness of the material being stitched.
Surface passivation for CdTe devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reese, Matthew O.; Perkins, Craig L.; Burst, James M.
2017-08-01
In one embodiment, a method for surface passivation for CdTe devices is provided. The method includes adjusting a stoichiometry of a surface of a CdTe material layer such that the surface becomes at least one of stoichiometric or Cd-rich; and reconstructing a crystalline lattice at the surface of the CdTe material layer by annealing the adjusted surface.
Dynamic probability control limits for risk-adjusted CUSUM charts based on multiresponses.
Zhang, Xiang; Loda, Justin B; Woodall, William H
2017-07-20
For a patient who has survived a surgery, there could be several levels of recovery. Thus, it is reasonable to consider more than two outcomes when monitoring surgical outcome quality. The risk-adjusted cumulative sum (CUSUM) chart based on multiresponses has been developed for monitoring a surgical process with three or more outcomes. However, there is a significant effect of varying risk distributions on the in-control performance of the chart when constant control limits are applied. To overcome this disadvantage, we apply the dynamic probability control limits to the risk-adjusted CUSUM charts for multiresponses. The simulation results demonstrate that the in-control performance of the charts with dynamic probability control limits can be controlled for different patient populations because these limits are determined for each specific sequence of patients. Thus, the use of dynamic probability control limits for risk-adjusted CUSUM charts based on multiresponses allows each chart to be designed for the corresponding patient sequence of a surgeon or a hospital and therefore does not require estimating or monitoring the patients' risk distribution. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Dynamic Feed Control For Injection Molding
Kazmer, David O.
1996-09-17
The invention provides methods and apparatus in which mold material flows through a gate into a mold cavity that defines the shape of a desired part. An adjustable valve is provided that is operable to change dynamically the effective size of the gate to control the flow of mold material through the gate. The valve is adjustable while the mold material is flowing through the gate into the mold cavity. A sensor is provided for sensing a process condition while the part is being molded. During molding, the valve is adjusted based at least in part on information from the sensor. In the preferred embodiment, the adjustable valve is controlled by a digital computer, which includes circuitry for acquiring data from the sensor, processing circuitry for computing a desired position of the valve based on the data from the sensor and a control data file containing target process conditions, and control circuitry for generating signals to control a valve driver to adjust the position of the valve. More complex embodiments include a plurality of gates, sensors, and controllable valves. Each valve is individually controllable so that process conditions corresponding to each gate can be adjusted independently. This allows for great flexibility in the control of injection molding to produce complex, high-quality parts.
Reducing Acute Kidney Injury Due to Contrast Material: How Nurses Can Improve Patient Safety.
Lambert, Peggy; Chaisson, Kristine; Horton, Susan; Petrin, Carmen; Marshall, Emily; Bowden, Sue; Scott, Lynn; Conley, Sheila; Stender, Janette; Kent, Gertrude; Hopkins, Ellen; Smith, Brian; Nicholson, Anita; Roy, Nancy; Homsted, Brenda; Downs, Cindy; Ross, Cathy S; Brown, Jeremiah
2017-02-01
Acute kidney injury due to contrast material occurs in 3% to 15% of the 2 million cardiac catheterizations done in the United States each year. To reduce acute kidney injury due to contrast material after cardiovascular interventional procedures. Nurse leaders in the Northern New England Cardiovascular Disease Study Group, a 10-center quality improvement consortium in Maine, New Hampshire, and Vermont, formed a nursing task force to reduce acute kidney injury due to contrast material after cardiovascular interventional procedures. Data were prospectively collected January 1, 2007, through June 30, 2012, on consecutive nonemergent patients (n = 20 147) undergoing percutaneous coronary interventions. Compared with baseline rates, adjusted rates of acute kidney injury among the 10 centers were significantly reduced by 21% and by 28% in patients with baseline estimated glomerular filtration rate less than 60 mL/min per 1.73 m 2 . Key qualitative system factors associated with improvement included use of multidisciplinary teams, standardized fluid orders, use of an intravenous fluid bolus, patient education about oral hydration, and limiting the volume of contrast material. Standardization of evidence-based best practices in nursing care may reduce the incidence of acute kidney injury due to contrast material. ©2017 American Association of Critical-Care Nurses.
A health literate approach to the prevention of childhood overweight and obesity
White, Richard O.; Thompson, Jessica R.; Rothman, Russell L.; Scott, Amanda M. McDougald; Heerman, William J.; Sommer, Evan C.; Barkin, Shari L.
2013-01-01
Objective To describe a systematic assessment of patient educational materials for the Growing Right Onto Wellness (GROW) trial, a childhood obesity prevention study targeting a low health literate population. Methods Process included: (1) expert review of educational content, (2) assessment of the quality of materials including use of the Suitability Assessment of Materials (SAM) tool, and (3) material review and revision with target population. Results 12 core modules were developed and assessed in an iterative process. Average readability was at the 6th grade reading level (SMOG Index 5.63 ± 0.76, and Fry graph 6.0 ± 0.85). SAM evaluation resulted in adjustments to literacy demand, layout & typography, and learning stimulation & motivation. Cognitive interviews with target population revealed additional changes incorporated to enhance participant's perception of acceptability and feasibility for behavior change. Conclusion The GROW modules are a collection of evidence-based materials appropriate for parents with low health literacy and their preschool aged children, that target the prevention of childhood overweight/obesity. Practice implications Most trials addressing the treatment or prevention of childhood obesity use written materials. Due to the ubiquitous prevalence of limited health literacy, our described methods may assist researchers in ensuring their content is both understood and actionable. PMID:24001660
A health literate approach to the prevention of childhood overweight and obesity.
White, Richard O; Thompson, Jessica R; Rothman, Russell L; McDougald Scott, Amanda M; Heerman, William J; Sommer, Evan C; Barkin, Shari L
2013-12-01
To describe a systematic assessment of patient educational materials for the Growing Right Onto Wellness (GROW) trial, a childhood obesity prevention study targeting a low health literate population. Process included: (1) expert review of educational content, (2) assessment of the quality of materials including use of the Suitability Assessment of Materials (SAM) tool, and (3) material review and revision with target population. 12 core modules were developed and assessed in an iterative process. Average readability was at the 6th grade reading level (SMOG Index 5.63 ± 0.76, and Fry graph 6.0 ± 0.85). SAM evaluation resulted in adjustments to literacy demand, layout & typography, and learning stimulation & motivation. Cognitive interviews with target population revealed additional changes incorporated to enhance participant's perception of acceptability and feasibility for behavior change. The GROW modules are a collection of evidence-based materials appropriate for parents with low health literacy and their preschool aged children, that target the prevention of childhood overweight/obesity. Most trials addressing the treatment or prevention of childhood obesity use written materials. Due to the ubiquitous prevalence of limited health literacy, our described methods may assist researchers in ensuring their content is both understood and actionable. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
A Survey of Bioinspired Jumping Robot: Takeoff, Air Posture Adjustment, and Landing Buffer
2017-01-01
A bioinspired jumping robot has a strong ability to overcome obstacles. It can be applied to the occasion with complex and changeable environment, such as detection of planet surface, postdisaster relief, and military reconnaissance. So the bioinspired jumping robot has broad application prospect. The jumping process of the robot can be divided into three stages: takeoff, air posture adjustment, and landing buffer. The motivation of this review is to investigate the research results of the most published bioinspired jumping robots for these three stages. Then, the movement performance of the bioinspired jumping robots is analyzed and compared quantitatively. Then, the limitation of the research on bioinspired jumping robots is discussed, such as the research on the mechanism of biological motion is not thorough enough, the research method about structural design, material applications, and control are still traditional, and energy utilization is low, which make the robots far from practical applications. Finally, the development trend is summarized. This review provides a reference for further research of bioinspired jumping robots. PMID:29311756
Influence of hydrogen on formability and bendability of DP1180 steel for car body application
NASA Astrophysics Data System (ADS)
Gao, Q.; Han, F.; Wortberg, D.; Bleck, W.; Liewald, M.
2016-11-01
In order to reach future light weight targets, it is increasing necessary to use advanced high strength steels with tensile strength 980 MPa or higher in automotive body-inwhite structures. Due to the sensitivity to hydrogen embrittlement and the limited understanding of various aspects of hydrogen embrittlement on processing and function, the wide application of these steels is still limited. In the current work, the influence of hydrogen on the multiaxial forming behavior was investigated by determining the forming limit curve and bending limit curve of DP1180 steel. Hydrogen concentration in the material was modified by cathodic charging. Then Nakajima tests on hydrogen uncharged and pre-charged samples were carried out in order to adjust and study different strain states resulting in the forming limit curve. In the study of bending limit curve, the steel sheets were pre-strained by Marciniak test. Bending load on the uncharged and pre-charged samples was introduced by VDA238-100 bending tests. The experimental results indicated that the presence of hydrogen affected the formability and bendability of DP1180 steel. A clear difference in the influence of hydrogen at different strain states was observed. When formed in a biaxial strain state via the Nakajima test, the material showed the highest degradation in formability. Moreover, the samples with biaxial pre-loading showed more degradation in bendability comparing to those pre-strained in plane strain and uni-axial paths. Fractography by scanning electron microscope gave evidence of hydrogen-induced cleavage fracture on pre-charged Nakajima samples. Thus this investigation improves the understanding of influences of hydrogen on forming processes and provides important evidence for further studies on HE susceptibility of AHSS for the application on car body constructions.
Behaviour of a series of reservoirs separated by drowned gates
NASA Astrophysics Data System (ADS)
Kolechkina, Alla; van Nooijen, Ronald
2017-04-01
Modern control systems tend to be based on computers and therefore to operate by sending commands to structures at given intervals (discrete time control system). Moreover, for almost all water management control systems there are practical lower limits on the time interval between structure adjustments and even between measurements. The water resource systems that are being controlled are physical systems whose state changes continuously. If we combine a continuously changing system and a discrete time controller we get a hybrid system. We use material from recent control theory literature to examine the behaviour of a series of reservoirs separated by drowned gates where the gates are under computer control.
24 CFR 92.252 - Qualification as affordable housing: Rental housing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... include average occupancy per unit and adjusted income assumptions. (b) Additional Rent limitations. In... provides the HOME rent limits which include average occupancy per unit and adjusted income assumptions... occupied only by households that are eligible as low-income families and must meet the following...
Promotive Factors and Psychosocial Adjustment among Urban Youth
ERIC Educational Resources Information Center
O'Neal, LaToya J.; Cotten, Shelia R.
2016-01-01
Background: Urban youth are often exposed to compounded risk factors which make them more vulnerable to negative outcomes. Research examining promotive factors which may reduce vulnerabilities to poor psychosocial adjustment among this population is limited. Objective: The current study addresses this limitation by examining the impact of…
Polymeric blends for sensor and actuation dual functionality
NASA Technical Reports Server (NTRS)
St. Clair, Terry L. (Inventor); Harrison, Joycelyn S. (Inventor); Su, Ji (Inventor); Ounaies, Zoubeida (Inventor)
2004-01-01
The invention described herein supplies a new class of electroactive polymeric blend materials which offer both sensing and actuation dual functionality. The blend comprises two components, one component having a sensing capability and the other component having an actuating capability. These components should be co-processable and coexisting in a phase separated blend system. Specifically, the materials are blends of a sensing component selected from the group consisting of ferroelectric, piezoelectric, pyroelectric and photoelectric polymers and an actuating component that responds to an electric field in terms of dimensional change. Said actuating component includes, but is not limited to, electrostrictive graft elastomers, dielectric electroactive elastomers, liquid crystal electroactive elastomers and field responsive polymeric gels. The sensor functionality and actuation functionality are designed by tailoring the relative fraction of the two components. The temperature dependence of the piezoelectric response and the mechanical toughness of the dual functional blends are also tailored by the composition adjustment.
The Mars Simulation Laboratory, University of Aarhus
NASA Astrophysics Data System (ADS)
Merrison, J. P.; Field, D.; Finster, K.; Lomstein, B. Aa.; Nørnberg, P.; Ramsing, N. B.; Uggerhøj, E.
2001-08-01
Present day Mars presents an extremely hostile environment to organic material. The average temperature is low (-50C), the atmospheric pressure is also low (7mbar) and there is little water over most of the planet. Chemically the surface is extremely oxidising and no signs of organic material have been detected. There is also a strong component of ultra violet radiation in the Martian sun light, lethal to most organisms. At Aarhus University we have constructed a Mars simulation environment which reproduces the physical, chemical and mineralogical conditions on Mars. It is hoped to set limits on where organic matter (or even life) might exist on Mars, for example at some depth under the surface, beneath the polar ice or within rocks. It is also possible to adjust the conditions in the simulation to investigate the most extreme environments in which organisms can be preserved or still function.
Xie, Yun-Fei; Li, Yan; Yu, Hui; Qian, He; Yao, Wei-Rong
2014-03-01
In the present study, we developed a novel SERS substrate with the porous monolith material combined with classic gold nanoparticles, and erythrosine as the research object, by adjusting the different experimental conditions for optimal SERS enhancements, including system pH and mixing time, and ultimately selected the optimum pH value 5.06 and mixing time 25 min. Compared with the traditional gold plastic substrate enhancement effect, the experimental conditions were applied to the monolith substrate SERS detection of dye erythrosine, different concentrations of samples were used for erythrosine SERS detection, and the detection limit reached 0.1 g x mL(-1). The method uses the payload of gold nanoparticles in mesoporous materials to effectively enhance the SERS signal. And this method has the advantages of simpleness and good stability, which provides a favorable theoretical basis for the rapid prohibited colorings screening.
7 CFR 1400.501 - Determination of average adjusted gross income.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 10 2011-01-01 2011-01-01 false Determination of average adjusted gross income. 1400... PAYMENT ELIGIBILITY FOR 2009 AND SUBSEQUENT CROP, PROGRAM, OR FISCAL YEARS Average Adjusted Gross Income Limitation § 1400.501 Determination of average adjusted gross income. (a) Except as otherwise provided in...
78 FR 41285 - Airworthiness Directives; Pilatus Aircraft Ltd. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-10
... manual). The limitations were revised to include an emergency fuel control system adjustment test. We are... a 300 Flight Hour (FH) hour inspection on the Emergency Fuel Control System (FCS). For the reason...., maintenance manual). The limitations were revised to include an emergency fuel control system adjustment test...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-05
... Certification Regarding Eligibility To Apply for Worker Adjustment Assistance In accordance with Section 223 of... Certification of Eligibility to Apply for Worker Adjustment Assistance on January 21, 2010, applicable to workers of Tata Technologies Incorporated, a subsidiary of TATA Technologies Limited, Novi, Michigan. The...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-23
... Certification Regarding Eligibility To Apply for Worker Adjustment Assistance In accordance with section 223 of... Certification of Eligibility to Apply for Worker Adjustment Assistance on January 21, 2010, applicable to workers of Tata Technologies Incorporated, a subsidiary of TATA Technologies Limited, Novi, Michigan. The...
33 CFR 138.240 - Procedure for calculating limit of liability adjustments for inflation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... calculating limit of liability adjustments for inflation. (a) Formula for calculating a cumulative percent... Current Period), using the following escalation formula: Percent change in the Annual CPI-U = [(Annual CPI.... This cumulative percent change value is rounded to one decimal place. (b) Significance threshold. Not...
39 CFR 3010.22 - Calculation of less than annual limitation.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Postal Service files its notice of rate adjustment and dividing the sum by 12 (Recent Average). The partial year limitation is then calculated by dividing the Recent Average by the Recent Average from the most recent previous notice of rate adjustment (Previous Recent Average) applicable to each affected...
39 CFR 3010.22 - Calculation of less than annual limitation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Postal Service files its notice of rate adjustment and dividing the sum by 12 (Recent Average). The partial year limitation is then calculated by dividing the Recent Average by the Recent Average from the most recent previous notice of rate adjustment (Previous Recent Average) applicable to each affected...
39 CFR 3010.22 - Calculation of less than annual limitation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Postal Service files its notice of rate adjustment and dividing the sum by 12 (Recent Average). The partial year limitation is then calculated by dividing the Recent Average by the Recent Average from the most recent previous notice of rate adjustment (Previous Recent Average) applicable to each affected...
Polarization control of isolated high-harmonic pulses
NASA Astrophysics Data System (ADS)
Huang, Pei-Chi; Hernández-García, Carlos; Huang, Jen-Ting; Huang, Po-Yao; Lu, Chih-Hsuan; Rego, Laura; Hickstein, Daniel D.; Ellis, Jennifer L.; Jaron-Becker, Agnieszka; Becker, Andreas; Yang, Shang-Da; Durfee, Charles G.; Plaja, Luis; Kapteyn, Henry C.; Murnane, Margaret M.; Kung, A. H.; Chen, Ming-Chang
2018-06-01
High-harmonic generation driven by femtosecond lasers makes it possible to capture the fastest dynamics in molecules and materials. However, thus far, the shortest isolated attosecond pulses have only been produced with linear polarization, which limits the range of physics that can be explored. Here, we demonstrate robust polarization control of isolated extreme-ultraviolet pulses by exploiting non-collinear high-harmonic generation driven by two counter-rotating few-cycle laser beams. The circularly polarized supercontinuum is produced at a central photon energy of 33 eV with a transform limit of 190 as and a predicted linear chirp of 330 as. By adjusting the ellipticity of the two counter-rotating driving pulses simultaneously, we control the polarization state of isolated extreme-ultraviolet pulses—from circular through elliptical to linear polarization—without sacrificing conversion efficiency. Access to the purely circularly polarized supercontinuum, combined with full helicity and ellipticity control, paves the way towards attosecond metrology of circular dichroism.
Liquid chromatographic separation of zalcitabine and its stereoisomers.
Scypinski, S; Ross, A J
1994-10-01
A liquid chromatographic method capable of separating and quantitating the stereoisomers of zalcitabine has been developed and validated. The separation was achieved with an Astec Cyclobond I--RSP column and a mobile phase of 0.25% triethylamine in water adjusted to a pH of 6.5 with glacial acetic acid. All enantiomers were found to exhibit a linear response in the range of 0.1-10% in the presence of 100% zalcitabine. Precision of analysis was found to be less than 1.5% at a level of 1% relative to zalcitabine. The limit of detection for two of the three enantiomeric impurities was determined to be 0.05% relative to zalcitabine. The detection limit for the third was found to be 0.1%. This method was successfully applied to the analysis of reference standards and several production scale batches. All of these materials were found to be stereochemically pure to a level of 99.8% or better.
Liu, Wei; Dai, Xing; Bai, Zhuanling; Wang, Yanlong; Yang, Zaixing; Zhang, Linjuan; Xu, Lin; Chen, Lanhua; Li, Yuxiang; Gui, Daxiang; Diwu, Juan; Wang, Jianqiang; Zhou, Ruhong; Chai, Zhifang; Wang, Shuao
2017-04-04
Uranium is not only a strategic resource for the nuclear industry but also a global contaminant with high toxicity. Although several strategies have been established for detecting uranyl ions in water, searching for new uranium sensor material with great sensitivity, selectivity, and stability remains a challenge. We introduce here a hydrolytically stable mesoporous terbium(III)-based MOF material compound 1, whose channels are as large as 27 Å × 23 Å and are equipped with abundant exposed Lewis basic sites, the luminescence intensity of which can be efficiently and selectively quenched by uranyl ions. The detection limit in deionized water reaches 0.9 μg/L, far below the maximum contamination standard of 30 μg/L in drinking water defined by the United States Environmental Protection Agency, making compound 1 currently the only MOF material that can achieve this goal. More importantly, this material exhibits great capability in detecting uranyl ions in natural water systems such as lake water and seawater with pH being adjusted to 4, where huge excesses of competing ions are present. The uranyl detection limits in Dushu Lake water and in seawater were calculated to be 14.0 and 3.5 μg/L, respectively. This great detection capability originates from the selective binding of uranyl ions onto the Lewis basic sites of the MOF material, as demonstrated by synchrotron radiation extended X-ray adsorption fine structure, X-ray adsorption near edge structure, and first principles calculations, further leading to an effective energy transfer between the uranyl ions and the MOF skeleton.
ERIC Educational Resources Information Center
Ullman, Ellen
2012-01-01
Community colleges have long taken pride in their ability to adjust to changing workforce needs. They adjust when local plumbers union requires a new certification. They also adjust when a biotechnology manufacturer seeks workers to staff its state-of-the-art research facility. But what happens when a new industry materializes almost overnight?…
NASA Astrophysics Data System (ADS)
Jamróz, Weronika
2016-06-01
The paper shows the way enrgy-based models aproximate mechanical properties of hiperelastic materials. Main goal of research was to create a method of finding a set of material constants that are included in a strain energy function that constitutes a heart of an energy-based model. The most optimal set of material constants determines the best adjustment of a theoretical stress-strain relation to the experimental one. This kind of adjustment enables better prediction of behaviour of a chosen material. In order to obtain more precised solution the approximation was made with use of data obtained in a modern experiment widely describen in [1]. To save computation time main algorithm is based on genetic algorithms.
Dynamic multiplexed analysis method using ion mobility spectrometer
Belov, Mikhail E [Richland, WA
2010-05-18
A method for multiplexed analysis using ion mobility spectrometer in which the effectiveness and efficiency of the multiplexed method is optimized by automatically adjusting rates of passage of analyte materials through an IMS drift tube during operation of the system. This automatic adjustment is performed by the IMS instrument itself after determining the appropriate levels of adjustment according to the method of the present invention. In one example, the adjustment of the rates of passage for these materials is determined by quantifying the total number of analyte molecules delivered to the ion trap in a preselected period of time, comparing this number to the charge capacity of the ion trap, selecting a gate opening sequence; and implementing the selected gate opening sequence to obtain a preselected rate of analytes within said IMS drift tube.
NASA Technical Reports Server (NTRS)
Gunasekara, Onalli; Wong, Uland Y.; Furlong, Michael P.; Dille, Michael
2017-01-01
Current technologies of exploring habitable areas of icy moons are limited to flybys of space probes. This research project addresses long-term navigation of icy moons by developing a MATLAB adjustable trajectory based on the volume of plume material observed. Plumes expose materials from the sub-surface without accessing the subsurface. Aerial vehicles capable of scouting vapor plumes and detecting maximum plume material volumes, which are considered potentially habitable in inhospitable environments, would enable future deep-space missions to search for extraterrestrial organisms on the surface of icy moons. Although this platform is still a prototype, it demonstrates the potential aerial vehicles can have in improving the capabilities of long-term space navigation and enabling technology for detecting life in extreme environments. Additionally, this work is developing the capabilities that could be utilized as a platform for space biology research. For example, aerial vehicles that are sent to map extreme environments of icy moons or the planet Mars, could also carry small payloads with automated cell-biology experiments, designed to probe the biological response of low-gravity and high-radiation planetary environments, serving as a pathfinder for future human missions.
In vivo degradation of polyurethane foam with 55 wt % polyethylene glycol.
Broekema, Ferdinand I; Van Leeuwen, M Barbara M; Van Minnen, Baucke; Bos, Rudolf R M
2015-11-01
Most topical hemostatic agents are based on animal-derived products like collagen and gelatin. They carry the potential risk of pathogen transmission while adjustments in the production process of these materials are limited. A synthetic hemostatic agent based on polyurethane (PU) and polyethylene glycol (PEG) was developed to overcome these disadvantages. The goal of this study was to compare the degradation process of this biomaterial to collagen and gelatin hemostatic agents. Samples of the test materials were implanted subcutaneously in both rats and rabbits. The animals were sacrificed at certain time intervals up to three years and the explanted samples were microscopically assessed. The histological examination showed a comparable pattern of degradation for the different test materials. Remnants of gelatin and collagen were seen up to 26 and 39 weeks, respectively. For PU, it took up to three years before micro-particles of the material were no longer detected. All biomaterials showed a good biocompatibility and no severe foreign body reactions occurred. The good biocompatibility and predictable pattern of resorption indicate that PU can be used as a topical hemostatic agent. However, a degradation time comparable to collagen and gelatin would be favorable. © 2015 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vaskuri, Anna, E-mail: anna.vaskuri@aalto.fi; Kärhä, Petri; Heikkilä, Anu
2015-10-15
Polystyrene and many other materials turn yellow when exposed to ultraviolet (UV) radiation. All photodegradation mechanisms including photoyellowing are functions of the exposure wavelength, which can be described with an action spectrum. In this work, a new high-resolution transmittance measurement setup based on lasers has been developed for measuring color changes, such as the photoyellowing of translucent materials aged with a spectrograph. The measurement setup includes 14 power-stabilized laser lines between 325 nm and 933 nm wavelengths, of which one at a time is directed on to the aged sample. The power transmitted through the sample is measured with amore » silicon detector utilizing an integrating sphere. The sample is mounted on a high-resolution XY translation stage. Measurement at various locations aged with different wavelengths of exposure radiation gives the transmittance data required for acquiring the action spectrum. The combination of a UV spectrograph and the new high-resolution transmittance measurement setup enables a novel method for studying the UV-induced ageing of translucent materials with a spectral resolution of 3–8 nm, limited by the adjustable spectral bandwidth range of the spectrograph. These achievements form a significant improvement over earlier methods.« less
Lorenz, David L.; Robertson, Dale M.; Hall, David W.; Saad, David A.
2009-01-01
Many actions have been taken to reduce nutrient and suspended-sediment concentrations and the amount of nutrients and sediment transported in streams as a result of the Clean Water Act and subsequent regulations. This report assesses how nutrient and suspended-sediment concentrations and loads in selected streams have changed during recent years to determine if these actions have been successful. Flow-adjusted and overall trends in concentrations and trends in loads from 1993 to 2004 were computed for total nitrogen, dissolved ammonia, total organic nitrogen plus ammonia, dissolved nitrite plus nitrate, total phosphorus, dissolved phosphorus, total suspended material (total suspended solids or suspended sediment), and total suspended sediment for 49 sites in the Upper Mississippi, Ohio, Red, and Great Lakes Basins. Changes in total nitrogen, total phosphorus, and total suspended-material loads were examined from 1975 to 2003 at six sites to provide a longer term context for the data examined from 1993 to 2004. Flow-adjusted trends in total nitrogen concentrations at 19 of 24 sites showed tendency toward increasing concentrations, and overall trends in total nitrogen concentrations at 16 of the 24 sites showed a general tendency toward increasing concentrations. The trends in these flow-adjusted total nitrogen concentrations are related to the changes in fertilizer nitrogen applications. Flow-adjusted trends in dissolved ammonia concentrations from 1993 to 2004 showed a widespread tendency toward decreasing concentrations. The widespread, downward trends in dissolved ammonia concentrations indicate that some of the ammonia reduction goals of the Clean Water Act are being met. Flow-adjusted and overall trends in total organic plus ammonia nitrogen concentrations from 1993 to 2004 did not show a distinct spatial pattern. Flow-adjusted and overall trends in dissolved nitrite plus nitrate concentrations from 1993 to 2004 also did not show a distinct spatial pattern. Flow-adjusted trends in total phosphorus concentrations were upward at 24 of 40 sites. Overall trends in total phosphorus concentrations were mixed and showed no spatial pattern. Flow-adjusted and overall trends in dissolved phosphorus concentrations were consistently downward at all of the sites in the eastern part of the basins studied. The reduction in phosphorus fertilizer use and manure production east of the Mississippi River could explain most of the observed trends in dissolved phosphorus. Flow-adjusted trends in total suspended-material concentrations showed distinct spatial patterns of increasing tendencies throughout the western part of the basins studied and in Illinois and decreasing concentrations throughout most of Wisconsin, Iowa, and in the eastern part of the basins studied. Flow-adjusted trends in total phosphorus were strongly related to the flow-adjusted trends in suspended materials. The trends in the flow-adjusted suspended-sediment concentrations from 1993 to 2004 resembled those for suspended materials. The long-term, nonmonotonic trends in total nitrogen, total phosphorus, and suspended-material loads for 1975 to 2003 were described by local regression, LOESS, smoothing for six sites. The statistical significance of those trends cannot be determined; however, the long-term changes found for annual streamflow and load data indicate that the monotonic trends from 1993 to 2004 should not be extrapolated backward in time.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-17
... alternatives for each of three principal management measures: (1) The primary possession limit affecting the... measures in Framework Adjustment 1 to the Northeast Skate Complex Fishery Management Plan (Skate FMP). Framework Adjustment 1 was developed by the New England Fishery Management Council (Council) to adjust the...
Creation of economical and robust large area MCPs by ALD method for photodetectors
NASA Astrophysics Data System (ADS)
Mane, Anil U.; Elam, Jeffrey W.; Wagner, Robert G.; Siegmund, Oswald H. W.; Minot, Michael J.
2016-09-01
We report a cost-effective and production achievable path to fabricate robust large-area microchannel plates (MCPs), which offers the new prospect for larger area MCP-based detector technologies. We used atomic Layer Deposition (ALD), a thin film growth technique, to independently adjust the desired electrical resistance and secondary electron emission (SEE) properties of low cost borosilicate glass micro-capillary arrays (MCAs). These capabilities allow a separation of the substrate material properties from the signal amplification properties. This methodology enables the functionalization of microporous, highly insulating MCA substrates to produce sturdy, large format MCPs with unique properties such as high gain (<107/MCP pair), low background noise, 10ps time resolution, sub-micron spatial resolution and excellent stability after only a short (2-3days) scrubbing time. The ALD self-limiting growth mechanism allows atomic level control over the thickness and composition of resistive and secondary electron emission (SEE) layers that can be deposited conformally on high aspect ratio ( 100) capillary glass arrays. We have developed several robust and consistent production doable ALD processes for the resistive coatings and SEE layers to give us precise control over the MCP parameters. Further, the adjustment of MCPs resistance by tailoring the ALD material composition permits the use of these MCPs at high or low temperature detector applications. Here we discuss ALD method for MCP functionalization and a variety of MCP testing results.
Kohl, Kevin D; Brun, Antonio; Magallanes, Melisa; Brinkerhoff, Joshua; Laspiur, Alejandro; Acosta, Juan Carlos; Bordenstein, Seth R; Caviedes-Vidal, Enrique
2016-06-15
While herbivory is a common feeding strategy in a number of vertebrate classes, less than 4% of squamate reptiles feed primarily on plant material. It has been hypothesized that physiological or microbial limitations may constrain the evolution of herbivory in lizards. Herbivorous lizards exhibit adaptations in digestive morphology and function that allow them to better assimilate plant material. However, it is unknown whether these traits are fixed or perhaps phenotypically flexible as a result of diet. Here, we maintained a naturally omnivorous lizard, Liolaemus ruibali, on a mixed diet of 50% insects and 50% plant material, or a plant-rich diet of 90% plant material. We compared parameters of digestive performance, gut morphology and function, and gut microbial community structure between the two groups. We found that lizards fed the plant-rich diet maintained nitrogen balance and exhibited low minimum nitrogen requirements. Additionally, lizards fed the plant-rich diet exhibited significantly longer small intestines and larger hindguts, demonstrating that gut morphology is phenotypically flexible. Lizards fed the plant-rich diet harbored small intestinal communities that were more diverse and enriched in Melainabacteria and Oscillospira compared with mixed diet-fed lizards. Additionally, the relative abundance of sulfate-reducing bacteria in the small intestine significantly correlated with whole-animal fiber digestibility. Thus, we suggest that physiological and microbial limitations do not sensu stricto constrain the evolution of herbivory in lizards. Rather, ecological context and fitness consequences may be more important in driving the evolution of this feeding strategy. © 2016. Published by The Company of Biologists Ltd.
ERIC Educational Resources Information Center
Barker, Edward D.; Oliver, Bonamy R.; Maughan, Barbara
2010-01-01
Background: It is increasingly recognized that youth who follow early onset persistent (EOP), childhood limited (CL) and adolescent onset (AO) trajectories of conduct problems show somewhat varying patterns of risk (in childhood) and adjustment problems (in adolescence and adulthood). Little, however, is known about how other adjustment problems…
38 CFR 3.28 - Automatic adjustment of section 306 and old-law pension income limitations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 38 Pensions, Bonuses, and Veterans' Relief 1 2013-07-01 2013-07-01 false Automatic adjustment of section 306 and old-law pension income limitations. 3.28 Section 3.28 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS ADJUDICATION Pension, Compensation, and Dependency and Indemnity...
38 CFR 3.28 - Automatic adjustment of section 306 and old-law pension income limitations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Automatic adjustment of section 306 and old-law pension income limitations. 3.28 Section 3.28 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS ADJUDICATION Pension, Compensation, and Dependency and Indemnity...
38 CFR 3.28 - Automatic adjustment of section 306 and old-law pension income limitations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 38 Pensions, Bonuses, and Veterans' Relief 1 2012-07-01 2012-07-01 false Automatic adjustment of section 306 and old-law pension income limitations. 3.28 Section 3.28 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS ADJUDICATION Pension, Compensation, and Dependency and Indemnity...
38 CFR 3.28 - Automatic adjustment of section 306 and old-law pension income limitations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 38 Pensions, Bonuses, and Veterans' Relief 1 2011-07-01 2011-07-01 false Automatic adjustment of section 306 and old-law pension income limitations. 3.28 Section 3.28 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS ADJUDICATION Pension, Compensation, and Dependency and Indemnity...
38 CFR 3.28 - Automatic adjustment of section 306 and old-law pension income limitations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 38 Pensions, Bonuses, and Veterans' Relief 1 2014-07-01 2014-07-01 false Automatic adjustment of section 306 and old-law pension income limitations. 3.28 Section 3.28 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS ADJUDICATION Pension, Compensation, and Dependency and Indemnity...
42 CFR 419.70 - Transitional adjustments to limit decline in payments.
Code of Federal Regulations, 2010 CFR
2010-10-01
... mental health center (CMHC) in a year, an amount equal to the product of the reasonable cost of the... 42 Public Health 3 2010-10-01 2010-10-01 false Transitional adjustments to limit decline in payments. 419.70 Section 419.70 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF...
Dynamic probability control limits for risk-adjusted Bernoulli CUSUM charts.
Zhang, Xiang; Woodall, William H
2015-11-10
The risk-adjusted Bernoulli cumulative sum (CUSUM) chart developed by Steiner et al. (2000) is an increasingly popular tool for monitoring clinical and surgical performance. In practice, however, the use of a fixed control limit for the chart leads to a quite variable in-control average run length performance for patient populations with different risk score distributions. To overcome this problem, we determine simulation-based dynamic probability control limits (DPCLs) patient-by-patient for the risk-adjusted Bernoulli CUSUM charts. By maintaining the probability of a false alarm at a constant level conditional on no false alarm for previous observations, our risk-adjusted CUSUM charts with DPCLs have consistent in-control performance at the desired level with approximately geometrically distributed run lengths. Our simulation results demonstrate that our method does not rely on any information or assumptions about the patients' risk distributions. The use of DPCLs for risk-adjusted Bernoulli CUSUM charts allows each chart to be designed for the corresponding particular sequence of patients for a surgeon or hospital. Copyright © 2015 John Wiley & Sons, Ltd.
Plasma gun with coaxial powder feed and adjustable cathode
NASA Technical Reports Server (NTRS)
Zaplatynsky, Isidor (Inventor)
1991-01-01
An improved plasma gun coaxially injects particles of ceramic materials having high melting temperatures into the central portion of a plasma jet. This results in a more uniform and higher temperature and velocity distribution of the sprayed particles. The position of the cathode is adjustable to facilitate optimization of the performance of the gun wherein grains of the ceramic material are melted at lower power input levels.
How firms set prices for medical materials: a multi-country study.
Ide, Hiroo; Mollahaliloglu, Salih
2009-09-01
This study presents a comparison of medical material prices, discusses why differences exist, and examines methods for comparing prices. Market prices for drug-eluting stents (DES), non-drug-eluting stents (non-DES), and percutaneous transluminal coronary angioplasty (PTCA) catheters were collected from five countries: the United States, Japan, Korea, Turkey, and Thailand. To compare prices, three adjustment methods were used: currency exchange rates, purchasing power parity (PPP), and gross domestic product (GDP) per capita. The ratios of medical material prices compared with those in the United States were higher in Japan (from 1.4 for DES to 5.0 for PTCA catheters) and Korea (from 1.2 for DES to 4.0 for PTCA catheters), and lower in Turkey (from 0.8 for non-DES to 1.4 for DES) and Thailand (from 0.5 for non-DES to 1.3 for PTCA catheters). The PPP-adjusted ratios changed slightly for Japan, Korea, and Turkey. When the prices were adjusted by GDP per capita, the ratios were much higher. Comparing prices using currency exchange rates or PPP is applicable only between countries with stable economic relations; adjustment by GDP per capita reflects the actual burden. Further study is needed to fully elucidate the factors influencing the global medical material market.
Villevieille, Claire; Takeuchi, Yoji
2015-01-01
To understand inhomogeneous reactions perpendicular to the current collector in an electrode for batteries, a method combining operando synchrotron X‐ray diffraction and two‐layer electrodes with different porosities is developed. The two layers are built using two different active materials (LiNi0.80Co0.15Al0.05O2 and LiMn2O4), therefore, tracing each diffraction pattern reveals which active material is reacting during the electrochemical measurement in transmission mode. The results demonstrate that the active material close to the separator is obviously more active than that one close to the current collector in the case of low porosity electrodes. This inhomogeneity should be due to the rate‐limitation and especially to low average ionic conductivity of the electrolyte in the porous electrode because the current flows first mainly into the electrode regions close to the separator. The inhomogeneity is found to be mitigated by the adjustment of the electrode density and thus porosity. Hence, the novel operando method reveals a clear inhomogeneous reaction perpendicular to the current collector. PMID:27708998
NASA Astrophysics Data System (ADS)
Li, Jing; Zhang, Yining; Zhou, Wei; Nie, Hongjiao; Zhang, Huamin
2014-09-01
Li-O2 batteries have attracted considerable attention due to their high energy density. The critical challenges that limit the practical applications include effective utilization of electrode space for solid products deposition and acceptable cycling performance. In the present work, a nitrogen-doped micron-sized honeycomb-like carbon is developed for use as a cathode material for Li-O2 batteries. This novel material is obtained by using nano-CaCO3 particles as hard template and sucrose as the carbon source, followed by thermal annealing at 800 °C in ammonia. With one-step ammonia activation, surface nitrogenation and further pore structure optimization are realized simultaneously. The material exhibits enhanced activity for oxygen reduction reaction and oxygen transfer ability. Surprisingly, an improved cycling stability is also obtained. As a result, a superior discharge capacity up to 12,600 mAh g-1 is achieved, about 4 times that of commercial Ketjenblack carbon. The results provide a novel route to construct effective non-metal carbon-based cathodes for high performance of Li-O2 batteries.
A Microwave Thermostatic Reactor for Processing Liquid Materials Based on a Heat-Exchanger.
Zhou, Yongqiang; Zhang, Chun; Xie, Tian; Hong, Tao; Zhu, Huacheng; Yang, Yang; Liu, Changjun; Huang, Kama
2017-10-08
Microwaves have been widely used in the treatment of different materials. However, the existing adjustable power thermostatic reactors cannot be used to analyze materials characteristics under microwave effects. In this paper, a microwave thermostatic chemical reactor for processing liquid materials is proposed, by controlling the velocity of coolant based on PLC (programmable logic controller) in different liquid under different constant electric field intensity. A nonpolar coolant (Polydimethylsiloxane), which is completely microwave transparent, is employed to cool the liquid materials. Experiments are performed to measure the liquid temperature using optical fibers, the results show that the precision of temperature control is at the range of ±0.5 °C. Compared with the adjustable power thermostatic control system, the effect of electric field changes on material properties are avoided and it also can be used to detect the properties of liquid materials and special microwave effects.
A Microwave Thermostatic Reactor for Processing Liquid Materials Based on a Heat-Exchanger
Zhou, Yongqiang; Zhang, Chun; Xie, Tian; Hong, Tao; Yang, Yang; Liu, Changjun; Huang, Kama
2017-01-01
Microwaves have been widely used in the treatment of different materials. However, the existing adjustable power thermostatic reactors cannot be used to analyze materials characteristics under microwave effects. In this paper, a microwave thermostatic chemical reactor for processing liquid materials is proposed, by controlling the velocity of coolant based on PLC (programmable logic controller) in different liquid under different constant electric field intensity. A nonpolar coolant (Polydimethylsiloxane), which is completely microwave transparent, is employed to cool the liquid materials. Experiments are performed to measure the liquid temperature using optical fibers, the results show that the precision of temperature control is at the range of ±0.5 °C. Compared with the adjustable power thermostatic control system, the effect of electric field changes on material properties are avoided and it also can be used to detect the properties of liquid materials and special microwave effects. PMID:28991195
One-step method for the production of nanofluids
Kostic, Milivoje [Chicago, IL; Golubovic, Mihajlo [Chicago, IL; Hull, John R [Downers Grove, IL; Choi, Stephen U. S. [Napersville, IL
2010-05-18
A one step method and system for producing nanofluids by a particle-source evaporation and deposition of the evaporant into a base fluid. The base fluid such (i.e. ethylene glycol) is placed in a rotating cylindrical drum having an adjustable heater-boat-evaporator and heat exchanger-cooler apparatus. As the drum rotates, a thin liquid layer is formed on the inside surface of the drum. A heater-boat-evaporator having an evaporant material (particle-source) placed within its boat evaporator is adjustably positioned near a portion of the rotating thin liquid layer, the evaporant material being heated thereby evaporating a portion of the evaporant material, the evaporated material absorbed by the liquid film to form nanofluid.
Benke, Roland R.; Kearfott, Kimberlee J.; McGregor, Douglas S.
2003-03-04
A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The collimator may be a hollow cylinder positioned so that its central axis is perpendicular to the upper surface of the large area source when positioned thereon. The collimator allows the detector to angularly sample the emitted radiation over many ranges of polar angles. This is done by forming the collimator as a single adjustable collimator or a set of collimator pieces having various possible configurations when connected together. In any one configuration, the collimator allows the detector to detect only the radiation emitted from a selected range of polar angles measured from the detector axis. Adjustment of the collimator or the detector therein enables the detector to detect radiation emitted from a different range of polar angles. The system further includes a signal processor for processing the signals from the detector wherein signals obtained from different ranges of polar angles are processed together to obtain a reconstruction of the radiation-emitting material as a function of depth, assuming, but not limited to, a spatially-uniform depth distribution of the material within each layer. The detector system includes detectors having different properties (sensitivity, energy resolution) which are combined so that excellent spectral information may be obtained along with good determinations of the radiation field as a function of position.
Forecasting waste compositions: A case study on plastic waste of electronic display housings.
Peeters, Jef R; Vanegas, Paul; Kellens, Karel; Wang, Feng; Huisman, Jaco; Dewulf, Wim; Duflou, Joost R
2015-12-01
Because of the rapid succession of technological developments, the architecture and material composition of many products used in daily life have drastically changed over the last decades. As a result, well-adjusted recycling technologies need to be developed and installed to cope with these evolutions. This is essential to guarantee continued access to materials and to reduce the ecological impact of our material consumption. However, limited information is currently available on the material composition of arising waste streams and even less on how these waste streams will evolve. Therefore, this paper presents a methodology to forecast trends in the material composition of waste streams. To demonstrate the applicability and value of the proposed methodology, it is applied to forecast the evolution of plastic housing waste from flat panel display (FPD) TVs, FPD monitors, cathode ray tube (CRT) TVs and CRT monitors. The results of the presented forecasts indicate that a wide variety of plastic types and additives, such as flame retardants, are found in housings of similar products. The presented case study demonstrates that the proposed methodology allows the identification of trends in the evolution of the material composition of waste streams. In addition, it is demonstrated that the recycling sector will need to adapt its processes to deal with the increasing complexity of plastics of end-of-life electronic displays while respecting relevant directives. Copyright © 2015 Elsevier Ltd. All rights reserved.
Analysis of mortality in colorectal surgery in the Bi-National Colorectal Cancer Audit.
Teloken, Patrick Ely; Spilsbury, Katrina; Platell, Cameron
2016-06-01
In the last decade, there has been a significant increase in interest for public reporting of outcome data and performance comparison across institutions and surgeons. This study aims at comparing postoperative mortality after colorectal cancer surgery across units and individual consultants in Australia and New Zealand using funnel plots. The Bi-National Colorectal Cancer Audit database was used. Unadjusted and adjusted funnel plots of inpatient mortality were constructed. Risk adjustment was based upon multivariable logistic regression models using purposeful covariate selection. A total of 10 008 patients undergoing surgery for colorectal cancer from 56 surgical units and 90 consultants were identified. Overall inpatient mortality was 1.51%, corresponding to 1.1% for elective and 3.9% for urgent cases. Logistic regression identified age, American Society of Anesthesiologists score, urgent surgery and open surgery to be independently associated with inpatient mortality. Unadjusted and adjusted funnel plot analysis identified three (5.3%) units exceeding the inner limit and none exceeding the outer limit. Six (6.6%) consultants had inpatient mortality between the upper inner and outer limits and one (1.1%) between the inferior inner and outer limits. Upon adjustment, seven (7.7%) consultants had inpatient mortality between the inner and outer limit. Potential limitations of this study include: residual confounding being responsible for the association of open surgery and mortality; incomplete case-mix adjustment resulting in outlier identification; and bias towards inclusion of larger institutions. Mortality figures in Australia and New Zealand are comparable to recently reported international data. The vast majority of units and consultants are performing within the expected boundaries. © 2016 Royal Australasian College of Surgeons.
Production of high specific activity silicon-32
Phillips, Dennis R.; Brzezinski, Mark A.
1994-01-01
A process for preparation of silicon-32 is provide and includes contacting an irradiated potassium chloride target, including spallation products from a prior irradiation, with sufficient water, hydrochloric acid or potassium hydroxide to form a solution, filtering the solution, adjusting pH of the solution to from about 5.5 to about 7.5, admixing sufficient molybdate-reagent to the solution to adjust the pH of the solution to about 1.5 and to form a silicon-molybdate complex, contacting the solution including the silicon-molybdate complex with a dextran-based material, washing the dextran-based material to remove residual contaminants such as sodium-22, separating the silicon-molybdate complex from the dextran-based material as another solution, adding sufficient hydrochloric acid and hydrogen peroxide to the solution to prevent reformation of the silicon-molybdate complex and to yield an oxidization state of the molybdate adapted for subsequent separation by an anion exchange material, contacting the solution with an anion exchange material whereby the molybdate is retained by the anion exchange material and the silicon remains in solution, and optionally adding sufficient alkali metal hydroxide to adjust the pH of the solution to about 12 to 13. Additionally, a high specific activity silicon-32 product having a high purity is provided.
High specific activity silicon-32
Phillips, Dennis R.; Brzezinski, Mark A.
1996-01-01
A process for preparation of silicon-32 is provided and includes contacting an irradiated potassium chloride target, including spallation products from a prior irradiation, with sufficient water, hydrochloric acid or potassium hydroxide to form a solution, filtering the solution, adjusting pH of the solution to from about 5.5 to about 7.5, admixing sufficient molybdate-reagent to the solution to adjust the pH of the solution to about 1.5 and to form a silicon-molybdate complex, contacting the solution including the silicon-molybdate complex with a dextran-based material, washing the dextran-based material to remove residual contaminants such as sodium-22, separating the silicon-molybdate complex from the dextran-based material as another solution, adding sufficient hydrochloric acid and hydrogen peroxide to the solution to prevent reformation of the silicon-molybdate complex and to yield an oxidization state of the molybdate adapted for subsequent separation by an anion exchange material, contacting the solution with an anion exchange material whereby the molybdate is retained by the anion exchange material and the silicon remains in solution, and optionally adding sufficient alkali metal hydroxide to adjust the pH of the solution to about 12 to 13. Additionally, a high specific activity silicon-32 product having a high purity is provided.
High specific activity silicon-32
Phillips, D.R.; Brzezinski, M.A.
1996-06-11
A process for preparation of silicon-32 is provided and includes contacting an irradiated potassium chloride target, including spallation products from a prior irradiation, with sufficient water, hydrochloric acid or potassium hydroxide to form a solution, filtering the solution, adjusting pH of the solution from about 5.5 to about 7.5, admixing sufficient molybdate-reagent to the solution to adjust the pH of the solution to about 1.5 and to form a silicon-molybdate complex, contacting the solution including the silicon-molybdate complex with a dextran-based material, washing the dextran-based material to remove residual contaminants such as sodium-22, separating the silicon-molybdate complex from the dextran-based material as another solution, adding sufficient hydrochloric acid and hydrogen peroxide to the solution to prevent reformation of the silicon-molybdate complex and to yield an oxidation state of the molybdate adapted for subsequent separation by an anion exchange material, contacting the solution with an anion exchange material whereby the molybdate is retained by the anion exchange material and the silicon remains in solution, and optionally adding sufficient alkali metal hydroxide to adjust the pH of the solution to about 12 to 13. Additionally, a high specific activity silicon-32 product having a high purity is provided.
Nanoparticle Superlattice Engineering with DNA
NASA Astrophysics Data System (ADS)
Macfarlane, Robert J.; Lee, Byeongdu; Jones, Matthew R.; Harris, Nadine; Schatz, George C.; Mirkin, Chad A.
2011-10-01
A current limitation in nanoparticle superlattice engineering is that the identities of the particles being assembled often determine the structures that can be synthesized. Therefore, specific crystallographic symmetries or lattice parameters can only be achieved using specific nanoparticles as building blocks (and vice versa). We present six design rules that can be used to deliberately prepare nine distinct colloidal crystal structures, with control over lattice parameters on the 25- to 150-nanometer length scale. These design rules outline a strategy to independently adjust each of the relevant crystallographic parameters, including particle size (5 to 60 nanometers), periodicity, and interparticle distance. As such, this work represents an advance in synthesizing tailorable macroscale architectures comprising nanoscale materials in a predictable fashion.
Kheifets, Aaron; Gallistel, C R
2012-05-29
Animals successfully navigate the world despite having only incomplete information about behaviorally important contingencies. It is an open question to what degree this behavior is driven by estimates of stochastic parameters (brain-constructed models of the experienced world) and to what degree it is directed by reinforcement-driven processes that optimize behavior in the limit without estimating stochastic parameters (model-free adaptation processes, such as associative learning). We find that mice adjust their behavior in response to a change in probability more quickly and abruptly than can be explained by differential reinforcement. Our results imply that mice represent probabilities and perform calculations over them to optimize their behavior, even when the optimization produces negligible material gain.
Kheifets, Aaron; Gallistel, C. R.
2012-01-01
Animals successfully navigate the world despite having only incomplete information about behaviorally important contingencies. It is an open question to what degree this behavior is driven by estimates of stochastic parameters (brain-constructed models of the experienced world) and to what degree it is directed by reinforcement-driven processes that optimize behavior in the limit without estimating stochastic parameters (model-free adaptation processes, such as associative learning). We find that mice adjust their behavior in response to a change in probability more quickly and abruptly than can be explained by differential reinforcement. Our results imply that mice represent probabilities and perform calculations over them to optimize their behavior, even when the optimization produces negligible material gain. PMID:22592792
Fidler, Richard L; Pelter, Michele M; Drew, Barbara J; Palacios, Jorge Arroyo; Bai, Yong; Stannard, Daphne; Aldrich, J Matt; Hu, Xiao
2017-01-01
Heart rate (HR) alarms are prevalent in ICU, and these parameters are configurable. Not much is known about nursing behavior associated with tailoring HR alarm parameters to individual patients to reduce clinical alarm fatigue. To understand the relationship between heart rate (HR) alarms and adjustments to reduce unnecessary heart rate alarms. Retrospective, quantitative analysis of an adjudicated database using analytical approaches to understand behaviors surrounding parameter HR alarm adjustments. Patients were sampled from five adult ICUs (77 beds) over one month at a quaternary care university medical center. A total of 337 of 461 ICU patients had HR alarms with 53.7% male, mean age 60.3 years, and 39% non-Caucasian. Default HR alarm parameters were 50 and 130 beats per minute (bpm). The occurrence of each alarm, vital signs, and physiologic waveforms was stored in a relational database (SQL server). There were 23,624 HR alarms for analysis, with 65.4% exceeding the upper heart rate limit. Only 51% of patients with HR alarms had parameters adjusted, with a median upper limit change of +5 bpm and -1 bpm lower limit. The median time to first HR parameter adjustment was 17.9 hours, without reduction in alarms occurrence (p = 0.57). HR alarms are prevalent in ICU, and half of HR alarm settings remain at default. There is a long delay between HR alarms and parameters changes, with insufficient changes to decrease HR alarms. Increasing frequency of HR alarms shortens the time to first adjustment. Best practice guidelines for HR alarm limits are needed to reduce alarm fatigue and improve monitoring precision.
Parabolic trough solar collector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eaton, J.H.
1985-01-15
A parabolic trough solar collector using reflective flexible materials is disclosed. A parabolic cylinder mirror is formed by stretching a flexible reflecting material between two parabolic end formers. The formers are held in place by a spreader bar. The resulting mirror is made to track the sun, focusing the sun's rays on a receiver tube. The ends of the reflective material are attached by glue or other suitable means to attachment straps. The flexible mirror is then attached to the formers. The attachment straps are mounted in brackets and tensioned by tightening associated nuts on the ends of the attachmentmore » straps. This serves both to stretch the flexible material orthogonal to the receiver tube and to hold the flexible material on the formers. The flexible mirror is stretched in the direction of the receiver tube by adjusting tensioning nuts. If materials with matching coefficients of expansion for temperature and humidity have been chosen, for example, aluminum foil for the flexible mirror and aluminum for the spreader bar, the mirror will stay in adjustment through temperature and humidity excursions. With dissimilar materials, e.g., aluminized mylar or other polymeric material and steel, spacers can be replaced with springs to maintain proper adjustment. The spreader bar cross section is chosen to be in the optic shadow of the receiver tube when tracking and not to intercept rays of the sun that would otherwise reach the receiver tube. This invention can also be used to make non-parabolic mirrors for other apparatus and applications.« less
Amaral, Marina; Rocha, Regina FV; Melo, Renata Marques; Pereira, Gabriel KR; Zhang, Yu; Valandro, Luiz Felipe; Bottino, Marco Antonio
2017-01-01
Objectives To determine the fatigue limits of three-unit monolithic zirconia FDPs before and after grinding of the gingival areas of connectors with diamond burs. Material and Methods FDPs were milled from pre-sintered blocks of zirconia simulating the absence of the first mandibular molar. Half of the specimens were subjected to grinding, simulating clinical adjustment, and all of them were subjected to glazing procedure. Additional specimens were manufactured for roughness analysis. FDPs were adhesively cemented onto glass-fiber reinforced epoxy resin abutments. Fatigue limits and standard deviations were obtained using a staircase fatigue method (n = 20, 100,000 loading cycles/5 Hz). The initial test load was 70% of the mean load-to-fracture (n = 3) and load increments were 5% of the initial test load for both the control and ground specimens. Data were compared by Student’s T-test (α ≤ 0.05). Results Both the control and ground groups exhibited similar values of load-to-fracture and fatigue limits. Neither the surface treatments nor ageing affected the surface roughness of the specimens. Conclusions The damage induced by grinding with fine-grit diamond bur in the gingival area of the connectors did not decrease the fatigue limit of the three-unit monolithic zirconia FDP. PMID:28494273
NASA Astrophysics Data System (ADS)
Rianti, R. A.; Priaminiarti, M.; Syahraini, S. I.
2017-08-01
Image enhancement brightness and contrast can be adjusted on lateral cephalometric digital radiographs to improve image quality and anatomic landmarks for measurement by Steiner analysis. To determine the limit value for adjustments of image enhancement brightness and contrast in lateral cephalometric digital radiography for Steiner analysis. Image enhancement brightness and contrast were adjusted on 100 lateral cephalometric radiography in 10-point increments (-30, -20, -10, 0, +10, +20, +30). Steiner analysis measurements were then performed by two observers. Reliabilities were tested by the Interclass Correlation Coefficient (ICC) and significance tested by ANOVA or the Kruskal Wallis test. No significant differences were detected in lateral cephalometric analysis measurements following adjustment of the image enhancement brightness and contrast. The limit value of adjustments of the image enhancement brightness and contrast associated with incremental 10-point changes (-30, -20, -10, 0, +10, +20, +30) does not affect the results of Steiner analysis.
Code of Federal Regulations, 2014 CFR
2014-07-01
... the Postal Service files its notice of rate adjustment and dividing the sum by 12 (Recent Average... values immediately preceding the Recent Average and dividing the sum by 12 (Base Average). Finally, the full year limitation is calculated by dividing the Recent Average by the Base Average and subtracting 1...
Code of Federal Regulations, 2014 CFR
2014-07-01
... dividing the sum by 12 (Recent Average). The partial year limitation is then calculated by dividing the Recent Average by the Recent Average from the most recent previous notice of rate adjustment (Previous Recent Average) applicable to each affected class of mail and subtracting 1 from the quotient. The result...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-21
...As mandated by provisions of the Federal Election Campaign Act of 1971, as amended (``FECA'' or ``the Act''), the Federal Election Commission (``FEC'' or ``the Commission'') is adjusting certain expenditure limitations and the lobbyist bundling disclosure threshold set forth in the Act, to index the amounts for inflation. Additional details appear in the supplemental information that follows.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-24
...As mandated by provisions of the Federal Election Campaign Act of 1971, as amended (``FECA'' or ``the Act''), the Federal Election Commission (``FEC'' or ``the Commission'') is adjusting certain expenditure limitations and the lobbyist bundling disclosure threshold set forth in the Act, to index the amounts for inflation. Additional details appear in the supplemental information that follows.
Jennings, Wesley G; Rocque, Michael; Fox, Bryanna Hahn; Piquero, Alex R; Farrington, David P
2016-05-01
Much research has examined Moffitt's developmental taxonomy, focusing almost exclusively on the distinction between life-course persistent and adolescence-limited offenders. Of interest, a handful of studies have identified a group of individuals whose early childhood years were marked by extensive antisocial behavior but who seemed to recover and desist (at least from severe offending) in adolescence and early adulthood. We use data from the Cambridge Study in Delinquent Development to examine the adult adjustment outcomes of different groups of offenders, including a recoveries group, in late middle adulthood, offering the most comprehensive investigation of this particular group to date. Findings indicate that abstainers comprise the largest group of males followed by adolescence-limited offenders, recoveries, and life-course persistent offenders. Furthermore, the results reveal that a host of adult adjustment problems measured at ages 32 and 48 in a number of life-course domains are differentially distributed across these four offender groups. In addition, the recoveries and life-course persistent offenders often show the greatest number of adult adjustment problems relative to the adolescence-limited offenders and abstainers.
48 CFR 16.203-2 - Application.
Code of Federal Regulations, 2011 CFR
2011-10-01
... contract with economic price adjustment may be used when (i) there is serious doubt concerning the... limited to contingencies beyond the contractor's control. For use of economic price adjustment in sealed bid contracts, see 14.408-4. (a) In establishing the base level from which adjustment will be made...
Bevel Gear Driver and Method Having Torque Limit Selection
NASA Technical Reports Server (NTRS)
Cook, Joseph S., Jr. (Inventor)
1997-01-01
Methods and apparatus are provided for a torque driver including an axially displaceable gear with a biasing assembly to bias the displaceable gear into an engagement position. A rotatable cap is provided with a micrometer dial to select a desired output torque. An intermediate bevel gear assembly is disposed between an input gear and an output gear. A gear tooth profile provides a separation force that overcomes the bias to limit torque at a desired torque limit. The torque limit is adjustable and may be adjusted manually or automatically depending on the type of biasing assembly provided. A clutch assembly automatically limits axial force applied to a fastener by the operator to avoid alteration of the desired torque limit.
[Sleep duration and functional limitations in older adult].
Eumann Mesas, Arthur; López-García, Esther; Rodríguez-Artalejo, Fernando
2011-04-30
To examine the association between sleep duration and functional limitation in older adults from Spain. Cross-sectional study with 3,708 individuals representative of the non-institutionalized population aged ≥ 60 years in Spain. Sleep duration was self-reported, and the functional limitations in the instrumental activities of daily living (IADL) were assessed. Functional limitations in IADL were identified in 1,424 (38.4%) participants. In analyses adjusted for sociodemographic and lifestyle variables, the percentage of participants with limitation in IADL was higher in those who slept ≤ 5 hours (odds ratio [OR]=1.56; 95% confidence interval [CI]=1.18-2.06) or ≥ 10 hours (OR=2.08; 95%CI=1.67-2.60; p for trend<0.001) than in those who slept 8 hours. The association between long sleep (≥ 10 hours) and functional limitations held even after adjustment for comorbidity and sleep quality (OR=1.77; 95%CI=1.38-2.28) while the association between short sleep (≤ 5 hours) and functional limitation no longer held after this adjustment (OR=1.10; 95%CI=0.80-1.50). In older adults, long sleep duration is a marker of functional limitations independent of comorbidity. Copyright © 2010 Elsevier España, S.L. All rights reserved.
Tedeschi, L O; Seo, S; Fox, D G; Ruiz, R
2006-12-01
Current ration formulation systems used to formulate diets on farms and to evaluate experimental data estimate metabolizable energy (ME)-allowable and metabolizable protein (MP)-allowable milk production from the intake above animal requirements for maintenance, pregnancy, and growth. The changes in body reserves, measured via the body condition score (BCS), are not accounted for in predicting ME and MP balances. This paper presents 2 empirical models developed to adjust predicted diet-allowable milk production based on changes in BCS. Empirical reserves model 1 was based on the reserves model described by the 2001 National Research Council (NRC) Nutrient Requirements of Dairy Cattle, whereas empirical reserves model 2 was developed based on published data of body weight and composition changes in lactating dairy cows. A database containing 134 individually fed lactating dairy cows from 3 trials was used to evaluate these adjustments in milk prediction based on predicted first-limiting ME or MP by the 2001 Dairy NRC and Cornell Net Carbohydrate and Protein System models. The analysis of first-limiting ME or MP milk production without adjustments for BCS changes indicated that the predictions of both models were consistent (r(2) of the regression between observed and model-predicted values of 0.90 and 0.85), had mean biases different from zero (12.3 and 5.34%), and had moderate but different roots of mean square errors of prediction (5.42 and 4.77 kg/d) for the 2001 NRC model and the Cornell Net Carbohydrate and Protein System model, respectively. The adjustment of first-limiting ME- or MP-allowable milk to BCS changes improved the precision and accuracy of both models. We further investigated 2 methods of adjustment; the first method used only the first and last BCS values, whereas the second method used the mean of weekly BCS values to adjust ME- and MP-allowable milk production. The adjustment to BCS changes based on first and last BCS values was more accurate than the adjustment to BCS based on the mean of all BCS values, suggesting that adjusting milk production for mean weekly variations in BCS added more variability to model-predicted milk production. We concluded that both models adequately predicted the first-limiting ME- or MP-allowable milk after adjusting for changes in BCS.
7 CFR 1400.500 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-01-01
... SUBSEQUENT CROP, PROGRAM, OR FISCAL YEARS Average Adjusted Gross Income Limitation § 1400.500 Applicability... program payments or benefits described in § 1400.1 if the average adjusted gross income of the person or... average adjusted gross nonfarm income as defined in § 1400.3 that exceeds $500,000 will not be eligible to...
7 CFR 1400.500 - Applicability.
Code of Federal Regulations, 2011 CFR
2011-01-01
... SUBSEQUENT CROP, PROGRAM, OR FISCAL YEARS Average Adjusted Gross Income Limitation § 1400.500 Applicability... program payments or benefits described in § 1400.1 if the average adjusted gross income of the person or... average adjusted gross nonfarm income as defined in § 1400.3 that exceeds $500,000 will not be eligible to...
48 CFR 12.207 - Contract type.
Code of Federal Regulations, 2011 CFR
2011-10-01
... contracts or fixed-price contracts with economic price adjustment for the acquisition of commercial items... fixed-price with economic price adjustment contracts (e.g., by limiting the value or length of the time... maximize the use of firm-fixed-price or fixed-price with economic price adjustment contracts on future...
Quantifying the effects of disorder on switching of perpendicular spin ice arrays
NASA Astrophysics Data System (ADS)
Kempinger, Susan; Fraleigh, Robert; Lammert, Paul; Crespi, Vincent; Samarth, Nitin; Zhang, Sheng; Schiffer, Peter
There is much contemporary interest in probing custom designed, frustrated systems such as artificial spin ice. To that end, we study arrays of lithographically patterned, single-domain Pt/Co multilayer islands. Due to the perpendicular anisotropy of these materials, we are able to use diffraction-limited magneto-optical Kerr effect microscopy to access the magnetic state in situ with an applied field. As we tune the interaction strength by adjusting the lattice spacing, we observe the switching field distribution broadening with increasing dipolar interactions. Using a simple mathematical analysis we extract the intrinsic disorder (the disorder that would be present without interactions) from these switching field distributions. We also characterize the intrinsic disorder by systematically removing neighbor effects from the switching field distribution. Understanding this disorder contribution as well as the interaction strength allows us to more accurately characterize the moment correlation. This project was funded by the US Department of Energy, Office of Basic Energy Sciences, Materials Sciences and Engineering Division under Grant No. DE- SC0010778
Sanzolone, R.F.; Chao, T.T.; Crenshaw, G.L.
1979-01-01
An atomic-absorption spectrometric method is reported for the determination of cobalt, nickel, and copper in a variety of geological materials including iron- and manganese-rich, and calcareous samples. The sample is decomposed with HP-HNO3 and the residue is dissolved in hydrochloric acid. Ammonium fluoride is added to mask iron and 'aluminum. After adjustment to pH 6, cobalt, nickel, and copper are chelated with sodium diethyl-dithiocarbamate and extracted into methyl isobutyl ketone. The sample is set aside for 24 h before analysis to remove interferences from manganese. For a 0.200-g sample, the limits of determination are 5-1000 ppm for Co, Ni, and Cu. As much as 50% Fe, 25% Mn or Ca, 20% Al and 10% Na, K, or Mg in the sample either individually or in various combinations do not interfere. Results obtained on five U.S. Geological Survey rock standards are in general agreement with values reported in the literature. ?? 1979.
Virtual tryout planning in automotive industry based on simulation metamodels
NASA Astrophysics Data System (ADS)
Harsch, D.; Heingärtner, J.; Hortig, D.; Hora, P.
2016-11-01
Deep drawn sheet metal parts are increasingly designed to the feasibility limit, thus achieving a robust manufacturing is often challenging. The fluctuation of process and material properties often lead to robustness problems. Therefore, numerical simulations are used to detect the critical regions. To enhance the agreement with the real process conditions, the material data are acquired through a variety of experiments. Furthermore, the force distribution is taken into account. The simulation metamodel contains the virtual knowledge of a particular forming process, which is determined based on a series of finite element simulations with variable input parameters. Based on the metamodels, virtual process windows can be displayed for different configurations. This helps to improve the operating point as well as to adjust process settings in case the process becomes unstable. Furthermore, the time of tool tryout can be shortened due to transfer of the virtual knowledge contained in the metamodels on the optimisation of the drawbeads. This allows the tool manufacturer to focus on the essential, to save time and to recognize complex relationships.
Optically reconfigurable metasurfaces and photonic devices based on phase change materials
NASA Astrophysics Data System (ADS)
Wang, Qian; Rogers, Edward T. F.; Gholipour, Behrad; Wang, Chih-Ming; Yuan, Guanghui; Teng, Jinghua; Zheludev, Nikolay I.
2016-01-01
Photonic components with adjustable parameters, such as variable-focal-length lenses or spectral filters, which can change functionality upon optical stimulation, could offer numerous useful applications. Tuning of such components is conventionally achieved by either micro- or nanomechanical actuation of their constituent parts, by stretching or by heating. Here, we report a novel approach for making reconfigurable optical components that are created with light in a non-volatile and reversible fashion. Such components are written, erased and rewritten as two-dimensional binary or greyscale patterns into a nanoscale film of phase-change material by inducing a refractive-index-changing phase transition with tailored trains of femtosecond pulses. We combine germanium-antimony-tellurium-based films with a diffraction-limited resolution optical writing process to demonstrate a variety of devices: visible-range reconfigurable bichromatic and multi-focus Fresnel zone plates, a super-oscillatory lens with subwavelength focus, a greyscale hologram, and a dielectric metamaterial with on-demand reflection and transmission resonances.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-14
...As mandated by provisions of the Federal Election Campaign Act of 1971, as amended (``FECA'' or ``the Act''), the Federal Election Commission (``FEC'' or ``the Commission'') is adjusting certain contribution and expenditure limits and the lobbyist bundling disclosure threshold set forth in the Act, to index the amounts for inflation. Additional details appear in the supplemental information that follows.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-06
...As mandated by provisions of the Federal Election Campaign Act of 1971, as amended (``FECA'' or ``the Act''), the Federal Election Commission (``FEC'' or ``the Commission'') is adjusting certain contribution and expenditure limitations and the lobbyist bundling disclosure threshold set forth in the Act, to index the amounts for inflation. Additional details appear in the supplemental information that follows.
Kazemi, Mahmood; Rohanian, Ahmad; Monzavi, Abbas; Nazari, Mohammad Sadegh
2013-01-01
Objective: Accurate delivery of torque to implant screws is critical to generate ideal preload in the screw joint and to offer protection against screw loosening. Mechanical torque-limiting devices (MTLDs) are available for this reason. In this study, the accuracy of one type of friction-style and two types of spring-style MTLDs at baseline, following fatigue conditions and sterilization processes were determined. Materials and Methods: Five unused MTLDs were selected from each of Straumann (ITI), Astra TECH and CWM systems. To measure the output of each MTLD, a digital torque gauge with a 3-jaw chuck was used to hold the driver. Force was applied to the MTLDs until either the friction styles released at a pre-calibrated torque value or the spring styles flexed to a pre-calibrated limit (target torque value). The peak torque value was recorded and the procedure was repeated 5 times for each MTLD. Then MTLDs were subjected to fatigue conditions at 500 and 1000 times and steam sterilization processes at 50 and 100 times and the peak torque value was recorded again at each stage. Results: Adjusted difference between measured torque values and target torque values differed significantly between stages for all 3 systems. Adjusted difference did not differ significantly between systems at all stages, but differed significantly between two different styles at baseline and 500 times fatigue stages. Conclusion: Straumann (ITI) devices differed minimally from target torque values at all stages. MTLDs with Spring-style were significantly more accurate than Friction-style device in achieving their target torque values at baseline and 500 times fatigue. PMID:23724209
Barton, David M.
1991-01-01
A switch for reacting quickly to a neutron emission. A rod consisting of fissionable material is located inside a vacuum tight body. An adjustable contact is located coaxially at an adjustable distance from one end of the rod. Electrical leads are connected to the rod and to the adjustable contact. With a vacuum drawn inside the body, a neutron bombardment striking the rod causes it to heat and expand longitudinally until it comes into contact with the adjustable contact. This circuit closing occurs within a period of a few microseconds.
Understanding heart rate alarm adjustment in the intensive care units through an analytical approach
Pelter, Michele M.; Drew, Barbara J.; Palacios, Jorge Arroyo; Bai, Yong; Stannard, Daphne; Aldrich, J. Matt; Hu, Xiao
2017-01-01
Background Heart rate (HR) alarms are prevalent in ICU, and these parameters are configurable. Not much is known about nursing behavior associated with tailoring HR alarm parameters to individual patients to reduce clinical alarm fatigue. Objectives To understand the relationship between heart rate (HR) alarms and adjustments to reduce unnecessary heart rate alarms. Methods Retrospective, quantitative analysis of an adjudicated database using analytical approaches to understand behaviors surrounding parameter HR alarm adjustments. Patients were sampled from five adult ICUs (77 beds) over one month at a quaternary care university medical center. A total of 337 of 461 ICU patients had HR alarms with 53.7% male, mean age 60.3 years, and 39% non-Caucasian. Default HR alarm parameters were 50 and 130 beats per minute (bpm). The occurrence of each alarm, vital signs, and physiologic waveforms was stored in a relational database (SQL server). Results There were 23,624 HR alarms for analysis, with 65.4% exceeding the upper heart rate limit. Only 51% of patients with HR alarms had parameters adjusted, with a median upper limit change of +5 bpm and -1 bpm lower limit. The median time to first HR parameter adjustment was 17.9 hours, without reduction in alarms occurrence (p = 0.57). Conclusions HR alarms are prevalent in ICU, and half of HR alarm settings remain at default. There is a long delay between HR alarms and parameters changes, with insufficient changes to decrease HR alarms. Increasing frequency of HR alarms shortens the time to first adjustment. Best practice guidelines for HR alarm limits are needed to reduce alarm fatigue and improve monitoring precision. PMID:29176776
Legros, S.; Mialet-Serra, I.; Caliman, J.-P.; Siregar, F. A.; Clement-Vidal, A.; Fabre, D.; Dingkuhn, M.
2009-01-01
Background and Aims Despite its simple architecture and small phenotypic plasticity, oil palm has complex phenology and source–sink interactions. Phytomers appear in regular succession but their development takes years, involving long lag periods between environmental influences and their effects on sinks. Plant adjustments to resulting source–sink imbalances are poorly understood. This study investigated oil palm adjustments to imbalances caused by severe fruit pruning. Methods An experiment with two treatments (control and complete fruit pruning) during 22 months in 2006–2008) and six replications per treatment was conducted in Indonesia. Phenology, growth of above-ground vegetative and reproductive organs, leaf morphology, inflorescence sex differentiation, dynamics of non-structural carbohydrate reserves and light-saturated net photosynthesis (Amax) were monitored. Key Results Artificial sink limitation by complete fruit pruning accelerated development rate, resulting in higher phytomer, leaf and inflorescence numbers. Leaf size and morphology remained unchanged. Complete fruit pruning also suppressed the abortion of male inflorescences, estimated to be triggered at about 16 months before bunch maturity. The number of female inflorescences increased after an estimated lag of 24–26 months, corresponding to time from sex differentiation to bunch maturity. The most important adjustment process was increased assimilate storage in the stem, attaining nearly 50 % of dry weight in the stem top, mainly as starch, whereas glucose, which in controls was the most abundant non-structural carbohydrate stored in oil palm, decreased. Conclusions The development rate of oil palm is in part controlled by source–sink relationships. Although increased rate of development and proportion of female inflorescences constituted observed adjustments to sink limitation, the low plasticity of plant architecture (constant leaf size, absence of branching) limited compensatory growth. Non-structural carbohydrate storage was thus the main adjustment process. PMID:19748908
An Ergonomic Evaluation of Aircraft Pilot Seats
NASA Astrophysics Data System (ADS)
Andrade, Yolanda Nicole
Seat comfort has become increasingly important in today's society as we spend more time at consoles, instrument panels, or just online. However, seat comfort is hard to define and difficult to measure. Several measures both objective and subjective were used to evaluate seat comfort in commercially available average pilot seats. Three pilot seats, which had the same material and similar adjustments but different physical attributes, and a universal classroom seat, with different material and no adjustments, were compared by 20 volunteers using subjective and objective measures in a Latin square controlled repeated measures design. A Friedman's test was used to determine that both the comfort questionnaire and the body-map rating results were able to discriminate objective comfort levels between the seats. One-way repeated measures ANOVA tests were used to analyze both the objective tests, actigraph and pressure pad data. All results indicated that one seat was clearly the most comfortable and another, the classroom seat was clearly the most uncomfortable seat. Furthermore, the overall comments per seat were compiled and compared to Fazlollahtabar's 2010) predictive automobile seat comfort theory to determine which factors influence comfort perception. The use of both subjective and objective data can better distinguish comfort from one seat over the other. These results have implications for future tests of seats that will be used for long durations. Limitations and future recommendations are discussed later in the paper. An interesting finding may explain why pressure pad data are typically seemingly at odds with subjective measures of seat comfort.
NASA Astrophysics Data System (ADS)
Zhang, Chuan; Luo, Wenjun; Wen, Xin; Guan, Zhongjie; Zou, Zhigang
2017-11-01
P-type Cu(In,Ga)S2 semiconductors are promising candidates to be used as photocathodes for solar water splitting. Porous structures have been widely used to improve the performances of photoelectrodes due to good minority carrier transport. However, a porous photoelectrode has longer transport distance of majority carriers, which limits its performance. Controlling pore volume of a photoelectrode can balance minority and majority carrier transport and improve the performance. Here, a porous Cu(In,Ga)S2 film is prepared by facile spin-coating method. The pore volume of Cu(In,Ga)S2 film is controlled by adjusting relative humidity (RH) of air during spin-coating process. Further studies suggest that polyvinyl acetate (PVAc) in precursor solution is a humidity sensitive polymer and plays a key role to form different pore volume. The 40% RH sample has the best performance due to its optimum pore volume. After further coated with CdS surface passivation layer and Pt electrocatalyst on the surface, a 40% RH Cu(In,Ga)S2 photocathode indicates a photocurrent density of 8.6 mA cm-2 at 0 V RHE, which is one of the highest photocurrents of Cu(In,Ga)S2 photocathodes. This new strategy for adjusting pore volume is also suitable to prepare other solution-processed inorganic materials.
Relativistic viscoelastic fluid mechanics.
Fukuma, Masafumi; Sakatani, Yuho
2011-08-01
A detailed study is carried out for the relativistic theory of viscoelasticity which was recently constructed on the basis of Onsager's linear nonequilibrium thermodynamics. After rederiving the theory using a local argument with the entropy current, we show that this theory universally reduces to the standard relativistic Navier-Stokes fluid mechanics in the long time limit. Since effects of elasticity are taken into account, the dynamics at short time scales is modified from that given by the Navier-Stokes equations, so that acausal problems intrinsic to relativistic Navier-Stokes fluids are significantly remedied. We in particular show that the wave equations for the propagation of disturbance around a hydrostatic equilibrium in Minkowski space-time become symmetric hyperbolic for some range of parameters, so that the model is free of acausality problems. This observation suggests that the relativistic viscoelastic model with such parameters can be regarded as a causal completion of relativistic Navier-Stokes fluid mechanics. By adjusting parameters to various values, this theory can treat a wide variety of materials including elastic materials, Maxwell materials, Kelvin-Voigt materials, and (a nonlinearly generalized version of) simplified Israel-Stewart fluids, and thus we expect the theory to be the most universal description of single-component relativistic continuum materials. We also show that the presence of strains and the corresponding change in temperature are naturally unified through the Tolman law in a generally covariant description of continuum mechanics.
Hydraulic conductivity of fly ash-sewage sludge mixes for use in landfill cover liners.
Herrmann, Inga; Svensson, Malin; Ecke, Holger; Kumpiene, Jurate; Maurice, Christian; Andreas, Lale; Lagerkvist, Anders
2009-08-01
Secondary materials could help meeting the increasing demand of landfill cover liner materials. In this study, the effect of compaction energy, water content, ash ratio, freezing, drying and biological activity on the hydraulic conductivity of two fly ash-sewage sludge mixes was investigated using a 2(7-1) fractional factorial design. The aim was to identify the factors that influence hydraulic conductivity, to quantify their effects and to assess how a sufficiently low hydraulic conductivity can be achieved. The factors compaction energy and drying, as well as the factor interactions material x ash ratio and ash ratio x compaction energy affected hydraulic conductivity significantly (alpha=0.05). Freezing on five freeze-thaw cycles did not affect hydraulic conductivity. Water content affected hydraulic conductivity only initially. The hydraulic conductivity data were modelled using multiple linear regression. The derived models were reliable as indicated by R(adjusted)(2) values between 0.75 and 0.86. Independent on the ash ratio and the material, hydraulic conductivity was predicted to be between 1.7 x 10(-11)m s(-1) and 8.9 x 10(-10)m s(-1) if the compaction energy was 2.4 J cm(-3), the ash ratio between 20% and 75% and drying did not occur. Thus, the investigated materials met the limit value for non-hazardous waste landfills of 10(-9)m s(-1).
Relativistic viscoelastic fluid mechanics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fukuma, Masafumi; Sakatani, Yuho
2011-08-15
A detailed study is carried out for the relativistic theory of viscoelasticity which was recently constructed on the basis of Onsager's linear nonequilibrium thermodynamics. After rederiving the theory using a local argument with the entropy current, we show that this theory universally reduces to the standard relativistic Navier-Stokes fluid mechanics in the long time limit. Since effects of elasticity are taken into account, the dynamics at short time scales is modified from that given by the Navier-Stokes equations, so that acausal problems intrinsic to relativistic Navier-Stokes fluids are significantly remedied. We in particular show that the wave equations for themore » propagation of disturbance around a hydrostatic equilibrium in Minkowski space-time become symmetric hyperbolic for some range of parameters, so that the model is free of acausality problems. This observation suggests that the relativistic viscoelastic model with such parameters can be regarded as a causal completion of relativistic Navier-Stokes fluid mechanics. By adjusting parameters to various values, this theory can treat a wide variety of materials including elastic materials, Maxwell materials, Kelvin-Voigt materials, and (a nonlinearly generalized version of) simplified Israel-Stewart fluids, and thus we expect the theory to be the most universal description of single-component relativistic continuum materials. We also show that the presence of strains and the corresponding change in temperature are naturally unified through the Tolman law in a generally covariant description of continuum mechanics.« less
Use of pre-pulse in laser spot welding of materials with high optical reflection
NASA Astrophysics Data System (ADS)
Mys, Ihor; Geiger, Manfred
2003-11-01
Laser micro welding has become a standard manufacturing technique, particularly in industry sectors, such as automotive and aerospace electronics or medical devices, where the requirements for strength, miniaturization and temperature resistance are constantly rising. So far the use of laser micro welding is limited due to the fluctuation of the quality of the welded joints, because the welding results for material with high optical reflection and thermal conductivity, such as copper and copper alloys, depend very strongly on the condition of the material surface. This paper presents investigations on the use of a laser pre-pulse in spot welding of electronic materials with Nd:YAG laser. In order to achieve reproducible joining results two strategies are followed-up. The first one utilizes a reflection-based process control for measuring the reflection during the short pre-pulse. The intensity of the reflected light is used to calculate an appropriated welding pulse power, which corresponds to the measured relative absorption. Adjustment of laser parameters according to the condition of the surface is done in real time before laser main pulse. A second possibility for the stabilization of copper welding is the employment of a short and powerful laser pre-pulse before laser main pulse. This pre-pulse affects the workpiece surface and creates more reproducible absorption conditions for the main pulse, independent from the initial situation on material surface.
26 CFR 301.6501(m)-1 - Tentative carryback adjustment assessment period.
Code of Federal Regulations, 2010 CFR
2010-04-01
... period. 301.6501(m)-1 Section 301.6501(m)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE... Assessment and Collection § 301.6501(m)-1 Tentative carryback adjustment assessment period. (a) Period of limitation after tentative carryback adjustment. (1) Under section 6501(m), in a case where an amount has...
26 CFR 301.6501(m)-1 - Tentative carryback adjustment assessment period.
Code of Federal Regulations, 2011 CFR
2011-04-01
... period. 301.6501(m)-1 Section 301.6501(m)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE... Assessment and Collection § 301.6501(m)-1 Tentative carryback adjustment assessment period. (a) Period of limitation after tentative carryback adjustment. (1) Under section 6501(m), in a case where an amount has...
76 FR 71559 - Acid Rain Program: Notice of Annual Adjustment Factors for Excess Emissions Penalty
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-18
... ENVIRONMENTAL PROTECTION AGENCY [FRL-9494-6] Acid Rain Program: Notice of Annual Adjustment... annual adjustment factors for excess emissions penalty. SUMMARY: The Acid Rain Program under title IV of... emissions for sources that do not meet their annual Acid Rain emissions limitations. This notice states the...
78 FR 64496 - Acid Rain Program: Notice of Annual Adjustment Factors for Excess Emissions Penalty
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-29
... ENVIRONMENTAL PROTECTION AGENCY [FRL-9902-14-OAR] Acid Rain Program: Notice of Annual Adjustment... annual adjustment factors for excess emissions penalty. SUMMARY: The Acid Rain Program under title IV of... emissions for sources that do not meet their annual Acid Rain emissions limitations. This notice states the...
26 CFR 1.415(d)-1 - Cost-of-living adjustments.
Code of Federal Regulations, 2012 CFR
2012-04-01
... effect before the January 1 adjustment) prior to January 1. Thus, where there is an increase in the...)(B)) in effect with respect to the distribution taking into account the section 415(d) adjustment, and the denominator of which is the limitation under section 415(b) in effect for the distribution...
26 CFR 1.415(d)-1 - Cost-of-living adjustments.
Code of Federal Regulations, 2010 CFR
2010-04-01
... effect before the January 1 adjustment) prior to January 1. Thus, where there is an increase in the...)(B)) in effect with respect to the distribution taking into account the section 415(d) adjustment, and the denominator of which is the limitation under section 415(b) in effect for the distribution...
26 CFR 1.415(d)-1 - Cost-of-living adjustments.
Code of Federal Regulations, 2013 CFR
2013-04-01
... effect before the January 1 adjustment) prior to January 1. Thus, where there is an increase in the...)(B)) in effect with respect to the distribution taking into account the section 415(d) adjustment, and the denominator of which is the limitation under section 415(b) in effect for the distribution...
26 CFR 1.415(d)-1 - Cost-of-living adjustments.
Code of Federal Regulations, 2011 CFR
2011-04-01
... effect before the January 1 adjustment) prior to January 1. Thus, where there is an increase in the...)(B)) in effect with respect to the distribution taking into account the section 415(d) adjustment, and the denominator of which is the limitation under section 415(b) in effect for the distribution...
26 CFR 1.415(d)-1 - Cost-of-living adjustments.
Code of Federal Regulations, 2014 CFR
2014-04-01
... effect before the January 1 adjustment) prior to January 1. Thus, where there is an increase in the...)(B)) in effect with respect to the distribution taking into account the section 415(d) adjustment, and the denominator of which is the limitation under section 415(b) in effect for the distribution...
NASA Astrophysics Data System (ADS)
Wang, Faming; Del Ferraro, Simona; Molinaro, Vincenzo; Morrissey, Matthew; Rossi, René
2014-09-01
Regional sweating patterns and body surface temperature differences exist between genders. Traditional sportswear made from one material and/or one fabric structure has a limited ability to provide athletes sufficient local wear comfort. Body mapping sportswear consists of one piece of multiple knit structure fabric or of different fabric pieces that may provide athletes better wear comfort. In this study, the `modular' body mapping sportswear was designed and subsequently assessed on a `Newton' type sweating manikin that operated in both constant temperature mode and thermophysiological model control mode. The performance of the modular body mapping sportswear kit and commercial products were also compared. The results demonstrated that such a modular body mapping sportswear kit can meet multiple wear/thermal comfort requirements in various environmental conditions. All body mapping clothing (BMC) presented limited global thermophysiological benefits for the wearers. Nevertheless, BMC showed evident improvements in adjusting local body heat exchanges and local thermal sensations.
Wang, Faming; Del Ferraro, Simona; Molinaro, Vincenzo; Morrissey, Matthew; Rossi, René
2014-09-01
Regional sweating patterns and body surface temperature differences exist between genders. Traditional sportswear made from one material and/or one fabric structure has a limited ability to provide athletes sufficient local wear comfort. Body mapping sportswear consists of one piece of multiple knit structure fabric or of different fabric pieces that may provide athletes better wear comfort. In this study, the 'modular' body mapping sportswear was designed and subsequently assessed on a 'Newton' type sweating manikin that operated in both constant temperature mode and thermophysiological model control mode. The performance of the modular body mapping sportswear kit and commercial products were also compared. The results demonstrated that such a modular body mapping sportswear kit can meet multiple wear/thermal comfort requirements in various environmental conditions. All body mapping clothing (BMC) presented limited global thermophysiological benefits for the wearers. Nevertheless, BMC showed evident improvements in adjusting local body heat exchanges and local thermal sensations.
Strategic Defense Initiative Organization adaptive structures program overview
NASA Astrophysics Data System (ADS)
Obal, Michael; Sater, Janet M.
In the currently envisioned architecture none of the Strategic Defense System (SDS) elements to be deployed will receive scheduled maintenance. Assessments of performance capability due to changes caused by the uncertain effects of environments will be difficult, at best. In addition, the system will have limited ability to adjust in order to maintain its required performance levels. The Materials and Structures Office of the Strategic Defense Initiative Organization (SDIO) has begun to address solutions to these potential difficulties via an adaptive structures technology program that combines health and environment monitoring with static and dynamic structural control. Conceivable system benefits include improved target tracking and hit-to-kill performance, on-orbit system health monitoring and reporting, and threat attack warning and assessment.
Limitations for a Successful Army Leader Development Strategy
2013-05-23
the Army, the programs for managing officers to be adjusted to support the strategy, and the policies that constrain the programs to be adjusted...officer management programs exposes a number of policies that detrimentally limit the accomplishment of the objectives. The effectiveness of the ALDS...system. Commanders would fight to get their best officers to school as early as possible as a reward and would develop aggressive development programs
Li, Liang; Liu, Na; Xu, Ziqi; Chen, Qi; Wang, Xindong; Zhou, Huanping
2017-09-26
Mixed anion/cation perovskites absorber has been recently implemented to construct highly efficient single junction solar cells and tandem devices. However, considerable efforts are still required to map the composition-property relationship of the mixed perovskites absorber, which is essential to facilitate device design. Here we report the intensive exploration of mixed-cation perovskites in their compositional space with the assistance of a rational mixture design (MD) methods. Different from the previous linear search of the cation ratios, it is found that by employing the MD methods, the ternary composition can be tuned simultaneously following simplex lattice designs or simplex-centroid designs, which enable significantly reduced experiment/sampling size to unveil the composition-property relationship for mixed perovskite materials and to boost the resultant device efficiency. We illustrated the composition-property relationship of the mixed perovskites in multidimension and achieved an optimized power conversion efficiency of 20.99% in the corresponding device. Moreover, the method is demonstrated to be feasible to help adjust the bandgap through rational materials design, which can be further extended to other materials systems, not limited in polycrystalline perovskites films for photovoltaic applications only.
Laser micro-machining strategies for transparent brittle materials using ultrashort pulsed lasers
NASA Astrophysics Data System (ADS)
Bernard, Benjamin; Matylitsky, Victor
2017-02-01
Cutting and drilling of transparent materials using short pulsed laser systems are important industrial production processes. Applications ranging from sapphire cutting, hardened glass processing, and flat panel display cutting, to diamond processing are possible. The ablation process using a Gaussian laser beam incident on the topside of a sample with several parallel overlapping lines leads to a V-shaped structured groove. This limits the structuring depth for a given kerf width. The unique possibility for transparent materials to start the ablation process from the backside of the sample is a well-known strategy to improve the aspect ratio of the ablated features. This work compares the achievable groove depth depending on the kerf width for front-side and back-side ablation and presents the best relation between the kerf width and number of overscans. Additionally, the influence of the number of pulses in one burst train on the ablation efficiency is investigated. The experiments were carried out using Spirit HE laser from Spectra-Physics, with the features of adjustable pulse duration from <400 fs to 10 ps, three different repetition rates (100 kHz, 200 kHz and 400 kHz) and average output powers of >16 W ( at 1040 nm wavelength).
Pin Load Control Applied to Retractable Pin Tool Technology and its Characterization
NASA Technical Reports Server (NTRS)
Oelgoetz, Peter A.
2000-01-01
Until the development of retractable pin tool (RPT) technology, friction stir welding (FSW) was limited to constant thickness joining of aluminum materials and the choices of keyhole elimination focused on traditional fusion and plug weld repair techniques. An invention, US Patent Number 5,893,507, "Auto-Adjustable Pin Tool for Friction Stir Welding" assigned to NASA, demonstrated an approach to resolve these serious drawbacks. This approach brings forth a technique that allows the crater, or keyhole, to be closed out automatically at the end of the weld joint without adding any additional equipment or material. Also the probe length can be varied automatically in the weld joint to compensate for material thickness changes, such as, in a tapered joint. This paper reports the effects of pin extension and retraction rates in the weld joint and its correlation to weld quality. The investigation utilized a pin load-detecting device that was integrated in the Phase 2A RPT designed by Boeing for NASA/MSFC. The RPT modification provided pin load data that was accessed and used to eliminate root side indications and determine pin manipulation rates necessary to produce consistence homogeneous joints.
Pin Load Control Applied to Retractable Pin Tool Technology and its Characterization
NASA Technical Reports Server (NTRS)
Oelgoetz, Peter
2000-01-01
Until the development of retractable pin tool (RPT) technology, friction stir welding (FSW) was limited to constant thickness joining of aluminum materials and the choices of keyhole elimination focused on traditional fusion and plug weld repair techniques. An invention, US Patent Number 5,893.507, "Auto-Adjustable Pin Tool for Friction Stir Welding" assigned to NASA, demonstrated an approach to resolve these serious drawbacks. This approach brings forth a technique that allows the crater, or keyhole, to be closed out automatically at the end of the weld joint without adding any additional equipment or material. Also the probe length can be varied automatically in the weld joint to compensate for material thickness changes, such as, in a tapered joint. This paper reports the effects of pin extension and retraction rates in the weld joint and its correlation to weld quality. The investigation utilized a pin load-detecting device that was integrated in the Phase 2A RPT designed by Boeing for NASA/MSFC. The RPT modification provided pin load data that was accessed and used to eliminate root side indications and determine pin manipulation rates necessary to produce consistence homogeneous joints.
Pin Load Control Applied to Retractable Pin Tool Technology and Its Characterization
NASA Technical Reports Server (NTRS)
Olegoetz, P.
1999-01-01
Until the development of retractable pin tool (RPT) technology, friction stir welding (FSW) was limited to constant thickness joining of aluminum materials and the choices of keyhole elimination focused on traditional fusion and plug weld repair techniques. An invention, US Patent Number 5,893,507, "Auto-Adjustable Pin Tool for Friction Stir Welding" assigned to NASA, demonstrated an approach to resolve these serious drawbacks. This approach brings forth a technique that allows the crater, or keyhole, to be closed out automatically at the end of the weld joint without adding any additional equipment or material. Also the probe length can be varied automatically in the weld joint to compensate for material thickness changes, such as, in a tapered joint. This paper reports the effects of pin extension and retraction rates in the weld joint and its correlation to weld quality. The investigation utilized a pin load-detecting device that was integrated in the Phase IIA RPT designed by Boeing for NASA/MSFC. The RPT modification provided pin load data that was accessed and used to eliminate root side indications and determine pin manipulation rates necessary to produce consistence homogeneous joints.
NASA Technical Reports Server (NTRS)
Lee, J. A.; Carter, R. W.; Ding, J.
1999-01-01
This technical memorandum describes an investigation of using friction stir welding (FSW) process for joining a variety of aluminum metal matrix composites (MMC's) reinforced with discontinuous silicon-carbide (SiC) particulate and functional gradient materials. Preliminary results show that FSW is feasible to weld aluminum MMC to MMC or to aluminum-lithium 2195 if the SiC reinforcement is <25 percent by volume fraction. However, a softening in the heat-affected zone was observed and is known to be one of the major limiting factors for joint strength. The pin tool's material is made from a low-cost steel tool H-13 material, and the pin tool's wear was excessive such that the pin tool length has to be manually adjusted for every 5 ft of weldment. Initially, boron-carbide coating was developed for pin tools, but it did not show a significant improvement in wear resistance. Basically, FSW is applicable mainly for butt joining of flat plates. Therefore, FSW of cylindrical articles such as a flange to a duct with practical diameters ranging from 2-5 in. must be fully demonstrated and compared with other proven MMC joining techniques for cylindrical articles.
Risk adjustment for comparing hospital quality with surgery: how many variables are needed?
Dimick, Justin B; Osborne, Nicholas H; Hall, Bruce L; Ko, Clifford Y; Birkmeyer, John D
2010-04-01
The American College of Surgeons' National Surgical Quality Improvement Program (ACS NSQIP) will soon be reporting procedure-specific outcomes, and hopes to reduce the burden of data collection by collecting fewer variables. We sought to determine whether these changes threaten the robustness of the risk adjustment of hospital quality comparisons. We used prospective, clinical data from the ACS NSQIP from 2005 to 2007 (184 hospitals, 74,887 patients). For the 5 general surgery operations in the procedure-specific NSQIP, we compared the ability of the full model (21 variables), an intermediate model (12 variables), and a limited model (5 variables) to predict patient outcomes and to risk-adjust hospital outcomes. The intermediate and limited models were comparable with the full model in all analyses. In the assessment of patient risk, the limited and full models had very similar discrimination at the patient level (C-indices for all 5 procedures combined of 0.93 versus 0.91 for mortality and 0.78 versus 0.76 for morbidity) and showed good calibration across strata of patient risk. In assessing hospital-specific outcomes, results from the limited and full-risk models were highly correlated for both mortality (range 0.94 to 0.99 across the 5 operations) and morbidity (range 0.96 to 0.99). Procedure-specific hospital quality measures can be adequately risk-adjusted with a limited number of variables. In the context of the ACS NSQIP, moving to a more limited model will dramatically reduce the burden of data collection for participating hospitals. Published by Elsevier Inc.
Roumanas, Eleni D
2010-03-01
The authors analyzed the dental records of 2780 Navy (cohort 1 = 1078 entered the Navy in 1997) and US Marine Corps recruits (cohort 2 =1053 entered the USMC in 1999-2000; cohort 3 = 649 entered the USMC in 2002-2005). The records were reviewed at 16 US Navy dental treatment facilities at the following time periods: cohort 1, 2001; cohort 2, 2002-2003; and cohort 3, 2005-2006. The mean age of the subjects was 20 years, and 85% were men. Only posterior teeth (not third molars) with amalgam or resin-based composite (including glass ionomer restorations) were evaluated. Teeth that had been restored with more than one material and restorations that did not involve the occlusal surface were excluded. The minimum follow-up time was 2 years with at least 2 periodic exams following the initial exam. The primary factor of interest was the type of restorative material (amalgam versus resin-based composite). Secondary factors included tooth number, number of restored surfaces (single or multiple), and caries risk of the patient. Caries risk status was defined using the Navy Dental Corps Oral Disease Risk Management protocol. The primary outcome measure of interest was the determination of the relative risk of replacement of an initially intact restoration during the subject's first years of military service. Restorations were classified as clinically acceptable or requiring replacement either as a result of new primary caries, secondary caries, defective restorations, or endodontic therapy. At the initial exam, 964 (15.2%) of the amalgam restorations and 199 (17.4%) of the resin-based composites required replacement and were excluded from further analysis. Of the remaining restorations, an additional 14.2% of the amalgam and 16.7% of the composite restorations required replacement during the observation period. The mean follow-up time was 3.0 years (cohort 1, 3.4 years; cohort 2, 3.1 years; cohort 3, 2.3 years). Replacement rates for resin-based composite restorations compared with amalgam were significantly higher owing to all causes (adjusted hazard ratio [HR], 1.28; P < .05) and for replacement owing to restoration failure (adjusted HR, 1.64; P < .01). Multiple surface restorations demonstrated higher rates of replacement than single surface restorations from all causes (adjusted HR, 1.39; P < .01) and for replacement of existing restorations (adjusted HR, 1.82; P < .01). High-caries-risk subjects experienced more than twice the risk of retreatment than did low-caries-risk subjects when considering all replacements (adjusted HR, 2.04; P < .01) and 50% higher risk of replacement of previously restored surfaces (adjusted HR, 1.48; P<.01) Approximately 30% of all posterior restorations required replacement either at the initial or subsequent exams during the observation period. The number of resin-based composite restorations requiring replacement was significantly higher than amalgam restorations. The authors concluded that because of the extra cost, time, and potential for increased frequency of replacement, posterior composite restorations should be limited to restorations of appropriate size and placed under meticulous restorative technique with strict adherence to manufacturer's instructions.
Montz, Ellen; Layton, Tim; Busch, Alisa B.; Ellis, Randall P.; Rose, Sherri; McGuire, Thomas G.
2016-01-01
Under the Affordable Care Act, the risk-adjustment program is designed to compensate health plans for enrolling people with poorer health status so that plans compete on cost and quality rather than the avoidance of high-cost individuals. This study examined health plan incentives to limit covered services for mental health and substance use disorders under the risk-adjustment system used in the health insurance Marketplaces. Through a simulation of the program on a population constructed to reflect Marketplace enrollees, we analyzed the cost consequences for plans enrolling people with mental health and substance use disorders. Our assessment points to systematic underpayment to plans for people with these diagnoses. We document how Marketplace risk adjustment does not remove incentives for plans to limit coverage for services associated with mental health and substance use disorders. Adding mental health and substance use diagnoses used in Medicare Part D risk adjustment is one potential policy step toward addressing this problem in the Marketplaces. PMID:27269018
Choosing effective patient education materials
Your patient's preferences can guide your choice of education materials and methods. Find out how your patient ... aware that you may need to adjust your education plan based on the patient's health status and ...
Politics of North Korean Refugees and Regional Security Implications
2009-06-01
in material adjustment and success in mental adjustment is also partial adjustment, identified as “ acculturation .” Failure in both components is...hours on mental and physical health ; 2) 130 hours of vocational training and counseling in collaboration with the Ministry of Labor; 3) 90 hours of...delicate political balance among the Six-Party nations. How each country addresses this issue can affect its future influence within the region
Recent Progress in Adjustable X-ray Optics for Astronomy
NASA Technical Reports Server (NTRS)
Reid, Paul B.; Allured, Ryan; Cotroneo, Vincenzo; McMuldroch, Stuart; Marquez, Vanessa; Schwartz, Daniel A.; Vikhlinin, Alexey; ODell, Stephen L.; Ramsey, Brian; Trolier-McKinstry, Susan;
2014-01-01
Two adjustable X-ray optics approaches are being developed for thin grazing incidence optics for astronomy. The first approach employs thin film piezoelectric material sputter deposited as a continuous layer on the back of thin, lightweight Wolter-I mirror segments. The piezoelectric material is used to correct mirror figure errors from fabrication, mounting/alignment, and any ground to orbit changes. The goal of this technology is to produce Wolter mirror segment pairs corrected to 0.5 arc sec image resolution. With the combination of high angular resolution and lightweight, this mirror technology is suitable for the Square Meter Arc Second Resolution Telescope for X-rays (SMART-X) mission concept.. The second approach makes use of electrostrictive adjusters and full shell nickel/cobalt electroplated replication mirrors. An array of radial adjusters is used to deform the full shells to correct the lowest order axial and azimuthal errors, improving imaging performance from the 10 - 15 arc sec level to 5 arc sec. We report on recent developments in both technologies. In particular, we discuss the use of insitu strain gauges on the thin piezo film mirrors for use as feedback on piezoelectric adjuster functionality, including their use for on-orbit figure correction. We also report on the first tests of full shell nickel/cobalt mirror correction with radial adjusters.
Mother Positivity and Family Adjustment in Households with Children with a Serious Disability
ERIC Educational Resources Information Center
Trute, Barry; Benzies, Karen M.; Worthington, Catherine
2012-01-01
Only limited attention has been given to parent coping resources in the positive adjustment of families of children with a disability. This study is the first to explore maternal positivity as a psychological coping resource related to family adjustment in these families. Consistent with broaden-and-build theory and prior positivity research,…
47 CFR 27.53 - Emission limits.
Code of Federal Regulations, 2013 CFR
2013-10-01
... adjusted to indicate spectral energy in a 6.25 kHz segment. (d) For operations in the 758-763 MHz and 788... reading taken with any resolution bandwidth setting should be adjusted to indicate spectral energy in a 6... setting should be adjusted to indicate spectral energy in a 6.25 kHz segment; (5) Compliance with the...
10 CFR 35.605 - Installation, maintenance, adjustment, and repair.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Installation, maintenance, adjustment, and repair. 35.605 Section 35.605 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.605...
45 CFR 1170.44 - Academic adjustments.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 45 Public Welfare 3 2014-10-01 2014-10-01 false Academic adjustments. 1170.44 Section 1170.44 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL FOUNDATION ON THE ARTS AND THE... materials available to students with hearing impairments, readers in libraries for students with visual...
45 CFR 1170.44 - Academic adjustments.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 45 Public Welfare 3 2012-10-01 2012-10-01 false Academic adjustments. 1170.44 Section 1170.44 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL FOUNDATION ON THE ARTS AND THE... materials available to students with hearing impairments, readers in libraries for students with visual...
45 CFR 1170.44 - Academic adjustments.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 45 Public Welfare 3 2013-10-01 2013-10-01 false Academic adjustments. 1170.44 Section 1170.44 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL FOUNDATION ON THE ARTS AND THE... materials available to students with hearing impairments, readers in libraries for students with visual...
10 CFR 35.605 - Installation, maintenance, adjustment, and repair.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Installation, maintenance, adjustment, and repair. 35.605 Section 35.605 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.605...
10 CFR 35.605 - Installation, maintenance, adjustment, and repair.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Installation, maintenance, adjustment, and repair. 35.605 Section 35.605 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.605...
10 CFR 35.605 - Installation, maintenance, adjustment, and repair.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Installation, maintenance, adjustment, and repair. 35.605 Section 35.605 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.605...
10 CFR 35.605 - Installation, maintenance, adjustment, and repair.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Installation, maintenance, adjustment, and repair. 35.605 Section 35.605 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.605...
NASA Technical Reports Server (NTRS)
Ding, R. Jeffrey; Oelgoetz, Peter A.
1999-01-01
The "Auto-Adjustable Pin Tool for Friction Stir Welding", was developed at The Marshall Space Flight Center to address process deficiencies unique to the FSW process. The auto-adjustable pin tool, also called the retractable pin-tool (R.PT) automatically withdraws the welding probe of the pin-tool into the pin-tool's shoulder. The primary function of the auto-adjustable pin-tool is to allow for keyhole closeout, necessary for circumferential welding and localized weld repair, and, automated pin-length adjustment for the welding of tapered material thickness. An overview of the RPT hardware is presented. The paper follows with studies conducted using the RPT. The RPT was used to simulate two capabilities; welding tapered material thickness and closing out the keyhole in a circumferential weld. The retracted pin-tool regions in aluminum- lithium 2195 friction stir weldments were studied through mechanical property testing and metallurgical sectioning. Correlation's can be =de between retractable pin-tool programmed parameters, process parameters, microstructure, and resulting weld quality.
Cho, Min-Chul; Kim, So Young; Jeong, Tae-Dong; Lee, Woochang; Chun, Sail; Min, Won-Ki
2014-11-01
Verification of new lot reagent's suitability is necessary to ensure that results for patients' samples are consistent before and after reagent lot changes. A typical procedure is to measure results of some patients' samples along with quality control (QC) materials. In this study, the results of patients' samples and QC materials in reagent lot changes were analysed. In addition, the opinion regarding QC target range adjustment along with reagent lot changes was proposed. Patients' sample and QC material results of 360 reagent lot change events involving 61 analytes and eight instrument platforms were analysed. The between-lot differences for the patients' samples (ΔP) and the QC materials (ΔQC) were tested by Mann-Whitney U tests. The size of the between-lot differences in the QC data was calculated as multiples of standard deviation (SD). The ΔP and ΔQC values only differed significantly in 7.8% of the reagent lot change events. This frequency was not affected by the assay principle or the QC material source. One SD was proposed for the cutoff for maintaining pre-existing target range after reagent lot change. While non-commutable QC material results were infrequent in the present study, our data confirmed that QC materials have limited usefulness when assessing new reagent lots. Also a 1 SD standard for establishing a new QC target range after reagent lot change event was proposed. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
NASA Astrophysics Data System (ADS)
Cho, Jin Woo; Lee, Ju-hyoung; Kim, Sung-Wook; Choi, Eun-Kyeong
2017-04-01
Concrete which is generally used as filling material for a buried cavity has very high strength but significantly high self-load is considered its disadvantage. If it is used as filling material, the second collapse due to additional load, causing irreversible damage. If light-weighted foam and active feldspar are used to solve this problem, the second collapse can be prevented by reducing of self-load of filling material. In this study, the specimen was produced by mixing light-weighted foam, active feldspar and cement, and changes in the density, unconfined compressive strength and hydraulic conductivity were analyzed. Using the light-weighted foam could enable the adjustment of density of specimen between 0.5 g/cm3 and 1.7 g/cm3, and if the mixing ratio of the light-weighted foam increases, the specimen has more pores and smaller range of cross-sectional area. It is confirmed that it has direct correlation with the density, and if the specimen has more pores, the density of the specimen is lowered. The density of the specimen influences the unconfined compressive strength and the hydraulic conductivity, and it was also confirmed that the unconfined compressive strength could be adjusted between 0.6 MPa and 8 MPa and the hydraulic conductivity could be adjusted between 10-9cm/sec and 10-3cm/sec. These results indicated that we can adjust unconfined compressive strength and hydraulic conductivity of filling materials by changing the mixing amount of lightweight-weighted foam according to the requirements of the field condition. Keywords: filling material, buried cavity, light-weighted foam, feldspar Acknowledgement This research was supported by a Grant from a Strategic Research Project (Horizontal Drilling and Stabilization Technologies for Urban Search and Rescue (US&R) Operation) funded by the Korea Institute of Civil Engineering and Building Technology.
Health literacy and communication quality in health care organizations.
Wynia, Matthew K; Osborn, Chandra Y
2010-01-01
The relationship between limited health literacy and poor health may be due, in part, to poor communication quality within health care delivery organizations. We explored the relationship between health literacy status and receiving patient-centered communication in clinics and hospitals serving communication-vulnerable patient populations. Thirteen health care organizations nationwide distributed a survey to 5929 patients. All patients completed seven items assessing patient-centered communication. One third also completed three items assessing health literacy. The majority of patients had self-reported health literacy challenges, reporting problems learning about their medical condition because of difficulty understanding written information (53%), a lack of confidence in completing medical forms by themselves (61%), and needing someone to help them read hospital/clinic materials (57%). Logistic regression models showed that, after adjustment for patient demographic characteristics and health care organization type, patients with limited health literacy were 28% to 79% less likely than those with adequate health literacy to report their health care organization "always" provides patient-centered communication across seven communication items. Using a scaled composite of these items, limited health literacy remained associated with lower reported communication quality. These results suggest that improving communication quality in health care organizations might help to address the challenges facing patients with limited health literacy. They also highlight that efforts to address the needs of patients with limited health literacy should be sensitive to the range of communication challenges confronting these patients and their caregivers.
NASA Astrophysics Data System (ADS)
Zhu, Wenlong; Ma, Shoufeng; Tian, Junfang; Li, Geng
2016-11-01
Travelers' route adjustment behaviors in a congested road traffic network are acknowledged as a dynamic game process between them. Existing Proportional-Switch Adjustment Process (PSAP) models have been extensively investigated to characterize travelers' route choice behaviors; PSAP has concise structure and intuitive behavior rule. Unfortunately most of which have some limitations, i.e., the flow over adjustment problem for the discrete PSAP model, the absolute cost differences route adjustment problem, etc. This paper proposes a relative-Proportion-based Route Adjustment Process (rePRAP) maintains the advantages of PSAP and overcomes these limitations. The rePRAP describes the situation that travelers on higher cost route switch to those with lower cost at the rate that is unilaterally depended on the relative cost differences between higher cost route and its alternatives. It is verified to be consistent with the principle of the rational behavior adjustment process. The equivalence among user equilibrium, stationary path flow pattern and stationary link flow pattern is established, which can be applied to judge whether a given network traffic flow has reached UE or not by detecting the stationary or non-stationary state of link flow pattern. The stability theorem is proved by the Lyapunov function approach. A simple example is tested to demonstrate the effectiveness of the rePRAP model.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-27
... Civil Monetary Penalties for a Violation of the Hazardous Material Transportation Laws and Regulations... violations of Federal hazardous material transportation law or a regulation, order, special permit or approval issued under that law. The hazardous material transportation regulations are issued by the...
76 FR 30893 - Periodic Reporting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-27
... proportion to total ODIS-RPW sampling revenue. Petition, Supporting Material, at 3-6. The Postal Service... products by distributing PIHOP stamp adjustments in proportion to ODIS-RPW sampling stamp revenue and PIHOP meter adjustments in proportion to ODIS-RPW sampling meter revenue. Id. at 9. The details of the rather...
2014-01-01
Study Material properties and performance are governed by material molecular chemistry structures and molecular level interactions. Methods to...understand relationships between the material properties and performance and their correlation to the molecular level chemistry and morphology, and thus...find ways of manipulating and adjusting matters at the atomistic level in order to improve material performance are required. A computational material
Code of Federal Regulations, 2010 CFR
2010-04-01
... maintained. If the inconsistent position was not thus maintained, then the relationship must exist on the... 26 Internal Revenue 11 2010-04-01 2010-04-01 true Existence of relationship in case of adjustment... Between Years and Special Limitations § 1.1311(b)-3 Existence of relationship in case of adjustment by way...
Pearce, Anna; Whitehead, Margaret; Law, Catherine
2017-01-01
Background: Maternal employment has increased in European countries, but levels of employment are lower among mothers whose children have a limiting long-term illness or disability. However, we do not know whether having a child with a limiting illness prevents take-up or maintenance of paid employment or whether ‘common causes’, such as lack of qualifications or maternal disability lead to both maternal unemployment and childhood illness. Longitudinal data have the potential to distinguish between these. Methods: We analyzed four waves (3, 5, 7 and 11 years) of the Millennium Cohort Study (MCS) to examine the relationship between childhood limiting illness and maternal employment, unadjusted and adjusted for covariates. Multinomial regression models were used to test the association between child illness and trajectories of maternal employment. Fixed effects models assessed whether a new report of a child illness increased the odds of a mother exiting employment. Results: At every wave, maternal employment was more likely if the child did not have a limiting illness. After adjustment for covariates, childhood illness was associated with risks of continuous non-employment (adjusted Relative Risk Ratio = 1.46 [Confidence Interval: 1.21, 1.76]) or disrupted employment (aRRR = 1.26 [CI: 1.06, 1.49]), compared with entering or maintaining employment. If a child developed a limiting long-term illness, the likelihood of their mother exiting employment increased (adjusted Odds Ratio = 1.27 [CI: 1.05, 1.54]). Conclusions: ‘Common causes’ did not fully account for the association between child illness and maternal employment. Having a child with a limiting illness potentially reduces maternal employment opportunities. PMID:28177497
One-step method for the production of nanofluids
Kostic, Milivoje [Sycamore, IL; Golubovic, Mihajlo [Chicago, IL; Hull, John [Downers Grove, IL; Choi, Stephen U. S. [Naperville, IL
2011-08-16
A one step method and system for producing nanofluids by a nanoparticle-source evaporation and deposition of the evaporant into a base fluid. The base fluid such oil or ethylene glycol is placed in a rotating cylindrical drum having an adjustable heater-boat-evaporator and heat exchanger-cooler apparatus. As the drum rotates, a thin liquid layer is formed on the inside surface of the drum. An insulated heater-boat-evaporator having an evaporant material (nanoparticle-source) placed within its boat evaporator is adjustably positioned near a portion of the rotating thin liquid layer, the evaporant material being heated thereby evaporating a portion of the evaporant material and forming nanoparticles, the nanoparticles absorbed by the liquid film to form nanofluid.
Johri, Mira; Subramanian, S V; Sylvestre, Marie-Pierre; Dudeja, Sakshi; Chandra, Dinesh; Koné, Georges K; Sharma, Jitendar K; Pahwa, Smriti
2015-09-01
Education of mothers may improve child health. We investigated whether maternal health literacy, a rapidly modifiable factor related to mother's education, was associated with children's receipt of vaccines in two underserved Indian communities. Cross-sectional surveys in an urban and a rural site. We assessed health literacy using Indian child health promotion materials. The outcome was receipt of three doses of diphtheria-tetanus-pertussis (DTP3) vaccine. We used multivariate logistic regression to investigate the relationship between maternal health literacy and vaccination status independently in each site. For both sites, adjusted models considered maternal age, maternal and paternal education, child sex, birth order, household religion and wealth quintile. Rural analyses used multilevel models adjusted for service delivery characteristics. Urban analyses represented cluster characteristics through fixed effects. The rural analysis included 1170 women from 60 villages. The urban analysis included 670 women from nine slum clusters. In each site, crude and adjusted models revealed a positive association between maternal health literacy and DTP3. In the rural site, the adjusted OR was 1.57 (95% CI 1.11 to 2.21, p=0.010) for those with medium health literacy, and OR=1.30 (95% CI 0.89 to 1.91, p=0.172) for those with high health literacy. In the urban site, the adjusted OR was 1.10 (95% CI 0.65 to 1.88, p=0.705) for those with medium health literacy, and OR=2.06 (95% CI 1.06 to 3.99, p=0.032) for those with high health literacy. In these study settings, maternal health literacy is independently associated with child vaccination. Initiatives targeting health literacy could improve vaccination coverage. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Bridgett, David J.; Burt, Nicole M.; Laake, Lauren M.; Oddi, Kate B.
2013-01-01
There has been increasing interest in the direct and indirect effects of parental self-regulation on children’s outcomes. In the present investigation, the effects of maternal self-regulation, home chaos, and inter-parental relationship adjustment on broad and specific indicators of infant negative emotionality (NE) were examined. A sample of maternal caregivers and their 4-month-old infants (N = 85) from a rural community participated. Results demonstrated that better maternal self-regulation was associated with lower infant NE broadly, as well as with lower infant sadness and distress to limitations/frustration and better falling reactivity (i.e. emotion regulation), specifically. Maternal self-regulation also predicted less chaotic home environments and better maternal inter-parental relationship adjustment. Findings also supported the indirect effects of maternal self-regulation on broad and specific indicators of infant NE through home chaos and maternal relationship adjustment. Some differential effects were also identified. Elevated home chaos appeared to specifically affect infant frustration/distress to limitations whereas maternal relationship adjustment affected broad infant NE, as well as several specific indicators of infant NE: frustration/distress to limitations, sadness, and falling reactivity. In conjunction with other recent investigations that have reported the effects of maternal self-regulation on parenting, the findings in the present investigation suggest that parental self-regulation may influence children’s outcomes through several proximal environmental pathways. PMID:23748168
Bridgett, David J; Burt, Nicole M; Laake, Lauren M; Oddi, Kate B
2013-12-01
There has been increasing interest in the direct and indirect effects of parental self-regulation on children's outcomes. In the present investigation, the effects of maternal self-regulation, home chaos, and inter-parental relationship adjustment on broad and specific indicators of infant negative emotionality (NE) were examined. A sample of maternal caregivers and their 4-month-old infants (N = 85) from a rural community participated. Results demonstrated that better maternal self-regulation was associated with lower infant NE broadly, as well as with lower infant sadness and distress to limitations/frustration and better falling reactivity (i.e., emotion regulation), specifically. Maternal self-regulation also predicted less chaotic home environments and better maternal inter-parental relationship adjustment. Findings also supported the indirect effects of maternal self-regulation on broad and specific indicators of infant NE through home chaos and maternal relationship adjustment. Some differential effects were also identified. Elevated home chaos appeared to specifically affect infant frustration/distress to limitations whereas maternal relationship adjustment affected broad infant NE, as well as several specific indicators of infant NE: frustration/distress to limitations, sadness, and falling reactivity. In conjunction with other recent investigations that have reported the effects of maternal self-regulation on parenting, the findings in the present investigation suggest that parental self-regulation may influence children's outcomes through several proximal environmental pathways. Copyright © 2013 Elsevier Inc. All rights reserved.
26 CFR 1.472-1 - Last-in, first-out inventories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... may elect to have such method apply to the raw materials only (including those included in goods in... adjustments are confined to costs of the raw material in the inventory and the cost of the raw material in... that the opening inventory had 10 units of raw material, 10 units of goods in process, and 10 units of...
26 CFR 1.472-1 - Last-in, first-out inventories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... may elect to have such method apply to the raw materials only (including those included in goods in... adjustments are confined to costs of the raw material in the inventory and the cost of the raw material in... that the opening inventory had 10 units of raw material, 10 units of goods in process, and 10 units of...
26 CFR 1.472-1 - Last-in, first-out inventories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... may elect to have such method apply to the raw materials only (including those included in goods in... adjustments are confined to costs of the raw material in the inventory and the cost of the raw material in... that the opening inventory had 10 units of raw material, 10 units of goods in process, and 10 units of...
26 CFR 1.472-1 - Last-in, first-out inventories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... may elect to have such method apply to the raw materials only (including those included in goods in... adjustments are confined to costs of the raw material in the inventory and the cost of the raw material in... that the opening inventory had 10 units of raw material, 10 units of goods in process, and 10 units of...
Functional Characterization of a Novel Shape Memory Alloy
NASA Astrophysics Data System (ADS)
Collado, M.; Cabás, R.; San Juan, J.; López-Ferreño, I.
2014-07-01
A novel shape memory alloy (SMA) has been developed as an alternative to currently available alloys. This alloy, commercially known by its proprietary brand SMARQ, shows a higher working range of temperatures with respect to the SMA materials used until now in actuators, limited to environment temperatures below 90 °C. SMARQ is a high temperature SMA (HTSMA) based on a fully European material technology and production processes, which allows the manufacture of high quality products, with tuneable transformation temperatures up to 200 °C. Both, material and production processes have been evaluated for its use in space applications. A full characterization test campaign has been completed in order to obtain the material properties and check its suitability to be used as active material in space actuators. In order to perform the functional characterization of the material, it has been considered as the key element of a basic SMA actuator, consisting in the SMA wire and the mechanical and electrical interfaces. The functional tests presented in this work have been focused on the actuator behavior when heated by means of an electrical current. Alloy composition has been adjusted in order to match a transition temperature (As) of +145 °C, which satisfies the application requirements of operating temperatures in the range of -70 and +125 °C. Details of the tests and results of the characterization test campaign, focused in the material unique properties for their use in actuators, will be presented in this work. Some application examples in the field of space mechanisms and actuators, currently under development, will be summarized as part of this work, demonstrating the technology suitability as active material for space actuators.
Sequential and simultaneous SLAR block adjustment. [spline function analysis for mapping
NASA Technical Reports Server (NTRS)
Leberl, F.
1975-01-01
Two sequential methods of planimetric SLAR (Side Looking Airborne Radar) block adjustment, with and without splines, and three simultaneous methods based on the principles of least squares are evaluated. A limited experiment with simulated SLAR images indicates that sequential block formation with splines followed by external interpolative adjustment is superior to the simultaneous methods such as planimetric block adjustment with similarity transformations. The use of the sequential block formation is recommended, since it represents an inexpensive tool for satisfactory point determination from SLAR images.
McCafferty, D J; Pandraud, G; Gilles, J; Fabra-Puchol, M; Henry, P-Y
2017-12-28
Birds and mammals have evolved many thermal adaptations that are relevant to the bioinspired design of temperature control systems and energy management in buildings. Similar to many buildings, endothermic animals generate internal metabolic heat, are well insulated, regulate their temperature within set limits, modify microclimate and adjust thermal exchange with their environment. We review the major components of animal thermoregulation in endothermic birds and mammals that are pertinent to building engineering, in a world where climate is changing and reduction in energy use is needed. In animals, adjustment of insulation together with physiological and behavioural responses to changing environmental conditions fine-tune spatial and temporal regulation of body temperature, while also minimizing energy expenditure. These biological adaptations are characteristically flexible, allowing animals to alter their body temperatures to hourly, daily, or annual demands for energy. They exemplify how buildings could become more thermally reactive to meteorological fluctuations, capitalising on dynamic thermal materials and system properties. Based on this synthesis, we suggest that heat transfer modelling could be used to simulate these flexible biomimetic features and assess their success in reducing energy costs while maintaining thermal comfort for given building types.
Linear positioning laser calibration setup of CNC machine tools
NASA Astrophysics Data System (ADS)
Sui, Xiulin; Yang, Congjing
2002-10-01
The linear positioning laser calibration setup of CNC machine tools is capable of executing machine tool laser calibraiotn and backlash compensation. Using this setup, hole locations on CNC machien tools will be correct and machien tool geometry will be evaluated and adjusted. Machien tool laser calibration and backlash compensation is a simple and straightforward process. First the setup is to 'find' the stroke limits of the axis. Then the laser head is then brought into correct alignment. Second is to move the machine axis to the other extreme, the laser head is now aligned, using rotation and elevation adjustments. Finally the machine is moved to the start position and final alignment is verified. The stroke of the machine, and the machine compensation interval dictate the amount of data required for each axis. These factors determine the amount of time required for a through compensation of the linear positioning accuracy. The Laser Calibrator System monitors the material temperature and the air density; this takes into consideration machine thermal growth and laser beam frequency. This linear positioning laser calibration setup can be used on CNC machine tools, CNC lathes, horizontal centers and vertical machining centers.
Gerstenecker, Adam; Niccolai, Lindsay; Marson, Daniel; Triebel, Kristen L
2016-04-01
A number of measures have been developed to assess medical decision-making capacity (MDC) in adults. However, their clinical utility is limited by a lack of available normative data. In the current study, we introduce age-independent and age-adjusted normative data for a measure of MDC: the Capacity to Consent to Treatment Instrument. The sample consisted of 308 cognitively normal, community-dwelling adults ranging in age from 19 to 86 years. For age-adjusted norms, individual raw scores were first converted to age-corrected scaled scores based on position within a cumulative frequency distribution and then grouped according to empirically supported age ranges. For age-independent norms, the same method was utilized but without age-corrections being applied or participants being grouped into age ranges. This study has the potential to enhance MDC evaluations by allowing clinicians to compare a patient's performance on the Capacity to Consent to Treatment Instrument with that of adults regardless of age as well as to same age peers. Tables containing normative corrections are supplementary material available online at http://asm.sagepub.com/supplemental. © The Author(s) 2015.
Methods and apparatus for altering material using ion beams
Bloomquist, Douglas D.; Buchheit, Rudy; Greenly, John B.; McIntyre, Dale C.; Neau, Eugene L.; Stinnett, Regan W.
1996-01-01
A method and apparatus for treating material surfaces using a repetitively pulsed ion beam. In particular, a method of treating magnetic material surfaces in order to reduce surface defects, and produce amorphous fine grained magnetic material with properties that can be tailored by adjusting treatment parameters of a pulsed ion beam. In addition to a method of surface treating materials for wear and corrosion resistance using pulsed particle ion beams.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-11
... costs incurred for adjusting their facilities. The railroad companies must have a system for recording labor, materials, supplies, and equipment costs incurred when undertaking the necessary railroad work...: Developing and Recording Costs for Railroad Adjustments. OMB Control Number: 2125-0521. Background: Under 23...
Control method and system for use when growing thin-films on semiconductor-based materials
McKee, Rodney A.; Walker, Frederick J.
2001-01-01
A process and system for use during the growth of a thin film upon the surface of a substrate by exposing the substrate surface to vaporized material in a high vacuum (HV) facility involves the directing of an electron beam generally toward the surface of the substrate as the substrate is exposed to vaporized material so that electrons are diffracted from the substrate surface by the beam and the monitoring of the pattern of electrons diffracted from the substrate surface as vaporized material settles upon the substrate surface. When the monitored pattern achieves a condition indicative of the desired condition of the thin film being grown upon the substrate, the exposure of the substrate to the vaporized materials is shut off or otherwise adjusted. To facilitate the adjustment of the crystallographic orientation of the film relative to the electron beam, the system includes a mechanism for altering the orientation of the surface of the substrate relative to the electron beam.
Bernsmeier, Denis; Polte, Jörg; Ortel, Erik; Krahl, Thoralf; Kemnitz, Erhard; Kraehnert, Ralph
2014-11-26
Minimizing efficiency losses caused by unwanted light reflection at the interface between lenses, optical instruments and solar cells with the surrounding medium requires antireflective coatings with adequate refractive index and coating thickness. We describe a new type of antireflective coating material with easily and independently tailorable refractive index and coating thickness based on the deposition of colloidal MgF2 nanoparticles. The material synthesis employs micelles of amphiphilic block copolymers as structure directing agent to introduce controlled mesoporosity into MgF2 film. The coatings thickness can be easily adjusted by the applied coating conditions. The coatings refractive index is determined by the materials porosity, which is controlled by the amount of employed pore template. The refractive index can be precisely tuned between 1.23 and 1.11, i.e., in a range that is not accessible to nonporous inorganic materials. Hence, zero reflectance conditions can be established for a wide range of substrate materials.
Recovery of germanium-68 from irradiated targets
Phillips, Dennis R.; Jamriska, Sr., David J.; Hamilton, Virginia T.
1993-01-01
A process for selective separation of germanium-68 from proton irradiated molybdenum targets is provided and includes dissolving the molybdenum target in a hydrogen peroxide solution to form a first ion-containing solution, contacting the first ion-containing solution with a cationic resin whereby ions selected from the group consisting of molybdenum, niobium, technetium, selenium, vanadium, arsenic, germanium, zirconium and rubidium remain in a second ion-containing solution while ions selected from the group consisting of rubidium, zinc, beryllium, cobalt, iron, manganese, chromium, strontium, yttrium and zirconium are selectively adsorbed by the first resin, adjusting the pH of the second ion-containing solution to within a range of from about 0.7 to about 3.0, adjusting the soluble metal halide concentration in the second ion-containing solution to a level adapted for subsequent separation of germanium, contacting the pH-adjusted, soluble metal halide-containing second ion-containing solution with a dextran-based material whereby germanium ions are separated by the dextran-based material, and recovering the germanium from the dextran-based material, preferably by distillation.
Kołłątaj, Barbara; Gorczyca, Rafał; Kołłątaj, Witold; Jędrych, Marian; Sobieszczańska, Anna; Sobieszczański, Jarosław; Karwat, Irena Dorota
2015-01-01
The elimination of functional barriers resulting from disability through the provision of adequate orthopaedic and rehabilitation equipment, and homes adjusted for disability is the precondition for an efficient and independent functioning, and high quality of life of the disabled. The objective of the study was recognition of the needs of the disabled declared by them, and the degree of satisfaction with these needs. The study covered 478 disabled from the Lublin Region. The research instrument was the 'Questionnaire for the Disabled' designed by the authors. Considering the needs expressed by the respondents concerning the provision of orthopaedic and rehabilitation equipment and meeting these needs, four groups were distinguished: No Needs - 30.1%, Needs Partially Met - 22.4%, Needs Fully Met - 37.7%, Needs Not Met - 9.8%. The group Needs Not Met was characterized by younger age, in the group Needs Partially Met worse indicators of the state of health were noted, more frequent independent living, loneliness and low material standard. Considering the expressed needs for home adjustments adequate to disability and meeting these needs, three groups were distinguished: No Needs - 59.6%, Needs Not Met - 15.9%, and Needs Met - 24.7%. The group Needs Not Met more rarely covered respondents living in residential homes, compared to those living independently in rural or urban areas. The group Needs Met more rarely included rural inhabitants, while more frequently including the disabled who had a high material standard. Both the provision of orthopaedic equipment and adjustment of the home to disability are insufficient with respect to the needs. The meeting of these needs is significantly conditioned by high or very high material standard. The lack or incomplete satisfaction with the needs for rehabilitation equipment is associated with a relatively younger age, independent, single residence and low material standard. Living in an residential home means better adjustment of the living environment, and better provision with orthopaedic and rehabilitation equipment.
Photocathode device that replenishes photoemissive coating
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moody, Nathan A.; Lizon, David C.
2016-06-14
A photocathode device may replenish its photoemissive coating to replace coating material that desorbs/evaporates during photoemission. A linear actuator system may regulate the release of a replenishment material vapor, such as an alkali metal, from a chamber inside the photocathode device to a porous cathode substrate. The replenishment material deposits on the inner surface of a porous membrane and effuses through the membrane to the outer surface, where it replenishes the photoemissive coating. The rate of replenishment of the photoemissive coating may be adjusted using the linear actuator system to regulate performance of the photocathode device during photoemission. Alternatively, themore » linear actuator system may adjust a plasma discharge gap between a cartridge containing replenishment material and a metal grid. A potential is applied between the cartridge and the grid, resulting in ejection of metal ions from the cartridge that similarly replenish the photoemissive coating.« less
Momoli, F; Siemiatycki, J; McBride, M L; Parent, M-É; Richardson, L; Bedard, D; Platt, R; Vrijheid, M; Cardis, E; Krewski, D
2017-10-01
We undertook a re-analysis of the Canadian data from the 13-country case-control Interphone Study (2001-2004), in which researchers evaluated the associations of mobile phone use with the risks of brain, acoustic neuroma, and parotid gland tumors. In the main publication of the multinational Interphone Study, investigators concluded that biases and errors prevented a causal interpretation. We applied a probabilistic multiple-bias model to address possible biases simultaneously, using validation data from billing records and nonparticipant questionnaires as information on recall error and selective participation. In our modeling, we sought to adjust for these sources of uncertainty and to facilitate interpretation. For glioma, when comparing those in the highest quartile of use (>558 lifetime hours) to those who were not regular users, the odds ratio was 2.0 (95% confidence interval: 1.2, 3.4). After adjustment for selection and recall biases, the odds ratio was 2.2 (95% limits: 1.3, 4.1). There was little evidence of an increase in the risk of meningioma, acoustic neuroma, or parotid gland tumors in relation to mobile phone use. Adjustments for selection and recall biases did not materially affect interpretation in our results from Canadian data. © The Author(s) 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Ames, A.; Bruni, R.; Cotroneo, V.; Johnson-Wilke, R.; Kester, T.; Reid, P.; Romaine, S.; Tolier-McKinstry, S.; Wilke, R. H. T.
2015-09-01
Adjustable X-ray optics represent a potential enabling technology for simultaneously achieving large effective area and high angular resolution for future X-ray Astronomy missions. The adjustable optics employ a bimorph mirror composed of a thin (1.5 μm) film of piezoelectric material deposited on the back of a 0.4 mm thick conical mirror segment. The application of localized electric fields in the piezoelectric material, normal to the mirror surface, result in localized deformations in mirror shape. Thus, mirror fabrication and mounting induced figure errors can be corrected, without the need for a massive reaction structure. With this approach, though, film stresses in the piezoelectric layer, resulting from deposition, crystallization, and differences in coefficient of thermal expansion, can distort the mirror. The large relative thickness of the piezoelectric material compared to the glass means that even 100MPa stresses can result in significant distortions. We have examined compensating for the piezoelectric processing related distortions by the deposition of controlled stress chromium/iridium films on the front surface of the mirror. We describe our experiments with tuning the product of the chromium/iridium film stress and film thickness to balance that resulting from the piezoelectric layer. We also evaluated the repeatability of this deposition process, and the robustness of the iridium coating.
19 CFR 10.596 - Value of materials.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Salvador purchases material x from an unrelated seller in El Salvador for $100. Under the provisions of... payable for the goods when sold to the producer in El Salvador ($100), adjusted in accordance with the... Salvador by the seller (or by anyone else). So long as the producer acquired material x in El Salvador, it...
19 CFR 10.596 - Value of materials.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Salvador purchases material x from an unrelated seller in El Salvador for $100. Under the provisions of... payable for the goods when sold to the producer in El Salvador ($100), adjusted in accordance with the... Salvador by the seller (or by anyone else). So long as the producer acquired material x in El Salvador, it...
NASA Technical Reports Server (NTRS)
Kerley, James J. (Inventor); Eklund, Wayne D. (Inventor)
1992-01-01
A device for holding reading materials for use by readers without arm mobility is presented. The device is adapted to hold the reading materials in position for reading with the pages displayed to enable turning by use of a rubber tipped stick that is held in the mouth and has a pair of rectangular frames. The frames are for holding and positioning the reading materials opened in reading posture with the pages displayed at a substantially unobstructed sighting position for reading. The pair of rectangular frames are connected to one another by a hinge so the angle between the frames may be varied thereby varying the inclination of the reading material. A pair of bent spring mounted wires for holding opposing pages of the reading material open for reading without substantial visual interference of the pages is mounted to the base. The wires are also adjustable to the thickness of the reading material and have a variable friction adjustment. This enables the force of the wires against the pages to be varied and permits the reader to manipulate the pages with the stick.
39 CFR 3010.2 - Types of rate adjustments for market dominant products.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., authorized under 39 U.S.C. 3622(d)(1)(E), is based on exigent circumstances. (b) Upon the establishment of... adjustment, authorized under 39 U.S.C. 3622(d)(1)(D), is based on the statutory annual limitation. A Type 1-B rate adjustment, authorized under 39 U.S.C. 3622(d)(2)(C), is based on an exception to the annual...
Method for depositing layers of high quality semiconductor material
Guha, Subhendu; Yang, Chi C.
2001-08-14
Plasma deposition of substantially amorphous semiconductor materials is carried out under a set of deposition parameters which are selected so that the process operates near the amorphous/microcrystalline threshold. This threshold varies as a function of the thickness of the depositing semiconductor layer; and, deposition parameters, such as diluent gas concentrations, must be adjusted as a function of layer thickness. Also, this threshold varies as a function of the composition of the depositing layer, and in those instances where the layer composition is profiled throughout its thickness, deposition parameters must be adjusted accordingly so as to maintain the amorphous/microcrystalline threshold.
Adjusting Permittivity by Blending Varying Ratios of SWNTs
NASA Technical Reports Server (NTRS)
Tour, James M.; Stephenson, Jason J.; Higginbotham, Amanda
2012-01-01
A new composite material of singlewalled carbon nanotubes (SWNTs) displays radio frequency (0 to 1 GHz) permittivity properties that can be adjusted based upon the nanotube composition. When varying ratios of raw to functionalized SWNTs are blended into the silicone elastomer matrix at a total loading of 0.5 percent by weight, a target real permittivity value can be obtained between 70 and 3. This has particular use for designing materials for microwave lenses, microstrips, filters, resonators, high-strength/low-weight electromagnetic interference (EMI) shielding, antennas, waveguides, and low-loss magneto-dielectric products for applications like radome construction.
The Material Supply Adjustment Process in RAMF-SM, Step 2
2016-06-01
contain. The Risk Assessment and Mitigation Framework for Strategic Materials (RAMF-SM) is a suite of mathematical models and databases that has been...Risk Assessment and Mitigation Framework for Strategic Materials (RAMF-SM) is a suite of mathematical models and databases used to support the...and computes material shortfalls.1 Several mathematical models and dozens of databases, encompassing thousands of data items, support the
Plasticity of crassulacean acid metabolism at subtropical latitudes: a pineapple case study.
Rainha, Nuno; Medeiros, Violante P; Câmara, Mariana; Faustino, Hélder; Leite, João P; Barreto, Maria do Carmo; Cruz, Cristina; Pacheco, Carlos A; Ponte, Duarte; Bernardes da Silva, Anabela
2016-01-01
Plants with the crassulacean acid metabolism (CAM) express high-metabolic plasticity, to adjust to environmental stresses. This article hypothesizes that irradiance and nocturnal temperatures are the major limitations for CAM at higher latitudes such as the Azores (37°45'N). Circadian CAM expression in Ananas comosus L. Merr. (pineapple) was assessed by the diurnal pattern of leaf carbon fixation into l-malate at the solstices and equinoxes, and confirmed by determining maximal phosphoenolpyruvate carboxylase (PEPC) activity in plant material. Metabolic adjustments to environmental conditions were confirmed by gas exchange measurements, and integrated with environmental data to determine CAM's limiting factors: light and temperature. CAM plasticity was observed at the equinoxes, under similar photoperiods, but different environmental conditions. In spring, CAM expression was similar between vegetative and flowering plants, while in autumn, flowering (before anthesis) and fructifying (with fully developed fruit before ripening) plants accumulated more l-malate. Below 100 µmol m(-2) s(-1) , CAM phase I was extended, reducing CAM phase III during the day. Carbon fixation inhibition may occur by two major pathways: nocturnal temperature (<15°C) inhibiting PEPC activity and l-malate accumulation; and low irradiance influencing the interplay between CAM phase I and III, affecting carboxylation and decarboxylation. Both have important consequences for plant development in autumn and winter. Observations were confirmed by flowering time prediction using environmental data, emphasizing that CAM expression had a strong seasonal regulation due to a complex network response to light and temperature, allowing pineapple to survive in environments not suitable for high productivity. © 2015 Scandinavian Plant Physiology Society.
Ekemen, Zeynep; Ahmad, Zeeshan; Stride, Eleanor; Kaplan, David; Edirisinghe, Mohan
2013-05-13
Conventional fabrication techniques and structures employed in the design of silk fibroin (SF) based porous materials provide only limited control over pore size and require several processing stages. In this study, it is shown that, by utilizing electrohydrodynamic bubbling, not only can new hollow spherical structures of SF be formed in a single step by means of bubbles, but the resulting bubbles can serve as pore generators when dehydrated. The bubble characteristics can be controlled through simple adjustments to the processing parameters. Bubbles with diameters in the range of 240-1000 μm were fabricated in controlled fashion. FT-IR characterization confirmed that the rate of air infused during processing enhanced β-sheet packing in SF at higher flow rates. Dynamic mechanical analysis also demonstrated a correlation between air flow rate and film tensile strength. Results indicate that electrohydrodynamically generated SF and their composite bubbles can be employed as new tools to generate porous structures in a controlled manner with a range of potential applications in biocoatings and tissue engineering scaffolds.
Moore, Lynne; Turgeon, Alexis F; Sirois, Marie-Josée; Murat, Valérie; Lavoie, André
2011-09-01
Trauma center performance evaluations generally include adjustment for injury severity, age, and comorbidity. However, disparities across trauma centers may be due to other differences in source populations that are not accounted for, such as socioeconomic status (SES). We aimed to evaluate whether SES influences trauma center performance evaluations in an inclusive trauma system with universal access to health care. The study was based on data collected between 1999 and 2006 in a Canadian trauma system. Patient SES was quantified using an ecologic index of social and material deprivation. Performance evaluations were based on mortality adjusted using the Trauma Risk Adjustment Model. Agreement between performance results with and without additional adjustment for SES was evaluated with correlation coefficients. The study sample comprised a total of 71,784 patients from 48 trauma centers, including 3,828 deaths within 30 days (4.5%) and 5,549 deaths within 6 months (7.7%). The proportion of patients in the highest quintile of social and material deprivation varied from 3% to 43% and from 11% to 90% across hospitals, respectively. The correlation between performance results with or without adjustment for SES was almost perfect (r = 0.997; 95% CI 0.995-0.998) and the same hospital outliers were identified. We observed an important variation in SES across trauma centers but no change in risk-adjusted mortality estimates when SES was added to adjustment models. Results suggest that after adjustment for injury severity, age, comorbidity, and transfer status, disparities in SES across trauma center source populations do not influence trauma center performance evaluations in a system offering universal health coverage. Copyright © 2011 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
46 CFR 162.018-5 - Blow-down adjustment and popping tolerance.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Safety Relief Valves, Liquefied Compressed Gas § 162.018-5 Blow-down adjustment and popping tolerance. (a) Safety relief valves shall be so.... Safety relief valves shall be designed to open sharply and reach full lift and capacity at the maximum...
46 CFR 162.018-5 - Blow-down adjustment and popping tolerance.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Safety Relief Valves, Liquefied Compressed Gas § 162.018-5 Blow-down adjustment and popping tolerance. (a) Safety relief valves shall be so.... Safety relief valves shall be designed to open sharply and reach full lift and capacity at the maximum...
46 CFR 162.018-5 - Blow-down adjustment and popping tolerance.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Safety Relief Valves, Liquefied Compressed Gas § 162.018-5 Blow-down adjustment and popping tolerance. (a) Safety relief valves shall be so.... Safety relief valves shall be designed to open sharply and reach full lift and capacity at the maximum...
46 CFR 162.018-5 - Blow-down adjustment and popping tolerance.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Safety Relief Valves, Liquefied Compressed Gas § 162.018-5 Blow-down adjustment and popping tolerance. (a) Safety relief valves shall be so.... Safety relief valves shall be designed to open sharply and reach full lift and capacity at the maximum...
46 CFR 162.018-5 - Blow-down adjustment and popping tolerance.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Safety Relief Valves, Liquefied Compressed Gas § 162.018-5 Blow-down adjustment and popping tolerance. (a) Safety relief valves shall be so.... Safety relief valves shall be designed to open sharply and reach full lift and capacity at the maximum...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-21
... and Clauses (DFARS Case 2011-D048) AGENCY: Defense Acquisition Regulations System, Department of... Price Adjustment--Wage Rates or Material Adjustment--Wage Rates or Prices Controlled by a Foreign... Orders 12866 and 13563 Executive Orders (E.O.s) 12866 and 13563 direct agencies to assess all costs and...
39 CFR 3010.26 - Calculation of unused rate adjustment authority.
Code of Federal Regulations, 2011 CFR
2011-07-01
... authority for each class is equal to the difference between the maximum allowable percentage change in rates under the applicable rate limitation and the actual percentage change in rates for that class. (c) When... rate adjustment leading to its computation. ...
Predicting shrinkage and warpage in injection molding: Towards automatized mold design
NASA Astrophysics Data System (ADS)
Zwicke, Florian; Behr, Marek; Elgeti, Stefanie
2017-10-01
It is an inevitable part of any plastics molding process that the material undergoes some shrinkage during solidification. Mainly due to unavoidable inhomogeneities in the cooling process, the overall shrinkage cannot be assumed as homogeneous in all volumetric directions. The direct consequence is warpage. The accurate prediction of such shrinkage and warpage effects has been the subject of a considerable amount of research, but it is important to note that this behavior depends greatly on the type of material that is used as well as the process details. Without limiting ourselves to any specific properties of certain materials or process designs, we aim to develop a method for the automatized design of a mold cavity that will produce correctly shaped moldings after solidification. Essentially, this can be stated as a shape optimization problem, where the cavity shape is optimized to fulfill some objective function that measures defects in the molding shape. In order to be able to develop and evaluate such a method, we first require simulation methods for the diffierent steps involved in the injection molding process that can represent the phenomena responsible for shrinkage and warpage ina sufficiently accurate manner. As a starting point, we consider the solidification of purely amorphous materials. In this case, the material slowly transitions from fluid-like to solid-like behavior as it cools down. This behavior is modeled using adjusted viscoelastic material models. Once the material has passed a certain temperature threshold during cooling, any viscous effects are neglected and the behavior is assumed to be fully elastic. Non-linear elastic laws are used to predict shrinkage and warpage that occur after this point. We will present the current state of these simulation methods and show some first approaches towards optimizing the mold cavity shape based on these methods.
Comparability of clinical wear measurements by optical 3D laser scanning in two different centers.
Stober, Thomas; Heuschmid, Navina; Zellweger, Gaby; Rousson, Valentin; Rues, Stefan; Heintze, Siegward D
2014-05-01
The purpose of this study was to compare the use of different variables to measure the clinical wear of two denture tooth materials in two analysis centers. Twelve edentulous patients were provided with full dentures. Two different denture tooth materials (experimental material and control) were placed randomly in accordance with the split-mouth design. For wear measurements, impressions were made after an adjustment phase of 1-2 weeks and after 6, 12, 18, and 24 months. The occlusal wear of the posterior denture teeth of 11 subjects was assessed in two study centers by use of plaster replicas and 3D laser-scanning methods. In both centers sequential scans of the occlusal surfaces were digitized and superimposed. Wear was described by use of four different variables. Statistical analysis was performed after log-transformation of the wear data by use of the Pearson and Lin correlation and by use of a mixed linear model. Mean occlusal vertical wear of the denture teeth after 24 months was between 120μm and 212μm, depending on wear variable and material. For three of the four variables, wear of the experimental material was statistically significantly less than that of the control. Comparison of the two study centers, however, revealed correlation of the wear variables was only moderate whereas strong correlation was observed among the different wear variables evaluated by each center. Moderate correlation was observed for clinical wear measurements by optical 3D laser scanning in two different study centers. For the two denture tooth materials, wear measurements limited to the attrition zones led to the same qualitative assessment. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Keysor, Julie J; Jette, Alan M; LaValley, Michael P; Lewis, Cora E; Torner, James C; Nevitt, Michael C; Felson, Dave T
2010-04-01
There is limited evidence supporting the hypothesized environment-disability link. The objectives of this study were to (a) identify the prevalence of community mobility barriers and transportation facilitators and (b) examine whether barriers and facilitators were associated with disability among older adults with functional limitations. Four hundred and thirty-five participants aged 65+ years old with functional limitations were recruited from the Multicenter Osteoarthritis Study, a prospective study of community-dwelling adults with or at risk of developing symptomatic knee osteoarthritis. Presence of community barriers and facilitators was ascertained by the Home and Community Environment survey. Two domains of disability, (a) daily activity limitation (DAL) and (b) daily activity frequency (DAF), were assessed with the Late-Life Disability Instrument. Covariates included age, gender, education, race, comorbidity, body mass index, knee pain, and functional limitation. Multivariable logistic regression was used to examine adjusted associations of community factors with presence of DAL and DAF. Approximately one third of the participants lived in a community with high mobility barriers and low transportation facilitators. High mobility barriers was associated with greater odds of DAL (odds ratio [OR] = 2.0, 95% confidence interval [CI] 1.2-3.1) after adjusting for covariates, and high transportation facilitators was associated with lower odds of DAL (OR = 0.5, 95% CI 0.3-0.8) but not with DAF in adjusted models. People with functional limitations who live in communities that were more restrictive felt more limited in doing daily activities but did not perform these daily activities any less frequently.
ERIC Educational Resources Information Center
Minnesota State Department of Education, 2004
2004-01-01
Minnesota Statutes 2003, Section 127A.51, reads as follows: Section 127A.51 Statewide average revenue. By October 1 of each year the commissioner must estimate the statewide average adjusted general revenue per adjusted marginal cost pupil unit and the disparity in adjusted general revenue among pupils and districts by computing the ratio of the…
2012-01-01
Background Although it is known both patients’ and partners’ reactions to a prostate cancer diagnosis include fear, uncertainty, anxiety and depression with patients’ partners’ reactions mutually determining how they cope with and adjust to the illness, few psychosocial interventions target couples. Those that are available tend to be led by highly trained professionals, limiting their accessibility and long-term sustainability. In addition, it is recognised that patients who might benefit from conventional face-to-face psychosocial interventions do not access these, either by preference or because of geographical or mobility barriers. Self-directed interventions can overcome some of these limitations and have been shown to contribute to patient well-being. This study will examine the feasibility of a self-directed, coping skills intervention for couples affected by cancer, called Coping-Together, and begin to explore its potential impact on couples’ illness adjustment. The pilot version of Coping-Together includes a series of four booklets, a DVD, and a relaxation audio CD. Methods/design In this double-blind, two-group, parallel, randomized controlled trial, 70 couples will be recruited within 4 months of a prostate cancer diagnosis through urology private practices and randomized to: 1) Coping-Together or 2) a minimal ethical care condition. Minimal ethical care condition couples will be mailed information booklets available at the Cancer Council New South Wales and a brochure for the Cancer Council Helpline. The primary outcome (anxiety) and additional secondary outcomes (distress, depression, dyadic adjustment, quality of life, illness or caregiving appraisal, self-efficacy, and dyadic and individual coping) will be assessed at baseline (before receiving study material) and 2 months post-baseline. Intention-to-treat and per protocol analysis will be conducted. Discussion As partners’ distress rates exceed not only population norms, but also those reported by patients themselves, it is imperative that coping skills interventions target the couple as a unit and enhance both partners’ ability to overcome cancer challenges. This pilot study will examine the feasibility and potential efficacy of Coping-Together in optimising couples’ illness adjustment. This is one of the first feasibility studies to test this innovative coping intervention, which in turn will contribute to the larger literature advocating for psychosocial care of couples affected by prostate cancer. Trial registration Australian New Zealand Clinical Trials Registry ACTRN12611000438954 PMID:23013404
Absorbable Suture as an Apical Matrix in Single Visit Apexification with Mineral Trioxide Aggregate.
Goyal, Ayush; Nikhil, Vineeta; Jha, Padmanabh
2016-01-01
Several procedures have been recommended to induce the root end barrier formation in teeth with open apices. Conventional treatment for such cases will require many appointments with an average duration of 12.9 months. During this period, the root canal is susceptible to reinfection from around the provisional restoration, which may promote apical periodontitis and arrest of apical repair. Mineral trioxide aggregate (MTA) has been successfully used for one visit apexification wherein the root canal can be obturated within 24 hours after placement of MTA. Using a matrix prior to the placement of MTA avoids its extrusion, reduces leakage in the sealing material, and allows favorable response of the periapical tissues. This report presents a case of apexification where an absorbable suture was used as an apical matrix. Use of an absorbable suture circumvents all the problems associated with other conventional materials. Conclusion . Placement of the matrix made from the suture material is predictable and is easily positioned at the apex and the length can be adjusted as required. 10-month follow-up of the case shows resorbed matrix and bone healing in the periapical region. The patient was asymptomatic during the whole follow-up period and tooth exhibited mobility within physiologic limits and was functioning normally.
Buhr, T L; Young, A A; Minter, Z A; Wells, C M; McPherson, D C; Hooban, C L; Johnson, C A; Prokop, E J; Crigler, J R
2012-11-01
To develop test methods and evaluate the survival of Bacillus anthracis ∆Sterne and Bacillus thuringiensis Al Hakam spores after exposure to hot, humid air. Spores (>7 logs) of both strains were dried on six different test materials. Response surface methodology was employed to identify the limits of spore survival at optimal test combinations of temperature (60, 68, 77°C), relative humidity (60, 75, 90%) and time (1, 4, 7 days). No spores survived the harshest test run (77°C, 90% r.h., 7 days), while > 6·5 logs of spores survived the mildest test run (60°C, 60% r.h., 1 day). Spores of both strains inoculated on nylon webbing and polypropylene had greater survival rates at 68°C, 75% r.h., 4 days than spores on other materials. Electron microscopy showed no obvious physical damage to spores using hot, humid air, which contrasted with pH-adjusted bleach decontamination. Test methods were developed to show that hot, humid air effectively inactivates B. anthracis ∆Sterne and B. thuringiensis Al Hakam spores with similar kinetics. Hot, humid air is a potential alternative to conventional chemical decontamination. © 2012 The Authors Journal of Applied Microbiology © 2012 The Society for Applied Microbiology.
Wood, Henry M; Belvedere, Ornella; Conway, Caroline; Daly, Catherine; Chalkley, Rebecca; Bickerdike, Melissa; McKinley, Claire; Egan, Phil; Ross, Lisa; Hayward, Bruce; Morgan, Joanne; Davidson, Leslie; MacLennan, Ken; Ong, Thian K; Papagiannopoulos, Kostas; Cook, Ian; Adams, David J; Taylor, Graham R; Rabbitts, Pamela
2010-08-01
The use of next-generation sequencing technologies to produce genomic copy number data has recently been described. Most approaches, however, reply on optimal starting DNA, and are therefore unsuitable for the analysis of formalin-fixed paraffin-embedded (FFPE) samples, which largely precludes the analysis of many tumour series. We have sought to challenge the limits of this technique with regards to quality and quantity of starting material and the depth of sequencing required. We confirm that the technique can be used to interrogate DNA from cell lines, fresh frozen material and FFPE samples to assess copy number variation. We show that as little as 5 ng of DNA is needed to generate a copy number karyogram, and follow this up with data from a series of FFPE biopsies and surgical samples. We have used various levels of sample multiplexing to demonstrate the adjustable resolution of the methodology, depending on the number of samples and available resources. We also demonstrate reproducibility by use of replicate samples and comparison with microarray-based comparative genomic hybridization (aCGH) and digital PCR. This technique can be valuable in both the analysis of routine diagnostic samples and in examining large repositories of fixed archival material.
Method for making mirrored surfaces comprising superconducting material
Early, J.T.; Hargrove, R.S.
1989-12-12
Superconducting mirror surfaces are provided by forming a mirror surface from a material which is superconductive at a temperature above about 40 K and adjusting the temperature of the surface to that temperature at which the material is superconducting. The mirror surfaces are essentially perfect reflectors for electromagnetic radiation with photon energy less than the superconducting band gap.
Novel fluorescence adjustable photonic crystal materials
NASA Astrophysics Data System (ADS)
Zhu, Cheng; Liu, Xiaoxia; Ni, Yaru; Fang, Jiaojiao; Fang, Liang; Lu, Chunhua; Xu, Zhongzi
2017-11-01
Novel photonic crystal materials (PCMs) with adjustable fluorescence were fabricated by distributing organic fluorescent powders of Yb0.2Er0.4Tm0.4(TTA)3Phen into the opal structures of self-assembled silica photonic crystals (PCs). Via removing the silica solution in a constant speed, PCs with controllable thicknesses and different periodic sizes were obtained on glass slides. Yb0.2Er0.4Tm0.4(TTA)3Phen powders were subsequently distributed into the opal structures. The structures and optical properties of the prepared PCMs were investigated. Finite-difference-time-domain (FDTD) calculation was used to further analyze the electric field distributions in PCs with different periodic sizes while the relation between periodic sizes and fluorescent spectra of PCMs was discussed. The results showed that the emission color of the PCMs under irradiation of 980 nm laser can be easily adjusted from green to blue by increasing the periodic size from 250 to 450 nm.
Fatigue life analysis of a turboprop reduction gearbox
NASA Technical Reports Server (NTRS)
Lewicki, D. G.; Black, J. D.; Savage, M.; Coy, J. J.
1985-01-01
A fatigue life analysis of the Allison T56/501 turboprop reduction gearbox was developed. The life and reliability of the gearbox was based on the lives and reliabilities of the main power train bearings and gears. The bearing and gear lives were determined using the Lundberg-Palmgren theory and a mission profile. The five planet bearing set had the shortest calculated life among the various gearbox components, which agreed with field experience where the planet bearing had the greatest incidences of failure. The analytical predictions of relative lives among the various bearings were in reasonable agreement with field experience. The predicted gearbox life was in excellent agreement with field data when the material life adjustment factors alone were used. The gearbox had a lower predicted life in comparison with field data when no life adjustment factors were used or when lubrication life adjustment factors were used either alone or in combination with the material factors.
Fatigue life analysis of a turboprop reduction gearbox
NASA Technical Reports Server (NTRS)
Lewicki, D. G.; Coy, J. J.; Black, J. D.; Savage, M.
1986-01-01
A fatigue life analysis of the Allison T56/501 turboprop reduction gearbox was developed. The life and reliability of the gearbox was based on the lives and reliabilities of the main power train bearings and gears. The bearing and gear lives were determined using the Lundberg-Palmgren theory and a mission profile. The five planet bearing set had the shortest calculated life among the various gearbox components, which agreed with field experience where the planet bearing had the greatest incidences of failure. The analytical predictions of relative lives among the various bearings were in reasonable agreement with field experience. The predicted gearbox life was in excellent agreement with field data when the material life adjustment factors alone were used. The gearbox had a lower predicted life in comparison with field data when no life adjustment factors were used or when lubrication life adjustment factors were used either alone or in combination with the material factors.
European birds adjust their flight initiation distance to road speed limits.
Legagneux, Pierre; Ducatez, Simon
2013-10-23
Behavioural responses can help species persist in habitats modified by humans. Roads and traffic greatly affect animals' mortality not only through habitat structure modifications but also through direct mortality owing to collisions. Although species are known to differ in their sensitivity to the risk of collision, whether individuals can change their behaviour in response to this is still unknown. Here, we tested whether common European birds changed their flight initiation distances (FIDs) in response to vehicles according to road speed limit (a known factor affecting killing rates on roads) and vehicle speed. We found that FID increased with speed limit, although vehicle speed had no effect. This suggests that birds adjust their flight distance to speed limit, which may reduce collision risks and decrease mortality maximizing the time allocated to foraging behaviours. Mobility and territory size are likely to affect an individuals' ability to respond adaptively to local speed limits.
2007-12-01
therefore the resistance to thermal shock of this material. Thus, dopants such as La20 3 are to be avoided and alternative means to decrease the grain...of the furnace. Ceramic laser materials also have other potential advantages. The dopant concentration of the starting material can be adjusted so that...measurements on the polaron conductor (nickel cobalt spinel oxide) indicated that this material can support high current flows in oxygen environments at a few
Bernard, Thomas E; Iheanacho, Ivory
2015-01-01
Ambient temperature and relative humidity are readily ava-ilable and thus tempting metrics for heat stress assessment. Two methods of using air temperature and relative humidity to create an index are Heat Index and Adjusted Temperature. The purposes of this article are: (1) to examine how well Heat Index and Adjusted Temperature estimated the wet bulb globe temperature (WBGT) index, and (2) to suggest how Heat Index and Adjusted Temperature can be used to screen for heat stress level. Psychrometric relationships were used to estimate values of actual WBGT for conditions of air temperature, relative humidity, and radiant heat at an air speed of 0.5 m/s. A relationship between Heat Index [°F] and WBGT [°C] was described by WBGT = -0.0034 HI(2) + 0.96 HI - 34. At lower Heat Index values, the equation estimated WBGTs that were ± 2 °C-WBGT around the actual value, and to about ± 0.5 °C-WBGT for Heat Index values > 100 °F. A relationship between Adjusted Temperature [°F] and WBGT [°C] was described by WBGT = 0.45 Tadj - 16. The actual WBGT was between 1 °C-WBGT below the estimated value and 1.4 °C-WBGT above. That is, there was a slight bias toward overestimating WBGT from Adjusted Temperature. Heat stress screening tables were constructed for metabolic rates of 180, 300, and 450 W. The screening decisions were divided into four categories: (1) < alert limit, (2) < exposure limit, (3) hourly time-weighted averages (TWAs) of work and recovery, and (4) a caution zone for an exposure > exposure limit at rest. The authors do not recommend using Heat Index or Adjusted Temperature instead of WBGT, but they may be used to screen for circumstances when a more detailed analysis using WBGT is appropriate. A particular weakness is accounting for radiant heat; and neither air speed nor clothing was considered.
48 CFR 16.203-2 - Application.
Code of Federal Regulations, 2010 CFR
2010-10-01
... contract with economic price adjustment may be used when (i) there is serious doubt concerning the stability of market or labor conditions that will exist during an extended period of contract performance... limited to contingencies beyond the contractor's control. For use of economic price adjustment in sealed...
75 FR 30730 - Atlantic Highly Migratory Species; Atlantic Bluefin Tuna Fisheries
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-02
...-XW54 Atlantic Highly Migratory Species; Atlantic Bluefin Tuna Fisheries AGENCY: National Marine... Atlantic tunas General category daily Atlantic bluefin tuna (BFT) retention limit should be adjusted for... criteria regarding inseason adjustments. This action applies to Atlantic tunas General category permitted...
Dang, T. C.; Fujii, M.; Rose, A. L.; Bligh, M.
2012-01-01
A continuous culturing system (chemostat) made of metal-free materials was successfully developed and used to maintain Fe-limited cultures of Microcystis aeruginosa PCC7806 at nanomolar iron (Fe) concentrations (20 to 50 nM total Fe). EDTA was used to maintain Fe in solution, with bioavailable Fe controlled by absorption of light by the ferric EDTA complex and resultant reduction of Fe(III) to Fe(II). A kinetic model describing Fe transformations and biological uptake was applied to determine the biologically available form of Fe (i.e., unchelated ferrous iron) that is produced by photoreductive dissociation of the ferric EDTA complex. Prediction by chemostat theory modified to account for the light-mediated formation of bioavailable Fe rather than total Fe was in good agreement with growth characteristics of M. aeruginosa under Fe limitation. The cellular Fe quota increased with increasing dilution rates in a manner consistent with the Droop theory. Short-term Fe uptake assays using cells maintained at steady state indicated that M. aeruginosa cells vary their maximum Fe uptake rate (ρmax) depending on the degree of Fe stress. The rate of Fe uptake was lower for cells grown under conditions of lower Fe availability (i.e., lower dilution rate), suggesting that cells in the continuous cultures adjusted to Fe limitation by decreasing ρmax while maintaining a constant affinity for Fe. PMID:22210212
Tradeoffs in the Design of Health Plan Payment Systems: Fit, Power and Balance
Geruso, Michael; McGuire, Thomas G.
2016-01-01
In many markets, including the new U.S. Marketplaces, health insurance plans are paid by risk-adjusted capitation, sometimes combined with reinsurance and other payment mechanisms. This paper proposes a framework for evaluating the de facto insurer incentives embedded in these complex payment systems. We discuss fit, power and balance, each of which addresses a distinct market failure in health insurance. We implement empirical metrics of fit, power, and balance in a study of Marketplace payment systems. Using data similar to that used to develop the Marketplace risk adjustment scheme, we quantify tradeoffs among the three classes of incentives. We show that an essential tradeoff arises between the goals of limiting costs and limiting cream skimming because risk adjustment, which is aimed at discouraging cream-skimming, weakens cost control incentives in practice. A simple reinsurance system scores better on our measures of fit, power and balance than the risk adjustment scheme in use in the Marketplaces. PMID:26922122
Tradeoffs in the design of health plan payment systems: Fit, power and balance.
Geruso, Michael; McGuire, Thomas G
2016-05-01
In many markets, including the new U.S. Marketplaces, health insurance plans are paid by risk-adjusted capitation, sometimes combined with reinsurance and other payment mechanisms. This paper proposes a framework for evaluating the de facto insurer incentives embedded in these complex payment systems. We discuss fit, power and balance, each of which addresses a distinct market failure in health insurance. We implement empirical metrics of fit, power, and balance in a study of Marketplace payment systems. Using data similar to that used to develop the Marketplace risk adjustment scheme, we quantify tradeoffs among the three classes of incentives. We show that an essential tradeoff arises between the goals of limiting costs and limiting cream skimming because risk adjustment, which is aimed at discouraging cream-skimming, weakens cost control incentives in practice. A simple reinsurance system scores better on our measures of fit, power and balance than the risk adjustment scheme in use in the Marketplaces. Copyright © 2016 Elsevier B.V. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-21
...NMFS hereby implements measures approved in Amendment 15 to the Scallop FMP (Amendment 15), which was developed by the New England Fishery Management Council (Council). Amendment 15 was developed primarily to implement annual catch limits (ACLs) and accountability measures (AMs) to bring the Scallop FMP into compliance with requirements of the MSA as reauthorized in 2007. Amendment 15 includes additional measures recommended by the Council, including: A revision of the overfishing definition (OFD); modification of the essential fish habitat (EFH) closed areas under the Scallop FMP; adjustments to measures for the Limited Access General Category (LAGC) individual fishing quota (IFQ) fishery; adjustments to the scallop research set- aside (RSA) program; and additions to the list of measures that can be adjusted by framework adjustments. NMFS has disapproved a provision that would have allocated additional scallop catch to the LAGC fleet because it was not consistent with National Standard 1 and the ACL requirement of the MSA.
Health Literacy and Communication Quality in Health Care Organizations
Wynia, Matthew K.; Osborn, Chandra Y.
2011-01-01
The relationship between limited health literacy and poor health may be due to poor communication quality within health care delivery organizations. We explored the relationship between health literacy status and receiving patient-centered communication in clinics and hospitals serving communication-vulnerable patient populations. Thirteen health care organizations nationwide distributed a survey to 5,929 patients. All patients completed seven items assessing patient-centered communication. One third also completed three items assessing health literacy. The majority of patients had self-reported health literacy challenges, reporting problems learning about their medical condition because of difficulty understanding written information (53%), a lack of confidence in completing medical forms by themselves (61%), and needing someone to help them read hospital/clinic materials (57%). Logistic regression models showed that, after adjustment for patient demographic characteristics and health care organization type, patients with limited health literacy were 28–79% less likely than those with adequate health literacy to report their health care organization “always” provides patient-centered communication across seven communication items. Using a scaled composite of these items, limited health literacy remained associated with lower reported communication quality. These results suggest that improving communication quality in health care organizations might help to address the challenges facing patients with limited health literacy. They also highlight that efforts to address the needs of patients with limited health literacy should be sensitive to the range of communication challenges confronting these patients and their caregivers. PMID:20845197
Parallel processing of embossing dies with ultrafast lasers
NASA Astrophysics Data System (ADS)
Jarczynski, Manfred; Mitra, Thomas; Brüning, Stephan; Du, Keming; Jenke, Gerald
2018-02-01
Functionalization of surfaces equips products and components with new features like hydrophilic behavior, adjustable gloss level, light management properties, etc. Small feature sizes demand diffraction-limited spots and adapted fluence for different materials. Through the availability of high power fast repeating ultrashort pulsed lasers and efficient optical processing heads delivering diffraction-limited small spot size of around 10μm it is feasible to achieve fluences higher than an adequate patterning requires. Hence, parallel processing is becoming of interest to increase the throughput and allow mass production of micro machined surfaces. The first step on the roadmap of parallel processing for cylinder embossing dies was realized with an eight- spot processing head based on ns-fiber laser with passive optical beam splitting, individual spot switching by acousto optical modulation and an advanced imaging. Patterning of cylindrical embossing dies shows a high efficiency of nearby 80%, diffraction-limited and equally spaced spots with pitches down to 25μm achieved by a compression using cascaded prism arrays. Due to the nanoseconds laser pulses the ablation shows the typical surrounding material deposition of a hot process. In the next step the processing head was adapted to a picosecond-laser source and the 500W fiber laser was replaced by an ultrashort pulsed laser with 300W, 12ps and a repetition frequency of up to 6MHz. This paper presents details about the processing head design and the analysis of ablation rates and patterns on steel, copper and brass dies. Furthermore, it gives an outlook on scaling the parallel processing head from eight to 16 individually switched beamlets to increase processing throughput and optimized utilization of the available ultrashort pulsed laser energy.
Lim, Kah Heng Alexander; Loo, Zhou Yaw; Goldie, Stephen J; Adams, Justin W; McMenamin, Paul G
2016-05-06
Three-dimensional (3D) printing is an emerging technology capable of readily producing accurate anatomical models, however, evidence for the use of 3D prints in medical education remains limited. A study was performed to assess their effectiveness against cadaveric materials for learning external cardiac anatomy. A double blind randomized controlled trial was undertaken on undergraduate medical students without prior formal cardiac anatomy teaching. Following a pre-test examining baseline external cardiac anatomy knowledge, participants were randomly assigned to three groups who underwent self-directed learning sessions using either cadaveric materials, 3D prints, or a combination of cadaveric materials/3D prints (combined materials). Participants were then subjected to a post-test written by a third party. Fifty-two participants completed the trial; 18 using cadaveric materials, 16 using 3D models, and 18 using combined materials. Age and time since completion of high school were equally distributed between groups. Pre-test scores were not significantly different (P = 0.231), however, post-test scores were significantly higher for 3D prints group compared to the cadaveric materials or combined materials groups (mean of 60.83% vs. 44.81% and 44.62%, P = 0.010, adjusted P = 0.012). A significant improvement in test scores was detected for the 3D prints group (P = 0.003) but not for the other two groups. The finding of this pilot study suggests that use of 3D prints do not disadvantage students relative to cadaveric materials; maximally, results suggest that 3D may confer certain benefits to anatomy learning and supports their use and ongoing evaluation as supplements to cadaver-based curriculums. Anat Sci Educ 9: 213-221. © 2015 American Association of Anatomists. © 2015 American Association of Anatomists.
42 CFR 495.212 - Limitation on review.
Code of Federal Regulations, 2013 CFR
2013-10-01
... PROGRAM Requirements Specific to Medicare Advantage (MA) Organizations § 495.212 Limitation on review. (a... methodology and standards for determining payment amounts and payment adjustments under the MA EHR EP... related to the fixed schedule for application of limitation on incentive payments for all qualifying MA...
42 CFR 495.212 - Limitation on review.
Code of Federal Regulations, 2011 CFR
2011-10-01
... PROGRAM Requirements Specific to Medicare Advantage (MA) Organizations § 495.212 Limitation on review. (a... methodology and standards for determining payment amounts and payment adjustments under the MA EHR EP... related to the fixed schedule for application of limitation on incentive payments for all qualifying MA...
42 CFR 495.212 - Limitation on review.
Code of Federal Regulations, 2012 CFR
2012-10-01
... PROGRAM Requirements Specific to Medicare Advantage (MA) Organizations § 495.212 Limitation on review. (a... methodology and standards for determining payment amounts and payment adjustments under the MA EHR EP... related to the fixed schedule for application of limitation on incentive payments for all qualifying MA...
42 CFR 495.212 - Limitation on review.
Code of Federal Regulations, 2010 CFR
2010-10-01
... PROGRAM Requirements Specific to Medicare Advantage (MA) Organizations § 495.212 Limitation on review. (a... methodology and standards for determining payment amounts and payment adjustments under the MA EHR EP... related to the fixed schedule for application of limitation on incentive payments for all qualifying MA...
42 CFR 495.212 - Limitation on review.
Code of Federal Regulations, 2014 CFR
2014-10-01
... PROGRAM Requirements Specific to Medicare Advantage (MA) Organizations § 495.212 Limitation on review. (a... methodology and standards for determining payment amounts and payment adjustments under the MA EHR EP... related to the fixed schedule for application of limitation on incentive payments for all qualifying MA...
A Simple Laser Teaching Aid for Transverse Mode Structure Demonstration
ERIC Educational Resources Information Center
Ren, Cheng; Zhang, Shulian
2009-01-01
A teaching aid for demonstrating the transverse mode structure in lasers is described. A novel device called "multi-dimension adjustable combined cat-eye reflector" has been constructed from easily available materials to form a He-Ne laser resonator. By finely adjusting the cat-eye, the boundary conditions of the laser cavity can be altered, which…
Tusting, Lucy S; Bottomley, Christian; Gibson, Harry; Kleinschmidt, Immo; Tatem, Andrew J; Lindsay, Steve W; Gething, Peter W
2017-02-01
Improvements to housing may contribute to malaria control and elimination by reducing house entry by malaria vectors and thus exposure to biting. We tested the hypothesis that the odds of malaria infection are lower in modern, improved housing compared to traditional housing in sub-Saharan Africa (SSA). We analysed 15 Demographic and Health Surveys (DHS) and 14 Malaria Indicator Surveys (MIS) conducted in 21 countries in SSA between 2008 and 2015 that measured malaria infection by microscopy or rapid diagnostic test (RDT). DHS/MIS surveys record whether houses are built with finished materials (e.g., metal) or rudimentary materials (e.g., thatch). This information was used to develop a binary housing quality variable where houses built using finished wall, roof, and floor materials were classified as "modern", and all other houses were classified as "traditional". Conditional logistic regression was used to determine the association between housing quality and prevalence of malaria infection in children aged 0-5 y, adjusting for age, gender, insecticide-treated net (ITN) use, indoor residual spraying, household wealth, and geographic cluster. Individual survey odds ratios (ORs) were combined to determine a summary OR using a random effects meta-analysis. Of 284,532 total children surveyed, 139,318 were tested for malaria infection using microscopy (n = 131,652) or RDT (n = 138,540). Within individual surveys, malaria prevalence measured by microscopy ranged from 0.4% (Madagascar 2011) to 45.5% (Burkina Faso 2010) among children living in modern houses and from 0.4% (The Gambia 2013) to 70.6% (Burkina Faso 2010) in traditional houses, and malaria prevalence measured by RDT ranged from 0.3% (Senegal 2013-2014) to 61.2% (Burkina Faso 2010) in modern houses and from 1.5% (The Gambia 2013) to 79.8% (Burkina Faso 2010) in traditional houses. Across all surveys, modern housing was associated with a 9% to 14% reduction in the odds of malaria infection (microscopy: adjusted OR 0.91, 95% CI 0.85-0.97, p = 0.003; RDT: adjusted OR 0.86, 95% CI 0.80-0.92, p < 0.001). This association was consistent regardless of ITN usage. As a comparison, the odds of malaria infection were 15% to 16% lower among ITN users versus non-users (microscopy: adjusted OR 0.84, 95% CI 0.79-0.90, p < 0.001; RDT: adjusted OR 0.85, 95% CI 0.80-0.90, p < 0.001). The main limitation of this study is that residual confounding by household wealth of the observed association between housing quality and malaria prevalence is possible, since the wealth index may not have fully captured differences in socioeconomic position; however, the use of multiple national surveys offers the advantage of a large sample size and the elimination of many biases typically associated with pooling observational data. Housing quality is an important risk factor for malaria infection across the spectrum of malaria endemicity in SSA, with a strength of association between housing quality and malaria similar to that observed between ITN use and malaria. Improved housing should be considered a promising intervention for malaria control and elimination and long-term prevention of reintroduction.
Verma, Santosh K; Chang, Wen Ruey; Courtney, Theodore K; Lombardi, David A; Huang, Yueng-Hsiang; Brennan, Melanye J; Mittleman, Murray A; Ware, James H; Perry, Melissa J
2011-04-01
Slips and falls are a leading cause of injury at work. Few studies, however, have systematically examined risk factors of slipping outside the laboratory environment. This study examined the association between floor surface characteristics, slip-resistant shoes, floor cleaning frequency and the risk of slipping in limited-service restaurant workers. 475 workers from 36 limited-service restaurants from three major chains in six states in the USA were recruited to participate in a prospective cohort study of workplace slipping. Kitchen floor surface roughness and coefficient of friction (COF) were measured in eight working areas and then averaged within each restaurant. The use of slip-resistant shoes was determined by examining the participant's shoes and noting the presence of a 'slip-resistant' marking on the sole. Restaurant managers reported the frequency of daily kitchen floor cleaning. Participants reported their slip experience and work hours weekly for up to 12 weeks. The survey materials were made available in three languages: English, Spanish and Portuguese. The associations between rate of slipping and risk factors were assessed using a multivariable negative binomial generalised estimating equation model. The mean of individual slipping rate varied among the restaurants from 0.02 to 2.49 slips per 40 work hours. After adjusting for age, gender, BMI, education, primary language, job tenure and restaurant chain, the use of slip-resistant shoes was associated with a 54% reduction in the reported rate of slipping (95% CI 37% to 64%), and the rate of slipping decreased by 21% (95% CI 5% to 34%) for each 0.1 increase in the mean kitchen COF. Increasing floor cleaning frequency was significantly associated with a decreasing rate of slipping when considered in isolation but not after statistical adjustment for other factors. These results provide support for the use of slip-resistant shoes and measures to increase COF as preventive interventions to reduce slips, falls and injuries.
Fluid-filled bomb-disrupting apparatus and method
Cherry, Christopher R.
2001-01-01
An apparatus and method for disarming improvised bombs are disclosed. The apparatus comprises a fluid-filled bottle or container made of plastic or another soft material which contains a fixed or adjustable, preferably sheet explosive. The charge is fired centrally at its apex and can be adjusted to propel a fluid projectile that is broad or narrow, depending upon how it is set up. In one embodiment, the sheet explosive is adjustable so as to correlate the performance of the fluid projectile to the disarming needs for the improvised explosive device (IED). Common materials such as plastic water bottles or larger containers can be used, with the sheet explosive or other explosive material configured in a general chevron-shape to target the projectile toward the target. In another embodiment, a thin disk of metal is conformably mounted with the exterior of the container and radially aligned with the direction of fire of the fluid projectile. Depending on the configuration and the amount of explosive and fluid used, a projectile is fired at the target that has sufficient energy to penetrate rigid enclosures from fairly long stand-off and yet is focused enough to be targeted to specific portions of the IED for disablement.
Energy transfer through a multi-layer liner for shaped charges
Skolnick, Saul; Goodman, Albert
1985-01-01
This invention relates to the determination of parameters for selecting materials for use as liners in shaped charges to transfer the greatest amount of energy to the explosive jet. Multi-layer liners constructed of metal in shaped charges for oil well perforators or other applications are selected in accordance with the invention to maximize the penetrating effect of the explosive jet by reference to four parameters: (1) Adjusting the explosive charge to liner mass ratio to achieve a balance between the amount of explosive used in a shaped charge and the areal density of the liner material; (2) Adjusting the ductility of each layer of a multi-layer liner to enhance the formation of a longer energy jet; (3) Buffering the intermediate layers of a multi-layer liner by varying the properties of each layer, e.g., composition, thickness, ductility, acoustic impedance and areal density, to protect the final inside layer of high density material from shattering upon impact of the explosive force and, instead, flow smoothly into a jet; and (4) Adjusting the impedance of the layers in a liner to enhance the transmission and reduce the reflection of explosive energy across the interface between layers.
12 CFR Appendix to Part 1236 - Prudential Management and Operations Standards
Code of Federal Regulations, 2014 CFR
2014-01-01
... risk exposure. Standard 4—Management of Market Risk—Measurement Systems, Risk Limits, Stress Testing... stress test outcomes to adjust its market risk management strategies, policies, and positions and to... entity should use stress test outcomes to adjust its liquidity management strategies, policies, and...
Property-process relations in simulated clinical abrasive adjusting of dental ceramics.
Yin, Ling
2012-12-01
This paper reports on property-process correlations in simulated clinical abrasive adjusting of a wide range of dental restorative ceramics using a dental handpiece and diamond burs. The seven materials studied included four mica-containing glass ceramics, a feldspathic porcelain, a glass-infiltrated alumina, and a yttria-stabilized tetragonal zirconia. The abrasive adjusting process was conducted under simulated clinical conditions using diamond burs and a clinical dental handpiece. An attempt was made to establish correlations between process characteristics in terms of removal rate, chipping damage, and surface finish and material mechanical properties of hardness, fracture toughness and Young's modulus. The results show that the removal rate is mainly a function of hardness, which decreases nonlinearly with hardness. No correlations were noted between the removal rates and the complex relations of hardness, Young's modulus and fracture toughness. Surface roughness was primarily a linear function of diamond grit size and was relatively independent of materials. Chipping damage in terms of the average chipping width decreased with fracture toughness except for glass-infiltrated alumina. It also had higher linear correlations with critical strain energy release rates (R²=0.66) and brittleness (R²=0.62) and a lower linear correlation with indices of brittleness (R²=0.32). Implications of these results can provide guidance for the microstructural design of dental ceramics, optimize performance, and guide the proper selection of technical parameters in clinical abrasive adjusting conducted by dental practitioners. Copyright © 2012 Elsevier Ltd. All rights reserved.
Resolution Quality and Atom Positions in Sub-?ngstr?m Electron Microscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
O'Keefe, Michael A.; Allard Jr, Lawrence Frederick; Blom, Douglas Allen
2005-01-01
John Cowley pioneered use of transmission electron microscopy (TEM) for high-resolution imaging and helped spur improvements in resolution that enabled researchers to pinpoint the positions of all but the lightest atoms within a crystal structure. Sub-{angstrom} capabilities allow imaging of even the lightest atoms. Initially achieved with software aberration correction (focal-series reconstruction of the specimen exit-surface wave), sub-{angstrom} imaging will become commonplace for next-generation electron microscopes with hardware-corrected lenses and monochromated electron beams. Currently, advanced HR-TEMs can image columns of light atoms (carbon, oxygen, nitrogen) in complex structures, including the lithium atoms present in battery materials. The ability to determinemore » whether an image peak represents one single atom (or atom column) instead of several depends on the resolution of the HR-(S)TEM. Rayleigh's resolution criterion, an accepted standard in optics, was derived as a means for judging when two image intensity peaks from two sources of light (stars) are distinguishable from a single source. Atom spacings closer than the Rayleigh limit have been resolved in HR-TEM, suggesting that it may be useful to consider other limits, such as the Sparrow resolution criterion. From the viewpoint of the materials scientist, it is important to be able to use the image to determine whether an image feature represents one or more atoms (resolution), and where the atoms (or atom columns) are positioned relative to one another (resolution quality). When atoms and the corresponding image peaks are separated by more than the Rayleigh limit of the HR-(S)TEM, it is possible to adjust imaging parameters so that relative peak positions in the image correspond to relative atom positions in the specimen. When atoms are closer than the Rayleigh limit, we must find the relationship of the peak position to the atom position by peak fitting or, if we have a suitable model, by image simulation.« less
Investigation of the processing conditions for the synthesis of rod-shaped LiCoO2
NASA Astrophysics Data System (ADS)
Kim, Taejoong; Kim, Yongseon
2018-07-01
We investigate the processing conditions for the synthesis of rod-shaped LiCoO2 (LCO) by a solid-state calcination of a precursor material which was prepared by a hydrothermal method. The rod-like morphology appeared to be easily broken due to the growth of primary crystals recrystallized during the calcination process. Therefore, it is crucial to maintain the temperature under a certain limit. However, the temperature must be high enough to obtain proper crystallinity of the LCO, ideally above 800 °C. Thus, we determined the optimal calcination temperature condition from the common range of temperatures that satisfies both these limiting conditions. The precursor with average diameter of 1 µm sustained the rod shape at calcination temperatures of up to 900 °C; therefore, the optimum calcination temperature could be determined between 800 and 900 °C. Whereas, a proper calcination temperature could not be found for the precursor with 500 nm of diameter because the rod shape did not maintain even at 700 °C. Thus, the maximum temperature at which the rod shape is retained decreases with smaller diameter of the precursor rods, indicating adjusting the diameter above a limiting value is necessary to prepare LCO rod by conventional solid state calcination.
Chen, Jun; Wang, Fangfang; Huang, Qingzhen; Hu, Lei; Song, Xiping; Deng, Jinxia; Yu, Ranbo; Xing, Xianran
2013-01-01
Control of negative thermal expansion is a fundamentally interesting topic in the negative thermal expansion materials in order for the future applications. However, it is a challenge to control the negative thermal expansion in individual pure materials over a large scale. Here, we report an effective way to control the coefficient of thermal expansion from a giant negative to a near zero thermal expansion by means of adjusting the spontaneous volume ferroelectrostriction (SVFS) in the system of PbTiO3-(Bi,La)FeO3 ferroelectrics. The adjustable range of thermal expansion contains most negative thermal expansion materials. The abnormal property of negative or zero thermal expansion previously observed in ferroelectrics is well understood according to the present new concept of spontaneous volume ferroelectrostriction. The present studies could be useful to control of thermal expansion of ferroelectrics, and could be extended to multiferroic materials whose properties of both ferroelectricity and magnetism are coupled with thermal expansion.
Chen, Jun; Wang, Fangfang; Huang, Qingzhen; Hu, Lei; Song, Xiping; Deng, Jinxia; Yu, Ranbo; Xing, Xianran
2013-01-01
Control of negative thermal expansion is a fundamentally interesting topic in the negative thermal expansion materials in order for the future applications. However, it is a challenge to control the negative thermal expansion in individual pure materials over a large scale. Here, we report an effective way to control the coefficient of thermal expansion from a giant negative to a near zero thermal expansion by means of adjusting the spontaneous volume ferroelectrostriction (SVFS) in the system of PbTiO3-(Bi,La)FeO3 ferroelectrics. The adjustable range of thermal expansion contains most negative thermal expansion materials. The abnormal property of negative or zero thermal expansion previously observed in ferroelectrics is well understood according to the present new concept of spontaneous volume ferroelectrostriction. The present studies could be useful to control of thermal expansion of ferroelectrics, and could be extended to multiferroic materials whose properties of both ferroelectricity and magnetism are coupled with thermal expansion. PMID:23949238
Review on electrochromic devices for automotive glazing
NASA Astrophysics Data System (ADS)
Demiryont, Hulya
1991-12-01
Electrochromic materials have been intensively studied for applications of various switchable optical systems. These materials exhibit adjustable optical absorption upon reversible oxidation/reduction processes. Since a reversible oxidation/reduction phenomenon is provided by electrically-driven electrochemical reactions, these materials are known as electrochromics. There are many publications including proceedings, books, and review articles written on electrochromic (EC) materials and their applications. This paper focuses on conventional and some new electrochromic devices (ECD), their specifications, and applications.
Polyelectrolyte multilayers: preparation and applications
NASA Astrophysics Data System (ADS)
Izumrudov, V. A.; Mussabayeva, B. Kh; Murzagulova, K. B.
2018-02-01
The review concerns the results of studies on the synthesis of polyelectrolyte coatings on charged surfaces. These coatings represent nanostructured systems with clearly defined tendency to self-assembly and self-adjustment, which is of particular interest for materials science, biomedicine and pharmacology. A breakthrough in this area of knowledge is due to the development and introduction of a new technique, so-called layer-by-layer (LbL) deposition of nanofilms. The technique is very simple, viz., multilayers are formed as a result of alternating treatment of a charged substrate of arbitrary shape with water-salt solutions of differently charged polyelectrolytes. Nevertheless, efficient use of the LbL method to fabricate nanofilms requires meeting certain conditions and limitations that were revealed in the course of research on model systems. Prospects for applications of polyelectrolyte layers in various fields are discussed. The bibliography includes 58 references.
Drinking water and biofilm disinfection by Fenton-like reaction.
Gosselin, F; Madeira, L M; Juhna, T; Block, J C
2013-10-01
A Fenton-like disinfection process was conducted with Fenton's reagent (H2O2) at pH 3 or 5 on autochthonous drinking water biofilms grown on corroded or non-corroded pipe material. The biofilm disinfection by Fenton-like oxidation was limited by the low content of iron and copper in the biomass grown on non-corroded plumbing. It was slightly improved by spiking the distribution system with some additional iron source (soluble iron II or ferrihydrite particles appeared as interesting candidates). However successful in situ disinfection of biofilms was only achieved in fully corroded cast iron pipes using H2O2 and adjusting the pH to 5. These new results provide additional support for the use of Fenton's processes for cleaning drinking water distribution systems contaminated with biological agents or organics. Copyright © 2013 Elsevier Ltd. All rights reserved.
PVA:LiClO4: a robust, high Tg polymer electrolyte for adjustable ion gating of 2D materials
NASA Astrophysics Data System (ADS)
Kinder, Erich; Fullerton, Susan; CenterLow Energy Systems Technology Team
2015-03-01
Polymer electrolytes are an effective way to gate organic semiconductors and nanomaterials, such as nanotubes and 2D materials, by establishing an electrostatic double layer with large capacitance. Widely used solid electrolytes, such as those based on polyethylene oxide, have a glass transition temperature below room temperature. This permits relatively fast ion mobility at T = 23 °C, but requires a constant applied field to maintain a doping profile. Moreover, PEO-based electrolytes cannot withstand a variety of solvents, limiting its use. Here, we demonstrate a polymer electrolyte using polyvinyl alcohol (PVA) with Tg >23 °C, through which a doping profile can be defined by a potential applied when the polymer is heated above Tg, then ``locked-in'' by cooling the electrolyte to room temperature (
Parental Divorce and Children's Adjustment.
Lansford, Jennifer E
2009-03-01
This article reviews the research literature on links between parental divorce and children's short-term and long-term adjustment. First, I consider evidence regarding how divorce relates to children's externalizing behaviors, internalizing problems, academic achievement, and social relationships. Second, I examine timing of the divorce, demographic characteristics, children's adjustment prior to the divorce, and stigmatization as moderators of the links between divorce and children's adjustment. Third, I examine income, interparental conflict, parenting, and parents well-being as mediators of relations between divorce and children's adjustment. Fourth, I note the caveats and limitations of the research literature. Finally, I consider notable policies related to grounds for divorce, child support, and child custody in light of how they might affect children s adjustment to their parents divorce. © 2009 Association for Psychological Science.
26 CFR 1.803-6 - Amortization of premium and accrual of discount.
Code of Federal Regulations, 2011 CFR
2011-04-01
... (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Life Insurance Companies § 1.803-6 Amortization... held by a life insurance company. Such adjustments are limited to the amount of appropriate... company. A life insurance company which adjusts amortization of premium or accrual of discount with...
26 CFR 1.803-6 - Amortization of premium and accrual of discount.
Code of Federal Regulations, 2013 CFR
2013-04-01
... (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Life Insurance Companies § 1.803-6 Amortization... held by a life insurance company. Such adjustments are limited to the amount of appropriate... company. A life insurance company which adjusts amortization of premium or accrual of discount with...
26 CFR 1.803-6 - Amortization of premium and accrual of discount.
Code of Federal Regulations, 2014 CFR
2014-04-01
... (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Life Insurance Companies § 1.803-6 Amortization... held by a life insurance company. Such adjustments are limited to the amount of appropriate... company. A life insurance company which adjusts amortization of premium or accrual of discount with...
26 CFR 1.803-6 - Amortization of premium and accrual of discount.
Code of Federal Regulations, 2010 CFR
2010-04-01
... (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Life Insurance Companies § 1.803-6 Amortization of premium... held by a life insurance company. Such adjustments are limited to the amount of appropriate... company. A life insurance company which adjusts amortization of premium or accrual of discount with...
26 CFR 1.803-6 - Amortization of premium and accrual of discount.
Code of Federal Regulations, 2012 CFR
2012-04-01
... (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Life Insurance Companies § 1.803-6 Amortization... held by a life insurance company. Such adjustments are limited to the amount of appropriate... company. A life insurance company which adjusts amortization of premium or accrual of discount with...
Early Childhood Profiles of Sleep Problems and Self-Regulation Predict Later School Adjustment
ERIC Educational Resources Information Center
Williams, Kate E.; Nicholson, Jan M.; Walker, Sue; Berthelsen, Donna
2016-01-01
Background: Children's sleep problems and self-regulation problems have been independently associated with poorer adjustment to school, but there has been limited exploration of longitudinal early childhood profiles that include both indicators. Aims: This study explores the normative developmental pathway for sleep problems and self-regulation…
50 CFR 679.25 - Inseason adjustments.
Code of Federal Regulations, 2010 CFR
2010-10-01
... area. (iii) Adjustment of TAC and PSC limits. (iv) Interim closures of statistical areas, or portions... of a statistical area, or portion thereof, under paragraph (a)(1)(iv) of this section, must be based... bycatch rates of prohibited species specified under § 679.21(b) in a statistical area, or portion thereof...
Challenges Facing Chinese International Students Studying in the United States
ERIC Educational Resources Information Center
Ching, Yuerong; Renes, Susan L.; McMurrow, Samantha; Simpson, Joni; Strange, Anthony T.
2017-01-01
Chinese international students often find it challenging to adjust to attending college in the United States (US). There is limited research addressing Chinese international college students' adjustment in the US. Drawing on what literature exists combined with research addressing Chinese immigrants' transition and international students'…
Adjustment to College among Lower Division Students with Disabilities: An Exploratory Study
ERIC Educational Resources Information Center
McNulty, Kristy Lee Ann
2014-01-01
This study utilized a quality of life framework of psychosocial adaptation to explore relationships among college stress, functional limitations, coping strategies, and perceived social suport in adjustment to college among first-year and second-year undergraduate students with disabilities, based on specific hypothesized relations. College…
Bias-correction of PERSIANN-CDR Extreme Precipitation Estimates Over the United States
NASA Astrophysics Data System (ADS)
Faridzad, M.; Yang, T.; Hsu, K. L.; Sorooshian, S.
2017-12-01
Ground-based precipitation measurements can be sparse or even nonexistent over remote regions which make it difficult for extreme event analysis. PERSIANN-CDR (CDR), with 30+ years of daily rainfall information, provides an opportunity to study precipitation for regions where ground measurements are limited. In this study, the use of CDR annual extreme precipitation for frequency analysis of extreme events over limited/ungauged basins is explored. The adjustment of CDR is implemented in two steps: (1) Calculated CDR bias correction factor at limited gauge locations based on the linear regression analysis of gauge and CDR annual maxima precipitation; and (2) Extend the bias correction factor to the locations where gauges are not available. The correction factors are estimated at gauge sites over various catchments, elevation zones, and climate regions and the results were generalized to ungauged sites based on regional and climatic similarity. Case studies were conducted on 20 basins with diverse climate and altitudes in the Eastern and Western US. Cross-validation reveals that the bias correction factors estimated on limited calibration data can be extended to regions with similar characteristics. The adjusted CDR estimates also outperform gauge interpolation on validation sites consistently. It is suggested that the CDR with bias adjustment has a potential for study frequency analysis of extreme events, especially for regions with limited gauge observations.
Bhamidipati, Manjari; Sridharan, BanuPriya; Scurto, Aaron M; Detamore, Michael S.
2013-01-01
The aim of this study was to use CO2 at sub-critical pressures as a tool to sinter 3D, macroporous, microsphere-based scaffolds for bone and cartilage Tissue Engineering Porous scaffolds composed of ~200 µm microspheres of either poly(lactic-co-glycolic acid) (PLGA) or polycaprolactone (PCL) were prepared using dense phase CO2 sintering, which were seeded with rat bone marrow mesenchymal stromal cells (rBMSCs), and exposed to either osteogenic (PLGA, PCL) or chondrogenic (PLGA) conditions for 6 weeks. Under osteogenic conditions, the PLGA constructs produced over an order of magnitude more calcium than the PCL constructs, whereas the PCL constructs had far superior mechanical and structural integrity (125 times stiffer than PLGA constructs) at week 6, along with twice the cell content of the PLGA constructs. Chondrogenic cell performance was limited in PLGA constructs, perhaps as a result of the polymer degradation rate being too high. The current study represents the first long-term culture of CO2-sintered microsphere-based scaffolds, and has established important thermodynamic differences in sintering between the selected formulations of PLGA and PCL, with the former requiring adjustment of pressure only, and the latter requiring the adjustment of both pressure and temperature. Based on more straightforward sintering conditions and more favorable cell performance, PLGA may be the material of choice for microspheres in a CO2 sintering application, although a different PLGA formulation with the encapsulation of growth factors, extracellular matrix-derived nanoparticles, and/or buffers in the microspheres may be advantageous for achieving a more superior cell performance than observed here. PMID:24094202
Nest covering in plovers: How modifying the visual environment influences egg camouflage.
Troscianko, Jolyon; Wilson-Aggarwal, Jared; Spottiswoode, Claire N; Stevens, Martin
2016-10-01
Camouflage is one of the most widespread antipredator defences, and its mechanistic basis has attracted considerable interest in recent years. The effectiveness of camouflage depends on the interaction between an animal's appearance and its background. Concealment can therefore be improved by changes to an animal's own appearance, by behaviorally selecting an optimal background, or by modifying the background to better match the animal's own appearance. Research to date has largely focussed on the first of these mechanisms, whereas there has been little work on the second and almost none on the third. Even though a number of animal species may potentially modify their environment to improve individual-specific camouflage, this has rarely if ever been quantitatively investigated, or its adaptive value tested. Kittlitz's plovers (Charadrius pecuarius) use material (stones and vegetation) to cover their nests when predators approach, providing concealment that is independent of the inflexible appearance of the adult or eggs, and that can be adjusted to suit the local surrounding background. We used digital imaging and predator vision modeling to investigate the camouflage properties of covered nests, and whether their camouflage affected their survival. The plovers' nest-covering materials were consistent with a trade-off between selecting materials that matched the color of the eggs, while resulting in poorer nest pattern and contrast matching to the nest surroundings. Alternatively, the systematic use of materials with high-contrast and small-pattern grain sizes could reflect a deliberate disruptive coloration strategy, whereby high-contrast material breaks up the telltale outline of the clutch. No camouflage variables predicted nest survival. Our study highlights the potential for camouflage to be enhanced by background modification. This provides a flexible system for modifying an animal's conspicuousness, to which the main limitation may be the available materials rather than the animal's appearance.
Support mechanism for a mirrored surface or other arrangement and method
Cutburth, R.W.
1985-11-08
An adjustment mechanism such as a three point spherical mount for adjustably supporting a planer mirror or other type of arrangement relative to a plane defined by a given pair of perpendicular axes is described in this disclosure. This mechanism provides for positioning within the plane defined by the given pair of intersecting perpendicular axes. Limited positioning is possible about either of these axes and provides for a ''non-floating'' center of adjustment.
26 CFR 1.481-2 - Limitation on tax.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 26 Internal Revenue 6 2011-04-01 2011-04-01 false Limitation on tax. 1.481-2 Section 1.481-2 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Adjustments § 1.481-2 Limitation on tax. (a) Three-year allocation. Section 481...
50 CFR 635.34 - Adjustment of management measures.
Code of Federal Regulations, 2012 CFR
2012-10-01
... § 635.23; the quotas for BFT, shark and swordfish, as specified in § 635.27; the marlin landing limit... retention limits, including target catch requirements; size limits; fishing years or fishing seasons; shark... groups to which they belong; species in the prohibited shark species group; classification system within...
50 CFR 635.34 - Adjustment of management measures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... § 635.23; the quotas for BFT, shark and swordfish, as specified in § 635.27; the marlin landing limit... retention limits, including target catch requirements; size limits; fishing years or fishing seasons; shark... groups to which they belong; species in the prohibited shark species group; classification system within...
Evolution of standardized procedures for adjusting lumber properties for change in moisture content
David W. Green; James W. Evans
2001-01-01
This paper documents the development of procedures in American Society for Testing and Materials standards for adjusting the allowable properties of lumber for changes in moisture content. The paper discusses the historical context of efforts to establish allowable properties on a consensus basis, beginning in the 19th century. Where possible, the reasons for proposed...
Quantum Information Science Research and Technical Assessment Project
2010-08-01
parameter space. This system incorporates heaters, deposition monitors, temperature sensors , and adjustable substrate holders and masks under high...thickness monitor; G = glass surfaces for transmission measurements; PD = photodiode; TC = thermocouple temperature sensors . Substrate Preparation...crystal due to the mass of material deposited on the crystal. By adjusting the distance of the sensor relative to the source and employing the ~1/R2
Schwartz, Daniel M
2003-01-01
PURPOSE: First, to determine whether a silicone light-adjustable intraocular lens (IOL) can be fabricated and adjusted precisely with a light delivery device (LDD). Second, to determine the biocompatibility of an adjustable IOL and whether the lens can be adjusted precisely in vivo. METHODS: After fabrication of a light-adjustable silicone formulation, IOLs were made and tested in vitro for cytotoxicity, leaching, precision of adjustment, optical quality after adjustment, and mechanical properties. Light-adjustable IOLs were then tested in vivo for biocompatibility and precision of adjustment in a rabbit model. In collaboration with Zeiss-Meditec, a digital LDD was developed and tested to correct for higher-order aberrations in light-adjustable IOLs. RESULTS: The results establish that a biocompatible silicone IOL can be fabricated and adjusted using safe levels of light. There was no evidence of cytotoxicity or leaching. Testing of mechanical properties revealed no significant differences from commercial controls. Implantation of light-adjustable lenses in rabbits demonstrated- excellent biocompatibility after 6 months, comparable to a commercially available IOL. In vivo spherical (hyperopic and myopic) adjustment in rabbits was achieved using an analog light delivery system. The digital light delivery system was tested and achieved correction of higher-order aberrations. CONCLUSION: A silicone light-adjustable IOL and LDD have been developed to enable postoperative, noninvasive adjustment of lens power. The ability to correct higher-order aberrations in these materials has broad potential applicability for optimization of vision in patients undergoing cataract and refractive surgery. PMID:14971588
Current developments in the practice of individual psychoanalytic psychodrama in France.
Corcos, Maurice; Jeammet, Philippe; Morel, Alexandre; Chabert, Catherine; De Lara, Aline Cohen
2012-06-01
The authors present the history of individual psychoanalytic psychodrama and its current developments as practised in France. They put forward the technique, objectives and rules, along with the indications, limits and risks that ensue from the specific nature of this therapeutic approach. Through its technical adjustments, individual psychoanalytic psychodrama provides a therapeutic option that is appropriate to the defences prevalent in many patients that cause classical psychotherapies to fail: massive inhibition, operative functioning far removed from affects or in false self mode; phobias, disavowal or splitting of the internal psychic life and emotions; prevalence of short discharge circuits in acted-out behaviours and bodily or visceral complaints and expressions. Psychodrama utilizes these defences not in order to eliminate them but to 'subvert' them so that they can continue to carry out their protective role, in particular ensuring narcissistic continuity. At the same time, psychodrama relaxes these defences and facilitates a possible filtering through of the repressed material. Through the number of actors and the diffraction of transference that this allows, psychodrama provides a possibility of adjusting the potentially traumatic effect of the encounter with the object and the instigation of the transference in the regressive dimension induced by any psychotherapeutic process. Copyright © 2012 Institute of Psychoanalysis.
Investigation of hidden periodic structures on SEM images of opal-like materials using FFT and IFFT.
Stephant, Nicolas; Rondeau, Benjamin; Gauthier, Jean-Pierre; Cody, Jason A; Fritsch, Emmanuel
2014-01-01
We have developed a method to use fast Fourier transformation (FFT) and inverse fast Fourier transformation (IFFT) to investigate hidden periodic structures on SEM images. We focused on samples of natural, play-of-color opals that diffract visible light and hence are periodically structured. Conventional sample preparation by hydrofluoric acid etch was not used; untreated, freshly broken surfaces were examined at low magnification relative to the expected period of the structural features, and, the SEM was adjusted to get a very high number of pixels in the images. These SEM images were treated by software to calculate autocorrelation, FFT, and IFFT. We present how we adjusted SEM acquisition parameters for best results. We first applied our procedure on an SEM image on which the structure was obvious. Then, we applied the same procedure on a sample that must contain a periodic structure because it diffracts visible light, but on which no structure was visible on the SEM image. In both cases, we obtained clearly periodic patterns that allowed measurements of structural parameters. We also investigated how the irregularly broken surface interfered with the periodic structure to produce additional periodicity. We tested the limits of our methodology with the help of simulated images. © 2014 Wiley Periodicals, Inc.
Ebeling, Jr., Robert W.; Weaver, Robert B.
1979-01-01
The pressure within a pressurized flow reactor operated under harsh environmental conditions is controlled by establishing and maintaining a fluidized bed of uniformly sized granular material of selected density by passing the gas from the reactor upwardly therethrough at a rate sufficient to fluidize the bed and varying the height of the bed by adding granular material thereto or removing granular material therefrom to adjust the backpressure on the flow reactor.
Method of altering the effective bulk density of solid material and the resulting product
Kool, Lawrence B.; Nolen, Robert L.; Solomon, David E.
1983-01-01
A method of adjustably tailoring the effective bulk density of a solid material in which a mixture comprising the solid material, a film-forming polymer and a volatile solvent are sprayed into a drying chamber such that the solvent evaporates and the polymer dries into hollow shells having the solid material captured within the shell walls. Shell density may be varied as a function of solid/polymer concentration, droplet size and drying temperature.
Horizontal Slide Creates Less Cervical Motion When Centering an Injured Patient on a Spine Board.
DuBose, Dewayne N; Zdziarski, Laura Ann; Scott, Nicole; Conrad, Bryan; Long, Allyson; Rechtine, Glenn R; Prasarn, Mark L; Horodyski, MaryBeth
2016-05-01
A patient with a suspected cervical spine injury may be at risk for secondary neurologic injury when initially placed and repositioned to the center of the spine board. We sought to determine which centering adjustment best limits cervical spine movement and minimizes the chance for secondary injury. Using five lightly embalmed cadaveric specimens with a created global instability at C5-C6, motion sensors were anchored to the anterior surface of the vertebral bodies. Three repositioning methods were used to center the cadavers on the spine board: horizontal slide, diagonal slide, and V-adjustment. An electromagnetic tracking device measured angular (degrees) and translation (millimeters) motions at the C5-C6 level during each of the three centering adjustments. The dependent variables were angular motion (flexion-extension, axial rotation, lateral flexion) and translational displacement (anteroposterior, axial, and medial-lateral). The nonuniform condition produced significantly less flexion-extension than the uniform condition (p = 0.048). The horizontal slide adjustment produced less cervical flexion-extension (p = 0.015), lateral bending (p = 0.003), and axial rotation (p = 0.034) than the V-adjustment. Similarly, translation was significantly less with the horizontal adjustment than with the V-adjustment; medial-lateral (p = 0.017), axial (p < 0.001), and anteroposterior (p = 0.006). Of the three adjustments, our team found that horizontal slide was also easier to complete than the other methods. The horizontal slide best limited cervical spine motion and may be the most helpful for minimizing secondary injury based on the study findings. Copyright © 2016 Elsevier Inc. All rights reserved.
9 CFR 590.430 - Limitation on entry of material.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AGRICULTURE EGG PRODUCTS INSPECTION INSPECTION OF EGGS AND EGG PRODUCTS (EGG PRODUCTS INSPECTION ACT) Entry of Material into Official Egg Products Plants § 590.430 Limitation on entry of material. (a) The Administrator shall limit the entry of eggs and egg products and other materials into official plants under such...
9 CFR 590.430 - Limitation on entry of material.
Code of Federal Regulations, 2011 CFR
2011-01-01
... AGRICULTURE EGG PRODUCTS INSPECTION INSPECTION OF EGGS AND EGG PRODUCTS (EGG PRODUCTS INSPECTION ACT) Entry of Material into Official Egg Products Plants § 590.430 Limitation on entry of material. (a) The Administrator shall limit the entry of eggs and egg products and other materials into official plants under such...
Differences in Self-Reported Physical Limitation Among Older Women and Men in Ismailia, Egypt
2012-01-01
Objectives. This study explores the reasons for gender differences in self-reported physical limitation among older adults in Ismailia, Egypt. Method. 435 women and 448 men, 50 years and older in Ismailia, Egypt, participated in a social survey and tests of physical performance. Ordered logit models were estimated to compare unadjusted gender differences in reported disability with these differences adjusted sequentially for (a) age and objective measures of physical performance, (b) self-reported morbidities and health care use, and (c) social and economic attributes. Results. Compared with men, women more often reported higher levels of limitation in activities of daily living (ADLs), upper-extremity range of motion (ROM), and lower-extremity gross mobility (GM). Adjusting for age and objective measures of physical performance, women and men had similar odds of self-reporting difficulty with ADLs. With sequential adjustments for the remaining variables, women maintained significantly higher odds of self-reported difficulty with upper-extremity ROM and lower-extremity GM. Discussion. Cross-culturally, gender differences in self-reported disability may arise from objective and subjective perceptions of disability. Collectively, these results and those from prior studies in Bangladesh and the United States suggest that gender gaps in self-reported physical limitation may be associated with the degree of gender equality in society. PMID:22929399
Differences in self-reported physical limitation among older women and men in Ismailia, Egypt.
Khadr, Zeinab; Yount, Kathryn
2012-09-01
This study explores the reasons for gender differences in self-reported physical limitation among older adults in Ismailia, Egypt. 435 women and 448 men, 50 years and older in Ismailia, Egypt, participated in a social survey and tests of physical performance. Ordered logit models were estimated to compare unadjusted gender differences in reported disability with these differences adjusted sequentially for (a) age and objective measures of physical performance, (b) self-reported morbidities and health care use, and (c) social and economic attributes. Compared with men, women more often reported higher levels of limitation in activities of daily living (ADLs), upper-extremity range of motion (ROM), and lower-extremity gross mobility (GM). Adjusting for age and objective measures of physical performance, women and men had similar odds of self-reporting difficulty with ADLs. With sequential adjustments for the remaining variables, women maintained significantly higher odds of self-reported difficulty with upper-extremity ROM and lower-extremity GM. Cross-culturally, gender differences in self-reported disability may arise from objective and subjective perceptions of disability. Collectively, these results and those from prior studies in Bangladesh and the United States suggest that gender gaps in self-reported physical limitation may be associated with the degree of gender equality in society.
Study and assessment of segregated biowaste composting: The case study of Attica municipalities.
Malamis, D; Bourka, A; Stamatopoulou, Ε; Moustakas, K; Skiadi, O; Loizidou, M
2017-12-01
This work aims to assess the operation of the first large scale segregated biowaste composting scheme in Greece to divert Household Food Waste (HFW) from landfill and produce a material which can be recovered and used as compost. The source separation and collection of HFW was deployed in selected areas in Attica Region serving about 3700 households. Sorted HFW is collected & transported to the Mechanical and Biological Treatment (MBT) plant in Attica Region that has been designed to produce Compost Like Output (CLO) from mixed MSW. The MBT facility has been adjusted in order to receive and treat aerobically HFW mixed with shredded green waste in a dedicated composting tunnel. The composting process was monitored against temperature, moisture and oxygen content indicating that the biological conditions are sufficiently developed. The product quality was examined and assessed against the quality specifications of EU End of Waste Criteria for biowaste subjected to composting aiming to specify whether the HFW that has undergone recovery ceases to be waste and can be classified as compost. More specifically, the heavy metals concentrations (Cr, Cu, Ni, Cd, Pb, Zn and Hg) are within the set limits and much lower compared to the CLO material that currently is being produced at the MBT plant. In regard to the hygienic requirements of the product it has been found that the process conditions result in a pathogen free material (i.e. E. Coli and Salmonella) which does not favor the growth of viable weeds and plant propagules, while it acquires sufficient organic matter content for soil fertilization. Noticeable physical impurities (mainly fractions of glass) have been detected exceeding the quality control threshold limit of 0.5% w/w (plastics, metals and glass). The latter is related to the missorted materials and to the limited pre-treatment configurations prior to composting. The above findings indicate that effective source separation of biowaste is prerequisite for good quality production and marketing of compost and special consideration should be made to minimize glass impurities prior composting (i.e. awareness raising and pretreatment stage). Therefore, it is feasible to gradually replace the production of questionable quality CLO in MBTs with biowaste compost which is in line with the required quality control standards especially when heavy metals concentrations is concerned. Copyright © 2016 Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-25
... manufactures parts and assemblies. Bracalente Manufacturing Company, Inc. 20 W. Creamery Road, 8/2/2010 The.... electrical wiring harnesses and lighting fixture components whose primary manufacturing material is copper... and Mill, SC 29715. coatings whose manufacturing materials include pigments, resins, solvents...
Filtered cathodic arc deposition with ion-species-selective bias.
Anders, André; Pasaja, Nitisak; Sansongsiri, Sakon
2007-06-01
A dual-cathode arc plasma source was combined with a computer-controlled bias amplifier to synchronize substrate bias with the pulsed production of plasma. In this way, bias can be applied in a material-selective way. The principle has been applied to the synthesis of metal-doped diamondlike carbon films, where the bias was applied and adjusted when the carbon plasma was condensing and the substrate was at ground when the metal was incorporated. In doing so, excessive sputtering by energetic metal ions can be avoided while the sp(3)sp(2) ratio can be adjusted. It is shown that the resistivity of the film can be tuned by this species-selective bias; Raman spectroscopy was used to confirm expected changes of the amorphous ta-C:Mo films. The species-selective bias principle could be extended to multiple material plasma sources and complex materials.
Dallo, Florence J.; Booza, Jason; Nguyen, Norma D.
2013-01-01
Background To examine the association between nativity status (foreign and US-born) by race/ethnicity (Arab, Asian, black, Hispanic, white) on having a functional limitation. Methods We used American Community Survey data (2001-2007; n=1,964,777; 65+ years) and estimated odds ratios (95% confidence intervals). Results In the crude model, foreign-born Blacks, Hispanics and Arabs were more likely, while Asians were less likely to report having a functional limitation compared to white. In the fully adjusted model, Blacks, Hispanics, and Asians were less likely, while Arabs were more likely to report having a functional limitation. In both the crude and fully adjusted models, US-born Blacks and Hispanics were more likely, while Asians and Arabs were less likely to report having a functional limitation compared to whites. Discussion Policies and programs tailored to foreign-born Arab Americans may help prevent or delay the onset of disability, especially when initiated shortly after their arrival to the US. PMID:24165988
Sequential limiting in continuous and discontinuous Galerkin methods for the Euler equations
NASA Astrophysics Data System (ADS)
Dobrev, V.; Kolev, Tz.; Kuzmin, D.; Rieben, R.; Tomov, V.
2018-03-01
We present a new predictor-corrector approach to enforcing local maximum principles in piecewise-linear finite element schemes for the compressible Euler equations. The new element-based limiting strategy is suitable for continuous and discontinuous Galerkin methods alike. In contrast to synchronized limiting techniques for systems of conservation laws, we constrain the density, momentum, and total energy in a sequential manner which guarantees positivity preservation for the pressure and internal energy. After the density limiting step, the total energy and momentum gradients are adjusted to incorporate the irreversible effect of density changes. Antidiffusive corrections to bounds-compatible low-order approximations are limited to satisfy inequality constraints for the specific total and kinetic energy. An accuracy-preserving smoothness indicator is introduced to gradually adjust lower bounds for the element-based correction factors. The employed smoothness criterion is based on a Hessian determinant test for the density. A numerical study is performed for test problems with smooth and discontinuous solutions.
The effects of phosphorus limitation on carbon metabolism in diatoms.
Brembu, Tore; Mühlroth, Alice; Alipanah, Leila; Bones, Atle M
2017-09-05
Phosphorus is an essential element for life, serving as an integral component of nucleic acids, lipids and a diverse range of other metabolites. Concentrations of bioavailable phosphorus are low in many aquatic environments. Microalgae, including diatoms, apply physiological and molecular strategies such as phosphorus scavenging or recycling as well as adjusting cell growth in order to adapt to limiting phosphorus concentrations. Such strategies also involve adjustments of the carbon metabolism. Here, we review the effect of phosphorus limitation on carbon metabolism in diatoms. Two transcriptome studies are analysed in detail, supplemented by other transcriptome, proteome and metabolite data, to gain an overview of different pathways and their responses. Phosphorus, nitrogen and silicon limitation responses are compared, and similarities and differences discussed. We use the current knowledge to propose a suggestive model for the carbon flow in phosphorus-replete and phosphorus-limited diatom cells.This article is part of the themed issue 'The peculiar carbon metabolism in diatoms'. © 2017 The Authors.
The effects of phosphorus limitation on carbon metabolism in diatoms
Alipanah, Leila
2017-01-01
Phosphorus is an essential element for life, serving as an integral component of nucleic acids, lipids and a diverse range of other metabolites. Concentrations of bioavailable phosphorus are low in many aquatic environments. Microalgae, including diatoms, apply physiological and molecular strategies such as phosphorus scavenging or recycling as well as adjusting cell growth in order to adapt to limiting phosphorus concentrations. Such strategies also involve adjustments of the carbon metabolism. Here, we review the effect of phosphorus limitation on carbon metabolism in diatoms. Two transcriptome studies are analysed in detail, supplemented by other transcriptome, proteome and metabolite data, to gain an overview of different pathways and their responses. Phosphorus, nitrogen and silicon limitation responses are compared, and similarities and differences discussed. We use the current knowledge to propose a suggestive model for the carbon flow in phosphorus-replete and phosphorus-limited diatom cells. This article is part of the themed issue ‘The peculiar carbon metabolism in diatoms’. PMID:28717016
Flood Detection/Monitoring Using Adjustable Histogram Equalization Technique
Riaz, Muhammad Mohsin; Ghafoor, Abdul
2014-01-01
Flood monitoring technique using adjustable histogram equalization is proposed. The technique overcomes the limitations (overenhancement, artifacts, and unnatural look) of existing technique by adjusting the contrast of images. The proposed technique takes pre- and postimages and applies different processing steps for generating flood map without user interaction. The resultant flood maps can be used for flood monitoring and detection. Simulation results show that the proposed technique provides better output quality compared to the state of the art existing technique. PMID:24558332
NASA Technical Reports Server (NTRS)
Gordon, Diana F.
1992-01-01
Selecting a good bias prior to concept learning can be difficult. Therefore, dynamic bias adjustment is becoming increasingly popular. Current dynamic bias adjustment systems, however, are limited in their ability to identify erroneous assumptions about the relationship between the bias and the target concept. Without proper diagnosis, it is difficult to identify and then remedy faulty assumptions. We have developed an approach that makes these assumptions explicit, actively tests them with queries to an oracle, and adjusts the bias based on the test results.
Ortiz, Roderick F.
2004-01-01
Effective management of existing water-storage capacity in the Arkansas River Basin is anticipated to help satisfy the need for water in southeastern Colorado. A strategy to meet these needs has been developed, but implementation could affect the water quality of the Arkansas River and Fountain Creek in the vicinity of Pueblo, Colorado. Because no known methods are available to determine what effects future changes in operations will have on water quality, the U.S. Geological Survey, in cooperation with the Southeastern Colorado Water Activity Enterprise, began a study in 2002 to develop methods that could identify if future water-quality conditions have changed significantly from background (preexisting) water-quality conditions. A method was developed to identify when significant departures from background (preexisting) water-quality conditions occur in the lower Arkansas River and Fountain Creek in the vicinity of Pueblo, Colorado. Additionally, the methods described in this report provide information that can be used by various water-resource agencies for an internet-based decision-support tool. Estimated dissolved-solids concentrations at five sites in the study area were evaluated to designate historical background conditions and to calculate tolerance limits used to identify statistical departures from background conditions. This method provided a tool that could be applied with defined statistical probabilities associated with specific tolerance limits. Drought data from 2002 were used to test the method. Dissolved-solids concentrations exceeded the tolerance limits at all four sites on the Arkansas River at some point during 2002. The number of exceedances was particularly evident when streamflow from Pueblo Reservoir was reduced, and return flows and ground-water influences to the river were more prevalent. No exceedances were observed at the site on Fountain Creek. These comparisons illustrated the need to adjust the concentration data to account for varying streamflow. As such, similar comparisons between flow-adjusted data were done. At the site Arkansas River near Avondale, nearly all the 2002 flow-adjusted concentration data were less than the flow-adjusted tolerance limit which illustrated the effects of using flow-adjusted concentrations. Numerous exceedances of the flow-adjusted tolerance limits, however, were observed at the sites Arkansas River above Pueblo and Arkansas River at Pueblo. These results indicated that the method was able to identify a change in the ratio of source waters under drought conditions. Additionally, tolerance limits were calculated for daily dissolved-solids load and evaluated in a similar manner. Several other mass-load approaches were presented to help identify long-term changes in water quality. These included comparisons of cumulative mass load at selected sites and comparisons of mass load contributed at the Arkansas River near Avondale site by measured and unmeasured sources.
20 CFR 416.963 - Your age as a vocational factor.
Code of Federal Regulations, 2012 CFR
2012-04-01
... your residual functional capacity, education, and work experience. We will not consider your ability to... person's ability to adjust to other work, we consider advancing age to be an increasingly limiting factor... this section. If you are unemployed but you still have the ability to adjust to other work, we will...
20 CFR 404.1563 - Your age as a vocational factor.
Code of Federal Regulations, 2012 CFR
2012-04-01
... your residual functional capacity, education, and work experience. We will not consider your ability to... person's ability to adjust to other work, we consider advancing age to be an increasingly limiting factor... this section. If you are unemployed but you still have the ability to adjust to other work, we will...
ERIC Educational Resources Information Center
Okado, Yuko; Haskett, Mary E.
2015-01-01
Background: There is limited knowledge about how positive and negative parenting practices differ across individuals and change over time in parents with substantiated physical abuse history, and how trajectories of these parenting practices affect child adjustment. Objective: The present study examined latent trajectories of positive and negative…
Age-Adjustment and Related Epidemiology Rates in Education and Research
ERIC Educational Resources Information Center
Baker, John D.; Kruckman, Laurence; George, Joyce
2006-01-01
A quick review of introductory textbooks reveals that while gerontology authors and instructors introduce some aspect of demography and epidemiology data, there is limited focus on age adjustment or other important epidemiology rates. The goal of this paper is to reintroduce a variety of basic epidemiology strategies such as incidence, prevalence,…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-04
... alternatives for each of three principal management measures: (1) The primary possession limit affecting the... Management Plan (Skate FMP). Framework Adjustment 1 was developed by the New England Fishery Management... (IRFA), are available on request from Paul J. Howard, Executive Director, New England Fishery Management...
ERIC Educational Resources Information Center
Bohnert, Amy M.; Aikins, Julie Wargo; Arola, Nicole T.
2013-01-01
Although organized activities (OAs) have been established as important contexts of development, limited work has examined the role of OAs across the high school transition in buffering adolescents' social adjustment by providing opportunities for visibility and peer affiliation. The transition to high school is characterized by numerous changes…
Empirical evidence for resource-rational anchoring and adjustment.
Lieder, Falk; Griffiths, Thomas L; M Huys, Quentin J; Goodman, Noah D
2018-04-01
People's estimates of numerical quantities are systematically biased towards their initial guess. This anchoring bias is usually interpreted as sign of human irrationality, but it has recently been suggested that the anchoring bias instead results from people's rational use of their finite time and limited cognitive resources. If this were true, then adjustment should decrease with the relative cost of time. To test this hypothesis, we designed a new numerical estimation paradigm that controls people's knowledge and varies the cost of time and error independently while allowing people to invest as much or as little time and effort into refining their estimate as they wish. Two experiments confirmed the prediction that adjustment decreases with time cost but increases with error cost regardless of whether the anchor was self-generated or provided. These results support the hypothesis that people rationally adapt their number of adjustments to achieve a near-optimal speed-accuracy tradeoff. This suggests that the anchoring bias might be a signature of the rational use of finite time and limited cognitive resources rather than a sign of human irrationality.
Plastic deformation treated as material flow through adjustable crystal lattice
NASA Astrophysics Data System (ADS)
Minakowski, P.; Hron, J.; Kratochvíl, J.; Kružík, M.; Málek, J.
2014-08-01
Looking at severe plastic deformation experiments, it seems that crystalline materials at yield behave as a special kind of anisotropic, highly viscous fluids flowing through an adjustable crystal lattice space. High viscosity provides a possibility to describe the flow as a quasi-static process, where inertial and other body forces can be neglected. The flow through the lattice space is restricted to preferred crystallographic planes and directions causing anisotropy. In the deformation process the lattice is strained and rotated. The proposed model is based on the rate form of the decomposition rule: the velocity gradient consists of the lattice velocity gradient and the sum of the velocity gradients corresponding to the slip rates of individual slip systems. The proposed crystal plasticity model allowing for large deformations is treated as the flow-adjusted boundary value problem. As a test example we analyze a plastic flow of an single crystal compressed in a channel die. We propose three step algorithm of finite element discretization for a numerical solution in the Arbitrary Lagrangian Eulerian (ALE) configuration.
Amemiya, Airi; Fujiwara, Takeo; Murayama, Hiroshi; Tani, Yukako; Kondo, Katsunori
2018-01-16
A life-course perspective is essential in understanding the determinants of higher-level functional limitations. We examine the impact of adverse childhood experiences (ACEs) on higher-level functional limitations in older people. Data were from the Japan Gerontological Evaluation Study 2013, a population-based cohort of independent people aged 65 years or older across Japan (n = 19,220). ACEs before the age of 18 were assessed in terms of seven adversities: parental death, parental divorce, parental mental illness, family violence, physical abuse, psychological neglect, and psychological abuse. Associations between the cumulative number of ACEs and higher-level functional limitations were investigated by multivariate Poisson regression with robust error variances, adjusted for age, gender, childhood disadvantage, adult sociodemographics, adult health behaviors, and health status. Of the older people, 36.3% reported at least one ACE. Older people who had experienced two or more ACEs showed significantly greater higher-level functional limitations than those with no ACE in a crude model (prevalence ratio, PR = 1.61, 95% confidence interval, CI = 1.51-1.71). After adjusting the covariates, this association remained (PR = 1.19, 95% CI = 1.12-1.27). ACEs showed robust independent effects on higher-level functional limitations among older Japanese without disabilities, even after adjusting for potential covariates in childhood and adulthood. The current findings may help in understanding the impact of the latent effects of ACEs on functional limitations in older people. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Chan, Siew Foong; Deeks, Jonathan J; Macaskill, Petra; Irwig, Les
2008-01-01
To compare three predictive models based on logistic regression to estimate adjusted likelihood ratios allowing for interdependency between diagnostic variables (tests). This study was a review of the theoretical basis, assumptions, and limitations of published models; and a statistical extension of methods and application to a case study of the diagnosis of obstructive airways disease based on history and clinical examination. Albert's method includes an offset term to estimate an adjusted likelihood ratio for combinations of tests. Spiegelhalter and Knill-Jones method uses the unadjusted likelihood ratio for each test as a predictor and computes shrinkage factors to allow for interdependence. Knottnerus' method differs from the other methods because it requires sequencing of tests, which limits its application to situations where there are few tests and substantial data. Although parameter estimates differed between the models, predicted "posttest" probabilities were generally similar. Construction of predictive models using logistic regression is preferred to the independence Bayes' approach when it is important to adjust for dependency of tests errors. Methods to estimate adjusted likelihood ratios from predictive models should be considered in preference to a standard logistic regression model to facilitate ease of interpretation and application. Albert's method provides the most straightforward approach.
Work limitations, workplace concerns, and job satisfaction of persons with chronic disease.
Siu, Andrew M H; Hung, Anchor; Lam, Ada Y L; Cheng, Andy
2013-01-01
This study investigates the workplace experiences of people with chronic diseases, including their work limitations, emotional health, concerns about discrimination, and support from colleagues and employer. This study identifies the factors that contribute to work adjustment (job tenure and job satisfaction). A purposive sample of 136 persons aged 18 to 60 with chronic diseases who had been employed in the past 6 months completed a survey about their workplace experience. The questionnaire included several standardized instruments: the Perceived Health and Self-efficacy in Managing Chronic Disease Scale, Work Limitations Questionnaire, Overall Job Satisfaction Scale, and the Depression Anxiety Stress Scale-21. The researchers also designed original items to measure concerns about discriminatory practices, workplace support, and self-stigma. Persons with chronic diseases were fairly satisfied with their jobs and had extended stays in those jobs. They reported a minor productivity loss and physical limitations. Most participants let co-workers, employers, and supervisors know they had chronic disease, but they were concerned about the support those people provide. Participants were more likely to be highly satisfied with their jobs if they had high self-efficacy in managing their disease, perceived more workplace support, and had less work limitations (especially output demands). Job tenure is associated age, education, and monthly income, but not clinical indicators. Persons with chronic disease who were able to maintain good work adjustment tended to be "fit" with few work limitations and little emotional distress. The key factors affecting work adjustment were efficacy in managing their disease, workplace support, and output demands.
Green, Jamie A; Mor, Maria K; Shields, Anne Marie; Sevick, Mary Ann; Arnold, Robert M; Palevsky, Paul M; Fine, Michael J; Weisbord, Steven D
2013-07-01
Although limited health literacy is common in hemodialysis patients, its effects on clinical outcomes are not well understood. Observational study. 260 maintenance hemodialysis patients enrolled in a randomized clinical trial of symptom management strategies from January 2009 through April 2011. Limited health literacy. Dialysis adherence (missed and abbreviated treatments) and health resource utilization (emergency department visits and end-stage renal disease [ESRD]-related hospitalizations). We assessed health literacy using the Rapid Estimate of Adult Literacy in Medicine (REALM) and used negative binomial regression to analyze the independent associations of limited health literacy with dialysis adherence and health resource utilization over 12-24 months. 41 of 260 (16%) patients showed limited health literacy (REALM score, ≤60). There were 1,152 missed treatments, 5,127 abbreviated treatments, 552 emergency department visits, and 463 ESRD-related hospitalizations. Limited health literacy was associated independently with an increased incidence of missed dialysis treatments (missed, 0.6% vs 0.3%; adjusted incidence rate ratio [IRR], 2.14; 95% CI, 1.10-4.17), emergency department visits (annual visits, 1.7 vs 1.0; adjusted IRR, 1.37; 95% CI, 1.01-1.86), and hospitalizations related to ESRD (annual hospitalizations, 0.9 vs 0.5; adjusted IRR, 1.55; 95% CI, 1.03-2.34). Generalizability and potential for residual confounding. Patients receiving maintenance hemodialysis who have limited health literacy are more likely to miss dialysis treatments, use emergency care, and be hospitalized related to their kidney disease. These findings have important clinical practice and cost implications. Copyright © 2013 National Kidney Foundation, Inc. All rights reserved.
Pastor, Patricia N; Reuben, Cynthia A; Kobau, Rosemarie; Helmers, Sandra L; Lukacs, Susan
2015-04-01
Epilepsy is a common serious neurologic disorder in children. However, most studies of children's functional difficulties and school limitations have used samples from tertiary care or other clinical settings. To compare functional difficulties and school limitations of a national sample of US children with special health care needs (CSHCN) with and without epilepsy. Data from the 2009-2010 National Survey of CSHCN for 31,897 children aged 6-17 years with and without epilepsy were analyzed for CSHCN in two groups: 1) CSHCN with selected comorbid conditions (intellectual disability, cerebral palsy, autism, or traumatic brain injury) and 2) CSHCN without these conditions. Functional difficulties and school limitations, adjusted for the effect of sociodemographic characteristics, were examined by epilepsy and comorbid conditions. Three percent of CSHCN had epilepsy. Among CSHCN with epilepsy 53% had comorbid conditions. Overall CSHCN with epilepsy, both with and without comorbid conditions, had more functional difficulties than CSHCN without epilepsy. For example, after adjustment for sociodemographic characteristics a higher percentage of children with epilepsy, compared to children without epilepsy, had difficulty with communication (with conditions: 53% vs. 37%, without conditions: 13% vs. 5%). Results for school limitations were similar. After adjustment, a higher percentage of children with epilepsy, compared to children without epilepsy, missed 11 + school days in the past year (with conditions: 36% vs. 18%, without conditions: 21% vs. 15%). CSHCN with epilepsy, compared to CSHCN without epilepsy, were more likely to have functional difficulties and limitations in school attendance regardless of comorbid conditions. Published by Elsevier Inc.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-26
... Pacific Ocean perch) will increase slightly with the adjustments to the cumulative limits in the limited..., projected impacts to Pacific Ocean perch (POP), darkblotched rockfish, and widow rockfish are also reduced... regulatory discards, while balancing the risk of inducing effort shifts to convert the trip limit from an...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-14
... Fishery; Trip Limit Adjustments for the Common Pool Fishery AGENCY: National Marine Fisheries Service... Northeast multispecies common pool vessels for the remainder of the 2012 fishing year. This rule also... total catch of these stocks to approach their pertinent common pool sub-annual catch limits sub-annual...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-13
... Fishery; Trip Limit Adjustments for the Common Pool Fishery AGENCY: National Marine Fisheries Service...) multispecies common pool vessels for the remainder of the 2011 fishing year (FY), through April 30, 2012. This... catch of these stocks to approach their pertinent common pool sub-annual catch limits (sub-ACLs). DATES...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-05
... Fishery; Trip Limit Adjustments for the Common Pool Fishery AGENCY: National Marine Fisheries Service... (NE) multispecies common pool vessels for the 2010 fishing year (FY), through April 30, 2011. This... common pool sub-annual catch limits (sub-ACLs). This action is also intended to reduce catch rates of GOM...
Campbell, Michael H; Palmieri, Michael; Lasch, Brandi
2006-12-01
The concurrent validity of the College Adjustment Scales was assessed using comparison to the College Maladjustment Scale of the Minnesota Multiphasic Inventory-2. Undergraduate students (N=56, 40 women, M age = 21.3 yr., 87.5% white, non-Hispanic) completed both tests. Analysis indicated scores on 8 of 9 College Adjustment Scales correlated significantly in the predicted direction with those on the College Maladjustment Scale, thereby providing some additional support for convergent validity. While the conclusions are limited significantly by the small sample, this report provides an incremental contribution to the validity of the College Adjustment Scales.
Oelsner, Elizabeth C; Carr, J Jeffrey; Enright, Paul L; Hoffman, Eric A; Folsom, Aaron R; Kawut, Steven M; Kronmal, Richard A; Lederer, David J; Lima, Joao A C; Lovasi, Gina S; Smith, Benjamin M; Shea, Steven J; Barr, R Graham
2016-07-01
Emphysema on CT is a risk factor for all-cause mortality in persons with and without airflow obstruction; however, causes of death associated with emphysema remain uncertain, particularly in the general population. To test associations between quantitatively assessed emphysema on CT and cause of death in persons with and without a substantial smoking history. The Multi-Ethnic Study of Atherosclerosis recruited 6814 participants, aged 45-84 years and without clinical cardiovascular disease, in 2000-2002. Per cent emphysema was defined on cardiac CT as per cent of lung voxels less than -950 Hounsfield units; emphysema on CT was defined as per cent emphysema above the upper limit of normal. Cause of death was classified by administrative codes. Proportional-hazards models were adjusted for age, race/ethnicity, gender, body mass index, smoking status, pack-years, coronary artery calcium, site and education. Additional adjustment for lung function was made in a subset with spirometry from 2004 to 2006. There were 1091 deaths over 12 years median follow-up. Emphysema on CT was strongly associated with increased mortality due to respiratory diseases (adjusted HR 2.94, 95% CI 1.68 to 5.15), particularly chronic lower respiratory diseases (adjusted HR 9.54, 95% CI 4.70 to 19.35), and lung cancer (adjusted HR 1.84, 95% CI 1.09 to 3.12), but not cardiovascular disease. Associations persisted among participants with fewer than 10 pack-years and those without physician-diagnosed respiratory disease, and were similar after adjustment for airflow measures and in persons without airflow limitation. Quantitatively assessed emphysema on CT is associated with greater respiratory disease and lung cancer mortality, even among persons without traditional risk factors. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Jaakkola, J J; Oie, L; Nafstad, P; Botten, G; Samuelsen, S O; Magnus, P
1999-01-01
OBJECTIVES: This study assessed the role of polyvinyl chloride (PVC) plastics and textile materials in the home in the development of bronchial obstruction during the first 2 years of life. METHODS: The study was a matched pair case-control study based on a cohort of 3754 newborns in Oslo in 1992 and 1993 who were followed up for 2 years. The case group consisted of 251 children with bronchial obstruction; the control group was matched one-to-one for date of birth. RESULTS: In conditional logistic regression analysis, the risk of bronchial obstruction was related to the presence of PVC flooring (adjusted odds ratio [OR] = 1.89; 95% confidence interval [CI] = 1.14, 3.14) and textile wall materials (adjusted OR = 1.58; 95% CI = 0.98, 2.54). The reference category was wood or parquet flooring and painted walls and ceiling. Further analysis revealed an exposure-response relationship between the assessed amount of PVC and other plasticizer-containing surface materials and the risk of bronchial obstruction. CONCLUSIONS: This study provides new evidence of the role of PVC and textile wall materials in the development of bronchial obstruction in young children. PMID:9949747
Jaakkola, J J; Oie, L; Nafstad, P; Botten, G; Samuelsen, S O; Magnus, P
1999-02-01
This study assessed the role of polyvinyl chloride (PVC) plastics and textile materials in the home in the development of bronchial obstruction during the first 2 years of life. The study was a matched pair case-control study based on a cohort of 3754 newborns in Oslo in 1992 and 1993 who were followed up for 2 years. The case group consisted of 251 children with bronchial obstruction; the control group was matched one-to-one for date of birth. In conditional logistic regression analysis, the risk of bronchial obstruction was related to the presence of PVC flooring (adjusted odds ratio [OR] = 1.89; 95% confidence interval [CI] = 1.14, 3.14) and textile wall materials (adjusted OR = 1.58; 95% CI = 0.98, 2.54). The reference category was wood or parquet flooring and painted walls and ceiling. Further analysis revealed an exposure-response relationship between the assessed amount of PVC and other plasticizer-containing surface materials and the risk of bronchial obstruction. This study provides new evidence of the role of PVC and textile wall materials in the development of bronchial obstruction in young children.
Ballistic Resistance of Body Armor. NIJ Standard-0101.06
2008-07-01
49.2 ft ± 3.28 ft) Length to be adjusted to meet velocity accuracy requirements Test Barrel Armor Panel Backing Material Fixture Start Sensor Set...Systems, Testing and Evaluation Amanda Forster, Materials Research Engineer The preparation of this standard was sponsored by the National...manufacturers seek NIJ compliance of their armor to this standard and the armor contains unique materials or forms of construction that may not have
Correlating Fast Fluence to dpa in Atypical Locations
NASA Astrophysics Data System (ADS)
Drury, Thomas H.
2016-02-01
Damage to a nuclear reactor's materials by high-energy neutrons causes changes in the ductility and fracture toughness of the materials. The reactor vessel and its associated piping's ability to withstand stress without brittle fracture are paramount to safety. Theoretically, the material damage is directly related to the displacements per atom (dpa) via the residual defects from induced displacements. However in practice, the material damage is based on a correlation to the high-energy (E > 1.0 MeV) neutron fluence. While the correlated approach is applicable when the material in question has experienced the same neutron spectrum as test specimens which were the basis of the correlation, this approach is not generically acceptable. Using Monte Carlo and discrete ordinates transport codes, the energy dependent neutron flux is determined throughout the reactor structures and the reactor vessel. Results from the models provide the dpa response in addition to the high-energy neutron flux. Ratios of dpa to fast fluence are calculated throughout the models. The comparisons show a constant ratio in the areas of historical concern and thus the validity of the correlated approach to these areas. In regions above and below the fuel however, the flux spectrum has changed significantly. The correlated relationship of material damage to fluence is not valid in these regions without adjustment. An adjustment mechanism is proposed.
Li, Ying; Li, Chengfa; Xiao, Daoqing; Liang, Feng; Chen, Zhinan; Schen, Xuhui; Sun, Xiaoying; Li, Yongtao
2013-01-01
A solid phase extraction (SPE) combination with gas chromatography-mass spectrometry (GC-MS) was developed for the determination of the migration of 25 primary aromatic amines (PAAs) from food contact plastic materials and articles. The samples were extracted by deionized water and 30 g/L acetic acid, and the pH value of the solution was adjusted to 8 - 10 with ammonia. The extracts were cleaned up and concentrated on an SPE column, then eluted by equal volume of methyl-tert-butyl ether and ethanol. The analysis of the target compounds was performed by GC-MS. The results indicated that the limits of detection were in the range of 0.4 -2.0 microg/kg for different PAAs. The recoveries and relative standard deviations (n = 7) of 10 microg/kg PAAs ranged from 51.6% -118.4% and 0.5% -9.8%, respectively, except the 2,4-diaminoanisole in the acid simulant. The effects of different experimental conditions such as the pH value and volume ratio of methyl-tert-butyl ether and ethanol were studied. The results showed that the method is accurate and stable, and could meet the requirement of the European Commission Regulation (EU) No 10/2011 for the determination of primary aromatic amines. It can be applied in the analysis of the primary aromatic amines in real food contact plastic material and article samples.
Near-Infrared (0.67-4.7 microns) Optical Constants Estimated for Montmorillonite
NASA Technical Reports Server (NTRS)
Roush, T. L.
2005-01-01
Various models of the reflectance from particulate surfaces are used for interpretation of remote sensing data of solar system objects. These models rely upon the real (n) and imaginary (k) refractive indices of the materials. Such values are limited for commonly encountered silicates at visual and near-infrared wavelengths (lambda, 0.4-5 microns). Availability of optical constants for candidate materials allows more thorough modeling of the observations obtained by Earth-based telescopes and spacecraft. Two approaches for determining the absorption coefficient (alpha=2pik/lambda) from reflectance measurements of particulates have been described; one relies upon Kubelka-Munk theory and the other Hapke theory. Both have been applied to estimate alpha and k for various materials. Neither enables determination of the wavelength dependence of n, n=f(lambda). Thus, a mechanism providing this ability is desirable. Using Hapke-theory to estimate k from reflectance measurements requires two additional quantities be known or assumed: 1) n=f(lambda) and 2) d, the sample particle diameter. Typically n is assumed constant (c) or modestly varying with lambda; referred to here as n(sub 0). Assuming n(sub 0), at each lambda an estimate of k is used to calculate the reflectance and is iteratively adjusted until the difference between the model and measured reflectance is minimized. The estimated k's (k(sub 1)) are the final results, and this concludes the typical analysis.
Health-Related Quality of Life Among US Workers: Variability Across Occupation Groups.
Shockey, Taylor M; Zack, Matthew; Sussell, Aaron
2017-08-01
To examine the health-related quality of life among workers in 22 standard occupation groups using data from the 2013-2014 US Behavioral Risk Factor Surveillance System. We examined the health-related quality of life measures of self-rated health, frequent physical distress, frequent mental distress, frequent activity limitation, and frequent overall unhealthy days by occupation group for 155 839 currently employed adults among 17 states. We performed multiple logistic regression analyses that accounted for the Behavioral Risk Factor Surveillance System's complex survey design to obtain prevalence estimates adjusted for potential confounders. Among all occupation groups, the arts, design, entertainment, sports, and media occupation group reported the highest adjusted prevalence of frequent physical distress, frequent mental distress, frequent activity limitation, and frequent overall unhealthy days. The personal care and service occupation group had the highest adjusted prevalence for fair or poor self-rated health. Workers' jobs affect their health-related quality of life.
NASA Astrophysics Data System (ADS)
Jacobs, Stephen D.
2011-10-01
Deterministic final polishing of high precision optics using sub-aperture processing with magnetorheological finishing (MRF) is an accepted practice throughout the world. A wide variety of materials can be successfully worked with aqueous (pH 10), magnetorheological (MR) fluids, using magnetic carbonyl iron (CI) and either ceria or nanodiamond nonmagnetic abrasives. Polycrystalline materials like zinc sulfide (ZnS) and zinc selenide (ZnSe) are difficult to polish at pH 10 with MRF, due to their grain size and the relatively low stiffness of the MR fluid lap. If microns of material are removed, the grain structure of the material begins to appear. In 2005, Kozhinova et al. (Appl. Opt. 44 4671-4677) demonstrated that lowering pH could improve MRF of ZnS. However, magnetic CI particle corrosion rendered their low pH approach unstable and unsuitable for commercial implementation. In 2009, Shafrir et al. described a sol-gel coating process for manufacturing a zirconia-coated CI particle that protects the magnetic core from aqueous corrosion (Appl. Opt .48 6797-6810). The coating process produces free nanozirconia polishing abrasives during the coating procedure, thereby creating an MR polishing powder that is "self-charged" with the polishing abrasive. By simply adding water, it was possible to polish optical glasses and ceramics with good stability at pH 8 for three weeks. The development of a corrosion resistant, MR polishing powder, opens up the possibility for polishing additional materials, wherein the pH may be adjusted to optimize effectiveness. In this paper we describe the CI coating process, the characterization of the coated powder, and procedures for making stable MR fluids with adjustable pH, giving polishing results for a variety of optical glasses and crystalline ceramics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Xiang; Sokolov, Mikhail A; Nanstad, Randy K
Material fracture toughness in the fully ductile region can be described by a J-integral vs. crack growth resistance curve (J-R curve). As a conventional J-R curve measurement method, the elastic unloading compliance (EUC) method becomes impractical for elevated temperature testing due to relaxation of the material and friction induced back-up shape of the J-R curve. One alternative solution of J-R curve testing applies the Direct Current Potential Drop (DCPD) technique for measuring crack extension. However, besides crack growth, potential drop can also be influenced by plastic deformation, crack tip blunting, etc., and uncertainties exist in the current DCPD methodology especiallymore » in differentiating potential drop due to stable crack growth and due to material deformation. Thus, using DCPD for J-R curve determination remains a challenging task. In this study, a new adjustment procedure for applying DCPD to derive the J-R curve has been developed for conventional fracture toughness specimens, including compact tension, three-point bend, and disk-shaped compact specimens. Data analysis has been performed on Oak Ridge National Laboratory (ORNL) and American Society for Testing and Materials (ASTM) interlaboratory results covering different specimen thicknesses, test temperatures, and materials, to evaluate the applicability of the new DCPD adjustment procedure for J-R curve characterization. After applying the newly-developed procedure, direct comparison between the DCPD method and the normalization method on the same specimens indicated close agreement for the overall J-R curves, as well as the provisional values of fracture toughness near the onset of ductile crack extension, Jq, and of tearing modulus.« less
Enabling laser applications in microelectronics manufacturing
NASA Astrophysics Data System (ADS)
Delmdahl, Ralph; Brune, Jan; Fechner, Burkhard; Senczuk, Rolf
2016-02-01
In this experimental study, we report on high-pulse-energy excimer laser drilling into high-performance build-up films which are pivotal in microelectronics manufacturing. Build-up materials ABF-GX13 from Ajinomoto as well as ZS-100 from Zeon Corporation are evaluated with respect to their viability for economic excimer laser-based micro-via formation. Excimer laser mask imaging projection at laser wavelengths of 193, 248 and 308 nm is employed to generate matrices of smaller micro-vias with different diameters and via pitches. High drilling quality is achievable for all excimer laser wavelengths with the fastest ablation rates measured in the case of 248 and 308 nm wavelengths. The presence of glass fillers in build-up films as in the ABF-GX13 material poses some limitations to the minimum achievable via diameter. However, surprisingly good drilling results are obtainable as long as the filler dimensions are well below the diameter of the micro-vias. Sidewall angles of vias are controllable by adjusting the laser energy density and pulse number. In this work, the structuring capabilities of excimer lasers in build-up films as to taper angle variations, attainable via diameters, edge-stop behavior and ablation rates will be elucidated.
Understandability of Patient Information Booklets for Patients with Cancer.
Keinki, Christian; Zowalla, Richard; Wiesner, Martin; Koester, Marie Jolin; Huebner, Jutta
2018-06-01
The improvement of health literacy in general and the information of individual patient is a major concern of the German national cancer plan and similar initiatives in other western countries. The aim of our study was to assess the readability and understandability of information booklets for cancer patients available at German Web sites. A support vector machine (SVM) was used to discriminate between laymen- and expert-centric patient information booklets about nine most common tumor types. All booklets had to be available for free at the Internet. A total of 52 different patient booklets were downloaded and assessed. Overall, the assessment of all booklets showed that an understandability level L of 4.6 and therefore increased medical background knowledge is required to understand a random text selected from the sample. The assessed information booklets on cancer show very limited suitability for laymen. We were able to demonstrate that a medical background is necessary to understand the examined booklets. The current study highlights the need to create information material adjusted to the needs of laymen. Assessing understandability before publication, especially for laymen with low health literacy, could ensure the suitability and thus quality of the information material.
Organic photochromics for spatial light modulation
NASA Astrophysics Data System (ADS)
Kirkby, C. J. G.; Bennion, I.
1986-02-01
The feasibility of using fulgide derivatives (FD), a class of thermally stable, fatigue-free photochromic materials (PM), as optically addressed spatial light modulators (SLIM) is analyzed. Photochromism is the property of a material that changes from one physicochemical state to another due to the impingement of light. The PMs are low-resolution but exhibit no granularity as photographic films do, therefore permitting the use of PMs as data or image recording media with direct-read-after-write capability. It is known that the properties of the FDs (of dimethyl succinic anhydride), i.e., the fatigue, thermal stability and absorption band location, can be tailored by control of the location of two of the oxygen links at two locations on the molecule. Manipulating the absorption spectra also allows manipulation of the refractive index, ergo the SLIM capability of the FDs. Molecular substitutions have proven effective for adjustments of the wavelength sensitivities of the FDs. Film thicknesses of 3-10 microns have been shown capable of supporting a practical resolution limit of 100-200 line pairs/mm, a 30 dB dynamic range, a Fourier plane SNR of 50, and an image recycle time of 40 msec.
Koo, Hyeon-Kyoung; Jin, Kwang Nam; Kim, Deog Kyeom; Chung, Hee Soon; Lee, Chang-Hoon
2016-01-01
Objectives Emphysema is one of the prognostic factors for rapid lung function decline in patients with COPD, but the impact of incidentally detected emphysema on population without spirometric abnormalities has not been evaluated. This study aimed to determine whether emphysema detected upon computed tomography (CT) screening would accelerate the rate of lung function decline and influence the possibility of future development of airflow limitation in a population without spirometric abnormalities. Materials and methods Subjects who participated in a routine screening for health checkup and follow-up pulmonary function tests for at least 3 years between 2004 and 2010 were retrospectively enrolled. The percentage of low-attenuation area below −950 Hounsfield units (%LAA−950) was calculated automatically. A calculated value of %LAA−950 that exceeded 10% was defined as emphysema. Adjusted annual lung function decline was analyzed using random-slope, random-intercept mixed linear regression models. Results A total of 628 healthy subjects within the normal range of spriometric values were included. Multivariable analysis showed that the emphysema group exhibited a faster decline in forced vital capacity (−33.9 versus −18.8 mL/year; P=0.02). Emphysema was not associated with the development of airflow limitation during follow-up. Conclusion Incidental emphysema quantified using CT scan was significantly associated with a more rapid decline in forced vital capacity in the population with normative spirometric values. However, an association between emphysema and future development of airflow limitation was not observed. PMID:26893550
Long, Kristin A; Lehmann, Vicky; Gerhardt, Cynthia A; Carpenter, Aubrey L; Marsland, Anna L; Alderfer, Melissa A
2018-06-01
Siblings' psychosocial adjustment to childhood cancer is poorly understood. This systematic review summarizes findings and limitations of the sibling literature since 2008, provides clinical recommendations, and offers future research directions. MEDLINE/Pubmed, Cumulative Index to Nursing and Allied Health Literature, and PsycINFO were searched for articles related to siblings, psychosocial functioning, and pediatric cancer. After systematic screening, studies meeting inclusion criteria were rated for scientific merit, and findings were extracted and synthesized. In total, 102 studies were included (63 quantitative, 35 qualitative, 4 mixed-methods). Methodological limitations are common. Mean levels of anxiety, depression, and general adjustment are similar across siblings and comparisons, but symptoms of cancer-related posttraumatic stress are prevalent. School-aged siblings display poorer academic functioning and more absenteeism but similar peer relationships as peers. Quality of life findings are mixed. Adult siblings engage in higher levels of risky health behaviors and may have poorer health outcomes than comparisons. Risk factors for poor sibling adjustment include lower social support, poorer family functioning, lower income, non-White race, and shorter time since diagnosis, but findings are inconsistent. Qualitative themes include siblings' maturity, compassion, and autonomy, but also strong negative emotions, uncertainty, family disruptions, limited parental support, school problems, altered friendships, and unmet needs. Despite methodological limitations, research indicates a strong need for sibling support. Clinical recommendations include identifying at-risk siblings and developing interventions to facilitate family communication and increase siblings' social support, cancer-related knowledge, and treatment involvement. Future longitudinal studies focusing on mechanisms and moderators of siblings' adjustment would inform timing and targets of psychosocial care. Copyright © 2018 John Wiley & Sons, Ltd.
Practice, clinical management, and financial arrangements of practicing generalists.
Keating, Nancy L; Landon, Bruce E; Ayanian, John Z; Borbas, Catherine; Guadagnoli, Edward
2004-05-01
To describe the practice settings, financial arrangements, and management strategies experienced by generalist physicians and identify factors associated with reporting pressure to limit referrals, pressure to see more patients, and career dissatisfaction. Cross-sectional mail survey. Six hundred nineteen generalist physicians (62% response rate) caring for managed care patients in 3 Minnesota health plans during 1999. Twenty-six percent of physicians reported pressure to limit referrals. In adjusted analyses, female physicians and those who were board certified acted as gatekeepers for most of their patients, received incentives based on performance reports and quality profiles, and received direct income from capitation, and were more likely than others to report this pressure (all P <.05). Sixty-two percent reported pressure to see more patients. In adjusted analyses, this pressure was more frequent among physicians in practices owned by health systems, those using physician extenders, and among physicians paid by salary with performance adjustment or those receiving at least some capitation (all P <.05). One-quarter (24%) of physicians were dissatisfied with their career in medicine. In adjusted analyses, physicians reporting pressure to limit referrals (risk ratio, 1.12; 95% confidence interval, 1.01 to 1.19) and those reporting pressure to see more patients (risk ratio, 1.37; 95% confidence interval, 1.08 to 1.66) were more likely to be dissatisfied than other physicians. Pressures to limit referrals and to see more patients are common, particularly among physicians paid based on productivity or capitation, and they are associated with career dissatisfaction. Whether future changes in practice arrangements or compensation strategies can decrease such physician-reported pressures, and ultimately improve physician satisfaction, will be an important area for future study.
Amick, Benjamin C; Lee, Hyunmi; Hogg-Johnson, Sheilah; Katz, Jeffrey N; Brouwer, Sandra; Franche, Renée-Louise; Bültmann, Ute
2017-09-01
Purpose Organizational-level policies and practices that promote safety leadership and practices, disability management and ergonomic policies and practices are considered key contextual determinants of return to work. Our objective was to examine the role of worker-reported organizational policies and practices (OPPs) in return to work (RTW) and work role functioning (WRF) and the mediating role of pain self-efficacy and work accommodation. Methods A worker cohort (n = 577) in Ontario, Canada was followed at 1, 6 and 12 months post injury. Both RTW (yes/no) and WRF (WLQ-16) status (3 levels) were measured. OPPs were measured (high vs. low) at 1 month post-injury. Pain self-efficacy (PSE) and work accommodation (WA) were included in mediation analyses. Results OPPs predicted RTW at 6 months (adjusted OR 1.77; 95 % CI 1.07-2.93) and 12 months (adjusted OR 2.07; 95 % CI 1.18-3.62). OPPs predicted WRF at 6 months, but only the transition from working with limitations to working without limitations (adjusted OR 3.21; 95 % CI 1.92-5.39). At 12 months, OPPs predicted both the transition from not working to working with and without limitations and from not working or working with limitations to working without limitations (adjusted OR 2.13; 95 % CI 1.37-3.30). Offers of WA mediated the relationship between OPPs and both RTW and WRF at 6 months follow-up. PSE mediated the relationship between OPPs and RTW and WRF at 6 months. At 12 months neither mediated the relationship. Conclusions The findings support worker-reported OPPs as key determinants of both RTW and WRF. These results point to the importance of WA and PSE in both RTW and WRF at 6 months.
Gewandter, Jennifer S.; Dale, William; Magnuson, Allison; Pandya, Chintan; Heckler, Charles E.; Lemelman, Tatyana; Roussel, Breton; Ifthikhar, Rafa; Dolan, James; Noyes, Katia; Mohile, Supriya G.
2015-01-01
Objective In older patients with cancer, we aimed to investigate associations between a patient-reported outcome measure for sarcopenia (SarcoPRO) and the Short Physical Performance Battery (SPPB), self-reported falls, and limitations in instrumental activities of daily living (IADLs). Materials and Methods Assessments were conducted as part of the initial evaluation of older, often frail, patients with cancer seen in the Specialized Oncology Care and Research in the Elderly (SOCARE) clinic. Univariate associations were evaluated using Spearman’s correlation and Wilcoxon sign ranked tests. Logistic regressions were used to identify associations of clinical factors and SarcoPRO scores or SPPB scores with falls and IADL limitations. Results In total, 174 older patients with cancer were evaluated. A moderate correlation was found between the SarcoPRO and the SPPB (ρ = 0.62). After adjusting for multiple clinical factors, neither the SarcoPRO nor the SPPB were associated with falls. In contrast, both higher SarcoPRO (i.e., worse) and lower SPPB (i.e., worse) scores were associated with limitations in IADLs (Odds ratio for one unit change in predictor: SarcoPRO: 1.06, p<0.0001; SPPB: 0.71, p = 0.003, respectively). Models using the SarcoPRO and SPPB explained similar amounts of variability in association with IADL limitations (AUC: 0.88 vs 0.87, respectively). Conclusions The SarcoPRO was moderately associated with the SPPB, an objective measure of physical performance, and was associated with limitations in IADLs. Thus, older patients with cancer who present with IADL limitations should be screened for sarcopenia. The SarcoPRO shows promise as a measure for screening as well as outcome assessment for research on sarcopenia. PMID:26365897
NASA Astrophysics Data System (ADS)
Surawathanawises, Krissada
Separation and concentration of nanoscale species play an important role in various fields such as biotechnology, nanotechnology and environmental science. Inevitably, the separation efficiency strongly affects the quality of downstream detections or productions. Innovations in materials science that can separate bionanoparticles efficiently and do not require complex setups, reagents or external fields are highly demanded. This work focuses on developing new materials for the affinity separation of bio-nanoparticles such as viruses or macromolecules from a complex mixture, such as whole blood. To enhance the interaction between target nanoparticles and the capture bed, methods to produce porous matrices with a uniform pore size matching the dimension of targets are studied. Furthermore, regarding viral separation from whole blood, macroporous materials are further patterned into microarrays to allow multiscale separation. Considering the needs in resource-limited settings, these materials are integrated with microfluidic technologies to reduce the volume of samples and reagents, simplify operating processes, and enable the use of inexpensive and portable components. Beyond the application of viral separation as demonstrated in the work, the fundamental study of macroporous material formation and transport in these materials also shed light to the separation of many other nanospecies in multiscale materials. Specifically, two macroporous materials, based on template synthesis, are created in this work. The first type employs porous anodic aluminum oxide (AAO) films as the template to create hexagonal arrays of nanoposts. However, pore sizes and interpore distances (cell size) of ordered porous AAO films are limited by the conventional fabrication process. Moreover, the process usually yields defective pore morphologies and large pore and cell size distributions. To overcome these limitations, a patterning method using nanobead indentation on aluminum substrate prior to anodization is evaluated to control the growth of AAO. Together with controlled anodizing voltages and electrolytic concentrations, AAO pore and cell sizes are shown to be tunable and controllable with narrow size distributions within submicron range. A high degree of order of AAO pore arrangement is also demonstrated. In addition, overall anodization becomes more time-efficient and stable at high anodizing voltages. Secondly, a three-dimensional (3D) assembly of microbeads is used as a template to fabricate a spherical pore network with small interconnected openings. After depositing and drying a suspension containing both micro- and nanobeads, the microbeads assemble into a 3D close-packed structure while the nanobeads fill the interstitial space. When the nanobeads are melted and microbeads are removed, a spherical pore matrix then form with small interconnected openings. Such the opening size is in submicron range can be adjusted depending on the size of microbead. The advantages of the two macroporous materials are not only controllable and tunable pore size, but also high surface-to-volume ratio due to the nanoscale features. With a ratio on the order of ~1 microm-1, the porous materials provide a significantly large binding surface. Computational and experimental results reveal that porous materials with a pore size matching the nanoparticle size are suitable for their capture. Separation of human immunodeficiency virus (HIV) is used as a model and capture yields of ~99 % and ~80 % are achieved in the nanopost structure and spherical pore network, respectively, after treated with a functional chemistry. Hence, the properties of these two macroporous materials are suitable as a size-exclusion and affinity separation for viral particles. To further explore multiscale separation, i.e. capturing viruses from whole blood, micropatterned arrays of macroporous materials have been designed. In this design, a microscale gap allows the passage of microparticles such as blood cells, and the nanoscale pores promote permeation for affinity capture of bionanoparticles. Consequently, particles with a size difference of 3--4 orders of magnitude can be separated in a simple flow-through process. Computational analyses are employed to study the effect of micropattern shape and layout. A half-ring pattern is shown to reduce flow resistance and promote fluid permeation compared to a circular pattern. In the experiment, the micropatterned porous arrays yield around 4 times higher viral capture from whole blood compared with a micropatterned solid array. The micropatterned porous devices are capable of handling a large volume of fluid sample without clogging by cells. Therefore they can be used for nanoparticle concentration. Our study also indicates that the layout of micropatterns can be adjusted to improve the capture yield. For example, an increase in pattern radius, or a decrease in gap distance between each post and in width of half ring will enhance fluid permeation in the porous structure. When combined with downstream detection, these materials integrated into microfluidic platforms can be created as point-of-care diagnostics, as well as other applications for particle separation and analysis. (Abstract shortened by UMI.).
Kascholke, Christian; Hendrikx, Stephan; Flath, Tobias; Kuzmenka, Dzmitry; Dörfler, Hans-Martin; Schumann, Dirk; Gressenbuch, Mathias; Schulze, F Peter; Schulz-Siegmund, Michaela; Hacker, Michael C
2017-11-01
Biodegradability is a crucial characteristic to improve the clinical potential of sol-gel-derived glass materials. To this end, a set of degradable organic/inorganic class II hybrids from a tetraethoxysilane(TEOS)-derived silica sol and oligovalent cross-linker oligomers containing oligo(d,l-lactide) domains was developed and characterized. A series of 18 oligomers (Mn: 1100-3200Da) with different degrees of ethoxylation and varying length of oligoester units was established and chemical composition was determined. Applicability of an established indirect rapid prototyping method enabled fabrication of a total of 85 different hybrid scaffold formulations from 3-isocyanatopropyltriethoxysilane-functionalized macromers. In vitro degradation was analyzed over 12months and a continuous linear weight loss (0.2-0.5wt%/d) combined with only moderate material swelling was detected which was controlled by oligo(lactide) content and matrix hydrophilicity. Compressive strength (2-30MPa) and compressive modulus (44-716MPa) were determined and total content, oligo(ethylene oxide) content, oligo(lactide) content and molecular weight of the oligomeric cross-linkers as well as material porosity were identified as the main factors determining hybrid mechanics. Cytocompatibility was assessed by cell culture experiments with human adipose tissue-derived stem cells (hASC). Cell migration into the entire scaffold pore network was indicated and continuous proliferation over 14days was found. ALP activity linearly increased over 2weeks indicating osteogenic differentiation. The presented glass-based hybrid concept with precisely adjustable material properties holds promise for regenerative purposes. Adaption of degradation kinetics toward physiological relevance is still an unmet challenge of (bio-)glass engineering. We therefore present a glass-derived hybrid material with adjustable degradation. A flexible design concept based on degradable multi-armed oligomers was combined with an established indirect rapid prototyping method to produce a systematic set of porous sol-gel-derived class II hybrid scaffolds. Mechanical properties in the range of cancellous bone were narrowly controlled by hybrid composition. The oligoester introduction resulted in significantly increased compressive moduli. Cytocompatible hybrids degraded in physiologically relevant time frames and a promising linear and controllable weight loss profile was found. To our knowledge, our degradation study represents the most extensive long-term investigation of sol-gel-derived class II hybrids. Due to the broad adjustability of material properties, our concept offers potential for engineering of biodegradable hybrid materials for versatile applications. Copyright © 2017. Published by Elsevier Ltd.
ERIC Educational Resources Information Center
Ohio State Univ., Columbus. National Center for Research in Vocational Education.
This course, adapted from military curriculum materials for vocational and technical education, teaches students to restore diesel engine performance to the manufacturer's specifications through troubleshooting and analyzing diesel engine fuel systems and to make minor and major adjustments to those components that directly affect engine…
ERIC Educational Resources Information Center
Matuk, Camillia F.; Linn, Marcia C.; Eylon, Bat-Sheva
2015-01-01
Teachers' involvement in curriculum design is essential for sustaining the relevance of technology-enhanced learning materials. Customizing--making small adjustments to tailor given materials to particular situations and settings--is one design activity in which busy teachers can feasibly engage. Research indicates that customizations based…
THE DEVELOPMENT OF INSTRUCTIONAL MATERIALS PERTAINING TO RACE AND CULTURE IN AMERICAN LIFE.
ERIC Educational Resources Information Center
GIBSON, JOHN S.; KVARACEUS, WILLIAM C.
THIS CURRICULUM DEVELOPMENT PROJECT WAS CONDUCTED TO ADJUST ELEMENTARY INSTRUCTIONAL PROGRAMS TO INCLUDE INFORMATION AND CONCEPTS ABOUT RACIAL-CULTURAL DIVERSITY IN AMERICA, INCLUDING THE LIFE ON THE AMERICAN NEGRO. ITS PRINCIPAL EMPHASIS WAS ON LAYING THE GROUNDWORK FOR PREPARING INSTRUCTIONAL MATERIALS IN THIS AREA OF HUMAN RELATIONS.…
Recent advances on smart TiO2 nanotube platforms for sustainable drug delivery applications.
Wang, Qun; Huang, Jian-Ying; Li, Hua-Qiong; Zhao, Allan Zi-Jian; Wang, Yi; Zhang, Ke-Qin; Sun, Hong-Tao; Lai, Yue-Kun
To address the limitations of traditional drug delivery, TiO 2 nanotubes (TNTs) are recognized as a promising material for localized drug delivery systems. With regard to the excellent biocompatibility and physicochemical properties, TNTs prepared by a facile electrochemical anodizing process have been used to fabricate new drug-releasing implants for localized drug delivery. This review discusses the development of TNTs applied in localized drug delivery systems, focusing on several approaches to control drug release, including the regulation of the dimensions of TNTs, modification of internal chemical characteristics, adjusting pore openings by biopolymer coatings, and employing polymeric micelles as drug nanocarriers. Furthermore, rational strategies on external conditions-triggered stimuli-responsive drug release for localized drug delivery systems are highlighted. Finally, the review concludes with the recent advances on TNTs for controlled drug delivery and corresponding prospects in the future.
NASA Astrophysics Data System (ADS)
Hennig, Jan-Simon; Barr, Bryan W.; Bell, Angus S.; Cunningham, William; Danilishin, Stefan L.; Dupej, Peter; Gräf, Christian; Hough, James; Huttner, Sabina H.; Jones, Russell; Leavey, Sean S.; Pascucci, Daniela; Sinclair, Martin; Sorazu, Borja; Spencer, Andrew; Steinlechner, Sebastian; Strain, Kenneth A.; Wright, Jennifer; Zhang, Teng; Hild, Stefan
2017-12-01
Low-mass suspension systems with high-Q pendulum stages are used to enable quantum radiation pressure noise limited experiments. Utilizing multiple pendulum stages with vertical blade springs and materials with high-quality factors provides attenuation of seismic and thermal noise; however, damping of these high-Q pendulum systems in multiple degrees of freedom is essential for practical implementation. Viscous damping such as eddy-current damping can be employed, but it introduces displacement noise from force noise due to thermal fluctuations in the damping system. In this paper we demonstrate a passive damping system with adjustable damping strength as a solution for this problem that can be used for low-mass suspension systems without adding additional displacement noise in science mode. We show a reduction of the damping factor by a factor of 8 on a test suspension and provide a general optimization for this system.
Recent advances on smart TiO2 nanotube platforms for sustainable drug delivery applications
Wang, Qun; Huang, Jian-Ying; Li, Hua-Qiong; Zhao, Allan Zi-Jian; Wang, Yi; Zhang, Ke-Qin; Sun, Hong-Tao; Lai, Yue-Kun
2017-01-01
To address the limitations of traditional drug delivery, TiO2 nanotubes (TNTs) are recognized as a promising material for localized drug delivery systems. With regard to the excellent biocompatibility and physicochemical properties, TNTs prepared by a facile electrochemical anodizing process have been used to fabricate new drug-releasing implants for localized drug delivery. This review discusses the development of TNTs applied in localized drug delivery systems, focusing on several approaches to control drug release, including the regulation of the dimensions of TNTs, modification of internal chemical characteristics, adjusting pore openings by biopolymer coatings, and employing polymeric micelles as drug nanocarriers. Furthermore, rational strategies on external conditions-triggered stimuli-responsive drug release for localized drug delivery systems are highlighted. Finally, the review concludes with the recent advances on TNTs for controlled drug delivery and corresponding prospects in the future. PMID:28053530
Simple predictions of maximum transport rate in unsaturated soil and rock
Nimmo, John R.
2007-01-01
In contrast with the extreme variability expected for water and contaminant fluxes in the unsaturated zone, evidence from 64 field tests of preferential flow indicates that the maximum transport speed Vmax, adjusted for episodicity of infiltration, deviates little from a geometric mean of 13 m/d. A model based on constant‐speed travel during infiltration pulses of actual or estimated duration can predict Vmax with approximate order‐of‐magnitude accuracy, irrespective of medium or travel distance, thereby facilitating such problems as the prediction of worst‐case contaminant traveltimes. The lesser variability suggests that preferential flow is subject to rate‐limiting mechanisms analogous to those that impose a terminal velocity on objects in free fall and to rate‐compensating mechanisms analogous to Le Chatlier's principle. A critical feature allowing such mechanisms to dominate may be the presence of interfacial boundaries confined by neither solid material nor capillary forces.
pH Control on the Sequential Uptake and Release of Organic Cations by Cucurbit[7]uril.
Mikulu, Lukas; Michalicova, Romana; Iglesias, Vivian; Yawer, Mirza A; Kaifer, Angel E; Lubal, Premysl; Sindelar, Vladimir
2017-02-16
Cucurbit[7]uril (CB7) is a macrocycle with the ability to form the most stable supramolecular complexes in water ever reported for an artificial receptor. Its use for the design of advanced functional materials is, however, very limited because there is no example of a fully reversible CB7 based supramolecular complex enabling repetitious dissociation/association controlled by external stimuli. We report the synthesis of a new ferrocene amino acid that forms with CB7 a 1:1 inclusion complex that is stable in submicromolar concentration at low pH but dissociates at high pH. This reversible process was used for the sequential uptake and release of bispyridinium and antraquinone guests by CB7, which is controlled by adjusting the pH of the solution. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Calcium phosphate coating on magnesium alloy for modification of degradation behavior
NASA Astrophysics Data System (ADS)
Cui, Fu-zhai; Yang, Jing-xin; Jiao, Yan-peng; Yin, Qing-shui; Zhang, Yu; Lee, In-Seop
2008-06-01
Magnesium alloy has similar mechanical properties with natural bone, but its high susceptibility to corrosion has limited its application in orthopedics. In this study, a calcium phosphate coating is formed on magnesium alloy (AZ31) to control its degradation rate and enhance its bioactivity and bone inductivity. Samples of AZ31 plate were placed in the supersaturated calcification solution prepared with Ca(NO3)2, NaH2PO4 and NaHCO3, then the calcium phosphate coating formed. Through adjusting the immersion time, the thickness of uniform coatings can be changed from 10 to 20 μm. The composition, phase structure and morphology of the coatings were investigated. Bonding strength of the coatings and substrate was 2-4 MPa in this study. The coatings significantly decrease degradation rate of the original Mg alloy, indicating that the Mg alloy with calcium phosphate coating is a promising degradable bone material.
Feedback control in deep drawing based on experimental datasets
NASA Astrophysics Data System (ADS)
Fischer, P.; Heingärtner, J.; Aichholzer, W.; Hortig, D.; Hora, P.
2017-09-01
In large-scale production of deep drawing parts, like in automotive industry, the effects of scattering material properties as well as warming of the tools have a significant impact on the drawing result. In the scope of the work, an approach is presented to minimize the influence of these effects on part quality by optically measuring the draw-in of each part and adjusting the settings of the press to keep the strain distribution, which is represented by the draw-in, inside a certain limit. For the design of the control algorithm, a design of experiments for in-line tests is used to quantify the influence of the blank holder force as well as the force distribution on the draw-in. The results of this experimental dataset are used to model the process behavior. Based on this model, a feedback control loop is designed. Finally, the performance of the control algorithm is validated in the production line.
Handbook for Rural Students: Finding Employment and Adjusting to Urban Areas. Revised Edition.
ERIC Educational Resources Information Center
Vaughn, D. Lanette; Vaughn, Paul R.
Designed to help rural students find employment and adjust to life in urban areas, the handbook provides basic information in six subject areas. Part I focuses on getting to know yourself by assessing past activities, preferences, abilities, personality, limitations, and values. Part II explores aspects of jobs and careers: being career oriented,…
ERIC Educational Resources Information Center
Mokua, Rodgers Nyandieka
2012-01-01
The literature on international students from Africa, and particularly Kenya, is very limited despite the significant number of Kenyan international students attending colleges and universities in the United States. Therefore, the intent of this study was to examine the adjustment problems of Kenyan international students in the United States. The…
Evaluation of a New Mean Scaled and Moment Adjusted Test Statistic for SEM
ERIC Educational Resources Information Center
Tong, Xiaoxiao; Bentler, Peter M.
2013-01-01
Recently a new mean scaled and skewness adjusted test statistic was developed for evaluating structural equation models in small samples and with potentially nonnormal data, but this statistic has received only limited evaluation. The performance of this statistic is compared to normal theory maximum likelihood and 2 well-known robust test…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-04
... Framework Adjustment 2 to the Atlantic Herring Fishery Management Plan (Framework 2) and the 2013-2015... New England Fishery Management Council (Council) to split annual catch limits seasonally for the four Atlantic herring management areas, and the carryover of unharvested catch, up to 10 percent for each area's...
From Slogan to Anathema: Historical Representations of Life Adjustment Education
ERIC Educational Resources Information Center
Wraga, William G.
2010-01-01
From a slogan that, from 1945 to 1954, had limited significance in education practice and, from the 1950s through the 1970s, had a small place in education histories, since 1980 life adjustment education has become, for historians, an anathema representative of the worst reform impulses in American education. By interpreting life adjustment…
Code of Federal Regulations, 2010 CFR
2010-04-01
... recovery of the subsequent overpayment. In making any determination or decision under this section... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Waiver of adjustment or recovery-countable... Employees' Benefits SOCIAL SECURITY ADMINISTRATION SUPPLEMENTAL SECURITY INCOME FOR THE AGED, BLIND, AND...
Composites comprising biologically-synthesized nanomaterials
Curran, Seamus; Dias, Sampath; Blau, Werner; Wang, Jun; Oremland, Ronald S; Baesman, Shaun
2013-04-30
The present disclosure describes composite materials containing a polymer material and a nanoscale material dispersed in the polymer material. The nanoscale materials may be biologically synthesized, such as tellurium nanorods synthesized by Bacillus selenitireducens. Composite materials of the present disclosure may have optical limiting properties and find use in optical limiting devices.
McCaffer, C J; Pabla, L; Watson, C
2018-04-01
The use of lasers in cholesteatoma surgery is common and well accepted. The most commonly used laser fibres are straight and non-adjustable; these have several limitations. This paper describes the use of an alternative laser fibre. This 'How I Do It' paper describes and illustrates the use of an alternative curved adjustable fibre-optic diode laser in microscopic cholesteatoma surgery. The curved, adjustable laser fibre allows accurate and atraumatic disease removal when the use of a straight laser fibre may be less effective or accurate. It reduces potential damage to delicate structures without the need for extra drilling or bone removal. It is suggested that the curved adjustable laser fibre is superior to the traditional straight fibre for cholesteatoma surgery.
Housing Improvements and Malaria Risk in Sub-Saharan Africa: A Multi-Country Analysis of Survey Data
Bottomley, Christian; Gibson, Harry; Kleinschmidt, Immo; Tatem, Andrew J.; Gething, Peter W.
2017-01-01
Background Improvements to housing may contribute to malaria control and elimination by reducing house entry by malaria vectors and thus exposure to biting. We tested the hypothesis that the odds of malaria infection are lower in modern, improved housing compared to traditional housing in sub-Saharan Africa (SSA). Methods and Findings We analysed 15 Demographic and Health Surveys (DHS) and 14 Malaria Indicator Surveys (MIS) conducted in 21 countries in SSA between 2008 and 2015 that measured malaria infection by microscopy or rapid diagnostic test (RDT). DHS/MIS surveys record whether houses are built with finished materials (e.g., metal) or rudimentary materials (e.g., thatch). This information was used to develop a binary housing quality variable where houses built using finished wall, roof, and floor materials were classified as “modern”, and all other houses were classified as “traditional”. Conditional logistic regression was used to determine the association between housing quality and prevalence of malaria infection in children aged 0–5 y, adjusting for age, gender, insecticide-treated net (ITN) use, indoor residual spraying, household wealth, and geographic cluster. Individual survey odds ratios (ORs) were combined to determine a summary OR using a random effects meta-analysis. Of 284,532 total children surveyed, 139,318 were tested for malaria infection using microscopy (n = 131,652) or RDT (n = 138,540). Within individual surveys, malaria prevalence measured by microscopy ranged from 0.4% (Madagascar 2011) to 45.5% (Burkina Faso 2010) among children living in modern houses and from 0.4% (The Gambia 2013) to 70.6% (Burkina Faso 2010) in traditional houses, and malaria prevalence measured by RDT ranged from 0.3% (Senegal 2013–2014) to 61.2% (Burkina Faso 2010) in modern houses and from 1.5% (The Gambia 2013) to 79.8% (Burkina Faso 2010) in traditional houses. Across all surveys, modern housing was associated with a 9% to 14% reduction in the odds of malaria infection (microscopy: adjusted OR 0.91, 95% CI 0.85–0.97, p = 0.003; RDT: adjusted OR 0.86, 95% CI 0.80–0.92, p < 0.001). This association was consistent regardless of ITN usage. As a comparison, the odds of malaria infection were 15% to 16% lower among ITN users versus non-users (microscopy: adjusted OR 0.84, 95% CI 0.79–0.90, p < 0.001; RDT: adjusted OR 0.85, 95% CI 0.80–0.90, p < 0.001). The main limitation of this study is that residual confounding by household wealth of the observed association between housing quality and malaria prevalence is possible, since the wealth index may not have fully captured differences in socioeconomic position; however, the use of multiple national surveys offers the advantage of a large sample size and the elimination of many biases typically associated with pooling observational data. Conclusions Housing quality is an important risk factor for malaria infection across the spectrum of malaria endemicity in SSA, with a strength of association between housing quality and malaria similar to that observed between ITN use and malaria. Improved housing should be considered a promising intervention for malaria control and elimination and long-term prevention of reintroduction. PMID:28222094
Code of Federal Regulations, 2013 CFR
2013-04-01
... take effect in a plan year if the adjusted funding target attainment percentage for the plan year is... provides rules relating to funding-based limitations on certain benefits under section 436, and the... limitations in effect immediately before the termination of a plan do not cease to apply thereafter. (B...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Industrial Sand Subcategory § 436.42 Effluent limitations guidelines representing the degree of effluent... 6.0 and water quality criteria in water quality standards approved under the Act authorize such lower pH, the pH limitation for such discharge may be adjusted downward to the pH water quality...
Internet-Based Self-Help Intervention for ICD-11 Adjustment Disorder: Preliminary Findings.
Eimontas, Jonas; Rimsaite, Zivile; Gegieckaite, Goda; Zelviene, Paulina; Kazlauskas, Evaldas
2018-06-01
Adjustment disorder is one of the most diagnosed mental disorders. However, there is a lack of studies of specialized internet-based psychosocial interventions for adjustment disorder. We aimed to analyze the outcomes of an internet-based unguided self-help psychosocial intervention BADI for adjustment disorder in a two armed randomized controlled trial with a waiting list control group. In total 284 adult participants were randomized in this study. We measured adjustment disorder as a primary outcome, and psychological well-being as a secondary outcome at pre-intervention (T1) and one month after the intervention (T2). We found medium effect size of the intervention for the completer sample on adjustment disorder symptoms. Intervention was effective for those participants who used it at least one time in 30-day period. Our results revealed the potential of unguided internet-based self-help intervention for adjustment disorder. However, high dropout rates in the study limits the generalization of the outcomes of the intervention only to completers.
Kawaguchi, Naoto; Kurata, Akira; Kido, Teruhito; Nishiyama, Yoshiko; Kido, Tomoyuki; Miyagawa, Masao; Ogimoto, Akiyoshi; Mochizuki, Teruhito
2014-01-01
The purpose of this study was to evaluate a personalized protocol with diluted contrast material (CM) for coronary computed tomography angiography (CTA). One hundred patients with suspected coronary artery disease underwent retrospective electrocardiogram-gated coronary CTA on a 256-slice multidetector-row CT scanner. In the diluted CM protocol (n=50), the optimal scan timing and CM dilution rate were determined by the timing bolus scan, with 20% CM dilution (5ml/s during 10s) being considered suitable to achieve the target arterial attenuation of 350 Hounsfield units (HU). In the body weight (BW)-adjusted protocol (n=50, 222mg iodine/kg), only the optimal scan timing was determined by the timing bolus scan. The injection rate and volume in the timing bolus scan and real scan were identical between the 2 protocols. We compared the means and variations in coronary attenuation between the 2 protocols. Coronary attenuation (mean±SD) in the diluted CM and BW-adjusted protocols was 346.1±23.9 HU and 298.8±45.2 HU, respectively. The diluted CM protocol provided significantly higher coronary attenuation and lower variance than did the BW-adjusted protocol (P<0.05, in each). The diluted CM protocol facilitates more uniform attenuation on coronary CTA in comparison with the BW-adjusted protocol.
Marital status, social capital, material conditions and self-rated health: a population-based study.
Lindström, Martin
2009-12-01
Associations between marital status and self-rated health were investigated, adjusting for material conditions and trust (social capital). The 2004 public-health survey in Skåne is a cross-sectional study. A total of 27,757 persons aged 18-80 years answered a postal questionnaire, which represents 59% of the random sample. A logistic regression model was used to investigate associations between marital status and self-rated health, adjusting for economic problems and trust. The prevalence of poor self-rated health was 28.7% among men and 33.2% among women. Older respondents, respondents born abroad, with medium/low education, low emotional support, low instrumental support, economic problems, low trust, never married and divorced had significantly higher odds ratios of poor self-rated health than their respective reference group. Low trust was significantly higher among the divorced and unmarried compared to the married/cohabitating. Adjustment for economic problems but not for trust reduced the odds ratios of poor self-rated health among the divorced, which became not significant among men. Never married and the divorced have significantly higher age-adjusted odds ratios of poor self-rated health than the married/cohabitating group. Economic problems but not trust seem to affect the association between marital status and poor self-rated health.
NASA Astrophysics Data System (ADS)
Salzman, S.; Romanofsky, H. J.; Clara, Y. I.; Giannechini, L. J.; West, Garrett J.; Lambropoulos, J. C.; Jacobs, S. D.
2013-09-01
Magnetorheological finishing (MRF) of polycrystalline, chemical-vapor-deposited (CVD) zinc sulfide (ZnS) and zinc selenide (ZnSe) can leave millimeter-size artifacts on the part surface. These pebble-like features come from the anisotropic mechanical and chemical properties of the ceramic material and from the CVD growth process itself. The resulting surface texture limits the use of MRF for polishing aspheric and other complex shapes using these important infrared (IR) ceramics. An investigation of the individual contributions of chemistry and mechanics to polishing of other polycrystalline ceramics has been employed in the past to overcome similar material anisotropy problems. The approach taken was to study the removal process for the different single-crystal orientations that comprise the ceramic, making adjustments to mechanics (polishing abrasive type and concentration) and polishing slurry chemistry (primarily pH) to equalize the removal rate for all crystal orientations. Polishing with the modified slurry was shown to prevent the development of surface texture. Here we present mechanical (microhardness testing) and chemical (acid etching) studies performed on the four single-crystal orientations of ZnS: 100, 110, 111, and 311. We found that the (111) plane is 35% to 55% harder and 30% to 40% more resistant to chemical etching than the other three planes. This relatively high degree of variation in these properties can help to explain the surface texture developed from MRF of the polycrystalline material. Theoretical calculations of microhardness, planar, and bond densities are presented and compared with the experimental data. Here surface characterization of these single-crystal orientations of ZnS for material removal and roughness with chemically modified MR fluids at various pH levels between pH 4 and pH 6 are presented for the first time.
Theoretical Limits of Energy Density in Silicon-Carbon Composite Anode Based Lithium Ion Batteries.
Dash, Ranjan; Pannala, Sreekanth
2016-06-17
Silicon (Si) is under consideration as a potential next-generation anode material for the lithium ion battery (LIB). Experimental reports of up to 40% increase in energy density of Si anode based LIBs (Si-LIBs) have been reported in literature. However, this increase in energy density is achieved when the Si-LIB is allowed to swell (volumetrically expand) more than graphite based LIB (graphite-LIB) and beyond practical limits. The volume expansion of LIB electrodes should be negligible for applications such as automotive or mobile devices. We determine the theoretical bounds of Si composition in a Si-carbon composite (SCC) based anode to maximize the volumetric energy density of a LIB by constraining the external dimensions of the anode during charging. The porosity of the SCC anode is adjusted to accommodate the volume expansion during lithiation. The calculated threshold value of Si was then used to determine the possible volumetric energy densities of LIBs with SCC anode (SCC-LIBs) and the potential improvement over graphite-LIBs. The level of improvement in volumetric and gravimetric energy density of SCC-LIBs with constrained volume is predicted to be less than 10% to ensure the battery has similar power characteristics of graphite-LIBs.
Installation and assembly device and method of using
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kolsun, G.J.
1995-12-31
The present invention relates to an installation and assembly device and method for facilitating the fitup of mating components during blind or remote installation and assembly, especially where close fitup tolerances are involved. The present invention is particularly useful for the purpose of facilitating vertical and/or radial relative positioning of a pump impeller within a mating inlet nozzle during a blind assembly wherein actual fitup cannot be observed during installation. The information within identifies just one successful application of the installation and assembly alignment device for a pump. The device, however, is not solely limited to pump assembly but canmore » be used in other cases where fitup of a sleeve inside a mating bore is required under conditions of close tolerance during a blind or remote assembly. The device is likewise not limited to circular configurations but can be used for many other shapes or configurations. Any material that can be machined and hold reasonably close tolerances can be used for the device. Also, because the sleeve position is adjusted by set screws or bolts, the concentricity can be radially biased, if required, to achieve particular alignment conditions.« less
NASA Astrophysics Data System (ADS)
Castel, J. G.; Husarek, V.
1987-06-01
The usefulness of a portable microprocessor-controlled ultrasound device for the periodic assessment of aircraft parts made of composite materials is shown. The performance of the device is demonstrated with the examples of a metallic honeycomb with a carbon-fiber skin, a phenolic honeycomb with a carbon skin, and a phenolic honeycomb with a Kevlar skin. Also considered are assessments of homogeneous carbon-fiber parts, including the study of artificial defects consisting of 1-2 mm diameter holes, and the assessment of the behavior of a carbon-titanium interface with separated zones. Advantages of the device include ease of adjustment, automated evaluation of the depth of defects, and the nearly-absolute reproducibility of adjustments.
Whittemore, Stephen Richard
2013-09-10
Imaging systems include a detector and a spatial light modulator (SLM) that is coupled so as to control image intensity at the detector based on predetermined detector limits. By iteratively adjusting SLM element values, image intensity at one or all detector elements or portions of an imaging detector can be controlled to be within limits. The SLM can be secured to the detector at a spacing such that the SLM is effectively at an image focal plane. In some applications, the SLM can be adjusted to impart visible or hidden watermarks to images or to reduce image intensity at one or a selected set of detector elements so as to reduce detector blooming
NASA Astrophysics Data System (ADS)
Wang, L.-P.; Ochoa-Rodríguez, S.; Onof, C.; Willems, P.
2015-09-01
Gauge-based radar rainfall adjustment techniques have been widely used to improve the applicability of radar rainfall estimates to large-scale hydrological modelling. However, their use for urban hydrological applications is limited as they were mostly developed based upon Gaussian approximations and therefore tend to smooth off so-called "singularities" (features of a non-Gaussian field) that can be observed in the fine-scale rainfall structure. Overlooking the singularities could be critical, given that their distribution is highly consistent with that of local extreme magnitudes. This deficiency may cause large errors in the subsequent urban hydrological modelling. To address this limitation and improve the applicability of adjustment techniques at urban scales, a method is proposed herein which incorporates a local singularity analysis into existing adjustment techniques and allows the preservation of the singularity structures throughout the adjustment process. In this paper the proposed singularity analysis is incorporated into the Bayesian merging technique and the performance of the resulting singularity-sensitive method is compared with that of the original Bayesian (non singularity-sensitive) technique and the commonly used mean field bias adjustment. This test is conducted using as case study four storm events observed in the Portobello catchment (53 km2) (Edinburgh, UK) during 2011 and for which radar estimates, dense rain gauge and sewer flow records, as well as a recently calibrated urban drainage model were available. The results suggest that, in general, the proposed singularity-sensitive method can effectively preserve the non-normality in local rainfall structure, while retaining the ability of the original adjustment techniques to generate nearly unbiased estimates. Moreover, the ability of the singularity-sensitive technique to preserve the non-normality in rainfall estimates often leads to better reproduction of the urban drainage system's dynamics, particularly of peak runoff flows.
Lovell, Karina; Bower, Peter; Gellatly, Judith; Byford, Sarah; Bee, Penny; McMillan, Dean; Arundel, Catherine; Gilbody, Simon; Gega, Lina; Hardy, Gillian; Reynolds, Shirley; Barkham, Michael; Mottram, Patricia; Lidbetter, Nicola; Pedley, Rebecca; Molle, Jo; Peckham, Emily; Knopp-Hoffer, Jasmin; Price, Owen; Connell, Janice; Heslin, Margaret; Foley, Christopher; Plummer, Faye; Roberts, Christopher
2017-06-01
Obsessive-compulsive disorder (OCD) is prevalent and without adequate treatment usually follows a chronic course. "High-intensity" cognitive-behaviour therapy (CBT) from a specialist therapist is current "best practice." However, access is difficult because of limited numbers of therapists and because of the disabling effects of OCD symptoms. There is a potential role for "low-intensity" interventions as part of a stepped care model. Low-intensity interventions (written or web-based materials with limited therapist support) can be provided remotely, which has the potential to increase access. However, current evidence concerning low-intensity interventions is insufficient. We aimed to determine the clinical effectiveness of 2 forms of low-intensity CBT prior to high-intensity CBT, in adults meeting the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) criteria for OCD. This study was approved by the National Research Ethics Service Committee North West-Lancaster (reference number 11/NW/0276). All participants provided informed consent to take part in the trial. We conducted a 3-arm, multicentre randomised controlled trial in primary- and secondary-care United Kingdom mental health services. All patients were on a waiting list for therapist-led CBT (treatment as usual). Four hundred and seventy-three eligible patients were recruited and randomised. Patients had a median age of 33 years, and 60% were female. The majority were experiencing severe OCD. Patients received 1 of 2 low-intensity interventions: computerised CBT (cCBT; web-based CBT materials and limited telephone support) through "OCFighter" or guided self-help (written CBT materials with limited telephone or face-to-face support). Primary comparisons concerned OCD symptoms, measured using the Yale-Brown Obsessive Compulsive Scale-Observer-Rated (Y-BOCS-OR) at 3, 6, and 12 months. Secondary outcomes included health-related quality of life, depression, anxiety, and functioning. At 3 months, guided self-help demonstrated modest benefits over the waiting list in reducing OCD symptoms (adjusted mean difference = -1.91, 95% CI -3.27 to -0.55). These effects did not reach a prespecified level of "clinically significant benefit." cCBT did not demonstrate significant benefit (adjusted mean difference = -0.71, 95% CI -2.12 to 0.70). At 12 months, neither guided self-help nor cCBT led to differences in OCD symptoms. Early access to low-intensity interventions led to significant reductions in uptake of high-intensity CBT over 12 months; 86% of the patients allocated to the waiting list for high-intensity CBT started treatment by the end of the trial, compared to 62% in supported cCBT and 57% in guided self-help. These reductions did not compromise longer-term patient outcomes. Data suggested small differences in satisfaction at 3 months, with patients more satisfied with guided self-help than supported cCBT. A significant issue in the interpretation of the results concerns the level of access to high-intensity CBT before the primary outcome assessment. We have demonstrated that providing low-intensity interventions does not lead to clinically significant benefits but may reduce uptake of therapist-led CBT. International Standard Randomized Controlled Trial Number (ISRCTN) Registry ISRCTN73535163.
Gellatly, Judith; Byford, Sarah; Bee, Penny; McMillan, Dean; Gilbody, Simon; Gega, Lina; Hardy, Gillian; Reynolds, Shirley; Barkham, Michael; Mottram, Patricia; Molle, Jo; Knopp-Hoffer, Jasmin; Connell, Janice; Heslin, Margaret; Foley, Christopher; Plummer, Faye
2017-01-01
Background Obsessive-compulsive disorder (OCD) is prevalent and without adequate treatment usually follows a chronic course. “High-intensity” cognitive-behaviour therapy (CBT) from a specialist therapist is current “best practice.” However, access is difficult because of limited numbers of therapists and because of the disabling effects of OCD symptoms. There is a potential role for “low-intensity” interventions as part of a stepped care model. Low-intensity interventions (written or web-based materials with limited therapist support) can be provided remotely, which has the potential to increase access. However, current evidence concerning low-intensity interventions is insufficient. We aimed to determine the clinical effectiveness of 2 forms of low-intensity CBT prior to high-intensity CBT, in adults meeting the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) criteria for OCD. Methods and findings This study was approved by the National Research Ethics Service Committee North West–Lancaster (reference number 11/NW/0276). All participants provided informed consent to take part in the trial. We conducted a 3-arm, multicentre randomised controlled trial in primary- and secondary-care United Kingdom mental health services. All patients were on a waiting list for therapist-led CBT (treatment as usual). Four hundred and seventy-three eligible patients were recruited and randomised. Patients had a median age of 33 years, and 60% were female. The majority were experiencing severe OCD. Patients received 1 of 2 low-intensity interventions: computerised CBT (cCBT; web-based CBT materials and limited telephone support) through “OCFighter” or guided self-help (written CBT materials with limited telephone or face-to-face support). Primary comparisons concerned OCD symptoms, measured using the Yale-Brown Obsessive Compulsive Scale–Observer-Rated (Y-BOCS-OR) at 3, 6, and 12 months. Secondary outcomes included health-related quality of life, depression, anxiety, and functioning. At 3 months, guided self-help demonstrated modest benefits over the waiting list in reducing OCD symptoms (adjusted mean difference = −1.91, 95% CI −3.27 to −0.55). These effects did not reach a prespecified level of “clinically significant benefit.” cCBT did not demonstrate significant benefit (adjusted mean difference = −0.71, 95% CI −2.12 to 0.70). At 12 months, neither guided self-help nor cCBT led to differences in OCD symptoms. Early access to low-intensity interventions led to significant reductions in uptake of high-intensity CBT over 12 months; 86% of the patients allocated to the waiting list for high-intensity CBT started treatment by the end of the trial, compared to 62% in supported cCBT and 57% in guided self-help. These reductions did not compromise longer-term patient outcomes. Data suggested small differences in satisfaction at 3 months, with patients more satisfied with guided self-help than supported cCBT. A significant issue in the interpretation of the results concerns the level of access to high-intensity CBT before the primary outcome assessment. Conclusions We have demonstrated that providing low-intensity interventions does not lead to clinically significant benefits but may reduce uptake of therapist-led CBT. Trial registration International Standard Randomized Controlled Trial Number (ISRCTN) Registry ISRCTN73535163. PMID:28654682
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-18
... mandated indexing of loan limits. Section 2145 (b) of the Housing and Economic Recovery Act (HERA) of 2008 requires HUD to develop a method of indexing to annually adjust Title I manufactured home loan limits. This...
Aircraft Maintenance Expert Systems.
1983-11-01
PARA 2 -104)) 44: (( JETCAL ANALYSIS SHOWS SYSTEM READS CORRECT) (REPLACE FAULTY PARTS)) 45: ((OVERTEMP EXCEEDED SERVICE LIMITS) 46: I(ENGINE CONTROL...CIRCUITS WITHIN LIMITS ON JETCAL ) (REPLACE FAULTY PARTS)) 47: (ADJUST EST AT AMPLIFIER AND CHECK TENP)) (SEND ENGINE TO HIGHER LEVEL MAINTENANCE)) 48: 2
Morphological assessment of reconstructed lowland streams in the Netherlands
NASA Astrophysics Data System (ADS)
Eekhout, Joris P. C.; Hoitink, Antonius J. F.; de Brouwer, Jan H. F.; Verdonschot, Piet F. M.
2015-07-01
Channelisation measures taken halfway the 20th century have had destructive consequences for the diversity of the ecology in the majority of the lowland streams in countries such as the Netherlands. Re-meandering is the common practice in restoring these lowland streams. Three reconstructed streams were monitored during the initial two years after construction of a new channel. The monitoring program included morphological surveys, sediment sampling, habitat pattern surveys, and discharge and water level measurements. Adjustments of the longitudinal bed profile formed the main morphological response. These adjustments were most likely caused by a lack of longitudinal connectivity of the streams as a whole, interrupting transport of sediment at locations of weirs and culverts. Bank erosion was observed only in a limited number of channel bends, and was often related to floodplain heterogeneity. Longitudinal channel bed adjustments and bank erosion were mainly caused by exogenous influences. In channel bends, the cross-sectional shape transformed from trapezoidal to the typical asymmetrical shape as found in meandering rivers. This behaviour can be attributed to an autogenous response to the prevailing flow conditions. Due to the prevailing fine sediment characteristics, bed material is readily set in motion and is being transported during the entire year. The existing design principles fail to address the initial morphological development after reconstruction. An evaluation of pre-set targets to realise water depth and flow velocity ranges shows the current procedures to be deficient. Based on this unfavourable evaluation, and the two-dimensional nature of habitat patterns needed to improve the conditions for stream organisms, we recommend to predict morphological developments as part of the design procedures for lowland stream restoration in the Netherlands.
Morphological Assessment of Reconstructed Lowland Streams in the Netherlands
NASA Astrophysics Data System (ADS)
Hoitink, T.; Eekhout, J.; de Brouwer, J.; Verdonschot, P.
2014-12-01
Channelisation measures taken halfway the 20th century have had destructive consequences for the diversity of the ecology in the majority of the lowland streams in countries such as the Netherlands. Re-meandering is the common practice in restoring these lowland streams. Three lowland streams were monitored during the initial two years after construction of a new channel. The monitoring program included morphological surveys, sediment sampling, habitat pattern surveys, and discharge and water level measurements. Adjustments of the longitudinal bed profile formed the main morphological response. These adjustments were most likely caused by a lack of longitudinal connectivity of the streams as a whole, interrupting transport of sediment at locations of weirs and culverts. Bank erosion was observed only in a limited number of channel bends, and was often related to floodplain heterogeneity. Longitudinal channel bed adjustments and bank erosion were mainly caused by exogenous influences. In channel bends, the cross-sectional shape transformed from trapezoidal to the typical asymmetrical shape as found in meandering rivers. This behaviour can be attributed to an autogenous response to the prevailing flow conditions. Due to the prevailing fine sediment characteristics, bed material is readily set in motion and is being transported during the entire year. The existing design principles fail to address the initial morphological development after reconstruction. An evaluation of pre-set targets to realize water depth and flow velocity ranges shows the current procedures to be deficient. Based on this unfavourable evaluation, and the two-dimensional nature of habitat patterns needed to improve the conditions for stream organisms, we recommend to predict morphological developments as part of the design procedures for lowland stream restoration in the Netherlands.
Coffee consumption is inversely associated with type 2 diabetes in Chinese
Lin, Wen-Yuan; Pi-Sunyer, F. Xaiver; Chen, Ching-Chu; Davidson, Lance E.; Liu, Chiu-Shong; Li, Tsai-Chung; Wu, Mei-Fong; Li, Chia-Ing; Chen, Walter; Lin, Cheng-Chieh
2011-01-01
Background Coffee consumption has been shown to be inversely associated to type 2 diabetes mellitus (T2DM), but evidence in Chinese populations is limited. We investigated the relationship between coffee consumption and T2DM in a population-based cohort of middle-aged Chinese. Materials and Methods We studied 2,332 subjects who participated in the Taichung Community Health Study in Taiwan in 2004. The relationships between coffee consumption, T2DM and fasting glucose were assessed. Results The prevalence of T2DM was 14.0% and 10.4% in men and women. After adjustment for age, body mass index, blood pressure, smoking, alcohol drinking, betel nut chewing, physical activity, income, education level, fat%, protein%, carbohydrate%, and magnesium, coffee intake was inversely associated with T2DM. Habitual coffee drinkers had 38–46% lower risk of T2DM than non-drinkers. Compared to non-drinkers, the adjusted odds ratios (ORs) for T2DM according to subjects with habitual coffee consumption (<1, 1–6, ≥ 7 times per week) were 0.77(0.52–1.13), 0.46(0.28–0.76), and 0.37(0.16–0.83), respectively. The decreasing ORs indicate a dose-response effect of coffee consumption on the likelihood of having T2DM (p < 0.001). A similar relationship was also evident in newly-diagnosed T2DM (p < 0.05). The adjusted mean fasting glucose levels gradually decreased as the frequency of coffee consumption increased (p < 0.05). Conclusions Coffee intake is inversely associated with T2DM in Chinese. Coffee may be a protective agent for T2DM in Chinese. PMID:21226707
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Xiangpeng; Schipper, Matthew; Department of Biostatistics, the University of Michigan, Ann Arbor, Michigan
Purpose: This study compared treatment outcomes of stereotactic body radiation therapy (SBRT) with those of surgery in stage I non-small cell lung cancer (NSCLC). Methods and Materials: Eligible studies of SBRT and surgery were retrieved through extensive searches of the PubMed, Medline, Embase, and Cochrane library databases from 2000 to 2012. Original English publications of stage I NSCLC with adequate sample sizes and adequate SBRT doses were included. A multivariate random effects model was used to perform a meta-analysis to compare survival between treatments while adjusting for differences in patient characteristics. Results: Forty SBRT studies (4850 patients) and 23 surgerymore » studies (7071 patients) published in the same period were eligible. The median age and follow-up duration were 74 years and 28.0 months for SBRT patients and 66 years and 37 months for surgery patients, respectively. The mean unadjusted overall survival rates at 1, 3, and 5 years with SBRT were 83.4%, 56.6%, and 41.2% compared to 92.5%, 77.9%, and 66.1% with lobectomy and 93.2%, 80.7%, and 71.7% with limited lung resections. In SBRT studies, overall survival improved with increasing proportion of operable patients. After we adjusted for proportion of operable patients and age, SBRT and surgery had similar estimated overall and disease-free survival. Conclusions: Patients treated with SBRT differ substantially from patients treated with surgery in age and operability. After adjustment for these differences, OS and DFS do not differ significantly between SBRT and surgery in patients with operable stage I NSCLC. A randomized prospective trial is warranted to compare the efficacy of SBRT and surgery.« less
Statistics, Adjusted Statistics, and Maladjusted Statistics.
Kaufman, Jay S
2017-05-01
Statistical adjustment is a ubiquitous practice in all quantitative fields that is meant to correct for improprieties or limitations in observed data, to remove the influence of nuisance variables or to turn observed correlations into causal inferences. These adjustments proceed by reporting not what was observed in the real world, but instead modeling what would have been observed in an imaginary world in which specific nuisances and improprieties are absent. These techniques are powerful and useful inferential tools, but their application can be hazardous or deleterious if consumers of the adjusted results mistake the imaginary world of models for the real world of data. Adjustments require decisions about which factors are of primary interest and which are imagined away, and yet many adjusted results are presented without any explanation or justification for these decisions. Adjustments can be harmful if poorly motivated, and are frequently misinterpreted in the media's reporting of scientific studies. Adjustment procedures have become so routinized that many scientists and readers lose the habit of relating the reported findings back to the real world in which we live.
A FEM-based method to determine the complex material properties of piezoelectric disks.
Pérez, N; Carbonari, R C; Andrade, M A B; Buiochi, F; Adamowski, J C
2014-08-01
Numerical simulations allow modeling piezoelectric devices and ultrasonic transducers. However, the accuracy in the results is limited by the precise knowledge of the elastic, dielectric and piezoelectric properties of the piezoelectric material. To introduce the energy losses, these properties can be represented by complex numbers, where the real part of the model essentially determines the resonance frequencies and the imaginary part determines the amplitude of each resonant mode. In this work, a method based on the Finite Element Method (FEM) is modified to obtain the imaginary material properties of piezoelectric disks. The material properties are determined from the electrical impedance curve of the disk, which is measured by an impedance analyzer. The method consists in obtaining the material properties that minimize the error between experimental and numerical impedance curves over a wide range of frequencies. The proposed methodology starts with a sensitivity analysis of each parameter, determining the influence of each parameter over a set of resonant modes. Sensitivity results are used to implement a preliminary algorithm approaching the solution in order to avoid the search to be trapped into a local minimum. The method is applied to determine the material properties of a Pz27 disk sample from Ferroperm. The obtained properties are used to calculate the electrical impedance curve of the disk with a Finite Element algorithm, which is compared with the experimental electrical impedance curve. Additionally, the results were validated by comparing the numerical displacement profile with the displacements measured by a laser Doppler vibrometer. The comparison between the numerical and experimental results shows excellent agreement for both electrical impedance curve and for the displacement profile over the disk surface. The agreement between numerical and experimental displacement profiles shows that, although only the electrical impedance curve is considered in the adjustment procedure, the obtained material properties allow simulating the displacement amplitude accurately. Copyright © 2014 Elsevier B.V. All rights reserved.
Functional limitation and chronic diseases are associated with food insecurity among U.S. adults.
Venci, Brittany J; Lee, Seung-Yeon
2018-03-01
This study examined associations of functional limitation due to any health problems and six chronic diseases (arthritis, diabetes, coronary heart disease, heart attack, hypertension, and stroke) with food security among U.S. adults. The 2011 National Health Interview Survey data for 30,010 adults (≥18 years) were used. Adults were categorized into food secure, low food secure, or very low food secure. Multivariable logistic regressions were used to estimate adjusted odds ratio (OR) and 95% confidence interval (CI) for having functional limitation and chronic diseases while adjusting for sociodemographic and lifestyle factors. The prevalence of functional limitation and the chronic diseases were higher in low-food-secure and very low-food-secure than food-secure adults. The adjusted ORs were significant in both low food secure and very low food secure, respectively, for functional limitation (OR: 1.87; 95% CI: 1.63, 2.14), (OR: 2.20; 95% CI: 1.91, 2.52), inflammatory diseases or joint/muscular pain (OR: 1.42; 95% CI: 1.21, 1.68), (OR: 1.74; 95% CI: 1.49, 2.04), diabetes (OR: 1.26; 95% CI: 1.06, 1.51), (OR: 1.23; 95% CI: 1.02, 1.48), and hypertension (OR: 1.18; 95% CI: 1.04, 1.35), (OR: 1.42; 95% CI: 1.22, 1.65) when compared with food-secure adults. Findings indicate that food insecurity is associated with functional limitation and chronic diseases, whereas directionality is unknown. Besides the traditional food assistance program for food-insecure populations, interventions to prevent or manage chronic diseases may be necessary to help them reduce the risk of the diseases and manage their conditions. Copyright © 2018 Elsevier Inc. All rights reserved.
De Rekeneire, Nathalie; Resnick, Helaine E; Schwartz, Ann V; Shorr, Ronald I; Kuller, Lewis H; Simonsick, Eleanor M; Vellas, Bruno; Harris, Tamara B
2003-12-01
The aim of this study was to examine the role of comorbid conditions and body composition in the association between diabetes and subclinical functional limitation, an indication of early functional decline, in well-functioning older individuals. This was a cross-sectional analysis of 3,075 well-functioning black and white men and women aged 70-79 years, enrolled in the Health, Aging, and Body Composition study. Diabetes was defined by self-report and/or hypoglycemic medication use or fasting glucose >/=126 mg/dl. Subclinical functional limitation was defined using self-report of capacity and objective performance measures. Comorbid conditions were identified by self-reported diagnoses, medication use, and clinical measures. Body composition measures included anthropometry and total fat (dual X-ray absorptiometry). Of 2,926 participants, 1,252 (42.8%) had subclinical functional limitation at baseline. Among 2,370 individuals without diabetes, 40% had subclinical functional limitation, whereas the prevalence was 53% among the 556 diabetic participants with an age/sex/race-adjusted odds ratio (OR) 1.70 (95% CI 1.40-2.06). This association remained significant when adjusted for body composition measures (OR 1.54 [1.26-1.88]), diabetes-related comorbidities, and other potential confounders (OR 1.40 [1.14-1.73]). In the fully adjusted model, consideration of HbA(1c) (< or >/=7%) and diabetes duration showed that poor glycemic control in diabetic individuals explained the association with subclinical functional limitation. In a well-functioning older population, diabetes is associated with early indicators of functional decline, even after accounting for body composition and diabetes-related comorbidities. Poor glycemic control contributes to this relationship. Whether improvement in glycemic control in older people with diabetes would change this association should be tested.
Warzoha, Ronald J; Fleischer, Amy S
2014-08-13
Solid-liquid phase change materials (PCMs) are attractive candidates for thermal energy storage and electronics cooling applications but have limited applicability in state-of-the-art technologies due to their low intrinsic thermal conductivities. Recent efforts to incorporate graphene and multilayer graphene into PCMs have led to the development of thermal energy storage materials with remarkable values of bulk thermal conductivity. However, the full potential of graphene as a filler material for the thermal enhancement of PCMs remains unrealized, largely due to an incomplete understanding of the physical mechanisms that govern thermal transport within graphene-based nanocomposites. In this work, we show that the number of graphene layers (n) within an individual graphene nanoparticle has a significant effect on the bulk thermal conductivity of an organic PCM. Results indicate that the bulk thermal conductivity of PCMs can be tuned by over an order of magnitude simply by adjusting the number of graphene layers (n) from n = 3 to 44. Using scanning electron microscopy in tandem with nanoscale analytical techniques, the physical mechanisms that govern heat flow within a graphene nanocomposite PCM are found to be nearly independent of the intrinsic thermal conductivity of the graphene nanoparticle itself and are instead found to be dependent on the mechanical compliance of the graphene nanoparticles. These findings are critical for the design and development of PCMs that are capable of cooling next-generation electronics and storing heat effectively in medium-to-large-scale energy systems, including solar-thermal power plants and building heating and cooling systems.
[Fabrication and Performance Study of Polydimethylsiloxane Intraocular Lens].
Du, Qiuyue; Yu, Yueqing
2016-10-01
To simplify the production process of intraocular lens(IOL)and to solve the problem of lacking adjustable ability,we proposed a novel soft IOL with large-scale adjustable ability and rigid haptics based on heat-assisted method,and gravity-assisted method.Polydimethylsiloxane(PDMS)and rigid material--polymethyl methacrylate(PMMA)were used as the materials for fabricating optical lens(PDMS)and haptics(PDMS and PMMA)through changing the weight ratio of the solution.A lens-smartphone microscopy system was established to replace the traditional digital microscopy to measure the tiny displacements and shape changes.The PDMS lens has excellent optical property through an experiment in which the maximum optical power was around 273.2D.Experimental results indicated that the maximum optical power of PMMA IOL was 129.3D,and that in PDMS IOL,however,was only 56.0D.Thus,the rigid PMMA-IOL has a larger adjustable range.The production process of PDMS was mold-free,rapid,real-time,and highly repeatable and there was no need for a rigorous experimental environment either.This creative processing technology reduced the manufacturing steps from which an optical lens with high transmittance and high resolution,as well as hatics with accurate dimensions,were obtained.The rigidity of haptics affected more intensely than other factors did for improving the pre-displacement and changing the appearance of PDMS lens.Even though the rigidity of PMMA haptics is large enough for accommodating,there are many drawbacks during manufacturing.It is unavailable to rapid fabricate IOL using PMMA.Thus,further work will be required to alter the weight ratio of PDMS material,increase the rigidity,and enhance the adjustable ability of PDMS IOL.
One-dimensional photonic crystal optical limiter.
Soon, Boon Yi; Haus, Joseph; Scalora, Michael; Sibilia, Concita
2003-08-25
We explore a new passive optical limiter design using transverse modulation instability in the one-dimensional photonic crystal (PC) using x(3) materials. The performance of PC optical limiters strongly depends on the choice of the materials and the geometry and it improves as the duration of the incident pulse is extended. PC optical limiter performance is compared with that of a device made from homogeneous material. We identify three criteria for benchmarking the PC optical limiter. We also include a discussion of the advantages and disadvantages of PC optical limiters for real world applications.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-28
... Adjustment if Access Area Yellowtail Flounder (YTF) TAC Is Attained Under the Northeast Multispecies FMP, 10..., Delmarva, and NLAA; and limited access DAS vessels will be compensated 0.10 DAS per DAS fished during... one that would result in a 10-percent shift in baseline effort from the Mid-Atlantic during June 15...
Laura P. Leites; Gerald E. Rehfeldt; Andrew P. Robinson; Nicholas L. Crookston; Barry Jaquish
2012-01-01
Under projected changes in global climate, the growth and survival of existing forests will depend on their ability to adjust physiologically in response to environmental change. Quantifying their capacity to adjust and whether the response is species- or population-specific is important to guide forest management strategies. New analyses of historic provenance tests...
Code of Federal Regulations, 2010 CFR
2010-04-01
... capital expenditures and are adjustments to basis under section 1016(a). A partner must combine his... appropriate adjustment to the basis of the relevant partnership property under section 1016. For purposes of... he elects to deduct. A allocates $10,000 of his $25,000 limitation to his distributive share of the...
Code of Federal Regulations, 2011 CFR
2011-04-01
... capital expenditures and are adjustments to basis under section 1016(a). A partner must combine his... appropriate adjustment to the basis of the relevant partnership property under section 1016. For purposes of... he elects to deduct. A allocates $10,000 of his $25,000 limitation to his distributive share of the...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-09
... fertilizers) in solids. quantities >3,000 L (793 gallons) in a single packaging. 5.2 Any quantity of Organic Any quantity of Organic None. peroxide, Type B, liquid peroxide, Type B, liquid or solid, temperature... ammonium nitrate fertilizers; (13) Division 6.1 Packing Group I toxic materials; (14) Division 6.2...
A Multiple-range Self-balancing Thermocouple Potentiometer
NASA Technical Reports Server (NTRS)
Warshawsky, I; Estrin, M
1951-01-01
A multiple-range potentiometer circuit is described that provides automatic measurement of temperatures or temperature differences with any one of several thermocouple-material pairs. Techniques of automatic reference junction compensation, span adjustment, and zero suppression are described that permit rapid selection of range and wire material, without the necessity for restandardization, by setting of two external tap switches.
ERIC Educational Resources Information Center
Ohio State Univ., Columbus. National Center for Research in Vocational Education.
This course, adapted from military curriculum materials for use in vocational and technical education, is designed to train students to perform as assistants to professional personnel in the care and treatment of patients in mental health units. It includes basic concepts of human behavior, the aspects of atypical adjustive reactions, the…
Guided wave methods and apparatus for nonlinear frequency generation
Durfee, III, Charles G.; Rundquist, Andrew; Kapteyn, Henry C.; Murnane, Margaret M.
2000-01-01
Methods and apparatus are disclosed for the nonlinear generation of sum and difference frequencies of electromagnetic radiation propagating in a nonlinear material. A waveguide having a waveguide cavity contains the nonlinear material. Phase matching of the nonlinear generation is obtained by adjusting a waveguide propagation constant, the refractive index of the nonlinear material, or the waveguide mode in which the radiation propagates. Phase matching can be achieved even in isotropic nonlinear materials. A short-wavelength radiation source uses phase-matched nonlinear generation in a waveguide to produce high harmonics of a pulsed laser.
3D-Printing âSmarterâ Energy Absorbing Materials
Duoss, Eric
2018-01-16
Foams are, by nature, disordered materials studded with air pockets of varying sizes. Lack of control over the materialâs architecture at the micrometer or nanometer scale can make it difficult to adjust the foamâs basic properties. But Eric Duoss and a team of Livermore researchers are using additive manufacturing to develop âsmarterâ silicone cushions. By architecting the structure at the micro scale, they are able to control macro-scale properties previously unachievable with foam materials.
Rotor blade construction for circulation control aircraft
NASA Technical Reports Server (NTRS)
Carter, Sr., Donald R. (Inventor); Sedlak, Matthew (Inventor); Krauss, Timothy A. (Inventor)
1986-01-01
A circulation control aircraft rotor blade having a spanwise Coanda surface 16 and a plurality of spanwise extending flexible composite material panels 18 cooperating with the surface to define slots for the discharge of compressed air from within the blade with each panel having first flexure means 60 associated with screw adjustments 36 for establishing a slot opening preload and second flexure means 62 associated with screw adjustments 38 for establishing a slot maximum opening.
3D-Printing ‘Smarter’ Energy Absorbing Materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duoss, Eric
2014-08-29
Foams are, by nature, disordered materials studded with air pockets of varying sizes. Lack of control over the material’s architecture at the micrometer or nanometer scale can make it difficult to adjust the foam’s basic properties. But Eric Duoss and a team of Livermore researchers are using additive manufacturing to develop “smarter” silicone cushions. By architecting the structure at the micro scale, they are able to control macro-scale properties previously unachievable with foam materials.
Compression for the management of venous leg ulcers: which material do we have?
Partsch, Hugo
2014-05-01
Compression therapy is the most important basic treatment modality in venous leg ulcers. The review focusses on the materials which are used: 1. Compression bandages, 2. Compression stockings, 3. Self-adjustable Velcro-devices, 4. Compression pumps, 5. Hybrid devices. Compression bandages, usually applied by trained staff, provide a wide spectrum of materials with different elastic properties. To make bandaging easier, safer and more effective, most modern bandages combine different material components. Self-management of venous ulcers has become feasible by introducing double compression stockings ("ulcer kits") and self-adjustable Velcro devices. Compression pumps can be used as adjunctive measures, especially for patients with restricted mobility. The combination of sustained and intermittent compression ("hybrid device") is a promising new tool. The interface pressure corresponding to the dosage of compression therapy determines the hemodynamic efficacy of each device. In order to reduce ambulatory venous hypertension compression pressures of more than 50 mm Hg in the upright position are desirable. At the same time pressure should be lower in the resting position in order to be tolerated. This prerequisite may be fulfilled by using inelastic, short stretch material including multicomponent bandages and cohesive surfaces, all characterized by high stiffness. Such materials do not give way when calf muscles contract during walking which leads to high peaks of interface pressure ("massaging effect"). © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Maxwell, James L; Rose, Chris R; Black, Marcie R; Springer, Robert W
2014-03-11
Microelectronic structures and devices, and method of fabricating a three-dimensional microelectronic structure is provided, comprising passing a first precursor material for a selected three-dimensional microelectronic structure into a reaction chamber at temperatures sufficient to maintain said precursor material in a predominantly gaseous state; maintaining said reaction chamber under sufficient pressures to enhance formation of a first portion of said three-dimensional microelectronic structure; applying an electric field between an electrode and said microelectronic structure at a desired point under conditions whereat said first portion of a selected three-dimensional microelectronic structure is formed from said first precursor material; positionally adjusting either said formed three-dimensional microelectronic structure or said electrode whereby further controlled growth of said three-dimensional microelectronic structure occurs; passing a second precursor material for a selected three-dimensional microelectronic structure into a reaction chamber at temperatures sufficient to maintain said precursor material in a predominantly gaseous state; maintaining said reaction chamber under sufficient pressures whereby a second portion of said three-dimensional microelectronic structure formation is enhanced; applying an electric field between an electrode and said microelectronic structure at a desired point under conditions whereat said second portion of a selected three-dimensional microelectronic structure is formed from said second precursor material; and, positionally adjusting either said formed three-dimensional microelectronic structure or said electrode whereby further controlled growth of said three-dimensional microelectronic structure occurs.
Lin, Shih-Yi; Lin, Cheng-Li; Chang, Chao-Hsiang; Wu, His-Chin; Wang, I-Kuan; Chou, Che-Yi; Liang, Ji-An
2017-01-01
Background The outcomes of upper tract urothelial carcinoma (UTUC) receiving radical nephroureterectomy were usually limited to small sample size, case-control studies, and often focused on cancer progression. Risk of acute myocardial infarction (AMI) in these patients was never investigated. Results The overall incidences of AMI were 3.39, 1.44, and 1.70 per 10,000 person-years in the radical nephroureterectomy, nonnephroureterectomy, and non-UTUC cohorts, respectively. Multivariable Cox proportional hazard regression analysis revealed a significantly higher AMI risk in the radical nephroureterectomy cohort [adjusted HR (aHR) = 1.83, 95% confidence interval (CI) = 1.08–3.11], compared with non-UTUC cohorts. The risk of mortality were the highest in patients with UTUC who had undergone radical nephroureterectomy [adjusted HR (aHR) = 5.37, 95% confidence interval (CI) = 4.80–6.02]. Materials and Methods From the Taiwan National Health Insurance claims data, 1,359 patients with UTUC who had undergone radical nephroureterectomy and 3,154 patients with UTUC who had undergone nephron sparing surgery and were newly diagnosed between 2000 and 2010 were identified. For each patient, 4 individuals without UTUC were randomly selected and frequency matched by age, sex, and diagnosis year. Conclusions Patients with UTUC who have undergone radical nephroureterectomy are at a higher risk of developing AMI, compared with those receiving nephron sparing surgery. PMID:29108329
Kamalak, Aliye; Uzun, Ismail; Arslan, Hakan; Keleş, Ali; Doğanay, Ezgi; Keskin, Cangül; Akçay, Merve
2016-10-01
Additional cleaning techniques and devices are required to remove maximum amount of residual filling material, which might limit disinfection of root canal system during retreatment. This study aimed to compare fracture resistance of roots when self-adjusting file (SAF), photon-induced photoacoustic streaming (PIPS), passive ultrasonic irrigation (PUI), erbium-doped yttrium aluminum garnet (Er:YAG), or neodymium-doped yttrium aluminum garnet (Nd:YAG) lasers are applied following the use of retreatment files in endodontics. A total of 117 human mandibular canine teeth of similar dimensions were selected and divided into nine groups (n = 13). Aside from control, instrumented, and only-prepared groups, 91 teeth were remaining, of which 13 were assigned to the only-filling group and final 78 to retreatment, thus R-Endo file, R-Endo+SAF, R-Endo+PUI, R-Endo+Er:YAG laser, R-Endo+Nd:YAG laser, and R-Endo+PIPS. The fracture strengths of the retreatment groups were lower than control, instrumented, and only-filling groups (p < 0.05). There was no difference between the R-Endo group and additional retreatment procedure groups (p > 0.05). Further cleaning methods using SAF, PIPS, Er:YAG laser, Nd:YAG laser, or PUI did not decrease the fracture resistance when compared with the R-Endo group.
Morassaei, Sara; Breslin, F Curtis; Ibrahim, Selahadin A; Smith, Peter M; Mustard, Cameron A; Amick, Benjamin C; Shankardass, Ketan; Petch, Jeremy
2013-05-01
This study sought to examine provincial variation in work injuries and to assess whether contextual factors are associated with geographic variation in work injuries. Individual-level data from the 2003 and 2005 Canadian Community Health Survey was obtained for a representative sample of 89,541 Canadians aged 15 to 75 years old who reported working in the past 12 months. A multilevel regression model was conducted to identify geographic variation and contextual factors associated with the likelihood of reporting an activity limiting work injury [corrected], while adjusting for demographic and work variables. Provincial differences in work injuries were observed, even after controlling for other risk factors. Workers in western provinces such as Saskatchewan (adjusted odds ratio [AOR], 1.30; 95% confidence interval [CI], 1.09-1.55), Alberta (AOR, 1.31; 95% CI, 1.13-1.51), and British Columbia (AOR, 1.46; 95% CI, 1.26-1.71) had a higher risk of work injuries compared with Ontario workers. Indicators of area-level material and social deprivation were not associated with work injury risk. Provincial differences in work injuries suggest that broader factors acting as determinants of work injuries are operating across workplaces at a provincial level. Future research needs to identify the provincial determinants and whether similar large area-level factors are driving work injuries in other countries. Copyright © 2013 Elsevier Inc. All rights reserved.
Design and optimization analysis of dual material gate on DG-IMOS
NASA Astrophysics Data System (ADS)
Singh, Sarabdeep; Raman, Ashish; Kumar, Naveen
2017-12-01
An impact ionization MOSFET (IMOS) is evolved for overcoming the constraint of less than 60 mV/decade sub-threshold slope (SS) of conventional MOSFET at room temperature. In this work, first, the device performance of the p-type double gate impact ionization MOSFET (DG-IMOS) is optimized by adjusting the device design parameters. The adjusted parameters are ratio of gate and intrinsic length, gate dielectric thickness and gate work function. Secondly, the DMG (dual material gate) DG-IMOS is proposed and investigated. This DMG DG-IMOS is further optimized to obtain the best possible performance parameters. Simulation results reveal that DMG DG-IMOS when compared to DG-IMOS, shows better I ON, I ON/I OFF ratio, and RF parameters. Results show that by properly tuning the lengths of two materials at a ratio of 1.5 in DMG DG-IMOS, optimized performance is achieved including I ON/I OFF ratio of 2.87 × 109 A/μm with I ON as 11.87 × 10-4 A/μm and transconductance of 1.06 × 10-3 S/μm. It is analyzed that length of drain side material should be greater than the length of source side material to attain the higher transconductance in DMG DG-IMOS.
NASA Astrophysics Data System (ADS)
Nyilas, A.; Weiss, K. P.
2008-03-01
A new extensometer capable of measuring diametral strains during axial loading of structural materials and superconducting composite wires has been developed. Using this new transducer it is possible to determine both the averaged axial strain and the transverse strain. The diametral extensometer with a mass of around 1 g is foreseen to be clamped onto the wire inside the averaging double extensometer sensing device system. The sensitivity of this new diametral extensometer is very high, nearly a factor of ten higher than the axial extensometer system. In addition, for structural materials and for composite materials an adjustable diametral extensometer enabling to test specimens between 5 mm and 15 mm diameter has been also developed and tested successfully at 4 K. For materials 304 L, Inconel 718, and modified Type 316LN stainless steel cast alloy the Poisson's coefficient could be determined at 295 K. Type 310 S stainless steel has been investigated at 7 K and at 4 K using the adjustable extensometer to determine the Poisson's coefficient, too. Furthermore, different types of superconducting A15 phase composite wires with diameters between 0.8 and 1.3 mm's were characterized in axial and diametral orientation.
Beam limiter for thermonuclear fusion devices
Kaminsky, Manfred S.
1976-01-01
A beam limiter circumscribes the interior surface of a vacuum vessel to inhibit collisions of contained plasma and the vessel walls. The cross section of the material making up the limiter has a flatsided or slightly concave portion of increased width towards the plasma and portions of decreased width towards the interior surface of the vessel. This configuration is designed to prevent a major fraction of the material sputtered, vaporized and blistered from the limiter from reaching the plasma. It also allows adequate heat transfer from the wider to the narrower portions. The preferred materials for the beam limiter are solids of sintered, particulate materials of low atomic number with low vapor pressure and low sputtering and blistering yields.
Thermodynamic limit for synthesis of metastable inorganic materials.
Aykol, Muratahan; Dwaraknath, Shyam S; Sun, Wenhao; Persson, Kristin A
2018-04-01
Realizing the growing number of possible or hypothesized metastable crystalline materials is extremely challenging. There is no rigorous metric to identify which compounds can or cannot be synthesized. We present a thermodynamic upper limit on the energy scale, above which the laboratory synthesis of a polymorph is highly unlikely. The limit is defined on the basis of the amorphous state, and we validate its utility by effectively classifying more than 700 polymorphs in 41 common inorganic material systems in the Materials Project for synthesizability. The amorphous limit is highly chemistry-dependent and is found to be in complete agreement with our knowledge of existing polymorphs in these 41 systems, whether made by the nature or in a laboratory. Quantifying the limits of metastability for realizable compounds, the approach is expected to find major applications in materials discovery.
Thermodynamic limit for synthesis of metastable inorganic materials
2018-01-01
Realizing the growing number of possible or hypothesized metastable crystalline materials is extremely challenging. There is no rigorous metric to identify which compounds can or cannot be synthesized. We present a thermodynamic upper limit on the energy scale, above which the laboratory synthesis of a polymorph is highly unlikely. The limit is defined on the basis of the amorphous state, and we validate its utility by effectively classifying more than 700 polymorphs in 41 common inorganic material systems in the Materials Project for synthesizability. The amorphous limit is highly chemistry-dependent and is found to be in complete agreement with our knowledge of existing polymorphs in these 41 systems, whether made by the nature or in a laboratory. Quantifying the limits of metastability for realizable compounds, the approach is expected to find major applications in materials discovery. PMID:29725618
30 CFR 7.99 - Critical characteristics.
Code of Federal Regulations, 2010 CFR
2010-07-01
... proper adjustments. (h) Material and dimensions of gaskets that are essential in maintaining the explosion-proof integrity of the diesel power package. (i) Dimensions and assembly of flame arresters. (j...
30 CFR 7.99 - Critical characteristics.
Code of Federal Regulations, 2011 CFR
2011-07-01
... proper adjustments. (h) Material and dimensions of gaskets that are essential in maintaining the explosion-proof integrity of the diesel power package. (i) Dimensions and assembly of flame arresters. (j...
30 CFR 7.99 - Critical characteristics.
Code of Federal Regulations, 2013 CFR
2013-07-01
... proper adjustments. (h) Material and dimensions of gaskets that are essential in maintaining the explosion-proof integrity of the diesel power package. (i) Dimensions and assembly of flame arresters. (j...
Extreme Precision Antenna Reflector Study Results
NASA Technical Reports Server (NTRS)
Sharp, G. R.; Gilger, L. D.; Ard, K. E.
1985-01-01
Thermal and mechanical distortion degrade the RF performance of antennas. The complexity of future communications antennas requires accurate, dimensionally stable antenna reflectors and structures built from materials other than those currently used. The advantages and disadvantages of using carbon fibers in an epoxy matrix are reviewed as well as current reflector fabrications technology and adjustment. The manufacturing sequence and coefficient of thermal expansion of carbon fiber/borosilicate glass composites is described. The construction of a parabolic reflector from this material and the assembling of both reflector and antenna are described. A 3M-aperture-diameter carbon/glass reflector that can be used as a subassembly for large reflectors is depicted. The deployment sequence for a 10.5M-aperture-diameter antenna, final reflector adjustment, and the deployment sequence for large reflectors are also illustrated.
NASA Astrophysics Data System (ADS)
Helman, David; Lensky, Itamar M.; Osem, Yagil; Rohatyn, Shani; Rotenberg, Eyal; Yakir, Dan
2017-09-01
Estimations of ecosystem-level evapotranspiration (ET) and CO2 uptake in water-limited environments are scarce and scaling up ground-level measurements is not straightforward. A biophysical approach using remote sensing (RS) and meteorological data (RS-Met) is adjusted to extreme high-energy water-limited Mediterranean ecosystems that suffer from continuous stress conditions to provide daily estimations of ET and CO2 uptake (measured as gross primary production, GPP) at a spatial resolution of 250 m. The RS-Met was adjusted using a seasonal water deficit factor (fWD) based on daily rainfall, temperature and radiation data. We validated our adjusted RS-Met with eddy covariance flux measurements using a newly developed mobile lab system and the single active FLUXNET station operating in this region (Yatir pine forest station) at a total of seven forest and non-forest sites across a climatic transect in Israel (280-770 mm yr-1). RS-Met was also compared to the satellite-borne MODIS-based ET and GPP products (MOD16 and MOD17, respectively) at these sites.Results show that the inclusion of the fWD significantly improved the model, with R = 0.64-0.91 for the ET-adjusted model (compared to 0.05-0.80 for the unadjusted model) and R = 0.72-0.92 for the adjusted GPP model (compared to R = 0.56-0.90 of the non-adjusted model). The RS-Met (with the fWD) successfully tracked observed changes in ET and GPP between dry and wet seasons across the sites. ET and GPP estimates from the adjusted RS-Met also agreed well with eddy covariance estimates on an annual timescale at the FLUXNET station of Yatir (266 ± 61 vs. 257 ± 58 mm yr-1 and 765 ± 112 vs. 748 ± 124 gC m-2 yr-1 for ET and GPP, respectively). Comparison with MODIS products showed consistently lower estimates from the MODIS-based models, particularly at the forest sites. Using the adjusted RS-Met, we show that afforestation significantly increased the water use efficiency (the ratio of carbon uptake to ET) in this region, with the positive effect decreasing when moving from dry to more humid environments, strengthening the importance of drylands afforestation. This simple yet robust biophysical approach shows promise for reliable ecosystem-level estimations of ET and CO2 uptake in extreme high-energy water-limited environments.
Sentse, Miranda; Kretschmer, Tina; de Haan, Amaranta; Prinzie, Peter
2017-08-01
Individual heterogeneity exists in the onset and development of conduct problems, but theoretical claims about predictors and prognosis are often not consistent with the empirical findings. This study examined shape and outcomes of conduct problem trajectories in a Belgian population-based sample (N = 682; 49.5 % boys). Mothers reported on children's conduct problems across six waves (age 4-17) and emerging adults reported on their behavioral adjustment (age 17-20). Applying mixture modeling, we found four gender-invariant trajectories (labeled life-course-persistent, adolescence-onset, childhood-limited, and low). The life-course-persistent group was least favorably adjusted, but the adolescence-onset group was similarly maladjusted in externalizing problems and may be less normative (15 % of the sample) than previously believed. The childhood-limited group was at heightened risk for specifically internalizing problems, being more worrisome than its label suggests. Interventions should not only be aimed at early detection of conduct problems, but also at adolescents to avoid future maladjustment.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-02
...NMFS proposes regulations to implement Framework Adjustment 2 to the Atlantic herring Fishery Management Plan and the 2013-2015 fishery specifications for the Atlantic herring fishery. Framework 2 would allow the New England Fishery Management Council to split annual catch limits seasonally for the four Atlantic herring management areas, and the carryover of unharvested catch, up to 10 percent for each area's annual catch limit. The specifications would set catch specifications for the herring fishery for the 2013-2015 fishing years and would establish seasonal splits for management areas 1A and 1B as recommended to NMFS by the New England Fishery Management Council.
NASA Astrophysics Data System (ADS)
Feng, Peilei; Xu, Tianqi; Liu, Xiaoxin; Jan, Lisheng; Dai, Xiaozhong; Cai, Pengcheng
2018-01-01
Nujiang power grid is at the end of the Yunnan power grid, which is the side of power supply. Due to the regional restrictions and the lag of economic development and other factors, the structure of the power grid in Nujiang is relatively weak, and the voltage of the regional power grid is more prominent. Based on analysis on voltage exceeding limits of Nujiang different power grid, combined with the operating characteristics of regional power grid and reactive power compensation measures, this paper proposes measures for adjustment of Nujiang grid voltage, and analyses the result of adjustment of voltage exceeding limits, which can effectively improve the voltage and power quality.
Binding, N; Schilder, K; Czeschinski, P A; Witting, U
1998-08-01
The 2,4-dinitrophenylhydrazine (2,4-DNPH) derivatization method mainly used for the determination of airborne formaldehyde was extended for acetaldehyde, acetone, 2-butanone, and cyclohexanone, the next four carbonyl compounds of industrial importance. Sampling devices and sampling conditions were adjusted for the respective limit value regulations. Analytical reliability criteria were established and compared to those of other recommended methods. With a minimum analytical range from one tenth to the 3-fold limit value in all cases and with relative standard deviations below 5%, the adjusted method meets all requirements for the reliable quantification of the four compounds in workplace air as well as in ambient air.
Multipoint vibrometry with dynamic and static holograms.
Haist, T; Lingel, C; Osten, W; Winter, M; Giesen, M; Ritter, F; Sandfort, K; Rembe, C; Bendel, K
2013-12-01
We report on two multipoint vibrometers with user-adjustable position of the measurement spots. Both systems are using holograms for beam deflection. The measurement is based on heterodyne interferometry with a frequency difference of 5 MHz between reference and object beam. One of the systems uses programmable positioning of the spots in the object volume but is limited concerning the light efficiency. The other system is based on static holograms in combination with mechanical adjustment of the measurement spots and does not have such a general efficiency restriction. Design considerations are given and we show measurement results for both systems. In addition, we analyze the sensitivity of the systems which is a major limitation compared to single point scanning systems.
Code of Federal Regulations, 2010 CFR
2010-04-01
....1502-91(d)(1). The testing period for L commences on August 1, Year 4. C's purchase of all the P stock... based on the value of the P stock immediately before the ownership change limits the amount of... allocation of income and loss). (2) Adjustment to value. Appropriate adjustments must be made to the extent...
43 CFR 3601.10 - Limitations on BLM's discretion to dispose of mineral materials.
Code of Federal Regulations, 2012 CFR
2012-10-01
... of mineral materials. 3601.10 Section 3601.10 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) MINERAL MATERIALS DISPOSAL Mineral Materials Disposal; General Provisions Limitations on Disposal of...
43 CFR 3601.10 - Limitations on BLM's discretion to dispose of mineral materials.
Code of Federal Regulations, 2011 CFR
2011-10-01
... of mineral materials. 3601.10 Section 3601.10 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) MINERAL MATERIALS DISPOSAL Mineral Materials Disposal; General Provisions Limitations on Disposal of...
43 CFR 3601.10 - Limitations on BLM's discretion to dispose of mineral materials.
Code of Federal Regulations, 2014 CFR
2014-10-01
... of mineral materials. 3601.10 Section 3601.10 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) MINERAL MATERIALS DISPOSAL Mineral Materials Disposal; General Provisions Limitations on Disposal of...
43 CFR 3601.10 - Limitations on BLM's discretion to dispose of mineral materials.
Code of Federal Regulations, 2013 CFR
2013-10-01
... of mineral materials. 3601.10 Section 3601.10 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) MINERAL MATERIALS DISPOSAL Mineral Materials Disposal; General Provisions Limitations on Disposal of...
Research and application of thermal power unit’s load dynamic adjustment based on extraction steam
NASA Astrophysics Data System (ADS)
Li, Jun; Li, Huicong; Li, Weiwei
2018-02-01
The rapid development of heat and power generation in large power plant has caused tremendous constraints on the load adjustment of power grids and power plants. By introducing the thermodynamic system of thermal power unit, the relationship between thermal power extraction steam and unit’s load has analyzed and calculated. The practical application results show that power capability of the unit affected by extraction and it is not conducive to adjust the grid frequency. By monitoring the load adjustment capacity of thermal power units, especially the combined heat and power generating units, the upper and lower limits of the unit load can be dynamically adjusted by the operator on the grid side. The grid regulation and control departments can effectively control the load adjustable intervals of the operating units and provide reliable for the cooperative action of the power grid and power plants, to ensure the safety and stability of the power grid.
Results Of Copper Catalyzed Peroxide Oxidation (CCPO) Of Tank 48H Simulants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.; Pareizs, J. M.; Newell, J. D.
2012-12-13
Savannah River National Laboratory (SRNL) performed a series of laboratory-scale experiments that examined copper-catalyzed hydrogen peroxide (H{sub 2}O{sub 2}) aided destruction of organic components, most notably tetraphenylborate (TPB), in Tank 48H simulant slurries. The experiments were designed with an expectation of conducting the process within existing vessels of Building 241-96H with minimal modifications to the existing equipment. Results of the experiments indicate that TPB destruction levels exceeding 99.9% are achievable, dependent on the reaction conditions. A lower reaction pH provides faster reaction rates (pH 7 > pH 9 > pH 11); however, pH 9 reactions provide the least quantity ofmore » organic residual compounds within the limits of species analyzed. Higher temperatures lead to faster reaction rates and smaller quantities of organic residual compounds. A processing temperature of 50°C as part of an overall set of conditions appears to provide a viable TPB destruction time on the order of 4 days. Higher concentrations of the copper catalyst provide faster reaction rates, but the highest copper concentration (500 mg/L) also resulted in the second highest quantity of organic residual compounds. The data in this report suggests 100-250 mg/L as a minimum. Faster rates of H{sub 2}O{sub 2} addition lead to faster reaction rates and lower quantities of organic residual compounds. An addition rate of 0.4 mL/hour, scaled to the full vessel, is suggested for the process. SRNL recommends that for pH adjustment, an acid addition rate 42 mL/hour, scaled to the full vessel, is used. This is the same addition rate used in the testing. Even though the TPB and phenylborates can be destroyed in a relative short time period, the residual organics will take longer to degrade to <10 mg/L. Low level leaching on titanium occurred, however, the typical concentrations of released titanium are very low (~40 mg/L or less). A small amount of leaching under these conditions is not surprising and is consistent with a previous study. Acidification with phosphoric and formic acids, in lieu of nitric acid, provides benefits in reducing the amount of benzene emitted over the lifetime of a reaction. Analyses of the post-reaction residual material indicate that slurry initially adjusted down to a pH 7 produced a greater degree of energetic material than material initially adjusted to a pH of 9. No more than 140 {micro}g/m{sup 3} of mercury was indicated in reactor head spaces at any time. An estimation of less than 1% of the initial mercury was vaporized in each experiment. A limited number of replicate tests were performed to determine experimental reproducibility. These tests indicate a reasonable degree of reproducibility. The conclusion of the simulant testing has provided a set of reaction conditions that can destroy the TPB and phenylborates quickly. While longer times will be required to degrade the residual organics, the reactions appear to perform in a consistent manner. A real waste test or tests are recommended and further investigation into the use of phosphoric or formic acid is warranted.« less
Scott, Kenneth; Fisher, Gwenith G; Barón, Anna E; Tompa, Emile; Stallones, Lorann; DiGuiseppi, Carolyn
2018-06-13
To examine whether falls are associated with the subsequent ability to work among workers 65 years and older. This longitudinal cohort study followed older workers enrolled in the Health and Retirement Study. Outcomes included time to health-related work limitation and to labor force exit. After adjustment multiple falls with or without a medically-treated injury were associated with time to limitation (HR = 1.77, 95% CI: 1.30-2.40; HR = 1.48, 95% CI: 1.26-1.73, respectively). Adjustment mitigated a crude relationship between falls and time to exit. Significant interactions suggest the relationship between falls and labor force exit depends on age, race and job demands. Falls, both non-injurious and injurious, are associated with subsequent health-related work limitation among workers 65 and older. Fall prevention activities would benefit workers who want or need to keep working past age 65.
USDA-ARS?s Scientific Manuscript database
An intelligent dressing is a self-adjusting material with multifunctional properties and/or a biosensor-interface designed to treat specific pathological issues of wounds at a molecular or cellular level. The ability to detect and treat excessive protease levels in wounds, one indicator of chronic w...
Calcium-Mediated Adhesion of Nanomaterials in Reservoir Fluids.
Eichmann, Shannon L; Burnham, Nancy A
2017-09-14
Globally, a small percentage of oil is recovered from reservoirs using primary and secondary recovery mechanisms, and thus a major focus of the oil industry is toward developing new technologies to increase recovery. Many new technologies utilize surfactants, macromolecules, and even nanoparticles, which are difficult to deploy in harsh reservoir conditions and where failures cause material aggregation and sticking to rock surfaces. To combat these issues, typically material properties are adjusted, but recent studies show that adjusting the dispersing fluid chemistry could have significant impact on material survivability. Herein, the effect of injection fluid salinity and composition on nanomaterial fate is explored using atomic force microscopy (AFM). The results show that the calcium content in reservoir fluids affects the interactions of an AFM tip with a calcite surface, as surrogates for nanomaterials interacting with carbonate reservoir rock. The extreme force sensitivity of AFM provides the ability to elucidate small differences in adhesion at the pico-Newton (pN) level and provides direct information about material survivability. Increasing the calcium content mitigates adhesion at the pN-scale, a possible means to increase nanomaterial survivability in oil reservoirs or to control nanomaterial fate in other aqueous environments.
Carvalho, Ana; Nabais, Cristina; Vieira, Joana; Rossi, Sergio; Campelo, Filipe
2015-01-01
The formation of wood results from cambial activity and its anatomical properties reflect the variability of environmental conditions during the growing season. Recently, it was found that wood density variations in conifers growing under cold-limited environment result from the adjustment of cell wall thickness (CWT) to temperature. Additionally, it is known that intra-annual density fluctuations (IADFs) are formed in response to precipitation after the summer drought. Although IADFs are frequent in Mediterranean conifers no study has yet been conducted to determine if these structures result from the adjustment of lumen diameter (LD) or CWT to soil water availability. Our main objective is to investigate the intra-ring variation of wood anatomical features (LD and CWT) in Pinus pinaster Ait. growing under a water-limited environment. We compared the tracheidograms of LD and CWT for the years 2010–2013 in P. pinaster growing in the west coast of Portugal. Our results suggest a close association between LD and soil moisture content along the growing season, reinforcing the role of water availability in determining tracheid size. Compared with CWT, LD showed a higher intra- and inter-annual variability suggesting its strong adjustment value to variations in water availability. The formation of a latewood IADF appears to be predisposed by higher rates of cell production in spring and triggered by early autumn precipitation. Our findings reinforce the crucial role of water availability on cambial activity and wood formation in Mediterranean conifers, and emphasize the high plasticity of wood anatomical features under Mediterranean climate. PMID:26305893
Carvalho, Ana; Nabais, Cristina; Vieira, Joana; Rossi, Sergio; Campelo, Filipe
2015-01-01
The formation of wood results from cambial activity and its anatomical properties reflect the variability of environmental conditions during the growing season. Recently, it was found that wood density variations in conifers growing under cold-limited environment result from the adjustment of cell wall thickness (CWT) to temperature. Additionally, it is known that intra-annual density fluctuations (IADFs) are formed in response to precipitation after the summer drought. Although IADFs are frequent in Mediterranean conifers no study has yet been conducted to determine if these structures result from the adjustment of lumen diameter (LD) or CWT to soil water availability. Our main objective is to investigate the intra-ring variation of wood anatomical features (LD and CWT) in Pinus pinaster Ait. growing under a water-limited environment. We compared the tracheidograms of LD and CWT for the years 2010-2013 in P. pinaster growing in the west coast of Portugal. Our results suggest a close association between LD and soil moisture content along the growing season, reinforcing the role of water availability in determining tracheid size. Compared with CWT, LD showed a higher intra- and inter-annual variability suggesting its strong adjustment value to variations in water availability. The formation of a latewood IADF appears to be predisposed by higher rates of cell production in spring and triggered by early autumn precipitation. Our findings reinforce the crucial role of water availability on cambial activity and wood formation in Mediterranean conifers, and emphasize the high plasticity of wood anatomical features under Mediterranean climate.
Optical phantoms with adjustable subdiffusive scattering parameters
NASA Astrophysics Data System (ADS)
Krauter, Philipp; Nothelfer, Steffen; Bodenschatz, Nico; Simon, Emanuel; Stocker, Sabrina; Foschum, Florian; Kienle, Alwin
2015-10-01
A new epoxy-resin-based optical phantom system with adjustable subdiffusive scattering parameters is presented along with measurements of the intrinsic absorption, scattering, fluorescence, and refractive index of the matrix material. Both an aluminium oxide powder and a titanium dioxide dispersion were used as scattering agents and we present measurements of their scattering and reduced scattering coefficients. A method is theoretically described for a mixture of both scattering agents to obtain continuously adjustable anisotropy values g between 0.65 and 0.9 and values of the phase function parameter γ in the range of 1.4 to 2.2. Furthermore, we show absorption spectra for a set of pigments that can be added to achieve particular absorption characteristics. By additional analysis of the aging, a fully characterized phantom system is obtained with the novelty of g and γ parameter adjustment.
ERIC Educational Resources Information Center
Hos, Rabia
2016-01-01
The educational landscape for schools in the United States is continuing to shift with the arrival of refugee students with limited or interrupted formal education, especially at the secondary schools. As refugee students with limited or interrupted formal education (SLIFE) adjust to schools in the United States, they may experience acculturative…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-06
... applicability of the OPA 90 single-hull tank vessel limits of liability. DATES: This final rule is effective... amendments to clarify the applicability of the single-hull tank vessel limits of liability, and solicited... regulations, at 33 CFR part 138, subpart A, to single- hull tank vessels that do not carry oil as cargo. As...
Rask, Shadia; Castaneda, Anu E; Koponen, Päivikki; Sainio, Päivi; Stenholm, Sari; Suvisaari, Jaana; Juntunen, Teppo; Halla, Tapio; Härkänen, Tommi; Koskinen, Seppo
2015-03-20
Research has demonstrated a bidirectional relationship between physical function and depression, but studies on their association in migrant populations are scarce. We examined the association between mental health symptoms and mobility limitation in Russian, Somali and Kurdish migrants in Finland. We used data from the Finnish Migrant Health and Wellbeing Study (Maamu). The participants comprised 1357 persons of Russian, Somali or Kurdish origin aged 18-64 years. Mobility limitation included self-reported difficulties in walking 500 m or stair climbing. Depressive and anxiety symptoms were measured using the Hopkins Symptom Checklist-25 (HSCL-25) and symptoms of somatization using the somatization subscale of the Symptom Checklist-90 Revised (SCL-90-R). A comparison group of the general Finnish population was selected from the Health 2011 study. Anxiety symptoms were positively associated with mobility limitation in women (Russians odds ratio [OR] 2.98; 95% confidence interval [CI] 1.28-6.94, Somalis OR 6.41; 95% CI 2.02-20.29 and Kurds OR 2.67; 95% CI 1.41-5.04), after adjustment for socio-demographic factors, obesity and chronic diseases. Also somatization increased the odds for mobility limitation in women (Russians OR 4.29; 95% CI 1.76-10.44, Somalis OR 18.83; 95% CI 6.15-57.61 and Kurds OR 3.53; 95% CI 1.91-6.52). Depressive symptoms were associated with mobility limitation in Russian and Kurdish women (Russians OR 3.03; 95% CI 1.27-7.19 and Kurds OR 2.64; 95% CI 1.39-4.99). Anxiety symptoms and somatization were associated with mobility limitation in Kurdish men when adjusted for socio-demographic factors, but not after adjusting for obesity and chronic diseases. Finnish women had similar associations as the migrant women, but Finnish men and Kurdish men showed varying associations. Mental health symptoms are significantly associated with mobility limitation both in the studied migrant populations and in the general Finnish population. The joint nature of mental health symptoms and mobility limitation should be recognized by health professionals, also when working with migrants. This association should be addressed when developing health services and health promotion.
Female starlings adjust primary sex ratio in response to aromatic plants in the nest.
Polo, Vicente; Veiga, José P; Cordero, Pedro J; Viñuela, Javier; Monaghan, Pat
2004-09-22
Adjustment of offspring sex ratios should be favoured by natural selection when parents are capable of facultatively altering brood sex ratios and of recognizing the circumstances that predict the probable fitness benefit of producing sons and daughters. Although experimental studies have shown that female birds may adjust offspring sex ratios in response to changes in their own condition and in the external appearance of their mate, and male attributes other than his external morphology are also thought to act as signals of male quality, it is not known whether females will respond to changes in such signals, in the absence of any change in the appearance of the male himself. Here, we experimentally manipulated a male courtship display, the green plants carried to the nest by male spotless starlings (Sturnus unicolor), without changing any physical attributes of the male himself, and examined whether this influenced female decisions on offspring sex ratio. We found that in an environment in which female starlings were producing more daughters than sons, experimental enhancement of the green nesting material caused females to significantly increase the number of male eggs produced and thereby removed the female bias. This effect was consistent in 2 years and at two localities. This demonstrates that the green material, whose function has long puzzled biologists, conveys important information to the female and that she facultatively adjusts offspring production accordingly.
Measurements and tests of HTS bulk material in resistive fault current limiters
NASA Astrophysics Data System (ADS)
Noe, M.; Juengst, K.-P.; Werfel, F. N.; Elschner, S.; Bock, J.; Wolf, A.; Breuer, F.
2002-08-01
The application of superconducting fault current limiters (SCFCL) depends highly on their technical and economical benefits. Therefore it is obvious that the main requirements on the SCFCL are a reliable, fail-safe and rapid current limitation, low losses, and an inexpensive production. As a potential candidate material we have investigated HTS bulk material in resistive fault current limiters. Our report focuses on the E- j-curves, the AC-losses and the quench behaviour of melt cast processed-BSCCO 2212 and melt textured polycrystalline-YBCO 123. Within a temperature range from 64 to 80 K E- j-curves and AC losses of HTS elements were measured. The measurement results show that HTS bulk material meets the SCFCL specifications. In order to avoid hot spots during limitation and to improve mechanical stability a metallic bypass is needed. First test results of the quench behaviour of HTS bulk material with metallic bypass demonstrate safe limitation up to the specified electrical field of 100 V/m.
Study on optimum length of raw material in stainless steel high-lock nuts forging
NASA Astrophysics Data System (ADS)
Cheng, Meiwen; Liu, Fenglei; Zhao, Qingyun; Wang, Lidong
2018-04-01
Taking 302 stainless steel (1Cr18Ni9) high-lock nuts for research objects, adjusting the length of raw material, then using DEFORM software to simulate the isothermal forging process of each station and conducting the corresponding field tests to study the effects of raw material size on the stainless steel high-lock nuts forming performance. The tests show that the samples of each raw material length is basically the same as the results of the DEFORM software. When the length of the raw material is 10mm, the appearance size of the parts can meet the design requirements.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-25
... social harm resulting from substantial reductions to the 2013 annual catch limits for several stocks... limit (ACL) for several Northeast (NE) multispecies (groundfish) stocks as part of Framework Adjustment... necessary to prevent overfishing and rebuild overfished groundfish stocks consistent with rebuilding plans...
40 CFR 266.106 - Standards to control metals emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... HAZARDOUS WASTE MANAGEMENT FACILITIES Hazardous Waste Burned in Boilers and Industrial Furnaces § 266.106... implemented by limiting feed rates of the individual metals to levels during the trial burn (for new... screening limit for the worst-case stack. (d) Tier III and Adjusted Tier I site-specific risk assessment...
40 CFR 266.106 - Standards to control metals emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... HAZARDOUS WASTE MANAGEMENT FACILITIES Hazardous Waste Burned in Boilers and Industrial Furnaces § 266.106... implemented by limiting feed rates of the individual metals to levels during the trial burn (for new... screening limit for the worst-case stack. (d) Tier III and Adjusted Tier I site-specific risk assessment...
50 CFR 635.34 - Adjustment of management measures.
Code of Federal Regulations, 2014 CFR
2014-10-01
... § 635.23; the quotas for BFT, shark and swordfish, as specified in § 635.27; the regional retention... retention limits, including target catch requirements; size limits; fishing years or fishing seasons; shark... groups to which they belong; species in the prohibited shark species group; classification system within...
Code of Federal Regulations, 2014 CFR
2014-10-01
... remain in effect through the end of the applicable fishing year or until otherwise adjusted. (e) Sharks... which they are being caught as specified under § 635.22(c). (1) All sharks landed under the recreational... sharks, except those specified at § 635.20(e)(4), landed under the recreational retention limits...
22 CFR 42.51 - Department control of numerical limitations.
Code of Federal Regulations, 2013 CFR
2013-04-01
....51 Section 42.51 Foreign Relations DEPARTMENT OF STATE VISAS VISAS: DOCUMENTATION OF IMMIGRANTS UNDER... shall limit the number of immigrant visas that may be issued and the number of adjustments of status... Department shall allocate immigrant visa numbers for use in connection with the issuance of immigrant visas...
22 CFR 42.51 - Department control of numerical limitations.
Code of Federal Regulations, 2014 CFR
2014-04-01
....51 Section 42.51 Foreign Relations DEPARTMENT OF STATE VISAS VISAS: DOCUMENTATION OF IMMIGRANTS UNDER... shall limit the number of immigrant visas that may be issued and the number of adjustments of status... Department shall allocate immigrant visa numbers for use in connection with the issuance of immigrant visas...
22 CFR 42.51 - Department control of numerical limitations.
Code of Federal Regulations, 2012 CFR
2012-04-01
....51 Section 42.51 Foreign Relations DEPARTMENT OF STATE VISAS VISAS: DOCUMENTATION OF IMMIGRANTS UNDER... shall limit the number of immigrant visas that may be issued and the number of adjustments of status... Department shall allocate immigrant visa numbers for use in connection with the issuance of immigrant visas...
Code of Federal Regulations, 2010 CFR
2010-10-01
... damaged by shark bites may be retained only if the length of the remainder of the fish is equal to or... after consideration of additional scientific information and fish measurement data, and will be made... otherwise adjusted. (e) Sharks. The following size limits change depending on the species being caught and...
ERIC Educational Resources Information Center
Misra, Anjali; Schloss, Patrick J.
1989-01-01
The critical analysis of 23 studies using respondent techniques for the reduction of excessive emotional reactions in school children focuses on research design, dependent variables, independent variables, component analysis, and demonstrations of generalization and maintenance. Results indicate widespread methodological flaws that limit the…
ERIC Educational Resources Information Center
Bound Brook Board of Education, NJ.
A research project focused on the development and use of sex-fair occupational knowledge materials with a sample of limited English-proficient students. First, researchers examined existing instructional materials from vocational education sources in order to identify materials that are written on a level appropriate for limited English-proficient…
All-optical framing photography based on hyperspectral imaging method
NASA Astrophysics Data System (ADS)
Liu, Shouxian; Li, Yu; Li, Zeren; Chen, Guanghua; Peng, Qixian; Lei, Jiangbo; Liu, Jun; Yuan, Shuyun
2017-02-01
We propose and experimentally demonstrate a new all optical-framing photography that uses hyperspectral imaging methods to record a chirped pulse's temporal-spatial information. This proposed method consists of three parts: (1) a chirped laser pulse encodes temporal phenomena onto wavelengths; (2) a lenslet array generates a series of integral pupil images;(3) a dispersive device disperses the integral images at void space of image sensor. Compared with Ultrafast All-Optical Framing Technology(Daniel Frayer,2013,2014) and Sequentially Time All-Optical Mapping Photography( Nakagawa 2014, 2015), our method is convenient to adjust the temporal resolution and to flexibly increase the numbers of frames. Theoretically, the temporal resolution of our scheme is limited by the amount of dispersion that is added to a Fourier transform limited femtosecond laser pulse. Correspondingly, the optimal number of frames is decided by the ratio of the observational time window to the temporal resolution, and the effective pixels of each frame are mostly limited by the dimensions M×N of the lenslet array. For example, if a 40fs Fourier transform limited femtosecond pulse is stretched to 10ps, a CCD camera with 2048×3072 pixels can record 15 framing images with temporal resolution of 650fs and image size of 100×100 pixels. As spectrometer structure, our recording part has another advantage that not only amplitude images but also frequency domain interferograms can be imaged. Therefore, it is comparatively easy to capture fast dynamics in the refractive index change of materials. A further dynamic experiment is being conducted.
Hayes, Eileen P; Jolly, Robert A; Faria, Ellen C; Barle, Ester Lovsin; Bercu, Joel P; Molnar, Lance R; Naumann, Bruce D; Olson, Michael J; Pecquet, Alison M; Sandhu, Reena; Shipp, Bryan K; Sussman, Robert G; Weideman, Patricia A
2016-08-01
A European Union (EU) regulatory guideline came into effect for all new pharmaceutical products on June 1st, 2015, and for all existing pharmaceutical products on December 1st, 2015. This guideline centers around the use of the Acceptable Daily Exposure (ADE) [synonymous with the Permitted Daily Exposure (PDE)] and operational considerations associated with implementation are outlined here. The EU guidance states that all active pharmaceutical ingredients (API) require an ADE; however, other substances such as starting materials, process intermediates, and cleaning agents may benefit from an ADE. Problems in setting ADEs for these additional substances typically relate to toxicological data limitations precluding the ability to establish a formal ADE. Established methodologies such as occupational exposure limits or bands (OELs or OEBs) and the threshold of toxicological concern (TTC) can be used or adjusted for use as interim ADEs when only limited data are available and until a more formal ADE can be established. Once formal ADEs are derived, it is important that the documents are routinely updated and that these updates are communicated to appropriate stakeholders. Another key operational consideration related to data-poor substances includes the use of maximum daily dose (MDD) in setting cross-contamination limits. The MDD is an important part of the maximum allowable/safe concentration (MAC/MSC) calculation and there are important considerations for its use and definition. Finally, other considerations discussed include operational aspects of setting ADEs for pediatrics, considerations for large molecules, and risk management in shared facilities. Copyright © 2016 Elsevier Inc. All rights reserved.
Means and apparatus for throttling a dry pulverized solid material pump
Meyer, J. W.; Daniel, Jr, A. D.; Bonin, J. H.
1982-12-07
Method and apparatus are shown for control of continuous feeding of pulverized material to a high pressure container. A rotor is located within the high pressure container. The pulverized material is fed from a feed hopper through a stationary feed pipe to a vented spin-up zone chamber to a plurality of sprues mounted in the rotor. Control of the pressure within control nozzles downstream from the sprues adjusts the flow rate of coal through the sprues. 9 figs.
Means and apparatus for throttling a dry pulverized solid material pump
Meyer, John W [Palo Alto, CA; Daniel, Jr., Arnold D.; Bonin, John H [Sunnyvale, CA
1982-01-01
Method and apparatus are shown for control of continuous feeding of pulverized material to a high pressure container. A rotor is located within the high pressure container. The pulverized material is fed from a feed hopper through a stationary feed pipe to a vented spin-up zone chamber to a plurality of sprues mounted in the rotor. Control of the pressure within control nozzles downstream from the sprues adjusts the flow rate of coal through the sprues.
X-ray backscatter imaging of nuclear materials
Chapman, Jeffrey Allen; Gunning, John E; Hollenbach, Daniel F; Ott, Larry J; Shedlock, Daniel
2014-09-30
The energy of an X-ray beam and critical depth are selected to detect structural discontinuities in a material having an atomic number Z of 57 or greater. The critical depth is selected by adjusting the geometry of a collimator that blocks backscattered radiation so that backscattered X-ray originating from a depth less than the critical depth is not detected. Structures of Lanthanides and Actinides, including nuclear fuel rod materials, can be inspected for structural discontinuities such as gaps, cracks, and chipping employing the backscattered X-ray.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marsh, S.F.; Spall, W.D.; Abernathey, R.M.
1976-11-01
Relationships are provided to compute the decreasing plutonium content and changing isotopic distribution of plutonium materials for the radioactive decay of /sup 238/Pu, /sup 239/Pu, /sup 240/Pu and /sup 242/Pu to long-lived uranium daughters and of /sup 241/Pu to /sup 241/Am. This computation is important to the use of plutonium reference materials to calibrate destructive and nondestructive methods for assay and isotopic measurements, as well as to accountability inventory calculations.
Controlled overspray spray nozzle
NASA Technical Reports Server (NTRS)
Prasthofer, W. P. (Inventor)
1981-01-01
A spray system for a multi-ingredient ablative material wherein a nozzle A is utilized for suppressing overspray is described. The nozzle includes a cyclindrical inlet which converges to a restricted throat. A curved juncture between the cylindrical inlet and the convergent portion affords unrestricted and uninterrupted flow of the ablative material. A divergent bell-shaped chamber and adjustable nozzle exit B is utilized which provides a highly effective spray pattern in suppressing overspray to an acceptable level and producing a homogeneous jet of material that adheres well to the substrate.
Surface temperatures and glassy state investigations in tribology
NASA Technical Reports Server (NTRS)
Bair, S.; Winer, W. O.
1979-01-01
The limiting shear stress shear rheological model was applied to property measurements pursuant to the use of the constitutive equation and the application of the constitutive equation to elastrohydrodynamic (EHD) traction. Experimental techniques were developed to subject materials to isothermal compression which is similar to the history the materials were subjected to in EHD contacts. In addition, an apparatus was developed for measuring the shear stress-strain behavior of solid lubricating materials. Four commercially available materials were examined under pressure. They exhibit elastic and limiting shear stress behavior similar to that of liquid lubricants. The application of the limiting shear stress model to traction predictions was extended employing the primary materials properties measured in the laboratory. The shear rheological model was also applied to a Grubin-like EHD inlet analysis for predicting film thicknesses when employing the limiting shear stress model material behavior.
Andrianto, Sonny; Jianhong, Ma; Hommey, Confidence; Damayanti, Devi; Wahyuni, Honey
2018-01-01
The present study examined the relationship between difficulty in re-entry adjustment and job embeddedness, considering the mediating role of sense of professional identity. The online data on demographic characteristics, difficulty on re-entry adjustment, sense of professional identity, and job embeddedness were collected from 178 Indonesian returnees from multiple organizations. The results showed that difficulty in re-entry adjustment was a significant predictor of a sense of professional identity; a sense of professional identity was a significant predictor of job embeddedness. Furthermore, sense of professional identity is an effective mediating variable, bridging the relationship between post-return conditions to the home country and work atmosphere. Finally, the key finding of this study was that sense of professional identity mediated the effect of difficulty in re-entry adjustment on job embeddedness. The theoretical and practical implications, study limitations, and future research needs of our findings are noted.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stover, Tracy E.; Baker, James S.; Ratliff, Michael D.
The classic Limiting Surface Density (LSD) method is an empirical calculation technique for analyzing and setting mass limits for fissile items in storage arrays. LSD is a desirable method because it can reduce or eliminate the need for lengthy detailed Monte Carlo models of storage arrays. The original (or classic) method was developed based on idealized arrays of bare spherical metal items in air-spaced cubic units in a water-reflected cubic array. In this case, the geometric and material-based surface densities were acceptably correlated by linear functions. Later updates to the method were made to allow for concrete reflection rather thanmore » water, cylindrical masses rather than spheres, different material forms, and noncubic arrays. However, in the intervening four decades since those updates, little work has been done to update the method, especially for use with contemporary highly heterogeneous shipping packages that are noncubic and stored in noncubic arrays. In this work, the LSD method is reevaluated for application to highly heterogeneous shipping packages for fissile material. The package modeled is the 9975 shipping package, currently the primary package used to store fissile material at Savannah River Site’s K-Area Complex. The package is neither cubic nor rectangular but resembles nested cylinders of stainless steel, lead, aluminum, and Celotex. The fissile content is assumed to be a cylinder of plutonium metal. The packages may be arranged in arrays with both an equal number of packages per side (package cubic) and an unequal number of packages per side (noncubic). The cubic arrangements are used to derive the 9975-specific material and geometry constants for the classic linear form LSD method. The linear form of the LSD, with noncubic array adjustment, is applied and evaluated against computational models for these packages to determine the critical unit fissile mass. Sensitivity equations are derived from the classic method, and these are also used to make projections of the critical unit fissile mass. It was discovered that the heterogeneous packages have a nonlinear surface density versus critical mass relationship compared to the acceptably linear response of bare spherical fissile masses. Methodology is developed to address the nonlinear response. In so doing, the solution to the nonlinear LSD method becomes decoupled from the critical mass of a single unit, adding to its flexibility. The ability of the method to predict changes in neutron multiplication due to perturbations in a parameter is examined to provide a basis for analyzing upset conditions. In conclusion, a full rederivation of the classic LSD method from diffusion theory is also included as this was found to be lacking in the available literature.« less
Stover, Tracy E.; Baker, James S.; Ratliff, Michael D.; ...
2018-03-02
The classic Limiting Surface Density (LSD) method is an empirical calculation technique for analyzing and setting mass limits for fissile items in storage arrays. LSD is a desirable method because it can reduce or eliminate the need for lengthy detailed Monte Carlo models of storage arrays. The original (or classic) method was developed based on idealized arrays of bare spherical metal items in air-spaced cubic units in a water-reflected cubic array. In this case, the geometric and material-based surface densities were acceptably correlated by linear functions. Later updates to the method were made to allow for concrete reflection rather thanmore » water, cylindrical masses rather than spheres, different material forms, and noncubic arrays. However, in the intervening four decades since those updates, little work has been done to update the method, especially for use with contemporary highly heterogeneous shipping packages that are noncubic and stored in noncubic arrays. In this work, the LSD method is reevaluated for application to highly heterogeneous shipping packages for fissile material. The package modeled is the 9975 shipping package, currently the primary package used to store fissile material at Savannah River Site’s K-Area Complex. The package is neither cubic nor rectangular but resembles nested cylinders of stainless steel, lead, aluminum, and Celotex. The fissile content is assumed to be a cylinder of plutonium metal. The packages may be arranged in arrays with both an equal number of packages per side (package cubic) and an unequal number of packages per side (noncubic). The cubic arrangements are used to derive the 9975-specific material and geometry constants for the classic linear form LSD method. The linear form of the LSD, with noncubic array adjustment, is applied and evaluated against computational models for these packages to determine the critical unit fissile mass. Sensitivity equations are derived from the classic method, and these are also used to make projections of the critical unit fissile mass. It was discovered that the heterogeneous packages have a nonlinear surface density versus critical mass relationship compared to the acceptably linear response of bare spherical fissile masses. Methodology is developed to address the nonlinear response. In so doing, the solution to the nonlinear LSD method becomes decoupled from the critical mass of a single unit, adding to its flexibility. The ability of the method to predict changes in neutron multiplication due to perturbations in a parameter is examined to provide a basis for analyzing upset conditions. In conclusion, a full rederivation of the classic LSD method from diffusion theory is also included as this was found to be lacking in the available literature.« less
40 CFR 227.9 - Limitations on quantities of waste materials.
Code of Federal Regulations, 2010 CFR
2010-07-01
... materials. 227.9 Section 227.9 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) OCEAN DUMPING CRITERIA FOR THE EVALUATION OF PERMIT APPLICATIONS FOR OCEAN DUMPING OF MATERIALS Environmental Impact § 227.9 Limitations on quantities of waste materials. Substances which may damage the ocean...
40 CFR 227.9 - Limitations on quantities of waste materials.
Code of Federal Regulations, 2013 CFR
2013-07-01
... materials. 227.9 Section 227.9 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) OCEAN DUMPING CRITERIA FOR THE EVALUATION OF PERMIT APPLICATIONS FOR OCEAN DUMPING OF MATERIALS Environmental Impact § 227.9 Limitations on quantities of waste materials. Substances which may damage the ocean...
40 CFR 227.9 - Limitations on quantities of waste materials.
Code of Federal Regulations, 2012 CFR
2012-07-01
... materials. 227.9 Section 227.9 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) OCEAN DUMPING CRITERIA FOR THE EVALUATION OF PERMIT APPLICATIONS FOR OCEAN DUMPING OF MATERIALS Environmental Impact § 227.9 Limitations on quantities of waste materials. Substances which may damage the ocean...
40 CFR 227.9 - Limitations on quantities of waste materials.
Code of Federal Regulations, 2011 CFR
2011-07-01
... materials. 227.9 Section 227.9 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) OCEAN DUMPING CRITERIA FOR THE EVALUATION OF PERMIT APPLICATIONS FOR OCEAN DUMPING OF MATERIALS Environmental Impact § 227.9 Limitations on quantities of waste materials. Substances which may damage the ocean...
40 CFR 227.9 - Limitations on quantities of waste materials.
Code of Federal Regulations, 2014 CFR
2014-07-01
... materials. 227.9 Section 227.9 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) OCEAN DUMPING CRITERIA FOR THE EVALUATION OF PERMIT APPLICATIONS FOR OCEAN DUMPING OF MATERIALS Environmental Impact § 227.9 Limitations on quantities of waste materials. Substances which may damage the ocean...
Xu, Jingping; Octavio E. Sequeiros,; Noble, Marlene A.
2014-01-01
The capacity of turbidity currents to carry sand and coarser sediment from shallow to deep regions in the submarine environment has attracted the attention of researchers from different disciplines. Yet not only are field measurements of oceanic turbidity currents a rare achievement, but also the data that have been collected consist mostly of velocity records with very limited or no suspended sediment concentration or grain size distribution data. This work focuses on two turbidity currents measured in Monterey Canyon in 2002 with emphasis on suspended sediment from unique samples collected within the body of these currents. It is shown that concentration and grain size of the suspended material, primarily controlled by the source of the gravity flows and their interaction with bed material, play a significant role in shaping the characteristics of the turbidity currents as they travel down the canyon. Before the flows reach their normal or quasi-steady state, which is defined by bed slope, bed roughness, and suspended grain size, they might pass through a preliminary adjustment stage where they are subject to capacity-driven deposition, and release heavy material in excess. Flows composed of fine (silt/clay) sediments tend to be thicker than those with sands. The measured velocity and concentration data confirm that flow patterns differ between the front and body of turbidity currents and that, even after reaching normal state, the flow regime can be radically disrupted by abrupt changes in canyon morphology.
[Sulfur dioxide limit standard and residues in Chinese medicinal materials].
Kang, Chuan-Zhi; Yang, Wan-Zhen; Mo, Ge; Zhou, Li; Jiang, Jing-Yi; Lv, Chao-Geng; Wang, Sheng; Zhou, Tao; Yang, Ye; Guo, Lan-Ping
2018-01-01
The traditional sulfur fumigation processing method has been widely used in the initial processing and storage of traditional Chinese medicinal materials due to its economy, efficiency, convenience, high operability and effect on mold and insect prevention. However, excessive sulfur fumigation of traditional Chinese medicinal materials would lead to the changes in chemical compositions, and even endanger human health. This study showed that traditional Chinese medicinal materials were sulfur fumigated directly after being harvested for quick drying, or fumigated after being weted in the storage process for preventing mold and insects. We found that the sulfur dioxide limits for traditional Chinese medicinal materials were stricter than those for foods. Based on the existing limit standards, we obtained the data of sulfur dioxide residues for 35 types of traditional Chinese medicinal materials in a total of 862 batches. According to the limit standard in the Chinese Pharmacopoeia (150, 400 mg·kg⁻¹), the average over-standard rate of sulfur dioxide was as high as 52.43%, but it was reduced to 29.47% if calculated based on the limit for vegetable additive standard (500 mg·kg⁻¹). Sulfur fumigation issue shall be considered correctly: sulfur dioxide is a type of low toxic substance and less dangerous than aflatoxin and other highly toxic substances, and a small amount of residue would not increase the toxicity of traditional Chinese medicinal materials. However, sulfur fumigation might change the content of chemical substances and affect the quality of traditional Chinese medicinal materials. Furthermore, the exposure hazards of toxic substances are comprehensively correlated with exposure cycle, exposure frequency, and application method. In conclusion, it is suggested to strengthen the studies on the limit standard of traditional Chinese medicinal materials, formulate practical and feasible limit standard for sulfur dioxide residues in traditional Chinese medicinal materials that are consistent with the medication characteristics of traditional Chinese medicinal materials and can guarantee people's demand for safe medication. Copyright© by the Chinese Pharmaceutical Association.
Detection technology research on the one-way clutch of automatic brake adjuster
NASA Astrophysics Data System (ADS)
Jiang, Wensong; Luo, Zai; Lu, Yi
2013-10-01
In this article, we provide a new testing method to evaluate the acceptable quality of the one-way clutch of automatic brake adjuster. To analysis the suitable adjusting brake moment which keeps the automatic brake adjuster out of failure, we build a mechanical model of one-way clutch according to the structure and the working principle of one-way clutch. The ranges of adjusting brake moment both clockwise and anti-clockwise can be calculated through the mechanical model of one-way clutch. Its critical moment, as well, are picked up as the ideal values of adjusting brake moment to evaluate the acceptable quality of one-way clutch of automatic brake adjuster. we calculate the ideal values of critical moment depending on the different structure of one-way clutch based on its mechanical model before the adjusting brake moment test begin. In addition, an experimental apparatus, which the uncertainty of measurement is ±0.1Nm, is specially designed to test the adjusting brake moment both clockwise and anti-clockwise. Than we can judge the acceptable quality of one-way clutch of automatic brake adjuster by comparing the test results and the ideal values instead of the EXP. In fact, the evaluation standard of adjusting brake moment applied on the project are still using the EXP provided by manufacturer currently in China, but it would be unavailable when the material of one-way clutch changed. Five kinds of automatic brake adjusters are used in the verification experiment to verify the accuracy of the test method. The experimental results show that the experimental values of adjusting brake moment both clockwise and anti-clockwise are within the ranges of theoretical results. The testing method provided by this article vividly meet the requirements of manufacturer's standard.
More, S J; Clegg, T A; Lynch, P J; O'Grady, L
2013-06-01
Somatic cell count (SCC) limits are a key component of national and international regulation for milk quality. As yet, very limited work has been published on SCC regulatory standards, including on the effect of different approaches to SCC data adjustment and interpretation. This study examines the effect of SCC data adjustment and interpretation, as outlined in current European Union (EU) legislation, on herd eligibility to supply raw milk for processing of dairy products for human consumption, using Irish data for illustration. The study used Irish milk-recording data as a proxy for bulk tank SCC (BTSCC) data, to calculate an unadjusted monthly SCC value for each herd during each month of participation. Subsequently, 4 data adjustments were applied, as outlined in EU and national legislation: seasonal adjustment; 3-mo rolling geometric average, without accounting for a break in the supply; 3-mo rolling geometric average, after accounting for a break in the supply; and seasonal adjustment and 3-mo rolling geometric average combined, after accounting for a break in the supply. Analyses were conducted to examine the effect, during the period from 2004 to 2010, of data adjustment on the percentage of herds with herd SCC >400,000 cells/mL. In all, 4 interpretation scenarios, incorporating different data adjustment combinations, were used to estimate herd eligibility (compliant, under warning, or suspended, as defined by legislation) to supply raw milk for processing. The 4 methods of data adjustment each led to a sizable reduction (6.7, 5.0, 5.3, and 11.1 percentage points, respectively, compared with the unadjusted data) in the percentage of herds exceeding a herd SCC of 400,000 cells/mL. Herd eligibility varied by interpretation scenarios, in particular those incorporating seasonal adjustment. The study provides new perspectives on the effect of data adjustment on herd SCC and of interpretation scenarios on herd eligibility. The results provide an illustrative, rather than definitive, picture of this effect, as national authorities use BTSCC data when determining herd eligibility, whereas this study was conducted using milk-recording data as a proxy. Some aspects of the primary EU legislation are unclear, which may lead to differences in interpretation and application. The potential impact of data adjustment and milk purchaser pricing on farm-level mastitis control in Ireland is considered. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Straňák, Zbyněk; Feyereislova, Simona; Černá, Marcela; Kollárová, Jana; Feyereisl, Jaroslav
2016-01-01
Objectives Breastfeeding is known to reduce infant morbidity and improve well-being. Nevertheless, breastfeeding rates remain low despite public health efforts. Our study aims to investigate the effect of controlled limited formula usage during birth hospitalisation on breastfeeding, using the primary hypothesis that early limited formula feeds in infants with early weight loss will not adversely affect the rate of exclusive or any breastfeeding as measured at discharge, 3 and 6 months of age. Material and Methods We randomly assigned 104 healthy term infants, 24 to 48 hours old, with ≥ 5% loss of birth weight to controlled limited formula (CLF) intervention (10 ml formula by syringe after each breastfeeding, discontinued at onset of lactation) or control group (standard approach, SA). Groups were compared for demographic data and breastfeeding rates at discharge, 3 months and 6 months of age (p-values adjusted for multiple testing). Results Fifty newborns were analysed in CLF and 50 in SA group. There were no differences in demographic data or clinical characteristics between groups. We found no evidence of difference between treatment groups in the rates of exclusive as well as any breastfeeding at discharge (p-value 0.2 and >0.99 respectively), 3 months (p-value 0.12 and 0.10) and 6 months of infants’ age (p-value 0.45 and 0.34 respectively). The percentage weight loss during hospitalisation was significantly higher in the SA group (7.3% in CLF group, 8.4% in SA group, p = 0.002). Conclusion The study shows that controlled limited formula use does not have an adverse effect on rates of breastfeeding in the short and long term. Larger studies are needed to confirm a possible potential in controlled limited formula use to support establishing breastfeeding and to help to improve the rates of breastfeeding overall. Trial Registration ISRCTN registry ISRCTN61915183 PMID:26918700
Motorized Beam Alignment of a Commercial X-ray Diffractometer
NASA Technical Reports Server (NTRS)
Van Zandt, Noah R.; Myers, James F.; Rogers, Richard B
2013-01-01
X-ray diffraction (XRD) is a powerful analysis method that allows researchers to noninvasively probe the crystalline structure of a material. This includes the ability to determine the crystalline phases present, quantify surface residual stresses, and measure the distribution of crystallographic orientations. The Structures and Materials Division at the NASA Glenn Research Center (GRC) heavily uses the on-site XRD lab to characterize advanced metal alloys, ceramics, and polymers. One of the x-ray diffractometers in the XRD lab (Bruker D8 Discover) uses three different x-ray tubes (Cu, Cr, and Mn) for optimal performance over numerous material types and various experimental techniques. This requires that the tubes be switched out and aligned between experiments. This alignment maximizes the x-ray tube s output through an iterative process involving four set screws. However, the output of the x-ray tube cannot be monitored during the adjustment process due to standard radiation safety engineering controls that prevent exposure to the x-ray beam when the diffractometer doors are open. Therefore, the adjustment process is a very tedious series of blind adjustments, each followed by measurement of the output beam using a PIN diode after the enclosure doors are shut. This process can take up to 4 hr to perform. This technical memorandum documents an in-house project to motorize this alignment process. Unlike a human, motors are not harmed by x-ray radiation of the energy range used in this instrument. Therefore, using motors to adjust the set screws will allow the researcher to monitor the x-ray tube s output while making interactive adjustments from outside the diffractometer. The motorized alignment system consists of four motors, a motor controller, and a hand-held user interface module. Our goal was to reduce the alignment time to less than 30 min. The time available was the 10-week span of the Lewis' Educational and Research Collaborative Internship Project (LERCIP) summer internship program and the budget goal was $1200. In this report, we will describe our motorization design and discuss the results of its implementation.
77 FR 60334 - New Marking Standards for Parcels Containing Hazardous Materials
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-03
... substances, certain patient specimens and certain radioactive materials as noted in section 135 of Mailing... due to its form, quantity, and packaging. Not all hazardous materials permitted to be shipped as a... mailable limited quantity materials that meet USPS quantity limitations and packaging requirements. All...