Long-term pavement performance project laboratory materials testing and handling guide
DOT National Transportation Integrated Search
2007-09-01
The Long Term Pavement Performance (LTPP) Laboratory Material Testing Guide was originally prepared for laboratory material handling and testing of material specimens and samples of asphalt materials, portland cement concrete, aggregates, and soils u...
| Z A Accelerated Exposure Testing Laboratory Advanced Optical Materials Laboratory Advanced Thermal Laboratory Structural Testing Laboratory Surface Analysis Laboratory Systems Performance Laboratory T Thermal Storage Materials Laboratory Thermal Storage Process and Components Laboratory Thin-Film Deposition
High Vacuum Creep Facility in the Materials Processing Laboratory
1973-01-21
Technicians at work in the Materials Processing Laboratory’s Creep Facility at the National Aeronautics and Space Administration (NASA) Lewis Research Center. The technicians supported the engineers’ studies of refractory materials, metals, and advanced superalloys. The Materials Processing Laboratory contained laboratories and test areas equipped to prepare and develop these metals and materials. The ultra-high vacuum lab, seen in this photograph, contained creep and tensile test equipment. Creep testing is used to study a material’s ability to withstand long durations under constant pressure and temperatures. The equipment measured the strain over a long period of time. Tensile test equipment subjects the test material to strain until the material fails. The two tests were used to determine the strength and durability of different materials. The Materials Processing Laboratory also housed arc and electron beam melting furnaces, a hydraulic vertical extrusion press, compaction and forging equipment, and rolling mills and swagers. There were cryogenic and gas storage facilities and mechanical and oil diffusion vacuum pumps. The facility contained both instrumental and analytical chemistry laboratories for work on radioactive or toxic materials and the only shop to machine toxic materials in the Midwest.
Testing of materials from the Minnesota Cold Regions pavement research test facility
DOT National Transportation Integrated Search
1996-09-01
The U.S. Army Cold Regions Research and Engineering Laboratory (CRREL) conducted various laboratory tests on pavement materials from the Mn/ ROAD facility. The tests helped to characterize the behavior of materials under season frost conditions, and ...
Code of Federal Regulations, 2010 CFR
2010-04-01
... I test components, in-process materials, and finished PET drug products? 212.60 Section 212.60 Food... materials, and finished PET drug products? (a) Testing procedures. Each laboratory used to conduct testing of components, in-process materials, and finished PET drug products must have and follow written...
46 CFR 164.009-21 - Laboratory report.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) Description of the specimens tested if the specimens are prepared from composite material. (i) If the test was... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL MATERIALS Noncombustible Materials for Merchant Vessels § 164.009-21 Laboratory...
Diffusion-controlled reference material for VOC emissions testing: proof of concept.
Cox, S S; Liu, Z; Little, J C; Howard-Reed, C; Nabinger, S J; Persily, A
2010-10-01
Because of concerns about indoor air quality, there is growing awareness of the need to reduce the rate at which indoor materials and products emit volatile organic compounds (VOCs). To meet consumer demand for low emitting products, manufacturers are increasingly submitting materials to independent laboratories for emissions testing. However, the same product tested by different laboratories can result in very different emissions profiles because of a general lack of test validation procedures. There is a need for a reference material that can be used as a known emissions source and that will have the same emission rate when tested by different laboratories under the same conditions. A reference material was created by loading toluene into a polymethyl pentene film. A fundamental emissions model was used to predict the toluene emissions profile. Measured VOC emissions profiles using small-chamber emissions tests compared reasonably well to the emissions profile predicted using the emissions model, demonstrating the feasibility of the proposed approach to create a diffusion-controlled reference material. To calibrate emissions test chambers and improve the reproducibility of VOC emission measurements among different laboratories, a reference material has been created using a polymer film loaded with a representative VOC. Initial results show that the film's VOC emission profile measured in a conventional test chamber compares well to predictions based on independently determined material/chemical properties and a fundamental emissions model. The use of such reference materials has the potential to build consensus and confidence in emissions testing as well as 'level the playing field' for product testing laboratories and manufacturers.
Quality Evaluation of Coatings by Automatic Scratch Testing
1989-11-01
MTL TR 89-98 IADII QUALITY EVALUATION OF COATINGS BY AUTOMATIC SCRATCH TESTING KIRIT J. BHANSALI LBRTR A1 U.S. ARMY MATERIALS TECHNOLOGY LABORATORY...distribution unlimited. LABORATORY COMMANO U.S. ARMY MATERIALS TECHNOLOGY LABORATORY PMUNKS wcamaauv LUaAMUv Watertown, Massachusetts 02172-0001 .o...Theo 7- Kattamis* 9 PEWNWING ORGANIZATION NAME AMO ADDRESS 1.PORUEEET RJC.TS AREA & WORK UNIT NUMSS U.S. Army Materials Technology Laboratory Watertown
Fire tests for airplane interior materials
NASA Technical Reports Server (NTRS)
Tustin, E. A.
1980-01-01
Large scale, simulated fire tests of aircraft interior materials were carried out in salvaged airliner fuselage. Two "design" fire sources were selected: Jet A fuel ignited in fuselage midsection and trash bag fire. Comparison with six established laboratory fire tests show that some laboratory tests can rank materials according to heat and smoke production, but existing tests do not characterize toxic gas emissions accurately. Report includes test parameters and test details.
Code of Federal Regulations, 2012 CFR
2012-04-01
... I test components, in-process materials, and finished PET drug products? 212.60 Section 212.60 Food... finished PET drug products? (a) Testing procedures. Each laboratory used to conduct testing of components, in-process materials, and finished PET drug products must have and follow written procedures for the...
Code of Federal Regulations, 2014 CFR
2014-04-01
... I test components, in-process materials, and finished PET drug products? 212.60 Section 212.60 Food... finished PET drug products? (a) Testing procedures. Each laboratory used to conduct testing of components, in-process materials, and finished PET drug products must have and follow written procedures for the...
Code of Federal Regulations, 2013 CFR
2013-04-01
... I test components, in-process materials, and finished PET drug products? 212.60 Section 212.60 Food... finished PET drug products? (a) Testing procedures. Each laboratory used to conduct testing of components, in-process materials, and finished PET drug products must have and follow written procedures for the...
Code of Federal Regulations, 2011 CFR
2011-04-01
... I test components, in-process materials, and finished PET drug products? 212.60 Section 212.60 Food... finished PET drug products? (a) Testing procedures. Each laboratory used to conduct testing of components, in-process materials, and finished PET drug products must have and follow written procedures for the...
Good Laboratory Practices of Materials Testing at NASA White Sands Test Facility
NASA Technical Reports Server (NTRS)
Hirsch, David; Williams, James H.
2005-01-01
An approach to good laboratory practices of materials testing at NASA White Sands Test Facility is presented. The contents include: 1) Current approach; 2) Data analysis; and 3) Improvements sought by WSTF to enhance the diagnostic capability of existing methods.
21 CFR 211.194 - Laboratory records.
Code of Federal Regulations, 2010 CFR
2010-04-01
... specific component, drug product container, closure, in-process material, or drug product, and lot tested... product container, closure, in-process material, or drug product tested. (7) The initials or signature of... of any testing and standardization of laboratory reference standards, reagents, and standard...
46 CFR 164.009-21 - Laboratory report.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 6 2011-10-01 2011-10-01 false Laboratory report. 164.009-21 Section 164.009-21 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL MATERIALS Noncombustible Materials for Merchant Vessels § 164.009-21 Laboratory report. The laboratory report of the test...
46 CFR 164.009-21 - Laboratory report.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 6 2013-10-01 2013-10-01 false Laboratory report. 164.009-21 Section 164.009-21 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL MATERIALS Noncombustible Materials for Merchant Vessels § 164.009-21 Laboratory report. The laboratory report of the test...
46 CFR 164.009-21 - Laboratory report.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 6 2014-10-01 2014-10-01 false Laboratory report. 164.009-21 Section 164.009-21 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL MATERIALS Noncombustible Materials for Merchant Vessels § 164.009-21 Laboratory report. The laboratory report of the test...
46 CFR 164.009-21 - Laboratory report.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 6 2012-10-01 2012-10-01 false Laboratory report. 164.009-21 Section 164.009-21 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL MATERIALS Noncombustible Materials for Merchant Vessels § 164.009-21 Laboratory report. The laboratory report of the test...
Material Transfer Agreement (MTA) | Frederick National Laboratory for Cancer Research
Material Transfer Agreements are appropriate for exchange of materials into or out of the Frederick National Laboratory for research or testing purposes, with no collaborative research by parties involving the materials.
Results of Testing the Relative Oxidizing Hazard of Wipes and KMI Zeolite
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ams, Bridget Elaine
This report includes the results from testing performed on the relative oxidizing hazard of a number of organic sorbing wipe materials, as well as KMI zeolite. These studies were undertaken to address a need by the Los Alamos National Laboratory (LANL) Hazardous Materials Management group, which requires a material that can sorb small spills in a glovebox without creating a disposal hazard due to the potential for oxidation reactions, as requested in Request for Testing of Wipes and Zeolite for Los Alamos National Laboratory Hazardous Materials Group (NPl-7) (NPl-7-17-002) and Request for Testing of Chamois Material for Los Alamos Nationalmore » Laboratory Hazardous Materials Group (NPl-7) (NPl-7-17-005). This set oftests is a continuation of previous testing described in Results from Preparation and Testing of Sorbents Mixed with (DWT-RPT-003), which provided data for the Waste Isolation Pilot Plant's Basis of Knowledge. The Basis of Knowledge establishes criteria for evaluating transuranic (TRU) waste that contains oxidizing chemicals.« less
Integrated Data Collection Analysis (IDCA) Program - RDX Type II Class 5 Standard, Data Set 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.
This document describes the results of the first reference sample material—RDX Type II Class 5—examined in the proficiency study for small-scale safety and thermal (SSST) testing of explosive materials for the Integrated Data Collection Analysis (IDCA) Program. The IDCA program is conducting proficiency testing on homemade explosives (HMEs). The reference sample materials are being studied to establish the accuracy of traditional explosives safety testing for each performing laboratory. These results will be used for comparison to results from testing HMEs. This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of thesemore » materials in perspective with standard military explosives. The results of the study will add SSST testing results for a broad suite of different HMEs to the literature, potentially suggest new guidelines and methods for HME testing, and possibly establish what are the needed accuracies in SSST testing to develop safe handling practices. Described here are the results for impact, friction, electrostatic discharge, and scanning calorimetry analysis of a reference sample of RDX Type II Class 5. The results from each participating testing laboratory are compared using identical test material and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. These results are then compared to historical data from various sources. The performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Air Force Research Laboratory/ RXQL (AFRL), Indian Head Division, Naval Surface Warfare Center, (IHD-NSWC), and Sandia National Laboratories (SNL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when test protocols are not identical.« less
19 CFR 151.54 - Testing by Customs laboratory.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 2 2010-04-01 2010-04-01 false Testing by Customs laboratory. 151.54 Section 151... Other Metal-Bearing Materials § 151.54 Testing by Customs laboratory. Samples taken in accordance with § 151.52 shall be promptly forwarded to the appropriate Customs laboratory for testing in accordance...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 6 2011-10-01 2011-10-01 false Contracting inspections and tests or transferrals to another laboratory or person. 159.010-15 Section 159.010-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS Independent Laboratory...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 6 2010-10-01 2010-10-01 false Contracting inspections and tests or transferrals to another laboratory or person. 159.010-15 Section 159.010-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS Independent Laboratory...
Bartels, Volkmar T
2003-07-01
This study determined the influence of different cover and cushion materials on the thermal comfort of aeroplane seats. Different materials as well as ready made seats were investigated by the physiological laboratory test methods Skin Model and seat comfort tester. Additionally, seat trials with human test subjects were performed in a climatic chamber. Results show that a fabric cover produces a considerably higher sweat transport than leather. A three-dimensional knitted spacer fabric turns out to be the better cushion alternative in comparison to a moulded foam pad. Results from the physiological laboratory test methods nicely correspond to the seat trials with human test subjects.
NASA Technical Reports Server (NTRS)
Turner, J. E.
1993-01-01
An elastomeric O-ring material is used in the joints of the redesigned solid motors (RSRM's) of the National Space Transportation System (NSTS). The selection of the O-ring material used in the RSRM's was a very thorough process that included efforts by NASA's Marshall Space Flight Center and the Langley Research Center, and the Thiokol Corporation. One of the efforts performed at MSFC was an extensive in-house laboratory test regime to screen potential O-ring materials and ultimately to characterize the elastomeric material that was chosen to be used in the RSRM's. The laboratory tests performed at MSFC are summarized.
The Effect of the Laboratory Specimen on Fatigue Crack Growth Rate
NASA Technical Reports Server (NTRS)
Forth, S. C.; Johnston, W. M.; Seshadri, B. R.
2006-01-01
Over the past thirty years, laboratory experiments have been devised to develop fatigue crack growth rate data that is representative of the material response. The crack growth rate data generated in the laboratory is then used to predict the safe operating envelope of a structure. The ability to interrelate laboratory data and structural response is called similitude. In essence, a nondimensional term, called the stress intensity factor, was developed that includes the applied stresses, crack size and geometric configuration. The stress intensity factor is then directly related to the rate at which cracks propagate in a material, resulting in the material property of fatigue crack growth response. Standardized specimen configurations and experimental procedures have been developed for laboratory testing to generate crack growth rate data that supports similitude of the stress intensity factor solution. In this paper, the authors present laboratory fatigue crack growth rate test data and finite element analyses that show similitude between standard specimen configurations tested using the constant stress ratio test method is unobtainable.
1999-09-01
Harrington , showed that with respect to mixed water analysis containing TDS at greater 1,000 ppm, the performance of the AS-5 column is not as robust...to note, these raw test materials were heterogeneous. Regardless of mixing time and mesh quality, dividing the raw test materials for laboratory...raw test material was prepared and shipped to seven laboratories for blind analysis. The suspension was prepared by 4 mixing the solid sample with
NASA Technical Reports Server (NTRS)
1993-01-01
A description is given of each of the following Langley research and test facilities: 0.3-Meter Transonic Cryogenic Tunnel, 7-by 10-Foot High Speed Tunnel, 8-Foot Transonic Pressure Tunnel, 13-Inch Magnetic Suspension & Balance System, 14-by 22-Foot Subsonic Tunnel, 16-Foot Transonic Tunnel, 16-by 24-Inch Water Tunnel, 20-Foot Vertical Spin Tunnel, 30-by 60-Foot Wind Tunnel, Advanced Civil Transport Simulator (ACTS), Advanced Technology Research Laboratory, Aerospace Controls Research Laboratory (ACRL), Aerothermal Loads Complex, Aircraft Landing Dynamics Facility (ALDF), Avionics Integration Research Laboratory, Basic Aerodynamics Research Tunnel (BART), Compact Range Test Facility, Differential Maneuvering Simulator (DMS), Enhanced/Synthetic Vision & Spatial Displays Laboratory, Experimental Test Range (ETR) Flight Research Facility, General Aviation Simulator (GAS), High Intensity Radiated Fields Facility, Human Engineering Methods Laboratory, Hypersonic Facilities Complex, Impact Dynamics Research Facility, Jet Noise Laboratory & Anechoic Jet Facility, Light Alloy Laboratory, Low Frequency Antenna Test Facility, Low Turbulence Pressure Tunnel, Mechanics of Metals Laboratory, National Transonic Facility (NTF), NDE Research Laboratory, Polymers & Composites Laboratory, Pyrotechnic Test Facility, Quiet Flow Facility, Robotics Facilities, Scientific Visualization System, Scramjet Test Complex, Space Materials Research Laboratory, Space Simulation & Environmental Test Complex, Structural Dynamics Research Laboratory, Structural Dynamics Test Beds, Structures & Materials Research Laboratory, Supersonic Low Disturbance Pilot Tunnel, Thermal Acoustic Fatigue Apparatus (TAFA), Transonic Dynamics Tunnel (TDT), Transport Systems Research Vehicle, Unitary Plan Wind Tunnel, and the Visual Motion Simulator (VMS).
Phinney, Karen W; Sempos, Christopher T; Tai, Susan S-C; Camara, Johanna E; Wise, Stephen A; Eckfeldt, John H; Hoofnagle, Andrew N; Carter, Graham D; Jones, Julia; Myers, Gary L; Durazo-Arvizu, Ramon; Miller, W Greg; Bachmann, Lorin M; Young, Ian S; Pettit, Juanita; Caldwell, Grahame; Liu, Andrew; Brooks, Stephen P J; Sarafin, Kurtis; Thamm, Michael; Mensink, Gert B M; Busch, Markus; Rabenberg, Martina; Cashman, Kevin D; Kiely, Mairead; Galvin, Karen; Zhang, Joy Y; Kinsella, Michael; Oh, Kyungwon; Lee, Sun-Wha; Jung, Chae L; Cox, Lorna; Goldberg, Gail; Guberg, Kate; Meadows, Sarah; Prentice, Ann; Tian, Lu; Brannon, Patsy M; Lucas, Robyn M; Crump, Peter M; Cavalier, Etienne; Merkel, Joyce; Betz, Joseph M
2017-09-01
The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme. Study protocols and data analysis procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. The majority of the test materials were found to be commutable with the methods used in this commutability study. These results provide guidance for laboratories needing to choose appropriate reference materials and select proficiency or external quality assessment programs and will serve as a foundation for additional VDSP studies.
46 CFR 159.007-3 - Production inspections and tests: Independent laboratory's procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 6 2011-10-01 2011-10-01 false Production inspections and tests: Independent laboratory's procedures. 159.007-3 Section 159.007-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS Production Inspection and Tests of...
46 CFR 159.007-3 - Production inspections and tests: Independent laboratory's procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 6 2010-10-01 2010-10-01 false Production inspections and tests: Independent laboratory's procedures. 159.007-3 Section 159.007-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND MATERIALS Production Inspection and Tests of...
Leaching assessment of road materials containing primary lead and zinc slags.
Barna, R; Moszkowicz, P; Gervais, C
2004-01-01
Characterisation of the leaching behaviour of waste-containing materials is a crucial step in the environmental assessment for reuse scenarios. In our research we applied the multi-step European methodology ENV 12-920 to the leaching assessment of road materials containing metallurgical slag. A Zn slag from an imperial smelting furnace (ISF) and a Pb slag from a lead blast furnace (LBF) are investigated. The two slags contain up to 11.2 wt% of lead and 3.5 wt% of zinc and were introduced as a partial substitute for sand in two road materials, namely sand-cement and sand-bitumen. At the laboratory scale, a leaching assessment was performed first through batch equilibrium leaching tests. Second, the release rate of the contaminants was evaluated using saturated leaching tests on monolithic material. Third, laboratory tests were conducted on monolithic samples under intermittent wetting conditions. Pilot-scale tests were conducted for field testing of intermittent wetting conditions. The results show that the release of Pb and Zn from the materials in a saturated scenario was controlled by the pH of the leachates. For the intermittent wetting conditions, an additional factor, blocking of the pores by precipitation during the drying phase is proposed. Pilot-scale leaching behaviour only partially matched with the laboratory-scale test results: new mass transfer mechanisms and adapted laboratory leaching tests are discussed.
DOT National Transportation Integrated Search
2015-04-01
The objective of this research was to identify a laboratory test method that can be used to quantify improvements in structural capacity of aggregate base materials reinforced with geogrid. For this research, National Cooperative Highway Research Pro...
RUBBER BEARINGS FOR DOWN-HOLE PUMPS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bob Sullivan Mammoth Pacific, L.P.
2005-09-07
Synopsis of project activity: 1998--Awarded cost share grant from DOE. 1st Qtr 1999--Developed fail safe lubricating system. 2nd Qtr 1999--Performed first large scale test with nitrile based bearings. It failed due to material swelling. Failure was blamed on improper tolerance. 3rd Qtr 1999--Material tests were performed with autoclaves and exposure tests to Casa Diablo fluids. Testing of Viton materials began. Alternate bearing designs were developed to limit risk of improper tolerances. 4th Qtr 1999--Site testing indicated a chemical attack on the bearing material caused the test failure and not improper bearing tolerance. 1st Qtr 2000--The assistance of Brookhaven National Laboratorymore » was obtained in evaluating the chemical attack. The National Laboratory also began more elaborate laboratory testing on bearing materials. 2nd Qtr 2000--Testing indicated Viton was an inappropriate material due to degradation in Casa Diablo fluid. Testing of EPDM began. 3rd Qtr 2001--EPDM bearings were installed for another large scale test. Bearings failed again due to swelling. Further testing indicated that larger then expected oil concentrations existed in lubricating water geothermal fluid causing bearing failure. 2002-2003--Searched for and tested several materials that would survive in hot salt and oil solutions. Kalrez{reg_sign}, Viton{reg_sign}ETP 500 and Viton{reg_sign}GF were identified as possible candidates. 2003-2005--Kalrez{reg_sign}has shown superior resistance to downhole conditions at Casa Diablo from among the various materials tested. Viton ETP-500 indicated a life expectancy of 13 years and because it is significantly less expensive then Kalrez{reg_sign}, it was selected as the bearing material for future testing. Unfortunately during the laboratory testing period Dupont Chemical chose to stop manufacturing this specific formulation and replaced it with Viton ETP 600S. The material is available with six different fillers; three based on zinc oxide and three based on silicon oxide. Samples of all six materials have been obtained and are being tested at the National Laboratory in Brookhaven, New York. This new material's properties as a bearing material and its ability to adhere to a bearings shell must be reviewed, but cost information deemed the material to be too expensive to be economical.« less
REACTOR SERVICES BUILDING, TRA635, INTERIOR. ALSO KNOWN AS MATERIAL RECEIVING ...
REACTOR SERVICES BUILDING, TRA-635, INTERIOR. ALSO KNOWN AS MATERIAL RECEIVING AREA AND LABORATORY. CAMERA ON FIRST FLOOR FACING NORTH TOWARD MTR BUILDING. MOCK-UP AREA WAS TO THE RIGHT OF VIEW. INL NEGATIVE NO. HD46-10-1. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
NASA Technical Reports Server (NTRS)
1993-01-01
Trace Laboratories is an independent testing laboratory specializing in testing printed circuit boards, automotive products and military hardware. Technical information from NASA Tech Briefs and two subsequent JPL Technical Support packages have assisted Trace in testing surface insulation resistance on printed circuit board materials. Testing time was reduced and customer service was improved because of Jet Propulsion Laboratory technical support packages.
Advanced Materials Laboratory User Test Planning Guide
NASA Technical Reports Server (NTRS)
Orndoff, Evelyne
2012-01-01
Test process, milestones and inputs are unknowns to first-time users of the Advanced Materials Laboratory. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.
NASA Astrophysics Data System (ADS)
Longdon, Norman; Dauphin, J.; Dunn, B. D.; Judd, M. D.; Levadou, F. G.; Zwaal, A.
1992-04-01
This booklet is addressed to the users of the Materials and Processes Laboratories of the European Space Research and Technology Centre (ESTEC). The revised edition updates the July 1988 edition featuring the enhancement of existing laboratories and the establishment of a ceramics laboratory. Information on three ESTEC laboratories is presented as well as a look into the future. The three laboratories are the Environmental Effects Laboratory, the Metallic Materials Laboratory, and the Non-metallic Laboratory. The booklet reports on the effects of the space environment on radiation effects (UV and particles), outgassing and contamination, charging-up and discharges, particulate contaminants, atomic oxygen and debris/impacts. Applications of metallic materials to space hardware are covered in the areas of mechanical properties, corrosion/stress corrosion, fracture testing and interpretation, metallurgical processes and failure analysis. Particular applications of non metallic materials to space hardware that are covered are advanced and reinforced polymers, advanced ceramics, thermal properties, manned ambiance, polymer processing, non-destructive tests (NDT), and failure analysis. Future emphasis will be on the measurement of thermo-optical properties for the Infrared Space Observatory (ISO) and other infrared telescopes, support of the Columbus program, Hermes related problems such as 'warm' composites and 'hot' reinforced ceramics for thermal insulation, materials for extravehicular activity (EVA), and NDT.
Laboratory test methods for evaluating the fire response of aerospace materials
NASA Technical Reports Server (NTRS)
Hilado, C. J.
1979-01-01
The test methods which were developed or evaluated were intended to serve as means of comparing materials on the basis of specific responses under specific sets of test conditions, using apparatus, facilities, and personnel that would be within the capabilities of perhaps the majority of laboratories. Priority was given to test methods which showed promise of addressing the pre-ignition state of a potential fire. These test methods were intended to indicate which materials may present more hazard than others under specific test conditions. These test methods are discussed and arranged according to the stage of a fire to which they are most relevant. Some observations of material performance which resulted from this work are also discussed.
19 CFR 151.12 - Accreditation of commercial laboratories.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., published by such organizations as the American Society for Testing and Materials (ASTM) and the American... American Society for Testing and Materials (ASTM) E548 (Standard Guide for General Criteria Used for... bachelor's degree in science or have two years related experience in an analytical laboratory. (g) How will...
19 CFR 151.12 - Accreditation of commercial laboratories.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., published by such organizations as the American Society for Testing and Materials (ASTM) and the American... American Society for Testing and Materials (ASTM) E548 (Standard Guide for General Criteria Used for... bachelor's degree in science or have two years related experience in an analytical laboratory. (g) How will...
19 CFR 151.12 - Accreditation of commercial laboratories.
Code of Federal Regulations, 2012 CFR
2012-04-01
..., published by such organizations as the American Society for Testing and Materials (ASTM) and the American... American Society for Testing and Materials (ASTM) E548 (Standard Guide for General Criteria Used for... bachelor's degree in science or have two years related experience in an analytical laboratory. (g) How will...
19 CFR 151.12 - Accreditation of commercial laboratories.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., published by such organizations as the American Society for Testing and Materials (ASTM) and the American... American Society for Testing and Materials (ASTM) E548 (Standard Guide for General Criteria Used for... bachelor's degree in science or have two years related experience in an analytical laboratory. (g) How will...
19 CFR 151.12 - Accreditation of commercial laboratories.
Code of Federal Regulations, 2011 CFR
2011-04-01
..., published by such organizations as the American Society for Testing and Materials (ASTM) and the American... American Society for Testing and Materials (ASTM) E548 (Standard Guide for General Criteria Used for... bachelor's degree in science or have two years related experience in an analytical laboratory. (g) How will...
Permeation Tests on Polypropylene Fiber Materials
2018-03-16
Engineering at the Naval Research Laboratory (NRL) evaluated polypropylene nanofiber materials for their potential in air filtration to remove toxic......The Center for Bio/Molecular Science and Engineering at the Naval Research Laboratory (NRL) evaluated polypropylene nanofiber materials provided by
Code of Federal Regulations, 2010 CFR
2010-01-01
... in vitro clinical or laboratory testing. 31.11 Section 31.11 Energy NUCLEAR REGULATORY COMMISSION... certain in vitro clinical or laboratory testing. (a) A general license is hereby issued to any physician, veterinarian in the practice of veterinary medicine, clinical laboratory or hospital to receive, acquire...
MATERIALS TESTING REACTOR (MTR) BUILDING, TRA603. CONTEXTUAL VIEW OF MTR ...
MATERIALS TESTING REACTOR (MTR) BUILDING, TRA-603. CONTEXTUAL VIEW OF MTR BUILDING SHOWING NORTH SIDES OF THE HIGH-BAY REACTOR BUILDING, ITS SECOND/THIRD FLOOR BALCONY LEVEL, AND THE ATTACHED ONE-STORY OFFICE/LABORATORY BUILDING, TRA-604. CAMERA FACING SOUTHEAST. VERTICAL CONCRETE-SHROUDED BEAMS SUPPORT PRECAST CONCRETE PANELS. CONCRETE PROJECTION FORMED AS A BUNKER AT LEFT OF VIEW IS TRA-657, PLUG STORAGE BUILDING. INL NEGATIVE NO. HD46-42-1. Mike Crane, Photographer, 4/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
NASA Astrophysics Data System (ADS)
Reynolds, John; Sandstrom, Mary; Brown, Geoffrey; Warner, Kirstin; Phillips, Jason; Shelley, Timothy; Reyes, Jose; Hsu, Peter
2013-06-01
One of the first steps in establishing safe handling procedures for explosives is small-scale safety and thermal (SSST) testing. To better understand the response of improvised materials or HMEs to SSST testing, 18 HME materials were compared to 3 standard military explosives in a proficiency-type round robin study among five laboratories--2 DoD and 3 DOE--sponsored by DHS. The testing matrix has been designed to address problems encountered with improvised materials--powder mixtures, liquid suspensions, partially wetted solids, immiscible liquids, and reactive materials. Over 30 issues have been identified that indicate standard test methods may require modification when applied to HMEs to derive accurate sensitivity assessments needed for development safe handling and storage practices. This presentation will discuss experimental difficulties encountered when testing these problematic samples, show inter-laboratory testing results, show some statistical interpretation of the results, and highlight some of the testing issues. Some of the work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. LLNL-ABS-617519 (721812).
ERIC Educational Resources Information Center
Schumacher, Susan J.
1982-01-01
A laboratory project introduced physiological psychology students to research by requiring them to identify an unknown drug given to laboratory animals. Students read material about drugs and animal drug studies, designed behavioral tests, constructed the testing apparatus, conducted the tests, and wrote progress reports. (SR)
A comparison of relative toxicity rankings by some small-scale laboratory tests
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Cumming, H. J.
1977-01-01
Small-scale laboratory tests for fire toxicity, suitable for use in the average laboratory hood, are needed for screening and ranking materials on the basis of relative toxicity. The performance of wool, cotton, and aromatic polyamide under several test procedures is presented.
Resilient modulus testing of materials from MN/Road : phase 1
DOT National Transportation Integrated Search
1996-09-01
The U.S. Army Cold Regions Research and Engineering Laboratory (CRREL) conducted resilient modulus tests on materials from the MN/ROAD test site for the Minnesota Department of Transportation. Materials tested included samples of the lean clay subgra...
Guidelines to Language Teaching in Classroom and Laboratory.
ERIC Educational Resources Information Center
Iodice, Don R.
Guidelines for evaluating, establishing, and administrating classroom and laboratory language programs are offered in this report. Attention is focused on the language laboratory, with sections on its use, scheduling, materials and texts, preparation of audio materials, preparation of tests, supervision, discipline, and maintenance. Briefer…
MTR WING A, TRA604, INTERIOR. MAIN FLOOR. DETAIL VIEW INSIDE ...
MTR WING A, TRA-604, INTERIOR. MAIN FLOOR. DETAIL VIEW INSIDE LABORATORY 114. CAMERA FACING NORTH. DISPOSAL OF RADIOACTIVE MATERIALS IS UNDERWAY. INL NEGATIVE NO. HD46-12-4. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Mudflow utilization for construction materials of tertiary irrigation canal lining
NASA Astrophysics Data System (ADS)
Azis, Subandiyah; Kustamar
2017-11-01
Mudflow in Siring Village, Sidoarjo Regency, Indonesia, has been in eruption since May 29, 2006. It still shows irregular large bursts which loaded in a sludge reservoir with capacity of 59 million m3. From 2007 until 2015, there were more than 20 studies which concluded that the mudflow could be used as a mixture of building materials. However, the studies were not detailed and needed further research. This research aims to investigate the use of mudflow as tertiary irrigation canal lining material. This research comes with several laboratory tests to obtain a mixture that is solid and water-resistant. The methods that were used are descriptive methods as follows: 1). Sampling of mudflow, to be analyzed in Material Testing Laboratory. 2). Sampling of soil at research site, to be analyzed in Soil Mechanics Laboratory 3). Mixing of materials which are consist of mudflow and other materials and doing strength test in the laboratory. 4). Installation of tertiary irrigation canal lining using materials that have been tested. 5). Observation of lining's strength inactive soil pressure-bearing and its impermeability. It is expected that the results of this research will be applied extensively throughout the tertiary irrigation canals, so mudflow can be utilized as raw materials that are environmentally friendly, which are able to help preserving the environment, also to reduce the removal of sand / rock in the river, which has been used for lining materials, that benefits in preventing damage to the river ecosystem.
33 CFR 209.340 - Laboratory investigations and materials testing.
Code of Federal Regulations, 2010 CFR
2010-07-01
... hydraulic laboratories, and to the Inter-Agency Sedimentation Project. (c) References. (1) AR 37-20. (2) AR... ordinary business channels. (3) Performance of the work will not interfere with provisions of services... with the same procedures as apply to Division Materials Laboratories. (3) Inter-Agency Sedimentation...
33 CFR 209.340 - Laboratory investigations and materials testing.
Code of Federal Regulations, 2011 CFR
2011-07-01
... hydraulic laboratories, and to the Inter-Agency Sedimentation Project. (c) References. (1) AR 37-20. (2) AR... ordinary business channels. (3) Performance of the work will not interfere with provisions of services... with the same procedures as apply to Division Materials Laboratories. (3) Inter-Agency Sedimentation...
NASA Astrophysics Data System (ADS)
Lander, Michael L.
2003-05-01
The Laser Hardened Materials Evaluation Laboratory (LHMEL) has been characterizing material responses to laser energy in support of national defense programs and the aerospace industry for the past 26 years. This paper reviews the overall resources available at LHMEL to support fundamental materials testing relating to impulse coupling measurement and to explore beamed energy launch concepts. Located at Wright-Patterson Air Force Base, Ohio, LHMEL is managed by the Air Force Research Laboratory Materials Directorate AFRL/MLPJ and operated by Anteon Corporation. The facility's advanced hardware is centered around carbon dioxide lasers producing output power up to 135kW and neodymium glass lasers producing up to 10 kilojoules of repetitively pulsed output. The specific capabilities of each laser device and related optical systems are discussed. Materials testing capabilities coupled with the laser systems are also described including laser output and test specimen response diagnostics. Environmental simulation capabilities including wind tunnels and large-volume vacuum chambers relevant to beamed energy propulsion are also discussed. This paper concludes with a summary of the procedures and methods by which the facility can be accessed.
Evaluation of Minimum Asphalt Concrete Thickness Criteria
2008-10-01
9 Figure 6. Dry density versus moisture content for CH material... density measurements. ............................ 24 Figure 18. EPC installation in a crushed gravel base course layer...Construction Materials Materials Characterization Laboratory Testing Field Testing Test Section Construction Hydrometer, Modified Proctor , Specific
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Casey, C. J.; Kourtides, D. A.; Parker, J. A.
1977-01-01
Approximately 300 materials were evaluated using a specific set of test conditions. Materials tested included wood, fibers, fabrics and synthetic polymers. Data obtained using 10 different sets of test conditions are presented.
10 CFR 431.18 - Testing laboratories.
Code of Federal Regulations, 2010 CFR
2010-01-01
... EQUIPMENT Electric Motors Test Procedures, Materials Incorporated and Methods of Determining Efficiency... Technology/National Voluntary Laboratory Accreditation Program (NIST/NVLAP); or (2) A laboratory... of the National Institute of Standards and Technology (NIST) which is part of the U.S. Department of...
Zhou, Joseph Ziqi; Waszkuc, Ted; Mohammed, Felicia
2008-01-01
A collaborative study was conducted for determination of glucosamine in raw materials and dietary supplements containing glucosamine sulfate and/or glucosamine hydrochloride by high-performance liquid Chromatography (HPLC) with N-(9-fluorenyl-methoxycarbonyloxy) succinimide (FMOC-Su) derivatization. Thirteen blind materials, one pair of which were duplicates, were tested by 12 collaborating laboratories. The test samples consisted of various commercial products, including tablets, capsules, drink mix, and liquids as well as raw materials, blanks, and those for spike recovery analyses. The tests with blank products and products spiked with glucosamine showed good specificity of the method. The average recoveries at spike levels of 100 and 150% of the declared amount were 99.0% with a relative standard deviation (RSD) of 2.1%, and 101% with an RSD of 2.3%, respectively. The test results between laboratories on each commercial product were reproducible with RSD values of no more than 4.0%, and the results were repeatable in the same laboratory with an average RSD of 0.7%. HorRat values ranged from 0.5 to 1.7 on both tests of spike recovery and reproducibility between laboratories on commercial products. The average determination coefficient of the calibration curves from the laboratories was 0.9995 with an RSD of 0.03%. All of the 12 collaborating laboratories succeeded in the study and none of their reported test results were outliers, partly indicating the robustness of the method. It is recommended that the method be accepted by AOAC INTERNATIONAL as Official First Action. PMID:16152919
NASA Technical Reports Server (NTRS)
Gordon, Gail
2012-01-01
The Materials Test Branch resides at Marshall Space Flight Center's Materials and Processing laboratory and has a long history of supporting NASA programs from Mercury to the recently retired Space Shuttle. The Materials Test Branch supports its customers by supplying materials testing expertise in a wide range of applications. The Materials Test Branch is divided into three Teams, The Chemistry Team, The Tribology Team and the Mechanical Test Team. Our mission and goal is to provide world-class engineering excellence in materials testing with a special emphasis on customer service.
SRB Materials and Processes Assessment from Laboratory and Ocean Environmental Tests
NASA Technical Reports Server (NTRS)
1978-01-01
The Materials and Processes Laboratory evaluation of Solid Rocket Boosters (SRB) and Solid Rocket Motors (SRM) candidate material, both in-house and with ocean exposure tests at Panama City and Kennedy Space Center (KSC), Florida is presented. Early sample tests showed excellent seawater corrosion resistance for inconel 718 and titanium 6A1-4V alloys. Considerable corrosion and biofouling occurred with bare 2219-T87 aluminum. Subsequent tests conclusively demonstrated that epoxy coatings prevented corrosion of 2219-T87 aluminum as long as the coatings stays intact. The results and assessment of the series of ocean environmental tests that were conducted are also presented.
1983-12-01
Maximum Site site length Earthquake Accelerations Fault (miles) (miles) (Magnitude) in Bedrock (g)* Agua Caliente 32 50 7.25 0.13 Calico-Newberry 56 50...disturbed samples of representative materials were - obtained for laboratory testing. Seventeen inr- situ density tests were * conducted in the excavated...disturbed samples of representative materials were obtained for - --.-- laboratory testing. Four in- situ density tests were conducted in the trenches by the
Integrated Data Collection Analysis (IDCA) program--KClO 4/Dodecane Mixture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.
The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of a mixture of KClO 4 and dodecane—KClO 4/dodecane mixture. This material was selected because of the challenge of performing SSST testing of a mixture of solid and liquid materials. The mixture was found to: 1) be less sensitive to impact than RDX, and PETN, 2) less sensitive to friction than RDX and PETN, and 3) less sensitive to spark thanmore » RDX and PETN. The thermal analysis showed little or no exothermic features suggesting that the dodecane volatilized at low temperatures. A prominent endothermic feature was observed and assigned to a phase transition of KClO 4. This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study has the potential to suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. The results are compared among the laboratories and then compared to historical data from various sources. The testing performers involved for the KClO 4/dodecane mixture are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when these testing variables cannot be made consistent.« less
Code of Federal Regulations, 2010 CFR
2010-01-01
... certain in vitro clinical or laboratory testing under general license. 32.71 Section 32.71 Energy NUCLEAR... certain in vitro clinical or laboratory testing under general license. An application for a specific... only by physicians, veterinarians in the practice of veterinary medicine, clinical laboratories or...
42 CFR 493.1255 - Standard: Calibration and calibration verification procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... accuracy of the test system throughout the laboratory's reportable range of test results for the test system. Unless otherwise specified in this subpart, for each applicable test system the laboratory must... test system instructions, using calibration materials provided or specified, and with at least the...
Blackwood, Kym S; Burdz, Tamara V; Turenne, Christine Y; Sharma, Meenu K; Kabani, Amin M; Wolfe, Joyce N
2005-01-24
In the field of clinical mycobacteriology, Mycobacterium tuberculosis (MTB) can be a difficult organism to manipulate due to the restrictive environment of a containment level 3 (CL3) laboratory. Tests for rapid diagnostic work involving smears and molecular methods do not require CL3 practices after the organism has been rendered non-viable. While it has been assumed that after organism deactivation these techniques can be performed outside of a CL3, no conclusive study has consistently confirmed that the organisms are noninfectious after the theoretical 'deactivation' steps. Previous studies have shown that initial steps (such as heating/chemical fixation) may not consistently kill MTB organisms. An inclusive viability study (n = 226) was undertaken to determine at which point handling of culture extraction materials does not necessitate a CL3 environment. Four different laboratory protocols tested for viability included: standard DNA extractions for IS6110 fingerprinting, crude DNA preparations for PCR by boiling and mechanical lysis, protein extractions, and smear preparations. For each protocol, laboratory staff planted a proportion of the resulting material to Bactec 12B medium that was observed for growth for 8 weeks. Of the 208 isolates initially tested, 21 samples grew within the 8-week period. Sixteen (7.7%) of these yielded positive results for MTB that included samples of: deactivated culture resuspensions exposed to 80 degrees C for 20 minutes, smear preparations and protein extractions. Test procedures were consequently modified and tested again (n = 18), resulting in 0% viability. This study demonstrates that it cannot be assumed that conventional practices (i.e. smear preparation) or extraction techniques render the organism non-viable. All methodologies, new and existing, should be examined by individual laboratories to validate the safe removal of material derived from MTB to the outside of a CL3 laboratory. This process is vital to establish in house biosafety-validated practices with the aim of protecting laboratory workers conducting these procedures.
Pratt, Victoria M.; Zehnbauer, Barbara; Wilson, Jean Amos; Baak, Ruth; Babic, Nikolina; Bettinotti, Maria; Buller, Arlene; Butz, Ken; Campbell, Matthew; Civalier, Chris; El-Badry, Abdalla; Farkas, Daniel H.; Lyon, Elaine; Mandal, Saptarshi; McKinney, Jason; Muralidharan, Kasinathan; Noll, LeAnne; Sander, Tara; Shabbeer, Junaid; Smith, Chingying; Telatar, Milhan; Toji, Lorraine; Vairavan, Anand; Vance, Carlos; Weck, Karen E.; Wu, Alan H.B.; Yeo, Kiang-Teck J.; Zeller, Markus; Kalman, Lisa
2010-01-01
Pharmacogenetic testing is becoming more common; however, very few quality control and other reference materials that cover alleles commonly included in such assays are currently available. To address these needs, the Centers for Disease Control and Prevention's Genetic Testing Reference Material Coordination Program, in collaboration with members of the pharmacogenetic testing community and the Coriell Cell Repositories, have characterized a panel of 107 genomic DNA reference materials for five loci (CYP2D6, CYP2C19, CYP2C9, VKORC1, and UGT1A1) that are commonly included in pharmacogenetic testing panels and proficiency testing surveys. Genomic DNA from publicly available cell lines was sent to volunteer laboratories for genotyping. Each sample was tested in three to six laboratories using a variety of commercially available or laboratory-developed platforms. The results were consistent among laboratories, with differences in allele assignments largely related to the manufacturer's assay design and variable nomenclature, especially for CYP2D6. The alleles included in the assay platforms varied, but most were identified in the set of 107 DNA samples. Nine additional pharmacogenetic loci (CYP4F2, EPHX1, ABCB1, HLAB, KIF6, CYP3A4, CYP3A5, TPMT, and DPD) were also tested. These samples are publicly available from Coriell and will be useful for quality assurance, proficiency testing, test development, and research. PMID:20889555
Integrated Data Collection Analysis (IDCA) Program - KClO 4/Carbon Mixture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.
The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of a mixture of KClO 4 and activated carbon—KClO 4/C mixture. This material was selected because of the challenge of performing SSST testing of a mixture of two solids. The mixture was found to be insensitive to impact, friction, and thermal stimulus, and somewhat sensitive to spark discharge. This effort, funded by the Department of Homeland Security (DHS), ultimately will putmore » the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study has the potential to suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. The results are compared among the laboratories and then compared to historical data from various sources. The testing performers involved for the KClO 4/carbon mixture are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when these testing variables cannot be made consistent.« less
NASA Technical Reports Server (NTRS)
Minow, Josep I.; Edwards, David L.
2008-01-01
Qualifying materials for use in the space environment is typically accomplished with laboratory exposures to simulated UV/EUV, atomic oxygen, and charged particle radiation environments with in-situ or subsequent measurements of material properties of interest to the particular application. Choice of environment exposure levels are derived from static design environments intended to represent either mean or extreme conditions that are anticipated to be encountered during a mission. The real space environment however is quite variable. Predictions of the on orbit performance of a material qualified to laboratory environments can be done using information on 'space weather' variations in the real environment. This presentation will first review the variability of space environments of concern for material degradation and then demonstrate techniques for using test data to predict material performance in a variety of space environments from low Earth orbit to interplanetary space using historical measurements and space weather models.
Webster, Gregory K; Marsden, Ian; Pommerening, Cynthia A; Tyrakowski, Christina M
2010-05-01
With the changing development paradigms in the pharmaceutical industry, laboratories are challenged to release materials for clinical studies with rapid turnaround times. To minimize cost demands, many businesses are looking to develop ways of using early Good Manufacturing Practice (GMP) materials of active pharmaceutical ingredients (API) for Good Laboratory Practice (GLP) toxicology studies. To make this happen, the analytical laboratory releases the material by one of three scenarios: (1) holding the GLP release until full GMP testing is ready, (2) issuing a separate lot number for a portion of the GMP material and releasing the material for GLP use, or (3) releasing the lot of material for GLP using alternate (equivalent) method(s) not specified for GMP release testing. Many companies are finding the third scenario to be advantageous in terms of cost and efficiency through the use of quantitative nuclear magnetic resonance (q-NMR). The use of q-NMR has proved to be a single-point replacement for routine early development testing that previously combined elements of identity testing, chromatographic assay, moisture analysis, residual solvent analysis, and elemental analysis. This study highlights that q-NMR can be validated to meet current regulatory analytical method guidelines for routine pharmaceutical analysis.
Pulsed-laser capabilities at the Laser-Hardened Materials Evaluation Laboratory (LHMEL)
NASA Astrophysics Data System (ADS)
Royse, Robert W.; Seibert, Daniel B., II; Lander, Michael L.; Eric, John J.
2000-08-01
Pulsed laser capabilities at the Laser Hardened Material Evaluation Laboratory are described relevant to optical coupling, impulse generation and laser propulsion. Capabilities of the Nd:Glass laser are presented as well as supporting test systems.
Tests to Help Plan Opportunity Moves
2005-05-06
Rover engineers check how a test rover moves in material chosen to simulate some difficult Mars driving conditions. The scene is inside the In-Situ Instrument Laboratory at NASA Jet Propulsion Laboratory, Pasadena, Calif.
Camus, Melinda S; Flatland, Bente; Freeman, Kathleen P; Cruz Cardona, Janice A
2015-12-01
The purpose of this document is to educate providers of veterinary laboratory diagnostic testing in any setting about comparative testing. These guidelines will define, explain, and illustrate the importance of a multi-faceted laboratory quality management program which includes comparative testing. The guidelines will provide suggestions for implementation of such testing, including which samples should be tested, frequency of testing, and recommendations for result interpretation. Examples and a list of vendors and manufacturers supplying control materials and services to veterinary laboratories are also included. © 2015 American Society for Veterinary Clinical Pathology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chiaro, PJ
The Environmental Effects Laboratory of the Engineering Science and Technology Division of Oak Ridge National Laboratory performed a series of tests to further evaluate and characterize the radiological response of a ''Cricket'' radiation detection system. The Cricket, manufactured by Rad/Comm Systems Corporation of Ontario, Canada, is designed to detect radioactive material that may be contained in scrap metal. The Cricket's detection unit is designed to be mounted to the base of a grappler, allowing it to monitor material while the material is being held by the grappler tines. The Cricket was tested for background stability, energy response, spherical response, surfacemore » uniformity, angular dependence, and alarm actuation. Some of these tests were repeated from a prior test of a Cricket at the Environmental Effects Laboratory as reported in ORNL/TM-2002/94. Routine environmental tests--normal temperature and relatively humidity--were also performed as part of this testing process. Overall, the Cricket performed well during the testing process. The design of the instrument and the inherent photon energy of the radionuclides had some affect on portions of the tests but do not detract from the value-added benefits of the Cricket's detection capabilities.« less
Thue, Geir; Jevnaker, Marianne; Gulstad, Guri Andersen; Sandberg, Sverre
2011-09-01
Virtually all the general practices in Norway participate in the Norwegian Quality Improvement of Laboratory Services in Primary Care, NOKLUS. In order to assess and develop NOKLUS's services, it was decided to carry out an investigation in the largest participating group, general practices. In autumn 2008 a questionnaire was sent to all Norwegian general practices asking for feedback on different aspects of NOKLUS's main services: contact with medical laboratory technologists, sending of control materials, use and maintenance of practice-specific laboratory binders, courses, and testing of laboratory equipment. In addition, attitudes were elicited towards possible new services directed at assessing other technical equipment and clinical use of tests. Responses were received from 1290 of 1552 practices (83%). The great majority thought that the frequency of sending out control material should continue as at present, and they were pleased with the feedback reports and follow-up by the laboratory technologists in the counties. Even after many years of practical experience, there is still a need to update laboratory knowledge through visits to practices, courses, and written information. Practices also wanted quality assurance of blood pressure meters and spirometers, and many doctors wanted feedback on their use of laboratory tests. Services regarding quality assurance of point-of-care tests, guidance, and courses should be continued. Quality assurance of other technical equipment and of the doctor's clinical use of laboratory tests should be established as part of comprehensive quality assurance.
NASA Astrophysics Data System (ADS)
Reynolds, J. G.; Sandstrom, M. M.; Brown, G. W.; Warner, K. F.; Phillips, J. J.; Shelley, T. J.; Reyes, J. A.; Hsu, P. C.
2014-05-01
One of the first steps in establishing safe handling procedures for explosives is small-scale safety and thermal (SSST) testing. To better understand the response of improvised materials or homemade explosives (HMEs) to SSST testing, 16 HME materials were compared to three standard military explosives in a proficiency-type round robin study among five laboratories-two DoD and three DOE-sponsored by DHS. The testing matrix has been designed to address problems encountered with improvised materials-powder mixtures, liquid suspensions, partially wetted solids, immiscible liquids, and reactive materials. More than 30 issues have been identified that indicate standard test methods may require modification when applied to HMEs to derive accurate sensitivity assessments needed for developing safe handling and storage practices. This paper presents a generalized comparison of the results among the testing participants, comparison of friction results from BAM (German Bundesanstalt für Materi-alprüfung) and ABL (Allegany Ballistics Laboratory) designed testing equipment, and an overview of the statistical results from the RDX (1,3,5-Trinitroperhydro-1,3,5-triazine) standard tested throughout the proficiency test.
In-flight and laboratory vacuum-friction test results
NASA Technical Reports Server (NTRS)
Devine, E. J.; Evans, H. E.; Leasure, W. A.
1973-01-01
Coefficient of friction measurements were made for six unlubricated metal couples exposed to the space environment aboard the OV-1-13 spacecraft and exposed to laboratory vacuum. Materials studied included mutually soluble, partially soluble, and insoluble metal combinations. Two samples of each material couple were tested in space and in the laboratory using the disk and rider technique. Linear velocity was 0.10 cm/s (2.5 in/min) and rider normal load was 4.45 N (1 lb) for the gold versus silver couples and 8.90 N (2lb) for the other combinations. Results showed that friction data obtained in a clean ion-pumped laboratory vacuum of 10 to the minus 10 power materials with low mutual solubility can be correlated to operation in the vicinity of a typical scientific spacecraft that is exposed to an ambient pressure as low as 10 to the minus 12 power torr. The expected increase in coefficient of friction with solubility was shown. Material couples with high mutual solubility present the hazard of unpredictable drastic friction increase in orbit which may not be evident in laboratory testing at levels down to 10 to the minus 10 power torr. It was also shown that gross cold welding of unlubricated metals exposed to a satellite environment does not occur.
Recommendations for Filler Material Composition and Delivery Method for Bench-Scale Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hardin, Ernest; Brady, Patrick Vane
This report supplements Joint Workplan on Filler Investigations for DPCs (SNL 2017) providing new and some corrected information for use in planning Phase 1 laboratory testing of slurry cements as possible DPC fillers. The scope description is to "Describe a complete laboratory testing program for filler composition, delivery, emplacement in surrogate canisters, and post-test examination. To the extent possible specify filler material and equipment sources." This report includes results from an independent expert review (Dr. Arun Wagh, retired from Argonne National Laboratory and contracted by Sandia) that helped to narrow the range of cement types for consideration, and to providemore » further guidance on mix variations to optimize injectability, durability, and other aspects of filler performance.« less
NASA Technical Reports Server (NTRS)
Stradling, J.; Pippen, D. L.
1985-01-01
The NASA Johnson Space Center White Sands Test Facility (WSTF) performs aerospace materials testing and evaluation. Established in 1963, the facility grew from a NASA site dedicated to the development of space engines for the Apollo project to a major test facility. In addition to propulsion tests, it tests materials and components, aerospace fluids, and metals and alloys in simulated space environments.
46 CFR 160.064-6 - Examinations, tests and inspections.
Code of Federal Regulations, 2010 CFR
2010-10-01
... labeled water safety buoyant devices shall maintain quality control of the materials used, manufacturing... available to the recognized laboratory inspector or to the Coast Guard marine inspector, or both, for review upon request. (b) Laboratory inspections and tests. Such examinations, inspections and tests as are...
Setterbo, Jacob J.; Chau, Anh; Fyhrie, Patricia B.; Hubbard, Mont; Upadhyaya, Shrini K.; Symons, Jennifer E.; Stover, Susan M.
2012-01-01
Background Racetrack surface is a risk factor for racehorse injuries and fatalities. Current research indicates that race surface mechanical properties may be influenced by material composition, moisture content, temperature, and maintenance. Race surface mechanical testing in a controlled laboratory setting would allow for objective evaluation of dynamic properties of surface and factors that affect surface behavior. Objective To develop a method for reconstruction of race surfaces in the laboratory and validate the method by comparison with racetrack measurements of dynamic surface properties. Methods Track-testing device (TTD) impact tests were conducted to simulate equine hoof impact on dirt and synthetic race surfaces; tests were performed both in situ (racetrack) and using laboratory reconstructions of harvested surface materials. Clegg Hammer in situ measurements were used to guide surface reconstruction in the laboratory. Dynamic surface properties were compared between in situ and laboratory settings. Relationships between racetrack TTD and Clegg Hammer measurements were analyzed using stepwise multiple linear regression. Results Most dynamic surface property setting differences (racetrack-laboratory) were small relative to surface material type differences (dirt-synthetic). Clegg Hammer measurements were more strongly correlated with TTD measurements on the synthetic surface than the dirt surface. On the dirt surface, Clegg Hammer decelerations were negatively correlated with TTD forces. Conclusions Laboratory reconstruction of racetrack surfaces guided by Clegg Hammer measurements yielded TTD impact measurements similar to in situ values. The negative correlation between TTD and Clegg Hammer measurements confirms the importance of instrument mass when drawing conclusions from testing results. Lighter impact devices may be less appropriate for assessing dynamic surface properties compared to testing equipment designed to simulate hoof impact (TTD). Potential Relevance Dynamic impact properties of race surfaces can be evaluated in a laboratory setting, allowing for further study of factors affecting surface behavior under controlled conditions. PMID:23227183
NASA Technical Reports Server (NTRS)
Devivar, Rodrigo
2014-01-01
The performance of a material is greatly influenced by its thermal and chemical properties. Analytical pyrolysis, when coupled to a GC-MS system, is a powerful technique that can unlock the thermal and chemical properties of almost any substance and provide vital information. At NASA, we depend on precise thermal analysis instrumentation for understanding aerospace travel. Our analytical techniques allow us to test materials in the laboratory prior to an actual field test; whether the field test is miles up in the sky or miles underground, the properties of any involved material must be fully studied and understood in the laboratory.
Blackwood, Kym S; Burdz, Tamara V; Turenne, Christine Y; Sharma, Meenu K; Kabani, Amin M; Wolfe, Joyce N
2005-01-01
Background In the field of clinical mycobacteriology, Mycobacterium tuberculosis (MTB) can be a difficult organism to manipulate due to the restrictive environment of a containment level 3 (CL3) laboratory. Tests for rapid diagnostic work involving smears and molecular methods do not require CL3 practices after the organism has been rendered non-viable. While it has been assumed that after organism deactivation these techniques can be performed outside of a CL3, no conclusive study has consistently confirmed that the organisms are noninfectious after the theoretical 'deactivation' steps. Previous studies have shown that initial steps (such as heating /chemical fixation) may not consistently kill MTB organisms. Methods An inclusive viability study (n = 226) was undertaken to determine at which point handling of culture extraction materials does not necessitate a CL3 environment. Four different laboratory protocols tested for viability included: standard DNA extractions for IS6110 fingerprinting, crude DNA preparations for PCR by boiling and mechanical lysis, protein extractions, and smear preparations. For each protocol, laboratory staff planted a proportion of the resulting material to Bactec 12B medium that was observed for growth for 8 weeks. Results Of the 208 isolates initially tested, 21 samples grew within the 8-week period. Sixteen (7.7%) of these yielded positive results for MTB that included samples of: deactivated culture resuspensions exposed to 80°C for 20 minutes, smear preparations and protein extractions. Test procedures were consequently modified and tested again (n = 18), resulting in 0% viability. Conclusions This study demonstrates that it cannot be assumed that conventional practices (i.e. smear preparation) or extraction techniques render the organism non-viable. All methodologies, new and existing, should be examined by individual laboratories to validate the safe removal of material derived from MTB to the outside of a CL3 laboratory. This process is vital to establish in house biosafety-validated practices with the aim of protecting laboratory workers conducting these procedures. PMID:15667662
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thompson, D. G.
2002-01-01
A round-robin study was conducted with the participation of three laboratory facilities: Los Alamos National Laboratory (LANL), BWXT Pantex Plant (PX), and Lawrence Livermore National Laboratory (LLNL). The study involved the machining and quasi-static tension testing of two plastic-bonded high explosive (PBX) composites, PBX 9501 and PBX 9502. Nine tensile specimens for each type of PBX were to be machined at each of the three facilities; 3 of these specimens were to be sent to each of the participating materials testing facilities for tensile testing. The resultant data was analyzed to look for trends associated with specimen machining location and/ormore » trends associated with materials testing location. The analysis provides interesting insights into the variability and statistical nature of mechanical properties testing on PBX composites. Caution is warranted when results are compared/exchanged between testing facilities.« less
Statistical Analysis Tools for Learning in Engineering Laboratories.
ERIC Educational Resources Information Center
Maher, Carolyn A.
1990-01-01
Described are engineering programs that have used automated data acquisition systems to implement data collection and analyze experiments. Applications include a biochemical engineering laboratory, heat transfer performance, engineering materials testing, mechanical system reliability, statistical control laboratory, thermo-fluid laboratory, and a…
1983-04-01
1.0 INTRODUCTION AND SCOPE 1 2.0 PROGRESS SUMMARY 3 2.1 Soil Element Model Development 3 2.2 U.S. Any Engineer Waterways Experiment Station (WES...LABORATORY BEHAVIOR OF SAND 8 3.1 Introduction 8 3.2 Material Description 8 3.3 Laboratory Tests Performed 9 3.4 Laboratory Test Results 14 4.0 MODELING THE... INTRODUCTION AND SCOPE The subject of this annual report is constitutive modeling of cohesionless soil, for both laboratory standard static test conditions
Preparation and Use of Polish Mushroom Proficiency Testing Materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Polkowska-Motrenko, Halina
2008-08-14
Mushroom reference materials have been prepared and characterized for the use in proficiency tests according to a procedure established within the frame of an IAEA Interregional Technical Cooperation Project. The materials were used for conducting the proficiency tests in Poland in 2005-2007. The results obtained by participating laboratories are presented and discussed.
Unit: Sticking Together, First Trial Materials, Inspection Set.
ERIC Educational Resources Information Center
Australian Science Education Project, Toorak, Victoria.
These materials, including teacher's guide, student test booklet and laboratory guide, student workbook, test booklet, and a booklet explaining the answers to the questions in the test booklet, are first trial versions of a unit that will form part of the Australian Science Education Project instructional materials for grades seven through ten.…
Automation software for a materials testing laboratory
NASA Technical Reports Server (NTRS)
Mcgaw, Michael A.; Bonacuse, Peter J.
1990-01-01
The software environment in use at the NASA-Lewis Research Center's High Temperature Fatigue and Structures Laboratory is reviewed. This software environment is aimed at supporting the tasks involved in performing materials behavior research. The features and capabilities of the approach to specifying a materials test include static and dynamic control mode switching, enabling multimode test control; dynamic alteration of the control waveform based upon events occurring in the response variables; precise control over the nature of both command waveform generation and data acquisition; and the nesting of waveform/data acquisition strategies so that material history dependencies may be explored. To eliminate repetitive tasks in the coventional research process, a communications network software system is established which provides file interchange and remote console capabilities.
Siddiki, Nayyarzia; Nantung, Tommy; Kim, Daehyeon
2014-01-01
In order to implement MEPDG hierarchical inputs for unbound and subgrade soil, a database containing subgrade M R, index properties, standard proctor, and laboratory M R for 140 undisturbed roadbed soil samples from six different districts in Indiana was created. The M R data were categorized in accordance with the AASHTO soil classifications and divided into several groups. Based on each group, this study develops statistical analysis and evaluation datasets to validate these models. Stress-based regression models were evaluated using a statistical tool (analysis of variance (ANOVA)) and Z-test, and pertinent material constants (k 1, k 2 and k 3) were determined for different soil types. The reasonably good correlations of material constants along with M R with routine soil properties were established. Furthermore, FWD tests were conducted on several Indiana highways in different seasons, and laboratory resilient modulus tests were performed on the subgrade soils that were collected from the falling weight deflectometer (FWD) test sites. A comparison was made of the resilient moduli obtained from the laboratory resilient modulus tests with those from the FWD tests. Correlations between the laboratory resilient modulus and the FWD modulus were developed and are discussed in this paper. PMID:24701162
Development of fire test methods for airplane interior materials
NASA Technical Reports Server (NTRS)
Tustin, E. A.
1978-01-01
Fire tests were conducted in a 737 airplane fuselage at NASA-JSC to characterize jet fuel fires in open steel pans (simulating post-crash fire sources and a ruptured airplane fuselage) and to characterize fires in some common combustibles (simulating in-flight fire sources). Design post-crash and in-flight fire source selections were based on these data. Large panels of airplane interior materials were exposed to closely-controlled large scale heating simulations of the two design fire sources in a Boeing fire test facility utilizing a surplused 707 fuselage section. Small samples of the same airplane materials were tested by several laboratory fire test methods. Large scale and laboratory scale data were examined for correlative factors. Published data for dangerous hazard levels in a fire environment were used as the basis for developing a method to select the most desirable material where trade-offs in heat, smoke and gaseous toxicant evolution must be considered.
This report presents examples of the relationships between the results of laboratory leaching tests, as defined by the Leaching Environmental Assessment Framework (LEAF) or analogous international test methods, and leaching of constituents from a broad range of materials under di...
TRITIUM LABORATORY, TRA666, INTERIOR. MAIN FLOOR. CONTROL ROOM ENCLOSURE AT ...
TRITIUM LABORATORY, TRA-666, INTERIOR. MAIN FLOOR. CONTROL ROOM ENCLOSURE AT CENTER OF VIEW. SIGN ABOVE DOOR SAYS "HYDRAULIC TEST FACILITY CONTROL ROOM." SIGN IN WINDOW SAYS "EATING AREA." "EVACUATION AND EMERGENCY INFORMATION" IS POSTED ON CABINET AT LEFT OF VIEW. INL NEGATIVE NO. HD30-2-3. Mike Crane, Photographer, 6/2001 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Residue analysis of tetracyclines in poultry muscle: shortcomings revealed by a proficiency test.
Berendsen, B J A; Van Rhijn, J A
2006-11-01
A proficiency test for tetracycline drug residues in poultry muscle was organized according to the guidelines of International Laboratory Accreditation Cooperation (ILAC) ILAC-G13:2000 (2000). For the proficiency test, three test materials were prepared. The homogeneity and stability of the materials during the study were demonstrated. Sixteen laboratories accepted the invitation to participate in the proficiency test; 11 laboratories reported results within the time frame of the study. Most notably, only four of the participating laboratories complied with the definition of the maximum residue limit (MRL) concerning the inclusion of 4-epimers as stated in European Commission Regulation 281/96 (1996). Most participants reported values for the decision limit (CCalpha) and detection capability (CCbeta) and hence were already in compliance with European Commission 2002/657/EC (2002) for this aspect of method validation. However, some CCalpha and CCbeta values were not in agreement with the actual within-laboratory reproducibility calculated from the results reported in this proficiency test. Although most laboratories obtained satisfactory results, it is clear that an effort is needed to include 4-epiOTC, 4-epiTC and 4-epiCTC in the analytical methods. Moreover, reconsideration of values determined for CCalpha and CCbeta with respect to their accuracy may be necessary in some cases.
NASA Technical Reports Server (NTRS)
Hirsch, David
2009-01-01
Spacecraft fire safety emphasizes fire prevention, which is achieved primarily through the use of fire-resistant materials. Materials selection for spacecraft is based on conventional flammability acceptance tests, along with prescribed quantity limitations and configuration control for items that are non-pass or questionable. ISO 14624-1 and -2 are the major methods used to evaluate flammability of polymeric materials intended for use in the habitable environments of spacecraft. The methods are upward flame-propagation tests initiated in static environments and using a well-defined igniter flame at the bottom of the sample. The tests are conducted in the most severe flaming combustion environment expected in the spacecraft. The pass/fail test logic of ISO 14624-1 and -2 does not allow a quantitative comparison with reduced gravity or microgravity test results; therefore their use is limited, and possibilities for in-depth theoretical analyses and realistic estimates of spacecraft fire extinguishment requirements are practically eliminated. To better understand the applicability of laboratory test data to actual spacecraft environments, a modified ISO 14624 protocol has been proposed that, as an alternative to qualifying materials as pass/fail in the worst-expected environments, measures the actual upward flammability limit for the material. A working group established by NASA to provide recommendations for exploration spacecraft internal atmospheres realized the importance of correlating laboratory data with real-life environments and recommended NASA to develop a flammability threshold test method. The working group indicated that for the Constellation Program, the flammability threshold information will allow NASA to identify materials with increased flammability risk from oxygen concentration and total pressure changes, minimize potential impacts, and allow for development of sound requirements for new spacecraft and extravehicular landers and habitats. Furthermore, recent research has shown that current normal gravity materials flammability tests do not correlate with flammability in ventilated, micro- or reduced-gravity conditions. Currently, the materials selection for spacecraft is based on the assumption of commonality between ground flammability test results and spacecraft environments, which does not appear to be valid. Materials flammability threshold data acquired in normal gravity can be correlated with data obtained in microgravity or reduced-gravity experiments, and consequently a more accurate assessment of the margin of safety of the material in the real environment can be made. In addition, the method allows the option of selecting better or best space system materials, as opposed to what would be considered just acceptable from a flammability point of view and realistic assessment of spacecraft fire extinguishment needs, which could result in significant weight savings. The knowledge afforded by this technique allows for limited extrapolations of flammability behavior to conditions not specifically tested and that could potentially result in significant cost and time savings. The intent of this Technical Specification is to bring to the attention of International Aerospace Community the importance of correlating laboratory test data with real-life space systems applications. The method presented is just one of the possibilities that are believed will lead to better understanding the applicability of laboratory aerospace materials flammability test data. International feedback on improving the proposed method, as well as suggestions for correlating other laboratory aerospace test data with real-life applications relevant to space systems are being sought.
Certification Tests on Cold Patch Asphalt Repair Materials for Use in Airfield Pavements
2010-06-01
in Airfield Pavements Mariely Mejías-Santiago, Franciso del Valle Roldán, and Lucy P. Priddy Geotechnical and Structures Laboratory U.S. Army...28 Figure 19. Pavement structure in the test section...ERDC), Geotechnical and Structures Laboratory (GSL), Vicksburg, MS. The findings and recommendations presented in this report are based upon laboratory
Offgassing Characterization of the Columbus Laboratory Module
NASA Technical Reports Server (NTRS)
Rampini, riccardo; Lobascio, Cesare; Perry, Jay L.; Hinderer, Stephan
2005-01-01
Trace gaseous contamination in the cabin environment is a major concern for manned spacecraft, especially those designed for long duration missions, such as the International Space Station (ISS). During the design phase, predicting the European-built Columbus laboratory module s contribution to the ISS s overall trace contaminant load relied on "trace gas budgeting" based on material level and assembled article tests data. In support of the Qualification Review, a final offgassing test has been performed on the complete Columbus module to gain cumulative system offgassing data. Comparison between the results of the predicted offgassing load based on the budgeted material/assembled article-level offgassing rates and the module-level offgassing test is presented. The Columbus module offgassing test results are also compared to results from similar tests conducted for Node 1, U.S. Laboratory, and Airlock modules.
Zhang, M.; Takahashi, M.; Morin, R.H.; Endo, H.; Esaki, T.; ,
2002-01-01
The accurate hydraulic characterization of low-permeability subsurface environments has important practical significance. In order to examine this issue from the perspective of laboratory-based approaches, we review some recent advancements in the theoretical analyses of three different laboratory techniques specifically applied to low-permeability geologic materials: constant-head, constant flow-rate and transient-pulse permeability tests. Some potential strategies for effectively decreasing the time required to confidently estimate the permeability of these materials are presented. In addition, a new and versatile laboratory system is introduced that can implement any of these three test methods while simultaneously subjecting a specimen to high confining pressures and pore pressures, thereby simulating in situ conditions at great depths. The capabilities and advantages of this innovative system are demonstrated using experimental data derived from Shirahama sandstone and Inada granite, two rock types widely encountered in Japan.
Screening for Saponins Using the Blood Hemolysis Test. An Undergraduate Laboratory Experiment.
ERIC Educational Resources Information Center
Sotheeswaran, Subramaniam
1988-01-01
Describes an experiment for undergraduate chemistry laboratories involving a chemical found in plants and some sea animals. Discusses collection and identification of material, a hemolysis test, preparation of blood-coated agar plates, and application of samples. (CW)
Heintze, Siegward D
2007-01-01
An accepted principle in restorative dentistry states that restorations should be placed with the best marginal quality possible to avoid postoperative sensitivity, marginal discoloration, and secondary caries. Different laboratory methods claim to predict the clinical performance of restorative materials, for example, tests of bond strength and microleakage and gap analysis. The purpose of this review was twofold: (1) find studies that correlated the results of bond strength tests with either microleakage or gap analysis for the same materials, and (2) find studies that correlated the results of microleakage and/or gaps with the clinical parameters for the same materials. Furthermore, influencing factors on the results of the laboratory tests were reviewed and assessed. For the first question, searches for studies were conducted in the MEDLINE database and IADR/AADR abtracts online with specific search and inclusion criteria. The outcome for each study was assessed on the basis of the statistical test applied in the study, and finally the number of studies with or without correlation was compiled. For the second question, results of the quantitative marginal analysis of Class V restorations published by the University of Zürich with the same test protocol and prospective clinical trials were searched that investigated the same materials for at least 2 years in Class V cavities. Pearson correlation coefficients were calculated for pooled data of materials and clinical outcome parameters such as retention loss, marginal discoloration, marginal integrity, and secondary caries. For the correlation of dye penetration and clinical outcome, studies on Class V restorations published by the same research institute were searched in MEDLINE that examined the same adhesive systems as the selected clinical trials. For the correlation bond strength/microleakage, 30 studies were included into the review, and for the correlation bond strength/gap analysis 18 studies. For both topics, about 80% of the studies revealed that there was no correlation between the two methods. For the correlation quantitative marginal analysis/clinical outcome, data were compared to the clinical outcome of 11 selected clinical studies. In only 2 out of the 11 studies (18%) did the clinical outcome match the prognosis based on the laboratory tests; the remaining studies did not show any correlation. When pooling data on 20 adhesive systems, no correlation was found between the percentage of continuous margin of restorations placed in extracted premolars and the percentage of teeth that showed no retention loss in clinical studies, no discoloured margins, acceptable margins, or absence of secondary caries. With regard to the correlation of dye penetration and clinical studies, no sufficient number of studies was found that matched the inclusion criteria. However, literature data suggest that there is no correlation between microleakage data as measured in the laboratory and clinical parameters. The results of bond strength tests did not correlate with laboratory tests that evaluated the marginal seal of restorations such as microleakage or gap analysis. The quantitative marginal analysis of Class V fillings in the laboratory was unable to predict the performance of the same materials in vivo. Therefore, microleakage tests or the quantitative marginal analysis should be abandoned and research should focus on laboratory tests that are validated with regard to their ability to satisfactorily predict the clinical performance of restorative materials.
Inoculation testing of Apollo 12 materials
NASA Technical Reports Server (NTRS)
1969-01-01
E. Landrum Young, Brown and Root Northrop, injects a young Japanese quail with a suspension of pulvarized Apollo 12 lunar material within a quarantine cabinet in the Invertebrate, Aves and Fish Laboratory of the Lunar Receiving Laboratory, bldg 37, Manned Spacecraft Center. The bird is being inoculated in the abdominal cavity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
K. L. Davis; D. L. Knudson; J. L. Rempe
New materials are being considered for fuel, cladding, and structures in next generation and existing nuclear reactors. Such materials can undergo significant dimensional and physical changes during high temperature irradiations. In order to accurately predict these changes, real-time data must be obtained under prototypic irradiation conditions for model development and validation. To provide such data, researchers at the Idaho National Laboratory (INL) High Temperature Test Laboratory (HTTL) are developing several instrumented test rigs to obtain data real-time from specimens irradiated in well-controlled pressurized water reactor (PWR) coolant conditions in the Advanced Test Reactor (ATR). This paper reports the status ofmore » INL efforts to develop and evaluate prototype test rigs that rely on Linear Variable Differential Transformers (LVDTs) in laboratory settings. Although similar LVDT-based test rigs have been deployed in lower flux Materials Testing Reactors (MTRs), this effort is unique because it relies on robust LVDTs that can withstand higher temperatures and higher fluxes than often found in other MTR irradiations. Specifically, the test rigs are designed for detecting changes in length and diameter of specimens irradiated in ATR PWR loops. Once implemented, these test rigs will provide ATR users with unique capabilities that are sorely needed to obtain measurements such as elongation caused by thermal expansion and/or creep loading and diameter changes associated with fuel and cladding swelling, pellet-clad interaction, and crud buildup.« less
Safety validation test equipment operation
NASA Astrophysics Data System (ADS)
Kurosaki, Tadaaki; Watanabe, Takashi
1992-08-01
An overview of the activities conducted on safety validation test equipment operation for materials used for NASA manned missions is presented. Safety validation tests, such as flammability, odor, offgassing, and so forth were conducted in accordance with NASA-NHB-8060.1C using test subjects common with those used by NASA, and the equipment used were qualified for their functions and performances in accordance with NASDA-CR-99124 'Safety Validation Test Qualification Procedures.' Test procedure systems were established by preparing 'Common Procedures for Safety Validation Test' as well as test procedures for flammability, offgassing, and odor tests. The test operation organization chaired by the General Manager of the Parts and Material Laboratory of NASDA (National Space Development Agency of Japan) was established, and the test leaders and operators in the organization were qualified in accordance with the specified procedures. One-hundred-one tests had been conducted so far by the Parts and Material Laboratory according to the request submitted by the manufacturers through the Space Station Group and the Safety and Product Assurance for Manned Systems Office.
NASA Astrophysics Data System (ADS)
Jannati, E. D.; Setiawan, A.; Siahaan, P.; Rochman, C.
2018-05-01
This study aims to determine the description of virtual laboratory learning media development to improve science literacy skills of Mechanical Engineering students on the concept of basic Physics. Quasi experimental method was employed in this research. The participants of this research were first semester students of mechanical engineering in Majalengka University. The research instrument was readability test of instructional media. The results of virtual laboratory learning media readability test show that the average score is 78.5%. It indicates that virtual laboratory learning media development are feasible to be used in improving science literacy skill of Mechanical Engineering students in Majalengka University, specifically on basic Physics concepts of material measurement.
2003-08-21
KENNEDY SPACE CENTER, FLA. - Dr. Paul Hintze (left) explains to Center Director Jim Kennedy a project he is working at the KSC Beach Corrosion Test Site. Hitze is doing post-graduate work for the National Research Council. The test facility site was established in the 1960s and has provided more than 30 years of historical information on the long-term performance of many materials in use at KSC and other locations around the world. Located 100 feet from the Atlantic Ocean approximately 1 mile south of the Space Shuttle launch sites, the test facility includes an atmospheric exposure site, a flowing seawater exposure site, and an on-site electrochemistry laboratory and monitoring station. The beach laboratory is used to conduct real-time corrosion experiments and provides for the remote monitoring of surrounding weather conditions. The newly added flowing seawater immersion facility provides for the immersion testing of materials and devices under controlled conditions.
Laboratory and field evaluation of hot mix asphalt with high contents of reclaimed asphalt pavement
NASA Astrophysics Data System (ADS)
Van Winkle, Clinton Isaac
Currently in Iowa, the amount of RAP materials allowed for the surface layer is limited to 15% by weight. The objective of this project was to develop quality standards for inclusion of RAP content higher than 15% in asphalt mixtures. To meet Superpave mix design requirements, it was necessary to fractionate the RAP materials. Based on the extensive sieve-by-sieve analysis of RAP materials, the optimum sieve size to fractionate RAP materials was identified. To determine if the higher percentage of RAP materials than 15% can be used in Iowa's state highway, three test sections with 30.0%, 35.5% and 39.2% of RAP materials were constructed on Highway 6 in Iowa City. The construction of the field test sections was monitored and the cores were obtained to measure field densities of test sections. Field mixtures collected from test sections were compacted in the laboratory in order to test the moisture sensitivity using a Hamburg Wheel Tracking Device. The binder was extracted from the field mixtures with varying amounts of RAP materials and tested to determine the effects of RAP materials on the PG grade of a virgin binder. Field cores were taken from the various mix designs to determine the percent density of each test section. A condition survey of the test sections was then performed to evaluate the short-term performance.
RODENT RESISTANT CABLE MATERIALS.
Several formulations of organotin compounds in polymeric materials were evaluated for application to polyethylene cable coatings. Tributyltin ...test the effectiveness of this formulation in protecting treated WF-16 cable from rodent damage. In a laboratory test vapors of tributyltin chloride
Impacts: NIST Building and Fire Research Laboratory (technical and societal)
NASA Astrophysics Data System (ADS)
Raufaste, N. J.
1993-08-01
The Building and Fire Research Laboratory (BFRL) of the National Institute of Standards and Technology (NIST) is dedicated to the life cycle quality of constructed facilities. The report describes major effects of BFRL's program on building and fire research. Contents of the document include: structural reliability; nondestructive testing of concrete; structural failure investigations; seismic design and construction standards; rehabilitation codes and standards; alternative refrigerants research; HVAC simulation models; thermal insulation; residential equipment energy efficiency; residential plumbing standards; computer image evaluation of building materials; corrosion-protection for reinforcing steel; prediction of the service lives of building materials; quality of construction materials laboratory testing; roofing standards; simulating fires with computers; fire safety evaluation system; fire investigations; soot formation and evolution; cone calorimeter development; smoke detector standards; standard for the flammability of children's sleepwear; smoldering insulation fires; wood heating safety research; in-place testing of concrete; communication protocols for building automation and control systems; computer simulation of the properties of concrete and other porous materials; cigarette-induced furniture fires; carbon monoxide formation in enclosure fires; halon alternative fire extinguishing agents; turbulent mixing research; materials fire research; furniture flammability testing; standard for the cigarette ignition resistance of mattresses; support of navy firefighter trainer program; and using fire to clean up oil spills.
ERIC Educational Resources Information Center
Ohio State Univ., Columbus. National Center for Research in Vocational Education.
This instructional package on material testing and quality control of soils has been adapted from military curriculum materials for use in technical and vocational education programs. This short course presents basic information on soils as well as exploration, field identification, and laboratory procedures that will enable students completing…
Materials and Nondestructive Evaluation Laboratoriers: User Test Planning Guide
NASA Technical Reports Server (NTRS)
Schaschl, Leslie
2011-01-01
The Materials and Nondestructive Evaluation Laboratory process, milestones and inputs are unknowns to first-time users. The Materials and Nondestructive Evaluation Laboratory Planning Guide aids in establishing expectations for both NASA and non- NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware developers. It is intended to assist their project engineering personnel in materials analysis planning and execution. Material covered includes a roadmap of the analysis process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, products, and inputs necessary to define scope of analysis, cost, and schedule are included as an appendix to the guide.
Burner Rig in the Material and Stresses Building
1969-11-21
A burner rig heats up a material sample in the Materials and Stresses Building at the National Aeronautics and Space Administration (NASA) Lewis Research Center. Materials technology is an important element in the successful development of advanced airbreathing and rocket propulsion systems. Different types of engines operate in different environments so an array of dependable materials is needed. NASA Lewis began investigating the characteristics of different materials shortly after World War II. In 1949 the materials group was expanded into its own division. The Lewis researchers sought to study and test materials in environments that simulate the environment in which they would operate. The Materials and Stresses Building, built in 1949, contained a number of laboratories to analyze the materials. They are subjected to high temperatures, high stresses, corrosion, irradiation, and hot gasses. The Physics of Solids Laboratory included a cyclotron, cloud chamber, helium cryostat, and metallurgy cave. The Metallographic Laboratory possessed six x-ray diffraction machines, two metalloscopes, and other equipment. The Furnace Room had two large induction machines, a 4500⁰ F graphite furnace, and heat treating equipment. The Powder Laboratory included 60-ton and 3000-ton presses. The Stresses Laboratory included stress rupture machines, fatigue machines, and tensile strength machines.
UHPC for Blast and Ballistic Protection, Explosion Testing and Composition Optimization
NASA Astrophysics Data System (ADS)
Bibora, P.; Drdlová, M.; Prachař, V.; Sviták, O.
2017-10-01
The realization of high performance concrete resistant to detonation is the aim and expected outcome of the presented project, which is oriented to development of construction materials for larger objects as protective walls and bunkers. Use of high-strength concrete (HSC / HPC - “high strength / performance concrete”) and high-fiber reinforced concrete (UHPC / UHPFC -“Ultra High Performance Fiber Reinforced Concrete”) seems to be optimal for this purpose of research. The paper describes the research phase of the project, in which we focused on the selection of specific raw materials and chemical additives, including determining the most suitable type and amount of distributed fiber reinforcement. Composition of UHPC was optimized during laboratory manufacture of test specimens to obtain the best desired physical- mechanical properties of developed high performance concretes. In connection with laboratory testing, explosion field tests of UHPC specimens were performed and explosion resistance of laboratory produced UHPC testing boards was investigated.
77 FR 41188 - Clinical Laboratory Improvement Advisory Committee (CLIAC)
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-12
... technological advances, such as new test methods and the electronic transmission of laboratory information... potential need for educational materials and resources for sites that test under a Provider-performed Microscopy Certificate; and the increased use of culture-independent microbiology diagnostics and the impact...
Integrated Data Collection Analysis (IDCA) Program - Final Review September 12, 2012 at DHS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandstrom, Mary M.; Brown, Geoffrey W.; Warner, Kirstin F.
The Integrated Data Collection Analysis (IDCA) program conducted a final program review at the Department of Homeland Security on September 12, 2012. The review was focused on the results of the program over the complete performance period. A summary presentation delineating the accomplished tasks started the meeting, followed by technical presentations on various issues that arose during the performance period. The presentations were completed with a statistical evaluation of the testing results from all the participants in the IDCA Proficiency Test study. The meeting closed with a discussion of potential sources of funding for continuing work to resolve some ofmore » these technical issues. This effort, funded by the Department of Homeland Security (DHS), put the issues of safe handling of these materials in perspective with standard military explosives. The study added Small-Scale Safety and Thermal (SSST) testing results for a broad suite of different HMEs to the literature, and suggested new guidelines and methods to develop safe handling practices for HMEs. Each participating testing laboratory used identical test materials and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. The results were compared among the laboratories and then compared to historical data from various sources. The testing performers involved were Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Naval Surface Warfare Center, Indian Head Division (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory, Tyndall AFB (AFRL/RXQL). These tests were conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.« less
Modeling for Military Operational Medicine Scientific and Technical Objectives
2004-09-01
placed directly under armor ; and (3) new material that matches the human tissue better. 5 Figure 1. Schematic of the newer version of ATM 2.1.1 Laboratory...sensor units are placed directly under armor ; and (3) new material that matches the human tissue better. 2. We conducted a series of laboratory test
Upward Flame Propagation and Wire Insulation Flammability: 2006 Round Robin Data Analysis
NASA Technical Reports Server (NTRS)
Hirsch, David B.
2007-01-01
This viewgraph document reviews test results from tests of different material used for wire insulation for flame propagation and flammability. The presentation focused on investigating data variability both within and between laboratories; evaluated the between-laboratory consistency through consistency statistic h, which indicates how one laboratory s cell average compares with averages from other labs; evaluated the within-laboratory consistency through the consistency statistic k, which is an indicator of how one laboratory s within-laboratory variability compares with the variability of other labs combined; and extreme results were tested to determine whether they resulted by chance or from nonrandom causes (human error, instrument calibration shift, non-adherence to procedures, etc.)
Chemical Vapor Deposition of Multispectral Domes
1975-04-01
optical testing, was also cut out as indicated in Figure 10. The image spoiling measureinents were performed at the Air Force Avionics Laboratory on...AD-A014 362 CHEMICAL VAPOR DEPOSITION OF MULTISPECTRAL DOMES B. A. diBenedetto, et al Raytheon Company Prepared for: Air Force Materials Laboratory...Approved for public release; distribution unlimited. ) F) .• •~~EP 7 ’+ i.i AIR FORCE MATERIALS LABORATORY AIR FORCE SYSTEMS COMMAND WRIGHT-PATrERSON AIR
MTR WING, TRA604. A LABORATORY ROOM WITH ITS CABINETS AND ...
MTR WING, TRA-604. A LABORATORY ROOM WITH ITS CABINETS AND SERVICE STRIP DOWN CENTER OF ROOM. CARD IN LEFT CORNER OF VIEW WAS INSERTED BY INL PHOTOGRAPHER TO COVER AN OBSOLETE SECURITY RESTRICTION PRINTED ON THE ORIGINAL NEGATIVE. INL NEGATIVE NO. 3817. Unknown Photographer, 11/28/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Handbook of photothermal test data on encapsulant materials
NASA Astrophysics Data System (ADS)
Liang, R. H.; Oda, K. L.; Chung, S. Y.; Smith, M. V.; Gupta, A.
1983-05-01
Laboratory tests performed to characterize candidate encapsulation materials with respect to changes in their physical and chemical properties caused by photothermal aging are described. Several key material properties relating directly to material degradation and deterioration of performance were identified and were monitored as functions of aging conditions and time. A status report on accelerated testing activities is provided and experimental data are presented. It will be updated periodically as more data become available.
Handbook of photothermal test data on encapsulant materials
NASA Technical Reports Server (NTRS)
Liang, R. H.; Oda, K. L.; Chung, S. Y.; Smith, M. V.; Gupta, A.
1983-01-01
Laboratory tests performed to characterize candidate encapsulation materials with respect to changes in their physical and chemical properties caused by photothermal aging are described. Several key material properties relating directly to material degradation and deterioration of performance were identified and were monitored as functions of aging conditions and time. A status report on accelerated testing activities is provided and experimental data are presented. It will be updated periodically as more data become available.
Peters, Brenton C; Fitzgerald, Christopher J
2006-10-01
Laboratory and field data reported in the literature are confusing with regard to "adequate" protection thresholds for borate timber preservatives. The confusion is compounded by differences in termite species, timber species and test methodology. Laboratory data indicate a borate retention of 0.5% mass/mass (m/m) boric acid equivalent (BAE) would cause > 90% termite mortality and restrict mass loss in test specimens to < or = 5%. Field data generally suggest that borate retentions appreciably > 0.5% m/m BAE are required. We report two field experiments with varying amounts of untreated feeder material in which Coptotermes acinaciformis (Froggatt) (Isoptera: Rhinotermitidae) responses to borate-treated radiata (Monterey) pine, Pinus radiata D. Don, were measured. The apparently conflicting results between laboratory and field data are explained by the presence or absence of untreated feeder material in the test environment. In the absence of untreated feeder material, wood containing 0.5% BAE provided adequate protection from Coptotermes sp., whereas in the presence of untreated feeder material, increased retentions were required. Furthermore, the retentions required increased with increased amounts of susceptible material present. Some termites, Nasutitermes sp. and Mastotermes darwiniensis Froggatt, for example, are borate-tolerant and borate timber preservatives are not a viable management option with these species. The lack of uniform standards for termite test methodology and assessment criteria for efficacy across the world is recognized as a difficulty with research into the performance of timber preservatives with termites. The many variables in laboratory and field assays make "prescriptive" standards difficult to recommend. The use of "performance" standards to define efficacy criteria ("adequate" protection) is discussed.
Harmonization in laboratory medicine: Requests, samples, measurements and reports.
Plebani, Mario
2016-01-01
In laboratory medicine, the terms "standardization" and "harmonization" are frequently used interchangeably as the final goal is the same: the equivalence of measurement results among different routine measurement procedures over time and space according to defined analytical and clinical quality specifications. However, the terms define two distinct, albeit closely linked, concepts based on traceability principles. The word "standardization" is used when results for a measurement are equivalent and traceable to the International System of Units (SI) through a high-order primary reference material and/or a reference measurement procedure (RMP). "Harmonization" is generally used when results are equivalent, but neither a high-order primary reference material nor a reference measurement procedure is available. Harmonization is a fundamental aspect of quality in laboratory medicine as its ultimate goal is to improve patient outcomes through the provision of accurate and actionable laboratory information. Patients, clinicians and other healthcare professionals assume that clinical laboratory tests performed by different laboratories at different times on the same sample and specimen can be compared, and that results can be reliably and consistently interpreted. Unfortunately, this is not necessarily the case, because many laboratory test results are still highly variable and poorly standardized and harmonized. Although the initial focus was mainly on harmonizing and standardizing analytical processes and methods, the scope of harmonization now also includes all other aspects of the total testing process (TTP), such as terminology and units, report formats, reference intervals and decision limits as well as tests and test profiles, requests and criteria for interpretation. Several projects and initiatives aiming to improve standardization and harmonization in the testing process are now underway. Laboratory professionals should therefore step up their efforts to provide interchangeable and comparable laboratory information in order to ultimately assure better diagnosis and treatment in patient care.
Toxicity of Uranium Adsorbent Materials using the Microtox Toxicity Test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, Jiyeon; Jeters, Robert T.; Gill, Gary A.
2015-10-01
The Marine Sciences Laboratory at the Pacific Northwest National Laboratory evaluated the toxicity of a diverse range of natural and synthetic materials used to extract uranium from seawater. The uranium adsorbent materials are being developed as part of the U. S. Department of Energy, Office of Nuclear Energy, Fuel Resources Program. The goal of this effort was to identify whether deployment of a farm of these materials into the marine environment would have any toxic effects on marine organisms.
NASA Technical Reports Server (NTRS)
Jackson, Dionne
2005-01-01
The NASA Materials Science Laboratory (MSL) provides science and engineering services to NASA and Contractor customers at KSC, including those working for the Space Shuttle. International Space Station. and Launch Services Programs. These services include: (1) Independent/unbiased failure analysis (2) Support to Accident/Mishap Investigation Boards (3) Materials testing and evaluation (4) Materials and Processes (M&P) engineering consultation (5) Metrology (6) Chemical analysis (including ID of unknown materials) (7) Mechanical design and fabrication We provide unique solutions to unusual and urgent problems associated with aerospace flight hardware, ground support equipment and related facilities.
Radioactive Material Used In Research | RadTown USA | US ...
2018-05-01
Some laboratories use radioactive material to assist their research. Radioactive materials are used in research settings to help researchers create and test new medicines, technologies and procedures for plants, animals and people.
Ecological Validity of the Testing Effect: The Use of Daily Quizzes in Introductory Psychology
ERIC Educational Resources Information Center
Batsell, W. Robert, Jr.; Perry, Jennifer L.; Hanley, Elizabeth; Hostetter, Autumn B.
2017-01-01
The testing effect is the enhanced retention of learned information by individuals who have studied and completed a test over the material relative to individuals who have only studied the material. Although numerous laboratory studies and simulated classroom studies have provided evidence of the testing effect, data from a natural class setting…
Bioterrorism: a Laboratory Who Does It?
Lee, Philip A.; Rowlinson, Marie-Claire
2014-01-01
In October 2001, the first disseminated biological warfare attack was perpetrated on American soil. Initially, a few clinical microbiology laboratories were testing specimens from acutely ill patients and also being asked to test nasal swabs from the potentially exposed. Soon after, a significant number of clinical microbiology and public health laboratories received similar requests to test the worried well or evaluate potentially contaminated mail or environmental materials, sometimes from their own break rooms. The role of the clinical and public health microbiology laboratory in response to a select agent event or act of bioterrorism is reviewed. PMID:24648550
Integrated Data Collection Analysis (IDCA) Program - SSST Testing Methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.
The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the methods used for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis during the IDCA program. These methods changed throughout the Proficiency Test and the reasons for these changes are documented in this report. The most significant modifications in standard testing methods are: 1) including one specified sandpaper in impact testing among all the participants, 2) diversifying liquid test methods for selected participants, and 3) including sealed sample holders for thermal testingmore » by at least one participant. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study will suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.« less
A laboratory silicone for preclinical training in ear prosthesis.
Anand, Vijay; Haribabu; Vimala; Gnanasamband, Vimala
2013-07-01
This article describes an industrial elastic silicone as a material for the laboratory fabrication of ear prosthesis. It has been tested for toxicity in lab animals by the SGS India Pvt. Ltd and approved as a material to pass the parameter of abnormal toxicity. This material therefore can be safely recommended for laboratory exercise to fabricate facial prosthesis. The high cost of the maxillo facial silicone materials prohibits their use for facial prosthesis in pre-clinical training of post-graduate students in maxillofacial prosthodontics. For this reason, pre-clinical laboratory exercise in facial prosthesis is inadequate. A few institutions use polymethyl methacrylate resins which are rigid and do not have elastic characteristics of silicone, which is used for facial defects. This cost-effective industrial silicone material which mimics the elastic and color characteristics of the conventional silicones can be recommended for preclinical exercises.
Interlaboratory study of a method for determining nonvolatile organic carbon in aquifer materials
Caughey, M.E.; Barcelona, M.J.; Powell, R.M.; Cahill, R.A.; Gron, C.; Lawrenz, D.; Meschi, P.L.
1995-01-01
The organic carbon fraction in aquifer materials exerts a major influence on the subsurface mobilities of organic and organic-associated contaminants. The spatial distribution of total organic carbon (TOC) in aquifer materials must be determined before the transport of hydrophobic organic pollutants in aquifers can be modeled accurately. Previous interlaboratory studies showed that it is difficult to measure TOC concentrations 1%. We have tested a new analytical method designed to improve the accuracy and precision of nonvolatile TOC quantitation in geologic materials that also contain carbonate minerals. Four authentic aquifer materials and one NIST standard reference material were selected as test materials for a blind collaborative study. Nonvolatile TOC in these materials ranged from 0.05 to 1.4%, while TIC ranged from 0.46 to 12.6%. Sample replicates were digested with sulfurous acid, dried at 40??C, and then combusted at 950??C using LECO or UIC instruments. For the three test materials that contained >2% TIC, incomplete acidification resulted in a systematic positive bias of TOC values reported by five of the six laboratories that used the test method. Participants did not have enough time to become proficient with the new method before they analyzed the test materials. A seventh laboratory successfully used an alternative method that analyzed separate liquid and solid fractions of the acidified sample residues. ?? 1995 Springer-Verlag.
Testing Plastic Deformations of Materials in the Introductory Undergraduate Mechanics Laboratory
ERIC Educational Resources Information Center
Romo-Kroger, C. M.
2012-01-01
Normally, a mechanics laboratory at the undergraduate level includes an experiment to verify compliance with Hooke's law in materials, such as a steel spring and an elastic rubber band. Stress-strain curves are found for these elements. Compression in elastic bands is practically impossible to achieve due to flaccidity. A typical experiment for…
42 CFR 493.1269 - Standard: Hematology.
Code of Federal Regulations, 2011 CFR
2011-10-01
... materials must be tested in duplicate. (b) For all nonmanual coagulation test systems, the laboratory must...) For manual coagulation tests— (1) Each individual performing tests must test two levels of control...
42 CFR 493.1269 - Standard: Hematology.
Code of Federal Regulations, 2010 CFR
2010-10-01
... materials must be tested in duplicate. (b) For all nonmanual coagulation test systems, the laboratory must...) For manual coagulation tests— (1) Each individual performing tests must test two levels of control...
42 CFR 493.1269 - Standard: Hematology.
Code of Federal Regulations, 2014 CFR
2014-10-01
... materials must be tested in duplicate. (b) For all nonmanual coagulation test systems, the laboratory must...) For manual coagulation tests— (1) Each individual performing tests must test two levels of control...
42 CFR 493.1269 - Standard: Hematology.
Code of Federal Regulations, 2012 CFR
2012-10-01
... materials must be tested in duplicate. (b) For all nonmanual coagulation test systems, the laboratory must...) For manual coagulation tests— (1) Each individual performing tests must test two levels of control...
42 CFR 493.1269 - Standard: Hematology.
Code of Federal Regulations, 2013 CFR
2013-10-01
... materials must be tested in duplicate. (b) For all nonmanual coagulation test systems, the laboratory must...) For manual coagulation tests— (1) Each individual performing tests must test two levels of control...
Comparison of Refractory Performance in Black Liquor Gasifiers and a Smelt Test System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peascoe, RA
2001-09-25
Prior laboratory corrosion studies along with experience at the black liquor gasifier in New Bern, North Carolina, clearly demonstrate that serious material problems exist with the gasifier's refractory lining. Mullite-based and alumina-based refractories used at the New Bern facility suffered significant degradation even though they reportedly performed adequately in smaller scale systems. Oak Ridge National Laboratory's involvement in the failure analysis, and the initial exploration of suitable replacement materials, led to the realization that a simple and reliable, complementary method for refractory screening was needed. The development of a laboratory test system and its suitability for simulating the environment ofmore » black liquor gasifiers was undertaken. Identification and characterization of corrosion products were used to evaluate the test system as a rapid screening tool for refractory performance and as a predictor of refractory lifetime. Results from the test systems and pl ants were qualitatively similar.« less
2010-06-07
the materials properties of silicon carbide plates”, S. Kenderian et al., 2009 SPIE Proceedings, vol. 7425 • Materials – 10” x 16” SiC plates...CONFERENCE PROCEEDING 3. DATES COVERED (From - To) 2008-2010 4. TITLE AND SUBTITLE Results from Mechanical Testing of Silicon Carbide for Space...for silicon carbide optical systems that covers material verification through system development. Recent laboratory results for testing of materials
Juhel-Gaugain, Murielle; Fourmond, Marie-Pierre; Delepine, Bernard; Laurentie, Michel; Brigitte, Roudaut; Sanders, Pascal
2005-03-01
Two interlaboratory studies were organized in 2002-2003 in order to check the proficiency of laboratories in confirming the presence of sulfonamide residues in muscle and milk. These studies involved 25 EU National Reference Laboratories (NRLs) from 21 different European Countries in charge of statutory monitoring of antimicrobial residues in food of animal origin at a national level. The study was conducted according to international and national guidelines by the Community Reference Laboratory (CRL) in charge of antimicrobial substances. Four different test matrices of sheep muscle and four different test matrices of bovine milk containing different sulfonamide substances were prepared and sent to the participants. Each participant was asked to use his own routine confirmatory method and to analyse each sample in triplicate within a period of about six weeks during which the stability of the materials was checked by the organizer. The sulfonamide content of each material was determined by calculating the robust means of all the results and the deviation of the results from the assigned values was assessed by calculating Z-scores. Overall, results were satisfactory, particularly considering that it was the first proficiency test dealing with sulfonamides organised by the Community Reference Laboratory.
2003-08-21
KENNEDY SPACE CENTER, FLA. - Louis MacDowell (right), Testbed manager, explains to Center Director Jim Kennedy the use of astmospheric calibration specimens. Placed at various locations, they can rank the corrosivity of the given environment. The KSC Beach Corrosion Test Site was established in the 1960s and has provided more than 30 years of historical information on the long-term performance of many materials in use at KSC and other locations around the world. Located 100 feet from the Atlantic Ocean approximately 1 mile south of the Space Shuttle launch sites, the test facility includes an atmospheric exposure site, a flowing seawater exposure site, and an on-site electrochemistry laboratory and monitoring station. The beach laboratory is used to conduct real-time corrosion experiments and provides for the remote monitoring of surrounding weather conditions. The newly added flowing seawater immersion facility provides for the immersion testing of materials and devices under controlled conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nitheanandan, T.; Sanderson, D.B.; Kyle, G.
2004-07-01
Atomic Energy of Canada Limited (AECL) has partnered with Argonne National Laboratory to develop a corium thermite prototypical of Candu material and test the concept of ejecting {approx}25 kg of the molten material from a pressure tube with a driving pressure of 10 MPa. This development program has been completed and the technology transferred to AECL. Preparation for the molten-fuel moderator-interaction tests at AECL's Chalk River Laboratories is well underway. A mixture of 0.582 U/0.077 U{sub 3}O{sub 8}/0.151 Zr/0.19 CrO{sub 3} (wt%) as reactant chemicals has been demonstrated to produce a corium consisting of 0.73 UO{sub 2}/0.11 Zr/0.06 ZrO{sub 2}/0.10more » Cr (wt%) at {approx}2400 deg. C. This is comparable to the target Candu specific corium of 0.9 UO{sub 2}/0.1 Zr (wt%), with limited oxidation. The peak melt temperature was confirmed from small-scale thermitic reaction tests. Several small-scale tests were completed to qualify the thermite to ensure operational safety and a quantifiable experimental outcome. The proposed molten-fuel moderator-interaction experiments at Chalk River Laboratories will consist of heating the thermite mixture inside a 1.14-m long insulated pressure tube. Once the molten material has reached the desired temperature of {approx}2400 deg. C, the pressure inside the tube will be raised to about 10 MPa, and the pressure tube will fail at a pre-machined flaw, ejecting the molten material into the surrounding tank of water. The test apparatus, instrumentation, data acquisition and control systems have been assembled, and a series of successful commissioning tests have been completed. (authors)« less
Optimization of wood plastic composite decks
NASA Astrophysics Data System (ADS)
Ravivarman, S.; Venkatesh, G. S.; Karmarkar, A.; Shivkumar N., D.; Abhilash R., M.
2018-04-01
Wood Plastic Composite (WPC) is a new class of natural fibre based composite material that contains plastic matrix reinforced with wood fibres or wood flour. In the present work, Wood Plastic Composite was prepared with 70-wt% of wood flour reinforced in polypropylene matrix. Mechanical characterization of the composite was done by carrying out laboratory tests such as tensile test and flexural test as per the American Society for Testing and Materials (ASTM) standards. Computer Aided Design (CAD) model of the laboratory test specimen (tensile test) was created and explicit finite element analysis was carried out on the finite element model in non-linear Explicit FE code LS - DYNA. The piecewise linear plasticity (MAT 24) material model was identified as a suitable model in LS-DYNA material library, describing the material behavior of the developed composite. The composite structures for decking application in construction industry were then optimized for cross sectional area and distance between two successive supports (span length) by carrying out various numerical experiments in LS-DYNA. The optimized WPC deck (Elliptical channel-2 E10) has 45% reduced weight than the baseline model (solid cross-section) considered in this study with the load carrying capacity meeting acceptance criterion (allowable deflection & stress) for outdoor decking application.
High heat flux testing of CFC composites for the tokamak physics experiment
NASA Astrophysics Data System (ADS)
Valentine, P. G.; Nygren, R. E.; Burns, R. W.; Rocket, P. D.; Colleraine, A. P.; Lederich, R. J.; Bradley, J. T.
1996-10-01
High heat flux (HHF) testing of carbon fiber reinforced carbon composites (CFC's) was conducted under the General Atomics program to develop plasma-facing components (PFC's) for Princeton Plasma Physics Laboratory's tokamak physics experiment (TPX). As part of the process of selecting TPX CFC materials, a series of HHF tests were conducted with the 30 kW electron beam test system (EBTS) facility at Sandia National Laboratories, and with the plasma disruption simulator I (PLADIS-I) facility at the University of New Mexico. The purpose of the tests was to make assessments of the thermal performance and erosion behavior of CFC materials. Tests were conducted with 42 different CFC materials. In general, the CFC materials withstood the rapid thermal pulse environments without fracturing, delaminating, or degrading in a non-uniform manner; significant differences in thermal performance, erosion behavior, vapor evolution, etc. were observed and preliminary findings are presented below. The CFC's exposed to the hydrogen plasma pulses in PLADIS-I exhibited greater erosion rates than the CFC materials exposed to the electron-beam pulses in EBTS. The results obtained support the continued consideration of a variety of CFC composites for TPX PFC components.
Evaluation of liners for a uranium-mill tailings disposal site: a status report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buelt, J.L.; Hale, V.Q.; Barnes, S.M.
1981-05-01
The United States Department of Energy is conducting a program designed to reclaim or stabilize inactive uranium-mill tailings sites. This report presents the status of the Liner Evaluation Program. The purpose of the study was to identify eight prospective lining materials or composites for laboratory testing. The evaluation was performed by 1) reviewing proposed regulatory requirements to define the material performance criteria; 2) reviewing published literature and communicating with industrial and government experts experienced with lining materials and techniques; and 3) characterizing the tailings at three of the sites for calcium concentration, a selection of anions, radionuclides, organic solvents, andmore » acidity levels. The eight materials selected for laboratory testing are: natural soil amended with sodium-saturated montmorillonite (Volclay); locally available clay in conjunction with an asphalt emulsion radon suppression cover; locally available clay in conjunction with a multibarrier radon suppression cover; rubberized asphalt membrane; hydraulic asphalt concrete; chlorosulfonated polyethylene (hypalon) or high-density polyethylene; bentonite, sand and gravel mixture; and catalytic airblown asphalt membrane. The materials will be exposed in test units now being constructed to conditions such as wet/dry cycles, temperature cycles, oxidative environments, ion-exchange elements, etc. The results of the tests will identify the best material for field study. The status report also presents the information gathered during the field studies at Grand Junction, Colorado. Two liners, a bentonite, sand and gravel mixture, and a catalytic airblown asphalt membrane, were installed in a prepared trench and covered with tailings. The liners were instrumented and are being monitored for migration of moisture, radionuclides, and hazardous chemicals. The two liner materials will also be subjected to accelerated laboratory tests for a comparative assessment.« less
Thermocouple Calibration and Accuracy in a Materials Testing Laboratory
NASA Technical Reports Server (NTRS)
Lerch, B. A.; Nathal, M. V.; Keller, D. J.
2002-01-01
A consolidation of information has been provided that can be used to define procedures for enhancing and maintaining accuracy in temperature measurements in materials testing laboratories. These studies were restricted to type R and K thermocouples (TCs) tested in air. Thermocouple accuracies, as influenced by calibration methods, thermocouple stability, and manufacturer's tolerances were all quantified in terms of statistical confidence intervals. By calibrating specific TCs the benefits in accuracy can be as great as 6 C or 5X better compared to relying on manufacturer's tolerances. The results emphasize strict reliance on the defined testing protocol and on the need to establish recalibration frequencies in order to maintain these levels of accuracy.
NASA Technical Reports Server (NTRS)
Benz, F. J.; Dixon, D. S.; Shaw, R. C.
1986-01-01
Testing machine evaluates wear and ignition characteristics of materials in rubbing contact. Offers advantages over other laboratory methods of measuring wear because it simulates operating conditions under which material will actually be used. Machine used to determine wear characteristics, rank and select materials for service with such active oxidizers as oxygen, halogens, and oxides of nitrogen, measure wear characteristics, and determine coefficients of friction.
The Development of Modular Instructional Materials for Physics for One-Year Vocational Students.
ERIC Educational Resources Information Center
Parsons, Ralph
This report describes a project to develop and test a number of individualized vocational physics modules designed to be laboratory-oriented, written at the lowest reading level, and supplemented with audiovisual materials. The report includes descriptions of the procedures used to develop, pilot test, and disseminate the materials. Each of the…
Recent progress and tests of radiation resistant impregnation materials for Nb3Sn coils
NASA Astrophysics Data System (ADS)
Bossert, R.; Krave, S.; Ambrosio, G.; Andreev, N.; Chlachidze, G.; Nobrega, A.; Novitski, I.; Yu, M.; Zlobin, A. V.
2014-01-01
Fermilab is collaborating with Lawrence Berkeley National Laboratory (LBNL) and Brookhaven National Laboratory (BNL) (US-LARP collaboration) to develop a large-aperture Nb3Sn superconducting quadrupole for the Large Hadron Collider (LHC) luminosity upgrade. An important component of this work is the development of materials that are sufficiently radiation resistant for use in critical areas of the upgrade. This paper describes recent progress in characterization of materials, including the baseline CTD101K epoxy, cyanate ester blends, and Matrimid 5292, a bismaleimide-based system. Structural properties of "ten stacks" of cable impregnated with these materials are tested at room and cryogenic temperatures and compared to the baseline CT-101K. Experience with potting 1 and 2 meter long coils with Matrimid 5292 are described. Test results of a single 1-m coil impregnated with Matrimid 5292 are reported and compared to similar coils impregnated with the traditional epoxy.
Development of the Global Measles Laboratory Network.
Featherstone, David; Brown, David; Sanders, Ray
2003-05-15
The routine reporting of suspected measles cases and laboratory testing of samples from these cases is the backbone of measles surveillance. The Global Measles Laboratory Network (GMLN) has developed standards for laboratory confirmation of measles and provides training resources for staff of network laboratories, reference materials and expertise for the development and quality control of testing procedures, and accurate information for the Measles Mortality Reduction and Regional Elimination Initiative. The GMLN was developed along the lines of the successful Global Polio Laboratory Network, and much of the polio laboratory infrastructure was utilized for measles. The GMLN has developed as countries focus on measles control activities following successful eradication of polio. Currently more than 100 laboratories are part of the global network and follow standardized testing and reporting procedures. A comprehensive laboratory accreditation process will be introduced in 2002 with six quality assurance and performance indicators.
21 CFR 211.173 - Laboratory animals.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Laboratory animals. 211.173 Section 211.173 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS... Laboratory animals. Animals used in testing components, in-process materials, or drug products for compliance...
21 CFR 211.173 - Laboratory animals.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 4 2014-04-01 2014-04-01 false Laboratory animals. 211.173 Section 211.173 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS... Laboratory animals. Animals used in testing components, in-process materials, or drug products for compliance...
21 CFR 211.173 - Laboratory animals.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 4 2013-04-01 2013-04-01 false Laboratory animals. 211.173 Section 211.173 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS... Laboratory animals. Animals used in testing components, in-process materials, or drug products for compliance...
21 CFR 211.173 - Laboratory animals.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Laboratory animals. 211.173 Section 211.173 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS... Laboratory animals. Animals used in testing components, in-process materials, or drug products for compliance...
21 CFR 211.173 - Laboratory animals.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 4 2012-04-01 2012-04-01 false Laboratory animals. 211.173 Section 211.173 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS... Laboratory animals. Animals used in testing components, in-process materials, or drug products for compliance...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-14
... certificate from the Secretary of Health and Human Services (the Secretary), before accepting materials derived from the human body for laboratory tests (42 U.S.C. 263a(b)). Laboratories that perform only tests... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-N-0937...
46 CFR 160.076-11 - Incorporation by reference.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Laboratories, Inc., 12 Laboratory Drive, Research Triangle Park, NC 27709-3995 (Phone (919) 549-1400; Facsimile... affected are as follows: American Society for Testing and Materials (ASTM) 100 Barr Harbor Drive, West...
Gasoline and Diesel Fuel Test Methods Additional Resources
Supporting documents on the Direct Final Rule that allows refiners and laboratories to use more current and improved fuel testing procedures for twelve American Society for Testing and Materials analytical test methods.
The quality of veterinary in-clinic and reference laboratory biochemical testing.
Rishniw, Mark; Pion, Paul D; Maher, Tammy
2012-03-01
Although evaluation of biochemical analytes in blood is common in veterinary practice, studies assessing the global quality of veterinary in-clinic and reference laboratory testing have not been reported. The aim of this study was to assess the quality of biochemical testing in veterinary laboratories using results obtained from analyses of 3 levels of assayed quality control materials over 5 days. Quality was assessed by comparison of calculated total error with quality requirements, determination of sigma metrics, use of a quality goal index to determine factors contributing to poor performance, and agreement between in-clinic and reference laboratory mean results. The suitability of in-clinic and reference laboratory instruments for statistical quality control was determined using adaptations from the computerized program, EZRules3. Reference laboratories were able to achieve desirable quality requirements more frequently than in-clinic laboratories. Across all 3 materials, > 50% of in-clinic analyzers achieved a sigma metric ≥ 6.0 for measurement of 2 analytes, whereas > 50% of reference laboratory analyzers achieved a sigma metric ≥ 6.0 for measurement of 6 analytes. Expanded uncertainty of measurement and ± total allowable error resulted in the highest mean percentages of analytes demonstrating agreement between in-clinic and reference laboratories. Owing to marked variation in bias and coefficient of variation between analyzers of the same and different types, the percentages of analytes suitable for statistical quality control varied widely. These findings reflect the current state-of-the-art with regard to in-clinic and reference laboratory analyzer performance and provide a baseline for future evaluations of the quality of veterinary laboratory testing. © 2012 American Society for Veterinary Clinical Pathology.
ERIC Educational Resources Information Center
Boffa, Vittorio; Yue, Yuanzheng; He, Wen
2012-01-01
As part of a laboratory course, undergraduate students were asked to use baker's yeast cells as biotemplate in preparing TiO[subscript 2] powders and to test the photocatalytic activity of the resulting materials. This laboratory experience, selected because of the important environmental implications of soft chemistry and photocatalysis, provides…
MTR,TRA603. EXPERIMENTERS' SPACE ALLOCATIONS IN BASEMENT AS OF 1963. SHIELDED ...
MTR,TRA-603. EXPERIMENTERS' SPACE ALLOCATIONS IN BASEMENT AS OF 1963. SHIELDED CUBICLES WERE IDENTIFIED BY SPONSORING LABORATORY AND ITS TEST HOLE NUMBER IN THE REACTOR, IE, "KAPL HB-1" SIGNIFIED KNOLLS ATOMIC POWER LABORATORY, HORIZONTAL BEAM NO. 1. "WAPD" WAS WESTINGHOUSE ATOMIC POWER DIVISION. CATCH TANKS AND SAMPLE STATIONS FOR TEST LOOPS WERE ASSOCIATED WITH THESE CUBICLES. NOTE DESKS, STORAGE CABINETS, SWITCH GEAR, INSTRUMENT PANELS. PHILLIPS PETROLEUM COMPANY MTR-E-5205, 4/1963. INL INDEX NO. 531-0603-00-706-009757, REV. 5. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Second NBL measurement evaluation program meeting: A summary
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spaletto, M.I.; Clapper, M.; Tolbert, M.E.M.
New Brunswick Laboratory (NBL), the US government`s nuclear materials measurements and reference materials laboratory, administers interlaboratory measurement evaluation programs to evaluate the quality and adequacy of safeguards measurements. The NBL Measurement Evaluation Program covers several types of safeguards analytical measurements. The Safeguards Measurement Evaluation (SME) program distributes test materials destructive measurements of uranium for both elemental concentration and isotopic abundances, and of plutonium for isotopic abundances. The Calorimetry Exchange (CalEx) Program tests the quality of nondestructive measurements of plutonium isotopic abundances by gamma spectroscopy and plutonium concentration by calorimetry. In May 1997, more than 30 representatives from the Department ofmore » Energy (DOE), its contractor laboratories, and Nuclear Regulatory Commission licensees met at NBL in Argonne, Illinois, for the annual meeting of the Measurement Evaluation Program. The summary which follows details key points that were discussed or presented at the meeting.« less
Characterization of 137 Genomic DNA Reference Materials for 28 Pharmacogenetic Genes
Pratt, Victoria M.; Everts, Robin E.; Aggarwal, Praful; Beyer, Brittany N.; Broeckel, Ulrich; Epstein-Baak, Ruth; Hujsak, Paul; Kornreich, Ruth; Liao, Jun; Lorier, Rachel; Scott, Stuart A.; Smith, Chingying Huang; Toji, Lorraine H.; Turner, Amy; Kalman, Lisa V.
2017-01-01
Pharmacogenetic testing is increasingly available from clinical laboratories. However, only a limited number of quality control and other reference materials are currently available to support clinical testing. To address this need, the Centers for Disease Control and Prevention–based Genetic Testing Reference Material Coordination Program, in collaboration with members of the pharmacogenetic testing community and the Coriell Cell Repositories, has characterized 137 genomic DNA samples for 28 genes commonly genotyped by pharmacogenetic testing assays (CYP1A1, CYP1A2, CYP2A6, CYP2B6, CYP2C8, CYP2C9, CYP2C19, CYP2D6, CYP2E1, CYP3A4, CYP3A5, CYP4F2, DPYD, GSTM1, GSTP1, GSTT1, NAT1, NAT2, SLC15A2, SLC22A2, SLCO1B1, SLCO2B1, TPMT, UGT1A1, UGT2B7, UGT2B15, UGT2B17, and VKORC1). One hundred thirty-seven Coriell cell lines were selected based on ethnic diversity and partial genotype characterization from earlier testing. DNA samples were coded and distributed to volunteer testing laboratories for targeted genotyping using a number of commercially available and laboratory developed tests. Through consensus verification, we confirmed the presence of at least 108 variant pharmacogenetic alleles. These samples are also being characterized by other pharmacogenetic assays, including next-generation sequencing, which will be reported separately. Genotyping results were consistent among laboratories, with most differences in allele assignments attributed to assay design and variability in reported allele nomenclature, particularly for CYP2D6, UGT1A1, and VKORC1. These publicly available samples will help ensure the accuracy of pharmacogenetic testing. PMID:26621101
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chiaro, P.J.
A series of tests were performed at Oak Ridge National Laboratory (ORNL) to evaluate and characterize the radiological response of a ''Cricket'' radiation detection system. The ''Cricket'' is manufactured by RAD/COMM Systems Corp., which is located in Ontario, Canada. The system is designed to detect radioactive material that may be contained in scrap metal. The Cricket's detection unit is mounted to the base of a grappler and monitors material, while the grappler's tines hold the material. It can also be used to scan material in an attempt to isolate radioactive material if an alarm occurs. Testing was performed at themore » Environmental Effects Laboratory located at ORNL and operated by the Engineering Science and Technology Division. Tests performed included the following: (1) Background stability, (2) Energy response using {sup 241}Am, {sup 137}Cs, and {sup 60}Co, (3) Surface uniformity, (4) Angular dependence, (5) Alarm actuation, (6) Alarm threshold vs. background, (7) Shielding, (8) Response to {sup 235}U, (9) Response to neutrons using unmoderated {sup 252}Cf, and (10) Response to transient radiation. This report presents a summary of the test results. Background measurements were obtained prior to the performance of each individual test.« less
Advances in radiation detection technologies for responders.
Unterweger, Michael P; Pibida, Leticia S
2005-11-01
The Department of Homeland Security is supporting the development of a large number of standards for first responders. In the area of detection of radioactive and nuclear materials, four new standards (ANSI N42.32, N42.33, N42.34, and N42.35) and their corresponding test and evaluation protocols were developed to meet Department of Homeland Security needs. Testing of the standards and protocols was carried out at the National Institute of Standards and Technology, Oak Ridge National Laboratory, Pacific Northwest National Laboratory, Los Alamos National Laboratory, and Lawrence Livermore National Laboratory.
Integrated Data Collection Analysis (IDCA) Program - AN and Bullseye Smokeless Powder
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.
The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of ammonium nitrate (AN) mixed with Bullseye® smokeless powder (Gunpowder). The participants found the AN/Gunpowder to: 1) have a range of sensitivity to impact, comparable to or less than RDX, 2) be fairly insensitive to friction as measured by BAM and ABL, 3) have a range for ESD, from insensitive to more sensitive than PETN, and 4) have thermal sensitivity aboutmore » the same as PETN and Gunpowder. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study has the potential to suggest new guidelines and methods and possibly establish the SSST testing accuracies needed when developing safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods. Note, however, the test procedures differ among the laboratories. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent. Keywords: Small-scale safety testing, proficiency test, impact-, friction-, spark discharge-, thermal testing, round-robin test, safety testing protocols, HME, RDX, potassium perchlorate, potassium chlorate, sodium chlorate, sugar, dodecane, PETN, carbon, ammonium nitrate, Gunpowder, Bullseye® smokeless powder.« less
The Evolving Role of Field and Laboratory Seismic Measurements in Geotechnical Engineering
NASA Astrophysics Data System (ADS)
Stokoe, K. H.
2017-12-01
The geotechnical engineering has been faced with the problem of characterizing geological materials for site-specific design in the built environment since the profession began. When one of the design requirements included determining the dynamic response of important and critical facilities to earthquake shaking or other types of dynamic loads, seismically-based measurements in the field and laboratory became important tools for direct characterization of the stiffnesses and energy dissipation (material damping) of these materials. In the 1960s, field seismic measurements using small-strain body waves were adapted from exploration geophysics. At the same time, laboratory measurements began using dynamic, torsional, resonant-column devices to measure shear stiffness and material damping in shear. The laboratory measurements also allowed parameters such as material type, confinement state, and nonlinear straining to be evaluated. Today, seismic measurements are widely used and evolving because: (1) the measurements have a strong theoretical basis, (2) they can be performed in the field and laboratory, thus forming an important link between these measurements, and (3) in recent developments in field testing involving surface waves, they are noninvasive which makes them cost effective in comparison to other methods. Active field seismic measurements are used today over depths ranging from about 5 to 1000 m. Examples of shear-wave velocity (VS) profiles evaluated using boreholes, penetrometers, suspension logging, and Rayleigh-type surface waves are presented. The VS measurements were performed in materials ranging from uncemented soil to unweathered rock. The coefficients of variation (COVs) in the VS profiles are generally less than 0.15 over sites with surface areas of 50 km2 or more as long as material types are not laterally mixed. Interestingly, the largest COVs often occur around layer boundaries which vary vertically. It is also interesting to observe how the stiffness of rock near the ground surface is generally overestimated. Finally, intact specimens of the geological materials recovered from many sites were tested dynamically in the laboratory. Values of VS measured in the field and laboratory are compared, and biases in VS at soil versus rock sites are shown to exhibit opposite trends.
2003-08-21
KENNEDY SPACE CENTER, FLA. - On a tour of the KSC Beach Corrosion Test Site, Testbed Manager Louis MacDowell (right) explains to Center Director Jim Kennedy about the test blocks being used to test a newly developed coating to protect steel inside concrete. Between MacDowell and Kennedy are Dr. Paul Hintze and Lead Scientist Dr. Luz Marina Calle. The KSC Beach Corrosion Test Site was established in the 1960s and has provided more than 30 years of historical information on the long-term performance of many materials in use at KSC and other locations around the world. Located 100 feet from the Atlantic Ocean approximately 1 mile south of the Space Shuttle launch sites, the test facility includes an atmospheric exposure site, a flowing seawater exposure site, and an on-site electrochemistry laboratory and monitoring station. The beach laboratory is used to conduct real-time corrosion experiments and provides for the remote monitoring of surrounding weather conditions. The newly added flowing seawater immersion facility provides for the immersion testing of materials and devices under controlled conditions.
NASA Technical Reports Server (NTRS)
Hirschberg, M. H.
1978-01-01
Twenty laboratories in six countries participated in testing their own materials of interest under their own laboratory conditions. In this way the results obtained provided validation of the Strainrange Partitioning (SRP) method for a wide range of materials and insured maximum usefulness to each of the participating laboratories. The various investigators shared their findings, thus providing the basis for an in-depth evaluation of the SRP method. While the results were variable from laboratory to laboratory, most investigators agreed that the SRP method was a significant step toward life prediction in the presence of high temperature and cyclic stresses.
Evaluation of heat- and blast-protection materials
NASA Technical Reports Server (NTRS)
Morrison, J. D.; Lockhart, B. J.
1971-01-01
A program was initiated at the Kennedy Space Center in December 1967 and conducted through December 1969 to evaluate the performance of heat- and blast-protection materials for ground support equipment used during the Apollo/Saturn launches. Materials believed to be generally suitable for heat and blast protection were subjected to launch-exposure tests. Tests were made during the Apollo/Saturn 502, 503, and 505 launches. Tests were also made in a local laboratory, as an alternative to the restrictive requirements of launch-exposure tests, to determine the effects of torch-flame exposure on ablative materials. Five materials were found to be satisfactory in all major test categories. It was determined that torch-flame tests can probably be utilized as an acceptable substitute for the booster-engine-exhaust exposure tests for basic screening of candidate materials.
Isotherm Sensor Calibration Program for Mars Science Laboratory Heat Shield Flight Data Analysis
NASA Technical Reports Server (NTRS)
Santos, Jose A.; Oishi, Tomo; Martinez, Ed R.
2011-01-01
Seven instrumented sensor plugs were installed on the Mars Science Laboratory heat shield in December 2008 as part of the Mars Science Laboratory Entry, Descent, and Landing Instrumentation (MEDLI) project. These sensor plugs contain four in-depth thermocouples and one Hollow aErothermal Ablation and Temperature (HEAT) sensor. The HEAT sensor follows the time progression of a 700 C isotherm through the thickness of a thermal protection system (TPS) material. The data can be used to infer char depth and, when analyzed in conjunction with the thermocouple data, the thermal gradient through the TPS material can also be determined. However, the uncertainty on the isotherm value is not well defined. To address this uncertainty, a team at NASA Ames Research Center is carrying out a HEAT sensor calibration test program. The scope of this test program is described, and initial results from experiments conducted in the laboratory to study the isotherm temperature of the HEAT sensor are presented. Data from the laboratory tests indicate an isotherm temperature of 720 C 60 C. An overview of near term arc jet testing is also given, including preliminary data from 30.48cm 30.48cm PICA panels instrumented with two MEDLI sensor plugs and tested in the NASA Ames Panel Test Facility. Forward work includes analysis of the arc jet test data, including an evaluation of the isotherm value based on the instant in time when it reaches a thermocouple depth.
Laboratory Characterization of White Masonry Concrete
2006-09-01
procedures given in American Society for Testing and Materials (ASTM) D 2216 (ASTM 2002e). Based on the appropriate values of posttest water content...properties of the material. All of the mechanical property tests were conducted quasi -statically with axial strain rates on the order of 10-4 to 10...mechanical property tests, nondestructive pulse-velocity measurements were performed on each specimen. The TXC tests exhibited a continuous increase
The Usability of Rock-Like Materials for Numerical Studies on Rocks
NASA Astrophysics Data System (ADS)
Zengin, Enes; Abiddin Erguler, Zeynal
2017-04-01
The approaches of synthetic rock material and mass are widely used by many researchers for understanding the failure behavior of different rocks. In order to model the failure behavior of rock material, researchers take advantageous of different techniques and software. But, the majority of all these instruments are based on distinct element method (DEM). For modeling the failure behavior of rocks, and so to create a fundamental synthetic rock material model, it is required to perform related laboratory experiments for providing strength parameters. In modelling studies, model calibration processes are performed by using parameters of intact rocks such as porosity, grain size, modulus of elasticity and Poisson ratio. In some cases, it can be difficult or even impossible to acquire representative rock samples for laboratory experiments from heavily jointed rock masses and vuggy rocks. Considering this limitation, in this study, it was aimed to investigate the applicability of rock-like material (e.g. concrete) to understand and model the failure behavior of rock materials having complex inherent structures. For this purpose, concrete samples having a mixture of %65 cement dust and %35 water were utilized. Accordingly, intact concrete samples representing rocks were prepared in laboratory conditions and their physical properties such as porosity, pore size and density etc. were determined. In addition, to acquire the mechanical parameters of concrete samples, uniaxial compressive strength (UCS) tests were also performed by simultaneously measuring strain during testing. The measured physical and mechanical properties of these extracted concrete samples were used to create synthetic material and then uniaxial compressive tests were modeled and performed by using two dimensional discontinuum program known as Particle Flow Code (PFC2D). After modeling studies in PFC2D, approximately similar failure mechanism and testing results were achieved from both experimental and artificial simulations. The results obtained from these laboratory tests and modelling studies were compared with the other researcher's studies in respect to failure mechanism of different type of rocks. It can be concluded that there is similar failure mechanism between concrete and rock materials. Therefore, the results obtained from concrete samples that would be prepared at different porosity and pore sizes can be used in future studies in selection micro-mechanical and physical properties to constitute synthetic rock materials for understanding failure mechanism of rocks having complex inherent structures such as vuggy rocks or heavily jointed rock masses.
Juhel-Gaugain, M; McEvoy, J D; VanGinkel, L A
2000-12-01
The experimental design of a material certification programme is described. The matrix reference materials (RMs) comprised chlortetracycline (CTC)-containing and CTC-free lyophilised porcine liver, kidney and muscle produced under the European Commission's Standards Measurements and Testing (SMT) programme. The aim of the certification programme was to determine accurately and precisely the concentration of CTC and 4-epi-chlortetracycline (epi-CTC) contained in the RMs. A multi-laboratory approach was used to certify analyte concentrations. Participants (n = 19) were instructed to strictly adhere to previously established guidelines. Following the examination of analytical performance criteria, statistical manipulation of results submitted by 13 laboratories, (6 withdrew) allowed an estimate to be made of the true value of the analyte content. The Nalimov test was used for detection of outlying results. The Cochran and Bartlett tests were employed for testing the homogeneity of variances. The normality of results distribution was tested according to the Kolmogorov-Smirnov-Lilliefors test. One-way analysis of variance (ANOVA) was employed to calculate the within and between-laboratory standard deviations, the overall mean and confidence interval for the CTC and epi-CTC content of each of the RMs. Certified values were within or very close to the target concentration ranges specified in the SMT contract. These studies have demonstrated the successful production and certification of CTC-containing and CTC-free porcine RMs.
Opportunities for Nondestructive Evaluation: Quantitative Characterization (Postprint)
2017-07-01
between the design and the as- manufactured and, ultimately, the as-maintained state. As this occurs with the article of interest being placed in...TESTING (STINFO COPY) AIR FORCE RESEARCH LABORATORY MATERIALS AND MANUFACTURING DIRECTORATE WRIGHT-PATTERSON AIR FORCE BASE, OH 45433-7750 AIR FORCE...MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSORING/MONITORING AGENCY ACRONYM(S) Air Force Research Laboratory Materials and Manufacturing
The estimation of parameter compaction values for pavement subgrade stabilized with lime
NASA Astrophysics Data System (ADS)
Lubis, A. S.; Muis, Z. A.; Simbolon, C. A.
2018-02-01
The type of soil material, field control, maintenance and availability of funds are several factors that must be considered in compaction of the pavement subgrade. In determining the compaction parameters in laboratory desperately requires considerable materials, time and funds, and reliable laboratory operators. If the result of soil classification values can be used to estimate the compaction parameters of a subgrade material, so it would save time, energy, materials and cost on the execution of this work. This is also a clarification (cross check) of the work that has been done by technicians in the laboratory. The study aims to estimate the compaction parameter values ie. maximum dry unit weight (γdmax) and optimum water content (Wopt) of the soil subgrade that stabilized with lime. The tests that conducted in the laboratory of soil mechanics were to determine the index properties (Fines and Liquid Limit/LL) and Standard Compaction Test. Soil samples that have Plasticity Index (PI) > 10% were made with additional 3% lime for 30 samples. By using the Goswami equation, the compaction parameter values can be estimated by equation γd max # = -0,1686 Log G + 1,8434 and Wopt # = 2,9178 log G + 17,086. From the validation calculation, there was a significant positive correlation between the compaction parameter values laboratory and the compaction parameter values estimated, with a 95% confidence interval as a strong relationship.
Valeriani, F; Gianfranceschi, G; Vitali, M; Protano, C; Romano Spica, V
2017-01-01
Hygiene and surveillance in swimming pools are established by WHO Guidelines and national laws. Progress in water management and pool construction is revolutionizing the field, introducing new materials, systems, disinfection procedures or monitoring markers. Innovation advances challenge the upgrading of safety and quality in pools and the appropriate implementation of guidelines. In order to provide a device for laboratory test, a prototype was realized and applied to study and compare swimming pool materials and treatments. A pool scale-model was engineered and evaluated by computational fluid dynamics algorithms. An automated real time monitoring assured steady state. Critical control points along the water circuit were made accessible to allow the placing of different biocides or water sampling. Simulations were safely performed in a standard hood. Materials for pool surfaces and pipelines were evaluated for biofilm formation under different disinfection conditions. Adherent microorganisms were assayed by mfDNA analysis using real time PCR. The prototype reached the steady state within 5-25 hours under different conditions, showing chemical, physical and fluid-dynamic stability. A method was optimized for testing materials showing their different response to biofilm induction. Several innovative PVC samples displayed highest resistance to bacterial adhesion. A device and method was developed for testing swimming pool hygienic parameters in laboratory. It allowed to test materials for pools hygiene and maintenance, including biofilm formation. It can be applied to simulate contaminations under different water treatments or disinfection strategies. It may support technical decisions and help policymakers in acquiring evidences for comparing or validating innovative solutions.
A Reference Method for Measuring Emissions of SVOCs in ...
Semivolatile organic compounds (SVOCs) are indoor air pollutants that may may have significant adverse effects on human health, and emission of SVOCs from building materials and consumer products is of growing concern. Few chamber studies have been conducted due to the challenges associated with SVOC analysis and the lack of validation procedures. Thus there is an urgent need for a reliable and accurate chamber test method to verify the performance of these measurements. A reference method employing a specially-designed chamber and experimental protocol has been developed and is undergoing extensive evaluation. A pilot interlaboratory study (ILS) has been conducted with five laboratories performing chamber tests under identical conditions. Results showed inter-laboratory variations at 25% for SVOC emission rates, with greater agreement observed between intra-laboratory measurements for most of the participating laboratories. The measured concentration profiles also compared reasonably well to the mechanistic model, demonstrating the feasibility of the proposed reference method to independently assess laboratory performance and validate SVOC emission tests. There is an urgent need for improved understanding of the measurement uncertainties associated with SVOC emissions testing. The creation of specially-designed chambers and well-characterized materials serves as a critical prerequisite for improving the procedure used to measure SVOCs emitted from indoor
Developing a laboratory protocol for asphalt binder recovery.
DOT National Transportation Integrated Search
2014-10-01
Asphalt binder extraction and recovery are common laboratory procedures used to provide material for research and quality : assurance testing. The most common methods of recovery performed today include the Abson method and the rotary evaporator : (o...
Hot Corrosion Test Facility at the NASA Lewis Special Projects Laboratory
NASA Technical Reports Server (NTRS)
Robinson, Raymond C.; Cuy, Michael D.
1994-01-01
The Hot Corrosion Test Facility (HCTF) at the NASA Lewis Special Projects Laboratory (SPL) is a high-velocity, pressurized burner rig currently used to evaluate the environmental durability of advanced ceramic materials such as SiC and Si3N4. The HCTF uses laboratory service air which is preheated, mixed with jet fuel, and ignited to simulate the conditions of a gas turbine engine. Air, fuel, and water systems are computer-controlled to maintain test conditions which include maximum air flows of 250 kg/hr (550 lbm/hr), pressures of 100-600 kPa (1-6 atm), and gas temperatures exceeding 1500 C (2732 F). The HCTF provides a relatively inexpensive, yet sophisticated means for researchers to study the high-temperature oxidation of advanced materials, and the injection of a salt solution provides the added capability of conducting hot corrosion studies.
Constitutive Soil Properties for Mason Sand and Kennedy Space Center
NASA Technical Reports Server (NTRS)
Thomas, Michael A.; Chitty, Daniel E.
2011-01-01
Accurate soil models are required for numerical simulations of land landings for the Orion Crew Exploration Vehicle (CEV). This report provides constitutive material models for two soil conditions at Kennedy Space Center (KSC) and four conditions of Mason Sand. The Mason Sand is the test sand for LaRC s drop tests and swing tests of the Orion. The soil models are based on mechanical and compressive behavior observed during geotechnical laboratory testing of remolded soil samples. The test specimens were reconstituted to measured in situ density and moisture content. Tests included: triaxial compression, hydrostatic compression, and uniaxial strain. A fit to the triaxial test results defines the strength envelope. Hydrostatic and uniaxial tests define the compressibility. The constitutive properties are presented in the format of LSDYNA Material Model 5: Soil and Foam. However, the laboratory test data provided can be used to construct other material models. The soil models are intended to be specific to the soil conditions they were tested at. The two KSC models represent two conditions at KSC: low density dry sand and high density in-situ moisture sand. The Mason Sand model was tested at four conditions which encompass measured conditions at LaRC s drop test site.
High temperature material interactions of thermoelectric systems using silicon germanium.
NASA Technical Reports Server (NTRS)
Stapfer, G.; Truscello, V. C.
1973-01-01
The efficient use of silicon germanium thermoelectric material for radioisotope thermoelectric generators (RTG) is achieved by operation at relatively high temperatures. The insulation technique which is most appropriate for this application uses multiple layers of molybdenum foil and astroquartz. Even so, the long term operation of these materials at elevated temperatures can cause material interaction to occur within the system. To investigate these material interactions, the Jet Propulsion Laboratory is currently testing a number of thermoelectric modules which use four silicon germanium thermoelectric couples in conjunction with the multifoil thermal insulation. The paper discusses the results of the ongoing four-couple module test program and correlates test results with those of a basic material test program.
Miley, Don
2017-12-21
The Advanced Test Reactor at Idaho National Laboratory is the foremost nuclear materials test reactor in the world. This virtual tour describes the reactor, how experiments are conducted, and how spent nuclear fuel is handled and stored.
Buttner, Mark P.; Cruz, Patricia; Stetzenbach, Linda D.; Cronin, Tracy
2007-01-01
This research was designed to evaluate surface sampling protocols for use with culture and quantitative PCR (QPCR) amplification assay for detection of the gram-negative bacterial biothreat simulant Erwinia herbicola on a variety of surface materials. Surfaces selected for evaluation were wood laminate, glass and computer monitor screens, metal file cabinets, plastic arena seats, nylon seat cushions, finished concrete flooring, and vinyl tile flooring. Laboratory and test chamber studies were performed to evaluate two sampling methods, a sponge and a macrofoam swab, for detection of E. herbicola on surface materials. In laboratory trials, seven materials were inoculated with a known concentration of E. herbicola cells and samples were collected from the surfaces of the materials to determine sampling efficiencies. Culture analysis was ineffective for assessing E. herbicola collection efficiency because very few culturable cells were obtained from surface samples. QPCR demonstrated that E. herbicola DNA was present in high concentrations on all of the surface samples, and sampling efficiencies ranged from 0.7 to 52.2%, depending on the sampling method and the surface material. The swab was generally more efficient than the sponge for collection of E. herbicola from surfaces. Test chamber trials were also performed in which E. herbicola was aerosolized into the chamber and allowed to settle onto test materials. Surface sampling results supported those obtained in laboratory trials. The results of this study demonstrate the capabilities of QPCR to enhance the detection and enumeration of biocontaminants on surface materials and provide information on the comparability of sampling methods. PMID:17416685
Buttner, Mark P; Cruz, Patricia; Stetzenbach, Linda D; Cronin, Tracy
2007-06-01
This research was designed to evaluate surface sampling protocols for use with culture and quantitative PCR (QPCR) amplification assay for detection of the gram-negative bacterial biothreat simulant Erwinia herbicola on a variety of surface materials. Surfaces selected for evaluation were wood laminate, glass and computer monitor screens, metal file cabinets, plastic arena seats, nylon seat cushions, finished concrete flooring, and vinyl tile flooring. Laboratory and test chamber studies were performed to evaluate two sampling methods, a sponge and a macrofoam swab, for detection of E. herbicola on surface materials. In laboratory trials, seven materials were inoculated with a known concentration of E. herbicola cells and samples were collected from the surfaces of the materials to determine sampling efficiencies. Culture analysis was ineffective for assessing E. herbicola collection efficiency because very few culturable cells were obtained from surface samples. QPCR demonstrated that E. herbicola DNA was present in high concentrations on all of the surface samples, and sampling efficiencies ranged from 0.7 to 52.2%, depending on the sampling method and the surface material. The swab was generally more efficient than the sponge for collection of E. herbicola from surfaces. Test chamber trials were also performed in which E. herbicola was aerosolized into the chamber and allowed to settle onto test materials. Surface sampling results supported those obtained in laboratory trials. The results of this study demonstrate the capabilities of QPCR to enhance the detection and enumeration of biocontaminants on surface materials and provide information on the comparability of sampling methods.
Kalman, Lisa; Tarleton, Jack; Hitch, Monica; Hegde, Madhuri; Hjelm, Nick; Berry-Kravis, Elizabeth; Zhou, Lili; Hilbert, James E.; Luebbe, Elizabeth A.; Moxley, Richard T.; Toji, Lorraine
2014-01-01
Myotonic dystrophy type 1 (DM1) is caused by expansion of a CTG triplet repeat in the 3′ untranslated region of the DMPK gene that encodes a serine-threonine kinase. Patients with larger repeats tend to have a more severe phenotype. Clinical laboratories require reference and quality control materials for DM1 diagnostic and carrier genetic testing. Well-characterized reference materials are not available. To address this need, the Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the genetic testing community, the National Registry of Myotonic Dystrophy and Facioscapulohumeral Muscular Dystrophy Patients and Family Members, and the Coriell Cell Repositories, has established and characterized cell lines from patients with DM1 to create a reference material panel. The CTG repeats in genomic DNA samples from 10 DM1 cell lines were characterized in three clinical genetic testing laboratories using PCR and Southern blot analysis. DMPK alleles in the samples cover four of five DM1 clinical categories: normal (5 to 34 repeats), mild (50 to 100 repeats), classical (101 to 1000 repeats), and congenital (>1000 repeats). We did not identify or establish Coriell cell lines in the premutation range (35 to 49 repeats). These samples are publicly available for quality control, proficiency testing, test development, and research and should help improve the accuracy of DM1 testing. PMID:23680132
Laboratory study of PCBs transport from primary sources to ...
The sorption of airborne polychlorinated biphenyls (PCBs) by twenty building materials and their subsequent re-emission (desorption) from concrete were investigated using two 53-L environmental chambers connected in series with a field-collected caulk in the source chamber serving as a stable source of PCBs and building materials in the test chamber. During the tests, the PCB concentrations in the outlet air of the test chamber were monitored and the building materials were removed from the test chamber at different times to determine their PCB content. Among the materials tested, a petroleum-based paint, a latex paint, and a certain type of carpet were among the strongest sinks. Solvent-free epoxy coating, certain types of flooring materials, and brick were among the weakest sinks. For a given sink material, PCB congeners with lower vapor pressures were sorbed in larger quantities. Rough estimates of the partition and diffusion coefficients were obtained by applying a sink model to the data acquired from the chamber studies. A desorption test with the concrete panels showed that re-emission is a slow process, suggesting that PCB sinks, e.g. concrete, can release PCBs into the air for a prolonged period of time (years or decades). This study could fill some of the data gaps associated with the characterization of PCB sinks in contaminated buildings. This paper summarizes the laboratory research results for PCB transport from primary sources to PCB sinks, includ
Towards a standardization of biomethane potential tests.
Holliger, Christof; Alves, Madalena; Andrade, Diana; Angelidaki, Irini; Astals, Sergi; Baier, Urs; Bougrier, Claire; Buffière, Pierre; Carballa, Marta; de Wilde, Vinnie; Ebertseder, Florian; Fernández, Belén; Ficara, Elena; Fotidis, Ioannis; Frigon, Jean-Claude; de Laclos, Hélène Fruteau; Ghasimi, Dara S M; Hack, Gabrielle; Hartel, Mathias; Heerenklage, Joern; Horvath, Ilona Sarvari; Jenicek, Pavel; Koch, Konrad; Krautwald, Judith; Lizasoain, Javier; Liu, Jing; Mosberger, Lona; Nistor, Mihaela; Oechsner, Hans; Oliveira, João Vítor; Paterson, Mark; Pauss, André; Pommier, Sébastien; Porqueddu, Isabella; Raposo, Francisco; Ribeiro, Thierry; Rüsch Pfund, Florian; Strömberg, Sten; Torrijos, Michel; van Eekert, Miriam; van Lier, Jules; Wedwitschka, Harald; Wierinck, Isabella
2016-12-01
Production of biogas from different organic materials is a most interesting source of renewable energy. The biomethane potential (BMP) of these materials has to be determined to get insight in design parameters for anaerobic digesters. Although several norms and guidelines for BMP tests exist, inter-laboratory tests regularly show high variability of BMPs for the same substrate. A workshop was held in June 2015, in Leysin, Switzerland, with over 40 attendees from 30 laboratories around the world, to agree on common solutions to the conundrum of inconsistent BMP test results. This paper presents the consensus of the intense roundtable discussions and cross-comparison of methodologies used in respective laboratories. Compulsory elements for the validation of BMP results were defined. They include the minimal number of replicates, the request to carry out blank and positive control assays, a criterion for the test duration, details on BMP calculation, and last but not least criteria for rejection of the BMP tests. Finally, recommendations on items that strongly influence the outcome of BMP tests such as inoculum characteristics, substrate preparation, test setup, and data analysis are presented to increase the probability of obtaining validated and reproducible results.
21 CFR 660.32 - Collection of source material.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.32 Collection of source material. Blood for Reagent Red Blood Cells from donors of peripheral blood...
21 CFR 660.32 - Collection of source material.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.32 Collection of source material. Blood for Reagent Red Blood Cells from donors of peripheral blood...
21 CFR 660.32 - Collection of source material.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.32 Collection of source material. Blood for Reagent Red Blood Cells from donors of peripheral blood...
21 CFR 660.32 - Collection of source material.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.32 Collection of source material. Blood for Reagent Red Blood Cells from donors of peripheral blood...
Kalman, Lisa V; Datta, Vivekananda; Williams, Mickey; Zook, Justin M; Salit, Marc L; Han, Jin Yeong
2016-11-01
Characterized reference materials (RMs) are needed for clinical laboratory test development and validation, quality control procedures, and proficiency testing to assure their quality. In this article, we review the development and characterization of RMs for clinical molecular genetic tests. We describe various types of RMs and how to access and utilize them, especially focusing on the Genetic Testing Reference Materials Coordination Program (Get-RM) and the Genome in a Bottle (GIAB) Consortium. This review also reinforces the need for collaborative efforts in the clinical genetic testing community to develop additional RMs.
Cherenkov and Scintillation Properties of Cubic Zirconium
NASA Technical Reports Server (NTRS)
Christl, M.J.; Adams, J.H.; Parnell, T.A.; Kuznetsov, E.N.
2008-01-01
Cubic zirconium (CZ) is a high index of refraction (n =2.17) material that we have investigated for Cherenkov counter applications. Laboratory and proton accelerator tests of an 18cc sample of CZ show that the expected fast Cherenkov response is accompanied by a longer scintillation component that can be separated by pulse shaping. This presents the possibility of novel particle spectrometers which exploits both properties of CZ. Other high index materials being examined for Cherenkov applications will be discussed. Results from laboratory tests and an accelerator exposure will be presented and a potential application in solar energetic particle instruments will be discussed
2002-10-11
KENNEDY SPACE CENTER, FLA. -- Pete Engel, an engineering specialist in Wyle Laboratory's Nondestructive Testing Laboratory at KSC, explains the testing being performed on a 100-pound Mundrabilla meteorite sample. The one-of-a-kind meteorite was found 36 years ago in Australia and is on loan to Marshall Space Flight Center (MSFC) from the Smithsonian Institution's National Museum of Natural History. Dr. Donald Gillies, discipline scientist for materials science at MSFC's Microgravity Science and Applications Department, is the Principal Investigator. The studies may help provide the science community and industry with fundamental knowledge for use in the design of advanced materials.
2002-10-11
KENNEDY SPACE CENTER, FLA. -- Pete Engel, an engineering specialist in Wyle Laboratory's Nondestructive Testing Laboratory at KSC, explains the testing being performed on a 100-pound Mundrabilla meteorite sample. The one-of-a-kind meteorite was found 36 years ago in Australia and is on loan to Marshall Space Flight Center (MSFC) from the Smithsonian Institution's National Museum of Natural History. Dr. Donald Gillies, discipline scientist for materials science at MSFC's Microgravity Science and Applications Department, is the Principal Investigator. The studies may help provide the science community and industry with fundamental knowledge for use in the design of advanced materials.
Round robin test for odour testing of migration waters.
Rapp, Thomas; Günther, Herbert
2015-04-15
For a round robin test for EN 1420-1 (Odour assessment for organic materials in contact with drinking water) with 14 contributing laboratories from 10 European countries segments of a plastic pipe were sent to the laboratories which performed a migration test and an odour analysis of the migration waters (water that had contact with the organic material) according to the procedure described in the standard from 1999. In addition reference substances (Methyl tert-butyl ether, 1-butanol and hexanal) were investigated for their suitability to qualify the panels and the individual panellists. Methyl tert-butyl ether (MtBE) and 1-butanol proved to be suitable for this purpose, whereas hexanal showed a wide distribution of the individual odour threshold concentrations. Both possible testing options (unforced and forced choice) were performed and gave similar results. However, with respect to the qualification of the panellists and the data analysis the unforced choice procedure showed advantages. As human olfactory perception is used for the analysis, the reproducibility and the comparability between laboratories is of particular concern. For the pipe material the TON results of the different laboratories were in a range of ±1.5 dilutions based on a dilution factor of 2. This might be improved by taking the individual sensitivities of the panellists into account more strongly. Appropriate measures for the improvement of the test method appear to be the use of the proposed reference substances for the training of the panellists as well as the auditing and the selection of the panellists. The results of this round robin test are used in the revision process of the standard. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Wallace, John F.; Zdankiewicz, Edward M.; Schmidt, Robert N.
1991-01-01
The development of advanced materials and structures for long-term use in space is described with specific reference given to applications to the Space Station Freedom and the lunar base. A flight-testing program is described which incorporates experiments regarding the passive effects of space travel such as material degradation with active materials experiments such as the Materials Exposure Flight Experiment. Also described is a research and development program for materials such as organic coatings and polymeric composites, and a simulation laboratory is described which permits the analysis of materials in the laboratory. The methods of investigation indicate that the NASA Center for the Commercial Development of Space facilitates the understanding of material degradation in space.
Naroznova, Irina; Møller, Jacob; Scheutz, Charlotte
2016-04-01
This study is dedicated to characterising the chemical composition and biochemical methane potential (BMP) of individual material fractions in untreated Danish source-separated organic household waste (SSOHW). First, data on SSOHW in different countries, available in the literature, were evaluated and then, secondly, laboratory analyses for eight organic material fractions comprising Danish SSOHW were conducted. No data were found in the literature that fully covered the objectives of the present study. Based on laboratory analyses, all fractions were assigned according to their specific properties in relation to BMP, protein content, lipids, lignocellulose biofibres and easily degradable carbohydrates (carbohydrates other than lignocellulose biofibres). The three components in lignocellulose biofibres, i.e. lignin, cellulose and hemicellulose, were differentiated, and theoretical BMP (TBMP) and material degradability (BMP from laboratory incubation tests divided by TBMP) were expressed. Moreover, the degradability of lignocellulose biofibres (the share of volatile lignocellulose biofibre solids degraded in laboratory incubation tests) was calculated. Finally, BMP for average SSOHW composition in Denmark (untreated) was calculated, and the BMP contribution of the individual material fractions was then evaluated. Material fractions of the two general waste types, defined as "food waste" and "fibre-rich waste," were found to be anaerobically degradable with considerable BMP. Material degradability of material fractions such as vegetation waste, moulded fibres, animal straw, dirty paper and dirty cardboard, however, was constrained by lignin content. BMP for overall SSOHW (untreated) was 404 mL CH4 per g VS, which might increase if the relative content of material fractions, such as animal and vegetable food waste, kitchen tissue and dirty paper in the waste, becomes larger. Copyright © 2016 Elsevier Ltd. All rights reserved.
Mechanical Testing of Silicon Carbide on MISSE-7
2012-07-15
JS) ii Abstract Silicon carbide ( SiC ) mechanical test specimens were included on the second Optical and Reflector Materials Experiment (ORMatE II...2. Vendor 2 EFS Weibull Results (normalized to Extra Disks Weibull parameters) 12 1. Introduction Silicon carbide ( SiC ) mechanical test...AEROSPACE REPORT NO ATR-2012(8921)-5 Mechanical Testing of Silicon Carbide on MISSE-7 Jul> 15. 2012 David B. Witkin Space Materials Laboratory
Source Recertification, Refurbishment, and Transfer Logistics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gastelum, Zoe N.; Duckworth, Leesa L.; Greenfield, Bryce A.
2013-09-01
The 2012 Gap Analysis of Department of Energy Radiological Sealed Sources, Standards, and Materials for Safeguards Technology Development [1] report, and the subsequent Reconciliation of Source Needs and Surpluses across the U.S. Department of Energy National Laboratory Complex [2] report, resulted in the identification of 33 requests for nuclear or radiological sealed sources for which there was potentially available, suitable material from within the U.S. Department of Energy (DOE) complex to fill the source need. Available, suitable material was defined by DOE laboratories as material slated for excess, or that required recertification or refurbishment before being used for safeguards technologymore » development. This report begins by outlining the logistical considerations required for the shipment of nuclear and radiological materials between DOE laboratories. Then, because of the limited need for transfer of matching sources, the report also offers considerations for an alternative approach – the shipment of safeguards equipment between DOE laboratories or technology testing centers. Finally, this report addresses repackaging needs for the two source requests for which there was available, suitable material within the DOE complex.« less
Evaluation of high performance pavement and bridge deck wearing surface repair materials.
DOT National Transportation Integrated Search
2016-08-01
This project provided for a laboratory and field testing of several high performance repair materials for : pavements and concrete bridge decks. The main purpose was to provide ODOT with materials and procedures : to shorten road and bridge closures....
Educational ultrasound nondestructive testing laboratory.
Genis, Vladimir; Zagorski, Michael
2008-09-01
The ultrasound nondestructive evaluation (NDE) of materials course was developed for applied engineering technology students at Drexel University's Goodwin College of Professional Studies. This three-credit, hands-on laboratory course consists of two parts: the first part with an emphasis on the foundations of NDE, and the second part during which ultrasound NDE techniques are utilized in the evaluation of parts and materials. NDE applications are presented and applied through real-life problems, including calibration and use of the latest ultrasonic testing instrumentation. The students learn engineering and physical principles of measurements of sound velocity in different materials, attenuation coefficients, material thickness, and location and dimensions of discontinuities in various materials, such as holes, cracks, and flaws. The work in the laboratory enhances the fundamentals taught during classroom sessions. This course will ultimately result in improvements in the educational process ["The greater expectations," national panel report, http://www.greaterexpectations.org (last viewed February, 2008); R. M. Felder and R. Brent "The intellectual development of Science and Engineering Students. Part 2: Teaching to promote growth," J. Eng. Educ. 93, 279-291 (2004)] since industry is becoming increasingly reliant on the effective application of NDE technology and the demand on NDE specialists is increasing. NDE curriculum was designed to fulfill levels I and II NDE in theory and training requirements, according to American Society for Nondestructive Testing, OH, Recommended Practice No. SNT-TC-1A (2006).
Modeling Natural Space Ionizing Radiation Effects on External Materials
NASA Technical Reports Server (NTRS)
Alstatt, Richard L.; Edwards, David L.; Parker, Nelson C. (Technical Monitor)
2000-01-01
Predicting the effective life of materials for space applications has become increasingly critical with the drive to reduce mission cost. Programs have considered many solutions to reduce launch costs including novel, low mass materials and thin thermal blankets to reduce spacecraft mass. Determining the long-term survivability of these materials before launch is critical for mission success. This presentation will describe an analysis performed on the outer layer of the passive thermal control blanket of the Hubble Space Telescope. This layer had degraded for unknown reasons during the mission, however ionizing radiation (IR) induced embrittlement was suspected. A methodology was developed which allowed direct comparison between the energy deposition of the natural environment and that of the laboratory generated environment. Commercial codes were used to predict the natural space IR environment model energy deposition in the material from both natural and laboratory IR sources, and design the most efficient test. Results were optimized for total and local energy deposition with an iterative spreadsheet. This method has been used successfully for several laboratory tests at the Marshall Space Flight Center. The study showed that the natural space IR environment, by itself, did not cause the premature degradation observed in the thermal blanket.
Modeling natural space ionizing radiation effects on external materials
NASA Astrophysics Data System (ADS)
Altstatt, Richard L.; Edwards, David L.
2000-10-01
Predicting the effective life of materials for space applications has become increasingly critical with the drive to reduce mission cost. Programs have considered many solutions to reduce launch costs including novel, low mass materials and thin thermal blankets to reduce spacecraft mass. Determining the long-term survivability of these materials before launch is critical for mission success. This presentation will describe an analysis performed on the outer layer of the passive thermal control blanket of the Hubble Space Telescope. This layer had degraded for unknown reasons during the mission, however ionizing radiation (IR) induced embrittlement was suspected. A methodology was developed which allowed direct comparison between the energy deposition of the natural environment and that of the laboratory generated environment. Commercial codes were used to predict the natural space IR environment, model energy deposition in the material from both natural and laboratory IR sources, and design the most efficient test. Results were optimized for total and local energy deposition with an iterative spreadsheet. This method has been used successfully for several laboratory tests at the Marshall Space Flight Center. The study showed that the natural space IR environment, by itself, did not cause the premature degradation observed in the thermal blanket.
Braune, S; Sperling, C; Maitz, M F; Steinseifer, U; Clauser, J; Hiebl, B; Krajewski, S; Wendel, H P; Jung, F
2017-10-01
The regulatory agencies provide recommendations rather than protocols or standard operation procedures for the hemocompatibility evaluation of novel materials e.g. for cardiovascular applications. Thus, there is a lack of specifications with regard to test setups and procedures. As a consequence, laboratories worldwide perform in vitro assays under substantially different test conditions, so that inter-laboratory and inter-study comparisons are impossible. Here, we report about a prospective, randomized and double-blind multicenter trial which demonstrates that standardization of in vitro test protocols allows a reproducible assessment of platelet adhesion and activation from fresh human platelet rich plasma as possible indicators of the thrombogenicity of cardiovascular implants. Standardization of the reported static in vitro setup resulted in a laboratory independent scoring of the following materials: poly(dimethyl siloxane) (PDMS), poly(ethylene terephthalate) (PET) and poly(tetrafluoro ethylene) (PTFE). The results of this in vitro study provide evidence that inter-laboratory and inter-study comparisons can be achieved for the evaluation of the adhesion and activation of platelets on blood-contacting biomaterials by stringent standardization of test protocols. Copyright © 2017 Elsevier B.V. All rights reserved.
Experimental assessment of aggregate surfacing materials.
DOT National Transportation Integrated Search
2007-06-30
"An extensive suite of geotechnical laboratory tests were conducted to quantify differences in : engineering properties of three crushed aggregates commonly used on Montana highway projects. The : material types are identified in the Montana Suppleme...
Recent advances in materials toxicology
NASA Technical Reports Server (NTRS)
Russo, D. M.
1979-01-01
An overview of the fire toxicology program, its principal objectives and approach, is outlined. The laboratory methods of assessing pyrolysis product toxicity for two experiments are presented. The two experiments are: a comparison of test end points; and an evaluation of operant techniques. A third experiment is outlined for a comparison of full-scale and laboratory toxicity tests, with the purpose of determining animal survivability in full-scale tests. Future research plans are also outlined.
Cryogenic insulation standard data and methodologies
NASA Astrophysics Data System (ADS)
Demko, J. A.; Fesmire, J. E.; Johnson, W. L.; Swanger, A. M.
2014-01-01
Although some standards exist for thermal insulation, few address the sub-ambient temperature range and cold-side temperatures below 100 K. Standards for cryogenic insulation systems require cryostat testing and data analysis that will allow the development of the tools needed by design engineers and thermal analysts for the design of practical cryogenic systems. Thus, this critically important information can provide reliable data and methodologies for industrial efficiency and energy conservation. Two Task Groups have been established in the area of cryogenic insulation systems Under ASTM International's Committee C16 on Thermal Insulation. These are WK29609 - New Standard for Thermal Performance Testing of Cryogenic Insulation Systems and WK29608 - Standard Practice for Multilayer Insulation in Cryogenic Service. The Cryogenics Test Laboratory of NASA Kennedy Space Center and the Thermal Energy Laboratory of LeTourneau University are conducting Inter-Laboratory Study (ILS) of selected insulation materials. Each lab carries out the measurements of thermal properties of these materials using identical flat-plate boil-off calorimeter instruments. Parallel testing will provide the comparisons necessary to validate the measurements and methodologies. Here we discuss test methods, some initial data in relation to the experimental approach, and the manner reporting the thermal performance data. This initial study of insulation materials for sub-ambient temperature applications is aimed at paving the way for further ILS comparative efforts that will produce standard data sets for several commercial materials. Discrepancies found between measurements will be used to improve the testing and data reduction techniques being developed as part of the future ASTM International standards.
MW Spallation Neutron Sources for Fusion Materials Testing
Dr. Donald Rej
2018-04-18
Dr. Donald Rej of Los Alamos National Laboratory presents an overview of issues, needs, and performance gaps related to materials testing and how they are being addressed at their facility. Current projects such as the Los Alamos Neutron Science Center (LANSCE) and Matter-Radiation Interactions in Extremes (MaRIE) are also discussed.
42 CFR 493.1252 - Standard: Test systems, equipment, instruments, reagents, materials, and supplies.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 5 2014-10-01 2014-10-01 false Standard: Test systems, equipment, instruments, reagents, materials, and supplies. 493.1252 Section 493.1252 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Quality System for Nonwaived...
Preliminary Validation of Composite Material Constitutive Characterization
John G. Michopoulos; Athanasios lliopoulos; John C. Hermanson; Adrian C. Orifici; Rodney S. Thomson
2012-01-01
This paper is describing the preliminary results of an effort to validate a methodology developed for composite material constitutive characterization. This methodology involves using massive amounts of data produced from multiaxially tested coupons via a 6-DoF robotic system called NRL66.3 developed at the Naval Research Laboratory. The testing is followed by...
ETR CRITICAL FACILITY (ETRCF), TRA654. SOUTH SIDE. CAMERA FACING NORTH ...
ETR CRITICAL FACILITY (ETR-CF), TRA-654. SOUTH SIDE. CAMERA FACING NORTH AND ROLL-UP DOOR. ORIGINAL SIDING HAS BEEN REPLACED WITH STUCCO-LIKE MATERIAL. INL NEGATIVE NO. HD46-40-1. Mike Crane, Photographer, 4/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
What LDEF means for development and testing of materials
NASA Technical Reports Server (NTRS)
Whitaker, Ann F.; Stuckey, Wayne K.; Stein, Bland A.
1993-01-01
The Long Duration Exposure Facility (LDEF) served as the ultimate laboratory to provide combined space environmental effects on materials. The LDEF structure and its 57 experiments contained an estimated 12,000 to 14,000 specimens of materials and materials processes. It not only provided information about the resistance of these materials to the space environment but gives us direction into future needs for spacecraft materials development and testing. This paper provides an overview of the materials effects observed on the satellite and suggests recommendations for the future work in space-qualified materials development and space environmental simulation.
Gargis, Amy S; Kalman, Lisa; Lubin, Ira M
2016-12-01
Clinical microbiology and public health laboratories are beginning to utilize next-generation sequencing (NGS) for a range of applications. This technology has the potential to transform the field by providing approaches that will complement, or even replace, many conventional laboratory tests. While the benefits of NGS are significant, the complexities of these assays require an evolving set of standards to ensure testing quality. Regulatory and accreditation requirements, professional guidelines, and best practices that help ensure the quality of NGS-based tests are emerging. This review highlights currently available standards and guidelines for the implementation of NGS in the clinical and public health laboratory setting, and it includes considerations for NGS test validation, quality control procedures, proficiency testing, and reference materials. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Galvín, Adela P; Ayuso, Jesús; Barbudo, Auxi; Cabrera, Manuel; López-Uceda, Antonio; Rosales, Julia
2017-12-27
In general terms, plant managers of sites producing construction wastes assess materials according to concise, legally recommended leaching tests that do not consider the compaction stage of the materials when they are applied on-site. Thus, the tests do not account for the real on-site physical conditions of the recycled aggregates used in civil works (e.g., roads or embankments). This leads to errors in estimating the pollutant potential of these materials. For that reason, in the present research, an experimental procedure is designed as a leaching test for construction materials under compaction. The aim of this laboratory test (designed specifically for the granular materials used in civil engineering infrastructures) is to evaluate the release of pollutant elements when the recycled aggregate is tested at its commercial grain-size distribution and when the material is compacted under on-site conditions. Two recycled aggregates with different gypsum contents (0.95 and 2.57%) were used in this study. In addition to the designed leaching laboratory test, the conventional compliance leaching test and the Dutch percolation test were performed. The results of the new leaching method were compared with the conventional leaching test results. After analysis, the chromium and sulphate levels obtained from the newly designed test were lower than those obtained from the conventional leaching test, and these were considered more seriously pollutant elements. This result confirms that when the leaching behaviour is evaluated for construction aggregates without density alteration, crushing the aggregate and using only the finest fraction, as is done in the conventional test (which is an unrealistic situation for aggregates that are applied under on-site conditions), the leaching behaviour is not accurately assessed.
Laboratory Characterization of SAM-35 Concrete
2006-09-01
procedures given in American Society for Testing and Materials (ASTM) D 2216 (ASTM 2002e). Based on the appropriate values of posttest water content, wet...composition properties of the material. All of the mechanical property tests were conducted quasi -statically with axial strain rates on the order...nondestructive pulse-velocity measurements were performed on each specimen. The TXC tests exhibited a continuous increase in principal stress
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piepel, Gregory F.; Amidan, Brett G.; Krauter, Paula
2011-05-01
Two concerns were raised by the Government Accountability Office following the 2001 building contaminations via letters containing Bacillus anthracis (BA). These included the: 1) lack of validated sampling methods, and 2) need to use statistical sampling to quantify the confidence of no contamination when all samples have negative results. Critical to addressing these concerns is quantifying the false negative rate (FNR). The FNR may depend on the 1) method of contaminant deposition, 2) surface concentration of the contaminant, 3) surface material being sampled, 4) sample collection method, 5) sample storage/transportation conditions, 6) sample processing method, and 7) sample analytical method.more » A review of the literature found 17 laboratory studies that focused on swab, wipe, or vacuum samples collected from a variety of surface materials contaminated by BA or a surrogate, and used culture methods to determine the surface contaminant concentration. These studies quantified performance of the sampling and analysis methods in terms of recovery efficiency (RE) and not FNR (which left a major gap in available information). Quantifying the FNR under a variety of conditions is a key aspect of validating sample and analysis methods, and also for calculating the confidence in characterization or clearance decisions based on a statistical sampling plan. A laboratory study was planned to partially fill the gap in FNR results. This report documents the experimental design developed by Pacific Northwest National Laboratory and Sandia National Laboratories (SNL) for a sponge-wipe method. The testing was performed by SNL and is now completed. The study investigated the effects on key response variables from six surface materials contaminated with eight surface concentrations of a BA surrogate (Bacillus atrophaeus). The key response variables include measures of the contamination on test coupons of surface materials tested, contamination recovered from coupons by sponge-wipe samples, RE, and FNR. The experimental design involves 16 test runs, performed in two blocks of eight runs. Three surface materials (stainless steel, vinyl tile, and ceramic tile) were tested in the first block, while three other surface materials (plastic, painted wood paneling, and faux leather) were tested in the second block. The eight surface concentrations of the surrogate were randomly assigned to test runs within each block. Some of the concentrations were very low and presented challenges for deposition, sampling, and analysis. However, such tests are needed to investigate RE and FNR over the full range of concentrations of interest. In each run, there were 10 test coupons of each of the three surface materials. A positive control sample was generated at the same time as each test sample. The positive control results will be used to 1) calculate RE values for the wipe sampling and analysis method, and 2) fit RE- and FNR-concentration equations, for each of the six surface materials. Data analyses will support 1) estimating the FNR for each combination of contaminant concentration and surface material, 2) estimating the surface concentrations and their uncertainties of the contaminant for each combination of concentration and surface material, 3) estimating RE (%) and their uncertainties for each combination of contaminant concentration and surface material, 4) fitting FNR-concentration and RE-concentration equations for each of the six surface materials, 5) assessing goodness-of-fit of the equations, and 6) quantifying the uncertainty in FNR and RE predictions made with the fitted equations.« less
Composite Materials and Meta Materials for a New Approach to ITER ICRH Loads
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bottollier-Curtet, H.; Argouarch, A.; Vulliez, K.
Preliminary laboratory testing of ICRH antennas is a very useful step before their commissioning. Traditionally, pure water, salt water or baking soda water loads are used. These 'water' loads are convenient but strongly limited in terms of performance testing. We have started two feasibility studies for advanced ICRH loads made of ferroelectric ceramics (passive loads) and meta materials (active loads). Preliminary results are very encouraging.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-08
... laboratories obtain a certificate from the Secretary of Health and Human Services (the Secretary), before accepting materials derived from the human body for laboratory tests (42 U.S.C. 263a(b)). Laboratories that... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2009-N-0489...
Spray sealing: A breakthrough in integral fuel tank sealing technology
NASA Astrophysics Data System (ADS)
Richardson, Martin D.; Zadarnowski, J. H.
1989-11-01
In a continuing effort to increase readiness, a new approach to sealing integral fuel tanks is being developed. The technique seals potential leak sources by spraying elastomeric materials inside the tank cavity. Laboratory evaluations project an increase in aircraft supportability and reliability, an improved maintainability, decreasing acquisition and life cycle costs. Increased usable fuel volume and lower weight than conventional bladders improve performance. Concept feasibility was demonstrated on sub-scale aircraft fuel tanks. Materials were selected by testing sprayable elastomers in a fuel tank environment. Chemical stability, mechanical properties, and dynamic durability of the elastomer are being evaluated at the laboratory level and in sub-scale and full scale aircraft component fatigue tests. The self sealing capability of sprayable materials is also under development. Ballistic tests show an improved aircraft survivability, due in part to the elastomer's mechanical properties and its ability to damp vibrations. New application equipment, system removal, and repair methods are being investigated.
Materials Compatibility Testing in Concentrated Hydrogen Peroxide
NASA Technical Reports Server (NTRS)
Boxwell, R.; Bromley, G.; Mason, D.; Crockett, D.; Martinez, L.; McNeal, C.; Lyles, G. (Technical Monitor)
2000-01-01
Materials test methods from the 1960's have been used as a starting point in evaluating materials for today's space launch vehicles. These established test methods have been modified to incorporate today's analytical laboratory equipment. The Orbital test objective was to test a wide range of materials to incorporate the revolution in polymer and composite materials that has occurred since the 1960's. Testing is accomplished in 3 stages from rough screening to detailed analytical tests. Several interesting test observations have been made during this testing and are included in the paper. A summary of the set-up, test and evaluation of long-term storage sub-scale tanks is also included. This sub-scale tank test lasted for a 7-month duration prior to being stopped due to a polar boss material breakdown. Chemical evaluations of the hydrogen peroxide and residue left on the polar boss surface identify the material breakdown quite clearly. The paper concludes with recommendations for future testing and a specific effort underway within the industry to standardize the test methods used in evaluating materials.
Laboratory-scale bioremediation of oil-contaminated soil of Kuwait with soil amendment materials.
Cho, B H; Chino, H; Tsuji, H; Kunito, T; Nagaoka, K; Otsuka, S; Yamashita, K; Matsumoto, S; Oyaizu, H
1997-10-01
A huge amount of oil-contaminated soil remains unremediated in the Kuwait desert. The contaminated oil has the potentiality to cause pollution of underground water and to effect the health of people in the neighborhood. In this study, laboratory scale bioremediation experiments were carried out. Hyponex (Hyponex, Inc.) and bark manure were added as basic nutrients for microorganisms, and twelve kinds of materials (baked diatomite, microporous glass, coconut charcoal, an oil-decomposing bacterial mixture (Formula X from Oppenheimer, Inc.), and eight kinds of surfactants) were applied to accelerate the biodegradation of oil hydrocarbons. 15% to 33% of the contaminated oil was decomposed during 43 weeks' incubation. Among the materials tested, coconut charcoal enhanced the biodegradation. On the contrary, the addition of an oil-decomposing bacterial mixture impeded the biodegradation. The effects of the other materials were very slight. The toxicity of the biodegraded compounds was estimated by the Ames test and the tea pollen tube growth test. Both of the hydrophobic (dichloromethane extracts) and hydrophilic (methanol extracts) fractions showed a very slight toxicity in the Ames test. In the tea pollen tube growth test, the hydrophobic fraction was not toxic and enhanced the growth of pollen tubes.
NASA Astrophysics Data System (ADS)
Farkas, Orsolya; Szabados, György; Antal, Ákos; Török, Ákos
2015-04-01
The effect of particulate matter on construction materials have been studied under laboratory conditions. For testing the adverse effects of diesel soot and particulate matter on stone and concrete a small scale laboratory exposure chamber was constructed. Blocks of 9 different stone types and concrete was placed in the chamber and an exhaust pipe of diesel engine was diverted into the system. Tested stones included: porous limestone, cemented non-porous limestone, travertine, marble, rhyolite tuff, andesite and granite. The engine was operated for 10 hours and the produced particulate matter was diverted directly to the surface of the material specimens of 3 cm in diameter each. Working parameters of the engine were controlled; the composition of the exhaust gas, smoke value and temperature were continuously measured during the test. Test specimens were documented and analysed prior to exposure and after the exposure test. Parameters such colorimetric values, weight, surface properties, mineralogical compositions of the test specimens were recorded. The working temperature was in the order of 300°C-320°C. The gas concentration was in ppm as follows: 157 CO; 5.98 CO2, 34.3 THC; 463 NOx; 408 NO; 12.88 O2. Our tests have demonstrated that significant amount of particulate matter was deposited on construction materials even at a short period of time; however the exposure was very intense. It also indicates that that the interaction of particulate matter and aerosol compounds with construction materials in urban areas causes rapid decay and has an adverse effect not only on human health but also on built structures.
Test of the wire ageing induced by radiation for the CMS barrel muon chambers
NASA Astrophysics Data System (ADS)
Conti, E.; Gasparini, F.
2001-06-01
We have carried out laboratory tests to measure the ageing of a wire tube due to pollutants outgassed by various materials. The tested materials are those used in the barrel muon drift tubes of the CMS experiment at LHC. An X-ray gun irradiated the test tube to accelerate the ageing process. No ageing effect has been measured for a period equivalent to 10 years of operation at LHC.
Geoengineering characterization of welded tuffs from laboratory and field investigations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zimmerman, R.M.; Nimick, F.B.; Board, M.P.
1984-12-31
Welded tuff beneath Yucca Mountain adjacent to the Nevada Test Site (NTS) is being considered for development as a high-level radioactive waste repository by the Nevada Nuclear Waste Storage Investigations (NNWSI) Project. Because access into Yucca Mountain has been limited to borehole explorations, early geoengineering materials characterizations have been derived from laboratory tests on cores from Yucca Mountain and from laboratory and field tests on welded tuffs located in G-Tunnel on the NTS. G-Tunnel contains welded tuffs that have similar properties and stress states to those at Yucca Mountain and has been the location for in situ rock mechanics testing.more » The purpose of this paper is to summarize the geoengineering material property data obtained to date and to compare appropriate laboratory and field data from G-Tunnel to findings from Yucca Mountain. Geomechanical and thermal data are provided and are augmented by limited geological and hydrological data. A comparison of results of laboratory measurements on tuffs from Yucca Mountain and G-Tunnel indicates good agreement between the bulk densities, saturations, moduli of elasticity, Poisson`s ratios, and P-wave velocities. The G-Tunnel tuff has slightly lower thermal conductivity, tensile strength, compressive strength and slightly higher matrix permeability than does the welded tuff near the proposed repository horizon at Yucca Mountain. From a laboratory-to-field scaling perspective, the modulus of deformation shows the most sensitivity to field conditions because of the presence of the joints found in the field. 14 references, 1 table.« less
Geoengineering characterization of welded tuffs from laboratory and field investigations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zimmerman, R.M.; Nimick, F.B.; Board, M.P.
1984-12-31
Welded tuff beneath Yucca Mountain adjacent to the Nevada Test Site (NTS) is being considered for development as a high-level radioactive waste repository by the Nevada Nuclear Waste Storage Investigations (NNWSI) Project. Because access into Yucca Mountain has been limited to borehole explorations, early geoengineering materials characterizations have been derived from laboratory tests on cores from Yucca Mountain and from laboratory and field tests on welded tuffs located in G-Tunnel on the NTS. G-Tunnel contains welded tuffs that have similar properties and stress states to those at Yucca Mountain and has been the location for in situ rock mechanics testing.more » The purpose of this paper is to summarize the geoengineering material property data obtained to date and to compare appropriate laboratory and field data from G-Tunnel to findings from Yucca Mountain. Geomechanical and thermal data are provided and are augmented by limited geological and hydrological data. A comparison of results of laboratory measurements on tuffs from Yucca Mountain and G-Tunnel indicates good agreement between the bulk densities, saturations, moduli of elasticity, Poisson`s ratios, and P-wave velocities. The G-Tunnel tuff has slightly lower thermal conductivity, tensile strength, compressive strength and slightly higher matrix permeability than does the welded tuff near the proposed repository horizon at Yucca Mountain. From a laboratory-to-field scaling perspective, the modulus of deformation shows the most sensitivity to field conditions because of the presence of joints found in the field. 14 refs., 1 tab.« less
NASA Technical Reports Server (NTRS)
2008-01-01
The NASA Cryogenics Test Laboratory at Kennedy Space Center conducted long-term testing of SOFI materials under actual-use cryogenic conditions with Cryostat-4. The materials included in the testing were NCFI 24-124 (acreage foam), BX-265 (close-out foam, including intertank flange and bipod areas), and a potential alternate material, NCFI 27-68, (acreage foam with the flame retardant removed). Specimens of these materials were placed at two locations: a site that simulated aging (the Vehicle Assembly Building [VAB]) and a site that simulated weathering (the Atmospheric Exposure Test Site [beach site]). After aging/weathering intervals of 3, 6, and 12 months, the samples were retrieved and tested for their thermal performance under cryogenic vacuum conditions with test apparatus Cryostat-4.
Ground-Laboratory to In-Space Atomic Oxygen Correlation for the PEACE Polymers
NASA Astrophysics Data System (ADS)
Stambler, Arielle H.; Inoshita, Karen E.; Roberts, Lily M.; Barbagallo, Claire E.; de Groh, Kim K.; Banks, Bruce A.
2009-01-01
The Materials International Space Station Experiment 2 (MISSE 2) Polymer Erosion and Contamination Experiment (PEACE) polymers were exposed to the environment of low Earth orbit (LEO) for 3.95 years from 2001 to 2005. There were forty-one different PEACE polymers, which were flown on the exterior of the International Space Station (ISS) in order to determine their atomic oxygen erosion yields. In LEO, atomic oxygen is an environmental durability threat, particularly for long duration mission exposures. Although space flight experiments, such as the MISSE 2 PEACE experiment, are ideal for determining LEO environmental durability of spacecraft materials, ground-laboratory testing is often relied upon for durability evaluation and prediction. Unfortunately, significant differences exist between LEO atomic oxygen exposure and atomic oxygen exposure in ground-laboratory facilities. These differences include variations in species, energies, thermal exposures and radiation exposures, all of which may result in different reactions and erosion rates. In an effort to improve the accuracy of ground-based durability testing, ground-laboratory to in-space atomic oxygen correlation experiments have been conducted. In these tests, the atomic oxygen erosion yields of the PEACE polymers were determined relative to Kapton H using a radio-frequency (RF) plasma asher (operated on air). The asher erosion yields were compared to the MISSE 2 PEACE erosion yields to determine the correlation between erosion rates in the two environments. This paper provides a summary of the MISSE 2 PEACE experiment; it reviews the specific polymers tested as well as the techniques used to determine erosion yield in the asher, and it provides a correlation between the space and ground-laboratory erosion yield values. Using the PEACE polymers' asher to in-space erosion yield ratios will allow more accurate in-space materials performance predictions to be made based on plasma asher durability evaluation.
2018-03-30
ARL-TR-8335•MAR 2018 US Army Research Laboratory Influence of Test Section Geometry on theBlast Environment in an Explosively DrivenConical Shock...ARL-TR-8335•MAR 2018 US Army Research Laboratory Influence of Test Section Geometry on theBlast Environment in an Explosively DrivenConical Shock...Tube by Joel B Stewart Weapons and Materials Research Directorate, ARL Approved for public release; distribution is unlimited. REPORT DOCUMENTATION
ETR, TRA642. BASEMENT SPACE ALLOCATION FOR EXPERIMENTERS CA. 1966, SOUTHEAST ...
ETR, TRA-642. BASEMENT SPACE ALLOCATION FOR EXPERIMENTERS CA. 1966, SOUTHEAST QUADRANT OF FLOOR. WESTINGHOUSE ATOMIC POWER DIVISION (WAPD) AND BETTIS ATOMIC POWER LABORATORY (BAPL) CONSUME MOST OF THE QUADRANT. PHILLIPS PETROLEUM COMPANY ETR-E-2256, 12/1966. INL INDEX NO. 532-0642-00-706-021256, REV. F. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
LUNAR SAMPLES - APOLLO XI - MSC
1969-08-03
S69-40740 (July 1969) --- Dr. Ross Taylor (seated), Australian National University, and John Allen, Brown and Root-Northrop technician, review preliminary data from the optical emission spectrograph in the Spectrographic Laboratory of the Physical-Chemical Test Laboratory. Tests were being conducted on lunar surface material collected by astronauts Neil A. Armstrong and Edwin E. Aldrin Jr. during their lunar surface extravehicular activity on July 20, 1969.
Overview of Materials R&D at Oak Ridge National Laboratory
2010-08-23
Titanium - 6Al - 4V 970 1.5 Boron Carbide (B4C) 350-550 (Flexural) 3.0+ Longstanding Achievements in Ceramic Science and Development 23 Baseline...Powders Front and back of V50-tested vacuum- hot-pressed Ti- 6Al - 4V • Oak Ridge National Laboratory Is Collaborating with Industry to Develop...Present and future growth areas – Lightweight materials ( titanium , magnesium, aluminum, carbon fibers and composites) with superior properties
Espahangizi, Kijan
2015-09-01
Glass vessels such as flasks and test tubes play an ambiguous role in the historiography of modern laboratory research. In spite of the strong focus on the role of materiality in the last decades, the scientific glass vessel - while being symbolically omnipresent - has remained curiously neglected in regard to its materiality. The popular image or topos of the transparent, neutral, and quasi-immaterial glass container obstructs the view of the physico-chemical functionality of this constitutive inner boundary in modern laboratory environments and its material historicity. In order to understand how glass vessels were able to provide a stable epistemic containment of spatially enclosed experimental phenomena in the new laboratory ecologies emerging in the nineteenth and early twentieth century, I will focus on the history of the material standardization of laboratory glassware. I will follow the rise of a new awareness for measurement errors due to the chemical agency of experimental glass vessels, then I will sketch the emergence of a whole techno-scientific infrastructure for the improvement of glass container quality in late nineteenth-century Germany. In the last part of my argument, I will return to the laboratory by looking at the implementation of this glass reform that created a new oikos for the inner experimental milieus of modern laboratory research.
Scaling effects in direct shear tests
Orlando, A.D.; Hanes, D.M.; Shen, H.H.
2009-01-01
Laboratory experiments of the direct shear test were performed on spherical particles of different materials and diameters. Results of the bulk friction vs. non-dimensional shear displacement are presented as a function of the non-dimensional particle diameter. Simulations of the direct shear test were performed using the Discrete Element Method (DEM). The simulation results show Considerable differences with the physical experiments. Particle level material properties, such as the coefficients of static friction, restitution and rolling friction need to be known a priori in order to guarantee that the simulation results are an accurate representation of the physical phenomenon. Furthermore, laboratory results show a clear size dependency on the results, with smaller particles having a higher bulk friction than larger ones. ?? 2009 American Institute of Physics.
NASA Technical Reports Server (NTRS)
Nettles, A. T.; Tucker, D. S.; Patterson, W. J.; Franklin, S. W.; Gordon, G. H.; Hart, L.; Hodge, A. J.; Lance, D. G.; Russel, S. S.
1991-01-01
A test run was performed on IM6/3501-6 carbon-epoxy in which the material was processed, machined into specimens, and tested for damage tolerance capabilities. Nondestructive test data played a major role in this element of composite characterization. A time chart was produced showing the time the composite material spent within each Branch or Division in order to identify those areas which produce a long turnaround time. Instrumented drop weight testing was performed on the specimens with nondestructive evaluation being performed before and after the impacts. Destructive testing in the form of cross-sectional photomicrography and compression-after-impact testing were used. Results show that the processing and machining steps needed to be performed more rapidly if data on composite material is to be collected within a reasonable timeframe. The results of the damage tolerance testing showed that IM6/3501-6 is a brittle material that is very susceptible to impact damage.
Clinical performance of amalgam as predicted by physical property tests.
Gale, E N; Osborne, J W
1980-01-01
For a number of years, dentistry has relied upon laboratory data to select and to certify the materials to be used in restorations. The data obtained from laboratory studies are used as criteria for clinical performance and also for sales promotion.
Seelye, James G.; Mac, Michael J.
1984-01-01
A literature review of sediment bioassessment was conducted as the first step in the development of a more standardized and ecologically sound test procedure for evaluating sediment quality. Based on the review, the authors concluded that 1) a standardized laboratory bioassessment test should consist of flowthrough exposure of at least 10 days duration using more than one aquatic organism including at least an infaunal benthic invertebrate and a fish species. 2) Before adoption of a laboratory sediment bioassessment procedure, the laboratory results should be evaluated by comparison with field conditions. 3) Most current sediment bioassessment regulatory tests measure acute toxicity or bioaccumulation. Development of tests to evaluate chronic, sublethal effects is needed.
NASA Astrophysics Data System (ADS)
Lamberty, Andrée; Franks, Katrin; Braun, Adelina; Kestens, Vikram; Roebben, Gert; Linsinger, Thomas P. J.
2011-12-01
The Institute for Reference Materials and Measurements has organised an interlaboratory comparison (ILC) to allow the participating laboratories to demonstrate their proficiency in particle size and zeta potential measurements on monomodal aqueous suspensions of silica nanoparticles in the 10-100 nm size range. The main goal of this ILC was to identify competent collaborators for the production of certified nanoparticle reference materials. 38 laboratories from four different continents participated in the ILC with different methods for particle sizing and determination of zeta potential. Most of the laboratories submitted particle size results obtained with centrifugal liquid sedimentation (CLS), dynamic light scattering (DLS) or electron microscopy (EM), or zeta potential values obtained via electrophoretic light scattering (ELS). The results of the laboratories were evaluated using method-specific z scores, calculated on the basis of consensus values from the ILC. For CLS (13 results) and EM (13 results), all reported values were within the ±2 | z| interval. For DLS, 25 of the 27 results reported were within the ±2 | z| interval, the two other results were within the ±3 | z| interval. The standard deviations of the corresponding laboratory mean values varied between 3.7 and 6.5%, which demonstrates satisfactory interlaboratory comparability of CLS, DLS and EM particle size values. From the received test reports, a large discrepancy was observed in terms of the laboratory's quality assurance systems, which are equally important for the selection of collaborators in reference material certification projects. Only a minority of the participating laboratories is aware of all the items that are mandatory in test reports compliant to ISO/IEC 17025 (ISO General requirements for the competence of testing and calibration laboratories. International Organisation for Standardization, Geneva, 2005b). The absence of measurement uncertainty values in the reports, for example, hindered the calculation of zeta scores.
Screening materials for smoke evolution
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Cumming, H. J.; Machado, A. M.
1978-01-01
The density of smoke produced by burning or smoldering materials is a factor that affects the ability of occupants to escape from a burning structure and the effectiveness of firefighters. Accordingly, considerable effort is being spent on developing materials that minimize the amount of smoke without impairing their performance characteristics. In the present paper, laboratory tests on such materials are described and evaluated. It is seen that the National Bureau of Standards smoke test and the Ohio State University release-rate test are the most promising for screening materials for smoke evolution. It is shown that, for plastics, smoke obscuration is a more realistic concern than smoke toxicity.
Kalman, Lisa; Tarleton, Jack; Hitch, Monica; Hegde, Madhuri; Hjelm, Nick; Berry-Kravis, Elizabeth; Zhou, Lili; Hilbert, James E; Luebbe, Elizabeth A; Moxley, Richard T; Toji, Lorraine
2013-07-01
Myotonic dystrophy type 1 (DM1) is caused by expansion of a CTG triplet repeat in the 3' untranslated region of the DMPK gene that encodes a serine-threonine kinase. Patients with larger repeats tend to have a more severe phenotype. Clinical laboratories require reference and quality control materials for DM1 diagnostic and carrier genetic testing. Well-characterized reference materials are not available. To address this need, the Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the genetic testing community, the National Registry of Myotonic Dystrophy and Facioscapulohumeral Muscular Dystrophy Patients and Family Members, and the Coriell Cell Repositories, has established and characterized cell lines from patients with DM1 to create a reference material panel. The CTG repeats in genomic DNA samples from 10 DM1 cell lines were characterized in three clinical genetic testing laboratories using PCR and Southern blot analysis. DMPK alleles in the samples cover four of five DM1 clinical categories: normal (5 to 34 repeats), mild (50 to 100 repeats), classical (101 to 1000 repeats), and congenital (>1000 repeats). We did not identify or establish Coriell cell lines in the premutation range (35 to 49 repeats). These samples are publicly available for quality control, proficiency testing, test development, and research and should help improve the accuracy of DM1 testing. Copyright © 2013 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.
Virological diagnosis of Ebolavirus infection.
Smith, D W; Rawlinson, W D; Kok, J; Dwyer, D E; Catton, M
2015-08-01
Ebolaviruses, and the other viral causes of haemorrhagic fevers (VHF) have always posed special problems for diagnostic laboratories. These arise from the rarity of human infections, minimal documented experience with test delivery and interpretation, the paucity of established commercial or in-house assays, the lack of clinical material for test development and validation, the high level containment required for handling live virus, the ongoing evolution of the viruses, and the high personal and public health requirements for accurate diagnosis. This article addresses the current situation and the ongoing challenges associated with delivering timely, high quality and safe testing within Australia for people exposed as part of the current major outbreak of Ebolavirus disease (EVD) in Western Africa. The members of the Public Health Laboratory Network have developed deliverable and reliable nucleic acid detection tests, and also have the laboratory capacity to handle the live viruses if necessary. However delivering and maintaining these services necessitates high levels of experience in developing and applying tests for exotic and emerging infections, strong national and international links and collaborations, ongoing monitoring and reassessment of test design and performance, innovative approaches to generation of positive control material, and a regular quality assurance program.
Virological diagnosis of Ebolavirus infection
Smith, D. W.; Rawlinson, W. D.; Kok, J.; Dwyer, D. E.; Catton, M.
2015-01-01
Summary Ebolaviruses, and the other viral causes of haemorrhagic fevers (VHF) have always posed special problems for diagnostic laboratories. These arise from the rarity of human infections, minimal documented experience with test delivery and interpretation, the paucity of established commercial or in-house assays, the lack of clinical material for test development and validation, the high level containment required for handling live virus, the ongoing evolution of the viruses, and the high personal and public health requirements for accurate diagnosis. This article addresses the current situation and the ongoing challenges associated with delivering timely, high quality and safe testing within Australia for people exposed as part of the current major outbreak of Ebolavirus disease (EVD) in Western Africa. The members of the Public Health Laboratory Network have developed deliverable and reliable nucleic acid detection tests, and also have the laboratory capacity to handle the live viruses if necessary. However delivering and maintaining these services necessitates high levels of experience in developing and applying tests for exotic and emerging infections, strong national and international links and collaborations, ongoing monitoring and reassessment of test design and performance, innovative approaches to generation of positive control material, and a regular quality assurance program. PMID:26126050
FAST CHOPPER BUILDING, TRA665. DETAIL SHOWS UPPER AND LOWER LEVEL ...
FAST CHOPPER BUILDING, TRA-665. DETAIL SHOWS UPPER AND LOWER LEVEL WALLS OF DIFFERING MATERIALS. NOTE DOORWAY TO MTR TO RIGHT OF CHOPPER BUILDING'S CLIPPED CORNER. CAMERA FACING WEST. INL NEGATIVE NO. HD42-1. Mike Crane, Photographer, 3/2004 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Pratt, Victoria M; Everts, Robin E; Aggarwal, Praful; Beyer, Brittany N; Broeckel, Ulrich; Epstein-Baak, Ruth; Hujsak, Paul; Kornreich, Ruth; Liao, Jun; Lorier, Rachel; Scott, Stuart A; Smith, Chingying Huang; Toji, Lorraine H; Turner, Amy; Kalman, Lisa V
2016-01-01
Pharmacogenetic testing is increasingly available from clinical laboratories. However, only a limited number of quality control and other reference materials are currently available to support clinical testing. To address this need, the Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the pharmacogenetic testing community and the Coriell Cell Repositories, has characterized 137 genomic DNA samples for 28 genes commonly genotyped by pharmacogenetic testing assays (CYP1A1, CYP1A2, CYP2A6, CYP2B6, CYP2C8, CYP2C9, CYP2C19, CYP2D6, CYP2E1, CYP3A4, CYP3A5, CYP4F2, DPYD, GSTM1, GSTP1, GSTT1, NAT1, NAT2, SLC15A2, SLC22A2, SLCO1B1, SLCO2B1, TPMT, UGT1A1, UGT2B7, UGT2B15, UGT2B17, and VKORC1). One hundred thirty-seven Coriell cell lines were selected based on ethnic diversity and partial genotype characterization from earlier testing. DNA samples were coded and distributed to volunteer testing laboratories for targeted genotyping using a number of commercially available and laboratory developed tests. Through consensus verification, we confirmed the presence of at least 108 variant pharmacogenetic alleles. These samples are also being characterized by other pharmacogenetic assays, including next-generation sequencing, which will be reported separately. Genotyping results were consistent among laboratories, with most differences in allele assignments attributed to assay design and variability in reported allele nomenclature, particularly for CYP2D6, UGT1A1, and VKORC1. These publicly available samples will help ensure the accuracy of pharmacogenetic testing. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Jimbert, P.; Iturrondobeitia, M.; Ibarretxe, J.; Fernandez-Martinez, R.
2015-03-01
When talking about trybology, the election of the laboratory experiment type is a common problem of discussion. Laboratory wear methods are not designed to exactly reproduce the real working conditions of the analyzed part itself but serve to engineers and researcher to extrapolate the laboratory results to the real application. In order to shed some light on this issue, two wear tests have been analyzed following an ASTM standard and using the same experimental parameters and testing pair-materials in order to be able to make a comparison: Pin-on-Disk (PoD) against Ball-on-Disk (BoD). Three different tool steel have been analyzed in this study, AISI D2, AISI A8 and AISI H13, used to produce metal cutting shears. Metal on metal dry sliding tests were designed in order to reproduce the tool working conditions. These three materials were cryogenically treated and compared against no cryogenically treated ones to measure the improvement on their wear resistance due to cryogenic treatment. Finally, the wear rates obtained with both laboratory tests were compared against some real production metal cutting tools wear data. Results revealed an improvement of the wear resistance for cryo-treated samples of around 20% with the BoD test and around 6% with the PoD test. Real production tools wear was calculated for one of the tool steels and for two different applications. The improvement was approximately the one revealed by the BoD test. So, for the studied case, the BoD laboratory test gives more realistic prediction of real tool life improvement due to the cryogenic treatment.
Alumina Based 500 C Electronic Packaging Systems and Future Development
NASA Technical Reports Server (NTRS)
Chen, Liang-Yu
2012-01-01
NASA space and aeronautical missions for probing the inner solar planets as well as for in situ monitoring and control of next-generation aeronautical engines require high-temperature environment operable sensors and electronics. A 96% aluminum oxide and Au thick-film metallization based packaging system including chip-level packages, printed circuit board, and edge-connector is in development for high temperature SiC electronics. An electronic packaging system based on this material system was successfully tested and demonstrated with SiC electronics at 500 C for over 10,000 hours in laboratory conditions previously. In addition to the tests in laboratory environments, this packaging system has more recently been tested with a SiC junction field effect transistor (JFET) on low earth orbit through the NASA Materials on the International Space Station Experiment 7 (MISSE7). A SiC JFET with a packaging system composed of a 96% alumina chip-level package and an alumina printed circuit board mounted on a data acquisition circuit board was launched as a part of the MISSE7 suite to International Space Station via a Shuttle mission and tested on the orbit for eighteen months. A summary of results of tests in both laboratory and space environments will be presented. The future development of alumina based high temperature packaging using co-fired material systems for improved performance at high temperature and more feasible mass production will also be discussed.
Microfermentation Test For Identification Of Yeast
NASA Technical Reports Server (NTRS)
Pierson, D. L.; Mishra, S. K.; Molina, Thomas C.
1995-01-01
Microfermentation test developed as supplementary method for use in identifying yeasts, especially in clinical and environmental studies. In comparison with traditional fermentation tests, simpler and easier, and requiries less equipment, material, and laboratory space. Results obtained in days instead of weeks.
29 CFR 1910.7 - Definition and requirements for a nationally recognized testing laboratory.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., written testing procedures, and calibration and quality control programs) to perform: (i) Testing and... test standards; or (ii) Experimental testing and examining of equipment and materials for workplace..., labeled, or accepted, the following controls or services: (i) Implements control procedures for...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piepel, Gregory F.; Amidan, Brett G.; Krauter, Paula
2010-12-16
Two concerns were raised by the Government Accountability Office following the 2001 building contaminations via letters containing Bacillus anthracis (BA). These included the: 1) lack of validated sampling methods, and 2) need to use statistical sampling to quantify the confidence of no contamination when all samples have negative results. Critical to addressing these concerns is quantifying the probability of correct detection (PCD) (or equivalently the false negative rate FNR = 1 - PCD). The PCD/FNR may depend on the 1) method of contaminant deposition, 2) surface concentration of the contaminant, 3) surface material being sampled, 4) sample collection method, 5)more » sample storage/transportation conditions, 6) sample processing method, and 7) sample analytical method. A review of the literature found 17 laboratory studies that focused on swab, wipe, or vacuum samples collected from a variety of surface materials contaminated by BA or a surrogate, and used culture methods to determine the surface contaminant concentration. These studies quantified performance of the sampling and analysis methods in terms of recovery efficiency (RE) and not PCD/FNR (which left a major gap in available information). Quantifying the PCD/FNR under a variety of conditions is a key aspect of validating sample and analysis methods, and also for calculating the confidence in characterization or clearance decisions based on a statistical sampling plan. A laboratory study was planned to partially fill the gap in PCD/FNR results. This report documents the experimental design developed by Pacific Northwest National Laboratory and Sandia National Laboratories (SNL) for a sponge-wipe method. The study will investigate the effects on key response variables from six surface materials contaminated with eight surface concentrations of a BA surrogate (Bacillus atrophaeus). The key response variables include measures of the contamination on test coupons of surface materials tested, contamination recovered from coupons by sponge-wipe samples, RE, and PCD/FNR. The experimental design involves 16 test runs, to be performed in two blocks of eight runs. Three surface materials (stainless steel, vinyl tile, and ceramic tile) were tested in the first block, while three other surface materials (plastic, painted wood paneling, and faux leather) will be tested in the second block. The eight surface concentrations of the surrogate were randomly assigned to test runs within each block. Some of the concentrations will be very low and may present challenges for deposition, sampling, and analysis. However, such tests are needed to investigate RE and PCD/FNR over the full range of concentrations of interest. In each run, there will be 10 test coupons of each of the three surface materials. A positive control sample will be generated prior to each test sample. The positive control results will be used to 1) calculate RE values for the wipe sampling and analysis method, and 2) fit RE- and PCD-concentration equations, for each of the six surface materials. Data analyses will support 1) estimating the PCD for each combination of contaminant concentration and surface material, 2) estimating the surface concentrations and their uncertainties of the contaminant for each combination of concentration and surface material, 3) estimating RE (%) and their uncertainties for each combination of contaminant concentration and surface material, 4) fitting PCD-concentration and RE-concentration equations for each of the six surface materials, 5) assessing goodness-of-fit of the equations, and 6) quantifying the uncertainty in PCD and RE predictions made with the fitted equations.« less
Blanchard, P C
2006-01-01
The air transportation of infectious materials is regulated by international air transport associations and based on United Nations Model regulations which have become more practical in addressing animal disease agents. However, individual countries' import and interstate requirements determine what materials can be imported and transported, and this approval process can be long, resulting in delays in organism confirmation, use of international OIE and other reference laboratories, and acquisition of reference materials, proficiency test panels, and reagents for performing necessary testing. Delays can be prevented for permits that are required for the routine work performed by a laboratory through the use of comprehensive and annually renewed permits. This process, however, does not address new and exotic agents where time is critical to an effective emergency response. This paper suggests actions by both the OIE and regulatory authorities which can assist in streamlining and expediting the permit process.
Shipboard Tests of Halon 1301 Test Gas Simulants
1990-08-22
Halon 1301 Test Gas Simulants," Memo Report, Naval Research Laboratory, Washington, DC, 1989. 8. Air Products and Chemicals , Inc ., "SF6 , An... Products and Chemicals , Inc ., "Specialty Gas Material Safety Data Sheet, Sulfur Hexafluoride " Air Products and Chemicals, Specialty Gas Department...34 Washington, DC, 1978. 11. N.I. Sax, Dangerous Properties of Industrial Materials, Sixth Edition, Van Nostrand Reinhold Company, New York, NY, 1984. 12. Air
Interpretation of standard leaching test BS EN 12457-2: is your sample hazardous or inert?
Zandi, Mohammad; Russell, Nigel V; Edyvean, Robert G J; Hand, Russell J; Ward, Philip
2007-12-01
A slag sample from a lead refiner has been obtained and given to two analytical laboratories to determine the release of trace elements from the sample according to BS EN 12457-2. Samples analysed by one laboratory passed waste acceptance criteria, leading it to be classified as an inert material; samples of the same material analysed by the other laboratory failed waste acceptance criteria and were classified as hazardous. It was found that the sample preparation procedure is the critical step in the leaching analysis and that the effects of particle size on leachability should be taken into account when using this standard. The purpose of this paper is to open a debate on designing a better defined standard leaching test and making current waste acceptance criteria more flexible.
2011-04-01
thus they should only be used when experienced operators have been trained on using the material with the mixer. ABC Cement was suited for various... autogenous shrinkage, all of which occur during hydration. Shrinkage potential is important because repair materials that shrink excessively are more
Homogeneity study of a corn flour laboratory reference material candidate for inorganic analysis.
Dos Santos, Ana Maria Pinto; Dos Santos, Liz Oliveira; Brandao, Geovani Cardoso; Leao, Danilo Junqueira; Bernedo, Alfredo Victor Bellido; Lopes, Ricardo Tadeu; Lemos, Valfredo Azevedo
2015-07-01
In this work, a homogeneity study of a corn flour reference material candidate for inorganic analysis is presented. Seven kilograms of corn flour were used to prepare the material, which was distributed among 100 bottles. The elements Ca, K, Mg, P, Zn, Cu, Fe, Mn and Mo were quantified by inductively coupled plasma optical emission spectrometry (ICP OES) after acid digestion procedure. The method accuracy was confirmed by analyzing the rice flour certified reference material, NIST 1568a. All results were evaluated by analysis of variance (ANOVA) and principal component analysis (PCA). In the study, a sample mass of 400mg was established as the minimum mass required for analysis, according to the PCA. The between-bottle test was performed by analyzing 9 bottles of the material. Subsamples of a single bottle were analyzed for the within-bottle test. No significant differences were observed for the results obtained through the application of both statistical methods. This fact demonstrates that the material is homogeneous for use as a laboratory reference material. Copyright © 2015 Elsevier Ltd. All rights reserved.
A mobile concrete laboratory to support quality concrete, technology transfer, and training.
DOT National Transportation Integrated Search
2016-07-01
This report is a summary of work performed by the Mobile Infrastructure Materials Testing Laboratory (MIMTL) as a part of the Joint : Transportation Research Program (JTRP) through SPR-3858. The development of the MIMTL began in February of 2014 and ...
Constitutive Soil Properties for Cuddeback Lake, California and Carson Sink, Nevada
NASA Technical Reports Server (NTRS)
Thomas, Michael A.; Chitty, Daniel E.; Gildea, Martin L.; T'Kindt, Casey M.
2008-01-01
Accurate soil models are required for numerical simulations of land landings for the Orion Crew Exploration Vehicle. This report provides constitutive material modeling properties for four soil models from two dry lakebeds in the western United States. The four soil models are based on mechanical and compressive behavior observed during geotechnical laboratory testing of remolded soil samples from the lakebeds. The test specimens were reconstituted to measured in situ density and moisture content. Tests included: triaxial compression, hydrostatic compression, and uniaxial strain. A fit to the triaxial test results defines the strength envelope. Hydrostatic and uniaxial tests define the compressibility. The constitutive properties are presented in the format of LS-DYNA Material Model 5: Soil and Foam. However, the laboratory test data provided can be used to construct other material models. The four soil models are intended to be specific only to the two lakebeds discussed in the report. The Cuddeback A and B models represent the softest and hardest soils at Cuddeback Lake. The Carson Sink Wet and Dry models represent different seasonal conditions. It is possible to approximate other clay soils with these models, but the results would be unverified without geotechnical tests to confirm similar soil behavior.
Web-Based Testing Tools for Electrical Engineering Courses
2001-09-01
ideas of distance learning are based on forming “ virtual teams” [2]. Each team is equipped with the same software packages and share information via...using virtual laboratories where they can simulate a laboratory experience in a web-based environment. They can also control laboratory devices over...possible to create a set of virtual laboratories that allow students to interact with the learning material at the same time that the student is
Corrosion Performance of New Generation Aluminum-Lithium Alloys for Aerospace Applications
NASA Astrophysics Data System (ADS)
Moran, James P.; Bovard, Francine S.; Chrzan, James D.; Vandenburgh, Peter
Over the past several years, a new generation of aluminum-lithium alloys has been developed. These alloys are characterized by excellent strength, low density, and high modulus of elasticity and are therefore of interest for lightweight structural materials applications particularly for construction of current and future aircraft. These new alloys have also demonstrated significant improvements in corrosion resistance when compared with the legacy and incumbent alloys. This paper documents the superior corrosion resistance of the current commercial tempers of these materials and also discusses the corrosion performance as a function of the degree of artificial aging. Results from laboratory corrosion tests are compared with results from exposures in a seacoast atmosphere to assess the predictive capability of the laboratory tests. The correlations that have been developed between the laboratory tests and the seacoast exposures provide confidence that a set of available methods can provide an accurate assessment of the corrosion performance of this new generation of alloys.
Cryogenic Thermal Performance Testing of Bulk-Fill and Aerogel Insulation Materials
NASA Technical Reports Server (NTRS)
Scholtens, B. E.; Fesmire, J. E.; Sass, J. P.; Augustynowicz, S. D.; Heckle, K. W.
2007-01-01
The research testing and demonstration of new bulk-fill materials for cryogenic thermal insulation systems was performed by the Cryogenics Test Laboratory at NASA Kennedy Space Center. Thermal conductivity testing under actual-use cryogenic conditions is a key to understanding the total system performance encompassing engineering, economics, and materials factors. A number of bulk fill insulation materials, including aerogel beads, glass bubbles, and perlite powder, were tested using a new cylindrical cryostat. Boundary temperatures for the liquid nitrogen boil-off method were 293 K and 78 K. Tests were performed as a function of cold vacuum pressure from high vacuum to no vacuum conditions. Results are compared with other complementary test methods in the range of 300 K to 20 K. Various testing techniques are shown to be required to obtain a complete understanding of the operating performance of a material and to provide data for answers to design engineering questions.
Placencia, A M; Peeler, J T
1999-01-01
A collaborative study involving 11 laboratories was conducted to measure the microbial barrier effectiveness of porous medical packaging. Two randomly cut samples from each of 6 commercially available porous materials and one positive and one negative control were tested by one operator in each of 11 laboratories. Microbial barrier effectiveness was measured in terms of logarithm reduction value (LRV), which reflects the log10 microbial penetration of the material being tested. The logarithm of the final concentration is subtracted from that of the initial concentration to obtain the LRV. Thus the higher the LRV, the better the barrier. Repeatability standard deviations ranged from 6.42 to 16.40; reproducibility standard deviations ranged from 15.50 to 22.70. Materials B(53), C(50), D(CT), and E(45MF) differ significantly from the positive control. The microbial ranking of porous packaging materials (exposure chamber method), ASTM method, has been adopted First Action by AOAC INTERNATIONAL.
National and international veterinary reference laboratories for infectious diseases.
Edwards, S; Alexander, D
1998-08-01
Reference laboratories play an increasingly important role in the harmonisation of laboratory diagnostic tests and the standardisation of veterinary vaccines. This is particularly important in building confidence between international trading partners. The authors review aspects of the organisation, designation and support of reference laboratories for infectious diseases of animals and discuss the principal activities which such laboratories would normally perform. These activities include advice and consultancy, publications and communication, training, research, disease surveillance, maintenance of culture collections, evaluation of reference methods, preparation of reference materials and organisation of inter-laboratory comparisons.
Cryogenic Thermal Performance Testing of Bulk-Fill and Aerogel Insulation Materials
NASA Astrophysics Data System (ADS)
Scholtens, B. E.; Fesmire, J. E.; Sass, J. P.; Augustynowicz, S. D.; Heckle, K. W.
2008-03-01
Thermal conductivity testing under actual-use conditions is a key to understanding how cryogenic thermal insulation systems perform in regard to engineering, economics, and materials factors. The Cryogenics Test Laboratory at NASA's Kennedy Space Center tested a number of bulk-fill insulation materials, including aerogel beads, glass bubbles, and perlite powder, using a new cylindrical cryostat. Boundary temperatures for the liquid nitrogen boiloff method were 78 K and 293 K. Tests were performed as a function of cold vacuum pressure under conditions ranging from high vacuum to no vacuum. Results were compared with those from complementary test methods in the range of 20 K to 300 K. Various testing techniques are required to completely understand the operating performance of a material and to provide data for answers to design engineering questions.
From Laboratory Research to a Clinical Trial
Michels, Harold T.; Keevil, C. William; Salgado, Cassandra D.; Schmidt, Michael G.
2015-01-01
Objective: This is a translational science article that discusses copper alloys as antimicrobial environmental surfaces. Bacteria die when they come in contact with copper alloys in laboratory tests. Components made of copper alloys were also found to be efficacious in a clinical trial. Background: There are indications that bacteria found on frequently touched environmental surfaces play a role in infection transmission. Methods: In laboratory testing, copper alloy samples were inoculated with bacteria. In clinical trials, the amount of live bacteria on the surfaces of hospital components made of copper alloys, as well as those made from standard materials, was measured. Finally, infection rates were tracked in the hospital rooms with the copper components and compared to those found in the rooms containing the standard components. Results: Greater than a 99.9% reduction in live bacteria was realized in laboratory tests. In the clinical trials, an 83% reduction in bacteria was seen on the copper alloy components, when compared to the surfaces made from standard materials in the control rooms. Finally, the infection rates were found to be reduced by 58% in patient rooms with components made of copper, when compared to patients' rooms with components made of standard materials. Conclusions: Bacteria die on copper alloy surfaces in both the laboratory and the hospital rooms. Infection rates were lowered in those hospital rooms containing copper components. Thus, based on the presented information, the placement of copper alloy components, in the built environment, may have the potential to reduce not only hospital-acquired infections but also patient treatment costs. PMID:26163568
High-temperature acoustic test facilities and methods
NASA Astrophysics Data System (ADS)
Pearson, Jerome
1994-09-01
The Wright Laboratory is the Air Force center for air vehicles, responsible for developing advanced technology and incorporating it into new flight vehicles and for continuous technological improvement of operational air vehicles. Part of that responsibility is the problem of acoustic fatigue. With the advent of jet aircraft in the 1950's, acoustic fatigue of aircraft structure became a significant problem. In the 1960's the Wright Laboratory constructed the first large acoustic fatigue test facilities in the United States, and the laboratory has been a dominant factor in high-intensity acoustic testing since that time. This paper discusses some of the intense environments encountered by new and planned Air Force flight vehicles, and describes three new acoustic test facilities of the Wright Laboratory designed for testing structures in these dynamic environments. These new test facilities represent the state of the art in high-temperature, high-intensity acoustic testing and random fatigue testing. They will allow the laboratory scientists and engineers to test the new structures and materials required to withstand the severe environments of captive-carry missiles, augmented lift wings and flaps, exhaust structures of stealth aircraft, and hypersonic vehicle structures well into the twenty-first century.
LLNL small-scale static spark machine: static spark sensitivity test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Foltz, M F; Simpson, L R
1999-08-23
Small-scale safety testing of explosives and other energetic materials is done in order to determine their sensitivity to various stimuli, such as friction, static spark, and impact. Typically this testing is done to discover potential handling problems that may exist for either newly synthesized materials of unknown behavior, or materials that have been stored for long periods of time. This report describes the existing ''Static Spark Test Apparatus'' at Lawrence Livermore National Laboratory (LLNL), as well as the method used to evaluate the relative static spark sensitivity of energetic materials. The basic design, originally developed by the Picatinny Arsenal inmore » New Jersey, is discussed. The accumulated data for the materials tested to date is not included here, with the exception of specific examples that have yielded interesting or unusual results during the tests.« less
Wang, Jin-Sook; Kee, Mee-Kyung; Choi, Byeong-Sun; Kim, Chan-Wha; Kim, Hyon-Suk; Kim, Sung Soon
2012-01-01
The external quality assessment schemes (EQAS) organizer provides a suitable program to monitor and improve the quality of human immunodeficiency virus (HIV) testing laboratories with EQAS panels prepared under various conditions. The aim of the current study was to investigate the effects of human plasma samples on the EQAS results of HIV obtained from hospital-based clinical laboratories. From 2007 to 2009, HIV EQAS panels consisted of four to six samples that consisted of undiluted positive and negative samples and were provided to laboratories twice per year. Up until the first half EQAS in 2008, EQAS panel materials were obtained by converting acid citrate dextrose treated plasma to serum via chemical treatment with CaCl2. Beginning with the second EQAS in 2008, all materials were prepared without the defibrination process. Approximately 300 HIV clinical laboratories participated in this program. The overall performance of clinical laboratories was shown to be improved when using unrecalcified plasma panels compared with recalcified panels. Significant differences were observed in EIA analyses of plasma for both positive (p<0.001) and negative (p<0.001) samples between the recalcified and unrecalcified groups. Our finding suggested that defibrination status of EQAS panels might affect the results of anti-HIV EQAS of Korean HIV testing laboratories.
A new concept for stainless steels ranking upon the resistance to cavitation erosion
NASA Astrophysics Data System (ADS)
Bordeasu, I.; Popoviciu, M. O.; Salcianu, L. C.; Ghera, C.; Micu, L. M.; Badarau, R.; Iosif, A.; Pirvulescu, L. D.; Podoleanu, C. E.
2017-01-01
In present, the ranking of materials as their resistance to cavitation erosion is obtained by using laboratory tests finalized with the characteristic curves mean depth erosion against time MDE(t) and mean depth erosion rate against time MDER(t). In some previous papers, Bordeasu and co-workers give procedures to establish exponential equation representing the curves, with minimum scatter of the experimental obtained results. For a given material, both exponential equations MDE(t) and MDER(t) have the same values for the parameters of scale and for the shape one. For the ranking of materials is sometimes important to establish single figure. Till now in Timisoara Polytechnic University Cavitation Laboratory were used three such numbers: the stable value of the curve MDER(t), the resistance to cavitation erosion (Rcav ≡ 1/MDERstable) and the normalized cavitation resistance Rns which is the rate between vs = MDERstable for the analyzed material and vse= MDERse the mean depth erosion rate for the steel OH12NDL (Rns = vs/vse ). OH12NDL is a material used for manufacturing the blades of numerous Kaplan turbines in Romania for which both cavitation erosion laboratory tests and field measurements of cavitation erosions are available. In the present paper we recommend a new method for ranking the materials upon cavitation erosion resistance. This method uses the scale and shape parameters of the exponential equations which represents the characteristic cavitation erosion curves. Till now the method was applied only for stainless steels. The experimental results show that the scale parameter represents an excellent method for ranking the stainless steels. In the future this kind of ranking will be tested also for other materials especially for bronzes used for manufacturing ship propellers.
ELECTRICAL LINES ARRIVE FROM CENTRAL FACILITIES AREA, SOUTH OF MTR. ...
ELECTRICAL LINES ARRIVE FROM CENTRAL FACILITIES AREA, SOUTH OF MTR. EXCAVATION RUBBLE IN FOREGROUND. CONTRACTOR CRAFT SHOPS, CRANES, AND OTHER MATERIALS ON SITE. CAMERA FACES EAST, WITH LITTLE BUTTE AND MIDDLE BUTTE IN DISTANCE. INL NEGATIVE NO. 335. Unknown Photographer, 7/1/1950 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
John G. Michopoulos; John C. Hermanson; Athanasios Iliopoulos
2012-01-01
In this paper we are reporting on the first successful campaign of systematic, automated and massive multiaxial tests for composite material constitutive characterization. The 6 degrees of freedom system developed at the Naval Research Laboratory (NRL) called NRL66.3, was used for this task. This was the inaugural run that served as the validation of the...
Process material management in the Space Station environment
NASA Technical Reports Server (NTRS)
Perry, J. L.; Humphries, W. R.
1988-01-01
The Space Station will provide a unique facility for conducting material-processing and life-science experiments under microgravity conditions. These conditions place special requirements on the U.S. Laboratory for storing and transporting chemicals and process fluids, reclaiming water from selected experiments, treating and storing experiment wastes, and providing vacuum utilities. To meet these needs and provide a safe laboratory environment, the Process Material Management System (PMMS) is being developed. Preliminary design requirements and concepts related to the PMMS are addressed, and the MSFC PMMS breadboard test facility and a preliminary plan for validating the overall system design are discussed.
1982-03-01
meter 25 11.0 Microstructure by SEM 11.1 Introduction In order to correlate observed physical and mechanical properties in cured grout samples, a...studied at the two laboratories has proper physical properties , phase composi- tions, and microstructures for the materials used and ages covered...Scanning Electron Microscope Resolution Test Specimen ( Al -W) D. B. Ballard Research Material 100 SEM Resolution Test Specimen (AI-W)., is an alloy of
PROGRAM ASTEC (ADVANCED SOLAR TURBO ELECTRIC CONCEPT). PART 1. CANDIDATE MATERIALS LABORATORY TESTS
A space power system of the type envisioned by the ASTEC program requires the development of a lightweight solar collector of high reflectance...capable of withstanding the space environment for an extended period. A survey of the environment of interest for ASTEC purposes revealed 4 potential...developed by the solar-collector industry for use in the ASTEC program, and to test the effects of space environment on these materials. Of 6 material
NASA Technical Reports Server (NTRS)
Kerr, James R.; Haskins, James F.
1987-01-01
Advanced composites will play a key role in the development of the technology for the design and fabrication of future supersonic vehicles. However, incorporating the material into vehicle usage is contingent on accelerating the demonstration of service capacity and design technology. Because of the added material complexity and lack of extensive data, laboratory replication of the flight service will provide the most rapid method to document the airworthiness of advanced composite systems. Consequently, a laboratory program was conducted to determine the time-temperature-stress capabilities of several high temperature composites. Tests included were thermal aging, environmental aging, fatigue, creep, fracture, tensile, and real-time flight simulation exposure. The program had two phases. The first included all the material property determinations and aging and simulation exposures up through 10,000 hours. The second continued these tests up to 50,000 cumulative hours. This report presents the results of the Phase 1 baseline and 10,000-hr aging and flight simulation studies, the Phase 2 50,000-hr aging studies, and the Phase 2 flight simulation tests, some of which extended to almost 40,000 hours.
Coplen, T.B.; Qi, H.
2009-01-01
New isotope laboratories can achieve the goal of reporting the same isotopic composition within analytical uncertainty for the same material analysed decades apart by (1) writing their own acceptance testing procedures and putting them into their mass spectrometric or laser-based isotope-ratio equipment procurement contract, (2) requiring a manufacturer to demonstrate acceptable performance using all sample ports provided with the instrumentation, (3) for each medium to be analysed, prepare two local reference materials substantially different in isotopic composition to encompass the range in isotopic composition expected in the laboratory and calibrated them with isotopic reference materials available from the International Atomic Energy Agency (IAEA) or the US National Institute of Standards and Technology (NIST), (4) using the optimum storage containers (for water samples, sealing in glass ampoules that are sterilised after sealing is satisfactory), (5) interspersing among sample unknowns local laboratory isotopic reference materials daily (internationally distributed isotopic reference materials can be ordered at three-year intervals, and can be used for elemental analyser analyses and other analyses that consume less than 1 mg of material) - this process applies to H, C, N, O, and S isotope ratios, (6) calculating isotopic compositions of unknowns by normalising isotopic data to that of local reference materials, which have been calibrated to internationally distributed isotopic reference materials, (7) reporting results on scales normalised to internationally distributed isotopic reference materials (where they are available) and providing to sample submitters the isotopic compositions of internationally distributed isotopic reference materials of the same substance had they been analysed with unknowns, (8) providing an audit trail in the laboratory for analytical results - this trail commonly will be in electronic format and might include a laboratory information management system, (9) making at regular intervals a complete backup of laboratory analytical data (both of samples logged into the laboratory and of mass spectrometric analyses), being sure to store one copy of this backup offsite, and (10) participating in interlaboratory comparison exercises sponsored by the IAEA and other agencies at regular intervals. ?? Taylor & Francis.
Enhanced Verification Test Suite for Physics Simulation Codes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kamm, J R; Brock, J S; Brandon, S T
2008-10-10
This document discusses problems with which to augment, in quantity and in quality, the existing tri-laboratory suite of verification problems used by Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and Sandia National Laboratories (SNL). The purpose of verification analysis is demonstrate whether the numerical results of the discretization algorithms in physics and engineering simulation codes provide correct solutions of the corresponding continuum equations. The key points of this document are: (1) Verification deals with mathematical correctness of the numerical algorithms in a code, while validation deals with physical correctness of a simulation in a regime of interest.more » This document is about verification. (2) The current seven-problem Tri-Laboratory Verification Test Suite, which has been used for approximately five years at the DOE WP laboratories, is limited. (3) Both the methodology for and technology used in verification analysis have evolved and been improved since the original test suite was proposed. (4) The proposed test problems are in three basic areas: (a) Hydrodynamics; (b) Transport processes; and (c) Dynamic strength-of-materials. (5) For several of the proposed problems we provide a 'strong sense verification benchmark', consisting of (i) a clear mathematical statement of the problem with sufficient information to run a computer simulation, (ii) an explanation of how the code result and benchmark solution are to be evaluated, and (iii) a description of the acceptance criterion for simulation code results. (6) It is proposed that the set of verification test problems with which any particular code be evaluated include some of the problems described in this document. Analysis of the proposed verification test problems constitutes part of a necessary--but not sufficient--step that builds confidence in physics and engineering simulation codes. More complicated test cases, including physics models of greater sophistication or other physics regimes (e.g., energetic material response, magneto-hydrodynamics), would represent a scientifically desirable complement to the fundamental test cases discussed in this report. The authors believe that this document can be used to enhance the verification analyses undertaken at the DOE WP Laboratories and, thus, to improve the quality, credibility, and usefulness of the simulation codes that are analyzed with these problems.« less
Bronić, Ana; Herak, Desiree Coen; Margetić, Sandra; Milić, Marija
2017-01-01
Introduction The objective of this survey was to assess current policies and practice in haemostasis testing among both hospital and outpatient laboratories in Republic of Croatia. Materials and methods A questionnaire with seventy questions divided into nine sections was created in May 2015. Participants were asked about their practice related to test request form, sample collection, prothrombin time (PT) and activated partial thromboplastin time assays, other individual haemostasis assays, point-of-care testing (POCT), reporting of coagulation tests results and quality assurance of procedures, the personnel and other laboratory resources, as well as on issues related to education and implementation of additional coagulation assays in their laboratory. The survey was administered and data were collected between June and September 2015. Results A total survey response rate was 104/170 (61.2%). Most respondents were faced with incomplete information on prescribed therapy and diagnosis on the test request or inappropriate samples withdrawn on distant locations, but also do not have protocols for handling samples with high haematocrit values. Reporting of PT-INR and D-dimer results was different between laboratories. Although almost all laboratories developed a critical value reporting system, reporting a value to general practitioners is still a problem. Result on coagulation POCT testing showed that not all devices were supervised by laboratories, which is not in compliance with Croatian Chamber of Medical Biochemistry acts. Conclusion Obtained results highlighted areas that need improvement and different practice patterns in particular field of haemostasis testing among laboratories. A harmonization of the overall process of haemostasis testing at national level should be considered and undertaken. PMID:28392741
Hammond, M Elizabeth H; Barker, Peter; Taube, Sheila; Gutman, Steven
2003-06-01
A workshop was sponsored by the National Institute of Standards and Technology, the Cancer Diagnosis Program of the National Cancer Institute, the Food and Drug Administration, and the College of American Pathologists to address the need for a reference material for Her2 gene protein testing. It was agreed that such a standard was desirable and necessary to ensure the reliability of Her2 testing to qualify patients for trastuzumab therapy. Two standards consisting of well characterized cell lines will be produced, 1 that will be a National Institute of Standards and Technology-certifiable standard, and 1 that will be a commercially developed standard for use in all Her2 testing. It was also agreed that all Her2 testing must be performed on samples fixed only in 10% buffered formalin, as specified in the Food and Drug Administration-approved testing methods. Participants agreed to plan strategies to educate pathologists, clinicians, and laboratories about the need and use of such a standard. A National Committee for Clinical Laboratory Standards guideline for the use of the standard reference material will be created to facilitate this process.
Fedeli, Ligia G; Vidigal, Pedro G; Leite, Claudia Mendes; Castilhos, Cristina D; Pimentel, Robércia Anjos; Maniero, Viviane C; Mill, Jose Geraldo; Lotufo, Paulo A; Pereira, Alexandre C; Bensenor, Isabela M
2013-06-01
The ELSA (Estudo Longitudinal de Saúde do Adulto - Brazilian Longitudinal Study for Adult Health) is a multicenter cohort study which aims at the identification of risk factors associated with type 2 diabetes and cardiovascular diseases in the Brazilian population. The paper describes the strategies for the collection, processing, transportation, and quality control of blood and urine tests in the ELSA. The study decided to centralize the tests at one single laboratory. The processing of the samples was performed at the local laboratories, reducing the weight of the material to be transported, and diminishing the costs of transportation to the central laboratory at the Universidade de São Paulo Hospital. The study included tests for the evaluation of diabetes, insulin resistance, dyslipidemia, electrolyte abnormalities, thyroid hormones, uric acid, hepatic enzyme abnormalities, inflammation, and total blood cell count. In addition, leukocyte DNA, urine, plasma and serum samples were stored. The central laboratory performed approximately 375,000 tests.
Cuhra, Marek; Bøhn, Thomas; Cuhra, Petr
2017-01-01
Plastic laboratory materials are found to affect vital parameters of the waterflea Daphnia magna. The main responsible factor is defined as “newness” of the materials. Juvenile D. magna were raised individually in; a) new laboratory-standard 50 ml polypropylene tubes, and; b) identical tubes which had been washed and aerated for several weeks. Newness had significant effects on growth and fecundity of D. magna. New tubes caused delayed maturation, reduced reproduction and reduced growth when compared to washed and re-used tubes of the same commercial brand. The findings indicate that newness of tubes has inhibiting or toxic effects on D. magna. Often laboratory plastics are intended for single-use due to sterility demands. Newness might be an important confounding factor in research results and should not be disregarded. Disposable plastic utensils may come with a seemingly ignored cost and induce adverse effects in biological test-organisms and systems. The presented findings accentuate continued need for general awareness concerning confounding factors stemming from material laboratory environment. Based on the present findings the authors suggest that plastics intended for use in sensitive research may need to be washed and aerated prior to use. PMID:28425469
Dental Charting. Learning Activities, Unit Tests, Progress Chart, and Work Sheet.
ERIC Educational Resources Information Center
Texas Univ., Austin. Center for Occupational Curriculum Development.
These materials are part of a series dealing with skills and information needed by students in dental assisting. The individualized student materials are suitable for classroom, laboratory, or cooperative training programs. These student materials, designed to be used with the Dental Charting Student Manual, consist of learning activities, unit…
NASA Astrophysics Data System (ADS)
Hsu, Peter; Hust, Gary; Reynolds, John; Springer, Keo; Fried, Larry; Maienschein, Jon
2013-06-01
Incidents caused by fire and combat operations in battlefields can expose energetic materials to unexpected heat that may cause thermal explosion, structural damage and casualty. Some explosives may thermally explode at fairly low temperatures (<100 C) and the violence from thermal explosion may cause a significant damage. Thus it is important to understand the response of energetic materials to thermal insults. The One Dimensional Time to Explosion (ODTX) system at the Lawrence Livermore National Laboratory can measure times to explosion, threshold thermal explosion temperature, and determine kinetic parameters of energetic materials. Samples of different configurations (pressed part, powder, paste, and liquid) can be tested in the system. The ODTX testing can also provide useful data for assessing the thermal explosion violence of energetic materials. In this paper, we will present some recent ODTX experimental data and compare thermal explosion violence of different energetic materials. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.
Corona And Ultraviolet Equipment For Testing Materials
NASA Technical Reports Server (NTRS)
Laue, Eric G.
1993-01-01
Two assemblies of laboratory equipment developed for use in testing abilities of polymers, paints, and other materials to withstand ultraviolet radiation and charged particles. One is vacuum ultraviolet source built around commercial deuterium lamp. Other exposes specimen in partial vacuum to both ultraviolet radiation and brush corona discharge. Either or both assemblies used separately or together to simulate approximately combination of solar radiation and charged particles encountered by materials aboard spacecraft in orbit around Earth. Also used to provide rigorous environmental tests of materials exposed to artificial ultraviolet radiation and charged particles in industrial and scientific settings or to natural ultraviolet radiation and charged particles aboard aircraft at high altitudes.
45 CFR 304.20 - Availability and rate of Federal financial participation.
Code of Federal Regulations, 2014 CFR
2014-10-01
... development of evidence including the use of the polygraph and genetic tests; (C) Pre-trial discovery; (ii... regulations having the effect of law; (iii) Identifying competent laboratories that perform genetic tests as... transporting blood and other samples of genetic material, repeated testing when necessary, analysis of test...
45 CFR 304.20 - Availability and rate of Federal financial participation.
Code of Federal Regulations, 2012 CFR
2012-10-01
... development of evidence including the use of the polygraph and genetic tests; (C) Pre-trial discovery; (ii... regulations having the effect of law; (iii) Identifying competent laboratories that perform genetic tests as... transporting blood and other samples of genetic material, repeated testing when necessary, analysis of test...
45 CFR 304.20 - Availability and rate of Federal financial participation.
Code of Federal Regulations, 2011 CFR
2011-10-01
... development of evidence including the use of the polygraph and genetic tests; (C) Pre-trial discovery; (ii... regulations having the effect of law; (iii) Identifying competent laboratories that perform genetic tests as... transporting blood and other samples of genetic material, repeated testing when necessary, analysis of test...
40 CFR 60.533 - Compliance and certification.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., including the complete test report and, for all test runs: Raw data sheets, laboratory technician notes... each test run in a certification test series, two photographs of the fuel load: One before and one... of blower motors and the fan blade size. (3) Any change in the materials used for the following...
40 CFR 60.533 - Compliance and certification.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., including the complete test report and, for all test runs: Raw data sheets, laboratory technician notes... each test run in a certification test series, two photographs of the fuel load: One before and one... of blower motors and the fan blade size. (3) Any change in the materials used for the following...
40 CFR 60.533 - Compliance and certification.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., including the complete test report and, for all test runs: Raw data sheets, laboratory technician notes... each test run in a certification test series, two photographs of the fuel load: One before and one... of blower motors and the fan blade size. (3) Any change in the materials used for the following...
40 CFR 60.533 - Compliance and certification.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., including the complete test report and, for all test runs: Raw data sheets, laboratory technician notes... each test run in a certification test series, two photographs of the fuel load: One before and one... of blower motors and the fan blade size. (3) Any change in the materials used for the following...
40 CFR 60.533 - Compliance and certification.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., including the complete test report and, for all test runs: Raw data sheets, laboratory technician notes... each test run in a certification test series, two photographs of the fuel load: One before and one... of blower motors and the fan blade size. (3) Any change in the materials used for the following...
Tack, Véronique; Ligtenberg, Marjolijn J L; Tembuyser, Lien; Normanno, Nicola; Vander Borght, Sara; Han van Krieken, J; Dequeker, Elisabeth M C
2015-03-01
Regulations for the selection of patients with metastatic colorectal cancer for anti-EGFR treatment changed at the end of 2013. The set of mutations to be tested extended from KRAS codons 12 and 13 to KRAS and NRAS exons 2, 3, and 4. A European external quality assessment scheme monitored the performance of laboratories and evaluated the implementation of the new regulations. The 131 participating laboratories received 10 samples of formalin-fixed paraffin-embedded material, including RAS (exon 2, 3, 4) and BRAF mutations. Mock clinical data were provided for three cases. Using their routine methods, laboratories determined the genotypes and submitted three written reports. Assessors scored the results according to predefined evaluation criteria. Half of the participants (49.3%) had completely implemented the new test requirements (codons 12, 13, 59, 61, 117, and 146 of KRAS and NRAS), and 96 laboratories (73.3%) made no genotype mistakes. Correct nomenclature, according to the Human Genome Variation Society, was used by 82 laboratories (62.6%). Although regulations were effective for several months, many laboratories were not ready for full RAS testing in the context of anti-EGFR therapy. Nevertheless, in each participating country, there are laboratories that provide complete and correct testing. External quality assessments can be used to monitor implementation of new test regulations and to stimulate the laboratories to improve their testing procedures. Because the results of this program are available on the website of the European Society of Pathology, patients and clinicians can refer test samples to a reliable laboratory. ©AlphaMed Press.
Laboratory Resources Management in Manufacturing Systems Programs
ERIC Educational Resources Information Center
Obi, Samuel C.
2004-01-01
Most, if not all, industrial technology (IT) programs have laboratories or workshops. Often equipped with modern equipment, tools, materials, and measurement and test instruments, these facilities constitute a major investment for IT programs. Improper use or over use of program facilities may result in dirty lab equipment, lost or damaged tools,…
Akchata, Suman; Lavanya, K; Shivanand, Bhushan
2017-01-01
Decontamination of various working surfaces with sodium pertechnetate minor spillage is essential for maintaining good radiation safety practices as well as for regulatory compliance. To observe the influences of decontaminating agents and swipe materials on different type of surfaces used in nuclear medicine laboratory work area wet spilled with 99m-technetium (99mTc) sodium pertechnetate. Lab-simulated working surface materials. Experimental study design. Direct decontamination method on dust-free lab simulated new working surfaces [stainless steel, polyvinyl chloride (PVC), Perspex, resin] using four decontaminating agents [tap water, soap water (SW), Radiacwash, and spirit] with four different swipe material [cotton, tissue paper (TP), Whatman paper (WP), adsorbent sheet (AS)] was taken 10 samples (n = 10) for each group. Parametric test two-way analysis of variance is used with significance level of 0.005, was used to evaluate statistical differences between different group of decontaminating agent and swipe material, and the results are expressed in mean ± SD. Decontamination factor is calculated after five cleaning for each group. A total of 160 samples result calculated using four decontaminating agent (tap water, SW, Radiacwash, and spirit), four swipe material (cotton, TP, WP, and AS) for commonly used surface (stainless steel, PVC, Perspex, resin) using direct method by 10 samples (n = 10) for each group. Tap water is the best decontaminating agent compared with SW, Radiac wash and spirit for the laboratory simulated stainless steel, PVC, and Perspex surface material, whereas in case of resin surface material, SW decontaminating agent is showing better effectiveness. Cotton is the best swipe material compared to WP-1, AS and TP for the stainless steel, PVC, Perspex, and resin laboratory simulated surface materials. Perspex and stainless steel are the most suitable and recommended laboratory surface material compared to PVC and resin in nuclear medicine. Radiacwash may show better result for 99mTc labelled product and other radionuclide contamination on the laboratory working surface area.
21 CFR 660.33 - Testing of source material.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660... incorporated into the Reagent Red Blood Cell product shall be individually tested, with no fewer than two donor... tests for each factor. The Reagent Red Blood Cell product may be tested with a single donor source of...
21 CFR 660.33 - Testing of source material.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660... incorporated into the Reagent Red Blood Cell product shall be individually tested, with no fewer than two donor... tests for each factor. The Reagent Red Blood Cell product may be tested with a single donor source of...
21 CFR 660.33 - Testing of source material.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660... incorporated into the Reagent Red Blood Cell product shall be individually tested, with no fewer than two donor... tests for each factor. The Reagent Red Blood Cell product may be tested with a single donor source of...
21 CFR 660.33 - Testing of source material.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660... incorporated into the Reagent Red Blood Cell product shall be individually tested, with no fewer than two donor... tests for each factor. The Reagent Red Blood Cell product may be tested with a single donor source of...
21 CFR 660.33 - Testing of source material.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660... incorporated into the Reagent Red Blood Cell product shall be individually tested, with no fewer than two donor... tests for each factor. The Reagent Red Blood Cell product may be tested with a single donor source of...
Student laboratory presentations as a learning tool in anatomy education.
Chollet, Madeleine B; Teaford, Mark F; Garofalo, Evan M; DeLeon, Valerie B
2009-01-01
Previous studies have shown that anatomy students who complete oral laboratory presentations believe they understand the material better and retain it longer than they otherwise would if they only took examinations on the material; however, we have found no studies that empirically test such outcomes. The purpose of this study was to assess the effectiveness of oral presentations through comparisons with other methods of assessment, most notably, examination performance. Specifically, we tested whether students (n = 256) performed better on examination questions on topics covered by their oral presentations than on other topics. Each student completed two graded, 12-minute laboratory presentations on two different assigned topics during the course and took three examinations, each of which covered a third of the course material. Examination questions were characterized by type (memorization, pathway, analytical, spatial). A two-way repeated measures analysis of variance revealed that students performed better on topics covered by their presentations than on topics not covered by their presentations (P < 0.005), regardless of presentation grade (P > 0.05) and question type (P > 0.05). These results demonstrate empirically that oral presentations are an effective learning tool.
Has compliance with CLIA requirements really improved quality in US clinical laboratories?
Ehrmeyer, Sharon S; Laessig, Ronald H
2004-08-02
The Clinical Laboratory Improvement Amendments of 1988 (CLIA'88) mandate universal requirements for all U.S. clinical laboratory-testing sites. The intent of CLIA'88 is to ensure quality testing through a combination of minimum quality practices that incorporate total quality management concepts. These regulations do not contain established, objective indicators or measures to assess quality. However, there is an implicit assumption that compliance with traditionally accepted good laboratory practices--following manufacturers' directions, routinely analysing quality control materials, applying quality assurance principles, employing and assessing competent testing personnel, and participating in external quality assessment or proficiency testing (PT)--will result in improved test quality. The CLIA'88 regulations do include PT performance standards, which intentionally or unintentionally, define intra-laboratory performance. Passing PT has become a prime motivation for improving laboratory performance; it can also be used as an objective indicator to assess whether compliance to CLIA has improved intra-laboratory quality. Data from 1994 through 2002 indicate that the percentage of laboratories passing PT has increased. In addition to PT performance, subjective indicators of improved quality--frequency of inspection deficiencies, the number of government sanctions for non-compliance, and customer satisfaction--were evaluated. The results from these subjective indicators are more difficult to interpret but also seem to show improved quality in US clinical laboratories eleven years post-CLIA'88.
Permeation of fingerprints through laboratory gloves.
Willinski, G
1980-07-01
Repeated controlled tests have shown that impressions from laboratory gloves will print onto optical components in 20 to 40 min and, in some cases, sooner. Careful testing demonstrated that palmar sweat passed through the glove material; the problem was not that gloves conform to the friction ridges of the fingers and then transfer some contaminant. The problem can be alleviated to a great extent by wearing thin cotton gloves like those commonly used in the film industry.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finch, J.L.
1994-06-01
Military Specifications call out general procedures and guidelines for conducting contact resistance measurements on chemical conversion coated panels. This paper deals with a test procedure developed at Sandia National Laboratories used to conduct contact electrical resistance on non-chromated conversion coated test panels. MIL-C-81706 {open_quotes}Chemical Conversion Materials For Coating Aluminum and Aluminum Alloys{close_quotes} was the reference specification used for guidance.
Use of reinforced inorganic cement materials for spark wire and drift chamber wire frames
NASA Technical Reports Server (NTRS)
1987-01-01
The results of a survey, materials test, and analysis study directed toward the development of an inorganic glass-fiber reinforced cement material for use in the construction of space qualified spark wire frames and drift chamber frames are presented. The purpose for this research was to evaluate the feasibility of using glass fiber reinforced cement (GFRC) for large dimensioned structural frames for supporting a number of precisely located spark wires in multiple planes. A survey of the current state of the art in fiber reinforced cement materials was made; material sample mixes were made and tested to determine their laboratory performances. Tests conducted on sample materials showed that compressive and flexural strengths of this material could approach values which would enable fabrication of structural spark wire frames.
Constitutive Soil Properties for Unwashed Sand and Kennedy Space Center
NASA Technical Reports Server (NTRS)
Thomas, Michael A.; Chitty, Daniel E.; Gildea, Martin L.; T'Kindt, Casey M.
2008-01-01
Accurate soil models are required for numerical simulations of land landings for the Orion Crew Exploration Vehicle. This report provides constitutive material models for one soil, unwashed sand, from NASA Langley's gantry drop test facility and three soils from Kennedy Space Center (KSC). The four soil models are based on mechanical and compressive behavior observed during geotechnical laboratory testing of remolded soil samples. The test specimens were reconstituted to measured in situ density and moisture content. Tests included: triaxial compression, hydrostatic compression, and uniaxial strain. A fit to the triaxial test results defines the strength envelope. Hydrostatic and uniaxial tests define the compressibility. The constitutive properties are presented in the format of LS-DYNA Material Model 5: Soil and Foam. However, the laboratory test data provided can be used to construct other material models. The four soil models are intended to be specific to the soil conditions discussed in the report. The unwashed sand model represents clayey sand at high density. The KSC models represent three distinct coastal sand conditions: low density dry sand, high density in-situ moisture sand, and high density flooded sand. It is possible to approximate other sands with these models, but the results would be unverified without geotechnical tests to confirm similar soil behavior.
Dynamic Shock Response of an S2 Glass/SC15 Epoxy Woven Fabric Composite Material System
NASA Astrophysics Data System (ADS)
Key, Christopher; Alexander, Scott; Harstad, Eric; Schumacher, Shane
2017-06-01
The use of S2 glass/SC15 epoxy woven fabric composite materials for blast and ballistic protection has been an area of on-going research over the past decade. In order to accurately model this material system within potential applications under extreme loading conditions, a well characterized and well understood anisotropic equation of state (EOS) is needed. This work details both an experimental program and associated analytical modelling efforts which aim to provide better physical understanding of the anisotropic EOS behavior of this material. Experimental testing focused on planar shock impact tests loading the composite to peak pressures of 15 GPa in both the through-thickness and on-fiber orientation. Test results highlighted the anisotropic response of the material and provided a basis by which the associated numeric micromechanical investigation was compared. Results of the combined experimental and numerical modelling investigation provided insights into not only the constituent material influence on the composite response but also the importance of the geometrical configuration of the plain weave microstructure and the stochastic significance of the microstructural configuration. Sandia National Laboratories is a multi-mission laboratory operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin company, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.
Biljak, Vanja Radisic; Ozvald, Ivan; Radeljak, Andrea; Majdenic, Kresimir; Lasic, Branka; Siftar, Zoran; Lovrencic, Marijana Vucic; Flegar-Mestric, Zlata
2012-01-01
Introduction The aim of the study was to present a protocol for laboratory information system (LIS) and hospital information system (HIS) validation at the Institute of Clinical Chemistry and Laboratory Medicine of the Merkur University Hospital, Zagreb, Croatia. Materials and methods: Validity of data traceability was checked by entering all test requests for virtual patient into HIS/LIS and printing corresponding barcoded labels that provided laboratory analyzers with the information on requested tests. The original printouts of the test results from laboratory analyzer(s) were compared with the data obtained from LIS and entered into the provided template. Transfer of data from LIS to HIS was examined by requesting all tests in HIS and creating real data in a finding generated in LIS. Data obtained from LIS and HIS were entered into a corresponding template. The main outcome measure was the accuracy of transfer obtained from laboratory analyzers and results transferred from LIS and HIS expressed as percentage (%). Results: The accuracy of data transfer from laboratory analyzers to LIS was 99.5% and of that from LIS to HIS 100%. Conclusion: We presented our established validation protocol for laboratory information system and demonstrated that a system meets its intended purpose. PMID:22384522
Improving accuracy of unbound resilient modulus testing
DOT National Transportation Integrated Search
1997-07-01
The P46 Laboratory Startup and Quality Control Procedure was developed to ensure the accuracy and reliability of the resilient modulus data produced while testing soil and aggregate materials using closed-loop servo-hydraulic systems. It was develope...
ETR ELECTRICAL BUILDING, TRA648, INTERIOR. SWITCHGEAR. INL NEGATIVE NO. 563794. ...
ETR ELECTRICAL BUILDING, TRA-648, INTERIOR. SWITCHGEAR. INL NEGATIVE NO. 56-3794. Jack L. Anderson, Photographer, 11/26/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR ELECTRICAL BUILDING, TRA648. BATTERY ROOM. INL NEGATIVE NO. 563785. ...
ETR ELECTRICAL BUILDING, TRA-648. BATTERY ROOM. INL NEGATIVE NO. 56-3785. Jack L. Anderson, Photographer, 11/26/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
WORKER STACKS GRAPHITE BLOCKS AGAINST INNER SOUTH WALL OF REACTOR. ...
WORKER STACKS GRAPHITE BLOCKS AGAINST INNER SOUTH WALL OF REACTOR. INL NEGATIVE NO. 3925. Unknown Photographer, 12/14/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
PROCESS WATER BUILDING, TRA605. INSIDE A FLASH EVAPORATOR. INL NEGATIVE ...
PROCESS WATER BUILDING, TRA-605. INSIDE A FLASH EVAPORATOR. INL NEGATIVE NO. 3323. Unknown Photographer, 9/12/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Quality assurance practices in Europe: a survey of molecular genetic testing laboratories
Berwouts, Sarah; Fanning, Katrina; Morris, Michael A; Barton, David E; Dequeker, Elisabeth
2012-01-01
In the 2000s, a number of initiatives were taken internationally to improve quality in genetic testing services. To contribute to and update the limited literature available related to this topic, we surveyed 910 human molecular genetic testing laboratories, of which 291 (32%) from 29 European countries responded. The majority of laboratories were in the public sector (81%), affiliated with a university hospital (60%). Only a minority of laboratories was accredited (23%), and 26% was certified. A total of 22% of laboratories did not participate in external quality assessment (EQA) and 28% did not use reference materials (RMs). The main motivations given for accreditation were to improve laboratory profile (85%) and national recognition (84%). Nearly all respondents (95%) would prefer working in an accredited laboratory. In accredited laboratories, participation in EQA (P<0.0001), use of RMs (P=0.0014) and availability of continuous education (CE) on medical/scientific subjects (P=0.023), specific tasks (P=0.0018), and quality assurance (P<0.0001) were significantly higher than in non-accredited laboratories. Non-accredited laboratories expect higher restriction of development of new techniques (P=0.023) and improvement of work satisfaction (P=0.0002) than accredited laboratories. By using a quality implementation score (QIS), we showed that accredited laboratories (average score 92) comply better than certified laboratories (average score 69, P<0.001), and certified laboratories better than other laboratories (average score 44, P<0.001), with regard to the implementation of quality indicators. We conclude that quality practices vary widely in European genetic testing laboratories. This leads to a potentially dangerous situation in which the quality of genetic testing is not consistently assured. PMID:22739339
Devonshire, Alison S; O'Sullivan, Denise M; Honeyborne, Isobella; Jones, Gerwyn; Karczmarczyk, Maria; Pavšič, Jernej; Gutteridge, Alice; Milavec, Mojca; Mendoza, Pablo; Schimmel, Heinz; Van Heuverswyn, Fran; Gorton, Rebecca; Cirillo, Daniela Maria; Borroni, Emanuele; Harris, Kathryn; Barnard, Marinus; Heydenrych, Anthenette; Ndusilo, Norah; Wallis, Carole L; Pillay, Keshree; Barry, Thomas; Reddington, Kate; Richter, Elvira; Mozioğlu, Erkan; Akyürek, Sema; Yalçınkaya, Burhanettin; Akgoz, Muslum; Žel, Jana; Foy, Carole A; McHugh, Timothy D; Huggett, Jim F
2016-08-03
Real-time PCR (qPCR) based methods, such as the Xpert MTB/RIF, are increasingly being used to diagnose tuberculosis (TB). While qualitative methods are adequate for diagnosis, the therapeutic monitoring of TB patients requires quantitative methods currently performed using smear microscopy. The potential use of quantitative molecular measurements for therapeutic monitoring has been investigated but findings have been variable and inconclusive. The lack of an adequate reference method and reference materials is a barrier to understanding the source of such disagreement. Digital PCR (dPCR) offers the potential for an accurate method for quantification of specific DNA sequences in reference materials which can be used to evaluate quantitative molecular methods for TB treatment monitoring. To assess a novel approach for the development of quality assurance materials we used dPCR to quantify specific DNA sequences in a range of prototype reference materials and evaluated accuracy between different laboratories and instruments. The materials were then also used to evaluate the quantitative performance of qPCR and Xpert MTB/RIF in eight clinical testing laboratories. dPCR was found to provide results in good agreement with the other methods tested and to be highly reproducible between laboratories without calibration even when using different instruments. When the reference materials were analysed with qPCR and Xpert MTB/RIF by clinical laboratories, all laboratories were able to correctly rank the reference materials according to concentration, however there was a marked difference in the measured magnitude. TB is a disease where the quantification of the pathogen could lead to better patient management and qPCR methods offer the potential to rapidly perform such analysis. However, our findings suggest that when precisely characterised materials are used to evaluate qPCR methods, the measurement result variation is too high to determine whether molecular quantification of Mycobacterium tuberculosis would provide a clinically useful readout. The methods described in this study provide a means by which the technical performance of quantitative molecular methods can be evaluated independently of clinical variability to improve accuracy of measurement results. These will assist in ultimately increasing the likelihood that such approaches could be used to improve patient management of TB.
MTR WING, TRA604. ONE OF THE LABORATORY UNITS ALONG THE ...
MTR WING, TRA-604. ONE OF THE LABORATORY UNITS ALONG THE SOUTH SIDE WALL. NOTE SINK, CABINET, TABLE, AND HOOD UNITS. DUCT ABOVE RECEIVES CONTAMINATED AIR AND SENDS IT TO FAN HOUSE AND STACK. NOTE PARTITION WALL BEHIND WORK UNITS. THE HEALTH PHYSICS LAB WAS SIMILARLY EQUIPPED. WINDOW AT LEFT EDGE OF VIEW. CARD IN LOWER RIGHT WAS INSERTED BY INL PHOTOGRAPHER TO COVER AN OBSOLETE SECURITY RESTRICTION PRINTED ON ORIGINAL NEGATIVE. INL NEGATIVE NO. 4225. Unknown Photographer, 2/13/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
DOE Office of Scientific and Technical Information (OSTI.GOV)
Forman, S. E.; Themelis, M. P.
The Department of Energy has set a 20-year lifetime goal for terrestrial photovoltaic modules. Massachusetts Institute of Technology's Lincoln Laboratory, in its capacity as a Photovoltaic Field Tests and Applications Center, has established various experimental test sites in the United States ranging in size from 0.1 to 25 kW of peak power. These sites serve as test beds for photovoltaic system components and include modules from several manufacturers. This report summarizes the activities of the Materials, Processes and Testing Laboratory of the Solar Photovoltaic Project during a three-month (10/1/78--12/31/78) period. Particular attention is given to testing and analysis of solarmore » modules from the Mead, Nebraska site, which contains a 25-kW array. A trip to the site was made, where various testing and inspection procedures were followed, in order to ascertain the physical and electrical degradation which had occurred in modules. In addition, several modules were removed for more detailed testing and inspection in the Laboratory. The results of both the field testing and laboratory analyses are reported here.« less
Lipid and lipoprotein testing in resource-limited laboratories.
Myers, Gary L
2003-01-01
The role of total cholesterol (TC) and lipoproteins in the assessment of coronary heart disease (CHD) is firmly established from population and intervention studies. Total and low-density lipoprotein cholesterol (LDLC) levels are positively associated with CHD, and high-density lipoprotein cholesterol (HDLC) levels are negatively associated with CHD. Efforts to identify and treat people at increased risk based on cholesterol and lipoprotein levels have led to more lipid testing and the need for very reliable test results. Thus, quality laboratory services are an essential component of healthcare delivery and play a vital role in any strategy to reduce morbidity and mortality from CHD. In laboratories with limited resources, establishing laboratory capability to measure CHD risk markers may be a considerable challenge. Laboratories face problems in selecting proper techniques, difficulties in equipment availability and maintenance, and shortage of supplies, staffing, and supervision. The Centers for Disease Control and Prevention (CDC) has been providing technical assistance for more than 30 years to laboratories that measure lipids and lipoproteins and is willing to provide technical assistance as needed for other laboratories to develop this capability. CDC can provide technical assistance to establish lipid and lipoprotein testing capability to support a CHD public health program in areas with limited laboratory resources. This assistance includes: selecting a suitable testing instrument; providing training for laboratory technicians; establishing a simple quality control plan; and instructing staff on how to prepare frozen serum control materials suitable for assessing accuracy of lipid and lipoprotein testing.
MTR BUILDING INTERIOR, TRA603. BASEMENT. CAMERA IN WEST CORRIDOR FACING ...
MTR BUILDING INTERIOR, TRA-603. BASEMENT. CAMERA IN WEST CORRIDOR FACING SOUTH. FREIGHT ELEVATOR IS AT RIGHT OF VIEW. AT CENTER VIEW IS MTR VAULT NO. 1, USED TO STORE SPECIAL OR FISSIONABLE MATERIALS. INL NEGATIVE NO. HD46-6-3. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
HOT CELL BUILDING, TRA632, INTERIOR. WRIGHT 3TON HOIST ON EAST ...
HOT CELL BUILDING, TRA-632, INTERIOR. WRIGHT 3-TON HOIST ON EAST SIDE OF CELL 2. SIGN AT LEFT OF VIEW SAYS, "...DO NOT BRING FISSILE MATERIAL INTO AREA WITHOUT APPROVAL." CAMERA FACES NORTHWEST. INL NEGATIVE NO. HD46-29-2. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Abrasion of acrylic veneers by simulated toothbrushing.
Xu, H C; Söremark, R; Wiktorsson, G; Wang, T; Liu, W Y
1984-12-01
The abrasion responses were tested on four acrylic veneer materials, K + B Plus, K + B 75, Isosit, and Ivocron. The studies were performed in two independent research laboratories. Two different brushing machines were used with an abrasive slurry. The results were used for comparing the degree of abrasion for the resin materials. Three analytical methods of measuring the degree of abrasive wear were used: surface profile measurement, microscopic evaluation, and measurement of loss of volume. Isosit showed the best abrasion resistance of the four materials tested.
Quasi-Static Tensile Stress-Strain Curves. 1, 2024-T3510 Aluminum Alloy
1976-02-01
herein were conducted as part of the Core Materials Program of the Solid Mechanics Branch of the Terminal Ballistics Laboratory. The objective of this...describing the results of the Core Materials Program, covers quasi-static terVsile tests of 2024-T3510 aluminum E’lloy. The results include Young’s...11.31 4 580.6 9.94 TABLE II MATERIAL PROPERTIES OF 2024-T3510 ALUMINUM ALLOYa Results of Results of Results of Tensileb Compres ion Sonic Testing
Weisman, David
2010-01-01
Face-to-face bioinformatics courses commonly include a weekly, in-person computer lab to facilitate active learning, reinforce conceptual material, and teach practical skills. Similarly, fully-online bioinformatics courses employ hands-on exercises to achieve these outcomes, although students typically perform this work offsite. Combining a face-to-face lecture course with a web-based virtual laboratory presents new opportunities for collaborative learning of the conceptual material, and for fostering peer support of technical bioinformatics questions. To explore this combination, an in-person lecture-only undergraduate bioinformatics course was augmented with a remote web-based laboratory, and tested with a large class. This study hypothesized that the collaborative virtual lab would foster active learning and peer support, and tested this hypothesis by conducting a student survey near the end of the semester. Respondents broadly reported strong benefits from the online laboratory, and strong benefits from peer-provided technical support. In comparison with traditional in-person teaching labs, students preferred the virtual lab by a factor of two. Key aspects of the course architecture and design are described to encourage further experimentation in teaching collaborative online bioinformatics laboratories. Copyright © 2010 International Union of Biochemistry and Molecular Biology, Inc.
Performance testing accountability measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oldham, R.D.; Mitchell, W.G.; Spaletto, M.I.
The New Brunswick Laboratory (NBL) provides assessment support to the DOE Operations Offices in the area of Material Control and Accountability (MC and A). During surveys of facilities, the Operations Offices have begun to request from NBL either assistance in providing materials for performance testing of accountability measurements or both materials and personnel to do performance testing. To meet these needs, NBL has developed measurement and measurement control performance test procedures and materials. The present NBL repertoire of performance tests include the following: (1) mass measurement performance testing procedures using calibrated and traceable test weights, (2) uranium elemental concentration (assay)more » measurement performance tests which use ampulated solutions of normal uranyl nitrate containing approximately 7 milligrams of uranium per gram of solution, and (3) uranium isotopic measurement performance tests which use ampulated uranyl nitrate solutions with enrichments ranging from 4% to 90% U-235. The preparation, characterization, and packaging of the uranium isotopic and assay performance test materials were done in cooperation with the NBL Safeguards Measurements Evaluation Program since these materials can be used for both purposes.« less
Crashworthiness simulation of composite automotive structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Botkin, M E; Johnson, N L; Simunovic, S
1998-06-01
In 1990 the Automotive Composites Consortium (ACC) began the investigation of crash worthiness simulation methods for composite materials. A contract was given to Livermore Software Technology Corporation (LSTC) to implement a new damage model in LS-DYNA3D TM specifically for composite structures. This model is in LS-DYNA3D TM and is in use by the ACC partners. In 1994 USCAR, a partnership of American auto companies, entered into a partnership called SCAAP (Super Computing Automotive Applications Partnership) for the express purpose of working with the National Labs on computational oriented research. A CRADA (Cooperative Research and Development Agreement) was signed with Lawrencemore » Livermore National Laboratory, Oak Ridge National Laboratory, Sandia National Laboratory, Argonne National Laboratory, and Los Alamos National Laboratory to work in three distinctly different technical areas, one of which was composites material modeling for crash worthiness. Each Laboratory was assigned a specific modeling task. The ACC was responsible for the technical direction of the composites project and provided all test data for code verification. All new models were to be implemented in DYNA3D and periodically distributed to all partners for testing. Several new models have been developed and implemented. Excellent agreement has been shown between tube crush simulation and experiments.« less
Comparison of High-Performance Fiber Materials Properties in Simulated and Actual Space Environments
NASA Technical Reports Server (NTRS)
Finckernor, M. M.
2017-01-01
A variety of high-performance fibers, including Kevlar, Nomex, Vectran, and Spectra, have been tested for durability in the space environment, mostly the low Earth orbital environment. These materials have been tested in yarn, tether/cable, and fabric forms. Some material samples were tested in a simulated space environment, such as the Atomic Oxygen Beam Facility and solar simulators in the laboratory. Other samples were flown on the International Space Station as part of the Materials on International Space Station Experiment. Mass loss due to atomic oxygen erosion and optical property changes due to ultraviolet radiation degradation are given. Tensile test results are also presented, including where moisture loss in a vacuum had an impact on tensile strength.
Wiegand, Cornelia; Völpel, Andrea; Ewald, Andrea; Remesch, Markko; Kuever, Jan; Bauer, Janine; Griesheim, Stefanie; Hauser, Carolin; Thielmann, Julian; Tonndorf-Martini, Silke; Sigusch, Bernd W; Weisser, Jürgen; Wyrwa, Ralf; Elsner, Peter; Hipler, Uta-Christina; Roth, Martin; Dewald, Carolin; Lüdecke-Beyer, Claudia; Bossert, Jörg
2018-01-01
Bactericidal materials gained interest in the health care sector as they are capable of preventing material surfaces from microbial colonization and subsequent spread of infections. However, commercialization of antimicrobial materials requires proof of their efficacy, which is usually done using in vitro methods. The ISO 22196 standard (Japanese test method JIS Z 2801) is a method for measuring the antibacterial activity of daily goods. As it was found reliable for testing the biocidal activity of antimicrobially active materials and surface coatings most of the laboratories participating in this study used this protocol. Therefore, a round robin test for evaluating antimicrobially active biomaterials had to be established. To our knowledge, this is the first report on inaugurating a round robin test for the ISO 22196 / JIS Z 2801. The first round of testing showed that analyses in the different laboratories yielded different results, especially for materials with intermediate antibacterial effects distinctly different efficacies were noted. Scrutinizing the protocols used by the different participants and identifying the factors influencing the test outcomes the approach was unified. Four critical factors influencing the outcome of antibacterial testing were identified in a series of experiments: (1) incubation time, (2) bacteria starting concentration, (3) physiological state of bacteria (stationary or exponential phase of growth), and (4) nutrient concentration. To our knowledge, this is the first time these parameters have been analyzed for their effect on the outcome of testing according to ISO 22196 / JIS Z 2801. In conclusion, to enable assessment of the results obtained it is necessary to evaluate these single parameters in the test protocol carefully. Furthermore, uniform and robust definitions of the terms antibacterial efficacy / activity, bacteriostatic effects, and bactericidal action need to be agreed upon to simplify communication of results and also regulate expectations regarding antimicrobial tests, outcomes, and materials.
Völpel, Andrea; Ewald, Andrea; Remesch, Markko; Kuever, Jan; Bauer, Janine; Griesheim, Stefanie; Hauser, Carolin; Thielmann, Julian; Tonndorf-Martini, Silke; Sigusch, Bernd W.; Weisser, Jürgen; Wyrwa, Ralf; Elsner, Peter; Hipler, Uta-Christina; Roth, Martin; Dewald, Carolin; Lüdecke-Beyer, Claudia; Bossert, Jörg
2018-01-01
Bactericidal materials gained interest in the health care sector as they are capable of preventing material surfaces from microbial colonization and subsequent spread of infections. However, commercialization of antimicrobial materials requires proof of their efficacy, which is usually done using in vitro methods. The ISO 22196 standard (Japanese test method JIS Z 2801) is a method for measuring the antibacterial activity of daily goods. As it was found reliable for testing the biocidal activity of antimicrobially active materials and surface coatings most of the laboratories participating in this study used this protocol. Therefore, a round robin test for evaluating antimicrobially active biomaterials had to be established. To our knowledge, this is the first report on inaugurating a round robin test for the ISO 22196 / JIS Z 2801. The first round of testing showed that analyses in the different laboratories yielded different results, especially for materials with intermediate antibacterial effects distinctly different efficacies were noted. Scrutinizing the protocols used by the different participants and identifying the factors influencing the test outcomes the approach was unified. Four critical factors influencing the outcome of antibacterial testing were identified in a series of experiments: (1) incubation time, (2) bacteria starting concentration, (3) physiological state of bacteria (stationary or exponential phase of growth), and (4) nutrient concentration. To our knowledge, this is the first time these parameters have been analyzed for their effect on the outcome of testing according to ISO 22196 / JIS Z 2801. In conclusion, to enable assessment of the results obtained it is necessary to evaluate these single parameters in the test protocol carefully. Furthermore, uniform and robust definitions of the terms antibacterial efficacy / activity, bacteriostatic effects, and bactericidal action need to be agreed upon to simplify communication of results and also regulate expectations regarding antimicrobial tests, outcomes, and materials. PMID:29558480
GRAPHITE BLOCKS ARE ARRAYED IN "THERMAL COLUMN" ON NORTH SIDE ...
GRAPHITE BLOCKS ARE ARRAYED IN "THERMAL COLUMN" ON NORTH SIDE OF REACTOR. INL NEGATIVE NO. 4000. Unknown Photographer, 12/28/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
MTR BASEMENT. GENERAL ELECTRIC CONTROL CONSOLE FOR AIRCRAFT NUCLEAR PROPULSION ...
MTR BASEMENT. GENERAL ELECTRIC CONTROL CONSOLE FOR AIRCRAFT NUCLEAR PROPULSION EXPERIMENT NO. 1. INL NEGATIVE NO. 6510. Unknown Photographer, 9/29/1959 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
PRECAST CONCRETE WALL PANELS ARE LIFTED INTO PLACE ON MTR ...
PRECAST CONCRETE WALL PANELS ARE LIFTED INTO PLACE ON MTR STEEL FRAME STRUCTURE. INL NEGATIVE NO. 1330. Unknown Photographer, 1/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
FAST CHOPPER BUILDING, TRA665, INTERIOR. UPPER LEVEL. CONCRETE WALLS. INL ...
FAST CHOPPER BUILDING, TRA-665, INTERIOR. UPPER LEVEL. CONCRETE WALLS. INL NEGATIVE NO. HD42-2. Mike Crane, Photographer, 3/2004 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
NASA Technical Reports Server (NTRS)
Sepka, Steven; Gasch, Matthew; Beck, Robin A.; White, Susan
2012-01-01
The material testing results described in this paper were part of a material development program of vendor-supplied, proposed heat shield materials. The goal of this program was to develop low density, rigid material systems with an appreciable weight savings over phenolic-impregnated carbon ablator (PICA) while improving material response performance. New technologies, such as PICA-like materials in honeycomb or materials with variable density through-the-thickness were tested. The material testing took place at the Wright-Patterson Air Force Base Laser Hardened Materials Laboratory (LHMEL) using a 10.6 micron CO2 laser operating with the test articles immersed in a nitrogen-gas environment at 1 atmosphere pressure. Test measurements included thermocouple readings of in-depth temperatures, pyrometer readings of surface temperatures, weight scale readings of mass loss, and sectioned-sample readings of char depth. Two laser exposures were applied. The first exposure was at an irradiance of 450 W/cm2 for 50 or 60 seconds to simulate an aerocapture maneuver. The second laser exposure was at an irradiance of 115 W/cm2 for 100 seconds to simulate a planetary entry. Results from Rounds 1 and 2 of these screening tests are summarized.
2003-08-21
KENNEDY SPACE CENTER, FLA. - On a tour of the KSC Beach Corrosion Test Site, Louis MacDowell (right), Testbed manager, explains to Center Director Jim Kennedy a project being undertaken for the U.S. Navy. At left are nonchrome primers for aircraft being studied. Behind Kennedy is Lead Scientist Dr. Luz Marina Calle. Behind MacDowell is Dr. Paul Hintze, who is working on a graduate project for the National Research Council. The KSC Beach Corrosion Test Site was established in the 1960s and has provided more than 30 years of historical information on the long-term performance of many materials in use at KSC and other locations around the world. Located 100 feet from the Atlantic Ocean approximately 1 mile south of the Space Shuttle launch sites, the test facility includes an atmospheric exposure site, a flowing seawater exposure site, and an on-site electrochemistry laboratory and monitoring station. The beach laboratory is used to conduct real-time corrosion experiments and provides for the remote monitoring of surrounding weather conditions. The newly added flowing seawater immersion facility provides for the immersion testing of materials and devices under controlled conditions.
2003-08-21
KENNEDY SPACE CENTER, FLA. - On a tour of the KSC Beach Corrosion Test Site, Center Director Jim Kennedy (second from right) learns from Testbed Manager Louis MacDowell (right) about a project being undertaken for the U.S. Navy. Being studied are nonchrome primers for aircraft. At left are Lead Scientist Dr. Luz Marina Calle and Dr. Paul Hintze, who is working on a graduate project for the National Research Council. The KSC Beach Corrosion Test Site was established in the 1960s and has provided more than 30 years of historical information on the long-term performance of many materials in use at KSC and other locations around the world. Located 100 feet from the Atlantic Ocean approximately 1 mile south of the Space Shuttle launch sites, the test facility includes an atmospheric exposure site, a flowing seawater exposure site, and an on-site electrochemistry laboratory and monitoring station. The beach laboratory is used to conduct real-time corrosion experiments and provides for the remote monitoring of surrounding weather conditions. The newly added flowing seawater immersion facility provides for the immersion testing of materials and devices under controlled conditions.
2003-08-21
KENNEDY SPACE CENTER, FLA. - On a tour of the KSC Beach Corrosion Test Site, Testbed Manager Louis MacDowell (foreground) explains to Center Director Jim Kennedy (third from right) about a study being undertaken for the U.S. Navy: nonchrome primers for aircraft. At left is Lead Scientist Dr. Luz Marina Calle and behind MacDowell is Dr. Paul Hintze, who is working on a graduate project for the National Research Council. The KSC Beach Corrosion Test Site was established in the 1960s and has provided more than 30 years of historical information on the long-term performance of many materials in use at KSC and other locations around the world. Located 100 feet from the Atlantic Ocean approximately 1 mile south of the Space Shuttle launch sites, the test facility includes an atmospheric exposure site, a flowing seawater exposure site, and an on-site electrochemistry laboratory and monitoring station. The beach laboratory is used to conduct real-time corrosion experiments and provides for the remote monitoring of surrounding weather conditions. The newly added flowing seawater immersion facility provides for the immersion testing of materials and devices under controlled conditions.
Evaluation of a standard test method for screening fuels in soils
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sorini, S.S.; Schabron, J.F.
1996-12-31
A new screening method for fuel contamination in soils was recently developed as American Society for Testing and Materials (ASTM) Method D-5831-95, Standard Test Method for Screening Fuels in Soils. This method uses low-toxicity chemicals and can be sued to screen organic- rich soils, as well as being fast, easy, and inexpensive to perform. Fuels containing aromatic compounds, such as diesel fuel and gasoline, as well as other aromatic-containing hydrocarbon materials, such as motor oil, crude oil, and cola oil, can be determined. The screening method for fuels in soils was evaluated by conducting a Collaborative study on the method.more » In the Collaborative study, a sand and an organic soil spiked with various concentrations of diesel fuel were tested. Data from the Collaborative study were used to determine the reproducibility (between participants) and repeatability (within participants) precision of the method for screening the test materials. The Collaborative study data also provide information on the performance of portable field equipment (patent pending) versus laboratory equipment for performing the screening method and a comparison of diesel concentration values determined using the screening method versus a laboratory method.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harvey, Scott D.; He, Lijian; Wahl, Jon H.
2012-08-30
This study provides a preliminary evaluation of the Field and Laboratory Emission Cell (FLEC) for its suitability for sampling building materials for toxic compounds and their associated impurities and residues that might remain after a terrorist chemical attack. Chemical warfare (CW) agents and toxic industrial chemicals were represented by a range of test probes that included CW surrogates. The test probes encompassed the acid-base properties, volatilities, and polarities of the expected chemical agents and residual compounds. Results indicated that dissipation of the test probes depended heavily on the underlying material. Near complete dissipation of almost all test probes occurred frommore » galvanized stainless steel within 3.0 hrs, whereas far stronger retention with concomitant slower release was observed for vinyl composition floor tiles. The test probes displayed immediated permanence on Teflon. FLEC sampling was further evaluated by profiling residues remaining after the evaporation of 2-chloroethyl ethyl sulfide, a sulfur mustard simulant. This study lays the groundwork for the eventual goal of applying this sampling approach for collection of forensic attribution signatures that remain after a terrorist chemical attack.« less
A numerical simulation on the flow of watershed filtration reactors using lignocellulosic materials
N. Hur; B. Choi; J.S. Han; E.W. Shin; S. Min; R.M. Rowell
2003-01-01
Pinyon juniper, a small-diameter and underutilized (SDU) lignocellulosic material, was harvested in New Mexico, identified as Juniperus monosperma at the USDA Forest Products Laboratory, chipped, fiberized and chemically modified to remove pollutants from wastewater. This juniper species was selected as a raw material through screening test for removal of pollutants...
Cone calorimeter tests of wood-based decking materials
Robert H. White; Mark A. Dietenberger; Nicole M. Stark
2007-01-01
New technologies in building materials have resulted in the use of a wide variety of materials in decks. As part of our effort to address fire concerns in the wildland-urban interface, the Forest Products Laboratory has been examining the fire performance of decking products. In addition to preservative-treated wood, decking products include wood-plastic composites and...
Oleanna Math Program Materials.
ERIC Educational Resources Information Center
Coole, Walter A.
This document is a collection of course outlines, syllabi, and test materials designed for several high school level and lower division mathematics courses taught in an auto-tutorial learning laboratory at Skagit Valley College (Washington). The courses included are: Pre-Algebra, Basic Algebra, Plan Geometry, Intermediate Algebra, Probability and…
A&M. Special shielding materials. Stockpile of magnetite, used for making ...
A&M. Special shielding materials. Stockpile of magnetite, used for making high-density concrete, and loading conveyor near TAN-607 construction site. Date: September 25, 1953. INEEL negative no. 8710 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
DOT National Transportation Integrated Search
2008-01-01
This research involved a detailed laboratory study of a new test method for evaluating road base materials based on : the strength of the soil binder. In this test method, small test specimens (5.0in length and 0.75in square cross : section) of binde...
Laboratory Characterization of Solid Grade SW Brick
2007-08-01
Society for Testing and Materials (ASTM) D 2216 (ASTM 2002e). Based on the appropriate values of posttest water content, wet density, and an assumed...strain path (UX/SP) tests. In addition to the mechanical property tests, nondestructive pulse-velocity measurements were performed on each specimen...Figure 3. Spring-arm lateral deformeter mounted on test specimen
Brown, Geoffrey W.; Sandstrom, Mary M.; Preston, Daniel N.; ...
2014-11-17
In this study, the Integrated Data Collection Analysis (IDCA) program has conducted a proficiency test for small-scale safety and thermal (SSST) testing of homemade explosives (HMEs). Described here are statistical analyses of the results from this test for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of the RDX Class 5 Type II standard. The material was tested as a well-characterized standard several times during the proficiency test to assess differences among participants and the range of results that may arise for well-behaved explosive materials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Windisch, C.F. Jr.; Strachan, D.M.; Henager, C.H. Jr.
Cermet anodes were evaluated as nonconsumable substitutes for carbon anodes using a pilot-scale reduction cell at the Reynolds Manufacturing Technology Laboratory. After pilot cell testing, tile anodes were subjected to extensive materials characterization and physical properties measurements at the Pacific Northwest Laboratory. Significant changes in the composition of the cermet anodes were observed including the growth of a reaction layer and penetration of electrolyte deep into the cermet matrix. Fracture strength and toughness were measured as a function of temperature and the ductile-brittle transition wasreduced by 500C following pilot cell testing. These results imply difficulties with anode material and controlmore » of operating conditions in the pilot cell, and suggest that additional development work be performed before the cermet anodes are used in commercial reduction cells. The results also highlight specific fabrication and operational considerations that should be addressed in future testing.« less
Zhang, M.; Takahashi, M.; Morin, R.H.; Esaki, T.
1998-01-01
A theoretical analysis is presented that compares the response characteristics of the constant head and the constant flowrate (flow pump) laboratory techniques for quantifying the hydraulic properties of geologic materials having permeabilities less than 10-10 m/s. Rigorous analytical solutions that describe the transient distributions of hydraulic gradient within a specimen are developed, and equations are derived for each method. Expressions simulating the inflow and outflow rates across the specimen boundaries during a constant-head permeability test are also presented. These solutions illustrate the advantages and disadvantages of each method, including insights into measurement accuracy and the validity of using Darcy's law under certain conditions. The resulting observations offer practical considerations in the selection of an appropriate laboratory test method for the reliable measurement of permeability in low-permeability geologic materials.
Force instrumentation for cryogenic wind tunnels using one-piece strain-gage balances
NASA Technical Reports Server (NTRS)
Ferris, A. T.
1980-01-01
The use of cryogenic temperatures in wind tunnels to achieve high Reynolds numbers has imposed a harsh operating environment on the force balance. Laboratory tests were conducted to study the effect cryogenic temperatures have on balance materials, gages, wiring, solder, adhesives, and moisture proofing. Wind tunnel tests were conducted using a one piece three component balance to verify laboratory results. These initial studies indicate that satisfactory force data can be obtained under steady state conditions.
[Surface aspect of fixed restaurations and parodontal influences].
Ciocan-Pendefunda, Alice-Arina; Forna, Norina Consuela
2012-01-01
Any new class of materials requires a new cutting technology which, unless complied with properly, may negatively impact on the advantages and performance of the material. The modifications appeared as a result of the technological processes in the structure or surface aspect of the materials not only affects the mechanical resistance of the restorations but also casts doubts on their biological qualities. This study evaluates the impact of biomaterials involved in fixed restorations on the periodontal architecture, bearing extremely important connotations in the long run. The "in vitro" testing was conducted on culture cells for the cytotoxic effect of certain restorative materials--metallic alloys used in prosthetic restorations, composite materials, in collaboration with the Virology Laboratory of the Public Health Institute.The tested materials were metallic alloys, composite materials and acrylic resins used for the construction of standard sized plates (out of each material) in order to avoid the differences that might arise from the technological process. Artificial saliva processed to reach a pH = 7 was prepared in the Biophysics Laboratory of UMF Iasi. Material samples and the saliva inoculated with these were tested. -p. The cytotoxic effect of the tested materials on the celular cultures takes on extremely diverse forms, from discrete morphological modifications of the cells with regard to the size, shape, internal structure (for the noble and semi-noble alloys) up to the partial stripping-off of the celular film, the modification of density and coloration. In the case of the witness of non-inoculated culture, the testing results showed the presence of a continuous film, with cells having the same size, transparency and colouring, with an unaltered polyhedral contour, with visible nuclei, an image also kept in the case of the saliva witness. The involvement of restaurative materials in triggering, maintaining and aggravating a periodontal pathology indicates the capital role played by the dentist in the identications of lesions during measures by avoiding or excluding etiological agents before an obvious lesions occurs in the process of active dispensarization.
Learning of Musculoskeletal Ligament Stress Testing in a Gross Anatomy Laboratory
ERIC Educational Resources Information Center
Krause, David A.; Youdas, James W.; Hollman, John H.
2011-01-01
Human anatomy in physical therapy programs is a basic science course serving as a foundation for subsequent clinical courses. Integration of anatomy with a clinical emphasis throughout a curriculum provides opportunities for reinforcement of previously learned material. Considering the human cadaver laboratory as a fixed cost to our program, we…
46 CFR 159.010-3 - Independent laboratory: Standards for acceptance.
Code of Federal Regulations, 2010 CFR
2010-10-01
... engaged, as a regular part of its business, in performing inspections and tests that are the same as or... manufacturer; (4) Not be dependent on Coast Guard acceptance under this subchapter to remain in business; and (5) Not advertise or promote the manufacturer's equipment or material that the laboratory inspects...
Orbital surveys of solar stimulated luminescence
NASA Astrophysics Data System (ADS)
Hemphill, W. R.; Theisen, A. F.; Tyson, R. M.; Granata, J. S.
The Fraunhofer line discriminator (FLD) is an electro-optical device for imaging natural and manmade materials which have been stimulated to luminesce by the sun. An airborne FLD has been used to detect geochemically stressed vegetation, drought-stressed agricultural crops, industrial and residential pollution effluents, marine oil seeps, phosphate rock, uranium-bearing sandstone, and bioluminescent ocean plankton. Three-dimensional perspective plots of excitation and emission spectra, measured with a laboratory spectrometer, graphically depict similarities and differences in luminescence properties between sample materials. The laboratory data also include luminescence intensities at six Fraunhofer lines in the visible and near-infrared regions of the electromagnetic spectrum. Both the airborne and laboratory data suggest the feasibility of delineating and monitoring at least some of these luminescing materials from orbital altitude, such as a test flight aboard the Space Shuttle using an improved third-generation FLD.
NASA Technical Reports Server (NTRS)
Ankenman, Bruce; Ermer, Donald; Clum, James A.
1994-01-01
Modules dealing with statistical experimental design (SED), process modeling and improvement, and response surface methods have been developed and tested in two laboratory courses. One course was a manufacturing processes course in Mechanical Engineering and the other course was a materials processing course in Materials Science and Engineering. Each module is used as an 'experiment' in the course with the intent that subsequent course experiments will use SED methods for analysis and interpretation of data. Evaluation of the modules' effectiveness has been done by both survey questionnaires and inclusion of the module methodology in course examination questions. Results of the evaluation have been very positive. Those evaluation results and details of the modules' content and implementation are presented. The modules represent an important component for updating laboratory instruction and to provide training in quality for improved engineering practice.
NASA Technical Reports Server (NTRS)
Stambler, Arielle H.; Inoshita, Karen E.; Roberts, Lily M.; Barbagallo, Claire E.; deGroh, Kim K.; Banks, Bruce A.
2011-01-01
The Materials International Space Station Experiment 2 (MISSE 2) Polymer Erosion and Contamination Experiment (PEACE) polymers were exposed to the environment of low Earth orbit (LEO) for 3.95 years from 2001 to 2005. There were 41 different PEACE polymers, which were flown on the exterior of the International Space Station (ISS) in order to determine their atomic oxygen erosion yields. In LEO, atomic oxygen is an environmental durability threat, particularly for long duration mission exposures. Although spaceflight experiments, such as the MISSE 2 PEACE experiment, are ideal for determining LEO environmental durability of spacecraft materials, ground-laboratory testing is often relied upon for durability evaluation and prediction. Unfortunately, significant differences exist between LEO atomic oxygen exposure and atomic oxygen exposure in ground-laboratory facilities. These differences include variations in species, energies, thermal exposures and radiation exposures, all of which may result in different reactions and erosion rates. In an effort to improve the accuracy of ground-based durability testing, ground-laboratory to in-space atomic oxygen correlation experiments have been conducted. In these tests, the atomic oxygen erosion yields of the PEACE polymers were determined relative to Kapton H using a radio-frequency (RF) plasma asher (operated on air). The asher erosion yields were compared to the MISSE 2 PEACE erosion yields to determine the correlation between erosion rates in the two environments. This paper provides a summary of the MISSE 2 PEACE experiment; it reviews the specific polymers tested as well as the techniques used to determine erosion yield in the asher, and it provides a correlation between the space and ground laboratory erosion yield values. Using the PEACE polymers asher to in-space erosion yield ratios will allow more accurate in-space materials performance predictions to be made based on plasma asher durability evaluation.
Recent developments in the field of environmental reference materials at the JRC Ispra.
Muntau, H
2001-06-01
The production of reference materials for environmental analysis started in the Joint Research Centre at Ispra/Italy in 1972 with the objective of later certification by the BCR, but for obvious budget reasons only a fraction of the total production achieved at Ispra ever reached certification level, although all materials were produced according to the severe quality requirements requested for certified reference materials. Therefore, the materials not destinated to certification are in growing demand as inter-laboratory test materials and as laboratory reference materials, for internal quality control, e.g., by control charts. The history of reference material production within the Joint Research Centre is briefly reviewed and the latest additions described. New developments such as micro-scale reference materials intended for analytical methods requiring sample intakes at milligram or sub-milligram level and therefor not finding supply on the reference material market, and "wet" environmental reference materials, which meet more precisely the "real-world" environmental analysis conditions, are presented and the state-of-the-art discussed.
Environmental exposure effects on composite materials for commercial aircraft
NASA Technical Reports Server (NTRS)
Gibbins, M. N.; Hoffman, D. J.
1982-01-01
The effects of environmental exposure on composite materials are studied. The environments considered are representative of those experienced by commercial jet aircraft. Initial results have been compiled for the following material systems: T300/5208, T300/5209 and T300/934. Specimens were exposed on the exterior and interior of Boeing 737 airplanes of three airlines, and to continuous ground level exposure at four locations. In addition specimens were exposed in the laboratory to conditions such as: simulated ground-air-ground, weatherometer, and moisture. Residual strength results are presented for specimens exposed for up to two years at three ground level exposure locations and on airplanes from two airlines. Test results are also given for specimens exposed to the laboratory simulated environments. Test results indicate that short beam shear strength is sensitive to environmental exposure and dependent on the level of absorbed moisture.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goldberg, A.; Lesuer, D.R.; Patt, J.
In order to effectively utilize fractography as an aid in identifying the influence of material and service (or test) parameters on material properties, one must first understand the origin of the morphological features developed during the tearing and fracturing of these elastomers. At our laboratory, we have made extensive fractographic studies while evaluating the effects of material formulations, temperature, and loading rates on the loading response, tearing energy, induced damage, and tearing phenomena in SBR (Styrene Butadiene Rubber) containing different amounts of CB (Carbon Black) filler. We have also examined failures in tank track pads, as well as laboratory-tested samplesmore » cut from new track pads. In this paper we report on observations made during the actual stretching, tearing and failure of elastomeric samples pulled in tension at a constraint stroke-diplacement rate. 15 refs., 12 figs.« less
Zeleny, Reinhard; Nia, Yacine; Schimmel, Heinz; Mutel, Isabelle; Hennekinne, Jacques-Antoine; Emteborg, Håkan; Charoud-Got, Jean; Auvray, Frédéric
2016-08-01
Staphylococcal enterotoxins (SEs) account for a substantial number of food-poisoning outbreaks. European legislation (Commission Regulation 1441/2007) stipulates the reference procedure for SE analysis in milk and dairy products, which is based on extraction, dialysis concentration and immunochemical detection using one of two approved assays (VIDAS(®) SET2, Ridascreen(®) SET Total). However, certified reference materials (CRMs) are lacking to support laboratories in performing reliable detection of Staphylococcus aureus enterotoxin A (SEA) in relevant matrices at sub-nanogram per gram levels. The certification of a set of three reference materials (blank and two SEA-containing materials) for testing of the presence/absence of SEA in cheese is described. The reference procedure was applied in an intercomparison with 15 laboratories, and results were reported in a qualitative manner (presence or absence of SEA in the sample). No false-negative or false-positive results were obtained. The certified values were stated as diagnostic specificity (blank material) or diagnostic sensitivity (SEA-containing materials) and were 100 % in all cases. Stability studies demonstrated suitable material stability when stored cooled or frozen. An in-house study on the recovery of SEA in the cheese materials using a double-sandwich enzyme-linked immunosorbent assay (ELISA) revealed comparable recovery values of around 45 % at the two spiking levels and in both the SEA-containing CRMs as well as blank CRM freshly spiked prior to analysis. The values were also comparable over time and among different analysts. The materials provide valuable support to laboratories for method validation and method performance verification and will increase the reliability of measuring SEA in cheese.
10 CFR 431.20 - Department of Energy recognition of nationally recognized certification programs.
Code of Federal Regulations, 2011 CFR
2011-01-01
... requirements for the competence of calibration and testing laboratories. (4) Expertise in electric motor test... PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Electric Motors Test Procedures, Materials... to assure that basic models of electric motor continue to conform to the efficiency levels for which...
Dye to use with virus challenge for testing barrier materials.
Lytle, C D; Felten, R P; Truscott, W
1991-01-01
Can FD&C Blue no. 1 dye photoinactivate bacteriophages phi X174, T7, PRD1, and phi 6 under laboratory lighting conditions? At high levels of light, the dye (500 microM) photoinactivated only phi 6. Thus, this dye can be used at concentrations up to 500 microM with bacteriophages phi X174, T7, and PRD1 to test barrier material integrity. PMID:1872612
DOE Office of Scientific and Technical Information (OSTI.GOV)
Janke, Christopher James; Das, Sadananda; Oyola, Yatsandra
This report describes work on the successful completion of Milestone M2FT-15OR0310041 (1/30/2015) entitled, Demonstrate braided material with 3.5 g U/kg sorption capacity under seawater testing condition . This effort is part of the Seawater Uranium Recovery Program, sponsored by the U.S. Department of Energy, Office of Nuclear Energy, and involved the development of new adsorbent braided materials at the Oak Ridge National Laboratory (ORNL) and marine testing at the Pacific Northwest National Laboratory (PNNL). ORNL has recently developed four braided fiber adsorbents that have demonstrated uranium adsorption capacities greater than 3.5 g U/kg adsorbent after marine testing at PNNL. Themore » braided adsorbents were synthesized by braiding or leno weaving high surface area polyethylene fibers and conducting radiation-induced graft polymerization of itaconic acid and acrylonitrile monomers onto the braided materials followed by amidoximation and base conditioning. The four braided adsorbents demonstrated capacity values ranging from 3.7 to 4.2 g U/kg adsorbent after 56 days of exposure in natural coastal seawater at 20 oC. All data are normalized to a salinity of 35 psu.« less
NASA Johnson Space Center: White Sands Test Facility
NASA Technical Reports Server (NTRS)
Aggarwal, Pravin; Kowalski, Robert R.
2011-01-01
This slide presentation reviews the testing facilities and laboratories available at the White Sands Test Facility (WSTF). The mission of WSTF is to provide the expertise and infrastructure to test and evaluate spacecraft materials, components and propulsion systems that enable the safe exploration and use of space. There are nine rocket test stands in two major test areas, six altitude test stands, three ambient test stands,
Sandia and General Motors: Advancing Clean Combustion Engines with
Quantitative Risk Assessment Technical Reference for Hydrogen Compatibility of Materials Hydrogen Battery Abuse Testing Laboratory Center for Infrastructure Research and Innovation Combustion Research Facility Joint BioEnergy Institute Close Energy Research Programs ARPA-E Basic Energy Sciences Materials
46 CFR 164.013-6 - Production tests, inspections, and marking.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL MATERIALS Foam, Unicellular Polyethylene (Buoyant... shall provide in-plant quality control of polyethylene foam in accordance with the requirements of § 164.019-13 and any requirements of the recognized laboratory. The manufacturer of the foam has primary...
46 CFR 164.013-6 - Production tests, inspections, and marking.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL MATERIALS Foam, Unicellular Polyethylene (Buoyant... shall provide in-plant quality control of polyethylene foam in accordance with the requirements of § 164.019-13 and any requirements of the recognized laboratory. The manufacturer of the foam has primary...
ERIC Educational Resources Information Center
Scott, Alan
2013-01-01
A simple apparatus is described which serves as a materials testing laboratory. Bolts are placed in it and subjected to tensile and torsional stress while being tightened. The tensile and torsional stress and strain can be measured, which enables the determination of several mechanical properties of the bolt material, including Young's…
Evaluation of the laboratory mouse model for screening topical mosquito repellents.
Rutledge, L C; Gupta, R K; Wirtz, R A; Buescher, M D
1994-12-01
Eight commercial repellents were tested against Aedes aegypti 0 and 4 h after application in serial dilution to volunteers and laboratory mice. Results were analyzed by multiple regression of percentage of biting (probit scale) on dose (logarithmic scale) and time. Empirical correction terms for conversion of values obtained in tests on mice to values expected in tests on human volunteers were calculated from data obtained on 4 repellents and evaluated with data obtained on 4 others. Corrected values from tests on mice did not differ significantly from values obtained in tests on volunteers. Test materials used in the study were dimethyl phthalate, butopyronoxyl, butoxy polypropylene glycol, MGK Repellent 11, deet, ethyl hexanediol, Citronyl, and dibutyl phthalate.
Optical/thermal analysis methodology for a space-qualifiable RTP furnace
NASA Technical Reports Server (NTRS)
Bugby, D.; Dardarian, S.; Cole, E.
1993-01-01
A methodology to predict the coupled optical/thermal performance of a reflective cavity heating system was developed and a laboratory test to verify the method was carried out. The procedure was utilized to design a rapid thermal processing (RTP) furnace for the Robot-Operated Material Processing in Space (ROMPS) Program which is a planned STS HH-G canister experiment involving robotics and material processing in microgravity. The laboratory test employed a tungsten-halogen reflector/lamp to heat thin, p-type silicon wafers. Measurements instrumentation consisted of 5-mil Pt/Pt-Rh thermocouples and an optical pyrometer. The predicted results, utilizing an optical ray-tracing program and a lumped-capacitance thermal analyzer, showed good agreement with the measured data for temperatures exceeding 1300 C.
NASA Astrophysics Data System (ADS)
Gruzin, A. V.; Gruzin, V. V.; Shalay, V. V.
2017-08-01
The development of technology for a directional soil compaction of tank foundations for oil and oil products storage is a relevant problem which solution will enable simultaneously provide required operational characteristics of a soil foundation and reduce time and material costs to prepare the foundation. The impact dynamics of rammers' operating elements on the soil foundation is planned to specify in the course of laboratory studies. A specialized technique is developed to justify the parameters and select the equipment for laboratory researches. The usage of this technique enabled us to calculate dimensions of the models, of a test bench and specifications of the recording equipment, and a lighting system. The necessary equipment for laboratory studies was selected. Preliminary laboratory tests were carried out. The estimate of accuracy for planned laboratory studies was given.
Dobnik, David; Demšar, Tina; Huber, Ingrid; Gerdes, Lars; Broeders, Sylvia; Roosens, Nancy; Debode, Frederic; Berben, Gilbert; Žel, Jana
2018-01-01
Digital PCR (dPCR), as a new technology in the field of genetically modified (GM) organism (GMO) testing, enables determination of absolute target copy numbers. The purpose of our study was to test the transferability of methods designed for quantitative PCR (qPCR) to dPCR and to carry out an inter-laboratory comparison of the performance of two different dPCR platforms when determining the absolute GM copy numbers and GM copy number ratio in reference materials certified for GM content in mass fraction. Overall results in terms of measured GM% were within acceptable variation limits for both tested dPCR systems. However, the determined absolute copy numbers for individual genes or events showed higher variability between laboratories in one third of the cases, most possibly due to variability in the technical work, droplet size variability, and analysis of the raw data. GMO quantification with dPCR and qPCR was comparable. As methods originally designed for qPCR performed well in dPCR systems, already validated qPCR assays can most generally be used for dPCR technology with the purpose of GMO detection. Graphical abstract The output of three different PCR-based platforms was assessed in an inter-laboratory comparison.
Rapid Radiochemical Methods for Asphalt Paving Material ...
Technical Brief Validated rapid radiochemical methods for alpha and beta emitters in solid matrices that are commonly encountered in urban environments were previously unavailable for public use by responding laboratories. A lack of tested rapid methods would delay the quick determination of contamination levels and the assessment of acceptable site-specific exposure levels. Of special concern are matrices with rough and porous surfaces, which allow the movement of radioactive material deep into the building material making it difficult to detect. This research focuses on methods that address preparation, radiochemical separation, and analysis of asphalt paving materials and asphalt roofing shingles. These matrices, common to outdoor environments, challenge the capability and capacity of very experienced radiochemistry laboratories. Generally, routine sample preparation and dissolution techniques produce liquid samples (representative of the original sample material) that can be processed using available radiochemical methods. The asphalt materials are especially difficult because they do not readily lend themselves to these routine sample preparation and dissolution techniques. The HSRP and ORIA coordinate radiological reference laboratory priorities and activities in conjunction with HSRP’s Partner Process. As part of the collaboration, the HSRP worked with ORIA to publish rapid radioanalytical methods for selected radionuclides in building material matrice
Physical Characteristics of Laboratory Tested Concrete as a Substituion of Gravel on Normal Concrete
NASA Astrophysics Data System (ADS)
Butar-butar, Ronald; Suhairiani; Wijaya, Kinanti; Sebayang, Nono
2018-03-01
Concrete technology is highly potential in the field of construction for structural and non-structural construction. The amount uses of this concrete material raise the problem of solid waste in the form of concrete remaining test results in the laboratory. This waste is usually just discarded and not economically valuable. In solving the problem, this experiment was made new materials by using recycle material in the form of recycled aggregate which aims to find out the strength characteristics of the used concrete as a gravel substitution material on the normal concrete and obtain the value of the substitution composition of gravel and used concrete that can achieve the strength of concrete according to the standard. Testing of concrete characteristic is one of the requirements before starting the concrete mixture. This test using SNI method (Indonesian National Standard) with variation of comparison (used concrete : gravel) were 15: 85%, 25: 75%, 35:65%, 50:50 %, 75: 25%. The results of physical tests obtained the mud content value of the mixture gravel and used concrete is 0.03 larger than the standard of SNI 03-4142-1996 that is equal to 1.03%. so the need watering or soaking before use. The water content test results show an increase in the water content value if the composition of the used concrete increases. While the specific gravity value for variation 15: 85% until 35: 65% fulfilled the requirements of SNI 03-1969-1990. the other variasion show the specifics gravity value included on the type of light materials.
Wellbore Seal Repair Using Nanocomposite Materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stormont, John
2016-08-31
Nanocomposite wellbore repair materials have been developed, tested, and modeled through an integrated program of laboratory testing and numerical modeling. Numerous polymer-cement nanocomposites were synthesized as candidate wellbore repair materials using various combinations of base polymers and nanoparticles. Based on tests of bond strength to steel and cement, ductility, stability, flowability, and penetrability in opening of 50 microns and less, we identified Novolac epoxy reinforced with multi-walled carbon nanotubes and/or alumina nanoparticles to be a superior wellbore seal material compared to conventional microfine cements. A system was developed for testing damaged and repaired wellbore specimens comprised of a cement sheathmore » cast on a steel casing. The system allows independent application of confining pressures and casing pressures while gas flow is measured through the specimens along the wellbore axis. Repair with the nanocomposite epoxy base material was successful in dramatically reducing the flow through flaws of various sizes and types, and restoring the specimen comparable to an intact condition. In contrast, repair of damaged specimens with microfine cement was less effective, and the repair degraded with application of stress. Post-test observations confirm the complete penetration and sealing of flaws using the nanocomposite epoxy base material. A number of modeling efforts have supported the material development and testing efforts. We have modeled the steel-repair material interface behavior in detail during slant shear tests, which we used to characterize bond strength of candidate repair materials. A numerical model of the laboratory testing of damaged wellbore specimens was developed. This investigation found that microannulus permeability can satisfactorily be described by a joint model. Finally, a wellbore model has been developed that can be used to evaluate the response of the wellbore system (casing, cement, and microannulus), including the use of either cement or a nanocomposite in the microannulus to represent a repaired system. This wellbore model was successfully coupled with a field-scale model of CO 2 injection, to enable predictions of stress and strains in the wellbore subjected to subsurface changes (i.e. domal uplift) associated with fluid injection.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bohrman, J.S.; Burg, J.R.; Elmore, E.
1988-01-01
Three laboratories participated in an interlaboratory study to evaluate the usefulness of the Chinese hamster V79 cell metabolic cooperation assay to predict the tumor-promoting activity of selected chemical. Twenty-three chemicals of different chemical structures (phorbol esters, barbiturates, phenols, artificial sweeteners, alkanes, and peroxides) were chosen for testing based on in vivo promotion activities, as reported in the literature. Assay protocols and materials were standardized, and the chemicals were coded to facilitate unbiased evaluation. A chemical was tested only once in each laboratory, with one of the three laboratories testing only 15 out of 23 chemicals. Dunnett's test was used formore » statistical analysis. Chemicals were scored as positive (at least two concentration levels statistically different than control), equivocal (only one concentration statistically different), or negative. For 15 chemicals tested in all three laboratories, there was complete agreement among the laboratories for nine chemicals. For the 23 chemicals tested in only two laboratories, there was agreement on 16 chemicals. With the exception of the peroxides and alkanes, the metabolic cooperation data were in general agreement with in vivo data. However, an overall evaluation of the V79 cell system for predicting in vivo promotion activity was difficult because of the organ specificity of certain chemicals and/or the limited number of adequately tested nonpromoting chemicals.« less
Lloyd, C H; Yearn, J A; Cowper, G A; Blavier, J; Vanderdonckt, M
2004-07-01
The setting expansion is an important property for a phosphate-bonded investment material. This research was undertaken to investigate a test that might be suitable for its measurement when used in a Standard. In the 'Casting-Ring Test', the investment sample is contained in a steel ring and expands to displace a precisely positioned pin. Variables with the potential to alter routine reproduction of the value were investigated. The vacuum-mixer model is a production laboratory variable that must not be ignored and for this reason, experiments were repeated using a different vacuum-mixer located at a second test site. Restraint by the rigid ring material increased expansion, while force on the pin reduced it. Expansion was specific to the lining selected. Increased environmental temperature decreased the final value. Expansion was still taking place at a time at which its value might be measured. However, when these factors are set, the reproducibility of values for setting expansion was good at both test sites (coefficient of variation 14%, at most). The results revealed that with the control that is available reliable routine measurement is possible in a Standard test. The inter-laboratory variable, vacuum-mixer model, produced significant differences and it should be the subject of further investigation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Janke, Christopher James; Das, Sadananda; Oyola, Yatsandra
2014-08-01
This report describes work on the successful completion of Milestone M2FT-14OR03100115 (8/20/2014) entitled, “Complete new adsorbent materials for marine testing to demonstrate 4.5 g-U/kg adsorbent”. This effort is part of the Seawater Uranium Recovery Program, sponsored by the U.S. Department of Energy, Office of Nuclear Energy, and involved the development of new adsorbent materials at the Oak Ridge National Laboratory (ORNL) and marine testing at the Pacific Northwest National Laboratory (PNNL). ORNL has recently developed two new families of fiber adsorbents that have demonstrated uranium adsorption capacities greater than 4.5 g-U/kg adsorbent after marine testing at PNNL. One adsorbent wasmore » synthesized by radiation-induced graft polymerization of itaconic acid and acrylonitrile onto high surface area polyethylene fibers followed by amidoximation and base conditioning. This fiber showed a capacity of 4.6 g-U/kg adsorbent in marine testing at PNNL. The second adsorbent was prepared by atom-transfer radical polymerization of t-butyl acrylate and acrylonitrile onto halide-functionalized round fibers followed by amidoximation and base hydrolysis. This fiber demonstrated uranium adsorption capacity of 5.4 g-U/kg adsorbent in marine testing at PNNL.« less
Carbon fiber based composites stress analysis. Experimental and computer comparative studies
NASA Astrophysics Data System (ADS)
Sobek, M.; Baier, A.; Buchacz, A.; Grabowski, Ł.; Majzner, M.
2015-11-01
Composite materials used nowadays for the production of composites are the result of advanced research. This allows assuming that they are among the most elaborate tech products of our century. That fact is evidenced by the widespread use of them in the most demanding industries like aerospace and space industry. But the heterogeneous materials and their advantages have been known to mankind in ancient times and they have been used by nature for millions of years. Among the fibers used in the industry most commonly used are nylon, polyester, polypropylene, boron, metal, glass, carbon and aramid. Thanks to their physical properties last three fiber types deserve special attention. High strength to weight ratio allow the use of many industrial solutions. Composites based on carbon and glass fibers are widely used in the automotive. Aramid fibers ideal for the fashion industry where the fabric made from the fibers used to produce the protective clothing. In the paper presented issues of stress analysis of composite materials have been presented. The components of composite materials and principles of composition have been discussed. Particular attention was paid to the epoxy resins and the fabrics made from carbon fibers. The article also includes basic information about strain measurements performed on with a resistance strain gauge method. For the purpose of the laboratory tests a series of carbon - epoxy composite samples were made. For this purpose plain carbon textile was used with a weight of 200 g/mm2 and epoxy resin LG730. During laboratory strain tests described in the paper Tenmex's delta type strain gauge rosettes were used. They were arranged in specific locations on the surface of the samples. Data acquisition preceded using HBM measurement equipment, which included measuring amplifier and measuring head. Data acquisition was performed using the Easy Catman. In order to verify the results of laboratory tests numerical studies were carried out in a computing environment, Siemens PLM NX 9.0. For this purpose, samples were modeled composite corresponding to real samples. Tests were made for boundary conditions compatible with the laboratory tests boundary conditions.
Akchata, Suman; Lavanya, K; Shivanand, Bhushan
2017-01-01
Context: Decontamination of various working surfaces with sodium pertechnetate minor spillage is essential for maintaining good radiation safety practices as well as for regulatory compliance. Aim: To observe the influences of decontaminating agents and swipe materials on different type of surfaces used in nuclear medicine laboratory work area wet spilled with 99m-technetium (99mTc) sodium pertechnetate. Settings and Design: Lab-simulated working surface materials. Experimental study design. Materials and Methods: Direct decontamination method on dust-free lab simulated new working surfaces [stainless steel, polyvinyl chloride (PVC), Perspex, resin] using four decontaminating agents [tap water, soap water (SW), Radiacwash, and spirit] with four different swipe material [cotton, tissue paper (TP), Whatman paper (WP), adsorbent sheet (AS)] was taken 10 samples (n = 10) for each group. Statistical Analysis: Parametric test two-way analysis of variance is used with significance level of 0.005, was used to evaluate statistical differences between different group of decontaminating agent and swipe material, and the results are expressed in mean ± SD. Results: Decontamination factor is calculated after five cleaning for each group. A total of 160 samples result calculated using four decontaminating agent (tap water, SW, Radiacwash, and spirit), four swipe material (cotton, TP, WP, and AS) for commonly used surface (stainless steel, PVC, Perspex, resin) using direct method by 10 samples (n = 10) for each group. Conclusions: Tap water is the best decontaminating agent compared with SW, Radiac wash and spirit for the laboratory simulated stainless steel, PVC, and Perspex surface material, whereas in case of resin surface material, SW decontaminating agent is showing better effectiveness. Cotton is the best swipe material compared to WP-1, AS and TP for the stainless steel, PVC, Perspex, and resin laboratory simulated surface materials. Perspex and stainless steel are the most suitable and recommended laboratory surface material compared to PVC and resin in nuclear medicine. Radiacwash may show better result for 99mTc labelled product and other radionuclide contamination on the laboratory working surface area. PMID:28680198
2002-10-11
KENNEDY SPACE CENTER, FLA. -- This 100-pound Mundrabilla meteorite sample is being studied in Wyle Laboratory's Nondestructive Testing Laboratory at KSC. The one-of-a-kind meteorite was found 36 years ago in Australia and is on loan to Marshall Space Flight Center (MSFC) from the Smithsonian Institution's National Museum of Natural History. Dr. Donald Gillies, discipline scientist for materials science at MSFC's Microgravity Science and Applications Department, is the Principal Investigator. The studies may help provide the science community and industry with fundamental knowledge for use in the design of advanced materials.
2002-10-11
KENNEDY SPACE CENTER, FLA. -- This 100-pound Mundrabilla meteorite sample is being studied in Wyle Laboratory's Nondestructive Testing Laboratory at KSC. The one-of-a-kind meteorite was found 36 years ago in Australia and is on loan to Marshall Space Flight Center (MSFC) from the Smithsonian Institution's National Museum of Natural History. Dr. Donald Gillies, discipline scientist for materials science at MSFC's Microgravity Science and Applications Department, is the Principal Investigator. The studies may help provide the science community and industry with fundamental knowledge for use in the design of advanced materials.
NASA Astrophysics Data System (ADS)
Kanty, Piotr; Rybak, Jarosław; Stefaniuk, Damian
2017-10-01
This paper presents the results of laboratory testing of organic soil-cement samples are presented in the paper. The research program continues previously reported the authors’ experiences with cement-fly ash-soil sample testing. Over 100 of compression and a dozen of tension tests have been carried out altogether. Several samples were waiting for failure test for over one year after they were formed. Several factors, like: the large amount of the tested samples, a long observation time, carrying out the tests in complex cycles of loading and the possibility of registering the loads and deformation in the axial and lateral direction - have made it possible to take into consideration numerous interdependencies, three of which have been presented in this work: the increments of compression strength, the stiffness of soil-cement in relation to strength and the tensile strength. Compressive strength, elastic modulus and tensile resistance of cubic samples were examined. Samples were mixed and stored in the laboratory conditions. Further numerical analysis in the Finite Element Method numerical code Z_Soil, were performed on the basis of laboratory test results. Computations prove that cement-based stabilization of organic soil brings serious risks (in terms of material capacity and stiffness) and Deep Soil Mixing technology should not be recommended for achieving it. The numerical analysis presented in the study below includes only one type of organic and sandy soil and several possible geometric combinations. Despite that, it clearly points to the fact that designing the DSM columns in the organic soil may be linked with a considerable risk and the settlement may reach too high values. During in situ mixing, the organic material surrounded by sand layers surely mixes with one another in certain areas. However, it has not been examined and it is difficult to assume such mixing already at the designing stage. In case of designing the DSM columns which goes through a thin layer of organic soil it is recommended to carry out each time the core drilling which checks the degree of material mixing and their strength.
High-temperature elastic-plastic and creep properties for SA533 Grade B Class I and SA508 materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reddy, G.B.; Ayres, D.J.
1982-12-01
High temperature elastic-plastic and creep properties are presented for SA533 Grade B Class I and SA508 Class II materials. These properties are derived from tests conducted at Combustion Engineering Material and Metallurgical Laboratories and cover the temperature range of 70/sup 0/F to 1200/sup 0/F.
Spallation Neutron Source Materials Studies
NASA Astrophysics Data System (ADS)
Sommer, W. F.
1998-04-01
Operation of accelerator facilities such as Los Alamos Neutron Science Center (LANSCE), ISIS at Rutherford Appleton Laboratory, the Swiss Institute Neutron Source (SINQ) at Paul Scherrer Institute, and others has provided valuable information on materials performance in high energy particle beams and high energy neutron environments. The Accelerator Production of Tritium (APT) project is sponsoring an extensive series of tests on the effect of spallation neutron source environments to physical and mechanical properties of candidate materials such as nickel-based alloys, stainless steel alloys, aluminum alloys and solid target materials such as tungsten. Measurements of corrosion rates of these candidate materials during irradiation and while in contact with flowing coolant water are being made. The APT tests use the irradiation facility in the beam stop area of the LANSCE accelerator using 800 MeV protons as well as the neutron flux-spectrum generated as these protons interact with targets. The initial irradiations were completed in summer 1997, exposing materials to a fluence approaching 4-6 x 10^21 protons/cm^2. Sample retrieval is now underway. Mechanical properties measurements are being conducted at several laboratories. Studies on components used in service have also been initiated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coates, Cameron W; Eisele, Gerhard R
2011-01-01
The Russian Federation (RF) is committed to implementing a comprehensive drug testing program under its Personnel Reliability Program (PRP) for military personnel involved in handling sensitive nuclear materials. This commitment leads to a number of mandatory requirements for the laboratory conducting the confirmation testing to ensure the legitimacy and integrity of the testing process. These requirements are established by the RF Duma to ensure that individuals conducting these tests have adequate training, certifications, and experience to conduct narcotic confirmation tests. This paper describes the facility requirements and personnel qualifications needed for conducting comprehensive drug abuse confirmation testing. Details regarding themore » personnel training and laboratory experience in the theory and practice of analytical forensic toxicology of drugs of abuse will be presented, as well as the facility requirements for the laboratory conducting such tests. Chain-of-custody, from sample receipt through completion of testing, reporting of results, and continuing until final disposition of specimens will be addressed.« less
Laboratory Testing of Waste Isolation Pilot Plant Surrogate Waste Materials
NASA Astrophysics Data System (ADS)
Broome, S.; Bronowski, D.; Pfeifle, T.; Herrick, C. G.
2011-12-01
The Waste Isolation Pilot Plant (WIPP) is a U.S. Department of Energy geological repository for the permanent disposal of defense-related transuranic (TRU) waste. The waste is emplaced in rooms excavated in the bedded Salado salt formation at a depth of 655 m below the ground surface. After emplacement of the waste, the repository will be sealed and decommissioned. WIPP Performance Assessment modeling of the underground material response requires a full and accurate understanding of coupled mechanical, hydrological, and geochemical processes and how they evolve with time. This study was part of a broader test program focused on room closure, specifically the compaction behavior of waste and the constitutive relations to model this behavior. The goal of this study was to develop an improved waste constitutive model. The model parameters are developed based on a well designed set of test data. The constitutive model will then be used to realistically model evolution of the underground and to better understand the impacts on repository performance. The present study results are focused on laboratory testing of surrogate waste materials. The surrogate wastes correspond to a conservative estimate of the degraded containers and TRU waste materials after the 10,000 year regulatory period. Testing consists of hydrostatic, uniaxial, and triaxial tests performed on surrogate waste recipes that were previously developed by Hansen et al. (1997). These recipes can be divided into materials that simulate 50% and 100% degraded waste by weight. The percent degradation indicates the anticipated amount of iron corrosion, as well as the decomposition of cellulosics, plastics, and rubbers. Axial, lateral, and volumetric strain and axial and lateral stress measurements were made. Two unique testing techniques were developed during the course of the experimental program. The first involves the use of dilatometry to measure sample volumetric strain under a hydrostatic condition. Bulk moduli of the samples measured using this technique were consistent with those measured using more conventional methods. The second technique involved performing triaxial tests under lateral strain control. By limiting the lateral strain to zero by controlling the applied confining pressure while loading the specimen axially in compression, one can maintain a right-circular cylindrical geometry even under large deformations. This technique is preferred over standard triaxial testing methods which result in inhomogeneous deformation or "barreling". Manifestations of the inhomogeneous deformation included non-uniform stress states, as well as unrealistic Poisson's ratios (> 0.5) or those that vary significantly along the length of the specimen. Zero lateral strain controlled tests yield a more uniform stress state, and admissible and uniform values of Poisson's ratio. Hansen, F.D., Knowles, M.K., et al. 1997. Description and Evaluation of a Mechanistically Based Conceptual Model for Spall. SAND97-1369. Sandia National Laboratories, Albuquerque. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.
Cryogenic Moisture Analysis of Spray-On Foam Insulation (SOFI)
NASA Technical Reports Server (NTRS)
2008-01-01
The NASA Cryogenics Test Laboratory at Kennedy Space Center conducted long-term testing of SOFI materials under actual-use cryogenic conditions. The lab tested NCFI 24-124 (acreage foam), BX-265 (close-out foam, including intertank flange and bipod areas), and a potential alternate material, NCFI 27-68 (acreage foam with the flame retardant removed). Specimens of all three materials were placed at a site that simulated aging (the Vehicle Assembly Building [VAB]) and a site that simulated weathering (Atmospheric Exposure Test Site [beach site]). After aging/ weathering intervals of 3, 6, and 12 months, the samples were retrieved and tested for their ability to absorb moisture under conditions similar to those experienced by the Space Shuttle External Tank (ET) during the loading of cryogenic propellants.
Ultra-Low Level Plutonium Isotopes in the NIST SRM 4355A (Peruvian Soil-1)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Inn, Kenneth G.; LaRosa, Jerome; Nour, Svetlana
2009-05-31
For more than 20 years, countries and their agencies which monitor discharge sites and storage facilities have relied on the National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 4355 Peruvian Soil reference material. Its low fallout contamination makes it an ideal soil blank for measurements associated with terrestrial pathway to man studies. Presently, SRM 4355 is out of stock, and a new batch of the Peruvian soil is currently under development as future NIST SRM 4355A. Both environmental radioanalytical laboratories and mass spectrometry communities will benefit from this SRM. The former must assess their laboratory contamination andmore » measurement detection limits by measurement of blank sample material. The Peruvian Soil is so low in anthropogenic radionuclides that it is a suitable virtual blank. On the other hand, mass spectrometric laboratories have high sensitivity instruments that are capable of quantitative isotopic measurements at low plutonium levels of the SRM 4355 (first Peruvian Soil SRM) that provided the mass spectrometric community with the calibration, quality control, and testing material needed for methods development, and legal defensibility. The quantification of the ultra-low plutonium content in the SRM 4355A was a considerable challenge for the mass spectrometric laboratories. Careful blank control and correction, isobaric interferences, instrument stability, peak assessment, and detection assessment were necessary. Furthermore, a systematic statistical evaluation of the measurement results and considerable discussions with the mass spectroscopy metrologists were needed to derive the certified values and uncertainties. SRM 4355A will provide the mass spectrometric community with the quality control and testing material needed for higher sensitivity methods development, and legal defensibility.« less
[External quality control system in medical microbiology and parasitology in the Czech Republic].
Slosárek, M; Petrás, P; Kríz, B
2004-11-01
The External Quality Control System (EQAS) of laboratory activities in medical microbiology and parasitology was implemented in the Czech Republic in 1993 with coded sera samples for diagnosis of viral hepatitis and bacterial strains for identification distributed to first participating laboratories. The number of sample types reached 31 in 2003 and the number of participating laboratories rised from 79 in 1993 to 421 in 2003. As many as 15.130 samples were distributed to the participating laboratories in 2003. Currently, almost all microbiology and parasitology laboratories in the Czech Republic involved in examination of clinical material participate in the EQAS. Based on the 11-year experience gained with the EQAS in the Czech Republic, the following benefits were observed: higher accuracy of results in different tests, standardisation of methods and the use of most suitable test kits.
Effects of the weld thermal cycle on the microstructure of alloy 690
NASA Astrophysics Data System (ADS)
Tuttle, James R.
Alloy 690 has been introduced as a material for use as the heat exchanger tubes in the steam generators (SGs) of pressurised water reactor (PWR) nuclear power plant. Its immediate predecessor, alloy 600, suffered from a number of degradation modes and another alternative, alloy 800, has also had in-service problems. In laboratory tests, alloy 690 in both mill annealed (MA) and special thermally treated (STT) condition has shown a high degree of resistance to degradation in simulated PWR primary side environments and other test media.Limited research has previously been undertaken to investigate the effects of welding on alloy 690, when the material is used in SG applications. It was deemed important to increase knowledge in this area since fabrication of PWR SGs involves gas tungsten arc welding (GTAW) of the heat exchanger tubes to a clad tubeplate. For this research investigation welded samples of alloy 690 have been produced in the laboratory using a range of thermal cycles based around recommended weld parameters for SG fabrication. These samples have been compared with archive welds from PWR SG manufacturers. A number of welds incorporating alloy 600 and a number using alloy 800 tubing material have also been fabricated in the laboratory for comparative purposes. Two experimental melts have been produced to study the effects of Nb substitution for Ti in alloy 690 type materials.Welded and unwelded specimens have been studied, analysed and tested using a variety of methods and techniques. A method of metallographic sample preparation for transmission electron microscope (TEM) thin foil specimens has been developed and documented which ensures foil perforation in a specific region. The effects of Nb substitution for Ti have been discussed. Chemical balances and microstructures in the fusion zone of welds manufactured from alloy 690 tubing incorporating alloy 82 weld consumable have been shown to be non-ideal. Within the heat affected zone (HAZ) of both laboratory produced and archive welds the microstructures have been identified as detrimentally altered from the STT condition original tubing material(s). A number of conclusions have been drawn and recommendations have been made for future work.
NASA Technical Reports Server (NTRS)
Jassowski, Donald M.
1993-01-01
Propellants, chamber materials, and processes for fabrication of small high performance radiation cooled liquid rocket engines were evaluated to determine candidates for eventual demonstration in flight-type thrusters. Both storable and cryogenic propellant systems were considered. The storable propellant systems chosen for further study were nitrogen tetroxide oxidizer with either hydrazine or monomethylhydrazine as fuel. The cryogenic propellants chosen were oxygen with either hydrogen or methane as fuel. Chamber material candidates were chemical vapor deposition (CVD) rhenium protected from oxidation by CVD iridium for the chamber hot section, and film cooled wrought platinum-rhodium or regeneratively cooled stainless steel for the front end section exposed to partially reacted propellants. Laser diagnostics of the combustion products near the hot chamber surface and measurements at the surface layer were performed in a collaborative program at Sandia National Laboratories, Livermore, CA. The Material Sample Test Apparatus, a laboratory system to simulate the combustion environment in terms of gas and material temperature, composition, and pressure up to 6 Atm, was developed for these studies. Rocket engine simulator studies were conducted to evaluate the materials under simulated combustor flow conditions, in the diagnostic test chamber. These tests used the exhaust species measurement system, a device developed to monitor optically species composition and concentration in the chamber and exhaust by emission and absorption measurements.
Modified Composite Materials Workshop
NASA Technical Reports Server (NTRS)
Dicus, D. L. (Compiler)
1978-01-01
The reduction or elimination of the hazard which results from accidental release of graphite fibers from composite materials was studied at a workshop. At the workshop, groups were organized to consider six topics: epoxy modifications, epoxy replacement, fiber modifications, fiber coatings and new fibers, hybrids, and fiber release testing. Because of the time required to develop a new material and acquire a design data base, most of the workers concluded that a modified composite material would require about four to five years of development and testing before it could be applied to aircraft structures. The hybrid working group considered that some hybrid composites which reduce the risk of accidental fiber release might be put into service over the near term. The fiber release testing working group recommended a coordinated effort to define a suitable laboratory test.
MTR CONTROL ROOM WITH CONTROL CONSOLE AND STATUS READOUTS ALONG ...
MTR CONTROL ROOM WITH CONTROL CONSOLE AND STATUS READOUTS ALONG WALL. WORKERS MAKE ELECTRICAL AND OTHER CONNECTIONS. INL NEGATIVE NO. 4289. Unknown Photographer, 2/26/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
SOUTH WING, TRA661. SOUTH SIDE. CAMERA FACING NORTH. MTR HIGH ...
SOUTH WING, TRA-661. SOUTH SIDE. CAMERA FACING NORTH. MTR HIGH BAY BEYOND. INL NEGATIVE NO. HD46-45-3. Mike Crane, Photographer, 4/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR HEAT EXCHANGER BUILDING, TRA644. WORKERS ARE INSTALLING HEAT EXCHANGER ...
ETR HEAT EXCHANGER BUILDING, TRA-644. WORKERS ARE INSTALLING HEAT EXCHANGER PIPING. INL NEGATIVE NO. 56-3122. Jack L. Anderson, Photographer, 9/21/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
MTR AND ETR COMPLEXES. CAMERA FACING EASTERLY TOWARD CHEMICAL PROCESSING ...
MTR AND ETR COMPLEXES. CAMERA FACING EASTERLY TOWARD CHEMICAL PROCESSING PLANT. MTR AND ITS ATTACHMENTS IN FOREGROUND. ETR BEYOND TO RIGHT. INL NEGATIVE NO. 56-4100. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR COMPRESSOR BUILDING, TRA643. COMPRESSORS AND OTHER EQUIPMENT INSTALLED. METAL ...
ETR COMPRESSOR BUILDING, TRA-643. COMPRESSORS AND OTHER EQUIPMENT INSTALLED. METAL ROOF AND CONCRETE BLOCK WALLS. INL NEGATIVE NO. 61-4536. Unknown Photographer, ca. 1961. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
DOT National Transportation Integrated Search
2016-04-01
While structural engineering deals with mostly homogeneous manmade materials : (e.g., concrete and steel), geotechnical engineering typically involves highly varied : natural materials (e.g., soil and rock). As a result, high variance of the resistan...
Solar Heating Systems: Student Manual.
ERIC Educational Resources Information Center
Green, Joanne; And Others
This Student Manual for a Solar Heating System curriculum contains 22 units of instructional materials for students to use in a course or courses on solar heating systems (see note). For each unit (task), objectives, assignment sheets, laboratory assignments, information sheets, checkpoints (tests), and job sheets are provided. Materials are set…
Thermal Protection Materials Development
NASA Technical Reports Server (NTRS)
Selvaduray, Guna; Cox, Michael
1998-01-01
The main portion of this contract year was spent on the development of materials for high temperature applications. In particular, thermal protection materials were constantly tested and evaluated for thermal shock resistance, high-temperature dimensional stability, and tolerance to hostile environmental effects. The analytical laboratory at the Thermal Protection Materials Branch (TPMB), NASA-Ames played an integral part in the process of materials development of high temperature aerospace applications. The materials development focused mainly on the determination of physical and chemical characteristics of specimens from the various research programs.
ERIC Educational Resources Information Center
Corsepius, Nicholas C.; DeVore, Thomas C.; Reisner, Barbara A.; Warnaar, Deborah L.
2007-01-01
A laboratory exercise was developed by using variable temperature powder X-ray diffraction (XRD) to determine [alpha] for MgO (periclase)and was tested in the Applied Physical Chemistry and Materials Characterization Laboratories at James Madison University. The experiment which was originally designed to provide undergraduate students with a…
Yoshida, Mitsuru
2014-08-01
Japanese food self-sufficiency was only 39% on the basis of kcal in 2012, so Japan relies heavily on imported food. Hence the necessity of having international rules on the regulation of food contaminants is important especially for countries like Japan that depend on food imports. A One-Stop-Testing system is desired, in which the test result obtained from a single testing laboratory is accepted as valid worldwide. To establish this system, laboratory accreditation under international standards is a necessary step. Furthermore, the importance of supply of reference materials for internal quality control and proficiency testing for external quality control of each laboratory's analytical system is reviewed in connection with the experience of radioactive nuclide contamination resulting from the Fukushima nuclear power plant accident in March 2011. © 2013 Society of Chemical Industry.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buchholz, Stuart A.
This memorandum documents laboratory thermomechanical triaxial strength testing of Waste Isolation Pilot Plant (WIPP) clean salt. The limited study completed independent, adjunct laboratory tests in the United States to assist in validating similar testing results being provided by the German facilities. The testing protocol consisted of completing confined triaxial, constant strain rate strength tests of intact WIPP clean salt at temperatures of 25°C and 100°C and at multiple confining pressures. The stratigraphy at WIPP also includes salt that has been labeled “argillaceous.” The much larger test matrix conducted in Germany included both the so-called clean and argillaceous salts. When combined,more » the total database of laboratory results will be used to develop input parameters for models, assess adequacy of existing models, and predict material behavior. These laboratory studies are also consistent with the goals of the international salt repository research program. The goal of this study was to complete a subset of a test matrix on clean salt from the WIPP undertaken by German research groups. The work was performed at RESPEC in Rapid City, South Dakota. A rigorous Quality Assurance protocol was applied, such that corroboration provides the potential of qualifying all of the test data gathered by German research groups.« less
Characterization of Microporous Insulation, Microsil
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, R.
Microsil microporous insulation has been characterized by Lawrence Livermore National Laboratory for possible use in structural and thermal applications in the DPP-1 design. Qualitative test results have provided mechanical behavioral characteristics for DPP-1 design studies and focused on the material behavioral response to being crushed, cyclically loaded, and subjected to vibration for a confined material with an interference fit or a radial gap. Quantitative test results have provided data to support the DPP-1 FEA model analysis and verification and were used to determine mechanical property values for the material under a compression load. The test results are documented within thismore » report.« less
Numerical simulation of mechanical properties tests of tungsten mud waste geopolymer
NASA Astrophysics Data System (ADS)
Paszek, Natalia; Krystek, Małgorzata
2018-03-01
Geopolymers are believed to become in the future an environmental friendly alternative for the concrete. The low CO2 emission during the production process and the possibility of ecological management of the industrial wastes are mentioned as main advantages of geopolymers. The main drawback, causing problems with application of geopolymers as a building material is the lack of the theoretical material model. Indicated problem is being solved now by the group of scientists from the Silesian University of Technology. The series of laboratory tests are carried out within the European research project REMINE. The paper introduces the numerical analyses of tungsten mud waste geopolymer samples which have been performed in the Atena software on the basis of the laboratory tests. Numerical models of bended and compressed samples of different shapes are presented in the paper. The results obtained in Atena software were compared with results obtained in Abaqus and Mafem3D software.
Palm-Based Standard Reference Materials for Iodine Value and Slip Melting Point
Tarmizi, Azmil Haizam Ahmad; Lin, Siew Wai; Kuntom, Ainie
2008-01-01
This work described study protocols on the production of Palm-Based Standard Reference Materials for iodine value and slip melting point. Thirty-three laboratories collaborated in the inter-laboratory proficiency tests for characterization of iodine value, while thirty-two laboratories for characterization of slip melting point. The iodine value and slip melting point of palm oil, palm olein and palm stearin were determined in accordance to MPOB Test Methods p3.2:2004 and p4.2:2004, respectively. The consensus values and their uncertainties were based on the acceptability of statistical agreement of results obtained from collaborating laboratories. The consensus values and uncertainties for iodine values were 52.63 ± 0.14 Wijs in palm oil, 56.77 ± 0.12 Wijs in palm olein and 33.76 ± 0.18 Wijs in palm stearin. For the slip melting points, the consensus values and uncertainties were 35.6 ± 0.3 °C in palm oil, 22.7 ± 0.4 °C in palm olein and 53.4 ± 0.2 °C in palm stearin. Repeatability and reproducibility relative standard deviations were found to be good and acceptable, with values much lower than that of 10%. Stability of Palm-Based Standard Reference Materials remained stable at temperatures of −20 °C, 0 °C, 6 °C and 24 °C upon storage for one year. PMID:19609396
NASA Astrophysics Data System (ADS)
Abdelmalak, M. M.; Bulois, C.; Mourgues, R.; Galland, O.; Legland, J.-B.; Gruber, C.
2016-08-01
Cohesion and friction coefficient are fundamental parameters for scaling brittle deformation in laboratory models of geological processes. However, they are commonly not experimental variable, whereas (1) rocks range from cohesion-less to strongly cohesive and from low friction to high friction and (2) strata exhibit substantial cohesion and friction contrasts. This brittle paradox implies that the effects of brittle properties on processes involving brittle deformation cannot be tested in laboratory models. Solving this paradox requires the use of dry granular materials of tunable and controllable brittle properties. In this paper, we describe dry mixtures of fine-grained cohesive, high friction silica powder (SP) and low-cohesion, low friction glass microspheres (GM) that fulfill this requirement. We systematically estimated the cohesions and friction coefficients of mixtures of variable proportions using two independent methods: (1) a classic Hubbert-type shear box to determine the extrapolated cohesion (C) and friction coefficient (μ), and (2) direct measurements of the tensile strength (T0) and the height (H) of open fractures to calculate the true cohesion (C0). The measured values of cohesion increase from 100 Pa for pure GM to 600 Pa for pure SP, with a sub-linear trend of the cohesion with the mixture GM content. The two independent cohesion measurement methods, from shear tests and tension/extensional tests, yield very similar results of extrapolated cohesion (C) and show that both are robust and can be used independently. The measured values of friction coefficients increase from 0.5 for pure GM to 1.05 for pure SP. The use of these granular material mixtures now allows testing (1) the effects of cohesion and friction coefficient in homogeneous laboratory models and (2) testing the effect of brittle layering on brittle deformation, as demonstrated by preliminary experiments. Therefore, the brittle properties become, at last, experimental variables.
Satisfying regulatory and accreditation requirements for quality control.
Ehrmeyer, Sharon S
2013-03-01
The Clinical Laboratory Improvement Amendments of 1988 (CLIA) requires all US clinical laboratories that test "materials derived from the human body for the purpose of providing information for the diagnosis, prevention, or treatment of any disease..." to be regulated. The CLIA mandates are site neutral; based on test complexity; and focus on the three phases of the testing process (preanalytical, analytical, and postanalytical). Many testing sites choose to meet the CLIA requirements by following the testing standards of a professional accreditation organization deemed by the Centers for Medicare and Medicaid Services. The three principal organizations are The Joint Commission, the College of American Pathologists, and COLA. Copyright © 2013 Elsevier Inc. All rights reserved.
Fabrication and Tests of M240 Machine Gun Barrels Lined with Stellite 25
2016-04-01
ARL-TR-7662 ● APR 2016 US Army Research Laboratory Fabrication and Tests of M240 Machine Gun Barrels Lined with Stellite 25...Fabrication and Tests of M240 Machine Gun Barrels Lined with Stellite 25 by William S de Rosset and Sean Fudger Weapons and Materials Research...
Removal of phosphorus using AMD-treated lignocellulosic material
James S. Han; Soo-Hong Min; Yeong-Kwan Kim
2005-01-01
Excess nutrients, including phosphorus, can cause eutrophication in surface water and reservoirs. We tested the phosphate removal capacity of juniper fiber through isotherm, kinetic, column, and field tests. Heavy metals from an acid mine drainage (AMD) site were precipitated on the surface ofjuniper fiber. The modified fiber was tested in laboratory- caled batch and...
DOT National Transportation Integrated Search
2005-02-01
Accelerated load testing of paved and unpaved roads is the application of a large number of load repetitions in a short period of time. This type of testing is an economic way to determine the behavior of roads and compare different materials, struct...
Spira, Thomas; Lindegren, Mary Lou; Ferris, Robert; Habiyambere, Vincent; Ellerbrock, Tedd
2009-06-01
The expansion of HIV/AIDS care and treatment in resource-constrained countries, especially in sub-Saharan Africa, has generally developed in a top-down manner. Further expansion will involve primary health centers where human and other resources are limited. This article describes the World Health Organization/President's Emergency Plan for AIDS Relief collaboration formed to help scale up HIV services in primary health centers in high-prevalence, resource-constrained settings. It reviews the contents of the Operations Manual developed, with emphasis on the Laboratory Services chapter, which discusses essential laboratory services, both at the center and the district hospital level, laboratory safety, laboratory testing, specimen transport, how to set up a laboratory, human resources, equipment maintenance, training materials, and references. The chapter provides specific information on essential tests and generic job aids for them. It also includes annexes containing a list of laboratory supplies for the health center and sample forms.
A flammability study of thin plastic film materials
NASA Technical Reports Server (NTRS)
Skinner, S. Ballou
1990-01-01
The Materials Science Laboratory at the Kennedy Space Center presently conducts flammability tests on thin plastic film materials by using a small needle rake method. Flammability data from twenty-two thin plastic film materials were obtained and cross-checked by using three different testing methods: (1) the presently used small needle rake; (2) the newly developed large needle rake; and (3) the previously used frame. In order to better discern the melting-burning phenomenon of thin plastic film material, five additional specific experiments were performed. These experiments determined the following: (1) the heat sink effect of each testing method; (2) the effect of the burn angle on the burn length or melting/shrinkage length; (3) the temperature profile above the ignition source; (4) the melting point and the fire point of each material; and (5) the melting/burning profile of each material via infrared (IR) imaging. The results of these experimentations are presented.
Flight- and ground-test correlation study of BMDO SDS materials: Phase 1 report
NASA Technical Reports Server (NTRS)
Chung, Shirley Y.; Brinza, David E.; Minton, Timothy K.; Stiegman, Albert E.; Kenny, James T.; Liang, Ranty H.
1993-01-01
The NASA Evaluation of Oxygen Interactions with Materials-3 (EOIM-3) experiment served as a test bed for a variety of materials that are candidates for Ballistic Missile Defense Organization (BMDO) space assets. The materials evaluated on this flight experiment were provided by BMDO contractors and technology laboratories. A parallel ground exposure evaluation was conducted using the FAST atomic-oxygen simulation facility at Physical Sciences, Inc. The EOIM-3 materials were exposed to an atomic oxygen fluence of approximately 2.3 x 10(exp 2) atoms/sq. cm. The ground-exposed materials' fluence of 2.0 - 2.5 x 10(exp 2) atoms/sq. cm permits direct comparison of ground-exposed materials' performance with that of the flight-exposed specimens. The results from the flight test conducted aboard STS-46 and the correlative ground exposure are presented in this publication.
Collaborative Testing in Practical Laboratories: An Effective Teaching-Learning Method in Histology.
Guo, Yuping; Li, Enzhong
2016-01-01
This article presents an experimental teaching and learning program used in histology with first-year students in the second term in the Faculty of Biology at Huanghuai University, China. Eighty-six students were divided randomly into two groups (n=43 per group). Tests were conducted at the end of each practical laboratory (10 laboratories in total) in which collaborative testing was used in the experimental group and traditional testing in the control group. To assess achievement, a final examination in histology was carried out at the end of the course. To determine students' attitude to the teaching styles, a questionnaire survey was conducted at the end of the term. Results showed that students preferred the collaborative testing format. In the experimental group, students' scores were significantly higher than those of students in the control group in final examinations. These findings indicate that collaborative testing enhances student learning and understanding of the material taught, and suggest that collaborative testing is an effective teaching-learning method in histology.
NASA Astrophysics Data System (ADS)
Ioannou, Ioannis; Theodoridou, Magdalini; Modestou, Sevasti; Fournari, Revecca; Dagrain, Fabrice
2013-04-01
The characterization of material properties and the diagnosis of their state of weathering and conservation are three of the most important steps in the field of cultural heritage preservation. Several standardised experimental methods exist, especially for determining the material properties and their durability. However, they are limited in their application by the required size of test specimens and the controlled laboratory conditions needed to undertake the tests; this is especially true when the materials under study constitute immovable parts of heritage structures. The current use of other advanced methods of analysis, such as imaging techniques, in the aforementioned field of research offers invaluable results. However, these techniques may not always be accessible to the wider research community due to their complex nature and relatively high cost of application. This study presents innovative applications of two recently developed cutting techniques; the portable Drilling Resistance Measuring System (DRMS) and the scratch tool. Both methods are defined as micro-destructive, since they only destroy a very small portion of sample material. The general concept of both methods lies within the forces needed to cut a material by linear (scratch tool) or rotational (DRMS) cutting action; these forces are related to the mechanical properties of the material and the technological parameters applied on the tool. Therefore, for a given testing configuration, the only parameter influencing the forces applied is the strength of the material. These two techniques have been used alongside a series of standardised laboratory tests aiming at the correlation of various stone properties (density, porosity, dynamic elastic modulus and uniaxial compressive strength). The results prove the potential of both techniques in assessing the uniaxial compressive strength of stones. The scratch tool has also been used effectively to estimate the compressive strength of mud bricks. It therefore follows that both micro-destructive techniques may prove useful in the physico-mechanical characterization of materials which demand in-situ measurements or allow very limited sampling. Moreover, both techniques have been used, for the first time, to map the distribution of salts in building stone in the laboratory; micro-drilling was also applied in the same context in-situ. The results of the laboratory tests performed on limestone impregnated with sodium and magnesium sulfate confirm that both the scratch tool and the DRMS may successfully detect the location of the salt front, as they respond to pore clogging by salt crystals by providing increased scratching/drilling resistance values. Drilling and scratching of duplicate samples treated with a hydrophobic product show the sensitivity of both techniques as they clearly detect changes to the salt front location (i.e. cryptoflorescence) caused by surface treatments. Both techniques were also successful in highlighting the difference in the crystallisation location and pattern of magnesium sulphate and sodium chloride. In-situ application of the micro-drilling test demonstrated its potential for use in the assessment of masonry salt weathering; the results suggest that this technique may, in fact, be useful as a preventive measure against salt damage. Last but not least, both aforementioned novel micro-destructive techniques have been used to assess the effectiveness of commercially available consolidants. The results of the scratch tool have also been utilised to develop a tomography image of the samples under test. Scratching tomography may potentially be combined with in-situ micro-drilling tests to evaluate the effectiveness of consolidation treatments applied on monuments and historic buildings.
ETRMTR MECHANICAL SERVICES BUILDING, TRA653. CAMERA FACING NORTHWEST AS BUILDING ...
ETR-MTR MECHANICAL SERVICES BUILDING, TRA-653. CAMERA FACING NORTHWEST AS BUILDING WAS NEARLY COMPLETE. INL NEGATIVE NO. 57-3653. K. Mansfield, Photographer, 7/22/1957 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Ford Festiva center impacts with a narrow fixed object (rigid pole) : resource materials
DOT National Transportation Integrated Search
1995-08-01
This document contains the results from five crash tests conducted at the Federal Outdoor Impact Laboratory (FOIL) located at the Turner-Fairbank Highway Research Center in McLean, Virginia. The crash tests involved five Ford Festiva two-door sedans,...
FAST CHOPPER BUILDING, TRA665. DETAIL OF STEEL DOOR ENTRY TO ...
FAST CHOPPER BUILDING, TRA-665. DETAIL OF STEEL DOOR ENTRY TO LOWER LEVEL. CAMERA FACING NORTH. INL NEGATIVE NO. HD42-1. Mike Crane, Photographer, 3/2004 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Quevauviller, P; Bennink, D; Bøwadt, S
2001-05-01
It is now well recognised that the quality control (QC) of all types of analyses, including environmental analyses depends on the appropriate use of reference materials. One of the ways to check the accuracy of methods is based on the use of Certified Reference Materials (CRMs), whereas other types of (not certified) Reference Materials (RMs) are used for routine quality control (establishment of control charts) and interlaboratory testing (e.g. proficiency testing). The perception of these materials, in particular with respect to their production and use, differs widely according to various perspectives (e.g. RM producers, routine laboratories, researchers). This review discusses some critical aspects of RM use and production for the QC of environmental analyses and describes the new approach followed by the Measurements & Testing Generic Activity (European Commission) to tackle new research and production needs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carla Miller; Mary Adamic; Stacey Barker
Traditionally, IAEA inspectors have focused on the detection of nuclear indicators as part of infield inspection activities. The ability to rapidly detect and identify chemical as well as nuclear signatures can increase the ability of IAEA inspectors to detect undeclared activities at a site. Identification of chemical indicators have been limited to use in the analysis of environmental samples. Although IAEA analytical laboratories are highly effective, environmental sample processing does not allow for immediate or real-time results to an IAEA inspector at a facility. During a complementary access inspection, under the Additional Protocol, the use of fieldable technologies that canmore » quickly provide accurate information on chemicals that may be indicative of undeclared activities can increase the ability of IAEA to effectively and efficiently complete their mission. The Complementary Access Working Group (CAWG) is a multi-laboratory team with members from Brookhaven National Laboratory, Idaho National Laboratory, Los Alamos National Laboratory, and Sandia National Laboratory. The team identified chemicals at each stage of the nuclear fuel cycle that may provide IAEA inspectors with indications that proliferation activities may be occurring. The group eliminated all indicators related to equipment, technology and training, developing a list of by-products/effluents, non-nuclear materials, nuclear materials, and other observables. These proliferation indicators were prioritized based on detectability from a conduct of operations (CONOPS) perspective of a CA inspection (for example, whether an inspector actually can access the S&O or whether it is in process with no physical access), and the IAEA’s interest in the detection technology in conjunction with radiation detectors. The list was consolidated to general categories (nuclear materials from a chemical detection technique, inorganic chemicals, organic chemicals, halogens, and miscellaneous materials). The team then identified commercial off the shelf (COTS) chemical detectors that may detect the chemicals of interest. Three chemical detectors were selected and tested both in laboratory settings and in field operations settings at Idaho National Laboratory. The instruments selected are: Thermo Scientific TruDefender FT (FTIR), Thermo Scientific FirstDefender RM (Raman), and Bruker Tracer III SD (XRF). Functional specifications, operability, and chemical detectability, selectivity, and limits of detection were determined. Results from the laboratory and field tests will be presented. This work is supported by the Next Generation Safeguards Initiative, Office of Nonproliferation and International Security, National Nuclear Security Administration.« less
Proppant flowback control additives
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nguyen, P.D.; Weaver, J.D.; Parker, M.A.
1996-12-31
This paper describes the laboratory and field development of thermoplastic film materials used to reduce proppant flowback that can occur after fracturing treatments. The paper provides a summary of flowback mechanism theories and laboratory tests comparing flowback tendency for various types of treating procedures and materials. Some of these materials include angular proppant, proppant/fiber mixtures, and proppant with film strips tested over a wide range of temperature, closure stress, and flow-rate conditions. Field treatment procedures are discussed, and several case histories are presented. All of the methods evaluated were effective in reducing proppant flowback under certain conditions. Heat-shrink film cutmore » into thin slivers proved to provide flowback reduction over broad temperature and closure stress ranges and was found to cause little impairment to fracture conductivity with some dependency on use concentration, temperature, and closure stress. The film materials were more resistant to damage caused by blending and pumping than all other materials evaluated. In addition, proppant packs, including consolidated packs, were significantly more tolerant of large, repeated stress changes. Field results indicate that the use of the heat-shrink film material as a flowback control agent permits more aggressive bean-up procedures following conventional fracturing treatments. Conventional dry-additive metering systems were used to add the film material to the fracturing fluid proppant slurry.« less
HMPT: Basic Radioactive Material Transportation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hypes, Philip A.
2016-02-29
Hazardous Materials and Packaging and Transportation (HMPT): Basic Radioactive Material Transportation Live (#30462, suggested one time) and Test (#30463, required initially and every 36 months) address the Department of Transportation’s (DOT’s) function-specific [required for hazardous material (HAZMAT) handlers, packagers, and shippers] training requirements of the HMPT Los Alamos National Laboratory (LANL) Labwide training. This course meets the requirements of 49 CFR 172, Subpart H, Section 172.704(a)(ii), Function-Specific Training.
Cordeiro, F; Baer, I; Robouch, P; Emteborg, H; Can, S Z; Krata, A; Zampella, M; Quétel, C R; Hearn, R; De la Calle, B
2013-01-01
The Institute for Reference Materials and Measurements (IRMM) of the Joint Research Centre (JRC), a Directorate-General of the European Commission, operates the International Measurement Evaluation Programme® (IMEP). It organises various types of inter-laboratory comparisons in support of European Union policies. This paper presents the results of a proficiency testing exercise (PT) focusing on the determination of total cadmium (Cd) and total lead (Pb) mass fractions in baby food in support to Commission Regulation (EC) 1881/2006 of 19 December 2006 setting maximum levels for certain contaminants in foodstuffs. The test material used in this exercise was soya-based baby food formula purchased in a local pharmacy and prepared by the Reference Materials Unit of the IRMM for this exercise. Sixty-six laboratories from 23 countries registered to the exercise and 61 of them reported results. Each participant received one bottle containing approximately 15 g of test material. Participants were asked to quantify the measurands in the powder and in the reconstituted formula. Reference values independent from the participants' results were established using isotope dilution inductively coupled plasma mass spectrometry. The total Cd mass fraction was determined by IRMM and LGC Ltd (UK), while the total Pb was determined by IRMM. The standard deviation for proficiency assessment σ^ was set at 22% of the assigned value for all measurands. Laboratories were rated with z- and ζ- (zeta) scores in accordance with ISO 13528. The outcome of this exercise is clearly influenced by the very low level of Cd and Pb content in the test material which triggered: a high number of 'less than' values; overestimated values especially for Pb very likely due to contamination; and a visible method influence in the case of Pb (methods based on atomic absorption were not sensitive enough to attain such low limits of detection). The results were also evaluated with regard to the reported limit of detection and some incoherencies were observed.
Performance testing of radiobioassay laboratories: In vivo measurements, Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacLellan, J.A.; Traub, R.J.; Olsen, P.C.
1990-04-01
A study of two rounds of in vivo laboratory performance testing was undertaken by Pacific Northwest Laboratory (PNL) to determine the appropriateness of the in vivo performance criteria of draft American National Standards Institute (ANSI) standard ANSI N13.3, Performance Criteria for Bioassay.'' The draft standard provides guidance to in vivo counting facilities regarding the sensitivity, precision, and accuracy of measurements for certain categories of commonly assayed radionuclides and critical regions of the body. This report concludes the testing program by presenting the results of the Round Two testing. Testing involved two types of measurements: chest counting for radionuclide detection inmore » the lung, and whole body counting for detection of uniformly distributed material. Each type of measurement was further divided into radionuclide categories as defined in the draft standard. The appropriateness of the draft standard criteria by measuring a laboratory's ability to attain them were judged by the results of both round One and Round Two testing. The testing determined that performance criteria are set at attainable levels, and the majority of in vivo monitoring facilities passed the criteria when complete results were submitted. 18 refs., 18 figs., 15 tabs.« less
Crack resistance determination of material by wedge splitting a chevron-notched specimen
NASA Astrophysics Data System (ADS)
Deryugin, Ye. Ye.
2017-12-01
An original method is proposed for the crack resistance determination of a material by wedge splitting of a chevron-notched specimen. It was developed at the Institute of Strength Physics and Materials Science SB RAS in the laboratory of Physical Mesomechanics and Nondestructive Methods of Control. An example of the crack resistance test of technical titanium VT1-0 is considered.
... Liver damage can lead to the buildup of ammonia and other toxic materials in the body. This ... Walking instability Laboratory tests may show a high ammonia level in the bloodstream and abnormal liver function. ...
(International seminar on the inelastic behavior of solids: Models and utilization)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruggles, M.B.
The traveler attended the International Seminar on the Inelastic Behavior of Solids: Models and Utilization, and presented an invited paper. Development and validation of constitutive models for complex loading and environmental conditions was the principal subject of the seminar. Session 1. Constitutive Models: Theoretical Development, Analysis and Comparison, and Session 2. Constitutive Models: Experimental Identification and Use, were of particular interest to the ORNL constitutive equations development effort. The traveler also visited the Applied Mechanics Laboratory at the University of Franche-Comte in Besancon and the Laboratory of Mechanics and Technology at the ENSET/Paris University 6 in Cachan. In both laboratoriesmore » the traveler held discussions regarding inelastic material behavior at room and elevated temperatures, exploratory testing and modeling, and materials testing equipment and techniques.« less
Shahbazian, M. D.; Valsamakis, A.; Boonyaratanakornkit, J.; Cook, L.; Pang, X. L.; Preiksaitis, J. K.; Schönbrunner, E. R.; Caliendo, A. M.
2013-01-01
Commutability of quantitative reference materials has proven important for reliable and accurate results in clinical chemistry. As international reference standards and commercially produced calibration material have become available to address the variability of viral load assays, the degree to which such materials are commutable and the effect of commutability on assay concordance have been questioned. To investigate this, 60 archived clinical plasma samples, which previously tested positive for cytomegalovirus (CMV), were retested by five different laboratories, each using a different quantitative CMV PCR assay. Results from each laboratory were calibrated both with lab-specific quantitative CMV standards (“lab standards”) and with common, commercially available standards (“CMV panel”). Pairwise analyses among laboratories were performed using mean results from each clinical sample, calibrated first with lab standards and then with the CMV panel. Commutability of the CMV panel was determined based on difference plots for each laboratory pair showing plotted values of standards that were within the 95% prediction intervals for the clinical specimens. Commutability was demonstrated for 6 of 10 laboratory pairs using the CMV panel. In half of these pairs, use of the CMV panel improved quantitative agreement compared to use of lab standards. Two of four laboratory pairs for which the CMV panel was noncommutable showed reduced quantitative agreement when that panel was used as a common calibrator. Commutability of calibration material varies across different quantitative PCR methods. Use of a common, commutable quantitative standard can improve agreement across different assays; use of a noncommutable calibrator can reduce agreement among laboratories. PMID:24025907
Development of indirect ring tension test for fracture characterization of asphalt mixtures
NASA Astrophysics Data System (ADS)
Zeinali Siavashani, Alireza
Low temperature cracking is a major distress in asphalt pavements. Several test configurations have been introduced to characterize the fracture properties of hot mix (HMA); however, most are considered to be research tools due to the complexity of the test methods or equipment. This dissertation describes the development of the indirect ring tension (IRT) fracture test for HMA, which was designed to be an effective and user-friendly test that could be deployed at the Department of Transportation level. The primary advantages of this innovative and yet practical test include: relatively large fracture surface test zone, simplicity of the specimen geometry, widespread availability of the required test equipment, and ability to test laboratory compacted specimens as well as field cores. Numerical modeling was utilized to calibrate the stress intensity factor formula of the IRT fracture test for various specimen dimensions. The results of this extensive analysis were encapsulated in a single equation. To develop the test procedure, a laboratory study was conducted to determine the optimal test parameters for HMA material. An experimental plan was then developed to evaluate the capability of the test in capturing the variations in the mix properties, asphalt pavement density, asphalt material aging, and test temperature. Five plant-produced HMA mixtures were used in this extensive study, and the results revealed that the IRT fracture test is highly repeatable, and capable of capturing the variations in the fracture properties of HMA. Furthermore, an analytical model was developed based on the viscoelastic properties of HMA to estimate the maximum allowable crack size for the pavements in the experimental study. This analysis indicated that the low-temperature cracking potential of the asphalt mixtures is highly sensitive to the fracture toughness and brittleness of the HMA material. Additionally, the IRT fracture test data seemed to correlate well with the data from the distress survey which was conducted on the pavements after five years of service. The maximum allowable crack size analysis revealed that a significant improvement could be realized in terms of the pavements performance if the HMA were to be compacted to a higher density. Finally, the IRT fracture test data were compared to the results of the disk-shaped compact [DC(t)] test. The results of the two tests showed a strong correlation; however, the IRT test seemed to be more repeatable. KEYWORDS: Asphalt Pavement, Low-Temperature Cracking, Fracture Mechanics, Material Characterization, Laboratory Testing.
2016-01-15
state-of-the-art equipment and to continue to produce excellent graduates in our field. Technical Approach In order to address our current testing ...New Additions • New material testing machine with environmental chamber • New dual-fuel test bed for Haeberle Laboratory • Upgrade existing...Southwark Emery universal test machine • 3D printer with ultra-high surface definition • CFD Workstations Since the inception of this grant, Webb
Fracture Toughness of Advanced Ceramics at Room Temperature
Quinn, George D.; Salem, Jonathan; Bar-on, Isa; Cho, Kyu; Foley, Michael; Fang, Ho
1992-01-01
This report presents the results obtained by the five U.S. participating laboratories in the Versailles Advanced Materials and Standards (VAMAS) round-robin for fracture toughness of advanced ceramics. Three test methods were used: indentation fracture, indentation strength, and single-edge pre-cracked beam. Two materials were tested: a gas-pressure sintered silicon nitride and a zirconia toughened alumina. Consistent results were obtained with the latter two test methods. Interpretation of fracture toughness in the zirconia alumina composite was complicated by R-curve and environmentally-assisted crack growth phenomena. PMID:28053447
Engine Propeller Research Building at the Lewis Flight Propulsion Laboratory
1955-02-21
The Engine Propeller Research Building, referred to as the Prop House, emits steam from its acoustic silencers at the National Advisory Committee for Aeronautics (NACA) Lewis Flight Propulsion Laboratory. In 1942 the Prop House became the first completed test facility at the new NACA laboratory in Cleveland, Ohio. It contained four test cells designed to study large reciprocating engines. After World War II, the facility was modified to study turbojet engines. Two of the test cells were divided into smaller test chambers, resulting in a total of six engine stands. During this period the NACA Lewis Materials and Thermodynamics Division used four of the test cells to investigate jet engines constructed with alloys and other high temperature materials. The researchers operated the engines at higher temperatures to study stress, fatigue, rupture, and thermal shock. The Compressor and Turbine Division utilized another test cell to study a NACA-designed compressor installed on a full-scale engine. This design sought to increase engine thrust by increasing its airflow capacity. The higher stage pressure ratio resulted in a reduction of the number of required compressor stages. The last test cell was used at the time by the Engine Research Division to study the effect of high inlet densities on a jet engine. Within a couple years of this photograph the Prop House was significantly altered again. By 1960 the facility was renamed the Electric Propulsion Research Building to better describe its new role in electric propulsion.
Performance of asphalt mixture incorporating recycled waste
NASA Astrophysics Data System (ADS)
Hamid, Nor Baizura; Abdullah, Mohd Ezree; Sanik, Mohd Erwan; Mokhtar, Mardiha; Kaamin, Masiri; Raduan, Rasyidah; Ramli, Mohd Zakwan
2017-12-01
Nowadays, the amount of premix waste was increased every year, especially at the batching plants. Normally, the waste materials will be discarded without doing any innovative and effective research about those materials. This situation has become one of the global concerns due to the increasing number of premix waste produced every year. Therefore, the aim of this study is to evaluate the performance of hot mix asphalt (HMA) using premix waste on improving asphalt mixture fatigue behaviour. The method used in this study was Superpave mix design method. The sample conducted in this study were 0%, 10%, 20%, 30%, and 100% of premix waste respectively. For a binder test, the laboratory test conducted were penetration test, softening test and thin film oven test while for the performance test were resilient modulus test and indirect tensile fatigue test. From the laboratory test, the resilient modulus test was conducted with two different temperature which was 25°C and 40°C. The result from that test was 20% of premix waste had higher resilient modulus at that two different temperatures compared to another samples. From that test also shown that the sample at the lower temperature which was 25°C has higher resilient modulus compared to the temperature of 40°C. Indirect tensile fatigue test showed that the 30% of premix waste sample was suitable for the modified asphalt mixture with referring to the maximum deformation and strain for comparison control, 10%,20%, and 100% of premix waste samples. So, it can be concluded that premix waste inhibits great potential as road construction material and suitable for repeated traffic loading.
USDA-ARS?s Scientific Manuscript database
Establishing standards for meat tenderness based on Warner-Bratzler shear force (WBSF) is complicated by the lack of methods for certifying WBSF testing among texture systems or laboratories. The objective of this study was to determine the suitability of using gelatin gels as a reference material ...
This protocol was developed under the Environmental Protection Agency's Environmental Technology Verification (ETV) Program, and is intended to be used as a guide in preparing laboratory test plans for the purpose of verifying the performance of grouting materials used for infra...
Structural materials from lunar simulants through thermal liquefaction
NASA Technical Reports Server (NTRS)
Desai, Chandra S.; Girdner, Kirsten
1992-01-01
Thermal liquefaction that allows development of intermediate ceramic composites from a lunar simulant with various admixtures is used to develop structural materials for construction on the moon. Bending and compressive properties of resulting composites are obtained from laboratory tests and evaluated with respect to the use of three different types and fibers.
Wear resistance of four types of vacuum-formed retainer materials: a laboratory study.
Raja, Taiyub A; Littlewood, Simon J; Munyombwe, Theresa; Bubb, Nigel L
2014-07-01
To investigate the resistance to wear of four different vacuum-formed retainer (VFR) materials: Essix C+, Essix ACE, Duran, and Tru-Tain. Essix C+ is a polypropylene polymer; the other materials are polyethylene co-polymers. The study was undertaken at the Leeds Dental Institute, Leeds, UK, with 26 samples in each group. The specimens were vacuum-formed according to the manufacturers' guidelines, and a custom-made wear-simulation machine was used to conduct the test. Each specimen was subjected to 1000 cycles of the wear simulation, with steatite balls as the antagonist material. The resistance to wear of the VFR materials was evaluated by measuring the maximum wear depth using noncontact, three-dimensional surface profilometry. The wear depth was given in micrometers. The median wear depth was 63.20 µm for the Essix C+ group, 7.88 µm for the Essix ACE group, 9.75 µm for the Duran group, and 12.08 µm for the Tru-Tain group. The Kruskal-Wallis test to compare the four VFR materials detected a statistically significant difference between the groups (P < .001). Comparisons of the groups using the Mann-Whitney U-test demonstrated that the Essix C+ group had significantly greater wear than the other three groups (P < .001). There was no statistically significant difference in median wear depth between the two groups with the least amount of wear-the Essix ACE and Duran groups. Under the standardized conditions of this laboratory study, the three polyethylene co-polymer materials-Essix ACE, Duran, and Tru-Tain-exhibited significantly less wear than the polypropylene material, Essix C+.
Results of Laboratory Tests of the Filtration Characteristics of Clay-Cement Concrete
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sol’skii, S. V., E-mail: solskiysv@vniig.ru; Lopatina, M. G., E-mail: LoptainaMG@vniig.ru; Legina, E. E.
Laboratory studies of the filtration characteristics of clay-cement concrete materials for constructing filtering diaphragms of earth dams by the method of secant piles are reported. Areas for further study aimed at improving the quality of construction, increasing operational safety, and developing a standards base for the design, construction, and operation of these systems are discussed.
Next-generation avionics packaging and cooling 'test results from a prototype system'
NASA Astrophysics Data System (ADS)
Seals, J. D.
The author reports on the design, material characteristics, and test results obtained under the US Air Force's advanced aircraft avionics packaging technologies (AAAPT) program, whose charter is to investigate new designs and technologies for reliable packaging, interconnection, and thermal management. Under this program, AT&T Bell Laboratories has completed the preliminary testing of and is evaluating a number of promising materials and technologies, including conformal encapsulation, liquid flow-through cooling, and a cyanate ester backplane. A fifty-two module system incorporating these and and other technologies has undergone preliminary cooling efficiency, shock, sine and random vibration, and maintenance testing. One of the primary objectives was to evaluate the interaction compatibility of new materials and designs with other components in the system.
DOT National Transportation Integrated Search
2008-09-01
The Resilient Modulus (Mr) of pavement materials and subgrades is an important input : parameter for the design of pavement structures. The Repeated Loading Triaxial (RLT) test : typically determines Mr. However, the RLT test requires well trained pe...
SAFETY AND SECURITY BUILDING, TRA614. ELEVATIONS. SECTIONS. TWO ROOF LEVELS. ...
SAFETY AND SECURITY BUILDING, TRA-614. ELEVATIONS. SECTIONS. TWO ROOF LEVELS. BLAW-KNOX 3150-814-2, 3/1950. INL INDEX NO. 531-0614-00-098-100703, REV. 6. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
SAFETY AND SECURITY BUILDING, TRA614. SIMPLIFIED FLOOR LAYOUT AND WEST ...
SAFETY AND SECURITY BUILDING, TRA-614. SIMPLIFIED FLOOR LAYOUT AND WEST ELEVATION. BLAW-KNOX 3150-14-1, 1/1950. INL INDEX NO. 531-0614-00-098-100024, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
PROCESS WATER BUILDING, TRA605. FLASH EVAPORATOR, CONDENSER (PROJECT FROM EVAPORATOR), ...
PROCESS WATER BUILDING, TRA-605. FLASH EVAPORATOR, CONDENSER (PROJECT FROM EVAPORATOR), AND STEAM EJECTOR (ALONG REAR WALL). INL NEGATIVE NO. 4377. M.H. Bartz, Photographer, 3/5/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Improving lab compaction specifications for flexible bases within the Texas DOT.
DOT National Transportation Integrated Search
2009-04-01
In Test Methods Tex-113-E and Tex-114-E, the Texas Department of Transportation (TxDOT) employs an impact hammer method of sample compaction for laboratory preparation of road base and subgrade materials for testing. In this third and final report do...
FAN HOUSE INTERIOR. THREE MOTOR DRIVES FOR POSITIVE DISPLACEMENT BLOWERS ...
FAN HOUSE INTERIOR. THREE MOTOR DRIVES FOR POSITIVE DISPLACEMENT BLOWERS LINE UP ON NORTH WALL. CONCRETE PEDESTALS. CAMERA FACES NORTHEAST. INL NEGATIVE NO. 4291. Unknown Photographer, 2/26/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
MTR BUILDING AND BALCONY FLOORS. CAMERA FACING EASTERLY. PHOTOGRAPHER DID ...
MTR BUILDING AND BALCONY FLOORS. CAMERA FACING EASTERLY. PHOTOGRAPHER DID NOT EXPLAIN DARK CLOUD. MTR WING WILL ATTACH TO GROUND FLOOR. INL NEGATIVE NO. 1567. Unknown Photographer, 2/28/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR BUILDING, TRA642, INTERIOR. BASEMENT. LIQUID SODIUM PIPING INSIDE CUBICLE ...
ETR BUILDING, TRA-642, INTERIOR. BASEMENT. LIQUID SODIUM PIPING INSIDE CUBICLE SHOWN IN ID-33-G-101. INL NEGATIVE NO. HD24-3-4. Mike Crane, Photographer, 11/2000 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
46 CFR 162.028-5 - Independent laboratories: Listing.
Code of Federal Regulations, 2014 CFR
2014-10-01
... MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Extinguishers, Fire, Portable, Marine Type... or tests of portable fire extinguishers: (a) For dry chemical, CO2, water and foam type portable fire...
46 CFR 162.028-5 - Independent laboratories: Listing.
Code of Federal Regulations, 2011 CFR
2011-10-01
... MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Extinguishers, Fire, Portable, Marine Type... or tests of portable fire extinguishers: (a) For dry chemical, CO2, water and foam type portable fire...
46 CFR 162.028-5 - Independent laboratories: Listing.
Code of Federal Regulations, 2013 CFR
2013-10-01
... MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Extinguishers, Fire, Portable, Marine Type... or tests of portable fire extinguishers: (a) For dry chemical, CO2, water and foam type portable fire...
46 CFR 162.028-5 - Independent laboratories: Listing.
Code of Federal Regulations, 2010 CFR
2010-10-01
... MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Extinguishers, Fire, Portable, Marine Type... or tests of portable fire extinguishers: (a) For dry chemical, CO2, water and foam type portable fire...
46 CFR 162.028-5 - Independent laboratories: Listing.
Code of Federal Regulations, 2012 CFR
2012-10-01
... MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Extinguishers, Fire, Portable, Marine Type... or tests of portable fire extinguishers: (a) For dry chemical, CO2, water and foam type portable fire...
Ambrose, Kate
2005-04-01
This is an online peer reviewed journal, whose board contains recognised experts in the wound management field and which i s edited by Stephen Thomas, author and director of the Surgical Materials Testing Laboratory.
MTR CAISSONS WERE DRILLED INTO BEDROCK. IN CENTER OF VIEW, ...
MTR CAISSONS WERE DRILLED INTO BEDROCK. IN CENTER OF VIEW, CONCRETE FLOWS FROM TRUCK INTO DRUM, WHICH IS LOWERED INTO CAISSON AND RELEASED AT BOTTOM OF HOLE. BEYOND, TRUCK-MOUNTED DRILLING RIG DRILLS HOLE FOR ANOTHER CAISSON NEAR EDGE OF EXCAVATION. MATERIAL REMOVED FROM HOLE IS CARRIED BY CONVEYOR TO WAITING TRUCK. INL NEGATIVE NO. 307. Unknown Photographer, 6/1950. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
HMPT: Hazardous Waste Transportation Live 27928, Test 27929
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simpson, Lewis Edward
2016-03-17
HMPT: Hazardous Waste Transportation (Live 27928, suggested one time and associated Test 27929, required initially and every 36 months) addresses the Department of Transportation (DOT) function-specific training requirements of the hazardous materials packagings and transportation (HMPT) Los Alamos National Laboratory (LANL) lab-wide training. This course addresses the requirements of the DOT that are unique to hazardous waste shipments. Appendix B provides the Title 40 Code of Federal Regulations (CFR) reference material needed for this course.
Fei, Yang; Zeng, Rong; Wang, Wei; He, Falin; Zhong, Kun
2015-01-01
Introduction To investigate the state of the art of intra-laboratory turnaround time (intra-TAT), provide suggestions and find out whether laboratories accredited by International Organization for Standardization (ISO) 15189 or College of American Pathologists (CAP) will show better performance on intra-TAT than non-accredited ones. Materials and methods 479 Chinese clinical laboratories participating in the external quality assessment programs of chemistry, blood gas, and haematology tests organized by the National Centre for Clinical Laboratories in China were included in our study. General information and the median of intra-TAT of routine and stat tests in last one week were asked in the questionnaires. Results The response rate of clinical biochemistry, blood gas, and haematology testing were 36% (479 / 1307), 38% (228 / 598), and 36% (449 / 1250), respectively. More than 50% of laboratories indicated that they had set up intra-TAT median goals and almost 60% of laboratories declared they had monitored intra-TAT generally for every analyte they performed. Among all analytes we investigated, the intra-TAT of haematology analytes was shorter than biochemistry while the intra-TAT of blood gas analytes was the shortest. There were significant differences between median intra-TAT on different days of the week for routine tests. However, there were no significant differences in median intra-TAT reported by accredited laboratories and non-accredited laboratories. Conclusions Many laboratories in China are aware of intra-TAT control and are making effort to reach the target. There is still space for improvement. Accredited laboratories have better status on intra-TAT monitoring and target setting than the non-accredited, but there are no significant differences in median intra-TAT reported by them. PMID:26110033
Aspects of bonding between resin luting cements and glass ceramic materials.
Tian, Tian; Tsoi, James Kit-Hon; Matinlinna, Jukka P; Burrow, Michael F
2014-07-01
The bonding interface of glass ceramics and resin luting cements plays an important role in the long-term durability of ceramic restorations. The purpose of this systematic review is to discuss the various factors involved with the bond between glass ceramics and resin luting cements. An electronic Pubmed, Medline and Embase search was conducted to obtain laboratory studies on resin-ceramic bonding published in English and Chinese between 1972 and 2012. Eighty-three articles were included in this review. Various factors that have a possible impact on the bond between glass ceramics and resin cements were discussed, including ceramic type, ceramic crystal structure, resin luting cements, light curing, surface treatments, and laboratory test methodology. Resin-ceramic bonding has been improved substantially in the past few years. Hydrofluoric acid (HF) etching followed by silanizaiton has become the most widely accepted surface treatment for glass ceramics. However, further studies need to be undertaken to improve surface preparations without HF because of its toxicity. Laboratory test methods are also required to better simulate the actual oral environment for more clinically compatible testing. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
NEET In-Pile Ultrasonic Sensor Enablement-Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
J. Daw; J. Rempe; J. Palmer
2014-09-01
Ultrasonic technologies offer the potential to measure a range of parameters during irradiation of fuels and materials, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes under harsh irradiation test conditions. There are two primary issues that currently limit in-pile deployment of ultrasonic sensors. The first is transducer survivability. The ability of ultrasonic transducer materials to maintain their useful properties during an irradiation must be demonstrated. The second issue is signal processing. Ultrasonic testing is typically performed in a lab or field environment, where the sensor and sample are accessible. The harsh nature ofmore » in-pile testing and the variety of desired measurements demand that an enhanced signal processing capability be developed to make in-pile ultrasonic sensors viable. To address these issues, the NEET ASI program funded a three year Ultrasonic Transducer Irradiation and Signal Processing Enhancements project, which is a collaborative effort between the Idaho National Laboratory, the Pacific Northwest National Laboratory, the Argonne National Laboratory, and the Pennsylvania State University. The objective of this report is to document the objectives and accomplishments from this three year project. As summarized within this document, significant work has been accomplished during this three year project.« less
Hoffman, Gerald L.
1996-01-01
A method for the chemical preparation of tissue samples that are subsequently analyzed for 22 trace metals is described. The tissue-preparation procedure was tested with three National Institute of Standards and Technology biological standard reference materials and two National Water Quality Laboratory homogenized biological materials. A low-temperature (85 degrees Celsius) nitric acid digestion followed by the careful addition of hydrogen peroxide (30-percent solution) is used to decompose the biological material. The solutions are evaporated to incipient dryness, reconstituted with 5 percent nitric acid, and filtered. After filtration the solutions were diluted to a known volume and analyzed by inductively coupled plasma-mass spectrometry (ICP-MS), inductively coupled plasma-atomic emission spectrometry (ICP-AES), and cold vapor-atomic absorption spectrophotometry (CV-AAS). Many of the metals were determined by both ICP-MS and ICP-AES. This report does not provide a detailed description of the instrumental procedures and conditions used with the three types of instrumentation for the quantitation of trace metals determined in this study. Statistical data regarding recovery, accuracy, and precision for individual trace metals determined in the biological material tested are summarized.
Neish, Emma M.; Miller, Nancy S.; Dhere, Tanvi; Burd, Eileen M.; Carpentieri, Cynthia; Sitchenko, Kaitlin L.
2017-01-01
ABSTRACT Fecal microbiota transplantation is an efficacious and inexpensive therapy for recurrent Clostridium difficile infection, yet its safety is thought to depend on appropriate fecal donor screening. FDA guidance for regulation of this procedure is in flux, but screening and manufacture of fecal material from asymptomatic donors present many challenges to clinical laboratories. This minireview summarizes FDA regulatory changes, principles of donor selection, and recommended laboratory screening practices for fecal microbiota transplantation. PMID:28077694
The NASA/JPL Evaluation of Oxygen Interactions with Materials-3 (EOIM-3)
NASA Technical Reports Server (NTRS)
Brinza, David E.; Chung, Shirley Y.; Minton, Timothy K.; Liang, Ranty H.
1994-01-01
The deleterious effects of hyperthermal atomic oxygen (AO) found in low-earth-orbit (LEO) environments on critical flight materials has been known since early shuttle flights. This corrosive effect is of considerable concern because it compromises the performance and longevity of spacecraft/satellite materials deployed for extended periods in LEO. The NASA Evaluation of Oxygen Interactions with Materials-3 (EOIM-3) experiment served as a testbed for a variety of candidate flight materials for space assets. A total of 57 JPL test specimens were present in six subexperiments aboard EOIM-3. In addition to a number of passive exposure materials for flight and advanced technology programs, several subexperiments were included to provide data for understanding the details of atomic oxygen interactions with materials. Data and interpretations are presented for the heated tray, heated strips, solar ultraviolet exposure, and scatterometer subexperiments, along with a detailed description of the exposure conditions experienced by materials in the various experiments. Mass spectra of products emerging from identical samples of a (sup 13)C-enriched polyimide polymer (chemically equivalent to Kapton) under atomic oxygen bombardment in space and in the laboratory were collected. Reaction products unambiguously detected in space were (sup 13)CO, NO, (sup 12)CO2, and (sup 13)CO2. These reaction products and two others, H2O and (sup 12)CO, were detected in the laboratory, along with inelastically scattered atomic and molecular oxygen. Qualitative agreement was seen in the mass spectra taken in space and in the laboratory; the agreement may be improved by reducing the fraction of O2 in the laboratory molecular beam.
RECENT ADVANCES IN HIGH TEMPERATURE ELECTROLYSIS AT IDAHO NATIONAL LABORATORY: SINGLE CELL TESTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
X. Zhang; J. E. O'Brien; R. C. O'Brien
2012-07-01
An experimental investigation on the performance and durability of single solid oxide electrolysis cells (SOECs) is under way at the Idaho National Laboratory. In order to understand and mitigate the degradation issues in high temperature electrolysis, single SOECs with different configurations from several manufacturers have been evaluated for initial performance and long-term durability. A new test apparatus has been developed for single cell and small stack tests from different vendors. Single cells from Ceramatec Inc. show improved durability compared to our previous stack tests. Single cells from Materials and Systems Research Inc. (MSRI) demonstrate low degradation both in fuel cellmore » and electrolysis modes. Single cells from Saint Gobain Advanced Materials (St. Gobain) show stable performance in fuel cell mode, but rapid degradation in the electrolysis mode. Electrolyte-electrode delamination is found to have significant impact on degradation in some cases. Enhanced bonding between electrolyte and electrode and modification of the microstructure help to mitigate degradation. Polarization scans and AC impedance measurements are performed during the tests to characterize the cell performance and degradation.« less
Design and Testing of Braided Composite Fan Case Materials and Components
NASA Technical Reports Server (NTRS)
Roberts, Gary D.; Pereira, J. Michael; Braley, Michael S.; Arnold, William a.; Dorer, James D.; Watson, William R/.
2009-01-01
Triaxial braid composite materials are beginning to be used in fan cases for commercial gas turbine engines. The primary benefit for the use of composite materials is reduced weight and the associated reduction in fuel consumption. However, there are also cost benefits in some applications. This paper presents a description of the braided composite materials and discusses aspects of the braiding process that can be utilized for efficient fabrication of composite cases. The paper also presents an approach that was developed for evaluating the braided composite materials and composite fan cases in a ballistic impact laboratory. Impact of composite panels with a soft projectile is used for materials evaluation. Impact of composite fan cases with fan blades or blade-like projectiles is used to evaluate containment capability. A post-impact structural load test is used to evaluate the capability of the impacted fan case to survive dynamic loads during engine spool down. Validation of these new test methods is demonstrated by comparison with results of engine blade-out tests.
Rapid Quench in an Electrostatic Levitator
NASA Technical Reports Server (NTRS)
SanSoucie, Michael P.; Rogers, Jan R.; Matson, Douglas M.
2016-01-01
The Electrostatic Levitation (ESL) Laboratory at the NASA Marshall Space Flight Center (MSFC) is a unique facility for investigators studying high-temperature materials. The ESL laboratory's main chamber has been upgraded with the addition of a rapid quench system. This system allows samples to be dropped into a quench vessel that can be filled with a low melting point material, such as a gallium or indium alloy, as a quench medium. Thereby allowing rapid quenching of undercooled liquid metals. Up to eight quench vessels can be loaded into a wheel inside the chamber that is indexed with control software. The system has been tested successfully with samples of zirconium, iron-cobalt alloys, titanium-zirconium-nickel alloys, and a silicon-cobalt alloy. This new rapid quench system will allow materials science studies of undercooled materials and new materials development. In this presentation, the system is described and some initial results are presented.
Submersion Quenching of Undercooled Liquid Metals in an Electrostatic Levitator
NASA Technical Reports Server (NTRS)
SanSoucie, Michael P.; Rogers, Jan R.
2016-01-01
The NASA Marshall Space Flight Center (MSFC) electrostatic levitation (ESL) laboratory has a long history of providing materials research and thermophysical property data. The laboratory has recently added a new capability, a rapid quench system. This system allows samples to be dropped into a quench vessel that can be filled with a low melting point material, such as a gallium or indium alloy. Thereby allowing rapid quenching of undercooled liquid metals and alloys. This is the first submersion quench system inside an electrostatic levitator. The system has been tested successfully with samples of zirconium, iron-cobalt alloys, titanium-zirconium-nickel alloys, and silicon-cobalt alloys. This rapid quench system will allow materials science studies of undercooled materials and new materials development, including studies of metastable phases and transient microstructures. In this presentation, the system is described and some initial results are presented.
Portable vibro-acoustic testing system for in situ microstructure characterization and metrology
NASA Astrophysics Data System (ADS)
Smith, James A.; Nichol, Corrie I.; Zuck, Larry D.; Fatemi, Mostafa
2018-04-01
There is a need in research reactors like the one at INL to inspect irradiated materials and structures. The goal of this work is to develop a portable scanning infrastructure for a material characterization technique called vibro-acoustography (VA) that has been developed by the Idaho National laboratory for nuclear applications to characterize fuel, cladding materials, and structures. The proposed VA technology is based on ultrasound and acoustic waves; however, it provides information beyond what is available from the traditional ultrasound techniques and can expand the knowledge on nuclear material characterization and microstructure evolution. This paper will report on the development of a portable scanning system that will be set up to characterize materials and components in open water reactors and canals in situ. We will show some initial laboratory results of images generated by vibro-acoustics of surrogate fuel plates and graphite structures and discuss the design of the portable system.
NASA Technical Reports Server (NTRS)
Diaz, J. O.
1985-01-01
Composites consisting of tungsten alloy wires in superalloy matrices are being studied because they offer the potential for increased strength compared to current materials used at temperatures up to at least 1093 C (2000F). Previous research at the NASA Lewis Research Center and at other laboratories in the U.S., Europe, and Japan has demonstrated laboratory feasibility for fiber reinforced superalloys (FRS). The data for the mechanical and physical properties used to evaluate candidate materials is limited and a need exists for a more detailed and complete data base. The focus of this work is to develop a test procedure to provide a more complete FRS data base to quantitatively evaluate the composite's potential for component applications. This paper will describe and discuss the equipment and procedures under development to obtain elevated temperature tensile stress-strain, strength and modulus data for the first generation of tungsten fiber reinforced superalloy composite (TFRS) materials. Tensile stress-strain tests are conducted using a constant crosshead speed tensile testing machine and a modified load-strain measuring apparatus. Elevated temperature tensile tests are performed using a resistance wound commercial furnace capable of heating test specimens up to 1093 C (2000 F). Tensile stress-strain data are obtained for hollow tubular stainless steel specimens serving as a prototype for future composite specimens.
A laboratory comparison of individual Targis/Vectris posts with standard fiberglass posts.
Corsalini, Massimo; Genovese, Katia; Lamberti, Luciano; Pappalettere, Carmine; Carella, Mauro; Carossa, Stefano
2007-01-01
This article presents an in vitro analysis of a specific occlusal loading test on endodontically treated teeth restored with 2 different composite post materials. Individual, customized posts (IFPs) were compared to standard fiberglass posts (SFPs). The selected IFPs (standard cylindric Targis/Vectris posts) were compared to SFPs (Conic 6% Post, Ghimas). The posts were first subjected to a 3-point bending test to compare their flexural elastic properties. They were then used to restore 22 endodontically treated artificial maxillary central incisors and subjected to a specific occlusal loading simulation test. The loading test showed that IFP restorations performed better than SFP restorations. A clinical evaluation of this laboratory observation is suggested.
HSRP and HSRP Partner Analytical Methods and Protocols
HSRP has worked with various partners to develop and test analytical methods and protocols for use by laboratories charged with analyzing environmental and/or buildling material samples following contamination incident.
DOT National Transportation Integrated Search
2002-07-25
The Bituminous Mixtures Laboratory (BML) specializes in the research of asphalt pavement mixtures. This lab supports FHWA's efforts to develop, evaluate and improve materials, mixture design technology and performance-based tests for asphalt paving m...
NASA Technical Reports Server (NTRS)
1983-01-01
A series of studies in which films and liquid spray-on materials were evaluated in the laboratory for transport aircraft external surface coatings are summarized. Elastomeric polyurethanes were found to best meet requirements. Two commercially available products, CAAPCO B-274 and Chemglaze M313, were subjected to further laboratory testing, airline service evaluations, and drag-measurement flight tests. It was found that these coatings were compatible with the severe operating environment of airlines and that coatings reduced airplane drag. An economic analysis indicated significant dollar benefits to airlines from application of the coatings.
Vlieg-Boerstra, Berber J; Bijleveld, Charles M A; van der Heide, Sicco; Beusekamp, Berta J; Wolt-Plompen, Saskia A A; Kukler, Jeanet; Brinkman, Joep; Duiverman, Eric J; Dubois, Anthony E J
2004-02-01
The use of double-blind, placebo-controlled food challenges (DBPCFCs) is considered the gold standard for the diagnosis of food allergy. Despite this, materials and methods used in DBPCFCs have not been standardized. The purpose of this study was to develop and validate recipes for use in DBPCFCs in children by using allergenic foods, preferably in their usual edible form. Recipes containing milk, soy, cooked egg, raw whole egg, peanut, hazelnut, and wheat were developed. For each food, placebo and active test food recipes were developed that met the requirements of acceptable taste, allowance of a challenge dose high enough to elicit reactions in an acceptable volume, optimal matrix ingredients, and good matching of sensory properties of placebo and active test food recipes. Validation was conducted on the basis of sensory tests for difference by using the triangle test and the paired comparison test. Recipes were first tested by volunteers from the hospital staff and subsequently by a professional panel of food tasters in a food laboratory designed for sensory testing. Recipes were considered to be validated if no statistically significant differences were found. Twenty-seven recipes were developed and found to be valid by the volunteer panel. Of these 27 recipes, 17 could be validated by the professional panel. Sensory testing with appropriate statistical analysis allows for objective validation of challenge materials. We recommend the use of professional tasters in the setting of a food laboratory for best results.
A document review to characterize Atomic International SNAP fuels shipped to INEL 1966--1973
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wahnschaffe, S.D.; Lords, R.E.; Kneff, D.W.
1995-09-01
This report provides the results of a document search and review study to obtain information on the spent fuels for the following six Nuclear Auxiliary Power (SNAP) reactor cores now stored at the Idaho National Engineering Laboratory (INEL): SNAP-2 Experimental Reactor, SNAP-2 Development Reactor, SNAP-10A Ground Test Reactor, SNAP-8 Experimental Reactor, SNAP-8 Development Reactor, and Shield Test Reactor. The report also covers documentation on SNAP fuel materials from four in-pile materials tests: NAA-82-1, NAA-115-2, NAA-117-1, and NAA-121. Pieces of these fuel materials are also stored at INEL as part of the SNAP fuel shipments.
NASA Technical Reports Server (NTRS)
Hirschberg, M. H.
1978-01-01
Twenty laboratories in six countries participated in this program, each testing its own materials of interest under its own laboratory conditions. In this way the results obtained provided validation of the Strainrange Partitioning (SRP) method for a wide range of materials and insured maximum usefulness to each of the participating laboratories. The first, very necessary step in the evaluation of any life prediction approach - assessing the ability of the method to predict life of simple laboratory specimens subjected to complex loading, was thereby taken. The culmination of this program was the Specialists Meeting that was held in Aalborg, Denmark in April of 1978. At that meeting the various investigators shared their findings, thus providing the basis for an in-depth evaluation of the SRP method. While the results were variable from laboratory to laboratory, most investigators agreed that the SRP method was a significant step toward life prediction in the presence of high temperature and cyclic stresses.
Biomagnetic Pair Therapy and Typhoid Fever: A Pilot Study.
Frank, Bryan L
2017-10-01
Objective: This pilot study examined the laboratory responses of patients with laboratory-documented typhoid fever who were treated with Biomagnetic Pair Therapy (BPT; medical biomagnetism), a specific application of pairs of magnets for various ailments that are infectious and otherwise. Materials and Methods: This study was an assessment of patients' response to treatment with only BPT for Salmonella typhi infections (typhoid fever) using standard conventional laboratory techniques. The research was conducted in an outpatient village clinic in Kenya. There were 52 participants who were evaluated for possible systemic illness, including typhoid fever, from an open-label study. Participants who felt sick and requested testing for possible typhoid fever were tested with a standard Widal test by a certified laboratory technician. Participants who tested positive (13 patients) were then treated with BPT (a "First Aid" approach) only. These participants then returned for follow-up laboratory and clinical evaluations after 2 days. Results: Most of the participants (10 of 13) retested as negative, and all patients reported symptomatic clinical improvement. Conclusions: As a significant majority of participants demonstrated clearing of their S. typhi after BPT, this technique should be studied further in larger trials for its efficacy in treating typhoid fever.
ETR ELECTRICAL BUILDING, TRA648. EMERGENCY STANDBY GENERATOR AND DIESEL UNIT. ...
ETR ELECTRICAL BUILDING, TRA-648. EMERGENCY STANDBY GENERATOR AND DIESEL UNIT. METAL ROOF AND PUMICE BLOCK WALLS. CAMERA FACING SOUTHWEST. INL NEGATIVE NO. 56-3708. R.G. Larsen, Photographer, 11/13/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR ELECTRICAL BUILDING, TRA648. FLOOR PLANS FOR FIRST FLOOR AND ...
ETR ELECTRICAL BUILDING, TRA-648. FLOOR PLANS FOR FIRST FLOOR AND BASEMENT. SECTIONS. KAISER ETR-5528-MTR-648-A-2, 12/1955. INL INDEX NO. 532-0648-00-486-101402, REV. 6. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR BUILDING, TRA642, INTERIOR. CONSOLE FLOOR, SOUTH HALF. CABLE TUNNEL. ...
ETR BUILDING, TRA-642, INTERIOR. CONSOLE FLOOR, SOUTH HALF. CABLE TUNNEL. CAMERA FACING SOUTH INTO ETR ELECTRICAL BUILDING (TRA-648). INL NEGATIVE NO. HD46-20-2. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR ELECTRICAL BUILDING, TRA648. ELEVATIONS AND DETAILS. ROOF PLAN. DOOR ...
ETR ELECTRICAL BUILDING, TRA-648. ELEVATIONS AND DETAILS. ROOF PLAN. DOOR SCHEDULE. KAISER ETR-5528-MTR-648-A-3, 1/1956. INL INDEX NO. 532-0648-00-486-101403, REV. 5. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR BUILDING, TRA642, INTERIOR. BASEMENT. ROLLUP DOOR TO CUBICLE POSTS ...
ETR BUILDING, TRA-642, INTERIOR. BASEMENT. ROLLUP DOOR TO CUBICLE POSTS CAUTION SIGNS BECAUSE OF SODIUM HAZARD WITHIN. INL NEGATIVE NO. HD24-3-1. Mike Crane, Photographer, 11/2000 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
USDA-ARS?s Scientific Manuscript database
Filter treatment may be a viable means for removing the nitrate, phosphate, and pesticides discharged with agricultural drainage waters that cause adverse environmental impacts within the U.S. on local, regional, and national scales. Laboratory batch test screening for agricultural drainage water ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1990-02-01
This volume contains appendices D6 through D8 containing laboratory test data: from MK-F investigation, 1987, Old Rifle and New Rifle sites; on bentonite amended radon barrier material; and from MK-F investigation, 1987, riprap tests.
MTR WING, TRA604, INTERIOR. BASEMENT. WEST CORRIDOR. CAMERA FACES NORTH. ...
MTR WING, TRA-604, INTERIOR. BASEMENT. WEST CORRIDOR. CAMERA FACES NORTH. HVAC AREA IS AT RIGHT OF CORRIDOR. INL NEGATIVE NO. HD46-13-3. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR HEAT EXCHANGER BUILDING, TRA644. DETAIL OF SOUTH SIDE BUILDING ...
ETR HEAT EXCHANGER BUILDING, TRA-644. DETAIL OF SOUTH SIDE BUILDING INSET. DEMINERALIZER WING AT RIGHT. CAMERA FACING NORTH. INL NEGATIVE NO. HD46-36-2. Mike Crane, Photographer, 4/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Philosophic Heuristic Instruction (PHI)--II.
ERIC Educational Resources Information Center
Coole, Walter A.
This publication contains a course outline and syllabus, self-study units, and testing materials finished and tested in the Open Classroom, an auto-tutorial learning laboratory at Skagit Valley College (Washington). This self-contained course in informal logic is organized around problem-solving strategy and a collection of modules for extensive…
MTR STACK, TRA710, CONTEXTUAL VIEW, CAMERA FACING SOUTH. PERIMETER SECURITY ...
MTR STACK, TRA-710, CONTEXTUAL VIEW, CAMERA FACING SOUTH. PERIMETER SECURITY FENCE AND SECURITY LIGHTING IN VIEW AT LEFT. INL NEGATIVE NO. HD52-1-1. Mike Crane, Photographer, 5/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
REACTIVITY MEASUREMENT FACILITY, UNDER CONSTRUCTION OVER MTR CANAL IN BASEMENT ...
REACTIVITY MEASUREMENT FACILITY, UNDER CONSTRUCTION OVER MTR CANAL IN BASEMENT OF MTR BUILDING, TRA-603. WOOD PLANKS REST ON CANAL WALL OBSERVABLE IN FOREGROUND. INL NEGATIVE NO. 11745. Unknown Photographer, 8/20/1954 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
DOT National Transportation Integrated Search
2009-10-01
This report documents the results of a study that was conducted to characterize the behavior of geogrid reinforced base : course materials. The research was conducted through an experimental testing and numerical modeling programs. The : experimental...
MTR WING, TRA604. PRECAST CONCRETE PANELS AND DIMENSIONS FOR PANELS ...
MTR WING, TRA-604. PRECAST CONCRETE PANELS AND DIMENSIONS FOR PANELS K THROUGH Q. BLAW-KNOX 3150-804-21, SHEET #2, 11/1950. INL INDEX NO. 531-0604-62-098-100645, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
NORTH BASEMENT WALL. IBEAM COLUMNS HAVE BEEN ENCASED IN CONCRETE. ...
NORTH BASEMENT WALL. I-BEAM COLUMNS HAVE BEEN ENCASED IN CONCRETE. STEEL BEAMS LAY ACROSS FIRST FLOOR AWAITING CONCRETE POUR. CAMERA LOOKS SOUTHWEST. INL NEGATIVE NO. 735. Unknown Photographer, 10/6/1950 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
42 CFR 84.308 - Additional testing.
Code of Federal Regulations, 2013 CFR
2013-10-01
... §§ 84.304 through 84.307. These units will be evaluated for fire and explosion hazards using the tests....S.C. 552(a) and 1 CFR Part 51. All approved material is available for inspection at NIOSH, National Personal Protection Technology Laboratory (NPPTL), Bruceton Research Center, 626 Cochrans Mill Road...
42 CFR 84.308 - Additional testing.
Code of Federal Regulations, 2014 CFR
2014-10-01
... §§ 84.304 through 84.307. These units will be evaluated for fire and explosion hazards using the tests....S.C. 552(a) and 1 CFR Part 51. All approved material is available for inspection at NIOSH, National Personal Protection Technology Laboratory (NPPTL), Bruceton Research Center, 626 Cochrans Mill Road...
42 CFR 84.308 - Additional testing.
Code of Federal Regulations, 2012 CFR
2012-10-01
... §§ 84.304 through 84.307. These units will be evaluated for fire and explosion hazards using the tests....S.C. 552(a) and 1 CFR Part 51. All approved material is available for inspection at NIOSH, National Personal Protection Technology Laboratory (NPPTL), Bruceton Research Center, 626 Cochrans Mill Road...
PROCESS WATER BUILDING, TRA605. ONE OF THREE EVAPORATORS BEFORE IT ...
PROCESS WATER BUILDING, TRA-605. ONE OF THREE EVAPORATORS BEFORE IT IS INSTALLED IN UPPER LEVEL OF EAST HALF OF BUILDING. INL NEGATIVE NO. 1533. Unknown Photographer, 3/1/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ADVANCED REACTIVITY MEASUREMENT FACILITY, TRA660, INTERIOR. REACTOR INSIDE TANK. METAL ...
ADVANCED REACTIVITY MEASUREMENT FACILITY, TRA-660, INTERIOR. REACTOR INSIDE TANK. METAL WORK PLATFORM ABOVE. THE REACTOR WAS IN A SMALL WATER-FILLED POOL. INL NEGATIVE NO. 66-6373. Unknown Photographer, ca. 1966 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR, TRA642. BENCH MARK AND ELEVATION LOCATIONS, FLOOR LOADING DATA, ...
ETR, TRA-642. BENCH MARK AND ELEVATION LOCATIONS, FLOOR LOADING DATA, CRANE WORKING AREAS. PHILLIPS PETROLEUM COMPANY ETR-D-1584, 5/1959. INL INDEX NO. 532-0642-00-706-020323, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
The role of light microscopy in aerospace analytical laboratories
NASA Technical Reports Server (NTRS)
Crutcher, E. R.
1977-01-01
Light microscopy has greatly reduced analytical flow time and added new dimensions to laboratory capability. Aerospace analytical laboratories are often confronted with problems involving contamination, wear, or material inhomogeneity. The detection of potential problems and the solution of those that develop necessitate the most sensitive and selective applications of sophisticated analytical techniques and instrumentation. This inevitably involves light microscopy. The microscope can characterize and often identify the cause of a problem in 5-15 minutes with confirmatory tests generally less than one hour. Light microscopy has and will make a very significant contribution to the analytical capabilities of aerospace laboratories.
Land, Sally; Cunningham, Philip; Zhou, Jialun; Frost, Kevin; Katzenstein, David; Kantor, Rami; Chen, Yi-Ming Arthur; Oka, Shinichi; DeLong, Allison; Sayer, David; Smith, Jeffery; Dax, Elizabeth M.; Law, Matthew
2010-01-01
The TREAT Asia (Therapeutics, Research, Education, and AIDS Training in Asia) Network is building capacity for Human Immunodeficiency Virus Type-1 (HIV-1) drug resistance testing in the region. The objective of the TREAT Asia Quality Assessment Scheme – designated TAQAS – is to standardize HIV-1 genotypic resistance testing (HIV genotyping) among laboratories to permit rigorous comparison of results from different clinics and testing centres. TAQAS has evaluated three panels of HIV-1-positive plasma from clinical material or low-passage, culture supernatant for up to 10 Asian laboratories. Laboratory participants used their standard protocols to perform HIV genotyping. Assessment was in comparison to a target genotype derived from all participants and the reference laboratory’s result. Agreement between most participants at the edited nucleotide sequence level was high (>98%). Most participants performed to the reference laboratory standard in detection of drug resistance mutations (DRMs). However, there was variation in the detection of nucleotide mixtures (0–83%) and a significant correlation with the detection of DRMs (p < 0.01). Interpretation of antiretroviral resistance showed ~70% agreement among participants when different interpretation systems were used but >90% agreement with a common interpretation system, within the Stanford University Drug Resistance Database. Using the principles of external quality assessment and a reference laboratory, TAQAS has demonstrated high quality HIV genotyping results from Asian laboratories. PMID:19490972