DOE Office of Scientific and Technical Information (OSTI.GOV)
Nigrey, P.J.; Dickens, T.G.; Dickman, P.T.
1997-08-01
Based on regulatory requirements for Type A and B radioactive material packaging, a Testing Program was developed to evaluate the effects of mixed wastes on plastic materials which could be used as liners and seals in transportation containers. The plastics evaluated in this program were butadiene-acrylonitrile copolymer (Nitrile rubber), cross-linked polyethylene, epichlorohydrin, ethylene-propylene rubber (EPDM), fluorocarbons, high-density polyethylene (HDPE), butyl rubber, polypropylene, polytetrafluoroethylene, and styrene-butadiene rubber (SBR). These plastics were first screened in four simulant mixed wastes. The liner materials were screened using specific gravity measurements and seal materials by vapor transport rate (VTR) measurements. For the screening of linermore » materials, Kel-F, HDPE, and XLPE were found to offer the greatest resistance to the combination of radiation and chemicals. The tests also indicated that while all seal materials passed exposure to the aqueous simulant mixed waste, EPDM and SBR had the lowest VTRs. In the chlorinated hydrocarbon simulant mixed waste, only Viton passed the screening tests. In both the simulant scintillation fluid mixed waste and the ketone mixture waste, none of the seal materials met the screening criteria. Those materials which passed the screening tests were subjected to further comprehensive testing in each of the simulant wastes. The materials were exposed to four different radiation doses followed by exposure to a simulant mixed waste at three temperatures and four different exposure times (7, 14, 28, 180 days). Materials were tested by measuring specific gravity, dimensional, hardness, stress cracking, VTR, compression set, and tensile properties. The second phase of this Testing Program involving the comprehensive testing of plastic liner has been completed and for seal materials is currently in progress.« less
Chemical compatibility screening results of plastic packaging to mixed waste simulants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nigrey, P.J.; Dickens, T.G.
1995-12-01
We have developed a chemical compatibility program for evaluating transportation packaging components for transporting mixed waste forms. We have performed the first phase of this experimental program to determine the effects of simulant mixed wastes on packaging materials. This effort involved the screening of 10 plastic materials in four liquid mixed waste simulants. The testing protocol involved exposing the respective materials to {approximately}3 kGy of gamma radiation followed by 14 day exposures to the waste simulants of 60 C. The seal materials or rubbers were tested using VTR (vapor transport rate) measurements while the liner materials were tested using specificmore » gravity as a metric. For these tests, a screening criteria of {approximately}1 g/m{sup 2}/hr for VTR and a specific gravity change of 10% was used. It was concluded that while all seal materials passed exposure to the aqueous simulant mixed waste, EPDM and SBR had the lowest VTRs. In the chlorinated hydrocarbon simulant mixed waste, only VITON passed the screening tests. In both the simulant scintillation fluid mixed waste and the ketone mixture simulant mixed waste, none of the seal materials met the screening criteria. It is anticipated that those materials with the lowest VTRs will be evaluated in the comprehensive phase of the program. For specific gravity testing of liner materials the data showed that while all materials with the exception of polypropylene passed the screening criteria, Kel-F, HDPE, and XLPE were found to offer the greatest resistance to the combination of radiation and chemicals.« less
Chemical compatibility screening test results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nigrey, P.J.; Dickens, T.G.
1997-12-01
A program for evaluating packaging components that may be used in transporting mixed-waste forms has been developed and the first phase has been completed. This effort involved the screening of ten plastic materials in four simulant mixed-waste types. These plastics were butadiene-acrylonitrile copolymer rubber, cross-linked polyethylene (XLPE), epichlorohydrin rubber, ethylene-propylene rubber (EPDM), fluorocarbon (Viton or Kel-F), polytetrafluoroethylene, high-density polyethylene (HDPE), isobutylene-isoprene copolymer rubber (butyl), polypropylene, and styrene-butadiene rubber (SBR). The selected simulant mixed wastes were (1) an aqueous alkaline mixture of sodium nitrate and sodium nitrite; (2) a chlorinated hydrocarbon mixture; (3) a simulant liquid scintillation fluid; and (4) amore » mixture of ketones. The testing protocol involved exposing the respective materials to 286,000 rads of gamma radiation followed by 14-day exposures to the waste types at 60{degrees}C. The seal materials were tested using vapor transport rate (VTR) measurements while the liner materials were tested using specific gravity as a metric. For these tests, a screening criterion of 0.9 g/hr/m{sup 2} for VTR and a specific gravity change of 10% was used. Based on this work, it was concluded that while all seal materials passed exposure to the aqueous simulant mixed waste, EPDM and SBR had the lowest VTRs. In the chlorinated hydrocarbon simulant mixed waste, only Viton passed the screening tests. In both the simulant scintillation fluid mixed waste and the ketone mixture simulant mixed waste, none of the seal materials met the screening criteria. For specific gravity testing of liner materials, the data showed that while all materials with the exception of polypropylene passed the screening criteria, Kel-F, HDPE, and XLPE offered the greatest resistance to the combination of radiation and chemicals.« less
Flash fire propensity of materials
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Cumming, H. J.
1977-01-01
Flash fire test results on 86 materials, evaluated using the USF flash fire screening test, are presented. The materials which appear least prone to flash fires are PVC, polyphenylene oxide and sulfide, and polyether and polyaryl sulfone; these did not produce flash fires under these particular test conditions. The principal value of these screening tests at the present time is in identifying materials which appear prone to flash fires, and in identifying which formulations of a generic material are more or less prone to flash fires.
NASA Technical Reports Server (NTRS)
Arnold, J.; Dodson, J.; Laub, B.
1979-01-01
Subscale solid motor nozzles containing a baseline material or low cost materials to be considered as potential replacements for the baseline material are designed and tested. Data are presented from tests of four identically designed 2.5 inch throat diameter nozzles and one 7 inch throat diameter nozzle. The screening of new candidate low cost materials, as well as their thermophysical and thermochemical characterization is also discussed.
Mesa, Matthew G.; Liedtke, Theresa L.; Weiland, Lisa K.; Christiansen, Helena E.
2017-12-14
In previous tests of the effectiveness of four common fish screen materials for excluding lamprey ammocoetes, we determined that woven wire (WW) allowed substantially more entrainment than perforated plate (PP), profile bar (PB), or Intralox (IL) material. These tests were simplistic because they used small vertically-oriented screens positioned perpendicular to the flow without a bypass or a sweeping velocity (SV). In the subsequent test discussed in this report, we exposed ammocoetes to much larger (2.5-m-wide) screen panels with flows up to 10 ft3 /s, a SV component, and a simulated bypass channel. The addition of a SV modestly improved protection of lamprey ammocoetes for all materials tested. A SV of 35 cm/s with an approach velocity (AV) of 12 cm/s, was able to provide protection for fish about 5–15 mm smaller than the protection provided by an AV of 12 cm/s without a SV component. The best-performing screen panels (PP, IL, and PB) provided nearly complete protection from entrainment for fish greater than 50-mm toal length, but the larger openings in the WW material only protected fish greater than 100-mm total length. Decreasing the AV and SV by 50 percent expanded the size range of protected lampreys by about 10–15 mm for those exposed to IL and WW screens, and it decreased the protective ability of PP screens by about 10 mm. Much of the improvement for IL and WW screens under the reduced flow conditions resulted from an increase in the number of lampreys swimming away from the screen. Fish of all sizes became impinged (that is, stuck on the screen surface for more than 1 s) on the screens, with the rate of impingement highest on PP (39– 72 percent) and lowest on WW (7–22 percent). Although impingements were common, injuries were rare, and 24-h post-test survival was greater than 99 percent. Our results refined the level of protection provided by these screen materials when both an AV and SV are present and confirmed our earlier recommendation that WW screens be replaced with more effective materials. Future work should focus on determining the risks associated with other screen types (for example, rotary drum screens, horizontal flat plate screens) and exploring the effectiveness of higher SV:AV ratios, because it may help expand the range of sizes protected by the best performing materials.
Evaluation of a standard test method for screening fuels in soils
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sorini, S.S.; Schabron, J.F.
1996-12-31
A new screening method for fuel contamination in soils was recently developed as American Society for Testing and Materials (ASTM) Method D-5831-95, Standard Test Method for Screening Fuels in Soils. This method uses low-toxicity chemicals and can be sued to screen organic- rich soils, as well as being fast, easy, and inexpensive to perform. Fuels containing aromatic compounds, such as diesel fuel and gasoline, as well as other aromatic-containing hydrocarbon materials, such as motor oil, crude oil, and cola oil, can be determined. The screening method for fuels in soils was evaluated by conducting a Collaborative study on the method.more » In the Collaborative study, a sand and an organic soil spiked with various concentrations of diesel fuel were tested. Data from the Collaborative study were used to determine the reproducibility (between participants) and repeatability (within participants) precision of the method for screening the test materials. The Collaborative study data also provide information on the performance of portable field equipment (patent pending) versus laboratory equipment for performing the screening method and a comparison of diesel concentration values determined using the screening method versus a laboratory method.« less
Thermal Protection System Aerothermal Screening Tests in HYMETS Facility
NASA Technical Reports Server (NTRS)
Szalai, Christine E.; Beck, Robin A. S.; Gasch, Matthew J.; Alumni, Antonella I.; Chavez-Garcia, Jose F.; Splinter, Scott C.; Gragg, Jeffrey G.; Brewer, Amy
2011-01-01
The Entry, Descent, and Landing (EDL) Technology Development Project has been tasked to develop Thermal Protection System (TPS) materials for insertion into future Mars Entry Systems. A screening arc jet test of seven rigid ablative TPS material candidates was performed in the Hypersonic Materials Environmental Test System (HYMETS) facility at NASA Langley Research Center, in both an air and carbon dioxide test environment. Recession, mass loss, surface temperature, and backface thermal response were measured for each test specimen. All material candidates survived the Mars aerocapture relevant heating condition, and some materials showed a clear increase in recession rate in the carbon dioxide test environment. These test results supported subsequent down-selection of the most promising material candidates for further development.
Jones, P A; King, A V
2003-01-01
Testing for phototoxic hazard is usually carried out for product ingredients intended for use on skin, which may be exposed to sunlight. Unilever currently uses the validated in vitro 3T3 Neutral Red Uptake phototoxicity test (NRU PT). This protocol involves 2-3 experiments, each taking 3 days to perform. One person can test up to seven test materials plus positive control at any one time, requiring approximately 0.5 g test material. Higher throughput is required where libraries of potential actives are being generated and screening for potential phototoxicants is required. A proposed HTS protocol would use the NRU PT, but only one concentration (10 microg/ml) in a single experiment. The validity of the HTS protocol was investigated by a retrospective examination of data from 86 materials previously tested. Phototoxic hazard predictions made using the conventional NRU PT were compared with those obtained if only data at 10 microg/ml were considered. A majority of 73 materials (84.9%) gave agreement in predictions between the two protocols; for 13 materials (15.1%) the assessments did not agree. There were no false positives; however, there were some false negatives, i.e., predicted as phototoxic from the conventional assay, but non-phototoxic at 10 microg/ml. As this protocol is intended for screening purposes only it is considered that this would be acceptable at this stage in material selection. One person could screen 128 test materials in 3 days, requiring <1 mg test material, giving a substantial increase in productivity. Any material selected for further development and inclusion in a formulation may require further confirmatory testing, e.g. using a human skin model assay for phototoxicity.
NASA Technical Reports Server (NTRS)
DelPapa, Steven V.
2005-01-01
Arc jet tests of candidate tile repair materials and baseline Orbiter uncoated reusable surface insulation (RSI) were performed in the Johnson Space Center's (JSC) Atmospheric Reentry Materials and Structures Evaluation Facility (ARMSEF) from June 23, 2003, through August 19, 2003. These tests were performed to screen candidate tile repair materials by verifying the high temperature performance and determining the thermal stability. In addition, tests to determine the surface emissivity at high temperatures and the geometric shrinkage of bare RSI were performed. In addition, tests were performed to determine the surface emissivity at high temperatures and the geometric shrinkage of uncoated RSI.
NASA Technical Reports Server (NTRS)
Wilkinson, W. H.; Kirkhart, F. P.; Kistler, C. W.; Duckworth, W. H.; Ungar, E. W.; Foster, E. L.
1970-01-01
Technical problems of design and flight qualification of the proposed classes of surface insulation materials and leading edge materials were reviewed. A screening test plan, a preliminary design data test plan and a design data test plan were outlined. This program defined the apparent critical differences between the surface insulators and the leading edge materials, structuring specialized screening test plans for each of these two classes of materials. Unique testing techniques were shown to be important in evaluating the structural interaction aspects of the surface insulators and a separate task was defined to validate the test plan. In addition, a compilation was made of available information on proposed material (including metallic TPS), previous shuttle programs, pertinent test procedures, and other national programs of merit. This material was collected and summarized in an informally structured workbook.
NASA Technical Reports Server (NTRS)
Oldrieve, R. E.
1971-01-01
Fourteen materials were evaluated in engine screening tests on full-size thermal reactors for automobile engine pollution control systems. Cyclic test-stand engine operation provided 2 hours at 1040 C and a 20-minute air-cool to 70 C each test cycle. Each reactor material was exposed to 83 cycles in 200 hours of engine testing. On the basis of resistance to oxidation and distortion, the best materials included two ferritic iron alloys (Ge 1541 and Armco 18S/R), several commercial oxidation-resistant coatings on AlSl 651 (19-9 DL), and possibly uncoated AISI 310. The best commercial coatings were Cr-Al, Ni-Cr, and a glass ceramic.
Screening materials for smoke evolution
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Cumming, H. J.; Machado, A. M.
1978-01-01
The density of smoke produced by burning or smoldering materials is a factor that affects the ability of occupants to escape from a burning structure and the effectiveness of firefighters. Accordingly, considerable effort is being spent on developing materials that minimize the amount of smoke without impairing their performance characteristics. In the present paper, laboratory tests on such materials are described and evaluated. It is seen that the National Bureau of Standards smoke test and the Ohio State University release-rate test are the most promising for screening materials for smoke evolution. It is shown that, for plastics, smoke obscuration is a more realistic concern than smoke toxicity.
Thermal Testing and Analysis of an Efficient High-Temperature Multi-Screen Internal Insulation
NASA Technical Reports Server (NTRS)
Weiland, Stefan; Handrick, Karin; Daryabeigi, Kamran
2007-01-01
Conventional multi-layer insulations exhibit excellent insulation performance but they are limited to the temperature range to which their components reflective foils and spacer materials are compatible. For high temperature applications, the internal multi-screen insulation IMI has been developed that utilizes unique ceramic material technology to produce reflective screens with high temperature stability. For analytical insulation sizing a parametric material model is developed that includes the main contributors for heat flow which are radiation and conduction. The adaptation of model-parameters based on effective steady-state thermal conductivity measurements performed at NASA Langley Research Center (LaRC) allows for extrapolation to arbitrary stack configurations and temperature ranges beyond the ones that were covered in the conductivity measurements. Experimental validation of the parametric material model was performed during the thermal qualification test of the X-38 Chin-panel, where test results and predictions showed a good agreement.
Validation of Microtox as a first screening tool for waste classification.
Weltens, R; Deprez, K; Michiels, L
2014-12-01
The Waste Framework Directive (WFD; 2008/98/EG) describes how waste materials are to be classified as hazardous or not. For complex waste materials chemical analyses are often not conclusive and the WFD provides the possibility to assess the hazardous properties by testing on the waste materials directly. As a methodology WFD refers to the protocols described in the CLP regulation (regulation on Classification, Labeling and Packaging of chemicals) but the toxicity tests on mammals are not acceptable for waste materials. The DISCRISET project was initiated to investigate the suitability of alternative toxicity tests that are already in use in pharmaceutical applications, for the toxicological hazard assessment of complex waste materials. Results indicated that Microtox was a good candidate as a first screening test in a tiered approached hazard assessment. This is now further validated in the present study. The toxic responses measured in Microtox were compared to biological responses in other bioassays for both organic and inorganic fractions of the wastes. Both fractions contribute to the toxic load of waste samples. Results show that the Microtox test is indeed a good and practical screening tool for the organic fraction. A screening threshold (ST) of 5 geq/l as the EC50 value in Microtox is proposed as this ST allows to recognize highly toxic samples in the screening test. The data presented here show that the Microtox toxicity response at this ST is not only predictive for acute toxicity in other organisms but also for sub lethal toxic effects of the organic fraction. This limit value has to be further validated. For the inorganic fraction no specific biotest can be recommended as a screening test, but the use of direct toxicity assessment is also preferable for this fraction as metal speciation is an important issue to define the toxic load of elutriate fractions. A battery of 3 tests (Microtox, Daphnia and Algae) for direct toxicity assessment of this fraction is recommended in literature, but including tests for mechanistic toxicity might be useful. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Greenberg, H. S.
1994-01-01
This document is the detailed test plan for the series of tests enumerated in the preceding section. The purpose of this plan is to present the test objectives, test parameters and procedures, expected performance and data analysis plans, criteria for success, test schedules, and related safety provisions and to describe the test articles, test instrumentation, and test facility requirements. Initial testing will be performed to screen four composite materials for suitability for SSTO LH2 tank loads and environmental conditions. The laminates for this testing will be fabricated by fiber placement, which is the manufacturing approach identified as baseline for the tank wall. Even though hand layup will be involved in fabricating many of the internal structural members of the tank, no hand-layup laminates will be evaluated in the screening or subsequent characterization testing. This decision is based on the understanding that mechanical properties measured for hand-layup material should be at least equivalent to properties measured for fiber-placed material, so that the latter should provide no less than a conservative approximation of the former. A single material will be downselected from these screening tests. This material will be subsequently characterized for impact-damage tolerance and durability under conditions of mechanical and thermal cycling, and to establish a preliminary design database to support ongoing analysis. Next, testing will be performed on critical structural elements fabricated from the selected material. Finally, the 8-foot diameter tank article, containing the critical structural features of the full-scale tank, will be fabricated by fiber placement and tested to verify its structural integrity and LH2 containment.
Leung, Doris Y P; Chen, Joanne M T; Lou, Vivian W Q; Wong, Eliza M L; Chan, Aileen W K; So, Winnie K W; Chan, Carmen W H
2017-07-13
Colorectal cancer (CRC) screening is a cost-effective prevention and control strategy. However, the promotion of CRC screening for older adults may be difficult because reading CRC prevention information may evoke embarrassment, fear, and anxiety towards the screening procedure and cancer diagnosis. This study aims to (1) examine the effects of three promotional materials for CRC screening on the attitudes toward CRC screening tests (screening interest, screening effectiveness, and trust in the screening results) and cancer fear, and (2) to explore the interaction effect of cancer fear with screening effectiveness and trust in the screening results on screening interest of the three screening tests (fecal occult blood test (FOBT), flexible sigmoidoscopy, and colonoscopy) among Chinese older adults. A total of 114 community-dwelling older adults were asked to look at the corresponding promotional materials (pamphlet, cartoon, and video) of one of the three study groups. The pamphlet and video represent convention strategies and the cartoon represents an innovative strategy. No significant difference was observed in the screening interest and cancer fear across groups. FOBT was the most preferred screening modality. The video group has a large proportion agreed screening effectiveness of flexible sigmoidoscopy than pamphlet and cartoon groups and trusted in the screening results for FOBT and flexible sigmoidoscopy than the pamphlet group. Logistic regression results showed that the effect of trust in the screening results on screening interest for colonoscopy was greater among participants with higher cancer fear than those with lower cancer fear level. In conclusion, the three promotional groups had produced similar results in their attitudes toward CRC screening and cancer fear. The use of cartoons may be a comparable approach with conventional methods in the promotion of CRC screening. Additional components that can arouse fear and boost response efficacy simultaneously might also be useful for the effective promotion of colonoscopy among Chinese older adults.
Leung, Doris Y. P.; Chen, Joanne M. T.; Lou, Vivian W. Q.; Wong, Eliza M. L.; So, Winnie K. W.; Chan, Carmen W. H.
2017-01-01
Colorectal cancer (CRC) screening is a cost-effective prevention and control strategy. However, the promotion of CRC screening for older adults may be difficult because reading CRC prevention information may evoke embarrassment, fear, and anxiety towards the screening procedure and cancer diagnosis. This study aims to (1) examine the effects of three promotional materials for CRC screening on the attitudes toward CRC screening tests (screening interest, screening effectiveness, and trust in the screening results) and cancer fear, and (2) to explore the interaction effect of cancer fear with screening effectiveness and trust in the screening results on screening interest of the three screening tests (fecal occult blood test (FOBT), flexible sigmoidoscopy, and colonoscopy) among Chinese older adults. A total of 114 community-dwelling older adults were asked to look at the corresponding promotional materials (pamphlet, cartoon, and video) of one of the three study groups. The pamphlet and video represent convention strategies and the cartoon represents an innovative strategy. No significant difference was observed in the screening interest and cancer fear across groups. FOBT was the most preferred screening modality. The video group has a large proportion agreed screening effectiveness of flexible sigmoidoscopy than pamphlet and cartoon groups and trusted in the screening results for FOBT and flexible sigmoidoscopy than the pamphlet group. Logistic regression results showed that the effect of trust in the screening results on screening interest for colonoscopy was greater among participants with higher cancer fear than those with lower cancer fear level. In conclusion, the three promotional groups had produced similar results in their attitudes toward CRC screening and cancer fear. The use of cartoons may be a comparable approach with conventional methods in the promotion of CRC screening. Additional components that can arouse fear and boost response efficacy simultaneously might also be useful for the effective promotion of colonoscopy among Chinese older adults. PMID:28703752
Some possible reference materials for fire toxicity tests
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Solis, A. N.
1977-01-01
Suitable reference materials need to be selected in order to standardize any test method. The evaluation of cotton, polyethylene, polyether sulfone, polycarbonate, polystyrene, and polyurethane flexible and rigid foams as possible reference materials for the University of San Francisco/NASA toxicity screening test method is discussed.
Development and application of a general plasmid reference material for GMO screening.
Wu, Yuhua; Li, Jun; Wang, Yulei; Li, Xiaofei; Li, Yunjing; Zhu, Li; Li, Jun; Wu, Gang
The use of analytical controls is essential when performing GMO detection through screening tests. Additionally, the presence of taxon-specific sequences is analyzed mostly for quality control during GMO detection. In this study, 11 commonly used genetic elements involving three promoters (P-35S, P-FMV35S and P-NOS), four marker genes (Bar, NPTII, HPT and Pmi), and four terminators (T-NOS, T-35S, T-g7 and T-e9), together with the reference gene fragments from six major crops of maize, soybean, rapeseed, rice, cotton and wheat, were co-integrated into the same single plasmid to construct a general reference plasmid pBI121-Screening. The suitability test of pBI121-Screening plasmid as reference material indicated that the non-target sequence on the pBI121-Screening plasmid did not affect the PCR amplification efficiencies of screening methods and taxon-specific methods. The sensitivity of screening and taxon-specific assays ranged from 5 to 10 copies of pBI121-Screening plasmid, meeting the sensitivity requirement of GMO detection. The construction of pBI121-Screening solves the lack of a general positive control for screening tests, thereby reducing the workload and cost of preparing a plurality of the positive control. Copyright © 2016 Elsevier B.V. All rights reserved.
Developing and testing lay literature about breast cancer screening for African American women.
Coleman, Elizabeth Ann; Coon, Sharon; Mohrmann, Carolyn; Hardin, Susan; Stewart, Beth; Gibson, Regina Shoate; Cantrell, Mary; Lord, Janet; Heard, Jeanne
2003-01-01
Written materials about breast cancer screening for African American women with low literacy skills are needed. Available materials were not at or below third-grade reading levels, were not culturally sensitive, and were not accurate in illustrating correct breast self-examination (BSE) techniques. Focus groups representing the target population helped the authors design a pamphlet describing how to perform BSE and a motivational picture book to help women overcome barriers to screening. The authors chose a food theme for the cover of the pamphlet written at a third-grade level and suggested a photographic version. In the motivational book, two women address barriers to screening and replace myths and fears with facts and actions. Data from 162 women showed that they learned from both the photographic and illustrated versions. Women in the photographic group found significantly more lumps in the silicone models, so the authors chose that version to use in final testing. Finally, nurses pretested a group of patients before they reviewed the materials and post-tested another group after they reviewed them. The group who had reviewed the materials had greater knowledge of and intent to follow the guidelines and received higher scores on BSE techniques.
NASA Astrophysics Data System (ADS)
Giacalone, Philip L.
1993-06-01
The design of the Intelsat VII surface tension propellant management device (PMD) (an all-welded assembly consisting of about 100 individual components) was developed using a modular design approach that allowed the complex PMD assembly to be divided into smaller modules. The modular approach reduces manufacturing-related technical and schedule risks and allows many components and assemblies to be processed in parallel, while also facilitating the incorporation of quality assurance tests at all critical PMD subassembly levels. The baseline PMD assembly is made from titanium and stainless steel materials. In order to obtain a 100 percent titanium PMD, a new, state-of-the-art fine mesh titanium screen material was developed, tested, and qualified for use as an alternaltive to the stainless steel screen material. The Ti based screen material demonstrated a high level of bubble point performance. It was integrated into a PMD assembly and was successfully qualification tested at the tank assembly level.
Dreier, M; Borutta, B; Seidel, G; Münch, I; Töppich, J; Bitzer, E-M; Dierks, M-L; Walter, U
2014-03-01
In Germany, individuals who have statutory health insurance have free access to colorectal cancer (CRC) screening tests, and can choose between a fecal occult blood test and a screening colonoscopy. Evidence-based health information may support informed choices regarding whether or not to undergo CRC screening. The aim of this study was to assess whether the available German information materials on CRC screening meet evidence-based health information standards. A systematic search was made for print media and websites on CRC screening addressed to German people with average CRC risk (search period for print media August 2010, for websites January-March 2012). The identified information was assessed with a newly developed comprehensive list of criteria. In all, 41 print media, including 28 flyers and 13 brochures, and 36 websites were identified and assessed. These materials reported more often the benefits than the risks of CRC screening, and quantified presentations of benefits and risks were less frequently given. Most of the materials called for participation and did not indicate the option to decide whether or not to attend CRC screening. This bias in favor of screening was increased by fear-provoking or downplayed wording. Most materials included false and misleading information. The requirements for evidence-based patient information were currently not met by most of the leaflets and websites in Germany. Feedback was given to the producers of the leaflets including a discussion of the findings. The results may be used to revise existing leaflets or to develop new health information on CRC screening.
van der Meulen, Miriam P; Lansdorp-Vogelaar, Iris; Goede, S Lucas; Kuipers, Ernst J; Dekker, Evelien; Stoker, Jaap; van Ballegooijen, Marjolein
2018-06-01
Purpose To compare the cost-effectiveness of computed tomographic (CT) colonography and colonoscopy screening by using data on unit costs and participation rates from a randomized controlled screening trial in a dedicated screening setting. Materials and Methods Observed participation rates and screening costs from the Colonoscopy or Colonography for Screening, or COCOS, trial were used in a microsimulation model to estimate costs and quality-adjusted life-years (QALYs) gained with colonoscopy and CT colonography screening. For both tests, the authors determined optimal age range and screening interval combinations assuming a 100% participation rate. Assuming observed participation for these combinations, the cost-effectiveness of both tests was compared. Extracolonic findings were not included because long-term follow-up data are lacking. Results The participation rates for colonoscopy and CT colonography were 21.5% (1276 of 5924 invitees) and 33.6% (982 of 2920 invitees), respectively. Colonoscopy was more cost-effective in the screening strategies with one or two lifetime screenings, whereas CT colonography was more cost-effective in strategies with more lifetime screenings. CT colonography was the preferred test for willingness-to-pay-thresholds of €3200 per QALY gained and higher, which is lower than the Dutch willingness-to-pay threshold of €20 000. With equal participation, colonoscopy was the preferred test independent of willingness-to-pay thresholds. The findings were robust for most of the sensitivity analyses, except with regard to relative screening costs and subsequent participation. Conclusion Because of the higher participation rates, CT colonography screening for colorectal cancer is more cost-effective than colonoscopy screening. The implementation of CT colonography screening requires previous satisfactory resolution to the question as to how best to deal with extracolonic findings. © RSNA, 2018 Online supplemental material is available for this article.
Holt, Cheryl L; Roberts, Chastity; Scarinci, Isabel; Wiley, Shereta R; Eloubeidi, Mohamad; Crowther, Martha; Bolland, John; Litaker, Mark S; Southward, Vivian; Coughlin, Steven S
2009-07-01
This study describes the development of a spiritually based intervention to increase colorectal cancer screening through African American churches by framing the health message with spiritual themes and scripture. The intervention development phase consisted of ideas from an advisory panel and core content identified in focus groups. In the pilot-testing phase, prototypes of the intervention materials were tested for graphic appeal in additional focus groups, and content was tested for acceptability and comprehension in cognitive interviews. Participants preferred materials showing a variety of African Americans in real settings, bright color schemes, and an uplifting message emphasizing prevention and early detection. Spiritual themes such as stewardship over the body, being well to serve God, and using faith to overcome fear, were well received. The materials were then finalized for implementation and will be used by community health advisors to encourage screening.
Screening and Assessment of Kindergarten Children with Developmental Risks.
ERIC Educational Resources Information Center
Moore, C. Rochelle; Sunal, Cynthia S.
This paper reports the implementation of teacher-made, early education screening practices and materials for identifying pre-kindergarten and kindergarten children with developmental risks. A total of 105 children were screened in the spring of 1979 using screening tests devised by the researcher, another kindergarten teacher and a special…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jakubowski, E.M.; Borland, M.M.; Norris, L.
1995-06-01
The U.S. Army Edgewood Research, Development and Engineering Center, the U.S. Army Aberdeen Proving Ground Support Activity, Directorate of Safety, Health and the Environment and SciTech Services Inc., an independent contractor, have developed an approach for screening environmental samples for the presence of chemical warfare agents. Since 1918, the Edgewood area of Aberdeen Proving Ground has been a research and testing ground for toxic agent compounds. Since these materials are considered highly toxic, screening for their presence in environmental samples is necessary for safe shipment to contract laboratories for testing by EPA guidelines. The screening ensures worker safety and maintainsmore » U.S. Army standards for transportation of materials potentially contaminated with chemical warfare agents. This paper describes the screening methodology.« less
NASA Technical Reports Server (NTRS)
Vroman, G. A.
1975-01-01
The capability of shallow-notched, round-bar, tensile specimens for screening critical environments as they affect the material fracture properties of the space shuttle main engine was tested and analyzed. Specimens containing a 0.050-inch-deep circumferential sharp notch were cyclically loaded in a 5000-psi hydrogen environment at temperatures of +70 and -15 F. Replication of test results and a marked change in cyclic life because of temperature variation demonstrated the validity of the specimen type to be utilized for screening tests.
Adaptable Holders for Arc-Jet Screening Candidate Thermal Protection System Repair Materials
NASA Technical Reports Server (NTRS)
Riccio, Joe; Milhoan, Jim D.
2010-01-01
Reusable holders have been devised for evaluating high-temperature, plasma-resistant re-entry materials, especially fabrics. Typical material samples tested support thermal-protection-system damage repair requiring evaluation prior to re-entry into terrestrial atmosphere. These tests allow evaluation of each material to withstand the most severe predicted re-entry conditions.
Reproducibility of polycarbonate reference material in toxicity evaluation
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Huttlinger, P. A.
1981-01-01
A specific lot of bisphenol A polycarbonate has been used for almost four years as the reference material for the NASA-USF-PSC toxicity screening test method. The reproducibility of the test results over this period of time indicate that certain plastics may be more suitable reference materials than the more traditional cellulosic materials.
Two-Piece Screens for Decontaminating Granular Material
NASA Technical Reports Server (NTRS)
Backes, Douglas; Poulter, Clay; Godfrey, Max; Dutton, Melinda; Tolman, Dennis
2009-01-01
Two-piece screens have been designed specifically for use in filtering a granular material to remove contaminant particles that are significantly wider or longer than are the desired granules. In the original application for which the twopiece screens were conceived, the granular material is ammonium perchlorate and the contaminant particles tend to be wires and other relatively long, rigid strands. The basic design of the twopiece screens can be adapted to other granular materials and contaminants by modifying critical dimensions to accommodate different grain and contaminant- particle sizes. A two-piece screen of this type consists mainly of (1) a top flat plate perforated with circular holes arranged in a hexagonal pattern and (2) a bottom plate that is also perforated with circular holes (but not in a pure hexagonal pattern) and is folded into an accordion structure. Fabrication of the bottom plate begins with drilling circular holes into a flat plate in a hexagonal pattern that is interrupted, at regular intervals, by parallel gaps. The plate is then folded into the accordion structure along the gaps. Because the folds are along the gaps, there are no holes at the peaks and valleys of the accordion screen. The top flat plate and the bottom accordion plate are secured within a metal frame. The resulting two-piece screen is placed at the bottom opening of a feed hopper containing the granular material to be filtered. Tests have shown that such long, rigid contaminant strands as wires readily can pass through a filter consisting of the flat screen alone and that the addition of the accordion screen below the flat screen greatly increases the effectiveness of removal of wires and other contaminant strands. Part of the reason for increased effectiveness is in the presentation of the contaminant to the filter surface. Testing has shown that wire type contamination will readily align itself parallel to the material direction flow. Since this direction of flow is nearly always perpendicular to the filter surface holes, the contamination is automatically aligned to pass through. The two-filter configuration reduces the likelihood that a given contaminant strand will be aligned with the flow of material by eliminating the perpendicular presentation angle. Thus, for wires of a certain diameter, a two-piece screen is 20 percent more effective than is the corresponding flat perforated plate alone, even if the holes in the flat plate are narrower. An accordion screen alone is similarly effective in catching contaminants, but lumps of agglomerated granules of the desired material often collect in the valleys and clog the screen. The addition of a flat screen above the accordion screen prevents clogging of the accordion screen. Flat wire screens have often been used to remove contaminants from granular materials, and are about as effective as are the corresponding perforated flat plates used alone.
Rapid bacteriological screening of cosmetic raw materials by using bioluminescence.
Nielsen, P; Van Dellen, E
1989-01-01
Incoming cosmetic raw materials are routinely tested for microbial content. Standard plate count methods require up to 72 h. A rapid, sensitive, and inexpensive raw material screening method was developed that detects the presence of bacteria by means of ATP (bioluminescence). With a 24-h broth enrichment, the minimum bacterial ATP detection threshold of 1 cfu/g sample can be achieved using purified firefly luciferin-luciferase and an ATP releasing reagent. By using this rapid screen, microbiologically free material may be released for production within 24 h, while contaminated material undergoes further quantitative and identification testing. In order for a raw material to be validated for this method it must be evaluated for (1) a potential nonmicrobial light-contributing reaction resulting in a false positive or, (2) degradation of the ATP giving a false negative, and (3) confirmation that the raw material has not overwhelmed the buffering capacity of the enrichment broth. The key criteria for a rapid screen was the sensitivity to detect less than one colony forming unit per g product, the speed to do this within 24 h, and cost efficiency. Bioluminescence meets these criteria. With an enrichment step, it can detect less than one cfu/g sample. After the enrichment step, analysis time per sample is approximately 2 min and the cost for material and reagents is less than one dollar per sample.
Tension fracture of laminates for transport fuselage. Part 1: Material screening
NASA Technical Reports Server (NTRS)
Walker, T. H.; Avery, W. B.; Ilcewicz, L. B.; Poe, C. C., Jr.; Harris, C. E.
1992-01-01
Transport fuselage structures are designed to contain pressure following a large penetrating damage event. Application of composites to fuselage structures requires a data base and supporting analysis on tension damage tolerance. Tests with 430 fracture specimens were used to accomplish the following: (1) identify critical material and laminate variables affecting notch sensitivity, (2) evaluate composite failure criteria, and (3) recommend a screening test method. Variables studied included fiber type, matrix toughness, lamination manufacturing process, and intraply hybridization. The laminates found to have the lowest notch sensitivity were manufactured using automated tow placement. This suggests a possible relationship between the stress distribution and repeatable levels of material inhomogeneity that are larger than found in traditional tape laminates. Laminates with the highest notch sensitivity consisted of toughened matrix materials that were resistant to a splitting phenomena that reduces stress concentrations in load bearing plies. Parameters for conventional fracture criteria were found to increase with the crack length of the smallest notch sizes studied. Most materials and laminate combinations followed less than a square root singularity for the largest crack sizes studied. Specimen geometry, notch type, and notch size were evaluated in developing a screening test procedure. Results indicate that a range of notch sizes must be tested to determine notch sensitivity.
A Screening Test for Wilson's Disease and its Application to Psychiatric Patients
Cox, Diane Wilson
1967-01-01
Varied modes of onset make the early diagnosis of Wilson's disease difficult. A deficiency of serum ceruloplasmin, usually characteristic of the disease, was used as the basis for a screening test. Simple test materials and provision for handling about 50 plasma samples simultaneously made this test feasible for large-scale screening. The screening test was applied to 336 persons hospitalized for psychiatric disorders, to detect patients with Wilson's disease before the classical symptoms appeared. Two patients with ceruloplasmin levels below the normal limits were detected but did not have Wilson's disease. Further application of the screening test to relatives of patients known to have Wilson's disease and to individuals with any symptoms of the disease (hepatic disease, extrapyramidal dysfunction, psychiatric disorders, behaviour problems in children) would aid in early diagnosis and more effective treatment. ImagesFig. 1 PMID:6017170
USDA-ARS?s Scientific Manuscript database
Filter treatment may be a viable means for removing the nitrate, phosphate, and pesticides discharged with agricultural drainage waters that cause adverse environmental impacts within the U.S. on local, regional, and national scales. Laboratory batch test screening for agricultural drainage water ...
Fransen, Mirjam P; Dekker, Evelien; Timmermans, Daniëlle R M; Uiters, Ellen; Essink-Bot, Marie-Louise
2017-02-01
To explore the accessibility of standardized printed information materials of the national Dutch colorectal cancer screening program among low health literate screening invitees and to assess the effect of the information on their knowledge about colorectal cancer and the screening program. Linguistic tools were used to analyze the text and design characteristics. The accessibility, comprehensibility and relevance of the information materials were explored in interviews and in observations (n=25). The effect of the information on knowledge was assessed in an online survey (n=127). The materials employed a simple text and design. However, respondents expressed problems with the amount of information, and the difference between screening and diagnostic follow-up. Knowledge significantly increased in 10 out of 16 items after reading the information but remained low for colorectal cancer risk, sensitivity of testing, and the voluntariness of colorectal cancer screening. Despite intelligible linguistic and design characteristics, screening invitees with low health literacy had problems in accessing, comprehending and applying standard information materials on colorectal cancer screening, and lacked essential knowledge for informed decision-making about participation. To enable equal access to informed decision-making, information strategies need to be adjusted to the skills of low health literate screening invitees. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Salerno-Kochan, R.
2017-10-01
The aim of this paper is to propose the bioindicative measuring method for screening and assessing the safety of textile and leather materials in relation to chemical threats. This method is based on toxicological assay in which Tetrahymena pyriformis, unicellular organism belonging to protozoans, is used as a test organism. For the realization of the research goal the sensitivity threshold of test organisms to chromium(VI) solutions was identified. The changes in cell development of test organisms in chromium solutions were registered by colorimetric measurements in the presence of alamarBlue® cell viability reagent. Empirical data enabled to fit logistic curves on the base of which the level of chromium toxicity was estimated. In the second step, harmfulness of aqueous extracts obtained from textile and leather samples containing chromium in relation to test organisms was evaluated. The performed research confirmed the high efficiency of the proposed method in screening and assessing chromium content in clothes and shoes materials and showed possibilities of using it in safety assessment of products with regard to chemical risks.
NASA Technical Reports Server (NTRS)
Koontz, S. L.; Albyn, K.; Leger, L.
1990-01-01
The use of thermal atom test methods as a materials selection and screening technique for low-earth orbit (LEO) spacecraft is critically evaluated. The chemistry and physics of thermal atom environments are compared with the LEO environment. The relative reactivities of a number of materials determined in thermal atom environments are compared with those observed in LEO and in high-quality LEO simulations. Reaction efficiencies (cu cm/atom) measured in a new type of thermal atom apparatus are one-thousandth to one ten-thousandth those observed in LEO, and many materials showing nearly identical reactivities in LEO show relative reactivities differing by as much as a factor of eight in thermal atom systems. A simple phenomenological kinetic model for the reaction of oxygen atoms with organic materials can be used to explain the differences in reactivity in different environments. Certain speciic thermal atom test environments can be used as reliable materials screening tools.
Code of Federal Regulations, 2012 CFR
2012-04-01
... mass spectrometry is a device that consists of stable isotope internal standards, control materials..., free carnitine, and acylcarnitines using tandem mass spectrometry. 862.1055 Section 862.1055 Food and... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a...
Code of Federal Regulations, 2014 CFR
2014-04-01
... mass spectrometry is a device that consists of stable isotope internal standards, control materials..., free carnitine, and acylcarnitines using tandem mass spectrometry. 862.1055 Section 862.1055 Food and... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a...
Exploratory screening tests of several alloys and coatings for automobile thermal reactors
NASA Technical Reports Server (NTRS)
Oldrieve, R. E.
1971-01-01
A total of 23 materials (including uncoated ferritic and austenitic iron-base alloys, uncoated nickel and cobalt-base superalloys, and several different coatings on AISI 304 stainless steel) were screened as test coupons on a rack in an automobile thermal reactor. Test exposures were generally 51 hours including 142 thermal cycles of 10 minutes at 1010 + or - 30 C test coupon temperature and 7-minutes cool-down to about 510 C. Materials that exhibited corrosion resistance better than that of Hastelloy X include: a ferritic iron alloy with 6 weight percent aluminum; three nickel-base superalloys; two diffused-aluminum coatings on AISI 304; and a Ni-Cr slurry-sprayed coating on AISI 304. Preliminary comparison is made on the performance of the directly impinged coupons and a reactor core of the same material.
Moosberg, Helena; Lagerblad, Björn; Forssberg, Eric
2003-02-01
This investigation has been made in order to make it possible to increase the use of by-products in cement-based materials. Use of by-products requires a screening procedure that will reliably determine their impact on concrete. A test procedure was developed. The most important properties were considered to be strength development, shrinkage, expansion and workability. The methods used were calorimetry, flow table tests, F-shape measurements, measurements of compressive and flexural strength and shrinkage/expansion measurements. Scanning electron microscopy was used to verify some results. Twelve by-products were collected from Swedish metallurgical and mineral industries and classified according to the test procedure. The investigation showed that the test procedure clearly screened out the materials that can be used in the production of concrete from the unsuitable ones.
NASA Technical Reports Server (NTRS)
Koontz, S. L.; Kuminecz, J.; Leger, L.; Nordine, P.
1988-01-01
The use of thermal atom test methods as a materials selection and screening technique for low-Earth orbit (LEO) spacecraft is critically evaluated. The chemistry and physics of thermal atom environments are compared with the LEO environment. The relative reactivities of a number of materials determined to be in thermal atom environments are compared to those observed in LEO and in high quality LEO simulations. Reaction efficiencies measured in a new type of thermal atom apparatus are one-hundredth to one-thousandth those observed in LEO, and many materials showing nearly identical reactivities in LEO show relative reactivities differing by as much as a factor of 8 in thermal atom systems. A simple phenomenological kinetic model for the reaction of oxygen atoms with organic materials can be used to explain the differences in reactivity in different environments. Certain specific thermal test environments can be used as reliable materials screening tools. Using thermal atom methods to predict material lifetime in LEO requires direct calibration of the method against LEO data or high quality simulation data for each material.
Tension fracture of laminates for transport fuselage. Part 1: Material screening
NASA Technical Reports Server (NTRS)
Walker, T. H.; Avery, W. B.; Ilcewicz, L. B.; Poe, C. C., Jr.; Harris, C. E.
1992-01-01
Transport fuselage structures are designed to contain pressure following a large penetrating damage event. Applications of composites to fuselage structures require a database and supporting analysis on tension damage tolerance. Tests with 430 fracture specimens were used to accomplish the following: (1) identify critical material and laminate variables affecting notch sensitivity; (2) evaluate composite failure criteria; and (3) recommend a screening test method. Variables studied included fiber type, matrix toughness, lamination manufacturing process, and intraply hybridization. The laminates found to have the lowest notch sensitivity were manufactured using automated tow placement. This suggests a possible relationship between the stress distribution and repeatable levels of material inhomogeneity that are larger than found in traditional tape laminates. Laminates with the highest notch sensitivity consisted of toughened matrix materials that were resistant to a splitting phenomena that reduces stress concentrations in major load bearing plies. Parameters for conventional fracture criteria were found to increase with crack length for the smallest notch sizes studied. Most material and laminate combinations followed less than a square root singularity for the largest crack sizes studied. Specimen geometry, notch type, and notch size were evaluated in developing a screening test procedure. Traitional methods of correcting for specimen finite width were found to be lacking. Results indicate that a range of notch sizes must be tested to determine notch sensitivity. Data for a single small notch size (0.25 in. diameter) was found to give no indication of the sensitivity of a particular material and laminate layup to larger notch sizes.
Pesticide Program Dialogue Committee - June 5-6, 2014 Materials
This PPDC meeting included sessions on the budget, 21st century toxicity testing, polllinator protection, school IPM, and the endocrine disruptor screening program. View presentation materials for those topics plus other background materials and updates.
Oxygen Compatibility Testing of Composite Materials
NASA Technical Reports Server (NTRS)
Engel, Carl D.; Watkins, Casey N.
2006-01-01
Composite materials offer significant weight-saving potential for aerospace applications in propellant and oxidizer tanks. This application for oxygen tanks presents the challenge of being oxygen compatible in addition to complying with the other required material characteristics. This effort reports on the testing procedures and data obtained in examining and selecting potential composite materials for oxygen tank usage. Impact testing of composites has shown that most of these materials initiate a combustion event when impacted at 72 ft-lbf in the presence of liquid oxygen, though testing has also shown substantial variability in reaction sensitivities to impact. Data for screening of 14 potential composites using the Bruceton method is given herein and shows that the 50-percent reaction frequencies range from 17 to 67 ft-lbf. The pressure and temperature rises for several composite materials were recorded to compare the energy releases as functions of the combustion reactions with their respective reaction probabilities. The test data presented are primarily for a test pressure of 300 psia in liquid oxygen. The impact screening process is compared with oxygen index and autogenous ignition test data for both the composite and the basic resin. The usefulness of these supplemental tests in helping select the most oxygen compatible materials is explored. The propensity for mechanical impact ignition of the composite compared with the resin alone is also examined. Since an ignition-free composite material at the peak impact energy of 72 ft-lbf has not been identified, composite reactivity must be characterized over the impact energy level and operating pressure ranges to provide data for hazard analyses in selecting the best potential material for liquid tank usage.
Evaluation of seven in vitro alternatives for ocular safety testing.
Bruner, L H; Kain, D J; Roberts, D A; Parker, R D
1991-07-01
Seven in vitro assays were evaluated to determine if any were useful as screening procedures in ocular safety assessment. Seventeen test materials (chemicals, household cleaners, hand soaps, dishwashing liquids, shampoos, and liquid laundry detergents) were tested in each assay. In vivo ocular irritation scores for the materials were obtained from existing rabbit low volume eye test (LVET) data. The seven assays evaluated included the silicon microphysiometer (SM), luminescent bacteria toxicity test (LBT), neutral red assay (NR), total protein assay (TP), Tetrahymena thermophila motility assay (TTMA), bovine eye/chorioallantoic membrane assay (BE/CAM), and the EYTEX system (ETS). For the seventeen materials used in this study there was a significant correlation between the in vivo irritant potential and in vitro data for all the tests except the EYTEX System (SM, r = -0.87; LBT, r = -0.91; NR, r = -0.85; TTMA, r = 0.78; TP, r = -0.86; ETS, r = 0.29). The irritation classifications provided by the BE/CAM also did not correspond with the actual in vivo irritancy potential of the test materials. The result of this study suggested it may be possible to classify materials into broad irritancy categories with some of the assays. This would allow their use as screens prior to limited in vivo confirmation in the ocular safety assessment process.
Materials screening tests for the krypton-85 storage development program
NASA Astrophysics Data System (ADS)
Nagata, P. K.
1981-04-01
The results of a materials testing program for krypton-85 storage techniques are reported. Corrosion and stress corrosion tests were performed on a variety of materials including AISI 4130, Type 316 SS, Type 304 SS, Type 310 SS, Nitronic 50, and alloy A286. Test environments were high-purity liquid rubidium, liquid rubidium contaminated with oxygen, and rubidium hydroxide. Oxygen and water contaminations in liquid rubidium were found to greatly increase both general and localized corrosion of the materials tested. Alloy A286, Type 304 SS, and AISI 4130 were eliminated as candidate materials due to their susceptibility to general corrosion and stress corrosion cracking.
Single-Cycle Versus Multicycle Proof Testing
NASA Technical Reports Server (NTRS)
Hudak, S. J., Jr.; Mcclung, R. C.; Bartlett, M. L.; Fitzgerald, J. H.; Russell, D. A.
1992-01-01
Report compares single-cycle with multiple-cycle mechanical-stress tests of parts under mechanical stresses. Objective of proof testing: to screen out gross manufacturing or material deficiencies and provide additional assurance of quality. Report concludes that changes in distribution of crack sizes during multicycle proof testing depend on initial distribution, number of cycles, relationship between resistance of material and elastic/plastic fracture-mechanics parameter, relationship between load control and displacement control, and magnitude of applied load or displacement. Whether single-cycle or multicycle testing used depends on shape, material, and technique of fabrication of components tested.
Ford, Loretta T; Berg, Jonathan D
2017-03-01
Introduction Legal highs also known as novel psychoactive substances mimic the effects of classic drugs of abuse. Challenges to developing screening services for novel psychoactive substances include identifying which novel psychoactive substances are available to target. Using new techniques such as exact mass time of flight can help identify common novel psychoactive substances to target for screening patient samples by routine methods such as tandem mass spectrometry. We demonstrate this strategy working in our own clinical toxicology laboratory after qualitative analysis of 98 suspect materials for novel psychoactive substances by ultra-performance liquid chromatography with time of flight mass spectrometry. Results From July 2014 to July 2015 we received 98 requests to test a range of different suspect materials for novel psychoactive substances including herbs, tobacco, liquids, pills and powders. Overall, 87% of the suspect materials tested positive for novel psychoactive substances, and 15% for controlled drugs. Three common novel psychoactive substances were present in 74% of the suspect materials: methiopropamine, a methamphetamine analogue; ethylphenidate, a cocaine mimic; and the third generation synthetic cannabinoid 5F-AKB-48. For the 55 branded products we tested only 24% of the stated contents matched exactly the compounds we detected. Conclusion Testing suspect materials using ultra-performance liquid chromatography with time of flight mass spectrometry has identified three common novel psychoactive substances in use in the UK, simplifying the development of a relevant novel psychoactive substances screening service to our population. By incorporating this into our routine liquid chromatography tandem mass spectrometry drugs of abuse screen, then offers a clinically relevant novel psychoactive substances service to our users. This strategy ensures our clinical toxicology service continues to remain effective to meet the challenges of the changing drug use in the UK.
Photothermal characterization of encapsulant materials for photovoltaic modules
NASA Technical Reports Server (NTRS)
Liang, R. H.; Gupta, A.; Distefano, S.
1982-01-01
A photothermal test matrix and a low cost testing apparatus for encapsulant materials of photovoltaic modules were defined. Photothermal studies were conducted to screen and rank existing as well as future encapsulant candidate materials and/or material formulations in terms of their long term physiochemical stability under accelerated photothermal aging conditions. Photothermal characterization of six candidate pottant materials and six candidate outer cover materials were carried out. Principal products of photothermal degradation are identified. Certain critical properties are also monitored as a function of photothermal aging.
21 CFR 862.1660 - Quality control material (assayed and unassayed).
Code of Federal Regulations, 2010 CFR
2010-04-01
... includes controls (assayed and unassayed) for blood gases, electrolytes, enzymes, multianalytes (all kinds...). Except when used in donor screening tests, unassayed material is exempt from the premarket notification...
Laypersons' views of material incentives for enhancing colorectal cancer screening.
Hagoel, Lea; Rennert, Gad; Feder-Bubis, Paula
2015-10-01
Colorectal cancer (CRC) early detection improves health outcomes; screening programmes invest efforts in initiating invitations to target populations to be tested. Enhanced adherence is essential for reduction of morbidity and mortality. Participation rates in Israel are still relatively low. To explore lay views regarding the concept of receiving material incentives in exchange for enhanced adherence to CRC screening. Qualitative study. Between November 2009 and February 2010 six focus group discussions were carried out in two urban, middle and low socio-economic status primary care clinics in a Northern city in Israel. Participants were eligible individuals for CRC screening, aged 50-68 (N = 24). Data analysis followed the principles of grounded theory, supported by qualitative software. Participants found administering incentives in exchange for CRC screening inappropriate on rational and moral grounds. They valued their relations with the medical team and the health system more than the potential gain expected. Individuals eligible for CRC screening perceived themselves as responsible for their health, admitting difficulties in realizing this responsibility. Incentives were reported unsuitable for solving reported screening difficulties and a potential harm to the doctor-patient relationship. Focus group participants expressed an unconventional voice towards the use of material incentives. They pointed to the need for focused support of health behaviour change and valued their autonomy. While a proportion of the invitees in the target population see the importance of screening and appreciate the HMO's initiative to invite them for testing, they also expressed their need for support from the HMO in realizing the recommended health behaviour. © 2013 John Wiley & Sons Ltd.
Materials for Space Exploration
NASA Technical Reports Server (NTRS)
Robertson, Luke B.; Williams, Martha
2010-01-01
Topics include a lab overview, testing and processing equipment, hemochromic hydrogen sensors, antimicrobial materials, wire system materials, CNT ink formulations, CNT ink dust screens, CNT ink printed circuitry, cryogenic materials development, fire and polymers, the importance of lighting, electric lighting systems, LED for plant growth, and carbon nanotube fiber filaments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Twieg, R.J.
Materials were chosen by screening the Cambridge Crystallographic Index for new noncentrosymmetric crystalline compounds, by screening commercially available materials or by synthesis of unique new substances. Measurements were then made on the powder form of these materials. Langmuir-Blodgett films were deposited and studied. In addition to the above studies, a computer program was developed to calculate (hyper) polarizabilities of organic molecules and thus aid in the selection of materials for testing. The nonlinear molecules have been divided into three classes according to absorption cutoff: 400 to 500 nm, 300 to 400 nm, and 200 to 300 nm. 108 refs., 7more » tabs. (WRF)« less
Development of zinc-plated regenerator material
NASA Astrophysics Data System (ADS)
Y Xu, M.; Morie, T.; Tsuchiya, A.
2017-12-01
An effective way to improve the efficiency of a cryocooler is to improve the efficiency of the regenerator. In general, the heat capacity of materials decreases as temperature decreases. Thus, when temperature is below 40 K, lead or bismuth spheres are often used as regenerator materials. However, the pressure drop in a sphere regenerator is much larger than that in a screen regenerator. To overcome this dilemma, Xu et al. reported that cooling performance at the temperature of less than 40 K was improved when using tin-plated screens at the cold end of the regenerator. However, the reliability of tin at low temperatures is still not verified fully because of its phase transition from a normal β phase to an abnormal α phase, which may result in a significant reduction of the mechanical strength. In this paper, a zinc-plated screen is proposed as another potential alternative. A comparison test was performed with a two-stage GM cryocooler by replacing part of the first stage regenerator material, phosphorus bronze screens, with zinc-plated screens. Compared to a regenerator filled with bronze screens, the cooling capacity of the first stage increased by about 11% at 40 K and 60% at 30 K with these zinc-plated screens. The detailed experimental results are reported in this paper.
NASA Astrophysics Data System (ADS)
Beaumont, Robert
Currently, there are no reliable methods for screening potential armour materials and hence full-scale ballistic trials are needed. These are both costly and time-consuming in terms of the actual test and also in the materials development that needs to take place to produce sufficient material to give a meaningful result. Whilst it will not be possible to dispense with ballistic trials before material deployment in armour applications, the ability to shorten the development cycle would be advantageous. The thermal shock performance of ceramic armour materials has been highlighted as potential marker for ballistic performance. Hence the purpose of this study was to investigate this further. A new thermal shock technique that reproduced features relevant to ballistic testing was sought. As it would be beneficial to have a simple test that did not use much material, a water-drop method was adopted. This was combined with a variety of characterisation techniques, administered pre- and post-shock. The methods included measurement of the amplitude of ultrasonic wave transmission through the sample alongside residual strength testing using a biaxial ball-on-ball configuration and reflected light and confocal microscopy. Once the protocols had been refined the testing regime was applied to a group of ceramic materials. The materials selected were from two broad groups: alumina and carbide materials. Carbide ceramics show superior performance to alumina ceramics in ballistic applications so it was essential that any screening test would be easily able to differentiate the two groups. Within the alumina family, two commercially available materials, AD995 and Sintox FA, were selected. These were tested alongside three developmental silicon carbide-boron carbide composites, which had identical chemical compositions but different microstructures and thus presented more of a challenge in terms of differentiation. The results from the various tests were used to make predictions about the relative ballistic performances. The tests showed that all of the composites would outperform the alumina materials. Further, all of the tests led to the prediction that AD995 would be better ballistically than Sintox FA, possibly up to a factor of two better. The predictions were in very good agreement with literature values for depth-of-penetration testing. The situation was more complex for the carbide materials, with different tests leading to slightly different predictions. However, the predictions from the ultrasonic tests were consistent with the available ballistic data. Indeed, the ultrasonic data proved to be the most consistent predictor of ballistic performance, supporting the view that the total defect population is more relevant than a ‘critical flaw’ concept. Thus, it can be concluded that with further development, and subject to validation across a wider spread of materials and microstructures, thermal shock testing coupled with ultrasonic measurements could form the basis of a future screening test for ceramics for armour applications.
Evaluation of heat- and blast-protection materials
NASA Technical Reports Server (NTRS)
Morrison, J. D.; Lockhart, B. J.
1971-01-01
A program was initiated at the Kennedy Space Center in December 1967 and conducted through December 1969 to evaluate the performance of heat- and blast-protection materials for ground support equipment used during the Apollo/Saturn launches. Materials believed to be generally suitable for heat and blast protection were subjected to launch-exposure tests. Tests were made during the Apollo/Saturn 502, 503, and 505 launches. Tests were also made in a local laboratory, as an alternative to the restrictive requirements of launch-exposure tests, to determine the effects of torch-flame exposure on ablative materials. Five materials were found to be satisfactory in all major test categories. It was determined that torch-flame tests can probably be utilized as an acceptable substitute for the booster-engine-exhaust exposure tests for basic screening of candidate materials.
Post-Test Analysis of the Deep Space One Spare Flight Thruster Ion Optics
NASA Technical Reports Server (NTRS)
Anderson, John R.; Sengupta, Anita; Brophy, John R.
2004-01-01
The Deep Space 1 (DSl) spare flight thruster (FT2) was operated for 30,352 hours during the extended life test (ELT). The test was performed to validate the service life of the thruster, study known and identify unknown life limiting modes. Several of the known life limiting modes involve the ion optics system. These include loss of structural integrity for either the screen grid or accelerator grid due to sputter erosion from energetic ions striking the grid, sputter erosion enlargement of the accelerator grid apertures to the point where the accelerator grid power supply can no longer prevent electron backstreaming, unclearable shorting between the grids causes by flakes of sputtered material, and rouge hole formation due to flakes of material defocusing the ion beam. Grid gap decrease, which increases the probability of electron backstreaming and of arcing between the grids, was identified as an additional life limiting mechanism after the test. A combination of accelerator grid aperture enlargement and grid gap decrease resulted in the inability to prevent electron backstreaming at full power at 26,000 hours of the ELT. Through pits had eroded through the accelerator grid webbing and grooves had penetrated through 45% of the grid thickness in the center of the grid. The upstream surface of the screen grid eroded in a chamfered pattern around the holes in the central portion of the grid. Sputter deposited material, from the accelerator grid, adhered to the downstream surface of the screen grid and did not spall to form flakes. Although a small amount of sputter deposited material protruded into the screen grid apertures, no rouge holes were found after the ELT.
ERIC Educational Resources Information Center
Brouwer, Henry
2005-01-01
A simple procedure to quickly screen different consumer products for the presence of lead, cadmium, and other metals is described. This screening technique avoids expending a lot of preparation time on samples known to contain low levels of hazardous metals where only samples testing positive for the desired elements need to be analyzed…
Bisphenol A polycarbonate as a reference material
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Cumming, H. J.; Williams, J. B.
1977-01-01
Test methods require reference materials to standardize and maintain quality control. Various materials have been evaluated as possible reference materials, including a sample of bisphenol A polycarbonate without additives. Screening tests for relative toxicity under various experimental conditions were performed using male mice exposed to pyrolysis effluents over a 200-800 C temperature range. It was found that the bisphenol A polycarbonate served as a suitable reference material as it is available in large quantities, and does not significantly change with time.
On the Use of Accelerated Aging Methods for Screening High Temperature Polymeric Composite Materials
NASA Technical Reports Server (NTRS)
Gates, Thomas S.; Grayson, Michael A.
1999-01-01
A rational approach to the problem of accelerated testing of high temperature polymeric composites is discussed. The methods provided are considered tools useful in the screening of new materials systems for long-term application to extreme environments that include elevated temperature, moisture, oxygen, and mechanical load. The need for reproducible mechanisms, indicator properties, and real-time data are outlined as well as the methodologies for specific aging mechanisms.
Acoustic emission as a screening tool for ceramic matrix composites
NASA Astrophysics Data System (ADS)
Ojard, Greg; Goberman, Dan; Holowczak, John
2017-02-01
Ceramic matrix composites are composite materials with ceramic fibers in a high temperature matrix of ceramic or glass-ceramic. This emerging class of materials is viewed as enabling for efficiency improvements in many energy conversion systems. The key controlling property of ceramic matrix composites is a relatively weak interface between the matrix and the fiber that aids crack deflection and fiber pullout resulting in greatly increased toughness over monolithic ceramics. United Technologies Research Center has been investigating glass-ceramic composite systems as a tool to understand processing effects on material performance related to the performance of the weak interface. Changes in the interface have been shown to affect the mechanical performance observed in flexural testing and subsequent microstructural investigations have confirmed the performance (or lack thereof) of the interface coating. Recently, the addition of acoustic emission testing during flexural testing has aided the understanding of the characteristics of the interface and its performance. The acoustic emission onset stress changes with strength and toughness and this could be a quality tool in screening the material before further development and use. The results of testing and analysis will be shown and additional material from other ceramic matrix composite systems may be included to show trends.
Analysis of aquifer tests in the Punjab region of West Pakistan
Bennett, Gordon D.; ,; Sheikh, Ijaz Ahmed; Alr, Sabire
1967-01-01
The results of 141 pumping tests in the Punjab Plain of West Pakistan are reported. Methods of test analysis are described in detail, and an outline of the theory underlying these methods is given. The lateral permeability of the screened interval is given for all tests; the specific yield of the material at water-table depth is given for 1(6 tests; and the vertical permeability of the material between the water table and the top of the screen is given for 14 tests. The lateral permeabilities are predominantly in the range 0.001 to 0.006 cfs per sq ft; the average value is 0.0032 cfs per sq ft. Specific yields generally range from 0.02 to 0.26; the average value is 0.14. All vertical permeability results fall in the range 10 -5 to 10 -3 cfs per sq ft.
NASA Technical Reports Server (NTRS)
Olson, S. L.; Beeson, H. D.; Haas, J. P.; Baas, J. S.
2004-01-01
The objective of this research is to modify the well-instrumented standard cone configuration to provide a reproducible bench-scale test environment that simulates the buoyant or ventilation flow that would be generated by or around a burning surface in a spacecraft or extraterrestrial gravity level. We will then develop a standard test method with pass-fail criteria for future use in spacecraft materials flammability screening. (For example, dripping of molten material will be an automatic fail.)
Advanced Stirling receiver development program, phase 1
NASA Technical Reports Server (NTRS)
Lurio, Charles A.
1990-01-01
Critical technology experiments were designed and developed to evaluate the Stirling cavity heat pipe receiver for a space solar power system. Theoretical criteria were applied to the design of a module for containing energy storage phase change material while avoiding thermal ratcheting. Zero-g drop tower tests, without phase change, were conducted to affirm that the bubble location required to avoid ratcheting could be achieved without the use of container materials that are wetted by the phase change material. A full scale module was fabricated, but not tested. A fabrication method was successfully developed for the sodium evaporator dome, with a sintered screen wick, to be used as the focal point for the receiver. Crushing of the screen during hydroforming was substantially reduced over the results of other researchers by using wax impregnation. Superheating of the sodium in the wick under average flux conditions is expected to be under 10K. A 2000K furnace which will simulate solar flux conditions for testing the evaporator dome was successfully built and tested.
A systematic analysis of online marketing materials used by providers of expanded carrier screening.
Chokoshvili, Davit; Borry, Pascal; Vears, Danya F
2017-12-14
PurposeExpanded carrier screening (ECS) for a large number of recessive disorders is available to prospective parents through commercial providers. This study aimed to analyze the content of marketing materials on ECS providers' websites.MethodsTo identify providers of ECS tests, we undertook a comprehensive online search, reviewed recent academic literature on commercial carrier screening, and consulted with colleagues familiar with the current ECS landscape. The identified websites were archived in April 2017, and inductive content analysis was performed on website text, brochures and educational materials, and video transcripts.ResultsWe identified 18 ECS providers, including 16 commercial genetic testing companies. Providers typically described ECS as an important family planning tool. The content differed in both the tone used to promote ECS and the accuracy and completeness of the test information provided. We found that most providers offered complimentary genetic counseling to their consumers, although this was often optional, limited to the posttest context, and, in some cases, appeared to be available only to test-positive individuals.ConclusionThe quality of ECS providers' websites could be improved by offering more complete and accurate information about ECS and their tests. Providers should also ensure that all carrier couples receive posttest genetic counseling to inform their subsequent reproductive decision making.Genet Med advance online publication, 14 December 2017; doi:10.1038/gim.2017.222.
Holt, Cheryl L; Wynn, Theresa A; Southward, Penny; Litaker, Mark S; Jeames, Sanford; Schulz, Emily
2009-09-01
One way of developing culturally relevant health communication in the African American church setting is to develop spiritually based interventions, in which the health message is framed by relevant spiritual themes and scripture. In this article we describe the development of a community health advisor(CHA)-led intervention aimed at increasing informed decision making (IDM) for prostate cancer screening among church-attending African American men. Full-color print educational booklets were developed and pilot tested with extensive community participation of church-attending African American men age-eligible for screening. The intervention development phase consisted of ideas solicited from an advisory panel of African American men (N = 10), who identified core content and developed the spiritual themes. In the intervention pilot testing phase, prototypes of the intervention materials were pilot tested for graphic appeal in two focus groups (N = 16), and content was tested for acceptability and comprehension using individual cognitive response interviews (N = 10). Recommendations were made for project branding and logo and for use of graphics of real people in the educational materials. Significant feedback was obtained from the focus groups, on the graphics, colors, fonts, continuity, titles, and booklet size/shape. The importance of working closely with the community when developing interventions is discussed, as well as the importance of pilot testing of educational materials.
Balasubramanian, Akhila; Kulasingam, Shalini L.; Baer, Atar; Hughes, James P.; Myers, Evan R.; Mao, Constance; Kiviat, Nancy B.; Koutsky, Laura A.
2010-01-01
Objective Estimate the accuracy and cost-effectiveness of cervical cancer screening strategies based on high-risk HPV DNA testing of self-collected vaginal samples. Materials and Methods A subset of 1,665 women (18-50 years of age) participating in a cervical cancer screening study were screened by liquid-based cytology and by high-risk HPV DNA testing of both self-collected vaginal swab samples and clinician-collected cervical samples. Women with positive/abnormal screening test results and a subset of women with negative screening test results were triaged to colposcopy. Based on individual and combined test results, five screening strategies were defined. Estimates of sensitivity and specificity for cervical intraepithelial neoplasia grade 2 or worse were calculated and a Markov model was used to estimate the incremental cost-effectiveness ratios (ICERs) for each strategy. Results Compared to cytology-based screening, high-risk HPV DNA testing of self-collected vaginal samples was more sensitive (68%, 95%CI=58%-78% versus 85%, 95%CI=76%-94%) but less specific (89%, 95%CI=86%-91% versus 73%, 95%CI=67%-79%). A strategy of high-risk HPV DNA testing of self-collected vaginal samples followed by cytology triage of HPV positive women, was comparably sensitive (75%, 95%CI=64%-86%) and specific (88%, 95%CI=85%-92%) to cytology-based screening. In-home self-collection for high-risk HPV DNA detection followed by in-clinic cytology triage had a slightly lower lifetime cost and a slightly higher quality-adjusted life expectancy than did cytology-based screening (ICER of triennial screening compared to no screening was $9,871/QALY and $12,878/QALY, respectively). Conclusions Triennial screening by high-risk HPV DNA testing of in-home, self-collected vaginal samples followed by in-clinic cytology triage was cost-effective. PMID:20592553
NASA Astrophysics Data System (ADS)
Kagawa, Hideshi; Fujii, Go; Kajiwara, Kenichi; Kuroda, Daisuke; Suzuki, Takuya; Yamabe-Mitarai, Yoko; Murakami, Hideyuki; Ono, Yoshinori
2012-07-01
Haynes25 (L-605) is a common heat resistant alloy used in mono-propellant structures and screen materials for catalyst beds. The lifetime requirements for thrusters have expanded dramatically after studies conducted in the 1970s on mono-propellant materials used to extend the service life. The material design had long remained unchanged, and the L-605 was still used as thruster material due to its good heritage. However, some important incidents involving degradation were found during the test-unit break-up inspection following the thruster life tests. The Japanese research team focused on the L-605 degradations found on the catalyst bed screen mesh used for mono-propellant thruster and analysed the surface of the wire material and the cross- section of the wire screen mesh used in the life tests. The investigation showed that the degradation was caused by nitriding L-605 component elements. The team suggested that the brittle fracture was attributable to tungsten (W) carbides, which formed primarily in the grain boundaries, and chromium (Cr) nitride, which formed mainly in the parts in contact with the hot firing gas. The team also suggested the installation of a platinum coating on the material surface as a countermeasure L-605 nitric degradation. Inconel 625 is now selected as a mono-propellant structure material due to its marginal raw material characters and cost. The team believes that Inconel 625 does not form W carbides since it contains no tungsten component, but does contain Cr and Fe, which form nitrides easily. Therefore, the team agreed that for the Inconel 625, there was a need to evaluate changes in the microstructure and mechanical properties following exposure to hot nitrogen gases. This paper will describe these changes of Inconel 625.
Combinatorial and high-throughput screening of materials libraries: review of state of the art.
Potyrailo, Radislav; Rajan, Krishna; Stoewe, Klaus; Takeuchi, Ichiro; Chisholm, Bret; Lam, Hubert
2011-11-14
Rational materials design based on prior knowledge is attractive because it promises to avoid time-consuming synthesis and testing of numerous materials candidates. However with the increase of complexity of materials, the scientific ability for the rational materials design becomes progressively limited. As a result of this complexity, combinatorial and high-throughput (CHT) experimentation in materials science has been recognized as a new scientific approach to generate new knowledge. This review demonstrates the broad applicability of CHT experimentation technologies in discovery and optimization of new materials. We discuss general principles of CHT materials screening, followed by the detailed discussion of high-throughput materials characterization approaches, advances in data analysis/mining, and new materials developments facilitated by CHT experimentation. We critically analyze results of materials development in the areas most impacted by the CHT approaches, such as catalysis, electronic and functional materials, polymer-based industrial coatings, sensing materials, and biomaterials.
NASA Astrophysics Data System (ADS)
Zhang, Ruizhi; Du, Baoli; Chen, Kan; Reece, Mike; Materials Research Insititute Team
With the increasing computational power and reliable databases, high-throughput screening is playing a more and more important role in the search of new thermoelectric materials. Rather than the well established density functional theory (DFT) calculation based methods, we propose an alternative approach to screen for new TE materials: using crystal structural features as 'descriptors'. We show that a non-distorted transition metal sulphide polyhedral network can be a good descriptor for high power factor according to crystal filed theory. By using Cu/S containing compounds as an example, 1600+ Cu/S containing entries in the Inorganic Crystal Structure Database (ICSD) were screened, and of those 84 phases are identified as promising thermoelectric materials. The screening results are validated by both electronic structure calculations and experimental results from the literature. We also fabricated some new compounds to test our screening results. Another advantage of using crystal structure features as descriptors is that we can easily establish structural relationships between the identified phases. Based on this, two material design approaches are discussed: 1) High-pressure synthesis of metastable phase; 2) In-situ 2-phase composites with coherent interface. This work was supported by a Marie Curie International Incoming Fellowship of the European Community Human Potential Program.
Deciding on PSA-screening - Quality of current consumer information on the Internet.
Korfage, Ida J; van den Bergh, Roderick C N; Essink-Bot, Marie-Louise
2010-11-01
Given that screening for prostate cancer has the potential to reduce prostate cancer mortality at the expense of considerable overdiagnosis and overtreatment, the availability of core consumer information - correct, balanced and supportive of autonomous decision-making - is a must. We assessed the quality of consumer information available through the Internet per November 2009 and its possible contribution to informed decision-making by potential screenees. Consumer information on PSA-screening was sought through the Internet in November 2009. Materials had to be targeted at potential consumers, offered by not-for-profit organisations, released in 2005 or after, in English or Dutch. Per material 2 of the authors assessed independently from each other whether standardised pre-defined topics were addressed, whether the content was correct and which approach was taken towards the decision-making process about uptake. Twenty-three materials were included, of which 11 were released (shortly) after the results of 2 large randomized-controlled trials (RCTs) that evaluated the effectiveness of screening for prostate cancer had been published in March 2009. That a PSA-test result can be abnormal because of non-cancerous conditions (false positive) and that it may miss prostate cancer (false negative) was not addressed in 2/23 and 8/23 materials, respectively. The risk of overdiagnosis and overtreatment was not mentioned in 6 out of 23. PSA-screening was presented as a usual thing to do in some materials, whereas other materials emphasised the voluntary nature of PSA-screening ('it is your decision'). The content of 19/23 materials was considered sufficiently informative according to the pre-defined criteria, 12/23 materials were considered supportive of informed decision-making by men. Most materials of not-for-profit organizations supplied adequate information about PSA-screening, whilst the degree of persuasion towards uptake reflected variations in opinions on men's autonomy regarding their own health. Copyright © 2010 Elsevier Ltd. All rights reserved.
Methane production and hydrolysis kinetics in the anaerobic degradation of wastewater screenings.
Cadavid-Rodríguez, L S; Horan, N
2013-01-01
Anaerobic biodegradability and hydrolysis rates of wastewater screenings were determined using the biochemical methane potential test at 37 °C. The extent and rate of screenings conversion to methane of this complex and particulate substrate were investigated and since two stages of hydrolysis were identified, corresponding to the different types of materials in screenings, a linear and non-linear model was used. No accumulation of intermediary products was observed and so it was possible to use the methane production rate and a linear model to estimate the hydrolysis rate in the first phase of hydrolysis. The measured values of 0.061-0.127 d(-1) are in the range reported for other comparable organic wastes. It was also observed that the inoculum-to-substrate ratio has a large impact on methane production rate of screenings. The difference in biodegradation rates from the materials in screenings and the overall hydrolysis could be represented by the modified Gompertz non-linear model which was able to describe the methane production rate of screenings with a high confidence. Screenings were found to have 52% biodegradability on average and this shows the potential for volatile solids destruction. A two-stage process with an improved hydrolysis rate is proposed to ensure that the full potential of the material is exploited.
Evaluation of the smoke density chamber as an apparatus for fire toxicity screening tests
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Labossiere, L. A.
1976-01-01
The smoke density chamber is perhaps the most widely used apparatus for smoke measurements. Because of its availability, it has been proposed as an apparatus for evaluating fire toxicity. The standard apparatus and procedure were not found suitable for toxicity screening tests using laboratory animals, because not enough materials of interest produced animal mortality or even incapacitation under standard test conditions. With modifications, the chamber offers greater promise as a screening tool, but other tests specifically designed to measure relative toxicity may be more cost-effective. Where one-dimensional heat flux is a requirement, the chamber is the most suitable apparatus available. It should be improved in regard to visibility of animals and ease of cleaning.
NASA Technical Reports Server (NTRS)
Yen, Judy C. H.; Tomsik, Thomas M.
2004-01-01
This paper describes the results of a series of catalyst screening tests conducted with Jet-A fuel under auto-thermal reforming (ATR) process conditions at the research laboratories of SOFCo-EFS Holdings LLC under Glenn Research Center Contract. The primary objective is to identify best available catalysts for future testing at the NASA GRC 10-kW(sub e) reformer test facility. The new GRC reformer-injector test rig construction is due to complete by March 2004. Six commercially available monolithic catalyst materials were initially selected by the NASA/SOFCo team for evaluation and bench scale screening in an existing 0.05 kW(sub e) microreactor test apparatus. The catalyst screening tests performed lasted 70 to 100 hours in duration in order to allow comparison between the different samples over a defined range of ATR process conditions. Aging tests were subsequently performed with the top two ranked catalysts as a more representative evaluation of performance in a commercial aerospace application. The two catalyst aging tests conducted lasting for approximately 600 hours and 1000 hours, respectively.
ERIC Educational Resources Information Center
Baldwin, Cynthia A.
This study determined, by means of a random sample, how many of Colorado's public schools have asbestos materials and estimated the potential risk of exposure presented by these materials. Forty-one schools were surveyed. Bulk samples of possible asbestos materials were collected and analyzed using the K-squared Asbestos Screening Test to…
Materials Compatibility Testing in Concentrated Hydrogen Peroxide
NASA Technical Reports Server (NTRS)
Boxwell, R.; Bromley, G.; Mason, D.; Crockett, D.; Martinez, L.; McNeal, C.; Lyles, G. (Technical Monitor)
2000-01-01
Materials test methods from the 1960's have been used as a starting point in evaluating materials for today's space launch vehicles. These established test methods have been modified to incorporate today's analytical laboratory equipment. The Orbital test objective was to test a wide range of materials to incorporate the revolution in polymer and composite materials that has occurred since the 1960's. Testing is accomplished in 3 stages from rough screening to detailed analytical tests. Several interesting test observations have been made during this testing and are included in the paper. A summary of the set-up, test and evaluation of long-term storage sub-scale tanks is also included. This sub-scale tank test lasted for a 7-month duration prior to being stopped due to a polar boss material breakdown. Chemical evaluations of the hydrogen peroxide and residue left on the polar boss surface identify the material breakdown quite clearly. The paper concludes with recommendations for future testing and a specific effort underway within the industry to standardize the test methods used in evaluating materials.
Determining knowledge and behaviour change after nutrition screening among older adults.
Southgate, Katherine M; Keller, Heather H; Reimer, Holly D
2010-01-01
Two education interventions involving personalized messages after nutrition screening in older adults were compared to determine changes in nutrition knowledge and risk behaviour. Of 150 older adults randomly selected from a local seniors' centre, 61 completed baseline screening and a demographic and nutrition knowledge questionnaire and were randomized to one of two groups. Group A received personalized letters plus an educational booklet, and Group B received personalized letters only. All materials were sent through the mail. Forty-four participants completed post-test questionnaires to determine change in knowledge and risk behaviour. Both groups had reduced nutrition risk scores and increased knowledge scores at post-test. After the intervention, a significant difference was observed in knowledge change by treatment group. Group A participants experienced greater gains in knowledge, with a mean gain of 5.43 points, than did those in Group B, who had a mean gain of 1.36 points (p=0.018). Screening and education with print materials have the potential to change risk behaviour and nutrition knowledge in older adults. A specially designed booklet on older adults' nutrition risk factors plus a personalized letter provide an effective education strategy for older adults after screening.
Studies with the USF/NASA toxicity screening test method - Exercise wheels and oxygen replenishment
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Cumming, H. J.
1977-01-01
Continuing efforts to improve the University of San Francisco/NASA toxicity screening test method have included the addition of exercise wheels to provide a different measure of incapacitation, and oxygen replenishment to offset any effect of oxygen depletion by the test animals. The addition of exercise wheels limited the number of animals in each test and doubled the required number of tests without any significant improvement in reproducibility. Oxygen replenishment appears to have an effect on survival in the last 5 minutes of the 30-minute test, but the effect is expected to be similar for most materials.
Ceramic regenerator systems development program
NASA Technical Reports Server (NTRS)
Cook, J. A.; Fucinari, C. A.; Lingscheit, J. N.; Rahnke, C. J.; Rao, V. D.
1978-01-01
Ceramic regenerator cores are considered that can be used in passenger car gas turbine engines, Stirling engines, and industrial/truck gas turbine engines. Improved materials and design concepts aimed at reducing or eliminating chemical attack were placed on durability tests/in industrial gas turbine engines. A regenerator core made from aluminum silicate shows minimal evidence of chemical attack damage after 7804 hours of engine test at 800 C and another showed little distress after 4983 hours at 982 C. The results obtained in ceramic material screening tests, aerothermodynamic performance tests, stress analysis, cost studies, and material specifications are also included.
Remediation of AMD using natural and waste material
NASA Astrophysics Data System (ADS)
Basir, Nur Athirah Mohamad; Yaacob, Wan Zuhairi Wan
2014-09-01
Acid Mine Drainage (AMD) is highly acidic, sulphate rich and frequently carries a high transition metal and heavy metal burden. These AMD's eventually migrate into streams and rivers and impact negatively on the quality of these water bodies. So it is dire necessary to treat this AMD. Various materials such as ladle furnace slag (LFS), bentonite, zeolite, active carbon and kaolinite are currently available to remove heavy metals from contaminated water. All these materials are capable to rise up the pH value and adsorb heavy metals. The process is divided into two stages; screening test and tank experiment. Screening test is conduct by using Batch Equilibrium Test (BET), X-Ray Fluorescene (XRF) identification also Scanning Electron Microscopic (SEM) characteristic. The results showed that all the concentration of heavy metal are decreasing extremely and pH value rise up except for kaolinite. From screening test only ladle furnace slag, bentonite, zeolite and active carbon are chosen for the tank experiment. Tank experiment design with 18cm (H) X 15cm (L) X 15cm (H) was made by silica glass. All these treatment materials were stirred in the tank for 30 days. Initial pH for all tanks is 2.4 and after 30 days is changing into 6.11, 3.91, 2.98 and 2.71 for LFS, bentonite, active carbon as well as zeolite respectively. LFS is the best material for absorption of Zn, Mn and Cu in the synthetic solution. Meanwhile, bentonite is the best absorbent for Ni, Fe and Cd. The conclusion shows that LFS might have big potentials to control AMD pollution base on neutralize pH resulting in a great improvement in the quality of the water.
Corrosion testing of candidates for the alkaline fuel cell cathode
NASA Technical Reports Server (NTRS)
Singer, Joseph; Fielder, William L.
1989-01-01
Current/voltage data was obtained for specially made corrosion electrodes of some oxides and of gold materials for the purpose of developing a screening test of catalysts and supports for use at the cathode of the alkaline fuel cell. The data consists of measurements of current at fixed potentials and cyclic voltammograms. These data will have to be correlated with longtime performance data in order to fully evaluate this approach to corrosion screening. Corrosion test screening of candidates for the oxygen reduction electrode of the alkaline fuel cell was applied to two substances, the pyrochlore Pb2Ru2O6.5 and the spinel NiCo2O4. The substrate gold screen and a sample of the IFC Orbiter Pt-Au performance electrode were included as blanks. The pyrochlore data indicate relative stability, although nothing yet can be said about long term stability. The spinel was plainly unstable. For this type of testing to be validated, comparisons will have to be made with long term performance tests.
Davis, Stacy N; Christy, Shannon M; Chavarria, Enmanuel A; Abdulla, Rania; Sutton, Steven K; Schmidt, Alyssa R; Vadaparampil, Susan T; Quinn, Gwendolyn P; Simmons, Vani N; Ufondu, Chukwudi B; Ravindra, Chitra; Schultz, Ida; Roetzheim, Richard G; Shibata, David; Meade, Cathy D; Gwede, Clement K
2017-04-15
The objective of the current study was to improve colorectal cancer (CRC) screening uptake with the fecal immunochemical test (FIT). The current study investigated the differential impact of a multicomponent, targeted, low-literacy educational intervention compared with a standard, nontargeted educational intervention. Patients aged 50 to 75 years who were of average CRC risk and not up-to-date with CRC screening were recruited from either a federally qualified health center or a primary care community health clinic. Patients were randomized to the intervention condition (targeted photonovella booklet/DVD plus FIT kit) or comparison condition (standard Centers for Disease Control and Prevention brochure plus FIT kit). The main outcome was screening with FIT within 180 days of delivery of the intervention. Of the 416 participants, 54% were female; the participants were racially and ethnically diverse (66% white, 10% Hispanic, and 28% African American), predominantly of low income, and insured (the majority had county health insurance). Overall, the FIT completion rate was 81%, with 78.1% of participants in the intervention versus 83.5% of those in the comparison condition completing FIT (P = .17). In multivariate analysis, having health insurance was found to be the primary factor predicting a lack of FIT screening (adjusted odds ratio, 2.10; 95% confidence interval, 1.04-4.26 [P = .04]). The multicomponent, targeted, low-literacy materials were not found to be significantly different or more effective in increasing FIT uptake compared with the nontargeted materials. Provision of a FIT test plus education may provide a key impetus to improve the completion of CRC screening. The type of educational material (targeted vs nontargeted) may matter less. The findings of the current study provide a unique opportunity for clinics to adopt FIT and to choose the type of patient education materials based on clinic, provider, and patient preferences. Cancer 2017;123:1390-1400. © 2016 American Cancer Society. © 2016 American Cancer Society.
The Yucatan miniature swine as an in vivo model for screening skin depigmentation.
Nair, X; Tramposch, K M
1991-12-01
The usefulness of the Yucatan miniature pig as a screen for skin dipigmenting activity by topical application was evaluated with standard compounds. This is a naturally occurring breed of swine with light brown to dark brown skin that is relatively hairless. The skin morphology, including the pattern of pigment distribution, in this breed of swine closely resembles the human skin. Test compounds examined in this study included the three standard compounds with known clinical depigmenting activity, hydroquinone (HQ), 4-hydroxyanisole (4HA) and tert-butyl catechol (TBC), each at a 5% concentration. Test materials in 25 microliters of propylene glycol/ethanol (50:50) were applied topically twice daily, 7 days a week for 90 days to test sites on each side of the dorsal mid-line. Test sites were graded weekly for variation in pigmentation and local irritation. After 90 days of test material application, skin biopsies of the test sites were taken for histological evaluation. Topical application of HQ, 4HA and TBC promoted marked skin depigmentation which was substantiated by reductions of pigment and melanocytes observed on microscopic examination. While both HQ and TBC produced marked local irritation, 4HA was only mildly irritating. These results suggest that the Yucatan pig, could be a potentially useful model for screening compounds with skin depigmenting activity.
Comparison of Refractory Performance in Black Liquor Gasifiers and a Smelt Test System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peascoe, RA
2001-09-25
Prior laboratory corrosion studies along with experience at the black liquor gasifier in New Bern, North Carolina, clearly demonstrate that serious material problems exist with the gasifier's refractory lining. Mullite-based and alumina-based refractories used at the New Bern facility suffered significant degradation even though they reportedly performed adequately in smaller scale systems. Oak Ridge National Laboratory's involvement in the failure analysis, and the initial exploration of suitable replacement materials, led to the realization that a simple and reliable, complementary method for refractory screening was needed. The development of a laboratory test system and its suitability for simulating the environment ofmore » black liquor gasifiers was undertaken. Identification and characterization of corrosion products were used to evaluate the test system as a rapid screening tool for refractory performance and as a predictor of refractory lifetime. Results from the test systems and pl ants were qualitatively similar.« less
Bernalte, E; Marín Sánchez, C; Pinilla Gil, E
2011-03-09
The applicability of commercial screen-printed gold electrodes (SPGEs) for the determination of Hg(II) in ambient water samples by square wave anodic stripping voltammetry has been demonstrated. Electrode conditioning procedures, chemical and instrumental variables have been optimized to develop a reliable method capable of measuring dissolved mercury in the low ng mL(-1) range (detection limit 1.1 ng mL(-1)), useful for pollution monitoring or screening purposes. The proposed method was tested with the NIST 1641d Mercury in Water Standard Reference Material (recoveries 90.0-110%) and the NCS ZC 76303 Mercury in Water Certified Reference Material (recoveries 82.5-90.6%). Waste water samples from industrial origin and fortified rain water samples were assayed for mercury by the proposed method and by a reference ICP-MS method, with good agreement. Screen printing technology thus opens a useful way for the construction of reliable electrochemical sensors for decentralized or even field Hg(II) testing. Copyright © 2011 Elsevier B.V. All rights reserved.
Apparatus for Screening Multiple Oxygen-Reduction Catalysts
NASA Technical Reports Server (NTRS)
Whitacre, Jay; Narayanan, Sekharipuram
2009-01-01
An apparatus that includes an array of multiple electrodes has been invented as a means of simultaneously testing multiple materials for their utility as oxygen-reduction catalysts in fuel cells. The apparatus ensures comparability of test results by exposing all the catalyst-material specimens to the same electrolytic test solution at the same potential. Heretofore, it has been possible to test only one specimen at a time, using a precise rotating disk electrode that provides a controlled flux of solution to the surface of the specimen.
NASA Technical Reports Server (NTRS)
Valentine, Peter G.; Lawrence, Timothy W.; Gubert, Michael K.; Milos, Frank S.; Kiser, James D.; Ohlhorst, Craig W.; Koenig, John R.
2006-01-01
As a collaborative effort among NASA Centers, the "Lightweight Nonmetallic Thermal Protection Materials Technology" Project was set up to assist mission/vehicle design trade studies, to support risk reduction in thermal protection system (TPS) material selections, to facilitate vehicle mass optimization, and to aid development of human-rated TPS qualification and certification plans. Missions performing aerocapture, aerobraking, or direct aeroentry rely on advanced heatshields that allow reductions in spacecraft mass by minimizing propellant requirements. Information will be presented on candidate materials for such reentry approaches and on screening tests conducted (material property and space environmental effects tests) to evaluate viable candidates. Seventeen materials, in three classes (ablatives, tiles, and ceramic matrix composites), were studied. In additional to physical, mechanical, and thermal property tests, high heat flux laser tests and simulated-reentry oxidation tests were performed. Space environmental effects testing, which included exposures to electrons, atomic oxygen, and hypervelocity impacts, was also conducted.
Testing and Selection of Fire-Resistant Materials for Spacecraft Use
NASA Technical Reports Server (NTRS)
Friedman, Robert; Jackson, Brian; Olson, Sandra
2000-01-01
Spacecraft fire-safety strategy emphasizes prevention, mostly through the selection of onboard items classified accord- ing to their fire resistance. The principal NASA acceptance tests described in this paper assess the flammability of materials and components under "worst-case" normal-gravity conditions of upward flame spread in controlled-oxygen atmospheres. Tests conducted on the ground, however, cannot duplicate the unique fire characteristics in the nonbuoyant low-gravity environment of orbiting spacecraft. Research shows that flammability an fire-spread rates in low gravity are sensitive to forced convection (ventilation flows) and atmospheric-oxygen concentration. These research results are helping to define new material-screening test methods that will better evaluate material performance in spacecraft.
Sheikh Rashid, Marya; Leensen, Monique C J; de Laat, Jan A P M; Dreschler, Wouter A
2017-11-01
The "Occupational Earcheck" (OEC) is a Dutch online self-screening speech-in-noise test developed for the detection of occupational high-frequency hearing loss (HFHL). This study evaluates an optimised version of the test and determines the most appropriate masking noise. The original OEC was improved by homogenisation of the speech material, and shortening the test. A laboratory-based cross-sectional study was performed in which the optimised OEC in five alternative masking noise conditions was evaluated. The study was conducted on 18 normal-hearing (NH) adults, and 15 middle-aged listeners with HFHL. The OEC in a low-pass (LP) filtered stationary background noise (test version LP 3: with a cut-off frequency of 1.6 kHz, and a noise floor of -12 dB) was the most accurate version tested. The test showed a reasonable sensitivity (93%), and specificity (94%) and test reliability (intra-class correlation coefficient: 0.84, mean within-subject standard deviation: 1.5 dB SNR, slope of psychometric function: 13.1%/dB SNR). The improved OEC, with homogenous word material in a LP filtered noise, appears to be suitable for the discrimination between younger NH listeners and older listeners with HFHL. The appropriateness of the OEC for screening purposes in an occupational setting will be studied further.
Corrosion testing of candidates for the alkaline fuel cell cathode
NASA Technical Reports Server (NTRS)
Singer, Joseph; Fielder, William L.
1990-01-01
Current/voltage data have been obtained for specially made corrosion electrodes of some oxides and of gold materials for the purpose of developing a screening test of catalysts and supports for use at the cathode of the alkaline fuel cell. The data consist of measurements of current at fixed potentials and cyclic voltammograms. These data will have to be correlated with longtime performance data in order to evaluate fully this approach to corrosion screening.
Code of Federal Regulations, 2010 CFR
2010-01-01
... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...
Code of Federal Regulations, 2013 CFR
2013-01-01
... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...
Code of Federal Regulations, 2014 CFR
2014-01-01
... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...
Code of Federal Regulations, 2012 CFR
2012-01-01
... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...
Code of Federal Regulations, 2011 CFR
2011-01-01
... means a group of validity screening tests that were made from the same starting material. ... past 24 hours. Adulterated specimen means a urine specimen that has been altered, as evidenced by test... whole specimen. Analytical run means the process of testing a group of urine specimens for validity or...
A comparison of relative toxicity rankings by some small-scale laboratory tests
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Cumming, H. J.
1977-01-01
Small-scale laboratory tests for fire toxicity, suitable for use in the average laboratory hood, are needed for screening and ranking materials on the basis of relative toxicity. The performance of wool, cotton, and aromatic polyamide under several test procedures is presented.
Combustion toxicology of epoxy/carbon fiber composites
NASA Technical Reports Server (NTRS)
Cagliostro, D. E.
1981-01-01
A combustion toxicology test was developed to screen materials for aerospace applications. The system is called the radiant panel test facility. A description of the facility and some preliminary results from tests on a Navy 3501-6AS composite, a typical composite for fighter aircraft, are presented.
United in Prevention–Electrocardiographic Screening for Chronic Obstructive Pulmonary Disease
Mazic, Sanja; Stajic, Zoran; Djelic, Marina; Zlatkovic-Svenda, Mirjana; Putnikovic, Biljana
2013-01-01
CONFLICT OF INTEREST: NONE DECLARED Introduction P-wave abnormalities on the resting electrocardiogram have been associated with cardiovascular or pulmonary disease. So far, “Gothic” P wave and verticalization of the frontal plane axis is related to lung disease, particularly obstructive lung disease. Aim We tested if inverted P wave in AVl as a lone criteria of P wave axis >70° could be screening tool for emphysema. Material and method 1095 routine electrocardiograms (ECGs) were reviewed which yielded 478 (82,1%) ECGs with vertical P-axis in sinus rhythm. Charts were reviewed for the diagnosis of COPD and emphysema based on medical history and pulmonary function tests. Conclusion Electrocardiogram is very effective screening tool not only in cardiovascular field but in chronic obstructive pulmonary disease. The verticality of the P axis is usually immediately apparent, making electrocardiogram rapid screening test for emphysema. PMID:24058253
Explosive Characteristics of Carbonaceous Nanoparticles
NASA Astrophysics Data System (ADS)
Turkevich, Leonid; Fernback, Joseph; Dastidar, Ashok
2013-03-01
Explosion testing has been performed on 20 codes of carbonaceous particles. These include SWCNTs (single-walled carbon nanotubes), MWCNTs (multi-walled carbon nanotubes), CNFs (carbon nanofibers), graphene, diamond, fullerene, carbon blacks and graphites. Explosion screening was performed in a 20 L explosion chamber (ASTM E1226-10 protocol), at a (dilute) concentration of 500 g/m3, using a 5 kJ ignition source. Time traces of overpressure were recorded. Samples exhibited overpressures of 5-7 bar, and deflagration index KSt = V1/3 (dp/pt)max ~ 10 - 80 bar-m/s, which places these materials in European Dust Explosion Class St-1 (similar to cotton and wood dust). There was minimal variation between these different materials. The explosive characteristics of these carbonaceous powders are uncorrelated with particle size (BET specific surface area). Additional tests were performed on selected materials to identify minimum explosive concentration [MEC]. These materials exhibit MEC ~ 101 -102 g/m3 (lower than the MEC for coals). The concentration scans confirm that the earlier screening was performed under fuel-rich conditions (i.e. the maximum over-pressure and deflagration index exceed the screening values); e.g. the true fullerene KSt ~ 200 bar-m/s, placing it borderline St-1/St-2. Work supported through the NIOSH Nanotechnology Research Center (NTRC)
Quaife, Samantha L; Ruparel, Mamta; Beeken, Rebecca J; McEwen, Andy; Isitt, John; Nolan, Gary; Sennett, Karen; Baldwin, David R; Duffy, Stephen W; Janes, Samuel M; Wardle, Jane
2016-04-20
Participation in low-dose CT (LDCT) lung cancer screening offered in the trial context has been poor, especially among smokers from socioeconomically deprived backgrounds; a group for whom the risk-benefit ratio is improved due to their high risk of lung cancer. Attracting high risk participants is essential to the success and equity of any future screening programme. This study will investigate whether the observed low and biased uptake of screening can be improved using a targeted invitation strategy. A randomised controlled trial design will be used to test whether targeted invitation materials are effective at improving engagement with an offer of lung cancer screening for high risk candidates. Two thousand patients aged 60-75 and recorded as a smoker within the last five years by their GP, will be identified from primary care records and individually randomised to receive either intervention invitation materials (which take a targeted, stepped and low burden approach to information provision prior to the appointment) or control invitation materials. The primary outcome is uptake of a nurse-led 'lung health check' hospital appointment, during which patients will be offered a spirometry test, an exhaled carbon monoxide (CO) reading, and an LDCT if eligible. Initial data on demographics (i.e. age, sex, ethnicity, deprivation score) and smoking status will be collected in primary care and analysed to explore differences between attenders and non-attenders with respect to invitation group. Those who attend the lung health check will have further data on smoking collected during their appointment (including pack-year history, nicotine dependence and confidence to quit). Secondary outcomes will include willingness to be screened, uptake of LDCT and measures of informed decision-making to ensure the latter is not compromised by either invitation strategy. If effective at improving informed uptake of screening and reducing bias in participation, this invitation strategy could be adopted by local screening pilots or a national programme. This study was registered with the ISRCTN (International Standard Registered Clinical/soCial sTudy Number: ISRCTN21774741) on the 23rd September 2015 and the NIH ClinicalTrials.gov database (NCT0255810) on the 22nd September 2015.
NASA Technical Reports Server (NTRS)
Supkis, D. E.
1975-01-01
Selected fire-retardant materials for possible application to commercial aircraft are described. The results of flammability screening tests and information on the physical and chemical properties of both original and newly installed materials after extended use are presented in tabular form, with emphasis on wear properties, strength, puncture and tear resistances, and cleanability.
A numerical simulation on the flow of watershed filtration reactors using lignocellulosic materials
N. Hur; B. Choi; J.S. Han; E.W. Shin; S. Min; R.M. Rowell
2003-01-01
Pinyon juniper, a small-diameter and underutilized (SDU) lignocellulosic material, was harvested in New Mexico, identified as Juniperus monosperma at the USDA Forest Products Laboratory, chipped, fiberized and chemically modified to remove pollutants from wastewater. This juniper species was selected as a raw material through screening test for removal of pollutants...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nyholm, N.; Kristensen, P.
1992-04-01
An international ring test involving 14 laboratories was organized on behalf of the Commission of the European Economic Communities (EEC) with the purpose of evaluating two proposed screening methods for assessment of biodegradability in seawater: (a) a shake flask die-away test based primarily on analysis of dissolved organic carbon and (b) a closed bottle test based on determination of dissolved oxygen. Both tests are performed with nutrient-enriched natural seawater as the test medium and with no inoculum added other than the natural seawater microflora. The test methods are seawater versions of the modified OECD screening test and the closed bottlemore » test, respectively, adopted by the Organization for Economic Cooperation and Development (OECD) and by the EEC as tests for ready biodegradability.' The following five chemicals were examined: sodium benzoate, aniline, diethylene glycol, pentaerythritol, and 4-nitrophenol. Sodium benzoate and aniline, which are known to be generally readily biodegradable consistently degraded in practically all tests, thus demonstrating the technical feasibility of the methods. Like in previous ring tests with freshwater screening methods variable results were obtained with the other three compounds, which is believed primarily to be due to site-specific differences between the microflora of the different seawater samples used and to some extent also to differences in the applied concentrations of test material. A positive result with the screening methods indicates that the test substance will most likely degrade relatively rapidly in seawater from the site of collection, while a negative test result does not preclude biodegradability under environmental conditions where the concentrations of chemicals are much lower than the concentrations applied for analytical reasons in screening tests.« less
Relative toxicity of pyrolysis products of some materials used in home furnishings
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Furst, A.
1976-01-01
Seventy samples of cushioning and upholstery materials used in home furnishings were evaluated for relative toxicity by means of the USF/NASA toxicity screening test. The materials were variably toxic under pyrolysis conditions, and this test appeared suitable for discriminating among them on the bases of time to incapacitation and time to death. The addition of fire retardants to these materials to comply with flammability regulations either had no significant effect on toxicity, or resulted in a reduction in relative toxicity. The modification of materials to comply with California upholstered furniture flammability regulations appears to have resulted in desirable limitations on toxicity. Fifty percent of the 70 materials tested caused incapacitation earlier than did the materials in compliance, and 30 percent caused death earlier.
Evaluation of ELISA screening test for detecting aflatoxin in biogenic dust samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Durant, J.T.
Aflatoxin is a carcinogenic chemical that is sometimes produced when agricultural commodities are infested by the fungi Aspergillus flavus and A. Parasiticus. Aflatoxin has been found to be present in air samples taken around persons handling materials likely to be contaminated. The purpose of this investigation was to demonstrate the feasibility of using an Enzyme Linked Immunosorbent Assay (ELISA) test kit that was developed to screen for aflatoxin in bulk agricultural commodities, to an air sample. Samples were taken from two environments likely to be contaminated with aflatoxin, a dairy farm feed mixing operation and a peanut bagging operation. Themore » dust collected from these environments was considered to be biogenic, in that it originated primarily from biological materials.« less
Zapka, Jane G; Geller, Berta M; Bulliard, Jean-Luc; Fracheboud, Jacques; Sancho-Garnier, Helene; Ballard-Barbash, Rachel
2006-10-01
To profile and compare the content and presentation of written communications related to informed decision-making about mammography. Materials from 16 screening programs organized at the national or regional level were analyzed according to five major information domains suggested by the international literature. A majority of countries provided information on the program (interval, cost and quality). There was considerable variability in comprehensiveness of elements in the domains, e.g., test characteristics (false positive/negative) and pros and cons of screening. The majority noted the likelihood of recall for further tests, few commented on the risks of additional tests or finding unimportant tumors. The audit also found variation in presentation (words and pictures). Presentation of comprehensive, but balanced information on screening benefits and risks is complex and daunting. Issues such as framing effects, coupled with debate about screening efficacy are challenging to the design of effective information tools. The objective of increasing screening prevalence at the population level must be balanced with objectively presenting complete and clear information. Additional research is needed on how information (and mode of presentation) impact screening decisions. Public health officials need to articulate their objectives and review written communication according to important decision-making domains.
Advanced Gas Turbine (AGT) powertrain system development for automotive applications
NASA Technical Reports Server (NTRS)
1982-01-01
Topics covered include the AGT 101 engine test; compressor design modification; cold air turbine testing; Mod 1 alloy turbine rotor fabrication; combustion aspects; regenerator development; and thermal screening tests for ceramic materials. The foil gas bearings, rotor dynamics, and AGT controls and accessories are also considered.
Screening for Saponins Using the Blood Hemolysis Test. An Undergraduate Laboratory Experiment.
ERIC Educational Resources Information Center
Sotheeswaran, Subramaniam
1988-01-01
Describes an experiment for undergraduate chemistry laboratories involving a chemical found in plants and some sea animals. Discusses collection and identification of material, a hemolysis test, preparation of blood-coated agar plates, and application of samples. (CW)
Hu, Shurong; Dou, Xiaowen; Zhang, Lei; Xie, Yanjun; Yang, Shihai; Yang, Meihua
2018-05-22
A rapid screening of the most toxic aflatoxin B 1 (AFB 1 ) in medicinal materials of radix and rhizome was performed by an immune chromatography method for the first time. The colloidal gold immunochromatographic strip was prepared after optimization of the conjugation of gold particles with monoclonal antibody, the test line and the control line. Under optimized conditions, the detection limit of the constructed test strip was as low as 0.1 ng mL -1 and the total analysis was conducted within 15 min by naked eyes. Four kinds of medicinal materials (Gastrodia elata, Poria cocos, Bletilla striata and Radix Angelicae Dahuricae) were investigated by the strip. Various complex matrixes pay a significant influence on the feasibility and effectiveness of the strip screening in medicinal materials. Aiming to the characteristics of selected medicinal materials, the screening was successfully proceeded with extraction by 70% methanol-water as well as three-fold dilution in Gastrodia elata and Radix Angelicae Dahuricae, 70% methanol-PBS as well as four-fold dilution in Poria cocos., and 60% methanol-water as well as four-fold dilution in Bletilla striata. Among the collected 40 samples, one was found to be positive of AFB 1 with level above 5 μg kg -1 . The result was in a good agreement with those obtained from LC-MS/MS determination (6.12 μg kg -1 ). The gold immunochromatographic strip was demonstrated as a rapid, cost-effective, reliable and on-site screening technique for mycotoxins in starch and polysaccharides-rich herbal medicines. Copyright © 2018 Elsevier Ltd. All rights reserved.
McGregor, Lesley M.; von Wagner, Christian; Atkin, Wendy; Kralj-Hans, Ines; Halloran, Stephen P.; Handley, Graham; Logan, Richard F.; Rainbow, Sandra; Smith, Steve; Snowball, Julia; Thomas, Mary C.; Smith, Samuel G.; Vart, Gemma; Howe, Rosemary; Counsell, Nicholas; Hackshaw, Allan; Morris, Stephen; Duffy, Stephen W.; Raine, Rosalind; Wardle, Jane
2016-01-01
Objective. To test the effectiveness of adding a narrative leaflet to the current information material delivered by the NHS English colorectal cancer (CRC) screening programme on reducing socioeconomic inequalities in uptake. Participants. 150,417 adults (59–74 years) routinely invited to complete the guaiac Faecal Occult Blood test (gFOBt) in March 2013. Design. A cluster randomised controlled trial (ISRCTN74121020) to compare uptake between two arms. The control arm received the standard NHS CRC screening information material (SI) and the intervention arm received the standard information plus a supplementary narrative leaflet, which had previously been shown to increase screening intentions (SI + N). Between group comparisons were made for uptake overall and across socioeconomic status (SES). Results. Uptake was 57.7% and did not differ significantly between the two trial arms (SI: 58.5%; SI + N: 56.7%; odds ratio = 0.93; 95% confidence interval: 0.81–1.06; p = 0.27). There was no interaction between group and SES quintile (p = 0.44). Conclusions. Adding a narrative leaflet to existing information materials does not reduce the SES gradient in uptake. Despite the benefits of using a pragmatic trial design, the need to add to, rather than replace, existing information may have limited the true value of an evidence-based intervention on behaviour. PMID:27069473
Kang, Stella K; Jiang, Miao; Duszak, Richard; Heller, Samantha L; Hughes, Danny R; Moy, Linda
2018-06-05
Purpose To retrospectively assess whether there is an association between screening mammography and the use of a variety of preventive services in women who are enrolled in Medicare. Materials and Methods U.S. Medicare claims from 2010 to 2014 Research Identifiable Files were reviewed to retrospectively identify a group of women who underwent screening mammography and a control group without screening mammography in 2012. The screened group was divided into positive versus negative results at screening, and the positive subgroup was divided into false-positive and true-positive findings. Multivariate logistic regression models and inverse probability of treatment weighting were used to examine the relationship between screening status and the probabilities of undergoing Papanicolaou test, bone mass measurement, or influenza vaccination in the following 2 years. Results The cohort consisted of 555 705 patients, of whom 185 625 (33.4%) underwent mammography. After adjusting for patient demographics, comorbidities, geographic covariates, and baseline preventive care, women who underwent index screening mammography (with either positive or negative results) were more likely than unscreened women to later undergo Papanicolaou test (odds ratio [OR], 1.49; 95% confidence interval: 1.40, 1.58), bone mass measurement (OR, 1.70; 95% confidence interval: 1.63, 1.78), and influenza vaccine (OR, 1.45; 95% confidence interval: 1.37, 1.53). In women who had not undergone these preventive measures in the 2 years before screening mammography, use of these three services after false-positive findings at screening was no different than after true-negative findings at screening. Conclusion In beneficiaries of U.S. Medicare, use of screening mammography was associated with higher likelihood of adherence to other preventive guidelines, without a negative association between false-positive results and cervical cancer screening. © RSNA, 2018 Online supplemental material is available for this article.
Assessment of newborn screening parent education materials.
Arnold, Connie L; Davis, Terry C; Frempong, Janet Ohene; Humiston, Sharon G; Bocchini, Anna; Kennen, Estela M; Lloyd-Puryear, Michele
2006-05-01
The purpose of this study was to measure the readability and user-friendliness (clarity, complexity, organization, appearance, and cultural appropriateness of materials) of parent education brochures on newborn screening. We studied English-language versions of the brochures that state newborn screening programs prepare and distribute. We obtained brochures from 48 states and Puerto Rico. We evaluated each brochure for readability with the Flesch reading ease formula. User-friendliness of the brochures was assessed with an instrument we created that contained 22 specific criteria grouped into 5 categories, ie, layout, illustrations, message, manageable information, and cultural appropriateness. Most current newborn screening brochures should be revised to make them more readable and user-friendly for parents. Ninety-two percent of brochures were written at a reading level that is higher than the average reading level of US adults (eighth-grade level). In most brochures, the essential information for parents was buried. Although all brochures were brief and focused on the newborn screening tests being performed, 81% needed improvement in getting to the point quickly and making it easy for parents to identify what they needed to know or to do. None of the brochures scored high in all 22 criteria on the user-friendliness checklist. Parent education materials about newborn screening should be revised to be easier to read and more user-friendly, by lowering the reading difficulty to eighth-grade level and focusing on issues such as layout, illustrations, message, information, and cultural appropriateness. It is important that state newborn screening programs and organizations work with parents to develop and to evaluate materials to ensure that they are user-friendly.
Development of An Advanced JP-8 Fuel
1993-12-01
included the Microthermal Precipitation Test (MTP), Fuel Reactor Test, Hot Liquid Process Simulator (HLPS), and Isothermal Corrosion Oxidation Test (ICOT... Microthermal Precipitation Test The impetus for this development effort was the need for a screening test that could discriminate between fuels of...varying propensity to produce thermally induced insoluble particulate material in the bulk fuel. The Microthermal Precipitation (MTP) test thermally
Stults, Cheryl L M; Ansell, Jennifer M; Shaw, Arthur J; Nagao, Lee M
2015-02-01
Polymeric materials are often used in pharmaceutical packaging, delivery systems, and manufacturing components. There is continued concern that chemical entities from polymeric components may leach into various dosage forms, particularly those that are comprised of liquids such as parenterals, injectables, ophthalmics, and inhalation products. In some cases, polymeric components are subjected to routine extractables testing as a control measure. To reduce the risk of discovering leachables during stability studies late in the development process, or components that may fail extractables release criteria, it is proposed that extractables testing on polymer resins may be useful as a screening tool. Two studies have been performed to evaluate whether the extractables profile generated from a polymer resin is representative of the extractables profile of components made from that same resin. The ELSIE Consortium pilot program examined polyvinyl chloride and polyethylene, and another study evaluated polypropylene and a copolymer of polycarbonate and acrylonitrile butadiene styrene. The test materials were comprised of polymer resin and processed resin or molded components. Volatile, semi-volatile, and nonvolatile chemical profiles were evaluated after headspace sampling and extraction with solvents of varying polarity and pH. The findings from these studies indicate that there may or may not be differences between extractables profiles obtained from resins and processed forms of the resin depending on the type of material, the compounds of interest, and extraction conditions used. Extractables testing of polymer resins is useful for material screening and in certain situations may replace routine component testing.
2013-01-01
Background Appropriate patient information materials may support the consumer’s decision to attend or not to attend colorectal cancer (CRC) screening tests (fecal occult blood test and screening colonoscopy). The aim of this study was to develop a list of criteria to assess whether written health information materials on CRC screening provide balanced, unbiased, quantified, understandable, and evidence-based health information (EBHI) about CRC and CRC screening. Methods The list of criteria was developed based on recommendations and assessment tools for health information in the following steps: (1) Systematic literature search in 13 electronic databases (search period: 2000–2010) and completed by an Internet search (2) Extraction of identified criteria (3) Grouping of criteria into categories and domains (4) Compilation of a manual of adequate answers derived from systematic reviews and S3 guidelines (5) Review by external experts (6) Modification (7) Final discussion with external experts. Results Thirty-one publications on health information tools and recommendations were identified. The final list of criteria includes a total of 230 single criteria in three generic domains (formal issues, presentation and understandability, and neutrality and balance) and one CRC-specific domain. A multi-dimensional rating approach was used whenever appropriate (e.g., rating for the presence, correctness, presentation and level of evidence of information). Free text input was allowed to ensure the transparency of assessment. The answer manual proved to be essential to the rating process. Quantitative analyses can be made depending on the level and dimensions of criteria. Conclusions This comprehensive list of criteria clearly has a wider range of evaluation than previous assessment tools. It is not intended as a final quality assessment tool, but as a first step toward thorough evaluation of specific information materials for their adherence to EBHI requirements. This criteria list may also be used to revise leaflets and to develop evidence-based health information on CRC screening. After adjustment for different procedure-specific criteria, the list of criteria can also be applied to other cancer screening procedures. PMID:24028691
NASA Technical Reports Server (NTRS)
Turner, J. E.
1993-01-01
An elastomeric O-ring material is used in the joints of the redesigned solid motors (RSRM's) of the National Space Transportation System (NSTS). The selection of the O-ring material used in the RSRM's was a very thorough process that included efforts by NASA's Marshall Space Flight Center and the Langley Research Center, and the Thiokol Corporation. One of the efforts performed at MSFC was an extensive in-house laboratory test regime to screen potential O-ring materials and ultimately to characterize the elastomeric material that was chosen to be used in the RSRM's. The laboratory tests performed at MSFC are summarized.
Neish, Emma M.; Miller, Nancy S.; Dhere, Tanvi; Burd, Eileen M.; Carpentieri, Cynthia; Sitchenko, Kaitlin L.
2017-01-01
ABSTRACT Fecal microbiota transplantation is an efficacious and inexpensive therapy for recurrent Clostridium difficile infection, yet its safety is thought to depend on appropriate fecal donor screening. FDA guidance for regulation of this procedure is in flux, but screening and manufacture of fecal material from asymptomatic donors present many challenges to clinical laboratories. This minireview summarizes FDA regulatory changes, principles of donor selection, and recommended laboratory screening practices for fecal microbiota transplantation. PMID:28077694
CRT Monitors: Do They Interfere with Learning?
ERIC Educational Resources Information Center
Garland, Kate J.; Noyes, Jan M.
2004-01-01
Research suggests screen reading is slower and possibly less accurate than reading from paper. Six study and test sessions over 10 months examined correct scores and retrieval responses for learning material presented via these two media. Correct scores did not differ suggesting that close matching of material can eliminate any decrement in…
NASA Technical Reports Server (NTRS)
Clancy, H. M.
1972-01-01
Vacuum stability screening tests were performed on the Apollo 15 Scientific Instrument Module (SIM) bay nonmetallic materials in accordance with the NASA document SP-R-0022. The testing was necessary to support the evaluation to determine the effect material outgassing contamination would have on the SIM bay optical lenses and sensing devices. The Apollo 15 SIM experiments were highly successful, therefore, it is assumed that contamination due to the outgassing of nonmetallic materials did not affect equipment operation. A related problem, the reversion of a silicone rubber grommet which affected an electrical motor switch operation is also reported.
Pilot trial on separation conditions for diaper recycling.
Kim, Kyung-Shin; Cho, Hee-Sun
2017-09-01
By utilizing laboratory-scale tests, the optimal separation conditions for diaper recycling were identified, and then, these conditions were validated by a pilot trial. In this research, we determined the mass balances derived during various processing steps and identified the most feasible procedures to use for separating each material in the output flow. The results showed that drum screening was not able to remove all the fiber and super absorbent particles (SAP) in the plastic-rich fraction and that cellulose enzyme treatment can be a good solution. To achieve better separation of fibers and SAP, slot screening followed by a cleaner is a potential option. A feasible diaper recycling process was recommended based on these results. This process involves screening and enzymatic treatment for the plastic fraction, and screening, cleaning, and thickening for the fiber fraction. Treatment procedures were also proposed for the SAP fraction and rejected materials. Copyright © 2017. Published by Elsevier Ltd.
Remediation of AMD using natural and waste material
DOE Office of Scientific and Technical Information (OSTI.GOV)
Basir, Nur Athirah Mohamad; Yaacob, Wan Zuhairi Wan
2014-09-03
Acid Mine Drainage (AMD) is highly acidic, sulphate rich and frequently carries a high transition metal and heavy metal burden. These AMD's eventually migrate into streams and rivers and impact negatively on the quality of these water bodies. So it is dire necessary to treat this AMD. Various materials such as ladle furnace slag (LFS), bentonite, zeolite, active carbon and kaolinite are currently available to remove heavy metals from contaminated water. All these materials are capable to rise up the pH value and adsorb heavy metals. The process is divided into two stages; screening test and tank experiment. Screening testmore » is conduct by using Batch Equilibrium Test (BET), X-Ray Fluorescene (XRF) identification also Scanning Electron Microscopic (SEM) characteristic. The results showed that all the concentration of heavy metal are decreasing extremely and pH value rise up except for kaolinite. From screening test only ladle furnace slag, bentonite, zeolite and active carbon are chosen for the tank experiment. Tank experiment design with 18cm (H) X 15cm (L) X 15cm (H) was made by silica glass. All these treatment materials were stirred in the tank for 30 days. Initial pH for all tanks is 2.4 and after 30 days is changing into 6.11, 3.91, 2.98 and 2.71 for LFS, bentonite, active carbon as well as zeolite respectively. LFS is the best material for absorption of Zn, Mn and Cu in the synthetic solution. Meanwhile, bentonite is the best absorbent for Ni, Fe and Cd. The conclusion shows that LFS might have big potentials to control AMD pollution base on neutralize pH resulting in a great improvement in the quality of the water.« less
ERIC Educational Resources Information Center
Manela, Roger; And Others
One of six information booklets with accompanying training materials for the Medicaid Early and Periodic Screening Diagnosis and Treatment (EPSDT) program, this booklet describes the stages of child growth and development and some of the health problems which EPSDT clients might have. Section I describes tests commonly included in an EPSDT…
NASA Technical Reports Server (NTRS)
Sepka, Steven; Gasch, Matthew; Beck, Robin A.; White, Susan
2012-01-01
The material testing results described in this paper were part of a material development program of vendor-supplied, proposed heat shield materials. The goal of this program was to develop low density, rigid material systems with an appreciable weight savings over phenolic-impregnated carbon ablator (PICA) while improving material response performance. New technologies, such as PICA-like materials in honeycomb or materials with variable density through-the-thickness were tested. The material testing took place at the Wright-Patterson Air Force Base Laser Hardened Materials Laboratory (LHMEL) using a 10.6 micron CO2 laser operating with the test articles immersed in a nitrogen-gas environment at 1 atmosphere pressure. Test measurements included thermocouple readings of in-depth temperatures, pyrometer readings of surface temperatures, weight scale readings of mass loss, and sectioned-sample readings of char depth. Two laser exposures were applied. The first exposure was at an irradiance of 450 W/cm2 for 50 or 60 seconds to simulate an aerocapture maneuver. The second laser exposure was at an irradiance of 115 W/cm2 for 100 seconds to simulate a planetary entry. Results from Rounds 1 and 2 of these screening tests are summarized.
NASA Technical Reports Server (NTRS)
Oslon, Sandra. L.; Ferkul, Paul
2012-01-01
Drop tower tests are conducted at Martian gravity to determine the flammability of three materials compared to previous tests in other normal gravity and reduced gravity environments. The comparison is made with consideration of a modified NASA standard test protocol. Material flammability limits in the different gravity and flow environments are tabulated to determine the factor of safety associated with normal gravity flammability screening. Previous testing at microgravity and Lunar gravity indicated that some materials burned to lower oxygen concentrations in low gravity than in normal gravity, although the low g extinction limit criteria are not the same as 1g due to time constraints in drop testing. Similarly, the data presented in this paper for Martian gravity suggest that there is a gravity level below Earth s at which materials burn more readily than on Earth. If proven for more materials, this may indicate the need to include a factor of safety on 1g flammability limits.
The sensitivity of relative toxicity rankings by the USF/NASA test method to some test variables
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Labossiere, L. A.; Leon, H. A.; Kourtides, D. A.; Parker, J. A.; Hsu, M.-T. S.
1976-01-01
Pyrolysis temperature and the distance between the source and sensor of effluents are two important variables in tests for relative toxicity. Modifications of the USF/NASA toxicity screening test method to increase the upper temperature limit of pyrolysis, reduce the distance between the sample and the test animals, and increase the chamber volume available for animal occupancy, did not significantly alter rankings of relative toxicity of four representative materials. The changes rendered some differences no longer significant, but did not reverse any rankings. The materials studied were cotton, wool, aromatic polyamide, and polybenzimidazole.
New Screening Test Developed for the Blanching Resistance of Copper Alloys
NASA Technical Reports Server (NTRS)
Thomas-Ogbuji, Linus U.
2004-01-01
NASA's extensive efforts towards more efficient, safer, and more affordable space transportation include the development of new thrust-cell liner materials with improved capabilities and longer lives. For rocket engines fueled with liquid hydrogen, an important metric of liner performance is resistance to blanching, a phenomenon of localized wastage by cycles of oxidation-reduction due to local imbalance in the oxygen-fuel ratio. The current liner of the Space Shuttle Main Engine combustion chamber, a Cu-3Ag-0.5Zr alloy (NARloy-Z) is degraded in service by blanching. Heretofore, evaluating a liner material for blanching resistance involved elaborate and expensive hot-fire tests performed on rocket test stands. To simplify that evaluation, researchers at the NASA Glenn Research Center developed a screening test that uses simple, in situ oxidation-reduction cycling in a thermogravimetric analyzer (TGA). The principle behind this test is that resistance to oxidation or to the reduction of oxide, or both, implies resistance to blanching. Using this test as a preliminary tool to screen alloys for blanching resistance can improve reliability and save time and money. In this test a small polished coupon is hung in a TGA furnace at the desired (service) temperature. Oxidizing and reducing gases are introduced cyclically, in programmed amounts. Cycle durations are chosen by calibration, such that all copper oxides formed by oxidation are fully reduced in the next reduction interval. The sample weight is continuously acquired by the TGA as usual.
Microelectronic components and metallic oxide studies and applications
NASA Technical Reports Server (NTRS)
Williams, L., Jr.
1976-01-01
The project involved work in two basic areas: (1) Evaluation of commercial screen printable thick film conductors, resistors, thermistors and dielectrics as well as alumina substrates used in hybird microelectronics industries. Results of tests made on materials produced by seven companies are presented. (2) Experimental studies on metallic oxides of copper and vanadium, in an effort to determine their electrochemical properties in crystalline, powder mixtures and as screen printable thick films constituted the second phase of the research effort. Oxide investigations were aimed at finding possible applications of these materials as switching devices memory elements and sensors.
CORROSION STUDIES FOR A FUSED SALT-LIQUID METAL EXTRACTION PROCESS FOR THE LIQUID METAL FUEL REACTOR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Susskind, H.; Hill, F.B.; Green, L.
1960-06-30
Corrosion screening tests were carried out on potential materials of construction for use in a fused salt-liquid metal extraction process plant. The corrodents of interest were NaCl--KCl-- MgCl/sub 2/ eutectic, LiCl--KCl eutectic, Bi-- U fuel, and BiCl/sub 3/, either separately or in various combinations. Screening tests to determine the resistance of a wide range of commercial alloys to the corrodents were performed in static and tilting-furnace capsules. Some ceramic materials were tested in static capsules. Largerscale tests of metallic materials were conducted in thermal convection loops and in a forced circulation loop. Some of the tests were conducted isothermally atmore » 500 deg C, and others were performed under 40 to 50 deg C temperature differences at roughly the same teinperature level. On the basis of metallographic examination of exposed test tabs and chemical analyses of corrodents, it was found that the binary and ternary eutectics by themselves produced little attack on any of the materials tested. A wide variety of materials including 1020 mild steel, 2 1/4 Cr--1 Mo alloy steel, types 304 (ELC), 310, 316, 347, 430, and 446 stainless steel, 16-1 Croloy, Inconel, Hastelloy C, Inor-8, Mo, and Ta is, therefore, available for further study. Corrosion by the ternary salt-fuel system was characteristic of that produced by the fuel alone. Alloys such as 1020 mild steel, and 1 1/4 Cr--1/ 2 Mo, and 2 1/4 Cr--1 Mo alloy steel, which are resistant to fuel, would be likely choices at present for container materials. BiCl/sub 3/ produced extensive attack on ternary salt-fuel containers when the fuel contained insufficient concentrations of oxidizable solutes. Au and Al/sub 2/O/sub 3/ were the only materials not attacked by BiCl/sub 3/ in ternary salt alone. (auth)« less
Active-learning strategies in computer-assisted drug discovery.
Reker, Daniel; Schneider, Gisbert
2015-04-01
High-throughput compound screening is time and resource consuming, and considerable effort is invested into screening compound libraries, profiling, and selecting the most promising candidates for further testing. Active-learning methods assist the selection process by focusing on areas of chemical space that have the greatest chance of success while considering structural novelty. The core feature of these algorithms is their ability to adapt the structure-activity landscapes through feedback. Instead of full-deck screening, only focused subsets of compounds are tested, and the experimental readout is used to refine molecule selection for subsequent screening cycles. Once implemented, these techniques have the potential to reduce costs and save precious materials. Here, we provide a comprehensive overview of the various computational active-learning approaches and outline their potential for drug discovery. Copyright © 2014 Elsevier Ltd. All rights reserved.
Ceramic regenerator systems development program. [for automobile gas turbine engines
NASA Technical Reports Server (NTRS)
Cook, J. A.; Fucinari, C. A.; Lingscheit, J. N.; Rahnke, C. J.
1977-01-01
Ceramic regenerator cores are considered that can be used in passenger car gas turbine engines, Stirling engines, and industrial/truck gas turbine engines. Improved materials and design concepts aimed at reducing or eliminating chemical attack were placed on durability test in Ford 707 industrial gas turbine engines. The results of 19,600 hours of turbine engine durability testing are described. Two materials, aluminum silicate and magnesium aluminum silicate, continue to show promise toward achieving the durability objectives of this program. A regenerator core made from aluminum silicate showed minimal evidence of chemical attack damage after 6935 hours of engine test at 800 C and another showed little distress after 3510 hours at 982 C. Results obtained in ceramic material screening tests, aerothermodynamic performance tests, stress analysis, cost studies, and material specifications are also included.
Ricketts, Ellie J; Francischetto, Elaine O'Connell; Wallace, Louise M; Hogan, Angela; McNulty, Cliodna A M
2016-03-22
Chlamydia trachomatis remains a significant public health problem. We used a complex intervention, with general practice staff, consisting of practice based workshops, posters, computer prompts and testing feedback and feedback to increase routine chlamydia screening tests in under 25 year olds in South West England. We aimed to evaluate how intervention components were received by staff and to understand what determined their implementation into ongoing practice. We used face-to-face and telephone individual interviews with 29 general practice staff analysed thematically within a Normalisation Process Theory Framework which explores: 1. Coherence (if participants understand the purpose of the intervention); 2. Cognitive participation (engagement with and implementation of the intervention); 3. Collective action (work actually undertaken that drives the intervention forwards); 4. Reflexive monitoring (assessment of the impact of the intervention). Our results showed coherence as all staff including receptionists understood the purpose of the training was to make them aware of the value of chlamydia screening tests and how to increase this in their general practice. The training was described by nearly all staff as being of high quality and responsible for creating a shared understanding between staff of how to undertake routine chlamydia screening. Cognitive participation in many general practice staff teams was demonstrated through their engagement by meeting after the training to discuss implementation, which confirmed the role of each staff member and the use of materials. However several participants still felt unable to discuss chlamydia in many consultations or described sexual health as low priority among colleagues. National targets were considered so high for some general practice staff that they didn't engage with the screening intervention. Collective action work undertaken to drive the intervention included use of computer prompts which helped staff remember to make the offer, testing rate feedback and having a designated lead. Ensuring patients collected samples when still in the general practice was not attained in most general practices. Reflexive monitoring showed positive feedback from patients and other staff about the value of screening, and feedback about the general practices testing rates helped sustain activity. A complex intervention including interactive workshops, materials to help implementation and feedback can help chlamydia screening testing increase in general practices.
Simplified through-transmission test method for determination of a material's acoustic properties
USDA-ARS?s Scientific Manuscript database
Accepted acoustic testing standards are available; however, they require specialized hardware and software that are typically out of reach economically to the occasional practitioner. What is needed is a simple and inexpensive screening method that can provide a quick comparison for rapid identifica...
Wormhole Formation in RSRM Nozzle Joint Backfill
NASA Technical Reports Server (NTRS)
Stevens, J.
2000-01-01
The RSRM nozzle uses a barrier of RTV rubber upstream of the nozzle O-ring seals. Post flight inspection of the RSRM nozzle continues to reveal occurrence of "wormholes" into the RTV backfill. The term "wormholes", sometimes called "gas paths", indicates a gas flow path not caused by pre-existing voids, but by a little-understood internal failure mode of the material during motor operation. Fundamental understanding of the mechanics of the RSRM nozzle joints during motor operation, nonlinear viscoelastic characterization of the RTV backfill material, identification of the conditions that predispose the RTV to form wormholes, and screening of candidate replacement materials is being pursued by a joint effort between Thiokol Propulsion, NASA, and the Army Propulsion & Structures Directorate at Redstone Arsenal. The performance of the RTV backfill in the joint is controlled by the joint environment. Joint movement, which applies a tension and shear load on the material, coupled with the introduction of high pressure gas in combination create an environment that exceeds the capability of the material to withstand the wormhole effect. Little data exists to evaluate why the material fails under the modeled joint conditions, so an effort to characterize and evaluate the material under these conditions was undertaken. Viscoelastic property data from characterization testing will anchor structural analysis models. Data over a range of temperatures, environmental pressures, and strain rates was used to develop a nonlinear viscoelastic model to predict material performance, develop criteria for replacement materials, and quantify material properties influencing wormhole growth. Three joint simulation analogs were developed to analyze and validate joint thermal barrier (backfill) material performance. Two exploratory tests focus on detection of wormhole failure under specific motor operating conditions. A "validation" test system provides data to "validate" computer models and predictions. Finally, two candidate replacement materials are being screened and "validated" using the developed test systems.
Parts, Materials, and Processes Control Program for Expendable Launch Vehicles
2015-07-31
burn-in, electrical tests (DWV, room and hot IR, partial discharge when in corona region); perform DPA with SEM/EDX analysis of dielectric...life test; x-ray and vicinal illumination inspection; electrical tests (DWV, room and hot IR, partial discharge when in corona region) Termination...defects; proper voltage derating. Partial discharge testing, corona inception testing up to 60% of rated voltage; CSAM screening; voltage burn
Standard wool fabric as a reference material. [for fire toxicity tests
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Cumming, H. J.
1977-01-01
Standard wool fabric is investigated as a potential reference material. A screening test method for relative toxicity exposes four albino male rats enclosed in a 4.2 liter hemispherical chamber to pyrolysis effluents produced by pyrolyzing a 1.00 g sample under a variety of test conditions (200-800 C with a 40 C/min heating rate). It is found that for fabrics containing 86-100% wool, animal response remains virtually unchanged, although a 100% wool fabric is preferred as it eliminates local composition differences as a source of variation.
Ceramic regenerator systems development program
NASA Technical Reports Server (NTRS)
Fucinari, C. A.; Rahnke, C. J.; Rao, V. D. N.; Vallance, J. K.
1980-01-01
The DOE/NASA Ceramic Regenerator Design and Reliability Program aims to develop ceramic regenerator cores that can be used in passenger car and industrial/truck gas turbine engines. The major cause of failure of early gas turbine regenerators was found to be chemical attack of the ceramic material. Improved materials and design concepts aimed at reducing or eliminating chemical attack were placed on durability test in Ford 707 industrial gas turbine engines late in 1974. Results of 53,065 hours of turbine engine durability testing are described. Two materials, aluminum silicate and magnesium aluminum silicate, show promise. Five aluminum silicate cores attained the durability objective of 10,000 hours at 800 C (1472 F). Another aluminum silicate core shows minimal evidence of chemical attack after 8071 hours at 982 C (1800 F). Results obtained in ceramic material screening tests, aerothermodynamic performance tests, stress analysis, cost studies, and material specifications are included.
1982-01-01
bromide is listed as a positive interference. Nitric oxide and nitrogen dioxide can be detected by using the Draeger nitrous fumes detector tube. A... fumes exhibit a delay from the time of exposure to the onset of symptoms. This time delay would not be conducive for a rapid field screening test. It...Dangerous when strongly heated, emits highly toxic fumes . THRESHOLD LIMIT VALUE: No information available PHYSIOLOGICAL EFFECTS: A. Intensely irritating to
Environmental and Psychosocial Barriers to and Benefits of Cervical Cancer Screening in Kenya
Ragan, Kathleen; Lee Smith, Judith; Saraiya, Mona; Aketch, Millicent
2017-01-01
Abstract Background. Cervical cancer is the second most commonly diagnosed cancer in females and is a leading cause of cancer‐related mortality in Kenya; limited cervical cancer screening services may be a factor. Few studies have examined men's and women's perceptions on environmental and psychosocial barriers and benefits related to screening. Materials and Methods. In 2014, 60 women aged 25–49 years and 40 male partners participated in 10 focus groups (6 female and 4 male), in both rural and urban settings (Nairobi and Nyanza, Kenya), to explore perceptions about barriers to and benefits of cervical cancer screening. Focus groups were segmented by sex, language, geographic location, and screening status. Data were transcribed, translated into English, and analyzed by using qualitative software. Results. Participants identified screening as beneficial for initiating provider discussions about cancer but did not report it as a beneficial method for detecting precancers. Perceived screening barriers included access (transportation, cost), spousal approval, stigma, embarrassment during screening, concerns about speculum use causing infertility, fear of residual effects of test results, lack of knowledge, and religious or cultural beliefs. All participants reported concerns with having a male doctor perform screening tests; however, men uniquely reported the young age of a doctor as a barrier. Conclusion. Identifying perceived barriers and benefits among people in low‐ and middle‐income countries is important to successfully implementing emerging screening programs. The novel findings on barriers and benefits from this study can inform the development of targeted community outreach activities, communication strategies, and educational messages for patients, families, and providers. Implications for Practice. This article provides important information for stakeholders in clinical practice and research when assessing knowledge, beliefs, and acceptability of cervical cancer screening and treatment services in low‐ and middle‐resourced countries. Formative research findings provide information that could be used in the development of health interventions, community education messages, and materials. Additionally, this study illuminates the importance of understanding psychosocial barriers and facilitators to cervical cancer screening, community education, and reduction of stigma as important methods of improving prevention programs and increasing rates of screening among women. PMID:28167567
Geiger, Simon; Kasian, Olga; Mingers, Andrea M; Nicley, Shannon S; Haenen, Ken; Mayrhofer, Karl J J; Cherevko, Serhiy
2017-09-18
In searching for alternative oxygen evolution reaction (OER) catalysts for acidic water splitting, fast screening of the material intrinsic activity and stability in half-cell tests is of vital importance. The screening process significantly accelerates the discovery of new promising materials without the need of time-consuming real-cell analysis. In commonly employed tests, a conclusion on the catalyst stability is drawn solely on the basis of electrochemical data, for example, by evaluating potential-versus-time profiles. Herein important limitations of such approaches, which are related to the degradation of the backing electrode material, are demonstrated. State-of-the-art Ir-black powder is investigated for OER activity and for dissolution as a function of the backing electrode material. Even at very short time intervals materials like glassy carbon passivate, increasing the contact resistance and concealing the degradation phenomena of the electrocatalyst itself. Alternative backing electrodes like gold and boron-doped diamond show better stability and are thus recommended for short accelerated aging investigations. Moreover, parallel quantification of dissolution products in the electrolyte is shown to be of great importance for comparing OER catalyst feasibility. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Puckett, Mary C; Townsend, Julie S; Gelb, Cynthia A; Hager, Polly; Conlon, Amy; Stewart, Sherri L
2017-06-24
Because no effective methods for preventing or screening for ovarian cancer exist, symptom recognition is integral to its early detection. The Centers for Disease Control and Prevention's Inside Knowledge: Get the Facts about Gynecologic Cancer campaign was developed to raise awareness and educate women and providers about risk factors, symptoms, recommended screening, and prevention strategies for the five main gynecologic cancers, including ovarian cancer. Inside Knowledge campaign materials were utilized by CDC's National Comprehensive Cancer Control Program grantees to educate women and providers about gynecologic cancer from 2014 to 2015. Grantees recruited participants and held educational sessions using Inside Knowledge materials. Questionnaires were given before and after the sessions to assess changes in awareness, confidence, and behavioral intentions around gynecologic cancer information and analyzed in 2016. This analysis focused on an assessment of changes related to ovarian cancer information. Participants' knowledge increased after educational sessions. Among women, there were increases in correctly identifying that the Papanicolaou (Pap) test does not screen for ovarian cancer (89.2%) and that genetic testing is available (77.9%). There was a lower increase in knowledge that HPV is not a cause of ovarian cancer (56.4%). Providers and women reported significant increases in their confidence in their ability to talk to each other about gynecologic cancer post-session. Ovarian cancer awareness, confidence, and related behaviors increased in participants exposed to Inside Knowledge materials. Using these materials to increase knowledge could lead to more empowered patients, better provider-patient communications, and improved care for gynecologic cancers, including ovarian cancer.
Jenke, Dennis; Couch, Thomas R; Robinson, Sarah J; Volz, Trent J; Colton, Raymond H
2014-01-01
Extracts of plastic packaging, manufacturing, and delivery systems (or their materials of construction) are analyzed by chromatographic methods to establish the system's extractables profile. The testing strategy consists of multiple orthogonal chromatographic methods, for example, gas and liquid chromatography with multiple detection strategies. Although this orthogonal testing strategy is comprehensive, it is not necessarily complete and members of the extractables profile can elude detection and/or accurate identification/quantification. Because the chromatographic methods rarely indicate that some extractables have been missed, another means of assessing the completeness of the profiling activity must be established. If the extracts are aqueous and contain no organic additives (e.g., pH buffers), then they can be analyzed for their total organic carbon content (TOC). Additionally, the TOC of an extract can be calculated based on the extractables revealed by the screening analyses. The measured and calculated TOC can be reconciled to establish the completeness and accuracy of the extractables profile. If the reconciliation is poor, then the profile is either incomplete or inaccurate and additional testing is needed to establish the complete and accurate profile. Ten test materials and components of systems were extracted and their extracts characterized for organic extractables using typical screening procedures. Measured and calculated TOC was reconciled to establish the completeness of the revealed extractables profile. When the TOC reconciliation was incomplete, the profiling was augmented with additional analytical testing to reveal the missing members of the organic extractables profile. This process is illustrated via two case studies involving aqueous extracts of sterile filters. Plastic materials and systems used to manufacture, contain, store, and deliver pharmaceutical products are extracted and the extracts analyzed to establish the materials' (or systems') organic extractables profile. Such testing typically consists of multiple chromatographic approaches whose differences help to ensure that all organic extractables are revealed, measured, and identified. Nevertheless, this rigorous screening process is not infallible and certain organic extractables may elude detection. If the extraction medium is aqueous, the process of total organic carbon (TOC) reconciliation is proposed as a means of establishing when some organic extractables elude detection. In the reconciliation, the TOC of the extracts is both directly measured and calculated from the chromatographic data. The measured and calculated TOC is compared (or reconciled), and the degree of reconciliation is an indication of the completeness and accuracy of the organic extractables profiling. If the reconciliation is poor, then the extractables profile is either incomplete or inaccurate and additional testing must be performed to establish the complete and accurate profile. This article demonstrates the TOC reconciliation process by considering aqueous extracts of 10 different test articles. Incomplete reconciliations were augmented with additional testing to produce a more complete TOC reconciliation. © PDA, Inc. 2014.
Microprocessor-Controlled Laser Balancing System
NASA Technical Reports Server (NTRS)
Demuth, R. S.
1985-01-01
Material removed by laser action as part tested for balance. Directed by microprocessor, laser fires appropriate amount of pulses in correct locations to remove necessary amount of material. Operator and microprocessor software interact through video screen and keypad; no programing skills or unprompted system-control decisions required. System provides complete and accurate balancing in single load-and-spinup cycle.
NASA Technical Reports Server (NTRS)
Waterman, A. W.; Huxford, R. L.; Nelson, W. G.
1976-01-01
Molded high temperature plastic first and second stage rod seal elements were evaluated in seal assemblies to determine performance characteristics. These characteristics were compared with the performance of machined seal elements. The 6.35 cm second stage Chevron seal assembly was tested using molded Chevrons fabricated from five molding materials. Impulse screening tests conducted over a range of 311 K to 478 K revealed thermal setting deficiencies in the aromatic polyimide molding materials. Seal elements fabricated from aromatic copolyester materials structurally failed during impulse cycle calibration. Endurance testing of 3.85 million cycles at 450 K using MIL-H-83283 fluid showed poorer seal performance with the unfilled aromatic polyimide material than had been attained with seals machined from Vespel SP-21 material. The 6.35 cm first stage step-cut compression loaded seal ring fabricated from copolyester injection molding material failed structurally during impulse cycle calibration. Molding of complex shape rod seals was shown to be a potentially controllable technique, but additional molding material property testing is recommended.
Interventions to Improve Sexually Transmitted Disease Screening in Clinic-Based Settings.
Taylor, Melanie M; Frasure-Williams, Jessica; Burnett, Phyllis; Park, Ina U
2016-02-01
The asymptomatic nature and suboptimal screening rates of sexually transmitted diseases (STD) call for implementation of successful interventions to improve screening in community-based clinic settings with attention to cost and resources. We used MEDLINE to systematically review comparative analyses of interventions to improve STD (chlamydia, gonorrhea, or syphilis) screening or rescreening in clinic-based settings that were published between January 2000 and January 2014. Absolute differences in the percent of the target population screened between comparison groups or relative percent increase in the number of tests or patients tested were used to score the interventions as highly effective (>20% increase) or moderately effective (5%-19% increase) in improving screening. Published cost of the interventions was described where available and, when not available, was estimated. Of the 4566 citations reviewed, 38 articles describing 42 interventions met the inclusion criteria. Of the 42 interventions, 16 (38.1%) were categorized as highly effective and 14 (33.3%) as moderately effective. Effective low-cost interventions (<$1000) included the strategic placement of specimen collection materials or automatic collection of STD specimens as part of a routine visit (7 highly effective and 1 moderately effective) and the use of electronic health records (EHRs; 3 highly effective and 4 moderately effective). Patient reminders for screening or rescreening (via text, telephone, and postcards) were highly effective (3) or moderately effective (2) and low or moderate cost (<$1001-10,000). Interventions with dedicated clinic staff to improve STD screening were highly effective (2) or moderately effective in improving STD screening (1) but high-cost ($10,001-$100,000). Successful interventions include changing clinic flow to routinely collect specimens for testing, using EHR screening reminders, and reminding patients to get screened or rescreened. These strategies can be tailored to different clinic settings to improve screening at a low cost.
Analyzing slug tests in wells screened across the watertable: A field assessment
Stanford, K.L.; McElwee, C.D.
2000-01-01
The slug test is the most widely used technique for the in situ estimation of hydraulic conductivity in confined and unconfined formations. Currently, there are no generally accepted methods in the groundwater literature for the analysis of response data from slug tests performed in wells screened across the watertable. A field study was undertaken in an attempt to develop a set of practical guidelines for tests conducted in such wells. Three wells, screened within unconsolidated material exhibiting a range of hydraulic conductivities (.05-30.0 m/day), were installed to depths of up to 9 m (30 ft) in Kansas River alluvium that ranges in thickness from 15 m to 21 m (50 ft to 70 ft) near Lawrence, Kansas. Intensive well-development efforts removed any drilling debris that could interfere with well-formation hydraulics. Once the wells were developed properly, a series of slug tests was performed at each well. The tests were designed to assess the role of the unsaturated zone and the appropriateness of assuming a fixed hydraulic head upper boundary. The results of this investigation can be summarized as follows: (1) the sufficiency of well development should be based on repeat slug tests and not the clarity of pumped water; (2) the effective screen radius for best model analysis should be based on a mass balance and not nominal screen dimensions; (3) the watertable can be represented as a constant head boundary and flow in the unsaturated zone can be ignored in most situations; (4) conventional techniques for the analysis of slug-test data seem to be reasonable for slug tests conducted in wells screened across the watertable, when used with the appropriate effective screen radius and normalized head range; and (5) fluctuations in the watertable elevation through time can be exploited to obtain some insight into the nature of vertical variation in hydraulic conductivity at a well. The results of this investigation indicate that multiple slug tests should be performed at wells screened across the watertable in order to reliably assess the sufficiency of well development and the appropriateness of conventional theory. ?? 2000 International Association for Mathematical Geology.
Apparatus and methods for filtering granular solid material
NASA Technical Reports Server (NTRS)
Backes, Douglas J. (Inventor); Poulter, Clay B. (Inventor); Godfrey, Max R. (Inventor); Tolman, Dennis K. (Inventor); Dutton, Melinda S. (Inventor)
2011-01-01
Apparatuses for screening granular solid particulate material include a generally planar first screen and a second screen. A plurality of apertures extends through the first screen. At least a portion of the second screen is oriented at an angle to the first screen, and apertures extend through a perforated region of the second screen. The second screen includes at least one region configured to prevent at least some particles of solid material from passing through the second screen.
NASA Technical Reports Server (NTRS)
Olson, S. L.
2004-01-01
NASA's current method of material screening determines fire resistance under conditions representing a worst-case for normal gravity flammability - the Upward Flame Propagation Test (Test 1). Its simple pass-fail criteria eliminates materials that burn for more than 12 inches from a standardized ignition source. In addition, if a material drips burning pieces that ignite a flammable fabric below, it fails. The applicability of Test 1 to fires in microgravity and extraterrestrial environments, however, is uncertain because the relationship between this buoyancy-dominated test and actual extraterrestrial fire hazards is not understood. There is compelling evidence that the Test 1 may not be the worst case for spacecraft fires, and we don t have enough information to assess if it is adequate at Lunar or Martian gravity levels.
NASA Technical Reports Server (NTRS)
Olson, S. L.
2004-01-01
NASA s current method of material screening determines fire resistance under conditions representing a worst-case for normal gravity flammability - the Upward Flame Propagation Test (Test 1[1]). Its simple pass-fail criteria eliminates materials that burn for more than 12 inches from a standardized ignition source. In addition, if a material drips burning pieces that ignite a flammable fabric below, it fails. The applicability of Test 1 to fires in microgravity and extraterrestrial environments, however, is uncertain because the relationship between this buoyancy-dominated test and actual extraterrestrial fire hazards is not understood. There is compelling evidence that the Test 1 may not be the worst case for spacecraft fires, and we don t have enough information to assess if it is adequate at Lunar or Martian gravity levels.
Rafkin, Lisa E.; Matheson, Della; Steck, Andrea K.; Yu, Liping; Henderson, Courtney; Beam, Craig A.; Boulware, David C.
2015-01-01
Abstract Background: Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot–based screening to identify islet autoantibody–positive relatives potentially eligible for inclusion in prevention trials. Materials and Methods: Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Results: Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Conclusions: Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies. PMID:26375197
NASA Technical Reports Server (NTRS)
Wingard, Charles Doug; Munafo, Paul M. (Technical Monitor)
2001-01-01
In the International Space Station (ISS), astronauts will convert urine into potable water with the Urine Processor Assembly (UPA). The urine is distilled, with the concentrated form containing about 15% brine solids, and the dilute form as a blend of pre-treated urine/wastewater. Eighteen candidate non-metallic materials for use with the UPA were tested in 2000 for compatibility with the concentrated and dilute urine solutions for continuous times of at least 30 days, and at conditions of 0.5 psia pressure and 100 F, to simulate the working UPA environment. A primary screening test for each material (virgin and conditioned) was dynamic mechanical analysis (DMA) in the stress relaxation mode, with the test data used to predict material performance for a 10-year use in space. Data showed that most of the candidate materials passed the compatibility testing, although a few significant changes in stress relaxation modulus were observed.
Electromagnetic radiation screening of microcircuits for long life applications
NASA Technical Reports Server (NTRS)
Brammer, W. G.; Erickson, J. J.; Levy, M. E.
1974-01-01
The utility of X-rays as a stimulus for screening high reliability semiconductor microcircuits was studied. The theory of the interaction of X-rays with semiconductor materials and devices was considered. Experimental measurements of photovoltages, photocurrents, and effects on specified parameters were made on discrete devices and on microcircuits. The test specimens included discrete devices with certain types of identified flaws and symptoms of flaws, and microcircuits exhibiting deviant electrical behavior. With a necessarily limited sample of test specimens, no useful correlation could be found between the X-ray-induced electrical response and the known or suspected presence of flaws.
Ear swelling test by using laser speckle imaging with a long exposure time
NASA Astrophysics Data System (ADS)
Kalchenko, Vyacheslav; Kuznetsov, Yuri; Preise, Dina; Meglinski, Igor; Harmelin, Alon
2014-06-01
Laser speckle imaging with long exposure time has been applied noninvasively to visualize the immediate reaction of cutaneous vessels in mice in response to a known primary irritant and potential allergen-methyl salicylate. The compound has been used topically on the surface of the pinna and the reaction of the vascular network was examined. We demonstrate that irritant-induced acute vascular reaction can be effectively and accurately detected by laser speckle imaging technique. The current approach holds a great promise for application in routine screening of the cutaneous vascular response induced by contact agents, screenings of mouse ear swelling test, and testing the allergenic potential of new synthetic materials and healthcare pharmaceutical products.
78 FR 54653 - Proposed Data Collections Submitted for Public Comment and Recommendations
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-05
... materials on opinions about CRC screening tests. Each respondent will be randomly assigned to one of three... treatment group that receives a ``No Excuses'' educational flyer designed to dispel many common reasons for... randomly selected from the KN KnowledgePanel[supreg]. A pre-test of study procedures will be conducted...
Lessons learned in preparing method 29 filters for compliance testing audits.
Martz, R F; McCartney, J E; Bursey, J T; Riley, C E
2000-01-01
Companies conducting compliance testing are required to analyze audit samples at the time they collect and analyze the stack samples if audit samples are available. Eastern Research Group (ERG) provides technical support to the EPA's Emission Measurements Center's Stationary Source Audit Program (SSAP) for developing, preparing, and distributing performance evaluation samples and audit materials. These audit samples are requested via the regulatory Agency and include spiked audit materials for EPA Method 29-Metals Emissions from Stationary Sources, as well as other methods. To provide appropriate audit materials to federal, state, tribal, and local governments, as well as agencies performing environmental activities and conducting emission compliance tests, ERG has recently performed testing of blank filter materials and preparation of spiked filters for EPA Method 29. For sampling stationary sources using an EPA Method 29 sampling train, the use of filters without organic binders containing less than 1.3 microg/in.2 of each of the metals to be measured is required. Risk Assessment testing imposes even stricter requirements for clean filter background levels. Three vendor sources of quartz fiber filters were evaluated for background contamination to ensure that audit samples would be prepared using filters with the lowest metal background levels. A procedure was developed to test new filters, and a cleaning procedure was evaluated to see if a greater level of cleanliness could be achieved using an acid rinse with new filters. Background levels for filters supplied by different vendors and within lots of filters from the same vendor showed a wide variation, confirmed through contact with several analytical laboratories that frequently perform EPA Method 29 analyses. It has been necessary to repeat more than one compliance test because of suspect metals background contamination levels. An acid cleaning step produced improvement in contamination level, but the difference was not significant for most of the Method 29 target metals. As a result of our studies, we conclude: Filters for Method 29 testing should be purchased in lots as large as possible. Testing firms should pre-screen new boxes and/or new lots of filters used for Method 29 testing. Random analysis of three filters (top, middle, bottom of the box) from a new box of vendor filters before allowing them to be used in field tests is a prudent approach. A box of filters from a given vendor should be screened, and filters from this screened box should be used both for testing and as field blanks in each test scenario to provide the level of quality assurance required for stationary source testing.
Inorganic separator technology program
NASA Technical Reports Server (NTRS)
Smatko, J. S.; Weaver, R. D.; Kalhammer, F. R.
1973-01-01
Testing and failure analyses of silver zinc cells with largely inorganic separators were performed. The results showed that the wet stand and cycle life objective of the silver-zinc cell development program were essentially accomplished and led to recommendations for cell composition, design, and operation that should yield further improvement in wet and cycle life. A series of advanced inorganic materials was successfully developed and formulated into rigid and semiflexible separator samples. Suitable screening tests for evaluation of largely inorganic separators were selected and modified for application to the separator materials. The results showed that many of these formulations are potentially superior to previously used materials and permitted selection of three promising materials for further evaluation in silver-zinc cells.
Effects of simulant mixed waste on EPDM and butyl rubber
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nigrey, P.J.; Dickens, T.G.
1997-11-01
The authors have developed a Chemical Compatibility Testing Program for the evaluation of plastic packaging components which may be used in transporting mixed waste forms. In this program, they have screened 10 plastic materials in four liquid mixed waste simulants. These plastics were butadiene-acrylonitrile copolymer (Nitrile) rubber, cross-linked polyethylene, epichlorohydrin rubber, ethylene-propylene (EPDM) rubber, fluorocarbons (Viton and Kel-F{trademark}), polytetrafluoro-ethylene (Teflon), high-density polyethylene, isobutylene-isoprene copolymer (Butyl) rubber, polypropylene, and styrene-butadiene (SBR) rubber. The selected simulant mixed wastes were (1) an aqueous alkaline mixture of sodium nitrate and sodium nitrite; (2) a chlorinated hydrocarbon mixture; (3) a simulant liquid scintillation fluid; andmore » (4) a mixture of ketones. The screening testing protocol involved exposing the respective materials to approximately 3 kGy of gamma radiation followed by 14-day exposures to the waste simulants at 60 C. The rubber materials or elastomers were tested using Vapor Transport Rate measurements while the liner materials were tested using specific gravity as a metric. The authors have developed a chemical compatibility program for the evaluation of plastic packaging components which may be incorporated in packaging for transporting mixed waste forms. From the data analyses performed to date, they have identified the thermoplastic, polychlorotrifluoroethylene, as having the greatest chemical compatibility after having been exposed to gamma radiation followed by exposure to the Hanford Tank simulant mixed waste. The most striking observation from this study was the poor performance of polytetrafluoroethylene under these conditions. In the evaluation of the two elastomeric materials they have concluded that while both materials exhibit remarkable resistance to these environmental conditions, EPDM has a greater resistance to this corrosive simulant mixed waste.« less
Real-time and online screening method for materials emitting volatile organic compounds
NASA Astrophysics Data System (ADS)
Kim, Changhyuk; Sul, Yong Tae; Pui, David Y. H.
2016-09-01
In the semiconductor industry, volatile organic compounds (VOCs) in the cleanroom air work as airborne molecular contamination, which reduce the production yield of semiconductor chips by forming nanoparticles and haze on silicon wafers and photomasks under ultraviolet irradiation during photolithography processes. Even though VOCs in outdoor air are removed by gas filters, VOCs can be emitted from many kinds of materials used in cleanrooms, such as organic solvents and construction materials (e.g., adhesives, flame retardants and sealants), threatening the production of semiconductors. Therefore, finding new replacements that emit lower VOCs is now essential in the semiconductor industry. In this study, we developed a real-time and online method to screen materials for developing the replacements by converting VOCs into nanoparticles under soft X-ray irradiation. This screening method was applied to measure VOCs emitted from different kinds of organic solvents and adhesives. Our results showed good repeatability and high sensitivity for VOCs, which come from aromatic compounds, some alcohols and all tested adhesives (Super glue and cleanroom-use adhesives). In addition, the overall trend of measured VOCs from cleanroom-use adhesives was well matched with those measured by a commercial thermal desorption-gas chromatography-mass spectrometry, which is a widely used off-line method for analyzing VOCs. Based on the results, this screening method can help accelerate the developing process for reducing VOCs in cleanrooms.
2006-02-01
further develop modality-independent elastography as a system that is able to reproducibly detect regions of increased stiffness within the breast based...tested on a tissue-like polymer phantom. elastography , breast cancer screening, image processing 16. SECURITY CLASSIFICATION OF: 17. LIMITATION...is a map of the breast (or other tissue of interest) that reflects material inhomogeneity, such as in the case of a tumor mass that disrupts the
Clarke, Nicholas; Gallagher, Pamela; Kearney, Patricia M; McNamara, Deirdre; Sharp, Linda
2016-12-01
Faecal immunochemical tests (FITs) are increasingly being used in population-based colorectal cancer-screening programmes. Uptake of FIT is lower in men than women; however, the reasons for this are not well understood. We aimed to explore gender differences in influences on decisions to participate in FIT screening. This is a qualitative study using in-depth face-to-face interviews of four groups of screening invitees (male and female screening users and male and female screening non-users), purposively sampled from the database of a population-based FIT screening programme. Recruitment continued until saturation was reached. Interviews were audio recorded and transcribed verbatim. Thematic analysis using the framework approach was employed with the theoretical domains framework guiding analysis. Forty-seven screening invitees were interviewed. Six theoretical domains influenced screening uptake: 'environmental context and resources', 'beliefs about capabilities', 'beliefs about consequences', 'emotions', 'social influences' and 'knowledge'. Male non-users were often fatalistic, less knowledgeable and misinformed about cancer and FIT screening compared with other groups. Female non-users expressed negative attitudes, beliefs and emotions towards FIT screening, cancer, social influences and the medical profession and were over-confident about their health. Negative attitudes and emotions to screening dominated non-user decision-making but differed by gender. Opportunities to improve uptake in men and women exist. Greater national discussions on the benefits of FIT screening, and development of screening materials tackling negative attitudes and beliefs while recognising male/female differences, may improve screening uptake. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Technical Note: Some Issues Related to the Selection of Polymers for Aerospace Oxygen Systems
NASA Technical Reports Server (NTRS)
Hirsch, David; Beeson, Harold
2004-01-01
Materials intended for use in aerospace oxygen systems are commonly screened for oxygen compatibility following NASA STD 6001. This standard allows qualification of materials based on results provided by only one test method. Potential issues related to this practice are reviewed and recommendations are proposed that would lead to improved aerospace oxygen systems safety.
Screening of heavy metal containing waste types for use as raw material in Arctic clay-based bricks.
Belmonte, Louise Josefine; Ottosen, Lisbeth M; Kirkelund, Gunvor Marie; Jensen, Pernille Erland; Vestbø, Andreas Peter
2016-11-10
In the vulnerable Arctic environment, the impact of especially hazardous wastes can have severe consequences and the reduction and safe handling of these waste types are therefore an important issue. In this study, two groups of heavy metal containing particulate waste materials, municipal solid waste incineration (MSWI) fly and bottom ashes and mine tailings (i.e., residues from the mineral resource industry) from Greenland were screened in order to determine their suitability as secondary resources in clay-based brick production. Small clay discs, containing 20 or 40% of the different particulate waste materials, were fired and material properties and heavy metal leaching tests were conducted before and after firing. Remediation techniques (washing in distilled water and electrodialytical treatment) applied to the fly ash reduced leaching before firing. The mine tailings and bottom ash brick discs obtained satisfactory densities (1669-2007 kg/m 3 ) and open porosities (27.9-39.9%). In contrast, the fly ash brick discs had low densities (1313-1578 kg/m 3 ) and high open porosities (42.1-51. %). However, leaching tests on crushed brick discs revealed that heavy metals generally became more available after firing for all the investigated materials and that further optimisation is therefore necessary prior to incorporation in bricks.
Selenide isotope generator for the Galileo Mission: SIG thermal insulation evaluaion tests
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1979-06-01
Since the SIG program required the use of very high performance thermal insulation materials in rather severe thermal and environmental conditions, a thorough screening and testing program was performed. Several types of materials were included in the preliminary survey. Most promising were oxide and carbonaceous fibrous insulations, oxide and carbonaceous foamed materials, and multilayer materials with both powder and cloth spacers. The latter were only viable for the vacuum option. In all, over one hundred materials from more than sixty manufacturers were evaluated from literature and manufacturers' data. The list was pared to eighteen candidates in seven basic types, i.e.,more » fibrous microporous SiO/sub 2/, fibrous SiO/sub 2//Al/sub 2/O/sub 3/, fibrous ZrO/sub 2/, fibrous carbon, foamed SiO/sub 2/, foamed carbon, and multilayer. Test results are presented.« less
Gwede, Clement K; Davis, Stacy N; Quinn, Gwendolyn P; Koskan, Alexis M; Ealey, Jamila; Abdulla, Rania; Vadaparampil, Susan T; Elliott, Gloria; Lopez, Diana; Shibata, David; Roetzheim, Richard G; Meade, Cathy D
2013-12-01
Colorectal cancer screening (CRCS) rates are low among men and women who seek health care at federally qualified health centers (FQHCs). This study explores health care providers' perspectives about their patient's motivators and impediments to CRCS and receptivity to preparatory education. A mixed methods design consisting of in-depth interviews, focus groups, and a short survey is used in this study. The participants of this study are 17 health care providers practicing in FQHCs in the Tampa Bay area. Test-specific patient impediments and motivations were identified including fear of abnormal findings, importance of offering less invasive fecal occult blood tests, and need for patient-centered test-specific educational materials in clinics. Opportunities to improve provider practices were identified including providers' reliance on patients' report of symptoms as a cue to recommend CRCS and overemphasis of clinic-based guaiac stool tests. This study adds to the literature on CRCS test-specific motivators and impediments. Providers offered unique approaches for motivating patients to follow through with recommended CRCS and were receptive to in-clinic patient education. Findings readily inform the design of educational materials and interventions to increase CRCS in FQHCs.
NASA Astrophysics Data System (ADS)
Ryan, Shannon; Christiansen, Eric L.
2013-02-01
A series of 66 hypervelocity impact experiments have been performed to assess the potential of various materials (aluminium, titanium, copper, stainless steel, nickel, nickel/chromium, reticulated vitreous carbon, silver, ceramic, aramid, ceramic glass, and carbon fibre) and structures (monolithic plates, open-cell foam, flexible fabrics, rigid meshes) for micrometeoroid and orbital debris (MMOD) shielding. Arranged in various single-, double-, and triple-bumper configurations, screening tests were performed with 0.3175 cm diameter Al2017-T4 spherical projectiles at nominally 6.8 km/s and normal incidence. The top performing shields were identified through target damage assessments and their respective weight. The top performing candidate shield at the screening test condition was found to be a double-bumper configuration with a 0.25 mm thick Al3003 outer bumper, 6.35 mm thick 40 PPI aluminium foam inner bumper, and 1.016 mm thick Al2024-T3 rear wall (equal spacing between bumpers and rear wall). In general, double-bumper candidates with aluminium plate outer bumpers and foam inner bumpers were consistently found to be amongst the top performers. For this impact condition, potential weight savings of at least 47% over conventional all-aluminium Whipple shields are possible by utilizing the investigated materials and structures. The results of this study identify materials and structures of interest for further, more in-depth, impact investigations.
Fabrication and test of inorganic/organic separators. [for silver zinc batteries
NASA Technical Reports Server (NTRS)
Smatko, J. S.
1974-01-01
Completion of testing and failure analysis of MDC 40 Ahr silver zinc cells containing largely inorganic separators was accomplished. The results showed that the wet stand and cycle life objectives of the silver zinc cell development program were accomplished. Building, testing and failure analysis of two plate cells employing three optimum separators selected on the basis of extensive screening tests, was performed. The best separator material as a result of these tests was doped calcium zirconate.
Measuring Permeability of Composite Cryotank Laminants
NASA Technical Reports Server (NTRS)
Oliver, Stanley T.; Selvidge, Shawn; Watwood, Michael C.
2004-01-01
This paper describes a test method developed to identify whether certain materials and material systems are suitable candidates for large pressurized reusable cryogenic tanks intended for use in current and future manned launch systems. It provides a quick way to screen numerous candidate materials for permeability under anticipated loading environments consistent with flight conditions, as well as addressing reusability issues. cryogenic tank, where the major design issue was hydrogen permeability. It was successfully used to evaluate samples subjected to biaxial loading while maintaining test temperatures near liquid hydrogen. After each sample was thermally preconditioned, a cyclic pressure load was applied to simulate the in-plane strain. First permeability was measured while a sample was under load. Then the sample was unloaded and allowed to return to ambient temperature. The test was repeated to simulate reusability, in order to evaluate its effects on material permeability.
Scholtens, Ingrid; Laurensse, Emile; Molenaar, Bonnie; Zaaijer, Stephanie; Gaballo, Heidi; Boleij, Peter; Bak, Arno; Kok, Esther
2013-09-25
Nowadays most animal feed products imported into Europe have a GMO (genetically modified organism) label. This means that they contain European Union (EU)-authorized GMOs. For enforcement of these labeling requirements, it is necessary, with the rising number of EU-authorized GMOs, to perform an increasing number of analyses. In addition to this, it is necessary to test products for the potential presence of EU-unauthorized GMOs. Analysis for EU-authorized and -unauthorized GMOs in animal feed has thus become laborious and expensive. Initial screening steps may reduce the number of GMO identification methods that need to be applied, but with the increasing diversity also screening with GMO elements has become more complex. For the present study, the application of an informative detailed 24-element screening and subsequent identification strategy was applied in 50 animal feed samples. Almost all feed samples were labeled as containing GMO-derived materials. The main goal of the study was therefore to investigate if a detailed screening strategy would reduce the number of subsequent identification analyses. An additional goal was to test the samples in this way for the potential presence of EU-unauthorized GMOs. Finally, to test the robustness of the approach, eight of the samples were tested in a concise interlaboratory study. No significant differences were found between the results of the two laboratories.
TESTING OF TMR SAND MANTIS FINAL REPORT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krementz, D; William Daugherty, W
2007-06-12
Screening tests of Sand Mantis candidate materials selected for erosion resistance have been completed. The results of this testing identified that over a relatively short period of operation (<1 hour), measurable erosion will occur in each of the candidate zoom tube materials given equal operating exposure. Additionally, this testing has shown that erosion of the rubber discharge hose directly downstream of the vehicle could be expected to limit the service life of the discharge hose. On the basis of these test results, SRNL recommends the following; {lg_bullet} redesign of critical system components (e.g., zoom tube, discharge hose) should be conductedmore » to improve system characteristics relative to erosion and capitalize on the results of this testing, {lg_bullet} continued efforts to deploy the Sand Mantis should include testing to better define and optimize operating parameters, and gain an understanding of system dynamics, {lg_bullet} discontinue wear testing with the selected materials pending redesign of critical system components (1st recommendation) and inclusion of other candidate materials. The final selection of additional candidate materials should be made following design changes, but might include a Stellite alloy or zirconia.« less
JOYO-1 Irradiation Test Campaign Technical Close-out, For Information
DOE Office of Scientific and Technical Information (OSTI.GOV)
G. Borges
2006-01-31
The JOYO-1 irradiation testing was designed to screen the irradiation performance of candidate cladding, structural and reflector materials in support of space reactor development. The JOYO-1 designation refers to the first of four planned irradiation tests in the JOYO reactor. Limited irradiated material performance data for the candidate materials exists for the expected Prometheus-1 duration, fluences and temperatures. Materials of interest include fuel element cladding and core materials (refractory metal alloys and silicon carbide (Sic)), vessel and plant structural materials (refractory metal alloys and nickel-base superalloys), and control and reflector materials (BeO). Key issues to be evaluated were long termmore » microstructure and material property stability. The JOYO-1 test campaign was initiated to irradiate a matrix of specimens at prototypical temperatures and fluences anticipated for the Prometheus-1 reactor [Reference (1)]. Enclosures 1 through 9 describe the specimen and temperature monitors/dosimetry fabrication efforts, capsule design, disposition of structural material irradiation rigs, and plans for post-irradiation examination. These enclosures provide a detailed overview of Naval Reactors Prime Contractor Team (NRPCT) progress in specific areas; however, efforts were in various states of completion at the termination of NRPCT involvement with and restructuring of Project Prometheus.« less
Zajac, Ian T; Duncan, Amy C; Flight, Ingrid; Wittert, Gary A; Cole, Stephen R; Young, Graeme P; Wilson, Carlene J; Turnbull, Deborah A
2016-09-01
Male participation in screening for bowel cancer is sub-optimal. Theory-based interventions provide a means of improving screening uptake. To test the efficacy of modifying consumer invitation material in line with continuum and stage theories of health behaviour on screening participation. N = 9216 Australian men aged 50-74 years were randomised to one of four trial arms in a 2 × 2 factorial design randomised controlled trial. Participants received either standard invitation material (control group), or combinations of modified advance-notification and invitation letters. A subsample completed baseline and endpoint behavioural surveys. Participants who received the modified advance notification letter were 12% more likely to screen than those who received the standard version (RR = 1.12, χ(2)(1) = 10.38, p = 0.001). The modified invitation letter did not impact screening uptake (RR = 0.97, χ(2)(1) = 0.63, p = 0.424). No significant changes in psychological variables due to the intervention were observed. Modifications to advance notification letters in line with health behaviour theories significantly improves screening uptake in men. Australian New Zealand Clinical Trials Registry: ACTRN12612001122842 https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=362688. Copyright © 2016 Elsevier Ltd. All rights reserved.
Kim, Dowan; Lee, Eunsu; Lee, Heon Sang; Yoon, Jinhwan
2015-01-01
Glazing for adaptive solar control is the most promising for energy efficient development, because the use of this technology in buildings can be expected to significantly impact energy use and efficiency by screening sunlight that enters a building in summer. To achieve autonomous adjustable transparency, we have developed photothermotropic material system by combining photothermal materials with thermotropic hydrogels. We found that graphene oxide dispersed within a hydrogel matrix effectively converts the photo energy of sunlight into thermal energy, providing the efficient means to trigger transparency of thermotropic hydrogels. Therefore, we could develop switchable glazing of novel photothermotropic mechanism that screen strong sunlight and heat radiation in response to the sunlight intensity, as well as the temperature. Furthermore, in this study, a prototype device was manufactured with developed materials and successfully operated in outdoor testing. PMID:25561372
Effectiveness of common fish screen materials to protect lamprey ammocoetes
Rose, Brien P.; Mesa, Matthew G.
2012-01-01
Understanding the effects of irrigation diversions on populations of Pacific lampreyLampetra tridentata in the Columbia River basin is needed for their recovery. We tested the effectiveness of five common fish screen materials for excluding lamprey ammocoetes: interlock (IL), vertical bar (VB), perforated plate (PP), and 12-gauge and 14-gauge wire cloth (WC12) and (WC14). When fish (28–153 mm) were exposed for 60 min to screen panels perpendicular to an approach velocity of 12 cm/s in a recirculating flume, the percentage of ammocoetes entrained (i.e., passed through the screen) was 26% for the IL, 18% for the PP, 33% for the VB, 62% for the WC14, and 65% for the WC12 screens. For all screens, most fish were entrained within the first 15–20 min. Fish length significantly influenced entrainment, with the PP, VB, and IL screens preventing fish greater than 50–65 mm from entrainment and the WC14 and WC12 screens preventing entrainment of fish greater than 90–110 mm. Fish of all sizes repeatedly became impinged (i.e., contacting the screen for more than 1 s) on the screens, with the frequency of impingement events increasing during the first 5 min and becoming relatively stable thereafter. Impingement ranges were highest on the IL screen (36–62%), lowest on the WC14 and WC12 screens (13–31%), and intermediate on the PP and VB screens (23–54%). However, the WC14 and WC12 screens had fewer and larger fish remaining as time elapsed because so many were entrained. For all screen types, injuries were rare and minor, and no fish died after overnight posttest holding. Our results indicate that wire cloth screens should be replaced, where practical, with perforated plate, vertical bar, or interlocking bar screens to reduce lamprey entrainment at water diversions.
Wear-screening and joint simulation studies vs. materials selection and prosthesis design.
Clarke, I C
1982-01-01
Satisfactory friction and wear performance of orthomedic biomaterials is an essential criterion for both hemiarthroplasty and total joint replacements. This report will chart the clinical historical experience of candidate biomaterials with their wear resistance and compare/contrast these data to experimental test predictions. The latter review will encompass publications dealing with both joint simulators and the more basic friction and wear screening devices. Special consideration will be given to the adequacy of the test protocol, the design of the experimental machines, and the accuracy of the measurement techniques. The discussion will then center on clinical reality vs. experimental adequacy and summarize current developments.
Post-Test Inspection of NASA's Evolutionary Xenon Thruster Long Duration Test Hardware: Ion Optics
NASA Technical Reports Server (NTRS)
Soulas, George C.; Shastry, Rohit
2016-01-01
A Long Duration Test (LDT) was initiated in June 2005 as a part of NASA's Evolutionary Xenon Thruster (NEXT) service life validation approach. Testing was voluntarily terminated in February 2014, with the thruster accumulating 51,184 hours of operation, processing 918 kg of xenon propellant, and delivering 35.5 MN-s of total impulse. The post-test inspection objectives for the ion optics were derived from the original NEXT LDT test objectives, such as service life model validation, and expanded to encompass other goals that included verification of in situ measurements, test issue root causes, and past design changes. The ion optics cold grid gap had decreased only by an average of 7% of pretest center grid gap, so efforts to stabilize NEXT grid gap were largely successful. The upstream screen grid surface exhibited a chamfered erosion pattern. Screen grid thicknesses were = 86% of the estimated pretest thickness, indicating that the screen grid has substantial service life remaining. Deposition was found on the screen aperture walls and downstream surfaces that was primarily composed of grid material and back-sputtered carbon, and this deposition likely caused the minor decreases in screen grid ion transparency during the test. Groove depths had eroded through up to 35% of the accelerator grid thickness. Minimum accelerator aperture diameters increased only by about 5-7% of the pretest values and downstream surface diameters increased by about 24-33% of the pretest diameters. These results suggest that increasing the accelerator aperture diameters, improving manufacturing tolerances, and masking down the perforated diameter to 36 cm were successful in reducing the degree of accelerator aperture erosion at larger radii.
3D mosquito screens to create window double screen traps for mosquito control.
Khattab, Ayman; Jylhä, Kaisa; Hakala, Tomi; Aalto, Mikko; Malima, Robert; Kisinza, William; Honkala, Markku; Nousiainen, Pertti; Meri, Seppo
2017-08-29
Mosquitoes are vectors for many diseases such as malaria. Insecticide-treated bed nets and indoor residual spraying of insecticides are the principal malaria vector control tools used to prevent malaria in the tropics. Other interventions aim at reducing man-vector contact. For example, house screening provides additive or synergistic effects to other implemented measures. We used commercial screen materials made of polyester, polyethylene or polypropylene to design novel mosquito screens that provide remarkable additional benefits to those commonly used in house screening. The novel design is based on a double screen setup made of a screen with 3D geometric structures parallel to a commercial mosquito screen creating a trap between the two screens. Owing to the design of the 3D screen, mosquitoes can penetrate the 3D screen from one side but cannot return through the other side, making it a unidirectional mosquito screen. Therefore, the mosquitoes are trapped inside the double screen system. The permissiveness of both sides of the 3D screens for mosquitoes to pass through was tested in a wind tunnel using the insectary strain of Anopheles stephensi. Among twenty-five tested 3D screen designs, three designs from the cone, prism, or cylinder design groups were the most efficient in acting as unidirectional mosquito screens. The three cone-, prism-, and cylinder-based screens allowed, on average, 92, 75 and 64% of Anopheles stephensi mosquitoes released into the wind tunnel to penetrate the permissive side and 0, 0 and 6% of mosquitoes to escape through the non-permissive side, respectively. A cone-based 3D screen fulfilled the study objective. It allowed capturing 92% of mosquitoes within the double screen setup inside the wind tunnel and blocked 100% from escaping. Thus, the cone-based screen effectively acted as a unidirectional mosquito screen. This 3D screen-based trap design could therefore be used in house screening as a means of avoiding infective bites and reducing mosquito population size.
In Vitro Pulmonary Toxicity of Metal Oxide Nanoparticles
Nanomaterials (NMs) encompass a diversity of materials with unique physicochemical characteristics which raise concerns about their potential risk to human health. Rapid predictive testing methods are needed to characterize NMs health effects as well as to screen and prioritize N...
NASA Technical Reports Server (NTRS)
Strickland, John W.; Davis, S. Eddie
1995-01-01
The elimination of CFC-containing cleaning solvents for oxygen systems has prompted the development of a number of alternative cleaning solvents that must now be evaluated not only for cleanability, but compatibility as well. NASA Handbook 8060.1(NHB 8060.1) establishes the requirements for evaluation, testing, and selection of materials for use in oxygen rich environments. Materials intended for use in space vehicles, specified test facilities, and ground support equipment must meet the requirements of this document. In addition to the requirements of NHB 8060.1 for oxygen service, alternative cleaning solvents must also be evaluated in other areas (such as corrosivity, non-metals compatibility, non-volatile residue contamination, etc.). This paper will discuss the testing requirements of NHB 8060.1 and present preliminary results from early screening tests performed at Marshall Space Flight Center's Materials Combustion Research Facility.
NASA Technical Reports Server (NTRS)
Olson, S. L.; Beeson, H.; Haas, J.
2001-01-01
One of the performance goals for NASA's enterprise of Human Exploration and Development of Space (HEDS) is to develop methods, data bases, and validating tests for material flammability characterization, hazard reduction, and fire detection/suppression strategies for spacecraft and extraterrestrial habitats. This work addresses these needs by applying the fundamental knowledge gained from low stretch experiments to the development of a normal gravity low stretch material flammability test method. The concept of the apparatus being developed uses the low stretch geometry to simulate the conditions of the extraterrestrial environment through proper scaling of the sample dimensions to reduce the buoyant stretch in normal gravity. The apparatus uses controlled forced-air flow to augment the low stretch to levels which simulate Lunar or Martian gravity levels. In addition, the effect of imposed radiant heat flux on material flammability can be studied with the cone heater. After breadboard testing, the apparatus will be integrated into NASA's White Sands Test Facility's Atmosphere-Controlled Cone Calorimeter for evaluation as a new materials screening test method.
Lo, Glen; Scaranelo, Anabel M; Aboras, Hana; Ghai, Sandeep; Kulkarni, Supriya; Fleming, Rachel; Bukhanov, Karina; Crystal, Pavel
2017-10-01
Purpose To evaluate the value of mammography in detecting breast cancer in high-risk women undergoing screening breast magnetic resonance (MR) imaging. Materials and Methods An ethics-approved, retrospective review of prospective databases was performed to identify outcomes of 3934 screening studies (1977 screening MR imaging examinations and 1957 screening mammograms) performed between January 2012 and July 2014 in 1249 high-risk women. Performance measures including recall and cancer detection rates, sensitivity, specificity, and positive predictive values were calculated for both mammography and MR imaging. Results A total of 45 cancers (33 invasive and 12 ductal carcinomas in situ) were diagnosed, 43 were seen with MR imaging and 14 with both mammography and MR imaging. Additional tests (further imaging and/or biopsy) were recommended in 461 screening MR imaging studies (recall rate, 23.3%; 95% confidence interval [CI]: 21.5%, 25.2%), and mammography recalled 217 (recall rate, 11.1%; 95% CI: 9.7%, 12.6%). The cancer detection rate for MR imaging was 21.8 cancers per 1000 examinations (95% CI: 15.78, 29.19) and that for mammography was 7.2 cancers per 1000 examinations (95% CI: 3.92, 11.97; P < .001). Sensitivity and specificity of MR imaging were 96% and 78% respectively, and those of mammography were 31% and 89%, respectively (P < .001). Positive predictive value for MR imaging recalls was 9.3% (95% CI: 6.83%, 12.36%) and that for mammography recalls was 6.5% (95% CI: 3.57%, 10.59%). Conclusion Contemporaneous screening mammography did not have added value in detection of breast cancer for women who undergo screening MR imaging. Routine use of screening mammography in women undergoing screening breast MR imaging warrants reconsideration. © RSNA, 2017 Online supplemental material is available for this article.
Isaacs, Eric B.; Wolverton, Chris
2018-02-26
Electronic band structure contains a wealth of information on the electronic properties of a solid and is routinely computed. However, the more difficult problem of designing a solid with a desired band structure is an outstanding challenge. In order to address this inverse band structure design problem, we devise an approach using materials database screening with materials attributes based on the constituent elements, nominal electron count, crystal structure, and thermodynamics. Our strategy is tested in the context of thermoelectric materials, for which a targeted band structure containing both flat and dispersive components with respect to crystal momentum is highly desirable.more » We screen for thermodynamically stable or metastable compounds containing d 8 transition metals coordinated by anions in a square planar geometry in order to mimic the properties of recently identified oxide thermoelectrics with such a band structure. In doing so, we identify 157 compounds out of a total of over half a million candidates. After further screening based on electronic band gap and structural anisotropy, we explicitly compute the band structures for the several of the candidates in order to validate the approach. We successfully find two new oxide systems that achieve the targeted band structure. Electronic transport calculations on these two compounds, Ba 2PdO 3 and La 4PdO 7, confirm promising thermoelectric power factor behavior for the compounds. This methodology is easily adapted to other targeted band structures and should be widely applicable to a variety of design problems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isaacs, Eric B.; Wolverton, Chris
Electronic band structure contains a wealth of information on the electronic properties of a solid and is routinely computed. However, the more difficult problem of designing a solid with a desired band structure is an outstanding challenge. In order to address this inverse band structure design problem, we devise an approach using materials database screening with materials attributes based on the constituent elements, nominal electron count, crystal structure, and thermodynamics. Our strategy is tested in the context of thermoelectric materials, for which a targeted band structure containing both flat and dispersive components with respect to crystal momentum is highly desirable.more » We screen for thermodynamically stable or metastable compounds containing d 8 transition metals coordinated by anions in a square planar geometry in order to mimic the properties of recently identified oxide thermoelectrics with such a band structure. In doing so, we identify 157 compounds out of a total of over half a million candidates. After further screening based on electronic band gap and structural anisotropy, we explicitly compute the band structures for the several of the candidates in order to validate the approach. We successfully find two new oxide systems that achieve the targeted band structure. Electronic transport calculations on these two compounds, Ba 2PdO 3 and La 4PdO 7, confirm promising thermoelectric power factor behavior for the compounds. This methodology is easily adapted to other targeted band structures and should be widely applicable to a variety of design problems.« less
The Influence of Juggling on Mental Rotation Performance in Children
ERIC Educational Resources Information Center
Jansen, Petra; Lange, Leonie F.; Heil, Martin
2011-01-01
Study aim: To assess the influence of juggling training on mental rotation performance in children. Material and methods: Two groups of girls aged 6-14 years were studied: experimental (EG; n = 26) and control (CG; n = 24). All girls solved a mental rotation task with 3-D block figures on computer screen (pre-test). After the initial test, EG…
Marcus, Alfred C; Mason, Mondi; Wolfe, Pam; Rimer, Barbara K; Lipkus, Isaac; Strecher, Victor; Warneke, Richard; Morra, Marion E; Allen, Amy Reasinger; Davis, Sharon W; Gaier, Amy; Graves, Carlan; Julesberg, Karen; Nguyen, Lynne; Perocchia, Rosemarie; Speyer, Jo Beth; Wagner, Doug; Thomsen, Chris; Bright, Mary Anne
2005-01-01
In this large randomized trial among callers to the Cancer Information Service (CIS), tailored print materials were tested for efficacy in promoting colorectal cancer (CRC) screening (fecal occult blood test [FOBT], flexible sigmoidoscopy, or colonoscopy). All participants completed baseline interviews at the end of their usual service calls to the CIS, as well as short-term (6-month) and longer-term (14-month) telephone follow-up interviews. The study sample (n = 4,014) was restricted to English-speaking CIS callers 50 + years of age, who would be eligible for CRC screening at 14 months follow-up and did not call the CIS about CRC or CRC screening. Four experimental conditions were compared: a single untailored (SU) mailout of print material (the control condition); a single tailored (ST) mailout of print material; four (multiple) tailored (MT) mailouts of print materials spanning 12 months, all of which were tailored to information obtained at baseline; and four (multiple) retailored (MRT) mailouts also spanning 12 months, with retailoring of the print materials (mailouts 2, 3, and 4) based on updated information obtained from the 6-month follow-up interviews. Consistent with the main hypothesis of this trial, a significant linear trend across the SU, ST, MT, and MRT groups was found at 14 months (42%, 44%, 51%, and 48%, respectively, p = 0.05). Only for MT was there a significant difference compared with SU (p = 0.03) for the sample as a whole, while no differences were found for MT vs. MRT at 14 months. Significant moderator effects in the predicted direction were found among females, younger participants, and among those with a history of CRC screening, all of which involved the SU vs. MT MRT comparisons. Only among younger participants (ages 50-59) was there a difference between SU vs. ST at 14 months. Given these results, we conclude from this trial the following: (1) the MRT intervention failed to show added benefit beyond the MT intervention, (2) the significant intervention effects involving the MT and MRT conditions can be explained by tailoring and/or the longitudinal nature of both interventions, and (3) the most compelling evidence in support of tailoring was found for the ST condition among younger participants, where a significant need for interventions exists at the national level. Directions for future research are discussed in light of the results summarized above.
Test-Retest Reliability of a Serious Game for Delirium Screening in the Emergency Department.
Tong, Tiffany; Chignell, Mark; Tierney, Mary C; Lee, Jacques S
2016-01-01
Introduction: Cognitive screening in settings such as emergency departments (ED) is frequently carried out using paper-and-pencil tests that require administration by trained staff. These assessments often compete with other clinical duties and thus may not be routinely administered in these busy settings. Literature has shown that the presence of cognitive impairments such as dementia and delirium are often missed in older ED patients. Failure to recognize delirium can have devastating consequences including increased mortality (Kakuma et al., 2003). Given the demands on emergency staff, an automated cognitive test to screen for delirium onset could be a valuable tool to support delirium prevention and management. In earlier research we examined the concurrent validity of a serious game, and carried out an initial assessment of its potential as a delirium screening tool (Tong et al., 2016). In this paper, we examine the test-retest reliability of the game, as it is an important criterion in a cognitive test for detecting risk of delirium onset. Objective: To demonstrate the test-retest reliability of the screening tool over time in a clinical sample of older emergency patients. A secondary objective is to assess whether there are practice effects that might make game performance unstable over repeated presentations. Materials and Methods: Adults over the age of 70 were recruited from a hospital ED. Each patient played our serious game in an initial session soon after they arrived in the ED, and in follow up sessions conducted at 8-h intervals (for each participant there were up to five follow up sessions, depending on how long the person stayed in the ED). Results: A total of 114 adults (61 females, 53 males) between the ages of 70 and 104 years ( M = 81 years, SD = 7) participated in our study after screening out delirious patients. We observed a test-retest reliability of the serious game (as assessed by correlation r -values) between 0.5 and 0.8 across adjacent sessions. Conclusion: The game-based assessment for cognitive screening has relatively strong test-retest reliability and little evidence of practice effects among elderly emergency patients, and may be a useful supplement to existing cognitive assessment methods.
Evaluation of fuel additives for reduction of material imcompatibilities in methanol-gasoline blends
NASA Technical Reports Server (NTRS)
Rodriguez, C. F.; Barbee, J. G.; Knutson, W. K.; Cuellar, J. P., Jr.
1983-01-01
Screening tests determined the efficacy of six commercially available additives as modifiers of methanol's corrosivity toward metals and its weakening of tensile properties of nonmetals in automotive fuel systems. From the screening phase, three additives which seemed to protect some of the metals were tested in higher concentrations and binary combinations in search of optimal application conditions. Results indicate that two of the additives have protective properties and combining them increases the protection of the metals corroded by methanol-gasoline blends. Half of the metals in the tests were not corroded. Testing at recommended concentrations and then at higher concentrations and in combinations shows that the additives would have no protective or harmful effects on the nonmetals. Two additives emerged as candidates for application to the protection of metals in automotive methanol-gasoline fuel systems. The additives tested were assigned letter codes to protect their proprietary nature.
DC partial discharge/environmental test screening of space TWTS
NASA Astrophysics Data System (ADS)
Hai, F.; Paschen, K. W.
Direct-current partial discharge/environmental tests are being conducted on traveling wave tubes (TWTs) designated for long-term space operation to screen out tubes with high voltage defects. Two types of TWTs with different external high-voltage insulation are being examined: (1) TWTs with polymeric potting, and (2) TWTs with ceramic feedthroughs. Detection of high voltage defects in the form of cracks and seprations in potted systems is enhanced by combining dc partial discharge testing with environmental (temperature and pressure) testing. These defects are usually caused by high stresses in the potting produced during temperature excursions by the difference in thermal expansion between the potting material and the confining ceramic-metal structure. Tests of all-ceramic-insulated TWTs indicate that the high voltage problem is internal to the vacuum envelope and requires both leakage and discharge measurements for diagnosis. This problem appears to be field emission from contaminated surfaces.
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Miller, C. M.
1976-01-01
Rankings of relative toxicity can be markedly affected by changes in test variables. Revision of the USF/NASA toxicity screening test procedure to eliminate the connecting tube and supporting floor and incorporate a 1.0 g sample weight, 200 C starting temperature, and 800 C upper limit temperature for pyrolysis, reversed the rankings of flexible polyurethane and polychloroprene foams, not only in relation to each other, but also in relation to cotton and red oak. Much of the change is attributed to reduction of the distance between the sample and the test animals, and reduction of the sample weight charged. Elimination of the connecting tube increased the relative toxicity of the polyurethane foams. The materials tested were flexible polyurethane foam, without and with fire retardant; rigid polyurethane foam with fire retardant; flexible polychloroprene foam; cotton, Douglas fir, red oak, hemlock, hardboard, particle board, polystyrene, and polymethyl methacrylate.
On the Use of Accelerated Test Methods for Characterization of Advanced Composite Materials
NASA Technical Reports Server (NTRS)
Gates, Thomas S.
2003-01-01
A rational approach to the problem of accelerated testing for material characterization of advanced polymer matrix composites is discussed. The experimental and analytical methods provided should be viewed as a set of tools useful in the screening of material systems for long-term engineering properties in aerospace applications. Consideration is given to long-term exposure in extreme environments that include elevated temperature, reduced temperature, moisture, oxygen, and mechanical load. Analytical formulations useful for predictive models that are based on the principles of time-based superposition are presented. The need for reproducible mechanisms, indicator properties, and real-time data are outlined as well as the methodologies for determining specific aging mechanisms.
NASA Technical Reports Server (NTRS)
Peralta, S.; Rosales, Keisa R.; Stoltzfus, Joel M.
2009-01-01
Metallic contaminant was found in the liquid oxygen (LOX) pre-valve screen of the shuttle main engine propulsion system on two orbiter vehicles. To investigate the potential for an ignition, NASA Johnson Space Center White Sands Test Facility performed (modified) rotating friction ignition testing in LOX. This testing simulated a contaminant particle in the low-pressure oxygen turbo pump (LPOTP) and the high-pressure oxygen turbo pump (HPOTP) of the shuttle main propulsion system. Monel(R) K-500 and Inconel(R) 718 samples represented the LPOTP and HPOTP materials. Aluminum foil tape and titanium foil represented the contaminant particles. In both the Monel(R) and Inconel(R) material configurations, the aluminum foil tape samples did not ignite after 30 s of rubbing. In contrast, all of the titanium foil samples ignited regardless of the rubbing duration or material configuration. However, the titanium foil ignitions did not propagate to the Monel and Inconel materials.
Optical Property Enhancement and Durability Evaluation of Heat Receiver Aperture Shield Materials
NASA Technical Reports Server (NTRS)
deGroh, Kim K.; Jaworske, Donald A.; Smith, Daniela C.
1998-01-01
Under the Solar Dynamic Flight Demonstration (SDFD) program, NASA Lewis Research Center worked with AlliedSignal Aerospace, the heat receiver contractor, on the development, characterization and durability testing of refractory metals to obtain appropriate optical and thermal properties for the SDFD heat receiver aperture shield. Molybdenum and tungsten foils were grit-blasted using silicon carbide or alumina grit under various grit-blasting conditions for optical property enhancement. Black rhenium coated tungsten foil was also evaluated. Tungsten, black rhenium-coated tungsten, and grit-blasted tungsten screens of various mesh sizes were placed over the pristine and grit-blasted foils for optical property characterization. Grit-blasting was found to be effective in decreasing the specular reflectance and the absorptance/emittance ratio of the refractory foils. The placement of a screen further enhanced these optical properties, with a grit-blasted screen over a grit-blasted foil producing the best results. Based on the optical property enhancement results, samples were tested for atomic oxygen and vacuum heat treatment durability. Grit-blasted (Al2O3 grit) 2 mil tungsten foil was chosen for the exterior layer of the SDFD heat receiver aperture shield. A 0.007 in. wire diameter, 20 x 20 mesh tungsten screen was chosen to cover the tungsten foil. Based on these test results, a heat receiver aperture shield test unit has been built with the screen covered grit-blast tungsten foil exterior layers. The aperture shield was tested and verified the thermal and structural durability of the outer foil layers during an off-pointing period.
The impact of tailored interventions on a community health center population.
Rimer, B K; Conaway, M; Lyna, P; Glassman, B; Yarnall, K S; Lipkus, I; Barber, L T
1999-06-01
We conducted a 4-year randomized study in a community health center that serves primarily low income Blacks in Durham, North Carolina. Patients (1318 at baseline) were assigned randomly to one of three study groups: provider prompting intervention alone, provider prompting and tailored print materials or the previous group and tailored telephone counseling. The purpose of the study was to determine whether increasingly intensive, tailored print and telephone interventions also were increasingly effective in promoting adherence to mammograms, Pap tests and overall cancer screening compliance. Thus, the combination of tailored print interventions (print and telephone) should have been more effective than the provider prompting intervention alone, or the print intervention and prompting combination. This is one of the few studies to examine a measure of overall cancer screening compliance and to assess the benefit of combinations of tailored interventions in promoting adherence to cancer screening. Patients gave extremely high ratings to the interventions. At the bivariate level, we found a significant effect of the most intensive group (provider prompting intervention, tailored print communications and tailored telephone counseling) on Pap test compliance (P = 0.05) and borderline significance at the multivariate level (P = 0.06) as well on overall screening compliance (P = 0.06). There was not a significant effect on mammography, probably because a majority of the patients were receiving regular mammograms. We also found some important subgroup differences. For example, a larger proportion of women reported Pap tests in the tailored print and counseling group when they believed the materials were 'meant for me.' These results show that a combination of tailored interventions may have potential for reaching the women who have too often been labeled the 'hard to reach.'
NASA Astrophysics Data System (ADS)
Bateman, Robert; Harris, Adam; Lee, Linda; Howle, Christopher R.; Ackermann, Sarah L. G.
2016-05-01
The paper will review the feasibility of adapting the Modified Transient Plane Source (MTPS) method as a screening tool for early-detection of explosives and hazardous materials. Materials can be distinguished from others based on their inherent thermal properties (e.g. thermal effusivity) in testing through different types of barrier materials. A complimentary advantage to this technique relative to other traditional detection technologies is that it can penetrate reflective barrier materials, such as aluminum, easily. A strong proof-of-principle is presented on application of the MTPS transient thermal property measuring in the early-screening of liquid explosives. The work demonstrates a significant sensitivity to distinguishing a wide range of fluids based on their thermal properties through a barrier material. The work covers various complicating factors to the longer-term adoption of such a method including the impact of carbonization and viscosity. While some technical challenges remain, the technique offers significant advantages in complimenting existing detection methods in being able to penetrate reflective metal containers (e.g. aluminum soft drinkscans) with ease.
Space Environmental Effects on the Optical Properties of Selected Transparent Polymers
NASA Technical Reports Server (NTRS)
Edwards, David L.; Willowby, Douglas J.; Hubbs, Whitney C.; Piszczor, Michael F., Jr.; Bowden, Mary L.
1997-01-01
Transparent polymer films are currently considered for use as solar concentrating lenses for spacecraft power and propulsion systems. These polymer films concentrate solar energy onto energy conversion devices such as solar cells and thermal energy systems. Conversion efficiency is directly related to the polymer transmission. Space environmental effects will decrease the transmission and thus reduce the conversion efficiency. This investigation focuses on the effects of ultraviolet and charged particle radiation on the transmission of selected transparent polymers. Multiple candidate polymer samples were exposed to near ultraviolet (NUV) radiation to screen the materials and select optimum materials for further study. All materials experienced transmission degradation of varying degree. A method was developed to normalize the transmission loss and thus rank the materials according to their tolerance of NUV. Teflon(Tm) FEP and Teflon(Tm) PFA were selected for further study. These materials were subjected to a combined charged particle dose equivalent to 5 years in a typical geosynchronous Earth orbit (GEO). Results from these NUV screening tests and the 5 year GEO equivalent dose are presented.
Heyworth, L; Kleinman, K; Oddleifson, S; Bernstein, L; Frampton, J; Lehrer, M; Salvato, K; Weiss, T W; Simon, S R; Connelly, M
2014-05-01
Guidelines recommend screening for osteoporosis with bone mineral density (BMD) testing in menopausal women, particularly those with additional risk factors for fracture. Many eligible women remain unscreened. This randomized study demonstrates that a single outreach interactive voice response phone call improves rates of BMD screening among high-risk women age 50-64. Osteoporotic fractures are a major cause of disability and mortality. Guidelines recommend screening with BMD for menopausal women, particularly those with additional risk factors for fracture. However, many women remain unscreened. We examined whether telephonic interactive voice response (IVR) or patient mailing could increase rates of BMD testing in high risk, menopausal women. We studied 4,685 women age 50-64 years within a not-for-profit health plan in the United States. All women had risk factors for developing osteoporosis and no prior BMD testing or treatment for osteoporosis. Patients were randomly allocated to usual care, usual care plus IVR, or usual care plus mailed educational materials. To avoid contamination, patients within a single primary care physician practice were randomized to receive the same intervention. The primary endpoint was BMD testing at 12 months. Secondary outcomes included BMD testing at 6 months and medication use at 12 months. Mean age was 57 years. Baseline demographic and clinical characteristics were similar across the three study groups. In adjusted analyses, the incidence of BMD screening was 24.6% in the IVR group compared with 18.6% in the usual care group (P < 0.001). There was no difference between the patient mailing group and the usual care group (P = 0.3). In this large community-based randomized trial of high risk, menopausal women age 50-64, IVR, but not patient mailing, improved rates of BMD screening. IVR remains a viable strategy to incorporate in population screening interventions.
Computer-aided testing of pilot response to critical in-flight events
NASA Technical Reports Server (NTRS)
Giffin, W. C.; Rockwell, T. H.
1984-01-01
This research on pilot response to critical in-flight events employs a unique methodology including an interactive computer-aided scenario-testing system. Navigation displays, instrument-panel displays, and assorted textual material are presented on a touch-sensitive CRT screen. Problem diagnosis scenarios, destination-diversion scenarios and combined destination/diagnostic tests are available. A complete time history of all data inquiries and responses is maintained. Sample results of diagnosis scenarios obtained from testing 38 licensed pilots are presented and discussed.
Proof test and fatigue crack growth modeling on 2024-T3 aluminum alloy
NASA Technical Reports Server (NTRS)
Newman, J. C., Jr.; Poe, C. C., Jr.; Dawicke, D. S.
1990-01-01
Pressure proof testing of aircraft fuselage structures has been suggested as a means of screening critical crack sizes and of extending their useful life. The objective of this paper is to study the proof-test concept and to model the crack-growth process on a ductile material. Simulated proof and operational fatigue life tests have been conducted on cracked panels made of 2024-T3 aluminum alloy sheet material. A fatigue crack-closure model was modified to simulate the proof test and operational fatigue cycling. Using crack-growth rate and resistance-curve data, the model was able to predict crack growth during and after the proof load. These tests and analyses indicate that the proof test increases fatigue life; but the beneficial life, after a 1.33 or 1.5 proof, was less than a few hundred cycles.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steinmann, Vera; Chakraborty, Rupak; Rekemeyer, Paul
2016-11-21
As novel absorber materials are developed and screened for their photovoltaic (PV) properties, the challenge remains to rapidly test promising candidates in high-performing PV devices. There is a need to engineer new compatible device architectures, including the development of novel transparent conductive oxides and buffer layers. Here, we consider the two approaches of a substrate-style and a superstrate-style device architecture for novel thin-film solar cells. We use tin sulfide as a test absorber material. Upon device engineering, we demonstrate new approaches to improve device performance and performance reproducibility.
Chan, Dorothy N S; So, Winnie K W
2015-10-01
To examine the effect that breast and/or cervical cancer screening programmes for ethnic minority women have on their knowledge of and beliefs about breast or cervical cancer and screening, and on their screening intentions and uptake rates. Recommendations are also made for the format and content of such programmes, based on existing evidence. A comprehensive literature search was carried out both manually and by means of five electronic databases. The findings are summarised and synthesised in narrative fashion. The ten RCTs included here were conducted among ethnic minority women in the United States or Canada, where breast or cervical cancer screening programmes have led to improvements in screening intentions, knowledge of cervical cancer and pap test uptake. The Breast Cancer Screening Belief Scale and self-reporting were the methods commonly used to measure outcomes. The shared characteristics of both countries' programmes were that they were theory- and language-based, the instruction took place in a community setting, the materials were culturally relevant, the content highlighted key messages about breast or cervical cancer and screening measures, and there were multiple intervention strategies. Breast or cervical cancer screening programmes in Western countries have demonstrated improvements in knowledge of the disease, screening intentions and pap test uptake, although evidence on the effectiveness of the interventions has been limited. The common characteristics of programmes are identified, but a comprehensive model is still needed to link these characteristics with other factors and mediators influencing outcomes. Copyright © 2015 Elsevier Ltd. All rights reserved.
Schink, Susanne B.; Offergeld, Ruth; Schmidt, Axel J.; Marcus, Ulrich
2018-01-01
Background The predominant mode of transmission of human immunodeficiency virus (HIV) in Europe is male-to-male transmission. Men who have sex with men (MSM) are deferred from donating blood in many countries, but nevertheless do donate blood. Based on data from 34 countries, we estimated the proportion of MSM screened for HIV in the context of a blood donation and identified individual factors associated with this HIV screening in order to propose possible public health interventions. Materials and methods In 2010, the first European MSM Internet Survey (EMIS) collected self-reported data on HIV testing from >180,000 MSM in 38 European countries. Using logistic regression, demographic and behavioural factors associated with screening for HIV in blood establishments were identified. Stratified by European sub-region, we analysed the proportion of MSM screening in blood establishments by time elapsed since last negative HIV test. Results Donor eligibility criteria for MSM vary across Europe with most countries using permanent deferral. The Western region had the lowest (2%) proportion of MSM screened in blood establishments and the Northeastern region had the highest (14%). Being <25 years old, not disclosing sexual attraction to men, never having had anal intercourse with a man, having a female partner, living in a rural area, and certain European sub-regions or countries of residence increased the likelihood of being screened in blood establishments. Discussion In spite of deferral policies, MSM are screened for HIV in the context of blood donations. Gay-friendly testing services are rare in rural areas, and young men might be reluctant to disclose their sexual orientation. Recent developments, such as home sampling, might offer new testing possibilities for those not reached by established services yet wishing to know their HIV status. Donor selection procedures should be improved. Both interventions might help to further reduce the risk of transfusion-transmitted infections. PMID:28488974
NASA Technical Reports Server (NTRS)
Wingard, Charles Doug; Munafo, Paul M. (Technical Monitor)
2002-01-01
Protein crystals are grown in microgravity experiments inside the Space Shuttle during orbit. Such crystals are basically grown in a five-component system containing a salt, buffer, polymer, organic and water. During these experiments, a number of different polymeric containment materials must be compatible with up to hundreds of different PCG solutions in various concentrations for durations up to 180 days. When such compatibility experiments are performed at NASA/MSFC (Marshall Space Flight Center) simultaneously on containment material samples immersed in various solutions in vials, the samples are rather small out of necessity. DMA4 modulus was often used as the primary screening parameter for such small samples as a pass/fail criterion for incompatibility issues. In particular, the TA Instruments DMA 2980 film tension clamp was used to test rubber O-rings as small in I.D. as 0.091 in. by cutting through the cross-section at one place, then clamping the stretched linear cord stock at each end. The film tension clamp was also used to successfully test short length samples of medical/surgical grade tubing with an O.D. of 0.125 in.
Socio-Cognitive Determinants of the Mammography Screening Uptake among Iranian Women
Mirzaei-Alavijeh, Mehdi; Ghorbani, Parvaneh; Jalilian, Farzad
2018-05-26
Background: Mammography screening uptake is the most effective method in breast cancer screening. The aim of this study was to determine the determinants related to mammography screening uptake among Iranian women based on the theory of planned behavior. Materials and Methods: This cross-sectional study was conducted among 408 women who referred to health centers in Kermanshah city, the western of Iran, during 2016. Participants filled out a self-administered questionnaire. Data were analyzed by SPSS version 21 using Pearson correlation, linear and logistic regression statistical tests at 95% significant level. Results: The mean age of participants was 39.61 years [SD: 8.28], ranged from 30 to 60 years. Almost 13% of the participants had already mammography screening uptake at least once. Perceived behavioral control (OR=1.229) and behavioral intention (OR=1.283) were the more influential predictors on mammography screening uptake. Conclusions: Based on result, it seems increase perceived behavior control toward mammography screening uptake may be usefulness in promotion of mammography screening uptake among Iranian women. Creative Commons Attribution License
High temperature ultrasonic sensor for fission gas characterization in MTR harsh environment
NASA Astrophysics Data System (ADS)
Gatsa, O.; Combette, P.; Rozenkrantz, E.; Fourmentel, D.; Destouches, C.; Ferrandis, J. Y. AD(; )
2018-01-01
In the contemporary world, the measurements in hostile environment is one of the predominant necessity for automotive, aerospace, metallurgy and nuclear plant. The measurement of different parameters in experimental reactors is an important point in nuclear power strategy. In the near past, IES (Institut d'Électronique et des Systèmes) on collaboration with CEA (Commissariat à l'Energie Atomique et aux Energies Alternatives) have developed the first ultrasonic sensor for the application of gas quantity determination that has been tested in a Materials Testing Reactor (MTR). Modern requirements state to labor with the materials that possess stability on its parameters around 350°C in operation temperature. Previous work on PZT components elaboration by screen printing method established the new basis in thick film fabrication and characterization in our laboratory. Our trials on Bismuth Titanate ceramics showed the difficulties related to high electrical conductivity of fabricated samples that postponed further research on this material. Among piezoceramics, the requirements on finding an alternative solution on ceramics that might be easily polarized and fabricated by screen printing approach were resolved by the fabrication of thick film from Sodium Bismuth Titanate (NBT) piezoelectric powder. This material exhibits high Curie temperature, relatively good piezoelectric and coupling coefficients, and it stands to be a good solution for the anticipated application. In this paper, we present NBT thick film fabrication by screen printing, characterization of piezoelectric, dielectric properties and material parameters studies in dependence of temperature. Relatively high resistivity in the range of 1.1013 Ohm.cm for fabricated thick film is explained by Aurivillius structure in which a-and b-layers form perovskite structure between oxides of c-layer. Main results of this study are presented and discussed in terms of feasibility for an application to a new sensor device operating at high temperature level (400°). Piezoelectric parameters enhancement and loss reduction at elevated temperatures are envisaged to be optimized. Further sensor development and test in MTR are expected to be realized in the near future.
Screening of lipid composition for scalable fabrication of solvent free lipid microarrays
NASA Astrophysics Data System (ADS)
Ghazanfari, Lida; Lenhert, Steven
2016-12-01
Liquid microdroplet arrays on surfaces are a promising approach to the miniaturization of laboratory processes such as high throughput screening. The fluid nature of these droplets poses unique challenges and opportunities in their fabrication and application, particularly for the scalable integration of multiple materials over large areas and immersion into cell culture solution. Here we use pin spotting and nanointaglio printing to screen a library of lipids and their mixtures for their compatibility with these fabrication processes, as well as stability upon immersion into aqueous solution. More than 200 combinations of natural and synthetic oils composed of fatty acids, triglycerides, and hydrocarbons were tested for their pin-spotting and nanointaglio print quality and their ability to contain the fluorescent compound TRITC upon immersion in water. A combination of castor oil and hexanoic acid at the ratio of 1:1 (w/w) was found optimal for producing reproducible patterns that are stable upon immersion into water. This method is capable of large scale nano-materials integration.
A high throughput mechanical screening device for cartilage tissue engineering.
Mohanraj, Bhavana; Hou, Chieh; Meloni, Gregory R; Cosgrove, Brian D; Dodge, George R; Mauck, Robert L
2014-06-27
Articular cartilage enables efficient and near-frictionless load transmission, but suffers from poor inherent healing capacity. As such, cartilage tissue engineering strategies have focused on mimicking both compositional and mechanical properties of native tissue in order to provide effective repair materials for the treatment of damaged or degenerated joint surfaces. However, given the large number design parameters available (e.g. cell sources, scaffold designs, and growth factors), it is difficult to conduct combinatorial experiments of engineered cartilage. This is particularly exacerbated when mechanical properties are a primary outcome, given the long time required for testing of individual samples. High throughput screening is utilized widely in the pharmaceutical industry to rapidly and cost-effectively assess the effects of thousands of compounds for therapeutic discovery. Here we adapted this approach to develop a high throughput mechanical screening (HTMS) system capable of measuring the mechanical properties of up to 48 materials simultaneously. The HTMS device was validated by testing various biomaterials and engineered cartilage constructs and by comparing the HTMS results to those derived from conventional single sample compression tests. Further evaluation showed that the HTMS system was capable of distinguishing and identifying 'hits', or factors that influence the degree of tissue maturation. Future iterations of this device will focus on reducing data variability, increasing force sensitivity and range, as well as scaling-up to even larger (96-well) formats. This HTMS device provides a novel tool for cartilage tissue engineering, freeing experimental design from the limitations of mechanical testing throughput. © 2013 Published by Elsevier Ltd.
Morimoto, Yasuo; Izumi, Hiroto; Yoshiura, Yukiko; Fujisawa, Yuri; Fujita, Katsuhide
Inhalation tests are the gold standard test for the estimation of the pulmonary toxicity of respirable materials. Intratracheal instillation tests have been used widely, but they yield limited evidence of the harmful effects of respirable materials. We reviewed the effectiveness of intratracheal instillation tests for estimating the hazards of nanomaterials, mainly using research papers featuring intratracheal instillation and inhalation tests centered on a Japanese national project. Compared to inhalation tests, intratracheal instillation tests induced more acute inflammatory responses in the animal lung due to a bolus effect regardless of the toxicity of the nanomaterials. However, nanomaterials with high toxicity induced persistent inflammation in the chronic phase, and nanomaterials with low toxicity induced only transient inflammation. Therefore, in order to estimate the harmful effects of a nanomaterial, an observation period of 3 months or 6 months following intratracheal instillation is necessary. Among the endpoints of pulmonary toxicity, cell count and percentage of neutrophil, chemokines for neutrophils and macrophages, and oxidative stress markers are considered most important. These markers show persistent and transient responses in the lung from nanomaterials with high and low toxicity, respectively. If the evaluation of the pulmonary toxicity of nanomaterials is performed in not only the acute but also the chronic phase in order to avoid the bolus effect of intratracheal instillation and inflammatory-related factors that are used as endpoints of pulmonary toxicity, we speculate that intratracheal instillation tests can be useful for screening for the identification of the hazard of nanomaterials through pulmonary inflammation.
Computational materials design of crystalline solids.
Butler, Keith T; Frost, Jarvist M; Skelton, Jonathan M; Svane, Katrine L; Walsh, Aron
2016-11-07
The modelling of materials properties and processes from first principles is becoming sufficiently accurate as to facilitate the design and testing of new systems in silico. Computational materials science is both valuable and increasingly necessary for developing novel functional materials and composites that meet the requirements of next-generation technology. A range of simulation techniques are being developed and applied to problems related to materials for energy generation, storage and conversion including solar cells, nuclear reactors, batteries, fuel cells, and catalytic systems. Such techniques may combine crystal-structure prediction (global optimisation), data mining (materials informatics) and high-throughput screening with elements of machine learning. We explore the development process associated with computational materials design, from setting the requirements and descriptors to the development and testing of new materials. As a case study, we critically review progress in the fields of thermoelectrics and photovoltaics, including the simulation of lattice thermal conductivity and the search for Pb-free hybrid halide perovskites. Finally, a number of universal chemical-design principles are advanced.
Development of COPVS for High pressure, In-Space, Cryogenic Fuel Storage
NASA Technical Reports Server (NTRS)
DeLay, Tom; Schneider, Judy; Dyess, Mark; Hastings, Chad; Noorda, Ryan; Noorda, Jared; Patterson, James
2008-01-01
Polymeric composite overwrapped pressure vessels (COPVs) provide an attractive material system to support developing commercial launch business and alternate fuel ventures. However to be able to design with these materials, the mechanical behavior of the materials must be understood with regards to processing, performance, damage tolerance, and environment. For the storage of cryogenic propellants, it is important to evaluate the materials performance and impact damage resistance at cryogenic temperatures in order to minimize weight and to ensure safety and reliability. To evaluate the ultimate performance, various polymeric COPV's have been statically burst tested at cryogenic conditions before and after exposure to irradiation. Materials selected for these COPVs were based on the measured mechanical properties of candidate resin systems and fibers that were also tested at cryogenic conditions before and after exposure to irradiation. The correlation of COPV burst pressures with the constituent material properties has proven to be a valuable screening method for selection of suitable candidate materials with resistance to material degradation due to exposure to temperature and radiation.
NASA Technical Reports Server (NTRS)
Ludewig, M.; Omori, S.; Rao, G. L.
1974-01-01
Tests were conducted to determine the experimental pressure drop and velocity data for water flowing through woven screens. The types of materials used are dutch twill and square weave fabrics. Pressure drop measures were made at four locations in a rectangular channel. The data are presented as change in pressure compared with the average entry velocity and the numerical relationship is determined by dividing the volumetric flow rate by the screen area open to flow. The equations of continuity and momentum are presented. A computer program listing an extension of a theoretical model and data from that computer program are included.
SDU6 Interior Liner Testing & Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Skidmore, T. E.
Two liner materials (Marseal® M-3500 and REMA Chemoline® 4CN) proposed for use as a liner inside the Saltstone Disposal Unit 6 (SDU6) were subjected to specific ASTM tests (tensile and lap-shear) after immersion in 50% and 100% simulant solutions for 1000 hours at the Savannah River Ecology Laboratory. Both liner materials exhibited good resistance to the simulant chemistry, at least based on the tests performed and the test duration/conditions imposed. In lap-shear tests, both materials failed in the base material rather than peeling apart, confirming good adhesion. The REMA 4CN bromobutyl elastomer showed superior bonding characteristics and absence of warpingmore » or delamination at the conditions tested. The Marseal M-3500 material (PVC/EVA blend with polyester reinforcement) exhibited deformation and debonding in some locations. The cause of the deformation and delamination observed in the Marseal M-3500 material is not fully known, but possibly attributed to thermomechanical stress at immersion temperatures, and the thermoplastic nature of the material. The immersion temperature (68 °C) is slightly greater than the maximum use temperature limit quoted for the Marseal M- 3500 liner (65 °C), though the basis for the service limit is unknown. The testing performed was limited in scope and only for these two liner materials. These tests were primarily performed to screen for severe incompatibility or short-term degradation in Saltstone bleedwater simulants at bounding solution temperatures. Additional testing is recommended to assess long-term performance and the overall service life of the liner.« less
The design principles of axilla deodorant fragrances.
McGee, T; Rankin, K M; Baydar, A
1998-11-30
There are a number of ways that deodorant products control malodor: a) by suppressing sweat, b) by inhibiting bacterial activity, and c) by covering malodor. The paper focuses on the Givaudan Roure methodology used to develop fragrances that effectively cover malodor. Several steps are involved in the development of a successful deodorant fragrance. First, we test for substantivity of the deodorant fragrance material in the axilla, using odor value technology. Second, using an in vitro test with reconstituted axilla odor, we determine the effectiveness of the substantive fragrance material with carefully screened panelists. Third, using a multichannel olfactive blender, the perfumer creates a fragrance heart with effective deodorant fragrance materials that cover malodor in the vapor phase. Finally, the hedonically pleasing heart is used to create the final fragrance, which is then optimized using our in vitro test method.
Tian, Chenlu; Champlin, Sara; Mackert, Michael; Lazard, Allison; Agrawal, Deepak
2014-08-01
Colorectal cancer (CRC) screening rates in the Unites States are still below target level. Web-based patient education materials are used by patients and providers to provide supplemental information on CRC screening. Low literacy levels and patient perceptions are significant barriers to screening. There are little data on the quality of these online materials from a health literacy standpoint or whether they address patients' perceptions. To evaluate the readability, suitability, and health content of web-based patient education materials on colon cancer screening. Descriptive study. Web-based patient materials. Twelve reputable and popular online patient education materials were evaluated. Readability was measured by using the Flesch-Kincaid Reading Grade Level, and suitability was determined by the Suitability Assessment of Materials, a scale that considers characteristics such as content, graphics, layout/typography, and learning stimulation. Health content was evaluated within the framework of the Health Belief Model, a behavioral model that relates patients' perceptions of susceptibility to disease, severity, and benefits and barriers to their medical decisions. Each material was scored independently by 3 reviewers. Flesch-Kincaid Reading Grade Level score, Suitability Assessment of Materials score, health content score. Readability for 10 of 12 materials surpassed the maximum recommended sixth-grade reading level. Five were 10th grade level and above. Only 1 of 12 materials received a superior suitability score; 3 materials received inadequate scores. Health content analysis revealed that only 50% of the resources discussed CRC risk in the general population and <25% specifically addressed patients at high risk, such as African Americans, smokers, patients with diabetes, and obese patients. For perceived barriers to screening, only 8.3% of resources discussed embarrassment, 25% discussed pain with colonoscopy, 25% addressed cost of colonoscopy, and none specifically mentioned the need to get colonoscopy when no symptoms are present. No material discussed the social benefits of screening. Descriptive design. Most online patient education materials for CRC screening are written beyond the recommended sixth-grade reading level, with suboptimal suitability. Health content is lacking in addressing key perceived risks, barriers, and benefits to CRC screening. Developing more appropriate and targeted patient education resources on CRC may improve patient understanding and promote screening. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
NEL, ANDRE; XIA, TIAN; MENG, HUAN; WANG, XIANG; LIN, SIJIE; JI, ZHAOXIA; ZHANG, HAIYUAN
2014-01-01
Conspectus The production of engineered nanomaterials (ENMs) is a scientific breakthrough in material design and the development of new consumer products. While the successful implementation of nanotechnology is important for the growth of the global economy, we also need to consider the possible environmental health and safety (EHS) impact as a result of the novel physicochemical properties that could generate hazardous biological outcomes. In order to assess ENM hazard, reliable and reproducible screening approaches are needed to test the basic materials as well as nano-enabled products. A platform is required to investigate the potentially endless number of bio-physicochemical interactions at the nano/bio interface, in response to which we have developed a predictive toxicological approach. We define a predictive toxicological approach as the use of mechanisms-based high throughput screening in vitro to make predictions about the physicochemical properties of ENMs that may lead to the generation of pathology or disease outcomes in vivo. The in vivo results are used to validate and improve the in vitro high throughput screening (HTS) and to establish structure-activity relationships (SARs) that allow hazard ranking and modeling by an appropriate combination of in vitro and in vivo testing. This notion is in agreement with the landmark 2007 report from the US National Academy of Sciences, “Toxicity Testing in the 21st Century: A Vision and a Strategy” (http://www.nap.edu/catalog.php?record_id=11970), which advocates increased efficiency of toxicity testing by transitioning from qualitative, descriptive animal testing to quantitative, mechanistic and pathway-based toxicity testing in human cells or cell lines using high throughput approaches. Accordingly, we have implemented HTS approaches to screen compositional and combinatorial ENM libraries to develop hazard ranking and structure-activity relationships that can be used for predicting in vivo injury outcomes. This predictive approach allows the bulk of the screening analysis and high volume data generation to be carried out in vitro, following which limited, but critical, validation studies are carried out in animals or whole organisms. Risk reduction in the exposed human or environmental populations can then focus on limiting or avoiding exposures that trigger these toxicological responses as well as implementing safer design of potentially hazardous ENMs. In this communication, we review the tools required for establishing predictive toxicology paradigms to assess inhalation and environmental toxicological scenarios through the use of compositional and combinatorial ENM libraries, mechanism-based HTS assays, hazard ranking and development of nano-SARs. We will discuss the major injury paradigms that have emerged based on specific ENM properties, as well as describing the safer design of ZnO nanoparticles based on characterization of dissolution chemistry as a major predictor of toxicity. PMID:22676423
Design, fabrication and testing of porous tungsten vaporizers for mercury ion thrusters
NASA Technical Reports Server (NTRS)
Zavesky, R.; Kroeger, E.; Kami, S.
1983-01-01
The dispersions in the characteristics, performance and reliability of vaporizers for early model 30-cm thrusters were investigated. The purpose of the paper is to explore the findings and to discuss the approaches that were taken to reduce the observed dispersion and present the results of a program which validated those approaches. The information that is presented includes porous tungsten materials specifications, a discussion of assembly procedures, and a description of a test program which screens both material and fabrication processes. There are five appendices providing additional detail in the areas of vaporizer contamination, nitrogen flow testing, bubble testing, porosimeter testing, and mercury purity. Four neutralizers, seven cathodes and five main vaporizers were successfully fabricated, tested, and operated on thrusters. Performance data from those devices is presented and indicates extremely repeatable results from using the design and fabrication procedures.
Development of a polymetric grout for the hydrostatic bearing at DSS 14
NASA Technical Reports Server (NTRS)
Mcclung, C. E.; Schwendeman, J. L.; Ball, G. L., III; Jenkins, G. H.; Casperson, R. D.; Gale, G. P.; Riewe, A. A.
1981-01-01
Results of an investigation into the causes of the deterioration and premature failure of the grout under the hydrostatic bearing runner at DSS 14 are reported. Generic types of materials were screened and tested to find a grout material more resistive to the causes of grout failure. Emphasis was placed on the physical properties, strength, modulus of elasticity, and resistance to erosion and chemical attack by oil and unique requirements imposed by each material for mixing, placing, compacting, and cooling. The polymetric grout developed to replace the dry grout is described.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simmons, Kevin L.; Fifield, Leonard S.; Westman, Matthew P.
The goal of this project is to conceptually demonstrate techniques to repair cables that have degraded through subjection to long-term thermal and radiation exposure in nuclear power plants. In fiscal year 2014 (FY14) we focused on commercially available ethylene-propylene rubber (EPR) as the relevant test material, isolated a high surface area form of the EPR material to facilitate chemical treatment screening and charaterization, and measured chemical changes in the material due to aging and treatment using Fourier Transfrom Infrared (FTIR) spectroscopy.
Validity of Single-Item Screening for Limited Health Literacy in English and Spanish Speakers.
Bishop, Wendy Pechero; Craddock Lee, Simon J; Skinner, Celette Sugg; Jones, Tiffany M; McCallister, Katharine; Tiro, Jasmin A
2016-05-01
To evaluate 3 single-item screening measures for limited health literacy in a community-based population of English and Spanish speakers. We recruited 324 English and 314 Spanish speakers from a community research registry in Dallas, Texas, enrolled between 2009 and 2012. We used 3 screening measures: (1) How would you rate your ability to read?; (2) How confident are you filling out medical forms by yourself?; and (3) How often do you have someone help you read hospital materials? In analyses stratified by language, we used area under the receiver operating characteristic (AUROC) curves to compare each item with the validated 40-item Short Test of Functional Health Literacy in Adults. For English speakers, no difference was seen among the items. For Spanish speakers, "ability to read" identified inadequate literacy better than "help reading hospital materials" (AUROC curve = 0.76 vs 0.65; P = .019). The "ability to read" item performed the best, supporting use as a screening tool in safety-net systems caring for diverse populations. Future studies should investigate how to implement brief measures in safety-net settings and whether highlighting health literacy level influences providers' communication practices and patient outcomes.
Snowsill, Tristan; Coelho, Helen; Huxley, Nicola; Jones-Hughes, Tracey; Briscoe, Simon; Frayling, Ian M; Hyde, Chris
2017-09-01
Inherited mutations in deoxyribonucleic acid (DNA) mismatch repair (MMR) genes lead to an increased risk of colorectal cancer (CRC), gynaecological cancers and other cancers, known as Lynch syndrome (LS). Risk-reducing interventions can be offered to individuals with known LS-causing mutations. The mutations can be identified by comprehensive testing of the MMR genes, but this would be prohibitively expensive in the general population. Tumour-based tests - microsatellite instability (MSI) and MMR immunohistochemistry (IHC) - are used in CRC patients to identify individuals at high risk of LS for genetic testing. MLH1 (MutL homologue 1) promoter methylation and BRAF V600E testing can be conducted on tumour material to rule out certain sporadic cancers. To investigate whether testing for LS in CRC patients using MSI or IHC (with or without MLH1 promoter methylation testing and BRAF V600E testing) is clinically effective (in terms of identifying Lynch syndrome and improving outcomes for patients) and represents a cost-effective use of NHS resources. Systematic reviews were conducted of the published literature on diagnostic test accuracy studies of MSI and/or IHC testing for LS, end-to-end studies of screening for LS in CRC patients and economic evaluations of screening for LS in CRC patients. A model-based economic evaluation was conducted to extrapolate long-term outcomes from the results of the diagnostic test accuracy review. The model was extended from a model previously developed by the authors. Ten studies were identified that evaluated the diagnostic test accuracy of MSI and/or IHC testing for identifying LS in CRC patients. For MSI testing, sensitivity ranged from 66.7% to 100.0% and specificity ranged from 61.1% to 92.5%. For IHC, sensitivity ranged from 80.8% to 100.0% and specificity ranged from 80.5% to 91.9%. When tumours showing low levels of MSI were treated as a positive result, the sensitivity of MSI testing increased but specificity fell. No end-to-end studies of screening for LS in CRC patients were identified. Nine economic evaluations of screening for LS in CRC were identified. None of the included studies fully matched the decision problem and hence a new economic evaluation was required. The base-case results in the economic evaluation suggest that screening for LS in CRC patients using IHC, BRAF V600E and MLH1 promoter methylation testing would be cost-effective at a threshold of £20,000 per quality-adjusted life-year (QALY). The incremental cost-effectiveness ratio for this strategy was £11,008 per QALY compared with no screening. Screening without tumour tests is not predicted to be cost-effective. Most of the diagnostic test accuracy studies identified were rated as having a risk of bias or were conducted in unrepresentative samples. There was no direct evidence that screening improves long-term outcomes. No probabilistic sensitivity analysis was conducted. Systematic review evidence suggests that MSI- and IHC-based testing can be used to identify LS in CRC patients, although there was heterogeneity in the methods used in the studies identified and the results of the studies. There was no high-quality empirical evidence that screening improves long-term outcomes and so an evidence linkage approach using modelling was necessary. Key determinants of whether or not screening is cost-effective are the accuracy of tumour-based tests, CRC risk without surveillance, the number of relatives identified for cascade testing, colonoscopic surveillance effectiveness and the acceptance of genetic testing. Future work should investigate screening for more causes of hereditary CRC and screening for LS in endometrial cancer patients. This study is registered as PROSPERO CRD42016033879. The National Institute for Health Research Health Technology Assessment programme.
Colorectal cancer screening patient education materials-how effective is online health information?
John, Elizabeth Sheena; John, Ann M; Hansberry, David R; Thomas, Prashant J; Agarwal, Prateek; Deitch, Christopher; Chokhavatia, Sita
2016-12-01
Patients screened for colorectal cancer (CRC) frequently turn to the Internet to improve their understanding of tests used for detection, including colonoscopy, flexible sigmoidoscopy, fecal occult blood test (FOBT), and CT colonography. It was of interest to determine the quality and readability levels of online health information. The screening tools were googled, and the top 20 results of each test were analyzed for readability, accessibility, usability, and reliability. The 80 articles excluded scientific literature and blogs. We used ten validated readability scales to measure grade levels, and one-way ANOVA and Tukey's honestly statistical different (HSD) post hoc analyses to determine any statistically significant differences among the four diagnostic tests. The LIDA tool assessed overall quality by measuring accessibility, usability, and reliability. The 80 articles were written at an 11.7 grade level, with CT colonography articles written at significantly higher levels than FOBT articles, F(3, 75) = 3.07, p = 0.033. LIDA showed moderate percentages in accessibility (83.9 %), usability (73.0 %), and reliability (75.9 %). Online health information about CRC screening tools are written at higher levels than the National Institute of Health (NIH) and American Medical Association (AMA) recommended third to seventh grade levels. More patients could benefit from this modality of information if it were written at a level and quality that would better facilitate understanding.
Test Plan. GCPS Task 4, subtask 4.2 thrust structure development
NASA Astrophysics Data System (ADS)
Greenberg, H. S.
1994-09-01
The Single Stage To Orbit (SSTO) vehicle is designed to lift off from a vertical position, go into orbit, return to earth for a horizontal landing, and be reusable for the next mission. (NASA baseline only) In order to meet its performance goals, the SSTO relies on light weight structure and the use of 8 tri-propellant engines. These engines are mounted to the thrust structure. This test plan addresses selection of the material for this structure, and the integrity of the design through testing of elements and a full-scale subcomponent. This test plan supports the development of the design for an advanced composite thrust structure for a Single Stage to Orbit manned, heavy launch vehicle. The thrust structure is designed to transmit very high thrust loads from the engines to the rest of the vehicle (see Figure 1 ). The thrust structure will also be used for primary attachment of the twin vertical tails and possibly act as the aft attach point for the wing. The combination of high loading, high vibration, long service life and high acoustic environments will need to be evaluated by tests. To minimize design risk, a building block approach will be used. We will first screen materials to determine which materials show the most promise for this application. Factors in this screening will be the suitability of these materials for chosen design concepts, particularly concerning specific strength, environmental compatibility and applicability to fabrication processes. Next we will characterize two material systems that will be used in the design; the characterization will allow us to generate preliminary design data that will be used for the analysis. Element testing will be performed to evaluate critical structural locations under load. Final testing on the full scale test article will be performed to verify the design and to demonstrate predictability of the analysis. Additionally, risks associated with fabricating full scale thrust structures will be reduced through testing activities. One of the major concerns that stems from full scale fabrication is the realities of size and the associated complexities of handling, manufacturing, and assembly. The need exists to fabricate, assemble and test_representative joint specimens to achieve_confidence in the design and manufacturing technologies being proposed.
Test Plan. GCPS Task 4, subtask 4.2 thrust structure development
NASA Technical Reports Server (NTRS)
Greenberg, H. S.
1994-01-01
The Single Stage To Orbit (SSTO) vehicle is designed to lift off from a vertical position, go into orbit, return to earth for a horizontal landing, and be reusable for the next mission. (NASA baseline only) In order to meet its performance goals, the SSTO relies on light weight structure and the use of 8 tri-propellant engines. These engines are mounted to the thrust structure. This test plan addresses selection of the material for this structure, and the integrity of the design through testing of elements and a full-scale subcomponent. This test plan supports the development of the design for an advanced composite thrust structure for a Single Stage to Orbit manned, heavy launch vehicle. The thrust structure is designed to transmit very high thrust loads from the engines to the rest of the vehicle (see Figure 1 ). The thrust structure will also be used for primary attachment of the twin vertical tails and possibly act as the aft attach point for the wing. The combination of high loading, high vibration, long service life and high acoustic environments will need to be evaluated by tests. To minimize design risk, a building block approach will be used. We will first screen materials to determine which materials show the most promise for this application. Factors in this screening will be the suitability of these materials for chosen design concepts, particularly concerning specific strength, environmental compatibility and applicability to fabrication processes. Next we will characterize two material systems that will be used in the design; the characterization will allow us to generate preliminary design data that will be used for the analysis. Element testing will be performed to evaluate critical structural locations under load. Final testing on the full scale test article will be performed to verify the design and to demonstrate predictability of the analysis. Additionally, risks associated with fabricating full scale thrust structures will be reduced through testing activities. One of the major concerns that stems from full scale fabrication is the realities of size and the associated complexities of handling, manufacturing, and assembly. The need exists to fabricate, assemble and test_representative joint specimens to achieve_confidence in the design and manufacturing technologies being proposed.
Oberdörster, Günter; Maynard, Andrew; Donaldson, Ken; Castranova, Vincent; Fitzpatrick, Julie; Ausman, Kevin; Carter, Janet; Karn, Barbara; Kreyling, Wolfgang; Lai, David; Olin, Stephen; Monteiro-Riviere, Nancy; Warheit, David; Yang, Hong
2005-01-01
The rapid proliferation of many different engineered nanomaterials (defined as materials designed and produced to have structural features with at least one dimension of 100 nanometers or less) presents a dilemma to regulators regarding hazard identification. The International Life Sciences Institute Research Foundation/Risk Science Institute convened an expert working group to develop a screening strategy for the hazard identification of engineered nanomaterials. The working group report presents the elements of a screening strategy rather than a detailed testing protocol. Based on an evaluation of the limited data currently available, the report presents a broad data gathering strategy applicable to this early stage in the development of a risk assessment process for nanomaterials. Oral, dermal, inhalation, and injection routes of exposure are included recognizing that, depending on use patterns, exposure to nanomaterials may occur by any of these routes. The three key elements of the toxicity screening strategy are: Physicochemical Characteristics, In Vitro Assays (cellular and non-cellular), and In Vivo Assays. There is a strong likelihood that biological activity of nanoparticles will depend on physicochemical parameters not routinely considered in toxicity screening studies. Physicochemical properties that may be important in understanding the toxic effects of test materials include particle size and size distribution, agglomeration state, shape, crystal structure, chemical composition, surface area, surface chemistry, surface charge, and porosity. In vitro techniques allow specific biological and mechanistic pathways to be isolated and tested under controlled conditions, in ways that are not feasible in in vivo tests. Tests are suggested for portal-of-entry toxicity for lungs, skin, and the mucosal membranes, and target organ toxicity for endothelium, blood, spleen, liver, nervous system, heart, and kidney. Non-cellular assessment of nanoparticle durability, protein interactions, complement activation, and pro-oxidant activity is also considered. Tier 1 in vivo assays are proposed for pulmonary, oral, skin and injection exposures, and Tier 2 evaluations for pulmonary exposures are also proposed. Tier 1 evaluations include markers of inflammation, oxidant stress, and cell proliferation in portal-of-entry and selected remote organs and tissues. Tier 2 evaluations for pulmonary exposures could include deposition, translocation, and toxicokinetics and biopersistence studies; effects of multiple exposures; potential effects on the reproductive system, placenta, and fetus; alternative animal models; and mechanistic studies. PMID:16209704
Filtration Effects Due to Bioassay Cage Design and Screen Type
2010-01-01
Optical Nonimaging Light- Scattering Instruments (ASTM, 2003). Droplet sizing data included volume median diam (DV50), and the 10% and 90% diam (DV10 and...optical nonimaging light-scattering instru- ments. In: Annual book of ASTM standards. West Conshohocken, PA: American Society for Testing and Materials
Influence of grid bar shape on field cleaner performance - Screening tests
USDA-ARS?s Scientific Manuscript database
Extractor type cleaners are used on cotton strippers and in the seed cotton cleaning machinery in the ginning process to remove large foreign material such as burrs and sticks. Previous research on the development of extractor type cleaners focused on machine design and operating parameters that max...
Combustion Gas Heating Tests of C/C Composites Coated with SiC Layer
NASA Astrophysics Data System (ADS)
Sato, Masaki; Moriya, Shin-ichi; Sato, Masahiro; Tadano, Makoto; Kusaka, Kazuo; Hasegawa, Keiichi; Kumakawa, Akinaga; Yoshida, Makoto
2008-02-01
In order to examine the applicability of carbon fiber/carbon matrix composites coated with a silicon carbide layer (C/C-SiCs) to an advanced nozzle for the future reusable rocket engines, two series of combustion gas heating tests were conducted using a small rocket combustor. In the first series of heating tests, five different kinds of C/C-SiCs were tested with specimens in the shape of a square plate for material screening. In the second series of heating tests, two selected C/C-SiCs were tested with specimens in the shape of a small nozzle. The effectiveness of an interlayer between a C/C composite and a SiC layer, which was introduced to improve the durability based on the concept of functionally graded materials (FGMs), can be observed. The typical damage mode was also pointed out in the results of heating test using the small nozzle specimens.
Hagemann, G; Eichbaum, G
1997-07-01
The following three film-screen combinations were compared: a) a combination of anticrossover film and UV-light emitting screens, b) a combination of blue-light emitting screens and film, and c) a conventional green fluorescing screen film combination. Radiographs of a specially designed plexiglass phantom (0.2 x 0.2 x 0.12 m3) were obtained that contained bar patterns of lead and plaster (calcium sulfate) to test high and intermediate contrast resolution and bar patterns of air to test low contrast resolution, respectively. An aluminum step wedge was integrated to evaluate dose-density curves of the radiographs. The dose values for the various step thicknesses were measured as percentage of the dose value in air for 60, 81, and 117 kV. Exposure conditions were the following: 12 pulse generator, 0.6 mm focus size, 4.7 mm aluminum prefilter, a grid with 40 lines/cm (12:1), and a focus-detector distance of 1.15 m. The thresholds of visible bars of the various pattern materials were assessed by seven radiologists, one technician, and the authors. The resulting contrast detail diagram could not prove any significant differences between the three tested screen film combinations. The pairwise comparison, however, found 8 of the 18 paired differences to be statistically significant between the conventional and the two new screen-film combinations. The authors concluded that subjective visual assessment of the threshold in a contrast detail study alone is of only limited value to grade image quality if no well-defined criteria are used (BIR report 20 [1989] 137-139). The statistical approach of paired differences of the estimated means appeared to be more appropriate.
Maxwell, Annette E; Danao, Leda L; Cayetano, Reggie T; Crespi, Catherine M; Bastani, Roshan
2016-06-01
The implementation of evidence-based strategies to promote colorectal cancer (CRC) screening remains challenging. The aim of this study is to evaluate two strategies to implement an evidence-based intervention to promote CRC screening in Filipino American community organizations. Twenty-two community organizations were randomized to either a basic or enhanced implementation strategy. In both arms, community health advisors recruited participants non-adherent to CRC screening guidelines, conducted educational sessions, distributed print materials and free fecal occult blood test kits, reminded participants to get screened, and mailed letters to participants' providers. In the enhanced arm, leaders of the organizations participated in implementation efforts. While the effectiveness was similar in both arms of the study (screening rate at 6-month follow-up was 53 % in the enhanced arm, 49 % in the basic arm), 223 participants were screened in the enhanced arm versus 122 in the basic arm. The enhanced implementation strategy reached 83 % more participants and achieved a higher public health impact. NCT01351220 (ClinicalTrials.gov).
Pilot proficiency testing study for second tier congenital adrenal hyperplasia newborn screening.
De Jesús, Víctor R; Simms, David A; Schiffer, Jarad; Kennedy, Meredith; Mei, Joanne V; Hannon, W Harry
2010-11-11
Congenital adrenal hyperplasia (CAH) is caused by inherited defects in steroid biosynthesis. The Newborn Screening Quality Assurance Program (NSQAP) initiated a pilot, dried-blood spot (DBS)-based proficiency testing program designed to investigate materials and laboratory performance for second tier CAH screening by tandem mass spectrometry (MS/MS). The ratio of 17-α-hydroxyprogesterone (17-OHP), androstenedione (4-AD) and cortisol is used as an indicator of CAH in laboratory protocols for second tier analysis of DBS specimens. DBS prepared by NSQAP contained a range of steroid concentrations resulting in different clinical ratios. Laboratories received blind-coded DBS specimens and reported results to NSQAP for evaluation. Quantitative values reported by participants for 17-OHP, 4-AD, and cortisol, reflected small differences in their analytical methods. Average quantitative values for 17-OHP increased from 81% to 107% recovery over the 3.5-year period; cortisol recoveries increased from 61.9% to 89.5%; and 4-AD recoveries decreased from 184% to 68%. Laboratory participation in the CAH second tier proficiency testing program has resulted in improved analyte recoveries and enhanced sample preparation methodologies. NSQAP services for the second tier CAH analysis in DBS demonstrate the need for surveillance to ensure harmonization and continuous improvements, and to achieve sustained high-performance of newborn screening laboratories worldwide. Published by Elsevier B.V.
Santos, Leonilda C.; Vidotto, Odilon; Morikawa, Vivien M.; Santos, Nelson J. R.; Vieira, Thállitha S. W. J.; Barros Filho, Ivan R.; Vieira, Rafael F. C.; Biondo, Alexander W.
2017-01-01
Aim: This study is part of an active surveillance program for monitoring animal health status in endangered species, and was conducted to screen captive Barbary sheep (Ammotragus lervia) for hemoplasma infection. Materials and Methods: A total of 12 blood samples were collected, DNA extracted and further tested by a pan-hemoplasma polymerase chain reaction protocol. Results: Animals were clinically healthy and not infested by ectoparasites. Although housekeeping gene DNA was successfully amplified, all the Barbary sheep samples tested negative for Mycoplasma sp. Conclusion: Notwithstanding the negative results, molecular pathogen surveys on Barbary sheep and other exotic wild mammals may provide insights regarding infection of endangered species caused by captivity stress in association with exposure to new pathogens worldwide. PMID:28919684
Test-Retest Reliability of a Serious Game for Delirium Screening in the Emergency Department
Tong, Tiffany; Chignell, Mark; Tierney, Mary C.; Lee, Jacques S.
2016-01-01
Introduction: Cognitive screening in settings such as emergency departments (ED) is frequently carried out using paper-and-pencil tests that require administration by trained staff. These assessments often compete with other clinical duties and thus may not be routinely administered in these busy settings. Literature has shown that the presence of cognitive impairments such as dementia and delirium are often missed in older ED patients. Failure to recognize delirium can have devastating consequences including increased mortality (Kakuma et al., 2003). Given the demands on emergency staff, an automated cognitive test to screen for delirium onset could be a valuable tool to support delirium prevention and management. In earlier research we examined the concurrent validity of a serious game, and carried out an initial assessment of its potential as a delirium screening tool (Tong et al., 2016). In this paper, we examine the test-retest reliability of the game, as it is an important criterion in a cognitive test for detecting risk of delirium onset. Objective: To demonstrate the test-retest reliability of the screening tool over time in a clinical sample of older emergency patients. A secondary objective is to assess whether there are practice effects that might make game performance unstable over repeated presentations. Materials and Methods: Adults over the age of 70 were recruited from a hospital ED. Each patient played our serious game in an initial session soon after they arrived in the ED, and in follow up sessions conducted at 8-h intervals (for each participant there were up to five follow up sessions, depending on how long the person stayed in the ED). Results: A total of 114 adults (61 females, 53 males) between the ages of 70 and 104 years (M = 81 years, SD = 7) participated in our study after screening out delirious patients. We observed a test-retest reliability of the serious game (as assessed by correlation r-values) between 0.5 and 0.8 across adjacent sessions. Conclusion: The game-based assessment for cognitive screening has relatively strong test-retest reliability and little evidence of practice effects among elderly emergency patients, and may be a useful supplement to existing cognitive assessment methods. PMID:27872590
de Almeida, Sérgio Monteiro; Kamat, Rujvi; Cherner, Mariana; Umlauf, Anya; Ribeiro, Clea E; de Pereira, Ana Paula; Franklin, Donald; Heaton, Robert K; Ellis, Ronald J
2017-03-01
The International HIV Dementia Scale (IHDS) was developed to screen for HIV-associated dementia, but it has been used more generally for HIV-associated neurocognitive disorder (HAND). This study sought to examine the accuracy of the IHDS in a cohort of Brazilian HIV-infected individuals and compare its performance to an alternative screening battery for detecting HAND. A total of 108 participants (including 60 HIV-infected persons) completed the IHDS and a gold standard neuropsychological (NP) battery of 17 tests. As alternative screening method, all possible 3-test combinations from the NP battery were examined and a superiority index (a marker of specificity and sensitivity) was calculated. Sensitivity and specificity to HAND using the standard IHDS cutpoint of 10 were 36% and 75%, respectively. The best balance between sensitivity and specificity was accomplished with a modified cutpoint of 11.5, which yielded sensitivity of 72% and specificity of 58%. The top two most sensitive test combinations, compared with the gold standard NP battery, were Trail Making Test A, Wechsler Adult Intelligence Scale III Digit Symbol and Hopkins Verbal Learning Test-Revised Total Recall (sensitivity 91%, specificity 96%), and Digit Symbol, Brief Visuospatial Memory Test-Revised Total Recall and Grooved Pegboard Test-dominant hand (sensitivity 94%, specificity 91%). Both test combinations can be administered in less than 10 minutes and were more accurate than the IHDS in classifying HIV+ participants as NP impaired or unimpaired. These data suggest that demographically corrected T-scores from commonly used NP measures with modest time and material demands can improve identification of patients with HAND who may benefit from a more extensive NP examination.
Gooding, Holly C; Cheever, Elizabeth; Forman, Sara F; Hatoun, Jonathan; Jooma, Farah; Touloumtzis, Currie; Vernacchio, Louis
2017-05-01
Routine screening for disordered eating or body image concerns is recommended by the American Academy of Pediatrics. We evaluated the ability of two educational interventions to increase screening for eating disorders in pediatric primary care practice, predicting that the "active-learning" group would have an increase in documented screening after intervention. We studied 303 practitioners in a large independent practice association located in the northeastern United States. We used a quasi-experimental design to test the effect of printed educational materials ("print-learning" group, n = 280 participants) compared with in-person shared learning followed by on-line spaced education ("active-learning" group, n = 23 participants) on documented screening of adolescents for eating disorder symptoms during preventive care visits. A subset of 88 participants completed additional surveys regarding knowledge of eating disorders, comfort screening for, diagnosing, and treating eating disorders, and satisfaction with their training regarding eating disorders. During the preintervention period, 4.5% of patients seen by practitioners in both the print-learning and active-learning groups had chart documentation of screening for eating disorder symptoms or body image concerns. This increased to 22% in the active-learning group and 5.7% in the print-learning group in the postintervention period, a statistically significant result. Compared with print-learning participants, active-learning group participants had greater eating disorder knowledge scores, increases in comfort diagnosing eating disorders, and satisfaction with their training in this area. In-person shared learning followed by on-line spaced education is more effective than print educational materials for increasing provider documentation of screening for eating disorders in primary care. Copyright © 2016 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.
Small-scale dynamic confinement gap test
NASA Astrophysics Data System (ADS)
Cook, Malcolm
2011-06-01
Gap tests are routinely used to ascertain the shock sensitiveness of new explosive formulations. The tests are popular since that are easy and relatively cheap to perform. However, with modern insensitive formulations with big critical diameters, large test samples are required. This can make testing and screening of new formulations expensive since large quantities of test material are required. Thus a new test that uses significantly smaller sample quantities would be very beneficial. In this paper we describe a new small-scale test that has been designed using our CHARM ignition and growth routine in the DYNA2D hydrocode. The new test is a modified gap test and uses detonating nitromethane to provide dynamic confinement (instead of a thick metal case) whilst exposing the sample to a long duration shock wave. The long duration shock wave allows less reactive materials that are below their critical diameter, more time to react. We present details on the modelling of the test together with some preliminary experiments to demonstrate the potential of the new test method.
Calzada-Contreras, Adriana; Moreno-Hernández, Manuel; Castillo-Torres, Noemi Patricia; Souto-Rosillo, Guadalupe; Hernández-Juárez, Jesús; Ricardo-Moreno, María Tania; Sánchez-Fernández, Maria Guadalupe de Jesús; García-González, América; Majluf-Cruz, Abraham
2012-01-01
The blood coagulation system maintains the blood in a liquid state and bleeding and thrombosis are the manifestations of its malfunction. Blood coagulation laboratory evaluates the physiology of this system. To establish both, the reference values for several tests performed at the blood coagulation laboratory as well as the utility of the pooled plasma to perform these assays. MATERIAL AND: In this descriptive, cross-sectional, randomized study, we collected plasma from Mexican Mestizos. Each pooled plasma was prepared with the plasma from at least 20 blood donors. We performed screening and special tests and the Levey-Jennings graphs were built and interpreted after each pass. Results of the tests were analyzed and their distribution was established using the Kolmogorov-Smirnov test. To establish the reference values we used 95% confidence intervals. We collected 72 pooled plasmas. The distribution for PT, APTT, and TT tests was abnormal. Although the PT test showed a bimodal distribution it was normal for factor VII. The reference values for the hemostatic, anticoagulant, and fibrinolytic factors were different from those suggested by the manufacturers. We established the reference values for the blood coagulation tests in the adult Mexican population. We have shown that the pooled plasma must be used for the screening tests. We suggest that each clinical laboratory should establish its own reference values (at least for the screening tests). To reach this objective, we encourage the use of the pooled plasma.
Testing of household products and materials for emission of toluene diisocyanate.
Kelly, T J; Myers, J D; Holdren, M W
1999-06-01
Polyurethane products were subjected to chamber testing to determine their emission rates of 2,4- and 2,6-toluene diisocyanate (TDI). The polyurethane (PU) products included carpet padding, furniture cushions, sheet foam, varnishes, and sealants, as well as a commercially-applied water sealant product for concrete that contained up to 4 percent TDI by weight. The PU products were screened in a 9-L glass chamber, under elevated temperature and chamber loading conditions, using both a time-integrated sampling and analysis method specific for TDI and a continuous but non-specific real-time monitor for isocyanates. None of the products normally found in residences showed a positive response in the screening tests, indicating that TDI emissions and consequently toxic effects from such products are negligible. However, the commercially-applied water sealant gave a positive response in the screening test. Further testing of that product at realistic temperatures showed initial TDI emission rates of about 300,000 micrograms/m2/hr, with emissions lasting only one hour or less. At 21 and 27 degrees C, about 1 percent and 5 percent, respectively, of the TDI content of the product was released to the air. The emitted TDI was predominantly the 2,6-isomer, although the TDI originally present in the product was predominantly the 2,4-isomer.
Development of heat-storage building materials for passive-solar applications
NASA Astrophysics Data System (ADS)
Fletcher, J. W.
A heat storage building material to be used for passive solar applications and general load leveling within building spaces was developed. Specifically, PCM-filled plastic panels are to be developed as wallboard and ceiling panels. Three PCMs (CaCl2, 6H2O; Na2SO4, 10H2O; LiNO3, 3H2O are to be evaluated for use in the double walled, hollow channeled plastic panels. Laboratory development of the panels will include determination of filling and sealing techniques, behavior of the PCMs, container properties and materials compatibility. Testing will include vapor transmission, thermal cycle, dynamic performance, accelerated life and durability tests. In addition to development and testing, an applications analysis will be performed for specific passive solar applications. Conceptual design of a single family passive solar residence will be prepared and performance evaluated. Screening of the three PCM candidates is essentially complete.
Christy, Shannon M; Davis, Stacy N; Williams, Kimberly R; Zhao, Xiuhua; Govindaraju, Swapomthi K; Quinn, Gwendolyn P; Vadaparampil, Susan T; Lin, Hui-Yi; Sutton, Steven K; Roethzeim, Richard R; Shibata, David; Meade, Cathy D; Gwede, Clement K
2016-11-15
Intervention studies among individuals in diverse community settings are needed to reduce health disparities in colorectal cancer (CRC) screening and mortality rates. The current study compared the efficacy of 2 intervention conditions promoting CRC screening among black individuals. Black individuals ages 50 to 75 years (N = 330) were recruited in community settings in 4 Tampa Bay counties. After obtaining consent and conducting a baseline interview to assess sociodemographic and health-related variables, participants received either a culturally targeted CRC photonovella booklet plus a fecal immunochemical test (FIT) kit or a standard CRC screening brochure plus an FIT kit. The primary outcome was FIT kit screening uptake. FIT screening uptake at 6 months was 86.7% overall (90.3% in the brochure group and 81.9% in the photonovella group). Controlling for baseline between-group differences, there was no influence of intervention on FIT kit uptake (P = .756). Significant predictors of not returning an FIT kit included being unable to work (P = .010), having higher religious belief scores (P = .015), and living farther from the cancer center (P = .015). Providing FIT kits and educational print materials to black individuals in community settings resulted in high rates of CRC screening. The study also identified subgroups of participants who were less likely to return an FIT kit and provides insight for future interventions. Cancer 2016;122:3288-3296. © 2016 American Cancer Society. © 2016 American Cancer Society.
Non-Nuclear Testing of Fission Technologies at NASA MSFC
NASA Technical Reports Server (NTRS)
Houts, Robert G.; Pearson, J. Boise; Aschenbrenner, Kenneth C.; Bradley, David E.; Dickens, Ricky E.; Emrich, William J.; Garber, Anne E.; Godfroy, Thomas J.; Harper, Roger T.; Martin, Jim J.;
2011-01-01
Highly realistic non-nuclear testing can be used to investigate and resolve potential issues with space nuclear power and propulsion systems. Non-nuclear testing is particularly useful for systems designed with fuels and materials operating within their demonstrated nuclear performance envelope. Non-nuclear testing also provides an excellent way for screening potential advanced fuels and materials prior to nuclear testing, and for investigating innovative geometries and operating regimes. Non-nuclear testing allows thermal hydraulic, heat transfer, structural, integration, safety, operational, performance, and other potential issues to be investigated and resolved with a greater degree of flexibility and at reduced cost and schedule compared to nuclear testing. The primary limit of non-nuclear testing is that nuclear characteristics and potential nuclear issues cannot be directly investigated. However, non-nuclear testing can be used to augment the potential benefit from any nuclear testing that may be required for space nuclear system design and development. This paper describes previous and ongoing non-nuclear testing related to space nuclear systems at NASA s Marshall Space Flight Center (MSFC).
Screening hybridomas for anabolic androgenic steroids by steroid analog antigen microarray.
Du, Hongwu; Chen, Guangyu; Bian, Yongzhong; Xing, Cenzan; Ding, Xue; Zhu, Mengliang; Xun, Yiping; Chen, Peng; Zhou, Yabin; Li, Shaoxu
2015-01-01
Currently, dozens of anabolic androgenic steroids (AAS) are forbidden in the World Anti-Doping Agency Prohibited List, however, despite extensive investigation, there are still lots of AAS without corresponding monoclonal antibodies. A steroid analog antigen microarray made up of ten AAS was fabricated to screen the hybridoma and it was found an original unsuccessful clone turned out to be a candidate anti-boldenone antibody, without any cross-reactions with endogenous AAS or 44 different AAS standard reference materials tested. Our findings suggested that steroid analog antigen microarray could be a promising tool to screen and characterize new applications of antibodies for structure analogs, and this also exhibits the potential to fast identify effective epitopes of hybridomas in a single assay.
NASA Astrophysics Data System (ADS)
Zimmermann, Nils E. R.; Horton, Matthew K.; Jain, Anubhav; Haranczyk, Maciej
2017-11-01
Structure-property relationships form the basis of many design rules in materials science, including synthesizability and long-term stability of catalysts, control of electrical and optoelectronic behavior in semiconductors as well as the capacity of and transport properties in cathode materials for rechargeable batteries. The immediate atomic environments (i.e., the first coordination shells) of a few atomic sites are often a key factor in achieving a desired property. Some of the most frequently encountered coordination patterns are tetrahedra, octahedra, body and face-centered cubic as well as hexagonal closed packed-like environments. Here, we showcase the usefulness of local order parameters to identify these basic structural motifs in inorganic solid materials by developing classification criteria. We introduce a systematic testing framework, the Einstein crystal test rig, that probes the response of order parameters to distortions in perfect motifs to validate our approach. Subsequently, we highlight three important application cases. First, we map basic crystal structure information of a large materials database in an intuitive manner by screening the Materials Project (MP) database (61,422 compounds) for element-specific motif distributions. Second, we use the structure-motif recognition capabilities to automatically find interstitials in metals, semiconductor, and insulator materials. Our Interstitialcy Finding Tool (InFiT) facilitates high-throughput screenings of defect properties. Third, the order parameters are reliable and compact quantitative structure descriptors for characterizing diffusion hops of intercalants as our example of magnesium in MnO2-spinel indicates. Finally, the tools developed in our work are readily and freely available as software implementations in the pymatgen library, and we expect them to be further applied to machine-learning approaches for emerging applications in materials science.
Zimmermann, Nils E. R.; Horton, Matthew K.; Jain, Anubhav; ...
2017-11-13
Structure–property relationships form the basis of many design rules in materials science, including synthesizability and long-term stability of catalysts, control of electrical and optoelectronic behavior in semiconductors, as well as the capacity of and transport properties in cathode materials for rechargeable batteries. The immediate atomic environments (i.e., the first coordination shells) of a few atomic sites are often a key factor in achieving a desired property. Some of the most frequently encountered coordination patterns are tetrahedra, octahedra, body and face-centered cubic as well as hexagonal close packed-like environments. Here, we showcase the usefulness of local order parameters to identify thesemore » basic structural motifs in inorganic solid materials by developing classification criteria. We introduce a systematic testing framework, the Einstein crystal test rig, that probes the response of order parameters to distortions in perfect motifs to validate our approach. Subsequently, we highlight three important application cases. First, we map basic crystal structure information of a large materials database in an intuitive manner by screening the Materials Project (MP) database (61,422 compounds) for element-specific motif distributions. Second, we use the structure-motif recognition capabilities to automatically find interstitials in metals, semiconductor, and insulator materials. Our Interstitialcy Finding Tool (InFiT) facilitates high-throughput screenings of defect properties. Third, the order parameters are reliable and compact quantitative structure descriptors for characterizing diffusion hops of intercalants as our example of magnesium in MnO 2-spinel indicates. Finally, the tools developed in our work are readily and freely available as software implementations in the pymatgen library, and we expect them to be further applied to machine-learning approaches for emerging applications in materials science.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zimmermann, Nils E. R.; Horton, Matthew K.; Jain, Anubhav
Structure–property relationships form the basis of many design rules in materials science, including synthesizability and long-term stability of catalysts, control of electrical and optoelectronic behavior in semiconductors, as well as the capacity of and transport properties in cathode materials for rechargeable batteries. The immediate atomic environments (i.e., the first coordination shells) of a few atomic sites are often a key factor in achieving a desired property. Some of the most frequently encountered coordination patterns are tetrahedra, octahedra, body and face-centered cubic as well as hexagonal close packed-like environments. Here, we showcase the usefulness of local order parameters to identify thesemore » basic structural motifs in inorganic solid materials by developing classification criteria. We introduce a systematic testing framework, the Einstein crystal test rig, that probes the response of order parameters to distortions in perfect motifs to validate our approach. Subsequently, we highlight three important application cases. First, we map basic crystal structure information of a large materials database in an intuitive manner by screening the Materials Project (MP) database (61,422 compounds) for element-specific motif distributions. Second, we use the structure-motif recognition capabilities to automatically find interstitials in metals, semiconductor, and insulator materials. Our Interstitialcy Finding Tool (InFiT) facilitates high-throughput screenings of defect properties. Third, the order parameters are reliable and compact quantitative structure descriptors for characterizing diffusion hops of intercalants as our example of magnesium in MnO 2-spinel indicates. Finally, the tools developed in our work are readily and freely available as software implementations in the pymatgen library, and we expect them to be further applied to machine-learning approaches for emerging applications in materials science.« less
In-situ upgrading of biomass pyrolysis vapors: catalyst screening on a fixed bed reactor.
Stefanidis, S D; Kalogiannis, K G; Iliopoulou, E F; Lappas, A A; Pilavachi, P A
2011-09-01
In-situ catalytic upgrading of biomass fast pyrolysis vapors was performed in a fixed bed bench-scale reactor at 500°C, for catalyst screening purposes. The catalytic materials tested include a commercial equilibrium FCC catalyst (E-cat), various commercial ZSM-5 formulations, magnesium oxide and alumina materials with varying specific surface areas, nickel monoxide, zirconia/titania, tetragonal zirconia, titania and silica alumina. The bio-oil was characterized measuring its water content, the carbon-hydrogen-oxygen (by difference) content and the chemical composition of its organic fraction. Each catalytic material displayed different catalytic effects. High surface area alumina catalysts displayed the highest selectivity towards hydrocarbons, yielding however low organic liquid products. Zirconia/titania exhibited good selectivity towards desired compounds, yielding higher organic liquid product than the alumina catalysts. The ZSM-5 formulation with the highest surface area displayed the most balanced performance having a moderate selectivity towards hydrocarbons, reducing undesirable compounds and producing organic liquid products at acceptable yields. Copyright © 2011 Elsevier Ltd. All rights reserved.
Characterization of polymer silver pastes for screen printed flexible RFID antennas
NASA Astrophysics Data System (ADS)
Janeczek, Kamil; Jakubowska, Małgorzata; Futera, Konrad; MłoŻniak, Anna; Kozioł, GraŻyna; Araźna, Aneta
Radio Frequency Identification (RFID) systems have become more and more popular in the last few years because of their wide application fields, such as supply chain management and logistics. To continue their development further investigations of new conductive materials for fabrication of RFID transponders' antennas are necessary to be carried out. These materials should provide high flexibility and good radiation performance of printed antennas. In this paper, two polymer silver pastes based on silver flakes were characterized with regard to manufacturing of flexible RFID antennas with screen printing technique. Foil and paper were used as a substrate materials. Surface profile of the printed antennas was measured using an optical profilometer and their resistance was measured with a four-point-probe method. Antenna flexibility was evaluated in cyclic bending tests and its performance with reflection coefficient measurements with the use of differential probe connected to a vector network analyzer. In addition, a maximum read distance of a fabricated RFID transponder was measured.
Eugster, Albert; Murmann, Petra; Kaenzig, Andre; Breitenmoser, Alda
2014-10-01
In routine analysis screening methods based on real-time PCR (polymerase chain reaction) are most commonly used for the detection of genetically modified (GM) plant material in food and feed. Screening tests are based on sequences frequently used for GM development, allowing the detection of a large number of GMOs (genetically modified organisms). Here, we describe the development and validation of a tetraplex real-time PCR screening assay comprising detection systems for the regulatory genes Cauliflower Mosaic Virus 35S promoter, Agrobacterium tumefaciens nos terminator, Cauliflower Mosaic Virus 35S terminator and Figwort Mosaic Virus 34S promoter. Three of the four primer and probe combinations have already been published elsewhere, whereas primers and probe for the 35S terminator have been developed in-house. Adjustment of primer and probe concentrations revealed a high PCR sensitivity with insignificant physical cross-talk between the four detection channels. The sensitivity of each PCR-system is sufficient to detect a GMO concentration as low as 0.05% of the containing respective element. The specificity of the described tetraplex is high when tested on DNA from GM maize, soy, rapeseed and tomato. We also demonstrate the robustness of the system by inter-laboratory tests. In conclusion, this method provides a sensitive and reliable screening procedure for the detection of the most frequently used regulatory elements present in GM crops either authorised or unauthorised for food.
Fernandez, Michael; Boyd, Peter G; Daff, Thomas D; Aghaji, Mohammad Zein; Woo, Tom K
2014-09-04
In this work, we have developed quantitative structure-property relationship (QSPR) models using advanced machine learning algorithms that can rapidly and accurately recognize high-performing metal organic framework (MOF) materials for CO2 capture. More specifically, QSPR classifiers have been developed that can, in a fraction of a section, identify candidate MOFs with enhanced CO2 adsorption capacity (>1 mmol/g at 0.15 bar and >4 mmol/g at 1 bar). The models were tested on a large set of 292 050 MOFs that were not part of the training set. The QSPR classifier could recover 945 of the top 1000 MOFs in the test set while flagging only 10% of the whole library for compute intensive screening. Thus, using the machine learning classifiers as part of a high-throughput screening protocol would result in an order of magnitude reduction in compute time and allow intractably large structure libraries and search spaces to be screened.
Turkec, Aydin; Kazan, Hande; Karacanli, Burçin; Lucas, Stuart J
2015-08-01
In this paper, DNA extraction methods have been evaluated to detect the presence of genetically modified organisms (GMOs) in maize food and feed products commercialised in Turkey. All the extraction methods tested performed well for the majority of maize foods and feed products analysed. However, the highest DNA content was achieved by the Wizard, Genespin or the CTAB method, all of which produced optimal DNA yield and purity for different maize food and feed products. The samples were then screened for the presence of GM elements, along with certified reference materials. Of the food and feed samples, 8 % tested positive for the presence of one GM element (NOS terminator), of which half (4 % of the total) also contained a second element (the Cauliflower Mosaic Virus 35S promoter). The results obtained herein clearly demonstrate the presence of GM maize in the Turkish market, and that the Foodproof GMO Screening Kit provides reliable screening of maize food and feed products.
A graphite-lined regeneratively cooled thrust chamber
NASA Technical Reports Server (NTRS)
Stubbs, V. R.
1972-01-01
Design concepts, based on use of graphite as a thermal barrier for regeneratively cooled FLOX-methane thrust chambers, have been screened and concepts selected for detailed thermodynamic, stress, and fabrication analyses. A single design employing AGCarb-101, a fibrous graphite composite material, for a thermal barrier liner and an electroformed nickel structure with integral coolant passages was selected for fabrication and testing. The fabrication processes and the test results are described and illustrated.
NASA Technical Reports Server (NTRS)
Hickman, Robert; Broadway, Jeramie
2014-01-01
CERMET fuel materials are being developed at the NASA Marshall Space Flight Center for a Nuclear Cryogenic Propulsion Stage. Recent work has resulted in the development and demonstration of a Compact Fuel Element Environmental Test (CFEET) System that is capable of subjecting depleted uranium fuel material samples to hot hydrogen. A critical obstacle to the development of an NCPS engine is the high-cost and safety concerns associated with developmental testing in nuclear environments. The purpose of this testing capability is to enable low-cost screening of candidate materials, fabrication processes, and further validation of concepts. The CERMET samples consist of depleted uranium dioxide (UO2) fuel particles in a tungsten metal matrix, which has been demonstrated on previous programs to provide improved performance and retention of fission products1. Numerous past programs have utilized hot hydrogen furnace testing to develop and evaluate fuel materials. The testing provides a reasonable simulation of temperature and thermal stress effects in a flowing hydrogen environment. Though no information is gained about radiation damage, the furnace testing is extremely valuable for development and verification of fuel element materials and processes. The current work includes testing of subscale W-UO2 slugs to evaluate fuel loss and stability. The materials are then fabricated into samples with seven cooling channels to test a more representative section of a fuel element. Several iterations of testing are being performed to evaluate fuel mass loss impacts from density, microstructure, fuel particle size and shape, chemistry, claddings, particle coatings, and stabilizers. The fuel materials and forms being evaluated on this effort have all been demonstrated to control fuel migration and loss. The objective is to verify performance improvements of the various materials and process options prior to expensive full scale fabrication and testing. Post test analysis will include weight percent fuel loss, microscopy, dimensional tolerance, and fuel stability.
Turkec, Aydin; Kazan, Hande; Baykut, Aykut; Lucas, Stuart J
2015-01-01
Soybean is one of the most important biotech crops, widely used as an ingredient in both foodstuffs and feed. DNA extraction methods have been evaluated to detect the presence of genetically modified (GM) materials in soya-containing food and feed products commercialised in Turkey. All extraction methods performed well for the majority of soya foods and feed products analysed. However, the most successful method varied between different products; the Foodproof, Genespin and the cetyltrimethylammonium bromide (CTAB) methods each produced the highest DNA yield and purity for different soya foodstuffs and feeds. Of the samples tested, 20% were positive for the presence of at least two GM elements (35S/NOS) while 11% contained an additional GM element (35S/NOS/FMV). Of the tested products, animal feeds showed a larger prevalence of GM material (50%) than the soya-containing foodstuffs (13%). The best performing extraction methods proved to be the Foodproof, Genespin and CTAB methods for soya-containing food and feed products. The results obtained herein clearly demonstrate the presence of GM soybean in the Turkish market, and that the Foodproof GMO Screening Kit provides reliable screening of soy-containing food and feed products. © 2014 Society of Chemical Industry.
Preliminary study on antifungal effect of commercial essential oils against white rot fungi
NASA Astrophysics Data System (ADS)
Khalid, Nurul Izzaty; Baharum, Azizah; Daud, Fauzi
2015-09-01
Protecting and preserving wood plastic composite from deterioration caused by fungal attack is a high challenge issue to cater nowadays. The objective of this study was to carry out a screening test towards antifungal effect of essential oil and to investigate the potential of raw materials that will be used as basic material for manufacturing wood plastic composite against white rot fungi. Essential oils from four types of natural products comprising cinnamon, lemongrass, lavender and geranium have been screened for their ability to inhibit five types of white rot fungi species which are Lentinus squarrosulus, Pleuorotus pulmonarius, Lentinus sp., Pleuorotus sajor-caju and Lignosus rhinocerus. The antifungal evaluation showed that no inhibitory effect against tested white rot fungi since the mycelia completely filled the plates. From the observation, mycelia of L. squarrosulus, P. pulmonarius and Lentinus sp. were found to filled the surface of falcon tubes with rubber sawdust after 15 days. Mycelia of L. squarrosulus and P. pulmonarius also were found to completely covered the surface of media that contain polypropylene and maleic anhydride grafted polypropylene on it. Therefore, this report proved that the main materials that will be applicable in manufacturing of wood plastic composite had potential to be degraded by this type of fungal attack.
2011-12-30
The Food and Drug Administration (FDA) is amending the regulation classifying ovarian adnexal mass assessment score test systems to restrict these devices so that a prescribed warning statement that addresses a risk identified in the special controls guidance document must be in a black box and must appear in all labeling, advertising, and promotional material. The black box warning mitigates the risk to health associated with off-label use as a screening test, stand-alone diagnostic test, or as a test to determine whether or not to proceed with surgery.
Nanomaterials are a diverse collection of novel materials that exhibit at least one dimension less than 100 nm and display unique chemical and physical properties due to their nanoscale size. An emphasis has been put on developing high throughput screening (HTS) assays to charac...
Fast Neutron Tomography of Low-Z Object in High-Z Material Shielding
NASA Astrophysics Data System (ADS)
Babai, Ruth Weiss; Sabo-Napadensky, Iris; Bar, Doron; Mor, Ilan; Tamim, Noam; Dangendorf, Volker; Tittelmeier, Kai; Bromberger, Benjamin; Weierganz, Mathias
The technique and first results of Fast Neutron Tomography (FNCT) experiments are presented which are performed at the accelerator facility of PTB, Germany. A high-intensity neutron beam of broad spectral distribution with an average energy of 5.5 MeV, was produced by 11.5 MeV deuterons impinging upon a thick beryllium target. The capability of FNCT for high contrast imaging of low-Z materials embedded in thick high-Z shielding materials is demonstrated, which is superior to more conventional high-energy X-ray imaging techniques. For demonstrating the method special test objects were prepared: One consisted of an assembled polyethylene cylinder with holes of various diameters and directions drilled in its surface and inner parts. The plastic phantom was inserted into lead cylinders of different thicknesses. The detector system consisted of a plastic scintillator along with a dedicated optics, image-intensifier and a CCD camera. Two scintillator screens were compared: a bulk plastic scintillator screen and a fibres optical scintillator screen. The tomographic scans were taken in two geometrical configurations: cone beam and semi-fan beam configuration. The image quality favours the semi-fan beam configuration which on the other hand is more time consuming The obtained tomographic images and a comparison of the imaging quality between the different experimental conditions will be presented.
NASA Technical Reports Server (NTRS)
1973-01-01
The ALERT program, a system for communicating common problems with parts, materials, and processes, is condensed and catalogued. Expanded information on selected topics is provided by relating the problem area (failure) to the cause, the investigations and findings, the suggestions for avoidance (inspections, screening tests, proper part applications), and failure analysis procedures. The basic objective of ALERT is the avoidance of the recurrence of parts, materials, and processed problems, thus improving the reliability of equipment produced for and used by the government.
Staniszewska, Marta; Boniecka, Helena
2018-05-01
It has been shown that the current approach to the assessment of contamination in the sediments obtained during the dredging works in the Baltic countries indicates the presence of "non-contaminated" dredged material. The concentration limits of heavy metals, Polycyclic Aromatic Hydrocarbons (PAHs), Polychlorinated Biphenyls (PCBs) have been exceeded only in 1% of the samples obtained during the dredging works (2005-2015) within the Polish coastal zone. After 2008, no contaminated sediments have been found. Also, in the remaining Baltic countries, sediments are very rarely contaminated. As a result of this assessment, the sediments can be stored in the sea or have a practical application. However, it has been questioned whether the large cost of determining the numerous chemical parameters is justified. It has been proposed to carry out simple screening tests. Following the preliminary screening, the decision on more detailed (and expensive) chemical tests of individual pollutants would be made. Copyright © 2018 Elsevier Ltd. All rights reserved.
Bae, Jong-Myon; Shin, Sang Yop; Kim, Eun Hee
2015-01-01
Purpose This retrospective cohort study was conducted to estimate the optimal interval for gastric cancer screening in Korean adults with initial negative screening results. Materials and Methods This study consisted of voluntary Korean screenees aged 40 to 69 years who underwent subsequent screening gastroscopies after testing negative in the baseline screening performed between January 2007 and December 2011. A new case was defined as the presence of gastric cancer cells in biopsy specimens obtained upon gastroscopy. The follow-up periods were calculated during the months between the date of baseline screening gastroscopy and positive findings upon subsequent screenings, stratified by sex and age group. The mean sojourn time (MST) for determining the screening interval was estimated using the prevalence/incidence ratio. Results Of the 293,520 voluntary screenees for the gastric cancer screening program, 91,850 (31.29%) underwent subsequent screening gastroscopies between January 2007 and December 2011. The MSTs in men and women were 21.67 months (95% confidence intervals [CI], 17.64 to 26.88 months) and 15.14 months (95% CI, 9.44 to 25.85 months), respectively. Conclusion These findings suggest that the optimal interval for subsequent gastric screening in both men and women is 24 months, supporting the 2-year interval recommended by the nationwide gastric cancer screening program. PMID:25687874
Research on automatic Hartmann test of membrane mirror
NASA Astrophysics Data System (ADS)
Zhong, Xing; Jin, Guang; Liu, Chunyu; Zhang, Peng
2010-10-01
Electrostatic membrane mirror is ultra-lightweight and easy to acquire a large diameter comparing with traditional optical elements, so its development and usage is the trend of future large mirrors. In order to research the control method of the static stretching membrane mirror, the surface configuration must be tested. However, membrane mirror's shape is always changed by variable voltages on the electrodes, and the optical properties of membrane materials using in our experiment are poor, so it is difficult to test membrane mirror by interferometer and null compensator method. To solve this problem, an automatic optical test procedure for membrane mirror is designed based on Hartmann screen method. The optical path includes point light source, CCD camera, splitter and diffuse transmittance screen. The spots' positions on the diffuse transmittance screen are pictured by CCD camera connected with computer, and image segmentation and centroid solving is auto processed. The CCD camera's lens distortion is measured, and fixing coefficients are given to eliminate the spots' positions recording error caused by lens distortion. To process the low sampling Hartmann test results, Zernike polynomial fitting method is applied to smooth the wave front. So low frequency error of the membrane mirror can be measured then. Errors affecting the test accuracy are also analyzed in this paper. The method proposed in this paper provides a reference for surface shape detection in membrane mirror research.
Dubourg, Georges; Segkos, Apostolos; Katona, Jaroslav; Radović, Marko; Savić, Slavica; Crnojević-Bengin, Vesna
2017-01-01
This paper describes the fabrication and the characterization of an original example of a miniaturized resistive-type humidity sensor, printed on flexible substrate in a large-scale manner. The fabrication process involves laser ablation for the design of interdigitated electrodes on PET (Poly-Ethylene Terephthalate) substrate and a screen-printing process for the deposition of the sensitive material, which is based on TiO2 nanoparticles. The laser ablation process was carefully optimized to obtain micro-scale and well-resolved electrodes on PET substrate. A functional paste based on cellulose was prepared in order to allow the precise screen-printing of the TiO2 nanoparticles as sensing material on the top of the electrodes. The current against voltage (I–V) characteristic of the sensor showed good linearity and potential for low-power operation. The results of a humidity-sensing investigation and mechanical testing showed that the fabricated miniaturized sensors have excellent mechanical stability, sensing characteristics, good repeatability, and relatively fast response/recovery times operating at room temperature. PMID:28800063
Wieland, Daryl L.; Reimers, Laura L.; Wu, Eijean; Nathan, Lisa M.; Gruenberg, Tammy; Abadi, Maria; Einstein, Mark H.
2013-01-01
Objective In 2006, the American Society for Colposcopy and Cervical Pathology (ASCCP) updated evidence based guidelines recommending screening intervals for women with abnormal cervical cytology. In our low-income inner city population, we sought to improve performance by uniformly applying the guidelines to all patients. We report the prospective performance of a comprehensive tracking, evidence-based algorithmically driven call-back and appointment scheduling system for cervical cancer screening in a resource-limited inner city population. Materials and Methods Outreach efforts were formalized with algorithm-based protocols for triage to colposcopy, with universal adherence to evidence-based guidelines. During implementation from August 2006 through July 2008, we prospectively tracked performance using the electronic medical record with administrative and pathology reports to determine performance variables such as the total number of Pap tests, colposcopy visits, and the distribution of abnormal cytology and histology results, including all CIN 2,3 diagnoses. Results 86,257 gynecologic visits and 41,527 Pap tests were performed system-wide during this period of widespread and uniform implementation of standard cervical cancer screening guidelines. The number of Pap tests performed per month varied little. The incidence of CIN 1 significantly decreased from 117/171 (68.4%) the first tracked month to 52/95 (54.7%) the last tracked month (p=0.04). The monthly incidence rate of CIN 2,3, including incident cervical cancers did not change. The total number of colposcopy visits declined, resulting in a 50% decrease in costs related to colposcopy services and approximately a 12% decrease in costs related to excisional biopsies. Conclusions Adherence to cervical cancer screening guidelines reduced the number of unnecessary colposcopies without increasing numbers of potentially missed CIN 2,3 lesions, including cervical cancer. Uniform implementation of administrative-based performance initiatives for cervical cancer screening minimizes differences in provider practices and maximizes performance of screening while containing cervical cancer screening costs. PMID:21959573
Liu, Rentao; Jiang, Jiping; Guo, Liang; Shi, Bin; Liu, Jie; Du, Zhaolin; Wang, Peng
2016-06-01
In-depth filtering of emergency disposal technology (EDT) and materials has been required in the process of environmental pollution emergency disposal. However, an urgent problem that must be solved is how to quickly and accurately select the most appropriate materials for treating a pollution event from the existing spill control and clean-up materials (SCCM). To meet this need, the following objectives were addressed in this study. First, the material base and a case base for environment pollution emergency disposal were established to build a foundation and provide material for SCCM screening. Second, the multiple case-based reasoning model method with a difference-driven revision strategy (DDRS-MCBR) was applied to improve the original dual case-based reasoning model method system, and screening and decision-making was performed for SCCM using this model. Third, an actual environmental pollution accident from 2012 was used as a case study to verify the material base, case base, and screening model. The results demonstrated that the DDRS-MCBR method was fast, efficient, and practical. The DDRS-MCBR method changes the passive situation in which the choice of SCCM screening depends only on the subjective experience of the decision maker and offers a new approach to screening SCCM.
Through-barrier detection of explosive components for security screening applications
NASA Astrophysics Data System (ADS)
Lee, Linda; Frisby, Alex; Mansson, Ralph; Hopkins, Rebecca J.
2011-11-01
The detection of materials through containers is a vital capability for security screening applications at high risk locations, such as airports and checkpoints. Current detection procedures require suspect containers to be opened and the contents sampled, which is laborious and potentially hazardous to the operator. The capability to detect through-barrier would overcome these issues. Spatially Offset Raman Spectroscopy (SORS) is an innovative spectroscopic technique that avoids fluorescence and Raman scatter from containers, which can mask the Raman signature from the sample. This novel approach enables noninvasive detection of hazardous and benign materials through a wider range of container materials than is possible using conventional Raman spectroscopy. SORS spectra were acquired from explosive compounds and benign materials within a range of coloured glass and plastic containers. The SORS spectra were compared to the reference Raman signatures of the materials studied. Two data analysis methods were then applied to the resultant data to investigate the ability of SORS to detect the target materials through the barriers tested. Furthermore, the potential for reduction of sample fluorescence was investigated by using longer excitation wavelength (1064 nm) than is typically used in commercially available Raman instruments that use silicon detector technology. For some fluorescent samples, Raman spectral features that were masked by fluorescence at 785 nm were revealed at 1064 nm.
Manufacturing of prestressed piezoelectric unimorphs using a postfired biasing layer.
Juuti, Jari A; Jantunen, Heli; Moilanen, Veli-Pekka; Leppävuori, Seppo
2006-05-01
A novel manufacturing method for prestressed piezoelectric unimorphs is introduced and the actuator properties are examined. Prestressed PZT 5A and PZT 5H unimorphs with piezo material thickness of 250 microm and 375 microm were manufactured by using sintering and thermal shrinkage of the prestressing material. The process was carried out by screen printing a layer of AgPd paste on one side of the sintered bulk ceramic. As an alternative method, dielectric low temperature co-fired ceramic (LTCC) tape was used as the prestressing material. Different configurations were tested to obtain high displacements and to make a comparison between materials. After firing, the samples were poled, and the displacement versus load characteristics of the resulting actuators were investigated. A maximum displacement of 118 microm was obtained from a 250 microm thick, prestressed PZT 5H actuator with a diameter of 25 mm, in which LTCC tape was used as the prestressing layer. Similarly, the PZT 5H material provided a maximum displacement of 63 microm with a screen-printed AgPd prestressing layer. The manufacturing method described offers a novel approach for the production of a wide range of integrated active structures on, for instance, an LTCC circuit board. This is especially important because piezoelectric bulk materials with high piezoelectric coefficients can be used to produce high displacements.
Screen test for cadmium and nickel plates as developed and used within the Aerospace Corporation
NASA Technical Reports Server (NTRS)
Phan, A. H.; Zimmerman, A. H.
1994-01-01
A new procedure described here was recently developed to quantify loading uniformity of nickel and cadmium plates and to screen finished electrodes prior to cell assembly. The technique utilizes the initial solubility rates of the active material in a standard chemical deloading solution at fixed conditions. The method can provide a reproducible indication of plate loading uniformity in situations where high surface loading limits the free flow of deloading solution into the internal porosity of the sinter plate. A preliminary study indicates that 'good' cell performance is associated with higher deloading rates.
Centrifugal Sieve for Gravity-Level-Independent Size Segregation of Granular Materials
NASA Technical Reports Server (NTRS)
Walton, Otis R.; Dreyer, Christopher; Riedel, Edward
2013-01-01
Conventional size segregation or screening in batch mode, using stacked vibrated screens, is often a time-consuming process. Utilization of centrifugal force instead of gravity as the primary body force can significantly shorten the time to segregate feedstock into a set of different-sized fractions. Likewise, under reduced gravity or microgravity, a centrifugal sieve system would function as well as it does terrestrially. When vibratory and mechanical blade sieving screens designed for terrestrial conditions were tested under lunar gravity conditions, they did not function well. The centrifugal sieving design of this technology overcomes the issues that prevented sieves designed for terrestrial conditions from functioning under reduced gravity. These sieves feature a rotating outer (cylindrical or conical) screen wall, rotating fast enough for the centrifugal forces near the wall to hold granular material against the rotating screen. Conventional centrifugal sieves have a stationary screen and rapidly rotating blades that shear the granular solid near the stationary screen, and effect the sieving process assisted by the airflow inside the unit. The centrifugal sieves of this new design may (or may not) have an inner blade or blades, moving relative to the rotating wall screen. Some continuous flow embodiments would have no inner auger or blades, but achieve axial motion through vibration. In all cases, the shearing action is gentler than conventional centrifugal sieves, which have very high velocity differences between the stationary outer screen and the rapidly rotating blades. The new design does not depend on airflow in the sieving unit, so it will function just as well in vacuum as in air. One advantage of the innovation for batch sieving is that a batch-mode centrifugal sieve may accomplish the same sieving operation in much less time than a conventional stacked set of vibrated screens (which utilize gravity as the primary driving force for size separation). In continuous mode, the centrifugal sieves can provide steady streams of fine and coarse material separated from a mixed feedstock flow stream. The centrifugal sieves can be scaled to any desired size and/or mass flow rate. Thus, they could be made in sizes suitable for small robotic exploratory missions, or for semi-permanent processing of regolith for extraction of volatiles of minerals. An advantage of the continuous-mode system is that it can be made with absolutely no gravity flow components for feeding material into, or for extracting the separated size streams from, the centrifugal sieve. Thus, the system is capable of functioning in a true microgravity environment. Another advantage of the continuous-mode system is that some embodiments of the innovation have no internal blades or vanes, and thus, can be designed to handle a very wide range of feedstock sizes, including occasional very large oversized pieces, without jamming or seizing up.
Thorisdottir, Rannveig Linda; Sundgren, Johanna; Sheikh, Rafi; Blohmé, Jonas; Hammar, Björn; Kjellström, Sten; Malmsjö, Malin
2018-05-28
To evaluate the digital KM screen computerized ocular motility test and to compare it with conventional nondigital techniques using the Hess and Lees screens. Patients with known ocular deviations and a visual acuity of at least 20/100 underwent testing using the digital KM screen and the Hess and Lees screen tests. The examination duration, the subjectively perceived difficulty, and the patient's method of choice were compared for the three tests. The accuracy of test results was compared using Bland-Altman plots between testing methods. A total of 19 patients were included. Examination with the digital KM screen test was less time-consuming than tests with the Hess and Lees screens (P < 0.001 and P = 0.003, resp., compared with the digital KM screen). Patients found the test with the digital KM screen easier to perform than the Lees screen test (P = 0.009) but of similar difficulty to the Hess screen test (P = 0.203). The majority of the patients (83%) preferred the digital KM screen test to both of the other screen methods (P = 0.008). Bland-Altman plots showed that the results obtained with all three tests were similar. The digital KM screen is accurate and time saving and provides similar results to Lees and Hess screen testing. It also has the advantage of a digital data analysis and registration. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.
Scale-Up of an Human Papillomavirus Testing Implementation Program in El Salvador
Cremer, Miriam; Maza, Mauricio; Alfaro, Karla; Morales Velado, Mario; Felix, Juan; Castle, Philip E.; Kim, Jane; Gage, Julia C.
2017-01-01
Objective The Cervical Cancer Prevention in El Salvador is a demonstration project to introduce a lower-cost human papillomavirus (HPV)-DNA test into a public sector project. Started in October 2012, The Cervical Cancer Prevention in El Salvador consists of 3 phases and will ultimately screen 30,000 women. Results of phase 2 of the project are presented. The objective of this project was to compare colposcopy and noncolposcopy-based management for HPV-positive women. Material and Methods In phase 2, a total of 8,050 women, aged 30 to 49 years, were screened; 6,761 provided both self- and provider-collected specimens and 1,289 provided only provider-testing specimens. HPV results from self-collected specimens were not used in clinical management decisions. Women with provider-collected HPV-positive results were treated based on the strategy assigned to their community; the strategy was colposcopy management (CM) or screen-and-treat (ST) management if they were cryotherapy eligible or colposcopy if not eligible. Outcomes were assessed 6 months after screening. Results Overall, 489 (12.3%) of 3,963 women receiving CM and 465 (11.4%) of 4,087 women receiving ST tested HPV positive. In the CM cohort, 216 (44.2%) of 489 completed their intervention (203 treated, 11 diagnosed negative, 2 pregnant). In the ST cohort, 411 (88.4%) of 465 completed their intervention (407 treated, 2 diagnosed negative, 1 pregnant). Overall agreement between HPV test results from self-collected and provider-collected specimens was 93.7%, with a κ value of 0.70 (95% CI = 0.68–0.73). Conclusions Human papillomavirus testing with ST management resulted in an approximately twice completion rate compared with CM management. Agreement between self- and provider-based sampling was good and might be used to extend screening to women in areas that are more difficult to reach. PMID:27922905
Baker, David W; Brown, Tiffany; Buchanan, David R; Weil, Jordan; Cameron, Kenzie A; Ranalli, Lauren; Ferreira, M Rosario; Stephens, Quinn; Balsley, Kate; Goldman, Shira N; Wolf, Michael S
2013-04-29
Colorectal cancer (CRC) is common and leads to significant morbidity and mortality. Although screening with fecal occult blood testing (FOBT) or endoscopy has been shown to decrease CRC mortality, screening rates remain suboptimal. Screening rates are particularly low for people with low incomes and members of underrepresented minority groups. FOBT should be done annually to detect CRC early and to reduce CRC mortality, but this often does not occur. This paper describes the design of a multifaceted intervention to increase long-term adherence to FOBT among poor, predominantly Latino patients, and the design of a randomized controlled trial (RCT) to test the efficacy of this intervention compared to usual care. In this RCT, patients who are due for repeat FOBT are identified in the electronic health record (EHR) and randomized to receive either usual care or a multifaceted intervention. The usual care group includes multiple point-of-care interventions (e.g., standing orders, EHR reminders), performance measurement, and financial incentives to improve CRC screening rates. The intervention augments usual care through mailed CRC screening test kits, low literacy patient education materials, automated phone and text message reminders, in-person follow up calls from a CRC Screening Coordinator, and communication of results to patients along with a reminder card highlighting when the patient is next due for screening. The primary outcome is completion of FOBT within 6 months of becoming due. The main goal of the study is to determine the comparative effectiveness of the intervention compared to usual care. Additionally, we want to assess whether or not it is possible to achieve high rates of adherence to CRC screening with annual FOBT, which is necessary for reducing CRC mortality. The intervention relies on technology that is increasingly widespread and declining in cost, including EHR systems, automated phone and text messaging, and FOBTs for CRC screening. We took this approach to ensure generalizability and allow us to rapidly disseminate the intervention through networks of community health centers (CHCs) if the RCT shows the intervention to be superior to usual care. ClinicalTrials.gov NCT01453894.
The microassay on a card: A rugged, portable immunoassay
NASA Technical Reports Server (NTRS)
Kidwell, David
1991-01-01
The Microassay on a Card (MAC) is a portable, hand-held, non-instrumental immunoassay that can test for the presence of a wide variety of substances in the environment. The MAC is a simple device to use. A drop of test solution is placed on one side of the card and within five minutes a color is developed on the other side in proportion to the amount of substance in the test solution, with sensitivity approaching 10 ng/ml. The MAC is self-contained and self-timed; no reagents or timing is necessary. The MAC may be configured with multiple wells to provide simultaneous testing for multiple species. As envisioned, the MAC will be employed first as an on-site screen for drugs of abuse in urine or saliva. If the MAC can be used as a screen of saliva for drugs of abuse, it could be applied to driving while intoxicated, use of drugs on the job, or testing of the identity of seized materials. With appropriate modifications, the MAC also could be used to test for environmental toxins or pollutants.
[Costs of Chagas' disease screening test in blood donors in two Colombian blood banks, 2015].
Alvis, Nelson José; Díaz, Diana Patricia; Castillo, Liliana; Alvis, Nelson Rafael; Bermúdez, María Isabel; Berrío, Olga Maritza; Beltrán, Mauricio; Castañeda-Orjuela, Carlos Andrés
2018-03-15
Transfusion is a mechanism of transmission of Chagas' disease. There are no studies on the costs of the screening test in Colombian blood banks. To estimate the costs of the screening test for Chagas' disease among blood donors in two Colombian blood banks, 2015. We conducted a micro-costing study from the perspective of the health care provider to estimate the cost of Chagas' disease testing in two blood banks, Banco de Sangre de la Cruz Roja, Seccional Bolívar, and Banco de Sangre del Hospital de Yopal, Casanare, taking into account four cost categories: 1) Administrative costs: public services and insurance costs were calculated based on the blood bank area in square meters; 2) capital costs: building and equipment costs that were annualized using a 3% discount rate and a lifespan of 20 years for building and five for equipment; 3) costs of Chagas' disease test materials and reagents adjusted by blood bank production level, and 4) costs of staff in charge of Chagas' disease test processing. The costs of transfusion bagsand immunohematology tests are also reported. The cost of Chagas' disease test in the blood bank of Seccional Bolívar was COP$ 37,804 (USD$ 12), and the blood bag and immunohematology test costs were COP$ 25,941 (USD$ 8.2) and COP$ 6,800 (USD$ 2.2), respectively. In the blood bank of Yopal, Casanare, the costs were COP$ 77,384 (USD$ 24.6), COP$ 30,141 (USD$ 9.6) and COP$ 12,627 (USD$ 4), respectively. Personnel cost accounted for the highest percentage of the total cost for both blood banks (47.5% in Seccional Bolívar, and 55.7% in Yopal, Casanare). Our results are an important input for the planning of services and cost-effectiveness studies for screening tests for Chagas' disease in Colombian blood banks.
de Almeida, Sergio Monteiro; Kamat, Rujvi; Cherner, Mariana; Umlauf, Anya; Ribeiro, Clea Elisa; de Pereira, Ana Paula; Franklin, Donald; Heaton, Robert K.; Ellis, Ronald J.
2016-01-01
Objectives The International HIV Dementia Scale (IHDS) was developed to screen for HIV-associated dementia (HAD), but it has been used more generally for HIV-associated neurocognitive disorder (HAND). This study sought to examine the accuracy of the IHDS in a cohort of Brazilian HIV-infected individuals and compare its performance to an alternative screening battery for detecting HAND. Methods 108 participants (including 60 HIV-infected persons), completed the IHDS and a gold standard neuropsychological (NP) battery of 17 tests. As alternative screening method, all possible three-test combinations from the NP battery were examined and a superiority index (a marker of specificity and sensitivity) was calculated. Results Sensitivity and specificity to HAND using the standard IHDS cutpoint of 10 were 36% and 75% respectively. The best balance between sensitivity and specificity was accomplished with a modified cutpoint of 11.5, which yielded sensitivity of 72% and specificity of 58%. The top two most sensitive test combinations, compared to the gold standard NP battery, were Trail Making Test A, WAIS-III Digit Symbol (DS) and HVLT-R Total Recall (sensitivity 91%, specificity 96%), and DS, BVMT-R Total Recall and Grooved Pegboard Test-Dominant Hand (sensitivity 94%, specificity 91%). Conclusions Both test combinations can be administered in under 10 minutes and were more accurate than the IHDS in classifying HIV+ participants as NP impaired or unimpaired. These data suggest that demographically corrected T-scores from commonly used NP measures with modest time and material demands can improve identification of patients with HAND who may benefit from a more extensive NP examination. PMID:27828876
Screening for colon cancer; Colonoscopy - screening; Sigmoidoscopy - screening; Virtual colonoscopy - screening; Fecal immunochemical test; Stool DNA test; sDNA test; Colorectal cancer - screening; Rectal ...
Dörries, Hans-Henno; Remus, Ivonne; Grönewald, Astrid; Grönewald, Cordt; Berghof-Jäger, Kornelia
2010-03-01
The number of commercially available genetically modified organisms (GMOs) and therefore the diversity of possible target sequences for molecular detection techniques are constantly increasing. As a result, GMO laboratories and the food production industry currently are forced to apply many different methods to reliably test raw material and complex processed food products. Screening methods have become more and more relevant to minimize the analytical effort and to make a preselection for further analysis (e.g., specific identification or quantification of the GMO). A multiplex real-time PCR kit was developed to detect the 35S promoter of the cauliflower mosaic virus, the terminator of the nopaline synthase gene of Agrobacterium tumefaciens, the 35S promoter from the figwort mosaic virus, and the bar gene of the soil bacterium Streptomyces hygroscopicus as the most widely used sequences in GMOs. The kit contains a second assay for the detection of plant-derived DNA to control the quality of the often processed and refined sample material. Additionally, the plant-specific assay comprises a homologous internal amplification control for inhibition control. The determined limits of detection for the five assays were 10 target copies/reaction. No amplification products were observed with DNAs of 26 bacterial species, 25 yeasts, 13 molds, and 41 not genetically modified plants. The specificity of the assays was further demonstrated to be 100% by the specific amplification of DNA derived from reference material from 22 genetically modified crops. The applicability of the kit in routine laboratory use was verified by testing of 50 spiked and unspiked food products. The herein described kit represents a simple and sensitive GMO screening method for the reliable detection of multiple GMO-specific target sequences in a multiplex real-time PCR reaction.
NASA Technical Reports Server (NTRS)
Koumal, D. E.
1979-01-01
The design and evaluation of built-up attachments and bonded joint concepts for use at elevated temperatures is documented. Joint concept screening, verification of GR/PI material, fabrication of design allowables panels, definition of test matrices, and analysis of bonded and bolted joints are among the tasks completed. The results provide data for the design and fabrication of lightly loaded components for advanced space transportation systems and high speed aircraft.
Pulsed single-blow regenerator testing
NASA Technical Reports Server (NTRS)
Oldson, J. C.; Knowles, T. R.; Rauch, J.
1992-01-01
A pulsed single-blow method has been developed for testing of Stirling regenerator materials performance. The method uses a tubular flow arrangement with a steady gas flow passing through a regenerator matrix sample that packs the flow channel for a short distance. A wire grid heater spanning the gas flow channel is used to heat a plug of gas by approximately 2 K for approximately 350 ms. Foil thermocouples monitor the gas temperature entering and leaving the sample. Data analysis based on a 1D incompressible-flow thermal model allows the extraction of Stanton number. A figure of merit involving heat transfer and pressure drop is used to present results for steel screens and steel felt. The observations show a lower figure of merit for the materials tested than is expected based on correlations obtained by other methods.
Gent, M R; Menéndez, M; Muñiz, H; Torno, S
2015-09-01
A compilation of the physical properties of materials which might typically occur in automobile shredder residue and an analysis of their suitability for the separation of materials in fine (<15mm) heavy fluff ASR (fhf-ASR) is presented. Differences in density and resistance to crushing of fhf-ASR materials were identified as potentially the most suitable low cost, technologically simple means for the separating this waste into its three principal components - metals, minerals (glass/stones) and organics (plastics). Results presented of laboratory scale tests demonstrate that fhf-ASR can in large part be separated into three principal components. Tests were conducted with 0.63-2.0mm and 2-10mm fractions. Recovery of plastics by density separations were conducted with water only jigs for the 2-10mm fraction and shaker tables for the 0.63-2mm fraction. Comparisons are presented of the separations of glass and stones from metals obtained by linear screening and vibratory screening of roller mill and impact mill crushing products of the high density 2-10mm fraction. Equipment used for these tests are of a laboratory or demonstrative scale. It is reasonable to anticipate that industrial scale processing would produce significantly better results. The 2-15mm fraction was found to constitute 91.6% of the fhf-ASR sampled. The metals content of the 2-10mm portion of this fraction was upgraded from 2.5% to 31% and 76.9% with recoveries varying inversely with grade from 91.9% to 40.1%. From 63.6% to 17.1% with a recovery of 93.5% of the organic materials. A residual product of fine sand of crushed glass/stones of 99.4% purity recovered 71.3% of these. Copyright © 2015 Elsevier Ltd. All rights reserved.
MYCOLOGICAL ANALYSIS AND AFLATOXIN B1 CONTAMINANT ESTIMATION OF HERBAL DRUG RAW MATERIALS
Rajeshwari, Puttaswamy; Raveesha, KoteshwarAnandrao
2016-01-01
Background: The present study explores the fungal contamination of important herbal drug raw materials (HDRM), which are widely used in the preparation of many herbal drugs. Understanding of the microbial contamination status of HDRM is one of the important steps to ensure the safety and efficacy of herbal drugs. Materials and Methods: Eighteen samples of six herbal drug raw materials (HDRM) viz., Acorus calamus Linn., Cassia angustifolia Vahl., Centella asiatica (Linn.) Urban, Myristica fragrans Houtt., Tinospora cardifolia (Wild) Miers and Withania somnifera (Linn.) Dunal, were screened for fungal contamination, by employing serial dilution method. All the isolates of Aspergillus flavus were screened for their ability to produce aflatoxin B1 (AB1) and highly contaminated samples were subjected to AB1 estimation by using Thin Layer Chromatography (TLC), spectrophotometric method and occurrence of Aflatoxin B1 was confirmed by Liquid Chromatography-Mass Spectrometry analysis (LCMS). Results: A total of 302 isolates of 42 fungal species belonging to 17 genera were found in association with test the samples. More than 61% of A. flavus isolates tested positive for production of AB1 and highest yield recorded was 5008.20 ppb from the isolates of T. cordifolia. Amongthesix highly contaminated samples three samples tested positive for AB1. Highest AB1 was recorded from T. cordifolia (104.19 μg/kg), followed by A. calamus (13.73 μg/kg) and M. fragrans (12.02 μg/kg). Conclusion: Assessment of fungal and mycotoxin contamination should be a part of the quality check while selecting HDRM for manufacture of herbal products. Safe processing and storage practices are necessary. PMID:28487902
Preliminary results of accelerated exposure testing of solar cell system components
NASA Technical Reports Server (NTRS)
Anagnostou, E.; Forestieri, A. F.
1977-01-01
Plastic samples and solar cell sub modules were exposed to an accelerated outdoor environment in Arizona and an accelerated simulated environment in a cyclic ultraviolet exposure tester which included humidity exposure. These tests were for preliminary screening of materials suitable for use in the manufacture of solar cell modules which are to have a 20-year lifetime. The samples were exposed for various times up to six months, equivalent to a real time exposure of four years. Suitable materials were found to be FEP-A, FEP-C, PFA, acrylic, silicone compounds and adhesives and possibly parylene. The method of packaging the sub modules was also found to be important to their performance.
Zeman, Herbert D.
1994-01-01
A scintillator screen for an X-ray system includes a substrate of low-Z material and bodies of a high-Z material embedded within the substrate. By preselecting the size of the bodies embedded within the substrate, the spacial separation of the bodies and the thickness of the screen, the sensitivity of the screen to X-rays within a predetermined energy range can be predicted.
NASA Technical Reports Server (NTRS)
Hoeppner, David W.; Pettit, Donald E.; Feddersen, Charles E.; Hyler, Walter S.
1968-01-01
The specific experimental investigation undertaken was designed to answer these questions on Ti-6Al-4V in the solution treated and aged condition. The defect growth and fracture characteristics were studied in parent (unwelded) and welded sheet material. The results of the study indicate that cryogenic proof testing will screen smaller size defects than proof testing at ambient conditions. However some unusual crack growth behavior during the proof test simulation suggests that some further study be made of stress and time duration effects.
Gómez-Bombarelli, Rafael; Aguilera-Iparraguirre, Jorge; Hirzel, Timothy D; Duvenaud, David; Maclaurin, Dougal; Blood-Forsythe, Martin A; Chae, Hyun Sik; Einzinger, Markus; Ha, Dong-Gwang; Wu, Tony; Markopoulos, Georgios; Jeon, Soonok; Kang, Hosuk; Miyazaki, Hiroshi; Numata, Masaki; Kim, Sunghan; Huang, Wenliang; Hong, Seong Ik; Baldo, Marc; Adams, Ryan P; Aspuru-Guzik, Alán
2016-10-01
Virtual screening is becoming a ground-breaking tool for molecular discovery due to the exponential growth of available computer time and constant improvement of simulation and machine learning techniques. We report an integrated organic functional material design process that incorporates theoretical insight, quantum chemistry, cheminformatics, machine learning, industrial expertise, organic synthesis, molecular characterization, device fabrication and optoelectronic testing. After exploring a search space of 1.6 million molecules and screening over 400,000 of them using time-dependent density functional theory, we identified thousands of promising novel organic light-emitting diode molecules across the visible spectrum. Our team collaboratively selected the best candidates from this set. The experimentally determined external quantum efficiencies for these synthesized candidates were as large as 22%.
NASA Astrophysics Data System (ADS)
Gómez-Bombarelli, Rafael; Aguilera-Iparraguirre, Jorge; Hirzel, Timothy D.; Duvenaud, David; MacLaurin, Dougal; Blood-Forsythe, Martin A.; Chae, Hyun Sik; Einzinger, Markus; Ha, Dong-Gwang; Wu, Tony; Markopoulos, Georgios; Jeon, Soonok; Kang, Hosuk; Miyazaki, Hiroshi; Numata, Masaki; Kim, Sunghan; Huang, Wenliang; Hong, Seong Ik; Baldo, Marc; Adams, Ryan P.; Aspuru-Guzik, Alán
2016-10-01
Virtual screening is becoming a ground-breaking tool for molecular discovery due to the exponential growth of available computer time and constant improvement of simulation and machine learning techniques. We report an integrated organic functional material design process that incorporates theoretical insight, quantum chemistry, cheminformatics, machine learning, industrial expertise, organic synthesis, molecular characterization, device fabrication and optoelectronic testing. After exploring a search space of 1.6 million molecules and screening over 400,000 of them using time-dependent density functional theory, we identified thousands of promising novel organic light-emitting diode molecules across the visible spectrum. Our team collaboratively selected the best candidates from this set. The experimentally determined external quantum efficiencies for these synthesized candidates were as large as 22%.
Wet voice as a sign of penetration/aspiration in Parkinson's disease: does testing material matter?
Sampaio, Marília; Argolo, Natalie; Melo, Ailton; Nóbrega, Ana Caline
2014-10-01
Wet voice is a perceptual vocal quality that is commonly used as an indicator of penetration and/or aspiration in clinical swallowing assessments and bedside screening tests. Our aim was to describe the clinimetric characteristics of this clinical sign using various fluid materials and one solid food in the Parkinson's disease (PD) population. Consecutive PD individuals were submitted for simultaneous fiberoptic endoscopic evaluation of swallowing (FEES) and voice recording. Speech therapists rated the presence or absence of wetness and other voice abnormalities. Two binary endpoints of FEES were selected for comparison with an index test: low penetration (LP) and low penetration and/or aspiration (LP/ASP). The accuracy of wet voice changed according to the testing material in PD patients. Overall, the specificity of this indicator was better than its sensitivity, and the wafer cookie and yogurt drink yielded the best indices. Our data show that wet voice is clearly indicative of LP or LP/ASP in PD patients in case of positive test. However, in the case of a negative result, the wet voice test should be repeated or combined with other clinical tests to include or exclude the risk of LP or LP/ASP.
Poonual, Watcharapol; Navacharoen, Niramon; Kangsanarak, Jaran; Namwongprom, Sirianong
2016-01-01
Objective To define the risk factors for hearing loss in infants (aged 3 months) under universal hearing screening program. Materials and methods A total of 3,120 infants (aged 3 months) who underwent hearing screening using a universal hearing screening program using automated otoacoustic emission test between November 1, 2010 and May 31, 2012 in Uttaradit Hospital, Buddhachinaraj Hospital, and Sawanpracharuk Hospital (tertiary hospitals) located in Northern Thailand were included in this prospective cohort study. Results Of the 3,120 infants, 135 (4.3%) were confirmed to have hearing loss with the conventional otoacoustic emission test. Five of these 135 infants (3.7%) with hearing loss showed test results consistent with auditory brainstem responses. From the univariable analysis, there were eleven potential risk factors associated with hearing deterioration. On multivariable analysis, the risk factors independently associated with hearing loss at 3 months were birth weight 1,500–2,500 g (risk ratio [RR] 1.6, 95% confidence interval [CI] 1.1–2.6), APGAR score <6 at 5 minutes (RR 2.2, 95% CI 1.1–4.4), craniofacial anomalies (RR 2.5, 95% CI 1.6–4.2), sepsis (RR 1.8, 95% CI 1.0–3.2), and ototoxic exposure (RR 4.1, 95% CI 1.9–8.6). Conclusion This study concluded that low birth weight, APGAR score <6 at 5 minutes, craniofacial anomalies, sepsis, and ototoxic exposure are the risk factors for bilateral hearing loss in infants (aged 3 months) and proper tests should be performed to identify these risk factors. As an outcome, under the present circumstances, it is suggested that infirmary/physicians/general practitioners/health action centers/polyclinics should carry out universal hearing screening in all infants before 36 weeks. The public health policy of Thailand regarding a universal hearing screening program is important for the prevention of disability and to enhance people’s quality of life. PMID:26766912
Marks, D; Wonderling, D; Thorogood, M; Lambert, H; Humphries, S E; Neil, H A
2000-01-01
In the majority of people with familial hypercholesterolaemia (FH) the disorder is caused by a mutation of the low-density lipoprotein receptor gene that impairs its proper function, resulting in very high levels of plasma cholesterol. Such levels result in early and severe atherosclerosis, and hence substantial excess mortality from coronary heart disease. Most people with FH are undiagnosed or only diagnosed after their first coronary event, but early detection and treatment with hydroxymethylglutaryl-coenzyme (HMG CoA) reductase inhibitors (statins) can reduce morbidity and mortality. The prevalence of FH in the UK population is estimated to be 1 in 500, which means that approximately 110,000 people are affected. To evaluate whether screening for FH is appropriate. To determine which system of screening is most acceptable and cost-effective. To assess the deleterious psychosocial effects of genetic and clinical screening for an asymptomatic treatable inherited condition. To assess whether the risks of screening outweigh potential benefits. Relevant papers were identified through a search of the electronic databases. Additional papers referenced in the search material were identified and collected. Known researchers in the field were contacted and asked to supply information on unpublished or ongoing studies. INCLUSION/EXCLUSION CRITERIA: SCREENING AND TREATMENT: The review included studies of the mortality and morbidity associated with FH, the effectiveness and cost of treatment (ignoring pre-statin therapies in adults), and of the effectiveness or cost of possible screening strategies for FH. PSYCHOSOCIAL EFFECTS OF SCREENING: The search for papers on the psychological and social effects of screening for a treatable inherited condition was limited to the last 5 years because recent developments in genetic testing have changed the nature and implications of such screening tests. Papers focusing on genetic testing for FH and breast cancer were included. Papers relating to the risk of coronary heart disease with similarly modifiable outcome (non-FH) were also included. DATA EXTRACTION AND ASSESSMENT OF VALIDITY: A data assessment tool was designed to assess the quality and validity of the papers which reported primary data for the social and psychological effects of screening. Available guidelines for systematically reviewing papers concentrated on quantitative methods, and were of limited relevance. An algorithm was developed which could be used for both the qualitative and quantitative literature. MODELLING METHODS: A model was constructed to investigate the relative cost and effectiveness of various forms of population screening (universal or opportunistic) and case-finding screening (screening relatives of known FH cases). All strategies involved a two-stage process: first, identifying those people with cholesterol levels sufficiently elevated to be compatible with a diagnosis of FH, and then either making the diagnosis based on clinical signs and a family history of coronary disease or carrying out genetic tests. Cost-effectiveness has been measured in terms of incremental cost per year of life gained. MODELLING COST-EFFECTIVENESS: FH is a life-threatening condition with a long presymptomatic state. Diagnostic tests are reasonably reliable and acceptable, and treatment with statins substantially improves prognosis. Therefore, it is appropriate to consider systematic screening for this condition. Case finding amongst relatives of FH cases was the most cost-effective strategy, and universal systematic screening the least cost-effective. However, when targeted at young people (16 year olds) universal screening was also cost-effective. Screening patients admitted to hospital with premature myocardial infarction was also relatively cost-effective. Screening is least cost-effective in men aged over 35 years, because the gains in life expectancy are small. (ABSTRACT TRUNCA
Castañeda, Sheila F; Bharti, Balambal; Espinoza-Giacinto, Rebeca Aurora; Sanchez, Valerie; O'Connell, Shawne; Muñoz, Fatima; Mercado, Sylvia; Meza, Marie Elena; Rojas, Wendy; Talavera, Gregory A; Gupta, Samir
2017-06-20
Regular use of colorectal cancer screening can reduce incidence and mortality, but participation rates remain low among low-income, Spanish-speaking Latino adults. We conducted two distinct pilot studies testing the implementation of evidence-based interventions to promote fecal immunochemical test (FIT) screening among Latinos aged 50-75 years who were not up-to-date with CRC screening (n = 200) at a large Federally Qualified Health Center (FQHC) in San Diego, CA. One pilot focused on an opportunistic clinic visit "in-reach" intervention including a 30-min session with a patient navigator, review of an educational "flip-chart," and a take-home FIT kit with instructions. The second pilot was a system-level "outreach" intervention consisting of mailed materials (i.e., FIT kit, culturally and linguistically tailored instructions, and a pre-paid return envelope). Both received follow-up calls to promote screening completion and referrals for additional screening and treatment if needed. The primary outcome was FIT kit completion and return within 3 months assessed through electronic medical records. The in-reach pilot consisted of mostly insured (85%), women (82%), and Spanish-speaking (88%) patients. The outreach pilot consisted of mostly of Spanish-speaking (73%) women (64%), half of which were insured (50%). At a 3-month follow-up, screening completion was 76% for in-reach and 19% for outreach. These data demonstrate that evidence-based strategies to promote CRC screening can be implemented successfully within FQHCs, but implementation (particularly of mailed outreach) may require setting and population-specific optimization. Patient, provider, and healthcare system related implementation approaches and lessons learned from this study may be implemented in other primary care settings.
Evaluation of ‘vision screening’ program for three to six-year-old children in the Republic of Iran
Khandekar, Rajiv; Parast, Noa; Arabi, Ashraf
2009-01-01
Background: Since 1996, vision screening of three to six-year-old children is conducted every year in Iran. We present outcomes of project review held in August 2006. Materials and Methods: Kindergarten teachers examined vision by using Snellen's illiterate ‘E’ chart. They used torchlight to detect strabismus. On a repeat test, if either eye had vision <20/30, the child was referred to the optometrist. A pediatric ophthalmologist examined and managed children with strabismus or amblyopia. Provincial managers supervised the screening program. The evaluator team assessed the coverage, yield, quality and feasibility, and cost-effectiveness of vision screening, as well as magnitude of amblyopia, and its risk factors. Result: In 2005, 1.4 million (67%) children were examined in all provinces of Iran. Opticians examined 90,319 (61%) children with defective vision that were referred to them. The prevalence of uncorrected refractive error, strabismus and amblyopia was 3.82% (95% CI 3.79 – 3.85), 0.39% (95% CI 0.38 – 0.40) and 1.25% (95% CI 1.24 – 1.26) respectively. Validity test of 7,768 children had a sensitivity of 74.5% (95% CI 72.7 – 76.3) and specificity of 97.2% (95% CI 96.7 – 97.7). The cost of amblyopia screening was US $ 1.5 per child. While the cost of screening and treating one child with amblyopia was US $ 245. Conclusion: A review of the vision screening of children in Iran showed it with screening and useful exercise and had a yield of 1:21. The coverage of vision screening was low and the management of children with amblyopia, low vision and refractive error needed strengthening. PMID:19861745
Hydrologic Tests at Characterization Wells R-9i, R-13, R-19, R-22, and R-31, Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
S.G.McLin; W.J. Stone
2004-06-01
Hydrologic information is essential for environmental efforts at Los Alamos National Laboratory. Testing at new characterization wells being drilled to the regional aquifer (''R wells'') to improve the conceptual hydrogeologic model of the Pajarito Plateau is providing such information. Field tests were conducted on various zones of saturation penetrated by the R wells to collect data needed for determining hydraulic properties. This document provides details of the design and execution of testing as well as an analysis of data for five new wells: R-9i, R-13, R-19, R-22, and R-31. One well (R-13) was evaluated by a pumping test and themore » rest (R-9i, R-19, R-22, and R-31) were evaluated by injection tests. Characterization well R-9i is located in Los Alamos Canyon approximately 0.3 mi west of the Route 4/Route 502 intersection. It was completed at a depth of 322 ft below ground surface (bgs) in March 2000. This well was constructed with two screens positioned below the regional water table. Both screens were tested. Screen 1 is completed at about 189-200 ft bgs in fractured basalt, and screen 2 is completed at about 270-280 ft bgs in massive basalt. Specific capacity analysis of the screen 1 data suggests that the fractured basalt has a transmissivity (T) of 589 ft{sup 2}/day and corresponds to a hydraulic conductivity (K) of 7.1 ft/day based on a saturated thickness of 83 ft. The injection test data from the massive basalt near screen 2 were analyzed by the Bouwer-Rice slug test methodology and suggest that K is 0.11 ft/day, corresponding to a T of about 2.8 ft{sup 2}/day based on a saturated thickness of 25 ft. Characterization well R-13 is located in Mortandad Canyon just west of the eastern Laboratory boundary. It was completed at a depth of 1029 ft bgs in February 2002. This well was constructed with one 60-ft long screen positioned about 125 ft below the regional water table. This screen is completed at about 958-1019 ft bgs and straddles the geologic contact between the Puye fanglomerate and unassigned pumiceous units. The specific capacity analysis of a 12 minute pumping test indicates that the Puye fanglomerates near the R-13 screen have a T of 5269 ft{sup 2}/day and correspond to a hydraulic conductivity (K) of 17.6 ft/day based on a saturated thickness of 300 ft. Characterization well R-19 is located east of firing site IJ in Technical Area (TA) 36 on the mesa between Three-mile and Potrillo Canyons. It was completed at a depth of 1885 ft bgs in April 2000. This well was constructed with two screens positioned above the regional water table and five screens positioned below the regional water table. Only the bottom two screens were tested. Screen 6 is completed at about 1727-1734 ft bgs in Puye fanglomerate, and screen 7 is completed at about 1832-1849 ft bgs in Puye fanglomerate. Specific capacity analysis of the screen 6 data suggests that T is about 6923 ft{sup 2}/day and corresponds to a K of 18.6 ft/day based on a saturated thickness of 373 ft. Specific capacity analysis of the screen 7 data suggests that T is about 8179 ft{sup 2}/day and corresponds to a K of 22.0 ft/day based on a saturated thickness of 373 ft. Characterization well R-22 is located on Mesita del Buey between Canada del Buey and Pajarito Canyons immediately east of Material Disposal Area (MDA) G in TA-54. It was completed at a depth of 1489 ft bgs in October 2000. This well was constructed with five screens positioned at or below the regional water table; however, only screens 2-5 were tested. Screen 1 is completed at the regional water table at about 872-914 ft bgs in Cerros del Rio basalt. Screen 2 is completed at about 947-989 ft bgs in Cerros del Rio basalt. Screen 3 is completed at about 1272-1279 ft bgs in Puye fanglomerate. Screen 4 is completed at about 1378-1452 ft bgs in older basalt. Screen 5 is completed at about 1447-1452 ft bgs in older fanglomerate. Bouwer-Rice analyses of the injection-test recovery data suggest K values of 0.04, 0.32, 0.54, and 0.27 ft/day for screens 2, 3, 4, and 5, respectively. These values correspond to T values of 2.8, 15.8, 26.5, and 11.6 ft{sup 2}/day, respectively, for screens 2, 3, 4, and 5. These analyses are based on saturated thicknesses of 69.5 ft, 49.4 ft, 49.0 ft, and 43.0 ft, respectively. Characterization well R-31 is located at TA-39 in the north fork of lower Ancho Canyon. It was completed at a depth of 1103 ft bgs in April 2000. This well was constructed with one screen positioned above the regional water table, and four screens position at or below the regional water table.« less
Hofmann, Julia; Kien, Christina; Gartlehner, Gerald
2015-01-01
Evidence-based information materials about the pros and cons of cancer screening are important sources for men and women to decide for or against cancer screening. The aim of this paper was to compare recommendations from different cancer institutions in German-speaking countries (Austria, Germany, and Switzerland) regarding screening for breast, cervix, colon, and prostate cancer and to assess the quality and development process of patient information materials. Relevant information material was identified through web searches and personal contact with cancer institutions. To achieve our objective, we employed a qualitative approach. The quality of 22 patient information materials was analysed based on established guidance by Bunge et al. In addition, we conducted guided interviews about the process of developing information materials with decision-makers of cancer institutes. Overall, major discrepancies in cancer screening recommendations exist among the Austrian, German, and Swiss cancer institutes. Process evaluation revealed that crucial steps of quality assurance, such as assembling a multi-disciplinary panel, assessing conflicts of interest, or transparency regarding funding sources, have frequently not been undertaken. All information materials had substantial quality deficits in multiple areas. Three out of four institutes issued information materials that met fewer than half of the quality criteria. Most patient information materials of cancer institutes in German-speaking countries are fraught with substantial deficits and do not provide an objective source for patients to be able to make an informed decision for or against cancer screening. Copyright © 2015. Published by Elsevier GmbH.
Materials screening chamber for testing materials resistance to atomic oxygen
NASA Technical Reports Server (NTRS)
Pippin, H. G.; Carruth, Ralph
1989-01-01
A unique test chamber for exposing material to a known flux of oxygen atoms is described. The capabilities and operating parameters of the apparatus include production of an oxygen atom flux in excess of 5 x 10 to the 16th atoms/sq cm-sec, controlled heating of the sample specimen, RF circuitry to contain the plasma within a small volume, and long exposure times. Flux measurement capabilities include a calorimetric probe and a light titration system. Accuracy and limitations of these techniques are discussed. An extension to the main chamber to allow simultaneous ultraviolet and atomic oxygen exposure is discussed. The oxygen atoms produced are at thermal energies. Sample specimens are maintained at any selected temperature between ambient and 200 C, to within + or - 2 C. A representative example of measurements made using the chamber is presented.
Advanced screening of electrode couples
NASA Technical Reports Server (NTRS)
Giner, J. D.; Cahill, K.
1980-01-01
The chromium (Cr(3+)/Cr(2+)) redox couple (electrolyte and electrode) was investigated to determine its suitability as negative electrode for the iron (Fe(3+)/Fe(2+))-chromium (Cr(3+)/Cr(2+)) redox flow battery. Literature search and laboratory investigation established that the solubility and stability of aqueous acidic solutions of chromium(3) chloride and chromium(2) chloride are sufficient for redox battery application. Four categories of electrode materials were tested; namely, metals and metalloid materials (elements and compounds), alloys, plated materials, and Teflon-bonded materials. In all, the relative performance of 26 candidate electrode materials was evaluated on the basis of slow scan rate linear sweep voltammetry in stirred solution. No single material tested gave both acceptable anodic an acceptable cathodic performance. However, the identification of lead as a good cathodic electrocatalyst and gold as a good anodic electrocatalyst led to the invention of the lead/gold combination electrocatalyst. This type of catalyst can be fabricated in several ways and appears to offer the advantages of each metal without the disadvantages associated with their use as single materials. This lead/gold electrocatalyst was tested by NASA-Lewis Research Center in complete, flowing, redox batteries comprising a stack of several cells. A large improvement in the battery's coulombic and energy efficiency was observed.
Hydrodynamic parameters of mesh fillers relevant to miniature regenerative cryocoolers
NASA Astrophysics Data System (ADS)
Landrum, E. C.; Conrad, T. J.; Ghiaasiaan, S. M.; Kirkconnell, Carl S.
2010-06-01
Directional hydrodynamic parameters of two fine-mesh porous materials that are suitable for miniature regenerative cryocoolers were studied under steady and oscillating flows of helium. These materials included stacked discs of #635 stainless steel (wire diameter of 20.3 μm) and #325 phosphor bronze (wire diameter of 35.6 μm) wire mesh screens, which are among the commercially available fillers for use in small-scale regenerators and heat exchangers, respectively. Experiments were performed in test sections in which pressure variations across these fillers, in the axial and lateral (radial) directions, were measured under steady and oscillatory flows. The directional permeability and Forchheimer's inertial coefficient were then obtained by using a Computational Fluid Dynamics (CFD)-assisted method. The oscillatory flow experiments covered a frequency range of 50-200 Hz. The results confirmed the importance of anisotropy in the mesh screen fillers, and indicated differences between the directional hydrodynamic resistance parameters for steady and oscillating flow regimes.
Tulliani, Jean-Marc; Baroni, Chiara; Zavattaro, Laura; Grignani, Carlo
2013-01-01
The aim of this work is to study the sensing behavior of Sr-doped hematite for soil water content measurement. The material was prepared by solid state reaction from commercial hematite and strontium carbonate heat treated at 900 °C. X-Ray diffraction, scanning electron microscopy and mercury intrusion porosimetry were used for microstructural characterization of the synthesized powder. Sensors were then prepared by uniaxially pressing and by screen-printing, on an alumina substrate, the prepared powder and subsequent firing in the 800–1,000 °C range. These sensors were first tested in a laboratory apparatus under humid air and then in an homogenized soil and finally in field. The results evidenced that the screen printed film was able to give a response for a soil matric potential from about 570 kPa, that is to say well below the wilting point in the used soil. PMID:24025555
Selection Metric for Photovoltaic Materials Screening Based on Detailed-Balance Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blank, Beatrix; Kirchartz, Thomas; Lany, Stephan
The success of recently discovered absorber materials for photovoltaic applications has been generating increasing interest in systematic materials screening over the last years. However, the key for a successful materials screening is a suitable selection metric that goes beyond the Shockley-Queisser theory that determines the thermodynamic efficiency limit of an absorber material solely by its band-gap energy. Here, we develop a selection metric to quantify the potential photovoltaic efficiency of a material. Our approach is compatible with detailed balance and applicable in computational and experimental materials screening. We use the complex refractive index to calculate radiative and nonradiative efficiency limitsmore » and the respective optimal thickness in the high mobility limit. We also compare our model to the widely applied selection metric by Yu and Zunger [Phys. Rev. Lett. 108, 068701 (2012)] with respect to their dependence on thickness, internal luminescence quantum efficiency, and refractive index. Finally, the model is applied to complex refractive indices calculated via electronic structure theory.« less
Selection Metric for Photovoltaic Materials Screening Based on Detailed-Balance Analysis
Blank, Beatrix; Kirchartz, Thomas; Lany, Stephan; ...
2017-08-31
The success of recently discovered absorber materials for photovoltaic applications has been generating increasing interest in systematic materials screening over the last years. However, the key for a successful materials screening is a suitable selection metric that goes beyond the Shockley-Queisser theory that determines the thermodynamic efficiency limit of an absorber material solely by its band-gap energy. Here, we develop a selection metric to quantify the potential photovoltaic efficiency of a material. Our approach is compatible with detailed balance and applicable in computational and experimental materials screening. We use the complex refractive index to calculate radiative and nonradiative efficiency limitsmore » and the respective optimal thickness in the high mobility limit. We also compare our model to the widely applied selection metric by Yu and Zunger [Phys. Rev. Lett. 108, 068701 (2012)] with respect to their dependence on thickness, internal luminescence quantum efficiency, and refractive index. Finally, the model is applied to complex refractive indices calculated via electronic structure theory.« less
Development of improved coating for advanced carbon-carbon components
NASA Technical Reports Server (NTRS)
Yamaki, Y. R.; Brown, J. J.
1984-01-01
Reaction sintered silicon nitride (RSSN) was studied as a substitute coating material on the carbon-carbon material (RCC) presently used as a heat shield on the space shuttle, and on advanced carbon-carbon (ACC), a later development. On RCC, RSSN showed potential in a 538 C (1000 F) screening test in which silicon carbide coated material exhibits its highest oxidation rate; RSSN afforded less protection to ACC because of a larger thermal expansion mismatch. Organosilicon densification and metallic silicon sealing methods were studied as means of further increasing the oxidation resistance of the coating, and some improvement was noted when these methods were employed.
Method to predict relative hydriding within a group of zirconium alloys under nuclear irradiation
Johnson, Jr., A. Burtron; Levy, Ira S.; Trimble, Dennis J.; Lanning, Donald D.; Gerber, Franna S.
1990-01-01
An out-of-reactor method for screening to predict relative in-reactor hydriding behavior of zirconium-bsed materials is disclosed. Samples of zirconium-based materials having different composition and/or fabrication are autoclaved in a relatively concentrated (0.3 to 1.0M) aqueous lithium hydroxide solution at constant temperatures within the water reactor coolant temperature range (280.degree. to 316.degree. C.). Samples tested by this out-of-reactor procedure, when compared on the basis of the ratio of hydrogen weight gain to oxide weight gain, accurately predict the relative rate of hyriding for the same materials when subject to in-reactor (irradiated) corrision.
Combinatorial Methodology for Screening Selectivity in Polymeric Pervaporation Membranes.
Godbole, Rutvik V; Ma, Lan; Doerfert, Michael D; Williams, Porsche; Hedden, Ronald C
2015-11-09
Combinatorial methodology is described for rapid screening of selectivity in polymeric pervaporation membrane materials for alcohol-water separations. The screening technique is demonstrated for ethanol-water separation using a model polyacrylate system. The materials studied are cross-linked random copolymers of a hydrophobic comonomer (n-butyl acrylate, B) and a hydrophilic comonomer (2-hydroxyethyl acrylate, H). A matrix of materials is prepared that has orthogonal variations in two key variables, H:B ratio and cross-linker concentration. For mixtures of ethanol and water, equilibrium selectivities and distribution coefficients are obtained by combining swelling measurements with high-throughput HPLC analysis. Based on the screening results, two copolymers are selected for further study as pervaporation membranes to quantify permeability selectivity and the flux of ethanol. The screening methodology described has good potential to accelerate the search for new membrane materials, as it is adaptable to a broad range of polymer chemistries.
Hanford Waste End Effector Phase I Test Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berglin, Eric J.; Hatchell, Brian K.; Mount, Jason C.
This test plan describes the Phase 1 testing program of the Hanford Waste End Effector (HWEE) at the Washington River Protection Solutions’ Cold Test Facility (CTF) using a Pacific Northwest National Laboratory (PNNL)-designed testing setup. This effort fulfills the informational needs for initial assessment of the HWEE to support Hanford single-shell tank A-105 retrieval. This task will install the HWEE on a PNNL-designed robotic gantry system at CTF, install and calibrate instrumentation to measure reaction forces and process parameters, prepare and characterize simulant materials, and implement the test program. The tests will involve retrieval of water, sludge, and hardpan simulantsmore » to determine pumping rate, dilution factors, and screen fouling rate.« less
A pilot study on screening blood donors with individual-donation nucleic acid testing in China
Dong, Jie; Wu, Yaling; Zhu, Hong; Li, Gan; Lv, Mengen; Wu, Daxiao; Li, Xiaotao; Zhu, Faming; Lv, Hangjun
2014-01-01
Background Nucleic acid amplification testing (NAT) is not yet obligatory in China for blood donor screening and the risk of enzyme immunoassay (EIA)-negative, NAT-reactive donations in Chinese blood donors has rarely been reported. The aim of this study was to screen a population of Chinese blood donors using a triplex individual-donation (ID)-NAT assay and assess the safety benefits of implementing NAT. Materials and methods Between 1st August, 2010 and 31st December, 2011 all donations at a Chinese blood centre were screened individually using the Procleix® Ultrio® assay, a multiplex NAT assay for the detection of hepatitis B virus (HBV) DNA, hepatitis C virus (HCV) RNA and human immunodeficiency virus-1 (HIV-1) RNA. All donations were also screened for HBsAg, anti-HIV and anti-HCV using two different EIA for each marker. Samples with discordant results between NAT and EIA were further tested with an alternative NAT assay (Cobas® TaqMan®). Potential yield cases (serologically negative/NAT-reactive donors) were further evaluated when possible. Results During the study period a total of 178,447 donations were screened by NAT and EIA, among which 169 HBV NAT yield cases (0.095%) were detected. No N AT yield cases were found for HIV-1 or HCV. For the HBV NAT yield cases, follow-up results showed that 11 (6.51%) were probable or confirmed HBV window period infections, 5 (2.96%) were chronic HBV carriers and 153 (90.53%) were probable or confirmed occult HBV infections. There was a statistically significant difference between the NAT-positive rates for first-time vs repeat donations (0.472% vs 0.146%, respectively; P<0.001). Discussion Our data demonstrate that the potential HBV yield rate was 1:1,056 for blood donations in the Zhejiang province of China. Implementation of NAT will provide a significant increment in safety relative to serological screening alone. PMID:24333061
Screening tests for hazard classification of complex waste materials - Selection of methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weltens, R., E-mail: reinhilde.weltens@vito.be; Vanermen, G.; Tirez, K.
In this study we describe the development of an alternative methodology for hazard characterization of waste materials. Such an alternative methodology for hazard assessment of complex waste materials is urgently needed, because the lack of a validated instrument leads to arbitrary hazard classification of such complex waste materials. False classification can lead to human and environmental health risks and also has important financial consequences for the waste owner. The Hazardous Waste Directive (HWD) describes the methodology for hazard classification of waste materials. For mirror entries the HWD classification is based upon the hazardous properties (H1-15) of the waste which canmore » be assessed from the hazardous properties of individual identified waste compounds or - if not all compounds are identified - from test results of hazard assessment tests performed on the waste material itself. For the latter the HWD recommends toxicity tests that were initially designed for risk assessment of chemicals in consumer products (pharmaceuticals, cosmetics, biocides, food, etc.). These tests (often using mammals) are not designed nor suitable for the hazard characterization of waste materials. With the present study we want to contribute to the development of an alternative and transparent test strategy for hazard assessment of complex wastes that is in line with the HWD principles for waste classification. It is necessary to cope with this important shortcoming in hazardous waste classification and to demonstrate that alternative methods are available that can be used for hazard assessment of waste materials. Next, by describing the pros and cons of the available methods, and by identifying the needs for additional or further development of test methods, we hope to stimulate research efforts and development in this direction. In this paper we describe promising techniques and argument on the test selection for the pilot study that we have performed on different types of waste materials. Test results are presented in a second paper. As the application of many of the proposed test methods is new in the field of waste management, the principles of the tests are described. The selected tests tackle important hazardous properties but refinement of the test battery is needed to fulfil the a priori conditions.« less
Theory and practice of conventional adventitious virus testing.
Gregersen, Jens-Peter
2011-01-01
CONFERENCE PROCEEDING Proceedings of the PDA/FDA Adventitious Viruses in Biologics: Detection and Mitigation Strategies Workshop in Bethesda, MD, USA; December 1-3, 2010 Guest Editors: Arifa Khan (Bethesda, MD), Patricia Hughes (Bethesda, MD) and Michael Wiebe (San Francisco, CA) For decades conventional tests in cell cultures and in laboratory animals have served as standard methods for broad-spectrum screening for adventitious viruses. New virus detection methods based on molecular biology have broadened and improved our knowledge about potential contaminating viruses and about the suitability of the conventional test methods. This paper summarizes and discusses practical aspects of conventional test schemes, such as detectability of various viruses, questionable or false-positive results, animal numbers needed, time and cost of testing, and applicability for rapidly changing starting materials. Strategies to improve the virus safety of biological medicinal products are proposed. The strategies should be based upon a flexible application of existing and new methods along with a scientifically based risk assessment. However, testing alone does not guarantee the absence of adventitious agents and must be accompanied by virus removing or virus inactivating process steps for critical starting materials, raw materials, and for the drug product.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richard A. Corbett; Dave Severance
2005-02-01
Formicary corrosion is an insidious form of localized pitting corrosion. Notoya (1997b) wrote, ?In Japan, this type of corrosion is found in approximately 10% of cases of premature failure of copper tubes.? Attack characteristically features very small surface pits which are not visible to the un-aided eye, and random directional changes in the underlying copper metal. Attack is rapid. Failures have occurred before installation, shortly thereafter, or within several years later. Objectives of this Research Project Conduct an in depth literature search on the subject of formicary corrosion. Define the corrosion mechanism. Develop a test method that will reproduce formicarymore » corrosion. Develop a test method for screening candidate materials that could cause formicary corrosion.« less
Thrust chamber material technology program
NASA Technical Reports Server (NTRS)
Andrus, J. S.; Bordeau, R. G.
1989-01-01
This report covers work performed at Pratt & Whitney on development of copper-based materials for long-life, reusable, regeneratively cooled rocket engine thrust chambers. The program approached the goal of enhanced cyclic life through the application of rapid solidification to alloy development, to introduce fine dispersions to strengthen and stabilize the alloys at elevated temperatures. After screening of alloy systems, copper-based alloys containing Cr, Co, Hf, Ag, Ti, and Zr were processed by rapid-solidification atomization in bulk quantities. Those bulk alloys showing the most promise were characterized by tensile testing, thermal conductivity testing, and elevated-temperature, low-cycle fatigue (LFC) testing. Characterization indicated that Cu- 1.1 percent Hf exhibited the greatest potential as an improved-life thrust chamber material, exhibiting LCF life about four times that of NASA-Z. Other alloys (Cu- 0.6 percent Zr, and Cu- 0.6 percent Zr- 1.0 percent Cr) exhibited promise for use in this application, but needed more development work to balance properties.
Salud es Vida: a Cervical Cancer Screening Intervention for Rural Latina Immigrant Women.
Luque, John S; Tarasenko, Yelena N; Reyes-Garcia, Claudia; Alfonso, Moya L; Suazo, Norma; Rebing, Laura; Ferris, Daron G
2017-12-01
This study examined the feasibility and efficacy of Salud es Vida-a promotora-led, Spanish language educational group session on cervical cancer screening (Pap tests)-self-efficacy (belief in ability to schedule and complete a Pap test), and knowledge among immigrant Hispanic/Latina women from farmworker backgrounds. These women are disproportionately burdened with cervical cancer, with mortality rates significantly higher than non-Hispanic whites. The two-arm, quasi-experimental study was conducted in four rural counties of Southeast Georgia in 2014-2015. Hispanic/Latina immigrant women aged 21-65 years and overdue for a Pap test were included as intervention (N = 38) and control (N = 52) group participants. The intervention was developed in partnership with a group of promotoras to create the toolkit of materials which includes a curriculum guide, a brochure, a flipchart, a short animated video, and in-class activities. Twelve (32 %) intervention group participants received the Pap test compared to 10 (19 %) control group participants (p = 0.178). The intervention group scored significantly higher on both cervical cancer knowledge recall and retention than the control group (p < 0.001). While there was no statistically significant difference in cervical cancer screening self-efficacy scores between the group participants, both groups scored higher at follow-up, adjusting for the baseline scores. The group intervention approach was associated with increased cervical cancer knowledge but not uptake of Pap test. More intensive interventions using patient navigation approaches or promotoras who actively follow participants or conducting one-on-one rather than group sessions may be needed to achieve improved screening outcomes with this population.
Cognitive impairment in heart failure: issues of measurement and etiology.
Riegel, Barbara; Bennett, Jill A; Davis, Andra; Carlson, Beverly; Montague, John; Robin, Howard; Glaser, Dale
2002-11-01
Clinicians need easy methods of screening for cognitive impairment in patients with heart failure. If correlates of cognitive impairment could be identified, more patients with early cognitive impairment could be treated before the problem interfered with adherence to treatment. To describe cognitive impairment in patients with heart failure, to explore the usefulness of 4 measures of cognitive impairment, and to assess correlates of cognitive impairment. A descriptive, correlational design was used. Four screening measures of cognition were assessed in 42 patients with heart failure: Commands subtest and Complex Ideational Material subtest of the Boston Diagnostic Aphasia Examination, Mini-Mental State Examination, and Draw-a-Clock Test. Cognitive impairment was defined as performance less than the standardized (T-score) cutoff point on at least 1 of the 4 measures. Possible correlates of cognitive impairment included age, education, hypotension, fluid overload (serum osmolality < 269 mOsm/kg), and dehydration (serum osmolality > or = 295 mOsm/kg). Cognitive impairment was detected in 12 (28.6%) of 42 participants. The 4 screening tests varied in effectiveness, but the Draw-a-Clock Test indicated impairment in 50% of the 12 impaired patients. A summed standardized score for the 4 measures was not significantly associated with age, education, hypotension, fluid overload, or dehydration in this sample. Cognitive impairment is relatively common in patients with heart failure. The Draw-a-Clock Test was most useful in detecting cognitive impairment, although it cannot be used to detect problems with verbal learning or delayed recall and should not be used as the sole screening method for patients with heart failure. Correlates of cognitive impairment require further study.
NASA Astrophysics Data System (ADS)
Moreno, Roxana Arleen
The present dissertation tested the hypothesis that software pedagogical agents can promote constructivist learning in a discovery-based multimedia environment. In a preliminary study, students who received a computer-based lesson on environmental science performed better on subsequent tests of problem solving and motivation when they learned with the mediation of a fictional agent compared to when they learned the same material from text. In order to investigate further the basis for this personal agent effect, I varied whether the agent's words were presented as speech or on-screen text and whether or not the agent's image appeared on the screen. Both with a fictional agent (Experiment 1) and a video of a human face (Experiment 2), students performed better on tests of retention, problem-solving transfer, and program ratings when words were presented as speech rather than on-screen text (producing a modality effect) but visual presence of the agent did not affect test performance (producing no image effect). Next, I varied whether or not the agent's words were presented in conversational style (i.e., as dialogue) or formal style (i.e., as monologue) both using speech (Experiment 3) and on-screen text (Experiment 4). In both experiments, there was a dialogue effect in which conversational-style produced better retention and transfer performance. Students who learned with conversational-style text rated the program more favorably than those who learned with monologue-style text. The results support cognitive principles of multimedia learning which underlie the understanding of a computer lesson about a complex scientific system.
Pichini, Simona; Gottardi, Massimo; Marchei, Emilia; Svaizer, Fiorenza; Pellegrini, Manuela; Rotolo, Maria Concetta; Algar, Oscar García; Pacifici, Roberta
2014-05-01
Drug testing in hair is a unique analysis in pharmacotoxicology for establishing a past repeated history of consumption or passive exposure to psychotropic substances. A rather lengthy sample treatment is usually required before parent drugs and eventual metabolites are amenable to quali-quantitative analysis. We evaluated a high throughput screening and confirmation analysis of drugs of abuse in hair by immunoassay and a validated ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) after applying a rapid digestion of the keratin matrix with VMA-T reagent before screening assay and M3 reagent before confirmatory analysis. Samples digestion with VMA-T reagent and immunometric screening analysis of hair calibrators, controls and clinical samples for a total of 150 samples was completed in 4 h. No false-positive and -negative results were found for the control material. UPLC-MS/MS analysis confirmed all of the 31 adult hair samples positive to the screening test using internationally established cut-offs, and identified and quantified drugs of abuse in 32 pediatric hair samples, applying lower limits of quantification from 0.01 to 0.1 ng analyte per mg hair. Analytical recovery was between 70.9% and 100.7%. Intra- and inter-assay imprecision and inaccuracy were always lower than 10%. Rapid extraction, identification and quantification of drugs of abuse in hair by immunoassay and UPLC-MS/MS was tested for its feasibility in clinical samples and provided excellent results for rapid and effective drug testing in hair in epidemiological studies.
Creep-fatigue life prediction for engine hot section materials (isotropic)
NASA Technical Reports Server (NTRS)
Moreno, V.
1982-01-01
The objectives of this program are the investigation of fundamental approaches to high temperature crack initiation life prediction, identification of specific modeling strategies and the development of specific models for component relevant loading conditions. A survey of the hot section material/coating systems used throughout the gas turbine industry is included. Two material/coating systems will be identified for the program. The material/coating system designated as the base system shall be used throughout Tasks 1-12. The alternate material/coating system will be used only in Task 12 for further evaluation of the models developed on the base material. In Task II, candidate life prediction approaches will be screened based on a set of criteria that includes experience of the approaches within the literature, correlation with isothermal data generated on the base material, and judgements relative to the applicability of the approach for the complex cycles to be considered in the option program. The two most promising approaches will be identified. Task 3 further evaluates the best approach using additional base material fatigue testing including verification tests. Task 4 consists of technical, schedular, financial and all other reporting requirements in accordance with the Reports of Work clause.
Bang, Hae In; Jang, Mi Ae; Lee, Yong Wha
2017-11-01
The demand for rapid and broad clinical toxicology screens is on the rise. Recently, a new rapid toxicology screening test, the Triage TOX Drug Screen (Alere Inc., USA), which can simultaneously detect 11 drugs of abuse and therapeutic drugs with an instrument-read cartridge, was developed. In the present study, we evaluated the efficacy of this new on-site immunoassay using 105 urine specimens; the results were compared with those obtained by using ultra-performance liquid chromatography with tandem mass spectrometry (UPLC-TMS). Precision was evaluated according to the CLSI EP12-A2 for analyte concentrations near the cutoff, including C₅₀ and±30% of C₅₀, for each drug using standard materials. The C₅₀ specimens yielded 35-65% positive results and the±30% concentration range of all evaluated drugs encompassed the C₅-C₉₅ interval. The overall percent agreement of the Triage TOX Drug Screen was 92.4-100% compared with UPLC-TMS; however, the Triage TOX Drug Screen results showed some discordant cases including acetaminophen, amphetamine, benzodiazepine, opiates, and tricyclic antidepressants. The overall performance of the Triage TOX Drug Screen assay was comparable to that of UPLC-TMS for screening of drug intoxication in hospitals. This assay could constitute a useful screening method for drugs of abuse and therapeutic drugs in urine. © The Korean Society for Laboratory Medicine.
Cancer Screening Test Use - United States, 2015.
White, Arica; Thompson, Trevor D; White, Mary C; Sabatino, Susan A; de Moor, Janet; Doria-Rose, Paul V; Geiger, Ann M; Richardson, Lisa C
2017-03-03
Healthy People 2020 (HP2020) includes objectives to increase screening for breast, cervical, and colorectal cancer (1) as recommended by the U.S. Preventive Services Task Force (USPSTF).* Progress toward meeting these objectives is monitored by measuring cancer screening test use against national targets using data from the National Health Interview Survey (NHIS) (1). Analysis of 2015 NHIS data indicated that screening test use remains substantially below HP2020 targets for selected cancer screening tests. Although colorectal cancer screening test use increased from 2000 to 2015, no improvements in test use were observed for breast and cervical cancer screening. Disparities exist in screening test use by race/ethnicity, socioeconomic status, and health care access indicators. Increased measures to implement evidence-based interventions and conduct targeted outreach are needed if the HP2020 targets for cancer screening are to be achieved and the disparities in screening test use are to be reduced.
Huber, Ingrid; Block, Annette; Sebah, Daniela; Debode, Frédéric; Morisset, Dany; Grohmann, Lutz; Berben, Gilbert; Stebih, Dejan; Milavec, Mojca; Zel, Jana; Busch, Ulrich
2013-10-30
Worldwide, qualitative methods based on PCR are most commonly used as screening tools for genetically modified material in food and feed. However, the increasing number and diversity of genetically modified organisms (GMO) require effective methods for simultaneously detecting several genetic elements marking the presence of transgenic events. Herein we describe the development and validation of a pentaplex, as well as complementary triplex and duplex real-time PCR assays, for the detection of the most common screening elements found in commercialized GMOs: P-35S, T-nos, ctp2-cp4-epsps, bar, and pat. The use of these screening assays allows the coverage of many GMO events globally approved for commercialization. Each multiplex real-time PCR assay shows high specificity and sensitivity with an absolute limit of detection below 20 copies for the targeted sequences. We demonstrate by intra- and interlaboratory tests that the assays are robust as well as cost- and time-effective for GMO screening if applied in routine GMO analysis.
Fu, Wei; Wei, Shuang; Wang, Chenguang; Du, Zhixin; Zhu, Pengyu; Wu, Xiyang; Wu, Gang; Zhu, Shuifang
2017-08-15
High throughput screening systems are the preferred solution to meet the urgent requirement of increasing number of genetically modified organisms (GMOs). In this study, we have successfully developed a multiplex GMO element screening system with dual priming oligonucleotide (DPO) primers. This system can detect the cauliflower mosaic virus 35S (CaMV 35S), terminator of nopaline synthase gene (NOS), figwort mosaic virus 35S (FMV 35S) promoter, neomycin phosphotransferaseII (NPTII), Bt Cry 1Ab, phosphinothricin acetyltransferase genes (bar) and Streptomyces viridochromogenes (pat) simultaneously, which covers more than 90% of all authorized GMO species worldwide. This system exhibits a high tolerance to annealing temperatures, high specificity and a limit of detection equal to conventional PCR. A total of 214 samples from markets, national entry-exit agencies, the Institute for Reference Materials and Measurement (IRMM) and the American Oil Chemists' Society (AOCS) were also tested for applicability. This screening system is therefore suitable for GMO screening. Copyright © 2017 Elsevier Ltd. All rights reserved.
Baldwin, C A; Beaulieu, H J; Buchan, R M; Johnson, H H
1982-01-01
Forty-one public schools in Colorado were drawn at random and surveyed for asbestos-containing materials. After bulk samples of possible asbestos materials from the schools were collected and analyzed, the K2 asbestos screening test was used to eliminate samples that did not contain asbestos. Samples with positive results on the K2 test were analyzed by an outside laboratory by polarized light microscopy. The risk of potential exposure presented by these materials was then assessed for each site from which a sample was taken. Of 113 samples collected, results were negative for asbestos for only 10.6 percent by the K2 test. Of the 101 samples for which results were positive, 56 actually contained 1 or more forms of asbestos. Twelve of these 56 samples were from sprayed material; the remaining 44 were from other materials containing asbestos. Of the 41 schools sampled, 31 had asbestos materials in one of more locations. The potential exposure values for these materials ranged from very low to very high, but the majority had high-exposure potentials. Estimates based on the survey of the 41 schools indicated that 63 to 89 percent of the public schools in Colorado have asbestos materials that present potentially serious hazards, not only to the children, teachers, and staff, but also to members of the community who use the school buildings after regular school hours.
Evaluation of the laboratory mouse model for screening topical mosquito repellents.
Rutledge, L C; Gupta, R K; Wirtz, R A; Buescher, M D
1994-12-01
Eight commercial repellents were tested against Aedes aegypti 0 and 4 h after application in serial dilution to volunteers and laboratory mice. Results were analyzed by multiple regression of percentage of biting (probit scale) on dose (logarithmic scale) and time. Empirical correction terms for conversion of values obtained in tests on mice to values expected in tests on human volunteers were calculated from data obtained on 4 repellents and evaluated with data obtained on 4 others. Corrected values from tests on mice did not differ significantly from values obtained in tests on volunteers. Test materials used in the study were dimethyl phthalate, butopyronoxyl, butoxy polypropylene glycol, MGK Repellent 11, deet, ethyl hexanediol, Citronyl, and dibutyl phthalate.
Property Screening and Evaluation of Ceramic Turbine Materials
1984-04-01
Unless otherwise indicated, the upper and lower spans were 0.875 and 1.750 in., respectively. For room-temperature tests, a stainless steel fixture...Silicon Nitride High Temperature Properties Silicon Carbide Silicon Ceramics Transformation-Toughened Zirconia Structural Ceramics Mechanical Properties...3ilicon carbide and silicon nitride, that have potential as structural components in"advanced gas turbine engines, were evaluated. Thermal and
A Smartphone App to Screen for HIV-Related Neurocognitive Impairment.
Robbins, Reuben N; Brown, Henry; Ehlers, Andries; Joska, John A; Thomas, Kevin G F; Burgess, Rhonda; Byrd, Desiree; Morgello, Susan
2014-02-01
Neurocognitive Impairment (NCI) is one of the most common complications of HIV-infection, and has serious medical and functional consequences. However, screening for it is not routine and NCI often goes undiagnosed. Screening for NCI in HIV disease faces numerous challenges, such as limited screening tests, the need for specialized equipment and apparatuses, and highly trained personnel to administer, score and interpret screening tests. To address these challenges, we developed a novel smartphone-based screening tool, NeuroScreen , to detect HIV-related NCI that includes an easy-to-use graphical user interface with ten highly automated neuropsychological tests. To examine NeuroScreen's : 1) acceptability among patients and different potential users; 2) test construct and criterion validity; and 3) sensitivity and specificity to detect NCI. Fifty HIV+ individuals were administered a gold-standard neuropsychological test battery, designed to detect HIV-related NCI, and NeuroScreen . HIV+ test participants and eight potential provider-users of NeuroScreen were asked about its acceptability. There was a high level of acceptability of NeuroScreen by patients and potential provider-users. Moderate to high correlations between individual NeuroScreen tests and paper-and-pencil tests assessing the same cognitive domains were observed. NeuroScreen also demonstrated high sensitivity to detect NCI. NeuroScreen, a highly automated, easy-to-use smartphone-based screening test to detect NCI among HIV patients and usable by a range of healthcare personnel could help make routine screening for HIV-related NCI feasible. While NeuroScreen demonstrated robust psychometric properties and acceptability, further testing with larger and less neurocognitively impaired samples is warranted.
Use of unbalanced laminates as a screening method for microcracking
NASA Technical Reports Server (NTRS)
Papadopoulos, Demetrios S.; Bowles, Kenneth J.
1990-01-01
State-of-the-art, high temperature polyimide matrix composites, reinforced with continuous graphite fibers are known to be susceptible to intraply cracking when thermally cycled over their useful service temperature range. It is believed that the transply cracking, in part, results from residual stresses caused by differences in coefficients of thermal expansion (CTE) between the polymer matrix and the reinforcement. Thermal cycling tests to investigate this phenomenon involve expensive time and energy consuming programs which are not economically feasible for use as a part of a materials screening process. As an alternative to thermal cycling studies, a study of unbalanced crossply graphite fiber reinforcement composites was conducted to assess the effect of the composite ply layup and surface condition on the residual stresses that remain after the processing of these materials. The residual stresses were assessed by measuring the radii of curvature of the types of laminates that were studied. The temperature at which stress-free conditions existed were determined and a dye penetrant method was used to observe surface damage resulting from excessive residual stress buildup. These results are compared with some published results of thermal cycling tests that were previously conducted on balanced polyimide composites.
Evaluation of Indoor Air Quality Screening Strategies: A Step-Wise Approach for IAQ Screening.
Wong, Ling-Tim; Mui, Kwok-Wai; Tsang, Tsz-Wun
2016-12-14
Conducting a full indoor air quality (IAQ) assessment in air-conditioned offices requires large-scale material and manpower resources. However, an IAQ index can be adopted as a handy screening tool to identify any premises (with poor IAQ) that need more comprehensive IAQ assessments to prioritize IAQ improvements. This study proposes a step-wise IAQ screening protocol to facilitate its cost-effective management among building owners and managers. The effectiveness of three IAQ indices, namely θ₁ (with one parameter: CO₂), θ₂ (with two parameters: CO₂ and respirable suspended particulates, RSP) and θ₃ (with three parameters: CO₂, RSP, and total volatile organic compounds, TVOC) are evaluated. Compared in a pairwise manner with respect to the minimum satisfaction levels as stated in the IAQ Certification Scheme by the Hong Kong Environmental Protection Department, the results show that a screening test with more surrogate IAQ parameters is good at identifying both lower and higher risk groups for unsatisfactory IAQ, and thus offers higher resolution. Through the sensitivity and specificity for identifying IAQ problems, the effectiveness of alternative IAQ screening methods with different monitoring parameters is also reported.
Evaluation of Indoor Air Quality Screening Strategies: A Step-Wise Approach for IAQ Screening
Wong, Ling-tim; Mui, Kwok-wai; Tsang, Tsz-wun
2016-01-01
Conducting a full indoor air quality (IAQ) assessment in air-conditioned offices requires large-scale material and manpower resources. However, an IAQ index can be adopted as a handy screening tool to identify any premises (with poor IAQ) that need more comprehensive IAQ assessments to prioritize IAQ improvements. This study proposes a step-wise IAQ screening protocol to facilitate its cost-effective management among building owners and managers. The effectiveness of three IAQ indices, namely θ1 (with one parameter: CO2), θ2 (with two parameters: CO2 and respirable suspended particulates, RSP) and θ3 (with three parameters: CO2, RSP, and total volatile organic compounds, TVOC) are evaluated. Compared in a pairwise manner with respect to the minimum satisfaction levels as stated in the IAQ Certification Scheme by the Hong Kong Environmental Protection Department, the results show that a screening test with more surrogate IAQ parameters is good at identifying both lower and higher risk groups for unsatisfactory IAQ, and thus offers higher resolution. Through the sensitivity and specificity for identifying IAQ problems, the effectiveness of alternative IAQ screening methods with different monitoring parameters is also reported. PMID:27983667
Semiautomated TaqMan PCR screening of GMO labelled samples for (unauthorised) GMOs.
Scholtens, Ingrid M J; Molenaar, Bonnie; van Hoof, Richard A; Zaaijer, Stephanie; Prins, Theo W; Kok, Esther J
2017-06-01
In most countries, systems are in place to analyse food products for the potential presence of genetically modified organisms (GMOs), to enforce labelling requirements and to screen for the potential presence of unauthorised GMOs. With the growing number of GMOs on the world market, a larger diversity of methods is required for informative analyses. In this paper, the specificity of an extended screening set consisting of 32 screening methods to identify different crop species (endogenous genes) and GMO elements was verified against 59 different GMO reference materials. In addition, a cost- and time-efficient strategy for DNA isolation, screening and identification is presented. A module for semiautomated analysis of the screening results and planning of subsequent event-specific tests for identification has been developed. The Excel-based module contains information on the experimentally verified specificity of the element methods and of the EU authorisation status of the GMO events. If a detected GMO element cannot be explained by any of the events as identified in the same sample, this may indicate the presence of an unknown unauthorised GMO that may not yet have been assessed for its safety for humans, animals or the environment.
ERIC Educational Resources Information Center
Hsu, Jenq-Muh; Chang, Ting-Wen; Yu, Pao-Ta
2012-01-01
The teaching and learning environment in a traditional classroom typically includes a projection screen, a projector, and a computer within a digital interactive table. Instructors may apply multimedia learning materials using various information communication technologies to increase interaction effects. However, a single screen only displays a…
NASA Astrophysics Data System (ADS)
Jusman, Yessi; Ng, Siew-Cheok; Hasikin, Khairunnisa; Kurnia, Rahmadi; Osman, Noor Azuan Bin Abu; Teoh, Kean Hooi
2016-10-01
The capability of field emission scanning electron microscopy and energy dispersive x-ray spectroscopy (FE-SEM/EDX) to scan material structures at the microlevel and characterize the material with its elemental properties has inspired this research, which has developed an FE-SEM/EDX-based cervical cancer screening system. The developed computer-aided screening system consisted of two parts, which were the automatic features of extraction and classification. For the automatic features extraction algorithm, the image and spectra of cervical cells features extraction algorithm for extracting the discriminant features of FE-SEM/EDX data was introduced. The system automatically extracted two types of features based on FE-SEM/EDX images and FE-SEM/EDX spectra. Textural features were extracted from the FE-SEM/EDX image using a gray level co-occurrence matrix technique, while the FE-SEM/EDX spectra features were calculated based on peak heights and corrected area under the peaks using an algorithm. A discriminant analysis technique was employed to predict the cervical precancerous stage into three classes: normal, low-grade intraepithelial squamous lesion (LSIL), and high-grade intraepithelial squamous lesion (HSIL). The capability of the developed screening system was tested using 700 FE-SEM/EDX spectra (300 normal, 200 LSIL, and 200 HSIL cases). The accuracy, sensitivity, and specificity performances were 98.2%, 99.0%, and 98.0%, respectively.
Nehnevajova, Erika; Herzig, Rolf; Federer, Guido; Erismann, Karl-Hans; Schwitzguébel, Jean-Paul
2005-01-01
Sunflower can be used for the remediation of metal-contaminated soils. Its high biomass production makes this plant species interestingfor phytoextraction and using sunflower oil for a technical purpose may improve the economic balance of phytoremediation. The aim of the present field study was to screen 15 commercial cultivars of Helianthus annuus L. grown on metal-contaminated soil, to find out the variety with the highest metal extraction, which can be further improved by mutation or in vitro breeding procedures. Two different fertilizers (ammonium sulphate and ammonium nitrate) were also used to enhance the bioavailability of metals in soil Highly significant differences were observed within tested varieties for metal accumulation and extraction efficiency. Furthermore, ammonium nitrate increased cadmium extraction, whereas ammonium sulphate enhanced zinc and lead uptake in most tested cultivars. In this field-based sunflower screening, we found enhanced cumulative Cd, Zn, and Pb extraction efficiency by a factor 4.4 for Salut cultivar. We therefore emphasize that prior to any classical breeding or genetic engineering enhancing metal uptake potential, a careful screening of various genotypes should be done to select the cultivar with the naturally highest metal uptake and to start the genetic improvement with the best available plant material.
Taking transgenic rice drought screening to the field.
Gaudin, Amélie C M; Henry, Amelia; Sparks, Adam H; Slamet-Loedin, Inez H
2013-01-01
Numerous transgenes have been reported to increase rice drought resistance, mostly in small-scale experiments under vegetative-stage drought stress, but few studies have included grain yield or field evaluations. Different definitions of drought resistance are currently in use for field-based and laboratory evaluations of transgenics, the former emphasizing plant responses that may not be linked to yield under drought. Although those fundamental studies use efficient protocols to uncover and validate gene functions, screening conditions differ greatly from field drought environments where the onset of drought stress symptoms is slow (2-3 weeks). Simplified screening methods, including severely stressed survival studies, are therefore not likely to identify transgenic events with better yield performance under drought in the target environment. As biosafety regulations are becoming established to allow field trials in some rice-producing countries, there is a need to develop relevant screening procedures that scale from preliminary event selection to greenhouse and field trials. Multilocation testing in a range of drought environments may reveal that different transgenes are necessary for different types of drought-prone field conditions. We describe here a pipeline to improve the selection efficiency and reproducibility of results across drought treatments and test the potential of transgenic rice for the development of drought-resistant material for agricultural purposes.
Gazsi, Claudia C; Oriel, Kathryn N
2010-01-01
A goal when designing the Physical Therapy Program at Lebanon Valley College (LVC) was to maximize vertical and horizontal integration of course content related to (a) medical Spanish, (b) geriatrics, and (c) health promotion through a service learning engagement. Seventeen Doctor of Physical Therapy students from LVC participated in a fall risk screening at a local senior center in a Spanish-speaking neighborhood. The screen included the single leg stance, timed-up-and-go (TUG), and functional reach tests. The students screened 30 participants over a 3-hour time period. Following the screening event, students were asked to reflect on their experience. Reflections revealed that the activity supported integration of concurrent didactic course material and Core Values, reinforced cultural issues presented the previous year, and convinced students that physical therapists have a distinct and important role in primary and secondary prevention in meeting the needs of the Spanish-speaking elderly community.
Maxwell, Annette E.; Wang, Judy H.; Young, Lucy; Crespi, Catherine M.; Mistry, Ritesh; Sudan, Madhuri; Bastani, Roshan
2010-01-01
This study evaluated the feasibility, acceptability and potential effect of a small-group video intervention led by trained Chinese American lay educators who recruited Chinese American women not up to date on mammography screening. Nine lay educators conducted 14 “breast health tea time workshops” in community settings and private homes that started with watching a culturally tailored video promoting screening followed by a question and answer session and distribution of print materials. Many group attendees did not have health insurance or a regular doctor, had low levels of income and were not proficient in English. Forty-four percent of the attendees reported receipt of a mammogram within 6 months after the small-group session with higher odds of screening among women who had lived in the U.S. less than 10% of their lifetime. Four of the educators were very interested in conducting another group session in the next 6 months. PMID:20720095
Screen Cage Ion Plating (SCIP) and scratch testing of polycrystalline aluminum oxide
NASA Technical Reports Server (NTRS)
Spalvins, Talivaldis; Sliney, Harold E.; Deadmore, Daniel L.
1992-01-01
A screen cage ion plating (SCIP) technique was developed to apply silver films on electrically nonconducting aluminum oxide. It is shown that SCIP has remarkable throwing power; surfaces to be coated need not be in direct line of sight with the evaporation source. Scratch tests, employing a diamond stylus with a 200 micro m radius tip, were performed on uncoated and on silver coated alumina. Subsequent surface analysis show that a significant amount of silver remains on the scratched surfaces, even in areas where high stylus load produced severe crack patterns in the ceramic. Friction coefficients were lowered during the scratch tests on the coated alumina indicating that this modification of the ion planting process should be useful for applying lubricating films of soft metals to electrical insulating materials. The very good throwing power of SCIP also strongly suggests general applicability of this process in other areas of technology, e.g., electronics, in addition to tribology.
Zmurko, Joanna; Vasey, Douglas B; Donald, Claire L; Armstrong, Alison A; McKee, Marian L; Kohl, Alain; Clayton, Reginald F
2018-02-01
Ensuring the virological safety of biologicals is challenging due to the risk of viral contamination of raw materials and cell banks, and exposure during in-process handling to known and/or emerging viral pathogens. Viruses may contaminate raw materials and biologicals intended for human or veterinary use and remain undetected until appropriate testing measures are employed. The outbreak and expansive spread of the mosquito-borne flavivirus Zika virus (ZIKV) poses challenges to screening human- and animal -derived products used in the manufacture of biologicals. Here, we report the results of an in vitro study where detector cell lines were challenged with African and Asian lineages of ZIKV. We demonstrate that this pathogen is robustly detectable by in vitro assay, thereby providing assurance of detection of ZIKV, and in turn underpinning the robustness of in vitro virology assays in safety testing of biologicals.
How to report and interpret screening test properties: guidelines for driving researchers.
Weaver, Bruce; Walter, Stephen D; Bédard, Michel
2014-01-01
One important goal of driving research is the development of a short but valid office-based screening test for fitness to drive of aging drivers. Several candidate tests have been proposed already, and no doubt others will be proposed in the future. It might seem obvious that authors advocating for the adoption of a particular screening test or procedure should report sensitivity, specificity, and other common screening test properties. Unfortunately, driving researchers have frequently failed to report any screening test properties. Others have reported screening test properties but have made basic mistakes such as calculating predictive values of positive and negative tests but reporting them incorrectly as sensitivity and specificity. These omissions and errors suggest that some driving researchers may be unaware of the importance of accurately reporting test properties when proposing a screening procedure and that others may need a refresher on how to calculate and interpret the most common screening test properties. Many good learning resources for screening and diagnostic tests are available, but most of them are intended for students and researchers in medicine, epidemiology, or public health. We hope that this tutorial in a prominent transportation journal will help lead to improved reporting and interpretation of screening test properties in articles that assess the usefulness of potential screening tools for fitness to drive.
Study of thermal insulation for airborne liquid hydrogen fuel tanks
NASA Technical Reports Server (NTRS)
Ruccia, F. E.; Lindstrom, R. S.; Lucas, R. M.
1978-01-01
A concept for a fail-safe thermal protection system was developed. From screening tests, approximately 30 foams, adhesives, and reinforcing fibers using 0.3-meter square liquid nitrogen cold plate, CPR 452 and Stafoam AA1602, both reinforced with 10 percent by weight of 1/16 inch milled OCF Style 701 Fiberglas, were selected for further tests. Cyclic tests with these materials in 2-inch thicknesses bonded on a 0.6-meter square cold plate with Crest 7410 adhesive systems, were successful. Zero permeability gas barriers were identified and found to be compatible with the insulating concept.
Trends in cancer screening among Hispanic and white non-Hispanic women, 2000-2005.
Zhou, Jing; Enewold, Lindsey; Peoples, George E; Clifton, Guy T; Potter, John F; Stojadinovic, Alexander; Zhu, Kangmin
2010-12-01
Hispanics are the largest and fastest growing ethnic group in the United States. Compared with white non-Hispanic women, however, Hispanic women have significantly lower cancer screening rates. Programs designed to increase cancer screening rates, including the national Screen for Life campaign, which specifically promoted colorectal cancer (CRC) screening, regional educational/research programs, and state cancer control programs, have been launched. Screen for Life and some of these other intervention programs have targeted Hispanic populations by providing educational materials in Spanish in addition to English. The objective of this study was to compare changes in colorectal, breast, and cervical cancer screening rates from 2000 to 2005 among Hispanic and white non-Hispanic women, using data from the National Health Interview Survey (NHIS). The age ranges of study subjects and the definitions of cancer screening were site specific and based on the American Cancer Society (ACS) screening recommendations. Although overall screening rates were found to be lower among Hispanic women, CRC screening increased about 1.5-fold among both Hispanic and white non-Hispanic women, mainly driven by endoscopic screening, which increased 2.1-fold and 2.9-fold, respectively, from 2000 to 2005 (p < 0.01). Fecal occult blood testing (FOBT) for CRC declined among white non-Hispanic women and remained stable among Hispanic women during the same period. Mammogram and Pap smear screening tended to decline during the study period for both ethnic groups, especially white non-Hispanic women. Although cancer screening rates may be affected by multiple factors, culturally sensitive and linguistically appropriate national educational programs may have contributed to the increase in endoscopic CRC screening compliance.
Screening for cervical cancer in imprisoned women in Brazil
de Souza, Albert Schiaveto; de Souza, Taiana Gabriela Barbosa; Tsuha, Daniel Henrique; Barbieri, Ana Rita
2017-01-01
Context and objective Incarcerated women are more vulnerable to developing cervical cancer than women in general; therefore, screening and intervention programs must be included in their healthcare provision. We therefore aimed to investigate the state of cervical cancer screening for imprisoned women in Mato Grosso do Sul, and to analyze the interventions geared toward the control of cervical cancer. Materials and methods This was a cross-sectional study with analysis of primary and secondary data. Interviews were held with 510 women in seven prisons in the Brazilian state of Mato Grosso do Sul. The data for 352 medical records were analyzed statistically with the significance level set at 5%. Associations were assessed by the chi-squared test, adjusted by the Bonferroni correction. Results Most female prisoners had limited education, used tobacco, and had key risk factors for the development of cervical cancer. Half of the women interviewed (n = 255) stated that they had received a Papanicolaou (Pap) test in prison, but 134 (52.5%) of these did not know the result. Of those who had not received a Pap test, 149 (58.4%) stated that this was because of a lack of opportunity. There was no information regarding the provision of Pap tests or subsequent treatment in the medical records of 211 (59.9%) women. No protocols were in place for the provision of Pap tests in prison. There were statistical differences between prisons in terms of test frequency, the information provided to women, and how information was recorded in medical records. Conclusion The screening of cervical cancer in prisons is neither systematic nor regular, and the results are not communicated to women in a significant number of cases. It is necessary to organize health services within the prison environment, ensuring that tests are done and that there is investigation for human papillomavirus. This could increase the diagnosis of cervical cancer at less advanced stages of the disease. PMID:29252994
Jiang, Jianwen; Babarao, Ravichandar; Hu, Zhongqiao
2011-07-01
Nanoporous materials have widespread applications in chemical industry, but the pathway from laboratory synthesis and testing to practical utilization of nanoporous materials is substantially challenging and requires fundamental understanding from the bottom up. With ever-growing computational resources, molecular simulations have become an indispensable tool for material characterization, screening and design. This tutorial review summarizes the recent simulation studies in zeolites, metal-organic frameworks and protein crystals, and provides a molecular overview for energy, environmental and pharmaceutical applications of nanoporous materials with increasing degree of complexity in building blocks. It is demonstrated that molecular-level studies can bridge the gap between physical and engineering sciences, unravel microscopic insights that are otherwise experimentally inaccessible, and assist in the rational design of new materials. The review is concluded with major challenges in future simulation exploration of novel nanoporous materials for emerging applications.
Feasibility of a super high energy density battery of the Li/BrF3 electrochemical system
NASA Astrophysics Data System (ADS)
Pyszczek, Michael F.; Ebel, Steven J.; Frysz, Christine A.
To date, design and construction of a material handling and measurement system along with the apparatus required for waste material disposal has been completed. Preliminary corrosion screening of potential case materials is currently underway. A review of the literature, has led to the use of Monel (trademark) 400 as the material of construction for the handling and measurement system. The inherent stability of this material with bromine trifluoride in its liquid state is crucial to ensure that contamination does not occur during storage and handling. For applications which require a flexible or transparent material, items fabricated from perfluoroalkyoxy polymers (Teflon (trademark) PFA) were utilized. One such application encountered was in the design of the graduated tank which allows visual inspection of the material prior to dispensing. Containers used for compatibility/corrosion testing were also constructed of PFA.
Trials and projects on cervical cancer and human papillomavirus prevention in sub-Saharan Africa.
Adefuye, Peter O; Broutet, Nathalie J; de Sanjosé, Silvia; Denny, Lynette A
2013-12-29
Cervical cancer is the leading cause of cancer morbidity and mortality in women in sub-Saharan Africa (SSA), accounting for about 50,000 deaths annually. Until recently, cytology was the gold standard for screening and prevention of cervical cancer. This method of screening has not been successful in SSA due to a lack of human, financial and material resources and poor health care infrastructure. It is estimated that less than 5% of at risk women have ever being screened. In the past two decades alternative approaches to cytology for cervical cancer screening have been evaluated in low- and medium-income countries. Visual inspection with acetic acid (VIA) and/or Lugol's iodine (VILI) have been shown to have adequate sensitivity, although low specificity, in a number of cross-sectional research and demonstration projects. Visual inspection methods require minimal resources, are technologically accessible, and are feasible for screening for precancerous lesions. Linking screening with VIA/VILI to treatment with cryotherapy may enable screening and treatment to take place in one visit, but this is likely to result in large numbers of women being subjected to unnecessary treatment. A number of studies have shown that cryotherapy is not associated with significant side effects or complications and is well tolerated. Creating the infrastructure for screening of older women is considered desirable, despite the limitations of visual inspection methods as screening tests. Understanding the role of human papillomavirus (HPV) infection in the etiology of cervical cancer and the discovery of HPV rapid test kits, as well as the development of vaccines against the HPV oncogenic types, have created new opportunities for prevention of cervical cancer. Trials and projects have established (and are still ongoing) the feasibility of using these molecular tests for screening. The ultimate in prevention method is primary prevention, offered by the advent of prophylactic vaccines against the most important oncogenic types, namely HPV16 and 18. This article forms part of a regional report entitled "Comprehensive Control of HPV Infections and Related Diseases in the Sub-Saharan Africa Region" Vaccine Volume 31, Supplement 5, 2013. Updates of the progress in the field are presented in a separate monograph entitled "Comprehensive Control of HPV Infections and Related Diseases" Vaccine Volume 30, Supplement 5, 2012. Copyright © 2012 Elsevier Ltd. All rights reserved.
Araia, Makda H; Potter, Beth K
2011-09-01
The Internet is a potentially important medium for communication about public health programs including newborn screening. This study explores whether the information available on official newborn screening program websites is consistent with existing guidelines regarding educational content for parents. We conducted a systematic search of the public websites of newborn screening programs in the US and Canada, identifying web pages and downloadable brochures that contained educational information. Two researchers independently reviewed all documents to determine the extent to which they included 14 key recommended educational messages. We identified 85 documents containing educational information on 46 US and 6 Canadian newborn screening program websites. The documents contained from 1 to 14 of the recommended messages. The majority of identified materials emphasized the importance and benefits of screening. The differences between US and Canadian materials were related to the importance of parental involvement in follow-up and issues of consent and storage of blood spots. Our findings are consistent with studies of non-web-based newborn screening education materials. The results emphasize the need for further evaluation of newborn screening education, including internet-based resources, particularly in terms of the impact of particular messages on parental attitudes and behaviors.
Promoting chlamydia screening with posters and leaflets in general practice--a qualitative study.
Freeman, Elaine; Howell-Jones, Rebecca; Oliver, Isabel; Randall, Sarah; Ford-Young, William; Beckwith, Philippa; McNulty, Cliodna
2009-10-12
General practice staff are reluctant to discuss sexual health opportunistically in all consultations. Health promotion materials may help alleviate this barrier. Chlamydia screening promotion posters and leaflets, produced by the English National Chlamydia Screening Programme (NCSP), have been available to general practices, through local chlamydia screening offices, since its launch. In this study we explored the attitudes of general practice staff to these screening promotional materials, how they used them, and explored other promotional strategies to encourage chlamydia screening. Twenty-five general practices with a range of screening rates, were purposively selected from six NCSP areas in England. In focus groups doctors, nurses, administrative staff and receptionists were encouraged to discuss candidly their experiences about their use and opinions of posters, leaflets and advertising to promote chlamydia screening. Researchers observed whether posters and leaflets were on display in reception and/or waiting areas. Data were collected and analysed concurrently using a stepwise framework analytical approach. Although two-thirds of screening practices reported that they displayed posters and leaflets, they were not prominently displayed in most practices. Only a minority of practices reported actively using screening promotional materials on an ongoing basis. Most staff in all practices were not following up the advertising in posters and leaflets by routinely offering opportunistic screening to their target population. Some staff in many practices thought posters and leaflets would cause offence or embarrassment to their patients. Distribution of chlamydia leaflets by receptionists was thought to be inappropriate by some practices, as they thought patients would be offended when being offered a leaflet in a public area. Practice staff suggested the development of pocket-sized leaflets. The NCSP should consider developing a range of more discrete but eye catching posters and small leaflets specifically to promote chlamydia screening in different scenarios within general practice; coordinators should audit their use. Practice staff need to discuss, with their screening co-ordinator, how different practice staff can promote chlamydia screening most effectively using the NCSP promotional materials, and change them regularly so that they do not loose their impact. Education to change all practice staff's attitudes towards sexual health is needed to reduce their worries about displaying the chlamydia materials, and how they may follow up the advertising up with a verbal offer of screening opportunistically to 15-24 year olds whenever they visit the practice.
Promoting chlamydia screening with posters and leaflets in general practice - a qualitative study
Freeman, Elaine; Howell-Jones, Rebecca; Oliver, Isabel; Randall, Sarah; Ford-Young, William; Beckwith, Philippa; McNulty, Cliodna
2009-01-01
Background General practice staff are reluctant to discuss sexual health opportunistically in all consultations. Health promotion materials may help alleviate this barrier. Chlamydia screening promotion posters and leaflets, produced by the English National Chlamydia Screening Programme (NCSP), have been available to general practices, through local chlamydia screening offices, since its launch. In this study we explored the attitudes of general practice staff to these screening promotional materials, how they used them, and explored other promotional strategies to encourage chlamydia screening. Methods Twenty-five general practices with a range of screening rates, were purposively selected from six NCSP areas in England. In focus groups doctors, nurses, administrative staff and receptionists were encouraged to discuss candidly their experiences about their use and opinions of posters, leaflets and advertising to promote chlamydia screening. Researchers observed whether posters and leaflets were on display in reception and/or waiting areas. Data were collected and analysed concurrently using a stepwise framework analytical approach. Results Although two-thirds of screening practices reported that they displayed posters and leaflets, they were not prominently displayed in most practices. Only a minority of practices reported actively using screening promotional materials on an ongoing basis. Most staff in all practices were not following up the advertising in posters and leaflets by routinely offering opportunistic screening to their target population. Some staff in many practices thought posters and leaflets would cause offence or embarrassment to their patients. Distribution of chlamydia leaflets by receptionists was thought to be inappropriate by some practices, as they thought patients would be offended when being offered a leaflet in a public area. Practice staff suggested the development of pocket-sized leaflets. Conclusion The NCSP should consider developing a range of more discrete but eye catching posters and small leaflets specifically to promote chlamydia screening in different scenarios within general practice; coordinators should audit their use. Practice staff need to discuss, with their screening co-ordinator, how different practice staff can promote chlamydia screening most effectively using the NCSP promotional materials, and change them regularly so that they do not loose their impact. Education to change all practice staff's attitudes towards sexual health is needed to reduce their worries about displaying the chlamydia materials, and how they may follow up the advertising up with a verbal offer of screening opportunistically to 15-24 year olds whenever they visit the practice. PMID:19821964
BSM Delta Qualification 2, volume 2
NASA Technical Reports Server (NTRS)
1994-01-01
This report, presented in three volumes, provides the results of a two-motor Delta Qualification 2 program conducted in 1993 to certify the following enhancements for incorporation into booster separation motor (BSM) flight hardware: vulcanized-in-place nozzle aft closure insulation; new iso-static ATJ bulk graphite throat insert material; adhesive EA 9394 for bonding the nozzle throat, igniter grain rod/centering insert/igniter case; deletion of the igniter adapter insulator ring; deletion of the igniter adapter/igniter case interface RTV; and deletion of loctite from igniter retainer plate threads. The enhancements above directly resulted from (1) the BSM total quality management (TQM) team initiatives to enhance the BSM producibility, and (2) the necessity to qualify new throat insert and adhesive systems to replace existing materials that will not be available. Testing was completed at both the component and motor levels. Component testing was accomplished to screen candidate materials (e.g., throat materials, adhesive systems) and to optimize processes (e.g., aft closure insulator vulcanization approach) prior to their incorporation into the test motors. Motor tests -- consisting of two motors, randomly selected by USBI's on-site quality personnel from production lot AAY, which were modified to accept the enhancements -- were completed to provide the final qualification of the enhancements for incorporation into flight hardware. Volume 2 details the environmental testing (vibration and shock) conducted at Marshall Space Flight Center (MSFC) to which the motors were subjected prior to static tests.
Role of optometry school in single day large scale school vision testing
Anuradha, N; Ramani, Krishnakumar
2015-01-01
Background: School vision testing aims at identification and management of refractive errors. Large-scale school vision testing using conventional methods is time-consuming and demands a lot of chair time from the eye care professionals. A new strategy involving a school of optometry in single day large scale school vision testing is discussed. Aim: The aim was to describe a new approach of performing vision testing of school children on a large scale in a single day. Materials and Methods: A single day vision testing strategy was implemented wherein 123 members (20 teams comprising optometry students and headed by optometrists) conducted vision testing for children in 51 schools. School vision testing included basic vision screening, refraction, frame measurements, frame choice and referrals for other ocular problems. Results: A total of 12448 children were screened, among whom 420 (3.37%) were identified to have refractive errors. 28 (1.26%) children belonged to the primary, 163 to middle (9.80%), 129 (4.67%) to secondary and 100 (1.73%) to the higher secondary levels of education respectively. 265 (2.12%) children were referred for further evaluation. Conclusion: Single day large scale school vision testing can be adopted by schools of optometry to reach a higher number of children within a short span. PMID:25709271
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blau, P.; Qu, J.; Higdon, C. III
This industry-driven project was the result of a successful response by Eaton Corporation to a DOE/ITP Program, Grand Challenge, industry call. It consisted of a one-year effort in which ORNL participated in the area of friction and wear testing. In addition to Eaton Corporation and ORNL (CRADA), the project team included: Ames Laboratory, who developed the underlying concept for titanium- zirconium-boron (TZB) based nanocomposite coatings; Borg-Warner Morse TEC, an automotive engine timing chain manufacturer in Ithaca, New York, with its own proprietary hard coating; and Pratt & Whitney Rocketdyne, Inc., a dry-solids pump manufacturer in San Fernando Valley, California. Thismore » report focuses only on the portion of work that was conducted by ORNL, in a CRADA with Eaton Corporation. A comprehensive final report for the entire effort, which ended in September 2010, has been prepared for DOE by the team. The term 'ultracoatings' derives from the ambitious technical target for the new generation of nanocoatings. As applications, Eaton was specifically considering a fuel pump and a gear application in which the product of the contact pressure and slip velocity during operation of mating surfaces, commonly called the 'PV value', was equal to or greater than 70,000 MPa-m/s. This ambitious target challenges the developers of coatings to produce material capable of strong bonding to the substrate, as well as high wear resistance and the ability to maintain sliding friction at low, energy-saving levels. The partners in this effort were responsible for the selection and preparation of such candidate ultracoatings, and ORNL used established tribology testing capabilities to help screen these candidates for performance. This final report summarizes ORNL's portion of the nanocomposite coatings development effort and presents both generated data and the analyses that were used in the course of this effort. Initial contact stress and speed calculations showed that laboratory tests with available geometries, applied forces, and speeds at ORNL could not reach 70,000 MPa-m/s for the project target, so test conditions were modified to enable screening of the new coating compositions under conditions used in a prior nano-coatings development project with Eaton Corporation and Ames Laboratory. Eaton Innovation Center was able to conduct screening tests at higher loads and speeds, thus providing complementary information on coating durability and friction reduction. Those results are presented in the full team's final report which is in preparation at this writing. Tests of two types were performed at ORNL during the course of this work: (1) simulations of timing chain wear and friction under reciprocating conditions, and (2) pin-on-disk screening tests for bearings undergoing unidirectional sliding. The four materials supplied for evaluation in a timing chain link simulation were hardened type 440B stainless steel, nitrided type 440B stainless steel, vanadium carbide (VC)-coated type 52100 bearing steel, and (ZrTi)B-coated type 52100 bearing steel. Reciprocating wear tests revealed that the VC coating was by far the most wear resistant. In friction, the nitrided stainless steel did slightly better than the other materials.« less
To Screen or Not to Screen? The Benefits and Harms of Screening Tests
... issue To Screen or Not to Screen? The Benefits and Harms of Screening Tests En español Send ... test, talk with your doctor about the possible benefits and harms to help you decide what’s best ...
Smart material screening machines using smart materials and controls
NASA Astrophysics Data System (ADS)
Allaei, Daryoush; Corradi, Gary; Waigand, Al
2002-07-01
The objective of this product is to address the specific need for improvements in the efficiency and effectiveness in physical separation technologies in the screening areas. Currently, the mining industry uses approximately 33 billion kW-hr per year, costing 1.65 billion dollars at 0.05 cents per kW-hr, of electrical energy for physical separations. Even though screening and size separations are not the single most energy intensive process in the mining industry, they are often the major bottleneck in the whole process. Improvements to this area offer tremendous potential in both energy savings and production improvements. Additionally, the vibrating screens used in the mining processing plants are the most costly areas from maintenance and worker health and safety point of views. The goal of this product is to reduce energy use in the screening and total processing areas. This goal is accomplished by developing an innovative screening machine based on smart materials and smart actuators, namely smart screen that uses advanced sensory system to continuously monitor the screening process and make appropriate adjustments to improve production. The theory behind the development of Smart Screen technology is based on two key technologies, namely smart actuators and smart Energy Flow ControlT (EFCT) strategies, developed initially for military applications. Smart Screen technology controls the flow of vibration energy and confines it to the screen rather than shaking much of the mass that makes up the conventional vibratory screening machine. Consequently, Smart Screens eliminates and downsizes many of the structural components associated with conventional vibratory screening machines. As a result, the surface area of the screen increases for a given envelope. This increase in usable screening surface area extends the life of the screens, reduces required maintenance by reducing the frequency of screen change-outs and improves throughput or productivity.
Hydraulic tests with direct-push equipment
Butler, J.J.; Healey, J.M.; McCall, G.W.; Garnett, E.J.; Loheide, Steven P.
2002-01-01
The potential of direct-push technology for hydraulic characterization of saturated flow systems was investigated at a field site with a considerable degree of subsurface control. Direct-push installations were emplaced by attaching short lengths of screen (shielded and unshielded) to the bottom end of a tool string that was then advanced into the unconsolidated sediments. A series of constant-rate pumping tests were performed in a coarse sand and gravel aquifer using direct-push tool strings as observation wells. Very good agreement (within 4%) was found between hydraulic conductivity (K) estimates from direct-push installations and those from conventional wells. A program of slug tests was performed in direct-push installations using small-diameter adaptations of solid-slug and pneumatic methods. In a sandy silt interval of moderate hydraulic conductivity, K values from tests in a shielded screen tool were in excellent agreement (within 2%) with those from tests in a nearby well. In the coarse sand and gravel aquifer, K values were within 12% of those from multilevel slug tests at a nearby well. However, in the more permeable portions of the aquifer (K > 70 m/day), the smaller-diameter direct-push rods (0.016 m inner diameter [I.D.]) attenuated test responses, leading to an underprediction of K. In those conditions, use of larger-diameter rods (e.g., 0.038 m I.D.) is necessary to obtain K values representative of the formation. This investigation demonstrates that much valuable information can be obtained from hydraulic tests in direct-push installations. As with any type of hydraulic test, K estimates are critically dependent on use of appropriate emplacement and development procedures. In particular, driving an unshielded screen through a heterogeneous sequence will often lead to a buildup of low-K material that can be difficult to remove with standard development procedures.
Hot piston ring/cylinder liner materials: Selection and evaluation
NASA Technical Reports Server (NTRS)
Sliney, Harold E.
1988-01-01
In current designs of the automotive (kinematic) Stirling engine, the piston rings are made of a reinforced polymer and are located below the pistons because they cannot withstand the high temperatures in the upper cylinder area. Theoretically, efficiency could be improved if hot piston rings were located near the top of the pistons. Described is a program to select piston ring and cylinder coating materials to test this theory. Candidate materials were screened, then subjected to a pin or disk friction and wear test machine. Tests were performed in hydrogen at specimen temperatures up to 760 C to simulate environmental conditions in the region of the hot piston ring reversal. Based on the results of these tests, a cobalt based alloy, Stellite 6B, was chosen for the piston rings and PS200, which consists of a metal-bonded chromium carbide matrix with dispersed solid lubricants, was chosen as the cylinder coating. Tests of a modified engine and a baseline engine showed that the hot ring reduced specific fuel consumption by up to 7 percent for some operating conditions and averaged about 3 percent for all conditions evaluated. Related applications of high-temperature coatings for shaft seals and as back-up lubricants are also described.
Strategies to Improve Repeat Fecal Occult Blood Testing Cancer Screening
Davis, Terry C.; Arnold, Connie L.; Bennett, Charles L.; Wolf, Michael S.; Reynolds, Cristalyn; Liu, Dachao; Rademaker, Alfred
2013-01-01
Background A comparative effectiveness intervention by this team improved initial fecal occult blood testing (FOBT) rates from 3% to 53% among community clinic patients. The purpose of this study was to evaluate the effectiveness and costs associated with a literacy-informed intervention on repeat FOBT testing. Methods Between 2008 and 2011, a three-arm quasi-experiential comparative effectiveness evaluation was conducted in 8 community clinics in Louisiana. Clinics were randomly assigned to receive: enhanced care, a screening recommendation and FOBT kit annually; a brief educational intervention where patients additionally received a literacy appropriate pamphlet and simplified FOBT instructions; or nurse support where a nurse manager provided the education and followed up with phone support. In year 2 all materials were mailed. The study consisted of 461 patients, ages 50–85, with a negative initial FOBT. Results Repeat FOBT rates were 38% enhanced care, 33% education, and 59% with nurse support (p=0.017). After adjusting for age, race, gender, and literacy, patients receiving nurse support were 1.46 times more likely to complete repeat FOBT screening than those receiving education (95% CI 1.14–1.06, p=0.002) and 1.45 times more likely than those in enhanced care but this was not significant (95% CI 0.93–2.26 p=0.10). The incremental cost per additional person screened was $2,450 for nurse over enhanced care. Conclusion A mailed pamphlet and FOBT with simplified instructions did not improve annual screening. Impact Telephone outreach by a nurse manager was effective in improving rates of repeat FOBT yet this may be too costly for community clinics. PMID:24192009
Evaluation of high temperature structural adhesives for extended service
NASA Technical Reports Server (NTRS)
Hill, S. G.; Peters, P. D.; Hendricks, C. L.
1982-01-01
The evaluation, selection, and demonstration of structural adhesive systems for supersonic cruise research applications, and establishment of environmental durability of selected systems for up to 20,000 hours is described. Ten candidate adhesives were initially evaluated. During screening and evaluation, these candidates were narrowed to three of the most promising for environmental durability testing. The three adhesives were LARC-13, PPQ, and NR056X. The LARC-13 was eliminated because of a lack of stability at 505 K. The NRO56X was removed from the market. The LARC-TPI was added after preliminary evaluation and an abbreviated screening test. Only PPQ and LARC-TPI remained as the reasonable candidates late into the durability testing. Large area bond panels were fabricated to demonstrate the processibility of the selected systems. Specifications were prepared to assure control over critical material and process parameters. Surface characterization concentrated primarily upon titanium surface treatments of 10 volt chronic acid anodize, 5 volt chromic acid anodize and PASA-JELL. Failure analysis was conducted on lap shear adhesive bond failures which occurred in PPQ and LARC-13 test specimens after 10,000 hours at 505 K.
Rapid screening test for porphyria diagnosis using fluorescence spectroscopy
NASA Astrophysics Data System (ADS)
Lang, A.; Stepp, H.; Homann, C.; Hennig, G.; Brittenham, G. M.; Vogeser, M.
2015-07-01
Porphyrias are rare genetic metabolic disorders, which result from deficiencies of enzymes in the heme biosynthesis pathway. Depending on the enzyme defect, different types of porphyrins and heme precursors accumulate for the different porphyria diseases in erythrocytes, liver, blood plasma, urine and stool. Patients with acute hepatic porphyrias can suffer from acute neuropathic attacks, which can lead to death when undiagnosed, but show only unspecific clinical symptoms such as abdominal pain. Therefore, in addition to chromatographic methods, a rapid screening test is required to allow for immediate identification and treatment of these patients. In this study, fluorescence spectroscopic measurements were conducted on blood plasma and phantom material, mimicking the composition of blood plasma of porphyria patients. Hydrochloric acid was used to differentiate the occurring porphyrins (uroporphyrin-III and coproporphyrin-III) spectroscopically despite their initially overlapping excitation spectra. Plasma phantom mixtures were measured using dual wavelength excitation and the corresponding concentrations of uroporphyrin-III and coproporphyrin-III were determined. Additionally, three plasma samples of porphyria patients were examined and traces of coproporphyrin-III and uroporphyrin-III were identified. This study may therefore help to establish a rapid screening test method with spectroscopic differentiation of the occurring porphyrins, which consequently allows for the distinction of different porphyrias. This may be a valuable tool for clinical porphyria diagnosis and rapid or immediate treatment.
Hudson, Janella N; Quinn, Gwendolyn P; Wilson, Lauren E; Simmons, Vani N
2017-03-11
Low-dose computed tomography (LDCT) screening is a promising screening modality for increasing the detection rate of early stage lung cancers among high-risk individuals. Despite being recommended by the US Preventative Services Task Force, uptake of LDCT remains low. The objective of the current study was to gather feedback from high-risk consumers and health care providers on LDCT promotional materials. Focus group discussions were conducted with high-risk individuals (8 focus groups; N = 38) and primary care providers (9 focus groups; N = 23). Participants reviewed existing LDCT promotional materials to assess their perceptions of media materials created to publicize LDCT. Data were analyzed using the constant comparative method. Several key themes emerged from focus groups that can be used to inform development of future LDCT promotional materials. High-risk (HR) participants expressed greater receptivity for promotional materials that did not further stigmatize lung cancer and/or smoking and expressed preferences for materials that clearly outlined the risks/benefits of screening. Primary care providers (PCPs) offered suggestions to facilitate the referral process such as diagnostic codes and requested a design that clearly outlined eligibility criteria. A clear and thorough explanation of LDCT eligibility, cost, harms, and benefits was of chief importance for both PCP and HR audiences. Given that PCPs and HR audiences are not well informed on the specifics of LDCT screening eligibility and insurance coverage, creating provider and patient education opportunities will aid in shared decision-making opportunities. Promotional materials that meet the needs of the target audience are needed to facilitate discussions of risks/benefits of screening with HR individuals.
Affordable Development and Optimization of CERMET Fuels for NTP Ground Testing
NASA Technical Reports Server (NTRS)
Hickman, Robert R.; Broadway, Jeramie W.; Mireles, Omar R.
2014-01-01
CERMET fuel materials for Nuclear Thermal Propulsion (NTP) are currently being developed at NASA's Marshall Space Flight Center. The work is part of NASA's Advanced Space Exploration Systems Nuclear Cryogenic Propulsion Stage (NCPS) Project. The goal of the FY12-14 project is to address critical NTP technology challenges and programmatic issues to establish confidence in the affordability and viability of an NTP system. A key enabling technology for an NCPS system is the fabrication of a stable high temperature nuclear fuel form. Although much of the technology was demonstrated during previous programs, there are currently no qualified fuel materials or processes. The work at MSFC is focused on developing critical materials and process technologies for manufacturing robust, full-scale CERMET fuels. Prototypical samples are being fabricated and tested in flowing hot hydrogen to understand processing and performance relationships. As part of this initial demonstration task, a final full scale element test will be performed to validate robust designs. The next phase of the project will focus on continued development and optimization of the fuel materials to enable future ground testing. The purpose of this paper is to provide a detailed overview of the CERMET fuel materials development plan. The overall CERMET fuel development path is shown in Figure 2. The activities begin prior to ATP for a ground reactor or engine system test and include materials and process optimization, hot hydrogen screening, material property testing, and irradiation testing. The goal of the development is to increase the maturity of the fuel form and reduce risk. One of the main accomplishmens of the current AES FY12-14 project was to develop dedicated laboratories at MSFC for the fabrication and testing of full length fuel elements. This capability will enable affordable, near term development and optimization of the CERMET fuels for future ground testing. Figure 2 provides a timeline of the development and optimization tasks for the AES FY15-17 follow on program.
Cervical cancer screening: A never-ending developing program
Comparetto, Ciro; Borruto, Franco
2015-01-01
With the term “oncological screening”, we define the overall performances made to detect early onset of tumors. These tests are conducted on a population that does not have any signs or symptoms related to a neoplasm. The whole population above a certain age, only one sex, only subjects with a high risk of developing cancer due to genetic, professional, discretionary reasons may be involved. Screening campaigns should be associated, when risk factors that can be avoided are known, with campaigns for the prevention of cancer by means of suitable behavior. The goal of cancer screening cannot however be limited to the diagnosis of a greater number of neoplasms. Screening will be useful only if it leads to a reduction in overall mortality or at least in mortality related to the tumor. Screening should then allow the diagnosis of the disease at a stage when there is a possibility of healing, possibility that is instead difficult when the disease is diagnosed at the appearance of signs or symptoms. This is the reason why not all campaigns of cancer screening have the same effectiveness. In Italy, every year there are about 150000 deaths due to cancer. Some of these tumors can be cured with a very high percentage of success if diagnosed in time. Cervical cancer can be diagnosed with non-invasive tests. The screening test used all over the world is Papanicolaou (Pap) test. This test may be carried out over the entire healthy population potentially exposed to the risk of contracting cancer. Public health has begun the screening campaigns in the hope of saving many of the approximately 270000 new cases of cancer reported each year. Screening is done following protocols that guarantee quality at the national level: these protocols are subject to change over time to reflect new realities or to correct any errors in the system. A simplified sketch of a possible route of cancer screening is as follows: (1) after selecting the target population, for example all women between 25 and 64 years (in the case of monitoring of cervical cancer), an invitation letter with the date and time of the appointment, planned according to the acceptance capacity of the hospital, is sent to all individuals; (2) an examination, which depending on the individual and the type of cancer to be monitored, for example, can be a Pap smear, is performed and the patient can go home; (3) once available the results of examinations, if negative, they shall be communicated to the person concerned that will be notified by mail and will be recalled for a second test at a few years of distance, in the case of non-negativity, instead, the patient is contacted by telephone and informed of the need to carry out further examinations: it is said that the patient is in the “phase two” of the screening pathway; (4) in phase two, reached by only a small portion of the interested parties (usually less than 3%-5%), more in-depth tests are carried out, which, depending on the individual and the type of cancer, can be: cytological and colposcopic examinations, the removal of a fragment of tissue (biopsy) and subsequent histological examination, additional tests such as ultrasound, radiography, or others such as computerized tomography, magnetic resonance imaging, positron emission tomography, etc., in case of negativity, the concerned person will be called for new control tests at a a few years of distance, in case of non-negativity, it will be proposed instead an oncologic therapeutic plan and/or surgery to treat the diagnosed tumor; and (5) once the treatment plan is completed, the individual enters the follow-up protocol, which is monitored over time to see if the tumor has been completely removed or if instead it is still developing. Cervical cancer is undoubtedly the most successful example of a cancer screening campaign. Paradoxically, its effectiveness is one of the strongest reasons to criticize the usefulness of vaccination against human papillomavirus (HPV) in countries where the screening service with Pap test is organized in an efficient manner. Cervical cancer screening protocols are directed to sexually active women aged 25-64 years: they provide the Pap test performed by examining under a microscope or by staining with a specific “thin prep” the material taken from the cervix with a small spatula and a brush. It is recommended to repeat the test every two or three years. It is important to emphasize that women vaccinated against HPV must continue the screening with Pap test. Although some screening programs (e.g., Pap smears) have had remarkable success in reducing mortality from a specific cancer, any kind of screening is free from inherent limitations. The screening methods are in fact applied to large parts of the apparently healthy population. In particular, the limits for certain cancers may be as obvious as to prohibit the introduction of an organized screening program. Potential limitations of organized screenings are basically of two types: organizational and medical. The limits of organizational type relate to the ability of a program to recruit the whole target population. Although well organized, a screening program will hardly be able to exceed a coverage of 70%-80% of the target population, and in fact the results of the current programs are often much smaller. The limits of medical type are represented by the possibility of reducing the overall mortality, or specific mortality, using a specific screening campaign. PMID:26244153
A Smartphone App to Screen for HIV-Related Neurocognitive Impairment
Robbins, Reuben N.; Brown, Henry; Ehlers, Andries; Joska, John A.; Thomas, Kevin G.F.; Burgess, Rhonda; Byrd, Desiree; Morgello, Susan
2014-01-01
Background Neurocognitive Impairment (NCI) is one of the most common complications of HIV-infection, and has serious medical and functional consequences. However, screening for it is not routine and NCI often goes undiagnosed. Screening for NCI in HIV disease faces numerous challenges, such as limited screening tests, the need for specialized equipment and apparatuses, and highly trained personnel to administer, score and interpret screening tests. To address these challenges, we developed a novel smartphone-based screening tool, NeuroScreen, to detect HIV-related NCI that includes an easy-to-use graphical user interface with ten highly automated neuropsychological tests. Aims To examine NeuroScreen’s: 1) acceptability among patients and different potential users; 2) test construct and criterion validity; and 3) sensitivity and specificity to detect NCI. Methods Fifty HIV+ individuals were administered a gold-standard neuropsychological test battery, designed to detect HIV-related NCI, and NeuroScreen. HIV+ test participants and eight potential provider-users of NeuroScreen were asked about its acceptability. Results There was a high level of acceptability of NeuroScreen by patients and potential provider-users. Moderate to high correlations between individual NeuroScreen tests and paper-and-pencil tests assessing the same cognitive domains were observed. NeuroScreen also demonstrated high sensitivity to detect NCI. Conclusion NeuroScreen, a highly automated, easy-to-use smartphone-based screening test to detect NCI among HIV patients and usable by a range of healthcare personnel could help make routine screening for HIV-related NCI feasible. While NeuroScreen demonstrated robust psychometric properties and acceptability, further testing with larger and less neurocognitively impaired samples is warranted. PMID:24860624
NASA Astrophysics Data System (ADS)
Stefan-van Staden, Raluca-Ioana; Comnea-Stancu, Ionela Raluca; Surdu-Bob, Carmen Cristina; Badulescu, Marius
2015-09-01
New nanostructured materials based on thin films of Cu and Ni deposited on textile material (veil), as well as gold nanostructured microspheres were used for the design of new stochastic sensors. The stochastic sensors were able to detect simultaneously a panel of biomarkers comprising epidermal growth factor receptor, neuron specific enolase, and carcinoembryonic antigen from whole blood samples with high reliabilities - recovery tests higher than 97.00%, with a RSD (%) lower than 0.1%. The stochastic sensors had shown high sensitivities and low determination levels for the detection of the proposed panel of biomarkers making early detection of lung cancer possible by fast screening of whole blood.
Method to predict relative hydriding within a group of zirconium alloys under nuclear irradiation
Johnson, A.B. Jr.; Levy, I.S.; Trimble, D.J.; Lanning, D.D.; Gerber, F.S.
1990-04-10
An out-of-reactor method for screening to predict relative in-reactor hydriding behavior of zirconium-based materials is disclosed. Samples of zirconium-based materials having different compositions and/or fabrication methods are autoclaved in a relatively concentrated (0.3 to 1.0M) aqueous lithium hydroxide solution at constant temperatures within the water reactor coolant temperature range (280 to 316 C). Samples tested by this out-of-reactor procedure, when compared on the basis of the ratio of hydrogen weight gain to oxide weight gain, accurately predict the relative rate of hydriding for the same materials when subject to in-reactor (irradiated) corrosion. 1 figure.
Ma, Changxi; Hao, Wei; Pan, Fuquan; Xiang, Wang
2018-01-01
Route optimization of hazardous materials transportation is one of the basic steps in ensuring the safety of hazardous materials transportation. The optimization scheme may be a security risk if road screening is not completed before the distribution route is optimized. For road screening issues of hazardous materials transportation, a road screening algorithm of hazardous materials transportation is built based on genetic algorithm and Levenberg-Marquardt neural network (GA-LM-NN) by analyzing 15 attributes data of each road network section. A multi-objective robust optimization model with adjustable robustness is constructed for the hazardous materials transportation problem of single distribution center to minimize transportation risk and time. A multi-objective genetic algorithm is designed to solve the problem according to the characteristics of the model. The algorithm uses an improved strategy to complete the selection operation, applies partial matching cross shift and single ortho swap methods to complete the crossover and mutation operation, and employs an exclusive method to construct Pareto optimal solutions. Studies show that the sets of hazardous materials transportation road can be found quickly through the proposed road screening algorithm based on GA-LM-NN, whereas the distribution route Pareto solutions with different levels of robustness can be found rapidly through the proposed multi-objective robust optimization model and algorithm.
... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... or routine screening test for prostate cancer. Screening tests for prostate cancer are under study, and there are screening clinical trials taking place ...
1986-06-01
of the metabolic effects of exposure to the suspended solid phase during the screening experiments with only modest additional costs. Like- .. wise...assays MUST continue for 10 days, durinq which time daily records must be kept of salinity , temperature, DO, obvious mortalities and any sublethal effects ...25 Adenylate Energy Charge. ................. 26 . Oxygen Consumption and Osmoregulation . .......... 26 Miscellaneous. ..................... 26
An effective method to screen sodium-based layered materials for sodium ion batteries
NASA Astrophysics Data System (ADS)
Zhang, Xu; Zhang, Zihe; Yao, Sai; Chen, An; Zhao, Xudong; Zhou, Zhen
2018-03-01
Due to the high cost and insufficient resource of lithium, sodium-ion batteries are widely investigated for large-scale applications. Typically, insertion-type materials possess better cyclic stability than alloy-type and conversion-type ones. Therefore, in this work, we proposed a facile and effective method to screen sodium-based layered materials based on Materials Project database as potential candidate insertion-type materials for sodium ion batteries. The obtained Na-based layered materials contains 38 kinds of space group, which reveals that the credibility of our screening approach would not be affected by the space group. Then, some important indexes of the representative materials, including the average voltage, volume change and sodium ion mobility, were further studied by means of density functional theory computations. Some materials with extremely low volume changes and Na diffusion barriers are promising candidates for sodium ion batteries. We believe that our classification algorithm could also be used to search for other alkali and multivalent ion-based layered materials, to accelerate the development of battery materials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwartz, Grace E.; Hower, James C.; Phillips, Allison L.
The chemical composition of coal ash is highly heterogeneous and dependent on the origin of the source coal, combustion parameters, and type and configuration of air pollution control devices. This heterogeneity results in uncertainty in the evaluation of leaching potential of contaminants from coal ash. The goal of this work was to identify whether a single leaching protocol could roughly group high-leaching potential coal ash from low-leaching potential coal ash, with respect to arsenic (As) and selenium (Se). We used four different leaching tests, including the Toxicity Characteristic Leaching Protocol (TCLP), natural pH, aerobic sediment microcosms, and anaerobic sediment microcosmsmore » on 10 different coal ash materials, including fly ash, lime-treated ash, and flue gas desulfurization materials. Leaching tests showed promise in categorizing high and low-leaching potential ash materials, indicating that a single point test could act as a first screening measure to identify high-risk ash materials. However, the amount of contaminant leached varied widely across tests, reflecting the importance of ambient conditions (pH, redox state) on leaching. These results demonstrate that on-site geochemical conditions play a critical role in As and Se mobilization from coal ash, underscoring the need to develop a situation-based risk assessment framework for contamination by coal ash pollutants.« less
Schwartz, Grace E.; Hower, James C.; Phillips, Allison L.; ...
2018-01-23
The chemical composition of coal ash is highly heterogeneous and dependent on the origin of the source coal, combustion parameters, and type and configuration of air pollution control devices. This heterogeneity results in uncertainty in the evaluation of leaching potential of contaminants from coal ash. The goal of this work was to identify whether a single leaching protocol could roughly group high-leaching potential coal ash from low-leaching potential coal ash, with respect to arsenic (As) and selenium (Se). We used four different leaching tests, including the Toxicity Characteristic Leaching Protocol (TCLP), natural pH, aerobic sediment microcosms, and anaerobic sediment microcosmsmore » on 10 different coal ash materials, including fly ash, lime-treated ash, and flue gas desulfurization materials. Leaching tests showed promise in categorizing high and low-leaching potential ash materials, indicating that a single point test could act as a first screening measure to identify high-risk ash materials. However, the amount of contaminant leached varied widely across tests, reflecting the importance of ambient conditions (pH, redox state) on leaching. These results demonstrate that on-site geochemical conditions play a critical role in As and Se mobilization from coal ash, underscoring the need to develop a situation-based risk assessment framework for contamination by coal ash pollutants.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duan, Yuhua
2012-11-02
Since current technologies for capturing CO{sub 2} to fight global climate change are still too energy intensive, there is a critical need for development of new materials that can capture CO{sub 2} reversibly with acceptable energy costs. Accordingly, solid sorbents have been proposed to be used for CO{sub 2} capture applications through a reversible chemical transformation. By combining thermodynamic database mining with first principles density functional theory and phonon lattice dynamics calculations, a theoretical screening methodology to identify the most promising CO{sub 2} sorbent candidates from the vast array of possible solid materials has been proposed and validated. The calculatedmore » thermodynamic properties of different classes of solid materials versus temperature and pressure changes were further used to evaluate the equilibrium properties for the CO{sub 2} adsorption/desorption cycles. According to the requirements imposed by the pre- and post- combustion technologies and based on our calculated thermodynamic properties for the CO{sub 2} capture reactions by the solids of interest, we were able to screen only those solid materials for which lower capture energy costs are expected at the desired pressure and temperature conditions. Only those selected CO{sub 2} sorbent candidates were further considered for experimental validations. The ab initio thermodynamic technique has the advantage of identifying thermodynamic properties of CO{sub 2} capture reactions without any experimental input beyond crystallographic structural information of the solid phases involved. Such methodology not only can be used to search for good candidates from existing database of solid materials, but also can provide some guidelines for synthesis new materials. In this presentation, we first introduce our screening methodology and the results on a testing set of solids with known thermodynamic properties to validate our methodology. Then, by applying our computational method to several different kinds of solid systems, we demonstrate that our methodology can predict the useful information to help developing CO{sub 2} capture Technologies.« less
Can tailored interventions increase mammography use among HMO women?
Lipkus, I M; Rimer, B K; Halabi, S; Strigo, T S
2000-01-01
Telephone counseling and tailored print communications have emerged as promising methods for promoting mammography screening. However, there has been little research testing, within the same randomized field trial, of the efficacy of these two methods compared to a high-quality usual care system for enhancing screening. This study addressed the question: Compared to usual care, is tailored telephone counseling more effective than tailored print materials for promoting mammography screening? Three-year randomized field trial. One thousand ninety-nine women aged 50 and older recruited from a health maintenance organization in North Carolina. Women were randomized to 1 of 3 groups: (1) usual care, (2) tailored print communications, and (3) tailored telephone counseling. Adherence to mammography screening based on self-reports obtained during 1995, 1996, and 1997. Compared to usual care alone, telephone counseling promoted a significantly higher proportion of women having mammograms on schedule (71% vs 61%) than did tailored print (67% vs 61%) but only after the first year of intervention (during 1996). Furthermore, compared to usual care, telephone counseling was more effective than tailored print materials at promoting being on schedule with screening during 1996 and 1997 among women who were off-schedule during the previous year. The effects of the intervention were most pronounced after the first intervention. Compared to usual care, telephone counseling seemed particularly effective at promoting change among nonadherent women, the group for whom the intervention was developed. These results suggest that telephone counseling, rather than tailored print, might be the preferred first-line intervention for getting nonadherent women on schedule for mammography screening. Many questions would have to be answered about why the tailored print intervention was not more powerful. Nevertheless, it is clear that additional interventions will be needed to maintain women's adherence to mammography. Medical Subject Headings (MeSH): mammography screening, telephone counseling, tailored print communications, barriers.
Hankin, Abigail; Freiman, Heather; Copeland, Brittney; Travis, Natasha; Shah, Bijal
2016-01-01
This study compared two approaches for implementation of non-targeted HIV screening in the emergency department (ED): (1) designated HIV counselors screening in parallel with ED care and (2) nurse-based screening integrated into patient triage. A retrospective analysis was performed to compare parallel and integrated screening models using data from the first 12 months of each program. Data for the parallel screening model were extracted from information collected by HIV test counselors and the electronic medical record (EMR). Integrated screening model data were extracted from the EMR and supplemented by data collected by HIV social workers during patient interaction. For both programs, data included demographics, HIV test offer, test acceptance or declination, and test result. A Z-test between two proportions was performed to compare screening frequencies and results. During the first 12 months of parallel screening, approximately 120,000 visits were made to the ED, with 3,816 (3%) HIV tests administered and 65 (2%) new diagnoses of HIV infection. During the first 12 months of integrated screening, 111,738 patients were triaged in the ED, with 16,329 (15%) patients tested and 190 (1%) new diagnoses. Integrated screening resulted in an increased frequency of HIV screening compared with parallel screening (0.15 tests per ED patient visit vs. 0.03 tests per ED patient visit, p<0.001) and an increase in the absolute number of new diagnoses (190 vs. 65), representing a slight decrease in the proportion of new diagnoses (1% vs. 2%, p=0.007). Non-targeted, integrated HIV screening, with test offer and order by ED nurses during patient triage, is feasible and resulted in an increased frequency of HIV screening and a threefold increase in the absolute number of newly identified HIV-positive patients.
Padela, Aasim I.; Peek, Monica; Johnson-Agbakwu, Crista E.; Hosseinian, Zahra; Curlin, Farr
2015-01-01
Objective This study aimed to assess rates of Papanicolaou (Pap) testing and associations between religion-related factors and these rates among a racially and ethnically diverse sample of American Muslim women. Materials and Methods A community-based participatory research design was used in partnering with the Council of Islamic Organizations of Greater Chicago to recruit Muslim women attending mosque and community events. These participants self-administered surveys incorporating measures of fatalism, religiosity, perceived discrimination, Islamic modesty, and a marker of Pap test use. Results A total of 254 survey respondents were collected with nearly equal numbers of Arabs, South Asians, and African American respondents. Of these respondents, 84% had obtained a Pap test in their lifetime, with individuals who interpret disease as a manifestation of God’s punishment having a lower odds of having had Pap testing after controlling for sociodemographic factors (odds ratio [OR] = 0.87, 95% CI = 0.77–1.0). In multivariate models, living in the United States for more than 20 years (OR = 4.7, 95% CI = 1.4–16) and having a primary care physician (OR = 7.7, 95% CI = 2.5–23.4) were positive predictors of having had a Pap test. Ethnicity, fatalistic beliefs, perceived discrimination, and modesty levels were not significantly associated with Pap testing rates. Conclusions To our knowledge, this is the first study to assess Pap testing behaviors among a diverse sample of American Muslim women and to observe that negative religious coping (e.g., viewing health problems as a punishment from God) is associated with a lower odds of obtaining a Pap test. The relationship between religious coping and cancer screening behaviors deserves further study so that religious values can be appropriately addressed through cancer screening programs. PMID:24914883
Risks of Prostate Cancer Screening
... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... or routine screening test for prostate cancer. Screening tests for prostate cancer are under study, and there are screening clinical trials taking place ...
Delayed-type hypersensitivity to fragrance materials in a select North American population.
Belsito, Donald V; Fowler, Joseph F; Sasseville, Denis; Marks, James G; De Leo, Vincent A; Storrs, Frances J
2006-03-01
In published reports from Europe, 3- and 4-(4-hydroxy-4-methylpentyl)cyclohexene-1-carboxaldehyde (HMPCC) (Lyral) has been described as a common cause of allergic contact dermatitis (ACD). In Europe, the rates of reaction to HMPCC among patients undergoing patch testing for suspected ACD have varied from 1.2 to 17.0%, depending on the country. Data on the incidence of sensitivity to HMPCC among North Americans with suspected ACD have not been reported. The goals of this study were (1) to assess the incidence of delayed-type hypersensitivity reactions to HMPCC among patients undergoing patch testing for evaluation of eczematous dermatitis at six centers throughout North America; (2) to determine the most appropriate concentration of HMPCC to use in performing patch tests; and (3) to compare and contrast the incidence rates for HMPCC hypersensitivity to those for other fragrance materials screened with the North American Contact Dermatitis Group (NACDG) screening tray, which includes fragrance mix, Myroxilon pereirae (balsam of Peru), cinnamic aldehyde, ylang ylang oil, jasmine absolute, and tea tree oil. This report represents the prospective multicenter data on patients tested with the fragrance-related allergens on the NACDG standard screening tray and with HMPCC at 5%, 1.5%, and 0.5% concentrations in petrolatum. Statistical analyses were performed with Student's t-test (two tailed) and the chi-square test. Data from 1,603 patients evaluated at five US sites and one Canadian site were analyzed. Most patients (87.8%) were Caucasian. The majority (67%) were women, and 26.2% had a history consistent with atopic dermatitis. The patients ranged in age from 1 to 88 years, and the mean +/- standard deviation was 46.3 +/- 16.5 years. Myroxilon pereirae (balsam of Peru) and fragrance mix were the most frequent patch-test-positive fragrance allergens (6.6% and 5.9%, respectively). Cinnamic aldehyde (1.7%), ylang ylang oil (0.6%), jasmine absolute (0.4%), HMPCC (0.4% for 5% HMPCC, 0.3% for 1.5% HMPCC, and 0.2% for 0.5% HMPCC), and tea tree oil (0.3%) less frequently yielded positive reactions. Men were more likely than women to be allergic to cinnamic aldehyde. Women were more likely than men to be allergic to jasmine absolute. Atopic patients were no more likely to react to fragrance materials than were nonatopic patients. Patients who reacted to jasmine absolute tended to be older than the general population whereas those who reacted to tea tree oil tended to be younger than the general population. There were no other demographic differences between patients who reacted to a given fragrance material and the entire population studied. Testing with fragrance mix and balsam of Peru failed to identify the majority of patients in this study who were found to be sensitized to jasmine absolute, HMPCC, or tea tree oil. HMPCC is an uncommon allergen in the North American population. We recommend testing with 5% HMPCC in petrolatum for those patients suspected of having a fragrance allergy.
Arnold, Larry R. Rick
2015-01-01
During May–June, 2013, the U.S. Geological Survey, in cooperation with Park County, Colorado, drilled and installed four groundwater monitoring wells in areas identified as needing new wells to provide adequate spatial coverage for monitoring water quality in the South Park basin. Lithologic logs and well-construction reports were prepared for each well, and wells were developed after drilling to remove mud and foreign material to provide for good hydraulic connection between the well and aquifer. Slug tests were performed to estimate hydraulic-conductivity values for aquifer materials in the screened interval of each well, and groundwater samples were collected from each well for analysis of major inorganic constituents, trace metals, nutrients, dissolved organic carbon, volatile organic compounds, ethane, methane, and radon. Documentation of lithologic logs, well construction, well development, slug testing, and groundwater sampling are presented in this report.
Superconductivity devices: Commercial use of space
NASA Technical Reports Server (NTRS)
Haertling, Gene; Furman, Eugene; Hsi, Chi-Shiung; Li, Guang
1993-01-01
The processing and screen printing of the superconducting BSCCO and 123 YBCO materials on substrates is described. The resulting superconducting properties and the use of these materials as possible electrode materials for ferroelectrics at 77 K are evaluated. Also, work performed in the development of solid-state electromechanical actuators is reported. Specific details include the fabrication and processing of high strain PBZT and PLZT electrostrictive materials, the development of PSZT and PMN-based ceramics, and the testing and evaluation of these electrostrictive materials. Finally, the results of studies on a new processing technology for preparing piezoelectric and electrostrictive ceramic materials are summarized. The process involves a high temperature chemical reduction which leads to an internal pre-stressing of the oxide wafer. These reduced and internally biased oxide wafers (RAINBOW) can produce bending-mode actuator devices which possess a factor of ten more displacement and load bearing capacity than present-day benders.
Sensitization of Laser-beam Welded Martensitic Stainless Steels
NASA Astrophysics Data System (ADS)
Dahmen, Martin; Rajendran, Kousika Dhasanur; Lindner, Stefan
Ferritic and martensitic stainless steels are an attractive alternative in vehicle production due to their inherent corrosion resistance. By the opportunity of press hardening, their strength can be increased to up to 2000 MPa, making them competitors for unalloyed ultra-high strength steels. Welding, nevertheless, requires special care, especially when it comes to joining of high strength heat treated materials. With an adopted in-line heat treatment of the welds in as-rolled as well as press hardened condition, materials with sufficient fatigue strength and acceptable structural behavior can be produced. Because of microstructural transformations in the base material such as grain coarsening and forced carbide precipitation, the corrosion resistance of the weld zone may be locally impaired. Typically the material in the heat-affected zone becomes sensitive to intergranular cracking in the form of knife-edge corrosion besides the fusion line. The current study comprises of two text scenarios. By an alternating climate test, general response in a corroding environment is screened. In order to understand the corrosion mechanisms and to localize the sensitive zones, sensitisation tests were undertaken. Furthermore, the applicability of a standard test according to ASTM 763-83 was examined. It was found that the alternative climate test does not reveal any corrosion effects. Testing by the oxalic acid test revealed clearly the effect of welding, weld heat treatment and state of thermal processing. Also application of the standard which originally suited for testing ferritic stainless steels could have been justified.
The effect of start and stop age at screening on the risk of being diagnosed with prostate cancer
Arnsrud Godtman, Rebecka; Carlsson, Sigrid; Holmberg, Erik; Stranne, Johan; Hugosson, Jonas
2016-01-01
Purpose The aim of this study was to investigate the effect of age and number of screens on the risk of prostate cancer (PCa) diagnosis. Materials and Methods The Göteborg randomized population-based PCa screening trial has, since 1995, invited men biennially for prostate-specific antigen (PSA)-testing, until the upper age limit 70 years. Men with a PSA-level above the threshold ≥2.5 ng/ml were recommended further work-up including 10-core biopsy (sextant before 2009). The present study comprises 9,065 men born 1930–43 (1944 excluded due to different screening algorithm). Complete attendees were defined as men who accepted all screening invitations (maximum 3–9 invitations). Cumulative incidence of PCa was calculated using standard methods. Results Of the 3,488 (38%) complete attendees, 667 were diagnosed with PCa (follow-up 1995–30 Jun 2014). At the age 70, there was no significant difference in PCa risk between those who started screening at the age of 52 (9 screens), 55 (7 screens) or 60 (5 screens) years. However, the cumulative risk of PCa diagnosis increased dramatically with age and was 7.9% at age 60, 15% at age 65 and 21% at age 70, for men who had been screened ≥4 times. Conclusion There was no clear association between risk of PCa and the number of screens. Starting screening at an early age appears to advance the time of PCa diagnosis but does not seem to increase the risk of being diagnosed with the disease. Age at termination of screening is strongly associated with the risk of being diagnosed with PCa. PMID:26678954
Smart Screening System (S3) In Taconite Processing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daryoush Allaei; Ryan Wartman; David Tarnowski
2006-03-01
The conventional screening machines used in processing plants have had undesirable high noise and vibration levels. They also have had unsatisfactorily low screening efficiency, high energy consumption, high maintenance cost, low productivity, and poor worker safety. These conventional vibrating machines have been used in almost every processing plant. Most of the current material separation technology uses heavy and inefficient electric motors with an unbalanced rotating mass to generate the shaking. In addition to being excessively noisy, inefficient, and high-maintenance, these vibrating machines are often the bottleneck in the entire process. Furthermore, these motors, along with the vibrating machines and supportingmore » structure, shake other machines and structures in the vicinity. The latter increases maintenance costs while reducing worker health and safety. The conventional vibrating fine screens at taconite processing plants have had the same problems as those listed above. This has resulted in lower screening efficiency, higher energy and maintenance cost, and lower productivity and workers safety concerns. The focus of this work is on the design of a high performance screening machine suitable for taconite processing plants. SmartScreens{trademark} technology uses miniaturized motors, based on smart materials, to generate the shaking. The underlying technologies are Energy Flow Control{trademark} and Vibration Control by Confinement{trademark}. These concepts are used to direct energy flow and confine energy efficiently and effectively to the screen function. The SmartScreens{trademark} technology addresses problems related to noise and vibration, screening efficiency, productivity, and maintenance cost and worker safety. Successful development of SmartScreens{trademark} technology will bring drastic changes to the screening and physical separation industry. The final designs for key components of the SmartScreens{trademark} have been developed. The key components include smart motor and associated electronics, resonators, and supporting structural elements. It is shown that the smart motors have an acceptable life and performance. Resonator (or motion amplifier) designs are selected based on the final system requirement and vibration characteristics. All the components for a fully functional prototype are fabricated. The development program is on schedule. The last semi-annual report described the completion of the design refinement phase. This phase resulted in a Smart Screen design that meets performance targets both in the dry condition and with taconite slurry flow using PZT motors. This system was successfully demonstrated for the DOE and partner companies at the Coleraine Mineral Research Laboratory in Coleraine, Minnesota. Since then, the fabrication of the dry application prototype (incorporating an electromagnetic drive mechanism and a new deblinding concept) has been completed and successfully tested at QRDC's lab.« less
NASA Astrophysics Data System (ADS)
Thubthimthong, B.; Sasaki, T.; Hane, K.
2018-02-01
GaN as a nanophotonic material has gained much attention in recent years. Using the hybrid GaN/Si platform, we report the electro-optic tuning of guided-mode resonance in a vertically coupled hybrid GaN/Si microring resonator operating in the 1.5 μm window with up to a 6 dB extinction ratio and a 1.5 MHz modulation frequency (test equipment limit). The electro-optic tuning could be optically suppressed by electron-hole-originated screening induced by an ultraviolet excitation at 325 nm. Our work may benefit in externally intervenable optical interconnects for uninterrupted secure photonic networks.
Cost-effectiveness of targeted and tailored interventions on colorectal cancer screening use.
Lairson, David R; DiCarlo, Melissa; Myers, Ronald E; Wolf, Thomas; Cocroft, James; Sifri, Randa; Rosenthal, Michael; Vernon, Sally W; Wender, Richard
2008-02-15
Colorectal cancer (CRC) screening is cost-effective but underused. The objective of this study was to determine the cost-effectiveness of targeted and tailored behavioral interventions to increase CRC screening use by conducting an economic analysis associated with a randomized trial among patients in a large, racially and ethnically diverse, urban family practice in Philadelphia. The incremental costs per unit increase were measured in individuals who were screened during the 24 months after intervention. Percent increase in screening was adjusted for baseline differences in the study groups. Each intervention arm received a targeted screening invitation letter, stool blood test (SBT) cards, informational booklet, and reminder letter. Tailored interventions incrementally added tailored messages and reminder telephone calls. Program costs of the targeted intervention were 42 dollars per participant. Additional costs of adding tailored print materials and of delivering a reminder telephone call were 150 dollars and 200 dollars per participant, respectively. The cost per additional individual screened was 319 dollars when comparing the no intervention group with the targeted intervention group. The targeted intervention was more effective and less costly than the tailored intervention. Although tailoring plus reminder telephone call was the most effective strategy, it was very costly per additional individual screened. Mailed SBT cards significantly boosted CRC screening use. However, going beyond the targeted intervention to include tailoring or tailoring plus reminder calls in the manner used in this study did not appear to be an economically attractive strategy. Cancer 2008. (c) 2007 American Cancer Society.
Double Reading in Breast Cancer Screening: Cohort Evaluation in the CO-OPS Trial.
Taylor-Phillips, Sian; Jenkinson, David; Stinton, Chris; Wallis, Matthew G; Dunn, Janet; Clarke, Aileen
2018-04-10
Purpose To investigate the effect of double readings by a second radiologist on recall rates, cancer detection, and characteristics of cancers detected in the National Health Service Breast Screening Program in England. Materials and Methods In this retrospective analysis, 805 206 women were evaluated through screening and diagnostic test results by extracting 1 year of routine data from 33 English breast screening centers. Centers used double reading of digital mammograms, with arbitration if there were discrepant interpretations. Information on reader decisions, with results of follow-up tests, were used to explore the effect of the second reader. The statistical tests used were the test for equality of proportions, the χ 2 test for independence, and the t test. Results The first reader recalled 4.76% of women (38 295 of 805 206 women; 95% confidence interval [CI]: 4.71%, 4.80%). Two readers recalled 6.19% of women in total (49 857 of 805 206 women; 95% CI: 6.14%, 6.24%), but arbitration of discordant readings reduced the recall rate to 4.08% (32 863 of 805 206 women; 95% CI: 4.04%, 4.12%; P < .001). A total of 7055 cancers were detected, of which 627 (8.89%; 95% CI: 8.22%, 9.55%; P < .001) were detected by the second reader only. These additional cancers were more likely to be ductal carcinoma in situ (30.5% [183 of 600] vs 22.0% [1344 of 6114]; P < .001), and additional invasive cancers were smaller (mean size, 14.2 vs 16.7 mm; P < .001), had fewer involved nodes, and were likely to be lower grade. Conclusion Double reading with arbitration reduces recall and increases cancer detection compared with single reading. Cancers detected only by the second reader were smaller, of lower grade, and had less nodal involvement. © RSNA, 2018.
Carrasquillo, Olveen; McCann, Sheila; Amofah, Antony; Pierre, Larry; Rodriguez, Brendaly; Alonzo, Yisel; Ilangovan, Kumar; Gonzalez, Martha; Trevil, Dinah; Byrne, Margaret M; Koru-Sengul, Tulay; Kobetz, Erin
2014-07-23
In the United States certain minority groups, such as racial/ethnic immigrant women, are less likely than non-Hispanic White women to be screened for cervical cancer. Barriers to such care include health insurance, cost, knowledge, attitudes, health literacy, and cultural norms and practices. Among the most promising approaches to increase screening in these groups are patient navigators that can link women to sources of appropriate care. Another recent promising approach is using human papilloma virus (HPV) self-sampling. In this manuscript, we describe our National Cancer Institute-sponsored study testing such approaches among immigrant minority women. The South Florida Center for the Reduction of Cancer Health Disparities (SUCCESS) is conducting a three-arm randomized trial among Hispanic, Haitian, and African American women in Miami-Dade County. Community health workers (CHW) based in each of three communities are recruiting 200 women at each site (600 total). Eligibility criteria include women aged 30-65 years who have not had a Pap smear test in the last 3 years. Prior to randomization, all women undergo a standardized structured interview. Women randomized to public health outreach, Group 1, receive culturally tailored educational materials. Women in Group 2 receive an individualized comprehensive cervical cancer CHW-led education session followed by patient navigation to obtain the Pap smear test at community-based facilities. Women in Group 3 have the option of navigation to a Pap smear test or performing HPV self-sampling. The primary outcome is self-report of completed screening through a Pap smear test or HPV self-sampling within 6 months after enrollment. SUCCESS is one of the first trials testing HPV self-sampling as a screening strategy among underserved minority women. If successful, HPV self-sampling may be an important option in community outreach programs aimed at reducing disparities in cervical cancer. Clinical Trials.gov # NCT02121548, registered April 21, 2014.
Diagnostic Value of Methylated Septin9 for Colorectal Cancer Screening: A Meta-Analysis
Yan, Shirong; Liu, Zijing; Yu, Shuang; Bao, Yixi
2016-01-01
Background Septin9 is a member of GTP-binding protein family, and is used as a predictive diagnostic index. However, it has not been widely adopted due to inconsistent results reported in the literature. The present study was performed to determine the diagnostic accuracy of methylated Septin9 (mSEPT9) for colorectal cancer (CRC) and to evaluate its utility in CRC screening. Material/Methods After reviewing relevant studies, accuracy measures (pooled sensitivity and specificity, positive/negative likelihood ratio [PLR/NLR], and diagnostic odds ratio [DOR]) were calculated for mSEPT9 in the diagnosis of CRC. Overall test performance was summarized using summary receiver operating characteristic curve analysis. Potential between-study heterogeneity was explored by use of a meta-regression model. We divided included studies into Epi proColon test and non-Epi proColon test subgroups. We compared the effects of mSEPT9 and fecal occult blood test (FOBT) for CRC screening. Results A total of 9870 subjects in 14 studies were recruited. Pooled sensitivity and specificity, PLR, NLR, DOR, and corresponding 95% confidence intervals (CI) of mSEPT9 for CRC diagnosis were 0.66 (95% CI: 0.64–0.69), 0.91 (95% CI: 0.90–0.91), 5.59 (95% CI: 4.03–7.74), 0.37 (95% CI: 0.29–0.48), and 16.79 (95% CI: 10.54–26.76), respectively. The area under the summary ROC curve (AUC) was 0.8563. The AUCs in the Epi proColon test and non-Epi proColon test for CRC diagnosis were 0.8709 and 0.7968, respectively. In head-to-head comparison, AUC of mSEPT9 and FOBT for CRC diagnosis were 0.7857 and 0.6571, respectively. Conclusions The present study demonstrates that mSEPT9 can be a good diagnostic biomarker complementary to FOBT as a screening tool for CRC. PMID:27665580
Diagnostic Value of Methylated Septin9 for Colorectal Cancer Screening: A Meta-Analysis.
Yan, Shirong; Liu, Zijing; Yu, Shuang; Bao, Yixi
2016-09-25
BACKGROUND Septin9 is a member of GTP-binding protein family, and is used as a predictive diagnostic index. However, it has not been widely adopted due to inconsistent results reported in the literature. The present study was performed to determine the diagnostic accuracy of methylated Septin9 (mSEPT9) for colorectal cancer (CRC) and to evaluate its utility in CRC screening. MATERIAL AND METHODS After reviewing relevant studies, accuracy measures (pooled sensitivity and specificity, positive/negative likelihood ratio [PLR/NLR], and diagnostic odds ratio [DOR]) were calculated for mSEPT9 in the diagnosis of CRC. Overall test performance was summarized using summary receiver operating characteristic curve analysis. Potential between-study heterogeneity was explored by use of a meta-regression model. We divided included studies into Epi proColon test and non-Epi proColon test subgroups. We compared the effects of mSEPT9 and fecal occult blood test (FOBT) for CRC screening. RESULTS A total of 9870 subjects in 14 studies were recruited. Pooled sensitivity and specificity, PLR, NLR, DOR, and corresponding 95% confidence intervals (CI) of mSEPT9 for CRC diagnosis were 0.66 (95% CI: 0.64-0.69), 0.91 (95% CI: 0.90-0.91), 5.59 (95% CI: 4.03-7.74), 0.37 (95% CI: 0.29-0.48), and 16.79 (95% CI: 10.54-26.76), respectively. The area under the summary ROC curve (AUC) was 0.8563. The AUCs in the Epi proColon test and non-Epi proColon test for CRC diagnosis were 0.8709 and 0.7968, respectively. In head-to-head comparison, AUC of mSEPT9 and FOBT for CRC diagnosis were 0.7857 and 0.6571, respectively. CONCLUSIONS The present study demonstrates that mSEPT9 can be a good diagnostic biomarker complementary to FOBT as a screening tool for CRC.
Baba, Haruna; Onanuga, Adebola
2011-01-01
Methanol extract of three Nigerian medicinal plants were screened for antimicrobial activity using modified Kirby-Bauer disc diffusion and agar dilution techniques to determine the diameters of zone of inhibition and minimum inhibitory concentrations (MIC) of the extracts respectively. The extract of each of the plants were tested against five clinical bacterial isolates comprising of two Gram-positive bacteria (Bacillus subtilis and Staphylococcus aureus) and three Gram-negative bacteria (Pseudomonas aeruginosa, Escherichia coli and Klebsiella pneumonia) organisms. All the extracts exhibited moderate to high level of antimicrobial activities against these microorganisms. Phytochemical screening of powdered plant material revealed the presence of some secondary metabolites such as alkaloids, saponins, tannins, anthraquinones and flavonoids. These Nigerian medicinal plants could be developed into cheap, safe and culturally acceptable standardized herbal products and may serve as a source of new molecules for broad-spectrum antimicrobial agents.
Understanding genetics: a primer for occupational health practice.
Wright, Lynette
2005-12-01
Because biologic diversity is essential for life, genes have developed many versions that may be further modified by interaction with other genes and with environmental factors. Polymorphic alterations of genetic material influence drug responses, predisposition or resistance to disease, and susceptibility to environmental toxicity. The occupational health professional should be aware of rapidly changing genetic tests, be able to distinguish between screening and diagnostic modalities, be able to access genetic resources to find the latest protocols, and should consider the ethical, legal, and social implications of genetic testing in the workplace.
New aspects relating to the behaviour of composites and adhesives in space
NASA Technical Reports Server (NTRS)
Carpenter, A.
1991-01-01
Some of the specialized testing procedures performed at the JPL Molecular Contamination Investigation Facility for the WideField Planetary Camera II (WFPC II) program for the screening of polymeric materials for outgassing properties are described. For WFPC II, a science performance goal of 1-percent photometric accuracy at 1470 A over an extended time (at least 30 days) has been established. Utilization of the newest technology using CCD detectors poses even more stringent requirements. Test results are presented, and data reduction and modeling techniques are discussed.
Effect of heating rate on toxicity of pyrolysis gases from some elastomers
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Kosola, K. L.; Solis, A. N.
1977-01-01
The effect of heating rate on the toxicity of the pyrolysis gases from six elastomers was investigated, using a screening test method. The elastomers were polyisoprene (natural rubber), styrene-butadiene rubber (SBR), ethylene propylene diene terpolymer (EPDM), acrylonitrile rubber, chlorosulfonated polyethylene rubber, and polychloroprene. The rising temperature and fixed temperature programs produced exactly the same rank order of materials based on time to death. Acrylonitrile rubber exhibited the greatest toxicity under these test conditions, and carbon monoxide was not found in sufficient concentrations to be the primary cause of death.
Sternberg, Eleanore D; Ng'habi, Kija R; Lyimo, Issa N; Kessy, Stella T; Farenhorst, Marit; Thomas, Matthew B; Knols, Bart G J; Mnyone, Ladslaus L
2016-09-01
Presented here are a series of preliminary experiments evaluating "eave tubes"-a technology that combines house screening with a novel method of delivering insecticides for control of malaria mosquitoes. Eave tubes were first evaluated with overnight release and recapture of mosquitoes in a screened compartment containing a hut and human sleeper. Recapture numbers were used as a proxy for overnight survival. These trials tested physical characteristics of the eave tubes (height, diameter, angle), and different active ingredients (bendiocarb, LLIN material, fungus). Eave tubes in a hut with closed eaves were also compared to an LLIN protecting a sleeper in a hut with open eaves. Eave tubes were then evaluated in a larger compartment containing a self-replicating mosquito population, vegetation, and multiple houses and cattle sheds. In this "model village", LLINs were introduced first, followed by eave tubes and associated house modifications. Initial testing suggested that tubes placed horizontally and at eave height had the biggest impact on mosquito recapture relative to respective controls. Comparison of active ingredients suggested roughly equivalent effects from bendiocarb, LLIN material, and fungal spores (although speed of kill was slower for fungus). The impact of treated netting on recapture rates ranged from 50 to 70 % reduction relative to controls. In subsequent experiments comparing bendiocarb-treated netting in eave tubes against a standard LLIN, the effect size was smaller but the eave tubes with closed eaves performed at least as well as the LLIN with open eaves. In the model village, introducing LLINs led to an approximate 60 % reduction in larval densities and 85 % reduction in indoor catches of host-seeking mosquitoes relative to pre-intervention values. Installing eave tubes and screening further reduced larval density (93 % relative to pre intervention values) and virtually eliminated indoor host-seeking mosquitoes. When the eave tubes and screening were removed, larval and adult catches recovered to pre-eave tube levels. These trials suggest that the "eave tube" package can impact overnight survival of host-seeking mosquitoes and can suppress mosquito populations, even in a complex environment. Further testing is now required to evaluate the robustness of these findings and demonstrate impact under field conditions.
Breast, prostate, and thyroid cancer screening tests and overdiagnosis.
Jung, Minsoo
The purpose of this study was to examine overdiagnosis and overtreatment related to cancer screening and to review relevant reports and studies. A comprehensive search of peer-reviewed and gray literature was conducted for relevant studies published between January 2000 and December 2015 reporting breast, prostate, and thyroid cancer screening tests and overdiagnosis. This study revealed no dichotomy on where screening would lower risk or cause overdiagnosis and overtreatment. Many screening tests did both, that is, at population level, there were both benefit (decreased disease-specific mortality) and harm (overdiagnosis and overtreatment). Therefore, we need to consider a balanced argument with citations for the potential benefits of screening along with the harms associated with screening. Although the benefits and harms can only be tested through randomized trials, important data from cohort studies, diagnostic accuracy studies, and modeling work can help define the extent of benefits and harms in the population. The health care cycle that prompt patients to undergo periodic screening tests is self-reinforcing. In most developed countries, screening test recommendations encourage periodic testing. Therefore, patients are continuing their screening. It is necessary for patients to become wise consumers of screening tests and make decisions with their physicians regarding further testing and treatments. Copyright © 2017 Elsevier Inc. All rights reserved.
Development of Intervention Materials for Individuals With Limited English Proficiency
Tu, Shin-Ping; Yip, Mei-Po; Chun, Alan; Choe, John; Bastani, Roshan; Taylor, Vicky
2013-01-01
Background According to recent US census data, 52 million people reported speaking a language other than English at home, and almost 45% of this population reported limited English proficiency (LEP). Colorectal cancer (CRC) ranks among the top 3 most common cancers for several Asian ethnic groups, yet screening remains underutilized by Asian Americans. Objectives This article describes the development of culturally and linguistically appropriate intervention materials for individuals with LEP. We discuss lessons learned from this research and implications for the translation of research into practice. Methods The Health Behavior Framework served as the conceptual model for this study, and qualitative findings guided the development of our intervention materials (a video and pamphlet). To recommend Western preventive behaviors, the research team bridged the gap between Western and Chinese values and beliefs by devoting particular attention to: (1) the target population's sociocul-tural values and health beliefs; and (2) unique linguistic features of the Chinese language. Results Key lessons learned from this study include the importance of: (1) a conceptual framework to guide intervention development; (2) incorporating sociocultural values and health beliefs into the intervention; (3) addressing and capitalizing on complex linguistics issues; (4) using qualitative methodology in cross-cultural research; and (5) contributions from a multicultural and multilingual research team. Other lessons relate to the translation of research findings into practice. We surmise that lessons learned from this study may be pertinent to the promotion of CRC screening among other patient groups with LEP and applicable to additional cancer screening tests. PMID:18725834
Compatibility of refractory materials for nuclear reactor poison control systems
NASA Technical Reports Server (NTRS)
Sinclair, J. H.
1974-01-01
Metal-clad poison rods have been considered for the control system of an advanced space power reactor concept studied at the NASA Lewis Research Center. Such control rods may be required to operate at temperatures of about 140O C. Selected poison materials (including boron carbide and the diborides of zirconium, hafnium, and tantalum) were subjected to 1000-hour screening tests in contact with candidate refractory metal cladding materials (including tungsten and alloys of tantalum, niobium, and molybdenum) to assess the compatibility of these materials combinations at the temperatures of interest. Zirconium and hafnium diborides were compatible with refractory metals at 1400 C, but boron carbide and tantalum diboride reacted with the refractory metals at this temperature. Zirconium diboride also showed promise as a reaction barrier between boron carbide and tungsten.
Ilic, Dragan; Egberts, Kristine; McKenzie, Joanne E; Risbridger, Gail; Green, Sally
2008-04-01
Patient education materials can assist patient decision making on prostate cancer screening. To explore the effectiveness of presenting health information on prostate cancer screening using video, internet, and written interventions on patient decision making, attitudes, knowledge, and screening interest. Randomized controlled trial. A total of 161 men aged over 45, who had never been screened for prostate cancer, were randomized to receive information on prostate cancer screening. Participants were assessed at baseline and 1-week postintervention for decisional conflict, screening interest, knowledge, anxiety, and decision-making preference. A total of 156 men were followed-up at 1-week postintervention. There was no statistical, or clinical, difference in mean change in decisional conflict scores between the 3 intervention groups (video vs internet -0.06 [95% CI -0.24 to 0.12]; video vs pamphlet 0.04 [95%CI -0.15 to 0.22]; internet vs pamphlet 0.10 [95%CI -0.09 to 0.28]). There was also no statistically significant difference in mean knowledge, anxiety, decision-making preference, and screening interest between the 3 intervention groups. Results from this study indicate that there are no clinically significant differences in decisional conflict when men are presented health information on prostate cancer screening via video, written materials, or the internet. Given the equivalence of the 3 methods, other factors need to be considered in deciding which method to use. Health professionals should provide patient health education materials via a method that is most convenient to the patient and their preferred learning style.
NASA Technical Reports Server (NTRS)
Banks, Bruce A.; Rutledge, Sharon K.; Paulsen, Phillip E.; Steuber, Thomas J.
1989-01-01
Atomic oxygen is the predominant species in low-Earth orbit between the altitudes of 180 and 650 km. These highly reactive atoms are a result of photodissociation of diatomic oxygen molecules from solar photons having a wavelength less than or equal to 2430A. Spacecraft in low-Earth orbit collide with atomic oxygen in the 3P ground state at impact energies of approximately 4.2 to 4.5 eV. As a consequence, organic materials previously used for high altitude geosynchronous spacecraft are severely oxidized in the low-Earth orbital environment. The evaluation of materials durability to atomic oxygen requires ground simulation of this environment to cost effectively screen materials for durability. Directed broad beam oxygen sources are necessary to evaluate potential spacecraft materials performance before and after exposure to the simulated low-Earth orbital environment. This paper presents a description of a low energy, broad oxygen ion beam source used to simulate the low-Earth orbital atomic oxygen environment. The results of materials interaction with this beam and comparison with actual in-space tests of the same meterials will be discussed. Resulting surface morphologies appear to closely replicate those observed in space tests.
BSM Delta qualification 2, volume 1
NASA Technical Reports Server (NTRS)
1994-01-01
This report, presented in three volumes, provides the results of a two-motor Delta Qualification 2 program conducted in 1993 to certify the following enhancements for incorporation into Booster Separation Motor (BSM) flight hardware: (1) vulcanized-in-place nozzle aft closure insulation; (2) new isostatic ATJ bulk graphite throat insert material; (3) adhesive EA 9394 for bonding the nozzle throat, igniter grain rod/centering insert/igniter case; (4) deletion of the igniter adapter insulator ring; (5) deletion of igniter adapter/igniter case interface RTV; and (6) deletion of Loctite from igniter retainer plate threads. The enhancements above directly resulted from (1) the BSM Total Quality Management (TQM) Team initiatives to enhance the BSM producibility, and (2) the necessity to qualify new throat insert and adhesive systems to replace existing materials that will not be available. Testing was completed at both the component and motor levels. Component testing was accomplished to screen candidate materials (e.g., throat materials, adhesive systems) and to optimize processes (e.g., aft closure insulator vulcanization approach) prior to their incorporation into the test motors. Motor testing - consisting of two motors, randomly selected by USBI's onsite quality personnel from production lot AAY, which were modified to accept the enhancements - were completed to provide the final qualification of the enhancements for incorporation into flight hardware. It is concluded that all of the enhancements herein tested are qualified to be incorporated into flight hardware for the BSM.
Cancer Screening: How Do Screening Tests Become Standard Tests?
... more groups. The people in one group (the control group ) may be given a standard screening test (if one exists) or no screening test. The ... for the human papillomavirus (HPV) and those who test negative for HPV. The ... Case-control studies Case-control studies are like cohort studies ...
Reverberatory screen for a radiant burner
Gray, Paul E.
1999-01-01
The present invention relates to porous mat gas fired radiant burner panels utilizing improved reverberatory screens. The purpose of these screens is to boost the overall radiant output of the burner relative to a burner using no screen and the same fuel-air flow rates. In one embodiment, the reverberatory screen is fabricated from ceramic composite material, which can withstand higher operating temperatures than its metallic equivalent. In another embodiment the reverberatory screen is corrugated. The corrugations add stiffness which helps to resist creep and thermally induced distortions due to temperature or thermal expansion coefficient differences. As an added benefit, it has been unexpectedly discovered that the corrugations further increase the radiant efficiency of the burner. In a preferred embodiment, the reverberatory screen is both corrugated and made from ceramic composite material.
Adler, Andreas; Geiger, Sebastian; Keil, Anne; Bias, Harald; Schatz, Philipp; deVos, Theo; Dhein, Jens; Zimmermann, Mathias; Tauber, Rudolf; Wiedenmann, Bertram
2014-10-17
Despite strong recommendations for colorectal cancer (CRC) screening, participation rates are low. Understanding factors that affect screening choices is essential to developing future screening strategies. Therefore, this study assessed patient willingness to use non-invasive stool or blood based screening tests after refusing colonoscopy. Participants were recruited during regular consultations. Demographic, health, psychological and socioeconomic factors were recorded. All subjects were advised to undergo screening by colonoscopy. Subjects who refused colonoscopy were offered a choice of non-invasive tests. Subjects who selected stool testing received a collection kit and instructions; subjects who selected plasma testing had a blood draw during the office visit. Stool samples were tested with the Hb/Hp Complex Elisa test, and blood samples were tested with the Epi proColon® 2.0 test. Patients who were positive for either were advised to have a diagnostic colonoscopy. 63 of 172 subjects were compliant to screening colonoscopy (37%). 106 of the 109 subjects who refused colonoscopy accepted an alternative non-invasive method (97%). 90 selected the Septin9 blood test (83%), 16 selected a stool test (15%) and 3 refused any test (3%). Reasons for blood test preference included convenience of an office draw, overall convenience and less time consuming procedure. 97% of subjects refusing colonoscopy accepted a non-invasive screening test of which 83% chose the Septin9 blood test. The observation that participation can be increased by offering non-invasive tests, and that a blood test is the preferred option should be validated in a prospective trial in the screening setting.
Applicability of the ParaDNA(®) Screening System to Seminal Samples.
Tribble, Nicholas D; Miller, Jamie A D; Dawnay, Nick; Duxbury, Nicola J
2015-05-01
Seminal fluid represents a common biological material recovered from sexual assault crime scenes. Such samples can be prescreened using different techniques to determine cell type and relative amount before submitting for full STR profiling. The ParaDNA(®) Screening System is a novel forensic test which identifies the presence of DNA through amplification and detection of two common STR loci (D16S539 and TH01) and the Amelogenin marker. The detection of the Y allele in samples could provide a useful tool in the triage and submission of sexual assault samples by enforcement authorities. Male template material was detected on a range of common sexual assault evidence items including cotton pillow cases, condoms, swab heads and glass surfaces and shows a detection limit of 1 in 1000 dilution of neat semen. These data indicate this technology has the potential to be a useful tool for the detection of male donor DNA in sexual assault casework. © 2015 American Academy of Forensic Sciences.
Low-cost carbon thick-film strain sensors for implantable applications
NASA Astrophysics Data System (ADS)
Gutierrez, Christian A.; Meng, Ellis
2010-09-01
The suitability of low-cost carbon thick-film strain sensors embedded within a biomedical grade silicone rubber (Silastic® MDX4-4210) for implantable applications is investigated. These sensors address the need for robust cost-effective implantable strain sensing technology for the closed loop operation of function-restoring neural prosthetic systems. Design, fabrication and characterization of the sensors are discussed in the context of the application to strain/fullness measurements of the urinary bladder as part of the neuroprosthetic treatment of lower urinary tract dysfunction. The fabrication process, utilizing off-the-shelf screen-printing materials, is convenient and cost effective while achieving resolutions down to 75 µm. This method can also be extended to produce multilayer embedded devices by superposition of different screen-printable materials. Uniaxial loading performance, temperature dependence and long-term soak testing are used to validate suitability for implantation while proof-of-concept operation (up to 40% strain) is demonstrated on a bench-top latex balloon bladder model.
Potential Explosion Hazard of Carbonaceous Nanoparticles: Screening of Allotropes
Turkevich, Leonid A.; Fernback, Joseph; Dastidar, Ashok G.; Osterberg, Paul
2016-01-01
There is a concern that engineered carbon nanoparticles, when manufactured on an industrial scale, will pose an explosion hazard. Explosion testing has been performed on 20 codes of carbonaceous powders. These include several different codes of SWCNTs (single-walled carbon nanotubes), MWCNTs (multi-walled carbon nanotubes) and CNFs (carbon nanofibers), graphene, diamond, fullerene, as well as several different control carbon blacks and graphites. Explosion screening was performed in a 20 L explosion chamber (ASTM E1226 protocol), at a concentration of 500 g/m3, using a 5 kJ ignition source. Time traces of overpressure were recorded. Samples typically exhibited overpressures of 5–7 bar, and deflagration index KSt = V1/3 (dP/dt)max ~ 10 – 80 bar-m/s, which places these materials in European Dust Explosion Class St-1. There is minimal variation between these different materials. The explosive characteristics of these carbonaceous powders are uncorrelated with primary particle size (BET specific surface area). PMID:27468178
Yıldırım, Zeynep Hoşbay; Aydınlı, Nur; Ekici, Barış; Tatlı, Burak; Çalişkan, Mine
2012-01-01
Purpose: The main object of the present study is to assess neuromotor development of high-risk infants by using three tests, and to determine inter-test concordance and the feasibility of these tests. Materials and Methods: One-hundred and nine patients aged between 0 and 6 months and identified as “high-risk infant” according to the Kliegman's criteria were enrolled to the study. Three different tests were used to assess neuromotor development of the patients: Bayley scales of infant development-II (BSID-II), Alberta infant motor scale (AIMS), and Milani Comparetti Motor Development Screening Test (MCMDST). Results: Correlation analysis was performed between pure scores of BSID-II motor scale and total scores of AIMS. These two tests were highly correlated (r:0.92). Moderate concordance was found between BSID-II and AIMS (k:0.35). Slight concordance was found between BSID-II and MCMDST; and the concordance was slight again for AIMS and MCMDST (k:0.11 and k:0.16, respectively) too. Conclusion: AIMS has a high correlation and consistency with BSID-II and can be used with routine neurological examination as it is based on observations, has few items, and requires less time to complete. PMID:22919192
Matavulj, M; Molitoris, H P
1992-12-01
The current problems with decreasing fossile resources and increasing environmental pollution by petrochemical-based plastics have stimulated investigations to find biosynthetic materials which are also biodegradable. Bacterial reserve materials such as polyhydroxyalkanoates (PHA) have been discovered to possess thermoplastic properties and can be synthesized from renewable resources. Poly-beta-hydroxybutyric acid (PHB) is at present the most promising PHA; and BIOPOL, its copolymer with poly-beta-hydroxy-valerate (PHV), is already industrially produced (ICI, UK), and used as packaging material (WELLA, FRG). According to the literature, PHA degradation has so far mainly been observed in bacteria; only under certain environmental conditions has fungal degradation of PHAs been indicated. Since fungi constitute an important part of microbial populations participating in degradation processes, a simple screening method for fungal degradation of BIOPOL, a PHA-based plastic, was developed. Several media with about 150 fungal strains from different terrestrial environments and belonging to different systematic and ecological groups were used. PHA depolymerization was tested on three PHB-based media, each with 0.1% BIOPOL or PHB homopolymer causing turbidity of the medium. The media contained either a comparatively low or high content of organic carbon (beside PHA) or were based on mineral medium with PHA as the principal source of carbon. The degradation activity was detectable due to formation of a clear halo around the colony (Petri plates) or a clear zone under the colony (test tubes).(ABSTRACT TRUNCATED AT 250 WORDS)
Adherence to multiple cancer screening tests among women living in Appalachia Ohio
Katz, Mira L.; Reiter, Paul L.; Young, Gregory S.; Pennell, Michael L.; Tatum, Cathy M.; Paskett, Electra D.
2015-01-01
Background There is a lack of information about the correlates of completing all three cancer screening tests among women living in Appalachia. Methods Cross-sectional telephone interviews were conducted (April-September 2013) among women (n=637) ages 51-75 from 12 Appalachia Ohio counties. Outcomes of within screening guidelines were verified by medical record. Multivariable logistic regression models identified correlates of being within guidelines for all three cancer screening tests. Results Screening rates were: mammography (32.1%), Pap test (36.1%), and a colorectal cancer test (30.1%). Only 8.6% of women were within guidelines for all tests. Having had a check-up in the past two years and having received a screening recommendation were significantly related to being within guidelines for all three tests (p<0.01). Participants with higher annual household incomes ($60,000+; OR=3.53, 95% CI: 1.49, 8.33) and conditions requiring regular medical visits (OR=3.16, 95% CI: 1.29, 7.74) were more likely to be within guidelines for all three screening tests. Conclusion Less than 10% of women had completed screening within guidelines for all three screening tests. Regular contact with the healthcare system and higher incomes were significant predictors of being within guidelines. Impact Within guidelines rates for the three recommended cancer screening tests is low among women in Appalachia Ohio. This finding illustrates the need for innovative interventions to improve rates of multiple cancer screening tests. PMID:26282630
Cruz Viggi, Carolina; Simonetti, Serena; Palma, Enza; Pagliaccia, Pamela; Braguglia, Camilla; Fazi, Stefano; Baronti, Silvia; Navarra, Maria Assunta; Pettiti, Ida; Koch, Christin; Harnisch, Falk; Aulenta, Federico
2017-01-01
Recent studies have suggested that addition of electrically conductive biochar particles is an effective strategy to improve the methanogenic conversion of waste organic substrates, by promoting syntrophic associations between acetogenic and methanogenic organisms based on interspecies electron transfer processes. However, the underlying fundamentals of the process are still largely speculative and, therefore, a priori identification, screening, and even design of suitable biochar materials for a given biotechnological process are not yet possible. Here, three charcoal-like products (i.e., biochars) obtained from the pyrolysis of different lignocellulosic materials, (i.e., wheat bran pellets, coppiced woodlands, and orchard pruning) were tested for their capacity to enhance methane production from a food waste fermentate. In all biochar-supplemented (25 g/L) batch experiments, the complete methanogenic conversion of fermentate volatile fatty acids proceeded at a rate that was up to 5 times higher than that observed in the unamended (or sand-supplemented) controls. Fluorescent in situ hybridization analysis coupled with confocal laser scanning microscopy revealed an intimate association between archaea and bacteria around the biochar particles and provided a clear indication that biochar also shaped the composition of the microbial consortium. Based on the application of a suite of physico-chemical and electrochemical characterization techniques, we demonstrated that the positive effect of biochar is directly related to the electron-donating capacity (EDC) of the material, but is independent of its bulk electrical conductivity and specific surface area. The latter properties were all previously hypothesized to play a major role in the biochar-mediated interspecies electron transfer process in methanogenic consortia. Collectively, these results of this study suggest that for biochar addition in anaerobic digester operation, the screening and identification of the most suitable biochar material should be based on EDC determination, via simple electrochemical tests.
Incorporating DNA Sequencing into Current Prenatal Screening Practice for Down's Syndrome
Wald, Nicholas J.; Bestwick, Jonathan P.
2013-01-01
Background Prenatal screening for Down's syndrome is performed using biochemical and ultrasound markers measured in early pregnancy such as the Integrated test using first and second trimester markers. Recently, DNA sequencing methods have been introduced on free DNA in maternal plasma, yielding a high screening performance. These methods are expensive and there is a test failure rate. We determined the screening performance of merging the Integrated test with the newer DNA techniques in a protocol that substantially reduces the cost compared with universal DNA testing and still achieves high screening performance with no test failures. Methods Published data were used to model screening performance of a protocol in which all women receive the first stage of the Integrated test at about 11 weeks of pregnancy. On the basis of this higher risk women have reflex DNA testing and lower risk women as well as those with a failed DNA test complete the Integrated test at about 15 weeks. Results The overall detection rate was 95% with a 0.1% false-positive rate if 20% of women were selected to receive DNA testing. If all women had DNA testing the detection rate would be 3 to 4 percentage points higher with a false-positive rate 30 times greater if women with failed tests were treated as positive and offered a diagnostic amniocentesis, or 3 times greater if they had a second trimester screening test (Quadruple test) and treated as positive only if this were positive. The cost per women screened would be about one-fifth, compared with universal DNA testing, if the DNA test were 20 times the cost of the Integrated test. Conclusion The proposed screening protocol achieves a high screening performance without programme test failures and at a substantially lower cost than offering all women DNA testing. PMID:23527014
McDaid, Lisa
2013-01-01
Background There is a growing number of Internet-based approaches that offer young people screening for sexually transmitted infections. Objective This paper explores young men’s views towards the barriers and facilitators of implementing an Internet-based screening approach. The study sought to consider ways in which the proposed intervention would reach and engage men across ages and socioeconomic backgrounds. Methods This qualitative study included 15 focus groups with 60 heterosexual young men (aged 16-24 years) across central Scotland, drawn across age and socioeconomic backgrounds. Focus groups began by obtaining postcode data to allocate participants to a high/low deprivation category. Focus group discussions involved exploration of men’s knowledge of chlamydia, use of technology, and views toward Internet-based screening. Men were shown sample screening invitation letters, test kits, and existing screening websites to facilitate discussions. Transcripts from audio recordings were analyzed with "Framework Analysis". Results Men’s Internet and technology use was heterogeneous in terms of individual practices, with greater use among older men (aged 20-24 years) than teenagers and some deprivation-related differences in use. We detail three themes related to barriers to successful implementation: acceptability, confidentiality and privacy concerns, and language, style, and content. These themes identify ways Internet-based screening approaches may fail to engage some men, such as by raising anxiety and failing to convey confidentiality. Men wanted screening websites to frame screening as a serious issue, rather than using humorous images and text. Participants were encouraged to reach a consensus within their groups on their broad design and style preferences for a screening website; this led to a set of common preferences that they believed were likely to engage men across age and deprivation groups and lead to greater screening uptake. Conclusions The Internet provides opportunities for re-evaluating how we deliver sexual health promotion and engage young men in screening. Interventions using such technology should focus on uptake by age and socioeconomic background. Young people should be engaged as coproducers of intervention materials and websites to ensure messages and content are framed appropriately within a fast-changing environment. Doing so may go some way to addressing the overall lower levels of testing and screening among men compared with women. PMID:24300158
Lorimer, Karen; McDaid, Lisa
2013-12-03
There is a growing number of Internet-based approaches that offer young people screening for sexually transmitted infections. This paper explores young men's views towards the barriers and facilitators of implementing an Internet-based screening approach. The study sought to consider ways in which the proposed intervention would reach and engage men across ages and socioeconomic backgrounds. This qualitative study included 15 focus groups with 60 heterosexual young men (aged 16-24 years) across central Scotland, drawn across age and socioeconomic backgrounds. Focus groups began by obtaining postcode data to allocate participants to a high/low deprivation category. Focus group discussions involved exploration of men's knowledge of chlamydia, use of technology, and views toward Internet-based screening. Men were shown sample screening invitation letters, test kits, and existing screening websites to facilitate discussions. Transcripts from audio recordings were analyzed with "Framework Analysis". Men's Internet and technology use was heterogeneous in terms of individual practices, with greater use among older men (aged 20-24 years) than teenagers and some deprivation-related differences in use. We detail three themes related to barriers to successful implementation: acceptability, confidentiality and privacy concerns, and language, style, and content. These themes identify ways Internet-based screening approaches may fail to engage some men, such as by raising anxiety and failing to convey confidentiality. Men wanted screening websites to frame screening as a serious issue, rather than using humorous images and text. Participants were encouraged to reach a consensus within their groups on their broad design and style preferences for a screening website; this led to a set of common preferences that they believed were likely to engage men across age and deprivation groups and lead to greater screening uptake. The Internet provides opportunities for re-evaluating how we deliver sexual health promotion and engage young men in screening. Interventions using such technology should focus on uptake by age and socioeconomic background. Young people should be engaged as coproducers of intervention materials and websites to ensure messages and content are framed appropriately within a fast-changing environment. Doing so may go some way to addressing the overall lower levels of testing and screening among men compared with women.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Watts, R.L.; Gurwell, W.E.; Nelson, T.A.
1979-06-01
Nine Solar Heating and Cooling of Buildings (SHACOB) designs and three Agricultural and Industrial Process Heat (AIPH) designs have been studied to identify potential future material constraints to their large scale installation and use. The nine SHACOB and three AIPH systems were screened and found to be free of serious future material constraints. The screening was carried out for each individual system design assuming 500 million m/sup 2/ of collector area installed by the year 2000. Also, two mixed design scenarios, containing equal portions of each system design, were screened. To keep these scenarios in perspective, note that a billionmore » m/sup 2/ containing a mixture of the nine SHACOB designs will yield an annual solar contribution of about 1.3 Quads or will displace about 4.2 Quads of fossil fuel used to generate electricity. For AIPH a billion square meters of the mixed designs will yield about 2.8 Quads/year. Three materials were identified that could possibly restrain the deployment of solar systems in the specific scenarios investigated. They are iron and steel, soda lime glass and polyvinyl fluoride. All three of these materials are bulk materials. No raw material supply constraints were found.« less
Motivators for women to attend cervical screening: the influential role of GPs.
O'Connor, Mairead; Murphy, Judith; Martin, Cara; O'Leary, John; Sharp, Linda
2014-08-01
Participation in organized cervical cancer screening has declined recently. While research has focussed on barriers to screening participation, less attention has been paid to what motivates women to attend. Moreover, little is known about health care provider/practitioner-level barriers and facilitators to participation. Better understanding of these issues could help inform strategies to improve participation. To explore the role of GPs in influencing women's cervical screening behaviours and investigate other motivators for women to attend for a cervical smear. Ten focus groups were conducted in Ireland, shortly before the launch of a national cervical screening programme. Discussions were audio-recorded, transcribed verbatim and transcripts were analysed thematically. GPs greatly influence women's screening behaviours and can have a positive or negative impact on women's participation in screening. Four major subthemes emerged in relation to this: the attitude of the GP; prompting by the GP; trust in the GP and women's relationships with their GP. Two main motivators to screening participation were identified: personal reasons/benefits (e.g. potential of smears to be life-saving); and practical issues/convenience. Women's also expressed desires for what they would like to see incorporated in the national screening programme (e.g. an 'out-of-hours' service). GPs can impact positively and negatively on women's cervical screening participation. Providing on-going support to GPs around their cervical screening practices is essential to maximize screening attendance. Targeted information materials that focus on the personal reasons and benefits of having smear tests could help stimulate women to participate. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Pooler, B. Dustin; Baumel, Mark J.; Cash, Brooks D.; Moawad, Fouad J.; Riddle, Mark S.; Patrick, Amy M.; Damiano, Mark; Lee, Matthew H.; Kim, David H.; del Rio, Alejandro Muñoz; Pickhardt, Perry J.
2013-01-01
OBJECTIVE Prior research indicates CT colonography (CTC) would be a cost-effective colorectal cancer (CRC) screening test if widespread availability were to increase overall CRC screening adherence rates. The primary aims of this multicenter study were to evaluate patient experience and satisfaction with CTC screening and compare preference against screening colonoscopy. MATERIALS AND METHODS A 12-question survey instrument measuring pretest choice, experience, and satisfaction was given to a consecutive cohort of adults undergoing CTC screening in three disparate screening settings: university academic center, military medical center, and community practice. The study cohort was composed of individuals voluntarily participating in clinical CTC screening programs. RESULTS A total of 1417 patients responded to the survey. The top reasons for choosing CTC for screening included “noninvasiveness” (68.0%), “avoidance of sedation/anesthesia” (63.1%), “ability to drive after the test” (49.2%), “avoidance of optical colonoscopy risks” (46.9%), and “identifying abnormalities outside the colon” (43.3%). Only 7.2% of patients reported pain during the CTC examination and only 2.5% reported greater than moderate discomfort. Of 441 patients who had experienced both CTC and optical colonoscopy, 77.1% preferred CTC and 13.8% preferred optical colonoscopy. Of all patients, 29.6% indicated that they may not have undergone optical colonoscopy screening if CTC were not available. Of all patients, 92.9% labeled their overall experience with CTC as “excellent” or “good,” and 93.0% indicated they would choose CTC for their next screening. CONCLUSION Respondents reported a very high satisfaction level with CTC, and those who had experienced both modalities indicated a preference for CTC over optical colonoscopy. These results suggest that CTC has the potential to increase adherence to CRC screening guidelines if widely available. PMID:22623549
Experimental breakdown of selected anodized aluminum samples in dilute plasmas
NASA Technical Reports Server (NTRS)
Grier, Norman T.; Domitz, Stanley
1992-01-01
Anodized aluminum samples representative of Space Station Freedom structural material were tested for electrical breakdown under space plasma conditions. In space, this potential arises across the insulating anodized coating when the spacecraft structure is driven to a negative bias relative to the external plasma potential due to plasma-surface interaction phenomena. For anodized materials used in the tests, it was found that breakdown voltage varied from 100 to 2000 volts depending on the sample. The current in the arcs depended on the sample, the capacitor, and the voltage. The level of the arc currents varied from 60 to 1000 amperes. The plasma number density varied from 3 x 10 exp 6 to 10 exp 3 ions per cc. The time between arcs increased as the number density was lowered. Corona testing of anodized samples revealed that samples with higher corona inception voltage had higher arcing inception voltages. From this it is concluded that corona testing may provide a method of screening the samples.
Is maternal plasma DNA testing impacting serum-based screening for aneuploidy in the United States?
Palomaki, Glenn E; Ashwood, Edward R; Best, Robert G; Lambert-Messerlian, Geralyn; Knight, George J
2015-11-01
We sought to determine whether tests for fetal aneuploidy based on next-generation sequencing of cell-free DNA in maternal circulation have had an impact on routine serum-based screening in the general pregnant population. We compared results from laboratory surveys in 2011 and 2014 that reported types of prenatal serum screening tests and numbers of tests performed. Testing records from two prenatal serum screening laboratories examined temporal trends in the proportion of screened women 35 years of age and older from 2008 (or 2009) to 2014. The 82 laboratory survey results available for comparison showed that 1.7 million women were screened in 2014, a 5% increase over 2011. In the two screening laboratories, the proportion of screened women age 35 and older increased for several years but then experienced reductions of 8 and 18% by mid-2014 when compared with the highest rates observed. As of 2014, maternal plasma DNA testing appears to have had only a minor impact on serum screening rates in the United States. Ongoing surveillance has the potential to determine if, and when, DNA testing begins to replace serum testing as a primary screen for Down syndrome in the United States.
Scale effects on the transverse tensile strength of graphite epoxy composites
NASA Technical Reports Server (NTRS)
Obrien, T. Kevin; Salpekar, Satish A.
1992-01-01
The influence of material volume on the transverse tensile strength of AS4/3501-6 graphite epoxy composites was investigated. Tensile tests of 90 degree laminates with 3 different widths and 5 different thicknesses were conducted. A finite element analysis was performed to determine the influence of the grip on the stress distribution in the coupons and explain the tendency for the distribution of failure locations to be skewed toward the grip. Specimens were instrumented with strain gages and extensometers to insure good alignment and to measure failure strains. Data indicated that matrix dominated strength properties varied with the volume of material that was stressed, with the strength decreasing as volume increased. Transverse strength data were used in a volumetric scaling law based on Weibull statistics to predict the strength of 90 degree laminates loaded in three point bending. Comparisons were also made between transverse strength measurements and out-of-plane interlaminar tensile strength measurements from curved beam bending tests. The significance of observed scale effects on the use of tests for material screening, quality assurance, and design allowables is discussed.
Metastatic prostate cancer in the modern era of PSA screening
Fontenot, Philip A.; Nehra, Avinash; Parker, William; Wyre, Hadley; Mirza, Moben; Duchene, David A.; Holzbeierlein, Jeffrey; Thrasher, James Brantley; Veldhuizen, Peter Van; Lee, Eugene K.
2017-01-01
ABSTRACT Introduction To characterize initial presentation and PSA screening status in a contemporary cohort of men treated for metastatic prostate cancer at our institution. Materials and methods We reviewed records of 160 men treated for metastatic prostate cancer between 2008-2014 and assessed initial presentation, categorizing patients into four groups. Groups 1 and 2 presented with localized disease and received treatment. These men suffered biochemical recurrence late (>1 year) or earlier (<1 year), respectively, and developed metastases. Groups 3 and 4 had asymptomatic and symptomatic metastases at the outset of their diagnosis. Patients with a first PSA at age 55 or younger were considered to have guideline-directed screening. Results Complete records were available on 157 men for initial presentation and 155 men for PSA screening. Groups 1, 2, 3 and 4 included 27 (17%), 7 (5%), 69 (44%) and 54 (34%) patients, respectively. Twenty (13%) patients received guideline-directed PSA screening, 5/155 (3%) patients presented with metastases prior to age 55 with their first PSA, and 130/155 (84%) had their first PSA after age 55, of which 122/130 (94%) had metastasis at the time of diagnosis. Conclusion Despite widespread screening, most men treated for metastatic prostate cancer at our institution presented with metastases rather than progressed after definitive treatment. Furthermore, 25 (16%) patients received guideline-directed PSA screening at or before age 55. These data highlight that, despite mass screening efforts, patients treated for incurable disease at our institution may not have been a result of a failed screening test, but a failure to be screened. PMID:28338310
Testing and screening for chlamydia in general practice: a cross-sectional analysis.
Thomson, Allison; Morgan, Simon; Henderson, Kim; Tapley, Amanda; Spike, Neil; Scott, John; van Driel, Mieke; Magin, Parker
2014-12-01
Chlamydia screening is widely advocated. General practice registrars are an important stage of clinical behaviour development. This study aimed to determine rates of, and factors associated with, registrars' chlamydia testing including asymptomatic screening. A cross-sectional analysis of data from Registrars Clinical Encounters in Training (ReCEnT), a cohort study of registrars' consultations. Registrars record details of 60 consecutive consultations in each GP-term of training. Outcome factors were chlamydia testing, asymptomatic screening and doctor-initiated screening. Testing occurred in 2.5% of 29,112 consultations (398 registrars) and in 5.8% of patients aged 15-25. Asymptomatic screening comprised 47.5% of chlamydia tests, and 55.6% of screening tests were doctor-initiated. Chlamydia testing was associated with female gender of doctor and patient, younger patient age, and patients new to doctor or practice. Asymptomatic screening was associated with practices where patients incur no fees, and in patients new to doctor or practice. Screening of female patients was more often doctor-initiated. GP registrars screen for chlamydia disproportionately in younger females and new patients. Our findings highlight potential opportunities to improve uptake of screening for chlamydia, including targeted education and training for registrars, campaigns targeting male patients, and addressing financial barriers to accessing screening services. © 2014 Public Health Association of Australia.
Bai, Zhi-Ru; Fei, Hong-Qiang; Li, Na; Cao, Liang; Zhang, Chen-Feng; Wang, Tuan-Jie; Ding, Gang; Wang, Zhen-Zhong; Xiao, Wei
2016-02-01
Prostaglandin (PG) E2 is an active substance in pathological and physiological mechanisms, such as inflammation and pain. The in vitro high-throughput assay for screening the inhibitors of reducing PEG2 production is a useful method for finding out antiphlogistic and analgesic candidates. The assay was based on LPS-induced PGE2 production model using a homogeneous time-resolved fluorescence(HTRF) PGE2 testing kit combined with liquid handling automation and detection instruments. The critical steps, including the cell density optimization and IC50 values determination of a positive compound, were taken to verify the stability and sensibility of the assay. Low intra-plate, inter-plate and day-to-day variability were observed in this 384-well, high-throughput format assay. Totally 5 121 samples were selected from the company's traditional Chinese medicine(TCM) material base library and used to screen PGE2 inhibitors. In this model, the cell plating density was 2 000 cells for each well; the average IC₅₀ value for positive compounds was (7.3±0.1) μmol; the Z' factor for test plates was more than 0.5 and averaged at 0.7. Among the 5 121 samples, 228 components exhibited a PGE2 production prohibition rate of more than 50%, and 23 components exhibited more than 80%. This model reached the expected standards in data stability and accuracy, indicating the reliability and authenticity of the screening results. The automated screening system was introduced to make the model fast and efficient, with a average daily screening amount exceeding 14 000 data points and provide a new model for discovering new anti-inflammatory and analgesic drug and quickly screening effective constituents of TCM in the early stage. Copyright© by the Chinese Pharmaceutical Association.
Ghanem, Maha K.; Makhlouf, Hoda A.; Agmy, Gamal R.; Imam, Hisham M. K.; Fouad, Doaa A.
2009-01-01
BACKGROUND: A prediction formula for mean pulmonary artery pressure (MPAP) using standard lung function measurement has been recently validated to screen for pulmonary hypertension (PH) in idiopathic pulmonary fibrosis (IPF) patients. OBJECTIVE: To test the usefulness of this formula as a new non invasive screening tool for PH in IPF patients. Also, to study its correlation with patients' clinical data, pulmonary function tests, arterial blood gases (ABGs) and other commonly used screening methods for PH including electrocardiogram (ECG), chest X ray (CXR), trans-thoracic echocardiography (TTE) and computerized tomography pulmonary angiography (CTPA). MATERIALS AND METHODS: Cross-sectional study of 37 IPF patients from tertiary hospital. The accuracy of MPAP estimation was assessed by examining the correlation between the predicted MPAP using the formula and PH diagnosed by other screening tools and patients' clinical signs of PH. RESULTS: There was no statistically significant difference in the prediction of PH using cut off point of 21 or 25 mm Hg (P = 0.24). The formula-predicted MPAP greater than 25 mm Hg strongly correlated in the expected direction with O2 saturation (r = −0.95, P < 0.000), partial arterial O2 tension (r = −0.71, P < 0.000), right ventricular systolic pressure measured by TTE (r = 0.6, P < 0.000) and hilar width on CXR (r = 0.31, P = 0.03). Chest symptoms, ECG and CTPA signs of PH poorly correlated with the same formula (P > 0.05). CONCLUSIONS: The prediction formula for MPAP using standard lung function measurements is a simple non invasive tool that can be used as TTE to screen for PH in IPF patients and select those who need right heart catheterization. PMID:19881164
Benning, Tim M; Dellaert, Benedict G C; Severens, Johan L; Dirksen, Carmen D
2014-07-01
Many national colorectal cancer screening campaigns have a similar structure. First, individuals are invited to take a noninvasive screening test, and, second, in the case of a positive screening test result, they are advised to undergo a more invasive follow-up test. The objective of this study was to investigate how much individuals' participation decision in noninvasive screening is affected by the presence or absence of detailed information about invasive follow-up testing and how this effect varies over screening tests. We used a labeled discrete choice experiment of three noninvasive colorectal cancer screening types with two versions that did or did not present respondents with detailed information about the possible invasive follow-up test (i.e., colonoscopy) and its procedure. We used data from 631 Dutch respondents aged 55 to 75 years. Each respondent received only one of the two versions (N = 310 for the invasive follow-up test information specification version, and N = 321 for the no-information specification version). Mixed logit model results show that detailed information about the invasive follow-up test negatively affects screening participation decisions. This effect can be explained mainly by a decrease in choice shares for the most preferred screening test (a combined stool and blood sample test). Choice share simulations based on the discrete choice experiment indicated that presenting invasive follow-up test information decreases screening participation by 4.79%. Detailed information about the invasive follow-up test has a negative effect on individuals' screening participation decisions in noninvasive colorectal cancer screening campaigns. This result poses new challenges for policymakers who aim not only to increase uptake but also to provide full disclosure to potential screening participants. Copyright © 2014 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Abnormal Cervical Cancer Screening Test Results
... FAQ187 GYNECOLOGIC PROBLEMS Abnormal Cervical Cancer Screening Test Results • What is cervical cancer screening? • What causes abnormal cervical cancer screening test results? • What is the difference between the terms cervical ...
Preliminary test data using the MOS DRO with Si:In detector material
NASA Technical Reports Server (NTRS)
Fowler, A. M.; Britt, J. P.; Joyce, R. R.; Probst, R. G.; Gates, J. L.
1986-01-01
The initial testing performed on the Hughes Metal Oxide Semiconductor Direct Readout (MOS DRO) with a Si:In extrinsic infrared array is described. The testing to date was of a screening nature and the results are primarily qualitative rather than quantitative. At a later date the performance optimization phase will be initiated. An encouraging result is that this response is strongly dependent on the detector temperature, to the extent that thermal transients introduced during the chip readout will affect the performance. A responsivity of 1 A/W at 2.2 microns with a bias of 15 volts, which is well below what is optimum bias, was obtained.
Osorio, Veronica; Grininger, Angelika; Richter, Alexander; Bergmair, Johannes; Pyerin, Michael; Washüttl, Michael; Tacker, Manfred
2014-01-01
Endocrine active substances (EAS) show structural similarities to natural hormones and are suspected to affect the human endocrine system by inducing hormone dependent effects. Recent studies with in vitro tests suggest that EAS can leach from packaging into food and may therefore pose a risk to human health. Sample migrates from food contact materials were tested for estrogen and androgen agonists and antagonists with different commonly used in vitro tests. Additionally, chemical trace analysis by GC-MS and HPLC-MS was used to identify potential hormone active substances in sample migrates. A GC-MS method to screen migrates for 29 known or potential endocrine active substances was established and validated. Samples were migrated according to EC 10/2011, concentrated by solid phase extraction and tested with estrogen and androgen responsive reporter gene assays based on yeast cells (YES and YAS) or human osteoblast cells (ERα and AR CALUX). A high level of agreement between the different bioassays could be observed by screening for estrogen agonists. Four out of 18 samples tested showed an estrogen activity in a similar range in both, YES and ERα CALUX. Two more samples tested positive in ERα CALUX due to the lower limits of detection in this assay. Androgen agonists could not be detected in any of the tested samples, neither with YAS nor with AR CALUX. When testing for antagonists, significant differences between yeast and human cell-based bioassays were noticed. Using YES and YAS many samples showed a strong antagonistic activity which was not observed using human cell-based CALUX assays. By GC-MS, some known or supposed EAS were identified in sample migrates that showed a biological activity in the in vitro tests. However, no firm conclusions about the sources of the observed hormone activity could be obtained from the chemical results. PMID:25000404
NASA Technical Reports Server (NTRS)
Collins, Timothy J.; Congdon, William M.; Smeltzer, Stanley S.; Whitley, Karen S.
2005-01-01
The next generation of planetary exploration vehicles will rely heavily on robust aero-assist technologies, especially those that include aerocapture. This paper provides an overview of an ongoing development program, led by NASA Langley Research Center (LaRC) and aimed at introducing high-temperature structures, adhesives, and advanced thermal protection system (TPS) materials into the aeroshell design process. The purpose of this work is to demonstrate TPS materials that can withstand the higher heating rates of NASA's next generation planetary missions, and to validate high-temperature structures and adhesives that can reduce required TPS thickness and total aeroshell mass, thus allowing for larger science payloads. The effort described consists of parallel work in several advanced aeroshell technology areas. The areas of work include high-temperature adhesives, high-temperature composite materials, advanced ablator (TPS) materials, sub-scale demonstration test articles, and aeroshell modeling and analysis. The status of screening test results for a broad selection of available higher-temperature adhesives is presented. It appears that at least one (and perhaps a few) adhesives have working temperatures ranging from 315-400 C (600-750 F), and are suitable for TPS-to-structure bondline temperatures that are significantly above the traditional allowable of 250 C (482 F). The status of mechanical testing of advanced high-temperature composite materials is also summarized. To date, these tests indicate the potential for good material performance at temperatures of at least 600 F. Application of these materials and adhesives to aeroshell systems that incorporate advanced TPS materials may reduce aeroshell TPS mass by 15% - 30%. A brief outline is given of work scheduled for completion in 2006 that will include fabrication and testing of large panels and subscale aeroshell test articles at the Solar-Tower Test Facility located at Kirtland AFB and operated by Sandia National Laboratories. These tests are designed to validate aeroshell manufacturability using advanced material systems, and to demonstrate the maintenance of bondline integrity at realistically high temperatures and heating rates. Finally, a status is given of ongoing aeroshell modeling and analysis efforts which will be used to correlate with experimental testing, and to provide a reliable means of extrapolating to performance under actual flight conditions. The modeling and analysis effort includes a parallel series of experimental tests to determine TSP thermal expansion and other mechanical properties which are required for input to the analysis models.
Creep Property Characterization of Potential Brayton Cycle Impeller and Duct Materials
NASA Astrophysics Data System (ADS)
Gabb, Timothy P.; Gayda, John; Garg, Anita
2007-01-01
Cast superalloys have potential applications in space as impellers within closed-loop Brayton cycle nuclear power generation systems. Likewise wrought superalloys are good candidates for ducts and heat exchangers transporting the inert working gas in a Brayton-based power plant. Two cast superalloys, Mar-M247LC and IN792, and a NASA GRC powder metallurgy superalloy, LSHR, have been screened to compare their respective capabilities for impeller applications. Mar-M247LC has been selected for additional long term evaluations. Initial tests in helium indicate this inert environment may debit long term creep resistance of this alloy. Several wrought superalloys including Hastelloy® X, Inconel® 617, Inconel® 740, Nimonic® 263, Incoloy® MA956, and Haynes 230 are also being screened to compare their capabilities for duct applications. Haynes 230 has been selected for additional long term evaluations. Initial tests in helium are just underway for this alloy. These proposed applications would require sufficient strength and creep resistance for long term service at temperatures up to 1200 K, with service times to 100,000 h or more. Therefore, long term microstructural stability is also being screened.
Creep Property Characterization of Potential Brayton Cycle Impeller and Duct Materials
NASA Technical Reports Server (NTRS)
Gabb, Timothy P.; Gayda, john; Garg, Anita
2007-01-01
Cast superalloys have potential applications in space as impellers within closed-loop Brayton cycle nuclear power generation systems. Likewise wrought superalloys are good candidates for ducts and heat exchangers transporting the inert working gas in a Brayton-based power plant. Two cast superalloys, Mar-M247LC and IN792, and a NASA GRC powder metallurgy superalloy, LSHR, have been screened to compare their respective capabilities for impeller applications. Mar-M247LC has been selected for additional long term evaluations. Initial tests in helium indicate this inert environment may debit long term creep resistance of this alloy. Several wrought superalloys including Hastelloy(Registered TradeMark) X, Inconel(Registered TradeMark) 617, Inconel(Registered TradeMark) 740, Nimonic(Registered TradeMark) 263, Incoloy(Registered TradeMark) MA956, and Haynes 230 are also being screened to compare their capabilities for duct applications. Haynes 230 has been selected for additional long term evaluations. Initial tests in helium are just underway for this alloy. These proposed applications would require sufficient strength and creep resistance for long term service at temperatures up to 1200 K, with service times to 100,000 h or more. Therefore, long term microstructural stability is also being screened.
Kim, Seon Young; Kim, Hyunjin; Park, Yeongchun; Lim, Jinsook; Kim, Jimyung; Koo, Sun Hoe; Kwon, Gye Cheol
2017-06-01
On-site drugs of abuse testing devices have undergone continuous improvement. We evaluated three devices with different designs: an automated reader, the Multi-Drug Screen Test Device with DxLINK (DxLINK; Innovacon, Alere, San Diego, USA) and two colorimetric immunoassays, the One Step Multi-Line Screen Panel with Integrated E-Z Split Key Cup II (E-Z Cup; Innovacon, Alere) and the One Step Multi-Drug Screen Panel card (Multi4 card; Alere, Abon Biopharm, Hangzhou, China). Eleven drugs [amphetamine, secobarbital, oxazepam, buprenorphine, benzoylecgonine, methylenedioxymethamphetamine (MDMA), 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC), methamphetamine, methadone, morphine and nortriptyline] were tested using the DxLINK and E-Z Cup. Four drugs (benzoylecgonine, THC, methamphetamine and morphine) were tested using the Multi4 card using control materials (Detectabuse Stat-Skreen; Biochemical Diagnostics, Edgewood, NY, USA). The concentrations (-50%, -25%, +25%, +50% and 3× cut-off values) of the control materials were confirmed by mass spectrometry. Concordance rates were calculated around cut-offs. All devices showed high overall agreement rates of >90% with a few exceptions: the DxLINK exhibited lower sensitivity for benzoylecgonine, methadone and nortriptyline (60% and 30%, 92% and 40%, and 96% and 60% sensitivity at +50% and +25% cut-off levels, respectively). The E-Z Cup exhibited lower sensitivity for oxazepam and nortriptyline (97% and 50%, and 97% and 40% sensitivity at +50% and +25% cut-off levels, respectively). We additionally evaluated test-band color by visual inspection using a standard color-scale card. When detailed color criteria for determination of positivity were applied for the E-Z Cup, using slightly less stringent criteria, oxazepam, buprenorphine, MDMA and nortriptyline showed increases in sensitivity from 70-80% to 90-100%, all with a specificity above 98%. Overall, all devices exhibited satisfactory performance at ±50% cut-off levels for commonly used drugs, with the exception of lower sensitivity for cocaine testing for DxLINK. Careful evaluation of devices and elaborate calibration of visual interpretation for determining positivity may help improve the performance of these devices. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Senore, Carlo; Mandel, Jack S.; Allison, James E.; Atkin, Wendy S.; Benamouzig, Robert; Bossuyt, Patrick M. M.; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P.; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H.; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A.; O'Morain, Colm A.; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E.; Seaman, Helen E.; Steele, Robert J. C.; Sung, Joseph J. Y.; Winawer, Sidney J.
2016-01-01
BACKGROUND New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. METHODS A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. RESULTS Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention‐to‐screen basis, including acceptability, is essential. Cancer‐specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac‐based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4‐phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention‐to‐screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true‐positive and false‐positive rates, and the number needed to colonoscope to detect a target lesion. CONCLUSIONS New screening tests can be evaluated efficiently by this stepwise comparative approach. Cancer 2016;122:826–39. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society. PMID:26828588
Young, Graeme P; Senore, Carlo; Mandel, Jack S; Allison, James E; Atkin, Wendy S; Benamouzig, Robert; Bossuyt, Patrick M M; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A; O'Morain, Colm A; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E; Seaman, Helen E; Steele, Robert J C; Sung, Joseph J Y; Winawer, Sidney J
2016-03-15
New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention-to-screen basis, including acceptability, is essential. Cancer-specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac-based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4-phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention-to-screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true-positive and false-positive rates, and the number needed to colonoscope to detect a target lesion. New screening tests can be evaluated efficiently by this stepwise comparative approach. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Very, F.; Rosenkrantz, E.; Combette, P.
The development of advanced instrumentation for in-pile experiments in Material Testing Reactor constitutes a main goal for the improvement of the nuclear fuel behavior knowledge. An acoustic method for fission gas release detection was tested with success during a first experiment called REMORA 3 in 2010 and 2011, and the results were used to differentiate helium and fission gas release kinetics under transient operating conditions. This experiment was lead at OSIRIS reactor (CEA Saclay, France). The maximal temperature on the sensor during the irradiation was about 150 deg. C. In this paper we present a thick film transducer produce bymore » screen printing process. The screen printing of piezoelectric offers a wide range of possible applications for the development of acoustic sensors and piezoelectric structure for measurements in high temperature environment. We firstly produced a Lead Zirconate Titanate (PZT) based paste composed of Pz27 powder from Ferroperm, CF7575 glass, and organic solvent ESL 400. Likewise a Bismuth Titanate based paste synthesized in our laboratory was produced. With these inks we produced thick film up to 130 μm by screen printing process. Material properties characterizations of these thick-film resonators are essential for device design and applications. The piezoelectric coefficients d33 and pyro-electric P(T) coefficient are investigated. The highest P(T) and d33 are respectively 80 μC.m{sup -2}.K{sup -1} and 130 μC.N{sup -1} for the PZT transducer -which validates the fabrication process-. In view of the development of this transducer oriented for high temperature and irradiation environment, we investigated the electrical properties of the transducers for different ranges of frequencies and temperature - from 20 Hz up to 40 MHz between 30 and 400 deg. C. We highlight the evolution of the impedance response and piezoelectric parameters of screen printed piezoelectric structures on alumina. Shortly an irradiation will be realized in order to investigate their reliability towards neutron fluence. (authors)« less
Apitz, Sabine E; Agius, Suzanne
2017-11-01
The effects of possible changes to the Canadian 2-tiered assessment framework for dredged material based on outcomes of the 2006 Contaminated Dredged Material Management Decisions Workshop (CDMMD) are evaluated. Expanding on the "data mining" approach described in a previous paper, which focused solely on chemical lines of evidence, the efficacy of Tier 1 approaches (increases to the number of chemical analytes, use of mean hazard quotients, and the use of a screening bioassay) in predicting toxicity are evaluated. Results suggest value in additional work to evaluate the following areas: 1) further expanding minimum chemical requirements, 2) using more advanced approaches for chemical interpretation, and 3) using a screening-level bioassay (e.g., Canadian solid-phase photoluminescent bacteria test) to determine whether it would complement Tier 1 chemistry as well as or better than the solvent-based Microtox™ test method evaluated in the present study. Integr Environ Assess Manag 2017;13:1072-1085. © 2017 The Authors. Integrated Environmental Assessment and Management published by Wiley Periodicals, Inc. on behalf of Society of Environmental Toxicology & Chemistry (SETAC). © 2017 The Authors. Integrated Environmental Assessment and Management published by Wiley Periodicals, Inc. on behalf of Society of Environmental Toxicology & Chemistry (SETAC).
A new screening test for toxicity testing of dental materials.
Pelka, M; Danzl, C; Distler, W; Petschelt, A
2000-07-01
The development of a micro plate assay for cytotoxicity testing of dental materials based on a bioassay using brine shrimp larvae (artemia salina) as sensitive organisms. Brine shrimp larvae are commonly used for cytotoxicity assays in pharmacology. These larvae are sensitive to toxic substances. The ratio between dead larvae (no motility) and living larvae (high motility) in comparison to a control without any toxic substances is used to estimate the toxicity of the test solutions. The test materials (Arabesk((R)), Solitaire((R)), Pertac((R)) II, Tetric((R)), Herculite((R)) and the compomer materials Dyract((R)), Hytac((R)), Compoglass((R))) were polymerized and consecutively milled. After incubation of 1g in 4ml distilled water at 37 degrees C for 48h, the solid materials were separated by centrifugation. The solutions were equibrilated with NaCl to a salt content of 25g/l. Aliquots of 200microl were distributed in eight micro wells and 50microl of a artemia salina containing (n=8-14) solution were added to each well. As controls eight wells with 250microl salt solution containing a comparable number of brine shrimp were used. At baseline, after 2, 5, 24 and 48h, the dead shrimp were counted using a stereo microscope. Finally all shrimps were sacrificed using Na-acid (5%) and counted to get the number of shrimps per well. All compomers and Solitaire caused 100% brine shrimp lethality after 24h and showed significantly (p<0.01, signed rank test) higher toxicities than the remaining composites. With the exception of Pertac II, all composites showed significantly higher toxic values than the control. Pertac II did not show any differences from the controls used. This new technique has some advantages for toxicity testing of restorative materials, because it can quickly be carried out at low costs. The disadvantage is the high quantity of material used and the low sensitivity.
BSA Delta Qualification 2, volume 3, book 1
NASA Technical Reports Server (NTRS)
1994-01-01
This report, presented in three volumes, provides the results of a two-motor Delta Qualification 2 program conducted in 1993 to certify the following enhancements for incorporation into booster separation motor (BSM) flight hardware: vulcanized-in-place nozzle aft closure insulation; new iso-static ATJ bulk graphite throat insert material; adhesive EA 9394 for bonding the nozzle throat, igniter grain rod/centering insert/igniter case; deletion of the igniter adapter insulator ring; deletion of the igniter adapter/igniter case interface RTV; and deletion of Loctite from igniter retainer plate threads. The enhancements above directly resulted from (1) the BSM total quality management (TQM) team initiatives to enhance the BSM producibility, and (2) the necessity to qualify new throat insert and adhesive systems to replace existing materials that will not be available. Testing was completed at both the component and motor levels. Component testing was accomplished to screen candidate materials (e.g., throat materials, adhesive systems) and to optimize processes (e.g., aft closure insulator vulcanization approach) prior to their incorporation into the test motors. Motor tests -- consisting of two motors, randomly selected by USBI's on-site quality personnel from production lot AAY, which were modified to accept the enhancements -- were completed to provide the final qualification of the enhancements for incorporation into flight hardware. Volume 3 book 1 provides supporting documentation to the analyses and plans of testing the two Delta Qualification units including thermal cycling planning/data acceptance records, environmental test procedures and pretest temperature conditioning history, Delta Qualification test plan, and specification SE0837 -- mix acceptance test specification.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blau, Peter J.; Cooley, Kevin M.; Kirkham, Melanie J.
This final report summarizes experimental and analytical work performed under an agreement between the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Office of Transportation Technologies, and UT-Battelle LLC. The project was directed by Jerry Gibbs, of the U.S. Department of Energy’s Propulsion Materials Program, with management by D. P. Stinton and J. A. Haynes of ORNL. Participants included Peter J. Blau (Principal Investigator), Kevin M. Cooley (senior technician), Melanie J. Kirkham (materials scientist) of the Materials Science and Technology Division or ORNL, and Dinesh G. Bansal, a post doctoral fellow employed by Oak Ridge Associated Universitiesmore » (ORAU) and who, at the time of this writing, is an engineer with Cummins, Inc. This report covers a three-year effort that involved two stages. In the first stage, and after a review of the literature and discussions with surface treatment experts, a series of candidate alloys and surface treatments for titanium alloy (Ti-6Al-4V) was selected for initial screening. After pre-screening using an ASTM standard test method, the more promising surface treatments were tested in Phase 2 using a variable loading apparatus that was designed and built to simulate the changing load patterns in a typical connecting rod bearing. Information on load profiles from the literature was supplemented with the help of T.C. Chen and Howard Savage of Cummins, Inc. Considering the dynamic and evolving nature of materials technology, this report presents a snapshot of commercial and experimental bearing surface technologies for titanium alloys that were available during the period of this work. Undoubtedly, further improvements in surface engineering methods for titanium will evolve.« less
Separator development and testing of nickel-hydrogen cells
NASA Technical Reports Server (NTRS)
Gonzalez-Sanabria, O. D.; Manzo, M. A.
1984-01-01
The components, design, and operating characteristics of Ni-H2 cells batteries were improved. A separator development program was designed to develop a separator that is resistant to penetration by oxygen and loose active material from then nickel electrode, while retraining the required chemical and thermal stability, reservoir capability, and high ionic conductivity. The performance of the separators in terms of cell operating voltage was to at least match that of state-of-the-art separators while eliminating the separator problems. The separators were submitted to initial screening tests and those which successfully completed the tests were built into Ni-H2 cells for short term testing. The separators with the best performance are tested for long term performance and life.
Mathews, Miya Gugulethu; Ajayi, Oyemitan Idris; Opeoluwa, Oyedeji Oyehan; Oluwatobi, Oluwafemi Samuel; Benedicta N, Nkeh-Chungag; Phindile, Songca Sandile; Oyedeji; Omowumi, Adebola
2016-01-01
Background: Pentanisia prunelloides is a medicinal plant widely used to remedy various ailments including infections, fever and rheumatism in Eastern Cape Province of South Africa. There is scanty report on the phytochemical and biological properties of the plant; hence various solvent extracts of the dried plant materials were phytochemically screened, and its aqueous extract evaluated for acute toxicity effect, analgesic and antiinflammatory properties in rodents. Methods and Materials: Different extracts of both leaf and rhizome were obtained separately with ethanol, methanol and water. Portions of the filtrate were used for qualitative screening of secondary metabolites and remaining portions were concentrated and dried. Dried grounded leaf and rhizome of the plant were also used for quantitative screening for some major components. The aqueous extract of the leaf and rhizome were used for acute toxicity (LD50) test, antiinflammatory and analgesic activities in rodents. Results: The qualitative phytochemical screening showed the presence of several phytoconstituents with saponins, flavonoids and alkaloids constituting highest constituents in the leaf and rhizome. The LD50: of the aqueous extracts (from leaf or rhizome) was found to be ≥5000 mg/kg orally. The leaf and rhizome aqueous extract (250-500 mg/kg) significantly (p<0.01) reduced egg albumin-induced paw oedema and paw licking in mice induced by formalin, signifying antinociceptive and antiinflammatory activities respectively. Conclusion: It is concluded that the leaf and rhizome of P. prunelloides are rich in various phytochemicals which could be associated with their medicinal uses. The aqueous leaf and rhizome extracts are similarly non-toxic orally, showed antiinflammatory and analgesic potentials thus rationalizing its use in folkloric medicine. PMID:28480377
Busquet, François; Nagel, Roland; von Landenberg, Friedrich; Mueller, Stefan O; Huebler, Nicole; Broschard, Thomas H
2008-07-01
The assessment of teratogenic effects of chemicals is generally performed using in vivo teratogenicity assays, for example, in rats or rabbits. We have developed an in vitro teratogenicity assay using the zebrafish Danio rerio embryo combined with an exogenous mammalian metabolic activation system (MAS), able to biotransform proteratogenic compounds. Cyclophosphamide (CPA) and ethanol were used as proteratogens to test the efficiency of this assay. Briefly, the zebrafish embryos were cocultured at 2 hpf (hours postfertilization) with the test material at varying concentrations, induced male rat liver microsomes and nicotinamide adenine dinucleotide phosphate (reduced) for 60 min at 32 degrees C under moderate agitation in Tris-buffer. The negative control (test material alone) and the MAS control (MAS alone) were incubated in parallel. For each test group, 20 eggs were used for statistical robustness. Afterward fish embryos were transferred individually into 24-well plates filled with fish medium for 48 h at 26 degrees C with a 12-h light cycle. Teratogenicity was scored after 24 and 48 hpf using morphological endpoints. No teratogenic effects were observed in fish embryos exposed to the proteratogens alone, that is, without metabolic activation. In contrast, CPA and ethanol induced abnormalities in fish embryos when coincubated with microsomes. The severity of malformations increased with increasing concentrations of the proteratogens. We conclude that the application of microsomes will improve and refine the D. rerio teratogenicity assay as a predictive and valuable alternative method to screen teratogenic substances.
Abrasion Testing of Candidate Outer Layer Fabrics for Lunar EVA Space Suits
NASA Technical Reports Server (NTRS)
Mitchell, Kathryn
2009-01-01
During the Apollo program, the space suit outer layer fabrics were severely abraded after just a few Extravehicular Activities (EVAs). For example, the Apollo 12 commander reported abrasive wear on the boots, which penetrated the outer layer fabric into the thermal protection layers after less than eight hours of surface operations. Current plans for the Constellation Space Suit Element require the space suits to support hundreds of hours of EVA on the Lunar surface, creating a challenge for space suit designers to utilize materials advances made over the last forty years and improve upon the space suit fabrics used in the Apollo program. A test methodology has been developed by the NASA Johnson Space Center Crew and Thermal Systems Division for establishing comparative abrasion wear characteristics between various candidate space suit outer layer fabrics. The abrasion test method incorporates a large rotary drum tumbler with rocks and loose lunar simulant material to induce abrasion in fabric test cylinder elements, representative of what might occur during long term planetary surface EVAs. Preliminary materials screening activities were conducted to determine the degree of wear on representative space suit outer layer materials and the corresponding dust permeation encountered between subsequent sub-layers of thermal protective materials when exposed to a simulated worst case eight hour EVA. The test method was used to provide a preliminary evaluation of four candidate outer layer fabrics for future planetary surface space suit applications. This paper provides a review of previous abrasion studies on space suit fabrics, details the methodologies used for abrasion testing in this particular study, shares the results of the testing, and provides recommendations for future work.
Abrasion Testing of Candidate Outer Layer Fabrics for Lunar EVA Space Suits
NASA Technical Reports Server (NTRS)
Mitchell, Kathryn C.
2010-01-01
During the Apollo program, the space suit outer layer fabrics were badly abraded after just a few Extravehicular Activities (EVAs). For example, the Apollo 12 commander reported abrasive wear on the boots, which penetrated the outer layer fabric into the thermal protection layers after less than eight hours of surface operations. Current plans for the Constellation Space Suit Element require the space suits to support hundreds of hours of EVA on the Lunar surface, creating a challenge for space suit designers to utilize materials advances made over the last forty years and improve upon the space suit fabrics used in the Apollo program. A test methodology has been developed by the NASA Johnson Space Center Crew and Thermal Systems Division for establishing comparative abrasion wear characteristics between various candidate space suit outer layer fabrics. The abrasion test method incorporates a large rotary drum tumbler with rocks and loose lunar simulant material to induce abrasion in fabric test cylinder elements, representative of what might occur during long term planetary surface EVAs. Preliminary materials screening activities were conducted to determine the degree of wear on representative space suit outer layer materials and the corresponding dust permeation encountered between subsequent sub -layers of thermal protective materials when exposed to a simulated worst case eight hour EVA. The test method was used to provide a preliminary evaluation of four candidate outer layer fabrics for future planetary surface space suit applications. This Paper provides a review of previous abrasion studies on space suit fabrics, details the methodologies used for abrasion testing in this particular study, and shares the results and conclusions of the testing.
Develop Silicone Encapsulation Systems for Terrestrial Silicon Solar Arrays
NASA Technical Reports Server (NTRS)
1979-01-01
The results for Task 3 of the Low Cost Solar Array Project are presented. Task 3 is directed toward the development of a cost effective encapsulating system for photovoltaic modules using silicon based materials. The technical approach of the contract effort is divided into four special tasks: (1) technology review; (2) generation of concepts for screening and processing silicon encapsulation systems; (3) assessment of encapsulation concepts; and (4) evaluation of encapsulation concepts. The candidate silicon materials are reviewed. The silicon and modified silicon resins were chosen on the basis of similarity to materials with known weatherability, cost, initial tangential modulus, accelerated dirt pick-up test results and the ratio of the content of organic phenyl substitution of methyl substitution on the backbone of the silicon resin.
Sukumar, Gautham Melur; Kupatira, Kowshik; Gururaj, G.
2015-01-01
Background: Noncommunicable disease (NCDs), psychological, substance use disorders, and stress-related issues have been less understood in Indian industrial settings. Systems for screening and early identification of the above have not been integrated in workplaces, nor there is a strong regulatory backing for the same. Aim: To explore the feasibility of integrating mental health and select NCD risk factor screening with the periodical medical examination of employees. To identify proportion of employees with select NCD risk factors and symptoms suggestive of mental health problems. Settings and Design: Around 10% of employees from a leading motor industry in Bangalore, (706) participated in this cross-sectional voluntary screening program. Materials and Methods: This screening was conducted as a part of their annual medical examination. A mixed method of self-report and interview administered technique was adopted for the same. Statistical Analysis: Descriptive statistical methods (proportions, median, mean, and standard deviation (SD)) and Chi-square test of significance. Results and Conclusions: Screening revealed the following; tobacco use (18%), alcohol use (57%), perceived work stress (10%), and obesity (3%). Nearly 23% screened positive for psychological distress. Time consumed for this assessment was 1–5 min. Initial attempts point out that it is feasible to integrate screening for mental health, substance use, and NCD risk factors in periodic medical examination using a combination of self-report and interview-administered method, though further detailed assessments for confirmation is necessary. PMID:26023267
NASA Technical Reports Server (NTRS)
Cook, R. V.; Fairbourn, M. W.; Wendel, G. M.
2000-01-01
Thiokol Corporation and NASA MSFC are jointly developing a replacement for North American Rayon Corporation (NARC) Aerospace Grade Rayon (1650/720 continuous filament), the precursor for the Carbon Cloth Phenolic (CCP) ablatives used in the Space Shuttle Reusable Solid Rocket Motor (RSRM) Nozzles. NARC discontinued production of Aerospace Grade Rayon in September 1997. NASA maintains a stockpile of NARC Rayon to support RSRM production through the summer of 2005. The program plan for selection and qualification of a replacement for NARC rayon was approved in August 1998. Screening activities began in February 1999. The intent of this paper is to provide a summary of the data generated during the screening phase of the NARC Rayon Replacement Program. Twelve cellulose based fibers (rayon and lyocell) were evaluated. These fibers were supplied by three independent vendors. Many of these fibers were carbonized by two independent carbonizers. Each candidate was tested according to standard acceptance test methods at each step of the manufacturing process. Additional testing was performed with the candidate CCPS, including hot fire tests, Process studies and mechanical and thermal characterization. Six of the twelve fiber candidates tested were dropped at the conclusion of Phase 1. The reasons for the elimination of these candidates included; difficulties in processing the material in the whitegoods, carbon and CCP forms; poor composite mechanical performance; and future availability concerns. The remaining six fibers demonstrated enough promise to merit continued evaluation and optimization of the CCP fabrication process. Note: Certain CCP data falls under the restrictions of US export laws, (ITAR, etc.) and will not be included in this paper.
42 CFR 410.17 - Cardiovascular disease screening tests.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 2 2011-10-01 2011-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...
42 CFR 410.17 - Cardiovascular disease screening tests.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 2 2012-10-01 2012-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...
42 CFR 410.17 - Cardiovascular disease screening tests.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 2 2013-10-01 2013-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...
42 CFR 410.17 - Cardiovascular disease screening tests.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 2 2014-10-01 2014-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...
42 CFR 410.17 - Cardiovascular disease screening tests.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...
Uptake of prenatal diagnostic testing and the effectiveness of prenatal screening for Down syndrome.
Jaques, Alice M; Collins, Veronica R; Muggli, Evelyne E; Amor, David J; Francis, Ivan; Sheffield, Leslie J; Halliday, Jane L
2010-06-01
To map prenatal screening and diagnostic testing pathways in Victorian pregnant women during 2003 to 2004; measure the impact of prenatal diagnostic testing uptake on the effectiveness of prenatal screening for Down syndrome; and assess factors influencing uptake of diagnostic testing following screening. State-wide data collections of prenatal screening and diagnostic tests were linked to all Victorian births and pregnancy terminations for birth defects. Overall, 52% of women had a prenatal test (65 692/126 305); screening (44.9%), diagnostic testing (3.9%), or both (3.2%). Uptake of diagnostic testing was 71.4% (2390/3349) after an increased risk screen result, and 2.5% (1381/54 286) after a low risk result. Variation in uptake of diagnostic testing reduced the effectiveness of the screening program by 11.2%: from 87.4% (sensitivity - 125/143) to 76.2% (prenatal diagnoses of Down syndrome - 109/143). In both the increased and low risk groups, uptake was influenced by absolute numerical risk, as well as by the change in numerical risk from a priori risk. This comprehensive follow-up demonstrates clearly that numerical risk is being used to aid in decision making about confirmatory diagnostic testing. Collectively, these fundamental individual decisions will impact on the overall effectiveness of screening programmes for Down syndrome.
Health Literacy and Cancer Prevention: Two New Instruments to Assess Comprehension
Mazor, Kathleen M.; Roblin, Douglas W.; Williams, Andrew E.; Greene, Sarah M.; Gaglio, Bridget; Field, Terry S.; Costanza, Mary E.; Han, Paul K. J.; Saccoccio, Laura; Calvi, Josephine; Cove, Erica; Cowan, Rebecca
2012-01-01
Objectives Ability to understand spoken health information is an important facet of health literacy, but to date, no instrument has been available to quantify patients’ ability in this area. We sought to develop a test to assess comprehension of spoken health messages related to cancer prevention and screening to fill this gap, and a complementary test of comprehension of written health messages. Methods We used the Sentence Verification Technique to write items based on realistic health messages about cancer prevention and screening, including media messages, clinical encounters and clinical print materials. Items were reviewed, revised, and pre-tested. Adults aged 40 to 70 participated in a pilot administration in Georgia, Hawaii, and Massachusetts. Results The Cancer Message Literacy Test-Listening is self-administered via touchscreen laptop computer. No reading is required. It takes approximately 1 hour. The Cancer Message Literacy Test-Reading is self-administered on paper. It takes approximately 10 minutes. Conclusions These two new tests will allow researchers to assess comprehension of spoken health messages, to examine the relationship between listening and reading literacy, and to explore the impact of each form of literacy on health-related outcomes. Practice Implications Researchers and clinicians now have a means of measuring comprehension of spoken health information. PMID:22244323
NASA Astrophysics Data System (ADS)
Fasolt, Bettina; Hodgins, Micah; Seelecke, Stefan
2016-04-01
Screen printing is used as a method for printing electrodes on silicone thin films for the fabrication of dielectric elastomer transducers (DET). This method can be used to manufacture a multitude of patternable designs for actuator and sensor applications, implementing the same method for prototyping as well as large-scale production. The fabrication of DETs does not only require the development of a flexible, highly conductive electrode material, which adheres to a stretched and unstretched silicone film, but also calls for a thorough understanding of the effects of the different printing parameters. This work studies the influence of screen dimensions (open area, mesh thickness) as well as the influence of multiple-layer- printing on the electrode stiffness, electrical resistance and capacitance as well as actuator performance. The investigation was conducted in a custom-built testing device, which enabled an electro-mechanical characterization of the DET, simultaneously measuring parameters such as strain, voltage, current, force, sheet resistance, capacitance and membrane thickness. Magnified pictures of the electrodes will additionally illustrate the effects of the different printing parameters.
Micro-scale NMR Screening of New Detergents for Membrane Protein Structural Biology
Zhang, Qinghai; Horst, Reto; Geralt, Michael; Ma, Xingquan; Hong, Wen-Xu; Finn, M. G.; Stevens, Raymond C.; Wüthrich, Kurt
2008-01-01
The rate limiting step in biophysical characterization of membrane proteins is often the availability of suitable amounts of protein material. It was therefore of interest to demonstrate that micro-coil nuclear magnetic resonance (NMR) technology can be used to screen microscale quantities of membrane proteins for proper folding in samples destined for structural studies. Micoscale NMR was then used to screen a series of newly designed zwitterionic phosphocholine detergents for their ability to reconstitute membrane proteins, using the previously well characterized β-barrel E.coli outer membrane protein OmpX as a test case. Fold screening was thus achieved with μg-amounts of uniformly 2H,15N-labeld OmpX and affordable amounts of the detergents, and prescreening with SDS-gel electrophoresis ensured efficient selection of the targets for NMR studies. A systematic approach to optimize the phosphocholine motif for membrane protein refolding led to the identification of two new detergents, 138-Fos and 179-Fos, that yield 2D [15N,1H]-TROSY correlation NMR spectra of natively folded reconstituted OmpX. PMID:18479092
A Comparison of Atomic Oxygen Degradation in Low Earth Orbit and in a Plasma Etcher
NASA Technical Reports Server (NTRS)
Townsend, Jacqueline A.; Park, Gloria
1997-01-01
In low Earth orbit (LEO) significant degradation of certain materials occurs from exposure to atomic oxygen (AO). Orbital opportunities to study this degradation for specific materials are limited and expensive. While plasma etchers are commonly used in ground-based studies because of their low cost and convenience, the environment produced in an etcher chamber differs greatly from the LEO environment. Because of the differences in environment, the validity of using etcher data has remained an open question. In this paper, degradation data for 22 materials from the orbital experiment Evaluation of Oxygen Interaction with Materials (EOIM-3) are compared with data from EOIM-3 control specimens exposed in a typical plasma etcher. This comparison indicates that, when carefully considered, plasma etcher results can produce order-of-magnitude estimates of orbital degradation. This allows the etcher to be used to screen unacceptable materials from further, more expensive tests.
Early Adoption of a Multitarget Stool DNA Test for Colorectal Cancer Screening.
Finney Rutten, Lila J; Jacobson, Robert M; Wilson, Patrick M; Jacobson, Debra J; Fan, Chun; Kisiel, John B; Sweetser, Seth; Tulledge-Scheitel, Sidna M; St Sauver, Jennifer L
2017-05-01
To characterize early adoption of a novel multitarget stool DNA (MT-sDNA) screening test for colorectal cancer (CRC) screening and to test the hypothesis that adoption differs by demographic characteristics and prior CRC screening behavior and proceeds predictably over time. We used the Rochester Epidemiology Project research infrastructure to assess the use of the MT-sDNA screening test in adults aged 50 to 75 years living in Olmsted County, Minnesota, in 2014 and identified 27,147 individuals eligible or due for screening colonoscopy from November 1, 2014, through November 30, 2015. We used electronic Current Procedure Terminology and Health Care Common Procedure codes to evaluate early adoption of the MT-sDNA screening test in this population and to test whether early adoption varies by age, sex, race, and prior CRC screening behavior. Overall, 2193 (8.1%) and 974 (3.6%) individuals were screened by colonoscopy and MT-sDNA, respectively. Age, sex, race, and prior CRC screening behavior were significantly and independently associated with MT-sDNA screening use compared with colonoscopy use after adjustment for all other variables (P<.05 for all). The rates of adoption of MT-sDNA screening increased over time and were highest in those aged 50 to 54 years, women, whites, and those who had a history of screening. The use of the MT-sDNA screening test varied predictably by insurance coverage. The rates of colonoscopy decreased over time, whereas overall CRC screening rates remained steady. The results of the present study are generally consistent with predictions derived from prior research and the diffusion of innovation framework, pointing to increasing use of the new screening test over time and early adoption by younger patients, women, whites, and those with prior CRC screening. Copyright © 2017 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Phelan-Emrick, Darcy F.; Pollack, Craig E.; Markakis, Diane; Wenzel, Jennifer; Ahmed, Saifuddin; Garza, Mary A.; Shapiro, Gary R.; Bone, Lee R.; Johnson, Lawrence B.; Ford, Jean G.
2015-01-01
Purpose In recent years, colorectal cancer (CRC) screening rates have increased steadily in the USA, though racial and ethnic disparities persist. In a community-based randomized controlled trial, we investigated the effect of patient navigation on increasing CRC screening adherence among older African Americans. Methods Participants in the Cancer Prevention and Treatment Demonstration were randomized to either the control group, receiving only printed educational materials (PEM), or the intervention arm where they were assigned a patient navigator in addition to PEM. Navigators assisted participants with identifying and overcoming screening barriers. Logistic regression analyses were used to assess the effect of patient navigation on CRC screening adherence. Up-to-date with screening was defined as self-reported receipt of colonoscopy/sigmoidoscopy in the previous 10 years or fecal occult blood testing (FOBT) in the year prior to the exit interview. Results Compared with controls, the intervention group was more likely to report being up-to-date with CRC screening at the exit interview (OR 1.55, 95 % CI 1.07–2.23), after adjusting for select demographics. When examining the screening modalities separately, the patient navigator increased screening for colonoscopy/sigmoidoscopy (OR 1.53, 95 % CI 1.07–2.19), but not FOBT screening. Analyses of moderation revealed stronger effects of navigation among participants 65–69 years and those with an adequate health literacy level. Conclusions In a population of older African Americans adults, patient navigation was effective in increasing the likelihood of CRC screening. However, more intensive navigation may be necessary for adults over 70 years and individuals with low literacy levels. PMID:25516073
Horne, Hisani N; Phelan-Emrick, Darcy F; Pollack, Craig E; Markakis, Diane; Wenzel, Jennifer; Ahmed, Saifuddin; Garza, Mary A; Shapiro, Gary R; Bone, Lee R; Johnson, Lawrence B; Ford, Jean G
2015-02-01
In recent years, colorectal cancer (CRC) screening rates have increased steadily in the USA, though racial and ethnic disparities persist. In a community-based randomized controlled trial, we investigated the effect of patient navigation on increasing CRC screening adherence among older African Americans. Participants in the Cancer Prevention and Treatment Demonstration were randomized to either the control group, receiving only printed educational materials (PEM), or the intervention arm where they were assigned a patient navigator in addition to PEM. Navigators assisted participants with identifying and overcoming screening barriers. Logistic regression analyses were used to assess the effect of patient navigation on CRC screening adherence. Up-to-date with screening was defined as self-reported receipt of colonoscopy/sigmoidoscopy in the previous 10 years or fecal occult blood testing (FOBT) in the year prior to the exit interview. Compared with controls, the intervention group was more likely to report being up-to-date with CRC screening at the exit interview (OR 1.55, 95 % CI 1.07-2.23), after adjusting for select demographics. When examining the screening modalities separately, the patient navigator increased screening for colonoscopy/sigmoidoscopy (OR 1.53, 95 % CI 1.07-2.19), but not FOBT screening. Analyses of moderation revealed stronger effects of navigation among participants 65-69 years and those with an adequate health literacy level. In a population of older African Americans adults, patient navigation was effective in increasing the likelihood of CRC screening. However, more intensive navigation may be necessary for adults over 70 years and individuals with low literacy levels.
... including physical and emotional problems. False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...
Miranda, Geraldo Elias; Melani, Rodolfo Francisco Haltenhoff; Francisquini, Luiz; Daruge, Eduardo
2017-01-01
The aim of this study was to identify the combination of wavelength and filter that best detects tooth and bone, and to determine which biological materials (enamel, dental root or bone) have highest fluorescence intensity when exposed to an alternate light source (ALS). Tooth and bone samples were lighted with ALS and photographed. Adobe Photoshop™ and ImageJ™ softwares were used for image analysis. Data obtained by measuring the photograph pixels were subjected to analysis of variance. The mean values of significant effects were compared by the Tukey test. In all tests, the significance level was set at p≤0.05 and the values calculated by the SAS system. The results showed that the best combination for detecting tooth and bone is an illumination wavelength of 455 nm with an orange filter. The fluorescence of dental root is greater than that of enamel, which in turn is greater than that of bone. The biological material had markedly higher fluorescence than the inert material. This knowledge can help the forensic expert to screen and detect biological materials, for example in situations where there are fragmented teeth and small bones, both at the scene and in the laboratory.
Early Adoption of a Multi-target Stool DNA Test for Colorectal Cancer Screening
Finney Rutten, Lila J.; Jacobson, Robert M.; Wilson, Patrick M.; Jacobson, Debra J.; Fan, Chun; Kisiel, John B.; Sweetser, Seth R.; Tulledge-Scheitel, Sidna M.; St. Sauver, Jennifer L.
2017-01-01
Objective To characterize early adoption of a novelmulti-target stool deoxyribonucleic acid (MTsDNA) screening test for colorectal cancer (CRC) and test the hypothesis that adoption differs by demographic characteristics, prior CRC screening behavior, and proceeds predictably over time. Patients and Methods We used the Rochester Epidemiology Project infrastructure to assess MTsDNA screening test use among adults aged 50–75 years, and identified 27,147 individuals eligible/due for screening colonoscopy from November 1, 2014 through November 30, 2015, and living in Olmsted County, Minnesota in2014. We used electronic Current Procedure Terminology and Health Care Common Procedure codes to evaluate early adoption of MTsDNA screening test in this population and to test whether early adoption varies by age, sex, race, and prior screening behavior. Results Overall, 2,193 (8.1%) and 974 (3.6%) of individuals were screened by colonoscopy and MT-sDNA, respectively. Age, sex, race, and prior screening were significantly and independently associated with MT-sDNA screening use compared to colonoscopy use after adjustment for all other variables. Rates of adoption of MTsDNA screening increased over time and were highest among those aged 50–54 years, females, whites, and had a prior history of screening. MT-sDNA screening use varied predictably by insurance coverage. Rates of colonoscopy decreased over time, while overall CRC screening rates remained steady. Conclusion Our results are generally consistent with predictions derived from prior research and Diffusion of Innovation framework, pointing to increasing use of the new screening test over time, and early adoption by younger patients, females, whites and those with prior CRC screening. PMID:28473037
Becker, Elizabeth A.; Griffith, Derek M.; West, Brady T.; Janz, Nancy K.; Resnicow, Ken; Morris, Arden M.
2015-01-01
Background Screening and post-symptomatic diagnostic testing are often conflated in cancer screening surveillance research. We examined the error in estimated colorectal cancer (CRC) screening prevalence due to the conflation of screening and diagnostic testing. Methods Using data from the 2008 National Health Interview Survey, we compared weighted prevalence estimates of the use of all testing (screening and diagnostic) and screening in at-risk adults, and calculated the overestimation of screening prevalence across socio-demographic groups. Results The population screening prevalence was overestimated by 23.3%, and the level of overestimation varied widely across socio-demographic groups (median 22.6%, mean 24.8%). The highest levels of overestimation were in non-Hispanic White females (27.4%), adults ages 50–54 (32.0%), and those with the highest socioeconomic vulnerability (low educational attainment (31.3%), low poverty ratio (32.5%), no usual source of health care (54.4%) and not insured (51.6%)) (all p-values < 0.001). Conclusions When the impetus for testing was not included, CRC screening prevalence was overestimated, and patterns of overestimation often aligned with social and economic vulnerability. These results are of concern to researchers who utilize survey data from the Behavioral Risk Factor Surveillance System (BRFSS) to assess cancer screening behaviors, as it is currently not designed to distinguish diagnostic testing from screening. Impact Surveillance research in cancer screening that does not consider the impetus for testing risks measurement error of screening prevalence, impeding progress toward improving population health. Ultimately, in order to craft relevant screening benchmarks and interventions, we must look beyond ‘what’ and ‘when’ and include ‘why.’ PMID:26491056
Rudresh, Shoorashetty Manohara; Ravi, Giriyapur Siddappa; Sunitha, Lakshminarayanappa; Hajira, Sadiya Noor; Kalaiarasan, Ellappan; Harish, Belgode Narasimha
2017-01-01
PURPOSE: Detection of carbapenemases among Gram-negative bacteria (GNB) is important for both clinicians and infection control practitioners. The Clinical and Laboratory Standards Institute recommends Carba NP (CNP) as confirmatory test for carbapenemase production. The reagents required for CNP test are costly and hence the test cannot be performed on a routine basis. The present study evaluates modifications of CNP test for rapid detection of carbapenemases among GNB. MATERIALS AND METHODS: The GNB were screened for carbapenemase production using CNP, CarbAcineto NP (CANP), and modified CNP (mCNP) test. A multiplex polymerase chain reaction (PCR) was performed on all the carbapenem-resistant bacteria for carbapenemase genes. The results of three phenotypic tests were compared with PCR. RESULTS: A total of 765 gram negative bacteria were screened for carbapenem resistance. Carbapenem resistance was found in 144 GNB. The metallo-β-lactamases were most common carbapenemases followed by OXA-48-like enzymes. The CANP test was most sensitive (80.6%) for carbapenemases detection. The mCNP test was 62.1% sensitive for detection of carbapenemases. The mCNP, CNP, and CANP tests were equally sensitive (95%) for detection of NDM enzymes among Enterobacteriaceae. The mCNP test had poor sensitivity for detection of OXA-48-like enzymes. CONCLUSION: The mCNP test was rapid, cost-effective, and easily adoptable on routine basis. The early detection of carbapenemases using mCNP test will help in preventing the spread of multidrug-resistant organisms in the hospital settings. PMID:28966495
Treatability by Cryotherapy in a Screen-and-Treat Strategy
Gage, JC; Rodriguez, AC; Schiffman, M; Garcia, FA; Long, LR; Budihas, S; Herrero, R; Burk, RD; Jeronimo, J
2009-01-01
Objectives We estimated the percentage of women infected with human papillomavirus (HPV+) who cannot be immediately treated with cryotherapy. Materials and Methods In a 10,000-woman Costa Rican cohort, we analyzed the 559 HPV+ women aged 25-55, and estimated the proportion for whom immediate cryotherapy was not indicated (i.e., invasive cancer, large precancerous lesions, or benign abnormalities that risk failure such as large ectopy, squamocolumnar junction not visualized, polyps, ulcers, or distorted or atrophied cervix). To determine whether cryotherapy at time of baseline HPV screening would effectively treat HPV+ women, two expert gynecologists independently judged entire clinical histories (5-7 years of cytology, histology, and HPV tests) and a full longitudinal series of digitized cervical images.. Results Reviewers judged 144 (25.8%) of 559 HPV+ women as not treatable by immediate cryotherapy. Among 72 women with cervical intraepithelial neoplasia grade 3 (CIN3) who would benefit most from a screening program, 35 (48.6%) were not treatable. In particular, 29 women (40.3%) were determined not treatable for reasons most likely associated with cryotherapy's inadequacy (lesion was large, suspected cancerous or in the endocervical canal or fornix). Conclusions “Screen-and-treat” programs in low-resource settings will soon use a rapid HPV test to screen older women once or twice in their lifetime, identifying women at higher risk for precancer. Our findings suggest cryotherapy might not effectively treat many precancers and other safe, low-technology treatment options could be required, in a scenario where all HPV+ women in this targeted group would receive cryotherapy at the same visit. PMID:19550216
... may have serious side effects . False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...
Glucose screening tests during pregnancy
Oral glucose tolerance test - pregnancy; OGTT - pregnancy; Glucose challenge test - pregnancy; Gestational diabetes - glucose screening ... first step, you will have a glucose screening test: You DO NOT need to prepare or change ...
Roebuck-Spencer, Tresa M; Glen, Tannahill; Puente, Antonio E; Denney, Robert L; Ruff, Ronald M; Hostetter, Gayle; Bianchini, Kevin J
2017-06-01
The American Medical Association Current Procedural Panel developed a new billing code making behavioral health screening a reimbursable healthcare service. The use of computerized testing as a means for cognitive screening and brief cognitive testing is increasing at a rapid rate. The purpose of this education paper is to provide information to clinicians, healthcare administrators, and policy developers about the purpose, strengths, and limitations of cognitive screening tests versus comprehensive neuropsychological evaluations. Screening tests are generally brief and narrow in scope, they can be administered during a routine clinical visit, and they can be helpful for identifying individuals in need of more comprehensive assessment. Some screening tests can also be helpful for monitoring treatment outcomes. Comprehensive neuropsychological assessments are multidimensional in nature and used for purposes such as identifying primary and secondary diagnoses, determining the nature and severity of a person's cognitive difficulties, determining functional limitations, and planning treatment and rehabilitation. Cognitive screening tests are expected to play an increasingly important role in identifying individuals with cognitive impairment and in determining which individuals should be referred for further neuropsychological assessment. However, limitations of existing cognitive screening tests are present and cognitive screening tests should not be used as a replacement for comprehensive neuropsychological testing. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Screening tests for aphasia in patients with stroke: a systematic review.
El Hachioui, Hanane; Visch-Brink, Evy G; de Lau, Lonneke M L; van de Sandt-Koenderman, Mieke W M E; Nouwens, Femke; Koudstaal, Peter J; Dippel, Diederik W J
2017-02-01
Aphasia has a large impact on the quality of life and adds significantly to the costs of stroke care. Early recognition of aphasia in stroke patients is important for prognostication and well-timed treatment planning. We aimed to identify available screening tests for differentiating between aphasic and non-aphasic stroke patients, and to evaluate test accuracy, reliability, and feasibility. We searched PubMed, EMbase, Web of Science, and PsycINFO for published studies on screening tests aimed at assessing aphasia in stroke patients. The reference lists of the selected articles were scanned, and several experts were contacted to detect additional references. Of each screening test, we estimated the sensitivity, specificity, likelihood ratio of a positive test, likelihood ratio of a negative test, and diagnostic odds ratio (DOR), and rated the degree of bias of the validation method. We included ten studies evaluating eight screening tests. There was a large variation across studies regarding sample size, patient characteristics, and reference tests used for validation. Many papers failed to report on the consecutiveness of patient inclusion, time between aphasia onset and administration of the screening test, and blinding. Of the three studies that were rated as having an intermediate or low risk of bias, the DOR was highest for the Language Screening Test and ScreeLing. Several screening tools for aphasia in stroke are available, but many tests have not been verified properly. Methodologically sound validation studies of aphasia screening tests are needed to determine their usefulness in clinical practice.
42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...
42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 2 2011-10-01 2011-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...
42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 2 2013-10-01 2013-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...
42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 2 2012-10-01 2012-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...
42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 2 2014-10-01 2014-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...
Pap Testing Stages of Adoption among Cambodian Immigrants
Taylor, Victoria M.; Jackson, J. Carey; Yasui, Yutaka; Schwartz, Stephen M.; Kuniyuki, Alan; Fischer, Meredith; Tu, Shin-Ping
2006-01-01
Purpose We examined levels of Pap testing and factors associated with screening participation among Cambodian refugees. Methods A community-based, in-person survey was conducted in Seattle during late 1997 and early 1998. Interviews were completed by 413 women; the estimated response rate was 73%. We classified respondents into four Pap testing stages of adoption: precontemplation/contemplation (never screened), relapse (ever screened but did not plan to be screened in the future), action (ever screened and planned to be screened in the future), and maintenance (recently screened and planned to be screened in the future). Bivariate and multivariate techniques were used to examine various factors. Findings About one-quarter (24%) of the respondents has never been screened, and a further 22% had been screened but did not plan to obtain Pap tests in the future. Fifteen percent were in the action stage and 39% were in the maintenance stage. The following factors were independently associated with cervical cancer screening stages: previous physician recommendation; younger age; beliefs about Pap testing for post-menopausal women, screening for sexually inactive women, and regular checkups; provider ethnicity; prenatal care in the US; and problems finding interpreters. Conclusions Our findings confirm low Pap testing rates among Cambodian immigrants, and suggest that targeted interventions should be multifaceted. PMID:11567513
40 CFR 799.9355 - TSCA reproduction/developmental toxicity screening test.
Code of Federal Regulations, 2011 CFR
2011-07-01
... toxicity screening test. 799.9355 Section 799.9355 Protection of Environment ENVIRONMENTAL PROTECTION... AND MIXTURE TESTING REQUIREMENTS Health Effects Test Guidelines § 799.9355 TSCA reproduction/developmental toxicity screening test. (a) Scope—(1) Applicability. This section is intended to meet testing...
40 CFR 799.9355 - TSCA reproduction/developmental toxicity screening test.
Code of Federal Regulations, 2014 CFR
2014-07-01
... toxicity screening test. 799.9355 Section 799.9355 Protection of Environment ENVIRONMENTAL PROTECTION... AND MIXTURE TESTING REQUIREMENTS Health Effects Test Guidelines § 799.9355 TSCA reproduction/developmental toxicity screening test. (a) Scope—(1) Applicability. This section is intended to meet testing...
The National Lung Screening Trial: Overview and Study Design1
2011-01-01
The National Lung Screening Trial (NLST) is a randomized multicenter study comparing low-dose helical computed tomography (CT) with chest radiography in the screening of older current and former heavy smokers for early detection of lung cancer, which is the leading cause of cancer-related death in the United States. Five-year survival rates approach 70% with surgical resection of stage IA disease; however, more than 75% of individuals have incurable locally advanced or metastatic disease, the latter having a 5-year survival of less than 5%. It is plausible that treatment should be more effective and the likelihood of death decreased if asymptomatic lung cancer is detected through screening early enough in its preclinical phase. For these reasons, there is intense interest and intuitive appeal in lung cancer screening with low-dose CT. The use of survival as the determinant of screening effectiveness is, however, confounded by the well-described biases of lead time, length, and overdiagnosis. Despite previous attempts, no test has been shown to reduce lung cancer mortality, an endpoint that circumvents screening biases and provides a definitive measure of benefit when assessed in a randomized controlled trial that enables comparison of mortality rates between screened individuals and a control group that does not undergo the screening intervention of interest. The NLST is such a trial. The rationale for and design of the NLST are presented. © RSNA, 2010 Clinical trial registration no. NCT 00047385 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.10091808/-/DC1 PMID:21045183
Wakewich, Pamela; Wood, Brianne; Davey, Crystal; Laframboise, Ashlie; Zehbe, Ingeborg
2016-01-01
Regular Papanicolaou (Pap) screening has dramatically reduced cervical cancer incidence in Canada since the 1950s. However, Indigenous women’s rates of cervical cancer remain disproportionately high, a factor which is not acknowledged in national media or in educational materials reporting Canada’s new cervical cancer screening guidelines. Here, we present findings from a cervical cancer screening initiative in Northwestern Ontario. Based on participatory action research, we worked with 10 First Nations communities in the Robinson Superior Treaty area to increase awareness of cervical cancer risk, develop culturally sensitive tools for screening and education and test the efficacy of human papillomavirus (HPV) self-sampling as an alternative to Pap cytology. We conducted 16 interviews with health care professionals and 9 focus groups with 69 women from the communities. A central theme for both health care providers (HCPs) and community members was the colonial legacy and its influence on women’s experiences of cervical cancer screening. This was evidenced by a strong sense of body shyness, including shame related to sexuality and sexually transmitted infections, concerns about confidentiality in clinical encounters and distrust or caution around HCPs. Reaffirming women’s traditional caregiving and educational roles, enhancing mother and daughter communication, improving cultural sensitivity in health care and education and adoption of HPV self-sampling to increase women’s privacy and control of the cervical cancer screening experience were endorsed. We argue that education and screening initiatives must reflect the cultural preferences of Indigenous women, empowering them to take control of their experiences of health and body in cervical cancer screening. PMID:27867262
Practical aspects of mutagenicity testing strategy: an industrial perspective.
Gollapudi, B B; Krishna, G
2000-11-20
Genetic toxicology studies play a central role in the development and marketing of new chemicals for pharmaceutical, agricultural, industrial, and consumer use. During the discovery phase of product development, rapid screening tests that require minimal amounts of test materials are used to assist in the design and prioritization of new molecules. At this stage, a modified Salmonella reverse mutation assay and an in vitro micronucleus test with mammalian cell culture are frequently used for screening. Regulatory genetic toxicology studies are conducted with a short list of compounds using protocols that conform to various international guidelines. A set of four assays usually constitutes the minimum test battery that satisfies global requirements. This set includes a bacterial reverse mutation assay, an in vitro cytogenetic test with mammalian cell culture, an in vitro gene mutation assay in mammalian cell cultures, and an in vivo rodent bone marrow micronucleus test. Supplementary studies are conducted in certain instances either as a follow-up to the findings from this initial testing battery and/or to satisfy a regulatory requirement. Currently available genetic toxicology assays have helped the scientific and industrial community over the past several decades in evaluating the mutagenic potential of chemical agents. The emerging field of toxicogenomics has the potential to redefine our ability to study the response of cells to genetic damage and hence our ability to study threshold phenomenon.
HPV primary cervical screening in England: Women's awareness and attitudes.
Patel, Hersha; Moss, Esther L; Sherman, Susan M
2018-03-09
Primary human papillomavirus (HPV) cervical screening is due to be implemented in England within the next 2 years; however, the acceptability of HPV testing as the primary screening test is unclear. This study explores women's awareness and attitudes toward HPV testing/screening. Qualitative interviews (semistructured and focus group) were conducted with 46 women (aged 25-65 years) from community and secondary care settings. Data were analyzed by using the inductive-framework method. Women were unaware that cervical screening currently includes HPV testing and lacked HPV-related knowledge. Emotions of shock, fear, and anxiety were reported upon receiving a positive HPV result. For women in long-term relationships, the realization that HPV is a sexually transmitted infection was seen as a barrier to primary HPV testing. Knowledge that HPV testing is a screening test to prevent cervical cancer did not change their attitudes. Women debated the need for continued screening following a negative result. Women feared judgment by the community if they participated with primary HPV screening because they were being tested for a sexually transmitted infection, with the possible attendant perception that they had adopted a high-risk lifestyle in comparison to nonattenders. The acceptability of HPV testing may be a limiting factor in encouraging participation with screening in the future. Copyright © 2018 John Wiley & Sons, Ltd.
Metallic biomaterials TiN-coated: corrosion analysis and biocompatibility.
Paschoal, André Luís; Vanâncio, Everaldo Carlos; Canale, Lauralice de Campos Franceschini; da Silva, Orivaldo Lopes; Huerta-Vilca, Domingos; Motheo, Artur de Jesus
2003-05-01
Corrosion processes due to contact with the physiological environment should be avoided or minimized in orthopedic implants. Four metallic substrates frequently used as biomaterials: pure Ti, Ti-6Al-4V alloy, ASTM F138 stainless steel, and Co-Cr-Mo alloy, were coated with TiN using the physical vapor deposition (PVD) technique. These coatings have been screened by polarization curves in physiological solutions. TiN prepared by PVD is efficient as coating for stainless steel. On titanium and alloy there are no benefits concerning the corrosion resistance compared to the bare Ti-materials. TiN coatings have been screened according to ISO 10993 standard tests for biocompatibility and exhibited no cytotoxicity, dermal irritation, or acute systemic toxicity response.
[Evaluation of peruvian money test in screening of cognitive impairment among older adults].
Oscanoa, Teodoro J; Cieza, Edwin; Parodi, José F; Paredes, Napoleón
2016-03-01
Objectives To evaluate the Peruvian adaptation of the money test (Eurotest) for identifying cognitive impairment among >60-year-old adults. Materials and methods This is a phase I study of diagnostic test, with a convenience sampling and calculation of the test´s sensitivity and specificity, based on a pretest prevalence of 50%. The criteria of the Diagnostic and Statistical Manual of Mental Disorders (DSM IV) and Global Deterioration Scale (GDS) were used for the operational definition of patients with cognitive impairment. Receiver operating characteristic (ROC) curve analysis was used to identify the optimal cut-off value. Results The study evaluated 42 cases and 42 controls; there was no significant difference between age (77.88 ± 6.01 years vs. 6.49 76.14 ± years) and years of education (13.69 ± 3.70 years vs. 8.17 ± 4.71 years). The Peruvian version of the Eurotest has a sensitivity of 90.5% and specificity of 83.3% with cut-off value of 24. Conclusions The Peruvian adapted version of the Eurotest, called prueba de la moneda peruana could be useful in screening for cognitive impairment among older adults.
Risks of Skin Cancer Screening
... may have serious side effects . False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...
21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening test for HBsAg); and (4) Hepatitis C (e.g., FDA licensed screening test for anti-HCV). (b) In the case... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...
Discrete Element Modeling (DEM) of Triboelectrically Charged Particles: Revised Experiments
NASA Technical Reports Server (NTRS)
Hogue, Michael D.; Calle, Carlos I.; Curry, D. R.; Weitzman, P. S.
2008-01-01
In a previous work, the addition of basic screened Coulombic electrostatic forces to an existing commercial discrete element modeling (DEM) software was reported. Triboelectric experiments were performed to charge glass spheres rolling on inclined planes of various materials. Charge generation constants and the Q/m ratios for the test materials were calculated from the experimental data and compared to the simulation output of the DEM software. In this paper, we will discuss new values of the charge generation constants calculated from improved experimental procedures and data. Also, planned work to include dielectrophoretic, Van der Waals forces, and advanced mechanical forces into the software will be discussed.
Development of Low Density, Flexible Carbon Phenolic Ablators
NASA Technical Reports Server (NTRS)
Stackpoole, Mairead; Thornton, Jeremy; Fan, Wendy; Covington, Alan; Doxtad, Evan; Beck, Robin; Gasch, Matt; Arnold, Jim
2012-01-01
Phenolic Impregnated Carbon Ablator (PICA) was the enabling TPS material for the Stardust mission where it was used as a single piece heatshield. PICA has the advantages of low density (approximately 0.27 grams per cubic centimeter) coupled with efficient ablative capability at high heat fluxes. Due to its brittle nature and low strain to failure recent efforts at NASA ARC have focused on alternative architectures to yield flexible and more conformal carbon phenolic materials with comparable densities to PICA. This presentation will discuss flexible alternatives to PICA and include preliminary mechanical and thermal properties as well as recent arc jet and LHMEL screening test results.
Process evaluation of health fairs promoting cancer screenings.
Escoffery, Cam; Liang, Shuting; Rodgers, Kirsten; Haardoerfer, Regine; Hennessy, Grace; Gilbertson, Kendra; Heredia, Natalia I; Gatus, Leticia A; Fernandez, Maria E
2017-12-18
Low income and uninsured individuals often have lower adherence to cancer screening for breast, cervical and colorectal cancer. Health fairs are a common community outreach strategy used to provide cancer-related health education and services. This study was a process evaluation of seven health fairs focused on cancer screening across the U.S. We conducted key-informant interviews with the fair coordinator and conducted baseline and follow-up surveys with fair participants to describe characteristics of participants as well as their experiences. We collected baseline data with participants at the health fairs and telephone follow-up surveys 6 months following the fair. Attendance across the seven health fairs ranged from 41 to 212 participants. Most fairs provided group or individual education, print materials and cancer screening during the event. Overall, participants rated health fairs as very good and participants reported that the staff was knowledgeable and that they liked the materials distributed. After the fairs, about 60% of participants, who were reached at follow-up, had read the materials provided and had conversations with others about cancer screening, and 41% talked to their doctors about screening. Based on findings from evaluation including participant data and coordinator interviews, we describe 6 areas in planning for health fairs that may increase their effectiveness. These include: 1) use of a theoretical framework for health promotion to guide educational content and activities provided, 2) considering the community characteristics, 3) choosing a relevant setting, 4) promotion of the event, 5) considerations of the types of services to deliver, and 6) evaluation of the health fair. The events reported varied in reach and the participants represented diverse races and lower income populations overall. Most health fairs offered education, print materials and onsite cancer screening. Participants reported general satisfaction with these events and were motivated through their participation to read educational materials or discuss screening with providers. Public health professionals can benefit from this process evaluation and recommendations for designing and evaluating health fairs.
Isolation and enrichment of circulating biomarkers for cancer screening, detection, and diagnostics.
Hyun, Kyung-A; Kim, Junmoo; Gwak, Hogyeong; Jung, Hyo-Il
2016-01-21
Much research has been performed over the past several decades in an attempt to conquer cancer. Tissue biopsy is the conventional method for gathering biological materials to analyze cancer and has contributed greatly to the understanding of cancer. However, this method is limited because it is time-consuming (requires tissue sectioning, staining, and pathological analysis), costly, provides scarce starting materials for multiple tests, and is painful. A liquid biopsy, which analyzes cancer-derived materials from various body fluids using a minimally invasive procedure, is more practical for real-time monitoring of disease progression than tissue biopsy. Biomarkers analyzable through liquid biopsy include circulating tumor cells (CTCs), exosomes, circulating cell-free DNA (cfDNA), miRNA, and proteins. Research on CTCs has been actively conducted because CTCs provide information on the whole cell, unlike the other biomarkers mentioned above. However, owing to the rarity and heterogeneity of CTCs, CTC research faces many critical concerns. Although exosomes and cfDNA have some technical challenges, they are being highlighted as new target materials. That is because they also have genetic information on cancers. Even though the number of exosomes and cfDNA from early stage cancer patients are similar to healthy individuals, they are present in high concentrations after metastasis. In this article, we review several technologies for material analyses of cancer, discuss the critical concerns based on hands-on experience, and describe future directions for cancer screening, detection, and diagnostics.
Buttner, Mark P.; Cruz, Patricia; Stetzenbach, Linda D.; Cronin, Tracy
2007-01-01
This research was designed to evaluate surface sampling protocols for use with culture and quantitative PCR (QPCR) amplification assay for detection of the gram-negative bacterial biothreat simulant Erwinia herbicola on a variety of surface materials. Surfaces selected for evaluation were wood laminate, glass and computer monitor screens, metal file cabinets, plastic arena seats, nylon seat cushions, finished concrete flooring, and vinyl tile flooring. Laboratory and test chamber studies were performed to evaluate two sampling methods, a sponge and a macrofoam swab, for detection of E. herbicola on surface materials. In laboratory trials, seven materials were inoculated with a known concentration of E. herbicola cells and samples were collected from the surfaces of the materials to determine sampling efficiencies. Culture analysis was ineffective for assessing E. herbicola collection efficiency because very few culturable cells were obtained from surface samples. QPCR demonstrated that E. herbicola DNA was present in high concentrations on all of the surface samples, and sampling efficiencies ranged from 0.7 to 52.2%, depending on the sampling method and the surface material. The swab was generally more efficient than the sponge for collection of E. herbicola from surfaces. Test chamber trials were also performed in which E. herbicola was aerosolized into the chamber and allowed to settle onto test materials. Surface sampling results supported those obtained in laboratory trials. The results of this study demonstrate the capabilities of QPCR to enhance the detection and enumeration of biocontaminants on surface materials and provide information on the comparability of sampling methods. PMID:17416685
Buttner, Mark P; Cruz, Patricia; Stetzenbach, Linda D; Cronin, Tracy
2007-06-01
This research was designed to evaluate surface sampling protocols for use with culture and quantitative PCR (QPCR) amplification assay for detection of the gram-negative bacterial biothreat simulant Erwinia herbicola on a variety of surface materials. Surfaces selected for evaluation were wood laminate, glass and computer monitor screens, metal file cabinets, plastic arena seats, nylon seat cushions, finished concrete flooring, and vinyl tile flooring. Laboratory and test chamber studies were performed to evaluate two sampling methods, a sponge and a macrofoam swab, for detection of E. herbicola on surface materials. In laboratory trials, seven materials were inoculated with a known concentration of E. herbicola cells and samples were collected from the surfaces of the materials to determine sampling efficiencies. Culture analysis was ineffective for assessing E. herbicola collection efficiency because very few culturable cells were obtained from surface samples. QPCR demonstrated that E. herbicola DNA was present in high concentrations on all of the surface samples, and sampling efficiencies ranged from 0.7 to 52.2%, depending on the sampling method and the surface material. The swab was generally more efficient than the sponge for collection of E. herbicola from surfaces. Test chamber trials were also performed in which E. herbicola was aerosolized into the chamber and allowed to settle onto test materials. Surface sampling results supported those obtained in laboratory trials. The results of this study demonstrate the capabilities of QPCR to enhance the detection and enumeration of biocontaminants on surface materials and provide information on the comparability of sampling methods.
Halpern, Michael T; Romaire, Melissa A; Haber, Susan G; Tangka, Florence K; Sabatino, Susan A; Howard, David H
2014-10-01
Although state Medicaid programs cover cancer screening, Medicaid beneficiaries are less likely to be screened for cancer and are more likely to present with tumors of an advanced stage than are those with other insurance. The current study was performed to determine whether state Medicaid eligibility and reimbursement policies affect the receipt of breast, cervical, and colon cancer screening among Medicaid beneficiaries. Cross-sectional regression analyses of 2007 Medicaid data from 46 states and the District of Columbia were performed to examine associations between state-specific Medicaid reimbursement/eligibility policies and receipt of cancer screening. The study sample included individuals aged 21 years to 64 years who were enrolled in fee-for-service Medicaid for at least 4 months. Subsamples eligible for each screening test were: Papanicolaou test among 2,136,511 patients, mammography among 792,470 patients, colonoscopy among 769,729 patients, and fecal occult blood test among 753,868 patients. State-specific Medicaid variables included median screening test reimbursement, income/financial asset eligibility requirements, physician copayments, and frequency of eligibility renewal. Increases in screening test reimbursement demonstrated mixed associations (positive and negative) with the likelihood of receiving screening tests among Medicaid beneficiaries. In contrast, increased reimbursements for office visits were found to be positively associated with the odds of receiving all screening tests examined, including colonoscopy (odds ratio [OR], 1.07; 95% confidence interval [95% CI], 1.06-1.08), fecal occult blood test (OR, 1.09; 95% CI, 1.08-1.10), Papanicolaou test (OR, 1.02; 95% CI, 1.02-1.03), and mammography (OR, 1.02; 95% CI, 1.02-1.03). Effects of other state-specific Medicaid policies varied across the screening tests examined. Increased reimbursement for office visits was consistently associated with an increased likelihood of being screened for cancer, and may be an important policy tool for increasing screening among this vulnerable population. © 2014 American Cancer Society.
Cantor, Amy G; Pappas, Miranda; Daeges, Monica; Nelson, Heidi D
2016-06-07
Screening for syphilis infection is currently recommended for high-risk individuals, including those with previous syphilis infection, an infected sexual partner, HIV infection, or more than 4 sex partners in the preceding year. To update a 2004 systematic review of studies of syphilis screening effectiveness, test accuracy, and screening harms in nonpregnant adults and adolescents. Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews through October 2015 and Ovid MEDLINE (January 2004 to October 2015), with updated search through March 2016. English-language trials and observational studies of screening effectiveness, test accuracy, and screening harms in nonpregnant adults and adolescents. One investigator abstracted data, a second checked data for accuracy, and 2 investigators independently assessed study quality using predefined criteria. Transmission of disease, including HIV; complications of syphilis; diagnostic accuracy; and harms of screening. No evidence was identified regarding the effectiveness of screening on clinical outcomes or the effectiveness of risk assessment instruments; the harms of screening; or the effectiveness of screening in average-risk, nonpregnant adolescents or adults or high-risk individuals other than men who have sex with men (MSM) or men who are HIV positive. Four non-US studies indicated higher rates of syphilis detection with screening every 3 months vs 6 or 12 months for early syphilis in HIV-positive men or MSM. For example, there was an increased proportion of asymptomatic, higher-risk MSM in Australia (n = 6789 consultations) receiving a diagnosis of early syphilis when tested every 3 months vs annually (53% vs 16%, P = .001), but no difference among low-risk MSM. Treponemal and nontreponemal tests were accurate in asymptomatic individuals (sensitivity >85%, specificity >91%) in 3 studies but required confirmatory testing. Reverse sequence testing with an initial automated treponemal test yielded more false reactive test results than with rapid plasma reagin in 2 studies, one with a low-prevalence US population (0.6% vs 0.0%, P = .03) and another in a higher-prevalence Canadian population (0.26% vs 0.13%). Screening HIV-positive men or MSM for syphilis every 3 months is associated with improved syphilis detection. Treponemal or nontreponemal tests are accurate screening tests but require confirmation. Research is needed on the effect of screening on clinical outcomes; effective screening strategies, including reverse sequence screening, in various patient populations; and harms of screening.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eperin, A.P.; Zakharzhevsky, Yu.O.; Arzhaev, A.I.
A two-year Finnish-Russian cooperation program has been initiated in 1995 to demonstrate the applicability of the leak-before-break concept (LBB) to the primary circuit piping of the Leningrad NPP. The program includes J-R curve testing of authentic pipe materials at full operating temperature, screening and computational LBB analyses complying with the USNRC Standard Review Plan 3.6.3, and exchange of LBB-related information with emphasis on NDE. Domestic computer codes are mainly used, and all tests and analyses are independently carried out by each party. The results are believed to apply generally to RBMK type plants of the first generation.
NASA Technical Reports Server (NTRS)
Alter, W. S.; Parr, R. A.; Johnston, M. H.; Strizak, J. P.
1984-01-01
A screening program to determine the effects of high pressure hydrogen on selected candidate materials for advanced single crystal turbine blade applications is examined. The alloys chosen for the investigation are CM SX-2, CM SX-4C, Rene N-4, and PWA1480. Testing is carried out in hydrogen and helium at 34 MPa and room temperature, with both notched and unnotched single crystal specimens. Results show a significant variation in susceptibility to Hydrogen Environment Embrittlement (HEE) among the four alloys and a marked difference in fracture topography between hydrogen and helium environment specimens.
Screening for coronary heart disease risk factors in retail pharmacies in Sheffield, 1992.
Allison, C; Page, H; George, S
1994-01-01
OBJECTIVE--To investigate the current and likely future provision of screening services for risk factors for coronary heart disease in retail pharmacies in Sheffield. DESIGN--This was a questionnaire survey asking about screening tests currently offered, price charged per test, likely future provision of screening tests, the action respondents would take upon finding an abnormal test result, whether the pharmacy was owner-run, franchised, or part of a commercial chain, and inviting open comments from respondents. SETTING--All retail pharmacy premises on the Sheffield Family Health Services Authority list. RESULTS--Seventy seven responses were obtained to 102 questionnaires distributed. Only nine of these currently offered any screening test other than pregnancy testing, although 37 indicated that they might offer tests in the future. Thirty nine were not offering screening and had no plans to do so. Pharmacies offering or likely to offer screening tests were mainly owner-run. All pharmacists who replied to the question asking about their action upon finding abnormal result (33) reported that they would advise the patient to see a doctor. The most frequent comments made by pharmacists were about the commercial viability of screening in pharmacies and the lack of space available to ensure patient privacy and confidentiality during screening. CONCLUSIONS--Screening in retail pharmacies would probably be a commercial failure unless doctors were able to contract for screening services from pharmacies. Evidence from this study and others, however, leads us to question the desirability of this option. PMID:8189175
Hydroxychloroquine screening practice patterns within a large multispecialty ophthalmic practice.
Au, Adrian; Parikh, Vishal; Modi, Yasha S; Ehlers, Justis P; Schachat, Andrew P; Singh, Rishi P
2015-09-01
To determine provider compliance with hydroxychloroquine screening following the revised recommendations published in 2011 by the American Academy of Ophthalmology. Evaluation of adherence to a screening protocol. Subjects were identified with hydroxychloroquine as a medication by electronic query at a large multispecialty ophthalmic practice. Patients were excluded if patients: (1) were screened by an outside physician; (2) lacked recorded height, weight, start date, or dosing; or (3) took hydroxychloroquine for malaria prophylaxis. Screening tests were stratified by ophthalmic subspecialty. Guidelines define proper screening as 1 subjective test-Humphrey visual field (HVF), and 1 objective test-spectral-domain optical coherence tomography (SD OCT), fundus autofluorescence (FAF), or multifocal electroretinography (mfERG). Adherence to guidelines was determined by categorizing practices as: (1) "appropriate"-consistent with guidelines; (2) "underscreened"-insufficient testing; or (3) "inappropriate"-no testing. The study comprised 756 patients with a mean age of 56 years undergoing 1294 screening visits. Twenty-one patients received initial screenings outside the institution. Most common screening tests employed included SD OCT (56.6%), 10-2 HVF (55.0%), and Amsler grid (40.0%). Of the 735 initial screenings, 341 (46.4%) were appropriately screened, 204 (27.8%) underscreened, and 190 (25.9%) inappropriately screened. Of those who presented solely for screening (560), 307 (54.8%) were appropriately screened, 144 (25.7%) underscreened, and 109 (19.5%) inappropriately screened. Of patients presenting for hydroxychloroquine screening, 54.8% of patients received appropriate evaluation, indicating lack of adherence to guidelines. Overall, SD OCT and 10-2 HVF were the preferred screening modalities, with FAF and mfERG less frequently ordered. Copyright © 2015 Elsevier Inc. All rights reserved.
42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Newborn screening test system for amino acids... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a) Identification. A newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Newborn screening test system for amino acids... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a) Identification. A newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...
42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 2 2011-10-01 2011-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...
42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 2 2012-10-01 2012-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...
42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 2 2013-10-01 2013-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...
42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 2 2014-10-01 2014-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...
The relative importance of patient-reported barriers to colorectal cancer screening.
Jones, Resa M; Woolf, Steven H; Cunningham, Tina D; Johnson, Robert E; Krist, Alex H; Rothemich, Stephen F; Vernon, Sally W
2010-05-01
Colorectal cancer (CRC) screening rates are suboptimal. The most important barriers identified by patients are poorly understood. A comprehensive assessment of barriers to all recommended modalities is needed. In 2007, a questionnaire was mailed to 6100 patients, aged 50-75 years, from 12 family medicine practices in the Virginia Ambulatory Care Outcomes Research Network. People aged 65-75 years and African Americans were oversampled. Patients were asked to rate 19-21 barriers to each of four recommended tests. In 2008, responses were coded on a 5-point scale; higher scores reflected stronger barrier endorsement. The response rate was 55% (n=3357). Approximately 40% of respondents were aged >/=65 years, 30% were African-American, and 73% were adherent to screening. A clinician's failure to suggest screening and not knowing testing was necessary received the highest mean scores as barriers. Financial concerns and misconceptions were also cited. Barrier scores differed depending on whether respondents were never screened, overdue for screening, or adherent to guidelines. The top five barriers for each modality included test-specific barriers (e.g., handling stool, bowel preparation), which often outranked generic barriers to screening. Not knowing testing was necessary was a top barrier for all tests but colonoscopy. Although physician advice and awareness of the need for screening are important, barriers to screening are not homogenous across tests, and test-specific barriers warrant consideration in designing strategies to improve screening rates. Barrier scores differ by screening status, highlighting the need to address prior screening experience. Evidence that patients are more familiar with colonoscopy than with other modalities suggests an opportunity to improve screening rates by educating patients about alternative tests. 2010 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.
Cumulative Incidence of False-Positive Results in Repeated, Multimodal Cancer Screening
Croswell, Jennifer Miller; Kramer, Barnett S.; Kreimer, Aimee R.; Prorok, Phil C.; Xu, Jian-Lun; Baker, Stuart G.; Fagerstrom, Richard; Riley, Thomas L.; Clapp, Jonathan D.; Berg, Christine D.; Gohagan, John K.; Andriole, Gerald L.; Chia, David; Church, Timothy R.; Crawford, E. David; Fouad, Mona N.; Gelmann, Edward P.; Lamerato, Lois; Reding, Douglas J.; Schoen, Robert E.
2009-01-01
PURPOSE Multiple cancer screening tests have been advocated for the general population; however, clinicians and patients are not always well-informed of screening burdens. We sought to determine the cumulative risk of a false-positive screening result and the resulting risk of a diagnostic procedure for an individual participating in a multimodal cancer screening program. METHODS Data were analyzed from the intervention arm of the ongoing Prostate, Lung, Colorectal, and Ovarian (PLCO) Cancer Screening Trial, a randomized controlled trial to determine the effects of prostate, lung, colorectal, and ovarian cancer screening on disease-specific mortality. The 68,436 participants, aged 55 to 74 years, were randomized to screening or usual care. Women received serial serum tests to detect cancer antigen 125 (CA-125), transvaginal sonograms, posteroanterior-view chest radiographs, and flexible sigmoidoscopies. Men received serial chest radiographs, flexible sigmoidoscopies, digital rectal examinations, and serum prostate-specific antigen tests. Fourteen screening examinations for each sex were possible during the 3-year screening period. RESULTS After 14 tests, the cumulative risk of having at least 1 false-positive screening test is 60.4% (95% CI, 59.8%–61.0%) for men, and 48.8% (95% CI, 48.1%–49.4%) for women. The cumulative risk after 14 tests of undergoing an invasive diagnostic procedure prompted by a false-positive test is 28.5% (CI, 27.8%–29.3%) for men and 22.1% (95% CI, 21.4%–22.7%) for women. CONCLUSIONS For an individual in a multimodal cancer screening trial, the risk of a false-positive finding is about 50% or greater by the 14th test. Physicians should educate patients about the likelihood of false positives and resulting diagnostic interventions when counseling about cancer screening. PMID:19433838
Seidel, G; Münch, I; Dreier, M; Borutta, B; Walter, U; Dierks, M-L
2014-03-01
Evidence-based patient information is an essential part of decision making in health issues. A qualitative study was conducted to examine whether consumers consider the health information on colorectal cancer screening in Germany helpful in supporting their decision making. In this study, eight texts from different German authors about colorectal cancer screening were evaluated with a criteria-based selection. The texts were tested for understandability, structure, design, and effect on readers. Thirteen semi-structured focus groups were formed including 59 higher-educated and 15 lower-educated testers, 46 % of them being male with a mean age of 62.9 years. The transcripts were analyzed by content-analytic assessment. The testers provided detailed comments on the content and design of the texts. They revealed inaccuracies and suggested improvements of the texts. The testers differed from each other in terms of the intensity of their participation in the discussions and comprehension of the material. The reception of the flyers and brochures varied according to the educational level of the testers. Lower-educated testers often skipped passages of texts about risks as well as passages containing numbers and graphics. The texts had different effects on the testers, regardless of the level of education. If adverse effects were presented, some testers became scared while others were reassured because they felt informed. Most of the testers appreciated a call for participation as a central message of the text. Sometimes, if there was no clear appeal to attend the screening, the testers even asked for it. The recently introduced political strategy of promoting an informed choice is applied to an unprepared population who was used to getting a clear yes-or-no recommendation. Thus, at first, the population has to learn how to make an informed choice. This topic must be addressed and taken into account in the process of developing health information. Since this is not always the case, we conclude that current materials are limited in their contribution toward the decision of attending CRC screening.
NASA Flexible Screen Propellant Management Device (PMD) Demonstration With Cryogenic Liquid
NASA Technical Reports Server (NTRS)
Wollen, Mark; Bakke, Victor; Baker, James
2012-01-01
While evaluating various options for liquid methane and liquid oxygen propellant management for lunar missions, Innovative Engineering Solutions (IES) conceived the flexible screen device as a potential simple alternative to conventional propellant management devices (PMD). An apparatus was designed and fabricated to test flexible screen devices in liquid nitrogen. After resolution of a number of issues (discussed in detail in the paper), a fine mesh screen (325 by 2300 wires per inch) spring return assembly was successfully tested. No significant degradation in the screen bubble point was observed either due to the screen stretching process or due to cyclic fatigue during testing. An estimated 30 to 50 deflection cycles, and approximately 3 to 5 thermal cycles, were performed on the final screen specimen, prior to and between formally recorded testing. These cycles included some "abusive" pressure cycling, where gas or liquid was driven through the screen at rates that produced differential pressures across the screen of several times the bubble point pressure. No obvious performance degradation or other changes were observed over the duration of testing. In summary, it is felt by the author that these simple tests validated the feasibility of the flexible screen PMD concept for use with cryogenic propellants.
42 CFR 411.15 - Particular services excluded from coverage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... aneurysms (AAA), cardiovascular disease screening tests, diabetes screening tests, a screening... conditions and limitation specified in § 410.19 of this chapter. (13) In the case of cardiovascular disease screening tests for the early detection of cardiovascular disease or abnormalities associated with an...
Patient Perspectives on Low-Dose Computed Tomography for Lung Cancer Screening, New Mexico, 2014
Sussman, Andrew L.; Murrietta, Ambroshia M.; Getrich, Christina M.; Rhyne, Robert; Crowell, Richard E.; Taylor, Kathryn L.; Reifler, Ellen J.; Wescott, Pamela H.; Saeed, Ali I.; Hoffman, Richard M.
2016-01-01
Introduction National guidelines call for annual lung cancer screening for high-risk smokers using low-dose computed tomography (LDCT). The objective of our study was to characterize patient knowledge and attitudes about lung cancer screening, smoking cessation, and shared decision making by patient and health care provider. Methods We conducted semistructured qualitative interviews with patients with histories of heavy smoking who received care at a Federally Qualified Health Center (FQHC Clinic) and at a comprehensive cancer center-affiliated chest clinic (Chest Clinic) in Albuquerque, New Mexico. The interviews, conducted from February through September 2014, focused on perceptions about health screening, knowledge and attitudes about LDCT screening, and preferences regarding decision aids. We used a systematic iterative analytic process to identify preliminary and emergent themes and to create a coding structure. Results We reached thematic saturation after 22 interviews (10 at the FQHC Clinic, 12 at the Chest Clinic). Most patients were unaware of LDCT screening for lung cancer but were receptive to the test. Some smokers said they would consider quitting smoking if their screening result were positive. Concerns regarding screening were cost, radiation exposure, and transportation issues. To support decision making, most patients said they preferred one-on-one discussions with a provider. They also valued decision support tools (print materials, videos), but raised concerns about readability and Internet access. Conclusion Implementing lung cancer screening in sociodemographically diverse populations poses significant challenges. The value of tobacco cessation counseling cannot be overemphasized. Effective interventions for shared decision making to undergo lung cancer screening will need the active engagement of health care providers and will require the use of accessible decision aids designed for people with low health literacy. PMID:27536900