Sample records for maximize statistical power

  1. The power and robustness of maximum LOD score statistics.

    PubMed

    Yoo, Y J; Mendell, N R

    2008-07-01

    The maximum LOD score statistic is extremely powerful for gene mapping when calculated using the correct genetic parameter value. When the mode of genetic transmission is unknown, the maximum of the LOD scores obtained using several genetic parameter values is reported. This latter statistic requires higher critical value than the maximum LOD score statistic calculated from a single genetic parameter value. In this paper, we compare the power of maximum LOD scores based on three fixed sets of genetic parameter values with the power of the LOD score obtained after maximizing over the entire range of genetic parameter values. We simulate family data under nine generating models. For generating models with non-zero phenocopy rates, LOD scores maximized over the entire range of genetic parameters yielded greater power than maximum LOD scores for fixed sets of parameter values with zero phenocopy rates. No maximum LOD score was consistently more powerful than the others for generating models with a zero phenocopy rate. The power loss of the LOD score maximized over the entire range of genetic parameters, relative to the maximum LOD score calculated using the correct genetic parameter value, appeared to be robust to the generating models.

  2. The Relationship Between Maximal Aerobic Power and Recovery in Elite Ice Hockey Players During a Simulated Game.

    PubMed

    Steeves, Darren; Campagna, Phil

    2018-02-14

    This project investigated whether there was a relationship between maximal aerobic power and the recovery or performance in elite ice hockey players during a simulated hockey game. An on-ice protocol was used to simulate a game of ice hockey. Recovery values were determined by the differences in lactate and heart rate measures. Total distance traveled was also recorded as a performance measure. On two other days, subjects returned and completed a maximal aerobic power test on a treadmill and a maximal lactate test on ice. Statistical analysis showed no relationship between maximal aerobic power or maximal lactate values and recovery (heart rate, lactate) or the performance measure of distance traveled. It was concluded there was no relationship between maximal aerobic power and recovery during a simulated game in elite hockey players.

  3. A more powerful exact test of noninferiority from binary matched-pairs data.

    PubMed

    Lloyd, Chris J; Moldovan, Max V

    2008-08-15

    Assessing the therapeutic noninferiority of one medical treatment compared with another is often based on the difference in response rates from a matched binary pairs design. This paper develops a new exact unconditional test for noninferiority that is more powerful than available alternatives. There are two new elements presented in this paper. First, we introduce the likelihood ratio statistic as an alternative to the previously proposed score statistic of Nam (Biometrics 1997; 53:1422-1430). Second, we eliminate the nuisance parameter by estimation followed by maximization as an alternative to the partial maximization of Berger and Boos (Am. Stat. Assoc. 1994; 89:1012-1016) or traditional full maximization. Based on an extensive numerical study, we recommend tests based on the score statistic, the nuisance parameter being controlled by estimation followed by maximization. 2008 John Wiley & Sons, Ltd

  4. From entropy-maximization to equality-maximization: Gauss, Laplace, Pareto, and Subbotin

    NASA Astrophysics Data System (ADS)

    Eliazar, Iddo

    2014-12-01

    The entropy-maximization paradigm of statistical physics is well known to generate the omnipresent Gauss law. In this paper we establish an analogous socioeconomic model which maximizes social equality, rather than physical disorder, in the context of the distributions of income and wealth in human societies. We show that-on a logarithmic scale-the Laplace law is the socioeconomic equality-maximizing counterpart of the physical entropy-maximizing Gauss law, and that this law manifests an optimized balance between two opposing forces: (i) the rich and powerful, striving to amass ever more wealth, and thus to increase social inequality; and (ii) the masses, struggling to form more egalitarian societies, and thus to increase social equality. Our results lead from log-Gauss statistics to log-Laplace statistics, yield Paretian power-law tails of income and wealth distributions, and show how the emergence of a middle-class depends on the underlying levels of socioeconomic inequality and variability. Also, in the context of asset-prices with Laplace-distributed returns, our results imply that financial markets generate an optimized balance between risk and predictability.

  5. A mechanism producing power law etc. distributions

    NASA Astrophysics Data System (ADS)

    Li, Heling; Shen, Hongjun; Yang, Bin

    2017-07-01

    Power law distribution is playing an increasingly important role in the complex system study. Based on the insolvability of complex systems, the idea of incomplete statistics is utilized and expanded, three different exponential factors are introduced in equations about the normalization condition, statistical average and Shannon entropy, with probability distribution function deduced about exponential function, power function and the product form between power function and exponential function derived from Shannon entropy and maximal entropy principle. So it is shown that maximum entropy principle can totally replace equal probability hypothesis. Owing to the fact that power and probability distribution in the product form between power function and exponential function, which cannot be derived via equal probability hypothesis, can be derived by the aid of maximal entropy principle, it also can be concluded that maximal entropy principle is a basic principle which embodies concepts more extensively and reveals basic principles on motion laws of objects more fundamentally. At the same time, this principle also reveals the intrinsic link between Nature and different objects in human society and principles complied by all.

  6. On the fractal characterization of Paretian Poisson processes

    NASA Astrophysics Data System (ADS)

    Eliazar, Iddo I.; Sokolov, Igor M.

    2012-06-01

    Paretian Poisson processes are Poisson processes which are defined on the positive half-line, have maximal points, and are quantified by power-law intensities. Paretian Poisson processes are elemental in statistical physics, and are the bedrock of a host of power-law statistics ranging from Pareto's law to anomalous diffusion. In this paper we establish evenness-based fractal characterizations of Paretian Poisson processes. Considering an array of socioeconomic evenness-based measures of statistical heterogeneity, we show that: amongst the realm of Poisson processes which are defined on the positive half-line, and have maximal points, Paretian Poisson processes are the unique class of 'fractal processes' exhibiting scale-invariance. The results established in this paper are diametric to previous results asserting that the scale-invariance of Poisson processes-with respect to physical randomness-based measures of statistical heterogeneity-is characterized by exponential Poissonian intensities.

  7. Age-Associated Changes in the Spectral and Statistical Parameters of Surface Electromyogram of Tibialis Anterior.

    PubMed

    Siddiqi, Ariba; Arjunan, Sridhar Poosapadi; Kumar, Dinesh Kant

    2016-01-01

    Age-related neuromuscular change of Tibialis Anterior (TA) is a leading cause of muscle strength decline among the elderly. This study has established the baseline for age-associated changes in sEMG of TA at different levels of voluntary contraction. We have investigated the use of Gaussianity and maximal power of the power spectral density (PSD) as suitable features to identify age-associated changes in the surface electromyogram (sEMG). Eighteen younger (20-30 years) and 18 older (60-85 years) cohorts completed two trials of isometric dorsiflexion at four different force levels between 10% and 50% of the maximal voluntary contraction. Gaussianity and maximal power of the PSD of sEMG were determined. Results show a significant increase in sEMG's maximal power of the PSD and Gaussianity with increase in force for both cohorts. It was also observed that older cohorts had higher maximal power of the PSD and lower Gaussianity. These age-related differences observed in the PSD and Gaussianity could be due to motor unit remodelling. This can be useful for noninvasive tracking of age-associated neuromuscular changes.

  8. Age-Associated Changes in the Spectral and Statistical Parameters of Surface Electromyogram of Tibialis Anterior

    PubMed Central

    2016-01-01

    Age-related neuromuscular change of Tibialis Anterior (TA) is a leading cause of muscle strength decline among the elderly. This study has established the baseline for age-associated changes in sEMG of TA at different levels of voluntary contraction. We have investigated the use of Gaussianity and maximal power of the power spectral density (PSD) as suitable features to identify age-associated changes in the surface electromyogram (sEMG). Eighteen younger (20–30 years) and 18 older (60–85 years) cohorts completed two trials of isometric dorsiflexion at four different force levels between 10% and 50% of the maximal voluntary contraction. Gaussianity and maximal power of the PSD of sEMG were determined. Results show a significant increase in sEMG's maximal power of the PSD and Gaussianity with increase in force for both cohorts. It was also observed that older cohorts had higher maximal power of the PSD and lower Gaussianity. These age-related differences observed in the PSD and Gaussianity could be due to motor unit remodelling. This can be useful for noninvasive tracking of age-associated neuromuscular changes. PMID:27610379

  9. A cross-sectional lower-body power profile of elite and subelite Australian football players.

    PubMed

    Caia, Johnpaul; Doyle, Tim L A; Benson, Amanda C

    2013-10-01

    Australian football (AF) is a sport which requires a vast array of physiological qualities, including high levels of strength and power. However, the power characteristics of AF players, particularly at the subelite level have not been extensively studied with further investigation warranted to understand the power capabilities and training requirements of elite and subelite AF groups. Therefore, the aim of this investigation was to develop a lower-body power profile of elite and subelite AF players. Eighteen elite and 12 subelite AF players completed a 1 repetition maximum (1RM) squat test to determine maximal lower-body strength, and countermovement jump (CMJ) and squat jump (SJ) testing to assess lower-body muscular power performance. Maximal lower-body strength was not statistically different between groups (p > 0.05). Elite players produced greater levels of peak power for CMJ at loads of 0, 30 (p < 0.05), and 40% (p < 0.01) of 1RM in comparison to subelite players. Squat jump peak power was statistically different between groups at 0, 20, 30, and 40% (p < 0.01) of 1RM; with elite players producing greater power than their subelite counterparts at all measured loads for SJ. Findings from this investigation demonstrate that elite AF players are able to generate greater levels of lower-body power than subelite AF players, despite no significant differences existing in maximal lower-body strength or body mass. As lower-body power levels clearly differentiate elite and subelite AF players, emphasis may be placed on improving the power levels of subelite players, particularly those aspiring to reach the elite level.

  10. Cross-layer Joint Relay Selection and Power Allocation Scheme for Cooperative Relaying System

    NASA Astrophysics Data System (ADS)

    Zhi, Hui; He, Mengmeng; Wang, Feiyue; Huang, Ziju

    2018-03-01

    A novel cross-layer joint relay selection and power allocation (CL-JRSPA) scheme over physical layer and data-link layer is proposed for cooperative relaying system in this paper. Our goal is finding the optimal relay selection and power allocation scheme to maximize system achievable rate when satisfying total transmit power constraint in physical layer and statistical delay quality-of-service (QoS) demand in data-link layer. Using the concept of effective capacity (EC), our goal can be formulated into an optimal joint relay selection and power allocation (JRSPA) problem to maximize the EC when satisfying total transmit power limitation. We first solving optimal power allocation (PA) problem with Lagrange multiplier approach, and then solving optimal relay selection (RS) problem. Simulation results demonstrate that CL-JRSPA scheme gets larger EC than other schemes when satisfying delay QoS demand. In addition, the proposed CL-JRSPA scheme achieves the maximal EC when relay located approximately halfway between source and destination, and EC becomes smaller when the QoS exponent becomes larger.

  11. Lower Limb Symmetry: Comparison of Muscular Power Between Dominant and Nondominant Legs in Healthy Young Adults Associated With Single-Leg-Dominant Sports.

    PubMed

    Vaisman, Alex; Guiloff, Rodrigo; Rojas, Juan; Delgado, Iris; Figueroa, David; Calvo, Rafael

    2017-12-01

    Achieving a symmetrical power performance (difference <15%) between lower limbs is generally recommended during sports rehabilitation. However, athletes in single-leg-dominant sports, such as professional soccer players, could develop significant asymmetry between their dominant and nondominant legs, such that symmetry does not act as a viable comparison. To (1) compare maximal muscular power between the dominant and nondominant legs in healthy young adults, (2) evaluate the effect of a single-leg-dominant sport activity performed at the professional level, and (3) propose a parameter of normality for maximal power difference in the lower limbs of this young adult population. Controlled laboratory study. A total of 78 healthy, male, young adults were divided into 2 groups according to sport activity level. Group 1 consisted of 51 nonathletes (mean ± SD age, 20.8 ± 1.5 years; weight, 71.9 ± 10.5 kg) who participated in less than 8 hours a week of recreational physical activity with nonspecific training; group 2 consisted of 27 single-leg-dominant professional soccer players (age, 18.4 ± 0.6 years; weight, 70.1 ± 7.5 kg) who specifically trained and competed at their particular activity 8 hours or more a week. For assessment of maximal leg power, both groups completed the single-leg squat jump test. Dominance was determined when participants completed 2 of 3 specific tests with the same extremity. Statistical analysis included the Student t test. No statistical difference was found for maximal power between dominant and nondominant legs for nonathletes ( t = -1.01, P = .316) or single-leg-dominant professional soccer players ( t = -1.10, P = .281). A majority (95%) of participants studied showed a power difference of less than 15% between their lower extremities. Among young healthy adults, symmetrical power performance is expected between lower extremities independent of the existence of dominance and difference in sport activity level. A less than 15% difference in power seems to be a proper parameter to define symmetrical power performance assessed by vertical single-leg jump tests.

  12. A new exact and more powerful unconditional test of no treatment effect from binary matched pairs.

    PubMed

    Lloyd, Chris J

    2008-09-01

    We consider the problem of testing for a difference in the probability of success from matched binary pairs. Starting with three standard inexact tests, the nuisance parameter is first estimated and then the residual dependence is eliminated by maximization, producing what I call an E+M P-value. The E+M P-value based on McNemar's statistic is shown numerically to dominate previous suggestions, including partially maximized P-values as described in Berger and Sidik (2003, Statistical Methods in Medical Research 12, 91-108). The latter method, however, may have computational advantages for large samples.

  13. Linear maps preserving maximal deviation and the Jordan structure of quantum systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hamhalter, Jan

    2012-12-15

    In the algebraic approach to quantum theory, a quantum observable is given by an element of a Jordan algebra and a state of the system is modelled by a normalized positive functional on the underlying algebra. Maximal deviation of a quantum observable is the largest statistical deviation one can obtain in a particular state of the system. The main result of the paper shows that each linear bijective transformation between JBW algebras preserving maximal deviations is formed by a Jordan isomorphism or a minus Jordan isomorphism perturbed by a linear functional multiple of an identity. It shows that only onemore » numerical statistical characteristic has the power to determine the Jordan algebraic structure completely. As a consequence, we obtain that only very special maps can preserve the diameter of the spectra of elements. Nonlinear maps preserving the pseudometric given by maximal deviation are also described. The results generalize hitherto known theorems on preservers of maximal deviation in the case of self-adjoint parts of von Neumann algebras proved by Molnar.« less

  14. Energy Efficiency Optimization in Relay-Assisted MIMO Systems With Perfect and Statistical CSI

    NASA Astrophysics Data System (ADS)

    Zappone, Alessio; Cao, Pan; Jorswieck, Eduard A.

    2014-01-01

    A framework for energy-efficient resource allocation in a single-user, amplify-and-forward relay-assisted MIMO system is devised in this paper. Previous results in this area have focused on rate maximization or sum power minimization problems, whereas fewer results are available when bits/Joule energy efficiency (EE) optimization is the goal. The performance metric to optimize is the ratio between the system's achievable rate and the total consumed power. The optimization is carried out with respect to the source and relay precoding matrices, subject to QoS and power constraints. Such a challenging non-convex problem is tackled by means of fractional programming and and alternating maximization algorithms, for various CSI assumptions at the source and relay. In particular the scenarios of perfect CSI and those of statistical CSI for either the source-relay or the relay-destination channel are addressed. Moreover, sufficient conditions for beamforming optimality are derived, which is useful in simplifying the system design. Numerical results are provided to corroborate the validity of the theoretical findings.

  15. Optimum sample size allocation to minimize cost or maximize power for the two-sample trimmed mean test.

    PubMed

    Guo, Jiin-Huarng; Luh, Wei-Ming

    2009-05-01

    When planning a study, sample size determination is one of the most important tasks facing the researcher. The size will depend on the purpose of the study, the cost limitations, and the nature of the data. By specifying the standard deviation ratio and/or the sample size ratio, the present study considers the problem of heterogeneous variances and non-normality for Yuen's two-group test and develops sample size formulas to minimize the total cost or maximize the power of the test. For a given power, the sample size allocation ratio can be manipulated so that the proposed formulas can minimize the total cost, the total sample size, or the sum of total sample size and total cost. On the other hand, for a given total cost, the optimum sample size allocation ratio can maximize the statistical power of the test. After the sample size is determined, the present simulation applies Yuen's test to the sample generated, and then the procedure is validated in terms of Type I errors and power. Simulation results show that the proposed formulas can control Type I errors and achieve the desired power under the various conditions specified. Finally, the implications for determining sample sizes in experimental studies and future research are discussed.

  16. A maximally selected test of symmetry about zero.

    PubMed

    Laska, Eugene; Meisner, Morris; Wanderling, Joseph

    2012-11-20

    The problem of testing symmetry about zero has a long and rich history in the statistical literature. We introduce a new test that sequentially discards observations whose absolute value is below increasing thresholds defined by the data. McNemar's statistic is obtained at each threshold and the largest is used as the test statistic. We obtain the exact distribution of this maximally selected McNemar and provide tables of critical values and a program for computing p-values. Power is compared with the t-test, the Wilcoxon Signed Rank Test and the Sign Test. The new test, MM, is slightly less powerful than the t-test and Wilcoxon Signed Rank Test for symmetric normal distributions with nonzero medians and substantially more powerful than all three tests for asymmetric mixtures of normal random variables with or without zero medians. The motivation for this test derives from the need to appraise the safety profile of new medications. If pre and post safety measures are obtained, then under the null hypothesis, the variables are exchangeable and the distribution of their difference is symmetric about a zero median. Large pre-post differences are the major concern of a safety assessment. The discarded small observations are not particularly relevant to safety and can reduce power to detect important asymmetry. The new test was utilized on data from an on-road driving study performed to determine if a hypnotic, a drug used to promote sleep, has next day residual effects. Copyright © 2012 John Wiley & Sons, Ltd.

  17. efficient association study design via power-optimized tag SNP selection

    PubMed Central

    HAN, BUHM; KANG, HYUN MIN; SEO, MYEONG SEONG; ZAITLEN, NOAH; ESKIN, ELEAZAR

    2008-01-01

    Discovering statistical correlation between causal genetic variation and clinical traits through association studies is an important method for identifying the genetic basis of human diseases. Since fully resequencing a cohort is prohibitively costly, genetic association studies take advantage of local correlation structure (or linkage disequilibrium) between single nucleotide polymorphisms (SNPs) by selecting a subset of SNPs to be genotyped (tag SNPs). While many current association studies are performed using commercially available high-throughput genotyping products that define a set of tag SNPs, choosing tag SNPs remains an important problem for both custom follow-up studies as well as designing the high-throughput genotyping products themselves. The most widely used tag SNP selection method optimizes over the correlation between SNPs (r2). However, tag SNPs chosen based on an r2 criterion do not necessarily maximize the statistical power of an association study. We propose a study design framework that chooses SNPs to maximize power and efficiently measures the power through empirical simulation. Empirical results based on the HapMap data show that our method gains considerable power over a widely used r2-based method, or equivalently reduces the number of tag SNPs required to attain the desired power of a study. Our power-optimized 100k whole genome tag set provides equivalent power to the Affymetrix 500k chip for the CEU population. For the design of custom follow-up studies, our method provides up to twice the power increase using the same number of tag SNPs as r2-based methods. Our method is publicly available via web server at http://design.cs.ucla.edu. PMID:18702637

  18. Short-term Periodization Models: Effects on Strength and Speed-strength Performance.

    PubMed

    Hartmann, Hagen; Wirth, Klaus; Keiner, Michael; Mickel, Christoph; Sander, Andre; Szilvas, Elena

    2015-10-01

    Dividing training objectives into consecutive phases to gain morphological adaptations (hypertrophy phase) and neural adaptations (strength and power phases) is called strength-power periodization (SPP). These phases differ in program variables (volume, intensity, and exercise choice or type) and use stepwise intensity progression and concomitant decreasing volume, converging to peak intensity (peaking phase). Undulating periodization strategies rotate these program variables in a bi-weekly, weekly, or daily fashion. The following review addresses the effects of different short-term periodization models on strength and speed-strength both with subjects of different performance levels and with competitive athletes from different sports who use a particular periodization model during off-season, pre-season, and in-season conditioning. In most periodization studies, it is obvious that the strength endurance sessions are characterized by repetition zones (12-15 repetitions) that induce muscle hypertrophy in persons with a low performance level. Strictly speaking, when examining subjects with a low training level, many periodization studies include mainly hypertrophy sessions interspersed with heavy strength/power sessions. Studies have demonstrated equal or statistically significant higher gains in maximal strength for daily undulating periodization compared with SPP in subjects with a low to moderate performance level. The relatively short intervention period and the lack of concomitant sports conditioning call into question the practical value of these findings for competitive athletes. Possibly owing to differences in mesocycle length, conditioning programs, and program variables, competitive athletes either maintained or improved strength and/or speed-strength performance by integrating daily undulating periodization and SPP during off-season, pre-season and in-season conditioning. In high-performance sports, high-repetition strength training (>15) should be avoided because it does not provide an adequate training stimulus for gains in muscle cross-sectional area and strength performance. High-volume circuit strength training performed over 2 years negatively affected the development of the power output and maximal strength of the upper extremities in professional rugby players. Indeed, meta-analyses and results with weightlifters, American Football players, and throwers confirm the necessity of the habitual use of ≥80% 1 RM: (1) to improve maximal strength during the off-season and in-season in American Football, (2) to reach peak performance in maximal strength and vertical jump power during tapering in track-and-field, and (3) to produce hypertrophy and strength improvements in advanced athletes. The integration and extent of hypertrophy strength training in in-season conditioning depend on the duration of the contest period, the frequency of the contests, and the proportion of the conditioning program. Based on the literature, 72 h between hypertrophy strength training and strength-power training should be provided to allow for adequate regeneration times and therefore maximal stimulus intensities in training. This conclusion is only valid if the muscle is not trained otherwise during this regeneration phase. Thus, rotating hypertrophy and strength-power sessions in a microcycle during the season is a viable option. Comparative studies in competitive athletes who integrated strength training during pre-season conditioning confirm a tendency for gains in explosive strength and statistically significant improvements in medicine ball throw through SPP but not through daily undulating periodization. These findings indicate that to maximize the speed-strength in the short term (peaking), elite athletes should perform strength-power training twice per week. It is possible to perform a single strength-power session with the method of maximum explosive strength actions moving high-weight loads (90% 1 repetition maximum [RM]) at least 1-2 days before competition because of the shorter regeneration times and potentiation effects. Compared with ballistic strength training (30% 1 RM), this method has been shown to provide statistically superior gains in maximal strength, peak power, impulse size, and explosive strength during tapering in track-and-field throwers. The speed-strength performance in drop jumps of strength-trained subjects showed potentiation effects 48-148 h after a single strength-power training session. Regarding neuromuscular performance, plyometric exercises can even be performed after strength-power training on the same day if a minimum rest period of 3 h is provided.

  19. Multiplex sequencing of plant chloroplast genomes using Solexa sequencing-by-synthesis technology

    Treesearch

    Richard Cronn; Aaron Liston; Matthew Parks; David S. Gernandt; Rongkun Shen; Todd Mockler

    2008-01-01

    Organellar DNA sequences are widely used in evolutionary and population genetic studies; however, the conservative nature of chloroplast gene and genome evolution often limits phylogenetic resolution and statistical power. To gain maximal access to the historical record contained within chloroplast genomes, we have adapted multiplex sequencing-by-synthesis (MSBS) to...

  20. Integrated Analysis of Pharmacologic, Clinical, and SNP Microarray Data using Projection onto the Most Interesting Statistical Evidence with Adaptive Permutation Testing

    PubMed Central

    Pounds, Stan; Cao, Xueyuan; Cheng, Cheng; Yang, Jun; Campana, Dario; Evans, William E.; Pui, Ching-Hon; Relling, Mary V.

    2010-01-01

    Powerful methods for integrated analysis of multiple biological data sets are needed to maximize interpretation capacity and acquire meaningful knowledge. We recently developed Projection Onto the Most Interesting Statistical Evidence (PROMISE). PROMISE is a statistical procedure that incorporates prior knowledge about the biological relationships among endpoint variables into an integrated analysis of microarray gene expression data with multiple biological and clinical endpoints. Here, PROMISE is adapted to the integrated analysis of pharmacologic, clinical, and genome-wide genotype data that incorporating knowledge about the biological relationships among pharmacologic and clinical response data. An efficient permutation-testing algorithm is introduced so that statistical calculations are computationally feasible in this higher-dimension setting. The new method is applied to a pediatric leukemia data set. The results clearly indicate that PROMISE is a powerful statistical tool for identifying genomic features that exhibit a biologically meaningful pattern of association with multiple endpoint variables. PMID:21516175

  1. Age related neuromuscular changes in sEMG of m. Tibialis Anterior using higher order statistics (Gaussianity & linearity test).

    PubMed

    Siddiqi, Ariba; Arjunan, Sridhar P; Kumar, Dinesh K

    2016-08-01

    Age-associated changes in the surface electromyogram (sEMG) of Tibialis Anterior (TA) muscle can be attributable to neuromuscular alterations that precede strength loss. We have used our sEMG model of the Tibialis Anterior to interpret the age-related changes and compared with the experimental sEMG. Eighteen young (20-30 years) and 18 older (60-85 years) performed isometric dorsiflexion at 6 different percentage levels of maximum voluntary contractions (MVC), and their sEMG from the TA muscle was recorded. Six different age-related changes in the neuromuscular system were simulated using the sEMG model at the same MVCs as the experiment. The maximal power of the spectrum, Gaussianity and Linearity Test Statistics were computed from the simulated and experimental sEMG. A correlation analysis at α=0.05 was performed between the simulated and experimental age-related change in the sEMG features. The results show the loss in motor units was distinguished by the Gaussianity and Linearity test statistics; while the maximal power of the PSD distinguished between the muscular factors. The simulated condition of 40% loss of motor units with halved the number of fast fibers best correlated with the age-related change observed in the experimental sEMG higher order statistical features. The simulated aging condition found by this study corresponds with the moderate motor unit remodelling and negligible strength loss reported in literature for the cohorts aged 60-70 years.

  2. A simple method for measurement of maximal downstroke power on friction-loaded cycle ergometer.

    PubMed

    Morin, Jean-Benoît; Belli, Alain

    2004-01-01

    The aim of this study was to propose and validate a post-hoc correction method to obtain maximal power values taking into account inertia of the flywheel during sprints on friction-loaded cycle ergometers. This correction method was obtained from a basic postulate of linear deceleration-time evolution during the initial phase (until maximal power) of a sprint and included simple parameters as flywheel inertia, maximal velocity, time to reach maximal velocity and friction force. The validity of this model was tested by comparing measured and calculated maximal power values for 19 sprint bouts performed by five subjects against 0.6-1 N kg(-1) friction loads. Non-significant differences between measured and calculated maximal power (1151+/-169 vs. 1148+/-170 W) and a mean error index of 1.31+/-1.20% (ranging from 0.09% to 4.20%) showed the validity of this method. Furthermore, the differences between measured maximal power and power neglecting inertia (20.4+/-7.6%, ranging from 9.5% to 33.2%) emphasized the usefulness of power correcting in studies about anaerobic power which do not include inertia, and also the interest of this simple post-hoc method.

  3. Relationship between traditional and ballistic squat exercise with vertical jumping and maximal sprinting.

    PubMed

    Requena, Bernardo; García, Inmaculada; Requena, Francisco; de Villarreal, Eduardo Sáez-Sáez; Cronin, John B

    2011-08-01

    The purpose of this study was to quantify the magnitude of the relationship between vertical jumping and maximal sprinting at different distances with performance in the traditional and ballistic concentric squat exercise in well-trained sprinters. Twenty-one men performed 2 types of barbell squats (ballistic and traditional) across different loads with the aim of determining the maximal peak and average power outputs and 1 repetition maximum (1RM) values. Moreover, vertical jumping (countermovement jump test [CMJ]) and maximal sprints over 10, 20, 30, 40, 60, and 80 m were also assessed. In respect to 1RM in traditional squat, (a) no significant correlation was found with CMJ performance; (b) positive strong relationships (p < 0.01) were obtained with all the power measures obtained during both ballistic and traditional squat exercises (r = 0.53-0.90); (c) negative significant correlations (r = -0.49 to -0.59, p < 0.05) were found with sprint times in all the sprint distances measured when squat strength was expressed as a relative value; however, in the absolute mode, no significant relationships were observed with 10- and 20-m sprint times. No significant relationship was found between 10-m sprint time and relative or absolute power outputs using either ballistic or traditional squat exercises. Sprint time at 20 m was only related to ballistic and traditional squat performance when power values were expressed in relative terms. Moderate significant correlations (r = -0.39 to -0.56, p < 0.05) were observed between sprint times at 30 and 40 m and the absolute/relative power measures attained in both ballistic and traditional squat exercises. Sprint times at 60 and 80 m were mainly related to ballistic squat power outputs. Although correlations can only give insights into associations and not into cause and effect, from this investigation, it can be seen that traditional squat strength has little in common with CMJ performance and that relative 1RM and power outputs for both squat exercises are statistically correlated to most sprint distances underlying the importance of strength and power to sprinting.

  4. UNIFORMLY MOST POWERFUL BAYESIAN TESTS

    PubMed Central

    Johnson, Valen E.

    2014-01-01

    Uniformly most powerful tests are statistical hypothesis tests that provide the greatest power against a fixed null hypothesis among all tests of a given size. In this article, the notion of uniformly most powerful tests is extended to the Bayesian setting by defining uniformly most powerful Bayesian tests to be tests that maximize the probability that the Bayes factor, in favor of the alternative hypothesis, exceeds a specified threshold. Like their classical counterpart, uniformly most powerful Bayesian tests are most easily defined in one-parameter exponential family models, although extensions outside of this class are possible. The connection between uniformly most powerful tests and uniformly most powerful Bayesian tests can be used to provide an approximate calibration between p-values and Bayes factors. Finally, issues regarding the strong dependence of resulting Bayes factors and p-values on sample size are discussed. PMID:24659829

  5. Physiological Responses during Cycling With Oval Chainrings (Q-Ring) and Circular Chainrings.

    PubMed

    Cordova, Alfredo; Latasa, Iban; Seco, Jesus; Villa, Gerardo; Rodriguez-Falces, Javier

    2014-05-01

    The aim of this study was to compare the physiological responses of cyclists using round (C-ring) or oval (Q-ring) chainrings during an incremental test until exhaustion. Following a randomized design, twelve male elite cyclists [age (mean ± SD): 21.1 ± 2.1 yr; VO2max: 78.1 ± 5.3 mL·kg(-1)min(-1)] performed two incremental maximal tests separated by 48 h (one with C-rings, the other with Q-rings). Starting at 100 W, the workload was increased by 25 W every 3 min until volitional exhaustion. Maximal heart rate, power output and oxygen consumption were compared. Blood lactate was monitored throughout the test. After the incremental test, 4 intermittent 20-s maximal sprints with a 60-s recovery period in between were performed. Maximal isometric voluntary contractions were performed at rest and immediately after each 20-s maximal sprint, and the force and EMG RMS amplitude were recorded from the vastus medialis and vastus lateralis muscles. For the incremental exercise test, no significant differences were found in the maximal power output (P=0.12), oxygen consumption (P=0.39), and heart rate (P=0.32) between Q-rings and C-rings. Throughout the incremental test, lactate levels were comparable when using both the C-rings and Q-rings (P=0.47). During the short sprints, power output was 2.5-6.5% greater for Q-rings than for C-rings (P=0.22). The decline in EMG RMS amplitude observed during the incremental tests was comparable for Q-rings and C-rings (0.42). These findings indicate that the oval chainring design, presented here as "Q-rings", did not significantly influence the physiological response to an incremental exercise test as compared to a conventional chainring. Key pointsDuring the incremental exercise test, no significant differences were found in power output, oxygen consumption or heart rate between oval "Q-rings" and conventional chainrings.Over the course of the incremental test, blood lactate levels were comparable for the oval "Q-rings" and conventional chainrings.During the short sprints performed after the incremental test, there were no statistical differences in power production between oval "Q-rings" and conventional chainrings.

  6. A standard for test reliability in group research.

    PubMed

    Ellis, Jules L

    2013-03-01

    Many authors adhere to the rule that test reliabilities should be at least .70 or .80 in group research. This article introduces a new standard according to which reliabilities can be evaluated. This standard is based on the costs or time of the experiment and of administering the test. For example, if test administration costs are 7 % of the total experimental costs, the efficient value of the reliability is .93. If the actual reliability of a test is equal to this efficient reliability, the test size maximizes the statistical power of the experiment, given the costs. As a standard in experimental research, it is proposed that the reliability of the dependent variable be close to the efficient reliability. Adhering to this standard will enhance the statistical power and reduce the costs of experiments.

  7. Maximizing Statistical Power When Verifying Probabilistic Forecasts of Hydrometeorological Events

    NASA Astrophysics Data System (ADS)

    DeChant, C. M.; Moradkhani, H.

    2014-12-01

    Hydrometeorological events (i.e. floods, droughts, precipitation) are increasingly being forecasted probabilistically, owing to the uncertainties in the underlying causes of the phenomenon. In these forecasts, the probability of the event, over some lead time, is estimated based on some model simulations or predictive indicators. By issuing probabilistic forecasts, agencies may communicate the uncertainty in the event occurring. Assuming that the assigned probability of the event is correct, which is referred to as a reliable forecast, the end user may perform some risk management based on the potential damages resulting from the event. Alternatively, an unreliable forecast may give false impressions of the actual risk, leading to improper decision making when protecting resources from extreme events. Due to this requisite for reliable forecasts to perform effective risk management, this study takes a renewed look at reliability assessment in event forecasts. Illustrative experiments will be presented, showing deficiencies in the commonly available approaches (Brier Score, Reliability Diagram). Overall, it is shown that the conventional reliability assessment techniques do not maximize the ability to distinguish between a reliable and unreliable forecast. In this regard, a theoretical formulation of the probabilistic event forecast verification framework will be presented. From this analysis, hypothesis testing with the Poisson-Binomial distribution is the most exact model available for the verification framework, and therefore maximizes one's ability to distinguish between a reliable and unreliable forecast. Application of this verification system was also examined within a real forecasting case study, highlighting the additional statistical power provided with the use of the Poisson-Binomial distribution.

  8. Using Statistical Mechanics and Entropy Principles to Interpret Variability in Power Law Models of the Streamflow Recession

    NASA Astrophysics Data System (ADS)

    Dralle, D.; Karst, N.; Thompson, S. E.

    2015-12-01

    Multiple competing theories suggest that power law behavior governs the observed first-order dynamics of streamflow recessions - the important process by which catchments dry-out via the stream network, altering the availability of surface water resources and in-stream habitat. Frequently modeled as: dq/dt = -aqb, recessions typically exhibit a high degree of variability, even within a single catchment, as revealed by significant shifts in the values of "a" and "b" across recession events. One potential source of this variability lies in underlying, hard-to-observe fluctuations in how catchment water storage is partitioned amongst distinct storage elements, each having different discharge behaviors. Testing this and competing hypotheses with widely available streamflow timeseries, however, has been hindered by a power law scaling artifact that obscures meaningful covariation between the recession parameters, "a" and "b". Here we briefly outline a technique that removes this artifact, revealing intriguing new patterns in the joint distribution of recession parameters. Using long-term flow data from catchments in Northern California, we explore temporal variations, and find that the "a" parameter varies strongly with catchment wetness. Then we explore how the "b" parameter changes with "a", and find that measures of its variation are maximized at intermediate "a" values. We propose an interpretation of this pattern based on statistical mechanics, meaning "b" can be viewed as an indicator of the catchment "microstate" - i.e. the partitioning of storage - and "a" as a measure of the catchment macrostate (i.e. the total storage). In statistical mechanics, entropy (i.e. microstate variance, that is the variance of "b") is maximized for intermediate values of extensive variables (i.e. wetness, "a"), as observed in the recession data. This interpretation of "a" and "b" was supported by model runs using a multiple-reservoir catchment toy model, and lends support to the hypothesis that power law streamflow recession dynamics, and their variations, have their origin in the multiple modalities of storage partitioning.

  9. MIMO radar waveform design with peak and sum power constraints

    NASA Astrophysics Data System (ADS)

    Arulraj, Merline; Jeyaraman, Thiruvengadam S.

    2013-12-01

    Optimal power allocation for multiple-input multiple-output radar waveform design subject to combined peak and sum power constraints using two different criteria is addressed in this paper. The first one is by maximizing the mutual information between the random target impulse response and the reflected waveforms, and the second one is by minimizing the mean square error in estimating the target impulse response. It is assumed that the radar transmitter has knowledge of the target's second-order statistics. Conventionally, the power is allocated to transmit antennas based on the sum power constraint at the transmitter. However, the wide power variations across the transmit antenna pose a severe constraint on the dynamic range and peak power of the power amplifier at each antenna. In practice, each antenna has the same absolute peak power limitation. So it is desirable to consider the peak power constraint on the transmit antennas. A generalized constraint that jointly meets both the peak power constraint and the average sum power constraint to bound the dynamic range of the power amplifier at each transmit antenna is proposed recently. The optimal power allocation using the concept of waterfilling, based on the sum power constraint, is the special case of p = 1. The optimal solution for maximizing the mutual information and minimizing the mean square error is obtained through the Karush-Kuhn-Tucker (KKT) approach, and the numerical solutions are found through a nested Newton-type algorithm. The simulation results show that the detection performance of the system with both sum and peak power constraints gives better detection performance than considering only the sum power constraint at low signal-to-noise ratio.

  10. Validity and reliability of the PowerTap mobile cycling powermeter when compared with the SRM Device.

    PubMed

    Bertucci, W; Duc, S; Villerius, V; Pernin, J N; Grappe, F

    2005-12-01

    The SRM power measuring crank system is nowadays a popular device for cycling power output (PO) measurements in the field and in laboratories. The PowerTap (CycleOps, Madison, USA) is a more recent and less well-known device that allows mobile PO measurements of cycling via the rear wheel hub. The aim of this study is to test the validity and reliability of the PowerTap by comparing it with the most accurate (i.e. the scientific model) of the SRM system. The validity of the PowerTap is tested during i) sub-maximal incremental intensities (ranging from 100 to 420 W) on a treadmill with different pedalling cadences (45 to 120 rpm) and cycling positions (standing and seated) on different grades, ii) a continuous sub-maximal intensity lasting 30 min, iii) a maximal intensity (8-s sprint), and iiii) real road cycling. The reliability is assessed by repeating ten times the sub-maximal incremental and continuous tests. The results show a good validity of the PowerTap during sub-maximal intensities between 100 and 450 W (mean PO difference -1.2 +/- 1.3 %) when it is compared to the scientific SRM model, but less validity for the maximal PO during sprint exercise, where the validity appears to depend on the gear ratio. The reliability of the PowerTap during the sub-maximal intensities is similar to the scientific SRM model (the coefficient of variation is respectively 0.9 to 2.9 % and 0.7 to 2.1 % for PowerTap and SRM). The PowerTap must be considered as a suitable device for PO measurements during sub-maximal real road cycling and in sub-maximal laboratory tests.

  11. Equitability, mutual information, and the maximal information coefficient.

    PubMed

    Kinney, Justin B; Atwal, Gurinder S

    2014-03-04

    How should one quantify the strength of association between two random variables without bias for relationships of a specific form? Despite its conceptual simplicity, this notion of statistical "equitability" has yet to receive a definitive mathematical formalization. Here we argue that equitability is properly formalized by a self-consistency condition closely related to Data Processing Inequality. Mutual information, a fundamental quantity in information theory, is shown to satisfy this equitability criterion. These findings are at odds with the recent work of Reshef et al. [Reshef DN, et al. (2011) Science 334(6062):1518-1524], which proposed an alternative definition of equitability and introduced a new statistic, the "maximal information coefficient" (MIC), said to satisfy equitability in contradistinction to mutual information. These conclusions, however, were supported only with limited simulation evidence, not with mathematical arguments. Upon revisiting these claims, we prove that the mathematical definition of equitability proposed by Reshef et al. cannot be satisfied by any (nontrivial) dependence measure. We also identify artifacts in the reported simulation evidence. When these artifacts are removed, estimates of mutual information are found to be more equitable than estimates of MIC. Mutual information is also observed to have consistently higher statistical power than MIC. We conclude that estimating mutual information provides a natural (and often practical) way to equitably quantify statistical associations in large datasets.

  12. A Methodological Approach to Quantifying Plyometric Intensity.

    PubMed

    Jarvis, Mark M; Graham-Smith, Phil; Comfort, Paul

    2016-09-01

    Jarvis, MM, Graham-Smith, P, and Comfort, P. A Methodological approach to quantifying plyometric intensity. J Strength Cond Res 30(9): 2522-2532, 2016-In contrast to other methods of training, the quantification of plyometric exercise intensity is poorly defined. The purpose of this study was to evaluate the suitability of a range of neuromuscular and mechanical variables to describe the intensity of plyometric exercises. Seven male recreationally active subjects performed a series of 7 plyometric exercises. Neuromuscular activity was measured using surface electromyography (SEMG) at vastus lateralis (VL) and biceps femoris (BF). Surface electromyography data were divided into concentric (CON) and eccentric (ECC) phases of movement. Mechanical output was measured by ground reaction forces and processed to provide peak impact ground reaction force (PF), peak eccentric power (PEP), and impulse (IMP). Statistical analysis was conducted to assess the reliability intraclass correlation coefficient and sensitivity smallest detectable difference of all variables. Mean values of SEMG demonstrate high reliability (r ≥ 0.82), excluding ECC VL during a 40-cm drop jump (r = 0.74). PF, PEP, and IMP demonstrated high reliability (r ≥ 0.85). Statistical power for force variables was excellent (power = 1.0), and good for SEMG (power ≥0.86) excluding CON BF (power = 0.57). There was no significant difference (p > 0.05) in CON SEMG between exercises. Eccentric phase SEMG only distinguished between exercises involving a landing and those that did not (percentage of maximal voluntary isometric contraction [%MVIC] = no landing -65 ± 5, landing -140 ± 8). Peak eccentric power, PF, and IMP all distinguished between exercises. In conclusion, CON neuromuscular activity does not appear to vary when intent is maximal, whereas ECC activity is dependent on the presence of a landing. Force characteristics provide a reliable and sensitive measure enabling precise description of intensity in plyometric exercises. The present findings provide coaches and scientists with an insightful and precise method of measuring intensity in plyometrics, which will allow for greater control of programming variables.

  13. Noncircular Chainrings Do Not Influence Maximum Cycling Power.

    PubMed

    Leong, Chee-Hoi; Elmer, Steven J; Martin, James C

    2017-12-01

    Noncircular chainrings could increase cycling power by prolonging the powerful leg extension/flexion phases, and curtailing the low-power transition phases. We compared maximal cycling power-pedaling rate relationships, and joint-specific kinematics and powers across 3 chainring eccentricities (CON = 1.0; LOW ecc  = 1.13; HIGH ecc  = 1.24). Part I: Thirteen cyclists performed maximal inertial-load cycling under 3 chainring conditions. Maximum cycling power and optimal pedaling rate were determined. Part II: Ten cyclists performed maximal isokinetic cycling (120 rpm) under the same 3 chainring conditions. Pedal and joint-specific powers were determined using pedal forces and limb kinematics. Neither maximal cycling power nor optimal pedaling rate differed across chainring conditions (all p > .05). Peak ankle angular velocity for HIGH ecc was less than CON (p < .05), while knee and hip angular velocities were unaffected. Self-selected ankle joint-center trajectory was more eccentric than HIGH ecc with an opposite orientation that increased velocity during extension/flexion and reduced velocity during transitions. Joint-specific powers did not differ across chainring conditions, with a small increase in power absorbed during ankle dorsiflexion with HIGH ecc . Multiple degrees of freedom in the leg, crank, and pedal system allowed cyclists to manipulate ankle angular velocity to maintain their preferred knee and hip actions, suggesting maximizing extension/flexion and minimizing transition phases may be counterproductive for maximal power.

  14. Distinguishing Positive Selection From Neutral Evolution: Boosting the Performance of Summary Statistics

    PubMed Central

    Lin, Kao; Li, Haipeng; Schlötterer, Christian; Futschik, Andreas

    2011-01-01

    Summary statistics are widely used in population genetics, but they suffer from the drawback that no simple sufficient summary statistic exists, which captures all information required to distinguish different evolutionary hypotheses. Here, we apply boosting, a recent statistical method that combines simple classification rules to maximize their joint predictive performance. We show that our implementation of boosting has a high power to detect selective sweeps. Demographic events, such as bottlenecks, do not result in a large excess of false positives. A comparison to other neutrality tests shows that our boosting implementation performs well compared to other neutrality tests. Furthermore, we evaluated the relative contribution of different summary statistics to the identification of selection and found that for recent sweeps integrated haplotype homozygosity is very informative whereas older sweeps are better detected by Tajima's π. Overall, Watterson's θ was found to contribute the most information for distinguishing between bottlenecks and selection. PMID:21041556

  15. Anaerobic and Aerobic Performance of Elite Female and Male Snowboarders

    PubMed Central

    Żebrowska, Aleksandra; Żyła, Dorota; Kania, Damian; Langfort, Józef

    2012-01-01

    The physiological adaptation to training is specific to the muscle activity, dominant energy system involved, muscle groups trained, as well as intensity and volume of training. Despite increasing popularity of snowboarding only little scientific data is available on the physiological characteristics of female and male competitive snowboarders. Therefore, the purpose of this study was to compare the aerobic capacity and maximal anaerobic power of elite Polish snowboarders with untrained subjects. Ten snowboarders and ten aged matched students of Physical Education performed two exercise tests. First, a 30-second Wingate test was conducted and next, a cycle ergometer exercise test with graded intensity. In the first test, peak anaerobic power, the total work, relative peak power and relative mean power were measured. During the second test, relative maximal oxygen uptake and lactate threshold were evaluated. There were no significant differences in absolute and relative maximal oxygen uptake between snowboarders and the control group. Mean maximal oxygen uptake and lactate threshold were significantly higher in men than in women. Significant differences were found between trained men and women regarding maximal power and relative maximal power. The elite snowboarders demonstrated a high level of anaerobic power. The level of relative peak power in trained women correlated negatively with maximal oxygen uptake. In conclusion, our results seem to indicate that the demanding competition program of elite snowboarders provides a significant training stimulus mainly for anaerobic power with minor changes in anaerobic performance. PMID:23487498

  16. Body-mass dependence of age-related deterioration in human muscular function.

    PubMed

    Meltzer, D E

    1996-04-01

    Maximal anaerobic power of human muscles declines with increasing chronological age and is correlated with body mass. This study investigated whether the rate of deterioration in human muscular function among trained weight lifters is also correlated with body mass. Cross-sectional analysis of performance data of over 1,100 Masters competitors in Olympic-style weight lifting was carried out; eight body-weight classes and six age groups were represented. Two-lift total data (sum of snatch and clean and jerk lifts) were analyzed. Mean deterioration rates in the performance of athletes of widely diverse body masses were compared over the following age ranges: 42-57, 42-62, and 42-67 yr. No statistically significant correlation (P < 0.05) was found between rate of performance decline and body mass. The relationship between body mass and the magnitude of age-related variation of deterioration rate was also studied; no significant correlation was found. Previous studies have demonstrated that performance in Olympic-style weight lifting is correlated with maximal anaerobic muscular power. This leads us to suggest that the age-related deterioration rate of anaerobic power in trained subjects may not be correlated with the body mass of the individual.

  17. Maximizing ecological and evolutionary insight in bisulfite sequencing data sets

    PubMed Central

    Lea, Amanda J.; Vilgalys, Tauras P.; Durst, Paul A.P.; Tung, Jenny

    2017-01-01

    Preface Genome-scale bisulfite sequencing approaches have opened the door to ecological and evolutionary studies of DNA methylation in many organisms. These approaches can be powerful. However, they introduce new methodological and statistical considerations, some of which are particularly relevant to non-model systems. Here, we highlight how these considerations influence a study’s power to link methylation variation with a predictor variable of interest. Relative to current practice, we argue that sample sizes will need to increase to provide robust insights. We also provide recommendations for overcoming common challenges and an R Shiny app to aid in study design. PMID:29046582

  18. Seven ways to increase power without increasing N.

    PubMed

    Hansen, W B; Collins, L M

    1994-01-01

    Many readers of this monograph may wonder why a chapter on statistical power was included. After all, by now the issue of statistical power is in many respects mundane. Everyone knows that statistical power is a central research consideration, and certainly most National Institute on Drug Abuse grantees or prospective grantees understand the importance of including a power analysis in research proposals. However, there is ample evidence that, in practice, prevention researchers are not paying sufficient attention to statistical power. If they were, the findings observed by Hansen (1992) in a recent review of the prevention literature would not have emerged. Hansen (1992) examined statistical power based on 46 cohorts followed longitudinally, using nonparametric assumptions given the subjects' age at posttest and the numbers of subjects. Results of this analysis indicated that, in order for a study to attain 80-percent power for detecting differences between treatment and control groups, the difference between groups at posttest would need to be at least 8 percent (in the best studies) and as much as 16 percent (in the weakest studies). In order for a study to attain 80-percent power for detecting group differences in pre-post change, 22 of the 46 cohorts would have needed relative pre-post reductions of greater than 100 percent. Thirty-three of the 46 cohorts had less than 50-percent power to detect a 50-percent relative reduction in substance use. These results are consistent with other review findings (e.g., Lipsey 1990) that have shown a similar lack of power in a broad range of research topics. Thus, it seems that, although researchers are aware of the importance of statistical power (particularly of the necessity for calculating it when proposing research), they somehow are failing to end up with adequate power in their completed studies. This chapter argues that the failure of many prevention studies to maintain adequate statistical power is due to an overemphasis on sample size (N) as the only, or even the best, way to increase statistical power. It is easy to see how this overemphasis has come about. Sample size is easy to manipulate, has the advantage of being related to power in a straight-forward way, and usually is under the direct control of the researcher, except for limitations imposed by finances or subject availability. Another option for increasing power is to increase the alpha used for hypothesis-testing but, as very few researchers seriously consider significance levels much larger than the traditional .05, this strategy seldom is used. Of course, sample size is important, and the authors of this chapter are not recommending that researchers cease choosing sample sizes carefully. Rather, they argue that researchers should not confine themselves to increasing N to enhance power. It is important to take additional measures to maintain and improve power over and above making sure the initial sample size is sufficient. The authors recommend two general strategies. One strategy involves attempting to maintain the effective initial sample size so that power is not lost needlessly. The other strategy is to take measures to maximize the third factor that determines statistical power: effect size.

  19. Effects of ethnicity on the relationship between vertical jump and maximal power on a cycle ergometer.

    PubMed

    Rouis, Majdi; Coudrat, Laure; Jaafar, Hamdi; Attiogbé, Elvis; Vandewalle, Henry; Driss, Tarak

    2016-06-01

    The aim of this study was to verify the impact of ethnicity on the maximal power-vertical jump relationship. Thirty-one healthy males, sixteen Caucasian (age: 26.3 ± 3.5 years; body height: 179.1 ± 5.5 cm; body mass: 78.1 ± 9.8 kg) and fifteen Afro-Caribbean (age: 24.4 ±2.6 years; body height: 178.9 ± 5.5 cm; body mass: 77.1 ± 10.3 kg) completed three sessions during which vertical jump height and maximal power of lower limbs were measured. The results showed that the values of vertical jump height and maximal power were higher for Afro-Caribbean participants (62.92 ± 6.7 cm and 14.70 ± 1.75 W∙kg-1) than for Caucasian ones (52.92 ± 4.4 cm and 12.75 ± 1.36 W∙kg-1). Moreover, very high reliability indices were obtained on vertical jump (e.g. 0.95 < ICC < 0.98) and maximal power performance (e.g. 0.75 < ICC < 0.97). However, multiple linear regression analysis showed that, for a given value of maximal power, the Afro-Caribbean participants jumped 8 cm higher than the Caucasians. Together, these results confirmed that ethnicity impacted the maximal power-vertical jump relationship over three sessions. In the current context of cultural diversity, the use of vertical jump performance as a predictor of muscular power should be considered with caution when dealing with populations of different ethnic origins.

  20. Optimal choice of word length when comparing two Markov sequences using a χ 2-statistic.

    PubMed

    Bai, Xin; Tang, Kujin; Ren, Jie; Waterman, Michael; Sun, Fengzhu

    2017-10-03

    Alignment-free sequence comparison using counts of word patterns (grams, k-tuples) has become an active research topic due to the large amount of sequence data from the new sequencing technologies. Genome sequences are frequently modelled by Markov chains and the likelihood ratio test or the corresponding approximate χ 2 -statistic has been suggested to compare two sequences. However, it is not known how to best choose the word length k in such studies. We develop an optimal strategy to choose k by maximizing the statistical power of detecting differences between two sequences. Let the orders of the Markov chains for the two sequences be r 1 and r 2 , respectively. We show through both simulations and theoretical studies that the optimal k= max(r 1 ,r 2 )+1 for both long sequences and next generation sequencing (NGS) read data. The orders of the Markov chains may be unknown and several methods have been developed to estimate the orders of Markov chains based on both long sequences and NGS reads. We study the power loss of the statistics when the estimated orders are used. It is shown that the power loss is minimal for some of the estimators of the orders of Markov chains. Our studies provide guidelines on choosing the optimal word length for the comparison of Markov sequences.

  1. Power Converters Maximize Outputs Of Solar Cell Strings

    NASA Technical Reports Server (NTRS)

    Frederick, Martin E.; Jermakian, Joel B.

    1993-01-01

    Microprocessor-controlled dc-to-dc power converters devised to maximize power transferred from solar photovoltaic strings to storage batteries and other electrical loads. Converters help in utilizing large solar photovoltaic arrays most effectively with respect to cost, size, and weight. Main points of invention are: single controller used to control and optimize any number of "dumb" tracker units and strings independently; power maximized out of converters; and controller in system is microprocessor.

  2. Carnot cycle at finite power: attainability of maximal efficiency.

    PubMed

    Allahverdyan, Armen E; Hovhannisyan, Karen V; Melkikh, Alexey V; Gevorkian, Sasun G

    2013-08-02

    We want to understand whether and to what extent the maximal (Carnot) efficiency for heat engines can be reached at a finite power. To this end we generalize the Carnot cycle so that it is not restricted to slow processes. We show that for realistic (i.e., not purposefully designed) engine-bath interactions, the work-optimal engine performing the generalized cycle close to the maximal efficiency has a long cycle time and hence vanishing power. This aspect is shown to relate to the theory of computational complexity. A physical manifestation of the same effect is Levinthal's paradox in the protein folding problem. The resolution of this paradox for realistic proteins allows to construct engines that can extract at a finite power 40% of the maximally possible work reaching 90% of the maximal efficiency. For purposefully designed engine-bath interactions, the Carnot efficiency is achievable at a large power.

  3. A randomized evaluation of a computer-based physician's workstation: design considerations and baseline results.

    PubMed Central

    Rotman, B. L.; Sullivan, A. N.; McDonald, T.; DeSmedt, P.; Goodnature, D.; Higgins, M.; Suermondt, H. J.; Young, C. Y.; Owens, D. K.

    1995-01-01

    We are performing a randomized, controlled trial of a Physician's Workstation (PWS), an ambulatory care information system, developed for use in the General Medical Clinic (GMC) of the Palo Alto VA. Goals for the project include selecting appropriate outcome variables and developing a statistically powerful experimental design with a limited number of subjects. As PWS provides real-time drug-ordering advice, we retrospectively examined drug costs and drug-drug interactions in order to select outcome variables sensitive to our short-term intervention as well as to estimate the statistical efficiency of alternative design possibilities. Drug cost data revealed the mean daily cost per physician per patient was 99.3 cents +/- 13.4 cents, with a range from 0.77 cent to 1.37 cents. The rate of major interactions per prescription for each physician was 2.9% +/- 1%, with a range from 1.5% to 4.8%. Based on these baseline analyses, we selected a two-period parallel design for the evaluation, which maximized statistical power while minimizing sources of bias. PMID:8563376

  4. GAPIT: genome association and prediction integrated tool.

    PubMed

    Lipka, Alexander E; Tian, Feng; Wang, Qishan; Peiffer, Jason; Li, Meng; Bradbury, Peter J; Gore, Michael A; Buckler, Edward S; Zhang, Zhiwu

    2012-09-15

    Software programs that conduct genome-wide association studies and genomic prediction and selection need to use methodologies that maximize statistical power, provide high prediction accuracy and run in a computationally efficient manner. We developed an R package called Genome Association and Prediction Integrated Tool (GAPIT) that implements advanced statistical methods including the compressed mixed linear model (CMLM) and CMLM-based genomic prediction and selection. The GAPIT package can handle large datasets in excess of 10 000 individuals and 1 million single-nucleotide polymorphisms with minimal computational time, while providing user-friendly access and concise tables and graphs to interpret results. http://www.maizegenetics.net/GAPIT. zhiwu.zhang@cornell.edu Supplementary data are available at Bioinformatics online.

  5. A new numerical method for calculating extrema of received power for polarimetric SAR

    USGS Publications Warehouse

    Zhang, Y.; Zhang, Jiahua; Lu, Z.; Gong, W.

    2009-01-01

    A numerical method called cross-step iteration is proposed to calculate the maximal/minimal received power for polarized imagery based on a target's Kennaugh matrix. This method is much more efficient than the systematic method, which searches for the extrema of received power by varying the polarization ellipse angles of receiving and transmitting polarizations. It is also more advantageous than the Schuler method, which has been adopted by the PolSARPro package, because the cross-step iteration method requires less computation time and can derive both the maximal and minimal received powers, whereas the Schuler method is designed to work out only the maximal received power. The analytical model of received-power optimization indicates that the first eigenvalue of the Kennaugh matrix is the supremum of the maximal received power. The difference between these two parameters reflects the depolarization effect of the target's backscattering, which might be useful for target discrimination. ?? 2009 IEEE.

  6. On base station cooperation using statistical CSI in jointly correlated MIMO downlink channels

    NASA Astrophysics Data System (ADS)

    Zhang, Jun; Jiang, Bin; Jin, Shi; Gao, Xiqi; Wong, Kai-Kit

    2012-12-01

    This article studies the transmission of a single cell-edge user's signal using statistical channel state information at cooperative base stations (BSs) with a general jointly correlated multiple-input multiple-output (MIMO) channel model. We first present an optimal scheme to maximize the ergodic sum capacity with per-BS power constraints, revealing that the transmitted signals of all BSs are mutually independent and the optimum transmit directions for each BS align with the eigenvectors of the BS's own transmit correlation matrix of the channel. Then, we employ matrix permanents to derive a closed-form tight upper bound for the ergodic sum capacity. Based on these results, we develop a low-complexity power allocation solution using convex optimization techniques and a simple iterative water-filling algorithm (IWFA) for power allocation. Finally, we derive a necessary and sufficient condition for which a beamforming approach achieves capacity for all BSs. Simulation results demonstrate that the upper bound of ergodic sum capacity is tight and the proposed cooperative transmission scheme increases the downlink system sum capacity considerably.

  7. Older men are more fatigable than young when matched for maximal power and knee extension angular velocity is unconstrained.

    PubMed

    Dalton, Brian H; Power, Geoffrey A; Paturel, Justin R; Rice, Charles L

    2015-06-01

    The underlying factors related to the divergent findings of age-related fatigue for dynamic tasks are not well understood. The purpose here was to investigate age-related fatigability and recovery between a repeated constrained (isokinetic) and an unconstrained velocity (isotonic) task, in which participants performed fatiguing contractions at the velocity (isokinetic) or resistance (isotonic) corresponding with maximal power. To compare between tasks, isotonic torque-power relationships were constructed prior to and following both fatiguing tasks and during short-term recovery. Contractile properties were recorded from 9 old (~75 years) and 11 young (~25 years) men during three testing sessions. In the first session, maximal power was assessed, and sessions 2 and 3 involved an isokinetic or an isotonic concentric fatigue task performed until maximal power was reduced by 40 %. Compared with young, the older men performed the same number of contractions to task failure for the isokinetic task (~45 contractions), but 20 % fewer for the isotonic task (p < 0.05). Regardless of age and task, maximal voluntary isometric contraction strength, angular velocity, and power were reduced by ~30, ~13, and ~25 %, respectively, immediately following task failure, and only isometric torque was not recovered fully by 10 min. In conclusion, older men are more fatigable than the young when performing a repetitive maximal dynamic task at a relative resistance (isotonic) but not an absolute velocity (isokinetic), corresponding to maximal power.

  8. Effects of a Non-Circular Chainring on Sprint Performance During a Cycle Ergometer Test

    PubMed Central

    Hintzy, Frédérique; Grappe, Frédéric; Belli, Alain

    2016-01-01

    Non-circular chainrings have been reported to alter the crank angular velocity profile over a pedal revolution so that more time is spent in the effective power phase. The purpose of this study was to determine whether sprint cycling performance could be improved using a non-circular chainring (Osymetric: ellipticity 1.25 and crank lever mounted nearly perpendicular to the major axis), in comparison with a circular chainring. Twenty sprint cyclists performed an 8 s sprint on a cycle ergometer against a 0.5 N/kg-1 friction force in four crossing conditions (non-circular or circular chainring with or without clipless pedal). Instantaneous force, velocity and power were continuously measured during each sprint. Three main characteristic pedal downstrokes were selected: maximal force (in the beginning of the sprint), maximal power (towards the middle), and maximal velocity (at the end of the sprint). Both average and instantaneous force, velocity and power were calculated during the three selected pedal downstrokes. The important finding of this study was that the maximal power output was significantly higher (+ 4.3%, p < 0.05) when using the non-circular chainring independent from the shoe-pedal linkage condition. This improvement is mainly explained by a significantly higher instantaneous external force that occurs during the downstroke. Non-circular chainring can have potential benefits on sprint cycling performance. Key points The Osymetric non-circular chainring significantly maximized crank power by 4.3% during sprint cycling, in comparison with a circular chainring. This maximal power output improvement was due to significant higher force developed when the crank was in the effective power phase. This maximal power output improvement was independent from the shoe-pedal linkage condition. Present benefits provided by the non-circular chainring on pedalling kinetics occurred only at high cadences. PMID:27274658

  9. Interim analyses in 2 x 2 crossover trials.

    PubMed

    Cook, R J

    1995-09-01

    A method is presented for performing interim analyses in long term 2 x 2 crossover trials with serial patient entry. The analyses are based on a linear statistic that combines data from individuals observed for one treatment period with data from individuals observed for both periods. The coefficients in this linear combination can be chosen quite arbitrarily, but we focus on variance-based weights to maximize power for tests regarding direct treatment effects. The type I error rate of this procedure is controlled by utilizing the joint distribution of the linear statistics over analysis stages. Methods for performing power and sample size calculations are indicated. A two-stage sequential design involving simultaneous patient entry and a single between-period interim analysis is considered in detail. The power and average number of measurements required for this design are compared to those of the usual crossover trial. The results indicate that, while there is minimal loss in power relative to the usual crossover design in the absence of differential carry-over effects, the proposed design can have substantially greater power when differential carry-over effects are present. The two-stage crossover design can also lead to more economical studies in terms of the expected number of measurements required, due to the potential for early stopping. Attention is directed toward normally distributed responses.

  10. Matching relations for optimal entanglement concentration and purification

    PubMed Central

    Kong, Fan-Zhen; Xia, Hui-Zhi; Yang, Ming; Yang, Qing; Cao, Zhuo-Liang

    2016-01-01

    The bilateral controlled NOT (CNOT) operation plays a key role in standard entanglement purification process, but the CNOT operation may not be the optimal joint operation in the sense that the output entanglement is maximized. In this paper, the CNOT operations in both the Schmidt-projection based entanglement concentration and the entanglement purification schemes are replaced with a general joint unitary operation, and the optimal matching relations between the entangling power of the joint unitary operation and the non-maximal entangled channel are found for optimizing the entanglement in- crement or the output entanglement. The result is somewhat counter-intuitive for entanglement concentration. The output entanglement is maximized when the entangling power of the joint unitary operation and the quantum channel satisfy certain relation. There exist a variety of joint operations with non-maximal entangling power that can induce a maximal output entanglement, which will greatly broaden the set of the potential joint operations in entanglement concentration. In addition, the entanglement increment in purification process is maximized only by the joint unitary operations (including CNOT) with maximal entangling power. PMID:27189800

  11. Information-theoretic approach to interactive learning

    NASA Astrophysics Data System (ADS)

    Still, S.

    2009-01-01

    The principles of statistical mechanics and information theory play an important role in learning and have inspired both theory and the design of numerous machine learning algorithms. The new aspect in this paper is a focus on integrating feedback from the learner. A quantitative approach to interactive learning and adaptive behavior is proposed, integrating model- and decision-making into one theoretical framework. This paper follows simple principles by requiring that the observer's world model and action policy should result in maximal predictive power at minimal complexity. Classes of optimal action policies and of optimal models are derived from an objective function that reflects this trade-off between prediction and complexity. The resulting optimal models then summarize, at different levels of abstraction, the process's causal organization in the presence of the learner's actions. A fundamental consequence of the proposed principle is that the learner's optimal action policies balance exploration and control as an emerging property. Interestingly, the explorative component is present in the absence of policy randomness, i.e. in the optimal deterministic behavior. This is a direct result of requiring maximal predictive power in the presence of feedback.

  12. Deconstructing the power resistance relationship for squats: A joint-level analysis.

    PubMed

    Farris, D J; Lichtwark, G A; Brown, N A T; Cresswell, A G

    2016-07-01

    Generating high leg power outputs is important for executing rapid movements. Squats are commonly used to increase leg strength and power. Therefore, it is useful to understand factors affecting power output in squatting. We aimed to deconstruct the mechanisms behind why power is maximized at certain resistances in squatting. Ten male rowers (age = 20 ± 2.2 years; height = 1.82 ± 0.03 m; mass = 86 ± 11 kg) performed maximal power squats with resistances ranging from body weight to 80% of their one repetition maximum (1RM). Three-dimensional kinematics was combined with ground reaction force (GRF) data in an inverse dynamics analysis to calculate leg joint moments and powers. System center of mass (COM) velocity and power were computed from GRF data. COM power was maximized across a range of resistances from 40% to 60% 1RM. This range was identified because a trade-off in hip and knee joint powers existed across this range, with maximal knee joint power occurring at 40% 1RM and maximal hip joint power at 60% 1RM. A non-linear system force-velocity relationship was observed that dictated large reductions in COM power below 20% 1RM and above 60% 1RM. These reductions were due to constraints on the control of the movement. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Estimating the total energy demand for supra-maximal exercise using the VO2-power regression from an incremental exercise test.

    PubMed

    Aisbett, B; Le Rossignol, P

    2003-09-01

    The VO2-power regression and estimated total energy demand for a 6-minute supra-maximal exercise test was predicted from a continuous incremental exercise test. Sub-maximal VO2-power co-ordinates were established from the last 40 seconds (s) of 150-second exercise stages. The precision of the estimated total energy demand was determined using the 95% confidence interval (95% CI) of the estimated total energy demand. The linearity of the individual VO2-power regression equations was determined using Pearson's correlation coefficient. The mean 95% CI of the estimated total energy demand was 5.9 +/- 2.5 mL O2 Eq x kg(-1) x min(-1), and the mean correlation coefficient was 0.9942 +/- 0.0042. The current study contends that the sub-maximal VO2-power co-ordinates from a continuous incremental exercise test can be used to estimate supra-maximal energy demand without compromising the precision of the accumulated oxygen deficit (AOD) method.

  14. Experimental design and statistical methods for improved hit detection in high-throughput screening.

    PubMed

    Malo, Nathalie; Hanley, James A; Carlile, Graeme; Liu, Jing; Pelletier, Jerry; Thomas, David; Nadon, Robert

    2010-09-01

    Identification of active compounds in high-throughput screening (HTS) contexts can be substantially improved by applying classical experimental design and statistical inference principles to all phases of HTS studies. The authors present both experimental and simulated data to illustrate how true-positive rates can be maximized without increasing false-positive rates by the following analytical process. First, the use of robust data preprocessing methods reduces unwanted variation by removing row, column, and plate biases. Second, replicate measurements allow estimation of the magnitude of the remaining random error and the use of formal statistical models to benchmark putative hits relative to what is expected by chance. Receiver Operating Characteristic (ROC) analyses revealed superior power for data preprocessed by a trimmed-mean polish method combined with the RVM t-test, particularly for small- to moderate-sized biological hits.

  15. Somatotype-variables related to muscle torque and power output in female volleyball players.

    PubMed

    Buśko, Krzysztof; Lewandowska, Joanna; Lipińska, Monika; Michalski, Radosław; Pastuszak, Anna

    2013-01-01

    The purpose of this study was to investigate the relationship between somatotype, muscle torque, maximal power output and height of rise of the body mass centre measured in akimbo counter movement jump (ACMJ), counter movement jump (CMJ) and spike jump (SPJ), and power output measured in maximal cycle ergometer exercise bouts in female volleyball players. Fourteen players participated in the study. Somatotype was determined using the Heath-Carter method. Maximal muscle torque was measured under static conditions. Power output was measured in 5 maximal cycle ergometer exercise bouts, 10 s each, at increasing external loads equal to 2.5, 5.0, 7.5, 10.0 and 12.5% of body weight (BW). All jump trials (ACMJ, SPJ and CMJ) were performed on a force plate. The mean somatotype of volleyball players was: 4.9-3.5-2.5. The value of the sum of muscle torque of the left upper extremities was significantly correlated only with mesomorphic component. Mesomorphic and ectomorphic components correlated significantly with values of maximal power measured during ACMJ and CMJ. Power output measured in maximal cycle ergometer exercise bouts at increasing external loads equal to 2.5, 5.0 and 7.5% of BW was significantly correlated with endomorphy, mesomorphy and ectomorphy.

  16. Changes in aerobic power of men, ages 25-70 yr

    NASA Technical Reports Server (NTRS)

    Jackson, A. S.; Beard, E. F.; Wier, L. T.; Ross, R. M.; Stuteville, J. E.; Blair, S. N.

    1995-01-01

    This study quantified and compared the cross-sectional and longitudinal influence of age, self-report physical activity (SR-PA), and body composition (%fat) on the decline of maximal aerobic power (VO2peak). The cross-sectional sample consisted of 1,499 healthy men ages 25-70 yr. The 156 men of the longitudinal sample were from the same population and examined twice, the mean time between tests was 4.1 (+/- 1.2) yr. Peak oxygen uptake was determined by indirect calorimetry during a maximal treadmill exercise test. The zero-order correlations between VO2peak and %fat (r = -0.62) and SR-PA (r = 0.58) were significantly (P < 0.05) higher that the age correlation (r = -0.45). Linear regression defined the cross-sectional age-related decline in VO2peak at 0.46 ml.kg-1.min-1.yr-1. Multiple regression analysis (R = 0.79) showed that nearly 50% of this cross-sectional decline was due to %fat and SR-PA, adding these lifestyle variables to the multiple regression model reduced the age regression weight to -0.26 ml.kg-1.min-1.yr-1. Statistically controlling for time differences between tests, general linear models analysis showed that longitudinal changes in aerobic power were due to independent changes in %fat and SR-PA, confirming the cross-sectional results.

  17. Laboratory- and Field-Based Assessment of Maximal Aerobic Power of Elite Stand-Up Paddle-Board Athletes.

    PubMed

    Schram, Ben; Hing, Wayne; Climstein, Mike

    2016-01-01

    Stand-up paddle boarding (SUP) is a rapidly growing sport and recreational activity for which only anecdotal evidence exists on its proposed health, fitness, and injury-rehabilitation benefits. 10 internationally and nationally ranked elite SUP athletes. Participants were assessed for their maximal aerobic power on an ergometer in a laboratory and compared with other water-based athletes. Field-based assessments were subsequently performed using a portable gas-analysis system, and a correlation between the 2 measures was performed. Maximal aerobic power (relative) was significantly higher (P = .037) when measured in the field with a portable gas-analysis system (45.48 ± 6.96 mL · kg(-1) · min(-1)) than with laboratory-based metabolic-cart measurements (43.20 ± 6.67 mL · kg(-1) · min(-1)). There was a strong, positive correlation (r = .907) between laboratory and field maximal aerobic power results. Significantly higher (P = .000) measures of SUP paddling speed were found in the field than with the laboratory ergometer (+42.39%). There were no significant differences in maximal heart rate between the laboratory and field settings (P = .576). The results demonstrate the maximal aerobic power representative of internationally and nationally ranked SUP athletes and show that SUP athletes can be assessed for maximal aerobic power in the laboratory with high correlation to field-based measures. The field-based portable gas-analysis unit has a tendency to consistently measure higher oxygen consumption. Elite SUP athletes display aerobic power outputs similar to those of other upper-limb-dominant elite water-based athletes (surfing, dragon-boat racing, and canoeing).

  18. Power maximization of a point absorber wave energy converter using improved model predictive control

    NASA Astrophysics Data System (ADS)

    Milani, Farideh; Moghaddam, Reihaneh Kardehi

    2017-08-01

    This paper considers controlling and maximizing the absorbed power of wave energy converters for irregular waves. With respect to physical constraints of the system, a model predictive control is applied. Irregular waves' behavior is predicted by Kalman filter method. Owing to the great influence of controller parameters on the absorbed power, these parameters are optimized by imperialist competitive algorithm. The results illustrate the method's efficiency in maximizing the extracted power in the presence of unknown excitation force which should be predicted by Kalman filter.

  19. “Forward Genetics” as a Method to Maximize Power and Cost-Efficiency in Studies of Human Complex Traits

    PubMed Central

    Derks, E. M.; Dolan, C. V.; Kahn, R. S.; Ophoff, R. A.

    2010-01-01

    There is increasing interest in methods to disentangle the relationship between genotype and (endo)phenotypes in human complex traits. We present a population-based method of increasing the power and cost-efficiency of studies by selecting random individuals with a particular genotype and then assessing the accompanying quantitative phenotypes. Using statistical derivations, power- and cost graphs we show that such a “forward genetics” approach can lead to a marked reduction in sample size and costs. This approach is particularly apt for implementing in epidemiological studies for which DNA is already available but the phenotyping costs are high. Electronic supplementary material The online version of this article (doi:10.1007/s10519-010-9348-y) contains supplementary material, which is available to authorized users. PMID:20232132

  20. Dual-loop self-optimizing robust control of wind power generation with Doubly-Fed Induction Generator.

    PubMed

    Chen, Quan; Li, Yaoyu; Seem, John E

    2015-09-01

    This paper presents a self-optimizing robust control scheme that can maximize the power generation for a variable speed wind turbine with Doubly-Fed Induction Generator (DFIG) operated in Region 2. A dual-loop control structure is proposed to synergize the conversion from aerodynamic power to rotor power and the conversion from rotor power to the electrical power. The outer loop is an Extremum Seeking Control (ESC) based generator torque regulation via the electric power feedback. The ESC can search for the optimal generator torque constant to maximize the rotor power without wind measurement or accurate knowledge of power map. The inner loop is a vector-control based scheme that can both regulate the generator torque requested by the ESC and also maximize the conversion from the rotor power to grid power. An ℋ(∞) controller is synthesized for maximizing, with performance specifications defined based upon the spectrum of the rotor power obtained by the ESC. Also, the controller is designed to be robust against the variations of some generator parameters. The proposed control strategy is validated via simulation study based on the synergy of several software packages including the TurbSim and FAST developed by NREL, Simulink and SimPowerSystems. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  1. The reliability of isoinertial force-velocity-power profiling and maximal strength assessment in youth.

    PubMed

    Meylan, César M P; Cronin, John B; Oliver, Jon L; Hughes, Michael M G; Jidovtseff, Boris; Pinder, Shane

    2015-03-01

    The purpose of this study was to quantify the inter-session reliability of force-velocity-power profiling and estimated maximal strength in youth. Thirty-six males (11-15 years old) performed a ballistic supine leg press test at five randomized loads (80%, 100%, 120%, 140%, and 160% body mass) on three separate occasions. Peak and mean force, power, velocity, and peak displacement were collected with a linear position transducer attached to the weight stack. Mean values at each load were used to calculate different regression lines and estimate maximal strength, force, velocity, and power. All variables were found reliable (change in the mean [CIM] = - 1 to 14%; coefficient of variation [CV] = 3-18%; intraclass correlation coefficient [ICC] = 0.74-0.99), but were likely to benefit from a familiarization, apart from the unreliable maximal force/velocity ratio (CIM = 0-3%; CV = 23-25%; ICC = 0.35-0.54) and load at maximal power (CIM = - 1 to 2%; CV = 10-13%; ICC = 0.26-0.61). Isoinertial force-velocity-power profiling and maximal strength in youth can be assessed after a familiarization session. Such profiling may provide valuable insight into neuromuscular capabilities during growth and maturation and may be used to monitor specific training adaptations.

  2. A New Algorithm to Optimize Maximal Information Coefficient

    PubMed Central

    Luo, Feng; Yuan, Zheming

    2016-01-01

    The maximal information coefficient (MIC) captures dependences between paired variables, including both functional and non-functional relationships. In this paper, we develop a new method, ChiMIC, to calculate the MIC values. The ChiMIC algorithm uses the chi-square test to terminate grid optimization and then removes the restriction of maximal grid size limitation of original ApproxMaxMI algorithm. Computational experiments show that ChiMIC algorithm can maintain same MIC values for noiseless functional relationships, but gives much smaller MIC values for independent variables. For noise functional relationship, the ChiMIC algorithm can reach the optimal partition much faster. Furthermore, the MCN values based on MIC calculated by ChiMIC can capture the complexity of functional relationships in a better way, and the statistical powers of MIC calculated by ChiMIC are higher than those calculated by ApproxMaxMI. Moreover, the computational costs of ChiMIC are much less than those of ApproxMaxMI. We apply the MIC values tofeature selection and obtain better classification accuracy using features selected by the MIC values from ChiMIC. PMID:27333001

  3. Low Energy Dissipation Nano Device Research

    NASA Astrophysics Data System (ADS)

    Yu, Jenny

    2015-03-01

    The development of research on energy dissipation has been rapid in energy efficient area. Nano-material power FET is operated as an RF power amplifier, the transport is ballistic, noise is limited and power dissipation is minimized. The goal is Green-save energy by developing the Graphene and carbon nantube microwave and high performance devices. Higher performing RF amplifiers can have multiple impacts on broadly field, for example communication equipment, (such as mobile phone and RADAR); higher power density and lower power dissipation will improve spectral efficiency which translates into higher system level bandwidth and capacity for communications equipment. Thus, fundamental studies of power handling capabilities of new RF (nano)technologies can have broad, sweeping impact. Because it is critical to maximizing the power handling ability of grephene and carbon nanotube FET, the initial task focuses on measuring and understanding the mechanism of electrical breakdown. We aim specifically to determine how the breakdown voltage in graphene and nanotubes is related to the source-drain spacing, electrode material and thickness, and substrate, and thus develop reliable statistics on the breakdown mechanism and probability.

  4. A retrospective likelihood approach for efficient integration of multiple omics factors in case-control association studies.

    PubMed

    Balliu, Brunilda; Tsonaka, Roula; Boehringer, Stefan; Houwing-Duistermaat, Jeanine

    2015-03-01

    Integrative omics, the joint analysis of outcome and multiple types of omics data, such as genomics, epigenomics, and transcriptomics data, constitute a promising approach for powerful and biologically relevant association studies. These studies often employ a case-control design, and often include nonomics covariates, such as age and gender, that may modify the underlying omics risk factors. An open question is how to best integrate multiple omics and nonomics information to maximize statistical power in case-control studies that ascertain individuals based on the phenotype. Recent work on integrative omics have used prospective approaches, modeling case-control status conditional on omics, and nonomics risk factors. Compared to univariate approaches, jointly analyzing multiple risk factors with a prospective approach increases power in nonascertained cohorts. However, these prospective approaches often lose power in case-control studies. In this article, we propose a novel statistical method for integrating multiple omics and nonomics factors in case-control association studies. Our method is based on a retrospective likelihood function that models the joint distribution of omics and nonomics factors conditional on case-control status. The new method provides accurate control of Type I error rate and has increased efficiency over prospective approaches in both simulated and real data. © 2015 Wiley Periodicals, Inc.

  5. Predictive importance of anthropometric and training data in recreational male Ironman triathletes and marathon runners: comment on the study by Gianoli, et al. (2012).

    PubMed

    Burtscher, Martin; Gatterer, Hannes

    2013-04-01

    Anthropometric and training data have been reported as statistically significant predictors of race performance in endurance events. However, it is well established that physiological characteristics, i.e., maximal oxygen uptake (VO2max), the use of a high percentage of VO2max during sustained exercise, and work efficiency are predominant predictors of performance in those events. Thus, the essential issue is whether the anthropometric and training data give additional predictive power beyond these other measures.

  6. Biomarker selection for medical diagnosis using the partial area under the ROC curve

    PubMed Central

    2014-01-01

    Background A biomarker is usually used as a diagnostic or assessment tool in medical research. Finding an ideal biomarker is not easy and combining multiple biomarkers provides a promising alternative. Moreover, some biomarkers based on the optimal linear combination do not have enough discriminatory power. As a result, the aim of this study was to find the significant biomarkers based on the optimal linear combination maximizing the pAUC for assessment of the biomarkers. Methods Under the binormality assumption we obtain the optimal linear combination of biomarkers maximizing the partial area under the receiver operating characteristic curve (pAUC). Related statistical tests are developed for assessment of a biomarker set and of an individual biomarker. Stepwise biomarker selections are introduced to identify those biomarkers of statistical significance. Results The results of simulation study and three real examples, Duchenne Muscular Dystrophy disease, heart disease, and breast tissue example are used to show that our methods are most suitable biomarker selection for the data sets of a moderate number of biomarkers. Conclusions Our proposed biomarker selection approaches can be used to find the significant biomarkers based on hypothesis testing. PMID:24410929

  7. Using Maximal Isometric Force to Determine the Optimal Load for Measuring Dynamic Muscle Power

    NASA Technical Reports Server (NTRS)

    Spiering, Barry A.; Lee, Stuart M. C.; Mulavara, Ajitkumar P.; Bentley, Jason R.; Nash, Roxanne E.; Sinka, Joseph; Bloomberg, Jacob J.

    2009-01-01

    Maximal power output occurs when subjects perform ballistic exercises using loads of 30-50% of one-repetition maximum (1-RM). However, performing 1-RM testing prior to power measurement requires considerable time, especially when testing involves multiple exercises. Maximal isometric force (MIF), which requires substantially less time to measure than 1-RM, might be an acceptable alternative for determining the optimal load for power testing. PURPOSE: To determine the optimal load based on MIF for maximizing dynamic power output during leg press and bench press exercises. METHODS: Twenty healthy volunteers (12 men and 8 women; mean +/- SD age: 31+/-6 y; body mass: 72 +/- 15 kg) performed isometric leg press and bench press movements, during which MIF was measured using force plates. Subsequently, subjects performed ballistic leg press and bench press exercises using loads corresponding to 20%, 30%, 40%, 50%, and 60% of MIF presented in randomized order. Maximal instantaneous power was calculated during the ballistic exercise tests using force plates and position transducers. Repeated-measures ANOVA and Fisher LSD post hoc tests were used to determine the load(s) that elicited maximal power output. RESULTS: For the leg press power test, six subjects were unable to be tested at 20% and 30% MIF because these loads were less than the lightest possible load (i.e., the weight of the unloaded leg press sled assembly [31.4 kg]). For the bench press power test, five subjects were unable to be tested at 20% MIF because these loads were less than the weight of the unloaded aluminum bar (i.e., 11.4 kg). Therefore, these loads were excluded from analysis. A trend (p = 0.07) for a main effect of load existed for the leg press exercise, indicating that the 40% MIF load tended to elicit greater power output than the 60% MIF load (effect size = 0.38). A significant (p . 0.05) main effect of load existed for the bench press exercise; post hoc analysis indicated that the effect of load on power output was: 30% > 40% > 50% = 60%. CONCLUSION: Loads of 40% and 30% of MIF elicit maximal power output during dynamic leg presses and bench presses, respectively. These findings are similar to those obtained when loading is based on 1-RM.

  8. Responsive measures to prehabilitation in patients undergoing bowel resection surgery.

    PubMed

    Kim, Do Jun; Mayo, Nancy E; Carli, Franco; Montgomery, David L; Zavorsky, Gerald S

    2009-02-01

    Surgical patients often show physiological and metabolic distress, muscle weakness, and long hospital stays. Physical conditioning might help recovery. We attempted to identify the most responsive measure of aerobic fitness from a four-week pre-surgical aerobic exercise program (prehabilitation) in patients undergoing major bowel resection. Twenty-one subjects randomized two to one (exercise: control) scheduled for colorectal surgery. Fourteen subjects [Body Mass Index (BMI) = 27 +/- 6 kg/m(2); maximal oxygen uptake (VO(2max)) = 22 +/- 10 ml/kg/min] underwent 3.8 +/- 1.2 weeks (27 +/- 8 sessions) of progressive, structured pre-surgical aerobic exercise training at 40 to 65% of heart rate reserve (%HRR). Peak power output was the only maximal measure that was responsive to training [26 +/- 27%, Effects Size (ES) = 0.24; Standardized Response Mean (SRM) = 1.05; p < 0.05]. For the submaximal measures, heart rate and oxygen uptake during submaximal exercise was most responsive to training (decrease by 13% +/- 15%, ES = -0.24; SRM = -0.57; and 7% +/- 6%, ES = -0.40; SRM -0.97; p < 0.05) at an exercise intensity of 76 +/- 47 W. There was no change to maximal or submaximal measures in the control group. The distance walked over six minutes improved in both groups (by approximately 30 m), but the effect size and t-statistic were higher in the exercise group. Heart rate and oxygen uptake during submaximal exercise, and peak power output are the most responsive measures to four weeks of prehabilitation in subjects with low initial fitness.

  9. Statistical-QoS Guaranteed Energy Efficiency Optimization for Energy Harvesting Wireless Sensor Networks

    PubMed Central

    Cheng, Wenchi; Zhang, Hailin

    2017-01-01

    Energy harvesting, which offers a never-ending energy supply, has emerged as a prominent technology to prolong the lifetime and reduce costs for the battery-powered wireless sensor networks. However, how to improve the energy efficiency while guaranteeing the quality of service (QoS) for energy harvesting based wireless sensor networks is still an open problem. In this paper, we develop statistical delay-bounded QoS-driven power control policies to maximize the effective energy efficiency (EEE), which is defined as the spectrum efficiency under given specified QoS constraints per unit harvested energy, for energy harvesting based wireless sensor networks. For the battery-infinite wireless sensor networks, our developed QoS-driven power control policy converges to the Energy harvesting Water Filling (E-WF) scheme and the Energy harvesting Channel Inversion (E-CI) scheme under the very loose and stringent QoS constraints, respectively. For the battery-finite wireless sensor networks, our developed QoS-driven power control policy becomes the Truncated energy harvesting Water Filling (T-WF) scheme and the Truncated energy harvesting Channel Inversion (T-CI) scheme under the very loose and stringent QoS constraints, respectively. Furthermore, we evaluate the outage probabilities to theoretically analyze the performance of our developed QoS-driven power control policies. The obtained numerical results validate our analysis and show that our developed optimal power control policies can optimize the EEE over energy harvesting based wireless sensor networks. PMID:28832509

  10. Statistical-QoS Guaranteed Energy Efficiency Optimization for Energy Harvesting Wireless Sensor Networks.

    PubMed

    Gao, Ya; Cheng, Wenchi; Zhang, Hailin

    2017-08-23

    Energy harvesting, which offers a never-ending energy supply, has emerged as a prominent technology to prolong the lifetime and reduce costs for the battery-powered wireless sensor networks. However, how to improve the energy efficiency while guaranteeing the quality of service (QoS) for energy harvesting based wireless sensor networks is still an open problem. In this paper, we develop statistical delay-bounded QoS-driven power control policies to maximize the effective energy efficiency (EEE), which is defined as the spectrum efficiency under given specified QoS constraints per unit harvested energy, for energy harvesting based wireless sensor networks. For the battery-infinite wireless sensor networks, our developed QoS-driven power control policy converges to the Energy harvesting Water Filling (E-WF) scheme and the Energy harvesting Channel Inversion (E-CI) scheme under the very loose and stringent QoS constraints, respectively. For the battery-finite wireless sensor networks, our developed QoS-driven power control policy becomes the Truncated energy harvesting Water Filling (T-WF) scheme and the Truncated energy harvesting Channel Inversion (T-CI) scheme under the very loose and stringent QoS constraints, respectively. Furthermore, we evaluate the outage probabilities to theoretically analyze the performance of our developed QoS-driven power control policies. The obtained numerical results validate our analysis and show that our developed optimal power control policies can optimize the EEE over energy harvesting based wireless sensor networks.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eliazar, Iddo, E-mail: eliazar@post.tau.ac.il

    Rank distributions are collections of positive sizes ordered either increasingly or decreasingly. Many decreasing rank distributions, formed by the collective collaboration of human actions, follow an inverse power-law relation between ranks and sizes. This remarkable empirical fact is termed Zipf’s law, and one of its quintessential manifestations is the demography of human settlements — which exhibits a harmonic relation between ranks and sizes. In this paper we present a comprehensive statistical-physics analysis of rank distributions, establish that power-law and exponential rank distributions stand out as optimal in various entropy-based senses, and unveil the special role of the harmonic relation betweenmore » ranks and sizes. Our results extend the contemporary entropy-maximization view of Zipf’s law to a broader, panoramic, Gibbsian perspective of increasing and decreasing power-law and exponential rank distributions — of which Zipf’s law is one out of four pillars.« less

  12. Frequency and duration of interval training programs and changes in aerobic power

    NASA Technical Reports Server (NTRS)

    Fox, E. L.; Bartels, R. L.; Obrien, R.; Bason, R.; Mathews, D. K.; Billings, C. E.

    1975-01-01

    The present study was designed to ascertain whether a training frequency of 2 days/wk for a 7- and 13-wk interval training program would produce improvement in maximal aerobic power comparable to that obtained from 7- and 13-wk programs of the same intensity consisting of 4 training days/wk. After training, there was a significant increase in maximal aerobic power that was independent of both training frequency and duration. Maximal heart rate was significantly decreased following training. Submaximal aerobic power did not change with training, but submaximal heart rate decreased significantly with greater decreases the more frequent and the longer the training.

  13. Apparatus and method for maximizing power delivered by a photovoltaic array

    DOEpatents

    Muljadi, Eduard; Taylor, Roger W.

    1998-01-01

    A method and apparatus for maximizing the electric power output of a photovoltaic array connected to a battery where the voltage across the photovoltaic array is adjusted through a range of voltages to find the voltage across the photovoltaic array that maximizes the electric power generated by the photovoltaic array and then is held constant for a period of time. After the period of time has elapsed, the electric voltage across the photovoltaic array is again adjusted through a range of voltages and the process is repeated. The electric energy and the electric power generated by the photovoltaic array is delivered to the battery which stores the electric energy and the electric power for later delivery to a load.

  14. Apparatus and method for maximizing power delivered by a photovoltaic array

    DOEpatents

    Muljadi, E.; Taylor, R.W.

    1998-05-05

    A method and apparatus for maximizing the electric power output of a photovoltaic array connected to a battery where the voltage across the photovoltaic array is adjusted through a range of voltages to find the voltage across the photovoltaic array that maximizes the electric power generated by the photovoltaic array and then is held constant for a period of time. After the period of time has elapsed, the electric voltage across the photovoltaic array is again adjusted through a range of voltages and the process is repeated. The electric energy and the electric power generated by the photovoltaic array is delivered to the battery which stores the electric energy and the electric power for later delivery to a load. 20 figs.

  15. Efficiency of a thermodynamic motor at maximum power

    NASA Astrophysics Data System (ADS)

    Moreau, M.; Gaveau, B.; Schulman, L. S.

    2012-02-01

    Several recent theories address the efficiency of a macroscopic thermodynamic motor at maximum power and question the so-called Curzon-Ahlborn (CA) efficiency. Considering the entropy exchanges and productions in an n-sources motor, we study the maximization of its power and show that the controversies are partly due to some imprecision in the maximization variables. When power is maximized with respect to the system temperatures, these temperatures are proportional to the square root of the corresponding source temperatures, which leads to the CA formula for a bithermal motor. On the other hand, when power is maximized with respect to the transition durations, the Carnot efficiency of a bithermal motor admits the CA efficiency as a lower bound, which is attained if the duration of the adiabatic transitions can be neglected. Additionally, we compute the energetic efficiency, or “sustainable efficiency,” which can be defined for n sources, and we show that it has no other universal upper bound than 1, but that in certain situations, which are favorable for power production, it does not exceed ½.

  16. Efficiency of a thermodynamic motor at maximum power.

    PubMed

    Moreau, M; Gaveau, B; Schulman, L S

    2012-02-01

    Several recent theories address the efficiency of a macroscopic thermodynamic motor at maximum power and question the so-called Curzon-Ahlborn (CA) efficiency. Considering the entropy exchanges and productions in an n-sources motor, we study the maximization of its power and show that the controversies are partly due to some imprecision in the maximization variables. When power is maximized with respect to the system temperatures, these temperatures are proportional to the square root of the corresponding source temperatures, which leads to the CA formula for a bithermal motor. On the other hand, when power is maximized with respect to the transition durations, the Carnot efficiency of a bithermal motor admits the CA efficiency as a lower bound, which is attained if the duration of the adiabatic transitions can be neglected. Additionally, we compute the energetic efficiency, or "sustainable efficiency," which can be defined for n sources, and we show that it has no other universal upper bound than 1, but that in certain situations, which are favorable for power production, it does not exceed ½. © 2012 American Physical Society

  17. Optimization of the Heat Exchangers of a Thermoelectric Generation System

    NASA Astrophysics Data System (ADS)

    Martínez, A.; Vián, J. G.; Astrain, D.; Rodríguez, A.; Berrio, I.

    2010-09-01

    The thermal resistances of the heat exchangers have a strong influence on the electric power produced by a thermoelectric generator. In this work, the heat exchangers of a thermoelectric generator have been optimized in order to maximize the electric power generated. This thermoelectric generator harnesses heat from the exhaust gas of a domestic gas boiler. Statistical design of experiments was used to assess the influence of five factors on both the electric power generated and the pressure drop in the chimney: height of the generator, number of modules per meter of generator height, length of the fins of the hot-side heat exchanger (HSHE), length of the gap between fins of the HSHE, and base thickness of the HSHE. The electric power has been calculated using a computational model, whereas Fluent computational fluid dynamics (CFD) has been used to obtain the thermal resistances of the heat exchangers and the pressure drop. Finally, the thermoelectric generator has been optimized, taking into account the restrictions on the pressure drop.

  18. Enhancing performance during inclined loaded walking with a powered ankle-foot exoskeleton.

    PubMed

    Galle, Samuel; Malcolm, Philippe; Derave, Wim; De Clercq, Dirk

    2014-11-01

    A simple ankle-foot exoskeleton that assists plantarflexion during push-off can reduce the metabolic power during walking. This suggests that walking performance during a maximal incremental exercise could be improved with an exoskeleton if the exoskeleton is still efficient during maximal exercise intensities. Therefore, we quantified the walking performance during a maximal incremental exercise test with a powered and unpowered exoskeleton: uphill walking with progressively higher weights. Nine female subjects performed two incremental exercise tests with an exoskeleton: 1 day with (powered condition) and another day without (unpowered condition) plantarflexion assistance. Subjects walked on an inclined treadmill (15%) at 5 km h(-1) and 5% of body weight was added every 3 min until exhaustion. At volitional termination no significant differences were found between the powered and unpowered condition for blood lactate concentration (respectively, 7.93 ± 2.49; 8.14 ± 2.24 mmol L(-1)), heart rate (respectively, 190.00 ± 6.50; 191.78 ± 6.50 bpm), Borg score (respectively, 18.57 ± 0.79; 18.93 ± 0.73) and VO₂ peak (respectively, 40.55 ± 2.78; 40.55 ± 3.05 ml min(-1) kg(-1)). Thus, subjects were able to reach the same (near) maximal effort in both conditions. However, subjects continued the exercise test longer in the powered condition and carried 7.07 ± 3.34 kg more weight because of the assistance of the exoskeleton. Our results show that plantarflexion assistance during push-off can increase walking performance during a maximal exercise test as subjects were able to carry more weight. This emphasizes the importance of acting on the ankle joint in assistive devices and the potential of simple ankle-foot exoskeletons for reducing metabolic power and increasing weight carrying capability, even during maximal intensities.

  19. Does power indicate capacity? 30-s Wingate anaerobic test vs. maximal accumulated O2 deficit.

    PubMed

    Minahan, C; Chia, M; Inbar, O

    2007-10-01

    The purpose of this study was to evaluate the relationship between anaerobic power and capacity. Seven men and seven women performed a 30-s Wingate Anaerobic Test on a cycle ergometer to determine peak power, mean power, and the fatigue index. Subjects also cycled at a work rate predicted to elicit 120 % of peak oxygen uptake to exhaustion to determine the maximal accumulated O (2) deficit. Peak power and the maximal accumulated O (2) deficit were significantly correlated (r = 0.782, p = 0.001). However, when the absolute difference in exercise values between groups (men and women) was held constant using a partial correlation, the relationship diminished (r = 0.531, p = 0.062). In contrast, we observed a significant correlation between fatigue index and the maximal accumulated O (2) deficit when controlling for gender (r = - 0.597, p = 0.024) and the relationship remained significant when values were expressed relative to active muscle mass. A higher anaerobic power does not indicate a greater anaerobic capacity. Furthermore, we suggest that the ability to maintain power output during a 30-s cycle sprint is related to anaerobic capacity.

  20. A Lyapunov based approach to energy maximization in renewable energy technologies

    NASA Astrophysics Data System (ADS)

    Iyasere, Erhun

    This dissertation describes the design and implementation of Lyapunov-based control strategies for the maximization of the power captured by renewable energy harnessing technologies such as (i) a variable speed, variable pitch wind turbine, (ii) a variable speed wind turbine coupled to a doubly fed induction generator, and (iii) a solar power generating system charging a constant voltage battery. First, a torque control strategy is presented to maximize wind energy captured in variable speed, variable pitch wind turbines at low to medium wind speeds. The proposed strategy applies control torque to the wind turbine pitch and rotor subsystems to simultaneously control the blade pitch and tip speed ratio, via the rotor angular speed, to an optimum point at which the capture efficiency is maximum. The control method allows for aerodynamic rotor power maximization without exact knowledge of the wind turbine model. A series of numerical results show that the wind turbine can be controlled to achieve maximum energy capture. Next, a control strategy is proposed to maximize the wind energy captured in a variable speed wind turbine, with an internal induction generator, at low to medium wind speeds. The proposed strategy controls the tip speed ratio, via the rotor angular speed, to an optimum point at which the efficiency constant (or power coefficient) is maximal for a particular blade pitch angle and wind speed by using the generator rotor voltage as a control input. This control method allows for aerodynamic rotor power maximization without exact wind turbine model knowledge. Representative numerical results demonstrate that the wind turbine can be controlled to achieve near maximum energy capture. Finally, a power system consisting of a photovoltaic (PV) array panel, dc-to-dc switching converter, charging a battery is considered wherein the environmental conditions are time-varying. A backstepping PWM controller is developed to maximize the power of the solar generating system. The controller tracks a desired array voltage, designed online using an incremental conductance extremum-seeking algorithm, by varying the duty cycle of the switching converter. The stability of the control algorithm is demonstrated by means of Lyapunov analysis. Representative numerical results demonstrate that the grid power system can be controlled to track the maximum power point of the photovoltaic array panel in varying atmospheric conditions. Additionally, the performance of the proposed strategy is compared to the typical maximum power point tracking (MPPT) method of perturb and observe (P&O), where the converter dynamics are ignored, and is shown to yield better results.

  1. Physiological Interpretation of the Slope during an Isokinetic Fatigue Test.

    PubMed

    Bosquet, L; Gouadec, K; Berryman, N; Duclos, C; Gremeaux, V; Croisier, J-L

    2015-07-01

    To assess the relationship between selected measures (the slope and average performance) obtained during a high intensity isokinetic fatigue test of the knee (FAT) and relevant measures of anaerobic and aerobic capacities. 20 well-trained cyclists performed 3 randomly ordered sessions involving a FAT consisting in 30 reciprocal maximal concentric contractions of knee flexors and extensors at 180°.s(-1), a maximal continuous graded exercise test (GXT), and a Wingate anaerobic test (WAnT). The slope calculated from peak torque (PT) and total work (TW) of knee extensors was highly associated to maximal PT (r=-0.86) and maximal TW (r=-0.87) measured during FAT, and moderately associated to peak power output measured during the WAnT (r=-0.64 to -0.71). Average PT and average TW were highly associated to maximal PT (r=0.93) and maximal TW (r=0.96), to mean power output measured during WAnT (r=0.83-0.90) and moderately associated to maximal oxygen uptake (0.58-0.67). In conclusion, the slope is mainly determined by maximal anaerobic power, while average performance is a composite measure depending on both aerobic and anaerobic energy systems according to proportions that are determined by the duration of the test. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Vision in relation to lower extremity deficit in older women: cross-sectional and longitudinal study.

    PubMed

    Kulmala, Jenni; Sipilä, Sarianna; Tiainen, Kristina; Pärssinen, Olavi; Koskenvuo, Markku; Kaprio, Jaakko; Rantanen, Taina

    2012-10-01

    Vision problems are common experiences within the older population. This study aimed to examine the association between vision and lower extremity impairment. 434 women aged 63-75 participated in visual acuity (VA) measurements at baseline and 313 persons at three-year follow-up. Measurements of lower extremity function included maximal isometric knee extension strength, leg extension power, maximal walking speed and standing balance. At baseline, knee extension strength was lower among participants with visual impairment (VI) (273.2±6.4 N) compared to those with good vision (306.5±5.9 N, p<0.001) as well as leg extension power (95.2±2.7 W vs 104.2±2.6 W, p=0.009) and maximal walking speed (1.6±0.02 m/s vs 1.8±0.03 m/s, p<0.001). Higher velocity moment among persons with VI (53.5±2.7 mm²/s vs 42.7±1.4 mm²/s, p<0.001) indicated that persons with VI had poorer balance compared to persons with good vision. Decreased isometric knee extension strength (OR 1.26, 95% CI 1.09-1.45), poorer standing balance (OR 1.16, 95% CI 1.00-1.35) as well as lower maximal walking speed (OR 1.34, 95% CI 1.13-1.59) were associated with VI in the logistic regression models. Additionally, the association between poorer leg extension power and VI (OR 1.14, 95% CI 0.99-1.31) was of borderline statistical significance. In longitudinal analyses, VI did not predict decline in lower extremity function. Lower extremity impairment was associated with VI among relatively healthy older women. However, change in lower extremity function was quite similar between the vision groups. It is possible that decreased VA may be a marker of underlying systemic factors or the aging process, which lead to poorer functional capacity, or there may be shared background factors, which lead to decreased vision and lower extremity impairment.

  3. Short-Term Effects of Rolling Massage on Energy Cost of Running and Power of the Lower Limbs.

    PubMed

    Giovanelli, Nicola; Vaccari, Filippo; Floreani, Mirco; Rejc, Enrico; Copetti, Jasmine; Garra, Marco; Biasutti, Lea; Lazzer, Stefano

    2018-05-10

    Self-myofascial release (SMFR) is a type of self-massage that is becoming popular among athletes. However, SMFR effects on running performance have not been investigated yet. The aim of the present study was to evaluate the effects of SMFR on cost of running (Cr). In addition, we evaluated the effects of SMFR on lower limbs muscle power. The measurement of Cr and lower limb muscle power during squat jump (SJ) and counter movement jump (CMJ) were performed before (PRE), immediately after (POST) and 3hours after (POST 3h) a SMFR protocol (experimental condition). In the "control condition" testing session, the same measurements were performed without undergoing the SMFR protocol. Experimental and control conditions were tested in a randomized order. Cr at POST trended to increase as compared to PRE (+6.2±8.3%, p=0.052), while at POST 3h Cr was restored to PRE values (+0.28±9.5%, p=0.950). In the experimental condition, no significant "Time" effect was observed for maximal power exerted during SJ. On the other hand, maximal power exerted during CMJ at POST and POST 3h was significantly higher than that observed at PRE (+7.9±6.3%, p=0.002; and +10.0±8.7%, p=0.004, respectively). The rate of force development measured during CMJ also increased after SMFR, reaching statistical significance at 200 ms from force onset at POST 3h (+38.9%, p=0.024). an acute use of foam roller for SMFR performed immediately prior to running may negatively affect the endurance running performance, while its use should be added before explosive motor performances that include stretch-shortening cycles.

  4. Effect of constitutive inactivation of the myostatin gene on the gain in muscle strength during postnatal growth in two murine models.

    PubMed

    Stantzou, Amalia; Ueberschlag-Pitiot, Vanessa; Thomasson, Remi; Furling, Denis; Bonnieu, Anne; Amthor, Helge; Ferry, Arnaud

    2017-02-01

    The effect of constitutive inactivation of the gene encoding myostatin on the gain in muscle performance during postnatal growth has not been well characterized. We analyzed 2 murine myostatin knockout (KO) models, (i) the Lee model (KO Lee ) and (ii) the Grobet model (KO Grobet ), and measured the contraction of tibialis anterior muscle in situ. Absolute maximal isometric force was increased in 6-month-old KO Lee and KO Grobet mice, as compared to wild-type mice. Similarly, absolute maximal power was increased in 6-month-old KO Lee mice. In contrast, specific maximal force (relative maximal force per unit of muscle mass was decreased in all 6-month-old male and female KO mice, except in 6-month-old female KO Grobet mice, whereas specific maximal power was reduced only in male KO Lee mice. Genetic inactivation of myostatin increases maximal force and power, but in return it reduces muscle quality, particularly in male mice. Muscle Nerve 55: 254-261, 2017. © 2016 Wiley Periodicals, Inc.

  5. Transformative Advances in DDDAS with Application to Space Weather Monitoring

    DTIC Science & Technology

    2015-10-01

    subsystems, including power and communications subsystems. In addition, a study of photovoltaic power generation constraints due to spacecraft solar...estimation. Automatica, 23:775–778, 1987. [61] D. Y. Lee, J. W. Cutler, J. Mancewicz, and A. J. Ridley. Maximizing photovoltaic power generation of a space...Maximizing photovoltaic power generation of a space-dart configured satellite. Acta Astronautica, 111:283–299, 2015. A. V. Morozov, A. J. Ridley, D. S

  6. The rate of lactate removal after maximal exercise: the effect of intensity during active recovery.

    PubMed

    Riganas, C S; Papadopoulou, Z; Psichas, N; Skoufas, D; Gissis, I; Sampanis, M; Paschalis, V; Vrabas, I S

    2015-10-01

    The aim of the present investigation was to determine the greater rate of lactate removal after a maximal rowing test using different intensities during active recovery. Thirty elite male rowers performed a simulated incremental exercise protocol on rowing ergometer to determine their maximal oxygen uptake and they divided into three equal sized group according to the type of the recovery that followed the assessment. The first group (N.=10) subjected to 20 min of passive recovery, while the second (N.=10) and the third (N.=10) groups performed 20 min of active recovery using the 25% and the 50% of each individual’s maximal power output, respectively. During the recovery period, every two min were performed measurements for the assessment of blood lactate, oxygen consumption and heart rate (HR). It was found that after 10 min of active recovery at 50% and 25% of maximal power output lactate concentration reduced by 43% and 15%, respectively, while during passive recovery lactate concentration found to be slightly elevated by 1%. It was also found that during recovery period, HR, oxygen consumption and pulmonary ventilation was significant elevated at higher exercise intensity compared to lower exercise intensity and passive recovery. It is concluded that in elite male rowers the active recovery provided higher rate of lactate removal compared to passive recovery. Moreover, active recovery at 50% of maximal power output had better results in lactate clearance compared to the active recovery of lower intensity (25% of maximal power output).

  7. Maximal strength and power assessment in novice weight trainers.

    PubMed

    Cronin, John B; Henderson, Melanie E

    2004-02-01

    The purpose of this study was to investigate whether changes in maximal strength and power output occurred over time in the absence of strength and power training in novice weight trainers. It also investigated whether differences existed between upper- and lower-body assessments and unilateral and bilateral assessments. The power output and maximal strength (1 repetition maximum [1RM]) of 10 male novice subjects were measured on 4 occasions, each assessment 7-10 days apart. The exercises used to measure the upper- and lower-body strength and power outputs were the bench press and supine squat, respectively. Significant (p < 0.05) changes in unilateral (9.8-16.8%) and bilateral 1RM (6.8-15.0%) leg strength were found, the first assessment being significantly different from all other assessments and assessment 2 significantly different from assessment 4. Changes in the upper body (10-13.6%) were also observed. The only significant difference was between assessment 1 and the other testing occasions. No differences in power output were observed for both the upper and lower body during the study. It would seem that considerable changes in maximal strength occur rapidly and in the absence of any formal strength training program in novice weight trainers.

  8. Somatotype variables related to strength and power output in male basketball players.

    PubMed

    Buśko, Krzysztof; Pastuszak, Anna; Lipińska, Monika; Lipińska, Marta; Gryko, Karol

    2017-01-01

    The purpose of this study was to investigate the relationship between somatotype, muscular strength, power output measured in maximal cycle ergometer exercise bouts, and maximal power output and height of rise of the body mass centre (jump height) measured in akimbo counter movement jump (ACMJ), counter movement jump (CMJ) and spike jump (SPJ), in male basketball players. Thirteen male basketball players (second division, age 19.4 ± 0.8 years, body height 192.9 ± 5.6 cm, body mass 88.8 ± 8.6 kg, training experience 9.3 ± 0.8 years) participated in the study. Somatotype was determined using the Heath-Carter method. Maximal joint torques were measured under static conditions. Power output was measured in 2 maximal cycle ergometer exercise bouts, 10 seconds each, with increasing external loads equal to 7.5 and 10.0% of the body weight (BW). All jump trials (ACMJ, CMJ and SPJ) were performed on a force plate. The mean somatotype of basketball players amounted to: 2.8-4.2-3.2. The sum of the joint torques for left and right lower extremities (0.613), trunk (0.631) and all six measured muscle groups (0.647) were significantly correlated (p < 0.05) with the mesomorphic component. Endomorphic, mesomorphic and ectomorphic components were correlated insignificantly with values of maximal power and height of jump during ACMJ, CMJ and SPJ trials. The power output measured in maximal cycle ergometer exercise bouts with increasing external loads was significantly correlated (p < 0.05) with mesomorphy and ectomorphy. It can be assumed that basketball players' anthropometric characteristics can influence their level of performance but it is not a decisive factor.

  9. Percolation under noise: Detecting explosive percolation using the second-largest component

    NASA Astrophysics Data System (ADS)

    Viles, Wes; Ginestet, Cedric E.; Tang, Ariana; Kramer, Mark A.; Kolaczyk, Eric D.

    2016-05-01

    We consider the problem of distinguishing between different rates of percolation under noise. A statistical model of percolation is constructed allowing for the birth and death of edges as well as the presence of noise in the observations. This graph-valued stochastic process is composed of a latent and an observed nonstationary process, where the observed graph process is corrupted by type-I and type-II errors. This produces a hidden Markov graph model. We show that for certain choices of parameters controlling the noise, the classical (Erdős-Rényi) percolation is visually indistinguishable from a more rapid form of percolation. In this setting, we compare two different criteria for discriminating between these two percolation models, based on the interquartile range (IQR) of the first component's size, and on the maximal size of the second-largest component. We show through data simulations that this second criterion outperforms the IQR of the first component's size, in terms of discriminatory power. The maximal size of the second component therefore provides a useful statistic for distinguishing between different rates of percolation, under physically motivated conditions for the birth and death of edges, and under noise. The potential application of the proposed criteria for the detection of clinically relevant percolation in the context of applied neuroscience is also discussed.

  10. Muscle coordination changes during intermittent cycling sprints.

    PubMed

    Billaut, François; Basset, Fabien A; Falgairette, Guy

    2005-06-03

    Maximal muscle power is reported to decrease during explosive cyclical exercises owing to metabolic disturbances, muscle damage, and adjustments in the efferent neural command. The aim of the present study was to analyze the influence of inter-muscle coordination in fatigue occurrence during 10 intermittent 6-s cycling sprints, with 30-s recovery through electromyographic activity (EMG). Results showed a decrease in peak power output with sprint repetitions (sprint 1 versus sprint 10: -11%, P<0.01) without any significant modifications in the integrated EMG. The timing between the knee extensor and the flexor EMG activation onsets was reduced in sprint 10 (sprint 1 versus sprint 10: -90.2 ms, P<0.05), owing to an earlier antagonist activation with fatigue occurrence. In conclusion, the maximal power output, developed during intermittent cycling sprints of short duration, decreased possibly due to the inability of muscles to maintain maximal force. This reduction in maximal power output occurred in parallel to changes in the muscle coordination pattern after fatigue.

  11. Optimal Loading for Maximizing Power During Sled-Resisted Sprinting.

    PubMed

    Cross, Matt R; Brughelli, Matt; Samozino, Pierre; Brown, Scott R; Morin, Jean-Benoit

    2017-09-01

    To ascertain whether force-velocity-power relationships could be compiled from a battery of sled-resisted overground sprints and to clarify and compare the optimal loading conditions for maximizing power production for different athlete cohorts. Recreational mixed-sport athletes (n = 12) and sprinters (n = 15) performed multiple trials of maximal sprints unloaded and towing a selection of sled masses (20-120% body mass [BM]). Velocity data were collected by sports radar, and kinetics at peak velocity were quantified using friction coefficients and aerodynamic drag. Individual force-velocity and power-velocity relationships were generated using linear and quadratic relationships, respectively. Mechanical and optimal loading variables were subsequently calculated and test-retest reliability assessed. Individual force-velocity and power-velocity relationships were accurately fitted with regression models (R 2 > .977, P < .001) and were reliable (ES = 0.05-0.50, ICC = .73-.97, CV = 1.0-5.4%). The normal loading that maximized peak power was 78% ± 6% and 82% ± 8% of BM, representing a resistance of 3.37 and 3.62 N/kg at 4.19 ± 0.19 and 4.90 ± 0.18 m/s (recreational athletes and sprinters, respectively). Optimal force and normal load did not clearly differentiate between cohorts, although sprinters developed greater maximal power (17.2-26.5%, ES = 0.97-2.13, P < .02) at much greater velocities (16.9%, ES = 3.73, P < .001). Mechanical relationships can be accurately profiled using common sled-training equipment. Notably, the optimal loading conditions determined in this study (69-96% of BM, dependent on friction conditions) represent much greater resistance than current guidelines (~7-20% of BM). This method has potential value in quantifying individualized training parameters for optimized development of horizontal power.

  12. The Effect of Long-Term Therapeutics, Prophylaxis and Screening Techniques on Aircrew Medical Standards.

    DTIC Science & Technology

    1981-03-01

    percentage of fat , maximal aerobic power, serum concentrations of triglycerides, total cholesterol and HDL cholesterol. This information is obtained fr-m each...drinkinq and physical activity related to health parameters su-h as wei ,iht , body fat content, maximal aerobic T1ewer and serum concentrations of...subjects, and the body fat is estimated from the body density (4). 3. The maximal aerobic power is assessed indirectly according to the method of Astrand

  13. Relationships between maximal anaerobic power of the arms and legs and javelin performance.

    PubMed

    Bouhlel, E; Chelly, M S; Tabka, Z; Shephard, R

    2007-06-01

    The aim of this study was to examine relationships between maximal anaerobic power, as measured by leg and arm force-velocity tests, estimates of local muscle volume and javelin performance. Ten trained national level male javelin throwers (mean age 19.6+/- 2 years) participated in this study. Maximal anaerobic power, maximal force and maximal velocity were measured during leg (Wmax-L) and arm (Wmax-A) force-velocity tests, performed on appropriately modified forms of Monark cycle ergometer. Estimates of leg and arm muscle volume were made using a standard anthropometric kit. Maximal force of the leg (Fmax-L) was significantly correlated with estimated leg muscle volume (r=0.71, P<0.05). Wmax-L and Wmax-A were both significantly correlated with javelin performance (r=0.76, P<0.01; r=0.71, P <0.05, respectively). Maximal velocity of the leg (Vmax-L) was also significantly correlated with throwing performance (r=0.83; P<0.001). Wmax of both legs and arms were significantly correlated with javelin performance, the closest correlation being for Wmax-L; this emphasizes the importance of the leg muscles in this sport. Fmax-L and Vmax-L were related to muscle volume and to javelin performance, respectively. Force-velocity testing may have value in regulating conditioning and rehabilitation in sports involving throwing.

  14. Changes in aerobic power of women, ages 20-64 yr

    NASA Technical Reports Server (NTRS)

    Jackson, A. S.; Wier, L. T.; Ayers, G. W.; Beard, E. F.; Stuteville, J. E.; Blair, S. N.

    1996-01-01

    This study quantified and compared the cross-sectional and longitudinal influence of age, self-report physical activity (SR-PA), and body composition (%fat) on the decline of maximal aerobic power (VO2peak) of women. The cross-sectional sample consisted of 409 healthy women, ages 20-64 yr. The 43 women of the longitudinal sample were from the same population and examined twice, the mean time between tests was 3.7 (+/-2.2) yr. Peak oxygen uptake was determined by indirect calorimetry during a maximal treadmill test. The zero-order correlation of -0.742 between VO2peak and %fat was significantly (P < 0.05) higher then the SR-PA (r = 0.626) and age correlations (r = -0.633). Linear regression defined the cross-sectional age-related decline in VO2peak at 0.537 ml.kg-1.min-1.yr-1. Multiple regression analysis (R = 0.851) showed that adding %fat and SR-PA and their interaction to the regression model reduced the age regression weight of -0.537, to -0.265 ml.kg-1.min-1.yr-1. Statistically controlling for time differences between tests, general linear models analysis showed that longitudinal changes in aerobic power were due to independent changes in %fat and SR-PA, confirming the cross-sectional results. These findings are consistent with men's data from the same lab showing that about 50% of the cross-sectional age-related decline in VO2peak was due to %fat and SR-PA.

  15. Esophageal varices on computed tomography and subsequent variceal hemorrhage.

    PubMed

    Somsouk, Ma; To'o, Katherine; Ali, Mujtaba; Vittinghoff, Eric; Yeh, Benjamin M; Yee, Judy; Monto, Alex; Inadomi, John M; Aslam, Rizwan

    2014-04-01

    Endoscopy is recommended to screen for esophageal varices in patients with cirrhosis. The objective of this study was to identify features on abdominal CT imaging associated variceal hemorrhage (VH). A case-control study was performed among patients with cirrhosis who had a CT scan. Consecutive patients who experienced VH were included as cases, and patients without VH served as controls. Two radiologists recorded the maximal esophageal varix diameter in addition to other measures of portal hypertension at CT. The most powerful CT parameter associated with VH was the esophageal varix diameter (5.8 vs. 2.7 mm, p < 0.001; adjusted OR 1.84 per mm, p = 0.009). 63% of individuals with VH had a maximal varix diameter ≥5 mm compared to 7.5% of cirrhotic patients without VH (p < 0.001). In contrast, the proportion of individuals whose largest varix was <3 mm was 7.4% among VH cases compared to 54.7% among controls (p = 0.001). The varix diameter powerfully discriminated those with and without VH (C-statistic 0.84). A large esophageal varix diameter is strongly associated with subsequent VH. A threshold of <3 and ≥5 mm appears to identify patients with cirrhosis at low and high risk for hemorrhage.

  16. Esophageal varices on computed tomography and subsequent variceal hemorrhage

    PubMed Central

    Somsouk, Ma; To'o, Katherine; Ali, Mujtaba; Vittinghoff, Eric; Yeh, Benjamin M.; Yee, Judy; Monto, Alex; Inadomi, John M.; Aslam, Rizwan

    2014-01-01

    Purpose Endoscopy is recommended to screen for esophageal varices in patients with cirrhosis. The objective of this study was to identify features on abdominal CT imaging associated variceal hemorrhage (VH). Methods A case–control study was performed among patients with cirrhosis who had a CT scan. Consecutive patients who experienced VH were included as cases, and patients without VH served as controls. Two radiologists recorded the maximal esophageal varix diameter in addition to other measures of portal hypertension at CT. Results The most powerful CT parameter associated with VH was the esophageal varix diameter (5.8 vs. 2.7 mm, p < 0.001; adjusted OR 1.84 per mm, p = 0.009). 63% of individuals with VH had a maximal varix diameter ≥5 mm compared to 7.5% of cirrhotic patients without VH (p < 0.001). In contrast, the proportion of individuals whose largest varix was <3 mm was 7.4% among VH cases compared to 54.7% among controls (p = 0.001). The varix diameter powerfully discriminated those with and without VH (C-statistic 0.84). Conclusions A large esophageal varix diameter is strongly associated with subsequent VH. A threshold of <3 and ≥5 mm appears to identify patients with cirrhosis at low and high risk for hemorrhage. PMID:24366107

  17. Geometric Heat Engines Featuring Power that Grows with Efficiency.

    PubMed

    Raz, O; Subaşı, Y; Pugatch, R

    2016-04-22

    Thermodynamics places a limit on the efficiency of heat engines, but not on their output power or on how the power and efficiency change with the engine's cycle time. In this Letter, we develop a geometrical description of the power and efficiency as a function of the cycle time, applicable to an important class of heat engine models. This geometrical description is used to design engine protocols that attain both the maximal power and maximal efficiency at the fast driving limit. Furthermore, using this method, we also prove that no protocol can exactly attain the Carnot efficiency at nonzero power.

  18. Neuromuscular fatigue following constant versus variable-intensity endurance cycling in triathletes.

    PubMed

    Lepers, R; Theurel, J; Hausswirth, C; Bernard, T

    2008-07-01

    The aim of this study was to determine whether or not variable power cycling produced greater neuromuscular fatigue of knee extensor muscles than constant power cycling at the same mean power output. Eight male triathletes (age: 33+/-5 years, mass: 74+/-4 kg, VO2max: 62+/-5 mL kg(-1) min(-1), maximal aerobic power: 392+/-17 W) performed two 30 min trials on a cycle ergometer in a random order. Cycling exercise was performed either at a constant power output (CP) corresponding to 75% of the maximal aerobic power (MAP) or a variable power output (VP) with alternating +/-15%, +/-5%, and +/-10% of 75% MAP approximately every 5 min. Maximal voluntary contraction (MVC) torque, maximal voluntary activation level and excitation-contraction coupling process of knee extensor muscles were evaluated before and immediately after the exercise using the technique of electrically evoked contractions (single and paired stimulations). Oxygen uptake, ventilation and heart rate were also measured at regular intervals during the exercise. Averaged metabolic variables were not significantly different between the two conditions. Similarly, reductions in MVC torque (approximately -11%, P<0.05) after cycling were not different (P>0.05) between CP and VP trials. The magnitude of central and peripheral fatigue was also similar at the end of the two cycling exercises. It is concluded that, following 30 min of endurance cycling, semi-elite triathletes experienced no additional neuromuscular fatigue by varying power (from +/-5% to 15%) compared with a protocol that involved a constant power.

  19. Speckle-metric-optimization-based adaptive optics for laser beam projection and coherent beam combining.

    PubMed

    Vorontsov, Mikhail; Weyrauch, Thomas; Lachinova, Svetlana; Gatz, Micah; Carhart, Gary

    2012-07-15

    Maximization of a projected laser beam's power density at a remotely located extended object (speckle target) can be achieved by using an adaptive optics (AO) technique based on sensing and optimization of the target-return speckle field's statistical characteristics, referred to here as speckle metrics (SM). SM AO was demonstrated in a target-in-the-loop coherent beam combining experiment using a bistatic laser beam projection system composed of a coherent fiber-array transmitter and a power-in-the-bucket receiver. SM sensing utilized a 50 MHz rate dithering of the projected beam that provided a stair-mode approximation of the outgoing combined beam's wavefront tip and tilt with subaperture piston phases. Fiber-integrated phase shifters were used for both the dithering and SM optimization with stochastic parallel gradient descent control.

  20. Limit order placement as an utility maximization problem and the origin of power law distribution of limit order prices

    NASA Astrophysics Data System (ADS)

    Lillo, F.

    2007-02-01

    I consider the problem of the optimal limit order price of a financial asset in the framework of the maximization of the utility function of the investor. The analytical solution of the problem gives insight on the origin of the recently empirically observed power law distribution of limit order prices. In the framework of the model, the most likely proximate cause of this power law is a power law heterogeneity of traders' investment time horizons.

  1. Performance analysis of ‘Perturb and Observe’ and ‘Incremental Conductance’ MPPT algorithms for PV system

    NASA Astrophysics Data System (ADS)

    Lodhi, Ehtisham; Lodhi, Zeeshan; Noman Shafqat, Rana; Chen, Fieda

    2017-07-01

    Photovoltaic (PV) system usually employed The Maximum power point tracking (MPPT) techniques for increasing its efficiency. The performance of the PV system perhaps boosts by controlling at its apex point of power, in this way maximal power can be given to load. The proficiency of a PV system usually depends upon irradiance, temperature and array architecture. PV array shows a non-linear style for V-I curve and maximal power point on V-P curve also varies with changing environmental conditions. MPPT methods grantees that a PV module is regulated at reference voltage and to produce entire usage of the maximal output power. This paper gives analysis between two widely employed Perturb and Observe (P&O) and Incremental Conductance (INC) MPPT techniques. Their performance is evaluated and compared through theoretical analysis and digital simulation on the basis of response time and efficiency under varying irradiance and temperature condition using Matlab/Simulink.

  2. Direct power comparisons between simple LOD scores and NPL scores for linkage analysis in complex diseases.

    PubMed

    Abreu, P C; Greenberg, D A; Hodge, S E

    1999-09-01

    Several methods have been proposed for linkage analysis of complex traits with unknown mode of inheritance. These methods include the LOD score maximized over disease models (MMLS) and the "nonparametric" linkage (NPL) statistic. In previous work, we evaluated the increase of type I error when maximizing over two or more genetic models, and we compared the power of MMLS to detect linkage, in a number of complex modes of inheritance, with analysis assuming the true model. In the present study, we compare MMLS and NPL directly. We simulated 100 data sets with 20 families each, using 26 generating models: (1) 4 intermediate models (penetrance of heterozygote between that of the two homozygotes); (2) 6 two-locus additive models; and (3) 16 two-locus heterogeneity models (admixture alpha = 1.0,.7,.5, and.3; alpha = 1.0 replicates simple Mendelian models). For LOD scores, we assumed dominant and recessive inheritance with 50% penetrance. We took the higher of the two maximum LOD scores and subtracted 0.3 to correct for multiple tests (MMLS-C). We compared expected maximum LOD scores and power, using MMLS-C and NPL as well as the true model. Since NPL uses only the affected family members, we also performed an affecteds-only analysis using MMLS-C. The MMLS-C was both uniformly more powerful than NPL for most cases we examined, except when linkage information was low, and close to the results for the true model under locus heterogeneity. We still found better power for the MMLS-C compared with NPL in affecteds-only analysis. The results show that use of two simple modes of inheritance at a fixed penetrance can have more power than NPL when the trait mode of inheritance is complex and when there is heterogeneity in the data set.

  3. The Measurement of Maximal (Anaerobic) Power Output on a Cycle Ergometer: A Critical Review

    PubMed Central

    Driss, Tarak; Vandewalle, Henry

    2013-01-01

    The interests and limits of the different methods and protocols of maximal (anaerobic) power (P max) assessment are reviewed: single all-out tests versus force-velocity tests, isokinetic ergometers versus friction-loaded ergometers, measure of P max during the acceleration phase or at peak velocity. The effects of training, athletic practice, diet and pharmacological substances upon the production of maximal mechanical power are not discussed in this review mainly focused on the technical (ergometer, crank length, toe clips), methodological (protocols) and biological factors (muscle volume, muscle fiber type, age, gender, growth, temperature, chronobiology and fatigue) limiting P max in cycling. Although the validity of the Wingate test is questionable, a large part of the review is dedicated to this test which is currently the all-out cycling test the most often used. The biomechanical characteristics specific of maximal and high speed cycling, the bioenergetics of the all-out cycling exercises and the influence of biochemical factors (acidosis and alkalosis, phosphate ions…) are recalled at the beginning of the paper. The basic knowledge concerning the consequences of the force-velocity relationship upon power output, the biomechanics of sub-maximal cycling exercises and the study on the force-velocity relationship in cycling by Dickinson in 1928 are presented in Appendices. PMID:24073413

  4. An optimal tuning strategy for tidal turbines

    PubMed Central

    2016-01-01

    Tuning wind and tidal turbines is critical to maximizing their power output. Adopting a wind turbine tuning strategy of maximizing the output at any given time is shown to be an extremely poor strategy for large arrays of tidal turbines in channels. This ‘impatient-tuning strategy’ results in far lower power output, much higher structural loads and greater environmental impacts due to flow reduction than an existing ‘patient-tuning strategy’ which maximizes the power output averaged over the tidal cycle. This paper presents a ‘smart patient tuning strategy’, which can increase array output by up to 35% over the existing strategy. This smart strategy forgoes some power generation early in the half tidal cycle in order to allow stronger flows to develop later in the cycle. It extracts enough power from these stronger flows to produce more power from the cycle as a whole than the existing strategy. Surprisingly, the smart strategy can often extract more power without increasing maximum structural loads on the turbines, while also maintaining stronger flows along the channel. This paper also shows that, counterintuitively, for some tuning strategies imposing a cap on turbine power output to limit loads can increase a turbine’s average power output. PMID:27956870

  5. An optimal tuning strategy for tidal turbines

    NASA Astrophysics Data System (ADS)

    Vennell, Ross

    2016-11-01

    Tuning wind and tidal turbines is critical to maximizing their power output. Adopting a wind turbine tuning strategy of maximizing the output at any given time is shown to be an extremely poor strategy for large arrays of tidal turbines in channels. This `impatient-tuning strategy' results in far lower power output, much higher structural loads and greater environmental impacts due to flow reduction than an existing `patient-tuning strategy' which maximizes the power output averaged over the tidal cycle. This paper presents a `smart patient tuning strategy', which can increase array output by up to 35% over the existing strategy. This smart strategy forgoes some power generation early in the half tidal cycle in order to allow stronger flows to develop later in the cycle. It extracts enough power from these stronger flows to produce more power from the cycle as a whole than the existing strategy. Surprisingly, the smart strategy can often extract more power without increasing maximum structural loads on the turbines, while also maintaining stronger flows along the channel. This paper also shows that, counterintuitively, for some tuning strategies imposing a cap on turbine power output to limit loads can increase a turbine's average power output.

  6. An optimal tuning strategy for tidal turbines.

    PubMed

    Vennell, Ross

    2016-11-01

    Tuning wind and tidal turbines is critical to maximizing their power output. Adopting a wind turbine tuning strategy of maximizing the output at any given time is shown to be an extremely poor strategy for large arrays of tidal turbines in channels. This 'impatient-tuning strategy' results in far lower power output, much higher structural loads and greater environmental impacts due to flow reduction than an existing 'patient-tuning strategy' which maximizes the power output averaged over the tidal cycle. This paper presents a 'smart patient tuning strategy', which can increase array output by up to 35% over the existing strategy. This smart strategy forgoes some power generation early in the half tidal cycle in order to allow stronger flows to develop later in the cycle. It extracts enough power from these stronger flows to produce more power from the cycle as a whole than the existing strategy. Surprisingly, the smart strategy can often extract more power without increasing maximum structural loads on the turbines, while also maintaining stronger flows along the channel. This paper also shows that, counterintuitively, for some tuning strategies imposing a cap on turbine power output to limit loads can increase a turbine's average power output.

  7. Work extremum principle: structure and function of quantum heat engines.

    PubMed

    Allahverdyan, Armen E; Johal, Ramandeep S; Mahler, Guenter

    2008-04-01

    We consider a class of quantum heat engines consisting of two subsystems interacting with a work-source and coupled to two separate baths at different temperatures Th>Tc. The purpose of the engine is to extract work due to the temperature difference. Its dynamics is not restricted to the near equilibrium regime. The engine structure is determined by maximizing the extracted work under various constraints. When this maximization is carried out at finite power, the engine dynamics is described by well-defined temperatures and satisfies the local version of the second law. In addition, its efficiency is bounded from below by the Curzon-Ahlborn value 1-radical Tc/Th and from above by the Carnot value 1-(Tc/Th). The latter is reached-at finite power--for a macroscopic engine, while the former is achieved in the equilibrium limit Th-->Tc . The efficiency that maximizes the power is strictly larger than the Curzon-Ahloborn value. When the work is maximized at a zero power, even a small (few-level) engine extracts work right at the Carnot efficiency.

  8. Quantum coherence generating power, maximally abelian subalgebras, and Grassmannian geometry

    NASA Astrophysics Data System (ADS)

    Zanardi, Paolo; Campos Venuti, Lorenzo

    2018-01-01

    We establish a direct connection between the power of a unitary map in d-dimensions (d < ∞) to generate quantum coherence and the geometry of the set Md of maximally abelian subalgebras (of the quantum system full operator algebra). This set can be seen as a topologically non-trivial subset of the Grassmannian over linear operators. The natural distance over the Grassmannian induces a metric structure on Md, which quantifies the lack of commutativity between the pairs of subalgebras. Given a maximally abelian subalgebra, one can define, on physical grounds, an associated measure of quantum coherence. We show that the average quantum coherence generated by a unitary map acting on a uniform ensemble of quantum states in the algebra (the so-called coherence generating power of the map) is proportional to the distance between a pair of maximally abelian subalgebras in Md connected by the unitary transformation itself. By embedding the Grassmannian into a projective space, one can pull-back the standard Fubini-Study metric on Md and define in this way novel geometrical measures of quantum coherence generating power. We also briefly discuss the associated differential metric structures.

  9. Balancing Power Absorption and Structural Loading for a Novel Fixed-Bottom Wave Energy Converter with Nonideal Power Take-Off in Regular Waves: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tom, Nathan M; Yu, Yi-Hsiang; Wright, Alan D

    In this work, the net power delivered to the grid from a nonideal power take-off (PTO) is introduced followed by a review of the pseudo-spectral control theory. A power-to-load ratio, used to evaluate the pseudo-spectral controller performance, is discussed, and the results obtained from optimizing a multiterm objective function are compared against results obtained from maximizing the net output power to the grid. Simulation results are then presented for four different oscillating wave energy converter geometries to highlight the potential of combing both geometry and PTO control to maximize power while minimizing loads.

  10. The power to detect linkage in complex disease by means of simple LOD-score analyses.

    PubMed Central

    Greenberg, D A; Abreu, P; Hodge, S E

    1998-01-01

    Maximum-likelihood analysis (via LOD score) provides the most powerful method for finding linkage when the mode of inheritance (MOI) is known. However, because one must assume an MOI, the application of LOD-score analysis to complex disease has been questioned. Although it is known that one can legitimately maximize the maximum LOD score with respect to genetic parameters, this approach raises three concerns: (1) multiple testing, (2) effect on power to detect linkage, and (3) adequacy of the approximate MOI for the true MOI. We evaluated the power of LOD scores to detect linkage when the true MOI was complex but a LOD score analysis assumed simple models. We simulated data from 14 different genetic models, including dominant and recessive at high (80%) and low (20%) penetrances, intermediate models, and several additive two-locus models. We calculated LOD scores by assuming two simple models, dominant and recessive, each with 50% penetrance, then took the higher of the two LOD scores as the raw test statistic and corrected for multiple tests. We call this test statistic "MMLS-C." We found that the ELODs for MMLS-C are >=80% of the ELOD under the true model when the ELOD for the true model is >=3. Similarly, the power to reach a given LOD score was usually >=80% that of the true model, when the power under the true model was >=60%. These results underscore that a critical factor in LOD-score analysis is the MOI at the linked locus, not that of the disease or trait per se. Thus, a limited set of simple genetic models in LOD-score analysis can work well in testing for linkage. PMID:9718328

  11. The power to detect linkage in complex disease by means of simple LOD-score analyses.

    PubMed

    Greenberg, D A; Abreu, P; Hodge, S E

    1998-09-01

    Maximum-likelihood analysis (via LOD score) provides the most powerful method for finding linkage when the mode of inheritance (MOI) is known. However, because one must assume an MOI, the application of LOD-score analysis to complex disease has been questioned. Although it is known that one can legitimately maximize the maximum LOD score with respect to genetic parameters, this approach raises three concerns: (1) multiple testing, (2) effect on power to detect linkage, and (3) adequacy of the approximate MOI for the true MOI. We evaluated the power of LOD scores to detect linkage when the true MOI was complex but a LOD score analysis assumed simple models. We simulated data from 14 different genetic models, including dominant and recessive at high (80%) and low (20%) penetrances, intermediate models, and several additive two-locus models. We calculated LOD scores by assuming two simple models, dominant and recessive, each with 50% penetrance, then took the higher of the two LOD scores as the raw test statistic and corrected for multiple tests. We call this test statistic "MMLS-C." We found that the ELODs for MMLS-C are >=80% of the ELOD under the true model when the ELOD for the true model is >=3. Similarly, the power to reach a given LOD score was usually >=80% that of the true model, when the power under the true model was >=60%. These results underscore that a critical factor in LOD-score analysis is the MOI at the linked locus, not that of the disease or trait per se. Thus, a limited set of simple genetic models in LOD-score analysis can work well in testing for linkage.

  12. TATES: Efficient Multivariate Genotype-Phenotype Analysis for Genome-Wide Association Studies

    PubMed Central

    van der Sluis, Sophie; Posthuma, Danielle; Dolan, Conor V.

    2013-01-01

    To date, the genome-wide association study (GWAS) is the primary tool to identify genetic variants that cause phenotypic variation. As GWAS analyses are generally univariate in nature, multivariate phenotypic information is usually reduced to a single composite score. This practice often results in loss of statistical power to detect causal variants. Multivariate genotype–phenotype methods do exist but attain maximal power only in special circumstances. Here, we present a new multivariate method that we refer to as TATES (Trait-based Association Test that uses Extended Simes procedure), inspired by the GATES procedure proposed by Li et al (2011). For each component of a multivariate trait, TATES combines p-values obtained in standard univariate GWAS to acquire one trait-based p-value, while correcting for correlations between components. Extensive simulations, probing a wide variety of genotype–phenotype models, show that TATES's false positive rate is correct, and that TATES's statistical power to detect causal variants explaining 0.5% of the variance can be 2.5–9 times higher than the power of univariate tests based on composite scores and 1.5–2 times higher than the power of the standard MANOVA. Unlike other multivariate methods, TATES detects both genetic variants that are common to multiple phenotypes and genetic variants that are specific to a single phenotype, i.e. TATES provides a more complete view of the genetic architecture of complex traits. As the actual causal genotype–phenotype model is usually unknown and probably phenotypically and genetically complex, TATES, available as an open source program, constitutes a powerful new multivariate strategy that allows researchers to identify novel causal variants, while the complexity of traits is no longer a limiting factor. PMID:23359524

  13. Statistical mechanics of influence maximization with thermal noise

    NASA Astrophysics Data System (ADS)

    Lynn, Christopher W.; Lee, Daniel D.

    2017-03-01

    The problem of optimally distributing a budget of influence among individuals in a social network, known as influence maximization, has typically been studied in the context of contagion models and deterministic processes, which fail to capture stochastic interactions inherent in real-world settings. Here, we show that by introducing thermal noise into influence models, the dynamics exactly resemble spins in a heterogeneous Ising system. In this way, influence maximization in the presence of thermal noise has a natural physical interpretation as maximizing the magnetization of an Ising system given a budget of external magnetic field. Using this statistical mechanical formulation, we demonstrate analytically that for small external-field budgets, the optimal influence solutions exhibit a highly non-trivial temperature dependence, focusing on high-degree hub nodes at high temperatures and on easily influenced peripheral nodes at low temperatures. For the general problem, we present a projected gradient ascent algorithm that uses the magnetic susceptibility to calculate locally optimal external-field distributions. We apply our algorithm to synthetic and real-world networks, demonstrating that our analytic results generalize qualitatively. Our work establishes a fruitful connection with statistical mechanics and demonstrates that influence maximization depends crucially on the temperature of the system, a fact that has not been appreciated by existing research.

  14. An omnibus test for the global null hypothesis.

    PubMed

    Futschik, Andreas; Taus, Thomas; Zehetmayer, Sonja

    2018-01-01

    Global hypothesis tests are a useful tool in the context of clinical trials, genetic studies, or meta-analyses, when researchers are not interested in testing individual hypotheses, but in testing whether none of the hypotheses is false. There are several possibilities how to test the global null hypothesis when the individual null hypotheses are independent. If it is assumed that many of the individual null hypotheses are false, combination tests have been recommended to maximize power. If, however, it is assumed that only one or a few null hypotheses are false, global tests based on individual test statistics are more powerful (e.g. Bonferroni or Simes test). However, usually there is no a priori knowledge on the number of false individual null hypotheses. We therefore propose an omnibus test based on cumulative sums of the transformed p-values. We show that this test yields an impressive overall performance. The proposed method is implemented in an R-package called omnibus.

  15. Current fluctuations in quantum absorption refrigerators

    NASA Astrophysics Data System (ADS)

    Segal, Dvira

    2018-05-01

    Absorption refrigerators transfer thermal energy from a cold bath to a hot bath without input power by utilizing heat from an additional "work" reservoir. Particularly interesting is a three-level design for a quantum absorption refrigerator, which can be optimized to reach the maximal (Carnot) cooling efficiency. Previous studies of three-level chillers focused on the behavior of the averaged cooling current. Here, we go beyond that and study the full counting statistics of heat exchange in a three-level chiller model. We explain how to obtain the complete cumulant generating function of the refrigerator in a steady state, then derive a partial cumulant generating function, which yields closed-form expressions for both the averaged cooling current and its noise. Our analytical results and simulations are beneficial for the design of nanoscale engines and cooling systems far from equilibrium, with their performance optimized according to different criteria, efficiency, power, fluctuations, and dissipation.

  16. Effect of ageing on hypoxic exercise cardiorespiratory, muscle and cerebral oxygenation responses in healthy humans.

    PubMed

    Puthon, Lara; Bouzat, Pierre; Robach, Paul; Favre-Juvin, Anne; Doutreleau, Stéphane; Verges, Samuel

    2017-04-01

    What is the central question of this study? This study aimed to determine the effect of ageing on cardiorespiratory and tissue oxygenation responses to hypoxia during maximal incremental exercise. What is the main finding and its importance? Older healthy subjects had preserved hypoxic cardiorespiratory and tissue oxygenation responses at rest and during moderate exercise. At maximal exercise, they had a reduced hypoxic ventilatory response but similar maximal power output reduction compared with young individuals. This study suggests that until moderate exercise, hypoxic responses are preserved until the age of 70 years and therefore that ageing is not a contraindication for high-altitude sojourn. This study assessed the effects of ageing on cardiorespiratory and tissue oxygenation responses to hypoxia both at rest and during incremental maximal exercise. Sixteen young (20-30 years old) and 15 older healthy subjects (60-70 years old) performed two maximal incremental cycling tests in normoxia and hypoxia (inspiratory oxygen fraction 12%). Cardiorespiratory responses, prefrontal cortex and quadriceps tissue oxygenation (near-infrared spectroscopy) were measured during exercise as well as during hypercapnia at rest. The hypoxic ventilatory response was similar in young compared with older individuals at rest and during moderate-intensity exercise (50% maximal power output: young 0.9 ± 0.2 versus older 1.1 ± 0.8 l min -1  % -1 ; P > 0.05) but larger in young subjects during high-intensity exercise (maximal power output: 2.2 ± 0.8 versus 1.8 ± 1.1 l min -1  % -1 ; P < 0.05). The hypoxic cardiac response did not differ between groups both at rest and during exercise. During exercise in hypoxia, young subjects showed greater deoxygenation than older subjects, at both the prefrontal cortex and quadriceps levels. The hypoxia-induced reduction in maximal power output (young -32 ± 5% versus older -30 ± 6%; P > 0.05) and the hypercapnic responses did not differ between groups. Older healthy and active individuals below the age of 70 years have cardiorespiratory and tissue oxygenation responses to hypoxia similar to young individuals both at rest and during moderate-intensity exercise. Despite a lower hypoxic ventilatory response at maximal exercise, older individuals have similar oxygen desaturation and maximal power output reduction compared with young subjects. © 2017 The Authors. Experimental Physiology © 2017 The Physiological Society.

  17. Comparison of In-Season-Specific Resistance vs. A Regular Throwing Training Program on Throwing Velocity, Anthropometry, and Power Performance in Elite Handball Players.

    PubMed

    Hermassi, Souhail; van den Tillaar, Roland; Khlifa, Riadh; Chelly, Mohamed Souhaiel; Chamari, Karim

    2015-08-01

    The purpose of this study was to compare the effect of a specific resistance training program (throwing movement with a medicine ball) with that of regular training (throwing with regular balls) on ball velocity, anthropometry, maximal upper-body strength, and power. Thirty-four elite male team handball players (age: 18 ± 0.5 years, body mass: 80.6 ± 5.5 kg, height: 1.80 ± 5.1 m, body fat: 13.4 ± 0.6%) were randomly assigned to 1 of the 3 groups: control (n = 10), resistance training group (n = 12), or regular throwing training group (n = 12). Over the 8-week in season, the athletes performed 3 times per week according to an assigned training program alongside their normal team handball training. One repetition maximum (1RM) bench press and 1RM pullover scores assessed maximal arm strength. Anthropometry was assessed by body mass, fat percentage, and muscle volumes of upper body. Handball throwing velocity was measured by a standing throw, a throw with run, and a jump throw. Power was measured by measuring total distance thrown by a 3-kg medicine ball overhead throw. Throwing ball velocity, maximal strength, power, and muscle volume increases for the specific resistance training group after the 8 weeks of training, whereas only maximal strength, muscle volume and power and in the jump throw increases were found for the regular throwing training group. No significant changes for the control group were found. The current findings suggest that elite male handball players can improve ball velocity, anthropometrics, maximal upper-body strength, and power during the competition season by implementing a medicine ball throwing program.

  18. Active Female Maximal and Anaerobic Threshold Cardiorespiratory Responses to Six Different Water Aerobics Exercises.

    PubMed

    Antunes, Amanda H; Alberton, Cristine L; Finatto, Paula; Pinto, Stephanie S; Cadore, Eduardo L; Zaffari, Paula; Kruel, Luiz F M

    2015-01-01

    Maximal tests conducted on land are not suitable for the prescription of aquatic exercises, which makes it difficult to optimize the intensity of water aerobics classes. The aim of the present study was to evaluate the maximal and anaerobic threshold cardiorespiratory responses to 6 water aerobics exercises. Volunteers performed 3 of the exercises in the sagittal plane and 3 in the frontal plane. Twelve active female volunteers (aged 24 ± 2 years) performed 6 maximal progressive test sessions. Throughout the exercise tests, we measured heart rate (HR) and oxygen consumption (VO2). We randomized all sessions with a minimum interval of 48 hr between each session. For statistical analysis, we used repeated-measures 1-way analysis of variance. Regarding the maximal responses, for the peak VO2, abductor hop and jumping jacks (JJ) showed significantly lower values than frontal kick and cross-country skiing (CCS; p < .001; partial η(2) = .509), while for the peak HR, JJ showed statistically significantly lower responses compared with stationary running and CCS (p < .001; partial η(2) = .401). At anaerobic threshold intensity expressed as the percentage of the maximum values, no statistically significant differences were found among exercises. Cardiorespiratory responses are directly associated with the muscle mass involved in the exercise. Thus, it is worth emphasizing the importance of performing a maximal test that is specific to the analyzed exercise so the prescription of the intensity can be safer and valid.

  19. Control Strategies for Distributed Energy Resources to Maximize the Use of Wind Power in Rural Microgrids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, Shuai; Elizondo, Marcelo A.; Samaan, Nader A.

    2011-10-10

    The focus of this paper is to design control strategies for distributed energy resources (DERs) to maximize the use of wind power in a rural microgrid. In such a system, it may be economical to harness wind power to reduce the consumption of fossil fuels for electricity production. In this work, we develop control strategies for DERs, including diesel generators, energy storage and demand response, to achieve high penetration of wind energy in a rural microgrid. Combinations of centralized (direct control) and decentralized (autonomous response) control strategies are investigated. Detailed dynamic models for a rural microgrid are built to conductmore » simulations. The system response to large disturbances and frequency regulation are tested. It is shown that optimal control coordination of DERs can be achieved to maintain system frequency while maximizing wind power usage and reducing the wear and tear on fossil fueled generators.« less

  20. On Market-Based Coordination of Thermostatically Controlled Loads With User Preference

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Sen; Zhang, Wei; Lian, Jianming

    2014-12-15

    This paper presents a market-based control framework to coordinate a group of autonomous Thermostatically Controlled Loads (TCL) to achieve the system-level objectives with pricing incentives. The problem is formulated as maximizing the social welfare subject to feeder power constraint. It allows the coordinator to affect the aggregated power of a group of dynamical systems, and creates an interactive market where the users and the coordinator cooperatively determine the optimal energy allocation and energy price. The optimal pricing strategy is derived, which maximizes social welfare while respecting the feeder power constraint. The bidding strategy is also designed to compute the optimalmore » price in real time (e.g., every 5 minutes) based on local device information. The coordination framework is validated with realistic simulations in GridLab-D. Extensive simulation results demonstrate that the proposed approach effectively maximizes the social welfare and decreases power congestion at key times.« less

  1. Improved minimum cost and maximum power two stage genome-wide association study designs.

    PubMed

    Stanhope, Stephen A; Skol, Andrew D

    2012-01-01

    In a two stage genome-wide association study (2S-GWAS), a sample of cases and controls is allocated into two groups, and genetic markers are analyzed sequentially with respect to these groups. For such studies, experimental design considerations have primarily focused on minimizing study cost as a function of the allocation of cases and controls to stages, subject to a constraint on the power to detect an associated marker. However, most treatments of this problem implicitly restrict the set of feasible designs to only those that allocate the same proportions of cases and controls to each stage. In this paper, we demonstrate that removing this restriction can improve the cost advantages demonstrated by previous 2S-GWAS designs by up to 40%. Additionally, we consider designs that maximize study power with respect to a cost constraint, and show that recalculated power maximizing designs can recover a substantial amount of the planned study power that might otherwise be lost if study funding is reduced. We provide open source software for calculating cost minimizing or power maximizing 2S-GWAS designs.

  2. Optimal Energy Management for a Smart Grid using Resource-Aware Utility Maximization

    NASA Astrophysics Data System (ADS)

    Abegaz, Brook W.; Mahajan, Satish M.; Negeri, Ebisa O.

    2016-06-01

    Heterogeneous energy prosumers are aggregated to form a smart grid based energy community managed by a central controller which could maximize their collective energy resource utilization. Using the central controller and distributed energy management systems, various mechanisms that harness the power profile of the energy community are developed for optimal, multi-objective energy management. The proposed mechanisms include resource-aware, multi-variable energy utility maximization objectives, namely: (1) maximizing the net green energy utilization, (2) maximizing the prosumers' level of comfortable, high quality power usage, and (3) maximizing the economic dispatch of energy storage units that minimize the net energy cost of the energy community. Moreover, an optimal energy management solution that combines the three objectives has been implemented by developing novel techniques of optimally flexible (un)certainty projection and appliance based pricing decomposition in an IBM ILOG CPLEX studio. A real-world, per-minute data from an energy community consisting of forty prosumers in Amsterdam, Netherlands is used. Results show that each of the proposed mechanisms yields significant increases in the aggregate energy resource utilization and welfare of prosumers as compared to traditional peak-power reduction methods. Furthermore, the multi-objective, resource-aware utility maximization approach leads to an optimal energy equilibrium and provides a sustainable energy management solution as verified by the Lagrangian method. The proposed resource-aware mechanisms could directly benefit emerging energy communities in the world to attain their energy resource utilization targets.

  3. Power and impulse applied during push press exercise.

    PubMed

    Lake, Jason P; Mundy, Peter D; Comfort, Paul

    2014-09-01

    The aim of this study was to quantify the load, which maximized peak and mean power, and impulse applied to these loads, during the push press and to compare them to equivalent jump squat data. Resistance-trained men performed 2 push press (n = 17; age: 25.4 ± 7.4 years; height: 183.4 ± 5 cm; body mass: 87 ± 15.6 kg) and jump squat (n = 8 of original 17; age: 28.7 ± 8.1 years; height: 184.3 ± 5.5 cm; mass: 98 ± 5.3 kg) singles with 10-90% of their push press and back squat 1 repetition maximum (1RM), respectively, in 10% 1RM increments while standing on a force platform. Push press peak and mean power was maximized with 75.3 ± 16.4 and 64.7 ± 20% 1RM, respectively, and impulses applied to these loads were 243 ± 29 N·s and 231 ± 36 N·s. Increasing and decreasing load, from the load that maximized peak and mean power, by 10 and 20% 1RM reduced peak and mean power by 6-15% (p ≤ 0.05). Push press and jump squat maximum peak power (7%, p = 0.08) and the impulse that was applied to the load that maximized peak (8%, p = 0.17) and mean (13%, p = 0.91) power were not significantly different, but push press maximum mean power was significantly greater than the jump squat equivalent (∼9.5%, p = 0.03). The mechanical demand of the push press is comparable with the jump squat and could provide a time-efficient combination of lower-body power and upper-body and trunk strength training.

  4. Inter-relationships between machine squat-jump strength, force, power and 10 m sprint times in trained sportsmen.

    PubMed

    Harris, Nigel K; Cronin, J B; Hopkins, W G; Hansen, K T

    2010-03-01

    Strength and conditioning practitioners appear focussed on developing maximal strength based on the premise that it underpins explosive muscular performance. Investigation into the relationship between strength and a multitude of explosive power measures is limited though. Furthermore, the relationship of explosive force and power with functional performance is unclear. We examined the inter-relationships between maximal strength and explosive measures of force and power at different loads. Also investigated were the relationships between explosive measures and 10-m sprinting ability. Forty elite-level well-trained rugby union and league athletes performed 10-m sprints followed by bilateral concentric-only machine squat-jumps at 20 and 80%1RM. The magnitudes of the inter-relationships between groups of force measures, power measures and sprint times were interpreted using Pearson correlation coefficients, which had uncertainty (90% confidence limits) of approximately +/-0.25. Measures investigated included peak force, peak power, rate of force development, and some of Zatsiorsky's explosive measures, all expressed relative to body mass. The relationship between maximal strength and peak power was moderate at 20 %1RM (r=0.32) but trivial at 80 %1RM (r=-0.03). Practically no relationship between any of the explosive measures and 10-m sprint ability was observed (r=-0.01 to 0.06). Although correlations do not imply cause and effect, we speculate that the common practice of focussing on high levels of maximal strength in a machine squat to improve power output may be misguided. Our results also cast doubt on the efficacy of increasing explosive force and power in a machine squat-jump with the intention of improving sprint ability in well-trained athletes.

  5. A descriptive comparison of sprint cycling performance and neuromuscular characteristics in able-bodied athletes and paralympic athletes with cerebral palsy.

    PubMed

    Runciman, Phoebe; Derman, Wayne; Ferreira, Suzanne; Albertus-Kajee, Yumna; Tucker, Ross

    2015-01-01

    This study investigated the sprint cycling performance and neuromuscular characteristics of Paralympic athletes with cerebral palsy (CP) during a fatiguing maximal cycling trial compared with those of able-bodied (AB) athletes. Five elite athletes with CP and 16 AB age- and performance-matched controls performed a 30-sec Wingate cycle test. Power output (W/kg) and fatigue index (%) were calculated. Electromyography was measured in five bilateral muscles and expressed in mean amplitude (mV) and median frequency (Hz). Power output was significantly higher in the AB group (10.4 [0.5] W/kg) than in the CP group (9.8 [0.5] W/kg) (P < 0.05). Fatigue index was statistically similar between the AB (27% [0.1%]) and CP (25% [0.1%]) groups. Electromyographic mean amplitude and frequency changed similarly in all muscle groups tested, in both affected and nonaffected sides, in the CP and AB groups (P < 0.05). Neuromuscular irregularities were identified in the CP group. The similarity in fatigue between the CP and AB groups indicates that elite athletes with CP may have a different exercise response to others with CP. The authors propose that this may result from high-level training over many years. This has rehabilitative implications, as it indicates near-maximal adaptation of the CP body toward normal levels.

  6. Rigorous theory of graded thermoelectric converters including finite heat transfer coefficients

    NASA Astrophysics Data System (ADS)

    Gerstenmaier, York Christian; Wachutka, Gerhard

    2017-11-01

    Maximization of thermoelectric (TE) converter performance with an inhomogeneous material and electric current distribution has been investigated in previous literature neglecting thermal contact resistances to the heat reservoirs. The heat transfer coefficients (HTCs), defined as inverse thermal contact resistances per unit area, are thus infinite, whereas in reality, always parasitic thermal resistances, i.e., finite HTCs, are present. Maximization of the generated electric power and of cooling power in the refrigerator mode with respect to Seebeck coefficients and heat conductivity for a given profile of the material's TE figure of merit Z are mathematically ill-posed problems in the presence of infinite HTCs. As will be shown in this work, a fully self consistent solution is possible for finite HTCs, and in many respects, the results are fundamentally different. A previous theory for 3D devices will be extended to include finite HTCs and is applied to 1D devices. For the heat conductivity profile, an infinite number of solutions exist leading to the same device performance. Cooling power maximization for finite HTCs in 1D will lead to a strongly enhanced corresponding efficiency (coefficient of performance), whereas results with infinite HTCs lead to a non-monotonous temperature profile and coefficient of performance tending to zero for the prescribed heat conductivities. For maximized generated electric power, the corresponding generator efficiency is nearly a constant independent from the finite HTC values. The maximized efficiencies in the generator and cooling mode are equal to the efficiencies for the infinite HTC, provided that the corresponding powers approach zero. These and more findings are condensed in 4 theorems in the conclusions.

  7. Early effects of ageing on the mechanical performance of isolated locomotory (EDL) and respiratory (diaphragm) skeletal muscle using the work-loop technique.

    PubMed

    Tallis, Jason; James, Rob S; Little, Alexander G; Cox, Val M; Duncan, Michael J; Seebacher, Frank

    2014-09-15

    Previous isolated muscle studies examining the effects of ageing on contractility have used isometric protocols, which have been shown to have poor relevance to dynamic muscle performance in vivo. The present study uniquely uses the work-loop technique for a more realistic estimation of in vivo muscle function to examine changes in mammalian skeletal muscle mechanical properties with age. Measurements of maximal isometric stress, activation and relaxation time, maximal power output, and sustained power output during repetitive activation and recovery are compared in locomotory extensor digitorum longus (EDL) and core diaphragm muscle isolated from 3-, 10-, 30-, and 50-wk-old female mice to examine the early onset of ageing. A progressive age-related reduction in maximal isometric stress that was of greater magnitude than the decrease in maximal power output occurred in both muscles. Maximal force and power developed earlier in diaphragm than EDL muscle but demonstrated a greater age-related decline. The present study indicates that ability to sustain skeletal muscle power output through repetitive contraction is age- and muscle-dependent, which may help rationalize previously reported equivocal results from examination of the effect of age on muscular endurance. The age-related decline in EDL muscle performance is prevalent without a significant reduction in muscle mass, and biochemical analysis of key marker enzymes suggests that although there is some evidence of a more oxidative fiber type, this is not the primary contributor to the early age-related reduction in muscle contractility. Copyright © 2014 the American Physiological Society.

  8. Skeletal muscle power and fatigue at the tolerable limit of ramp-incremental exercise in COPD.

    PubMed

    Cannon, Daniel T; Coelho, Ana Claudia; Cao, Robert; Cheng, Andrew; Porszasz, Janos; Casaburi, Richard; Rossiter, Harry B

    2016-12-01

    Muscle fatigue (a reduced power for a given activation) is common following exercise in chronic obstructive pulmonary disease (COPD). Whether muscle fatigue, and reduced maximal voluntary locomotor power, are sufficient to limit whole body exercise in COPD is unknown. We hypothesized in COPD: 1) exercise is terminated with a locomotor muscle power reserve; 2) reduction in maximal locomotor power is related to ventilatory limitation; and 3) muscle fatigue at intolerance is less than age-matched controls. We used a rapid switch from hyperbolic to isokinetic cycling to measure the decline in peak isokinetic power at the limit of incremental exercise ("performance fatigue") in 13 COPD patients (FEV 1 49 ± 17%pred) and 12 controls. By establishing the baseline relationship between muscle activity and isokinetic power, we apportioned performance fatigue into the reduction in muscle activation and muscle fatigue. Peak isokinetic power at intolerance was ~130% of peak incremental power in controls (274 ± 73 vs. 212 ± 84 W, P < 0.05), but ~260% in COPD patients (187 ± 141 vs. 72 ± 34 W, P < 0.05), greater than controls (P < 0.05). Muscle fatigue as a fraction of baseline peak isokinetic power was not different in COPD patients vs. controls (0.11 ± 0.20 vs. 0.19 ± 0.11). Baseline to intolerance, the median frequency of maximal isokinetic muscle activity, was unchanged in COPD patients but reduced in controls (+4.3 ± 11.6 vs. -5.5 ± 7.6%, P < 0.05). Performance fatigue as a fraction of peak incremental power was greater in COPD vs. controls and related to resting (FEV 1 /FVC) and peak exercise (V̇ E /maximal voluntary ventilation) pulmonary function (r 2 = 0.47 and 0.55, P < 0.05). COPD patients are more fatigable than controls, but this fatigue is insufficient to constrain locomotor power and define exercise intolerance. Copyright © 2016 the American Physiological Society.

  9. Stochastic Short-term High-resolution Prediction of Solar Irradiance and Photovoltaic Power Output

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Melin, Alexander M.; Olama, Mohammed M.; Dong, Jin

    The increased penetration of solar photovoltaic (PV) energy sources into electric grids has increased the need for accurate modeling and prediction of solar irradiance and power production. Existing modeling and prediction techniques focus on long-term low-resolution prediction over minutes to years. This paper examines the stochastic modeling and short-term high-resolution prediction of solar irradiance and PV power output. We propose a stochastic state-space model to characterize the behaviors of solar irradiance and PV power output. This prediction model is suitable for the development of optimal power controllers for PV sources. A filter-based expectation-maximization and Kalman filtering mechanism is employed tomore » estimate the parameters and states in the state-space model. The mechanism results in a finite dimensional filter which only uses the first and second order statistics. The structure of the scheme contributes to a direct prediction of the solar irradiance and PV power output without any linearization process or simplifying assumptions of the signal’s model. This enables the system to accurately predict small as well as large fluctuations of the solar signals. The mechanism is recursive allowing the solar irradiance and PV power to be predicted online from measurements. The mechanism is tested using solar irradiance and PV power measurement data collected locally in our lab.« less

  10. Adaptive Sampling of Time Series During Remote Exploration

    NASA Technical Reports Server (NTRS)

    Thompson, David R.

    2012-01-01

    This work deals with the challenge of online adaptive data collection in a time series. A remote sensor or explorer agent adapts its rate of data collection in order to track anomalous events while obeying constraints on time and power. This problem is challenging because the agent has limited visibility (all its datapoints lie in the past) and limited control (it can only decide when to collect its next datapoint). This problem is treated from an information-theoretic perspective, fitting a probabilistic model to collected data and optimizing the future sampling strategy to maximize information gain. The performance characteristics of stationary and nonstationary Gaussian process models are compared. Self-throttling sensors could benefit environmental sensor networks and monitoring as well as robotic exploration. Explorer agents can improve performance by adjusting their data collection rate, preserving scarce power or bandwidth resources during uninteresting times while fully covering anomalous events of interest. For example, a remote earthquake sensor could conserve power by limiting its measurements during normal conditions and increasing its cadence during rare earthquake events. A similar capability could improve sensor platforms traversing a fixed trajectory, such as an exploration rover transect or a deep space flyby. These agents can adapt observation times to improve sample coverage during moments of rapid change. An adaptive sampling approach couples sensor autonomy, instrument interpretation, and sampling. The challenge is addressed as an active learning problem, which already has extensive theoretical treatment in the statistics and machine learning literature. A statistical Gaussian process (GP) model is employed to guide sample decisions that maximize information gain. Nonsta tion - ary (e.g., time-varying) covariance relationships permit the system to represent and track local anomalies, in contrast with current GP approaches. Most common GP models are stationary, e.g., the covariance relationships are time-invariant. In such cases, information gain is independent of previously collected data, and the optimal solution can always be computed in advance. Information-optimal sampling of a stationary GP time series thus reduces to even spacing, and such models are not appropriate for tracking localized anomalies. Additionally, GP model inference can be computationally expensive.

  11. A Low-Cost Method for Multiple Disease Prediction.

    PubMed

    Bayati, Mohsen; Bhaskar, Sonia; Montanari, Andrea

    Recently, in response to the rising costs of healthcare services, employers that are financially responsible for the healthcare costs of their workforce have been investing in health improvement programs for their employees. A main objective of these so called "wellness programs" is to reduce the incidence of chronic illnesses such as cardiovascular disease, cancer, diabetes, and obesity, with the goal of reducing future medical costs. The majority of these wellness programs include an annual screening to detect individuals with the highest risk of developing chronic disease. Once these individuals are identified, the company can invest in interventions to reduce the risk of those individuals. However, capturing many biomarkers per employee creates a costly screening procedure. We propose a statistical data-driven method to address this challenge by minimizing the number of biomarkers in the screening procedure while maximizing the predictive power over a broad spectrum of diseases. Our solution uses multi-task learning and group dimensionality reduction from machine learning and statistics. We provide empirical validation of the proposed solution using data from two different electronic medical records systems, with comparisons to a statistical benchmark.

  12. Complex systems analysis of series of blackouts: cascading failure, critical points, and self-organization.

    PubMed

    Dobson, Ian; Carreras, Benjamin A; Lynch, Vickie E; Newman, David E

    2007-06-01

    We give an overview of a complex systems approach to large blackouts of electric power transmission systems caused by cascading failure. Instead of looking at the details of particular blackouts, we study the statistics and dynamics of series of blackouts with approximate global models. Blackout data from several countries suggest that the frequency of large blackouts is governed by a power law. The power law makes the risk of large blackouts consequential and is consistent with the power system being a complex system designed and operated near a critical point. Power system overall loading or stress relative to operating limits is a key factor affecting the risk of cascading failure. Power system blackout models and abstract models of cascading failure show critical points with power law behavior as load is increased. To explain why the power system is operated near these critical points and inspired by concepts from self-organized criticality, we suggest that power system operating margins evolve slowly to near a critical point and confirm this idea using a power system model. The slow evolution of the power system is driven by a steady increase in electric loading, economic pressures to maximize the use of the grid, and the engineering responses to blackouts that upgrade the system. Mitigation of blackout risk should account for dynamical effects in complex self-organized critical systems. For example, some methods of suppressing small blackouts could ultimately increase the risk of large blackouts.

  13. The Universal Statistical Distributions of the Affinity, Equilibrium Constants, Kinetics and Specificity in Biomolecular Recognition

    PubMed Central

    Zheng, Xiliang; Wang, Jin

    2015-01-01

    We uncovered the universal statistical laws for the biomolecular recognition/binding process. We quantified the statistical energy landscapes for binding, from which we can characterize the distributions of the binding free energy (affinity), the equilibrium constants, the kinetics and the specificity by exploring the different ligands binding with a particular receptor. The results of the analytical studies are confirmed by the microscopic flexible docking simulations. The distribution of binding affinity is Gaussian around the mean and becomes exponential near the tail. The equilibrium constants of the binding follow a log-normal distribution around the mean and a power law distribution in the tail. The intrinsic specificity for biomolecular recognition measures the degree of discrimination of native versus non-native binding and the optimization of which becomes the maximization of the ratio of the free energy gap between the native state and the average of non-native states versus the roughness measured by the variance of the free energy landscape around its mean. The intrinsic specificity obeys a Gaussian distribution near the mean and an exponential distribution near the tail. Furthermore, the kinetics of binding follows a log-normal distribution near the mean and a power law distribution at the tail. Our study provides new insights into the statistical nature of thermodynamics, kinetics and function from different ligands binding with a specific receptor or equivalently specific ligand binding with different receptors. The elucidation of distributions of the kinetics and free energy has guiding roles in studying biomolecular recognition and function through small-molecule evolution and chemical genetics. PMID:25885453

  14. Effect of Repeated Whole Blood Donations on Aerobic Capacity and Hemoglobin Mass in Moderately Trained Male Subjects: A Randomized Controlled Trial.

    PubMed

    Meurrens, Julie; Steiner, Thomas; Ponette, Jonathan; Janssen, Hans Antonius; Ramaekers, Monique; Wehrlin, Jon Peter; Vandekerckhove, Philippe; Deldicque, Louise

    2016-12-01

    The aims of the present study were to investigate the impact of three whole blood donations on endurance capacity and hematological parameters and to determine the duration to fully recover initial endurance capacity and hematological parameters after each donation. Twenty-four moderately trained subjects were randomly divided in a donation (n = 16) and a placebo (n = 8) group. Each of the three donations was interspersed by 3 months, and the recovery of endurance capacity and hematological parameters was monitored up to 1 month after donation. Maximal power output, peak oxygen consumption, and hemoglobin mass decreased (p < 0.001) up to 4 weeks after a single blood donation with a maximal decrease of 4, 10, and 7%, respectively. Hematocrit, hemoglobin concentration, ferritin, and red blood cell count (RBC), all key hematological parameters for oxygen transport, were lowered by a single donation (p < 0.001) and cumulatively further affected by the repetition of the donations (p < 0.001). The maximal decrease after a blood donation was 11% for hematocrit, 10% for hemoglobin concentration, 50% for ferritin, and 12% for RBC (p < 0.001). Maximal power output cumulatively increased in the placebo group as the maximal exercise tests were repeated (p < 0.001), which indicates positive training adaptations. This increase in maximal power output over the whole duration of the study was not observed in the donation group. Maximal, but not submaximal, endurance capacity was altered after blood donation in moderately trained people and the expected increase in capacity after multiple maximal exercise tests was not present when repeating whole blood donations.

  15. Controlling bias and inflation in epigenome- and transcriptome-wide association studies using the empirical null distribution.

    PubMed

    van Iterson, Maarten; van Zwet, Erik W; Heijmans, Bastiaan T

    2017-01-27

    We show that epigenome- and transcriptome-wide association studies (EWAS and TWAS) are prone to significant inflation and bias of test statistics, an unrecognized phenomenon introducing spurious findings if left unaddressed. Neither GWAS-based methodology nor state-of-the-art confounder adjustment methods completely remove bias and inflation. We propose a Bayesian method to control bias and inflation in EWAS and TWAS based on estimation of the empirical null distribution. Using simulations and real data, we demonstrate that our method maximizes power while properly controlling the false positive rate. We illustrate the utility of our method in large-scale EWAS and TWAS meta-analyses of age and smoking.

  16. Effects of in-competitive season power-oriented and heavy resistance lower-body training on performance of elite female water polo players.

    PubMed

    Veliz, Rafael R; Suarez-Arrones, Luis; Requena, Bernardo; Haff, G Gregory; Feito, Javier; Sáez de Villarreal, Eduardo

    2015-02-01

    We examined the effect of 16 weeks of lower-body resistance and power-oriented training on key performance measures of elite female water polo players. Twenty-one players were randomly assigned to 2 groups: control group (C) who did in-water training only and a lower body strength (LBS) group, who performed resistance (full squat and split squat) and jump and power-oriented lower-body training (countermovement jump [CMJ] loaded and CMJ) sessions (twice per week) in addition to the same in-water training. In-water training was conducted 5 days per week for a total of 16 weeks. Twenty-meter maximal sprint swim (MSS), lower-body strength during 1 repetition maximum (1RM) full squat (FS), in-water boost and CMJ, and Throwing speed (ThS) were measured before and after the training. Pretraining results showed no statistically significant differences between the groups in any of the variables tested. After 16 weeks, no statistically significant improvement was found in any of the variables measured in the C group, however, significant improvement was found in the LBS group: in-water boost (4.6 cm, 12.02%, effect size [ES] = 1.02), CMJ (2.4 cm, 8.66%, ES = 0.85), FS (12.7 kg, 20.99%, ES = 2.41), and ThS (3.4 km·h, 6.86%, ES = 3.44). Lower-body resistance and power-oriented training in female water polo players for 16 weeks produced significant improvements in performance qualities highly specific to water polo performance. Therefore, we propose modifications to current training methodology for female water polo players to include resistance and power-oriented training during the competitive season in this sport.

  17. Power enhancement of heat engines via correlated thermalization in a three-level "working fluid".

    PubMed

    Gelbwaser-Klimovsky, David; Niedenzu, Wolfgang; Brumer, Paul; Kurizki, Gershon

    2015-09-23

    We explore means of maximizing the power output of a heat engine based on a periodically-driven quantum system that is constantly coupled to hot and cold baths. It is shown that the maximal power output of such a heat engine whose "working fluid" is a degenerate V-type three-level system is that generated by two independent two-level systems. Hence, level degeneracy is a thermodynamic resource that may effectively double the power output. The efficiency, however, is not affected. We find that coherence is not an essential asset in such multilevel-based heat engines. The existence of two thermalization pathways sharing a common ground state suffices for power enhancement.

  18. Analysis of postoperative complications for superficial liposuction: a review of 2398 cases.

    PubMed

    Kim, Youn Hwan; Cha, Sang Myun; Naidu, Shenthilkumar; Hwang, Weon Jung

    2011-02-01

    Superficial liposuction has found its application in maximizing and creating a lifting effect to achieve a better aesthetic result. Due to initial high complication rates, these procedures were generally accepted as risky. In a response to the increasing concerns over the safety and efficacy of superficial liposuction, the authors describe their 14-year experience of performing superficial liposuction and analysis of postoperative complications associated with these procedures. From March of 1995 to December of 2008, the authors performed superficial liposuction on 2398 patients. Three subgroups were incorporated according to liposuction methods as follows: power-assisted liposuction alone (subgroup 1), power-assisted liposuction combined with ultrasound energy (subgroup 2), and power-assisted liposuction combined with external ultrasound and postoperative Endermologie (subgroup 3). Statistical analyses for complications were performed among subgroups. The mean age was 42.8 years, mean body mass index was 27.9 kg/m2, and mean volume of total aspiration was 5045 cc. Overall complication rate was 8.6 percent (206 patients). Four cases of skin necroses and two cases of infections were included. The most common complication was postoperative contour irregularity. Power-assisted liposuction combined with external ultrasound with or without postoperative Endermologie was seen to decrease the overall complication rate, contour irregularity, and skin necrosis. There were no statistical differences regarding other complications. Superficial liposuction has potential risks for higher complications compared with conventional suction techniques, especially postoperative contour irregularity, which can be minimized with proper selection of candidates for the procedure, avoiding overzealous suctioning of superficial layer, and using a combination of ultrasound energy techniques.

  19. Optimization and performance comparison for galloping-based piezoelectric energy harvesters with alternating-current and direct-current interface circuits

    NASA Astrophysics Data System (ADS)

    Tan, Ting; Yan, Zhimiao; Lei, Hong

    2017-07-01

    Galloping-based piezoelectric energy harvesters scavenge small-scale wind energy and convert it into electrical energy. For piezoelectric energy harvesting with the same vibrational source (galloping) but different (alternating-current (AC) and direct-current (DC)) interfaces, general analytical solutions of the electromechanical coupled distributed parameter model are proposed. Galloping is theoretically proven to appear when the linear aerodynamic negative damping overcomes the electrical damping and mechanical damping. The harvested power is demonstrated as being done by the electrical damping force. Via tuning the load resistance to its optimal value for optimal or maximal electrical damping, the harvested power of the given structure with the AC/DC interface is maximized. The optimal load resistances and the corresponding performances of such two systems are compared. The optimal electrical damping are the same but with different optimal load resistances for the systems with the AC and DC interfaces. At small wind speeds where the optimal electrical damping can be realized by only tuning the load resistance, the performances of such two energy harvesting systems, including the minimal onset speeds to galloping, maximal harvested powers and corresponding tip displacements are almost the same. Smaller maximal electrical damping with larger optimal load resistance is found for the harvester with the DC interface when compared to those for the harvester with the AC interface. At large wind speeds when the maximal electrical damping rather than the optimal electrical damping can be reached by tuning the load resistance alone, the harvester with the AC interface circuit is recommended for a higher maximal harvested power with a smaller tip displacement. This study provides a method using the general electrical damping to connect and compare the performances of piezoelectric energy harvesters with same excitation source but different interfaces.

  20. Maximizing optical efficacy and color gamut in projection applications by combining four laser wavelengths

    NASA Astrophysics Data System (ADS)

    Wallhead, Ian; Ocaña, Roberto

    2014-05-01

    Laser projection devices should be designed to maximize their luminous efficacy and color gamut. This is for two main reasons. Firstly, being either stand alone devices or embedded in other products, they could be powered by battery, and lifetime is an important factor. Secondly, the increasing use of lasers to project images calls for a consideration of eye safety issues. The brightness of the projected image may be limited by the Class II accessible emission limit. There is reason to believe that current laser beam scanning projection technology is already close to the power ceiling based on eye safety limits. Consequently, it would be desirable to improve luminous efficacy to increase the output luminous flux whilst maintaining or improving color gamut for the same eye-safe optical power limit. Here we present a novel study about the combination of four laser wavelengths in order to maximize both color gamut and efficacy to produce the color white. Firstly, an analytic method to calculate efficacy as function of both four laser wavelengths and four laser powers is derived. Secondly we provide a new way to present the results by providing the diagram efficacy vs color gamut area that summarizes the performance of any wavelength combination for projection purposes. The results indicate that the maximal efficacy for the D65 white is only achievable by using a suitable combination of both laser power ratios and wavelengths.

  1. How to make optimal use of maximal multipartite entanglement in clock synchronization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ren, Changliang; Hofmann, Holger F.

    2014-12-04

    We introduce a multi-party quantum clock synchronization protocol that makes optimal use of the maximal multipartite entanglement of GHZ-type states. The measurement statistics of the protocol are analyzed and the efficiency is evaluated.

  2. Scale-free avalanche dynamics in the stock market

    NASA Astrophysics Data System (ADS)

    Bartolozzi, M.; Leinweber, D. B.; Thomas, A. W.

    2006-10-01

    Self-organized criticality (SOC) has been claimed to play an important role in many natural and social systems. In the present work we empirically investigate the relevance of this theory to stock-market dynamics. Avalanches in stock-market indices are identified using a multi-scale wavelet-filtering analysis designed to remove Gaussian noise from the index. Here, new methods are developed to identify the optimal filtering parameters which maximize the noise removal. The filtered time series is reconstructed and compared with the original time series. A statistical analysis of both high-frequency Nasdaq E-mini Futures and daily Dow Jones data is performed. The results of this new analysis confirm earlier results revealing a robust power-law behaviour in the probability distribution function of the sizes, duration and laminar times between avalanches. This power-law behaviour holds the potential to be established as a stylized fact of stock market indices in general. While the memory process, implied by the power-law distribution of the laminar times, is not consistent with classical models for SOC, we note that a power-law distribution of the laminar times cannot be used to rule out self-organized critical behaviour.

  3. Effects of six weeks of beta-hydroxy-beta-methylbutyrate (HMB) and HMB/creatine supplementation on strength, power, and anthropometry of highly trained athletes.

    PubMed

    O'Connor, Donna M; Crowe, Melissa J

    2007-05-01

    This study investigated the effects of 6 weeks of dietary supplementation of beta-hydroxy-beta-methylbutyrate (HMB) and HMB combined with creatine monohydrate (HMBCr) on the muscular strength and endurance, leg power, and anthropometry of elite male rugby league players. The subjects were divided into a control group (n = 8), a HMB group (n = 11; 3 g.d(-1)) or a HMBCr group (n = 11; 12 g.d(-1) with 3 g HMB, 3 g Cr, 6 g carbohydrates). Three repetition maximum lifts on bench press, deadlifts, prone row, and shoulder press, maximum chin-up repetitions, 10-second maximal cycle test, body mass, girths, and sum of skinfolds were assessed pre- and postsupplementation. Statistical analysis revealed no effect of HMB or HMBCr on any parameter compared with presupplementation measures or the control group. HMB and HMBCr were concluded to have no ergogenic effect on muscular strength and endurance, leg power, or anthropometry when taken orally by highly trained male athletes over 6 weeks.

  4. The maximal cooling power of magnetic and thermoelectric refrigerators with La(FeCoSi)13 alloys

    NASA Astrophysics Data System (ADS)

    Skokov, K. P.; Karpenkov, A. Yu.; Karpenkov, D. Yu.; Gutfleisch, O.

    2013-05-01

    Using our data on magnetic entropy change ΔSm, adiabatic temperature change ΔTad and heat capacity CH for La(FeCoSi)13 alloys, the upper limit of heat Qc transferred per cycle, and the lowest limit of consumed work Wc were established for magnetic refrigerators operating in Δμ0H =1.9 T. In order to estimate the cooling power, attributable to thermoelectric refrigerators with La(FeCoSi)13, thermal conductivity λ, resistivity ρ, and Seebeck coefficient α were measured and the maximal cooling power QL, the input power Pi, and coefficient of performance have been calculated.

  5. Simultaneous Wireless Power Transfer and Secure Multicasting in Cooperative Decode-and-Forward Relay Networks.

    PubMed

    Lee, Jong-Ho; Sohn, Illsoo; Kim, Yong-Hwa

    2017-05-16

    In this paper, we investigate simultaneous wireless power transfer and secure multicasting via cooperative decode-and-forward (DF) relays in the presence of multiple energy receivers and eavesdroppers. Two scenarios are considered under a total power budget: maximizing the minimum harvested energy among the energy receivers under a multicast secrecy rate constraint; and maximizing the multicast secrecy rate under a minimum harvested energy constraint. For both scenarios, we solve the transmit power allocation and relay beamformer design problems by using semidefinite relaxation and bisection technique. We present numerical results to analyze the energy harvesting and secure multicasting performances in cooperative DF relay networks.

  6. Simultaneous Wireless Power Transfer and Secure Multicasting in Cooperative Decode-and-Forward Relay Networks

    PubMed Central

    Lee, Jong-Ho; Sohn, Illsoo; Kim, Yong-Hwa

    2017-01-01

    In this paper, we investigate simultaneous wireless power transfer and secure multicasting via cooperative decode-and-forward (DF) relays in the presence of multiple energy receivers and eavesdroppers. Two scenarios are considered under a total power budget: maximizing the minimum harvested energy among the energy receivers under a multicast secrecy rate constraint; and maximizing the multicast secrecy rate under a minimum harvested energy constraint. For both scenarios, we solve the transmit power allocation and relay beamformer design problems by using semidefinite relaxation and bisection technique. We present numerical results to analyze the energy harvesting and secure multicasting performances in cooperative DF relay networks. PMID:28509841

  7. Detailed statistical assessment of the characteristics of the ESMO Magnitude of Clinical Benefit Scale (ESMO-MCBS) threshold rules.

    PubMed

    Dafni, Urania; Karlis, Dimitris; Pedeli, Xanthi; Bogaerts, Jan; Pentheroudakis, George; Tabernero, Josep; Zielinski, Christoph C; Piccart, Martine J; de Vries, Elisabeth G E; Latino, Nicola Jane; Douillard, Jean-Yves; Cherny, Nathan I

    2017-01-01

    The European Society for Medical Oncology (ESMO) has developed the ESMO Magnitude of Clinical Benefit Scale (ESMO-MCBS), a tool to assess the magnitude of clinical benefit from new cancer therapies. Grading is guided by a dual rule comparing the relative benefit (RB) and the absolute benefit (AB) achieved by the therapy to prespecified threshold values. The ESMO-MCBS v1.0 dual rule evaluates the RB of an experimental treatment based on the lower limit of the 95%CI (LL95%CI) for the hazard ratio (HR) along with an AB threshold. This dual rule addresses two goals: inclusiveness: not unfairly penalising experimental treatments from trials designed with adequate power targeting clinically meaningful relative benefit; and discernment: penalising trials designed to detect a small inconsequential benefit. Based on 50 000 simulations of plausible trial scenarios, the sensitivity and specificity of the LL95%CI rule and the ESMO-MCBS dual rule, the robustness of their characteristics for reasonable power and range of targeted and true HRs, are examined. The per cent acceptance of maximal preliminary grade is compared with other dual rules based on point estimate (PE) thresholds for RB. For particularly small or particularly large studies, the observed benefit needs to be relatively big for the ESMO-MCBS dual rule to be satisfied and the maximal grade awarded. Compared with approaches that evaluate RB using the PE thresholds, simulations demonstrate that the MCBS approach better exhibits the desired behaviour achieving the goals of both inclusiveness and discernment. RB assessment using the LL95%CI for HR rather than a PE threshold has two advantages: it diminishes the probability of excluding big benefit positive studies from achieving due credit and, when combined with the AB assessment, it increases the probability of downgrading a trial with a statistically significant but clinically insignificant observed benefit.

  8. Detailed statistical assessment of the characteristics of the ESMO Magnitude of Clinical Benefit Scale (ESMO-MCBS) threshold rules

    PubMed Central

    Dafni, Urania; Karlis, Dimitris; Pedeli, Xanthi; Bogaerts, Jan; Pentheroudakis, George; Tabernero, Josep; Zielinski, Christoph C; Piccart, Martine J; de Vries, Elisabeth G E; Latino, Nicola Jane; Douillard, Jean-Yves; Cherny, Nathan I

    2017-01-01

    Background The European Society for Medical Oncology (ESMO) has developed the ESMO Magnitude of Clinical Benefit Scale (ESMO-MCBS), a tool to assess the magnitude of clinical benefit from new cancer therapies. Grading is guided by a dual rule comparing the relative benefit (RB) and the absolute benefit (AB) achieved by the therapy to prespecified threshold values. The ESMO-MCBS v1.0 dual rule evaluates the RB of an experimental treatment based on the lower limit of the 95%CI (LL95%CI) for the hazard ratio (HR) along with an AB threshold. This dual rule addresses two goals: inclusiveness: not unfairly penalising experimental treatments from trials designed with adequate power targeting clinically meaningful relative benefit; and discernment: penalising trials designed to detect a small inconsequential benefit. Methods Based on 50 000 simulations of plausible trial scenarios, the sensitivity and specificity of the LL95%CI rule and the ESMO-MCBS dual rule, the robustness of their characteristics for reasonable power and range of targeted and true HRs, are examined. The per cent acceptance of maximal preliminary grade is compared with other dual rules based on point estimate (PE) thresholds for RB. Results For particularly small or particularly large studies, the observed benefit needs to be relatively big for the ESMO-MCBS dual rule to be satisfied and the maximal grade awarded. Compared with approaches that evaluate RB using the PE thresholds, simulations demonstrate that the MCBS approach better exhibits the desired behaviour achieving the goals of both inclusiveness and discernment. Conclusions RB assessment using the LL95%CI for HR rather than a PE threshold has two advantages: it diminishes the probability of excluding big benefit positive studies from achieving due credit and, when combined with the AB assessment, it increases the probability of downgrading a trial with a statistically significant but clinically insignificant observed benefit. PMID:29067214

  9. Addition of 24-Hour Heart Rate Variability Parameters to the Cardiovascular Health Study Stroke Risk Score and Prediction of Incident Stroke: The Cardiovascular Health Study.

    PubMed

    Bodapati, Rohan K; Kizer, Jorge R; Kop, Willem J; Kamel, Hooman; Stein, Phyllis K

    2017-07-21

    Heart rate variability (HRV) characterizes cardiac autonomic functioning. The association of HRV with stroke is uncertain. We examined whether 24-hour HRV added predictive value to the Cardiovascular Health Study clinical stroke risk score (CHS-SCORE), previously developed at the baseline examination. N=884 stroke-free CHS participants (age 75.3±4.6), with 24-hour Holters adequate for HRV analysis at the 1994-1995 examination, had 68 strokes over ≤8 year follow-up (median 7.3 [interquartile range 7.1-7.6] years). The value of adding HRV to the CHS-SCORE was assessed with stepwise Cox regression analysis. The CHS-SCORE predicted incident stroke (HR=1.06 per unit increment, P =0.005). Two HRV parameters, decreased coefficient of variance of NN intervals (CV%, P =0.031) and decreased power law slope (SLOPE, P =0.033) also entered the model, but these did not significantly improve the c-statistic ( P =0.47). In a secondary analysis, dichotomization of CV% (LOWCV% ≤12.8%) was found to maximally stratify higher-risk participants after adjustment for CHS-SCORE. Similarly, dichotomizing SLOPE (LOWSLOPE <-1.4) maximally stratified higher-risk participants. When these HRV categories were combined (eg, HIGHCV% with HIGHSLOPE), the c-statistic for the model with the CHS-SCORE and combined HRV categories was 0.68, significantly higher than 0.61 for the CHS-SCORE alone ( P =0.02). In this sample of older adults, 2 HRV parameters, CV% and power law slope, emerged as significantly associated with incident stroke when added to a validated clinical risk score. After each parameter was dichotomized based on its optimal cut point in this sample, their composite significantly improved prediction of incident stroke during ≤8-year follow-up. These findings will require validation in separate, larger cohorts. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  10. Ultra short-term heart rate recovery after maximal exercise: relations to aerobic power in sportsmen.

    PubMed

    Ostojic, Sergej M; Stojanovic, Marko D; Calleja-Gonzalez, Julio

    2011-04-30

    The main aim of the study was to investigate whether different levels of aerobic power influence heart rate (HR) responses during the first minute of recovery following maximal exercise in athletes. Thirty-two young male soccer players were recruited for the study during the final week of their training prior to [corrected] the competition. Following the maximal exercise on treadmill the participants were placed supine for 60 s of HR recording. The time between exercise cessation and the recovery HR measurement was kept as short as possible. At the end of exercise (i.e., the start of recovery), HRs were [corrected] was similar in both trials. At both 10 s and 20 s of recovery period, the players characterized by high aerobic power (> 60 ml/kg/ min) revealed significantly lower HR as compared to their sub-elite counterparts (< 50 ml/kg/min; P < 0.05). No differences between the groups were found at later stages of the analyzed post-exercise HR. The data suggest that the athletes characterized by high aerobic capacity could be better adapted to maximal exercise with faster recovery HR immediately following an exercise test. These results generally suggest that the aerobic power along with autonomic modulation might have played a role in the ultra short-term cardiovascular responses to all-out exercise.

  11. Impacts of Maximizing Tendencies on Experience-Based Decisions.

    PubMed

    Rim, Hye Bin

    2017-06-01

    Previous research on risky decisions has suggested that people tend to make different choices depending on whether they acquire the information from personally repeated experiences or from statistical summary descriptions. This phenomenon, called as a description-experience gap, was expected to be moderated by the individual difference in maximizing tendencies, a desire towards maximizing decisional outcome. Specifically, it was hypothesized that maximizers' willingness to engage in extensive information searching would lead maximizers to make experience-based decisions as payoff distributions were given explicitly. A total of 262 participants completed four decision problems. Results showed that maximizers, compared to non-maximizers, drew more samples before making a choice but reported lower confidence levels on both the accuracy of knowledge gained from experiences and the likelihood of satisfactory outcomes. Additionally, maximizers exhibited smaller description-experience gaps than non-maximizers as expected. The implications of the findings and unanswered questions for future research were discussed.

  12. Maximal oxygen uptake and cardiorespiratory response to maximal 400-m free swimming, running and cycling tests in competitive swimmers.

    PubMed

    Rodríguez, F A

    2000-06-01

    This study compared the cardiorespiratory response of trained swimmers to 400-m unimpeded front crawl swimming (SW), treadmill running (TR) and ergometer cycling (EC) maximal exercise tests, and evaluated the validity and specificity of a method to measure maximal aerobic power in swimming. Two series of experiments were conducted. In series A (n=15), comparisons were made between VO2peak and other cardiorespiratory variables in three maximal tests: after 400-m SW, and during incremental TR and EC. In series B, VO2 peak and related variables were measured after SW and during EC (n=33). No significant differences were observed between VO2peak and VE in the three modes of exercise, although SW values tended to be higher. After SW, maximal ventilatory response was characterized by higher tidal volumes (VT) and lower respiratory rates (fR) as compared with TR and EC. The highest heart rate values (fH) were also observed in TR, followed by EC and SW. In series B, no significant differences were observed either in peak VO2 or VE, but fH was also lower in SW. A maximal 400-m unimpeded freestyle SW test yields essentially equal or nonsignificantly higher peak VO2 and VE values than during maximal TR or EC tests in trained swimmers. The specific maximal cardiorespiratory response to the SW test is characterized by higher VT, lower fR, and lower fH. Breath-by-breath measurements during the immediate recovery after a 400-m voluntary maximal swim is proposed as a valid and specific test for directly measuring maximal metabolic parameters and evaluating specific maximal aerobic power in swimming.

  13. Power enhancement of heat engines via correlated thermalization in a three-level “working fluid”

    PubMed Central

    Gelbwaser-Klimovsky, David; Niedenzu, Wolfgang; Brumer, Paul; Kurizki, Gershon

    2015-01-01

    We explore means of maximizing the power output of a heat engine based on a periodically-driven quantum system that is constantly coupled to hot and cold baths. It is shown that the maximal power output of such a heat engine whose “working fluid” is a degenerate V-type three-level system is that generated by two independent two-level systems. Hence, level degeneracy is a thermodynamic resource that may effectively double the power output. The efficiency, however, is not affected. We find that coherence is not an essential asset in such multilevel-based heat engines. The existence of two thermalization pathways sharing a common ground state suffices for power enhancement. PMID:26394838

  14. Utilization of Model Predictive Control to Balance Power Absorption Against Load Accumulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abbas, Nikhar; Tom, Nathan M

    2017-06-03

    Wave energy converter (WEC) control strategies have been primarily focused on maximizing power absorption. The use of model predictive control strategies allows for a finite-horizon, multiterm objective function to be solved. This work utilizes a multiterm objective function to maximize power absorption while minimizing the structural loads on the WEC system. Furthermore, a Kalman filter and autoregressive model were used to estimate and forecast the wave exciting force and predict the future dynamics of the WEC. The WEC's power-take-off time-averaged power and structural loads under a perfect forecast assumption in irregular waves were compared against results obtained from the Kalmanmore » filter and autoregressive model to evaluate model predictive control performance.« less

  15. Utilization of Model Predictive Control to Balance Power Absorption Against Load Accumulation: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abbas, Nikhar; Tom, Nathan

    Wave energy converter (WEC) control strategies have been primarily focused on maximizing power absorption. The use of model predictive control strategies allows for a finite-horizon, multiterm objective function to be solved. This work utilizes a multiterm objective function to maximize power absorption while minimizing the structural loads on the WEC system. Furthermore, a Kalman filter and autoregressive model were used to estimate and forecast the wave exciting force and predict the future dynamics of the WEC. The WEC's power-take-off time-averaged power and structural loads under a perfect forecast assumption in irregular waves were compared against results obtained from the Kalmanmore » filter and autoregressive model to evaluate model predictive control performance.« less

  16. Combined electronic and thermodynamic approaches for enhancing the thermoelectric properties of Ti-doped PbTe.

    PubMed

    Komisarchik, G; Gelbstein, Y; Fuks, D

    2016-11-30

    Lead telluride based compounds are of great interest due to their enhanced thermoelectric transport properties. Nevertheless, the donor type impurities in this class of materials are currently mainly limited and alternative types of donor impurities are still required for optimizing the thermoelectric performance. In the current research titanium as a donor impurity in PbTe is examined. Although titanium is known to form resonant levels above the conduction band in PbTe, it does not enhance the thermo-power beyond the classical predictions. Recent experiments showed that alloying with a small amount of Ti (∼0.1 at%) gives a significant increase in the figure of merit. In the current research ab initio calculations were applied in order to correlate the reported experimental results with a thermoelectric optimization model. It was found that a Ti concentration of ∼1.4 at% in the Pb sublattice is expected to maximize the thermoelectric power factor. Using a statistical thermodynamic approach and in agreement with the previously reported appearance of a secondary intermetallic phase, the actual Ti solubility limit in PbTe is found to be ∼0.3 at%. Based on the proposed model, the mechanism for the formation of the previously observed secondary phase is attributed to phase separation reactions, characterized by a positive enthalpy of formation in the system. With extrapolation of the obtained ab initio results, it is demonstrated that lower Ti-doping concentrations than previously experimentally reported ones are expected to provide power factor values close to the maximal one, making doping with Ti a promising opportunity for the generation of highly efficient n-type PbTe-based thermoelectric materials.

  17. A boundary-optimized rejection region test for the two-sample binomial problem.

    PubMed

    Gabriel, Erin E; Nason, Martha; Fay, Michael P; Follmann, Dean A

    2018-03-30

    Testing the equality of 2 proportions for a control group versus a treatment group is a well-researched statistical problem. In some settings, there may be strong historical data that allow one to reliably expect that the control proportion is one, or nearly so. While one-sample tests or comparisons to historical controls could be used, neither can rigorously control the type I error rate in the event the true control rate changes. In this work, we propose an unconditional exact test that exploits the historical information while controlling the type I error rate. We sequentially construct a rejection region by first maximizing the rejection region in the space where all controls have an event, subject to the constraint that our type I error rate does not exceed α for any true event rate; then with any remaining α we maximize the additional rejection region in the space where one control avoids the event, and so on. When the true control event rate is one, our test is the most powerful nonrandomized test for all points in the alternative space. When the true control event rate is nearly one, we demonstrate that our test has equal or higher mean power, averaging over the alternative space, than a variety of well-known tests. For the comparison of 4 controls and 4 treated subjects, our proposed test has higher power than all comparator tests. We demonstrate the properties of our proposed test by simulation and use our method to design a malaria vaccine trial. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  18. Effect of traditional resistance and power training using rated perceived exertion for enhancement of muscle strength, power, and functional performance.

    PubMed

    Tiggemann, Carlos Leandro; Dias, Caroline Pieta; Radaelli, Regis; Massa, Jéssica Cassales; Bortoluzzi, Rafael; Schoenell, Maira Cristina Wolf; Noll, Matias; Alberton, Cristine Lima; Kruel, Luiz Fernando Martins

    2016-04-01

    The present study compared the effects of 12 weeks of traditional resistance training and power training using rated perceived exertion (RPE) to determine training intensity on improvements in strength, muscle power, and ability to perform functional task in older women. Thirty healthy elderly women (60-75 years) were randomly assigned to traditional resistance training group (TRT; n = 15) or power training group (PT; n = 15). Participants trained twice a week for 12 weeks using six exercises. The training protocol was designed to ascertain that participants exercised at an RPE of 13-18 (on a 6-20 scale). Maximal dynamic strength, muscle power, and functional performance of lower limb muscles were assessed. Maximal dynamic strength muscle strength leg press (≈58 %) and knee extension (≈20 %) increased significantly (p < 0.001) and similarly in both groups after training. Muscle power also increased with training (≈27 %; p < 0.05), with no difference between groups. Both groups also improved their functional performance after training period (≈13 %; p < 0.001), with no difference between groups. The present study showed that TRT and PT using RPE scale to control intensity were significantly and similarly effective in improving maximal strength, muscle power, and functional performance of lower limbs in elderly women.

  19. Unifying quantum heat transfer in a nonequilibrium spin-boson model with full counting statistics

    NASA Astrophysics Data System (ADS)

    Wang, Chen; Ren, Jie; Cao, Jianshu

    2017-02-01

    To study the full counting statistics of quantum heat transfer in a driven nonequilibrium spin-boson model, we develop a generalized nonequilibrium polaron-transformed Redfield equation with an auxiliary counting field. This enables us to study the impact of qubit-bath coupling ranging from weak to strong regimes. Without external modulations, we observe maximal values of both steady-state heat flux and noise power in moderate coupling regimes, below which we find that these two transport quantities are enhanced by the finite-qubit-energy bias. With external modulations, the geometric-phase-induced heat flux shows a monotonic decrease upon increasing the qubit-bath coupling at zero qubit energy bias (without bias). While under the finite-qubit-energy bias (with bias), the geometric-phase-induced heat flux exhibits an interesting reversal behavior in the strong coupling regime. Our results unify the seemingly contradictory results in weak and strong qubit-bath coupling regimes and provide detailed dissections for the quantum fluctuation of nonequilibrium heat transfer.

  20. Influence of resistance load on neuromuscular response to vibration training.

    PubMed

    Luo, Jin; Clarke, Michael; McNamara, Brian; Moran, Kieran

    2009-03-01

    The purpose of this study was to examine the influence of resistance load on the acute and acute residual effects of vibration training, with vibration applied directly to the bicep tendon in a maximal-effort dynamic resistance exercise (3 sets of maximal-effort bicep curls). Eleven participants were exposed to 4 training conditions in random order: exercise with 1 of 2 different loads (40% 1-repetition maximum [RM] or 70% 1RM load) combined with 1 of 2 vibration conditions (vibration [1.2 mm, 65 Hz] or sham vibration). Five minutes before and after the exercise, a set of maximal-effort bicep curls with a load of either 40 or 70% 1RM was performed as the pre- and posttraining test. Concentric elbow joint angular velocity, moment and power, and bicep root mean square electromyography (EMGrms) were measured during training and in the pre- and posttraining tests. The results show that during training (acute effect) and at 5 minutes after training (acute residual effect), vibration did not induce a significant change in EMGrms, mean and peak angular velocities, moment and power, time to peak power, and initial power at 100 milliseconds after the start of the concentric phase for either resistance load. Therefore, in aiming to train neuromuscular output using maximal-effort dynamic contractions (40 and 70% 1RM), there is no benefit in employing direct vibration, at least with a 1.2-mm amplitude and 65-Hz frequency. However, the amplitude of 1.2 mm may be too high to effectively stimulate neuromuscular output in maximal-effort dynamic contractions per se.

  1. The Effects of a Maximal Power Training Cycle on the Strength, Maximum Power, Vertical Jump Height and Acceleration of High-Level 400-Meter Hurdlers

    PubMed Central

    Balsalobre-Fernández, Carlos; Tejero-González, Carlos Mª; del Campo-Vecino, Juan; Alonso-Curiel, Dionisio

    2013-01-01

    The aim of this study was to determine the effects of a power training cycle on maximum strength, maximum power, vertical jump height and acceleration in seven high-level 400-meter hurdlers subjected to a specific training program twice a week for 10 weeks. Each training session consisted of five sets of eight jump-squats with the load at which each athlete produced his maximum power. The repetition maximum in the half squat position (RM), maximum power in the jump-squat (W), a squat jump (SJ), countermovement jump (CSJ), and a 30-meter sprint from a standing position were measured before and after the training program using an accelerometer, an infra-red platform and photo-cells. The results indicated the following statistically significant improvements: a 7.9% increase in RM (Z=−2.03, p=0.021, δc=0.39), a 2.3% improvement in SJ (Z=−1.69, p=0.045, δc=0.29), a 1.43% decrease in the 30-meter sprint (Z=−1.70, p=0.044, δc=0.12), and, where maximum power was produced, a change in the RM percentage from 56 to 62% (Z=−1.75, p=0.039, δc=0.54). As such, it can be concluded that strength training with a maximum power load is an effective means of increasing strength and acceleration in high-level hurdlers. PMID:23717361

  2. The effects of a maximal power training cycle on the strength, maximum power, vertical jump height and acceleration of high-level 400-meter hurdlers.

    PubMed

    Balsalobre-Fernández, Carlos; Tejero-González, Carlos M; Del Campo-Vecino, Juan; Alonso-Curiel, Dionisio

    2013-03-01

    The aim of this study was to determine the effects of a power training cycle on maximum strength, maximum power, vertical jump height and acceleration in seven high-level 400-meter hurdlers subjected to a specific training program twice a week for 10 weeks. Each training session consisted of five sets of eight jump-squats with the load at which each athlete produced his maximum power. The repetition maximum in the half squat position (RM), maximum power in the jump-squat (W), a squat jump (SJ), countermovement jump (CSJ), and a 30-meter sprint from a standing position were measured before and after the training program using an accelerometer, an infra-red platform and photo-cells. The results indicated the following statistically significant improvements: a 7.9% increase in RM (Z=-2.03, p=0.021, δc=0.39), a 2.3% improvement in SJ (Z=-1.69, p=0.045, δc=0.29), a 1.43% decrease in the 30-meter sprint (Z=-1.70, p=0.044, δc=0.12), and, where maximum power was produced, a change in the RM percentage from 56 to 62% (Z=-1.75, p=0.039, δc=0.54). As such, it can be concluded that strength training with a maximum power load is an effective means of increasing strength and acceleration in high-level hurdlers.

  3. High power 808 nm vertical cavity surface emitting laser with multi-ring-shaped-aperture structure

    NASA Astrophysics Data System (ADS)

    Hao, Y. Q.; Shang, C. Y.; Feng, Y.; Yan, C. L.; Zhao, Y. J.; Wang, Y. X.; Wang, X. H.; Liu, G. J.

    2011-02-01

    The carrier conglomeration effect has been one of the main problems in developing electrically pumped high power vertical cavity surface emitting laser (VCSEL) with large aperture. We demonstrate a high power 808 nm VCSEL with multi-ring-shaped-aperture (MRSA) to weaken the carrier conglomeration effect. Compared with typical VCSEL with single large aperture (SLA), the 300-μm-diameter VCSEL with MRSA has more uniform near field and far field patterns. Moreover, MRSA laser exhibits maximal CW light output power 0.3 W which is about 3 times that of SLA laser. And the maximal wall-plug efficiency of 17.4% is achieved, higher than that of SLA laser by 10%.

  4. Leg strength or velocity of movement: which is more influential on the balance of mobility limited elders?

    PubMed

    Mayson, Douglas J; Kiely, Dan K; LaRose, Sharon I; Bean, Jonathan F

    2008-12-01

    To determine which component of leg power (maximal limb strength or limb velocity) is more influential on balance performance in mobility limited elders. In this cross-sectional analysis we evaluated 138 community-dwelling older adults with mobility limitation. Balance was measured using the Unipedal Stance Test, the Berg Balance Test (BERG), the Dynamic Gait Index, and the performance-oriented mobility assessment. We measured one repetition maximum strength and power at 40% one repetition maximum strength, from which velocity was calculated. The associations between maximal estimated leg strength and velocity with balance performance were examined using separate multivariate logistic regression models. Strength was found to be associated [odds ratio of 1.06 (95% confidence interval, 1.01-1.11)] with performance on the Unipedal Stance Test, whereas velocity showed no statistically significant association. In contrast, velocity was consistently associated with performance on all composite measures of balance (BERG 14.23 [1.84-109.72], performance-oriented mobility assessment 33.92 [3.69-312.03], and Dynamic Gait Index 35.80 [4.77-268.71]). Strength was only associated with the BERG 1.08 (1.01-1.14). Higher leg press velocity is associated with better performance on the BERG, performance-oriented mobility assessment, and Dynamic Gait Index, whereas greater leg strength is associated with better performance on the Unipedal Stance Test and the BERG. These findings are likely related to the intrinsic qualities of each test and emphasize the relevance of limb velocity.

  5. Role of sufficient statistics in stochastic thermodynamics and its implication to sensory adaptation

    NASA Astrophysics Data System (ADS)

    Matsumoto, Takumi; Sagawa, Takahiro

    2018-04-01

    A sufficient statistic is a significant concept in statistics, which means a probability variable that has sufficient information required for an inference task. We investigate the roles of sufficient statistics and related quantities in stochastic thermodynamics. Specifically, we prove that for general continuous-time bipartite networks, the existence of a sufficient statistic implies that an informational quantity called the sensory capacity takes the maximum. Since the maximal sensory capacity imposes a constraint that the energetic efficiency cannot exceed one-half, our result implies that the existence of a sufficient statistic is inevitably accompanied by energetic dissipation. We also show that, in a particular parameter region of linear Langevin systems there exists the optimal noise intensity at which the sensory capacity, the information-thermodynamic efficiency, and the total entropy production are optimized at the same time. We apply our general result to a model of sensory adaptation of E. coli and find that the sensory capacity is nearly maximal with experimentally realistic parameters.

  6. Comparison of gait after Syme and transtibial amputation in children: factors that may play a role in function.

    PubMed

    Jeans, Kelly A; Karol, Lori A; Cummings, Donald; Singhal, Kunal

    2014-10-01

    Preservation of maximal limb length during amputation is often recommended to maximize the efficiency and symmetry of gait. The goals of this study were to determine (1) whether there are gait differences between children with a Syme (or Boyd) amputation and those with a transtibial-level amputation, and (2) whether the type of prosthetic foot affects gait and PODCI (Pediatric Outcomes Data Collection Instrument) outcomes. Sixty-four patients (age range, 4.7 to 19.2 years) with unilateral below-the-knee prosthesis use (forty-one in the Syme group and twenty-three in the transtibial group) underwent gait analysis and review of data for the involved limb. The twelve prosthetic foot types were categorized as designed for a high, medium, or low activity level (e.g., Flex foot, dynamic response foot, or SACH). Statistical analyses were conducted. Kinematic differences of <4° in total prosthetic ankle motion and 8° in external hip rotation were seen between the Syme and transtibial groups. Ankle power was greater in the transtibial group, whereas the Syme group had greater coronal-plane hip power (p < 0.05). Prosthetic ankle motion was significantly greater in the high compared with the medium and low-performance feet. However, the PODCI happiness score was higher in patients with low compared with medium-performance feet (p < 0.05). Small differences in prosthetic ankle motion and power were found between children with Syme and transtibial amputations. Ankle motion was greater in patients using high-performance feet (9% of the total cohort) compared with medium-performance (59%) and low-performance (31%) feet. Despite the increased ankle motion achieved with high-performance dynamic feet, this advantage was not reflected in peak power of the prosthetic ankle or the PODCI sports/physical functioning subscale. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  7. The effect of breathing an ambient low‐density, hyperoxic gas on the perceived effort of breathing and maximal performance of exercise in well‐trained athletes

    PubMed Central

    Ansley, L; Petersen, D; Thomas, A; Gibson, A St Clair; Robson‐Ansley, P; Noakes, T D

    2007-01-01

    Background The role of the perception of breathing effort in the regulation of performance of maximal exercise remains unclear. Aims To determine whether the perceived effort of ventilation is altered through substituting a less dense gas for normal ambient air and whether this substitution affects performance of maximal incremental exercise in trained athletes. Methods Eight highly trained cyclists (mean SD) maximal oxygen consumption (VO2max) = 69.9 (7.9) (mlO2/kg/min) performed two randomised maximal tests in a hyperbaric chamber breathing ambient air composed of either 35% O2/65% N2 (nitrox) or 35% O2/65% He (heliox). A ramp protocol was used in which power output was incremented at 0.5 W/s. The trials were separated by at least 48 h. The perceived effort of breathing was obtained via Borg Category Ratio Scales at 3‐min intervals and at fatigue. Oxygen consumption (VO2) and minute ventilation (VE) were monitored continuously. Results Breathing heliox did not change the sensation of dyspnoea: there were no differences between trials for the Borg scales at any time point. Exercise performance was not different between the nitrox and heliox trials (peak power output = 451 (58) and 453 (56) W), nor was VO2max (4.96 (0.61) and 4.88 (0.65) l/min) or maximal VE (157 (24) and 163 (22) l/min). Between‐trial variability in peak power output was less than either VO2max or maximal VE. Conclusion Breathing a less dense gas does not improve maximal performance of exercise or reduce the perception of breathing effort in highly trained athletes, although an attenuated submaximal tidal volume and VE with a concomitant reduction in VO2 suggests an improved gas exchange and reduced O2 cost of ventilation when breathing heliox. PMID:17062658

  8. Reliability of high-power QCW arrays

    NASA Astrophysics Data System (ADS)

    Feeler, Ryan; Junghans, Jeremy; Remley, Jennifer; Schnurbusch, Don; Stephens, Ed

    2010-02-01

    Northrop Grumman Cutting Edge Optronics has developed a family of arrays for high-power QCW operation. These arrays are built using CTE-matched heat sinks and hard solder in order to maximize the reliability of the devices. A summary of a recent life test is presented in order to quantify the reliability of QCW arrays and associated laser gain modules. A statistical analysis of the raw lifetime data is presented in order to quantify the data in such a way that is useful for laser system designers. The life tests demonstrate the high level of reliability of these arrays in a number of operating regimes. For single-bar arrays, a MTTF of 19.8 billion shots is predicted. For four-bar samples, a MTTF of 14.6 billion shots is predicted. In addition, data representing a large pump source is analyzed and shown to have an expected lifetime of 13.5 billion shots. This corresponds to an expected operational lifetime of greater than ten thousand hours at repetition rates less than 370 Hz.

  9. Subwavelength elastic joints connecting torsional waveguides to maximize the power transmission coefficient

    NASA Astrophysics Data System (ADS)

    Lee, Joong Seok; Lee, Il Kyu; Seung, Hong Min; Lee, Jun Kyu; Kim, Yoon Young

    2017-03-01

    Joints with slowly varying tapered shapes, such as linear or exponential profiles, are known to transmit incident wave power efficiently between two waveguides with dissimilar impedances. This statement is valid only when the considered joint length is longer than the wavelengths of the incident waves. When the joint length is shorter than the wavelengths, however, appropriate shapes of such subwavelength joints for efficient power transmission have not been explored much. In this work, considering one-dimensional torsional wave motion in a cylindrical elastic waveguide system, optimal shapes or radial profiles of a subwavelength joint maximizing the power transmission coefficient are designed by a gradient-based optimization formulation. The joint is divided into a number of thin disk elements using the transfer matrix approach and optimal radii of the disks are determined by iterative shape optimization processes for several single or bands of wavenumbers. Due to the subwavelength constraint, the optimized joint profiles were found to be considerably different from the slowly varying tapered shapes. Specifically, for bands of wavenumbers, peculiar gourd-like shapes were obtained as optimal shapes to maximize the power transmission coefficient. Numerical results from the proposed optimization formulation were also experimentally realized to verify the validity of the present designs.

  10. Comparison of Critical Power and W' Derived From 2 or 3 Maximal Tests.

    PubMed

    Simpson, Len Parker; Kordi, Mehdi

    2017-07-01

    Typically, accessing the asymptote (critical power; CP) and curvature constant (W') parameters of the hyperbolic power-duration relationship requires multiple constant-power exhaustive-exercise trials spread over several visits. However, more recently single-visit protocols and personal power meters have been used. This study investigated the practicality of using a 2-trial, single-visit protocol in providing reliable CP and W' estimates. Eight trained cyclists underwent 3- and 12-min maximal-exercise trials in a single session to derive (2-trial) CP and W' estimates. On a separate occasion a 5-min trial was performed, providing a 3rd trial to calculate (3-trial) CP and W'. There were no differences in CP (283 ± 66 vs 282 ± 65 W) or W' (18.72 ± 6.21 vs 18.27 ± 6.29 kJ) obtained from either the 2-trial or 3-trial method, respectively. After 2 familiarization sessions (completing a 3- and a 12-min trial on both occasions), both CP and W' remained reliable over additional separate measurements. The current study demonstrates that after 2 familiarization sessions, reliable CP and W' parameters can be obtained from trained cyclists using only 2 maximal-exercise trials. These results offer practitioners a practical, time-efficient solution for incorporating power-duration testing into applied athlete support.

  11. Power reserve following ramp-incremental cycling to exhaustion: implications for muscle fatigue and function.

    PubMed

    Hodgson, Michael D; Keir, Daniel A; Copithorne, David B; Rice, Charles L; Kowalchuk, John M

    2018-04-26

    In ramp-incremental cycling exercise, some individuals are capable of producing power output (PO) in excess of that produced at their limit of tolerance (LoT) while others cannot. This study sought to describe the: 1) prevalence of a "power reserve" within a group of young men (n=21; mean {plus minus} SD: age 25{plus minus}4 years; V̇O 2max 45{plus minus}8 ml•kg -1 •min -1 ); and 2) muscle fatigue characteristics of those with and without a power reserve. Power reserve was determined as the difference between peak PO achieved during a ramp-incremental test to exhaustion and maximal, single-leg isokinetic dynamometer power. Pre- versus post-exercise changes in voluntary and electrically-stimulated single-leg muscle force production measures (maximal voluntary contraction, voluntary activation, maximal isotonic velocity and isokinetic power; 1-, 10-, 50-Hz torque and 10/50-Hz ratio), V̇O 2max and constant-PO cycling time-to-exhaustion also were assessed. A dichotomy in power reserve was prevalent within the sample resulting in two groups: 1) "No Reserve" (NRES: <5% reserve; n=10) and 2) "Reserve" (RES: >15% reserve; n=11). At the LoT, all participants had achieved V̇O 2max . Muscle fatigue was evident in both groups, although the NRES group had greater reductions (p<0.05) in 10-Hz peak torque (PT), 10/50 Hz ratio, and maximal velocity. Time-to-exhaustion during the constant-PO test was 22{plus minus}16% greater (p<0.05) in RES (116{plus minus}19 s; PO = 317{plus minus}52 W) than in NRES (90{plus minus}23 s; PO = 337{plus minus}71 W), despite similar ramp-incremental exercise durations and V̇O 2max between groups. The differences in muscle fatigue and function between groups suggest that the mechanisms contributing to the LoT are not uniform.

  12. Alteration of swing leg work and power during human accelerated sprinting

    PubMed Central

    Matsubayashi, Takeo; Matsuo, Akifumi; Zushi, Koji

    2017-01-01

    ABSTRACT This study investigated changes in lower-extremity joint work and power during the swing phase in a maximal accelerated sprinting. Twelve male sprinters performed 60 m maximal sprints while motion data was recorded. Lower-extremity joint work and power during the swing phase of each stride for both legs were calculated. Positive hip and negative knee work (≈4.3 and ≈−2.9 J kg−1) and mean power (≈13.4 and ≈−8.7 W kg−1) during the entire swing phase stabilized or decreased after the 26.2±1.1 (9.69±0.25 m s−1) or 34.3±1.5 m mark (9.97±0.26 m s−1) during the acceleration phase. In contrast, the hip negative work and mean power during the early swing phase (≈7-fold and ≈3.7-fold increase in total), as well as the knee negative work and power during the terminal swing phase (≈1.85-fold and ≈2-fold increase in total), increased until maximal speed. Moreover, only the magnitudes of increases in negative work and mean power at hip and knee joints during the swing phase were positively associated with the increment of running speed from the middle of acceleration phase. These findings indicate that the roles of energy generation and absorption at the hip and knee joints shift around the middle of the acceleration phase as energy generation and absorption at the hip during the late swing phase and at the knee during early swing phase are generally maintained or decreased, and negative work and power at hip during the early swing phase and at knee during the terminal swing phase may be responsible for increasing running speed when approaching maximal speed. PMID:28396485

  13. Pseudo-spectral control of a novel oscillating surge wave energy converter in regular waves for power optimization including load reduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tom, Nathan M.; Yu, Yi -Hsiang; Wright, Alan D.

    The aim of this study is to describe a procedure to maximize the power-to-load ratio of a novel wave energy converter (WEC) that combines an oscillating surge wave energy converter with variable structural components. The control of the power-take-off torque will be on a wave-to-wave timescale, whereas the structure will be controlled statically such that the geometry remains the same throughout the wave period. Linear hydrodynamic theory is used to calculate the upper and lower bounds for the time-averaged absorbed power and surge foundation loads while assuming that the WEC motion remains sinusoidal. Previous work using pseudo-spectral techniques to solvemore » the optimal control problem focused solely on maximizing absorbed energy. This work extends the optimal control problem to include a measure of the surge foundation force in the optimization. The objective function includes two competing terms that force the optimizer to maximize power capture while minimizing structural loads. A penalty weight was included with the surge foundation force that allows control of the optimizer performance based on whether emphasis should be placed on power absorption or load shedding. Results from pseudo-spectral optimal control indicate that a unit reduction in time-averaged power can be accompanied by a greater reduction in surge-foundation force.« less

  14. Pseudo-spectral control of a novel oscillating surge wave energy converter in regular waves for power optimization including load reduction

    DOE PAGES

    Tom, Nathan M.; Yu, Yi -Hsiang; Wright, Alan D.; ...

    2017-04-18

    The aim of this study is to describe a procedure to maximize the power-to-load ratio of a novel wave energy converter (WEC) that combines an oscillating surge wave energy converter with variable structural components. The control of the power-take-off torque will be on a wave-to-wave timescale, whereas the structure will be controlled statically such that the geometry remains the same throughout the wave period. Linear hydrodynamic theory is used to calculate the upper and lower bounds for the time-averaged absorbed power and surge foundation loads while assuming that the WEC motion remains sinusoidal. Previous work using pseudo-spectral techniques to solvemore » the optimal control problem focused solely on maximizing absorbed energy. This work extends the optimal control problem to include a measure of the surge foundation force in the optimization. The objective function includes two competing terms that force the optimizer to maximize power capture while minimizing structural loads. A penalty weight was included with the surge foundation force that allows control of the optimizer performance based on whether emphasis should be placed on power absorption or load shedding. Results from pseudo-spectral optimal control indicate that a unit reduction in time-averaged power can be accompanied by a greater reduction in surge-foundation force.« less

  15. Energy-Efficient Next-Generation Passive Optical Networks Based on Sleep Mode and Heuristic Optimization

    NASA Astrophysics Data System (ADS)

    Zulai, Luis G. T.; Durand, Fábio R.; Abrão, Taufik

    2015-05-01

    In this article, an energy-efficiency mechanism for next-generation passive optical networks is investigated through heuristic particle swarm optimization. Ten-gigabit Ethernet-wavelength division multiplexing optical code division multiplexing-passive optical network next-generation passive optical networks are based on the use of a legacy 10-gigabit Ethernet-passive optical network with the advantage of using only an en/decoder pair of optical code division multiplexing technology, thus eliminating the en/decoder at each optical network unit. The proposed joint mechanism is based on the sleep-mode power-saving scheme for a 10-gigabit Ethernet-passive optical network, combined with a power control procedure aiming to adjust the transmitted power of the active optical network units while maximizing the overall energy-efficiency network. The particle swarm optimization based power control algorithm establishes the optimal transmitted power in each optical network unit according to the network pre-defined quality of service requirements. The objective is controlling the power consumption of the optical network unit according to the traffic demand by adjusting its transmitter power in an attempt to maximize the number of transmitted bits with minimum energy consumption, achieving maximal system energy efficiency. Numerical results have revealed that it is possible to save 75% of energy consumption with the proposed particle swarm optimization based sleep-mode energy-efficiency mechanism compared to 55% energy savings when just a sleeping-mode-based mechanism is deployed.

  16. Effects of hydraulic resistance circuit training on physical fitness components of potential relevance to +Gz tolerance.

    PubMed

    Jacobs, I; Bell, D G; Pope, J; Lee, W

    1987-08-01

    Recent studies carried out in the United States and Sweden have demonstrated that strength training can improve +Gz acceleration tolerance. Based on these findings, the Canadian Forces have introduced a training program for aircrew of high performance aircraft. This report describes the changes in physical fitness components considered relevant to +Gz tolerance after 12 weeks of training with this program. Prior to beginning training, 45 military personnel were tested, but only 20 completed a minimum of 24 training sessions. The following variables were measured in these 20 subjects before and after training: maximal strength of several large muscle groups during isokinetic contractions, maximal aerobic power and an endurance fitness index, maximal anaerobic power, anthropometric characteristics, and maximal expiratory pressure generated during exhalation. Training involved hydraulic resistance circuit training 2-4 times/week. The circuit consisted of 3 consecutive sets at each of 8 stations using Hydra-Gym equipment. The exercise:rest ratio was 20:40 s for the initial 4 training weeks and was then changed to 30:50. After training the changes in anthropometric measurements suggested that lean body mass was increased. Small, but significant, increases were also measured in muscle strength during bench press, biceps curls, squats, knee extension, and knee flexion. Neither maximal anaerobic power (i.e. muscular endurance) nor maximal expiratory pressure were changed after the training. Indices of endurance fitness were also increased in the present study. The relatively small increases in strength are probably due to the design of the exercise:rest ratio which resulted in improved strength and aerobic fitness.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Factors in Maximal Power Production and in Exercise Endurance Relative to Maximal Power

    DTIC Science & Technology

    1988-10-13

    Mechanical efficiency of fast -and slow - twitch muscle fibers in mnan during cycling. J. ADLi Physiol.:Reespirat. Environ. Exercise Physiol. 47: 263- 267...R.S. Hikida, and F.C. Hagerman. Myofibrillar ATPase activity in hu-man muscle fast - twitch subtypes. Histochem. 78: 405-408, 1983. 31. Suzuki, Y...capacity and muscle fibre composition in mnan. J. Physiol (London) 354: 73P, 1984. 21. Margaria, R., P. Aghemo, and E. Rovelli. Measurement of muscular

  18. Power frequency spectrum analysis of surface EMG signals of upper limb muscles during elbow flexion - A comparison between healthy subjects and stroke survivors.

    PubMed

    Angelova, Silvija; Ribagin, Simeon; Raikova, Rositsa; Veneva, Ivanka

    2018-02-01

    After a stroke, motor units stop working properly and large, fast-twitch units are more frequently affected. Their impaired functions can be investigated during dynamic tasks using electromyographic (EMG) signal analysis. The aim of this paper is to investigate changes in the parameters of the power/frequency function during elbow flexion between affected, non-affected, and healthy muscles. Fifteen healthy subjects and ten stroke survivors participated in the experiments. Electromyographic data from 6 muscles of the upper limbs during elbow flexion were filtered and normalized to the amplitudes of EMG signals during maximal isometric tasks. The moments when motion started and when the flexion angle reached its maximal value were found. Equal intervals of 0.3407 s were defined between these two moments and one additional interval before the start of the flexion (first one) was supplemented. For each of these intervals the power/frequency function of EMG signals was calculated. The mean (MNF) and median frequencies (MDF), the maximal power (MPw) and the area under the power function (APw) were calculated. MNF was always higher than MDF. A significant decrease in these frequencies was found in only three post-stroke survivors. The frequencies in the first time interval were nearly always the highest among all intervals. The maximal power was nearly zero during first time interval and increased during the next ones. The largest values of MPw and APw were found for the flexor muscles and they increased for the muscles of the affected arm compared to the non-affected one of stroke survivors. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. The contribution of volume, technique, and load to single-repetition and total-repetition kinematics and kinetics in response to three loading schemes.

    PubMed

    Crewther, Blair T; Cronin, John; Keogh, Justin W L

    2008-11-01

    This study examined the effect of volume, technique, and load upon single-repetition and total-repetition kinematics and kinetics during three loading schemes. Eleven recreationally trained males each performed a power (8 sets of 6 repetitions at 45% of one-repetition maximum [1RM], 3-minute rest periods, explosive and ballistic movements), hypertrophy (10 sets of 10 repetitions at 75% 1RM, 2-minute rest periods, controlled movements), and maximal strength (6 sets of 4 repetitions at 88% 1RM, 4-minute rest periods, explosive intent) scheme involving squats. Examination of repetition data showed that load intensity (% 1RM) generally had a direct effect on forces, contraction times, impulses, and work (i.e., increasing with load), whereas power varied across loads (p < 0.001). However, total-repetition forces, contraction times, impulses, work, and power were all greater in the hypertrophy scheme (p < 0.001), because of the greater number of repetitions performed (volume) as well as lifting technique. No differences in total forces were found between the equal-volume power and maximal strength schemes, but the former did produce greater total contraction times, work, and power (p < 0.001), which may also be attributed to repetition and technique differences. Total impulses were the only variable greater in the maximal strength scheme (p < 0.001). Thus, the interaction of load, volume, and technique plays an important role in determining the mechanical responses (stimuli) afforded by these workouts. These findings may explain disparities cited within research, regarding the effectiveness of different loading strategies for hypertrophy, maximal strength, and power adaptation.

  20. Force production in the rugby union scrum.

    PubMed

    Quarrie, K L; Wilson, B D

    2000-04-01

    In this study, we examined the relationship between anthropometric, strength and power characteristics of rugby forwards, their body position when scrummaging, and their ability to apply force when scrummaging. Force applied to an instrumented scrum machine was measured for 56 players, both individually and as scrum packs. Measurements of body position for individuals were made by digitizing videotape records of the trials. Forty players subsequently had their anthropometry assessed and completed several strength and power tests. Body mass, each component of somatotype, maximal anaerobic power developed on a cycle ergometer, and isokinetic knee extension strength correlated significantly with individual scrummaging force. A regression model (P < 0.001) including body mass, mesomorphy, maximal anaerobic power and hip angle while in the scrummaging position accounted for 45% of the variance in individual scrummaging force. The packs that produced the largest scrummaging forces were, in general, characterized by a greater pack force to sum of individual force ratio than the packs producing lower forces. Our results emphasize the need for a scrum pack to develop technique and coordination as a unit to maximize scrummaging force.

  1. Relationships between self-reported health related quality of life and measures of standardized exercise capacity and metabolic efficiency in a middle-aged and aged healthy population.

    PubMed

    Lindholm, E; Brevinge, H; Bergh, C H; Körner, U; Lundholm, K

    2003-08-01

    The purpose of this study was to evaluate to what extent self-reported health related quality of life (HRQL), assessed by the Swedish standard version of the Medical Outcome Study Short-Form 36 (SF-36), is related to measured exercise capacity and metabolic efficiency in a cohort of healthy subjects from the Gothenburg area of Sweden. Individuals were invited to take part in the evaluation where HRQL was compared with the maximal power output expressed in Watts assessed during a standardized treadmill test with incremental work loads. Whole body respiratory gas exchanges (CO2/O2) were simultaneously measured. Estimate of metabolic efficiency was derived from oxygen uptake per Watt produced (ml O2/min/W) near maximal work. The health status profile in the current population largely agreed with normative data from an age- and gender-matched reference group, although some measured scores were slightly better than reference scores. Males and females had a similar relationship between energy cost (ml O2/min) for production of maximal work (W), while the regressions for maximal exercise power and age were significantly different between males and females (p < 0.01). The overall metabolic efficiency was the same in individuals between 40 and 74 years of age (10.4 +/- 0.07 ml O2/min/ Watt). Maximal exercise power was only related to the SF-36 subscale physical functioning (PF), but unrelated to other physical subscales such as role limitations due to physical problems, good general health and vitality. There was also a discrepancy between measured maximal power and PF in many subjects, particularly in males who experienced either intact or severely reduced PF. Our results demonstrate that simultaneous measurements of self-reported and objective measures of PF should add a more integrated view for evaluation of therapeutic effectiveness, since the overall correlation was poor between objective and subjective scores among individuals.

  2. Effect of gear ratio on peak power and time to peak power in BMX cyclists.

    PubMed

    Rylands, Lee P; Roberts, Simon J; Hurst, Howard T

    2017-03-01

    The aim of this study was to ascertain if gear ratio selection would have an effect on peak power and time to peak power production in elite Bicycle Motocross (BMX) cyclists. Eight male elite BMX riders volunteered for the study. Each rider performed three, 10-s maximal sprints on an Olympic standard indoor BMX track. The riders' bicycles were fitted with a portable SRM power meter. Each rider performed the three sprints using gear ratios of 41/16, 43/16 and 45/16 tooth. The results from the 41/16 and 45/16 gear ratios were compared to the current standard 43/16 gear ratio. Statistically, significant differences were found between the gear ratios for peak power (F(2,14) = 6.448; p = .010) and peak torque (F(2,14) = 4.777; p = .026), but no significant difference was found for time to peak power (F(2,14) = 0.200; p = .821). When comparing gear ratios, the results showed a 45/16 gear ratio elicited the highest peak power,1658 ± 221 W, compared to 1436 ± 129 W and 1380 ± 56 W, for the 43/16 and 41/16 ratios, respectively. The time to peak power showed a 41/16 tooth gear ratio attained peak power in -0.01 s and a 45/16 in 0.22 s compared to the 43/16. The findings of this study suggest that gear ratio choice has a significant effect on peak power production, though time to peak power output is not significantly affected. Therefore, selecting a higher gear ratio results in riders attaining higher power outputs without reducing their start time.

  3. Increase in Jumping Height Associated with Maximal Effort Vertical Depth Jumps.

    ERIC Educational Resources Information Center

    Bedi, John F.; And Others

    1987-01-01

    In order to assess if there existed a statistically significant increase in jumping performance when dropping from different heights, 32 males, aged 19 to 26, performed a series of maximal effort vertical jumps after dropping from eight heights onto a force plate. Results are analyzed. (Author/MT)

  4. Power Maximization Control of Variable Speed Wind Generation System Using Permanent Magnet Synchronous Generator

    NASA Astrophysics Data System (ADS)

    Morimoto, Shigeo; Nakamura, Tomohiko; Takeda, Yoji

    This paper proposes the sensorless output power maximization control of the wind generation system. A permanent magnet synchronous generator (PMSG) is used as a variable speed generator in the proposed system. The generator torque is suitably controlled according to the generator speed and thus the power from a wind turbine settles down on the maximum power point by the proposed MPPT control method, where the information of wind velocity is not required. Moreover, the maximum available generated power is obtained by the optimum current vector control. The current vector of PMSG is optimally controlled according to the generator speed and the required torque in order to minimize the losses of PMSG considering the voltage and current constraints. The proposed wind power generation system can be achieved without mechanical sensors such as a wind velocity detector and a position sensor. Several experimental results show the effectiveness of the proposed control method.

  5. Change in power output across a high-repetition set of bench throws and jump squats in highly trained athletes.

    PubMed

    Baker, Daniel G; Newton, Robert U

    2007-11-01

    Athletes experienced in maximal-power and power-endurance training performed 1 set of 2 common power training exercises in an effort to determine the effects of moderately high repetitions upon power output levels throughout the set. Twenty-four and 15 athletes, respectively, performed a set of 10 repetitions in both the bench throw (BT P60) and jump squat exercise (JS P60) with a resistance of 60 kg. For both exercises, power output was highest on either the second (JS P60) or the third repetition (BT P60) and was then maintained until the fifth repetition. Significant declines in power output occurred from the sixth repetition onwards until the 10th repetition (11.2% for BT P60 and 5% for JS P60 by the 10th repetition). These findings suggest that athletes attempting to increase maximal power limit their repetitions to 2 to 5 when using resistances of 35 to 45% 1RM in these exercises.

  6. A comparison of physiological and anthropometric characteristics among playing positions in junior rugby league players

    PubMed Central

    Gabbett, T

    2005-01-01

    Objectives: To compare the physiological and anthropometric characteristics of specific playing positions and positional playing groups in junior rugby league players. Methods: Two hundred and forty junior rugby league players underwent measurements of standard anthropometry (body mass, height, sum of four skinfolds), muscular power (vertical jump), speed (10, 20, and 40 m sprint), agility (L run), and estimated maximal aerobic power (multi-stage fitness test) during the competitive phase of the season, after players had obtained a degree of match fitness. Results: Props were significantly (p<0.05) taller, heavier, and had greater skinfold thickness than all other positions. The halfback and centre positions were faster than props over 40 m. Halfbacks had significantly (p<0.05) greater estimated maximal aerobic power than props. When data were analysed according to positional similarities, it was found that the props positional group had lower 20 and 40 m speed, agility, and estimated maximal aerobic power than the hookers and halves and outside backs positional groups. Differences in the physiological and anthropometric characteristics of other individual playing positions and positional playing groups were uncommon. Conclusions: The results of this study demonstrate that few physiological and anthropometric differences exist among individual playing positions in junior rugby league players, although props are taller, heavier, have greater skinfold thickness, lower 20 and 40 m speed, agility, and estimated maximal aerobic power than other positional playing groups. These findings provide normative data and realistic performance standards for junior rugby league players competing in specific individual positions and positional playing groups. PMID:16118309

  7. A Unique Power System For The ISS Fluids And Combustion Facility

    NASA Technical Reports Server (NTRS)

    Fox, David A.; Poljak, Mark D.

    2001-01-01

    Unique power control technology has been incorporated into an electrical power control unit (EPCU) for the Fluids and Combustion Facility (FCF). The objective is to maximize science throughput by providing a flexible power system that is easily reconfigured by the science payload. Electrical power is at a premium on the International Space Station (ISS). The EPCU utilizes advanced power management techniques to maximize the power available to the FCF experiments. The EPCU architecture enables dynamic allocation of power from two ISS power channels for experiments. Because of the unique flexible remote power controller (FRPC) design, power channels can be paralleled while maintaining balanced load sharing between the channels. With an integrated and redundant architecture, the EPCU can tolerate multiple faults and still maintain FCF operation. It is important to take full advantage of the EPCU functionality. The EPCU acts as a buffer between the experimenter and the ISS power system with all its complex requirements. However, FCF science payload developers will still need to follow guidelines when designing the FCF payload power system. This is necessary to ensure power system stability, fault coordination, electromagnetic compatibility, and maximum use of available power for gathering scientific data.

  8. Maximization of the connectivity repertoire as a statistical principle governing the shapes of dendritic arbors

    PubMed Central

    Wen, Quan; Stepanyants, Armen; Elston, Guy N.; Grosberg, Alexander Y.; Chklovskii, Dmitri B.

    2009-01-01

    The shapes of dendritic arbors are fascinating and important, yet the principles underlying these complex and diverse structures remain unclear. Here, we analyzed basal dendritic arbors of 2,171 pyramidal neurons sampled from mammalian brains and discovered 3 statistical properties: the dendritic arbor size scales with the total dendritic length, the spatial correlation of dendritic branches within an arbor has a universal functional form, and small parts of an arbor are self-similar. We proposed that these properties result from maximizing the repertoire of possible connectivity patterns between dendrites and surrounding axons while keeping the cost of dendrites low. We solved this optimization problem by drawing an analogy with maximization of the entropy for a given energy in statistical physics. The solution is consistent with the above observations and predicts scaling relations that can be tested experimentally. In addition, our theory explains why dendritic branches of pyramidal cells are distributed more sparsely than those of Purkinje cells. Our results represent a step toward a unifying view of the relationship between neuronal morphology and function. PMID:19622738

  9. Tailless Vectored Fighters Theory. Laboratory and Flight Tests, Including Vectorable Inlets/Nozzles and Tailless Flying Models vs. Pilot’s Tolerances Affecting Maximum Post-Stall Vectoring Agility.

    DTIC Science & Technology

    1991-07-01

    nose bodyj Top view of velocity probe PropllerRotating shaft ’V Generator Aerodynamic shape like a small elevator RPV’s attitude Irrespctiveduring...28 Part It: Maximizing Thrust-Vectoring Control Power and Agility Metrics ............ 29 Laboratory & Flight...8217Ideal Standards’ - Ba- ror maximizing PST-TV-aglilty/rIlght-control power , iI - Extracting new TV-potentials to further reduce any righter’s optical

  10. Energy Efficiency Maximization for WSNs with Simultaneous Wireless Information and Power Transfer

    PubMed Central

    Yu, Hongyan; Zhang, Yongqiang; Yang, Yuanyuan; Ji, Luyue

    2017-01-01

    Recently, the simultaneous wireless information and power transfer (SWIPT) technique has been regarded as a promising approach to enhance performance of wireless sensor networks with limited energy supply. However, from a green communication perspective, energy efficiency optimization for SWIPT system design has not been investigated in Wireless Rechargeable Sensor Networks (WRSNs). In this paper, we consider the tradeoffs between energy efficiency and three factors including spectral efficiency, the transmit power and outage target rate for two different modes, i.e., power splitting (PS) and time switching modes (TS), at the receiver. Moreover, we formulate the energy efficiency maximization problem subject to the constraints of minimum Quality of Service (QoS), minimum harvested energy and maximum transmission power as non-convex optimization problem. In particular, we focus on optimizing power control and power allocation policy in PS and TS modes to maximize energy efficiency of data transmission. For PS and TS modes, we propose the corresponding algorithm to characterize a non-convex optimization problem that takes into account the circuit power consumption and the harvested energy. By exploiting nonlinear fractional programming and Lagrangian dual decomposition, we propose suboptimal iterative algorithms to obtain the solutions of non-convex optimization problems. Furthermore, we derive the outage probability and effective throughput from the scenarios that the transmitter does not or partially know the channel state information (CSI) of the receiver. Simulation results illustrate that the proposed optimal iterative algorithm can achieve optimal solutions within a small number of iterations and various tradeoffs between energy efficiency and spectral efficiency, transmit power and outage target rate, respectively. PMID:28820496

  11. Energy Efficiency Maximization for WSNs with Simultaneous Wireless Information and Power Transfer.

    PubMed

    Yu, Hongyan; Zhang, Yongqiang; Guo, Songtao; Yang, Yuanyuan; Ji, Luyue

    2017-08-18

    Recently, the simultaneous wireless information and power transfer (SWIPT) technique has been regarded as a promising approach to enhance performance of wireless sensor networks with limited energy supply. However, from a green communication perspective, energy efficiency optimization for SWIPT system design has not been investigated in Wireless Rechargeable Sensor Networks (WRSNs). In this paper, we consider the tradeoffs between energy efficiency and three factors including spectral efficiency, the transmit power and outage target rate for two different modes, i.e., power splitting (PS) and time switching modes (TS), at the receiver. Moreover, we formulate the energy efficiency maximization problem subject to the constraints of minimum Quality of Service (QoS), minimum harvested energy and maximum transmission power as non-convex optimization problem. In particular, we focus on optimizing power control and power allocation policy in PS and TS modes to maximize energy efficiency of data transmission. For PS and TS modes, we propose the corresponding algorithm to characterize a non-convex optimization problem that takes into account the circuit power consumption and the harvested energy. By exploiting nonlinear fractional programming and Lagrangian dual decomposition, we propose suboptimal iterative algorithms to obtain the solutions of non-convex optimization problems. Furthermore, we derive the outage probability and effective throughput from the scenarios that the transmitter does not or partially know the channel state information (CSI) of the receiver. Simulation results illustrate that the proposed optimal iterative algorithm can achieve optimal solutions within a small number of iterations and various tradeoffs between energy efficiency and spectral efficiency, transmit power and outage target rate, respectively.

  12. Neuromuscular Taping Application in Counter Movement Jump: Biomechanical Insight in a Group of Healthy Basketball Players.

    PubMed

    Marcolin, Giuseppe; Buriani, Alessandro; Giacomelli, Andrea; Blow, David; Grigoletto, Davide; Gesi, Marco

    2017-06-24

    Kinesiologic elastic tape is widely used for both clinical and sport applications although its efficacy in enhancing agonistic performance is still controversial. Aim of the study was to verify in a group of healthy basketball players whether a neuromuscular taping application (NMT) on ankle and knee joints could affect the kinematic and the kinetic parameters of the jump, either by enhancing or inhibiting the functional performance. Fourteen healthy male basketball players without any ongoing pathologies at upper limbs, lower limbs and trunk volunteered in the study. They randomly performed 2 sets of 5 counter movement jumps (CMJ) with and without application of Kinesiologic tape. The best 3 jumps of each set were considered for the analysis. The Kinematics parameters analyzed were: knees maximal flexion and ankles maximal dorsiflexion during the push off phase, jump height and take off velocity. Vertical ground reaction force and maximal power expressed in the push off phase of the jump were also investigated. The NMT application in both knees and ankles showed no statistically significant differences in the kinematic and kinetic parameters and did not interfere with the CMJ performance. Bilateral NMT application in the group of healthy male basketball players did not change kinematics and kinetics jump parameters, thus suggesting that its routine use should have no negative effect on functional performance. Similarly, the combined application of the tape on both knees and ankles did not affect in either way jump performance.

  13. Neuromuscular Taping Application in Counter Movement Jump: Biomechanical Insight in a Group of Healthy Basketball Players

    PubMed Central

    Marcolin, Giuseppe; Buriani, Alessandro; Giacomelli, Andrea; Blow, David; Grigoletto, Davide; Gesi, Marco

    2017-01-01

    Kinesiologic elastic tape is widely used for both clinical and sport applications although its efficacy in enhancing agonistic performance is still controversial. Aim of the study was to verify in a group of healthy basketball players whether a neuromuscular taping application (NMT) on ankle and knee joints could affect the kinematic and the kinetic parameters of the jump, either by enhancing or inhibiting the functional performance. Fourteen healthy male basketball players without any ongoing pathologies at upper limbs, lower limbs and trunk volunteered in the study. They randomly performed 2 sets of 5 counter movement jumps (CMJ) with and without application of Kinesiologic tape. The best 3 jumps of each set were considered for the analysis. The Kinematics parameters analyzed were: knees maximal flexion and ankles maximal dorsiflexion during the push off phase, jump height and take off velocity. Vertical ground reaction force and maximal power expressed in the push off phase of the jump were also investigated. The NMT application in both knees and ankles showed no statistically significant differences in the kinematic and kinetic parameters and did not interfere with the CMJ performance. Bilateral NMT application in the group of healthy male basketball players did not change kinematics and kinetics jump parameters, thus suggesting that its routine use should have no negative effect on functional performance. Similarly, the combined application of the tape on both knees and ankles did not affect in either way jump performance. PMID:28713536

  14. Agreement of Power Measures between Garmin Vector and SRM Cycle Power Meters

    ERIC Educational Resources Information Center

    Novak, Andrew R.; Dascombe, Benjamin J.

    2016-01-01

    This study aimed to determine if the Garmin Vector (Schaffhausen, Switzerland) power meter produced acceptable measures when compared with the Schoberer Rad Messetechnik (SRM; Julich, Germany) power meter across a range of high-intensity efforts. Twenty-one well-trained cyclists completed power profiles (seven maximal mean efforts between 5 and…

  15. Across-cohort QC analyses of GWAS summary statistics from complex traits.

    PubMed

    Chen, Guo-Bo; Lee, Sang Hong; Robinson, Matthew R; Trzaskowski, Maciej; Zhu, Zhi-Xiang; Winkler, Thomas W; Day, Felix R; Croteau-Chonka, Damien C; Wood, Andrew R; Locke, Adam E; Kutalik, Zoltán; Loos, Ruth J F; Frayling, Timothy M; Hirschhorn, Joel N; Yang, Jian; Wray, Naomi R; Visscher, Peter M

    2016-01-01

    Genome-wide association studies (GWASs) have been successful in discovering SNP trait associations for many quantitative traits and common diseases. Typically, the effect sizes of SNP alleles are very small and this requires large genome-wide association meta-analyses (GWAMAs) to maximize statistical power. A trend towards ever-larger GWAMA is likely to continue, yet dealing with summary statistics from hundreds of cohorts increases logistical and quality control problems, including unknown sample overlap, and these can lead to both false positive and false negative findings. In this study, we propose four metrics and visualization tools for GWAMA, using summary statistics from cohort-level GWASs. We propose methods to examine the concordance between demographic information, and summary statistics and methods to investigate sample overlap. (I) We use the population genetics F st statistic to verify the genetic origin of each cohort and their geographic location, and demonstrate using GWAMA data from the GIANT Consortium that geographic locations of cohorts can be recovered and outlier cohorts can be detected. (II) We conduct principal component analysis based on reported allele frequencies, and are able to recover the ancestral information for each cohort. (III) We propose a new statistic that uses the reported allelic effect sizes and their standard errors to identify significant sample overlap or heterogeneity between pairs of cohorts. (IV) To quantify unknown sample overlap across all pairs of cohorts, we propose a method that uses randomly generated genetic predictors that does not require the sharing of individual-level genotype data and does not breach individual privacy.

  16. Across-cohort QC analyses of GWAS summary statistics from complex traits

    PubMed Central

    Chen, Guo-Bo; Lee, Sang Hong; Robinson, Matthew R; Trzaskowski, Maciej; Zhu, Zhi-Xiang; Winkler, Thomas W; Day, Felix R; Croteau-Chonka, Damien C; Wood, Andrew R; Locke, Adam E; Kutalik, Zoltán; Loos, Ruth J F; Frayling, Timothy M; Hirschhorn, Joel N; Yang, Jian; Wray, Naomi R; Visscher, Peter M

    2017-01-01

    Genome-wide association studies (GWASs) have been successful in discovering SNP trait associations for many quantitative traits and common diseases. Typically, the effect sizes of SNP alleles are very small and this requires large genome-wide association meta-analyses (GWAMAs) to maximize statistical power. A trend towards ever-larger GWAMA is likely to continue, yet dealing with summary statistics from hundreds of cohorts increases logistical and quality control problems, including unknown sample overlap, and these can lead to both false positive and false negative findings. In this study, we propose four metrics and visualization tools for GWAMA, using summary statistics from cohort-level GWASs. We propose methods to examine the concordance between demographic information, and summary statistics and methods to investigate sample overlap. (I) We use the population genetics Fst statistic to verify the genetic origin of each cohort and their geographic location, and demonstrate using GWAMA data from the GIANT Consortium that geographic locations of cohorts can be recovered and outlier cohorts can be detected. (II) We conduct principal component analysis based on reported allele frequencies, and are able to recover the ancestral information for each cohort. (III) We propose a new statistic that uses the reported allelic effect sizes and their standard errors to identify significant sample overlap or heterogeneity between pairs of cohorts. (IV) To quantify unknown sample overlap across all pairs of cohorts, we propose a method that uses randomly generated genetic predictors that does not require the sharing of individual-level genotype data and does not breach individual privacy. PMID:27552965

  17. Solar Flare Super-Events: When they Can Occur and the Energy Limits of their Realization

    NASA Astrophysics Data System (ADS)

    Ishkov, Vitaly N.

    2015-03-01

    For the successful development of terrestrial civilization it is necessary to estimate the space factors, including phenomena on Sun, which can ruin it or cause such catastrophic loss, that the restoration to the initial level can take unacceptably long time. Super-powerful solar flares are the only such phenomena. Therefore an attempt is undertaken to estimate the possibility of such super-event occurrence at this stage of our star evolution. Since solar flare events are the consequence of the newly emerging magnetic fluxes interacting with the already existing magnetic fields of active regions, are investigated the observed cases which lead to the realization of such super-events. From the observations of the maximal magnetic fluxes during the period of reliable solar observations, the conclusion is made that the super- extreme solar flares cannot significantly exceed the most powerful solar flares which have already been observed. On the statistics of the reliable solar cycles the sunspot groups, in which occurred the most powerful solar super-events (August- September 1859 - solar cycle 10; June 1991 - SC 22; October-November 2003 - SC 23) appeared in the periods of the solar magnetic field reorganization between the epochs of "increased" and "lowered" solar activity.

  18. Fatigue during maximal sprint cycling: unique role of cumulative contraction cycles.

    PubMed

    Tomas, Aleksandar; Ross, Emma Z; Martin, James C

    2010-07-01

    Maximal cycling power has been reported to decrease more rapidly when performed with increased pedaling rates. Increasing pedaling rate imposes two constraints on the neuromuscular system: 1) decreased time for muscle excitation and relaxation and 2) increased muscle shortening velocity. Using two crank lengths allows the effects of time and shortening velocity to be evaluated separately. We conducted this investigation to determine whether the time available for excitation and relaxation or the muscle shortening velocity was mainly responsible for the increased rate of fatigue previously observed with increased pedaling rates and to evaluate the influence of other possible fatiguing constraints. Seven trained cyclists performed 30-s maximal isokinetic cycling trials using two crank lengths: 120 and 220 mm. Pedaling rate was optimized for maximum power for each crank length: 135 rpm for the 120-mm cranks (1.7 m x s(-1) pedal speed) and 109 rpm for the 220-mm cranks (2.5 m x s(-1) pedal speed). Power was recorded with an SRM power meter. Crank length did not affect peak power: 999 +/- 276 W for the 120-mm crank versus 1001 +/- 289 W for the 220-mm crank. Fatigue index was greater (58.6% +/- 3.7% vs 52.4% +/- 4.8%, P < 0.01), and total work was less (20.0 +/- 1.8 vs 21.4 +/- 2.0 kJ, P < 0.01) with the higher pedaling rate-shorter crank condition. Regression analyses indicated that the power for the two conditions was most highly related to cumulative work (r2 = 0.94) and to cumulative cycles (r2 = 0.99). These results support previous findings and confirm that pedaling rate, rather than pedal speed, was the main factor influencing fatigue. Our novel result was that power decreased by a similar increment with each crank revolution for the two conditions, indicating that each maximal muscular contraction induced a similar amount of fatigue.

  19. Cardio-pulmonary responses to incremental eccentric and concentric cycling tests to task failure.

    PubMed

    Lipski, Marcin; Abbiss, Chris R; Nosaka, Kazunori

    2018-05-01

    This study compared cardio-pulmonary responses between incremental concentric and eccentric cycling tests, and examined factors affecting the maximal eccentric cycling capacity. On separate days, nine men and two women (32.6 ± 9.4 years) performed an upright seated concentric (CON) and an eccentric (ECC) cycling test, which started at 75 W and increased 25 W min -1 until task failure. Gas exchange, heart rate (HR) and power output were continuously recorded during the tests. Participants also performed maximal voluntary contractions of the quadriceps (MVC), squat and countermovement jumps. Peak power output was 53% greater (P < 0.001, g = 1.77) for ECC (449 ± 115 W) than CON (294 ± 61 W), but peak oxygen consumption was 43% lower (P < 0.001, g = 2.18) for ECC (30.6 ± 5.6 ml kg min -1 ) than CON (43.9 ± 6.9 ml kg min -1 ). Maximal HR was not different between ECC (175 ± 20 bpm) and CON (182 ± 13 bpm), but the increase in HR relative to oxygen consumption was 33% greater (P = 0.01) during ECC than CON. Moderate to strong correlations (P < 0.05) were observed between ECC peak power output and CON peak power (r = 0.84), peak oxygen consumption (r = 0.54) and MVC (r = 0.53), while no significant relationships were observed between ECC peak power output and squat as well as countermovement jump heights. Unexpectedly, maximal HR was similar between CON and ECC. Although ECC power output can be predicted from CON peak power output, an incremental eccentric cycling test performed after 3-6 familiarisation sessions may be useful in programming ECC training with healthy and accustomed individuals.

  20. The efficacy of incorporating partial squats in maximal strength training.

    PubMed

    Bazyler, Caleb D; Sato, Kimitake; Wassinger, Craig A; Lamont, Hugh S; Stone, Michael H

    2014-11-01

    The purpose of our study was to examine the effects of 2 different training methods on dynamic and isometric measures of maximal strength. Seventeen recreationally trained men (1 repetition maximum [1RM] squat: 146.9 ± 22.4 kg) were assigned to 2 groups: full range of motion (ROM) squat (F) and full ROM with partial ROM squat (FP) for the 7-week training intervention. Repeated measures analysis of variance revealed that there was a statistically significant group-by-time interaction for impulse scaled at 50, 90, and 250 milliseconds at 90° of knee flexion and rate of force development at 200 milliseconds with 120° of knee flexion (p ≤ 0.05). There was also a statistically significant time effect (p ≤ 0.05) for the 1RM squat, 1RM partial squat, isometric squat peak force allometrically scaled (IPFa) 90°, IPFa 120°, and impulse allometrically scaled at 50, 90, 200, and 250 milliseconds at 90° and 120° of knee flexion. Additionally, the FP group achieved statistically larger relative training intensities (%1RM) during the final 3 weeks of training (p ≤ 0.05). There was a trend for FP to improve over F in 1RM squat (+3.1%, d = 0.53 vs. 0.32), 1RM partial squat (+4.7%, d = 0.95 vs. 0.69), IPFa 120° (+5.7%, d = 0.52 vs. 0.12), and impulse scaled at 50, 90, 200, and 250 milliseconds at 90° (+6.3 to 13.2%, d = 0.50-1.01 vs. 0.30-0.57) and 120° (+3.4 to 16.8%, d = 0.45-1.11 vs. 0.08-0.37). These larger effect sizes in the FP group can likely be explained their ability to train at larger relative training intensities during the final 3 weeks of training resulting in superior training adaptations. Our findings suggest that partial ROM squats in conjunction with full ROM squats may be an effective training method for improving maximal strength and early force-time curve characteristics in men with previous strength training experience. Practically, partial squats may be beneficial for strength and power athletes during a strength-speed mesocycle while peaking for competition.

  1. Maximal physical work performance with European standard based fire-protective clothing system and equipment in relation to individual characteristics.

    PubMed

    Louhevaara, V; Ilmarinen, R; Griefahn, B; Künemund, C; Mäkinen, H

    1995-01-01

    Every fire fighter needs to wear fire-protective clothing and a self-contained breathing apparatus (SCBA) several times a year while carrying out various fire-fighting and rescue operations in hazardous work environments. The aim of the present study was to quantify the effects of a multilayer turnout suit designed to fulfil European standard EN 469 used over standardized (Nordic) clothing and with SCBA (total mass 25.9 kg) on maximal physical work performance, and to evaluate the relationship between individual characteristics and power output with the fire-protective clothing system and SCBA. The subjects were 12 healthy firemen aged 26-46 years. The range of their body mass, body fat and maximal oxygen consumption was 69-101 kg, 10-20% and 2.70-5.86 l.min-1, respectively. The maximal tests without (control) and with the fire-protective clothing system and SCBA were carried out on a treadmill in a thermoneutral environment. When compared to the control test, the decrease in the maximal power output in terms of maximal working time and walking speed averaged 25% (P < 0.001) varying from 18% to 34% with the fire-protective clothing system and SCBA. At maximum, no significant differences were found in pulmonary ventilation, absolute oxygen consumption, the respiratory exchange ratio, heart rate, systolic blood pressure, the rate-pressure product, mechanical efficiency, and the rating of perceived exertion between the tests with and without the fire-protective clothing system and SCBA. The reduction of the power output was related to the extra mass of the fire protective clothing and SCBA.(ABSTRACT TRUNCATED AT 250 WORDS)

  2. Cournot games with network effects for electric power markets

    NASA Astrophysics Data System (ADS)

    Spezia, Carl John

    The electric utility industry is moving from regulated monopolies with protected service areas to an open market with many wholesale suppliers competing for consumer load. This market is typically modeled by a Cournot game oligopoly where suppliers compete by selecting profit maximizing quantities. The classical Cournot model can produce multiple solutions when the problem includes typical power system constraints. This work presents a mathematical programming formulation of oligopoly that produces unique solutions when constraints limit the supplier outputs. The formulation casts the game as a supply maximization problem with power system physical limits and supplier incremental profit functions as constraints. The formulation gives Cournot solutions identical to other commonly used algorithms when suppliers operate within the constraints. Numerical examples demonstrate the feasibility of the theory. The results show that the maximization formulation will give system operators more transmission capacity when compared to the actions of suppliers in a classical constrained Cournot game. The results also show that the profitability of suppliers in constrained networks depends on their location relative to the consumers' load concentration.

  3. Executive function moderates the role of muscular fitness in determining functional mobility in older adults.

    PubMed

    Forte, Roberta; Pesce, Caterina; Leite, Joao Costa; De Vito, Giuseppe; Gibney, Eileen R; Tomporowski, Phillip D; Boreham, Colin A G

    2013-06-01

    Both physical and cognitive factors are known to independently predict functional mobility in older people. However, the combined predictive value of both physical fitness and cognitive factors on functional mobility has been less investigated. The aim of the present study was to assess if cognitive executive functions moderate the role of physical fitness in determining functional mobility of older individuals. Fifty-seven 65- to 75-year-old healthy participants performed tests of functional mobility (habitual and maximal walking speed, maximal walking speed while picking up objects/stepping over obstacles), physical fitness (peak power, knee extensors torque, back/lower limb flexibility, aerobic fitness), and executive function (inhibition and cognitive flexibility). Maximal walking speeds were predicted by physical fitness parameters and their interaction with cognitive factors. Knee extensor torque emerged as the main predictor of all tested locomotor performances at maximal speed. The effect of peak power and back/lower limb flexibility was moderated by executive functions. In particular, inhibition and cognitive flexibility differed in the way in which they moderate the role of fitness. High levels of cognitive flexibility seem necessary to take advantage of leg power for walking at maximal speed. In contrast, high levels of inhibitory capacity seem to compensate for low levels of back/lower limb flexibility when picking up movements are added to a locomotor task. These findings may have important practical implications for the design and implementation of multi-component training programs aimed at optimizing functional abilities in older adults.

  4. Evaluation of reconstruction techniques in regional cerebral blood flow SPECT using trade-off plots: a Monte Carlo study.

    PubMed

    Olsson, Anna; Arlig, Asa; Carlsson, Gudrun Alm; Gustafsson, Agnetha

    2007-09-01

    The image quality of single photon emission computed tomography (SPECT) depends on the reconstruction algorithm used. The purpose of the present study was to evaluate parameters in ordered subset expectation maximization (OSEM) and to compare systematically with filtered back-projection (FBP) for reconstruction of regional cerebral blood flow (rCBF) SPECT, incorporating attenuation and scatter correction. The evaluation was based on the trade-off between contrast recovery and statistical noise using different sizes of subsets, number of iterations and filter parameters. Monte Carlo simulated SPECT studies of a digital human brain phantom were used. The contrast recovery was calculated as measured contrast divided by true contrast. Statistical noise in the reconstructed images was calculated as the coefficient of variation in pixel values. A constant contrast level was reached above 195 equivalent maximum likelihood expectation maximization iterations. The choice of subset size was not crucial as long as there were > or = 2 projections per subset. The OSEM reconstruction was found to give 5-14% higher contrast recovery than FBP for all clinically relevant noise levels in rCBF SPECT. The Butterworth filter, power 6, achieved the highest stable contrast recovery level at all clinically relevant noise levels. The cut-off frequency should be chosen according to the noise level accepted in the image. Trade-off plots are shown to be a practical way of deciding the number of iterations and subset size for the OSEM reconstruction and can be used for other examination types in nuclear medicine.

  5. Effect of 8 weeks of free-weight and machine-based strength training on strength and power performance

    PubMed Central

    Wirth, Klaus; Hartmann, Hagen; Sander, Andre; Mickel, Christoph

    2016-01-01

    Abstract The aim of this study was to evaluate the effectiveness of free-weight and machine-based exercises to increase different strength and speed-strength variables. One hundred twenty male participants (age: 23.8 ± 2.5 years; body height: 181.0 ± 6.8 cm; body mass: 80.2 ± 8.9 kg) joined the study. The 2 experimental groups completed an 8 week periodized strength training program that included 2 training sessions per week. The exercises that were used in the strength training programs were the parallel barbell squat and the leg press. Before and after the training period, the 1-repetition-maximum in the barbell squat and the leg press, the squat jump, the countermovement jump and unilateral isometric force (maximal isometric force and the rate of force development) were evaluated. To compare each group pre vs. post-intervention, analysis of variance with repeated measures and Scheffé post-hoc tests were used. The leg press group increased their 1-repetition-maximum significantly (p < 0.001), while in the squat group such variables as 1-repetition-maximum, the squat jump and the countermovement jump increased significantly (p < 0.001). The maximal isometric force showed no statistically significant result for the repeated measures factor, while the rate of force development of the squat group even showed a statistically significant decrease. Differences between the 2 experimental groups were detected for the squat jump and the countermovement jump. In comparison with the leg press, the squat might be a better strength training exercise for the development of jump performance. PMID:28149424

  6. Effect of 8 weeks of free-weight and machine-based strength training on strength and power performance.

    PubMed

    Wirth, Klaus; Keiner, Michael; Hartmann, Hagen; Sander, Andre; Mickel, Christoph

    2016-12-01

    The aim of this study was to evaluate the effectiveness of free-weight and machine-based exercises to increase different strength and speed-strength variables. One hundred twenty male participants (age: 23.8 ± 2.5 years; body height: 181.0 ± 6.8 cm; body mass: 80.2 ± 8.9 kg) joined the study. The 2 experimental groups completed an 8 week periodized strength training program that included 2 training sessions per week. The exercises that were used in the strength training programs were the parallel barbell squat and the leg press. Before and after the training period, the 1-repetition-maximum in the barbell squat and the leg press, the squat jump, the countermovement jump and unilateral isometric force (maximal isometric force and the rate of force development) were evaluated. To compare each group pre vs. post-intervention, analysis of variance with repeated measures and Scheffé post-hoc tests were used. The leg press group increased their 1-repetition-maximum significantly (p < 0.001), while in the squat group such variables as 1-repetition-maximum, the squat jump and the countermovement jump increased significantly (p < 0.001). The maximal isometric force showed no statistically significant result for the repeated measures factor, while the rate of force development of the squat group even showed a statistically significant decrease. Differences between the 2 experimental groups were detected for the squat jump and the countermovement jump. In comparison with the leg press, the squat might be a better strength training exercise for the development of jump performance.

  7. Effect of active warm-up duration on morning short-term maximal performance during Ramadan.

    PubMed

    Baklouti, Hana; Chtourou, Hamdi; Aloui, Asma; Chaouachi, Anis; Souissi, Nizar

    2015-01-01

    Purpose To examine the effect of active warm-up duration on short-term maximal performance assessed during Ramadan in the morning. Methods Twelve healthy active men performed four Wingate tests for measurement of peak power and mean power before and during Ramadan at 09:00 a.m. The tests were performed on separate days, after either a 5-min or a 15-min warm-up. The warm-up consisted in pedaling at 50% of the power output obtained at the last stage of a submaximal multistage cycling test. Oral temperature was measured at rest and after warming-up. Furthermore, ratings of perceived exertion were obtained immediately after the Wingate test. Results Oral temperature was higher after the 15-min warm-up than the 5-min warm-up throughout the study. Moreover, peak power and mean power were higher after the 15-min warm-up than the 5-min warm-up before Ramadan. However, during Ramadan, there was no significant difference between the two warm-up durations. In addition, ratings of perceived exertion were higher after the 15-min warm-up than the 5-min warm-up only during Ramadan. Conclusions There is no need to prolong the warm-up period before short-term maximal exercise performed during Ramadan in the morning.

  8. Effect of active warm-up duration on morning short-term maximal performance during Ramadan.

    PubMed

    Baklouti, Hana; Chtourou, Hamdi; Aloui, Asma; Chaouachi, Anis; Souissi, Nizar

    2015-01-01

    To examine the effect of active warm-up duration on short-term maximal performance assessed during Ramadan in the morning. Twelve healthy active men performed four Wingate tests for measurement of peak power and mean power before and during Ramadan at 09:00 a.m. The tests were performed on separate days, after either a 5-min or a 15-min warm-up. The warm-up consisted in pedaling at 50% of the power output obtained at the last stage of a submaximal multistage cycling test. Oral temperature was measured at rest and after warming-up. Furthermore, ratings of perceived exertion were obtained immediately after the Wingate test. Oral temperature was higher after the 15-min warm-up than the 5-min warm-up throughout the study. Moreover, peak power and mean power were higher after the 15-min warm-up than the 5-min warm-up before Ramadan. However, during Ramadan, there was no significant difference between the two warm-up durations. In addition, ratings of perceived exertion were higher after the 15-min warm-up than the 5-min warm-up only during Ramadan. There is no need to prolong the warm-up period before short-term maximal exercise performed during Ramadan in the morning.

  9. Effect of active warm-up duration on morning short-term maximal performance during Ramadan

    PubMed Central

    Baklouti, Hana; Chtourou, Hamdi; Aloui, Asma; Chaouachi, Anis; Souissi, Nizar

    2015-01-01

    Purpose To examine the effect of active warm-up duration on short-term maximal performance assessed during Ramadan in the morning. Methods Twelve healthy active men performed four Wingate tests for measurement of peak power and mean power before and during Ramadan at 09:00 a.m. The tests were performed on separate days, after either a 5-min or a 15-min warm-up. The warm-up consisted in pedaling at 50% of the power output obtained at the last stage of a submaximal multistage cycling test. Oral temperature was measured at rest and after warming-up. Furthermore, ratings of perceived exertion were obtained immediately after the Wingate test. Results Oral temperature was higher after the 15-min warm-up than the 5-min warm-up throughout the study. Moreover, peak power and mean power were higher after the 15-min warm-up than the 5-min warm-up before Ramadan. However, during Ramadan, there was no significant difference between the two warm-up durations. In addition, ratings of perceived exertion were higher after the 15-min warm-up than the 5-min warm-up only during Ramadan. Conclusions There is no need to prolong the warm-up period before short-term maximal exercise performed during Ramadan in the morning. PMID:25676856

  10. Modern Empirical Statistical Spectral Analysis.

    DTIC Science & Technology

    1980-05-01

    716-723. Akaike, H. (1977). On entropy maximization principle, Applications of Statistics, P.R. Krishnaiah , ed., North-Holland, Amsterdam, 27-41...by P. Krishnaiah , North Holland: Amsterdam, 283-295. Parzen, E. (1979). Forecasting and whitening filter estimation, TIMS Studies in the Management

  11. Optimal laser wavelength for efficient laser power converter operation over temperature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Höhn, O., E-mail: oliver.hoehn@ise.fraunhofer.de; Walker, A. W.; Bett, A. W.

    2016-06-13

    A temperature dependent modeling study is conducted on a GaAs laser power converter to identify the optimal incident laser wavelength for optical power transmission. Furthermore, the respective temperature dependent maximal conversion efficiencies in the radiative limit as well as in a practically achievable limit are presented. The model is based on the transfer matrix method coupled to a two-diode model, and is calibrated to experimental data of a GaAs photovoltaic device over laser irradiance and temperature. Since the laser wavelength does not strongly influence the open circuit voltage of the laser power converter, the optimal laser wavelength is determined tomore » be in the range where the external quantum efficiency is maximal, but weighted by the photon flux of the laser.« less

  12. Associations Between Measures of Balance and Lower-Extremity Muscle Strength/Power in Healthy Individuals Across the Lifespan: A Systematic Review and Meta-Analysis.

    PubMed

    Muehlbauer, Thomas; Gollhofer, Albert; Granacher, Urs

    2015-12-01

    It has frequently been reported that balance and lower-extremity muscle strength/power are associated with sports-related and everyday activities. Knowledge about the relationship between balance, strength, and power are important for the identification of at-risk individuals because deficits in these neuromuscular components are associated with an increased risk of sustaining injuries and falls. In addition, this knowledge is of high relevance for the development of specifically tailored health and skill-related exercise programs. The objectives of this systematic literature review and meta-analysis were to characterize and, if possible, quantify associations between variables of balance and lower-extremity muscle strength/power in healthy individuals across the lifespan. A computerized systematic literature search was performed in the electronic databases PubMed, Web of Science, and SPORTDiscus up to March 2015 to capture all relevant articles. A systematic approach was used to evaluate the 996 articles identified for initial review. Studies were included only if they investigated healthy individuals aged ≥6 years and tested at least one measure of static steady-state balance (e.g., center of pressure [CoP] displacement during one-legged stance), dynamic steady-state balance (e.g., gait speed), proactive balance (e.g., distance in the functional-reach-test), or reactive balance (e.g., CoP displacement during perturbed one-legged stance), and one measure of maximal strength (e.g., maximum voluntary contraction), explosive force (e.g., rate of force development), or muscle power (e.g., jump height). In total, 37 studies met the inclusionary criteria for review. The included studies were coded for the following criteria: age (i.e., children: 6-12 years, adolescents: 13-18 years, young adults: 19-44 years, middle-aged adults: 45-64 years, old adults: ≥65 years), sex (i.e., female, male), and test modality/outcome (i.e., test for the assessment of balance, strength, and power). Studies with athletes, patients, and/or people with diseases were excluded. Pearson's correlation coefficients were extracted, transformed (i.e., Fisher's z-transformed r z value), aggregated (i.e., weighted mean r z value), back-transformed to r values, classified according to their magnitude (i.e., small: r ≤ 0.69, medium: r ≤ 0.89, large: r ≥ 0.90), and, if possible, statistically compared. Heterogeneity between studies was assessed using I2 and Chi-squared (χ2) statistics. Three studies examined associations between balance and lower-extremity muscle strength/power in children, one study in adolescents, nine studies in young adults, three studies in middle-aged adults, and 23 studies in old adults. Overall, small-sized associations were found between variables of balance and lower-extremity muscle strength/power, irrespective of the age group considered. In addition, small-sized but significantly larger correlation coefficients were found between measures of dynamic steady-state balance and maximal strength in children (r = 0.57) compared with young (r = 0.09, z = 3.30, p = 0.001) and old adults (r = 0.35, z = 2.94, p = 0.002) as well as in old compared with young adults (z = 1.95, p = 0.03). Even though the reported results provided further insight into the associations between measures of balance and lower-extremity muscle strength/power, they did not allow us to deduce cause and effect relations. Further, the investigated associations could be biased by other variables such as joint flexibility, muscle mass, and/or auditory/visual acuity. Our systematic review and meta-analysis showed predominately small-sized correlations between measures of balance and lower-extremity muscle strength/power in children, adolescents, and young, middle-aged, and old adults. This indicates that these neuromuscular components are independent of each other and should therefore be tested and trained complementarily across the lifespan. Significantly larger but still small-sized associations were found between measures of dynamic steady-state balance and maximal strength in children compared with young and old adults as well as in old compared with young adults. These findings imply that age/maturation may have an impact on the association of selected components of balance and lower-extremity muscle strength.

  13. Extension of the lod score: the mod score.

    PubMed

    Clerget-Darpoux, F

    2001-01-01

    In 1955 Morton proposed the lod score method both for testing linkage between loci and for estimating the recombination fraction between them. If a disease is controlled by a gene at one of these loci, the lod score computation requires the prior specification of an underlying model that assigns the probabilities of genotypes from the observed phenotypes. To address the case of linkage studies for diseases with unknown mode of inheritance, we suggested (Clerget-Darpoux et al., 1986) extending the lod score function to a so-called mod score function. In this function, the variables are both the recombination fraction and the disease model parameters. Maximizing the mod score function over all these parameters amounts to maximizing the probability of marker data conditional on the disease status. Under the absence of linkage, the mod score conforms to a chi-square distribution, with extra degrees of freedom in comparison to the lod score function (MacLean et al., 1993). The mod score is asymptotically maximum for the true disease model (Clerget-Darpoux and Bonaïti-Pellié, 1992; Hodge and Elston, 1994). Consequently, the power to detect linkage through mod score will be highest when the space of models where the maximization is performed includes the true model. On the other hand, one must avoid overparametrization of the model space. For example, when the approach is applied to affected sibpairs, only two constrained disease model parameters should be used (Knapp et al., 1994) for the mod score maximization. It is also important to emphasize the existence of a strong correlation between the disease gene location and the disease model. Consequently, there is poor resolution of the location of the susceptibility locus when the disease model at this locus is unknown. Of course, this is true regardless of the statistics used. The mod score may also be applied in a candidate gene strategy to model the potential effect of this gene in the disease. Since, however, it ignores the information provided both by disease segregation and by linkage disequilibrium between the marker alleles and the functional disease alleles, its power of discrimination between genetic models is weak. The MASC method (Clerget-Darpoux et al., 1988) has been designed to address more efficiently the objectives of a candidate gene approach.

  14. Realworld maximum power point tracking simulation of PV system based on Fuzzy Logic control

    NASA Astrophysics Data System (ADS)

    Othman, Ahmed M.; El-arini, Mahdi M. M.; Ghitas, Ahmed; Fathy, Ahmed

    2012-12-01

    In the recent years, the solar energy becomes one of the most important alternative sources of electric energy, so it is important to improve the efficiency and reliability of the photovoltaic (PV) systems. Maximum power point tracking (MPPT) plays an important role in photovoltaic power systems because it maximize the power output from a PV system for a given set of conditions, and therefore maximize their array efficiency. This paper presents a maximum power point tracker (MPPT) using Fuzzy Logic theory for a PV system. The work is focused on the well known Perturb and Observe (P&O) algorithm and is compared to a designed fuzzy logic controller (FLC). The simulation work dealing with MPPT controller; a DC/DC Ćuk converter feeding a load is achieved. The results showed that the proposed Fuzzy Logic MPPT in the PV system is valid.

  15. Regulation control and energy management scheme for wireless power transfer

    DOEpatents

    Miller, John M.

    2015-12-29

    Power transfer rate at a charging facility can be maximized by employing a feedback scheme. The state of charge (SOC) and temperature of the regenerative energy storage system (RESS) pack of a vehicle is monitored to determine the load due to the RESS pack. An optimal frequency that cancels the imaginary component of the input impedance for the output signal from a grid converter is calculated from the load of the RESS pack, and a frequency offset f* is made to the nominal frequency f.sub.0 of the grid converter output based on the resonance frequency of a magnetically coupled circuit. The optimal frequency can maximize the efficiency of the power transfer. Further, an optimal grid converter duty ratio d* can be derived from the charge rate of the RESS pack. The grid converter duty ratio d* regulates wireless power transfer (WPT) power level.

  16. Quantifying and minimizing entropy generation in AMTEC cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hendricks, T.J.; Huang, C.

    1997-12-31

    Entropy generation in an AMTEC cell represents inherent power loss to the AMTEC cell. Minimizing cell entropy generation directly maximizes cell power generation and efficiency. An internal project is on-going at AMPS to identify, quantify and minimize entropy generation mechanisms within an AMTEC cell, with the goal of determining cost-effective design approaches for maximizing AMTEC cell power generation. Various entropy generation mechanisms have been identified and quantified. The project has investigated several cell design techniques in a solar-driven AMTEC system to minimize cell entropy generation and produce maximum power cell designs. In many cases, various sources of entropy generation aremore » interrelated such that minimizing entropy generation requires cell and system design optimization. Some of the tradeoffs between various entropy generation mechanisms are quantified and explained and their implications on cell design are discussed. The relationship between AMTEC cell power and efficiency and entropy generation is presented and discussed.« less

  17. Gait analysis in patients operated on for sacrococcygeal teratoma.

    PubMed

    Zaccara, Antonio; Iacobelli, Barbara D; Adorisio, Ottavio; Petrarca, Maurizio; Di Rosa, Giuseppe; Pierro, Marcello M; Bagolan, Pietro

    2004-06-01

    Long-term follow-up of sacrococcygeal teratoma (SCT) is well established; however, little is known about the effects of extensive surgery in the pelvic and perineal region, which involves disruption of muscles providing maximal support in normal walking. Thirteen patients operated on at birth for SCT with extensive muscle dissection underwent gait studies with a Vicon 3-D motion analysis system with 6 cameras. Results were compared with 15 age-matched controls. Statistical analysis was performed with Mann-Whitney test; correlations were sought with Spearman's correlation coefficient. All subjects were independent ambulators, and no statistically significant differences were seen in walking velocity and stride length. However, in all patients, toe-off occurred earlier (at 58% +/- 1.82% of stride length) than controls (at 65.5% +/- 0.52%; P <.05). On kinetics, all patients exhibited, on both limbs, a significant reduction of hip extensory moment (-0.11 +/- 0.11 left; -0.16 +/- 0.15 right v 1.19 +/- 0.08 Newtonmeter/kg; P <.05) and of ankle dorsi/plantar moment (-0.07 +/- 0.09 right; -0.08 +/- 0.16 v -0.15 +/- 0.05 Nm/kg, p < 0.05). Knee power was also significantly reduced (0.44 +/- 0.55 right, 0.63 +/- 0.45 left v 0.04 +/- 0.05 W/kg), whereas ankle power was increased (3 +/- 1.5 right; 2.8 +/- 0.9 left v 1.97 +/- 0.2 W/kg; P <.05). No statistically significant correlation was found between tumor size and either muscle power generation or flexory/extensory moments. Patients operated on for SCT exhibit nearly normal gait patterns. However, this normal pattern is accompanied by abnormal kinetics of some ambulatory muscles, and the extent of these abnormalities appears to be independent of tumor size. A careful follow-up is warranted to verify if such modifications are stable or progress over the years, thereby impairing ambulatory potential or leading to early arthrosis.

  18. Electricity production from municipal solid waste using microbial fuel cells.

    PubMed

    Chiu, H Y; Pai, T Y; Liu, M H; Chang, C A; Lo, F C; Chang, T C; Lo, H M; Chiang, C F; Chao, K P; Lo, W Y; Lo, S W; Chu, Y L

    2016-07-01

    The organic content of municipal solid waste has long been an attractive source of renewable energy, mainly as a solid fuel in waste-to-energy plants. This study focuses on the potential to use microbial fuel cells to convert municipal solid waste organics into energy using various operational conditions. The results showed that two-chamber microbial fuel cells with carbon felt and carbon felt allocation had a higher maximal power density (20.12 and 30.47 mW m(-2) for 1.5 and 4 L, respectively) than those of other electrode plate allocations. Most two-chamber microbial fuel cells (1.5 and 4 L) had a higher maximal power density than single-chamber ones with corresponding electrode plate allocations. Municipal solid waste with alkali hydrolysis pre-treatment and K3Fe(CN)6 as an electron acceptor improved the maximal power density to 1817.88 mW m(-2) (~0.49% coulomb efficiency, from 0.05-0.49%). The maximal power density from experiments using individual 1.5 and 4 L two-chamber microbial fuel cells, and serial and parallel connections of 1.5 and 4 L two-chamber microbial fuel cells, was found to be in the order of individual 4 L (30.47 mW m(-2)) > serial connection of 1.5 and 4 L (27.75) > individual 1.5 L (20.12) > parallel connection of 1.5 and 4 L (17.04) two-chamber microbial fuel cells . The power density using municipal solid waste microbial fuel cells was compared with information in the literature and discussed. © The Author(s) 2016.

  19. The effects of load on system and lower-body joint kinetics during jump squats.

    PubMed

    Moir, Gavin L; Gollie, Jared M; Davis, Shala E; Guers, John J; Witmer, Chad A

    2012-11-01

    To investigate the effects of different loads on system and lower-body kinetics during jump squats, 12 resistance-trained men performed jumps under different loading conditions: 0%, 12%, 27%, 42%, 56%, 71%, and 85% of 1-repetition maximum (1-RM). System power output was calculated as the product of the vertical component of the ground reaction force and the vertical velocity of the bar during its ascent. Joint power output was calculated during bar ascent for the hip, knee, and ankle joints, and was also summed across the joints. System power output and joint power at knee and ankle joints were maximized at 0% 1-RM (p < 0.001) and followed the linear trends (p < 0.001) caused by power output decreasing as the load increased. Power output at the hip was maximized at 42% 1-RM (p = 0.016) and followed a quadratic trend (p = 0.030). Summed joint power could be predicted from system power (p < 0.05), while system power could predict power at the knee and ankle joints under some of the loading conditions. Power at the hip could not be predicted from system power. System power during loaded jumps reflects the power at the knee and ankle, while power at the hip does not correspond to system power.

  20. Leg Strength or Velocity of Movement Which Is More Influential on the Balance of Mobility Limited Elders?

    PubMed Central

    Mayson, Douglas J.; Kiely, Dan K.; LaRose, Sharon I.; Bean, Jonathan F.

    2009-01-01

    Objective To determine which component of leg power (maximal limb strength or limb velocity) is more influential on balance performance in mobility limited elders. Design In this cross-sectional analysis we evaluated 138 community-dwelling older adults with mobility limitation. Balance was measured using the Unipedal Stance Test, the Berg Balance Test (BERG), the Dynamic Gait Index, and the performance-oriented mobility assessment. We measured one repetition maximum strength and power at 40% one repetition maximum strength, from which velocity was calculated. The associations between maximal estimated leg strength and velocity with balance performance were examined using separate multivariate logistic regression models. Results Strength was found to be associated [odds ratio of 1.06 (95% confidence interval, 1.01–1.11)] with performance on the Unipedal Stance Test, whereas velocity showed no statistically significant association. In contrast, velocity was consistently associated with performance on all composite measures of balance [BERG 14.23 (1.84–109.72), performance-oriented mobility assessment 33.92 (3.69–312.03), and Dynamic Gait Index 35.80 (4.77–268.71))]. Strength was only associated with the BERG 1.08 (1.01–1.14). Conclusions Higher leg press velocity is associated with better performance on the BERG, performance-oriented mobility assessment, and Dynamic Gait Index, whereas greater leg strength is associated with better performance on the Unipedal Stance Test and the BERG. These findings are likely related to the intrinsic qualities of each test and emphasize the relevance of limb velocity. PMID:19033758

  1. Uplink Array Calibration via Far-Field Power Maximization

    NASA Technical Reports Server (NTRS)

    Vilnrotter, V.; Mukai, R.; Lee, D.

    2006-01-01

    Uplink antenna arrays have the potential to greatly increase the Deep Space Network s high-data-rate uplink capabilities as well as useful range, and to provide additional uplink signal power during critical spacecraft emergencies. While techniques for calibrating an array of receive antennas have been addressed previously, proven concepts for uplink array calibration have yet to be demonstrated. This article describes a method of utilizing the Moon as a natural far-field reflector for calibrating a phased array of uplink antennas. Using this calibration technique, the radio frequency carriers transmitted by each antenna of the array are optimally phased to ensure that the uplink power received by the spacecraft is maximized.

  2. Maximizing power output from continuous-wave single-frequency fiber amplifiers.

    PubMed

    Ward, Benjamin G

    2015-02-15

    This Letter reports on a method of maximizing the power output from highly saturated cladding-pumped continuous-wave single-frequency fiber amplifiers simultaneously, taking into account the stimulated Brillouin scattering and transverse modal instability thresholds. This results in a design figure of merit depending on the fundamental mode overlap with the doping profile, the peak Brillouin gain coefficient, and the peak mode coupling gain coefficient. This figure of merit is then numerically analyzed for three candidate fiber designs including standard, segmented acoustically tailored, and micro-segmented acoustically tailored photonic-crystal fibers. It is found that each of the latter two fibers should enable a 50% higher output power than standard photonic crystal fiber.

  3. Sunspot activity and influenza pandemics: a statistical assessment of the purported association.

    PubMed

    Towers, S

    2017-10-01

    Since 1978, a series of papers in the literature have claimed to find a significant association between sunspot activity and the timing of influenza pandemics. This paper examines these analyses, and attempts to recreate the three most recent statistical analyses by Ertel (1994), Tapping et al. (2001), and Yeung (2006), which all have purported to find a significant relationship between sunspot numbers and pandemic influenza. As will be discussed, each analysis had errors in the data. In addition, in each analysis arbitrary selections or assumptions were also made, and the authors did not assess the robustness of their analyses to changes in those arbitrary assumptions. Varying the arbitrary assumptions to other, equally valid, assumptions negates the claims of significance. Indeed, an arbitrary selection made in one of the analyses appears to have resulted in almost maximal apparent significance; changing it only slightly yields a null result. This analysis applies statistically rigorous methodology to examine the purported sunspot/pandemic link, using more statistically powerful un-binned analysis methods, rather than relying on arbitrarily binned data. The analyses are repeated using both the Wolf and Group sunspot numbers. In all cases, no statistically significant evidence of any association was found. However, while the focus in this particular analysis was on the purported relationship of influenza pandemics to sunspot activity, the faults found in the past analyses are common pitfalls; inattention to analysis reproducibility and robustness assessment are common problems in the sciences, that are unfortunately not noted often enough in review.

  4. Changes in power and force generation during coupled eccentric-concentric versus concentric muscle contraction with training and aging.

    PubMed

    Caserotti, Paolo; Aagaard, Per; Puggaard, Lis

    2008-05-01

    Age-related decline in maximal concentric muscle power is associated with frailty and functional impairments in the elderly. Compared to concentric contraction, mechanical muscle output is generally enhanced when muscles are rapidly pre-stretched (eccentric contraction), albeit less pronounced with increasing age. Exercise has been recommended to prevent loss of muscle power and function and recent guidelines indicate training program for increasing muscle power highly relevant for elderly subjects. This study examined the differences in muscle power, force and movement pattern during concentric-alone and coupled eccentric-concentric contraction and selected functional motor performances before and after 36-week multicomponent training including aerobic, strength, balance, flexibility and coordination components in elderly males. Vertical force, excursion, velocity, power and acceleration of the body center of mass were measured in two standardised vertical jumps (squatting jump, SQJ; countermovement jump, CMJ). Pre-stretch enhancement during CMJ did not improve performance [i.e., no enhanced maximal muscle power (Ppeak) and jump height (JH)] compared to concentric-alone muscle contraction (SQJ). Nevertheless, pre-stretch enhancement occurred as for similar SQJ and CMJ maximal performance, elderly people employed lower mechanical work, higher mean muscle power (Pmean), shorter concentric phase duration and shorter body center of mass displacement during CMJ. Post training, CMJ Ppeak, Pmean and JH increased in training group (P<0.05) while Ppeak and JH decreased in control group during the CMJ and SQJ (P<0.05). In conclusion, long-term training counteracted the age-related decline in muscle power and functional performance observed in the control subjects, while substantial gains in muscular performance were observed in the trained elderly.

  5. Power transformation for enhancing responsiveness of quality of life questionnaire.

    PubMed

    Zhou, YanYan Ange

    2015-01-01

    We investigate the effect of power transformation of raw scores on the responsiveness of quality of life survey. The procedure maximizes the paired t-test value on the power transformed data to obtain an optimal power range. The parallel between the Box-Cox transformation is also investigated for the quality of life data.

  6. Comparison of cosmology and seabed acoustics measurements using statistical inference from maximum entropy

    NASA Astrophysics Data System (ADS)

    Knobles, David; Stotts, Steven; Sagers, Jason

    2012-03-01

    Why can one obtain from similar measurements a greater amount of information about cosmological parameters than seabed parameters in ocean waveguides? The cosmological measurements are in the form of a power spectrum constructed from spatial correlations of temperature fluctuations within the microwave background radiation. The seabed acoustic measurements are in the form of spatial correlations along the length of a spatial aperture. This study explores the above question from the perspective of posterior probability distributions obtained from maximizing a relative entropy functional. An answer is in part that the seabed in shallow ocean environments generally has large temporal and spatial inhomogeneities, whereas the early universe was a nearly homogeneous cosmological soup with small but important fluctuations. Acoustic propagation models used in shallow water acoustics generally do not capture spatial and temporal variability sufficiently well, which leads to model error dominating the statistical inference problem. This is not the case in cosmology. Further, the physics of the acoustic modes in cosmology is that of a standing wave with simple initial conditions, whereas for underwater acoustics it is a traveling wave in a strongly inhomogeneous bounded medium.

  7. Spectrum and power allocation in cognitive multi-beam satellite communications with flexible satellite payloads

    NASA Astrophysics Data System (ADS)

    Liu, Zhihui; Wang, Haitao; Dong, Tao; Yin, Jie; Zhang, Tingting; Guo, Hui; Li, Dequan

    2018-02-01

    In this paper, the cognitive multi-beam satellite system, i.e., two satellite networks coexist through underlay spectrum sharing, is studied, and the power and spectrum allocation method is employed for interference control and throughput maximization. Specifically, the multi-beam satellite with flexible payload reuses the authorized spectrum of the primary satellite, adjusting its transmission band as well as power for each beam to limit its interference on the primary satellite below the prescribed threshold and maximize its own achievable rate. This power and spectrum allocation problem is formulated as a mixed nonconvex programming. For effective solving, we first introduce the concept of signal to leakage plus noise ratio (SLNR) to decouple multiple transmit power variables in the both objective and constraint, and then propose a heuristic algorithm to assign spectrum sub-bands. After that, a stepwise plus slice-wise algorithm is proposed to implement the discrete power allocation. Finally, simulation results show that adopting cognitive technology can improve spectrum efficiency of the satellite communication.

  8. Strength testing and training of rowers: a review.

    PubMed

    Lawton, Trent W; Cronin, John B; McGuigan, Michael R

    2011-05-01

    In the quest to maximize average propulsive stroke impulses over 2000-m racing, testing and training of various strength parameters have been incorporated into the physical conditioning plans of rowers. Thus, the purpose of this review was 2-fold: to identify strength tests that were reliable and valid correlates (predictors) of rowing performance; and, to establish the benefits gained when strength training was integrated into the physical preparation plans of rowers. The reliability of maximal strength and power tests involving leg extension (e.g. leg pressing) and arm pulling (e.g. prone bench pull) was high (intra-class correlations 0.82-0.99), revealing that elite rowers were significantly stronger than their less competitive peers. The greater strength of elite rowers was in part attributed to the correlation between strength and greater lean body mass (r = 0.57-0.63). Dynamic lower body strength tests that determined the maximal external load for a one-repetition maximum (1RM) leg press (kg), isokinetic leg extension peak force (N) or leg press peak power (W) proved to be moderately to strongly associated with 2000-m ergometer times (r = -0.54 to -0.68; p < 0.05). Repetition tests that assess muscular or strength endurance by quantifying the number of repetitions accrued at a fixed percentage of the strength maximum (e.g. 50-70% 1RM leg press) or set absolute load (e.g. 40 kg prone bench pulls) were less reliable and more time consuming when compared with briefer maximal strength tests. Only leg press repetition tests were correlated with 2000-m ergometer times (e.g. r = -0.67; p < 0.05). However, these tests differentiate training experience and muscle morphology, in that those individuals with greater training experience and/or proportions of slow twitch fibres performed more repetitions. Muscle balance ratios derived from strength data (e.g. hamstring-quadriceps ratio <45% or knee extensor-elbow flexor ratio around 4.2 ± 0.22 to 1) appeared useful in the pathological assessment of low back pain or rib injury history associated with rowing. While strength partially explained variances in 2000-m ergometer performance, concurrent endurance training may be counterproductive to strength development over the shorter term (i.e. <12 weeks). Therefore, prioritization of strength training within the sequence of training units should be considered, particularly over the non-competition phase (e.g. 2-6 sets × 4-12 repetitions, three sessions a week). Maximal strength was sustained when infrequent (e.g. one or two sessions a week) but intense (e.g. 73-79% of maximum) strength training units were scheduled; however, it was unclear whether training adaptations should emphasize maximal strength, endurance or power in order to enhance performance during the competition phase. Additionally, specific on-water strength training practices such as towing ropes had not been reported. Further research should examine the on-water benefits associated with various strength training protocols, in the context of the training phase, weight division, experience and level of rower, if limitations to the reliability and precision of performance data (e.g. 2000-m time or rank) can be controlled. In conclusion, while positive ergometer time-trial benefits of clinical and practical significance were reported with strength training, a lack of statistical significance was noted, primarily due to an absence of quality long-term controlled experimental research designs.

  9. Power-up: A Reanalysis of 'Power Failure' in Neuroscience Using Mixture Modeling

    PubMed Central

    Wood, John

    2017-01-01

    Recently, evidence for endemically low statistical power has cast neuroscience findings into doubt. If low statistical power plagues neuroscience, then this reduces confidence in the reported effects. However, if statistical power is not uniformly low, then such blanket mistrust might not be warranted. Here, we provide a different perspective on this issue, analyzing data from an influential study reporting a median power of 21% across 49 meta-analyses (Button et al., 2013). We demonstrate, using Gaussian mixture modeling, that the sample of 730 studies included in that analysis comprises several subcomponents so the use of a single summary statistic is insufficient to characterize the nature of the distribution. We find that statistical power is extremely low for studies included in meta-analyses that reported a null result and that it varies substantially across subfields of neuroscience, with particularly low power in candidate gene association studies. Therefore, whereas power in neuroscience remains a critical issue, the notion that studies are systematically underpowered is not the full story: low power is far from a universal problem. SIGNIFICANCE STATEMENT Recently, researchers across the biomedical and psychological sciences have become concerned with the reliability of results. One marker for reliability is statistical power: the probability of finding a statistically significant result given that the effect exists. Previous evidence suggests that statistical power is low across the field of neuroscience. Our results present a more comprehensive picture of statistical power in neuroscience: on average, studies are indeed underpowered—some very seriously so—but many studies show acceptable or even exemplary statistical power. We show that this heterogeneity in statistical power is common across most subfields in neuroscience. This new, more nuanced picture of statistical power in neuroscience could affect not only scientific understanding, but potentially policy and funding decisions for neuroscience research. PMID:28706080

  10. Magnetic resonance spectra and statistical geometry

    USDA-ARS?s Scientific Manuscript database

    Methods of statistical geometry are introduced which allow one to estimate, on the basis of computable criteria, the conditions under which maximally informative data may be collected. We note the important role of constraints that introduce curvature into parameter space and discuss the appropriate...

  11. Expectation maximization for hard X-ray count modulation profiles

    NASA Astrophysics Data System (ADS)

    Benvenuto, F.; Schwartz, R.; Piana, M.; Massone, A. M.

    2013-07-01

    Context. This paper is concerned with the image reconstruction problem when the measured data are solar hard X-ray modulation profiles obtained from the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) instrument. Aims: Our goal is to demonstrate that a statistical iterative method classically applied to the image deconvolution problem is very effective when utilized to analyze count modulation profiles in solar hard X-ray imaging based on rotating modulation collimators. Methods: The algorithm described in this paper solves the maximum likelihood problem iteratively and encodes a positivity constraint into the iterative optimization scheme. The result is therefore a classical expectation maximization method this time applied not to an image deconvolution problem but to image reconstruction from count modulation profiles. The technical reason that makes our implementation particularly effective in this application is the use of a very reliable stopping rule which is able to regularize the solution providing, at the same time, a very satisfactory Cash-statistic (C-statistic). Results: The method is applied to both reproduce synthetic flaring configurations and reconstruct images from experimental data corresponding to three real events. In this second case, the performance of expectation maximization, when compared to Pixon image reconstruction, shows a comparable accuracy and a notably reduced computational burden; when compared to CLEAN, shows a better fidelity with respect to the measurements with a comparable computational effectiveness. Conclusions: If optimally stopped, expectation maximization represents a very reliable method for image reconstruction in the RHESSI context when count modulation profiles are used as input data.

  12. Statistical iterative reconstruction for streak artefact reduction when using multidetector CT to image the dento-alveolar structures.

    PubMed

    Dong, J; Hayakawa, Y; Kober, C

    2014-01-01

    When metallic prosthetic appliances and dental fillings exist in the oral cavity, the appearance of metal-induced streak artefacts is not avoidable in CT images. The aim of this study was to develop a method for artefact reduction using the statistical reconstruction on multidetector row CT images. Adjacent CT images often depict similar anatomical structures. Therefore, reconstructed images with weak artefacts were attempted using projection data of an artefact-free image in a neighbouring thin slice. Images with moderate and strong artefacts were continuously processed in sequence by successive iterative restoration where the projection data was generated from the adjacent reconstructed slice. First, the basic maximum likelihood-expectation maximization algorithm was applied. Next, the ordered subset-expectation maximization algorithm was examined. Alternatively, a small region of interest setting was designated. Finally, the general purpose graphic processing unit machine was applied in both situations. The algorithms reduced the metal-induced streak artefacts on multidetector row CT images when the sequential processing method was applied. The ordered subset-expectation maximization and small region of interest reduced the processing duration without apparent detriments. A general-purpose graphic processing unit realized the high performance. A statistical reconstruction method was applied for the streak artefact reduction. The alternative algorithms applied were effective. Both software and hardware tools, such as ordered subset-expectation maximization, small region of interest and general-purpose graphic processing unit achieved fast artefact correction.

  13. High power broadband all fiber super-fluorescent source with linear polarization and near diffraction-limited beam quality.

    PubMed

    Ma, Pengfei; Huang, Long; Wang, Xiaolin; Zhou, Pu; Liu, Zejin

    2016-01-25

    In this manuscript, a high power broadband superfluorescent source (SFS) with linear polarization and near-diffraction-limited beam quality is achieved based on an ytterbium-doped (Yb-doped), all fiberized and polarization-maintained master oscillator power amplifier (MOPA) configuration. The MOPA structure generates a linearly polarized output power of 1427 W with a slope efficiency of 80% and a full width at half maximum (FWHM) of 11 nm, which is power scaled by an order of magnitude compared with the previously reported SFSs with linear polarization. In the experiment, both the polarization extinction ratio (PER) and beam quality (M(2) factor) are degraded little during the power scaling process. At maximal output power, the PER and M(2) factor are measured to be 19.1dB and 1.14, respectively. The root-mean-square (RMS) and peak-vale (PV) values of the power fluctuation at maximal output power are just 0.48% and within 3%, respectively. Further power scaling of the whole system is limited by the available pump sources. To the best of our knowledge, this is the first demonstration of kilowatt level broadband SFS with linear polarization and near-diffraction-limited beam quality.

  14. A phenomenological model of muscle fatigue and the power-endurance relationship.

    PubMed

    James, A; Green, S

    2012-11-01

    The relationship between power output and the time that it can be sustained during exercise (i.e., endurance) at high intensities is curvilinear. Although fatigue is implicit in this relationship, there is little evidence pertaining to it. To address this, we developed a phenomenological model that predicts the temporal response of muscle power during submaximal and maximal exercise and which was based on the type, contractile properties (e.g., fatiguability), and recruitment of motor units (MUs) during exercise. The model was first used to predict power outputs during all-out exercise when fatigue is clearly manifest and for several distributions of MU type. The model was then used to predict times that different submaximal power outputs could be sustained for several MU distributions, from which several power-endurance curves were obtained. The model was simultaneously fitted to two sets of human data pertaining to all-out exercise (power-time profile) and submaximal exercise (power-endurance relationship), yielding a high goodness of fit (R(2) = 0.96-0.97). This suggested that this simple model provides an accurate description of human power output during submaximal and maximal exercise and that fatigue-related processes inherent in it account for the curvilinearity of the power-endurance relationship.

  15. Budget Allocation in a Competitive Communication Spectrum Economy

    NASA Astrophysics Data System (ADS)

    Lin, Ming-Hua; Tsai, Jung-Fa; Ye, Yinyu

    2009-12-01

    This study discusses how to adjust "monetary budget" to meet each user's physical power demand, or balance all individual utilities in a competitive "spectrum market" of a communication system. In the market, multiple users share a common frequency or tone band and each of them uses the budget to purchase its own transmit power spectra (taking others as given) in maximizing its Shannon utility or pay-off function that includes the effect of interferences. A market equilibrium is a budget allocation, price spectrum, and tone power distribution that independently and simultaneously maximizes each user's utility. The equilibrium conditions of the market are formulated and analyzed, and the existence of an equilibrium is proved. Computational results and comparisons between the competitive equilibrium and Nash equilibrium solutions are also presented, which show that the competitive market equilibrium solution often provides more efficient power distribution.

  16. Strength and power predictors of sports speed.

    PubMed

    Cronin, John B; Hansen, Keir T

    2005-05-01

    For many sporting activities, initial speed rather than maximal speed would be considered of greater importance to successful performance. The purpose of this study was to identify the relationship between strength and power and measures of first-step quickness (5-m time), acceleration (10-m time), and maximal speed (30-m time). The maximal strength (3 repetition maximum [3RM]), power (30-kg jump squat, countermovement, and drop jumps), isokinetic strength measures (hamstring and quadriceps peak torques and ratios at 60 degrees .s(-1) and 300 degrees .s(-1)) and 5-m, 10-m, and 30-m sprint times of 26 part-time and full-time professional rugby league players (age 23.2 +/- 3.3 years) were measured. To examine the importance of the strength and power measures on sprint performance, a correlational approach and a comparison between means of the fastest and slowest players was used. The correlations between the 3RM, drop jump, isokinetic strength measures, and the 3 measures of sport speed were nonsignificant. Correlations between the jump squat (height and relative power output) and countermovement jump height and the 3 speed measures were significant (r = -0.43 to -0.66, p < 0.05). The squat and countermovement jump heights as well as squat jump relative power output were the only variables found to be significantly greater in the fast players. It was suggested that improving the power to weight ratio as well as plyometric training involving countermovement and loaded jump-squat training may be more effective for enhancing sport speed in elite players.

  17. Predicting punching acceleration from selected strength and power variables in elite karate athletes: a multiple regression analysis.

    PubMed

    Loturco, Irineu; Artioli, Guilherme Giannini; Kobal, Ronaldo; Gil, Saulo; Franchini, Emerson

    2014-07-01

    This study investigated the relationship between punching acceleration and selected strength and power variables in 19 professional karate athletes from the Brazilian National Team (9 men and 10 women; age, 23 ± 3 years; height, 1.71 ± 0.09 m; and body mass [BM], 67.34 ± 13.44 kg). Punching acceleration was assessed under 4 different conditions in a randomized order: (a) fixed distance aiming to attain maximum speed (FS), (b) fixed distance aiming to attain maximum impact (FI), (c) self-selected distance aiming to attain maximum speed, and (d) self-selected distance aiming to attain maximum impact. The selected strength and power variables were as follows: maximal dynamic strength in bench press and squat-machine, squat and countermovement jump height, mean propulsive power in bench throw and jump squat, and mean propulsive velocity in jump squat with 40% of BM. Upper- and lower-body power and maximal dynamic strength variables were positively correlated to punch acceleration in all conditions. Multiple regression analysis also revealed predictive variables: relative mean propulsive power in squat jump (W·kg-1), and maximal dynamic strength 1 repetition maximum in both bench press and squat-machine exercises. An impact-oriented instruction and a self-selected distance to start the movement seem to be crucial to reach the highest acceleration during punching execution. This investigation, while demonstrating strong correlations between punching acceleration and strength-power variables, also provides important information for coaches, especially for designing better training strategies to improve punching speed.

  18. The effect of active recovery on power performance during the bench press exercise.

    PubMed

    Lopes, Felipe A S; Panissa, Valéria L G; Julio, Ursula F; Menegon, Elton M; Franchini, Emerson

    2014-03-27

    The objective of this study was to verify the effect of active and passive recovery on blood lactate concentration and power performance. Twelve male subjects were submitted to a maximal strength test in the the bench press, a maximal aerobic test in the bench step, and to four sets of bench press exercise performed as fast and as long as possible, using 80% of maximal strength when active or passive recovery was performed. The maximum number of repetitions, mean and peak power in eccentric and concentric phases were computed and blood lactate concentration was measured. Comparisons for the variables were made using a two-way variance analysis (recovery type and set numer) with repeated measures in the second factor. When significant differences were detected (p < 0.05), a Tukey post-hoc test was used. There was a main effect of set number on maximum number of repetitions (p < 0.05) (1 > 2, 3, and 4; 2 > 3 and 4; 3 > 4). Mean and peak power in both eccentric and concentric phases also differed across sets (1 > 2, 3, and 4; 2 > 4). There was also a main effect for the recovery type, with lower values (p < 0.05) observed for the active recovery compared to the passive one. It can be concluded that active recovery resulted in lower lactate concentration, but did not improve power performance in the bench press exercise.

  19. Biofuel cells based on direct enzyme-electrode contacts using PQQ-dependent glucose dehydrogenase/bilirubin oxidase and modified carbon nanotube materials.

    PubMed

    Scherbahn, V; Putze, M T; Dietzel, B; Heinlein, T; Schneider, J J; Lisdat, F

    2014-11-15

    Two types of carbon nanotube electrodes (1) buckypaper (BP) and (2) vertically aligned carbon nanotubes (vaCNT) have been used for elaboration of glucose/O2 enzymatic fuel cells exploiting direct electron transfer. For the anode pyrroloquinoline quinone dependent glucose dehydrogenase ((PQQ)GDH) has been immobilized on [poly(3-aminobenzoic acid-co-2-methoxyaniline-5-sulfonic acid), PABMSA]-modified electrodes. For the cathode bilirubin oxidase (BOD) has been immobilized on PQQ-modified electrodes. PABMSA and PQQ act as promoter for enzyme bioelectrocatalysis. The voltammetric characterization of each electrode shows current densities in the range of 0.7-1.3 mA/cm(2). The BP-based fuel cell exhibits maximal power density of about 107 µW/cm(2) (at 490 mV). The vaCNT-based fuel cell achieves a maximal power density of 122 µW/cm(2) (at 540 mV). Even after three days and several runs of load a power density over 110 µW/cm(2) is retained with the second system (10mM glucose). Due to a better power exhibition and an enhanced stability of the vaCNT-based fuel cells they have been studied in human serum samples and a maximal power density of 41 µW/cm(2) (390 mV) can be achieved. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Influence of crank length and crank width on maximal hand cycling power and cadence.

    PubMed

    Krämer, Christian; Hilker, Lutz; Böhm, Harald

    2009-07-01

    The effect of different crank lengths and crank widths on maximal hand cycling power, cadence and handle speed were determined. Crank lengths and crank widths were adapted to anthropometric data of the participants as the ratio to forward reach (FR) and shoulder breadth (SB), respectively. 25 able-bodied subjects performed maximal inertial load hand cycle ergometry using crank lengths of 19, 22.5 and 26% of FR and 72, 85 and 98% of SB. Maximum power ranged from 754 (246) W for the crank geometry short wide (crank length x crank width) to 873 (293) W for the combination long middle. Every crank length differed significantly (P < 0.05) from each other, whereas no significant effect of crank width to maximum power output was revealed. Optimal cadence decreased significantly (P < 0.001) with increasing crank length from 124.8 (0.9) rpm for the short to 107.5 (1.6) rpm for the long cranks, whereas optimal handle speed increased significantly (P < 0.001) with increasing crank length from 1.81 (0.01) m/s for the short to 2.13 (0.03) m/s for the long cranks. Crank width did neither influence optimal cadence nor optimal handle speed significantly. From the results of this study, for maximum hand cycling power, a crank length to FR ratio of 26% for a crank width to SB ratio of 85% is recommended.

  1. The Effect of Active Recovery on Power Performance During the Bench Press Exercise

    PubMed Central

    Lopes, Felipe A. S.; Panissa, Valéria L. G.; Julio, Ursula F.; Menegon, Elton M.; Franchini, Emerson

    2014-01-01

    The objective of this study was to verify the effect of active and passive recovery on blood lactate concentration and power performance. Twelve male subjects were submitted to a maximal strength test in the the bench press, a maximal aerobic test in the bench step, and to four sets of bench press exercise performed as fast and as long as possible, using 80% of maximal strength when active or passive recovery was performed. The maximum number of repetitions, mean and peak power in eccentric and concentric phases were computed and blood lactate concentration was measured. Comparisons for the variables were made using a two-way variance analysis (recovery type and set numer) with repeated measures in the second factor. When significant differences were detected (p < 0.05), a Tukey post-hoc test was used. There was a main effect of set number on maximum number of repetitions (p < 0.05) (1 > 2, 3, and 4; 2 > 3 and 4; 3 > 4). Mean and peak power in both eccentric and concentric phases also differed across sets (1 > 2, 3, and 4; 2 > 4). There was also a main effect for the recovery type, with lower values (p < 0.05) observed for the active recovery compared to the passive one. It can be concluded that active recovery resulted in lower lactate concentration, but did not improve power performance in the bench press exercise. PMID:25031684

  2. Evidence for Endothermy in Pterosaurs Based on Flight Capability Analyses

    NASA Astrophysics Data System (ADS)

    Jenkins, H. S.; Pratson, L. F.

    2005-12-01

    Previous attempts to constrain flight capability in pterosaurs have relied heavily on the fossil record, using bone articulation and apparent muscle allocation to evaluate flight potential (Frey et al., 1997; Padian, 1983; Bramwell, 1974). However, broad definitions of the physical parameters necessary for flight in pterosaurs remain loosely defined and few systematic approaches to constraining flight capability have been synthesized (Templin, 2000; Padian, 1983). Here we present a new method to assess flight capability in pterosaurs as a function of humerus length and flight velocity. By creating an energy-balance model to evaluate the power required for flight against the power available to the animal, we derive a `U'-shaped power curve and infer optimal flight speeds and maximal wingspan lengths for pterosaurs Quetzalcoatlus northropi and Pteranodon ingens. Our model corroborates empirically derived power curves for the modern black-billed magpie ( Pica Pica) and accurately reproduces the mechanical power curve for modern cockatiels ( Nymphicus hollandicus) (Tobalske et al., 2003). When we adjust our model to include an endothermic metabolic rate for pterosaurs, we find a maximal wingspan length of 18 meters for Q. northropi. Model runs using an exothermic metabolism derive maximal wingspans of 6-8 meters. As estimates based on fossil evidence show total wingspan lengths reaching up to 15 meters for Q. northropi, we conclude that large pterosaurs may have been endothermic and therefore more metabolically similar to birds than to reptiles.

  3. Maximal Power of the Lower Limbs of Youth Gymnasts and Biomechanical Indicators of the Forward Handspring Vault Versus the Sports Result

    PubMed Central

    Kochanowicz, Andrzej; Kochanowicz, Kazimierz; Mieszkowski, Jan; Aschenbrenner, Piotr; Bielec, Grzegorz; Szark-Eckardt, Mirosława

    2016-01-01

    Abstract The aim of the study was to define the relationship between maximal power of lower limbs, the biomechanics of the forward handspring vault and the score received during a gymnastics competition. The research involved 42 gymnasts aged 9-11 years competing in the Poland’s Junior Championships. The study consisted of three stages: first -estimating the level of indicators of maximal power of lower limbs tested on a force plate during the countermovement jump; second - estimating the level of biomechanical indicators of the front handspring vault. For both mentioned groups of indicators and the score received by gymnasts during the vault, linear correlation analyses were made. The last stage consisted of conducting multiple regression analysis in order to predict the performance level of the front handspring vault. Results showed a positive correlation (0.401, p < 0.05) of lower limbs’ maximal power (1400 ± 502 W) with the judges’ score for the front handstand vault (13.38 ± 1.02 points). However, the highest significant (p < 0.001) correlation with the judges’ score was revealed in the angle of the hip joint in the second phase of the flight (196.00 ± 16.64°) and the contact time of hands with the vault surface (0.264 ± 0.118 s), where correlation coefficients were: -0.671 and -0.634, respectively. In conclusion, the angles of the hip joint in the second phase of the flight and when the hands touched the vault surface proved to be the most important indicators for the received score. PMID:28149408

  4. OASIS 2: online application for survival analysis 2 with features for the analysis of maximal lifespan and healthspan in aging research.

    PubMed

    Han, Seong Kyu; Lee, Dongyeop; Lee, Heetak; Kim, Donghyo; Son, Heehwa G; Yang, Jae-Seong; Lee, Seung-Jae V; Kim, Sanguk

    2016-08-30

    Online application for survival analysis (OASIS) has served as a popular and convenient platform for the statistical analysis of various survival data, particularly in the field of aging research. With the recent advances in the fields of aging research that deal with complex survival data, we noticed a need for updates to the current version of OASIS. Here, we report OASIS 2 (http://sbi.postech.ac.kr/oasis2), which provides extended statistical tools for survival data and an enhanced user interface. In particular, OASIS 2 enables the statistical comparison of maximal lifespans, which is potentially useful for determining key factors that limit the lifespan of a population. Furthermore, OASIS 2 provides statistical and graphical tools that compare values in different conditions and times. That feature is useful for comparing age-associated changes in physiological activities, which can be used as indicators of "healthspan." We believe that OASIS 2 will serve as a standard platform for survival analysis with advanced and user-friendly statistical tools for experimental biologists in the field of aging research.

  5. Experimental design approach to the process parameter optimization for laser welding of martensitic stainless steels in a constrained overlap configuration

    NASA Astrophysics Data System (ADS)

    Khan, M. M. A.; Romoli, L.; Fiaschi, M.; Dini, G.; Sarri, F.

    2011-02-01

    This paper presents an experimental design approach to process parameter optimization for the laser welding of martensitic AISI 416 and AISI 440FSe stainless steels in a constrained overlap configuration in which outer shell was 0.55 mm thick. To determine the optimal laser-welding parameters, a set of mathematical models were developed relating welding parameters to each of the weld characteristics. These were validated both statistically and experimentally. The quality criteria set for the weld to determine optimal parameters were the minimization of weld width and the maximization of weld penetration depth, resistance length and shearing force. Laser power and welding speed in the range 855-930 W and 4.50-4.65 m/min, respectively, with a fiber diameter of 300 μm were identified as the optimal set of process parameters. However, the laser power and welding speed can be reduced to 800-840 W and increased to 4.75-5.37 m/min, respectively, to obtain stronger and better welds.

  6. Sex differences in neuromuscular function after repeated eccentric contractions of the knee extensor muscles.

    PubMed

    Lee, Andrea; Baxter, Jake; Eischer, Claire; Gage, Matt; Hunter, Sandra; Yoon, Tejin

    2017-06-01

    This study examined the mechanisms for force and power reduction during and up to 48 h after maximal eccentric contractions of the knee extensor muscles in young men and women. 13 men (22.8 ± 2.6 years) and 13 women (21.6 ± 2.2 years) performed 150 maximal effort eccentric contractions (5 sets of 30) with the knee extensor muscles at 60° s -1 . Maximal voluntary isometric contractions (MVIC) and maximal voluntary concentric contractions (MVCC) were performed before and after the 150 eccentric contractions. The MVCCs involved a set of two isokinetic contractions at 60° s -1 and sets of isotonic contractions performed at seven different resistance loads (1 N m, 10, 20, 30, 40, 50, and 60% MVIC). Electrical stimulation was used during the MVICs and at rest to determine changes in voluntary activation and contractile properties. At baseline, men were stronger than women (MVIC: 276 ± 48 vs. 133 ± 37 N m) and more powerful (MVCC: 649 ± 77 vs. 346 ± 78 W). At termination of the eccentric contractions, voluntary activation, resting twitch amplitude, and peak power during concentric contractions at the seven loads and at 60° s -1 decreased (P < 0.05) similarly in the men and women. At 48 h post-exercise, the MVIC torque, power (for loads ≥20-60% MVIC), and voluntary activation remained depressed (P < 0.05), but the resting twitch had returned to baseline (P > 0.05) with no sex differences. Central mechanisms were primarily responsible for the depressed maximal force production up to 48 h after repeated eccentric contractions of the knee extensors and these mechanisms were similar in men and women.

  7. Ingestion of High Molecular Weight Carbohydrate Enhances Subsequent Repeated Maximal Power: A Randomized Controlled Trial

    PubMed Central

    Oliver, Jonathan M.; Almada, Anthony L.; Van Eck, Leighsa E.; Shah, Meena; Mitchell, Joel B.; Jones, Margaret T.; Jagim, Andrew R.; Rowlands, David S.

    2016-01-01

    Athletes in sports demanding repeat maximal work outputs frequently train concurrently utilizing sequential bouts of intense endurance and resistance training sessions. On a daily basis, maximal work within subsequent bouts may be limited by muscle glycogen availability. Recently, the ingestion of a unique high molecular weight (HMW) carbohydrate was found to increase glycogen re-synthesis rate and enhance work output during subsequent endurance exercise, relative to low molecular weight (LMW) carbohydrate ingestion. The effect of the HMW carbohydrate, however, on the performance of intense resistance exercise following prolonged-intense endurance training is unknown. Sixteen resistance trained men (23±3 years; 176.7±9.8 cm; 88.2±8.6 kg) participated in a double-blind, placebo-controlled, randomized 3-way crossover design comprising a muscle-glycogen depleting cycling exercise followed by ingestion of placebo (PLA), or 1.2 g•kg•bw-1 of LMW or HMW carbohydrate solution (10%) with blood sampling for 2-h post-ingestion. Thereafter, participants performed 5 sets of 10 maximal explosive repetitions of back squat (75% of 1RM). Compared to PLA, ingestion of HMW (4.9%, 90%CI 3.8%, 5.9%) and LMW (1.9%, 90%CI 0.8%, 3.0%) carbohydrate solutions substantially increased power output during resistance exercise, with the 3.1% (90% CI 4.3, 2.0%) almost certain additional gain in power after HMW-LMW ingestion attributed to higher movement velocity after force kinematic analysis (HMW-LMW 2.5%, 90%CI 1.4, 3.7%). Both carbohydrate solutions increased post-exercise plasma glucose, glucoregulatory and gut hormones compared to PLA, but differences between carbohydrates were unclear; thus, the underlying mechanism remains to be elucidated. Ingestion of a HMW carbohydrate following prolonged intense endurance exercise provides superior benefits to movement velocity and power output during subsequent repeated maximal explosive resistance exercise. This study was registered with clinicaltrials.gov (NCT02778373). PMID:27636206

  8. Ingestion of High Molecular Weight Carbohydrate Enhances Subsequent Repeated Maximal Power: A Randomized Controlled Trial.

    PubMed

    Oliver, Jonathan M; Almada, Anthony L; Van Eck, Leighsa E; Shah, Meena; Mitchell, Joel B; Jones, Margaret T; Jagim, Andrew R; Rowlands, David S

    2016-01-01

    Athletes in sports demanding repeat maximal work outputs frequently train concurrently utilizing sequential bouts of intense endurance and resistance training sessions. On a daily basis, maximal work within subsequent bouts may be limited by muscle glycogen availability. Recently, the ingestion of a unique high molecular weight (HMW) carbohydrate was found to increase glycogen re-synthesis rate and enhance work output during subsequent endurance exercise, relative to low molecular weight (LMW) carbohydrate ingestion. The effect of the HMW carbohydrate, however, on the performance of intense resistance exercise following prolonged-intense endurance training is unknown. Sixteen resistance trained men (23±3 years; 176.7±9.8 cm; 88.2±8.6 kg) participated in a double-blind, placebo-controlled, randomized 3-way crossover design comprising a muscle-glycogen depleting cycling exercise followed by ingestion of placebo (PLA), or 1.2 g•kg•bw-1 of LMW or HMW carbohydrate solution (10%) with blood sampling for 2-h post-ingestion. Thereafter, participants performed 5 sets of 10 maximal explosive repetitions of back squat (75% of 1RM). Compared to PLA, ingestion of HMW (4.9%, 90%CI 3.8%, 5.9%) and LMW (1.9%, 90%CI 0.8%, 3.0%) carbohydrate solutions substantially increased power output during resistance exercise, with the 3.1% (90% CI 4.3, 2.0%) almost certain additional gain in power after HMW-LMW ingestion attributed to higher movement velocity after force kinematic analysis (HMW-LMW 2.5%, 90%CI 1.4, 3.7%). Both carbohydrate solutions increased post-exercise plasma glucose, glucoregulatory and gut hormones compared to PLA, but differences between carbohydrates were unclear; thus, the underlying mechanism remains to be elucidated. Ingestion of a HMW carbohydrate following prolonged intense endurance exercise provides superior benefits to movement velocity and power output during subsequent repeated maximal explosive resistance exercise. This study was registered with clinicaltrials.gov (NCT02778373).

  9. Ignition in tokamaks with modulated source of auxiliary heating

    NASA Astrophysics Data System (ADS)

    Morozov, D. Kh

    2017-12-01

    It is shown that the ignition may be achieved in tokamaks with the modulated power source. The time-averaged source power may be smaller than the steady-state source power, which is sufficient for the ignition. Nevertheless, the maximal power must be large enough, because the ignition must be achieved within a finite time interval.

  10. Effects of soluble milk protein or casein supplementation on muscle fatigue following resistance training program: a randomized, double-blind, and placebo-controlled study

    PubMed Central

    2014-01-01

    Background The effects of protein supplementation on muscle thickness, strength and fatigue seem largely dependent on its composition. The current study compared the effects of soluble milk protein, micellar casein, and a placebo on strength and fatigue during and after a resistance training program. Methods Sixty-eight physically active men participated in this randomized controlled trial and underwent 10 weeks of lower-body resistance training. Participants were randomly assigned to the Placebo (PLA), Soluble Milk Protein (SMP, with fast digestion rate) or Micellar Casein (MC, with slow digestion rate) group. During the 10-week training period, participants were instructed to take 30 g of the placebo or protein twice a day, or three times on training days. Tests were performed on quadriceps muscles at inclusion (PRE), after 4 weeks (MID) and after 10 weeks (POST) of training. They included muscle endurance (maximum number of repetitions during leg extensions using 70% of the individual maximal load), fatigue (decrease in muscle power after the endurance test), strength, power and muscle thickness. Results Muscle fatigue was significantly lower (P < 0.05) in the SMP group at MID and POST (-326.8 ± 114.1 W and -296.6 ± 130.1 W, respectively) as compared with PLA (-439.2 ± 153.9 W and -479.2 ± 138.1 W, respectively) and MC (-415.1 ± 165.1 W and -413.7 ± 139.4 W, respectively). Increases in maximal muscle power, strength, endurance and thickness were not statistically different between groups. Conclusions The present study demonstrated that protein composition has a large influence on muscular performance after prolonged resistance training. More specifically, as compared with placebo or micellar casein, soluble milk protein (fast digestible) appeared to significantly reduce muscle fatigue induced by intense resistance exercise. PMID:25057266

  11. Effects of soluble milk protein or casein supplementation on muscle fatigue following resistance training program: a randomized, double-blind, and placebo-controlled study.

    PubMed

    Babault, Nicolas; Deley, Gaëlle; Le Ruyet, Pascale; Morgan, François; Allaert, François André

    2014-01-01

    The effects of protein supplementation on muscle thickness, strength and fatigue seem largely dependent on its composition. The current study compared the effects of soluble milk protein, micellar casein, and a placebo on strength and fatigue during and after a resistance training program. Sixty-eight physically active men participated in this randomized controlled trial and underwent 10 weeks of lower-body resistance training. Participants were randomly assigned to the Placebo (PLA), Soluble Milk Protein (SMP, with fast digestion rate) or Micellar Casein (MC, with slow digestion rate) group. During the 10-week training period, participants were instructed to take 30 g of the placebo or protein twice a day, or three times on training days. Tests were performed on quadriceps muscles at inclusion (PRE), after 4 weeks (MID) and after 10 weeks (POST) of training. They included muscle endurance (maximum number of repetitions during leg extensions using 70% of the individual maximal load), fatigue (decrease in muscle power after the endurance test), strength, power and muscle thickness. Muscle fatigue was significantly lower (P < 0.05) in the SMP group at MID and POST (-326.8 ± 114.1 W and -296.6 ± 130.1 W, respectively) as compared with PLA (-439.2 ± 153.9 W and -479.2 ± 138.1 W, respectively) and MC (-415.1 ± 165.1 W and -413.7 ± 139.4 W, respectively). Increases in maximal muscle power, strength, endurance and thickness were not statistically different between groups. The present study demonstrated that protein composition has a large influence on muscular performance after prolonged resistance training. More specifically, as compared with placebo or micellar casein, soluble milk protein (fast digestible) appeared to significantly reduce muscle fatigue induced by intense resistance exercise.

  12. Optimized methods for epilepsy therapy development using an etiologically realistic model of focal epilepsy in the rat

    PubMed Central

    Eastman, Clifford L.; Fender, Jason S.; Temkin, Nancy R.; D’Ambrosio, Raimondo

    2015-01-01

    Conventionally developed antiseizure drugs fail to control epileptic seizures in about 30% of patients, and no treatment prevents epilepsy. New etiologically realistic, syndrome-specific epilepsy models are expected to identify better treatments by capturing currently unknown ictogenic and epileptogenic mechanisms that operate in the corresponding patient populations. Additionally, the use of electrocorticography permits better monitoring of epileptogenesis and the full spectrum of acquired seizures, including focal nonconvulsive seizures that are typically difficult to treat in humans. Thus, the combined use of etiologically realistic models and electrocorticography may improve our understanding of the genesis and progression of epilepsy, and facilitate discovery and translation of novel treatments. However, this approach is labor intensive and must be optimized. To this end, we used an etiologically realistic rat model of posttraumatic epilepsy, in which the initiating fluid percussion injury closely replicates contusive closed-head injury in humans, and has been adapted to maximize epileptogenesis and focal non-convulsive seizures. We obtained week-long 5-electrode electrocorticography 1 month post-injury, and used a Monte-Carlo-based non-parametric bootstrap strategy to test the impact of electrode montage design, duration-based seizure definitions, group size and duration of recordings on the assessment of posttraumatic epilepsy, and on statistical power to detect antiseizure and antiepileptogenic treatment effects. We found that use of seizure definition based on clinical criteria rather than event duration, and of recording montages closely sampling the activity of epileptic foci, maximize the power to detect treatment effects. Detection of treatment effects was marginally improved by prolonged recording, and 24 h recording epochs were sufficient to provide 80% power to detect clinically interesting seizure control or prevention of seizures with small groups of animals. We conclude that appropriate electrode montage and clinically relevant seizure definition permit convenient deployment of fluid percussion injury and electrocorticography for epilepsy therapy development. PMID:25523813

  13. Network efficient power control for wireless communication systems.

    PubMed

    Campos-Delgado, Daniel U; Luna-Rivera, Jose Martin; Martinez-Sánchez, C J; Gutierrez, Carlos A; Tecpanecatl-Xihuitl, J L

    2014-01-01

    We introduce a two-loop power control that allows an efficient use of the overall power resources for commercial wireless networks based on cross-layer optimization. This approach maximizes the network's utility in the outer-loop as a function of the averaged signal to interference-plus-noise ratio (SINR) by considering adaptively the changes in the network characteristics. For this purpose, the concavity property of the utility function was verified with respect to the SINR, and an iterative search was proposed with guaranteed convergence. In addition, the outer-loop is in charge of selecting the detector that minimizes the overall power consumption (transmission and detection). Next the inner-loop implements a feedback power control in order to achieve the optimal SINR in the transmissions despite channel variations and roundtrip delays. In our proposal, the utility maximization process and detector selection and feedback power control are decoupled problems, and as a result, these strategies are implemented at two different time scales in the two-loop framework. Simulation results show that substantial utility gains may be achieved by improving the power management in the wireless network.

  14. Network Efficient Power Control for Wireless Communication Systems

    PubMed Central

    Campos-Delgado, Daniel U.; Luna-Rivera, Jose Martin; Martinez-Sánchez, C. J.; Gutierrez, Carlos A.; Tecpanecatl-Xihuitl, J. L.

    2014-01-01

    We introduce a two-loop power control that allows an efficient use of the overall power resources for commercial wireless networks based on cross-layer optimization. This approach maximizes the network's utility in the outer-loop as a function of the averaged signal to interference-plus-noise ratio (SINR) by considering adaptively the changes in the network characteristics. For this purpose, the concavity property of the utility function was verified with respect to the SINR, and an iterative search was proposed with guaranteed convergence. In addition, the outer-loop is in charge of selecting the detector that minimizes the overall power consumption (transmission and detection). Next the inner-loop implements a feedback power control in order to achieve the optimal SINR in the transmissions despite channel variations and roundtrip delays. In our proposal, the utility maximization process and detector selection and feedback power control are decoupled problems, and as a result, these strategies are implemented at two different time scales in the two-loop framework. Simulation results show that substantial utility gains may be achieved by improving the power management in the wireless network. PMID:24683350

  15. Utilizing Maximum Power Point Trackers in Parallel to Maximize the Power Output of a Solar (Photovoltaic) Array

    DTIC Science & Technology

    2012-12-01

    photovoltaic (PV) system to use a maximum power point tracker ( MPPT ) to increase... photovoltaic (PV) system to use a maximum power point tracker ( MPPT ) to increase the power output of the solar array. Currently, most military... MPPT ) is an optimizing circuit that is used in conjunction with photovoltaic (PV) arrays to achieve the maximum delivery of power from the array

  16. Power maximization of variable-speed variable-pitch wind turbines using passive adaptive neural fault tolerant control

    NASA Astrophysics Data System (ADS)

    Habibi, Hamed; Rahimi Nohooji, Hamed; Howard, Ian

    2017-09-01

    Power maximization has always been a practical consideration in wind turbines. The question of how to address optimal power capture, especially when the system dynamics are nonlinear and the actuators are subject to unknown faults, is significant. This paper studies the control methodology for variable-speed variable-pitch wind turbines including the effects of uncertain nonlinear dynamics, system fault uncertainties, and unknown external disturbances. The nonlinear model of the wind turbine is presented, and the problem of maximizing extracted energy is formulated by designing the optimal desired states. With the known system, a model-based nonlinear controller is designed; then, to handle uncertainties, the unknown nonlinearities of the wind turbine are estimated by utilizing radial basis function neural networks. The adaptive neural fault tolerant control is designed passively to be robust on model uncertainties, disturbances including wind speed and model noises, and completely unknown actuator faults including generator torque and pitch actuator torque. The Lyapunov direct method is employed to prove that the closed-loop system is uniformly bounded. Simulation studies are performed to verify the effectiveness of the proposed method.

  17. Clustering and Beamforming for Efficient Communication in Wireless Sensor Networks

    PubMed Central

    Porcel-Rodríguez, Francisco; Valenzuela-Valdés, Juan; Padilla, Pablo; Luna-Valero, Francisco; Luque-Baena, Rafael; López-Gordo, Miguel Ángel

    2016-01-01

    Energy efficiency is a critical issue for wireless sensor networks (WSNs) as sensor nodes have limited power availability. In order to address this issue, this paper tries to maximize the power efficiency in WSNs by means of the evaluation of WSN node networks and their performance when both clustering and antenna beamforming techniques are applied. In this work, four different scenarios are defined, each one considering different numbers of sensors: 50, 20, 10, five, and two nodes per scenario, and each scenario is randomly generated thirty times in order to statistically validate the results. For each experiment, two different target directions for transmission are taken into consideration in the optimization process (φ = 0° and θ = 45°; φ = 45°, and θ = 45°). Each scenario is evaluated for two different types of antennas, an ideal isotropic antenna and a conventional dipole one. In this set of experiments two types of WSN are evaluated: in the first one, all of the sensors have the same amount of power for communications purposes; in the second one, each sensor has a different amount of power for its communications purposes. The analyzed cases in this document are focused on 2D surface and 3D space for the node location. To the authors’ knowledge, this is the first time that beamforming and clustering are simultaneously applied to increase the network lifetime in WSNs. PMID:27556463

  18. Evaluating and Reporting Statistical Power in Counseling Research

    ERIC Educational Resources Information Center

    Balkin, Richard S.; Sheperis, Carl J.

    2011-01-01

    Despite recommendations from the "Publication Manual of the American Psychological Association" (6th ed.) to include information on statistical power when publishing quantitative results, authors seldom include analysis or discussion of statistical power. The rationale for discussing statistical power is addressed, approaches to using "G*Power" to…

  19. Stability region maximization by decomposition-aggregation method. [Skylab stability

    NASA Technical Reports Server (NTRS)

    Siljak, D. D.; Cuk, S. M.

    1974-01-01

    This work is to improve the estimates of the stability regions by formulating and resolving a proper maximization problem. The solution of the problem provides the best estimate of the maximal value of the structural parameter and at the same time yields the optimum comparison system, which can be used to determine the degree of stability of the Skylab. The analysis procedure is completely computerized, resulting in a flexible and powerful tool for stability considerations of large-scale linear as well as nonlinear systems.

  20. Combinatorial interpretation of Haldane-Wu fractional exclusion statistics.

    PubMed

    Aringazin, A K; Mazhitov, M I

    2002-08-01

    Assuming that the maximal allowed number of identical particles in a state is an integer parameter, q, we derive the statistical weight and analyze the associated equation that defines the statistical distribution. The derived distribution covers Fermi-Dirac and Bose-Einstein ones in the particular cases q=1 and q--> infinity (n(i)/q-->1), respectively. We show that the derived statistical weight provides a natural combinatorial interpretation of Haldane-Wu fractional exclusion statistics, and present exact solutions of the distribution equation.

  1. Importance of upper-limb inertia in calculating concentric bench press force.

    PubMed

    Rambaud, Olivier; Rahmani, Abderrahmane; Moyen, Bernard; Bourdin, Muriel

    2008-03-01

    The purpose of this study was to investigate the influence of upper-limb inertia on the force-velocity relationship and maximal power during concentric bench press exercise. Reference peak force values (Fpeakp) measured with a force plate positioned below the bench were compared to those measured simultaneously with a kinematic device fixed on the barbell by taking (Fpeakt) or not taking (Fpeakb) upper-limb inertia into account. Thirteen men (27.8 +/- 4.1 years, 184.6 +/- 5.5 cm, 99.5 +/- 18.6 kg) performed all-out concentric bench press exercise against 8 loads ranging between 7 and 74 kg. The results showed that for each load, Fpeakb was significantly less than Fpeakp (P < 0.0001), whereas no significant difference was found between Fpeakp and Fpeakt. The values of maximal force (F0), maximal velocity (V0), optimal velocity (Vopt), and maximal power (Pmax), extrapolated from the force- and power-velocity relationships determined with the kinematic device, were significantly underestimated when upper-limb inertia was ignored. The results underline the importance of taking account of the total inertia of the moving system to ensure precise evaluation of upper-limb muscular characteristics in all-out concentric bench press exercise with a kinematic device. A major application of this study would be to develop precise upper-limb muscular characteristic evaluation in laboratory and field conditions by using a simple and cheap kinematic device.

  2. High-intensity and resistance training and elite young athletes.

    PubMed

    Ratel, Sébastien

    2011-01-01

    Although in the past resistance and high-intensity exercise training among young children was the subject of numerous controversies, it is now well-documented that this training mode is a safe and effective means of developing maximal strength, maximal power output and athletic performance in youth, provided that exercises are performed with appropriate supervision and precautions. Muscular strength and power output values measured from vertical jump and Wingate anaerobic tests are higher in elite than in non-elite young athletes and normal children, and the specific training effects on maximal power output normalised for body size are clearly more distinct before puberty. At present, there is no scientific evidence to support the view that high-intensity and/or resistance training might hinder growth and maturation in young children. Pre-pubertal growth is not adversely affected by sport at a competitive level and anthropometric factors are of importance for choice of sport in children. However, coaches, teachers and parents should be aware that unsupervised high-intensity and resistance training programmes involving maximal loads or too frequently repeated resistance exercises increase the risk of injury. Resistance training alone is an effective additional means of developing athletic performance throughout planned youth sports training programmes. Strategies for enhancing the effectiveness and safety of youth resistance and high-intensity exercise training are discussed in this chapter. Copyright © 2011 S. Karger AG, Basel.

  3. The Impacts of Wind Speed Trends and Long-term Variability in Relation to Hydroelectric Reservoir Inflows on Wind Power in the Pacific Northwest

    NASA Astrophysics Data System (ADS)

    Cross, B.; Kohfeld, K. E.; Cooper, A.; Bailey, H. J.; Rucker, M.

    2013-12-01

    The use of wind power is growing rapidly in the Pacific Northwest (PNW ) due to environmental concerns, decreasing costs of implementation, strong wind speeds, and a desire to diversify electricity sources to minimize the impacts of streamflow variability on electricity prices and system flexibility. In hydroelectric dominated systems, like the PNW, the benefits of wind power can be maximized by accounting for the relationship between long term variability in wind speeds and reservoir inflows. Clean energy policies in British Columbia make the benefits of increased wind power generation during low streamflow periods particularly large, by preventing the overbuilding of marginal hydroelectric projects. The goal of this work was to quantify long-term relationships between wind speed and streamflow behavior in British Columbia. Wind speed data from the North American Regional Reanalysis (NARR) and cumulative usable inflows (CUI) from BC Hydro were used to analyze 10m wind speed and density (WD) trends, WD-CUI correlations, and WD anomalies during low and high inflow periods in the PNW (40°N to 65°N, 110°W to 135°W) from 1979-2010. Statistically significant positive wind speed and density trends were found for most of the PNW, with the largest increases along the Pacific Coast. CUI-WD correlations were weakly positive for most regions, with the highest values along the US coast (r ~0.55), generally weaker correlations to the north, and negative correlations (r ~ -0.25) along BC's North Coast. When considering seasonal relationships, the Spring freshet was coincident with lower WD anomalies west of the Rocky Mountains and higher WDs to the east. A similar but opposite pattern was observed for low inflow winter months. When considering interannual variability, lowest inflow years experienced positive WD anomalies (up to 40% increases) for the North Coast. In highest inflow years, positive WD anomalies were widespread in the US and for smaller patches of central BC. By accounting for regional and temporal differences in the relationship between wind (WD) and streamflow (CUI) behaviour during wind farm site selection, the benefits of energy diversification can be maximized.

  4. 10-year changes in upper body strength and power in elite professional rugby league players--the effect of training age, stage, and content.

    PubMed

    Baker, Daniel G

    2013-02-01

    The purpose of this investigation was to observe changes in maximal upper body strength and power across a 10-year period in professional athletes who were experienced resistance trainers. Six professional rugby league players were observed with test data reported according to 2 important training stages in their professional careers. The first stage (1996-1998) monitored the changes as the subjects strived to establish themselves as elite professionals in their sport. The remaining test data are from the latter stage (2000-2006), which is characterized by a longer competition schedule and shorter periods devoted to improving physical preparation. The changes in upper body strength, assessed by the 1 repetition maximum bench press and mean maximum power during bench press throws with various barbell resistances of 40-80 kg, were assessed by effect size (ES) and smallest worthwhile change (SWC) statistics. Large increases in strength and power of approximately 22-23% were reported across the 10-year period, however, only small changes (as determined by ES) in strength or power occurred after year 2000 till 2006. This result of only small changes in strength or power despite 6 years of intense resistance training was attributed to 3 main factors. Key among them are the possible existence of a "strength ceiling" for experienced resistance trainers, the Long-term Athlete Development model, and possibly an inappropriate volume of strength-endurance training from 2004 to 2005. The fact that an SWC in strength and power occurred in the year after the cessation of strength-endurance training suggests that training program manipulation is still an influencing factor in continuing strength and power gains in experienced resistance trainers.

  5. Fatigue and recovery from dynamic contractions in men and women differ for arm and leg muscles.

    PubMed

    Senefeld, Jonathon; Yoon, Tejin; Bement, Marie Hoeger; Hunter, Sandra K

    2013-09-01

    Whether there is a gender difference in fatigue and recovery from maximal velocity fatiguing contractions and across muscles is not understood. Sixteen men and 19 women performed 90 isotonic contractions at maximal voluntary shortening velocity (maximal velocity concentric contractions, MVCC) with the elbow flexor and knee extensor muscles (separate days) at a load equivalent to 20% maximal voluntary isometric contraction (MVIC). Power (from MVCCs) decreased similarly for men and women for both muscles (P > 0.05). Men and women had similar declines in MVIC of elbow flexors, but men had greater reductions in knee extensor MVIC force and MVIC electromyogram activity than women (P < 0.05). The decline in MVIC and power was greater, and force recovery was slower for the elbow flexors compared with knee extensors. The gender difference in muscle fatigue often observed during isometric tasks was diminished during fast dynamic contractions for upper and lower limb muscles. Copyright © Published 2013 by Wiley Periodicals, Inc. This article is a US Government wmusork and, as such, is in the public domain in the United States of America.

  6. Power-up: A Reanalysis of 'Power Failure' in Neuroscience Using Mixture Modeling.

    PubMed

    Nord, Camilla L; Valton, Vincent; Wood, John; Roiser, Jonathan P

    2017-08-23

    Recently, evidence for endemically low statistical power has cast neuroscience findings into doubt. If low statistical power plagues neuroscience, then this reduces confidence in the reported effects. However, if statistical power is not uniformly low, then such blanket mistrust might not be warranted. Here, we provide a different perspective on this issue, analyzing data from an influential study reporting a median power of 21% across 49 meta-analyses (Button et al., 2013). We demonstrate, using Gaussian mixture modeling, that the sample of 730 studies included in that analysis comprises several subcomponents so the use of a single summary statistic is insufficient to characterize the nature of the distribution. We find that statistical power is extremely low for studies included in meta-analyses that reported a null result and that it varies substantially across subfields of neuroscience, with particularly low power in candidate gene association studies. Therefore, whereas power in neuroscience remains a critical issue, the notion that studies are systematically underpowered is not the full story: low power is far from a universal problem. SIGNIFICANCE STATEMENT Recently, researchers across the biomedical and psychological sciences have become concerned with the reliability of results. One marker for reliability is statistical power: the probability of finding a statistically significant result given that the effect exists. Previous evidence suggests that statistical power is low across the field of neuroscience. Our results present a more comprehensive picture of statistical power in neuroscience: on average, studies are indeed underpowered-some very seriously so-but many studies show acceptable or even exemplary statistical power. We show that this heterogeneity in statistical power is common across most subfields in neuroscience. This new, more nuanced picture of statistical power in neuroscience could affect not only scientific understanding, but potentially policy and funding decisions for neuroscience research. Copyright © 2017 Nord, Valton et al.

  7. High-repetition-rate widely tunable LiF : \\mathbf{\\mathsf{F}}_\\mathbf{\\mathsf{2}}^{-} color center lasers

    NASA Astrophysics Data System (ADS)

    Men, Shaojie; Liu, Zhaojun; Cong, Zhenhua; Rao, Han; Zhang, Sasa; Liu, Yang; Zverev, Petr G.; Konyushkin, Vasily A.; Zhang, Xingyu

    2016-02-01

    High-repetition-rate tunable LiF:\\text{F}2- color center lasers pumped by quasi-continuous-wave diode-side-pumped acousto-optically Q-switched Nd:YAG laser are demonstrated. Littrow-grating and Littman-grating tuning schemes are studied respectively. In the Littrow-grating scheme, the tuning range was 1085 nm to 1275 nm, and the maximal average output power was 275 mW. In the Littman-grating scheme, the tuning range was 1105.5 nm to 1215.5 nm, and the maximal average output power was 135 mW.

  8. Multivariate regression methods for estimating velocity of ictal discharges from human microelectrode recordings

    NASA Astrophysics Data System (ADS)

    Liou, Jyun-you; Smith, Elliot H.; Bateman, Lisa M.; McKhann, Guy M., II; Goodman, Robert R.; Greger, Bradley; Davis, Tyler S.; Kellis, Spencer S.; House, Paul A.; Schevon, Catherine A.

    2017-08-01

    Objective. Epileptiform discharges, an electrophysiological hallmark of seizures, can propagate across cortical tissue in a manner similar to traveling waves. Recent work has focused attention on the origination and propagation patterns of these discharges, yielding important clues to their source location and mechanism of travel. However, systematic studies of methods for measuring propagation are lacking. Approach. We analyzed epileptiform discharges in microelectrode array recordings of human seizures. The array records multiunit activity and local field potentials at 400 micron spatial resolution, from a small cortical site free of obstructions. We evaluated several computationally efficient statistical methods for calculating traveling wave velocity, benchmarking them to analyses of associated neuronal burst firing. Main results. Over 90% of discharges met statistical criteria for propagation across the sampled cortical territory. Detection rate, direction and speed estimates derived from a multiunit estimator were compared to four field potential-based estimators: negative peak, maximum descent, high gamma power, and cross-correlation. Interestingly, the methods that were computationally simplest and most efficient (negative peak and maximal descent) offer non-inferior results in predicting neuronal traveling wave velocities compared to the other two, more complex methods. Moreover, the negative peak and maximal descent methods proved to be more robust against reduced spatial sampling challenges. Using least absolute deviation in place of least squares error minimized the impact of outliers, and reduced the discrepancies between local field potential-based and multiunit estimators. Significance. Our findings suggest that ictal epileptiform discharges typically take the form of exceptionally strong, rapidly traveling waves, with propagation detectable across millimeter distances. The sequential activation of neurons in space can be inferred from clinically-observable EEG data, with a variety of straightforward computation methods available. This opens possibilities for systematic assessments of ictal discharge propagation in clinical and research settings.

  9. Effect of Aerobic Exercise Training on Ventilatory Efficiency and Respiratory Drive in Obese Subjects.

    PubMed

    Chlif, Mehdi; Chaouachi, Anis; Ahmaidi, Said

    2017-07-01

    Obese patients show a decline in exercise capacity and diverse degrees of dyspnea in association with mechanical abnormalities, increased ventilatory requirements secondary to the increased metabolic load, and a greater work of breathing. Consequently, obese patients may be particularly predisposed to the development of respiratory muscle fatigue during exercise. The aim of this study was to assess inspiratory muscle performance during incremental exercise in 19 obese male subjects (body mass index 41 ± 6 kg/m 2 ) after aerobic exercise training using the noninvasive, inspiratory muscle tension-time index (T T0.1 ). Measurements performed included anthropometric parameters, lung function assessed by spirometry, rate of perceived breathlessness with the modified Borg dyspnea scale (0-10), breathing pattern, maximal exercise capacity, and inspiratory muscle performance with a breath-by-breath automated exercise metabolic system during an incremental exercise test. T T0.1 was calculated using the equation, T T0.1 = P 0.1 /P Imax × T I /T tot (where P 0.1 represents mouth occlusion pressure, P Imax is maximal inspiratory pressure, and T I /T tot is the duty cycle). At rest, there was no statistically significant difference for spirometric parameters and cardiorespiratory parameters between pre- and post-training. At maximal exercise, the minute ventilation, the rate of exchange ratio, the rate of perceived breathlessness, and the respiratory muscle performance parameters were not significantly different pre- and post-training; in contrast, tidal volume ( P = .037, effect size = 1.51), breathing frequency ( P = .049, effect size = 0.97), power output ( P = .048, effect size = 0.79), peak oxygen uptake ( P = .02, effect size = 0.92) were significantly higher after training. At comparable work load, training induces lower minute ventilation, mouth occlusion pressure, ratio of occlusion pressure to maximal inspiratory pressure, T T0.1 , and rate of perceived breathlessness. Aerobic exercise at ventilatory threshold can induce significant improvement in respiratory muscle strength, maximal exercise capacity, and inspiratory muscle performance and decreased dyspnea perception in obese subjects. Copyright © 2017 by Daedalus Enterprises.

  10. Tripartite-to-Bipartite Entanglement Transformation by Stochastic Local Operations and Classical Communication and the Structure of Matrix Spaces

    NASA Astrophysics Data System (ADS)

    Li, Yinan; Qiao, Youming; Wang, Xin; Duan, Runyao

    2018-03-01

    We study the problem of transforming a tripartite pure state to a bipartite one using stochastic local operations and classical communication (SLOCC). It is known that the tripartite-to-bipartite SLOCC convertibility is characterized by the maximal Schmidt rank of the given tripartite state, i.e. the largest Schmidt rank over those bipartite states lying in the support of the reduced density operator. In this paper, we further study this problem and exhibit novel results in both multi-copy and asymptotic settings, utilizing powerful results from the structure of matrix spaces. In the multi-copy regime, we observe that the maximal Schmidt rank is strictly super-multiplicative, i.e. the maximal Schmidt rank of the tensor product of two tripartite pure states can be strictly larger than the product of their maximal Schmidt ranks. We then provide a full characterization of those tripartite states whose maximal Schmidt rank is strictly super-multiplicative when taking tensor product with itself. Notice that such tripartite states admit strict advantages in tripartite-to-bipartite SLOCC transformation when multiple copies are provided. In the asymptotic setting, we focus on determining the tripartite-to-bipartite SLOCC entanglement transformation rate. Computing this rate turns out to be equivalent to computing the asymptotic maximal Schmidt rank of the tripartite state, defined as the regularization of its maximal Schmidt rank. Despite the difficulty caused by the super-multiplicative property, we provide explicit formulas for evaluating the asymptotic maximal Schmidt ranks of two important families of tripartite pure states by resorting to certain results of the structure of matrix spaces, including the study of matrix semi-invariants. These formulas turn out to be powerful enough to give a sufficient and necessary condition to determine whether a given tripartite pure state can be transformed to the bipartite maximally entangled state under SLOCC, in the asymptotic setting. Applying the recent progress on the non-commutative rank problem, we can verify this condition in deterministic polynomial time.

  11. BAYESIAN SEMI-BLIND COMPONENT SEPARATION FOR FOREGROUND REMOVAL IN INTERFEROMETRIC 21 cm OBSERVATIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Le; Timbie, Peter T.; Bunn, Emory F.

    In this paper, we present a new Bayesian semi-blind approach for foreground removal in observations of the 21 cm signal measured by interferometers. The technique, which we call H i Expectation–Maximization Independent Component Analysis (HIEMICA), is an extension of the Independent Component Analysis technique developed for two-dimensional (2D) cosmic microwave background maps to three-dimensional (3D) 21 cm cosmological signals measured by interferometers. This technique provides a fully Bayesian inference of power spectra and maps and separates the foregrounds from the signal based on the diversity of their power spectra. Relying only on the statistical independence of the components, this approachmore » can jointly estimate the 3D power spectrum of the 21 cm signal, as well as the 2D angular power spectrum and the frequency dependence of each foreground component, without any prior assumptions about the foregrounds. This approach has been tested extensively by applying it to mock data from interferometric 21 cm intensity mapping observations under idealized assumptions of instrumental effects. We also discuss the impact when the noise properties are not known completely. As a first step toward solving the 21 cm power spectrum analysis problem, we compare the semi-blind HIEMICA technique to the commonly used Principal Component Analysis. Under the same idealized circumstances, the proposed technique provides significantly improved recovery of the power spectrum. This technique can be applied in a straightforward manner to all 21 cm interferometric observations, including epoch of reionization measurements, and can be extended to single-dish observations as well.« less

  12. Simplified power control method for cellular mobile communication

    NASA Astrophysics Data System (ADS)

    Leung, Y. W.

    1994-04-01

    The centralized power control (CPC) method measures the gain of the communication links between every mobile and every base station in the cochannel cells and determines optimal transmitter power to maximize the minimum carrier-to-interference ratio. The authors propose a simplified power control method which has nearly the same performance as the CPC method but which involves much smaller measurement overhead.

  13. Statistics of optimal information flow in ensembles of regulatory motifs

    NASA Astrophysics Data System (ADS)

    Crisanti, Andrea; De Martino, Andrea; Fiorentino, Jonathan

    2018-02-01

    Genetic regulatory circuits universally cope with different sources of noise that limit their ability to coordinate input and output signals. In many cases, optimal regulatory performance can be thought to correspond to configurations of variables and parameters that maximize the mutual information between inputs and outputs. Since the mid-2000s, such optima have been well characterized in several biologically relevant cases. Here we use methods of statistical field theory to calculate the statistics of the maximal mutual information (the "capacity") achievable by tuning the input variable only in an ensemble of regulatory motifs, such that a single controller regulates N targets. Assuming (i) sufficiently large N , (ii) quenched random kinetic parameters, and (iii) small noise affecting the input-output channels, we can accurately reproduce numerical simulations both for the mean capacity and for the whole distribution. Our results provide insight into the inherent variability in effectiveness occurring in regulatory systems with heterogeneous kinetic parameters.

  14. Are the Nonparametric Person-Fit Statistics More Powerful than Their Parametric Counterparts? Revisiting the Simulations in Karabatsos (2003)

    ERIC Educational Resources Information Center

    Sinharay, Sandip

    2017-01-01

    Karabatsos compared the power of 36 person-fit statistics using receiver operating characteristics curves and found the "H[superscript T]" statistic to be the most powerful in identifying aberrant examinees. He found three statistics, "C", "MCI", and "U3", to be the next most powerful. These four statistics,…

  15. Did Babe Ruth Have a Comparative Advantage as a Pitcher?

    ERIC Educational Resources Information Center

    Scahill, Edward M.

    1990-01-01

    Advocates using baseball statistics to illustrate the advantages of specialization in production. Using Babe Ruth's record as an analogy, suggests a methodology for determining a player's comparative advantage as a teaching illustration. Includes the team's statistical profile in five tables to explain comparative advantage and profit maximizing.…

  16. Statistical mechanics of multipartite entanglement

    NASA Astrophysics Data System (ADS)

    Facchi, P.; Florio, G.; Marzolino, U.; Parisi, G.; Pascazio, S.

    2009-02-01

    We characterize the multipartite entanglement of a system of n qubits in terms of the distribution function of the bipartite purity over all balanced bipartitions. We search for those (maximally multipartite entangled) states whose purity is minimum for all bipartitions and recast this optimization problem into a problem of statistical mechanics.

  17. Multi-arm group sequential designs with a simultaneous stopping rule.

    PubMed

    Urach, S; Posch, M

    2016-12-30

    Multi-arm group sequential clinical trials are efficient designs to compare multiple treatments to a control. They allow one to test for treatment effects already in interim analyses and can have a lower average sample number than fixed sample designs. Their operating characteristics depend on the stopping rule: We consider simultaneous stopping, where the whole trial is stopped as soon as for any of the arms the null hypothesis of no treatment effect can be rejected, and separate stopping, where only recruitment to arms for which a significant treatment effect could be demonstrated is stopped, but the other arms are continued. For both stopping rules, the family-wise error rate can be controlled by the closed testing procedure applied to group sequential tests of intersection and elementary hypotheses. The group sequential boundaries for the separate stopping rule also control the family-wise error rate if the simultaneous stopping rule is applied. However, we show that for the simultaneous stopping rule, one can apply improved, less conservative stopping boundaries for local tests of elementary hypotheses. We derive corresponding improved Pocock and O'Brien type boundaries as well as optimized boundaries to maximize the power or average sample number and investigate the operating characteristics and small sample properties of the resulting designs. To control the power to reject at least one null hypothesis, the simultaneous stopping rule requires a lower average sample number than the separate stopping rule. This comes at the cost of a lower power to reject all null hypotheses. Some of this loss in power can be regained by applying the improved stopping boundaries for the simultaneous stopping rule. The procedures are illustrated with clinical trials in systemic sclerosis and narcolepsy. © 2016 The Authors. Statistics in Medicine Published by John Wiley & Sons Ltd. © 2016 The Authors. Statistics in Medicine Published by John Wiley & Sons Ltd.

  18. Statistical Learning Theory for High Dimensional Prediction: Application to Criterion-Keyed Scale Development

    PubMed Central

    Chapman, Benjamin P.; Weiss, Alexander; Duberstein, Paul

    2016-01-01

    Statistical learning theory (SLT) is the statistical formulation of machine learning theory, a body of analytic methods common in “big data” problems. Regression-based SLT algorithms seek to maximize predictive accuracy for some outcome, given a large pool of potential predictors, without overfitting the sample. Research goals in psychology may sometimes call for high dimensional regression. One example is criterion-keyed scale construction, where a scale with maximal predictive validity must be built from a large item pool. Using this as a working example, we first introduce a core principle of SLT methods: minimization of expected prediction error (EPE). Minimizing EPE is fundamentally different than maximizing the within-sample likelihood, and hinges on building a predictive model of sufficient complexity to predict the outcome well, without undue complexity leading to overfitting. We describe how such models are built and refined via cross-validation. We then illustrate how three common SLT algorithms–Supervised Principal Components, Regularization, and Boosting—can be used to construct a criterion-keyed scale predicting all-cause mortality, using a large personality item pool within a population cohort. Each algorithm illustrates a different approach to minimizing EPE. Finally, we consider broader applications of SLT predictive algorithms, both as supportive analytic tools for conventional methods, and as primary analytic tools in discovery phase research. We conclude that despite their differences from the classic null-hypothesis testing approach—or perhaps because of them–SLT methods may hold value as a statistically rigorous approach to exploratory regression. PMID:27454257

  19. Global Wind Map

    ERIC Educational Resources Information Center

    Journal of College Science Teaching, 2005

    2005-01-01

    This brief article describes a new global wind-power map that has quantified global wind power and may help planners place turbines in locations that can maximize power from the winds and provide widely available low-cost energy. The researchers report that their study can assist in locating wind farms in regions known for strong and consistent…

  20. Human Muscle Power Output during Upper- and Lower-Body Exercises.

    ERIC Educational Resources Information Center

    Siegel, Judith A.; Gilders, Roger M.; Staron, Robert S.; Hagerman, Fredrick C.

    2002-01-01

    Evaluated the use of traditional resistance training equipment in measuring muscular power, measuring the velocity of movement through a measured distance during maximal effort lifts using a Smith rack. Data collected on male volunteers indicated that this method of evaluating muscle power was reliable, although it was not predictive of muscle…

  1. The acute effects of moderately loaded concentric-only quarter squats on vertical jump performance.

    PubMed

    Crum, Aaron J; Kawamori, Naoki; Stone, Michael H; Haff, G Gregory

    2012-04-01

    Limited research exists examining the effect of moderately loaded conditioning activities that are employed as part of a strength-power potentiating complex (SPPC). Additionally, no studies to date have explored the effects of using a concentric-only quarter back squat protocol as part of an SPPC. Therefore, the purpose of this study was to examine the effects of a moderately loaded (50-65% of 1RM) concentric-only quarter back squat protocol on the occurrence of potentiation effects at various time points. Twenty men who could quarter back squat a minimum of 2.4 times their body mass (3.7 ± 0.7 kg·per body mass) participated in this investigation. All subjects participated in 3 conditions: control (CT), a 50% of 1RM trial (50POT), and a 65% of 1RM trial (65POT). One minute before each condition, a maximal countermovement vertical jump (CMJ) was performed. One minute later, the subject performed 1 of 3 conditions: CT condition, 50POT, or 65POT, followed by vertical jumps at 0.5, 3, 5, 10, and 15 minutes after conditioning activity. A force plate was used to quantify displacement, peak power output, peak force, and the rate of force development for each CMJ. There were no significant differences (p > 0.05) in any of the performance measures quantified during the CMJ trials when comparing the CT, 50POT, and 65POT treatment conditions. However, 48% of the subjects demonstrated some degree of potentiation at the 30 seconds after completing the 65POT trial, but this percent increase was not statistically significant. From a practical perspective, if the goal of the SPPC is to create a maximization of the potentiation effect, moderately loaded activities may not be the best alternative.

  2. Architectures for wrist-worn energy harvesting

    NASA Astrophysics Data System (ADS)

    Rantz, R.; Halim, M. A.; Xue, T.; Zhang, Q.; Gu, L.; Yang, K.; Roundy, S.

    2018-04-01

    This paper reports the simulation-based analysis of six dynamical structures with respect to their wrist-worn vibration energy harvesting capability. This work approaches the problem of maximizing energy harvesting potential at the wrist by considering multiple mechanical substructures; rotational and linear motion-based architectures are examined. Mathematical models are developed and experimentally corroborated. An optimization routine is applied to the proposed architectures to maximize average power output and allow for comparison. The addition of a linear spring element to the structures has the potential to improve power output; for example, in the case of rotational structures, a 211% improvement in power output was estimated under real walking excitation. The analysis concludes that a sprung rotational harvester architecture outperforms a sprung linear architecture by 66% when real walking data is used as input to the simulations.

  3. Design and Optimization of Ultrasonic Wireless Power Transmission Links for Millimeter-Sized Biomedical Implants.

    PubMed

    Meng, Miao; Kiani, Mehdi

    2017-02-01

    Ultrasound has been recently proposed as an alternative modality for efficient wireless power transmission (WPT) to biomedical implants with millimeter (mm) dimensions. This paper presents the theory and design methodology of ultrasonic WPT links that involve mm-sized receivers (Rx). For given load (R L ) and powering distance (d), the optimal geometries of transmitter (Tx) and Rx ultrasonic transducers, including their diameter and thickness, as well as the optimal operation frequency (f c ) are found through a recursive design procedure to maximize the power transmission efficiency (PTE). First, a range of realistic f c s is found based on the Rx thickness constrain. For a chosen f c within the range, the diameter and thickness of the Rx transducer are then swept together to maximize PTE. Then, the diameter and thickness of the Tx transducer are optimized to maximize PTE. Finally, this procedure is repeated for different f c s to find the optimal f c and its corresponding transducer geometries that maximize PTE. A design example of ultrasonic link has been presented and optimized for WPT to a 1 mm 3 implant, including a disk-shaped piezoelectric transducer on a silicon die. In simulations, a PTE of 2.11% at f c of 1.8 MHz was achieved for R L of 2.5 [Formula: see text] at [Formula: see text]. In order to validate our simulations, an ultrasonic link was optimized for a 1 mm 3 piezoelectric transducer mounted on a printed circuit board (PCB), which led to simulated and measured PTEs of 0.65% and 0.66% at f c of 1.1 MHz for R L of 2.5 [Formula: see text] at [Formula: see text], respectively.

  4. The leveling-off of oxygen uptake is related to blood lactate accumulation. Retrospective study of 94 elite rowers.

    PubMed

    Lacour, Jean-René; Messonnier, Laurent; Bourdin, Muriel

    2007-09-01

    To assess whether the ability to demonstrate a plateau in oxygen consumption VO2 could be related to adaptation to exercise, the data obtained over a period of 10 years on 94 elite oarsmen who had participated in annual testing were re-evaluated. The test consisted in an incremental step protocol until volitional exhaustion. VO2, heart rate (HR), blood lactate ([La]b) and respiratory exchange ratio (RER) were measured at each step. The maximal oxygen consumption (VO2max), the power corresponding to VO2maxPamax and the maximal power achieved (Ppeak) were recorded. Thirty-eight oarsmen achieved a VO2 plateau and were designated as Pla; 56 did not and were designed as N-Pla. The Pla and N-Pla VO2max, Pamax and maximal HR values were similar. In comparison with N-Pla, the Pla group displayed a rightward shift of the [La]b versus power curve, accounted for by both the increased percentage of VO2max corresponding to 4 mmol l(-1) and the decreased value of [La]b corresponding to Pamax (P<0.05). Pla oarsmen attained a higher Ppeak expressed as % of Pamax (P<0.05) and also showed better ergometer performance (P<0.05). In a sub-group of 53 oarsmen constituted on the basis of Pamax values close to 400 W, for a given power output, the Pla subjects had significantly lower HR, RER, and [La]b values at each sub-maximal stage of the test. These results suggest that achieving a [Formula: see text] plateau during completion of an incremental step protocol accounts for greater muscle ability to maintain homeostasis during exercise. These differences give the oarsmen an advantage in rowing competitions.

  5. Large-Scale Multiantenna Multisine Wireless Power Transfer

    NASA Astrophysics Data System (ADS)

    Huang, Yang; Clerckx, Bruno

    2017-11-01

    Wireless Power Transfer (WPT) is expected to be a technology reshaping the landscape of low-power applications such as the Internet of Things, Radio Frequency identification (RFID) networks, etc. Although there has been some progress towards multi-antenna multi-sine WPT design, the large-scale design of WPT, reminiscent of massive MIMO in communications, remains an open challenge. In this paper, we derive efficient multiuser algorithms based on a generalizable optimization framework, in order to design transmit sinewaves that maximize the weighted-sum/minimum rectenna output DC voltage. The study highlights the significant effect of the nonlinearity introduced by the rectification process on the design of waveforms in multiuser systems. Interestingly, in the single-user case, the optimal spatial domain beamforming, obtained prior to the frequency domain power allocation optimization, turns out to be Maximum Ratio Transmission (MRT). In contrast, in the general weighted sum criterion maximization problem, the spatial domain beamforming optimization and the frequency domain power allocation optimization are coupled. Assuming channel hardening, low-complexity algorithms are proposed based on asymptotic analysis, to maximize the two criteria. The structure of the asymptotically optimal spatial domain precoder can be found prior to the optimization. The performance of the proposed algorithms is evaluated. Numerical results confirm the inefficiency of the linear model-based design for the single and multi-user scenarios. It is also shown that as nonlinear model-based designs, the proposed algorithms can benefit from an increasing number of sinewaves.

  6. A methodology for optimization of wind farm allocation under land restrictions: the case of the Canary Islands

    NASA Astrophysics Data System (ADS)

    Castaño Moraga, C. A.; Suárez Santana, E.; Sabbagh Rodríguez, I.; Nebot Medina, R.; Suárez García, S.; Rodríguez Alvarado, J.; Piernavieja Izquierdo, G.; Ruiz Alzola, J.

    2010-09-01

    Wind farms authorization and power allocations to private investors promoting wind energy projects requires some planification strategies. This issue is even more important under land restrictions, as it is the case of Canary Islands, where numerous specially protected areas are present for environmental reasons and land is a scarce resource. Aware of this limitation, the Regional Government of Canary Islands designed the requirements of a public tender to grant licences to install new wind farms trying to maximize the energy produced in terms of occupied land. In this paper, we detail the methodology developed by the Canary Islands Institute of Technology (ITC, S.A.) to support the work of the technical staff of the Regional Ministry of Industry, responsible for the evaluation of a competitive tender process for awarding power lincenses to private investors. The maximization of wind energy production per unit of area requires an exhaustive wind profile characterization. To that end, wind speed was statistically characterized by means of a Weibull probability density function, which mainly depends on two parameters: the shape parameter K, which determines the slope of the curve, and the average wind speed v , which is a scale parameter. These two parameters have been evaluated at three different heights (40,60,80 m) over the whole canarian archipelago, as well as the main wind speed direction. These parameters are available from the public data source Wind Energy Map of the Canary Islands [1]. The proposed methodology is based on the calculation of an initially defined Energy Efficiency Basic Index (EEBI), which is a performance criteria that weighs the annual energy production of a wind farm per unit of area. The calculation of this parameter considers wind conditions, windturbine characteristics, geometry of windturbine distribution in the wind farm (position within the row and column of machines), and involves four steps: Estimation of the energy produced by every windturbine as if it were isolated from all the other machines of the wind farm, using its power curve and the statistical characterization of the wind profile at the site. Estimation of energy losses due to affections caused by other windturbine in the same row and missalignment with respect to the main wind speed direction. Estimation of energy losses due to affections induced by windturbines located upstream. EEBI calculation as the ratio between the annual energy production and the area occupied by the wind farm, as a function of wind speed profile and wind turbine characteristics. Computations involved above are modeled under a System Theory characterization

  7. Efficient data communication protocols for wireless networks

    NASA Astrophysics Data System (ADS)

    Zeydan, Engin

    In this dissertation, efficient decentralized algorithms are investigated for cost minimization problems in wireless networks. For wireless sensor networks, we investigate both the reduction in the energy consumption and throughput maximization problems separately using multi-hop data aggregation for correlated data in wireless sensor networks. The proposed algorithms exploit data redundancy using a game theoretic framework. For energy minimization, routes are chosen to minimize the total energy expended by the network using best response dynamics to local data. The cost function used in routing takes into account distance, interference and in-network data aggregation. The proposed energy-efficient correlation-aware routing algorithm significantly reduces the energy consumption in the network and converges in a finite number of steps iteratively. For throughput maximization, we consider both the interference distribution across the network and correlation between forwarded data when establishing routes. Nodes along each route are chosen to minimize the interference impact in their neighborhood and to maximize the in-network data aggregation. The resulting network topology maximizes the global network throughput and the algorithm is guaranteed to converge with a finite number of steps using best response dynamics. For multiple antenna wireless ad-hoc networks, we present distributed cooperative and regret-matching based learning schemes for joint transmit beanformer and power level selection problem for nodes operating in multi-user interference environment. Total network transmit power is minimized while ensuring a constant received signal-to-interference and noise ratio at each receiver. In cooperative and regret-matching based power minimization algorithms, transmit beanformers are selected from a predefined codebook to minimize the total power. By selecting transmit beamformers judiciously and performing power adaptation, the cooperative algorithm is shown to converge to pure strategy Nash equilibrium with high probability throughout the iterations in the interference impaired network. On the other hand, the regret-matching learning algorithm is noncooperative and requires minimum amount of overhead. The proposed cooperative and regret-matching based distributed algorithms are also compared with centralized solutions through simulation results.

  8. Are gender differences in upper-body power generated by elite cross-country skiers augmented by increasing the intensity of exercise?

    PubMed

    Hegge, Ann Magdalen; Myhre, Kenneth; Welde, Boye; Holmberg, Hans-Christer; Sandbakk, Øyvind

    2015-01-01

    In the current study, we evaluated the impact of exercise intensity on gender differences in upper-body poling among cross-country skiers, as well as the associated differences in aerobic capacity, maximal strength, body composition, technique and extent of training. Eight male and eight female elite skiers, gender-matched for level of performance by FIS points, carried out a 4-min submaximal, and a 3-min and 30-sec maximal all-out test of isolated upper-body double poling on a Concept2 ski ergometer. Maximal upper-body power and strength (1RM) were determined with a pull-down exercise. In addition, body composition was assessed with a DXA scan and training during the previous six months quantified from diaries. Relative to the corresponding female values (defined as 100%), the power output produced by the men was 88%, 95% and 108% higher during the submaximal, 3-min and 30-sec tests, respectively, and peak power in the pull-down strength exercise was 118% higher (all P<0.001). During the ergometer tests the work performed per cycle by the men was 97%, 102% and 91% greater, respectively, and the men elevated their cycle rate to a greater extent at higher intensities (both P<0.01). Furthermore, men had a 61% higher VO2peak, 58% higher 1RM, relatively larger upper-body mass (61% vs 56%) and reported considerably more upper-body strength and endurance training (all P<0.05). In conclusion, gender differences in upper-body power among cross-country skiers augmented as the intensity of exercise increased. The gender differences observed here are greater than those reported previously for both lower- and whole-body sports and coincided with greater peak aerobic capacity and maximal upper-body strength, relatively more muscle mass in the upper-body, and more extensive training of upper-body strength and endurance among the male skiers.

  9. Optimal Battery Utilization Over Lifetime for Parallel Hybrid Electric Vehicle to Maximize Fuel Economy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patil, Chinmaya; Naghshtabrizi, Payam; Verma, Rajeev

    This paper presents a control strategy to maximize fuel economy of a parallel hybrid electric vehicle over a target life of the battery. Many approaches to maximizing fuel economy of parallel hybrid electric vehicle do not consider the effect of control strategy on the life of the battery. This leads to an oversized and underutilized battery. There is a trade-off between how aggressively to use and 'consume' the battery versus to use the engine and consume fuel. The proposed approach addresses this trade-off by exploiting the differences in the fast dynamics of vehicle power management and slow dynamics of batterymore » aging. The control strategy is separated into two parts, (1) Predictive Battery Management (PBM), and (2) Predictive Power Management (PPM). PBM is the higher level control with slow update rate, e.g. once per month, responsible for generating optimal set points for PPM. The considered set points in this paper are the battery power limits and State Of Charge (SOC). The problem of finding the optimal set points over the target battery life that minimize engine fuel consumption is solved using dynamic programming. PPM is the lower level control with high update rate, e.g. a second, responsible for generating the optimal HEV energy management controls and is implemented using model predictive control approach. The PPM objective is to find the engine and battery power commands to achieve the best fuel economy given the battery power and SOC constraints imposed by PBM. Simulation results with a medium duty commercial hybrid electric vehicle and the proposed two-level hierarchical control strategy show that the HEV fuel economy is maximized while meeting a specified target battery life. On the other hand, the optimal unconstrained control strategy achieves marginally higher fuel economy, but fails to meet the target battery life.« less

  10. Are Gender Differences in Upper-Body Power Generated by Elite Cross-Country Skiers Augmented by Increasing the Intensity of Exercise?

    PubMed Central

    Hegge, Ann Magdalen; Myhre, Kenneth; Welde, Boye; Holmberg, Hans-Christer; Sandbakk, Øyvind

    2015-01-01

    In the current study, we evaluated the impact of exercise intensity on gender differences in upper-body poling among cross-country skiers, as well as the associated differences in aerobic capacity, maximal strength, body composition, technique and extent of training. Eight male and eight female elite skiers, gender-matched for level of performance by FIS points, carried out a 4-min submaximal, and a 3-min and 30-sec maximal all-out test of isolated upper-body double poling on a Concept2 ski ergometer. Maximal upper-body power and strength (1RM) were determined with a pull-down exercise. In addition, body composition was assessed with a DXA scan and training during the previous six months quantified from diaries. Relative to the corresponding female values (defined as 100%), the power output produced by the men was 88%, 95% and 108% higher during the submaximal, 3-min and 30-sec tests, respectively, and peak power in the pull-down strength exercise was 118% higher (all P<0.001). During the ergometer tests the work performed per cycle by the men was 97%, 102% and 91% greater, respectively, and the men elevated their cycle rate to a greater extent at higher intensities (both P<0.01). Furthermore, men had a 61% higher VO2peak, 58% higher 1RM, relatively larger upper-body mass (61% vs 56%) and reported considerably more upper-body strength and endurance training (all P<0.05). In conclusion, gender differences in upper-body power among cross-country skiers augmented as the intensity of exercise increased. The gender differences observed here are greater than those reported previously for both lower- and whole-body sports and coincided with greater peak aerobic capacity and maximal upper-body strength, relatively more muscle mass in the upper-body, and more extensive training of upper-body strength and endurance among the male skiers. PMID:26000713

  11. Expected p-values in light of an ROC curve analysis applied to optimal multiple testing procedures.

    PubMed

    Vexler, Albert; Yu, Jihnhee; Zhao, Yang; Hutson, Alan D; Gurevich, Gregory

    2017-01-01

    Many statistical studies report p-values for inferential purposes. In several scenarios, the stochastic aspect of p-values is neglected, which may contribute to drawing wrong conclusions in real data experiments. The stochastic nature of p-values makes their use to examine the performance of given testing procedures or associations between investigated factors to be difficult. We turn our focus on the modern statistical literature to address the expected p-value (EPV) as a measure of the performance of decision-making rules. During the course of our study, we prove that the EPV can be considered in the context of receiver operating characteristic (ROC) curve analysis, a well-established biostatistical methodology. The ROC-based framework provides a new and efficient methodology for investigating and constructing statistical decision-making procedures, including: (1) evaluation and visualization of properties of the testing mechanisms, considering, e.g. partial EPVs; (2) developing optimal tests via the minimization of EPVs; (3) creation of novel methods for optimally combining multiple test statistics. We demonstrate that the proposed EPV-based approach allows us to maximize the integrated power of testing algorithms with respect to various significance levels. In an application, we use the proposed method to construct the optimal test and analyze a myocardial infarction disease dataset. We outline the usefulness of the "EPV/ROC" technique for evaluating different decision-making procedures, their constructions and properties with an eye towards practical applications.

  12. Optimal Design of Wireless Power Transmission Links for Millimeter-Sized Biomedical Implants.

    PubMed

    Ahn, Dukju; Ghovanloo, Maysam

    2016-02-01

    This paper presents a design methodology for RF power transmission to millimeter-sized implantable biomedical devices. The optimal operating frequency and coil geometries are found such that power transfer efficiency (PTE) and tissue-loss-constrained allowed power are maximized. We define receiver power reception susceptibility (Rx-PRS) and transmitter figure of merit (Tx-FoM) such that their multiplication yields the PTE. Rx-PRS and Tx-FoM define the roles of the Rx and Tx in the PTE, respectively. First, the optimal Rx coil geometry and operating frequency range are identified such that the Rx-PRS is maximized for given implant constraints. Since the Rx is very small and has lesser design freedom than the Tx, the overall operating frequency is restricted mainly by the Rx. Rx-PRS identifies such operating frequency constraint imposed by the Rx. Secondly, the Tx coil geometry is selected such that the Tx-FoM is maximized under the frequency constraint at which the Rx-PRS was saturated. This aligns the target frequency range of Tx optimization with the frequency range at which Rx performance is high, resulting in the maximum PTE. Finally, we have found that even in the frequency range at which the PTE is relatively flat, the tissue loss per unit delivered power can be significantly different for each frequency. The Rx-PRS can predict the frequency range at which the tissue loss per unit delivered power is minimized while PTE is maintained high. In this way, frequency adjustment for the PTE and tissue-loss-constrained allowed power is realized by characterizing the Rx-PRS. The design procedure was verified through full-wave electromagnetic field simulations and measurements using de-embedding method. A prototype implant, 1 mm in diameter, achieved PTE of 0.56% ( -22.5 dB) and power delivered to load (PDL) was 224 μW at 200 MHz with 12 mm Tx-to-Rx separation in the tissue environment.

  13. Crossover and maximal fat-oxidation points in sedentary healthy subjects: methodological issues.

    PubMed

    Gmada, N; Marzouki, H; Haboubi, M; Tabka, Z; Shephard, R J; Bouhlel, E

    2012-02-01

    Our study aimed to assess the influence of protocol on the crossover point and maximal fat-oxidation (LIPOX(max)) values in sedentary, but otherwise healthy, young men. Maximal oxygen intake was assessed in 23 subjects, using a progressive maximal cycle ergometer test. Twelve sedentary males (aged 20.5±1.0 years) whose directly measured maximal aerobic power (MAP) values were lower than their theoretical maximal values (tMAP) were selected from this group. These individuals performed, in random sequence, three submaximal graded exercise tests, separated by three-day intervals; work rates were based on the tMAP in one test and on MAP in the remaining two. The third test was used to assess the reliability of data. Heart rate, respiratory parameters, blood lactate, the crossover point and LIPOX(max) values were measured during each of these tests. The crossover point and LIPOX(max) values were significantly lower when the testing protocol was based on tMAP rather than on MAP (P<0.001). Respiratory exchange ratios were significantly lower with MAP than with tMAP at 30, 40, 50 and 60% of maximal aerobic power (P<0.01). At the crossover point, lactate and 5-min postexercise oxygen consumption (EPOC(5 min)) values were significantly higher using tMAP rather than MAP (P<0.001). During the first 5 min of recovery, EPOC(5 min) and blood lactate were significantly correlated (r=0.89; P<0.001). Our data show that, to assess the crossover point and LIPOX(max) values for research purposes, the protocol must be based on the measured MAP rather than on a theoretical value. Such a determination should improve individualization of training for initially sedentary subjects. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  14. Prediction equations for maximal respiratory pressures of Brazilian adolescents.

    PubMed

    Mendes, Raquel E F; Campos, Tania F; Macêdo, Thalita M F; Borja, Raíssa O; Parreira, Verônica F; Mendonça, Karla M P P

    2013-01-01

    The literature emphasizes the need for studies to provide reference values and equations able to predict respiratory muscle strength of Brazilian subjects at different ages and from different regions of Brazil. To develop prediction equations for maximal respiratory pressures (MRP) of Brazilian adolescents. In total, 182 healthy adolescents (98 boys and 84 girls) aged between 12 and 18 years, enrolled in public and private schools in the city of Natal-RN, were evaluated using an MVD300 digital manometer (Globalmed®) according to a standardized protocol. Statistical analysis was performed using SPSS Statistics 17.0 software, with a significance level of 5%. Data normality was verified using the Kolmogorov-Smirnov test, and descriptive analysis results were expressed as the mean and standard deviation. To verify the correlation between the MRP and the independent variables (age, weight, height and sex), the Pearson correlation test was used. To obtain the prediction equations, stepwise multiple linear regression was used. The variables height, weight and sex were correlated to MRP. However, weight and sex explained part of the variability of MRP, and the regression analysis in this study indicated that these variables contributed significantly in predicting maximal inspiratory pressure, and only sex contributed significantly to maximal expiratory pressure. This study provides reference values and two models of prediction equations for maximal inspiratory and expiratory pressures and sets the necessary normal lower limits for the assessment of the respiratory muscle strength of Brazilian adolescents.

  15. Determining the Optimum Power Load in Jump Squat Using the Mean Propulsive Velocity

    PubMed Central

    Loturco, Irineu; Nakamura, Fabio Yuzo; Tricoli, Valmor; Kobal, Ronaldo; Cal Abad, Cesar Cavinato; Kitamura, Katia; Ugrinowitsch, Carlos; Gil, Saulo; Pereira, Lucas Adriano; González-Badillo, Juan José

    2015-01-01

    The jump squat is one of the exercises most frequently used to improve lower body power production, which influences sports performance. However, the traditional determination of the specific workload at which power production is maximized (i.e., optimum power load) is time-consuming and requires one-repetition maximum tests. Therefore, the aim of this study was to verify whether elite athletes from different sports would produce maximum mean propulsive power values at a narrow range of mean propulsive velocities, resulting in similar jump heights. One hundred and nine elite athletes from several individual/team sport disciplines underwent repetitions at maximal velocity with progressive loads, starting at 40% of their body mass with increments of 10% to determine the individual optimum power zone. Results indicated that regardless of sport discipline, the athletes’ optimum mean propulsive power was achieved at a mean propulsive velocity close to 1.0 m.s−1 (1.01 ± 0.07 m.s−1) and at a jump height close to 20 cm (20.47 ± 1.42 cm). Data were narrowly scattered around these values. Therefore, jump squat optimum power load can be determined simply by means of mean propulsive velocity or jump height determination in training/testing settings, allowing it to be implemented quickly in strength/power training. PMID:26444293

  16. Chronic low back pain in patients with systemic lupus erythematosus: prevalence and predictors of back muscle strength and its correlation with disability.

    PubMed

    Cezarino, Raíssa Sudré; Cardoso, Jefferson Rosa; Rodrigues, Kedma Neves; Magalhães, Yasmin Santana; Souza, Talita Yokoy de; Mota, Lícia Maria Henrique da; Bonini-Rocha, Ana Clara; McVeigh, Joseph; Martins, Wagner Rodrigues

    To determine the prevalence of Chronic Low Back Pain and predictors of Back Muscle Strength in patients with Systemic Lupus Erythematosus. Cross-sectional study. Ninety-six ambulatory patients with lupus were selected by non-probability sampling and interviewed and tested during medical consultation. The outcomes measurements were: Point prevalence of chronic low back pain, Oswestry Disability Index, Tampa Scale of Kinesiophobia, Fatigue Severity Scale and maximal voluntary isometric contractions of handgrip and of the back muscles. Correlation coefficient and multiple linear regression were used in statistical analysis. Of the 96 individuals interviewed, 25 had chronic low back pain, indicating a point prevalence of 26% (92% women). The correlation between the Oswestry Index and maximal voluntary isometric contraction of the back muscles was r=-0.4, 95% CI [-0.68; -0.01] and between the maximal voluntary isometric contraction of handgrip and of the back muscles was r=0.72, 95% CI [0.51; 0.88]. The regression model presented the highest value of R 2 being observed when maximal voluntary isometric contraction of the back muscles was tested with five independent variables (63%). In this model handgrip strength was the only predictive variable (β=0.61, p=0.001). The prevalence of chronic low back pain in individuals with systemic lupus erythematosus was 26%. The maximal voluntary isometric contraction of the back muscles was 63% predicted by five variables of interest, however, only the handgrip strength was a statistically significant predictive variable. The maximal voluntary isometric contraction of the back muscles presented a linear relation directly proportional to handgrip and inversely proportional to Oswestry Index i.e. stronger back muscles are associated with lower disability scores. Copyright © 2017. Published by Elsevier Editora Ltda.

  17. Reply to "Comment on `Third law of thermodynamics as a key test of generalized entropies' "

    NASA Astrophysics Data System (ADS)

    Bento, E. P.; Viswanathan, G. M.; da Luz, M. G. E.; Silva, R.

    2015-07-01

    In Bento et al. [Phys. Rev. E 91, 039901 (2015), 10.1103/PhysRevE.91.039901] we develop a method to verify if an arbitrary generalized statistics does or does not obey the third law of thermodynamics. As examples, we address two important formulations, Kaniadakis and Tsallis. In their Comment on the paper, Bagci and Oikonomou suggest that our examination of the Tsallis statistics is valid only for q ≥1 , using arguments like there is no distribution maximizing the Tsallis entropy for the interval q <0 (in which the third law is not verified) compatible with the problem energy expression. In this Reply, we first (and most importantly) show that the Comment misses the point. In our original work we have considered the now already standard construction of the Tsallis statistics. So, if indeed such statistics lacks a maximization principle (a fact irrelevant in our protocol), this is an inherent feature of the statistics itself and not a problem with our analysis. Second, some arguments used by Bagci and Oikonomou (for 0

  18. Maximizing photovoltaic power generation of a space-dart configured satellite

    NASA Astrophysics Data System (ADS)

    Lee, Dae Young; Cutler, James W.; Mancewicz, Joe; Ridley, Aaron J.

    2015-06-01

    Many small satellites are power constrained due to their minimal solar panel area and the eclipse environment of low-Earth orbit. As with larger satellites, these small satellites, including CubeSats, use deployable power arrays to increase power production. This presents a design opportunity to develop various objective functions related to energy management and methods for optimizing these functions over a satellite design. A novel power generation model was created, and a simulation system was developed to evaluate various objective functions describing energy management for complex satellite designs. The model uses a spacecraft-body-fixed spherical coordinate system to analyze the complex geometry of a satellite's self-induced shadowing with computation provided by the Open Graphics Library. As an example design problem, a CubeSat configured as a space-dart with four deployable panels is optimized. Due to the fast computation speed of the solution, an exhaustive search over the design space is used to find the solar panel deployment angles which maximize total power generation. Simulation results are presented for a variety of orbit scenarios. The method is extendable to a variety of complex satellite geometries and power generation systems.

  19. Adjacency Matrix-Based Transmit Power Allocation Strategies in Wireless Sensor Networks

    PubMed Central

    Consolini, Luca; Medagliani, Paolo; Ferrari, Gianluigi

    2009-01-01

    In this paper, we present an innovative transmit power control scheme, based on optimization theory, for wireless sensor networks (WSNs) which use carrier sense multiple access (CSMA) with collision avoidance (CA) as medium access control (MAC) protocol. In particular, we focus on schemes where several remote nodes send data directly to a common access point (AP). Under the assumption of finite overall network transmit power and low traffic load, we derive the optimal transmit power allocation strategy that minimizes the packet error rate (PER) at the AP. This approach is based on modeling the CSMA/CA MAC protocol through a finite state machine and takes into account the network adjacency matrix, depending on the transmit power distribution and determining the network connectivity. It will be then shown that the transmit power allocation problem reduces to a convex constrained minimization problem. Our results show that, under the assumption of low traffic load, the power allocation strategy, which guarantees minimal delay, requires the maximization of network connectivity, which can be equivalently interpreted as the maximization of the number of non-zero entries of the adjacency matrix. The obtained theoretical results are confirmed by simulations for unslotted Zigbee WSNs. PMID:22346705

  20. Multi-mode evaluation of power-maximizing cross-flow turbine controllers

    DOE PAGES

    Forbush, Dominic; Cavagnaro, Robert J.; Donegan, James; ...

    2017-09-21

    A general method for predicting and evaluating the performance of three candidate cross-flow turbine power-maximizing controllers is presented in this paper using low-order dynamic simulation, scaled laboratory experiments, and full-scale field testing. For each testing mode and candidate controller, performance metrics quantifying energy capture (ability of a controller to maximize power), variation in torque and rotation rate (related to drive train fatigue), and variation in thrust loads (related to structural fatigue) are quantified for two purposes. First, for metrics that could be evaluated across all testing modes, we considered the accuracy with which simulation or laboratory experiments could predict performancemore » at full scale. Second, we explored the utility of these metrics to contrast candidate controller performance. For these turbines and set of candidate controllers, energy capture was found to only differentiate controller performance in simulation, while the other explored metrics were able to predict performance of the full-scale turbine in the field with various degrees of success. Finally, effects of scale between laboratory and full-scale testing are considered, along with recommendations for future improvements to dynamic simulations and controller evaluation.« less

  1. Novel Aerodynamic Design for Formula SAE Vehicles

    NASA Astrophysics Data System (ADS)

    Sentongo, Samuel; Carter, Austin; Cecil, Christopher; Feier, Ioan

    2017-11-01

    This paper identifies and evaluates the design characteristics of a novel airfoil that harnesses the Magnus Effect, applying a moving-surface boundary-layer control (MSBC) method to a Formula SAE Vehicle. The MSBC minimizes adverse pressure gradient and delays boundary layer separation through the use of a conveyor belt that interacts with the airfoil boundary layer. The MSBC allows dynamic control of the aerodynamic coefficients by variation of the belt speed, minimizing drag in high speed straights and maximizing downforce during vehicle cornering. A conveyer belt wing measuring approximately 0.9 x 0.9m in planform was designed and built to test the mechanical setup for such a MSBC wing. This study follows the relationship between inputted power and outputted surface velocity, with the goal being to maximize speed output vs. power input. The greatest hindrance to maximizing speed output is friction among belts, rollers, and stationary members. The maximum belt speed achieved during testing was 5.9 m/s with a power input of 48.8 W, which corresponds to 45.8 N of downforce based on 2D CFD results. Ongoing progress on this project is presented. United States Air Force Academy.

  2. Effects of combined high intensity arm and leg training on performance and cardio-respiratory measures.

    PubMed

    Zinner, Christoph; Sperlich, Billy; Born, Dennis-Peter; Michels, Guido

    2017-01-01

    The purpose of this study was to investigate the effects of combined arm and leg high-intensity low-volume interval training (HIITarm+leg) on maximal oxygen uptake, myocardial measures (i.e. stroke volume, cardiac output, ejection fraction), Tissue Oxygenation Index (TOI) of the vastus lateralis and triceps brachii, as well as power output in comparison to leg HIIT (HIITleg) only. The 20 healthy, male and female volunteers completed six sessions of either HIITleg on a cycle ergometer or HIITarm+leg on an arm and leg cycle ergometer. During pre- and post-testing, the volunteers completed a submaximal and incremental test to exhaustion on a cycle ergometer. Magnitude based interference revealed likely to very likely beneficial effects for HIITarm+leg compared to HIITleg in maximal oxygen uptake, cardiac measures as well peak power output. The TOI following HIITarm+leg demonstrated likely to very likely increased oxygenation in the triceps brachii or the vastus lateralis when compared to HIITleg. The results suggest that six sessions of HIITarm+leg may likely to very likely improve maximal oxygen uptake, some inotropy-related cardiac measures with improved tissue oxygenation of the triceps brachii and vastus lateralis muscles resulting in greater leg peak power output.

  3. Multi-mode evaluation of power-maximizing cross-flow turbine controllers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Forbush, Dominic; Cavagnaro, Robert J.; Donegan, James

    A general method for predicting and evaluating the performance of three candidate cross-flow turbine power-maximizing controllers is presented in this paper using low-order dynamic simulation, scaled laboratory experiments, and full-scale field testing. For each testing mode and candidate controller, performance metrics quantifying energy capture (ability of a controller to maximize power), variation in torque and rotation rate (related to drive train fatigue), and variation in thrust loads (related to structural fatigue) are quantified for two purposes. First, for metrics that could be evaluated across all testing modes, we considered the accuracy with which simulation or laboratory experiments could predict performancemore » at full scale. Second, we explored the utility of these metrics to contrast candidate controller performance. For these turbines and set of candidate controllers, energy capture was found to only differentiate controller performance in simulation, while the other explored metrics were able to predict performance of the full-scale turbine in the field with various degrees of success. Finally, effects of scale between laboratory and full-scale testing are considered, along with recommendations for future improvements to dynamic simulations and controller evaluation.« less

  4. Effect of fluid ingestion on neuromuscular function during prolonged cycling exercise.

    PubMed

    Vallier, J-M; Grego, F; Basset, F; Lepers, R; Bernard, T; Brisswalter, J

    2005-04-01

    To investigate the effects of fluid ingestion on neuromuscular function during prolonged cycling exercise. Eight well trained subjects exercised for 180 minutes in a moderate environment at a workload requiring approximately 60% maximal oxygen uptake. Two conditions, fluid (F) and no fluid (NF) ingestion, were investigated. During maximal voluntary isometric contraction (MVC), prolonged cycling exercise reduced (p<0.05) the maximal force generating capacity of quadriceps muscles (after three hours of cycling) and root mean square (RMS) values (after two hours of cycling) with no difference between the two conditions despite greater body weight loss (p<0.05) in NF. The mean power frequency (MPF) for vastus lateralis muscle was reduced (p<0.05) and the rate of force development (RFD) was increased (p<0.05) only during NF. During cycling exercise, integrated electromyographic activity and perceived exertion were increased in both conditions (p<0.05) with no significant effect of fluid ingestion. The results suggest that fluid ingestion did not prevent the previously reported decrease in maximal force with exercise duration, but seems to have a positive effect on some indicators of neuromuscular fatigue such as mean power frequency and rate of force development during maximal voluntary contraction. Further investigations are needed to assess the effect of change in hydration on neural mechanisms linked to the development of muscular fatigue during prolonged exercise.

  5. Employer Learning and the Signaling Value of Education. National Longitudinal Surveys Discussion Paper.

    ERIC Educational Resources Information Center

    Altonji, Joseph G.; Pierret, Charles R.

    A statistical analysis was performed to test the hypothesis that, if profit-maximizing firms have limited information about the general productivity of new workers, they may choose to use easily observable characteristics such as years of education to discriminate statistically among workers. Information about employer learning was obtained by…

  6. Teaching Statistics from the Operating Table: Minimally Invasive and Maximally Educational

    ERIC Educational Resources Information Center

    Nowacki, Amy S.

    2015-01-01

    Statistics courses that focus on data analysis in isolation, discounting the scientific inquiry process, may not motivate students to learn the subject. By involving students in other steps of the inquiry process, such as generating hypotheses and data, students may become more interested and vested in the analysis step. Additionally, such an…

  7. Statistical power in parallel group point exposure studies with time-to-event outcomes: an empirical comparison of the performance of randomized controlled trials and the inverse probability of treatment weighting (IPTW) approach.

    PubMed

    Austin, Peter C; Schuster, Tibor; Platt, Robert W

    2015-10-15

    Estimating statistical power is an important component of the design of both randomized controlled trials (RCTs) and observational studies. Methods for estimating statistical power in RCTs have been well described and can be implemented simply. In observational studies, statistical methods must be used to remove the effects of confounding that can occur due to non-random treatment assignment. Inverse probability of treatment weighting (IPTW) using the propensity score is an attractive method for estimating the effects of treatment using observational data. However, sample size and power calculations have not been adequately described for these methods. We used an extensive series of Monte Carlo simulations to compare the statistical power of an IPTW analysis of an observational study with time-to-event outcomes with that of an analysis of a similarly-structured RCT. We examined the impact of four factors on the statistical power function: number of observed events, prevalence of treatment, the marginal hazard ratio, and the strength of the treatment-selection process. We found that, on average, an IPTW analysis had lower statistical power compared to an analysis of a similarly-structured RCT. The difference in statistical power increased as the magnitude of the treatment-selection model increased. The statistical power of an IPTW analysis tended to be lower than the statistical power of a similarly-structured RCT.

  8. Integrating Multiple Correlated Phenotypes for Genetic Association Analysis by Maximizing Heritability

    PubMed Central

    Zhou, Jin J.; Cho, Michael H.; Lange, Christoph; Lutz, Sharon; Silverman, Edwin K.; Laird, Nan M.

    2015-01-01

    Many correlated disease variables are analyzed jointly in genetic studies in the hope of increasing power to detect causal genetic variants. One approach involves assessing the relationship between each phenotype and each single nucleotide polymorphism (SNP) individually and using a Bonferroni correction for the effective number of tests conducted. Alternatively, one can apply a multivariate regression or a dimension reduction technique, such as principal component analysis (PCA), and test for the association with the principal components (PC) of the phenotypes rather than the individual phenotypes. Inspired by the previous approaches of combining phenotypes to maximize heritability at individual SNPs, in this paper, we propose to construct a maximally heritable phenotype (MaxH) by taking advantage of the estimated total heritability and co-heritability. The heritability and co-heritability only need to be estimated once, therefore our method is applicable to genome-wide scans. MaxH phenotype is a linear combination of the individual phenotypes with increased heritability and power over the phenotypes being combined. Simulations show that the heritability and power achieved agree well with the theory for large samples and two phenotypes. We compare our approach with commonly used methods and assess both the heritability and the power of the MaxH phenotype. Moreover we provide suggestions for how to choose the phenotypes for combination. An application of our approach to a COPD genome-wide association study shows the practical relevance. PMID:26111731

  9. Neuromuscular response differences to power vs strength back squat exercise in elite athletes.

    PubMed

    Brandon, R; Howatson, G; Strachan, F; Hunter, A M

    2015-10-01

    The study's aim was to establish the neuromuscular responses in elite athletes during and following maximal 'explosive' regular back squat exercise at heavy, moderate, and light loads. Ten elite track and field athletes completed 10 sets of five maximal squat repetitions on three separate days. Knee extension maximal isometric voluntary contraction (MIVC), rate of force development (RFD) and evoked peak twitch force (Pt) assessments were made pre- and post-session. Surface electromyography [root mean square (RMS)] and mechanical measurements were recorded during repetitions. The heavy session resulted in the greatest repetition impulse in comparison to moderate and light sessions (P < 0.001), while the latter showed highest repetition power (P < 0.001). MIVC, RFD, and Pt were significantly reduced post-session (P < 0.01), with greatest reduction observed after the heavy, followed by the moderate and light sessions accordingly. Power significantly reduced during the heavy session only (P < 0.001), and greater increases in RMS occurred during heavy session (P < 0.001), followed by moderate, with no change during light session. In conclusion, this study has shown in elite athletes that the moderate load is optimal for providing a neuromuscular stimulus but with limited fatigue. This type of intervention could be potentially used in the development of both strength and power in elite athletic populations. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Impairment of Performance Variables After In-Season Strength-Training Cessation in Elite Cyclists.

    PubMed

    Rønnestad, Bent R; Hansen, Joar; Hollan, Ivana; Spencer, Matt; Ellefsen, Stian

    2016-09-01

    The current study investigated the effects of 8 wk of strength-training cessation after 25 wk of strength training on strength- and cycling-performance characteristics. Elite cyclists were randomly assigned to either 25 wk of endurance training combined with heavy strength training (EXP, n = 7, maximal oxygen uptake [V̇O 2max ] 77 ± 6 mL . kg -1 . min -1 ; 3 × 4-10 RM, 1 to 2 d/wk) or to endurance training only (CON, n = 7, V̇O 2max 73 ± 5 mL . kg -1 . min -1 ). Thereafter, both groups performed endurance training only for 8 wk, coinciding with the initial part of the competition season. Data were assessed for practical significance using magnitude-based inferences. During the 25-wk preparatory period, EXP had a larger positive impact on maximal isometric half-squat force, squat jump (SJ), maximal aerobic power (W max ), power output at 4 mmol/L [La], and mean power in 30-s Wingate test than did CON (ES = 0.46-0.74). Conversely, during the 8-wk competition period EXP had a reduction in SJ, W max , and mean power in the 30-s Wingate test compared with CON (ES = 0.49-0.84). The present findings suggest rapid decline of adaptations on termination of strength training during the first 8 wk of the competition period in elite cyclists.

  11. Two-loop controller for maximizing performance of a grid-connected photovoltaic - fuel cell hybrid power plant

    NASA Astrophysics Data System (ADS)

    Ro, Kyoungsoo

    The study started with the requirement that a photovoltaic (PV) power source should be integrated with other supplementary power sources whether it operates in a stand-alone or grid-connected mode. First, fuel cells for a backup of varying PV power were compared in detail with batteries and were found to have more operational benefits. Next, maximizing performance of a grid-connected PV-fuel cell hybrid system by use of a two-loop controller was discussed. One loop is a neural network controller for maximum power point tracking, which extracts maximum available solar power from PV arrays under varying conditions of insolation, temperature, and system load. A real/reactive power controller (RRPC) is the other loop. The RRPC meets the system's requirement for real and reactive powers by controlling incoming fuel to fuel cell stacks as well as switching control signals to a power conditioning subsystem. The RRPC is able to achieve more versatile control of real/reactive powers than the conventional power sources since the hybrid power plant does not contain any rotating mass. Results of time-domain simulations prove not only effectiveness of the proposed computer models of the two-loop controller, but also their applicability for use in transient stability analysis of the hybrid power plant. Finally, environmental evaluation of the proposed hybrid plant was made in terms of plant's land requirement and lifetime COsb2 emissions, and then compared with that of the conventional fossil-fuel power generating forms.

  12. Discrete statistical model of fatigue crack growth in a Ni-base superalloy, capable of life prediction

    NASA Astrophysics Data System (ADS)

    Boyd-Lee, Ashley; King, Julia

    1992-07-01

    A discrete statistical model of fatigue crack growth in a nickel base superalloy Waspaloy, which is quantitative from the start of the short crack regime to failure, is presented. Instantaneous crack growth rate distributions and persistence of arrest distributions are used to compute fatigue lives and worst case scenarios without extrapolation. The basis of the model is non-material specific, it provides an improved method of analyzing crack growth rate data. For Waspaloy, the model shows the importance of good bulk fatigue crack growth resistance to resist early short fatigue crack growth and the importance of maximizing crack arrest both by the presence of a proportion of small grains and by maximizing grain boundary corrugation.

  13. Identifying reprioritization response shift in a stroke caregiver population: a comparison of missing data methods.

    PubMed

    Sajobi, Tolulope T; Lix, Lisa M; Singh, Gurbakhshash; Lowerison, Mark; Engbers, Jordan; Mayo, Nancy E

    2015-03-01

    Response shift (RS) is an important phenomenon that influences the assessment of longitudinal changes in health-related quality of life (HRQOL) studies. Given that RS effects are often small, missing data due to attrition or item non-response can contribute to failure to detect RS effects. Since missing data are often encountered in longitudinal HRQOL data, effective strategies to deal with missing data are important to consider. This study aims to compare different imputation methods on the detection of reprioritization RS in the HRQOL of caregivers of stroke survivors. Data were from a Canadian multi-center longitudinal study of caregivers of stroke survivors over a one-year period. The Stroke Impact Scale physical function score at baseline, with a cutoff of 75, was used to measure patient stroke severity for the reprioritization RS analysis. Mean imputation, likelihood-based expectation-maximization imputation, and multiple imputation methods were compared in test procedures based on changes in relative importance weights to detect RS in SF-36 domains over a 6-month period. Monte Carlo simulation methods were used to compare the statistical powers of relative importance test procedures for detecting RS in incomplete longitudinal data under different missing data mechanisms and imputation methods. Of the 409 caregivers, 15.9 and 31.3 % of them had missing data at baseline and 6 months, respectively. There were no statistically significant changes in relative importance weights on any of the domains when complete-case analysis was adopted. But statistical significant changes were detected on physical functioning and/or vitality domains when mean imputation or EM imputation was adopted. There were also statistically significant changes in relative importance weights for physical functioning, mental health, and vitality domains when multiple imputation method was adopted. Our simulations revealed that relative importance test procedures were least powerful under complete-case analysis method and most powerful when a mean imputation or multiple imputation method was adopted for missing data, regardless of the missing data mechanism and proportion of missing data. Test procedures based on relative importance measures are sensitive to the type and amount of missing data and imputation method. Relative importance test procedures based on mean imputation and multiple imputation are recommended for detecting RS in incomplete data.

  14. Finite length filters with maximally confined spectral power

    NASA Technical Reports Server (NTRS)

    Knight, J. W.; Newman, C. E.

    1975-01-01

    The problem of finding a function which, in addition to being zero outside a specified range in x-space, has its spectral power well confined to a certain range in k-space is solved numerically. Properties of the solutions are also discussed.

  15. Nondissipative optimum charge regulator

    NASA Technical Reports Server (NTRS)

    Rosen, R.; Vitebsky, J. N.

    1970-01-01

    Optimum charge regulator provides constant level charge/discharge control of storage batteries. Basic power transfer and control is performed by solar panel coupled to battery through power switching circuit. Optimum controller senses battery current and modifies duty cycle of switching circuit to maximize current available to battery.

  16. High Thrust-to-Power Annular Engine Technology

    NASA Technical Reports Server (NTRS)

    Patterson, Michael J.; Thomas, Robert E.; Crofton, Mark W.; Young, Jason A.; Foster, John E.

    2015-01-01

    Gridded ion engines have the highest efficiency and total impulse of any mature electric propulsion technology, and have been successfully implemented for primary propulsion in both geocentric and heliocentric environments with excellent ground/in-space correlation of performance. However, they have not been optimized to maximize thrust-to-power, an important parameter for Earth orbit transfer applications. This publication discusses technology development work intended to maximize this parameter. These activities include investigating the capabilities of a non-conventional design approach, the annular engine, which has the potential of exceeding the thrust-to-power of other EP technologies. This publication discusses the status of this work, including the fabrication and initial tests of a large-area annular engine. This work is being conducted in collaboration among NASA Glenn Research Center, The Aerospace Corporation, and the University of Michigan.

  17. High Thrust-to-Power Annular Engine Technology

    NASA Technical Reports Server (NTRS)

    Patterson, Michael; Thomas, Robert; Crofton, Mark; Young, Jason A.; Foster, John E.

    2015-01-01

    Gridded ion engines have the highest efficiency and total impulse of any mature electric propulsion technology, and have been successfully implemented for primary propulsion in both geocentric and heliocentric environments with excellent ground-in-space correlation of performance. However, they have not been optimized to maximize thrust-to-power, an important parameter for Earth orbit transfer applications. This publication discusses technology development work intended to maximize this parameter. These activities include investigating the capabilities of a non-conventional design approach, the annular engine, which has the potential of exceeding the thrust-to-power of other EP technologies. This publication discusses the status of this work, including the fabrication and initial tests of a large-area annular engine. This work is being conducted in collaboration among NASA Glenn Research Center, The Aerospace Corporation, and the University of Michigan.

  18. Statistical Power in Meta-Analysis

    ERIC Educational Resources Information Center

    Liu, Jin

    2015-01-01

    Statistical power is important in a meta-analysis study, although few studies have examined the performance of simulated power in meta-analysis. The purpose of this study is to inform researchers about statistical power estimation on two sample mean difference test under different situations: (1) the discrepancy between the analytical power and…

  19. Analyzing Large Gene Expression and Methylation Data Profiles Using StatBicRM: Statistical Biclustering-Based Rule Mining

    PubMed Central

    Maulik, Ujjwal; Mallik, Saurav; Mukhopadhyay, Anirban; Bandyopadhyay, Sanghamitra

    2015-01-01

    Microarray and beadchip are two most efficient techniques for measuring gene expression and methylation data in bioinformatics. Biclustering deals with the simultaneous clustering of genes and samples. In this article, we propose a computational rule mining framework, StatBicRM (i.e., statistical biclustering-based rule mining) to identify special type of rules and potential biomarkers using integrated approaches of statistical and binary inclusion-maximal biclustering techniques from the biological datasets. At first, a novel statistical strategy has been utilized to eliminate the insignificant/low-significant/redundant genes in such way that significance level must satisfy the data distribution property (viz., either normal distribution or non-normal distribution). The data is then discretized and post-discretized, consecutively. Thereafter, the biclustering technique is applied to identify maximal frequent closed homogeneous itemsets. Corresponding special type of rules are then extracted from the selected itemsets. Our proposed rule mining method performs better than the other rule mining algorithms as it generates maximal frequent closed homogeneous itemsets instead of frequent itemsets. Thus, it saves elapsed time, and can work on big dataset. Pathway and Gene Ontology analyses are conducted on the genes of the evolved rules using David database. Frequency analysis of the genes appearing in the evolved rules is performed to determine potential biomarkers. Furthermore, we also classify the data to know how much the evolved rules are able to describe accurately the remaining test (unknown) data. Subsequently, we also compare the average classification accuracy, and other related factors with other rule-based classifiers. Statistical significance tests are also performed for verifying the statistical relevance of the comparative results. Here, each of the other rule mining methods or rule-based classifiers is also starting with the same post-discretized data-matrix. Finally, we have also included the integrated analysis of gene expression and methylation for determining epigenetic effect (viz., effect of methylation) on gene expression level. PMID:25830807

  20. Analyzing large gene expression and methylation data profiles using StatBicRM: statistical biclustering-based rule mining.

    PubMed

    Maulik, Ujjwal; Mallik, Saurav; Mukhopadhyay, Anirban; Bandyopadhyay, Sanghamitra

    2015-01-01

    Microarray and beadchip are two most efficient techniques for measuring gene expression and methylation data in bioinformatics. Biclustering deals with the simultaneous clustering of genes and samples. In this article, we propose a computational rule mining framework, StatBicRM (i.e., statistical biclustering-based rule mining) to identify special type of rules and potential biomarkers using integrated approaches of statistical and binary inclusion-maximal biclustering techniques from the biological datasets. At first, a novel statistical strategy has been utilized to eliminate the insignificant/low-significant/redundant genes in such way that significance level must satisfy the data distribution property (viz., either normal distribution or non-normal distribution). The data is then discretized and post-discretized, consecutively. Thereafter, the biclustering technique is applied to identify maximal frequent closed homogeneous itemsets. Corresponding special type of rules are then extracted from the selected itemsets. Our proposed rule mining method performs better than the other rule mining algorithms as it generates maximal frequent closed homogeneous itemsets instead of frequent itemsets. Thus, it saves elapsed time, and can work on big dataset. Pathway and Gene Ontology analyses are conducted on the genes of the evolved rules using David database. Frequency analysis of the genes appearing in the evolved rules is performed to determine potential biomarkers. Furthermore, we also classify the data to know how much the evolved rules are able to describe accurately the remaining test (unknown) data. Subsequently, we also compare the average classification accuracy, and other related factors with other rule-based classifiers. Statistical significance tests are also performed for verifying the statistical relevance of the comparative results. Here, each of the other rule mining methods or rule-based classifiers is also starting with the same post-discretized data-matrix. Finally, we have also included the integrated analysis of gene expression and methylation for determining epigenetic effect (viz., effect of methylation) on gene expression level.

  1. Efficacy of manual versus free-weight training to improve maximal strength and performance for microgravity conditions.

    PubMed

    Behringer, Michael; Schüren, Thomas; McCourt, Molly; Mester, Joachim

    2016-01-01

    We tested a simple and compact device designed for manual resistance training in conditions of microgravity (Self-Powered Rope Trainer Duo (SPoRT Duo)) to increase muscle performance. Twenty-four participants (20.8 ± 2.1 years) were randomly assigned to a manual resistance group (n = 12) and a free-weight group (n = 12). Participants performed eight exercises (three sets; 8-12 efforts) either with free weights or the SPoRT Duo twice a week for 6 weeks. Maximal isometric force of trunk flexion, back extension and chest press increased (P at least 0.01, d at least 0.52) both in the manual resistance group (18.4% ± 15.0%; 32.7% ± 22.7%; 15.3% ± 9.7%) and free-weight group (18.0% ± 13.9%; 26.6% ± 28.9%; 13.3% ± 7.6%). The change in maximal isometric force of wide grip row in both groups (d at best 0.38) did not reach statistical significance (P at best 0.08). The squat one-repetition-maximum increased in the manual resistance group (29.8% ± 22.1%) and the free-weight group (32.4% ± 26.6%). Jump height, determined by a jump-and-reach test, increased in the free-weight group (9.8% ± 13.2%) but not in the manual resistance group (2.0% ± 8.5%). Manual resistance training was equally effective in increasing strength as traditional resistance training with free weights. This apparatus is a useful addition to current in-flight exercise systems.

  2. Work and power outputs determined from pedalling and flywheel friction forces during brief maximal exertion on a cycle ergometer.

    PubMed

    Hibi, N; Fujinaga, H; Ishii, K

    1996-01-01

    Work and power outputs during short-term, maximal exertion on a friction loaded cycle ergometer are usually calculated from the friction force applied to the flywheel. The inertia of the flywheel is sometimes taken into consideration, but the effects of internal resistances and other factors have been ignored. The purpose of this study was to estimate their effects by comparing work or power output determined from the force exerted on the pedals (pedalling force) with work or power output determined from the friction force and the moment of inertia of the rotational parts. A group of 22 male college students accelerated a cycle ergometer as rapidly as possible for 3 s. The total work output determined from the pedalling force (TWp) was significantly greater than that calculated from the friction force and the moment of inertia (TWf). Power output determined from the pedalling force during each pedal stroke (SPp) was also significantly greater than that calculated from the friction force and the moment of inertia. Percentage difference (% diff), defined by % diff = ¿(TWp - TWf)/TWf¿ x 100, ranged from 16.8% to 49.3% with a mean value of 30.8 (SD 9.1)%. It was observed that % diff values were higher in subjects with greater TWp or greater maximal SPp. These results would indicate that internal resistances and other factors, such as the deformation of the chain and the vibrations of the entire system, may have significant effects on the measurements of work and power outputs. The effects appear to depend on the magnitudes of pedalling force and pedal velocity.

  3. Balancing Power Absorption and Structural Loading for an Asymmetric Heave Wave-Energy Converter in Regular Waves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tom, Nathan M.; Madhi, Farshad; Yeung, Ronald W.

    2016-06-24

    The aim of this paper is to maximize the power-to-load ratio of the Berkeley Wedge: a one-degree-of-freedom, asymmetrical, energy-capturing, floating breakwater of high performance that is relatively free of viscosity effects. Linear hydrodynamic theory was used to calculate bounds on the expected time-averaged power (TAP) and corresponding surge restraining force, pitch restraining torque, and power take-off (PTO) control force when assuming that the heave motion of the wave energy converter remains sinusoidal. This particular device was documented to be an almost-perfect absorber if one-degree-of-freedom motion is maintained. The success of such or similar future wave energy converter technologies would requiremore » the development of control strategies that can adapt device performance to maximize energy generation in operational conditions while mitigating hydrodynamic loads in extreme waves to reduce the structural mass and overall cost. This paper formulates the optimal control problem to incorporate metrics that provide a measure of the surge restraining force, pitch restraining torque, and PTO control force. The optimizer must now handle an objective function with competing terms in an attempt to maximize power capture while minimizing structural and actuator loads. A penalty weight is placed on the surge restraining force, pitch restraining torque, and PTO actuation force, thereby allowing the control focus to be placed either on power absorption or load mitigation. Thus, in achieving these goals, a per-unit gain in TAP would not lead to a greater per-unit demand in structural strength, hence yielding a favorable benefit-to-cost ratio. Demonstrative results in the form of TAP, reactive TAP, and the amplitudes of the surge restraining force, pitch restraining torque, and PTO control force are shown for the Berkeley Wedge example.« less

  4. Influence of running stride frequency in heart rate variability analysis during treadmill exercise testing.

    PubMed

    Bailón, Raquel; Garatachea, Nuria; de la Iglesia, Ignacio; Casajús, Jose Antonio; Laguna, Pablo

    2013-07-01

    The analysis and interpretation of heart rate variability (HRV) during exercise is challenging not only because of the nonstationary nature of exercise, the time-varying mean heart rate, and the fact that respiratory frequency exceeds 0.4 Hz, but there are also other factors, such as the component centered at the pedaling frequency observed in maximal cycling tests, which may confuse the interpretation of HRV analysis. The objectives of this study are to test the hypothesis that a component centered at the running stride frequency (SF) appears in the HRV of subjects during maximal treadmill exercise testing, and to study its influence in the interpretation of the low-frequency (LF) and high-frequency (HF) components of HRV during exercise. The HRV of 23 subjects during maximal treadmill exercise testing is analyzed. The instantaneous power of different HRV components is computed from the smoothed pseudo-Wigner-Ville distribution of the modulating signal assumed to carry information from the autonomic nervous system, which is estimated based on the time-varying integral pulse frequency modulation model. Besides the LF and HF components, the appearance is revealed of a component centered at the running SF as well as its aliases. The power associated with the SF component and its aliases represents 22±7% (median±median absolute deviation) of the total HRV power in all the subjects. Normalized LF power decreases as the exercise intensity increases, while normalized HF power increases. The power associated with the SF does not change significantly with exercise intensity. Consideration of the running SF component and its aliases is very important in HRV analysis since stride frequency aliases may overlap with LF and HF components.

  5. Analytical and numerical calculations of optimum design frequency for focused ultrasound therapy and acoustic radiation force.

    PubMed

    Ergün, A Sanlı

    2011-10-01

    Focused ultrasound therapy relies on acoustic power absorption by tissue. The stronger the absorption the higher the temperature increase is. However, strong acoustic absorption also means faster attenuation and limited penetration depth. Hence, there is a trade-off between heat generation efficacy and penetration depth. In this paper, we formulated the acoustic power absorption as a function of frequency and attenuation coefficient, and defined two figures of merit to measure the power absorption: spatial peak of the acoustic power absorption density, and the acoustic power absorbed within the focal area. Then, we derived "rule of thumb" expressions for the optimum frequencies that maximized these figures of merit given the target depth and homogeneous tissue type. We also formulated a method to calculate the optimum frequency for inhomogeneous tissue given the tissue composition for situations where the tissue structure can be assumed to be made of parallel layers of homogeneous tissue. We checked the validity of the rules using linear acoustic field simulations. For a one-dimensional array of 4cm acoustic aperture, and for a two-dimensional array of 4×4cm(2) acoustic aperture, we found that the power absorbed within the focal area is maximized at 0.86MHz, and 0.79MHz, respectively, when the target depth is 4cm in muscle tissue. The rules on the other hand predicted the optimum frequencies for acoustic power absorption as 0.9MHz and 0.86MHz, respectively for the 1D and 2D array case, which are within 6% and 9% of the field simulation results. Because radiation force generated by an acoustic wave in a lossy propagation medium is approximately proportional to the acoustic power absorption, these rules can be used to maximize acoustic radiation force generated in tissue as well. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. A nonlinear isobologram model with Box-Cox transformation to both sides for chemical mixtures.

    PubMed

    Chen, D G; Pounds, J G

    1998-12-01

    The linear logistical isobologram is a commonly used and powerful graphical and statistical tool for analyzing the combined effects of simple chemical mixtures. In this paper a nonlinear isobologram model is proposed to analyze the joint action of chemical mixtures for quantitative dose-response relationships. This nonlinear isobologram model incorporates two additional new parameters, Ymin and Ymax, to facilitate analysis of response data that are not constrained between 0 and 1, where parameters Ymin and Ymax represent the minimal and the maximal observed toxic response. This nonlinear isobologram model for binary mixtures can be expressed as [formula: see text] In addition, a Box-Cox transformation to both sides is introduced to improve the goodness of fit and to provide a more robust model for achieving homogeneity and normality of the residuals. Finally, a confidence band is proposed for selected isobols, e.g., the median effective dose, to facilitate graphical and statistical analysis of the isobologram. The versatility of this approach is demonstrated using published data describing the toxicity of the binary mixtures of citrinin and ochratoxin as well as a new experimental data from our laboratory for mixtures of mercury and cadmium.

  7. A nonlinear isobologram model with Box-Cox transformation to both sides for chemical mixtures.

    PubMed Central

    Chen, D G; Pounds, J G

    1998-01-01

    The linear logistical isobologram is a commonly used and powerful graphical and statistical tool for analyzing the combined effects of simple chemical mixtures. In this paper a nonlinear isobologram model is proposed to analyze the joint action of chemical mixtures for quantitative dose-response relationships. This nonlinear isobologram model incorporates two additional new parameters, Ymin and Ymax, to facilitate analysis of response data that are not constrained between 0 and 1, where parameters Ymin and Ymax represent the minimal and the maximal observed toxic response. This nonlinear isobologram model for binary mixtures can be expressed as [formula: see text] In addition, a Box-Cox transformation to both sides is introduced to improve the goodness of fit and to provide a more robust model for achieving homogeneity and normality of the residuals. Finally, a confidence band is proposed for selected isobols, e.g., the median effective dose, to facilitate graphical and statistical analysis of the isobologram. The versatility of this approach is demonstrated using published data describing the toxicity of the binary mixtures of citrinin and ochratoxin as well as a new experimental data from our laboratory for mixtures of mercury and cadmium. PMID:9860894

  8. Macroecological patterns of phytoplankton in the northwestern North Atlantic Ocean.

    PubMed

    Li, W K W

    2002-09-12

    Many issues in biological oceanography are regional or global in scope; however, there are not many data sets of extensive areal coverage for marine plankton. In microbial ecology, a fruitful approach to large-scale questions is comparative analysis wherein statistical data patterns are sought from different ecosystems, frequently assembled from unrelated studies. A more recent approach termed macroecology characterizes phenomena emerging from large numbers of biological units by emphasizing the shapes and boundaries of statistical distributions, because these reflect the constraints on variation. Here, I use a set of flow cytometric measurements to provide macroecological perspectives on North Atlantic phytoplankton communities. Distinct trends of abundance in picophytoplankton and both small and large nanophytoplankton underlaid two patterns. First, total abundance of the three groups was related to assemblage mean-cell size according to the 3/4 power law of allometric scaling in biology. Second, cytometric diversity (an ataxonomic measure of assemblage entropy) was maximal at intermediate levels of water column stratification. Here, intermediate disturbance shapes diversity through an equitable distribution of cells in size classes, from which arises a high overall biomass. By subsuming local fluctuations, macroecology reveals meaningful patterns of phytoplankton at large scales.

  9. Applying Probabilistic Decision Models to Clinical Trial Design

    PubMed Central

    Smith, Wade P; Phillips, Mark H

    2018-01-01

    Clinical trial design most often focuses on a single or several related outcomes with corresponding calculations of statistical power. We consider a clinical trial to be a decision problem, often with competing outcomes. Using a current controversy in the treatment of HPV-positive head and neck cancer, we apply several different probabilistic methods to help define the range of outcomes given different possible trial designs. Our model incorporates the uncertainties in the disease process and treatment response and the inhomogeneities in the patient population. Instead of expected utility, we have used a Markov model to calculate quality adjusted life expectancy as a maximization objective. Monte Carlo simulations over realistic ranges of parameters are used to explore different trial scenarios given the possible ranges of parameters. This modeling approach can be used to better inform the initial trial design so that it will more likely achieve clinical relevance. PMID:29888075

  10. Pharmacy benefit management contracting: an assessment from a recent public sector procurement experience.

    PubMed

    Bae, Jay P; Justice, Paul G

    2002-01-01

    In order to contain the cost of pharmaceuticals while preserving access to medically necessary drugs, Georgia state government competitively selected a single vendor in May of 2000 to manage combined pharmacy benefits under all of the state's health programs. By initiating this procedure, it intended to maximize the state's purchasing power and improve efficiency while streamlining the administrative structure. Synthesizing information from the request for proposal (RFP) and technical proposals submitted by 11 pharmacy benefit managers (PBMs) in response, we describe a model of public sector PBM contracting approach and present an assessment of the industry's service capability and performance statistics. Payers who have been using PBM services may find it interesting to compare their experience with the recent Georgia experience. Those who are considering contracting with a PBM will find the assessment of the PBM industry timely and informative.

  11. Determining the Statistical Power of the Kolmogorov-Smirnov and Anderson-Darling Goodness-of-Fit Tests via Monte Carlo Simulation

    DTIC Science & Technology

    2016-12-01

    KS and AD Statistical Power via Monte Carlo Simulation Statistical power is the probability of correctly rejecting the null hypothesis when the...Select a caveat DISTRIBUTION STATEMENT A. Approved for public release: distribution unlimited. Determining the Statistical Power...real-world data to test the accuracy of the simulation. Statistical comparison of these metrics can be necessary when making such a determination

  12. Evaluating the efficiency of environmental monitoring programs

    USGS Publications Warehouse

    Levine, Carrie R.; Yanai, Ruth D.; Lampman, Gregory G.; Burns, Douglas A.; Driscoll, Charles T.; Lawrence, Gregory B.; Lynch, Jason; Schoch, Nina

    2014-01-01

    Statistical uncertainty analyses can be used to improve the efficiency of environmental monitoring, allowing sampling designs to maximize information gained relative to resources required for data collection and analysis. In this paper, we illustrate four methods of data analysis appropriate to four types of environmental monitoring designs. To analyze a long-term record from a single site, we applied a general linear model to weekly stream chemistry data at Biscuit Brook, NY, to simulate the effects of reducing sampling effort and to evaluate statistical confidence in the detection of change over time. To illustrate a detectable difference analysis, we analyzed a one-time survey of mercury concentrations in loon tissues in lakes in the Adirondack Park, NY, demonstrating the effects of sampling intensity on statistical power and the selection of a resampling interval. To illustrate a bootstrapping method, we analyzed the plot-level sampling intensity of forest inventory at the Hubbard Brook Experimental Forest, NH, to quantify the sampling regime needed to achieve a desired confidence interval. Finally, to analyze time-series data from multiple sites, we assessed the number of lakes and the number of samples per year needed to monitor change over time in Adirondack lake chemistry using a repeated-measures mixed-effects model. Evaluations of time series and synoptic long-term monitoring data can help determine whether sampling should be re-allocated in space or time to optimize the use of financial and human resources.

  13. Optimization of power systems with voltage security constraints

    NASA Astrophysics Data System (ADS)

    Rosehart, William Daniel

    As open access market principles are applied to power systems, significant changes in their operation and control are occurring. In the new marketplace, power systems are operating under higher loading conditions as market influences demand greater attention to operating cost versus stability margins. Since stability continues to be a basic requirement in the operation of any power system, new tools are being considered to analyze the effect of stability on the operating cost of the system, so that system stability can be incorporated into the costs of operating the system. In this thesis, new optimal power flow (OPF) formulations are proposed based on multi-objective methodologies to optimize active and reactive power dispatch while maximizing voltage security in power systems. The effects of minimizing operating costs, minimizing reactive power generation and/or maximizing voltage stability margins are analyzed. Results obtained using the proposed Voltage Stability Constrained OPF formulations are compared and analyzed to suggest possible ways of costing voltage security in power systems. When considering voltage stability margins the importance of system modeling becomes critical, since it has been demonstrated, based on bifurcation analysis, that modeling can have a significant effect of the behavior of power systems, especially at high loading levels. Therefore, this thesis also examines the effects of detailed generator models and several exponential load models. Furthermore, because of its influence on voltage stability, a Static Var Compensator model is also incorporated into the optimization problems.

  14. A Joint Multitarget Estimator for the Joint Target Detection and Tracking Filter

    DTIC Science & Technology

    2015-06-27

    function is the information theoretic part of the problem and aims for entropy maximization, while the second one arises from the constraint in the...objective functions in conflict. The first objective function is the information theo- retic part of the problem and aims for entropy maximization...theory. For the sake of completeness and clarity, we also summarize how each concept is utilized later. Entropy : A random variable is statistically

  15. Statistical learning theory for high dimensional prediction: Application to criterion-keyed scale development.

    PubMed

    Chapman, Benjamin P; Weiss, Alexander; Duberstein, Paul R

    2016-12-01

    Statistical learning theory (SLT) is the statistical formulation of machine learning theory, a body of analytic methods common in "big data" problems. Regression-based SLT algorithms seek to maximize predictive accuracy for some outcome, given a large pool of potential predictors, without overfitting the sample. Research goals in psychology may sometimes call for high dimensional regression. One example is criterion-keyed scale construction, where a scale with maximal predictive validity must be built from a large item pool. Using this as a working example, we first introduce a core principle of SLT methods: minimization of expected prediction error (EPE). Minimizing EPE is fundamentally different than maximizing the within-sample likelihood, and hinges on building a predictive model of sufficient complexity to predict the outcome well, without undue complexity leading to overfitting. We describe how such models are built and refined via cross-validation. We then illustrate how 3 common SLT algorithms-supervised principal components, regularization, and boosting-can be used to construct a criterion-keyed scale predicting all-cause mortality, using a large personality item pool within a population cohort. Each algorithm illustrates a different approach to minimizing EPE. Finally, we consider broader applications of SLT predictive algorithms, both as supportive analytic tools for conventional methods, and as primary analytic tools in discovery phase research. We conclude that despite their differences from the classic null-hypothesis testing approach-or perhaps because of them-SLT methods may hold value as a statistically rigorous approach to exploratory regression. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  16. 78 FR 79401 - Export Trade Certificate of Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-30

    ... Power Equipment Institute, Inc. (Application no. 89- 5A018). SUMMARY: The U.S. Department of Commerce issued an amended Export Trade Certificate of Review to Outdoor Power Equipment Institute, Inc. (OPEI) on... Price Turf Equipment, Ingersoll Equipment Company, Kut-Kwick Corporation, Maxim Manufacturing...

  17. Multi-objective Extremum Seeking Control for Enhancement of Wind Turbine Power Capture with Load Reduction

    NASA Astrophysics Data System (ADS)

    Xiao, Yan; Li, Yaoyu; Rotea, Mario A.

    2016-09-01

    The primary objective in below rated wind speed (Region 2) is to maximize the turbine's energy capture. Due to uncertainty, variability of turbine characteristics and lack of inexpensive but precise wind measurements, model-free control strategies that do not use wind measurements such as Extremum Seeking Control (ESC) have received significant attention. Based on a dither-demodulation scheme, ESC can maximize the wind power capture in real time despite uncertainty, variabilities and lack of accurate wind measurements. The existing work on ESC based wind turbine control focuses on power capture only. In this paper, a multi-objective extremum seeking control strategy is proposed to achieve nearly optimum wind energy capture while decreasing structural fatigue loads. The performance index of the ESC combines the rotor power and penalty terms of the standard deviations of selected fatigue load variables. Simulation studies of the proposed multi-objective ESC demonstrate that the damage-equivalent loads of tower and/or blade loads can be reduced with slight compromise in energy capture.

  18. The evolution of offensive realism.

    PubMed

    Johnson, Dominic D P; Phil, D; Thayer, Bradley A

    Offensive realism, a theory of international relations, holds that states are disposed to competition and conflict because they are self-interested, power maximizing, and fearful of other states. Moreover, it argues that states are obliged to behave this way because doing so favors survival in the international system. Debate continues as to whether modern states actually do, or should, behave in this way, but we are struck by a different question. In this article, we ask whether the three core assumptions about behavior in offensive realism-self-help, power maximization, and outgroup fear-have any basis in scientific knowledge about human behavioral evolution. We find that these precise traits are not only evolutionarily adaptive but also empirically common across the animal kingdom, especially in primate and human societies. Based on these findings, we hypothesize that states behave as offensive realists predict not just because of anarchy in the modern international system but also because of the legacy of our evolution. In short, offensive realism may really be describing the nature of the human species more than the nature of the international system. If our hypothesis is correct, then evolutionary theory offers the following: (1) a novel ultimate cause of offensive realist behavior; (2) an extension of offensive realism to any domain in which humans compete for power; and (3) an explanation for why individual leaders themselves, and not just states, seek power. However, a key insight from evolution is that the primacy of self-help, power maximization, and outgroup fear does not necessarily condemn individuals or groups to competition and conflict; rather, these traits can in themselves give rise to cooperation and alliances.

  19. Modeling and Optimization of Coordinative Operation of Hydro-wind-photovoltaic Considering Power Generation and Output Fluctuation

    NASA Astrophysics Data System (ADS)

    Wang, Xianxun; Mei, Yadong

    2017-04-01

    Coordinative operation of hydro-wind-photovoltaic is the solution of mitigating the conflict of power generation and output fluctuation of new energy and conquering the bottleneck of new energy development. Due to the deficiencies of characterizing output fluctuation, depicting grid construction and disposal of power abandon, the research of coordinative mechanism is influenced. In this paper, the multi-object and multi-hierarchy model of coordinative operation of hydro-wind-photovoltaic is built with the aim of maximizing power generation and minimizing output fluctuation and the constraints of topotaxy of power grid and balanced disposal of power abandon. In the case study, the comparison of uncoordinative and coordinative operation is carried out with the perspectives of power generation, power abandon and output fluctuation. By comparison from power generation, power abandon and output fluctuation between separate operation and coordinative operation of multi-power, the coordinative mechanism is studied. Compared with running solely, coordinative operation of hydro-wind-photovoltaic can gain the compensation benefits. Peak-alternation operation reduces the power abandon significantly and maximizes resource utilization effectively by compensating regulation of hydropower. The Pareto frontier of power generation and output fluctuation is obtained through multiple-objective optimization. It clarifies the relationship of mutual influence between these two objects. When coordinative operation is taken, output fluctuation can be markedly reduced at the cost of a slight decline of power generation. The power abandon also drops sharply compared with operating separately. Applying multi-objective optimization method to optimize the coordinate operation, Pareto optimal solution set of power generation and output fluctuation is achieved.

  20. The Effects of a 10-Kilometer Run on Muscle Strength and Power.

    ERIC Educational Resources Information Center

    Gomez, Ana L.; Radzwich, Robert J.; Denegar, Craig R.; Volek, Jeff S.; Rubin, Martyn R.; Bush, Jill A.; Doan, Brandon K.; Wickham, Robbin B.; Mazzetti, Scott A.; Newton, Robert U.; French, Duncan N.; Hakkinen, Keijo; Ratamess, Nicholas A.; Kraemer, William J.

    2002-01-01

    Investigated recovery of maximal force and power following a 10-km race. Data collected on 10 healthy male distance runners pre-race, immediately post-race, and 48 hours later indicated that strength and power capabilities of these 10-km runners were for the most part restored 48 hours after the race. Only the hamstring muscle group was not fully…

  1. A Study of a Two Stage Maximum Power Point Tracking Control of a Photovoltaic System under Partially Shaded Insolation Conditions

    NASA Astrophysics Data System (ADS)

    Kobayashi, Kenji; Takano, Ichiro; Sawada, Yoshio

    A photovoltaic array shows relatively low output power density, and has a greatly drooping Current-Voltage (I-V) characteristic. Therefore, Maximum Power Point Tracking (MPPT) control is used to maximize the output power of the array. Many papers have been reported in relation to MPPT. However, the Current-Power (I-P) curve sometimes shows multi-local maximum points mode under non-uniform insolation conditions. The operating point of the PV system tends to converge to a local maximum output point which is not the real maximal output point on the I-P curve. Some papers have been also reported, trying to avoid this difficulty. However most of those control systems become rather complicated. Then, the two stage MPPT control method is proposed in this paper to realize a relatively simple control system which can track the real maximum power point even under non-uniform insolation conditions. The feasibility of this control concept is confirmed for steady insolation as well as for rapidly changing insolation by simulation study using software PSIM and LabVIEW. In addition, simulated experiment confirms fundament al operation of the two stage MPPT control.

  2. A Primer on the Statistical Modelling of Learning Curves in Health Professions Education

    ERIC Educational Resources Information Center

    Pusic, Martin V.; Boutis, Kathy; Pecaric, Martin R.; Savenkov, Oleksander; Beckstead, Jason W.; Jaber, Mohamad Y.

    2017-01-01

    Learning curves are a useful way of representing the rate of learning over time. Features include an index of baseline performance (y-intercept), the efficiency of learning over time (slope parameter) and the maximal theoretical performance achievable (upper asymptote). Each of these parameters can be statistically modelled on an individual and…

  3. Identifying Student Resources in Reasoning about Entropy and the Approach to Thermal Equilibrium

    ERIC Educational Resources Information Center

    Loverude, Michael

    2015-01-01

    As part of an ongoing project to examine student learning in upper-division courses in thermal and statistical physics, we have examined student reasoning about entropy and the second law of thermodynamics. We have examined reasoning in terms of heat transfer, entropy maximization, and statistical treatments of multiplicity and probability. In…

  4. Silent myocardial ischaemia: the Tan Tock Seng experience.

    PubMed

    Mak, K H; Tan, E K; Chew, L; Gan, S H; Chan, A L

    1991-10-01

    The results of treadmill exercise stress test (TMX) for ischaemia is based on ST-segment depression. Patients with positive test may or may not be symptomatic. This study examines if there are any differences between these two groups of patients. A total of thirty-nine patients with coronary artery disease and positive TMX results in 1988 was studied. There were 16 patients with chest pain and 23 without. They were followed-up for a mean period of 16.9 and 15.2 months respectively. The following factors were found not to be statistically significant between these two groups of patients: age, sex, race, height, weight, history of hypertension, diabetes mellitus or smoking, indication for the test, use of drugs, total and HDL-cholesterol, exercise duration and the initial double product. The difference between the maximal double product of the two groups was statistically significant (p = 0.004). In the follow-up period, in the group of patients with silent myocardial ischaemia, one had a cardiac event and one underwent revascularisation. While in the symptomatic group, two had cardiac events and seven underwent revascularisation. There were no deaths in either group. The difference in overall outcome was significant statistically (p = 0.002). Therefore, patients with silent myocardial ischaemia have a higher maximal double product in TMX; hence a higher maximal workload and a less adverse outcome compared to symptomatic patients.

  5. [The principal components analysis--method to classify the statistical variables with applications in medicine].

    PubMed

    Dascălu, Cristina Gena; Antohe, Magda Ecaterina

    2009-01-01

    Based on the eigenvalues and the eigenvectors analysis, the principal component analysis has the purpose to identify the subspace of the main components from a set of parameters, which are enough to characterize the whole set of parameters. Interpreting the data for analysis as a cloud of points, we find through geometrical transformations the directions where the cloud's dispersion is maximal--the lines that pass through the cloud's center of weight and have a maximal density of points around them (by defining an appropriate criteria function and its minimization. This method can be successfully used in order to simplify the statistical analysis on questionnaires--because it helps us to select from a set of items only the most relevant ones, which cover the variations of the whole set of data. For instance, in the presented sample we started from a questionnaire with 28 items and, applying the principal component analysis we identified 7 principal components--or main items--fact that simplifies significantly the further data statistical analysis.

  6. Finding the quantum thermoelectric with maximal efficiency and minimal entropy production at given power output

    NASA Astrophysics Data System (ADS)

    Whitney, Robert S.

    2015-03-01

    We investigate the nonlinear scattering theory for quantum systems with strong Seebeck and Peltier effects, and consider their use as heat engines and refrigerators with finite power outputs. This paper gives detailed derivations of the results summarized in a previous paper [R. S. Whitney, Phys. Rev. Lett. 112, 130601 (2014), 10.1103/PhysRevLett.112.130601]. It shows how to use the scattering theory to find (i) the quantum thermoelectric with maximum possible power output, and (ii) the quantum thermoelectric with maximum efficiency at given power output. The latter corresponds to a minimal entropy production at that power output. These quantities are of quantum origin since they depend on system size over electronic wavelength, and so have no analog in classical thermodynamics. The maximal efficiency coincides with Carnot efficiency at zero power output, but decreases with increasing power output. This gives a fundamental lower bound on entropy production, which means that reversibility (in the thermodynamic sense) is impossible for finite power output. The suppression of efficiency by (nonlinear) phonon and photon effects is addressed in detail; when these effects are strong, maximum efficiency coincides with maximum power. Finally, we show in particular limits (typically without magnetic fields) that relaxation within the quantum system does not allow the system to exceed the bounds derived for relaxation-free systems, however, a general proof of this remains elusive.

  7. Energy Systems Integration Facility Videos | Energy Systems Integration

    Science.gov Websites

    Facility | NREL Energy Systems Integration Facility Videos Energy Systems Integration Facility Integration Facility NREL + SolarCity: Maximizing Solar Power on Electrical Grids Redefining What's Possible for Renewable Energy: Grid Integration Robot-Powered Reliability Testing at NREL's ESIF Microgrid

  8. Method of optimizing performance of Rankine cycle power plants

    DOEpatents

    Pope, William L.; Pines, Howard S.; Doyle, Padraic A.; Silvester, Lenard F.

    1982-01-01

    A method for efficiently operating a Rankine cycle power plant (10) to maximize fuel utilization efficiency or energy conversion efficiency or minimize costs by selecting a turbine (22) fluid inlet state which is substantially in the area adjacent and including the transposed critical temperature line (46).

  9. Analytic model for ultrasound energy receivers and their optimal electric loads II: Experimental validation

    NASA Astrophysics Data System (ADS)

    Gorostiaga, M.; Wapler, M. C.; Wallrabe, U.

    2017-10-01

    In this paper, we verify the two optimal electric load concepts based on the zero reflection condition and on the power maximization approach for ultrasound energy receivers. We test a high loss 1-3 composite transducer, and find that the measurements agree very well with the predictions of the analytic model for plate transducers that we have developed previously. Additionally, we also confirm that the power maximization and zero reflection loads are very different when the losses in the receiver are high. Finally, we compare the optimal load predictions by the KLM and the analytic models with frequency dependent attenuation to evaluate the influence of the viscosity.

  10. Analytic model for ultrasound energy receivers and their optimal electric loads

    NASA Astrophysics Data System (ADS)

    Gorostiaga, M.; Wapler, M. C.; Wallrabe, U.

    2017-08-01

    In this paper, we present an analytic model for thickness resonating plate ultrasound energy receivers, which we have derived from the piezoelectric and the wave equations and, in which we have included dielectric, viscosity and acoustic attenuation losses. Afterwards, we explore the optimal electric load predictions by the zero reflection and power maximization approaches present in the literature with different acoustic boundary conditions, and discuss their limitations. To validate our model, we compared our expressions with the KLM model solved numerically with very good agreement. Finally, we discuss the differences between the zero reflection and power maximization optimal electric loads, which start to differ as losses in the receiver increase.

  11. Maximizing Computational Capability with Minimal Power

    DTIC Science & Technology

    2009-03-01

    Chip -Scale Energy and Power... and Heat Report Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden for the collection of...OpticalBench Mounting Posts Imager Chip LCDinterfaced withthecomputer P o l a r i z e r P o l a r i z e r XYZ Translator Optical Slide VMM Computational Pixel...Signal routing power / memory: ? Power does not include comm off chip (i.e. accessing memory) Power = ½ C Vdd2 f for CMOS Chip to Chip (10pF load min

  12. Determinants of maximal oxygen uptake (VO2 max) in fire fighter testing.

    PubMed

    Vandersmissen, G J M; Verhoogen, R A J R; Van Cauwenbergh, A F M; Godderis, L

    2014-07-01

    The aim of this study was to evaluate current daily practice of aerobic capacity testing in Belgian fire fighters. The impact of personal and test-related parameters on the outcome has been evaluated. Maximal oxygen uptake (VO2 max) results of 605 male fire fighters gathered between 1999 and 2010 were analysed. The maximal cardio respiratory exercise tests were performed at 22 different centres using different types of tests (tread mill or bicycle), different exercise protocols and measuring equipment. Mean VO2 max was 43.3 (SD = 9.8) ml/kg.min. Besides waist circumference and age, the type of test, the degree of performance of the test and the test centre were statistically significant determinants of maximal oxygen uptake. Test-related parameters have to be taken into account when interpreting and comparing maximal oxygen uptake tests of fire fighters. It highlights the need for standardization of aerobic capacity testing in the medical evaluation of fire fighters. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  13. Physiological characteristics of an aging Olympic athlete.

    PubMed

    Nybo, Lars; Schmidt, Jakob F; Fritzdorf, Stephen; Nordsborg, Nikolai B

    2014-11-01

    To investigate the physiological basis of continued world-class performance of a world-class rower who won medals (three gold and two bronze) at five consecutive Olympic Games. From the age of 19 to 40 yr, maximal oxygen uptake (VO2 max), peak HR, blood lactate, and rowing ergometer performance were assessed annually. During the first years of his elite career (from age 19 to 24), VO2 max increased from 5.5 to approximately 5.9 L · min(-1) (78 mL · min(-1) · kg(-1)) and his average power during 6-min maximal rowing increased from 420 to approximately 460 W. Although his HRmax declined by approximately 20 bpm during the 20-yr period, maximal aerobic power, evaluated both as VO2 max and 6-min test performance, was maintained until the age of 40. Furthermore, peak lactate levels remained unchanged and average power outputs during 10-s, 60-s, and 60-min ergometer tests were all maintained at approximately 800 W, approximately 700 W, and approximately 350 W, respectively, indicating that he was able to preserve both aerobic and anaerobic exercise performances. Echocardiographic analyses revealed a left ventricular mass of 198 g and left ventricular end-diastolic diameter of 5.8 cm. This longitudinal case indicates that until the age of 40 yr, a steady increase in the oxygen pulse may have compensated for the significant decline in the maximal heart frequency. Furthermore, the maintenance of aerobic and anaerobic exercise capacities allowed this Olympic athlete to compete at the highest level for almost two decades.

  14. The t-CWT: a new ERP detection and quantification method based on the continuous wavelet transform and Student's t-statistics.

    PubMed

    Bostanov, Vladimir; Kotchoubey, Boris

    2006-12-01

    This study was aimed at developing a method for extraction and assessment of event-related brain potentials (ERP) from single-trials. This method should be applicable in the assessment of single persons' ERPs and should be able to handle both single ERP components and whole waveforms. We adopted a recently developed ERP feature extraction method, the t-CWT, for the purposes of hypothesis testing in the statistical assessment of ERPs. The t-CWT is based on the continuous wavelet transform (CWT) and Student's t-statistics. The method was tested in two ERP paradigms, oddball and semantic priming, by assessing individual-participant data on a single-trial basis, and testing the significance of selected ERP components, P300 and N400, as well as of whole ERP waveforms. The t-CWT was also compared to other univariate and multivariate ERP assessment methods: peak picking, area computation, discrete wavelet transform (DWT) and principal component analysis (PCA). The t-CWT produced better results than all of the other assessment methods it was compared with. The t-CWT can be used as a reliable and powerful method for ERP-component detection and testing of statistical hypotheses concerning both single ERP components and whole waveforms extracted from either single persons' or group data. The t-CWT is the first such method based explicitly on the criteria of maximal statistical difference between two average ERPs in the time-frequency domain and is particularly suitable for ERP assessment of individual data (e.g. in clinical settings), but also for the investigation of small and/or novel ERP effects from group data.

  15. Muscular Strength and Power in 3-to 7-Year-Old Children.

    PubMed

    Fry, Andrew C; Irwin, Carol C; Nicoll, Justin X; Ferebee, David E

    2015-08-01

    To determine absolute and relative (adjusted for body mass) strength, mean power, and mean velocity for upper and lower body resistance exercises, forty-seven young boys and girls participated in maximal strength testing. Healthy young boys and girls, ages 3- to 7-years old, were tested for one-repetition maximum (1-RM) strength, and 70% of 1-RM to determine mean power and mean velocity on the chest press and leg press exercises. Adult weight machines were modified to accommodate the smaller size and lower strength levels of the children. A 2 × 4 (sex × age) ANOVA was used to determine age and sex differences in performance. No interaction or sex differences were observed for any variable at any age. 1-RM strength, mean power, and mean velocity significantly increased across ages (p ≤ .05). When adjusted for body mass, the changes were insignificant, with one exception. Relative mean power for the bench press increased with age. Data indicated children from 3-7 years of age are capable of performing strength and power tests, but may require more attempts at maximal loads compared with adults. It appears that muscular strength and velocity during this stage of development are primarily dependent on increasing body mass, whereas power is influenced by additional variable(s).

  16. The influence of surface on the running velocities of elite and amateur orienteer athletes.

    PubMed

    Hébert-Losier, K; Jensen, K; Mourot, L; Holmberg, H-C

    2014-12-01

    We compared the reduction in running velocities from road to off-road terrain in eight elite and eight amateur male orienteer athletes to investigate whether this factor differentiates elite from amateur athletes. On two separate days, each subject ran three 2-km time trials and three 20-m sprints "all-out" on a road, on a path, and in a forest. On a third day, the running economy and maximal aerobic power of individuals were assessed on a treadmill. The elite orienteer ran faster than the amateur on all three surfaces and at both distances, in line with their better running economy and aerobic power. In the forest, the elites ran at a slightly higher percentage of their 2-km (∼3%) and 20-m (∼4%) road velocities. Although these differences did not exhibit traditional statistical significance, magnitude-based inferences suggested likely meaningful differences, particularly during 20-m sprinting. Of course, cognitive, mental, and physical attributes other than the ability to run on different surfaces are required for excellence in orienteering (e.g., a high aerobic power). However, we suggest that athlete-specific assessment of running performance on various surfaces and distances might assist in tailoring training and identifying individual strengths and/or weaknesses in an orienteer. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Investigation on ultrasonication mediated biosurfactant disintegration method in sludge flocs for enhancing hydrolytic enzymes activity and polyhydroxyalkanoates.

    PubMed

    Sethupathy, A; Sivashanmugam, P

    2018-06-04

    In this study, a novel biosurfactant potential bacterial strain Pseudomonas pachastrellae RW43 was isolated from pulp and paper sludge and the biosurfactant namely rhamnolipid produced by Pseudomonas pachastrellae RW43 was investigated by varying pH and incubation time in batch liquid fermentation process. The maximal yield of rhamnolipid was found to be 12.1 g/L at an optimized condition of pH 7 and incubation time of 168 h. NMR analysis was performed for identification of molecular structure of produced rhamnolipid and its results concluded that the product was identified as di rhamnolipid. Then, statistically the global optimum conditions for hydrolytic enzymes extraction parameters (sonication power (100 W), extraction time (15 min) and rhamnolipid dosage (2% v/v)) were established. At 30,456 kJ/kg TS specific energy, ultrasonication with rhamnolipid disintegration method extracted maximal consortium activity of hydrolytic enzymes from mixed sludge (municipal and pulp & paper sludge) and the maximum observed were found to be 42.22, 51.75, 34.26, 24.21, 11.35 Units/g VSS respectively for protease, α-amylase, cellulase, lipase and α-glucosidase. Polyhydroxyalkanoates was recovered from enzymes extracted sludge using various solvents namely chloroform, sodium hypochlorite with chloroform and sodium lauryl sulfate with sodium hypochlorite. The maximum recovery was found to be 74 g/kg using sodium hypochlorite and chloroform extraction solvents.

  18. Teaching the principles of statistical dynamics

    PubMed Central

    Ghosh, Kingshuk; Dill, Ken A.; Inamdar, Mandar M.; Seitaridou, Effrosyni; Phillips, Rob

    2012-01-01

    We describe a simple framework for teaching the principles that underlie the dynamical laws of transport: Fick’s law of diffusion, Fourier’s law of heat flow, the Newtonian viscosity law, and the mass-action laws of chemical kinetics. In analogy with the way that the maximization of entropy over microstates leads to the Boltzmann distribution and predictions about equilibria, maximizing a quantity that E. T. Jaynes called “caliber” over all the possible microtrajectories leads to these dynamical laws. The principle of maximum caliber also leads to dynamical distribution functions that characterize the relative probabilities of different microtrajectories. A great source of recent interest in statistical dynamics has resulted from a new generation of single-particle and single-molecule experiments that make it possible to observe dynamics one trajectory at a time. PMID:23585693

  19. Teaching the principles of statistical dynamics.

    PubMed

    Ghosh, Kingshuk; Dill, Ken A; Inamdar, Mandar M; Seitaridou, Effrosyni; Phillips, Rob

    2006-02-01

    We describe a simple framework for teaching the principles that underlie the dynamical laws of transport: Fick's law of diffusion, Fourier's law of heat flow, the Newtonian viscosity law, and the mass-action laws of chemical kinetics. In analogy with the way that the maximization of entropy over microstates leads to the Boltzmann distribution and predictions about equilibria, maximizing a quantity that E. T. Jaynes called "caliber" over all the possible microtrajectories leads to these dynamical laws. The principle of maximum caliber also leads to dynamical distribution functions that characterize the relative probabilities of different microtrajectories. A great source of recent interest in statistical dynamics has resulted from a new generation of single-particle and single-molecule experiments that make it possible to observe dynamics one trajectory at a time.

  20. Hospital adoption of medical technology: an empirical test of alternative models.

    PubMed Central

    Teplensky, J. D.; Pauly, M. V.; Kimberly, J. R.; Hillman, A. L.; Schwartz, J. S.

    1995-01-01

    OBJECTIVE. This study examines hospital motivations to acquire new medical technology, an issue of considerable policy relevance: in this case, whether, when, and why hospitals acquire a new capital-intensive medical technology, magnetic resonance imaging equipment (MRI). STUDY DESIGN. We review three common explanations for medical technology adoption: profit maximization, technological preeminence, and clinical excellence, and incorporate them into a composite model, controlling for regulatory differences, market structures, and organizational characteristics. All four models are then tested using Cox regressions. DATA SOURCES. The study is based on an initial sample of 637 hospitals in the continental United States that owned or leased an MRI unit as of 31 December 1988, plus nonadopters. Due to missing data the final sample consisted of 507 hospitals. The data, drawn from two telephone surveys, are supplemented by the AHA Survey, census data, and industry and academic sources. PRINCIPAL FINDING. Statistically, the three individual models account for roughly comparable amounts of variance in past adoption behavior. On the basis of explanatory power and parsimony, however, the technology model is "best." Although the composite model is statistically better than any of the individual models, it does not add much more explanatory power adjusting for the number of variables added. CONCLUSIONS. The composite model identified the importance a hospital attached to being a technological leader, its clinical requirements, and the change in revenues it associated with the adoption of MRI as the major determinants of adoption behavior. We conclude that a hospital's adoption behavior is strongly linked to its strategic orientation. PMID:7649751

  1. Illustrating, Quantifying, and Correcting for Bias in Post-hoc Analysis of Gene-Based Rare Variant Tests of Association

    PubMed Central

    Grinde, Kelsey E.; Arbet, Jaron; Green, Alden; O'Connell, Michael; Valcarcel, Alessandra; Westra, Jason; Tintle, Nathan

    2017-01-01

    To date, gene-based rare variant testing approaches have focused on aggregating information across sets of variants to maximize statistical power in identifying genes showing significant association with diseases. Beyond identifying genes that are associated with diseases, the identification of causal variant(s) in those genes and estimation of their effect is crucial for planning replication studies and characterizing the genetic architecture of the locus. However, we illustrate that straightforward single-marker association statistics can suffer from substantial bias introduced by conditioning on gene-based test significance, due to the phenomenon often referred to as “winner's curse.” We illustrate the ramifications of this bias on variant effect size estimation and variant prioritization/ranking approaches, outline parameters of genetic architecture that affect this bias, and propose a bootstrap resampling method to correct for this bias. We find that our correction method significantly reduces the bias due to winner's curse (average two-fold decrease in bias, p < 2.2 × 10−6) and, consequently, substantially improves mean squared error and variant prioritization/ranking. The method is particularly helpful in adjustment for winner's curse effects when the initial gene-based test has low power and for relatively more common, non-causal variants. Adjustment for winner's curse is recommended for all post-hoc estimation and ranking of variants after a gene-based test. Further work is necessary to continue seeking ways to reduce bias and improve inference in post-hoc analysis of gene-based tests under a wide variety of genetic architectures. PMID:28959274

  2. Expected Power-Utility Maximization Under Incomplete Information and with Cox-Process Observations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fujimoto, Kazufumi, E-mail: m_fuji@kvj.biglobe.ne.jp; Nagai, Hideo, E-mail: nagai@sigmath.es.osaka-u.ac.jp; Runggaldier, Wolfgang J., E-mail: runggal@math.unipd.it

    2013-02-15

    We consider the problem of maximization of expected terminal power utility (risk sensitive criterion). The underlying market model is a regime-switching diffusion model where the regime is determined by an unobservable factor process forming a finite state Markov process. The main novelty is due to the fact that prices are observed and the portfolio is rebalanced only at random times corresponding to a Cox process where the intensity is driven by the unobserved Markovian factor process as well. This leads to a more realistic modeling for many practical situations, like in markets with liquidity restrictions; on the other hand itmore » considerably complicates the problem to the point that traditional methodologies cannot be directly applied. The approach presented here is specific to the power-utility. For log-utilities a different approach is presented in Fujimoto et al. (Preprint, 2012).« less

  3. Sprint interval training (SIT) substantially reduces depressive symptoms in major depressive disorder (MDD): A randomized controlled trial.

    PubMed

    Minghetti, Alice; Faude, Oliver; Hanssen, Henner; Zahner, Lukas; Gerber, Markus; Donath, Lars

    2018-07-01

    Continuous aerobic exercise training (CAT) is considered a complementary treatment option in patients with major depressive disorder (MDD). Intermittent exercise training protocols, such as sprint interval training (SIT) have gained increasing popularity, but no studies on depressive symptoms following SIT in patients with MDD are available. Fifty-nine in-patients with MDD were randomly assigned to a SIT or CAT group. Medication was counterbalanced in both intervention arms. Both intervention groups received 3 weekly training sessions for 4-weeks (12 sessions in total). SIT comprised 25 bouts of 30 seconds at 80% of maximal power, whereas CAT consisted of 20 minutes of physical activity at 60% of maximal power. The training protocols were isocalorically designed. Maximal bicycle ergometer exercise testing yielded maximal and submaximal physical fitness parameters. The Beck-Depression-Inventory-II (BDI-II) was filled out by the patients before and after the intervention period. BDI-II scores substantially decreased in both groups with an effect size pointing towards a large effect (p < 0.001, η p ² = 0.70) while submaximal (0.07 < d < 0.89) and maximal (0.05 < d < 0.85) fitness variables improved in both groups. Short-term SIT leads to similar results as CAT in patients with MDD and can be regarded as a time-efficient and promising exercise-based treatment strategy. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. A Gender-Based Kinematic and Kinetic Analysis of the Snatch Lift In Elite Weightlifters in 69-Kg Category

    PubMed Central

    Harbili, Erbil

    2012-01-01

    The objective of this study was to compare the kinematic and kinetic differences in snatch performances of elite 69-kg men and women weightlifters, the only category common to both genders. The heaviest lifts performed by 9 men and 9 women weightlifters competing in 69-kg weight class in Group A in the 2010 World Weightlifting Championship were analyzed. The snatch lifts were recorded using 2 cameras (PAL). Points on the barbell and body were manually digitized by using Ariel Performance Analysis System. The results showed that maximal extension angle of the ankle and knee during the first pull, the knee angle at the end of the transition phase, and maximal extension angle of the knee in the second pull were significantly greater in men (p < 0.05). The angular velocity of the hip was significantly greater in men during the first pull (p < 0.05). During the second pull, women showed significantly greater maximal angular velocity at the hip and ankle joints (p < 0.05). Moreover, the maximal vertical linear velocity of the barbell was significantly greater in women (p < 0.05). The absolute mechanical work and power output in the first pull and power output in the second pull were significantly greater in men (p < 0.05). However, the relative mechanical work was significantly greater in women during the second pull (p < 0.05). The results revealed that in 69-kg weight class, women were less efficient than men in the first pull, which is strength oriented, whereas they were as efficient as men in the second pull, which is more power oriented. Key points Women weightlifters should do assistant exercises to strengthen their ankle flexor and knee extensor muscles in order to increase their maximal strength in the first pull. Women weightlifters should be able to execute a deeper and faster knee flexion in the transition phase in order to obtain a greater explosive strength during the second pull. PMID:24149133

  5. Effects of synchronous versus asynchronous mode of propulsion on wheelchair basketball sprinting.

    PubMed

    Faupin, Arnaud; Borel, Benoit; Meyer, Christophe; Gorce, Philippe; Watelain, Eric

    2013-11-01

    This study aimed to first investigate synchronous (SYN) versus asynchronous (ASY) mode of propulsion and, second, investigate the wheel camber effects on sprinting performance as well as temporal parameters. Seven wheelchair basketball players performed four maximal eight-second sprints on a wheelchair ergometer. They repeated the test according to two modes of propulsion (SYN and ASY) and two wheel cambers (9° and 15°). The mean maximal velocity and push power output was greater in the synchronous mode compared to the asynchronous mode for both camber angles. However, the fluctuation in the velocity profile is inferior for ASY versus SYN mode for both camber angles. Greater push time/cycle time (Pt/Ct) and arm frequency (AF) for synchronous mode versus asynchronous mode and inversely, lesser Ct and rest time (Rt) values for the synchronous mode, for which greater velocity were observed. SYN mode leads to better performance than ASY mode in terms of maximal propulsion velocity. However, ASY propulsion allows greater continuity of the hand-rim force application, reducing fluctuations in the velocity profile. The camber angle had no effect on ASY and SYN mean maximal velocity and push power output. The study of wheelchair propulsion strategies is important for better understanding physiological and biomechanical impacts of wheelchair propulsion for individuals with disabilities. From a kinematical point of view, this study highlights synchronous mode of propulsion to be more efficient, with regards to mean maximal velocity reaching during maximal sprinting exercises. Even if this study focuses on well-trained wheelchair athletes, results from this study could complement the knowledge on the physiological and biomechanical adaptations to wheelchair propulsion and therefore, might be interesting for wheelchair modifications for purposes of rehabilitation.

  6. Predictive ability of a comprehensive incremental test in mountain bike marathon.

    PubMed

    Ahrend, Marc-Daniel; Schneeweiss, Patrick; Martus, Peter; Niess, Andreas M; Krauss, Inga

    2018-01-01

    Traditional performance tests in mountain bike marathon (XCM) primarily quantify aerobic metabolism and may not describe the relevant capacities in XCM. We aimed to validate a comprehensive test protocol quantifying its intermittent demands. Forty-nine athletes (38.8±9.1 years; 38 male; 11 female) performed a laboratory performance test, including an incremental test, to determine individual anaerobic threshold (IAT), peak power output (PPO) and three maximal efforts (10 s all-out sprint, 1 min maximal effort and 5 min maximal effort). Within 2 weeks, the athletes participated in one of three XCM races (n=15, n=9 and n=25). Correlations between test variables and race times were calculated separately. In addition, multiple regression models of the predictive value of laboratory outcomes were calculated for race 3 and across all races (z-transformed data). All variables were correlated with race times 1, 2 and 3: 10 s all-out sprint (r=-0.72; r=-0.59; r=-0.61), 1 min maximal effort (r=-0.85; r=-0.84; r=-0.82), 5 min maximal effort (r=-0.57; r=-0.85; r=-0.76), PPO (r=-0.77; r=-0.73; r=-0.76) and IAT (r=-0.71; r=-0.67; r=-0.68). The best-fitting multiple regression models for race 3 (r 2 =0.868) and across all races (r 2 =0.757) comprised 1 min maximal effort, IAT and body weight. Aerobic and intermittent variables correlated least strongly with race times. Their use in a multiple regression model confirmed additional explanatory power to predict XCM performance. These findings underline the usefulness of the comprehensive incremental test to predict performance in that sport more precisely.

  7. Maximization of the annual energy production of wind power plants by optimization of layout and yaw-based wake control: Maximization of wind plant AEP by optimization of layout and wake control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gebraad, Pieter; Thomas, Jared J.; Ning, Andrew

    This paper presents a wind plant modeling and optimization tool that enables the maximization of wind plant annual energy production (AEP) using yaw-based wake steering control and layout changes. The tool is an extension of a wake engineering model describing the steady-state effects of yaw on wake velocity profiles and power productions of wind turbines in a wind plant. To make predictions of a wind plant's AEP, necessary extensions of the original wake model include coupling it with a detailed rotor model and a control policy for turbine blade pitch and rotor speed. This enables the prediction of power productionmore » with wake effects throughout a range of wind speeds. We use the tool to perform an example optimization study on a wind plant based on the Princess Amalia Wind Park. In this case study, combined optimization of layout and wake steering control increases AEP by 5%. The power gains from wake steering control are highest for region 1.5 inflow wind speeds, and they continue to be present to some extent for the above-rated inflow wind speeds. The results show that layout optimization and wake steering are complementary because significant AEP improvements can be achieved with wake steering in a wind plant layout that is already optimized to reduce wake losses.« less

  8. Hovering efficiency comparison of rotary and flapping flight for rigid rectangular wings via dimensionless multi-objective optimization.

    PubMed

    Bayiz, Yagiz; Ghanaatpishe, Mohammad; Fathy, Hosam; Cheng, Bo

    2018-05-08

    In this work, a multi-objective optimization framework is developed for optimizing low Reynolds number ([Formula: see text]) hovering flight. This framework is then applied to compare the efficiency of rigid revolving and flapping wings with rectangular shape under varying [Formula: see text] and Rossby number ([Formula: see text], or aspect ratio). The proposed framework is capable of generating sets of optimal solutions and Pareto fronts for maximizing the lift coefficient and minimizing the power coefficient in dimensionless space, explicitly revealing the trade-off between lift generation and power consumption. The results indicate that revolving wings are more efficient when the required average lift coefficient [Formula: see text] is low (<1 for [Formula: see text] and  <1.6 for [Formula: see text]), while flapping wings are more efficient in achieving higher [Formula: see text]. With the dimensionless power loading as the single-objective performance measure to be maximized, rotary flight is more efficient than flapping wings for [Formula: see text] regardless of the amount of energy storage assumed in the flapping wing actuation mechanism, while flapping flight is more efficient for [Formula: see text]. It is observed that wings with low [Formula: see text] perform better when higher [Formula: see text] is needed, whereas higher [Formula: see text] cases are more efficient at [Formula: see text] regions. However, for the selected geometry and [Formula: see text], the efficiency is weakly dependent on [Formula: see text] when the dimensionless power loading is maximized.

  9. Mechanical Properties of Sprinting in Elite Rugby Union and Rugby League.

    PubMed

    Cross, Matt R; Brughelli, Matt; Brown, Scott R; Samozino, Pierre; Gill, Nicholas D; Cronin, John B; Morin, Jean-Benoît

    2015-09-01

    To compare mechanical properties of overground sprint running in elite rugby union and rugby league athletes. Thirty elite rugby code (15 rugby union and 15 rugby league) athletes participated in this cross-sectional analysis. Radar was used to measure maximal overground sprint performance over 20 or 30 m (forwards and backs, respectively). In addition to time at 2, 5, 10, 20, and 30 m, velocity-time signals were analyzed to derive external horizontal force-velocity relationships with a recently validated method. From this relationship, the maximal theoretical velocity, external relative and absolute horizontal force, horizontal power, and optimal horizontal force for peak power production were determined. While differences in maximal velocity were unclear between codes, rugby union backs produced moderately faster split times, with the most substantial differences occurring at 2 and 5 m (ES 0.95 and 0.86, respectively). In addition, rugby union backs produced moderately larger relative horizontal force, optimal force, and peak power capabilities than rugby league backs (ES 0.73-0.77). Rugby union forwards had a higher absolute force (ES 0.77) despite having ~12% more body weight than rugby league forwards. In this elite sample, rugby union athletes typically displayed greater short-distance sprint performance, which may be linked to an ability to generate high levels of horizontal force and power. The acceleration characteristics presented in this study could be a result of the individual movement and positional demands of each code.

  10. A new dose of maximal-intensity interval training in hypoxia to improve body composition and hemoglobin and hematocrit levels: a pilot study.

    PubMed

    Camacho-Cardenosa, Marta; Camacho-Cardenosa, Alba; Martínez Guardado, Ismael; Marcos-Serrano, Marta; Timon, Rafael; Olcina, Guillermo

    2017-01-01

    This pilot study had the aim to determine the effects of a new dose of maximal-intensity interval training in hypoxia in active adults. Twenty-four university student volunteers were randomly assigned to three groups: hypoxia group, normoxia group or control group. The eight training sessions consisted of 2 sets of 5 repeated sprints of 10 seconds with a recovery of 20 seconds between sprints and a recovery period of 10 minutes between sets. Body composition was measured following standard procedures. A blood sample was taken for an immediate hematocrit (HCT) and hemoglobin (Hb) concentration assessment. An all-out 3-ute test was performed to evaluate ventilation parameters and power. HCT and Hb were significantly higher for the hypoxia group in Post- and Det- (P=0.01; P=0.03). Fat mass percentage was significantly lower for the hypoxia group in both assessments (P=0.05; P=0.05). The hypoxia group underwent a significant increase in mean power after the recovery period. A new dose of 8 sessions of maximal-intensity interval training in hypoxia is enough to decrease the percentage of fat mass and to improve HCT and Hb parameters and mean muscle power in healthy and active adults.

  11. The feasibility of measuring joint angular velocity with a gyro-sensor.

    PubMed

    Arai, Takeshi; Obuchi, Shuichi; Shiba, Yoshitaka; Omuro, Kazuya; Nakano, Chika; Higashi, Takuya

    2008-01-01

    To determine the reliability of an assessment of joint angular velocity using a gyro-sensor and to examine the relationship between ankle angular velocity and physical functions. Cross-sectional. Kinesiology laboratory. Twenty healthy young adults (mean age, 22.5 y) and 113 community-dwelling older adults (mean age, 75.1 y). Not applicable. Maximal ankle joint velocity was measured using a gyro-sensor during heel-rising and jumping with knee extended. The intraclass correlation coefficient (ICC) was used to determine the intertester and intratester reliability. The Pearson correlation coefficient was used to examine the relationships between maximal ankle joint velocity and isometric muscle strength and isokinetic muscle power in young adults and also to examine the relationships between maximal ankle joint velocity and functional performance measurements such as walking time in older adults. High reliability was found for intertester (ICC=.96) and intratester reliability (ICC=.96). The data from the gyro-sensor highly correlated with muscle strength (r range, .62-.68; P<.01) and muscle power (r range, .45-.79; P range, .01-.05). In older subjects, mobility functions significantly correlated with the angular velocity of ankle plantarflexion. Measurement of ankle angular velocity using a gyro-sensor is both reliable and feasible, with the results representing a significant correlation to muscle power and performance measurements.

  12. Method of optimizing performance of Rankine cycle power plants. [US DOE Patent

    DOEpatents

    Pope, W.L.; Pines, H.S.; Doyle, P.A.; Silvester, L.F.

    1980-06-23

    A method is described for efficiently operating a Rankine cycle power plant to maximize fuel utilization efficiency or energy conversion efficiency or minimize costs by selecting a turbine fluid inlet state which is substantially on the area adjacent and including the transposed critical temperature line.

  13. Caffeine improves muscular performance in elite Brazilian Jiu-jitsu athletes.

    PubMed

    Diaz-Lara, Francisco Javier; Del Coso, Juan; García, Jose Manuel; Portillo, Luis J; Areces, Francisco; Abián-Vicén, Javier

    2016-11-01

    Scientific information about the effects of caffeine intake on combat sport performance is scarce and controversial. The aim of this study was to investigate the effectiveness of caffeine to improve Brazilian Jiu-jitsu (BJJ)-specific muscular performance. Fourteen male and elite BJJ athletes (29.2 ± 3.3 years; 71.3 ± 9.1 kg) participated in a randomized double-blind, placebo-controlled and crossover experiment. In two different sessions, BJJ athletes ingested 3 mg kg(-1) of caffeine or a placebo. After 60 min, they performed a handgrip maximal force test, a countermovement jump, a maximal static lift test and bench-press tests consisting of one-repetition maximum, power-load, and repetitions to failure. In comparison to the placebo, the ingestion of the caffeine increased: hand grip force in both hands (50.9 ± 2.9 vs. 53.3 ± 3.1 kg; respectively p < .05), countermovement jump height (40.6 ± 2.6 vs. 41.7 ± 3.1 cm; p = .02), and time recorded in the maximal static lift test (54.4 ± 13.4 vs. 59.2 ± 11.9 s; p < .01).The caffeine also increased the one-repetition maximum (90.5 ± 7.7 vs. 93.3 ± 7.5 kg; p = .02), maximal power obtained during the power-load test (750.5 ± 154.7 vs. 826.9 ± 163.7 W; p < .01) and mean power during the bench-press exercise test to failure (280.2 ± 52.5 vs. 312.2 ± 78.3 W; p = .04). In conclusion, the pre-exercise ingestion of 3 mg kg(-1) of caffeine increased dynamic and isometric muscular force, power, and endurance strength in elite BJJ athletes. Thus, caffeine might be an effective ergogenic aid to improve physical performance in BJJ.

  14. Low statistical power in biomedical science: a review of three human research domains.

    PubMed

    Dumas-Mallet, Estelle; Button, Katherine S; Boraud, Thomas; Gonon, Francois; Munafò, Marcus R

    2017-02-01

    Studies with low statistical power increase the likelihood that a statistically significant finding represents a false positive result. We conducted a review of meta-analyses of studies investigating the association of biological, environmental or cognitive parameters with neurological, psychiatric and somatic diseases, excluding treatment studies, in order to estimate the average statistical power across these domains. Taking the effect size indicated by a meta-analysis as the best estimate of the likely true effect size, and assuming a threshold for declaring statistical significance of 5%, we found that approximately 50% of studies have statistical power in the 0-10% or 11-20% range, well below the minimum of 80% that is often considered conventional. Studies with low statistical power appear to be common in the biomedical sciences, at least in the specific subject areas captured by our search strategy. However, we also observe evidence that this depends in part on research methodology, with candidate gene studies showing very low average power and studies using cognitive/behavioural measures showing high average power. This warrants further investigation.

  15. Low statistical power in biomedical science: a review of three human research domains

    PubMed Central

    Dumas-Mallet, Estelle; Button, Katherine S.; Boraud, Thomas; Gonon, Francois

    2017-01-01

    Studies with low statistical power increase the likelihood that a statistically significant finding represents a false positive result. We conducted a review of meta-analyses of studies investigating the association of biological, environmental or cognitive parameters with neurological, psychiatric and somatic diseases, excluding treatment studies, in order to estimate the average statistical power across these domains. Taking the effect size indicated by a meta-analysis as the best estimate of the likely true effect size, and assuming a threshold for declaring statistical significance of 5%, we found that approximately 50% of studies have statistical power in the 0–10% or 11–20% range, well below the minimum of 80% that is often considered conventional. Studies with low statistical power appear to be common in the biomedical sciences, at least in the specific subject areas captured by our search strategy. However, we also observe evidence that this depends in part on research methodology, with candidate gene studies showing very low average power and studies using cognitive/behavioural measures showing high average power. This warrants further investigation. PMID:28386409

  16. Six Sessions of Sprint Interval Training Improves Running Performance in Trained Athletes.

    PubMed

    Koral, Jerome; Oranchuk, Dustin J; Herrera, Roberto; Millet, Guillaume Y

    2018-03-01

    Koral, J, Oranchuk, DJ, Herrera, R, and Millet, GY. Six sessions of sprint interval training improves running performance in trained athletes. J Strength Cond Res 32(3): 617-623, 2018-Sprint interval training (SIT) is gaining popularity with endurance athletes. Various studies have shown that SIT allows for similar or greater endurance, strength, and power performance improvements than traditional endurance training but demands less time and volume. One of the main limitations in SIT research is that most studies were performed in a laboratory using expensive treadmills or ergometers. The aim of this study was to assess the performance effects of a novel short-term and highly accessible training protocol based on maximal shuttle runs in the field (SIT-F). Sixteen (12 male, 4 female) trained trail runners completed a 2-week procedure consisting of 4-7 bouts of 30 seconds at maximal intensity interspersed by 4 minutes of recovery, 3 times a week. Maximal aerobic speed (MAS), time to exhaustion at 90% of MAS before test (Tmax at 90% MAS), and 3,000-m time trial (TT3000m) were evaluated before and after training. Data were analyzed using a paired samples t-test, and Cohen's (d) effect sizes were calculated. Maximal aerobic speed improved by 2.3% (p = 0.01, d = 0.22), whereas peak power (PP) and mean power (MP) increased by 2.4% (p = 0.009, d = 0.33) and 2.8% (p = 0.002, d = 0.41), respectively. TT3000m was 6% shorter (p < 0.001, d = 0.35), whereas Tmax at 90% MAS was 42% longer (p < 0.001, d = 0.74). Sprint interval training in the field significantly improved the 3,000-m run, time to exhaustion, PP, and MP in trained trail runners. Sprint interval training in the field is a time-efficient and cost-free means of improving both endurance and power performance in trained athletes.

  17. Does a bout of strength training affect 2,000 m rowing ergometer performance and rowing-specific maximal power 24 h later?

    PubMed

    Gee, Thomas I; French, Duncan N; Howatson, Glyn; Payton, Stephen J; Berger, Nicolas J; Thompson, Kevin G

    2011-11-01

    Rowers regularly undertake rowing training within 24 h of performing bouts of strength training; however, the effect of this practice has not been investigated. This study evaluated the impact of a bout of high-intensity strength training on 2,000 m rowing ergometer performance and rowing-specific maximal power. Eight highly trained male club rowers performed baseline measures of five separate, static squat jumps (SSJ) and countermovement jumps (CMJ), maximal rowing ergometer power strokes (PS) and a single 2,000 m rowing ergometer test (2,000 m). Subsequently, participants performed a high-intensity strength training session consisting of various multi-joint barbell exercises. The 2,000 m test was repeated at 24 and 48 h post-ST, in addition SSJ, CMJ and PS tests were performed at these time points and also at 2 h post-ST. Muscle soreness, serum creatine kinase (CK) and lactate dehydrogenase (LDH) were assessed pre-ST and 2, 24 and 48 h post-ST. Following the ST, there were significant elevations in muscle soreness (2 and 24 h, P < 0.01), CK (2, 24 and 48 h, P < 0.01), and LDH (2 h, P < 0.05) in comparison to baseline values. There were significant decrements across all time points for SSJ, CMJ and PS, which ranged between 3 and 10% (P < 0.05). However, 2,000 m performance and related measurements of heart rate and blood lactate were not significantly affected by ST. In summary, a bout of high-intensity strength training resulted in symptoms of muscle damage and decrements in rowing-specific maximal power, but this did not affect 2,000 m rowing ergometer performance in highly trained rowers.

  18. Six Sessions of Sprint Interval Training Improves Running Performance in Trained Athletes

    PubMed Central

    Oranchuk, Dustin J.; Herrera, Roberto; Millet, Guillaume Y.

    2018-01-01

    Abstract Koral, J, Oranchuk, DJ, Herrera, R, and Millet, GY. Six sessions of sprint interval training improves running performance in trained athletes. J Strength Cond Res 32(3): 617–623, 2018—Sprint interval training (SIT) is gaining popularity with endurance athletes. Various studies have shown that SIT allows for similar or greater endurance, strength, and power performance improvements than traditional endurance training but demands less time and volume. One of the main limitations in SIT research is that most studies were performed in a laboratory using expensive treadmills or ergometers. The aim of this study was to assess the performance effects of a novel short-term and highly accessible training protocol based on maximal shuttle runs in the field (SIT-F). Sixteen (12 male, 4 female) trained trail runners completed a 2-week procedure consisting of 4–7 bouts of 30 seconds at maximal intensity interspersed by 4 minutes of recovery, 3 times a week. Maximal aerobic speed (MAS), time to exhaustion at 90% of MAS before test (Tmax at 90% MAS), and 3,000-m time trial (TT3000m) were evaluated before and after training. Data were analyzed using a paired samples t-test, and Cohen's (d) effect sizes were calculated. Maximal aerobic speed improved by 2.3% (p = 0.01, d = 0.22), whereas peak power (PP) and mean power (MP) increased by 2.4% (p = 0.009, d = 0.33) and 2.8% (p = 0.002, d = 0.41), respectively. TT3000m was 6% shorter (p < 0.001, d = 0.35), whereas Tmax at 90% MAS was 42% longer (p < 0.001, d = 0.74). Sprint interval training in the field significantly improved the 3,000-m run, time to exhaustion, PP, and MP in trained trail runners. Sprint interval training in the field is a time-efficient and cost-free means of improving both endurance and power performance in trained athletes. PMID:29076961

  19. Toward "Constructing" the Concept of Statistical Power: An Optical Analogy.

    ERIC Educational Resources Information Center

    Rogers, Bruce G.

    This paper presents a visual analogy that may be used by instructors to teach the concept of statistical power in statistical courses. Statistical power is mathematically defined as the probability of rejecting a null hypothesis when that null is false, or, equivalently, the probability of detecting a relationship when it exists. The analogy…

  20. The left ventricle as a mechanical engine: from Leonardo da Vinci to the echocardiographic assessment of peak power output-to-left ventricular mass.

    PubMed

    Dini, Frank L; Guarini, Giacinta; Ballo, Piercarlo; Carluccio, Erberto; Maiello, Maria; Capozza, Paola; Innelli, Pasquale; Rosa, Gian M; Palmiero, Pasquale; Galderisi, Maurizio; Razzolini, Renato; Nodari, Savina

    2013-03-01

    The interpretation of the heart as a mechanical engine dates back to the teachings of Leonardo da Vinci, who was the first to apply the laws of mechanics to the function of the heart. Similar to any mechanical engine, whose performance is proportional to the power generated with respect to weight, the left ventricle can be viewed as a power generator whose performance can be related to left ventricular mass. Stress echocardiography may provide valuable information on the relationship between cardiac performance and recruited left ventricular mass that may be used in distinguishing between adaptive and maladaptive left ventricular remodeling. Peak power output-to-mass, obtained during exercise or pharmacological stress echocardiography, is a measure that reflects the number of watts that are developed by 100 g of left ventricular mass under maximal stimulation. Power output-to-mass may be calculated as left ventricular power output per 100 g of left ventricular mass: 100× left ventricular power output divided by left ventricular mass (W/100 g). A simplified formula to calculate power output-to-mass is as follows: 0.222 × cardiac output (l/min) × mean blood pressure (mmHg)/left ventricular mass (g). When the integrity of myocardial structure is compromised, a mismatch becomes apparent between maximal cardiac power output and left ventricular mass; when this occurs, a reduction of the peak power output-to-mass index is observed.

  1. Power-to-load balancing for asymmetric heave wave energy converters with nonideal power take-off

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tom, Nathan M.; Madhi, Farshad; Yeung, Ronald W.

    The aim of this study is to maximize the power-to-load ratio for asymmetric heave wave energy converters. Linear hydrodynamic theory was used to calculate bounds of the expected time-averaged power (TAP) and corresponding surge-restraining force, pitch-restraining torque, and power take-off (PTO) control force with the assumption of sinusoidal displacement. This paper formulates an optimal control problem to handle an objective function with competing terms in an attempt to maximize power capture while minimizing structural and actuator loads in regular and irregular waves. Penalty weights are placed on the surge-restraining force, pitch-restraining torque, and PTO actuation force, thereby allowing the controlmore » focus to concentrate on either power absorption or load mitigation. The penalty weights are used to control peak structural and actuator loads that were found to curb the additional losses in power absorption associated with a nonideal PTO. Thus, in achieving these goals, a per-unit gain in TAP would not lead to a greater per-unit demand in structural strength, hence yielding a favorable benefit-to-cost ratio. Demonstrative results for 'The Berkeley Wedge' in the form of output TAP, reactive TAP needed to drive WEC motion, and the amplitudes of the surge-restraining force, pitch-restraining torque, and PTO control force are shown.« less

  2. Power-to-load balancing for asymmetric heave wave energy converters with nonideal power take-off

    DOE PAGES

    Tom, Nathan M.; Madhi, Farshad; Yeung, Ronald W.

    2017-12-11

    The aim of this study is to maximize the power-to-load ratio for asymmetric heave wave energy converters. Linear hydrodynamic theory was used to calculate bounds of the expected time-averaged power (TAP) and corresponding surge-restraining force, pitch-restraining torque, and power take-off (PTO) control force with the assumption of sinusoidal displacement. This paper formulates an optimal control problem to handle an objective function with competing terms in an attempt to maximize power capture while minimizing structural and actuator loads in regular and irregular waves. Penalty weights are placed on the surge-restraining force, pitch-restraining torque, and PTO actuation force, thereby allowing the controlmore » focus to concentrate on either power absorption or load mitigation. The penalty weights are used to control peak structural and actuator loads that were found to curb the additional losses in power absorption associated with a nonideal PTO. Thus, in achieving these goals, a per-unit gain in TAP would not lead to a greater per-unit demand in structural strength, hence yielding a favorable benefit-to-cost ratio. Demonstrative results for 'The Berkeley Wedge' in the form of output TAP, reactive TAP needed to drive WEC motion, and the amplitudes of the surge-restraining force, pitch-restraining torque, and PTO control force are shown.« less

  3. Solar powered multipurpose remotely powered aircraft

    NASA Technical Reports Server (NTRS)

    Alexandrou, A. N.; Durgin, W. W.; Cohn, R. F.; Olinger, D. J.; Cody, Charlotte K.; Chan, Agnes; Cheung, Kwok-Hung; Conley, Kristin; Crivelli, Paul M.; Javorski, Christian T.

    1992-01-01

    Increase in energy demands coupled with rapid depletion of natural energy resources have deemed solar energy as an attractive alternative source of power. The focus was to design and construct a solar powered, remotely piloted vehicle to demonstrate the feasibility of solar energy as an effective, alternate source of power. The final design included minimizing the power requirements and maximizing the strength-to-weight and lift-to-drag ratios. Given the design constraints, Surya (the code-name given to the aircraft), is a lightweight aircraft primarily built using composite materials and capable of achieving level flight powered entirely by solar energy.

  4. Physique and Performance of Young Wheelchair Basketball Players in Relation with Classification

    PubMed Central

    Zancanaro, Carlo

    2015-01-01

    The relationships among physical characteristics, performance, and functional ability classification of younger wheelchair basketball players have been barely investigated to date. The purpose of this work was to assess anthropometry, body composition, and performance in sport-specific field tests in a national sample of Italian younger wheelchair basketball players as well as to evaluate the association of these variables with the players’ functional ability classification and game-related statistics. Several anthropometric measurements were obtained for 52 out of 91 eligible players nationwide. Performance was assessed in seven sport-specific field tests (5m sprint, 20m sprint with ball, suicide, maximal pass, pass for accuracy, spot shot and lay-ups) and game-related statistics (free-throw points scored per match, two- and three-point field-goals scored per match, and their sum). Association between variables, and predictivity was assessed by correlation and regression analysis, respectively. Players were grouped into four Classes of increasing functional ability (A-D). One-way ANOVA with Bonferroni’s correction for multiple comparisons was used to assess differences between Classes. Sitting height and functional ability Class especially correlated with performance outcomes, but wheelchair basketball experience and skinfolds did not. Game-related statistics and sport-specific field-test scores all showed significant correlation with each other. Upper arm circumference and/or maximal pass and lay-ups test scores were able to explain 42 to 59% of variance in game-related statistics (P<0.001). A clear difference in performance was only found for functional ability Class A and D. Conclusion: In younger wheelchair basketball players, sitting height positively contributes to performance. The maximal pass and lay-ups test should be carefully considered in younger wheelchair basketball training plans. Functional ability Class reflects to a limited extent the actual differences in performance. PMID:26606681

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tom, Nathan M.; Madhi, Farshad; Yeung, Ronald W.

    The aim of this paper is to maximize the power-to-load ratio of the Berkeley Wedge: a one-degree-of-freedom, asymmetrical, energy-capturing, floating breakwater of high performance that is relatively free of viscosity effects. Linear hydrodynamic theory was used to calculate bounds on the expected time-averaged power (TAP) and corresponding surge restraining force, pitch restraining torque, and power take-off (PTO) control force when assuming that the heave motion of the wave energy converter remains sinusoidal. This particular device was documented to be an almost-perfect absorber if one-degree-of-freedom motion is maintained. The success of such or similar future wave energy converter technologies would requiremore » the development of control strategies that can adapt device performance to maximize energy generation in operational conditions while mitigating hydrodynamic loads in extreme waves to reduce the structural mass and overall cost. This paper formulates the optimal control problem to incorporate metrics that provide a measure of the surge restraining force, pitch restraining torque, and PTO control force. The optimizer must now handle an objective function with competing terms in an attempt to maximize power capture while minimizing structural and actuator loads. A penalty weight is placed on the surge restraining force, pitch restraining torque, and PTO actuation force, thereby allowing the control focus to be placed either on power absorption or load mitigation. Thus, in achieving these goals, a per-unit gain in TAP would not lead to a greater per-unit demand in structural strength, hence yielding a favorable benefit-to-cost ratio. Demonstrative results in the form of TAP, reactive TAP, and the amplitudes of the surge restraining force, pitch restraining torque, and PTO control force are shown for the Berkeley Wedge example.« less

  6. Strength-Power Performance of Visually Impaired Paralympic and Olympic Judo Athletes From the Brazilian National Team: A Comparative Study.

    PubMed

    Loturco, Irineu; Nakamura, Fábio Y; Winckler, Ciro; Bragança, Jaime R; da Fonseca, Roger A; Moraes-Filho, Josué; Zaccani, Wagner A; Kobal, Ronaldo; Cal Abad, Cesar C; Kitamura, Katia; Pereira, Lucas A; Franchini, Emerson

    2017-03-01

    Loturco, I, Nakamura, FY, Winckler, C, Bragança, JR, da Fonseca, RA, Filho, JM, Zaccani, WA, Kobal, R, Cal Abad, CC, Kitamura, K, Pereira, LA, and Franchini, E. Strength-power performance of visually impaired paralympic and olympic judo athletes from the brazilian national team: a comparative study. J Strength Cond Res 31(3): 743-749, 2017-The aim of this study was to compare the muscle power and maximal isometric strength capacities of Olympic and visually impaired Paralympic judo athletes. Twenty-eight elite judo athletes (7 men and 7 women per group) from the permanent Brazilian National Paralympic and Olympic teams took part in this study. After a specific warm-up, the athletes performed loaded jump squat (JS), bench press (BP), and standing barbell row (SBR) exercises to determine their values of maximum mean propulsive power (MPP) in these respective exercises. The maximal isometric strength (MIS) was also determined for both upper and lower limbs, through the use of BP and half-squat (HS) exercises. Finally, the jumping ability was assessed using unloaded squat jump (SJ). The magnitude-based inference was used to compare the groups. The Olympic judo athletes presented a likely higher SJ height than the Paralympic athletes. The Olympic group presented almost certainly higher MPP in the loaded JS and in the SBR exercises and likely higher MPP in the BP exercise. Importantly, in the MIS assessments the differences between groups in the HS and BP exercises were rated as unclear. In conclusion, our results showed that both Olympic and Paralympic judo athletes present similar levels of maximal isometric strength, but muscle power performance is superior in Olympic athletes.

  7. Resistance training status and effectiveness of low frequency resistance training on upper-body strength and power in highly trained soccer players.

    PubMed

    Hertzog, Maxime; Rumpf, Michael Clemens; Hader, Karim

    2017-08-26

    Soccer is classified as a contact/collision sport with many player-to-player duels. Winning these duels, shielding the ball or fending off an opponent requires upper-body strength and power. Therefore this study aimed, a) to examine the time-related effect of an upper-body RT on maximal strength and power changes in highly trained soccer players, b) to investigate if the resistance-training (RT) status influences these changes throughout a competitive season. Twenty-eight soccer players participated in this study and were divided into an untrained (UG) and a trained (TG) group, according to their RT status. Both groups performed the same upper-body RT once a week, over 30 weeks. Maximal strength (1RM) and maximal power (MP) were assessed before, during and after the competitive season. Both groups significantly improved 1RM and MP over the entire competitive season, with a moderate (TG, 13%) to very large (UG, 21%) magnitude in 1RM and with a small (TG, 8%) to moderate (UG, 13%) magnitude in MP. After the initial 10 weeks of RT, UG presented significant and slightly (1RM) to moderately (MP) greater improvements than TG. For all other time intervals, the between-groups changes in 1RM were rated as similar. For the last 20 weeks of the RT, the change in MP was significantly lower for UG compared to TG. One upper-body RT-session per week will provide sufficient stimulus to enable an almost certain improvement in strength and power throughout a competitive season for all players disregarding their initial RT status.

  8. Listing All Maximal Cliques in Sparse Graphs in Near-optimal Time

    DTIC Science & Technology

    2011-01-01

    523 10 Arabisopsis thaliana 1745 3098 71 12 Drosophila melanogaster 7282 24894 176 12 Homo Sapiens 9527 31182 308 12 Schizosaccharomyces pombe 2031...clusters of actors [6,14,28,40] and may be used as features in exponential random graph models for statistical analysis of social networks [17,19,20,44,49...29. R. Horaud and T. Skordas. Stereo correspondence through feature grouping and maximal cliques. IEEE Trans. Patt. An. Mach. Int. 11(11):1168–1180

  9. Phenomenology of maximal and near-maximal lepton mixing

    NASA Astrophysics Data System (ADS)

    Gonzalez-Garcia, M. C.; Peña-Garay, Carlos; Nir, Yosef; Smirnov, Alexei Yu.

    2001-01-01

    The possible existence of maximal or near-maximal lepton mixing constitutes an intriguing challenge for fundamental theories of flavor. We study the phenomenological consequences of maximal and near-maximal mixing of the electron neutrino with other (x=tau and/or muon) neutrinos. We describe the deviations from maximal mixing in terms of a parameter ɛ≡1-2 sin2 θex and quantify the present experimental status for \\|ɛ\\|<0.3. We show that both probabilities and observables depend on ɛ quadratically when effects are due to vacuum oscillations and they depend on ɛ linearly if matter effects dominate. The most important information on νe mixing comes from solar neutrino experiments. We find that the global analysis of solar neutrino data allows maximal mixing with confidence level better than 99% for 10-8 eV2<~Δm2<~2×10-7 eV2. In the mass ranges Δm2>~1.5×10-5 eV2 and 4×10-10 eV2<~Δm2<~2×10-7 eV2 the full interval \\|ɛ\\|<0.3 is allowed within ~4σ (99.995% CL) We suggest ways to measure ɛ in future experiments. The observable that is most sensitive to ɛ is the rate [NC]/[CC] in combination with the day-night asymmetry in the SNO detector. With theoretical and statistical uncertainties, the expected accuracy after 5 years is Δɛ~0.07. We also discuss the effects of maximal and near-maximal νe mixing in atmospheric neutrinos, supernova neutrinos, and neutrinoless double beta decay.

  10. Conformity of modified O-ring test and maximal pinch strength for cross tape application direction.

    PubMed

    Lee, Jung-Hoon; Choi, Hyun-Su

    2018-06-01

    Although cross tape has recently been used by clinicians for various musculoskeletal conditions, scientific studies on the direction of cross tape application are lacking. The present study aimed to investigate whether the direction of cross tape application affected the outcomes of the modified O-ring test and maximal pinch strength using a pinch gauge and the conformity between these 2 tests when cross tape was applied to the forearm muscles of individuals with no upper extremity pain and no restriction of joint range of motion.This study used a single-blinding crossover design. The subjects comprised 39 adults (16 men and 23 women). Cross tape was applied to the dominant hand so that the 4 rows were at an angle of 45° to the right or left of the direction of the flexor digitorum superficialis muscle fibers, and then the subjects underwent a modified O-ring test and a test of maximal pinch strength using a pinch gauge. Both tests were performed in both directions, and the order of the directions and tests was randomized. SPSS 18.0 was used for statistical analysis. Cohen's kappa coefficient was used to analyze the conformity of the results from the 2 tests. The statistical significance level was P < .05. A positive response in the modified O-ring test and maximal pinch strength were both affected by cross tape direction. The modified O-ring test and maximal pinch strength using pinch gauge results were in agreement (P < .00), and the kappa coefficient was significant at 1.00. The direction of cross tape application that produced a positive response in the modified O-ring test also produced greater maximal pinch strength. Thus, we propose that when applying cross tape to muscles, the direction of the 4 lines of the cross tape should be 45° relative to the direction of the muscle fibers, toward the side that produces a positive response in the modified O-ring test or produces the greatest maximal pinch strength using a pinch gauge.

  11. Reconstruction of signals with unknown spectra in information field theory with parameter uncertainty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ensslin, Torsten A.; Frommert, Mona

    2011-05-15

    The optimal reconstruction of cosmic metric perturbations and other signals requires knowledge of their power spectra and other parameters. If these are not known a priori, they have to be measured simultaneously from the same data used for the signal reconstruction. We formulate the general problem of signal inference in the presence of unknown parameters within the framework of information field theory. To solve this, we develop a generic parameter-uncertainty renormalized estimation (PURE) technique. As a concrete application, we address the problem of reconstructing Gaussian signals with unknown power-spectrum with five different approaches: (i) separate maximum-a-posteriori power-spectrum measurement and subsequentmore » reconstruction, (ii) maximum-a-posteriori reconstruction with marginalized power-spectrum, (iii) maximizing the joint posterior of signal and spectrum, (iv) guessing the spectrum from the variance in the Wiener-filter map, and (v) renormalization flow analysis of the field-theoretical problem providing the PURE filter. In all cases, the reconstruction can be described or approximated as Wiener-filter operations with assumed signal spectra derived from the data according to the same recipe, but with differing coefficients. All of these filters, except the renormalized one, exhibit a perception threshold in case of a Jeffreys prior for the unknown spectrum. Data modes with variance below this threshold do not affect the signal reconstruction at all. Filter (iv) seems to be similar to the so-called Karhune-Loeve and Feldman-Kaiser-Peacock estimators for galaxy power spectra used in cosmology, which therefore should also exhibit a marginal perception threshold if correctly implemented. We present statistical performance tests and show that the PURE filter is superior to the others, especially if the post-Wiener-filter corrections are included or in case an additional scale-independent spectral smoothness prior can be adopted.« less

  12. Bi-Level Arbitrage Potential Evaluation for Grid-Scale Energy Storage Considering Wind Power and LMP Smoothing Effect

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cui, Hantao; Li, Fangxing; Fang, Xin

    Our paper deals with extended-term energy storage (ES) arbitrage problems to maximize the annual revenue in deregulated power systems with high penetration wind power. The conventional ES arbitrage model takes the locational marginal prices (LMP) as an input and is unable to account for the impacts of ES operations on system LMPs. This paper proposes a bi-level ES arbitrage model, where the upper level maximizes the ES arbitrage revenue and the lower level simulates the market clearing process considering wind power and ES. The bi-level model is formulated as a mathematical program with equilibrium constraints (MPEC) and then recast intomore » a mixed-integer linear programming (MILP) using strong duality theory. Wind power fluctuations are characterized by the GARCH forecast model and the forecast error is modeled by forecast-bin based Beta distributions. Case studies are performed on a modified PJM 5-bus system and an IEEE 118-bus system with a weekly time horizon over an annual term to show the validity of the proposed bi-level model. The results from the conventional model and the bi-level model are compared under different ES power and energy ratings, and also various load and wind penetration levels.« less

  13. Energy-harvesting at the Nanoscale

    NASA Astrophysics Data System (ADS)

    Jordan, Andrew; Sothmann, Björn; Sánchez, Rafael; Büttiker, Markus

    2013-03-01

    Energy harvesting is the process by which energy is taken from the environment and transformed to provide power for electronics. Specifically, the conversion of thermal energy into electrical power, or thermoelectrics, can play a crucial role in future developments of alternative sources of energy. Unfortunately, present thermoelectrics have low efficiency. Therefore, an important task in condensed matter physics is to find new ways to harvest ambient thermal energy, particularly at the smallest length scales where electronics operate. To achieve this goal, there is on one hand the miniaturizing of electrical devices, and on the other, the maximization of either efficiency or power the devices produce. We will present the theory of nano heat engines able to efficiently convert heat into electrical power. We propose a resonant tunneling quantum dot engine that can be operated either in the Carnot efficient mode, or maximal power mode. The ability to scale the power by putting many such engines in a ``Swiss cheese sandwich'' geometry gives a paradigmatic system for harvesting thermal energy at the nanoscale. This work was supported by the US NSF Grant No. DMR-0844899, the Swiss NSF, the NCCR MaNEP and QSIT, the European STREP project Nanopower, the CSIC and FSE JAE-Doc program, the Spanish MAT2011-24331 and the ITN Grant 234970 (EU)

  14. Bi-Level Arbitrage Potential Evaluation for Grid-Scale Energy Storage Considering Wind Power and LMP Smoothing Effect

    DOE PAGES

    Cui, Hantao; Li, Fangxing; Fang, Xin; ...

    2017-10-04

    Our paper deals with extended-term energy storage (ES) arbitrage problems to maximize the annual revenue in deregulated power systems with high penetration wind power. The conventional ES arbitrage model takes the locational marginal prices (LMP) as an input and is unable to account for the impacts of ES operations on system LMPs. This paper proposes a bi-level ES arbitrage model, where the upper level maximizes the ES arbitrage revenue and the lower level simulates the market clearing process considering wind power and ES. The bi-level model is formulated as a mathematical program with equilibrium constraints (MPEC) and then recast intomore » a mixed-integer linear programming (MILP) using strong duality theory. Wind power fluctuations are characterized by the GARCH forecast model and the forecast error is modeled by forecast-bin based Beta distributions. Case studies are performed on a modified PJM 5-bus system and an IEEE 118-bus system with a weekly time horizon over an annual term to show the validity of the proposed bi-level model. The results from the conventional model and the bi-level model are compared under different ES power and energy ratings, and also various load and wind penetration levels.« less

  15. Letter to the editor concerning the article "Bar velocities capable of optimising the muscle power in strength-power exercises" by Loturco, Pereira, Abad, Tabares, Moraes, Kobal, Kitamura & Nakamura (2017).

    PubMed

    Jaric, Slobodan; Garcia Ramos, Amador

    2018-05-01

    Loturco and co-workers (2017) recently published data in the Journal of Sports Sciences to present the optimum loading magnitudes regarding the maximization of the "mean propulsive power" of the leg and arm muscles. Among the most important findings were that (1) the recorded power in the squat and squat jump exercises was markedly low, (2) the optimum external load that maximized the power in the same exercises was close to 100% of body weight, while (3) the ballistic bench press throw revealed smaller power than the regular bench press typically performed with relatively low level of muscle activation towards the end of the propulsive lifting phase. The findings are either counter-intuitive, or contradict the literature findings, or both, and we believe that they originate from apparent methodological flaws. The first one is neglecting the force acting against the body segments moved together with the external load that is particularly high in squat exercises. The second one is an erroneous calculation of the propulsive phase that included a part of the bar's flight time. Both of these methodological flaws are frequent in the literature and could be associated with the improper use and calculation of variables when utilizing linear position transducers.

  16. Preference option randomized design (PORD) for comparative effectiveness research: Statistical power for testing comparative effect, preference effect, selection effect, intent-to-treat effect, and overall effect.

    PubMed

    Heo, Moonseong; Meissner, Paul; Litwin, Alain H; Arnsten, Julia H; McKee, M Diane; Karasz, Alison; McKinley, Paula; Rehm, Colin D; Chambers, Earle C; Yeh, Ming-Chin; Wylie-Rosett, Judith

    2017-01-01

    Comparative effectiveness research trials in real-world settings may require participants to choose between preferred intervention options. A randomized clinical trial with parallel experimental and control arms is straightforward and regarded as a gold standard design, but by design it forces and anticipates the participants to comply with a randomly assigned intervention regardless of their preference. Therefore, the randomized clinical trial may impose impractical limitations when planning comparative effectiveness research trials. To accommodate participants' preference if they are expressed, and to maintain randomization, we propose an alternative design that allows participants' preference after randomization, which we call a "preference option randomized design (PORD)". In contrast to other preference designs, which ask whether or not participants consent to the assigned intervention after randomization, the crucial feature of preference option randomized design is its unique informed consent process before randomization. Specifically, the preference option randomized design consent process informs participants that they can opt out and switch to the other intervention only if after randomization they actively express the desire to do so. Participants who do not independently express explicit alternate preference or assent to the randomly assigned intervention are considered to not have an alternate preference. In sum, preference option randomized design intends to maximize retention, minimize possibility of forced assignment for any participants, and to maintain randomization by allowing participants with no or equal preference to represent random assignments. This design scheme enables to define five effects that are interconnected with each other through common design parameters-comparative, preference, selection, intent-to-treat, and overall/as-treated-to collectively guide decision making between interventions. Statistical power functions for testing all these effects are derived, and simulations verified the validity of the power functions under normal and binomial distributions.

  17. Community standards for genomic resources, genetic conservation, and data integration

    Treesearch

    Jill Wegrzyn; Meg Staton; Emily Grau; Richard Cronn; C. Dana Nelson

    2017-01-01

    Genetics and genomics are increasingly important in forestry management and conservation. Next generation sequencing can increase analytical power, but still relies on building on the structure of previously acquired data. Data standards and data sharing allow the community to maximize the analytical power of high throughput genomics data. The landscape of incomplete...

  18. Coalition Building: Cultivating New Partners for Physical Education

    ERIC Educational Resources Information Center

    Curva, Fely; Mosteller, James

    2010-01-01

    A coalition is about building power to accomplish change that no one group can reasonably accomplish on its own. A well-defined coalition not only builds power and influence, it broadens support, maximizes resources (e.g., time, money, people and connections), enhances legitimacy, creates synergy, and offers diverse perspectives on issues.…

  19. Design of a Telescopic Linear Actuator Based on Hollow Shape Memory Springs

    NASA Astrophysics Data System (ADS)

    Spaggiari, Andrea; Spinella, Igor; Dragoni, Eugenio

    2011-07-01

    Shape memory alloys (SMAs) are smart materials exploited in many applications to build actuators with high power to mass ratio. Typical SMA drawbacks are: wires show poor stroke and excessive length, helical springs have limited mechanical bandwidth and high power consumption. This study is focused on the design of a large-scale linear SMA actuator conceived to maximize the stroke while limiting the overall size and the electric consumption. This result is achieved by adopting for the actuator a telescopic multi-stage architecture and using SMA helical springs with hollow cross section to power the stages. The hollow geometry leads to reduced axial size and mass of the actuator and to enhanced working frequency while the telescopic design confers to the actuator an indexable motion, with a number of different displacements being achieved through simple on-off control strategies. An analytical thermo-electro-mechanical model is developed to optimize the device. Output stroke and force are maximized while total size and power consumption are simultaneously minimized. Finally, the optimized actuator, showing good performance from all these points of view, is designed in detail.

  20. Maximal aerobic power in cycle ergometry in middle-aged men and women, active in sports, in relation to age and physical activity.

    PubMed

    Bovens, A M; van Baak, M A; Vrencken, J G; Wijnen, J A; Saris, W H; Verstappen, F T

    1993-02-01

    Reliable standards of maximal power output in middle-aged and physically active men and women are desirable in sports-medical practice. For this purpose maximal cycle ergometer tests were evaluated in 2038 men and 898 women over 40 years of age (46.8 +/- 6.1 years (mean +/- SD) and 47.5 +/- 6.6 years), who volunteered in a sports-medical check-up and all of whom were active in sports for at least three months in the year preceding the screening (4.3 +/- 3.1 hours/week respectively 3.6 +/- 2.5 hours/week). The range of maximal values for power output (Wmax), heart rate (HRmax), systolic blood pressure (SBPmax) and peak plasma lactate concentrations (PPLa) during progressive cycle ergometer testing are presented for males and females who were divided into groups with a 5-years age difference. Wmax varied with sex (male = 1, female = 0), age (year) and height (cm); Wmax = 65.3 x (sex) + 2.0 x (height) -1.9 x (age) - 67.9 (See = 38.2; r = 0.76). The weighing of different factors that influence performance was also studied by multiple regression analysis to provide improved precision in standards used to interpret exercise tests. In both men and women about half of the variation of Wmax could be explained by the independent variables age, body mass, body fat, smoking habits, vital capacity, heart rate, and physical activity parameters. It is concluded that active involvement in endurance sports and/or the use of the bicycle for transport, contributed substantially to cardiovascular fitness in healthy, middle-aged men and women.

  1. Effects of pretension on work and power output of the muscle-tendon complex in dynamic elbow flexion.

    PubMed

    Wakayama, Akinobu; Nagano, Akinori; Hay, Dean; Fukashiro, Senshi

    2005-06-01

    The purpose of the present study was to investigate the effects of pretension on work and power output of the muscle-tendon complex during dynamic elbow flexion under several submaximal and maximal conditions. The subjects were 10 healthy female students. Randomized trials from 0% to 100% maximal voluntary contraction (MVC) pretension (PT) at 60 degrees elbow flexion were conducted. After about 3 s of static PT, subjects maximally flexed the elbow joint to 90 degrees using a quick release method. The weight was individually selected for each subject to provide an optimal load for the development of maximal power. A Hill-type model was utilized to analyze the performance of the elbow muscle-tendon complex (MTC). PT 0, 30, 60 and 90% MVC data were used for comparison, and all data were expressed as the mean and standard deviation. Multiple paired comparisons between the value of PT 0% MVC and that of the other PT levels were performed post-hoc using Dunnett's method. The work of the series elastic component (SEC) increased gradually with the PT level because elastic energy was stored in the PT phase. However, the work of the contractile component (CC) decreased gradually with an increase in PT level. Moreover, the work of the MTC also decreased, closely related to the CC work decrement. The phenomenon of CC work decrement was caused by force depression and was not related to either the force-length or force-velocity relationships of the CC. EMG activity (agonist and antagonist) showed no significant differences. Muscle geometry changes or intracellular chemical shifts may have occurred in the PT phase.

  2. Effects of Endurance Training at the Crossover Point in Women with Metabolic Syndrome.

    PubMed

    Borel, Benoit; Coquart, Jérémy; Boitel, Guillaume; Duhamel, Alain; Matran, Régis; Delsart, Pascal; Mounier-Vehier, Claire; Garcin, Murielle

    2015-11-01

    On the basis of theoretical evidence, intensity at the crossover point (COP) of substrate utilization could be considered as potential exercise intensity for metabolic syndrome (MetS). This study aimed to examine the effects of a training program at COP on exercise capacity parameters in women with MetS and to compare two metabolic indices (COP and the maximal fat oxidation rate point LIPOXmax®) with ventilatory threshold (VT). Nineteen women with MetS volunteered to perform a 12-wk training program on a cycle ergometer, with intensity corresponding to COP. Pre- and posttraining values of anthropometric and exercise capacity parameters were compared to determine the effects of exercise training. The pre-post training change of COP, LIPOXmax®, and VT were also investigated. After training, anthropometric parameters were significantly modified, with reduction of body mass (3.0% ± 3.0%, P < 0.001), fat mass (3.3% ± 3.4%, P < 0.001), and body mass index (3.2% ± 3.4%, P < 0.001). Exercise capacity was improved after the training program, with significant increase of maximal power output (25.0% ± 18.4%, P < 0.001) and maximal oxygen uptake (V˙O2max, 9.0% ± 11.2%; P < 0.01). Lastly, when expressed in terms of power output, COP, LIPOXmax®, and VT occurred at a similar exercise intensity, but the occurrence of these three indices is different when expressed in terms of oxygen uptake, HR, or RPE. This study highlights the effectiveness of a 12-wk training program at COP to improve physical fitness in women with MetS. The relations between metabolic indices and VT in terms of power output highlight the determination of VT from a shorter maximal exercise as a useful method for determining metabolic indices in MetS.

  3. Causality in Statistical Power: Isomorphic Properties of Measurement, Research Design, Effect Size, and Sample Size.

    PubMed

    Heidel, R Eric

    2016-01-01

    Statistical power is the ability to detect a significant effect, given that the effect actually exists in a population. Like most statistical concepts, statistical power tends to induce cognitive dissonance in hepatology researchers. However, planning for statistical power by an a priori sample size calculation is of paramount importance when designing a research study. There are five specific empirical components that make up an a priori sample size calculation: the scale of measurement of the outcome, the research design, the magnitude of the effect size, the variance of the effect size, and the sample size. A framework grounded in the phenomenon of isomorphism, or interdependencies amongst different constructs with similar forms, will be presented to understand the isomorphic effects of decisions made on each of the five aforementioned components of statistical power.

  4. Use of an untuned cavity for absolute power measurements of the harmonics above 100 GHz from an IMPATT oscillator

    NASA Astrophysics Data System (ADS)

    Llewellyn-Jones, D. T.; Knight, R. J.; Gebbie, H. A.

    1980-07-01

    A new technique of measuring absolute power exploiting an untuned cavity and Fourier spectroscopy has been used to examine the power spectrum of the harmonics and other overtones produced by a 95 GHz IMPATT oscillator. The conditions which favor the production of a rich harmonic spectrum are not those which maximize the fundamental power. Under some conditions of mismatch at the fundamental frequency it is possible to produce over 200 microW of harmonic power in the 100-200 GHz region comparable with the fundamental power from the oscillator.

  5. Adaptations in athletic performance after ballistic power versus strength training.

    PubMed

    Cormie, Prue; McGuigan, Michael R; Newton, Robert U

    2010-08-01

    To determine whether the magnitude of improvement in athletic performance and the mechanisms driving these adaptations differ in relatively weak individuals exposed to either ballistic power training or heavy strength training. Relatively weak men (n = 24) who could perform the back squat with proficient technique were randomized into three groups: strength training (n = 8; ST), power training (n = 8; PT), or control (n = 8). Training involved three sessions per week for 10 wk in which subjects performed back squats with 75%-90% of one-repetition maximum (1RM; ST) or maximal-effort jump squats with 0%-30% 1RM (PT). Jump and sprint performances were assessed as well as measures of the force-velocity relationship, jumping mechanics, muscle architecture, and neural drive. Both experimental groups showed significant (P < or = 0.05) improvements in jump and sprint performances after training with no significant between-group differences evident in either jump (peak power: ST = 17.7% +/- 9.3%, PT = 17.6% +/- 4.5%) or sprint performance (40-m sprint: ST = 2.2% +/- 1.9%, PT = 3.6% +/- 2.3%). ST also displayed a significant increase in maximal strength that was significantly greater than the PT group (squat 1RM: ST = 31.2% +/- 11.3%, PT = 4.5% +/- 7.1%). The mechanisms driving these improvements included significant (P < or = 0.05) changes in the force-velocity relationship, jump mechanics, muscle architecture, and neural activation that showed a degree of specificity to the different training stimuli. Improvements in athletic performance were similar in relatively weak individuals exposed to either ballistic power training or heavy strength training for 10 wk. These performance improvements were mediated through neuromuscular adaptations specific to the training stimulus. The ability of strength training to render similar short-term improvements in athletic performance as ballistic power training, coupled with the potential long-term benefits of improved maximal strength, makes strength training a more effective training modality for relatively weak individuals.

  6. The Statistical Power of Planned Comparisons.

    ERIC Educational Resources Information Center

    Benton, Roberta L.

    Basic principles underlying statistical power are examined; and issues pertaining to effect size, sample size, error variance, and significance level are highlighted via the use of specific hypothetical examples. Analysis of variance (ANOVA) and related methods remain popular, although other procedures sometimes have more statistical power against…

  7. Steve Frank | NREL

    Science.gov Websites

    Commercial Buildings Research Group. Steve's areas of expertise are electric power distribution systems, DC techniques for maximizing the energy efficiency of electrical distribution systems in commercial buildings

  8. [Optimal versus maximal safety of the blood transfusion chain in The Netherlands; results of a conference. College for Blood Transfusion of the Dutch Red Cross].

    PubMed

    van der Poel, C L; de Boer, J E; Reesink, H W; Sibinga, C T

    1998-02-07

    An invitational conference was held on September 11, 1996 by the Medical Advisory Commission to the Blood Transfusion Council of the Netherlands Red Cross, addressing the issues of 'maximal' versus 'optimal' safety measures for the blood supply. Invited were blood transfusion specialists, clinicians, representatives of patient interest groups, the Ministry and Inspectorate of Health and members of parliament. Transfusion experts and clinicians were found to advocate an optimal course, following strategies of evidence-based medicine, cost-benefit analyses and medical technology assessment. Patient groups depending on blood products, such as haemophilia patients would rather opt for maximal safety. Insurance companies would choose likewise, to exclude any risk if possible. Health care juridical advisers would advise to choose for optimal safety, but to reserve funds covering the differences with 'maximal safety' in case of litigation. Politicians and the general public would sooner choose for maximal rather than optimal security. The overall impression persists that however small the statistical risk may be, in the eyes of many it is unacceptable. This view is very stubborn.

  9. Correlation between urodynamic function and 3D cat scan anatomy in neobladders: does it exist?

    PubMed

    Crivellaro, S; Mami, E; Wald, C; Smith, J J; Kocjancic, E; Stoffel, J; Bresette, J; Libertino, J A

    2009-01-01

    We compared the functional and anatomical differences among three different orthotopic neobladders, utilizing video urodynamics and 3D CT to determine what parameters, if any, correlate to function. Thirty-four patients were able to participate in the evaluation of their neobladder by 3D CT and video urodynamics. Three different orthotopic neobladders were identified (12 ileal, 7 ileocecal, 15 sigmoid). Multiple measurements, observations and functional data have been obtained. Statistical analysis for this study employed a linear regression test and an odds ratio calculation (using StatSoft V. 5.1). In comparing three different neobladders, no significant differences were noted. Looking at the entire population, the following association was statistically significant in linear correlation: the maximal capacity and the neobladder volume; the pressure at the maximal capacity and the distance from the symphysis, the pressure at maximal flow and both the distance from the symphysis and the thickness of the neobladder. The distance from the left femoral head was directly correlated with the post void residual and inversely correlated with the maximal flow. The Odds ratio calculation revealed (with significant P < 0.05) that the further the center of the neobladder is from the right femoral head, the higher risk of incontinence. The study seems to show no significant anatomical or functional difference among the three different types of neobladders. A possible correlation between the position of the neobladder and urinary incontinence is suggested, recognizing further study in a larger population is required.

  10. A study comparing precision of the maximum multipoint heterogeneity LOD statistic to three model-free multipoint linkage methods.

    PubMed

    Finch, S J; Chen, C H; Gordon, D; Mendell, N R

    2001-12-01

    This study compared the performance of the maximum lod (MLOD), maximum heterogeneity lod (MHLOD), maximum non-parametric linkage score (MNPL), maximum Kong and Cox linear extension (MKC(lin)) of NPL, and maximum Kong and Cox exponential extension (MKC(exp)) of NPL as calculated in Genehunter 1.2 and Genehunter-Plus. Our performance measure was the distance between the marker with maximum value for each linkage statistic and the trait locus. We performed a simulation study considering: 1) four modes of transmission, 2) 100 replicates for each model, 3) 58 pedigrees (with 592 subjects) per replicate, 4) three linked marker loci each having three equally frequent alleles, and 5) either 0% unlinked families (linkage homogeneity) or 50% unlinked families (linkage heterogeneity). For each replicate, we obtained the Haldane map position of the location at which each of the five statistics is maximized. The MLOD and MHLOD were obtained by maximizing over penetrances, phenocopy rate, and risk-allele frequencies. For the models simulated, MHLOD appeared to be the best statistic both in terms of identifying a marker locus having the smallest mean distance from the trait locus and in terms of the strongest negative correlation between maximum linkage statistic and distance of the identified position and the trait locus. The marker loci with maximum value of the Kong and Cox extensions of the NPL statistic also were closer to the trait locus than the marker locus with maximum value of the NPL statistic. Copyright 2001 Wiley-Liss, Inc.

  11. Letting the daylight in: Reviewing the reviewers and other ways to maximize transparency in science

    PubMed Central

    Wicherts, Jelte M.; Kievit, Rogier A.; Bakker, Marjan; Borsboom, Denny

    2012-01-01

    With the emergence of online publishing, opportunities to maximize transparency of scientific research have grown considerably. However, these possibilities are still only marginally used. We argue for the implementation of (1) peer-reviewed peer review, (2) transparent editorial hierarchies, and (3) online data publication. First, peer-reviewed peer review entails a community-wide review system in which reviews are published online and rated by peers. This ensures accountability of reviewers, thereby increasing academic quality of reviews. Second, reviewers who write many highly regarded reviews may move to higher editorial positions. Third, online publication of data ensures the possibility of independent verification of inferential claims in published papers. This counters statistical errors and overly positive reporting of statistical results. We illustrate the benefits of these strategies by discussing an example in which the classical publication system has gone awry, namely controversial IQ research. We argue that this case would have likely been avoided using more transparent publication practices. We argue that the proposed system leads to better reviews, meritocratic editorial hierarchies, and a higher degree of replicability of statistical analyses. PMID:22536180

  12. Research Designs for Intervention Research with Small Samples II: Stepped Wedge and Interrupted Time-Series Designs.

    PubMed

    Fok, Carlotta Ching Ting; Henry, David; Allen, James

    2015-10-01

    The stepped wedge design (SWD) and the interrupted time-series design (ITSD) are two alternative research designs that maximize efficiency and statistical power with small samples when contrasted to the operating characteristics of conventional randomized controlled trials (RCT). This paper provides an overview and introduction to previous work with these designs and compares and contrasts them with the dynamic wait-list design (DWLD) and the regression point displacement design (RPDD), which were presented in a previous article (Wyman, Henry, Knoblauch, and Brown, Prevention Science. 2015) in this special section. The SWD and the DWLD are similar in that both are intervention implementation roll-out designs. We discuss similarities and differences between the SWD and DWLD in their historical origin and application, along with differences in the statistical modeling of each design. Next, we describe the main design characteristics of the ITSD, along with some of its strengths and limitations. We provide a critical comparative review of strengths and weaknesses in application of the ITSD, SWD, DWLD, and RPDD as small sample alternatives to application of the RCT, concluding with a discussion of the types of contextual factors that influence selection of an optimal research design by prevention researchers working with small samples.

  13. Research Designs for Intervention Research with Small Samples II: Stepped Wedge and Interrupted Time-Series Designs

    PubMed Central

    Ting Fok, Carlotta Ching; Henry, David; Allen, James

    2015-01-01

    The stepped wedge design (SWD) and the interrupted time-series design (ITSD) are two alternative research designs that maximize efficiency and statistical power with small samples when contrasted to the operating characteristics of conventional randomized controlled trials (RCT). This paper provides an overview and introduction to previous work with these designs, and compares and contrasts them with the dynamic wait-list design (DWLD) and the regression point displacement design (RPDD), which were presented in a previous article (Wyman, Henry, Knoblauch, and Brown, 2015) in this Special Section. The SWD and the DWLD are similar in that both are intervention implementation roll-out designs. We discuss similarities and differences between the SWD and DWLD in their historical origin and application, along with differences in the statistical modeling of each design. Next, we describe the main design characteristics of the ITSD, along with some of its strengths and limitations. We provide a critical comparative review of strengths and weaknesses in application of the ITSD, SWD, DWLD, and RPDD as small samples alternatives to application of the RCT, concluding with a discussion of the types of contextual factors that influence selection of an optimal research design by prevention researchers working with small samples. PMID:26017633

  14. The predictive power of zero intelligence in financial markets.

    PubMed

    Farmer, J Doyne; Patelli, Paolo; Zovko, Ilija I

    2005-02-08

    Standard models in economics stress the role of intelligent agents who maximize utility. However, there may be situations where constraints imposed by market institutions dominate strategic agent behavior. We use data from the London Stock Exchange to test a simple model in which minimally intelligent agents place orders to trade at random. The model treats the statistical mechanics of order placement, price formation, and the accumulation of revealed supply and demand within the context of the continuous double auction and yields simple laws relating order-arrival rates to statistical properties of the market. We test the validity of these laws in explaining cross-sectional variation for 11 stocks. The model explains 96% of the variance of the gap between the best buying and selling prices (the spread) and 76% of the variance of the price diffusion rate, with only one free parameter. We also study the market impact function, describing the response of quoted prices to the arrival of new orders. The nondimensional coordinates dictated by the model approximately collapse data from different stocks onto a single curve. This work is important from a practical point of view, because it demonstrates the existence of simple laws relating prices to order flows and, in a broader context, suggests there are circumstances where the strategic behavior of agents may be dominated by other considerations.

  15. DHLAS: A web-based information system for statistical genetic analysis of HLA population data.

    PubMed

    Thriskos, P; Zintzaras, E; Germenis, A

    2007-03-01

    DHLAS (database HLA system) is a user-friendly, web-based information system for the analysis of human leukocyte antigens (HLA) data from population studies. DHLAS has been developed using JAVA and the R system, it runs on a Java Virtual Machine and its user-interface is web-based powered by the servlet engine TOMCAT. It utilizes STRUTS, a Model-View-Controller framework and uses several GNU packages to perform several of its tasks. The database engine it relies upon for fast access is MySQL, but others can be used a well. The system estimates metrics, performs statistical testing and produces graphs required for HLA population studies: (i) Hardy-Weinberg equilibrium (calculated using both asymptotic and exact tests), (ii) genetics distances (Euclidian or Nei), (iii) phylogenetic trees using the unweighted pair group method with averages and neigbor-joining method, (iv) linkage disequilibrium (pairwise and overall, including variance estimations), (v) haplotype frequencies (estimate using the expectation-maximization algorithm) and (vi) discriminant analysis. The main merit of DHLAS is the incorporation of a database, thus, the data can be stored and manipulated along with integrated genetic data analysis procedures. In addition, it has an open architecture allowing the inclusion of other functions and procedures.

  16. Labor costs incurred by anesthesiology groups because of operating rooms not being allocated and cases not being scheduled to maximize operating room efficiency.

    PubMed

    Abouleish, Amr E; Dexter, Franklin; Epstein, Richard H; Lubarsky, David A; Whitten, Charles W; Prough, Donald S

    2003-04-01

    Determination of operating room (OR) block allocation and case scheduling is often not based on maximizing OR efficiency, but rather on tradition and surgeon convenience. As a result, anesthesiology groups often incur additional labor costs. When negotiating financial support, heads of anesthesiology departments are often challenged to justify the subsidy necessary to offset these additional labor costs. In this study, we describe a method for calculating a statistically sound estimate of the excess labor costs incurred by an anesthesiology group because of inefficient OR allocation and case scheduling. OR information system and anesthesia staffing data for 1 yr were obtained from two university hospitals. Optimal OR allocation for each surgical service was determined by maximizing the efficiency of use of the OR staff. Hourly costs were converted to dollar amounts by using the nationwide median compensation for academic and private-practice anesthesia providers. Differences between actual costs and the optimal OR allocation were determined. For Hospital A, estimated annual excess labor costs were $1.6 million (95% confidence interval, $1.5-$1.7 million) and $2.0 million ($1.89-$2.05 million) when academic and private-practice compensation, respectively, was calculated. For Hospital B, excess labor costs were $1.0 million ($1.08-$1.17 million) and $1.4 million ($1.32-1.43 million) for academic and private-practice compensation, respectively. This study demonstrates a methodology for an anesthesiology group to estimate its excess labor costs. The group can then use these estimates when negotiating for subsidies with its hospital, medical school, or multispecialty medical group. We describe a new application for a previously reported statistical method to calculate operating room (OR) allocations to maximize OR efficiency. When optimal OR allocations and case scheduling are not implemented, the resulting increase in labor costs can be used in negotiations as a statistically sound estimate for the increased labor cost to the anesthesiology department.

  17. The Response to and Recovery From Maximum-Strength and -Power Training in Elite Track and Field Athletes.

    PubMed

    Howatson, Glyn; Brandon, Raphael; Hunter, Angus M

    2016-04-01

    There is a great deal of research on the responses to resistance training; however, information on the responses to strength and power training conducted by elite strength and power athletes is sparse. To establish the acute and 24-h neuromuscular and kinematic responses to Olympic-style barbell strength and power exercise in elite athletes. Ten elite track and field athletes completed a series of 3 back-squat exercises each consisting of 4 × 5 repetitions. These were done as either strength or power sessions on separate days. Surface electromyography (sEMG), bar velocity, and knee angle were monitored throughout these exercises and maximal voluntary contraction (MVC), jump height, central activation ratio (CAR), and lactate were measured pre, post, and 24 h thereafter. Repetition duration, impulse, and total work were greater (P < .01) during strength sessions, with mean power being greater (P < .01) after the power sessions. Lactate increased (P < .01) after strength but not power sessions. sEMG increased (P < .01) across sets for both sessions, with the strength session increasing at a faster rate (P < .01) and with greater activation (P < .01) by the end of the final set. MVC declined (P < .01) after the strength and not the power session, which remained suppressed (P < .05) 24 h later, whereas CAR and jump height remained unchanged. A greater neuromuscular and metabolic demand after the strength and not power session is evident in elite athletes, which impaired maximal-force production for up to 24 h. This is an important consideration for planning concurrent athlete training.

  18. Short-Term High Intensity Plyometric Training Program Improves Strength, Power and Agility in Male Soccer Players

    PubMed Central

    Váczi, Márk; Tollár, József; Meszler, Balázs; Juhász, Ivett; Karsai, István

    2013-01-01

    The aim of the present study was to investigate the effects of a short-term in-season plyometric training program on power, agility and knee extensor strength. Male soccer players from a third league team were assigned into an experimental and a control group. The experimental group, beside its regular soccer training sessions, performed a periodized plyometric training program for six weeks. The program included two training sessions per week, and maximal intensity unilateral and bilateral plyometric exercises (total of 40 – 100 foot contacts/session) were executed. Controls participated only in the same soccer training routine, and did not perform plyometrics. Depth vertical jump height, agility (Illinois Agility Test, T Agility Test) and maximal voluntary isometric torque in knee extensors using Multicont II dynamometer were evaluated before and after the experiment. In the experimental group small but significant improvements were found in both agility tests, while depth jump height and isometric torque increments were greater. The control group did not improve in any of the measures. Results of the study indicate that plyometric training consisting of high impact unilateral and bilateral exercises induced remarkable improvements in lower extremity power and maximal knee extensor strength, and smaller improvements in soccer-specific agility. Therefore, it is concluded that short-term plyometric training should be incorporated in the in-season preparation of lower level players to improve specific performance in soccer. PMID:23717351

  19. Short-term high intensity plyometric training program improves strength, power and agility in male soccer players.

    PubMed

    Váczi, Márk; Tollár, József; Meszler, Balázs; Juhász, Ivett; Karsai, István

    2013-03-01

    The aim of the present study was to investigate the effects of a short-term in-season plyometric training program on power, agility and knee extensor strength. Male soccer players from a third league team were assigned into an experimental and a control group. The experimental group, beside its regular soccer training sessions, performed a periodized plyometric training program for six weeks. The program included two training sessions per week, and maximal intensity unilateral and bilateral plyometric exercises (total of 40 - 100 foot contacts/session) were executed. Controls participated only in the same soccer training routine, and did not perform plyometrics. Depth vertical jump height, agility (Illinois Agility Test, T Agility Test) and maximal voluntary isometric torque in knee extensors using Multicont II dynamometer were evaluated before and after the experiment. In the experimental group small but significant improvements were found in both agility tests, while depth jump height and isometric torque increments were greater. The control group did not improve in any of the measures. Results of the study indicate that plyometric training consisting of high impact unilateral and bilateral exercises induced remarkable improvements in lower extremity power and maximal knee extensor strength, and smaller improvements in soccer-specific agility. Therefore, it is concluded that short-term plyometric training should be incorporated in the in-season preparation of lower level players to improve specific performance in soccer.

  20. Multi-objective optimal control of vibratory energy harvesting systems

    NASA Astrophysics Data System (ADS)

    Scruggs, J. T.

    2008-03-01

    This paper presents a new approach, based on H II optimal control theory, for the maximization of power generation in energy harvesting systems. The theory determines the optimal harvested power attainable through the use of power electronics to effect linear feedback control of transducer current. In contrast to most of the prior work in this area, which has assumed harmonic response, the theory proposed here applies to stochastically-excited systems in broadband response, and can be used to harvest power simultaneously from multiple significant vibratory modes. It is also applicable to coupled networks of many transducers. The theory accounts for the impact of energy harvesting on the dynamics of the vibrating system in which the transducers are embedded. It also accounts for resistive and semiconductor dissipation in the power-electronic network interfacing the transducers with energy storage. Thus, losses in the electronics are addressed in the formulation of the optimal control law. Finally, the H II-optimal control formulation of the problem naturally allows for harvested power to be systematically balanced against other response objectives. Here, this is illustrated by showing how the harvesting objective can be maximized, subject to the constraint that the transducer voltages be maintained below that of the power-electronic bus; a condition which is required for the power-electronic control system to be fully operational. Although the theory is applicable across a broad range of applications, it is presented in the context of a piezoelectric bimorph example.

  1. Statistical power to detect violation of the proportional hazards assumption when using the Cox regression model.

    PubMed

    Austin, Peter C

    2018-01-01

    The use of the Cox proportional hazards regression model is widespread. A key assumption of the model is that of proportional hazards. Analysts frequently test the validity of this assumption using statistical significance testing. However, the statistical power of such assessments is frequently unknown. We used Monte Carlo simulations to estimate the statistical power of two different methods for detecting violations of this assumption. When the covariate was binary, we found that a model-based method had greater power than a method based on cumulative sums of martingale residuals. Furthermore, the parametric nature of the distribution of event times had an impact on power when the covariate was binary. Statistical power to detect a strong violation of the proportional hazards assumption was low to moderate even when the number of observed events was high. In many data sets, power to detect a violation of this assumption is likely to be low to modest.

  2. Statistical power to detect violation of the proportional hazards assumption when using the Cox regression model

    PubMed Central

    Austin, Peter C.

    2017-01-01

    The use of the Cox proportional hazards regression model is widespread. A key assumption of the model is that of proportional hazards. Analysts frequently test the validity of this assumption using statistical significance testing. However, the statistical power of such assessments is frequently unknown. We used Monte Carlo simulations to estimate the statistical power of two different methods for detecting violations of this assumption. When the covariate was binary, we found that a model-based method had greater power than a method based on cumulative sums of martingale residuals. Furthermore, the parametric nature of the distribution of event times had an impact on power when the covariate was binary. Statistical power to detect a strong violation of the proportional hazards assumption was low to moderate even when the number of observed events was high. In many data sets, power to detect a violation of this assumption is likely to be low to modest. PMID:29321694

  3. Influence of sex on performance fatigability of the plantar flexors following repeated maximal dynamic shortening contractions.

    PubMed

    Lanning, Amelia C; Power, Geoffrey A; Christie, Anita D; Dalton, Brian H

    2017-10-01

    The purpose was to determine sex differences in fatigability during maximal, unconstrained velocity, shortening plantar flexions. The role of time-dependent measures (i.e., rate of torque development, rate of velocity development, and rate of neuromuscular activation) in such sex-related differences was also examined. By task termination, females exhibited smaller reductions in power and similar changes in rate of neuromuscular activation than males, indicating females were less fatigable than males.

  4. Planning Routes Across Economic Terrains: Maximizing Utility, Following Heuristics

    PubMed Central

    Zhang, Hang; Maddula, Soumya V.; Maloney, Laurence T.

    2010-01-01

    We designed an economic task to investigate human planning of routes in landscapes where travel in different kinds of terrain incurs different costs. Participants moved their finger across a touch screen from a starting point to a destination. The screen was divided into distinct kinds of terrain and travel within each kind of terrain imposed a cost proportional to distance traveled. We varied costs and spatial configurations of terrains and participants received fixed bonuses minus the total cost of the routes they chose. We first compared performance to a model maximizing gain. All but one of 12 participants failed to adopt least-cost routes and their failure to do so reduced their winnings by about 30% (median value). We tested in detail whether participants’ choices of routes satisfied three necessary conditions (heuristics) for a route to maximize gain. We report failures of one heuristic for 7 out of 12 participants. Last of all, we modeled human performance with the assumption that participants assign subjective utilities to costs and maximize utility. For 7 out 12 participants, the fitted utility function was an accelerating power function of actual cost and for the remaining 5, a decelerating power function. We discuss connections between utility aggregation in route planning and decision under risk. Our task could be adapted to investigate human strategy and optimality of route planning in full-scale landscapes. PMID:21833269

  5. Determination of Strength Exercise Intensities Based on the Load-Power-Velocity Relationship

    PubMed Central

    Jandačka, Daniel; Beremlijski, Petr

    2011-01-01

    The velocity of movement and applied load affect the production of mechanical power output and subsequently the extent of the adaptation stimulus in strength exercises. We do not know of any known function describing the relationship of power and velocity and load in the bench press exercise. The objective of the study is to find a function modeling of the relationship of relative velocity, relative load and mechanical power output for the bench press exercise and to determine the intensity zones of the exercise for specifically focused strength training of soccer players. Fifteen highly trained soccer players at the start of a competition period were studied. The subjects of study performed bench presses with the load of 0, 10, 30, 50, 70 and 90% of the predetermined one repetition maximum with maximum possible speed of movement. The mean measured power and velocity for each load (kg) were used to develop a multiple linear regression function which describes the quadratic relationship between the ratio of power (W) to maximum power (W) and the ratios of the load (kg) to one repetition maximum (kg) and the velocity (m•s−1) to maximal velocity (m•s−1). The quadratic function of two variables that modeled the searched relationship explained 74% of measured values in the acceleration phase and 75% of measured values from the entire extent of the positive power movement in the lift. The optimal load for reaching maximum power output suitable for the dynamics effort strength training was 40% of one repetition maximum, while the optimal mean velocity would be 75% of maximal velocity. Moreover, four zones: maximum power, maximum velocity, velocity-power and strength-power were determined on the basis of the regression function. PMID:23486484

  6. Determination of strength exercise intensities based on the load-power-velocity relationship.

    PubMed

    Jandačka, Daniel; Beremlijski, Petr

    2011-06-01

    The velocity of movement and applied load affect the production of mechanical power output and subsequently the extent of the adaptation stimulus in strength exercises. We do not know of any known function describing the relationship of power and velocity and load in the bench press exercise. The objective of the study is to find a function modeling of the relationship of relative velocity, relative load and mechanical power output for the bench press exercise and to determine the intensity zones of the exercise for specifically focused strength training of soccer players. Fifteen highly trained soccer players at the start of a competition period were studied. The subjects of study performed bench presses with the load of 0, 10, 30, 50, 70 and 90% of the predetermined one repetition maximum with maximum possible speed of movement. The mean measured power and velocity for each load (kg) were used to develop a multiple linear regression function which describes the quadratic relationship between the ratio of power (W) to maximum power (W) and the ratios of the load (kg) to one repetition maximum (kg) and the velocity (m•s(-1)) to maximal velocity (m•s(-1)). The quadratic function of two variables that modeled the searched relationship explained 74% of measured values in the acceleration phase and 75% of measured values from the entire extent of the positive power movement in the lift. The optimal load for reaching maximum power output suitable for the dynamics effort strength training was 40% of one repetition maximum, while the optimal mean velocity would be 75% of maximal velocity. Moreover, four zones: maximum power, maximum velocity, velocity-power and strength-power were determined on the basis of the regression function.

  7. Explorations in Statistics: Power

    ERIC Educational Resources Information Center

    Curran-Everett, Douglas

    2010-01-01

    Learning about statistics is a lot like learning about science: the learning is more meaningful if you can actively explore. This fifth installment of "Explorations in Statistics" revisits power, a concept fundamental to the test of a null hypothesis. Power is the probability that we reject the null hypothesis when it is false. Four…

  8. An Examination of Statistical Power in Multigroup Dynamic Structural Equation Models

    ERIC Educational Resources Information Center

    Prindle, John J.; McArdle, John J.

    2012-01-01

    This study used statistical simulation to calculate differential statistical power in dynamic structural equation models with groups (as in McArdle & Prindle, 2008). Patterns of between-group differences were simulated to provide insight into how model parameters influence power approximations. Chi-square and root mean square error of…

  9. The Impacts of Wind Speed Trends and 30-Year Variability in Relation to Hydroelectric Reservoir Inflows on Wind Power in the Pacific Northwest.

    PubMed

    Cross, Benjamin D; Kohfeld, Karen E; Bailey, Joseph; Cooper, Andrew B

    2015-01-01

    In hydroelectric dominated systems, the value and benefits of energy are higher during extended dry periods and lower during extended or extreme wet periods. By accounting for regional and temporal differences in the relationship between wind speed and reservoir inflow behavior during wind farm site selection, the benefits of energy diversification can be maximized. The goal of this work was to help maximize the value of wind power by quantifying the long-term (30-year) relationships between wind speed and streamflow behavior, using British Columbia (BC) and the Pacific Northwest (PNW) as a case study. Clean energy and self-sufficiency policies in British BC make the benefits of increased generation during low streamflow periods particularly large. Wind density (WD) estimates from a height of 10m (North American Regional Reanalysis, NARR) were correlated with cumulative usable inflows (CUI) for BC (collected from BC Hydro) for 1979-2010. The strongest WD-CUI correlations were found along the US coast (r ~0.55), whereas generally weaker correlations were found in northern regions, with negative correlations (r ~ -0.25) along BC's North Coast. Furthermore, during the lowest inflow years, WD anomalies increased by up to 40% above average values for the North Coast. Seasonally, high flows during the spring freshet were coincident with widespread negative WD anomalies, with a similar but opposite pattern for low inflow winter months. These poorly or negatively correlated sites could have a moderating influence on climate related variability in provincial electricity supply, by producing greater than average generation in low inflow years and reduced generation in wet years. Wind speed and WD trends were also analyzed for all NARR grid locations, which showed statistically significant positive trends for most of the PNW and the largest increases along the Pacific Coast.

  10. The Impacts of Wind Speed Trends and 30-Year Variability in Relation to Hydroelectric Reservoir Inflows on Wind Power in the Pacific Northwest

    PubMed Central

    Cross, Benjamin D.; Kohfeld, Karen E.; Bailey, Joseph; Cooper, Andrew B.

    2015-01-01

    In hydroelectric dominated systems, the value and benefits of energy are higher during extended dry periods and lower during extended or extreme wet periods. By accounting for regional and temporal differences in the relationship between wind speed and reservoir inflow behavior during wind farm site selection, the benefits of energy diversification can be maximized. The goal of this work was to help maximize the value of wind power by quantifying the long-term (30-year) relationships between wind speed and streamflow behavior, using British Columbia (BC) and the Pacific Northwest (PNW) as a case study. Clean energy and self-sufficiency policies in British BC make the benefits of increased generation during low streamflow periods particularly large. Wind density (WD) estimates from a height of 10m (North American Regional Reanalysis, NARR) were correlated with cumulative usable inflows (CUI) for BC (collected from BC Hydro) for 1979–2010. The strongest WD-CUI correlations were found along the US coast (r ~0.55), whereas generally weaker correlations were found in northern regions, with negative correlations (r ~ -0.25) along BC’s North Coast. Furthermore, during the lowest inflow years, WD anomalies increased by up to 40% above average values for the North Coast. Seasonally, high flows during the spring freshet were coincident with widespread negative WD anomalies, with a similar but opposite pattern for low inflow winter months. These poorly or negatively correlated sites could have a moderating influence on climate related variability in provincial electricity supply, by producing greater than average generation in low inflow years and reduced generation in wet years. Wind speed and WD trends were also analyzed for all NARR grid locations, which showed statistically significant positive trends for most of the PNW and the largest increases along the Pacific Coast. PMID:26271035

  11. Lactate Parameters Predict Clinical Outcomes in Patients with Nonvariceal Upper Gastrointestinal Bleeding.

    PubMed

    Lee, Seung Hoon; Min, Yang Won; Bae, Joohwan; Lee, Hyuk; Min, Byung Hoon; Lee, Jun Haeng; Rhee, Poong Lyul; Kim, Jae J

    2017-11-01

    The predictive role of lactate in patients with nonvariceal upper gastrointestinal bleeding (NVUGIB) has been suggested. This study evaluated several lactate parameters in terms of predicting outcomes of bleeding patients and sought to establish a new scoring model by combining lactate parameters and the AIMS65 score. A total of 114 patients with NVUGIB who underwent serum lactate level testing at least twice and endoscopic hemostasis within 24 hours after admission were retrospectively analyzed. The associations between five lactate parameters and clinical outcomes were evaluated and the predictive power of lactate parameter combined AIMS65s (L-AIMS65s) and AIMS56 scoring was compared. The most common cause of bleeding was gastric ulcer (48.2%). Lactate clearance rate (LCR) was associated with 30-day rebleeding (odds ratio [OR], 0.931; 95% confidence interval [CI], 0.872-0.994; P = 0.033). Initial lactate (OR, 1.313; 95% CI, 1.050-1.643; P = 0.017), maximal lactate (OR, 1.277; 95% CI, 1.037-1.573; P = 0.021), and average lactate (OR, 1.535; 95% CI, 1.137-2.072; P = 0.005) levels were associated with 30-day mortality. Initial lactate (OR, 1.213; 95% CI, 1.027-1.432; P = 0.023), maximal lactate (OR, 1.271; 95% CI, 1.074-1.504; P = 0.005), and average lactate (OR, 1.501; 95% CI, 1.150-1.959; P = 0.003) levels were associated with admission over 7 days. Although L-AIMS65s showed the highest area under the curve for prediction of each outcome, differences between L-AIMS65s and AIMS65 did not reach statistical significance. In conclusion, lactate parameters have a prognostic role in patients with NVUGIB. However, they do not increase the predictive power of AIMS65 when combined. © 2017 The Korean Academy of Medical Sciences.

  12. COOPERATIVE ROUTING FOR DYNAMIC AERIAL LAYER NETWORKS

    DTIC Science & Technology

    2018-03-01

    Advisor, Computing & Communications Division Information Directorate This report is published in the interest of scientific and technical...information accumulation at the physical layer, and study the cooperative routing and resource allocation problems associated with such SU networks...interference power constraint is studied . In [Shi2012Joint], an optimal power and sub-carrier allocation strategy to maximize SUs’ throughput subject to

  13. Maximal and submaximal endurance performance in adults with severe haemophilia.

    PubMed

    Herbsleb, M; Hilberg, T

    2009-01-01

    Maximal exercise testing, including the determination of maximal performance and maximal oxygen uptake (VO(2max)), is considered the gold standard for assessing maximal endurance performance. The effectiveness of such testing is often reduced in haemophilic adults owing to musculoskeletal impairments or pain rather than because of cardiac exertion. The measurement of submaximal performance parameters overcomes many limitations of maximal exercise testing but a testing standard is still lacking. The aim of this study was to investigate maximal and particularly submaximal endurance performance of adult patients with severe haemophilia A and B. Eleven patients and 11 matched healthy controls were tested by spiroergometry with a specific treadmill test and the power was calculated in Watts. The haemophilic group achieved lower absolute (210 +/- 63 W) and weight-related (2.94 +/- 0.98 W kg(-1)) maximal endurance performance compared with the control group (287 +/- 50 W resp. 3.82 +/- 0.53 W kg(-1); P

  14. Electric power annual 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The Electric Power Annual presents a summary of electric utility statistics at national, regional and State levels. The objective of the publication is to provide industry decisionmakers, government policymakers, analysts and the general public with historical data that may be used in understanding US electricity markets. The Electric Power Annual is prepared by the Survey Management Division; Office of Coal, Nuclear, Electric and Alternate Fuels; Energy Information Administration (EIA); US Department of Energy. ``The US Electric Power Industry at a Glance`` section presents a profile of the electric power industry ownership and performance, and a review of key statistics formore » the year. Subsequent sections present data on generating capability, including proposed capability additions; net generation; fossil-fuel statistics; retail sales; revenue; financial statistics; environmental statistics; electric power transactions; demand-side management; and nonutility power producers. In addition, the appendices provide supplemental data on major disturbances and unusual occurrences in US electricity power systems. Each section contains related text and tables and refers the reader to the appropriate publication that contains more detailed data on the subject matter. Monetary values in this publication are expressed in nominal terms.« less

  15. Laboratory versus outdoor cycling conditions: differences in pedaling biomechanics.

    PubMed

    Bertucci, William; Grappe, Frederic; Groslambert, Alain

    2007-05-01

    The aim of our study was to compare crank torque profile and perceived exertion between the Monark ergometer (818 E) and two outdoor cycling conditions: level ground and uphill road cycling. Seven male cyclists performed seven tests in seated position at different pedaling cadences: (a) in the laboratory at 60, 80, and 100 rpm; (b) on level terrain at 80 and 100 rpm; and (c) on uphill terrain (9.25% grade) at 60 and 80 rpm. The cyclists exercised for 1 min at their maximal aerobic power. The Monark ergometer and the bicycle were equipped with the SRM Training System (Schoberer, Germany) for the measurement of power output (W), torque (Nxm), pedaling cadence (rpm), and cycling velocity (kmxh-1). The most important findings of this study indicate that at maximal aerobic power the crank torque profiles in the Monark ergometer (818 E) were significantly different (especially on dead points of the crank cycle) and generate a higher perceived exertion compared with road cycling conditions.

  16. Optimum electric utility spot price determinations for small power producing facilities operating under PURPA provisions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghoudjehbaklou, H.; Puttgen, H.B.

    This paper outlines an optimum spot price determination procedure in the general context of the Public Utility Regulatory Policies Act, PURPA, provisions. PURPA stipulates that local utilities must offer to purchase all available excess electric energy from Qualifying Facilities, QF, at fair market prices. As a direct consequence of these PURPA regulations, a growing number of owners are installing power producing facilities and optimize their operational schedules to minimize their utility related costs or, in some cases, actually maximize their revenues from energy sales to the local utility. In turn, the utility strives to use spot prices which maximize itsmore » revenues from any given Small Power Producing Facility, SPPF, a schedule while respecting the general regulatory and contractual framework. the proposed optimum spot price determination procedure fully models the SPPF operation, it enforces the contractual and regulatory restrictions, and it ensures the uniqueness of the optimum SPPF schedule.« less

  17. Optimum electric utility spot price determinations for small power producing facilities operating under PURPA provisions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghoudjehbaklou, H.; Puttgen, H.B.

    The present paper outlines an optimum spot price determination procedure in the general context of the Public Utility Regulatory Policies Act, PURPA, provisions. PURPA stipulates that local utilities must offer to purchase all available excess electric energy from Qualifying Facilities, QF, at fair market prices. As a direct consequence of these PURPA regulations, a growing number of owners are installing power producing facilities and optimize their operational schedules to minimize their utility related costs or, in some cases, actually maximize their revenues from energy sales to the local utility. In turn, the utility will strive to use spot prices whichmore » maximize its revenues from any given Small Power Producing Facility, SPPF, schedule while respecting the general regulatory and contractual framework. The proposed optimum spot price determination procedure fully models the SPPF operation, it enforces the contractual and regulatory restrictions, and it ensures the uniqueness of the optimum SPPF schedule.« less

  18. Correlation between morphometry of the suprascapular notch and anthropometric measurements of the scapula.

    PubMed

    Polguj, M; Jędrzejewski, K S; Podgórski, M; Topol, M

    2011-05-01

    The concept of the study was to find the correlation between the morphometry of the suprascapular notch and basic anthropometric measurements of the human scapula. The measurements of the human scapulae included: morphological length and width, maximal width and length projection of scapular spine, length of acromion, and maximal length of the coracoid process. The glenoid cavity was measured in two perpendicular directions to evaluate its width and length. The width-length scapular and glenoid cavity indexes were calculated for every bone. In addition to standard anthropometric measurements two other measurements were defined and evaluated for every suprascapular notch: maximal depth (MD) and superior transverse diameter (STD). The superior transverse suprascapular ligament was completely ossified in 7% of cases. Ten (11.6%) scapulae had a discrete notch. In the studied material, in 21 (24.4%) scapulae the MD was longer than the STD. Two (2.3%) scapulae had equal maximal depth and superior transverse diameter. In 47 (57.7%) scapulae the superior transverse diameter was longer than the maximal depth. There was no statistically significant difference between anthropometric measurements in the group with higher MD and the group with higher STD. The maximal depth of the suprascapular notch negatively correlated with the scapular width-length index. The maximal depth of the scapular notch correlated with the morphological length of the scapulae.

  19. Generalized t-statistic for two-group classification.

    PubMed

    Komori, Osamu; Eguchi, Shinto; Copas, John B

    2015-06-01

    In the classic discriminant model of two multivariate normal distributions with equal variance matrices, the linear discriminant function is optimal both in terms of the log likelihood ratio and in terms of maximizing the standardized difference (the t-statistic) between the means of the two distributions. In a typical case-control study, normality may be sensible for the control sample but heterogeneity and uncertainty in diagnosis may suggest that a more flexible model is needed for the cases. We generalize the t-statistic approach by finding the linear function which maximizes a standardized difference but with data from one of the groups (the cases) filtered by a possibly nonlinear function U. We study conditions for consistency of the method and find the function U which is optimal in the sense of asymptotic efficiency. Optimality may also extend to other measures of discriminatory efficiency such as the area under the receiver operating characteristic curve. The optimal function U depends on a scalar probability density function which can be estimated non-parametrically using a standard numerical algorithm. A lasso-like version for variable selection is implemented by adding L1-regularization to the generalized t-statistic. Two microarray data sets in the study of asthma and various cancers are used as motivating examples. © 2014, The International Biometric Society.

  20. Proof of concept demonstration of optimal composite MRI endpoints for clinical trials.

    PubMed

    Edland, Steven D; Ard, M Colin; Sridhar, Jaiashre; Cobia, Derin; Martersteck, Adam; Mesulam, M Marsel; Rogalski, Emily J

    2016-09-01

    Atrophy measures derived from structural MRI are promising outcome measures for early phase clinical trials, especially for rare diseases such as primary progressive aphasia (PPA), where the small available subject pool limits our ability to perform meaningfully powered trials with traditional cognitive and functional outcome measures. We investigated a composite atrophy index in 26 PPA participants with longitudinal MRIs separated by two years. Rogalski et al . [ Neurology 2014;83:1184-1191] previously demonstrated that atrophy of the left perisylvian temporal cortex (PSTC) is a highly sensitive measure of disease progression in this population and a promising endpoint for clinical trials. Using methods described by Ard et al . [ Pharmaceutical Statistics 2015;14:418-426], we constructed a composite atrophy index composed of a weighted sum of volumetric measures of 10 regions of interest within the left perisylvian cortex using weights that maximize signal-to-noise and minimize sample size required of trials using the resulting score. Sample size required to detect a fixed percentage slowing in atrophy in a two-year clinical trial with equal allocation of subjects across arms and 90% power was calculated for the PSTC and optimal composite surrogate biomarker endpoints. The optimal composite endpoint required 38% fewer subjects to detect the same percent slowing in atrophy than required by the left PSTC endpoint. Optimal composites can increase the power of clinical trials and increase the probability that smaller trials are informative, an observation especially relevant for PPA, but also for related neurodegenerative disorders including Alzheimer's disease.

  1. Response surface methodology as an approach to determine optimal activities of lipase entrapped in sol-gel matrix using different vegetable oils.

    PubMed

    Pinheiro, Rubiane C; Soares, Cleide M F; de Castro, Heizir F; Moraes, Flavio F; Zanin, Gisella M

    2008-03-01

    The conditions for maximization of the enzymatic activity of lipase entrapped in sol-gel matrix were determined for different vegetable oils using an experimental design. The effects of pH, temperature, and biocatalyst loading on lipase activity were verified using a central composite experimental design leading to a set of 13 assays and the surface response analysis. For canola oil and entrapped lipase, statistical analyses showed significant effects for pH and temperature and also the interactions between pH and temperature and temperature and biocatalyst loading. For the olive oil and entrapped lipase, it was verified that the pH was the only variable statistically significant. This study demonstrated that response surface analysis is a methodology appropriate for the maximization of the percentage of hydrolysis, as a function of pH, temperature, and lipase loading.

  2. GWAR: robust analysis and meta-analysis of genome-wide association studies.

    PubMed

    Dimou, Niki L; Tsirigos, Konstantinos D; Elofsson, Arne; Bagos, Pantelis G

    2017-05-15

    In the context of genome-wide association studies (GWAS), there is a variety of statistical techniques in order to conduct the analysis, but, in most cases, the underlying genetic model is usually unknown. Under these circumstances, the classical Cochran-Armitage trend test (CATT) is suboptimal. Robust procedures that maximize the power and preserve the nominal type I error rate are preferable. Moreover, performing a meta-analysis using robust procedures is of great interest and has never been addressed in the past. The primary goal of this work is to implement several robust methods for analysis and meta-analysis in the statistical package Stata and subsequently to make the software available to the scientific community. The CATT under a recessive, additive and dominant model of inheritance as well as robust methods based on the Maximum Efficiency Robust Test statistic, the MAX statistic and the MIN2 were implemented in Stata. Concerning MAX and MIN2, we calculated their asymptotic null distributions relying on numerical integration resulting in a great gain in computational time without losing accuracy. All the aforementioned approaches were employed in a fixed or a random effects meta-analysis setting using summary data with weights equal to the reciprocal of the combined cases and controls. Overall, this is the first complete effort to implement procedures for analysis and meta-analysis in GWAS using Stata. A Stata program and a web-server are freely available for academic users at http://www.compgen.org/tools/GWAR. pbagos@compgen.org. Supplementary data are available at Bioinformatics online. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  3. Effect of short-term cold-water immersion on muscle pain sensitivity in elite track cyclists.

    PubMed

    Klich, Sebastian; Krymski, Igor; Michalik, Kamil; Kawczyński, Adam

    2018-05-01

    To determine the effect of short-term cold-water immersion (CWI) on muscle pain sensitivity after maximal anaerobic power training in track cyclists. Repeated measures. University Laboratory. 12 elite sprint track cyclists (age 24,75 ± 4,23 years). PPT measurements were made on dominant lower extremity (right) in 20 reference points, including anterior thigh muscles, posterior thigh muscles and posterior cuff muscles. PPT levels were measured: 1) before workout, 2) immediately after workout, but before CWI 3) 1 h after CWI and 4) 12 h after CWI. Mean PPT values for each muscle group per participant were calculated for further statistical analysis. The average PPT for anterior thigh muscles decreased significantly after effort (p = 0.001) and increased significantly 1 h after CWI (p = 0.048). In posterior thigh muscles PPT decreased significantly after effort (p = 0.014) and increased significantly 1 h and 12 h after CWI (p = 0.045 and p = 0.25 respectively). However, in posterior cuff muscles PPT decreased only after effort (p = 0.001). Short-term repeated sprint exercise appears to affect PPT in track cyclists. This study have reported that CWI in 5 °C for 5 min have had a beneficial effect in minimizing PPT 1 h post repeated maximal sprint training. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Exercise Capacity and Selected Physiological Factors by Ancestry and Residential Altitude: Cross-Sectional Studies of 9–10-Year-Old Children in Tibet

    PubMed Central

    Berntsen, Sveinung; Andersen, Lars Bo; Stigum, Hein; Ouzhuluobu; Nafstad, Per; Wu, Tianyi; Bjertness, Espen

    2014-01-01

    Abstract Bianba, Sveinung Bernsten, Lars Bo Andersen, Hein Stegum, Ouzhuluobu, Per Nafstad, Tianyi Wu, and Espen Bjertness. Exercise capacity and selected physiological factors by ancestry and residential altitude—Cross-sectional studies of 9–10-year-old children in Tibet. High Alt Med Biol. 15:162–169, 2014.—Aim: Several physiological compensatory mechanisms have enabled Tibetans to live and work at high altitude, including increased ventilation and pulmonary diffusion capacity, both of which serve to increase oxygen transport in the blood. The aim of the present study was to compare exercise capacity (maximal power output) and selected physiological factors (arterial oxygen saturation and heart rate at rest and during maximal exercise, resting hemoglobin concentration, and forced vital capacity) in groups of native Tibetan children living at different residential altitudes (3700 vs. 4300 m above sea level) and across ancestry (native Tibetan vs. Han Chinese children living at the same altitude of 3700 m). Methods: A total of 430 9–10-year-old native Tibetan children from Tingri (4300 m) and 406 native Tibetan- and 406 Han Chinese immigrants (77% lowland-born and 33% highland-born) from Lhasa (3700 m) participated in two cross-sectional studies. The maximal power output (Wmax) was assessed using an ergometer cycle. Results: Lhasa Tibetan children had a 20% higher maximal power output (watts/kg) than Tingri Tibetan and 4% higher than Lhasa Han Chinese. Maximal heart rate, arterial oxygen saturation at rest, lung volume, and arterial oxygen saturation were significantly associated with exercise capacity at a given altitude, but could not fully account for the differences in exercise capacity observed between ancestry groups or altitudes. Conclusions: The superior exercise capacity in native Tibetans vs. Han Chinese may reflect a better adaptation to life at high altitude. Tibetans at the lower residential altitude of 3700 m demonstrated a better exercise capacity than residents at a higher altitude of 4300 m when measured at their respective residential altitudes. Such altitude- or ancestry-related difference could not be fully attributed to the physiological factors measured. PMID:24836751

  5. Charging power optimization for nonlinear vibration energy harvesting systems subjected to arbitrary, persistent base excitations

    NASA Astrophysics Data System (ADS)

    Dai, Quanqi; Harne, Ryan L.

    2018-01-01

    The vibrations of mechanical systems and structures are often a combination of periodic and random motions. Emerging interest to exploit nonlinearities in vibration energy harvesting systems for charging microelectronics may be challenged by such reality due to the potential to transition between favorable and unfavorable dynamic regimes for DC power delivery. Therefore, a need exists to devise an optimization method whereby charging power from nonlinear energy harvesters remains maximized when excitation conditions are neither purely harmonic nor purely random, which have been the attention of past research. This study meets the need by building from an analytical approach that characterizes the dynamic response of nonlinear energy harvesting platforms subjected to combined harmonic and stochastic base accelerations. Here, analytical expressions are formulated and validated to optimize charging power while the influences of the relative proportions of excitation types are concurrently assessed. It is found that about a 2 times deviation in optimal resistive loads can reduce the charging power by 20% when the system is more prominently driven by harmonic base accelerations, whereas a greater proportion of stochastic excitation results in a 11% reduction in power for the same resistance deviation. In addition, the results reveal that when the frequency of a predominantly harmonic excitation deviates by 50% from optimal conditions the charging power reduces by 70%, whereas the same frequency deviation for a more stochastically dominated excitation reduce total DC power by only 20%. These results underscore the need for maximizing direct current power delivery for nonlinear energy harvesting systems in practical operating environments.

  6. Cluster Computing for Embedded/Real-Time Systems

    NASA Technical Reports Server (NTRS)

    Katz, D.; Kepner, J.

    1999-01-01

    Embedded and real-time systems, like other computing systems, seek to maximize computing power for a given price, and thus can significantly benefit from the advancing capabilities of cluster computing.

  7. Sensitivity of sensor-based sit-to-stand peak power to the effects of training leg strength, leg power and balance in older adults.

    PubMed

    Regterschot, G Ruben H; Folkersma, Marjanne; Zhang, Wei; Baldus, Heribert; Stevens, Martin; Zijlstra, Wiebren

    2014-01-01

    Increasing leg strength, leg power and overall balance can improve mobility and reduce fall risk. Sensor-based assessment of peak power during the sit-to-stand (STS) transfer may be useful for detecting changes in mobility and fall risk. Therefore, this study investigated whether sensor-based STS peak power and related measures are sensitive to the effects of increasing leg strength, leg power and overall balance in older adults. A further aim was to compare sensitivity between sensor-based STS measures and standard clinical measures of leg strength, leg power, balance, mobility and fall risk, following an exercise-based intervention. To achieve these aims, 26 older adults (age: 70-84 years) participated in an eight-week exercise program aimed at improving leg strength, leg power and balance. Before and after the intervention, performance on normal and fast STS transfers was evaluated with a hybrid motion sensor worn on the hip. In addition, standard clinical tests (isometric quadriceps strength, Timed Up and Go test, Berg Balance Scale) were performed. Standard clinical tests as well as sensor-based measures of peak power, maximal velocity and duration of normal and fast STS showed significant improvements. Sensor-based measurement of peak power, maximal velocity and duration of normal STS demonstrated a higher sensitivity (absolute standardized response mean (SRM): ≥ 0.69) to the effects of training leg strength, leg power and balance than standard clinical measures (absolute SRM: ≤ 0.61). Therefore, the presented sensor-based method appears to be useful for detecting changes in mobility and fall risk. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Designing Intervention Studies: Selected Populations, Range Restrictions, and Statistical Power

    ERIC Educational Resources Information Center

    Miciak, Jeremy; Taylor, W. Pat; Stuebing, Karla K.; Fletcher, Jack M.; Vaughn, Sharon

    2016-01-01

    An appropriate estimate of statistical power is critical for the design of intervention studies. Although the inclusion of a pretest covariate in the test of the primary outcome can increase statistical power, samples selected on the basis of pretest performance may demonstrate range restriction on the selection measure and other correlated…

  9. The Importance of Teaching Power in Statistical Hypothesis Testing

    ERIC Educational Resources Information Center

    Olinsky, Alan; Schumacher, Phyllis; Quinn, John

    2012-01-01

    In this paper, we discuss the importance of teaching power considerations in statistical hypothesis testing. Statistical power analysis determines the ability of a study to detect a meaningful effect size, where the effect size is the difference between the hypothesized value of the population parameter under the null hypothesis and the true value…

  10. Designing Intervention Studies: Selected Populations, Range Restrictions, and Statistical Power

    PubMed Central

    Miciak, Jeremy; Taylor, W. Pat; Stuebing, Karla K.; Fletcher, Jack M.; Vaughn, Sharon

    2016-01-01

    An appropriate estimate of statistical power is critical for the design of intervention studies. Although the inclusion of a pretest covariate in the test of the primary outcome can increase statistical power, samples selected on the basis of pretest performance may demonstrate range restriction on the selection measure and other correlated measures. This can result in attenuated pretest-posttest correlations, reducing the variance explained by the pretest covariate. We investigated the implications of two potential range restriction scenarios: direct truncation on a selection measure and indirect range restriction on correlated measures. Empirical and simulated data indicated direct range restriction on the pretest covariate greatly reduced statistical power and necessitated sample size increases of 82%–155% (dependent on selection criteria) to achieve equivalent statistical power to parameters with unrestricted samples. However, measures demonstrating indirect range restriction required much smaller sample size increases (32%–71%) under equivalent scenarios. Additional analyses manipulated the correlations between measures and pretest-posttest correlations to guide planning experiments. Results highlight the need to differentiate between selection measures and potential covariates and to investigate range restriction as a factor impacting statistical power. PMID:28479943

  11. Designing Intervention Studies: Selected Populations, Range Restrictions, and Statistical Power.

    PubMed

    Miciak, Jeremy; Taylor, W Pat; Stuebing, Karla K; Fletcher, Jack M; Vaughn, Sharon

    2016-01-01

    An appropriate estimate of statistical power is critical for the design of intervention studies. Although the inclusion of a pretest covariate in the test of the primary outcome can increase statistical power, samples selected on the basis of pretest performance may demonstrate range restriction on the selection measure and other correlated measures. This can result in attenuated pretest-posttest correlations, reducing the variance explained by the pretest covariate. We investigated the implications of two potential range restriction scenarios: direct truncation on a selection measure and indirect range restriction on correlated measures. Empirical and simulated data indicated direct range restriction on the pretest covariate greatly reduced statistical power and necessitated sample size increases of 82%-155% (dependent on selection criteria) to achieve equivalent statistical power to parameters with unrestricted samples. However, measures demonstrating indirect range restriction required much smaller sample size increases (32%-71%) under equivalent scenarios. Additional analyses manipulated the correlations between measures and pretest-posttest correlations to guide planning experiments. Results highlight the need to differentiate between selection measures and potential covariates and to investigate range restriction as a factor impacting statistical power.

  12. Role of adjacency-matrix degeneracy in maximum-entropy-weighted network models

    NASA Astrophysics Data System (ADS)

    Sagarra, O.; Pérez Vicente, C. J.; Díaz-Guilera, A.

    2015-11-01

    Complex network null models based on entropy maximization are becoming a powerful tool to characterize and analyze data from real systems. However, it is not easy to extract good and unbiased information from these models: A proper understanding of the nature of the underlying events represented in them is crucial. In this paper we emphasize this fact stressing how an accurate counting of configurations compatible with given constraints is fundamental to build good null models for the case of networks with integer-valued adjacency matrices constructed from an aggregation of one or multiple layers. We show how different assumptions about the elements from which the networks are built give rise to distinctively different statistics, even when considering the same observables to match those of real data. We illustrate our findings by applying the formalism to three data sets using an open-source software package accompanying the present work and demonstrate how such differences are clearly seen when measuring network observables.

  13. Optimization of ultrasound-assisted extraction to obtain mycosterols from Agaricus bisporus L. by response surface methodology and comparison with conventional Soxhlet extraction.

    PubMed

    Heleno, Sandrina A; Diz, Patrícia; Prieto, M A; Barros, Lillian; Rodrigues, Alírio; Barreiro, Maria Filomena; Ferreira, Isabel C F R

    2016-04-15

    Ergosterol, a molecule with high commercial value, is the most abundant mycosterol in Agaricus bisporus L. To replace common conventional extraction techniques (e.g. Soxhlet), the present study reports the optimal ultrasound-assisted extraction conditions for ergosterol. After preliminary tests, the results showed that solvents, time and ultrasound power altered the extraction efficiency. Using response surface methodology, models were developed to investigate the favourable experimental conditions that maximize the extraction efficiency. All statistical criteria demonstrated the validity of the proposed models. Overall, ultrasound-assisted extraction with ethanol at 375 W during 15 min proved to be as efficient as the Soxhlet extraction, yielding 671.5 ± 0.5mg ergosterol/100 g dw. However, with n-hexane extracts with higher purity (mg ergosterol/g extract) were obtained. Finally, it was proposed for the removal of the saponification step, which simplifies the extraction process and makes it more feasible for its industrial transference. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Hierarchy in directed random networks.

    PubMed

    Mones, Enys

    2013-02-01

    In recent years, the theory and application of complex networks have been quickly developing in a markable way due to the increasing amount of data from real systems and the fruitful application of powerful methods used in statistical physics. Many important characteristics of social or biological systems can be described by the study of their underlying structure of interactions. Hierarchy is one of these features that can be formulated in the language of networks. In this paper we present some (qualitative) analytic results on the hierarchical properties of random network models with zero correlations and also investigate, mainly numerically, the effects of different types of correlations. The behavior of the hierarchy is different in the absence and the presence of giant components. We show that the hierarchical structure can be drastically different if there are one-point correlations in the network. We also show numerical results suggesting that the hierarchy does not change monotonically with the correlations and there is an optimal level of nonzero correlations maximizing the level of hierarchy.

  15. DynaMIT: the dynamic motif integration toolkit

    PubMed Central

    Dassi, Erik; Quattrone, Alessandro

    2016-01-01

    De-novo motif search is a frequently applied bioinformatics procedure to identify and prioritize recurrent elements in sequences sets for biological investigation, such as the ones derived from high-throughput differential expression experiments. Several algorithms have been developed to perform motif search, employing widely different approaches and often giving divergent results. In order to maximize the power of these investigations and ultimately be able to draft solid biological hypotheses, there is the need for applying multiple tools on the same sequences and merge the obtained results. However, motif reporting formats and statistical evaluation methods currently make such an integration task difficult to perform and mostly restricted to specific scenarios. We thus introduce here the Dynamic Motif Integration Toolkit (DynaMIT), an extremely flexible platform allowing to identify motifs employing multiple algorithms, integrate them by means of a user-selected strategy and visualize results in several ways; furthermore, the platform is user-extendible in all its aspects. DynaMIT is freely available at http://cibioltg.bitbucket.org. PMID:26253738

  16. CALET On-orbit Calibration and Performance

    NASA Astrophysics Data System (ADS)

    Akaike, Yosui; Calet Collaboration

    2017-01-01

    The CALorimetric Electron Telescope (CALET) was installed on the International Space Station (ISS) in August 2015, and has been accumulating high-statistics data to perform high-precision measurements of cosmic ray electrons, nuclei and gamma-rays. CALET has an imaging and a fully active calorimeter, with a total thickness of 30 radiation lengths and 1.3 proton interaction lengths, that allow measurements well into the TeV energy region with excellent energy resolution, 2% for electrons above 100 GeV, and powerful particle identification. CALET's performance has been confirmed by Monte Carlo simulations and beam tests. In order to maximize the detector performance and keep the high resolution for long observation on the ISS, it is required to perform the precise calibration of each detector component. We have therefore evaluated the detector response and monitored it by using penetrating cosmic ray events such as protons and helium nuclei. In this paper, we will present the on-orbit calibration and detector performance of CALET on the ISS. This research was supported by JSPS postdoctral fellowships for research abroad.

  17. Effects of upper-body sprint-interval training on strength and endurance capacities in female cross-country skiers

    PubMed Central

    Vandbakk, Kristine; Welde, Boye; Kruken, Andrea Hovstein; Baumgart, Julia; Ettema, Gertjan; Karlsen, Trine; Sandbakk, Øyvind

    2017-01-01

    This study compared the effects of adding upper-body sprint-intervals or continuous double poling endurance training to the normal training on maximal upper-body strength and endurance capacity in female cross-country skiers. In total, 17 female skiers (age: 18.1±0.8yr, body mass: 60±7 kg, maximal oxygen uptake (VO2max): 3.30±0.37 L.min-1) performed an 8-week training intervention. Here, either two weekly sessions of six to eight 30-s maximal upper-body double poling sprint-intervals (SIG, n = 8) or 45–75 min of continuous low-to-moderate intensity double poling on roller skis (CG, n = 9) were added to their training. Before and after the intervention, the participants were tested for physiological and kinematical responses during submaximal and maximal diagonal and double poling treadmill roller skiing. Additionally, we measured maximal upper-body strength (1RM) and average power at 40% 1RM in a poling-specific strength exercise. SIG improved absolute VO2max in diagonal skiing more than CG (8% vs 2%, p<0.05), and showed a tendency towards higher body-mass normalized VO2max (7% vs 2%, p = 0.07). Both groups had an overall improvement in double poling peak oxygen uptake (10% vs 6% for SIG and CG) (both p<0.01), but no group-difference was observed. SIG improved 1RM strength more than CG (18% vs 10%, p<0.05), while there was a tendency for difference in average power at 40% 1RM (20% vs 14%, p = 0.06). Oxygen cost and kinematics (cycle length and rate) in double poling and diagonal remained unchanged in both groups. In conclusion, our study demonstrates that adding upper-body sprint-interval training is more effective than continuous endurance training in improving upper-body maximal strength and VO2max. PMID:28241030

  18. Predictive ability of a comprehensive incremental test in mountain bike marathon

    PubMed Central

    Schneeweiss, Patrick; Martus, Peter; Niess, Andreas M; Krauss, Inga

    2018-01-01

    Objectives Traditional performance tests in mountain bike marathon (XCM) primarily quantify aerobic metabolism and may not describe the relevant capacities in XCM. We aimed to validate a comprehensive test protocol quantifying its intermittent demands. Methods Forty-nine athletes (38.8±9.1 years; 38 male; 11 female) performed a laboratory performance test, including an incremental test, to determine individual anaerobic threshold (IAT), peak power output (PPO) and three maximal efforts (10 s all-out sprint, 1 min maximal effort and 5 min maximal effort). Within 2 weeks, the athletes participated in one of three XCM races (n=15, n=9 and n=25). Correlations between test variables and race times were calculated separately. In addition, multiple regression models of the predictive value of laboratory outcomes were calculated for race 3 and across all races (z-transformed data). Results All variables were correlated with race times 1, 2 and 3: 10 s all-out sprint (r=−0.72; r=−0.59; r=−0.61), 1 min maximal effort (r=−0.85; r=−0.84; r=−0.82), 5 min maximal effort (r=−0.57; r=−0.85; r=−0.76), PPO (r=−0.77; r=−0.73; r=−0.76) and IAT (r=−0.71; r=−0.67; r=−0.68). The best-fitting multiple regression models for race 3 (r2=0.868) and across all races (r2=0.757) comprised 1 min maximal effort, IAT and body weight. Conclusion Aerobic and intermittent variables correlated least strongly with race times. Their use in a multiple regression model confirmed additional explanatory power to predict XCM performance. These findings underline the usefulness of the comprehensive incremental test to predict performance in that sport more precisely. PMID:29387445

  19. New powerful statistics for alignment-free sequence comparison under a pattern transfer model.

    PubMed

    Liu, Xuemei; Wan, Lin; Li, Jing; Reinert, Gesine; Waterman, Michael S; Sun, Fengzhu

    2011-09-07

    Alignment-free sequence comparison is widely used for comparing gene regulatory regions and for identifying horizontally transferred genes. Recent studies on the power of a widely used alignment-free comparison statistic D2 and its variants D*2 and D(s)2 showed that their power approximates a limit smaller than 1 as the sequence length tends to infinity under a pattern transfer model. We develop new alignment-free statistics based on D2, D*2 and D(s)2 by comparing local sequence pairs and then summing over all the local sequence pairs of certain length. We show that the new statistics are much more powerful than the corresponding statistics and the power tends to 1 as the sequence length tends to infinity under the pattern transfer model. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. New Powerful Statistics for Alignment-free Sequence Comparison Under a Pattern Transfer Model

    PubMed Central

    Liu, Xuemei; Wan, Lin; Li, Jing; Reinert, Gesine; Waterman, Michael S.; Sun, Fengzhu

    2011-01-01

    Alignment-free sequence comparison is widely used for comparing gene regulatory regions and for identifying horizontally transferred genes. Recent studies on the power of a widely used alignment-free comparison statistic D2 and its variants D2∗ and D2s showed that their power approximates a limit smaller than 1 as the sequence length tends to infinity under a pattern transfer model. We develop new alignment-free statistics based on D2, D2∗ and D2s by comparing local sequence pairs and then summing over all the local sequence pairs of certain length. We show that the new statistics are much more powerful than the corresponding statistics and the power tends to 1 as the sequence length tends to infinity under the pattern transfer model. PMID:21723298

  1. Energy Efficiency Maximization of Practical Wireless Communication Systems

    NASA Astrophysics Data System (ADS)

    Eraslan, Eren

    Energy consumption of the modern wireless communication systems is rapidly growing due to the ever-increasing data demand and the advanced solutions employed in order to address this demand, such as multiple-input multiple-output (MIMO) and orthogonal frequency division multiplexing (OFDM) techniques. These MIMO systems are power hungry, however, they are capable of changing the transmission parameters, such as number of spatial streams, number of transmitter/receiver antennas, modulation, code rate, and transmit power. They can thus choose the best mode out of possibly thousands of modes in order to optimize an objective function. This problem is referred to as the link adaptation problem. In this work, we focus on the link adaptation for energy efficiency maximization problem, which is defined as choosing the optimal transmission mode to maximize the number of successfully transmitted bits per unit energy consumed by the link. We model the energy consumption and throughput performances of a MIMO-OFDM link and develop a practical link adaptation protocol, which senses the channel conditions and changes its transmission mode in real-time. It turns out that the brute force search, which is usually assumed in previous works, is prohibitively complex, especially when there are large numbers of transmit power levels to choose from. We analyze the relationship between the energy efficiency and transmit power, and prove that energy efficiency of a link is a single-peaked quasiconcave function of transmit power. This leads us to develop a low-complexity algorithm that finds a near-optimal transmit power and take this dimension out of the search space. We further prune the search space by analyzing the singular value decomposition of the channel and excluding the modes that use higher number of spatial streams than the channel can support. These algorithms and our novel formulations provide simpler computations and limit the search space into a much smaller set; hence reducing the computational complexity by orders of magnitude without sacrificing the performance. The result of this work is a highly practical link adaptation protocol for maximizing the energy efficiency of modern wireless communication systems. Simulation results show orders of magnitude gain in the energy efficiency of the link. We also implemented the link adaptation protocol on real-time MIMO-OFDM radios and we report on the experimental results. To the best of our knowledge, this is the first reported testbed that is capable of performing energy-efficient fast link adaptation using PHY layer information.

  2. Computing an operating parameter of a unified power flow controller

    DOEpatents

    Wilson, David G.; Robinett, III, Rush D.

    2017-12-26

    A Unified Power Flow Controller described herein comprises a sensor that outputs at least one sensed condition, a processor that receives the at least one sensed condition, a memory that comprises control logic that is executable by the processor; and power electronics that comprise power storage, wherein the processor causes the power electronics to selectively cause the power storage to act as one of a power generator or a load based at least in part upon the at least one sensed condition output by the sensor and the control logic, and wherein at least one operating parameter of the power electronics is designed to facilitate maximal transmittal of electrical power generated at a variable power generation system to a grid system while meeting power constraints set forth by the electrical power grid.

  3. Computing an operating parameter of a unified power flow controller

    DOEpatents

    Wilson, David G; Robinett, III, Rush D

    2015-01-06

    A Unified Power Flow Controller described herein comprises a sensor that outputs at least one sensed condition, a processor that receives the at least one sensed condition, a memory that comprises control logic that is executable by the processor; and power electronics that comprise power storage, wherein the processor causes the power electronics to selectively cause the power storage to act as one of a power generator or a load based at least in part upon the at least one sensed condition output by the sensor and the control logic, and wherein at least one operating parameter of the power electronics is designed to facilitate maximal transmittal of electrical power generated at a variable power generation system to a grid system while meeting power constraints set forth by the electrical power grid.

  4. On-Line Thermal Barrier Coating Monitoring for Real-Time Failure Protection and Life Maximization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dennis H. LeMieux

    2004-10-01

    Under the sponsorship of the U. S. Department of Energy's National Energy Laboratory, Siemens Westinghouse Power Corporation proposes a four year program titled, ''On-Line Thermal Barrier Coating (TBC) Monitor for Real-Time Failure Protection and Life Maximization'', to develop, build and install the first generation of an on-line TBC monitoring system for use on land -based advanced gas turbines (AGT). Federal deregulation in electric power generation has accelerated power plant owner's demand for improved reliability availability maintainability (RAM) of the land-based advanced gas turbines. As a result, firing temperatures have been increased substantially in the advanced turbine engines, and the TBCsmore » have been developed for maximum protection and life of all critical engine components operating at these higher temperatures. Losing TBC protection can therefore accelerate the degradation of substrate components materials and eventually lead to a premature failure of critical component and costly unscheduled power outages. This program seeks to substantially improve the operating life of high cost gas turbine components using TBC; thereby, lowering the cost of maintenance leading to lower cost of electricity. Siemens Westinghouse Power Corporation has teamed with Indigo Systems; a supplier of state-of-the-art infrared camera systems, and Wayne State University, a leading research organization.« less

  5. Maintenance of Velocity and Power With Cluster Sets During High-Volume Back Squats.

    PubMed

    Tufano, James J; Conlon, Jenny A; Nimphius, Sophia; Brown, Lee E; Seitz, Laurent B; Williamson, Bryce D; Haff, G Gregory

    2016-10-01

    To compare the effects of a traditional set structure and 2 cluster set structures on force, velocity, and power during back squats in strength-trained men. Twelve men (25.8 ± 5.1 y, 1.74 ± 0.07 m, 79.3 ± 8.2 kg) performed 3 sets of 12 repetitions at 60% of 1-repetition maximum using 3 different set structures: traditional sets (TS), cluster sets of 4 (CS4), and cluster sets of 2 (CS2). When averaged across all repetitions, peak velocity (PV), mean velocity (MV), peak power (PP), and mean power (MP) were greater in CS2 and CS4 than in TS (P < .01), with CS2 also resulting in greater values than CS4 (P < .02). When examining individual sets within each set structure, PV, MV, PP, and MP decreased during the course of TS (effect sizes 0.28-0.99), whereas no decreases were noted during CS2 (effect sizes 0.00-0.13) or CS4 (effect sizes 0.00-0.29). These results demonstrate that CS structures maintain velocity and power, whereas TS structures do not. Furthermore, increasing the frequency of intraset rest intervals in CS structures maximizes this effect and should be used if maximal velocity is to be maintained during training.

  6. Some applications of the most general form of the higher-order GUP with minimal length uncertainty and maximal momentum

    NASA Astrophysics Data System (ADS)

    Shababi, Homa; Chung, Won Sang

    2018-04-01

    In this paper, using the new type of D-dimensional nonperturbative Generalized Uncertainty Principle (GUP) which has predicted both a minimal length uncertainty and a maximal observable momentum,1 first, we obtain the maximally localized states and express their connections to [P. Pedram, Phys. Lett. B 714, 317 (2012)]. Then, in the context of our proposed GUP and using the generalized Schrödinger equation, we solve some important problems including particle in a box and one-dimensional hydrogen atom. Next, implying modified Bohr-Sommerfeld quantization, we obtain energy spectra of quantum harmonic oscillator and quantum bouncer. Finally, as an example, we investigate some statistical properties of a free particle, including partition function and internal energy, in the presence of the mentioned GUP.

  7. IMNN: Information Maximizing Neural Networks

    NASA Astrophysics Data System (ADS)

    Charnock, Tom; Lavaux, Guilhem; Wandelt, Benjamin D.

    2018-04-01

    This software trains artificial neural networks to find non-linear functionals of data that maximize Fisher information: information maximizing neural networks (IMNNs). As compressing large data sets vastly simplifies both frequentist and Bayesian inference, important information may be inadvertently missed. Likelihood-free inference based on automatically derived IMNN summaries produces summaries that are good approximations to sufficient statistics. IMNNs are robustly capable of automatically finding optimal, non-linear summaries of the data even in cases where linear compression fails: inferring the variance of Gaussian signal in the presence of noise, inferring cosmological parameters from mock simulations of the Lyman-α forest in quasar spectra, and inferring frequency-domain parameters from LISA-like detections of gravitational waveforms. In this final case, the IMNN summary outperforms linear data compression by avoiding the introduction of spurious likelihood maxima.

  8. Fisher's method of scoring in statistical image reconstruction: comparison of Jacobi and Gauss-Seidel iterative schemes.

    PubMed

    Hudson, H M; Ma, J; Green, P

    1994-01-01

    Many algorithms for medical image reconstruction adopt versions of the expectation-maximization (EM) algorithm. In this approach, parameter estimates are obtained which maximize a complete data likelihood or penalized likelihood, in each iteration. Implicitly (and sometimes explicitly) penalized algorithms require smoothing of the current reconstruction in the image domain as part of their iteration scheme. In this paper, we discuss alternatives to EM which adapt Fisher's method of scoring (FS) and other methods for direct maximization of the incomplete data likelihood. Jacobi and Gauss-Seidel methods for non-linear optimization provide efficient algorithms applying FS in tomography. One approach uses smoothed projection data in its iterations. We investigate the convergence of Jacobi and Gauss-Seidel algorithms with clinical tomographic projection data.

  9. Statistical optimization of growth medium for the production of the entomopathogenic and phytotoxic cyclic depsipeptide beauvericin from Fusarium oxysporum KFCC 11363P.

    PubMed

    Lee, Hee-Seok; Song, Hyuk-Hwan; An, Joong-Hoon; Shin, Cha-Gyun; Lee, Gung Pyo; Lee, Chan

    2008-01-01

    The production of the entomopathogenic and phytotoxic cyclic depsipeptide beauvericin (BEA) was studied in submerged cultures of Fusarium oxysporum KFCC 11363P isolated in Korea. The influences of various factors on mycelia growth and BEA production were examined in both complete and chemically defined culture media. The mycelia growth and BEA production were highest in Fusarium defined medium. The optimal carbon and nitrogen sources for maximizing BEA production were glucose and NaNO3, respectively. The carbon/ nitrogen ratio for maximal production of BEA was investigated using response surface methodology (RSM). Equations derived by differentiation of the RSM model revealed that the production of BEA was maximal when using 108 mM glucose and 25 mM NaNO3.

  10. Beamspace Multiple Input Multiple Output. Part II: Steerable Antennas in Mobile Ad Hoc Networks

    DTIC Science & Technology

    2016-09-01

    to the transmitter with half the channel transfer function power , since the actual receiver dwells on each channel only half the time. Fourth diagram...steering in a wireless network to maximize signal power and minimize interference [8–10]. The ability to switch beams adds another diversity dimension to...channel transfer function power , since the actual receiver dwells on each channel only half the time. Fourth diagram: The transmit array sends four

  11. Fighting Fire with Fire: Modeling the Datacenter-Scale Effects of Targeted Superlattice Thermal Management

    DTIC Science & Technology

    2011-01-01

    we propose that hot-spot mitigation using thermoelectric coolers can be used as a power management mechanism to allow global coolers to be provi...sioned for a better worst case temperature leading to substan- tial savings in cooling power. In order to quantify the potential power savings from us- ing...energy density inside a processor to maximally tolerable levels, modern microprocessors make ex- tensive use of hardware structures such as the load

  12. Gradient Dynamics and Entropy Production Maximization

    NASA Astrophysics Data System (ADS)

    Janečka, Adam; Pavelka, Michal

    2018-01-01

    We compare two methods for modeling dissipative processes, namely gradient dynamics and entropy production maximization. Both methods require similar physical inputs-how energy (or entropy) is stored and how it is dissipated. Gradient dynamics describes irreversible evolution by means of dissipation potential and entropy, it automatically satisfies Onsager reciprocal relations as well as their nonlinear generalization (Maxwell-Onsager relations), and it has statistical interpretation. Entropy production maximization is based on knowledge of free energy (or another thermodynamic potential) and entropy production. It also leads to the linear Onsager reciprocal relations and it has proven successful in thermodynamics of complex materials. Both methods are thermodynamically sound as they ensure approach to equilibrium, and we compare them and discuss their advantages and shortcomings. In particular, conditions under which the two approaches coincide and are capable of providing the same constitutive relations are identified. Besides, a commonly used but not often mentioned step in the entropy production maximization is pinpointed and the condition of incompressibility is incorporated into gradient dynamics.

  13. Replication Unreliability in Psychology: Elusive Phenomena or “Elusive” Statistical Power?

    PubMed Central

    Tressoldi, Patrizio E.

    2012-01-01

    The focus of this paper is to analyze whether the unreliability of results related to certain controversial psychological phenomena may be a consequence of their low statistical power. Applying the Null Hypothesis Statistical Testing (NHST), still the widest used statistical approach, unreliability derives from the failure to refute the null hypothesis, in particular when exact or quasi-exact replications of experiments are carried out. Taking as example the results of meta-analyses related to four different controversial phenomena, subliminal semantic priming, incubation effect for problem solving, unconscious thought theory, and non-local perception, it was found that, except for semantic priming on categorization, the statistical power to detect the expected effect size (ES) of the typical study, is low or very low. The low power in most studies undermines the use of NHST to study phenomena with moderate or low ESs. We conclude by providing some suggestions on how to increase the statistical power or use different statistical approaches to help discriminate whether the results obtained may or may not be used to support or to refute the reality of a phenomenon with small ES. PMID:22783215

  14. Application of force-velocity cycle ergometer test and vertical jump tests in the functional assessment of karate competitor.

    PubMed

    Ravier, G; Grappe, F; Rouillon, J D

    2004-12-01

    The aim of this study was to analyze the links between tests performances (vertical jump and force-velocity sprint on cycle ergometer) and 2 different karate level groups in order to propose a test battery adjusted to karate. Twenty-two karate competitors (10 national junior team (IJ) and 12 national competition level (NL)) performed 4 maximal squat jumps (SJ), 4 maximal counter movement jumps (CMJ) on an ergojump and 3 8-s sprints on a friction braked cycle ergometer (friction loads of 0.5, 0.7, 0.9 N x kg(-1)). The maximal theoretical force (F(0)) and velocity (V(0)), the maximal power output (P(max)) and the optimal pedalling velocity (V(opt)) were derived from both the force -- velocity and the power -- velocity relationships plotted from all the 3 friction loads data. V(0), F(0), V(opt), P(max) and the best SJ and CMJ, were compared between IJ and NL groups. The IJ group was characterised by significantly higher values of V(0) (+13%) and SJ (+14.3%) compared to NL group, whereas no significant difference was observed between groups for F(0). Thus, karate performance would depend on maximal velocity and explosive strength. In addition, V(opt) was significantly higher in IJ group compared to NL group (135.4 rpm vs 119.2 rpm, p<0.001). Although based upon indirect evidence, these results accounted for mechanical functional capabilities of experts which could be particularly valuable when monitoring training of karate competitor. A force-velocity and a vertical jump tests may be applied in the functional assessment of karate competitor.

  15. Ka-Band Waveguide 2-Way Hybrid Combiner for MMIC Amplifiers with Unequal and Arbitrary Power Output Ratio

    NASA Technical Reports Server (NTRS)

    Simons, Rainee N (Inventor); Chevalier, Christine T (Inventor); Wintucky, Edwin G (Inventor); Freeman, Jon C (Inventor)

    2016-01-01

    One or more embodiments of the present invention describe an apparatus and method to combine unequal powers. The apparatus includes a first input port, a second input port, and a combiner. The first input port is operably connected to a first power amplifier and is configured to receive a first power from the first power amplifier. The second input port is operably connected to a second power amplifier and is configured to receive a second power from the second power amplifier. The combiner is configured to simultaneously receive the first power from the first input port and the second power from the second input port. The combiner is also configured to combine the first power and second power to produce a maximized power. The first power and second power are unequal.

  16. "Using Power Tables to Compute Statistical Power in Multilevel Experimental Designs"

    ERIC Educational Resources Information Center

    Konstantopoulos, Spyros

    2009-01-01

    Power computations for one-level experimental designs that assume simple random samples are greatly facilitated by power tables such as those presented in Cohen's book about statistical power analysis. However, in education and the social sciences experimental designs have naturally nested structures and multilevel models are needed to compute the…

  17. Local heat stress and skin blood flowmotion in subjects with familial predisposition or newly diagnosed hypertension.

    PubMed

    Gryglewska, Barbara; Nęcki, Mirosław; Cwynar, Marcin; Baron, Tomasz; Grodzicki, Tomasz

    2010-12-01

    The aim of the study was to investigate the skin microcirculation blood flow and flowmotion response to heat stress in normotensive subjects with familial predisposition to hypertension and in hypertensive patients. Normotensives without [NT(-)] or with [NT(+)] familial predisposition and subjects with newly diagnosed hypertension (HT) were studied. Clinic blood pressure (BP) measurements and ambulatory BP monitoring as well as laboratory assessments were performed. Resting (RF), heat (HF) and maximal heat (MHF) blood flows were measured using PeriFlux laser Doppler flowmetry (LDF) and expressed as absolute units (AU) and as index of cutaneous vascular conductance (CVC). Spectral analysis of the skin LDF signal was performed by means of the Perisoft dedicated software. Kruskall-Wallis analysis of variance, χ(2) statistic and multivariate reverse regression analysis were used for calculation. The studied population consisted of 70 persons (mean age 36.1 ± 10.3 years, 44.3% women): 17 NT(-), 22 NT(+) and 31 HT, age and gender matched. Higher values of body mass index (BMI), and insulin, glucose and triglyceride levels were observed in HT than in NT groups. RF, HF and MHF were similar in all study groups, but CVC of maximal heat flow differed (p=0.02); in particular, lower values were observed in the HT than in NT(-) group (p=0.01). The study groups differed with regard to total power (p=0.01) and myogenic (p=0.03) origin flowmotion with the lowest values in the NT(+) group. BMI and night BP characteristics were strong predictors of reduction of CVC, MHF and myogenic origin flowmotion. Skin microcirculation response to local heat stress is altered in hypertensive patients with decrease in maximal heat CVC values. Moreover, normotensive subjects with familial predisposition to hypertension are characterized by diminished myogenic origin of skin blood flowmotion.

  18. Automatic phase control in solar power satellite systems

    NASA Technical Reports Server (NTRS)

    Lindsey, W. C.; Kantak, A. V.

    1978-01-01

    Various approaches to the problem of generating, maintaining and distributing a coherent, reference phase signal over a large area are suggested, mathematically modeled and analyzed with respect to their ability to minimize: phase build-up, beam diffusion and beam steering phase jitter, cable length, and maximize power transfer efficiency. In addition, phase control configurations are suggested which alleviate the need for layout symmetry.

  19. Phosphate and acidosis act synergistically to depress peak power in rat muscle fibers.

    PubMed

    Nelson, Cassandra R; Debold, Edward P; Fitts, Robert H

    2014-11-15

    Skeletal muscle fatigue is characterized by the buildup of H(+) and inorganic phosphate (Pi), metabolites that are thought to cause fatigue by inhibiting muscle force, velocity, and power. While the individual effects of elevated H(+) or Pi have been well characterized, the effects of simultaneously elevating the ions, as occurs during fatigue in vivo, are still poorly understood. To address this, we exposed slow and fast rat skinned muscle fibers to fatiguing levels of H(+) (pH 6.2) and Pi (30 mM) and determined the effects on contractile properties. At 30°C, elevated Pi and low pH depressed maximal shortening velocity (Vmax) by 15% (4.23 to 3.58 fl/s) in slow and 31% (6.24 vs. 4.55 fl/s) in fast fibers, values similar to depressions from low pH alone. Maximal isometric force dropped by 36% in slow (148 to 94 kN/m(2)) and 46% in fast fibers (148 to 80 kN/m(2)), declines substantially larger than what either ion exerted individually. The strong effect on force combined with the significant effect on velocity caused peak power to decline by over 60% in both fiber types. Force-stiffness ratios significantly decreased with pH 6.2 + 30 mM Pi in both fiber types, suggesting these ions reduced force by decreasing the force per bridge and/or increasing the number of low-force bridges. The data indicate the collective effects of elevating H(+) and Pi on maximal isometric force and peak power are stronger than what either ion exerts individually and suggest the ions act synergistically to reduce muscle function during fatigue. Copyright © 2014 the American Physiological Society.

  20. Effects of hand configuration on muscle force coordination, co-contraction and concomitant intermuscular coupling during maximal isometric flexion of the fingers.

    PubMed

    Charissou, Camille; Amarantini, David; Baurès, Robin; Berton, Eric; Vigouroux, Laurent

    2017-11-01

    The mechanisms governing the control of musculoskeletal redundancy remain to be fully understood. The hand is highly redundant, and shows different functional role of extensors according to its configuration for a same functional task of finger flexion. Through intermuscular coherence analysis combined with hand musculoskeletal modelling during maximal isometric hand contractions, our aim was to better understand the neural mechanisms underlying the control of muscle force coordination and agonist-antagonist co-contraction. Thirteen participants performed maximal isometric flexions of the fingers in two configurations: power grip (Power) and finger-pressing on a surface (Press). Hand kinematics and force/moment measurements were used as inputs in a musculoskeletal model of the hand to determine muscular tensions and co-contraction. EMG-EMG coherence analysis was performed between wrist and finger flexors and extensor muscle pairs in alpha, beta and gamma frequency bands. Concomitantly with tailored muscle force coordination and increased co-contraction between Press and Power (mean difference: 48.08%; p < 0.05), our results showed muscle-pair-specific modulation of intermuscular coupling, characterized by pair-specific modulation of EMG-EMG coherence between Power and Press (p < 0.05), and a negative linear association between co-contraction and intermuscular coupling for the ECR/FCR agonist-antagonist muscle pair (r = - 0.65; p < 0.05). This study brings new evidence that pair-specific modulation of EMG-EMG coherence is related to modulation of muscle force coordination during hand contractions. Our results highlight the functional importance of intermuscular coupling as a mechanism contributing to the control of muscle force synergies and agonist-antagonist co-contraction.

  1. Differences in Physiological Responses to Interval Training in Cyclists With and Without Interval Training Experience

    PubMed Central

    Hebisz, Rafal; Borkowski, Jacek; Zatoń, Marek

    2016-01-01

    Abstract The aim of this study was to determine differences in glycolytic metabolite concentrations and work output in response to an all-out interval training session in 23 cyclists with at least 2 years of interval training experience (E) and those inexperienced (IE) in this form of training. The intervention involved subsequent sets of maximal intensity exercise on a cycle ergometer. Each set comprised four 30 s repetitions interspersed with 90 s recovery periods; sets were repeated when blood pH returned to 7.3. Measurements of post-exercise hydrogen (H+) and lactate ion (LA-) concentrations and work output were taken. The experienced cyclists performed significantly more sets of maximal efforts than the inexperienced athletes (5.8 ± 1.2 vs. 4.3 ± 0.9 sets, respectively). Work output decreased in each subsequent set in the IE group and only in the last set in the E group. Distribution of power output changed only in the E group; power decreased in the initial repetitions of set only to increase in the final repetitions. H+ concentration decreased in the third, penultimate, and last sets in the E group and in each subsequent set in the IE group. LA- decreased in the last set in both groups. In conclusion, the experienced cyclists were able to repeatedly induce elevated levels of lactic acidosis. Power output distribution changed with decreased acid–base imbalance. In this way, this group could compensate for a decreased anaerobic metabolism. The above factors allowed cyclists experienced in interval training to perform more sets of maximal exercise without a decrease in power output compared with inexperienced cyclists. PMID:28149346

  2. Sprinting performance on the Woodway Curve 3.0 is related to muscle architecture.

    PubMed

    Mangine, Gerald T; Fukuda, David H; Townsend, Jeremy R; Wells, Adam J; Gonzalez, Adam M; Jajtner, Adam R; Bohner, Jonathan D; LaMonica, Michael; Hoffman, Jay R; Fragala, Maren S; Stout, Jeffrey R

    2015-01-01

    To determine if unilateral measures of muscle architecture in the rectus femoris (RF) and vastus lateralis (VL) were related to (and predictive of) sprinting speed and unilateral (and bilateral) force (FRC) and power (POW) during a 30 s maximal sprint on the Woodway Curve 3.0 non-motorized treadmill. Twenty-eight healthy, physically active men (n = 14) and women (n = 14) (age = 22.9 ± 2.4 years; body mass = 77.1 ± 16.2 kg; height = 171.6 ± 11.2 cm; body-fa t = 19.4 ± 8.1%) completed one familiarization and one 30-s maximal sprint on the TM to obtain maximal sprinting speed, POW and FRC. Muscle thickness (MT), cross-sectional area (CSA) and echo intensity (ECHO) of the RF and VL in the dominant (DOM; determined by unilateral sprinting power) and non-dominant (ND) legs were measured via ultrasound. Pearson correlations indicated several significant (p < 0.05) relationships between sprinting performance [POW (peak, DOM and ND), FRC (peak, DOM, ND) and sprinting time] and muscle architecture. Stepwise regression indicated that POW(DOM) was predictive of ipsilateral RF (MT and CSA) and VL (CSA and ECHO), while POW(ND) was predictive of ipsilateral RF (MT and CSA) and VL (CSA); sprinting power/force asymmetry was not predictive of architecture asymmetry. Sprinting time was best predicted by peak power and peak force, though muscle quality (ECHO) and the bilateral percent difference in VL (CSA) were strong architectural predictors. Muscle architecture is related to (and predictive of) TM sprinting performance, while unilateral POW is predictive of ipsilateral architecture. However, the extent to which architecture and other factors (i.e. neuromuscular control and sprinting technique) affect TM performance remains unknown.

  3. Optimal load for the peak power and maximal strength of the upper body in Brazilian Jiu-Jitsu athletes.

    PubMed

    da Silva, Bruno Victor C; Simim, Mário A de Moura; Marocolo, Moacir; Franchini, Emerson; da Mota, Gustavo R

    2015-06-01

    We determined the optimal load for the peak power output (PPO) during the bench press throw (BPT) in Brazilian Jiu-Jitsu (BJJ) athletes and compared the PPO and maximal strength between advanced (AD) and nonadvanced (NA) athletes. Twenty-eight BJJ athletes (24.8 ± 5.7 years) performed the BPT at loads of 30, 40, 50, and 60% of their 1 repetition maximum (RM) in a randomized order (5-minute rest between BPTs). The PPO was determined by measuring the barbell displacement by an accelerometer (Myotest). The absolute (F = 7.25; p < 0.001; effect size [ES] = 0.21) and relative intensities were different (F = 7.11; p < 0.001; ES = 0.21) between the AD and NA. There was also a group and intensity interaction effect (F = 2.79; p = 0.046; ES = 0.10), but the differences were centered around the AD group, which achieved higher values using 40% (p = 0.001) and 50% of the 1RM (p < 0.001) than the PPO with 60% of 1RM. The AD athletes presented with higher 1RM than NA (p ≤ 0.05; ES = 1.0), but there was no difference (p > 0.05) in the PPO (30-60% 1RM). A polynomial adjustment indicated that the optimal load was ∼42% of 1RM for all groups and subgroups (R from 0.82 to 0.99). Our results suggest that there can be (1RM) differences between AD and NA BJJ athletes; however, there is no difference in the muscle power between the AD and NA groups. Additionally, ∼42% of 1RM seems to be the optimal load for developing maximal power using the BPT for the BJJ athletes.

  4. Integrated soldier power and data system (ISPDS)

    NASA Astrophysics Data System (ADS)

    Ostroumov, Roman; Forrester, Thomas; Lee, Kang; Stephens, Robert; Lai, Anthony; Zahzah, Mohamad

    2014-06-01

    Physical Optics Corporation (POC) developed the body-worn Integrated Soldier Power and Data System (ISPDS), a configurable node for plug-in wired or wireless server/client or peer-to-peer computing with accommodations for power, sensor I/O interfaces, and energy harvesting. The enabling technology increases the efficacy of uniformed personnel and first responders and provides an option for reducing force structure associated with the need for hardware network infrastructure to enable a mobile digital communications architecture for dismounted troops. The ISPDS system addresses the DoD's need for an "intelligent" power control system in an effort to increase mission duration and maximize the first responders and warfighter's effectiveness without concern for the available energy resources (i.e., batteries). ISPDS maximizes durability and survivability, assesses influences that affect performance, and provides the network backbone and mobile node hardware. POC is producing two vest-integrated variants, one each for the U.S. Army PEO Ground Soldier and the Air Soldier, with each including state-of-the-art low-profile and robust wearable connectors, cabling, and harnesses, and an integrated low-profile power manager and conformal battery for data and power distribution. The innovative intelligent power controller (IPC), in the form of the ISPDS firmware and power sensing and control electronics, will enable ISPDS to optimize power levels both automatically and in accordance with manually set preferences. The IPC module is power dense and efficient, and adaptively provides lossless transfer of available harvested photovoltaic energy to the battery. The integrated systems were tested for suitable electrical, electromagnetic interference (EMI), and environmental performance as outlined in military standards such as MIL-STD- 810G and MIL STD-461F.

  5. Relationship between arterial oxygen desaturation and ventilation during maximal exercise.

    PubMed

    Miyachi, M; Tabata, I

    1992-12-01

    The purpose of the present study was to investigate the contribution of ventilation to arterial O2 desaturation during maximal exercise. Nine untrained subjects and 22 trained long-distance runners [age 18-36 yr, maximal O2 uptake (VO2max) 48-74 ml.min-1 x kg-1] volunteered to participate in the study. The subjects performed an incremental exhaustive cycle ergometry test at 70 rpm of pedaling frequency, during which arterial O2 saturation (SaO2) and ventilatory data were collected every minute. SaO2 was estimated with a pulse oximeter. A significant positive correlation was found between SaO2 and end-tidal PO2 (PETO2; r = 0.72, r2 = 0.52, P < 0.001) during maximal exercise. These statistical results suggest that approximately 50% of the variability of SaO2 can be accounted for by differences in PETO2, which reflects alveolar PO2. Furthermore, PETO2 was highly correlated with the ventilatory equivalent for O2 (VE/VO2; r = 0.91, P < 0.001), which indicates that PETO2 could be the result of ventilation stimulated by maximal exercise. Finally, SaO2 was positively related to VE/VO2 during maximal exercise (r = 0.74, r2 = 0.55, P < 0.001). Therefore, one-half of the arterial O2 desaturation occurring during maximal exercise may be explained by less hyperventilation, specifically for our subjects, who demonstrated a wide range of trained states. Furthermore, we found an indirect positive correlation between SaO2 and ventilatory response to CO2 at rest (r = 0.45, P < 0.05), which was mediated by ventilation during maximal exercise. These data also suggest that ventilation is an important factor for arterial O2 desaturation during maximal exercise.

  6. A new u-statistic with superior design sensitivity in matched observational studies.

    PubMed

    Rosenbaum, Paul R

    2011-09-01

    In an observational or nonrandomized study of treatment effects, a sensitivity analysis indicates the magnitude of bias from unmeasured covariates that would need to be present to alter the conclusions of a naïve analysis that presumes adjustments for observed covariates suffice to remove all bias. The power of sensitivity analysis is the probability that it will reject a false hypothesis about treatment effects allowing for a departure from random assignment of a specified magnitude; in particular, if this specified magnitude is "no departure" then this is the same as the power of a randomization test in a randomized experiment. A new family of u-statistics is proposed that includes Wilcoxon's signed rank statistic but also includes other statistics with substantially higher power when a sensitivity analysis is performed in an observational study. Wilcoxon's statistic has high power to detect small effects in large randomized experiments-that is, it often has good Pitman efficiency-but small effects are invariably sensitive to small unobserved biases. Members of this family of u-statistics that emphasize medium to large effects can have substantially higher power in a sensitivity analysis. For example, in one situation with 250 pair differences that are Normal with expectation 1/2 and variance 1, the power of a sensitivity analysis that uses Wilcoxon's statistic is 0.08 while the power of another member of the family of u-statistics is 0.66. The topic is examined by performing a sensitivity analysis in three observational studies, using an asymptotic measure called the design sensitivity, and by simulating power in finite samples. The three examples are drawn from epidemiology, clinical medicine, and genetic toxicology. © 2010, The International Biometric Society.

  7. Maximal near-field radiative heat transfer between two plates

    NASA Astrophysics Data System (ADS)

    Nefzaoui, Elyes; Ezzahri, Younès; Drévillon, Jérémie; Joulain, Karl

    2013-09-01

    Near-field radiative transfer is a promising way to significantly and simultaneously enhance both thermo-photovoltaic (TPV) devices power densities and efficiencies. A parametric study of Drude and Lorentz models performances in maximizing near-field radiative heat transfer between two semi-infinite planes separated by nanometric distances at room temperature is presented in this paper. Optimal parameters of these models that provide optical properties maximizing the radiative heat flux are reported and compared to real materials usually considered in similar studies, silicon carbide and heavily doped silicon in this case. Results are obtained by exact and approximate (in the extreme near-field regime and the electrostatic limit hypothesis) calculations. The two methods are compared in terms of accuracy and CPU resources consumption. Their differences are explained according to a mesoscopic description of nearfield radiative heat transfer. Finally, the frequently assumed hypothesis which states a maximal radiative heat transfer when the two semi-infinite planes are of identical materials is numerically confirmed. Its subsequent practical constraints are then discussed. Presented results enlighten relevant paths to follow in order to choose or design materials maximizing nano-TPV devices performances.

  8. Efficacy of Acupuncture versus Combined Oral Contraceptive Pill in Treatment of Moderate-to-Severe Dysmenorrhea: A Randomized Controlled Trial

    PubMed Central

    Sriprasert, Intira; Suerungruang, Suparerk; Athilarp, Porntip; Matanasarawoot, Anuchart

    2015-01-01

    This open-label randomized controlled trial was designed to compare the efficacy of acupuncture and combined oral contraceptive (COC) pill in treating moderate-to-severe primary dysmenorrhea. Fifty-two participants were randomly assigned to receive either acupuncture (n = 27) or COC (n = 25) for three menstrual cycles. Mefenamic acid was prescribed as a recue analgesic drug with both groups. The statistical approach used for efficacy and safety assessments was intention-to-treat analysis. By the end of the study, both treatments had resulted in significant improvement over baselines in all outcomes, that is, maximal dysmenorrhea pain scores, days suffering from dysmenorrhea, amount of rescue analgesic used, and quality of life assessed by SF-36 questionnaire. Over the three treatment cycles, COC caused greater reduction in maximal pain scores than acupuncture, while improvements in the remaining outcomes were comparable. Responders were defined as participants whose maximal dysmenorrhea pain scores decreased at least 33% below their baseline. Response rates following both interventions at the end of the study were not statistically different. Acupuncture commonly caused minimal local side effects but did not cause any hormone-related side effects as did COC. In conclusion, acupuncture is an alternative option for relieving dysmenorrhea, especially when COC is not a favorable choice. PMID:26346199

  9. Associations of maximal voluntary isometric hip extension torque with muscle size of hamstring and gluteus maximus and intra-abdominal pressure.

    PubMed

    Tayashiki, Kota; Hirata, Kosuke; Ishida, Kiraku; Kanehisa, Hiroaki; Miyamoto, Naokazu

    2017-06-01

    Muscle size of the hamstring and gluteus maximus (GM) as well as intra-abdominal pressure (IAP) are considered as factors affecting the torque development during hip extension. This study examined the associations of torque development during maximal voluntary isometric hip extension with IAP and muscle size of the hamstring and GM. Anatomical cross-sectional area (ACSA) of the hamstring and thickness of GM were determined in 20 healthy young males using an ultrasonography apparatus (Experiment 1). Torque and IAP were simultaneously measured while subjects performed maximal voluntary isometric hip extension. The IAP was measured using a pressure transducer placed in the rectum and determined at the time at which the developed torque reached to the maximal. In Experiment 2, torque and IAP were measured during maximal voluntary isometric hip flexion in 18 healthy young males. The maximal hip extension torque was significantly correlated with the IAP (r = 0.504, P = 0.024), not with the ACSA of the hamstring (r = 0.307, P = 0.188) or the thickness of GM (r = 0.405, P = 0.076). The relationship was still significant even when the ACSA of the hamstring and the thickness of GM were adjusted statistically (r = 0.486, P = 0.041). The maximal hip flexion torque was not significantly correlated with the IAP (r = -0.118, P = 0.642). The current results suggest that IAP can contribute independently of the muscle size of the agonists to maximal voluntary hip extension torque.

  10. [Acute physical exercise increases homocysteine concentrations in young trained male subjects].

    PubMed

    Maroto-Sánchez, Beatriz; Valtueña, Jara; Albers, Ulrike; Benito, Pedro J; González-Gross, Marcela

    2013-01-01

    High levels of homocysteine (Hcy) have been identified as a cardiovascular risk factor. Regarding physical exercise, the results are contradictory. The aim of this study was to determine the influence of maximal intensity exercise and submaximal constant exercise on total serum homocysteine concentrations (tHcy) and other related parameters. Ten physically active male subjects (mean age: 23.51 ± 1.84), performed two treadmill tests, a maximal test and a stable submaximal test at an intensity of 65% of maximal oxygen uptake (VO2max). Serum concentrations of tHcy, Folate, Vitamin B12 and creatinine were analysed before and after each test. Significant increase in serum tHcy concentrations after the maximal (p < 0.05) and submaximal (p < 0.01) tests were observed. Folate and vitamin B12 concentrations also increased significantly after both tests (p < 0.05). Creatinine levels increased only after the maximal test (p < 0.001). A statistically significant inverse relationship was found between folate and tHcy concentrations (p < 0.05) at all the measurement points. THcy levels increased significantly after acute exercise in both maximum and submaximal intensity exercises. Copyright © AULA MEDICA EDICIONES 2013. Published by AULA MEDICA. All rights reserved.

  11. The reliability and validity of fatigue measures during short-duration maximal-intensity intermittent cycling.

    PubMed

    Glaister, Mark; Stone, Michael H; Stewart, Andrew M; Hughes, Michael; Moir, Gavin L

    2004-08-01

    The purpose of the present study was to assess the reliability and validity of fatigue measures, as derived from 4 separate formulae, during tests of repeat sprint ability. On separate days over a 3-week period, 2 groups of 7 recreationally active men completed 6 trials of 1 of 2 maximal (20 x 5 seconds) intermittent cycling tests with contrasting recovery periods (10 or 30 seconds). All trials were conducted on a friction-braked cycle ergometer, and fatigue scores were derived from measures of mean power output for each sprint. Apart from formula 1, which calculated fatigue from the percentage difference in mean power output between the first and last sprint, all remaining formulae produced fatigue scores that showed a reasonably good level of test-retest reliability in both intermittent test protocols (intraclass correlation range: 0.78-0.86; 95% likely range of true values: 0.54-0.97). Although between-protocol differences in the magnitude of the fatigue scores suggested good construct validity, within-protocol differences highlighted limitations with each formula. Overall, the results support the use of the percentage decrement score as the most valid and reliable measure of fatigue during brief maximal intermittent work.

  12. Maximizing tandem solar cell power extraction using a three-terminal design

    DOE PAGES

    Warren, Emily L.; Deceglie, Michael G.; Rienacker, Michael; ...

    2018-04-09

    Three-terminal tandem solar cells can provide a robust operating mechanism to efficiently capture the solar spectrum without the need to current match sub-cells or fabricate complicated metal interconnects.

  13. Maximizing tandem solar cell power extraction using a three-terminal design

    DOE PAGES

    Warren, Emily L.; Deceglie, Michael G.; Rienäcker, Michael; ...

    2018-01-01

    Three-terminal tandem solar cells can provide a robust operating mechanism to efficiently capture the solar spectrum without the need to current match sub-cells or fabricate complicated metal interconnects.

  14. Associations between cardiorespiratory responses to exercise and the C34T AMPD1 gene polymorphism in the HERITAGE Family Study.

    PubMed

    Rico-Sanz, J; Rankinen, T; Joanisse, D R; Leon, A S; Skinner, J S; Wilmore, J H; Rao, D C; Bouchard, C

    2003-07-07

    The associations of the C34T polymorphism of the adenosine monophosphate deaminase 1 (AMPD1) gene with cardiorespiratory phenotypes were tested during cycling exercise at absolute and relative power outputs progressing to exhaustion before and after endurance training for 20 wk in the HERITAGE Family Study cohort (n = 779). Since no blacks were mutant homozygotes (TT), only whites were considered for analysis (400 normal homozygotes, CC; 97 heterozygotes, CT; and 6 TT). For sedentary state, cycling at the absolute power output of 50 W resulted in a higher rating of perceived exertion in TT (P < 0.0001). At the relative intensity of 60% of Vo(2 max), stroke volume was lower in TT (P < 0.05). Maximal values for power output, systolic blood pressure, heart rate, Vco(2), and respiratory exchange ratio were lower in TT (P < 0.05). The cardiorespiratory training response at 50 W and at 60% of Vo(2 max) was similar across C34T-AMPD1 genotypes. However, the maximal values for ventilation, Vo(2), and Vco(2) during exercise increased less in TT (P < 0.01). The results indicate that subjects with the TT genotype at the C34T AMPD1 gene have diminished exercise capacity and cardiorespiratory responses to exercise in the sedentary state. Furthermore, the training response of ventilatory phenotypes during maximal exercise is more limited in TT.

  15. Re-Form: FPGA-Powered True Codesign Flow for High-Performance Computing In The Post-Moore Era

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cappello, Franck; Yoshii, Kazutomo; Finkel, Hal

    Multicore scaling will end soon because of practical power limits. Dark silicon is becoming a major issue even more than the end of Moore’s law. In the post-Moore era, the energy efficiency of computing will be a major concern. FPGAs could be a key to maximizing the energy efficiency. In this paper we address severe challenges in the adoption of FPGA in HPC and describe “Re-form,” an FPGA-powered codesign flow.

  16. Proceedings of the Annual Conference on Ada (Trademark) Technology (2nd) Held at Hampton, Virginia on March 27, 28, 1984.

    DTIC Science & Technology

    1984-03-01

    evaluation of powerful support environments are essential if we are to maximize Lanauage Definition the productivity of programmers. CENVTACS provided...quality Policy and Objectives Ada support environment which includes a rich set of powerful tools (in addition to a compiler) The DOD has established Ada...to be easy to learn and easy to use. It will be powerful , efficient, and The MAPSE Command Language (MCL) friendly. This paper describes how these

  17. High-Density Signal Interface Electromagnetic Radiation Prediction for Electromagnetic Compatibility Evaluation.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Halligan, Matthew

    Radiated power calculation approaches for practical scenarios of incomplete high- density interface characterization information and incomplete incident power information are presented. The suggested approaches build upon a method that characterizes power losses through the definition of power loss constant matrices. Potential radiated power estimates include using total power loss information, partial radiated power loss information, worst case analysis, and statistical bounding analysis. A method is also proposed to calculate radiated power when incident power information is not fully known for non-periodic signals at the interface. Incident data signals are modeled from a two-state Markov chain where bit state probabilities aremore » derived. The total spectrum for windowed signals is postulated as the superposition of spectra from individual pulses in a data sequence. Statistical bounding methods are proposed as a basis for the radiated power calculation due to the statistical calculation complexity to find a radiated power probability density function.« less

  18. Recovery Responses to Maximal Exercise in Healthy-Weight Children and Children With Obesity.

    PubMed

    Easley, Elizabeth A; Black, W Scott; Bailey, Alison L; Lennie, Terry A; Sims, Wilma J; Clasey, Jody L

    2018-03-01

    The purpose of this study was to examine differences in heart rate recovery (HRRec) and oxygen consumption recovery (VO 2 recovery) between young healthy-weight children and children with obesity following a maximal volitional graded exercise test (GXTmax). Twenty healthy-weight children and 13 children with obesity completed body composition testing and performed a GXTmax. Immediately after the GXTmax, HRRec and VO 2 recovery were measured each minute for 5 consecutive minutes. There were no statistically significant group differences in HRRec for the 5 min following maximal exercise, Wilks's Lambda = .885, F(4, 28) = 0.911, p = .471, between the healthy-weight children and children with obesity despite statistically significant differences in body fat percentage (BF%; healthy-weight children, 18.5 ± 6.1%; children with obesity, 41.1 ± 6.9%, p < .001) and aerobic capacity relative to body mass (VO 2 peak; healthy-weight children, 46.8 ± 8.2 mL/kg/min; children with obesity, 31.9 ± 4.7 mL/kg/min, p < .001). There were statistically significant differences in VO 2 recovery for the 5 min following exercise, Wilks's Lambda = .676, F(4, 26) = 3.117, p = .032. There were no statistically significant correlations between HRRec and body mass index (BMI), BF%, VO 2 peak, or physical activity. In a healthy pediatric population, obesity alone does not seem to significantly impact HRRec, and because HRRec was not related to obesity status, BMI, or BF%, it should not be used as the sole indicator of aerobic capacity or health status in children. Using more than one recovery variable (i.e., HRRec and VO 2 recovery) may provide greater insight into cardiorespiratory fitness in this population.

  19. Relative risk estimates from spatial and space-time scan statistics: Are they biased?

    PubMed Central

    Prates, Marcos O.; Kulldorff, Martin; Assunção, Renato M.

    2014-01-01

    The purely spatial and space-time scan statistics have been successfully used by many scientists to detect and evaluate geographical disease clusters. Although the scan statistic has high power in correctly identifying a cluster, no study has considered the estimates of the cluster relative risk in the detected cluster. In this paper we evaluate whether there is any bias on these estimated relative risks. Intuitively, one may expect that the estimated relative risks has upward bias, since the scan statistic cherry picks high rate areas to include in the cluster. We show that this intuition is correct for clusters with low statistical power, but with medium to high power the bias becomes negligible. The same behaviour is not observed for the prospective space-time scan statistic, where there is an increasing conservative downward bias of the relative risk as the power to detect the cluster increases. PMID:24639031

  20. Statistical analysis of the factors that influenced the mechanical properties improvement of cassava starch films

    NASA Astrophysics Data System (ADS)

    Monteiro, Mayra; Oliveira, Victor; Santos, Francisco; Barros Neto, Eduardo; Silva, Karyn; Silva, Rayane; Henrique, João; Chibério, Abimaelle

    2017-08-01

    In order to obtain cassava starch films with improved mechanical properties in relation to the synthetic polymer in the packaging production, a complete factorial design 23 was carried out in order to investigate which factor significantly influences the tensile strength of the biofilm. The factors to be investigated were cassava starch, glycerol and modified clay contents. Modified bentonite clay was used as a filling material of the biofilm. Glycerol was the plasticizer used to thermoplastify cassava starch. The factorial analysis suggested a regression model capable of predicting the optimal mechanical property of the cassava starch film from the maximization of the tensile strength. The reliability of the regression model was tested by the correlation established with the experimental data through the following statistical analyse: Pareto graph. The modified clay was the factor of greater statistical significance on the observed response variable, being the factor that contributed most to the improvement of the mechanical property of the starch film. The factorial experiments showed that the interaction of glycerol with both modified clay and cassava starch was significant for the reduction of biofilm ductility. Modified clay and cassava starch contributed to the maximization of biofilm ductility, while glycerol contributed to the minimization.

Top