Sample records for maxillary complete denture

  1. A comparative analysis of salivary factors and maxillary denture retention in different arch forms: An in vivo study.

    PubMed

    Shekhar, Abhishek; Das, Samiran; Bhattacharyya, Jayanta; Goel, Preeti; Majumdar, Sayan; Ghosh, Soumitra

    2018-01-01

    This study aims to find the effect of change in different salivary factors before and after complete denture insertion and to measure the maxillary denture retention in different arch forms. Thirty completely edentulous individuals (10 each of square, tapered, and ovoid arch form of maxilla) belonging to the age group of 40-70 years were selected. Salivary factors (flow, density, pH, viscosity, and total protein) were evaluated before and after denture insertion. Retention of maxillary denture was measured in all the different arch forms. Student's independent sample's t -test was applied. The correlation was analyzed by Pearson's correlation analysis. While mean flow rate and pH of saliva increased, mean viscosity, total protein, and density of saliva decreased after maxillary complete denture insertion. A positive correlation was found between retention and total maxillary basal surface area. Retention value was found to be greatest in square type and least in tapered type. Complete denture acts as a mechanical stimulant thus increasing flow rate and pH immediately after complete denture insertion. Density, total protein, and viscosity of saliva decreased after complete denture insertion which may be due to increase in water content of saliva. The retention of maxillary complete denture does not seem to depend on the rate of change of the salivary factors, before and after complete denture insertion. Total basal surface area and maxillary denture retention values were highest in square arch form and least in tapered arch form.

  2. Effect of location of glass fiber-reinforced composite reinforcement on the flexural properties of a maxillary complete denture in vitro.

    PubMed

    Takahashi, Yutaka; Yoshida, Kaneyoshi; Shimizu, Hiroshi

    2011-07-01

    Objective. To evaluate the effect of the location of glass fiber-reinforced composite (FRC) reinforcement on the flexural load at the proportional limit (FL-PL) and the flexural deflection of a maxillary acrylic resin complete denture. Material and methods. Maxillary acrylic resin complete dentures strengthened with and without FRC reinforcement were tested. The polymerized FRC was embedded in the denture base resin in the doughy state and placed (1) under the ridge lap region, (2) in the anterior region, (3) in the middle region or (4) in the anterior and posterior regions. The FL-PL and flexural deflection value at the 100-N loading point of the reinforced maxillary denture specimens were tested. Results. All of the reinforced dentures had a higher FL-PL than the denture without reinforcement but the FL-PL values of all the dentures were not significantly different from each other. The efficiency of the FRC reinforcement compared to the unreinforced denture was 1.54-1.75 times greater. All of the reinforced dentures showed significantly lower deflection compared to the unreinforced denture, but the flexural deflections of all the dentures were not significantly different from each other. Conclusions. The location of the FRC reinforcement did not affect the fracture resistance of the maxillary acrylic resin complete denture. All of the reinforced dentures had higher FL-PL and lower flexural deflection than the denture without reinforcement.

  3. Maxillary complete denture outcome with two-implant supported mandibular overdentures. A systematic review.

    PubMed

    Rutkunas, Vygandas; Mizutani, Hiroshi; Peciuliene, Vytaute; Bendinskaite, Ruta; Linkevicius, Tomas

    2008-01-01

    Research data regarding maxillary complete denture outcome with two-implant supported mandibular overdentures are not consistent. Considering multiple publications on implant supported mandibular overdentures, it was decided to summarize currently present evidence on the maxillary complete dentures opposed by implant-supported mandibular overdentures, and analyze factors that could potentially influence the outcomes. The articles from 1985 to 2007 related to the topic were identified in the online MEDLINE/Pubmed and other databases and manually. Primary articles were scanned, and irrelevant studies were excluded from the further review process. Potentially relevant titles and abstracts were provisionally included for consideration on the basis of full text articles. Full text articles were obtained from on-line and printed sources. The data from the studies were extracted and reviewed. The study has failed to identify any prospective satisfying inclusion/exclusion criteria RCT reporting on maxillary bone resorption. The number of maxillary complete denture relining incidences per patient was constantly increasing during the 10-year period. Maxillary complete denture remake incidences comprised 16-33 % of the number of patients followed during the 10-year period. Comparing patient satisfaction with upper dentures at the baseline and after two years, no decrease in satisfaction was noticed. There is no evidence that maxillary ridge resorption is accelerated with certain types of two-implant supported mandibular overdenture attachments. Most common complication for the maxilla - prosthetic maintenance. There is a risk of decreased patient satisfaction with bar-supported mandibular overdenture. Further studies are needed to provide evidence for the maxillary complete denture outcome with two-implant supported mandibular overdentures.

  4. On the clinical deformation of maxillary complete dentures. Influence of denture-base design and shape of denture-bearing tissue.

    PubMed

    el Ghazali, S; Glantz, P O; Strandman, E; Randow, K

    1989-04-01

    This paper aimed to study the influence of denture base design and the shape of the denture-supporting area on the functional deformation of maxillary complete dentures. Six strain-gauged duplicate maxillary dentures were made for the study of two test subjects with different shapes of the palatal vault. Each subject was supplied with two polymethyl methacrylate dentures, one with a 1-mm-thick palatal base and the other 2 mm thick. A third denture was constructed with a cobalt-chromium base. The functional loading tests included maximum biting and the chewing of the food test samples. An analysis based on chewing time and total number of chewing cycles per test piece was also made. The results showed that surface straining is highly complex at the anterior part of the maxillary dentures constructed from polymethyl methacrylate and that increasing the denture thickness per se might not be accompanied by a reduction of strain. The results also suggest that high thrust to the supporting tissue is produced with high palatal vault dentures made in polymethyl methacrylate. The study proposes that cobalt-chromium bases may be used in maxillary dentures to reduce functional deformation and thrust to the supporting tissues at the anterior part of the maxilla.

  5. Speech intelligibility enhancement after maxillary denture treatment and its impact on quality of life.

    PubMed

    Knipfer, Christian; Riemann, Max; Bocklet, Tobias; Noeth, Elmar; Schuster, Maria; Sokol, Biljana; Eitner, Stephan; Nkenke, Emeka; Stelzle, Florian

    2014-01-01

    Tooth loss and its prosthetic rehabilitation significantly affect speech intelligibility. However, little is known about the influence of speech deficiencies on oral health-related quality of life (OHRQoL). The aim of this study was to investigate whether speech intelligibility enhancement through prosthetic rehabilitation significantly influences OHRQoL in patients wearing complete maxillary dentures. Speech intelligibility by means of an automatic speech recognition system (ASR) was prospectively evaluated and compared with subjectively assessed Oral Health Impact Profile (OHIP) scores. Speech was recorded in 28 edentulous patients 1 week prior to the fabrication of new complete maxillary dentures and 6 months thereafter. Speech intelligibility was computed based on the word accuracy (WA) by means of an ASR and compared with a matched control group. One week before and 6 months after rehabilitation, patients assessed themselves for OHRQoL. Speech intelligibility improved significantly after 6 months. Subjects reported a significantly higher OHRQoL after maxillary rehabilitation with complete dentures. No significant correlation was found between the OHIP sum score or its subscales to the WA. Speech intelligibility enhancement achieved through the fabrication of new complete maxillary dentures might not be in the forefront of the patients' perception of their quality of life. For the improvement of OHRQoL in patients wearing complete maxillary dentures, food intake and mastication as well as freedom from pain play a more prominent role.

  6. Efficacy of bone substitute material in preserving volume when placing a maxillary immediate complete denture: study protocol for the PANORAMIX randomized controlled trial.

    PubMed

    Rignon-Bret, Christophe; Hadida, Alain; Aidan, Alexis; Nguyen, Thien-Huong; Pasquet, Gerard; Fron-Chabouis, Helene; Wulfman, Claudine

    2016-05-20

    Bone preservation is an essential issue in the context of last teeth extraction and complete edentulism. The intended treatment, whether a complete denture or an implant placement, is facilitated with a voluminous residual ridge. Bone resorption after multiple extractions has not been as well studied as the bone resorption that occurs after the extraction of a single tooth. Recent advances in bone substitute materials have revived this issue. The purpose of this study is to evaluate the interest in using bone substitute material to fill the socket after last teeth extraction in a maxillary immediate complete denture procedure compared with the conventional protocol without socket filling. A randomized, controlled, clinical trial was designed. The 34 participants eligible for maxillary immediate complete denture were divided into two groups. Complete dentures were prepared despite persistence of the last anterior teeth. The control group received a conventional treatment including denture placement immediately after extractions. In the experimental group, in addition to the immediate denture placement, a xenograft bone-substitute material (Bio-Oss Collagen®) was placed in the fresh sockets. The primary outcome of the study is to compare mean bone ridge height loss 1 year after maxillary immediate complete denture placement, with or without bone-substitute material, in incisor and canine sockets. The secondary outcomes are to compare the average bone ridge height and width loss for each extraction site. An original quantitative evaluation method using cone beam computed tomography was designed for reproducible measurements, with a radio-opaque denture duplicate. Two independent operators perform the radiologic measurements. The immediate complete denture technique limits bone resorption in multiple extraction situations and thus allows better denture retention and better options for implant placement. To compare the benefit of using any bone socket-filling material, we proposed a quantitative evaluation protocol of resorption in the specific case of the last anterior maxillary teeth extraction with immediate denture placement. ClinicalTrials.gov, NCT02120053 . Registered on 18 April 2014.

  7. A clinical evaluation denture adhesives used by patients with xerostomia.

    PubMed

    Bogucki, Zdzislaw A; Napadlek, Piotr; Dabrowa, Tomasz

    2015-02-01

    The purpose of study was to analyze the participants' opinions concerning the effectiveness of 6 denture adhesives (DA). The study group included 60 participants. Criteria for selecting the patients were as follows: reduced retention and stabilization of maxillary complete dentures and xerostomia. These features were evaluated on basis of clinical examination and standard sialometry tests (u-SFR). Retention of maxillary dentures was scored by modified Kapur index before application of DA. All participants were divided randomly into 6 groups regarding the use of the 6 DA during a 6-month period. After this time, participants completed an HRQL questionnaire. DA noticeably improved retention and stabilization of maxillary complete dentures. DA in the glue form had the best retention effectiveness in participants with xerostomia. These materials are difficult to clean from the denture base. The data are presented in tables and figures. The results of the study collected positive influence of adhesives on retention of dentures in xerostomia patients. The cleaning dentures and denture bearing tissues was difficult. DA help in the use of prostheses, but it is also necessary for the treatment of the causes and symptoms of xerostomia.

  8. Accuracy of Digitally Fabricated Wax Denture Bases and Conventional Completed Complete Dentures.

    PubMed

    Stawarczyk, Bogna; Lümkemann, Nina; Eichberger, Marlis; Wimmer, Timea

    2017-12-19

    The purpose of this investigation was to analyze the accuracy of digitally fabricated wax trial dentures and conventionally finalized complete dentures in comparison to a surface tessellation language (STL)-dataset. A generated data set for the denture bases and the tooth sockets was used, converted into STL-format, and saved as reference. Five mandibular and 5 maxillary denture bases were milled from wax blanks and denture teeth were waxed into their tooth sockets. Each complete denture was checked on fit, waxed onto the dental cast, and digitized using an optical laboratory scanning device. The complete dentures were completed conventionally using the injection method, finished, and scanned. The resulting STL-datasets were exported into the three-dimensional (3D) software GOM Inspect. Each of the 5 mandibular and 5 maxillary complete dentures was aligned with the STL- and the wax trial denture dataset. Alignment was performed based on a best-fit algorithm. A three-dimensional analysis of the spatial divergences in x -, y - and z -axes was performed by the 3D software and visualized in a color-coded illustration. The mean positive and negative deviations between the datasets were calculated automatically. In a direct comparison between maxillary wax trial dentures and complete dentures, complete dentures showed higher deviations from the STL-dataset than the wax trial dentures. The deviations occurred in the area of the teeth as well as in the distal area of the denture bases. In contrast, the highest deviations in both the mandibular wax trial dentures and the mandibular complete dentures were observed in the distal area. The complete dentures showed higher deviations on the occlusal surfaces of the teeth compared to the wax dentures. Computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated wax dentures exhibited fewer deviations from the STL-reference than the complete dentures. The deviations were significantly greater in the vicinity of the denture teeth area and the bases. The conventional transfer of CAD/CAM-fabricated wax dentures into acrylic resin leads to the highest deviations from the STL-reference.

  9. A Clinical Evaluation Denture Adhesives Used by Patients With Xerostomia

    PubMed Central

    Bogucki, Zdzislaw A.; Napadlek, Piotr; Dabrowa, Tomasz

    2015-01-01

    Abstract The purpose of study was to analyze the participants’ opinions concerning the effectiveness of 6 denture adhesives (DA). The study group included 60 participants. Criteria for selecting the patients were as follows: reduced retention and stabilization of maxillary complete dentures and xerostomia. These features were evaluated on basis of clinical examination and standard sialometry tests (u-SFR). Retention of maxillary dentures was scored by modified Kapur index before application of DA. All participants were divided randomly into 6 groups regarding the use of the 6 DA during a 6-month period. After this time, participants completed an HRQL questionnaire. DA noticeably improved retention and stabilization of maxillary complete dentures. DA in the glue form had the best retention effectiveness in participants with xerostomia. These materials are difficult to clean from the denture base. The data are presented in tables and figures. The results of the study collected positive influence of adhesives on retention of dentures in xerostomia patients. The cleaning dentures and denture bearing tissues was difficult. DA help in the use of prostheses, but it is also necessary for the treatment of the causes and symptoms of xerostomia. PMID:25700320

  10. Comparison of the fracture resistances of glass fiber mesh- and metal mesh-reinforced maxillary complete denture under dynamic fatigue loading.

    PubMed

    Im, So-Min; Huh, Yoon-Hyuk; Cho, Lee-Ra; Park, Chan-Jin

    2017-02-01

    The aim of this study was to investigate the effect of reinforcing materials on the fracture resistances of glass fiber mesh- and Cr-Co metal mesh-reinforced maxillary complete dentures under fatigue loading. Glass fiber mesh- and Cr-Co mesh-reinforced maxillary complete dentures were fabricated using silicone molds and acrylic resin. A control group was prepared with no reinforcement (n = 15 per group). After fatigue loading was applied using a chewing simulator, fracture resistance was measured by a universal testing machine. The fracture patterns were analyzed and the fractured surfaces were observed by scanning electron microscopy. After cyclic loading, none of the dentures showed cracks or fractures. During fracture resistance testing, all unreinforced dentures experienced complete fracture. The mesh-reinforced dentures primarily showed posterior framework fracture. Deformation of the all-metal framework caused the metal mesh-reinforced denture to exhibit the highest fracture resistance, followed by the glass fiber mesh-reinforced denture ( P <.05) and the control group ( P <.05). The glass fiber mesh-reinforced denture primarily maintained its original shape with unbroken fibers. River line pattern of the control group, dimples and interdendritic fractures of the metal mesh group, and radial fracture lines of the glass fiber group were observed on the fractured surfaces. The glass fiber mesh-reinforced denture exhibits a fracture resistance higher than that of the unreinforced denture, but lower than that of the metal mesh-reinforced denture because of the deformation of the metal mesh. The glass fiber mesh-reinforced denture maintains its shape even after fracture, indicating the possibility of easier repair.

  11. Comparison of the fracture resistances of glass fiber mesh- and metal mesh-reinforced maxillary complete denture under dynamic fatigue loading

    PubMed Central

    2017-01-01

    PURPOSE The aim of this study was to investigate the effect of reinforcing materials on the fracture resistances of glass fiber mesh- and Cr–Co metal mesh-reinforced maxillary complete dentures under fatigue loading. MATERIALS AND METHODS Glass fiber mesh- and Cr–Co mesh-reinforced maxillary complete dentures were fabricated using silicone molds and acrylic resin. A control group was prepared with no reinforcement (n = 15 per group). After fatigue loading was applied using a chewing simulator, fracture resistance was measured by a universal testing machine. The fracture patterns were analyzed and the fractured surfaces were observed by scanning electron microscopy. RESULTS After cyclic loading, none of the dentures showed cracks or fractures. During fracture resistance testing, all unreinforced dentures experienced complete fracture. The mesh-reinforced dentures primarily showed posterior framework fracture. Deformation of the all-metal framework caused the metal mesh-reinforced denture to exhibit the highest fracture resistance, followed by the glass fiber mesh-reinforced denture (P<.05) and the control group (P<.05). The glass fiber mesh-reinforced denture primarily maintained its original shape with unbroken fibers. River line pattern of the control group, dimples and interdendritic fractures of the metal mesh group, and radial fracture lines of the glass fiber group were observed on the fractured surfaces. CONCLUSION The glass fiber mesh-reinforced denture exhibits a fracture resistance higher than that of the unreinforced denture, but lower than that of the metal mesh-reinforced denture because of the deformation of the metal mesh. The glass fiber mesh-reinforced denture maintains its shape even after fracture, indicating the possibility of easier repair. PMID:28243388

  12. Influence of Palatal Coverage and Implant Distribution on Denture Strain in Maxillary Implant Overdentures.

    PubMed

    Takahashi, Toshihito; Gonda, Tomoya; Tomita, Akiko; Mizuno, Yoko; Maeda, Yoshinobu

    2016-01-01

    As maxillary implant overdentures are being increasingly used in clinical practice, prosthodontic complications related to these dentures are also reported more often. The purpose of this study was to examine the influence of palatal coverage and implant distribution on the shear strain of maxillary implant overdentures. A maxillary edentulous model with implants inserted in the anterior, premolar, and molar areas was fabricated. Two kinds of experimental overdentures, with and without palatal coverage, were also fabricated, and two strain gauges were attached at the midline of the labial and palatal sides. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the shear strain in each denture was compared by analysis of variance (P = .05). In all situations, the shear strain in palateless dentures was significantly higher than in dentures with palate on both sides (P < .05). In dentures with palate, the shear strain was lower when anterior implants were present. Palateless maxillary implant overdentures exhibited much higher strain than overdentures with palate regardless of the implant distribution; this may cause more prosthodontic and implant complications. The most favorable configuration to prevent complications in maxillary implant overdentures was palatal coverage that was supported by more than four widely distributed implants.

  13. Full Mouth Oral Rehabilitation by Maxillary Implant Supported Hybrid Denture Employing a Fiber Reinforced Material Instead of Conventional PMMA.

    PubMed

    Qamheya, Ala Hassan A; Yeniyol, Sinem; Arısan, Volkan

    2015-01-01

    Many people have life-long problems with their dentures, such as difficulties with speaking and eating, loose denture, and sore mouth syndrome. The evolution of dental implant supported prosthesis gives these patients normal healthy life for their functional and esthetic advantages. This case report presents the fabrication of maxillary implant supported hybrid prosthesis by using Nanofilled Composite (NFC) material in teeth construction to rehabilitate a complete denture wearer patient.

  14. Full Mouth Oral Rehabilitation by Maxillary Implant Supported Hybrid Denture Employing a Fiber Reinforced Material Instead of Conventional PMMA

    PubMed Central

    Qamheya, Ala Hassan A.; Arısan, Volkan

    2015-01-01

    Many people have life-long problems with their dentures, such as difficulties with speaking and eating, loose denture, and sore mouth syndrome. The evolution of dental implant supported prosthesis gives these patients normal healthy life for their functional and esthetic advantages. This case report presents the fabrication of maxillary implant supported hybrid prosthesis by using Nanofilled Composite (NFC) material in teeth construction to rehabilitate a complete denture wearer patient. PMID:26557392

  15. Two-Implant-Supported Mandibular Overdentures: Do Clinical Denture Quality and Inter-Implant Distance Affect Patient Satisfaction?

    PubMed

    Alfadda, Sara A; Al Amri, Mohammad D; Al-Ohali, Amal; Al-Hakami, Arwa; Al-Madhi, Noura

    To investigate the following three null hypotheses in patients rehabilitated with a mandibular overdenture supported by two unsplinted implants: (1) patient satisfaction is not related to the clinical quality of the dentures; (2) inter-implant distance (IID) has no effect on the clinical quality of the dentures; and (3) IID does not influence patient satisfaction. Forty edentulous patients who were rehabilitated with a two-implant-supported mandibular overdenture participated in the study. Independent investigators evaluated the dentures on the basis of five clinical criteria using the validated Denture Quality Evaluation Form, and the patients completed the validated Denture Satisfaction Scale. Irreversible hydrocolloid impressions of the mandible were made and poured immediately in die stone. The IID was measured by adapting an orthodontic wire to the mandibular alveolar ridge crest, extending from the center of one implant to the center of the other. Spearman correlation analyses were used to identify possible correlations, with a significance level set at P < .05. The clinicians' overall mean rating of the clinical quality of the dentures was 91.5% (standard deviation 6.27%). The stability of the mandibular overdenture and of the maxillary conventional complete denture was significantly related to satisfaction (r = 0.389 and r = 0.44, respectively). Significant associations were found between the mandibular stability items and satisfaction with both maxillary and mandibular dentures. The stability of the maxillary denture was significantly associated with patient satisfaction with mandibular denture retention, stability, and comfort. None of the 12 denture satisfaction items were significantly associated with IID. Similarly, IID did not have an effect on the quality of either denture in terms of retention, stability, or occlusion. Denture stability was the feature that had the most influence on patient satisfaction with the mandibular overdenture and with the maxillary conventional denture. IID had no effect on the clinical quality of either denture and did not influence patient satisfaction.

  16. Comparison of retention between maxillary milled and conventional denture bases: A clinical study.

    PubMed

    AlHelal, Abdulaziz; AlRumaih, Hamad S; Kattadiyil, Mathew T; Baba, Nadim Z; Goodacre, Charles J

    2017-02-01

    Clinical studies comparing the retention values of milled denture bases with those of conventionally processed denture bases are lacking. The purpose of this clinical study was to compare the retention values of conventional heat-polymerized denture bases with those of digitally milled maxillary denture bases. Twenty individuals with completely edentulous maxillary arches participated in this study. Definitive polyvinyl siloxane impressions were scanned (iSeries; Dental Wings), and the standard tessellation language files were sent to Global Dental Science for the fabrication of a computer-aided design and computer-aided manufacturing (CAD-CAM) milled denture base (group MB) (AvaDent). The impression was then poured to obtain a definitive cast that was used to fabricate a heat-polymerized acrylic resin denture base resin (group HB). A custom-designed testing device was used to measure denture retention (N). Each denture base was subjected to a vertical pulling force by using an advanced digital force gauge 3 times at 10-minute intervals. The average retention of the 2 fabrication methods was compared using repeated ANOVA (α=.05). Significantly increased retention was observed for the milled denture bases compared with that of the conventional heat-polymerized denture bases (P<.001). The retention offered by milled complete denture bases from prepolymerized poly(methyl methacrylate) resin was significantly higher than that offered by conventional heat- polymerized denture bases. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  17. Influence of Palatal Coverage and Implant Distribution on Implant Strain in Maxillary Implant Overdentures.

    PubMed

    Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu

    2016-01-01

    Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.

  18. Changes in the edentulous maxilla with ball and telescopic attachments of implant-retained mandibular overdentures: a 4-year retrospective study.

    PubMed

    Elsyad, Moustafa Abdou; Khairallah, Ahmed Samir; Shawky, Ahmad Fathalla

    2013-07-01

    This retrospective study investigated the clinical and radiographic changes in the edentulous maxilla in patients with either ball or telescopic attachments of implantretained mandibular overdentures. Thirty-two completely edentulous patients (21 males and 11 females) received two implants in the canine region of the mandible. New maxillary complete dentures and mandibular overdentures were fabricated. Overdentures were connected to the implants either with ball (group 1, n = 16) or telescopic (group 2, n = 16) attachments. Retention and stability of the maxillary denture as well as mucosal changes of the maxillary ridge were recorded after 4 years of denturewearing. Traced rotational tomograms were used for measurements of maxillary alveolar bone loss. The proportional value between bone areas and areas of reference not subject to resorption was expressed as a ratio (R). Change in R immediately before (T0) and after 4 years (T4) of overdenture insertion was calculated for the anterior and posterior regions of the maxilla. After 4 years of denture-wearing, maxillary denture retention was significantly higher in group 1 than in group 2, while occurrence of flabby ridges was significantly higher in group 2 than in group 1. The change in R of the anterior region of the maxilla was significantly higher than the change in the posterior region in both groups. Group 2 showed significant anterior residual ridge resorption compared to group 1. Telescopic attachments for implant-retained mandibular overdentures are associated with increased maxillary ridge resorption and flabbiness, and decreased maxillary denture retention when compared to ball attachments.

  19. Efficacy of denture adhesives in maxillary dentures using gnathodynamometry: a comparative study.

    PubMed

    Polyzois, Gregory; Lagouvardos, Panagiotis; Frangou, Maria; Stefaniotis, Theodoros

    2011-07-01

    The purpose of this study was to investigate the effect of four commercially available denture adhesives on the incisal and premolar dislodgement forces of maxillary complete dentures by using an electronic and disposable gnathodynamometer and compare the measured incisal forces for differences. This study was conducted with 12 complete maxillary denture wearers. Four commercially available denture adhesives Super Corega(®), Corega Ultra(®), Super Corega Powder(®) and Fittydent Cationic(®) were investigated. Testing protocol and sequence included baseline measurements without adhesives (control) for previous and new dentures and then replications of measurements with the four adhesives. Maximum dislodgement forces were recorded in two sites between central incisors and the left 2nd premolars by using an electronic and disposable gnathodynamometer. To estimate the effect of the different adhesives on the dislodgement forces, data were analyzed by a 2- and 3-way ANOVA, while for estimating the agreement of the two devices a Bland-Altman and Mountain plots were used. ANOVAs indicated significant differences between adhesives (p < 0.05), denture types (p < 0.05) and biting sites (p < 0.05) with both devices. Bland-Altman plot and Mountain plots indicated a poor agreement of the two devices. It was concluded that denture adhesives increase the denture dislodgement forces, but with differences among them. The two devices do not highly agree with each other, but each one alone is useful in estimating dislodgement forces in clinical practice and research.

  20. A Simplified Technique to Measure Plaque on the Intaglio Surfaces of Complete Dentures.

    PubMed

    Almas, Khalid; Salameh, Ziad; Kutkut, Ahmad; Al Doubali, Ahmad

    2015-04-01

    The main aim of this study was to develop a simplified quantitative denture plaque index that could help dentists to motivate denture patients to maintain optimal oral hygiene. The secondary aim was to assess specific areas of dentures more prone to accumulate plaque and subjects' oral hygiene habits related to their dentures. One hundred subjects who wore maxillary and/or mandibular complete dentures for at least one year were included in the study as a powered sample. Fifteen females and 85 males, age range 45-75 years, were recruited. The study was carried out at King Saud University (KSU), College of Dentistry. A plaque disclosing solution was used to assess the plaque covered areas of denture. A quantitative percentage (10 x 10%) score index was developed by assessing plaque scores from digital images of intaglio surfaces of the dentures. The weighted kappa method was used to assess inter-examiner agreement in the main study. The new denture plaque index was identified as ASKD-DPI (Almas, Salameh, Kutkut, and Doubali-Denture Plaque Index). It ranged from 0 - 100%, and reflected the percentage of the intaglio surfaces of maxillary and mandibular complete dentures that contained plaque. It also classified quantitative percentages: 30 subjects ranged from 0 - 30% (low DPI), 50 subjects ranged from 31 - 70% (moderate DPI), and 20 subjects ranged from 71 - 100% (high DPI) denture plaque score. A simplified denture plaque index (ASKD-DPI) technique was developed and tested in this study. ASKD-DPI may be used for evaluating denture plaque scores, monitoring denture hygiene, and measuring compliance of patients regarding plaque control for complete dentures.

  1. A novel design solution to the fraenal notch of maxillary dentures.

    PubMed

    White, J A P; Bond, I P; Jagger, D C

    2013-09-01

    This study investigates a novel design feature for the fraenal notch of maxillary dentures, using computational and experimental methods, and shows that its use could significantly increase the longevity of the prosthesis. A two-step process can be used to create the design feature with current denture base materials, but would be highly dependent on the individual skill of the dental technician. Therefore, an alternative form of manufacture, multi-material additive layer manufacture (or '3D printing'), has been proposed as a future method for the direct production of complete dentures with multi-material design features.

  2. Improving mechanical properties of maxillary complete dentures through a bioinspired engineering design.

    PubMed

    White, James A P; Bond, Ian P; Jagger, Daryll C

    2011-01-01

    This study investigated how ribbed design features, including palatal rugae, may be used to significantly improve the structural performance of a maxillary denture under load. A computer-aided design model of a generic maxillary denture, incorporating various rib features, was created and imported into a finite element analysis program. The denture and ribbed features were assigned the material properties of standard denture acrylic resin, and load was applied in two different ways: the first simulating a three-point flexural bend of the posterior section and the second simulating loading of the entire palatal region. To investigate the combined use of ribbing and reinforcement, the same simulations were repeated with the ribbed features having a Young modulus two orders of magnitude greater than denture acrylic resin. For a prescribed load, total displacements of tracking nodes were compared to those of a control denture (without ribbing) to assess relative denture rigidity. When subjected to flexural loading, an increase in rib depth was seen to result in a reduction of both the transverse displacement of the last molar and vertical displacement at the centerline. However, ribbed features assigned the material properties of denture acrylic resin require a depth that may impose on speech and bolus propulsion before significant improvements are observed. The use of ribbed features, when made from a significantly stiffer material (eg, fiber-reinforced polymer) and designed to mimic palatal rugae, offer an acceptable method of providing significant improvements in rigidity to a maxillary denture under flexural load.

  3. Rehabilitation of maxillary arch with attachment-retained mesh-reinforced single complete denture

    PubMed Central

    Vamsi Krishna, C H; Rao, A Kaleshwar; Sekhar, N Chandra; Shastry, Y Mahadev

    2014-01-01

    Fabrication of conventional complete dentures was one of the most commonly advised treatment options to mange edentulous patients since many years. One of the commonly encountered challenging tasks in prosthodontics is a clinical situation in which patients have maxillary completely edentulous arches opposing mandibular natural dentition. This situation can be effectively managed by retaining some of the natural teeth as overdenture abutments. Tooth supported overdenture retained by attachments will improve retention, support and stability, and reduces rate of ridge resorption along with psychological benefits to the patients by providing tactile sensation. The present case report describes management of patients with edentulous maxillary arch opposing natural mandibular dentition-rehabilitated attachment-retained mesh-reinforced overdenture. PMID:24574522

  4. Rehabilitation of maxillary arch with attachment-retained mesh-reinforced single complete denture.

    PubMed

    Vamsi Krishna, C H; Rao, A Kaleshwar; Sekhar, N Chandra; Shastry, Y Mahadev

    2014-02-26

    Fabrication of conventional complete dentures was one of the most commonly advised treatment options to mange edentulous patients since many years. One of the commonly encountered challenging tasks in prosthodontics is a clinical situation in which patients have maxillary completely edentulous arches opposing mandibular natural dentition. This situation can be effectively managed by retaining some of the natural teeth as overdenture abutments. Tooth supported overdenture retained by attachments will improve retention, support and stability, and reduces rate of ridge resorption along with psychological benefits to the patients by providing tactile sensation. The present case report describes management of patients with edentulous maxillary arch opposing natural mandibular dentition-rehabilitated attachment-retained mesh-reinforced overdenture.

  5. Different types of antagonists modify the outcome of complete denture renewal.

    PubMed

    Berteretche, Marie Violaine; Frot, Amélie; Woda, Alain; Pereira, Bruno; Hennequin, Martine

    2015-01-01

    The effect of renewing removable dentures on masticatory function was evaluated according to the occlusion offered by different types of mandibular arches. Twenty-eight patients with complete maxillary dentures were subdivided into three groups in terms of mandibular dentition type: dentate, partial denture, and complete denture. The participants were observed before and 8 weeks after maxillary denture renewal. The mandibular denture was also renewed in the partial and complete denture groups. The participants masticated carrots, peanuts, and three model foods of different hardnesses. The particle size distribution of the boluses obtained from natural foods was characterized by the median particle size (d50) in relation to the masticatory normative indicator (MNI). Chewing time (CT), number of chewing cycles (CC), and chewing frequency (CF) were video recorded. A self-assessment questionnaire for oral health-related quality of life (Geriatric Oral Health Assessment Index [GOHAI]) was used. Statistical analyses were carried out with a mixed model. Renewal of the dentures decreased d50 (P < .001). The number of participants with d50 values above the MNI cutoff decreased from 12 to 2 after renewal. Renewal induced an increase in mean CF while chewing model foods (P < .001). With all foods, renewal tended to affect CT, CC, and CF differently among the three groups (statistically significant renewal Å~ group interactions). The GOHAI score increased significantly for all groups. Denture renewal improves masticatory function. The complete denture group benefited least from renewal; the dentate group benefited most. This study confirmed the usefulness of denture renewal for improving functions and oral health- related quality of life.

  6. Light weight dentures: An innovative technique.

    PubMed

    Gundawar, Sham; Zamad, Aakanksha; Gundawar, Sneha

    2014-01-01

    Retention, stability and support are the basic principles on which the success of a complete denture relies. The severely resorbed maxillary and mandibular edentulous arches that are narrow and constricted with increased interarch space provide decreased support, retention and stability. To decrease the leverage, reduction in the weight of the prosthesis was recommended and also found beneficial. This article describes a simple procedure to reduce the weight of maxillary complete denture by use of an autopolymerizing acrylic resin shell which is incorporated during the packing stage. This method has the advantage of being easy and requires very little additional time. Hollow maxillary complete denture considerably reduces the weight of the prosthesis, which in turn prevents transmission of detrimental forces by reducing leverage action. This results in increased retention and stability and up to some extent it also preserves the existing residual alveolar ridge. The technique uses a clear matrix of trial denture to facilitate shaping of dough spacer to ensure an even thickness of acrylic to resist deformation and prevent seepage of saliva into the cavity making this technique more predictable. An autopolymerizing acrylic resin shell which creates hollow space and also has strength. Technique is simple to execute, easy economical and matching the shade of autopolymerizing acrylic resin with heat cures acrylic resin enhances esthetics. Light weight hollow dentures provide healthy and comfortable living for the geriatric edentulous patient.

  7. Complete denture biofilm after brushing with specific denture paste, neutral soap and artificial saliva.

    PubMed

    Paranhos, Helena de Freitas Oliveira; Salles, Antônio Eduardo Sparça; Macedo, Leandro Dorigan de; Silva-Lovato, Cláudia Helena da; Pagnano, Valéria Oliveira; Watanabe, Evandro

    2013-01-01

    This study compared the levels of biofilm in maxillary and mandibular complete dentures and evaluated the number of colony-forming units (cfu) of yeasts, after using auxiliary brushing agents and artificial saliva. Twenty-three denture wearers with hyposalivation and xerostomia were instructed to brush the dentures 3 times a day during 3 weeks with the following products: Corega Brite denture dentifrice, neutral liquid soap, Corega Brite combined with Oral Balance (artificial saliva) or tap water. For biofilm quantification, the internal surfaces of the dentures were disclosed, photographed and measured using a software. For microbiological analysis, the biofilm was scrapped off, and the harvested material was diluted, sown in CHROMagar™ Candida and incubated at 37°C for 48 h. Data were analyzed statistically by two-way ANOVA and Tukey's test (α=0.05). Mandibular dentures presented a mean biofilm percentage (µ=26.90 ± 21.10) significantly greater than the maxillary ones (µ=18.0 ± 15.0) (p<0.05). Brushing using Corega Brite combined with Oral Balance (µ=15.87 ± 18.47) was more effective (p<0.05) than using the denture dentifrice (µ=19.47 ± 17.24), neutral soap (µ=23.90 ± 18.63) or tap water (control; µ=32.50 ± 20.68). For the microbiological analysis, the chi-square test did not indicate significant difference between the hygiene products for either type of denture. The more frequently isolated species of yeasts were C. albicans, C. tropicalis and C. glabrata. In conclusion, mandibular dentures had more biofilm formation than maxillary ones. Denture brushing with Corega Brite dentifrice combined with the use of Oral Balance was the most effective method for reduction of biofilm levels, but the use of products did not show difference in yeast cfu counts.

  8. Remedy for Repeated Implant Retained Denture Fracture-A Challenging Case Report

    PubMed Central

    Reddy M, Ramu; Metta, Kiran Kumar; Charry N, Sudheer; B, Chittaranjan

    2014-01-01

    The most common site of fracture in a maxillary or a mandibular complete denture is along an anteroposterior line that coincides with the labial notch in in the denture which used to provide the frenum relief. Osseointegrated implants have been a boon to the patients who are completelly edentulous and are not satisfied with the conventional removable complete denture approach.Implant supported dentures have proven to provide superior retention and support for removable complete dentures. Nevertheless, fracture of the denture bases is a common complication of implant-supported mandibular overlay dentures,ecspecially when the artificial denture is opposing natural dentition. This article describes and illustrates a method of reinforcing implant-supported mandibular overdentures to overcome this problem. PMID:25584333

  9. Do flexible acrylic resin lingual flanges improve retention of mandibular complete dentures?

    PubMed Central

    Ahmed Elmorsy, Ayman Elmorsy; Ahmed Ibraheem, Eman Mostafa; Ela, Alaa Aboul; Fahmy, Ahmed; Nassani, Mohammad Zakaria

    2015-01-01

    Objectives: The aim of this study was to compare the retention of conventional mandibular complete dentures with that of mandibular complete dentures having lingual flanges constructed with flexible acrylic resin “Versacryl.” Materials and Methods: The study sample comprised 10 completely edentulous patients. Each patient received one maxillary complete denture and two mandibular complete dentures. One mandibular denture was made of conventional heat-cured acrylic resin and the other had its lingual flanges made of flexible acrylic resin Versacryl. Digital force-meter was used to measure retention of mandibular dentures at delivery and at 2 weeks and 45 days following denture insertion. Results: The statistical analysis showed that at baseline and follow-up appointments, retention of mandibular complete dentures with flexible lingual flanges was significantly greater than retention of conventional mandibular dentures (P < 0.05). In both types of mandibular dentures, retention of dentures increased significantly over the follow-up period (P < 0.05). Conclusions: The use of flexible acrylic resin lingual flanges in the construction of mandibular complete dentures improved denture retention. PMID:26539387

  10. Effects of Reinforcement on Denture Strain in Maxillary Implant Overdentures: An In Vitro Study Under Various Implant Configurations.

    PubMed

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    Maxillary implant overdentures are often designed without palatal coverage to maximize wearer comfort. Although palateless dentures have been reported to be less rigid than conventional dentures, and require reinforcement to prevent complications, there is little documentation about the effects of such reinforcement. The purpose of this study was to examine the effects of reinforcement on the strain on maxillary implant overdentures supported by implants in a variety of configurations. A maxillary edentulous model with implants inserted in the anterior, premolar, and molar area was fabricated. Five types of experimental overdentures, with and without reinforcement, were fabricated, and two strain gauges were attached at the anterior midline of the labial and palatal sides. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the shear strain on the denture was measured. The measurements were compared using the Kruskal-Wallis test (P = .05). On both the labial and palatal sides, the strain on the palateless dentures with reinforcement was significantly lower than the strain on palateless dentures without reinforcement in all implant configurations (P < .05). The labial strain on the palateless dentures with reinforcement was almost as low as the labial strain on dentures with palatal coverage in most implant configurations. Reinforcement of a palateless implant overdenture with residual ridge reinforcement and a palatal bar could reduce the strain in the anterior midline to almost the same level as a denture with palatal coverage. This type of reinforcement may prevent prosthetic and implant complications.

  11. Does the nature of the definitive impression material influence the outcome of (mandibular) complete dentures?

    PubMed

    McCord, J Fraser; McNally, Lisa M; Smith, Philip W; Grey, Nicholas J A

    2005-09-01

    The effects of impression materials on the outcome of complete dentures are poorly understood. This double-blind cross-over randomized controlled trial investigated eleven adult edentulous patients. Each received a maxillary denture and three mandibular dentures (which differed only in the three materials used to record the definitive impressions). The three mandibular dentures were given in a random order. Patients' opinions of each denture were recorded using a Linear Analogue Scale. There was a statistically-significant difference between the outcome of the dentures constructed when zinc-oxide eugenol was used, this material being least favoured (p < 0.001). It would therefore appear that care should be exercised when selecting impression materials when constructing mandibular complete dentures.

  12. The influence of resilient liner and clip attachments for bar-implant-retained mandibular overdentures on opposing maxillary ridge. A 5-year randomised clinical trial.

    PubMed

    Elsyad, M A; Ashmawy, T M; Faramawy, A G

    2014-01-01

    This study aimed to compare the influence of resilient liner and clip attachments for bar-implant-retained mandibular overdentures on opposing maxillary ridge after 5 years of denture wearing. Thirty edentulous male patients (mean age 62·5 years) received two implants in the anterior mandible after being allocated into two equal groups using balanced randomisation. After 3 months, implants were connected with resilient bars. New maxillary complete dentures were then constructed, and mandibular overdentures were retained to the bars with either clips (group I, GI) or silicone resilient liners (group II, GII). The prosthetic and soft tissue complications of the maxillary dentures were recorded 6 months (T6 m ), 1 year (T1), 3 years (T3) and 5 years (T5) after overdenture insertion. Traced rotational tomograms were used for measurements of maxillary alveolar bone loss. The proportional value between bone areas and areas of reference not subject to resorption was expressed as a ratio (R). Change in R immediately before (T0) and after 5 years (T5) of overdenture insertion was calculated. Maxillary denture relining times and frequency of flabby anterior maxillary ridge occurred significantly more often in GI compared with GII. The change of R in anterior part of maxilla was significantly higher than change of R in posterior part in both groups. GI showed significant resorption of anterior residual ridge compared with GII. Relining times and frequencies of flabby ridge were significantly correlated with change in R. Within the limitations of this study, resilient liner attachments for bar-implant-retained mandibular overdentures are associated with decreased resorption and flabbiness of maxillary anterior residual ridge and fewer maxillary denture relining times when compared with clip attachments. © 2013 John Wiley & Sons Ltd.

  13. Influence of inner circular sealing area impression method on the retention of complete dentures.

    PubMed

    Wang, Cun-Wei; Shao, Qi; Sun, Hui-Qiang; Mao, Meng-Yun; Zhang, Xin-Wei; Gong, Qi; Xiao, Guo-Ning

    2015-01-01

    The aims of the present study were to describe an impression method of "inner circular sealing area" and to evaluate the effect of the method on retention, aesthetics and comfort of complete dentures, which lack labial base for patients with maxillary protrusions. Three patients were subjected to the experiment, and two sets of complete maxillary dentures were made for each patient; the first set was made without labial base via an inner circular sealing area method (experimental group) and the second had an intact base that was made with conventional methods (control group). Retention force tests were implemented with a tensile strength assessment device to assess the retention and a visual analogue scale (VAS) was used to evaluate the comfort between the two groups. Results showed larger retention force, better aesthetics and more comfort in the experimental group. The improved two-step impression method formed an inner circular sealing area that prevented damage to the peripheral border seal effect of the denture caused by incomplete bases and obtained better denture retention.

  14. CAD/CAM complete dentures: a review of two commercial fabrication systems.

    PubMed

    Kattadiyil, Mathew T; Goodacre, Charles J; Baba, Nadim Z

    2013-06-01

    The use of computer-aided design and computer-aided manufacturing (CAD/CAM) has become available for complete dentures through the AvaDent and Dentca systems. AvaDent uses laser scanning and computer technology. Teeth are arranged and bases formed using proprietary software.The bases are milled from prepolymerized pucks of resin. Dentca uses computer software to produce virtual maxillary and mandibular edentulous ridges, arrange the teeth and form bases. The dentures are fabricated using a conventional processing technique.

  15. Prosthodontic management of worn dentition in pediatric patient with complete overlay dentures: a case report

    PubMed Central

    Rastogi, Jyoti; Jain, Chandni; Singh, Harkanwal Preet

    2012-01-01

    Overlay complete dentures are simple, reversible and economical treatment modality for patients with congenital or acquired disorders that severely affect the tooth development. It satisfies both the esthetic and functional demands where the extraction of teeth is not generally indicated. In pediatric patients, the overlay dentures establish a relatively stable occlusion that improves patient's tolerance to the future treatment procedures for worn dentition. This clinical report highlights the imperative need of appropriate treatment strategy and application of maxillary and mandibular overlay dentures in a pediatric patient who suffered from congenitally mutilated and worn dentition. PMID:23236577

  16. Adaptation and micro-structure of Co-Cr alloy maxillary complete denture base plates fabricated by selective laser melting technique.

    PubMed

    Ye, Ye; Jiao, Ting; Zhu, Jiarui; Sun, Jian

    2018-01-24

    The purpose of the study was to evaluate the adaptation and micro-structure of Co-Cr alloy maxillary complete denture base plates fabricated by the selective laser melting (SLM) technique. Twenty pairs of edentulous casts were randomly and evenly divided into two groups, and manufacturing of the Co-Cr alloy maxillary complete denture base was conducted either by the SLM technique or by the conventional method. The base-cast sets were transversally sectioned into three sections at the distal canines, mesial of the first molars and the posterior palatal zone. The gap between the metal base and cast was measured in these three sections with a stereoscopic microscope, and the data were analysed using t tests. A total of five specimens of 5 mm diameter were fabricated with the Co-Cr alloy by SLM and the traditional casting technology. A scanning electron microscope (SEM) was used to evaluate the differences in microstructure between these specimens. There was no statistical difference between the three sections in all four groups (P > 0.05). At the region of the canines, the clearance value for the SLM Co-Cr alloy group was larger than that of the conventional method group (P < 0.05). At the mesial of the first molar region and the posterior palatal zone, there was no statistical difference between the gaps observed in the two groups (P > 0.05). The SLM Co-Cr alloy has a denser microstructure behaviour and less casting defect than the cast Co-Cr alloy. The SLM technique showed initial feasibility for the manufacture of dental bases of complete dentures, but large sample studies are needed to prove its reliability in clinical applications. The mechanical properties and microstructure of the denture frameworks prepared by selective laser melting indicate that these dentures are appropriate for clinical use.

  17. Using the neutral zone to obtain maxillomandibular relationship records for complete denture patients.

    PubMed

    Alfano, S G; Leupold, R J

    2001-06-01

    A technique for obtaining maxillomandibular registration for complete denture patients is presented. The maxillary rim is formed with the use of conventional techniques. The mandibular rim is made from modeling plastic impression compound on a record base formed by the patient into the neutral zone. The mandibular rim then is reheated, and the patient determines the occlusal vertical dimension by swallowing. An imprint of the maxillary rim is made on the mandibular rim at the occlusal vertical dimension. The posterior extent of the mandibular rim is relieved 1 mm. Orientation notches are placed in both rims, and centric relation is recorded with a fast-setting vinyl polysiloxane material.

  18. Design and fabrication of complete dentures using CAD/CAM technology

    PubMed Central

    Han, Weili; Li, Yanfeng; Zhang, Yue; lv, Yuan; Zhang, Ying; Hu, Ping; Liu, Huanyue; Ma, Zheng; Shen, Yi

    2017-01-01

    Abstract The aim of the study was to test the feasibility of using commercially available computer-aided design and computer-aided manufacturing (CAD/CAM) technology including 3Shape Dental System 2013 trial version, WIELAND V2.0.049 and WIELAND ZENOTEC T1 milling machine to design and fabricate complete dentures. The modeling process of full denture available in the trial version of 3Shape Dental System 2013 was used to design virtual complete dentures on the basis of 3-dimensional (3D) digital edentulous models generated from the physical models. The virtual complete dentures designed were exported to CAM software of WIELAND V2.0.049. A WIELAND ZENOTEC T1 milling machine controlled by the CAM software was used to fabricate physical dentitions and baseplates by milling acrylic resin composite plates. The physical dentitions were bonded to the corresponding baseplates to form the maxillary and mandibular complete dentures. Virtual complete dentures were successfully designed using the software through several steps including generation of 3D digital edentulous models, model analysis, arrangement of artificial teeth, trimming relief area, and occlusal adjustment. Physical dentitions and baseplates were successfully fabricated according to the designed virtual complete dentures using milling machine controlled by a CAM software. Bonding physical dentitions to the corresponding baseplates generated the final physical complete dentures. Our study demonstrated that complete dentures could be successfully designed and fabricated by using CAD/CAM. PMID:28072686

  19. Restoration of facial symmetry in a patient with bell palsy using a modified maxillary complete denture: a case report.

    PubMed

    Bagchi, Gautam; Nath, Dilip Kumar

    2012-01-01

    Permanent facial paralysis can be devastating for a patient. Modern society's emphasis on appearance and physical beauty contributes to this problem and often leads to isolation of patients embarrassed by their appearance. Lagophthalmos with ocular exposure, loss of oral competence with resultant drooling, alar collapse with nasal airway obstruction, and difficulties with mastication and speech production are all potential consequences of facial paralysis. Affected patients are confronted with both a cosmetic defect and the functional deficits associated with loss of facial nerve function. In this case history report, a modified maxillary complete denture permitted a patient with Bell palsy to carry on daily activities with minimal facial distortion, pain, speech difficulty, and associated emotional trauma.

  20. [Preferred sites of accumulation of microbial plaque as shown by the color of the exterior surface of complete dentures].

    PubMed

    Merdes, L; Soueidan, A; Le Bars, P; Tabbi-Aneni, N

    2009-03-01

    The observation of the denture plaque for complete dentures caused many clinical works and researches, since 30 years. Most of the studies were interested, by the prosthetic under-surface. New data show that the polished (exterior) surface on the denture palate is colonized more than hard palate. The aim of our study is to locate the favorite zones of the accumulation of the denture plaque on the level of the suction polished faces of the acrylic resin. We proceeded by immersion during 24 hours of 62 used full dentures belongs to 33 patients, with mucous membranes of various clinical aspects in a plaque disclosing solution of erythrosine type. The suction faces were divided into several zones of marking. We record 100% of coloring of the interdental zones on the maxillary and mandibular prosthesis. On maxillary prosthesis: 100% of the former and posterior vestibular zones are colored. The bottom of the palate is colored to 67.74%, a rate equivalent to the zones of fractures. On mandibular prosthesis: retromolar and sublingual zones, are colored to 96.77%. The former hall is colored with a rate of 90.32%. The posterior vestibular zone seems the least colored with a rate of 80.64%. The former area of the hall carved in an aesthetic objective is generally colored as well on the maxillary and mandibular prosthesis. We point out that this zone should not be much carved on the level of the area simulating the attached gum. Patients should be always incited to practice a mechanical hygiene, which takes part largely in the evacuation of the denture plaque on prosthetic surfaces. This revealing plaque use should integrate a clinical attitude of good practice, to motivate a patient with prosthetic hygiene or to detect zones of cracks objectifying a mechanical weakness of a prosthesis to be taken again, as well as the checking of the quality of repair joint during a routine control.

  1. Patient satisfaction with maxillary 3-implant overdentures using different attachment systems opposing mandibular 2-implant overdentures.

    PubMed

    Al-Zubeidi, Mohammed I; Alsabeeha, Nabeel H M; Thomson, W Murray; Payne, Alan G T

    2012-05-01

    Patient-based outcomes with maxillary overdentures on a minimum number of implants, opposing mandibular 2-implant overdentures are not evident in the literature. To evaluate patient's satisfaction with maxillary 3-implant overdentures, opposing mandibular 2-implant overdentures, using two different attachment systems over the first 2 years of service. Forty participants wearing mandibular 2-implant overdentures for 3 years were randomly allocated to one of two similar implant system groups to receive maxillary 3-implant overdentures. Twenty participants were allocated to splinted and unsplinted attachment system treatment groups for each system. Patient satisfaction with pre-treatment complete maxillary dentures, with maxillary 3-implant overdentures at baseline and annually for 2 years, was measured using visual analogue scale questionnaires and the oral health impact profiles. Palatal coverage of the maxillary overdentures was reduced at the first annual recall. Data showed significant improvement in pain reduction, comfort, stability, and function variables of the visual analogue scale after treatment. Analysis by prosthodontic design using visual analogue scale showed no significant difference. The total oral health impact profile-14 scores after treatment for all participants, regardless of prosthodontic design, were significantly lower (more satisfied). The overall oral health impact profile-20E score at baseline was significantly higher (more satisfied) compared with pre-treatment conventional maxillary dentures. No significant changes were observed in the first or second years compared with baseline results. Twenty-two participants (84.6%) preferred reduced palatal coverage, regardless of prosthodontic design, after 1 year. Twenty participants (76.9%) still preferred reduced palatal coverage at the end of the second year. The provision of maxillary 3-implant overdentures to oppose mandibular 2-implant overdentures significantly improve levels of patient satisfaction compared with conventional maxillary dentures. © 2011 Wiley Periodicals, Inc.

  2. [The statistical analysis for the use of the 55,787 finished resin teeth].

    PubMed

    Wu, Shu-hong; Yu, Hai-yang; Wang, Lu; Xu, Ling; Xiao, Zhi-li

    2010-08-01

    To analyze the use situation of finished resin teeth for the different location, and to provide reference for manufacturers of finished resin teeth and all the buyers. To analyze the use situation of finished resin teeth in the Dental Laboratory of the Affiliated Hospital of Stomatology of Chongqing Medical University from January 2006 to December 2008 by using statistic methods. During the use of 55,787 finished resin teeth, the study found some rules. (1) The top use of finished resin teeth was D6 with the percentage of 5.31%, and the lowest use of finished resin teeth was D3 with the percentage of 1.94%. (2) Except the maxillary canines and the mandibular lateral incisors, there was no significant difference between the usage of other same name finished resin teeth (P > 0.05). (3) Among all finished resin teeth, the usage of section B exceeded section A, and the usage of maxillary finished resin teeth exceeded mandibular finished resin teeth (P < 0.05). (4) The use of the complete denture and single complete denture was about 1/3 of the total usage of finished resin teeth. (5) Except the use situation of complete denture and single complete denture, the frequency of simultaneously using mandibular left and right central incisors was the most with the percentage of 81.46%, for the frequency of simultaneously using maxillary left and right canines was 43.26% of the total, which was the lowest. There is significant difference in the use frequency of finished resin teeth for different location. For such reason, the manufacturers should produce finished resin teeth pro rata as well as the buyers for their purchase.

  3. Survival of various implant-supported prosthesis designs following 36 months of clinical function.

    PubMed

    Rodriguez, A M; Orenstein, I H; Morris, H F; Ochi, S

    2000-12-01

    The use of endosseous dental implants to replace natural teeth lost to trauma, dental caries, or periodontal disease has become a predictable form of prosthetic treatment since gaining popularity in the early 1980s. While numerous clinical studies have focused on the survival of implants, few address the survival of different prosthesis designs. Beginning in 1991, 882 prostheses supported by more than 2,900 implants (687 patients) were placed by the Department of Veterans Affairs Dental Implant Clinical Research Group (DICRG). These prostheses were divided into five research strata based on arch location. The recommended design for each stratum was: bar-supported overdenture (maxillary completely edentulous); screw-retained hybrid denture (mandibular completely edentulous); screw-retained fixed partial denture (mandibular and maxillary posterior partially edentulous); and cemented single crown (maxillary anterior single tooth). Alternative overdenture designs were utilized in the edentulous arches when the recommended prosthesis could not be fabricated. Prosthesis success rates for the research strata were calculated for an observation time of up to 36 months following prosthesis placement. Success rates for the maxillary edentulous stratum ranged from 94.6% for the bar-retained overdenture supported by five to six fixtures to 81.8% for the cap-retained overdenture. The mandibular edentulous strata produced success rates of 98.1% for the fixed hybrid prosthesis to 91.7% for the cap-retained prosthesis. Success rates for maxillary and mandibular posterior fixed partial dentures were 94.3% and 92.6%, respectively, while the maxillary anterior single-tooth prosthesis yielded a success rate of 98.1% for the 36-month observation period. The recommended prosthesis designs investigated in this study proved to be reliable, with encouraging success rates for an observation period of 36 months following placement.

  4. Mandibular single-implant overdentures: a review with surgical and prosthodontic perspectives of a novel approach.

    PubMed

    Alsabeeha, Nabeel; Payne, Alan G T; De Silva, Rohana K; Swain, Michael V

    2009-04-01

    To review the literature on mandibular single-implant overdentures (opposing complete maxillary dentures), and present surgical and prosthodontic perspectives of a novel approach for this treatment option. An electronic search through the databases of Pubmed, Embase and Medline using the linked key words 'mandibular single implant overdentures' was performed. The search was limited to English language articles published up to August 2008. Hand searches through articles retrieved from the electronic search, peer-reviewed journals and recent conference proceedings were also conducted. A limited number of reports were identified on mandibular single-implant overdentures (opposing maxillary complete dentures). They comprised of case-series reports, short-term prospective trials and current randomized-controlled clinical trials. Different loading protocols with different implant systems have been used, but always with regular diameter implants. Specific anatomical and vascular dangers of the mandibular midline symphysis are identified including a novel surgical approach using a currently available short, wide diameter tapered implant. In addition, the prosthodontic rationale for using a larger attachment system (incorporating a platform switch) for mandibular single-implant overdentures is described. The review reveals that there is a lack of published randomized clinical trials using mandibular single-implant overdentures, opposing maxillary complete dentures. Without the evidence from randomized clinical trials, routine use of this novel approach cannot be recommended, compared with using regular diameter implants and matching attachment systems.

  5. Complications and Clinical Considerations of the Implant-Retained Zirconia Complete-Arch Prosthesis with Various Opposing Dentitions.

    PubMed

    Gonzalez, Jorge; Triplett, Robert G

    To evaluate the performance of the implant-retained zirconia complete-arch prosthesis with various opposing dentitions. The 40 patients included in this retrospective case series study were treated with one or two implant-retained zirconia complete-arch prostheses (ZIRCAP) using the Zirkonzahn protocol. Prettau zirconia frames were created with strategic cutbacks in the structure to extend zirconia incisal coverage of the esthetic anterior sextants and complete monolithic zirconia in the molar areas; subsequent layers of porcelain were applied to nonfunctional and esthetic areas. Patients had three possible occlusal scenarios: (1) maxillary ZIRCAP and mandibular ZIRCAP, (2) maxillary ZIRCAP and mandibular natural dentition, and (3) maxillary ZIRCAP and mandibular conventional hybrid prosthesis. Complications were recorded during follow-up appointments 3, 6, and 12 months after definitive prosthesis delivery. The mean treatment observation period was 33 months. Eight prosthetic complications were noted for the 40 implant-retained zirconia complete-arch prostheses (18.18%), including six cases of minor porcelain chipping and two cases of debonding of the metal insert from the zirconia framework. Maxillary ZIRCAP opposing mandibular ZIRCAP and maxillary ZIRCAP opposing mandibular natural dentition occlusal scenarios presented the same complication ratio of 4. No complications were seen in the maxillary ZIRCAP opposing mandibular conventional hybrid prosthesis group, yet 16 complications were found as denture tooth fractures in 12 mandibular conventional hybrid prostheses (ratio of 0.75). The results indicate that the implant-retained zirconia complete-arch prosthesis offers acceptable performance for use as an alternative to the conventional titanium framework acrylic veneer prosthesis for complete edentulism with a lower incidence of prosthetic complications and fewer maintenance appointments. Chipping of veneering porcelain was the most common complication, but a low incidence was observed in this study. Acrylic denture teeth may represent the weakest link when restoring complete edentulism with a maxillary ZIRCAP and mandibular conventional hybrid prosthesis.

  6. Effect of Attachment Type on Denture Strain in Maxillary Implant Overdentures: Part 1. Overdenture with Palate.

    PubMed

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    This study examined the effects of attachments on strain in maxillary implant overdentures supported by two or four implants. A maxillary edentulous model with implants inserted into anterior, premolar, and molar areas was fabricated, and three types of unsplinted attachments-ball, locator, and magnet-were set on the implants distributed under various conditions. Maxillary experimental dentures were fabricated, and two strain gauges were attached at the anterior midline on the labial and palatal sides. A vertical occlusal load of 98 N was applied and shear strain of the dentures was measured. On both sides, magnet attachments resulted in the lowest shear strain, while ball attachments resulted in the highest shear strain under most conditions. However, differences in shear strain among the three attachment types were not significant when supported by four implants, especially molar implants. Shear strain of the maxillary implant overdenture was lowest when using magnet attachments. Magnet attachments mounted on four implants are recommended to prevent denture complications when using maxillary implant overdentures.

  7. Influence of different base thicknesses on maxillary complete denture processing: linear and angular graphic analysis on the movement of artificial teeth.

    PubMed

    Mazaro, José Vitor Quinelli; Gennari Filho, Humberto; Vedovatto, Eduardo; Amoroso, Andressa Paschoal; Pellizzer, Eduardo Piza; Zavanelli, Adriana Cristina

    2011-09-01

    The purpose of this study was to compare the dental movement that occurs during the processing of maxillary complete dentures with 3 different base thicknesses, using 2 investment methods, and microwave polymerization. A sample of 42 denture models was randomly divided into 6 groups (n = 7), with base thicknesses of 1.25, 2.50, and 3.75 mm and gypsum or silicone flask investment. Points were demarcated on the distal surface of the second molars and on the back of the gypsum cast at the alveolar ridge level to allow linear and angular measurement using AutoCAD software. The data were subjected to analysis of variance with double factor, Tukey test and Fisher (post hoc). Angular analysis of the varying methods and their interactions generated a statistical difference (P = 0.023) when the magnitudes of molar inclination were compared. Tooth movement was greater for thin-based prostheses, 1.25 mm (-0.234), versus thick 3.75 mm (0.2395), with antagonistic behavior. Prosthesis investment with silicone (0.053) showed greater vertical change compared with the gypsum investment (0.032). There was a difference between the point of analysis, demonstrating that the changes were not symmetric. All groups evaluated showed change in the position of artificial teeth after processing. The complete denture with a thin base (1.25 mm) and silicone investment showed the worst results, whereas intermediate thickness (2.50 mm) was demonstrated to be ideal for the denture base.

  8. Effect of water storage on tooth displacement in maxillary complete dentures.

    PubMed

    Consani, Rafael Leonardo Xediek; Mesquita, Marcelo Ferraz; Consani, Simonides; Correr Sobrinho, Lourenço; Sousa-Neto, Manoel Damião

    2006-01-01

    The purpose of this study was to investigate the effect of water storage at 37 degrees C (1 week, 1 month and 3 months) on tooth displacement in maxillary complete dentures. Ten maxillary dentures were constructed with Clássico acrylic resin using the conventional method of packing in metallic flasks. Metallic reference pins were placed in the incisal border of the central incisors (I), labial cusp of the first premolars (PM), and mesiolabial cusp of the second molars (M). Twelve hours after final flask closure, the acrylic resin was cured in water at 74 degrees C for 9 h. The flasks were removed from the thermo-polymerizing unit after water-cooling and the dentures were deflasked, finished and stored in water at a temperature of 37 degrees C for 1 week, 1 month and 3 months. At deflasking and at the water storage intervals, the I-I (incisor to incisor), PM-PM (pre-molar to pre-molar), and M-M (molar to molar) transversal distances, and LI-LM (left incisor to left molar) and RI-RM (right incisor to right molar) anteroposterior distances were measured using an optical microscope with 0.0005 mm accuracy. Data were submitted to ANOVA and Tukey's test (5%). Comparing the evaluation periods for each individual transversal and anteroposterior reference point, no statistically significant differences were observed among deflasking and the water storage intervals for I-I, PM-PM, M-M and RI-RM distances (p>0.05). For LI-LM, however, deflasking values were statistically different from those of 1-week, 1-month and 3-month water storage intervals (p<0.05), which, in turn, did not differ statistically to each other (p>0.05). These results confirm the complexity of tooth displacement in complete dentures. From a clinical standpoint, the difference observed in LI-LM distance after water storage would not be detected by the patients during clinical use.

  9. An overlay partial denture to restore worn mandibular anterior teeth.

    PubMed

    Samant, Asha; DeSciscio, Peter

    2014-01-01

    Restoring worn anterior mandibular teeth is a challenge, especially when teeth are small, esthetics are a concern, the long-term prognosis is questionable, and/or patient finances are an issue. This article describes an alternate treatment for a patient with a collapsed bite, missing posterior mandibular teeth, an ill-fitting complete maxillary denture with poor esthetics, and irregular, worn mandibular anterior teeth.

  10. Oral Rehabilitation of a Severely Resorbed Edentulous Maxilla with Screwed-retained Hybrid Denture Using Cresco System: A Case Report

    PubMed Central

    Turkyilmaz, Ilser; Patel, Neal S.; McGlumphy, Edwin A.

    2008-01-01

    Due to the angulation of maxillary bone as the maxillary bone resorption occurs from a buccal to palatal direction, bucco-lingually tilted implant placement is more likely especially in the posterior maxilla. The aim of this paper was to present a case restored by using a maxillary hybrid denture using Cresco method. A 59-year-old woman with an edentulous maxilla and five missing mandibular teeth was referred for implant treatment. Six months after sinus lift operation, four mandibular implants and six maxillary implants were placed. Due to the bucco-lingual tilt of two implants, the Cresco method was chosen to fabricate the metal framework for the maxillary hybrid denture that was delivered four months after implant placement. The main advantages of the Cresco method are a perfectly passive framework fit and corrected screw access holes. All ten implants placed were considered successful at 1-year recall, and no screw access holes were seen in the buccal part of the maxillary acrylic teeth. It was concluded that such screw-retained maxillary hybrid denture using the Cresco method met the esthetic expectations of a highly demanding patient. PMID:19212552

  11. Cone Beam Computed Tomography Analysis in 3D Position of Maxillary Denture

    PubMed Central

    Jia, Ying; Yang, Hua; Li, Ping; Xiong, Jiangyan; Chen, Bo

    2017-01-01

    Abstract The dynamic correlation between teeth and denture morphology as well as the morphological positions needs to be explored. Methodology 63 adult patients with skeletal class III malocclusions that met the inclusion criteria were enrolled and imaged with Cone Beam Computed Tomography (CBCT), and Digital Imaging and Communications in Medicine (DICOM) data were collected. The torque angle and axial inclination were measured and analyzed for the corona, root, and entire body of every tooth on the maxilla. Results There is a statistically significant difference between the coronal axial inclination/coronal torque angle for the skeletal class III malocclusion cases and Andrew’s six keys of occlusion. On the sagittal plane of the maxillary denture (except that the secondary molar is inclined medial-distally), the remaining teeth are inclined towards the labia with slightly larger angles compared to the normal occlusion. In the coronal direction, the maxillary anterior teeth tend to have a corona that inclines medial-distally, whereas the posterior teeth have a buccal inclination compared to the normal occlusion. Conclusion Sagittal and transversal compensations prevail in maxillary dentures; for the camouflaged treatment design for skeletal class III, there is limited scope of sagittal and transversal movements on the maxillary denture. PMID:29104942

  12. Maxillary overdentures supported by four or six implants in the anterior region: 5-year results from a randomized controlled trial.

    PubMed

    Slot, Wim; Raghoebar, Gerry M; Cune, Marco S; Vissink, Arjan; Meijer, Henny J A

    2016-12-01

    To compare a four- and six-implant maxillary overdenture after an observation period of 5 years. Fifty subjects with functional problems concerning their maxillary denture, who had ample bone volume in the anterior region to place four or six implants, were included and randomly assigned to either group. Implant and overdenture survival, clinical performance, marginal bone loss and patient satisfaction were assessed. Forty-six patients completed the 5-year follow-up. One implant failed in the six implants group (99.2% survival) and none in the four implants group (100% survival). No overdentures had to be replaced during the observation period and the number of complications was limited. Clinical function was good, with no difference in clinical parameters between the groups. Mean marginal bone resorption was 0.50 ± 0.37 and 0.52 ± 0.43 mm in the four and six implant group respectively. In patients with functional complaints of their maxillary denture, bar-supported overdentures on four implants in the anterior maxillary region were not inferior to overdentures supported by six implants after 5 years of function. Implant survival and patient satisfaction were high, clinical parameters favourable, bone loss and complications to the denture were minor in both groups (Clinical trial registration number: NTR2969). © 2016 The Authors. Journal of Clinical Periodontology Published by John Wiley & Sons Ltd.

  13. Biting Force and Muscle Activity in Implant-Supported Single Mandibular Overdentures Opposing Fixed Maxillary Dentition.

    PubMed

    Al-Magaleh, Wafaʼa R; Abbas, Nadia A; Amer, Ashraf A; Abdelkader, Ann A; Bahgat, Basma

    2016-04-01

    This study aimed to investigate the relation between biting force and masticatory muscle activity in patients treated by 3 modalities of single mandibular dentures. Forty implants were placed in 10 patients with completely edentulous mandibles. The study was divided into 3 treatment stages. Initially, each patient received a conventional mandibular complete denture. At the second stage, 4 mandibular implants were placed and the denture was refitted to their abutments. Third stage comprised connecting the denture to the implants through ball attachments. During each treatment stage, maximum biting force and muscle activity were measured during maximum clenching and chewing of soft and hard food. Biting force demonstrated a statistically significant increase by time for the 3 treatment stages. The highest muscle activity was recorded for the conventional denture followed by the implant-supported overdenture without attachment, whereas the lowest values were recorded for the implant-supported overdenture with attachment. Biting force was related mainly to the quality of denture support. Muscle activity was higher in patients with conventional denture than with implant-supported prostheses (with or without attachments).

  14. Effect of Reinforcement Using Stainless Steel Mesh, Glass Fibers, and Polyethylene on the Impact Strength of Heat Cure Denture Base Resin - An In Vitro Study.

    PubMed

    Murthy, H B Mallikarjuna; Shaik, Sharaz; Sachdeva, Harleen; Khare, Sumit; Haralur, Satheesh B; Roopa, K T

    2015-06-01

    The impact strength of denture base resin is of great concern and many approaches have been made to strengthen acrylic resin dentures. The objective of this study was to compare the impact strength of the denture base resin with and without reinforcement and to evaluate the impact strength of denture base resin when reinforced with stainless steel mesh, glass fiber, and polyethylene fibers in the woven form. The specimens (maxillary denture bases) were fabricated using a standard polyvinylsiloxane mold with conventional heat cured polymethyl methacrylate resin. The specimens were divided into four groups (n = 10). Group I specimens or control group were not reinforced. Group II specimens were reinforced with stainless steel mesh and Group III and Group IV specimens were reinforced with three percent by weight of glass fibers and polyethylene fibers in weave form respectively. All the specimens were immersed in water for 1-week before testing. The impact strength was measured with falling weight impact testing machine. One-way analysis of variance and Tukey's post-hoc test were used for statistical analysis. Highest impact strength values were exhibited by the specimens reinforced with polyethylene fibers followed by glass fibers, stainless steel mesh, and control group. Reinforcement of maxillary complete dentures showed a significant increase in impact strength when compared to unreinforced dentures. Polyethylene fibers exhibit better impact strength followed by glass fibers and stainless steel mesh. By using pre-impregnated glass and polyethylene fibers in woven form (prepregs) the impact strength of the denture bases can be increased effectively.

  15. Telescopic Overdenture: A Case Report

    PubMed Central

    Shruthi, C. S.; Poojya, R.; Ram, Swati; Anupama

    2017-01-01

    Patient: This report describes the case of a 68 year old female patient who presented with the chief complaint of difficulty in chewing and poor aesthetics due to missing teeth. The patient was interested in saving the remaining natural teeth and desired minimal tissue coverage from the prosthesis. After consideration of all the factors involved, it was deemed advisable to resort to a palate free maxillary telescopic complete denture and a mandibular removable partial denture. Discussion: Considering the age of the patient and the cost involved, implant supported prosthesis was ruled out as a treatment option for the patient. A telescopic denture was chosen as a favourable treatment option since it overcomes many of the problems posed by conventional complete dentures like progressive bone loss, lower stability and retention, loss of periodontal proprioception and low masticatory efficiency. It also provides minimal tissue coverage and better distribution of forces. Evaluation of occlusion, esthetics, phonetics and comfort after 24 hours, 1 week and 1 month of treatment showed that the patient was happy with the prosthesis and was able to speak and chew well. Conclusion: Telescopic overdentures have better retention and stability as compared to conventional complete dentures. They improve the chewing efficiency, patient comfort and also decrease the alveolar bone resorption. As such they are an excellent alternative to conventional complete denture treatment. PMID:28533736

  16. Telescopic Overdenture: A Case Report.

    PubMed

    Shruthi, C S; Poojya, R; Ram, Swati; Anupama

    2017-03-01

    This report describes the case of a 68 year old female patient who presented with the chief complaint of difficulty in chewing and poor aesthetics due to missing teeth. The patient was interested in saving the remaining natural teeth and desired minimal tissue coverage from the prosthesis. After consideration of all the factors involved, it was deemed advisable to resort to a palate free maxillary telescopic complete denture and a mandibular removable partial denture. Considering the age of the patient and the cost involved, implant supported prosthesis was ruled out as a treatment option for the patient. A telescopic denture was chosen as a favourable treatment option since it overcomes many of the problems posed by conventional complete dentures like progressive bone loss, lower stability and retention, loss of periodontal proprioception and low masticatory efficiency. It also provides minimal tissue coverage and better distribution of forces. Evaluation of occlusion, esthetics, phonetics and comfort after 24 hours, 1 week and 1 month of treatment showed that the patient was happy with the prosthesis and was able to speak and chew well. Telescopic overdentures have better retention and stability as compared to conventional complete dentures. They improve the chewing efficiency, patient comfort and also decrease the alveolar bone resorption. As such they are an excellent alternative to conventional complete denture treatment.

  17. A clinical study to evaluate denture adhesive use in well-fitting dentures.

    PubMed

    Munoz, Carlos A; Gendreau, Linda; Shanga, Gilbert; Magnuszewski, Tabetha; Fernandez, Patricia; Durocher, John

    2012-02-01

    The objective of this study was the assessment of retention and stability and functional benefits of denture adhesive applied to well-fitting and well-made dentures. This was a randomized, crossover study to compare two marketed denture adhesives (test cream, Super Poligrip® Free, and test strip, Super Poligrip® Comfort Seal Strips) and an unmarketed cream adhesive (GlaxoSmith Kline Consumer Healthcare) with no adhesive as the negative control. Thirty-six subjects completed the study. One hour after the application of denture adhesive, retention and stability were measured using the Kapur Index and maxillary incisal bite force. Two hours after application, functional tests were used to assess denture movement and peanut particle migration under the denture. Subjects also rated confidence, comfort, satisfaction with dentures, and denture wobble in conjunction with the functional tests. Denture adhesives significantly (p < 0.05) improved retention and stability of well-fitting dentures. Subjects experienced significantly (p < 0.05) fewer dislodgements while eating an apple after adhesive was applied to dentures. Significant (p < 0.05) increases in subjective ratings of confidence and comfort as well as decreases in denture wobble were associated with the use of adhesive. There was significant (p < 0.05) improvement in satisfaction ratings for cream adhesives. A single application of each denture adhesive was well tolerated. The results of this study provide evidence that use of Super Poligrip® denture adhesives can enhance aspects of performance of complete well-fitting dentures as well as provide increased comfort, confidence, and satisfaction with dentures. © 2011 by the American College of Prosthodontists.

  18. Effect of Reinforcement Using Stainless Steel Mesh, Glass Fibers, and Polyethylene on the Impact Strength of Heat Cure Denture Base Resin - An In Vitro Study

    PubMed Central

    Murthy, H B Mallikarjuna; Shaik, Sharaz; Sachdeva, Harleen; Khare, Sumit; Haralur, Satheesh B; Roopa, K T

    2015-01-01

    Background: The impact strength of denture base resin is of great concern and many approaches have been made to strengthen acrylic resin dentures. The objective of this study was to compare the impact strength of the denture base resin with and without reinforcement and to evaluate the impact strength of denture base resin when reinforced with stainless steel mesh, glass fiber, and polyethylene fibers in the woven form. Materials and Methods: The specimens (maxillary denture bases) were fabricated using a standard polyvinylsiloxane mold with conventional heat cured polymethyl methacrylate resin. The specimens were divided into four groups (n = 10). Group I specimens or control group were not reinforced. Group II specimens were reinforced with stainless steel mesh and Group III and Group IV specimens were reinforced with three percent by weight of glass fibers and polyethylene fibers in weave form respectively. All the specimens were immersed in water for 1-week before testing. The impact strength was measured with falling weight impact testing machine. One-way analysis of variance and Tukey’s post-hoc test were used for statistical analysis. Results: Highest impact strength values were exhibited by the specimens reinforced with polyethylene fibers followed by glass fibers, stainless steel mesh, and control group. Conclusions: Reinforcement of maxillary complete dentures showed a significant increase in impact strength when compared to unreinforced dentures. Polyethylene fibers exhibit better impact strength followed by glass fibers and stainless steel mesh. By using pre-impregnated glass and polyethylene fibers in woven form (prepregs) the impact strength of the denture bases can be increased effectively. PMID:26124604

  19. Masticatory performance of complete denture wearers after using two adhesives: a crossover randomized clinical trial.

    PubMed

    de Oliveira Junior, Norberto Martins; Rodriguez, Larissa Santana; Mendoza Marin, Danny Omar; Paleari, André Gustavo; Pero, Ana Carolina; Compagnoni, Marco Antonio

    2014-11-01

    Masticatory performance analysis of conventional complete denture wearers who use denture adhesives is scarce in the dental literature. The purpose of this study was to assess the effect of the use of 2 denture adhesives on the masticatory performance of conventional complete denture wearers by means of a crossover study. Forty individuals who were edentulous received new maxillary and mandibular complete dentures, and, after an adaptation period, were submitted to masticatory performance analysis without denture adhesive (control). The participants were randomly divided and assigned to 2 protocols: protocol 1, denture adhesive 1 (Ultra Corega cream tasteless) use during the first 15 days, followed by no use of denture adhesive over the next 15 days (washout), and then use of denture adhesive 2 (Ultra Corega powder tasteless) for 15 days; protocol 2, denture adhesive 2 (Ultra Corega powder tasteless) use during the first 15 days, followed by no use of denture adhesive during the next 15 days (washout), and then use of denture adhesive 1 (Ultra Corega cream tasteless) for 15 days. The masticatory performance was assessed immediately after the use of denture adhesive by means of the sieve method, in which participants were instructed to deliberately chew 5 almonds for 20 chewing strokes. Masticatory performance was calculated by the weight of comminuted material that passed through the sieves. Data were analyzed by a 1-way ANOVA for paired samples and the multiple comparison of means by using the Bonferroni test (α=.05). A significant increase in masticatory performance was noted after using the Ultra Corega cream (mean, 32.6%) and Ultra Corega powder (mean, 31.2%) when compared with the control group (mean, 19.8%) (P<.001). No significant difference was found between the 2 denture adhesives evaluated. The use of denture adhesive improved the masticatory performance of conventional complete denture wearers. No difference was found in masticatory performance with the use of cream or powder denture adhesive. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Dimensional change in complete dentures fabricated by injection molding and microwave processing.

    PubMed

    Keenan, Phillip L J; Radford, David R; Clark, Robert K F

    2003-01-01

    Acrylic resin complete dentures undergo dimensional changes during polymerization. Techniques with injection molding and polymerization and microwave polymerization are reported to reduce these changes and thereby improve clinical fit. These dimensional changes need to be quantified. The purpose of this study was to compare differences in dimensional changes of simulated maxillary complete dentures during polymerization and storage in water after injection molding and conventional polymerization, or microwave polymerization against a control of conventionally packed and polymerized simulated maxillary complete dentures. Forty identical maxillary denture bases were prepared in dental wax with anatomic teeth. They were invested and the wax eliminated from the molds. Ten specimens each were randomly assigned to 1 of 4 groups. Group 1 was compression molded and conventionally polymerized; group 2 was injection molded and conventionally polymerized (Success); group 3 was injection molded and microwave polymerized (Acron MC); and group 4 was injection molded and microwave polymerized (Microbase). Intermolar width and changes in vertical dimension of occlusion, were determined after polymerization and after storage in water for 28 days. Measurements in triplicate were made between points scribed on the second molar teeth with a traveling microscope (accurate to 0.005 mm). Vertical dimension of occlusion was measured between points scribed on the upper and lower members of an articulator by use of an internal micrometer (accurate to 0.05 mm). Data were analyzed by use of a 1-way analysis of variance with Tukey post-hoc contrasts (P <.05). Polymerization contractions (intermolar widths) for each group were: group 1, -0.24%; group 2, -0.27%; group 3, -0.35%; and group 4, -0.37%. The Microbase specimens had greater shrinkage than conventionally polymerized specimens, but there were no significant differences between the groups. All injection methods had less postpolymerization increase in vertical dimension of occlusion (0.63 to 0.41 mm) than the conventional Trevalon control (0.74 mm), but only group 4 was significantly different (P<.004). After storage in water for 28 days, all specimens increased in vertical dimension of occlusion (0.10% to 0.16%) from polymerization techniques, but there were no significant differences between groups. Within the limitations of this study, injection molding resulted in a slightly less increase of vertical dimension of occlusion than conventional polymerization techniques, the difference being significant for Microbase compared with the conventional Trevalon control.

  1. Evaluation of palatal plate thickness of maxillary prosthesis on phonation- a comparative clinical study.

    PubMed

    Zakkula, Srujana; B, Sreedevi; Anne, Gopinadh; Manne, Prakash; Bindu O, Swetha Hima; Atla, Jyothi; Deepthi, Sneha; Chaitanya A, Krishna

    2014-04-01

    Prosthodontic treatment involves clinical procedures which influence speech performance directly or indirectly. Prosthetic rehabilitation of missing teeth with partial or complete maxillary removable dentures influences the individual voice characteristics like Phonation, resonance etc. To evaluate the effect of Acrylic palatal plate thickness (1mm-3mm) of maxillary prosthesis on phonation. Twelve subjects were selected randomly between the age group of 20-25 years who have full complement of teeth and have no speech problems. Speech evaluation was done under four experimental conditions i.e. Without any experimental acrylic palatal plate (control), with experimental acrylic palatal plates of thickness 1 mm, 2 mm and 3 mm respectively. The speech material for phonation test consisted of Vowels sounds /a/, /i/, and /o/. Speech analysis to assess phonation was done using digital acoustic analysis (PRAAT software). The obtained results were statistically analyzed by One-way ANOVA and Tukey's multiple post-hoc for comparison of four experimental conditions with respect to different vowel sounds. Mean harmonics to noise ratio (HNR) values obtained for all the Experimental conditions did not show significant difference (p>0.05). In conclusion, an increase in the thickness of the acrylic palatal plate of maxillary prosthesis for about 1 mm - 3mm in complete or partial maxillary removable dentures resulted in no significant effect on phonation of vowel sounds /a/, /i/ and /o/. Increasing the thickness of the palatal plate from 1 mm to 3 mm has not shown any significant effect on the phonation.

  2. Mucous retention cyst of the soft palate: a case presentation.

    PubMed

    Ellis, S G; Lee, N J; Peckitt, N S

    1995-12-01

    This article describes a mucous retention cyst of the soft palate associated with an over-extended complete maxillary denture. The clinical and anatomical relevance of the fovea palatinae are discussed with respect to the posterior palatal seal and post-dam positioning.

  3. Maximum bite force in elderly indigenous and non-indigenous denture wearers.

    PubMed

    Borie, Eduardo; Orsi, Iara A; Fuentes, Ramón; Beltrán, Víctor; Navarro, Pablo; Pareja, Felipe; Raimundo, Lariça B

    2014-01-01

    The aim of this study was to compare the measures of maximum bite force (MBF) in elderly edentulous indigenous (Mapuche) and non-indigenous individuals with new complete dentures at two different measuring times. A sample of 100 elderly subjects was divided into two groups: 50 indigenous and 50 non-indigenous, each including 25 females and 25 males. All individuals were totally edentulous, with new maxillary and mandibular removable complete dentures. Measurements were taken at the time of new prosthesis placement and after 1 month of use. Subjects were asked to perform with maximum effort three bites per side at maximum intercuspidation, with a rest time of 2 minutes in between. Statistics were analyzed with Student 's t-test. The MBF values were significantly higher in indigenous than non-indigenous subjects. Force after 1 month of wearing the new prosthesis was significantly higher than at the time of new prosthesis placement. No significant difference was found between sides. Elderly indigenous complete denture wearers had the greatest MBF values. Denture wearers were observed to undergo an adaptation process to the new prosthesis, with MBF increasing considerably after one month of use.

  4. Resilient Attachments as an Alternative to Conventional Cast Clasp Removable Partial Denture: 3-Year Follow-up.

    PubMed

    Schuh, Cristian; Adiel Skupien, Jovito; Mesko, Mauro Elias; Valentini, Fernanda; Pereira-Cenci, Tatiana; Boscato, Noéli

    2014-12-01

    The present clinical report describes the prosthodontic management for a patient with uncontrolled bleeding and diabetes mellitus treated with a maxillary complete denture and a mandibular partial fixed dental prosthesis designed to interface with a removable cast framework partial denture retained by 2 ERA attachments. This approach was undertaken to improve both retention and stability of the distal extension Kennedy Class I removable partial denture. The rehabilitation provided better anterior esthetics than if treated with a conventional clasp retained removable partial denture, by employing a simple, practical design and offering a significant biomechanical advantages, restoring both oral health and function. Thus, this treatment modality, involving an ERA system and transfixation in fixed crowns, is an effective treatment and can be indicated as a clinical alternative for edentulous and partially edentulous patients with systemic disorders or for patients in economic situations that might preclude implant-based rehabilitation.

  5. Technical Quality of Complete Dentures: Influence on Masticatory Efficiency and Quality of Life.

    PubMed

    Tôrres, Ana Clara Soares Paiva; Maciel, Amanda de Queiroz; de Farias, Danielle Bezerra; de Medeiros, Annie Karoline Bezerra; Vieira, Flávia Patrícia Tavares Veras; Carreiro, Adriana da Fonte Porto

    2017-11-09

    To evaluate the effect of the technical quality of conventional complete dentures (CD) on masticatory efficiency and quality of life (QoL) of denture wearers during a 1-year follow-up. A prospective clinical trial with 32 edentulous patients (mean age of 60.2 years) wearing mandibular and maxillary dentures was conducted. All patients were evaluated wearing their preexisting dentures and after 3, 6, and 12 months postinsertion of new dentures. A reproducible method for objective evaluation of the technical quality of CDs was employed. Masticatory efficiency was evaluated by the colorimetric method using beads as artificial testing food. The oral health impact on patient QoL was measured using the OHIP-EDENT (Oral Health Impact Profile in Edentulous Adults) questionnaire. The nonparametric Wilcoxon test was applied to reveal any differences in technical quality between the preexisting and new dentures. The Friedman test was used to detect differences in masticatory efficiency and oral health impact on QoL. Spearman's correlation was applied to reveal correlation between the variables. Comparing preexisting and new dentures, significant improvement was found in technical quality between the dentures (p < 0.001). There was no statistically significant difference in masticatory efficiency. A significant decrease was found in the total OHIP-EDENT scores after denture replacement. A positive correlation was found between technical quality and OHIP in the new denture wearers (p = 0.011). According to the results of this study, denture quality significantly improved patients' oral health-related QoL; however, insertion of new dentures did not influence masticatory efficiency. © 2017 by the American College of Prosthodontists.

  6. Evaluation of Palatal Plate Thickness of Maxillary Prosthesis on Phonation- A Comparative Clinical Study

    PubMed Central

    B, Sreedevi; Anne, Gopinadh; Manne, Prakash; Bindu O, Swetha Hima; Atla, Jyothi; Deepthi, Sneha; Chaitanya A, Krishna

    2014-01-01

    Background: Prosthodontic treatment involves clinical procedures which influence speech performance directly or indirectly. Prosthetic rehabilitation of missing teeth with partial or complete maxillary removable dentures influences the individual voice characteristics like Phonation, resonance etc. Aim: To evaluate the effect of Acrylic palatal plate thickness (1mm-3mm) of maxillary prosthesis on phonation. Materials and Methods: Twelve subjects were selected randomly between the age group of 20-25 years who have full complement of teeth and have no speech problems. Speech evaluation was done under four experimental conditions i.e. Without any experimental acrylic palatal plate (control), with experimental acrylic palatal plates of thickness 1 mm, 2 mm and 3 mm respectively. The speech material for phonation test consisted of Vowels sounds /a/, /i/, and /o/. Speech analysis to assess phonation was done using digital acoustic analysis (PRAAT software). The obtained results were statistically analyzed by One-way ANOVA and Tukey’s multiple post-hoc for comparison of four experimental conditions with respect to different vowel sounds. Results: Mean harmonics to noise ratio (HNR) values obtained for all the Experimental conditions did not show significant difference (p>0.05). In conclusion, an increase in the thickness of the acrylic palatal plate of maxillary prosthesis for about 1 mm - 3mm in complete or partial maxillary removable dentures resulted in no significant effect on phonation of vowel sounds /a/, /i/ and /o/. Conclusion: Increasing the thickness of the palatal plate from 1 mm to 3 mm has not shown any significant effect on the phonation. PMID:24959508

  7. A 3-year follow-up study of overdentures retained by mini-dental implants.

    PubMed

    Preoteasa, Elena; Imre, Marina; Preoteasa, Christina Teodora

    2014-01-01

    This study evaluated overdentures retained by mini-dental implants (MDIs) as a treatment option for complete edentulism during a 3-year follow-up period. This observational clinical study included completely edentulous patients who were treated with MDI-retained overdentures. The MDIs were supplied by the manufacturer. Twenty-three patients received 7 maxillary and 16 mandibular MDI overdentures retained by 110 MDIs. Of the 36 MDIs placed in the maxilla, 8 failed (in two patients), 2 had compromised survival, 3 displayed satisfactory survival, and 23 were successful. Of the 74 MDIs placed in the mandible, 11 displayed satisfactory survival and 63 were successful. The marginal bone loss was more pronounced for the MDIs placed mesially (intercalated), in areas of decreased ridge width and bone density, and with lower values of insertion torque. The overdentures fractured in seven patients; in 4 of them, this corresponded to the implant housing area. Self-reported reasons for patient dissatisfaction included occasional pain under the overdenture (n = 5) and instability of the maxillary antagonist complete denture (n = 4). Based on this research, considering its limitations, it is possible to conclude that survival rates and health status are better for MDI overdentures applied in the mandible than for those applied in the maxilla. The most severe prosthetic complications encountered were overdenture base fracture, matrix detachment, and instability of the maxillary antagonist denture.

  8. Study on digital teeth selection and virtual teeth arrangement for complete denture.

    PubMed

    Yu, Xiaoling; Cheng, Xiaosheng; Dai, Ning; Chen, Hu; Yu, Changjiang; Sun, Yuchun

    2018-03-01

    In dentistry, the complete denture is a conventional treatment for edentulous patients. The computer-aided design and computer-aided manufacturing (CAD/CAM) has been applied on the digital complete denture which is developed rapidly. Tooth selection and arrangement is one of the most important parts in digital complete denture. In this paper, we propose a new method of personalized teeth arrangement. This paper presents a method of arranging teeth virtually for a complete denture. First, scan and extract the feature points of the 3D triangular mesh data of artificial teeth (PLY format), then establish a tooth selection system. Second, scan and mark the anatomic characteristics of the maxillary and mandibular cast surfaces, such as facial midline, the curve of the arches. With the enter information, the study calculates the common arrangement lines of artificial teeth. Third, select the preferred artificial teeth and automatically arrange them virtually in the correct position by using our own software. After that, design the gingival part of the dentures on the basic of the arranged teeth on the screen and then fabricated it by using Computerized Numerical Control (CNC) technology, Rapid Prototyping (RP) technology or 3D printer technology. Finally, select artificial teeth were embedded in wax rims. This system can choose artificial teeth reasonably and the teeth placement can meet the dentist's request to a certain extent, whereas all the operations are based on the medical principles. The study performed here involves computer sciences, medicine, and dentistry, a teeth selection system was proposed and virtual teeth arrangement was described. This study has the capacity of helping operators to select teeth, which improved the accuracy of tooth arrangement, and customized complete denture. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Finite element analysis and clinical complications in mandibular implant-overdentures opposing maxillary dentures.

    PubMed

    Khuder, Tameem; Yunus, Norsiah; Sulaiman, Eshamsul; Dabbagh, Ali

    2017-11-01

    Denture fracture is a common clinical complication caused by improper material selection, design, or fabrication technique. This study aimed to investigate the effect of two attachment systems on fracture risk of the implant-overdentures (IOD) via finite element analysis (FEA), using the force distributions obtained from patients' occlusal analyses and to compare the obtained results with the clinical complications associated with these attachments. A three-dimensional jaw model comprised of the edentulous bones was constructed. Three types of mandibular prostheses including complete denture (CD) (model LCD), IOD with Locator attachment (model LID-L), and IOD with telescopic attachment (model LID-T), as well as a maxillary CD (model UCD) were assembled. The vertical occlusal forces at anterior and posterior quadrants were obtained from the patients wearing mandibular CDs or IODs. The FEA results were further compared with the mechanical failures of different prostheses observed at patient recalls. In overall, the fracture risk of mandibular prostheses was lower than the maxillary compartments. The UCD opposing LCD underwent higher strains than that opposing LID-L and LID-T, which was mostly concentrated at the anterior mid-palatal polished surface. On the other hand, LID-L showed the lowest strain, followed by LID-T, and LCD. The obtained results were consistent with the clinical complications observed in the patient recalls. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Lenticular card: a new method for denture identification.

    PubMed

    Colvenkar, Shreya S

    2010-01-01

    The need for denture marking is important for forensic and social reasons in case patients need to be identified individually. Majority of the surface marking and inclusion techniques are expensive, time consuming, and do not permit the incorporation of large amounts of information. In this article, the method to include a lenticular identification card stood out from the currently available denture marking methods in various ways. The lenticular card stores the patient's information has two or more images that can be viewed by changing the angle of view. The maxillary denture was processed according to the manufacturer's instructions. The lenticular identification card was incorporated in the external posterior buccal surface of the maxillary denture using salt and pepper technique. For testing of durability, denture with the identifier was placed in water for up to 4 months. The proposed method is simple, cheap, and can store a large amount of information, thus allowing quick identification of the denture wearer. The labels showed no sign of fading or deterioration.

  11. Zygomatic implant-retained fixed complete denture for an elderly patient.

    PubMed

    Baig, Mirza Rustum; Rajan, Gunaseelan; Yunus, Norsiah

    2012-06-01

    Dental rehabilitation of a completely edentulous geriatric patient has always been a challenge to the clinician, especially in treating those with higher expectations and demands. Treatment duration and the amount of residual alveolar bone available are often important considerations when planning for dental implant-based fixed treatment for these patients. With the introduction of zygomatic implants, a graftless alternative solution has emerged for deficient maxillary bone with provision for immediate loading. This article describes the treatment of a completely edentulous elderly patient using zygomatic implants in conjunction with conventional implants. The implants were immediately loaded using a definitive acrylic resin fixed denture reinforced with a cast metal framework, to provide function and aesthetics. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  12. Effect of palatal form on movement of teeth during processing of complete denture prosthesis: An in-vitro study.

    PubMed

    Babu, Sumanth; Manjunath, Shaurya; Vajawat, Mayuri

    2016-01-01

    The aim of this in-vitro study was to assess the influence of shallow and deep palatal forms on the movement of teeth during the processing of complete denture prosthesis. Maxillary casts with shallow and deep palatal forms were selected and duplicated to make 10 casts of each palatal form. Base plates were constructed and teeth were arranged in their anatomic positions. Metal pins with true apex were placed on the central groove of the right and left first molars and one on the incisive papilla area as a reference point. Casts were scanned using i-CAT Vision Q 1.9 (i-CAT cone beam 3D dental imaging system by Imaging Sciences International, PA, USA), which has 360° rotational tomography. The distances between the apices of metallic pin inserts on the teeth and fitted point of reference were recorded in buccopalatal axes at waxed up stage, after deflasking, and after finishing and polishing. Results showed a statistically significant movement of teeth in shallow and deep palatal forms during all stages of complete denture processing. In shallow palatal form dentures, there was a significant tooth movement in palatal direction between Stages 1 and 2 (P ≤ 0.05) and buccal movement between Stages 2 and 3. In deep palatal form dentures, teeth showed a statistically significant (P ≤ 0.05) movement in buccal direction during all stages of denture processing. Teeth showed significant movement during processing of acrylic resin dentures. Overall, the movement of teeth in shallow palatal form dentures was in palatal direction, whereas in deep palatal form dentures, the movement of teeth was in buccal direction.

  13. Antimicrobial activity of denture adhesive associated with Equisetum giganteum- and Punica granatum-enriched fractions against Candida albicans biofilms on acrylic resin surfaces.

    PubMed

    Almeida, Nara Ligia Martins; Saldanha, Luiz Leonardo; da Silva, Rafaela Alves; Pinke, Karen Henriette; da Costa, Eliane Ferraz; Porto, Vinicius Carvalho; Dokkedal, Anne Lígia; Lara, Vanessa Soares

    2018-01-01

    Candida biofilms adhere to the internal surface of removable dentures, which is an etiological factor in the pathogenesis of denture stomatitis (DS). Adhesive materials are used at the base of maxillary complete dentures to improve their retention and chewing qualities. This article reports the antimicrobial activity of the enriched fractions of Equisetum giganteum and Punica granatum incorporated into a denture adhesive against C. albicans biofilm. The biofilms were induced on the surface of heat-cured acrylic resin specimens that were previously treated with a mixture of adhesive/herb extracts. The antimicrobial activity was evaluated by CFU counts, XTT reduction, and SEM and CLSM analysis. Both herb extracts amplified the anti-biofilm action of the adhesive on the acrylic resin by up to 12 h. Therefore, when these extracts were combined with COREGA®, they played a collaborative and innovative role in biofilm control and can be considered alternatives for temporary use in the treatment and/or prevention of DS.

  14. Influence of reinforcement on strains within maxillary implant overdentures.

    PubMed

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    2015-01-01

    The purpose of this study was to examine the influence of reinforcement of an embedded cast on the strains within maxillary implant overdentures. A maxillary edentulous model with implants placed bilaterally in the canine positions, dome-shaped copings, and experimental overdentures was fabricated. Rosette-type strain gauges were attached in the canine positions and at three points along the midline of the polished surface of the denture and connected to the sensor interface controlled by a personal computer. Experimental dentures with five different reinforcements were tested: without reinforcement; with a cast cobalt-chrome reinforcement over the residual ridge and the tops of the copings; with the same reinforcement from first molar to first molar, over the residual ridge and the tops of the copings; with the same reinforcement over the residual ridge and the sides of the copings; and with the same reinforcement from first molar to first molar, over the residual ridge and the sides of the copings. A vertical occlusal load of 49 N was applied to the first premolar and then to the first molar, and the strains were measured and compared by analysis of variance. In both loading situations, significantly less strain was recorded in dentures with reinforcement than in those without reinforcement. When the first premolar was loaded on dentures with and without palatal reinforcement at the first premolars, the strains on the denture with reinforcement over the tops of the copings were significantly lower than on the denture with reinforcement over the sides of the copings at the canine position. Cast reinforcement over the residual ridge and the top of copings embedded in an acrylic base reduced the strain from occlusal stress on maxillary implant overdentures.

  15. Reinforcing effect of glass-fiber mesh on complete dentures in a test model with a simulated oral mucosa.

    PubMed

    Yu, Sang-Hui; Oh, Seunghan; Cho, Hye-Won; Bae, Ji-Myung

    2017-11-01

    Studies that evaluated the strength of complete dentures reinforced with glass-fiber mesh or metal mesh on a cast with a simulated oral mucosa are lacking. The purpose of this in vitro study was to compare the mechanical properties of maxillary complete dentures reinforced with glass-fiber mesh with those of metal mesh in a new test model, using a simulated oral mucosa. Complete dentures reinforced with 2 types of glass-fiber mesh, SES mesh (SES) and glass cloth (GC) and metal mesh (metal) were fabricated. Complete dentures without any reinforcement were prepared as a control (n=10). The complete dentures were located on a cast with a simulated oral mucosa, and a load was applied on the posterior artificial teeth bilaterally. The fracture load, elastic modulus, and toughness of a complete denture were measured using a universal testing machine at a crosshead speed of 5 mm/min. The fracture load and elastic modulus were analyzed using 1-way analysis of variance, and the toughness was analyzed with the Kruskal-Wallis test (α=.05). The Tukey multiple range test was used as a post hoc test. The fracture load and toughness of the SES group was significantly higher than that of the metal and control groups (P<.05) but not significantly different from that of the GC group. The elastic modulus of the metal group was significantly higher than that of the control group (P<.05), and no significant differences were observed in the SES and GC groups. Compared with the control group, the fracture load and toughness of the SES and GC groups were higher, while those of the metal group were not significantly different. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. Development of chair-side evaluation system of swallowing discomfort of denture wearers

    NASA Astrophysics Data System (ADS)

    Matsumoto, Keisuke; Ikuta, Ryuhei; Kataoka, Kanako; Ono, Yumie; Tamaki, Katsushi

    2018-02-01

    We investigated the appropriate hemodynamic parameters of functional near-infrared spectroscopy (fNIRS) to best differentiate the discomfort intensity related to swallowing in healthy subjects wearing different types of simulated dentures. Thirty-one subjects performed 4 sessions of water-swallowing task in a sitting position without or with wearing any one of the 3 simulated dentures under continuous fNIRS monitoring of the prefrontal cortex. The simulated dentures were consisted of a flat maxillary palatal bar and bilateral support attachment to the teeth and gum. The palatal bar positions were arranged along with the anterior, middle, or posterior areas of the upper jaw. The cumulative values of oxyhemoglobin and deoxyhemoglobin concentration changes were calculated for periods of 5 - 10 s from completion of swallowing. Subjective rating of swallowing-discomfort was the lowest without wearing denture and increased along with the palatal bar position placed from anterior to posterior. Cumulated deoxyhemoglobin signals calculated for 10 s post-swallowing event in the left frontopolar prefrontal cortex showed the best correlation with the subjective rating of discomfort in swallowing with dentures. These neurological signatures would be beneficial to detect swallowing discomfort in elderly denture wearers who have difficulty in communicating with dentists.

  17. Antimicrobial activity of complete denture cleanser solutions based on sodium hypochlorite and Ricinus communis - a randomized clinical study.

    PubMed

    Salles, Marcela Moreira; Badaró, Maurício Malheiros; Arruda, Carolina Noronha Ferraz de; Leite, Vanessa Maria Fagundes; Silva, Cláudia Helena Lovato da; Watanabe, Evandro; Oliveira, Viviane de Cássia; Paranhos, Helena de Freitas Oliveira

    2015-01-01

    To preserve oral health and to maintain the prosthetic devices, it is important not only to improve the properties of commonly known hygiene products, but also to investigate new materials with antimicrobial action. Objectives This study evaluated the antimicrobial activity of sodium hypochlorite (0.25% and 0.50%) and 10% Ricinus communis' solutions against specific microorganisms. Sixty four maxillary complete denture wearers were instructed to brush their dentures three times a day and to soak them (20 min/day) in the solutions: SH1: 0.25% sodium hypochlorite; SH2: 0.5% sodium hypochlorite; RC: 10% R. communis oil; and C: 0.85% saline (control). The solutions were used for 7 days in a randomized sequence. Following each period of use, there was a 1-week washout period. Antimicrobial activity was determined by Colony Forming Units (CFU) counts of Streptococcus mutans, Candida spp., and gram-negative microorganisms. For collecting biofilm, the internal surface of maxillary dentures was brushed with saline solution, and biofilm suspension obtained. After dilutions (100 - 10-3), aliquots were seeded in Mitis salivarius, CHROMagar Candida, and MacConkey agar for detecting S. mutans, Candida spp., or gram-negative microorganisms, respectively. After incubation, colonies were counted, and CFU/mL values were calculated. Then, transformation - log10 (CFU+1) - data were analyzed using the Friedman test (α=0.05). Results showed significant differences between the solutions (p<0.001). All three solutions showed antimicrobial activity against S. mutans. Against Candida spp., RC and SH1 solutions showed similar effect while SH2 showed superior activity. SH1 and SH2 solutions showed antimicrobial action against gram-negative microorganisms. The Candida species most frequently isolated was C. albicans, followed by C. tropicalis and C. glabrata. The 0.5% sodium hypochlorite solution was the most effective and might be used to control denture biofilm. C. albicans was the most frequently isolated Candida sp.

  18. Perception of Esthetic Impact of Smile Line in Complete Denture Wearers by Different Age Groups.

    PubMed

    Pithon, Matheus Melo; Alves, Leandro Pereira; da Costa Prado, Matheus; Oliveira, Rener Leal; Costa, Matheus Souza Campos; da Silva Coqueiro, Raildo; Gusmão, João Milton Rocha; Santos, Rogério Lacerda

    2016-10-01

    To evaluate esthetic perceptions based on tooth exposure when smiling of patients wearing complete dentures by evaluators in different age groups. Alterations were made to a front view photograph of a smiling patient wearing complete maxillary and mandibular dentures. Alterations in the smile line were simulated to increase or decrease tooth exposure (increments of 0.5 mm). For this purpose, image manipulation software was used. After manipulation, images were printed on photo paper, attached to a questionnaire, and distributed to individuals in three age groups (n = 150). To evaluate the esthetic perception for each image, a visual analog scale was used, with 0 representing least attractive, 5 representing attractive, and 10 representing very attractive. Differences between examiners were analyzed using the Mann-Whitney test. All statistical analyses were performed with a degree of confidence of 95%. Two evaluators did not observe any differences between images. The images given the best and worst scores were E and O (alterations of 2 and 7 mm), respectively, in the 15- to 19-year-old group, B and O (alterations of 0.5 and 7 mm), respectively, in the 35- to 44-year-old group, and A and M (no alteration and 6 mm alteration), respectively, in the 65- to 74-year-old group. When the images were presented together (images 1 and 2), the unaltered image was selected by individuals of different age groups as the best, and the image with a change of 7 mm was selected as the worst. In this study, complete dental prostheses with smile lines that coincided with the cervical margins of the anterior teeth were the most acceptable. Less exposure of the maxillary teeth when smiling corresponded with decreased attractiveness. © 2015 by the American College of Prosthodontists.

  19. Palateless custom bar supported overdenture: a treatment modality to treat patient with severe gag reflex.

    PubMed

    Singh, Kunwarjeet; Gupta, Nidhi

    2012-01-01

    To suggest a custom bar supported overdenture treatment modality for prosthodontic management of patients with severe gag reflex. Some patients have a severe gag reflex and cannot tolerate conventional maxillary complete dentures with maximum palatal coverage and extensions of all borders. The condition further gets complicated in patients suffering from respiratory problems along with severe gag reflex. Severe gagging acts as a barrier to treat such patients with accepted clinical procedures and prevent patients from wearing the prosthesis. By saving some of the remaining natural teeth and fabricating, a horse shoe shape palateless simple tooth or bar supported overdenture can be successfully used for treating such patients. The remaining maxillary right and left canines were prepared with the tapered round end diamond bur to receive copings of custom bar after intentional root canal treatment of same teeth. Impression was made with light body and putty of the polyvinyl siloxane elastomer with double step putty wash technique. Impression was poured with die stone. Wax pattern of copings with bar was fabricated with inlay wax which was invested and casted. After retrieving the bar, it was finished and its fit was evaluated. The coping-bar assembly was finally cemented with the glass ionomer cement. Palateless overdenture was fabricated by conventional technique used for the fabrication of complete denture. Palateless custom bar supported overdenture procedure can be successfully used for the management of patients with severe gag reflex with improved denture retention, stability, chewing efficiency and comfort of the patient.

  20. Effect of mini-implant-supported mandibular overdentures on electromyographic activity of the masseter muscle during chewing of hard and soft food.

    PubMed

    Ashmawy, Tarek Mohy; El Talawy, Dina Bahgat; Shaheen, Nasser Hussein

    2014-09-01

    To objectively evaluate the effect of mini-implant- supported mandibular overdentures on electromyographic activity (EMG) of the masseter muscle during chewing of hard and soft foods. Twelve completely edentulous patients (4 females and 8 males) with maladaptive experience of wearing mandibular dentures received new maxillary and mandibular dentures. After 3 months of adaptation, four mini dental implants (MDIs) were inserted in the interforaminal region of the mandible, and the new mandibular dentures were connected to the implants immediately with O/ring attachments. The activity of masseter muscle (EMG) and the duration of chewing cycle were measured during chewing hard (carrot) and soft (gum) foods. The measurements were made 3 months after wearing each of the following prostheses: the new conventional dentures; and the MDI-retained mandibular overdentures. The EMG of masseter muscle increased and the DC decreased with MDI-retained mandibular overdentures when compared to conventional dentures. Hard food (carrot) was associated with increased EMG and decreased DC when compared to soft food (gum) for both conventional dentures and MDI-retained mandibular overdentures. Mini-implant-supported mandibular overdentures are associated with increased activity of masseter muscle and decreased duration of chewing cycle for both hard and soft foods when compared to conventional dentures.

  1. Microwave disinfection of maxillary and mandibular denture bases contaminated with Candida Albican.

    PubMed

    Bamigboye, S A; Dosumu, O O; Ajayi, D M

    2015-09-01

    Oral environment is not sterile, and dentures worn by the patients can be infected and therefore needs disinfection. Solution disinfectants such as sodium hypochlorite and glutaraldehyde can be used but they have side effects. Microwave disinfection method is more recent, however, there are conflicting reports at the moment on the appropriate power and time regimen for disinfection of denture. To determine the power and time regimen at which the disinfection of dentures can be achieved using microwave. Forty-five acrylic denture bases were fabricated for each of the jaws and infected with solution of a stock Candida albicans and 30 infected bases were employed as control. These were placed in normal saline and then subjected to different microwave power and time regimen. Aliquots from these post-microwave solution were titrated against sabauraud agar which was subsequently incubated at 37 degrees C for 48 hours. The agar were examined for candida growth. The denture bases subjected to microwave disinfection at 350W showed Candida growth after microwave treatment irrespective of the time employed. Conversely, those microwaved at 650W and 690W for four and six minutes showed no microbial growth. The microwave regimen of 650W at 4 and 6 minutes completely disinfected the denture bases. Disinfection at higher microwave energy should be done with caution as distortion of the denture may occur.

  2. Food selection and perceptions of chewing ability following provision of implant and conventional prostheses in complete denture wearers.

    PubMed

    Allen, Finbarr; McMillan, Anne

    2002-06-01

    The loss of natural teeth compromises chewing efficiency, and edentulous patients often have a diet that is deficient in fibre and vitamins. Prostheses that are retained on implants offer the possibility of overcoming some of the limitations of conventional dentures in terms of chewing efficiency. The aim of this study was to test the hypothesis that improvement in satisfaction with oral prostheses would result in improved food selection in edentulous patients. This prospective study involved three groups, namely (i) subjects who requested and received implants to stabilise a complete fixed or removable prosthesis (IG, n = 26), (ii) edentulous subjects who requested implant prostheses, but received conventional dentures (CDG1, n = 22), and (iii) edentulous subjects who requested and received conventional dentures (CDG2, n = 35). Data were collected using validated questionnaires pre- and postoperatively. Prior to treatment, all subjects were asked whether they ate a variety of hard and soft foods, to indicate the degree of difficulty they experienced when chewing these foods, and to rate their satisfaction with various aspects of their maxillary and mandibular complete dentures. Following the completion of treatment, subjects completed the questionnaires again. Pre- and postoperative data were compared. Subjects who received implant prostheses reported significant improvement in chewing hard and soft foods. CDG2 subjects also reported improvement, but CDG1 subjects reported no change or even deterioration following treatment. Despite reported improvement in satisfaction with comfort and ability to chew food, 30-50% of IG and CDG2 subjects still avoided eating foods such as carrot and apple. This suggests that, in the absence of tailored dietary advice, apparently successful prosthetic rehabilitation does not necessarily result in a satisfactory diet.

  3. Patient satisfaction and dissatisfaction with mandibular two-implant overdentures using different attachment systems: 5-year outcomes.

    PubMed

    Al-Zubeidi, Mohammed I; Alsabeeha, Nabeel H M; Thomson, W Murray; Payne, Alan G T

    2012-10-01

    Different attachment systems for mandibular two-implant overdentures could influence levels of patient satisfaction. Positive consensus of the majority of patients being satisfied does not preclude the possibility of dissatisfaction for some. To evaluate patient satisfaction and dissatisfaction before and after 5 years of wearing mandibular two implant overdentures using different attachment systems ; to determine the prognostic relevance of pretreatment complete denture complaints to treatment outcomes. A total of 106 edentulous participants enrolled in a clinical trial completed a preliminary self-report inventory of their original complete denture complaints.New complete maxillary dentures and mandibular two-implant overdentures were provided to each participant using one of six different attachment systems. Patient satisfaction was determined at pretreatment; at baseline with mandibular two-implant overdenture insertion; and then annually for 5 years, using visual analogue and Likert-type scales. Patient satisfaction with mandibular two-implant overdentures showed significant changes pre- to posttreatment(baseline) in all domains, but these were significant immediately and maintained without further significance for 5 years, other than pain with the overdenture. After 5 years, no significant differences were observed with all the attachment systems. Highly significant differences were found with some social and psychological aspects by the fifth year compared to baseline. Diagnostic and prognostic indicators from a pretreatment inventory identified 12 participants (13.5%) who were dissatisfied. These indicators revealed a maladaptive predisposition to mandibular two-implant overdentures. The provision of mandibular two-implant overdentures will, in the majority of patients, significantly enhance levels of patient satisfaction for 5 years, as compared to complete mandibular dentures, regardless of the attachment system. Careful evaluation of pretreatment complaints with conventional dentures can possibly identify patient dissatisfaction with mandibular two-implant overdentures [corrected]. © 2010 Wiley Periodicals, Inc.

  4. Maxillary rehabilitation using a removable partial denture with attachments in a cleft lip and palate patient: a clinical report.

    PubMed

    Palmeiro, Marina Rechden Lobato; Piffer, Caroline Scheeren; Brunetto, Vivian Martins; Maccari, Paulo César; Shinkai, Rosemary Sadami Arai

    2015-04-01

    Clefts of the lip and/or palate (CLP) are oral-facial defects that affect health and overall quality of life. CLP patients often need multidisciplinary treatment to restore oral function and esthetics. This paper describes the oral rehabilitation of a CLP adult patient who had maxillary bone and tooth loss, resulting in decreased occlusal vertical dimension. Functional and cosmetic rehabilitation was achieved using a maxillary removable partial denture (RPD) attached to telescopic crowns. Attachment-retained RPDs may be a cost-effective alternative for oral rehabilitation in challenging cases with substantial loss of oral tissues, especially when treatment with fixed dental prostheses and/or dental implants is not possible. © 2014 by the American College of Prosthodontists.

  5. Biometric ratio in estimating widths of maxillary anterior teeth derived after correlating anthropometric measurements with dental measurements.

    PubMed

    Kini, Ashwini Y; Angadi, Gangadhar S

    2013-06-01

    To correlate dental measurements i.e. combined mesiodistal width of six maxillary anterior teeth with facial measurements i.e. inner canthal distance, interpupillary distance and intercommissural width and acquire a biometric ratio to serve as a preliminary guide in selection of the maxillary anterior teeth. In the absence of pre-extraction records, the resultant denture can lead to patient dissatisfaction towards the aesthetic appeal of their dentures. The maxillary anterior teeth play a pivotal role in denture aesthetics. Various techniques and biometric ratios have been described in literature for selection of the maxillary anteriors. This study derives a biometric ratio for the same, obtained after correlating anthropometric measurements with dental measurements. Two standardized digital photographs of the face were generated; one, when the facial muscles were relaxed and the other, when the subject was smiling; thereby, revealing the maxillary anterior teeth upto the canine tip. Inner canthal distance, interpupillary distance, intercommissural distance, distance between the tips of the maxillary canines and distance between the distal surfaces of the canines were measured. On the cast, the distance between tips of maxillary canines and distance between distal surfaces of maxillary canines were noted. The data was analysed using Spearman's rank correlation coefficient. A high correlation was found between the intercommissural measurement with distance between the tips of the canines on the photograph and between the tips of the canines on the cast with the interpupillary distance, giving a biometric ratio of 1:1.35 and 1:1.41 respectively. The least correlation was between the inner canthal distance and the tips of the canines measured on the photograph. Extra oral anthropometric measurements of the interpupillary distances and the intercommissural distances with the help of standardised photographs can help us determine the combined widths of the anterior teeth accurately, thus aiding their selection in the absence of pre-extraction records. © 2012 John Wiley & Sons A/S and The Gerodontology Society. Published by John Wiley & Sons Ltd.

  6. Multidisciplinary approach to restoring anterior maxillary partial edentulous area using an IPS Empress 2 fixed partial denture: a clinical report.

    PubMed

    Dundar, Mine; Gungor, M Ali; Cal, Ebru

    2003-04-01

    Esthetics is a major concern during restoration of anterior partial edentulous areas. All-ceramic fixed partial dentures may provide better esthetics and biocompatibility in the restoration of anterior teeth. This clinic report describes a multidisciplinary approach and treatment procedures with an IPS Empress 2 fixed partial denture to restore missing anterior teeth.

  7. Comparative evaluation of pressure generated on a simulated maxillary oral analog by impression materials in custom trays of different spacer designs: An in vitro study.

    PubMed

    Chopra, Sakshi; Gupta, Narendra Kumar; Tandan, Amrit; Dwivedi, Ravi; Gupta, Swati; Agarwal, Garima

    2016-01-01

    Literature reveals that masticatory load on denture bearing tissues through complete dentures should be maximum on primary stress bearing areas and least on relief area in accordance with the histology of underlying tissues. A study to validate the existing beliefs was planned to compare the pressure on mucosa using selective pressure technique and minimal pressure technique, with the incorporation of two different impression materials utilizing the pressure sensors during secondary impression procedure. The study was performed using a maxillary analog. Three pressure sensors were imbedded in the oral analog, one in the mid palatine area and the other two in the right and left ridge crest. Custom trays of two different configurations were fabricated. The two impression materials tested were light body and zinc oxide eugenol. A total of 40 impressions were made. A constant weight of 1 kg was placed, and the pressure was recorded as initial and end pressures. A significant difference in the pressure produced using different impression materials was found (P < 0.001). Light body vinyl polysiloxane produced significantly lesser pressure than zinc oxide eugenol impression materials. The presence of relief did affect the magnitude of pressure at various locations. All impression materials produced pressure during maxillary edentulous impression making. Tray modification is an important factor in changing the amount of pressure produced. The impression materials used also had a significant role to play on the pressures acting on the tissues during impression procedure. Light body VPS impression material may be recommended to achieve minimal pressure on the denture bearing tissues in both selective as well as minimal pressure techniques.

  8. Implant overdentures: dental students' performance in fabrication, denture quality, and patient satisfaction.

    PubMed

    Aragon, Cecilia E; Cornacchio, Angelica Lee Petrina; Ibarra, Lilia Marcela; Saad, Muhammed N; Zibrowski, Elaine

    2010-09-01

    The purpose of this study was to evaluate dental students' performance when fabricating a mandibular two-implant overdenture (OD) as compared to conventional dentures (CD) and to determine if these prostheses were successful. Twenty students and twenty patients were divided into two groups: complete denture group (CDG) and maxillary denture and two-implant OD group (ODG). Students' progress was evaluated at each appointment as they were given a clinical assessment score (CAS), which varied from 1 (unacceptable, needs to repeat procedure) to 4 (acceptable, no errors). The success of the prosthesis was evaluated by the patients using a visual analog scale (VAS) and an expert (a prosthodontist) using a denture quality assessment (DQA) form. Performance for both groups was not statistically different across all eight appointments (CDG 3.16 versus ODG 3.25; p=0.46). Patients with ODs reported greater stability with their dentures (p=0.048) and greater ability to chew than patients with CDs (p=0.03). There were no differences between the groups in terms of expert appraisal (ODG 71.1 versus CDG 67.5; p=0.59). The performance of dental students when fabricating a two-implant OD is thus not different from that of a CD. Students can successfully fabricate a two-implant OD as perceived by both patients and prosthodontists.

  9. Inflammatory fibrous hyperplasia treated with a modified vestibuloplasty: a case report.

    PubMed

    Jaimes, Miguel; Muñante, Jose; Olate, Sergio; Rodriguez-Chessa, Jaime Giuseppe; de Albergaria-Barbosa, Jose Ricardo; Mazzonetto, Renato; Klüppel, Leandro Eduardo

    2008-03-01

    The purpose of this report is to present a case of surgical and prosthetic treatment of a woman with inflammatory fibrous hyperplasia (IFH) and her evaluation during a six month period. IFH is a benign pathology, prevalent in female patients, and principally associated with ill-fitting prosthetic devices in need of adjustment. It is common for patients to require surgical removal of the hyperplastic tissue and fabrication of a new prosthesis. A 55-year-old female with a history of smoking presented with a chief complaint of missing the scheduled adjustment of her maxillary complete denture and the presence of moveable tissue under the denture. Surgical excision of the hyperplastic tissue followed with fixation of the prosthesis for six months to guide the healing of the soft tissue and to reshape the contours of the maxillary supporting tissues. Surgical removal of hyperplasic soft tissue is a routine procedure, and the fixation of the prosthesis for the support of tissue during healing improves intraoral conditions for the fabrication of a new prosthesis in the future.

  10. Spectral analysis of /s/ sound with changing angulation of the maxillary central incisors.

    PubMed

    Runte, Christoph; Tawana, Djafar; Dirksen, Dieter; Runte, Bettina; Lamprecht-Dinnesen, Antoinette; Bollmann, Friedhelm; Seifert, Eberhard; Danesh, Gholamreza

    2002-01-01

    The aim of the study was to measure the influence of the maxillary central incisors free from adaptation phenomena using spectral analysis. The maxillary dentures of 18 subjects were duplicated. The central incisors were fixed in a pivoting appliance so that their position could be changed from labial to palatal direction. A mechanical push/pull cable enabled the incisor section to be handled extraorally. Connected to the control was a sound generator producing a sinus wave whose frequency was related to the central incisor angulation. This acoustic signal was recorded on one channel of a digital tape recorder. After calibration of the unit, the denture duplicate was inserted into the subject's mouth, and the signal of the /s/ sounds subsequently produced by the subject was recorded on the second channel during alteration of the inclination angle simultaneously with the generator signal. Spectral analysis was performed using a Kay Speech-Lab 4300B. Labial displacement in particular produced significant changes in spectral characteristics, with the lower boundary frequency of the /s/ sound being raised and the upper boundary frequency being reduced. Maxillary incisor position influences /s/ sound production. Displacement of the maxillary incisors must be considered a cause of immediate changes in /s/ sound distortion. Therefore, denture teeth should be placed in the original tooth position as accurately as possible. Our results also indicate that neuromuscular reactions are more important for initial speech sound distortions than are aerodynamic changes in the anterior speech sound-producing areas.

  11. Occlusal plane location in edentulous patients: a review.

    PubMed

    Shetty, Sanath; Zargar, Nazia Majeed; Shenoy, Kamalakanth; Rekha, V

    2013-09-01

    Occlusal plane orientation is an important factor in the construction of a complete denture. Occlusal plane could be oriented using landmarks in the mandibular arch as well as in the maxillary arch. In the mandibular arch there are few landmarks which could be used to orient the occlusal plane like the retromolar pad, corner of the lips (lower lip length) whereas the maxillary arch has a number of landmarks, of which the ala-tragal line is the most commonly used and the same being the most controversial. In the following article different landmarks and its accuracy for orientating the occlusal plane in an edentulous subject as studied by various authors has been discussed.

  12. Digital impression and jaw relation record for the fabrication of CAD/CAM custom tray.

    PubMed

    Kanazawa, Manabu; Iwaki, Maiko; Arakida, Toshio; Minakuchi, Shunsuke

    2018-03-16

    This article describes the protocol of a digital impression technique to make an impression and recording of the jaw relationship of edentulous patients for the fabrication of CAD/CAM custom tray using computer-aided design and manufacturing (CAD/CAM) technology. Scan the maxillary and mandibular edentulous jaws using an intraoral scanner. Scan the silicone jig with the maxillary and mandibular jaws while keeping the jig between the jaws. Import the standard tessellation language data of the maxillary and mandibular jaws and jig to make a jaw relation record and fabricate custom trays (CAD/CAM trays) using a rapid prototyping system. Make a definitive impression of the maxillary and mandibular jaws using the CAD/CAM trays. Digitalization of the complete denture fabrication process can simplify the complicated treatment and laboratory process of conventional methods In addition, the proposed method enables quality control regardless of the operator's experience and technique. Copyright © 2018. Published by Elsevier Ltd.

  13. Contribution of the palate to denture base support: an in vivo study.

    PubMed

    Ando, Takanori; Maeda, Yoshinobu; Wada, Masahiro; Gonda, Tomoya

    2014-01-01

    The aim of this study was to examine the contribution of the palate to denture base support. Four subjects with tooth- or implant-supported maxillary overdentures were enrolled. Recordings (strain values converted to load values) were performed using miniature strain gauges and force transducers for the following conditions: metal framework only (A), denture base with full palatal coverage (B), and denture base without palatal coverage (C). The palatal-supporting ratio (PSR) was calculated using the equation PSR = (B - C) / A. The PSR values were less than 10% in all subjects, suggesting that the palate plays a minimal role in denture base support.

  14. Prosthetic aspects and patient satisfaction with resilient liner and clip attachments for bar- and implant-retained mandibular overdentures: a 3-year randomized clinical study.

    PubMed

    ELsyad, Moustafa Abdou

    2012-01-01

    This report aimed to compare prosthetic aspects and patient satisfaction during a 3-year randomized clinical trial of bar- and implant-retained mandibular overdentures attached with either resilient liners or clips. Thirty edentulous male patients (mean age: 62.5 years) received two implants in the anterior mandible after being allocated into two equal groups (according to attachment type received) using balanced randomization. After 3 months, implants were connected with resilient bars. New maxillary complete dentures were then constructed, and mandibular overdentures were retained to the bars with either clips (group I) or silicone resilient liners (group II). Subjects indicated satisfaction with their prostheses using a questionnaire and visual analog scale. Patient satisfaction and prosthetic complications were recorded for both attachments at 6 months and 1 and 3 years after overdenture insertion. Comfort and stability with the maxillary denture and ease of hygiene procedures were rated higher in group II, while ease of handling the dentures was rated higher in group I. No significant differences in other parameters of patient satisfaction between groups were noted after 3 years. The mean number of prosthetic adjustments and repairs in group I (11.9) was significantly higher (P = .00) compared to that in group II (4.8). The most common complication in group I was clip wear, while separation of the resilient liner from the denture base was the most common problem in group II. Hyperplasia under the bar and flabby ridge in the maxilla occurred significantly more often in group I compared to group II. Resilient liner-retained mandibular overdentures had comparable patient satisfaction, less prosthetic maintenance and costs, and less soft tissue complications when compared to clip-retained ones after 3 years.

  15. Effectiveness of Photodynamic Therapy for the Inactivation of Candida spp. on Dentures: In Vitro Study

    PubMed Central

    Mima, Ewerton Garcia de Oliveira; Ribeiro, Daniela Garcia; Dovigo, Livia Nordi; Vergani, Carlos Eduardo; Bagnato, Vanderlei Salvador

    2011-01-01

    Abstract Objective: This in vitro study evaluated the effectiveness of photodynamic therapy (PDT) for the inactivation of different species of Candida on maxillary complete dentures. Background data: The treatment of denture stomatitis requires the inactivation of Candida spp. on dentures. PDT has been reported as an effective method for Candida inactivation. Methods: Reference strains of C. albicans, C. glabrata, C. tropicalis, C. dubliniensis and C. krusei were tested. Thirty-four dentures were fabricated in a standardized procedure and subjected to ethylene oxide sterilization. The dentures were individually inoculated with one of the strains and incubated at 37°C for 24 h. Dentures submitted to PDT (P+L+) were individually sprayed with 50 mg/L of Photogem® (PS) and, after 30 min, illuminated by LED light for 26 min (37.5 J/cm2). Additional dentures were treated only with PS (P+L-) or light (P-L+) or neither (P-L-). Samples of serial dilutions were spread on Sabouraud dextrose agar and incubated at 37°C for 48 h. The colonies were counted and the values of log (cfu/mL) were analyzed by Kruskall-Wallis and Dunn tests (p<0.05). Results: For all species of Candida, PDT resulted in significant reduction (p<0.05) of cfu/mL values from dentures when compared with P-L- (reductions from 1.73 to 3.99 log10). Significant differences (p<0.05), but lower reductions, were also observed for P+L- and P-L+when compared with P-L- for some species of Candida. Conclusions: PDT was an effective method for reducing Candida spp. on dentures. PMID:21916614

  16. Patient satisfaction and prosthetic aspects with mini-implants retained mandibular overdentures. A 5-year prospective study.

    PubMed

    Elsyad, Moustafa Abdou

    2016-07-01

    This study aimed to evaluate patient satisfaction and prosthetic aspects during a 5-year prospective clinical study of mini dental implants (MDIs) retaining mandibular overdentures. This observational prospective clinical study was conducted on a group of completely edentulous patients (n = 28) with retention problems of conventional mandibular dentures. All patients received new maxillary and mandibular conventional dentures. A total of 112 MDIs (four per patient) were inserted using the flapless surgical approach and immediately loaded by the new mandibular dentures (overdentures). Patients indicated satisfaction with their prosthesis using a questionnaire and a visual analogue scale (VAS). Patient satisfaction and prosthetic complications were recorded 6 months (T6 m ), 1 (T1), 3 (T3), and 5 (T5) years after overdenture insertion. The patient satisfaction with eating (hard/soft) food (P < 0.001), talking (P < 0.001), appearance (P = 0.001), comfort (P < 0.001), healing process (P = 0.013), socialization (P < 0.001), stability/retention of mandibular dentures (P = 0.001), ease of oral hygiene (P = 0.008), and ease of handling the dentures (P < 0.001) increased significantly with time. After 5 years, the most common complication was wear/damage of O/rings (n = 235), O/ring replacement (n = 125), maxillary denture relining times (n = 13), worn teeth (n = 10), overdentures relines (n = 10), detachment of the metal housings (n = 9), and fracture of mandibular overdentures (n = 8). Mucositis, soreness, and decubitis ulcer under overdenture occurred most often at T6 m and decreased significantly with time (P = 0.002, 0.005, and 0.024, respectively). Within the limitations of this clinical study, patient satisfaction with mini-implant retained mandibular overdentures increased significantly with time. However, this treatment required a considerable amount of prosthetic maintenance and repair after 5 years of service. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Maxillary overlay removable partial dentures for the restoration of worn teeth.

    PubMed

    Fonseca, Júlio; Nicolau, Pedro; Daher, Tony

    2011-04-01

    Prolonged tooth maintenance by a more aged population considerably increases the probability of dentists having to treat patients with high levels of tooth wear. Pathological tooth wear, caused primarily by parafunction, seems to be a growing problem that affects a large number of adult patients. The clinical report presents a case of a partially edentulous patient with an elevated degree of wear in the upper jaw caused by attrition and erosion, rehabilitated with a maxillary overlay removable partial denture (ORPD) consisting of a chrome-cobalt (Cr-Co) framework with anterior acrylic resin veneers, posterior cast overlays, and acrylic resin denture bases. Removable partial prosthesis is a treatment alternative when teeth are found to be severely worn or when the patient needs a simple and economical option. Because economics is a conditional factor of the treatment, the clinician should present different treatment alternatives to the patient, in which the overlay prosthesis can be considered.

  18. Prospective cohort pilot study of 2-visit CAD/CAM monolithic complete dentures and implant-retained overdentures: Clinical and patient-centered outcomes.

    PubMed

    Bidra, Avinash S; Farrell, Kimberly; Burnham, David; Dhingra, Ajay; Taylor, Thomas D; Kuo, Chia-Ling

    2016-05-01

    Presently, no studies have evaluated clinical outcomes or patient-centered outcomes for complete dentures fabricated with computer-aided design and computer aided manufacturing (CAD/CAM) technology. The purpose of this prospective cohort pilot study was to evaluate the clinical and patient-centered outcomes for CAD/CAM monolithic dentures fabricated in 2 visits. Twenty participants with an existing set of maxillary complete dentures opposing either mandibular complete dentures or implant-retained overdentures that required replacement were recruited in this study. A 2-visit duplicate denture protocol was used to fabricate 40 arches of monolithic dentures with CAD/CAM technology. A 100-mm visual analog scale (VAS) instrument was then used to record 12 outcomes at baseline and at 1-year follow-up. Predetermined values were assigned to grade the VAS rating of each outcome as favorable (70.1-100) and unfavorable (≤70). Favorable ratings were sub-divided as excellent (90.1-100), good (80.1-90), and fair (70.1-80). The clinical outcomes were evaluated independently by 2 experienced prosthodontists at baseline and at 1-year follow-up. Patients evaluated the corresponding patient-centered outcomes during the same time intervals. Additional descriptive variables were also recorded. Each clinical and patient-centered outcome was summarized by medians and ranges. Differences in all ratings recorded at baseline and at 1 year were tested by 1-sided sign test (α=.05). Of 20 participants, 3 were lost to follow-up, and 3 were unsatisfied with the digital dentures and withdrew from the study. These 3 participants were considered treatment failures. Of the 14 remaining participants, 9 had implant-retained mandibular overdentures, and 5 had conventional mandibular complete dentures. For clinical outcomes, the 12 studied outcomes were favorably evaluated by the 2 prosthodontist judges at the 1-year follow-up. Evaluations showed minimal differences between baseline and 1 year. An average of 5 emails (0-11) per patient were sent to the laboratory technicians to communicate the improvisation the CAD design of the dentures. An average of 3.3 denture adjustments were needed after insertion (0-10) during the 1-year period. For patient-centered outcomes, median ratings of all 14 participants indicated each of the 12 studied outcomes was favorable at the 1-year recall. Statistically significant improvements in patient ratings from baseline to 1 year were observed for the absence of denture sore spots and treatment time to make the dentures (P<.05). Minor complications related to loss of retention, excessive wear of teeth and the need for additional visits were observed in 5 participants. No other adverse clinical outcomes related to the CAD/CAM dentures were noted in the 14 evaluated participants, and all dentures were intact and in good condition at the 1-year follow-up. Clinical and patient-centered outcomes for CAD/CAM monolithic dentures fabricated using a 2-visit protocol were evaluated favorably at a 1-year follow-up. However, the proportion of excellent and good ratings for overall satisfaction and assessment was higher for patients than clinicians. A considerable amount of the clinician's time and effort was devoted to aiding in the digital process for the fabrication of CAD/CAM dentures. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  19. Integrating hinge axis approximation and the virtual facial simulation of prosthetic outcomes for treatment with CAD-CAM immediate dentures: A clinical report of a patient with microstomia.

    PubMed

    Kuric, Katelyn M; Harris, Bryan T; Morton, Dean; Azevedo, Bruno; Lin, Wei-Shao

    2017-09-29

    This clinical report describes a digital workflow using extraoral digital photographs and volumetric datasets from cone beam computed tomography (CBCT) imaging to create a 3-dimensional (3D), virtual patient with photorealistic appearance. In a patient with microstomia, hinge axis approximation, diagnostic casts simulating postextraction alveolar ridge profile, and facial simulation of prosthetic treatment outcome were completed in a 3D, virtual environment. The approach facilitated the diagnosis, communication, and patient acceptance of the treatment of maxillary and mandibular computer-aided design and computer-aided manufacturing (CAD-CAM) of immediate dentures at increased occlusal vertical dimension. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. A randomized clinical trial comparing the efficacy of mandibular implant-supported overdentures and conventional dentures in diabetic patients. Part V: food preference comparisons.

    PubMed

    Roumanas, Eleni D; Garrett, Neal R; Hamada, Michael O; Diener, Randy M; Kapur, Krishan K

    2002-01-01

    The functional benefits of replacing old dentures with new conventional mandibular dentures or implant-supported overdentures has not been fully determined. This study assessed the impact of these 2 types of replacement dentures on the food choices of diabetic patients. A total of 68 diabetic patients with original complete dentures participated in this study. Diabetes was controlled with insulin in 38 patients (IT) and without insulin in 30 patients (NIT). All subjects received conventional maxillary dentures; 25 received mandibular conventional dentures (CD), and 43 received overdentures with plastic clips and a Hader bar attached to 2 osseointegrated implants (IOD). Subjects rated their perceptions of taste acceptability, texture acceptability, and chewing ease on a 4-point nominal scale and eating frequency on a 5-point scale for 13 specific foods at baseline (with original dentures) and at 6 months post-treatment completion (PTC). Fisher exact tests were used to compare the change in percentage distributions of responses with treatment. A 2 x 2 x 2 repeated-measures analysis of variance (ANOVA) was performed to compare mean scores between the 2 denture groups, 2 diabetic groups, and 2 time intervals for each of the 13 foods and 4 questions related to food acceptability. At baseline, no significant differences were found between the frequency distributions of responses in the CD and IOD groups or the IT and NIT groups for all 52 comparisons. With both types of study dentures, a higher percentage of patients perceived deterioration rather than improvement in function. When percentage distributions based on actual positive or negative change (treatment effect) in patient responses were compared, significant differences were found for 3 of the 52 responses, in favor of the IOD group. ANOVA demonstrated significant mean differences for 4 of the 52 comparisons. Both types of study dentures resulted in declines in the perceived taste and texture acceptability of almost all test foods. Declines in perceived chewing ease and eating frequency were more common and greater in the CD than in the IOD group. Both types of study dentures failed to affect food choices, as evidenced by declines or limited improvement in the perceived frequency with which most foods were eaten.

  1. The edentulous mandible opposed by natural maxillary teeth: a report of six cases treated with implant-retained prostheses.

    PubMed

    Clark, R K; Comfort, M B

    1994-01-01

    Dental restoration of the edentulous mandible opposing natural maxillary teeth is often associated with a number of problems, particularly in the occlusion, and an accelerated rate of alveolar bone resorption in the edentulous mandible resulting from occlusal loading. The advent of osseointegrated implants would seem to provide a new means of treating these cases. Accordingly, the cases of six patients for whom either fixed partial dentures or over-dentures supported by Brånemark implants were provided, are reviewed. Three of the mandibles were normal and three had bone grafts. Results so far indicate that this is a viable alternative for treating such cases.

  2. One-year results of maxillary overdentures supported by 2 titanium-zirconium implants - implant survival rates and radiographic outcomes.

    PubMed

    Zembic, Anja; Tahmaseb, Ali; Jung, Ronald E; Wismeijer, Daniel

    2017-07-01

    To assess implant survival rates and peri-implant bone loss of 2 titanium-zirconium implants supporting maxillary overdentures at 1 year of loading. Twenty maxillary edentulous patients (5 women and 15 men) being dissatisfied with their complete dentures were included. In total, 40 diameter-reduced titanium-zirconium implants were placed in the anterior maxilla. Local guided bone regeneration (GBR) was allowed if the treatment did not compromise implant stability. Following 3 to 5 months of healing, implant-supported overdentures were inserted on two ball anchors. Implants and overdentures were assessed at 1, 2, 4, and 8 weeks after implant insertion and 2, 4, and 12 months after insertion of overdentures (baseline). Standardized radiographs were taken at implant loading and 1 year. Implant survival rates and bone loss were the primary outcomes. Nineteen patients (1 dropout) with 38 implants were evaluated at a mean follow-up of 1.1 years (range 1.0-1.7 years). One implant failed resulting in an implant survival rate of 97.3%. There was a significant peri-implant bone loss of the implants at 1 year of function (mean, 0.7 mm, SD = 1.1 mm; median: 0.48 mm, IQR = 0.56 mm). There was a high 1-year implant survival rate for edentulous patients receiving 2 maxillary implants and ball anchors as overdenture support. However, several implants exhibited an increased amount of bone loss of more than 2 mm. Overdentures supported by 2 maxillary implants should thus be used with caution as minimally invasive treatment for specific patients encountering problems with their upper dentures until more long-term data is available. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Photoelastic analysis to compare implant-retained and conventional obturator dentures

    NASA Astrophysics Data System (ADS)

    Goiato, Marcelo Coelho; Prado Ribeiro, Paula do; Pellizzer, Eduardo Piza; Pesqueira, Aldiéris Alves; Haddad, Marcela Filiè; dos Santos, Daniela Micheline; Moreno, Amália

    2012-06-01

    The use of photoelastic analysis contributes to the rehabilitation of patients with oral-sinus-nasal sequelae, which in turn affect important functions such as chewing, swallowing, and speech. The prosthetic rehabilitation with implant-retained dentures is a suitable treatment option. The purpose of this study was to verify, by using a photoelastic analysis, the stress distribution in implant-retained palatal obturator dentures (relined or not) associated with different attachment systems (O-ring, bar-clip, and bar-clip associated with distally placed O-rings). Two photoelastic models were obtained from an experimental maxillary cast presenting an oral-nasal communication. One model had two 13-mm length implants placed on the left region. A total of eight colorless maxillary obturators were fabricated and subsequently four of them were relined with soft silicone soft, and three had attachment systems associated. The assembly (model/attachment system/prosthesis) was positioned in a circular polariscope and a 100-N load was applied at 10 mm/s. The results showed that the denture relining influenced the distribution and amount of stress on the models. The O-ring group displayed the lowest stress levels, followed by bar-clip system associated with distally placed O-rings and bar-clip groups.

  4. Wear rates of artificial denture teeth opposed by natural dentition.

    PubMed

    Douglas, W H; Delong, R; Pintado, M R; Latta, M A

    1993-01-01

    The wear rate of polymeric or composite-based artificial denture teeth on fixed, removable and implant prostheses is important in the maintenance of cuspal form, masticatory efficiency and occlusal stability. A servo-hydraulic based artificial mouth in which an occlusion was established between artificial denture teeth, and the palatal cusp of a human maxillary third molar was established and used to assess the wear resistance of 5 artificial denture tooth materials. Volumetric wear was determined for Dentsply Trublend SLM, Dentsply IPN, Vita Vitapan, Ivoclar Orthotyp and Ivoclar Orthosit denture teeth. Scanning electron microscopy was also done to assess the textural character of the wear facets of each denture tooth sample. The lowest volume loss was observed for Trublend SLM followed by IPN, Orthotyp, Vitapan and Orthosit. Textural assessment of the materials was consistent with the objective wear data.

  5. Impact of facial form on the relationship between conventional or implant-assisted mandibular dentures and masticatory function.

    PubMed

    Ochiai, Kent T; Hojo, Satoru; Nakamura, Camille; Ikeda, Hideki; Garrett, Neal R

    2011-04-01

    It is not clear if the interaction of craniofacial form with type of prosthetic restoration (conventional or implant-assisted) is related to masticatory function in complete denture patients. The purpose of this study was to investigate the relationships among facial form, skeletal class, alveolar residual ridge heights and masticatory function in subjects treated with implant-assisted or conventional mandibular dentures with lateral cephalometric evaluation. Data from a previously reported randomized controlled clinical trial were accessed to compare treatment success rates, functional and perceptual outcomes, dietary intake, and craniofacial relationships between mandibular complete dentures and implant overdentures in edentulous diabetic subjects. Evaluation of the digitized post-insertion lateral cephalometric radiographs provided measures of facial form (mesocephalic "medium", brachycephalic "broad and square", dolichocephalic "vertical and long"), skeletal class (Class I, Class II, Class III), and alveolar ridge height (mm), which were compared to results of standardized masticatory tests as evaluated using MANOVA and REGW post-hoc evaluation (α=.05). Masticatory performance on the preferred side was slightly reduced in the dolichocephalic group, compared to brachycephalic and mesocephalic groups (P=.085). Swallowing threshold performance was significantly less in skeletal Class II subjects compared to Class I (P=.034). Maxillary residual alveolar ridge height was significantly less in the brachycephalic group compared to the dolichocephalic group (P<.001). No differences in mandibular ridge height were seen associated with facial form or skeletal class groups. Facial form may be related to masticatory function with conventional and implant-assisted mandibular dentures, but larger controlled studies are needed to confirm this relationship. Alveolar ridge height is reduced in edentulous subjects with a brachycephalic facial form. Copyright © 2011 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  6. Bond Potential of Lithium Disilicate to Heat-Cured Polymethylmethacrylate (PMMA)

    DTIC Science & Technology

    2016-06-07

    Restitution of maxillary anterior esthetics with all-ceramic components. International Dental Journal , 52(1): 47-56. Albarky M, Guazzato M, Swain MV...2004). An introduction to silanes and their clinical applications in dentistry. The International Journal of Prosthodontics, 17(2): 155-164...autopolymerizing denture resin and light cured composite resin to denture teeth. International Dental Journal , 52(1): 20-24. Zarb GA and Bolender

  7. Creating natural-looking removable prostheses: combining art and science to imitate nature.

    PubMed

    Patras, Michael; Kourtis, Stefanos; Sykaras, Nikitas

    2012-06-01

    Patient awareness of dental appearance has increased, resulting in more demanding esthetic requests. There is also strong evidence that increased esthetics is highly significant for complete denture acceptance and success. Taking notice of patients' perceptions of natural appearance and esthetics, the clinician can incorporate their preferences in the construction of individualized dentures that will be harmonized with their facial characteristics. Despite the evolution of materials and techniques, the vast majority of dentures still fail to look natural. Thus, producing prostheses that defy detection and successfully restore the appearance of edentulous patients remains a challenge for the clinician. This paper presents a clinical case where immediate loading of implants supporting a mandibular overdenture was combined with an opposing conventional maxillary denture to satisfy the high functional and esthetic demands of the patient. It also emphasizes the individualized esthetic performance through customization during their fabrication while taking into consideration the various clinical parameters affecting rehabilitation of the edentulous jaw. Implant-retained overdentures can significantly improve the patients' function. The esthetic performance of these restorations however, may not be satisfying the patients' expectations and demands. Customizing the artificial gingival areas and individual staining of the prefabricated acrylic teeth may improve the esthetic performance creating natural-looking removable prostheses. © 2011 Wiley Periodicals, Inc.

  8. Evaluation of the efficacy of mandibular conventional and implant prostheses in a group of Turkish patients: a quality of life study.

    PubMed

    Cakir, Onur; Kazancioglu, Hakki Oguz; Celik, Gozde; Deger, Sabire; Ak, Gulsum

    2014-07-01

    The aim of this study was to compare the satisfaction and quality of life (QoL) in a group of patients using mandibular complete dentures, implant-retained overdentures, removable partial dentures (RPDs), or implant-supported fixed partial dentures (FPDs). A total of 116 patients (aged 36 to 81, mean age 58 ± 10.03 years) were assigned to four groups (n = 29) and treated with mandibular implant-retained overdentures, implant-supported FPDs (two implants/three unit FPDs), conventional complete dentures, or RPDs. The groups were well matched in terms of gender, age, and the edentulous period. All patients had edentulous maxillary arches and completely or partially edentulous mandibles. All prostheses were mandibular prostheses. The OHIP-14, OHQoL-UK, and SF-36 surveys were used to determine QoL before implant surgery and 1 year after prosthetic treatment. The baseline and 1-year data from 116 patients were analyzed. A significant improvement was found among the QoL scales for all groups (p < 0.05). The most significant improvement was found in the implant-retained overdenture group (15.67 ± 2.47), while the least improvement was found among the implant-supported FPD group (5.14 ± 2.08). The SF-36 test revealed no differences between the before and after treatment scores for general health, pain, vitality, social function, and physical function difficulties (p > 0.05). The only significant difference was found for mental health (p = 0.011). A positive influence on oral health-related QoL was observed in all groups. The QoL values were the most improved in the implant-retained overdenture group. © 2014 by the American College of Prosthodontists.

  9. Effect of Attachment Type on Implant Strain in Maxillary Implant Overdentures: Comparison of Ball, Locator, and Magnet Attachments. Part 1. Overdenture with Palate.

    PubMed

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    Implant overdentures with attachments have been used in clinical practice and the effect of attachments on implant strain has been frequently reported. However, most studies have focused on mandibular overdentures; there are few reports on maxillary overdentures. The purpose of this study was to examine the influence of attachment type on implant strain in maxillary overdentures under various implant configurations. A maxillary edentulous model with implants and experimental overdentures were fabricated. Four strain gauges were attached to each implant, positioned in anterior, premolar, and molar areas. Three types of unsplinted attachments-ball, locator, and magnet-were set on the implants under various implant configurations. A vertical occlusal load of 98 N was applied through the mandibular complete denture, and implant strain was compared using the Kruskal-Wallis test. Ball attachments caused the greatest amount of strain, while magnet attachments caused the least amount under all conditions. For all attachments, two anterior implants caused significantly more strain than four implants (P < .05). No significant difference was observed between subtypes in four-implant configurations except when using locator attachments. When using unsplinted attachments for maxillary implant overdentures, magnet attachments are recommended to reduce implant stress. Using only two implants, especially two anterior implants, is not recommended regardless of attachment type.

  10. Using implants for prosthodontic rehabilitation of a 4-year-old with ectodermal dysplasia.

    PubMed

    Toomarian, Lida; Ardakani, Mohammad Reza Talebi; Ramezani, Jamileh; Adli, Amin Rezaei; Tabari, Zahra Alizadeh

    2014-01-01

    Ectodermal dysplasia (ED) is an inherited disorder that affects ectodermally derived organs, such as teeth. Pathogenesis is thought to involve an altered epithelium-mesenchymal interaction. ED patients have oligodontia (or sometimes anodontia) in addition to other abnormalities involving the skin, sweat glands, or hair. Many different subtypes have been introduced in the literature. This article describes the case of a 4-year-old patient who, after being diagnosed with ED, was put on a treatment plan that involved mandibular implants, reshaping of the maxillary primary central incisors, and prosthetic dental rehabilitation. Due to the child's rapid growth, both dentures were changed 9 months post-treatment. Two years post-treatment, the maxillary denture was changed again and the child was placed under close supervision.

  11. Tooth-related risk factors for periodontal disease in community-dwelling elderly people.

    PubMed

    Hirotomi, Toshinobu; Yoshihara, Akihiro; Ogawa, Hiroshi; Miyazaki, Hideo

    2010-06-01

    While most previous epidemiological studies have focused on subject-level risk factors for periodontal destruction, tooth-related factors have not been fully explored. The purpose of this study was to evaluate both tooth-related and subject-related factors affecting periodontal disease progression using a two-level multilevel model. A longitudinal survey over a period of 10 years was carried out on 286 community-dwelling elderly subjects aged 70 years at baseline. Clinical attachment level (CAL) was measured at six sites per tooth on all teeth present and periodontal disease progression was defined as CAL> or =3 mm. Periodontal disease progression was found in 79% of the subjects and most frequently in maxillary molars. Multilevel logistic regressions revealed that subjects wearing removable dentures were significantly at risk for periodontal disease progression. Abutment teeth for removable/fixed dentures were also significantly more likely to suffer periodontal breakdown. Furthermore, the following tooth-related variables were found to be possible risk factors for periodontal disease progression: maxillary and multirooted teeth. Multirooted teeth and abutments for a fixed denture were possible risk factors for periodontal disease progression.

  12. A multispecies probiotic reduces oral Candida colonization in denture wearers.

    PubMed

    Ishikawa, Karin H; Mayer, Marcia P A; Miyazima, Tatiana Y; Matsubara, Victor H; Silva, Eriques G; Paula, Claudete R; Campos, Tomie T; Nakamae, Atlas E M

    2015-04-01

    The prevalence of Candida infections has been rising with an increasingly aging population and a larger population of immunocompromised individuals. The use of probiotics may be an alternative approach to antifungal agents in the prevention and treatment of oral candidiasis. This study aimed to evaluate the short-term effect of probiotics in reducing the infection level of oral Candida in candidiasis-asymptomatic elderly denture wearers. In a double-blind randomized study, 59 denture wearers harboring Candida spp. in the oral cavity with no clinical symptoms were allocated into two groups: probiotic and placebo. All patients were instructed to clean the denture daily. The probiotic group poured a capsule containing lyophilized Lactobacillus rhamnosus HS111, Lactobacillus acidophillus HS101, and Bifidobacterium bifidum daily on the palatal surface of the maxillary denture, whereas the placebo group was submitted to the same regimen using placebo capsules. Candida spp. infection levels were evaluated in palate mucosa samples obtained before and after a 5-week experimental period. All patients harbored Candida in the palate mucosa at baseline. Fifty-five individuals completed the experimental period. The detection rate of Candida spp. was 92.0% in the placebo group after the experimental period, whereas it was reduced to 16.7% in the probiotic group. The reduction promoted by the probiotic regimen was independent of baseline characteristics such as Candida infection level and colonizing species, age of denture, and other variables. The probiotic product was effective in reducing the colonization of the oral cavity with Candida in candidiasis-asymptomatic elderly denture wearers, suggesting that this multispecies probiotic could be used to prevent oral candidiasis. Colonization of oral surfaces by Candida is considered a risk factor for invasive fungal infections. The use of a product with L. rhamnosus, L. acidophilus, and B. bifidum may represent an alternative treatment for reduction of Candida infections in elderly denture wearers. © 2014 by the American College of Prosthodontists.

  13. Tissue-supported dental implant prosthesis (overdenture): the search for the ideal protocol. A literature review

    PubMed Central

    Laurito, Domenica; Lamazza, Luca; Spink, Michael J.; De Biase, Alberto

    2012-01-01

    Summary Aims The success of maxillary and mandibular tissue supported implant prostheses varies in the literature, and the ideal protocol may be elusive from given the numerous studies. The oral rehabilitation option is an alternative to conventional dentures and should improve function, satisfaction, and retention. The purpose of this review article is to clarify these questions. Methods The search of literature reviews English non-anecdotal implant overdentures articles from 1991 to 2011. Results The results display an aggregate comprehensive list of categorical variables from the literature review. Overall success of maxillary and mandibular implant overdenture was respectively, 86.6% and 95.8%. Conclusion The literature indicates that the implant overdenture prosthesis provides predictable results – enhanced stability, function and a high-degree of satisfaction compared to conventional removable dentures. PMID:22783448

  14. A 5-year randomized trial to compare 1 or 2 implants for implant overdentures.

    PubMed

    Bryant, S R; Walton, J N; MacEntee, M I

    2015-01-01

    The hypothesis of this 5-y randomized clinical trial was that there would be no significant difference in the satisfaction of edentulous participants with removable complete overdentures attached to 1 or 2 mandibular implants. Secondary aims were to test changes in satisfaction between and within the groups from baseline to 5 y and differences between the groups in implant survival and prosthodontic maintenance over 5 y. Each of the 86 participants (mean age, 67 y) was randomly allocated to receive either 1 implant in the midline (group 1) or 2 implants in the canine areas (group 2) attached to a mandibular overdenture opposing a maxillary complete denture. Satisfaction was self-assessed by participants on a visual analog scale at baseline prior to implants, as well as at 2 mo and 1, 3, and 5 y with implant overdentures, whereas implant survival and prosthodontic maintenance were assessed by clinical examination. After 5 y, 29 participants in group 1 and 33 in group 2 were available, with most dropouts due to death. Satisfaction with the implant denture after 5 y was significantly (P < 0.001) higher than at baseline in both groups and remained with no significant difference (P = 0.32) between the groups. No implants failed in group 1 but 5 failed before loading in 4 participants in group 2. Most participants required maintenance or occasionally denture replacement, and although differences between the groups were not statistically significant, group 1 experienced almost twice as many fractured dentures usually adjacent to the implant attachment. We conclude that there were no significant differences after 5 y in satisfaction or survival of implants with mandibular overdentures retained by 1 implant or 2 implants. Additional research is required to confirm long-term treatment effectiveness of single-implant dentures and the implications of prosthetic maintenance with implant overdentures (ClinicalTrials.gov: NCT02117856). © International & American Associations for Dental Research 2014.

  15. Reestablishment of occlusion through overlay removable partial dentures: a case report.

    PubMed

    Bataglion, César; Hotta, Takami Hirono; Matsumoto, Wilson; Ruellas, Carlos Ventura de Oliveira

    2012-01-01

    Loss of posterior teeth may cause an imbalance in the stomatognathic system. Overlay removable partial dentures (ORPD) are a reversible and relatively inexpensive treatment for patients with severely worn teeth. This paper presents a treatment with ORPD in a 55-year-old male patient who had severe attrition in the maxillary and mandibular teeth, temporomandibular joint pain and reduced vertical dimension of occlusion (VDO). The treatment consisted in the reestablishment of the VDO using Lucia's jig, fabricating removable partial denture with reconstruction of the worn teeth without preparation. This therapy can be used as an alternative treatment to provide esthetic, function and stable occlusion in patients with severely worn teeth.

  16. Correlation between Visible Length of the Iris and the Length of the Maxillary Central Incisor Using Digital Image Analysis- A Pilot Study.

    PubMed

    Rohini; Hemalatha; Chander, Gopi Naveen; Anitha, Kuttae Viswanathan

    2017-02-01

    Complete denture therapy is one such modality where science and art goes hand in hand. Selection of artificial teeth for completely edentulous patients is not easy in the absence of pre extraction records, because till date concrete guidelines do not exist. The purpose of this study was to determine if a correlation existed between the visible length of the iris and the length of the maxillary central incisor to potentially provide a guide for teeth selection. A total of 20 Indian dental students consented to participate in the pilot study. Standardized digital images of the face revealing the eyes and component of teeth on smiling was captured using a digital camera. The digital measurements of the visible iris length (medial aperture height, tangential to iris) and the length of the maxillary central incisor from the zenith to the incisal edge were analysed using Adobe Photoshop creative cloud software. The data was statistically evaluated and results were tabulated. Karl Pearson's Coefficient of Correlation was utilized to detect if any association existed between the two variables. The mean value of length of central incisor was 10.39 mm and the mean value of the visible length of iris was found to be 12.9 mm. A Pearson correlation analysis revealed an r-value <0.3 indicating minimal association between the two variables with a p-value >0.01 (.322). On inference, the correlation between the visible iris length and that of maxillary central incisor were unable to produce a strong positive statistical association. However, an association factor between the two has been obtained. Deduction of 2.5 mm from the dimension of visible iris length will help in attaining the length of artificial maxillary central incisor tooth.

  17. Effects of mechanical properties of adhesive resin cements on stress distribution in fiber-reinforced composite adhesive fixed partial dentures.

    PubMed

    Yokoyama, Daiichiro; Shinya, Akikazu; Gomi, Harunori; Vallittu, Pekka K; Shinya, Akiyoshi

    2012-01-01

    Using finite element analysis (FEA), this study investigated the effects of the mechanical properties of adhesive resin cements on stress distributions in fiber-reinforced resin composite (FRC) adhesive fixed partial dentures (AFPDs). Two adhesive resin cements were compared: Super-Bond C&B and Panavia Fluoro Cement. The AFPD consisted of a pontic to replace a maxillary right lateral incisor and retainers on a maxillary central incisor and canine. FRC framework was made of isotropic, continuous, unidirectional E-glass fibers. Maximum principal stresses were calculated using finite element method (FEM). Test results revealed that differences in the mechanical properties of adhesive resin cements led to different stress distributions at the cement interfaces between AFPD and abutment teeth. Clinical implication of these findings suggested that the safety and longevity of an AFPD depended on choosing an adhesive resin cement with the appropriate mechanical properties.

  18. A subperiosteal maxillary implant causing severe osteolysis.

    PubMed

    Maï, Nguyen Tan; Jean-Baptiste, Caruhel; Hossein, Khonsari Roman

    2018-06-22

    Subperiosteal implant denture therapy was initially introduced in 1942 in Sweden and was then used worldwide for the treatment of fully edentulous maxillary or mandibular arches with advanced bone atrophy. Most authors describe decent success rates for mandibular subperiosteal implants in cases with major bone atrophy but follow-up studies for maxillary subperiosteal implants are not available. Here, we report a case of severe maxillary osteolysis secondary to the placement of a subperiosteal in-house implant. Subperiosteal implants are rarely used today but patients still carrying these devices with severe complications can be challenging to manage. New technical advances, including the use of surgical planification and additive manufacturing, may lead to a new interest in subperiosteal implants. Copyright © 2018. Published by Elsevier Masson SAS.

  19. Masticatory efficiency and oral health-related quality of life with implant-retained mandibular overdentures

    PubMed Central

    Sun, Xu; Zhai, Jun-Jiang; Liao, Jian; Teng, Min-Hua; Tian, Ai; Liang, Xing

    2014-01-01

    Objectives: To evaluate masticatory efficiency (ME) and oral health-related quality of life (OHRQoL) in patients rehabilitated with implant-retained mandibular overdentures. Methods: In this randomized controlled clinical trial, 50 edentulous patients visiting the Implant Center and Department of Prosthodontics, West China College of Stomatology, Sichuan University, Chengdu, China between June 2010 and June 2012 were selected and received 2 implant-retained mandibular overdenture treatments. All patients were rehabilitated with maxillary complete dentures. The ME and OHRQoL were determined both one month before the mandibular complete denture was anchored to the osseointegrated implants, and 6 months after anchoring. Paired t-tests were used to compare means of ME, and oral health impact profile-49 (OHIP-49) domains scores between pre- and post-implant. Linear regression models were utilized to seek correlations between ME and OHIP domains scores. Results: The ME increased from pre- to post-implant retained mandibular overdentures significantly (p<0.001). The total OHIP score and 4 subscales scores were changed significantly from pre- to post-implant; namely, functional limitation, psychological discomfort, physical disability, and physical pain. The total OHIP score, functional limitation, physical disability, and physical pain subscale scores were related to ME. Conclusion: Implant-retained mandibular over dentures can significantly improve patients’ ME and OHRQoL. The improvement in OHRQoL is mainly because of the improved ME. An improved chewing experience, and pain relief also contributes to improvement of OHRQoL. PMID:25316463

  20. Differences in Lip Support with and without Labial Flanges in a Maxillary Edentulous Population - Part 3: Unblinded and Discriminatory Subjective Analysis.

    PubMed

    Bidra, Avinash S; Nguyen, Viensuong; Manzotti, Anna; Kuo, Chia-Ling

    2018-01-01

    To study the subjective differences in direct lip support assessments and to determine if dentists and laypeople are able to discern and correctly identify direct changes in lip support between flange and flangeless dentures. A random sample of 20 maxillary edentulous patients described in part 2 of the study was used for analysis. A total of 60 judges comprising 15 general dentists, 15 prosthodontists, and 30 laypeople, the majority of who were distinct from part 2 of the study, were recruited. All images used in this study were cropped at the infraorbital level and converted to black and white tone, to encourage the judges to focus on lip support. The judges were un-blinded to the study objectives and told what to look for, and were asked to rate the lip support of each of the 80 images on a 100 mm visual analog scale (VAS). The judges then took a discriminatory sensory analysis test (triangle test) where they were required to correctly identify the image with a flangeless denture out of a set of 3 images. Both the VAS and triangle test ratings were conducted twice in a random order, and mean ratings were used for all analyses. The overall VAS ratings of lip support for images with flangeless dentures were slightly lower compared to images with labial flanges, and this difference was statistically significant (p < 0.0001). This was true for both profile and frontal images. However, the magnitude of these differences was too small (no greater than 5 mm on a 100-mm scale) to be clinically significant or meaningful. The differences in VAS ratings were not significant between the judges. For the triangle test, judges overall correctly identified the flangeless denture image in 55% of frontal image sets and 60% of profile image sets. The difference in correct identification rate between frontal and profile images was statistically significant (p < 0.0001). For frontal and profile images, prosthodontists had the highest correct identification rate (61% and 69%), followed by general dentists (53% and 68%) and by laypeople (53% and 50%). The difference in correct identification rate was statistically significant between various judges (p = 0.012). For all judges, the likelihood of correctly identifying images with flangeless dentures was significantly greater than 1/3, which was the minimum chance for correct identification (p < 0.0001). Removal of a labial flange in a maxillary denture resulted in slightly lower ratings of lip support compared to images with a labial flange, but the differences were clinically insignificant. When judges were forced to look for differences, flangeless dentures were detected more often in profile images. Prosthodontists detected the flangeless dentures more often than general dentists and laypeople. © 2017 by the American College of Prosthodontists.

  1. Therapeutical attitudes in tooth supported overdentures with ball attachements. Case report

    PubMed Central

    Țâncu, AM; Melescanu Imre, M; Preoteasa, CT; Preoteasa, E

    2014-01-01

    Tooth supported overdenture with ball attachments has a number of advantages in prosthetics, but presents some difficulties as well, which sometimes make impossible the use of these anchoring systems; these difficulties should be well known. In this regard we present a suggestive case. It is the case of a patient, aged 57, who came for treatment, suffering from subtotal maxillary and mandibular edentulism (present 11 and 21, respectively 33 and 43), previously having an overdenture prosthesis on natural teeth, with special systems – ball attachment type, dissatisfied with the treatment (due to repeated fractures and functional intolerance to dentures). Clinical examination revealed an increase of the vertical dimension of occlusion and reduced prosthetic space at a correct, functional DVO value, aspects that were explaining the patient’s reported complaints. As a therapeutic approach, having into consideration the balance conditions that were favorable for complete dentures and the large ball attachments volume, which did not allow keeping them at a functional DVO at any of the jaws, and the relatively young age of the patient, it was decided to remove the ball attachments and to keep the teeth for a simple overdenture, both to the maxillar and the mandible, over coronary reduced teeth, enough to allow the denture thickness at a functional DVO. Good end result of prosthetics, with stable, functional dentures, which were well tolerated and offered satisfaction to the patient, have led to an increased quality of life. PMID:27057258

  2. Therapeutical attitudes in tooth supported overdentures with ball attachements. Case report.

    PubMed

    Țâncu, A M; Melescanu Imre, M; Preoteasa, C T; Preoteasa, E

    2014-01-01

    Tooth supported overdenture with ball attachments has a number of advantages in prosthetics, but presents some difficulties as well, which sometimes make impossible the use of these anchoring systems; these difficulties should be well known. In this regard we present a suggestive case. It is the case of a patient, aged 57, who came for treatment, suffering from subtotal maxillary and mandibular edentulism (present 11 and 21, respectively 33 and 43), previously having an overdenture prosthesis on natural teeth, with special systems - ball attachment type, dissatisfied with the treatment (due to repeated fractures and functional intolerance to dentures). Clinical examination revealed an increase of the vertical dimension of occlusion and reduced prosthetic space at a correct, functional DVO value, aspects that were explaining the patient's reported complaints. As a therapeutic approach, having into consideration the balance conditions that were favorable for complete dentures and the large ball attachments volume, which did not allow keeping them at a functional DVO at any of the jaws, and the relatively young age of the patient, it was decided to remove the ball attachments and to keep the teeth for a simple overdenture, both to the maxillar and the mandible, over coronary reduced teeth, enough to allow the denture thickness at a functional DVO. Good end result of prosthetics, with stable, functional dentures, which were well tolerated and offered satisfaction to the patient, have led to an increased quality of life.

  3. Do implant overdentures improve dietary intake? A randomized clinical trial.

    PubMed

    Hamdan, N M; Gray-Donald, K; Awad, M A; Johnson-Down, L; Wollin, S; Feine, J S

    2013-12-01

    People wearing mandibular two-implant overdentures (IOD) chew food with less difficulty than those wearing conventional complete dentures (CD). However, there is still controversy over whether or not this results in better dietary intake. In this randomized clinical trials (RCT), the amounts of total dietary fiber (TDF), macronutrients, 9 micronutrients, and energy in diets consumed by persons with IOD and CD were compared. Male and female edentate patients ≥ 65 yrs (n = 255) were randomly divided into 2 groups and assigned to receive a maxillary CD and either a mandibular IOD or a CD. One year following prosthesis delivery, 217 participants (CD = 114, IOD = 103) reported the food and quantities they consumed to a registered dietician through a standard 24-hour dietary recall method. The mean and median values of TDF, macro- and micronutrients, and energy consumed by both groups were calculated and compared analytically. No significant between-group differences were found (ps > .05). Despite quality-of-life benefits from IODs, this adequately powered study reveals no evidence of nutritional advantages for independently living medically healthy edentate elders wearing two-implant mandibular overdentures over those wearing conventional complete dentures in their dietary intake at one year following prosthesis delivery.

  4. Comparative evaluation of sodium hypochlorite and microwave disinfection on dimensional stability of denture bases.

    PubMed

    Nirale, Rutuja Madhukarrao; Thombre, Ram; Kubasad, Girish

    2012-02-01

    To compare the effect of sodium hypochlorite and microwave disinfection on the dimensional stability of denture bases without and with relining. A brass die was prepared by simulating an edentulous maxillary arch. It was used to fabricate 1.5 mm and 3 mm of thickness denture bases (n = 40). The 1.5 mm of thickness-specimens (n = 20) were relined with 1.5 mm of autopolymerizing relining resin. Five holes were prepared over crest of ridge of brass die with intimately fitting stainless steel pins which were transferred to the intaglio surface of specimens during fabrication of denture bases. For calculation of dimensional changes in denture bases, differences between the baseline area before and after disinfection of the specimens were used. The denture bases without and with relining were divided into 2 groups (each n = 20). Data were analyzed using student paired 't' and unpaired 't' test. Microwave disinfection produces significant shrinkage in both denture bases without relining (t = 17.16; P<.001) and with relining (t = 14.9; P<.001). Denture bases without relining showed more shrinkage when compared with relined denture bases after microwave disinfection (t = 6.09; P<.001). The changes in dimensional stability after sodium hypochlorite disinfection were not significant for both denture bases without relining (t = 2.19; P=.056) and denture bases with relining (t = 2.17; P=.058). Microwave disinfection leads to increased shrinkage of denture bases without and with relining. Chemical disinfection with sodium hypochlorite seems to be a safer method of disinfection with regards to physical properties such as changes in dimensional stability.

  5. Neuromuscular coordination of masticatory muscles in subjects with two types of implant-supported prostheses.

    PubMed

    Ferrario, Virgilio F; Tartaglia, Gianluca M; Maglione, Michele; Simion, Massimo; Sforza, Chiarella

    2004-04-01

    To compare the electromyographic (EMG) characteristics of masticatory muscles in patients with fixed implant-supported prostheses and implant overdentures. Nineteen subjects aged 45-79 years were examined. Fourteen were edentulous and had been successfully rehabilitated with (a) maxillary and mandibular implant-supported fixed prostheses (seven patients); (b) mandibular implant overdentures and maxillary complete dentures (seven patients). Five control subjects had natural dentition or single/partial (no more than two teeth) tooth or implant fixed dentures. Surface EMG of the masseter and temporal muscles was performed during unilateral gum chewing and during maximum teeth clenching. To reduce biological and instrumental noise, all values were standardized as percentage of a maximum clenching on cotton rolls. During clenching, temporal muscle symmetry was larger in control subjects and fixed implant-supported prosthesis patients than in overdenture patients (analysis of variance, P=0.005). No differences were found in masseter muscle symmetry or in muscular torque. Muscle activities (integrated areas of the EMG potentials over time) were significantly larger in control subjects than in implant-supported prosthesis patients (P=0.014). In both patient groups, a poor neuromuscular coordination during chewing, with altered muscular patterns, and a smaller left-right symmetry than in control subjects were found (P=0.05). No differences in masticatory frequency were found. Surface EMG analysis of clenching and chewing showed that fixed implant-supported prostheses and implant overdentures were functionally equivalent. Neuromuscular coordination during chewing was inferior to that found in subjects with natural dentition.

  6. A first experience with digital complete overdentures.

    PubMed

    Bajunaid, Salwa Omar

    2016-07-01

    The development of computer-aided design/computer-aided manufacturing systems for dentistry in the 1980s resulted in the successful fabrication of crowns, fixed dental prostheses, and superstructures for both natural teeth and dental implants. Today, this technology is available for constructing digitally designed and milled, completely removable dental prostheses. The procedure uses clinical and laboratory protocols that allow fabrication of completely removable prostheses within two clinical appointments. The aim of this clinical report is to present the author's first experience with digital complete overdentures, the practicality of this technology, and patient feedback. Compared with conventional overdentures, the fit of the digital prostheses was improved because the cameo and flanges of the prostheses were nicely shaped and rolled, and this enhanced their stability and retention. Occlusion was also excellent. However, aesthetics in terms of the alignment, shape, and size of the maxillary overdenture teeth were inacceptable. Despite some of the drawbacks identified in our study, the use of removable digital dentures does provide excellent adaptation of the denture base and requires fewer clinic visits. We anticipate that the unsatisfactory aesthetic outcomes presented in this report can be corrected with more experience. We also believe that acquiring an in-house scanning machine would be beneficial. We highly recommend including this technique in dental school curriculums at both the undergraduate and graduate levels in order to keep students and residents up to date on the latest technology available.

  7. Design of Complete Dentures by Adopting CAD Developed for Fixed Prostheses.

    PubMed

    Li, Yanfeng; Han, Weili; Cao, Jing; Iv, Yuan; Zhang, Yue; Han, Yishi; Shen, Yi; Ma, Zheng; Liu, Huanyue

    2018-02-01

    The demand for complete dentures is expected to increase worldwide, but complete dentures are mainly designed and fabricated manually involving a broad series of clinical and laboratory procedures. Therefore, the quality of complete dentures largely depends on the skills of the dentist and technician, leading to difficulty in quality control. Computer-aided design and manufacturing (CAD/CAM) has been used to design and fabricate various dental restorations including dental inlays, veneers, crowns, partial crowns, and fixed partial dentures (FPDs). It has been envisioned that the application of CAD/CAM technology could reduce intensive clinical/laboratory work for the fabrication of complete dentures; however, CAD/CAM is seldom used to fabricate complete dentures due to the lack of suitable CAD software to design virtual complete dentures although the CAM techniques are in a much advanced stage. Here we report the successful design of virtual complete dentures using CAD software of 3Shape Dental System 2012, which was developed for designing fixed prostheses instead of complete dentures. Our results demonstrated that complete dentures could be successfully designed by the combination of two modeling processes, single coping and full anatomical FPD, available in the 3Shape Dental System 2012. © 2016 by the American College of Prosthodontists.

  8. Dentist-Patient Communication and Denture Quality Associated with Complete Denture Satisfaction Among Taiwanese Elderly Wearers.

    PubMed

    Chen, Jen-Hao; Huang, Hsiao-Ling; Lin, Ying-Chun; Chou, Tsau-Mau; Ebinger, John; Lee, Huey-Er

    2015-01-01

    The aim of this study was to explore individual (ie, sociodemographic characteristics, patient personality) and clinical factors (ie, dentist-patient communication, denture quality) associated with complete denture satisfaction among the Taiwanese elderly population. A multistage sampling and cross-sectional design was used to collect data. A total of 387 fully edentulous citizens, aged 65 years and older and who had received new sets of complete dentures, were selected. The participants completed clinical dental examinations and questionnaires by personal interview to collect information on denture satisfaction and associated variables. The relationship among three groups of these participants (satisfied, neutral, and dissatisfied) and potential factors were simultaneously examined using polytomous logistic regression analysis. Overall, 36.7% of the participants were dissatisfied with their dentures. Living status (crude odds ratio [COR] = 2.04), personality (COR = 4.86), dentist-patient communication (COR = 7.46), and denture quality (COR = 5.02) were associated with complete denture satisfaction. The multivariate regression model showed that dentist-patient communication (adjusted odds ratio [AOR] = 6.41) and denture quality (AOR = 4.40) were significant complete denture satisfaction factors that diluted the effect of living status and personality. Inadequate dentistpatient communication and low denture quality were associated with the dissatisfaction of patients with dentures. To increase complete denture satisfaction, the importance of training programs aimed at enhancing dentist-patient communication and denture quality cannot be overemphasized.

  9. Stress analysis in oral obturator prostheses: imaging photoelastic

    NASA Astrophysics Data System (ADS)

    Pesqueira, Aldiéris Alves; Goiato, Marcelo Coelho; dos Santos, Daniela Micheline; Haddad, Marcela Filié; Andreotti, Agda Marobo; Moreno, Amália

    2013-06-01

    Maxillary defects resulting from cancer, trauma, and congenital malformation affect the chewing efficiency and retention of dentures in these patients. The use of implant-retained palatal obturator dentures has improved the self-esteem and quality of life of several subjects. We evaluate the stress distribution of implant-retained palatal obturator dentures with different attachment systems by using the photoelastic analysis images. Two photoelastic models of the maxilla with oral-sinus-nasal communication were fabricated. One model received three implants on the left side of the alveolar ridge (incisive, canine, and first molar regions) and the other did not receive implants. Afterwards, a conventional palatal obturator denture (control) and two implant-retained palatal obturator dentures with different attachment systems (O-ring; bar-clip) were constructed. Models were placed in a circular polariscope and a 100-N axial load was applied in three different regions (incisive, canine, and first molar regions) by using a universal testing machine. The results were photographed and analyzed qualitatively using a software (Adobe Photoshop). The bar-clip system exhibited the highest stress concentration followed by the O-ring system and conventional denture (control). Images generated by the photoelastic method help in the oral rehabilitator planning.

  10. Comparative evaluation of sodium hypochlorite and microwave disinfection on dimensional stability of denture bases

    PubMed Central

    Thombre, Ram; Kubasad, Girish

    2012-01-01

    PURPOSE To compare the effect of sodium hypochlorite and microwave disinfection on the dimensional stability of denture bases without and with relining. MATERIALS AND METHODS A brass die was prepared by simulating an edentulous maxillary arch. It was used to fabricate 1.5 mm and 3 mm of thickness denture bases (n = 40). The 1.5 mm of thickness-specimens (n = 20) were relined with 1.5 mm of autopolymerizing relining resin. Five holes were prepared over crest of ridge of brass die with intimately fitting stainless steel pins which were transferred to the intaglio surface of specimens during fabrication of denture bases. For calculation of dimensional changes in denture bases, differences between the baseline area before and after disinfection of the specimens were used. The denture bases without and with relining were divided into 2 groups (each n = 20). Data were analyzed using student paired 't' and unpaired 't' test. RESULTS Microwave disinfection produces significant shrinkage in both denture bases without relining (t = 17.16; P<.001) and with relining (t = 14.9; P<.001). Denture bases without relining showed more shrinkage when compared with relined denture bases after microwave disinfection (t = 6.09; P<.001). The changes in dimensional stability after sodium hypochlorite disinfection were not significant for both denture bases without relining (t = 2.19; P=.056) and denture bases with relining (t = 2.17; P=.058). CONCLUSION Microwave disinfection leads to increased shrinkage of denture bases without and with relining. Chemical disinfection with sodium hypochlorite seems to be a safer method of disinfection with regards to physical properties such as changes in dimensional stability. PMID:22439097

  11. Effect of potentially chromogenic beverages on shear bond strength of acrylic denture teeth to heat-polymerized denture base resins

    PubMed Central

    Neppelenbroek, Karin Hermana; Urban, Vanessa Migliorini; de Oliveira, Denise Gusmão; Porto, Vinícius Carvalho; Almilhatti, Hercules Jorge; Campanha, Nara Hellen

    2016-01-01

    Background: Detachment of denture acrylic resin artificial teeth from denture base resin is one of the most common problems presented by denture wearers. Purpose: This study investigated the shear bond strength (SBS) and fracture type of bonding interface of two commercial acrylic teeth (Vipi Dent Plus e Biolux) to two denture base resins (Vipi Cril e Lucitone 550) after immersion in potentially chromogenic beverages (coffee, cola soft drink, and red wine) or control solution (distilled water). Materials and Methods: Maxillary central incisor acrylic teeth were placed at 45° to denture base resin and submitted to short polymerization cycle according to manufacturers. Specimens were divided according to the combination tooth/resin/solution (n = 8) and submitted to bond strength tests in a universal testing machine MTS-810 (0.5 mm/min). Subsequently, fracture area was analyzed by stereomicroscope at a magnification of ×10 and categorized into adhesive, cohesive, or mixed failure. Results: The bond strength of teeth/denture base resins interface was not significantly affected by tested solutions (P > 0.087), except for Biolux teeth immersed in coffee (P < 0.01). In all conditions, the Vipi Dent Plus teeth showed higher bond strength to Lucitone and Vipi Cril resins when compared to Biolux teeth (P < 0.003). All specimens’ failure modes were cohesive. Conclusions: The SBS of acrylic teeth to denture base resins was not generally influenced by immersion in the tested staining beverages. PMID:27621547

  12. Inflammatory papillary hyperplasia: A systematic review

    PubMed Central

    Gual-Vaqués, Patricia; Jané-Salas, Enric; Egido-Moreno, Sonia; Ayuso-Montero, Raúl; Marí-Roig, Antoni

    2017-01-01

    Introduction Inflammatory papillary hyperplasia (IPH) is a benign lesion of the palatal mucosa. It is usually found in denture-wearers but also has been reported in patients without a history of use of a maxillary prosthesis use. Objetives The aim of this study is to review the literature to assess the prevalence of denture stomatitis and inflammatory papillary hyperplasia and the etiological factors associated. Material and Methods A search was carried out in PubMed (January 2005 to October 2015) with the key words “inflammatory papillary hyperplasia”, “denture stomatitis”, “granular stomatitis” and “Newton’s type III” The inclusion criteria were studies including at least a sample of 50 apparently healthy patients, articles published from 2005 to 2015 written in English. The exclusion criteria were reviews and non-human studies. Results Out of the 190 studies obtained initially from the search 16 articles were selected to be included in our systematic review. The prevalence of denture stomatitis was 29.56% and 4.44% for IPH. We found 5 cases of denture stomatitis among non-denture-wearer individuals. All IPH cases were associated with the use of prosthesis. Smoking and continued use of ill-fitting dentures turned out to be the most frequent risk factors for developing IPH. Conclusions IPH is a rare oral lesion and its pathogenesis still remains unclear. Its presentation among non-denture-wearers is extremely unusual. Key words:Inflammatory papillary hyperplasia, denture stomatitis, prevalence, granular stomatitis, Newton’s type III stomatitis. PMID:27918740

  13. Color stability of different denture teeth materials: an in vitro study.

    PubMed

    Mutlu-Sagesen, L; Ergün, G; Ozkan, Y; Bek, B

    2001-09-01

    The aim of this in vitro study was to compare the color stability of commercially available porcelain, reinforced acrylic, and conventional acrylic denture teeth materials used in removable prostheses. Two brands of porcelain (Unilux-Enta Lactona-Holland and Vivoperl-Ivoclar-Liechtenstein), 2 brands of reinforced acrylic (Optodent-Bayer-Germany and Ivolek-Ivoclar-Liechtenstein), and 2 brands of conventional acrylic (Isodent-Güney Diş Deposu-Turkey and Samed-Turkey), were made, for a total of 6 different denture teeth groups. Denture teeth were subjected to 3 staining solutions (filtered coffee, tea, and cola) and distilled water. From each group of denture teeth, 4 sets of maxillary anterior denture teeth were immersed in each of the 4 solutions. The color values of denture teeth were measured colorimetrically with the Gardner XL 20 Tristimulus Colorimeter (Gardner Lab. Inc., Bethesda, Maryland, USA). Color changes were characterized in the CIEL*a*b* color space. Color change values were determined after 1 day, 1 week, 2 weeks, and 4 weeks. The color difference values were calculated and then evaluated by two-way ANOVA statistically. The filtered coffee solution was found to be more chromogenic than the other 2 staining solutions, while porcelain denture teeth materials were more color stable. Assuming the color change of deltaE* < 1.0 as a discernible limit and deltaE* = 3.3 as an acceptable value, the filtered coffee, tea, and cola had slight staining effects on all 6 groups of denture teeth.

  14. Overlay removable denture for treatment of worn teeth.

    PubMed

    Beyth, Nurit; Tamari, Israel; Buller Sharon, Anat

    2014-01-01

    Rehabilitation of partially edentulous patients with excessively worn dentitions can be challenging. Factors including medical history as well as the cost of the treatment and patient wishes for simpler approaches must be considered. This manuscript describes the use of an overlay partial denture to treat patients with excessive wear of the maxillary teeth. We describe a technique to restore severely worn teeth using heat-cured acrylic as part of a partial or full denture. Minimal preparations of the teeth are required, and the restoration provides protection from further wear, and stabilizes the occlusion. This solution was functionally and esthetically suitable to the patients. The technique can be used in medically complex patients where extractions are contraindicated, such as post radiation therapy or bisphosphonate treatment. © 2014 Special Care Dentistry Association and Wiley Periodicals, Inc.

  15. Oral mucosal lesions in denture wearers.

    PubMed

    Jainkittivong, Aree; Aneksuk, Vilaiwan; Langlais, Robert P

    2010-03-01

    To determine the prevalence of oral mucosal lesions (OMLs) and denture-related mucosal lesions (DMLs) in denture wearers and to co-relate the prevalence with age, gender, type of denture and any systemic conditions. Dental records of 380 denture wearers were retrospectively reviewed for OMLs and DMLs. We found 45% of the denture wearers had DMLs and 60.8% had OMLs not related to denture wearing. Although the prevalence of DMLs was higher in complete denture wearers than in partial denture wearers (49% vs. 42.2%), this difference was not significant. The most common DMLs were traumatic ulcer (19.5%) and denture-induced stomatitis (18.1%). When analysed by type, traumatic ulcer, denture hyperplasia, frictional keratosis and candidiasis were more common in complete denture wearers, whereas denture-induced stomatitis was more common in partial denture wearers. Frictional keratosis was more common in men than in women. The prevalence of OMLs not related to denture wearing was higher in complete denture wearers than in partial denture wearers, and the most common OML was fissured tongue (27.6%). No association between DMLs and systemic conditions or xerostomic drugs was noted. No differences in the prevalence of DMLs in association with denture type were found. The prevalence of OMLs not related to denture wearing was higher in complete denture wearers than in partial denture wearers. This difference was affected by age, and the data were similar to the findings observed in the elderly.

  16. Influence of psychological factors on the acceptance of complete dentures.

    PubMed

    al Quran, F; Clifford, T; Cooper, C; Lamey, P J

    2001-07-01

    To assess the influence of psychological factors on the acceptance of complete dentures in a population wearing dentures judged to be clinically satisfactory. Subjects were asked to complete personality profiles and also to rate their dentures using a denture satisfaction questionnaire. The survey was conducted in the prosthetics clinic of a teaching hospital. Patients were selected from those who had new complete dentures constructed in the department within the previous two years. The personality inventory was a self-administered questionnaire comprising 240 items covering the five domains of personality. Denture satisfaction was scored on a nine item scale with four Likert type responses to each. A group of 16% consistently complained about their dentures. Statistical analysis showed that personality factors especially Neuroticism had a significant relationship with denture satisfaction. Psychological factors significantly influence denture satisfaction and profiles may provide useful in predicting potential difficult denture wearers.

  17. Managing the maxillary partially edentulous patient with extensive anterior tooth loss and advanced periodontal disease using a removable partial denture: a clinical report.

    PubMed

    Ma, Polly S; Brudvik, James S

    2008-10-01

    The treatment modality, a continuous occlusal rest removable partial denture, not only restored missing teeth but also stabilized the remaining dentition in a patient with advanced periodontal attachment loss. By engaging the guiding planes at the mesial surfaces of the abutments anteriorly and also the distal surfaces of the abutments posteriorly, the remaining teeth, with varying amounts of mobility, were splinted together by the framework. This conservative treatment option allows flexibility for easy repair during the life span of the prosthesis.

  18. Patient preference and satisfaction with implant-supported mandibular overdentures retained with ball or locator attachments: a crossover clinical trial.

    PubMed

    Krennmair, Gerald; Seemann, Rudolf; Fazekas, Andres; Ewers, Rolf; Piehslinger, Eva

    2012-01-01

    To determine patient satisfaction and preference for implant-supported mandibular overdentures (IOD) retained with ball or Locator attachments. In addition, peri-implant conditions and prosthodontic maintenance efforts for the final attachments were evaluated after 1 year of function. In this crossover clinical trial, 20 edentulous patients were recruited to receive two mandibular implants in the canine region and were provided with implant-retained mandibular overdentures and new complete maxillary dentures. Implant-retained mandibular overdentures were stabilized with either ball attachments or Locator attachments, in random order. After 3 months of function, the attachments in the existing denture were changed. Questionnaires on satisfaction/complaints with the prostheses were administered at baseline (with the old dentures) and after 3 months of function with each attachment, thus providing for an intraindividual comparison. The decision for the final attachment chosen was based on the patient's preference. For the definitive attachment, peri-implant conditions (peri-implant marginal bone resorption, pocket depth, and Plaque Index, Gingival Index, and Bleeding Index) as well as prosthodontic maintenance efforts and satisfaction score were evaluated after an insertion period of 1 year. Nineteen (95%) patients completed the study (1 dropout). Patient satisfaction improved significantly (P<.05) from baseline (old dentures) to the new prostheses retained with each of the two attachment types for all domains of satisfaction. However, there were no differences between ball or Locator attachment for any items of satisfaction evaluated and neither attachment had a significant patient preference. No differences for peri-implant parameters or for patient satisfaction were noted between the definitive attachments (ball, n=10; Locator, n=9) after 1 year. Although the overall incidence rate of prosthodontic maintenance did not significantly differ between both retention modalities, the Locator attachment required more postinsertion aftercare (activation of retention) than the ball anchors.

  19. Treatment planning: implant-supported partial overdentures.

    PubMed

    Chee, Winston W L

    2005-04-01

    When multiple anterior teeth are missing, many options of replacement are available. Traditionally, the choice was between a fixed or removable prostheses. Today, with the predictability of dental implants, the options of tooth replacement range from removable partial dentures to implant-supported fixed prostheses. The choice of which restoration that will best provide occlusion and esthetics depends on multiple factors including the number and location of missing teeth, the residual ridge form in relation to the replacement teeth, the relationship of the maxillary and mandibular anterior teeth, the condition of teeth adjacent to the edentulous span, the amount of bone available for implant placement, the patients "smile line" and display of teeth, lip support, and financial constraints. When there is minimal loss of the ridge contour, restorations that emerge from the ridge are the most functional and esthetic restorations, adhesive-type fixed partial dentures, conventional fixed partial dentures, and implant-supported restorations can be indicated with the choice of restoration dependent on a risk benefit and cost benefit analysis. When there is a loss of ridge contour due to residual ridge resorption or trauma, the decision becomes more complex as not only does the tooth structure need to be replaced, the ridge form also has to be replaced. (Figures 1 and 2). This can be assessed clinically as illustrated by Figures 1 and 2 where a dis crepancy in arch form and ridge form in relation to the adjacent teeth and/or opposing arch can be observed. Other considerations are lip support and display of the teeth when smiling. This article presents a case and rationale for implant-supported par tial overdentures. Many authors have written on the merits of com plete overdentures. The complete overdenture has proven to be an improvement over conventional complete prostheses with respect to chewing efficiency, patient comfort and satisfaction. In partial edentulism, the implant-supported overdenture has several advantages, some in common with a removable partial denture.

  20. Alveolar nerve repositioning with rescue implants for management of previous treatment. A clinical report.

    PubMed

    Amet, Edward M; Uehlein, Chris

    2013-12-01

    The goal of modern implant dentistry is to return patients to oral health in a rapid and predictable fashion, following a diagnostically driven treatment plan. If only a limited number of implants can be placed, or some fail and the prosthetic phase of implant dentistry is chosen to complete the patient's treatment, the final outcome may result in partial patient satisfaction and is commonly referred to as a "compromise." Previous All-on-4 implant treatment for the patient presented here resulted in a compromise, with an inadequate support system for the mandibular prosthesis and a maxillary complete denture with poor esthetics. The patient was unable to function adequately and also was disappointed with the resulting appearance. Correction of the compromised treatment consisted of bilateral inferior alveolar nerve elevation and repositioning without bone removal for lateral transposition, to gain room for rescue implants for a totally implant-supported and stabilized prosthesis. Treatment time to return the patient to satisfactory comfort, function, facial esthetics, and speech was approximately 2 weeks. The definitive mandibular prosthesis was designed for total implant support and stability with patient retrievability. Adequate space between the mandibular bar system and the soft tissue created a high water bridge effect for self-cleansing. Following a short interim mandibular healing period, the maxillary sinuses were bilaterally grafted to compensate for bone inadequacies and deficiencies for future maxillary implant reconstruction. © 2013 by the American College of Prosthodontists.

  1. Do Implant Overdentures Improve Dietary Intake? A Randomized Clinical Trial

    PubMed Central

    Hamdan, N.M.; Gray-Donald, K.; Awad, M.A.; Johnson-Down, L.; Wollin, S.; Feine, J.S.

    2013-01-01

    People wearing mandibular two-implant overdentures (IOD) chew food with less difficulty than those wearing conventional complete dentures (CD). However, there is still controversy over whether or not this results in better dietary intake. In this randomized clinical trials (RCT), the amounts of total dietary fiber (TDF), macronutrients, 9 micronutrients, and energy in diets consumed by persons with IOD and CD were compared. Male and female edentate patients ≥ 65 yrs (n = 255) were randomly divided into 2 groups and assigned to receive a maxillary CD and either a mandibular IOD or a CD. One year following prosthesis delivery, 217 participants (CD = 114, IOD = 103) reported the food and quantities they consumed to a registered dietician through a standard 24-hour dietary recall method. The mean and median values of TDF, macro- and micronutrients, and energy consumed by both groups were calculated and compared analytically. No significant between-group differences were found (ps > .05). Despite quality-of-life benefits from IODs, this adequately powered study reveals no evidence of nutritional advantages for independently living medically healthy edentate elders wearing two-implant mandibular overdentures over those wearing conventional complete dentures in their dietary intake at one year following prosthesis delivery (International Clinical Trials ISRCTN24273915). PMID:24158335

  2. Alkaline Peroxides Versus Sodium Hypochlorite for Removing Denture Biofilm: a Crossover Randomized Trial.

    PubMed

    Peracini, Amanda; Regis, Rômulo Rocha; Souza, Raphael Freitas de; Pagnano, Valéria Oliveira; Silva, Cláudia Helena Lovato da; Paranhos, Helena de Freitas Oliveira

    2016-01-01

    This study evaluated the efficacy of cleanser solutions on denture biofilm removal by a crossover randomized clinical trial. Thirty two edentulous patients were instructed to brush their dentures (specific brush and liquid soap) three times a day (after breakfast, lunch and dinner) and to soak them (≥ 8 h) in: (C) control -water; (AP): alkaline peroxide; or (SH) 0.5% sodium hypochlorite. Each solution was used for 21 days (three cycles of 7 days). At the end of each cycle, the inner surfaces of maxillary dentures were disclosed (1% neutral red) and photographed (HX1 - Sony). Areas (total and stained biofilm) were measured (Image Tool software) and the percentage of biofilm calculated as the ratio between the area of the biofilm multiplied by 100 and total surface area of the internal base of the denture. Data were compared by means of generalized estimating equation (α=5%) and multiple comparisons (Bonferroni; α=1.67%). Immersion in SH reduced biofilm (%) (8.3 ± 13.3B) compared to C (18.2 ± 14.9A) and AP (18.2 ± 16.6A). The 0.5% sodium hypochlorite solution was the most efficacious for biofilm removal. Alkaline peroxides may not lead to further biofilm removal in patients with adequate denture maintenance habits.

  3. The impact of kiddy dentures on maxillary arch growth.

    PubMed

    Shih, Wen-Yu; Wu, Fu-Ya

    2016-09-01

    Kiddy dentures are used to restore the self-confidence, chewing function, and pronunciation of children or when a care provider is concerned about the loss of incisor teeth. However, most studies to date have investigated normal dental arch development, and only a few have explored the effect of kiddy dentures on upper arch development. Fourteen Taiwanese children (7 male and 7 female) who were wearing kiddy dentures due to the loss of their upper anterior teeth were enrolled in this study. Inclusion criteria were the premature loss of maxillary incisors, the patient wearing kiddy dentures with both upper primary first molars as abutments, and the patient having complete records allowing a full longitudinal clinical follow-up. Dental casts were obtained immediately (T1), at 6 months (T2), and at 12 months (T3) after delivery of the kiddy dentures. The measured parameters included intercanine width (ICW, C1 to C2), interfirst molar width (IDW, D1 to D2), and intersecond molar width (IEW, E1 to E2). All the measurements were performed by one experienced examiner using a vernier caliper. The mean ages of the enrolled children for the periods T1, T2, and T3 were 43.8 ± 8.3 months, 50.6 ± 8.5 months, and 56.7 ± 8.4 months, respectively. There was no significant difference in gender when ICW, IDW, and IEW were compared. The mean changes in ICW values were 23.6 ± 6.2 mm, 24.2 ± 5.9 mm, and 24.6 ± 6.4 mm for T1, T2, and T3, respectively. There were statistically significant differences between T1 and T2, T2 and T3, and T1 and T3 for ICW (p < 0.05). The mean changes in IDW were 25.7 ± 8.4 mm, 25.8 ± 9.0 mm, and 25.8 ± 9.1 mm for T1, T2, and T3, respectively. There was no statistically significant difference between T1 and T2, T2 and T3, and T1 and T3. The mean changes in IEW were 30.6 ± 10.1 mm, 31.2 ± 8.8 mm, and 31.3 ± 8.2 mm for T1, T2, and T3, respectively. There was statistical significance between T1 and T2 or T1 and T3 for IDW (p < 0.05). Kiddy dentures do interfere with the transverse growth of the dental arch over the abutment tooth area during a 1-year follow-up period. However the teeth adjacent to the confined abutments still show transverse growth. Copyright © 2016. Published by Elsevier Taiwan LLC.

  4. Elderly complete denture wearers: a social approach to tooth loss.

    PubMed

    Papadaki, Eftychia; Anastassiadou, Vassiliki

    2012-06-01

    To correlate emotional reactions to tooth loss with denture satisfaction attributes in elderly complete denture wearers. Total tooth loss is a serious life event, and poor oral health has an impact on daily life. Edentulism treated by rehabilitation with dentures can have a positive effect on patients' self-image and social behaviour. A group of 80 edentulous subjects undergoing routine prosthetic care in a Greek Department of Prosthetic Dentistry were interviewed using two structured questionnaires. The first questionnaire explored reactions to tooth loss, whereas the second measured their subjective experience of complete dentures. The responses to both questionnaires were compared using the statistical package SPSS v.17. The results showed significant correlation between aspects of tooth loss experience and complete denture satisfaction. Despite the fact that a substantial proportion of patients were satisfied with their complete dentures, some patients experienced increased social and psychological problems related to their edentulousness and the wearing of complete dentures. The aesthetic and functional aspects of complete dentures affected both patients' social behaviour and self-confidence. Total tooth loss was not only reflected in patient's social behaviour and self-image, but it had a complex and multifaceted impact on satisfaction from complete dentures. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  5. Epidemiological Data and Survival Rate of Removable Partial Dentures

    PubMed Central

    Moreno, Amália; Haddad, Marcela Filié; Rocha, Eduardo Passos; Assunção, Wirley Gonçalves; Filho, Humberto Gennari; Santos, Emerson Gomes Dos; Sonego, Mariana Vilela; Santos, Daniela Micheline Dos

    2016-01-01

    Introduction The use of removable partial denture (RPD) is considered as low-cost and common treatment option to rehabilitate edentulous areas. Aim This study aimed to investigate the epidemiological data of patients rehabilitated with removable partial denture (RPD) in order to assess treatment survival rate and failures. Materials and Methods Epidemiological data and medical records of patients treated with RPD between 2007 and 2012 at the RPD discipline of a Brazilian University (Aracatuba Dental School- UNESP) were evaluated as well as dental records of patients who underwent RPD treatments (fabrication or repairs) between 2000 and 2010. Factors such as gender, age, presence of systemic disease, main complaint, edentulous arch, period and cause of denture replacement and the prosthesis characteristics were recorded. The chi-square test was used to assess the differences between the variables and the Kaplan Meyer to assess the survival of the RPDs evaluated. Results A total of 324 maxillary RPD and 432 mandibular RPD were fabricated. Most of the patients were women aging 41 to 60-year-old. The number of mandibular RPD Kennedy class I (26%) was statistically higher for the maxillary arch (p<.05). There was no association between main complaint to gender or the presence of systemic disease. The lingual plate was the most common major connector used in the mandible (32%). The main reason for altering the design of replaced RPDs were changes during treatment plan. Conclusion The number of patients who require RPD is large; most of RPDs are Kennedy Class I. A good treatment plan is very important for achieving a positive treatment outcome, and it is strictly related to the survival rate. PMID:27437367

  6. Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures

    PubMed Central

    Al-mejrad, Lamya A.; Albarrag, Ahmed M.

    2017-01-01

    PURPOSE The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. MATERIALS AND METHODS Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. RESULTS There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure (P<.05). CONCLUSION The CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures. PMID:29142649

  7. Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures.

    PubMed

    Al-Fouzan, Afnan F; Al-Mejrad, Lamya A; Albarrag, Ahmed M

    2017-10-01

    The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure ( P <.05). The CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures.

  8. Complete denture services: clinical technique, lab costs, manpower, and reimbursement. One-year review.

    PubMed

    Ewoldsen, Nels

    2011-01-01

    Complete denture services at comprehensive care public health clinics are not common in part because of clinician concerns regarding outcomes. Educational debt forgiveness has attracted recent dental graduates to public health dentistry; however, not all recent graduates receive denture education experiences necessary to attain proficiency. While fundamental patient assessment and denture construction are taught, psychological assessment and communication with denture patients requires experience. A thorough understanding of occlusion, phonetics, esthetics and laboratory steps is also necessary. Expecting recent dental graduates to become proficient providing complete dentures at minimal reimbursement levels, with no mentorship or on-site laboratory support, is unrealistic. Public health dental clinics operate at full capacity performing emergency, preventive and restorative procedures. Complete dentures come with a laboratory fee approximately one-half the total reimbursement, meaning a remake drops clinic revenue to zero while doubling expenses. It is understandable that full schedules, marginal reimbursement, unpredictability and the risk of an occasional failure block clinician interest in providing denture services. This one-year report of services describes a three-appointment complete denture technique offering improved patient and laboratory communication, reduced chair time and controlled cost, resulting in high-quality complete dentures.

  9. Virtual surgical planning for treatment of severe mandibular retrognathia with collapsed occlusion using contemporary surgical and prosthodontic protocols.

    PubMed

    Dhima, Matilda; Salinas, Thomas J; Rieck, Kevin L

    2013-11-01

    To meet functional and esthetic needs in an older adult for treatment of complex skeletal and dentoalveolar deformities using contemporary surgical and prosthodontic protocols. An older adult with dentoalveolar complex and skeletal deformity (mandibular retrognathia) was treated by a combination of virtual planning and current surgical and prosthodontic protocols. Treatment planning steps and sequencing are presented. Skeletal, soft tissue, and dental harmonies were attained without biological or mechanical complications. Definitive oral rehabilitation was completed with a maxillary complete denture and a mandibular metal ceramic fixed implant-retained prosthesis. A surgical and prosthodontic team approach in combination with technologic advances can predictably optimize esthetic and functional outcomes for patients with complex skeletal and dentoalveolar deformities. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Prosthodontic management of a patient with ectodermal dysplasia.

    PubMed

    Nandini, Yamini

    2013-12-01

    Ectodermal dysplasia is a rare congenital disease that affects the ectodermal structures. It is characterized by hypotrichosis, hypohidrosis and hypodontia. A 14-year-old boy with ectodermal dysplasia presenting with oligodontia and marked resorption of the maxillary and mandibular alveolar ridges is reported. Prosthetic rehabilitation in the form of a maxillary and mandibular partial denture was made with metal crowns on existing lower teeth to achieve appropriate vertical dimension. Significant improvement in speech, masticatory function and facial esthetics was achieved. Removable prosthodontics can provide an acceptable solution to esthetic, functional and psychological rehabilitation in patients with ectodermal dysplasia.

  11. An economic evaluation of maxillary implant overdentures based on six vs. four implants.

    PubMed

    Listl, Stefan; Fischer, Leonhard; Giannakopoulos, Nikolaos Nikitas

    2014-08-18

    The purpose of the present study was to assess the value for money achieved by bar-retained implant overdentures based on six implants compared with four implants as treatment alternatives for the edentulous maxilla. A Markov decision tree model was constructed and populated with parameter estimates for implant and denture failure as well as patient-centred health outcomes as available from recent literature. The decision scenario was modelled within a ten year time horizon and relied on cost reimbursement regulations of the German health care system. The cost-effectiveness threshold was identified above which the six-implant solution is preferable over the four-implant solution. Uncertainties regarding input parameters were incorporated via one-way and probabilistic sensitivity analysis based on Monte-Carlo simulation. Within a base case scenario of average treatment complexity, the cost-effectiveness threshold was identified to be 17,564 € per year of denture satisfaction gained above of which the alternative with six implants is preferable over treatment including four implants. Sensitivity analysis yielded that, depending on the specification of model input parameters such as patients' denture satisfaction, the respective cost-effectiveness threshold varies substantially. The results of the present study suggest that bar-retained maxillary overdentures based on six implants provide better patient satisfaction than bar-retained overdentures based on four implants but are considerably more expensive. Final judgements about value for money require more comprehensive clinical evidence including patient-centred health outcomes.

  12. An economic evaluation of maxillary implant overdentures based on six vs. four implants

    PubMed Central

    2014-01-01

    Background The purpose of the present study was to assess the value for money achieved by bar-retained implant overdentures based on six implants compared with four implants as treatment alternatives for the edentulous maxilla. Methods A Markov decision tree model was constructed and populated with parameter estimates for implant and denture failure as well as patient-centred health outcomes as available from recent literature. The decision scenario was modelled within a ten year time horizon and relied on cost reimbursement regulations of the German health care system. The cost-effectiveness threshold was identified above which the six-implant solution is preferable over the four-implant solution. Uncertainties regarding input parameters were incorporated via one-way and probabilistic sensitivity analysis based on Monte-Carlo simulation. Results Within a base case scenario of average treatment complexity, the cost-effectiveness threshold was identified to be 17,564 € per year of denture satisfaction gained above of which the alternative with six implants is preferable over treatment including four implants. Sensitivity analysis yielded that, depending on the specification of model input parameters such as patients’ denture satisfaction, the respective cost-effectiveness threshold varies substantially. Conclusions The results of the present study suggest that bar-retained maxillary overdentures based on six implants provide better patient satisfaction than bar-retained overdentures based on four implants but are considerably more expensive. Final judgements about value for money require more comprehensive clinical evidence including patient-centred health outcomes. PMID:25135370

  13. Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis.

    PubMed

    Lima, Ana Paula Barbosa; Vitti, Rafael Pino; Amaral, Marina; Neves, Ana Christina Claro; da Silva Concilio, Lais Regiane

    2018-04-01

    This study evaluated the dimensional stability of a complete-arch prosthesis processed by conventional method in water bath or microwave energy and polymerized by two different curing cycles. Forty maxillary complete-arch prostheses were randomly divided into four groups (n = 10): MW1 - acrylic resin cured by one microwave cycle; MW2 - acrylic resin cured by two microwave cycles: WB1 - conventional acrylic resin polymerized using one curing cycle in a water bath; WB2 - conventional acrylic resin polymerized using two curing cycles in a water bath. For evaluation of dimensional stability, occlusal vertical dimension (OVD) and area of contact points were measured in two different measurement times: before and after the polymerization method. A digital caliper was used for OVD measurement. Occlusal contact registration strips were used between maxillary and mandibular dentures to measure the contact points. The images were measured using the software IpWin32, and the differences before and after the polymerization methods were calculated. The data were statistically analyzed using the one-way ANOVA and Tukey test (α = .05). he results demonstrated significant statistical differences for OVD between different measurement times for all groups. MW1 presented the highest OVD values, while WB2 had the lowest OVD values ( P <.05). No statistical differences were found for area of contact points among the groups ( P =.7150). The conventional acrylic resin polymerized using two curing cycles in a water bath led to less difference in OVD of complete-arch prosthesis.

  14. Dental implants as strategic supplementary abutments for implant-tooth-supported telescopic crown-retained maxillary dentures: a retrospective follow-up study for up to 9 years.

    PubMed

    Krennmair, Gerald; Krainhöfner, Martin; Waldenberger, Otmar; Piehslinger, Eva

    2007-01-01

    The aim of this retrospective study was to present the results of implants and natural teeth used as combined abutments to support maxillary telescopic prostheses. Between 1997 and 2004, 22 patients with residual maxillary teeth underwent prosthodontic rehabilitation with supplementary implant placement of implant-tooth-supported telescopic prostheses. A total of 60 supplementary implants (mean: 2.9 implants; SD: 1.6; range: 1 to 5 per patient) were placed in strategic position and connected with 48 natural abutment teeth (mean: 2.2 teeth; SD: 0.9; range: 1 to 4 per patient) using telescopic crowns. The follow-up registration included implant and natural tooth survival rates and peri-implant and periodontal parameters, along with prosthodontic maintenance. Natural tooth abutments were additionally followed to compare their periodontal parameters at baseline to the follow-up examination. After a mean of 38 months (12 to 108 months) no implants or natural tooth abutments were lost (survival rate: 100%). There was no fracture, endodontic treatment, loss, or intrusion of natural teeth used for telescopic abutments. Implant abutments showed high stability and excellent periimplant soft tissue conditions. Natural tooth abutments used for double crowns also showed uneventful progress. A low rate of prosthodontic maintenance was seen, with implant screw abutment loosening as the most severe complication (3 of 60 implants; 5%). On the basis of this retrospective clinical review, the following conclusions were drawn: (1) successful function over a prolonged period and a minor complication rate of implant-tooth-supported telescopic maxillary dentures may be anticipated, and (2) the great variety of treatment modalities offered by tooth-implant support for telescopic prostheses appears to be useful as a treatment option for the maxilla in elderly patients.

  15. A Clinical Study to Examine the Effect of Complete Denture on Head Posture/Craniovertical Angle.

    PubMed

    Khare, Amit; Nandeeshwar, D B; Sangur, Rajashekar; Makkar, Sumit; Khare, Pooja; Chitumalla, Rajkiran; Prasad, Renuka

    2016-04-01

    Edentulous patients show some significant changes in ridge relationship caused by resorption of alveolar ridge. The changes are characterized by an upward rotation of mandible, increase in mandibular prognathism that ultimately results in change of natural head posture. This clinical study was planned to know the effect of complete denture on head posture in different age groups of Indian completely edentulous population, after placement of complete denture at various time intervals. The sample consisted of completely edentulous patients without previous experience of the dentures. They were divided into 2 age groups: Group A (45-60) and Group B (61-75). During placement of complete denture craniovertical angle was measured with the help of custom made ruler protector device. Readings were taken before denture placement, immediately after denture placement, 30 minutes, 24 hours and 30 days after dentures placement. The results of this study indicated that in most of the patients (90%) despite their age, change in head posture (extension) occurred immediately after the denture placement. Thereafter reading remains same for measurement at 30 minutes and 24 hours of denture placement. However after 30 days, observation revealed that all the patients showed reduced craniovertical angle (flexion). Even though the values of craniovertical angle remain higher than its baseline in both groups, significant changes were noticed only in Group A. Findings revealed that head posture was significantly altered by the placement of dentures in completely edentulous patients. Within the time interval of 30 minutes and 24 hours extension of head posture remained constant with slight variation. Although after 30 days, changes remained significant for group 'A', but no significant changes were observed in the subjects of group 'B'.

  16. Maxillary rehabilitation using fixed and removable partial dentures with attachments: a clinical report.

    PubMed

    dos Santos Nunes Reis, José Maurício; da Cruz Perez, Luciano Elias; Alfenas, Bruna Fernandes Moreira; de Oliveira Abi-Rached, Filipe; Filho, João Neudenir Arioli

    2014-01-01

    Despite requiring dental crown preparation and possible root canal treatment, besides the difficulty of clinical and laboratory repairs, and financial burden, the association between fixed (FPD) and removable partial dentures (RPD) by means of attachments is an important alternative for oral rehabilitation, particularly when the use of dental implants and FPDs is limited or not indicated. Among the advantages of attachment-retained RPDs are the improvements in esthetics and biomechanics, as well as correction of the buccal arrangement of anterior teeth in Kennedy Class III partially edentulous arches. This article describes the treatment sequence and technique for the use of attachments in therapy combining FPD/RPD. © 2013 by the American College of Prosthodontists.

  17. IN VITRO WEAR RESISTANCE OF THREE TYPES OF POLYMETHYL METHACRYLATE DENTURE TEETH

    PubMed Central

    Reis, Katia Rodrigues; Bonfante, Gerson; Pegoraro, Luiz Fernando; Conti, Paulo Cesar Rodrigues; de Oliveira, Pedro Cesar Garcia; Kaizer, Osvaldo Bazzan

    2008-01-01

    The wear resistance of denture teeth is important to the longevity of removable prostheses of edentulous patients. The ability of denture teeth to maintain a stable occlusal relationship over time may be influenced by this property. The purpose of this in vitro study was to evaluate the wear resistance of polymethyl methacrylate (PMMA) denture teeth based on their chemical composition when opposed by a ceramic antagonist. The maxillary canines (n=10) of 3 PMMA denture teeth (Trubyte Biotone, cross-linked PMMA; Trilux, highly cross-linked IPN (interpenetrating polymer network)-PMMA; and Vivodent, highly cross-linked PMMA) were secured in an in vitro 2-body wear-testing apparatus that produced sliding contact of the specimens (4.5 cycles/s, sliding distance of 20 mm, under 37°C running water) against glazed or airborne particle abraded ceramic. Wear resistance was measured as height loss (mm) under 300 g (sliding force) after 100,000 cycles, using a digital measuring microscope. Mean values were analyzed by 2-way ANOVA and Tukey's test (α=0.05). The wear of Trubyte Biotone (0.93 ± 0.14 mm) was significantly higher than that of both other types of teeth tested against abraded ceramic (p<0.05). The Vivodent tooth (0.64 ± 0.17 mm) exhibited the best wear resistance among the denture teeth tested against airborne particle abraded ceramic. There were no statistically significant differences (p>0.05) in wear among the 3 denture teeth evaluated against glazed ceramic. Trilux and Vivodent teeth tested against either glazed or airborne particle abraded ceramic did not differ significantly from each other (p<0.05). All teeth showed significantly more wear against airborne particle abraded ceramic than against glazed ceramic (p<0.05). In conclusion, the three types of PMMA denture teeth presented significantly different wear resistance against the abraded ceramic. The high-strength PMMA denture teeth were more wear-resistant than the conventional PMMA denture tooth. PMID:19089214

  18. Cephalometric Evaluation of the Effect of Complete Dentures on Retropharyngeal Space and Its Effect on Spirometric Values in Altered Vertical Dimension

    PubMed Central

    Gupta, Prachi; Thombare, Ram; Pakhan, A. J.; Singhal, Sameer

    2011-01-01

    Role of complete dentures in reducing apnea-hypoapnea index in edentulous obstructive sleep apnea patient has shown promising results in previous studies. This study was undertaken to ascertain the role of complete denture and complete denture with slight increase in vertical dimension using custom made occlussal jig, on retropharyngeal space, posterior airway space, pharyngeal depth, and spirometric readings in comparison with those in edentulous group. Significant changes were observed in both intervention groups and thus, paving the way for doing further research for the consideration of using complete denture with modifications as an oral appliance in edentulous obstructive sleep apnea patient. PMID:21991477

  19. Satisfaction in complete denture wearers with and without adhesives: A randomized, crossover, double-blind clinical trial

    PubMed Central

    Torres-Sánchez, Carlos; Montoya-Salazar, Vanessa; Gutierrez-Pérez, Jose-Luis; Jimenez-Castellanos, Emilio

    2018-01-01

    Background The purpose of this study was to compare the satisfaction of patients regarding retention, stability and accumulation of particles with a randomized, double-blind crossed method in users with complete dentures with and without adhesive. Material and Methods Seventeen edentulous individuals were randomized and received new upper and lower complete dentures. After a period of adaptation, they participated in some masticatory tests and clinical revisions, after use the protheses with and without the use of two denture adhesives: Adhesive A (Fittydent, Fittydent International GmbH) and adhesive B (Corega, GlaxoSmithKline) at 0, 7 and 14 days. Satisfaction was measured immediately after each test through a survey using a VAS scale (0-10) and data were analyzed with McNemar’s test with Bonferroni correction. Results The results showed significant differences (p<.01) between the study groups with adhesive A - B and the group without adhesive, but no significant differences were found between the two stickers for any of the variables studied. Conclusions Complete denture adhesives significantly improved the satisfaction of patients because a better retention, stability and less accumulation of particles of the food substitute between the denture and the mucosa is obtained compared with non-use of complete denture adhesives. Key words:Complete dentures, patient satisfaction, denture adhesives, clinical trials. PMID:29946414

  20. Evaluation of the utility of cephalometric parameters in constructing complete denture. Part I: placement of posterior teeth.

    PubMed

    Bassi, F; Deregibus, A; Previgliano, V; Bracco, P; Preti, G

    2001-03-01

    Various types of parameters, including cephalometric ones, have been used in the construction of complete denture. This study aimed to evaluate the utility of cephalometric parameters for this purpose. The position of the posterior teeth in a group of 42 edentulous patients, successfully rehabilitated with complete denture according to clinical parameters, was evaluated by cephalometrics. The following were determined: vertical dimension of occlusion (VDO); orientation of the occlusal plane; and subdivision of the denture space. The cephalometric parameters do not correspond to the clinical positioning of the posterior teeth in successful rehabilitation with complete denture.

  1. Expectations and final evaluation of complete dentures by patients, dentist and dental technician.

    PubMed

    Marachlioglou, C R M Z; Dos Santos, J F F; Cunha, V P P; Marchini, Leonardo

    2010-07-01

    There is a poor association between the dentist's evaluation of denture quality and patients' satisfaction with their dentures. Possible differences between dental professionals and patients' expectations might help explain differences in outcome evaluations. This study compared scores given by a dentist, a dental technician and patients for their expectations before and their final evaluation after complete dentures treatment. Twenty completely edentulous patients, a prosthodontist and a dental technician provided scores for the expected aesthetic and functional results of their dentures based on a visual analogue scale at baseline. Post-treatment completion ratings were given after adjustments, by dentist and patients. The dental technician provided post-treatment completion ratings after completing the dentures. The patients had higher expectations than the dental technician and the dentist perceived for both aesthetic and function (P < 0.001). The patients also presented higher post-treatment completion ratings than the dental professionals perceived for final aesthetics (P = 0.016, Kendall's W = 0.207) and function (P = 0.002, Kendall's W = 0.303). Only the dentist presented a statistically significant difference between expectations (lower) and final (higher) outcomes for aesthetics (P = 0.017) and function (P = 0.003). There was no correlation between expectations and post-treatment completion ratings according to the patients' age. There was also no correlation between the patients' gender and expectation scores. Patients presented higher expectations regarding their dentures than dental professionals. The dentist believed that dentures would bring fewer benefits than patients did, but his perception of denture benefits post-treatment was significantly higher than his expectations.

  2. Two implants for all edentulous mandibles.

    PubMed

    Wright, P S

    2006-04-22

    Complete dentures have always been a poor substitute for natural teeth. Mandibular complete dentures frequently cause pain and discomfort, accelerated residual bone resorption, while failing to restore effective chewing. The provision of two implants to stabilise the mandibular complete denture can result in significant improvements.

  3. Correlation of masticatory muscle activity with masticatory ability in complete denture patients with canine guidance and balanced occlusion

    NASA Astrophysics Data System (ADS)

    Maxwell, D.; Odang, R. W.; Koesmaningati, H.

    2017-08-01

    Balanced occlusion is commonly used in complete denture occlusion scheme; however, canine guidance offers a simpler process and reduces alveolar ridge resorption. Correlative research of these two occlusion schemes is required. This study was done to analyze the correlation between masticatory muscle activity and masticatory ability of the subjects with canine guidance and balanced occlusion complete dentures. Ten denture wearers participated in this cross-over clinical trial, and five subjects were randomly selected to wear balanced occlusion followed by canine guidance complete dentures and vice versa. Electromyogram (EMG) activities of superficial masseter and anterior temporal muscles were measured and masticatory ability questionnaires were collected 30 days after the subjects wore each occlusal scheme. There were significant differences between the EMG activities of masticatory muscles in subjects who were given canine guidance and balanced occlusion complete dentures (p < 0.05). Subjects rated their masticatory ability as being significantly better when using canine guidance dentures (p = 0.046). There was a significant and strong correlation (p = 0.045; r = 0.642) between the EMG activity of anterior temporal muscles and masticatory ability when the subjects wore balanced occlusion dentures and between the EMG activity of superficial masseter muscles and masticatory ability (p = 0.043; r = 0.648) when wearing canine guidance dentures. Masticatory ability is better when using canine guidance dentures. There is a significant and strong correlation between masticatory muscle activity and masticatory ability.

  4. Cast titanium overlay denture for a geriatric patient with a reduced vertical dimension.

    PubMed

    Guttal, Satyabodh; Patil, Narendra P

    2005-12-01

    An older patient reporting to the dental surgery for his/her dental treatment is becoming a common occurrence. Improved oral hygiene has meant that teeth are retained for a longer time, along with the potential problems of attrition, decreased vertical dimension, temporomandibular joint discomfort/strain, and poor aesthetics. The case in question is that of a 65-year-old male patient who had severe attrition in the lower arch, temporomandibular joint pain and reduced vertical dimension. The maxillary arch had previously been restored with a fixed partial prosthesis. For restoration of the lower teeth, a removable cast titanium overlay denture was fabricated incorporating an increased vertical dimension. Porcelain facings were placed to restore the aesthetics of the anterior teeth. The titanium was cast in a semi-automatic electric arc, pressure type casting machine. A titanium overlay denture with porcelain facing on the anterior teeth may provide a means of restoring a patient's concerns regarding aesthetics and function.

  5. Effect of surface treatments on shear bond strength of denture teeth to denture base resins

    PubMed Central

    Bahrani, Farideh; Khaledi, Amir Ali Reza

    2014-01-01

    Background: Debonding of denture teeth from denture bases is the most common failure in removable dentures. The purpose of this study was to evaluate the effect of surface treatments on shear bond strength of denture teeth to heat-polymerized and autopolymerized denture base resins. Materials and Methods: In this experimental in vitro study, 60 maxillary central incisor acrylic teeth were divided into two groups. Group M was polymerized with heat-polymerized acrylic resin (Meliodent) by compression molding technique and group F was processed by autopolymerized acrylic resin (Futura Gen) by injection molding technique. Within each group, specimens were divided into three subgroups according to the teeth surface treatments (n = 10): (1) ground surface as the control group (M1 and F1), (2) ground surface combined with monomer application (M2 and F2), and (3) airborne particle abrasion by 50 μm Al2O3 (M3 and F3). The shear bond strengths of the specimens were tested by universal testing machine with crosshead speed of 5 mm/min. Data were analyzed by two-way analysis of variance (ANOVA) and Tukey's honestly significant difference (HSD) tests (P < 0.05). Results: The mean shear bond strengths of the studied groups were 96.40 ± 14.01, 124.70 ± 15.64, and 118 ± 16.38 N for M1, M2, and M3 and 87.90 ± 13.48, 117 ± 13.88, and 109.70 ± 13.78 N for F1, F2, and F3, respectively. The surface treatment of the denture teeth significantly affected their shear bond strengths to the both the denture base resins (P < 0.001). However, there were no significant differences between the groups treated by monomer or airborne particle abrasion (P = 0.29). The highest percentage of failure mode was mixed in Meliodent and adhesive in Futura Gen. Conclusion: Monomer application and airborne particle abrasion of the ridge lap area of the denture teeth improved their shear bond strengths to the denture base resins regardless of the type of polymerization. PMID:24688570

  6. Influence of the fast-processing technique on the number of the occlusal contacts and occlusal vertical dimension of complete dentures.

    PubMed

    Atashrazm, Parsa; Alavijeh, Leila Zamani; Afshar, Maryam Sadat Sadrzadeh

    2011-03-01

    Occlusal errors during acryl processing affect the retention and stability of complete dentures. The aim of the present study was to assess the influence of a short curing technique on the number of occlusal contacts and the occlusal vertical dimension (OVD) of complete dentures. Complete dentures were prepared. The number of occlusal contacts was recorded in centric relation (CR) using 60 µ articulation paper. The OVD was recorded with the waxed trial denture in place. Dentures were then invested and processed with compression molding and short cure water bath technique. The number of occlusal contacts was recorded again. The amount of pin opening was measured for all of the complete dentures on the articulator. Data were analyzed with paired t-test to determine the alterations. The mean number of occlusal contacts before and after processing was 10.9 ± 2.4 and 6.3 ± 3.1 respectively (4.7 ± 1.9 decrease; p < 0.001). A 2 mm mean increase in OVD was observed in 47.7% of the dentures with < 6 occlusal contact changes and 88.9% of the dentures with ≥ 6 occlusal contact changes (p < 0.003). A significant change in the number of occlusal contacts was associated with an OVD increased up to two times. The short curing technique seems to be related to the decreased occlusal contacts and increased OVD. CLINICAL SIGNIFICANCES: More time is needed to adjust the occlusal errors of this method, because it has a negative effect on the morphologic pattern of artificial teeth of complete dentures and thus should be used carefully.

  7. The importance of a two-step impression procedure for complete denture fabrication: a systematic review of the literature.

    PubMed

    Regis, R R; Alves, C C S; Rocha, S S M; Negreiros, W A; Freitas-Pontes, K M

    2016-10-01

    The literature has questioned the real need for some clinical and laboratory procedures considered essential for achieving better results for complete denture fabrication. The aim of this study was to review the current literature concerning the relevance of a two-step impression procedure to achieve better clinical results in fabricating conventional complete dentures. Through an electronic search strategy of the PubMed/MEDLINE database, randomised controlled clinical trials which compared complete denture fabrication in adults in which one or two steps of impressions occurred were identified. The selections were made by three independent reviewers. Among the 540 titles initially identified, four studies (seven published papers) reporting on 257 patients evaluating aspects such as oral health-related quality of life, patient satisfaction with dentures in use, masticatory performance and chewing ability, denture quality, direct and indirect costs were considered eligible. The quality of included studies was assessed according to the Cochrane guidelines. The clinical studies considered for this review suggest that a two-step impression procedure may not be mandatory for the success of conventional complete denture fabrication regarding a variety of clinical aspects of denture quality and patients' perceptions of the treatment. © 2016 John Wiley & Sons Ltd.

  8. Photogrammetry Impression Technique: A Case History Report.

    PubMed

    Sánchez-Monescillo, Andrés; Sánchez-Turrión, Andrés; Vellon-Domarco, Elena; Salinas-Goodier, Carmen; Prados-Frutos, Juan Carlos

    2016-01-01

    The aim of this report is to present photogrammetry as a reliable step in the fabrication of a full-arch immediate rehabilitation. A 59-year-old man attended the department seeking dental rehabilitation for the sequelae of severe oral health neglect. The mandibular teeth suffered from advanced periodontal disease and the patient wore a maxillary complete denture. An irreversible hydrocolloid impression of the mandibular arch was made, poured in stone, and digitally scanned to create the first stereolithography (STL) file. All teeth with the exception of two retained as landmarks were extracted, and seven implants were placed under local anesthesia and their positions recorded using photogrammetry. Maxillary and mandibular dental arch alginate impressions were made, poured in laboratory stone, and scanned. A provisional restoration was placed 7 hours after surgery using the STL files to determine the best-fit line. Radiographic and clinical follow-up after 1 year showed a favorable evolution of the implants. No screw loosening or other mechanical or biologic complications were observed. The case history using the described system suggests certain advantages over conventional techniques. More research is needed to assess the possible benefits associated with photogrammetry when making implant-supported restorations.

  9. Accuracy of six elastic impression materials used for complete-arch fixed partial dentures.

    PubMed

    Stauffer, J P; Meyer, J M; Nally, J N

    1976-04-01

    1. The accuracy of four types of impression materials used to make a complete-arch fixed partial denture was evaluated by visual comparison and indirect measurement methods. 2. None of the tested materials allows safe finishing of a complete-arch fixed partial denture on a cast poured from one single master impression. 3. All of the tested materials can be used for impressions for a complete-arch fixed partial denture provided it is not finished on one single cast. Errors can be avoided by making a new impression with the fitted castings in place. Assembly and soldering should be done on the second cast. 4. In making the master fixed partial denture for this study, inaccurate soldering was a problem that was overcome with the use of epoxy glue. Hence, soldering seems to be a major source of inaccuracy for every fixed partial denture.

  10. CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data.

    PubMed

    Goodacre, Charles J; Garbacea, Antoanela; Naylor, W Patrick; Daher, Tony; Marchack, Christopher B; Lowry, Jean

    2012-01-01

    The clinical impression procedures described in this article provide a method of recording the morphology of the intaglio and cameo surfaces of complete denture bases and also identify muscular and phonetic locations for the prosthetic teeth. When the CAD/CAM technology for fabricating complete dentures becomes commercially available, it will be possible to scan the denture base morphology and tooth positions recorded with this technique and import those data into a virtual tooth arrangement program where teeth can be articulated and then export the data to a milling device for the fabrication of the complete dentures. A prototype 3-D tooth arrangement program is described in this article that serves as an example of the type of program than can be used to arrange prosthetic teeth virtually as part of the overall CAD/CAM fabrication of complete dentures. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  11. A clinical study to compare between resting and stimulated whole salivary flow rate and pH before and after complete denture placement in different age groups

    PubMed Central

    Muddugangadhar, B. C.; Sangur, Rajashekar; Rudraprasad, I. V.; Nandeeshwar, D. B.; Kumar, B. H. Dhanya

    2015-01-01

    Purpose: This study compared the flow rate and pH of resting (unstimulated) and stimulated whole saliva before and after complete denture placement in different age groups. Materials and Methods: Fifty healthy, non-medicated edentulous individuals of different age groups requiring complete denture prostheses were selected from the outpatient department. The resting (unstimulated) and stimulated whole saliva and pH were measured at three stages i.e., i)Before complete denture placement;ii)Immediately after complete denture placement; andiii)After 2 to 3 months of complete denture placement. Saliva production was stimulated by chewing paraffin wax. pH was determined by using a digital pH meter. Results: Statistically significant differences were seen in resting(unstimulated) and stimulated whole salivary flow rate and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No statistically significant differences were found between the different age groups in resting (unstimulated) as well as stimulated whole salivary flow rate and pH. Conclusion: Stimulated whole salivary flow rates and pH were significantly higher than resting (unstimulated) whole salivary flow rates and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No age related variations in whole salivary flow rate and pH were observed in healthy, non-medicated individuals. Clinical Implications: The assessment of salivary flow rate, pH in different age groups is of prognostic value, which is an important aspect to be considered in the practice of removable prosthodontics. PMID:26929540

  12. A clinical study to compare between resting and stimulated whole salivary flow rate and pH before and after complete denture placement in different age groups.

    PubMed

    Muddugangadhar, B C; Sangur, Rajashekar; Rudraprasad, I V; Nandeeshwar, D B; Kumar, B H Dhanya

    2015-01-01

    This study compared the flow rate and pH of resting (unstimulated) and stimulated whole saliva before and after complete denture placement in different age groups. Fifty healthy, non-medicated edentulous individuals of different age groups requiring complete denture prostheses were selected from the outpatient department. The resting (unstimulated) and stimulated whole saliva and pH were measured at three stages i.e., i)Before complete denture placement;ii)Immediately after complete denture placement; andiii)After 2 to 3 months of complete denture placement. Saliva production was stimulated by chewing paraffin wax. pH was determined by using a digital pH meter. Statistically significant differences were seen in resting(unstimulated) and stimulated whole salivary flow rate and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No statistically significant differences were found between the different age groups in resting (unstimulated) as well as stimulated whole salivary flow rate and pH. Stimulated whole salivary flow rates and pH were significantly higher than resting (unstimulated) whole salivary flow rates and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No age related variations in whole salivary flow rate and pH were observed in healthy, non-medicated individuals. The assessment of salivary flow rate, pH in different age groups is of prognostic value, which is an important aspect to be considered in the practice of removable prosthodontics.

  13. Evaluation of the influence of blood glucose level on oral candidal colonization in complete denture wearers with Type-II Diabetes Mellitus: An in vivo Study.

    PubMed

    Ganapathy, Dhanraj Muthuveera; Joseph, Sajeesh; Ariga, Padma; Selvaraj, Anand

    2013-01-01

    Candidal colonization in complete denture wearers is a commonly encountered condition that worsens in the presence of untreated Diabetes Mellitus. The aim of this study was to evaluate the correlation between oral candidiasis in denture-bearing mucosa and elevated blood glucose levels in complete denture wearers and to evaluate the effect of oral hypoglycemic drug therapy in controlling oral candidal colonization in denture-bearing mucosa of complete denture wearers with Type II Diabetes Mellitus. This prospective observational study involved the participation of 15 complete denture wearers with Type II Diabetes Mellitus. The sample collection was made prior and after oral hypoglycaemic drug intervention, by swabbing the rugal surfaces of palatal mucosa, cultured and the density of the candidal colony formed was analyzed and interpreted as colony forming units (CFU) per mL. The candidal samples CFU and corresponding pre- and post-prandial blood glucose levels were estimated, analyzed and compared using Karl Pearson correlation analysis and paired t-test (α = 0.05). The Karl Pearson correlation analysis showed that there was a positive correlation between the blood glucose levels (PPS and FBS) and the candidal colonization (CFU) (P < 0.05). The mean values of all the variables were analyzed using the paired t-test. There was significant reduction in the mean values of blood glucose levels (P < 0.001) and the mean values of the CFU (P < 0.001) following oral hypoglycemic drug therapy. Positive correlation was observed between oral candidiasis in complete denture-bearing mucosa and elevated blood glucose levels and oral hypoglycemic drug therapy has a positive effect in controlling oral candidal colonization in complete denture wearers with Type II Diabetes Mellitus.

  14. The patient general satisfaction of mandibular single-implant overdentures and conventional complete dentures: Study protocol for a randomized crossover trial.

    PubMed

    Kanazawa, Manabu; Tanoue, Mariko; Miyayasu, Anna; Takeshita, Shin; Sato, Daisuke; Asami, Mari; Lam, Thuy Vo; Thu, Khaing Myat; Oda, Ken; Komagamine, Yuriko; Minakuchi, Shunsuke; Feine, Jocelyne

    2018-05-01

    Mandibular overdentures retained by a single implant placed in the midline of edentulous mandible have been reported to be more comfortable and function better than complete dentures. Although single-implant overdentures are still more costly than conventional complete dentures, there are a few studies which investigated whether mandibular single-implant overdentures are superior to complete dentures when patient general satisfaction is compared. The aim of this study is to assess patient general satisfaction with mandibular single-implant overdentures and complete dentures. This study is a randomized crossover trial to compare mandibular single-implant overdentures and complete dentures in edentulous individuals. Participant recruitment is ongoing at the time of this submission. Twenty-two participants will be recruited. New mandibular complete dentures will be fabricated. A single implant will be placed in the midline of the edentulous mandible. The mucosal surface of the complete denture around the implant will be relieved for 3 months. The participants will then be randomly allocated into 2 groups according to the order of the interventions; group 1 will receive single-implant overdentures first and will wear them for 2 months, followed by complete dentures for 2 months. Group 2 will receive the same treatments in a reverse order. After experiencing the 2 interventions, the participants will choose one of the mandibular prostheses, and yearly follow-up visits are planned for 5 years. The primary outcome of this trial is patient ratings of general satisfaction on 100 mm visual analog scales. Assessments of the prostheses and oral health-related quality of life will also be recorded as patient-reported outcomes. The secondary outcomes are cost and time for treatment. Masticatory efficiency and cognitive capacity will also be recorded. Furthermore, qualitative research will be performed to investigate the factors associated with success of these mandibular denture types. Clinical outcomes, such as implant survival rate, marginal bone loss, and prosthodontic complications, will also be recorded. The results of this randomized crossover trial will clarify whether mandibular single implants and overdentures for edentulous individuals provide better patient general satisfaction when compared to conventional complete dentures. This clinical trial was registered at the University Hospital Medical Information Network (UMIN) Center (UMIN000017883).

  15. IMPROVDENT: improving dentures for patient benefit. A crossover randomised clinical trial comparing impression materials for complete dentures.

    PubMed

    Gray, Janine C; Navarro-Coy, Nuria; Pavitt, Sue H; Hulme, Claire; Godfrey, Mary; Craddock, Helen L; Brunton, Paul A; Brown, Sarah; Dillon, Sean; Dukanovic, Gillian; Fernandez, Catherine; Wright, Jonathan; Collier, Howard; Swithenbank, Shirley; Lee, Carol; Hyde, T Paul

    2012-08-31

    According to the UK Adult Dental Health Survey (2009) 15% of adults aged 65-74, 30% aged 75-84 and 47% aged >85 years are edentulous and require complete dentures. Patients' quality of life and nutrition status are affected by poor dentures. The quality of the dental impression is the most important issue for improving the fit and comfort of new dentures. There is paucity of RCT evidence for which impression material is best for complete dentures construction. This study aims to compare two impression materials for effectiveness and cost effectiveness. IMPROVDENT is a double-blind crossover trial comparing the use of alginate and silicone, two commonly used denture impression materials, in terms of patient preference and cost-effectiveness. Eighty five edentulous patients will be recruited and provided with two sets of dentures, similar in all aspects except for the impression material used (alginate or silicone). Patients will try both sets of dentures for a two-week period, unadjusted, to become accustomed to the feel of the new dentures (habituation period). Patients will then wear each set of dentures for a period of 8 weeks (in random order) during which time the dentures will be adjusted for optimum comfort. Finally, patients will be given both sets of dentures for a further two weeks to wear whichever denture they prefer (confirmation period).Patients will be asked about quality of life and to rate dentures on function and comfort at the end of each trial period and asked which set they prefer at the end of the habituation period (unadjusted denture preference) and confirmation period (adjusted denture preference). A health economic evaluation will estimate incremental cost-effectiveness ratios of producing dentures from the two materials. A qualitative study will investigate the impact of dentures on behaviour and quality of life. IMPROVDENT is funded by NIHR RfPB (PB-PG-0408-16300). This trial aims to provide evidence on the costs and quality of dentures cast from two different commonly used impression materials; the intention is to significantly impact on the quality of denture production within NHS dentistry. ISRCTN Register: ISRCTN01528038 UKCRN Portfolio ID: 8305.

  16. Attitudes and usage of denture adhesives by complete denture wearers: a survey in Greece and the Netherlands.

    PubMed

    Polyzois, Gregory L; de Baat, Cees

    2012-06-01

    To explore whether there are differences in usage of and attitudes towards denture adhesives among patients in two countries. There are no multi-country surveys concerning usage of and attitudes towards denture adhesives from complete denture wearers. The survey took place in Greece and the Netherlands with a sample of 284 and 165 consecutive complete denture wearers, respectively, by using a 9-item prepared questionnaire. Statistical analysis relied on chi-square test at α = 0.05. In this survey, 26 and 20% of Greek and Dutch patients, respectively, had tried denture adhesive, but only 27% of them in Greece as well as in the Netherlands currently used it; 49% of the Greek and 45% of the Dutch participants rated the overall performance of adhesives as good. Between the two populations, no differences were identified in a majority of the research variables, except where 27% of Greeks answered that they did not know the existence of denture adhesives compared to none of the Dutch patients and when 90% of the Dutch contrary to 70% of Greeks reported that they did not need denture adhesives as they could manage their dentures well. The usage of and attitudes towards denture adhesives between the Greek and Dutch sample were similar with only two exceptions concerning the knowledge of existence and the need of using denture adhesives. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  17. Maxillary reconstruction to enable implant insertion: a retrospective study of 181 patients

    PubMed Central

    Ferri, Joël; Dujoncquoy, Jean-Pascal; Carneiro, José Mario; Raoul, Gwénael

    2008-01-01

    Background The purpose of the present study was to evaluate different types of maxillary pre-prosthetic surgery using autogenous bone graft and suggest a guideline for maxillary reconstruction to place implant. Methods 181 patients (125 females and 56 males), age range from 16 to 76 years old, were operated at the Maxillo-Facial Service of the Lille's 2 Universitary Hospital Center (Chairman Pr Joël Ferri). Different techniques were used, but always with autogenous bone grafting. 21 patients underwent a Lefort 1 procedure, 139 underwent sinus graft with or without vestibular onlay graft and 21 underwent onlay graft. This surgical procedure was made to allow the insertion of 685 implants. Results The patients were evaluated by clinical and radiological assessment. In the cases of Lefort 1, the rate of successful osteointegration was higher when the implants were placed in the second part of a two stages procedure: 92%, against 81% for one stage. In cases of sinus lift procedure, the rate of implant success was 98%. The infection rate was 3.5%. There was no significant resorption and the type of prosthesis used was a denture retained by a bar or fixed bridge. In cases of onlay graft, the implant insertion success was 97% and there was no infection. The amount of resorption was more significant in the pre-maxilla than in the other areas and the type of prosthesis used was fixed dentures. Conclusion These observations demonstrate that: the aetiology of the bone defect indicate the type and number of the surgical procedures to re-established good jaws relationship and give the bone conditions to implant insertion successful. Clinical Relevance A guideline for surgical decision in the maxillary reconstruction for oral rehabilitation by implants may help to prevent failures of osseous resorption disorders and to foresee the investment of the bone in quality and necessary quantity. PMID:19087352

  18. The Role of New Removable Complete Dentures in Stimulated Salivary Flow and Taste Perception.

    PubMed

    Tango, Rubens Nisie; Arata, Anelyse; Borges, Alexandre Luiz Souto; Costa, Anna K F; Pereira, Luciano Jose; Kaminagakura, Estela

    2018-04-01

    To evaluate the effect of replacement of inadequate complete dentures on salivary flow and taste perception in geriatric patients. Thirty-three patients, 13 males and 20 females, with a mean age of 64.4 years were submitted to stimulated and unstimulated salivary flow rate and salivary pH measurements, and sense of taste evaluation. Tests were performed 3 months before complete denture substitution and 3 weeks after denture insertion. The mean for unstimulated saliva (USS) was 2.1 ml before and 2.7 ml after replacement (p = 0.003). The mean volume of stimulated saliva was 6.3 ml before and 8.2 ml after replacement (p = 0.004). The pH mean of USS was 7.8 ± 0.44 before and 8.02 ± 0.41 after replacement (p = 0.005). No statistically significant difference was determined in the sense of taste before and 3 weeks after complete denture replacement. The replacement of inadequate complete dentures increases saliva flow; however, it does not improve taste perception. © 2016 by the American College of Prosthodontists.

  19. Kinematics modeling and experimentation of the multi-manipulator tooth-arrangement robot for full denture manufacturing.

    PubMed

    Zhang, Yong-de; Jiang, Jin-gang; Liang, Ting; Hu, Wei-ping

    2011-12-01

    Artificial teeth are very complicated in shape, and not easy to be grasped and manipulated accurately by a single robot. The method of tooth-arrangement by multi-manipulator for complete denture manufacturing proposed in this paper. A novel complete denture manufacturing mechanism is designed based on multi-manipulator and dental arch generator. Kinematics model of the multi-manipulator tooth-arrangement robot is built by analytical method based on tooth-arrangement principle for full denture. Preliminary experiments on tooth-arrangement are performed using the multi-manipulator tooth-arrangement robot prototype system. The multi-manipulator tooth-arrangement robot prototype system can automatically design and manufacture a set of complete denture that is suitable for a patient according to the jaw arch parameters. The experimental results verified the validity of kinematics model of the multi-manipulator tooth-arrangement robot and the feasibility of the manufacture strategy of complete denture fulfilled by multi-manipulator tooth-arrangement robot.

  20. A Three Month Comparative Evaluation of the Effect of Different Surface Treatment Agents on the Surface Integrity and Softness of Acrylic based Soft Liner: An In vivo Study

    PubMed Central

    Mahajan, Neerja; Naveen, Y. G.; Sethuraman, Rajesh

    2017-01-01

    Introduction Acrylic based soft liners are cost effective, yet are inferior in durability as compared to silicone based liners. Hence, this study was conducted to evaluate if the softness and surface integrity of acrylic based soft liner can be maintained by using different surface treatment agents. Aim To comparatively evaluate the effects of Varnish, Monopoly and Kregard surface treatment agents on the surface integrity and softness of acrylic based soft liner at baseline, at one month and after three months. Materials and Methods A total of 37 participants who required conventional maxillary dentures were selected according to the determined inclusion and exclusion criteria of the study. In the maxillary denture on the denture bearing surface, eight palatal recesses (5 mm x 3 mm) were made and filled with acrylic based soft liner (Permasoft). The soft liners in these recesses were given surface treatment and divided as control (uncoated), Varnish, Monopoly and Kregard groups. The hardness and surface integrity were evaluated with Shore A Durometer and Scanning Electron Microscope (SEM) respectively at baseline, one month and three months interval. Surface integrity between groups was compared using Kruskal-Wallis test. Intergroup comparison for hardness was done using ANOVA and Tukey’s HSD post-hoc tests. Results Amongst all the groups tested, surface integrity was maintained in the Kregard group, as compared to control, Varnish and Monopoly groups for all three time intervals (p< 0.001). Kregard treated samples also demonstrated significantly higher softness at all the time intervals (p<0.001). Conclusion Surface treatment with Kregard demonstrated better surface integrity and softness at all the time intervals. PMID:29207842

  1. Improvised Neutral Zone Technique in a Completely Edentulous Patient with an Atrophic Mandibular Ridge and Neuromuscular Incoordination: A Clinical Tip

    PubMed Central

    Thirumalai Thangarajan, Saravanan; Mani, Umamaheswari; Kumar V, Anand

    2017-01-01

    Resorption of mandibular ridges is a multifactorial and biomechanical disease that is chronic, progressive, irreversible, and cumulative leading to loss of sulcular depth, vertical dimension loss, and decreased lower facial height. Some common neurological, hormonal, and metabolic disorders affect the adaptability of dentures, and this can be diagnosed by a trained prosthodontist with proper history-taking and clinical examination.The denture becomes passive due to complex neuromuscular control and causes difficulties in impression-making, mastication, and swallowing, which in turn leads to loss of retention and stability in complete dentures. Hence, residual ridge resorption becomes a challenging scenario for a clinician during fabrication of complete dentures. The neutral zone concept plays a significant role in overcoming these challenges. The neutral zone is the area where the outward forces from the tongue are neutralized or nullified by the forces of the lips and cheeks acting inward during functional movements.The neutral zone technique is an alternative approach for the construction of lower complete dentures. It is most effective for dentures where there is a highly atrophic ridge and history of denture instability. The technique aims to construct a denture that is shaped by muscle function and is in harmony with the surrounding oral structures. The technique is by no means new, but it is a valuable one. It is rarely used because of the extra clinical step involved and its complexity. Complete and partial denture failures are often related to non-compliance with neutral zone factors. Thus, the evaluation of the neutral zone is an important factor. Increased retention and stability with reduced chairside time are the salient features of this new approach to any clinically challenging situation in complete dentures.This clinical report describes a modification of the conventional neutral zone technique using improvised procedures to minimize chairside visits for a patient with an atrophic mandibular ridge and neuromuscular incoordination. PMID:28553567

  2. Improvised Neutral Zone Technique in a Completely Edentulous Patient with an Atrophic Mandibular Ridge and Neuromuscular Incoordination: A Clinical Tip.

    PubMed

    Saravanakumar, Prathibha; Thirumalai Thangarajan, Saravanan; Mani, Umamaheswari; Kumar V, Anand

    2017-04-24

    Resorption of mandibular ridges is a multifactorial and biomechanical disease that is chronic, progressive, irreversible, and cumulative leading to loss of sulcular depth, vertical dimension loss, and decreased lower facial height. Some common neurological, hormonal, and metabolic disorders affect the adaptability of dentures, and this can be diagnosed by a trained prosthodontist with proper history-taking and clinical examination.The denture becomes passive due to complex neuromuscular control and causes difficulties in impression-making, mastication, and swallowing, which in turn leads to loss of retention and stability in complete dentures. Hence, residual ridge resorption becomes a challenging scenario for a clinician during fabrication of complete dentures. The neutral zone concept plays a significant role in overcoming these challenges. The neutral zone is the area where the outward forces from the tongue are neutralized or nullified by the forces of the lips and cheeks acting inward during functional movements.The neutral zone technique is an alternative approach for the construction of lower complete dentures. It is most effective for dentures where there is a highly atrophic ridge and history of denture instability. The technique aims to construct a denture that is shaped by muscle function and is in harmony with the surrounding oral structures. The technique is by no means new, but it is a valuable one. It is rarely used because of the extra clinical step involved and its complexity. Complete and partial denture failures are often related to non-compliance with neutral zone factors. Thus, the evaluation of the neutral zone is an important factor. Increased retention and stability with reduced chairside time are the salient features of this new approach to any clinically challenging situation in complete dentures.This clinical report describes a modification of the conventional neutral zone technique using improvised procedures to minimize chairside visits for a patient with an atrophic mandibular ridge and neuromuscular incoordination.

  3. Effect of complete dentures on dynamic measurement of changing head position: A pilot study.

    PubMed

    Usumez, Aslihan; Usumez, Serdar; Orhan, Metin

    2003-10-01

    Complete dentures contribute significantly to the facial esthetics of edentulous patients. However, information as to the effect of complete dentures on the natural position of the head is limited. The purpose of this pilot study was to evaluate the immediate and 30-day effect of wearing complete dentures on the dynamic natural head position measured during walking. The sample consisted of a volunteer group of 16 patients, 8 women and 8 men, who received new complete dentures. The ages of the subjects ranged from 45 to 64 years (mean=52 years). Dynamic measurement of head posture was carried out by a specially constructed inclinometer device. Each subject in turn was fitted with the inclinometer system and instructed to walk in a relaxed manner for 5 minutes. The data, measured as degrees, were stored in a pocket data logger. This procedure was repeated before insertion of dentures (T1), immediately after insertion of dentures (T2), and 30 days after insertion of dentures (T3). Stored dynamic head posture data were transferred to computer for analysis. The means of the measurements were statistically compared with Friedman and following Wilcoxon tests (alpha =.05). Twelve of 16 (75%) subjects showed an average of 4.6 degrees of cranial extension immediately after insertion of dentures. Six (37.5%) subjects showed an average of 6.4 degrees of cranial flexion, and 8 (50%) subjects showed an average of 5.2 degrees of cranial extension at T3 relative to the T1 measurement. Dynamic head posture measurements of the other 2 subjects remained unchanged. There were significant differences between different measurements of dynamic head posture positions (P<.025). However, only the T1 and T2 measurements were significantly different (P<.015). The findings indicate that the statistically significant average extension 4.6 degrees in subjects immediately after insertion of complete dentures was not stable after a 30-day evaluation period and did not produce any statistically significant change. The overall effect of wearing dentures was an irregular flexion or extension pattern on dynamic head posture.

  4. Improvdent: Improving dentures for patient benefit. A crossover randomised clinical trial comparing impression materials for complete dentures

    PubMed Central

    2012-01-01

    Background According to the UK Adult Dental Health Survey (2009) 15% of adults aged 65–74, 30% aged 75–84 and 47% aged >85 years are edentulous and require complete dentures. Patients’ quality of life and nutrition status are affected by poor dentures. The quality of the dental impression is the most important issue for improving the fit and comfort of new dentures. There is paucity of RCT evidence for which impression material is best for complete dentures construction. This study aims to compare two impression materials for effectiveness and cost effectiveness. Methods/Design IMPROVDENT is a double-blind crossover trial comparing the use of alginate and silicone, two commonly used denture impression materials, in terms of patient preference and cost-effectiveness. Eighty five edentulous patients will be recruited and provided with two sets of dentures, similar in all aspects except for the impression material used (alginate or silicone). Patients will try both sets of dentures for a two-week period, unadjusted, to become accustomed to the feel of the new dentures (habituation period). Patients will then wear each set of dentures for a period of 8 weeks (in random order) during which time the dentures will be adjusted for optimum comfort. Finally, patients will be given both sets of dentures for a further two weeks to wear whichever denture they prefer (confirmation period). Patients will be asked about quality of life and to rate dentures on function and comfort at the end of each trial period and asked which set they prefer at the end of the habituation period (unadjusted denture preference) and confirmation period (adjusted denture preference). A health economic evaluation will estimate incremental cost-effectiveness ratios of producing dentures from the two materials. A qualitative study will investigate the impact of dentures on behaviour and quality of life. Funding: IMPROVDENT is funded by NIHR RfPB (PB-PG-0408-16300). Discussion This trial aims to provide evidence on the costs and quality of dentures cast from two different commonly used impression materials; the intention is to significantly impact on the quality of denture production within NHS dentistry. Trial Registration ISRCTN Register: ISRCTN01528038 UKCRN Portfolio ID: 8305 PMID:22937901

  5. A clinical study to evaluate the correlation between maxillary central incisor tooth form and face form in an Indian population.

    PubMed

    Koralakunte, Pavankumar R; Budihal, Dhanyakumar H

    2012-09-01

    A study was performed to examine the correlation between maxillary central incisor tooth form and face form in males and females in an Indian population. The selection of prosthetic teeth for edentulous patients is a primary issue in denture esthetics, especially in the case of maxillary central incisors, which are the most prominent teeth in the arch. Two hundred dental students of Indian origin comprising 79 males and 121 females aged 18-28 years studying at Bapuji Dental College and Hospital were randomly selected as the study subjects. A standardized photographic procedure was used to obtain images of the face and the maxillary central incisors. The outline forms of the face and the maxillary right central incisor tooth were determined using a standardized method. The outline forms obtained were used to classify both face form and tooth form on the basis of visual and William's methods. The means were considered after evaluation by five prosthodontists, and the results were tabulated. Statistical analysis was performed using the chi-squared test for association and Z-test for equality of proportions. A correlation greater than 50% was observed between tooth form and face form by the visual method, compared with one of 31.5% by William's method. There was no highly defined correlation between maxillary central incisor tooth form and face form among the male and female Indian subjects studied.

  6. The maxillary second molar - anatomical variations (case report).

    PubMed

    Beshkenadze, E; Chipashvili, N

    2015-01-01

    To be acquainted with dental anatomical specificity is of great importance for dental endodontic treatment algorithm. The subject of present publication is 2 clinical cases of upper second molars, detailed characterization of, which is considered very important for enrichment of anatomical knowledge about dental anatomical variations. In one case, the reason for admission to the clinic of a 38-year-old woman was complains as of esthetic character as well as functional misbalance (disturbance of chewing function due to the damage of orthopedic construction). The patient indicated to the existence of coronary defects of large size aesthetic discomforts, damage and discolouration of old orthopedic construction (denture) in maxillary right molar area. According to the data obtained after clinical and visiographical examinations, chronic periodontitis of 17 teeth was identified as a result of incomplete endodontic treatment. According to the data obtained after clinical and visiographical examinations, the diagnosis of chronic periodontitis of 17 teeth was identified, tooth 17 with 2 roots and 2 canals. In the second clinical case, the reason for admission to the clinic of a 39-year-old woman was severe pain in the upper right molar area. The patient indicated to the caries on the tooth 17. After completion of proper survey clinical and visiographical examinations, acute pulpitis (K04.00) - with three roots and 4 canals was diagnosed. In both cases after the proper examinations and agreement with the patients a treatment plan envisaging: 17 teeth endodontic treatment, filling of caries defects and their preparation on one hand for orthopedic construction (denture) and on the other hand for restoration of anatomical integrity by light-cured composite, was scheduled. The present study is designed to prevent complications of endodontic treatment of the second molar, to optimize diagnosis and treatment algorithm, once again proving reliable information indicating to the individuality of treatment tactics.

  7. Functional Impressions in Complete Denture and Overdenture Treatment

    PubMed Central

    Kršek, Hrvoje

    2015-01-01

    Tooth loss can cause loss of occlusal, masticatory, esthetic, physiognomic, phonetic and psychosocial function of patients. The most frequently used treatment method of completely edentulous patients and patients with a small number of remaining teeth are complete dentures or overdentures. One of the most important clinical and laboratory procedures in their fabrication is functional impression taking. The aim of this paper was to present procedures of taking functional impressions in fabrication of complete dentures and overdentures, using standardized techniques and materials. An accurate functional impression together with other correctly performed clinical and laboratory procedures ensure good retention and stability of dentures, which is a precondition for restoring patients’ lost functions. PMID:27688385

  8. The Effect of Different Chemical Surface Treatments of Denture Teeth on Shear Bond Strength: A Comparative Study

    PubMed Central

    Palekar, Umesh; Awinashe, Vaibav; Mishra, Sunil Kumar; Kawadkar, Abhishek; Rahangdale, Tripti

    2014-01-01

    Background: The development of better cross linked acrylic resin teeth has solved the problems related to wearing and discoloration of acrylic teeth. The same cross linking at ridge lap region acts as a double edge sword as it weakens the bond between denture base and tooth. Aim of Study: The purpose of study was to evaluate the effect of surface treatment on the bond strength of resin teeth to denture base resin using monomethyl methacrylate monomer and dichloromethane with no surface treatment acting as control. Settings and Design:Denture base cylinder samples in wax (n=180) were made with maxillary central incisor attached at 450 (JIST 6506). These samples were randomly and equally divided into three groups of 60 each. These specimens were then flasked, dewaxed as per the standard protocol. Materials and Methods: Before acrylization, ridge lap area was treated as follows: Group A- no surface treatment act as control, Group B treated with monomethyl methacrylate monomer, Group C treated with dichloromethane. Digitally controlled acryliser was used for acrylization as per manufacturer’s instructions and shear bond strength was tested on Universal Testing Machine (Servo Hydraulic, 50kN High Strain, BISS Research). Statistical Analysis used: Result was statistically analyzed with One-way analysis of variance (ANOVA) and Post-hoc ANOVA Tukey’s HSD test at 5% level of significance. Results: The application of dichloromethane showed increased bond strength between cross linked acrylic resin teeth and heat cure denture base resin followed by monomethyl methacrylate monomer and control group. Conclusion: The application of dichloromethane on the ridge lap surface of the resin teeth before packing of the dough into the mold significantly increased the bond strength between cross linked acrylic resin teeth and heat cure denture base resin. PMID:25121057

  9. Complete denture tooth arrangement technology driven by a reconfigurable rule.

    PubMed

    Dai, Ning; Yu, Xiaoling; Fan, Qilei; Yuan, Fulai; Liu, Lele; Sun, Yuchun

    2018-01-01

    The conventional technique for the fabrication of complete dentures is complex, with a long fabrication process and difficult-to-control restoration quality. In recent years, digital complete denture design has become a research focus. Digital complete denture tooth arrangement is a challenging issue that is difficult to efficiently implement under the constraints of complex tooth arrangement rules and the patient's individualized functional aesthetics. The present study proposes a complete denture automatic tooth arrangement method driven by a reconfigurable rule; it uses four typical operators, including a position operator, a scaling operator, a posture operator, and a contact operator, to establish the constraint mapping association between the teeth and the constraint set of the individual patient. By using the process reorganization of different constraint operators, this method can flexibly implement different clinical tooth arrangement rules. When combined with a virtual occlusion algorithm based on progressive iterative Laplacian deformation, the proposed method can achieve automatic and individual tooth arrangement. Finally, the experimental results verify that the proposed method is flexible and efficient.

  10. Dental erosion caused by gastroesophageal reflux disease: a case report

    PubMed Central

    Cengiz, M İnanç; Saraç, Y Şinasi

    2009-01-01

    Introduction Chronic regurgitation of gastric acids in patients with gastroesophageal reflux disease may cause dental erosion, which can lead in combination with attrition or bruxism to extensive loss of coronal tooth tissue. Case presentation This clinical report describes treatment of severe tooth wear of a gastroesophageal reflux disease patient who is 54-year-old Turkish male patient. After his medical treatment, severe tooth wear, bruxism and decreased vertical dimensions were determined. The vertical dimension was re-established and maxillary and mandibular anterior and posterior teeth were prepared for metal-ceramic restorations. Metal-ceramic fixed partial dentures were fabricated as full mouth restorations for both maxillary and mandibular arches because of splinting all teeth. And then maxillary stabilization splint was fabricated for his bruxism history. Conclusion Significant loss of coronal tooth structure must taken into consideration. Gastroesophageal reflux disease by itself or in combination with attrition, abrasion or bruxism may be responsible for the loss. An extensive diagnostic evaluation is essential for the medical and dental effects of the problem. PMID:19830044

  11. Dental erosion caused by gastroesophageal reflux disease: a case report.

    PubMed

    Cengiz, Seda; Cengiz, M Inanç; Saraç, Y Sinasi

    2009-07-22

    Chronic regurgitation of gastric acids in patients with gastroesophageal reflux disease may cause dental erosion, which can lead in combination with attrition or bruxism to extensive loss of coronal tooth tissue. This clinical report describes treatment of severe tooth wear of a gastroesophageal reflux disease patient who is 54-year-old Turkish male patient. After his medical treatment, severe tooth wear, bruxism and decreased vertical dimensions were determined. The vertical dimension was re-established and maxillary and mandibular anterior and posterior teeth were prepared for metal-ceramic restorations. Metal-ceramic fixed partial dentures were fabricated as full mouth restorations for both maxillary and mandibular arches because of splinting all teeth. And then maxillary stabilization splint was fabricated for his bruxism history. Significant loss of coronal tooth structure must taken into consideration. Gastroesophageal reflux disease by itself or in combination with attrition, abrasion or bruxism may be responsible for the loss. An extensive diagnostic evaluation is essential for the medical and dental effects of the problem.

  12. Study protocol for a multi-center, randomized controlled trial to develop Japanese denture adhesive guidelines for patients with complete dentures: the Denture Adhesive Guideline trial: study protocol for a randomized controlled trial.

    PubMed

    Kimoto, Suguru; Kawai, Yasuhiko; Gunji, Atsuko; Kondo, Hisatomo; Nomura, Taro; Murakami, Tomohiko; Tsuboi, Akito; Hong, Guang; Minakuchi, Shunsuke; Sato, Yusuke; Ohwada, Gaku; Suzuki, Tetsuya; Kimoto, Katsuhiko; Hoshi, Noriyuki; Saita, Makiko; Yoneyama, Yoshikazu; Sato, Yohei; Morokuma, Masakazu; Okazaki, Joji; Maeda, Takeshi; Nakai, Kenichiro; Ichikawa, Tetsuo; Nagao, Kan; Fujimoto, Keiko; Murata, Hiroshi; Kurogi, Tadafumi; Yoshida, Kazuhiro; Nishimura, Masahiro; Nishi, Yasuhiro; Murakami, Mamoru; Hosoi, Toshio; Hamada, Taizo

    2016-10-18

    Denture adhesives, characterized as medical products in 1935 by the American Dental Association, have been considered useful adjuncts for improving denture retention and stability. However, many dentists in Japan are hesitant to acknowledge denture adhesives in daily practice because of the stereotype that dentures should be inherently stable, without the aid of adhesives. The aim of this study is to verify the efficacy of denture adhesives to establish guidelines for Japanese users. The null hypothesis is that the application of denture adhesives, including the cream and powder types, or a control (isotonic sodium chloride solution) would not produce different outcomes nor would they differentially improve the set outcomes between baseline and day 4 post-application. This ten-center, randomized controlled trial with parallel groups is ongoing. Three hundred edentulous patients with complete dentures will be allocated to three groups (cream-type adhesive, powder-type adhesive, and control groups). The participants will wear their dentures with the denture adhesive for 4 days, including during eight meals (three breakfasts, two lunches, and three dinners). The baseline measurements and final measurements for the denture adhesives will be performed on the first day and after breakfast on the fourth day. The primary outcome is a general satisfaction rating for the denture. The secondary outcomes are denture satisfaction ratings for various denture functions, occlusal bite force, resistance to dislodgement, masticatory performance, perceived chewing ability, and oral health-related quality of life. Between-subjects comparisons among the three groups and within-subjects comparisons of the pre- and post-intervention measurements will be performed. Furthermore, a multiple regression analysis will be performed. The main analyses will be based on the intention-to-treat principle. A sample size of 100 subjects per group, including an assumed dropout rate of 10 %, will be required to achieve 80 % power with a 5 % alpha level. This randomized clinical trial will provide information about denture adhesives to complete denture wearers, prosthodontic educators, and dentists in Japan. We believe this new evidence on denture adhesive use from Japan will aid dentists in their daily practice even in other countries. ClinicalTrials.gov NCT01712802 . Registered on 17 October 2012.

  13. Sectional mandibular complete denture for a total maxillectomy patient with trismus: a clinical report.

    PubMed

    Celakil, Tamer; Demir, Azize; Keskin, Haluk

    2017-01-01

    This report presents the case of a 60-year-old male patient with trismus induced by radiotherapy and fabrication of a sectional mandibular complete denture to allow the insertion of the denture into the mouth. A mandibular sectional denture was designed in two pieces with a locking mechanism by using mini anchor and ball abutment housing with cap. Patients who have undergone maxillectomy often have constricted mouth openings, as a result of surgical intervention and radiotherapy, and complain of an inability to insert or remove dentures. A new approach is vital for sectional dentures because existing sectional denture fabrication techniques cannot meet the ongoing needs of trismus patients. The mini anchor system with ball abutment housing has better mechanical retention in acrylic resin and can provide favorable stabilization during masticatory function; thus, additional framework is not required for assisting in stabilization and retention.

  14. Simplified Prosthetic Rehabilitation of a Patient after Oral Cancer Removal.

    PubMed

    Kranjčić, Josip; Džakula, Nikola; Vojvodić, Denis

    2016-09-01

    The treatment of patients with oral cancer is complex: a multidisciplinary approach needs to be taken and maxillofacial and oral surgeons, an oncologist, a prosthodontist should be included, and a psychologist is often needed. This case report describes the prosthetic rehabilitation of a patient after surgical removal of oral cancer with obturator prosthesis. Resection cavity was located in central part of the hard palate and the condition belonged to Aramany class 3 maxillary defects. The two-step impression technique of denture bearing area was used and the resection of cavity was performed. A primary impression-the impression of denture bearing area was made using irreversible hydrocolloid material, while the second impression - the impression of resection cavity was made using condensation silicone material and obturator prosthesis framework. The obturator prosthesis replaced lost teeth, improved oral function and esthetics at minimal costs.

  15. Biomechanical factors related to occlusal load transfer in removable complete dentures.

    PubMed

    Żmudzki, Jarosław; Chladek, Grzegorz; Kasperski, Jacek

    2015-08-01

    Owing to economic conditions, removable dentures remain popular despite the discomfort and reduced chewing efficiency experienced by most denture wearers. However, there is little evidence to confirm that the level of mucosal load exceeds the pressure pain threshold. This discrepancy stimulated us to review the current state of knowledge on the biomechanics of mastication with complete removable dentures. The loading beneath dentures was analyzed in the context of denture foundation characteristics, salivary lubrication, occlusal forces, and the biomechanics of mastication. The analysis revealed that the interpretation of data collected in vivo is hindered due to the simultaneous overlapping effects of many variables. In turn, problems with determining the pressure beneath a denture and analyzing frictional processes constitute principal limitations of in vitro model studies. Predefined conditions of finite element method simulations should include the effects of oblique mastication forces, simultaneous detachment and sliding of the denture on its foundation, and the stabilizing role of balancing contacts. This review establishes that previous investigations may have failed because of their unsubstantiated assumption that, in a well-working balanced occlusion, force is only exerted perpendicular to the occlusal plane, allowing the denture to sit firmly on its foundation. Recent improvements in the simulation of realistic biomechanical denture behavior raise the possibility of assessing the effects of denture design on the pressures and slides beneath the denture.

  16. One-Piece Implant-Retained Mandibular Overdentures By Pre-Fabricated Titanium Telescopic Attachments and Frictional Varnish: A Two-Year Prospective Study.

    PubMed

    Nik, Shahram Namjoy; Nejatian, Touraj

    2016-12-01

    Clinical efficiency of one-piece screw-type implants with telescopic were attachments evaluated in this study. Twenty-four patients received a mandibular implant-supported overdenture and maxillary complete denture. Ninety-six one-piece implants were inserted in the inter-foraminal area. Implants were immediately loaded with an implant-retained overdenture and telescopic attachments which had frictional retention elements. There was 0.25±0.24 mm, 0.32±0.25 mm, 0.43±0.30 mm, 0.61±0.30 mm and of bone resorption after 3, 6, 12 and 24 months, respectively. The need to activate the frictional retention was the most common complication. Treatment outcomes for prefabricated telescopic retained overdentures on one-piece implants are similar to that obtained in cases of delayed loading. Copyright© 2016 Dennis Barber Ltd.

  17. Prosthodontic Management of Hypohidrotic Ectodermal Dysplasia with Anodontia: A Case Report in Pediatric Patient and Review of Literature

    PubMed Central

    Ladda, R; Gangadhar, SA; Kasat, VO; Bhandari, AJ

    2013-01-01

    Ectodermal dysplasias are rare hereditary disorders characterized by abnormal development of certain tissues and structures of ectodermal origin. The condition is important for dentists as it affects teeth resulting in hypodontia or anodontia and dentist plays an important role in rehabilitation of the patient. Affected young children with anodontia not only have difficulties in eating and speaking but can also feel that they look different from their contemporaries. Well-fitting and functioning prosthesis could be a great help during their schooling years as it will improve appearance and thus boost their self confidence. We report a case of hypohidrotic ectodermal dysplasia in an 8-year-old boy who exhibited anodontia and was successfully rehabilitated with conventional complete dentures in both maxillary and mandibular arches. The aim of the treatment was to improve psychological development apart from promoting better functioning of the stomatognathic system. PMID:23919206

  18. Heat-cured acrylic resin versus light-activated resin: a patient, professional and technician-based evaluation of mandibular implant-supported overdentures.

    PubMed

    Asal, S A; Al-AlShiekh, H M

    2017-12-01

    Although light-activated resins (Eclipse) have been reported to possess superior physical and mechanical properties compared with the heat-cured acrylic resins (Lucitone-199), a few studies have compared overdentures with a locator attachment constructed from heat-cured acrylic resins with those constructed from light-activated resins. This clinical study was designed to compare the performance of a mandibular implant-supported overdenture constructed from a heat-cured acrylic resin (Lucitone-199) with that of an overdenture constructed from a light-activated resin (Eclipse). Ten participants received two identical mandibular implant-retained overdentures (Lucitone-199 and Eclipse) opposing one maxillary denture in a random order. Each mandibular overdenture was delivered and worn for 6 months, and two weeks of rest was advised between wears to minimize any carryover effects. Three questionnaires were devised. The first questionnaire (patient evaluation) focused on evaluating different aspects of the denture and overall satisfaction. The second questionnaire (professional dentist evaluation) was based on a clinical evaluation of soft tissues, complications, and the applied technique. The third questionnaire (technician evaluation) involved ranking the different manufacturing steps of the denture and overall preferences. The obtained data was statistically analyzed using an independent sample t-test and the Wilcoxon rank-sum test. The clinician and technician preferred the Eclipse dentures because of their technical aspects, whereas the patients preferred the Lucitone-199 dentures for their aesthetic properties. Implant-supported overdentures constructed from a heat-cured acrylic resin showed superior aesthetics and had a better odor compared with those constructed from a light-cured resin.

  19. All on Four® fixed implant support rehabilitation: a masticatory function study.

    PubMed

    De Rossi, Moara; Santos, Carla Moreto; Migliorança, Reginaldo; Regalo, Simone Cecílio Hallak

    2014-08-01

    Fixed implant-supported prostheses according to All-on-Four® (Nobel Biocare, Goteborg, Sweden) principles have become an accepted treatment modality in totally edentulous patients, whereas the functional effect of this therapy is limited. The purpose of this study was to evaluate the muscular function of patients totally rehabilitated with All-on-Four. This study evaluated 63 patients. Twenty-one patients were successfully rehabilitated with maxillary and mandibular All-on-Four (no dropout implants, satisfactory aesthetic and function demands prosthesis), 21 patients were dentate, and 21 were rehabilitated with double complete dentures. Electromyography was carried out during clenching, nonhabitual and habitual chewing, and rest. All values were standardized as percentage of a maximum voluntary contraction. Data were analyzed by ANOVA to compare groups and paired t-test was used for comparison between sides within each group. All groups presented symmetric muscular activity. The All-on-Four and dentate groups had a similar muscles surface electromyography (sEMG) contraction pattern, that is, a higher sEMG activity of masseter than temporalis muscles, differing (p ≤ .05) from those of denture group. Not one statistical difference was found between All-on-Four and dentate groups. The muscular function similarity of All-on-Four and dentate patients shows that this treatment concept may be considered as a good option for oral rehabilitation in edentulous patients. © 2013 Wiley Periodicals, Inc.

  20. [Computer aided design and rapid manufacturing of removable partial denture frameworks].

    PubMed

    Han, Jing; Lü, Pei-jun; Wang, Yong

    2010-08-01

    To introduce a method of digital modeling and fabricating removable partial denture (RPD) frameworks using self-developed software for RPD design and rapid manufacturing system. The three-dimensional data of two partially dentate dental casts were obtained using a three-dimensional crossing section scanner. Self-developed software package for RPD design was used to decide the path of insertion and to design different components of RPD frameworks. The components included occlusal rest, clasp, lingual bar, polymeric retention framework and maxillary major connector. The design procedure for the components was as following: first, determine the outline of the component. Second, build the tissue surface of the component using the scanned data within the outline. Third, preset cross section was used to produce the polished surface. Finally, different RPD components were modeled respectively and connected by minor connectors to form an integrated RPD framework. The finished data were imported into a self-developed selective laser melting (SLM) machine and metal frameworks were fabricated directly. RPD frameworks for the two scanned dental casts were modeled with this self-developed program and metal RPD frameworks were successfully fabricated using SLM method. The finished metal frameworks fit well on the plaster models. The self-developed computer aided design and computer aided manufacture (CAD-CAM) system for RPD design and fabrication has completely independent intellectual property rights. It provides a new method of manufacturing metal RPD frameworks.

  1. VINEGAR AS AN ANTIMICROBIAL AGENT FOR CONTROL OF Candida spp. IN COMPLETE DENTURE WEARERS

    PubMed Central

    Pinto, Telma Maria Silva; Neves, Ana Christina Claro; Leão, Mariella Vieira Pereira; Jorge, Antonio Olavo Cardoso

    2008-01-01

    The use of denture is known to increase the carriage of Candida in healthy patients, and the proliferation of Candida albicans strains can be associated with denture-induced stomatitis. The aim of this study was to evaluate the use of vinegar as an antimicrobial agent for control of Candida spp. in complete upper denture wearers. Fifty-five patients were submitted to a detailed clinical interview and oral clinical examination, and were instructed to keep their dentures immersed in a 10% vinegar solution (pH less than 3) overnight for 45 days. Before and after the experimental period, saliva samples were collected for detection of Candida, counting of cfu/mL and identification of species by phenotypical tests (germ tube formation, chlamidoconidia production, and carbohydrate fermentation and assimilation). The results were analyzed using Spearman's correlation and Student's t-test (p≤0.05). Candida yeasts were present in 87.3% of saliva samples before the treatment. A significant reduction was verified in CFU/mL counts of Candida after treatment. A positive correlation between Candida and denture stomatitis was verified, since the decrease of cfu/mL counts was correlated with a reduction in cases of denture stomatitis. Although it was not able to eliminate C. albicans, the immersion of the complete denture in 10% vinegar solution, during the night, reduced the amounts (cfu/mL) of Candida spp. in the saliva and the presence of denture stomatitis in the studied patients. PMID:19082396

  2. Influence of the width and cross-sectional shape of major connectors of maxillary dentures on the accuracy of speech production.

    PubMed

    Wada, Junichiro; Hideshima, Masayuki; Inukai, Shusuke; Matsuura, Hiroshi; Wakabayashi, Noriyuki

    2014-01-01

    To investigate the effects of the width and cross-sectional shape of the major connectors of maxillary dentures located in the middle area of the palate on the accuracy of phonetic output of consonants using an originally developed speech recognition system. Nine adults (4 males and 5 females, aged 24-26 years) with sound dentition were recruited. The following six sounds were considered: [∫i], [t∫i], [ɾi], [ni], [çi], and [ki]. The experimental connectors were fabricated to simulate bars (narrow, 8-mm width) and plates (wide, 20-mm width). Two types of cross-sectional shapes in the sagittal plane were specified: flat and plump edge. The appearance ratio of phonetic segment labels was calculated with the speech recognition system to indicate the accuracy of phonetic output. Statistical analysis was conducted using one-way ANOVA and Tukey's test. The mean appearance ratio of correct labels (MARC) significantly decreased for [ni] with the plump edge (narrow connector) and for [ki] with both the flat and plump edge (wide connectors). For [çi], the MARCs tended to be lower with flat plates. There were no significant differences for the other consonants. The width and cross-sectional shape of the connectors had limited effects on the articulation of consonants at the palate. © 2015 S. Karger AG, Basel.

  3. Effect of a new tension system, used in acrylic resin flasking, on the dimensional stability of denture bases.

    PubMed

    Consani, Rafael Leonardo Xediek; Domitti, Saide Sarckis; Consani, Simonides

    2002-09-01

    The pressure of final closure may be released when the flask is removed from the mechanical or pneumatic press and placed in the spring clamp. This release in pressure may result in dimensional changes that distort the denture base. The purpose of this study was to investigate differences between the dimensional stability of standardized simulated denture bases processed by traditional moist heat-polymerization and those processed by use of a new tension system. A metal master die was fabricated to simulate an edentulous maxillary arch without irregularities in the alveolar ridge walls. A silicone mold of this metallic die was prepared, and 40 stone casts were formed from the mold with type III dental stone. The casts were randomly assigned to 4 test groups (A-D) of 10 specimens each. A uniform denture base pattern was made on each stone cast with a 1.5-mm thickness of base-plate wax, measured with a caliper. The patterns were invested for traditional hot water processing. A polymethyl methacrylate dough was prepared and packed for processing. The flasks in groups A and B were closed with the traditional pressure technique and placed in spring clamps after final closure. The flasks in groups C and D were pressed between the metallic plates of the new tension system after the final closure. The group A and C flasks were immediately immersed in the water processing unit at room temperature (25 degrees +/- 2 degrees C). The unit was programmed to raise the temperature to 74 degrees C over 1 hour, and then maintained the temperature at 74 degrees C for 8 hours. The group B and D flasks were bench stored at room temperature (25 degrees +/- 2 degrees C) for 6 hours and were then subjected to the same moist heat polymerization conditions as groups A and C. All processed dentures were bench cooled for 3 hours. After recovery from the flasks, the base-cast sets were transversally sectioned into 3 parts (corresponding to 3 zones): (1) distal of the canines, (2) mesial of the first molars, and (3) mesial of the posterior palate). These areas had been previously established and standardized by use of a pattern denture in the sawing device to determine the sections in each base-cast set. Base-cast gaps were measured at 5 predetermined points on each section with an optical micrometer that had a tolerance of 0.001 mm. Collected data were analyzed with analysis of variance and Tukey's test. Denture bases processed with the new tension system exhibited significantly better base adaptation than those processed with traditional acrylic resin packing. Immediately after polymerization (Groups A and C), mean dimensional change values were 0.213 +/- 0.055 mm for the traditional packing technique and 0.173 +/- 0.050 mm for new tension system. After delayed polymerization (Groups B and D), the values were 0.216 +/- 0.074 mm for the traditional packing technique and 0.164 +/- 0.032 mm for new tension system. With both techniques, dimensional changes in the posterior palatal zone were greater (conventional = 0.286 +/- 0.038 mm; new system = 0.214 +/- 0.024 mm) than those elsewhere on the base-cast set. Within the limitations of this study, the new tension packing system was associated with decreased dimensional changes in the simulated maxillary denture bases processed with heat-polymerization.

  4. Prosthodontic maintenance of overdentures on zirconia implants: 1-year results of a randomized controlled trial.

    PubMed

    Osman, Reham B; Ma, Sunyoung

    2014-01-01

    The purpose of this study was to determine the prosthodontic outcomes of one-piece zirconia implants and their attachment systems in edentulous participants with maxillary and mandibular overdentures after 1 year of a randomized controlled trial. Random allocation of 24 edentulous participants (age range: 45 to 86 years) into titanium (control) or zirconia (test) groups using onepiece implants and a planned unsplinted prosthodontic design was performed. Four maxillary implants (one midpalatal; three anterior crestal) and three mandibular implants (one midsymphyseal; two bilateral distal) were conventionally loaded with the overdentures. Similar attachment systems were used throughout: ball abutment-type patrices (diameter: 2.25 to 3.1 mm as part of the one-piece implants) and custommade plastic matrices (with or without metal housings depending on the patrix size). Prosthodontic outcomes were documented during the first year of the clinical trial. Following three deaths and two dropouts, there were 19 participants who were available at the 1-year recall. Of these participants, 3 had early maxillary implant failure and had to be converted to conventional maxillary complete dentures opposing mandibular implant overdentures. There were 79 maintenance events, 34 in the titanium (control) group and 45 in the zirconia (test) group. Patrix loss occurred as a result of three zirconia implant fractures (one mandibular and two crestal maxillary implants). Maintenance events were principally the replacement of matrices and overdenture fracture. Although relines and replacement overdentures also occurred, overall there were no significant differences in prosthodontic maintenance between the control and test groups. A six-field prosthodontic-success analysis table showed no statistically significant difference between the two groups; however, 50% of participants in each group were allocated to the retreatment (repair) field, which produced a low prosthodontic success rate. Removable overdentures can be used on both one-piece titanium and zirconia implants with these attachment systems, due to no difference in prosthodontic maintenance and success. Before recommending routine use of a "metal-free" overdenture treatment option in clinical practice, consideration must be given to the success of the implants themselves.

  5. Simplified Prosthetic Rehabilitation of a Patient after Oral Cancer Removal

    PubMed Central

    Džakula, Nikola; Vojvodić, Denis

    2016-01-01

    The treatment of patients with oral cancer is complex: a multidisciplinary approach needs to be taken and maxillofacial and oral surgeons, an oncologist, a prosthodontist should be included, and a psychologist is often needed. This case report describes the prosthetic rehabilitation of a patient after surgical removal of oral cancer with obturator prosthesis. Resection cavity was located in central part of the hard palate and the condition belonged to Aramany class 3 maxillary defects. The two-step impression technique of denture bearing area was used and the resection of cavity was performed. A primary impression-the impression of denture bearing area was made using irreversible hydrocolloid material, while the second impression – the impression of resection cavity was made using condensation silicone material and obturator prosthesis framework. The obturator prosthesis replaced lost teeth, improved oral function and esthetics at minimal costs. PMID:27847400

  6. Prosthetic outcome, patient complaints, and nutritional effects on elderly patients with magnet-retained, implant-supported overdentures--a 1-year report.

    PubMed

    Khoo, Huan Ding; Chai, John; Chow, Tak Wah

    2013-01-01

    To study the changes in treatment outcomes of complete dentures and magnet-retained, implant-supported overdentures in a group of elderly patients. In this nonrandomized trial, 43 edentulous patients (14 men and 29 women) were fitted with complete dentures followed by implant-supported mandibular overdenture in a sequential model. Treatment outcomes used for analysis included objective assessment of denture quality (Woelfel's index), patient satisfaction, nutritional status, body mass index (BMI), and serum albumin level. The McNemar test was used to determine if significant differences in the Woelfel's index and nutritional status existed at different treatment phases. Repeated measures ANOVA and multiple pairwise comparison tests were used to analyze patient satisfaction. BMI status and serum albumin level at different treatment phases were analyzed with one-way ANOVA and Tukey post hoc test. At the 1-year follow-up, significant improvements were recorded for the objective assessment of denture quality and patient complaints (P < .05). No subject was found to be malnourished at pretreatment and in subsequent treatment phases. BMI and serum albumin level were not significantly different at different treatment phases (P > .05) CONCLUSIONS: The present study demonstrated that in elderly patients with stable health and nutritional status, complete dentures made in a university clinic brought about overall improvement in denture quality and reduction in denture complaint score. Insertion of mandibular implant-supported overdentures further improved the mandibular denture quality and reduced the mandibular denture complaint score. In this group of patients, no improvement in BMI, serum albumin value, and nutritional status were documented.

  7. Oral health-related quality of life in complete denture wearers depending on their socio-demographic background, prosthetic-related factors and clinical condition

    PubMed Central

    Perea, Carmen; Suárez-García, María J.; Del Río, Jaime; Torres-Lagares, Daniel; Montero, Javier

    2013-01-01

    Objectives: To investigate the differences in impact on oral health-related quality of life (OHRQoL) among complete denture wearers depending on their socio-demographic characteristics, prosthetic-related factors and oral status. Study Design: 51 patients aged 50-90 years treated, from 2005 to 2010, with at least one complete denture at the Department of Buccofacial Prostheses of the Complutense University (Madrid) were enrolled in this cross-sectional study. All of the participants answered the Oral Health Impact Profile (OHIP-14sp) questionnaire. The additive scoring method was used. The prevalence of impacts was calculated by using the occasional threshold (OHIP-14sp score≥2). Socio-demographic and prosthetic-related variables were gathered. Patients underwent clinical examination to assess their oral condition. Descriptive probes and Chi-Square tests were run (p≤0.05). Results: The predominant participants’ profile was that of a man with a mean age of 69 years wearing complete dentures in both the maxilla and the mandible. The prevalence of impact was 23.5%, showing an average score of 19±9.8. The most affected domains were “functional limitation” and “physical pain”, followed by “physical disability”. Minor impacts were recorded for the psychological and social subscales (“psychological discomfort”, “psychological disability”, “social disability” and “handicap”). The prosthesis’ location significantly influenced the overall patient satisfaction, the lower dentures being the less comfortable. Having a complete removable denture as antagonist significantly hampered the patient satisfaction. Patients without prosthetic stomatitis and those who need repairing or changing their prostheses, recorded significantly higher OHIP-14sp total scores. Conclusions: The use of conventional complete dentures brings negative impacts in the OHRQoL of elderly patients, mainly in case of lower prostheses that required reparation or substitution, with a removable total denture as antagonist. The prosthetic stomatitis in this study was always associated to other severe illness, which may have influenced the self-perceived discomfort with the prostheses, as those patients were daily medicated with painkillers. Key words:Oral Health Impact Profile (OHIP), oral health-related quality of life (OHRQoL), patient satisfaction, complete denture, elderly patients. PMID:23385509

  8. Evaluation of Sensibility Threshold for Interocclusal Thickness of Patients Wearing Complete Dentures

    PubMed Central

    Shala, Kujtim Sh.; Ahmedi, Enis F.; Tmava-Dragusha, Arlinda

    2017-01-01

    Objective The aim of this study was to evaluate sensibility threshold for interocclusal thickness in experienced and nonexperienced denture wearers after the insertion of new complete dentures. Materials and Methods A total of 88 patients with complete dentures have participated in this study. The research was divided into two experimental groups, compared with the previous experience prosthetic dental treatment. The sensibility threshold for interocclusal thickness was measured with metal foil with 8 μm thickness and width of 8 mm, placed between the upper and lower incisor region. Statistical analysis was performed using standard software package BMDP (biomedical statistical package). Results Results suggest that time of measurement affects the average values of the sensibility threshold for interocclusal thickness (F = 242.68, p = 0.0000). Gender appeared to be a significant factor when it interacted with time measurement resulting in differences in sensibility threshold for interocclusal thickness (gender: F = 9.84, p = 0.018; F = 4.83, p = 0.0003). Conclusion The sensibility threshold for interocclusal thickness was the most important functional adaptation in patient with complete dentures. A unique trait of this indicator is the progressive reduction of initial values and a tendency to reestablish the stationary state in the fifteenth week after dentures is taken off. PMID:28702055

  9. Edentulous patients' knowledge of dental hygiene and care of prostheses.

    PubMed

    de Castellucci Barbosa, Luciano; Ferreira, Manoela Rejane Maia; de Carvalho Calabrich, Carolina Freire; Viana, Aline Cavalcanti; de Lemos, Maria Catarina Lavigne; Lauria, Roberta Andrade

    2008-06-01

    The aim of this study was to analyse denture users' oral care habits with regard to the use of their prostheses. Rehabilitative treatment is only successful when patients are motivated and aware of correct prosthesis use and hygiene. Questionnaires were distributed to 150 complete denture users at the Federal University of Bahia School of Dentistry, the Esmeralda Natividade Health Center, the Bahian Science Development Foundation and a Salvador nursing home. The questionnaire included information on gender, age, length of prosthesis use, cleaning methods and materials, etc. The data were analysed using EpiInfo version 6 software. The chi-squared test was used for statistical analysis, with a significance level of 5%. Questionnaire results showed that 78% of the subjects, with an average age of 67.3 years, had used the same complete denture for over 5 years. 64% slept with their prostheses and 44% removed them from the mouth only for cleaning. None of the patients interviewed knew anything about brushes designed specifically for complete dentures. 37.3% had a restricted diet and 44% believed that a complete denture would last for more than 10 years. Within the limitations of this study, it was concluded that the edentulous patients surveyed had limited awareness of prosthetic hygiene and long-term oral care despite extended periods of denture use.

  10. Impact of implant-supported prostheses on nutritional status and oral health perception in edentulous patients.

    PubMed

    El Osta, Nada; El Osta, Lana; Moukaddem, Farah; Papazian, Tatiana; Saad, Robert; Hennequin, Martine; Rabbaa Khabbaz, Lydia

    2017-04-01

    Improvement of nutritional status and perception of oral health are supposed to be different with complete conventional denture or implant-supported fixed or removable prostheses. Since no study has been conducted in Lebanon, the aim of our study was to assess the nutritional status and oral heath related quality of life (OHRQoL) in totally edentulous patients after treatment with complete denture or implant supported-prostheses. This was an observational clinical prospective study. A convenient sample of Lebanese people aged 60 years or more was selected between September 2013 and July 2015 from the Departments of removable and fixed prosthesis at Saint-Joseph University of Beirut. The treatment options included complete denture, implant-supported complete denture and implant-supported fixed prostheses. Nutritional status and OHRQoL were assessed with the Mini-Nutritional Assessment Index (MNA) and the Geriatric Oral Health Assessment Index (GOHAI) respectively at Baseline (first visit before treatment), 2-3 weeks after treatment (t1), 3 months (t2) and 6 months (t3) after treatment. Fifty-one participants (mean age: 69.39 ± 7.164 years) were included. The results have shown an improvement over time in nutritional status and OHRQoL for all treatment groups. However, 2-3 weeks after treatment the number of participants at risk of malnutrition was higher with complete removable denture, intermediate with implant-supported complete denture and lower with implant-supported fixed prostheses (p-value = 0.049). Moreover, the mean GOHAI score was significantly lower over time with complete removable denture compared to implant-supported prostheses (p-value <0.05). Our study has shown an enhancement in the quality of life and the nutritional status for implant supported-prostheses compared to conventional removable dentures. Therefore, it is fundamental that dentists communicate with their patients about implant treatment to understand their expectations, to explain the outcomes and achieve the desired clinical result. Copyright © 2017 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.

  11. Comparative evaluation of border molding, using two different techniques in maxillary edentulous arches - An in vivo study

    PubMed Central

    Yarapatineni, Rameshbabu; Vilekar, Abhishek; Kumar, J Phani; Kumar, G Ajay; Aravind, Prasad; Kumar, P Anil

    2013-01-01

    Background: This study was undertaken to compare the retention between sectional border molding using low fusing greenstick compound and single step border molding using condensation silicone (putty) impression material in three stages- A. Immediately following border molding, B. After final impression and C. With the finished permanent denture base. Materials & Methods: In this study evaluation of retentive values of sectional border molding (Group I) (custom impression trays border molded with green stick compound ) and single step border molding (Group II) ( border molding with condensation silicone (putty) impression material ). In both techniques definitive wash impression were made with light body condensation silicone and permanent denture base with heat cure polymerization resin. Results: Group II was significantly higher (mean=8011.43) than Group I (mean=5777.43) in test-A. The t-value (1.5883) infers that there was significant difference between Group I and Group II (p =0.15). Group I was significantly higher (mean=6718.57) than Group II (mean=5224.29) in test -B. The t-value (1.6909) infers that there was significant difference between Group I and Group II (p=0.17). Group II was higher (mean=4025.14) than Group I (mean=3835.07) in test -C. The t-value was 0.1239. But it was found to be statistically insignificant (p=0.005). Conclusion: Within the limitation of this clinical study border molding custom tray with low fusing green stick compound provided similar retention as compared to custom impression tray with condensation silicone in permanent denture base. How to cite this article: Yarapatineni R, Vilekar A, Kumar JP, Kumar GA, Aravind P, Kumar PA. Comparative evaluation of border molding, using two different techniques in maxillary edentulous arches - An in vivo study. J Int Oral Health 2013; 5(6):82-7 . PMID:24453450

  12. Influence of guidance concept in complete dentures on oral health related quality of life - Canine guidance vs. bilateral balanced occlusion.

    PubMed

    Schierz, Oliver; Reissmann, Daniel

    2016-10-01

    To compare the impact of canine guided vs. bilateral balanced occlusion on oral health related quality of life (OHRQoL) as a patient-reported outcome measure. In this randomized single-blind crossover trial, 19 patients have been provided with new complete dentures in the maxilla and mandible. OHRQoL was assessed using the 49-item Oral Health Impact Profile (OHIP-49) before the start of the prosthodontic treatment (B), 3 months after insertion of the new dentures (T1), and 3 months after rework into the alternative concept (T2). Multilevel mixed-effect linear regression models were computed to determine the effect provided by the new set of dentures and the specific impact of the occlusal concept on OHRQoL using summary scores of the OHIP-49 and of a 19-items subset specific for edentulous patients (OHIP-EDENT). At baseline, participants' OHRQoL was substantially impaired indicated by an average OHIP-49 score of 42.1 points and an OHIP-EDENT score of 21.1 points. The effect of provision of a new set of complete dentures was a statistically significant decrease of 8.3 points (OHIP-49) and 4.0 points (OHIP-EDENT), respectively, representing a clinically relevant improvement in OHRQoL. When wearing dentures with bilateral balanced occlusion, participants showed on average 1.6 points higher OHIP-49 scores and 0.9 points higher OHIP-EDENT scores compared to canine guided dentures. This effect of the occlusal concept was neither statistically nor clinically significant. Both investigated occlusal concepts for complete dentures were comparable in their effect on patients' perceptions with none being considerably superior in terms of OHRQoL. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  13. A simplified method to reduce prosthetic misfit for a screw-retained, implant-supported complete denture using a luting technique and laser welding.

    PubMed

    Longoni, Salvatore; Sartori, Matteo; Davide, Roberto

    2004-06-01

    An important aim of implant-supported prostheses is to achieve a passive fit of the framework with the abutments to limit the amount of stress transfer to the bone-implant interface. An efficient and standardized technique is proposed. A definitive screw-retained, implant-supported complete denture was fabricated for an immediately loaded provisional screw-retained implant-supported complete denture. Precise fit was achieved by the use of industrial titanium components and the passivity, by an intraoral luting sequence and laser welding.

  14. Tensile bond strength between auto-polymerized acrylic resin and acrylic denture teeth treated with MF-MA solution.

    PubMed

    Thongrakard, Ticha; Wiwatwarrapan, Chairat

    2016-08-01

    This study evaluated the effect of chemical surface treatment using methyl formate-methyl acetate (MF-MA) solution on the tensile bond strength between acrylic denture teeth and auto-polymerized acrylic resin. Seventy maxillary central incisor acrylic denture teeth for each of three different brands (Yamahachi New Ace; Major Dent; Cosmo HXL) were embedded with incisal edge downwards in auto-polymerized resin in polyethylene pipes and ground with silicone carbide paper on their ridge lap surfaces. The teeth of each brand were divided into seven groups (n=10): no surface treatment (control group), MF-MA solution at a ratio of 25:75 (v/v) for 15 seconds, 30 seconds, 60 seconds, 120 seconds, 180 seconds, and MMA for 180 seconds. Auto-polymerized acrylic resin (Unifast Trad) was applied to the ground surface and polymerized in a pressure cooker. A tensile strength test was performed with a universal testing machine. Statistical analysis of the results was performed using two-way analysis of variance (ANOVA) and post-hoc Dunnett T3 test (α=.05). The surface treatment groups had significantly higher mean tensile bond strengths compared with the control group (P<.05) when compared within the same brand. Among the surface treatment groups of each brand, there were no significantly different tensile bond strengths between the MF-MA groups and the MMA 180 second group (P>.05), except for the Yamahachi New Ace MF-MA 180-second group (P<.05). 15-second MF-MA solution can be an alternative chemical surface treatment for repairing a denture base and rebonding acrylic denture teeth with auto-polymerized acrylic resin, for both conventional and cross-linked teeth.

  15. Reliability and validity of a questionnaire for self-assessment of complete dentures.

    PubMed

    Komagamine, Yuriko; Kanazawa, Manabu; Kaiba, Yoshinori; Sato, Yusuke; Minakuchi, Shunsuke

    2014-05-02

    Demand for complete denture treatment is expected to rise over several decades. However, to date, no questionnaire on complete dentures, as evaluated by edentulous patients, has been shown to be reliable and valid. This study sought to assess the reliability and validity of Patient's Denture Assessment (PDA), which provides a multidimensional evaluation of dentures among edentulous patients. Patients, who had new complete dentures fabricated at the University Hospital of Dentistry, Tokyo Medical and Dental University through 2009 to 2010, were enrolled. The reliability of the PDA was determined by examining internal consistency and test-retest reliability. Internal consistency for all of the question items and the six subscales was measured using Cronbach's α and average inter-item correlation coefficients among 93 participants. For 33 of these participants, test-retest reliability was determined at a 2 month-interval using the interclass correlation coefficients (ICCs) and 95% confidence interval for the summary scores and the six subscale scores. The PDA was validated in 93 participants by examining the difference in the summary score and the six subscale scores of the PDA before and after replacement with new dentures by the paired t-test. Ability to detect change was also tested in 93 patients using effect size. The Cronbach's α for the PDA ranged from 0.56 to 0.93. The average inter-item correlation coefficients ranged from 0.28 to 0.83. ICCs for the PDA ranged from 0.37 to 0.83. The paired t-test showed a significant difference between the summary score and the six subscale scores before and after replacement with new dentures (p < 0.05) and the effect size was 0.97. The PDA demonstrated good reliability by assessing internal consistency and test-retest reliability. In addition, the PDA demonstrated good validity by assessing discriminant validity. Thus, the PDA could help dentists obtain a detailed understanding of the patients' perceptions in using their dentures.

  16. Integrating 3D facial scanning in a digital workflow to CAD/CAM design and fabricate complete dentures for immediate total mouth rehabilitation

    PubMed Central

    Greven, Marcus; Wismeijer, Daniel

    2017-01-01

    PURPOSE To integrate extra-oral facial scanning information with CAD/CAM complete dentures to immediately rehabilitate terminal dentition. MATERIALS AND METHODS Ten patients with terminal dentition scheduled for total extraction and immediate denture placement were recruited for this study. The patients were submitted to a facial scanning procedure using the in-office PritiMirror scanner with bite registration records in-situ. Definitive stone cast models and bite records were subsequently submitted to a lab scanning procedure using the lab scanner (iSeries DWOS; Dental Wings). The scanned models were used to create a virtual teeth setup of a complete denture. Using the intra-oral bite records as a reference, the virtual setup was incorporated in the facial scan thereby facilitating a virtual clinical evaluation (teeth try-in) phase. After applying necessary adjustments, the virtual setup was submitted to a CAM procedure where a 5-axis industrial milling machine (M7 CNC; Darton AG General) was used to fabricate a full-milled PMMA immediate provisional prosthesis. RESULTS Total extractions were performed, the dentures were immediately inserted, and subjective clinical fit was evaluated. The immediate provisional prostheses were inserted and clinical fit, occlusion/articulation, and esthetics were subjectively assessed; the results were deemed satisfactory. All provisional prostheses remained three months in function with no notable technical complications. CONCLUSION Ten patients with terminal dentition were treated using a complete digital approach to fabricate complete dentures using CAD/CAM technology. The proposed technique has the potential to accelerate the rehabilitation procedure starting from immediate denture to final implant-supported prosthesis leading to more predictable functional and aesthetics outcomes. PMID:29142646

  17. Patient ratings of chewing ability from a randomised crossover trial: lingualised vs. first premolar/canine-guided occlusion for complete dentures.

    PubMed

    Heydecke, Guido; Akkad, Ahmed Shadi; Wolkewitz, Martin; Vogeler, Michael; Türp, Jens C; Strub, Joerg R

    2007-06-01

    Complex procedures involving a facebow transfer and the use of lingualised teeth are deemed to have a positive influence on the chewing ability with complete dentures. To determine if patients' ratings of their ability to chew depend on the method of complete denture fabrication. Edentulous patients (n = 20) participated in a within-subject crossover trial. Each patient received two sets of new complete dentures. One pair was manufactured based on intraoral tracing of centric relation and facebow transfer; semi-anatomical teeth with lingualised occlusion denture (LOD) were chosen. The second pair was made using a simplified procedure without facebow transfer; jaw relations were recorded with wax occlusion rims, and anatomical teeth with a first premolar/canine-guidance (CGD) were selected. The dentures were delivered in randomised order, and each was worn for 3 months. Three months after delivery, patients' ratings of each new prosthesis were recorded on visual analogue scales for their ability to chew seven index foods. Repeated measurements analysis of variance was performed to investigate possible carry-over effects accounting for confounding by treatment period. When comparing the two treatments, participants rated their ability to chew in general, to masticate carrots, hard sausage, steak and raw apple in particular, was significantly better with the CGD (anatomical teeth) than with the LOD (p < 0.05). Comprehensive methods for the fabrication of complete dentures including semi-anatomical lingualised teeth and a full registration do not seem to influence the perceived chewing ability, when compared with more simple procedures. Chewing ability for tough foods appears to benefit from the use of anatomical teeth.

  18. Prosthodontic Rehabilitation of Patients with Bell's Palsy: Our Experience.

    PubMed

    Rajapur, Anand; Mitra, Nirban; Prakash, V Jeevan; Rah, Sajad Ahmad; Thumar, Sagar

    2015-01-01

    Bell's palsy is an idiopathic unilateral lower motor neuron paresis or paralysis of the facial nerve of sudden onset. It involves loss of muscular control on the affected side of the face. This paper reports the prosthodontic management of patients with Bell's palsy and also describes a technique to stabilize the jaw movements in complete denture patients using interim dentures. A 65-year-old male edentulous patient and a 55-year-old female edentulous patient reported to the department of prosthodontics to get their missing teeth replaced. They both gave history of facial paralysis and were diagnosed for Bell's palsy. Interim training dentures with flat occlusal tables were fabricated first to correct and stabilize their mandibular movements. During initial 4 weeks, there was poor functioning of the interim dentures. Gradually by 8(th) week the patients started stabilizing the interim dentures and were functional. After observing the improvement when the patients had no pain and could stabilize and use the treatment dentures successfully, definitive complete dentures were fabricated. This case report presents a systematic approach to successively rehabilitate edentulous patients with Bell's palsy.

  19. Prosthodontic Rehabilitation of Patients with Bell’s Palsy: Our Experience

    PubMed Central

    Rajapur, Anand; Mitra, Nirban; Prakash, V Jeevan; Rah, Sajad Ahmad; Thumar, Sagar

    2015-01-01

    Bell’s palsy is an idiopathic unilateral lower motor neuron paresis or paralysis of the facial nerve of sudden onset. It involves loss of muscular control on the affected side of the face. This paper reports the prosthodontic management of patients with Bell’s palsy and also describes a technique to stabilize the jaw movements in complete denture patients using interim dentures. A 65-year-old male edentulous patient and a 55-year-old female edentulous patient reported to the department of prosthodontics to get their missing teeth replaced. They both gave history of facial paralysis and were diagnosed for Bell’s palsy. Interim training dentures with flat occlusal tables were fabricated first to correct and stabilize their mandibular movements. During initial 4 weeks, there was poor functioning of the interim dentures. Gradually by 8th week the patients started stabilizing the interim dentures and were functional. After observing the improvement when the patients had no pain and could stabilize and use the treatment dentures successfully, definitive complete dentures were fabricated. This case report presents a systematic approach to successively rehabilitate edentulous patients with Bell’s palsy. PMID:26668488

  20. Evaluation of the efficiency of denture cleaners for removing denture adhesives.

    PubMed

    Harada-Hada, Kae; Hong, Guang; Abekura, Hitoshi; Murata, Hiroshi

    2016-12-01

    We developed a new scoring index for assessing the removability of denture adhesives and evaluated the removal efficiency of denture cleaners. Although our understanding of the importance of denture care is increasing, little is known about the effectiveness and efficiency of denture cleaners on denture adhesives. Therefore, guidelines for proper cleaning are necessary. We used five denture cleaner solutions on two cream adhesives, one powder adhesive and one cushion adhesive. After immersion in the denture cleaners for a designated time, we evaluated the area of the sample plate still covered by denture adhesive. Cream adhesives were removed more completely after immersion in majority of the denture cleaners than in water. Powder adhesive was removed more quickly than cream adhesives. Cushion adhesive was not removed by immersion in either the denture cleaners or water control. Some denture cleaners could liquefy cream adhesives more than water, but these differences were not observed in case of powder and cushion adhesives. © 2015 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  1. Generation and evaluation of 3D digital casts of maxillary defects based on multisource data registration: A pilot clinical study.

    PubMed

    Ye, Hongqiang; Ma, Qijun; Hou, Yuezhong; Li, Man; Zhou, Yongsheng

    2017-12-01

    Digital techniques are not clinically applied for 1-piece maxillary prostheses containing an obturator and removable partial denture retained by the remaining teeth because of the difficulty in obtaining sufficiently accurate 3-dimensional (3D) images. The purpose of this pilot clinical study was to generate 3D digital casts of maxillary defects, including the defective region and the maxillary dentition, based on multisource data registration and to evaluate their effectiveness. Twelve participants with maxillary defects were selected. The maxillofacial region was scanned with spiral computer tomography (CT), and the maxillary arch and palate were scanned using an intraoral optical scanner. The 3D images from the CT and intraoral scanner were registered and merged to form a 3D digital cast of the maxillary defect containing the anatomic structures needed for the maxillary prosthesis. This included the defect cavity, maxillary dentition, and palate. Traditional silicone impressions were also made, and stone casts were poured. The accuracy of the digital cast in comparison with that of the stone cast was evaluated by measuring the distance between 4 anatomic landmarks. Differences and consistencies were assessed using paired Student t tests and the intraclass correlation coefficient (ICC). In 3 participants, physical resin casts were produced by rapid prototyping from digital casts. Based on the resin casts, maxillary prostheses were fabricated by using conventional methods and then evaluated in the participants to assess the clinical applicability of the digital casts. Digital casts of the maxillary defects were generated and contained all the anatomic details needed for the maxillary prosthesis. Comparing the digital and stone casts, a paired Student t test indicated that differences in the linear distances between landmarks were not statistically significant (P>.05). High ICC values (0.977 to 0.998) for the interlandmark distances further indicated the high degree of consistency between the digital and stone casts. The maxillary prostheses showed good clinical effectiveness, indicating that the corresponding digital casts met the requirements for clinical application. Based on multisource data from spiral CT and the intraoral scanner, 3D digital casts of maxillary defects were generated using the registration technique. These casts were consistent with conventional stone casts in terms of accuracy and were suitable for clinical use. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  2. Clinical trial for evaluation of Ricinus communis and sodium hypochlorite as denture cleanser

    PubMed Central

    BADARÓ, Maurício Malheiros; SALLES, Marcela Moreira; LEITE, Vanessa Maria Fagundes; de ARRUDA, Carolina Noronha Ferraz; OLIVEIRA, Viviane de Cássia; do NASCIMENTO, Cássio; de SOUZA, Raphael Freitas; PARANHOS, Helena de Freitas de Oliveira; SILVA-LOVATO, Cláudia Helena

    2017-01-01

    Abstract The development of opportunistic infections due to poor denture hygiene conditions justified the search for effective hygiene protocols for controlling denture biofilm. Objective This study evaluated Ricinus communis and sodium hypochlorite solutions in terms of biofilm removal ability, remission of candidiasis, antimicrobial activity, and participant satisfaction. Material and Methods It was conducted a controlled clinical trial, randomized, double-blind, and crossover. Sixty-four denture wearers with (n=24) and without candidiasis (n=40) were instructed to brush (3 times/day) and immerse their dentures (20 min/day) in different storage solutions (S1 / S2: 0.25% / 0.5% sodium hypochlorite; S3: 10% R. communis; S4: Saline).The trial period for each solution was seven days and a washout period of seven days was used before starting the use of another solution. The variables were analyzed at baseline and after each trial period. The biofilm of inner surfaces of maxillary dentures was disclosed, photographed, and total and dyed areas were measured (Image Tool software). The percentage of biofilm was calculated. Remission of candidiasis was assessed by visual scale and score were attributed. Antimicrobial activity was assessed by the DNA-Checkerboard hybridization method. Patient satisfaction was measured using a questionnaire. Results S1 (4.41±7.98%) and S2 (2.93±5.23%) were more effective then S3 (6.95±10.93%) in biofilm remotion(P<0.0001). All solutions were different from the control (11.07±11.99%). S3 was the most effective solution in remission of candidiasis (50%), followed by S1 (46%). Concerning antimicrobial action, S1/S2 were similar and resulted in the lowest microorganism mean count (P=0.04), followed by S3. No significant differences were found with patient’s satisfaction. Conclusions 10% R. communis and 0.25% sodium hypochlorite were effective in biofilm removal, causing remission of candidiasis and reducing the formation of microbial colonies in denture surfaces. All solutions were approved by patients. PMID:28678952

  3. Complete Dentures Fabricated with CAD/CAM Technology and a Traditional Clinical Recording Method.

    PubMed

    Janeva, Nadica; Kovacevska, Gordana; Janev, Edvard

    2017-10-15

    The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology into complete denture (CD) fabrication ushered in a new era in removable prosthodontics. Commercially available CAD/CAM denture systems are expected to improve upon the disadvantages associated with conventional fabrication. The purpose of this report is to present the workflow involved in fabricating a CD with a traditional clinical recording method and CAD/CAM technology and to summarize the advantages to the dental practitioner and the patient.

  4. [Application of individual light-curing resin tray as edge plastic material in complete denture modulo].

    PubMed

    Chai, Mei; Tang, Xuyan; Liang, Guangku

    2015-12-01

    To investigate clinical effect of individual light-curing resin tray as edge plastic material in complete denture modulo.
 A total of 30 patients with poor condition for alveolar ridge of mandible were chosen individual tray with individual light-curing resin tray for material edge shaping or traditional individual impression tray for edge shaping cream to produce complete denture. The operability, questionnaire about denture retention, comfort, mucosal cases and chewing function in the process of shaping the edge were investigated three months later after wearing dentures.
 There was no significant difference in retention, comfort, mucosa and the chewing function between the two mandibular denture impression methods. However, the patients with individual light-curing resin tray as edge shaping material felt better in the process than that in the patients with die-cream as the edge shaping material (P<0.05). Furthermore, the manipulation with individual light-curing resin tray as edge shaping material is easy for doctor.
 Although the clinical effect of Individual light-curing resin tray material as the edge shaping material is equal to that of impression cream, it saves time and human resource. Moreover, it is more acceptable for the patients and thus it can be spread in clinics.

  5. Biting and chewing in overdentures, full dentures, and natural dentitions.

    PubMed

    Fontijn-Tekamp, F A; Slagter, A P; Van Der Bilt, A; Van 'T Hof, M A; Witter, D J; Kalk, W; Jansen, J A

    2000-07-01

    It has been suggested that the provision of dental implants can improve the oral function of subjects with severely resorbed mandibles, possibly restoring function to the level experienced by satisfied wearers of conventional complete dentures. Nevertheless, a quantitative comparison has never been made and can be drawn from the literature only with difficulty, since studies differ greatly in methodology. To make such a comparison, we measured bite force and chewing efficiency by using identical methods in subjects with overdentures, complete full dentures, and natural dentitions. Our results indicated that bite forces achieved with overdentures on dental implants were between those achieved with artificial and natural dentitions. Chewing efficiency was significantly greater than that of subjects with full dentures (low mandible), but was still lower than that of subjects with full dentures (high mandible) and overdentures on bare roots. Differences in the height of the mandible revealed significant differences in chewing efficiency between the two full-denture groups. Furthermore, subjects with a shortened dental arch exerted bite forces similar to those of subjects with a complete-natural dentition, but their chewing efficiency was limited due to the reduced occlusal area. For all groups combined, a significant correlation was found between maximum bite force and chewing efficiency. Nearly half of the variation in chewing efficiency was explained by bite force alone.

  6. Conventional Complete Denture in Patients with Ectodermal Dysplasia

    PubMed Central

    Vilanova, Larissa Soares Reis; Sánchez-Ayala, Alfonso; Ribeiro, Giselle Rodrigues; Campos, Camila Heitor; Farias-Neto, Arcelino

    2015-01-01

    Ectodermal dysplasia is described as heritable conditions that involve anomalies of structures derived from the ectoderm, including hypodontia. In the cases of edentulous young patients, who did not finish their craniofacial growth, treatment with conventional complete denture is a suitable alternative. The aim of this study was to report a case of mandibular edentulism treated with conventional complete denture in a thirteen-year-old patient diagnosed with hidrotic ectodermal dysplasia. Typical features, such as frontal bossing, depressed nasal bridge, protuberant lips, scarce hair, and brittle nails, were visualized during the extraoral examination. The intraoral inspection and radiographic analysis revealed oligodontia, dental malformation, and prolonged retention of deciduous teeth at maxilla and total edentulism at mandible. A conventional complete denture was planned and constructed following the same steps of technique as recommended in adults. Although this option is not a definitive treatment, the patient and his parents were satisfied with his improvement in chewing and speech, as well as with the aesthetic benefits. PMID:26425372

  7. [Correlation of psychoemotional status and adaptation to complete dentures].

    PubMed

    Barkan, I Yu; Stafeev, A A; Repin, V S

    2015-01-01

    Patients with full adentia are characterized by the formation of specific psycho-emotional status. Rational psychotherapeutic support of these patients largely determines the efficiency of dental prosthetic treatment. At the same time, the definition of mental and emotional status is not included in the diagnostic examination protocol. Considering the above the purpose of the study was to evaluate mental and emotional status of patients receiving complete dentures. Prosthetic rehabilitation of 30 patients with complete teeth loss was performed and clinical evaluation and evaluation of mental and emotional status were carried out before and after treatment. Patients with negative experiences of prosthetics showed a higher level of personal and situational anxiety. There was correlation of adaptation to removable dentures and the patient's personality traits. It is determined that emotional instability during treatment tends to decrease affecting the timing of adaptation to complete dentures. It is noted that patients with repeated prosthetics have earlier recovery of coordination ability of the masticatory muscles.

  8. Clinical evaluation of three denture cushion adhesives by complete denture wearers.

    PubMed

    Koronis, Spyros; Pizatos, Evangelos; Polyzois, Gregory; Lagouvardos, Panagiotis

    2012-06-01

    The aim of this study was the clinical evaluation of three denture cushion adhesives and whether the results were correlated to Kapur Index for denture-supporting tissues. Various types of denture adhesives are used among denture patients. However, information on the clinical behaviour of denture cushions is limited. Thirty edentulous patients had their denture-supporting tissues scored by Kapur Index and their old dentures replaced. They received three brands of denture cushion adhesives (Fittydent(®) , Protefix(®) and Seabond(®)) and were instructed to use them in a sequence according to the group they were randomly assigned to. Each brand of adhesive was used for 48 h on the lower denture according to the manufacturer's suggestions. After each brand was used, participants spent 24 h without applying any sort of adhesive. Finally, a questionnaire evaluating and comparing the performance of each brand was filled out. Denture adhesives generally improved patient satisfaction and masticatory ability, especially in participants with poor Kapur Index and those who reported a poor retention of their old dentures. Fittydent(®) was the most preferred adhesive, showing the best retention and the longest duration of its effect, but also reported as difficult to remove from the denture-bearing area. © 2010 The Gerodontology Society and John Wiley & Sons A/S.

  9. Oral malodor and removable complete dentures in the elderly.

    PubMed

    Nalcaci, Rana; Baran, Ilgi

    2008-06-01

    The objectives of this study were to assess oral malodor in patients with removable complete dentures and analyze its association with age, sex, subjective oral dryness, burning mouth, tongue coating, and overnight denture wear in elderly subjects. The study comprised 105 complete denture wearers (56 male, 49 female) between the ages of 50 and 78 from the province of Kirikkale in the Central Anatolia Region of Turkey. Oral malodor was assessed using a portable sulfide monitor. Participants were given a self-administered, structured questionnaire. Baseline and final volatile sulfur compound (VSC) levels and tongue-coating scores (TCS) were measured. Analysis included frequency, cross-tabulations, ANOVA, and independent sample and paired t tests. Odds ratios of VSC-related factors were also calculated. A P value less than .05 was considered statistically significant. There was no significant correlation found between age, gender, smoking, existence of a medical condition, or regular use of medication and VSC levels in mouth air (P > .05). However, educational level (P < .05), oral dryness (P < .05), burning mouth (P < .05), overnight denture wear (P < .01), and TCS (P < .001) were found to be significantly correlated with VSC levels. Significant differences were also found between baseline and final measurements of both VSC levels and TCS (P < .01). This study found the accumulation of bacterial plaque on the tongue, oral dryness, burning mouth, overnight denture wear, and lower educational levels to be significantly related to oral malodor. Following tongue care maintenance and overnight removal of dentures, patients' oral malodor levels decreased significantly.

  10. Elders with implant overdentures: a 22-year clinical report.

    PubMed

    Alsabeeha, Nabeel H M

    2012-09-01

    To report on the long-term survival and prosthodontic maintenance of two edentulous adults with mandibular overdentures supported by hydroxyapatite (HA)-coated implants. Mandibular implant overdentures are a successful treatment option with positive impact on the quality of life of elderly edentulous adults. Long-term survival of the implants requires continued rigorous prosthodontic maintenance. Two elderly edentulous adults with mandibular overdentures supported by 2 HA-coated implants were presented for prosthodontic rehabilitation after 22 years of placement. The implants were osseo-integrated and surviving at presentation based on accepted criteria. The mandibular implant overdentures suffered recurrent loss of retention and stability. Prosthodontic treatment involving the replacement of defective attachment systems and construction of new sets of mandibular implant overdentures opposing complete maxillary dentures is presented. The long-term survival of mandibular 2-implant overdentures requires continued prosthodontic maintenance. A conservative approach in the rehabilitation of two older edentulous adults with mandibular 2-implant overdentures was described including proper selection of attachment systems. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

  11. Denture reconstruction of the edentulous upper jaw in cleft palate using implants--clinical report.

    PubMed

    Dostálová, T; Holakovský, J; Bartonová, M; Seydlová, M; Smahel, Z

    2007-01-01

    Early prosthodontic therapy (usually at around 18 years of age) often leads to early loss of teeth and in extreme cases to complete loss of dentition at between 40 and 50 years of age. This report describes the clinical features of two middle-aged cleft patients. Edentulous maxilla with cleft defect was treated with 6 implants supported by fixed appliance. Treatment of the whole dental arch on the basis of implants is currently frequently used as it provides a possibility of thorough functional and aesthetic therapy to a patient. The biomechanics of the reconstruction enables individual adjustment of the shape of the dental arch. The problem in cleft patients involves other diameter relations in the dental arch caused by the defect alone or also by affecting the growth of the maxillary segment by surgery. A potentially removable framework is therefore the main method of choice because the position of the implants must be prosthetically modified.

  12. Complete denture base assessments using holograms: dimensional alterations after different activation methods

    NASA Astrophysics Data System (ADS)

    Dughir, Ciprian; Popovschi, Ana Maria; Cojocariu, Andreea Codruta; Topala, Florin Ionel; Negrutiu, Meda Lavinia; Sinescu, Cosmin; de Sabata, Aldo; Duma, Virgil-Florin

    2016-03-01

    Holography is a well-developed method with a large range of applications, including dentistry. This study uses holographic methods for the study of total dental prosthesis. The issue is that the transformation of wax denture base in polymethylacrylate causes dimensional alterations and retractions in the final dental constructs. These could cause the failure of the stability of the complete denture in the oral cavity. Thus, the aim of this study is to determine and to compare using holography, total prosthesis obtained using three different manufacturing methods: pressing, injection, and polymerization. Each of the three types of dentures thus produced were recorded over the previously wax complete base holographic plates. The dimensional alterations that appear after using the different activation methods were thus determined. The most significant modification was remarked in the custom press technology, while the smallest variations were detected in the injection alternative.

  13. A randomised controlled trial of complete denture impression materials.

    PubMed

    Hyde, T P; Craddock, H L; Gray, J C; Pavitt, S H; Hulme, C; Godfrey, M; Fernandez, C; Navarro-Coy, N; Dillon, S; Wright, J; Brown, S; Dukanovic, G; Brunton, P A

    2014-08-01

    There is continuing demand for non-implant prosthodontic treatment and yet there is a paucity of high quality Randomised Controlled Trial (RCT) evidence for best practice. The aim of this research was to provide evidence for best practice in prosthodontic impressions by comparing two impression materials in a double-blind, randomised, crossover, controlled, clinical trial. Eighty-five patients were recruited, using published eligibility criteria, to the trial at Leeds Dental Institute, UK. Each patient received two sets of dentures; made using either alginate or silicone impressions. Randomisations determined the order of assessment and order of impressions. The primary outcome was patient blinded preference for unadjusted dentures. Secondary outcomes were patient preference for the adjusted dentures, rating of comfort, stability and chewing efficiency, experience of each impression, and an OHIP-EDENT questionnaire. Seventy-eight (91.8%) patients completed the primary assessment. 53(67.9%) patients preferred dentures made from silicone impressions while 14(17.9%) preferred alginate impressions. 4(5.1%) patients found both dentures equally satisfactory and 7 (9.0%) found both equally unsatisfactory. There was a 50% difference in preference rates (in favour of silicone) (95%CI 32.7-67.3%, p<0.0001). There is significant evidence that dentures made from silicone impressions were preferred by patients. Given the strength of the clinical findings within this paper, dentists should consider choosing silicone rather than alginate as their material of choice for secondary impressions for complete dentures. ISRCTN 01528038. This article forms part of a project for which the author (TPH) won the Senior Clinical Unilever Hatton Award of the International Assocation for Dental Research, Capetown, South Africa, June 2014. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. Electromyographic evaluation of masseter and anterior temporalis muscles in rest position of edentulous patients with temporomandibular disorders, before and after using complete dentures with sliding plates.

    PubMed

    Zuccolotto, Maria Cristina Candelas; Vitti, Mathias; Nóbilo, Krunislave Antônio; Regalo, Simone Cecílio Hallak; Siéssere, Selma; Bataglion, César

    2007-06-01

    This study was performed with the purpose of investigating electromyographic (EMG) activity of the anterior temporalis and masseter muscles in edentulous individuals with temporomandibular disorder (TMD), before and after using sliding plates on complete dentures in the mandibular rest position. Edentulous patients may present TMD, which is characterised by pain in temporomandibular joints, masticatory and neck muscles, uncoordinated and limited mandible movements, joint sounds and an altered occlusal relationship. It is imperative to offer treatment in order to re-establish stomatognathic system structures before submitting the individual to any definitive restorative treatment. The patients were edentulous for at least 10 years. EMG recordings were made before the insertion of the dentures (0 months) and also after using the sliding plates at the fourth month, 9th month and 12th month, using computerised electromyography K6-I/ EMG Light Channel Surface. EMG evaluations of the muscles were performed under the following clinical conditions: rest position with dentures (R1), rest position without dentures (R2), rest position with dentures post-activity (chewing) (R3), rest position without dentures post-activity (chewing) (R4). All patients obtained remission of muscular fatigue and reduced pain in stomatognathic system structures. Temporalis muscle showed significant increase in EMG activity compared with initial values (p < 0.01). Masseter muscles showed significantly lower mean values (p < 0.01) compared with initial values. The sliding plates allowed the process of neuromuscular deprogramming, contributing to muscular balance of the masticatory system, and are therefore indicated to be used before the fabrication of definitive complete dentures in patients with TMD.

  15. Factors affecting the distribution and prevalence of oral mucosal lesions in complete denture wearers.

    PubMed

    Mandali, Gamze; Sener, Işıl Damla; Turker, Sebnem Begum; Ulgen, Hasan

    2011-06-01

    To determine the frequency of the oral lesions related to gender, age, the length of time of denture usage, education level and economic status. The 153 patients with old complete dentures (CD) were asked to participate in the investigation. The subjects (76 male and 77 female) were 37-85 years of age with a mean age of 61.8 ± 9.8 years. Education, economic status and age factors were estimated in subgroups. The data obtained were evaluated by one-way anova, Mann-Whitney U-test, Kruskal-Wallis test, Student's t-test and chi-squared test. The level of statistical significance was set at p<0.05. The patients who had denture stomatitis and traumatic ulcers were statistically significantly older than the ones who did not have these lesions (p<0.05). Based on the length of denture usage, patients who had a flabby ridge, fibrous inflammatory hyperplasia, traumatic ulcers (p<0.01) and denture stomatitis (p<0.05) were using their dentures statistically significantly longer than the ones who had healthy tissues. The CD wearers should be advised to visit their dentist regularly to prevent oral mucosal lesions due to the changing supporting tissues during the length of denture usage and to improve their quality of life. © 2010 The Gerodontology Society and John Wiley & Sons A/S.

  16. Setting up of teeth in the neutral zone and its effect on speech

    PubMed Central

    Al-Magaleh, Wafa’a Radwan; Swelem, Amal Ali; Shohdi, Sahar Saad; Mawsouf, Nadia Mohamed

    2011-01-01

    Rational goals for denture construction are basically directed at the restoration of esthetics and masticatory function and the healthy preservation of the remaining natural tissues. Little concern has been given to the perfection and optimization of the phonetic quality of denture users. However, insertion of prosthodontic restorations may lead to speech defects. Most such defects are mild but, nevertheless, can be a source of concern to the patient. For the dental practitioner, there are few guidelines for designing a prosthetic restoration with maximum phonetic success. One of these guidelines involves the setting up of teeth within the neutral zone. The aim of this study was to evaluate, subjectively and objectively, the effect on speech of setting up teeth in the neutral zone. Three groups were examined: group I (control) included 10 completely dentulous subjects, group II included 10 completely edentulous patients with conventional dentures, and group III included the same 10 edentulous patients with neutral zone dentures. Subjective assessment included patient satisfaction. Objective assessment included duration taken for recitation of Al-Fateha and acoustic analysis. Subjectively, patients were more satisfied with their neutral zone dentures. Objectively, speech produced with the neutral zone dentures was closer to normal than speech with conventional dentures. PMID:23960527

  17. A radiographic template for a two-implant mandibular overdenture using the patient’s existing denture

    PubMed Central

    Huynh-Ba, G; Alexander, P; Vargas, A; Vierra, M; Oates, TW

    2012-01-01

    This article introduces a technique for modifying an existing mandibular complete denture for use as a radiographic template with a radiopaque light-activated calcium hydroxide (Ca(OH)2) preparation. This allows prosthetically-driven treatment planning and surgical placement of 2 implants to support the existing mandibular denture. PMID:23328197

  18. Comparison of immediate complete denture, tooth and implant-supported overdenture on vertical dimension and muscle activity

    PubMed Central

    Shah, Farhan Khalid; Gebreel, Ashraf; Elshokouki, Ali hamed; Habib, Ahmed Ali

    2012-01-01

    PURPOSE To compare the changes in the occlusal vertical dimension, activity of masseter muscles and biting force after insertion of immediate denture constructed with conventional, tooth-supported and Implant-supported immediate mandibular complete denture. MATERIALS AND METHODS Patients were selected and treatment was carried out with all the three different concepts i.e, immediate denture constructed with conventional (Group A), tooth-supported (Group B) and Implant-supported (Group C) immediate mandibular complete dentures. Parameters of evaluation and comparison were occlusal vertical dimension measured by radiograph (at three different time intervals), Masseter muscle electromyographic (EMG) measurement by EMG analysis (at three different positions of jaws) and bite force measured by force transducer (at two different time intervals). The obtained data were statistically analyzed by using ANOVA-F test at 5% level of significance. If the F test was significant, Least Significant Difference test was performed to test further significant differences between variables. RESULTS Comparison between mean differences in occlusal vertical dimension for tested groups showed that it was only statistically significant at 1 year after immediate dentures insertion. Comparison between mean differences in wavelet packet coefficients of the electromyographic signals of masseter muscles for tested groups was not significant at rest position, but significant at initial contact position and maximum voluntary clench position. Comparison between mean differences in maximum biting force for tested groups was not statistically significant at 5% level of significance. CONCLUSION Immediate complete overdentures whether tooth or implant supported prosthesis is recommended than totally mucosal supported prosthesis. PMID:22737309

  19. A Survey of Removable Partial Denture (RPD) Retentive Elements in Relation to the Type of Edentulism and Abutment Teeth Found in Commercial Laboratories, Athens, Greece

    PubMed Central

    Sotiriou, Michael; Zissis, Alcibiades

    2014-01-01

    Objective The aim of this survey was to record removable partial denture (RPD) retentive elements and abutment teeth in partially edentulous patients, identified in commercial laboratories in Athens, Greece. Material and Methods 628 master casts with the corresponding cast metal frameworks used in the construction of RPDs were evaluated. Casts were photographed to identify the number and position of existing teeth, the partial edentulism class and the retentive elements. Prevalence tables and the x2 test were used for the statistical analysis of the collected data (α=.05). Results There were 276 maxillary (43.9%) and 352 (56.1%) mandibular casts. Maxillary edentulism entailed almost a total absence of right third molars in 96.7% and left third molars 96.0% of casts, with lower rates for the first and second molars. Edentulism in the posterior mandible presented a similar pattern. The most profound findings concerning retentive elements were: 91.9% of the retainers used were clasps and the remaining 8.1% were attachments. Of the clasps used, 48.9% were of the Roach Τ type, a finding more common in Kennedy Class I as compared to other Kennedy Classes (p<0.01). The circumferential clasps accounted for 19.3% of the total clasps used, and it was less frequently presented (8.8%) in Kennedy I Classes (p<0.01). Conclusions Roach clasps were used in the majority of cases whereas RPI clasps and attachments were rarely used. PMID:27688367

  20. Studies on adaptation to complete dentures. Part II: Oral stereognosis and tactile sensibility.

    PubMed

    Müller, F; Link, I; Fuhr, K; Utz, K H

    1995-10-01

    High oral perception is thought to contribute to poor adaptation to new dentures. The aim of this study was to evaluate the oral stereognosis and tactile sensibility in edentate subjects and relate these to patient age and capability of adaptation to new prostheses. A total of 67 patients were provided with new complete dentures 2-3 weeks before the experiment. In 54 subjects, the oral stereognosis was evaluated by 12 different test-pieces, which were placed unseen on the tongue and had to be recognized. In 38 patients, the oral tactile sensibility was determined in the premolar area using copper foils. The capability of adaptation was evaluated by a questionnaire. Denture retention was assessed by clinical examination. The number of correctly identified test-pieces and the average identification time were related to the age, but no relation was found to patients' capability of adaptation. The tactile sensibility was found to be impaired with age and diminished capability of adaptation. Both adaptation and oral tactile sensibility were significantly lower in subjects with poor lower-denture retention. In conclusion, the results cannot support a relationship between high oral stereognosis and adaptation problems. However, good denture retention facilitates the adaptation process.

  1. [Study of the appearance difference of lower complete denture between functional and anatomic impression techniques].

    PubMed

    Zhong, Qun; Wu, Xue-yin; Shen, Qing-yi; Shen, Qing-ping

    2012-04-01

    To compare the difference in oblique external ridge, oblique internal ridge and alveolar process crest of lower complete denture base made through functional impression and anatomic impression techniques. Fifteen patients were chosen to treat with two kinds of complete dentures through functional impression and anatomic impression technique respectively. 3D laser scanner was used to scan the three-dimensional model of the denture base and the differences of the surface structural between two techniques in alveolar process crest, external and internal oblique ridges were analyzed, using paired t test with SPSS 12.0 software package. Between the two techniques, there were significant differences in the areas of internal and external oblique ridge(P<0.01); there was no significant difference in the main support areas(P>0.05). The results explain why there is less tenderness when functional impression technique is applied. The differences measured also indicate that sufficient buffering should be made in external and internal oblique ridge areas in clinic.

  2. Mandibular implant-supported overdentures: attachment systems, and number and locations of implants--Part I.

    PubMed

    Warreth, Abdulhadi; Alkadhimi, Aslam Fadel; Sultan, Ahmed; Byrne, Caroline; Woods, Edel

    2015-01-01

    The use of dental implants in replacing missing teeth is an integral part of restorative dental treatment. Use of conventional complete dentures is associated with several problems such as lack of denture stability, support and retention. However, when mandibular complete dentures were used with two or more implants, an improvement in the patients' psychological and social well-being could be seen. There is general consensus that removable implant-supported overdentures (RISOs) with two implants should be considered as the first-choice standard of care for an edentulous mandible. This treatment option necessitates the use of attachment systems that connect the complete denture to the implant. Nevertheless, each attachment system has its inherent advantages and disadvantages, which should be considered when choosing a system. The first part of this article provides an overview on options available to restore the mandibular edentulous arch with dental implants. Different types of attachment systems, their features and drawbacks are also reviewed.

  3. Three-year clinical outcome of single implant-retained mandibular overdentures--results of preliminary prospective study.

    PubMed

    Harder, Sönke; Wolfart, Stefan; Egert, Christopher; Kern, Matthias

    2011-10-01

    The aim of this preliminary prospective study was to evaluate the clinical outcome, the oral health-related quality of life (OHRQoL), and the subjective chewing ability of patients with mandibular complete dentures retained by a single implant placed in the mandible midline. Patients wearing complete dentures were treated with a single implant in the mandible, followed by relining of the dentures and incorporation of ball attachments for implant retention. Implant outcome, prosthodontic maintenance, subjective chewing ability, and the oral health impact profile of the patients were assessed at baseline and at four weeks after connecting the denture and implant. Eleven patients were enrolled in this investigation, and the mean observation period was 43.4 months (minimum period: 35, maximum period: 52 months). No implants were lost during observation period, but four dentures needed repair because of the fracture of the denture base in the midline area. A significant improvement was observed in the OHRQoL of the patients after the attachment of the mandibular dentures with a single midline implant. Furthermore, the subjective chewing ability of the patients was significantly improved after implant connection. Within the limitations of this preliminary prospective clinical study, single implant-supported mandibular overdentures were a successful treatment option for older edentulous patients who showed improvements in their OHRQoL and chewing ability. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Contour of lingual surface in lower complete denture formed by polished surface impression.

    PubMed

    Heo, Yu-Ri; Kim, Hee-Jung; Son, Mee-Kyoung; Chung, Chae-Heon

    2016-12-01

    The aim of this study was to analyze the shapes of lingual polished surfaces in lower complete dentures formed by polished surface impressions and to provide reference data for use when manufacturing edentulous trays and lower complete dentures. Twenty-six patients with mandibular edentulism were studied. After lower wax dentures were fabricated, wax was removed from the lingual side of the wax denture and a lingual polished surface impression was obtained with tissue conditioner. The definitive denture was scanned with a three-dimensional scanner, and scanned images were obtained. At the cross-sections of the lingual frenum, lateral incisors, first premolars, first molars, and anterior border of the retromolar pads, three points were marked and eight measurements were taken. The Kruskal-Wallis test and a post hoc analysis with the Mann-Whitney test were performed. Each patient showed similar values for the same areas on the left and right sides without a statistically significant difference. The height of the contour of the lingual polished surface at the lingual frenum was halfway between the occlusal plane and lingual border, it moved gradually in a downward direction. The angle from the occlusal plane to the height of the contour of the lingual polished surface was increased as it progressed from the lingual frenum towards the retromolar pads. The shape of the mandibular lingual polished surface was convex at the lingual frenum, lateral incisors and gradually flattened towards the first molars and retromolar pads.

  5. The effect of number and distribution of unsplinted maxillary implants on the load transfer in implant-retained maxillary overdentures: an in vitro study.

    PubMed

    Damghani, Sahar; Masri, Radi; Driscoll, Carl F; Romberg, Elaine

    2012-06-01

    There is little information as to how the number and distribution of implants affect the amount of load transmitted to the palate in implant-retained maxillary overdentures. The purpose of this study was to evaluate the effect of the number and distribution of dental implants on the load transmitted to the palate. Eight implant analogues were placed in a replica of an average sized edentulous maxilla corresponding to the position of canines, first and second premolars, and first molars. The anteroposterior distance between the centers of implants in each quadrant was 8 mm. Fifteen denture bases were fabricated to fit the edentulous maxilla analogue. The denture bases were attached to the oral analogue using 6 different configurations of attachments (6 groups): Either no Locator attachments were used (control group), or the 2 most anterior attachments were attached, or 4 implants were engaged with a distance of 8, 16, or 24 mm between the centers of implants on left and right side, and finally, when all 8 attachments were activated. A force-measuring sensor was used to measure the force transmitted to the palate when a static force of 245 N was applied on the occlusal rims of the denture bases. Data (Newtons) were analyzed using 1-way ANOVA and Tukey's HSD test α=.05). The mean (SD) amount of force measured on the palate when the overdentures were supported by 4 Locator attachments; [49.84 (26.52) at 8 mm spacing], [24.42 (15.05) at 16 mm spacing], [35.66 (22.94) at 24 mm spacing] was significantly lower than when no attachments [90.98 (20.20), control], or when 2 Locator attachments were used [76.07 (27.63)] (P<.001). When the overdentures were supported by 8 Locator attachments, the force measured on the palate [20.67(16.06) N] was significantly lower than that for the control group (P<.001), overdentures supported by 2 Locator attachments (P<.001), and overdentures supported by 4 Locator attachments when the distance between the anterior and posterior implants was 8 mm P=.006). The distribution of implants had a significant effect on the force measured on the palate of the oral analogue in overdentures retained by Locator attachments. When the distance between the 4 implants was 16 or more mm, the load was not significantly lower than the 8 implant design, suggesting that the palate of a 4 implant-retained overdenture with a distance of 16 mm or more, does not contribute significantly to the load transfer to underlying hard palate in the in vitro analogue evaluated. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  6. Effects of glass fiber mesh with different fiber content and structures on the compressive properties of complete dentures.

    PubMed

    Yu, Sang-Hui; Cho, Hye-Won; Oh, Seunghan; Bae, Ji-Myung

    2015-06-01

    No study has yet evaluated the strength of complete dentures reinforced with glass fiber meshes with different content and structures. The purpose of this study was to compare the reinforcing effects of glass fiber mesh with different content and structures with that of metal mesh in complete dentures. Two types of glass fiber mesh were used: SES mesh (SES) and glass cloth (GC2, GC3, and GC4). A metal mesh was used for comparison. The complete dentures were made by placing the reinforcement 1 mm away from the tissue surface. A control group was prepared without any reinforcement (n=10). The compressive properties were measured by a universal testing machine at a crosshead speed of 5 mm/min. The results were analyzed with the Kruskal-Wallis test and the Duncan multiple range test (α=.05). The fracture resistance of the SES group was significantly higher than that of the control, GC4, and metal groups (asymptotic P=.004), but not significantly different from the GC2 and GC3 groups. The toughness of the SES and GC3 groups was significantly higher than that of the others (asymptotic P<.001), but not significantly different from that of the GC4 group. SES and GC3, which have different structures but similar volume content, were the most effective in reinforcing complete dentures. The content of the glass fiber mesh seemed more important than the structures. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  7. An intervention study to test Locker's conceptual framework of oral health in edentulous elders.

    PubMed

    Yamaga, Eijiro; Sato, Yusuke; Minakuchi, Shunsuke

    2018-06-01

    To test a previously described conceptual framework of oral health in edentulous elders using an intervention study that included complete denture replacement. Confirmatory factor analysis (CFA) was also conducted to substantiate construct validity. To date, the model proposed by Locker has been tested on edentulous elders using structural equation model (SEM) analysis. However, cross-sectional designs and the Short-Form Oral Health Impact Profile (OHIP-14) cannot adequately express cause-effect relationships and distribution in edentulous patients. Accordingly, the authors investigated Locker's model using an interventional design that included complete denture replacement using the OHIP for edentulous subjects (OHIP-EDENT). A total of 265 edentulous participants who visited the Dental Hospital of Tokyo Medical and Dental University (Tokyo, Japan) for new complete dentures were recruited. Locker's model was investigated, and CFA was performed using the change in subscale scores in the Japanese version of the OHIP-EDENT before and after complete denture replacement. CFA demonstrated an excellent model fit after adding several covariates. The Locker model also met the criteria of fit in all indices after 1 nonsignificant path was omitted. All path coefficients were significant. The findings of the present interventional study demonstrated an empirical fit to Locker's model in edentulous elders using SEM analysis, which included complete denture replacement. It is anticipated that clarification of causal mechanisms of oral health-related quality of life will lead to improvement of overall quality of life, thus maintaining or improving the activities of normal daily life for edentulous elders. © 2018 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  8. Selecting maxillary anterior tooth width by measuring certain facial dimensions in the Kurdish population.

    PubMed

    A L-Kaisy, Neda; Garib, Balkees Taha

    2016-03-01

    One of the most difficult aspects of complete denture fabrication is selecting appropriately sized maxillary anterior teeth that will harmonize with the face. There are no generally accepted or naturally observed principles to guide dentists in this selection. The purpose of this study was to determine whether a relationship exists between various facial measurements and the different single or combined mesiodistal widths of maxillary anterior teeth in a Kurdish population. A total of 65 Kurdish dental students participated in this study. Two standardized digital photographs of the face (relaxed and smiling capture) were recorded. The interpupillary distance (IPD), inner canthal distance (ICD), interalar distance (IAD), and width of the 2 central incisors were determined by Image J software. The mesiodistal width and the combined straight-line width of the centrals, laterals, and canines were measured directly from the casts of the participants with digital calipers. A simple linear regression and the Pearson correlation coefficient were used to investigate the relationship between the particular facial measurement and the widths of the anterior teeth (α=.05). Significant correlations existed between the IPD and different tooth measurements; the highest was with the mean width of the canines (r=0.55). The proposed proportion between the IPD and the central incisor width was 6.93. The golden proportion of the ICD to the width of the central incisors and of the IAD to the straight-line width of the 6 anterior teeth could be used as a dependent parameter in Kurdish men. The IPD can be used to predict the width of anterior teeth in both sexes. In men, the width of the central incisors may be estimated from the ICD and the straight-line width of the 6 anterior teeth from the IAD. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  9. Live broadcast lectures on complete denture prosthodontics at Tokyo Medical and Dental University: comparison of two years.

    PubMed

    Iwaki, Maiko; Kanazawa, Manabu; Sunaga, Masayo; Kinoshita, Atsuhiro; Minakuchi, Shunsuke

    2013-03-01

    A live broadcasting system was developed as part of dental education with Information and Communication Technology (ICT) at Tokyo Medical and Dental University. The purpose of this study was to utilize this system in complete denture prosthodontics, especially for the procedure of making a definitive impression with custom tray border molding in edentulous patients, and to evaluate its effectiveness. Live broadcast lectures on complete denture prosthodontics were given to fourth-year students in 2009 (fifty-nine students) and in 2010 (sixty-five students). To evaluate this lecture, a questionnaire was distributed to the students and faculty members after the lecture. Almost all the students and faculty members rated the lecture as good. Students commented that the lecture was "intelligible," "inspiring," "improved understanding," "good because they could ask questions in real time," "helped to know the actual time," "good for all the students to see the same case," and "close to real experience and induced a sense of tension." The results of this study suggested that a live broadcast lecture would help students experience the real clinical situation and aid in teaching complete denture prosthodontics.

  10. Finite element analysis of provisional structures of implant-supported complete prostheses.

    PubMed

    Carneiro, Bruno Albuquerque; de Brito, Rui Barbosa; França, Fabiana Mantovani Gomes

    2014-04-01

    The use of provisional resin implant-supported complete dentures is a fast and safe procedure to restore mastication and esthetics of patients soon after surgery and during the adaptation phase to the new denture. This study assessed stress distribution of provisional implant-supported fixed dentures and the all-on-4 concept using self-curing acrylic resin (Tempron) and bis-acrylic resin (Luxatemp) to simulate functional loads through the three-dimensional finite element method. Solidworks software was used to build three-dimensional models using acrylic resin (Tempron, model A) and bis-acrylic resin (Luxatemp, model B) for denture captions. Two loading patterns were applied on each model: (1) right unilateral axial loading of 150 N on the occlusal surfaces of posterior teeth and (2) oblique loading vector of 150 N at 45°. The results showed that higher stress was found on the bone crest below oblique load application with a maximum value of 187.57 MPa on model A and 167.45 MPa on model B. It was concluded that model B improved stress distribution on the denture compared with model A.

  11. The effect of various factors on the masticatory performance of removable denture wearer

    NASA Astrophysics Data System (ADS)

    Pratama, S.; Koesmaningati, H.; Kusdhany, L. S.

    2017-08-01

    An individual’s masticatory performance concerns his/her ability to break down food in order to facilitate digestion, and it therefore plays an important role in nutrition. Removable dentures are used to rehabilitate a loss of teeth, which could jeopardize masticatory performance. Further, there exist various other factors that can affect masticatory performance. The objective of this research is to analyze the relationship between various factors and masticatory performance. Thirty-four removable denture wearers (full dentures, single complete dentures, or partial dentures) participated in a cross-sectional study of masticatory performance using color-changeable chewing gum (Masticatory Performance Evaluating Gum Xylitol®). The volume of saliva was evaluated using measuring cups, while the residual ridge heights were measured using a modified mouth mirror no. 3 with metric measurements. The residual ridge height and removable-denture-wearing experience exhibited a significant relationship with masticatory performance. However, age, gender, saliva volume, denture type, and the number and location of the missing teeth did not have a statistically significant association with masticatory performance. The residual ridge height influences the masticatory performance of removable denture wearers, since the greater the ridge height, the better the performance. The experience of using dentures also has a statistically significant influence on masticatory performance.

  12. Knowledge of removable partial denture wearers on denture hygiene.

    PubMed

    Milward, P; Katechia, D; Morgan, M Z

    2013-11-01

    Regular good denture hygiene by individuals with removable partial dentures (RPDs) is an important component of oral health and in the prevention of further dental problems. These individuals should be provided with advice on the importance of denture care and be aware of this information. To establish deficiencies in patient knowledge surrounding denture hygiene by RPD wearers. The study was undertaken as an audit. Data was collected from April 2012 to October 2012 via a questionnaire completed by 196 RPD wearers attending as patients at the University Dental Hospital Wales and the dental units at St David's Hospital and Cynon Valley Hospital. The audit criterion was patients with RPDs should have knowledge of denture hygiene, with the standard set at 100%. While 91.8% of participants stated they were provided with instructions on denture hygiene when provided with their current prosthesis, 60.2% were shown to have less than an appropriate level of denture cleanliness, with 9.2% reporting that they slept wearing their prosthesis. The audit criterion and standard set were not achieved. A lack of knowledge surrounding denture hygiene was demonstrated among participants. As a part of the audit process the health education of RPD wearers' hygiene needs to be improved and awareness levels of the whole dental team needs to be raised. All partial dentures should receive information and regular reinforcement of key dental hygiene messages.

  13. BIOMECHANICAL ANALYSIS OF THE STRESSES GENERATED BY DIFFERENT DISOCCLUSION PATTERNS IN AN IMPLANT-SUPPORTED MANDIBULAR COMPLETE DENTURE

    PubMed Central

    Greco, Gustavo Diniz; Jansen, Wellington Corrêa; Landre, Janis; Seraidarian, Paulo Isaías

    2009-01-01

    Objectives: This study evaluated by three-dimensional finite element analysis the tensions generated by different disocclusion patterns (canine guide and bilateral balanced occlusion) in an implant-supported mandibular complete denture. Material and Methods: A three-dimensional model of implant-supported mandibular complete denture was fabricated according to the Brånemark protocol. A 5-element 3.75 x 13-mm screw-shape dental implant system was modeled for this study. The implants were located in the intermental foramen region with 3-mm-high prosthetic components joined by a nickel-chromium framework with 12-mm bilateral cantilever covered by acrylic resin and 12 acrylic denture teeth. SolidWorks® software was used before and after processing the simulations. The mechanical properties of the components were inserted in the model and a 15 N load was established in fixed points, in each one of the simulations. Data were collected in the entire nickel-chromium framework. The results were displayed three-dimensionally as color graphic scales. Results: The canine guide generated greater tensions in the region of the first implant, while the bilateral balanced occlusion generated great tensions in the entire metallic framework. The maximum tension found in the simulation of the bilateral balanced occlusion was 3.22 fold higher than the one found in the simulation of the disocclusion in canine guide. Conclusion: The pattern of disocclusion in canine guide is the ideal for implant-supported mandibular complete denture. PMID:19936535

  14. Biomechanical analysis of the stresses generated by different disocclusion patterns in an implant-supported mandibular complete denture.

    PubMed

    Greco, Gustavo Diniz; Jansen, Wellington Corrêa; Landre Junior, Janis; Seraidarian, Paulo Isaías

    2009-01-01

    This study evaluated by three-dimensional finite element analysis the tensions generated by different disocclusion patterns (canine guide and bilateral balanced occlusion) in an implant-supported mandibular complete denture. A three-dimensional model of implant-supported mandibular complete denture was fabricated according to the Brånemark protocol. A 5-element 3.75 x 13-mm screw-shape dental implant system was modeled for this study. The implants were located in the inter-mental foramen region with 3-mm-high prosthetic components joined by a nickel-chromium framework with 12-mm bilateral cantilever covered by acrylic resin and 12 acrylic denture teeth. SolidWorks software was used before and after processing the simulations. The mechanical properties of the components were inserted in the model and a 15 N load was established in fixed points, in each one of the simulations. Data were collected in the entire nickel-chromium framework. The results were displayed three-dimensionally as color graphic scales. The canine guide generated greater tensions in the region of the first implant, while the bilateral balanced occlusion generated great tensions in the entire metallic framework. The maximum tension found in the simulation of the bilateral balanced occlusion was 3.22 fold higher than the one found in the simulation of the disocclusion in canine guide. The pattern of disocclusion in canine guide is the ideal for implant-supported mandibular complete denture.

  15. Forensic odontology: A prosthodontic view

    PubMed Central

    Gosavi, Sulekha; Gosavi, Siddharth

    2012-01-01

    The most common role of the forensic dentist is the identification of deceased individuals. Dental identifications have always played a key role in natural and manmade disaster situations, and in particular, the mass casualties normally associated with aviation disasters. Because of the lack of a comprehensive fingerprint database, dental identification continues to be crucial in the world. An all-acrylic resin appliance such as a full denture or an all-acrylic partial denture (or orthodontic appliance), prior to delivery, could be inscribed with the patient's full name on a substrate (paper, metal) and sealed inconspicuously into the surface of a denture by various processes. It has been noted by several authors that in many cases of air disaster where the limbs are completely burnt off, some denture materials survive, especially the posterior part of acrylic dentures and metal-based dentures. Thus, marked dental prostheses (full and partial dentures, mouthguards and removal orthodontic appliances) would lead to rapid identification in the event of accidents and disaster. PMID:23087581

  16. Implant Mandibular Overdentures Retained by Immediately Loaded Implants: A 1-Year Randomized Trial Comparing the Clinical and Radiographic Outcomes Between Mini Dental Implants and Standard-Sized Implants.

    PubMed

    Zygogiannis, Kostas; Aartman, Irene Ha; Parsa, Azin; Tahmaseb, Ali; Wismeijer, Daniel

    The aim of this 1-year randomized trial was to evaluate and compare the clinical and radiographic performance of four immediately loaded mini dental implants (MDIs) and two immediately loaded standard-sized tissue-level (STL) implants, placed in the interforaminal region of the mandible and used to retain mandibular overdentures (IODs) in completely edentulous patients. A total of 50 completely edentulous patients wearing conventional maxillary dentures and complaining about insufficient retention of their mandibular dentures were divided into two groups; 25 patients received four MDIs and 25 patients received two STL implants. The marginal bone loss (MBL) at the mesial and distal sides of each implant was assessed by means of standardized intraoral radiographs after a period of 1 year. Implant success and survival rates were also calculated. Immediate loading was possible for all patients in the first group. In the second group, an immediate loading protocol could not be applied for 10 patients. These patients were treated with a delayed loading protocol. A mean MBL of 0.42 ± 0.56 mm for the MDIs and 0.54 ± 0.49 mm for the immediately loaded STL implants was recorded at the end of the evaluation period. There was no statistically significant difference between the MDIs and the immediately loaded STL implants. Two MDIs failed, resulting in a survival rate of 98%. The success rate was 91%. For the immediately loaded conventional implants, the survival rate was 100% and the success rate 96.7% after 1 year of function. However, in 10 patients, the immediate loading protocol could not be followed. Considering the limitations of this short-term clinical study, immediate loading of four unsplinted MDIs or two splinted STL implants to retain mandibular overdentures seems to be a feasible treatment option. The marginal bone level changes around the MDIs were well within the clinically acceptable range.

  17. Diagnosis and treatment of orofacial pain in a patient with unserviceable complete dentures: A clinical report.

    PubMed

    Selecman, Audrey M; Ahuja, Swati A

    2018-02-08

    An ill-fitting complete denture has the potential to create pain and discomfort as well as conceal or confound the diagnosis of other primary sources of orofacial pain such as trigeminal neuralgia. Guidelines of the American Academy of Orofacial Pain offer an evidence-based approach for the assessment, diagnosis, and management of orofacial pain. A complete and accurate differential diagnosis is paramount to the success of treatment as well as to the circumvention of unnecessary therapy. The purpose of this clinical report was to emphasize an evidence-based approach to the diagnosis and treatment of orofacial pain in a patient with edentulism and a history of prolonged denture wear. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  18. Retention of denture bases fabricated by three different processing techniques – An in vivo study

    PubMed Central

    Chalapathi Kumar, V. H.; Surapaneni, Hemchand; Ravikiran, V.; Chandra, B. Sarat; Balusu, Srilatha; Reddy, V. Naveen

    2016-01-01

    Aim: Distortion due to Polymerization shrinkage compromises the retention. To evaluate the amount of retention of denture bases fabricated by conventional, anchorized, and injection molding polymerization techniques. Materials and Methods: Ten completely edentulous patients were selected, impressions were made, and master cast obtained was duplicated to fabricate denture bases by three polymerization techniques. Loop was attached to the finished denture bases to estimate the force required to dislodge them by retention apparatus. Readings were subjected to nonparametric Friedman two-way analysis of variance followed by Bonferroni correction methods and Wilcoxon matched-pairs signed-ranks test. Results: Denture bases fabricated by injection molding (3740 g), anchorized techniques (2913 g) recorded greater retention values than conventional technique (2468 g). Significant difference was seen between these techniques. Conclusions: Denture bases obtained by injection molding polymerization technique exhibited maximum retention, followed by anchorized technique, and least retention was seen in conventional molding technique. PMID:27382542

  19. Ectodermal Dysplasia: A Case Report

    PubMed Central

    2011-01-01

    Ectodermal dysplasia is a hereditary disease characterized by dysplasia of tissues of ectodermal origin. The incidence of ectodermal dysplasia is rare (1 in 100,000 birth). This case report discusses the features, classification and prosthetic treatment plan (upper partial denture and lower complete denture for upper partial and lower complete edentulous arches respectively). This treatment plan would be able to provide psychological and functional boost to the sufferer. PMID:27678241

  20. Effects of mouth rehabilitation with removable complete dentures on stimulus perception and the electromyographic activity of the orbicularis oris muscle.

    PubMed

    de Caxias, Fernanda P; Dos Santos, Daniela M; Goiato, Marcelo C; Bitencourt, Sandro B; da Silva, Emily V F; Laurindo-Junior, Murilo C B; Turcio, Karina H L

    2018-05-01

    Many elderly individuals are rehabilitated with removable complete dentures, which require an initial adaptation period for both oral perception and the perioral muscles. Studies assessing the changes in stimulus perception and the electromyographic (EMG) activity of the orbicularis oris muscle shortly after conventional complete denture insertion are lacking. The purpose of this clinical study was to evaluate the effect of mouth rehabilitation with removable complete dentures on stimulus perception and the EMG activity of the orbicularis oris muscle. This study was approved by the Human Research Ethics Committee of the Araçatuba Dental School (São Paulo State University). Fifteen participants who had worn their removable complete dentures for at least 5 years and needed rehabilitation with new prostheses were enrolled in the study. A perception questionnaire was applied, and surface EMG examinations of the orbicularis oris muscle during rest, suction of water with a straw, and pronunciation of the syllables /bah/, /mah/, /pah/, and the word 'Mississippi' were performed before (T0) and 30 (T1) and 100 (T2) days after insertion of the new prostheses. The data were analyzed with the Cochran Q test, McNemar test, 2-way repeated measures ANOVA, and honestly significant difference (HSD) Tukey test (α=.05). Significant improvement was reported in the perception questionnaire in terms of the oral discomfort sensation in the T2 period. EMG activity decreased during rest and suction after insertion of the new prostheses. A statistical difference between the upper and lower fascicles of the orbicularis oris muscle was detected, with a decrease of EMG activity between the T0 and T1 periods on the lower fascicle, except for when pronouncing the /pah/ syllable. Mouth rehabilitation with removable complete dentures decreased oral discomfort and, depending on the oral function, decreased or increased EMG activity of the orbicularis oris muscle. In addition, the lower fascicle was more active than the upper fascicle during rest and most functional activities. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. Influence of denture adhesives on occlusion and disocclusion times.

    PubMed

    Abdelnabi, Mohamed Hussein; Swelem, Amal Ali; Al-Dharrab, Ayman A

    2016-03-01

    The effectiveness of adhesives in enhancing several functional aspects of complete denture performance has been well established. The direct influence of adhesives on occlusal contact simultaneity has not yet been investigated. The purpose of this crossover clinical trial was to evaluate quantitatively the influence of adhesives on occlusal balance by recording timed occlusal contacts; namely occlusion time (OT) and disocclusion time during right (DT-right) and left (DT-left) excursions by using computerized occlusal analysis. A crossover clinical trial was adopted. Assessments were carried out while participants (n=49) wore their dentures first without then with adhesives. Computerized occlusal analysis using the T-Scan III system was conducted to perform baseline computer-guided occlusal adjustment for conventionally fabricated dentures. Retention and stability assessment using the modified Kapur index and recording of OT and DT-right and DT-left values using the T-Scan III were subsequently carried out for all dentures, first without adhesives and then after application of adhesive. All T-Scan procedures were carried out by the same clinician. Wilcoxon signed-rank test was used to analyze the Kapur index scores and occlusal parameters (α=.05). Stability and retention of conventional dentures ranged initially from good to very good. However, adhesive application resulted in significant improvement (P<.001) in stability and retention and a significant decrease in duration of all occlusal parameters (OT [P=.003], DT-right [P=.003], and DT-left [P=.008]). Adhesives significantly decreased OT and DT durations in initially well-fitting complete dentures with fairly well balanced occlusion, and further enhanced denture stability and occlusal contact simultaneity. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. The decade of overdentures: 1970-1980.

    PubMed

    Fenton, A H

    1998-01-01

    Jaw bones resorb when teeth are lost. People cannot function as well with complete dentures compared with their natural teeth. As more people are living longer and these cumulative effects become increasingly documented, dentists in the 1970s attached more importance to keeping teeth. The concept of overdentures developed as a simple and economic alternative to prolong the retention and function of the last few teeth in a compromised dentition. The previous option was extensive fixed prosthodontics. An overdenture is a complete or removable partial denture that has one or more tooth roots to provide support. Rather than extracting all compromised teeth, the crowns, and pulpal tissue of selected teeth (usually two anterior teeth) are removed. The remaining root projecting through the mucosa is restored and/or contoured. With the crown removed, there is space to cover the area with a denture. The root has less mobility, and its retention retards bone resorption. Overdentures with roots are more stable, and patients can chew better than with dentures supported on residual alveolar bone and mucosal tissue alone. Keeping even a few teeth has a strong psychological value for some patients. Patients who have lost teeth, adjacent tissue, and bone need replacement of more oral structures than tooth crowns alone can provide. A complete denture with flange contours can restore tissue and appearance. The conventional tooth-supported overdenture concept continues to be an accepted treatment modality and has now been adapted to implants.

  3. In Vitro Wear Resistance of Nano-Hybrid Composite Denture Teeth.

    PubMed

    Munshi, Nabeel; Rosenblum, Marc; Jiang, Shuying; Flinton, Robert

    2017-04-01

    To evaluate the wear resistance of nano-hybrid composite denture teeth as compared to two commonly used denture teeth: interpenetrating polymer network (IPN) and double crosslinking polymethylmethacrylate (PMMA) denture teeth. 18 styli and 18 disk specimens were prepared from the three denture tooth materials: nano-hybrid composite, IPN, and double crosslinking PMMA. The specimens were mounted in a two-body wear testing machine to simulate chewing in the complete denture. The amount of wear from the styli specimens were measured before and after using a digital micrometer, and the depth of the wear track from the disk specimens was measured using a noncontact 3D optical profilometer. The total wear from each denture tooth group was compared using one-way ANOVA with a 0.05 significance level. A Tukey post hoc test was used to determine differences between the three groups. The mean total wear in the nano-hybrid composite teeth group was 1.16 mm, SD = 0.5 mm, statistically significantly higher (p ≤ 0.0001) than the IPN (mean = 0.13 mm, SD = 0.05) and double crosslinking PMMA tooth groups (mean = 0.31 mm, SD = 0.19). There was no statistically significant difference between IPN denture teeth and double crosslinking PMMA denture teeth in the amount of wear. Nano-hybrid composite denture teeth exhibited statistically significantly more wear than the IPN and double crosslinking PMMA denture teeth. © 2015 by the American College of Prosthodontists.

  4. A simplified chair-side remount technique using customized mounting platforms.

    PubMed

    Chauhan, Mamta Devendrakumar; Dange, Shankar Pandharinath; Khalikar, Arun Narayan; Vaidya, Smita Padmakar

    2012-08-01

    Correct occlusal relationships are part of the successful prosthetic treatment for edentulous patients. Fabrication of complete dentures comprises of clinical and laboratory procedures that should be executed accurately for achieving success with fabricated dentures. Errors occurring during the clinical and laboratory procedures of a denture may subsequently lead to the occlusal errors in the final prosthesis. These occlusal errors can be corrected in two ways: i) in patient's mouth ii) by recording new centric relation and remounting dentures on an articulator. The latter method is more feasible because the mobility of denture base on the mucosa in oral cavity does not permit the identification of premature contacts in centric occlusion and tooth guided eccentric excursions. This article describes a modest and effective clinical chair-side remount procedure using customized mounting platforms.

  5. A simplified chair-side remount technique using customized mounting platforms

    PubMed Central

    Dange, Shankar Pandharinath; Khalikar, Arun Narayan; Vaidya, Smita Padmakar

    2012-01-01

    Correct occlusal relationships are part of the successful prosthetic treatment for edentulous patients. Fabrication of complete dentures comprises of clinical and laboratory procedures that should be executed accurately for achieving success with fabricated dentures. Errors occurring during the clinical and laboratory procedures of a denture may subsequently lead to the occlusal errors in the final prosthesis. These occlusal errors can be corrected in two ways: i) in patient's mouth ii) by recording new centric relation and remounting dentures on an articulator. The latter method is more feasible because the mobility of denture base on the mucosa in oral cavity does not permit the identification of premature contacts in centric occlusion and tooth guided eccentric excursions. This article describes a modest and effective clinical chair-side remount procedure using customized mounting platforms. PMID:22977726

  6. Development of a digital impression procedure using photogrammetry for complete denture fabrication.

    PubMed

    Matsuda, Takashi; Goto, Takaharu; Kurahashi, Kosuke; Kashiwabara, Toshiya; Ichikawa, Tetsuo

    We developed an innovative procedure for digitizing maxillary edentulous residual ridges with a photogrammetric system capable of estimating three-dimensional (3D) digital forms from multiple two-dimensional (2D) digital images. The aim of this study was to validate the effectiveness of the photogrammetric system. Impressions of the maxillary residual ridges of five edentulous patients were taken with four kinds of procedures: three conventional impression procedures and the photogrammetric system. Plaster models were fabricated from conventional impressions and digitized with a 3D scanner. Two 3D forms out of four forms were superimposed with 3D inspection software, and differences were evaluated using a least squares best fit algorithm. The in vitro experiment suggested that better imaging conditions were in the horizontal range of ± 15 degrees and at a vertical angle of 45 degrees. The mean difference between the photogrammetric image (Form A) and the image taken from conventional preliminarily impression (Form C) was 0.52 ± 0.22 mm. The mean difference between the image taken of final impression through a special tray (Form B) and Form C was 0.26 ± 0.06 mm. The mean difference between the image taken from conventional final impression (Form D) and Form C was 0.25 ± 0.07 mm. The difference between Forms A and C was significantly larger than the differences between Forms B and C and between Forms D and C. The results of this study suggest that obtaining digital impressions of edentulous residual ridges using a photogrammetric system is feasible and available for clinical use.

  7. [Systematic review and meta-analysis on the effect of implant supported overdentures on the oral health related quality of life of edentulous patients].

    PubMed

    Zhang, S S; Zhang, Y; Di, P; Lin, Y

    2017-05-09

    Objective: To evaluate the effect of implant related treatment on the oral health related quality of life (OHRQoL) of edentulous patients. Methods: The CNKI, Wanfang database and Medline, EMBASE, Cochrane Library databases that include randomized clinical trials comparing implant supported overdentures with conventional complete denture for edentulous patients were retrived. Nine studies involving 769 cases were included and meta-analysis was conducted. Results: The standardized mean difference (SMD) of oral health impact profile (OHIP) score was 1.63 (95% CI: 1.25-2.02) and improved after implant related treatment, which was significantly better than the conventional complete denture (0.87, 95% CI: 0.54-1.20). Conclusions: Implant supported overdentures improved patient's OHRQoL and showed better performance compared to the overdentures complete dentures.

  8. Oral health-related quality of life in patients with non-metal clasp dentures: a randomised cross-over trial.

    PubMed

    Fueki, K; Yoshida-Kohno, E; Wakabayashi, N

    2017-05-01

    We investigated the efficacy of non-metal clasp dentures (NMCDs) with regard to the oral health-related quality of life (OHRQoL) and compare the findings with those for conventional metal clasp-retained dentures (MCDs). This single-centre, randomised controlled, two-phase, open label, cross-over trial included 28 partially dentate individuals. The patients were randomised to receive MCDs followed by NMCDs, or the opposite sequence (n = 14 in each group); each denture was worn for 3 months. OHRQoL was evaluated using the Oral Health Impact Profile-Japanese version (OHIP-J) at entry (T-entry; before treatment with the first denture) and at 3 months after treatment with each denture (T3). An examiner evaluated denture stability, oral appearance and surface roughness before denture delivery (T0) and at T3 and denture hygiene at T3. A total of 24 patients completed the trial. There were no complications related to the dentures, abutment teeth or denture-bearing mucosa during the follow-up periods for both dentures. The mean OHIP summary score was lower for NMCDs than for MCDs, and the difference (9 points) was greater than the minimal important difference (6 points), indicating the difference was clinically relevant. The effect size was medium (0·70). Statistical analyses with linear mixed models found a significant effect of the denture type on the OHIP summary score and scores for the Oro-facial appearance, Oro-facial pain and Psychological impact domains (NMCD < MCD; P < 0·05). The results of our study suggest that NMCDs allow for better OHRQoL compared with MCDs. © 2017 John Wiley & Sons Ltd.

  9. On denture marking.

    PubMed

    Borrman, H I; DiZinno, J A; Wasén, J; René, N

    1999-06-01

    During the last decades in Sweden dentures have been permanently marked with a stainless steel metal band incorporated into the acrylic and containing the patient's birth date, a special number, and "S" for Sweden. The last recommendation issued by the National Board of Health and Welfare states that "the patients shall always be offered denture marking and be informed about the benefit thereof. Denture marking is not permitted if the patient refuses it". Requirements for denture markers have been that they should be biologically inert (when incorporated into the denture), not be expensive, be easy to inscribe, be possible to retrieve after an accident, and survive elevated temperatures for a reasonable time under normal circumstances. Although the frequency of edentulousness has decreased in recent years due to the improvement in oral health there remains a need to address the issue of marking of complete dentures, because there is a large variation in the oral status of populations in different countries. Given that only one marked denture can reveal the identity of a deceased person when all other methods fail to do so, makes it worthwhile. Furthermore, denture marking is important in long-term care facilities. We have investigated the issue of denture marking in Europe and in the United States. The results from the European survey show that denture marking is, to our knowledge regulated by law only in Sweden and Iceland. In the US denture marking is so far mandatory in 21 states while New York State requires dentures to be marked if the patient requests it and several other states impose the obligation to mark dentures on long-term care facilities. Since there is no international consensus regarding the issue of denture marking it is important to address it. A survey from the Nordic countries has shown that if denture marking was in general use, the contribution to the establishment of identity by forensic odontology in cases of fire would increase by about 10%. This means that about 25 more individuals could have been identified if their dentures were marked. Increased international collaboration is needed to solve the issue of denture marking for clinical and forensic purposes.

  10. Occlusion and Temporomandibular Function among Subjects with Mandibular Distal Extension Removable Partial Dentures

    PubMed Central

    Creugers, N. H. J.; Witter, D. J.; Van 't Spijker, A.; Gerritsen, A. E.; Kreulen, C. M.

    2010-01-01

    Objective. To quantify effects on occlusion and temporomandibular function of mandibular distal extension removable partial dentures in shortened dental arches. Methods. Subjects wearing mandibular extension removable partial dentures (n = 25) were compared with subjects with shortened dental arches without extension (n = 74) and with subjects who had worn a mandibular extension removable partial denture in the past (n = 19). Subjects with complete dentitions (n = 72) were controls. Data were collected at baseline and at 3-, 6-, and 9-year observations. Results. Occlusal activity in terms of reported awareness of bruxism and occlusal tooth wear of lower anterior teeth did not differ significantly between the groups. In contrast, occlusal tooth wear of premolars in shortened dental arches with or without extension dentures was significantly higher than in the controls. Differences amongst groups with respect to signs and symptoms related to temporomandibular disorders were not found. Occlusal support of the dentures did not influence anterior spatial relationship. Occlusal contacts of the denture teeth decreased from 70% for second premolars via 50% for first molars, to 30% for second molars. Conclusions. Mandibular distal extension removable partial dentures in moderate shortened dental arches had no effects on occlusion and temporomandibular function. PMID:20671961

  11. The management of an endodontically abscessed tooth: patient health state utility, decision-tree and economic analysis

    PubMed Central

    Balevi, Ben; Shepperd, Sasha

    2007-01-01

    Background A frequent encounter in clinical practice is the middle-aged adult patient complaining of a toothache caused by the spread of a carious infection into the tooth's endodontic complex. Decisions about the range of treatment options (conventional crown with a post and core technique (CC), a single tooth implant (STI), a conventional dental bridge (CDB), and a partial removable denture (RPD)) have to balance the prognosis, utility and cost. Little is know about the utility patients attach to the different treatment options for an endontically abscessed mandibular molar and maxillary incisor. We measured patients' dental-health-state utilities and ranking preferences of the treatment options for these dental problems. Methods Forty school teachers ranked their preferences for conventional crown with a post and core technique, a single tooth implant, a conventional dental bridge, and a partial removable denture using a standard gamble and willingness to pay. Data previously reported on treatment prognosis and direct "out-of-pocket" costs were used in a decision-tree and economic analysis Results The Standard Gamble utilities for the restoration of a mandibular 1st molar with either the conventional crown (CC), single-tooth-implant (STI), conventional dental bridge (CDB) or removable-partial-denture (RPD) were 74.47 [± 6.91], 78.60 [± 5.19], 76.22 [± 5.78], 64.80 [± 8.1] respectively (p < 0.05). Their respective Willingness-to-Pay ($CDN) were 1,782.05 [± 361.42], 1,871.79 [± 349.44], 1,605.13 [± 348.10], 1,351.28 [± 368.62] (p < 0.05). The standard gamble utilities for the restoration of a maxillary central incisor with a CC, STI, CDB and RPD were 88.50 [± 6.12], 90.68 [± 3.41], 89.78 [± 3.81] and 91.10 [± 3.57] respectively (p > 0.05). Their respective willingness-to-pay ($CDN) were: 1,782.05 [± 361.42], 1,871.79 [± 349.44], 1,605.13 [± 348.10] and 1,351.28 [± 368.62]. A statistical difference was found between the utility of treating a maxillary central incisor and mandibular 1st-molar (p < 0.05). The expected-utility-value for a 5-year prosthetic survival was highest for the CDB and the STI treatment of an abscessed mandibular molar (74.75 and 71.47 respectively) and maxillary incisor (86.24 and 84.91 respectively). This held up to a sensitivity analysis when the success of root canal therapy and the risk of damage to the adjacent tooth were varied. The RPD for both the molar and incisor was the favored treatment based on a cost-utility (3.85 and 2.74 CND$ per year of tooth saved respectively) and cost-benefit analysis (0.92 to 0.60 CND$ of cost per $ of benefit, respectively) for a prosthetic clinical survival of 5-years. Conclusion The position of the abscessed tooth and the amount of insurance coverage influences the utility and rank assigned by patients to the different treatment options. STI and CDB have optimal EUVs for a 5-year survival outcome, and RPD has significantly lower cost providing the better cost:benefit ratio. PMID:18053267

  12. Nutritional status assessment in complete denture wearers.

    PubMed

    Prakash, Nagaranjani; Kalavathy, Natarajan; Sridevi, Janakiramareddy; Premnath, Kumareshan

    2012-09-01

    The relationship between oral health and the nutritional status in the elderly is complex and controversial. It has been suggested that poor oral health and a decreased ability to chew have a profound influence on food selection, diet and thereby the nutritional status of the individual. This study aimed to evaluate the effect of edentulousness and prosthetic treatment on the nutritional status of the individual. A total of 94 patients were selected for the study, which was conducted over a period of 16 months. The nutritional status was assessed using the Mini Nutritional Assessment Form (MNA) before the complete denture treatment and after an interval of 6 months and 9 months following the treatment. The individual scores obtained for each question and the total scores at the baseline study were compared with those obtained after 6 and 9 months. Proportions were compared using chi-squared test of significance. The results showed statistically significant differences in the total MNA scores between the baseline study and after 6 and 9 months. The edentulous patients without complete dentures had significantly lower MNA scores. Prosthetic rehabilitation of the edentulous patients with complete dentures, along with the dietary counselling, improved the nutritional status of these patients. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

  13. Deep pain sensitivity is correlated with oral-health-related quality of life but not with prosthetic factors in complete denture wearers

    PubMed Central

    COSTA, Yuri Martins; PORPORATTI, André Luís; HILGENBERG-SYDNEY, Priscila Brenner; BONJARDIM, Leonardo Rigoldi; CONTI, Paulo César Rodrigues

    2015-01-01

    ABSTRACT Low pressure Pain Threshold (PPT) is considered a risk factor for Temporomandibular Disorders (TMD) and is influenced by psychological variables. Objectives To correlate deep pain sensitivity of masticatory muscles with prosthetic factors and Oral-Health-Related Quality of Life (OHRQoL) in completely edentulous subjects. Material and Methods A total of 29 complete denture wearers were recruited. The variables were: a) Pressure Pain Threshold (PPT) of the masseter and temporalis; b) retention, stability, and tooth wear of dentures; c) Vertical Dimension of Occlusion (VDO); d) Oral Health Impact Profile (OHIP) adapted to orofacial pain. The Kolmogorov-Smirnov test, the Pearson Product-Moment correlation coefficient, the Spearman Rank correlation coefficient, the Point-Biserial correlation coefficient, and the Bonferroni correction (α=1%) were applied to the data. Results The mean age (standard deviation) of the participants was of 70.1 years (9.5) and 82% of them were females. There were no significant correlations with prosthetic factors, but significant negative correlations were found between the OHIP and the PPT of the anterior temporalis (r=-0.50, 95% CI-0.73 to 0.17, p=0.005). Discussion The deep pain sensitivity of masticatory muscles in complete dentures wearers is associated with OHRQoL, but not with prosthetic factors. PMID:26814457

  14. Implant-supported overdenture with prefabricated bar attachment system in mandibular edentulous patient

    PubMed Central

    Ha, Seung-Ryong; Song, Seung-Il; Hong, Seong-Tae; Kim, Gy-Young

    2012-01-01

    Implant-supported overdenture is a reliable treatment option for the patients with edentulous mandible when they have difficulty in using complete dentures. Several options have been used for implant-supported overdenture attachments. Among these, bar attachment system has greater retention and better maintainability than others. SFI-Bar® is prefabricated and can be adjustable at chairside. Therefore, laboratory procedures such as soldering and welding are unnecessary, which leads to fewer errors and lower costs. A 67-year-old female patient presented, complaining of mobility of lower anterior teeth with old denture. She had been wearing complete denture in the maxilla and removable partial denture in the mandible with severe bone loss. After extracting the teeth, two implants were placed in front of mental foramen, and SFI-Bar® was connected. A tube bar was seated to two adapters through large ball joints and fixation screws, connecting each implant. The length of the tube bar was adjusted according to inter-implant distance. Then, a female part was attached to the bar beneath the new denture. This clinical report describes two-implant-supported overdenture using the SFI-Bar® system in a mandibular edentulous patient. PMID:23236580

  15. Two Body Wear of Newly Introduced Nanocomposite Teeth and Cross Linked Four Layered Acrylic Teeth: a Comparitive In Vitro Study.

    PubMed

    Ilangkumaran, R; Srinivasan, J; Baburajan, K; Balaji, N

    2014-12-01

    Wear of complete denture teeth results in compromise in denture esthetics and functions. To counteract this problem, artificial teeth with increased wear resistance had been introduced in the market such as nanocomposite teeth. The purpose of this study was to compare the amount of wear between nanocomposite teeth and acrylic teeth. Fifteen specimens were chosen from each group namely the nanocomposite teeth (SR_-PHONARES) and the acrylic teeth (ACRY PLUS). Maxillary premolar was only chosen for testing and the samples were customized according to the specifications of the pin on disc machine. Pin on disc machine is a two body tribometer which quantifies the amount of wear under a specific load and time. Test samples were mounted on to the receptacle of the pin on disc machine and tested under a load of 0.3 kg for 1,000 cycles of rotation against a 600 grit emery paper. The amount of wear is displayed from the digital reading obtained from the pin on disc machine. After statistical analysis, it was found that, the amount of wear is more in four layered acrylic teeth. The p value obtained is 0.002 (<0.005) thus implies that the difference in wear between nanocomposite teeth and acrylic teeth is statistically significant. Though the nanocomposite teeth has less amount of wear than the four layered acrylic teeth, the difference is very less and adds only to a little clinical significance but the cost of the nanocomposite is four times that of the acrylic teeth. Further clinical studies must be performed to confirm our results.

  16. A comparative finite elemental analysis of glass abutment supported and unsupported cantilever fixed partial denture.

    PubMed

    Ramakrishaniah, Ravikumar; Al Kheraif, Abdulaziz A; Elsharawy, Mohamed A; Alsaleh, Ayman K; Ismail Mohamed, Karem M; Rehman, Ihtesham Ur

    2015-05-01

    The purpose of this study was to investigate and compare the load distribution and displacement of cantilever prostheses with and without glass abutment by three dimensional finite element analysis. Micro-computed tomography was used to study the relationship between the glass abutment and the ridge. The external surface of the maxilla was scanned, and a simplified finite element model was constructed. The ZX-27 glass abutment and the maxillary first and second premolars were created and modified. The solid model of the three-unit cantilever fixed partial denture was scanned, and the fitting surface was modified with reference to the created abutments using the 3D CAD system. The finite element analysis was completed in ANSYS. The fit and total gap volume between the glass abutment and dental model were determined by Skyscan 1173 high-energy spiral micro-CT scan. The results of the finite element analysis in this study showed that the cantilever prosthesis supported by the glass abutment demonstrated significantly less stress on the terminal abutment and overall deformation of the prosthesis under vertical and oblique load. Micro-computed tomography determined a gap volume of 6.74162 mm(3). By contacting the mucosa, glass abutments transfer some amount of masticatory load to the residual alveolar ridge, thereby preventing damage to the periodontal microstructures of the terminal abutment. The passive contact of the glass abutment with the mucosa not only preserves the health of the mucosa covering the ridge but also permits easy cleaning. It is possible to increase the success rate of cantilever FPDs by supporting the cantilevered pontic with glass abutments. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  17. Comparison of two cleansing pastes for the removal of biofilm from dentures and palatal lesions in patients with atrophic chronic candidiasis.

    PubMed

    Andrucioli, Marcela Cristina Damião; de Macedo, Leandro Dorigan; Panzeri, Heitor; Lara, Elza Helena Guimarães; Paranhos, Helena de Freitas Oliveira

    2004-01-01

    The efficacy of 2 oral hygiene products, an experimental toothpaste specific for complete denture cleansing and a regular standard toothpaste, was compared in terms of denture biofilm removal and cure of palatal lesions in patients with atrophic chronic candidiasis. The degree of correlation between presence of biofilm and mucosa erythema was also evaluated. Twenty-four complete denture wearers (45-80 years old) were divided into 2 groups: experimental paste and standard toothpaste (Sorriso-Kolynos, Brazil). Both groups received soft toothbrushes. The internal surfaces of upper dentures were stained using 1% sodium fluorescein and photographed at a 45 masculine angle at 0, 15, 30 and 60 days. The slides were scanned and the areas of interest (denture total area and biofilm area) were measured (Image Tool software). The degree of erythema was evaluated on slides according to the Prosthesis Tissue Index. There was a significant reduction (1%) in the degree of biofilm (ANOVA/Tukey) between the two initial visits (0 and 15 days) and the two final visits (30 and 60 days), and in the average erythema scores (Kruskal-Wallis) between 0 and 60 days, in both groups. The Mann-Whitney test showed a significant difference (1%) between pastes in terms of biofilm degree, but no difference was found for the erythema score. Correlation values between biofilm and erythema degree were 0.3801 (experimental paste) and (0.3678 (standard toothpaste). We may therefore conclude that the experimental product was efficient for the removal of denture plaque biofilm.

  18. Implant-supported and magnet-retained oral-nasal combination prosthesis in a patient with a total rhinectomy and partial maxillectomy due to cancer: A clinical report.

    PubMed

    Won, Alexander M; Montgomery, Patti; Aponte-Wesson, Ruth; Chambers, Mark

    2017-02-01

    This clinical report describes the fabrication of an implant-supported and magnet-retained combination oral-nasal prosthesis for a patient with a midline midfacial defect. The patient had undergone a total rhinectomy and partial maxillectomy as part of his cancer treatment. The nasal prosthesis was retained on the face by a magnet attached to the implant-supported maxillary denture, resulting in improved appearance and the recovery of speech, mastication, and swallowing functions. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  19. Management of long span partially edentulous maxilla with fixed removable denture prosthesis

    PubMed Central

    Jeyavalan, Mahilan I.; Narasimman, M.; Venkatakrishnan, C. J.; Philip, Jacob M.

    2012-01-01

    Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis. PMID:23293488

  20. Management of long span partially edentulous maxilla with fixed removable denture prosthesis.

    PubMed

    Jeyavalan, Mahilan I; Narasimman, M; Venkatakrishnan, C J; Philip, Jacob M

    2012-07-01

    Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis.

  1. Final-impression techniques and materials for making complete and removable partial dentures.

    PubMed

    Jayaraman, Srinivasan; Singh, Balendra P; Ramanathan, Balasubramanian; Pazhaniappan Pillai, Murukan; MacDonald, Laura; Kirubakaran, Richard

    2018-04-04

    Edentulism is relatively common and is often treated with the provision of complete or partial removable dentures. Clinicians make final impressions of complete dentures (CD) and removable partial dentures (RPD) using different techniques and materials. Applying the correct impression technique and material, based on an individual's oral condition, improves the quality of the prosthesis, which may improve quality of life. To assess the effects of different final-impression techniques and materials used to make complete dentures, for retention, stability, comfort, and quality of life in completely edentulous people.To assess the effects of different final-impression techniques and materials used to make removable partial dentures, for stability, comfort, overextension, and quality of life in partially edentulous people. Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 22 November 2017), the Cochrane Central Register of Controlled Trials (CENTRAL) (Cochrane Register of Studies, to 22 November 2017), MEDLINE Ovid (1946 to 22 November 2017), and Embase Ovid (21 December 2015 to 22 November 2017). The US National Institutes of Health Trials Registry (ClinicalTrials.gov) and the World Health Organization International Clinical Trials Registry Platform were searched for ongoing trials. No restrictions were placed on language or publication status when searching the electronic databases, however the search of Embase was restricted by date due to the Cochrane Centralised Search Project to identify all clinical trials and add them to CENTRAL. We included randomised controlled trials (RCTs) comparing different final-impression techniques and materials for treating people with complete dentures (CD) and removable partial dentures (RPD). For CD, we included trials that compared different materials or different techniques or both. In RPD for tooth-supported conditions, we included trials comparing the same material and different techniques, or different materials and the same technique. In tooth- and tissue-supported RPD, we included trials comparing the same material and different dual-impression techniques, and different materials with different dual-impression techniques. Two review authors independently, and in duplicate, screened studies for eligibility, extracted data, and assessed the risk of bias for each included trial. We expressed results as risk ratios (RR) for dichotomous outcomes, and as mean differences (MD) or standardised mean differences (SMD) for continuous outcomes, with 95% confidence intervals (CI), using the random-effects model. We constructed 'Summary of findings' tables for the main comparisons and outcomes (participant-reported oral health-related quality of life, quality of the denture, and denture border adjustments). We included nine studies in this review. Eight studies involved 485 participants with CD. We assessed six of the studies to be at high risk of bias, and two to be at low risk of bias. We judged one study on RPD with 72 randomised participants to be at high risk of bias.Overall, the quality of the evidence for each comparison and outcome was either low or very low, therefore, results should be interpreted with caution, as future research is likely to change the findings.Complete denturesTwo studies compared the same material and different techniques (one study contributed data to a secondary outcome only); two studies compared the same technique and different materials; and four studies compared different materials and techniques.One study (10 participants) evaluated two stage-two step, Biofunctional Prosthetic system (BPS) using additional silicone elastomer compared to conventional methods, and found no evidence of a clear difference for oral health-related quality of life, or quality of the dentures (denture satisfaction). The study reported that BPS required fewer adjustments. We assessed the quality of the evidence as very low.One study (27 participants) compared selective pressure final-impression technique using wax versus polysulfide elastomeric (rubber) material. The study did not measure quality of life or dentures, and found no evidence of a clear difference between interventions in the need for adjustments (RR 0.81, 95% CI 0.38 to 1.70). We assessed the quality of the evidence as very low.One study compared two stage-two step final impression with alginate versus silicone elastomer. Oral health-related quality of life measured by the OHIP-EDENT seemed to be better with silicone (MD 7.20, 95% CI 2.71 to 11.69; 144 participants). The study found no clear differences in participant-reported quality of the denture (comfort) after a two-week 'confirmation' period, but reported that silicone was better for stability and chewing efficiency. We assessed the quality of the evidence as low.Three studies compared single-stage impressions with alginate versus two stage-two step with elastomer (silicone, polysulfide, or polyether) impressions. There was no evidence of a clear difference in the OHIP-EDENT at one month (MD 0.05, 95% CI -2.37 to 2.47; two studies, 98 participants). There was no evidence of a clear difference in participant-rated general satisfaction with dentures at six months (MD 0.00, 95% CI -8.23 to 8.23; one study, 105 participants). We assessed the quality of the evidence as very low.One study compared single-stage alginate versus two stage-two step using zinc-oxide eugenol, and found no evidence of a clear difference in OHIP-EDENT (MD 0.50, 95% CI -2.67 to 3.67; 39 participants), or general satisfaction (RR 3.15, 95% CI 0.14 to 72.88; 39 participants) at six months. We assessed the quality of the evidence as very low.Removable partial denturesOne study randomised 72 participants and compared altered-cast technique versus one-piece cast technique. The study did not measure quality of life, but reported that most participants were satisfied with the dentures and there was no evidence of any clear difference between groups for general satisfaction at one-year follow-up (low-quality evidence). There was no evidence of a clear difference in number of intaglio adjustments at one year (RR 1.43, 95% CI 0.61 to 3.34) (very low-quality evidence). We conclude that there is no clear evidence that one technique or material has a substantial advantage over another for making complete dentures and removable partial dentures. Available evidence for the relative benefits of different denture fabrication techniques and final-impression materials is limited and is of low or very low quality. More high-quality RCTs are required.

  2. Changes in head and cervical-spine postures and EMG activities of masticatory muscles following treatment with complete upper and partial lower denture.

    PubMed

    Salonen, M A; Raustia, A M; Huggare, J A

    1994-10-01

    A clinical stomatognathic, cephalometric and electromyographic (EMG) study was performed in relation to 14 subjects (10 women, 4 men), each with an edentulous maxilla and residual mandibular dentition before and six months after treatment with complete upper and partial lower dentures. The mean age of the subjects was 54.4 years (range 43-64 years). The mean period of edentulousness and age of dentures were 22.5 years (range 15-33 years) and 14.1 (range 1.5-30 years), respectively. Natural head position was recorded (using a fluid-level method) and measured from cephalograms. EMG activity was measured in relation to masseter and temporal muscles. A decrease in clinical dysfunction index was noted in 12 of 14 subjects (86%). There was no change in cervical inclination, but a slight extension of the head was noted after treatment. Rapid recovery of the masticatory muscles was reflected in increased EMG activity, especially when biting in the maximal intercuspal position. In cases of edentulous maxilla and residual mandibular anterior dentition, treatment with a complete upper and lower partial denture had a favorable effect on craniomandibular disorders and masticatory-muscle function.

  3. An overview of removable partial overdentures.

    PubMed

    McDermott, I G; Samant, A

    1990-02-01

    As an alternative to complete dentures, overdentures are well established as a sound therapeutic modality for patients with terminal dentition. By utilizing natural tooth roots and their periodontal structures to aid in support, overdentures maintain proprioceptive mediation and a mechanism for masticatory force vectors that favor bone retention over bond resorption. The degree of stability enhancement and denture retention from retained roots varies with the design and environment of the prosthesis. This article reviews various aspects of removable partial over-denture use.

  4. Digital Denture Fabrication in Pre- and Postdoctoral Education: A Survey of U.S. Dental Schools.

    PubMed

    Fernandez, Monica A; Nimmo, Arthur; Behar-Horenstein, Linda S

    2016-01-01

    To survey chairs of prosthodontics or restorative departments and program directors of postdoctoral prosthodontic programs in the United States regarding digital denture fabrication. The key objectives of the survey were to identify the current trends in complete denture fabrication using CAD/CAM technology and to determine how and to what extent this technique is taught and used in U.S. pre- and postdoctoral prosthodontic programs. An invitation to participate in an online survey was sent to 52 prosthodontics/restorative chairs of U.S. dental schools and to all of the 50 program directors of postdoctoral prosthodontics programs. A version of the survey with the same questions was sent to a national sample of prosthodontics/restorative chairs and program directors of postdoctoral prosthodontics. The 20-item survey took approximately 15 minutes to complete. Dependent samples paired t-test was run on items that were the same in both surveys. The response rate for the survey was 63% for department chairs and 44% for program directors. All respondents with the exception of one department chair were aware of CAD/CAM technology used for denture fabrication. More than half of the program directors (52.4%) compared to 12.1% of chairs have incorporated some aspects of CAD/CAM denture fabrication technology into their curriculum. When asked if the fabrication cost prevented introducing this technology in the predoctoral/postdoctoral curriculum, 52.4% of the department chairs affirmed this response compared to 12.1% of the program directors. There was a significant difference between groups when asked if they had incorporated the CAD/CAM denture fabrication technique into the postgraduate/predoctoral curriculum. Department chairs reported less usage of CAD/CAM technology. Only 12.1% of department chairs reported using some aspects of CAD/CAM technology in the predoctoral curriculum compared to 52.4% in the postdoctoral curriculum (F = 13.528, p ≤ 0.001). While this technology is used in four predoctoral clinics, none of the chairs reported including CAD/CAM denture fabrication in their preclinical complete denture courses. For the schools using the technology, 33.3% of postdoctoral and 30.3% of predoctoral programs use it to make a denture with a try-in step; however, 19% of the postdoctoral and 18.2% of predoctoral programs process the dentures without a try-in appointment. Slightly less than half (42.9%) of graduate programs are using the technology to make just the denture bases. Only a small proportion (10% or less) of the total number of dentures processed in post- and predoctoral programs are made using CAD/CAM technology. The proportion of postdoctoral programs that process cases using CAD/CAM technology was significantly higher than in predoctoral programs (F = 5.106, p ≤ 0.028). Many schools indicated that they are in a "trial phase" to evaluate the technique, especially at the predoctoral level. Also, 19% (n = 4) of postdoctoral and 15.2% (n = 5) of predoctoral respondents have created continuing education courses. Of postdoctoral programs, 38.1% (n = 8) plan to introduce this technology at some point in the near future (next 1 to 4 years); 27.3% of predoctoral programs plan to as well. All program directors and department chairs who participated in the survey are aware of this technology with the exception of one department chair. More than half of the program directors reported that they have incorporated this technology in their curricula compared to only 12% of department chairs. Currently, only 10% or less of complete denture cases are processed using the CAD/CAM technology, at either the post- or predoctoral levels. Both groups reported that the main use of this technology is for the fabrication of denture bases and for processing dentures including the try-in step. The majority of respondents in both groups indicated they plan to add digital denture fabrication into their curricula within the next 1 to 4 years. © 2015 by the American College of Prosthodontists.

  5. An audit to assess the quality and efficiency of complete and partial dentures delivered by junior hospital staff.

    PubMed

    Kalsi, Harpoonam J; Wang, Yon Jon; Bavisha, Kalpesh; Bartlett, David

    2010-03-01

    The average number of visits for the construction of metal-based and acrylic dentures by junior hospital staff was 10 visits. Our hypothesis was that supervision would optimise the number of visits and reduce any need for remakes. The first audit cycle was retrospective and included all patients treated by SHOs in the Prosthodontics Department. The standard of care was compared to the British Society for the Study of Prosthetic Dentistry. The re-audit showed that the time taken to completion was reduced by 2 visits for both denture types and the average length of time was reduced from 31 weeks to 22 weeks. These improvements were directly related to improved supervision by senior staff.

  6. [Dissertations 25 year after date 41. Older people's adaptability].

    PubMed

    de Baat, C; Gerritsen, A E; van der Putten, G J; van der Maarel-Wierink, C D

    2015-09-01

    In 1990, the thesis 'Removable complete dentures in older people, an issue dealing with adaptability?' was published. Among other things, this thesis aimed at finding a method of measuring older people's adaptability to removable complete dentures. Its conclusion was that a subscale of the "Beoordelingsschaal voor Oudere Patiënten" (Rating scale for older patients) had predictive value. Subsequently, only a few research projects on this topic have been carried out. They dealt with demonstrated adaptation achieved after treatment, the realised adaptation. The results were disappointing. Ever since the availability of endosseous oral implants, research into adaptability to conventional removable complete dentures seems less relevant. During the last decades, inquiries into a method of measuring treatment effectiveness has focused on older people's quality of life and general health condition. However, to assess with respect to oral health care an older person's general health condition and load-taking capacity adequately, some experience is indispensable.

  7. Clinical comparison of masticatory performance and electromyographic activity of patients with complete dentures, overdentures, and natural teeth.

    PubMed

    Rissin, L; House, J E; Manly, R S; Kapur, K K

    1978-05-01

    In this study, which is the first of its kind, it has been shown that overdenture patients, when compared to complete denture patients, while chewing a test food for a constant number of strokes, expended an equivalent amount of muscle effort, chewed more slowly and efficiently, and evidenced significantly better masticatory performance by producing an increased volume of fine test food particles. These findings provide a sound justification for the extra effort required to retain some natural teeth to provide overdenture services to patients. The fact that patients can masticate food more efficiently with overdentures than with complete dentures justifies the increased cost and time involved in their construction. The longitudinal effects that overdentures have on the basic physiopathologic processed involved in the progression of ridge resorption and the advantages of maintaining periodontal proprioception also should be studied.

  8. Contact allergy to denture materials in the burning mouth syndrome.

    PubMed

    van Joost, T; van Ulsen, J; van Loon, L A

    1988-02-01

    Several factors may be responsible for stomatitis in general and the burning mouth syndrome in particular. The results of patch testing are reported in 4 patients with burning mouth symptoms thought to be due to sensitization to denture material. 2 patients reacted to substances in Luxene dentures, but the allergens were not identified. In a 3rd patient, sensitization was found to monomeric methyl methacrylate. The other patient gave positive patch tests to epoxy resin (and bisphenol A), probably present in glue used for repair of dental plates. To obtain a complete diagnosis in cases of suspected contact stomatitis due to allergens in dentures, a reliable standard test series is required.

  9. Oral manifestations of diabetes mellitus in complete denture wearers.

    PubMed

    Cristina de Lima, Danielle; Nakata, Gislaine Cristina; Balducci, Ivan; Almeida, Janete Dias

    2008-01-01

    The oral mucosa has been reported to show a variety of changes in subjects with diabetes mellitus. The purpose of this study was to compare diabetic and nondiabetic subjects wearing complete dentures with regard to salivary flow, salivary buffering capacity, denture retention, and oral mucosal lesions. Sixty subjects, 30 with and 30 without a diagnosis of diabetes, were matched for gender, race, and age. Salivary flow, salivary buffering capacity, glycemia, blood pressure, presence of mucosal lesions, denture retention, use of medications, and behavioral factors (controlled or uncontrolled diet, alcohol consumption, and smoking) reported by the subjects, were evaluated. For the salivary buffering capacity test, 1 mL of saliva was pipetted into a test tube containing 3 mL 0.005 N of hydrochloric acid, and the pH was measured with indicator strips. Group differences were statistically analyzed using the Student t test and the Mann-Whitney test for quantitative variables and the chi-square test for qualitative variables (alpha =.05). Mean (SD) salivary flow was 1.14 (0.87) mL/min in the nondiabetic subjects and 0.95 (0.61) mL/min in the diabetic subjects. Evaluation of self-reported denture retention revealed no significant difference between groups. Denture retention was observed in 66.7% (20/30) of the control group and in 50% (15/30) of the diabetic group. The prevalence of mucosal lesions was 90% (27/30) in the control group and 83.3% (25/30) in the diabetic group. Salivary buffering capacity was 5.80 (0.85) in the control group and 5.26 (0.83) in the diabetic group (P=.017). Within the limitations of this study, no significant differences were observed in salivary flow, denture retention, or oral lesions in diabetic and nondiabetic subjects.

  10. Epidemiological survey on edentulousness.

    PubMed

    Reddy, N Simhachalam; Reddy, Nallala Amarendra; Narendra, R; Reddy, Sashi Deepth

    2012-07-01

    India has a large geriatric population of 77 millions, comprising 7.7% of its total population. One of the major handicaps in the elderly is loss of teeth, affecting their mastication, dietary intake and nutritional status. The present study was planned to assess the level of edentulousness, cause of edentulousness, denture wearing and denture needs of the middle and elderly in the society and study was correlated between habits and socioeconomic variables, diet and body mass index (BMI). A total of 500 subjects (random sampling) from dental outpatient were studied. A prepared questionnaire was developed, explained, interviewed and questions were filled personally. The level of edentulousness was found to be high in the subjects with low socioeconomic status and in advancing age with no significant difference between male and females. Another finding was very low level of denture wearing of 62% needing complete denture and partial denture only 10.4% of subjects wearing dentures. Mixed diet population had higher level of edentulousness compared with vegetarians. The BMI was correlated with level of edentulousness. The study clearly showed that there is lack of dental awareness, so dental education and motivation in very important. The study concludes that the need for prosthodontics care will increase due to the increase in life span. This study is clinically significant with regard to knowing the root cause of edentulism, either partial or complete. Out of 62% tooth loss, dental caries (37.4%) topped the cause for tooth loss followed by combination of dental caries and periodontal disease (12.2%).

  11. Does a mandibular overdenture improve nutrient intake and markers of nutritional status better than conventional complete denture? A systematic review and meta-analysis

    PubMed Central

    Yamazaki, Toru; Martiniuk, Alexandra LC; Irie, Koichiro; Sokejima, Shigeru; Lee, Crystal Man Ying

    2016-01-01

    Objectives The need for denture treatment in public health will increase as the population ages. However, the impact of dentures on nutrition, particularly overdenture treatment, remains unclear although the physical and psychological effects are known. We investigated whether treatment with a mandibular implant supported overdenture improves nutrient intake and markers of nutritional status better than a conventional complete denture in edentulous patients. Design Systematic review and meta-analysis. Methods Medline, EMBASE and the Cochrane Central Register of Controlled Trials were searched for eligible studies published up to April 2016. We included studies which compared the treatment effect of an overdenture to conventional denture on nutrition, in which primary outcomes included changes in intake of macronutrients and/or micronutrients and/or indicators of nutritional status. Two reviewers independently evaluated eligible studies and assessed the risk of bias. We used a fixed effects model to estimate the weighted mean difference (WMD) and 95% CI for change in body mass index (BMI), albumin and serum vitamin B12 between overdenture and conventional denture 6 months after treatment. Results Of 108 eligible studies, 8 studies involving 901 participants were included in the narrative appraisal. Four studies reported changes in markers of nutritional status and nutrient intake after treatment with a prosthetic, regardless of type. In a meta-analysis of 322 participants aged 65 years or older from three studies, pooled analysis suggested no significant difference in change in BMI between an overdenture and conventional denture 6 months after treatment (WMD=−0.18 kg/m2 (95% CI −0.52 to 0.16)), and no significant difference in change in albumin or vitamin B12 between the two treatments. Conclusions The modifying effect of overdenture treatment on nutritional status might be limited. Further studies are needed to evaluate the effectiveness and efficacy of denture treatments. PMID:27489156

  12. Video-based Learning Versus Traditional Method for Preclinical Course of Complete Denture Fabrication.

    PubMed

    Fayaz, Amir; Mazahery, Azita; Hosseinzadeh, Mohammad; Yazdanpanah, Samane

    2015-03-01

    Advances in computer science and technology allow the instructors to use instructional multimedia programs to enhance the process of learning for dental students. The purpose of this study was to determine the effect of a new educational modality by using videotapes on the performance of dental students in preclinical course of complete denture fabrication. This quasi-experimental study was performed on 54 junior dental students in Shahid Beheshti University of Medical Sciences (SBMU). Twenty-five and 29 students were evaluated in two consecutive semesters as controls and cases, respectively for the same course. The two groups were matched in terms of "knowledge about complete denture fabrication" and "basic dental skills" using a written test and a practical exam, respectively. After the intervention, performance and clinical skills of students were assessed in 8 steps. Eventually, a post-test was carried out to find changes in knowledge and skills of students in this regard. In the two groups with the same baseline level of knowledge and skills, independent T-test showed that students in the test group had a significantly superior performance in primary impression taking (p= 0.001) and primary cast fabrication (p= 0.001). In terms of anterior teeth set up, students in the control group had a significantly better performance (p= 0.001). Instructional videotapes can aid in teaching fabrication of complete denture and are as effective as the traditional teaching system.

  13. Comparison between complete denture and implant-retained overdenture: effect of different mucosa thickness and resiliency on stress distribution.

    PubMed

    Assunção, Wirley Gonçalves; Barão, Valentim Adelino Ricardo; Tabata, Lucas Fernando; de Sousa, Edson Antonio Capello; Gomes, Erica Alves; Delben, Juliana Aparecida

    2009-12-01

    The effect of different mucosa characteristics on stress distribution of complete dentures and overdentures remains unknown. The aim of this study was to evaluate the effect of different mucosa thickness and resiliency on the stress distribution of complete dentures and implant-retained overdentures using a two-dimensional finite element analysis. Representative models of the edentulous mandible were constructed on AutoCAD software according to the groups' characteristics. In group CD, a model of the edentulous mandible supporting a complete denture was obtained while in group IO, a model of edentulous mandible supporting an overdenture over two unsplinted implants with an o' ring system was constructed. In each group, mucosa assumed three characteristics of thickness (1, 3 and 5 mm) corresponding to the resiliencies hard, resilient and soft respectively. Evaluation was performed on Ansys software with 100N vertical load applied on central incisor teeth. The principal stress was used as analysis criteria. Group IO showed higher stress values than group CD regardless of mucosal thickness and resiliency. Stress decreased at the supporting tissues in both groups as the thickness and resiliency of mucosa increased. In relation to the supporting tissues, cortical bone showed the highest stress values. It was concluded that the use of an attachment system increases stress values and the thickness and resiliency of mucosa influence more on these values.

  14. Combined effect of new complete dentures and simple dietary advice on nutritional status in edentulous patients: study protocol for a randomized controlled trial.

    PubMed

    Komagamine, Yuriko; Kanazawa, Manabu; Iwaki, Maiko; Jo, Ayami; Suzuki, Hiroyuki; Amagai, Noriko; Minakuchi, Shunsuke

    2016-11-09

    Individuals who are edentulous have a lower intake of fruit, vegetables, fiber, and protein compared with their dentate counterparts because tooth loss is accompanied by a decrease in ability to chew. Whether or not a combination of prosthetic rehabilitation and simple dietary advice produces improvement in dietary intake among edentulous persons is unclear. We aim to investigate the effect of a simultaneous combination of simple dietary advice delivered by dentists and provision of new complete dentures on dietary intake in edentulous individuals who request new dentures. Through a double-blinded, parallel, randomized controlled trial in which 70 edentate persons who request new complete dentures will be enrolled, eligible study participants will be randomly allocated to either a dietary intervention group receiving dietary advice or to a control group receiving only advice on the care and maintenance of dentures. Outcome measures include daily intake of nutrients and food items, assessed using a brief self-administered diet history questionnaire; antioxidant capacity, determined using blood and urine samples; nutritional status, assessed with the Mini-Nutritional Assessment-Short Form; oral health-related quality of life, assessed with the Japanese version of the Oral Health Impact Profile-EDENT and the Geriatric Oral Health Assessment Index; subjective chewing ability; masticatory performance, assessed using a color-changeable chewing gum and a gummy jelly; patient self-assessment of dentures; mild cognitive impairment, assessed with the Japanese version of the Montreal Cognitive Assessment; and functional capacity, assessed with the Japan Science and Technology Agency Index of Competence. Outcome measures, except for antioxidant capacity, are to be implemented at three time points: at baseline and at 3 and 6 months following intervention. Antioxidant capacity data are to be collected twice: at baseline and at 3 months following intervention. Differences between the groups at 3 and 6 months and within-group changes are to be compared using the paired t test. Simple dietary advice that can be implemented by a dentist would be more practical in clinical practice than tailored dietary counseling. The results of this study will provide beneficial information on dietary intake changes for both edentulous individuals requesting new complete dentures and dentists. University Hospital Medical Information Network Center Unique Trial Number: UMIN000017879 . Registered on 12 June 2015.

  15. On occlusal forces in dentitions with implant-supported fixed cantilever prostheses.

    PubMed

    Falk, H

    1990-01-01

    The main aims of this thesis were (1) to study the functional characteristics of dentitions with mandibular implant-supported fixed cantilever prostheses - IFCP s- occluding with complete dentures, (2) to study in detail the magnitudes and distributions of axially directed closing and chewing forces in such dentitions, (3) to study the influence of number and distribution of occlusal contacts on the magnitude and distribution of closing and chewing forces, (4) to assess the vertical bending moment and the resulting vertical bending stress in the cantilever joints and (5) to find out whether the force distribution over the cantilever beams and the resulting vertical bending stress in the cantilever joint are influenced by the type of prosthetic construction in the opposing jaw. Closing and chewing forces were registered in altogether seventeen subjects by means of miniature strain gauge transducers mounted bilaterally and symmetrically in performed matrices in prosthetic appliances. Four, six or eight transducers, evenly distributed over the tooth-arch, permitted registrations of axially directed occlusal forces in several occluding areas simultaneously. In Papers I-IV, the implant-supported prostheses were installed in the mandible and occluded with complete dentures. In Paper V, group A, the fixture-supported prostheses were installed in the maxilla and occluded with tooth-supported fixed partial dentures whereas in group B, the arrangements were analogous to those in Papers I-IV. All subjects exhibited a rhythmic chewing pattern and preferred one side for chewing although both sides were used. Most chewing sequences were terminated with swallowing with occlusal force development. The mean total forces acting over the tooth-arch varied somewhat between groups and occlusal arrangements but averaged 350 and 170 N for closing and chewing respectively. Closing and chewing forces increased distally along the cantilever beams when occluding with complete dentures and decreased distally when occluding with fixed partial dentures. The distally increasing force distribution pattern could be altered to a distally decreasing force distribution pattern by infraoccluding the second cantilever unit by as little as 100 microns. Calculated vertical bending moments and stresses in the cantilever joints of the preferred chewing sides created by closing and chewing forces were larger in dentitions where the IFCP occluded with a complete denture than in dentitions where the IFCP occluded with a tooth-supported fixed partial denture.

  16. Space requirement of a prefabricated bar on two interforaminal implants: a prospective clinical study.

    PubMed

    Albrecht, Dominic; Ramierez, Ami; Kremer, Urs; Katsoulis, Joannis; Mericske-Stern, Regina; Enkling, Norbert

    2015-02-01

    This clinical study measured the dimensional changes of existing lower complete dentures due to the integration of a prefabricated implant bar. Additionally, the impact of this dimensional change on patient satisfaction and oral function was analyzed. Twenty edentulous patients (10 men/10 women; aged 65.9 ± 11.8 years) received two interforaminal implants. Subsequent to surgery, a chair side adapted, prefabricated bar (SFI Bar(®), C+M, Biel, Switzerland) was inserted, and the matrix was polymerized into the existing lower denture. The change of the denture's lingual dimension was recorded by means of a bicolored, silicone denture duplicate that was sectioned in the oro-vestibular direction in the regions of the symphysis (S) and the implants (I-left, I-right). On the sections, the dimensional increase was measured using a light microscope. Six months after bar insertion, patients answered a standardized questionnaire. All dentures exhibited increased lingual volume, more extensively at S than at I (P = 0.001). At S, the median diagonal size of the denture was doubled (+4.33 mm), and at I, the median increase was 50% (I-left/-right = +2.66/+2.62 mm). The original denture size influenced the volume increase (P = 0.024): smaller dentures led to a larger increase. The amount of denture increase did not have negative impact on either self-perceived oral function or patient satisfaction. Approximately, 95% of the patients were satisfied with the treatment results. The lingual size of a lower denture was enlarged by the integration of a prefabricated bar without any negative side effects. Thus, this attachment system is suitable to convert an existing full denture into an implant-supported overdenture. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Clinical interpretation of a masticatory normative indicator analysis of masticatory function in subjects with different occlusal and prosthodontic status.

    PubMed

    Witter, Dick J; Woda, Alain; Bronkhorst, Ewald M; Creugers, Nico H J

    2013-05-01

    To analyse the masticatory function of subjects characterised by different occlusal and prosthodontic status. Using Optosil(®) as a test food, the masticatory normative indicator (MNIOPT) was used to differentiate between sufficient ('normal') and impaired masticatory function. Outcomes of occlusal force and masticatory tests were aggregated from three earlier studies dealing with four denture groups and three natural dentition groups. The four denture groups had a complete removable dental prosthesis in the upper jaw, and displayed one of the four following lower jaw prosthodontic rehabilitations: (i) complete removable dental prosthesis on a low mandible; (ii) complete removable dental prosthesis on a higher mandible; (iii) overdenture on natural roots; and (iv) overdenture on dental implants. The three natural dentition groups were: (i) shortened dental arch; (ii) complete dentition in older participants, and (iii) complete dentition in younger participants. All participants were women. They performed the same tests twice, and outcomes were averaged. A MNIOPT value of 3.68 mm was determined from the participants with complete natural dentitions. Applying the MNIOPT to the participants in the denture groups pointed at a considerable chance for impaired masticatory function, except for participants in the overdenture -implants group. The four denture groups compensated for reduced masticatory efficiency by increased number of masticatory cycles and prolonged mastication time until 'swallowing'. Nevertheless, they also 'swallowed' larger particles compared to the complete dentition group. For a given patient or for a group of subjects with specific dental conditions, MNI enables to discriminate between a sufficient ('normal') and an impaired masticatory function. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. The influence of polishing techniques on pre-polymerized CAD\\CAM acrylic resin denture bases

    PubMed Central

    Alammari, Manal Rahma

    2017-01-01

    Background Lately, computer-aided design and computer-aided manufacturing (CAD/CAM) has broadly been successfully employed in dentistry. The CAD/CAM systems have recently become commercially available for fabrication of complete dentures, and are considered as an alternative technique to conventionally processed acrylic resin bases. However, they have not yet been fully investigated. Objective The purpose of this study was to inspect the effects of mechanical polishing and chemical polishing on the surface roughness (Ra) and contact angle (wettability) of heat-cured, auto-cured and CAD/CAM denture base acrylic resins. Methods This study was conducted at the Advanced Dental Research Laboratory Center of King Abdulaziz University from March to June 2017. Three denture base materials were selected: heat cure poly-methylmethacrylate resin, thermoplastic (polyamide resin) and (CAD\\CAM) denture base resin. Sixty specimens were prepared and divided into three groups, twenty in each. Each group was divided according to the polishing techniques into (Mech P) and (Chem P), ten specimens in each; surface roughness and wettability were investigated. Data were analyzed by SPSS version 22, using one-way ANOVA and Pearson coefficient. Results One-way analysis of variance (ANOVA) and post hoc tests were used for comparing the surface roughness values between three groups which revealed a statistical significant difference between them (p1<0.001). Heat-cured denture base material of (Group I) in both methods, showed the highest mean surface roughness value (2.44±0.07, 2.72±0.09, Mech P and Chem P respectively); while CAD\\CAM denture base material (group III) showed the least mean values (1.08±0.23, 1.39±0.31, Mech P and Chem P respectively). CAD/CAM showed the least contact angle in both polishing methods, which were statistically significant at 5% level (p=0.034 and p<0.001). Conclusion Mechanical polishing produced lower surface roughness of CAD\\CAM denture base resin with superior smooth surface compared to chemical polishing. Mechanical polishing is considered the best effective polishing technique. CAD/CAM denture base material should be considered as the material of choice for complete denture construction in the near future, especially for older dental patients with changed salivary functions, because of its wettability. PMID:29238483

  19. The influence of polishing techniques on pre-polymerized CAD\\CAM acrylic resin denture bases.

    PubMed

    Alammari, Manal Rahma

    2017-10-01

    Lately, computer-aided design and computer-aided manufacturing (CAD/CAM) has broadly been successfully employed in dentistry. The CAD/CAM systems have recently become commercially available for fabrication of complete dentures, and are considered as an alternative technique to conventionally processed acrylic resin bases. However, they have not yet been fully investigated. The purpose of this study was to inspect the effects of mechanical polishing and chemical polishing on the surface roughness (Ra) and contact angle (wettability) of heat-cured, auto-cured and CAD/CAM denture base acrylic resins. This study was conducted at the Advanced Dental Research Laboratory Center of King Abdulaziz University from March to June 2017. Three denture base materials were selected: heat cure poly-methylmethacrylate resin, thermoplastic (polyamide resin) and (CAD\\CAM) denture base resin. Sixty specimens were prepared and divided into three groups, twenty in each. Each group was divided according to the polishing techniques into (Mech P) and (Chem P), ten specimens in each; surface roughness and wettability were investigated. Data were analyzed by SPSS version 22, using one-way ANOVA and Pearson coefficient. One-way analysis of variance (ANOVA) and post hoc tests were used for comparing the surface roughness values between three groups which revealed a statistical significant difference between them (p 1 <0.001). Heat-cured denture base material of (Group I) in both methods, showed the highest mean surface roughness value (2.44±0.07, 2.72±0.09, Mech P and Chem P respectively); while CAD\\CAM denture base material (group III) showed the least mean values (1.08±0.23, 1.39±0.31, Mech P and Chem P respectively). CAD/CAM showed the least contact angle in both polishing methods, which were statistically significant at 5% level (p=0.034 and p<0.001). Mechanical polishing produced lower surface roughness of CAD\\CAM denture base resin with superior smooth surface compared to chemical polishing. Mechanical polishing is considered the best effective polishing technique. CAD/CAM denture base material should be considered as the material of choice for complete denture construction in the near future, especially for older dental patients with changed salivary functions, because of its wettability.

  20. [Effects of maxillary distraction osteogenesis on the velopharyngeal configuration of cleft palate patients].

    PubMed

    Wang, Xiao-xia; Wang, Xing; Yi, Biao; Li, Zi-li; Liang, Cheng

    2005-12-18

    To study the effects of internal maxillary distraction osteogenesis(DO) on the velopharyngeal configuration of cleft palate patients. Ten patients with severe maxillary hypoplasia secondary to cleft lip and palate patients (7 males and 3 females, average age 20.1 years old) had undertaken high step LeFort I osteotomy, and internal maxillary distraction devices were applied to advance the maxilla. Before surgery, when DO was completed and 6 months after DO was completed, oriented lateral cephalograms at rest position of each patient were taken, and 6 measure indexes of velopharyngeal configuration were collected and analyzed. All patients had successfully accomplished maxillary DO and the maxilla had been averagely advanced 11.3 mm. PNS-PhW, C-PhW, UL and ANS-PNS-T had all significantly increased, and UD had significantly decreased when DO was completed and 6 months after DO was completed as compared with pre-surgery. No significant linear correlation was found between maxilla advancement distance and velopharyngeal configuration changes. Correction of maxillary hypoplasia secondary to cleft palate surgery by using internal maxillary DO can increase the velopharyngeal cavity depth, and may impair velopharyngeal competence, but the compensatory changes of velopharyngeal soft tissue can alleviate this impairment to certain extent.

  1. Assessment of Candida species colonization and denture-related stomatitis in bar- and locator-retained overdentures.

    PubMed

    Kilic, Kerem; Koc, Ayse Nedret; Tekinsen, Fatma Filiz; Yildiz, Pinar; Kilic, Duygu; Zararsiz, Gokmen; Kilic, Erdem

    2014-10-01

    The aim of this study was to assess the prevalence of denture-related stomatitis (DRS) in different attachment-retained overdenture wearers and its association with particular colonizing Candida species. Thirty-seven edentulous patients with implant-supported maxillary or mandibular overdentures were enrolled. A full clinical history was obtained, including details of patients' oral hygiene practices and the levels of erythema based on Newton's classification scale. Swabs were taken from the palate and investigated mycologically to identify the yeast colonies. Quantitative and qualitative microbiological assessments were performed, which included recording the total numbers of colonies (cfu), their color, and their morphological characteristics. Significant differences were found in cfu values between the attachment and inner surfaces of locator- and bar-retained overdentures (P < .05). Candida albicans was the most common species in both evaluations, being isolated from 81.3% of bar-retained overdentures and 38.1% of locator-retained overdentures. DRS developed in all patients using bar-retained overdentures but in only 71.4% of those using locator-retained overdentures. No statistically significant relationship was found between bar and locator attachments according to smoking habit, overnight removal, or plaque and gingival indices (P > .05).

  2. Zirconia removable telescopic dentures retained on teeth or implants for maxilla rehabilitation. Three-year observation of three cases.

    PubMed

    Zafiropoulos, Gregory-George; Rebbe, Jochen; Thielen, Ulrich; Deli, Giorgio; Beaumont, Christian; Hoffmann, Oliver

    2010-01-01

    This report addresses maxillary restoration with removable telescopic crown-retained palatal free dentures. One patient with 7 natural teeth (PERIO), a second patient with 6 dental implants (IMPL), and a third patient with 2 natural teeth and 4 dental implants (IMPL-PERIO) were treated. Zirconia copings for natural teeth and individual zirconia implant abutments were fabricated in CAD/CAM and used as primary crowns. Electroformed gold copings were used as secondary telescopes. All maxilla supraconstructions were fabricated with zirconia and CAD/CAM. Patients were monitored during a 3-year period; all teeth and implants survived, and no biological or mechanical complications occurred. The peri-implant and periodontal conditions were healthy. While recognizing the limitations of this report, results showed that fabricating removable zirconia structures by means of CAD/CAM can yield highly functional and esthetic results. Galvanoforming technology is the preferable means of fabricating secondary crowns. The combination of these techniques and materials results in a prosthetic reconstruction of high quality, good fit, and biocompatibility. Long-term studies of large populations are necessary to investigate the clinical properties of the material utilized in this type of construction.

  3. Nutritional status, dietary intake and oral quality of life in elderly complete denture wearers.

    PubMed

    Cousson, Pierre Yves; Bessadet, Marion; Nicolas, Emmanuel; Veyrune, Jean-Luc; Lesourd, Bruno; Lassauzay, Claire

    2012-06-01

    The prevalence of malnutrition increases with age because of many factors. Edentulousness leads to the avoidance of many types of foods. The aim of this study was to determine whether elderly complete denture wearers have a higher risk of malnutrition than dentate controls. A Mini-Nutritional Assessment (MNA) and a 3-day dietary record were compiled for a group of fully dentates (21 women and 29 men; mean age 70.1 ± 6.1) and for a group of complete denture wearers (31 women and 16 men; mean age 70.1 ± 8.1). Socio-demographic data and scores on the General Oral Health Assessment Index (GOHAI) questionnaire were collected. Inter-group comparison of MNA scores showed that more subjects in the edentulous group (21.3%) risked malnutrition than in the dentate group (0%). The variability of the MNA could be explained for 22% by dental status, 7% by loneliness and 4% by the GOHAI score (regression analysis). Both groups had insufficient energy intakes and deficits in vitamins and micronutrients; moreover, edentulous subjects had lower intakes than dentate subjects. The use of conventional dentures increases the risk of malnutrition in the elderly. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  4. Oral Rehabilitation of an Osteopetrosis Patient with Osteomyelitis

    PubMed Central

    Celakil, Tamer; Dogan, Merve; Rohlig, Bilge Gokcen; Evlioglu, Gulumser; Keskin, Haluk

    2016-01-01

    Osteopetrosis is a congenital disorder characterized by increasing osteoclastic function resulting in osteomyelitis in the jaws. Orofacial findings in osteopetrosis patients are unerupted, malformed, or delayed teeth and many dental caries due to vulnerable enamel and dentin and osteomyelitis. Many reports have described that maxilla is an uncommon site of occurrence for osteomyelitis due to cortical bone morphology and collateral circulation. This report aims to discuss clinical features and prosthodontic management of a patient with clinical features of adult form of osteopetrosis and osteomyelitis in both jaws. The patient has reported better masticatory and speech efficiency with removable dentures in maxillary and mandibular jaw and also self-esteem improvement and family interaction. PMID:27148461

  5. Oral Rehabilitation of an Osteopetrosis Patient with Osteomyelitis.

    PubMed

    Celakil, Tamer; Dogan, Merve; Rohlig, Bilge Gokcen; Evlioglu, Gulumser; Keskin, Haluk

    2016-01-01

    Osteopetrosis is a congenital disorder characterized by increasing osteoclastic function resulting in osteomyelitis in the jaws. Orofacial findings in osteopetrosis patients are unerupted, malformed, or delayed teeth and many dental caries due to vulnerable enamel and dentin and osteomyelitis. Many reports have described that maxilla is an uncommon site of occurrence for osteomyelitis due to cortical bone morphology and collateral circulation. This report aims to discuss clinical features and prosthodontic management of a patient with clinical features of adult form of osteopetrosis and osteomyelitis in both jaws. The patient has reported better masticatory and speech efficiency with removable dentures in maxillary and mandibular jaw and also self-esteem improvement and family interaction.

  6. Development of an Antifungal Denture Adhesive Film for Oral Candidiasis Utilizing Hot Melt Extrusion Technology

    PubMed Central

    Park, Jun-Bom; Prodduturi, Suneela; Morott, Joe; Kulkarni, Vijay I.; Jacob, Melissa R.; Khan, Shabana I.; Stodghill, Steven P.; Repka, Michael A.

    2017-01-01

    Objectives The overall goal of this research was to produce a stable hot-melt extruded “Antifungal Denture Adhesive film” (ADA) system for the treatment of oral candidiasis. Methods The ADA systems with hydroxypropyl cellulose (HPC) and/or polyethylene oxide (PEO) containing clotrimazole (10%) or nystatin (10%) were extruded utilizing a lab scale twin-screw hot-melt extruder. Rolls of the antifungal-containing films were collected and subsequently die-cut into shapes adapted for a maxillary (upper) and mandibular (lower) denture. Results DSC and PXRD results indicated that the crystallinity of both APIs was changed to amorphous phase after hot-melt extrusion. The ADA system, containing blends of HPC and PEO, enhanced the effectiveness of the antimicrobials a maximum of 5-fold toward the inhibition of cell adherence of C. albicans to mammalian cells/Vero cells. Remarkably, a combination of the two polymers without drug also demonstrated a 38% decrease in cell adhesion to the fungi due to the viscosity and the flexibility of the polymers. Drug-release profiles indicated that both drug concentrations were above the minimum inhibitory concentration (MIC) for C. albicans within 10 minutes and was maintained for over 10 hours. In addition, based on the IC50 and MIC values, it was observed that the antifungal activities of both drugs were increased significantly in the ADA systems. Conclusions Based on these findings, the ADA system may be used for primary, prophylaxis or adjunct treatment of oral or pharyngeal candidiasis via controlled-release of the antifungal agent from the polymer matrix. PMID:25169007

  7. Development of an antifungal denture adhesive film for oral candidiasis utilizing hot melt extrusion technology.

    PubMed

    Park, Jun-Bom; Prodduturi, Suneela; Morott, Joe; Kulkarni, Vijay I; Jacob, Melissa R; Khan, Shabana I; Stodghill, Steven P; Repka, Michael A

    2015-01-01

    The overall goal of this research was to produce a stable hot-melt extruded 'Antifungal Denture Adhesive film' (ADA) system for the treatment of oral candidiasis. The ADA systems with hydroxypropyl cellulose (HPC) and/or polyethylene oxide (PEO) containing clotrimazole (10%) or nystatin (10%) were extruded utilizing a lab scale twin-screw hot-melt extruder. Rolls of the antifungal-containing films were collected and subsequently die-cut into shapes adapted for a maxillary (upper) and mandibular (lower) denture. Differential scanning calorimeter and powder X-ray diffraction results indicated that the crystallinity of both APIs was changed to amorphous phase after hot-melt extrusion. The ADA system, containing blends of HPC and PEO, enhanced the effectiveness of the antimicrobials a maximum of fivefold toward the inhibition of cell adherence of Candida albicans to mammalian cells/Vero cells. Remarkably, a combination of the two polymers without drug also demonstrated a 38% decrease in cell adhesion to the fungi due to the viscosity and the flexibility of the polymers. Drug-release profiles indicated that both drug concentrations were above the minimum inhibitory concentration (MIC) for C. albicans within 10 min and was maintained for over 10 h. In addition, based on the IC50 and MIC values, it was observed that the antifungal activities of both drugs were increased significantly in the ADA systems. Based on these findings, the ADA system may be used for primary, prophylaxis or adjunct treatment of oral or pharyngeal candidiasis via controlled release of the antifungal agent from the polymer matrix.

  8. Functional evaluation of a CAD/CAM prosthesis for immediate defect repair after total maxillectomy: a case series of 18 patients with maxillary sinus cancer.

    PubMed

    Jiang, Fei-Fei; Hou, Yan; Lu, Li; Ding, Xiao-Xu; Li, Wei; Yan, Ai-Hui

    2015-01-01

    To evaluate the facial profiles and functional recovery of 18 patients treated by a computer-aided designed/manufactured hollow obturator prosthesis (CAD/CAM prosthesis) after total maxillectomy for malignant maxillary sinus tumor. A retrospective observational study was performed to evaluate the facial profiles and functional recovery of 18 patients with T3-4a N0 M0 maxillary sinus cancer, who were treated by total maxillectomy and simultaneous implantation of a computer-aided designed/manufactured hollow obturator prosthesis (CAD/CAM prosthesis). Follow-ups were performed 1, 3, 6, and 12 months after surgery. Facial measurements, speech intelligibility, and chewing and swallowing functions were examined. Thirteen patients converted to a permanent prosthesis 6 months after surgery. Comparisons were made between patients with and without the CAD/CAM or permanent prosthesis at various times using SPSS13.0 statistical software (SPSS Inc., Chicago, IL, USA). Speech intelligibility, facial depression, and eyeball prolapse results showed improvements with prosthesis use at 1, 3, and 6 months after surgery (p < 0.05). Swallowing function improved from level V to level II-IV with prosthesis use at 1, 3, and 6 months, and reached level I or II with permanent prosthesis use at 12 months after surgery. Simultaneous CAD/CAM prosthesis implantation recovered the facial profile, enhanced the speaking, swallowing, and chewing functions, and improved the quality of life of patients. Tumor recurrence can be detected by direct observation of the postoperative maxillary cavity. Therefore, this operation is recommended for simultaneous excision repair and functional reconstruction after total maxillectomy. This surgical treatment of maxillary sinus cancer is applied rarely in China, but it has a good effect based on our observation. Simultaneous CAD/CAM prosthesis implantation after total maxillectomy can recover the facial profile, enhance the speaking, swallowing, and chewing functions, and improve the quality of life of patients. Tumor recurrence can be detected by direct observation of the postoperative maxillary cavity. This technique avoids the need for dental implants because the bottom part of the prosthesis contains a palatal plate with dentures. © 2014 Wiley Periodicals, Inc.

  9. Narrow- (3.0 mm) Versus Standard-Diameter (4.0 and 4.5 mm) Implants for Splinted Partial Fixed Restoration of Posterior Mandibular and Maxillary Jaws: A 5-Year Retrospective Cohort Study.

    PubMed

    Pieri, Francesco; Forlivesi, Caterina; Caselli, Ernesto; Corinaldesi, Giuseppe

    2017-04-01

    Evidence concerning predictability of narrow-diameter implants (NDIs) (<3.3 mm) to restore partially edentulous posterior maxillary and mandibular areas is limited. The aim of this study is to compare the 5-year outcomes of NDIs (3.0 mm) and standard-diameter implants (SDIs) (4.0 to 4.5 mm) supporting fixed partial dentures (FPDs) in posterior mandibular and maxillary jaws. All patients treated with at least two adjacent NDIs or SDIs according to available bone thickness and with a minimum follow-up of 5 years after placement were invited to undergo a clinical and radiologic examination. Outcome measures were implant and FPD failures, biologic and prosthetic complications, and marginal bone loss. A total of 107 out of 127 patients attended the examination: 49 (113 implants) of the NDI group, and 58 (126 implants) of the SDI group. Two NDIs failed in one patient versus four SDIs in four patients (P = 0.37). One FPD failed in the NDI group versus two FPDs in the SDI group (P >0.99). Nine biologic complications occurred in the NDI group and twelve in the SDI group (P = 0.81). Twelve prosthetic complications occurred in the NDI group and only two in the SDI group (P = 0.001). Peri-implant marginal bone loss at 5 years was 0.95 ± 0.84 mm for the NDI group and 1.2 ± 0.86 mm for the SDI group (P = 0.06). Five-year data indicate that FPD treatment in posterior mandibular and maxillary jaws with NDIs was as reliable as with SDIs, although NDIs showed a higher risk of prosthetic complications.

  10. Finite element analysis of a novel implant distribution to support maxillary overdentures.

    PubMed

    Osman, Reham B; Elkhadem, Amr H; Ma, Sunyoung; Swain, Michael V

    2013-01-01

    To evaluate the biomechanics of a novel implant placement distribution and compare it with that of conventional maxillary overdenture support using three-dimensional finite element analysis (FEA). The application of zirconia implants in the context of this novel design was also evaluated. Detailed FEA models were created to analyze the loading responses of two different distributions of implants to support maxillary overdentures. The two implant distributions were as follows: the conventional design (D1) included four unsplinted implants in the premolar regions, whereas the novel design (D2) included one midpalatal implant, bilateral canine/premolar implants, and one anterior off-center crestal implant. Anatomical models were created with computed tomographic data and static loads were applied axially and obliquely. Von Mises stresses and equivalent strains generated in peri-implant bone and first principal stresses in the implants were calculated, including any denture displacement. Comparable stress and strain values were seen in the peri-implant bone for both designs. A significant decrease in the first principal stresses of D2 implants was observed with oblique loads. The maximum equivalent strain produced in the peri-implant region was mostly within the range for bone augmentation. D2 displayed lower maximum displacement values than D1. Maximum tensile stresses in the zirconia implants for either design were well below their fracture strength. A novel four-implant distribution involving midpalatal and crestal implants may be an alternative to the conventional design used for maxillary overdentures. This is particularly relevant when anatomical considerations prevent the placement of four anterior crestal implants. Zirconia implants may also be a valid option for a selected group of patients or for those requesting metal-free restorations. Prospective clinical studies are required to confirm these in vitro results.

  11. Do traditional techniques produce better conventional complete dentures than simplified techniques? A 10-year follow-up of a randomized clinical trial.

    PubMed

    Kawai, Yasuhiko; Muarakami, Hiroshi; Feine, Jocelyne S

    2018-07-01

    The use of a simplified method (S) of fabricating complete dentures has been shown to be more cost-efficient than the traditional method (T), and there are no negative consequences that detract from the cost savings in the short term. However, it is not clear whether this remains constant over a decade. The objective of this study was to clarify patients' perspectives and determine any differences between the dentures fabricated with these two different techniques after a decade of use. Edentate individuals participated in a randomized controlled clinical trial and completed a 6-month follow-up from 2001 to 2003 (T group n = 50; S group n = 54). For this 10-year follow-up, they were interviewed by telephone. The assessment included whether the denture was still in use or replaced, the condition of the dentures, patient satisfaction and oral health-related quality of life (OHRQoL). Between and within-group differences and the factors that cause deterioration of oral health-related quality of life (OHRQoL) were determined. Among 54 responders (25 T and 29 S), 14T and 21S kept the original dentures. Both groups were similar in ratings of satisfaction and OHRQoL (maxilla T: 80.0 S: 86.0, p = 0.36; mandibular; T: 66.1 S: 72.3, p = 0.48; OHRQoL T: 111.1 S: 108.5, p = 0.46). Irrespective of fabrication method, discomfort, chewing difficulty and esthetics were the factors that deteriorate OHRQoL (adjusted r = 0.76, p < 0.001). The results indicate that the simplified method remains more cost-efficient than the traditional method over a 10-year period. (IRB approval: A09-E71-12 B McGill University, trial registry: ClinicalTrial.org; NCT02289443). Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Masseter muscle fatigue during sustained clenching in subjects with complete dentures, implant-supported prostheses, and natural teeth.

    PubMed

    Jacobs, R; van Steenberghe, D

    1993-03-01

    A sustained submaximal (50%) clenching effort was performed in four patient groups to establish whether implant-supported prosthetic reconstructions influence myoelectrical signal parameters. The first group consisted of patients with natural teeth in both jaws. The other three groups consisted of patients who were edentulous in both jaws: one group had complete dentures; one had an overdenture in the mandible on two implants connected by a bar; and the third had an implant-supported fixed prosthesis in either the maxilla or the mandible. Surface electromyography indicated an increased myoelectrical output level that paralleled a higher bite force level for implant-supported reconstructions compared with complete dentures. Power spectrum analysis revealed a downward shift of the mean power frequency during sustained clenching in all groups except the implant-supported fixed prosthesis. The absence of a spectral shift in the latter group probably reflected a fear of biting too hard and fracturing the prosthesis.

  13. Finite element analysis to compare complete denture and implant-retained overdentures with different attachment systems.

    PubMed

    Barão, Valentim Adelino Ricardo; Assunção, Wirley Gonçalves; Tabata, Lucas Fernando; Delben, Juliana Aparecida; Gomes, Erica Alves; de Sousa, Edson Antonio Capello; Rocha, Eduardo Passos

    2009-07-01

    This finite element analysis compared stress distribution on complete dentures and implant-retained overdentures with different attachment systems. Four models of edentulous mandible were constructed: group A (control), complete denture; group B, overdenture retained by 2 splinted implants with bar-clip system; group C, overdenture retained by 2 unsplinted implants with o'ring system; and group D, overdenture retained by 2 splinted implants with bar-clip and 2 distally placed o'ring system. Evaluation was performed on Ansys software, with 100-N vertical load applied on central incisive teeth. The lowest maximum general stress value (in megapascal) was observed in group A (64.305) followed by groups C (119.006), D (258.650), and B (349.873). The same trend occurred in supporting tissues with the highest stress value for cortical bone. Unsplinted implants associated with the o'ring attachment system showed the lowest maximum stress values among all overdenture groups. Furthermore, o'ring system also improved stress distribution when associated with bar-clip system.

  14. Mini dental implants retaining mandibular overdentures: A dental practice-based retrospective analysis.

    PubMed

    Schwindling, Franz Sebastian; Schwindling, Franz-Peter

    2016-07-01

    The purpose of this study was to assess the survival of mini dental implants (MDI) and to measure prosthetic maintenance needs in a dental practice-based setting. Patients with mandibular removable dentures were provided with MDI to improve denture retention. Complications and maintenance were analyzed by use of patient records and evaluated with Kaplan-Meier curves and the log rank test at a significance level of 0.05. Ninety-nine MDI were placed in 25 patients (mean age: 72 years). Two MDI fractured during placement and eight implants failed during the first weeks. No more implants were lost for up to seven years, resulting in 92% survival. Implant survival differed significantly depending on whether the maxilla was provided with complete dentures (94.9%) or with partial dentures (81%). All prostheses were in use at the time of data extraction. Denture base fractures were observed in six cases, an incidence of fractures of 24%. Some minor intervention was necessary: one resin tooth fractured, retention rings were changed in five cases, and repeated relining was required for 16% of the dentures. After mid-term observation, survival of MDI was good. However, the incidence of denture base fractures and of minor prosthetic complications should not be under-estimated. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Single dental implant retained mandibular complete dentures – influence of the loading protocol: study protocol for a randomized controlled trial

    PubMed Central

    2014-01-01

    Background Over the years, there has been a strong consensus in dentistry that at least two implants are required to retain a complete mandibular denture. It has been shown in several clinical trials that one single median implant can retain a mandibular overdenture sufficiently well for up to 5 years without implant failures, when delayed loading was used. However, other trials have reported conflicting results with in part considerable failure rates when immediate loading was applied. Therefore it is the purpose of the current randomized clinical trial to test the hypothesis that immediate loading of a single mandibular midline implant with an overdenture will result in a comparable clinical outcome as using the standard protocol of delayed loading. Methods/design This prospective nine-center randomized controlled clinical trial is still ongoing. The final patient will complete the trial in 2016. In total, 180 edentulous patients between 60 and 89 years with sufficient complete dentures will receive one median implant in the edentulous mandible, which will retain the existing complete denture using a ball attachment. Loading of the median implant is either immediately after implant placement (experimental group) or delayed by 3 months of submerged healing at second-stage surgery (control group). Follow-up of patients will be performed for 24 months after implant loading. The primary outcome measure is non-inferiority of implant success rate of the experimental group compared to the control group. The secondary outcome measures encompass clinical, technical and subjective variables. The study was funded by the Deutsche Forschungsgemeinschaft (German research foundation, KE 477/8-1). Discussion This multi-center clinical trial will give information on the ability of a single median implant to retain a complete mandibular denture when immediately loaded. If viable, this treatment option will strongly improve everyday dental practice. Trial registration The trial has been registered at Deutsches Register Klinischer Studien (German register of clinical trials) under DRKS-ID: DRKS00003730 since 23 August 2012. (http://www.germanctr.de). PMID:24884848

  16. Various Techniques to Increase Keratinized Tissue for Implant Supported Overdentures: Retrospective Case Series

    PubMed Central

    Cayarga, Rodrigo; Suzuki, Takanori; Kaufman, Zev

    2015-01-01

    Purpose. The purpose of this retrospective case series is to describe and compare different surgical techniques that can be utilized to augment the keratinized soft tissue around implant-supported overdentures. Materials and Methods. The data set was extracted as deidentified information from the routine treatment of patients at the Ashman Department of Periodontology and Implant Dentistry at New York University College of Dentistry. Eight edentulous patients were selected to be included in this study. Patients were treated for lack of keratinized tissue prior to implant placement, during the second stage surgery, and after delivery of the final prosthesis. Results. All 8 patients in this study were wearing a complete maxillary and/or mandibular denture for at least a year before the time of the surgery. One of the following surgical techniques was utilized to increase the amount of keratinized tissue: apically positioned flap (APF), pedicle graft (PG), connective tissue graft (CTG), or free gingival graft (FGG). Conclusions. The amount of keratinized tissue should be taken into consideration when planning for implant-supported overdentures. The apical repositioning flap is an effective approach to increase the width of keratinized tissue prior to the implant placement. PMID:26124833

  17. Comparative evaluation of border molding using two different techniques in maxillary edentulous arches: A clinical study

    PubMed Central

    Qanungo, Anchal; Aras, Meena Ajay; Chitre, Vidya; Coutinho, Ivy; Rajagopal, Praveen; Mysore, Ashwin

    2016-01-01

    Purpose: The aim of this in vivo study was to compare the single-step border molding technique using injectable heavy viscosity addition silicone with sectional border molding technique using low fusing impression compound by evaluating the retention of heat cure trial denture bases. Materials and Methods: Ten completely edentulous patients in need of prostheses were included in this study. Two border molding techniques, single-step (Group 1) and sectional (Group 2), were compared for retention. Both border molding techniques were performed in each patient. In both techniques, definitive wash impression was made with light viscosity addition silicone. The final results were analyzed using paired t-test to determine whether significant differences existed between the groups. Results: The t-value (3.031) infers that there was a significant difference between Group 1 and Group 2 (P = 0.014). The retention obtained in Group 2 (mean = 9.05 kgf) was significantly higher than that of Group 1 (mean = 8.26 kgf). Conclusion: Sectional border molding technique proved to be more retentive as compared to single-step border molding although clinically the retention appeared comparable. PMID:27746597

  18. Hader bar and clip attachment retained mandibular complete denture

    PubMed Central

    Singh, Kunwarjeet; Gupta, Nidhi; Kapoor, Vikram; Gupta, Ridhimaa

    2013-01-01

    Bar and clip attachments significantly improve the level of satisfaction of denture-wearing patients by enhancing the retention and stability of the prosthesis. These attachments have been most commonly used for connecting the prosthesis to implants, but they can be effectively used to retain tooth-supported prosthesis as well. The primary functions of bar attachments are splinting the abutments together, even distribution of forces to the abutments and supporting areas, guiding the prosthesis into place, improving the retention, stability, support and comfort of the patient. The primary requirement for the use of bar attachments is the availability of sufficient vertical and buccolingual space for the proper placement of the bar, sleeves, teeth arrangement and sufficient thickness of acrylic denture base to minimise incidence of denture fracture in the area of bar assembly. PMID:24145505

  19. Hader bar and clip attachment retained mandibular complete denture.

    PubMed

    Singh, Kunwarjeet; Gupta, Nidhi; Kapoor, Vikram; Gupta, Ridhimaa

    2013-10-21

    Bar and clip attachments significantly improve the level of satisfaction of denture-wearing patients by enhancing the retention and stability of the prosthesis. These attachments have been most commonly used for connecting the prosthesis to implants, but they can be effectively used to retain tooth-supported prosthesis as well. The primary functions of bar attachments are splinting the abutments together, even distribution of forces to the abutments and supporting areas, guiding the prosthesis into place, improving the retention, stability, support and comfort of the patient. The primary requirement for the use of bar attachments is the availability of sufficient vertical and buccolingual space for the proper placement of the bar, sleeves, teeth arrangement and sufficient thickness of acrylic denture base to minimise incidence of denture fracture in the area of bar assembly.

  20. Reconstruction of an Extensive Midfacial Defect Using Additive Manufacturing Techniques.

    PubMed

    Fernandes, Nelson; van den Heever, Jacobus; Hoogendijk, Christiaan; Botha, Sarel; Booysen, Gerrie; Els, Johan

    2016-10-01

    Malignant peripheral nerve sheath tumors are extremely rare tumors arising in peripheral nerves. Only 17 cases involving the trigeminal nerve have ever been reported. These tumors have a very poor prognosis and very high rates of recurrence and metastases. Their recommended treatment involves complete tumor resection followed by radiation. This can be problematic in the head and neck region. We present a clinical case involving a 33-year-old female patient presenting with a slow-growing, exophytic mass of the anterior maxilla. Incisional biopsy and subsequent histological examination revealed a diagnosis of a malignant peripheral nerve sheath tumor. Surgical resection involved a complete maxillectomy, rhinectomy, and resection of the upper lip and aspects of the left and right cheeks. Reconstruction of the subsequent defect incorporated the placement of four zygomatic oncology implants to aid in retention of a facial prosthesis. These implants, however, were subsequently lost; and an anatomical model of the hard tissues was manufactured via 3D printing. This model was used to design and manufacture a titanium frame (customized implant) for the patient. The frame was then fixated and secured intraoperatively with 21 cortical screws. A maxillary denture and silicone facial prosthesis were also made to fit onto this frame. This is the first known case where additive manufacturing, via the use of rapid prototyping and 3D printing, was employed to manufacture a facial prosthesis. © 2016 by the American College of Prosthodontists.

  1. A List of U.S. Government Medical and Dental 8mm Films for Sale by the National Audiovisual Center.

    ERIC Educational Resources Information Center

    National Archives and Records Service (GSA), Washington, DC. National Audiovisual Center.

    Over 200 8mm films for the use of doctors, dentists, and others in related fields are listed. Dental films are categorized into the following topics: anatomy -- head and neck; complete dentures; diagnosis; endodontics; fixed partial dentures; occlusion; operative dentistry; oral hygiene; patient education; periodontics; radiology; removable…

  2. Nutritional status and oral status of the elderly with dementia: a 2-year study.

    PubMed

    Sadamori, Shinsuke; Hayashi, Syouji; Fujihara, Isao; Abekura, Hitoshi; Hamada, Taizo; Akagawa, Yasumasa

    2012-06-01

    To determine the relationship between denture wearing and nutritional status in the elderly with dementia. There could be a correlation between nutrition, oral health, dietary habits, patients' satisfaction, and their socio-economic status in the elderly, and the relationship between compromised oral status and nutritional status in the elderly with dementia. A 2-year follow-up study of 63 elderly Japanese women with and without dentures from a nursing home was undertaken to investigate their oral, physical and mental, and nutritional status. Each item for 2006 and 2008 in this study showed no significant difference between 2006 and 2008, except the calories/day. The elderly with dementia without complete dentures during the 2 years of the study only significantly decreased the mean of the calories/day. The calories/day of the elderly with dementia without dentures decreased after 2 years. Denture wearing for the elderly with dementia could be necessary to maintain a satisfactory intake of calories. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  3. Overdenture restoration in a growing patient with hypohidrotic ectodermal dysplasia: a clinical report.

    PubMed

    Pae, Ahran; Kim, Kyu; Kim, Hyeong-Seob; Kwon, Kung-Rock

    2011-03-01

    Ectodermal dysplasia is a hereditary disorder of ectodermal origin. A 12-year-old boy was referred for management of the oral manifestations of his ectodermal dysplasia. An overdenture retained by natural teeth for the maxilla and a double-crown-retained denture for the mandible were made. Double-crown-retained dentures may be modified into complete dentures if the abutment teeth are lost. The patient was instructed to maintain oral hygiene and return periodically for follow-up visits. This report describes a potential routine approach to restoring the appearance, function, and psyche of a growing boy with ectodermal dysplasia.

  4. Biometric Denture Space- Concept of Neutral Zone Revisited Using A Hydrocolloid Impression Material

    PubMed Central

    Umamaheswaran, Aruna; Nayar, Sanjna

    2015-01-01

    Though the concept of neutral zone in making complete denture and its significance are well known, the material of choice has always been experimented to achieve better results. Recording of neutral zone using irreversible hydrocolloid (Alginate) as a material of choice would make the way of recording the neutral zone easier, as well as comfortable for the patient, when compared with other materials used for the purpose. This article describes the method of recording the biometric denture space (neutral zone) using hydrocolloid impression material which is most commonly used in everyday dental practice. PMID:26673250

  5. Influence of artificial aging on the load-bearing capability of straight or angulated zirconia abutments in implant/tooth-supported fixed partial dentures.

    PubMed

    Nothdurft, Frank P; Doppler, Klaus E; Erdelt, Kurt J; Knauber, Andreas W; Pospiech, Peter R

    2010-01-01

    The aim of the study was to evaluate the influence of artificial aging on the fracture behavior of straight and angulated zirconia implant abutments used in ZirDesign (Astra Tech) implant/tooth-supported fixed partial dentures (FPDs) in the maxilla. Four different test groups (n = 8) representing anterior implant/tooth-supported FPDs were prepared. Groups 1 and 2 simulated a clinical situation with an ideal implant position (maxillary left central incisor) from a prosthetic point of view, which allowed for the use of a straight, prefabricated zirconia abutment. Groups 3 and 4 simulated a situation with a compromised implant position that required an angulated (20-degree) abutment. OsseoSpeed implants (4.5 3 13 mm, Astra Tech) as well as metal tooth analogs (maxillary right lateral incisor) with simulated periodontal mobility were mounted in polymethyl methacrylate. The FPDs (chromium-cobalt alloy) were cemented with glass ionomer. Groups 2 and 4 were thermomechanically loaded and subjected to static loading until failure. Statistical analysis of force data at the fracture site was performed using nonparametric tests. All samples survived thermomechanical loading. Artificial aging did not lead to a significant decrease in load-bearing capacity in either the straight abutments or the angulated abutments. The restorations that used angulated abutments exhibited higher fracture loads than the restorations with straight abutments (group 1: 209.13 ± 39.11 N; group 2: 233.63 ± 30.68 N; group 3: 324.62 ± 108.07 N; group 4: 361.75 ± 73.82 N). This difference in load-bearing performance was statistically significant, both with and without artificial aging. All abutment fractures occurred below the implant shoulder. Compensation for angulated implant positions with an angulated zirconia abutment is possible without reducing the load-bearing capacity of implant/tooth-supported anterior FPDs.

  6. Does a mandibular overdenture improve nutrient intake and markers of nutritional status better than conventional complete denture? A systematic review and meta-analysis.

    PubMed

    Yamazaki, Toru; Martiniuk, Alexandra Lc; Irie, Koichiro; Sokejima, Shigeru; Lee, Crystal Man Ying

    2016-08-03

    The need for denture treatment in public health will increase as the population ages. However, the impact of dentures on nutrition, particularly overdenture treatment, remains unclear although the physical and psychological effects are known. We investigated whether treatment with a mandibular implant supported overdenture improves nutrient intake and markers of nutritional status better than a conventional complete denture in edentulous patients. Systematic review and meta-analysis. Medline, EMBASE and the Cochrane Central Register of Controlled Trials were searched for eligible studies published up to April 2016. We included studies which compared the treatment effect of an overdenture to conventional denture on nutrition, in which primary outcomes included changes in intake of macronutrients and/or micronutrients and/or indicators of nutritional status. Two reviewers independently evaluated eligible studies and assessed the risk of bias. We used a fixed effects model to estimate the weighted mean difference (WMD) and 95% CI for change in body mass index (BMI), albumin and serum vitamin B12 between overdenture and conventional denture 6 months after treatment. Of 108 eligible studies, 8 studies involving 901 participants were included in the narrative appraisal. Four studies reported changes in markers of nutritional status and nutrient intake after treatment with a prosthetic, regardless of type. In a meta-analysis of 322 participants aged 65 years or older from three studies, pooled analysis suggested no significant difference in change in BMI between an overdenture and conventional denture 6 months after treatment (WMD=-0.18 kg/m(2) (95% CI -0.52 to 0.16)), and no significant difference in change in albumin or vitamin B12 between the two treatments. The modifying effect of overdenture treatment on nutritional status might be limited. Further studies are needed to evaluate the effectiveness and efficacy of denture treatments. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. Evaluation of three indices for biofilm accumulation on complete dentures.

    PubMed

    Paranhos, Helena de Freitas Oliveira; Lovato da Silva, Claudia Helena; de Souza, Raphael Freitas; Pontes, Karina Matthes de Freitas

    2010-03-01

    The objective of this study was to evaluate the accuracy and reproducibility of three complete denture biofilm indices (Prosthesis Hygiene Index; Jeganathan et al. Index; Budtz-Jørgensen Index) by means of a computerised comparison method. Clinical studies into denture hygiene have employed a large number of biofilm indices among their outcome variables. However, the knowledge about the validity of these indices is still scarce. Sixty-two complete denture wearers were selected. The internal surfaces of the upper complete dentures were stained (5% erythrosine) and photographed. The slides were projected on paper, and the biofilm indices were applied over the photos by means of a scoring method. For the computerised method, the areas (total and biofilm-covered) were measured by dedicated software (Image Tool). In addition, to compare the results of the computerised method and Prosthetic Hygiene Index, a new scoring scale (including four and five graded) was introduced. For the Jeganathan et al. and Budtz-Jørgensen indices, the original scales were used. Values for each index were compared with the computerised method by the Friedman test. Their reproducibility was measured by means of weighed kappa. Significance for both tests was set at 0.05. The indices tested provided similar mean measures but they tended to overestimate biofilm coverage when compared with the computerised method (p < 0.001). Agreement between the Prosthesis Hygiene Index and the computerised method was not significant, regardless of the scale used. Jeghanathan et al. Index showed weak agreement, and consistent results were found for Budtz-Jorgensen Index (kappa = 0.19 and 0.39 respectively). Assessment of accuracy for the biofilm indices showed instrument bias that was similar among the tested methods. Weak inter-instrument reproducibility was found for the indices, except for the Budtz-Jørgensen Index. This should be the method of choice for clinical studies when more sophisticated approaches are not possible.

  8. The effect of prosthetic rehabilitation and simple dietary counseling on food intake and oral health related quality of life among the edentulous individuals: A randomized controlled trial.

    PubMed

    Amagai, Noriko; Komagamine, Yuriko; Kanazawa, Manabu; Iwaki, Maiko; Jo, Ayami; Suzuki, Hiroyuki; Minakuchi, Shunsuke

    2017-10-01

    To investigate the combined effect of complete denture renewal and simple dietary advice. A randomized controlled trial was performed with edentulous patients who required new complete dentures. All participants received complete denture treatment. In addition, the intervention group received dietary advice in a pamphlet form, while the control group received advice pertaining to the care and maintenance of the dentures. The advice was given by dentists for each group. The participants' food intake was assessed at baseline and 3 months after intervention using a diet history questionnaire and an oral health related quality of life assessment measured using the Japanese version of the Oral Health Impact Profile for edentulous people (OHIP-EDENT-J). Among 70 participants who were randomized, 62 participants finished all parts of this trial. At baseline, there was no significant difference in the food intake between the two groups. At the 3-month assessment, the intervention group showed significantly greater intake of chicken (P=0.013), fish with bones (P=0.012), and carrots and pumpkins (P=0.025) compared to the control group. However, at baseline and at the 3-month assessment, there was no significant difference in the OHIP-EDENT-J scores between the groups, but the OHIP-EDENT-J scores significantly improved for both groups at the 3-month assessment. There were more significant improved dimensions of OHIP-EDENT-J in the intervention group than in the control group at the 3-month assessment. Simple dietary advice combined with complete denture treatment could improve food intake of edentulous patients. The present study suggests that brief dietary advice provided by dentists can improve food intake of edentulous elderly. This simply diet advice is much easier compared to customized forms, might enable normal dentists provide patients it. The result of this study broadens possibility of nutritional counseling in daily clinical practice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Prosthodontics an “arsenal” in forensic dentistry

    PubMed Central

    Bathala, Lakshmana Rao; Rachuri, Narendra Kumar; Rayapati, Srinivas Rao; Kondaka, Sudheer

    2016-01-01

    After major disasters such as earthquakes, fires, floods, tsunami, bomb blasts or terrorist attacks, accurate, and early identification of the dead and injured becomes an utmost importance. Restorations, cariesteeth, missingteeth and/or prostheses are most useful aids for the dental identification. At times, only identifiable remains are a victim's partial or complete dentures. The central principle of dental identification is that postmortem dental remains can be compared with antemortem dental records which include, studycasts, radiographs, etc., to confirm the identity of the victims. Marking/labeling dentures have been considered an important aid in forensic dentistry. Other than finger printing, when compared with all the methods, the marking/labeling of dentures is an accurate and rapid method to identify the unknown victims. There are no standardized methods to follow, but dental practitioners needs to maintain some dental records of their patients. This may include documentation of the “marking of dentures.” The preparedness is the key to success in mass disaster identification. The aim of this review article is to discuss the methods of denture identification, advantages of denture labeling for the rapid identification during major disasters/accidents and the importance of maintaining the patient records. PMID:28123274

  10. The needs of denture-brushing in geriatrics: clinical aspects and perspectives.

    PubMed

    Berteretche, Marie-Violaine; Mastari, Fatima; Nicolas, Emmanuel; Hüe, Olivier

    2012-06-01

    Oral and denture hygiene are often defective in particular with dependent persons such as geriatric subjects. The reasons are the lack of hygiene education of the subjects or those caring for them. Consequently, oral hygiene is often neglected, resulting in poor oral health and an increase in the presence of local or general infections. This paper is a report of brushing effectiveness on microbial biofilm deposits on dentures of subjects participating in a specific oral hygiene programme. Thirty-nine dentures of 30 subjects were assessed for 2 weeks following an educational brushing programme. Microbial biofilm was recovered using fluoresceine and then scanned and quantified by 'Mesurim' software three times: before study, after 1 and 2 weeks. The repeated measurement procedures showed a decrease in the percentage of biofilm present (F = 15, p < 0.001) whatever the type of denture (partial or complete) and for all biomaterials. Regular denture-brushing can improve local hygiene. Consequently, decreasing the biofilm surface can reduce the prevalence of oral pathogens, thereby contributing to the general prevention of the risks of infections such as pneumotisis. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  11. Materials for interocclusal records and their ability to reproduce a 3-dimensional jaw relationship.

    PubMed

    Ockert-Eriksson, G; Eriksson, A; Lockowandt, P; Eriksson, O

    2000-01-01

    The purpose of this study was to determine if accuracy and dimensional stability of vinyl polysiloxanes and irreversible hydrocolloids stabilized by a tray used for fixed prosthodontics, removable partial, and complete denture cases are comparable to those of waxes and record rims and if storage time (24 hours or 6 days) affects dimensional stability of the tested materials. Two waxes, two record rims, three vinyl polysiloxanes, and one irreversible hydrocolloid (alginate) were examined. Three pairs of master casts with measuring steel rods were mounted on an articulator (initial position). Five records were made of each material, and the upper cast was remounted after 24 hours or 6 days so that deviations from the initial position could be measured. Vinyl polysiloxanes reinforced by a stabilization tray were the most accurate materials able to reproduce a settled interocclusal position. Mounting casts (fixed prosthodontics cases) without records gave accuracy similar to wax records. Record rims used for removable partial and complete denture cases produced lesser accuracy than vinyl polysiloxanes and irreversible hydrocolloid stabilized by a tray. Accuracy was not significantly affected by storage time. The results show that accuracy of vinyl polysiloxanes and irreversible hydrocolloids reinforced by a tray is superior to that of record rims with regard to the complete denture case and is among the most accurate with regard to the removable partial denture case. For fixed prosthodontics, however, reinforcement is unnecessary.

  12. Comparison of three-implant-supported fixed dentures and two-implant-retained overdentures in the edentulous mandible: a pilot study of treatment efficacy and patient satisfaction.

    PubMed

    De Kok, Ingeborg J; Chang, Kuang-Han; Lu, Tsui-Shan; Cooper, Lyndon F

    2011-01-01

    The mandibular two-implant overdenture has been shown to be a highly successful treatment. However, overdenture patients who desire a fixed prosthesis may not be satisfied with a removable overdenture. This prospective study sought to compare prosthetic outcomes, patient satisfaction, and survival rates of implants between two-implant-supported overdentures (IODs) and three-implant-supported fixed dentures (ISFDs). Twenty completely edentulous patients were randomly and equally assigned to two groups. New conventional complete dentures were made, and the mandibular denture was used as a surgical guide during implant placement. Implants were placed in one stage, followed by a mandibular denture soft reline (provisional loading). Ball attachments were inserted at 8 weeks, and ISFDs were delivered at 16 weeks. IODs were connected to the attachments at 8 weeks, using each patients's existing denture. The definitive ISFDs were fabricated using computer-aided design/computer-assisted manufacture milled titanium frameworks and acrylic resin base and teeth. Patient satisfaction and panoramic radiographs were investigated at 6 and 12 months. Both treatments had significant and positive effects on patient satisfaction and quality of life. None of the 50 implants placed had failed at 12 months of follow-up; therefore, the implant survival rate was 100%. Prosthetic complications were generally rare and easily manageable. Both the treatment modalities-the ISFD supported by three implants and the IOD supported by two implants-significantly and similarly improved patient satisfaction and oral health-related quality of life, and prosthetic complications were relatively rare for both treatments. Three implants can be used to support a mandibular fixed prosthesis; however, a longer observation period is needed to validate this treatment modality.

  13. [Overdenture supported by natural teeth: analysis of clinical advantages].

    PubMed

    Scotti, R; Melilli, D; Pizzo, G

    2003-05-01

    Hybrid prosthesis supported by natural teeth (overdenture) is widely used in clinical practice and should be executed whenever the clinical conditions suggest it. Through a critical review of the literature, the anatomical, functional, psychological and clinical advantages are emphasized. Among the first ones, the prophylaxis of residual anatomical components, due to the limitation of bone resorption, and the preservation of sensorial proprioception are relevant. Important advantages are also represented by a better crown-root ratio of residual teeth supporting overdenture, with the consequent improvement of the longitudinal prognosis of such teeth. The greater retention and stability of overdenture in comparison with complete denture greatly improve the masticatory efficacy. The psychological advantages resulting from the dental anchorage, which allows the patient to be more confident in social life, are also relevant. Finally, when the dental support is lost, converting overdenture into complete denture is simple and quick, and makes easier the longitudinal clinical maintenance of the denture.

  14. Maxillary distraction in patients with cleft deformity using a rigid external distraction device: a pilot study on the distraction ratio of the maxilla to the device.

    PubMed

    Harada, Kiyoshi; Sato, Masaru; Omura, Ken

    2004-01-01

    We examined the ratio between actual maxillary distraction and the distraction of the rigid external distraction device (Rigid external distraction (RED) system) used for maxillary distraction in patients with a cleft deformity. Twelve patients were examined. The amount of maxillary advancement was measured on lateral cephalograms and divided by the activation amount on the RED system. The value obtained was represented as the distraction ratio of the maxilla to the system. The mean ratio in 10 patients with complete cleft lip, palate, and alveolus (complete cleft) was 0.24. However, the ratios in two patients with cleft lip and alveolus or soft cleft palate (incomplete cleft) were considerably higher than the mean ratios in patients with complete cleft. When the maxilla is distracted in patients with complete cleft using the RED system, the amount of activation on the system needs to be about four times the amount of planned maxillary distraction. However, the distraction ratio may be affected by the type of cleft.

  15. Antifungal Effect of Henna against Candida albicans Adhered to Acrylic Resin as a Possible Method for Prevention of Denture Stomatitis

    PubMed Central

    Nawasrah, Amal; AlNimr, Amani; Ali, Aiman A.

    2016-01-01

    Denture stomatitis is a very common disease affecting the oral mucosa of denture wearers. The aim of this study was to measure the antifungal effect of henna against Candida albicans adhered to acrylic resin as a possible method for prevention of denture stomatitis. One-hundred-eighty acrylic plates were prepared of heat-cured acrylic denture resin. The specimens were divided into six groups of 30 samples each. The first group was only polymer and monomer following the conventional manufacturer instruction for processing complete dentures. The other five groups were processed by adding different concentration of Yamani henna powder (Harazi) to the polymer in a concentration of henna: polymer 1%, 2.5%, 5%, 7.5% and 10%, respectively. Samples were incubated in artificial saliva rich with Candida albicans at 37 °C, and the effect of henna on Candida albicans was evaluated in two different methods: semi-quantitative slide count and a culture-based quantitative assay (quantitative). Variation in the number of live Candida was observed with the increase in the concentration of Yamani henna powder. It was observed that the variation in live Candida, between control group and group B (concentration of Yamani henna powder was 1%), was statistically significant with a p-value of 0.0001. Similarly, variations in live Candida were significant, when the concentration of powder was 7.5% or 10% in contrast with control group and p-values were 0.0001 and 0.001 respectively. Adding henna to acrylic resin denture could be effective in controlling Candida albicans proliferation on the denture surface; however, its effects on the physical properties of acrylic resin denture need further studies. PMID:27223294

  16. The impact of the National Denture Service on oral health-related quality of life among poor elders.

    PubMed

    Ha, J E; Heo, Y J; Jin, B H; Paik, D I; Bae, K H

    2012-08-01

    The objective of this study was to assess the effects of the Korean National Denture Service (NDS) for poor elderly people requiring dentures on oral health-related quality of life (OHRQOL). Data from follow-up studies were collected from 439 subjects at eight public health centres who answered every question of a questionnaire, and the OHRQOL was measured at the baseline and at 3-month follow-up after receiving the NDS according to the type of denture provision. The multivariate linear mixed model with a public health centre as a random effect for the score change of Oral Health Impact Profile (OHIP)-14K was carried out to confirm the factors related to the improvement in OHRQOL. The mean OHIP-14K was 28.60 at the baseline time points, and there was a decrease in the OHIP-14 scores to 21.14 ± 12.52 at the 3-month follow-up of the removable partial denture beneficiaries. The changes in OHIP-14K among complete denture beneficiaries were 21.53 ± 12.01 for previously dentate subjects and 22.54 ± 11.12 for edentate subjects. The multivariate linear mixed model of dentate subjects demonstrated that the improvement in the OHRQOL was associated with the number of remaining teeth, satisfaction with denture and self-reported oral health status after 3 months. In the case of the edentate model, satisfaction with denture was the only factor related to the improvement in OHRQOL. This study revealed considerable improvement in OHRQOL among poor elderly people after NDS. Satisfaction with provision of dentures was associated with improvement in the OHRQOL. © 2012 Blackwell Publishing Ltd.

  17. Wispy Prosthesis: A Novel Method in Denture Weight Reduction

    PubMed Central

    Anne, Gopinadh; Budeti, Sreedevi; Anche, Sampath Kumar; Zakkula, Srujana; Atla, Jyothi; Jyothula, Ravi Rakesh Dev; Peddinti, Vijaya Kumar

    2016-01-01

    Introduction Stability and retention of the denture becomes at stake with the increase in weight of the denture prosthesis. As a consequence, different materials and methods have been introduced to overcome these issues but denture weight reduction still remains to be a cumbersome and strenuous procedure. Aim To introduce a novel technique for the fabrication of denture prosthesis where in the weight of the denture will not affect the retention and stability of the denture. Materials and Methods Four groups with a sample size of 10 each, were included where in one group was control and other three were study groups. The control group samples were made completely solid and the study group samples were packed with materials like bean balls, cellulose balls and polyacrylic fibers. The weight of all the samples of each study group was measured and compared with the control group. The observations were analyzed statistically by paired t-test. Results It was observed that the bean balls group produced a weight reduction of 31.3%, cellulose balls group 27.4% and polyacrylic fibers group 24.5% when compared to that of the control group. Conclusion This novel technique will eliminate the problems that were associated in creating hollowness and at the same time will reduce the weight of the prosthesis and among all the study groups, bean balls group were found to reduce maximum weight of the prosthesis. PMID:27190947

  18. Wispy Prosthesis: A Novel Method in Denture Weight Reduction.

    PubMed

    Anne, Gopinadh; Budeti, Sreedevi; Anche, Sampath Kumar; Zakkula, Srujana; Atla, Jyothi; Jyothula, Ravi Rakesh Dev; Appana, Krishna Chaitanya; Peddinti, Vijaya Kumar

    2016-04-01

    Stability and retention of the denture becomes at stake with the increase in weight of the denture prosthesis. As a consequence, different materials and methods have been introduced to overcome these issues but denture weight reduction still remains to be a cumbersome and strenuous procedure. To introduce a novel technique for the fabrication of denture prosthesis where in the weight of the denture will not affect the retention and stability of the denture. Four groups with a sample size of 10 each, were included where in one group was control and other three were study groups. The control group samples were made completely solid and the study group samples were packed with materials like bean balls, cellulose balls and polyacrylic fibers. The weight of all the samples of each study group was measured and compared with the control group. The observations were analyzed statistically by paired t-test. It was observed that the bean balls group produced a weight reduction of 31.3%, cellulose balls group 27.4% and polyacrylic fibers group 24.5% when compared to that of the control group. This novel technique will eliminate the problems that were associated in creating hollowness and at the same time will reduce the weight of the prosthesis and among all the study groups, bean balls group were found to reduce maximum weight of the prosthesis.

  19. Maxillary advancement using distraction osteogenesis with intraoral device.

    PubMed

    Takigawa, Yoko; Uematsu, Setsuko; Takada, Kenji

    2010-11-01

    This article describes the surgical orthodontic treatment of maxillary hypoplasia in a patient with cleft lip and palate using maxillary distraction osteogenesis with internal maxillary distractors. Maxillary advancement was performed to correct the retrusive maxillary facial profile and Class III malocclusion. Rotational movement of the distraction segment was made to correct the upper dental midline. Although maxillary advancement was insufficient because of unexpected breakage of the intraoral distractor after completion of the distraction, skeletal traction with a face mask compensated for the shortage. Successful esthetic improvement and posttreatment occlusal stability were achieved with no discernible relapse after 2 years of retention.

  20. Palatal versus vestibular piezoelectric window osteotomy for maxillary sinus elevation: a comparative clinical study of two surgical techniques.

    PubMed

    Stübinger, Stefan; Saldamli, Belma; Seitz, Oliver; Sader, Robert; Landes, Constantin A

    2009-05-01

    The goal of this study was to compare the surgical advantages and disadvantages of a new palatal access osteotomy for sinus elevation with a conventional lateral approach. In 32 patients, either a palatal (n = 16) or a lateral (n = 16) osteotomy to the maxillary sinus was performed under local anesthesia. The palatal access included a circular paramarginal incision and elevation of a palatal mucosal flap based on a median pedicle. The lateral access was performed by vestibular standard incision and development of a mucoperiosteal flap with a vestibular and superior basis. For all osteotomies a piezoelectric device was used. The sinus cavity was augmented with synthetic nanostructured hydroxyapatite graft material. Intraoperative complications during both procedures were minimal and wound healing was uneventful. Membrane perforation occurred in 19% of the palatal group and in 19% of the lateral group. Soft tissue management of the palatal technique was superior to that of the lateral approach, because the vestibular anatomy was not altered and consequently no disharmonious soft tissue scarring and no postoperative swelling occurred. The palatal approach permitted higher postoperative comfort, especially for edentulous patients, because full dentures could be incorporated directly after surgery with almost perfect fit.

  1. A Different Pontic Design for Fiber-Reinforced Composite Bridgeworks: A Clinical Report

    PubMed Central

    Kumbuloḡlu, Ovul; Özdemir, Niler; Aksoy, Gökhan; User, Atilla

    2007-01-01

    Objectives This clinical report describes a relatively simple but esthetic, non-invasive and functional prosthodontic treatment option for a patient with missing tooth. Methods A patient with a missing maxillary left canine was non-invasively treated with a fiber reinforced composite (FRC) bridgework with an all ceramic (Empress II, Ivoclar Vivadent, Schaan, Liech-tenstein) pontic design, using laboratory technique. Results The restoration has served the patient for 2 year, seemingly without discomfort, and it has not required any maintenance. The patient has kept up with his oral hygiene. Conclusions Although additional clinical experience is necessary, fiber-reinforced composite materials can be used in combination with a lithium disilicate ceramic material in fixed partial dentures. PMID:19212498

  2. Complete Overlay Denture for Pedodontic Patient with Severe Dentinogenesis Imperfecta.

    PubMed

    Syriac, Gibi; Joseph, Elizabeth; Rupesh, Suresh; Mathew, Josey

    2017-01-01

    Dentinogenesis imperfecta (DI) is a hereditary condition that may affect both primary and permanent dentition and is characterized by abnormal dentin formation. The teeth may be discolored with chipping of enamel and, in untreated cases, the entire dentition may wear off to the gingiva. This may lead to the formation of abscesses, tooth mobility, and early loss of teeth. In the Indian population, DI is found to have an incidence of 0.09%. Treatment of DI should aim to remove infection, if any, from the oral cavity; restore form, function, and esthetics; and protect posterior teeth from wear for maintaining the occlusal vertical dimension. Treatment strategies should be selected based on the presenting complaint of the patient, patient's age, and severity of the problem. This case report presents the management of severe DI with tooth worn off until gingival level in a very young patient using complete overlay denture, which has not been reported earlier. How to cite this article: Syriac G, Joseph E, Rupesh S, Mathew J. Complete Overlay Denture for Pedodontic Patient with Severe Dentinogenesis Imperfecta. Int J Clin Pediatr Dent 2017;10(4):394-398.

  3. Color Stability of Heat-cure Acrylic Resin Subjected to Simulated Short-term Immersion in Fast-acting Denture Cleansers.

    PubMed

    Lohitha, K; Prakash, M; Gopinadh, A; Sai Sankar, A J; Sandeep, C H; Sreedevi, B

    2016-01-01

    Regular usage of denture cleansers is recommended in complete denture wearers for effective plaque control, and these cleansers alter the physical properties of acrylic resin over a period of time. Thus, an in vitro study was carried out to assess the effect of denture cleansers on the color stability of heat-cure denture base resin. The aim of the present study was to evaluate the effect of commercially available fast-acting denture cleansers on the color stability of heat-cure denture base resin at different time intervals. Thirty-six heat-cure acrylic resin (Ivoclar Triplex Hot-V) specimens are randomly allocated into four groups - Group A (distilled water as control); Group B (polident - 3 min); Group C (fixodent scope plus); and Group D (stain away plus) comprising of nine samples each. After recording the baseline values, the specimens were immersed in their respective cleansing solutions for a prescribed time interval. This procedure was repeated daily, and the color change (ΔE) was evaluated after 90 and 180 days interval using a colorimeter in a standard "Commission International de l'Eclairage" color system. Paired t -test and Dunnett's T3 test. All the groups exhibited a variable color change (ΔE) for an immersion period of 90 days. However, significant color differences ( P = 0.001) were noticed among the test groups after 180 days. The color change of denture base resin was greater for Group D followed by Groups B, C, and A respectively after 180 days of immersion. The ΔE values of all test groups increased with time.

  4. Chewing efficiency and maximum bite force with different attachment systems of implant overdentures: a crossover study.

    PubMed

    Elsyad, Moustafa Abdou; Khairallah, Ahmed Samir

    2017-06-01

    This crossover study aimed to evaluate and compare chewing efficiency and maximum bite force (MBF) with resilient telescopic and bar attachment systems of implant overdentures in patients with atrophied mandibles. Ten participants with severely resorbed mandibles and persistent denture problems received new maxillary and mandibular conventional dentures (control, CD). After 3 months of adaptation, two implants were inserted in canine region of the mandible. In a quasi-random method, overdentures were connected to the implants with either bar overdentures (BOD) or resilient telescopic overdentures (TOD) attachment systems. Chewing efficiency in terms of unmixed fraction (UF) was measured using chewing gum (after 5, 10, 20, 30 and 50 strokes), and MBF was measured using a bite force transducer. Measurements were performed 3 months after using each of the following prostheses: CD, BOD and TOD. Chewing efficiency and MBF increased significantly with BOD and TOD compared to CD. As the number of chewing cycles increased, the UF decreased. TOD recorded significant higher chewing efficiency and MBF than BOD. Resilient telescopic attachments are associated with increased chewing efficiency and MBF compared bar attachments when used to retain overdentures to the implants in patients with atrophied mandibles. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Application of sintered titanium alloys to metal denture bases: a study of titanium powder sheets for complete denture base.

    PubMed

    Doi, H; Harrori, M; Hasegawa, K; Yoshinari, M; Kawada, E; Oda, Y

    2001-02-01

    The purpose of this study was the fabrication of titanium powder sheets to enable the application of sintered titanium alloys as metal denture bases. The effects of titanium particle shape and size, binder content, and plasticizer content on the surface smoothness, tensile strength and elongation of titanium powder sheets was investigated. To select a suitable ratio of powdered metal contents for application as a metal denture base, the effects of aluminum content in Ti sheets and various other powder metal contents in Ti-Al sheets on the density, sintering shrinkage, and bending strength were evaluated. Based on the results of the above experiments, we developed a mixed powder sheet composed of 83Ti-7Al-10Cr with TA45 titanium powder (atomized, -45 microm), and 8 mass% binder content. This titanium alloy sheet had good formability and ductility. Its sintered titanium alloy had a density of 3.2 g/cm3, sintering shrinkage of 3.8%, and bending strength of 403 MPa. The titanium alloy sheet is clinically acceptable for fabricating denture bases.

  6. Incorporation of Radio Frequency Identification Tag in Dentures to Facilitate Recognition and Forensic Human Identification

    PubMed Central

    Nuzzolese, E; Marcario, V; Di Vella, G

    2010-01-01

    Forensic identification using odontology is based on the comparison of ante-mortem and post mortem dental records. The insertion of a radio frequency identification (RFId) tag into dentures could be used as an aid to identify decomposed bodies, by storing personal identification data in a small transponder that can be radio-transmitted to a reader connected to a computer. A small passive, 12 x 2,1 mm, read-only RFId-tag was incorporated into the manufacture of three trial complete upper dentures and tested for a signal. The aim of this article is to demonstrate the feasibility of manufacturing such a dental prosthesis, the technical protocols for its implantation in the denture resin and its working principles. Future research and tests are required in order to verify human compatibility of the tagged denture and also to evaluate any potential deterioration in strength when subjected to high temperatures, or for damage resulting from everyday wear and tear. It should also be able to withstand the extreme conditions resulting from major accidents or mass disasters and procedures used to perform a forensic identification. PMID:20657641

  7. Occlusion of artificial teeth in partial dentures in the "chewing center"--first exploratory population-based evaluations.

    PubMed

    Kordass, B; Ruge, S; Quooss, A; Hugger, A; Mundt, T

    2014-01-01

    Occlusal performance is a substantial determinant of the quality of dental prosthetic restorations. In the follow-up (SHIP 1) to the Study of Health in Pomerania (SHIP), a representative population of 3300 subjects was studied in the first exploratory evaluation of the occlusion of artificial teeth in the chewing center (first molar region) of partial dentures. A digital analysis of interocclusal records of habitual intercuspation position (ICP) was performed using the Greifswald Digital Analyzing System (GEDAS), a software package that identifies contact points as transparent areas. 562 subjects (280 men aged 61.7 ± 11.9 years and 282 women aged 60.7 ± 10.7 years) had maxillary removable partial dentures (RPDs), and 619 (271 men aged 65.0 ± 11.5 years and 348 women aged 62.4 ± 10.6 years) had mandibular RPDs. Most RPDs were retained with either attachment retainers (11.7% maxilla, 11.7% mandible), cast clasps (38.4% maxilla, 40.7% mandible), telescopes with double crowns (15.7% maxilla, 19.1% mandible), or wrought wire clasps (16.4% maxilla, 8.2% mandible). Some had a combination of different retention elements. The mean number of artificial teeth was 7.8 ± 2.9 in the maxilla and 7.5 ± 3.0 in the mandible. Only the artificial teeth (first molars) in mandibular partial dentures showed differences in the frequency of occlusal contacts between groups (chi-square test). Of these, telescopic crown-retained RPDs had the highest frequency of occlusal contacts (74.4% at tooth 36 and 77.1% at tooth 46), and wrought wire-retained RPDs had the lowest (48.4% at tooth 36 and 45.2% at tooth 46). The results for RPDs with a free-end saddle were comparable and analogous; contact frequencies for those with an interdental saddle did not differ significantly. Notably, the overall frequency of occlusal contacts was greater for tooth 46 (62.9%) than for tooth 36. In conclusion, when replacing teeth in the chewing center, particularly in the mandible, telescopic crown-retained RPDs offer a distinct advantage in terms of occlusal contacts and thus provide better occlusal stability.

  8. Treatment of epulis fissuratum with CO2 laser and prosthetic rehabilitation in patients with vesiculobullous disease.

    PubMed

    Işeri, Ufuk; Ozçakir-Tomruk, Ceyda; Gürsoy-Mert, Hare

    2009-08-01

    The purpose of this article is the clinical presentation of the treatment of epulis fissuratum with CO(2) laser and prosthetic rehabilitation of three patients with vesiculobullous diseases (VBDs). Oral problems such as blister formation with minimal trauma are usually encountered in the VBDs. With repeated cycles of blistering and healing, oral hygiene is usually compromised, which leads to rapid breakdown of the dentition. Prosthetic rehabilitation includes complete, partial, and implant-supported dentures; however, ill-fitting dentures can cause inflammatory fibrous hyperplasia. Clinical application of CO(2) laser has been recommended to treat benign oral lesions such as epulis fissuratum and fibroma. The treatment plan consisted of excision of fibrous tissues, controlling dental plaque, and prosthetic rehabilitation. The excision of fibrous tissue was performed with CO(2) laser, and the wounds formed by laser were left open to secondary epithelization. The dental plaque and calculus deposits were cleaned with ultrasonic scalers and a well-formed acrylic denture for maxilla and mandible were fabricated after a month. There was no recurrent fibrous tissue formation at 1 year follow-up. However, plaque accumulation control was unsatisfactory and the patients were therefore urged to undergo a regular 6-month preventive dental prophylaxis regimen and denture re-evaluation. The CO(2) laser may be a useful instrument in the treatment of soft tissue pathologies in VBDs patients due to minimal damage to surrounding tissue. Use of complete or partial dentures has been considered a practical, economic, and nonsurgical treatment option for patients who have been diagnosed with VBDs.

  9. Flipped clinical training: a structured training method for undergraduates in complete denture prosthesis.

    PubMed

    K, Anbarasi; K, Kasim Mohamed; Vijayaraghavan, Phagalvarthy; Kandaswamy, Deivanayagam

    2016-12-01

    To design and implement flipped clinical training for undergraduate dental students in removable complete denture treatment and predict its effectiveness by comparing the assessment results of students trained by flipped and traditional methods. Flipped training was designed by shifting the learning from clinics to learning center (phase I) and by preserving the practice in clinics (phase II). In phase I, student-faculty interactive session was arranged to recap prior knowledge. This is followed by a display of audio synchronized video demonstration of the procedure in a repeatable way and subsequent display of possible errors that may occur in treatment with guidelines to overcome such errors. In phase II, live demonstration of the procedure was given. Students were asked to treat three patients under instructor's supervision. The summative assessment was conducted by applying the same checklist criterion and rubric scoring used for the traditional method. Assessment results of three batches of students trained by flipped method (study group) and three traditionally trained previous batches (control group) were taken for comparison by chi-square test. The sum of traditionally trained three batch students who prepared acceptable dentures (score: 2 and 3) and unacceptable dentures (score: 1) was compared with the same of flipped trained three batch students revealed that the number of students who demonstrated competency by preparing acceptable dentures was higher for flipped training (χ 2 =30.996 with p<0.001). The results reveal the supremacy of flipped training in enhancing students competency and hence recommended for training various clinical procedures.

  10. The physical mechanisms of complete denture retention.

    PubMed

    Darvell, B W; Clark, R K

    2000-09-09

    The purpose of this article is to assist the practitioner to understand which factors are relevant to complete denture retention in the light of the current understanding of physics and materials science and thus to guide design. Atmospheric pressure, vacuum, adhesion, cohesion, surface tension, viscosity, base adaption, border seal, seating force and muscular control have all been cited at one time or another as major or contributory factors, but usually as an opinion without proper reference to fundamental principles. Although there has been a detailed analysis published, it seems appropriate that a restatement of the points in a collated form be made. In fact, denture retention is a dynamic issue dependent on the control of the flow of interposed fluid and thus its viscosity and film thickness, while the timescale of displacement loading affects the assessment. Surface tension forces at the periphery contribute to retention, but the most important concerns are good base adaptation and border seal. These must be achieved if full advantage is to be taken of the saliva flow-related effects.

  11. A complete denture impression technique survey of postdoctoral prosthodontic programs in the United States.

    PubMed

    Mehra, Mamta; Vahidi, Farhad; Berg, Robert W

    2014-06-01

    The purpose of the study was to survey program directors of postdoctoral prosthodontic programs in the United States regarding their programs' complete denture impression techniques. The key objectives of the survey were to identify the current trends in complete denture impression making and to determine which techniques and materials are taught in US postdoctoral prosthodontic programs. An online survey was sent to all program directors of US postdoctoral prosthodontic programs. The survey comprised two sections: preliminary impressions and final impressions. The survey contained 22 questions that would take approximately 5 minutes to complete. All responses remained anonymous throughout the survey. The response rate for the survey was 87%. A majority of the programs did not separately border mold the tray prior to making the preliminary impressions (82%). The impression material of choice for the preliminary impression was irreversible hydrocolloid (88%). Selective pressure was the predominantly used impression philosophy (80%). All programs border molded the custom tray, and 95% recorded the borders in sections. The material of choice for border molding the custom tray was modeling plastic impression compound (71%). The most commonly used impression material for the final impressions was polyvinylsiloxane (PVS) (42%), and the second most commonly used impression material was polysulphide (32%). The most common technique for locating the posterior palatal seal was marking intraorally and transferring onto the final impression (65%). Most programs routinely advised their patients not to wear their existing dentures for at least 24 hours before the final impressions were made (83%). Based on the results of this study, the following conclusions can be drawn: (1) The most commonly used material for the preliminary impression was irreversible hydrocolloid and for the final impression was PVS. (2) Modeling plastic impression compound was used by most programs to border mold the custom trays. (3) Selective pressure was the predominantly used impression philosophy. (4) A majority of the programs made a special consideration for excessive movable (flabby) tissue. (5) Most programs routinely advised their patients to not wear their existing dentures for at least 24 hours before the final impressions were made. © 2013 by the American College of Prosthodontists.

  12. Maxillary growth after the use of protraction head gear in conjunction with presurgical orthopedics and gingivoperiosteoplasty for complete bilateral cleft lip and alveolus patients.

    PubMed

    Kobayashi, Shinji; Hirakawa, Takashi; Fukawa, Toshihiko; Maegawa, Jiro

    2013-09-01

    Maxillary development is often inadequate in bilateral cleft patients. The use of presurgical orthopedics (PSO) and gingivoperiosteoplasty (GPP) may promote bone formation at the alveolar cleft, but can also have detrimental effects on maxillary development. Our objective was to investigate the effect of PSO and GPP on maxillary development in bilateral cleft lip and alveolus (BCLA) patients. We had 3 complete BCLA patients who had received PSO. All patients underwent cheiloplasty and GPP simultaneously. At 4 years, maxillary protraction head gear was used as part of the protocol. They were evaluated by cephalometric analysis at 4 and 8 years of age, and by CT imaging at 5 years of age. At 4 years of age, patients with all BCLA had anterior crossbite of deciduous central incisors. As a result of maxillary protraction, jaw development at 8 years was good. Among all patients, only one showed bone formation at the alveolar cleft sufficient to avoid alveolar bone grafting (ABG). All patients presented anterior crossbite in the premaxillary region, but had good maxillary growth at 8 years old as a result of maxillary protraction. The combination of PSO and GPP can potentially eliminate the need for ABG and does not significantly retard maxillary development. PSO with GPP and protraction head gear may be an option, but long-term growth is not known.

  13. Patients with burning mouth sensations. A clinical investigation of causative factors in a group of "compete denture wearers" Jordanian population.

    PubMed

    Mukatash-Nimri, Gadeer Elea; Al-Nimri, Marwan A; Al-Jadeed, Omar G; Al-Zobe, Zaid R; Aburumman, Khuzama K; Masarwa, Nader A

    2017-01-01

    To find out the prevalence of "true" burning mouth syndrome and study the association between patients' spontaneous complaints of burning mouth and systemic conditions in a group of middle age and elderly "denture wearers" patients in Jordan. A group of 129 patients (112 female and 17 male) of "complete denture wearers" subjects aged 40 years and over attended prosthetic clinic at King Hussein Medical Hospital complaining from oral burning, with no oral lesion possibly responsible for the burning sensations were selected. Assessment of oral and general status was done based on questioners, detailed history taking, medical records and extra and intraoral examination. The existed complete dentures retention, stability, jaw relationship and the free way space were evaluated. The current blood test and instrumental protocol for examination of patients with burning mouth complains were performed for each patient. Then those studied patients with burning mouth sensations including "true" burning mouth syndrome have been compared to the controls with regard to the presence of local problem, undermined local, systemic or psychological disease. The diagnosis of "true" burning mouth syndrome was established in (2.3%) of the studied population two females and one male. In most patients (58%) more than one site was affected. Significant positive associations were found between local factors (i.e., wearing complete dentures with unsatisfactory retention or jaw relationship, dry mouth or candidasis) and patients suffering from burning mouth sensation. The results also show that some systemic or psychological disorders were significantly more present among patients with burning mouth symptoms when compared to the control group ( p  < 0.05). Spontaneous symptoms of burning mouth without mucosal signs should be considered as a manifestation of undermind pathology and/or distress, and the multi-factorial causes of burning mouth syndrome and sensation need to be referred to the suitable specialist for better treatment results.

  14. Evaluation of wetting ability of five new saliva substitutes on heat-polymerized acrylic resin for retention of complete dentures in dry mouth patients: a comparative study

    PubMed Central

    Mohsin, Abdul Habeeb Bin; Reddy, Varalakshmi; Kumar, Praveen; Raj, Jeevan; Babu, Siva Santosh

    2017-01-01

    Introduction The aim of this study was to evaluate & compare the wetting ability of five saliva substitutes & distilled water on heat-polymerized acrylic resin. Contact angle of the saliva substitute on denture base can be taken as an indicator of wettability. Good wetting of heat-polymerized acrylic resin is critical for optimum retention of complete dentures. Methods Two hundred & forty samples of heat-polymerized acrylic resin were fabricated using conventional method. 240 samples divided into 6 groups with 40 samples in each group. Advancing & Receding contact angles were measured using Contact Angle Goniometer & DSA4 software analysis. Results Anova test was carried out to test the significance in difference of contact angle values in the six groups. The mean of advancing angle values & mean of receding angle values of all the six groups has shown statistically significant difference between the groups. The mean of angle of hysteresis values of all the six groups are statistically not significant between the groups. A multiple comparison using Bonferroni’s test was carried out to verify the significance of difference between the contact angles in a pair of groups. Statistically significant difference was seen when Aqwet (Group II) was compared to Distilled water (Group I), Wet Mouth (Group III), E-Saliva (Group IV), Biotene (Group V), and Moi-Stir (Group VI). Conclusion The contact angles of five saliva substitutes and distilled water were measured and compared. Group II (AQWET) has the lowest advancing and receding contact angle values and the highest angle of hysteresis on heat-polymerized acrylic resin. Based on contact angle values, Group II (AQWET) has the best wetting ability on heat-cured acrylic resins. The ability of saliva to wet the denture surface is one of the most important properties for complete denture retention in dry mouth cases. PMID:29187918

  15. Free Gingival Graft to Increase Keratinized Mucosa after Placing of Mandibular Fixed Implant-Supported Prosthesis

    PubMed Central

    Marcantonio, Elcio

    2017-01-01

    Insufficiently keratinized tissue can be increased surgically by free gingival grafting. The presence or reconstruction of keratinized mucosa around the implant can facilitate restorative procedure and allow the maintenance of an oral hygiene routine without irritation or discomfort to the patient. The aim of this clinical case report is to describe an oral rehabilitation procedure of an edentulous patient with absence of keratinized mucosa in the interforaminal area, using a free gingival graft associated with a mandibular fixed implant-supported prosthesis. The treatment included the manufacturing of a maxillary complete denture and a mandibular fixed implant-supported prosthesis followed by a free gingival graft to increase the width of the mandibular keratinized mucosa. Free gingival graft was obtained from the palate and grafted on the buccal side of interforaminal area. The follow-up of 02 and 12 months after mucogingival surgery showed that the free gingival graft promoted peri-implant health, hygiene, and patient comfort. Clinical Significance. The free gingival graft is an effective treatment in increasing the width of mandibular keratinized mucosa on the buccal side of the interforaminal area and provided an improvement in maintaining the health of peri-implant tissues which allows for better oral hygiene. PMID:28293441

  16. Complete Overlay Denture for Pedodontic Patient with Severe Dentinogenesis Imperfecta

    PubMed Central

    Joseph, Elizabeth; Rupesh, Suresh; Mathew, Josey

    2017-01-01

    Dentinogenesis imperfecta (DI) is a hereditary condition that may affect both primary and permanent dentition and is characterized by abnormal dentin formation. The teeth may be discolored with chipping of enamel and, in untreated cases, the entire dentition may wear off to the gingiva. This may lead to the formation of abscesses, tooth mobility, and early loss of teeth. In the Indian population, DI is found to have an incidence of 0.09%. Treatment of DI should aim to remove infection, if any, from the oral cavity; restore form, function, and esthetics; and protect posterior teeth from wear for maintaining the occlusal vertical dimension. Treatment strategies should be selected based on the presenting complaint of the patient, patient’s age, and severity of the problem. This case report presents the management of severe DI with tooth worn off until gingival level in a very young patient using complete overlay denture, which has not been reported earlier. How to cite this article: Syriac G, Joseph E, Rupesh S, Mathew J. Complete Overlay Denture for Pedodontic Patient with Severe Dentinogenesis Imperfecta. Int J Clin Pediatr Dent 2017;10(4):394-398. PMID:29403236

  17. Head and cervical spine postures in complete denture wearers.

    PubMed

    Salonen, M A; Raustia, A M; Huggare, J

    1993-01-01

    Signs and symptoms in the stomatognathic system and head and cervical spine postures were evaluated in 10 edentulous patients prior to renewal of their dentures, as well as immediately and six months after insertion of new dentures. Natural head posture was recorded using the fluid-level method and measured from the roentgen cephalograms. It was shown that the variables duration of edentulousness and free-way space displayed positive correlations with the dysfunction symptoms. In addition, the patients who needed oral rehabilitation the most, who received the greatest reduction in their free-way space, were seen to have raised their heads more than average. There was also an inverse correlation between the reduction of clinical dysfunction index score and cervical spine postures.

  18. Composite resin root coping with a keeper for magnetic attachment for replacing the missing coronal portion of a removable partial denture abutment.

    PubMed

    Maeda, Yoshinobu; Nakao, Katsuhiko; Yagi, Kazutomo; Matsuda, Shisuke

    2006-08-01

    Numerous methods for replacing missing removable partial denture abutments have been introduced, however, most of them are time consuming and require several visits to complete the procedure. Since magnetic attachments can provide support and bracing as well as retention for overdenture abutments, the remaining tooth root structure can be used to support the coping with the keeper. Through the use of composite resin and adhesive material, improved retention of the keeper to the root may be achieved, along with improved esthetics. This article describes a method for replacing the missing abutment of a removable partial denture with a magnetic attachment, and a composite resin coping with a keeper.

  19. Five-year multicenter study of magnetic attachments used for natural overdenture abutments.

    PubMed

    Gonda, T; Yang, T C; Maeda, Y

    2013-04-01

    The purpose of this study was to examine a longitudinal clinical performance of magnetic attachments used for natural overdenture abutments. The study included 131 patients who had used removable prostheses (complete overdentures 31%, partial dentures 69%) more than 5 years (40-90 years old) with 211 magnetic attachments on natural abutments (Magfit 400 or 600; Aichi Steel co., Aichi, Japan) treated in 15 clinics using a standardized protocol. Analyses were performed on the degree of patient satisfaction regarding retention, complications of magnets (corrosion, detachment from denture base), abutments (pain during mastication, periodontal pocket formation, inflammation, mobility), and dentures (fracture etc.). Ninety-seven percent of patients were satisfied with the retention and stability of their dentures. No corrosion of magnet was observed, and 19 magnets were detached. Most frequent complication of abutments was periodontal pocket formation (52%), followed by the inflammation (29%), increase in mobility (27%) and pain (4%). Magnetic attachment on natural tooth abutments provided a viable and long-term treatment option. © 2013 Blackwell Publishing Ltd.

  20. The Versatility of 980 nm Diode Laser in Dentistry: A Case Series

    PubMed Central

    Derikvand, Nahid; Chinipardaz, Zahra; Ghasemi, Sara; Chiniforush, Nasim

    2016-01-01

    Introduction: Laser surgery has been considered a popular alternative over conventional modalities in dentistry during the last few years. Among different types of lasers, diode lasers have gained special attention in oral soft tissue surgery. Case Reports: Five patients were referred to a private office. After careful evaluation of medical history and oral examination, oral diagnosis and treatment plan of each patient was established as follows: (1) A 21-year-old female with ankyloglossia (tongue-tie); (2) A 65-year-old female with a poor denture fit needing vestibuloplasty and frenectomy; (3) A 10-year-old male patient with pigmented gingiva in mandible and maxilla; (4) A 14-year-old female needing exposure of maxillary right canine for bracket bonding; and (5) A 25-year-old female patient who has a gingival maxillary frenum with a nodule. The treatment plan for all the patients was laser surgery with diode laser at 980 nm, in continuous mode. Results: All the patients experienced normal healing process with no postoperative complications. Favorable outcomes of laser surgery were observed on follow-up sessions. Conclusion: Considering the versatility of the 980 nm diode laser in oral soft tissue surgeries and the advantages of laser surgery, this study suggests the use of 980 nm diode laser in this regard. PMID:28144444

  1. The Versatility of 980 nm Diode Laser in Dentistry: A Case Series.

    PubMed

    Derikvand, Nahid; Chinipardaz, Zahra; Ghasemi, Sara; Chiniforush, Nasim

    2016-01-01

    Introduction: Laser surgery has been considered a popular alternative over conventional modalities in dentistry during the last few years. Among different types of lasers, diode lasers have gained special attention in oral soft tissue surgery. Case Reports: Five patients were referred to a private office. After careful evaluation of medical history and oral examination, oral diagnosis and treatment plan of each patient was established as follows: (1) A 21-year-old female with ankyloglossia (tongue-tie); (2) A 65-year-old female with a poor denture fit needing vestibuloplasty and frenectomy; (3) A 10-year-old male patient with pigmented gingiva in mandible and maxilla; (4) A 14-year-old female needing exposure of maxillary right canine for bracket bonding; and (5) A 25-year-old female patient who has a gingival maxillary frenum with a nodule. The treatment plan for all the patients was laser surgery with diode laser at 980 nm, in continuous mode. Results: All the patients experienced normal healing process with no postoperative complications. Favorable outcomes of laser surgery were observed on follow-up sessions. Conclusion: Considering the versatility of the 980 nm diode laser in oral soft tissue surgeries and the advantages of laser surgery, this study suggests the use of 980 nm diode laser in this regard.

  2. Evaluation of Three Different Processing Techniques in the Fabrication of Complete Dentures

    PubMed Central

    Chintalacheruvu, Vamsi Krishna; Balraj, Rajasekaran Uttukuli; Putchala, Lavanya Sireesha; Pachalla, Sreelekha

    2017-01-01

    Aims and Objectives: The objective of the present study is to compare the effectiveness of three different processing techniques and to find out the accuracy of processing techniques through number of occlusal interferences and increase in vertical dimension after denture processing. Materials and Methods: A cross-sectional study was conducted on a sample of 18 patients indicated for complete denture fabrication was selected for the study and they were divided into three subgroups. Three processing techniques, compression molding and injection molding using prepolymerized resin and unpolymerized resin, were used to fabricate dentures for each of the groups. After processing, laboratory-remounted dentures were evaluated for number of occlusal interferences in centric and eccentric relations and change in vertical dimension through vertical pin rise in articulator. Data were analyzed using statistical test ANOVA and SPSS software version 19.0 by IBM was used. Results: Data obtained from three groups were subjected to one-way ANOVA test. After ANOVA test, results with significant variations were subjected to post hoc test. Number of occlusal interferences with compression molding technique was reported to be more in both centric and eccentric positions as compared to the two injection molding techniques with statistical significance in centric, protrusive, right lateral nonworking, and left lateral working positions (P < 0.05). Mean vertical pin rise (0.52 mm) was reported to more in compression molding technique as compared to injection molding techniques, which is statistically significant (P < 0.001). Conclusions: Within the limitations of this study, injection molding techniques exhibited less processing errors as compared to compression molding technique with statistical significance. There was no statistically significant difference in processing errors reported within two injection molding systems. PMID:28713763

  3. Evaluation of Three Different Processing Techniques in the Fabrication of Complete Dentures.

    PubMed

    Chintalacheruvu, Vamsi Krishna; Balraj, Rajasekaran Uttukuli; Putchala, Lavanya Sireesha; Pachalla, Sreelekha

    2017-06-01

    The objective of the present study is to compare the effectiveness of three different processing techniques and to find out the accuracy of processing techniques through number of occlusal interferences and increase in vertical dimension after denture processing. A cross-sectional study was conducted on a sample of 18 patients indicated for complete denture fabrication was selected for the study and they were divided into three subgroups. Three processing techniques, compression molding and injection molding using prepolymerized resin and unpolymerized resin, were used to fabricate dentures for each of the groups. After processing, laboratory-remounted dentures were evaluated for number of occlusal interferences in centric and eccentric relations and change in vertical dimension through vertical pin rise in articulator. Data were analyzed using statistical test ANOVA and SPSS software version 19.0 by IBM was used. Data obtained from three groups were subjected to one-way ANOVA test. After ANOVA test, results with significant variations were subjected to post hoc test. Number of occlusal interferences with compression molding technique was reported to be more in both centric and eccentric positions as compared to the two injection molding techniques with statistical significance in centric, protrusive, right lateral nonworking, and left lateral working positions ( P < 0.05). Mean vertical pin rise (0.52 mm) was reported to more in compression molding technique as compared to injection molding techniques, which is statistically significant ( P < 0.001). Within the limitations of this study, injection molding techniques exhibited less processing errors as compared to compression molding technique with statistical significance. There was no statistically significant difference in processing errors reported within two injection molding systems.

  4. A double blind randomized clinical trial comparing lingualized and fully bilateral balanced posterior occlusion for conventional complete dentures.

    PubMed

    Kawai, Yasuhiko; Ikeguchi, Nobuyuki; Suzuki, Asako; Kuwashima, Azusa; Sakamoto, Ryuji; Matsumaru, Yuichi; Kimoto, Suguru; Iijima, Morio; Feine, Jocelyne Sylvia

    2017-04-01

    A lingualized occlusion (LO) for complete dentures reduces lateral inferences and occlusal force contacts and direction; thus, LO is theorized to be more suitable for patients with compromised ridges than fully bilateral balanced articulation (FBBA). However, no studies have yet provided evidence to support LO in edentate patients with compromised alveolar ridges. The purpose of this study was to compare LO and FBBA in edentulous individuals with compromised ridges. Sixty edentulous individuals were randomly allocated into groups and received dentures with either LO or FBBA. Following delivery, several denture-related satisfaction variables were measured using 100mm visual analogue scales; oral health-related quality of life (OHRQoL) was also assessed using the Oral Health Impact Profile (OHIP). Sub-group analyses of the effect of moderate and severe mandibular bone loss were also carried out. No significant differences were detected between LO and FBBA with the primary outcome. At 6 months, participants with severely atrophied mandibles and FBBA rated their satisfaction with retention of mandibular dentures significantly lower than those with LO (median LO: 86, FBBA: 58.5, p=0.03). They also had significantly lower OHRQoL for the domain of Pain (median LO: 4, FBBA: 5, p=0.02). General satisfaction and total OHIP scores significantly improved between baseline and 6 months only for the LO subjects with severely atrophied mandibles (satisfaction: p=0.003, OHIP total score: p=0.0007). The results indicate that the LO occlusal scheme with hard resin artificial teeth is more efficient for patients with severely resorbed mandibular ridges. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Interim overdentures.

    PubMed

    Fenton, A H

    1976-07-01

    The construction of an interim overdenture using existing removable partial dentures with natural tooth crowns and artificial teeth can be a simple and economical method of providing patients with dentures while tissues heal and teeth are prepared and restored. A more definite prognosis for both the patient and his remaining dentition can be established before the final overdenture is completed. The procedures necessary to provide three types of interim overdentures have been outlined. Patients tolerate this method of changing their dentitions extremely well.

  6. Immediate occlusal loading of NanoTite PREVAIL implants: a prospective 1-year clinical and radiographic study.

    PubMed

    Ostman, Pär-Olov; Wennerberg, Ann; Albrektsson, Tomas

    2010-03-01

    Recently, a new implant surface texture, featuring application of nanometer-scale calcium phosphate has been shown to enhance early bone fixation and formation in preclinical studies and in human histomorphometric studies, which may be beneficial in immediate loading situations. The purpose of the present prospective clinical study was to, during 1 year, clinically and radiographically evaluate a nanometer scale surface modified implant placed for immediate loading of fixed prostheses in both maxillary and mandibular regions. Thirty-five out of 38 patients who needed implant treatment and met inclusion criteria agreed to participate in the study and were consecutively enrolled. Surgical implant placement requirements consisted of a final torque of a least 25 Ncm prior to final seating and an implant stability quotient above 55. A total of 102 NanoTite PREVAIL (NTP) implants (BIOMET 3i, Palm Beach Gardens, FL, USA) (66 maxillary and 36 mandibular) were placed by one investigator, and the majority of these were placed in posterior regions (65%) and in soft bone (69%). A total of 44 prosthetic constructions were evaluated consisting of 14 single-tooth restorations, 26 fixed partial dentures, and four complete fixed restorations. All provisional constructions were delivered within 1 hour, and the final constructions placed after 4 months. Implants were monitored for clinical and radiographic outcomes at follow-up examinations scheduled for 3, 6, and 12 months. Of the 102 study implants, one implant failed. The simple cumulative survival rate value at 1 year was 99.2%. The average marginal bone resorption was 0.37 mm (SD 0.39) during the first year in function. According to the success criteria of Albrektsson and Zarb, success grade 1 was found with 93% of the implants. Although limited to the short follow-up, immediate loading of NanoTite Prevail implants seems to be a viable option in implant rehabilitation, at least when a good initial fixation is achieved.

  7. Rapidly Progressive Maxillary Atelectasis.

    PubMed

    Elkhatib, Ahmad; McMullen, Kyle; Hachem, Ralph Abi; Carrau, Ricardo L; Mastros, Nicholas

    2017-07-01

    Report of a patient with rapidly progressive maxillary atelectasis documented by sequential imaging. A 51-year-old man, presented with left periorbital and retro-orbital pain associated with left nasal obstruction. An initial computed tomographic (CT) scan of the paranasal sinuses failed to reveal any significant abnormality. A subsequent CT scan, indicated for recurrence of symptoms 11 months later, showed significant maxillary atelectasis. An uncinectomy, maxillary antrostomy, and anterior ethmoidectomy resulted in a complete resolution of the symptoms. Chronic maxillary atelectasis is most commonly a consequence of chronic rhinosinusitis. All previous reports have indicated a chronic process but lacked documentation of the course of the disease. This report documents a patient of rapidly progressive chronic maxillary atelectasis with CT scans that demonstrate changes in the maxillary sinus (from normal to atelectatic) within 11 months.

  8. Hypohidrotic ectodermal dysplasia: a clinical case with a longitudinal approach.

    PubMed

    Fraiz, Fabian Calixto; Gugisch, Renato Cordeiro; Cavalcante-Leão, Bianca Lopes; Macedo, Liliane Moreira

    2014-11-01

    This paper describes a clinical case of a male with hypohidrotic ectodermal dysplasia submitted to rehabilitation and occlusal dental interventions with follow-up from 3 to 14 years of age. Due to the severe effects on function and esthetics, the clinical manifestations of ectodermal dysplasia exert a negative impact on quality of life. However, oral rehabilitation in childhood poses a challenge due to growth and development. A male with hypohidrotic ectodermal dysplasia began dental intervention at the age of 3 years. The clinical and radiographic exams revealed the absence of several primary and permanent teeth and abnormal shape of the primary maxillary incisors. The facial characteristics were compatible with hypohidrotic ectodermal dysplasia, such as a prominent brow, everted lips, fattened bridge of the nose and small vertical facial height. The treatment proposed involved rehabilitation through successive temporary partial dentures, functional orthopedics of the jaws, esthetic reconstruction of the anterior teeth, timely occlusal intervention and preventive actions for the control of dental caries and plaque. The present case demonstrates that early care plays a fundamental role in minimizing the biopsychosocial consequences of hypohidrotic ectodermal dysplasia and preparing the patient for future oral rehabilitation. Although, the literature offers a number of papers describing dental treatment for ectodermal dysplasia, few cases include long-term follow-up and the use of a functional orthopedic appliance in combination with removable dentures in such patients.

  9. Comparison of different final impression techniques for management of resorbed mandibular ridge: a case report.

    PubMed

    Yadav, Bhupender; Jayna, Manisha; Yadav, Harish; Suri, Shrey; Phogat, Shefali; Madan, Reshu

    2014-01-01

    The history of complete denture impression procedures has been influenced largely by the development of impression materials from which new techniques and ideas arose. The purpose of this study was to compare the retention of complete dentures made by using different impression techniques like conventional, admixed, all green, and functional techniques. The results showed that there was significant difference in retention between the six techniques where functional technique showed the highest mean value of retention followed by elastomeric, all green, and admixed, while cocktail and green stick compound showed the lowest mean value. However, on clinical examination, the retention produced by the six techniques was satisfactory.

  10. Treatment of Orally Handicapped Edentulous Older Adults Using Dental Implants.

    PubMed

    Zahedi, Charles

    2016-07-01

    The oral handicap of complete edentulism is the terminal outcome of a multifactorial process involving biological factors and patient-related factors. Fully edentulous orally handicapped older adults have been neglected because removable acrylic dentures have been the classic therapy for complete edentulism but are only rehabilitative, not therapeutic. Not replacing missing teeth with stable dentures could prevent adequate food intake. Osseointegrated endosseous implants used as a therapeutic adjunct can reduce the problem of long-term bone resorption to less than 0.1 mm per year. Implant-borne prostheses substantially increase the overall health and quality of life of orally handicapped fully edentulous older adults. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Comparison of Different Final Impression Techniques for Management of Resorbed Mandibular Ridge: A Case Report

    PubMed Central

    Yadav, Bhupender; Jayna, Manisha; Yadav, Harish; Suri, Shrey; Phogat, Shefali; Madan, Reshu

    2014-01-01

    The history of complete denture impression procedures has been influenced largely by the development of impression materials from which new techniques and ideas arose. The purpose of this study was to compare the retention of complete dentures made by using different impression techniques like conventional, admixed, all green, and functional techniques. The results showed that there was significant difference in retention between the six techniques where functional technique showed the highest mean value of retention followed by elastomeric, all green, and admixed, while cocktail and green stick compound showed the lowest mean value. However, on clinical examination, the retention produced by the six techniques was satisfactory. PMID:25180105

  12. A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication.

    PubMed

    Bilgin, Mehmet Selim; Baytaroğlu, Ebru Nur; Erdem, Ali; Dilber, Erhan

    2016-01-01

    The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now.

  13. A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication

    PubMed Central

    Bilgin, Mehmet Selim; Baytaroğlu, Ebru Nur; Erdem, Ali; Dilber, Erhan

    2016-01-01

    The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now. PMID:27095912

  14. Effect of denture cleaning on abrasion resistance and surface topography of polymerized CAD CAM acrylic resin denture base

    PubMed Central

    Shinawi, Lana Ahmed

    2017-01-01

    Background The application of computer-aided design computer-aided manufacturing (CAD CAM) technology in the fabrication of complete dentures, offers numerous advantages as it provides optimum fit and eliminates polymerization shrinkage of the acrylic base. Additionally, the porosity and surface roughness of CAD CAM resins is less compared to conventionally processed resins which leads to a decrease in the adhesion of bacteria on the denture base, which is associated with many conditions including halitosis and aspiration pneumonia in elderly denture wearers. Aim To evaluate the influence of tooth brushing with dentifrices on CAD CAM resin blocks in terms of abrasion resistance, surface roughness and scanning electron photomicrography. Methods This experimental study was carried out at the Faculty of Dentistry of King Abdulaziz University during 2016. A total of 40 rectangular shaped polymerized CAD CAM resin samples were subjected to 40.000 and 60.000 brushing strokes under a 200-gram vertical load simulating three years of tooth brushing strokes using commercially available denture cleaning dentifrice. Data were analyzed by SPSS version 20, using descriptive statistics and ANOVA. Results ANOVA test revealed a statistical significant weight loss of CAD CAM acrylic resin denture base specimens following 40.000 and 60.000 brushing strokes as well as a statistical significant change (p=0.0.5) in the surface roughness following brushing. The CAD CAM resin samples SEM baseline imaging revealed a relatively smooth homogenous surface, but following 40,000 and 60,000 brushing strokes, imaging displayed the presence of small scratches on the surface. Conclusion CAD CAM resin displayed a homogenous surface initially with low surface roughness that was significantly affected following simulating three years of manual brushing, but despite the significant weight loss, the findings are within the clinically acceptable limits. PMID:28713496

  15. Effect of denture cleaning on abrasion resistance and surface topography of polymerized CAD CAM acrylic resin denture base.

    PubMed

    Shinawi, Lana Ahmed

    2017-05-01

    The application of computer-aided design computer-aided manufacturing (CAD CAM) technology in the fabrication of complete dentures, offers numerous advantages as it provides optimum fit and eliminates polymerization shrinkage of the acrylic base. Additionally, the porosity and surface roughness of CAD CAM resins is less compared to conventionally processed resins which leads to a decrease in the adhesion of bacteria on the denture base, which is associated with many conditions including halitosis and aspiration pneumonia in elderly denture wearers. To evaluate the influence of tooth brushing with dentifrices on CAD CAM resin blocks in terms of abrasion resistance, surface roughness and scanning electron photomicrography. This experimental study was carried out at the Faculty of Dentistry of King Abdulaziz University during 2016. A total of 40 rectangular shaped polymerized CAD CAM resin samples were subjected to 40.000 and 60.000 brushing strokes under a 200-gram vertical load simulating three years of tooth brushing strokes using commercially available denture cleaning dentifrice. Data were analyzed by SPSS version 20, using descriptive statistics and ANOVA. ANOVA test revealed a statistical significant weight loss of CAD CAM acrylic resin denture base specimens following 40.000 and 60.000 brushing strokes as well as a statistical significant change (p=0.0.5) in the surface roughness following brushing. The CAD CAM resin samples SEM baseline imaging revealed a relatively smooth homogenous surface, but following 40,000 and 60,000 brushing strokes, imaging displayed the presence of small scratches on the surface. CAD CAM resin displayed a homogenous surface initially with low surface roughness that was significantly affected following simulating three years of manual brushing, but despite the significant weight loss, the findings are within the clinically acceptable limits.

  16. Estimate of Impact on the Oral Health-Related Quality of Life of Older Thai People by the Provision of Dentures through the Royal Project.

    PubMed

    Srisilapanan, Patcharawan; Korwanich, Narumanas; Jienmaneechotchai, Sutha; Dalodom, Supranee; Veerachai, Nontalee; Vejvitee, Warangkana; Roseman, Jeffrey

    2016-01-01

    Purpose. To estimate the impact of the provision of dentures to Thai older people by the Royal Project on their oral health-related quality of life. Methods. A purposive cross-sectional study of a sample of 812 subjects was conducted. The Oral Impacts on Daily Performances (OIDP) measure was used to assess the oral health-related quality of life. Results. Four groups of older people with different tooth types were studied. 216 (26.6%) had natural teeth (NT). 189 (23.3%) had natural and replaced teeth (NRT). 167 (20.6%) had below the minimum number of teeth but had no dentures (Edent) and 240 were edentate with complete dentures provided by the Royal Project (ECD) (29.6%). Overall, 36.5% had at least one oral impact. Eating was the most affected oral impact. When compared to the group with natural teeth (NT), the Edent group was significantly more likely to report having impacts on eating OR = 6.5 (3.9-10.9), speaking clearly OR = 43.7 (12.7-15.07), emotional stability OR = 16.5 (6.0-45.6), and social contacts OR = 4.6 (2.2-9.5) (p < 0.001). Conclusion. Those who are edentulous are much more likely to have an oral impact on their daily performances than those provided dentures. Provision of dentures may lead to improvement of considerable oral impacts.

  17. Is the Maxillary Sinus Really Suitable in Sex Determination? A Three-Dimensional Analysis of Maxillary Sinus Volume and Surface Depending on Sex and Dentition.

    PubMed

    Möhlhenrich, Stephan Christian; Heussen, Nicole; Peters, Florian; Steiner, Timm; Hölzle, Frank; Modabber, Ali

    2015-11-01

    The morphometric analysis of maxillary sinus was recently presented as a helpful instrument for sex determination. The aim of the present study was to examine the volume and surface of the fully dentate, partial, and complete edentulous maxillary sinus depending on the sex. Computed tomography data from 276 patients were imported in DICOM format via special virtual planning software, and surfaces (mm) and volumes (mm) of maxillary sinuses were measured. In sex-specific comparisons (women vs men), statistically significant differences for the mean maxillary sinus volume and surface were found between fully dentate (volume, 13,267.77 mm vs 16,623.17 mm, P < 0.0001; surface, 3480.05 mm vs 4100.83 mm, P < 0.0001) and partially edentulous (volume, 10,577.35 mm vs 14,608.10 mm, P = 0.0002; surface, 2980.11 mm vs 3797.42 mm, P < 0.0001) or complete edentulous sinuses (volume, 11,200.99 mm vs 15,382.29 mm, P < 0.0001; surface, 3118.32 mm vs 3877.25 mm, P < 0.0001). For males, the statistically different mean values were calculated between fully dentate and partially edentulous (volume, P = 0.0022; surface, P = 0.0048) maxillary sinuses. Between the sexes, no differences were only measured for female and male partially dentate fully edentulous sinuses (2 teeth missing) and between partially edentulous sinuses in women and men (1 teeth vs 2 teeth missing). With a corresponding software program, it is possible to analyze the maxillary sinus precisely. The dentition influences the volume and surface of the pneumatic maxillary sinus. Therefore, sex determination is possible by analysis of the maxillary sinus event through the increase in pneumatization.

  18. Maxillary growth after maxillary protraction: Appliance in conjunction with presurgical orthopedics, gingivoperiosteoplasty, and Furlow palatoplasty for complete bilateral cleft lip and palate patients with protruded premaxilla.

    PubMed

    Kobayashi, Shinji; Hirakawa, Takashi; Fukawa, Toshihiko; Maegawa, Jiro

    2015-06-01

    In bilateral cleft lip and palate (BCLP) with premaxillary protrusion, a good outcome with adequate maxillary development is difficult to achieve. The purpose of this article is to evaluate the maxillary growth after using presurgical orthopedics (PSO), gingivoperiosteoplasty (GPP), Furlow palatoplasty, and maxillary protraction appliance (MPA) for BCLP with premaxillary protrusion. Seven patients with complete BCLP with premaxillary protrusion were treated by PSO, cheiloplasty, GPP, and Furlow palatoplasty. MPA was used as part of the protocol for 6 months to 1 year for postoperative retardation of maxillary growth cases. Maxillary growth was evaluated by cephalometric analysis at 4 and 10 years of age, and bone formation at the alveolar cleft was evaluated by computed tomography (CT) imaging at 5 years of age. At 4 years of age, three of seven patients had apparent retardation of maxillary growth. The maxillary growth at 10 years of age was equivalent to the average value of normal Japanese after using MPA in three cases. At 5 years of age, only two of seven patients showed sufficient bone formation at the alveolar cleft to avoid alveolar bone grafting (ABG). Subsequently, ABG was performed in five patients. Although three of seven patients had apparent crossbite at 4 years of age, the maxillary growth of all patients at 10 years of age was approximately equivalent to the average value of normal Japanese after using MPA. A treatment protocol based on PSO, GPP, Furlow palatoplasty, and MPA may be an option, but long-term growth is unknown. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  19. Long-term follow-up of early cleft maxillary distraction.

    PubMed

    Park, Young-Wook; Kwon, Kwang-Jun; Kim, Min-Keun

    2016-12-01

    Most of cleft lip and palate patients have the esthetic and functional problems of midfacial deficiencies due to innate developmental tendency and scar tissues from repeated operations. In these cases, maxillary protraction is required for the harmonious facial esthetics and functional occlusion. A 7-year old boy had been diagnosed as severe maxillary constriction due to unilateral complete cleft lip and palate. The author tried to correct the secondary deformity by early distraction osteogenesis with the aim of avoiding marked psychological impact from peers of elementary school. From 1999 to 2006, repeated treatments, which consisted of Le Fort I osteotomy and face mask distraction, and complementary maxillary protraction using miniplates were performed including orthodontics. But, final facial profile was not satisfactory, which needs compromising surgery. The result of this study suggests that if early distraction treatment is performed before facial skeletal growth is completed, an orthognathic surgery or additional distraction may be needed later. Maxillofacial plastic and reconstructive surgeons should notify this point when they plan early distraction treatment for cleft maxillary deformity.

  20. Using CAD/CAM technology to create a 10-unit zirconia fixed partial denture--a UTHSCSA dental school case report.

    PubMed

    Zimmermann, Richard; Seitz, Stefanie; Magness, Brent; Wieck, Blaine

    2013-10-01

    From diagnosis and treatment planning to the materials being used, technology is changing dentistry. New materials are providing dentists greater options for treatment, while technology is streamlining the workflow in the office and dental laboratory. Traditionally the creation of a long-span fixed partial denture was a labor intense project--from waxing up the prosthesis--to stacking of the porecelain. For larger frameworks, it was recommended for the dentist to bring in the patient in for a framework try-in. However, advances in both CAD/CAM technology and dental materials are revolutionizing the way dentistry is being done. The following describes the fabrication of a 10-unit full contour zirconia fixed partial denture completed in the pre-doctorate program at UTHSCSA Dental School.

  1. Present status of titanium removable dentures--a review of the literature.

    PubMed

    Ohkubo, C; Hanatani, S; Hosoi, T

    2008-09-01

    Although porcelain and zirconium oxide might be used for fixed partial dental prostheses instead of conventional dental metals in the near future, removable partial denture (RPD) frameworks will probably continue to be cast with biocompatible metals. Commercially pure (CP) titanium has appropriate mechanical properties, it is lightweight (low density) compared with conventional dental alloys, and has outstanding biocompatibility that prevents metal allergic reactions. This literature review describes the laboratory conditions needed for fabricating titanium frameworks and the present status of titanium removable prostheses. The use of titanium for the production of cast RPD frameworks has gradually increased. There are no reports about metallic allergy apparently caused by CP titanium dentures. The laboratory drawbacks still remain, such as the lengthy burn-out, inferior castability and machinability, reaction layer formed on the cast surface, difficulty of polishing, and high initial costs. However, the clinical problems, such as discoloration of the titanium surfaces, unpleasant metal taste, decrease of clasp retention, tendency for plaque to adhere to the surface, detachment of the denture base resin, and severe wear of titanium teeth, have gradually been resolved. Titanium RPD frameworks have never been reported to fail catastrophically. Thus, titanium is recommended as protection against metal allergy, particularly for large-sized prostheses such as RPDs or complete dentures.

  2. Imaging technique for the complete edentulous patient treated conventionally or with mini implant overdenture

    PubMed Central

    Meleşcanu Imre, M; Preoteasa, E; Țâncu, AM; Preoteasa, CT

    2013-01-01

    Rationale. The imaging methods are more and more used in the clinical process of modern dentistry. Once the implant based treatment alternatives are nowadays seen as being the standard of care in edentulous patients, these techniques must be integrated in the complete denture treatment. Aim. The study presents some evaluation techniques for the edentulous patient treated by conventional dentures or mini dental implants (mini SKY Bredent) overdentures, using the profile teleradiography. These offer data useful for an optimal positioning of the artificial teeth and the mini dental implants, favoring to obtain an esthetic and functional treatment outcome. We proposed also a method to conceive a simple surgical guide that allows the prosthetically driven implants placement. Material and method. Clinical case reports were made, highlighting the importance of cephalometric evaluation on lateral teleradiographs in complete edentulous patients. A clinical case that gradually reports the surgical guide preparation (Bredent silicon radio opaque), in order to place the mini dental implants in the best prosthetic and anatomic conditions, was presented. Conclusions. The profile teleradiograph is a useful tool for the practitioner. It allows establishing the optimal site for implant placement, in a good relation with the overdenture. The conventional denture can be easily and relatively costless transformed in a surgical guide used during implant placement. PMID:23599828

  3. Complete denture impression techniques: evidence-based or philosophical.

    PubMed

    Singla, Shefali

    2007-01-01

    Code of practice is dangerous and ever-changing in today's world. Relating this to complete denture impression technique, we have been provided with a set of philosophies--"no pressure, minimal pressure, definite pressure and selective pressure". The objectives and principles of impression-making have been clearly defined. Do you think any philosophy can satisfy any operator to work on these principles and achieve these objectives? These philosophies take into consideration only the tissue part and not the complete basal seat, which comprises the periphery, the tissues and the bone structure. Under such circumstances, should we consider a code of practice dangerous or should we develop an evidence-based approach having a scientific background following certain principles, providing the flexibility to adapt to clinical procedures and to normal biological variations in patients rather than the rigidity imposed by strict laws?

  4. Trans-sinusal maxillary distraction for correction of midfacial hypoplasia: long-term clinical results.

    PubMed

    Nadjmi, N; Schutyser, F; Van Erum, R

    2006-10-01

    Maxillary distraction osteogenesis is indicated in severe angle class III malocclusions, and severe maxillary hypoplasia among some cleft patients and other craniofacial deformities. Twenty patients, aged 8-48 years (mean 17.8+/-10.5 SD) with maxillary and midfacial hypoplasia were treated. The follow-up period was 13-65 months (mean 35+/-16.3 SD). A trans-sinusal maxillary distractor was placed intraorally at each side of the maxilla. The distraction vector was predicted using specialist software, and was transferred to the patients using stereolithographic models and individual templates. A (high) Le Fort I type osteotomy was performed. The amount of activation varied from 8 to 17.5 mm (mean 13.1+/-2.9 SD). Soft and hard tissue formation resulted in complete healing across the distraction gaps. The distractors are almost completely submerged, and can be left in place as long as necessary to avoid relapse. Wit's appraisal was used to measure the stability of the long-term distraction results. Results up to 5 years after distraction showed considerable maxillary advancement with long-term stability. Ongoing growth of the facial skeleton must be considered when distraction osteogenesis is chosen in growing patients.

  5. Denture-related hyperplasia: a clinical study of a Turkish population group.

    PubMed

    Canger, Emin Murat; Celenk, Peruze; Kayipmaz, Saadettin

    2009-01-01

    Inflammatory fibrous hyperplasia (epulis fissuratum) (IFH) and inflammatory papillary hyperplasia (IPH) are oral mucosal diseases caused by ill-fitting denture wearing. A study was carried out on a group of Turkish people consisted of 131 female and 39 male complete denture wearers (n= 170) distributed in two age groups (30-60 and 60-80 years old). The analysis of data collected from patients showed that while the incidence of IFH was higher in women than in men, the incidence of IPH was similar. Most lesions were found in the 30-60 year-old group. The incidence of lesions increased as the denture wearing period increased. Soft tissue growth was the main complaint of the patients with IFH and IPH. In the maxilla, the incidence of IFH was higher than IPH. There was also a significant difference between the distribution of the lesion types in the jaws. There were a larger number of lesions in the maxilla compared to the mandible and most IFH lesions were located in the anterior region of the jaws.

  6. Long-Term Soft Denture Lining Materials

    PubMed Central

    Chladek, Grzegorz; Żmudzki, Jarosław; Kasperski, Jacek

    2014-01-01

    Long-term soft denture lining (LTSDL) materials are used to alleviate the trauma associated with wearing complete dentures. Despite their established clinical efficacy, the use of LTSDLs has been limited due to the unfavorable effects of the oral environment on some of their mechanical and performance characteristics. The unresolved issue of LTSDL colonization by Candida albicans is particularly problematic. Silicone-based LTSDL (SLTSDL) materials, which are characterized by more stable hardness, sorption and solubility than acrylic-based LTSDLs (ALTSDLs), are currently the most commonly used LTSDLs. However, SLTSDLs are more prone to debonding from the denture base. Moreover, due to their limitations, the available methods for determining bond strength do not fully reflect the actual stability of these materials under clinical conditions. SLTSDL materials exhibit favorable viscoelastic properties compared with ALTSDLs. Furthermore, all of the lining materials exhibit an aging solution-specific tendency toward discoloration, and the available cleansers are not fully effective and can alter the mechanical properties of LTSDLs. Future studies are needed to improve the microbiological resistance of LTSDLs, as well as some of their performance characteristics. PMID:28788163

  7. Reappraisal of the envenoming capacity of Euchambersia mirabilis (Therapsida, Therocephalia) using μCT-scanning techniques

    PubMed Central

    Norton, Luke A.; Manger, Paul R.; Rubidge, Bruce S.

    2017-01-01

    Euchambersia mirabilis is an iconic species of Permo-Triassic therapsid because of its unusually large external maxillary fossa linked through a sulcus to a ridged canine. This anatomy led to the commonly accepted conclusion that the large fossa accommodated a venom gland. However, this hypothesis remains untested so far. Here, we conducted a μCT scan assisted reappraisal of the envenoming capacity of Euchambersia, with a special focus on the anatomy of the maxillary fossa and canines. This study shows that the fossa, presumably for the venom-producing gland, is directly linked to the maxillary canal, which carries the trigeminal nerve (responsible for the sensitivity of the face). The peculiar anatomy of the maxillary canal suggests important reorganisation in the somatosensory system and that a ganglion could possibly have been present in the maxillary fossa instead of a venom gland. Nevertheless, the venom gland hypothesis is still preferred since we describe, for the first time, the complete crown morphology of the incisiform teeth of Euchambersia, which strongly suggests that the complete dentition was ridged. Therefore Euchambersia manifests evidence of all characteristics of venomous animals: a venom gland (in the maxillary fossa), a mechanism to deliver the venom (the maxillary canal and/or the sulcus located ventrally to the fossa); and an apparatus with which to inflict a wound for venom delivery (the ridged dentition). PMID:28187210

  8. Orthodontic management of bilateral maxillary canine-first premolar transposition and bilateral agenesis of maxillary lateral incisors: a case report.

    PubMed

    Di Palma, Elena; Di Giuseppe, Biagio; Tepedino, Michele; Chimenti, Claudio

    2015-01-01

    Maxillary canine-first premolar transposition (Mx.C.P1) is an uncommon dental positional anomaly that may create many orthodontic problems from both esthetic and functional points of view. In this report we show the orthodontic management of a case of Mx.C.P1 associated with bilateral maxillary lateral incisor agenesis and unilateral mandibular second premolar agenesis The patient was treated with a multibracket appliance and the extraction of the lower premolar. treatment was completed without the need for any prosthetic replacement.

  9. Bilateral presence of two root canals in maxillary central incisors: A rare case study.

    PubMed

    Kavitha, M; Gokul, Kannan; Ramaprabha, B; Lakshmi, Amudha

    2014-04-01

    Success in root canal treatment is achieved after thorough cleaning and shaping followed by complete obturation of the canal system. Therefore, endodontic therapy requires specific and complete knowledge of the internal and external dental anatomy, and its variations in presentation. The internal anatomy of the maxillary central incisor is well-known and usually presents one root canal system. This case report describes an endodontic treatment of traumatized both maxillary central incisors with two canal systems. Knowledge of dental anatomy is fundamental for proper endodontic practice. When root canal treatment is performed, the clinician should be aware that both external and internal anatomy may be abnormal.

  10. Influences of age and maxillary anterior teeth status on patient's satisfaction with dental appearance and tooth colour.

    PubMed

    Lajnert, Vlatka; Pavičić, Daniela K; Gržić, Renata; Kovač, Zoran; Pahor, Dana; Kuis, Davor; Simonić-Kocijan, Sunčana; Antonić, Robert; Bakarčić, Danko

    2012-06-01

    To study the impact of age, gender, tooth colour and maxillary anterior teeth status on patient's satisfaction with their dental appearance. A total of 259 Caucasian subjects participated in the study (119 men, mean age 56 years; 140 women, mean age 61 years) divided into three age groups (young <35 age; middle aged 35-54 age; old ≥55 age). Their maxillary anterior teeth status was classified into three groups: (1) natural teeth (NTG) group; (2) composite filling group (CFG) and (3) porcelain-fused-to-metal fixed prosthodontic restoration group (FPDG). The participants judged appearance and tooth colour using a scale with three categories: completely dissatisfied, moderately dissatisfied and completely satisfied. Almost half of the participants were completely satisfied with their dental appearance and tooth colour. Half of the 'young' and 'middle-aged' participants with natural maxillary anterior teeth were completely satisfied and half of the 'old' participants were moderately satisfied with their dental appearance and tooth colour. The majority of participants with composite restorations (45-51%) were moderately satisfied with their dental appearance, one-third of 'young' and 'middle-aged' participants were moderately satisfied or dissatisfied with their tooth colour and more than 70% of older participants were dissatisfied with their tooth colour (p > 0.05). Satisfaction with the appearance of the maxillary anterior teeth differed both between individuals of different age and different dental status. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  11. The impact of complete denture making instructional videos on self-directed learning of clinical skills.

    PubMed

    Kon, Haruka; Botelho, Michael George; Bridges, Susan; Leung, Katherine Chiu Man

    2015-04-01

    The aim of this research was to evaluate the effectiveness of a clinical instructional video with a structured worksheet for independent self-study in a complete denture program. 47 multilingual dental students completed a task by watching an instructional video with subtitles regarding clinical complete denture procedures. After completion, students evaluated their learning experience, and 11 students participated in focus group interviews to gain further insight. A mixed-methods approach to data collection and analysis provided descriptive statistical results and a grounded theory approach to coding identified key concepts and categories from the qualitative data. Over 70% of students had favorable opinions of the learning experience and indicated that the speed and length of the video were appropriate. Highly positive and conflicting negative comments regarding the use of subtitles showed both preferences for subtitles over audio and vice versa. The use of a video resource was considered valuable as the replay and review functions allowed better visualization of the procedures, which was considered a good recap tool for the clinical demonstration. It was also a better revision aid than textbooks. So, if the students were able to view these videos at will, they believed that videos supplemented their self-study. Despite the positive response, videos were not considered to replace live clinical demonstrations. While students preferred live demonstrations over the clinical videos they did express a realization of these as a supplemental learning material for self-study based on their ease of access, use for revision, and prior to clinical preparation. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  12. Do CAD/CAM dentures really release less monomer than conventional dentures?

    PubMed

    Steinmassl, Patricia-Anca; Wiedemair, Verena; Huck, Christian; Klaunzer, Florian; Steinmassl, Otto; Grunert, Ingrid; Dumfahrt, Herbert

    2017-06-01

    Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.

  13. An in vitro study of the effect of different restorative materials on the reliability of a veneering porcelain.

    PubMed

    Anderson, Matthew R; Chung, Kwok-Hung; Flinn, Brian D; Raigrodski, Ariel J

    2013-12-01

    Implant-supported, porcelain veneered restorations experience a greater rate of porcelain fracture than tooth-supported restorations. For completely edentulous patients, one approach to minimizing porcelain fracture is to use acrylic resin in the mandible, although its efficacy is unknown. The purpose of this study was to evaluate the reliability of a veneering porcelain fatigued with different restorative materials in vitro. Fifty-nine veneering porcelain disk specimens were fabricated by layering veneering porcelain on nickel-chromium base metal alloy disks. Four groups of different indenter materials fatigued the porcelain specimens: group WC, tungsten carbide served as a control; group FC, pressed leucite glass ceramic; group NHC, nanohybrid composite resin denture tooth; and group AR, unfilled acrylic resin denture tooth. Porcelain specimens were randomly divided into 4 groups (n=14). A step-stress accelerated life-testing model was used. Use-level probability Weibull plots were generated, and the reliability of each group was estimated for a theoretical completion of 50 000 cycles at 150 N. Nanohybrid composite resin and unfilled acrylic resin denture tooth groups had higher reliability than tungsten carbide and leucite glass ceramic groups. No significant differences existed between the reliability of the tungsten carbide and leucite glass ceramic groups and the nanohybrid composite resin and acrylic resin denture tooth groups. Veneering porcelain disk specimens fatigued with the unfilled acrylic resin and nanohybrid composite resin denture tooth indenters exhibited higher reliability than the specimens fatigued with either the tungsten carbide or leucite glass ceramic indenters. All of the veneering porcelain disk specimens failed with the same mode of fracture, although the surface posttest exhibited different fracture characteristics among specimens fatigued with the 4 different materials. Copyright © 2013 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  14. Oral mark in the application of an individual identification: From ashes to truth.

    PubMed

    Chugh, Anshul; Narwal, Anumeha

    2017-01-01

    Forensic odontology is the branch of dentistry which deals with the proper handling, examination, evaluation and presentation of dental findings in the interest of justice. After major disasters and perimortem assaults such as earthquakes, fires, severe head and neck trauma or gross decomposition, accurate and early identification of dead and injured becomes important. In the absence of other records in such cases, identification is based on restorations, missing teeth and prosthetic devices such as partial and complete removable/fixed prosthesis or implant retained devices. This brings out the major role of prosthodontics to investigate the identity of suspects in the criminal cases as well as the deceased human beings in traumatic injuries or in disasters. Denture identification systems are being used as means of postmortem identification of edentulous persons which has evolved from the inclusion of some form of printed label in a denture to more high-tech methods. The provision of implant retained complete lower denture, antemortem, and postmortem radiographs of edentulous persons and correlation of bite marks using special impression techniques provide another potential source of evidence for human identification. Hence, this literature review throws some light on the role played by prosthodontist in forensic odontology.

  15. Masticatory muscle activity assessment and reliability of a portable electromyographic instrument.

    PubMed

    Bowley, J F; Marx, D B

    2001-03-01

    Masticatory muscle hyperactivity is thought to produce muscle pain and tension headaches and can cause excessive wear or breakage of restorative dental materials used in the treatment of prosthodontic patients. The quantification and identification of this type of activity is an important consideration in the preoperative diagnosis and treatment planning phase of prosthodontic care. This study investigated the quantification process in complete denture/overdenture patients with natural mandibular tooth abutments and explored the reliability of instrumentation used to assess this parafunctional activity. The nocturnal EMG activity in asymptomatic complete denture/overdenture subjects was assessed with and without prostheses worn during sleep. Because of the large variance within and between subjects, the investigators evaluated the reliability of the 3 instruments used to test nocturnal EMG activity in the sample. Electromyographic activity data of denture/overdenture subjects revealed no differences between prostheses worn versus not worn during sleep but demonstrated a very large variance factor. Further investigation of the instrumentation demonstrated a consistent in vitro as well as in vivo reliability in controlled laboratory studies. The portable EMG instrumentation used in this study revealed a large, uncontrollable variance factor within and between subjects that greatly complicated the diagnosis of parafunctional activity in prosthodontic patients.

  16. Precision of Fit of Titanium and Cast Implant Frameworks Using a New Matching Formula

    PubMed Central

    Sierraalta, Marianella; Vivas, Jose L.; Razzoog, Michael E.; Wang, Rui-Feng

    2012-01-01

    Statement of the Problem. Fit of prosthodontic frameworks is linked to the lifetime survival of dental implants and maintenance of surrounding bone. Purpose. The purpose of this study was to evaluate and compare the precision of fit of milled one-piece Titanium fixed complete denture frameworks to that of conventional cast frameworks. Material and Methods. Fifteen casts fabricated from a single edentulous CAD/CAM surgical guide were separated in two groups and resin patterns simulating the framework for a fixed complete denture developed. Five casts were sent to dental laboratories to invest, cast in a Palladium-Gold alloy and fit the framework. Ten casts had the resin pattern scanned for fabrication of milled bars in Titanium. Using measuring software, positions of implant replicas in the definitive model were recorded. The three dimensional spatial orientation of each implant replica was matched to the implant replica. Results. Results demonstrated the mean vertical gap of the Cast framework was 0.021 (+0.004) mm and 0.012 (0.002) mm determined by fixed and unfixed best-fit matching coordinate system. For Titanium frameworks they were 0.0037 (+0.0028) mm and 0.0024 (+0.0005) mm, respectively. Conclusions. Milled one-piece Titanium fixed complete denture frameworks provided a more accurate precision of fit then traditional cast frameworks. PMID:22550486

  17. The influence of verification jig on framework fit for nonsegmented fixed implant-supported complete denture.

    PubMed

    Ercoli, Carlo; Geminiani, Alessandro; Feng, Changyong; Lee, Heeje

    2012-05-01

    The purpose of this retrospective study was to assess if there was a difference in the likelihood of achieving passive fit when an implant-supported full-arch prosthesis framework is fabricated with or without the aid of a verification jig. This investigation was approved by the University of Rochester Research Subject Review Board (protocol #RSRB00038482). Thirty edentulous patients, 49 to 73 years old (mean 61 years old), rehabilitated with a nonsegmented fixed implant-supported complete denture were included in the study. During the restorative process, final impressions were made using the pickup impression technique and elastomeric impression materials. For 16 patients, a verification jig was made (group J), while for the remaining 14 patients, a verification jig was not used (group NJ) and the framework was fabricated directly on the master cast. During the framework try-in appointment, the fit was assessed by clinical (Sheffield test) and radiographic inspection and recorded as passive or nonpassive. When a verification jig was used (group J, n = 16), all frameworks exhibited clinically passive fit, while when a verification jig was not used (group NJ, n = 14), only two frameworks fit. This difference was statistically significant (p < .001). Within the limitations of this retrospective study, the fabrication of a verification jig ensured clinically passive fit of metal frameworks in nonsegmented fixed implant-supported complete denture. © 2011 Wiley Periodicals, Inc.

  18. Telescopic overdenture for oral rehabilitation of ectodermal dysplasia patient.

    PubMed

    Gupta, Charu; Verma, Mahesh; Gupta, Rekha; Gill, Shubhra

    2015-09-01

    Reduced number of teeth with underdeveloped alveolar ridges poses a greatest prosthetic challenge in rehabilitation of ectodermal dysplasia patients (ED). Furthermore, surgical risks and financial constraints may preclude the implant supported prosthesis, the most desirable treatment option in an adult ED patient. Long edentulous span does not permit fixed dental prosthesis (FDP) as well. Telescopic denture by incorporating the best of both fixed and removable prosthesis can be a viable treatment alternative for ED patients with compromised dentition and limited finances. A 21-year-old young girl presented with chief complaint of esthetics and mastication due to missing upper and lower teeth. A provisional diagnosis of ED was made based on familial history, physical, and oral examination. This clinical report describes management of an adult ED patient by means of telescopic overdenture prosthesis in mandibular arch and FDP in maxillary arch which restored esthetics, function, and social confidence of the patient in a cost effective manner.

  19. Telescopic overdenture for oral rehabilitation of ectodermal dysplasia patient

    PubMed Central

    Gupta, Charu; Verma, Mahesh; Gupta, Rekha; Gill, Shubhra

    2015-01-01

    Reduced number of teeth with underdeveloped alveolar ridges poses a greatest prosthetic challenge in rehabilitation of ectodermal dysplasia patients (ED). Furthermore, surgical risks and financial constraints may preclude the implant supported prosthesis, the most desirable treatment option in an adult ED patient. Long edentulous span does not permit fixed dental prosthesis (FDP) as well. Telescopic denture by incorporating the best of both fixed and removable prosthesis can be a viable treatment alternative for ED patients with compromised dentition and limited finances. A 21-year-old young girl presented with chief complaint of esthetics and mastication due to missing upper and lower teeth. A provisional diagnosis of ED was made based on familial history, physical, and oral examination. This clinical report describes management of an adult ED patient by means of telescopic overdenture prosthesis in mandibular arch and FDP in maxillary arch which restored esthetics, function, and social confidence of the patient in a cost effective manner. PMID:26604583

  20. CAD/CAM produces dentures with improved fit.

    PubMed

    Steinmassl, Otto; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca

    2018-02-22

    Resin polymerisation shrinkage reduces the congruence of the denture base with denture-bearing tissues and thereby decreases the retention of conventionally fabricated dentures. CAD/CAM denture manufacturing is a subtractive process, and polymerisation shrinkage is not an issue anymore. Therefore, CAD/CAM dentures are assumed to show a higher denture base congruence than conventionally fabricated dentures. It has been the aim of this study to test this hypothesis. CAD/CAM dentures provided by four different manufacturers (AvaDent, Merz Dental, Whole You, Wieland/Ivoclar) were generated from ten different master casts. Ten conventional dentures (pack and press, long-term heat polymerisation) made from the same master casts served as control group. The master casts and all denture bases were scanned and matched digitally. The absolute incongruences were measured using a 2-mm mesh. Conventionally fabricated dentures showed a mean deviation of 0.105 mm, SD = 0.019 from the master cast. All CAD/CAM dentures showed lower mean incongruences. From all CAD/CAM dentures, AvaDent Digital Dentures showed the highest congruence with the master cast surface with a mean deviation of 0.058 mm, SD = 0.005. Wieland Digital Dentures showed a mean deviation of 0.068 mm, SD = 0.005, Whole You Nexteeth prostheses showed a mean deviation of 0.074 mm, SD = 0.011 and Baltic Denture System prostheses showed a mean deviation of 0.086 mm, SD = 0.012. CAD/CAM produces dentures with better fit than conventional dentures. The present study explains the clinically observed enhanced retention and lower traumatic ulcer-frequency in CAD/CAM dentures.

  1. Stresses in Implant-Supported Fixed Complete Dentures with Different Screw-Tightening Sequences and Torque Application Modes.

    PubMed

    Barcellos, Leonardo H; Palmeiro, Marina Lobato; Naconecy, Marcos M; Geremia, Tomás; Cervieri, André; Shinkai, Rosemary S

    2018-05-17

    To compare the effects of different screw-tightening sequences and torque applications on stresses in implant-supported fixed complete dentures supported by five abutments. Strain gauges fixed to the abutments were used to test the sequences 2-4-3-1-5; 1-2-3-4-5; 3-2-4-1-5; and 2-5-4-1-3 with direct 10-Ncm torque or progressive torque (5 + 10 Ncm). Data were analyzed using analysis of variance and standardized effect size. No effects of tightening sequence or torque application were found except for the sequence 3-2-4-1-5 and some small to moderate effect sizes. Screw-tightening sequences and torque application modes have only a marginal effect on residual stresses.

  2. Miscellaneous Burial Recovery in Eastern Washington, 1981.

    DTIC Science & Technology

    1983-01-01

    jaws. Specifically, an abscess associated with the maxillary left first premolar was present. The maxillary alveolar structures also exhibited...completely resorbed — evidence of periodontal disease. The general condition of the teeth and the periodontal bone suggests an old individual who

  3. Comparison of chewing ability, oral health related quality of life and nutritional status before and after insertion of complete denture amongst edentulous patients in a Dental College of Pune.

    PubMed

    Madhuri, Sonawane; Hegde, Shetiya Sahana; Ravi, Shirahatti; Deepti, Agarwal; Simpy, Mahuli

    2014-07-01

    The relationship between tooth loss and nutritional intake is important. As people age, their diminished physical capacity and decreased income adversely affect their ability to maintain their teeth. The aim of the study was to assess and compare the chewing ability, oral health related quality of life and nutritional status before and after fabrication and insertion of complete denture amongst edentulous participants in a dental college. Non Randomized Intervention study. The study population consisted of 42 participants (16 females and 26 males), aged 50 years and above. Prior to commencement of the study, informed consent was obtained and validation and reliability test of the questionnaire were done. The data for chewing ability, GOHAI and nutritional status assessment was recorded at baseline, 3(rd), 6(th) and 12(th) month after denture fabrication and insertion. The statistical comparisons were performed by repeated measure ANOVA and Chi-square test. P value<0.05 was considered as statistically significant. Chewing ability, GOHAI, BMI (Body Mass Index) and data from Food-intake questionnaire showed statistically significant improvement from baseline to 6(th) month but no statistically significant improvement was observed from 6(th) month to 12(th) month. Nutritive value of food (protein, energy and fat) showed no significant difference over a period of 12 months (p<0.05). Thus, it was concluded that the intervention (denture insertion) was effective in increasing the chewing ability, body weight, food-intake, and oral health related quality of life.

  4. [Quantitative evaluation of fabricating complete denture by computer numerical control in manufacturing dentition and baseplate separately plus adhesive molding].

    PubMed

    Wang, H; Lv, P J; Wang, Y; Sun, Y C

    2016-10-18

    To quantitatively evaluate the assembly precision of fabricating complete denture by computer numerical control (CNC) in manufacturing dentition and baseplate separately plus adhesive molding. The 3D surface data of a standard edentulous maxilla plaster cast model and the temporary base-plate were obtained using an Activity 880 3D scanner. The data (data1) of a complete denture were designed using a set of computer aided design (CAD) software developed by the research group of this study. The pins without undercut were designed as 3D shape of the joining area of the dentition and the baseplate by using the software of Imageware 13.2 and Geomagic Studio 2013. Zero in the top and 0.05 mm in the rest surfaces of the retention pins were set for adhesive clearance. Zenotec T1 (5-axis milling machine) was employed to manufacture polymethyl methacrylate (PMMA) dentition and baseplate. Double sides posterior and one anterior "union teeth" were got. The teeth were inserted into the retention pins in the baseplate and cemented with self-curing resin (Huge Dental Material Co., Ltd). The denture was scanned with the 3D scanner to obtain dataset Data4. Data2 and Data3 registration was set in Data4, Data2 and Data3 were united to gain Data 5. The adhesive clearance on the top of the retentional pins was measured, which was originally designed into 0 mm, and the assembly precision of dentition and baseplate obtained. The average clearance measurements between the dentition and the baseplate: left molar teeth (0.44±0.04) mm, max 0.52 mm, min 0.29 mm; right molar teeth (0.52±0.07) mm, max 0.64 mm, min 0.28 mm; anterior teeth (0.60±0.10) mm, max 0.81 mm, min 0.40 mm; total average clearance (0.52±0.10) mm. The adhesive clearance can be controlled to the level of 0.5 mm when the joining part of the artificial teeth and the base was designed into the shape of retentional pins and the artificial dentition divided into 3 parts. We succeeded in using the CAD/ computer aided manufacturing (CAM) technology to fabricate the complete denture. Although the assembly precision of the dentition and the baseplate is not perfect, the results have proved that the technical routes are workable.

  5. OHRQoL, masticatory performance and crestal bone loss with single-implant, magnet-retained mandibular overdentures with conventional and shortened dental arch.

    PubMed

    Grover, Manita; Vaidyanathan, Anand Kumar; Veeravalli, Padmanabhan Thallam

    2014-05-01

    The aim of this study was to assess the use of single implant-supported, magnet-retained mandibular overdentures to improve the oral health-related quality of life (OHRQoL) and masticatory performance of patients wearing conventional complete dentures. The study also aimed at comparing the OHRQoL, masticatory performance, and crestal bone loss with two different types of overdenture prosthesis. Ten completely edentulous patients with atrophic mandibular residual alveolar ridges and having difficulty coping with technically adequate mandibular dentures were selected for implant-supported overdentures (ISOD). To assess the success of the implant fixture clinically, a crossover study design was followed, and the patients were divided into two groups. Group A received ISOD with conventional complete dental arch, and group B received ISOD with a shortened dental arch for the first 3 months and vice versa for the next 3 months. The OHRQoL was measured with the OHIP-49 questionnaire, and masticatory performance was assessed with the sieve method using peanuts as test food. Peri-apical radiographs were taken to evaluate the crestal bone loss. A significant improvement was seen both subjectively and objectively when conventional complete dentures were modified to implant-supported prosthesis. When comparing the implant overdenture prosthesis, patients were more satisfied with conventional arch than with the shortened dental arch. In the first 3 months following implant placement, less bone loss was seen with the shortened dental arch overdenture (P < 0.05). Single implant-supported, magnet-retained mandibular overdentures significantly improve the OHRQoL of completely edentulous patients. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  6. An evaluation of the position of the neutral zone in relation to the crest of mandibular alveolar ridge - An In-vivo study

    PubMed Central

    Bhorgonde, Deepak; Nandakumar, K; Khurana, Punit R S; Kumari, V Santoshi; Reddy, M Sushendar; Siddique, Sabin

    2014-01-01

    Background: In view of the importance of neutral zone in complete denture construction, it was thought feasible to determine the relation between the centre of the alveolar ridge crest in relation to the neutral zone in a buccolingual direction which will help in positioning of the teeth in a region of minimum conflict so that the stability of the denture is enhanced. Materials & Methods: The position of the neutral zone to alveolar ridge crest was investigated in 30 edentulous patients comprising of both males and females divided into three groups, Group I consisted of ten patients whose period of edentulousness varied from 0-4 years. Group II included ten patients who were edentulous for more than 4 years but less than 8 years. Group III consisted of ten patients whose period of edentulousness varied between 8-12 years. One-way ANOVA test and multiple comparisons by bonferroni post-hoc tests were used to analyze the results and the significance was tabulated. Results: The results of the present study state that the neutral zone serves as a guide and suggests that the period of edentulousness should be considered while arranging the teeth for complete dentures. Conclusion: The findings of the current study may serve as an important guide in arrangement of teeth for complete denture prosthesis and would help to determine the correlation between the neutral zone in relation to the crest of the alveolar ridge and the period of edentulousness. How to cite the article: Bhorgonde D, Nandakumar K, Khurana PR, Kumari VS, Reddy MS, Siddique S. An evaluation of the position of the neutral zone in relation to the crest of mandibular alveolar ridge - An In-vivo study. J Int Oral Health 2014;6(2):45-54. PMID:24876702

  7. Impact of removable dentures on oral health-related quality of life among elderly adults in Taiwan.

    PubMed

    Yen, Yea-Yin; Lee, Huey-Er; Wu, Yi-Min; Lan, Shou-Jen; Wang, Wen-Chen; Du, Je-Kang; Huang, Shun-Te; Hsu, Kun-Jung

    2015-01-05

    Although the use of removable dentures can improve oral function and esthetics for elderly people, compared to those who do not wear removable dentures, those wearing removable dentures could have worse oral health related-quality of life (OHRQoL). Additional information is required to assess which factors related to denture wearing influence the OHRQoL of elderly individuals. The purpose of this study is to evaluate the association between denture wearing and OHRQoL in a sample of elderly individuals in Taiwan. The study population included 277 elderly people wearing removable dentures (mean age = 76.0 years). Using face-to-face interviews, we collected data on the participants' socio-demographic characteristics, dental care service usage (regular dental checkups, treatment during toothache, dental visits in the last year), and factors related to denture wearing (perceived oral pain, perceived loose denture, perceived oral ulcer, perceived halitosis, perceived dry mouth, and perceived total denture satisfaction scores). OHRQoL was measured using the Taiwanese version of the Geriatric Oral Health Assessment Index (GOHAI-T). The location and number of remaining natural teeth and the type of denture were also recorded. Hierarchical multiple regression analysis was performed using GOHAI-T scores as the dependent variable. All the predictors together accounted for 50% of the variance in GOHAI-T scores. Further, education level, number of natural teeth, denture status, perceived loose denture, perceived oral ulcer, and perceived total denture satisfaction scores had statistically significant influences on OHRQoL. When compared with other variables, factors related to denture wearing, especially perceived total denture satisfaction scores, had the greatest impact on GOHAI-T scores. Of the factors analyzed in this study, denture satisfaction was the strongest predictor of OHRQoL. This suggests that denture satisfaction is useful for assessing the effect of denture treatment on the OHRQoL of elderly individuals wearing removable dentures.

  8. Distraction osteogenesis versus orthognathic surgery for the treatment of maxillary hypoplasia in cleft lip and palate patients: a systematic review.

    PubMed

    Austin, S L; Mattick, C R; Waterhouse, P J

    2015-05-01

    To compare the effectiveness of distraction osteogenesis to orthognathic surgery for the treatment of maxillary hypoplasia in individuals with cleft lip and palate. A systematic review of prospective randomized, quasi-randomized or controlled clinical trials. MEDLINE, EMBASE, Scopus, Web of Science, CINAHL, CENTRAL, trial registers and grey literature were searched. Hand searching of five relevant journals was completed. Two reviewers independently completed inclusion assessment. Data extraction and risk of bias assessment were completed by a single reviewer and checked by a second reviewer. Five publications all reporting different outcomes of a single randomized controlled trial are included within the review. The quality of the evidence was low with a high risk of bias. Both surgical interventions produce significant soft tissue improvement. Horizontal relapse of the maxilla was statistically significantly greater following orthognathic surgery. There was no statistically significant difference in speech and velo-pharyngeal function between the interventions. Maxillary distraction initially lowered social self-esteem, but this improved with time resulting in higher satisfaction with life in the long term. The low quality of evidence included within the review means there is insufficient evidence to conclude whether there is a difference in effectiveness between maxillary distraction and osteotomy for the treatment of cleft-related maxillary hypoplasia. There is a need for further high-quality randomized controlled trials to allow conclusive recommendations to be made. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Dental health professional recommendation and consumer habits in denture cleansing.

    PubMed

    Axe, Alyson S; Varghese, Roshan; Bosma, MaryLynn; Kitson, Nicola; Bradshaw, David J

    2016-02-01

    Regular cleaning of dentures is essential to the oral and general health of denture wearers. Only limited systematic data are available on the recommendations that dental health care professionals (DHCPs) make to patients for denture cleaning. Data on denture wearers' cleaning regimens are also lacking. The purpose of this study was to provide data on recommendations that DHCPs make to patients for denture cleaning and on the cleaning regimens of denture wearers. DHCPs (n=613), including dentists and hygienists, were surveyed in developed (Japan, USA, Italy) and developing (Brazil, India) countries. A questionnaire assessing a range of denture cleaning recommendations was used. The questions addressed products, frequency, how to use remedies, the suggested dilution and duration of cleansing treatment, the location of dentures while cleaning, and the reasoning behind the recommendation of particular products or modes of treatment. Denture cleansing methods and the routine of denture wearers in developed and developing countries were also surveyed with a questionnaire (n=2862) and a 1-week diary (n=1462). An average of more than 2 treatments was recommended by DHCPs. Specialist denture cleanser tablets, "regular" toothpaste, mouthwash, soap and water, denture paste, foam or liquid denture cleanser, and dishwashing detergents were most commonly recommended; other product recommendations included baking soda, vinegar, salt water, and bleach. More than 10% of DHCPs made no primary recommendation on cleaning. Denture tablets were more commonly recommended in developed countries, whereas toothpaste was the most common recommendation in developing countries. Denture wearers used products and methods similar to those recommended by DHCPs. Toothpaste, water, and mouthwash were used more frequently than denture tablets. More than 75% of denture wearers reported using denture cleanser tablets for more than 5 minutes, whereas soap and toothpaste were typically used for less than 2 minutes. DHCP recommendations and denture wearer habits are diverse, with no consensus on the most appropriate denture cleaning methods. This reflects a lack of clear, systematic evidence upon which to base recommendations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  10. ELECTROMYOGRAPHIC EVALUATION OF MASTICATION AND SWALLOWING IN ELDERLY INDIVIDUALS WITH MANDIBULAR FIXED IMPLANTSUPPORTED PROSTHESES

    PubMed Central

    Berretin-Felix, Giédre; Nary, Hugo; Padovani, Carlos Roberto; Trindade, Alceu Sergio; Machado, Wellington Monteiro

    2008-01-01

    This study evaluated the effect of implant-supported oral rehabilitation in the mandible on the electromyographic activity during mastication and swallowing in edentulous elderly individuals. Fifteen patients aged more than 60 years were evaluated, being 10 females and 5 males. All patients were edentulous, wore removable complete dentures on both dental arches, and had the mandibular dentures replaced by implant-supported prostheses. All patients were submitted to electromyographic evaluation of the masseter, superior orbicularis oris muscles, and the submental muscles, before surgery and 3, 6 and 18 months postoperatively, using foods of different textures. The results obtained at the different periods were analyzed statistically by Kruskal-Wallis non-parametric test. Statistical analysis showed that only the masseter muscle had a significant loss in electromyographic activity (p<0.001), with a tendency of similar response for the submental muscles. Moreover, there was an increase in the activity of the orbicularis oris muscle during rubber chewing after treatment, yet without statistically significant difference. Mandibular fixed implant-supported prostheses in elderly individuals revealed a decrease in electromyographic amplitude for the masseter muscles during swallowing, which may indicate adaptation to new conditions of stability provided by fixation of the complete denture in the mandibular arch. PMID:19089202

  11. Evaluation of oral stereognostic ability after rehabilitating patients with complete dentures: in vivo study.

    PubMed

    Meenakshi, S; Gujjari, Anil Kumar; Thippeswamy, H N; Raghunath, N

    2014-12-01

    Stereognosis has been defined as the appreciation of the form of objects by palpation. Whilst this definition holds good for the manual exploration of objects, it is possible for the shape of objects to be explored intra orally referred to as oral stereognosis. To better understand patients' relative satisfaction with complete dentures, differences in oral stereognostic perception, based on the identification of 6 edible objects was analyzed in a group of 30 edentulous individuals at 3 stages, namely, just before (pre-treatment), 30 min after (30 min post-treatment) and 1 month after (1 month post-treatment) the insertion of new dentures. The time required to identify each object was recorded and the correctness of identification of each object was scored using oral stereognostic score. Descriptive statistics, Wilcoxon signed rank test, Spearman's rank correlation test, Pearson Chi square test was used to statistically analyze the data obtained. OSA scores was significantly increased 1 month post-treatment compared to 30 min post-treatment (p < 0.05). It was found that Oral stereognostic test is reliable for measuring patients' oral stereognostic perception and may be used as one of the clinical aids in appreciating the functional limitations imposed by the prostheses.

  12. 21 CFR 872.3165 - Precision attachment.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... conjunction with removable partial dentures. Various forms of the device are intended to connect a lower partial denture with another lower partial denture, to connect an upper partial denture with another upper partial denture, to connect either an upper or lower partial denture to a tooth or a crown, or to connect...

  13. Denture plaque--past and recent concerns.

    PubMed

    Nikawa, H; Hamada, T; Yamamoto, T

    1998-05-01

    This paper critically reviews the history of denture plaque and identifies some concerns with the presence of Candida in the mouth. This review covers literature sources related to Candida albicans and its relationship to denture plaque. The articles selected for this review are from referred journals and describe C. albicans and its relationship to oral, gastrointestinal and pleuropulmonary infections. The relationship to caries, root caries and periodontal disease is also covered. Denture plaque containing Candida could cause not only oral candidiasis, like oral thrush or denture-induced stomatitis, but also caries, root caries and periodontitis of abutment teeth. However, there is only limited experimental evidence or information available on the cariogenicity of Candida. The continuous swallowing or aspiration of micro-organisms from denture plaque exposes patients, particularly the immunocompromised host or medicated elderly, to the risks of unexpected infections. The term, 'denture plaque' has been used throughout the review. However, the term 'plaque on denture' should be used because the microbial flora and its pathogenicity of denture plaque resembles those of plaque formed on the tooth surface, so called dental plaque. In addition, the term 'denture related stomatitis' would be preferable to 'denture induced stomatitis', since the inflammation of (palatal) mucosa is not induced by the denture, but by wearing the denture or by plaque on the denture.

  14. Accelerating effects of cellulase in the removal of denture adhesives from acrylic denture bases.

    PubMed

    Harada-Hada, Kae; Mimura, Sumiyo; Hong, Guang; Hashida, Tatsumi; Abekura, Hitoshi; Murata, Hiroshi; Nishimura, Masahiro; Nikawa, Hiroki

    2017-04-01

    Studies of effective methods for the easy removal of denture adhesives from a denture base are not well represented in the literature. We previously assessed the removability of denture adhesives by immersing within denture cleaners, showing that some cleaners have a weak effect, insufficiently effective in daily use. In this study, we prepared a cellulase, as a potential component for denture adhesive removers, and we examined whether the addition of cellulase to denture cleaners is effective in the removal of cream denture adhesives. We prepared the cellulase Meicelase as one component for the liquefaction of denture adhesives. We used two denture cleaners and two cream adhesives. After the immersion of plates in sample solutions, we evaluated the area of the sample plate still covered with adhesives. Biofilm removal assay was also performed using denture cleaners containing cellulase. The addition of cellulase accelerated the removal of cream adhesives in immersion experiments to a rate faster than that of water and denture cleaners. However, it did not influence the removability of Candida albicans biofilms from acrylic resin specimens. Cellulase hastened the liquefaction of cream adhesives. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  15. Influence of denture surface roughness and host factors on dental calculi formation on dentures: a cross-sectional study.

    PubMed

    Matsumura, Keisuke; Sato, Yuji; Kitagawa, Noboru; Shichita, Toshiharu; Kawata, Daisuke; Ishikawa, Mariko

    2018-05-04

    Dental calculi formation on dentures can worsen the oral cavity environment by complicating oral hygiene. However, few studies have investigated the effect of how patients use and manage their dentures, denture surface roughness, and host factors such as oral cavity dryness and saliva properties on denture cleanliness and denture dental calculi formation. Accordingly, we conducted the present survey to evaluate these factors to clarify the strength of the influence of each factor. We enrolled 53 patients who had used dentures for at least 3 months and used a dental prosthesis that covered at least the six front teeth including the left and right mandibular canines. After staining the dentures, we divided the participants into a group that was positive for dental calculi (DCP group) and a group that was negative for dental calculi (DCN group). After removing all the stains, we evaluated the surface roughness of the dentures. A questionnaire was used to survey how the participants used and managed their dentures. Oral cavity dryness was evaluated, and resting saliva samples were collected to assess saliva properties. Correlations between the presence or absence of dental calculi and denture use and management were evaluated using a chi-square test. Correlations with denture surface roughness, oral cavity dryness, and saliva properties were evaluated using the Mann-Whitney U test. Correlations between the presence or absence of dental calculi and all factors were analyzed using multivariate analysis (quantification II). Surface roughness was significantly greater in the DCP group (p < 0.01), and the DCP group members wore their dentures during sleep significantly more often and used a denture cleaner when storing their dentures significantly less often (both p < 0.01). No significant differences were observed for oral cavity dryness or saliva properties. The multivariate analysis showed significant correlations of dental calculi formation with denture surface roughness and items related to denture use and management, but not for oral cavity dryness or saliva properties. Our findings indicate that dental calculi formation is influenced by how dentures are used and managed and by denture surface roughness, but not by oral cavity dryness and saliva properties.

  16. Correction of complete maxillary crossbite with severe crowding using Hyrax expansion and fixed appliance.

    PubMed

    Wangsrimongkol, Tasanee; Manosudprasit, Montian; Pisek, Poonsak; Leelasinjaroen, Pornnapha

    2013-09-01

    An 18-year-old Thai man who presented with a secondary cleft palate, maxillary hypoplasia and severe crowding was treated by rapid maxillary expansion and fixed orthodontic appliances. Initial assessment found skeletal Class III malrelationship and dental Class II malocclusion with anterior and bilateral posterior crossbites. Camouflage orthodontic treatment was planned using a rapid maxillary expansion appliance and correcting crowding with extraction all four premolar teeth. A Hyrax appliance and vertical loop arch wire were placed for maxillary arch expansion of 9.5 mms at first molars and canines, and 5.5 mms at the premolars and obtained positive overjet. Both acceptable skeletal and soft tissue relationships and satisfactory occlusion were produced. After 14 months of postoperative follow-up, the occlusal result was stable and no skeletal reversals could be detected.

  17. Quality of Life with Removable Dentures

    PubMed Central

    Hadzipasic-Nazdrajic, Amra

    2011-01-01

    Goal: To measure change in a quality of life after treatment with removable dentures and to describe differences in quality of life in patients with new and worn out dentures. Materials and methods: Measuring instrument was OHIP-49, translated from English into one of the languages in Bosnia-Herzegovina. Sample consisted of patients who wanted to make/replace mobile dentures or came to repair a broken dentures. Comprehensibility of the OHIP-BH49 was tested on a sub-sample of patients. Three measurements were made: before and after the insertion of dentu res and when patients came to repair their mobile dentures. Results: Sample consisted of 67 patients: 32 patients who sought prosthetic treatment, and 35 who came to repair their broken dentures. We received 89.7% correctly filled questionnaires. Minor changes were made in four (4) questions. Statistical analysis performed with the T-test revealed the significant differences, before and after the treatment with mobile dentures (t=39.5, p<0.001). There was a significant difference in OHIP scores in patients with a new dentures, compared to the patients who had worn out dentures (t=44.30, p<0.001). Substantial differences, between OHIP scores, regarding the time of wearing dentures or patients’ age were not observed. Discussion: Patients who wore dentures longer than 5 years, showed better quality of life, because they became accustomed to the dentures. Conclusions: Self-reported life quality improved considerably after insertion of a new dentures. Patients with a new dentures showed significantly better quality of life than patients with worn out dentures. One part of OHIP validation in Bosnia-Herzegovina has been done. PMID:23678299

  18. Clinical effectiveness of late maxillary protraction in cleft lip and palate: a methods paper

    PubMed Central

    Lee, MK; Lane, C; Azeredo, F; Landsberger, M; Kapadia, H; Sheller, B; Yen, SL

    2017-01-01

    Objectives A prospective parallel cohort trial was conducted to compare outcomes of patients treated with maxillary protraction vs. LeFort 1 maxillary advancement surgery. Setting and Sample Population The primary site for the clinical trial is Children’s Hospital Los Angeles; the satellite test site is Seattle Children’s Hospital. All patients have isolated cleft lip and palate and a skeletal Class III malocclusion. Material & Methods A total of 50 patients, ages 11–14 will be recruited for the maxillary protraction cohort. The maxillary surgery cohort consists of 50 patients, ages 16–21, who will undergo LeFort 1 maxillary advancement surgery. Patients with additional medical or cognitive handicaps were excluded from the study. Results Current recruitment of patients is on track to complete the study within the proposed recruitment period. Conclusion This observational trial is collecting information that will examine dental, skeletal, financial, and quality of life issues from both research cohorts. PMID:28643931

  19. Complications and patient-centered outcomes with an implant-supported monolithic zirconia fixed dental prosthesis: 1 year results.

    PubMed

    Limmer, Bryan; Sanders, Anne E; Reside, Glenn; Cooper, Lyndon F

    2014-06-01

    To characterize the number and type of complications that occur with a monolithic zirconia fixed dental prosthesis (MZ-FDP) supported by four endosseous implants in the edentulous mandible over time and to quantify the impact of treatment on oral health quality of life (OHQoL). Seventeen edentulous participants were enrolled. New conventional dentures were fabricated for each participant. Four Astra Tech Osseospeed TX implants (Dentsply) were then placed in the parasymphyseal mandible, and after a period of healing, a full-arch monolithic zirconia prosthesis (Zirkonzahn) was inserted. Complication data were recorded and OHQoL was evaluated using the Oral Health Impact Profile (OHIP-49), administered on four occasions: enrollment; implant surgery; and 6- and 12-month recalls. Sixty-eight implants were placed in 17 edentulous individuals aged 30 to 78 (mean 57.9 years). Implant survival was 94% from the subject perspective and 99% from the implant perspective. Prosthesis survival was 88%. Twelve complications occurred in ten participants, whereas seven participants remained complication free. Both OHIP-49 severity and extent scores decreased significantly between enrollment and 12-month recall (p < 0.001). The mean OHIP-49 severity score at baseline was 94.8 (95% confidence interval [CI]: 73.9, 115.8) and declined an average of 76.8 (95% CI: -91.3, -62.3) units per participant. The mean OHIP-49 extent score at baseline was 17.2 (95% CI: 10.8, 23.6) and declined 16.3 (95% CI: -20.2, -12.4) units per participant on average. Implant survival was high, and few complications related to the MZ-FDP were observed. The most common prosthetic complication was tooth chipping in the opposing maxillary denture, which accounted for 50% of all complication events. Substantial and clinically important improvements in OHQoL were achieved with both conventional dentures and the implant-supported MZ-FDP. The data of this short-term study indicate that the implant-supported MZ-FDP is a therapeutic option with particular advantages in the edentulous mandible that warrants further long-term study. © 2014 by the American College of Prosthodontists.

  20. Evolution of oral cancer treatment in an andalusian population sample: Rehabilitation with prosthetic obturation and removable partial prosthesis

    PubMed Central

    Flores-Ruiz, Rafael; Castellanos-Cosano, Lizette; Serrera-Figallo, María-Angeles; Gutiérrez-Corrales, Aida; Gonzalez-Martin, Maribel; Gutiérrez-Pérez, Jose-Luis

    2017-01-01

    Background Radical surgical resection as a treatment modality for oral cancer often leads to an extensive deficit in both the maxillary and mandibular levels, where the use of a palatal obturator prosthesis (POP) or removable partial denture (RPP). The aim of this study was to evaluate the treatment with POP and RPP in patients treated for oral cancer in the Unit of Prosthetic Rehabilitation of the University Hospital Virgen del Rocío in a period of 20 years. Material and Methods Retrospective descriptive study during the years 1991 and 2011 analyzing oral cancer type, characteristics, treatment and follow-up. The sample consisted of patients whose tumor had previously been removed and who had been referred to the Oncological Rehabilitation Unit of the Oral and Maxillofacial Surgery Unit of the “Virgen del Rocío” University Hospital for rehabilitation. The inclusion criteria were patients whose underlying pathology was any type of neoplasia, which after its treatment had been referred to the aforementioned Oncological Prosthetic Rehabilitation unit. Results Of the 45 patients included in our study, 15 patients were rehabilitated with palatal obturator (33.3%) and 5 patients with removable partial denture (11.1%). The mean age of the sample of patients with POP was 57.3 ± 9.23, while the mean age of the sample of patients with RPP was 58 ± 13.5. The most common underlying pathology in patients with POP was squamous cell carcinoma (60%), whereas in patients with RPP it was 100%. The most frequent location found among POP patients was the upper jaw, while in the PRP patients there was no predominant location. The univariate and multivariate logistic regressions did not show any statistically significant association between the independent variables age, sex, smoking habit and alcoholic habit with the dependent variable type of rehabilitating prosthesis. Conclusions Based on our data, we can conclude that RPP is used in few cases of oncological rehabilitation. The POP has a greater use, as long as the defect in the bones of the facial middle third is limited. Key words:Head and neck cancer, reconstructive surgery, Palatal obturators, removable partial dentures. PMID:28936292

  1. Evolution of oral cancer treatment in an andalusian population sample: Rehabilitation with prosthetic obturation and removable partial prosthesis.

    PubMed

    Flores-Ruiz, Rafael; Castellanos-Cosano, Lizette; Serrera-Figallo, María-Angeles; Gutiérrez-Corrales, Aida; Gonzalez-Martin, Maribel; Gutiérrez-Pérez, Jose-Luis; Torres-Lagares, Daniel

    2017-08-01

    Radical surgical resection as a treatment modality for oral cancer often leads to an extensive deficit in both the maxillary and mandibular levels, where the use of a palatal obturator prosthesis (POP) or removable partial denture (RPP). The aim of this study was to evaluate the treatment with POP and RPP in patients treated for oral cancer in the Unit of Prosthetic Rehabilitation of the University Hospital Virgen del Rocío in a period of 20 years. Retrospective descriptive study during the years 1991 and 2011 analyzing oral cancer type, characteristics, treatment and follow-up. The sample consisted of patients whose tumor had previously been removed and who had been referred to the Oncological Rehabilitation Unit of the Oral and Maxillofacial Surgery Unit of the "Virgen del Rocío" University Hospital for rehabilitation. The inclusion criteria were patients whose underlying pathology was any type of neoplasia, which after its treatment had been referred to the aforementioned Oncological Prosthetic Rehabilitation unit. Of the 45 patients included in our study, 15 patients were rehabilitated with palatal obturator (33.3%) and 5 patients with removable partial denture (11.1%). The mean age of the sample of patients with POP was 57.3 ± 9.23, while the mean age of the sample of patients with RPP was 58 ± 13.5. The most common underlying pathology in patients with POP was squamous cell carcinoma (60%), whereas in patients with RPP it was 100%. The most frequent location found among POP patients was the upper jaw, while in the PRP patients there was no predominant location. The univariate and multivariate logistic regressions did not show any statistically significant association between the independent variables age, sex, smoking habit and alcoholic habit with the dependent variable type of rehabilitating prosthesis. Based on our data, we can conclude that RPP is used in few cases of oncological rehabilitation. The POP has a greater use, as long as the defect in the bones of the facial middle third is limited. Key words: Head and neck cancer, reconstructive surgery, Palatal obturators, removable partial dentures.

  2. Periodontal therapy for severe chronic periodontitis with periodontal regeneration and different types of prosthesis.

    PubMed

    Kinumatsu, Takashi; Umehara, Kazuhiro; Nagano, Kyosuke; Saito, Atsushi

    2014-01-01

    We report a patient with severe chronic periodontitis requiring regenerative periodontal surgery and different types of prosthesis in the maxillary and mandibular regions. The patient was a 57-year-old woman who presented with the chief complaint of occlusal pain. An initial clinical examination revealed that 73% of sites had a probing depth of ≥4 mm, and 60% of sites exhibiting bleeding on probing. Radiographic examination revealed vertical bone defects in the molar region and widening of the periodontal ligament space around teeth #17 and 24. Initial periodontal therapy was implemented based on a clinical diagnosis of severe chronic periodontitis. Surgical periodontal therapy was subsequently performed at selected sites. Periodontal regenerative therapy using enamel matrix derivative was performed on #14, 15, and 35-37. Tunnel preparation was performed on #46 as it had a 2-wall vertical bony defect and Degree 3 furcation involvement. Other sites with residual periodontal pockets were treated by modified Widman flap surgery. After a re-evaluation, functional rehabilitation was implemented with a removable maxillary partial denture and a fixed mandibular bridge. No further deterioration was observed in the periodontal condition of most of the teeth during a 2-year period of supportive periodontal therapy (SPT). The patient is currently still undergoing SPT and some minor problems remain. However, the results suggest that treatment and subsequent maintenance for severe periodontitis with traumatic occlusion can be successful as long as the appropriate periodontal and prosthodontic treatment is planned and careful SPT carried out.

  3. Implant site development by orthodontic forced eruption of nontreatable teeth: a case report.

    PubMed

    Rokn, Amir Reza; Saffarpour, Anna; Sadrimanesh, Rouzbeh; Iranparvar, Kaveh; Saffarpour, Aida; Mahmoudzadeh, Majid; Soolari, Ahmad

    2012-01-01

    Loss of bone and soft tissue attachment are common sequelae of periodontitis that may jeopardize the aesthetic outcome and compromise the functional and aesthetic outcomes of treatment. The following case report describes one of the most predictable techniques of vertical ridge augmentation, which is orthodontic extrusion or forced eruption of hopeless teeth. A 34-year-old woman who presented with severe attachment loss and deep pockets was diagnosed with generalized aggressive periodontitis. The mobile maxillary incisors were consequently extracted and were replaced with dental implants. However, prior to extraction, orthodontic extrusion of the hopeless incisors was performed to correct vertical ridge defects. Following extrusion and extraction of the maxillary incisors, to prevent soft tissue collapse and to preserve the papillae during socket healing, the crowns of the extracted teeth were used as pontics on a removable partial provisional denture. After 8 weeks, the implants were placed, and an immediate functional restoration was delivered. After 4 months of healing, a fixed definitive partial prosthesis was fabricated and delivered. After periodontal treatment, over a 2-year period, the progression of aggressive periodontitis was controlled. The mean vertical movement of marginal bone was 3.6 mm. The use of the crowns of extracted teeth appears to be an effective method to maintain papillae. Orthodontic extrusion is a predictable method for the correction of vertical ridge defects. Orthodontic treatment does not aggravate or hasten the progression of aggressive periodontitis.

  4. A new palatal distractor device for bodily movement of maxillary bones by rigid self-locking miniplates and screws system.

    PubMed

    Cortese, Antonio; Savastano, Mauro; Cantone, Antonio; Claudio, Pier Paolo

    2013-07-01

    A new palatal distractor device for bodily movement of the maxillary bones after complete segmented Le Fort I osteotomy for 1-stage transversal distraction and tridimensional repositioning on 1 patient is presented. The new distractor has an intrinsic tridimensional rigidity also in the fixation system by self-locking miniplates and screws for better control of the 2 maxillary fragments during distraction. Le Fort I distraction and repositioning procedure in association with a bilateral sagittal split osteotomy were performed on 1 patient with complete solution of the cross-bite and class III malocclusion. Results of dental and cephalometric analysis performed before surgery (T1), after surgery and distraction time (T2), and 18 months after surgery and orthodontic appliance removal (T3) are reported. No complications were encountered using the new distractor device. Advantages of this device and technique are presented including improved rigidity of both distraction (jackscrew) and fixation (4 self-locking miniplates and screws) systems resulting in complete control of the position of the 2 maxillary fragments during distraction and surgery. In addition, this new device allows resuming palatal distraction in the event of cross-bite relapse without causing dental-related problems or the risks of screw slackening.

  5. Implant and root supported overdentures - a literature review and some data on bone loss in edentulous jaws.

    PubMed

    Carlsson, Gunnar E

    2014-08-01

    To present a literature review on implant overdentures after a brief survey of bone loss after extraction of all teeth. Papers on alveolar bone loss and implant overdentures have been studied for a narrative review. Bone loss of the alveolar process after tooth extraction occurs with great individual variation, impossible to predict at the time of extraction. The simplest way to prevent bone loss is to avoid extraction of all teeth. To keep a few teeth and use them or their roots for a tooth or root-supported overdenture substantially reduces bone loss. Jaws with implant-supported prostheses show less bone loss than jaws with conventional dentures. Mandibular 2-implant overdentures provide patients with better outcomes than do conventional dentures, regarding satisfaction, chewing ability and oral-health-related quality of life. There is no strong evidence for the superiority of one overdenture retention-system over the others regarding patient satisfaction, survival, peri-implant bone loss and relevant clinical factors. Mandibular single midline implant overdentures have shown promising results but long-term results are not yet available. For a maxillary overdenture 4 to 6 implants splinted with a bar provide high survival both for implants and overdenture. In edentulous mandibles, 2-implant overdentures provide excellent long-term success and survival, including patient satisfaction and improved oral functions. To further reduce the costs a single midline implant overdenture can be a promising option. In the maxilla, overdentures supported on 4 to 6 implants splinted with a bar have demonstrated good functional results.

  6. Implant and root supported overdentures - a literature review and some data on bone loss in edentulous jaws

    PubMed Central

    2014-01-01

    PURPOSE To present a literature review on implant overdentures after a brief survey of bone loss after extraction of all teeth. MATERIALS AND METHODS Papers on alveolar bone loss and implant overdentures have been studied for a narrative review. RESULTS Bone loss of the alveolar process after tooth extraction occurs with great individual variation, impossible to predict at the time of extraction. The simplest way to prevent bone loss is to avoid extraction of all teeth. To keep a few teeth and use them or their roots for a tooth or root-supported overdenture substantially reduces bone loss. Jaws with implant-supported prostheses show less bone loss than jaws with conventional dentures. Mandibular 2-implant overdentures provide patients with better outcomes than do conventional dentures, regarding satisfaction, chewing ability and oral-health-related quality of life. There is no strong evidence for the superiority of one overdenture retention-system over the others regarding patient satisfaction, survival, peri-implant bone loss and relevant clinical factors. Mandibular single midline implant overdentures have shown promising results but long-term results are not yet available. For a maxillary overdenture 4 to 6 implants splinted with a bar provide high survival both for implants and overdenture. CONCLUSION In edentulous mandibles, 2-implant overdentures provide excellent long-term success and survival, including patient satisfaction and improved oral functions. To further reduce the costs a single midline implant overdenture can be a promising option. In the maxilla, overdentures supported on 4 to 6 implants splinted with a bar have demonstrated good functional results. PMID:25177466

  7. Evaluation of mechanical and thermal properties of commonly used denture base resins.

    PubMed

    Phoenix, Rodney D; Mansueto, Michael A; Ackerman, Neal A; Jones, Robert E

    2004-03-01

    The purpose of this investigation was to evaluate and compare the mechanical and thermal properties of 6 commonly used polymethyl methacrylate denture base resins. Sorption, solubility, color stability, adaptation, flexural stiffness, and hardness were assessed to determine compliance with ADA Specification No. 12. Thermal assessments were performed using differential scanning calorimetry and dynamic mechanical analysis. Results were assessed using statistical and observational analyses. All materials satisfied ADA requirements for sorption, solubility, and color stability. Adaptation testing indicated that microwave-activated systems provided better adaptation to associated casts than conventional heat-activated resins. According to flexural testing results, microwaveable resins were relatively stiff, while rubber-modified resins were more flexible. Differential scanning calorimetry indicated that microwave-activated systems were more completely polymerized than conventional heat-activated materials. The microwaveable resins displayed better adaptation, greater stiffness, and greater surface hardness than other denture base resins included in this investigation. Elastomeric toughening agents yielded decreased stiffness, decreased surface hardness, and decreased glass transition temperatures.

  8. Silver distribution and release from an antimicrobial denture base resin containing silver colloidal nanoparticles.

    PubMed

    Monteiro, Douglas Roberto; Gorup, Luiz Fernando; Takamiya, Aline Satie; de Camargo, Emerson Rodrigues; Filho, Adhemar Colla Ruvolo; Barbosa, Debora Barros

    2012-01-01

    The aim of this study was to evaluate a denture base resin containing silver colloidal nanoparticles through morphological analysis to check the distribution and dispersion of these particles in the polymer and by testing the silver release in deionized water at different time periods. A Lucitone 550 denture resin was used, and silver nanoparticles were synthesized by reduction of silver nitrate with sodium citrate. The acrylic resin was prepared in accordance with the manufacturers' instructions, and silver nanoparticle suspension was added to the acrylic resin monomer in different concentrations (0.05, 0.5, and 5 vol% silver colloidal). Controls devoid of silver nanoparticles were included. The specimens were stored in deionized water at 37°C for 7, 15, 30, 60, and 120 days, and each solution was analyzed using atomic absorption spectroscopy. Silver was not detected in deionized water regardless of the silver nanoparticles added to the resin and of the storage period. Micrographs showed that with lower concentrations, the distribution of silver nanoparticles was reduced, whereas their dispersion was improved in the polymer. Moreover, after 120 days of storage, nanoparticles were mainly located on the surface of the nanocomposite specimens. Incorporation of silver nanoparticles in the acrylic resin was evidenced. Moreover, silver was not detected by the detection limit of the atomic absorption spectrophotometer used in this study, even after 120 days of storage in deionized water. Silver nanoparticles are incorporated in the PMMA denture resin to attain an effective antimicrobial material to help control common infections involving oral mucosal tissues in complete denture wearers. © 2011 by the American College of Prosthodontists.

  9. Two-unit cantilevered resin-bonded fixed partial denture as a substitute for a prosthodontic-orthodontic treatment plan: a 5-year case report.

    PubMed

    Emami, Elham; St-Georges, Annie; de Grandmont, Pierre

    2012-01-01

    In this case report, we describe the successful long-term treatment of a patient with dental agenesis. The initial treatment plan included an orthodontic phase to provide adequate space for replacing missing lateral incisors with implants. However, because of some complications encountered after 2 years of orthodontic treatment, a revised treatment plan was considered to achieve functional and esthetic goals. The patient was completely satisfied 5 years after being treated with two 2-unit cantilevered resin-bonded fixed partial dentures supported by the cuspids. This conservative treatment plan was cost-effective without having any significant biological cost.

  10. [The paper summarizes data on laboratory and clinical assessment of Corega dent Laboratory and clinical analysis of Corega denture adhesive cream mechanical properties].

    PubMed

    Kalivradzhiyan, E S; Podoprigora, A V; Kaverina, E Yu; Bobeshko, M N

    The paper summarizes data on laboratory and clinical assessment of Corega denture adhesive cream adhesive properties: adhesion strength and time of adhesive material fixing. Clinical assessment was based on Ulitovsky-Leontyev denture fixation index evaluated in 18 edentulous patients with full removable dentures 1 and 12 months after denture manufacturing. After one year of evaluation denture fixation in patients using Corega denture adhesive cream was 8-15% better (depending on alveolar bed anatomy) than in controls proving that Corega improves full denture adaptation to physiological atrophy of alveolar bone.

  11. Effect of denture cleansers on color stability, surface roughness, and hardness of different denture base resins

    PubMed Central

    Porwal, Anand; Khandelwal, Meenakshi; Punia, Vikas; Sharma, Vivek

    2017-01-01

    Aim: The purpose of this study was to evaluate the effect of different denture cleansers on the color stability, surface hardness, and roughness of different denture base resins. Materials and Methods: Three denture base resin materials (conventional heat cure resin, high impact resin, and polyamide denture base resin) were immersed for 180 days in commercially available two denture cleansers (sodium perborate and sodium hypochlorite). Color, surface roughness, and hardness were measured for each sample before and after immersion procedure. Statistical Analysis: One-way analysis of variance and Tukey's post hoc honestly significant difference test were used to evaluate color, surface roughness, and hardness data before and after immersion in denture cleanser (α =0.05). Results: All denture base resins tested exhibited a change in color, surface roughness, and hardness to some degree in both denture cleansers. Polyamides resin immersed in sodium perborate showed a maximum change in color after immersion for 180 days. Conventional heat cure resin immersed in sodium hypochlorite showed a maximum change in surface roughness and conventional heat cure immersed in sodium perborate showed a maximum change in hardness. Conclusion: Color changes of all denture base resins were within the clinically accepted range for color difference. Surface roughness change of conventional heat cure resin was not within the clinically accepted range of surface roughness. The choice of denture cleanser for different denture base resins should be based on the chemistry of resin and cleanser, denture cleanser concentration, and duration of immersion. PMID:28216847

  12. Occlusal force discrimination by denture patients.

    PubMed

    Pacer, R J; Bowman, D C

    1975-06-01

    A study was conducted on subjects with conventional dentures and with overlay dentures to compare their abilities to discriminate between occlusal forces. Perpendicular forces were applied to the dynamic center of the occlusal table of the mandibular denture. Each subject's ability to distinguish differences in values of force was observed and recorded. All subjects with dentures showed sensory threshold values close to those reported for natural teeth. A graphic plotting showed that the responses of subjects with overlay-type dentures were more closely correlated with the psychophysical law as expressed by Stevens as a power function. Since this phenomenon holds true for natural teeth, the overlay denture more closely resembles natural teeth in this type of sensory function than does the conventional denture. In addition to recognized advantages, such as preservation of the ridge and improved retention and stability, the overlay denture provides more typical sensory function than is provided by the conventional denture. This advantage should further motivate dentists and patients to consider the retention and utilization of at least two suitable teeth in an overlay-type denture service.

  13. Evaluating the efficiency of humic acid to remove micro-organisms from denture base material.

    PubMed

    Meriç, Gökçe; Güvenir, Meryem; Süer, Kaya

    2016-09-01

    To evaluate the efficiency of humic acid substances on removing micro-organisms from denture base materials. Old denture wearer needs effective, easy-use and safe denture-cleaning material. Square-shaped, heat-polymerised acrylic resin specimens (n = 550) were prepared and divided into five groups (n = 110 for each) corresponding to the microbial contamination (Candida albicans, Staphylococcus aureus, Bacillus cereus, Enterococcus faecalis, Pseudomonas aeruginosa). Contaminated specimens were randomly assigned to the application of five different denture-cleaning agents as follows (n = 20 for each): Kloroben, Corsodyl, Steradent, Corega, experimental solution with humic acid. Ten specimens were assessed as an experimental control carried out simultaneously for the treatment groups for each micro-organism. It was divided into two groups: negative control and positive control (n = 5 for each). All acrylic specimens were incubated 37°C for 24 h (for bacterial strains) and 37°C for 48 h (for yeast strains). After incubation period, all brain-heart infusion broths (BHI) which contain disinfectant acrylic specimens were cultured on 5% sheep blood agar (for bacteria) and Sabouraud dextrose agar (SDA) for yeast using loop. The numbers of colony-forming units per millilitre (CFU/ml) were calculated. The results were analysed by Mann-Whitney U-test and Kruskal-Wallis tests (p = 0.05). Corsodyl and Kloroben completely eliminated the adherence of all investigated micro-organisms (100%) and showed the highest removal activity compared with other cleaning agents (p < 0.05). There was no statistically significant difference between Corsodyl and Kloroben (p ≥ 0.05), and there was no statistically significant difference between Corega, Steradent and experimental solution (p ≥ 0.05). Humic acid could be used as an alternative 'natural' solution for denture-cleaning agent. © 2014 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  14. Patients' experiences with partial dentures: a qualitative study.

    PubMed

    Smith, Patricia A; Entwistle, Vikki A; Nuttall, Nigel

    2005-12-01

    The aim of the study was to gain insight into people's experiences of being given and using partial dentures. In-depth semi-structured interviews were carried out with 23 people of varied age, social background and denture wearing experience in Tayside, Scotland. Participants were encouraged to discuss how they came to have partial dentures, their day-to-day denture use and their interactions with dentists. The interview data were systematically coded using key theme headings, and summary charts were constructed to facilitate analysis. The initial decision that a partial denture was needed was generally difficult to accept. People perceived the main benefits of partial dentures to be improved appearance and confidence, but experienced a variety of difficulties with their dentures and often coped with these by only wearing them on social occasions. Participants had not always told their dentists about the difficulties they experienced. Barriers to seeking help with denture problems included financial constraints, previous experience of rushed appointments or poor communication from dentists and a perceived lack of entitlement to help when partial dentures were issued free. Partial dentures can be difficult to cope with. People experience a range of difficulties in wearing them, not all of which have been discussed with dentists. Informative and supportive communication when partial dentures are first needed, and subsequently, can improve the quality of patients' experiences and may help promote effective use and appropriate help-seeking by partial denture wearers.

  15. Incomplete mobilization of the maxilla resulting in failed maxillary distraction: a case report.

    PubMed

    Alkan, Alper; Inal, Samet; Baş, Burcu; Ozer, Mete

    2007-12-01

    Maxillary distraction osteogenesis has become an accepted alternative method in the treatment of patients with severe maxillary hypoplasia in craniofacial syndromes and cleft-related deformities. Insufficient distraction, undesirable soft tissue changes, and occurrence of defective distraction vectors are among the potential complications of intraoral maxillary distraction osteogenesis. A 2-stage procedure combining maxillary advancement by distraction technique with genioplasty and mandibular setback surgery was planned to correct jaw deformities in a 22-year-old patient with severe maxillary retrusion, mandibular prognathism, and excessive lower facial height. In the first stage, osteotomies were performed and maxilla was lightly mobilized after down-fracture. Distractors were placed to the maxilla intraorally. During activation period, the maxilla rotated in a clockwise direction, producing a discrepancy between the planned and the actual vectors. Complete distraction was unsatisfactory and the complication was due to surgical technique. This case report presents the failure of maxillary distraction due to incomplete mobilization of the maxilla. Treatment of the case was achieved by the conventional osteotomy techniques at final operation. The maxilla was successfully advanced to the desired position producing good occlusion and an improved facial profile.

  16. Comparison of systemic health conditions between African American and Caucasian complete denture patients.

    PubMed

    Szylkowska, Ewelina; Kaste, Linda M; Schreiner, Joseph; Gordon, Sara C; Lee, Damian J

    2014-07-01

    To compare prevalence of systemic health conditions (SHC) between African American and Caucasian edentulous patients presenting for complete dentures (CD) at an urban dental school. The study included patients presenting for CD 1/1-12/31/2010, ages 20 to 64 years, and either African American or Caucasian. Covariates included: age group, gender, employment status, Medicaid status, smoking history, and alcohol consumption. SHC included at least one of the following: arthritis, asthma, cancer, diabetes, emphysema, heart attack, heart murmur, heart surgery, hypertension, or stroke. The group (n = 88) was 44.3% African American, 65.9% ≥50, 45.5% male, 22.7% employed, and 67.0% with at least one SHC. African Americans were older (p = 0.001) and more likely to have one or more SHC (p = 0.011). Patients with at least one SHC were older (p = 0.018) and more likely female (p = 0.012). The total sample logistic regression model assessing SHC yielded only gender as statistically significant (males < OR 0.32, 95% CI 0.11 to 0.92). Caucasian males were less likely to have SHC (OR 0.17, 95% CI 0.04 to 0.77), and Caucasians ≥50 were more likely (OR 5.36, 95% CI 1.19 to 24.08). African Americans yielded no significant associations. Among selected completely edentulous denture patients at an urban dental school, two out of three patients had at least one SHC. This exploratory study suggests there may be health status differences between African American and Caucasian patients in this setting, calling for further study. © 2014 by the American College of Prosthodontists.

  17. Candida albicans biofilm heterogeneity does not influence denture stomatitis but strongly influences denture cleansing capacity.

    PubMed

    O'Donnell, Lindsay E; Alalwan, Hasanain K A; Kean, Ryan; Calvert, Gareth; Nile, Christopher J; Lappin, David F; Robertson, Douglas; Williams, Craig; Ramage, Gordon; Sherry, Leighann

    2017-01-01

    Approximately 20  % of the UK population wear some form of denture prosthesis, resulting in denture stomatitis in half of these individuals. Candida albicans is primarily attributed as the causative agent, due to its biofilm -forming ability. Recently, there has been increasing evidence of C. albicans biofilm heterogeneity and the negative impact it can have clinically; however, this phenomenon has yet to be studied in relation to denture isolates. The aims of this study were to evaluate C. albicans biofilm formation of clinical denture isolates in a denture environment and to assess antimicrobial activity of common denture cleansers against these tenacious communities. C. albicans isolated from dentures of healthy and diseased individuals was quantified using real-time PCR and biofilm biomass assessed using crystal violet. Biofilm development on the denture substratum poly(methyl methacrylate), Molloplast B and Ufi-gel was determined. Biofilm formation was assessed using metabolic and biomass stains, following treatment with denture hygiene products. Although C. albicans was detected in greater quantities in diseased individuals, it was not associated with increased biofilm biomass. Denture substrata were shown to influence biofilm biomass, with poly(methyl methacrylate) providing the most suitable environment for C. albicans to reside. Of all denture hygiene products tested, Milton had the most effective antimicrobial activity, reducing biofilm biomass and viability the greatest. Overall, our results highlight the complex nature of denture- related disease, and disease development cannot always be attributed to a sole cause. It is the distinct combination of various factors that ultimately determines the pathogenic outcome.

  18. Management of bruxism-induced complications in removable partial denture wearers using specially designed dentures: a clinical report.

    PubMed

    Baba, Kazuyoshi; Aridome, Kumiko; Pallegama, Ranjith Wasantha

    2008-01-01

    In patients with a limited number of remaining teeth, bruxism force can be destructive for both the remaining teeth and periodontal structures. This paper reports the successful management of four such patients with severe sleep bruxism, using conventional removable partial dentures and specially designed, splint-like removable partial dentures called a night denture. The night denture was fabricated in two different designs, which depended upon the pattern of the remaining tooth contacts. The patients were followed up for 2-6 years using a night denture in either of the two designs. Within the limitations of these four reports of clinical cases, the night denture appeared to be effective in managing the problems related to sleep bruxism.

  19. Bonding of acrylic denture teeth to MMA/PMMA and light-curing denture base materials: the role of conditioning liquids.

    PubMed

    Palitsch, Anne; Hannig, Matthias; Ferger, Paul; Balkenhol, Markus

    2012-03-01

    The connection between resin denture teeth and the denture base is essential for the integrity of partial and full dentures. The aim of the present study was to analyse the bond strength of acrylic denture teeth to two light curing denture base materials compared to the gold-standard (MMA/PMMA) using different conditioning liquids. The ridge laps of 220 identical denture teeth were ground and pre-treated using different conditioning liquids (MMA, an experimental conditioning liquid as well as the two commercially available liquids Palabond and Versyo.bond). The denture base materials (PalaXpress, Versyo.com, Eclipse) were applied using a split mould to obtain tensile bond strength specimens of identical shape. Ten specimens per test group were either stored in water for 24h or thermocycled (5000×, 5-55°C) prior to tensile bond strength testing (cross-head speed 10mm/min). Data was subjected to parametric statistics (α=0.05). The three-way ANOVA revealed a significant influence of the material, pre-treatment as well as the storage. PalaXpress showed the highest bond strength (24.3MPa) of all materials tested after TC, whereas the use of MMA led to the most constant results. Lower values were recorded for Versyo.com (17.5MPa) and Eclipse (10.4MPa) bonded with Versyo.bond. The results indicate that MMA/PMMA based denture base resins provide reliable and durable bond strength to acrylic denture teeth. Using light-curing denture base materials requires the application of appropriate conditioning liquids to obtain acceptable bond strength. The use of MMA affects bond strength to light-curing denture base materials. The pre-treatment of denture teeth is critical regarding their bond-strength to denture base materials and in turn for the integrity of removable full and partial dentures. Light-curing denture base resins are more sensitive to the correct tooth pre-treatment compared to conventional MMA/PMMA materials, requiring specific conditioning liquids. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. [Predictability of maxillary distraction with the trans-sinusoidal distractor].

    PubMed

    Nadjmi, N

    2004-02-01

    This work was conducted to evaluate a new maxillary distractor with an activating system introduced into the maxilary sinus. Fourteen patients age 8 to 55 Years with severe maxillary and midfacial hypoplasia were treated in our center. A trans-sinusoidal maxillary distractor (TS-MD, developed by Dr. N. Nadjmi in cooperation with Martin, Tuttlingen, Germany) was placed intra-orally at each side of the maxilla. The distraction vector was predicted with devoted software (Medicim N.V Belgium), and was transferred to the patients using stereolithographic models and individual templates. A high Lefort I type osteotomy was performed. Forward maxillary movement at distractor level varied from 7 to 22 mm. Soft and hard tIssue formation resulted in complete healing across the distraction gaps. The maxillary movements and new bone formation in the sagittal, horizontal, and vertical planes could be predicted and achieved. Distractors were designed to allow clockwise rotation of the maxilla during the distraction phase allowing the correction of the anterior open-bite in all patients with this skeletal deformity. The distractors were almost completely submerged, and could be left in place as long as necessary to avoid relapse. The TS-MD distractor has the advantage of good tolerance since the most voluminous part is placed within the maxilary sinus. Implantation via an exclusively oral approach is a further advantage. The devise does not interfere with the patient's social life and does not require alveolodental fixation. The TS-MD distractor can also aleviate the need for bone grafting in cases with major advancement. Correct position of the vector is crucial but one-sided catch-up distraction is possible.

  1. Maxillary Sinus Dimensions Decrease as Age and Tooth Loss Increase.

    PubMed

    Velasco-Torres, Miguel; Padial-Molina, Miguel; Avila-Ortiz, Gustavo; García-Delgado, Raúl; OʼValle, Francisco; Catena, Andrés; Galindo-Moreno, Pablo

    2017-04-01

    To investigate the correlation between patient-dependent variables and dimensional variations of the maxillary sinus. In this cross-sectional study, a total of 394 individual cone-beam computed tomography scans were evaluated by one calibrated examiner to measure the total volume of the maxillary sinus, the distance between the medial and the lateral walls at 5, 10, and 15 mm vertically from the sinus floor, the height of septa (if present), and the height of the maxillary sinus cavity from both the alveolar crest and the sinus floor to the meatus. Recorded patient-dependent variables were age, gender, and edentulism status. Total maxillary sinus volume was significantly smaller in completely and partially edentulous patients than in dentate subjects. This finding was influenced by age, as older patients exhibited less volume, regardless of gender and edentulism status. Age showed an indirect correlation with the distance to the meatus, the sinus volume, and the mediolateral dimensions. Additionally, the prevalence of accessory meatus in this population was 29.19%. The dimensions of the maxillary sinus are influenced by age and edentulism status being reduced by aging and tooth loss.

  2. Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques.

    PubMed

    Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T

    2018-01-01

    Data comparing the denture tooth movement of computer-aided design and computer-aided manufacturing (CAD-CAM) and conventional denture processing techniques are lacking. The purpose of this in vitro study was to compare the denture tooth movement of pack-and-press, fluid resin, injection, CAD-CAM-bonded, and CAD-CAM monolithic techniques for fabricating dentures to determine which process produces the most accurate and reproducible prosthesis. A total of 50 dentures were evaluated, 10 for each of the 5 groups. A master denture was fabricated and milled from prepolymerized poly(methyl methacrylate). For the conventional processing techniques (pack-and-press, fluid resin, and injection) a polyvinyl siloxane putty mold of the master denture was made in which denture teeth were placed and molten wax injected. The cameo surface of each wax-festooned denture was laser scanned, resulting in a standard tessellation language (STL) format file. The CAD-CAM dentures included 2 subgroups: CAD-CAM-bonded teeth in which the denture teeth were bonded into the milled denture base and CAD-CAM monolithic teeth in which the denture teeth were milled as part of the denture base. After all specimens had been fabricated, they were hydrated for 24 hours, and the cameo surface laser scanned. The preprocessing and postprocessing scan files of each denture were superimposed using surface-matching software. Measurements were made at 64 locations, allowing evaluation of denture tooth movement in a buccal, lingual, mesial-distal, and occlusal direction. The use of median and interquartile range values was used to assess accuracy and reproducibility. Levene and Kruskal-Wallis analyses of variance were used to evaluate differences between processing techniques (α=.05). The CAD-CAM monolithic technique was the most accurate, followed by fluid resin, CAD-CAM-bonded, pack-and-press, and injection. CAD-CAM monolithic technique was the most reproducible, followed by pack-and-press, CAD-CAM-bonded, injection, and fluid resin. Techniques involving compression during processing showed increased positive occlusal tooth movement compared with techniques not involving compression. CAD-CAM monolithic dentures produced the best combination of accuracy and reproducibility of the tested techniques. The results from this study demonstrate that varying amounts of tooth movement can be expected depending on the processing technique. However, the clinical significance of these differences is unknown. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. Sex Determination of Adult Human Maxillary Sinuses on Panoramic Radiographs

    PubMed Central

    Leao de Queiroz, Cristhiane; Terada, Andrea Sayuri Silveira Dias; Dezem, Thais Uenoyama; Gomes de Araújo, Lais; Galo, Rodrigo; Oliveira-Santos, Christiano

    2016-01-01

    Absract The purpose of this study was to evaluate dimensions of adult human maxillary sinuses on panoramic radiographs and their possible application on the sex determination for forensic purposes. The sample comprised 64 database panoramic radiographs from individuals aged 20 years or older (32 male and 32 female subjects), with complete permanent dentition (or absence of third molars). One examiner measured the width and height of the right and left maxillary sinuses using the software Image J 1.47v (National Institutes of Health, Bethesda, USA). Measurements were repeated to calculate intra-observer agreement. Chi-Square test, Kappa, ANOVA and T-Student were used for results analysis for p≤ 0.05. Intra-observer agreement with correlation Kappa ranged between 0.38 and 0.96. For female subjects, the mean height and width of the left maxillary sinus were 28.7856mm and 44.6178mm, respectively. And right maxillary sinus was 27.7163mm for height and 45.1850mm for width. Male subjects were found to have the mean height and width of the left maxillary sinus 30.9981mm and 48.7753mm, respectively. And right maxillary sinus was 30.7403mm for height and 48.5753mm for width. There was a statistically significant difference in the height and width of maxillary sinuses between males and females. It can be concluded that maxillary sinuses height and width on panoramic radiographs can be used to determine the gender of adult human subjects. PMID:27847394

  4. In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins.

    PubMed

    Steinmassl, Otto; Offermanns, Vincent; Stöckl, Wolfgang; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca

    2018-03-08

    Computer-aided design and computer-aided manufacturing (CAD/CAM) denture base manufacturers claim to produce their resin pucks under high heat and pressure. Therefore, CAD/CAM dentures are assumed to have enhanced mechanical properties and, as a result, are often produced with lower denture base thicknesses than conventional, manually fabricated dentures. The aim of this study was to investigate if commercially available CAD/CAM denture base resins have more favourable mechanical properties than conventionally processed denture base resins. For this purpose, a series of three-point bending tests conforming to ISO specifications were performed on a total of 80 standardised, rectangular CAD/CAM denture base resin specimens from five different manufacturers (AvaDent, Baltic Denture System, Vita VIONIC, Whole You Nexteeth, and Wieland Digital Dentures). A heat-polymerising resin and an autopolymerising resin served as the control groups. The breaking load, fracture toughness, and the elastic modulus were assessed. Additionally, the fracture surface roughness and texture were investigated. Only one CAD/CAM resin showed a significantly increased breaking load. Two CAD/CAM resins had a significantly higher fracture toughness than the control groups, and all CAD/CAM resins had higher elastic moduli than the controls. Our results indicate that CAD/CAM denture base resins do not generally have better mechanical properties than manually processed resins. Therefore, the lower minimum denture base thicknesses should be regarded with some caution.

  5. In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins

    PubMed Central

    Stöckl, Wolfgang; Dumfahrt, Herbert; Grunert, Ingrid

    2018-01-01

    Computer-aided design and computer-aided manufacturing (CAD/CAM) denture base manufacturers claim to produce their resin pucks under high heat and pressure. Therefore, CAD/CAM dentures are assumed to have enhanced mechanical properties and, as a result, are often produced with lower denture base thicknesses than conventional, manually fabricated dentures. The aim of this study was to investigate if commercially available CAD/CAM denture base resins have more favourable mechanical properties than conventionally processed denture base resins. For this purpose, a series of three-point bending tests conforming to ISO specifications were performed on a total of 80 standardised, rectangular CAD/CAM denture base resin specimens from five different manufacturers (AvaDent, Baltic Denture System, Vita VIONIC, Whole You Nexteeth, and Wieland Digital Dentures). A heat-polymerising resin and an autopolymerising resin served as the control groups. The breaking load, fracture toughness, and the elastic modulus were assessed. Additionally, the fracture surface roughness and texture were investigated. Only one CAD/CAM resin showed a significantly increased breaking load. Two CAD/CAM resins had a significantly higher fracture toughness than the control groups, and all CAD/CAM resins had higher elastic moduli than the controls. Our results indicate that CAD/CAM denture base resins do not generally have better mechanical properties than manually processed resins. Therefore, the lower minimum denture base thicknesses should be regarded with some caution. PMID:29518022

  6. Assessment of Hygiene Habits in Acrylic Denture Wearers: a Cross-sectional Study

    PubMed Central

    Aoun, Georges; Gerges, Elie

    2017-01-01

    Objectives: To assess the denture hygiene habits in a population of Lebanese denture wearers. Materials and Methods: One hundred and thirty-two (132) patients [71 women (53.8%) and 61 men (46.2%)] wearing their acrylic dentures for more than two years were included in this study. The hygiene methods related to their dentures were evaluated and the data obtained were analyzed statistically using the IBM® SPSS® statistics 20.0 (USA) statistical package. Results: Regardless of the cleaning technique, the big majority of our participants [123 out of 132 (93.1%)] cleaned their dentures daily. The two mostly used denture cleaning techniques were rinsing with tap water (34.1%) and brushing with toothpaste (31.8%). Nearly half of our patients (45.5%) soaked their dentures during the night; most of them with cleansing tablets dissolved in water (28.8%). Conclusions: Within the limitations of our study, it was concluded that in a sample of Lebanese population surveyed about denture hygiene habits, the daily frequency of denture cleaning is satisfactory, but the techniques and products used were self-estimated and, consequently, not sufficient. PMID:29109670

  7. An investigation into denture loss in hospitals in Kent, Surrey and Sussex.

    PubMed

    Mann, J; Doshi, M

    2017-08-25

    Background The loss of dentures for inpatients can have a detrimental effect on their well-being. Self-respect and dignity become compromised along with their ability to eat meals and communicate clearly, and long-term recovery.Aim This investigation aimed to identify the reported number of dentures lost in hospitals and the financial reimbursements given by trusts to replace them.Method Information on reported denture loss and reimbursement was collected in 12 trusts throughout Kent, Surrey and Sussex.Results Eleven out of 12 trusts returned data about how many dentures were lost in their hospitals, between them 695 dentures were reported lost over five years (2011-16). Seven trusts reported financial reimbursements for dentures losses; results showed £357,672 was reimbursed over six years (2010-16), the highest amount reimbursed for a single denture was £2,200.Conclusion The results indicate that denture loss is a problem in hospitals that contributes to the financial burden for the NHS. Consideration needs to be given by hospitals to find ways to reduce the number of dentures lost every year.

  8. [Stress distribution in abutment teeth and related tissues under different design of connector: three-dimensional finite element analysis].

    PubMed

    Bai, Li-Ming; Li, Guo-Qiang; Zhang, Qiang; Dong, Xian

    2016-08-01

    To compare the stress distribution in abutment teeth and related tissues under the same material and different loading between improved major connector design and traditional major connector design. One 55-year-old male patient with unilateral maxillary first molar and second molar missing was chosen. The stress distribution in abutment teeth and related tissues were evaluated with spiral CT scanning, Mimics, Geomagic Studio software, a study model was built and finite element analysis was performed using ANSYS software. With the improved major connector design, the stress of abutment decreased significantly, the stress of periodontal decreased, the stress of edentulous mucosa increased significantly and became more balanced, the trend of stimulated absorption of alveolar bone decreased. For patients with distal free defect of dentition, the design of improved major connector has the effect of stress interruption, can protect the abutment better, detract the stress of the denture and has an good protective effect on the edentulous mucosa and alveolar bone.

  9. Additively manufactured sub-periosteal jaw implants.

    PubMed

    Mommaerts, M Y

    2017-07-01

    Severe bone atrophy jeopardizes the success of endosseous implants. This technical note aims to present the innovative concept of additively manufactured sub-periosteal jaw implants (AMSJIs). Digital datasets of the patient's jaws and wax trial in occlusion are used to segment the bone and dental arches, for the design of a sub-periosteal frame and abutments in the optimal location related to the dental arch and for the design of the suprastructure. The implants and suprastructure are three-dimensionally (3D) printed in titanium alloy. The provisional denture is 3D-printed in polymer. AMSJIs offer an alternative approach for patients with extreme jaw bone atrophy. This report refers to the use of this technique for full maxillary rehabilitation, but partial defects in either jaw and extended post-resection defects may also be approached using the same technique. This customized, prosthesis-driven reverse-engineering approach avoids bone grafting and provides immediate functional restoration with one surgical session. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Partial Edentulism and its Correlation to Age, Gender, Socio-economic Status and Incidence of Various Kennedy’s Classes– A Literature Review

    PubMed Central

    Krishnan, Chitra Shankar

    2015-01-01

    Partial edentulism, one or more teeth missing is an indication of healthy behaviour of dental practices in the society and attitude towards dental and oral care. The pattern of partial edentulism has been evaluated in many selected populations in different countries by different methods. Most of the studies have evaluated partial edentulism by surveying of Removable Partial Dentures (RPDs), patients visiting clinics, clinical records and population in particular locality. The objective of the study is to review the prevalence of partial edentulousness and its correlation to age,gender, arch predominance, socio economic factors and incidence of various Kennedy’s Classes. Key observations drawn from the review are as below. There is no gender correlation for partial edentulism.Prevalence of partial edentulism is more common in mandibular arch than maxillary arch.Younger adults have more Class III and IV RPDs. Elders have more distal extension RPDs Class I and II. PMID:26266237

  11. Implant-supported Oral Rehabilitation in Child with Ectodermal Dysplasia - 4-year Follow-up.

    PubMed

    Cezária Triches, Thaisa; Ximenes, Marcos; Oliveira de Souza, João Gustavo; Rodrigues Lopes Pereira Neto, Armando; Cardoso, Antônio Carlos; Bolan, Michele

    2017-01-01

    Ectodermal dysplasia (ED) is an anomaly determined by genetic factors that alter ectodermal structures such as skin, hair, nails, glands, and teeth. Children affected by this condition require extensive, comprehensive, and multidisciplinary treatment. An 8-year-old female patient visited the Dentistry Clinic of the Federal University of Santa Catarina with the chief complaint of multiple missing teeth. The mother reported that the patient had ED. Clinical and radiographic examination revealed the congenital absence of several primary and permanent teeth and tooth germs. Subsequent oral rehabilitation comprised the application of a maxillary denture and mandibular implant-supported fixed prosthesis. The child was also supplied with a wig for further enhancement of esthetics aimed at improving her emotional wellbeing. Psychological follow-up and speech therapy were also provided. After 4 years of follow-up, implant-supported oral rehabilitation has proved to be a satisfactory treatment option, allowing restoration of masticatory, phonetic, and esthetic function, as well as an improvement in the patient's self-esteem and social wellbeing.

  12. Partial Edentulism and its Correlation to Age, Gender, Socio-economic Status and Incidence of Various Kennedy's Classes- A Literature Review.

    PubMed

    Jeyapalan, Vidhya; Krishnan, Chitra Shankar

    2015-06-01

    Partial edentulism, one or more teeth missing is an indication of healthy behaviour of dental practices in the society and attitude towards dental and oral care. The pattern of partial edentulism has been evaluated in many selected populations in different countries by different methods. Most of the studies have evaluated partial edentulism by surveying of Removable Partial Dentures (RPDs), patients visiting clinics, clinical records and population in particular locality. The objective of the study is to review the prevalence of partial edentulousness and its correlation to age,gender, arch predominance, socio economic factors and incidence of various Kennedy's Classes. Key observations drawn from the review are as below. There is no gender correlation for partial edentulism.Prevalence of partial edentulism is more common in mandibular arch than maxillary arch.Younger adults have more Class III and IV RPDs. Elders have more distal extension RPDs Class I and II.

  13. "Redefining smile-a multidisciplinary approach".

    PubMed

    Manne, Prakash; Zakkula, Srujana; Atla, Jyothi; Muvva, Suresh Babu; Sampath, Anche

    2013-07-01

    This article presents a case report of a 20 year old female who was very much dissatisfied with her facial appearance and smile.On examination, it was found that there was a Angles class II division 1 malocclusion and a generalised spacing in the anterior teeth, with a retained, deciduous, left maxillary canine and a malposed 15. On radiographic examination, an impacted 18, 23 was noticed. As the part of the treatment plan, the retained deciduous canine and the impacted permanent canine were extracted and an orthodontic correction of the malocclusion was accomplished. The missing canine was planned to be replaced with a fixed partial denture.The short clinical crown height of the abutment teeth was increased by crown lengthening procedures and the pontic space was contoured to receive a ovate pontic by using diode lasers. The missing tooth was restored by using an all ceramic three unit zirconia bridge. This multi-disciplinary approach improved the smile of the patient and it ultimately enhanced her aesthetics and self confidence.

  14. “Redefining Smile-A Multidisciplinary Approach”

    PubMed Central

    Manne, Prakash; Zakkula, Srujana; Atla, Jyothi; Muvva, Suresh Babu; Sampath, Anche

    2013-01-01

    This article presents a case report of a 20 year old female who was very much dissatisfied with her facial appearance and smile.On examination, it was found that there was a Angles class II division 1 malocclusion and a generalised spacing in the anterior teeth, with a retained, deciduous, left maxillary canine and a malposed 15. On radiographic examination, an impacted 18, 23 was noticed. As the part of the treatment plan, the retained deciduous canine and the impacted permanent canine were extracted and an orthodontic correction of the malocclusion was accomplished. The missing canine was planned to be replaced with a fixed partial denture.The short clinical crown height of the abutment teeth was increased by crown lengthening procedures and the pontic space was contoured to receive a ovate pontic by using diode lasers. The missing tooth was restored by using an all ceramic three unit zirconia bridge. This multi–disciplinary approach improved the smile of the patient and it ultimately enhanced her aesthetics and self confidence. PMID:23998114

  15. The effect of joint surface contours and glass fiber reinforcement on the transverse strength of repaired acrylic resin: An in vitro study.

    PubMed

    Anasane, Nayana; Ahirrao, Yogesh; Chitnis, Deepa; Meshram, Suresh

    2013-03-01

    Denture fracture is an unresolved problem in complete denture prosthodontics. However, the repaired denture often experiences a refracture at the repaired site due to poor transverse strength. Hence, this study was conducted to evaluate the effect of joint surface contours and glass fiber reinforcement on the transverse strength of repaired acrylic resins. A total of 135 specimens of heat polymerized polymethyl methacrylate resin of dimensions 64 × 10 × 2.5 mm were fabricated. Fifteen intact specimens served as the control and 120 test specimens were divided into four groups (30 specimens each), depending upon the joint surface contour (butt, bevel, rabbet and round), with two subgroups based on type of the repair. Half of the specimens were repaired with plain repair resin and the other half with glass fibers reinforced repair resin. Transverse strength of the specimens was determined using three-point bending test. The results were analyzed using one-way ANOVA and Tukey post-hoc test (α= 0.05). Transverse strength values for all repaired groups were significantly lower than those for the control group (P < 0.001) (88.77 MPa), with exception of round surface design repaired with glass fiber reinforced repair resin (89.92 MPa) which was significantly superior to the other joint surface contours (P < 0.001). Glass fiber reinforced resin significantly improved the repaired denture base resins as compared to the plain repair resin (P < 0.001). Specimens repaired with glass fiber reinforced resin and round surface design exhibited highest transverse strength; hence, it can be advocated for repair of denture base resins.

  16. The effect of cleaning substances on the surface of denture base material.

    PubMed

    Žilinskas, Juozas; Junevičius, Jonas; Česaitis, Kęstutis; Junevičiūtė, Gabrielė

    2013-12-11

    The aim of this study was to evaluate the effect of substances used for hygienic cleaning of dentures on the surface of the denture base material. Meliodent Heat Cure (Heraeus-Kulzer, Germany) heat-polymerized acrylic resin was used to produce plates with all the characteristics of removable denture bases (subsequently, "plates"). Oral-B Complete toothbrushes of various brush head types were fixed to a device that imitated tooth brushing movements; table salt and baking soda (frequently used by patients to improve tooth brushing results), toothpaste ("Colgate Total"), and water were also applied. Changes in plate surfaces were monitored by measuring surface reflection alterations on spectrometry. Measurements were conducted before the cleaning and at 2 and 6 hours after cleaning. No statistically significant differences were found between the 3 test series. All 3 plates used in the study underwent statistically significant (p<0.05 changed)--the reflection became poorer. The plates were most affected by the medium-bristle toothbrush with baking soda--the total reflection reduction was 4.82 ± 0.1%; among toothbrushes with toothpaste, the hard-type toothbrush had the greatest reflection-reducing effect--4.6 ± 0.05%, while the toothbrush with table salt inflicted the least damage (3.5 ± 0.16%) due to the presence of rounded crystals between the bristles and the resin surface. Toothbrushes with water had a uniform negative effect on the plate surface - 3.8 9 ± 0.07%. All substances used by the patients caused surface abrasion of the denture base material, which reduced the reflection; a hard toothbrush with toothpaste had the greatest abrasive effect, while soft toothbrushes inflicted the least damage.

  17. A comparison of patient satisfaction and dentist evaluation of overdenture therapy.

    PubMed

    Ettinger, R L; Jakobsen, J R

    1997-06-01

    It has been argued that the retention of some teeth in the jaws as overdenture abutments prevents negative feelings about the loss of natural teeth. This study set out to evaluate how satisfied a group of patients were with wearing overdentures, and to compare their subjective evaluations with those of a dentist using objective criteria to examine the prostheses. A questionnaire was developed using questions adapted from several other studies. It was pretested, modified and used on all patients who were members of a longitudinal study of overdentures that started in 1974, and who returned on recall. At the end of 9 months, 101 subjects had completed the questionnaire and examination. The mean age of the patients was 65.9 years with an age range of 35 to 88 years. There were 68 men and 33 women in this study and 62 of them were satisfied with their dentures; 33 were satisfied, but felt they had some faults. Only 6 were unhappy about wearing the overdentures. The average length of time the dentures had been worn was 6.9 years, with a range of 1 to 15 years. The most frequent complaints were loss of retention (65.4%) and discomfort (62.2%) of the mandibular dentures. A number of correlations were evaluated and some significant relationships were found between dentist and patient evaluation of the dentures. The best predictor of patient satisfaction with denture wearing was the patient's perception of retention and appearance. In the maxilla the patient's ability to chew and the dentist's evaluation of occlusion were also significant predictors. In the mandible the only other factors apart from retention and appearance were patient comfort and age.

  18. A new concept in denture design for patients with few remaining teeth: case reports.

    PubMed

    Ling, B C

    1995-12-01

    This article presents an alternative to the conventional swing-lock de sign of removable partial denture construction. It incorporates the principles of sectional dentures as well as the swing-lock concept and overcomes some of the limitations of conventional swing-lock dentures. I-bar struts and stainless steel keepers form part of the first section of the denture. The second part of the denture consists of the denture base with the artificial teeth and magnetic retention units. This system has been used successfully in a number of patients whose situations were suitable for the conventional swing-lock design.

  19. Segmental maxillary distraction with a novel device for closure of a wide alveolar cleft

    PubMed Central

    Bousdras, Vasilios A.; Liyanage, Chandra; Mars, Michael; Ayliffe, Peter R

    2014-01-01

    Treatment of a wide alveolar cleft with initial application of segmental distraction osteogenesis is reported, in order to minimise cleft size prior to secondary alveolar bone grafting. The lesser maxillary segment was mobilised with osteotomy at Le Fort I level and, a novel distractor, facilitated horizontal movement of the dental/alveolar segment along the curvature of the maxillary dental arch. Following a latency period of 4 days distraction was applied for 7 days at a rate of 0.5 mm twice daily. Radiographic, ultrasonographic and clinical assessment revealed new bone and soft tissue formation 8 weeks after completion of the distraction phase. Overall the maxillary segment did move minimising the width of the cleft, which allowed successful closure with a secondary alveolar bone graft. PMID:24987601

  20. Segmental maxillary distraction with a novel device for closure of a wide alveolar cleft.

    PubMed

    Bousdras, Vasilios A; Liyanage, Chandra; Mars, Michael; Ayliffe, Peter R

    2014-01-01

    Treatment of a wide alveolar cleft with initial application of segmental distraction osteogenesis is reported, in order to minimise cleft size prior to secondary alveolar bone grafting. The lesser maxillary segment was mobilised with osteotomy at Le Fort I level and, a novel distractor, facilitated horizontal movement of the dental/alveolar segment along the curvature of the maxillary dental arch. Following a latency period of 4 days distraction was applied for 7 days at a rate of 0.5 mm twice daily. Radiographic, ultrasonographic and clinical assessment revealed new bone and soft tissue formation 8 weeks after completion of the distraction phase. Overall the maxillary segment did move minimising the width of the cleft, which allowed successful closure with a secondary alveolar bone graft.

  1. The Palatal Window for Treating an Incompletely Augmented Maxillary Sinus.

    PubMed

    Florio, Salvatore; Suzuki, Takanori; Cho, Sang-Choon

    2017-04-01

    Maxillary sinus augmentation through a lateral window is reported as one of the most predictable bone augmentation procedures before implant placement. The elevation of the membrane represents a delicate and crucial step that allows the creation of the space for the bone graft material. If the elevation is not completed, the regenerated bone might be inadequate for the implant placement. In this case, a new intervention will be necessary to complete the bone augmentation. Reaccessing from a lateral window, however, would be challenging due to thickness of the buccal boney wall because of the first grafting procedure; therefore, a different approach has to be used. The aim of this case report is to present the palatal window technique for treating incompletely augmented maxillary sinus. The detailed step-by-step diagnostic and surgical procedures are described, and the advantages and limitations of the technique are discussed through a review of the literature.

  2. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... with the oral tissues. After the denture base is constructed, the connected preformed teeth are...: Evaluation and Testing,’ ” and (2) “OTC Denture Reliners, Repair Kits, and Partially Fabricated Denture Kits...

  3. Effect of Maxillary Osteotomy on Speech in Cleft Lip and Palate: Perceptual Outcomes of Velopharyngeal Function

    ERIC Educational Resources Information Center

    Pereira, Valerie J.; Sell, Debbie; Tuomainen, Jyrki

    2013-01-01

    Background: Abnormal facial growth is a well-known sequelae of cleft lip and palate (CLP) resulting in maxillary retrusion and a class III malocclusion. In 10-50% of cases, surgical correction involving advancement of the maxilla typically by osteotomy methods is required and normally undertaken in adolescence when facial growth is complete.…

  4. Rehabilitative treatment of cleft lip and palate: experience of the Hospital for Rehabilitation of Craniofacial Anomalies - USP (HRAC-USP) - Part 2: Pediatric Dentistry and Orthodontics

    PubMed Central

    FREITAS, José Alberto de Souza; GARIB, Daniela Gamba; OLIVEIRA, Thais Marchini; LAURIS, Rita de Cássia Moura Carvalho; de ALMEIDA, Ana Lúcia Pompéia Fraga; NEVES, Lucimara Teixeira; TRINDADE-SUEDAM, Ivy Kiemle; YAEDÚ, Renato Yassutaka Faria; SOARES, Simone; PINTO, João Henrique Nogueira

    2012-01-01

    The aim of this article is to present the pediatric dentistry and orthodontic treatment protocol of rehabilitation of cleft lip and palate patients performed at the Hospital for Rehabilitation of Craniofacial Anomalies - University of São Paulo (HRAC-USP). Pediatric dentistry provides oral health information and should be able to follow the child with cleft lip and palate since the first months of life until establishment of the mixed dentition, craniofacial growth and dentition development. Orthodontic intervention starts in the mixed dentition, at 8-9 years of age, for preparing the maxillary arch for secondary bone graft procedure (SBGP). At this stage, rapid maxillary expansion is performed and a fixed palatal retainer is delivered before SBGP. When the permanent dentition is completed, comprehensive orthodontic treatment is initiated aiming tooth alignment and space closure. Maxillary permanent canines are commonly moved mesially in order to substitute absent maxillary lateral incisors. Patients with complete cleft lip and palate and poor midface growth will require orthognatic surgery for reaching adequate anteroposterior interarch relationship and good facial esthetics. PMID:22666849

  5. Odor Coding in the Maxillary Palp of the Malaria Vector Mosquito Anopheles gambiae

    PubMed Central

    Lu, Tan; Qiu, Yu Tong; Wang, Guirong; Kwon, Jae Young; Rutzler, Michael; Kwon, Hyung-Wook; Pitts, R. Jason; van Loon, Joop J.A.; Takken, Willem; Carlson, John R.; Zwiebel, Laurence J.

    2011-01-01

    Summary Background Many species of mosquitoes, including the major malaria vector Anopheles gambiae, utilize carbon dioxide (CO2) and 1-octen-3-ol as olfactory cues in host-seeking behaviors that underlie their vectorial capacity. However, the molecular and cellular basis of such olfactory responses remains largely unknown. Results Here, we use molecular and physiological approaches coupled with systematic functional analyses to define the complete olfactory sensory map of the An. gambiae maxillary palp, an olfactory appendage that mediates the detection of these compounds. In doing so, we identify three olfactory receptor neurons (ORNs) that are organized in stereotyped triads within the maxillary-palp capitate-peg-sensillum population. One ORN is CO2-responsive and characterized by the coexpression of three receptors that confer CO2 responses, whereas the other ORNs express characteristic odorant receptors (AgORs) that are responsible for their in vivo olfactory responses. Conclusions Our results describe a complete and highly concordant map of both the molecular and cellular olfactory components on the maxillary palp of the adult female An. gambiae mosquito. These results also facilitate the understanding of how An. gambiae mosquitoes sense olfactory cues that might be exploited to compromise their ability to transmit malaria. PMID:17764944

  6. Endodontic management of maxillary first molar with seven root canals diagnosed using Cone Beam Computed Tomography scanning

    PubMed Central

    Raghavendra, Srinidhi Surya; Hindlekar, Ajit Narayan; Desai, Niranjan Nanasaheb; Vyavahare, Nishant Kishor; Napte, Bandu Devrao

    2014-01-01

    The main objective of root canal treatment is thorough cleaning and shaping of the entire pulp space and its complete filling with an inert filling material. A major cause of post-treatment disease is the inability to locate, debride or adequately fill all canals of the root canal system. The form, configuration, and number of root canals in the maxillary first molars have been discussed for more than half a century. Maxillary first molars commonly present with three roots and three canals, with a second mesiobuccal canal (MB2) also present. With the advent of improved magnification there are reports of multiple root canals in the maxillary first molars. Nonsurgical endodontic therapy of a left maxillary first molar with three roots and seven root canals was successfully performed under a dental operating microscope. The diagnosis of multiple root canals was confirmed with the help of Cone Beam Computed Tomography (CBCT) images. PMID:25565745

  7. The role of computer-aided 3D surgery and stereolithographic modelling for vector orientation in premaxillary and trans-sinusoidal maxillary distraction osteogenesis.

    PubMed

    Varol, Altan; Basa, Selçuk

    2009-06-01

    Maxillary distraction osteogenesis is a challenging procedure when it is performed with internal submerged distractors due to obligation of setting accurate distraction vectors. Five patients with severe maxillary retrognathy were planned with Mimics 10.01 CMF and Simplant 10.01 software. Distraction vectors and rods of distractors were arranged in 3D environment and on STL models. All patients were operated under general anaesthesia and complete Le Fort I downfracture was performed. All distractions were performed according to orientated vectors. All patients achieved stable occlusion and satisfactory aesthetic outcome at the end of the treatment period. Preoperative bending of internal maxillary distractors prevents significant loss of operation time. 3D computer-aided surgical simulation and model surgery provide accurate orientation of distraction vectors for premaxillary and internal trans-sinusoidal maxillary distraction. Combination of virtual surgical simulation and stereolithographic models surgery can be validated as an effective method of preoperative planning for complicated maxillofacial surgery cases.

  8. Denture labeling: A new approach

    PubMed Central

    Bansal, Pardeep K.; Sharma, Akshey; Bhanot, Rajesh

    2011-01-01

    The need for denture labeling is important for forensic and social reasons in case patients need to be identified individually. The importance of denture marking has long been acknowledged by the dental profession. Over the years, various denture marking systems have been reported in the literature, but none till date fulfills all the prescribed ADA specifications. A simple, easy, inexpensive procedure for marking accurate identification marks on dentures with a lead foil is described here. The label caring the patient information is incorporated in the acrylic resin during the denture processing. PMID:21957379

  9. Six-year clinical outcome of single implant-retained mandibular overdentures--a pilot study.

    PubMed

    Passia, Nicole; Wolfart, Stefan; Kern, Matthias

    2015-10-01

    The aim of this prospective pilot study was to evaluate the prosthodontic maintenance as well as the implant outcome of single implant-retained mandibular overdentures over an observation period of 6 years. Eleven edentulous patients received one single implant in the midline of the mandible. Denture bases were temporarily relined and 2 months later provided with a ball attachment for implant retention. Implant related parameters and prosthodontic maintenance interventions were assessed 4 weeks after implant loading and then once a year. Over a mean observation period of 75.9 months, no implant was lost. The most frequent prosthetic maintenance intervention was activation of the matrix due to loss of retention, followed by exchange of the female part. Eight denture bases had to be repaired after a fracture in the midline area. Within the limitations of this preliminary clinical study, the concept of a single midline implant to retain a mandibular complete denture was a successful treatment option for elderly edentulous patients. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Dental Training Films.

    ERIC Educational Resources Information Center

    Veterans Administration Medical Center, Washington, DC.

    This dental training films catalog is organized into two sections. Section I is a category listing of the films by number and title, indexed according to generalized headings; categories are as follow: anatomy, articulator systems, complete dentures, dental assisting, dental laboratory technology, dental materials, dental office emergencies,…

  11. The effect of denture adhesives on Candida albicans growth in vitro.

    PubMed

    Sampaio-Maia, Benedita; Figueiral, Maria Helena; Sousa-Rodrigues, Patricia; Fernandes, Maria Helena; Scully, Crispian

    2012-06-01

    Denture-wearing favours the growth of Candida. In view of the fact that many denture wearers regularly use adhesives to enhance denture retention, stability and function, the aim of this work was to study the effect of denture adhesives on Candida albicans growth in vitro. The denture adhesives tested were Corega(®) cream, Kukident(®) cream, Novafix(®) cream, Polident(®) cream, Protefix(®) cream, Steradent(®) cream, Aderyn(®) powder, Corega(®) ultra powder, Protefix(®) powder and Corega(®) strip. C. albicans growth curves were obtained in the presence or absence of a 1% solution of the denture adhesive diluted in Sabouraud broth. Macro- and microscopic morphological changes in C. albicans were analysed, as was microbial contamination of the denture adhesive. Most of the denture adhesives studied induced morphological changes in C. albicans cells and colonies, but only two had any significant inhibitory effect on yeast growth. Kukident(®) cream markedly inhibited C. albicans growth in a concentration-dependent way, reducing the growth rate by 95%, whereas Corega(®) cream also inhibited C. albicans growth but in a non-concentration-dependent way, reducing the growth rate by 37%. In addition, denture adhesives available as powders had detectable microbial contamination. Some commercially available denture adhesives showed microbial contamination and some had significant inhibitory effect on C. albicans growth. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  12. Analysis of the dentoalveolar effects of slow and rapid maxillary expansion in complete bilateral cleft lip and palate patients: a randomized clinical trial.

    PubMed

    de Medeiros Alves, Arthur César; Garib, Daniela Gamba; Janson, Guilherme; de Almeida, Araci Malagodi; Calil, Louise Resti

    2016-09-01

    The purpose of this study was to compare the dentoalveolar effects of slow (SME) and rapid (RME) maxillary expansions in patients with complete bilateral cleft lip and palate (BCLP). A sample of 50 patients with BCLP and maxillary arch constriction was randomly and equally allocated into two groups. Group SME comprised patients (mean age of 8.8 years) treated with quad-helix appliance. Group RME comprised individuals (mean age of 8.9 years) treated with Hyrax expander. Digital dental models obtained immediately pre-expansion (T1) and 6 months after the active expansion period (T2) were used for measuring maxillary dental arch widths, arch perimeter, arch length, palatal depth, buccolingual inclination of posterior teeth and differential amount of expansion accomplished at the canine and molar regions. Inter-phase and intergroup comparisons were performed using paired t tests and t tests, respectively (p < 0.05). SME and RME caused significant increase of arch widths and arch perimeter. Arch length and palatal depth decreased nonsignificantly with SME but significantly with RME. Buccal tooth inclination was significant only for maxillary deciduous canines in both groups. The quad-helix appliance showed a significant differential expansion between anterior and posterior regions. No differences were observed between SME and RME for all variables. Differences were not found between the dentoalveolar effects of SME and RME in patients with BCLP. SME demanded a greater therapy time compared to RME. Both expansion procedures can be similarly indicated to correct maxillary arch constriction in patients with BCLP in the mixed dentition.

  13. EAO consensus conference: economic evaluation of implant-supported prostheses.

    PubMed

    Beikler, Thomas; Flemmig, Thomas F

    2015-09-01

    There are various alternatives for the management of oral conditions that may lead to or already have lead to partial or full edentulism. Economic evaluations measure the efficiency of alternative healthcare interventions and provide useful information for decision-making and the allocation of scarce resources. The current English literature dealing with "cost-effectiveness" of dental implant therapy versus different alternative treatment modalities, that is, complete and fixed partial dentures, root canal, and periodontal treatment, has been included in this narrative review. Due to the high heterogeneity within the literature, a meta-analysis could not be conducted. The available evidence from economic evaluations indicated that for the treatment of central incisors with irreversible pulpitis and coronal lesions, root canal treatments were most cost-effective initial treatment options. When initial root canal treatments failed, orthograde retreatments were most cost-effective. When root canal retreatments failed, extractions and replacement with single implant-supported crowns were more cost-effective compared to fixed or removable partial dentures. In the treatment of periodontitis in molars with Class I furcation invasion, non-surgical periodontal therapy was more effective and costed less than implant-supported single crowns. For the replacement of single missing teeth, two evaluations indicated that implant-supported single crowns provided better outcomes in terms of greater quality-adjusted tooth years or survival rates at lower costs compared to fixed partial prostheses. Another economic evaluation found that implant-supported crowns costed more, but provided greater survival rates compared to fixed partial dentures. For the restoration of edentulous mandibles, two evaluations indicated that overdentures retained by two or four implants improved oral health-related quality of life outcomes, but costed more than complete dentures. To better assess the efficiency of implant-supported prostheses in various clinical conditions, more economic evaluations are needed that follow well-established methodologies in health economics. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Masticatory performance and oral health-related quality of life before and after complete denture treatment.

    PubMed

    Yamamoto, Saori; Shiga, Hiroshi

    2018-03-13

    To clarify the relationship between masticatory performance and oral health-related quality of life (OHRQoL) before and after complete denture treatment. Thirty patients wearing complete dentures were asked to chew a gummy jelly on their habitual chewing side, and the amount of glucose extraction during chewing was measured as the parameter of masticatory performance. Subjects were asked to answer the Oral Health Impact Profile (OHIP-J49) questionnaire, which consists of 49 questions related to oral problems. The total score of 49 question items along with individual domain scores within the seven domains (functional limitation, pain, psychological discomfort, physical disability, psychological disability, social disability and handicap) were calculated and used as the parameters of OHRQoL. These records were obtained before treatment and 3 months after treatment. Each parameter of masticatory performance and OHRQoL was compared before treatment and after treatment. The relationship between masticatory performance and OHRQoL was investigated, and a stepwise multiple linear regression analysis was performed. Both masticatory performance and OHRQoL were significantly improved after treatment. Furthermore, masticatory performance was significantly correlated with some parameters of OHRQoL. The stepwise multiple linear regression analysis showed functional limitation and pain as important factors affecting masticatory performance before treatment and functional limitation as important factors affecting masticatory performance after treatment. These results suggested that masticatory performance and OHRQoL are significantly improved after treatment and that there is a close relationship between the two. Moreover, functional limitation was found to be the most important factor affecting masticatory performance. Copyright © 2018 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  15. Standard of disocclusion in complete dentures supported by implants without free distal ends: analysis by the finite elements method

    PubMed Central

    GRECO, Gustavo Diniz; de LAS CASAS, Estevam Barbosa; CORNACCHIA, Tulimar P. Machado; de MAGALHÃES, Cláudia Silami; MOREIRA, Allyson Nogueira

    2012-01-01

    Objective The occlusal patterns are key requirements for the clinical success of oral rehabilitation supported by implants. This study compared the stresses generated by the disocclusion in the canine guide occlusion (CGO) and bilateral balanced occlusion (BBO) on the implants and metallic infrastructure of a complete Brånemark protocol-type denture modified with the inclusion of one posterior short implant on each side. Material and Methods A three-dimensional model simulated a mandible with seven titanium implants as pillars, five of them installed between the mental foramen and the two posterior implants, located at the midpoint of the occlusal surface of the first molar. A load of 15 N with an angle of 45º was applied to a tooth or distributed across three teeth to simulate the CGO or BBO, respectively. The commercial program ABAQUS® was used for the model development, before and after the processing of the data. The results were based on a linear static analysis and were used to compare the magnitude of the equivalent stress for each of the simulations. Results The results showed that the disocclusion in CGO generated higher stresses concentrated on the working side in the region of the short implant. In BBO, the stresses were less intense and more evenly distributed on the prosthesis. The maximum stress found in the simulation of the disocclusion in CGO was two times higher than that found in the simulation of the BBO. The point of maximum stress was located in the neck of the short implant on the working side. Conclusions Under the conditions of this study, it was concluded that the BBO pattern was more suitable than CGO for the lower complete denture supported by implants without free distal ends. PMID:22437680

  16. Poly(methyl methacrylate) with TiO2 nanoparticles inclusion for stereolitographic complete denture manufacturing - the fututre in dental care for elderly edentulous patients?

    PubMed

    Totu, Eugenia Eftimie; Nechifor, Aurelia Cristina; Nechifor, Gheorghe; Aboul-Enein, Hassan Y; Cristache, Corina Marilena

    2017-04-01

    The aim of this study was to obtain a Poly(methylmethacrylate) (PMMA)-TiO 2 nanocomposite material with improved antibacterial characteristics, suitable for manufacturing 3D printed dental prosthesis. 0.2, 0.4, 0.6, 1, 2.5 by weight% of TiO 2 nanoparticles have been added to the commercially available stereolithographic PMMA material and the obtained nanocomposites have been analyzed using FTIR, SEM and also tested for antimicrobial efficacy against bacterial cultures from Candida species (C. scotti). SEM images and EDX results highlighted the presence of TiO 2 in PMMA nanocomposites. The elemental composition (EDX) also showed the presence of other fillers included in stereolithographic PMMA solution. FTIR analysis clearly revealed changes in polymeric matrix structure when adding TiO 2 nanoparticles. Sample containing 0.4, 1 and 2.5wt% TiO 2 nanoparticles inhibited the growth of Candida scotti strain in standard conditions according to the toxicity control method (DHA). Increasing quantity of nano-titania has resulted in particles fooling, forming new aggregates instead of the homogenous dispersion of nanoparticles with modified viscosity characteristics and expected lower mechanical parameters. Significant improvements in polymer characteristics and nice dispersion of the TiO 2 nanoparticles have been noticed for 0.4wt%, therefore it was used for stereolitographic complete denture prototyping. Incorporation of TiO 2 nanoparticles in PMMA polymer matrix was proved to have antibacterial effects, specifically on Candida species. The newly obtained 0.4% nanocomposite was successfully used with stereolitographic technique for complete denture manufacturing. However, mechanical and biocompatibility tests need to be performed in order to extend the clinical usage. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Evaluation of cleansing methods for previously worn prostheses.

    PubMed

    Glass, R Thomas; Conrad, Robert S; Bullard, James W; Goodson, Leigh B; Mehta, Naresh; Lech, Stanley J; Loewy, Zvi G

    2011-04-01

    Although there are many product claims that address the issue of denture sanitization, controlled scientific studies on previously worn dentures have not been performed. The purpose of this study was to evaluate procedures directed at sanitizing previously worn contaminated dentures from two regions of the United States. This study examined 51 previously worn dentures from two regions. An established method of denture retrieval, sectioning, and culturing was used, including isolation of anaerobes. Evaluation of microbial contamination posttreatment was used to determine the effects of soaking dentures in Polident (US and European formulations) for varying periods of times/temperatures, microwaving dentures with varying temperatures, sonicating dentures, and immersing the dentures while using a vacuum. A combination of analysis of variance (ANOVA) and general linear model (GLM) of the SPSS was used to analyze the data with P < .05 being considered statistically significant when using a two-tailed test. While all Polident treatments were found to significantly reduce microorganism loads in dentures, extended soaking (8 hours) and 65 degrees C (5 minutes) were the most effective. Microwaving was slightly more effective than either sonication or vacuum. Regardless the treatment, dentures underwent sanitization rather than sterilization. Denture-borne microorganisms can be significantly reduced by using a Polident solution for 8 hours at room temperature or for 5 minutes at 65 degrees C. Microwaving, sonication, and use of a vacuum were less effective. ClLINICAL IMPLICATIONS The importance of daily use of Polident solution for 8 hours or for 5 minutes at 65 degrees C to sanitize worn prostheses must be stressed.

  18. [Development of visible-light cured FRP denture].

    PubMed

    Yu, P Y

    1990-06-01

    Acrylic denture may be fractured easily because it has a relatively poor resistance to stresses of impact, and the thick acrylic denture base also uncomforted to denture wearers. In this study, for improvement of the mechanical properties, the FRP is applied to the denture base, and try to make a thin denture base. Using the visible light-curing system, the laboratory fabrication time is saved dramatically. To develop the visible light-cured FRP denture base, with various combination of matrix resins and reinforcements, the physical properties of FRP plates were investigated first. From the results of the bending test, hardness test, and manipulation considering, the sateen weave's glasscloth was choose as the reinforcement of the prepreg. The matrix resin of Bis-GMA/UDMA/3G at 48/48/4 wt% was determined. The 3 plies glasscloth included FRP plate is 0.8 mm thickness has the maximum bending strength about 50 kgf/mm2, which is about 5 times larger than that of acrylic resin. Succeeding the study of above, the FRP denture base was fabricated by using the 0.8 mm thickness 3 plies included prepreg. This repreg is manufactured in sheet form beforehand, which is ease to manipulate at laboratory. By using the visible light curing system, it is only taken 10 min. to make a FRP denture base. The following procedures of fabricating a FRP denture is the same as metalplate denture. The visible-light cured FRP denture has some advantages such as accuracy of fit, ease of fabrication and manipulation, and only 0.8 mm thickness but has superior strength.

  19. Analysis of the effectiveness of different hygiene procedures used in dental prostheses.

    PubMed

    Rossato, Marisa Bagiotto; Unfer, Beatriz; May, Lilana Gressler; Braun, Katia Olmedo

    2011-01-01

    To compare the effectiveness of bacterial plaque removal of six denture hygiene procedures used by patients to clean their dentures. Fifteen students randomly divided into groups G1, G2, G3, G4, G5 and G6 used maxillary intraoral appliances for 24 h without cleaning them. Afterwards, the appliances were submitted to the following procedures: P1: washing under running water for 20 s; P2 and P3: cleaning with alkaline peroxide (Corega Tabs®) for 5 and 30 min, respectively; P4: brushing with water and liquid soap for 40 s; P5: alkaline hypochlorite for 10 minutes; P6: home use chlorine solution (Q'boa® at 0.45% for 10 min), throughout a period of 6 consecutive weeks. The procedures followed a circulating scheme, so that all the appliances were submitted to all the hygiene methods studied. After the hygiene procedures, the appliances were stained, photographed and submitted to the weighing method. After ANOVA and Tukey's test, differences were observed: P5 = 0.73 ± 0.3 (b), P6 = 1.27 ± 0.4(b,c), P4 = 1.92 ± 0.5 (b,c), P3 = 2.24 ± 1.0 (b,c), P2 = 7.53 ± 2.5 (c) and P1 = 26.86 ± 15. 3 (a). From the results of the study, it could be concluded that the use of alkaline hypochlorite is the best way to remove bacterial plaque, followed by the home-use chlorine solution and brushing with water and liquid soap. Corega Tabs® must be used for 30 min of immersion to have a cleaning effectiveness similar to that of alkaline hypochlorite.

  20. Pressure dynamics in the trays caused by differences of the various impression materials and thickness of the relief in the maxillary edentulous model.

    PubMed

    Iwasaki, Masatoshi; Kawara, Misao; Inoue, Sayumi; Komiyama, Osamu; Iida, Takashi; Asano, Takashi

    2016-04-01

    The purpose of this study is to compare the pressure dynamics in the trays caused by differences in the various impression materials and in the thickness of the relief provided for the trays. In this study, two types of polyvinylsiloxane elastomers, one type of polyether elastomer and one type of alginate impression material were used. Pressure sensors were embedded at eight locations in a model of an edentulous maxilla, and used a simulation model covered with a pseudomucosa. For each impression material, the measurement was performed five times for each of the three types of trays, and the mean values were determined. Statistical analysis was carried out using one-way analysis of variance and the Tukey's HDS method, and the various pressure sensor values for each of the impression materials were compared 10s and 20s after the start of the measurement. Additionally, we compared differences among the three types of trays after 20s. The pressure values for sensors placed in the relief region tended to become uniform. Furthermore, we saw a tendency for the pressure to increase at the alveolar crests of the first molars on the left and right and at the posterior border of the palate, all of which support the denture, when relief was provided. The above results suggest that making the final impression for the denture using the selective pressure technique, with consideration given to the pressure dynamic, may lead to a good outcome in terms of preservation of the alveolar ridge. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  1. [Guywire dentures].

    PubMed

    Riakhovskiĭ, A N

    2000-01-01

    Analyzes possible complications and shortcomings of traditional prosthetic treatments. Presents a new approach to prosthetic treatment and describes the general design of guy dentures. Describes in brief the biomechanics, methods of making guy dentures, and discusses their advantages in comparison with the traditional dentures.

  2. A 3-year prospective clinical study of telescopic crown, bar, and locator attachments for removable four implant-supported maxillary overdentures.

    PubMed

    Zou, Duohong; Wu, Yiqun; Huang, Wei; Wang, Feng; Wang, Shen; Zhang, Zhiyong; Zhang, Zhiyuan

    2013-01-01

    To evaluate telescopic crown (TC), bar, and locator attachments used in removable four implant-supported overdentures for patients with edentulous maxillae. A total of 30 maxillary edentulous patients were enrolled in a 3-year prospective study. Ten patients (group A) were treated with overdentures supported by TCs, 10 patients (group B) with overdentures supported by bar attachments, and 10 patients (group C) with overdentures supported by locator attachments. A total of 120 implants were used to restore oral function. During the 3-year follow-up period, implant survival and success rates, biologic and mechanical complications, prosthodontic maintenance efforts, and patient satisfaction were evaluated. All 30 patients were available for the 3-year follow-up and exhibited 100% implant survival and success rates. Peri-implant marginal bone resorption was not statistically significant for the three groups. There were lower plaque, bleeding, gingiva, and calculus indices in group C compared with groups A and B. The number of prosthodontic maintenance visits revealed eight complications in the TC group, seven complications in the bar group, and four complications in the locator group. However, there were no differences in the clinical effects of the overdentures in the three groups. Within the limits of this prospective study, it was concluded that the locator system produced superior clinical results compared with the TC and bar attachments in terms of peri-implant hygiene parameters, the frequency of prosthodontic maintenance measures, cost, and ease of denture preparation. However, longer-term prospective studies are required to confirm these results.

  3. Finite element analysis of stress-breaking attachments on maxillary implant-retained overdentures.

    PubMed

    Tanino, Fuminori; Hayakawa, Iwao; Hirano, Shigezo; Minakuchi, Shunsuke

    2007-01-01

    The purpose of this study was to examine the effect of stress-breaking attachments at the connections between maxillary palateless overdentures and implants. Three-dimensional finite element models were used to reproduce an edentulous human maxilla with an implant-retained overdenture. Two-implant models (in the canine tooth positions on both sides) and four-implant models (in the canine and second premolar tooth positions on both sides) were examined. Stress-breaking material connecting the implants and denture was included around each abutment. Axial loads of 100 N were applied to the occlusal surface at the left first molar tooth positions. In each model, the influence of the stress-breaking attachments was compared by changing the elastic modulus from 1 to 3,000 MPa and the thickness of the stress-breaking material from 1 to 3 mm. Maximum stress at the implant-bone interface and stress at the cortical bone surface just under the loading point were calculated. In all models, maximum stress at the implant-bone interface with implants located in the canine tooth position was generated at the peri-implant bone on the loading side. As the elastic modulus of the stress-breaking materials increased, the stress increased at the implant-bone interface and decreased at the cortical bone surface. Moreover, stress at the implant-bone interface with 3-mm-thick stress-breaking material was smaller than that with 1-mm-thick material. Within the limitations of this experiment, stress generated at the implant-bone interface could be controlled by altering the elastic modulus and thickness of the stress-breaking materials.

  4. Candida albicans importance to denture wearers. A literature review.

    PubMed

    Gleiznys, Alvydas; Zdanavičienė, Eglė; Žilinskas, Juozas

    2015-01-01

    Opportunistic oral fungal infections have spred, especially in denture wearers. Denture stomatitis is a common inflammatory reaction, multifactorial etiology, which is usually associated with Candida species, particularly Candida albicans, due to its high virulence, ability to adhere and form biofilms on oral cavity tissues and denture surfaces. This article highlights the pathogenesis, clinical presentation, and management strategies of Candida-associated denture stomatitis commonly encountered in dental practice.

  5. Preoperative Cleft Lip Measurements and Maxillary Growth in Patients With Unilateral Cleft Lip and Palate.

    PubMed

    Antonarakis, Gregory S; Tompson, Bryan D; Fisher, David M

    2016-11-01

    Maxillary growth in patients with cleft lip and palate is highly variable. The authors' aim was to investigate associations between preoperative cleft lip measurements and maxillary growth determined cephalometrically in patients with complete unilateral cleft lip and palate (cUCLP). Retrospective cross-sectional study. Children with cUCLP. Preoperative cleft lip measurements were made at the time of primary cheiloplasty and available for each patient. Maxillary growth was evaluated on lateral cephalometric radiographs taken prior to any orthodontic treatment and alveolar bone grafting (8.5 ± 0.7 years). The presence of associations between preoperative cleft lip measurements and cephalometric measures of maxillary growth was determined using regression analyses. In the 58 patients included in the study, the cleft lateral lip element was deficient in height in 90% and in transverse width in 81% of patients. There was an inverse correlation between cleft lateral lip height and transverse width with a β coefficient of -0.382 (P = .003). Patients with a more deficient cleft lateral lip height displayed a shorter maxillary length (β coefficient = 0.336; P = .010), a less protruded maxilla (β coefficient = .334; P = .008), and a shorter anterior maxillary height (β coefficient = 0.306; P = .020) than those with a less deficient cleft lateral lip height. Patients with cUCLP present with varying degrees of lateral lip hypoplasia. Preoperative measures of lateral lip deficiency are related to later observed deficiencies of maxillary length, protrusion, and height.

  6. Development of a Contemporary Animal Model of Candida albicans-Associated Denture Stomatitis Using a Novel Intraoral Denture System

    PubMed Central

    Johnson, Clorinda C.; Yu, Alika; Lee, Heeje; Fidel, Paul L.

    2012-01-01

    Denture stomatitis (DS) is a fungal infection characterized by inflammation of the oral mucosa in direct contact with the denture and affects up to 50% of denture wearers. Despite the prevalence, very little is known about the role of fungal or host factors that contribute to pathogenesis. Recently, we developed a novel intraoral denture system for rodent research. This denture system consists of custom-fitted fixed and removable parts to allow repeated sampling and longitudinal studies. The purpose of this study was to use this denture system to develop a clinically relevant animal model of DS. To establish DS, rats were inoculated with pelleted Candida albicans, which resulted in sustained colonization of the denture and palate for 8 weeks postinoculation. Biofilm formation on the denture was observed by week 4 and on the palate by week 6 postinoculation. Rats were monitored for clinical signs of disease by assigning a clinical score after macroscopic examination of the palate tissue according to Newton's method. By week 4 postinoculation, the majority of inoculated rats with dentures exhibited a clinical score of 1 (pinpoint erythema). By week 6 and week 8 postinoculation, increasing percentages of rats exhibited a clinical score of 2 (diffuse erythema/edema). Histological analysis of palate tissue demonstrated progressively increasing inflammatory cell recruitment throughout the time course of the infection. Palatal biofilm formation was commensurate with development of palatal erythema, which suggests a role for biofilm in the inflammatory response. PMID:22392931

  7. 21 CFR 872.3420 - Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... polyacrylamide polymer denture adhesive. 872.3420 Section 872.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION....3420 Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive. (a) Identification. A carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive is a device...

  8. 21 CFR 872.3420 - Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... polyacrylamide polymer denture adhesive. 872.3420 Section 872.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION....3420 Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive. (a) Identification. A carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive is a device...

  9. 21 CFR 872.3420 - Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... polyacrylamide polymer denture adhesive. 872.3420 Section 872.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION....3420 Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive. (a) Identification. A carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive is a device...

  10. 21 CFR 872.3420 - Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... polyacrylamide polymer denture adhesive. 872.3420 Section 872.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION....3420 Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive. (a) Identification. A carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive is a device...

  11. 21 CFR 872.3420 - Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... polyacrylamide polymer denture adhesive. 872.3420 Section 872.3420 Food and Drugs FOOD AND DRUG ADMINISTRATION....3420 Carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive. (a) Identification. A carboxymethylcellulose sodium and cationic polyacrylamide polymer denture adhesive is a device...

  12. Orthodontic Management with Traction and Asymmetric Extraction for Multiple Impacted Permanent Maxillary Teeth - A Case Report.

    PubMed

    Niu, Qiannan; Zhang, Liang; Dai, Juan; Li, Feifei; Feng, Xue

    2016-01-01

    Multiple impacted teeth are a rare eruption disturbance that increases the case complexity. In this article, we described a 13-year-old boy whose 5 permanent maxillary teeth were not erupted although their root formation was complete. The orthodontic treatment with traction and asymmetric extraction was performed to achieve a significantly improved functional and esthetic result.

  13. Denture hyperplasia with areas simulating oral inverted ductal papilloma.

    PubMed

    Vargas, Pablo Agustin; Perez, Danyel Elias da Cruz; Jorge, Jacks; Rangel, Ana Lúcia Carrinho Ayrosa; León, Jorge Esquiche; Almeida, Oslei Paes de

    2005-07-01

    Denture hyperplasia is a reactive lesion of the oral mucosa, usually associated to an ill-fitting denture. This lesion is easily diagnosed and in some cases distinct microscopic variations such as osseous, oncocytic and squamous metaplasia may be found. These metaplastic alterations probably are associated with the lymphocytic infiltrate usually present in denture hyperplasia. We present a case of denture hyperplasia containing salivary gland tissue with ductal alterations mimicking an oral inverted ductal papilloma.

  14. 21 CFR 872.3480 - Polyacrylamide polymer (modified cationic) denture adhesive.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Polyacrylamide polymer (modified cationic) denture... polymer (modified cationic) denture adhesive. (a) Identification. A polyacrylamide polymer (modified cationic) denture adhesive is a device composed of polyacrylamide polymer (modified cationic) intended to...

  15. 21 CFR 872.3480 - Polyacrylamide polymer (modified cationic) denture adhesive.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Polyacrylamide polymer (modified cationic) denture... polymer (modified cationic) denture adhesive. (a) Identification. A polyacrylamide polymer (modified cationic) denture adhesive is a device composed of polyacrylamide polymer (modified cationic) intended to...

  16. 21 CFR 872.3480 - Polyacrylamide polymer (modified cationic) denture adhesive.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Polyacrylamide polymer (modified cationic) denture... polymer (modified cationic) denture adhesive. (a) Identification. A polyacrylamide polymer (modified cationic) denture adhesive is a device composed of polyacrylamide polymer (modified cationic) intended to...

  17. 21 CFR 872.3480 - Polyacrylamide polymer (modified cationic) denture adhesive.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Polyacrylamide polymer (modified cationic) denture... polymer (modified cationic) denture adhesive. (a) Identification. A polyacrylamide polymer (modified cationic) denture adhesive is a device composed of polyacrylamide polymer (modified cationic) intended to...

  18. 21 CFR 872.3480 - Polyacrylamide polymer (modified cationic) denture adhesive.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Polyacrylamide polymer (modified cationic) denture... polymer (modified cationic) denture adhesive. (a) Identification. A polyacrylamide polymer (modified cationic) denture adhesive is a device composed of polyacrylamide polymer (modified cationic) intended to...

  19. Evaluation of gloss changes of two denture acrylic resin materials in four different beverages.

    PubMed

    Keyf, Filiz; Etikan, Ilker

    2004-03-01

    The primary disadvantages of the materials which are used in construction of complete and removable partial dentures is that their esthetic, physical and mechanical properties change rapidly with time in the oral environment. For esthetics, color stability is one of the criteria that needs careful attention. Color may provide important information on the serviceability of these materials. Color change affects the gloss of these materials. The objective of the present study was to determine the gloss changes resulting from the testing process in four different beverages in one heat-polymerized denture base resin and one cold-polymerized denture base repair resin. Thirty-six samples were fabricated for each material. Each sample had a smooth polished and a rough unpolished surface. The gloss measurements were made with a glossmeter before testing. Four different beverages (tea, coffee, cola and cherry juice) were used for testing. Two angles of illumination (20 and 60 degrees) were used for the gloss measurements. The samples were immersed in water, tea, coffee, cola and cherry juice solutions. The gloss of the samples was measured again with the glossmeter at the end of the 45th day and 135th day of testing. The arithmetic mean and standard deviation of each of the samples were calculated and compared with each other statistically by using the Wilcoxon test (within times) (p < or = 0.05 significant), the Kruskal-Wallis analysis of variance (p < or = 0.05 significant) and the Mann-Whitney U-test with Bonforoni correction (when the difference between the samples was significant) (p < or = 0.05 significant). The results of this study revealed that gloss changes occurred after testing in heat-polymerized denture base resin and cold-polymerized denture base repair resin. The significance of the gloss changes exhibited by each sample, kept for different lengths of time in the same solution, were compared using the Wilcoxon test. The results were statistically significant (p < or = 0.05). According to the Kruskal-Wallis analysis of variance, the difference between measurements for angles of illumination was statistically significant (p < or = 0.05). Also according to the Mann-Whitney U-test, the difference between two polished surfaces or two unpolished surfaces was statistically insignificant (p > 0.05), but the difference between smooth polished and rough unpolished surfaces was statistically significant (p < or = 0.05). It was found that either the gloss of heat-polymerized denture base resin or the gloss of cold-polymerized denture base repair resin was affected by tested agents, and the four beverages demonstrated noticeable gloss changes. Cherry juice demonstrated the least change, while tea exhibited the greatest change.

  20. Impact of removable partial denture prosthesis on chewing efficiency

    PubMed Central

    BESSADET, Marion; NICOLAS, Emmanuel; SOCHAT, Marine; HENNEQUIN, Martine; VEYRUNE, Jean-Luc

    2013-01-01

    Removable partial denture prostheses are still being used for anatomic, medical and economic reasons. However, the impact on chewing parameters is poorly described. Objectives The objective of this study was to estimate the impact of removable partial denture prosthesis on masticatory parameters. Material and Methods Nineteen removable partial denture prosthesis (RPDP) wearers participated in the study. Among them, 10 subjects were Kennedy Class III partially edentulous and 9 with posterior edentulism (Class I). All presented a complete and full dentate opposing arch. The subjects chewed samples of carrots and peanuts with and without their prosthesis. The granulometry of the expectorated boluses from carrot and peanuts was characterized by median particle size (D50), determined at the natural point of swallowing. Number of chewing cycles (CC), chewing time (CT) and chewing frequency (CF=CC/CT) were video recorded. Results With RPDP, the mean D50 values for carrot and peanuts were lower [Repeated Model Procedures (RMP), F=15, p<0.001] regardless of the type of Kennedy Class. For each food, mean CC, CT and CF values recorded decreased (RMP, F=18, F=9, and F=20 respectively, p<0.01). With or without RPD, the boluses' granulometry values were above the masticatory normative index (MNI) determined as 4,000 µm. Conclusion RPDP rehabilitation improves the ability to reduce the bolus particle size, but does not reestablish fully the masticatory function. Clinical relevance This study encourages the clinical improvement of oral rehabilitation procedure. PMID:24212983

Top