Metoki, Hirohito; Ohkubo, Takayoshi; Kikuya, Masahiro; Asayama, Kei; Inoue, Ryusuke; Obara, Taku; Hirose, Takuo; Sato, Michihiro; Hashimoto, Takanao; Imai, Yutaka
2012-07-01
The hypotensive effect and the time to attain the maximum antihypertensive effect (stabilization time) of losartan/hydrochlorothiazide (HCTZ) combination therapy and therapy with a maximal dose of angiotensin II receptor blockers (ARBs) in patients who failed to achieve adequate blood pressure (BP) control on a medium-dose of ARBs were compared by analyzing exponential decay functions using daily serial morning home BP measurements. Essential hypertensive patients treated with a medium dose of ARB, in whom a target home SBP (135 mmHg) was not achieved, were randomized into two groups: a combination group (n = 110) and a maximal-dose ARB group (n = 111). The combination therapy provided additional reduction of 5.2 mmHg [95% confidence interval (CI) 1.8 to 8.5 mmHg, P = 0.003] in home SBP over the maximal-dose ARB therapy in 8 weeks after randomization. A greater reduction in the home SBP values was seen in the combination group than in the maximal-dose ARB group from the second day after randomization on the basis of a linear mixed model. The maximum antihypertensive effect and stabilization time for home SBP were 10.9 ± 5.0 mmHg and 7.3 ± 29.7 days, respectively, in the combination group, whereas the corresponding values in the maximal-dose ARB group were 7.9 ± 2.6 mmHg and 122.3 ± 42.7 days, respectively, on the basis of a nonlinear mixed model. Changing from a medium dose of ARB monotherapy to combination therapy was more effective in the reduction of home SBP and achieved goal BP more rapidly than increasing the ARB dose. Home BP measurement is a useful tool for characterizing the antihypertensive effects of drugs.
Prenatal and postnatal toxicity induced in guinea-pigs by nitrosomethylurea.
Epstein, S S; Hasumi, K; Iobal, Z M
1976-01-01
Oral administration of NMU at maximally tolerated doses of guinea-pigs from day 34 to 58 of pregnancy induced embryotoxic effects, as evidenced by a high incidence of stillbirths and reduction in birth weight, and postnatal toxic effects, as evidenced by stunting, progressive mortality and extensive fatty degeneration of the liver in F1 progeny. Similar administration of NMUT at maximally tolerated doses did not induce such toxic effects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghadjar, Pirus; Zelefsky, Michael J.; Spratt, Daniel E.
2014-02-01
Purpose: To determine the potential association between genitourinary (GU) toxicity and planning dose–volume parameters for GU pelvic structures after high-dose intensity modulated radiation therapy in localized prostate cancer patients. Methods and Materials: A total of 268 patients who underwent intensity modulated radiation therapy to a prescribed dose of 86.4 Gy in 48 fractions during June 2004-December 2008 were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Dose–volume histograms of the whole bladder, bladder wall, urethra, and bladder trigone were analyzed. The primary endpoint for GU toxicity was an IPSS sum increase ≥10 points over baseline. Univariate and multivariate analysesmore » were done by the Kaplan-Meier method and Cox proportional hazard models, respectively. Results: Median follow-up was 5 years (range, 3-7.7 years). Thirty-nine patients experienced an IPSS sum increase ≥10 during follow-up; 84% remained event free at 5 years. After univariate analysis, lower baseline IPSS sum (P=.006), the V90 of the trigone (P=.006), and the maximal dose to the trigone (P=.003) were significantly associated with an IPSS sum increase ≥10. After multivariate analysis, lower baseline IPSS sum (P=.009) and increased maximal dose to the trigone (P=.005) remained significantly associated. Seventy-two patients had both a lower baseline IPSS sum and a higher maximal dose to the trigone and were defined as high risk, and 68 patients had both a higher baseline IPSS sum and a lower maximal dose to the trigone and were defined as low risk for development of an IPSS sum increase ≥10. Twenty-one of 72 high-risk patients (29%) and 5 of 68 low-risk patients (7%) experienced an IPSS sum increase ≥10 (P=.001; odds ratio 5.19). Conclusions: The application of hot spots to the bladder trigone was significantly associated with relevant changes in IPSS during follow-up. Reduction of radiation dose to the lower bladder and specifically the bladder trigone seems to be associated with a reduction in late GU toxicity.« less
Cryoradiolytic reduction of heme proteins: Maximizing dose-dependent yield
NASA Astrophysics Data System (ADS)
Denisov, Ilia G.; Victoria, Doreen C.; Sligar, Stephen G.
2007-04-01
Radiolytic reduction in frozen solutions and crystals is a useful method for generation of trapped intermediates in protein-based radical reactions. In this communication we define the conditions which provide the maximum yield of one electron-reduced myoglobin at 77 K using 60Co γ-irradiation in aqueous glycerol glass. The yield reached 50% after 20 kGy, was almost complete at ˜160 kGy total dose, and does not depend on the protein concentration in the range 0.01-5 mM.
Bousquet, J; Hejjaoui, A; Soussana, M; Michel, F B
1990-02-01
Specific immunotherapy is still widely used in grass-pollen allergy, but its side effects may limit its use. We tested the safety and efficacy of a formalinized high-molecular-weight allergoid prepared from a mixed grass-pollen extract with two injection schedules in a double-blind, placebo-controlled study. Eighteen patients received placebo, 19 received the low-dose schedule (maximal dose: 2000 PNU) and 20 received the high-dose schedule (maximal dose: 10,000 PNU). Only one patient presented a systemic reaction of moderate severity for a dose of 1200 PNU. Before the onset of the pollen season, patients had a nasal challenge with orchard grass-pollen grains, a skin test titration, and the titration of serum-specific IgG. Both groups of patients presented a significant reduction in nasal and skin sensitivities and a significant increase in IgG compared to placebo. Symptoms and medications for rhinitis and asthma were studied during the season, and both groups receiving allergoids had a significant reduction of symptom-medication scores for nasal and bronchial symptoms. There was a highly significant correlation between nasal symptom-medication scores during the season and the results of nasal challenges. High-molecular-weight allergoids are safe and effective.
Vardeny, Orly; Claggett, Brian; Packer, Milton; Zile, Michael R; Rouleau, Jean; Swedberg, Karl; Teerlink, John R; Desai, Akshay S; Lefkowitz, Martin; Shi, Victor; McMurray, John J V; Solomon, Scott D
2016-10-01
In this analysis, we utilized data from PARADIGM-HF to test the hypothesis that participants who exhibited any dose reduction during the trial would have similar benefits from lower doses of sacubitril/valsartan relative to lower doses of enalapril. In a post-hoc analysis from PARADIGM-HF, we characterized patients by whether they received the maximal dose (200 mg sacubitril/valsartan or 10 mg enalapril twice daily) throughout the trial or had any dose reduction to lower doses (100/50/0 mg sacubitril/valsartan or 5/2.5/0 mg enalapril twice daily). The treatment effect for the primary outcome was estimated, stratified by dose level using time-updated Cox regression models. In the two treatment arms, participants with a dose reduction (43% of those randomized to enalapril and 42% of those randomized to sacubitril/valsartan) had similar baseline characteristics and similar baseline predictors of the need for dose reduction. In a time-updated analysis, any dose reduction was associated with a higher subsequent risk of the primary event [hazard ratio (HR) 2.5, 95% confidence interval (CI) 2.2-2.7]. However, the treatment benefit of sacubitril/valsartan over enalapril following a dose reduction was similar (HR 0.80, 95% CI 0.70-0.93, P < 0.001) to that observed in patients who had not experienced any dose reduction (HR 0.79, 95% CI 0.71-0.88, P < 0.001). In PARADIGM-HF, study medication dose reduction identified patients at higher risk of a major cardiovascular event. The magnitude of benefit for patients on lower doses of sacubitril/valsartan relative to those on lower doses of enalapril was similar to that of patients who remained on target doses of both drugs. © 2016 The Authors. European Journal of Heart Failure published by John Wiley & Sons Ltd on behalf of European Society of Cardiology.
Kim, Hyun Gi; Lee, Young Han; Choi, Jin-Young; Park, Mi-Suk; Kim, Myeong-Jin; Kim, Ki Whang
2015-01-01
Purpose To investigate the optimal blending percentage of adaptive statistical iterative reconstruction (ASIR) in a reduced radiation dose while preserving a degree of image quality and texture that is similar to that of standard-dose computed tomography (CT). Materials and Methods The CT performance phantom was scanned with standard and dose reduction protocols including reduced mAs or kVp. Image quality parameters including noise, spatial, and low-contrast resolution, as well as image texture, were quantitatively evaluated after applying various blending percentages of ASIR. The optimal blending percentage of ASIR that preserved image quality and texture compared to standard dose CT was investigated in each radiation dose reduction protocol. Results As the percentage of ASIR increased, noise and spatial-resolution decreased, whereas low-contrast resolution increased. In the texture analysis, an increasing percentage of ASIR resulted in an increase of angular second moment, inverse difference moment, and correlation and in a decrease of contrast and entropy. The 20% and 40% dose reduction protocols with 20% and 40% ASIR blending, respectively, resulted in an optimal quality of images with preservation of the image texture. Conclusion Blending the 40% ASIR to the 40% reduced tube-current product can maximize radiation dose reduction and preserve adequate image quality and texture. PMID:25510772
Yang, Danlin; Giragossian, Craig; Castellano, Steven; Lasaro, Marcio; Xiao, Haiguang; Saraf, Himanshu; Hess Kenny, Cynthia; Rybina, Irina; Huang, Zhong-Fu; Ahlberg, Jennifer; Bigwarfe, Tammy; Myzithras, Maria; Waltz, Erica; Roberts, Simon; Kroe-Barrett, Rachel; Singh, Sanjaya
2017-10-01
Antibodies with pH-dependent binding to both target antigens and neonatal Fc receptor (FcRn) provide an alternative tool to conventional neutralizing antibodies, particularly for therapies where reduction in antigen level is challenging due to high target burden. However, the requirements for optimal binding kinetic framework and extent of pH dependence for these antibodies to maximize target clearance from circulation are not well understood. We have identified a series of naturally-occurring high affinity antibodies with pH-dependent target binding properties. By in vivo studies in cynomolgus monkeys, we show that pH-dependent binding to the target alone is not sufficient for effective target removal from circulation, but requires Fc mutations that increase antibody binding to FcRn. Affinity-enhanced pH-dependent FcRn binding that is double-digit nM at pH 7.4 and single-digit nM at pH 6 achieved maximal target reduction when combined with similar target binding affinities in reverse pH directions. Sustained target clearance below the baseline level was achieved 3 weeks after single-dose administration at 1.5 mg/kg. Using the experimentally derived mechanistic model, we demonstrate the essential kinetic interplay between target turnover and antibody pH-dependent binding during the FcRn recycling, and identify the key components for achieving maximal target clearance. These results bridge the demand for improved patient dosing convenience with the "know-how" of therapeutic modality by design.
Pan, Lin; Schaefer, Caralee; Nicholas, John; Lim, Sharlene; Misialek, Shawn; Stevens, Sarah; Hooi, Lisa; Aleskovski, Natalia; Ruhrmund, Donald; Kossen, Karl; Huang, Lea; Yap, Sophia; Beigelman, Leonid; Serebryany, Vladimir; Liu, Jyanwei; Sastry, Srikonda; Seiwert, Scott; Buckman, Brad
2016-01-01
Abstract The current paradigm for the treatment of chronic hepatitis C virus (HCV) infection involves combinations of agents that act directly on steps of the HCV life cycle. Here we report the preclinical characteristics of ITMN-8187, a nonmacrocyclic inhibitor of the NS3/4A HCV protease. X-ray crystallographic studies of ITMN-8187 and simeprevir binding to NS3/4A protease demonstrated good agreement between structures. Low nanomolar biochemical potency was maintained against NS3/4A derived from HCV genotypes 1, 2b, 4, 5, and 6. In cell-based potency assays, half-maximal reduction of genotype 1a and 1b HCV replicon RNA was afforded by 11 and 4 nM doses of ITMN-8187, respectively. Combinations of ITMN-8187 with other directly acting antiviral agents in vitro displayed additive antiviral efficacy. A 30-mg/kg of body weight dose of ITMN-8187 administered for 4 days yielded significant viral load reductions through day 5 in a chimeric mouse model of HCV. A 3-mg/kg oral dose administered to rats, dogs, or monkeys yielded concentrations in plasma 16 h after dosing that exceeded the half-maximal effective concentration of ITMN-8187. Human microdose pharmacokinetics showed low intersubject variability and prolonged oral absorption with first-order elimination kinetics compatible with once-daily dosing. These preclinical characteristics compare favorably with those of other NS3/4A inhibitors approved for the treatment of chronic HCV infection. PMID:27795376
Vestibulo-ocular reflexes in rabbits: reduction by intravenous injection of diazepam.
Barmack, N H; Pettorossi, V E
1980-11-01
We have studied the influence of intravenously administered diazepam on the horizontal (HVOR) and vertical (VVOR) vestibulo-ocular reflexes of the rabbit. The HVOR and VVOR were evoked by sinusoidal oscillation of rabbits on a rate table (0.01 to 0.8 Hz, +/- 10 degrees), and eye movements were measured with an infrared light-projection technique. The gains of the HVOR and VVOR (evoked eye velocity/head velocity) were reduced by diazepam injections of 5 microgram/kg. The dose required to produce a 50% reduction in HVOR gain was 500 microgram/kg. The time required to reduce the HVOR gain to 50% of its maximal reduction at dose of 400 microgram/kg (0.4 Hz +/- 10 degrees) was 60 s. These data suggest that diazepam might be effective as an anti-motion-sickness agent.
Rajagopalan, Ravi; Pan, Lin; Schaefer, Caralee; Nicholas, John; Lim, Sharlene; Misialek, Shawn; Stevens, Sarah; Hooi, Lisa; Aleskovski, Natalia; Ruhrmund, Donald; Kossen, Karl; Huang, Lea; Yap, Sophia; Beigelman, Leonid; Serebryany, Vladimir; Liu, Jyanwei; Sastry, Srikonda; Seiwert, Scott; Buckman, Brad
2017-01-01
The current paradigm for the treatment of chronic hepatitis C virus (HCV) infection involves combinations of agents that act directly on steps of the HCV life cycle. Here we report the preclinical characteristics of ITMN-8187, a nonmacrocyclic inhibitor of the NS3/4A HCV protease. X-ray crystallographic studies of ITMN-8187 and simeprevir binding to NS3/4A protease demonstrated good agreement between structures. Low nanomolar biochemical potency was maintained against NS3/4A derived from HCV genotypes 1, 2b, 4, 5, and 6. In cell-based potency assays, half-maximal reduction of genotype 1a and 1b HCV replicon RNA was afforded by 11 and 4 nM doses of ITMN-8187, respectively. Combinations of ITMN-8187 with other directly acting antiviral agents in vitro displayed additive antiviral efficacy. A 30-mg/kg of body weight dose of ITMN-8187 administered for 4 days yielded significant viral load reductions through day 5 in a chimeric mouse model of HCV. A 3-mg/kg oral dose administered to rats, dogs, or monkeys yielded concentrations in plasma 16 h after dosing that exceeded the half-maximal effective concentration of ITMN-8187. Human microdose pharmacokinetics showed low intersubject variability and prolonged oral absorption with first-order elimination kinetics compatible with once-daily dosing. These preclinical characteristics compare favorably with those of other NS3/4A inhibitors approved for the treatment of chronic HCV infection. Copyright © 2016 American Society for Microbiology.
Implementation of dual-energy technique for virtual monochromatic and linearly mixed CBCTs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li Hao; Giles, William; Ren Lei
Purpose: To implement dual-energy imaging technique for virtual monochromatic (VM) and linearly mixed (LM) cone beam CTs (CBCTs) and to demonstrate their potential applications in metal artifact reduction and contrast enhancement in image-guided radiation therapy (IGRT). Methods: A bench-top CBCT system was used to acquire 80 kVp and 150 kVp projections, with an additional 0.8 mm tin filtration. To implement the VM technique, these projections were first decomposed into acrylic and aluminum basis material projections to synthesize VM projections, which were then used to reconstruct VM CBCTs. The effect of VM CBCT on the metal artifact reduction was evaluated withmore » an in-house titanium-BB phantom. The optimal VM energy to maximize contrast-to-noise ratio (CNR) for iodine contrast and minimize beam hardening in VM CBCT was determined using a water phantom containing two iodine concentrations. The LM technique was implemented by linearly combining the low-energy (80 kVp) and high-energy (150 kVp) CBCTs. The dose partitioning between low-energy and high-energy CBCTs was varied (20%, 40%, 60%, and 80% for low-energy) while keeping total dose approximately equal to single-energy CBCTs, measured using an ion chamber. Noise levels and CNRs for four tissue types were investigated for dual-energy LM CBCTs in comparison with single-energy CBCTs at 80, 100, 125, and 150 kVp. Results: The VM technique showed substantial reduction of metal artifacts at 100 keV with a 40% reduction in the background standard deviation compared to a 125 kVp single-energy scan of equal dose. The VM energy to maximize CNR for both iodine concentrations and minimize beam hardening in the metal-free object was 50 keV and 60 keV, respectively. The difference of average noise levels measured in the phantom background was 1.2% between dual-energy LM CBCTs and equivalent-dose single-energy CBCTs. CNR values in the LM CBCTs of any dose partitioning are better than those of 150 kVp single-energy CBCTs. The average CNR for four tissue types with 80% dose fraction at low-energy showed 9.0% and 4.1% improvement relative to 100 kVp and 125 kVp single-energy CBCTs, respectively. CNRs for low-contrast objects improved as dose partitioning was more heavily weighted toward low-energy (80 kVp) for LM CBCTs. Conclusions: Dual-energy CBCT imaging techniques were implemented to synthesize VM CBCT and LM CBCTs. VM CBCT was effective at achieving metal artifact reduction. Depending on the dose-partitioning scheme, LM CBCT demonstrated the potential to improve CNR for low contrast objects compared to single-energy CBCT acquired with equivalent dose.« less
Brady, Samuel L; Moore, Bria M; Yee, Brian S; Kaufman, Robert A
2014-01-01
To determine a comprehensive method for the implementation of adaptive statistical iterative reconstruction (ASIR) for maximal radiation dose reduction in pediatric computed tomography (CT) without changing the magnitude of noise in the reconstructed image or the contrast-to-noise ratio (CNR) in the patient. The institutional review board waived the need to obtain informed consent for this HIPAA-compliant quality analysis. Chest and abdominopelvic CT images obtained before ASIR implementation (183 patient examinations; mean patient age, 8.8 years ± 6.2 [standard deviation]; range, 1 month to 27 years) were analyzed for image noise and CNR. These measurements were used in conjunction with noise models derived from anthropomorphic phantoms to establish new beam current-modulated CT parameters to implement 40% ASIR at 120 and 100 kVp without changing noise texture or magnitude. Image noise was assessed in images obtained after ASIR implementation (492 patient examinations; mean patient age, 7.6 years ± 5.4; range, 2 months to 28 years) the same way it was assessed in the pre-ASIR analysis. Dose reduction was determined by comparing size-specific dose estimates in the pre- and post-ASIR patient cohorts. Data were analyzed with paired t tests. With 40% ASIR implementation, the average relative dose reduction for chest CT was 39% (2.7/4.4 mGy), with a maximum reduction of 72% (5.3/18.8 mGy). The average relative dose reduction for abdominopelvic CT was 29% (4.8/6.8 mGy), with a maximum reduction of 64% (7.6/20.9 mGy). Beam current modulation was unnecessary for patients weighing 40 kg or less. The difference between 0% and 40% ASIR noise magnitude was less than 1 HU, with statistically nonsignificant increases in patient CNR at 100 kVp of 8% (15.3/14.2; P = .41) for chest CT and 13% (7.8/6.8; P = .40) for abdominopelvic CT. Radiation dose reduction at pediatric CT was achieved when 40% ASIR was implemented as a dose reduction tool only; no net change to the magnitude of noise in the reconstructed image or the patient CNR occurred. © RSNA, 2013.
Tetenev, F F; Cherniavskaia, G M
1989-01-01
A study was made of the action of inhalation of a single atrovent dose in 20 patients with chronic obstructive bronchitis. All the patients demonstrated a considerable abatement or disappearance of dyspnea, and a reduction of the number of dry rales. The vital capacity of the lungs, the volume of forced expiration, maximal pulmonary ventilation, MOCmax, MOC50, and MOC75 substantially increased. The respiratory work diminished on the average by 32.3% primarily due to the lessening of non-elastic lung resistance. The rise of pulmonary static extensibility and reduction of pulmonary elastic propulsion were recorded. In patients with and without clinical signs of bronchospasm, the action of atrovent was identical.
Mirro, Amy E.; Brady, Samuel L.; Kaufman, Robert. A.
2016-01-01
Purpose To implement the maximum level of statistical iterative reconstruction that can be used to establish dose-reduced head CT protocols in a primarily pediatric population. Methods Select head examinations (brain, orbits, sinus, maxilla and temporal bones) were investigated. Dose-reduced head protocols using an adaptive statistical iterative reconstruction (ASiR) were compared for image quality with the original filtered back projection (FBP) reconstructed protocols in phantom using the following metrics: image noise frequency (change in perceived appearance of noise texture), image noise magnitude, contrast-to-noise ratio (CNR), and spatial resolution. Dose reduction estimates were based on computed tomography dose index (CTDIvol) values. Patient CTDIvol and image noise magnitude were assessed in 737 pre and post dose reduced examinations. Results Image noise texture was acceptable up to 60% ASiR for Soft reconstruction kernel (at both 100 and 120 kVp), and up to 40% ASiR for Standard reconstruction kernel. Implementation of 40% and 60% ASiR led to an average reduction in CTDIvol of 43% for brain, 41% for orbits, 30% maxilla, 43% for sinus, and 42% for temporal bone protocols for patients between 1 month and 26 years, while maintaining an average noise magnitude difference of 0.1% (range: −3% to 5%), improving CNR of low contrast soft tissue targets, and improving spatial resolution of high contrast bony anatomy, as compared to FBP. Conclusion The methodology in this study demonstrates a methodology for maximizing patient dose reduction and maintaining image quality using statistical iterative reconstruction for a primarily pediatric population undergoing head CT examination. PMID:27056425
SU-C-12A-07: Effect of Vertical Position On Dose Reduction Using X-Care
DOE Office of Scientific and Technical Information (OSTI.GOV)
Silosky, M; Marsh, R
Purpose: Reduction of absorbed dose to radiosensitive tissues is an important goal in diagnostic radiology. Siemens Medical has introduced a technique (X-CARE) to lower CT dose to anterior anatomy by reducing the tube current during 80° of rotation over radiosensitive tissues. Phantom studies have shown 30-40% dose reduction when phantoms are positioned at isocenter. However, for CT face and sinus exams, the center of the head is commonly positioned below isocenter. This work investigated the effects of vertical patient positioning on dose reduction using X-CARE. Methods: A 16cm Computed Tomography Dose Index phantom was scanned on a Siemens Definition Flashmore » CT scanner using a routine head protocol, with the phantom positioned at scanner isocenter. Optically stimulated luminescent dosimeters were placed on the anterior and posterior sides of the phantom. The phantom was lowered in increments of 2cm and rescanned, up to 8cm below isocenter. The experiment was then repeated using the same scan parameters but adding the X-CARE technique. The mean dosimeter counts were determined for each phantom position, and the difference between XCARE and routine scans was plotted as a function of distance from isocenter. Results: With the phantom positioned at isocenter, using XCARE reduced dose to the anterior side of the phantom by 40%, compared to dose when X-CARE was not used. Positioned below isocenter, anterior dose was reduced by only 20-27%. Additionally, using X-CARE at isocenter reduced dose to the anterior portion of the phantom by 45.6% compared to scans performed without X-CARE 8cm below isocenter. Conclusion: While using X-CARE substantially reduced dose to the anterior side of the phantom, this effect was diminished when the phantom was positioned below isocenter, simulating common practice for face and sinus scans. This indicates that centering the head in the gantry will maximize the effect of X-CARE.« less
Brady, Samuel L.; Moore, Bria M.; Yee, Brian S.; Kaufman, Robert A.
2015-01-01
Purpose To determine a comprehensive method for the implementation of adaptive statistical iterative reconstruction (ASIR) for maximal radiation dose reduction in pediatric computed tomography (CT) without changing the magnitude of noise in the reconstructed image or the contrast-to-noise ratio (CNR) in the patient. Materials and Methods The institutional review board waived the need to obtain informed consent for this HIPAA-compliant quality analysis. Chest and abdominopelvic CT images obtained before ASIR implementation (183 patient examinations; mean patient age, 8.8 years ± 6.2 [standard deviation]; range, 1 month to 27 years) were analyzed for image noise and CNR. These measurements were used in conjunction with noise models derived from anthropomorphic phantoms to establish new beam current–modulated CT parameters to implement 40% ASIR at 120 and 100 kVp without changing noise texture or magnitude. Image noise was assessed in images obtained after ASIR implementation (492 patient examinations; mean patient age, 7.6 years ± 5.4; range, 2 months to 28 years) the same way it was assessed in the pre-ASIR analysis. Dose reduction was determined by comparing size-specific dose estimates in the pre- and post-ASIR patient cohorts. Data were analyzed with paired t tests. Results With 40% ASIR implementation, the average relative dose reduction for chest CT was 39% (2.7/4.4 mGy), with a maximum reduction of 72% (5.3/18.8 mGy). The average relative dose reduction for abdominopelvic CT was 29% (4.8/6.8 mGy), with a maximum reduction of 64% (7.6/20.9 mGy). Beam current modulation was unnecessary for patients weighing 40 kg or less. The difference between 0% and 40% ASIR noise magnitude was less than 1 HU, with statistically nonsignificant increases in patient CNR at 100 kVp of 8% (15.3/14.2; P = .41) for chest CT and 13% (7.8/6.8; P = .40) for abdominopelvic CT. Conclusion Radiation dose reduction at pediatric CT was achieved when 40% ASIR was implemented as a dose reduction tool only; no net change to the magnitude of noise in the reconstructed image or the patient CNR occurred. PMID:23901128
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jannik, T.; Karapatakis, D.; Lee, P.
2010-08-06
Operations at the Savannah River Site (SRS) result in releases of small amounts of radioactive materials to the atmosphere and to the Savannah River. For regulatory compliance purposes, potential offsite radiological doses are estimated annually using computer models that follow U.S. Nuclear Regulatory Commission (NRC) Regulatory Guides. Within the regulatory guides, default values are provided for many of the dose model parameters but the use of site-specific values by the applicant is encouraged. A detailed survey of land and water use parameters was conducted in 1991 and is being updated here. These parameters include local characteristics of meat, milk andmore » vegetable production; river recreational activities; and meat, milk and vegetable consumption rates as well as other human usage parameters required in the SRS dosimetry models. In addition, the preferred elemental bioaccumulation factors and transfer factors to be used in human health exposure calculations at SRS are documented. Based on comparisons to the 2009 SRS environmental compliance doses, the following effects are expected in future SRS compliance dose calculations: (1) Aquatic all-pathway maximally exposed individual doses may go up about 10 percent due to changes in the aquatic bioaccumulation factors; (2) Aquatic all-pathway collective doses may go up about 5 percent due to changes in the aquatic bioaccumulation factors that offset the reduction in average individual water consumption rates; (3) Irrigation pathway doses to the maximally exposed individual may go up about 40 percent due to increases in the element-specific transfer factors; (4) Irrigation pathway collective doses may go down about 50 percent due to changes in food productivity and production within the 50-mile radius of SRS; (5) Air pathway doses to the maximally exposed individual may go down about 10 percent due to the changes in food productivity in the SRS area and to the changes in element-specific transfer factors; and (6) Air pathway collective doses may go down about 30 percent mainly due to the decrease in the inhalation rate assumed for the average individual.« less
In vitro neurotoxic effects of 1 GeV/n iron particles assessed in retinal explants.
Vazquez, M E; Kirk, E
2000-01-01
The heavy ion component of the cosmic radiation remains problematic to the assessment of risk in manned space flight. The biological effectiveness of HZE particles has yet to be established, particularly with regard to nervous tissue. Using heavy ions accelerated at the AGS of Brookhaven National Laboratory, we study the neurotoxic effects of iron particles. We exposed retinal explants, taken from chick embryos, to determine the dose response relationships for neurite outgrowth. Morphometric techniques were used to evaluate the in vitro effects of 1 GeV/a iron particles (LET 148 keV/micrometer). Iron particles produced a dose-dependent reduction of neurite outgrowth with a maximal effect achieved with a dose of 100 cGy. Doses as low as 10-50 cGy were able to induce reductions of the neurite outgrowth as compared to the control group. Neurite generation is a more sensitive parameter than neurite elongation, suggesting different mechanism of radiation damage in our model. These results showed that low doses/fluences of iron particles could impair the retinal ganglion cells' capacity to generate neurites indicating the highly neurotoxic capability of this heavy charged particle.
Estimated ultraviolet radiation doses in wetlands in six national parks
Diamond, S.A.; Trenham, P.C.; Adams, Michael J.; Hossack, B.R.; Knapp, R.A.; Stark, L.; Bradford, D.; Corn, P.S.; Czarnowski, K.; Brooks, P.D.; Fagre, D.B.; Breen, B.; Dentenbeck, N.E.; Tonnessen, K.
2005-01-01
Ultraviolet-B radiation (UV-B, 280–320-nm wavelengths) doses were estimated for 1024 wetlands in six national parks: Acadia (Acadia), Glacier (Glacier), Great Smoky Mountains (Smoky), Olympic (Olympic), Rocky Mountain (Rocky), and Sequoia/Kings Canyon (Sequoia). Estimates were made using ground-based UV-B data (Brewer spectrophotometers), solar radiation models, GIS tools, field characterization of vegetative features, and quantification of DOC concentration and spectral absorbance. UV-B dose estimates were made for the summer solstice, at a depth of 1 cm in each wetland. The mean dose across all wetlands and parks was 19.3 W-h m−2 (range of 3.4–32.1 W-h m−2). The mean dose was lowest in Acadia (13.7 W-h m−2) and highest in Rocky (24.4 W-h m−2). Doses were significantly different among all parks. These wetland doses correspond to UV-B flux of 125.0 μW cm−2 (range 21.4–194.7 μW cm−2) based on a day length, averaged among all parks, of 15.5 h. Dissolved organic carbon (DOC), a key determinant of water-column UV-B flux, ranged from 0.6 (analytical detection limit) to 36.7 mg C L−1 over all wetlands and parks, and reduced potential maximal UV-B doses at 1-cm depth by 1%–87 %. DOC concentration, as well as its effect on dose, was lowest in Sequoia and highest in Acadia (DOC was equivalent in Acadia, Glacier, and Rocky). Landscape reduction of potential maximal UV-B doses ranged from zero to 77% and was lowest in Sequoia. These regional differences in UV-B wetland dose illustrate the importance of considering all aspects of exposure in evaluating the potential impact of UV-B on aquatic organisms.
Klonoff, David; Nayberg, Irina; Thonius, Marissa; See, Florian; Abdel-Tawab, Mona; Erbstein, Frank; Haak, Thomas
2015-08-26
To deliver insulin glargine 300 U/mL (Gla-300), the widely used SoloSTAR(®) pen has been modified to allow for accurate and precise delivery of required insulin units in one-third of the volume compared with insulin glargine 100 U/mL, while improving usability. Here we compare the accuracy and injection force of 3 disposable insulin pens: Gla-300 SoloSTAR(®), FlexPen(®), and KwikPen™. For the accuracy assessment, 60 of each of the 3 tested devices were used for the delivery of 3 different doses (1 U, half-maximal dose, and maximal dose), which were measured gravimetrically. For the injection force assessment, 20 pens of each of the 3 types were tested twice at half-maximal and once at maximal dose, at an injection speed of 6 U/s. All tested pens met the International Organization for Standardization (ISO) requirements for dosing accuracy, with Gla-300 SoloSTAR showing the lowest between-dose variation (greatest reproducibility) at all dose levels. Mean injection force was significantly lower for Gla-300 SoloSTAR than for the other 2 pens at both half maximal and maximal doses (P < .0271). All tested pens were accurate according to ISO criteria, and the Gla-300 SoloSTAR pen displayed the greatest reproducibility and lowest injection force of any of the 3 tested devices. © 2015 Diabetes Technology Society.
Silkosessak, O; Jacobs, R; Bogaerts, R; Bosmans, H; Panmekiate, S
2014-01-01
Objectives: To determine the optimal kVp setting for a particular cone beam CT (CBCT) device by maximizing technical image quality at a fixed radiation dose. Methods: The 3D Accuitomo 170 (J. Morita Mfg. Corp., Kyoto, Japan) CBCT was used. The radiation dose as a function of kVp was measured in a cylindrical polymethyl methacrylate (PMMA) phantom using a small-volume ion chamber. Contrast-to-noise ratio (CNR) was measured using a PMMA phantom containing four materials (air, aluminium, polytetrafluoroethylene and low-density polyethylene), which was scanned using 180 combinations of kVp/mA, ranging from 60/1 to 90/8. The CNR was measured for each material using PMMA as background material. The pure effect of kVp and mAs on the CNR values was analysed. Using a polynomial fit for CNR as a function of mA for each kVp value, the optimal kVp was determined at five dose levels. Results: Absorbed doses ranged between 0.034 mGy mAs−1 (14 × 10 cm, 60 kVp) and 0.108 mGy mAs−1 (14 × 10 cm, 90 kVp). The relation between kVp and dose was quasilinear (R2 > 0.99). The effect of mA and kVp on CNR could be modelled using a second-degree polynomial. At a fixed dose, there was a tendency for higher CNR values at increasing kVp values, especially at low dose levels. A dose reduction through mA was more efficient than an equivalent reduction through kVp in terms of image quality deterioration. Conclusions: For the investigated CBCT model, the most optimal contrast at a fixed dose was found at the highest available kVp setting. There is great potential for dose reduction through mA with a minimal loss in image quality. PMID:24708447
The Lateral Decubitus Breast Boost: Description, Rationale, and Efficacy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ludwig, Michelle S., E-mail: mludwig@mdanderson.or; McNeese, Marsha D.; Buchholz, Thomas A.
2010-01-15
Purpose: To describe and evaluate the modified lateral decubitus boost, a breast irradiation technique. Patients are repositioned and resimulated for electron boost to minimize the necessary depth for the electron beam and optimize target volume coverage. Methods and Materials: A total of 2,606 patients were treated with post-lumpectomy radiation at our institution between January 1, 2000, and February 1, 2008. Of these, 231 patients underwent resimulation in the lateral decubitus position with electron boost. Distance from skin to the maximal depth of target volume was measured in both the original and boost plans. Age, body mass index (BMI), boost electronmore » energy, and skin reaction were evaluated. Results: Resimulation in the lateral decubitus position reduced the distance from skin to maximal target volume depth in all patients. Average depth reduction by repositioning was 2.12 cm, allowing for an average electron energy reduction of approximately 7 MeV. Mean skin entrance dose was reduced from about 90% to about 85% (p < 0.001). Only 14 patients (6%) experienced moist desquamation in the boost field at the end of treatment. Average BMI of these patients was 30.4 (range, 17.8-50.7). BMI greater than 30 was associated with more depth reduction by repositioning and increased risk of moist desquamation. Conclusions: The lateral decubitus position allows for a decrease in the distance from the skin to the target volume depth, improving electron coverage of the tumor bed while reducing skin entrance dose. This is a well-tolerated regimen for a patient population with a high BMI or deep tumor location.« less
Moriarty, Frank; Bennett, Kathleen; Cahir, Caitriona; Fahey, Tom
2016-12-01
To characterize prescribing of proton pump inhibitors (PPIs) and medicines that increase gastrointestinal bleeding risk (ulcerogenic) in older people from 1997 to 2012 and assess factors associated with maximal-dose prescribing in long-term PPI users. Repeated cross-sectional study of pharmacy claims data. Eastern Health Board region of Ireland. Individuals aged 65 and older from a means-tested health plan in 1997, 2002, 2007, and 2012 (range 78,489-133,884 individuals). PPI prescribing prevalence was determined per study year, categorized according to duration (≤8 or >8 weeks), dosage (maximal or maintenance), and co-prescribed drugs. Logistic regression in long-term PPI users was used to determine whether age, sex, polypharmacy, and ulcerogenic medicine use were associated with being prescribed a maximal dose rather than a maintenance dose. Adjusted odds ratios (ORs) with 95% confidence intervals (CIs) are presented. Half of this older population received a PPI in 2007 and 2012. Long-term use (>8 weeks) of maximal doses rose from 0.8% of individuals in 1997 to 23.6% in 2012. Although some ulcerogenic medicines and polypharmacy were significantly associated with maximal PPI doses, any nonsteroidal anti-inflammatory drug use was significantly associated with lower odds of maximal PPI dose (adjusted OR = 0.87, 95% CI = 0.85-0.89), as were aspirin use and older age. Adjusting for medication and demographic factors, odds of being prescribed a maximal PPI dose were significantly higher in 2012 than in 1997 (adjusted OR = 6.30, 95% CI = 5.76-6.88). Long-term maximal-dose PPI prescribing is highly prevalent in older adults and is not consistently associated with gastrointestinal bleeding risk factors. Interventions involving prescribers and patients may promote appropriate PPI use, reducing costs and adverse effects of PPI overprescribing. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.
Plasma concentration of ketorolac after local infiltration analgesia in hip arthroplasty.
Affas, F; Eksborg, S; Wretenberg, P; Olofsson, C; Stephanson, N; Stiller, C-O
2014-10-01
Local infiltration analgesia (LIA) with local anaesthetic (ropivacaine), a nonsteroidal anti-inflammatory drug (ketorolac) and epinephrine after lower extremity arthroplasty has gained increasing popularity during the last decade. This method has certain advantages, which include minimal systemic side effects, faster post-operative mobilization, earlier post-operative discharge from hospital and less opioid consumption. However, information regarding plasma concentrations of ketorolac after LIA mixture is insufficient to predict the risk of renal impairment in patients subjected to arthroplasty. To determine the maximal plasma concentration and the exposure of ketorolac during the first 30 h following LIA in hip arthroplasty. Thirteen patients scheduled for primary total hip arthroplasty with LIA (ropivacaine 200 mg, ketorolac 30 mg and epinephrine 0.5 mg in a volume of 106 ml) were included. Plasma concentration of ketorolac was quantified by liquid chromatography-mass spectrometry. In addition, we assessed the effect of increasing age and decreasing glomerular filtration rate on the maximal plasma concentration and the total exposure to ketorolac during 30 h. The range of the maximal plasma concentration, 0.3-2.2 mg/l, was detected 30 min-4 h after completing the infiltration. Similar plasma levels have been reported after intramuscular injection of the same dose of ketorolac to healthy elderly volunteers. Exposure to ketorolac after LIA may be comparable to an intramuscular injection of the same dose. Decision of dose reduction should be based on clinical assessment of risk factors. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
O'Malley, Lauren; Pignol, Jean-Philippe; Beachey, David J; Keller, Brian M; Presutti, Joseph; Sharpe, Michael
2006-05-21
Using efficient immobilization and dedicated beam collimation devices, stereotactic radiosurgery ensures highly conformal treatment of small tumours with limited microscopic extension. One contribution to normal tissue irradiation remains the radiological penumbra. This work aims at demonstrating that intermediate energy photons (IEP), above orthovoltage but below megavoltage, improve dose distribution for stereotactic radiosurgery for small irradiation field sizes due to a dramatic reduction of radiological penumbra. Two different simulation systems were used: (i) Monte Carlo simulation to investigate the dose distribution of monoenergetic IEP between 100 keV and 1 MeV in water phantom; (ii) the Pinnacle3 TPS including a virtual IEP unit to investigate the dosimetry benefit of treating with 11 non-coplanar beams a 2 cm tumour in the middle of a brain adjacent to a 1 mm critical structure. Radiological penumbrae below 300 microm are generated for field size below 2 x 2 cm2 using monoenergetic IEP beams between 200 and 400 keV. An 800 kV beam generated in a 0.5 mm tungsten target maximizes the photon intensity in this range. Pinnacle3 confirms the dramatic reduction in penumbra size. DVHs show for a constant dose distribution conformality, improved dose distribution homogeneity and better sparing of critical structures using a 800 kV beam compared to a 6 MV beam.
NASA Astrophysics Data System (ADS)
O'Malley, Lauren; Pignol, Jean-Philippe; Beachey, David J.; Keller, Brian M.; Presutti, Joseph; Sharpe, Michael
2006-05-01
Using efficient immobilization and dedicated beam collimation devices, stereotactic radiosurgery ensures highly conformal treatment of small tumours with limited microscopic extension. One contribution to normal tissue irradiation remains the radiological penumbra. This work aims at demonstrating that intermediate energy photons (IEP), above orthovoltage but below megavoltage, improve dose distribution for stereotactic radiosurgery for small irradiation field sizes due to a dramatic reduction of radiological penumbra. Two different simulation systems were used: (i) Monte Carlo simulation to investigate the dose distribution of monoenergetic IEP between 100 keV and 1 MeV in water phantom; (ii) the Pinnacle3 TPS including a virtual IEP unit to investigate the dosimetry benefit of treating with 11 non-coplanar beams a 2 cm tumour in the middle of a brain adjacent to a 1 mm critical structure. Radiological penumbrae below 300 µm are generated for field size below 2 × 2 cm2 using monoenergetic IEP beams between 200 and 400 keV. An 800 kV beam generated in a 0.5 mm tungsten target maximizes the photon intensity in this range. Pinnacle3 confirms the dramatic reduction in penumbra size. DVHs show for a constant dose distribution conformality, improved dose distribution homogeneity and better sparing of critical structures using a 800 kV beam compared to a 6 MV beam.
Wink, J; Wolterbeek, R; Aarts, L P H J; Koster, S C E; Versteegh, M I M; Veering, B T H
2013-07-01
Segmental dose reduction with increasing age after thoracic epidural anaesthesia (TEA) has been documented. We hypothesised that after a fixed loading dose of ropivacaine at the T3-T4 level, increasing age would result in more extended analgesic spread. In addition, other aspects of neural blockade and haemodynamic changes were studied. Thirty-five lung surgery patients were included in three age groups. Thirty-one patients received an epidural catheter at the T3-T4 interspace followed by an injection of 8-ml ropivacaine 0.75%. Analgesia was assessed with pinprick and temperature discrimination. Motor block was tested using the Bromage and epidural scoring scale for arm movements score. An arterial line was inserted for invasive measurement of blood pressure, cardiac index (CI) and stroke volume (SV). There was no influence of age on quality of TEA except for the caudal border of analgesia being somewhat lower in the middle and older age group compared with the young age group. Heart rate (6.0 ± 5.9, P < 0.001), mean arterial pressure (16.1 ± 15.6, P < 0.001), CI (0.55 ± 0.49, P < 0.001) and SV (9.6 ± 14.6, P = 0.001) decreased after TEA for the total group. Maximal reduction in heart rate after TEA was more extensive in the young age group compared with the other age groups. There was no effect of age on other cardiovascular parameters. We were unable to demonstrate an effect of age on the maximal number of spinal segments blocked after TEA; however, the caudad spread of analgesia increased with advancing age. In addition, reduction of heart rate was greater in the youngest group. © 2013 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Załuska, Katarzyna; Kondrat-Wróbel, Maria W; Łuszczki, Jarogniew J
2018-05-01
The coexistence of seizures and arterial hypertension requires an adequate and efficacious treatment involving both protection from seizures and reduction of high arterial blood pressure. Accumulating evidence indicates that some diuretic drugs (with a well-established position in the treatment of arterial hypertension) also possess anticonvulsant properties in various experimental models of epilepsy. The aim of this study was to assess the anticonvulsant potency of 6 commonly used diuretic drugs (i.e., amiloride, ethacrynic acid, furosemide, hydrochlorothiazide, indapamide, and spironolactone) in the maximal electroshock-induced seizure threshold (MEST) test in mice. Doses of the studied diuretics and their corresponding threshold increases were linearly related, allowing for the determination of doses which increase the threshold for electroconvulsions in drug-treated animals by 20% (TID20 values) over the threshold in control animals. Amiloride, hydrochlorothiazide and indapamide administered systemically (intraperitoneally - i.p.) increased the threshold for maximal electroconvulsions in mice, and the experimentally-derived TID20 values in the maximal electroshock seizure threshold test were 30.2 mg/kg for amiloride, 68.2 mg/kg for hydrochlorothiazide and 3.9 mg/kg for indapamide. In contrast, ethacrynic acid (up to 100 mg/kg), furosemide (up to 100 mg/kg) and spironolactone (up to 50 mg/kg) administered i.p. had no significant impact on the threshold for electroconvulsions in mice. The studied diuretics can be arranged with respect to their anticonvulsant potency in the MEST test as follows: indapamide > amiloride > hydrochlorothiazide. No anticonvulsant effects were observed for ethacrynic acid, furosemide or spironolactone in the MEST test in mice.
Jett, David A.; Hill, E.F.; Fernando, J.C.; Eldefrawi, M.E.; Eldefrawi, A.T.
1993-01-01
The effect of ad libitum dietary exposure (as occurs in the field) to parathion for 14 d was investigated on the muscarinic acetylcholine receptor (mAChR) in brains and submaxillary glands of adults of a field species, the white-footed mouse Peromyscus leucopus. Immunoprecipitation using subtype selective antibodies revealed that the relative ratios of the m1-m5 mAChR subtypes in Peromyscus brain were similar to those in rat brain. There was little variability in acetylcholinesterase (AChE) activity in control mice brains but large variability in 39 exposed mice, resulting from differences in food ingestion and parathion metabolism. Accordingly, data on radioligand binding to mAChRs in each mouse brain were correlated with brain AChE activity in the same mouse, and AChE inhibition served as a biomarker of exposure reflecting in situ paraoxon concentrations. Exposure to parathion for 14 d reduced maximal binding (Bmax) of [3H]quinuclidinyl benzilate ([3H]QNB), [3H]-N-methylscopolamine ([3H]NMS), and [3H]-4-diphenylacetoxy-N-methylpiperidine methiodide ([3H]-4-DAMP) by up to approximately 58% without affecting receptor affinities for these ligands. Maximal reduction in Bmax of [3H]QNB and [3H]-4-DAMP binding occurred in mice with highest AChE inhibition, while equivalent maximal reduction in Bmax of [3H]NMS occurred in mice with only approximately 10% AChE inhibition, without further change at higher parathion doses. This is believed to be due to the hydrophilicity of [3H]NMS, which limits its accessibility to internalized desensitized receptors. In submaxillary glands (mAChRs are predominantly m3 subtype), there were significant dose-dependent reductions in [3H]QNB binding and m3 mRNA levels in exposed mice, revealed by Northern blot analyses. The reduction in m3 receptors is suggested to result mostly from reduced synthesis at the transcription level, rather than from translational or posttranslational events. The data suggest that down-regulation of mAChRs occurs after dietary exposure for 14 d to sublethal concentrations of parathion in a field rodent species, and that significant though incomplete recovery in AChE and mAChRs occurs in 7 d following termination of exposure.
McGowan, Mary P; Tardif, Jean-Claude; Ceska, Richard; Burgess, Lesley J; Soran, Handrean; Gouni-Berthold, Ioanna; Wagener, Gilbert; Chasan-Taber, Scott
2012-01-01
Mipomersen, an antisense oligonucleotide targeting apolipoprotein B synthesis, significantly reduces LDL-C and other atherogenic lipoproteins in familial hypercholesterolemia when added to ongoing maximally tolerated lipid-lowering therapy. Safety and efficacy of mipomersen in patients with severe hypercholesterolemia was evaluated. Randomized, double-blind, placebo-controlled, multicenter trial. Patients (n = 58) were ≥18 years with LDL-C ≥7.8 mmol/L or LDL-C ≥5.1 mmol/L plus CHD disease, on maximally tolerated lipid-lowering therapy that excluded apheresis. Weekly subcutaneous injections of mipomersen 200 mg (n = 39) or placebo (n = 19) were added to lipid-lowering therapy for 26 weeks. percent reduction in LDL-C from baseline to 2 weeks after the last dose of treatment. Mipomersen (n = 27) reduced LDL-C by 36%, from a baseline of 7.2 mmol/L, for a mean absolute reduction of 2.6 mmol/L. Conversely, mean LDL-C increased 13% in placebo (n = 18) from a baseline of 6.5 mmol/L (mipomersen vs placebo p<0.001). Mipomersen produced statistically significant (p<0.001) reductions in apolipoprotein B and lipoprotein(a), with no change in high-density lipoprotein cholesterol. Mild-to-moderate injection site reactions were the most frequently reported adverse events with mipomersen. Mild-to-moderate flu-like symptoms were reported more often with mipomersen. Alanine transaminase increase, aspartate transaminase increase, and hepatic steatosis occurred in 21%, 13% and 13% of mipomersen treated patients, respectively. Adverse events by category for the placebo and mipomersen groups respectively were: total adverse events, 16(84.2%), 39(100%); serious adverse events, 0(0%), 6(15.4%); discontinuations due to adverse events, 1(5.3%), 8(20.5%) and cardiac adverse events, 1(5.3%), 5(12.8%). Mipomersen significantly reduced LDL-C, apolipoprotein B, total cholesterol and non-HDL-cholesterol, and lipoprotein(a). Mounting evidence suggests it may be a potential pharmacologic option for lowering LDL-C in patients with severe hypercholesterolemia not adequately controlled using existing therapies. Future studies will explore alternative dosing schedules aimed at minimizing side effects. ClinicalTrials.gov NCT00794664.
Ung, Keith T; Rao, Nagaraja; Weers, Jeffry G; Huang, Daniel; Chan, Hak-Kim
2016-09-25
Inhaled drugs all too often deliver only a fraction of the emitted dose to the target lung site due to deposition in the extrathoracic region (i.e., mouth and throat), which can lead to increased variation in lung exposure, and in some instances increases in local and systemic side effects. For aerosol medications, improved targeting to the lungs may be achieved by tailoring the micromeritic properties of the particles (e.g., size, density, rugosity) to minimize deposition in the mouth-throat and maximize the total lung dose. This study evaluated a co-solvent spray drying approach to modulate particle morphology and dose delivery characteristics of engineered powder formulations of insulin microparticles. The binary co-solvent system studied included water as the primary solvent mixed with an organic co-solvent, e.g., ethanol. Factors such as the relative rate of evaporation of each component of a binary co-solvent mixture, and insulin solubility in each component were considered in selecting feedstock compositions. A water-ethanol co-solvent mixture with a composition range considered suitable for modulating particle shell formation during drying was selected for experimental investigation. An Alberta Idealized Throat model was used to evaluate the in vitro total lung dose of a series of spray dried insulin formulations engineered with different bulk powder properties and delivered with two prototype inhalers that fluidize and disperse powder using different principles. The in vitro total lung dose of insulin microparticles was improved and favored for powders with low bulk density and small primary particle size, with reduction of deposition in the extrathoracic region. The results demonstrated that a total lung dose >95% of the delivered dose can be achieved with engineered particles, indicating a high degree of lung targeting, almost completely bypassing deposition in the mouth-throat. Copyright © 2016 Elsevier B.V. All rights reserved.
Singh, Anurag K; Lockett, Mary Ann; Bradley, Jeffrey D
2003-02-01
To evaluate the incidence and clinical/dosimetric predictors of acute and late Radiation Therapy Oncology Group Grade 3-5 esophageal toxicity in patients with non-small-cell lung cancer (NSCLC) treated with definitive three-dimensional conformal radiotherapy (3D-CRT). We retrospectively reviewed the charts of 207 consecutive patients with NSCLC who were treated with high-dose, definitive 3D-CRT between March 1991 and December 1998. This population consisted of 107 men and 100 women. The median age was 67 years (range 31-90). The following patient and treatment parameters were studied: age, gender, race, performance status, sequential chemotherapy, concurrent chemotherapy, presence of subcarinal nodes, pretreatment weight loss, mean dose to the entire esophagus, maximal point dose to the esophagus, and percentage of volume of esophagus receiving >55 Gy. All doses are reported without heterogeneity corrections. The median prescription dose to the isocenter in this population was 70 Gy (range 60-74) delivered in 2-Gy daily fractions. All patients were treated once daily. Acute and late esophageal toxicities were graded by Radiation Therapy Oncology Group criteria. Patient and clinical/dosimetric factors were coded and correlated with acute and late Grade 3-5 esophageal toxicity using univariate and multivariate regression analyses. Of 207 patients, 16 (8%) developed acute (10 patients) or late (13 patients) Grade 3-5 esophageal toxicity. Seven patients had both acute and late Grade 3-5 esophageal toxicity. One patient died (Grade 5 esophageal toxicity) of late esophageal perforation. Concurrent chemotherapy, maximal point dose to the esophagus >58 Gy, and a mean dose to the entire esophagus >34 Gy were significantly associated with a risk of Grade 3-5 esophageal toxicity on univariate analysis. Concurrent chemotherapy and maximal point dose to the esophagus >58 Gy retained significance on multivariate analysis. Of 207 patients, 53 (26%) received concurrent chemotherapy. Fourteen (88%) of the 16 patients who developed Grade 3-5 esophageal toxicity had received concurrent chemotherapy (p = 0.0001, Pearson's chi-square test). No case of Grade 3-5 esophageal toxicity occurred in patients who received a maximal point dose to the esophagus of <58 Gy (p = 0.0001, Fisher's exact test, two-tail). Only 2 patients developed Grade 3-5 esophageal toxicity in the absence of concurrent chemotherapy; both received a maximal esophageal point dose >69 Gy. All assessable patients who developed Grade 3-5 esophageal toxicity had a mean dose to the entire esophagus >34 Gy (p = 0.0351, Pearson's chi-square test). However, the mean dose was not predictive on multivariate analysis. Concurrent chemotherapy and the maximal esophageal point dose were significantly associated with a risk of Grade 3-5 esophageal toxicity in patients with NSCLC treated with high-dose 3D-CRT. In patients who received concurrent chemotherapy, the threshold maximal esophageal point dose for Grade 3-5 esophageal toxicity was 58 Gy. An insufficient number of patients developed Grade 3-5 esophageal toxicity in the absence of chemotherapy to allow a valid statistical analysis of the relationship between the maximal esophageal point dose and esophagitis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rajecki, M; Thurber, A; Catalfamo, F
2015-06-15
Purpose: To describe rectal dose reduction achieved and techniques used to take advantage of the increased peri-rectal spacing provided by injected polyethylene-glycol. Methods: Thirty prostate cancer patents were 2:1 randomized during a clinical trial to evaluate the effectiveness of injected poly-ethylene glycol hydrogel (SpaceOAR System) in creating space between the prostate and the anterior rectal wall. All patients received a baseline CT/MR scan and baseline IMRT treatment plan. Patients were randomized to receive hydrogel injection (n=20) or Control (n=10), followed by another CT/MR scan and treatment plan (single arc VMAT, 6 MV photons, 79.2 Gy, 44 fractions). Additional optimization structuresmore » were employed to constrain the dose to the rectum; specifically an avoidance structure to limit V75 <15%, and a control structure to limit the maximum relative dose <105% in the interface region of the anterior rectal wall and the prostate planning target volume. Dose volumetric data was analyzed for rectal volumes receiving 60 through 80 Gy. Results: Rectal dose reduction was observed in all patients who received the hydrogel. Volumetric analysis indicates a median rectal volume and (reduction from baseline plan) following spacer application of 4.9% (8.9%) at V60Gy, 3.8% (8.1%) at V65Gy, 2.5% (7.2%) at V70Gy, 1.6% (5.8%) at V75Gy, and 0.5% (2.5%) at V80Gy. Conclusion: Relative to planning without spacers, rectal dose constraints of 5%, 4%, 3%, 2%, 1% for V60, V65, V70, V75, and V80, should be obtainable when peri-rectal spacers are used. The combined effect of increased peri-rectal space provided by the hydrogel, with strict optimization objectives, resulted in reduced dose to the rectum. To maximize benefit, strict optimization objectives and reduced rectal dose constraints should be employed when creating plans for patients with perirectal spacers. Clinical Trial for SpaceOAR product conducted by Augmenix,Inc. The research site was paid to be a participating site.« less
Reeves, Ginger; Hathorne, Heather; Solomon, G. Martin; Abbi, Smita; Renard, Didier; Lock, Ruth; Zhou, Ping; Danahay, Henry; Clancy, John P.; Waltz, David A.
2013-01-01
Background: Prostasin, a trypsin-like serine protease, is a channel-activating protease and major regulator of epithelial sodium channel-mediated sodium absorption. Its direct inhibition by camostat represents a potential approach to inhibiting sodium transport in cystic fibrosis (CF). Methods: To determine whether a topical formulation of camostat represents an efficacious and tolerable approach to reducing Na+ transport in the CF airway, we conducted a two-part randomized, double-blind, placebo-controlled, crossover, ascending single-dose study to evaluate the pharmacodynamics, safety, and pharmacokinetics of camostat administered through a nasal spray pump in subjects with CF. Nasal potential difference (PD) was measured before and after treatment, and safety and pharmacokinetics were assessed by a standardized approach. Results: In part 1, nine subjects were enrolled, and six completed crossover dosing at the maximally tolerated dose. The change in maximal (most polarizing) basal PD 2 h following administration of camostat was +13.1 mV (1.6-mg dose group) compared with −8.6 mV following placebo (P < .005). Intrasubject change in Ringer and amiloride-sensitive PDs exhibited similar and consistent responses. Bayesian analysis in an additional six subjects in part 2 estimated a dose of 18 μg/mL to provide 50% of the maximum effect. There was no significant change in chloride transport or total nasal symptom score, nasal examination rating, and laboratory parameters. Conclusions: This study establishes the proof of concept that a reduction in sodium transport in the human CF airway can be achieved through inhibition of prostasin activity, identifying a potential therapeutic target in the disease. Trial registration: ClinicalTrials.gov; No.: NCT00506792; URL: www.clinicaltrials.gov PMID:23412700
Accelerated Partial Breast Irradiation: What is Dosimetric Effect of Advanced Technology Approaches?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moran, Jean M.; Ben-David, Merav A.; Marsh, Robin B.
2009-09-01
Purpose: The present treatment planning study compared whole breast radiotherapy (WBRT) to accelerated partial breast irradiation (APBI) for different external beam techniques and geometries (e.g., free breathing [FB] and deep inspiration breath hold [DIBH]). Methods and Materials: After approval by our institutional review board, a treatment planning study was performed of 10 patients with left-sided Stage 0-I breast cancer enrolled in a Phase I-II study of APBI using intensity-modulated radiotherapy (IMRT). After lumpectomy, patients underwent planning computed tomography scans during FB and using an active breathing control device at DIBH. For the FB geometry, standard WBRT and three-dimensional conformal radiotherapymore » (3D-CRT) APBI plans were created. For the DIBH geometry with active breathing control, WBRT, 3D-CRT, and IMRT APBI plans were created. Results: All APBI techniques had excellent planning target volume coverage. The maximal planning target volume dose was reduced from 116% of the prescription dose to 108% with the IMRT(DIBH) APBI plan. The maximal heart dose was >30 Gy for the WBRT techniques, 8.2 Gy for 3D-CRT(FB), and <5.0 Gy for 3D-CRT(DIBH) and IMRT(DIBH) techniques. The mean left anterior descending artery dose was significantly reduced from 11.4 Gy with WBRT(FB) to 4.2 with WBRT(DIBH) and <2.0 Gy with all APBI techniques. Conclusion: Although planning target volume coverage was acceptable with all techniques, the plans using the DIBH geometry resulted in a marked reduction in the normal tissue dose compared with WBRT planned in the absence of cardiac blocking. Additional study is needed to determine whether these techniques result in clinical benefits.« less
Sun, Xiaoli; Zhang, Yan; Yang, Wenlan; Liu, Jinming
2015-04-01
This study in healthy adults was conducted to explore the clinical application of capnovolumetric indices as compared to lung function parameters using histamine provocation. Forty healthy subjects received aerosol histamine or salbutamol in an automatic stimulation system with escalating doses of histamine. Dead space volumes of capnovolumetry and lung function parameters were examined with increased concentrations of histamine at a fixed time interval. The doses of histamine were selected from 0.0562 mg-2.2 mg and 0.1 mg salbutamol was inhaled when a maximal dose of histamine was reached. Baseline values in each group were calculated prior to histamine inhalation. Fowler dead space (VDF), Wolff dead space (VDW), threshold dead space (VDT), Bohr dead space (VDB), forced expiratory volume in 1 s (FEV1 ) and peak expiratory flow (PEF) showed a dose-dependent reduction following histamine provocation, but there were no statistical differences in the measurements at baseline and post S6 provocation. The value of dC3/DV at the maximal dose was significantly increased over its baseline value (P < 0.05). VDF, VDT and VDW were significantly increased after bronchodilator use (P < 0.05 or <0.01). The changes in capnovolumetry did not correspond with the results of lung function test. The dC3/DV and airway dead spaces of capnovolumetry in healthy adults are significantly increased compared to lung function parameters before or after bronchodilator use, suggesting that capnovolumetry is feasible in diagnostic evaluation of airway reactivity, especially for persons who are unable to undertake lung function test. © 2014 John Wiley & Sons Ltd.
Bakris, George L; Sica, Domenic; Weber, Michael; White, William B; Roberts, Andrew; Perez, Alfonso; Cao, Charlie; Kupfer, Stuart
2011-02-01
The current study assesses the antihypertensive efficacy and safety of the investigational angiotensin receptor blocker (ARB), azilsartan medoxomil (AZL-M), compared with placebo and the ARB olmesartan medoxomil (OLM-M). This randomized, double-blind, placebo-controlled, multicenter study assessed change from baseline in mean 24-hour ambulatory systolic blood pressure (SBP) following 6 weeks of treatment. Patients with primary hypertension (n=1275) and baseline 24-hour mean ambulatory systolic pressure ≥ 130 mm Hg and ≤ 170 mm Hg were studied; 142 received placebo and the remainder received 20 mg, 40 mg, or 80 mg AZL-M or 40 mg OLM-M. Mean age of participants was 58 ± 11 years, baseline mean 24-hour SBP was 146 mm Hg. Dose-dependent reductions in 24-hour mean SBP at study end occurred in all AZL-M groups. Reduction in 24-hour mean SBP was greater with AZL-M 80 mg than OLM-M 40 mg by 2.1 mm Hg (95% confidence interval, -4.0 to -0.1; P=.038), while AZL-M 40 mg was noninferior to OLM-M 40 mg. The side effect profiles of both ARBs were similar to placebo. AZL-M is well tolerated and more efficacious at its maximal dose than the highest dose of OLM-M. © 2011 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Romesser, Paul B.; Qureshi, Muhammad M.; Kovalchuk, Nataliya
2014-07-01
To determine the effect of gross tumor volume of the primary (GTV-P) and nodal (GTV-N) disease on planned radiation dose to the brachial plexus (BP) in head and neck intensity-modulated radiotherapy (IMRT). Overall, 75 patients underwent definitive IMRT to a median total dose of 69.96 Gy in 33 fractions. The right BP and left BP were prospectively contoured as separate organs at risk. The GTV was related to BP dose using the unpaired t-test. Receiver operating characteristics curves were constructed to determine optimized volumetric thresholds of GTV-P and GTV-N corresponding to a maximum BP dose cutoff of > 66 Gy.more » Multivariate analyses were performed to account for factors associated with a higher maximal BP dose. A higher maximum BP dose (> 66 vs ≤ 66 Gy) correlated with a greater mean GTV-P (79.5 vs 30.8 cc; p = 0.001) and ipsilateral GTV-N (60.6 vs 19.8 cc; p = 0.014). When dichotomized by the optimized nodal volume, patients with an ipsilateral GTV-N ≥ 4.9 vs < 4.9 cc had a significant difference in maximum BP dose (64.2 vs 59.4 Gy; p = 0.001). Multivariate analysis confirmed that an ipsilateral GTV-N ≥ 4.9 cc was an independent predictor for the BP to receive a maximal dose of > 66 Gy when adjusted individually for BP volume, GTV-P, the use of a low anterior neck field technique, total planned radiation dose, and tumor category. Although both the primary and the nodal tumor volumes affected the BP maximal dose, the ipsilateral nodal tumor volume (GTV-N ≥ 4.9 cc) was an independent predictor for high maximal BP dose constraints in head and neck IMRT.« less
McGowan, Mary P.; Tardif, Jean-Claude; Ceska, Richard; Burgess, Lesley J.; Soran, Handrean; Gouni-Berthold, Ioanna; Wagener, Gilbert; Chasan-Taber, Scott
2012-01-01
Objectives Mipomersen, an antisense oligonucleotide targeting apolipoprotein B synthesis, significantly reduces LDL-C and other atherogenic lipoproteins in familial hypercholesterolemia when added to ongoing maximally tolerated lipid-lowering therapy. Safety and efficacy of mipomersen in patients with severe hypercholesterolemia was evaluated. Methods and Results Randomized, double-blind, placebo-controlled, multicenter trial. Patients (n = 58) were ≥18 years with LDL-C ≥7.8 mmol/L or LDL-C ≥5.1 mmol/L plus CHD disease, on maximally tolerated lipid-lowering therapy that excluded apheresis. Weekly subcutaneous injections of mipomersen 200 mg (n = 39) or placebo (n = 19) were added to lipid-lowering therapy for 26 weeks. Main outcome: percent reduction in LDL-C from baseline to 2 weeks after the last dose of treatment. Mipomersen (n = 27) reduced LDL-C by 36%, from a baseline of 7.2 mmol/L, for a mean absolute reduction of 2.6 mmol/L. Conversely, mean LDL-C increased 13% in placebo (n = 18) from a baseline of 6.5 mmol/L (mipomersen vs placebo p<0.001). Mipomersen produced statistically significant (p<0.001) reductions in apolipoprotein B and lipoprotein(a), with no change in high-density lipoprotein cholesterol. Mild-to-moderate injection site reactions were the most frequently reported adverse events with mipomersen. Mild-to-moderate flu-like symptoms were reported more often with mipomersen. Alanine transaminase increase, aspartate transaminase increase, and hepatic steatosis occurred in 21%, 13% and 13% of mipomersen treated patients, respectively. Adverse events by category for the placebo and mipomersen groups respectively were: total adverse events, 16(84.2%), 39(100%); serious adverse events, 0(0%), 6(15.4%); discontinuations due to adverse events, 1(5.3%), 8(20.5%) and cardiac adverse events, 1(5.3%), 5(12.8%). Conclusion Mipomersen significantly reduced LDL-C, apolipoprotein B, total cholesterol and non-HDL-cholesterol, and lipoprotein(a). Mounting evidence suggests it may be a potential pharmacologic option for lowering LDL-C in patients with severe hypercholesterolemia not adequately controlled using existing therapies. Future studies will explore alternative dosing schedules aimed at minimizing side effects. Trial Registration ClinicalTrials.gov NCT00794664. PMID:23152839
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stewart, Alexandra J.; Cormack, Robert A.; Lee, Hang
2008-11-01
Purpose: To investigate the effect of bladder filling on dosimetry and to determine the best bladder dosimetric parameter for vaginal cuff brachytherapy. Methods and Materials: In this prospective clinical trial, a total of 20 women underwent vaginal cylinder high-dose-rate brachytherapy. The bladder was full for Fraction 2 and empty for Fraction 3. Dose-volume histogram and dose-surface histogram values were generated for the bladder, rectum, and urethra. The midline maximal bladder point (MBP) and the midline maximal rectal point were recorded. Paired t tests, Pearson correlations, and regression analyses were performed. Results: The volume and surface area of the irradiated bladdermore » were significantly smaller when the bladder was empty than when full. Of the several dose-volume histogram and dose-surface histogram parameters evaluated, the bladder maximal dose received by 2 cm{sup 3} of tissue, volume of bladder receiving {>=}50% of the dose, volume of bladder receiving {>=}70% of the dose, and surface area of bladder receiving {>=}50% of the dose significantly predicted for the difference between the empty vs. full filling state. The volume of bladder receiving {>=}70% of the dose and the maximal dose received by 2 cm{sup 3} of tissue correlated significantly with the MBP. Bladder filling did not alter the volume or surface area of the rectum irradiated. However, an empty bladder did result in the nearest point of bowel being significantly closer to the vaginal cylinder than when the bladder was full. Conclusions: Patients undergoing vaginal cuff brachytherapy treated with an empty bladder have a lower bladder dose than those treated with a full bladder. The MBP correlated well with the volumetric assessments of bladder dose and provided a noninvasive method for reporting the MBP dose using three-dimensional imaging. The MBP can therefore be used as a surrogate for complex dosimetry in the clinic.« less
USDA-ARS?s Scientific Manuscript database
We measured plasma markers of cholesterol synthesis (lathosterol) and absorption (campesterol, sitosterol, and cholestanol) in order to compare the effects of maximal doses of rosuvastatin with atorvastatin and investigate the basis for the significant individual variation in lipid lowering response...
USDA-ARS?s Scientific Manuscript database
Maximal doses of atorvastatin and rosuvastatin are highly effective in lowering low-density lipoprotein (LDL) cholesterol and triglyceride levels; however, rosuvastatin has been shown to be significantly more effective than atorvastatin in lowering LDL cholesterol and in increasing high-density lipo...
ENabling Reduction of Low-grade Inflammation in SEniors Pilot Study: Concept, Rationale, and Design.
Manini, Todd M; Anton, Stephen D; Beavers, Daniel P; Cauley, Jane A; Espeland, Mark A; Fielding, Roger A; Kritchevsky, Stephen B; Leeuwenburgh, Christiaan; Lewis, Kristina H; Liu, Christine; McDermott, Mary M; Miller, Michael E; Tracy, Russell P; Walston, Jeremy D; Radziszewska, Barbara; Lu, Jane; Stowe, Cindy; Wu, Samuel; Newman, Anne B; Ambrosius, Walter T; Pahor, Marco
2017-09-01
To test two interventions to reduce interleukin (IL)-6 levels, an indicator of low-grade chronic inflammation and an independent risk factor for impaired mobility and slow walking speed in older adults. The ENabling Reduction of low-Grade Inflammation in SEniors (ENRGISE) Pilot Study was a multicenter, double-blind, placebo-controlled randomized pilot trial of two interventions to reduce IL-6 levels. Five university-based research centers. Target enrollment was 300 men and women aged 70 and older with an average plasma IL-6 level between 2.5 and 30 pg/mL measured twice at least 1 week apart. Participants had low to moderate physical function, defined as self-reported difficulty walking one-quarter of a mile or climbing a flight of stairs and usual walk speed of less than 1 m/s on a 4-m usual-pace walk. Participants were randomized to losartan, omega-3 fish oil (ω-3), combined losartan and ω-3, or placebo. Randomization was stratified depending on eligibility for each group. A titration schedule was implemented to reach a dose that was safe and effective for IL-6 reduction. Maximal doses were 100 mg/d for losartan and 2.8 g/d for ω-3. IL-6, walking speed over 400 m, physical function (Short Physical Performance Battery), other inflammatory markers, safety, tolerability, frailty domains, and maximal leg strength were measured. Results from the ENRGISE Pilot Study will provide recruitment yields, feasibility, medication tolerance and adherence, and preliminary data to help justify a sample size for a more definitive randomized trial. The ENRGISE Pilot Study will inform a larger subsequent trial that is expected to have important clinical and public health implications for the growing population of older adults with low-grade chronic inflammation and mobility limitations. © 2017, Copyright the Authors Journal compilation © 2017, The American Geriatrics Society.
Skorupski, Katherine A.; O'Brien, Thomas G.; Guerrero, Teri; Rodriguez, Carlos O.; Burns, Mark R.
2011-01-01
Polyamines are essential for cell proliferation. Their production is dysregulated in many cancers and polyamine depletion leads to tumor regression in mouse models of SCC. The purpose of this study was to determine the maximally tolerated dose of the polyamine transport inhibitor, MQT 1426, when combined with the ornithine decarboxylase inhibitor, DFMO, and to determine whether this therapy results in reduction in tumor polyamine levels. Thirteen cats with oral SCC received both drugs orally and serial tumor biopsies were obtained for polyamine measurement. Cats were monitored for response to therapy and toxicity. A maximum tolerated dose of MQT 1426 when combined with DFMO was determined. Dose limiting toxicity was vestibular in nature, but was fully reversible. Spermidine and total polyamine levels decreased significantly in tissues, 2 cats experienced objective tumor regression, and 6 cats had stable disease. These results suggest that further study of polyamine depletion therapies is warranted. PMID:22077408
Lee, Jia-Cheng; Chuang, Keh-Shih; Chen, Yi-Wei; Hsu, Fang-Yuh; Chou, Fong-In; Yen, Sang-Hue; Wu, Yuan-Hung
2017-01-01
Diffuse intrinsic pontine glioma is a very frustrating disease. Since the tumor infiltrates the brain stem, surgical removal is often impossible. For conventional radiotherapy, the dose constraint of the brain stem impedes attempts at further dose escalation. Boron neutron capture therapy (BNCT), a targeted radiotherapy, carries the potential to selectively irradiate tumors with an adequate dose while sparing adjacent normal tissue. In this study, 12 consecutive patients treated with conventional radiotherapy in our institute were reviewed to evaluate the feasibility of BNCT. NCTPlan Ver. 1.1.44 was used for dose calculations. Compared with two and three fields, the average maximal dose to the normal brain may be lowered to 7.35 ± 0.72 Gy-Eq by four-field irradiation. The mean ratio of minimal dose to clinical target volume and maximal dose to normal tissue was 2.41 ± 0.26 by four-field irradiation. A therapeutic benefit may be expected with multi-field boron neutron capture therapy to treat diffuse intrinsic pontine glioma without craniotomy, while the maximal dose to the normal brain would be minimized by using the four-field setting.
Lee, Jia-Cheng; Chuang, Keh-Shih; Chen, Yi-Wei; Hsu, Fang-Yuh; Chou, Fong-In; Yen, Sang-Hue
2017-01-01
Diffuse intrinsic pontine glioma is a very frustrating disease. Since the tumor infiltrates the brain stem, surgical removal is often impossible. For conventional radiotherapy, the dose constraint of the brain stem impedes attempts at further dose escalation. Boron neutron capture therapy (BNCT), a targeted radiotherapy, carries the potential to selectively irradiate tumors with an adequate dose while sparing adjacent normal tissue. In this study, 12 consecutive patients treated with conventional radiotherapy in our institute were reviewed to evaluate the feasibility of BNCT. NCTPlan Ver. 1.1.44 was used for dose calculations. Compared with two and three fields, the average maximal dose to the normal brain may be lowered to 7.35 ± 0.72 Gy-Eq by four-field irradiation. The mean ratio of minimal dose to clinical target volume and maximal dose to normal tissue was 2.41 ± 0.26 by four-field irradiation. A therapeutic benefit may be expected with multi-field boron neutron capture therapy to treat diffuse intrinsic pontine glioma without craniotomy, while the maximal dose to the normal brain would be minimized by using the four-field setting. PMID:28662135
Astarita, Giuseppe; Di Giacomo, Barbara; Gaetani, Silvana; Oveisi, Fariba; Compton, Timothy R; Rivara, Silvia; Tarzia, Giorgio; Mor, Marco; Piomelli, Daniele
2006-08-01
Oleoylethanolamide (OEA) is an endogenous lipid mediator that reduces food intake, promotes lipolysis, and decreases body weight gain in rodents by activating peroxisome proliferator-activated receptor-alpha (PPAR-alpha). The biological effects of OEA are terminated by two intracellular lipid hydrolase enzymes, fatty-acid amide hydrolase and N-acylethanolamine-hydrolyzing acid amidase. In the present study, we describe OEA analogs that resist enzymatic hydrolysis, activate PPAR-alpha with high potency in vitro, and persistently reduce feeding when administered in vivo either parenterally or orally. The most potent of these compounds, (Z)-(R)-9-octadecenamide,N-(2-hydroxyethyl,1-methyl) (KDS-5104), stimulates transcriptional activity of PPAR-alpha with a half-maximal effective concentration (EC50) of 100 +/- 21 nM (n = 11). Parenteral administration of KDS-5104 in rats produces persistent dose-dependent prolongation of feeding latency and postmeal interval (half-maximal effective dose, ED50 = 2.4 +/- 1.8 mg kg(-1) i.p.; n = 18), as well as increased and protracted tissue exposure compared with OEA. Oral administration of the compound also results in a significant tissue exposure and reduction of food intake in free-feeding rats. These results suggest that the endogenous high-affinity PPAR-alpha agonist OEA may provide a scaffold for the discovery of novel orally active PPAR-alpha ligands.
In vivo interaction of ketoconazole and sucralfate in healthy volunteers.
Carver, P L; Berardi, R R; Knapp, M J; Rider, J M; Kauffman, C A; Bradley, S F; Atassi, M
1994-01-01
Absorption of ketoconazole is impaired in subjects with an increased gastric pH due to administration of antacids, H2-receptor antagonists, proton pump inhibitors, or the presence of hypochlorhydria. Sucralfate could provide an attractive alternative in patients receiving ketoconazole who require therapy for acid-peptic disorders. Twelve healthy human volunteers were administered a single 400-mg oral dose of ketoconazole in each of three randomized treatment phases. In phase A, ketoconazole was administered orally with 240 ml of water. In phase B, ketoconazole and sucralfate (1.0 g) were administered simultaneously with 240 ml of water. In phase C, ketoconazole was administered with 240 ml of water 2 h after administration of sucralfate (1.0 g) orally with 240 ml of water. A 680-mg oral dose of glutamic acid hydrochloride was administered 10 min prior to and with each dose of ketoconazole, sucralfate, or ketoconazole plus sucralfate. Simultaneous administration of ketoconazole and sucralfate led to a significant reduction in the area under the concentration-time curve and maximal concentration of ketoconazole in serum (78.12 +/- 12.20 versus 59.32 +/- 13.61 micrograms.h/ml and 12.34 +/- 3.07 versus 8.92 +/- 2.57 micrograms/ml, respectively; P < 0.05). When ketoconazole was administered 2 h after sucralfate, the observed ketoconazole area under the concentration-time curve was not significantly decreased compared with that of ketoconazole alone. The time to maximal concentrations in serum and the ketoconazole elimination rate constant were not significantly different in any of the three treatment phases. In patients receiving concurrent administration of ketoconazole and sucralfate, doses should be separated by at least 2 h. PMID:7910724
Bupropion-SR, sertraline, or venlafaxine-XR after failure of SSRIs for depression.
Rush, A John; Trivedi, Madhukar H; Wisniewski, Stephen R; Stewart, Jonathan W; Nierenberg, Andrew A; Thase, Michael E; Ritz, Louise; Biggs, Melanie M; Warden, Diane; Luther, James F; Shores-Wilson, Kathy; Niederehe, George; Fava, Maurizio
2006-03-23
After unsuccessful treatment for depression with a selective serotonin-reuptake inhibitor (SSRI), it is not known whether switching to one antidepressant is more effective than switching to another. We randomly assigned 727 adult outpatients with a nonpsychotic major depressive disorder who had no remission of symptoms or could not tolerate the SSRI citalopram to receive one of the following drugs for up to 14 weeks: sustained-release bupropion (239 patients) at a maximal daily dose of 400 mg, sertraline (238 patients) at a maximal daily dose of 200 mg, or extended-release venlafaxine (250 patients) at a maximal daily dose of 375 mg. The study was conducted in 18 primary and 23 psychiatric care settings. The primary outcome was symptom remission, defined by a total score of 7 or less on the 17-item Hamilton Rating Scale for Depression (HRSD-17) at the end of the study. Scores on the Quick Inventory of Depressive Symptomatology - Self Report (QIDS-SR-16), obtained at treatment visits, determined secondary outcomes, including remission (a score of 5 or less at exit) and response (a reduction of 50 percent or more on baseline scores). Remission rates as assessed by the HRSD-17 and the QIDS-SR-16, respectively, were 21.3 percent and 25.5 percent for sustained-release bupropion, 17.6 percent and 26.6 percent for sertraline, and 24.8 percent and 25.0 percent for extended-release venlafaxine. QIDS-SR-16 response rates were 26.1 percent for sustained-release bupropion, 26.7 percent for sertraline, and 28.2 percent for extended-release venlafaxine. These treatments did not differ significantly with respect to outcomes, tolerability, or adverse events. After unsuccessful treatment with an SSRI, approximately one in four patients had a remission of symptoms after switching to another antidepressant. Any one of the medications in the study provided a reasonable second-step choice for patients with depression. (ClinicalTrials.gov number, NCT00021528.). Copyright 2006 Massachusetts Medical Society.
Li, Ke; Gomez-Cardona, Daniel; Hsieh, Jiang; Lubner, Meghan G.; Pickhardt, Perry J.; Chen, Guang-Hong
2015-01-01
Purpose: For a given imaging task and patient size, the optimal selection of x-ray tube potential (kV) and tube current-rotation time product (mAs) is pivotal in achieving the maximal radiation dose reduction while maintaining the needed diagnostic performance. Although contrast-to-noise (CNR)-based strategies can be used to optimize kV/mAs for computed tomography (CT) imaging systems employing the linear filtered backprojection (FBP) reconstruction method, a more general framework needs to be developed for systems using the nonlinear statistical model-based iterative reconstruction (MBIR) method. The purpose of this paper is to present such a unified framework for the optimization of kV/mAs selection for both FBP- and MBIR-based CT systems. Methods: The optimal selection of kV and mAs was formulated as a constrained optimization problem to minimize the objective function, Dose(kV,mAs), under the constraint that the achievable detectability index d′(kV,mAs) is not lower than the prescribed value of d℞′ for a given imaging task. Since it is difficult to analytically model the dependence of d′ on kV and mAs for the highly nonlinear MBIR method, this constrained optimization problem is solved with comprehensive measurements of Dose(kV,mAs) and d′(kV,mAs) at a variety of kV–mAs combinations, after which the overlay of the dose contours and d′ contours is used to graphically determine the optimal kV–mAs combination to achieve the lowest dose while maintaining the needed detectability for the given imaging task. As an example, d′ for a 17 mm hypoattenuating liver lesion detection task was experimentally measured with an anthropomorphic abdominal phantom at four tube potentials (80, 100, 120, and 140 kV) and fifteen mA levels (25 and 50–700) with a sampling interval of 50 mA at a fixed rotation time of 0.5 s, which corresponded to a dose (CTDIvol) range of [0.6, 70] mGy. Using the proposed method, the optimal kV and mA that minimized dose for the prescribed detectability level of d℞′=16 were determined. As another example, the optimal kV and mA for an 8 mm hyperattenuating liver lesion detection task were also measured using the developed framework. Both an in vivo animal and human subject study were used as demonstrations of how the developed framework can be applied to the clinical work flow. Results: For the first task, the optimal kV and mAs were measured to be 100 and 500, respectively, for FBP, which corresponded to a dose level of 24 mGy. In comparison, the optimal kV and mAs for MBIR were 80 and 150, respectively, which corresponded to a dose level of 4 mGy. The topographies of the iso-d′ map and the iso-CNR map were the same for FBP; thus, the use of d′- and CNR-based optimization methods generated the same results for FBP. However, the topographies of the iso-d′ and iso-CNR map were significantly different in MBIR; the CNR-based method overestimated the performance of MBIR, predicting an overly aggressive dose reduction factor. For the second task, the developed framework generated the following optimization results: for FBP, kV = 140, mA = 350, dose = 37.5 mGy; for MBIR, kV = 120, mA = 250, dose = 18.8 mGy. Again, the CNR-based method overestimated the performance of MBIR. Results of the preliminary in vivo studies were consistent with those of the phantom experiments. Conclusions: A unified and task-driven kV/mAs optimization framework has been developed in this work. The framework is applicable to both linear and nonlinear CT systems such as those using the MBIR method. As expected, the developed framework can be reduced to the conventional CNR-based kV/mAs optimization frameworks if the system is linear. For MBIR-based nonlinear CT systems, however, the developed task-based kV/mAs optimization framework is needed to achieve the maximal dose reduction while maintaining the desired diagnostic performance. PMID:26328971
Santos, Raul D; Duell, P Barton; East, Cara; Guyton, John R; Moriarty, Patrick M; Chin, Wai; Mittleman, Robert S
2015-03-01
To evaluate the efficacy and safety of extended dosing with mipomersen in patients with familial hypercholesterolaemia (HC) taking maximally tolerated lipid-lowering therapy. A planned interim analysis of an ongoing, open-label extension trial in patients (n = 141) with familial HC receiving a subcutaneous injection of 200 mg mipomersen weekly plus maximally tolerated lipid-lowering therapy for up to 104 weeks. The mean changes in low-density lipoprotein cholesterol (LDL-C) from baseline to weeks 26 (n = 130), 52 (n = 111), 76 (n = 66), and 104 (n = 53) were -28, -27, -27, and -28%; and in apolipoprotein B -29, -28, -30, and -31%, respectively. Reductions in total cholesterol, non-high-density lipoprotein-cholesterol, and lipoprotein(a) were comparable with decreases in LDL-C and apolipoprotein B levels. Mean high-density lipoprotein cholesterol increased from baseline by 7 and 6% at weeks 26 and 52, respectively. The long-term safety profile of mipomersen was similar to that reported in the associated randomized placebo-controlled Phase 3 trials. Adverse events included injection site reactions and flu-like symptoms. There was an incremental increase in the median liver fat during the initial 6-12 months that appeared to diminish with continued mipomersen exposure beyond 1 year and returned towards baseline 24 weeks after last drug dose suggestive of adaptation. The median alanine aminotransferase level showed a similar trend over time. Long-term treatment with mipomersen for up to 104 weeks provided sustained reductions in all atherosclerotic lipoproteins measured and a safety profile consistent with prior controlled trials in these high-risk patient populations. CLINICALTRIALS.GOV: NCT00694109. © The Author 2013. Published by Oxford University Press on behalf of the European Society of Cardiology.
Santos, Raul D.; Duell, P. Barton; East, Cara; Guyton, John R.; Moriarty, Patrick M.; Chin, Wai; Mittleman, Robert S.
2015-01-01
Aims To evaluate the efficacy and safety of extended dosing with mipomersen in patients with familial hypercholesterolaemia (HC) taking maximally tolerated lipid-lowering therapy. Methods and results A planned interim analysis of an ongoing, open-label extension trial in patients (n = 141) with familial HC receiving a subcutaneous injection of 200 mg mipomersen weekly plus maximally tolerated lipid-lowering therapy for up to 104 weeks. The mean changes in low-density lipoprotein cholesterol (LDL-C) from baseline to weeks 26 (n = 130), 52 (n = 111), 76 (n = 66), and 104 (n = 53) were −28, −27, −27, and −28%; and in apolipoprotein B −29, −28, −30, and −31%, respectively. Reductions in total cholesterol, non-high-density lipoprotein-cholesterol, and lipoprotein(a) were comparable with decreases in LDL-C and apolipoprotein B levels. Mean high-density lipoprotein cholesterol increased from baseline by 7 and 6% at weeks 26 and 52, respectively. The long-term safety profile of mipomersen was similar to that reported in the associated randomized placebo-controlled Phase 3 trials. Adverse events included injection site reactions and flu-like symptoms. There was an incremental increase in the median liver fat during the initial 6–12 months that appeared to diminish with continued mipomersen exposure beyond 1 year and returned towards baseline 24 weeks after last drug dose suggestive of adaptation. The median alanine aminotransferase level showed a similar trend over time. Conclusion Long-term treatment with mipomersen for up to 104 weeks provided sustained reductions in all atherosclerotic lipoproteins measured and a safety profile consistent with prior controlled trials in these high-risk patient populations. Clinicaltrials.gov NCT00694109. PMID:24366918
Schuchardt, Christiane; Kulkarni, Harshad R.; Shahinfar, Mostafa; Singh, Aviral; Glatting, Gerhard; Baum, Richard P.; Beer, Ambros J.
2016-01-01
In molecular radiotherapy with 177Lu-labeled prostate specific membrane antigen (PSMA) peptides, kidney and/or salivary glands doses limit the activity which can be administered. The aim of this work was to investigate the effect of the ligand amount and injected activity on the tumor-to-normal tissue biologically effective dose (BED) ratio for 177Lu-labeled PSMA peptides. For this retrospective study, a recently developed physiologically based pharmacokinetic model was adapted for PSMA targeting peptides. General physiological parameters were taken from the literature. Individual parameters were fitted to planar gamma camera measurements (177Lu-PSMA I&T) of five patients with metastasizing prostate cancer. Based on the estimated parameters, the pharmacokinetics of tumor, salivary glands, kidneys, total body and red marrow was simulated and time-integrated activity coefficients were calculated for different peptide amounts. Based on these simulations, the absorbed doses and BEDs for normal tissue and tumor were calculated for all activities leading to a maximal tolerable kidney BED of 10 Gy2.5/cycle, a maximal salivary gland absorbed dose of 7.5 Gy/cycle and a maximal red marrow BED of 0.25 Gy15/cycle. The fits yielded coefficients of determination > 0.85, acceptable relative standard errors and low parameter correlations. All estimated parameters were in a physiologically reasonable range. The amounts (for 25−29 nmol) and pertaining activities leading to a maximal tumor dose, considering the defined maximal tolerable doses to organs of risk, were calculated to be 272±253 nmol (452±420 μg) and 7.3±5.1 GBq. Using the actually injected amount (235±155 μg) and the same maximal tolerable doses, the potential improvement for the tumor BED was 1–3 fold. The results suggest that currently given amounts for therapy are in the appropriate order of magnitude for many lesions. However, for lesions with high binding site density or lower perfusion, optimizing the peptide amount and activity might improve the tumor-to-kidney and tumor-to-salivary glands BED ratio considerably. PMID:27611841
Kletting, Peter; Schuchardt, Christiane; Kulkarni, Harshad R; Shahinfar, Mostafa; Singh, Aviral; Glatting, Gerhard; Baum, Richard P; Beer, Ambros J
2016-01-01
In molecular radiotherapy with 177Lu-labeled prostate specific membrane antigen (PSMA) peptides, kidney and/or salivary glands doses limit the activity which can be administered. The aim of this work was to investigate the effect of the ligand amount and injected activity on the tumor-to-normal tissue biologically effective dose (BED) ratio for 177Lu-labeled PSMA peptides. For this retrospective study, a recently developed physiologically based pharmacokinetic model was adapted for PSMA targeting peptides. General physiological parameters were taken from the literature. Individual parameters were fitted to planar gamma camera measurements (177Lu-PSMA I&T) of five patients with metastasizing prostate cancer. Based on the estimated parameters, the pharmacokinetics of tumor, salivary glands, kidneys, total body and red marrow was simulated and time-integrated activity coefficients were calculated for different peptide amounts. Based on these simulations, the absorbed doses and BEDs for normal tissue and tumor were calculated for all activities leading to a maximal tolerable kidney BED of 10 Gy2.5/cycle, a maximal salivary gland absorbed dose of 7.5 Gy/cycle and a maximal red marrow BED of 0.25 Gy15/cycle. The fits yielded coefficients of determination > 0.85, acceptable relative standard errors and low parameter correlations. All estimated parameters were in a physiologically reasonable range. The amounts (for 25-29 nmol) and pertaining activities leading to a maximal tumor dose, considering the defined maximal tolerable doses to organs of risk, were calculated to be 272±253 nmol (452±420 μg) and 7.3±5.1 GBq. Using the actually injected amount (235±155 μg) and the same maximal tolerable doses, the potential improvement for the tumor BED was 1-3 fold. The results suggest that currently given amounts for therapy are in the appropriate order of magnitude for many lesions. However, for lesions with high binding site density or lower perfusion, optimizing the peptide amount and activity might improve the tumor-to-kidney and tumor-to-salivary glands BED ratio considerably.
Tsuji, Brian T; Harigaya, Yoriko; Lesse, Alan J; Forrest, Alan; Ngo, Dung
2013-01-01
AFN-1252, a potent enoyl-ACP reductase (FabI) inhibitor, is under development for the treatment of Staphylococcus aureus infections. The activity of AFN-1252 against two isolates of S. aureus, MSSA 26213 and MRSA S186, was studied in an in vitro pharmacodynamic model simulating AFN-1252 pharmacokinetics in man. Reductions in bacterial viable count over the first 6 hours were generally 1–2 logs and maximal reductions in viable count were generally achieved at fAUC/MIC ratios of 100–200. Maximum reductions in viable count against MSSA 29213 and MRSA S186 were approximately 4 logs, achieved by 450 mg q12h (fAUC/MIC = 1875) dosing at 28 hours. Staphylococcal resistance to AFN-1252 did not develop throughout the 48-hour experiments. As multidrug resistance continues to increase, these studies support the continued investigation of AFN-1252 as a targeted therapeutic for staphylococcal infections. PMID:23433442
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pokhrel, D; Sood, S; Badkul, R
Purpose: To compare dose distributions calculated using PB-hete vs. XVMC algorithms for SRT treatments of cavernous sinus tumors. Methods: Using PB-hete SRT, five patients with cavernous sinus tumors received the prescription dose of 25 Gy in 5 fractions for planning target volume PTV(V100%)=95%. Gross tumor volume (GTV) and organs at risk (OARs) were delineated on T1/T2 MRI-CT-fused images. PTV (range 2.1–84.3cc, mean=21.7cc) was generated using a 5mm uniform-margin around GTV. PB-hete SRT plans included a combination of non-coplanar conformal arcs/static beams delivered by Novalis-TX consisting of HD-MLCs and a 6MV-SRS(1000 MU/min) beam. Plans were re-optimized using XVMC algorithm with identicalmore » beam geometry and MLC positions. Comparison of plan specific PTV(V99%), maximal, mean, isocenter doses, and total monitor units(MUs) were evaluated. Maximal dose to OARs such as brainstem, optic-pathway, spinal cord, and lenses as well as normal tissue volume receiving 12Gy(V12) were compared between two algorithms. All analysis was performed using two-tailed paired t-tests of an upper-bound p-value of <0.05. Results: Using either algorithm, no dosimetrically significant differences in PTV coverage (PTVV99%,maximal, mean, isocenter doses) and total number of MUs were observed (all p-values >0.05, mean ratios within 2%). However, maximal doses to optic-chiasm and nerves were significantly under-predicted using PB-hete (p=0.04). Maximal brainstem, spinal cord, lens dose and V12 were all comparable between two algorithms, with exception of one patient with the largest PTV who exhibited 11% higher V12 with XVMC. Conclusion: Unlike lung tumors, XVMC and PB-hete treatment plans provided similar PTV coverage for cavernous sinus tumors. Majority of OARs doses were comparable between two algorithms, except for small structures such as optic chiasm/nerves which could potentially receive higher doses when using XVMC algorithm. Special attention may need to be paid on a case-by-case basis when planning for sinus SRT based on tumor size and location to OARs particularly the optic apparatus.« less
Effects of tiotropium on lung hyperinflation, dyspnoea and exercise tolerance in COPD.
O'Donnell, D E; Flüge, T; Gerken, F; Hamilton, A; Webb, K; Aguilaniu, B; Make, B; Magnussen, H
2004-06-01
The aim of this study was to test the hypothesis that use of tiotropium, a new long-acting anticholinergic bronchodilator, would be associated with sustained reduction in lung hyperinflation and, thereby, would improve exertional dyspnoea and exercise performance in patients with chronic obstructive pulmonary disease. A randomised, double-blind, placebo-controlled, parallel-group study was conducted in 187 patients (forced expiratory volume in one second 44 +/- 13% pred): 96 patients received 18 microg tiotropium and 91 patients received placebo once daily for 42 days. Spirometry, plethysmographic lung volumes, cycle exercise endurance and exertional dyspnoea intensity at 75% of each patient's maximal work capacity were compared. On day 42, the use of tiotropium was associated with the following effects at pre-dose and post-dose measurements as compared to placebo: vital capacity and inspiratory capacity (IC) increased, with inverse decreases in residual volume and functional residual capacity. Tiotropium increased post-dose exercise endurance time by 105 +/- 40 s (21%) as compared to placebo on day 42. At a standardised time near end-exercise (isotime), IC, tidal volume and minute ventilation all increased, whilst dyspnoea decreased by 0.9 +/- 0.3 Borg scale units. In conclusion, the use of tiotropium was associated with sustained reductions of lung hyperinflation at rest and during exercise. Resultant increases in inspiratory capacity permitted greater expansion of tidal volume and contributed to improvements in both exertional dyspnoea and exercise endurance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van den Heuvel, F; Fiorini, F; George, B
2016-06-15
Purpose: 1) To describe the characteristics of pencil beam proton dose deposition kernels in a homogenous medium using a novel parameterization. 2) To propose a method utilizing this novel parametrization to reduce the measurements and pre-computation required in commissioning a pencil beam proton therapy system. Methods: Using beam data from a clinical, pencil beam proton therapy center, Monte Carlo simulations were performed to characterize the dose depositions at a range of energies from 100.32 to 226.08 MeV in 3.6MeV steps. At each energy, the beam is defined at the surface of the phantom by a two-dimensional Normal distribution. Using FLUKA,more » the in-medium dose distribution is calculated in 200×200×350 mm cube with 1 mm{sup 3} tally volumes. The calculated dose distribution in each 200×200 slice perpendicular to the beam axis is then characterized using a symmetric alpha-stable distribution centered on the beam axis. This results in two parameters, α and γ, that completely describe shape of the distribution. In addition, the total dose deposited on each slice is calculated. The alpha-stable parameters are plotted as function of the depth in-medium, providing a representation of dose deposition along the pencil beam. We observed that these graphs are isometric through a scaling of both abscissa and ordinate map the curves. Results: Using interpolation of the scaling factors of two source curves representative of different beam energies, we predicted the parameters of a third curve at an intermediate energy. The errors are quantified by the maximal difference and provide a fit better than previous methods. The maximal energy difference between the source curves generating identical curves was 21.14MeV. Conclusion: We have introduced a novel method to parameterize the in-phantom properties of pencil beam proton dose depositions. For the case of the Knoxville IBA system, no more than nine pencil beams have to be fully characterized.« less
Phase I study of indicine N-oxide in patients with advanced cancer.
Ohnuma, T; Sridhar, K S; Ratner, L H; Holland, J F
1982-07-01
Indicine N-oxide is a pyrrolizidine alkaloid isolated from Heliotropium indicum, one of the widely used herbs in Ayurvedic medicine. Thirty-seven patients with solid tumors received the drug: 15 men and 22 women (mean age, 53 years). All had had prior chemotherapy, and 25 had had prior radiotherapy. Eighty-four percent had a performance status of 0-3 (Cancer and Leukemia Group B criteria). The drug was given as a short infusion over 15 minutes and repeated with a median interval of 4 weeks. Doses were escalated from 1 to 9 g/m2. A total of 55 courses were evaluable. Dose-limiting toxic effects were leukopenia and thrombocytopenia, and the toxicity was cumulative with repeated doses. Other toxic effects included nausea and vomiting, anemia, and hepatic dysfunction. The hematologic toxicity tended to be more pronounced in patients with hepatic dysfunction, poor marrow reserve, and heavy prior chemotherapy and radiotherapy. There were no complete or partial responses. One patient with skin melanoma and another with ovarian carcinoma had improvement lasting 2 months. The maximally tolerated dose is 9 g/m2 in our population. A recommended dose for therapeutic study is 7 g/m2. High-risk patients should be started at a dose of 5 g/m2. The treatment may be repeated at 4-week intervals with close monitoring of wbc and platelet counts. Dose reductions may be necessary for repeated courses.
Fluid-electrolyte shifts and maximal oxygen uptake in man at simulated altitude /2,287 m/
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Bernauer, E. M.; Adams, W. C.; Juhos, L.
1978-01-01
Experiments were conducted on six trained distance runners (21-23 yr) subjected to an eight-day dietary control at sea level, followed by an eight-day stay in an altitude chamber (2287-m altitude) and a four-day recovery at sea level. Fluid and electrolyte shifts during exercise at altitude were evaluated to gain insight into the mechanism of reduction in working capacity. The results are discussed in terms of resting fluid volumes and blood constituents, maximal exercise variables, and maximal exercise fluid-electrolyte shifts. Since there are no significant changes in fluid balance or resting plasma volume (PV) at altitude, it is concluded that neither these nor the excessive PV shifts with exercise contribute to the reduction in maximal oxygen uptake at altitude. During altitude exposure the percent loss in PV is found to follow the percent reduction in maximal oxygen uptake; however, on the first day of recovery the percent change in PV remains depressed while maximal oxygen uptake returns to control levels.
EMP Attachment 3 DOE-SC PNNL Site Dose Assessment Guidance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snyder, Sandra F.
2011-12-21
This Dose Assessment Guidance (DAG) describes methods to use to determine the Maximally-Exposed Individual (MEI) location and to estimate dose impact to that individual under the U.S. Department of Energy Office of Science (DOE-SC) Pacific Northwest National Laboratory (PNNL) Site Environmental Monitoring Plan (EMP). This guidance applies to public dose from radioactive material releases to the air from PNNL Site operations. This document is an attachment to the Pacific Northwest National Laboratory (PNNL) Environmental Monitoring Plan (EMP) and describes dose assessment guidance for radiological air emissions. The impact of radiological air emissions from the U.S. Department of Energy Office ofmore » Science (DOE-SC) PNNL Site is indicated by dose estimates to a maximally exposed member of the public, referred to as the maximally exposed individual (MEI). Reporting requirements associated with dose to members of the public from radiological air emissions are in 40 CFR Part 61.94, WAC 246-247-080, and DOE Order 458.1. The DOE Order and state standards for dose from radioactive air emissions are consistent with U.S. Environmental Protection Agency (EPA) dose standards in 40 CFR 61.92 (i.e., 10 mrem/yr to a MEI). Despite the fact that the current Contract Requirements Document (CRD) for the DOE-SC PNNL Site operations does not include the requirement to meet DOE CRD 458.1, paragraph 2.b, public dose limits, the DOE dose limits would be met when EPA limits are met.« less
Sarchuk, V N; Golubova, I F; Bikmetov, M S
1990-01-01
The trend in the aerobic reserve obtained from maximal oxygen utilization and other clinicophysiological indices was investigated for children with scoliosis stage I, II and III on pelotherapy and hydrokinesitherapy in the pool. The aim was to design therapeutic regiments differentiated by the patients' initial functional condition. Baseline reduction of the aerobic reserve was recorded in 35% of the examinees. The response to balneopelotherapy appeared more pronounced when the treatment was adjusted to initial functional condition of the child. Functional classes of scoliosis were defined to justify dosing of balneotherapy and peloids by temperature of water, mud, duration of the procedure and the whole course.
Laber, Eric B; Wu, Fan; Munera, Catherine; Lipkovich, Ilya; Colucci, Salvatore; Ripa, Steve
2018-04-30
There is growing interest and investment in precision medicine as a means to provide the best possible health care. A treatment regime formalizes precision medicine as a sequence of decision rules, one per clinical intervention period, that specify if, when and how current treatment should be adjusted in response to a patient's evolving health status. It is standard to define a regime as optimal if, when applied to a population of interest, it maximizes the mean of some desirable clinical outcome, such as efficacy. However, in many clinical settings, a high-quality treatment regime must balance multiple competing outcomes; eg, when a high dose is associated with substantial symptom reduction but a greater risk of an adverse event. We consider the problem of estimating the most efficacious treatment regime subject to constraints on the risk of adverse events. We combine nonparametric Q-learning with policy-search to estimate a high-quality yet parsimonious treatment regime. This estimator applies to both observational and randomized data, as well as settings with variable, outcome-dependent follow-up, mixed treatment types, and multiple time points. This work is motivated by and framed in the context of dosing for chronic pain; however, the proposed framework can be applied generally to estimate a treatment regime which maximizes the mean of one primary outcome subject to constraints on one or more secondary outcomes. We illustrate the proposed method using data pooled from 5 open-label flexible dosing clinical trials for chronic pain. © 2018 The Authors. Statistics in Medicine Published by John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Lim, Karen Siah Huey
Hypothesis: In intensity modulated radiotherapy (IMRT) for cervix cancer, the dose received by the tumour target and surrounding normal tissues is significantly different to that indicated by a single static plan. Rationale: The optimal use of IMRT in cervix cancer requires a greater attention to clinical target volume (CTV) definition and tumour & normal organ motion to assure maximum tumour control with the fewest side effects. Research Aims: 1) Generate consensus CTV contouring guidelines for cervix cancer; 2) Evaluate intra-pelvic tumour and organ dynamics during radiotherapy; 3) Analyze the dose consequences of intra-pelvic organ dynamics on different radiotherapy strategies. Results: Consensus CTV definitions were generated using experts-in-the-field. Substantial changes in tumour volume and organ motion, resulted in significant reductions in accumulated dose to tumour targets and variability in accumulated dose to surrounding normal tissues. Significance: Formalized CTV definitions for cervix cancer is important in ensuring consistent standards of practice. Complex and unpredictable tumour and organ dynamics mandates daily soft-tissue image guidance if IMRT is used. To maximize the benefits of IMRT for cervix cancer, a strategy of adaptation is necessary.
Davison, Kade; Howe, Peter R C
2015-11-18
The metabolic syndrome is a pathological state whereby cardiovascular and metabolic dysfunction coexist and typically progress in a mutual feed-forward manner to further dysfunction and ultimately disease. The health and function of the vascular endothelium is integral in this phenomenon and thus represents a logical target for intervention. Consumption of foods high in cocoa flavanols has demonstrated a capacity to markedly improve endothelial function and key markers of the metabolic syndrome including blood pressure and insulin sensitivity. The typically high energy content of foods containing sufficient doses of cocoa flavanols has caused some reservations around its therapeutic use, but this is dependent upon the particulars of the food matrix used. Further to this, the food matrix appears to influence the dose response curve of cocoa flavanols, particularly on blood pressure, with dark chocolate appearing to be 8 times more effective in systolic blood pressure reduction than a cocoa powder drink for the equivalent dose of flavanol. Cocoa flavanol consumption conclusively demonstrates a positive impact on cardiometabolic function; however, more research is needed to understand how best to consume it to maximize the benefit while avoiding excessive fat and sugar consumption.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quigley, B; Smith, C; La Riviere, P
2016-06-15
Purpose: To evaluate the resolution and sensitivity of XIL imaging using a surface radiance simulation based on optical diffusion and maximum likelihood expectation maximization (MLEM) image reconstruction. XIL imaging seeks to determine the distribution of luminescent nanophosphors, which could be used as nanodosimeters or radiosensitizers. Methods: The XIL simulation generated a homogeneous slab with optical properties similar to tissue. X-ray activated nanophosphors were placed at 1.0 cm depth in the tissue in concentrations of 10{sup −4} g/mL in two volumes of 10 mm{sup 3} with varying separations between each other. An analytical optical diffusion model determined the surface radiance frommore » the photon distributions generated at depth in the tissue by the nanophosphors. The simulation then determined the detected luminescent signal collected with a f/1.0 aperture lens and back-illuminated EMCCD camera. The surface radiance was deconvolved using a MLEM algorithm to estimate the nanophosphors distribution and the resolution. To account for both Poisson and Gaussian noise, a shifted Poisson imaging model was used in the deconvolution. The deconvolved distributions were fitted to a Gaussian after radial averaging to measure the full width at half maximum (FWHM) and the peak to peak distance between distributions was measured to determine the resolving power. Results: Simulated surface radiances for doses from 1mGy to 100 cGy were computed. Each image was deconvolved using 1000 iterations. At 1mGy, deconvolution reduced the FWHM of the nanophosphors distribution by 65% and had a resolving power is 3.84 mm. Decreasing the dose from 100 cGy to 1 mGy increased the FWHM by 22% but allowed for a dose reduction of a factor of 1000. Conclusion: Deconvolving the detected surface radiance allows for dose reduction while maintaining the resolution of the nanophosphors. It proves to be a useful technique in overcoming the resolution limitations of diffuse optical imaging in tissue. C. S. acknowledges support from the NIH National Institute of General Medical Sciences (Award number R25GM109439, Project Title: University of Chicago Initiative for Maximizing Student Development, IMSD). B. Q. and P. L. acknowledge support from NIH grant R01EB017293.« less
Hydroxyurea therapy requires HbF induction for clinical benefit in a sickle cell mouse model
Lebensburger, Jeffrey D.; Pestina, Tamara I.; Ware, Russell E.; Boyd, Kelli L.; Persons, Derek A.
2010-01-01
Hydroxyurea has proven clinical efficacy in patients with sickle cell disease. Potential mechanisms for the beneficial effects include fetal hemoglobin induction and the reduction of cell adhesive properties, inflammation and hypercoagulability. Using a murine model of sickle cell disease in which fetal hemoglobin induction does not occur, we evaluated whether hydroxyurea administration would still yield improvements in hematologic parameters and reduce end-organ damage. Animals given a maximally tolerated dose of hydroxyurea that resulted in significant reductions in the neutrophil and platelet counts showed no improvement in hemolytic anemia and end-organ damage compared to control mice. In contrast, animals having high levels of fetal hemoglobin due to gene transfer with a γ-globin lentiviral vector showed correction of anemia and organ damage. These data suggest that induction of fetal hemoglobin by hydroxyurea is an essential mechanism for its clinical benefits. PMID:20378564
Pre- and postnatal toxicity induced in guinea pigs by N-nitrosomethylurea.
Hasumi, K; Wilber, J H; Berkowitz, J; Wilber, R G; Epstein, S S
1975-10-01
Oral administration of N-nitrosomethylurea at maximally tolerated doses to guinea pigs on alternate days from days 34-58 of pregnancy induced prenatal toxicity, as evidenced by a high frequency of stillbirths and intrauterine growth retardation, and postnatal toxicity, as evidenced by stunting and progressive mortality. Similar administration of N-nitrosomethylurethane at maximally tolerated doses did not induce such toxic effects.
Phenytoin kinetics during pregnancy and the puerperium.
Knott, C; Williams, C P; Reynolds, F
1986-10-01
During pregnancy changes in maternal physiology and plasma composition may alter drug binding and dose requirements. We have measured plasma unbound and total phenytoin, and saliva concentrations at intervals in 11 pregnant epileptics. Plasma albumin concentrations were also measured in pregnant and non-pregnant women. Saliva phenytoin correlated closely with the plasma unbound concentrations (r = 0.98). The saliva:plasma (S:P) ratio, reflecting the free fraction, was variable during pregnancy but tended to increase to maximal values at delivery and return to non-pregnant values within 2-8 weeks thereafter. Plasma albumin concentrations correlated poorly with phenytoin binding. Binding in umbilical cord plasma appeared higher than that in maternal plasma and total fetal concentrations correlated closely with maternal plasma concentrations at delivery. No ill effects of phenytoin were detected in the newborn infant. During the third trimester phenytoin dose increments were necessary to maintain therapeutic concentrations. After delivery maternal saliva phenytoin concentrations rose, and dose reductions were necessary to avoid clinical symptoms of toxicity. It is therefore appropriate to monitor saliva phenytoin concentrations regularly both during pregnancy and the puerperium.
Ichihashi, Masamitsu; Ando, Hideya
2014-10-01
The young facial skin of children with a smooth healthy appearance changes over time to photoaged skin having mottled pigmentation, solar lentigines, wrinkles, dry and rough skin, leathery texture, and benign and malignant tumors after exposure to chronic, repeated solar radiation. The first sign of photoaging in Japanese subjects is usually solar lentigines appearing around 20 years of age on the face. Fine wrinkles can then appear after 30 years of age, and benign skin tumors, seborrhoeic keratoses, can occur after 35 years of age in sun-exposed skin. We theoretically calculated the maximal daily exposure time to solar radiation, which could prevent the development of photoaged skin until 60 and 80 years of age, based on published data of personal solar UVB doses in sun-exposed skin. One MED (minimal erythema dose) was determined to be 20 mJ/cm(2) , and 200 MED was used as the average yearly dose of Japanese children. Further, we hypothesized that the annual dose of Japanese adults is the same as that of the children. The cumulative UVB dose at 20 years of age was thus calculated to be 4000 MED, and 22 MED was used as the maximal daily UVB dose based on data measured in Kobe, located in the central area of Japan. We used the solar UVB dose from 10:00 a.m. to 14:00 p.m. which occupies 60% of the total daily UV dose, to obtain the maximal UVB per hour in a day, and calculated the maximal daily UV exposure time that would delay the onset of solar lentigines until 60 or 80 years of age. The mean daily sun exposure time to maintain healthy skin until 80 years of age in the summer was calculated to be 2.54 min (0.14 MED) for unprotected skin and 127 min with the use of a sunscreen of SPF (sun protection factor) of 50. In this study, we did not evaluate the photoaging effect of UVA radiation, but findings of the adverse effects of UVA radiation on the skin have accumulated in the last decade. Therefore, it will be important to estimate the maximal dose of solar UV radiation to retard the onset of photoaging based on an evaluation of both solar UVB and UVA in the future. Finally, we expect that this study may contribute to keeping Japanese and other types of skin young and healthy by limiting the exposure of the skin to solar radiation outdoors during the day. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
R. James Barbour; Jeremy Fried; Peter J. Daugherty; Glenn Christensen; Roger. Fight
2008-01-01
The FIA BioSum model was used to simulate three fire-hazard-reduction policies in an area comprising northern California, southwestern Oregon, and the east slopes of the Cascade Mountains in Oregon. The policy scenarios, all subject to a stand-scale fire-hazard-reduction effectiveness constraint, included maximize torching index improvement (Max TI), maximize net...
Radiation exposure of the radiologist's eye lens during CT-guided interventions.
Heusch, Philipp; Kröpil, Patric; Buchbender, Christian; Aissa, Joel; Lanzman, Rotem S; Heusner, Till A; Ewen, Klaus; Antoch, Gerald; Fürst, Günther
2014-02-01
In the past decade the number of computed tomography (CT)-guided procedures performed by interventional radiologists have increased, leading to a significantly higher radiation exposure of the interventionalist's eye lens. Because of growing concern that there is a stochastic effect for the development of lens opacification, eye lens dose reduction for operators and patients should be of maximal interest. To determine the interventionalist's equivalent eye lens dose during CT-guided interventions and to relate the results to the maximum of the recommended equivalent dose limit. During 89 CT-guided interventions (e.g. biopsies, drainage procedures, etc.) measurements of eye lens' radiation doses were obtained from a dedicated dosimeter system for scattered radiation. The sensor of the personal dosimeter system was clipped onto the side of the lead glasses which was located nearest to the CT gantry. After the procedure, radiation dose (µSv), dose rate (µSv/min) and the total exposure time (s) were recorded. For all 89 interventions, the median total exposure lens dose was 3.3 µSv (range, 0.03-218.9 µSv) for a median exposure time of 26.2 s (range, 1.1-94.0 s). The median dose rate was 13.9 µSv/min (range, 1.1-335.5 µSv/min). Estimating 50-200 CT-guided interventions per year performed by one interventionalist, the median dose of the eye lens of the interventional radiologist does not exceed the maximum of the ICRP-recommended equivalent eye lens dose limit of 20 mSv per year.
Pivonello, Rosario; Petersenn, Stephan; Newell-Price, John; Findling, James W; Gu, Feng; Maldonado, Mario; Trovato, Andrew; Hughes, Gareth; Salgado, Luiz R; Lacroix, André; Schopohl, Jochen; Biller, Beverly M K
2014-09-01
Signs and symptoms of Cushing's disease are associated with high burden of illness. In this analysis, we evaluated the effect of pasireotide treatment on signs and symptoms in patients with Cushing's disease. Phase III study with double-blind randomization of two pasireotide doses. Patients (n = 162) with persistent/recurrent or de novo Cushing's disease and urinary free cortisol (UFC) levels ≥1·5× upper limit of normal (ULN) were randomized to receive subcutaneous pasireotide (600/900 μg bid). At month 3, patients with UFC ≤2 × ULN and not exceeding the baseline value continued their randomized dose; all others received 300 μg bid uptitration. At month 6, patients could enter an open-label phase until month 12 with a maximal dose of 1200 μg bid. Changes in signs and symptoms of hypercortisolism over 12 months' treatment in patients still enroled in the study and with evaluable measurements were assessed in relation to degree of UFC control. Reductions in blood pressure were observed even without full UFC control and were greatest in patients who did not receive antihypertensive medications during the study. Significant reductions in total cholesterol and low-density lipoprotein (LDL)-cholesterol were observed in patients who achieved UFC control. Reductions in BMI, weight and waist circumference occurred during the study even without full UFC control. Adverse effects were typical of somatostatin analogues except for hyperglycaemia-related events, which were experienced by 72·8% of patients. In the largest Phase III study of medical therapy in Cushing's disease, significant improvements in signs and symptoms were seen during 12 months of pasireotide treatment, as UFC levels decreased. © 2014 John Wiley & Sons Ltd.
Comparison between neurectomy and botulinum toxin A injection for denervated skeletal muscle.
Tsai, Feng-Chou; Hsieh, Ming-Shium; Chou, Chih-Ming
2010-08-01
Neurectomy and botulinum toxin A (BoNT-A) injection cause denervated muscle atrophy, but questions remain about their clinical utility. We investigated time-series alterations of rat muscle weight, functional deficits, signaling pathways, and microscopic structures, to gain an understanding of the clinical implications. Between 2008 and 2009, the maximal calf circumference of patients for calf reduction either by neurectomy or BoNT-A injections were recorded for study. A rat skeletal muscle model was established through repeated or dose-adjusted BoNT-A injections and neurectomy. The survival, apoptosis pathways, functional deficits, and microscopic structures were investigated using Western blot, sciatic functional index (SFI), and transmission electron microscopy (TEM), respectively. The rat muscle weight ratio of the BoNT-A group had recovered to 89.3 +/- 3.8% by week 58, but it never recovered in the neurectomy group. Muscle weight reduction by BoNT-A not only depended on the dose, but additive effects were also obtained through repeated injections. Rat SFI demonstrated rapid recovery in both groups. Molecular expressions showed a coherent and biphasic pattern. p-Akt and apoptosis-inducing factor (AIF) were upregulated significantly, with a peak at 8 weeks in the neurectomy group (p < 0.01), but cleaved caspase-9 and caspase-3 showed no significant changes in either group. TEM findings showed irreversible and reversible inner-structure disruption and sarcomere discontinuity in the neurectomy and BoNT-A groups, respectively. We demonstrated that denervation induced lasting muscle weight and structural changes of different degrees. Muscle weight reduction by BoNT-A was related to frequency and dose. AIF-mediated caspase-independent apoptosis was significantly different for neurectomy and BoNT-A injection.
Güldner, C; Ningo, A; Voigt, J; Diogo, I; Heinrichs, J; Weber, R; Wilhelm, T; Fiebich, M
2013-03-01
More than 10 years ago, cone-beam-computed tomography (CBCT) was introduced in ENT radiology. Until now, the focus of research was to evaluate clinical limits of this technique. The aim of this work is the evaluation of specific dosages and the identification of potential optimization in the performance of CBCT of the paranasal sinuses. Based on different tube parameters (tube current, tube voltage, and rotation angles), images of the nose and the paranasal sinuses were taken on a phantom head with the Accu-I-tomo F17 (Morita, Kyoto, Japan). The dosages applied to the lens and parotid gland were measured with OSL dosimetry. The imaging quality was evaluated by independent observers. All datasets were reviewed according to a checklist of surgically important anatomic structures. Even for lowest radiation exposure (4 mA, 76 kV, 180°, computed tomography dosage index (CTDI) = 1.8 mGy), the imaging quality was sufficient. Of course a significant reduction of the imaging quality could be seen, so a reliable mean was set for 4 mA, 84 kV, and 180° rotation angle (CTDI = 2.4 mGy). In this combination, a reduction of 92 % in lens-dose and of 77 % of dosage at the parotid gland was observed in comparison to the maximal possible adjustments (8 mA, 90 kV, 360°, CTDI = 10.9 mGy). There is potential for optimization in CBCT. Changing the rotation angle (180° instead of 360°) leads to a dose reduction of 50 %. Furthermore from clinical point of view in case of chronic rhinosinusitis a relevant reduction of dosage is possible. Therefore, it is necessary to intensify the interdisciplinary discussion about the disease specifics required quality of imaging.
Effect of azelastine on sulphur dioxide induced impairment of ciliary motility in airway epithelium.
Tamaoki, J; Chiyotani, A; Sakai, N; Takeyama, K; Konno, K
1993-01-01
OBJECTIVE--The effect of azelastine on airway mucociliary transport function was studied by measuring ciliary motility of human bronchial epithelium in vitro with a photoelectric method. METHOD--Bronchial epithelial cells were obtained by fibreoptic bronchoscopy, mounted in a Rose chamber, and perfused with Krebs-Henseleit solution. The preparations were placed on a microscope stage equipped with an illuminator, and the variations of light intensity caused by ciliary beating were detected by a photometer. RESULTS--The addition of azelastine to the perfusate increased ciliary beat frequency (CBF) in a dose dependent manner without ciliary discoordination. The mean (SE) maximal increase from the baseline value and the concentration required to produce a half maximal effect were 27.0 (4.2)% and 9.2 x 10(-6) mol/l, respectively. Exposure of the cells to the perfusate containing 3 ppm sulphur dioxide rapidly decreased CBF by 59.2 (5.0)%, and was accompanied by a reduction in intracellular cyclic AMP levels from 38.1 (4.3) to 10.1 (2.4) pmol/mg protein. This effect was prevented by pretreatment of cells with azelastine in a dose dependent manner. CONCLUSIONS--Azelastine not only stimulates ciliary motility of airway epithelium and hence mucociliary transport function, but may also protect against sulphur dioxide induced ciliary dysfunction, probably by inhibiting intracellular cyclic AMP loss. PMID:8322244
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGarry, Conor K., E-mail: conor.mcgarry@belfasttrust.hscni.net; Bokrantz, Rasmus; RaySearch Laboratories, Stockholm
2014-10-01
Efficacy of inverse planning is becoming increasingly important for advanced radiotherapy techniques. This study’s aims were to validate multicriteria optimization (MCO) in RayStation (v2.4, RaySearch Laboratories, Sweden) against standard intensity-modulated radiation therapy (IMRT) optimization in Oncentra (v4.1, Nucletron BV, the Netherlands) and characterize dose differences due to conversion of navigated MCO plans into deliverable multileaf collimator apertures. Step-and-shoot IMRT plans were created for 10 patients with localized prostate cancer using both standard optimization and MCO. Acceptable standard IMRT plans with minimal average rectal dose were chosen for comparison with deliverable MCO plans. The trade-off was, for the MCO plans, managedmore » through a user interface that permits continuous navigation between fluence-based plans. Navigated MCO plans were made deliverable at incremental steps along a trajectory between maximal target homogeneity and maximal rectal sparing. Dosimetric differences between navigated and deliverable MCO plans were also quantified. MCO plans, chosen as acceptable under navigated and deliverable conditions resulted in similar rectal sparing compared with standard optimization (33.7 ± 1.8 Gy vs 35.5 ± 4.2 Gy, p = 0.117). The dose differences between navigated and deliverable MCO plans increased as higher priority was placed on rectal avoidance. If the best possible deliverable MCO was chosen, a significant reduction in rectal dose was observed in comparison with standard optimization (30.6 ± 1.4 Gy vs 35.5 ± 4.2 Gy, p = 0.047). Improvements were, however, to some extent, at the expense of less conformal dose distributions, which resulted in significantly higher doses to the bladder for 2 of the 3 tolerance levels. In conclusion, similar IMRT plans can be created for patients with prostate cancer using MCO compared with standard optimization. Limitations exist within MCO regarding conversion of navigated plans to deliverable apertures, particularly for plans that emphasize avoidance of critical structures. Minimizing these differences would result in better quality treatments for patients with prostate cancer who were treated with radiotherapy using MCO plans.« less
Subtle changes in brain functions produced by single doses of mevinphos (Phosdrin).
DOT National Transportation Integrated Search
1973-02-01
Mevinphos (Phosdrin) was found to inhibit the amplitude of hippocampal evoked potentials in unanesthetized squirrel monkeys with chronically indwelling electrodes. The threshold dose was 0.050 mg/kg and the maximal dose studied was 0.200 mg/kg. Doses...
Aziz, Muhammad Hammad; Schneider, Frank; Clausen, Sven; Blank, Elena; Herskind, Carsten; Afzal, Muhammad; Wenz, Frederik
2011-12-16
Radiation induced secondary cancers are a rare but severe late effect after breast conserving therapy. Intraoperative radiotherapy (IORT) is increasingly used during breast conserving surgery. The purpose of this analysis was to estimate secondary cancer risks after IORT compared to other modalities of breast radiotherapy (APBI - accelerated partial breast irradiation, EBRT - external beam radiotherapy). Computer-tomography scans of an anthropomorphic phantom were acquired with an INTRABEAM IORT applicator (diameter 4 cm) in the outer quadrant of the breast and transferred via DICOM to the treatment planning system. Ipsilateral breast, contralateral breast, ipsilateral lung, contralateral lung, spine and heart were contoured. An INTRABEAM source (50 kV) was defined with the tip of the drift tube at the center of the spherical applicator. A dose of 20 Gy at 0 mm depth from the applicator surface was prescribed for IORT and 34 Gy (5 days × 2 × 3.4 Gy) at 10 mm depth for APBI. For EBRT a total dose of 50 Gy in 2 Gy fractions was planned using two tangential fields with wedges. The mean and maximal doses, DVHs and volumes receiving more than 0.1 Gy and 4 Gy of organs at risk (OAR) were calculated and compared. The life time risk for secondary cancers was estimated according to NCRP report 116. IORT delivered the lowest maximal doses to contralateral breast (< 0.3 Gy), ipsilateral (1.8 Gy) and contralateral lung (< 0.3 Gy), heart (1 Gy) and spine (< 0.3 Gy). In comparison, maximal doses for APBI were 2-5 times higher. EBRT delivered a maximal dose of 10.4 Gy to the contralateral breast and 53 Gy to the ipsilateral lung. OAR volumes receiving more than 4 Gy were 0% for IORT, < 2% for APBI and up to 10% for EBRT (ipsilateral lung). The estimated risk for secondary cancer in the respective OAR is considerably lower after IORT and/or APBI as compared to EBRT. The calculations for maximal doses and volumes of OAR suggest that the risk of secondary cancer induction after IORT is lower than compared to APBI and EBRT.
Fuel Efficient Strategies for Reducing Contrail Formations in United States Air Space
NASA Technical Reports Server (NTRS)
Sridhar, Banavar; Chen, Neil Y.; Ng, Hok K.
2010-01-01
This paper describes a class of strategies for reducing persistent contrail formation in the United States airspace. The primary objective is to minimize potential contrail formation regions by altering the aircraft's cruising altitude in a fuel-efficient way. The results show that the contrail formations can be reduced significantly without extra fuel consumption and without adversely affecting congestion in the airspace. The contrail formations can be further reduced by using extra fuel. For the day tested, the maximal reduction strategy has a 53% contrail reduction rate. The most fuel-efficient strategy has an 8% reduction rate with 2.86% less fuel-burnt compared to the maximal reduction strategy. Using a cost function which penalizes extra fuel consumed while maximizing the amount of contrail reduction provides a flexible way to trade off between contrail reduction and fuel consumption. It can achieve a 35% contrail reduction rate with only 0.23% extra fuel consumption. The proposed fuel-efficient contrail reduction strategy provides a solution to reduce aviation-induced environmental impact on a daily basis.
Inhibition of neutrophil and monocyte recruitment by endogenous and exogenous lipocortin 1
Getting, Stephen J; Flower, Roderick J; Perretti, Mauro
1997-01-01
The role played by endogenous lipocortin 1 in the anti-migratory action exerted by dexamethasone (Dex) on monocyte recruitment in an in vivo model of acute inflammation was investigated by use of several neutralizing polyclonal antibodies raised against lipocortin 1 or a lipocortin 1-derived N-terminus peptide (peptide Ac2-26). The efficacy of peptide Ac2-26 in inhibiting monocyte and polymorphonuclear leucocyte (PMN) recruitment was also tested.Intraperitoneal (i.p.) injection of zymosan A (1 mg) produced a time-dependent cell accumulation into mouse peritoneal cavities which followed a typical profile of acute inflammation: PMN influx was maximal at 4 h post-zymosan (between 15 and 20×106 cells per mouse), and this was followed by an accumulation of monocytes which peaked at the 24 h time-point (between 10 and 15×106 cells per mouse).Dex administration to mice reduced zymosan-induced 4 h PMN infiltration and 24 h monocyte accumulation with similar efficacy: approximately 50% of inhibition of recruitment of both cell types was achieved at the dose of 30 μg per mouse (∼1 mg kg−1, subcutaneously (s.c.)). Maximal inhibitions of 64% and 67% on PMN and monocyte recruitment, respectively, were measured after a dose of 100 μg per mouse (∼3 mg kg−1, s.c.).Dex (30 μg s.c.) inhibited monocyte (53%) and PMN (69%) accumulation in response to zymosan application in mice which had been treated with a non-immune sheep serum (50 μl s.c.). In contrast, the steroid was no longer active in reducing cell accumulation in mice which had been passively immunized against full length human recombinant lipocortin 1 (serum LCS3), or against lipocortin 1 N-terminus peptide.Treatment of mice with vinblastine (1 mg kg−1, intravenously (i.v.)) produced a remarkable leucopenia as assessed 24 h after administration. This was accompanied by a 60% reduction in 4 h-PMN influx, and by a 27% reduction in 24 h-monocyte accumulation, measured after zymosan administration. The inhibitory effect of Dex on monocyte recruitment was not significantly modified in vinblastine-treated mice, with 36% and 57% of inhibition calculated at the dose of 30 μg Dex, and 70% and 60% of inhibition at 100 μg Dex, in vehicle- and vinblastine-treated mice, respectively.Treatment of mice with peptide Ac2-26 dose-dependently attenuated PMN influx at 4 h post-zymosan with a significant effect at 100 μg per mouse (45% of inhibition, n=9, P<0.05) and a maximal effect of 61% inhibition at the highest dose tested of 200 μg s.c. (n=14, P<0.05). No effect of peptide Ac2-26 (200 μg s.c.) was seen on zymosan-induced 24 h monocyte recruitment. In contrast, administration of 200 μg peptide Ac2-26 every 6 h was effective in reducing the number of monocytes harvested from the inflamed peritoneal cavities at 24 h post-zymosan: 9.40±0.58×106 monocytes per mouse (n=13) and 5.74±0.34 monocytes per mouse (n=14) in vehicle- and peptide Ac2-26-treated mice, respectively (P<0.05).Finally, peptide Ac2-26 produced a concentration-dependent inhibition of the rate of phagocytosis of mouse resident peritoneal macrophages as measured by flow cytometry, with a maximal reduction of 34% at the highest concentration tested of 100 μg ml−1 (n=8 experiments performed in duplicate; P<0.05).In conclusion, this study suggests that in vivo monocyte recruitment during acute inflammation is, at least in part, under the negative modulatory control of endogenous lipocortin 1 (as seen after administration of Dex by using the specific antisera) and exogenous lipocortin 1 mimetics (as observed with peptide Ac2-26). In addition to the neutrophil, we can now propose that the monocyte also can be a target for the in vivo anti-inflammatory action of lipocortin 1. PMID:9134220
Adams, Julie E; O'Brien, Virginia; Magnusson, Erik; Rosenstein, Benjamin; Nuckley, David J
2018-01-01
Therapy programs to treat thumb carpometacarpal (CMC) arthritis may engage selective activation and reeducation of thenar muscles, particularly the first dorsal interosseous (FDI) and opponens pollicis (OP) to reduce subluxation of the joint. We describe the effect of simulated selective activation of the FDI and OP muscles upon radiographic subluxation of the thumb CMC joint. In a cadaver model of CMC subluxation, loads were applied to the FDI, the OP, and then concomitantly at 0%, 25%, 50%, 75%, and 100% maximal loads and radial subluxation of the joint and reduction in subluxation was measured. Selective activation of the OP, alone, improved the subluxation ratio (SR) in a dose-dependent manner. Selective activation of FDI, alone, demonstrated minimal effects on SR. Concomitant activation of OP and FDI improved the SR across all loading states, and activation of 75% and greater, when compared with FDI activation alone, resulted in a statistically significant improvement in SR to within 10% of the presubluxed joint. Concomitant activation of the FDI and OP acts to reduce subluxation of the thumb CMC joint in a dose-dependent fashion. The OP is likely the predominant reducing force. Hand therapy programs that focus on selective strengthening programs likely function in part to encourage patients to activate the easily palpable and easily understood FDI. Concomitant coactivation of the OP may be the major reducing force to elicit clinical and radiographic reduction of subluxation, improved thumb positioning, and reduction of pain and arthritic symptoms.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu Weigang; Graff, Pierre; Boettger, Thomas
2011-04-15
Purpose: To develop a spatially encoded dose difference maximal intensity projection (DD-MIP) as an online patient dose evaluation tool for visualizing the dose differences between the planning dose and dose on the treatment day. Methods: Megavoltage cone-beam CT (MVCBCT) images acquired on the treatment day are used for generating the dose difference index. Each index is represented by different colors for underdose, acceptable, and overdose regions. A maximal intensity projection (MIP) algorithm is developed to compress all the information of an arbitrary 3D dose difference index into a 2D DD-MIP image. In such an algorithm, a distance transformation is generatedmore » based on the planning CT. Then, two new volumes representing the overdose and underdose regions of the dose difference index are encoded with the distance transformation map. The distance-encoded indices of each volume are normalized using the skin distance obtained on the planning CT. After that, two MIPs are generated based on the underdose and overdose volumes with green-to-blue and green-to-red lookup tables, respectively. Finally, the two MIPs are merged with an appropriate transparency level and rendered in planning CT images. Results: The spatially encoded DD-MIP was implemented in a dose-guided radiotherapy prototype and tested on 33 MVCBCT images from six patients. The user can easily establish the threshold for the overdose and underdose. A 3% difference between the treatment and planning dose was used as the threshold in the study; hence, the DD-MIP shows red or blue color for the dose difference >3% or {<=}3%, respectively. With such a method, the overdose and underdose regions can be visualized and distinguished without being overshadowed by superficial dose differences. Conclusions: A DD-MIP algorithm was developed that compresses information from 3D into a single or two orthogonal projections while hinting the user whether the dose difference is on the skin surface or deeper.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wells, P.G.; Zubovits, J.T.; Wong, S.T.
1989-02-01
Teratogenicity of the anticonvulsant drug phenytoin is thought to involve its bioactivation by cytochromes P-450 to a reactive arene oxide intermediate. We hypothesized that phenytoin also may be bioactivated to a teratogenic free radical intermediate by another enzymatic system, prostaglandin synthetase. To evaluate the teratogenic contribution of this latter pathway, an irreversible inhibitor of prostaglandin synthetase, acetylsalicylic acid (ASA), 10 mg/kg intraperitoneally (ip), was administered to pregnant CD-1 mice at 9:00 AM on Gestational Days 12 and 13, 2 hr before phenytoin, 65 mg/kg ip. Other groups were pretreated 2 hr prior to phenytoin administration with either the antioxidant caffeicmore » acid or the free radical spin trapping agent alpha-phenyl-N-t-butylnitrone (PBN). Caffeic acid and PBN were given ip in doses that respectively were up to 1.0 to 0.05 molar equivalents to the dose of phenytoin. Dams were killed on Day 19 and the fetuses were assessed for teratologic anomalies. A similar study evaluated the effect of ASA on the in vivo covalent binding of radiolabeled phenytoin administered on Day 12, in which case dams were killed 24 hr later on Day 13. ASA pretreatment produced a 50% reduction in the incidence of fetal cleft palates induced by phenytoin (p less than 0.05), without significantly altering the incidence of resorptions or mean fetal body weight. Pretreatment with either caffeic acid or PBN resulted in dose-related decreases in the incidence of fetal cleft palates produced by phenytoin, with maximal respective reductions of 71 and 82% at the highest doses of caffeic acid and PBN (p less than 0.05).« less
Factor XII full and partial null in rat confers robust antithrombotic efficacy with no bleeding.
Cai, Tian-Quan; Wu, Weizhen; Shin, Myung K; Xu, Yiming; Jochnowitz, Nina; Zhou, Yuchen; Hoos, Lizbeth; Bentley, Ross; Strapps, Walter; Thankappan, Anil; Metzger, Joseph M; Ogletree, Martin L; Tadin-Strapps, Marija; Seiffert, Dietmar A; Chen, Zhu
2015-12-01
This report aims at exploring quantitatively the relationship between FXII inhibition and thromboprotection. FXII full and partial null in rats were established via zinc finger nuclease-mediated knockout and siRNA-mediated knockdown, respectively. The rats were subsequently characterized in thrombosis and hemostasis models. Knockout rats exhibited complete thromboprotection in both the arteriovenous shunt model (∼100% clot weight reduction) and the FeCl3-induced arterial thrombosis model (no reduction in blood flow), without any increase in cuticle bleeding time compared with wild-type control rats. Ex-vivo aPTT and the ellagic acid-triggered thrombin generation assay (TGA) exhibited anticoagulant changes. In contrast, ex-vivo PT or high tissue factor-triggered TGA was indistinguishable from control. Rats receiving single doses (0, 0.01, 0.03, 0.1, 0.3, 1 mg/kg) of FXII siRNA exhibited dose-dependent knockdown in liver FXII mRNA and plasma FXII protein (95 and 99%, respectively, at 1 mg/kg) at day 7 post dosing. FXII knockdown was associated with dose-dependent thromboprotection (maximal efficacy achieved with 1 mg/kg in both models) and negligible change in cuticle bleeding times. Ex-vivo TGA triggered with low-level (0.5 μmol/l) ellagic acid tracked best with the knockdown levels and efficacy. Our findings confirm and extend literature reports of an attractive benefit-to-risk profile of targeting FXII for antithrombotic therapies. Titrating of FXII is instructive for its pharmacological inhibition. The knockout rat is valuable for evaluating both mechanism-based safety concerns and off-target effects of FXII(a) inhibitors. Detailed TGA analyses will inform on optimal trigger conditions in studying pharmacodynamic effects of FXII(a) inhibition.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gang, G; Siewerdsen, J; Stayman, J
Purpose: There has been increasing interest in integrating fluence field modulation (FFM) devices with diagnostic CT scanners for dose reduction purposes. Conventional FFM strategies, however, are often either based on heuristics or the analysis of filtered-backprojection (FBP) performance. This work investigates a prospective task-driven optimization of FFM for model-based iterative reconstruction (MBIR) in order to improve imaging performance at the same total dose as conventional strategies. Methods: The task-driven optimization framework utilizes an ultra-low dose 3D scout as a patient-specific anatomical model and a mathematical formation of the imaging task. The MBIR method investigated is quadratically penalized-likelihood reconstruction. The FFMmore » objective function uses detectability index, d’, computed as a function of the predicted spatial resolution and noise in the image. To optimize performance throughout the object, a maxi-min objective was adopted where the minimum d’ over multiple locations is maximized. To reduce the dimensionality of the problem, FFM is parameterized as a linear combination of 2D Gaussian basis functions over horizontal detector pixels and projection angles. The coefficients of these bases are found using the covariance matrix adaptation evolution strategy (CMA-ES) algorithm. The task-driven design was compared with three other strategies proposed for FBP reconstruction for a calcification cluster discrimination task in an abdomen phantom. Results: The task-driven optimization yielded FFM that was significantly different from those designed for FBP. Comparing all four strategies, the task-based design achieved the highest minimum d’ with an 8–48% improvement, consistent with the maxi-min objective. In addition, d’ was improved to a greater extent over a larger area within the entire phantom. Conclusion: Results from this investigation suggests the need to re-evaluate conventional FFM strategies for MBIR. The task-based optimization framework provides a promising approach that maximizes imaging performance under the same total dose constraint.« less
Ikuta, Ichiro; Warden, Graham I.; Andriole, Katherine P.; Khorasani, Ramin
2014-01-01
Purpose To test the hypothesis that patient size can be accurately calculated from axial computed tomographic (CT) images, including correction for the effects of anatomy truncation that occur in routine clinical CT image reconstruction. Materials and Methods Institutional review board approval was obtained for this HIPAA-compliant study, with waiver of informed consent. Water-equivalent diameter (DW) was computed from the attenuation-area product of each image within 50 adult CT scans of the thorax and of the abdomen and pelvis and was also measured for maximal field of view (FOV) reconstructions. Linear regression models were created to compare DW with the effective diameter (Deff) used to select size-specific volume CT dose index (CTDIvol) conversion factors as defined in report 204 of the American Association of Physicists in Medicine. Linear regression models relating reductions in measured DW to a metric of anatomy truncation were used to compensate for the effects of clinical image truncation. Results In the thorax, DW versus Deff had an R2 of 0.51 (n = 200, 50 patients at four anatomic locations); in the abdomen and pelvis, R2 was 0.90 (n = 150, 50 patients at three anatomic locations). By correcting for image truncation, the proportion of clinically reconstructed images with an extracted DW within ±5% of the maximal FOV DW increased from 54% to 90% in the thorax (n = 3602 images) and from 95% to 100% in the abdomen and pelvis (6181 images). Conclusion The DW extracted from axial CT images is a reliable measure of patient size, and varying degrees of clinical image truncation can be readily corrected. Automated measurement of patient size combined with CT radiation exposure metrics may enable patient-specific dose estimation on a large scale. © RSNA, 2013 PMID:24086075
Pharmacokinetic Correlates of the Effects of a Heroin Vaccine on Heroin Self-Administration in Rats
Raleigh, Michael D.; Pentel, Paul R.; LeSage, Mark G.
2014-01-01
The purpose of this study was to evaluate the effects of a morphine-conjugate vaccine (M-KLH) on the acquisition, maintenance, and reinstatement of heroin self-administration (HSA) in rats, and on heroin and metabolite distribution during heroin administration that approximated the self-administered dosing rate. Vaccination with M-KLH blocked heroin-primed reinstatement of heroin responding. Vaccination also decreased HSA at low heroin unit doses but produced a compensatory increase in heroin self-administration at high unit doses. Vaccination shifted the heroin dose-response curve to the right, indicating reduced heroin potency, and behavioral economic demand curve analysis further confirmed this effect. In a separate experiment heroin was administered at rates simulating heroin exposure during HSA. Heroin and its active metabolites, 6-acetylmorphine (6-AM) and morphine, were retained in plasma and metabolite concentrations were reduced in brain in vaccinated rats compared to controls. Reductions in 6-AM concentrations in brain after vaccination were consistent with the changes in HSA rates accompanying vaccination. These data provide evidence that 6-AM is the principal mediator of heroin reinforcement, and the principal target of the M-KLH vaccine, in this model. While heroin vaccines may have potential as therapies for heroin addiction, high antibody to drug ratios appear to be important for obtaining maximal efficacy. PMID:25536404
DOE Office of Scientific and Technical Information (OSTI.GOV)
Magallanes, L., E-mail: lorena.magallanes@med.uni-heidelberg.de; Rinaldi, I., E-mail: ilaria.rinaldi@med.uni-heidelberg.de; Brons, S., E-mail: stephan.brons@med.uni-heidelberg.de
External beam radiotherapy techniques have the common aim to maximize the radiation dose to the target while sparing the surrounding healthy tissues. The inverted and finite depth-dose profile of ion beams (Bragg peak) allows for precise dose delivery and conformai dose distribution. Furthermore, increased radiobiological effectiveness of ions enhances the capability to battle radioresistant tumors. Ion beam therapy requires a precise determination of the ion range, which is particularly sensitive to range uncertainties. Therefore, novel imaging techniques are currently investigated as a tool to improve the quality of ion beam treatments. Approaches already clinically available or under development are basedmore » on the detection of secondary particles emitted as a result of nuclear reactions (e.g., positron-annihilation or prompt gammas, charged particles) or transmitted high energy primary ion beams. Transmission imaging techniques make use of the beams exiting the patient, which have higher initial energy and lower fluence than the therapeutic ones. At the Heidelberg Ion Beam Therapy Center, actively scanned energetic proton and carbon ion beams provide an ideal environment for the investigation of ion-based radiography and tomography. This contribution presents the rationale of ion beam therapy, focusing on the role of ion-based transmission imaging methods towards the reduction of range uncertainties and potential improvement of treatment planning.« less
Dirscherl, Thomas; Rickhey, Mark; Bogner, Ludwig
2012-02-01
A biologically adaptive radiation treatment method to maximize the TCP is shown. Functional imaging is used to acquire a heterogeneous dose prescription in terms of Dose Painting by Numbers and to create a patient-specific IMRT plan. Adapted from a method for selective dose escalation under the guidance of spatial biology distribution, a model, which translates heterogeneously distributed radiobiological parameters into voxelwise dose prescriptions, was developed. At the example of a prostate case with (18)F-choline PET imaging, different sets of reported values for the parameters were examined concerning their resulting range of dose values. Furthermore, the influence of each parameter of the linear-quadratic model was investigated. A correlation between PET signal and proliferation as well as cell density was assumed. Using our in-house treatment planning software Direct Monte Carlo Optimization (DMCO), a treatment plan based on the obtained dose prescription was generated. Gafchromic EBT films were irradiated for evaluation. When a TCP of 95% was aimed at, the maximal dose in a voxel of the prescription exceeded 100Gy for most considered parameter sets. One of the parameter sets resulted in a dose range of 87.1Gy to 99.3Gy, yielding a TCP of 94.7%, and was investigated more closely. The TCP of the plan decreased to 73.5% after optimization based on that prescription. The dose difference histogram of optimized and prescribed dose revealed a mean of -1.64Gy and a standard deviation of 4.02Gy. Film verification showed a reasonable agreement of planned and delivered dose. If the distribution of radiobiological parameters within a tumor is known, this model can be used to create a dose-painting by numbers plan which maximizes the TCP. It could be shown, that such a heterogeneous dose distribution is technically feasible. Copyright © 2012. Published by Elsevier GmbH.
Simunkova, Katerina; Jovanovic, Nevena; Rostrup, Espen; Methlie, Paal; Øksnes, Marianne; Nilsen, Roy Miodini; Hennø, Hanne; Tilseth, Mira; Godang, Kristin; Kovac, Ana; Løvås, Kristian; Husebye, Eystein S
2016-01-01
Many patients with primary adrenal insufficiency (Addison's disease) take extra doses of glucocorticoids during stressful events, but a benefit has not been demonstrated in controlled trials. Here, we investigated the effects of a pre-exercise hydrocortisone dose on cardiorespiratory, hormonal and metabolic parameters in response to short-term strenuous physical activity. This was a randomized placebo-controlled, two-week cross-over clinical trial. Ten women with Addison's disease and 10 age-matched healthy females participated in the study. All women in the study underwent maximal incremental exercise testing. A stress dose of 10 mg hydrocortisone or placebo was given 1 h prior to exercise on two occasions. Blood samples were drawn before, and 0, 15 and 30 min post exercise. Oxygen uptake, maximal aerobic capacity, endocrine and metabolic responses to physical activity, as well as health status by questionnaires were evaluated. Maximal aerobic capacity and duration of exercise were significantly lower in patients than in healthy subjects and did not improve with the treatment. After an extra hydrocortisone dose serum cortisol was significantly higher than in the healthy subjects (P<0.001). Post-exercise glucose and adrenaline levels were significantly lower and free fatty acids insignificantly higher in patients irrespective of stress dose. Stress dosing did not alter other metabolic or hormonal parameters or quality of life after the exercise. The patients did not benefit from an extra dose of hydrocortisone in short strenuous exercise. Stress dosing may not be justified in this setting. Whether stress dosing is beneficial in other types of physical activity will have to be examined further. © 2016 European Society of Endocrinology.
Mydlo, J H; Volpe, M A; Macchia, R J
2000-07-01
Intraurethral alprostadil and oral sildenafil are useful in selected patients. However, there continues to be a significant treatment failure rate. Since their mechanisms of action are different, we wanted to evaluate the effectiveness of combination therapy. Of 214 patients treated for erectile dysfunction (ED), 65 were not fully satisfied with the firmness of their erections via monotherapy. Responses were evaluated using the International Index for Erectile Function (IIEF) questionnaire before and after treatment. Group I consisted of 33 patients who tried maximal dose intraurethral alprostadil monotherapy initially, followed by the maximal dose of sildenafil monotherapy, and were still unsatisfied. Group II consisted of 32 patients who tried the maximal dose sildenafil monotherapy initially, followed by the maximal dose of alprostadil monotherapy, and were also unsatisfied. There 65 patients then underwent combination therapy. 60 out of the 65 patients stated they were satisfied with combination therapy. Questionnaire scores for erectile function were 23.1+/-2.0 (114%) for combination therapy vs. 19.2+/-1.8 (77%) and 15.2+/-1.6 (41%) for sildenafil and alprostadil monotherapies (p<0.05). There were no significant differences in responses between the two groups. The men also reported improvement in intercourse and overall satisfaction. Combination therapy may be an option for motivated patients who have a suboptimal response from monotherapy.
Bradycardia and Hypothermia Complicating Azithromycin Treatment.
Benn, Kerri; Salman, Sam; Page-Sharp, Madhu; Davis, Timothy M E; Buttery, Jim P
2017-08-11
BACKGROUND Azithromycin is a macrolide antibiotic widely used to treat respiratory, urogenital, and other infections. Gastrointestinal upset, headache, and dizziness are common adverse effects, and prolongation of the rate-corrected electrocardiographic QT interval and malignant arrhythmias have been reported. There are rare reports of bradycardia and hypothermia but not in the same patient. CASE REPORT A 4-year-old boy given intravenous azithromycin as part of treatment for febrile neutropenia complicating leukemia chemotherapy developed hypothermia (rectal temperature 35.2°C) and bradycardia (65 beats/minute) after the second dose, which resolved over several days post-treatment, consistent with persistence of high tissue azithromycin concentrations relative to those in plasma. A sigmoid Emax pharmacokinetic/pharmacodynamic model suggested a maximal azithromycin-associated reduction in heart rate of 23 beats/minute. Monitoring for these potential adverse effects should facilitate appropriate supportive care in similar cases. CONCLUSIONS Recommended azithromycin doses can cause at least moderate bradycardia and hypothermia in vulnerable pediatric patients, adverse effects that should prompt appropriate monitoring and which may take many days to resolve.
Test of 3D CT reconstructions by EM + TV algorithm from undersampled data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evseev, Ivan; Ahmann, Francielle; Silva, Hamilton P. da
2013-05-06
Computerized tomography (CT) plays an important role in medical imaging for diagnosis and therapy. However, CT imaging is connected with ionization radiation exposure of patients. Therefore, the dose reduction is an essential issue in CT. In 2011, the Expectation Maximization and Total Variation Based Model for CT Reconstruction (EM+TV) was proposed. This method can reconstruct a better image using less CT projections in comparison with the usual filtered back projection (FBP) technique. Thus, it could significantly reduce the overall dose of radiation in CT. This work reports the results of an independent numerical simulation for cone beam CT geometry withmore » alternative virtual phantoms. As in the original report, the 3D CT images of 128 Multiplication-Sign 128 Multiplication-Sign 128 virtual phantoms were reconstructed. It was not possible to implement phantoms with lager dimensions because of the slowness of code execution even by the CORE i7 CPU.« less
Opioid receptor mediated anticonvulsant effect of pentazocine.
Khanna, N; Khosla, R; Kohli, J
1998-01-01
Intraperitoneal (i.p.) administration of (+/-) pentazocine (10, 30 & 50 mg/kg), a Sigma opioid agonist, resulted in a dose dependent anticonvulsant action against maximal electroshock seizures in mice. This anticonvulsant effect of pentazocine was not antagonized by both the doses of naloxone (1 and 10 mg/kg) suggesting thereby that its anticonvulsant action is probably mediated by Sigma opiate binding sites. Its anticonvulsant effect was potentiated by both the anticonvulsant drugs viz. diazepam and diphenylhydantoin. Morphine, mu opioid agonist, on the other hand, failed to protect the animals against maximal electroshock seizures when it was given in doses of 10-40 mg/kg body wt.
Grimsrud, K N; Ait-Oudhia, S; Durbin-Johnson, B P; Rocke, D M; Mama, K R; Rezende, M L; Stanley, S D; Jusko, W J
2015-02-01
The present study characterizes the pharmacokinetic (PK) and pharmacodynamic (PD) relationships of the α2-adrenergic receptor agonists detomidine (DET), medetomidine (MED) and dexmedetomidine (DEX) in parallel groups of horses from in vivo data after single bolus doses. Head height (HH), heart rate (HR), and blood glucose concentrations were measured over 6 h. Compartmental PK and minimal physiologically based PK (mPBPK) models were applied and incorporated into basic and extended indirect response models (IRM). Population PK/PD analysis was conducted using the Monolix software implementing the stochastic approximation expectation maximization algorithm. Marked reductions in HH and HR were found. The drug concentrations required to obtain inhibition at half-maximal effect (IC50 ) were approximately four times larger for DET than MED and DEX for both HH and HR. These effects were not gender dependent. Medetomidine had a greater influence on the increase in glucose concentration than DEX. The developed models demonstrate the use of mechanistic and mPBPK/PD models for the analysis of clinically obtainable in vivo data. © 2014 John Wiley & Sons Ltd.
Grimsrud, K. N.; Ait-Oudhia, S.; Durbin-Johnson, B. P.; Rocke, D. M.; Mama, K. R.; Rezende, M. L.; Stanley, S. D.; Jusko, W. J.
2014-01-01
The present study characterizes the pharmacokinetic (PK) and pharmacodynamic (PD) relationships of the α2-adrenergic receptor agonists detomidine (DET), medetomidine (MED) and dexmedetomidine (DEX) in parallel groups of horses from in vivo data after single bolus doses. Head height (HH), heart rate (HR), and blood glucose concentrations were measured over 6 h. Compartmental PK and minimal physiologically based PK (mPBPK) models were applied and incorporated into basic and extended indirect response models (IRM). Population PK/PD analysis was conducted using the Monolix software implementing the stochastic approximation expectation maximization algorithm. Marked reductions in HH and HR were found. The drug concentrations required to obtain inhibition at half-maximal effect (IC50) were approximately four times larger for DET than MED and DEX for both HH and HR. These effects were not gender dependent. Medetomidine had a greater influence on the increase in glucose concentration than DEX. The developed models demonstrate the use of mechanistic and mPBPK/PD models for the analysis of clinically obtainable in vivo data. PMID:25073816
Six steps to a successful dose-reduction strategy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bennett, M.
1995-03-01
The increased importance of demonstrating achievement of the ALARA principle has helped produce a proliferation of dose-reduction ideas. Across a company there may be many dose-reduction items being pursued in a variety of areas. However, companies have a limited amount of resource and, therefore, to ensure funding is directed to those items which will produce the most benefit and that all areas apply a common policy, requires the presence of a dose-reduction strategy. Six steps were identified in formulating the dose-reduction strategy for Rolls-Royce and Associates (RRA): (1) collating the ideas; (2) quantitatively evaluating them on a common basis; (3)more » prioritizing the ideas in terms of cost benefit, (4) implementation of the highest priority items; (5) monitoring their success; (6) periodically reviewing the strategy. Inherent in producing the dose-reduction strategy has been a comprehensive dose database and the RRA-developed dose management computer code DOMAIN, which allows prediction of dose rates and dose. The database enabled high task dose items to be identified, assisted in evaluating dose benefits, and monitored dose trends once items had been implemented. The DOMAIN code was used both in quantifying some of the project dose benefits and its results, such as dose contours, used in some of the dose-reduction items themselves. In all, over fifty dose-reduction items were evaluated in the strategy process and the items which will give greatest benefit are being implemented. The strategy has been successful in giving renewed impetus and direction to dose-reduction management.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fogh, Shannon; Machtay, Mitchell; Werner-Wasik, Maria
Purpose: Based on preclinical data indicating the radiosensitizing potential of epothilone B, the present study was designed to evaluate the toxicity and response rate of patupilone, an epothilone B, with concurrent radiotherapy (RT) for the treatment of central nervous system malignancies. Methods and Materials: The present Phase I study evaluated the toxicities associated with patupilone combined with RT to establish the maximal tolerated dose. Eligible patients had recurrent gliomas (n = 10) primary (n = 5) or metastatic (n = 17) brain tumors. Dose escalation occurred if no dose-limiting toxicities, defined as any Grade 4-5 toxicity or Grade 3 toxicitymore » requiring hospitalization, occurred during treatment. Results: Of 14 patients, 5 were treated with weekly patupilone at 1.5 mg/m{sup 2}, 4 at 2.0 mg/m{sup 2}, 4 at 2.5 mg/m{sup 2}, and 1 at 4 mg/m{sup 2}. Of 18 patients, 7 were treated in the 6-mg/m{sup 2} group, 6 in the 8-mg/m{sup 2} group, and 5 in the 10-mg/m{sup 2} group. Primary central nervous system malignancies received RT to a median dose of 60 Gy. Central nervous system metastases received whole brain RT to a median dose of 37.4 Gy, and patients with recurrent gliomas underwent stereotactic RT to a median dose of 37.5 Gy. One dose-limiting toxicity (pneumonia) was observed in group receiving 8-mg/m{sup 2} every 3 weeks. At the subsequent dose level (10 mg/m{sup 2}), two Grade 4 dose-limiting toxicities occurred (renal failure and pulmonary hemorrhage); thus, 8 mg/m{sup 2} every 3 weeks was the maximal tolerated dose and the recommended Phase II dose. Conclusion: Combined with a variety of radiation doses and fractionation schedules, concurrent patupilone was well tolerated and safe, with a maximal tolerated dose of 8 mg/m{sup 2} every 3 weeks.« less
Firsov, Alexander A; Vostrov, Sergey N; Lubenko, Irene Yu; Arzamastsev, Alexander P; Portnoy, Yury A; Zinner, Stephen H
2004-07-01
To compare the kinetics of killing/regrowth of differentially susceptible clinical isolates of Staphylococcus aureus exposed to ABT492 and levofloxacin and to explore their relative abilities to prevent the selection of resistant mutants. Three clinical isolates of S. aureus--including two ciprofloxacin-susceptible S. aureus, 201 and 480--and a ciprofloxacin-resistant S. aureus 866, were exposed to clinically achievable ratios of area under the curve (AUC) to MIC in a dynamic model that simulated human pharmacokinetics of ABT492 (400 mg) and levofloxacin (500 mg) as a single dose. In addition, S. aureus 201 was exposed to single and multiple doses of ABT492 and levofloxacin (both once daily for 3 days) over wide ranges of 24 h AUC/MIC (AUC24/MIC) including clinically achievable AUC24/MIC ratios. With each isolate, ABT492 at clinically achievable AUC/MICs produced greater anti-staphylococcal effects than levofloxacin. Areas between the control growth and the time--kill curves (ABBC in single dose simulations and the sum of ABBCs determined after the first, second and third dosing in multiple dose simulations--ABBC(1+2+3)) were higher with ABT492 than levofloxacin. Moreover, at comparable AUC/MICs and AUC24/MICs, the maximal reductions in the starting inoculum of ABT492-exposed S. aureus were more pronounced than with levofloxacin. Loss in susceptibility of S. aureus 201 exposed to ABT492 or levofloxacin depended on the simulated AUC24/MIC. Although the maximal increase in MIC (MICfinal) related to its initial value (MICinitial) was seen at a higher AUC24/MIC ratio of ABT492 (120 h) than levofloxacin (50 h), similar AUC24/MICs (240 and 200 h, respectively) were protective against the selection of resistant S. aureus. These threshold values are readily achievable with 400 mg ABT492 (AUC24/MIC 870 h) but not with 500 mg levofloxacin (AUC24/MIC 70 h). Overall, these findings predict greater efficacy of clinically achievable AUC/MIC (or AUC24/MIC) of ABT492 both in terms of the anti-staphylococcal effect and prevention of the selection of resistant mutants.
Assessment of Ablative Therapies in Swine: Response of Respiratory Diaphragm to Varying Doses.
Singal, Ashish; Mattison, Lars M; Soule, Charles L; Ballard, John R; Rudie, Eric N; Cressman, Erik N K; Iaizzo, Paul A
2018-03-28
Ablation is a common procedure for treating patients with cancer, cardiac arrhythmia, and other conditions, yet it can cause collateral injury to the respiratory diaphragm. Collateral injury can alter the diaphragm's properties and/or lead to respiratory dysfunction. Thus, it is important to understand the diaphragm's physiologic and biomechanical properties in response to ablation therapies, in order to better understand ablative modalities, minimize complications, and maximize the safety and efficacy of ablative procedures. In this study, we analyzed physiologic and biomechanical properties of swine respiratory diaphragm muscle bundles when exposed to 5 ablative modalities. To assess physiologic properties, we performed in vitro tissue bath studies and measured changes in peak force and baseline force. To assess biomechanical properties, we performed uniaxial stress tests, measuring force-displacement responses, stress-strain characteristics, and avulsion forces. After treating the muscle bundles with all 5 ablative modalities, we observed dose-dependent sustained reductions in peak force and transient increases in baseline force-but no consistent dose-dependent biomechanical responses. These data provide novel insights into the effects of various ablative modalities on the respiratory diaphragm, insights that could enable improvements in ablative techniques and therapies.
Dose tracking and dose auditing in a comprehensive computed tomography dose-reduction program.
Duong, Phuong-Anh; Little, Brent P
2014-08-01
Implementation of a comprehensive computed tomography (CT) radiation dose-reduction program is a complex undertaking, requiring an assessment of baseline doses, an understanding of dose-saving techniques, and an ongoing appraisal of results. We describe the role of dose tracking in planning and executing a dose-reduction program and discuss the use of the American College of Radiology CT Dose Index Registry at our institution. We review the basics of dose-related CT scan parameters, the components of the dose report, and the dose-reduction techniques, showing how an understanding of each technique is important in effective auditing of "outlier" doses identified by dose tracking. Copyright © 2014 Elsevier Inc. All rights reserved.
Lievens, Yolande; Nulens, An; Gaber, Mousa Amr; Defraene, Gilles; De Wever, Walter; Stroobants, Sigrid; Van den Heuvel, Frank
2011-05-01
To evaluate the potential for dose escalation with intensity-modulated radiotherapy (IMRT) in positron emission tomography-based radiotherapy planning for locally advanced non-small-cell lung cancer (LA-NSCLC). For 35 LA-NSCLC patients, three-dimensional conformal radiotherapy and IMRT plans were made to a prescription dose (PD) of 66 Gy in 2-Gy fractions. Dose escalation was performed toward the maximal PD using secondary endpoint constraints for the lung, spinal cord, and heart, with de-escalation according to defined esophageal tolerance. Dose calculation was performed using the Eclipse pencil beam algorithm, and all plans were recalculated using a collapsed cone algorithm. The normal tissue complication probabilities were calculated for the lung (Grade 2 pneumonitis) and esophagus (acute toxicity, grade 2 or greater, and late toxicity). IMRT resulted in statistically significant decreases in the mean lung (p <.0001) and maximal spinal cord (p = .002 and 0005) doses, allowing an average increase in the PD of 8.6-14.2 Gy (p ≤.0001). This advantage was lost after de-escalation within the defined esophageal dose limits. The lung normal tissue complication probabilities were significantly lower for IMRT (p <.0001), even after dose escalation. For esophageal toxicity, IMRT significantly decreased the acute NTCP values at the low dose levels (p = .0009 and p <.0001). After maximal dose escalation, late esophageal tolerance became critical (p <.0001), especially when using IMRT, owing to the parallel increases in the esophageal dose and PD. In LA-NSCLC, IMRT offers the potential to significantly escalate the PD, dependent on the lung and spinal cord tolerance. However, parallel increases in the esophageal dose abolished the advantage, even when using collapsed cone algorithms. This is important to consider in the context of concomitant chemoradiotherapy schedules using IMRT. Copyright © 2011 Elsevier Inc. All rights reserved.
Influence of simulated microgravity on the maximal oxygen consumption of nontrained and trained rats
NASA Technical Reports Server (NTRS)
Woodman, Christopher R.; Monnin, Kimberly A.; Sebastian, Lisa A.; Tipton, Charles M.
1993-01-01
The effects of microgravity and endurance training (TR) on maximal O2 consumption was investigated in trained and nontrained (NT) rats subjected to head-down suspension (HDS) by comparing maximal O2 consumption, treadmill run time (RT), and mechanical efficiency (ME) of treadmill running in HDS rats, both NT and TR, and in respective cage controls. It was found that HDS for 28 days was associated with significant reduction in absolute maximal O2 consumption in both TR and NT rats. Relative maximal O2 consumption, however, was significantly reduced in TR but not NT rats. Reductions in RT and ME occurring in both TR and NT rats after 28 days of HDS were similar. The TR rats exhibited greater diuretic, natriuretic, and kaliuretic responses to HDS than the NT rats.
Shimonovich, Shachar; Gigi, Roy; Shapira, Amir; Sarig-Meth, Tal; Nadav, Danielle; Rozenek, Mattan; West, Debra; Halpern, Pinchas
2016-11-09
Ketamine has been well studied for its efficacy as an analgesic agent. However, intranasal (IN) administration of ketamine has only recently been studied in the emergency setting. The objective of this study was to elucidate the efficacy and adverse effects of a sub-dissociative dose of IN Ketamine compared to IV and IM morphine. A single-center, randomized, prospective, parallel clinical trial of efficacy and safety of IN ketamine compared to IV and IM morphine for analgesia in the emergency department (ED). A convenience sample of 90 patients aged 18-70 experiencing moderate-severe acute traumatic pain (≥80 mm on 100 mm Visual Analog Scale [VAS]) were randomized to receive either 1.0 mg/kg IN ketamine, 0.1 mg/kg IV MO or 0.15 mg/kg IM MO. Pain relief and adverse effects were recorded for 1 h post-administration. The primary outcome was efficacy of IN ketamine compared to IV and IM MO, measured by "time-to-onset" (defined as a ≥15 mm pain decrease on VAS), as well as time to and degree of maximal pain reduction. The 3 study groups showed a highly significant, similar maximal pain reduction of 56 ± 26 mm for IN Ketamine, and 59 ± 22 and 48 ± 30 for IV MO and IM MO, respectively. IN Ketamine provided clinically-comparable results to those of IV MO with regards to time to onset (14.3 ± 11.2 v. 8.9 ± 5.6 min, respectively) as well as in time to maximal pain reduction (40.4 ± 16.3) versus (33.4 ± 18), respectively. IN ketamine shows efficacy and safety comparable to IV and IM MO. Given the benefits of this mode of analgesia in emergencies, it should be further studied for potential clinical applications. Retrospectively registered on 27 June 2016. ClinicalTrials.gov ID: NCT02817477.
Dopaminergic influence on rat tongue function and limb movement initiation.
Ciucci, Michelle Renee; Connor, Nadine P
2009-04-01
Altering dopamine synaptic transmission can affect both cranial and limb sensorimotor function, but often to a different degree of severity. We hypothesized that haloperidol has dose-dependent but differential effects on lingual forces, lingual movement rates, and limb movement initiation. We measured average and maximal lingual force, tongue press rate and cataleptic descent time in nine Fischer 344/Brown Norway rats in varied doses of haloperidol. Decreases in lingual force and temporal parameters and increases in cataleptic descent time were related to haloperidol dose. However, they were related to a different degree as the relationships were strong between average force and tongue press rate, moderate between maximal force and tongue press rate, moderate between average force and cataleptic descent time, and weak between maximal force and cataleptic descent time. Elucidating the relationships between the cranial and limb sensorimotor systems in the context of altered dopamine synaptic transmission may assist in developing therapies for conditions such as Parkinson's disease.
Deininger, Michael W.; Kopecky, Kenneth J.; Radich, Jerald P.; Kamel-Reid, Suzanne; Stock, Wendy; Paietta, Elisabeth; Emanuel, Peter D.; Tallman, Martin; Wadleigh, Martha; Larson, Richard A.; Lipton, Jeffrey H.; Slovak, Marilyn L.; Appelbaum, Frederick R.; Druker, Brian J.
2014-01-01
The standard dose of imatinib for newly diagnosed patients with chronic phase chronic myeloid leukemia (CP-CML) is 400mg daily (IM400), but the optimal dose is unknown. This randomized phase II study compared the rates of molecular, haematologic and cytogenetic response to IM400 vs. imatinib 400mg twice daily (IM800) in 153 adult patients with CP-CML. Dose adjustments for toxicity were flexible to maximize retention on study. Molecular response (MR) at 12 months was deeper in the IM800 arm (4-log reduction of BCR-ABL1 mRNA: 25% vs. 10% of patients, P=0.038; 3-log reduction: 53% vs. 35%, P=0.049). During the first 12 months BCR-ABL1 levels in the IM800 arm were an average 2.9-fold lower than in the IM400 arm (P=0.010). Complete haematologic response was similar, but complete cytogenetic response was higher with IM800 (85% vs. 67%, P=0.040). Grade 3–4 toxicities were more common for IM800 (58% vs. 31%, P=0.0007), and were most commonly haematologic. Few patients have relapsed, progressed or died, but progression-free (P=0.048) and relapse-free (P=0.031) survival were superior for IM800. In newly diagnosed CP-CML patients, IM800 induced deeper molecular responses than IM400, with a trend for improved progression-free and overall survival, but was associated with more severe toxicity. PMID:24383843
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Z; Wang, I; Yao, R
Purpose: This study is to use plan parameters optimization (Dose rate, collimator angle, couch angle, initial starting phase) to improve the performance of conformal arc radiotherapy plans with motion tracking by increasing the plan performance score (PPS). Methods: Two types of 3D conformal arc plans were created based on QUASAR respiratory motion phantom with spherical and cylindrical targets. Sinusoidal model was applied to the MLC leaves to generate motion tracking plans. A MATLAB program was developed to calculate PPS of each plan (ranges from 0–1) and optimize plan parameters. We first selected the dose rate for motion tracking plans andmore » then used simulated annealing algorithm to search for the combination of the other parameters that resulted in the plan of the maximal PPS. The optimized motion tracking plan was delivered by Varian Truebeam Linac. In-room cameras and stopwatch were used for starting phase selection and synchronization between phantom motion and plan delivery. Gaf-EBT2 dosimetry films were used to measure the dose delivered to the target in QUASAR phantom. Dose profiles and Truebeam trajectory log files were used for plan delivery performance evaluation. Results: For spherical target, the maximal PPS (PPSsph) of the optimized plan was 0.79: (Dose rate: 500MU/min, Collimator: 90°, Couch: +10°, starting phase: 0.83π). For cylindrical target, the maximal PPScyl was 0.75 (Dose rate: 300MU/min, Collimator: 87°, starting phase: 0.97π) with couch at 0°. Differences of dose profiles between motion tracking plans (with the maximal and the minimal PPS) and 3D conformal plans were as follows: PPSsph=0.79: %ΔFWHM: 8.9%, %Dmax: 3.1%; PPSsph=0.52: %ΔFWHM: 10.4%, %Dmax: 6.1%. PPScyl=0.75: %ΔFWHM: 4.7%, %Dmax: 3.6%; PPScyl=0.42: %ΔFWHM: 12.5%, %Dmax: 9.6%. Conclusion: By achieving high plan performance score through parameters optimization, we can improve target dose conformity of motion tracking plan by decreasing total MLC leaf travel distance and leaf speed.« less
Renin-angiotensin system blockers regulate the metabolism of isolated fat cells in vitro
Caminhotto, R de O.; Sertié, R.A.L.; Andreotti, S.; Campaãa, A.B.; Lima, F.B.
2016-01-01
Due to the presence of the renin-angiotensin system (RAS) in tissues and its specific influence on white adipose tissue, fat cells are possible targets of pharmacological RAS blockers commonly used as anti-hypertensive drugs. In the present study, we investigated the effects of different RAS blockers on fat cell metabolism, more specifically on lipolysis, lipogenesis and oxidation of energy substrates. Isolated primary adipocytes were incubated with different RAS blockers (aliskiren, captopril and losartan) in vitro for 24 h and lipolysis, lipogenesis and glucose oxidation capacities were determined in dose-response assays to a β-adrenergic agonist and to insulin. Although no change was found in lipolytic capacity, the RAS blockers modulated lipogenesis and glucose oxidation in a different way. While captopril decreased insulin-stimulated lipogenesis (−19% of maximal response and −60% of insulin responsiveness) due to reduced glucose derived glycerol synthesis (−19% of maximal response and 64% of insulin responsiveness), aliskiren increased insulin-stimulated glucose oxidation (+49% of maximal response and +292% of insulin responsiveness) in fat cells. Our experiments demonstrate that RAS blockers can differentially induce metabolic alterations in adipocyte metabolism, characterized by a reduction in lipogenic responsiveness or an increase in glucose oxidation. The impact of RAS blockers on adipocyte metabolism may have beneficial implications on metabolic disorders during their therapeutic use in hypertensive patients. PMID:27487419
Horton, Dane M; Saint, David A; Owens, Julie A; Gatford, Kathryn L; Kind, Karen L
2017-07-01
The guinea pig is an alternate small animal model for the study of metabolism, including insulin sensitivity. However, only one study to date has reported the use of the hyperinsulinemic euglycemic clamp in anesthetized animals in this species, and the dose response has not been reported. We therefore characterized the dose-response curve for whole body glucose uptake using recombinant human insulin in the adult guinea pig. Interspecies comparisons with published data showed species differences in maximal whole body responses (guinea pig ≈ human < rat < mouse) and the insulin concentrations at which half-maximal insulin responses occurred (guinea pig > human ≈ rat > mouse). In subsequent studies, we used concomitant d-[3- 3 H]glucose infusion to characterize insulin sensitivities of whole body glucose uptake, utilization, production, storage, and glycolysis in young adult guinea pigs at human insulin doses that produced approximately half-maximal (7.5 mU·min -1 ·kg -1 ) and near-maximal whole body responses (30 mU·min -1 ·kg -1 ). Although human insulin infusion increased rates of glucose utilization (up to 68%) and storage and, at high concentrations, increased rates of glycolysis in females, glucose production was only partially suppressed (~23%), even at high insulin doses. Fasting glucose, metabolic clearance of insulin, and rates of glucose utilization, storage, and production during insulin stimulation were higher in female than in male guinea pigs ( P < 0.05), but insulin sensitivity of these and whole body glucose uptake did not differ between sexes. This study establishes a method for measuring partitioned glucose metabolism in chronically catheterized conscious guinea pigs, allowing studies of regulation of insulin sensitivity in this species. Copyright © 2017 the American Physiological Society.
Qiao, Wen-Bo; Zhao, Yan-Hui; Zhao, Yan-Bin; Wang, Rui-Zhi
2005-05-07
To analyze the clinical and dosimetric predictive factors for radiation-induced esophageal injury in patients with non-small-cell lung cancer (NSCLC) during three-dimensional conformal radiotherapy (3D-CRT). We retrospectively analyzed 208 consecutive patients (146 men and 62 women) with NSCLC treated with 3D-CRT. The median age of the patients was 64 years (range 35-87 years). The clinical and treatment parameters including gender, age, performance status, sequential chemotherapy, concurrent chemotherapy, presence of carinal or subcarinal lymph nodes, pretreatment weight loss, mean dose to the entire esophagus, maximal point dose to the esophagus, and percentage of volume of esophagus receiving >55 Gy were studied. Clinical and dosimetric factors for radiation-induced acute and late grade 3-5 esophageal injury were analyzed according to Radiation Therapy Oncology Group (RTOG) criteria. Twenty-five (12%) of the two hundred and eight patients developed acute or late grade 3-5 esophageal injury. Among them, nine patients had both acute and late grade 3-5 esophageal injury, two died of late esophageal perforation. Concurrent chemotherapy and maximal point dose to the esophagus > or =60 Gy were significantly associated with the risk of grade 3-5 esophageal injury. Fifty-four (26%) of the two hundred and eight patients received concurrent chemotherapy. Among them, 25 (46%) developed grade 3-5 esophageal injury (P = 0.0001<0.01). However, no grade 3-5 esophageal injury occurred in patients who received a maximal point dose to the esophagus <60 Gy (P = 0.0001<0.01). Concurrent chemotherapy and the maximal esophageal point dose > or =60 Gy are significantly associated with the risk of grade 3-5 esophageal injury in patients with NSCLC treated with 3D-CRT.
Exercise Responses after Inactivity
NASA Technical Reports Server (NTRS)
Convertino, Victor A.
1986-01-01
The exercise response after bed rest inactivity is a reduction in the physical work capacity and is manifested by significant decreases in oxygen uptake. The magnitude of decrease in maximal oxygen intake V(dot)O2max is related to the duration of confinement and the pre-bed-rest level of aerobic fitness; these relationships are relatively independent of age and gender. The reduced exercise performance and V(dot)O2max following bed rest are associated with various physiological adaptations including reductions in blood volume, submaximal and maximal stroke volume, maximal cardiac output, sceletal muscle tone and strength, and aerobic enzyme capacities, as well as increases in venous compliance and submaximal and maximal heart rate. This reduction in physiological capacity can be partially restored by specific countermeasures that provide regular muscular activity or orhtostatic stress or both during the bed rest exposure. The understanding of these physiological and physical responses to exercise following bed rest inactivity has important implications for the solution to safety and health problems that arise in clinical medicine, aerospace medicine, sedentary living, and aging.
Multiple-, But Not Single-, Dose of Parecoxib Reduces Shoulder Pain after Gynecologic Laparoscopy
Zhang, Hufei; Shu, Haihua; Yang, Lu; Cao, Minghui; Zhang, Jingjun; Liu, Kexuan; Xiao, Liangcan; Zhang, Xuyu
2012-01-01
Background: The aim of this study was to investigate effect of single- and multiple-dose of parecoxib on shoulder pain after gynecologic laparoscopy. Methods: 126 patients requiring elective gynecologic laparoscopy were randomly allocated to three groups. Group M (multiple-dose): receiving parecoxib 40mg at 30min before the end of surgery, at 8 and 20hr after surgery, respectively; Group S (single-dose): receiving parecoxib 40mg at 30min before the end of surgery and normal saline at the corresponding time points; Group C (control): receiving normal saline at the same three time points. The shoulder pain was evaluated, both at rest and with motion, at postoperative 6, 24 and 48hr. The impact of shoulder pain on patients' recovery (activity, mood, walking and sleep) was also evaluated. Meanwhile, rescue analgesics and complications were recorded. Results: The overall incidence of shoulder pain in group M (37.5%) was lower than that in group C (61.9%) (difference=-24.4%; 95% CI: 3.4~45.4%; P=0.023). Whereas, single-dose regimen (61.0%) showed no significant reduction (difference with control=-0.9%; 95% CI: -21.9~20.0%; P=0.931). Moreover, multiple-dose regimen reduced the maximal intensity of shoulder pain and the impact for activity and mood in comparison to the control. Multiple-dose of parecoxib decreased the consumption of rescue analgesics. The complications were similar among all groups and no severe complications were observed. Conclusions: Multiple-, but not single-, dose of parecoxib may attenuate the incidence and intensity of shoulder pain and thereby improve patients' quality of recovery following gynecologic laparoscopy. PMID:23136538
Huynh Le Maux, Amélie; Pignol, Bernadette; Behr-Roussel, Delphine; Blachon, Jean-Luc; Chabrier, Pierre-Etienne; Compagnie, Sandrine; Picaut, Philippe; Bernabé, Jacques; Giuliano, François; Denys, Pierre
2015-01-01
Intradetrusor injections of Botulinum toxin A—currently onabotulinumtoxinA—is registered as a second-line treatment to treat neurogenic detrusor overactivity (NDO). The common clinical practice is 30 × 1 mL injections in the detrusor; however, protocols remain variable and standardization is warranted. The effect of reducing the number of injection sites of Dysport® abobotulinumtoxinA (aboBoNTA) was assessed in the spinal cord-injured rat (SCI). Nineteen days post-spinalization, female rats received intradetrusor injections of saline or aboBoNTA 22.5 U distributed among four or eight sites. Two days after injection, continuous cystometry was performed in conscious rats. Efficacy of aboBoNTA 22.5 U was assessed versus aggregated saline groups on clinically-relevant parameters: maximal pressure, bladder capacity, compliance, voiding efficiency, as well as amplitude, frequency, and volume threshold for nonvoiding contractions (NVC). AboBoNTA 22.5 U significantly decreased maximal pressure, without affecting voiding efficiency. Injected in four sites, aboBoNTA significantly increased bladder capacity and compliance while only the latter when in eight sites. AboBoNTA significantly reduced NVC frequency and amplitude. This preclinical investigation showed similar inhibiting effects of aboBoNTA despite the number of sites reduction. Further studies are warranted to optimize dosing schemes to improve the risk-benefit ratio of BoNTA-based treatment modalities for NDO and further idiopathic overactive bladder. PMID:26694464
Development of a biologically based dose response (BBDR) model for arsenic induced cancer
We are developing a biologically based dose response (BBDR) model for arsenic carcinogenicity in order to reduce uncertainty in estimates of low dose risk by maximizing the use of relevant data on the mode of action. Expert consultation and literature review are being conducted t...
Olmesartan/amlodipine: a review of its use in the management of hypertension
Kreutz, R
2011-01-01
Combination therapy is an effective strategy to increase antihypertensive efficacy in those patients with poor blood pressure (BP) control. In order to achieve BP targets, at least 75% of patients may require combination therapy, and European guidelines advocate this approach, particularly in those patients with a high cardiovascular risk. Evidence from large, randomized controlled trials, and the European hypertension treatment guidelines is supportive of the use of an angiotensin receptor blocker (ARB) with a calcium channel blocker (CCB). Fixed-dose combination formulations of olmesartan medoxomil, an ARB, and the CCB amlodipine are approved in several European countries for patients with essential hypertension. The olmesartan/amlodipine combination has demonstrated greater efficacy than its component monotherapies in reducing BP in patients with mild-to-severe hypertension. Significantly greater reductions in seated diastolic BP were observed between baseline and after eight weeks of treatment with olmesartan/amlodipine, compared with equivalent doses of olmesartan or amolodipine monotherapy (P < 0.001), in the factorial Combination of Olmesartan Medoxomil and Amlodipine Besylate in Controlling High Blood Pressure (COACH) trial. About 85% of the maximal BP reductions after the 8-week treatment period were already observed after two weeks. Uptitration as necessary, with or without hydrochlorothiazide, allowed the majority of patients to achieve BP control in a 44-week open-label extension treatment period to the COACH trial. The use of olmesartan/amlodipine allowed up to 54% of patients, with previously inadequate responses to amlodipine or olmesartan monotherapy, to achieve their BP goals. Data from post-registration studies using tight BP control and forced titration regimens have further demonstrated the high efficacy of olmesartan/amlodipine in achieving BP goal rates. Moreover, consistent reductions in BP were observed over the 24-hour dosing interval using ambulatory measurements. Olmesartan/amlodipine was generally well tolerated over the short- and long-term, with a lower frequency of peripheral edema with olmesartan/amlodipine 40/10 mg than with amlodipine 10 mg monotherapy. PMID:21490944
Pogge, Elizabeth K; Davis, Lindsay E
2018-04-01
The objective of this research was to describe the use of pharmacist-managed sacubitril/valsartan therapy in a multi-center, outpatient cardiac group. Sacubitril/valsartan, an angiotensin receptor-neprilysin inhibitor (ARNi), is a novel agent for the treatment of heart failure. An ARNi is recommended by national guidelines to be used in place of angiotensin-converting enzyme inhibitor (ACEi) or angiotensin receptor blocker (ARB) therapy for patients who remain symptomatic. A retrospective chart review was performed to identify patients initiated and fully titrated on sacubitril/valsartan therapy from July 7, 2015 to March 7, 2017. Fifty-two of the 72 symptomatic heart failure with reduced ejection fraction (HFrEF) patients prescribed sacubitril/valsartan during the 21-month period were included in this analysis. The average ejection fraction was 26%. The average age was 69 years. At baseline, 26.9% of patients were not on ACEi/ARB therapy and 13.5% were on target-dose therapy. After completing the uptitration process, the maximally tolerated dose of sacubitril/valsartan was 5.8% low-dose, 7.7% mid-dose, and 86.5% target-dose. Loop and thiazide diuretic use decreased significantly. There was a significant mean reduction in systolic blood pressure of 6 mmHg with no significant changes in serum creatinine, blood urea nitrogen, or potassium levels. With close monitoring and follow-up, ARNi therapy was a safe alternative to ACEi/ARB therapy for chronic symptomatic HFrEF when initiated within a pharmacist clinic.
Pharmacokinetic profiles of repaglinide in elderly subjects with type 2 diabetes.
Hatorp, V; Huang, W C; Strange, P
1999-04-01
Pharmacokinetic profiles of single- and multiple-dose regimens of repaglinide were evaluated in 12 elderly subjects with type 2 diabetes. On day 1, following a 10-hour fast, subjects received a single 2-mg dose of repaglinide. Starting on day 2 and continuing for 7 days, each subject received a 2-mg dose of repaglinide 15 minutes before each of the three main meals. On day 9, subjects received a single 2-mg dose of repaglinide. Pharmacokinetic profiles, including area under the curve (AUC), log(AUC), maximal concentration (Cmax), log(Cmax), time to maximal concentration (Tmax), and half-life (T(1/2)), were determined at completion of the single- and multiple-dose regimens (days 1 and 9, respectively). Trough repaglinide values were collected on days 2 through 7. The mean log(AUC) values after multiple dosing were significantly higher than the values obtained after a single dose. The mean values for log(Cmax), and Tmax were comparable after each dosing regimen. The T(1/2) of repaglinide after multiple dosing was 1.7 hours. The trough values for repaglinide were low. No hypoglycemic events were reported. The pharmacokinetic profiles of repaglinide after single- and multiple-dose regimens were similar, and repaglinide was well tolerated by elderly subjects with type 2 diabetes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pokhrel, D; Badkul, R; Jiang, H
Purpose: To compare dose distributions calculated using the iPlan XVMC algorithm and heterogeneities corrected/uncorrected Pencil Beam (PB-hete/PB-homo) algorithms for SBRT treatments of lung tumors. Methods: Ten patients with centrally located solitary lung tumors were treated using MC-based SBRT to 60Gy in 5 fractions for PTVV100%=95%. ITV was delineated on MIP-images based on 4D-CT scans. PTVs(ITV+5mm margins) ranged from 10.1–106.5cc(mean=48.6cc). MC-SBRT plans were generated with a combination of non-coplanar conformal arcs/beams using iPlan-XVMC-algorithm (BrainLABiPlan ver.4.1.2) for Novalis-TX consisting of HD-MLCs and 6MV-SRS(1000MU/min) mode, following RTOG 0813 dosimetric criteria. For comparison, PB-hete/PB-homo algorithms were used to re-calculate dose distributions using same beammore » configurations, MLCs/monitor units. Plans were evaluated with isocenter/maximal/mean doses to PTV. Normal lung doses were evaluated with V5/V10/V20 and mean-lung-dose(MLD), excluding PTV. Other OAR doses such as maximal spinal cord/2cc-esophagus/max bronchial tree (BT/maximal heart doses were tabulated. Results: Maximal/mean/isocenter doses to PTV calculated by PB-hete were uniformly larger than MC plans by a factors of 1.09/1.13/1.07, on average, whereas they were consistently lower by PB-homo by a factors of 0.9/0.84/0.9, respectively. The volume covered by 5Gy/10Gy/20Gy isodose-lines of the lung were comparable (average within±3%) when calculated by PB-hete compared to XVMC, but, consistently lower by PB-homo by a factors of 0.90/0.88/0.85, respectively. MLD was higher with PB-hete by 1.05, but, lower by PB-homo by 0.9, on average, compared to XVMC. XVMC max-cord/max-BT/max-heart and 2cc of esophagus doses were comparable to PB-hete; however, PB-homo underestimates by a factors of 0.82/0.89/0.88/0.86, on average, respectively. Conclusion: PB-hete significantly overestimates dose to PTV relative to XVMC -hence underdosing the target. MC is more complex and accurate with tissue-heterogeneities.The magnitude of variation significantly varies with ‘small-island-tumor’ surrounded by low-density lung tissues -PB algorithms lacks later electron scattering. Dose calculation with XVMC for lung SBRT is routinely performed in our clinic, its performance for head'neck/sinus cases will also be investigated.« less
Oxytocin Reduces Ethanol Self-Administration in Mice.
King, Courtney E; Griffin, William C; Luderman, Lauryn N; Kates, Malcolm M; McGinty, Jacqueline F; Becker, Howard C
2017-05-01
Excessive ethanol (EtOH) consumption remains an important health concern and effective treatments are lacking. The central oxytocin system has emerged as a potentially important therapeutic target for alcohol and drug addiction. These studies tested the hypothesis that oxytocin reduces EtOH consumption. Male C57BL/6J mice were given access to EtOH (20% v/v) using a model of binge-like drinking ("drinking in the dark") that also included the use of lickometer circuits to evaluate the temporal pattern of intake as well as 2-bottle choice drinking in the home cage. In addition, EtOH (12% v/v) and sucrose (5% w/v) self-administration on fixed- and progressive-ratio schedules were also evaluated. A wide range of systemically administered oxytocin doses were tested (0 to 10 mg/kg) in these models. Oxytocin (0, 0.3, 1, 3, or 10 mg/kg) dose dependently reduced EtOH consumption (maximal 45% reduction) in the binge drinking model, with lower effective doses having minimal effects on general locomotor activity. Oxytocin's effect was blocked by pretreatment with an oxytocin receptor antagonist, and the pattern of contacts (licks) at the EtOH bottle suggested a reduction in motivation to drink EtOH. Oxytocin decreased 2-bottle choice drinking without altering general fluid intake. Oxytocin also reduced operant responding for EtOH and sucrose in a dose-related manner. However, oxytocin decreased responding and motivation (breakpoint values) for EtOH at doses that did not alter responding for sucrose. These results indicate that oxytocin reduces EtOH consumption in different models of self-administration. The effects are not likely due to a general sedative effect of the neuropeptide. Further, oxytocin reduces motivation for EtOH at doses that do not alter responding for a natural reward (sucrose). While some evidence supports a role for oxytocin receptors in mediating these effects, additional studies are needed to further elucidate underlying mechanisms. Nevertheless, these results support the therapeutic potential of oxytocin as a treatment for alcohol use disorder. Copyright © 2017 by the Research Society on Alcoholism.
Yamano, Tetsuo; Shimizu, Mitsuru; Noda, Tsutomu
2005-07-01
We compared the results of the multiple-dose guinea pig maximization test (GPMT) and the non-radioactive murine local lymph-node assay (LLNA) for various biocides. Thirteen out of 17 positive biocides in the GPMT gave positive results in the LLNA. In the GPMT, the minimum first induction doses ranged over four orders (0.00005-0.5%), while elicitation-threshold doses, which were evaluated using an optimally sensitized group of animals in the multiple-dose studies, ranged over five orders (0.00006-2.8%). In the LLNA, minimum induction doses ranged over more than three orders (0.01-30%). With respect to 13 biocides that were positive in both the GPMT and the LLNA, results were quantitatively compared. When compared after conversion to corresponding area doses (microg/cm), the minimum doses required to elicit skin reaction in guinea pigs were always lower than that for induction in mice with all biocides. Correlation between minimum induction doses from the GPMT and the LLNA seemed poor (r=0.57), while that between minimum induction doses in the LLNA and elicitation-threshold doses in the GPMT was relatively good (r=0.73). The results suggest the possibility to estimate human elicitation-threshold doses, which are definitely lacking in the process of risk assessment for skin-sensitizers, from the data of the LLNA.
Schulz, Craig A; Mehta, Minesh P; Badie, Benham; McGinn, Cornelius J; Robins, H Ian; Hayes, Lori; Chappell, Rick; Volkman, Jen; Binger, Kim; Arzoomanian, Rhoda; Simon, Kris; Alberti, Dona; Feierabend, Christine; Tutsch, Kendra D; Kunugi, Keith A; Wilding, George; Kinsella, Timothy J
2004-07-15
To investigate the maximal tolerated dose of a continuous 28-day iododeoxyuridine (IUdr) infusion combined with hyperfractionated accelerated radiotherapy (HART); to analyze the percentage of IUdr-thymidine replacement in peripheral granulocytes as a surrogate marker for IUdr incorporation into tumor cells; to measure the steady-state serum IUdr levels; and to assess the feasibility of continuous IUdr infusion and HART in the management of malignant glioma. Patients were required to have biopsy-proven malignant glioma. Patients received 100 (n = 4), 200 (n = 3), 300 (n = 3), 400 (n = 6), 500 (n = 4), 625 (n = 5), or 781 (n = 6) mg/m(2)/d of IUdr by continuous infusion for 28 days. HART was started 7 days after IUdr initiation. The total dose was 70 Gy (1.2 Gy b.i.d. for 25 days with a 10-Gy boost [2.0 Gy for 5 Saturdays]). Weekly assays were performed to determine the percentage of IUdr-DNA replacement in granulocytes and serum IUdr levels using standard high performance liquid chromatography methods. Standard Phase I toxicity methods were used. Between June 1994 and August 1999, 31 patients were enrolled. No patient had Grade 3 or worse HART toxicity. Grade 3 or greater IUdr toxicity predominantly included neutropenia (n = 3), thrombocytopenia (n = 3), and elevated liver function studies (n = 3). The maximal tolerated dose was 625 mg/m(2)/d. Thymidine replacement in the peripheral granulocytes peaked at 3 weeks and increased with the dose (maximal thymidine replacement 4.9%). The steady-state plasma IUdr level increased with the dose (maximum, 1.5 microM). In our study, continuous long-term IUdr i.v. infusion had a maximal tolerated dose of 625 mg/m(2)/d. Granulocyte incorporation data verified the concept that prolonged IUdr infusion results in IUdr-DNA replacement that corresponds to a high degree of cell labeling. IUdr steady-state plasma levels increased with increasing dose and attained levels needed for clinical radiosensitization. Continuous IUdr infusion and HART were both feasible and well tolerated.
Dose reduction potential of iterative reconstruction algorithms in neck CTA-a simulation study.
Ellmann, Stephan; Kammerer, Ferdinand; Allmendinger, Thomas; Brand, Michael; Janka, Rolf; Hammon, Matthias; Lell, Michael M; Uder, Michael; Kramer, Manuel
2016-10-01
This study aimed to determine the degree of radiation dose reduction in neck CT angiography (CTA) achievable with Sinogram-affirmed iterative reconstruction (SAFIRE) algorithms. 10 consecutive patients scheduled for neck CTA were included in this study. CTA images of the external carotid arteries either were reconstructed with filtered back projection (FBP) at full radiation dose level or underwent simulated dose reduction by proprietary reconstruction software. The dose-reduced images were reconstructed using either SAFIRE 3 or SAFIRE 5 and compared with full-dose FBP images in terms of vessel definition. 5 observers performed a total of 3000 pairwise comparisons. SAFIRE allowed substantial radiation dose reductions in neck CTA while maintaining vessel definition. The possible levels of radiation dose reduction ranged from approximately 34 to approximately 90% and depended on the SAFIRE algorithm strength and the size of the vessel of interest. In general, larger vessels permitted higher degrees of radiation dose reduction, especially with higher SAFIRE strength levels. With small vessels, the superiority of SAFIRE 5 over SAFIRE 3 was lost. Neck CTA can be performed with substantially less radiation dose when SAFIRE is applied. The exact degree of radiation dose reduction should be adapted to the clinical question, in particular to the smallest vessel needing excellent definition.
What's wrong with hazard-ranking systems? An expository note.
Cox, Louis Anthony Tony
2009-07-01
Two commonly recommended principles for allocating risk management resources to remediate uncertain hazards are: (1) select a subset to maximize risk-reduction benefits (e.g., maximize the von Neumann-Morgenstern expected utility of the selected risk-reducing activities), and (2) assign priorities to risk-reducing opportunities and then select activities from the top of the priority list down until no more can be afforded. When different activities create uncertain but correlated risk reductions, as is often the case in practice, then these principles are inconsistent: priority scoring and ranking fails to maximize risk-reduction benefits. Real-world risk priority scoring systems used in homeland security and terrorism risk assessment, environmental risk management, information system vulnerability rating, business risk matrices, and many other important applications do not exploit correlations among risk-reducing opportunities or optimally diversify risk-reducing investments. As a result, they generally make suboptimal risk management recommendations. Applying portfolio optimization methods instead of risk prioritization ranking, rating, or scoring methods can achieve greater risk-reduction value for resources spent.
Distribution of sulfamonomethoxine and trimethoprim in egg yolk and white.
Bilandžić, Nina; Božić, Đurđica; Kolanović, Božica Solomun; Varenina, Ivana; Cvetnić, Luka; Cvetnić, Željko
2015-07-01
The distribution of sulfamonomethoxine (SMM) and trimethoprim (TMP) in egg yolk and white was measured during and after administration of a SMM/TMP combination in laying hens in doses of 8 g l(-)(1) and 12 g l(-)(1) in drinking water for 7 days. The SMM concentration reached maximal levels on day 2 of the post-treatment period for both doses (μg kg(-)(1)): 5920 and 9453 in yolk; 4831 and 6050 in white, in doses 1 and 2, respectively. Significant differences in the SMM and TMP concentrations between yolk and white in post treatment period were found. SMM dropped below the LOD (1.9 μg kg(-1)) in yolk after day 16 and 19 for doses 1 and 2. TMP reached maximal levels on day 3 after drug administration for doses 1 and 2 (μg kg(-)(1)): 6521 and 7329 in yolk, 1370 and 1539 in white. TMP residues were measured above LOD (0.3 μg kg(-)(1)) in yolk for both doses on day 37 post-treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.
Technique for comprehensive head and neck irradiation using 3-dimensional conformal proton therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDonald, Mark W., E-mail: markmcdonaldmd@gmail.com; Indiana University Health Proton Therapy Center, Bloomington, IN; Walter, Alexander S.
2015-01-01
Owing to the technical and logistical complexities of matching photon and proton treatment modalities, we developed and implemented a technique of comprehensive head and neck radiation using 3-dimensional (3D) conformal proton therapy. A monoisocentric technique was used with a 30-cm snout. Cervical lymphatics were treated with 3 fields: a posterior-anterior field with a midline block and a right and a left posterior oblique field. The matchline of the 3 cervical nodal fields with the primary tumor site fields was staggered by 0.5 cm. Comparative intensity-modulated photon plans were later developed for 12 previously treated patients to provide equivalent target coverage,more » while matching or improving on the proton plans' sparing of organs at risk (OARs). Dosimetry to OARs was evaluated and compared by treatment modality. Comprehensive head and neck irradiation using proton therapy yielded treatment plans with significant dose avoidance of the oral cavity and midline neck structures. When compared with the generated intensity-modulated radiation therapy (IMRT) plans, the proton treatment plans yielded statistically significant reductions in the mean and integral radiation dose to the oral cavity, larynx, esophagus, and the maximally spared parotid gland. There was no significant difference in mean dose to the lesser-spared parotid gland by treatment modality or in mean or integral dose to the spared submandibular glands. A technique for cervical nodal irradiation using 3D conformal proton therapy with uniform scanning was developed and clinically implemented. Use of proton therapy for cervical nodal irradiation resulted in large volume of dose avoidance to the oral cavity and low dose exposure to midline structures of the larynx and the esophagus, with lower mean and integral dose to assessed OARs when compared with competing IMRT plans.« less
Cheung, D; Timmers, M C; Zwinderman, A H; den Hartigh, J; Dijkman, J H; Sterk, P J
1993-12-01
In a previous study we have shown that inhibition of the endogenous neuropeptide-degrading enzyme, neutral endopeptidase (NEP), potentiates airway narrowing to neurokinin A (NKA) in normal humans in vivo. In the present study, we tested the hypothesis that hyperresponsiveness to NKA in asthma is caused by a reduction in endogenous NEP activity. To that end, we used the NEP inhibitor, thiorphan, or placebo as inhaled pretreatment to NKA challenge in eight atopic asthmatic men, who were controlled by on-demand usage of beta 2-agonists alone. The dose of thiorphan pretreatment was obtained from pilot experiments in which 0.5 ml of a 2.5-mg/ml concentration appeared to be the maximally effective nebulized dose. Dose-response curves to inhaled NKA (1 to 125 micrograms/ml, 0.5 ml/dose) were recorded on 2 randomized days 1 wk apart, in a cross-over study. To detect any effects of thiorphan on bronchoconstriction per se, we also investigated the effect of thiorphan or placebo on the dose-response curve to inhaled methacholine in a separate set of experiments. The response was measured by FEV1 and by partial expiratory flow-volume curves (V40p). The position of the dose-response curves was expressed as the concentration causing a 20% fall in FEV1 (PC20FEV1) or a 40% fall in V40p (PC40V40p). Baseline FEV1 and V40p were not affected by either pretreatment (p > 0.06). PC20FEV1 and PC40V40p to NKA were significantly lower after thiorphan pretreatment as compared with placebo (mean difference +/- SEM: 2.3 +/- 0.6 and 1.6 +/- 0.5 doubling dose, respectively; p < 0.015).(ABSTRACT TRUNCATED AT 250 WORDS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baardwijk, Angela van; Bosmans, Geert; Boersma, Liesbeth
2008-08-01
Purpose: Local recurrence is a major problem after (chemo-)radiation for non-small-cell lung cancer. We hypothesized that for each individual patient, the highest therapeutic ratio could be achieved by increasing total tumor dose (TTD) to the limits of normal tissues, delivered within 5 weeks. We report first results of a prospective feasibility trial. Methods and Materials: Twenty-eight patients with medically inoperable or locally advanced non-small-cell lung cancer, World Health Organization performance score of 0-1, and reasonable lung function (forced expiratory volume in 1 second > 50%) were analyzed. All patients underwent irradiation using an individualized prescribed TTD based on normal tissuemore » dose constraints (mean lung dose, 19 Gy; maximal spinal cord dose, 54 Gy) up to a maximal TTD of 79.2 Gy in 1.8-Gy fractions twice daily. No concurrent chemoradiation was administered. Toxicity was scored using the Common Terminology Criteria for Adverse Events criteria. An {sup 18}F-fluoro-2-deoxy-glucose-positron emission tomography-computed tomography scan was performed to evaluate (metabolic) response 3 months after treatment. Results: Mean delivered dose was 63.0 {+-} 9.8 Gy. The TTD was most often limited by the mean lung dose (32.1%) or spinal cord (28.6%). Acute toxicity generally was mild; only 1 patient experienced Grade 3 cough and 1 patient experienced Grade 3 dysphagia. One patient (3.6%) died of pneumonitis. For late toxicity, 2 patients (7.7%) had Grade 3 cough or dyspnea; none had severe dysphagia. Complete metabolic response was obtained in 44% (11 of 26 patients). With a median follow-up of 13 months, median overall survival was 19.6 months, with a 1-year survival rate of 57.1%. Conclusions: Individualized maximal tolerable dose irradiation based on normal tissue dose constraints is feasible, and initial results are promising.« less
The effect of lifelong exercise dose on cardiovascular function during exercise
Carrick-Ranson, Graeme; Hastings, Jeffrey L.; Bhella, Paul S.; Fujimoto, Naoki; Shibata, Shigeki; Palmer, M. Dean; Boyd, Kara; Livingston, Sheryl; Dijk, Erika
2014-01-01
An increased “dose” of endurance exercise training is associated with a greater maximal oxygen uptake (V̇o2max), a larger left ventricular (LV) mass, and improved heart rate and blood pressure control. However, the effect of lifelong exercise dose on metabolic and hemodynamic response during exercise has not been previously examined. We performed a cross-sectional study on 101 (69 men) seniors (60 yr and older) focusing on lifelong exercise frequency as an index of exercise dose. These included 27 who had performed ≤2 exercise sessions/wk (sedentary), 25 who performed 2–3 sessions/wk (casual), 24 who performed 4–5 sessions/wk (committed) and 25 who performed ≥6 sessions/wk plus regular competitions (Masters athletes) over at least the last 25 yr. Oxygen uptake and hemodynamics [cardiac output, stroke volume (SV)] were collected at rest, two levels of steady-state submaximal exercise, and maximal exercise. Doppler ultrasound measures of LV diastolic filling were assessed at rest and during LV loading (saline infusion) to simulate increased LV filling. Body composition, total blood volume, and heart rate recovery after maximal exercise were also examined. V̇o2max increased in a dose-dependent manner (P < 0.05). At maximal exercise, cardiac output and SV were largest in committed exercisers and Masters athletes (P < 0.05), while arteriovenous oxygen difference was greater in all trained groups (P < 0.05). At maximal exercise, effective arterial elastance, an index of ventricular-arterial coupling, was lower in committed exercisers and Masters athletes (P < 0.05). Doppler measures of LV filling were not enhanced at any condition, irrespective of lifelong exercise frequency. These data suggest that performing four or more weekly endurance exercise sessions over a lifetime results in significant gains in V̇o2max, SV, and heart rate regulation during exercise; however, improved SV regulation during exercise is not coupled with favorable effects on LV filling, even when the heart is fully loaded. PMID:24458750
Sizes of particles formed during municipal wastewater treatment.
Lech, Smoczynski; Marta, Kosobucka; Michal, Smoczynski; Harsha, Ratnaweera; Krystyna, Pieczulis-Smoczynska
2017-02-01
Volumetric diameters Dv and specific surface area SpS of sludge particles formed during chemical coagulation and electrocoagulation of sewage were determined. The obtained aggregate-flocs differed substantially in both Dv and SpS values. The differences in Dv and SpS values of the analyzed particles were interpreted based on theoretical models for expanding aggregates. The most uniform particles were formed under exposure to: (a) optimal and maximal doses of PIX, (b) optimal doses of PAX, (c) maximal doses of the Al electro-coagulant. The lowest PIX dose produced the least uniform particles. Sludge aggregates-particles produced under exposure to minimal doses of PIX and the Al electro-coagulant were characterized by the lowest SpS values. Sludge particles coagulated by PAX and the particles formed at higher doses of PIX and the Al electro-coagulant had higher SpS values. The particles formed at all doses of the applied coagulants and electro-coagulants were generally classified into two size ranges: the main range and the secondary range. Most particles belonged to the main size range. An increase in the percentage of colloidal hydroxide particles in sewage sludge increased SpS.
Maximizing the success of bile duct cannulation studies in rats: recommendations for best practice.
Burden, Natalie; Kendrick, John; Knight, Lindsay; McGregor, Victoria; Murphy, Helen; Punler, Malcolm; van Wijk, Hans
2017-10-01
Bile duct cannulation (BDC) studies are usually carried out in the rat to support the absorption, distribution, metabolism and excretion profiling of novel agrochemicals and pharmaceuticals. The different aspects of these studies (e.g. surgical preparation, dosing and collection of bile) can be intricate and/or technically complex. The animals are often kept singly housed for the duration of the studies following surgical implantation of the cannulas. The generation of insufficient data to meet the study objectives, for example due to failure in cannula patency, can result in the need to repeat these studies. A working group of contract research organizations that routinely carry out BDC studies was brought together by the National Centre for the Replacement, Refinement and Reduction of Animals in Research (NC3Rs) to share their experiences, and to establish the key factors necessary to ensure routinely high success rates. Through these discussions the group has identified opportunities for best practice across various aspects of the studies. The aim of these recommendations is to support all staff involved in conducting BDC studies to maximize the amount of useful data generated using the fewest animals possible, while ensuring the highest possible standards of animal welfare.
Fast effects of glucocorticoids on memory-related network oscillations in the mouse hippocampus.
Weiss, E K; Krupka, N; Bähner, F; Both, M; Draguhn, A
2008-05-01
Transient or lasting increases in glucocorticoids accompany deficits in hippocampus-dependent memory formation. Recent data indicate that the formation and consolidation of declarative and spatial memory are mechanistically related to different patterns of hippocampal network oscillations. These include gamma oscillations during memory acquisition and the faster ripple oscillations (approximately 200 Hz) during subsequent memory consolidation. We therefore analysed the effects of acutely applied glucocorticoids on network activity in mouse hippocampal slices. Evoked field population spikes and paired-pulse responses were largely unaltered by corticosterone or cortisol, respectively, despite a slight increase in maximal population spike amplitude by 10 microm corticosterone. Several characteristics of sharp waves and superimposed ripple oscillations were affected by glucocorticoids, most prominently the frequency of spontaneously occurring sharp waves. At 0.1 microm, corticosterone increased this frequency, whereas maximal (10 microm) concentrations led to a reduction. In addition, gamma oscillations became slightly faster and less regular in the presence of high doses of corticosteroids. The present study describes acute effects of glucocorticoids on sharp wave-ripple complexes and gamma oscillations in mouse hippocampal slices, revealing a potential background for memory deficits in the presence of elevated levels of these hormones.
Deininger, Michael W; Kopecky, Kenneth J; Radich, Jerald P; Kamel-Reid, Suzanne; Stock, Wendy; Paietta, Elisabeth; Emanuel, Peter D; Tallman, Martin; Wadleigh, Martha; Larson, Richard A; Lipton, Jeffrey H; Slovak, Marilyn L; Appelbaum, Frederick R; Druker, Brian J
2014-01-01
The standard dose of imatinib for newly diagnosed patients with chronic phase chronic myeloid leukaemia (CP-CML) is 400 mg daily (IM400), but the optimal dose is unknown. This randomized phase II study compared the rates of molecular, haematological and cytogenetic response to IM400 vs. imatinib 400 mg twice daily (IM800) in 153 adult patients with CP-CML. Dose adjustments for toxicity were flexible to maximize retention on study. Molecular response (MR) at 12 months was deeper in the IM800 arm (4-log reduction of BCR-ABL1 mRNA: 25% vs. 10% of patients, P = 0·038; 3-log reduction: 53% vs. 35%, P = 0·049). During the first 12 months BCR-ABL1 levels in the IM800 arm were an average 2·9-fold lower than in the IM400 arm (P = 0·010). Complete haematological response was similar, but complete cytogenetic response was higher with IM800 (85% vs. 67%, P = 0·040). Grade 3-4 toxicities were more common for IM800 (58% vs. 31%, P = 0·0007), and were most commonly haematological. Few patients have relapsed, progressed or died, but both progression-free (P = 0·048) and relapse-free (P = 0·031) survival were superior for IM800. In newly diagnosed CP-CML patients, IM800 induced deeper MRs than IM400, with a trend for improved progression-free and overall survival, but was associated with more severe toxicity. © 2013 John Wiley & Sons Ltd.
Combination therapy for type 2 diabetes: repaglinide plus rosiglitazone.
Raskin, P; McGill, J; Saad, M F; Cappleman, J M; Kaye, W; Khutoryansky, N; Hale, P M
2004-04-01
This 24-week, randomized, multicentre, open-label, parallel-group clinical trial compared efficacy and safety of repaglinide monotherapy, rosiglitazone monotherapy, and combination therapy (repaglinide plus rosiglitazone) in Type 2 diabetes after unsatisfactory response to sulphonylurea or metformin monotherapy. Enrolled patients (n = 252) were adults having Type 2 diabetes for at least 1 year, with HbA(1c) values > 7.0% after previous monotherapy (sulphonylurea or metformin, >/= 50% maximal dose). Prior therapy was withdrawn for 2 weeks, followed by randomization to repaglinide, rosiglitazone, or repaglinide/rosiglitazone. Study treatments were initiated with a 12-week dose optimization period (doses optimized according to labelling), followed by a 12-week maintenance period. Efficacy endpoints were changes in HbA(1c) values (primary) or fasting plasma glucose values (secondary). Baseline HbA(1c) values were comparable (9.3% for repaglinide, 9.0% for rosiglitazone, 9.1% for combination). Mean changes in HbA(1c) values at the end of treatment were greater for repaglinide/rosiglitazone therapy (-1.43%) than for repaglinide (-0.17%) or rosiglitazone (-0.56%) monotherapy. Reductions of fasting plasma glucose values were also greater for combination therapy (-5.2 mmol/l, -94 mg/dl) than for repaglinide monotherapy (-3.0 mmol/l, -54 mg/dl) or rosiglitazone monotherapy (-3.7 mmol/l, -67 mg/dl). Minor hypoglycaemic events occurred in 9% of combination therapy patients, vs. 6% for repaglinide and 2% for rosiglitazone. Individual weight gains for combination therapy were correlated to HbA(1c) response. The combination therapy regimen was well tolerated. In patients previously showing unsatisfactory response to oral monotherapy, glycaemic reductions were greater for the repaglinide/rosiglitazone combination regimen than for use of either repaglinide or rosiglitazone alone.
Hohmann, Miriam S N; Cardoso, Renato D R; Fattori, Victor; Arakawa, Nilton S; Tomaz, José C; Lopes, Norberto P; Casagrande, Rubia; Verri, Waldiceu A
2015-07-01
Hypericum perforatum is a medicinal plant with anti-inflammatory and antioxidant properties, which is commercially available for therapeutic use in Brazil. Herein the effect of H. perforatum extract on paracetamol (acetaminophen)-induced hepatotoxicity, lethality, inflammation, and oxidative stress in male swiss mice were investigated. HPLC analysis demonstrated the presence of rutin, quercetin, hypericin, pseudohypericin, and hyperforin in H. perforatum extract. Paracetamol (0.15-3.0 g/kg, p.o.) induced dose-dependent mortality. The sub-maximal lethal dose of paracetamol (1.5 g/kg, p.o.) was chosen for the experiments in the study. H. perforatum (30-300 mg/kg, i.p.) dose-dependently reduced paracetamol-induced lethality. Paracetamol-induced increase in plasma aspartate aminotransferase (AST) and alanine aminotransferase (ALT) concentrations, and hepatic myeloperoxidase activity, IL-1β, TNF-α, and IFN-γ concentrations as well as decreased reduced glutathione (GSH) concentrations and capacity to reduce 2,2'-azinobis-(3-ethylbenzothiazoline-6-sulfonate radical cation; ABTS˙(+) ) were inhibited by H. perforatum (300 mg/kg, i.p.) treatment. Therefore, H. perforatum protects mice against paracetamol-induced lethality and liver damage. This effect seems to be related to the reduction of paracetamol-induced cytokine production, neutrophil recruitment, and oxidative stress. Copyright © 2015 John Wiley & Sons, Ltd.
Geary, Richard S; Baker, Brenda F; Crooke, Stanley T
2015-02-01
Mipomersen (Kynamro(®)), a second-generation 2'-O-methoxyethyl chimeric antisense oligonucleotide (ASO), inhibits the synthesis of apolipoprotein B (apoB) and is indicated in the US as an adjunct therapy for homozygous familial hypercholesterolemia (HoFH) at a dose of 200 mg subcutaneously (SC) once weekly. The pharmacokinetic (PK) properties of mipomersen are generally consistent across all species studied, including mouse, rat, monkey, and humans. After SC administration, mipomersen is rapidly and extensively absorbed. It has an apparent plasma and tissue terminal elimination half-life of approximately 30 days. Mipomersen achieves steady-state tissue concentrations within approximately 4-6 months of once-weekly dosing. It does not exhibit PK-based drug-drug interactions with other concomitant medications, either involving competition for plasma protein binding or alterations in disposition of any evaluated drugs. Furthermore, mipomersen does not prolong the corrected QT (QTc) interval. There have been no ethnic- or gender-related differences in PK observed. In clinical trials, both as a single agent and in the presence of maximal lipid-lowering therapy, mipomersen has demonstrated significant dose-dependent reductions in all measured apoB-containing atherogenic lipoproteins. Overall, mipomersen has well-characterized PK and pharmacodynamic properties in both animals and humans, and is an efficacious adjunct treatment for patients with HoFH.
Almorexant promotes sleep and exacerbates cataplexy in a murine model of narcolepsy.
Black, Sarah Wurts; Morairty, Stephen R; Fisher, Simon P; Chen, Tsui-Ming; Warrier, Deepti R; Kilduff, Thomas S
2013-03-01
Humans with narcolepsy and orexin/ataxin-3 transgenic (TG) mice exhibit extensive, but incomplete, degeneration of hypo-cretin (Hcrt) neurons. Partial Hcrt cell loss also occurs in Parkinson disease and other neurologic conditions. Whether Hcrt antagonists such as almorexant (ALM) can exert an effect on the Hcrt that remains after Hcrt neurodegeneration has not yet been determined. The current study was designed to evaluate the hypnotic and cataplexy-inducing efficacy of a Hcrt antagonist in an animal model with low Hcrt tone and compare the ALM efficacy profile in the disease model to that produced in wild-type (WT) control animals. Counterbalanced crossover study. Home cage. Nine TG mice and 10 WT mice. ALM (30, 100, 300 mg/kg), vehicle and positive control injections, dark/active phase onset. During the 12-h dark period after dosing, ALM exacerbated cataplexy in TG mice and increased nonrapid eye movement sleep with heightened sleep/wake fragmentation in both genotypes. ALM showed greater hypnotic potency in WT mice than in TG mice. The 100 mg/kg dose conferred maximal promotion of cataplexy in TG mice and maximal promotion of REM sleep in WT mice. In TG mice, ALM (30 mg/ kg) paradoxically induced a transient increase in active wakefulness. Core body temperature (Tb) decreased after acute Hcrt receptor blockade, but the reduction in Tb that normally accompanies the wake-to-sleep transition was blunted in TG mice. These complex dose- and genotype-dependent interactions underscore the importance of effector mechanisms downstream from Hcrt receptors that regulate arousal state. Cataplexy promotion by ALM warrants cautious use of Hcrt antagonists in patient populations with Hcrt neurodegeneration, but may also facilitate the discovery of anticataplectic medications. Black SW; Morairty SR; Fisher SP; Chen TM; Warrier DR; Kilduff TS. Almorexant promotes sleep and exacerbates cataplexy in a murine model of narcolepsy. SLEEP 2013;36(3):325-336.
Caoili, Salvador Eugenio C.
2014-01-01
B-cell epitope prediction can enable novel pharmaceutical product development. However, a mechanistically framed consensus has yet to emerge on benchmarking such prediction, thus presenting an opportunity to establish standards of practice that circumvent epistemic inconsistencies of casting the epitope prediction task as a binary-classification problem. As an alternative to conventional dichotomous qualitative benchmark data, quantitative dose-response data on antibody-mediated biological effects are more meaningful from an information-theoretic perspective in the sense that such effects may be expressed as probabilities (e.g., of functional inhibition by antibody) for which the Shannon information entropy (SIE) can be evaluated as a measure of informativeness. Accordingly, half-maximal biological effects (e.g., at median inhibitory concentrations of antibody) correspond to maximally informative data while undetectable and maximal biological effects correspond to minimally informative data. This applies to benchmarking B-cell epitope prediction for the design of peptide-based immunogens that elicit antipeptide antibodies with functionally relevant cross-reactivity. Presently, the Immune Epitope Database (IEDB) contains relatively few quantitative dose-response data on such cross-reactivity. Only a small fraction of these IEDB data is maximally informative, and many more of them are minimally informative (i.e., with zero SIE). Nevertheless, the numerous qualitative data in IEDB suggest how to overcome the paucity of informative benchmark data. PMID:24949474
The key kinematic determinants of undulatory underwater swimming at maximal velocity.
Connaboy, Chris; Naemi, Roozbeh; Brown, Susan; Psycharakis, Stelios; McCabe, Carla; Coleman, Simon; Sanders, Ross
2016-01-01
The optimisation of undulatory underwater swimming is highly important in competitive swimming performance. Nineteen kinematic variables were identified from previous research undertaken to assess undulatory underwater swimming performance. The purpose of the present study was to determine which kinematic variables were key to the production of maximal undulatory underwater swimming velocity. Kinematic data at maximal undulatory underwater swimming velocity were collected from 17 skilled swimmers. A series of separate backward-elimination analysis of covariance models was produced with cycle frequency and cycle length as dependent variables (DVs) and participant as a fixed factor, as including cycle frequency and cycle length would explain 100% of the maximal swimming velocity variance. The covariates identified in the cycle-frequency and cycle-length models were used to form the saturated model for maximal swimming velocity. The final parsimonious model identified three covariates (maximal knee joint angular velocity, maximal ankle angular velocity and knee range of movement) as determinants of the variance in maximal swimming velocity (adjusted-r2 = 0.929). However, when participant was removed as a fixed factor there was a large reduction in explained variance (adjusted r2 = 0.397) and only maximal knee joint angular velocity continued to contribute significantly, highlighting its importance to the production of maximal swimming velocity. The reduction in explained variance suggests an emphasis on inter-individual differences in undulatory underwater swimming technique and/or anthropometry. Future research should examine the efficacy of other anthropometric, kinematic and coordination variables to better understand the production of maximal swimming velocity and consider the importance of individual undulatory underwater swimming techniques when interpreting the data.
Yoon, Jihyung; Xie, Yibo; Zhang, Rui
2018-03-01
The purpose of this study was to evaluate a methodology to reduce scatter and leakage radiations to patients' surface and shallow depths during conventional and advanced external beam radiotherapy. Superflab boluses of different thicknesses were placed on top of a stack of solid water phantoms, and the bolus effect on surface and shallow depth doses for both open and intensity-modulated radiotherapy (IMRT) beams was evaluated using thermoluminescent dosimeters and ion chamber measurements. Contralateral breast dose reduction caused by the bolus was evaluated by delivering clinical postmastectomy radiotherapy (PMRT) plans to an anthropomorphic phantom. For the solid water phantom measurements, surface dose reduction caused by the Superflab bolus was achieved only in out-of-field area and on the incident side of the beam, and the dose reduction increased with bolus thickness. The dose reduction caused by the bolus was more significant at closer distances from the beam. Most of the dose reductions occurred in the first 2-cm depth and stopped at 4-cm depth. For clinical PMRT treatment plans, surface dose reductions using a 1-cm Superflab bolus were up to 31% and 62% for volumetric-modulated arc therapy and 4-field IMRT, respectively, but there was no dose reduction for Tomotherapy. A Superflab bolus can be used to reduce surface and shallow depth doses during external beam radiotherapy when it is placed out of the beam and on the incident side of the beam. Although we only validated this dose reduction strategy for PMRT treatments, it is applicable to any external beam radiotherapy and can potentially reduce patients' risk of developing radiation-induced side effects. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Assessment of female breast dose for thoracic cone-beam CT using MOSFET dosimeters.
Sun, Wenzhao; Wang, Bin; Qiu, Bo; Liang, Jian; Xie, Weihao; Deng, Xiaowu; Qi, Zhenyu
2017-03-21
To assess the breast dose during a routine thoracic cone-beam CT (CBCT) check with the efforts to explore the possible dose reduction strategy. Metal oxide semiconductor field-effect transistor (MOSFET) dosimeters were used to measure breast surface doses during a thorax kV CBCT scan in an anthropomorphic phantom. Breast doses for different scanning protocols and breast sizes were compared. Dose reduction was attempted by using partial arc CBCT scan with bowtie filter. The impact of this dose reduction strategy on image registration accuracy was investigated. The average breast surface doses were 20.02 mGy and 11.65 mGy for thoracic CBCT without filtration and with filtration, respectively. This indicates a dose reduction of 41.8% by use of bowtie filter. It was found 220° partial arc scanning significantly reduced the dose to contralateral breast (44.4% lower than ipsilateral breast), while the image registration accuracy was not compromised. Breast dose reduction can be achieved by using ipsilateral 220° partial arc scan with bowtie filter. This strategy also provides sufficient image quality for thorax image registration in daily patient positioning verification.
Protecting marine mammals, turtles, and birds by rebuilding global fisheries.
Burgess, Matthew G; McDermott, Grant R; Owashi, Brandon; Peavey Reeves, Lindsey E; Clavelle, Tyler; Ovando, Daniel; Wallace, Bryan P; Lewison, Rebecca L; Gaines, Steven D; Costello, Christopher
2018-03-16
Reductions in global fishing pressure are needed to end overfishing of target species and maximize the value of fisheries. We ask whether such reductions would also be sufficient to protect non-target species threatened as bycatch. We compare changes in fishing pressure needed to maximize profits from 4713 target fish stocks-accounting for >75% of global catch-to changes in fishing pressure needed to reverse ongoing declines of 20 marine mammal, sea turtle, and seabird populations threatened as bycatch. We project that maximizing fishery profits would halt or reverse declines of approximately half of these threatened populations. Recovering the other populations would require substantially greater effort reductions or targeting improvements. Improving commercial fishery management could thus yield important collateral benefits for threatened bycatch species globally. Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.
The Role of Autocrine-Paracrine Cascades in Breast Tumor Metastasis
1999-08-01
tested a large series of anti-oxidants at non- toxic doses. The only compounds that worked in this series were resveratrol and curcumin . The...resveratrol gave a 20-35% maximal inhibition while the curcumin gave a maximal response between 40 and 60% maximal inhibition. While the resveratrol inhibited...IL-8 expression in both -7- THIS REPORT CONTAINS PROPRIETARY AND/OR UNPUBLISHED DATA the MD-231 and MD-435s cells, the inhibitory effects of curcumin
Tondi, Lara; Fragasso, Gabriele; Spoladore, Roberto; Pinto, Giuseppe; Gemma, Marco; Slavich, Massimo; Godino, Cosmo; Salerno, Anna; Montanaro, Claudia; Margonato, Alberto
2018-05-11
: Ivabradine is a selective and specific inhibitor of If current. With its pure negative chronotropic action, it is recommended by European Society of Cardiology and American College of Cardiology/American Heart Association guidelines in symptomatic heart failure patients (NYHA ≥ 2) with ejection fraction 35% or less, sinus rhythm and heart rate (HR) at least 70 bpm, despite maximally titrated β-blocker therapy. Data supporting this indication mainly derive from the SHIFT study, in which ivabradine reduced the combined endpoint of mortality and hospitalization, despite the fact that only 26% of patients enrolled were on optimal β-blocker doses. The aim of the present analysis is to establish the real-life eligibility for ivabradine in a population of patients with systolic heart failure, regularly attending a single heart failure clinic and treated according to guideline-directed medical therapy (GDMT). The clinical cards of 308 patients with heart failure with reduced ejection fraction (HFrEF) through a 68-month period of observation were retrospectively analyzed. GDMT, including β-blocker up-titration to maximal tolerated dose, was implemented during consecutive visits at variable intervals. Demographic, clinical and echocardiographic data were collected at each visit, together with 12-leads ECG and N-terminal pro-B-type natriuretic peptide levels. Out of 308 analyzed HFrEF patients, 220 (71%) were on effective β-blocker therapy, up-titrated to effective/maximal tolerated dose (55 ± 28% of maximal dose) (HR 67 ± 10 bpm). Among the remaining 88 patients, 10 (3.2%) were on maximally tolerated β blocker and ivabradine; 21 patients (6.8%), despite being on maximal tolerated β-blocker dose, had still HR ≥70 bpm, ejection fraction 35% or less and were symptomatic NYHA ≥2, being therefore eligible for ivabradine treatment. The remaining 57 (18%) patients were not on β blocker due to either intolerance or major contraindications. Among them, 13 (4%) were taking ivabradine alone. Of the final 44 (14%) patients, 27 (9%) showed an inadequate HR control (74 ± 6 bpm). Of these, only eight (3%) patients resulted to be eligible for ivabradine introduction according to HR and ejection fraction parameters. Overall ivabradine was indicated in 52 patients (16.8%) out of 308 enrolled.In conclusion, in a carefully managed population of patients with moderate and stable HFrEF, in which optimal GDMT is properly attained, indication to ivabradine treatment is around 17%.
NASA Astrophysics Data System (ADS)
Lee, Boram; Lee, Sunyoung; Yang, Injeong; Yoon, Myeonggeun
2014-05-01
The purpose of this study is to evaluate the dose reduction when using the stepwise collimation method for scoliosis patients undergoing full spine radiography. A Monte Carlo simulation was carried out to acquire dose vs. volume data for organs at risk (OAR) in the human body. While the effective doses in full spine radiography were reduced by 8, 15, 27 and 44% by using four different sizes of the collimation, the doses to the skin were reduced by 31, 44, 55 and 66%, indicating that the reduction of the dose to the skin is higher than that to organs inside the body. Although the reduction rates were low for the gonad, being 9, 14, 18 and 23%, there was more than a 30% reduction in the dose to the heart, suggesting that the dose reduction depends significantly on the location of the OARs in the human body. The reduction rate of the secondary cancer risk based on the excess absolute risk (EAR) varied from 0.6 to 3.4 per 10,000 persons, depending on the size of the collimation. Our results suggest that the stepwise collimation method in full spine radiography can effectively reduce the patient dose and the radiation-induced secondary cancer risk.
Mickle, Travis C; Guenther, Sven M; Barrett, Andrew C; Roupe, Kathryn Ann; Zhou, Jing; Dickerson, Daniel; Webster, Lynn R
2017-10-28
Developing an acetaminophen-free, immediate-release hydrocodone product remains an unmet medical need; however, new opioid analgesics should not introduce new abuse risks. Benzhydrocodone is a prodrug of hydrocodone that must be metabolized into hydrocodone by enzymes in the intestinal tract to optimally deliver its pharmacologic effects. This study evaluated the intranasal pharmacokinetics and abuse potential of benzhydrocodone active pharmaceutical ingredient (API) compared with hydrocodone bitartrate (HB) API. Single-center, randomized, double-blind, crossover study. Clinical research site. Healthy adult, nondependent, recreational opioid users. Subjects (N = 51 Completers) were randomized to receive 13.34 mg of intranasal benzhydrocodone API and 15.0 mg of intranasal HB API (molar-equivalent doses of hydrocodone). Blood samples were taken, and Drug Liking scores (assessed on a bipolar visual analog scale) were obtained throughout each dosing interval. Nasal irritation and safety were assessed. Peak hydrocodone plasma concentration (Cmax) was 36.0% lower, and total hydrocodone exposures (AUClast and AUCinf) were 20.3% and 19.5% lower, respectively, for benzhydrocodone API compared with HB API (P < 0.0001). All partial AUC values were lower for benzhydrocodone API, with a ≥ 75% reduction in hydrocodone exposure at all time intervals up to one hour postdose (P < 0.0001). Median Tmax of hydrocodone following benzhydrocodone API was delayed by more than one hour compared with HB. Drug Liking score, as assessed by maximal liking (Emax), was significantly lower for benzhydrocodone API vs HB API (P = 0.004), with 45% of subjects showing a ≥ 30% reduction in Drug Liking Emax. Reductions in hydrocodone exposure and associated decreases in Drug Liking relative to HB suggest that the prodrug benzhydrocodone may deter intranasal abuse. © 2017 American Academy of Pain Medicine.
Racz, Boglarka; Varadi, Andras; Kong, Jian; Allikmets, Rando; Pearson, Paul G; Johnson, Graham; Cioffi, Christopher L; Petrukhin, Konstantin
2018-06-05
A primary pathological defect in the heritable eye disorder Stargardt disease is excessive accumulation of cytotoxic lipofuscin bisretinoids in the retina. Age-dependent accumulation of lipofuscin in the retinal pigment epithelium (RPE) matches the age-dependent increase in the incidence of the atrophic (dry) form of age-related macular degeneration (AMD) and therefore may be one of several pathogenic factors contributing to AMD progression. Lipofuscin bisretinoid synthesis in the retina depends on the influx of serum retinol from the circulation into the RPE. Formation of the tertiary retinol-binding protein 4 (RBP4)-transthyretin-retinol complex in the serum is required for this influx. Herein, we report the pharmacological effects of the non-retinoid RBP4 antagonist, BPN-14136. BPN-14136 dosing in the Abca4-/- mouse model of increased lipofuscinogenesis significantly reduced serum RBP4 levels and inhibited bisretinoid synthesis, and this inhibition correlated with a partial reduction in visual cycle retinoids such as retinaldehydes serving as bisretinoid precursors. BPN-14136 administration at doses inducing maximal serum RBP4 reduction did not produce changes in the rate of the visual cycle, consistent with minimal changes in dark adaptation. Abca4-/- mice exhibited dysregulation of the complement system in the retina, and BPN-14136 administration normalized the retinal levels of proinflammatory complement cascade components such as complement factors D and H, C-reactive protein, and C3. We conclude that BPN-14136 has several beneficial characteristics, combining inhibition of bisretinoid synthesis and reduction in retinaldehydes with normalization of the retinal complement system. BPN-14136, or a similar compound, may be a promising drug candidate to manage Stargardt disease and dry AMD. Published under license by The American Society for Biochemistry and Molecular Biology, Inc.
Radiation dose reduction in medical x-ray CT via Fourier-based iterative reconstruction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fahimian, Benjamin P.; Zhao Yunzhe; Huang Zhifeng
Purpose: A Fourier-based iterative reconstruction technique, termed Equally Sloped Tomography (EST), is developed in conjunction with advanced mathematical regularization to investigate radiation dose reduction in x-ray CT. The method is experimentally implemented on fan-beam CT and evaluated as a function of imaging dose on a series of image quality phantoms and anonymous pediatric patient data sets. Numerical simulation experiments are also performed to explore the extension of EST to helical cone-beam geometry. Methods: EST is a Fourier based iterative algorithm, which iterates back and forth between real and Fourier space utilizing the algebraically exact pseudopolar fast Fourier transform (PPFFT). Inmore » each iteration, physical constraints and mathematical regularization are applied in real space, while the measured data are enforced in Fourier space. The algorithm is automatically terminated when a proposed termination criterion is met. Experimentally, fan-beam projections were acquired by the Siemens z-flying focal spot technology, and subsequently interleaved and rebinned to a pseudopolar grid. Image quality phantoms were scanned at systematically varied mAs settings, reconstructed by EST and conventional reconstruction methods such as filtered back projection (FBP), and quantified using metrics including resolution, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs). Pediatric data sets were reconstructed at their original acquisition settings and additionally simulated to lower dose settings for comparison and evaluation of the potential for radiation dose reduction. Numerical experiments were conducted to quantify EST and other iterative methods in terms of image quality and computation time. The extension of EST to helical cone-beam CT was implemented by using the advanced single-slice rebinning (ASSR) method. Results: Based on the phantom and pediatric patient fan-beam CT data, it is demonstrated that EST reconstructions with the lowest scanner flux setting of 39 mAs produce comparable image quality, resolution, and contrast relative to FBP with the 140 mAs flux setting. Compared to the algebraic reconstruction technique and the expectation maximization statistical reconstruction algorithm, a significant reduction in computation time is achieved with EST. Finally, numerical experiments on helical cone-beam CT data suggest that the combination of EST and ASSR produces reconstructions with higher image quality and lower noise than the Feldkamp Davis and Kress (FDK) method and the conventional ASSR approach. Conclusions: A Fourier-based iterative method has been applied to the reconstruction of fan-bean CT data with reduced x-ray fluence. This method incorporates advantageous features in both real and Fourier space iterative schemes: using a fast and algebraically exact method to calculate forward projection, enforcing the measured data in Fourier space, and applying physical constraints and flexible regularization in real space. Our results suggest that EST can be utilized for radiation dose reduction in x-ray CT via the readily implementable technique of lowering mAs settings. Numerical experiments further indicate that EST requires less computation time than several other iterative algorithms and can, in principle, be extended to helical cone-beam geometry in combination with the ASSR method.« less
Radiation dose reduction in medical x-ray CT via Fourier-based iterative reconstruction.
Fahimian, Benjamin P; Zhao, Yunzhe; Huang, Zhifeng; Fung, Russell; Mao, Yu; Zhu, Chun; Khatonabadi, Maryam; DeMarco, John J; Osher, Stanley J; McNitt-Gray, Michael F; Miao, Jianwei
2013-03-01
A Fourier-based iterative reconstruction technique, termed Equally Sloped Tomography (EST), is developed in conjunction with advanced mathematical regularization to investigate radiation dose reduction in x-ray CT. The method is experimentally implemented on fan-beam CT and evaluated as a function of imaging dose on a series of image quality phantoms and anonymous pediatric patient data sets. Numerical simulation experiments are also performed to explore the extension of EST to helical cone-beam geometry. EST is a Fourier based iterative algorithm, which iterates back and forth between real and Fourier space utilizing the algebraically exact pseudopolar fast Fourier transform (PPFFT). In each iteration, physical constraints and mathematical regularization are applied in real space, while the measured data are enforced in Fourier space. The algorithm is automatically terminated when a proposed termination criterion is met. Experimentally, fan-beam projections were acquired by the Siemens z-flying focal spot technology, and subsequently interleaved and rebinned to a pseudopolar grid. Image quality phantoms were scanned at systematically varied mAs settings, reconstructed by EST and conventional reconstruction methods such as filtered back projection (FBP), and quantified using metrics including resolution, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs). Pediatric data sets were reconstructed at their original acquisition settings and additionally simulated to lower dose settings for comparison and evaluation of the potential for radiation dose reduction. Numerical experiments were conducted to quantify EST and other iterative methods in terms of image quality and computation time. The extension of EST to helical cone-beam CT was implemented by using the advanced single-slice rebinning (ASSR) method. Based on the phantom and pediatric patient fan-beam CT data, it is demonstrated that EST reconstructions with the lowest scanner flux setting of 39 mAs produce comparable image quality, resolution, and contrast relative to FBP with the 140 mAs flux setting. Compared to the algebraic reconstruction technique and the expectation maximization statistical reconstruction algorithm, a significant reduction in computation time is achieved with EST. Finally, numerical experiments on helical cone-beam CT data suggest that the combination of EST and ASSR produces reconstructions with higher image quality and lower noise than the Feldkamp Davis and Kress (FDK) method and the conventional ASSR approach. A Fourier-based iterative method has been applied to the reconstruction of fan-bean CT data with reduced x-ray fluence. This method incorporates advantageous features in both real and Fourier space iterative schemes: using a fast and algebraically exact method to calculate forward projection, enforcing the measured data in Fourier space, and applying physical constraints and flexible regularization in real space. Our results suggest that EST can be utilized for radiation dose reduction in x-ray CT via the readily implementable technique of lowering mAs settings. Numerical experiments further indicate that EST requires less computation time than several other iterative algorithms and can, in principle, be extended to helical cone-beam geometry in combination with the ASSR method.
Radiation dose reduction in medical x-ray CT via Fourier-based iterative reconstruction
Fahimian, Benjamin P.; Zhao, Yunzhe; Huang, Zhifeng; Fung, Russell; Mao, Yu; Zhu, Chun; Khatonabadi, Maryam; DeMarco, John J.; Osher, Stanley J.; McNitt-Gray, Michael F.; Miao, Jianwei
2013-01-01
Purpose: A Fourier-based iterative reconstruction technique, termed Equally Sloped Tomography (EST), is developed in conjunction with advanced mathematical regularization to investigate radiation dose reduction in x-ray CT. The method is experimentally implemented on fan-beam CT and evaluated as a function of imaging dose on a series of image quality phantoms and anonymous pediatric patient data sets. Numerical simulation experiments are also performed to explore the extension of EST to helical cone-beam geometry. Methods: EST is a Fourier based iterative algorithm, which iterates back and forth between real and Fourier space utilizing the algebraically exact pseudopolar fast Fourier transform (PPFFT). In each iteration, physical constraints and mathematical regularization are applied in real space, while the measured data are enforced in Fourier space. The algorithm is automatically terminated when a proposed termination criterion is met. Experimentally, fan-beam projections were acquired by the Siemens z-flying focal spot technology, and subsequently interleaved and rebinned to a pseudopolar grid. Image quality phantoms were scanned at systematically varied mAs settings, reconstructed by EST and conventional reconstruction methods such as filtered back projection (FBP), and quantified using metrics including resolution, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs). Pediatric data sets were reconstructed at their original acquisition settings and additionally simulated to lower dose settings for comparison and evaluation of the potential for radiation dose reduction. Numerical experiments were conducted to quantify EST and other iterative methods in terms of image quality and computation time. The extension of EST to helical cone-beam CT was implemented by using the advanced single-slice rebinning (ASSR) method. Results: Based on the phantom and pediatric patient fan-beam CT data, it is demonstrated that EST reconstructions with the lowest scanner flux setting of 39 mAs produce comparable image quality, resolution, and contrast relative to FBP with the 140 mAs flux setting. Compared to the algebraic reconstruction technique and the expectation maximization statistical reconstruction algorithm, a significant reduction in computation time is achieved with EST. Finally, numerical experiments on helical cone-beam CT data suggest that the combination of EST and ASSR produces reconstructions with higher image quality and lower noise than the Feldkamp Davis and Kress (FDK) method and the conventional ASSR approach. Conclusions: A Fourier-based iterative method has been applied to the reconstruction of fan-bean CT data with reduced x-ray fluence. This method incorporates advantageous features in both real and Fourier space iterative schemes: using a fast and algebraically exact method to calculate forward projection, enforcing the measured data in Fourier space, and applying physical constraints and flexible regularization in real space. Our results suggest that EST can be utilized for radiation dose reduction in x-ray CT via the readily implementable technique of lowering mAs settings. Numerical experiments further indicate that EST requires less computation time than several other iterative algorithms and can, in principle, be extended to helical cone-beam geometry in combination with the ASSR method. PMID:23464329
Henninger, Heath B; Valdez, William R; Scott, Sara A; Weiss, Jeffrey A
2015-10-01
Elastin is a highly extensible structural protein network that provides near-elastic resistance to deformation in biological tissues. In ligament, elastin is localized between and along the collagen fibers and fascicles. When ligament is stretched along the primary collagen axis, elastin supports a relatively high percentage of load. We hypothesized that elastin may also provide significant load support under elongation transverse to the primary collagen axis and shear along the collagen axis. Quasi-static transverse tensile and shear material tests were performed to quantify the mechanical contributions of elastin during deformation of porcine medial collateral ligament. Dose response studies were conducted to determine the level of elastase enzymatic degradation required to produce a maximal change in the mechanical response. Maximal changes in peak stress occurred after 3h of treatment with 2U/ml porcine pancreatic elastase. Elastin degradation resulted in a 60-70% reduction in peak stress and a 2-3× reduction in modulus for both test protocols. These results demonstrate that elastin provides significant resistance to elongation transverse to the collagen axis and shear along the collagen axis while only constituting 4% of the tissue dry weight. The magnitudes of the elastin contribution to peak transverse and shear stress were approximately 0.03 MPa, as compared to 2 MPa for axial tensile tests, suggesting that elastin provides a highly anisotropic contribution to the mechanical response of ligament and is the dominant structural protein resisting transverse and shear deformation of the tissue. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin Jing; Li Yexiong; Wang Jinwan
Purpose: A Phase I study was conducted to determine the maximal tolerated dose and the dose-limiting toxicity (DLT) of oxaliplatin (OXA) combined with capecitabine and radiotherapy as adjuvant treatment in patients with operable rectal cancer. Patients and Methods: A total of 21 patients with Stage II or III rectal adenocarcinoma after curative surgery were treated with radiotherapy to a total dose of 50 Gy in 5 weeks. OXA was administered at a dosage of 40 (n = 6), 50 (n = 3),60 (n = 3), 70 (n = 3), or 80 mg/m{sup 2} (n = 6) once a week formore » 2 weeks (first cycle) followed by a second cycle after a 7-day break. Capecitabine at a fixed dose of 1,300 mg/m{sup 2}/d was administered orally at the same schedule as for OXA. DLT was defined as Grade 3 or 4 hematologic and nonhematologic toxicity. Results: Grade 1-3 leukopenia, diarrhea, and nausea/vomiting were the most common toxic side effects, and most were Grade 1-2. A DLT was first observed in 1 of 3 patients at 40 mg/m{sup 2} (Grade 3 diarrhea) but was not observed in the next 3 patients at the same level or in patients who received a dose level of 50-70 mg/m{sup 2}. At 80 mg/m{sup 2}, DLT occurred in 3 of 6 patients (1 Grade 4 leukopenia and 2 Grade 3 diarrhea). Conclusions: OXA combined with a fixed dose of capecitabine at 625 mg/m{sup 2} twice daily by mouth plus radiotherapy in the adjuvant setting was tolerable and clinically feasible. The maximal tolerated dose of OXA in this setting was 80 mg/m{sup 2}, comparable to the maximal tolerated dose of OXA in the neoadjuvant setting.« less
Cao, Ying J; Caffo, Brian S; Fuchs, Edward J; Lee, Linda A; Du, Yong; Li, Liye; Bakshi, Rahul P; Macura, Katarzyna; Khan, Wasif A; Wahl, Richard L; Grohskopf, Lisa A; Hendrix, Craig W
2012-01-01
AIMS We sought to describe quantitatively the distribution of rectally administered gels and seminal fluid surrogates using novel concentration–distance parameters that could be repeated over time. These methods are needed to develop rationally rectal microbicides to target and prevent HIV infection. METHODS Eight subjects were dosed rectally with radiolabelled and gadolinium-labelled gels to simulate microbicide gel and seminal fluid. Rectal doses were given with and without simulated receptive anal intercourse. Twenty-four hour distribution was assessed with indirect single photon emission computed tomography (SPECT)/computed tomography (CT) and magnetic resonance imaging (MRI), and direct assessment via sigmoidoscopic brushes. Concentration–distance curves were generated using an algorithm for fitting SPECT data in three dimensions. Three novel concentration–distance parameters were defined to describe quantitatively the distribution of radiolabels: maximal distance (Dmax), distance at maximal concentration (DCmax) and mean residence distance (Dave). RESULTS The SPECT/CT distribution of microbicide and semen surrogates was similar. Between 1 h and 24 h post dose, the surrogates migrated retrograde in all three parameters (relative to coccygeal level; geometric mean [95% confidence interval]): maximal distance (Dmax), 10 cm (8.6–12) to 18 cm (13–26), distance at maximal concentration (DCmax), 3.8 cm (2.7–5.3) to 4.2 cm (2.8–6.3) and mean residence distance (Dave), 4.3 cm (3.5–5.1) to 7.6 cm (5.3–11). Sigmoidoscopy and MRI correlated only roughly with SPECT/CT. CONCLUSIONS Rectal microbicide surrogates migrated retrograde during the 24 h following dosing. Spatial kinetic parameters estimated using three dimensional curve fitting of distribution data should prove useful for evaluating rectal formulations of drugs for HIV prevention and other indications. PMID:22404308
Pharmacokinetics of detomidine administered to horses at rest and after maximal exercise.
Hubbell, J A E; Sams, R A; Schmall, L M; Robertson, J T; Hinchcliff, K W; Muir, W W
2009-05-01
Increased doses of detomidine are required to produce sedation in horses after maximal exercise compared to calm or resting horses. To determine if the pharmacokinetics of detomidine in Thoroughbred horses are different when the drug is given during recuperation from a brief period of maximal exercise compared to administration at rest. Six Thoroughbred horses were preconditioned by exercising them on a treadmill. Each horse ran a simulated race at a treadmill speed that caused it to exercise at 120% of its maximal oxygen consumption. One minute after the end of exercise, horses were treated with detomidine. Each horse was treated with the same dose of detomidine on a second occasion a minimum of 14 days later while standing in a stocks. Samples of heparinised blood were obtained at various time points on both occasions. Plasma detomidine concentrations were determined by liquid chromatography-mass spectrometry. The plasma concentration vs. time data were analysed by nonlinear regression analysis. Median back-extrapolated time zero plasma concentration was significantly lower and median plasma half-life and median mean residence time were significantly longer when detomidine was administered after exercise compared to administration at rest. Median volume of distribution was significantly higher after exercise but median plasma clearance was not different between the 2 administrations. Detomidine i.v. is more widely distributed when administered to horses immediately after exercise compared to administration at rest resulting in lower peak plasma concentrations and a slower rate of elimination. The dose requirement to produce an equivalent effect may be higher in horses after exercise than in resting horses and less frequent subsequent doses may be required to produce a sustained effect.
Iglarz, Marc; Bossu, Alexandre; Wanner, Daniel; Bortolamiol, Céline; Rey, Markus; Hess, Patrick; Clozel, Martine
2014-11-24
The endothelin (ET) system is a tissular system, as the production of ET isoforms is mostly autocrine or paracrine. Macitentan is a novel dual ETA/ETB receptor antagonist with enhanced tissue distribution and sustained receptor binding properties designed to achieve a more efficacious ET receptor blockade. To determine if these features translate into improved efficacy in vivo, a study was designed in which rats with either systemic or pulmonary hypertension and equipped with telemetry were given macitentan on top of maximally effective doses of another dual ETA/ETB receptor antagonist, bosentan, which does not display sustained receptor occupancy and shows less tissue distribution. After establishing dose-response curves of both compounds in conscious, hypertensive Dahl salt-sensitive and pulmonary hypertensive bleomycin-treated rats, macitentan was administered on top of the maximal effective dose of bosentan. In hypertensive rats, macitentan 30 mg/kg further decreased mean arterial blood pressure (MAP) by 19 mm Hg when given on top of bosentan 100 mg/kg (n=9, p<0.01 vs. vehicle). Conversely, bosentan given on top of macitentan failed to induce an additional MAP decrease. In pulmonary hypertensive rats, macitentan 30 mg/kg further decreased mean pulmonary artery pressure (MPAP) by 4 mm Hg on top of bosentan (n=8, p<0.01 vs. vehicle), whereas a maximal effective dose of bosentan given on top of macitentan did not cause any additional MPAP decrease. The add-on effect of macitentan on top of bosentan in two pathological models confirms that this novel compound can achieve a superior blockade of ET receptors and provides evidence for greater maximal efficacy. Copyright © 2014. Published by Elsevier Inc.
A Single 30-s Stretch Is Sufficient to Inhibit Maximal Voluntary Strength
ERIC Educational Resources Information Center
Winchester, Jason B.; Nelson, Arnold G.; Kokkonen, Joke
2009-01-01
While it has been well established that an acute stretching program can inhibit maximal muscle performance, the amount of stretching needed to produce the deleterious response is unknown. Therefore this study examined the dose-response relationship between acute stretching and strength inhibition. Eighteen college students performed a one…
Colucci, E; Clark, A; Lang, C E; Pomeroy, V M
2017-12-01
Dose-optimisation studies as precursors to clinical trials are rare in stroke rehabilitation. To develop a rule-based, dose-finding design for stroke rehabilitation research. 3+3 rule-based, dose-finding study. Dose escalation/de-escalation was undertaken according to preset rules and a mathematical sequence (modified Fibonacci sequence). The target starting daily dose was 50 repetitions for the first cohort. Adherence was recorded by an electronic counter. At the end of the 2-week training period, the adherence record indicated dose tolerability (adherence to target dose) and the outcome measure indicated dose benefit (10% increase in motor function). The preset increment/decrease and checking rules were then applied to set the dose for the subsequent cohort. The process was repeated until preset stopping rules were met. Participants had a mean age of 68 (range 48 to 81) years, and were a mean of 70 (range 9 to 289) months post stroke with moderate upper limb paresis. A custom-built model of exercise-based training to enhance ability to open the paretic hand. Repetitions per minute of extension/flexion of paretic digits against resistance. Usability of the preset rules and whether the maximally tolerated dose was identifiable. Five cohorts of three participants were involved. Discernibly different doses were set for each subsequent cohort (i.e. 50, 100, 167, 251 and 209 repetitions/day). The maximally tolerated dose for the model training task was 209 repetitions/day. This dose-finding design is a feasible method for use in stroke rehabilitation research. Copyright © 2017 Chartered Society of Physiotherapy. All rights reserved.
FDG-PET Assessment of the Effect of Head and Neck Radiotherapy on Parotid Gland Glucose Metabolism
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roach, Michael C.; Turkington, Timothy G.; Department of Biomedical Engineering, Duke University Medical Center, Duke University, Durham, NC
Purpose: Functional imaging with [F-18]-fluorodeoxyglucose positron emission tomography (FDG-PET) provides the opportunity to define the physiology of the major salivary glands before and after radiation therapy. The goal of this retrospective study was to identify the radiation dose-response relationship of parotid gland glucose metabolism in patients with head and neck squamous cell carcinoma (HNSCC). Materials and Methods: Forty-nine adults with HNSCC were identified who had curative intent intensity-modulated radiation therapy (IMRT) and FDG-PET imaging before and after treatment. Using a graphical user interface, contours were delineated for the parotid glands on axial CT slices while all authors were blinded tomore » paired PET slices. Average and maximal standard uptake values (SUV) were measured within these anatomic regions. Changes in SUV and volume after radiation therapy were correlated with parotid gland dose-volume histograms from IMRT plans. Results: The average parotid gland volume was 30.7 mL and contracted 3.9 {+-} 1.9% with every increase of 10 Gy in mean dose (p = 0.04). However, within the first 3 months after treatment, there was a uniform reduction of 16.5% {+-} 7.3% regardless of dose. The average SUV{sub mean} of the glands was 1.63 {+-} 0.48 pretreatment and declined by 5.2% {+-} 2.5% for every increase of 10 Gy in mean dose (p = 0.04). The average SUV{sub max} was 4.07 {+-} 2.85 pretreatment and decreased in a sigmoid manner with mean dose. A threshold of 32 Gy for mean dose existed, after which SUV{sub max} declined rapidly. Conclusion: Radiation dose responses of the parotid glands can be measured by integrated CT/FDG-PET scans. Retrospective analysis showed sigmoidal declines in the maximum metabolism but linear declines in the average metabolism of the glands with dose. Future studies should correlate this decline in FDG uptake with saliva production to improve treatment planning.« less
Chen, Chong-Sheng; Doloff, Joshua C; Waxman, David J
2014-01-01
Metronomic chemotherapy using cyclophosphamide (CPA) is widely associated with antiangiogenesis; however, recent studies implicate other immune-based mechanisms, including antitumor innate immunity, which can induce major tumor regression in implanted brain tumor models. This study demonstrates the critical importance of drug schedule: CPA induced a potent antitumor innate immune response and tumor regression when administered intermittently on a 6-day repeating metronomic schedule but not with the same total exposure to activated CPA administered on an every 3-day schedule or using a daily oral regimen that serves as the basis for many clinical trials of metronomic chemotherapy. Notably, the more frequent metronomic CPA schedules abrogated the antitumor innate immune and therapeutic responses. Further, the innate immune response and antitumor activity both displayed an unusually steep dose-response curve and were not accompanied by antiangiogenesis. The strong recruitment of innate immune cells by the 6-day repeating CPA schedule was not sustained, and tumor regression was abolished, by a moderate (25%) reduction in CPA dose. Moreover, an ∼20% increase in CPA dose eliminated the partial tumor regression and weak innate immune cell recruitment seen in a subset of the every 6-day treated tumors. Thus, metronomic drug treatment must be at a sufficiently high dose but also sufficiently well spaced in time to induce strong sustained antitumor immune cell recruitment. Many current clinical metronomic chemotherapeutic protocols employ oral daily low-dose schedules that do not meet these requirements, suggesting that they may benefit from optimization designed to maximize antitumor immune responses. PMID:24563621
Grover, Anita; Benet, Leslie Z.
2013-01-01
Intermittent drug dosing intervals are usually initially guided by the terminal pharmacokinetic half life and are dependent on drug formulation. For chronic multiple dosing and for extended release dosage forms, the terminal half life often does not predict the plasma drug accumulation or fluctuation observed. We define and advance applications for the operational multiple dosing half lives for drug accumulation and fluctuation after multiple oral dosing at steady-state. Using Monte Carlo simulation, our results predict a way to maximize the operational multiple dosing half lives relative to the terminal half life by using a first-order absorption rate constant close to the terminal elimination rate constant in the design of extended release dosage forms. In this way, drugs that may be eliminated early in the development pipeline due to a relatively short half life can be formulated to be dosed at intervals three times the terminal half life, maximizing compliance, while maintaining tight plasma concentration accumulation and fluctuation ranges. We also present situations in which the operational multiple dosing half lives will be especially relevant in the determination of dosing intervals, including for drugs that follow a direct PKPD model and have a narrow therapeutic index, as the rate of concentration decrease after chronic multiple dosing (that is not the terminal half life) can be determined via simulation. These principles are illustrated with case studies on valproic acid, diazepam, and anti-hypertensives. PMID:21499748
Juzeniene, Asta; Grigalavicius, Mantas; Baturaite, Zivile; Moan, Johan
2014-11-01
Sigmoidal (S-shaped) dose-cancer incidence relationships are often observed in animal bioassays for carcinogenicity. Ultraviolet (UV) radiation is an established skin carcinogen. The aim of this study is to examine if S-shaped curves describe the relationship between solar UV doses and skin cancer incidences, and if such relationships can be used to estimate threshold levels of non-carcinogenic UV exposure, as well as maximal incidence rates. We studied the incidence rate-annual erythema-effective UV dose relationship for squamous cell carcinoma (SCC), basal cell carcinoma (BCC) and cutaneous melanoma (CM) among different Caucasian populations in Europe, Australia and New Zealand. Our analysis indicates that S-shaped associations describe the data well (P < 0.0001). The age-adjusted incidence rates for cases expected to be due to other causes than solar UV exposure (at zero UV dose) were found to be around 0.6, 9.7 and 4.0 per 100,000 for women in 1997-2007 for SCC, BCC and CM, respectively, and around 1.2, 14.3 and 2.6 per 100,000 for men. The analysis indicates that SCC, BCC and CM have maximal incidence of 361 ± 24, 1544 ± 49 and 36 ± 4 per 100,000 for women, and 592 ± 35, 2204 ± 109 and 50 ± 4 per 100,000 for men. Between 89 and 95% of the annual CM cases, around 99.8% SCC and 99.4% BCC cases are caused by solar UV exposure. The analysis did not identify any "safe" UV dose below which the risk for skin cancer was absent. Avoidance of UV radiation has a potential to reduce the incidence of skin cancer in fair-skinned population. Copyright © 2014 Elsevier GmbH. All rights reserved.
Effect of reduced agalsidase Beta dosage in fabry patients: the Australian experience.
Ghali, Joanna; Nicholls, Kathy; Denaro, Charles; Sillence, David; Chapman, Ian; Goldblatt, Jack; Thomas, Mark; Fletcher, Janice
2012-01-01
In Australia, enzyme replacement therapy (ERT) for Fabry Disease (FD), both Agalsidase alfa (Replagal, Shire HGT) and beta (Fabrazyme, Genzyme), is funded and monitored through a specific government program. Agalsidase beta supply has been rationed by Genzyme since 2009 due to manufacturing issues. Consequently, the Australian Fabry Disease Advisory Committee has treated patients on Agalsidase beta at 50% of their usual dose from mid-2009, with a further reduction to 30% for some patients from late 2009. To determine the clinical effect of Agalsidase beta dose reduction in the Australian FD patient cohort. A questionnaire assessing FD symptoms was administered to 40 patients on long-term ERT. Clinical data from The Fabry Registry for patients receiving Agalsidase alfa or beta, for at least 2 years prior to the time of enforced Agalsidase beta dose reduction, were reviewed. Disease burden and quality of life (QOL) were graded using the Disease Severity Scoring System, Mainz Severity Score Index, Brief Pain Inventory and Short Form 36 Health Survey at 2 years before dose reduction, at the time of dose reduction and at the most recent clinical review following dose reduction. Disease severity and QOL scores did not change between the ERT groups. Males on Agalsidase beta reported lower energy levels after dose reduction, while no change was reported by females on either product or by males on a stable dose of Agalsidase alfa. This study suggests that energy levels in male patients worsen after dose reduction of Agalsidase beta.
Efficacy of radiation safety glasses in interventional radiology.
van Rooijen, Bart D; de Haan, Michiel W; Das, Marco; Arnoldussen, Carsten W K P; de Graaf, R; van Zwam, Wim H; Backes, Walter H; Jeukens, Cécile R L P N
2014-10-01
This study was designed to evaluate the reduction of the eye lens dose when wearing protective eyewear in interventional radiology and to identify conditions that optimize the efficacy of radiation safety glasses. The dose reduction provided by different models of radiation safety glasses was measured on an anthropomorphic phantom head. The influence of the orientation of the phantom head on the dose reduction was studied in detail. The dose reduction in interventional radiological practice was assessed by dose measurements on radiologists wearing either leaded or no glasses or using a ceiling suspended screen. The different models of radiation safety glasses provided a dose reduction in the range of a factor of 7.9-10.0 for frontal exposure of the phantom. The dose reduction was strongly reduced when the head is turned to the side relative to the irradiated volume. The eye closest to the tube was better protected due to side shielding and eyewear curvature. In clinical practice, the mean dose reduction was a factor of 2.1. Using a ceiling suspended lead glass shield resulted in a mean dose reduction of a factor of 5.7. The efficacy of radiation protection glasses depends on the orientation of the operator's head relative to the irradiated volume. Glasses can offer good protection to the eye under clinically relevant conditions. However, the performance in clinical practice in our study was lower than expected. This is likely related to nonoptimized room geometry and training of the staff as well as measurement methodology.
Assessment of female breast dose for thoracic cone-beam CT using MOSFET dosimeters
Qiu, Bo; Liang, Jian; Xie, Weihao; Deng, Xiaowu; Qi, Zhenyu
2017-01-01
Objective: To assess the breast dose during a routine thoracic cone-beam CT (CBCT) check with the efforts to explore the possible dose reduction strategy. Materials and Methods: Metal oxide semiconductor field-effect transistor (MOSFET) dosimeters were used to measure breast surface doses during a thorax kV CBCT scan in an anthropomorphic phantom. Breast doses for different scanning protocols and breast sizes were compared. Dose reduction was attempted by using partial arc CBCT scan with bowtie filter. The impact of this dose reduction strategy on image registration accuracy was investigated. Results: The average breast surface doses were 20.02 mGy and 11.65 mGy for thoracic CBCT without filtration and with filtration, respectively. This indicates a dose reduction of 41.8% by use of bowtie filter. It was found 220° partial arc scanning significantly reduced the dose to contralateral breast (44.4% lower than ipsilateral breast), while the image registration accuracy was not compromised. Conclusions: Breast dose reduction can be achieved by using ipsilateral 220° partial arc scan with bowtie filter. This strategy also provides sufficient image quality for thorax image registration in daily patient positioning verification. PMID:28423624
Savoiu, Germaine; Drăgan, Simona; Cristescu, Carmen; Serban, Corină; Noveanu, Lavinia; Ionescu, Daniela; Nicola, T; Duicu, Oana; Răducan, Andreea; Voicu, Mirela
2009-01-01
The main changes of the plasma lipid profile in patients with endothelial dysfunction are the increased triglyceride content of the lipoprotein remnant particles, the presence of the small and dense LDL particles and the decreasing of the HDL-cholesterol level. Considering these observations, we performed "in vitro" experiments using human mammary artery rings, in order to examine the effect of the lipoprotein "remnants" on endothelium-dependent vasodilatation induced by cumulative doses (10(-9) M - 10(-4) M) of adenosine (ADP) and to study the effect on endothelial--independent vasodilatation induced by cumulative doses (10(-9) M-10(-4) M) of sodium-nitropruside (NSP), respectively. Our results showed that 1 hour pre-incubation with triglyceride--rich lipoprotein remnants diminished the endothelial-dependent vasodilator response to ADP, but it has not modified the endothelial-independent vasodilator response to NSP. Vascular response was expressed as maximal vasodilatation from the 10(-4)M phenilephrine (PE) induced pre-contraction, considered as reference. In the case of ADP, the maximal vasodilatation was ranged in 36.50% +/- 10.81% interval, comparing with the control group that presented a maximal vasodilatation of 66.15% +/- 19.41% (p < 0.005). In the case of NSP the maximal vasodilatation was ranged in 99.78% +/- 10.53% interval, comparing with the control that presented a maximal vasodilatation of 98.99% +/- 12.45% (p = 0.44). One hour co-incubation of the rings with a solution containing lipoprotein remnants (1% oxidized IDL (ox-IDL) and antioxidant factor (150 U/mL 10(-4) M Superoxid dismutase (SOD) significantly reduced the impairment of the vasodilatation response to ADP. Maximal vasodilatation of ox-IDL and SOD coincubated human mammary artery rings was 58.50% +/- 10.63% compared to the control, were the maximal vasodilatation was 66.15% +/- 19.41% (p < 0.01), but has not modified the vasodilatation response to NSP (99% +/- 0.53% vs control 98.99% +/- 12.45%, p = 0.56). The endothelial dysfunction induced by the triglyceride-rich lipoprotein "remnants", could contribute to the pathogenesis of atherosclerosis and the treatment with high doses of antioxidants could "protect" the endothelium against the pro-atherogenic action of the lipoprotein "remnants".
New insights into the mechanism and actions of growth hormone (GH) in poultry.
Vasilatos-Younken, R; Wang, X H; Zhou, Y; Day, J R; McMurtry, J P; Rosebrough, R W; Decuypere, E; Buys, N; Darras, V; Beard, J L; Tomas, F
1999-10-01
Despite well documented anabolic effects of GH in mammals, a clear demonstration of such responses in domestic poultry is lacking. Recently, comprehensive dose-response studies of GH have been conducted in broilers during late post-hatch development (8 to 9 weeks of age). GH reduced feed intake (FI) and body weight gain in a dose-dependent manner, whereas birds pair-fed to the level of voluntary FI of GH-infused birds did not differ from controls. The reduction in voluntary FI may involve centrally mediated mechanisms, as hypothalamic neuropeptide Y protein and mRNA were reduced with GH, coincident with the maximal depression in FI. Growth of breast muscle was also reduced in a dose-dependent manner. Circulating IGF-I was not enhanced by GH, despite evidence that early events in the GH signaling pathway were intact. A GH dose-dependent increase in circulating 3,3',5-triiodothyronine(T3) paralleled decreases in hepatic 5D-III monodeiodinase activity, whereas 5'D-I activity was not altered. This confirms that a marked hyperthyroid response to GH occurs in late posthatch chickens, resulting from a decrease in the degradative pathway of T3 metabolism. This secondary hyperthyroidism would account for the decreased skeletal muscle mass (52) and lack of enhanced IGF-I (53) in GH-treated birds. Based upon these studies, it is now evident that GH does in fact have significant effects in poultry, but metabolic responses may confound the anabolic potential of the hormone.
Rayan, Mona; Tawfik, Mazen; Alabd, Ali; Gamal, Amr
2011-08-01
To prospectively assess the safety and efficacy of ivabradine in patients with idiopathic dilated cardiomyopathy. We included 35 patients with idiopathic dilated cardiomyopathy with an ejection fraction (EF) <40% and heart rate >70 beats/min despite optimal medical therapy, according to the international guidelines in this prospective, non-randomized, single-arm, open-label safety study. Ivabradine was used as an add-on therapy to the maximally tolerated b-blocker in an increasing titrated dose till a target dose of 15 mg/day or resting heart rate of 60 beats/min for 3 months. During follow-up period the safety, patient tolerance and efficacy of this drug were assessed. All patients underwent 12-lead resting electrocardiography and Holter monitoring at inclusion and after 3 months. Statistical analysis was accomplished using paired t-test and Pearson correlation analysis. We found a significant reduction in the resting heart rate by a mean of 25.9 ± 9.4%, without a significant change of blood pressure. There was no prolongation of PR, QTc or QRS durations. Ventricular ectopic activity showed significant reduction (p<0.001). There was a significant correlation between the resting heart rate, NYHA and left ventricular ejection fraction (p<0.001 for both). One patient developed photopsia and decompensation was observed in another patient. Ivabradine is a safe and effective drug in reducing resting heart rate, improving NYHA functional class without undesirable effects on conduction parameters or ectopic activity.
Monzen, Satoru; Hosoda, Masahiro; Osanai, Minoru; Tokonami, Shinji
2014-01-01
Numerous radionuclides were released from the Fukushima Daiichi Nuclear Power Station (F1-NPS) in Japan following the magnitude 9.0 earthquake and tsunami on March 11, 2011. Local residents have been eager to calculate their individual radiation exposure. Thus, absorbed dose rates in the indoor and outdoor air at evacuation sites in the Fukushima Prefecture were measured using a gamma-ray measuring devices, and individual radiation exposure was calculated by assessing the radiation dose reduction efficiency (defined as the ratio of absorbed dose rate in the indoor air to the absorbed dose rate in the outdoor air) of wood, aluminum, and reinforced concrete buildings. Between March 2011 and July 2011, dose reduction efficiencies of wood, aluminum, and reinforced concrete buildings were 0.55 ± 0.04, 0.15 ± 0.02, and 0.19 ± 0.04, respectively. The reduction efficiency of wood structures was 1.4 times higher than that reported by the International Atomic Energy Agency. The efficiency of reinforced concrete was similar to previously reported values, whereas that of aluminum structures has not been previously reported. Dose reduction efficiency increased in proportion to the distance from F1-NPS at 8 of the 18 evacuation sites. Time variations did not reflect dose reduction efficiencies at evacuation sites although absorbed dose rates in the outdoor air decreased. These data suggest that dose reduction efficiency depends on structure types, levels of contamination, and evacuee behaviors at evacuation sites.
Increased Notch3 Activity Mediates pathological Changes in Structure of Cerebral arteries
Baron-Menguy, Celine; Domenga-Denier, Valérie; Ghezali, Lamia; Faraci, Frank; Joutel, Anne
2016-01-01
CADASIL, the most frequent genetic cause of stroke and vascular dementia, is caused by highly stereotyped mutations in the NOTCH3 receptor, which is predominantly expressed in vascular smooth muscle. The well-established TgNotch3R169C mouse model develops characteristic features of the human disease, with deposition of NOTCH3 and other proteins, including TIMP3 (tissue inhibitor of metalloproteinase 3), on brain vessels as well as reduced maximal dilation, and attenuated myogenic tone of cerebral arteries, but without elevated blood pressure. Increased TIMP3 levels were recently shown to be a major determinant of altered myogenic tone. In this study, we investigated the contribution of TIMP3 and Notch3 signaling to the impairment of maximal vasodilator capacity caused by the archetypal R169C mutation. Maximally dilated cerebral arteries in TgNotch3R169C mice exhibited a decrease in lumen diameter over a range of physiological pressures that occurred prior to myogenic tone deficits. This defect was not prevented by genetic reduction of TIMP3 in TgNotch3R169C mice and was not observed in mice overexpressing TIMP3. Knock-in mice with the R169C mutation (Notch3R170C/R170C) exhibited similar reductions in arterial lumen, and both TgNotch3R169C and Notch3R170C/R170C mice showed increased cerebral artery expression of Notch3 target genes. Reduced maximal vasodilation was prevented by conditional reduction of Notch activity in smooth muscle of TgNotch3R169C mice and mimicked by conditional activation of Notch3 in smooth muscle, an effect that was blood pressure-independent. We conclude that increased Notch3 activity mediates reduction in maximal dilator capacity of cerebral arteries in CADASIL and may contribute to reductions in cerebral blood flow. PMID:27821617
Increased Notch3 Activity Mediates Pathological Changes in Structure of Cerebral Arteries.
Baron-Menguy, Celine; Domenga-Denier, Valérie; Ghezali, Lamia; Faraci, Frank M; Joutel, Anne
2017-01-01
CADASIL (Cerebral Autosomal Dominant Arteriopathy With Subcortical Infarcts and Leukoencephalopathy), the most frequent genetic cause of stroke and vascular dementia, is caused by highly stereotyped mutations in the NOTCH3 receptor, which is predominantly expressed in vascular smooth muscle. The well-established TgNotch3 R169C mouse model develops characteristic features of the human disease, with deposition of NOTCH3 and other proteins, including TIMP3 (tissue inhibitor of metalloproteinase 3), on brain vessels, as well as reduced maximal dilation, and attenuated myogenic tone of cerebral arteries, but without elevated blood pressure. Increased TIMP3 levels were recently shown to be a major determinant of altered myogenic tone. In this study, we investigated the contribution of TIMP3 and Notch3 signaling to the impairment of maximal vasodilator capacity caused by the archetypal R169C mutation. Maximally dilated cerebral arteries in TgNotch3 R169C mice exhibited a decrease in lumen diameter over a range of physiological pressures that occurred before myogenic tone deficits. This defect was not prevented by genetic reduction of TIMP3 in TgNotch3 R169C mice and was not observed in mice overexpressing TIMP3. Knock-in mice with the R169C mutation (Notch3 R170C/R170C ) exhibited similar reductions in arterial lumen, and both TgNotch3 R169C and Notch3 R170C/R170C mice showed increased cerebral artery expression of Notch3 target genes. Reduced maximal vasodilation was prevented by conditional reduction of Notch activity in smooth muscle of TgNotch3 R169C mice and mimicked by conditional activation of Notch3 in smooth muscle, an effect that was blood pressure-independent. We conclude that increased Notch3 activity mediates reduction in maximal dilator capacity of cerebral arteries in CADASIL and may contribute to reductions in cerebral blood flow. © 2016 American Heart Association, Inc.
Goren, AD; Prins, RD; Dauer, LT; Quinn, B; Al-Najjar, A; Faber, RD; Patchell, G; Branets, I; Colosi, DC
2013-01-01
Objectives: This study aims to demonstrate the effectiveness of leaded glasses in reducing the lens of eye dose and of lead thyroid collars in reducing the dose to the thyroid gland of an adult female from dental cone beam CT (CBCT). The effect of collimation on the radiation dose in head organs is also examined. Methods: Dose measurements were conducted by placing optically stimulated luminescent dosemeters in an anthropomorphic female phantom. Eye lens dose was measured by placing a dosemeter on the anterior surface of the phantom eye location. All exposures were performed on one commercially available dental CBCT machine, using selected collimation and exposure techniques. Each scan technique was performed without any lead shielding and then repeated with lead shielding in place. To calculate the percent reduction from lead shielding, the dose measured with lead shielding was divided by the dose measured without lead shielding. The percent reduction from collimation was calculated by comparing the dose measured with collimation to the dose measured without collimation. Results: The dose to the internal eye for one of the scans without leaded glasses or thyroid shield was 0.450 cGy and with glasses and thyroid shield was 0.116 cGy (a 74% reduction). The reduction to the lens of the eye was from 0.396 cGy to 0.153 cGy (a 61% reduction). Without glasses or thyroid shield, the thyroid dose was 0.158 cGy; and when both glasses and shield were used, the thyroid dose was reduced to 0.091 cGy (a 42% reduction). Conclusions: Collimation alone reduced the dose to the brain by up to 91%, with a similar reduction in other organs. Based on these data, leaded glasses, thyroid collars and collimation minimize the dose to organs outside the field of view. PMID:23412460
Jarrahian, Courtney; Rein-Weston, Annie; Saxon, Gene; Creelman, Ben; Kachmarik, Greg; Anand, Abhijeet; Zehrung, Darin
2017-03-27
Intradermal delivery of a fractional dose of inactivated poliovirus vaccine (IPV) offers potential benefits compared to intramuscular (IM) delivery, including possible cost reductions and easing of IPV supply shortages. Objectives of this study were to assess intradermal delivery devices for dead space, wastage generated by the filling process, dose accuracy, and total number of doses that can be delivered per vial. Devices tested included syringes with staked (fixed) needles (autodisable syringes and syringes used with intradermal adapters), a luer-slip needle and syringe, a mini-needle syringe, a hollow microneedle device, and disposable-syringe jet injectors with their associated filling adapters. Each device was used to withdraw 0.1-mL fractional doses from single-dose IM glass vials which were then ejected into a beaker. Both vial and device were weighed before and after filling and again after expulsion of liquid to record change in volume at each stage of the process. Data were used to calculate the number of doses that could potentially be obtained from multidose vials. Results show wide variability in dead space, dose accuracy, overall wastage, and total number of doses that can be obtained per vial among intradermal delivery devices. Syringes with staked needles had relatively low dead space and low overall wastage, and could achieve a greater number of doses per vial compared to syringes with a detachable luer-slip needle. Of the disposable-syringe jet injectors tested, one was comparable to syringes with staked needles. If intradermal delivery of IPV is introduced, selection of an intradermal delivery device can have a substantial impact on vaccine wasted during administration, and thus on the required quantity of vaccine that needs to be purchased. An ideal intradermal delivery device should be not only safe, reliable, accurate, and acceptable to users and vaccine recipients, but should also have low dead space, high dose accuracy, and low overall wastage to maximize the potential number of doses that can be withdrawn and delivered. Copyright © 2017 PATH. Published by Elsevier Ltd.. All rights reserved.
Chatterson, Leslie C; Leswick, David A; Fladeland, Derek A; Hunt, Megan M; Webster, Stephen; Lim, Hyun
2014-07-01
Custom bismuth-antimony shields were previously shown to reduce fetal dose by 53% on an 8DR (detector row) CT scanner without dynamic adaptive section collimation (DASC), automatic tube current modulation (ATCM) or adaptive statistical iterative reconstruction (ASiR). The purpose of this study is to compare the effective maternal and average fetal organ dose reduction both with and without bismuth-antimony shields on a 64DR CT scanner using DASC, ATCM and ASiR during maternal CTPA. A phantom with gravid prosthesis and a bismuth-antimony shield were used. Thermoluminescent dosimeters (TLDs) measured fetal radiation dose. The average fetal organ dose and effective maternal dose were determined using 100 kVp, scanning from the lung apices to the diaphragm utilizing DASC, ATCM and ASiR on a 64DR CT scanner with and without shielding in the first and third trimester. Isolated assessment of DASC was done via comparing a new 8DR scan without DASC to a similar scan on the 64DR with DASC. Average third trimester unshielded fetal dose was reduced from 0.22 mGy ± 0.02 on the 8DR to 0.13 mGy ± 0.03 with the conservative 64DR protocol that included 30% ASiR, DASC and ATCM (42% reduction, P<0.01). Use of a shield further reduced average third trimester fetal dose to 0.04 mGy ± 0.01 (69% reduction, P<0.01). The average fetal organ dose reduction attributable to DASC alone was modest (6% reduction from 0.17 mGy ± 0.02 to 0.16 mGy ± 0.02, P=0.014). First trimester fetal organ dose on the 8DR protocol was 0.07 mGy ± 0.03. This was reduced to 0.05 mGy ± 0.03 on the 64DR protocol without shielding (30% reduction, P=0.009). Shields further reduced this dose to below accurately detectable levels. Effective maternal dose was reduced from 4.0 mSv on the 8DR to 2.5 mSv on the 64DR scanner using the conservative protocol (38% dose reduction). ASiR, ATCM and DASC combined significantly reduce effective maternal and fetal organ dose during CTPA. Shields continue to be an effective means of fetal dose reduction. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Denis-Bacelar, Ana M.; Chittenden, Sarah J.; Murray, Iain; Divoli, Antigoni; McCready, V. Ralph; Dearnaley, David P.; O'Sullivan, Joe M.; Johnson, Bernadette; Flux, Glenn D.
2017-04-01
Skeletal tumour burden is a biomarker of prognosis and survival in cancer patients. This study proposes a novel method based on the linear quadratic model to predict the reduction in metastatic tumour burden as a function of the absorbed doses delivered from molecular radiotherapy treatments. The range of absorbed doses necessary to eradicate all the bone lesions and to reduce the metastatic burden was investigated in a cohort of 22 patients with bone metastases from castration-resistant prostate cancer. A metastatic burden reduction curve was generated for each patient, which predicts the reduction in metastatic burden as a function of the patient mean absorbed dose, defined as the mean of all the lesion absorbed doses in any given patient. In the patient cohort studied, the median of the patient mean absorbed dose predicted to reduce the metastatic burden by 50% was 89 Gy (interquartile range: 83-105 Gy), whilst a median of 183 Gy (interquartile range: 107-247 Gy) was found necessary to eradicate all metastases in a given patient. The absorbed dose required to eradicate all the lesions was strongly correlated with the variability of the absorbed doses delivered to multiple lesions in a given patient (r = 0.98, P < 0.0001). The metastatic burden reduction curves showed a potential large reduction in metastatic burden for a small increase in absorbed dose in 91% of patients. The results indicate the range of absorbed doses required to potentially obtain a significant survival benefit. The metastatic burden reduction method provides a simple tool that could be used in routine clinical practice for patient selection and to indicate the required administered activity to achieve a predicted patient mean absorbed dose and reduction in metastatic tumour burden.
State of the Science: Biologically Based Modeling in Risk Assessment [Editorial
The health risk assessment from exposure to a particular agent is preferred when the assessment is based on a relevant measure of internal dose (e.g., maximal concentration of an active metabolite in target tissue) rather than simply the administered dose or exposure concentratio...
NASA Astrophysics Data System (ADS)
Yan, Hao; Cervino, Laura; Jia, Xun; Jiang, Steve B.
2012-04-01
While compressed sensing (CS)-based algorithms have been developed for the low-dose cone beam CT (CBCT) reconstruction, a clear understanding of the relationship between the image quality and imaging dose at low-dose levels is needed. In this paper, we qualitatively investigate this subject in a comprehensive manner with extensive experimental and simulation studies. The basic idea is to plot both the image quality and imaging dose together as functions of the number of projections and mAs per projection over the whole clinically relevant range. On this basis, a clear understanding of the tradeoff between the image quality and imaging dose can be achieved and optimal low-dose CBCT scan protocols can be developed to maximize the dose reduction while minimizing the image quality loss for various imaging tasks in image-guided radiation therapy (IGRT). Main findings of this work include (1) under the CS-based reconstruction framework, image quality has little degradation over a large range of dose variation. Image quality degradation becomes evident when the imaging dose (approximated with the x-ray tube load) is decreased below 100 total mAs. An imaging dose lower than 40 total mAs leads to a dramatic image degradation, and thus should be used cautiously. Optimal low-dose CBCT scan protocols likely fall in the dose range of 40-100 total mAs, depending on the specific IGRT applications. (2) Among different scan protocols at a constant low-dose level, the super sparse-view reconstruction with the projection number less than 50 is the most challenging case, even with strong regularization. Better image quality can be acquired with low mAs protocols. (3) The optimal scan protocol is the combination of a medium number of projections and a medium level of mAs/view. This is more evident when the dose is around 72.8 total mAs or below and when the ROI is a low-contrast or high-resolution object. Based on our results, the optimal number of projections is around 90 to 120. (4) The clinically acceptable lowest imaging dose level is task dependent. In our study, 72.8 mAs is a safe dose level for visualizing low-contrast objects, while 12.2 total mAs is sufficient for detecting high-contrast objects of diameter greater than 3 mm.
Influence of Lumber Volume Maximization on Value in Sawing Hardwood Sawlogs
Philip H. Steele; Francis G. Wagner; Lalit Kumar; Philip A. Araman
1992-01-01
Research based on applying volume-maximizing sawing solutions to idealized hardwood log forms has shown that average lumber yield can be increased by 6 percent. It is possible, however, that a lumber volume-maximizing solution may result in a decrease in lumber grade and a net reduction in total value of sawn lumber. The objective of this study was to determine the...
Generalizable Class Solutions for Treatment Planning of Spinal Stereotactic Body Radiation Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weksberg, David C.; Palmer, Matthew B.; Vu, Khoi N.
2012-11-01
Purpose: Spinal stereotactic body radiation therapy (SBRT) continues to emerge as an effective therapeutic approach to spinal metastases; however, treatment planning and delivery remain resource intensive at many centers, which may hamper efficient implementation in clinical practice. We sought to develop a generalizable class solution approach for spinal SBRT treatment planning that would allow confidence that a given plan provides optimal target coverage, reduce integral dose, and maximize planning efficiency. Methods and Materials: We examined 91 patients treated with spinal SBRT at our institution. Treatment plans were categorized by lesion location, clinical target volume (CTV) configuration, and dose fractionation scheme,more » and then analyzed to determine the technically achievable dose gradient. A radial cord expansion was subtracted from the CTV to yield a planning CTV (pCTV) construct for plan evaluation. We reviewed the treatment plans with respect to target coverage, dose gradient, integral dose, conformality, and maximum cord dose to select the best plans and develop a set of class solutions. Results: The class solution technique generated plans that maintained target coverage and improved conformality (1.2-fold increase in the 95% van't Riet Conformation Number describing the conformality of a reference dose to the target) while reducing normal tissue integral dose (1.3-fold decrease in the volume receiving 4 Gy (V{sub 4Gy}) and machine output (19% monitor unit (MU) reduction). In trials of planning efficiency, the class solution technique reduced treatment planning time by 30% to 60% and MUs required by {approx}20%: an effect independent of prior planning experience. Conclusions: We have developed a set of class solutions for spinal SBRT that incorporate a pCTV metric for plan evaluation while yielding dosimetrically superior treatment plans with increased planning efficiency. Our technique thus allows for efficient, reproducible, and high-quality spinal SBRT treatment planning.« less
Parallel State Space Construction for a Model Checking Based on Maximality Semantics
NASA Astrophysics Data System (ADS)
El Abidine Bouneb, Zine; Saīdouni, Djamel Eddine
2009-03-01
The main limiting factor of the model checker integrated in the concurrency verification environment FOCOVE [1, 2], which use the maximality based labeled transition system (noted MLTS) as a true concurrency model[3, 4], is currently the amount of available physical memory. Many techniques have been developed to reduce the size of a state space. An interesting technique among them is the alpha equivalence reduction. Distributed memory execution environment offers yet another choice. The main contribution of the paper is to show that the parallel state space construction algorithm proposed in [5], which is based on interleaving semantics using LTS as semantic model, may be adapted easily to the distributed implementation of the alpha equivalence reduction for the maximality based labeled transition systems.
An automated system for reduction of the firm's employees under maximal overall efficiency
NASA Astrophysics Data System (ADS)
Yonchev, Yoncho; Nikolov, Simeon; Baeva, Silvia
2012-11-01
Achieving maximal overall efficiency is a priority in all companies. This problem is formulated as a knap-sack problem and afterwards as a linear assignment problem. An automated system is created for solving of this problem.
Favazza, Christopher P; Ferrero, Andrea; Yu, Lifeng; Leng, Shuai; McMillan, Kyle L; McCollough, Cynthia H
2017-07-01
The use of iterative reconstruction (IR) algorithms in CT generally decreases image noise and enables dose reduction. However, the amount of dose reduction possible using IR without sacrificing diagnostic performance is difficult to assess with conventional image quality metrics. Through this investigation, achievable dose reduction using a commercially available IR algorithm without loss of low contrast spatial resolution was determined with a channelized Hotelling observer (CHO) model and used to optimize a clinical abdomen/pelvis exam protocol. A phantom containing 21 low contrast disks-three different contrast levels and seven different diameters-was imaged at different dose levels. Images were created with filtered backprojection (FBP) and IR. The CHO was tasked with detecting the low contrast disks. CHO performance indicated dose could be reduced by 22% to 25% without compromising low contrast detectability (as compared to full-dose FBP images) whereas 50% or more dose reduction significantly reduced detection performance. Importantly, default settings for the scanner and protocol investigated reduced dose by upward of 75%. Subsequently, CHO-based protocol changes to the default protocol yielded images of higher quality and doses more consistent with values from a larger, dose-optimized scanner fleet. CHO assessment provided objective data to successfully optimize a clinical CT acquisition protocol.
Kakkar, Chandan; Sripathi, Smiti; Parakh, Anushri; Shrivastav, Rajendra
2016-01-01
Introduction Urolithiasis is one of the major, recurring problem in young individuals and CT being the commonest diagnostic modality used. In order to reduce the radiation dose to the patient who are young and as stone formation is a recurring process; one of the simplest way would be, low dose CT along with tube current modulation. Aim Aim of this study was to compare the sensitivity and specificity of low dose (70mAs) with standard dose (250mAs) protocol in detecting urolithiasis and to define the tube current and mean effective patient dose by these protocols. Materials and Methods A prospective study was conducted in 200 patients over a period of 2 years with acute flank pain presentation. CT was performed in 100 cases with standard dose and another 100 with low dose protocol using tube current modulation. Sensitivity and specificity for calculus detection, percentage reduction of dose and tube current with low dose protocol was calculated. Results Urolithiasis was detected in 138 patients, 67 were examined by high dose and 71 were by low dose protocol. Sensitivity and Specificity of low dose protocol was 97.1% and 96.4% with similar results found in high BMI patients. Tube current modulation resulted in reduction of effective tube current by 12.17%. The mean effective patient dose for standard dose was 10.33 mSv whereas 2.92 mSv for low dose with 51.13–53.8% reduction in low dose protocol. Conclusion The study has reinforced that low-dose CT with tube current modulation is appropriate for diagnosis of urolithiasis with significant reduction in tube current and patient effective dose. PMID:27437322
Koteshwar, Prakashini; Kakkar, Chandan; Sripathi, Smiti; Parakh, Anushri; Shrivastav, Rajendra
2016-05-01
Urolithiasis is one of the major, recurring problem in young individuals and CT being the commonest diagnostic modality used. In order to reduce the radiation dose to the patient who are young and as stone formation is a recurring process; one of the simplest way would be, low dose CT along with tube current modulation. Aim of this study was to compare the sensitivity and specificity of low dose (70mAs) with standard dose (250mAs) protocol in detecting urolithiasis and to define the tube current and mean effective patient dose by these protocols. A prospective study was conducted in 200 patients over a period of 2 years with acute flank pain presentation. CT was performed in 100 cases with standard dose and another 100 with low dose protocol using tube current modulation. Sensitivity and specificity for calculus detection, percentage reduction of dose and tube current with low dose protocol was calculated. Urolithiasis was detected in 138 patients, 67 were examined by high dose and 71 were by low dose protocol. Sensitivity and Specificity of low dose protocol was 97.1% and 96.4% with similar results found in high BMI patients. Tube current modulation resulted in reduction of effective tube current by 12.17%. The mean effective patient dose for standard dose was 10.33 mSv whereas 2.92 mSv for low dose with 51.13-53.8% reduction in low dose protocol. The study has reinforced that low-dose CT with tube current modulation is appropriate for diagnosis of urolithiasis with significant reduction in tube current and patient effective dose.
Joshi, Anuja; Gislason-Lee, Amber J; Keeble, Claire; Sivananthan, Uduvil M
2017-01-01
Objective: The aim of this research was to quantify the reduction in radiation dose facilitated by image processing alone for percutaneous coronary intervention (PCI) patient angiograms, without reducing the perceived image quality required to confidently make a diagnosis. Methods: Incremental amounts of image noise were added to five PCI angiograms, simulating the angiogram as having been acquired at corresponding lower dose levels (10–89% dose reduction). 16 observers with relevant experience scored the image quality of these angiograms in 3 states—with no image processing and with 2 different modern image processing algorithms applied. These algorithms are used on state-of-the-art and previous generation cardiac interventional X-ray systems. Ordinal regression allowing for random effects and the delta method were used to quantify the dose reduction possible by the processing algorithms, for equivalent image quality scores. Results: Observers rated the quality of the images processed with the state-of-the-art and previous generation image processing with a 24.9% and 15.6% dose reduction, respectively, as equivalent in quality to the unenhanced images. The dose reduction facilitated by the state-of-the-art image processing relative to previous generation processing was 10.3%. Conclusion: Results demonstrate that statistically significant dose reduction can be facilitated with no loss in perceived image quality using modern image enhancement; the most recent processing algorithm was more effective in preserving image quality at lower doses. Advances in knowledge: Image enhancement was shown to maintain perceived image quality in coronary angiography at a reduced level of radiation dose using computer software to produce synthetic images from real angiograms simulating a reduction in dose. PMID:28124572
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brady, S; Shulkin, B
Purpose: To develop ultra-low dose computed tomography (CT) attenuation correction (CTAC) acquisition protocols for pediatric positron emission tomography CT (PET CT). Methods: A GE Discovery 690 PET CT hybrid scanner was used to investigate the change to quantitative PET and CT measurements when operated at ultra-low doses (10–35 mAs). CT quantitation: noise, low-contrast resolution, and CT numbers for eleven tissue substitutes were analyzed in-phantom. CT quantitation was analyzed to a reduction of 90% CTDIvol (0.39/3.64; mGy) radiation dose from baseline. To minimize noise infiltration, 100% adaptive statistical iterative reconstruction (ASiR) was used for CT reconstruction. PET images were reconstructed withmore » the lower-dose CTAC iterations and analyzed for: maximum body weight standardized uptake value (SUVbw) of various diameter targets (range 8–37 mm), background uniformity, and spatial resolution. Radiation organ dose, as derived from patient exam size specific dose estimate (SSDE), was converted to effective dose using the standard ICRP report 103 method. Effective dose and CTAC noise magnitude were compared for 140 patient examinations (76 post-ASiR implementation) to determine relative patient population dose reduction and noise control. Results: CT numbers were constant to within 10% from the non-dose reduced CTAC image down to 90% dose reduction. No change in SUVbw, background percent uniformity, or spatial resolution for PET images reconstructed with CTAC protocols reconstructed with ASiR and down to 90% dose reduction. Patient population effective dose analysis demonstrated relative CTAC dose reductions between 62%–86% (3.2/8.3−0.9/6.2; mSv). Noise magnitude in dose-reduced patient images increased but was not statistically different from pre dose-reduced patient images. Conclusion: Using ASiR allowed for aggressive reduction in CTAC dose with no change in PET reconstructed images while maintaining sufficient image quality for co-localization of hybrid CT anatomy and PET radioisotope uptake.« less
Dose and risk in diagnostic radiology: How big How little Lecture Number 16
DOE Office of Scientific and Technical Information (OSTI.GOV)
Webster, E.W.
1992-01-01
This lecture is divided into two parts: dose and risk. The dose segment is technical and noncontroversial since it deals with straightforward measurements or calculations which do not depend on unproven hypotheses. Some conflicting contributions of low dose epidemiological studies to the appraisal of risk are briefly presented. Attention is focused on the following: dose reduction in radiography; dose reduction in fluoroscopy; limitations of dose reduction; estimated radiation risks for diagnostic radiology examinations; excess breast cancer following X-ray examinations for scoliosis; dose-response relation for human mammary cancer; lung cancer from protracted X-irradiation; leukemia and diagnostic X-ray exposure; and thyroid cancermore » after diagnostic dose of I-131.« less
Roth, Eli M; Moriarty, Patrick M; Bergeron, Jean; Langslet, Gisle; Manvelian, Garen; Zhao, Jian; Baccara-Dinet, Marie T; Rader, Daniel J
2016-11-01
In previous phase III studies, the PCSK9 monoclonal antibody alirocumab was administered at doses of 75 or 150 mg every 2 weeks (Q2W). CHOICE I (NCT01926782) evaluated 300 mg every 4 weeks (Q4W) in patients on either maximally tolerated statin or no statin, both ± other lipid-lowering therapies. CHOICE I included patients with hypercholesterolemia at moderate-to-very-high cardiovascular risk. Patients were randomized to alirocumab 300 mg Q4W, 75 mg Q2W (calibrator arm), or placebo for 48 weeks, with dose adjustment for either alirocumab arm to 150 mg Q2W at Week (W) 12 if at W8 LDL-C levels were >70/100 mg/dL (1.8/2.6 mmol/L) depending on cardiovascular risk or LDL-C reduction was <30% from baseline. Co-primary endpoints were percent LDL-C change from baseline to W24, and to time-averaged LDL-C over W21-24. Approximately two-thirds of randomized patients were receiving statins. At W12, 14.7% (no statin) and 19.3% (statin) of patients receiving alirocumab 300 mg Q4W required dose adjustment. At W24, significant LDL-C reductions from baseline were observed with alirocumab 300 mg Q4W: mean differences were -52.7% (no statin; placebo: -0.3%) and -58.8% (statin; placebo: -0.1%). Average LDL-C reductions from baseline to W21-24 were also significantly greater with alirocumab 300 mg Q4W vs. placebo in patients not receiving (-56.9% vs. -1.6%) and receiving statin (-65.8% vs. -0.8%). Treatment-emergent adverse event rates ranged from 61.1 to 75.0% (placebo) and 71.5 to 78.1% (alirocumab 300 mg Q4W). Alirocumab 300 mg Q4W is a viable additional treatment option in patients requiring LDL-C-lowering. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
van Herwaarden, Noortje; van der Maas, Aatke; Minten, Michiel J M; van den Hoogen, Frank H J; Kievit, Wietske; van Vollenhoven, Ronald F; Bijlsma, Johannes W J; van den Bemt, Bart J F; den Broeder, Alfons A
2015-04-09
To evaluate whether a disease activity guided strategy of dose reduction of two tumour necrosis factor (TNF) inhibitors, adalimumab or etanercept, is non-inferior in maintaining disease control in patients with rheumatoid arthritis compared with usual care. Randomised controlled, open label, non-inferiority strategy trial. Two rheumatology outpatient clinics in the Netherlands, from December 2011 to May 2014. 180 patients with rheumatoid arthritis and low disease activity using adalimumab or etanercept; 121 allocated to the dose reduction strategy, 59 to usual care. Disease activity guided dose reduction (advice to stepwise increase the injection interval every three months, until flare of disease activity or discontinuation) or usual care (no dose reduction advice). Flare was defined as increase in DAS28-CRP (a composite score measuring disease activity) greater than 1.2, or increase greater than 0.6 and current score of at least 3.2. In the case of flare, TNF inhibitor use was restarted or escalated. Difference in proportions of patients with major flare (DAS28-CRP based flare longer than three months) between the two groups at 18 months, compared against a non-inferiority margin of 20%. Secondary outcomes included TNF inhibitor use at study end, functioning, quality of life, radiographic progression, and adverse events. Dose reduction of adalimumab or etanercept was non-inferior to usual care (proportion of patients with major flare at 18 months, 12% v 10%; difference 2%, 95% confidence interval -12% to 12%). In the dose reduction group, TNF inhibitor use could successfully be stopped in 20% (95% confidence interval 13% to 28%), the injection interval successfully increased in 43% (34% to 53%), but no dose reduction was possible in 37% (28% to 46%). Functional status, quality of life, relevant radiographic progression, and adverse events did not differ between the groups, although short lived flares (73% v 27%) and minimal radiographic progression (32% v 15%) were more frequent in dose reduction than usual care. A disease activity guided, dose reduction strategy of adalimumab or etanercept to treat rheumatoid arthritis is non-inferior to usual care with regard to major flaring, while resulting in the successful dose reduction or stopping in two thirds of patients.Trial registration Dutch trial register (www.trialregister.nl), NTR 3216. © van Herwaarden et al 2015.
A dose ranging study of ibuprofen suspension as an antipyretic.
Marriott, S C; Stephenson, T J; Hull, D; Pownall, R; Smith, C M; Butler, A
1991-01-01
A double blind trial was conducted to determine the dose of ibuprofen suspension, which is effective in reducing the body temperature. The principal measure of efficacy was a reduction in axillary temperature of 1 degree C or more three hours after dosing. A second objective of the trial was to compare the incidence and severity of side effects and the palatability of a range of ibuprofen doses. Ninety three children were included in the analysis. All four doses of ibuprofen studied (0.625 mg/kg-5 mg/kg) were associated with temperature reduction and only the lowest dose failed to satisfy the principal measure of efficacy. The influence of dose on the magnitude of the body temperature reduction was significant and the 5 mg/kg dose achieved the largest mean reduction in body temperature (2 degrees C). The tolerability and palatability of all doses studied were excellent. These findings suggest that ibuprofen is a good alternative to paracetamol as an antipyretic. PMID:1929509
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, J; Chung, J
2015-06-15
Purpose: To verify delivered doses on the implanted cardiac pacemaker, predicted doses with and without dose reduction method were verified using the MOSFET detectors in terms of beam delivery and dose calculation techniques in intensity-modulated radiation therapy (IMRT). Methods: The pacemaker doses for a patient with a tongue cancer were predicted according to the beam delivery methods [step-and-shoot (SS) and sliding window (SW)], intensity levels for dose optimization, and dose calculation algorithms. Dosimetric effects on the pacemaker were calculated three dose engines: pencil-beam convolution (PBC), analytical anisotropic algorithm (AAA), and Acuros-XB. A lead shield of 2 mm thickness was designedmore » for minimizing irradiated doses to the pacemaker. Dose variations affected by the heterogeneous material properties of the pacemaker and effectiveness of the lead shield were predicted by the Acuros-XB. Dose prediction accuracy and the feasibility of the dose reduction strategy were verified based on the measured skin doses right above the pacemaker using mosfet detectors during the radiation treatment. Results: The Acuros-XB showed underestimated skin doses and overestimated doses by the lead-shield effect, even though the lower dose disagreement was observed. It led to improved dose prediction with higher intensity level of dose optimization in IMRT. The dedicated tertiary lead sheet effectively achieved reduction of pacemaker dose up to 60%. Conclusion: The current SS technique could deliver lower scattered doses than recommendation criteria, however, use of the lead sheet contributed to reduce scattered doses.Thin lead plate can be a useful tertiary shielder and it could not acuse malfunction or electrical damage of the implanted pacemaker in IMRT. It is required to estimate more accurate scattered doses of the patient with medical device to design proper dose reduction strategy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brady, Samuel L., E-mail: samuel.brady@stjude.org; Shulkin, Barry L.
2015-02-15
Purpose: To develop ultralow dose computed tomography (CT) attenuation correction (CTAC) acquisition protocols for pediatric positron emission tomography CT (PET CT). Methods: A GE Discovery 690 PET CT hybrid scanner was used to investigate the change to quantitative PET and CT measurements when operated at ultralow doses (10–35 mA s). CT quantitation: noise, low-contrast resolution, and CT numbers for 11 tissue substitutes were analyzed in-phantom. CT quantitation was analyzed to a reduction of 90% volume computed tomography dose index (0.39/3.64; mGy) from baseline. To minimize noise infiltration, 100% adaptive statistical iterative reconstruction (ASiR) was used for CT reconstruction. PET imagesmore » were reconstructed with the lower-dose CTAC iterations and analyzed for: maximum body weight standardized uptake value (SUV{sub bw}) of various diameter targets (range 8–37 mm), background uniformity, and spatial resolution. Radiation dose and CTAC noise magnitude were compared for 140 patient examinations (76 post-ASiR implementation) to determine relative dose reduction and noise control. Results: CT numbers were constant to within 10% from the nondose reduced CTAC image for 90% dose reduction. No change in SUV{sub bw}, background percent uniformity, or spatial resolution for PET images reconstructed with CTAC protocols was found down to 90% dose reduction. Patient population effective dose analysis demonstrated relative CTAC dose reductions between 62% and 86% (3.2/8.3–0.9/6.2). Noise magnitude in dose-reduced patient images increased but was not statistically different from predose-reduced patient images. Conclusions: Using ASiR allowed for aggressive reduction in CT dose with no change in PET reconstructed images while maintaining sufficient image quality for colocalization of hybrid CT anatomy and PET radioisotope uptake.« less
NASA Astrophysics Data System (ADS)
Stützer, K.; Bert, C.; Enghardt, W.; Helmbrecht, S.; Parodi, K.; Priegnitz, M.; Saito, N.; Fiedler, F.
2013-08-01
In-beam positron emission tomography (PET) has been proven to be a reliable technique in ion beam radiotherapy for the in situ and non-invasive evaluation of the correct dose deposition in static tumour entities. In the presence of intra-fractional target motion an appropriate time-resolved (four-dimensional, 4D) reconstruction algorithm has to be used to avoid reconstructed activity distributions suffering from motion-related blurring artefacts and to allow for a dedicated dose monitoring. Four-dimensional reconstruction algorithms from diagnostic PET imaging that can properly handle the typically low counting statistics of in-beam PET data have been adapted and optimized for the characteristics of the double-head PET scanner BASTEI installed at GSI Helmholtzzentrum Darmstadt, Germany (GSI). Systematic investigations with moving radioactive sources demonstrate the more effective reduction of motion artefacts by applying a 4D maximum likelihood expectation maximization (MLEM) algorithm instead of the retrospective co-registration of phasewise reconstructed quasi-static activity distributions. Further 4D MLEM results are presented from in-beam PET measurements of irradiated moving phantoms which verify the accessibility of relevant parameters for the dose monitoring of intra-fractionally moving targets. From in-beam PET listmode data sets acquired together with a motion surrogate signal, valuable images can be generated by the 4D MLEM reconstruction for different motion patterns and motion-compensated beam delivery techniques.
Zazueta-Beltrán, Liliana; Medina-Aymerich, Lorena; Estela Díaz-Triste, Nadia; Chávez-Piña, Aracely Evangelina; Castañeda-Hernández, Gilberto; Cruz-Antonio, Leticia
2017-03-01
To determine the role of a pharmacokinetic interaction in the protective effect of curcumin against the gastric damage induced by indomethacin administration as such or as its prodrug acemetacin. Wistar rats orally received single dose of indomethacin (30 mg/kg) with and without curcumin (30 mg/kg); gastric injury was evaluated by determining the total damaged area. Additional groups of rats received an oral single dose of indomethacin (30 mg/kg) or its prodrug acemetacin (34.86 mg/kg) in the presence or absence of curcumin (30 mg/kg). Indomethacin and acemetacin concentrations in plasma from blood draws were determined by high-performance liquid chromatography.Plasma concentration-against-time curves were constructed, and bioavailability parameters, maximal concentration (C max ) and area under the curve to the last sampling time (AUC 0-t ) were estimated. Concomitant administration of indomethacin and curcumin resulted in a significantly reduced gastric damage compared to indomethacin alone. However, co-administration of curcumin did not produce any significant alteration in the bioavailability parameters of indomethacin and acemetacin after administration of either the active compound or the prodrug. Curcumin exhibits a protective effect against indomethacin-induced gastric damage, but does not produce a reduction of the bioavailability of this nonsteroidal anti-inflammatory drug, indomethacin. Data thus suggest that a pharmacokinetic mechanism of action is not involved in curcumin gastroprotection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anscher, Mitchell S.; Garst, Jennifer; Marks, Lawrence B.
2006-10-01
Purpose: Thalidomide has broad anticytokine properties, which might protect normal tissues in patients undergoing chemoradiotherapy. The purpose of this study was to determine the maximal tolerated dose of thalidomide when used in combination with vinorelbine plus thoracic radiotherapy. Methods and Materials: Eligible patients had inoperable Stage III non-small-cell lung cancer, a Karnofsky Performance Status {>=}70, and life expectancy {>=}6 months. Patients underwent pretreatment evaluation of lung function. Radiotherapy consisted of 66 Gy in 6.5 weeks. Vinorelbine was administered i.v. (5 mg/m{sup 2}) 3 times per week just before radiotherapy. Thalidomide was begun at 50 mg, p.o., on day 1 ofmore » chemoradiotherapy and continued once daily for 6 months. Side effects were scored using National Cancer Institute Common Toxicity Criteria. Results: Ten patients were enrolled. Of the first 6 patients, 2 developed major thrombotic events that were believed to be possibly related to thalidomide. The study was suspended and modified to require prophylactic anticoagulation. Of the last 4 patients, 2 developed dose-limiting toxicity attributable to thalidomide; both patients required a dose reduction of thalidomide to <50 mg/day. Because the drug is not available in an oral product providing <50 mg/day, the study was closed. Conclusions: The combination of thalidomide concurrently with thoracic radiotherapy and vinorelbine resulted in excessive toxicity.« less
Hexamethonium attenuates sympathetic activity and blood pressure in spontaneously hypertensive rats.
Li, Peng; Gong, Jue-Xiao; Sun, Wei; Zhou, Bin; Kong, Xiang-Qing
2015-11-01
Sympathetic activity is enhanced in heart failure and hypertensive rats. The aims of the current study were: i) To investigate the association between renal sympathetic nerve activity (RSNA) and mean arterial pressure (MAP) in response to intravenous injection of the ganglionic blocker hexamethonium; and ii) to determine whether normal Wistar rats and spontaneously hypertensive rats (SHRs) differ in their response to hexamethonium. RSNA and MAP were recorded in anaesthetized rats. Intravenous injection of four doses of hexamethonium significantly reduced the RSNA, MAP and heart rate (HR) in the Wistar rats and SHRs. There were no significant differences in the RSNA, MAP or HR between Wistar rats and SHRs at the two lowest doses of hexamethonium. However, the two highest doses of hexamethonium resulted in a greater reduction in the RSNA and MAP in SHRs compared with Wistar rats. There was a significant positive correlation between the alterations in RSNA and MAP in response to the intravenous injection of hexamethonium in the Wistar rats and SHRs. There were no significant differences in the timing of the maximal effects on RSNA, MAP or HR or in recovery following hexamethonium treatment. These results suggest that there is an association between the RSNA and MAP response to intravenous injection of hexamethonium and that the alterations in MAP in response to hexamethonium may be used to evaluate basal sympathetic nerve activity.
Rassias, Athos J; Guyre, Paul M; Yeager, Mark P
2011-12-01
We evaluated the differential impact of stress-associated vs high pharmacologic concentrations of hydrocortisone pretreatment on heart rate variability (HRV) during a subsequent systemic inflammatory stimulus. Healthy volunteers were randomized to receive placebo (Control) and hydrocortisone at 1.5 μg/kg per minute (STRESS) or at 3.0 μg/kg per minute (PHARM) as a 6-hour infusion. The STRESS dose was chosen to replicate the condition of physiologic adrenal cortical output during acute systemic stress. The PHARM dose was chosen to induce a supraphysiologic concentration of cortisol. The next day, all subjects received 2 ng/kg Escherichia coli endotoxin (lipopolysaccharide). Heart rate variability was analyzed with the statistic approximate entropy (ApEn). A lower ApEn correlates with decreased HRV. At the 3-hour nadir, the decrease in ApEn in the STRESS group was significantly less compared to placebo (P < .03), whereas ApEn in the PHARM group was not statistically different. We also found that the maximal decrease in ApEn preceded maximal increase in heart rate in all groups. The decrease in R-R interval was maximal at 4 hours, whereas the ApEn nadir was 1 hour earlier at 3 hours. Pretreatment with a stress dose of hydrocortisone but not a higher pharmacologic dose maintained a significantly higher ApEn after endotoxin exposure when compared to a placebo. In addition, decreases in ApEn preceded increases in heart rate. Copyright © 2011 Elsevier Inc. All rights reserved.
A simplified model of the source channel of the Leksell GammaKnife tested with PENELOPE.
Al-Dweri, Feras M O; Lallena, Antonio M; Vilches, Manuel
2004-06-21
Monte Carlo simulations using the code PENELOPE have been performed to test a simplified model of the source channel geometry of the Leksell GammaKnife. The characteristics of the radiation passing through the treatment helmets are analysed in detail. We have found that only primary particles emitted from the source with polar angles smaller than 3 degrees with respect to the beam axis are relevant for the dosimetry of the Gamma Knife. The photon trajectories reaching the output helmet collimators at (x, v, z = 236 mm) show strong correlations between rho = (x2 + y2)(1/2) and their polar angle theta, on one side, and between tan(-1)(y/x) and their azimuthal angle phi, on the other. This enables us to propose a simplified model which treats the full source channel as a mathematical collimator. This simplified model produces doses in good agreement with those found for the full geometry. In the region of maximal dose, the relative differences between both calculations are within 3%, for the 18 and 14 mm helmets, and 10%, for the 8 and 4 mm ones. Besides, the simplified model permits a strong reduction (larger than a factor 15) in the computational time.
Nilsson, Johnny E; Rosdahl, Hans G
2016-01-01
The purpose was to investigate the contribution of leg-muscle-generated forces to paddle force and kayak speed during maximal-effort flat-water paddling. Five elite male kayakers at national and international level participated. The participants warmed up at progressively increasing speeds and then performed a maximal-effort, nonrestricted paddling sequence. This was followed after 5 min rest by a maximal-effort paddling sequence with the leg action restricted--the knee joints "locked." Left- and right-side foot-bar and paddle forces were recorded with specially designed force devices. In addition, knee angular displacement of the right and left knees was recorded with electrogoniometric technique, and the kayak speed was calculated from GPS signals sampled at 5 Hz. The results showed that reduction in both push and pull foot-bar forces resulted in a reduction of 21% and 16% in mean paddle-stroke force and mean kayak speed, respectively. Thus, the contribution of foot-bar force from lower-limb action significantly contributes to kayakers' paddling performance.
Radiation dose management in thoracic CT: an international survey.
Molinari, Francesco; Tack, Denis M; Boiselle, Philip; Ngo, Long; Mueller-Mang, Christina; Litmanovich, Diana; Bankier, Alexander A
2013-01-01
We aimed to examine current practice patterns of international thoracic radiologists regarding radiation dose management in adult thoracic computed tomography (CT) examinations. An electronic questionnaire was sent to 800 members of five thoracic radiology societies in North America, Europe, Asia, and Latin America addressing radiation dose training and education, standard kVp and mAs settings for thoracic CT, dose reduction practices, clinical scenarios, and demographics. Of the 800 radiologists, 146 responded to our survey. Nearly half (66/146, 45% [95% confidence interval, 37%-53%]) had no formal training in dose reduction, with "self-study of the literature" being the most common form of training (54/146, 37% [29%-45%]). One hundred and seventeen (80% [74%-87%]) had automatic exposure control, and 76 (65% [56%-74%]) used it in all patients. Notably, most respondents (89% [84%-94%]) used a 120 to 125 kVp standard setting, whereas none used 140 kVp. The most common average dose-length-product (DLP) value was 150 to 249 mGy.cm (75/146, 51% [43%-59%]), and 59% (51%-67%) delivered less than 250 mGy.cm in a 70 kg patient. There was a tendency towards higher DLP values with multidetector-row CT. Age, gender, and pregnancy were associated more with dose reduction than weight and clinical indication. Efforts for reducing patient radiation dose are highly prevalent among thoracic radiologists. Areas for improvement include reduction of default tube current settings, reduction of anatomical scan coverage, greater use of automatic exposure control, and eventually, reduction of current reference dose values. Our study emphasizes the need for international guidelines to foster greater conformity in dose reduction by thoracic radiologists.
Ng, Juki; Chwalisz, Kristof; Carter, David C; Klein, Cheri E
2017-05-01
Elagolix is a nonpeptide, oral gonadotropin-releasing hormone (GnRH) antagonist being developed for sex-hormone-dependent diseases in women. We evaluated the pharmacokinetics and pharmacodynamics of elagolix. This study was a randomized, double-blind, placebo-controlled, multiple-ascending dose study in 45 healthy premenopausal women at a research unit. Elagolix [150 mg once daily or 100, 200, 300, or 400 mg twice daily (BID)] or placebo was administered for 21 days. Main outcome measures were elagolix pharmacokinetics, suppression of gonadotropics [follicle-stimulating hormone (FSH), luteinizing hormone (LH)] and ovarian hormones [estradiol (E2), progesterone (P)], and adverse events. Elagolix was rapidly absorbed after oral dosing, reaching maximum concentrations at 1.0 to 1.5 hours, with a half-life of 4 to 6 hours. FSH, LH, and E2 were suppressed within hours of elagolix administration on day 1. Dose-dependent suppression of E2 was observed, with maximum suppression achieved with elagolix 200 mg BID. Dose-dependent suppression of FSH and LH was also observed, with maximal or near-maximal suppression achieved at 300 mg BID and 200 mg BID, respectively. At elagolix doses ≥100 mg BID, P concentrations remained at anovulatory levels throughout 21 days of dosing. The most frequently reported adverse events were headache and hot flush. Elagolix administration allows for modulation of gonadotropin and ovarian hormone concentrations, from partial suppression at lower doses to nearly full suppression at higher doses. The results of this study provide a rationale for elagolix dose selection for treatment of sex hormone-dependent diseases in women. Copyright © 2017 Endocrine Society
Magellan Project: Evolving enhanced operations efficiency to maximize science value
NASA Technical Reports Server (NTRS)
Cheuvront, Allan R.; Neuman, James C.; Mckinney, J. Franklin
1994-01-01
Magellan has been one of NASA's most successful spacecraft, returning more science data than all planetary spacecraft combined. The Magellan Spacecraft Team (SCT) has maximized the science return with innovative operational techniques to overcome anomalies and to perform activities for which the spacecraft was not designed. Commanding the spacecraft was originally time consuming because the standard development process was envisioned as manual tasks. The Program understood that reducing mission operations costs were essential for an extended mission. Management created an environment which encouraged automation of routine tasks, allowing staff reduction while maximizing the science data returned. Data analysis and trending, command preparation, and command reviews are some of the tasks that were automated. The SCT has accommodated personnel reductions by improving operations efficiency while returning the maximum science data possible.
Jayasuriya, W J A B; Suresh, T S; Abeytunga, D; Fernando, G H; Wanigatunga, C A
2012-01-01
This study investigates the oral hypoglycemic activity of Pleurotus ostreatus (P.o.) and P. cystidiosus (P.c.) mushrooms on normal and alloxan-induced diabetic Wistar rats. Different doses (250, 500, 750, 1000, and 1250 mg/kg/body weight) of suspensions of freeze-dried and powdered (SFDP) P.o. and P.c. were administered to normal rats, and postprandial serum glucose levels were measured. Optimal time of activity was investigated using the dose 500 mg/kg. Hypoglycemic effect of a single dose of SFDP P.o. and P.c. (500 mg/kg) were investigated using diabetic male and female rats at different stages of estrous cycle and compared with metformin and glibenclamide. Chronic hypoglycemic activity of SFDP P.o. and P.c. (500 mg/kg) was studied using serum glucose levels and glycosylated hemoglobin levels. Maximally effective dose of SFDP P.o. and P.c. was 500 mg/kg. The highest reduction in the serum glucose level was observed 120 minutes after administration of mushrooms. A single dose of P.o. and P.c. significantly (P < 0.05) reduced the serum glucose levels of male diabetic rats. The hypoglycemic activity in female rats was highest in proestrous stage. The hypoglycemic effect of P.o. and P.c. is comparable with metformin and glibenclamide. Daily single administrations of P.o. and P.c. to diabetic rats exert apparent control on the homeostasis of blood glucose. SFDP P.o. and P.c. possessed marked and significant oral hypoglycemic activity. This study suggests the consumption of P.o. and P.c. mushrooms might bring health benefits to mankind as it shows hypoglycemic activity in rats.
Chen, Jing-Xu; Su, Yun-Ai; Bian, Qing-Tao; Wei, Li-He; Zhang, Rong-Zhen; Liu, Yan-Hong; Correll, Christoph; Soares, Jair C; Yang, Fu-De; Wang, Shao-Li; Zhang, Xiang-Yang
2015-08-01
Hyperprolactinemia is an unwanted adverse effect associated with several antipsychotics. The addition of partial dopamine receptor agonist aripiprazole may attenuate antipsychotic-induced hyperprolactinemia effectively. However, the ideal dosing regimen for this purpose is unknown. We aimed to evaluate the dose effects of adjunctive treatment with aripiprazole on prolactin levels and hyperprolactinemia in schizophrenia patients. Stable subjects 18-45 years old with schizophrenia and hyperprolactinemia (i.e., >24 ng/ml for females and >20 ng/ml for males) were randomly assigned to receive 8 weeks of placebo (n=30) or oral aripiprazole 5mg/day (n=30), 10mg/day (n=29), or 20mg/day (n=30) added on to fixed dose risperidone treatment. Serum prolactin levels were measured at baseline and after 2, 4 and 8 weeks; clinical symptoms and side effects were assessed at baseline and week 8 using the Positive and Negative Syndrome Scale, Clinical Global Impressions Severity scale, Barnes Akathisia Scale, Simpson-Angus Scale and UKU Side Effects Rating Scale. Of 119 randomized patients, 107 (89.9%) completed the 8-week study. At study end, all three aripiprazole doses resulted in significantly lower prolactin levels (beginning at week 2), higher response rates (≥30% prolactin reduction) and higher prolactin normalization rates than placebo. Effects were significantly greater in the 10 and 20mg/day groups than the 5mg/day group. No significant changes were observed in any treatment groups regarding psychopathology and adverse effect ratings. Adjunctive aripiprazole treatment was effective and safe for resolving risperidone-induced hyperprolactinemia, producing significant and almost maximal improvements by week 2 without significant effects on psychopathology and side effects. Copyright © 2015 Elsevier Ltd. All rights reserved.
Study of a non-diffusing radiochromic gel dosimeter for 3D radiation dose imaging
NASA Astrophysics Data System (ADS)
Marsden, Craig Michael
2000-12-01
This thesis investigates the potential of a new radiation gel dosimeter, based on nitro-blue tetrazolium (NBTZ) suspended in a gelatin mold. Unlike all Fricke based gel dosimeters this dosimeter does not suffer from diffusive loss of image stability. Images are obtained by an optical tomography method. Nitro blue tetrazolium is a common biological indicator that when irradiated in an aqueous medium undergoes reduction to a highly colored formazan, which has an absorbance maximum at 525nm. Tetrazolium is water soluble while the formazan product is insoluble. The formazan product sticks to the gelatin matrix and the dose image is maintained for three months. Methods to maximize the sensitivity of the system were evaluated. It was found that a chemical detergent, Triton X-100, in combination with sodium formate, increased the dosimeter sensitivity significantly. An initial G-value of formazan production for a dosimeter composed of 1mM NBTZ, gelatin, and water was on the order of 0.2. The addition of Triton and formate produced a G-value in excess of 5.0. The effects of NBTZ, triton, formate, and gel concentration were all investigated. All the gels provided linear dose vs. absorbance plots for doses from 0 to >100 Gy. It was determined that gel concentration had minimal if any effect on sensitivity. Sensitivity increased slightly with increasing NBTZ concentration. Triton and formate individually and together provided moderate to large increases in dosimeter sensitivity. The dosimeter described in this work can provide stable 3D radiation dose images for all modalities of radiation therapy equipment. Methods to increase sensitivity are developed and discussed.
Swift, Damon L.; Earnest, Conrad P.; Katzmarzyk, Peter T.; Rankinen, Tuomo; Blair, Steven N.; Church, Timothy S.
2011-01-01
Objective Abnormally elevated exercise blood pressure is associated with increased risk of cardiovascular disease. Aerobic exercise training has been shown to reduce exercise blood pressure. However, it is unknown if these improvements occur in a dose dependent manner. The purpose of the present study is to determine the effect of different doses of aerobic exercise training on exercise blood pressure in obese postmenopausal women. Methods Participants (n=404) were randomized to one of 4 groups: 4, 8, or 12 kilocalories per kilogram of energy expenditure per week (kcal/kg/week) or the non-exercise control group for 6 months. Exercise blood pressure was obtained during the 50 watts stage of a cycle ergometer maximal exercise test. Results There was a significant reduction in systolic blood pressure at 50 watts in the 4 kcal/kg/week (−10.9 mmHg, p< 0.001), 8 kcal/kg/week (−9.9 mmHg, p= 0.022), and 12 kcal/kg/week (−13.7 mmHg, p<0.001) compared to control (−4.2 mmHg). Only the highest exercise training dose significantly reduced diastolic blood pressure (−4.3 mmHg, p= 0.033) compared to control. Additionally, resting blood pressure was not altered following exercise training (p>0.05) compared to control, and was not associated with changes in exercise systolic (r=0.09, p=0.09) or diastolic (r=0.10, p=0.08) blood pressure. Conclusions Aerobic exercise training reduces exercise blood pressure and may be more modifiable than changes in resting blood pressure. A high dose of aerobic exercise is recommended to successfully reduce both exercise systolic and diastolic blood pressure, and therefore may attenuate the CVD risk associated with abnormally elevated exercise blood pressure. PMID:22547251
A method for deriving a 4D-interpolated balanced planning target for mobile tumor radiotherapy.
Roland, Teboh; Hales, Russell; McNutt, Todd; Wong, John; Simari, Patricio; Tryggestad, Erik
2012-01-01
Tumor control and normal tissue toxicity are strongly correlated to the tumor and normal tissue volumes receiving high prescribed dose levels in the course of radiotherapy. Planning target definition is, therefore, crucial to ensure favorable clinical outcomes. This is especially important for stereotactic body radiation therapy of lung cancers, characterized by high fractional doses and steep dose gradients. The shift in recent years from population-based to patient-specific treatment margins, as facilitated by the emergence of 4D medical imaging capabilities, is a major improvement. The commonly used motion-encompassing, or internal-target volume (ITV), target definition approach provides a high likelihood of coverage for the mobile tumor but inevitably exposes healthy tissue to high prescribed dose levels. The goal of this work was to generate an interpolated balanced planning target that takes into account both tumor coverage and normal tissue sparing from high prescribed dose levels, thereby improving on the ITV approach. For each 4DCT dataset, 4D deformable image registration was used to derive two bounding targets, namely, a 4D-intersection and a 4D-composite target which minimized normal tissue exposure to high prescribed dose levels and maximized tumor coverage, respectively. Through definition of an "effective overlap volume histogram" the authors derived an "interpolated balanced planning target" intended to balance normal tissue sparing from prescribed doses with tumor coverage. To demonstrate the dosimetric efficacy of the interpolated balanced planning target, the authors performed 4D treatment planning based on deformable image registration of 4D-CT data for five previously treated lung cancer patients. Two 4D plans were generated per patient, one based on the interpolated balanced planning target and the other based on the conventional ITV target. Plans were compared for tumor coverage and the degree of normal tissue sparing resulting from the new approach was quantified. Analysis of the 4D dose distributions from all five patients showed that while achieving tumor coverage comparable to the ITV approach, the new planning target definition resulted in reductions of lung V(10), V(20), and V(30) of 6.3% ± 1.7%, 10.6% ± 3.9%, and 12.9% ± 5.5%, respectively, as well as reductions in mean lung dose, mean dose to the GTV-ring and mean heart dose of 8.8% ± 2.5%, 7.2% ± 2.5%, and 10.6% ± 3.6%, respectively. The authors have developed a simple and systematic approach to generate a 4D-interpolated balanced planning target volume that implicitly incorporates the dynamics of respiratory-organ motion without requiring 4D-dose computation or optimization. Preliminary results based on 4D-CT data of five previously treated lung patients showed that this new planning target approach may improve normal tissue sparing without sacrificing tumor coverage.
ADVANTG Shielding Analysis for Closure Operations in an Open-Mode Repository
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bevill, Aaron M; Radulescu, Georgeta; Scaglione, John M
2013-01-01
en-mode repository concepts could require worker entry into access drifts after placement of fuel casks in order to perform activities related to backfill, plug emplacement, routine maintenance, or performance confirmation. An ideal emplacement-drift shielding configuration would minimize dose to workers while maximizing airflow through the emplacement drifts. This paper presents a preliminary investigation of the feasibility and effectiveness of radiation shielding concepts that could be employed to facilitate worker operations in an open-mode repository. The repository model for this study includes pressurized-water reactor fuel assemblies (60 GWd/MTU burnup, 40 year post-irradiation cooldown) in packages of 32 assemblies. The closest fuelmore » packages are 5 meters from dosimetry voxels in the access drift. The unshielded dose to workers in the access drift is 73.7 rem/hour. Prior work suggests that open-mode repository concepts similar to this one would require 15 m3/s of ventilation airflow. Shielding concepts considered here include partial concrete plugs, labyrinthine shields, and stainless steel photon attenuator grids. Maximum dose to workers in the access drift was estimated for each shielding concept using MCNP5 with variance reduction parameters generated by ADVANTG. Because airflow through the shielding is important for open-mode repositories, a semi-empirical estimate of the head loss due to each shielding configuration was also calculated. Airflow and shielding performance vary widely among the proposed shielding configurations. Although the partial plug configuration had the best airflow performance, it allowed dose rates 1500 greater than the specified target. Labyrinthine shielding concepts yield doses on the order of 1 mrem/hour with configurations that impose 3 to 11 J/kg head loss. Adding 1 cm lead lining to the airflow channels of labyrinthine designs further reduces the worker dose by 65% to 95%. Photon-attenuator concepts may reduce worker dose to as low as 29 mrem/hour with head loss on the order of 1.9 J/kg.« less
Linear energy transfer incorporated intensity modulated proton therapy optimization
NASA Astrophysics Data System (ADS)
Cao, Wenhua; Khabazian, Azin; Yepes, Pablo P.; Lim, Gino; Poenisch, Falk; Grosshans, David R.; Mohan, Radhe
2018-01-01
The purpose of this study was to investigate the feasibility of incorporating linear energy transfer (LET) into the optimization of intensity modulated proton therapy (IMPT) plans. Because increased LET correlates with increased biological effectiveness of protons, high LETs in target volumes and low LETs in critical structures and normal tissues are preferred in an IMPT plan. However, if not explicitly incorporated into the optimization criteria, different IMPT plans may yield similar physical dose distributions but greatly different LET, specifically dose-averaged LET, distributions. Conventionally, the IMPT optimization criteria (or cost function) only includes dose-based objectives in which the relative biological effectiveness (RBE) is assumed to have a constant value of 1.1. In this study, we added LET-based objectives for maximizing LET in target volumes and minimizing LET in critical structures and normal tissues. Due to the fractional programming nature of the resulting model, we used a variable reformulation approach so that the optimization process is computationally equivalent to conventional IMPT optimization. In this study, five brain tumor patients who had been treated with proton therapy at our institution were selected. Two plans were created for each patient based on the proposed LET-incorporated optimization (LETOpt) and the conventional dose-based optimization (DoseOpt). The optimized plans were compared in terms of both dose (assuming a constant RBE of 1.1 as adopted in clinical practice) and LET. Both optimization approaches were able to generate comparable dose distributions. The LET-incorporated optimization achieved not only pronounced reduction of LET values in critical organs, such as brainstem and optic chiasm, but also increased LET in target volumes, compared to the conventional dose-based optimization. However, on occasion, there was a need to tradeoff the acceptability of dose and LET distributions. Our conclusion is that the inclusion of LET-dependent criteria in the IMPT optimization could lead to similar dose distributions as the conventional optimization but superior LET distributions in target volumes and normal tissues. This may have substantial advantages in improving tumor control and reducing normal tissue toxicities.
Camacho-Cardenosa, Marta; Camacho-Cardenosa, Alba; Martínez Guardado, Ismael; Marcos-Serrano, Marta; Timon, Rafael; Olcina, Guillermo
2017-01-01
This pilot study had the aim to determine the effects of a new dose of maximal-intensity interval training in hypoxia in active adults. Twenty-four university student volunteers were randomly assigned to three groups: hypoxia group, normoxia group or control group. The eight training sessions consisted of 2 sets of 5 repeated sprints of 10 seconds with a recovery of 20 seconds between sprints and a recovery period of 10 minutes between sets. Body composition was measured following standard procedures. A blood sample was taken for an immediate hematocrit (HCT) and hemoglobin (Hb) concentration assessment. An all-out 3-ute test was performed to evaluate ventilation parameters and power. HCT and Hb were significantly higher for the hypoxia group in Post- and Det- (P=0.01; P=0.03). Fat mass percentage was significantly lower for the hypoxia group in both assessments (P=0.05; P=0.05). The hypoxia group underwent a significant increase in mean power after the recovery period. A new dose of 8 sessions of maximal-intensity interval training in hypoxia is enough to decrease the percentage of fat mass and to improve HCT and Hb parameters and mean muscle power in healthy and active adults.
[Examination of patient dose reduction in cardiovasucular X-ray systems with a metal filter].
Yasuda, Mitsuyoshi; Kato, Kyouichi; Tanabe, Nobuaki; Sakiyama, Koushi; Uchiyama, Yushi; Suzuki, Yoshiaki; Suzuki, Hiroshi; Nakazawa, Yasuo
2012-01-01
In interventional X-ray for cardiology of flat panel digital detector (FPD), the phenomenon that exposure dose was suddenly increased when a subject thickness was thickened was recognized. At that time, variable metal built-in filters in FPD were all off. Therefore, we examined whether dose reduction was possible without affecting a clinical image using metal filter (filter) which we have been conventionally using for dose reduction. About 45% dose reduction was achieved when we measured an exposure dose at 30 cm of acrylic thickness in the presence of a filter. In addition, we measured signal to noise ratio/contrast to noise ratio/a resolution limit by the visual evaluation, and there was no influence by filter usage. In the clinical examination, visual evaluation of image quality of coronary angiography (40 cases) using a 5-point evaluation scale by a physician was performed. As a result, filter usage did not influence the image quality (p=NS). Therefore, reduction of sudden increase of exposure dose was achieved without influencing an image quality by adding filter to FPD.
Whitehead, Ryan A; Schwarz, Stephan K W; Asiri, Yahya I; Fung, Timothy; Puil, Ernest; MacLeod, Bernard A
2015-12-01
The combination of propofol and an opioid analgesic is widely used for procedural sedation, as well as total IV anesthesia. However, opioids produce respiratory depression, a primary cause of death due to these agents. We recently reported on the antinociceptive actions of isovaline, a small nonbiogenic amino acid that does not readily cross the blood-brain barrier and acts on peripheral γ-aminobutyric acid type B receptors. Here, we explored the possibility that isovaline may be an effective and safe alternative to opioids as an adjunct to propofol for producing anesthesia. With approval from our Animal Care Committee, we conducted an in vivo study in adult female CD-1 mice using Dixon's "up-and-down" method for dose assessment. Animals received intraperitoneal saline, propofol, isovaline, fentanyl, or coadministration of propofol with isovaline or fentanyl. We assessed hypnosis by a loss of righting reflex and immobility by an absence of motor response to tail clip application. General anesthesia was defined as the presence of both hypnosis and immobility. We assessed conscious sedation as a decrease in time on a rotarod. The maximal dose without respiratory rates of <4 per minute, apnea, or death was defined as the maximal tolerated dose. Either isovaline or fentanyl coadministered with propofol at its half-maximal effective dose (ED50) for hypnosis produced general anesthesia (isovaline ED50, 96 mg/kg [95% confidence interval {CI}, 88-124 mg/kg]; fentanyl ED50, 0.12 mg/kg [95% CI, 0.08-3.5 mg/kg]). Propofol produced hypnosis (ED50, 124 mg/kg [95% CI, 84-3520 mg/kg]) but did not block responses to tail clip application. Neither isovaline nor fentanyl produced hypnosis at doses which produced immobility (isovaline ED50, 350 mg/kg [95% CI, 286-1120 mg/kg]; fentanyl ED50, 0.35 mg/kg [95% CI, 0.23-0.51 mg/kg]). Isovaline at its analgesic ED50, coadministered with a subhypnotic dose of propofol (40 mg/kg), did not exacerbate propofol-induced deficits in rotarod performance. The median maximal tolerated dose of fentanyl coadministered with the hypnotic ED50 of propofol was 11 mg/kg (95% CI, 8-18 mg/kg). Isovaline at a maximal deliverable (soluble) dose of 5000 mg/kg produced no apparent respiratory depression or other adverse effects. The novel analgesic, isovaline, coadministered with propofol, produced general anesthesia and conscious sedation in mice. The margin of safety for propofol-isovaline was considerably higher than that for propofol-fentanyl. This study's results show that propofol-based sedation and general anesthesia can be effectively and safely produced by replacing the conventional opioid component with a brain-impermeant peripherally acting γ-aminobutyric acid type B receptor agonist. The results provide proof of the principle of combining a peripheral analgesic with a centrally acting hypnotic to produce general anesthesia. This principle suggests a novel approach to clinical general anesthesia and conscious sedation.
Clerc, Pascaline; Carey, Gregory B.; Mehrabian, Zara; Wei, Michael; Hwang, Hyehyun; Girnun, Geoffrey D.; Chen, Hegang; Martin, Stuart S.; Polster, Brian M.
2012-01-01
Cells that exhibit an absolute dependence on the anti-apoptotic BCL-2 protein for survival are termed “primed for death” and are killed by the BCL-2 antagonist ABT-737. Many cancers exhibit a primed phenotype, including some that are resistant to conventional chemotherapy due to high BCL-2 expression. We show here that 1) stable BCL-2 overexpression alone can induce a primed for death state and 2) that an ABT-737-induced loss of functional cytochrome c from the electron transport chain causes a reduction in maximal respiration that is readily detectable by microplate-based respirometry. Stable BCL-2 overexpression sensitized non-tumorigenic MCF10A mammary epithelial cells to ABT-737-induced caspase-dependent apoptosis. Mitochondria within permeabilized BCL-2 overexpressing cells were selectively vulnerable to ABT-737-induced cytochrome c release compared to those from control-transfected cells, consistent with a primed state. ABT-737 treatment caused a dose-dependent impairment of maximal O2 consumption in MCF10A BCL-2 overexpressing cells but not in control-transfected cells or in immortalized mouse embryonic fibroblasts lacking both BAX and BAK. This impairment was rescued by delivering exogenous cytochrome c to mitochondria via saponin-mediated plasma membrane permeabilization. An ABT-737-induced reduction in maximal O2 consumption was also detectable in SP53, JeKo-1, and WEHI-231 B-cell lymphoma cell lines, with sensitivity correlating with BCL-2:MCL-1 ratio and with susceptibility (SP53 and JeKo-1) or resistance (WEHI-231) to ABT-737-induced apoptosis. Multiplexing respirometry assays to ELISA-based determination of cytochrome c redistribution confirmed that respiratory inhibition was associated with cytochrome c release. In summary, cell-based respiration assays were able to rapidly identify a primed for death state in cells with either artificially overexpressed or high endogenous BCL-2. Rapid detection of a primed for death state in individual cancers by “bioenergetics-based profiling” may eventually help identify the subset of patients with chemoresistant but primed tumors who can benefit from treatment that incorporates a BCL-2 antagonist. PMID:22880001
2013-01-01
Background To establish a generalized equivalent uniform dose (gEUD) -based prescription method for Image Guided Brachytherapy (IGBT) that reproduces the Gyn GEC-ESTRO WG (GGE) prescription for cervix carcinoma patients on CT images with limited soft tissue resolution. Methods The equivalence of two IGBT planning approaches was investigated in 20 patients who received external beam radiotherapy (EBT) and 5 concomitant high dose rate IGBT treatments. The GGE planning strategy based on dose to the most exposed 2 cm3 (D2cc) was used to derive criteria for the gEUD-based planning of the bladder and rectum. The safety of gEUD constraints in terms of GGE criteria was tested by maximizing dose to the gEUD constraints for individual fractions. Results The gEUD constraints of 3.55 Gy for the rectum and 5.19 Gy for the bladder were derived. Rectum and bladder gEUD-maximized plans resulted in D2cc averages very similar to the initial GGE criteria. Average D2ccs and EUDs from the full treatment course were comparable for the two techniques within both sets of normal tissue constraints. The same was found for the tumor doses. Conclusions The derived gEUD criteria for normal organs result in GGE-equivalent IGBT treatment plans. The gEUD-based planning considers the entire dose distribution of organs in contrast to a single dose-volume-histogram point. PMID:24225184
Vickers, Linda D
2010-05-01
This paper describes the method using Microsoft Excel (Microsoft Corporation One Microsoft Way Redmond, WA 98052-6399) to compute the 5% overall site X/Q value and the 95th percentile of the distribution of doses to the nearest maximally exposed offsite individual (MEOI) in accordance with guidance from DOE-STD-3009-1994 and U.S. NRC Regulatory Guide 1.145-1982. The accurate determination of the 5% overall site X/Q value is the most important factor in the computation of the 95th percentile of the distribution of doses to the nearest MEOI. This method should be used to validate software codes that compute the X/Q. The 95th percentile of the distribution of doses to the nearest MEOI must be compared to the U.S. DOE Evaluation Guide of 25 rem to determine the relative severity of hazard to the public from a postulated, unmitigated design basis accident that involves an offsite release of radioactive material.
Hamstring Muscle Fatigue and Central Motor Output during a Simulated Soccer Match
Marshall, Paul W. M.; Lovell, Ric; Jeppesen, Gitte K.; Andersen, Kristoffer; Siegler, Jason C.
2014-01-01
Purpose To examine changes in hamstring muscle fatigue and central motor output during a 90-minute simulated soccer match, and the concomitant changes in hamstring maximal torque and rate of torque development. Method Eight amateur male soccer players performed a 90-minute simulated soccer match, with measures performed at the start of and every 15-minutes during each half. Maximal torque (Nm) and rate of torque development (RTD; Nm.s–1) were calculated from maximal isometric knee flexor contractions performed at 10° of flexion. Hamstring peripheral fatigue was assessed from changes in the size and shape of the resting twitch (RT). Hamstring central motor output was quantified from voluntary activation (%) and normalized biceps femoris (BF) and medial hamstrings (MH) electromyographic amplitudes (EMG/M). Results Maximal torque was reduced at 45-minutes by 7.6±9.4% (p<0.05). RTD in time intervals of 0–25, 0–50, and 0–75 ms post-contraction onset were reduced after 15-minutes in the first-half between 29.6 to 46.2% (p<0.05), and were further reduced at the end of the second-half (p<0.05). Maximal EMG/M was reduced for biceps femoris only concomitant to the time-course of reductions in maximal torque (p = 0.007). The rate of EMG rise for BF and MH was reduced in early time periods (0–75 ms) post-contraction onset (p<0.05). No changes were observed for the size and shape of the RT, indicating no hamstring peripheral fatigue. Conclusion Centrally mediated reductions in maximal torque and rate of torque development provide insight into factors that may explain hamstring injury risk during soccer. Of particular interest were early reductions during the first-half of hamstring rate of torque development, and the decline in maximal EMG/M of biceps femoris in the latter stages of the half. These are important findings that may help explain why the hamstrings are particularly vulnerable to strain injury during soccer. PMID:25047547
Cao, Ying J; Caffo, Brian S; Fuchs, Edward J; Lee, Linda A; Du, Yong; Li, Liye; Bakshi, Rahul P; Macura, Katarzyna; Khan, Wasif A; Wahl, Richard L; Grohskopf, Lisa A; Hendrix, Craig W
2012-12-01
We sought to describe quantitatively the distribution of rectally administered gels and seminal fluid surrogates using novel concentration-distance parameters that could be repeated over time. These methods are needed to develop rationally rectal microbicides to target and prevent HIV infection. Eight subjects were dosed rectally with radiolabelled and gadolinium-labelled gels to simulate microbicide gel and seminal fluid. Rectal doses were given with and without simulated receptive anal intercourse. Twenty-four hour distribution was assessed with indirect single photon emission computed tomography (SPECT)/computed tomography (CT) and magnetic resonance imaging (MRI), and direct assessment via sigmoidoscopic brushes. Concentration-distance curves were generated using an algorithm for fitting SPECT data in three dimensions. Three novel concentration-distance parameters were defined to describe quantitatively the distribution of radiolabels: maximal distance (D(max) ), distance at maximal concentration (D(Cmax) ) and mean residence distance (D(ave) ). The SPECT/CT distribution of microbicide and semen surrogates was similar. Between 1 h and 24 h post dose, the surrogates migrated retrograde in all three parameters (relative to coccygeal level; geometric mean [95% confidence interval]): maximal distance (D(max) ), 10 cm (8.6-12) to 18 cm (13-26), distance at maximal concentration (D(Cmax) ), 3.8 cm (2.7-5.3) to 4.2 cm (2.8-6.3) and mean residence distance (D(ave) ), 4.3 cm (3.5-5.1) to 7.6 cm (5.3-11). Sigmoidoscopy and MRI correlated only roughly with SPECT/CT. Rectal microbicide surrogates migrated retrograde during the 24 h following dosing. Spatial kinetic parameters estimated using three dimensional curve fitting of distribution data should prove useful for evaluating rectal formulations of drugs for HIV prevention and other indications. © 2012 The Authors. British Journal of Clinical Pharmacology © 2012 The British Pharmacological Society.
Farrell, Colm; Hayes, Siobhan; Relan, Anurag; van Amersfoort, Edwin S; Pijpstra, Rienk; Hack, C Erik
2013-12-01
To characterize the pharmacokinetics (PK) of recombinant human C1 inhibitor (rhC1INH) in healthy volunteers and hereditary angioedema (HAE) patients. Plasma levels of C1INH following 294 administrations of rhC1INH in 133 subjects were fitted using nonlinear mixed-effects modelling. The model was used to simulate maximal C1INH levels for the proposed dosing scheme. A one-compartment model with Michaelis-Menten elimination kinetics described the data. Baseline C1INH levels were 0.901 [95% confidence interval (CI): 0.839-0.968] and 0.176 U ml(-1) (95% CI: 0.154-0.200) in healthy volunteers and HAE patients, respectively. The volume of distribution of rhC1INH was 2.86 l (95% CI: 2.68-3.03). The maximal rate of elimination and the concentration corresponding to half this maximal rate were 1.63 U ml(-1) h(-1) (95% CI: 1.41-1.88) and 1.60 U ml(-1) (95% CI: 1.14-2.24), respectively, for healthy volunteers and symptomatic HAE patients. The maximal elimination rate was 36% lower in asymptomatic HAE patients. Peak C1INH levels did not change upon repeated administration of rhC1INH. Bodyweight was found to be an important predictor of the volume of distribution. Simulations of the proposed dosing scheme predicted peak C1INH concentrations above the lower level of the normal range (0.7 U ml(-1)) for at least 94% of all patients. The population PK model for C1INH supports a dosing scheme on a 50 U kg(-1) basis up to 84 kg, with a fixed dose of 4200 U above 84 kg. The PK of rhC1INH following repeat administration are consistent with the PK following the first administration. © 2013 The British Pharmacological Society.
Population pharmacokinetics of recombinant human C1 inhibitor in patients with hereditary angioedema
Farrell, Colm; Hayes, Siobhan; Relan, Anurag; van Amersfoort, Edwin S; Pijpstra, Rienk; Hack, C Erik
2013-01-01
Aims To characterize the pharmacokinetics (PK) of recombinant human C1 inhibitor (rhC1INH) in healthy volunteers and hereditary angioedema (HAE) patients. Methods Plasma levels of C1INH following 294 administrations of rhC1INH in 133 subjects were fitted using nonlinear mixed-effects modelling. The model was used to simulate maximal C1INH levels for the proposed dosing scheme. Results A one-compartment model with Michaelis–Menten elimination kinetics described the data. Baseline C1INH levels were 0.901 [95% confidence interval (CI): 0.839–0.968] and 0.176 U ml−1 (95% CI: 0.154–0.200) in healthy volunteers and HAE patients, respectively. The volume of distribution of rhC1INH was 2.86 l (95% CI: 2.68–3.03). The maximal rate of elimination and the concentration corresponding to half this maximal rate were 1.63 U ml−1 h−1 (95% CI: 1.41–1.88) and 1.60 U ml−1 (95% CI: 1.14–2.24), respectively, for healthy volunteers and symptomatic HAE patients. The maximal elimination rate was 36% lower in asymptomatic HAE patients. Peak C1INH levels did not change upon repeated administration of rhC1INH. Bodyweight was found to be an important predictor of the volume of distribution. Simulations of the proposed dosing scheme predicted peak C1INH concentrations above the lower level of the normal range (0.7 U ml−1) for at least 94% of all patients. Conclusions The population PK model for C1INH supports a dosing scheme on a 50 U kg−1 basis up to 84 kg, with a fixed dose of 4200 U above 84 kg. The PK of rhC1INH following repeat administration are consistent with the PK following the first administration. PMID:23594263
Analysis of the negative inotropic effect of acetylcholine on frog atrial fibres.
Nargeot, J; Garnier, D; Rougier, O
1981-03-01
Voltage-clamp experiments have been performed on frog atrial preparations in order to study the mechanism of the inotropic effect of acetylcholine (ACh) at various concentrations. The amplitude of the slow inward current (Is) is reduced even at low ACh concentrations; such low concentrations have little or no effect on potassium permeability. Dose-effect relationships for Is inhibition (Is/Is max) by ACh show a half amplitude dose (K0.5 around 8 X 10(-8) M ACh. The reduction of Is is attributed largely to a decrease of the maximal conductance of the slow channel (gs). Steady-state activation and inactivation parameters are not affected by ACh. Experiments in a Na-free solution (Na replaced by Li ions) or in a Ca-free solution (with EGTA) indicate that the "slow sodium current" is more sensitive to ACh than the "slow Ca current", although these two currents both seem to flow through the slow channel. The decrease of the phasic component of contraction observed in the presence of ACh is very well correlated with the decrease of Is (K0.5 = 8 X 10(-8) M ACh), while the increase of the tonic tension may be related to the outward potassium current induced by high concentrations of ACh. The significant difference between the half amplitude dose (K0.5) observed in the dose effect curves with ACh for Is inhibition (K0.5 = 8 X 10(-8) M) and for ACh-induced extra-current (K0.5 - 10(-6) M) may indicate the presence of two muscarinic receptors.
Demonstration of an N7 integrated fab process for metal oxide EUV photoresist
NASA Astrophysics Data System (ADS)
De Simone, Danilo; Mao, Ming; Kocsis, Michael; De Schepper, Peter; Lazzarino, Frederic; Vandenberghe, Geert; Stowers, Jason; Meyers, Stephen; Clark, Benjamin L.; Grenville, Andrew; Luong, Vinh; Yamashita, Fumiko; Parnell, Doni
2016-03-01
Inpria has developed a directly patternable metal oxide hard-mask as a robust, high-resolution photoresist for EUV lithography. In this paper we demonstrate the full integration of a baseline Inpria resist into an imec N7 BEOL block mask process module. We examine in detail both the lithography and etch patterning results. By leveraging the high differential etch resistance of metal oxide photoresists, we explore opportunities for process simplification and cost reduction. We review the imaging results from the imec N7 block mask patterns and its process windows as well as routes to maximize the process latitude, underlayer integration, etch transfer, cross sections, etch equipment integration from cross metal contamination standpoint and selective resist strip process. Finally, initial results from a higher sensitivity Inpria resist are also reported. A dose to size of 19 mJ/cm2 was achieved to print pillars as small as 21nm.
Patients with Fabry Disease after Enzyme Replacement Therapy Dose Reduction Versus Treatment Switch
Krämer, Johannes; Duning, Thomas; Lenders, Malte; Canaan-Kühl, Sima; Krebs, Alice; González, Hans Guerrero; Sommer, Claudia; Üçeyler, Nurcan; Niemann, Markus; Störk, Stefan; Schelleckes, Michael; Reiermann, Stefanie; Stypmann, Jörg; Brand, Stefan-Martin; Wanner, Christoph; Brand, Eva
2014-01-01
Because of the shortage of agalsidase-beta in 2009, many patients with Fabry disease were treated with lower doses or were switched to agalsidase-alfa. This observational study assessed end-organ damage and clinical symptoms during dose reduction or switch to agalsidase-alfa. A total of 105 adult patients with Fabry disease who had received agalsidase-beta (1.0 mg/kg body weight) for ≥1 year were nonrandomly assigned to continue this treatment regimen (regular-dose group, n=38), receive a reduced dose of 0.3–0.5 mg/kg (dose-reduction group, n=29), or switch to 0.2 mg/kg agalsidase-alfa (switch group) and were followed prospectively for 1 year. We assessed clinical events (death, myocardial infarction, severe arrhythmia, stroke, progression to ESRD); changes in cardiac, renal, and neurologic function; and Fabry-related symptoms (neuropathic pain, hypohidrosis, diarrhea, and disease severity scores). Organ function and Fabry-related symptoms remained stable in the regular-dose group. In contrast, estimated GFR decreased by about 3 ml/min per 1.73 m2 (P=0.01) in the dose-reduction group, and the median albumin-to-creatinine ratio increased from 114 (0–606) mg/g to 216 (0–2062) mg/g (P=0.03) in the switch group. Furthermore, mean Mainz Severity Score Index scores and frequencies of pain attacks, chronic pain, gastrointestinal pain, and diarrhea increased significantly in the dose-reduction and switch groups. In conclusion, patients receiving regular agalsidase-beta dose had a stable disease course, but dose reduction led to worsening of renal function and symptoms. Switching to agalsidase-alfa is safe, but microalbuminuria may progress and Fabry-related symptoms may deteriorate. PMID:24556354
Patients with Fabry disease after enzyme replacement therapy dose reduction versus treatment switch.
Weidemann, Frank; Krämer, Johannes; Duning, Thomas; Lenders, Malte; Canaan-Kühl, Sima; Krebs, Alice; Guerrero González, Hans; Sommer, Claudia; Üçeyler, Nurcan; Niemann, Markus; Störk, Stefan; Schelleckes, Michael; Reiermann, Stefanie; Stypmann, Jörg; Brand, Stefan-Martin; Wanner, Christoph; Brand, Eva
2014-04-01
Because of the shortage of agalsidase-beta in 2009, many patients with Fabry disease were treated with lower doses or were switched to agalsidase-alfa. This observational study assessed end-organ damage and clinical symptoms during dose reduction or switch to agalsidase-alfa. A total of 105 adult patients with Fabry disease who had received agalsidase-beta (1.0 mg/kg body weight) for ≥1 year were nonrandomly assigned to continue this treatment regimen (regular-dose group, n=38), receive a reduced dose of 0.3-0.5 mg/kg (dose-reduction group, n=29), or switch to 0.2 mg/kg agalsidase-alfa (switch group) and were followed prospectively for 1 year. We assessed clinical events (death, myocardial infarction, severe arrhythmia, stroke, progression to ESRD); changes in cardiac, renal, and neurologic function; and Fabry-related symptoms (neuropathic pain, hypohidrosis, diarrhea, and disease severity scores). Organ function and Fabry-related symptoms remained stable in the regular-dose group. In contrast, estimated GFR decreased by about 3 ml/min per 1.73 m(2) (P=0.01) in the dose-reduction group, and the median albumin-to-creatinine ratio increased from 114 (0-606) mg/g to 216 (0-2062) mg/g (P=0.03) in the switch group. Furthermore, mean Mainz Severity Score Index scores and frequencies of pain attacks, chronic pain, gastrointestinal pain, and diarrhea increased significantly in the dose-reduction and switch groups. In conclusion, patients receiving regular agalsidase-beta dose had a stable disease course, but dose reduction led to worsening of renal function and symptoms. Switching to agalsidase-alfa is safe, but microalbuminuria may progress and Fabry-related symptoms may deteriorate.
Sakurai, T; Kawamata, R; Kozai, Y; Kaku, Y; Nakamura, K; Saito, M; Wakao, H; Kashima, I
2010-05-01
The aim of the study was to clarify the change in image quality upon X-ray dose reduction and to re-analyse the possibility of X-ray dose reduction in photostimulable phosphor luminescence (PSPL) X-ray imaging systems. In addition, the study attempted to verify the usefulness of multiobjective frequency processing (MFP) and flexible noise control (FNC) for X-ray dose reduction. Three PSPL X-ray imaging systems were used in this study. Modulation transfer function (MTF), noise equivalent number of quanta (NEQ) and detective quantum efficiency (DQE) were evaluated to compare the basic physical performance of each system. Subjective visual evaluation of diagnostic ability for normal anatomical structures was performed. The NEQ, DQE and diagnostic ability were evaluated at base X-ray dose, and 1/3, 1/10 and 1/20 of the base X-ray dose. The MTF of the systems did not differ significantly. The NEQ and DQE did not necessarily depend on the pixel size of the system. The images from all three systems had a higher diagnostic utility compared with conventional film images at the base and 1/3 X-ray doses. The subjective image quality was better at the base X-ray dose than at 1/3 of the base dose in all systems. The MFP and FNC-processed images had a higher diagnostic utility than the images without MFP and FNC. The use of PSPL imaging systems may allow a reduction in the X-ray dose to one-third of that required for conventional film. It is suggested that MFP and FNC are useful for radiation dose reduction.
D'Onofrio, Antonio; Palmisano, Pietro; Rapacciuolo, Antonio; Ammendola, Ernesto; Calò, Leonardo; Ruocco, Antonio; Bianchi, Valter; Maresca, Fabio; Del Giorno, Giuseppe; Martino, Annamaria; Mauro, Ciro; Campari, Monica; Valsecchi, Sergio; Accogli, Michele
2017-06-01
Many patients fail to receive β-blockers before cardiac resynchronization therapy defibrillator (CRT-D) implantation, or receive them at a suboptimal dose, and require optimization after implantation. We assessed the effectiveness of a structured program for β-blocker titration in CRT-D patients followed up by means of conventional in-clinic visits or remote monitoring. 130 patients undergoing CRT implantation and treated according to the standard practice of the centers were included as a control group. A second group of 124 CRT-D candidates (Study Group) underwent up-titration visits every 2weeks after implantation (target dose: 10mg/day of bisoprolol or 50mg/day of carvedilol). In the Study Group, remote monitoring was undertaken in 66 patients, who received additional equipment for daily transmission of weight and blood pressure data, and scheduled titration telephone calls. In the Control Group, the maximal dose of β-blockers was being administered to 12 (9%) patients on implantation and 21 (16%) on 6-month follow-up examination (p>0.05). In the Study Group, 25 (20%) patients were receiving the maximal dose of β-blockers on implantation and 72 (58%) on follow-up examination (p<0.001). The 66 Study Group patients on remote monitoring underwent fewer in-clinic visits (p=0.034). Of these, 50 (76%) were on the maximal dose after remote up-titration (versus 38% of patients followed up conventionally, p<0.001). The decrease in left ventricular end-systolic volume was larger in the Study Group (p=0.040). The program for β-blocker up-titration increased the number of patients reaching the target dose and improved the response to the therapy. The use of remote monitoring and daily transfer of weight and blood pressure data facilitated β-blocker titration. URL: http://clinicaltrials.gov/ Identifier: NCT02173028. Copyright © 2017. Published by Elsevier B.V.
Safety and Feasibility of Long-term Intravenous Sodium Nitrite Infusion in Healthy Volunteers
Pluta, Ryszard M.; Oldfield, Edward H.; Bakhtian, Kamran D.; Fathi, Ali Reza; Smith, René K.; DeVroom, Hetty L.; Nahavandi, Masoud; Woo, Sukyung; Figg, William D.; Lonser, Russell R.
2011-01-01
Background Infusion of sodium nitrite could provide sustained therapeutic concentrations of nitric oxide (NO) for the treatment of a variety of vascular disorders. The study was developed to determine the safety and feasibility of prolonged sodium nitrite infusion. Methodology Healthy volunteers, aged 21 to 60 years old, were candidates for the study performed at the National Institutes of Health (NIH; protocol 05-N-0075) between July 2007 and August 2008. All subjects provided written consent to participate. Twelve subjects (5 males, 7 females; mean age, 38.8±9.2 years (range, 21–56 years)) were intravenously infused with increasing doses of sodium nitrite for 48 hours (starting dose at 4.2 µg/kg/hr; maximal dose of 533.8 µg/kg/hr). Clinical, physiologic and laboratory data before, during and after infusion were analyzed. Findings The maximal tolerated dose for intravenous infusion of sodium nitrite was 267 µg/kg/hr. Dose limiting toxicity occurred at 446 µg/kg/hr. Toxicity included a transient asymptomatic decrease of mean arterial blood pressure (more than 15 mmHg) and/or an asymptomatic increase of methemoglobin level above 5%. Nitrite, nitrate, S-nitrosothiols concentrations in plasma and whole blood increased in all subjects and returned to preinfusion baseline values within 12 hours after cessation of the infusion. The mean half-life of nitrite estimated at maximal tolerated dose was 45.3 minutes for plasma and 51.4 minutes for whole blood. Conclusion Sodium nitrite can be safely infused intravenously at defined concentrations for prolonged intervals. These results should be valuable for developing studies to investigate new NO treatment paradigms for a variety of clinical disorders, including cerebral vasospasm after subarachnoid hemorrhage, and ischemia of the heart, liver, kidney and brain, as well as organ transplants, blood-brain barrier modulation and pulmonary hypertension. Clinical Trial Registration Information http://www.clinicaltrials.gov; NCT00103025 PMID:21249218
Gründker, Carsten; Günthert, Andreas R; Hellriegel, Martin; Emons, Günter
2004-11-01
The majority of human endometrial (>80%), ovarian (>80%) and breast (>50%) cancers express GnRH receptors. Their spontaneous and epidermal growth-factor-induced proliferation is dose- and time-dependently reduced by treatment with GnRH and its agonists. In this study, we demonstrate that the GnRH agonist triptorelin inhibits estradiol (E2)-induced cancer cell proliferation. The proliferation of quiescent estrogen receptor alpha (ER alpha)-/ER beta-positive, but not of ER alpha-negative/ER beta-positive endometrial, ovarian and breast cancer cell lines, was significantly stimulated (P<0.001) (ANOVA) after treatment with E2 (10(-8) M). This effect was time- and dose-dependently antagonized by simultaneous treatment with triptorelin. The inhibitory effect was maximal at 10(-5) M concentration of triptorelin (P<0.001). In addition, we could show that, in ER alpha-/ER beta-positive cell lines, E2 induces activation of serum response element (SRE) and expression of the immediate early-response gene c-fos. These effects were blocked by triptorelin (P<0.001). E2-induced activation of estrogen-response element (ERE) was not affected by triptorelin. The transcriptional activation of SRE by E2 is due to ER alpha activation of the mitogen-activated protein kinase (MAPK) pathway. This pathway is impeded by GnRH, resulting in a reduction of E2-induced SRE activation and, in consequence, a reduction of E2-induced c-fos expression. This causes downregulation of E2-induced cancer cell proliferation.
Azilsartan Medoxomil, an Angiotensin II Receptor Antagonist for the Treatment of Hypertension.
Hjermitslev, Marie; Grimm, Daniela G; Wehland, Markus; Simonsen, Ulf; Krüger, Marcus
2017-10-01
Azilsartan (AZL) medoxomil was approved by the United States Food and Drug Administration in 2011 for the treatment of hypertension and has shown promising results both in blood pressure (BP) reduction and in tolerability, but has not yet been taken into practice to the same extent as other angiotensin II receptor blockers (ARBs) that have been on the market for a longer period. AZL antagonizes the AT 1 receptor for angiotensin II (ANG II), whereas angiotensin-converting enzyme inhibitors block the conversion of angiotensin I to ANG II, but not alternative routes of formation of ANG II. The bioavailability of AZL is about 60% and it has a t max of 1.5-3 hr and a half-life of approximately 11 hr. With its IC 50 of 7.4 nM after 5 hr of drug washout in radioligand assays, AZL has a tighter and longer-lasting binding to the AT 1 receptor by several orders of magnitude than other ARBs, which might lead to a more effective reduction in BP. Clinical studies have revealed that AZL doses of 40 and 80 mg/day reduce BP significantly better than maximal clinical doses of valsartan or olmesartan, while being well tolerated and exhibiting a spectrum of adverse effects comparable to those of other ARBs. These properties of AZL might lower the risk of cardiovascular disease and thereby reduce mortality rates. However, the existing mortality studies have not found this correlation, which should be further investigated. © 2017 Nordic Association for the Publication of BCPT (former Nordic Pharmacological Society).
Wilson, Sharon M; Prasan, Ananth M; Virdi, Amy; Lassere, Marissa; Ison, Glenn; Ramsay, David R; Weaver, James C
2016-10-10
The aim of this study was to evaluate whether a real-time (RT) colour pictorial radiation dose monitoring system reduces patient skin and total radiation dose during coronary angiography and intervention. Patient demographics, procedural variables and radiation parameters were recorded before and after institution of the RT skin dose recording system. Peak skin dose as well as traditionally available measures of procedural radiation dose were compared. A total of 1,077 consecutive patients underwent coronary angiography, of whom 460 also had PCI. Institution of the RT skin dose recording system resulted in a 22% reduction in peak skin dose after accounting for confounding variables. Radiation dose reduction was most pronounced in those having PCI but was also seen over a range of subgroups including those with prior coronary artery bypass surgery, high BMI, and with radial arterial access. This was associated with a significant reduction in the number of patients placed at risk of skin damage. Similar reductions in parameters reflective of total radiation dose were also demonstrated after institution of RT radiation monitoring. Institution of an RT skin dose recording reduced patient peak skin and total radiation dose during coronary angiography and intervention. Consideration should be given to widespread adoption of this technology.
Kourlaba, Georgia; Dimopoulos, Meletios A; Pectasides, Dimitrios; Skarlos, Dimosthenis V; Gogas, Helen; Pentheroudakis, George; Koutras, Angelos; Fountzilas, George; Maniadakis, Nikos
2015-07-01
The aim of this study was to compare the effectiveness of prophylactic single fixed dose of pegfilgrastim and daily administration of filgrastim on febrile neutropenia (FN), severe neutropenia, treatment delay, and dose reduction in patients with breast cancer receiving dose-dense adjuvant chemotherapy. A retrospective cohort study with 1058 breast cancer patients matched by age and chemotherapy was conducted. The primary endpoints were FN, severe (grade 3, 4) neutropenia, dose reduction (>10 % reduction of the dose planned), and treatment delay (dose given more than 2 days later). Eighteen episodes of FN (3.4%) in the filgrastim group and 23 (4.3%) in the pegfilgrastim group (p = 0.500) were recorded. More than half of the total episodes (27/41) occurred during the first 4 cycles of treatment. Patients who received filgrastim were almost three times more likely to experience a severe neutropenia episode and were significantly more likely to experience a dose reduction (18.5%) compared to those who received pegfilgrastim (10.8%) (p < 0.001). The percentage of patients, who received their planned dose on time, was significantly lower in patients receiving filgrastim (58%) compared to those receiving pegfilgrastim (72.4%, p < 0.001). No significant difference was detected on FN rate between daily administration of filgrastim and single administration of pegfilgrastim. However, patients receiving pegfilgrastim had a significantly lower rate of severe neutropenia, as well as dose reduction and treatment delay, thus, achieving a higher dose density.
Dose reduction and cost-benefit analysis at Japan`s Tokai No. 2 Plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Humamoto, Hisao; Suzuki, Seishiro; Taniguchi, Kazufumi
1995-03-01
In the Tokai No. 2 power plant of the Japan Atomic Power Company, about 80% of the annual dose equivalent is received during periodic maintenance outages. A project group for dose reduction was organized at the company`s headquarters in 1986; in 1988, they proposed a five-year program to reduce by half the collective dose of 4 person-Sv per normal outage work. To achieve the target dose value, some dose-reduction measures were undertaken, namely, permanent radiation shielding, decontamination, automatic, operating machines, and ALARA organization. As the result, the collective dose from normal outage work was 1.6 person-Sv in 1992, which wasmore » less than the initial target value.« less
Patino, Manuel; Fuentes, Jorge M; Hayano, Koichi; Kambadakone, Avinash R; Uyeda, Jennifer W; Sahani, Dushyant V
2015-02-01
OBJECTIVE. The objective of our study was to compare the performance of three hybrid iterative reconstruction techniques (IRTs) (ASiR, iDose4, SAFIRE) and their respective strengths for image noise reduction on low-dose CT examinations using filtered back projection (FBP) as the standard reference. Also, we compared the performance of these three hybrid IRTs with two model-based IRTs (Veo and IMR) for image noise reduction on low-dose examinations. MATERIALS AND METHODS. An anthropomorphic abdomen phantom was scanned at 100 and 120 kVp and different tube current-exposure time products (25-100 mAs) on three CT systems (for ASiR and Veo, Discovery CT750 HD; for iDose4 and IMR, Brilliance iCT; and for SAFIRE, Somatom Definition Flash). Images were reconstructed using FBP and using IRTs at various strengths. Nine noise measurements (mean ROI size, 423 mm(2)) on extracolonic fat for the different strengths of IRTs were recorded and compared with FBP using ANOVA. Radiation dose, which was measured as the volume CT dose index and dose-length product, was also compared. RESULTS. There were no significant differences in radiation dose and image noise among the scanners when FBP was used (p > 0.05). Gradual image noise reduction was observed with each increasing increment of hybrid IRT strength, with a maximum noise suppression of approximately 50% (48.2-53.9%). Similar noise reduction was achieved on the scanners by applying specific hybrid IRT strengths. Maximum noise reduction was higher on model-based IRTs (68.3-81.1%) than hybrid IRTs (48.2-53.9%) (p < 0.05). CONCLUSION. When constant scanning parameters are used, radiation dose and image noise on FBP are similar for CT scanners made by different manufacturers. Significant image noise reduction is achieved on low-dose CT examinations rendered with IRTs. The image noise on various scanners can be matched by applying specific hybrid IRT strengths. Model-based IRTs attain substantially higher noise reduction than hybrid IRTs irrespective of the radiation dose.
Tallis, Jason; James, Rob S; Little, Alexander G; Cox, Val M; Duncan, Michael J; Seebacher, Frank
2014-09-15
Previous isolated muscle studies examining the effects of ageing on contractility have used isometric protocols, which have been shown to have poor relevance to dynamic muscle performance in vivo. The present study uniquely uses the work-loop technique for a more realistic estimation of in vivo muscle function to examine changes in mammalian skeletal muscle mechanical properties with age. Measurements of maximal isometric stress, activation and relaxation time, maximal power output, and sustained power output during repetitive activation and recovery are compared in locomotory extensor digitorum longus (EDL) and core diaphragm muscle isolated from 3-, 10-, 30-, and 50-wk-old female mice to examine the early onset of ageing. A progressive age-related reduction in maximal isometric stress that was of greater magnitude than the decrease in maximal power output occurred in both muscles. Maximal force and power developed earlier in diaphragm than EDL muscle but demonstrated a greater age-related decline. The present study indicates that ability to sustain skeletal muscle power output through repetitive contraction is age- and muscle-dependent, which may help rationalize previously reported equivocal results from examination of the effect of age on muscular endurance. The age-related decline in EDL muscle performance is prevalent without a significant reduction in muscle mass, and biochemical analysis of key marker enzymes suggests that although there is some evidence of a more oxidative fiber type, this is not the primary contributor to the early age-related reduction in muscle contractility. Copyright © 2014 the American Physiological Society.
Initial apixaban dosing in patients with atrial fibrillation.
Buchholz, Alexander; Ueberham, Laura; Gorczynska, Kaja; Dinov, Borislav; Hilbert, Sebastian; Dagres, Nikolaos; Husser, Daniela; Hindricks, Gerhard; Bollmann, Andreas
2018-05-01
Apixaban is a non-vitamin K oral anticoagulant approved for prevention of stroke and systemic embolism in patients with nonvalvular atrial fibrillation (AF). Current labeling recommends dose reduction based on patient age, weight, and renal function. The aim of this study was to analyze adherence to current labeling instructions concerning initial apixaban dosing in clinical practice and identify factors associated with inappropriate dose reduction. Patients with AF initiated on apixaban in 2016 were identified in the Heart Center Leipzig database. Records were screened to identify patient characteristics, prescribed apixaban dose, renal function, and further dosing-relevant secondary diagnoses and co-medication. We identified 569 consecutive patients with AF initiated on apixaban. In 301 (52.9%) patients, apixaban was prescribed in standard dose (5 mg b.i.d.) and in 268 (47.1%) in a reduced dose (2.5 mg b.i.d.). Of 268 patients receiving a reduced dose, 163 (60.8%) did not meet labeling criteria for dose reduction. In univariate and multivariate regression analysis, age (OR: 0.736, 95% CI: 0.664-0.816, P < 0.0001), patient weight (OR: 1.120, 95% CI: 1.076-1.166, P < 0.0001), and serum creatinine level (OR: 0.910, 95% CI: 0.881-0.940, P < 0.0001) were independent predictors for apixaban underdosage. In clinical practice, apixaban dosing is frequently inconsistent with labeling. Factors associated with inappropriate dose reduction are age, patient weight, and serum creatinine level, the same factors used as criteria for dose adjustment. However, in underdosed patients, the 3 factors did not meet the criteria for dose reduction. © 2018 Wiley Periodicals, Inc.
Keddy, Paul G. W.; Dunlop, Kate; Warford, Jordan; Samson, Michel L.; Jones, Quinton R. D.; Rupasinghe, H. P. Vasantha; Robertson, George S.
2012-01-01
We report here neuroprotective and anti-inflammatory effects of a flavonoid-enriched fraction isolated from the peel of Northern Spy apples (AF4) in a mouse of model of hypoxic-ischemic (HI) brain damage. Oral administration of AF4 (50 mg/kg, once daily for 3 days) prior to 50 min of HI completely prevented motor performance deficits assessed 14 days later that were associated with marked reductions in neuronal cell loss in the dorsal hippocampus and striatum. Pre-treatment with AF4 (5, 10, 25 or 50 mg/kg, p.o.; once daily for 3 days) produced a dose-dependent reduction in HI-induced hippocampal and striatal neuron cell loss, with 25 mg/kg being the lowest dose that achieved maximal neuroprotection. Comparison of the effects of 1, 3 or 7 doses of AF4 (25 mg/kg; p.o.) prior to HI revealed that at least 3 doses of AF4 were required before HI to reduce neuronal cell loss in both the dorsal hippocampus and striatum. Quantitative RT-PCR measurements revealed that the neuroprotective effects of AF4 (25 mg/kg; p.o.; once daily for 3 days) in the dorsal hippocampus were associated with a suppression of HI-induced increases in the expression of IL-1β, TNF-α and IL-6. AF4 pre-treatment enhanced mRNA levels for pro-survival proteins such as X-linked inhibitor of apoptosis and erythropoietin following HI in the dorsal hippocampus and striatum, respectively. Primary cultures of mouse cortical neurons incubated with AF4 (1 µg/ml), but not the same concentrations of either quercetin or quercetin-3-O-glucose or its metabolites, were resistant to cell death induced by oxygen glucose deprivation. These findings suggest that the inhibition of HI-induced brain injury produced by AF4 likely involves a transcriptional mechanism resulting from the co-operative actions of various phenolics in this fraction which not only reduce the expression of pro-inflammatory mediators but also enhance pro-survival gene signalling. PMID:23251498
Abila, B; Wilson, J F; Marshall, R W; Richens, A
1985-10-01
The effects of intravenous propranolol 100 micrograms kg-1, sotalol 500 micrograms kg-1, timolol 7.8 micrograms kg-1, atenolol 125 micrograms kg-1 and placebo on essential, physiological and isoprenaline-induced tremor were studied. These beta-adrenoceptor blocker doses produced equal reduction of standing-induced tachycardia in essential tremor patients. Atenolol produced significantly less reduction of essential and isoprenaline-induced tremor than the non-selective drugs, confirming the importance of beta 2-adrenoceptor blockade in these effects. Propranolol and sotalol produced equal maximal inhibition of isoprenaline-induced tremor but propranolol was significantly more effective in reducing essential tremor. The rate of development of the tremorolytic effect was similar in essential, physiological and isoprenaline-induced tremors but all tremor responses developed significantly more slowly than the heart rate responses. It is proposed that these results indicate that the tremorolytic activity of beta-adrenoceptor blockers in essential, physiological and isoprenaline-induced tremor is exerted via the same beta 2-adrenoceptors located in a deep peripheral compartment which is thought to be in the muscle spindles.
Abila, B; Wilson, J F; Marshall, R W; Richens, A
1985-01-01
The effects of intravenous propranolol 100 micrograms kg-1, sotalol 500 micrograms kg-1, timolol 7.8 micrograms kg-1, atenolol 125 micrograms kg-1 and placebo on essential, physiological and isoprenaline-induced tremor were studied. These beta-adrenoceptor blocker doses produced equal reduction of standing-induced tachycardia in essential tremor patients. Atenolol produced significantly less reduction of essential and isoprenaline-induced tremor than the non-selective drugs, confirming the importance of beta 2-adrenoceptor blockade in these effects. Propranolol and sotalol produced equal maximal inhibition of isoprenaline-induced tremor but propranolol was significantly more effective in reducing essential tremor. The rate of development of the tremorolytic effect was similar in essential, physiological and isoprenaline-induced tremors but all tremor responses developed significantly more slowly than the heart rate responses. It is proposed that these results indicate that the tremorolytic activity of beta-adrenoceptor blockers in essential, physiological and isoprenaline-induced tremor is exerted via the same beta 2-adrenoceptors located in a deep peripheral compartment which is thought to be in the muscle spindles. PMID:2866785
Li, Ke; Tang, Jie; Chen, Guang-Hong
2014-04-01
To reduce radiation dose in CT imaging, the statistical model based iterative reconstruction (MBIR) method has been introduced for clinical use. Based on the principle of MBIR and its nonlinear nature, the noise performance of MBIR is expected to be different from that of the well-understood filtered backprojection (FBP) reconstruction method. The purpose of this work is to experimentally assess the unique noise characteristics of MBIR using a state-of-the-art clinical CT system. Three physical phantoms, including a water cylinder and two pediatric head phantoms, were scanned in axial scanning mode using a 64-slice CT scanner (Discovery CT750 HD, GE Healthcare, Waukesha, WI) at seven different mAs levels (5, 12.5, 25, 50, 100, 200, 300). At each mAs level, each phantom was repeatedly scanned 50 times to generate an image ensemble for noise analysis. Both the FBP method with a standard kernel and the MBIR method (Veo(®), GE Healthcare, Waukesha, WI) were used for CT image reconstruction. Three-dimensional (3D) noise power spectrum (NPS), two-dimensional (2D) NPS, and zero-dimensional NPS (noise variance) were assessed both globally and locally. Noise magnitude, noise spatial correlation, noise spatial uniformity and their dose dependence were examined for the two reconstruction methods. (1) At each dose level and at each frequency, the magnitude of the NPS of MBIR was smaller than that of FBP. (2) While the shape of the NPS of FBP was dose-independent, the shape of the NPS of MBIR was strongly dose-dependent; lower dose lead to a "redder" NPS with a lower mean frequency value. (3) The noise standard deviation (σ) of MBIR and dose were found to be related through a power law of σ ∝ (dose)(-β) with the component β ≈ 0.25, which violated the classical σ ∝ (dose)(-0.5) power law in FBP. (4) With MBIR, noise reduction was most prominent for thin image slices. (5) MBIR lead to better noise spatial uniformity when compared with FBP. (6) A composite image generated from two MBIR images acquired at two different dose levels (D1 and D2) demonstrated lower noise than that of an image acquired at a dose level of D1+D2. The noise characteristics of the MBIR method are significantly different from those of the FBP method. The well known tradeoff relationship between CT image noise and radiation dose has been modified by MBIR to establish a more gradual dependence of noise on dose. Additionally, some other CT noise properties that had been well understood based on the linear system theory have also been altered by MBIR. Clinical CT scan protocols that had been optimized based on the classical CT noise properties need to be carefully re-evaluated for systems equipped with MBIR in order to maximize the method's potential clinical benefits in dose reduction and/or in CT image quality improvement. © 2014 American Association of Physicists in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Ke; Tang, Jie; Chen, Guang-Hong, E-mail: gchen7@wisc.edu
Purpose: To reduce radiation dose in CT imaging, the statistical model based iterative reconstruction (MBIR) method has been introduced for clinical use. Based on the principle of MBIR and its nonlinear nature, the noise performance of MBIR is expected to be different from that of the well-understood filtered backprojection (FBP) reconstruction method. The purpose of this work is to experimentally assess the unique noise characteristics of MBIR using a state-of-the-art clinical CT system. Methods: Three physical phantoms, including a water cylinder and two pediatric head phantoms, were scanned in axial scanning mode using a 64-slice CT scanner (Discovery CT750 HD,more » GE Healthcare, Waukesha, WI) at seven different mAs levels (5, 12.5, 25, 50, 100, 200, 300). At each mAs level, each phantom was repeatedly scanned 50 times to generate an image ensemble for noise analysis. Both the FBP method with a standard kernel and the MBIR method (Veo{sup ®}, GE Healthcare, Waukesha, WI) were used for CT image reconstruction. Three-dimensional (3D) noise power spectrum (NPS), two-dimensional (2D) NPS, and zero-dimensional NPS (noise variance) were assessed both globally and locally. Noise magnitude, noise spatial correlation, noise spatial uniformity and their dose dependence were examined for the two reconstruction methods. Results: (1) At each dose level and at each frequency, the magnitude of the NPS of MBIR was smaller than that of FBP. (2) While the shape of the NPS of FBP was dose-independent, the shape of the NPS of MBIR was strongly dose-dependent; lower dose lead to a “redder” NPS with a lower mean frequency value. (3) The noise standard deviation (σ) of MBIR and dose were found to be related through a power law of σ ∝ (dose){sup −β} with the component β ≈ 0.25, which violated the classical σ ∝ (dose){sup −0.5} power law in FBP. (4) With MBIR, noise reduction was most prominent for thin image slices. (5) MBIR lead to better noise spatial uniformity when compared with FBP. (6) A composite image generated from two MBIR images acquired at two different dose levels (D1 and D2) demonstrated lower noise than that of an image acquired at a dose level of D1+D2. Conclusions: The noise characteristics of the MBIR method are significantly different from those of the FBP method. The well known tradeoff relationship between CT image noise and radiation dose has been modified by MBIR to establish a more gradual dependence of noise on dose. Additionally, some other CT noise properties that had been well understood based on the linear system theory have also been altered by MBIR. Clinical CT scan protocols that had been optimized based on the classical CT noise properties need to be carefully re-evaluated for systems equipped with MBIR in order to maximize the method's potential clinical benefits in dose reduction and/or in CT image quality improvement.« less
Dynamic X-ray diffraction sampling for protein crystal positioning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scarborough, Nicole M.; Godaliyadda, G. M. Dilshan P.; Ye, Dong Hye
A sparse supervised learning approach for dynamic sampling (SLADS) is described for dose reduction in diffraction-based protein crystal positioning. Crystal centering is typically a prerequisite for macromolecular diffraction at synchrotron facilities, with X-ray diffraction mapping growing in popularity as a mechanism for localization. In X-ray raster scanning, diffraction is used to identify the crystal positions based on the detection of Bragg-like peaks in the scattering patterns; however, this additional X-ray exposure may result in detectable damage to the crystal prior to data collection. Dynamic sampling, in which preceding measurements inform the next most information-rich location to probe for image reconstruction,more » significantly reduced the X-ray dose experienced by protein crystals during positioning by diffraction raster scanning. The SLADS algorithm implemented herein is designed for single-pixel measurements and can select a new location to measure. In each step of SLADS, the algorithm selects the pixel, which, when measured, maximizes the expected reduction in distortion given previous measurements. Ground-truth diffraction data were obtained for a 5 µm-diameter beam and SLADS reconstructed the image sampling 31% of the total volume and only 9% of the interior of the crystal greatly reducing the X-ray dosage on the crystal. Furthermore, by usingin situtwo-photon-excited fluorescence microscopy measurements as a surrogate for diffraction imaging with a 1 µm-diameter beam, the SLADS algorithm enabled image reconstruction from a 7% sampling of the total volume and 12% sampling of the interior of the crystal. When implemented into the beamline at Argonne National Laboratory, without ground-truth images, an acceptable reconstruction was obtained with 3% of the image sampled and approximately 5% of the crystal. The incorporation of SLADS into X-ray diffraction acquisitions has the potential to significantly minimize the impact of X-ray exposure on the crystal by limiting the dose and area exposed for image reconstruction and crystal positioning using data collection hardware present in most macromolecular crystallography end-stations.« less
Dynamic X-ray diffraction sampling for protein crystal positioning
Scarborough, Nicole M.; Godaliyadda, G. M. Dilshan P.; Ye, Dong Hye; ...
2017-01-01
A sparse supervised learning approach for dynamic sampling (SLADS) is described for dose reduction in diffraction-based protein crystal positioning. Crystal centering is typically a prerequisite for macromolecular diffraction at synchrotron facilities, with X-ray diffraction mapping growing in popularity as a mechanism for localization. In X-ray raster scanning, diffraction is used to identify the crystal positions based on the detection of Bragg-like peaks in the scattering patterns; however, this additional X-ray exposure may result in detectable damage to the crystal prior to data collection. Dynamic sampling, in which preceding measurements inform the next most information-rich location to probe for image reconstruction,more » significantly reduced the X-ray dose experienced by protein crystals during positioning by diffraction raster scanning. The SLADS algorithm implemented herein is designed for single-pixel measurements and can select a new location to measure. In each step of SLADS, the algorithm selects the pixel, which, when measured, maximizes the expected reduction in distortion given previous measurements. Ground-truth diffraction data were obtained for a 5 µm-diameter beam and SLADS reconstructed the image sampling 31% of the total volume and only 9% of the interior of the crystal greatly reducing the X-ray dosage on the crystal. Furthermore, by usingin situtwo-photon-excited fluorescence microscopy measurements as a surrogate for diffraction imaging with a 1 µm-diameter beam, the SLADS algorithm enabled image reconstruction from a 7% sampling of the total volume and 12% sampling of the interior of the crystal. When implemented into the beamline at Argonne National Laboratory, without ground-truth images, an acceptable reconstruction was obtained with 3% of the image sampled and approximately 5% of the crystal. The incorporation of SLADS into X-ray diffraction acquisitions has the potential to significantly minimize the impact of X-ray exposure on the crystal by limiting the dose and area exposed for image reconstruction and crystal positioning using data collection hardware present in most macromolecular crystallography end-stations.« less
Adamec, R E
1998-01-01
The anxiogenic beta-carboline, FG-7142, produces intense anxiety in humans and anxiety-like behavior in animals. FG-7142 also mimics the effects of exogenous stressors. In cats, FG-7142 lastingly changes defensive and aggressive behavior. Long-term potentiation (LTP) of neural transmission between limbic structures known to modulate feline defensive response to threat accompany behavioral changes. A series of three reports describes experiments designed to test the hypothesis that behavioral changes depend upon an N-methyl-D-aspartate (NMDA) receptor-based LTP of efferent transmission from the amygdala. This first study characterizes the dose and time effects of injection of the NMDA receptor blocker 7-amino-phosphono-heptanoic acid (AP7) on efferent transmission from the cat amygdala to the ventromedial hypothalamus (VMH). Effects of doses of 0.5-10mg/kg (i.v.) of AP7 on potentials evoked in the VMH by single pulse stimulation of the basal amygdala were examined. In order to localize the action of the drug, concurrent measurements were taken of potentials evoked in the VMH by stimulation of the efferent fibers from the amygdala to the VMH (ventral amygdalofugal pathway, VAF). There was a dose-dependent reduction in the amygdalo-VMH evoked potential. The greatest reduction occurred at 5 mg/kg. Effects peaked at 10 min, and persisted for at least 1 h after injection. In contrast, AP7 increased the VAF-VMH-evoked potential at 10 min after injection, with a maximal increase at 5mg/kg. The data suggest that NMDA receptors intrinsic to the amygdala modulate excitatory efferent transmission from amygdala to VMH in the cat. It is speculated that a glutamatergic projection to gamma-aminobutyric acid tonic inhibitory systems in the VMH accounts for the VAF-VMH results.
Dynamic X-ray diffraction sampling for protein crystal positioning
Scarborough, Nicole M.; Godaliyadda, G. M. Dilshan P.; Ye, Dong Hye; Kissick, David J.; Zhang, Shijie; Newman, Justin A.; Sheedlo, Michael J.; Chowdhury, Azhad U.; Fischetti, Robert F.; Das, Chittaranjan; Buzzard, Gregery T.; Bouman, Charles A.; Simpson, Garth J.
2017-01-01
A sparse supervised learning approach for dynamic sampling (SLADS) is described for dose reduction in diffraction-based protein crystal positioning. Crystal centering is typically a prerequisite for macromolecular diffraction at synchrotron facilities, with X-ray diffraction mapping growing in popularity as a mechanism for localization. In X-ray raster scanning, diffraction is used to identify the crystal positions based on the detection of Bragg-like peaks in the scattering patterns; however, this additional X-ray exposure may result in detectable damage to the crystal prior to data collection. Dynamic sampling, in which preceding measurements inform the next most information-rich location to probe for image reconstruction, significantly reduced the X-ray dose experienced by protein crystals during positioning by diffraction raster scanning. The SLADS algorithm implemented herein is designed for single-pixel measurements and can select a new location to measure. In each step of SLADS, the algorithm selects the pixel, which, when measured, maximizes the expected reduction in distortion given previous measurements. Ground-truth diffraction data were obtained for a 5 µm-diameter beam and SLADS reconstructed the image sampling 31% of the total volume and only 9% of the interior of the crystal greatly reducing the X-ray dosage on the crystal. Using in situ two-photon-excited fluorescence microscopy measurements as a surrogate for diffraction imaging with a 1 µm-diameter beam, the SLADS algorithm enabled image reconstruction from a 7% sampling of the total volume and 12% sampling of the interior of the crystal. When implemented into the beamline at Argonne National Laboratory, without ground-truth images, an acceptable reconstruction was obtained with 3% of the image sampled and approximately 5% of the crystal. The incorporation of SLADS into X-ray diffraction acquisitions has the potential to significantly minimize the impact of X-ray exposure on the crystal by limiting the dose and area exposed for image reconstruction and crystal positioning using data collection hardware present in most macromolecular crystallography end-stations. PMID:28009558
Dynamic X-ray diffraction sampling for protein crystal positioning.
Scarborough, Nicole M; Godaliyadda, G M Dilshan P; Ye, Dong Hye; Kissick, David J; Zhang, Shijie; Newman, Justin A; Sheedlo, Michael J; Chowdhury, Azhad U; Fischetti, Robert F; Das, Chittaranjan; Buzzard, Gregery T; Bouman, Charles A; Simpson, Garth J
2017-01-01
A sparse supervised learning approach for dynamic sampling (SLADS) is described for dose reduction in diffraction-based protein crystal positioning. Crystal centering is typically a prerequisite for macromolecular diffraction at synchrotron facilities, with X-ray diffraction mapping growing in popularity as a mechanism for localization. In X-ray raster scanning, diffraction is used to identify the crystal positions based on the detection of Bragg-like peaks in the scattering patterns; however, this additional X-ray exposure may result in detectable damage to the crystal prior to data collection. Dynamic sampling, in which preceding measurements inform the next most information-rich location to probe for image reconstruction, significantly reduced the X-ray dose experienced by protein crystals during positioning by diffraction raster scanning. The SLADS algorithm implemented herein is designed for single-pixel measurements and can select a new location to measure. In each step of SLADS, the algorithm selects the pixel, which, when measured, maximizes the expected reduction in distortion given previous measurements. Ground-truth diffraction data were obtained for a 5 µm-diameter beam and SLADS reconstructed the image sampling 31% of the total volume and only 9% of the interior of the crystal greatly reducing the X-ray dosage on the crystal. Using in situ two-photon-excited fluorescence microscopy measurements as a surrogate for diffraction imaging with a 1 µm-diameter beam, the SLADS algorithm enabled image reconstruction from a 7% sampling of the total volume and 12% sampling of the interior of the crystal. When implemented into the beamline at Argonne National Laboratory, without ground-truth images, an acceptable reconstruction was obtained with 3% of the image sampled and approximately 5% of the crystal. The incorporation of SLADS into X-ray diffraction acquisitions has the potential to significantly minimize the impact of X-ray exposure on the crystal by limiting the dose and area exposed for image reconstruction and crystal positioning using data collection hardware present in most macromolecular crystallography end-stations.
Schnydrig, Sabine; Korner, Lukas; Landweer, Svenja; Ernst, Beat; Walker, Gaby; Otten, Uwe; Kunz, Dieter
2007-12-11
Peripheral inflammation induced by intraperitoneal (i.p.) injection of Lipopolysaccharide (LPS) is known to cause functional impairments in the brain affecting memory and learning. One of mechanisms may be the interference with neurotrophin (NT) expression and function. In the current study we administered a single, high dose of LPS (3mg/kg, i.p.) into mice and investigated changes in brain-derived neurotrophic factor (BDNF) gene expression within 1-6 days after LPS injection. Crude synaptosomes were isolated from brain tissue and subjected to Western-blot analyses. We found transient reductions in synaptosomal proBDNF- and BDNF protein expression, with a maximal decrease at day 3 as compared to saline injected controls. The time course of reduction of BDNF mRNA in whole brain extracts parallels the decrease in protein levels in synaptosomes. LPS effects in the central nervous system (CNS) are known to crucially involve the activation of the hypothalamic-pituitary-adrenal (HPA) axis. We analysed the time course of corticotropin releasing hormone (CRH)- and proopiomelanocortin (POMC) mRNA expression. As observed for BDNF-, CRH- and POMC mRNA levels are also significantly reduced on day 3 indicating a comparable time course. These results suggest that peripheral inflammation causes a reduction of trophic supply in the brain, including BDNF at synaptic sites. The mechanisms involved could be a negative feedback of the activated HPA axis.
NASA Astrophysics Data System (ADS)
Fu, Wanyi; Sturgeon, Gregory M.; Agasthya, Greeshma; Segars, W. Paul; Kapadia, Anuj J.; Samei, Ehsan
2017-03-01
This study aimed to estimate the organ dose reduction potential for organ-dose-based tube current modulated (ODM) thoracic CT with wide dose reduction arc. Twenty-one computational anthropomorphic phantoms (XCAT, age range: 27- 75 years, weight range: 52.0-105.8 kg) were used to create a virtual patient population with clinical anatomic variations. For each phantom, two breast tissue compositions were simulated: 50/50 and 20/80 (glandular-to-adipose ratio). A validated Monte Carlo program was used to estimate the organ dose for standard tube current modulation (TCM) (SmartmA, GE Healthcare) and ODM (GE Healthcare) for a commercial CT scanner (Revolution, GE Healthcare) with explicitly modeled tube current modulation profile, scanner geometry, bowtie filtration, and source spectrum. Organ dose was determined using a typical clinical thoracic CT protocol. Both organ dose and CTDIvol-to-organ dose conversion coefficients (h factors) were compared between TCM and ODM. ODM significantly reduced all radiosensitive organ doses (p<0.01). The breast dose was reduced by 30+/-2%. For h factors, organs in the anterior region (e.g. thyroid, stomach) exhibited substantial decreases, and the medial, distributed, and posterior region either saw an increase or no significant change. The organ-dose-based tube current modulation significantly reduced organ doses especially for radiosensitive superficial anterior organs such as the breasts.
Determinants of choice for pigeons and humans on concurrent-chains schedules of reinforcement.
Belke, T W; Pierce, W D; Powell, R A
1989-09-01
Concurrent-chains schedules of reinforcement were arranged for humans and pigeons. Responses of humans were reinforced with tokens exchangeable for money, and key pecks of 4 birds were reinforced with food. Variable-interval 30-s and 40-s schedules operated in the terminal links of the chains. Condition 1 exposed subjects to variable-interval 90-s and variable-interval 30-s initial links, respectively. Conditions 2 and 3 arranged equal initial-link schedules of 40 s or 120 s. Experimental conditions tested the descriptive adequacy of five equations: reinforcement density, delay reduction, modified delay reduction, matching and maximization. Results based on choice proportions and switch rates during the initial links showed that pigeons behaved in accord with delay-reduction models, whereas humans maximized overall rate of reinforcement. As discussed by Logue and associates in self-control research, different types of reinforcement may affect sensitivity to delay differentially. Pigeons' responses were reinforced with food, a reinforcer that is consumable upon presentation. Humans' responses were reinforced with money, a reinforcer exchanged for consumable reinforcers after it was earned. Reinforcers that are immediately consumed may generate high sensitivity to delay and behavior described as delay reduction. Reinforces with longer times to consumption may generate low sensitivity to delay and behavior that maximizes overall payoff.
Radiation dose-reduction strategies in thoracic CT.
Moser, J B; Sheard, S L; Edyvean, S; Vlahos, I
2017-05-01
Modern computed tomography (CT) machines have the capability to perform thoracic CT for a range of clinical indications at increasingly low radiation doses. This article reviews several factors, both technical and patient-related, that can affect radiation dose and discusses current dose-reduction methods relevant to thoracic imaging through a review of current techniques in CT acquisition and image reconstruction. The fine balance between low radiation dose and high image quality is considered throughout, with an emphasis on obtaining diagnostic quality imaging at the lowest achievable radiation dose. The risks of excessive radiation dose reduction are also considered. Inappropriately low dose may result in suboptimal or non-diagnostic imaging that may reduce diagnostic confidence, impair diagnosis, or result in repeat examinations incurring incremental ionising radiation exposure. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Harris, Andrew C.; Pentel, Paul R.; LeSage, Mark G.
2013-01-01
Rationale The ability of tobacco harm reduction strategies to produce significant reductions in toxin exposure is limited by compensatory increases in smoking behavior. Characterizing factors contributing to the marked individual variability in compensation may be useful for understanding this phenomenon and assessing the feasibility of harm reduction interventions. Objective To use an animal model of human compensatory smoking that involves a decrease in unit dose supporting nicotine self-administration (NSA) to examine potential contributors to individual differences in compensation. Methods Rats were trained for NSA during daily 23 hr sessions at a unit dose of 0.06 mg/kg/inf until responding was stable. The unit dose was then reduced to 0.03 mg/kg/inf for at least 10 sessions. Following reacquisition of NSA at the training dose and extinction, single-dose nicotine pharmacokinetic parameters were determined. Results Decreases in nicotine intake following dose reduction were proportionally less than the decrease in unit dose, indicating partial compensation. Compensatory increases in infusion rates were observed across the course of the 23 hr sessions. The magnitude of compensation differed considerably between rats. Rats exhibiting the highest baseline infusion rates exhibited the lowest levels of compensation. Nicotine pharmacokinetic parameters were not significantly correlated with compensation. Infusion rates immediately returned to pre-reduction levels when baseline conditions were restored. Conclusions These findings provide initial insights into correlates of individual differences in compensation following a reduction in nicotine unit dose. The present assay may be useful for characterizing mechanisms and potential consequences of the marked individual differences in compensatory smoking observed in humans. PMID:19475400
Zeng, Yaohui; Singh, Sachinkumar; Wang, Kai
2017-01-01
Abstract Pharmacodynamic studies that use methacholine challenge to assess bioequivalence of generic and innovator albuterol formulations are generally designed per published Food and Drug Administration guidance, with 3 reference doses and 1 test dose (3‐by‐1 design). These studies are challenging and expensive to conduct, typically requiring large sample sizes. We proposed 14 modified study designs as alternatives to the Food and Drug Administration–recommended 3‐by‐1 design, hypothesizing that adding reference and/or test doses would reduce sample size and cost. We used Monte Carlo simulation to estimate sample size. Simulation inputs were selected based on published studies and our own experience with this type of trial. We also estimated effects of these modified study designs on study cost. Most of these altered designs reduced sample size and cost relative to the 3‐by‐1 design, some decreasing cost by more than 40%. The most effective single study dose to add was 180 μg of test formulation, which resulted in an estimated 30% relative cost reduction. Adding a single test dose of 90 μg was less effective, producing only a 13% cost reduction. Adding a lone reference dose of either 180, 270, or 360 μg yielded little benefit (less than 10% cost reduction), whereas adding 720 μg resulted in a 19% cost reduction. Of the 14 study design modifications we evaluated, the most effective was addition of both a 90‐μg test dose and a 720‐μg reference dose (42% cost reduction). Combining a 180‐μg test dose and a 720‐μg reference dose produced an estimated 36% cost reduction. PMID:29281130
Captopril in hypertension after renal transplantation.
Chan, M. K.; Sweny, P.; El Nahas, A. M.; Farrington, K.; Fernando, O. N.; Moorhead, J. F.
1984-01-01
Eight hypertensive renal allograft recipients who had received captopril are presented. Captopril in a maximal daily dose of 250 mg enabled the withdrawal of large doses of beta-blocking agents and vasodilators. Blood pressure was satisfactorily controlled in all except one. No adverse side effects were observed other than the 'first dose' effect which resulted in transient anuria in one patient. Captopril appears to be a useful agent in the management of severe hypertension after renal transplantation. PMID:6369287
Puthon, Lara; Bouzat, Pierre; Robach, Paul; Favre-Juvin, Anne; Doutreleau, Stéphane; Verges, Samuel
2017-04-01
What is the central question of this study? This study aimed to determine the effect of ageing on cardiorespiratory and tissue oxygenation responses to hypoxia during maximal incremental exercise. What is the main finding and its importance? Older healthy subjects had preserved hypoxic cardiorespiratory and tissue oxygenation responses at rest and during moderate exercise. At maximal exercise, they had a reduced hypoxic ventilatory response but similar maximal power output reduction compared with young individuals. This study suggests that until moderate exercise, hypoxic responses are preserved until the age of 70 years and therefore that ageing is not a contraindication for high-altitude sojourn. This study assessed the effects of ageing on cardiorespiratory and tissue oxygenation responses to hypoxia both at rest and during incremental maximal exercise. Sixteen young (20-30 years old) and 15 older healthy subjects (60-70 years old) performed two maximal incremental cycling tests in normoxia and hypoxia (inspiratory oxygen fraction 12%). Cardiorespiratory responses, prefrontal cortex and quadriceps tissue oxygenation (near-infrared spectroscopy) were measured during exercise as well as during hypercapnia at rest. The hypoxic ventilatory response was similar in young compared with older individuals at rest and during moderate-intensity exercise (50% maximal power output: young 0.9 ± 0.2 versus older 1.1 ± 0.8 l min -1 % -1 ; P > 0.05) but larger in young subjects during high-intensity exercise (maximal power output: 2.2 ± 0.8 versus 1.8 ± 1.1 l min -1 % -1 ; P < 0.05). The hypoxic cardiac response did not differ between groups both at rest and during exercise. During exercise in hypoxia, young subjects showed greater deoxygenation than older subjects, at both the prefrontal cortex and quadriceps levels. The hypoxia-induced reduction in maximal power output (young -32 ± 5% versus older -30 ± 6%; P > 0.05) and the hypercapnic responses did not differ between groups. Older healthy and active individuals below the age of 70 years have cardiorespiratory and tissue oxygenation responses to hypoxia similar to young individuals both at rest and during moderate-intensity exercise. Despite a lower hypoxic ventilatory response at maximal exercise, older individuals have similar oxygen desaturation and maximal power output reduction compared with young subjects. © 2017 The Authors. Experimental Physiology © 2017 The Physiological Society.
Kim, Soo Hyun; Jung, Seung Eun; Oh, Sang Hoon; Park, Kyu Nam; Youn, Chun Song
2011-11-03
Severely injured trauma patients are exposed to clinically significant radiation doses from computed tomography (CT) imaging in the emergency department. Moreover, this radiation exposure is associated with an increased risk of cancer. The purpose of this study was to determine some effects of a radiation dose reduction strategy for CT in severely injured trauma patients in the emergency department. We implemented the radiation dose reduction strategy in May 2009. A prospective observational study design was used to collect data from patients who met the inclusion criteria during this one year study (intervention group) from May 2009 to April 2010. The prospective data were compared with data collected retrospectively for one year prior to the implementation of the radiation dose reduction strategy (control group). By comparison of the cumulative effective dose and the number of CT examinations in the two groups, we evaluated effects of a radiation dose reduction strategy. All the patients met the institutional adult trauma team activation criteria. The radiation doses calculated by the CT scanner were converted to effective doses by multiplication by a conversion coefficient. A total of 118 patients were included in this study. Among them, 33 were admitted before May 2009 (control group), and 85 were admitted after May 2009 (intervention group). There were no significant differences between the two groups regarding baseline characteristics, such as injury severity and mortality. Additionally, there was no difference between the two groups in the mean number of total CT examinations per patient (4.8 vs. 4.5, respectively; p = 0.227). However, the mean effective dose of the total CT examinations per patient significantly decreased from 78.71 mSv to 29.50 mSv (p < 0.001). The radiation dose reduction strategy for CT in severely injured trauma patients effectively decreased the cumulative effective dose of the total CT examinations in the emergency department. But not effectively decreased the number of CT examinations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Trimor, P.
The Environmental Protection Agency (EPA) requires the use of the computer model CAP88-PC to estimate the total effective doses (TED) for demonstrating compliance with 40 CFR 61, Subpart H (EPA 2006), the National Emission Standards for Hazardous Air Pollutants (NESHAP) regulations. As such, CAP88 Version 4.0 was used to calculate the receptor dose due to routine atmospheric releases at the Savannah River Site (SRS). For estimation, NESHAP dose-release factors (DRFs) have been supplied to Environmental Compliance and Area Closure Projects (EC&ACP) for many years. DRFs represent the dose to a maximum receptor exposed to 1 Ci of a specified radionuclidemore » being released into the atmosphere. They are periodically updated to include changes in the CAP88 version, input parameter values, site meteorology, and location of the maximally exposed individual (MEI). This report presents the DRFs of tritium oxide released at two onsite locations, center-of-site (COS) and H-Area, at 0 ft. elevation to maximally exposed individuals (MEIs) located 1000, 3000, 6000, 9000, and 12000 meters from the release areas for 16 compass sectors. The analysis makes use of area-specific meteorological data (Viner 2014).« less
Takahashi, Fumihiro; Morita, Satoshi
2018-02-08
Phase II clinical trials are conducted to determine the optimal dose of the study drug for use in Phase III clinical trials while also balancing efficacy and safety. In conducting these trials, it may be important to consider subpopulations of patients grouped by background factors such as drug metabolism and kidney and liver function. Determining the optimal dose, as well as maximizing the effectiveness of the study drug by analyzing patient subpopulations, requires a complex decision-making process. In extreme cases, drug development has to be terminated due to inadequate efficacy or severe toxicity. Such a decision may be based on a particular subpopulation. We propose a Bayesian utility approach (BUART) to randomized Phase II clinical trials which uses a first-order bivariate normal dynamic linear model for efficacy and safety in order to determine the optimal dose and study population in a subsequent Phase III clinical trial. We carried out a simulation study under a wide range of clinical scenarios to evaluate the performance of the proposed method in comparison with a conventional method separately analyzing efficacy and safety in each patient population. The proposed method showed more favorable operating characteristics in determining the optimal population and dose.
NASA Astrophysics Data System (ADS)
Morgan, Ashraf
The need for an accurate and reliable way for measuring patient dose in multi-row detector computed tomography (MDCT) has increased significantly. This research was focusing on the possibility of measuring CT dose in air to estimate Computed Tomography Dose Index (CTDI) for routine quality control purposes. New elliptic CTDI phantom that better represent human geometry was manufactured for investigating the effect of the subject shape on measured CTDI. Monte Carlo simulation was utilized in order to determine the dose distribution in comparison to the traditional cylindrical CTDI phantom. This research also investigated the effect of Siemens health care newly developed iMAR (iterative metal artifact reduction) algorithm, arthroplasty phantom was designed and manufactured that purpose. The design of new phantoms was part of the research as they mimic the human geometry more than the existing CTDI phantom. The standard CTDI phantom is a right cylinder that does not adequately represent the geometry of the majority of the patient population. Any dose reduction algorithm that is used during patient scan will not be utilized when scanning the CTDI phantom, so a better-designed phantom will allow the use of dose reduction algorithms when measuring dose, which leads to better dose estimation and/or better understanding of dose delivery. Doses from a standard CTDI phantom and the newly-designed phantoms were compared to doses measured in air. Iterative reconstruction is a promising technique in MDCT dose reduction and artifacts correction. Iterative reconstruction algorithms have been developed to address specific imaging tasks as is the case with Iterative Metal Artifact Reduction or iMAR which was developed by Siemens and is to be in use with the companys future computed tomography platform. The goal of iMAR is to reduce metal artifact when imaging patients with metal implants and recover CT number of tissues adjacent to the implant. This research evaluated iMAR capability of recovering CT numbers and reducing noise. Also, the use of iMAR should allow using lower tube voltage instead of 140 KVp which is used frequently to image patients with shoulder implants. The evaluations of image quality and dose reduction were carried out using an arthroplasty phantom.
Landes, Reid D.; Lensing, Shelly Y.; Kodell, Ralph L.; Hauer-Jensen, Martin
2014-01-01
The dose of a substance that causes death in P% of a population is called an LDP, where LD stands for lethal dose. In radiation research, a common LDP of interest is the radiation dose that kills 50% of the population by a specified time, i.e., lethal dose 50 or LD50. When comparing LD50 between two populations, relative potency is the parameter of interest. In radiation research, this is commonly known as the dose reduction factor (DRF). Unfortunately, statistical inference on dose reduction factor is seldom reported. We illustrate how to calculate confidence intervals for dose reduction factor, which may then be used for statistical inference. Further, most dose reduction factor experiments use hundreds, rather than tens of animals. Through better dosing strategies and the use of a recently available sample size formula, we also show how animal numbers may be reduced while maintaining high statistical power. The illustrations center on realistic examples comparing LD50 values between a radiation countermeasure group and a radiation-only control. We also provide easy-to-use spreadsheets for sample size calculations and confidence interval calculations, as well as SAS® and R code for the latter. PMID:24164553
Adequate margins for random setup uncertainties in head-and-neck IMRT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Astreinidou, Eleftheria; Bel, Arjan; Raaijmakers, Cornelis P.J.
2005-03-01
Purpose: To investigate the effect of random setup uncertainties on the highly conformal dose distributions produced by intensity-modulated radiotherapy (IMRT) for clinical head-and-neck cancer patients and to determine adequate margins to account for those uncertainties. Methods and materials: We have implemented in our clinical treatment planning system the possibility of simulating normally distributed patient setup displacements, translations, and rotations. The planning CT data of 8 patients with Stage T1-T3N0M0 oropharyngeal cancer were used. The clinical target volumes of the primary tumor (CTV{sub primary}) and of the lymph nodes (CTV{sub elective}) were expanded by 0.0, 1.5, 3.0, and 5.0 mm inmore » all directions, creating the planning target volumes (PTVs). We performed IMRT dose calculation using our class solution for each PTV margin, resulting in the conventional static plans. Then, the system recalculated the plan for each positioning displacement derived from a normal distribution with {sigma} = 2 mm and {sigma} = 4 mm (standard deviation) for translational deviations and {sigma} = 1 deg for rotational deviations. The dose distributions of the 30 fractions were summed, resulting in the actual plan. The CTV dose coverage of the actual plans was compared with that of the static plans. Results: Random translational deviations of {sigma} = 2 mm and rotational deviations of {sigma} = 1 deg did not affect the CTV{sub primary} volume receiving 95% of the prescribed dose (V{sub 95}) regardless of the PTV margin used. A V{sub 95} reduction of 3% and 1% for a 0.0-mm and 1.5-mm PTV margin, respectively, was observed for {sigma} = 4 mm. The V{sub 95} of the CTV{sub elective} contralateral was approximately 1% and 5% lower than that of the static plan for {sigma} = 2 mm and {sigma} = 4 mm, respectively, and for PTV margins < 5.0 mm. An additional reduction of 1% was observed when rotational deviations were included. The same effect was observed for the CTV{sub elective} ipsilateral but with smaller dose differences than those for the contralateral side. The effect of the random uncertainties on the mean dose to the parotid glands was not significant. The maximal dose to the spinal cord increased by a maximum of 3 Gy. Conclusions: The margins to account for random setup uncertainties, in our clinical IMRT solution, should be 1.5 mm and 3.0 mm in the case of {sigma} = 2 mm and {sigma} = 4 mm, respectively, for the CTV{sub primary}. Larger margins (5.0 mm), however, should be applied to the CTV{sub elective}, if the goal of treatment is a V{sub 95} value of at least 99%.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, J; Followill, D; Howell, R
2015-06-15
Purpose: To investigate two strategies for reducing dose calculation errors near metal implants: use of CT metal artifact reduction methods and implementation of metal-based energy deposition kernels in the convolution/superposition (C/S) method. Methods: Radiochromic film was used to measure the dose upstream and downstream of titanium and Cerrobend implants. To assess the dosimetric impact of metal artifact reduction methods, dose calculations were performed using baseline, uncorrected images and metal artifact reduction Methods: Philips O-MAR, GE’s monochromatic gemstone spectral imaging (GSI) using dual-energy CT, and GSI imaging with metal artifact reduction software applied (MARs).To assess the impact of metal kernels, titaniummore » and silver kernels were implemented into a commercial collapsed cone C/S algorithm. Results: The CT artifact reduction methods were more successful for titanium than Cerrobend. Interestingly, for beams traversing the metal implant, we found that errors in the dimensions of the metal in the CT images were more important for dose calculation accuracy than reduction of imaging artifacts. The MARs algorithm caused a distortion in the shape of the titanium implant that substantially worsened the calculation accuracy. In comparison to water kernel dose calculations, metal kernels resulted in better modeling of the increased backscatter dose at the upstream interface but decreased accuracy directly downstream of the metal. We also found that the success of metal kernels was dependent on dose grid size, with smaller calculation voxels giving better accuracy. Conclusion: Our study yielded mixed results, with neither the metal artifact reduction methods nor the metal kernels being globally effective at improving dose calculation accuracy. However, some successes were observed. The MARs algorithm decreased errors downstream of Cerrobend by a factor of two, and metal kernels resulted in more accurate backscatter dose upstream of metals. Thus, these two strategies do have the potential to improve accuracy for patients with metal implants in certain scenarios. This work was supported by Public Health Service grants CA 180803 and CA 10953 awarded by the National Cancer Institute, United States of Health and Human Services, and in part by Mobius Medical Systems.« less
Weber, Damien C; Bogner, Joachim; Verwey, Jorn; Georg, Dietmar; Dieckmann, Karin; Escudé, Lluis; Caro, Monica; Pötter, Richard; Goitein, Gudrun; Lomax, Antony J; Miralbell, Raymond
2005-10-01
A comparative treatment planning study was undertaken between proton and photon therapy in uveal melanoma to assess the potential benefits and limitations of these treatment modalities. A fixed proton horizontal beam (OPTIS) and intensity-modulated spot-scanning proton therapy (IMPT), with multiple noncoplanar beam arrangements, was compared with linear accelerator-based stereotactic radiotherapy (SRT), using a static and a dynamic micromultileaf collimator and intensity-modulated RT (IMRS). A planning CT scan was performed on a brain metastasis patient, with a 3-mm acquisition slice spacing and the patient looking at a luminous spot with the eyes in three different positions (neutral and 25 degrees right and left). Four different gross tumor volumes were defined for each treatment technique. These target scenarios represented different locations (involving vs. not involving the macula and temporal vs. nasal) and volumes (10 x 6 mm vs. 16 x 10 mm) to challenge the proton and photon treatment techniques. The planning target volume was defined as the gross tumor volume plus 2 mm laterally and 3 mm craniocaudally for both modalities. A dose homogeneity of 95-99% of the planning target volume was used as the "goal" for all techniques. The dose constraint (maximum) for the organs at risk (OARs) for both the proton and the SRT photon plans was 27.5, 22.5, 20, and 9 CGE-Gy for the optic apparatus, retina, lacrimal gland, and lens, respectively. The dose to the planning target volume was 50 CGE-Gy in 10 CGE-Gy daily fractions. The plans for proton and photon therapy were computed using the Paul Scherrer Institute and BrainSCAN, version 5.2 (BrainLAB, Heimstetten, Germany) treatment planning systems, respectively. Tumor and OARs dose-volume histograms were calculated. The results were analyzed using the dose-volume histogram parameters, conformity index (CI(95%)), and inhomogeneity coefficient. Target coverage of all simulated uveal melanomas was equally conformal with the photon and proton modalities. The median CI(95%) value was 1.74, 1.86, and 1.83 for the static, dynamic, and IMSRT plans, respectively. With proton planning, the median CI(95%) was 1.88 for OPTIS and substantially improved with IMPT in some tumor cases (median CI(95%), 1.29). The tumor dose homogeneity in the proton plans was, however, always better than with SRT photon planning (median inhomogeneity coefficient 0.1 and 0.15 vs. 0.46, 0.41, and 0.23 for the OPTIS and IMPT vs. the static, dynamic, and IMSRT plans, respectively). Compared with the photon plans, the use of protons did not lead to a substantial reduction in the homolateral OAR total integral dose in the low- to high-dose level, except for the lacrimal gland. The median maximal dose and dose at the 10% volume with the static, dynamic, and IMSRT plans was 33-30.8, 31.8-28, and 35.8-49 Gy, respectively, for the lacrimal gland, a critical organ. For protons, only the OPTIS plans were better, with a median maximal dose and dose at the 10% volume using OPTIS and IMPT of 19.2 and 8.8 and 25.6 and 23.6 CGE, respectively. The contralateral OARs were completely spared with the proton plans, but the median dose delivered to these structures was 1.2 Gy (range, 0-6.3 Gy) with the SRT photon plans. These results suggest that the use of SRT photon techniques, compared with protons, can result in similar levels of dose conformation. IMPT did not increase the degree of conformality for this small tumor. Tumor dose inhomogeneity was, however, always increased with photon planning. Except for the lacrimal gland, the use of protons, with or without intensity modulation, did not increase homolateral OAR dose sparing. The dose to all the contralateral OARs was, however, completely eliminated with proton planning.
Savic, RM; MacKenzie, WR; Engle, M; Whitworth, WC; Johnson, JL; Nsubuga, P; Nahid, P; Nguyen, NV; Peloquin, CA; Dooley, KE; Dorman, SE
2017-01-01
Rifapentine is a highly active antituberculosis antibiotic with treatment‐shortening potential; however, exposure–response relations and the dose needed for maximal bactericidal activity have not been established. We used pharmacokinetic/pharmacodynamic data from 657 adults with pulmonary tuberculosis participating in treatment trials to compare rifapentine (n = 405) with rifampin (n = 252) as part of intensive‐phase therapy. Population pharmacokinetic/pharmacodynamic analyses were performed with nonlinear mixed‐effects modeling. Time to stable culture conversion of sputum to negative was determined in cultures obtained over 4 months of therapy. Rifapentine exposures were lower in participants who were coinfected with human immunodeficiency virus, black, male, or fasting when taking drug. Rifapentine exposure, large lung cavity size, and geographic region were independently associated with time to culture conversion in liquid media. Maximal treatment efficacy is likely achieved with rifapentine at 1,200 mg daily. Patients with large lung cavities appear less responsive to treatment, even at high rifapentine doses. PMID:28124478
Song, Yanbo; Zhang, Miao; Gan, Lu; Chen, Xiaopin; Zhang, Tao; Yue, Ning J; Goyal, Sharad; Haffty, Bruce; Ren, Guosheng
2016-05-31
Electronic tissue compensation (eComp) is an external beam planning technique allowing user to manually generate dynamic beam fluence to produce more uniform or modulated dose distribution. In this study, we compared the effectiveness between conventional three-dimensional conformal radiotherapy (3DCRT) and eComp for whole breast irradiation. 3DCRT and eComp planning techniques were used to generate treatment plans for 60 whole breast patients, respectively. The planning goal was to cover 95% of the planning target volume (PTV) with 95% of the prescription dose while minimizing doses to lung, heart, and skin. Comparing to 3DCRT plans, on the average, eComp treatment planning process was about 7 minutes longer, but resulted in lower lung V20Gy, lower mean skin dose, with similar heart dose. The benefits were more pronounced for larger breast patients. Statistical analyses were performed between critical organ doses and patient anatomic features, i.e., central lung distance (CLD), maximal heart distance (MHD), maximal heart length (MHL) and breast separation (BS) to explore any correlations and planning method selection. It was found that to keep the lung V20Gy lower than 20% and mean skin dose lower than 85% of the prescription dose, eComp was the preferred method for patients with more than 2.3 cm CLD or larger than 22.5 cm BS. The study results may be useful in providing a handy criterion in clinical practice allowing us to easily choose between different planning techniques to satisfy the planning goal with minimal increase in complexity and cost.
Smith, Daniel L.; Robertson, Henry; Desmond, Renee; Nagy, Tim R.; Allison, David B.
2010-01-01
Objective The health and longevity effects of body weight reduction resulting from exercise and caloric restriction in rodents are well known, but less is known about whether similar effects occur with weight reduction from the use of a pharmaceutical agent such as sibutramine, a serotonin-norepinephrine reuptake inhibitor. Results & Conclusion Using data from a two-year toxicology study of sibutramine in CD rats and CD-1 mice, despite a dose-dependent reduction in food intake and body weight in rats compared to controls, and a body weight reduction in mice at the highest dose, there was no compelling evidence for reductions in mortality rate. PMID:21079617
Kimoto, Aishi; Tanaka, Makoto; Nozaki, Kazutoshi; Mori, Masamichi; Fukushima, Shinji; Mori, Hiroshi; Shiroya, Tsutomu; Nakamura, Toshitaka
2013-07-01
This study examined and compared the effects of four-week intermittent and daily administrations of minodronic acid, a highly potent nitrogen-containing bisphosphonate, on bone mineral density (BMD), bone strength, bone turnover, and histomorphometry on established osteopenia in ovariectomized (OVX) rats. Fourteen-week-old female F344 rats were OVX or sham-operated. At 12 weeks post surgery, minodronic acid was orally administered once every 4 weeks at 0.2, 1, and 5 mg/kg and once daily at 0.006, 0.03, and 0.15 mg/kg for 12 months. The total dosing amount was comparable between the two dosing regimens. The levels of urinary deoxypyridinoline and serum osteocalcin were measured to assess bone turnover. BMD as assessed via dual-energy X-ray absorptiometry, bone structure and dynamical changes in vertebral trabecula and biomechanical properties were measured ex vivo at 12 months to assess bone content and material properties. Minodronic acid dose-dependently ameliorated the decrease in BMD of lumbar vertebrae and the femur in both treatment regimens similarly. Minodronic acid suppressed elevated urinary levels of deoxypyridinoline, a bone resorption marker, and reduced the serum levels of osteocalcin, a bone formation marker. In the mechanical test at 12 months of treatment, minodronic acid dose-dependently ameliorated the reduction in bone strength in femur and vertebral body. There is no significant difference in parameters between the two regimens except maximal load of lower doses in lumbar vertebral body and absorption energy of middle doses in femur. With these parameters with significant differences, values of the intermittent regimen were significantly lower than that of daily repeated regimen. Bone histomorphometric analysis of the lumbar vertebral body showed that minodronic acid significantly ameliorated the decrease in bone mass, trabecular thickness and number, and the increase in trabecular separation, bone resorption indices (Oc.S/BS and N.Oc/BS), and bone formation indices (BFR/BS, MAR and OV/BV) in both regimens. Minodronic acid suppressed OVX-induced increases in bone turnover at the tissue level and ameliorated all structural indices, thereby improving the deterioration of bone quality under osteoporotic disease conditions regardless of the regimen. In conclusion, a four-week intermittent treatment of minodronic acid suppressed increased bone resorption as daily treatment when considering the total administered dose in OVX rats with established osteopenia. The improvement of microarchitectural destruction in low dose of intermittent treatment was weaker than that observed in a daily repeated regimen; however the effects of high and middle doses of intermittent treatment were equivalent to that observed in daily repeated regimen accompanied by sufficient bone resorption inhibition in rats. These findings suggest that minodronic acid at an appropriate dose in an intermittent regimen may be as clinically useful in osteoporosis therapy as in daily treatment. Copyright © 2013 Elsevier Inc. All rights reserved.
Rao, Gauri G; Ly, Neang S; Haas, Curtis E; Garonzik, Samira; Forrest, Alan; Bulitta, Jurgen B; Kelchlin, Pamela A; Holden, Patricia N; Nation, Roger L; Li, Jian; Tsuji, Brian T
2014-01-01
Increasing evidence suggests that colistin monotherapy is suboptimal at currently recommended doses. We hypothesized that front-loading provides an improved dosing strategy for polymyxin antibiotics to maximize killing and minimize total exposure. Here, we utilized an in vitro pharmacodynamic model to examine the impact of front-loaded colistin regimens against a high bacterial density (10(8) CFU/ml) of Pseudomonas aeruginosa. The pharmacokinetics were simulated for patients with hepatic (half-life [t1/2] of 3.2 h) or renal (t1/2 of 14.8 h) disease. Front-loaded regimens (n=5) demonstrated improvement in bacterial killing, with reduced overall free drug areas under the concentration-time curve (fAUC) compared to those with traditional dosing regimens (n=14) with various dosing frequencies (every 12 h [q12h] and q24h). In the renal failure simulations, front-loaded regimens at lower exposures (fAUC of 143 mg · h/liter) obtained killing activity similar to that of traditional regimens (fAUC of 268 mg · h/liter), with an ∼97% reduction in the area under the viable count curve over 48 h. In hepatic failure simulations, front-loaded regimens yielded rapid initial killing by up to 7 log10 within 2 h, but considerable regrowth occurred for both front-loaded and traditional regimens. No regimen eradicated the high bacterial inoculum of P. aeruginosa. The current study, which utilizes an in vitro pharmacodynamic infection model, demonstrates the potential benefits of front-loading strategies for polymyxins simulating differential pharmacokinetics in patients with hepatic and renal failure at a range of doses. Our findings may have important clinical implications, as front-loading polymyxins as a part of a combination regimen may be a viable strategy for aggressive treatment of high-bacterial-burden infections.
Oxytocin Reduces Ethanol Self-Administration in Mice
King, Courtney E.; Griffin, William C.; Luderman, Lauryn N.; Kates, Malcolm M.; McGinty, Jacqueline F.; Becker, Howard C.
2017-01-01
Background Excessive ethanol consumption remains an important health concern and effective treatments are lacking. The central oxytocin system has emerged as a potentially important therapeutic target for alcohol and drug addiction. These studies tested the hypothesis that oxytocin reduces ethanol consumption. Methods Male C57BL/6J mice were given access to ethanol (20% v/v) using a model of binge-like drinking (“drinking-in-the-dark”) that also included the use of lickometer circuits to evaluate the temporal pattern of intake as well as 2-bottle choice drinking in the home cage. In addition, ethanol (12% v/v) and sucrose (5% w/v) self-administration on fixed- and progressive- ratio schedules were also evaluated. A wide range of systemically administered oxytocin doses were tested (0 to 10 mg/kg) in these models. Results Oxytocin (0, 0.3, 1, 3 or 10mg/kg) dose-dependently reduced ethanol consumption (maximal 45% reducton) in the binge drinking model, with lower effective doses having minimal effects on general locomotor activity. Oxytocin’s effect was blocked by pretreatment with an oxytocin receptor antagonist and the pattern of contacts (licks) at the ethanol bottle suggested a reduction in motivation to drink ethanol. Oxytocin decreased 2-bottle choice drinking without altering general fluid intake. Oxytocin also reduced operant responding for ethanol and sucrose in a dose-related manner. However, oxytocin decreased responding and motivation (breakpoint values) for ethanol at doses that did not alter responding for sucrose. Discussion These results indicate that oxytocin reduces ethanol consumption in different models of self-administration. The effects are not likely due to a general sedative effect of the neuropeptide. Further, oxytocin reduces motivation for ethanol at doses that do not alter responding for a natural reward (sucrose). While some evidence supports a role for oxytocin receptors in mediating these effects, additional studies are needed to further elucidate underlying mechanisms. Neverthess, these results support the therapeutic potential of oxytocin as a treatment for alcohol use disorder. PMID:28212464
[High-dose Crataegus extract WS 1442 in the treatment of NYHA stage II heart failure].
Tauchert, M; Gildor, A; Lipinski, J
1999-10-01
The efficacy and tolerance of the standardized hawthorn (crataegus) extract WS 1442 were tested in a multicenter utilization observational study. We monitored 1,011 patients with cardiac insufficiency stage NYHA II, treated with this extract (Crataegutt novo 450, 1 tablet b.i.d.) over a period of 24 weeks. During and at the end of the observation period a significant improvement in clinical symptoms (reduced performance in the exercise tolerance test, fatigue, palpitation and exercise dyspnea) was observed. Ankle edema and nocturia disappeared by 83%, and by half of the patients respectively manifesting these symptoms before treatment. The improvement and economization of cardiac performance were additionally shown by a reduction in blood pressure, an increased maximal exercise tolerance and a reduction in the difference in the pressure/heart rate product (PHRP). The positive effects of WS 1442 were further demonstrated by an improved ejection fraction and an increased percentile shortening fraction measured using M-mode echocardiography. The stabilizing effect of the hawthorn extract on the heart rate was shown by a slower rest pulse, as well as by an increase in the number of day and night normorhythmic patients, as documented by long-term ECG. The reduction in the number of patients showing ST depressions, arrhythmias and ventricular extrasystoles at the maximum exercise level is regarded as an indication for an improved myocardial perfusion. Fourteen side effects were noted. In two cases (abdominal discomfort and facial pains accompanied by tachycardia) a possible relationship with the hawthorn therapy, was postulated which however was considered unlikely by the treating physicians. Almost 2/3 of the patients felt better or much better following the 24 weeks of treatment. More than 3/4 of the participating physicians noted a good or a very good efficacy, and 98.7% noted a good or a very good tolerance. High-dose hawthorn therapy is an efficient, well-tolerated and easily regulated therapeutic alternative for patients suffering from cardiac insufficiency stage NYHA II.
Sabra, R; Zeinoun, N; Sharaf, L H; Ghali, R; Beshara, G; Serhal, H
2001-04-01
The mechanisms responsible for amphotericin B nephrotoxicity remain incompletely understood, but clearly involve reduction in renal blood flow and glomerular filtration rate. Both direct effects of amphotericin B on contractile vascular cells, and indirect effects, due to humoural mediators, have been proposed. This study examines the role of nitric oxide, endothelin and angiotensin II in the acute nephrotoxic effects of amphotericin B in rats, and compares the anti-fungal and nephrotoxic effects of liposomal amphotericin B and amphotericin B-deoxycholate. Anaesthetized rats were given infusions of amphotericin B-deoxycholate in the presence or absence of N-nitro-L-arginine, PD 145065, a non-specific endothelin receptor antagonist, and L-158809, an angiotensin II type I receptor antagonist, or increasing doses of liposomal amphotericin B. Amphotericin B-deoxycholate (0.03 mg/kg/min intravenously) caused a significant 44% reduction in glomerular filtration rate and 65% maximal fall in renal blood flow. N-Nitro-L-arginine-treated rats had a lower renal blood flow and glomerular filtration rate at baseline, but sustained similar reduction of 53% and 75% in these parameters, respectively. PD145065 and L-158809 did not modify these effects either. Increasing doses of liposomal amphotericin B (from 0.01 up to 0.50 mg/kg/min.) induced no change in either glomerular filtration rate or renal blood flow. In vitro susceptibility tests revealed similar potency for liposomal amphotericin B and amphotericin B-deoxycholate in their fungistatic effects and slightly higher potency for amphotericin B-deoxycholate in their fungicidal effect. These results suggest that endogenous endothelin, angiotensin II or nitric oxide systems are not involved in the nephrotoxic effects of amphotericin B. The liposomal amphotericin B results suggest that amphotericin B nephrotoxicity is due to a direct interaction of amphotericin B with renal cells that is prevented by its encapsulation in liposomes.
SU-C-207B-02: Maximal Noise Reduction Filter with Anatomical Structures Preservation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maitree, R; Guzman, G; Chundury, A
Purpose: All medical images contain noise, which can result in an undesirable appearance and can reduce the visibility of anatomical details. There are varieties of techniques utilized to reduce noise such as increasing the image acquisition time and using post-processing noise reduction algorithms. However, these techniques are increasing the imaging time and cost or reducing tissue contrast and effective spatial resolution which are useful diagnosis information. The three main focuses in this study are: 1) to develop a novel approach that can adaptively and maximally reduce noise while preserving valuable details of anatomical structures, 2) to evaluate the effectiveness ofmore » available noise reduction algorithms in comparison to the proposed algorithm, and 3) to demonstrate that the proposed noise reduction approach can be used clinically. Methods: To achieve a maximal noise reduction without destroying the anatomical details, the proposed approach automatically estimated the local image noise strength levels and detected the anatomical structures, i.e. tissue boundaries. Such information was used to adaptively adjust strength of the noise reduction filter. The proposed algorithm was tested on 34 repeating swine head datasets and 54 patients MRI and CT images. The performance was quantitatively evaluated by image quality metrics and manually validated for clinical usages by two radiation oncologists and one radiologist. Results: Qualitative measurements on repeated swine head images demonstrated that the proposed algorithm efficiently removed noise while preserving the structures and tissues boundaries. In comparisons, the proposed algorithm obtained competitive noise reduction performance and outperformed other filters in preserving anatomical structures. Assessments from the manual validation indicate that the proposed noise reduction algorithm is quite adequate for some clinical usages. Conclusion: According to both clinical evaluation (human expert ranking) and qualitative assessment, the proposed approach has superior noise reduction and anatomical structures preservation capabilities over existing noise removal methods. Senior Author Dr. Deshan Yang received research funding form ViewRay and Varian.« less
NASA Astrophysics Data System (ADS)
Liu, Junchi; Zarshenas, Amin; Qadir, Ammar; Wei, Zheng; Yang, Limin; Fajardo, Laurie; Suzuki, Kenji
2018-03-01
To reduce cumulative radiation exposure and lifetime risks for radiation-induced cancer from breast cancer screening, we developed a deep-learning-based supervised image-processing technique called neural network convolution (NNC) for radiation dose reduction in DBT. NNC employed patched-based neural network regression in a convolutional manner to convert lower-dose (LD) to higher-dose (HD) tomosynthesis images. We trained our NNC with quarter-dose (25% of the standard dose: 12 mAs at 32 kVp) raw projection images and corresponding "teaching" higher-dose (HD) images (200% of the standard dose: 99 mAs at 32 kVp) of a breast cadaver phantom acquired with a DBT system (Selenia Dimensions, Hologic, CA). Once trained, NNC no longer requires HD images. It converts new LD images to images that look like HD images; thus the term "virtual" HD (VHD) images. We reconstructed tomosynthesis slices on a research DBT system. To determine a dose reduction rate, we acquired 4 studies of another test phantom at 4 different radiation doses (1.35, 2.7, 4.04, and 5.39 mGy entrance dose). Structural SIMilarity (SSIM) index was used to evaluate the image quality. For testing, we collected half-dose (50% of the standard dose: 32+/-14 mAs at 33+/-5 kVp) and full-dose (standard dose: 68+/-23 mAs at 33+/-5 kvp) images of 10 clinical cases with the DBT system at University of Iowa Hospitals and Clinics. NNC converted half-dose DBT images of 10 clinical cases to VHD DBT images that were equivalent to full dose DBT images. Our cadaver phantom experiment demonstrated 79% dose reduction.
Testosterone Dose Dependently Prevents Bone and Muscle Loss in Rodents after Spinal Cord Injury
Conover, Christine F.; Beggs, Luke A.; Beck, Darren T.; Otzel, Dana M.; Balaez, Alexander; Combs, Sarah M.; Miller, Julie R.; Ye, Fan; Aguirre, J. Ignacio; Neuville, Kathleen G.; Williams, Alyssa A.; Conrad, Bryan P.; Gregory, Chris M.; Wronski, Thomas J.; Bose, Prodip K.; Borst, Stephen E.
2014-01-01
Abstract Androgen administration protects against musculoskeletal deficits in models of sex-steroid deficiency and injury/disuse. It remains unknown, however, whether testosterone prevents bone loss accompanying spinal cord injury (SCI), a condition that results in a near universal occurrence of osteoporosis. Our primary purpose was to determine whether testosterone-enanthate (TE) attenuates hindlimb bone loss in a rodent moderate/severe contusion SCI model. Forty (n=10/group), 14 week old male Sprague-Dawley rats were randomized to receive: (1) Sham surgery (T9 laminectomy), (2) moderate/severe (250 kdyne) SCI, (3) SCI+Low-dose TE (2.0 mg/week), or (4) SCI+High-dose TE (7.0 mg/week). Twenty-one days post-injury, SCI animals exhibited a 77–85% reduction in hindlimb cancellous bone volume at the distal femur (measured via μCT) and proximal tibia (measured via histomorphometry), characterized by a >70% reduction in trabecular number, 13–27% reduction in trabecular thickness, and increased trabecular separation. A 57% reduction in cancellous volumetric bone mineral density (vBMD) at the distal femur and a 20% reduction in vBMD at the femoral neck were also observed. TE dose dependently prevented hindlimb bone loss after SCI, with high-dose TE fully preserving cancellous bone structural characteristics and vBMD at all skeletal sites examined. Animals receiving SCI also exhibited a 35% reduction in hindlimb weight bearing (triceps surae) muscle mass and a 22% reduction in sublesional non-weight bearing (levator ani/bulbocavernosus [LABC]) muscle mass, and reduced prostate mass. Both TE doses fully preserved LABC mass, while only high-dose TE ameliorated hindlimb muscle losses. TE also dose dependently increased prostate mass. Our findings provide the first evidence indicating that high-dose TE fully prevents hindlimb cancellous bone loss and concomitantly ameliorates muscle loss after SCI, while low-dose TE produces much less profound musculoskeletal benefit. Testosterone-induced prostate enlargement, however, represents a potential barrier to the clinical implementation of high-dose TE as a means of preserving musculoskeletal tissue after SCI. PMID:24378197
Phase I Study of Vandetanib With Radiotherapy and Temozolomide for Newly Diagnosed Glioblastoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drappatz, Jan; Norden, Andrew D.; Division of Cancer Neurology, Department of Neurology, Brigham and Women's Hospital, Boston, MA
Purpose: Increasing evidence has suggested that angiogenesis inhibition might potentiate the effects of radiotherapy and chemotherapy in patients with glioblastoma (GBM). In addition, epidermal growth factor receptor inhibition might be of therapeutic benefit, because the epidermal growth factor receptor is upregulated in GBM and contributes to radiation resistance. We conducted a Phase I study of vandetanib, an inhibitor of vascular endothelial growth factor receptor 2 and epidermal growth factor receptor, in patients with newly diagnosed GBM combined with RT and temozolomide (TMZ). Methods and Materials: A total of 13 GBM patients were treated with vandetanib, radiotherapy, and concurrent and adjuvantmore » TMZ, using a standard '3 + 3' dose escalation. The maximal tolerated dose was defined as the dose with <1 of 6 dose-limiting toxicities during the first 12 weeks of therapy. The eligible patients were adults with newly diagnosed GBM, Karnofsky performance status of {>=}60, normal organ function, who were not taking enzyme-inducing antiepileptic drugs. Results: Of the 13 patients, 6 were treated with vandetanib at a dose of 200mg daily. Of the 6 patients, 3 developed dose-limiting toxicities within the first 12 weeks, including gastrointestinal hemorrhage and thrombocytopenia in 1 patient, neutropenia in 1 patient, and diverticulitis with gastrointestinal perforation in 1 patient. The other 7 patients were treated with 100 mg daily, with no dose-limiting toxicities observed, establishing this dose as the maximal tolerated dose combined with TMZ and RT. Conclusion: Vandetanib can be safely combined with RT and TMZ in GBM patients. A Phase II study in which patients are randomized to vandetanib 100 mg daily with RT and TMZ or RT and TMZ alone is underway.« less
Exclusion Area Radiation Release during the MIT Reactor Design Basis Accident.
1983-05-06
Concrete Wall 116 6.2 Concrete Albedo Dose 121 6.3 Steel Door Scattering Dose 124 7.1 Total Dose Results 133 A.1 Values of N /NO for Neutron -Capture...plate fuel elements arranged in x a compact hexagonal core. This core design maximizes the neutron flux in the DO2 reflector region where numerous...sec) V = Volume of the fuel (cm 3 f Ef = Macroscopic fission cross section (cm ) = Thermal neutron flux ( neutrons /cm2 - sec) = Core-averaged value Yi
An adaptive algorithm for the detection of microcalcifications in simulated low-dose mammography.
Treiber, O; Wanninger, F; Führ, H; Panzer, W; Regulla, D; Winkler, G
2003-02-21
This paper uses the task of microcalcification detection as a benchmark problem to assess the potential for dose reduction in x-ray mammography. We present the results of a newly developed algorithm for detection of microcalcifications as a case study for a typical commercial film-screen system (Kodak Min-R 2000/2190). The first part of the paper deals with the simulation of dose reduction for film-screen mammography based on a physical model of the imaging process. Use of a more sensitive film-screen system is expected to result in additional smoothing of the image. We introduce two different models of that behaviour, called moderate and strong smoothing. We then present an adaptive, model-based microcalcification detection algorithm. Comparing detection results with ground-truth images obtained under the supervision of an expert radiologist allows us to establish the soundness of the detection algorithm. We measure the performance on the dose-reduced images in order to assess the loss of information due to dose reduction. It turns out that the smoothing behaviour has a strong influence on detection rates. For moderate smoothing. a dose reduction by 25% has no serious influence on the detection results. whereas a dose reduction by 50% already entails a marked deterioration of the performance. Strong smoothing generally leads to an unacceptable loss of image quality. The test results emphasize the impact of the more sensitive film-screen system and its characteristics on the problem of assessing the potential for dose reduction in film-screen mammography. The general approach presented in the paper can be adapted to fully digital mammography.
An adaptive algorithm for the detection of microcalcifications in simulated low-dose mammography
NASA Astrophysics Data System (ADS)
Treiber, O.; Wanninger, F.; Führ, H.; Panzer, W.; Regulla, D.; Winkler, G.
2003-02-01
This paper uses the task of microcalcification detection as a benchmark problem to assess the potential for dose reduction in x-ray mammography. We present the results of a newly developed algorithm for detection of microcalcifications as a case study for a typical commercial film-screen system (Kodak Min-R 2000/2190). The first part of the paper deals with the simulation of dose reduction for film-screen mammography based on a physical model of the imaging process. Use of a more sensitive film-screen system is expected to result in additional smoothing of the image. We introduce two different models of that behaviour, called moderate and strong smoothing. We then present an adaptive, model-based microcalcification detection algorithm. Comparing detection results with ground-truth images obtained under the supervision of an expert radiologist allows us to establish the soundness of the detection algorithm. We measure the performance on the dose-reduced images in order to assess the loss of information due to dose reduction. It turns out that the smoothing behaviour has a strong influence on detection rates. For moderate smoothing, a dose reduction by 25% has no serious influence on the detection results, whereas a dose reduction by 50% already entails a marked deterioration of the performance. Strong smoothing generally leads to an unacceptable loss of image quality. The test results emphasize the impact of the more sensitive film-screen system and its characteristics on the problem of assessing the potential for dose reduction in film-screen mammography. The general approach presented in the paper can be adapted to fully digital mammography.
Noël, Peter B; Engels, Stephan; Köhler, Thomas; Muenzel, Daniela; Franz, Daniela; Rasper, Michael; Rummeny, Ernst J; Dobritz, Martin; Fingerle, Alexander A
2018-01-01
Background The explosive growth of computer tomography (CT) has led to a growing public health concern about patient and population radiation dose. A recently introduced technique for dose reduction, which can be combined with tube-current modulation, over-beam reduction, and organ-specific dose reduction, is iterative reconstruction (IR). Purpose To evaluate the quality, at different radiation dose levels, of three reconstruction algorithms for diagnostics of patients with proven liver metastases under tumor follow-up. Material and Methods A total of 40 thorax-abdomen-pelvis CT examinations acquired from 20 patients in a tumor follow-up were included. All patients were imaged using the standard-dose and a specific low-dose CT protocol. Reconstructed slices were generated by using three different reconstruction algorithms: a classical filtered back projection (FBP); a first-generation iterative noise-reduction algorithm (iDose4); and a next generation model-based IR algorithm (IMR). Results The overall detection of liver lesions tended to be higher with the IMR algorithm than with FBP or iDose4. The IMR dataset at standard dose yielded the highest overall detectability, while the low-dose FBP dataset showed the lowest detectability. For the low-dose protocols, a significantly improved detectability of the liver lesion can be reported compared to FBP or iDose 4 ( P = 0.01). The radiation dose decreased by an approximate factor of 5 between the standard-dose and the low-dose protocol. Conclusion The latest generation of IR algorithms significantly improved the diagnostic image quality and provided virtually noise-free images for ultra-low-dose CT imaging.
Analysis of esophageal-sparing treatment plans for patients with high-grade esophagitis.
Niedzielski, Joshua; Bluett, Jaques B; Williamson, Ryan T; Liao, Zhongxing; Gomez, Daniel R; Court, Laurence E
2013-07-08
We retrospectively generated IMRT plans for 14 NSCLC patients who had experienced grade 2 or 3 esophagitis (CTCAE version 3.0). We generated 11-beam and reduced esophagus dose plan types to compare changes in the volume and length of esophagus receiving doses of 50, 55, 60, 65, and 70 Gy. Changes in planning target volume (PTV) dose coverage were also compared. If necessary, plans were renormalized to restore 95% PTV coverage. The critical organ doses examined were mean lung dose, mean heart dose, and volume of spinal cord receiving 50 Gy. The effect of interfractional motion was determined by applying a three-dimensional rigid shift to the dose grid. For the esophagus plan, the mean reduction in esophagus V50, V55, V60, V65, and V70 Gy was 2.8, 4.1, 5.9, 7.3, and 9.5 cm(3), respectively, compared with the clinical plan. The mean reductions in LE50, LE55, LE60, LE65, and LE70 Gy were 2.0, 3.0, 3.8, 4.0, and 4.6 cm, respectively. The mean heart and lung dose decreased 3.0 Gy and 2.4 Gy, respectively. The mean decreases in 90% and 95% PTV coverage were 1.7 Gy and 2.8 Gy, respectively. The normalized plans' mean reduction of esophagus V50, V55, V60, V65, and V70 Gy were 1.6, 2.0, 2.9, 3.9, and 5.5 cm(3), respectively, compared with the clinical plans. The normalized plans' mean reductions in LE50, LE55, LE60, LE65, and LE70 Gy were 4.9, 5.2, 5.4, 4.9, and 4.8 cm, respectively. The mean reduction in maximum esophagus dose with simulated interfractional motion was 3.0 Gy and 1.4 Gy for the clinical plan type and the esophagus plan type, respectively. In many cases, the esophagus dose can be greatly reduced while maintaining critical structure dose constraints. PTV coverage can be restored by increasing beam output, while still obtaining a dose reduction to the esophagus and maintaining dose constraints.
Analysis of esophageal‐sparing treatment plans for patients with high‐grade esophagitis
Bluett, Jaques B.; Williamson, Ryan T.; Liao, Zhongxing; Gomez, Daniel R.; Court, Laurence E.
2013-01-01
We retrospectively generated IMRT plans for 14 NSCLC patients who had experienced grade 2 or 3 esophagitis (CTCAE version 3.0). We generated 11‐beam and reduced esophagus dose plan types to compare changes in the volume and length of esophagus receiving doses of 50, 55, 60, 65, and 70 Gy. Changes in planning target volume (PTV) dose coverage were also compared. If necessary, plans were renormalized to restore 95% PTV coverage. The critical organ doses examined were mean lung dose, mean heart dose, and volume of spinal cord receiving 50 Gy. The effect of interfractional motion was determined by applying a three‐dimensional rigid shift to the dose grid. For the esophagus plan, the mean reduction in esophagus V50, V55, V60, V65, and V70 Gy was 2.8, 4.1, 5.9, 7.3, and 9.5 cm3, respectively, compared with the clinical plan. The mean reductions in LE50, LE55, LE60, LE65, and LE70 Gy were 2.0, 3.0, 3.8, 4.0, and 4.6 cm, respectively. The mean heart and lung dose decreased 3.0 Gy and 2.4 Gy, respectively. The mean decreases in 90% and 95% PTV coverage were 1.7 Gy and 2.8 Gy, respectively. The normalized plans’ mean reduction of esophagus V50, V55, V60, V65, and V70 Gy were 1.6, 2.0, 2.9, 3.9, and 5.5 cm3, respectively, compared with the clinical plans. The normalized plans’ mean reductions in LE50, LE55, LE60, LE65, and LE70 Gy were 4.9, 5.2, 5.4, 4.9, and 4.8 cm, respectively. The mean reduction in maximum esophagus dose with simulated interfractional motion was 3.0 Gy and 1.4 Gy for the clinical plan type and the esophagus plan type, respectively. In many cases, the esophagus dose can be greatly reduced while maintaining critical structure dose constraints. PTV coverage can be restored by increasing beam output, while still obtaining a dose reduction to the esophagus and maintaining dose constraints. PACS number: 87.53 Tf PMID:23835390
Method for simulating dose reduction in digital mammography using the Anscombe transformation.
Borges, Lucas R; Oliveira, Helder C R de; Nunes, Polyana F; Bakic, Predrag R; Maidment, Andrew D A; Vieira, Marcelo A C
2016-06-01
This work proposes an accurate method for simulating dose reduction in digital mammography starting from a clinical image acquired with a standard dose. The method developed in this work consists of scaling a mammogram acquired at the standard radiation dose and adding signal-dependent noise. The algorithm accounts for specific issues relevant in digital mammography images, such as anisotropic noise, spatial variations in pixel gain, and the effect of dose reduction on the detective quantum efficiency. The scaling process takes into account the linearity of the system and the offset of the detector elements. The inserted noise is obtained by acquiring images of a flat-field phantom at the standard radiation dose and at the simulated dose. Using the Anscombe transformation, a relationship is created between the calculated noise mask and the scaled image, resulting in a clinical mammogram with the same noise and gray level characteristics as an image acquired at the lower-radiation dose. The performance of the proposed algorithm was validated using real images acquired with an anthropomorphic breast phantom at four different doses, with five exposures for each dose and 256 nonoverlapping ROIs extracted from each image and with uniform images. The authors simulated lower-dose images and compared these with the real images. The authors evaluated the similarity between the normalized noise power spectrum (NNPS) and power spectrum (PS) of simulated images and real images acquired with the same dose. The maximum relative error was less than 2.5% for every ROI. The added noise was also evaluated by measuring the local variance in the real and simulated images. The relative average error for the local variance was smaller than 1%. A new method is proposed for simulating dose reduction in clinical mammograms. In this method, the dependency between image noise and image signal is addressed using a novel application of the Anscombe transformation. NNPS, PS, and local noise metrics confirm that this method is capable of precisely simulating various dose reductions.
Tomaszewska, Ewa; Muszyński, Siemowit; Blicharski, Tomasz; Pierzynowski, Stefan G
2017-01-01
Synthetic glucocorticoids (GCs) are widely used in the variety of dosages for treatment of premature infants with chronic lung disease, respiratory distress syndrome, allergies, asthma, and other inflammatory and autoimmune conditions. Yet, adverse effects such as glucocorticoid-induced osteoporosis and growth retardation are recognized. Conversely, 2-oxoglutarate (2-Ox), a precursor of glutamine, glutamate, and collagen amino acids, exerts protective effects on bone development. Our aim was to elucidate the effect of dietary administered 2-Ox on bone loss caused by neonatal treatment with clinically relevant maximal therapeutic dexamethasone (Dex) dose. Long bones of neonatal female piglets receiving Dex, Dex+2-Ox, or untreated were examined through measurements of mechanical properties, density, mineralization, geometry, histomorphometry, and histology. Selected hormones, bone turnover, and growth markers were also analyzed. Neonatal administration of clinically relevant maximal dose of Dex alone led to over 30% decrease in bone mass and the ultimate strength (P < 0.001 for all). The length (13 and 7% for femur and humerus, respectively) and other geometrical parameters (13–45%) decreased compared to the control (P < 0.001 for all). Dex impaired bone growth and caused hormonal imbalance. Dietary 2-Ox prevented Dex influence and vast majority of assessed bone parameters were restored almost to the control level. Piglets receiving 2-Ox had heavier, denser, and stronger bones; higher levels of growth hormone and osteocalcin concentration; and preserved microarchitecture of trabecular bone compared to the Dex group. 2-Ox administered postnatally had a potential to maintain bone structure of animals simultaneously treated with maximal therapeutic doses of Dex, which, in our opinion, may open up a new opportunity in developing combined treatment for children treated with GCs. Impact statement The present study has showed, for the first time, that dietary 2-oxoglutarate (2-Ox) administered postnatally has a potential to improve/maintain bone structure of animals simultaneously treated with maximal therapeutic doses of dexamethasone (Dex). It may open the new direction in searching and developing combined treatment for children treated with glucocorticoids (GCs) since growing group of children is exposed to synthetic GCs and adverse effects such as glucocorticoid-induced osteoporosis and growth retardation are recognized. Currently proposed combined therapies have numerous side effects. Thus, this study proposed a new direction in combined therapies utilizing dietary supplementation with glutamine derivative. Impairment caused by Dex in presented long bones animal model was prevented by dietary supplementation with 2-Ox and vast majority of assessed bone parameters were restored almost to the control level. These results support previous thesis on the regulatory mechanism of nutrient utilization regulated by glutamine derivatives and enrich the nutritional science. PMID:28178857
Method for inserting noise in digital mammography to simulate reduction in radiation dose
NASA Astrophysics Data System (ADS)
Borges, Lucas R.; de Oliveira, Helder C. R.; Nunes, Polyana F.; Vieira, Marcelo A. C.
2015-03-01
The quality of clinical x-ray images is closely related to the radiation dose used in the imaging study. The general principle for selecting the radiation is ALARA ("as low as reasonably achievable"). The practical optimization, however, remains challenging. It is well known that reducing the radiation dose increases the quantum noise, which could compromise the image quality. In order to conduct studies about dose reduction in mammography, it would be necessary to acquire repeated clinical images, from the same patient, with different dose levels. However, such practice would be unethical due to radiation related risks. One solution is to simulate the effects of dose reduction in clinical images. This work proposes a new method, based on the Anscombe transformation, which simulates dose reduction in digital mammography by inserting quantum noise into clinical mammograms acquired with the standard radiation dose. Thus, it is possible to simulate different levels of radiation doses without exposing the patient to new levels of radiation. Results showed that the achieved quality of simulated images generated with our method is the same as when using other methods found in the literature, with the novelty of using the Anscombe transformation for converting signal-independent Gaussian noise into signal-dependent quantum noise.
A 1.5 T transverse magnetic field in radiotherapy of rectal cancer: Impact on the dose distribution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uilkema, Sander, E-mail: s.uilkema@nki.nl; Heide, Uulke van der; Sonke, Jan-Jakob
2015-12-15
Purpose: MRI guidance during radiotherapy has the potential to enable more accurate dose delivery, optimizing the balance between local control and treatment related toxicity. However, the presence of a permanent magnetic field influences the dose delivery, especially around air cavities. Here, electrons are able to return to the surface through which they entered the air cavity (electron return effect, ERE) locally resulting in dose hot- and cold-spots. Where RT of rectal cancer patients might benefit from MRI guidance for margin reduction, air cavities in and around the target volume are frequently present. The purpose of this research is to evaluatemore » the impact of the presence of a 1.5 T transverse magnetic field on dose delivery in patients with rectal cancer. Methods: Ten patients treated with 5 × 5 Gy RT having large changes in pelvic air content were selected out of a cohort of 33 patients. On the planning CT, a 1.5 T, 6 MV, 7-field intensity modulated radiotherapy (IMRT) plan was created. This plan was subsequently recalculated on daily CT scans. For each daily CT, the CTV V{sub 95%} and V{sub 107%} and bowel area V{sub 5Gy}, V{sub 10Gy}, V{sub 15Gy}, V{sub 20Gy}, and V{sub 25Gy} were calculated to evaluate the changes in dose distribution from fraction to fraction. For comparison, the authors repeated this procedure for the 0 T situation. To study the effect of changing air cavities separate from other anatomical changes, the authors also generated artificial air cavities in the CTV of one patient (2 and 5 cm diameter), in the high dose gradient region (2 cm), and in the low dose area (2 cm). Treatment plans were optimized without and with each simulated air cavity. For appearing and disappearing air cavities, the CTV V{sub 95%} and V{sub 107%} were evaluated. The authors also evaluated the ERE separate from attenuation changes locally around appearing gas pockets. Results: For the ten patients, at 1.5 T, the V{sub 95%} was influenced by both appearing and disappearing air, and dropped to <98% in 2 out of 50 fractions due a disappearing air cavity of 150 cm{sup 3}. V{sub 95%} differences between 0 and 1.5 T were all within 2%. The V{sub 107%} was below 1% in 46 out of 50 fractions, and increased to 3% in the remaining fractions due to appearing air of around 120 cm{sup 3}. For comparison, V{sub 107%} was <1% at 0 T for all fractions. In the bowel area, the V{sub 15Gy} varied strongest from fraction to fraction, but differences between 1.5 and 0 T were minimal with an average difference of 2.3 cm{sup 3} (SD = 18.7 cm{sup 3}, p = 0.38). For the simulated air cavities, the ERE resulted in cold-spots maximally 5% lower than prescribed and hot-spots maximally 6% higher than prescribed. Conclusions: The presence of a 1.5 T magnetic field has an impact on the dose distribution when the air content changes of within a few percent in these selected rectal cancer patients. The authors consider this influence of the transverse magnetic field on the dose distribution in IMRT for rectal cancer patients clinically acceptable.« less
SparseCT: interrupted-beam acquisition and sparse reconstruction for radiation dose reduction
NASA Astrophysics Data System (ADS)
Koesters, Thomas; Knoll, Florian; Sodickson, Aaron; Sodickson, Daniel K.; Otazo, Ricardo
2017-03-01
State-of-the-art low-dose CT methods reduce the x-ray tube current and use iterative reconstruction methods to denoise the resulting images. However, due to compromises between denoising and image quality, only moderate dose reductions up to 30-40% are accepted in clinical practice. An alternative approach is to reduce the number of x-ray projections and use compressed sensing to reconstruct the full-tube-current undersampled data. This idea was recognized in the early days of compressed sensing and proposals for CT dose reduction appeared soon afterwards. However, no practical means of undersampling has yet been demonstrated in the challenging environment of a rapidly rotating CT gantry. In this work, we propose a moving multislit collimator as a practical incoherent undersampling scheme for compressed sensing CT and evaluate its application for radiation dose reduction. The proposed collimator is composed of narrow slits and moves linearly along the slice dimension (z), to interrupt the incident beam in different slices for each x-ray tube angle (θ). The reduced projection dataset is then reconstructed using a sparse approach, where 3D image gradients are employed to enforce sparsity. The effects of the collimator slits on the beam profile were measured and represented as a continuous slice profile. SparseCT was tested using retrospective undersampling and compared against commercial current-reduction techniques on phantoms and in vivo studies. Initial results suggest that SparseCT may enable higher performance than current-reduction, particularly for high dose reduction factors.
Grégoire, Laurent; Samadi, Pershia; Graham, Julie; Bédard, Paul J; Bartoszyk, Gerd D; Di Paolo, Thérèse
2009-07-01
Dyskinesia is an important complication of treatment in Parkinson's disease (PD). Sarizotan, a 5-HT(1A) agonist with high affinity for D3 and D4 receptors was investigated on L-Dopa-induced dyskinesia (LID) in the 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP) animal model of PD. Five MPTP female cynomolgus monkeys (Macaca fascicularis) with a moderate to severe parkinsonian syndrome and LID were used. Sarizotan 0.2, 1, and 2 mg/kg administered alone did not worsen parkinsonian symptoms; there were no effect on locomotor counts or on normal behavior of the monkeys. Sarizotan 0.2, 1, and 2 mg/kg administered 30 min before a fixed dose of L-Dopa (25-30 mg/kg s.c.) + benserazide (50 mg) did not affect the antiparkinsonian response to L-Dopa. However, mean dyskinetic scores were significantly reduced with sarizotan 1 and 2 mg/kg but not at 0.2 mg/kg. Higher doses of sarizotan (4 and 8 mg/kg, administered immediately before L-Dopa) reduced L-Dopa-induced locomotor response in all monkeys. A pharmacokinetic investigation in these monkeys showed a dose-dependent increase in mean plasma sarizotan concentrations with similar mean plasma concentrations for sarizotan 1 mg/kg alone or with L-Dopa, indicating a lack of sarizotan/L-Dopa interaction. The time course of plasma sarizotan concentrations was associated with time of maximal reduction of dyskinesias. When administered daily for two weeks in combination with L-Dopa in the same MPTP monkeys, sarizotan 1 mg/kg had a sustained antidyskinetic effect while maintaining the antiparkinsonian and locomotor effect of L-Dopa. This detailed sarizotan investigation in MPTP monkeys supports the antidyskinetic activity of this drug and for 5-HT(1A) agonists.
Chronis-Tuscano, Andrea; Seymour, Karen E; Stein, Mark A; Jones, Heather A; Jiles, Cynthia D; Rooney, Mary E; Conlon, Charles J; Efron, Lisa A; Wagner, Stephanie A; Pian, Jessica; Robb, Adelaide S
2008-12-01
A preliminary study to examine the efficacy of osmotic-release oral system (OROS) methylphenidate for attention-deficit/hyperactivity disorder (ADHD) symptoms and parenting behaviors in mothers with ADHD who had children with ADHD. Participants included 23 mother-child dyads in which both were diagnosed with DSM-IV ADHD. Mothers underwent a 5-week, double-blind titration (placebo, 36 mg/day, 54 mg/day, 72 mg/day, 90 mg/day) to an optimal dose of OROS methylphenidate, followed by random assignment to 2 weeks of placebo or their maximally effective dose. Primary outcome measures included maternal ADHD symptoms (Conners' Adult ADHD Rating Scale) and parenting (Alabama Parenting Questionnaire). Secondary outcomes included side effects ratings. Data were collected from December 2004 until August 2006. During Phase 1, mothers reported significant decreases in inattention (p < .001) and hyperactivity/impulsivity (p < .01) with increases in OROS methylphenidate dose. As dose increased, significant reductions in inconsistent discipline (p < .01) and corporal punishment use (p < .005) were also demonstrated. During Phase 2, small effects on inattention (d = 0.46) and hyperactivity/impulsivity (d = 0.38) were found for those randomly assigned to medication versus placebo. In addition, medium to large medication effects were found on maternal involvement (d = 0.52), poor monitoring/supervision (d = 0.70), and inconsistent discipline (d = 0.71), with small effects on corporal punishment (d = 0.42). During both phases, few adverse effects were noted. OROS methylphenidate was well tolerated and was associated with significant improvement in maternal ADHD symptoms and parenting. Variable effects on parenting suggest that behavioral interventions may be necessary to address impairments in parenting among adults with ADHD. clinicaltrials.gov Identifier: NCT00318981. Copyright 2008 Physicians Postgraduate Press, Inc.
A simplified model of the source channel of the Leksell GammaKnife® tested with PENELOPE
NASA Astrophysics Data System (ADS)
Al-Dweri, Feras M. O.; Lallena, Antonio M.; Vilches, Manuel
2004-06-01
Monte Carlo simulations using the code PENELOPE have been performed to test a simplified model of the source channel geometry of the Leksell GammaKnife®. The characteristics of the radiation passing through the treatment helmets are analysed in detail. We have found that only primary particles emitted from the source with polar angles smaller than 3° with respect to the beam axis are relevant for the dosimetry of the Gamma Knife. The photon trajectories reaching the output helmet collimators at (x, y, z = 236 mm) show strong correlations between rgr = (x2 + y2)1/2 and their polar angle thgr, on one side, and between tan-1(y/x) and their azimuthal angle phgr, on the other. This enables us to propose a simplified model which treats the full source channel as a mathematical collimator. This simplified model produces doses in good agreement with those found for the full geometry. In the region of maximal dose, the relative differences between both calculations are within 3%, for the 18 and 14 mm helmets, and 10%, for the 8 and 4 mm ones. Besides, the simplified model permits a strong reduction (larger than a factor 15) in the computational time.
A review of the efficacy and safety of oral antidiabetic drugs
Stein, Stephanie Aleskow; Lamos, Elizabeth Mary; Davis, Stephen N
2014-01-01
Introduction Additional oral antidiabetic agents to metformin, sulfonylureas (SU) and thiazolidinediones (TZD) are approved for the treatment of type 2 diabetes. Areas covered The efficacy and safety of metformin, SUs, TZDs, dipeptidyl peptidase-IV (DPP-4) inhibitors, meglitinide analogs, α-glucosidase inhibitors (AGIs), bile-acid sequestrants (BAS) and bromocriptine will be reviewed. Expert opinion Several new oral agents have been approved for type 2 diabetes management in recent years. It is important to understand the efficacy and safety of these medications in addition to the older agents to best maximize oral drug therapy for diabetes. Of the recently introduced oral hypoglycemic/antihyperglycemic agents, the DPP-4 inhibitors are moderately efficacious compared with mainstay treatment with metformin with a low side-effect profile and have good efficacy in combination with other oral agents and insulin. They are a recommended alternative when metformin use is limited by gastrointestinal (GI) side effects or when SU treatment results in significant hypoglycemia or weight gain. Meglitinide analogs are limited by their frequent dosing, expense and hypoglycemia (repaglinide > nateglinide), while AGIs are also limited by their dosing schedule and GI side-effect profile. BAS and bromocriptine have the lowest efficacy with regard to HbA1c reduction, also are plagued by GI adverse reactions, but have a low risk of hypoglycemia. PMID:23241069
Optimizing fluorescently tethered Hsp90 inhibitor dose for maximal specific uptake by breast tumors
NASA Astrophysics Data System (ADS)
Crouch, Brian T.; Duer, Joy; Wang, Roujia; Gallagher, Jennifer; Hall, Allison; Soo, Mary Scott; Hughes, Philip; Haystead, Timothy A. J.; Ramanujam, Nirmala
2018-03-01
Despite improvements in surgical resection, 20-40% of patients undergoing breast conserving surgery require at least one additional re-excision. Leveraging the unique surface expression of heat shock protein 90 (Hsp90), a chaperone protein involved in several key hallmarks of cancer, in breast cancer provides an exciting opportunity to identify residual disease during surgery. We developed a completely non-destructive strategy using HS-27, a fluorescently-tethered Hsp90 inhibitor, to assay surface Hsp90 expression on intact tissue specimens using a fluorescence microendoscope with a field of view of 750 μm and subcellular resolution of 4 μm. HS-27 consists of an FDA approved Hsp90 inhibitor tethered to fluorescein isothiocyanate (EX 488nm, EM 525nm). Here, we optimized ex vivo HS-27 administration in pre-clinical breast cancer models and validated our approach on 21 patients undergoing standard of care ultrasound guided core needle biopsy. HS-27 administration time was fixed at 1- minute to minimize imaging impact on clinical workflow. HS-27 and HS-217 (non-specific control) doses were modulated from 1 μM up to 100 μM to identify the dose maximizing the ratio of specific uptake (HS-27 fluorescence) to non-specific uptake (HS-217 fluorescence). The specificity ratio was maximized at 100 μM and was significantly greater than all other doses (p<0.05). We applied our optimized imaging protocol to clinical samples and demonstrated significantly greater uptake of HS-27 by tumor than non-tumor tissue (p<0.05). The ubiquitous nature of HS-27 binding to all subtypes of breast cancer makes this technology attractive for assessing tumor margins, as one agent can be used for all subtypes.
Tallis, Jason; Yavuz, Harley C M
2018-03-01
Despite the growing quantity of literature exploring the effect of caffeine on muscular strength, there is a dearth of data that directly explores differences in erogenicity between upper and lower body musculature and the dose-response effect. The present study sought to investigate the effects of low and moderate doses of caffeine on the maximal voluntary strength of the elbow flexors and knee extensors. Ten nonspecifically strength-trained, recreationally active participants (aged 21 ± 0.3 years) completed the study. Using a randomised, counterbalanced, and double-blind approach, isokinetic concentric and eccentric strength was measured at 60 and 180°/s following administration of a placebo, 3 mg·kg -1 body mass caffeine, and 6 mg·kg -1 body mass caffeine. There was no effect of caffeine on the maximal voluntary concentric and eccentric strength of the elbow flexors, or the eccentric strength of the knee extensors. Both 3 and 6 mg·kg -1 body mass caffeine caused a significant increase in peak concentric force of the knee extensors at 180°/s. No difference was apparent between the 2 concentrations. Only 6 mg·kg -1 body mass caused an increase in peak concentric force during repeated contractions. The results infer that the effective caffeine concentration to evoke improved muscle performance may be related to muscle mass and contraction type. The present work indicates that a relatively low dose of caffeine treatment may be effective for improving lower body muscular strength, but may have little benefit for the strength of major muscular groups of the upper body.
NASA Astrophysics Data System (ADS)
Kim, Jae-Sung; Chung, Jin-Beom; Kim, In-Ah; Eom, Keun-Yong
2013-10-01
We used an endorectal balloon (ERB) for prostate immobilization during intensity-modulated radiotherapy (IMRT) for prostate cancer treatment. To investigate the dosimetric effects of ERB-filling materials, we changed the ERB Hounsfield unit (HU) from 0 to 1000 HU in 200-HU intervals to simulate the various ERB fillings; 0 HU simulated a water-filled ERB, and 1000 HU simulated the densest material-filled ERB. Dosimetric data (coverage, homogeneity, conformity, maximal dose, and typical volume dose) for the tumor and the organs at risk (OARs) were evaluated in prostate IMRT treatment plans with 6-MV and 15-MV beams. The tumor coverage appeared to differ by approximately 1%, except for the clinical target volume (CTV) V100% and the planning target volume (PTV) V100%. The largest difference for the various ERB fillings was observed in the PTV V100%. In spite of increasing HU, the prostate IMRT plans at both energies had relatively low dosimetric effects on the PTV and the CTV. However, the maximal and the typical volume doses (D25%, D30%, and D50%) to the rectal wall and the bladder increased with increasing HU. For an air-filled ERB, the maximal doses to the rectal wall and the monitor units were lower than the corresponding values for the water-filled and the densest material-filled ERBs. An air-filled ERB spared the rectal wall because of its dosimetric effect. Thus, we conclude that the use of an air-filled ERB provides a dosimetric benefit to the rectal wall without a loss of target coverage and is an effective option for prostate IMRT treatment.
Geometric mean for subspace selection.
Tao, Dacheng; Li, Xuelong; Wu, Xindong; Maybank, Stephen J
2009-02-01
Subspace selection approaches are powerful tools in pattern classification and data visualization. One of the most important subspace approaches is the linear dimensionality reduction step in the Fisher's linear discriminant analysis (FLDA), which has been successfully employed in many fields such as biometrics, bioinformatics, and multimedia information management. However, the linear dimensionality reduction step in FLDA has a critical drawback: for a classification task with c classes, if the dimension of the projected subspace is strictly lower than c - 1, the projection to a subspace tends to merge those classes, which are close together in the original feature space. If separate classes are sampled from Gaussian distributions, all with identical covariance matrices, then the linear dimensionality reduction step in FLDA maximizes the mean value of the Kullback-Leibler (KL) divergences between different classes. Based on this viewpoint, the geometric mean for subspace selection is studied in this paper. Three criteria are analyzed: 1) maximization of the geometric mean of the KL divergences, 2) maximization of the geometric mean of the normalized KL divergences, and 3) the combination of 1 and 2. Preliminary experimental results based on synthetic data, UCI Machine Learning Repository, and handwriting digits show that the third criterion is a potential discriminative subspace selection method, which significantly reduces the class separation problem in comparing with the linear dimensionality reduction step in FLDA and its several representative extensions.
ANI/MAELU engineering inspection criteria 8.3 ALARA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schneider, L.
1995-03-01
The purpose of this criteria section is to provide guidelines for programs whose intent is to achieve occupational doses and doses to members of the public that are as low as is reasonably achievable (ALARA). The success that has been achieved by applying ALARA concepts at nuclear power plants is clearly illustrated by the major reductions in the annual cumulative dose to workers at many sites over the last few years. This success is the combined result of the general maturity of the nuclear industry, the intensive study of dose reduction practices by industry groups, and the successful sharing ofmore » experience and practices among plants. Source term reduction should be used as a primary ALARA mechanism. Methods which should be considered include: satellite and cobalt reduction, chemistry control, decontamination, submicron filters, zinc addition, hot spot reduction and permanent or temporary shielding.« less
Dong, J; Hayakawa, Y; Kober, C
2014-01-01
When metallic prosthetic appliances and dental fillings exist in the oral cavity, the appearance of metal-induced streak artefacts is not avoidable in CT images. The aim of this study was to develop a method for artefact reduction using the statistical reconstruction on multidetector row CT images. Adjacent CT images often depict similar anatomical structures. Therefore, reconstructed images with weak artefacts were attempted using projection data of an artefact-free image in a neighbouring thin slice. Images with moderate and strong artefacts were continuously processed in sequence by successive iterative restoration where the projection data was generated from the adjacent reconstructed slice. First, the basic maximum likelihood-expectation maximization algorithm was applied. Next, the ordered subset-expectation maximization algorithm was examined. Alternatively, a small region of interest setting was designated. Finally, the general purpose graphic processing unit machine was applied in both situations. The algorithms reduced the metal-induced streak artefacts on multidetector row CT images when the sequential processing method was applied. The ordered subset-expectation maximization and small region of interest reduced the processing duration without apparent detriments. A general-purpose graphic processing unit realized the high performance. A statistical reconstruction method was applied for the streak artefact reduction. The alternative algorithms applied were effective. Both software and hardware tools, such as ordered subset-expectation maximization, small region of interest and general-purpose graphic processing unit achieved fast artefact correction.
Zeng, Yaohui; Singh, Sachinkumar; Wang, Kai; Ahrens, Richard C
2018-04-01
Pharmacodynamic studies that use methacholine challenge to assess bioequivalence of generic and innovator albuterol formulations are generally designed per published Food and Drug Administration guidance, with 3 reference doses and 1 test dose (3-by-1 design). These studies are challenging and expensive to conduct, typically requiring large sample sizes. We proposed 14 modified study designs as alternatives to the Food and Drug Administration-recommended 3-by-1 design, hypothesizing that adding reference and/or test doses would reduce sample size and cost. We used Monte Carlo simulation to estimate sample size. Simulation inputs were selected based on published studies and our own experience with this type of trial. We also estimated effects of these modified study designs on study cost. Most of these altered designs reduced sample size and cost relative to the 3-by-1 design, some decreasing cost by more than 40%. The most effective single study dose to add was 180 μg of test formulation, which resulted in an estimated 30% relative cost reduction. Adding a single test dose of 90 μg was less effective, producing only a 13% cost reduction. Adding a lone reference dose of either 180, 270, or 360 μg yielded little benefit (less than 10% cost reduction), whereas adding 720 μg resulted in a 19% cost reduction. Of the 14 study design modifications we evaluated, the most effective was addition of both a 90-μg test dose and a 720-μg reference dose (42% cost reduction). Combining a 180-μg test dose and a 720-μg reference dose produced an estimated 36% cost reduction. © 2017, The Authors. The Journal of Clinical Pharmacology published by Wiley Periodicals, Inc. on behalf of American College of Clinical Pharmacology.
Gobburu, J V; Agersø, H; Jusko, W J; Ynddal, L
1999-09-01
To examine the pharmacokinetics (PK) and pharmacodynamics (PD) of ipamorelin, a growth hormone (GH) releasing peptide, in healthy volunteers. A trial was conducted with a dose escalation design comprising 5 different infusion rates (4.21, 14.02, 42.13, 84.27 and 140.45 nmol/kg over 15 minutes) with eight healthy male subjects at each dose level. Concentrations of ipamorelin and growth hormone were measured. The PK parameters showed dose-proportionality, with a short terminal half-life of 2 hours, a clearance of 0.078 L/h/kg and a volume of distribution at steady-state of 0.22 L/kg. The time course of GH stimulation by ipamorelin showed a single episode of GH release with a peak at 0.67 hours and an exponential decline to negligible GH concentration at all doses. The ipamorelin-GH concentration relationship was characterized using an indirect response model and population fitting. The model employed a zero-order GH release rate over a finite duration of time to describe the episodic release of GH. Ipamorelin induces the release of GH at all dose levels with the concentration (SC50) required for half-maximal GH stimulation of 214 nmol/L and a maximal GH production rate of 694 mIU/L/h. The inter-individual variability of the PD parameters was larger than that of the PK parameters. The proposed PK/PD model provides a useful characterization of ipamorelin disposition and GH responses across a range of doses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Taeho; Reardon, Kelli; Sukovich, Kaitlyn
Purpose: A 7.4% increase in major coronary events per 1 Gy increase in mean heart dose has been reported from the population-based analysis of radiation-induced cardiac toxicity following treatment of left sided breast cancer. Deep inhalation breath-hold (DIBH) is clinically utilized to reduce radiation dose to heart and left anterior descending artery (LAD). We investigated the correlation of dose sparing in heart and LAD with internal DIBH amplitude to develop a quantitative predictive model for expected dose to heart and LAD based on internal breath hold amplitude. Methods: A treatment planning study (Prescription Dose = 50 Gy) was performed onmore » 50 left breast cancer patients underwent DIBH whole breast radiotherapy. Two CT datasets, free breathing (FB) and DIBH, were utilized for treatment planning and for determination of the internal anatomy DIBH amplitude (difference between sternum position at FB and DIBH). The heart and LAD dose between FB and DIBH plans was compared and dose to the heart and LAD as a function of breath hold amplitude was determined. Results: Average DIBH amplitude using internal anatomy was 13.9±4.2 mm. The DIBH amplitude-mean dose reduction correlation is 20%/5mm (0.3 Gy/5mm) for the heart and 18%/5mm (1.1 Gy/5mm) for LAD. The correlation with max dose reduction is 12%/5mm (3.8 Gy/5mm) for the heart and 16%/5mm (3.2 Gy/5mm) for LAD. We found that average dose reductions to LAD from 6.0±6.5 Gy to 2.0±1.6 Gy with DIBH (4.0 Gy reduction: -67%, p < 0.001) and average dose reduction to the heart from 1.3±0.7 Gy to 0.7±0.2 Gy with DIBH (0.6 Gy reduction: -46%, p < 0.001). That suggests using DIBH may reduce the risk of the major coronary event for left sided breast cancer patients. Conclusion: The correlation between breath hold amplitude and dosimetric sparing suggests that dose sparing linearly increases with internal DIBH amplitude.« less
Latanoprost-Eluting Contact Lenses in Glaucomatous Monkeys.
Ciolino, Joseph B; Ross, Amy E; Tulsan, Rehka; Watts, Amy C; Wang, Rong-Fang; Zurakowski, David; Serle, Janet B; Kohane, Daniel S
2016-10-01
To assess the ability of latanoprost-eluting contact lenses to lower the intraocular pressure (IOP) of glaucomatous eyes of cynomolgus monkeys. Preclinical efficacy study of 3 treatment arms in a crossover design. Female cynomolgus monkeys with glaucoma induced in 1 eye by repeated argon laser trabeculoplasty. Latanoprost-eluting low-dose contact lenses (CLLO) and high-dose contact lenses (CLHI) were produced by encapsulating a thin latanoprost-polymer film within the periphery of a methafilcon hydrogel, which was lathed into a contact lens. We assessed the IOP-lowering effect of CLLO, CLHI, or daily latanoprost ophthalmic solution in the same monkeys. Each monkey consecutively received 1 week of continuous-wear CLLO, 3 weeks without treatment, 5 days of latanoprost drops, 3 weeks without treatment, and 1 week of continuous-wear CLHI. On 2 consecutive days before initiation of each study arm, the IOP was measured hourly over 7 consecutive hours to establish the baseline IOP. Two-tailed Student t tests and repeated-measures analysis of variance were used for statistical analysis. Intraocular pressure. Latanoprost ophthalmic solution resulted in IOP reduction of 5.4±1.0 mmHg on day 3 and peak IOP reduction of 6.6±1.3 mmHg on day 5. The CLLO reduced IOP by 6.3±1.0, 6.7±0.3, and 6.7±0.3 mmHg on days 3, 5, and 8, respectively. The CLHI lowered IOP by 10.5±1.4, 11.1±4.0, and 10.0±2.5 mmHg on days 3, 5, and 8, respectively. For the CLLO and CLHI, the IOP was statistically significantly reduced compared with the untreated baseline at most time points measured. The CLHI demonstrated greater IOP reduction than latanoprost ophthalmic solution on day 3 (P = 0.001) and day 5 (P = 0.015), and at several time points on day 8 (P < 0.05). Sustained delivery of latanoprost by contact lenses is at least as effective as delivery with daily latanoprost ophthalmic solution. More research is needed to determine the optimal continuous-release dose that would be well tolerated and maximally effective. Contact lens drug delivery may become an option for the treatment of glaucoma and a platform for ocular drug delivery. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Gatidis, Sergios; Würslin, Christian; Seith, Ferdinand; Schäfer, Jürgen F; la Fougère, Christian; Nikolaou, Konstantin; Schwenzer, Nina F; Schmidt, Holger
2016-01-01
Optimization of tracer dose regimes in positron emission tomography (PET) imaging is a trade-off between diagnostic image quality and radiation exposure. The challenge lies in defining minimal tracer doses that still result in sufficient diagnostic image quality. In order to find such minimal doses, it would be useful to simulate tracer dose reduction as this would enable to study the effects of tracer dose reduction on image quality in single patients without repeated injections of different amounts of tracer. The aim of our study was to introduce and validate a method for simulation of low-dose PET images enabling direct comparison of different tracer doses in single patients and under constant influencing factors. (18)F-fluoride PET data were acquired on a combined PET/magnetic resonance imaging (MRI) scanner. PET data were stored together with the temporal information of the occurrence of single events (list-mode format). A predefined proportion of PET events were then randomly deleted resulting in undersampled PET data. These data sets were subsequently reconstructed resulting in simulated low-dose PET images (retrospective undersampling of list-mode data). This approach was validated in phantom experiments by visual inspection and by comparison of PET quality metrics contrast recovery coefficient (CRC), background-variability (BV) and signal-to-noise ratio (SNR) of measured and simulated PET images for different activity concentrations. In addition, reduced-dose PET images of a clinical (18)F-FDG PET dataset were simulated using the proposed approach. (18)F-PET image quality degraded with decreasing activity concentrations with comparable visual image characteristics in measured and in corresponding simulated PET images. This result was confirmed by quantification of image quality metrics. CRC, SNR and BV showed concordant behavior with decreasing activity concentrations for measured and for corresponding simulated PET images. Simulation of dose-reduced datasets based on clinical (18)F-FDG PET data demonstrated the clinical applicability of the proposed data. Simulation of PET tracer dose reduction is possible with retrospective undersampling of list-mode data. Resulting simulated low-dose images have equivalent characteristics with PET images actually measured at lower doses and can be used to derive optimal tracer dose regimes.
A trace ratio maximization approach to multiple kernel-based dimensionality reduction.
Jiang, Wenhao; Chung, Fu-lai
2014-01-01
Most dimensionality reduction techniques are based on one metric or one kernel, hence it is necessary to select an appropriate kernel for kernel-based dimensionality reduction. Multiple kernel learning for dimensionality reduction (MKL-DR) has been recently proposed to learn a kernel from a set of base kernels which are seen as different descriptions of data. As MKL-DR does not involve regularization, it might be ill-posed under some conditions and consequently its applications are hindered. This paper proposes a multiple kernel learning framework for dimensionality reduction based on regularized trace ratio, termed as MKL-TR. Our method aims at learning a transformation into a space of lower dimension and a corresponding kernel from the given base kernels among which some may not be suitable for the given data. The solutions for the proposed framework can be found based on trace ratio maximization. The experimental results demonstrate its effectiveness in benchmark datasets, which include text, image and sound datasets, for supervised, unsupervised as well as semi-supervised settings. Copyright © 2013 Elsevier Ltd. All rights reserved.
Leveraging Hypoxia-Activated Prodrugs to Prevent Drug Resistance in Solid Tumors.
Lindsay, Danika; Garvey, Colleen M; Mumenthaler, Shannon M; Foo, Jasmine
2016-08-01
Experimental studies have shown that one key factor in driving the emergence of drug resistance in solid tumors is tumor hypoxia, which leads to the formation of localized environmental niches where drug-resistant cell populations can evolve and survive. Hypoxia-activated prodrugs (HAPs) are compounds designed to penetrate to hypoxic regions of a tumor and release cytotoxic or cytostatic agents; several of these HAPs are currently in clinical trial. However, preliminary results have not shown a survival benefit in several of these trials. We hypothesize that the efficacy of treatments involving these prodrugs depends heavily on identifying the correct treatment schedule, and that mathematical modeling can be used to help design potential therapeutic strategies combining HAPs with standard therapies to achieve long-term tumor control or eradication. We develop this framework in the specific context of EGFR-driven non-small cell lung cancer, which is commonly treated with the tyrosine kinase inhibitor erlotinib. We develop a stochastic mathematical model, parametrized using clinical and experimental data, to explore a spectrum of treatment regimens combining a HAP, evofosfamide, with erlotinib. We design combination toxicity constraint models and optimize treatment strategies over the space of tolerated schedules to identify specific combination schedules that lead to optimal tumor control. We find that (i) combining these therapies delays resistance longer than any monotherapy schedule with either evofosfamide or erlotinib alone, (ii) sequentially alternating single doses of each drug leads to minimal tumor burden and maximal reduction in probability of developing resistance, and (iii) strategies minimizing the length of time after an evofosfamide dose and before erlotinib confer further benefits in reduction of tumor burden. These results provide insights into how hypoxia-activated prodrugs may be used to enhance therapeutic effectiveness in the clinic.
Hirsch, Sheldon; Hirsch, Jackie; Bhatt, Udayan; Rovin, Brad H
2012-01-01
Blood pressure (BP) reduction in patients with chronic kidney disease (CKD), particularly with a renin-angiotensin system inhibitor (RASI), commonly leads to an initial decrease in glomerular filtration rate. The current clinical guideline, based on studies with single RASIs, is to tolerate an increase in the serum creatinine only up to 30%. This guideline has aptly guided CKD care for over a decade, but should be updated in the contemporary context of more aggressive RASI and diuretic use. This study is a retrospective review of 48 mostly African-American patients with CKD treated with multiple and/or high-dose renin-angiotensin system (RAS) inhibition and diuretics, targeting both low BP and reduction of urine protein. RASI was not reduced in response to initial increases in serum creatinine greater than 30%. A clinically well-tolerated increase in serum creatinine over 30% during the first year occurred in 41% of the patients. Treatment was unaltered, and target goals for BP and urine protein were typically achieved. After the point of maximal serum creatinine in the first year, these patients had minimal progression of disease over the next 6 years, with a long-term estimated glomerular filtration rate slope of only -0.52 ml/min/year/1.73 m(2). Only 25% progressed to end-stage renal disease or death. The 30% limitation to initial increases in the serum creatinine still pertains for single RASI at usual doses. However, favorable long-term outcomes suggest that initial increases over 30% should be tolerated in the context of dual goal-directed, more aggressive RASI and diuretic use. Copyright © 2012 S. Karger AG, Basel.
Vogelbaum, Michael A; Angelov, Lilyana; Lee, Shih-Yuan; Li, Liang; Barnett, Gene H; Suh, John H
2006-06-01
The maximal tolerated dose (MTD) for stereotactic radiosurgery (SRS) for brain tumors was established by the Radiation Therapy Oncology Group (RTOG) in protocol 90-05, which defined three dose groups based on the maximal tumor diameter. The goal in this retrospective study was to determine whether differences in doses to the margins of brain metastases affect the ability of SRS to achieve local control. Between 1997 and 2003, 202 patients harboring 375 tumors that met study entry criteria underwent SRS for treatment of one or multiple brain metastases. The median overall follow-up duration was 10.7 months (range 3-83 months). A dose of 24 Gy to the tumor margin had a significantly lower risk of local failure than 15 or 18 Gy (p = 0.0005; hazard ratio 0.277, confidence interval [CI] 0.134-0.573), whereas the 15- and 18-Gy groups were not significantly different from each other (p = 0.82) in this regard. The 1-year local control rate was 85% (95% CI 78-92%) in tumors treated with 24 Gy, compared with 49% (CI 30-68%) in tumors treated with 18 Gy and 45% (CI 23-67%) in tumors treated with 15 Gy. Overall patient survival was independent of dose to the tumor margin. Use of the RTOG 90-05 dosing scheme for brain metastases is associated with a variable local control rate. Tumors larger than 2 cm are less effectively controlled than smaller lesions, which can be safely treated with 24 Gy. Prospective evaluations of the relationship between dose to the tumor margin and local control should be performed to confirm these observations.
Higashioka, Kazuhiko; Niiro, Hiroaki; Yoshida, Kenji; Oryoji, Kensuke; Kamada, Kazuo; Mizuki, Shinichi; Yokota, Eisuke
2016-01-01
Low-dose trimethoprim-sulfamethoxazole (TMP-SMX) is commonly used to prevent pneumocystis pneumonia in daily practice. Previous reports have shown a relationship between high- or standard-dose of TMP-SMX and hyperkalemia, however it remains unclear whether this is true for low-dose TMP-SMX. In this study we sought to determine the risk factors for hyperkalemia associated with low-dose TMP-SMX. In this retrospective cohort study, 186 consecutive adult patients who received TMP-SMX as prophylaxis for pneumocystis pneumonia from January 2014 to January 2015 were evaluated. Data on the patients' age, gender, baseline estimated glomerular filtration rate (eGFR), baseline serum potassium, maximum serum potassium, duration reaching the maximal serum potassium level, dosage, and concomitant use of angiotensin-converting enzyme inhibitors (ACEi)/angiotensin receptor blockers (ARB), β-blockers, non-steroidal anti-inflammatory drugs and potassium-sparing diuretics were retrospectively collected. Hyperkalemia was defined as a serum potassium level ≥5 mEq/L. Univariate and multivariate analyses were performed. The median age of the patients was 66 years and 51.1% were men. Hyperkalemia associated with low-dose TMP-SMX was observed in 32 patients (17.2%). The median duration to reach the maximal serum potassium level was 12 days. The multivariate logistic regression analysis identified renal insufficiency to be a major risk factor for hyperkalemia associated with low-dose TMP-SMX (eGFR <60 mL/min/1.73 m(2), adjusted OR 4.62). Moreover, in the subpopulation of patients with renal insufficiency, ACEi/ARB use was considered to be a major risk factor for hyperkalemia (adjusted OR 3.96). Renal insufficiency in concert with ACEi/ARB use is a major risk factor for hyperkalemia induced by low-dose TMP-SMX.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Song, Y; Gan, L; Chen, X
Purpose: To explore the correlations between anatomic features and dose-volumetric parameters in 3DCRT and eComp whole breast irradiation and identify the feasibility of anatomic parameters to predict the planning method selection. Methods: We compared the effectiveness between conventional three-dimensional conformal radiotherapy (3DCRT) and electronic tissue compensation (eComp) for whole breast irradiation. 3DCRT and eComp planning techniques were used to generate treatment plans for 60 whole breast patients, respectively. The planning goal was to cover 95% of the planning target volume (PTV) with 95% of the prescription dose while minimizing dose to lung, heart, and skin. Statistical analyses were performed betweenmore » critical organ doses and patient anatomic features, i.e., central lung distance (CLD), maximal heart distance (MHD), maximal heart length (MHL) and breast separation (BS). Results: Comparing to 3DCRT plans, on the average, eComp treatment planning process was about 7 minutes longer, but resulted in lower lung V20Gy, lower mean skin dose, with similar heart dose. The benefits were more pronounced for larger breast patients. To keep the lung V20Gy lower than 20% and mean skin dose lower than 85% of the prescription dose, eComp was the preferred method for patients with more than 2.3 cm CLD or larger than 22.5 cm BS. Conclusion: The study results may be useful in providing a handy criterion in clinical practice allowing us to easily choose between different planning techniques to satisfy the planning goal with minimal increase in complexity and cost. This study was supported by National Natural Science Foundation of China (NO. 31420103915) and Chongqing Health and Family Planning Commission Project (2015MSXM012).« less
Segovia, Javier; Gerosa, Gino; Almenar, Luis; Livi, Ugolino; Viganò, Mario; Arizón, Jose Maria; Yonan, Nizar; Di Salvo, Thomas G; Renlund, Dale G; Kobashigawa, Jon A
2008-01-01
Mycophenolic acid (MPA) dose reduction is associated with increased risk of rejection and graft loss in renal transplantation. This analysis investigated the impact of MPA dose changes with enteric-coated mycophenolate sodium (EC-MPS) or mycophenolate mofetil (MMF) in de novo heart transplant recipients. In a 12-month, single-blind trial, 154 patients (EC-MPS, 78; MMF, 76) were randomized to either EC-MPS (1080 mg bid) or MMF (1500 mg bid) in combination with cyclosporine and steroids. The primary efficacy variable was the incidence of treatment failure, comprising a composite of biopsy-proven (BPAR) and treated acute rejection, graft loss or death. Significantly fewer patients receiving EC-MPS required > or =2 dose reductions than patients on MMF (26.9% vs. 42.1% of patients, p = 0.048). Accordingly, the average daily dose of EC-MPS as a percentage of the recommended dose was significantly higher than for MMF (88.4% vs. 79.0%, p = 0.016). Among patients requiring > or =1 dose reduction, the incidence of treated BPAR grade > or =3A was significantly lower with EC-MPS compared with MMF (23.4% vs. 44.0%, p = 0.032). These data suggest that EC-MPS-treated heart transplant patients are less likely to require multiple dose reductions than those on MMF which may be associated with a significantly lower risk of treated BPAR > or =3A.
SU-F-J-48: Effect of Scan Length On Magnitude of Imaging Dose in KV CBCT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deshpande, S; Naidu, S; Sutar, A
Purpose: To study effect of scan length on magnitude of imaging dose deposition in Varian kV CBCT for head & neck and pelvis CBCT. Methods: To study effect of scan length we measured imaging dose at depth of 8 cm for head and neck Cone Beam Computed Tomography (CBCT) acquisition ( X ray beam energy is used 100kV and 200 degree of gantry rotation) and at 16 cm depth for pelvis CBCT acquisition ( X ray beam energy used is 125 kV and 360 degree of gantry rotation) in specially designed phantom. We used farmer chamber which was calibrated inmore » kV X ray range for measurements .Dose was measured with default field size, and reducing field size along y direction to 10 cm and 5 cm. Results: As the energy of the beam decreases the scattered radiation increases and this contributes significantly to the dose deposited in the patient. By reducing the scan length to 10 Cm from default 20.6 cm we found a dose reduction of 14% for head and neck CBCT protocol and a reduction of 26% for pelvis CBCT protocol. Similarly for a scan length of 5cm compared to default the dose reduction in head and neck CBCT protocol is 36% while in the pelvis CBCT protocol the dose reduction is 50%. Conclusion: By limiting the scan length we can control the scatter radiation generated and hence the dose to the patient. However the variation in dose reduction for same length used in two protocols is because of the scan geometry. The pelvis CBCT protocol uses a full rotation and head and neck CBCT protocol uses partial rotation.« less
Gariani, Joanna; Martin, Steve P; Botsikas, Diomidis; Becker, Christoph D; Montet, Xavier
2018-06-14
To compare radiation dose and image quality of thoracoabdominal scans obtained with a high-pitch protocol (pitch 3.2) and iterative reconstruction (Sinogram Affirmed Iterative Reconstruction) in comparison to standard pitch reconstructed with filtered back projection (FBP) using dual source CT. 114 CT scans (Somatom Definition Flash, Siemens Healthineers, Erlangen, Germany), 39 thoracic scans, 54 thoracoabdominal scans and 21 abdominal scans were performed. Analysis of three protocols was undertaken; pitch of 1 reconstructed with FBP, pitch of 3.2 reconstructed with SAFIRE, pitch of 3.2 with stellar detectors reconstructed with SAFIRE. Objective and subjective image analysis were performed. Dose differences of the protocols used were compared. Dose was reduced when comparing scans with a pitch of 1 reconstructed with FBP to high-pitch scans with a pitch of 3.2 reconstructed with SAFIRE with a reduction of volume CT dose index of 75% for thoracic scans, 64% for thoracoabdominal scans and 67% for abdominal scans. There was a further reduction after the implementation of stellar detectors reflected in a reduction of 36% of the dose-length product for thoracic scans. This was not at the detriment of image quality, contrast-to-noise ratio, signal-to-noise ratio and the qualitative image analysis revealed a superior image quality in the high-pitch protocols. The combination of a high pitch protocol with iterative reconstruction allows significant dose reduction in routine chest and abdominal scans whilst maintaining or improving diagnostic image quality, with a further reduction in thoracic scans with stellar detectors. Advances in knowledge: High pitch imaging with iterative reconstruction is a tool that can be used to reduce dose without sacrificing image quality.
Zinner, Stephen H; Vostrov, Sergey N; Alferova, Irene V; Lubenko, Irene Yu; Portnoy, Yury A; Firsov, Alexander A
2004-08-01
The killing kinetics of Escherichia coli and Pseudomonas aeruginosa were compared when exposed to ABT492 and ciprofloxacin. E. coli ATCC 25922 and a clinical isolate of P. aeruginosa 4226 were exposed to ABT492 (single dose) and ciprofloxacin (two 12 h doses) at the ratios of area under the curve (AUC) to MIC varying from 60 to 480 h and at clinically achievable AUC/MIC ratios of ABT492 (1,740 and 140 h, respectively) and ciprofloxacin (2,200 and 120 h, respectively) that correspond to a 400 mg dose of ABT492 and two 500 mg doses of ciprofloxacin. In addition, a double dose of ABT492 (800 mg; AUC/MIC 280 h) and two 12 h doses of ABT492 (2 x 400 mg) were used with P. aeruginosa. Maximal reductions in the starting inoculum of E. coli and P. aeruginosa were greater with ABT492 than with ciprofloxacin at a given AUC/MIC ratio (60-480 h), whereas the times to regrowth were shorter with ABT492. A specific AUC/MIC relationship of the antimicrobial effect was inherent in each quinolone-pathogen pair. With both E. coli and P. aeruginosa, AUC/MIC plots of the area between the control growth and the time-kill curves (I(E)) were steeper for ciprofloxacin than ABT492 and they were species-independent. The effect of ABT492 on E. coli at the clinically achievable AUC/MIC ratio (1740h) was more pronounced than the respective AUC/MIC of ciprofloxacin (2,200 h). With P. aeruginosa, a 140 h AUC/MIC of ABT492 (400 mg as a single dose) provided 1.8-fold less effect than a 120 h AUC/MIC of ciprofloxacin (2 x 500 mg). However, two 12 h doses of ABT492 (AUC/MIC 2 x 140 h) but not a double single dose (800 mg) were more efficient than ciprofloxacin. These findings predict comparable efficacies of clinically achievable AUC/MICs of ABT492 and ciprofloxacin against E. coli (q.d. versus b.i.d. quinolone dosing) and P. aeruginosa at b.i.d. but not at q.d. ABT492.
A new biostimulation approach based on the concept of remaining P for soil bioremediation.
Júlio, Aline Daniela Lopes; Fernandes, Rita de Cássia Rocha; Costa, Maurício Dutra; Neves, Júlio César Lima; Rodrigues, Edmo Montes; Tótola, Marcos Rogério
2018-02-01
C:N:P ratio is generally adopted to estimate the amount of nitrogen and phosphorus to be added to soils to accelerate biodegradation of organic contaminants. However, differences in P fixation among soils lead to varying amounts of available P when a specific dose of the element is applied to different soils. Thus, the application of fertilizers to achieve a previously established C:P ratio leads to biodegradation rates that can be lower than the theoretical maximum. In this study, we developed an equation to estimate the dose of P required to maximize organic contaminant biodegradation in soils as a function of remaining P (P-rem), using diesel as a model contaminant. The soils were contaminated with diesel and received six doses of P. CO 2 emission was used to estimate biodegradation of hydrocarbons. Biodegradation increased with P doses. The P level that provided the highest hydrocarbon biodegradation rate showed linear and negative correlation with P-rem. The result shows that the requirement for P decreases as the P-rem of the soil increases (or the P-fixing capacity decreases). The dose of P recommended to maximize hydrocarbon biodegradation rate in soil can be estimated by the formula P (mg/dm 3 ) = 436.5-5.39 × P-rem (mg/L). Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu Lin Li; Robertson, D.H.; Chambers, J.Q.
1996-10-01
This work describes the electrochemical reduction of nitrate in alkaline solutions. Conditions which maximize the current efficiency for the production of dinitrogen and/or ammonia gases could be very important for the treatment of radioactive waste solutions.
ERIC Educational Resources Information Center
Kraft, Matthew A.
2013-01-01
Research has shown that "last hired, first fired" policies maximize the number of teachers subject to reductions in force by eliminating those teachers that are lowest on the pay scale first. Until now, advocates of effectiveness-based reduction-in-force (RIF) policies could only point to simulated policy exercises as evidence of the…
Tanaka, Masamitsu; Kinoshita, Manabu; Yoshihara, Yasuo; Shinomiya, Nariyoshi; Seki, Shuhji; Nemoto, Koichi; Hamblin, Michael R.; Morimoto, Yuji
2011-01-01
Background and Objective Bacterial arthritis does not respond well to antibiotics and moreover multidrug resistance is spreading. We previously tested photodynamic therapy (PDT) mediated by systemic Photofrin® in a mouse model of methicillin-resistant Staphylococcus aureus (MRSA) arthritis, but found that neutrophils were killed by PDT and therefore the infection was potentiated. Study Design/Materials and Methods The present study used an intra-articular injection of Photofrin® and optimized the light dosimetry in order to maximize bacterial killing and minimize killing of host neutrophils. MRSA (5 × 107 CFU) was injected into the mouse knee followed 3 days later by 1 μg of Photofrin® and 635-nm diode laser illumination with a range of fluences within 5 minutes. Synovial fluid was sampled 6 hours or 1–3, 5, and 7 days after PDT to determine MRSA colony-forming units (CFU), neutrophil numbers, and levels of cytokines. Results A biphasic light dose response was observed with the greatest reduction of MRSA CFU seen with a fluence of 20 J cm−2, whereas lower antibacterial efficacy was observed with fluences that were either lower or higher. Consistent with these results, a significantly higher concentration of macrophage inflammatory protein-2, a CXC chemokine, and greater accumulation of neutrophils were seen in the infected knee joint after PDT with a fluence of 20 J cm−2 compared to fluences of 5 or 70 J cm−2. Conclusion PDT for murine MRSA arthritis requires appropriate light dosimetry to simultaneously maximize bacterial killing and neutrophil accumulation into the infected site, while too little light does not kill sufficient bacteria and too much light kills neutrophils and damages host tissue as well as bacteria and allows bacteria to grow unimpeded by host defense. PMID:21412806
REDUCTION OF DOSES IN DIAGNOSTIC USES OF RADIOISOTOPES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hosain, F.
1960-03-01
> A moderately low-level counting technique with anticoincidence gas- flow counter was developed for use in metabolic and diagnostic tracer studies with radioisotopes. Several important experiments and results were reported which have been carried out with reduced doses of tracer isotopes. A reduction of the tracer dose of ahout 1/30th of the present conventional doses was achieved which helps to minimize the chances of radiation hazards. (auth)
Takeuchi, Hiroyoshi; Suzuki, Takefumi; Bies, Robert R; Remington, Gary; Watanabe, Koichiro; Mimura, Masaru; Uchida, Hiroyuki
2014-11-01
While acute-phase antipsychotic response has been attributed to 65%-80% dopamine D₂ receptor blockade, the degree of occupancy for relapse prevention in the maintenance treatment of schizophrenia remains unknown. In this secondary study of an open-label, 28-week, randomized, controlled trial conducted between April 2009 and August 2011, clinically stable patients with schizophrenia (DSM-IV) treated with risperidone or olanzapine were randomly assigned to the reduction group (dose reduced by 50%) or maintenance group (dose kept constant). Plasma antipsychotic concentrations at peak and trough before and after dose reduction were estimated with population pharmacokinetic techniques, using 2 collected plasma samples. Corresponding dopamine D₂ occupancy levels were then estimated using the model we developed. Relapse was defined as worsening in 4 Positive and Negative Syndrome Scale-Positive subscale items: delusion, conceptual disorganization, hallucinatory behavior, and suspiciousness. Plasma antipsychotic concentrations were available for 16 and 15 patients in the reduction and maintenance groups, respectively. Estimated dopamine D₂ occupancy (mean ± SD) decreased following dose reduction from 75.6% ± 4.9% to 66.8% ± 6.4% at peak and 72.3% ± 5.7% to 62.0% ± 6.8% at trough. In the reduction group, 10 patients (62.5%) did not demonstrate continuous D₂ receptor blockade above 65% (ie, < 65% at trough) after dose reduction; furthermore, 7 patients (43.8%) did not achieve a threshold of 65% occupancy even at peak. Nonetheless, only 1 patient met our relapse criteria after dose reduction during the 6 months of the study. The results suggest that the therapeutic threshold regarding dopamine D₂ occupancy may be lower for those who are stable in antipsychotic maintenance versus acute-phase treatment. Positron emission tomography studies are warranted to further test our preliminary findings. UMIN Clinical Trials Registry identifier: UMIN000001834. © Copyright 2014 Physicians Postgraduate Press, Inc.
Analgesic and anti-inflammatory effects of Mangifera indica L. extract (Vimang).
Garrido, G; González, D; Delporte, C; Backhouse, N; Quintero, G; Núñez-Sellés, A J; Morales, M A
2001-02-01
Vimang is an aqueous extract of Mangifera indica used in Cuba to improve the quality of life in patients suffering from elevated stress. To assess its possible analgesic and antiinflammatory effects, the results of a standard extract evaluation are presented. Analgesia was determined using acetic acid-induced abdominal constriction and formalin-induced licking. Antiinflammatory effects were evaluated using carrageenan- and formalin-induced oedema. Vimang (50-1000 mg/kg, p.o.) exhibited a potent and dose-dependent antinociceptive effect against acetic acid test in mice. The mean potency (DE(50)) was 54.5 mg/kg and the maximal inhibition attained was 94.4%. Vimang (20-1000 mg/kg, p.o.) dose-dependently inhibited the second phase of formalin-induced pain but not the first phase. The DE(50) of the second phase was 8.4 mg/kg and the maximal inhibition was 99.5%, being more potent than indomethacin at doses of 20 mg/kg. Vimang (20-1000 mg/kg, p.o.) significantly inhibited oedema formation (p < 0.01 or p < 0.05) of both carrageenan- and formalin-induced oedema in rat, guinea-pigs and mice (maximal inhibitions: 39.5, 45.0 and 48.6, respectively). The inhibitions were similar to those produced by indomethacin and sodium naproxen, p.o. The different polyphenols found in Vimang could account for the antinociceptive and antiinflammatory actions reported here for the first time for M. indica bark aqueous extract. Copyright 2001 John Wiley & Sons, Ltd.
Determinants of cell-to-cell variability in protein kinase signaling.
Jeschke, Matthias; Baumgärtner, Stephan; Legewie, Stefan
2013-01-01
Cells reliably sense environmental changes despite internal and external fluctuations, but the mechanisms underlying robustness remain unclear. We analyzed how fluctuations in signaling protein concentrations give rise to cell-to-cell variability in protein kinase signaling using analytical theory and numerical simulations. We characterized the dose-response behavior of signaling cascades by calculating the stimulus level at which a pathway responds ('pathway sensitivity') and the maximal activation level upon strong stimulation. Minimal kinase cascades with gradual dose-response behavior show strong variability, because the pathway sensitivity and the maximal activation level cannot be simultaneously invariant. Negative feedback regulation resolves this trade-off and coordinately reduces fluctuations in the pathway sensitivity and maximal activation. Feedbacks acting at different levels in the cascade control different aspects of the dose-response curve, thereby synergistically reducing the variability. We also investigated more complex, ultrasensitive signaling cascades capable of switch-like decision making, and found that these can be inherently robust to protein concentration fluctuations. We describe how the cell-to-cell variability of ultrasensitive signaling systems can be actively regulated, e.g., by altering the expression of phosphatase(s) or by feedback/feedforward loops. Our calculations reveal that slow transcriptional negative feedback loops allow for variability suppression while maintaining switch-like decision making. Taken together, we describe design principles of signaling cascades that promote robustness. Our results may explain why certain signaling cascades like the yeast pheromone pathway show switch-like decision making with little cell-to-cell variability.
Effect of insulin-like factors on glucose transport activity in unweighted rat skeletal muscle
NASA Technical Reports Server (NTRS)
Henriksen, Erik J.; Ritter, Leslie S.
1993-01-01
The effect of 3 or 6 days of unweighting on glucose transport activity, as assessed by 2-deoxyglucose uptake, in soleus strips stimulated by maximally effective concentrations of insulin, IGF-I, vanadate, or phospholipase C (PLC) is examined. Progressively increased responses to maximally effective doses of insulin or insulin-like growth factor were observed after 3 and 6 days of unweighting compared with weight matched control strips. Enhanced maximal responses to vanadate (6 days only) and PLC (3 and 6 days) were also observed. The data provide support for the existance of postreceptor binding mechanisms for the increased action of insulin on the glucose transport system in unweighted rat skeletal muscle.
Theophilus, Eugenia H; Coggins, Christopher R E; Chen, Peter; Schmidt, Eckhardt; Borgerding, Michael F
2015-03-01
Tobacco toxicant-related exposure reduction is an important tool in harm reduction. Cigarette per day reduction (CPDR) occurs as smokers migrate from smoking cigarettes to using alternative tobacco/nicotine products, or quit smoking. Few reports characterize the dose-response relationships between CPDR and effects on exposure biomarkers, especially at the low end of CPD exposure (e.g., 5 CPD). We present data on CPDR by characterizing magnitudes of biomarker reductions. We present data from a well-controlled, one-week clinical confinement study in healthy smokers who were switched from smoking 19-25 CPD to smoking 20, 10, 5 or 0 CPD. Biomarkers were measured in blood, plasma, urine, and breath, and included smoke-related toxicants, urine mutagenicity, smoked cigarette filter analyses (mouth level exposure), and vital signs. Many of the biomarkers (e.g., plasma nicotine) showed strong CPDR dose-response reductions, while others (e.g., plasma thiocyanate) showed weaker dose-response reductions. Factors that lead to lower biomarker reductions include non-CPD related contributors to the measured response (e.g., other exposure sources from environment, life style, occupation; inter-individual variability). This study confirms CPDR dose-responsive biomarkers and suggests that a one-week design is appropriate for characterizing exposure reductions when smokers switch from cigarettes to new tobacco products. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Calipari, Erin S.; Ferris, Mark J.; Jones, Sara R.
2013-01-01
Tolerance to the neurochemical and psychoactive effects of cocaine after repeated use is a hallmark of cocaine addiction in humans. However, comprehensive studies on tolerance to the behavioral, psychoactive, and neurochemical effects of cocaine following contingent administration in rodents are lacking. We outlined the consequences of extended access cocaine self-administration as it related to tolerance to the psychomotor activating, dopamine (DA) elevating, and DA transporter (DAT) inhibiting effects of cocaine. Cocaine self-administration (1.5 mg/kg/inj; 40 inj; 5 days), which resulted in escalation of first hour intake, caused reductions in evoked DA release and reduced maximal rates of uptake through the DAT as measured by slice voltammetry in the nucleus accumbens core. Further, we report reductions in cocaine-induced uptake inhibition as measured by fast scan cyclic voltammetry, and a corresponding increase in the dose of cocaine required for 50% inhibition of DA uptake (Ki) at the DAT. Cocaine tolerance at the DAT translated to reductions in cocaine-induced DA overflow as measured by microdialysis. Additionally, cocaine-induced elevations in locomotor activity and stereotypy were reduced, while rearing behavior was enhanced in animals with a history of cocaine self-administration. Here we demonstrate both neurochemical and behavioral cocaine tolerance in an extended-access rodent model of cocaine abuse, which allows for a better understanding of the neurochemical and psychomotor tolerance that develops to cocaine in human addicts. PMID:24102293
Power, S; Mirza, M; Thakorlal, A; Ganai, B; Gavagan, L D; Given, M F; Lee, M J
2015-06-01
This prospective pilot study was undertaken to evaluate the feasibility and effectiveness of using a radiation absorbing shield to reduce operator dose from scatter during lower limb endovascular procedures. A commercially available bismuth shield system (RADPAD) was used. Sixty consecutive patients undergoing lower limb angioplasty were included. Thirty procedures were performed without the RADPAD (control group) and thirty with the RADPAD (study group). Two separate methods were used to measure dose to a single operator. Thermoluminescent dosimeter (TLD) badges were used to measure hand, eye, and unshielded body dose. A direct dosimeter with digital readout was also used to measure eye and unshielded body dose. To allow for variation between control and study groups, dose per unit time was calculated. TLD results demonstrated a significant reduction in median body dose per unit time for the study group compared with controls (p = 0.001), corresponding to a mean dose reduction rate of 65 %. Median eye and hand dose per unit time were also reduced in the study group compared with control group, however, this was not statistically significant (p = 0.081 for eye, p = 0.628 for hand). Direct dosimeter readings also showed statistically significant reduction in median unshielded body dose rate for the study group compared with controls (p = 0.037). Eye dose rate was reduced for the study group but this was not statistically significant (p = 0.142). Initial results are encouraging. Use of the shield resulted in a statistically significant reduction in unshielded dose to the operator's body. Measured dose to the eye and hand of operator were also reduced but did not reach statistical significance in this pilot study.
NASA Astrophysics Data System (ADS)
Fahmi, Rachid; Eck, Brendan L.; Vembar, Mani; Bezerra, Hiram G.; Wilson, David L.
2014-03-01
We investigated the use of an advanced hybrid iterative reconstruction (IR) technique (iDose4, Philips Health- care) for low dose dynamic myocardial CT perfusion (CTP) imaging. A porcine model was created to mimic coronary stenosis through partial occlusion of the left anterior descending (LAD) artery with a balloon catheter. The severity of LAD occlusion was adjusted with FFR measurements. Dynamic CT images were acquired at end-systole (45% R-R) using a multi-detector CT (MDCT) scanner. Various corrections were applied to the acquired scans to reduce motion and imaging artifacts. Absolute myocardial blood flow (MBF) was computed with a deconvolution-based approach using singular value decomposition (SVD). We compared a high and a low dose radiation protocol corresponding to two different tube-voltage/tube-current combinations (80kV p/100mAs and 120kV p/150mAs). The corresponding radiation doses for these protocols are 7.8mSv and 34.3mSV , respectively. The images were reconstructed using conventional FBP and three noise-reduction strengths of the IR method, iDose. Flow contrast-to-noise ratio, CNRf, as obtained from MBF maps, was used to quantitatively evaluate the effect of reconstruction on contrast between normal and ischemic myocardial tissue. Preliminary results showed that the use of iDose to reconstruct low dose images provide better or comparable CNRf to that of high dose images reconstructed with FBP, suggesting significant dose savings. CNRf was improved with the three used levels of iDose compared to FBP for both protocols. When using the entire 4D dynamic sequence for MBF computation, a 77% dose reduction was achieved, while considering only half the scans (i.e., every other heart cycle) allowed even further dose reduction while maintaining relatively higher CNRf.
Picchio, Marcello; Elisei, Walter; Brandimarte, Giovanni; Di Mario, Francesco; Malfertheiner, Peter; Scarpignato, Carmelo; Tursi, Antonio
2016-10-01
Symptomatic uncomplicated diverticular disease (SUDD) is a common gastrointestinal disease, because it affects about one fourth of the patient harboring colonic diverticula. To assess the effectiveness of mesalazine in improving symptoms (namely abdominal pain) and in preventing diverticulitis occurrence in patients with SUDD. Only randomized clinical trials (irrespective of language, blinding, or publication status) that compared mesalazine with placebo or any other therapy in SUDD were evaluated. The selected endpoints were symptom relief and diverticulitis occurrence at maximal follow-up. Absolute risk reduction (ARR, with 95% confidence interval) and the number needed to treat were used as measures of the therapeutic effect. Six randomized clinical trials enrolled 1021 patients: 526 patients were treated with mesalazine and 495 with placebo or other therapies. Symptom relief with mesalazine was always larger than that with placebo and other therapies. However, absolute risk reduction was significant only when mesalazine was compared with placebo, a high-fiber diet, and low-dose rifaximin. The incidence of diverticulitis with mesalazine was lower than that observed with placebo and other treatments, being significant only when compared with placebo. Mesalazine is effective in achieving symptom relief and primary prevention of diverticulitis in patients with SUDD.
Moyanova, S; Kortenska, L; Kirov, R; Iliev, I
1998-12-01
The powerful vasoconstrictor peptide endothelin-1 (ET1) has been shown to reduce local cerebral blood flow in brain areas supplied by the middle cerebral artery (MCA) to a pathologically low level upon intracerebral injection adjacent to the MCA. This reduction manifests itself as an ischemic infarct, that is fully developed within 3 days after ET1 injection. The aim of the present study is to examine the effect of ET1 on electroencephalographic (EEG) activity. ET1 was microinjected unilaterally at a dose of 60 pmol in 3 microl of saline to the MCA in conscious rats. EEG signals were recorded from the frontoparietal cortical area, supplied by MCA, from the first up to the fourteenth day after ET1 injection. EEG activity was analyzed by the fast Fourier transformation. A significant shift to a lower EEG frequency, i.e., augmentation of slow waves and a reduction of alpha-like and faster EEG waves was found post-ET1. This effect was maximal after 3-7 days when the most severe destruction of neurons in this cortical area occurs, as has been previously demonstrated. The results suggest that the quantitative EEG analysis may provide useful additional information about the functional disturbances associated with focal cerebral ischemia.
Method for simulating dose reduction in digital mammography using the Anscombe transformation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borges, Lucas R., E-mail: lucas.rodrigues.borges@usp.br; Oliveira, Helder C. R. de; Nunes, Polyana F.
2016-06-15
Purpose: This work proposes an accurate method for simulating dose reduction in digital mammography starting from a clinical image acquired with a standard dose. Methods: The method developed in this work consists of scaling a mammogram acquired at the standard radiation dose and adding signal-dependent noise. The algorithm accounts for specific issues relevant in digital mammography images, such as anisotropic noise, spatial variations in pixel gain, and the effect of dose reduction on the detective quantum efficiency. The scaling process takes into account the linearity of the system and the offset of the detector elements. The inserted noise is obtainedmore » by acquiring images of a flat-field phantom at the standard radiation dose and at the simulated dose. Using the Anscombe transformation, a relationship is created between the calculated noise mask and the scaled image, resulting in a clinical mammogram with the same noise and gray level characteristics as an image acquired at the lower-radiation dose. Results: The performance of the proposed algorithm was validated using real images acquired with an anthropomorphic breast phantom at four different doses, with five exposures for each dose and 256 nonoverlapping ROIs extracted from each image and with uniform images. The authors simulated lower-dose images and compared these with the real images. The authors evaluated the similarity between the normalized noise power spectrum (NNPS) and power spectrum (PS) of simulated images and real images acquired with the same dose. The maximum relative error was less than 2.5% for every ROI. The added noise was also evaluated by measuring the local variance in the real and simulated images. The relative average error for the local variance was smaller than 1%. Conclusions: A new method is proposed for simulating dose reduction in clinical mammograms. In this method, the dependency between image noise and image signal is addressed using a novel application of the Anscombe transformation. NNPS, PS, and local noise metrics confirm that this method is capable of precisely simulating various dose reductions.« less
Method for simulating dose reduction in digital mammography using the Anscombe transformation
Borges, Lucas R.; de Oliveira, Helder C. R.; Nunes, Polyana F.; Bakic, Predrag R.; Maidment, Andrew D. A.; Vieira, Marcelo A. C.
2016-01-01
Purpose: This work proposes an accurate method for simulating dose reduction in digital mammography starting from a clinical image acquired with a standard dose. Methods: The method developed in this work consists of scaling a mammogram acquired at the standard radiation dose and adding signal-dependent noise. The algorithm accounts for specific issues relevant in digital mammography images, such as anisotropic noise, spatial variations in pixel gain, and the effect of dose reduction on the detective quantum efficiency. The scaling process takes into account the linearity of the system and the offset of the detector elements. The inserted noise is obtained by acquiring images of a flat-field phantom at the standard radiation dose and at the simulated dose. Using the Anscombe transformation, a relationship is created between the calculated noise mask and the scaled image, resulting in a clinical mammogram with the same noise and gray level characteristics as an image acquired at the lower-radiation dose. Results: The performance of the proposed algorithm was validated using real images acquired with an anthropomorphic breast phantom at four different doses, with five exposures for each dose and 256 nonoverlapping ROIs extracted from each image and with uniform images. The authors simulated lower-dose images and compared these with the real images. The authors evaluated the similarity between the normalized noise power spectrum (NNPS) and power spectrum (PS) of simulated images and real images acquired with the same dose. The maximum relative error was less than 2.5% for every ROI. The added noise was also evaluated by measuring the local variance in the real and simulated images. The relative average error for the local variance was smaller than 1%. Conclusions: A new method is proposed for simulating dose reduction in clinical mammograms. In this method, the dependency between image noise and image signal is addressed using a novel application of the Anscombe transformation. NNPS, PS, and local noise metrics confirm that this method is capable of precisely simulating various dose reductions. PMID:27277017
Craven, Meghan; Frank, Graeme R
2018-06-27
Congenital hypothyroidism (CH) is the most common preventable cause of intellectual disability. The recommended starting dose of levothyroxine (LT4) is between 10 and 15 μg/kg, an extremely wide range. We hypothesized that a sizable proportion of newborns treated for CH at the higher end of the dosage range become biochemically hyperthyroid at a follow-up visit. This study is a retrospective chart review of infants with CH between 2002 and 2012. Of the 104 patients included in this analysis, the average age at diagnosis was 11 days and the average starting dose of LT4 was 12±2.5 μg/kg. At follow-up, 36.5% required a dose reduction because of iatrogenic hyperthyroxinemia, 51% required no dose adjustment and 12.5% required a dose increase due to an elevated thyroid stimulating hormone (TSH). The starting doses of LT4 for those requiring a dose reduction, those not requiring an adjustment and those requiring an increase in the dose were 13.2±2.4, 11.5±2.1 and 10.3±2.6 μg/kg/day, respectively (p≤0.0001). Of the 34% of infants treated with an initial dose of >12.5 μg/day, 57.1% required a dose reduction at follow-up, compared to 26.1% of those whose initial starting dose was ≤12.5 μg/kg/day (p=0.007). Following the guidelines for initiating therapy for CH, 36.5% of the infants required a dose reduction for iatrogenic hyperthyroxinemia. These infants received a higher dose of LT4 than the infants who either required no adjustment or required an increase in the dose. A narrower range for initial dosing in CH may be appropriate.
Wang, Bin; Chen, Shouming; Yang, Jun; Yang, Linghui; Liu, Jin; Zhang, Wensheng
2017-01-01
ET-26 HCl is a promising sedative-hypnotic anesthetic with virtually no effect on adrenocortical steroid synthesis. However, whether or not ET-26 HCl also has a sufficiently wide safety margin and hemodynamic stability similar to that of etomidate and related compounds remains unknown. In this study, the effects of ET-26 HCl, etomidate and propofol on therapeutic index, heart rate (HR), mean arterial pressure (MAP), maximal rate for left ventricular pressure rise (Dmax/t), and maximal rate for left ventricular pressure decline (Dmin/t) were investigated in healthy rats and a rat model of uncontrolled hemorrhagic shock (UHS). 50% effective dose (ED50) and 50% lethal dose (LD50) were determined after single bolus doses of propofol, etomidate, or ET-26 HCl using the Bliss method and the up and down method, respectively. All rats were divided into either the normal group and received either etomidate, ET-26 HCl or propofol, (n = 6 per group) or the UHS group and received either etomidate, ET-26 HCl or propofol, (n = 6 per group). In the normal group, after preparation for hemodynamic and heart-function monitoring, rats were administered a dose of one of the test agents twofold-higher than the established ED50, followed by hemodynamic and heart-function monitoring. Rats in the UHS group underwent experimentally induced UHS with a target arterial pressure of 40 mmHg for 1 hour, followed by administration of an ED50 dose of one of the experimental agents. Blood-gas analysis was conducted on samples obtained during equilibration with the experimental setup and at the end of the experiment. In the normal group, no significant differences in HR, MAP, Dmax/t and Dmin/t (all P > 0.05) were observed at any time point between the etomidate and ET-26 HCl groups, whereas HR, MAP and Dmax/t decreased briefly and Dmin/t increased following propofol administration. In the UHS group, no significant differences in HR, MAP, Dmax/t and Dmin/t were observed before and after administration of etomidate or ET-26 HCl at ED50 doses (all P > 0.05). Administration of propofol resulted in brief, statistically significant reductions in HR and Dmax/t, with a brief increase in Dmin/t (P ˂ 0.05), while no significant differences in MAP were observed among the three groups. The blood-lactate concentrations of rats in the ET-26 HCl group were significantly lower than those in etomidate and propofol groups (P ˂ 0.05). ET-26 HCl provides a similar level of hemodynamic stability to that obtained with etomidate in both healthy rats, and rat models of UHS. ET-26 HCl has the potential to be a novel induction anesthetic for use in critically ill patients.
Superior sulcus non-small cell lung carcinoma: A comparison of IMRT and 3D-RT dosimetry.
Truntzer, Pierre; Antoni, Delphine; Santelmo, Nicola; Schumacher, Catherine; Falcoz, Pierre-Emmanuel; Quoix, Elisabeth; Massard, Gilbert; Noël, Georges
2016-01-01
A dosimetric study comparing intensity modulated radiotherapy (IMRT) by TomoTherapy to conformational 3D radiotherapy (3D-RT) in patients with superior sulcus non-small cell lung cancer (NSCLC). IMRT became the main technique in modern radiotherapy. However it was not currently used for lung cancers. Because of the need to increase the dose to control lung cancers but because of the critical organs surrounding the tumors, the gains obtainable with IMRT is not still demonstrated. A dosimetric comparison of the planned target and organs at risk parameters between IMRT and 3D-RT in eight patients who received preoperative or curative intent irradiation. In the patients who received at least 66 Gy, the mean V95% was significantly better with IMRT than 3D-RT (p = 0.043). IMRT delivered a lower D2% compared to 3D-RT (p = 0.043). The IH was significantly better with IMRT (p = 0.043). The lung V 5 Gy and V 13 Gy were significantly higher in IMRT than 3D-RT (p = 0.043), while the maximal dose (D max) to the spinal cord was significantly lower in IMRT (p = 0.043). The brachial plexus D max was significantly lower in IMRT than 3D-RT (p = 0.048). For patients treated with 46 Gy, no significant differences were found. Our study showed that IMRT is relevant for SS-NSCLC. In patients treated with a curative dose, it led to a reduction of the exposure of critical organs, allowing a better dose distribution in the tumor. For the patients treated with a preoperative schedule, our results provide a basis for future controlled trials to improve the histological complete response by increasing the radiation dose.
Karpov, Yuri Aleksandrovich
2017-02-01
Blood pressure (BP) control in hypertensive patients remains poor worldwide, particularly in high-risk patients with hypertension and diabetes. Guidelines recommend that such patients receive prompt pharmacological therapy at maximal doses to rapidly control BP. We aimed to evaluate efficacy and safety of single-pill combination (SPC) perindopril/indapamide (PER/IND) at full dose (10/2.5 mg) in hypertensive patients, including diabetics, with BP uncontrolled by previous medication. Twelve-week prospective, observational study in patients with uncontrolled hypertension (≥160-200 mmHg systolic BP [SBP] and <110 mmHg diastolic BP [DBP]) on a previous SPC or free-dose combination of renin-angiotensin system blocker plus thiazide diuretic, substituted with PER/IND 10/2.5 mg. Office BP, quality of life, and blood parameters were evaluated in the whole cohort and patients with type 2 diabetes mellitus. 2120 ambulatory hypertensive patients were enrolled, including 307 with type 2 diabetes. Two weeks after substitution, SBP significantly decreased from 171.0 ± 13.3 to 148.6 ± 13.4 mmHg, and DBP from 98.6 ± 8.3 to 88.8 ± 7.9 mmHg (both p < 0.00001). A similar rapid decrease was noted in the diabetes subgroup. After 12 weeks, BP had reduced by 42/19 mmHg in the whole cohort (diabetes subgroup: 41/18 mmHg). Most (84%; diabetes subgroup: 77%) patients reached BP target (<140/90 mmHg). Laboratory tests and quality of life improved in the whole cohort and the diabetic subgroup. Switching to PER/IND at full dose (10/2.5 mg) was well tolerated, leading to fast BP reduction and control in the majority of patients with uncontrolled hypertension, including difficult-to-treat patients with diabetes.
Demb, Joshua; Chu, Philip; Nelson, Thomas; Hall, David; Seibert, Anthony; Lamba, Ramit; Boone, John; Krishnam, Mayil; Cagnon, Christopher; Bostani, Maryam; Gould, Robert; Miglioretti, Diana; Smith-Bindman, Rebecca
2017-06-01
Radiation doses for computed tomography (CT) vary substantially across institutions. To assess the impact of institutional-level audit and collaborative efforts to share best practices on CT radiation doses across 5 University of California (UC) medical centers. In this before/after interventional study, we prospectively collected radiation dose metrics on all diagnostic CT examinations performed between October 1, 2013, and December 31, 2014, at 5 medical centers. Using data from January to March (baseline), we created audit reports detailing the distribution of radiation dose metrics for chest, abdomen, and head CT scans. In April, we shared reports with the medical centers and invited radiology professionals from the centers to a 1.5-day in-person meeting to review reports and share best practices. We calculated changes in mean effective dose 12 weeks before and after the audits and meeting, excluding a 12-week implementation period when medical centers could make changes. We compared proportions of examinations exceeding previously published benchmarks at baseline and following the audit and meeting, and calculated changes in proportion of examinations exceeding benchmarks. Of 158 274 diagnostic CT scans performed in the study period, 29 594 CT scans were performed in the 3 months before and 32 839 CT scans were performed 12 to 24 weeks after the audit and meeting. Reductions in mean effective dose were considerable for chest and abdomen. Mean effective dose for chest CT decreased from 13.2 to 10.7 mSv (18.9% reduction; 95% CI, 18.0%-19.8%). Reductions at individual medical centers ranged from 3.8% to 23.5%. The mean effective dose for abdominal CT decreased from 20.0 to 15.0 mSv (25.0% reduction; 95% CI, 24.3%-25.8%). Reductions at individual medical centers ranged from 10.8% to 34.7%. The number of CT scans that had an effective dose measurement that exceeded benchmarks was reduced considerably by 48% and 54% for chest and abdomen, respectively. After the audit and meeting, head CT doses varied less, although some institutions increased and some decreased mean head CT doses and the proportion above benchmarks. Reviewing institutional doses and sharing dose-optimization best practices resulted in lower radiation doses for chest and abdominal CT and more consistent doses for head CT.
Is sympathetic neural vasoconstriction blunted in the vascular bed of exercising human muscle?
Tschakovsky, Michael E; Sujirattanawimol, Kittiphong; Ruble, Stephen B; Valic, Zoran; Joyner, Michael J
2002-06-01
Sympathetic vasoconstriction of muscle vascular beds is important in the regulation of systemic blood pressure. However, vasoconstriction during exercise can also compromise blood flow support of muscle metabolism. This study tested the hypothesis that local factors in exercising muscle blunt vessel responsiveness to sympathetic vasoconstriction. We performed selective infusions of three doses of tyramine into the brachial artery (n = 8) to evoke endogenous release of noradrenaline (norepinephrine) at rest and during moderate and heavy rhythmic handgrip exercise. In separate experiments, tyramine was administered during two doses of adenosine infusion (n = 7) and two doses of sodium nitroprusside (SNP) infusion (n = 8). Vasoconstrictor effectiveness across conditions was assessed as the percentage reduction in forearm vascular conductance (FVC), calculated from invasive blood pressure and non-invasive Doppler ultrasound blood flow measurements at the brachial artery. Tyramine evoked a similar dose-dependent vasoconstriction at rest in all three groups, with the highest dose resulting in a 42-46 % reduction in FVC. This vasoconstriction was blunted with increasing exercise intensity (e.g. tyramine high dose percentage reduction in FVC; rest -43.4 +/- 3.7 %, moderate exercise -27.5 +/- 2.3 %, heavy exercise -16.7 +/- 3.6 %; P < 0.05). In contrast, tyramine infusion resulted in a greater percentage reduction in FVC during both doses of adenosine vs. rest (P < 0.05). Finally, percentage change in FVC was greater during low dose SNP infusion vs. rest (P < 0.05), but not different from rest at the high dose of SNP infusion (P = 0.507). A blunted percentage reduction in FVC during endogenous noradrenaline release in exercise but not vasodilator infusion indicates that sympathetic vasoconstriction is blunted in exercising muscle. This blunting appears to be exercise intensity-dependent.
Prevention of Human Mammary Carcinogenesis
1995-06-30
selected naturally-occurring agents (-)- epigallocatechin gallate ( EGCG ), indole-3-carbinol (13C) and genistein (GEN) for growth inhibition of 184-B5...mechanisms of BP-induced and GEN-induced alterations in cell cycle are being investigated in the ongoing studies. In addition, effects of 13C and EGCG are...rodent mammary tumorigenesis. The maximally nontoxic doses of EGCG , 13C and GEN identified by initial dose-response experiments, were used. The data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saini, Amarjit S.; Zhang, Geoffrey G., E-mail: geoffrey.zhang@moffitt.org; Finkelstein, Steven E.
2011-07-15
Purpose: Vaginal balloon packing is a means to displace organs at risk during high dose rate brachytherapy of the uterine cervix. We tested the hypothesis that contrast-filled vaginal balloon packing reduces radiation dose to organs at risk, such as the bladder and rectum, in comparison to water- or air-filled balloons. Methods and Materials: In a phantom study, semispherical vaginal packing balloons were filled with air, saline solution, and contrast agents. A high dose rate iridium-192 source was placed on the anterior surface of the balloon, and the diode detector was placed on the posterior surface. Dose ratios were taken withmore » each material in the balloon. Monte Carlo (MC) simulations, by use of the MC computer program DOSXYZnrc, were performed to study dose reduction vs. balloon size and contrast material, including commercially available iodine- and gadolinium-based contrast agents. Results: Measured dose ratios on the phantom with the balloon radius of 3.4 cm were 0.922 {+-} 0.002 for contrast/saline solution and 0.808 {+-} 0.001 for contrast/air. The corresponding ratios by MC simulations were 0.895 {+-} 0.010 and 0.781 {+-} 0.010. The iodine concentration in the contrast was 23.3% by weight. The dose reduction of contrast-filled balloon ranges from 6% to 15% compared with water-filled balloon and 11% to 26% compared with air-filled balloon, with a balloon size range between 1.4 and 3.8 cm, and iodine concentration in contrast of 24.9%. The dose reduction was proportional to the contrast agent concentration. The gadolinium-based contrast agents showed less dose reduction because of much lower concentrations in their solutions. Conclusions: The dose to the posterior wall of the bladder and the anterior wall of the rectum can be reduced if the vaginal balloon is filled with contrast agent in comparison to vaginal balloons filled with saline solution or air.« less
Ultralow Dose MSCT Imaging in Dental Implantology
Widmann, Gerlig; Al-Ekrish, Asma'a A.
2018-01-01
Introduction: The Council Directive 2013/59 Euratom has a clear commitment for keeping medical radiation exposure as low as reasonably achievable and demands a regular review and use of diagnostic reference levels. Methods: In dental implantology, the range of effective doses for cone beam computed tomography (CBCT) shows a broad overlap with multislice computed tomography (MSCT). More recently, ultralow dose imaging with new generations of MSCT scanners may impart radiation doses equal to or lower than CBCT. Dose reductions in MSCT have been further facilitated by the introduction of iterative image reconstruction technology (IRT), which provides substantial noise reduction over the current standard of filtered backward projection (FBP). Aim: The aim of this article is to review the available literature on ultralow dose CT imaging and IRTs in dental implantology imaging and to summarize their influence on spatial and contrast resolution, image noise, tissue density measurements, and validity of linear measurements of the jaws. Conclusion: Application of ultralow dose MSCT with IRT technology in dental implantology offers the potential for very large dose reductions compared with standard dose imaging. Yet, evaluation of various diagnostic tasks related to dental implantology is still needed to confirm the results obtained with various IRTs and ultra-low doses so far. PMID:29492174
Responses of pink salmon to CO2-induced aquatic acidification
NASA Astrophysics Data System (ADS)
Ou, Michelle; Hamilton, Trevor J.; Eom, Junho; Lyall, Emily M.; Gallup, Joshua; Jiang, Amy; Lee, Jason; Close, David A.; Yun, Sang-Seon; Brauner, Colin J.
2015-10-01
Ocean acidification negatively affects many marine species and is predicted to cause widespread changes to marine ecosystems. Similarly, freshwater ecosystems may potentially be affected by climate-change-related acidification; however, this has received far less attention. Freshwater fish represent 40% of all fishes, and salmon, which rear and spawn in freshwater, are of immense ecosystem, economical and cultural importance. In this study, we investigate the impacts of CO2-induced acidification during the development of pink salmon, in freshwater and following early seawater entry. At this critical and sensitive life stage, we show dose-dependent reductions in growth, yolk-to-tissue conversion and maximal O2 uptake capacity; as well as significant alterations in olfactory responses, anti-predator behaviour and anxiety under projected future increases in CO2 levels. These data indicate that future populations of pink salmon may be at risk without mitigation and highlight the need for further studies on the impact of CO2-induced acidification on freshwater systems.
Recalcitrant carbohydrates after enzymatic hydrolysis of pretreated lignocellulosic biomass.
Alcántara, María Ángeles Bermúdez; Dobruchowska, Justyna; Azadi, Parastoo; García, Bruno Díez; Molina-Heredia, Fernando P; Reyes-Sosa, Francisco Manuel
2016-01-01
To reduce the cost of the enzymes for the hydrolysis of lignocellulosic biomass, two main strategies have been followed: one, the reduction of enzyme dosing by the use of more efficient and stable enzymatic cocktails; another, to include accessory enzymes in the cocktails to increase yields by reducing the recalcitrant carbohydrate fraction remaining at the end of the process. To guide this second strategy, we have explored the chemical bond composition of different fractions of recalcitrant carbohydrates after enzymatic hydrolysis. Two lignocellulosic feedstocks of relevance for the biofuels industry have been analyzed, corn stover and sugarcane straw. On comparing the composition of chemical bonds of the starting pretreated material with samples after standard and forced hydrolysis (with enzyme overdosing), we obtained similar sugar and chemical bond composition. This suggests that the current enzymatic cocktails bear the set of enzymes needed to hydrolyze these feedstocks. From our point of view, the results show the need for a parallel fine-tuning of the enzymatic cocktails with the pretreatment process to maximize sugar release yield.
New therapeutic principles in dyslipidaemia: focus on LDL and Lp(a) lowering drugs
Norata, Giuseppe Danilo; Ballantyne, Christie M.; Catapano, Alberico Luigi
2013-01-01
Dyslipidaemias play a key role in determining cardiovascular risk; the discovery of statins has contributed a very effective approach. However, many patients do not achieve, at the maximal tolerated dose, the recommended goals for low-density lipoprotein-cholesterol (LDL-C), non-high-density lipoprotein-cholesterol, and apolipoprotein B (apoB). Available agents combined with statins can provide additional LDL-C reduction, and agents in development will increase therapeutic options impacting also other atherogenic lipoprotein classes. In fact, genetic insights into mechanisms underlying regulation of LDL-C levels has expanded potential targets of drug therapy and led to the development of novel agents. Among them are modulators of apoB containing lipoproteins production and proprotein convertase subtilisin/kexin type-9 inhibitors. Alternative targets such as lipoprotein(a) also require attention; however, until we have a better understanding of these issues, further LDL-C lowering in high and very high-risk patients will represent the most sound clinical approach. PMID:23509227
Crooke, Stanley T; Geary, Richard S
2013-01-01
Mipomersen is a second generation antisense oligonucleotide that targets apolipoprotein B. It has been studied thoroughly in clinical trials (more than 800 subjects), including four randomized double-blind placebo controlled phase 3 studies involving 391 patients, and is in registration for the treatment of severe hypercholesterolaemia. The pharmacokinetic and pharmacodynamic properties of mipomersen are well characterized. Mipomersen is rapidly and extensively absorbed after subcutaneous administration and has an elimination half-life of approximately 30 days across species. It is cleared by nuclease metabolism and renal excretion of the metabolites. Mipomersen reduces all apolipoprotein B containing atherogenic particles and displays dose dependent reductions between 50–400 mg week−1, both as a single agent and in the presence of maximal lipid lowering therapy. No drug–drug interactions have been identified. Mipomersen is a representative of second generation antisense drugs, all of which have similar properties, and is thus representative of the behaviour of the class of drugs. PMID:23013161
Garin, Etienne; Rolland, Yan; Laffont, Sophie; Edeline, Julien
2016-03-01
Radioembolization with (90)Y-loaded microspheres is increasingly used in the treatment of primary and secondary liver cancer. Technetium-99 m macroaggregated albumin (MAA) scintigraphy is used as a surrogate of microsphere distribution to assess lung or digestive shunting prior to therapy, based on tumoral targeting and dosimetry. To date, this has been the sole pre-therapeutic tool available for such evaluation. Several dosimetric approaches have been described using both glass and resin microspheres in hepatocellular carcinoma (HCC) and liver metastasis. Given that each product offers different specific activities and numbers of spheres injected, their radiobiological properties are believed to lightly differ. This paper summarizes and discusses the available studies focused on MAA-based dosimetry, particularly concentrating on potential confounding factors like clinical context, tumor size, cirrhosis, previous or concomitant therapy, and product used. In terms of the impact of tumoral dose in HCC, the results were concordant and a response relationship and tumoral threshold dose was clearly identified, especially in studies using glass microspheres. Tumoral dose has also been found to influence survival. The concept of treatment intensification has recently been introduced, yet despite several studies publishing interesting findings on the tumor dose-metastasis relationship, no consensus has been reached, and further clarification is thus required. Nor has the maximal tolerated dose to the liver been well documented, requiring more accurate evaluation. Lung dose was well described, despite recently identified factors influencing its evaluation, requiring further assessment. Conclusion: MAA SPECT/CT dosimetry is accurate in HCC and can now be used in order to achieve a fully customized approach, including treatment intensification. Yet further studies are warranted for the metastasis setting and evaluating the maximal tolerated liver dose.
Determination of the efficiency of commercially available dose calibrators for beta-emitters.
Valley, Jean-François; Bulling, Shelley; Leresche, Michel; Wastiel, Claude
2003-03-01
The goals of this investigation are to determine whether commercially available dose calibrators can be used to measure the activity of beta-emitting radionuclides used in pain palliation and to establish whether manufacturer-supplied calibration factors are appropriate for this purpose. Six types of commercially available dose calibrators were studied. Dose calibrator response was controlled for 5 gamma-emitters used for calibration or typically encountered in routine use. For the 4 most commonly used beta-emitters ((32)P, (90)Sr, (90)Y, and (169)Er) dose calibrator efficiency was determined in the syringe geometry used for clinical applications. Efficiency of the calibrators was also measured for (153)Sm and (186)Re, 2 beta-emitters with significant gamma-contributions. Source activities were traceable to national standards. All calibrators measured gamma-emitters with a precision of +/-10%, in compliance with Swiss regulatory requirements. For beta-emitters, dose calibrator intrinsic efficiency depends strongly on the maximal energy of the beta-spectrum and is notably low for (169)Er. Manufacturer-supplied calibration factors give accurate results for beta-emitters with maximal beta-energy in the middle-energy range (1 MeV) but are not appropriate for use with low-energy ((169)Er) or high-energy ((90)Y) beta-emitters. beta-emitters with significant gamma-contributions behave like gamma-emitters. Commercially available dose calibrators have an intrinsic efficiency that is sufficient for the measurement of beta-emitters, including beta-emitters with a low maximum beta-energy. Manufacturer-supplied calibration factors are reliable for gamma-emitters and beta-emitters in the middle-energy range. For low- and high-energy beta-emitters, the use of manufacturer-supplied calibration factors introduces significant measurement inaccuracy.
NASA Astrophysics Data System (ADS)
Liu, GaiYun; Chao, Daniel Yuh
2015-08-01
To date, research on the supervisor design for flexible manufacturing systems focuses on speeding up the computation of optimal (maximally permissive) liveness-enforcing controllers. Recent deadlock prevention policies for systems of simple sequential processes with resources (S3PR) reduce the computation burden by considering only the minimal portion of all first-met bad markings (FBMs). Maximal permissiveness is ensured by not forbidding any live state. This paper proposes a method to further reduce the size of minimal set of FBMs to efficiently solve integer linear programming problems while maintaining maximal permissiveness using a vector-covering approach. This paper improves the previous work and achieves the simplest structure with the minimal number of monitors.
Effect of Elastase-induced Emphysema on the Force-generating Ability of the Diaphragm
Supinski, Gerald S.; Kelsen, Steven G.
1982-01-01
The effect of emphysema on the ability of the diaphragm to generate force was examined in costal diaphragm muscle strips from 10 Golden hamsters killed 18 mo after intratracheal injection of pancreatic elastase in a dose producing hyperinflation (mean total lung capacity [TLC] = 163% of control) and generalized panacinar emphysema. 13 saline-injected normal animals served as controls. The time course of isometric tension and the effect of alterations in muscle fiber and sarcomere length on the isometric tension (T) generated in response to tetanizing electrical stimuli (length-tension [L-T] relationship) were examined. Elastase administration caused an increase in diaphragm muscle thickness and reduction in the length of costal diaphragm muscle fibers measured in situ. Emphysema significantly increased the maximum tetanic tension as a result of hypertrophy. Maximal tension corrected for increases in muscle cross-sectional area (T/cm2), however, was the same in emphysematous (E) and control (C) animals. Emphysema also shifted the muscle fiber L-T curve of the diaphragm but not of a control muscle, the soleus, toward shorter lengths. In contrast to the effects of E on the diaphragm muscle fiber L-T curve, the sarcomere L-T curve was the same in E and C. Since the length at which tension was maximal correlated closely with sarcomere number (r = 0.94; P < 0.001) reduction in the number of sarcomeres in series in muscles from emphysematous animals appeared to explain the shift in the muscle fiber L-T curve. We conclude that in elastase-induced emphysema adaptive changes both in diaphragm cross-sectional area and sarcomere number augment the force-generating ability of the diaphragm. We speculate that changes in sarcomere number compensate for alterations in muscle fiber length resulting from chronic hyperinflation of the thorax, while diaphragmatic muscle hypertrophy represents a response to changes in respiratory load and/or diaphragm configuration (LaPlace relationship). Images PMID:6922866
DOE Office of Scientific and Technical Information (OSTI.GOV)
Merritt, Z; Dave, J; Eschelman, D
Purpose: To investigate the effects of image receptor technology and dose reduction software on radiation dose estimates for most frequently performed fluoroscopically-guided interventional (FGI) procedures at a tertiary health care center. Methods: IRB approval was obtained for retrospective analysis of FGI procedures performed in the interventional radiology suites between January-2011 and December-2015. This included procedures performed using image-intensifier (II) based systems which were subsequently replaced, flat-panel-detector (FPD) based systems which were later upgraded with ClarityIQ dose reduction software (Philips Healthcare) and relatively new FPD system already equipped with ClarityIQ. Post procedure, technologists entered system-reported cumulative air kerma (CAK) and kerma-areamore » product (KAP; only KAP for II based systems) in RIS; these values were analyzed. Data pre-processing included correcting typographical errors and cross-verifying CAK and KAP. The most frequent high and low dose FGI procedures were identified and corresponding CAK and KAP values were compared. Results: Out of 27,251 procedures within this time period, most frequent high and low dose procedures were chemo/immuno-embolization (n=1967) and abscess drainage (n=1821). Mean KAP for embolization and abscess drainage procedures were 260,657, 310,304 and 94,908 mGycm{sup 2}, and 14,497, 15,040 and 6307 mGycm{sup 2} using II-, FPD- and FPD with ClarityIQ- based systems, respectively. Statistically significant differences were observed in KAP values for embolization procedures with respect to different systems but for abscess drainage procedures significant differences were only noted between systems with FPD and FPD with ClarityIQ (p<0.05). Mean CAK reduced significantly from 823 to 308 mGy and from 43 to 21 mGy for embolization and abscess drainage procedures, respectively, in transitioning to FPD systems with ClarityIQ (p<0.05). Conclusion: While transitioning from II- to FPD- based systems was not associated with dose reduction for the most frequently performed FGI procedures, substantial dose reduction was noted with relatively newer systems and dose reduction software.« less
Ellmann, Stephan; Kammerer, Ferdinand; Brand, Michael; Allmendinger, Thomas; May, Matthias S; Uder, Michael; Lell, Michael M; Kramer, Manuel
2016-05-01
The aim of this study was to determine the dose reduction potential of iterative reconstruction (IR) algorithms in computed tomography angiography (CTA) of the circle of Willis using a novel method of evaluating the quality of radiation dose-reduced images. This study relied on ReconCT, a proprietary reconstruction software that allows simulating CT scans acquired with reduced radiation dose based on the raw data of true scans. To evaluate the performance of ReconCT in this regard, a phantom study was performed to compare the image noise of true and simulated scans within simulated vessels of a head phantom. That followed, 10 patients scheduled for CTA of the circle of Willis were scanned according to our institute's standard protocol (100 kV, 145 reference mAs). Subsequently, CTA images of these patients were reconstructed as either a full-dose weighted filtered back projection or with radiation dose reductions down to 10% of the full-dose level and Sinogram-Affirmed Iterative Reconstruction (SAFIRE) with either strength 3 or 5. Images were marked with arrows pointing on vessels of different sizes, and image pairs were presented to observers. Five readers assessed image quality with 2-alternative forced choice comparisons. In the phantom study, no significant differences were observed between the noise levels of simulated and true scans in filtered back projection, SAFIRE 3, and SAFIRE 5 reconstructions.The dose reduction potential for patient scans showed a strong dependence on IR strength as well as on the size of the vessel of interest. Thus, the potential radiation dose reductions ranged from 84.4% for the evaluation of great vessels reconstructed with SAFIRE 5 to 40.9% for the evaluation of small vessels reconstructed with SAFIRE 3. This study provides a novel image quality evaluation method based on 2-alternative forced choice comparisons. In CTA of the circle of Willis, higher IR strengths and greater vessel sizes allowed higher degrees of radiation dose reduction.
Robust 2DPCA with non-greedy l1 -norm maximization for image analysis.
Wang, Rong; Nie, Feiping; Yang, Xiaojun; Gao, Feifei; Yao, Minli
2015-05-01
2-D principal component analysis based on l1 -norm (2DPCA-L1) is a recently developed approach for robust dimensionality reduction and feature extraction in image domain. Normally, a greedy strategy is applied due to the difficulty of directly solving the l1 -norm maximization problem, which is, however, easy to get stuck in local solution. In this paper, we propose a robust 2DPCA with non-greedy l1 -norm maximization in which all projection directions are optimized simultaneously. Experimental results on face and other datasets confirm the effectiveness of the proposed approach.
Verhoeven, Rozemarijn S; Garcia, Andres; Robeson, RiLee; Gilger, Brian C; Culp, David; Struble, Craig; Hamm, Lee; Navratil, Tomas; Yerxa, Benjamin
Topical corticosteroids are widely used in the treatment of inflammation and pain after ocular surgery, but they possess several shortcomings, including frequent dosing and low patient adherence. We evaluated the efficacy and pharmacokinetics of ENV905 (difluprednate or DFBA) Ophthalmic Implant, a single-dose drug delivery system, compared with 0.05% Durezol. PRINT ® technology was used to fabricate ENV905 implants for either intracameral (IC) or subconjunctival (SCJ) delivery of extended-release DFBA. A postoperative inflammation model and ocular pharmacokinetics studies of ENV905 or Durezol were conducted in albino rabbits for a maximum of 12 weeks. Suppression of ocular inflammation was marked for both IC and SJC ENV905 compared with placebo, and it was superior or equivalent to that observed with QID Durezol. Concentrations of desacetyl difluprednate (DFB, active metabolite) peaked on day 1 and tapered over time for ENV905, with IC ENV905 delivering DFB to the target tissue at the time of greatest inflammation, whereas SJC produced a longer duration of exposure. Durezol eyes demonstrated consistent exposure over time with maximal exposure in the cornea. Although the pharmacokinetic profile differed for the two routes, efficacy was similar. ENV905 was well tolerated and demonstrated a robust reduction in ocular inflammation with targeted drug delivery. The results from these studies show that ENV905 provides a sustained therapeutic effect after a single dose. By resolving low patient compliance and eliminating the peaks and troughs in drug concentration, sustained drug delivery via ENV905 may further improve the overall control of postoperative inflammation and pain.
Circadian variability of body temperature responses to methamphetamine.
Behrouzvaziri, Abolhassan; Zaretskaia, Maria V; Rusyniak, Daniel E; Zaretsky, Dmitry V; Molkov, Yaroslav I
2018-01-01
Vital parameters of living organisms exhibit circadian rhythmicity. Although rats are nocturnal animals, most of the studies involving rats are performed during the day. The objective of this study was to examine the circadian variability of the body temperature responses to methamphetamine. Body temperature was recorded in male Sprague-Dawley rats that received intraperitoneal injections of methamphetamine (Meth, 1 or 5 mg/kg) or saline at 10 AM or at 10 PM. The baseline body temperature at night was 0.8°C higher than during the day. Both during the day and at night, 1 mg/kg of Meth induced monophasic hyperthermia. However, the maximal temperature increase at night was 50% smaller than during the daytime. Injection of 5 mg/kg of Meth during the daytime caused a delayed hyperthermic response. In contrast, the same dose at night produced responses with a tendency toward a decrease of body temperature. Using mathematical modeling, we previously showed that the complex dose dependence of the daytime temperature responses to Meth results from an interplay between inhibitory and excitatory drives. In this study, using our model, we explain the suppression of the hyperthermia in response to Meth at night. First, we found that the baseline activity of the excitatory drive is greater at night. It appears partially saturated and thus is additionally activated by Meth to a lesser extent. Therefore, the excitatory component causes less hyperthermia or becomes overpowered by the inhibitory drive in response to the higher dose. Second, at night the injection of Meth results in reduction of the equilibrium body temperature, leading to gradual cooling counteracting hyperthermia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlson, David J., E-mail: david.j.carlson@yale.ed; Yale University School of Medicine, Department of Therapeutic Radiology, New Haven, CT; Keall, Paul J.
2011-03-15
Purpose: Tumor hypoxia has been observed in many human cancers and is associated with treatment failure in radiation therapy. The purpose of this study is to quantify the effect of different radiation fractionation schemes on tumor cell killing, assuming a realistic distribution of tumor oxygenation. Methods and Materials: A probability density function for the partial pressure of oxygen in a tumor cell population is quantified as a function of radial distance from the capillary wall. Corresponding hypoxia reduction factors for cell killing are determined. The surviving fraction of a tumor consisting of maximally resistant cells, cells at intermediate levels ofmore » hypoxia, and normoxic cells is calculated as a function of dose per fraction for an equivalent tumor biological effective dose under normoxic conditions. Results: Increasing hypoxia as a function of distance from blood vessels results in a decrease in tumor cell killing for a typical radiotherapy fractionation scheme by a factor of 10{sup 5} over a distance of 130 {mu}m. For head-and-neck cancer and prostate cancer, the fraction of tumor clonogens killed over a full treatment course decreases by up to a factor of {approx}10{sup 3} as the dose per fraction is increased from 2 to 24 Gy and from 2 to 18 Gy, respectively. Conclusions: Hypofractionation of a radiotherapy regimen can result in a significant decrease in tumor cell killing compared to standard fractionation as a result of tumor hypoxia. There is a potential for large errors when calculating alternate fractionations using formalisms that do not account for tumor hypoxia.« less
NASA Astrophysics Data System (ADS)
Angel, Erin; Yaghmai, Nazanin; Matilda Jude, Cecilia; DeMarco, John J.; Cagnon, Christopher H.; Goldin, Jonathan G.; Primak, Andrew N.; Stevens, Donna M.; Cody, Dianna D.; McCollough, Cynthia H.; McNitt-Gray, Michael F.
2009-02-01
Tube current modulation was designed to reduce radiation dose in CT imaging while maintaining overall image quality. This study aims to develop a method for evaluating the effects of tube current modulation (TCM) on organ dose in CT exams of actual patient anatomy. This method was validated by simulating a TCM and a fixed tube current chest CT exam on 30 voxelized patient models and estimating the radiation dose to each patient's glandular breast tissue. This new method for estimating organ dose was compared with other conventional estimates of dose reduction. Thirty detailed voxelized models of patient anatomy were created based on image data from female patients who had previously undergone clinically indicated CT scans including the chest area. As an indicator of patient size, the perimeter of the patient was measured on the image containing at least one nipple using a semi-automated technique. The breasts were contoured on each image set by a radiologist and glandular tissue was semi-automatically segmented from this region. Previously validated Monte Carlo models of two multidetector CT scanners were used, taking into account details about the source spectra, filtration, collimation and geometry of the scanner. TCM data were obtained from each patient's clinical scan and factored into the model to simulate the effects of TCM. For each patient model, two exams were simulated: a fixed tube current chest CT and a tube current modulated chest CT. X-ray photons were transported through the anatomy of the voxelized patient models, and radiation dose was tallied in the glandular breast tissue. The resulting doses from the tube current modulated simulations were compared to the results obtained from simulations performed using a fixed mA value. The average radiation dose to the glandular breast tissue from a fixed tube current scan across all patient models was 19 mGy. The average reduction in breast dose using the tube current modulated scan was 17%. Results were size dependent with smaller patients getting better dose reduction (up to 64% reduction) and larger patients getting a smaller reduction, and in some cases the dose actually increased when using tube current modulation (up to 41% increase). The results indicate that radiation dose to glandular breast tissue generally decreases with the use of tube current modulated CT acquisition, but that patient size (and in some cases patient positioning) may affect dose reduction.
Phase aberration simulation study of MRgFUS breast treatments
Farrer, Alexis I.; Almquist, Scott; Dillon, Christopher R.; Neumayer, Leigh A.; Parker, Dennis L.; Christensen, Douglas A.; Payne, Allison
2016-01-01
Purpose: This simulation study evaluates the effects of phase aberration in breast MR-guided focused ultrasound (MRgFUS) ablation treatments performed with a phased-array transducer positioned laterally to the breast. A quantification of these effects in terms of thermal dose delivery and the potential benefits of phase correction is demonstrated in four heterogeneous breast numerical models. Methods: To evaluate the effects of varying breast tissue properties on the quality of the focus, four female volunteers with confirmed benign fibroadenomas were imaged using 3T MRI. These images were segmented into numerical models with six tissue types, with each tissue type assigned standard acoustic properties from the literature. Simulations for a single-plane 16-point raster-scan treatment trajectory centered in a fibroadenoma in each modeled breast were performed for a breast-specific MRgFUS system. At each of the 16 points, pressure patterns both with and without applying a phase correction technique were determined with the hybrid-angular spectrum method. Corrected phase patterns were obtained using a simulation-based phase aberration correction technique to adjust each element’s transmit phase to obtain maximized constructive interference at the desired focus. Thermal simulations were performed for both the corrected and uncorrected pressure patterns using a finite-difference implementation of the Pennes bioheat equation. The effect of phase correction was evaluated through comparison of thermal dose accumulation both within and outside a defined treatment volume. Treatment results using corrected and uncorrected phase aberration simulations were compared by evaluating the power required to achieve a 20 °C temperature rise at the first treatment location. The extent of the volumes that received a minimum thermal dose of 240 CEM at 43 °C inside the intended treatment volume as well as the volume in the remaining breast tissues was also evaluated in the form of a dose volume ratio (DVR), a DVR percent change between corrected and uncorrected phases, and an additional metric that measured phase spread. Results: With phase aberration correction applied, there was an improvement in the focus for all breast anatomies as quantified by a reduction in power required (13%–102%) to reach 20 °C when compared to uncorrected simulations. Also, the DVR percent change increased by 5%–77% in seven out of eight cases, indicating an improvement to the treatment as measured by a reduction in thermal dose deposited to the nontreatment tissues. Breast compositions with a higher degree of heterogeneity along the ultrasound beam path showed greater reductions in thermal dose delivered outside of the treatment volume with correction applied than beam trajectories that propagated through more homogeneous breast compositions. An increasing linear trend was observed between the DVR percent change and the phase-spread metric (R2 = 0.68). Conclusions: These results indicate that performing phase aberration correction for breast MRgFUS treatments is beneficial for the small-aperture transducer (14.4 × 9.8 cm) evaluated in this work. While all breast anatomies could benefit from phase aberration correction, greater benefits are observed in more heterogeneous anatomies. PMID:26936722
DOE Office of Scientific and Technical Information (OSTI.GOV)
Engberg, L; KTH Royal Institute of Technology, Stockholm; Eriksson, K
Purpose: To formulate objective functions of a multicriteria fluence map optimization model that correlate well with plan quality metrics, and to solve this multicriteria model by convex approximation. Methods: In this study, objectives of a multicriteria model are formulated to explicitly either minimize or maximize a dose-at-volume measure. Given the widespread agreement that dose-at-volume levels play important roles in plan quality assessment, these objectives correlate well with plan quality metrics. This is in contrast to the conventional objectives, which are to maximize clinical goal achievement by relating to deviations from given dose-at-volume thresholds: while balancing the new objectives means explicitlymore » balancing dose-at-volume levels, balancing the conventional objectives effectively means balancing deviations. Constituted by the inherently non-convex dose-at-volume measure, the new objectives are approximated by the convex mean-tail-dose measure (CVaR measure), yielding a convex approximation of the multicriteria model. Results: Advantages of using the convex approximation are investigated through juxtaposition with the conventional objectives in a computational study of two patient cases. Clinical goals of each case respectively point out three ROI dose-at-volume measures to be considered for plan quality assessment. This is translated in the convex approximation into minimizing three mean-tail-dose measures. Evaluations of the three ROI dose-at-volume measures on Pareto optimal plans are used to represent plan quality of the Pareto sets. Besides providing increased accuracy in terms of feasibility of solutions, the convex approximation generates Pareto sets with overall improved plan quality. In one case, the Pareto set generated by the convex approximation entirely dominates that generated with the conventional objectives. Conclusion: The initial computational study indicates that the convex approximation outperforms the conventional objectives in aspects of accuracy and plan quality.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glatard, Anaïs; Berges, Aliénor; Sahota, Tarjinder
The no-observed-adverse-effect level (NOAEL) of a drug defined from animal studies is important for inferring a maximal safe dose in human. However, several issues are associated with its concept, determination and application. It is confined to the actual doses used in the study; becomes lower with increasing sample size or dose levels; and reflects the risk level seen in the experiment rather than what may be relevant for human. We explored a pharmacometric approach in an attempt to address these issues. We first used simulation to examine the behaviour of the NOAEL values as determined by current common practice; andmore » then fitted the probability of toxicity as a function of treatment duration and dose to data collected from all applicable toxicology studies of a test compound. Our investigation was in the context of an irreversible toxicity that is detected at the end of the study. Simulations illustrated NOAEL's dependency on experimental factors such as dose and sample size, as well as the underlying uncertainty. Modelling the probability as a continuous function of treatment duration and dose simultaneously to data from multiple studies allowed the estimation of the dose, along with its confidence interval, for a maximal risk level that might be deemed as acceptable for human. The model-based data integration also reconciled between-study inconsistency and explicitly provided maximised estimation confidence. Such alternative NOAEL determination method should be explored for its more efficient data use, more quantifiable insight to toxic doses, and the potential for more relevant animal-to-human translation. - Highlights: • Simulations revealed issues with NOAEL concept, determination and application. • Probabilistic modelling was used to address these issues. • The model integrated time-dose-toxicity data from multiple studies. • The approach uses data efficiently and may allow more meaningful human translation.« less
Optimization of the temporal pattern of radiation: An IMRT based study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Altman, Michael B.; Chmura, Steven J.; Deasy, Joseph O.
Purpose: To investigate how the temporal pattern of dose applied during a single-intensity modulated radiation therapy (IMRT) fraction can be arranged to maximize or minimize cell kill. Methods and Materials: Using the linear-quadratic repair-time model and a simplified IMRT delivery pattern model, the surviving fraction of cells for a single fraction was calculated for all permutations of the dose delivery pattern for an array of clinically based IMRT cases. Maximization of cell kill was achieved by concentrating the highest doses in the middle of a fraction, while minimization was achieved by spreading the highest doses between the beginning and end.more » The percent difference between maximum and minimum cell kill (%Diff{sub min/max}) and the difference between maximum and minimum total doses normalized to 2 Gy/fx ({delta}NTD{sub 2Gy}) was calculated for varying fraction durations (T), {alpha}/{beta} ratios, and doses/fx. Results: %Diff{sub min/max} and {delta}NTD{sub 2Gy} both increased with increasing T and with decreasing {alpha}/{beta}. The largest increases occurred with dose/fx. With {alpha}/{beta} = 3 Gy and 30 min/fx, %Diff{sub min/max} ranged from 2.7-5.3% for 2 Gy/fx to 48.6-74.1% for 10 Gy/fx, whereas {delta}NTD{sub 2Gy} ranged from 1.2 Gy-2.4 Gy for 30 fractions of 2 Gy/fx to 2.3-4.8 Gy for 2 fractions of 10.84 Gy/fx. Using {alpha}/{beta} = 1.5 Gy, an analysis of prostate hypofractionation schemes yielded differences in clinical outcome based on the pattern of applied dose ranging from 3.2%-6.1% of the treated population. Conclusions: Rearrangement of the temporal pattern of dose for a single IMRT fraction could be used to optimize cell kill and to directly, though modestly, affect treatment outcome.« less
Grebenstein, Patricia; Burroughs, Danielle; Zhang, Yan; LeSage, Mark G
2013-12-01
Reducing the nicotine content in tobacco products is being considered by the FDA as a policy to reduce the addictiveness of tobacco products. Understanding individual differences in response to nicotine reduction will be critical to developing safe and effective policy. Animal and human research demonstrating sex differences in the reinforcing effects of nicotine suggests that males and females may respond differently to nicotine-reduction policies. However, no studies have directly examined sex differences in the effects of nicotine unit-dose reduction on nicotine self-administration (NSA) in animals. The purpose of the present study was to examine this issue in a rodent self-administration model. Male and female rats were trained to self-administer nicotine (0.06mg/kg) under an FR 3 schedule during daily 23h sessions. Rats were then exposed to saline extinction and reacquisition of NSA, followed by weekly reductions in the unit dose (0.03 to 0.00025mg/kg) until extinction levels of responding were achieved. Males and females were compared with respect to baseline levels of intake, resistance to extinction, degree of compensatory increases in responding during dose reduction, and the threshold reinforcing unit dose of nicotine. Exponential demand-curve analysis was also conducted to compare the sensitivity of males and females to increases in the unit price (FR/unit dose) of nicotine (i.e., elasticity of demand or reinforcing efficacy). Females exhibited significantly higher baseline intake and less compensation than males. However, there were no sex differences in the reinforcement threshold or elasticity of demand. Dose-response relationships were very well described by the exponential demand function (r(2) values>0.96 for individual subjects). These findings suggest that females may exhibit less compensatory smoking in response to nicotine reduction policies, even though their nicotine reinforcement threshold and elasticity of demand may not differ from males. Copyright © 2013 Elsevier Inc. All rights reserved.
Evaluating the potential for secondary mass savings in vehicle lightweighting.
Alonso, Elisa; Lee, Theresa M; Bjelkengren, Catarina; Roth, Richard; Kirchain, Randolph E
2012-03-06
Secondary mass savings are mass reductions that may be achieved in supporting (load-bearing) vehicle parts when the gross vehicle mass (GVM) is reduced. Mass decompounding is the process by which it is possible to identify further reductions when secondary mass savings result in further reduction of GVM. Maximizing secondary mass savings (SMS) is a key tool for maximizing vehicle fuel economy. In today's industry, the most complex parts, which require significant design detail (and cost), are designed first and frozen while the rest of the development process progresses. This paper presents a tool for estimating SMS potential early in the design process and shows how use of the tool to set SMS targets early, before subsystems become locked in, maximizes mass savings. The potential for SMS in current passenger vehicles is estimated with an empirical model using engineering analysis of vehicle components to determine mass-dependency. Identified mass-dependent components are grouped into subsystems, and linear regression is performed on subsystem mass as a function of GVM. A Monte Carlo simulation is performed to determine the mean and 5th and 95th percentiles for the SMS potential per kilogram of primary mass saved. The model projects that the mean theoretical secondary mass savings potential is 0.95 kg for every 1 kg of primary mass saved, with the 5th percentile at 0.77 kg/kg when all components are available for redesign. The model was used to explore an alternative scenario where realistic manufacturing and design limitations were implemented. In this case study, four key subsystems (of 13 total) were locked-in and this reduced the SMS potential to a mean of 0.12 kg/kg with a 5th percentile of 0.1 kg/kg. Clearly, to maximize the impact of mass reduction, targets need to be established before subsystems become locked in.
de Arruda, Aline; Cardoso, Claudia Andrea L; Vieira, Maria do Carmo; Arena, Arielle Cristina
2016-01-01
Hibiscus sabdariffa L. (Malvaceae) is a species widely used in folk medicine for the treatment of some disorders. This study evaluated the effects of H. sabdariffa (HS) on the development of the male reproductive tract in rats following in utero exposure. Pregnant rats received 250 or 500 mg/kg of HS extract or vehicle from gestational day 12 until day 21 of lactation. Both doses of HS increased the body weight of male offspring at weaning, without compromising the puberty onset parameters. At puberty, there was a significant increase in the vas deferens absolute weight and a significant reduction in the relative weight of kidney at higher dose. These animals also presented a significant reduction in the sperm number in the caput/corpus of epididymis after exposure to both doses and a reduction in the sperm number in the cauda epididymis for the lower dose. At adulthood, the highest dose significantly reduced the sperm production in relation to controls and both doses provoked a reduction in the relative sperm number in the epididymis without affecting the sperm morphology. These findings demonstrated that maternal exposure to H. sabdariffa can adversely influence the male reproductive system in rats.
Cardiorespiratory deconditioning with static and dynamic leg exercise during bed rest
NASA Technical Reports Server (NTRS)
Stremel, R. W.; Convertino, V. A.; Bernauer, E. M.; Greenleaf, J. E.
1976-01-01
Results are presented for an experimental study designed to compare the effects of heavy static and dynamic exercise training during 14 days of bed rest on the cardiorespiratory responses to submaximal and maximal exercise performed by seven healthy men aged 19-22 yr. The parameters measured were submaximal and maximal oxygen uptake, minute ventilation, heart rate, and plasma volume. The results indicate that exercise alone during bed rest reduces but does not eliminate the reduction in maximal oxygen uptake. An additional positive hydrostatic effect is therefore necessary to restore maximal oxygen uptake to ambulatory control levels. The greater protective effect of static exercise on maximal oxygen uptake is probably due to a greater hydrostatic component from the isometric muscular contraction. Neither the static nor the dynamic exercise training regimes are found to minimize the changes in all the variables studied, thereby suggesting a combination of static and dynamic exercises.
NASA Astrophysics Data System (ADS)
Chung, Jin-Beom; Kim, Jae-Sung; Kim, In-Ah; Lee, Jeong-Woo
2012-10-01
This study is intended to investigate the effects of surface dose from air gaps under the bolus in clinically used oblique photon beams by using a Markus parallel-plate chamber and a metal-oxide semiconductor field-effect transistor (MOSFET) dosimeter. To evaluate the performances of the two detectors, the percentage surface doses of the MOSFET dosimeters in without an air gap under the bolus material were measured and compared with those of the Markus parallel-plate chamber. MOSFET dosimeters at the surface provided results mostly in good agreement with the parallelplate chamber. The MOSFET dosimeters seemed suitable for surface dose measurements having excellent accuracy for clinical used photon beams. The relative surface doses were measured with air gaps (2, 5, 10 mm) and without an air gap under 3 different bolus setups: (1) unbolused (no bolus), (2) 5-mm bolus, and (3) 10-mm bolus. The reductions in the surface dose substantially increased with small field size, thick bolus, and large air gap. The absolute difference in the reductions of the surface dose between the MOSFET dosimeter and the Markus parallel-plate chamber was less than 1.1%. Results at oblique angles of incidence showed larger reductions in surface dose with increasing angle of incidence. The largest reduction in surface dose was recorded for a 6 × 6 cm2 field at a 60° angle of incidence with an 10-mm air gap under a 10-mm bolus. When a 10-mm bolus was used, a reduction in the surface dose with an air gap of up to 10.5% could be achieved by varying the field size and the incident angle. Therefore, air gaps under the bolus should be avoided in radiotherapy treatment, especially for photon beam with highly oblique angles of incidence.
CT breast dose reduction with the use of breast positioning and organ-based tube current modulation.
Fu, Wanyi; Tian, Xiaoyu; Sturgeon, Gregory M; Agasthya, Greeshma; Segars, William Paul; Goodsitt, Mitchell M; Kazerooni, Ella A; Samei, Ehsan
2017-02-01
This study aimed to investigate the breast dose reduction potential of a breast-positioning (BP) technique for thoracic CT examinations with organ-based tube current modulation (OTCM). This study included 13 female anthropomorphic computational phantoms (XCAT, age range: 27-65 y.o., weight range: 52-105.8 kg). Each phantom was modified to simulate three breast sizes in standard supine geometry. The modeled breasts were then morphed to emulate BP that constrained the majority of the breast tissue inside the 120° anterior tube current (mA) reduction zone. The OTCM mA value was modeled using a ray-tracing program, which reduced the mA to 20% in the anterior region with a corresponding increase to the posterior region. The organ doses were estimated by a validated Monte Carlo program for a typical clinical CT system (SOMATOM Definition Flash, Siemens Healthcare). The simulated organ doses and organ doses normalized by CTDI vol were used to compare three CT protocols: attenuation-based tube current modulation (ATCM), OTCM, and OTCM with BP (OTCM BP ). On average, compared to ATCM, OTCM reduced breast dose by 19.3 ± 4.5%, whereas OTCM BP reduced breast dose by 38.6 ± 8.1% (an additional 23.8 ± 9.4%). The dose saving of OTCM BP was more significant for larger breasts (on average 33, 38, and 44% reduction for 0.5, 1, and 2 kg breasts, respectively). Compared to ATCM, OTCM BP also reduced thymus and heart dose by 15.1 ± 7.4% and 15.9 ± 6.2% respectively. In thoracic CT examinations, OTCM with a breast-positioning technique can markedly reduce unnecessary exposure to radiosensitive organs in anterior chest wall, specifically breast tissue. The breast dose reduction is more notable for women with larger breasts. © 2016 American Association of Physicists in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, S; Kim, K; Jung, H
Purpose: This study evaluated usability of Multileaf collimator (MLC) for diagnostic radiation in cephalometric exposure using optical stimulated luminance dosimeters (OSLDs) Methods: The MLC material was made alloy tool steel (SKD-11) and the density of it is 7.89g/m3 that is similar to it of steel (Fe, 7.85 g/m3) and the MLC was attached to general radiography unit (Rex-650R, Listem Inc, Korea) for cephalometric exposure. The OSLDs that used were nanoDotTM Dosimeter (Landauer Inc, Glenwood, USA) and we read out OSLDs with micro star system (Landauer Inc, Glenwood, USA). The Optical annealing system contained fluorescent lamps (Osram lumilux, 24 W, 280more » ∼780 nm). To measure absorbed dose using OSLDs, was carried out dosimetric characteristics of OSLDs. Based on these, we evaluated dose reduction of critical organ (Eyes, Thyroids) with MLC in cephalometric exposure Results: The dosimetric characteristics were following that batch homogeneity was 1.21% and reproducibility was 0.96% of the coefficient of variation The linearity was that the correlation of between dose and count was fitted by linear function (dose,mGy = 0.00029 × Count, R2 =0.997). The range of angular dependence was from −3.6% to 3.7% variation when each degree was normalized by zero degree. The organ dose of Rt. eye, Lt eye, thyroids were 77.8 μGy, 337.0 μGy, 323.1μGy, respectively in open field and the dose reduction of organ dose was 10.6%(8.3μGy), 12.4 %(42 μGy), 87.1%(281.4μGy) with MLC Conclusion: We certified dose reduction of organ dose in cephalometric exposure. The dose reduction of Eye was 11% because of reduction of field size and it of thyroids was 87% by primary beam shielding.« less
Lubner, Meghan G.; Pickhardt, Perry J.; Kim, David H.; Tang, Jie; Munoz del Rio, Alejandro; Chen, Guang-Hong
2014-01-01
Purpose To prospectively study CT dose reduction using the “prior image constrained compressed sensing” (PICCS) reconstruction technique. Methods Immediately following routine standard dose (SD) abdominal MDCT, 50 patients (mean age, 57.7 years; mean BMI, 28.8) underwent a second reduced-dose (RD) scan (targeted dose reduction, 70-90%). DLP, CTDIvol and SSDE were compared. Several reconstruction algorithms (FBP, ASIR, and PICCS) were applied to the RD series. SD images with FBP served as reference standard. Two blinded readers evaluated each series for subjective image quality and focal lesion detection. Results Mean DLP, CTDIvol, and SSDE for RD series was 140.3 mGy*cm (median 79.4), 3.7 mGy (median 1.8), and 4.2 mGy (median 2.3) compared with 493.7 mGy*cm (median 345.8), 12.9 mGy (median 7.9 mGy) and 14.6 mGy (median 10.1) for SD series, respectively. Mean effective patient diameter was 30.1 cm (median 30), which translates to a mean SSDE reduction of 72% (p<0.001). RD-PICCS image quality score was 2.8±0.5, improved over the RD-FBP (1.7±0.7) and RD-ASIR(1.9±0.8)(p<0.001), but lower than SD (3.5±0.5)(p<0.001). Readers detected 81% (184/228) of focal lesions on RD-PICCS series, versus 67% (153/228) and 65% (149/228) for RD-FBP and RD-ASIR, respectively. Mean image noise was significantly reduced on RD-PICCS series (13.9 HU) compared with RD-FBP (57.2) and RD-ASIR (44.1) (p<0.001). Conclusion PICCS allows for marked dose reduction at abdominal CT with improved image quality and diagnostic performance over reduced-dose FBP and ASIR. Further study is needed to determine indication-specific dose reduction levels that preserve acceptable diagnostic accuracy relative to higher-dose protocols. PMID:24943136
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Rachel; Ng, Angela; Constine, Louis S.
Purpose: Survivors of pediatric Hodgkin lymphoma (HL) are recognized to have an increased risk of delayed adverse health outcomes related to radiation therapy (RT). However, the necessary latency required to observe these late effects means that the estimated risks apply to outdated treatments. We sought to compare the normal tissue dose received by children treated for HL and enrolled in the Childhood Cancer Survivor Study (CCSS) (diagnosed 1970-1986) with that of patients treated in recent Children's Oncology Group (COG) trials (enrolled 2002-2012). Methods and Materials: RT planning data were obtained for 50 HL survivors randomly sampled from the CCSS cohortmore » and applied to computed tomography planning data sets to reconstruct the normal tissue dosimetry. For comparison, the normal tissue dosimetry data were obtained for all 191 patients with full computed tomography–based volumetric RT planning on COG protocols AHOD0031 and AHOD0831. Results: For early-stage patients, the mean female breast dose in the COG patients was on average 83.5% lower than that for CCSS patients, with an absolute reduction of 15.5 Gy. For advanced-stage patients, the mean breast dose was decreased on average by 70% (11.6 Gy average absolute dose reduction). The mean heart dose decreased on average by 22.9 Gy (68.6%) and 17.6 Gy (56.8%) for early- and advanced-stage patients, respectively. All dose comparisons for breast, heart, lung, and thyroid were significantly lower for patients in the COG trials than for the CCSS participants. Reductions in the prescribed dose were a major contributor to these dose reductions. Conclusions: These are the first data quantifying the significant reduction in the normal tissue dose using actual, rather than hypothetical, treatment plans for children with HL. These findings provide useful information when counseling families regarding the risks of contemporary RT.« less
Jenkins, David J A; Kendall, Cyril W C; Faulkner, Dorothea; Vidgen, Edward; Trautwein, Elke A; Parker, Tina L; Marchie, Augustine; Koumbridis, George; Lapsley, Karen G; Josse, Robert G; Leiter, Lawrence A; Connelly, Philip W
2002-12-01
Plant sterols, soy proteins, and viscous fibers are advised for cholesterol reduction but their combined effect has never been tested. We therefore assessed their combined effect on blood lipids in hyperlipidemic subjects who were already consuming a low-saturated fat, low-cholesterol diet before starting the study. The test (combination) diet was 1 month in duration and was very low in saturated fat and high in plant sterols (1 g/1,000 kcal), soy protein (23 g/1,000 kcal), and viscous fibers (9 g/1,000 kcal) obtained from foods available in supermarkets and health food stores. One subject also completed 2 further diet periods: a low-fat control diet and a control diet plus 20 mg/d lovastatin. Fasting blood lipids, blood pressure, and body weight were measured prior to and at weekly intervals during the study. The combination diet was rated as acceptable and very filling. The diet reduced low-density lipoprotein (LDL)-cholesterol by 29.0% +/- 2.7% (P <.001) and the ratio of LDL-cholesterol to high-density lipoprotein (HDL)-cholesterol by 26.5% +/- 3.4% (P <.001). Near maximal reductions were seen by week 2. In the subject who took Mevacor and control diets each for 4 weeks, the reduction in LDL:HDL-cholesterol on Mevacor was similar to the combination diet. We conclude that acceptable diets of foods from supermarkets and health food stores that contain recognized cholesterol-lowering dietary components in combination (a dietary portfolio) may be as effective as the starting dose of older first-line drugs in managing hypercholesterolemia. Copyright 2002, Elsevier Science (USA). All rights reserved.
Zhou, Yanling; Li, Guannan; Li, Dan; Cui, Hongmei; Ning, Yuping
2018-05-01
The long-term effects of dose reduction of atypical antipsychotics on cognitive function and symptomatology in stable patients with schizophrenia remain unclear. We sought to determine the change in cognitive function and symptomatology after reducing risperidone or olanzapine dosage in stable schizophrenic patients. Seventy-five stabilized schizophrenic patients prescribed risperidone (≥4 mg/day) or olanzapine (≥10 mg/day) were randomly divided into a dose-reduction group ( n=37) and a maintenance group ( n=38). For the dose-reduction group, the dose of antipsychotics was reduced by 50%; for the maintenance group, the dose remained unchanged throughout the whole study. The Positive and Negative Syndrome Scale, Negative Symptom Assessment-16, Rating Scale for Extrapyramidal Side Effects, and Measurement and Treatment Research to Improve Cognition in Schizophrenia (MATRICS) Consensus Cognitive Battery were measured at baseline, 12, 28, and 52 weeks. Linear mixed models were performed to compare the Positive and Negative Syndrome Scale, Negative Symptom Assessment-16, Rating Scale for Extrapyramidal Side Effects and MATRICS Consensus Cognitive Battery scores between groups. The linear mixed model showed significant time by group interactions on the Positive and Negative Syndrome Scale negative symptoms, Negative Symptom Assessment-16, Rating Scale for Extrapyramidal Side Effects, speed of processing, attention/vigilance, working memory and total score of MATRICS Consensus Cognitive Battery (all p<0.05). Post hoc analyses showed significant improvement in Positive and Negative Syndrome Scale negative subscale, Negative Symptom Assessment-16, Rating Scale for Extrapyramidal Side Effects, speed of processing, working memory and total score of MATRICS Consensus Cognitive Battery for the dose reduction group compared with those for the maintenance group (all p<0.05). This study indicated that a risperidone or olanzapine dose reduction of 50% may not lead to more severe symptomatology but can improve speed of processing, working memory and negative symptoms in patients with stabilized schizophrenia.
Meschke, J S; Sobsey, M D
2003-01-01
Norwalk-like viruses (NLVs) are important agents of waterborne illness and have been linked to several groundwater-related outbreaks. The presence of human enteric viruses, in particular the presence of NLVs, is difficult to detect in the environment. Consequently, surrogate organisms are typically used as indicators of viruses from faecal contamination. Whether traditional bacterial indicators are reliable indicators for viral pathogens remains uncertain. Few studies have directly compared mobility and reduction of bacterial indicators (e.g. coliforms, Escherichia coli) and other surrogate indicators (coliphages) with pathogenic human viruses in soil systems. In this study the mobility and comparative reduction of the prototype NLV, Norwalk Virus (NV), was compared to poliovirus 1 (PV1), a bacterial indicator (E coli, EC) and a viral indicator (coliphage MS2) through miniature soil columns. Replicate, 10 cm deep, miniature columns were prepared using three soils representing a range of soil textures (sand, organic muck, and clay). Columns were initially conditioned, then incubated at 10-14 degrees C, dosed twice weekly for 8 weeks with one column pore volume of virus-seeded groundwater per dose, followed by 8 weeks of dosing with one column pore volume per dose of unseeded, simulated rainwater. Columns were allowed to drain after each dosing until an effluent volume equivalent to an applied dose was collected. Column effluents and doses were assayed for all viruses and EC. Rapid mobility with minimal reduction was observed for all organisms in the sand. Similar reductions were observed in organic muck for most organisms but NV showed a greater reduction. No organisms were shown to pass through the clay columns. Elution of viruses, in particular PV1, from the columns was gradual. After cessation of microbe dosing, E. coli was less detectable than viruses in column effluents and, therefore, unreliable as a virus indicator.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gorn, L.E.
1960-06-01
Results are reported from a study on 45 persons subjected during work to the protracted action of rontgen and gamma rays in doses exceeding the maximal permissible ones. It was found that the creatine, aromatic amino acids, and non- hemoglobin iron, as well as the redox potential of the serum, do not differ from the respective values in healthy subjects. (auth)
Optimizing Preseason Training Loads in Australian Football.
Carey, David L; Crow, Justin; Ong, Kok-Leong; Blanch, Peter; Morris, Meg E; Dascombe, Ben J; Crossley, Kay M
2018-02-01
To investigate whether preseason training plans for Australian football can be computer generated using current training-load guidelines to optimize injury-risk reduction and performance improvement. A constrained optimization problem was defined for daily total and sprint distance, using the preseason schedule of an elite Australian football team as a template. Maximizing total training volume and maximizing Banister-model-projected performance were both considered optimization objectives. Cumulative workload and acute:chronic workload-ratio constraints were placed on training programs to reflect current guidelines on relative and absolute training loads for injury-risk reduction. Optimization software was then used to generate preseason training plans. The optimization framework was able to generate training plans that satisfied relative and absolute workload constraints. Increasing the off-season chronic training loads enabled the optimization algorithm to prescribe higher amounts of "safe" training and attain higher projected performance levels. Simulations showed that using a Banister-model objective led to plans that included a taper in training load prior to competition to minimize fatigue and maximize projected performance. In contrast, when the objective was to maximize total training volume, more frequent training was prescribed to accumulate as much load as possible. Feasible training plans that maximize projected performance and satisfy injury-risk constraints can be automatically generated by an optimization problem for Australian football. The optimization methods allow for individualized training-plan design and the ability to adapt to changing training objectives and different training-load metrics.
Influence of feedstock particle size on lignocellulose conversion--a review.
Vidal, Bernardo C; Dien, Bruce S; Ting, K C; Singh, Vijay
2011-08-01
Feedstock particle sizing can impact the economics of cellulosic ethanol commercialization through its effects on conversion yield and energy cost. Past studies demonstrated that particle size influences biomass enzyme digestibility to a limited extent. Physical size reduction was able to increase conversion rates to maximum of ≈ 50%, whereas chemical modification achieved conversions of >70% regardless of biomass particle size. This suggests that (1) mechanical pretreatment by itself is insufficient to attain economically feasible biomass conversion, and, therefore, (2) necessary particle sizing needs to be determined in the context of thermochemical pretreatment employed for lignocellulose conversion. Studies of thermochemical pretreatments that have taken into account particle size as a factor have exhibited a wide range of maximal sizes (i.e., particle sizes below which no increase in pretreatment effectiveness, measured in terms of the enzymatic conversion resulting from the pretreatment, were observed) from <0.15 to 50 mm. Maximal sizes as defined above were dependent on the pretreatment employed, with maximal size range decreasing as follows: steam explosion > liquid hot water > dilute acid and base pretreatments. Maximal sizes also appeared dependent on feedstock, with herbaceous or grassy biomass exhibiting lower maximal size range (<3 mm) than woody biomass (>3 mm). Such trends, considered alongside the intensive energy requirement of size reduction processes, warrant a more systematic study of particle size effects across different pretreatment technologies and feedstock, as a requisite for optimizing the feedstock supply system.
Deconstructing the power resistance relationship for squats: A joint-level analysis.
Farris, D J; Lichtwark, G A; Brown, N A T; Cresswell, A G
2016-07-01
Generating high leg power outputs is important for executing rapid movements. Squats are commonly used to increase leg strength and power. Therefore, it is useful to understand factors affecting power output in squatting. We aimed to deconstruct the mechanisms behind why power is maximized at certain resistances in squatting. Ten male rowers (age = 20 ± 2.2 years; height = 1.82 ± 0.03 m; mass = 86 ± 11 kg) performed maximal power squats with resistances ranging from body weight to 80% of their one repetition maximum (1RM). Three-dimensional kinematics was combined with ground reaction force (GRF) data in an inverse dynamics analysis to calculate leg joint moments and powers. System center of mass (COM) velocity and power were computed from GRF data. COM power was maximized across a range of resistances from 40% to 60% 1RM. This range was identified because a trade-off in hip and knee joint powers existed across this range, with maximal knee joint power occurring at 40% 1RM and maximal hip joint power at 60% 1RM. A non-linear system force-velocity relationship was observed that dictated large reductions in COM power below 20% 1RM and above 60% 1RM. These reductions were due to constraints on the control of the movement. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Intussusception reduction: Effect of air vs. liquid enema on radiation dose.
Kaplan, Summer L; Magill, Dennise; Felice, Marc A; Edgar, J Christopher; Anupindi, Sudha A; Zhu, Xiaowei
2017-10-01
Both air and radiopaque liquid contrast are used to reduce ileocolic intussusception under fluoroscopy. Some suggest air lowers radiation dose due to shorter procedure times. However, air enema likely lowers radiation dose regardless of fluoroscopy time due to less density over the automatic exposure control cells. We test the hypothesis that air enema reduction of ileocolic intussusception results in lower radiation dose than liquid contrast enema independent of fluoroscopy time. We describe a role for automatic exposure control in this dose difference. We retrospectively evaluated air and liquid intussusception reductions performed on a single digital fluoroscopic unit during a 26-month period. We compared patient age, weight, gender, exam time of day and year, performing radiologist(s), radiographic image acquisitions, grid and magnification use, fluoroscopy time and dose area product. We compared categorical and continuous variables statistically using chi-square and Mann-Whitney U tests, respectively. The mean dose area product was 2.7-fold lower for air enema, 1.3 ± 0.9 dGy·cm 2 , than for liquid, 3.5 ± 2.5 dGy·cm 2 (P<0.005). The mean fluoroscopy time was similar between techniques. The mean dose area product/min was 2.3-fold lower for air, 0.6 ± 0.2 dGy·cm 2 /min, than for liquid, 1.4 ± 0.5 dGy·cm 2 /min (P<0.001). No group differences were identified in other measured dose parameters. Fluoroscopic intussusception reduction using air enema uses less than half the radiation dose of liquid contrast enema. Dose savings are independent of fluoroscopy time and are likely due to automatic exposure control interaction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brady, S. L.; Yee, B. S.; Kaufman, R. A.
Purpose: This study demonstrates a means of implementing an adaptive statistical iterative reconstruction (ASiR Trade-Mark-Sign ) technique for dose reduction in computed tomography (CT) while maintaining similar noise levels in the reconstructed image. The effects of image quality and noise texture were assessed at all implementation levels of ASiR Trade-Mark-Sign . Empirically derived dose reduction limits were established for ASiR Trade-Mark-Sign for imaging of the trunk for a pediatric oncology population ranging from 1 yr old through adolescence/adulthood. Methods: Image quality was assessed using metrics established by the American College of Radiology (ACR) CT accreditation program. Each image quality metricmore » was tested using the ACR CT phantom with 0%-100% ASiR Trade-Mark-Sign blended with filtered back projection (FBP) reconstructed images. Additionally, the noise power spectrum (NPS) was calculated for three common reconstruction filters of the trunk. The empirically derived limitations on ASiR Trade-Mark-Sign implementation for dose reduction were assessed using (1, 5, 10) yr old and adolescent/adult anthropomorphic phantoms. To assess dose reduction limits, the phantoms were scanned in increments of increased noise index (decrementing mA using automatic tube current modulation) balanced with ASiR Trade-Mark-Sign reconstruction to maintain noise equivalence of the 0% ASiR Trade-Mark-Sign image. Results: The ASiR Trade-Mark-Sign algorithm did not produce any unfavorable effects on image quality as assessed by ACR criteria. Conversely, low-contrast resolution was found to improve due to the reduction of noise in the reconstructed images. NPS calculations demonstrated that images with lower frequency noise had lower noise variance and coarser graininess at progressively higher percentages of ASiR Trade-Mark-Sign reconstruction; and in spite of the similar magnitudes of noise, the image reconstructed with 50% or more ASiR Trade-Mark-Sign presented a more smoothed appearance than the pre-ASiR Trade-Mark-Sign 100% FBP image. Finally, relative to non-ASiR Trade-Mark-Sign images with 100% of standard dose across the pediatric phantom age spectrum, similar noise levels were obtained in the images at a dose reduction of 48% with 40% ASIR Trade-Mark-Sign and a dose reduction of 82% with 100% ASIR Trade-Mark-Sign . Conclusions: The authors' work was conducted to identify the dose reduction limits of ASiR Trade-Mark-Sign for a pediatric oncology population using automatic tube current modulation. Improvements in noise levels from ASiR Trade-Mark-Sign reconstruction were adapted to provide lower radiation exposure (i.e., lower mA) instead of improved image quality. We have demonstrated for the image quality standards required at our institution, a maximum dose reduction of 82% can be achieved using 100% ASiR Trade-Mark-Sign ; however, to negate changes in the appearance of reconstructed images using ASiR Trade-Mark-Sign with a medium to low frequency noise preserving reconstruction filter (i.e., standard), 40% ASiR Trade-Mark-Sign was implemented in our clinic for 42%-48% dose reduction at all pediatric ages without a visually perceptible change in image quality or image noise.« less
Caron, Alexis; Lelong, Christine; Bartels, T; Dorchies, O; Gury, T; Chalier, Catherine; Benning, Véronique
2015-08-01
As a general practice in rodent toxicology studies, satellite animals are used for toxicokinetic determinations, because of the potential impact of serial blood sampling on toxicological endpoints. Besides toxicological and toxicokinetic determinations, blood samples obtained longitudinally from a same animal may be used for the assessment of additional parameters (e.g., metabolism, pharmacodynamics, safety biomarkers) to maximize information that can be deduced from rodents. We investigated whether removal of up to 6 × 200 μL of blood over 24h can be applied in GLP rat toxicology studies without affecting the scientific outcome. 8 week-old female rats (200-300 g) were dosed for up to 1 month with a standard vehicle and subjected or not (controls) to serial blood sampling for sham toxicokinetic/ancillary determinations, using miniaturized methods allowing collection of 6 × 50, 100 or 200 μL over 24h. In-life endpoints, clinical pathology parameters and histopathology of organs sensitive to blood volume reduction were evaluated at several time points after completion of sampling. In sampled rats, minimal and reversible changes in red blood cell mass (maximally 15%) and subtle variations in liver enzymes, fibrinogen and neutrophils were not associated with any organ/tissue macroscopic or microscopic correlate. Serial blood sampling (up to 6 × 200 μL over 24h) is compatible with the assessment of standard toxicity endpoints in adult rats. Copyright © 2015 Elsevier Inc. All rights reserved.
Bender, B; Schabel, C; Fenchel, M; Ernemann, U; Korn, A
2015-01-01
Objective: With further increase of CT numbers and their dominant contribution to medical exposure, there is a recent quest for more effective dose control. While reintroduction of iterative reconstruction (IR) has proved its potential in many applications, a novel focus is placed on more noise efficient detectors. Our purpose was to assess the potential of IR in combination with an integrated circuit detector (ICD) for aggressive dose reduction in head CT. Methods: Non-contrast low-dose head CT [190 mAs; weighted volume CT dose index (CTDIvol), 33.2 mGy] was performed in 50 consecutive patients, using a new noise efficient detector and IR. Images were assessed in terms of quantitative and qualitative image quality and compared with standard dose acquisitions (320 mAs; CTDIvol, 59.7 mGy) using a conventional detector and filtered back projection. Results: By combining ICD and IR in low-dose examinations, the signal to noise was improved by about 13% above the baseline level in the standard-dose control group. Both, contrast-to-noise ratio (2.02 ± 0.6 vs 1.88 ± 0.4; p = 0.18) and objective measurements of image sharpness (695 ± 84 vs 705 ± 151 change in Hounsfield units per pixel; p = 0.79) were fully preserved in the low-dose group. Likewise, there was no significant difference in the grading of several subjective image quality parameters when both noise-reducing strategies were used in low-dose examinations. Conclusion: Combination of noise efficient detector with IR allows for meaningful dose reduction in head CT without compromise of standard image quality. Advances in knowledge: Our study demonstrates the feasibility of almost 50% dose reduction in head CT dose (1.1 mSv per scan) through combination of novel dose-reducing strategies. PMID:25827204
Shao, Kan; Small, Mitchell J
2011-10-01
A methodology is presented for assessing the information value of an additional dosage experiment in existing bioassay studies. The analysis demonstrates the potential reduction in the uncertainty of toxicity metrics derived from expanded studies, providing insights for future studies. Bayesian methods are used to fit alternative dose-response models using Markov chain Monte Carlo (MCMC) simulation for parameter estimation and Bayesian model averaging (BMA) is used to compare and combine the alternative models. BMA predictions for benchmark dose (BMD) are developed, with uncertainty in these predictions used to derive the lower bound BMDL. The MCMC and BMA results provide a basis for a subsequent Monte Carlo analysis that backcasts the dosage where an additional test group would have been most beneficial in reducing the uncertainty in the BMD prediction, along with the magnitude of the expected uncertainty reduction. Uncertainty reductions are measured in terms of reduced interval widths of predicted BMD values and increases in BMDL values that occur as a result of this reduced uncertainty. The methodology is illustrated using two existing data sets for TCDD carcinogenicity, fitted with two alternative dose-response models (logistic and quantal-linear). The example shows that an additional dose at a relatively high value would have been most effective for reducing the uncertainty in BMA BMD estimates, with predicted reductions in the widths of uncertainty intervals of approximately 30%, and expected increases in BMDL values of 5-10%. The results demonstrate that dose selection for studies that subsequently inform dose-response models can benefit from consideration of how these models will be fit, combined, and interpreted. © 2011 Society for Risk Analysis.
Lenders, Malte; Canaan-Kühl, Sima; Krämer, Johannes; Duning, Thomas; Reiermann, Stefanie; Sommer, Claudia; Stypmann, Jörg; Blaschke, Daniela; Üçeyler, Nurcan; Hense, Hans-Werner; Brand, Stefan-Martin; Wanner, Christoph; Weidemann, Frank; Brand, Eva
2016-03-01
Because of the shortage of agalsidase-β supply between 2009 and 2012, patients with Fabry disease either were treated with reduced doses or were switched to agalsidase-α. In this observational study, we assessed end organ damage and clinical symptoms with special focus on renal outcome after 2 years of dose-reduction and/or switch to agalsidase-α. A total of 89 adult patients with Fabry disease who had received agalsidase-β (1.0 mg/kg body wt) for >1 year were nonrandomly assigned to continue this treatment regimen (regular-dose group, n=24), to receive a reduced dose of 0.3-0.5 mg/kg and a subsequent switch to 0.2 mg/kg agalsidase-α (dose-reduction-switch group, n=28), or to directly switch to 0.2 mg/kg agalsidase-α (switch group, n=37) and were followed-up for 2 years. We assessed clinical events (death, myocardial infarction, severe arrhythmia, stroke, progression to ESRD), changes in cardiac and renal function, Fabry-related symptoms (pain, hypohidrosis, diarrhea), and disease severity scores. Determination of renal function by creatinine and cystatin C-based eGFR revealed decreasing eGFRs in the dose-reduction-switch group and the switch group. The Mainz Severity Score Index increased significantly in these two groups (P=0.02 and P<0.001, respectively), and higher frequencies of gastrointestinal pain occurred during follow-up. In conclusion, after 2 years of observation, all groups showed a stable clinical disease course with respect to serious clinical events. However, patients under agalsidase-β dose-reduction and switch or a direct switch to agalsidase-α showed a decline of renal function independent of the eGFR formula used. Copyright © 2016 by the American Society of Nephrology.
Lenders, Malte; Canaan-Kühl, Sima; Krämer, Johannes; Duning, Thomas; Reiermann, Stefanie; Sommer, Claudia; Stypmann, Jörg; Blaschke, Daniela; Üçeyler, Nurcan; Hense, Hans-Werner; Brand, Stefan-Martin; Wanner, Christoph; Weidemann, Frank
2016-01-01
Because of the shortage of agalsidase-β supply between 2009 and 2012, patients with Fabry disease either were treated with reduced doses or were switched to agalsidase-α. In this observational study, we assessed end organ damage and clinical symptoms with special focus on renal outcome after 2 years of dose-reduction and/or switch to agalsidase-α. A total of 89 adult patients with Fabry disease who had received agalsidase-β (1.0 mg/kg body wt) for >1 year were nonrandomly assigned to continue this treatment regimen (regular-dose group, n=24), to receive a reduced dose of 0.3–0.5 mg/kg and a subsequent switch to 0.2 mg/kg agalsidase-α (dose-reduction-switch group, n=28), or to directly switch to 0.2 mg/kg agalsidase-α (switch group, n=37) and were followed-up for 2 years. We assessed clinical events (death, myocardial infarction, severe arrhythmia, stroke, progression to ESRD), changes in cardiac and renal function, Fabry-related symptoms (pain, hypohidrosis, diarrhea), and disease severity scores. Determination of renal function by creatinine and cystatin C–based eGFR revealed decreasing eGFRs in the dose-reduction-switch group and the switch group. The Mainz Severity Score Index increased significantly in these two groups (P=0.02 and P<0.001, respectively), and higher frequencies of gastrointestinal pain occurred during follow-up. In conclusion, after 2 years of observation, all groups showed a stable clinical disease course with respect to serious clinical events. However, patients under agalsidase-β dose-reduction and switch or a direct switch to agalsidase-α showed a decline of renal function independent of the eGFR formula used. PMID:26185201
Hansmann, Jan; Henzler, Thomas; Gaba, Ron C; Morelli, John N
2017-01-01
We aimed to quantify and compare awareness regarding radiation dose reduction within the interventional radiology and diagnostic radiology communities. Abstracts accepted to the annual meetings of the Society of Interventional Radiology (SIR), the Cardiovascular and Interventional Radiological Society of Europe (CIRSE), the Radiological Society of North America (RSNA), and the European Congress of Radiology (ECR) between 2005 and 2015 were analyzed using the search terms "interventional/computed tomography" and "radiation dose/radiation dose reduction." A PubMed query using the above-mentioned search terms for the years of 2005-2015 was performed. Between 2005 and 2015, a total of 14 520 abstracts (mean, 660±297 abstracts) and 80 614 abstracts (mean, 3664±1025 abstracts) were presented at interventional and diagnostic radiology meetings, respectively. Significantly fewer abstracts related to radiation dose were presented at the interventional radiology meetings compared with the diagnostic radiology meetings (162 abstracts [1% of total] vs. 2706 [3% of total]; P < 0.001). On average 15±7 interventional radiology abstracts (range, 6-27) and 246±105 diagnostic radiology abstracts (range, 112-389) pertaining to radiation dose were presented at each meeting. The PubMed query revealed an average of 124±39 publications (range, 79-187) and 1205±307 publications (range, 829-1672) related to interventional and diagnostic radiology dose reduction per year, respectively (P < 0.001). The observed increase in the number of abstracts regarding radiation dose reduction in the interventional radiology community over the past 10 years has not mirrored the increased volume seen within diagnostic radiology, suggesting that increased education and discussion about this topic may be warranted.
Hansmann, Jan; Henzler, Thomas; Gaba, Ron C.; Morelli, John N.
2017-01-01
PURPOSE We aimed to quantify and compare awareness regarding radiation dose reduction within the interventional radiology and diagnostic radiology communities. METHODS Abstracts accepted to the annual meetings of the Society of Interventional Radiology (SIR), the Cardiovascular and Interventional Radiological Society of Europe (CIRSE), the Radiological Society of North America (RSNA), and the European Congress of Radiology (ECR) between 2005 and 2015 were analyzed using the search terms “interventional/computed tomography” and “radiation dose/radiation dose reduction.” A PubMed query using the above-mentioned search terms for the years of 2005–2015 was performed. RESULTS Between 2005 and 2015, a total of 14 520 abstracts (mean, 660±297 abstracts) and 80 614 abstracts (mean, 3664±1025 abstracts) were presented at interventional and diagnostic radiology meetings, respectively. Significantly fewer abstracts related to radiation dose were presented at the interventional radiology meetings compared with the diagnostic radiology meetings (162 abstracts [1% of total] vs. 2706 [3% of total]; P < 0.001). On average 15±7 interventional radiology abstracts (range, 6–27) and 246±105 diagnostic radiology abstracts (range, 112–389) pertaining to radiation dose were presented at each meeting. The PubMed query revealed an average of 124±39 publications (range, 79–187) and 1205±307 publications (range, 829–1672) related to interventional and diagnostic radiology dose reduction per year, respectively (P < 0.001). CONCLUSION The observed increase in the number of abstracts regarding radiation dose reduction in the interventional radiology community over the past 10 years has not mirrored the increased volume seen within diagnostic radiology, suggesting that increased education and discussion about this topic may be warranted. PMID:28287072
Lebovitz, Daniel J; Smith, Paul G; O'Riordan, MaryAnn; Reed, Michael D
2004-01-01
Background: Asthmatic children requiring treatment in the pediatric intensive care unit (PICU) receive aggressive drug therapy that may include IV administration of β2-receptor agonists to prevent progression to life-threatening respiratory failure. The only pharmacologic agent in this class currently available for parenteral use in the United States is terbutaline. Study of IV dosing of terbutaline in the pediatric population has been limited. Objective: The aim of this study was to determine the pharmacokinetic (PK) properties and tolerability of single-dose terbutaline in pediatric patients across a broad age range who were admitted to the PICU and were receiving maximal conventional asthma drug therapy. Methods: This study was conducted at the PICU at Rainbow Babies and Children's Hospital (Cleveland, Ohio). Patients aged 6 months to 16 years with severe exacerbation of reactive airways disease and who were undergoing maximal conventional therapy and had an arterial catheter were enrolled. Patients were arbitrarily assigned to receive a single IV infusion of 1 of 3 doses of terbutaline (10, 20, or 30 μg/kg), infused over 5 minutes. Blood samples were obtained for the determination of plasma terbutaline concentrations just before terbutaline was administered (baseline), immediately on completion of the IV infusion, and at 10, 20, and 40 minutes and 1, 2, 4, 8, 16, 32, 48, and 72 hours after the 5-minute infusion. PK properties (elimination half-life [tl2], mean residence time [MRT], apparent steady-state volume of distribution [Vdss], and total body clearance [CI]) were determined and adverse effects were recorded. Results: The determination of terbutaline PK properties was possible in 50 of 56 enrolled patients (31 boys, 19 girls; mean [SD] age, 6.5 [4.5] years). The PK properties of terbutaline were linear over the dose range studied and, with the exception of the expected dose-dependent increases in peak terbutaline plasma concentration and area under the terbutaline plasma concentration-time curve, no statistically significant differences were observed in PK relative to dose. Therefore, we pooled the data for all subsequent analyses. Statistically significant correlations with patient age were observed with tl2 (r = 0.4, P < 0.006), MRT (r = 0.4, P < 0.002), and Vdss (r = 0.33, P < 0.02), but not C1 (r = −0.03, P = NS). Single-dose terbutaline administration was generally well tolerated. Conclusions: Single-dose IV terbutaline was well tolerated in this study. In maximally treated asthmatic patients in the PICU, terbutaline elimination may be more rapid than in nonacutely ill children. These PK data suggest that if the drug is to be administered intravenously, the continuous IV infusion method, including loading doses for any subsequent dose escalations, may be the most appropriate. The influence of age and safety of long-term, continuous terbutaline IV infusion requires further study. PMID:24936108
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mukherjee, S; Farr, J; Merchant, T
Purpose: To study the effect of total-variation based noise reduction algorithms to improve the image registration of low-dose CBCT for patient positioning in radiation therapy. Methods: In low-dose CBCT, the reconstructed image is degraded by excessive quantum noise. In this study, we developed a total-variation based noise reduction algorithm and studied the effect of the algorithm on noise reduction and image registration accuracy. To study the effect of noise reduction, we have calculated the peak signal-to-noise ratio (PSNR). To study the improvement of image registration, we performed image registration between volumetric CT and MV- CBCT images of different head-and-neck patientsmore » and calculated the mutual information (MI) and Pearson correlation coefficient (PCC) as a similarity metric. The PSNR, MI and PCC were calculated for both the noisy and noise-reduced CBCT images. Results: The algorithms were shown to be effective in reducing the noise level and improving the MI and PCC for the low-dose CBCT images tested. For the different head-and-neck patients, a maximum improvement of PSNR of 10 dB with respect to the noisy image was calculated. The improvement of MI and PCC was 9% and 2% respectively. Conclusion: Total-variation based noise reduction algorithm was studied to improve the image registration between CT and low-dose CBCT. The algorithm had shown promising results in reducing the noise from low-dose CBCT images and improving the similarity metric in terms of MI and PCC.« less
A feasibility study of dynamic adaptive radiotherapy for nonsmall cell lung cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Minsun, E-mail: mk688@uw.edu; Phillips, Mark H.
2016-05-15
Purpose: The final state of the tumor at the end of a radiotherapy course is dependent on the doses given in each fraction during the treatment course. This study investigates the feasibility of using dynamic adaptive radiotherapy (DART) in treating lung cancers assuming CBCT is available to observe midtreatment tumor states. DART adapts treatment plans using a dynamic programming technique to consider the expected changes of the tumor in the optimization process. Methods: DART is constructed using a stochastic control formalism framework. It minimizes the total expected number of tumor cells at the end of a treatment course, which ismore » equivalent to maximizing tumor control probability, subject to the uncertainty inherent in the tumor response. This formulation allows for nonstationary dose distributions as well as nonstationary fractional doses as needed to achieve a series of optimal plans that are conformal to the tumor over time, i.e., spatiotemporally optimal plans. Sixteen phantom cases with various sizes and locations of tumors and organs-at-risk (OAR) were generated using in-house software. Each case was planned with DART and conventional IMRT prescribing 60 Gy in 30 fractions. The observations of the change in the tumor volume over a treatment course were simulated using a two-level cell population model. Monte Carlo simulations of the treatment course for each case were run to account for uncertainty in the tumor response. The same OAR dose constraints were applied for both methods. The frequency of replanning was varied between 1, 2, 5 (weekly), and 29 times (daily). The final average tumor dose and OAR doses have been compared to quantify the potential dosimetric benefits of DART. Results: The average tumor max, min, mean, and D95 doses using DART relative to these using conventional IMRT were 124.0%–125.2%, 102.1%–114.7%, 113.7%–123.4%, and 102.0%–115.9% (range dependent on the frequency of replanning). The average relative maximum doses for the cord and esophagus, mean doses for the heart and lungs, and D05 for the unspecified tissue resulting 84%–102.4%, 99.8%–106.9%, 66.9%–85.6%, 58.2%–78.8%, and 85.2%–94.0%, respectively. Conclusions: It is feasible to apply DART to the treatment of NSCLC using CBCT to observe the midtreatment tumor state. Potential increases in the tumor dose and reductions in the OAR dose, particularly for parallel OARs with mean or dose–volume constraints, could be achieved using DART compared to nonadaptive IMRT.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ron Warren
2006-12-01
An assessment of the potential radiation dose that residents offsite of the Nevada Test Site (NTS) might receive from the proposed Divine Strake experiment was made to determine compliance with Subpart H of Part 61 of Title 40 of the Code of Federal Regulations, National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities. The Divine Strake experiment, proposed by the Defense Threat Reduction Agency, consists of a detonation of 700 tons of heavy ammonium nitrate fuel oil-emulsion above the U16b Tunnel complex in Area 16 of the NTS. Both natural radionuclides suspended, and historicmore » fallout radionuclides resuspended from the detonation, have potential to be transported outside the NTS boundary by wind. They may, therefore, contribute radiological dose to the public. Subpart H states ''Emissions of radionuclides to the ambient air from Department of Energy facilities shall not exceed those amounts that would cause any member of the public to receive in any year an effective dose equivalent of 10 mrem/yr'' (Title 40 of the Code of Federal Regulations [CFR] 61.92) where mrem/yr is millirem per year. Furthermore, application for U.S. Environmental Protection Agency (EPA) approval of construction of a new source or modification of an existing source is required if the effective dose equivalent, caused by all emissions from the new construction or modification, is greater than or equal to 0.1 mrem/yr (40 CFR 61.96). In accordance with Section 61.93, a dose assessment was conducted with the computer model CAP88-PC, Version 3.0. In addition to this model, a dose assessment was also conducted by the National Atmospheric Release Advisory Center (NARAC) at the Lawrence Livermore National Laboratory. This modeling was conducted to obtain dose estimates from a model designed for acute releases and which addresses terrain effects and uses meteorology from multiple locations. Potential radiation dose to a hypothetical maximally exposed individual at the closest NTS boundary to the proposed Divine Strake experiment, as estimated by the CAP88-PC model, was 0.005 mrem with wind blowing directly towards that location. Boundary dose, as modeled by NARAC, ranged from about 0.006 to 0.007 mrem. Potential doses to actual offsite populated locations were generally two to five times lower still, or about 40 to 100 times lower then the 0.1 mrem level at which EPA approval is required pursuant to Section 61.96.« less
Radenkovic, Filip; Holland, Olivia; Vanderlelie, Jessica J; Perkins, Anthony V
2017-12-15
Auranofin is a thiol-reactive gold (I)-containing compound with potential asa chemotherapeutic. Auranofin has the capacity to selectively inhibit endogenous antioxidant enzymes thioredoxin reductase (TrxR) and glutathione peroxidase (GPx), resulting in oxidative stress and the initiation of a pro-apoptotic cascade. The effect of Auranofin exposure on TrxR and GPx, and the potential for cellular protection through selenium supplementation was examined in the non-cancerous human cell line Swan-71. Auranofin exposure resulted in a concentration dependent differential inhibition of selenoprotein antioxidants. Significant inhibition of TrxR was observed at 20nM Auranofin with inhibition of GPx from 10µM. Significant increases in reactive oxygen species (ROS) were associated with antioxidant inhibition at Auranofin concentrations of 100nM (TrxR inhibition) and 10µM (TrxR and GPx inhibition), respectively. Evaluation of mitochondrial respiration demonstrated significant reductions in routine and maximal respiration at both 100nM and 10μM Auranofin. Auranofin treatment at concentrations of 10μM and higher concentrations resulted in a ∼68% decrease in cellular viability and was associated with elevations in pro-apoptotic markers cytochrome c flux control factor (FCFc) at concentration of 100nM and mitochondrial Bax at 10μM. The supplementation of selenium (100nM) prior to treatment had a generalized protective affect through the restoration of antioxidant activity with a significant increase in TrxR and GPx activity, a significant reduction in ROS and associated improvement in mitochondrial respiration and cellular viability (10µM ∼48% increase). Selenium supplementation reduced the FCFc at low doses of Auranofin (<10μM) however no effect was noted on either FCFc or Bax at concentrations above 10μM. The inhibition of antioxidant systems in non-cancerous cells by Auranofin is strongly dose dependent, and this inhibition can be altered by selenium exposure. Therefore, Auranofin dose and the selenium status of patients are important considerations in the therapeutic use of Auranofin as an agent of chemosensitization. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
Risk Factors for Symptomatic Avascular Necrosis in Childhood-onset Systemic Lupus Erythematosus.
Yang, Yelin; Kumar, Sathish; Lim, Lily Siok Hoon; Silverman, Earl D; Levy, Deborah M
2015-12-01
To examine the frequency and risk factors for symptomatic avascular necrosis (AVN) in childhood-onset systemic lupus erythematosus (cSLE). A single-center, nested, matched, case-control design was used. There were 617 patients with cSLE followed at the Hospital for Sick Children (SickKids) Lupus Clinic between July 1982 and June 2013 included in the study. The AVN cohort consisted of 37 patients identified with clinical findings of symptomatic AVN and diagnosis was confirmed by 1 or more imaging modalities. Three controls were matched to each patient with AVN by date and age at diagnosis. Baseline clinical, laboratory, and treatment characteristics were compared between patients with AVN and controls by univariable analyses and if statistically significant, were included in a multivariable logistic regression model. A total of 37/617 patients (6%) developed symptomatic AVN in 91 joints during followup at SickKids. The mean duration to disease was 2.3 years. The hip was the most commonly involved joint (26/37, 70%). Compared with the matched non-AVN cohort, patients with AVN had a higher incidence of central nervous system (CNS) involvement and nephritis, required greater cumulative prednisone (PRED) from cSLE diagnosis to AVN, received a greater maximal daily PRED dose, and had more frequent use of pulse methylprednisolone therapy. Multivariable regression analysis confirmed major organ involvement (CNS disease and/or nephritis) and maximal daily PRED dose as significant predictors of symptomatic AVN development. Patients with cSLE with severe organ involvement including nephritis and CNS disease and higher maximal daily dose of PRED are more likely to develop symptomatic AVN.
Paediatric x-ray radiation dose reduction and image quality analysis.
Martin, L; Ruddlesden, R; Makepeace, C; Robinson, L; Mistry, T; Starritt, H
2013-09-01
Collaboration of multiple staff groups has resulted in significant reduction in the risk of radiation-induced cancer from radiographic x-ray exposure during childhood. In this study at an acute NHS hospital trust, a preliminary audit identified initial exposure factors. These were compared with European and UK guidance, leading to the introduction of new factors that were in compliance with European guidance on x-ray tube potentials. Image quality was assessed using standard anatomical criteria scoring, and visual grading characteristics analysis assessed the impact on image quality of changes in exposure factors. This analysis determined the acceptability of gradual radiation dose reduction below the European and UK guidance levels. Chest and pelvis exposures were optimised, achieving dose reduction for each age group, with 7%-55% decrease in critical organ dose. Clinicians confirmed diagnostic image quality throughout the iterative process. Analysis of images acquired with preliminary and final exposure factors indicated an average visual grading analysis result of 0.5, demonstrating equivalent image quality. The optimisation process and final radiation doses are reported for Carestream computed radiography to aid other hospitals in minimising radiation risks to children.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Papadakis, Antonios E.; Perisinakis, Kostas; Damilakis, John
2007-07-15
The purpose of this study was to assess the potential of angular on-line tube current modulation on dose reduction in pediatric and adult patients undergoing multidetector computed tomography (MDCT) examinations. Five physical anthropomorphic phantoms that simulate the average individual as neonate, 1-year-old, 5-year-old, 10-year-old, and adult were employed in the current study. Phantoms were scanned with the use of on-line tube current modulation (TCM). Percent dose reduction (%DR) factors achieved by applying TCM, were determined for standard protocols used for head and neck, shoulder, thorax, thorax and abdomen, abdomen, abdomen and pelvis, pelvis, and whole body examinations. A preliminary studymore » on the application of TCM in MDCT examinations of adult patients was performed to validate the results obtained in anthropomorphic phantoms. Dose reduction was estimated as the percentage difference of the modulated milliamperes for each scan and the preset milliamperes prescribed by the scan protocol. The dose reduction in children was found to be much lower than the corresponding reduction achieved for adults. For helical scans the %DR factors, ranged between 1.6% and 7.4% for the neonate, 2.9% and 8.7% for the 1-year old, 2% and 6% for the 5-year-old, 5% and 10.9% for the 10-year-old, and 10.4% and 20.7% for the adult individual. For sequential scans the corresponding %DR factors ranged between 1.3% and 6.7%, 4.5% and 11%, 4.2% and 6.6%, 6.4% and 12.3%, and 8.9% and 23.3%, respectively. Broader beam collimations are associated with decreased %DR factors, when other scanning parameters are held constant. TCM did not impair image noise. In adult patients, the %DR values were found to be in good agreement with the corresponding results obtained in the anthropomorphic adult phantom. In conclusion, on-line TCM may be considered as a valuable tool for reducing dose in routine CT examinations of pediatric and adult patients. However, the dose reduction achieved with TCM in neonates and young children was found to be lower than that obtained for adults. Therefore, on-line TCM should work as an additional means to reduce dose and should not replace other conventional means of reducing dose, especially in neonates and young children.« less
A Highly Durable RNAi Therapeutic Inhibitor of PCSK9
Fitzgerald, Kevin; White, Suellen; Borodovsky, Anna; Bettencourt, Brian R.; Strahs, Andrew; Clausen, Valerie; Wijngaard, Peter; Horton, Jay D.; Taubel, Jorg; Brooks, Ashley; Fernando, Chamikara; Kauffman, Robert S.; Kallend, David; Vaishnaw, Akshay; Simon, Amy
2018-01-01
BACKGROUND Inclisiran (ALN-PCSsc) is a long-acting RNA interference (RNAi) therapeutic agent that inhibits the synthesis of proprotein convertase subtilisin–kexin type 9 (PCSK9), a target for the lowering of low-density lipoprotein (LDL) cholesterol. METHODS In this phase 1 trial, we randomly assigned healthy volunteers with an LDL cholesterol level of at least 100 mg per deciliter in a 3:1 ratio to receive a subcutaneous injection of inclisiran or placebo in either a single-ascending-dose phase (at a dose of 25, 100, 300, 500, or 800 mg) or a multiple-dose phase (125 mg weekly for four doses, 250 mg every other week for two doses, or 300 or 500 mg monthly for two doses, with or without concurrent statin therapy); each dose cohort included four to eight participants. Safety, the side-effect profile, and pharmacodynamic measures (PCSK9 level, LDL cholesterol level, and exploratory lipid variables) were evaluated. RESULTS The most common adverse events were cough, musculoskeletal pain, nasopharyngitis, headache, back pain, and diarrhea. All the adverse events were mild or moderate in severity. There were no serious adverse events or discontinuations due to adverse events. There was one grade 3 elevation in the γ-glutamyltransferase level, which was considered by the investigator to be related to statin therapy. In the single-dose phase, inclisiran doses of 300 mg or more reduced the PCSK9 level (up to a least-squares mean reduction of 74.5% from baseline to day 84), and doses of 100 mg or more reduced the LDL cholesterol level (up to a least-squares mean reduction of 50.6% from baseline). Reductions in the levels of PCSK9 and LDL cholesterol were maintained at day 180 for doses of 300 mg or more. All multiple-dose regimens reduced the levels of PCSK9 (up to a least-squares mean reduction of 83.8% from baseline to day 84) and LDL cholesterol (up to a least-squares mean reduction of 59.7% from baseline to day 84). CONCLUSIONS In this phase 1 trial, no serious adverse events were observed with inclisiran. Doses of 300 mg or more (in single or multiple doses) significantly reduced levels of PCSK9 and LDL cholesterol for at least 6 months. (Funded by Alnylam Pharmaceuticals and the Medicines Company; ClinicalTrials.gov number, NCT02314442.) PMID:27959715
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Jia; Duan Xinhui; Christner, Jodie A.
2011-11-15
Purpose: The purpose of this work was to evaluate dose performance and image quality in thoracic CT using three techniques to reduce dose to the breast: bismuth shielding, organ-based tube current modulation (TCM) and global tube current reduction. Methods: Semi-anthropomorphic thorax phantoms of four different sizes (15, 30, 35, and 40 cm lateral width) were used for dose measurement and image quality assessment. Four scans were performed on each phantom using 100 or 120 kV with a clinical CT scanner: (1) reference scan; (2) scan with bismuth breast shield of an appropriate thickness; (3) scan with organ-based TCM; and (4)more » scan with a global reduction in tube current chosen to match the dose reduction from bismuth shielding. Dose to the breast was measured with an ion chamber on the surface of the phantom. Image quality was evaluated by measuring the mean and standard deviation of CT numbers within the lung and heart regions. Results: Compared to the reference scan, dose to the breast region was decreased by about 21% for the 15-cm phantom with a pediatric (2-ply) shield and by about 37% for the 30, 35, and 40-cm phantoms with adult (4-ply) shields. Organ-based TCM decreased the dose by 12% for the 15-cm phantom, and 34-39% for the 30, 35, and 40-cm phantoms. Global lowering of the tube current reduced breast dose by 23% for the 15-cm phantom and 39% for the 30, 35, and 40-cm phantoms. In phantoms of all four sizes, image noise was increased in both the lung and heart regions with bismuth shielding. No significant increase in noise was observed with organ-based TCM. Decreasing tube current globally led to similar noise increases as bismuth shielding. Streak and beam hardening artifacts, and a resulting artifactual increase in CT numbers, were observed for scans with bismuth shields, but not for organ-based TCM or global tube current reduction. Conclusions: Organ-based TCM produces dose reduction to the breast similar to that achieved with bismuth shielding for both pediatric and adult phantoms. However, organ-based TCM does not affect image noise or CT number accuracy, both of which are adversely affected by bismuth shielding. Alternatively, globally decreasing the tube current can produce the same dose reduction to the breast as bismuth shielding, with a similar noise increase, yet without the streak artifacts and CT number errors caused by the bismuth shields. Moreover, globally decreasing the tube current reduces the dose to all tissues scanned, not simply to the breast.« less
NASA Astrophysics Data System (ADS)
Renger, Bernhard; Rummeny, Ernst J.; Noël, Peter B.
2013-03-01
During the last decades, the reduction of radiation exposure especially in diagnostic computed tomography is one of the most explored topics. In the same time, it seems challenging to quantify the long-term clinical dose reduction with regard to new hardware as well as software solutions. To overcome this challenge, we developed a Dose Monitoring System (DMS), which collects information from PACS, RIS, MPPS and structured reports. The integration of all sources overcomes the weaknesses of single systems. To gather all possible information, we integrated an optical character recognition system to extract, for example, information from the CT-dose-report. All collected data are transferred to a database for further evaluation, e.g., for calculations of effective as well as organ doses. The DMS provides a single database for tracking all essential study and patient specific information across different modality as well as different vendors. As an initial study, we longitudinally investigated the dose reduction in CT examination when employing a noise-suppressing reconstruction algorithm. For this examination type a significant long-term reduction in radiation exposure is reported, when comparing to a CT-system with standard reconstruction. In summary our DMS tool not only enables us to track radiation exposure on daily bases but further enables to analyses the long term effect of new dose saving strategies. In the future the statistical analyses of all retrospective data, which are available in a modern imaging department, will provide a unique overview of advances in reduction of radiation exposure.
Efficacy of apolipoprotein B synthesis inhibition in subjects with mild-to-moderate hyperlipidaemia.
Akdim, Fatima; Tribble, Diane L; Flaim, JoAnn D; Yu, Rosie; Su, John; Geary, Richard S; Baker, Brenda F; Fuhr, Rainard; Wedel, Mark K; Kastelein, John J P
2011-11-01
Mipomersen, an apolipoprotein (apo) B synthesis inhibitor, has been shown to produce potent reductions in apoB and LDL-cholesterol levels in animal models as well as healthy human volunteers. A randomized, double-blind, placebo-controlled, dose-escalation study was designed to evaluate the efficacy and safety of mipomersen monotherapy with or without dose loading in subjects with mild-to-moderate hyperlipidaemia. Fifty subjects with LDL-cholesterol levels between 119 and 266 mg/dL were enrolled into five cohorts at a 4:1 randomization ratio of active to placebo. Two 13-week dose regimens were evaluated at doses ranging from 50 to 400 mg/week. Mipomersen produced dose-dependent reductions in all apoB containing lipoproteins. In the 200 and 300 mg/week dose cohorts, mean reductions from baseline in LDL cholesterol were -45 ± 10% (P= 0.000) and -61 ± 8% (P= 0.000), corresponding to a -46 ± 11% (P= 0.000) and -61 ± 7% (P= 0.000) decrease in apoB levels. Triglyceride levels were also lowered with median reductions up to 53% (P= 0.021). The most common adverse events were injection site reactions. Seven of 40 subjects (18%) showed consecutive transaminase elevations >3× upper limit of normal. Five of these subjects received 400 mg/week, four of whom had apoB levels below the limit of detection. As a consequence, the 400 mg/week cohort was discontinued. Mipomersen administered as monotherapy in subjects with mild-to-moderate hyperlipidaemia produced potent reductions in all apoB-containing lipoproteins. Higher doses were associated with hepatic transaminase increases.
Technical Note: On maximizing Cherenkov emissions from medical linear accelerators.
Shrock, Zachary; Yoon, Suk W; Gunasingha, Rathnayaka; Oldham, Mark; Adamson, Justus
2018-04-19
Cherenkov light during MV radiotherapy has recently found imaging and therapeutic applications but is challenged by relatively low fluence. Our purpose is to investigate the feasibility of increasing Cherenkov light production during MV radiotherapy by increasing photon energy and applying specialized beam-hardening filtration. GAMOS 5.0.0, a GEANT4-based framework for Monte Carlo simulations, was used to model standard clinical linear accelerator primary photon beams. The photon source was incident upon a 17.8 cm 3 cubic water phantom with a 94 cm source to surface distance. Dose and Cherenkov production was determined at depths of 3-9 cm. Filtration was simulated 15 cm below the photon beam source. Filter materials included aluminum, iron, and copper with thicknesses of 2-20 cm. Histories used depended on the level of attenuation from the filter, ranging from 100 million to 2 billion. Comparing average dose per history also allowed for evaluation of dose-rate reduction for different filters. Overall, increasing photon beam energy is more effective at improving Cherenkov production per unit dose than is filtration, with a standard 18 MV beam yielding 3.3-4.0× more photons than 6 MV. Introducing an aluminum filter into an unfiltered 2400 cGy/min 10 MV beam increases the Cherenkov production by 1.6-1.7×, while maintaining a clinical dose rate of 300 cGy/min, compared to increases of ~1.5× for iron and copper. Aluminum was also more effective than the standard flattening filter, with the increase over the unfiltered beam being 1.4-1.5× (maintaining 600 cGy/min dose rate) vs 1.3-1.4× for the standard flattening filter. Applying a 10 cm aluminum filter to a standard 18 MV, photon beam increased the Cherenkov production per unit dose to 3.9-4.3× beyond that of 6 MV (vs 3.3-4.0× for 18 MV with no aluminum filter). Through a combination of increasing photon energy and applying specialized beam-hardening filtration, the amount of Cherenkov photons per unit radiotherapy dose can be increased substantially. © 2018 American Association of Physicists in Medicine.
Pawar, Mohit; Kumar, Priyank; Sunkaraneni, Soujanya; Sirohi, Sunil; Walker, Ellen A; Yoburn, Byron C
2007-06-01
It has been proposed that opioid agonist efficacy may play a role in tolerance and the regulation of opioid receptor density. To address this issue, the present studies estimated the in vivo efficacy of three opioid agonists and then examined changes in spinal mu-opioid receptor density following chronic treatment in the mouse. In addition, tolerance and regulation of the trafficking protein dynamin-2 were determined. To evaluate efficacy, the method of irreversible receptor alkylation was employed and the efficacy parameter tau estimated. Mice were injected with the irreversible mu-opioid receptor antagonist clocinnamox (0.32-25.6 mg/kg, i.p), and 24 h later, the analgesic potency of s.c. morphine, oxycodone and etorphine were determined. Clocinnamox dose-dependently antagonized the analgesic effects of morphine, etorphine and oxycodone. The shift to the right of the dose-response curves was greater for morphine and oxycodone compared to etorphine and the highest dose of clocinnamox reduced the maximal effect of morphine and oxycodone, but not etorphine. The order of efficacy calculated from these results was etorphine>morphine>oxycodone. Other mice were infused for 7 days with oxycodone (10-150 mg/kg/day, s.c.) or etorphine (50-250 microg/kg/day, s.c.) and the analgesic potency of s.c. morphine determined. The low efficacy agonist (oxycodone) produced more tolerance than the high efficacy agonist (etorphine) at equi-effective infusion doses. In saturation binding experiments, the low efficacy opioid agonists (morphine, oxycodone) did not regulate the density of spinal mu-opioid receptors, while etorphine produced approximately 40% reduction in mu-opioid receptor density. Furthermore, etorphine increased spinal dynamin-2 abundance, while oxycodone did not produce any significant change in dynamin-2 abundance. Overall, these data indicate that high efficacy agonists produce less tolerance at equi-effective doses. Furthermore, increased efficacy was associated with mu-opioid receptor downregulation and dynamin-2 upregulation. Conversely, lower efficacy agonists produced more tolerance at equi-effective doses, but did not regulate mu-opioid receptor density or dynamin-2 abundance. Taken together, these studies indicate that agonist efficacy plays an important role in tolerance and regulation of receptors and trafficking proteins.
The efficacy of intracoelomic fospropofol in red-eared sliders (Trachemys scripta elegans).
Schroeder, Carrie A; Johnson, Rebecca A
2013-12-01
Intravenous anesthetic delivery in reptiles can be challenging. Current injectable techniques have varied induction/recovery times and anesthetic quality. This study hypothesized that intracoelomic administration of a new anesthetic, fospropofol, in turtles would result in dose-dependent anesthesia and respiratory depression. A two-part prospective trial using adult red-eared slider turtles (Trachemys scripta elegans) weighing 764 +/- 17 g was conducted to determine an effective anesthetic dose and to evaluate the anesthetic quality, duration, and respiratory effects of an efficacious dose. In part 1, six turtles were randomly administered 25-mg/ kg (low-dose [LD]) and 50-mg/kg (high-dose [HD]) fospropofol in a crossover design. Respiratory rate, immobility, and muscle relaxation scores were evaluated for 180 min. In part 2, eight turtles were administered HD fospropofol. Immobility and muscle relaxation (front and hind limb) scores and time to endotracheal intubation/extubation were evaluated until scores returned to baseline. In part 1, the LD group had significantly lower immobility and muscle relaxation scores versus the HD group over time (both P < 0.05); scores were significantly elevated from baseline for 20-120 min and 15-180 min, respectively (all P < 0.05). Although not significantly different between groups (P > 0.05), respiratory rate was significantly decreased from baseline from 10 to 120 min (all P < 0.05). In part 2, HD fospropofol decreased respiratory rate from 21.5 +/- 2.9 breaths/min to 0.1 +/- 0.1 breaths/min, similar to the results in part 1. Maximal reductions in mobility and front and hind limb motor tone occurred at 39.0 +/- 4.1, 30.8 +/- 3.6, and 24.0 +/- 3.6 min, respectively. Intubation in 7/8 turtles occurred at 45.7 +/- 5.4 min and extubation at 147.0 +/- 23.2 min. However, 2/8 turtles showed prolonged anesthetic effects, requiring resuscitative efforts for recovery. Due to the unpredictable quality and duration of anesthesia with intracoelomic fospropofol, it should be used with caution for general anesthesia in red-eared sliders at the doses and administration route investigated.
THE EFFICACY OF INTRACOELOMIC FOSPROPOFOL IN RED-EARED SLIDERS (TRACHEMYS SCRIPTA)
Schroeder, Carrie A.; Johnson, Rebecca A.
2015-01-01
Intravenous anesthetic delivery in reptiles can be challenging; current injectable techniques have varied induction/recovery times and anesthetic quality. This study hypothesized that intracoelomic administration of a new anesthetic, fospropofol, in turtles would result in dose-dependent anesthesia and respiratory depression. A two-part prospective trial using adult red-eared slider turtles (Trachemys scripta) weighing 764±17 g was conducted to 1) determine an effective anesthetic dose, and 2) evaluate the anesthetic quality, duration and respiratory effects of an efficacious dose. In Part 1, six turtles were randomly administered 25 mg kg−1 (low dose: LD) and 50 mg kg−1 (high dose: HD) fospropofol in a cross-over design. Respiratory rate, immobility and muscle relaxation scores were evaluated for 180 minutes. In Part 2, eight turtles were administered HD fospropofol. Immobility and muscle relaxation (front and hind limb) scores, and time to endotracheal intubation/extubation were evaluated until scores returned to baseline. In Part 1, the LD group had significantly lower immobility and muscle relaxation scores versus the HD group over time (both P<0.05); scores were significantly elevated from baseline for 20–120 minutes and 15–180 minutes, respectively (all P<0.05). Although not significantly different between groups (P>0.05), respiratory rate was significantly decreased from baseline from 10–120 minutes (all P<0.05). In Part 2, HD fospropofol decreased respiratory rate from 21.5±2.9 breaths min−1 to 0.1±0.1 breaths min−1, similar to the results in Part 1. Maximal reductions in immobility, front and hind limb motor tone occurred at 39.0±4.1, 30.8±3.6, and 24.0±3.6 minutes, respectively. Intubation in 7/8 turtles occurred at 45.7±5.4 min and extubation at 147.0±23.2 min. However, 2/8 turtles showed prolonged anesthetic effects, requiring resuscitative efforts for recovery. Due to the unpredictable quality and duration of anesthesia with intracoelomic fospropofol, it should be used with caution for general anesthesia in red-eared sliders at the doses and administration route investigated. PMID:24450053
Effect of Varient Dosages of Amphetamine Upon Endurance
ERIC Educational Resources Information Center
Williams, Melvin H.; Thompson, John
1973-01-01
This study sought to provide basic information concerning the acute effects of a small, moderate, and large dose of d-amphetamine sulfate upon muscular endurance; a secondary purpose involved the effect upon submaximal and maximal heart rate. (Author/JA)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Power, S.; Mirza, M.; Thakorlal, A.
PurposeThis prospective pilot study was undertaken to evaluate the feasibility and effectiveness of using a radiation absorbing shield to reduce operator dose from scatter during lower limb endovascular procedures.Materials and MethodsA commercially available bismuth shield system (RADPAD) was used. Sixty consecutive patients undergoing lower limb angioplasty were included. Thirty procedures were performed without the RADPAD (control group) and thirty with the RADPAD (study group). Two separate methods were used to measure dose to a single operator. Thermoluminescent dosimeter (TLD) badges were used to measure hand, eye, and unshielded body dose. A direct dosimeter with digital readout was also used tomore » measure eye and unshielded body dose. To allow for variation between control and study groups, dose per unit time was calculated.ResultsTLD results demonstrated a significant reduction in median body dose per unit time for the study group compared with controls (p = 0.001), corresponding to a mean dose reduction rate of 65 %. Median eye and hand dose per unit time were also reduced in the study group compared with control group, however, this was not statistically significant (p = 0.081 for eye, p = 0.628 for hand). Direct dosimeter readings also showed statistically significant reduction in median unshielded body dose rate for the study group compared with controls (p = 0.037). Eye dose rate was reduced for the study group but this was not statistically significant (p = 0.142).ConclusionInitial results are encouraging. Use of the shield resulted in a statistically significant reduction in unshielded dose to the operator’s body. Measured dose to the eye and hand of operator were also reduced but did not reach statistical significance in this pilot study.« less
Morel, Baptiste; Rouffet, David M.; Saboul, Damien; Rota, Samuel; Clémençon, Michel; Hautier, Christophe A.
2015-01-01
Rapid force production is critical to improve performance and prevent injuries. However, changes in rate of force/torque development caused by the repetition of maximal contractions have received little attention. The aim of this study was to determine the relative influence of rate of torque development (RTD) and peak torque (Tpeak) on the overall performance (i.e. mean torque, Tmean) decrease during repeated maximal contractions and to investigate the contribution of contractile and neural mechanisms to the alteration of the various mechanical variables. Eleven well-trained men performed 20 sets of 6-s isokinetic maximal knee extensions at 240°·s-1, beginning every 30 seconds. RTD, Tpeak and Tmean as well as the Rate of EMG Rise (RER), peak EMG (EMGpeak) and mean EMG (EMGmean) of the vastus lateralis were monitored for each contraction. A wavelet transform was also performed on raw EMG signal for instant mean frequency (ifmean) calculation. A neuromuscular testing procedure was carried out before and immediately after the fatiguing protocol including evoked RTD (eRTD) and maximal evoked torque (eTpeak) induced by high frequency doublet (100 Hz). Tmean decrease was correlated to RTD and Tpeak decrease (R²=0.62; p<0.001; respectively β=0.62 and β=0.19). RER, eRTD and initial ifmean (0-225 ms) decreased after 20 sets (respectively -21.1±14.1, -25±13%, and ~20%). RTD decrease was correlated to RER decrease (R²=0.36; p<0.05). The eTpeak decreased significantly after 20 sets (24±5%; p<0.05) contrary to EMGpeak (-3.2±19.5 %; p=0.71). Our results show that reductions of RTD explained part of the alterations of the overall performance during repeated moderate velocity maximal exercise. The reductions of RTD were associated to an impairment of the ability of the central nervous system to maximally activate the muscle in the first milliseconds of the contraction. PMID:25901576
Cardiovascular consequences of bed rest: effect on maximal oxygen uptake
NASA Technical Reports Server (NTRS)
Convertino, V. A.
1997-01-01
Maximal oxygen uptake (VO2max) is reduced in healthy individuals confined to bed rest, suggesting it is independent of any disease state. The magnitude of reduction in VO2max is dependent on duration of bed rest and the initial level of aerobic fitness (VO2max), but it appears to be independent of age or gender. Bed rest induces an elevated maximal heart rate which, in turn, is associated with decreased cardiac vagal tone, increased sympathetic catecholamine secretion, and greater cardiac beta-receptor sensitivity. Despite the elevation in heart rate, VO2max is reduced primarily from decreased maximal stroke volume and cardiac output. An elevated ejection fraction during exercise following bed rest suggests that the lower stroke volume is not caused by ventricular dysfunction but is primarily the result of decreased venous return associated with lower circulating blood volume, reduced central venous pressure, and higher venous compliance in the lower extremities. VO2max, stroke volume, and cardiac output are further compromised by exercise in the upright posture. The contribution of hypovolemia to reduced cardiac output during exercise following bed rest is supported by the close relationship between the relative magnitude (% delta) and time course of change in blood volume and VO2max during bed rest, and also by the fact that retention of plasma volume is associated with maintenance of VO2max after bed rest. Arteriovenous oxygen difference during maximal exercise is not altered by bed rest, suggesting that peripheral mechanisms may not contribute significantly to the decreased VO2max. However reduction in baseline and maximal muscle blood flow, red blood cell volume, and capillarization in working muscles represent peripheral mechanisms that may contribute to limited oxygen delivery and, subsequently, lowered VO2max. Thus, alterations in cardiac and vascular functions induced by prolonged confinement to bed rest contribute to diminution of maximal oxygen uptake and reserve capacity to perform physical work.
NASA Astrophysics Data System (ADS)
Lee, H. B.; Ong, B. B.; Katta, M.; Yvon, C.; Lu, L.; Zakri, R.; Patel, N.
2018-03-01
Subretinal hyper-reflective material (SHRM) seen on optical coherence tomography (OCT) is thought to be a collection of fibrous tissues and vascular networks that are identified in age-related macular degeneration (ARMD). We have carried out a retrospective analysis of 91 OCT scans of neovascular ARMD subtypes including classic and occult choroidal neovascularization (CNV) and retinal angiomatous proliferation (RAP). All three subtypes received ranibizumab, an anti-vascular endothelial growth factor (Anti-VEGF) intravitreal injections on an as-needed basis following the loading doses. Volumes of SHRM were calculated using caliper measurements of maximal height and length of SHRM seen on OCT. The ellipsoid formula derived from tumour models was used to calculate the volume. It was found that occult CNV and RAP have larger SHRM volumes than those of classic CNV. SHRM volumes reduced overall following loading doses of Anti-VEGF injections at 4 months in all three subtypes. However, a rebound increase in volume was noticed in both occult CNV and RAP cohort at 12 months despite the initial, steeper reductions in the subtypes. These findings were consistent with the data seen in volume measurement using Topcon's automated segmentation algorithm in a smaller cohort of patients. We propose that SHRM should be used as a potential biomarker to quantify both disease progression and prognosis of neovascular ARMD alongside other conventional methods.
Neurochemical and neuroanatomic effects of 3,4-methylenedioxymethamphetamine (MDMA) in rats
DOE Office of Scientific and Technical Information (OSTI.GOV)
Virus, R.; Commins, D.; Vosmer, G.
1986-03-05
Rats injected s.c. twice daily for 4 consecutive days with 10,20, or 40 mg/kg MDMA or saline and sacrificed 2 weeks after the last injection showed dose-dependent reductions in serotonin (5-HT) concentrations in hypothalamus, hippocampus (HIP), striatum (STR), somatosensory cortex (SC) and other cortical areas (CTX). 5-HT depletion was maximal in HIP (11.5 +/- 1.7%) and SC (15.3 +/- 3.2%, p<0.001 in both cases) at the 40 mg/kg MDMA dose. Forty mg/kg MDMA also reduced the amounts of dopamine (DA) in STR (78.2 +/- 6.4%, p<0.001) and of norepinephrine (NE) in HIP (74.5 +/- 6.4%, P<0.025) and CTX (77.9 +/-more » 6.1%, p<0.05). In addition, 20 mg/kg MDMA markedly reduced the number of (/sup 3/H)5-HT uptake sites (V/sub max/ 35.2% of control) without affecting the affinity (K/sub m/) in HIP. Fink-Heimer staining showed that rats injected s.c. twice daily for 2 days with 80 mg/kg MDMA had greater degeneration of nerve terminals in STR (p<0.005) and pyramidal cells in Layer III of SC (p<0.01) than did control rats. These results clearly suggest that repeated exposure to MDMA selectively damages serotonergic neurons in the central nervous system of rats.« less
Immediate effect of exercise on achilles tendon properties: systematic review.
Obst, Steven J; Barrett, Rod S; Newsham-West, Richard
2013-08-01
Understanding the mechanical and morphological adaptation of the Achilles tendon (AT) in response to acute exercise could have important implications for athletic performance, injury prevention, and rehabilitation. The purpose of this study was to conduct a systematic review and critical evaluation of the literature to determine the immediate effect of a single bout of exercise on the mechanical and morphological properties of the AT in vivo. Five electronic research databases were systematically searched for intervention-based studies reporting mechanical and morphological properties of the AT after a single bout of exercise. Searches revealed 3292 possible articles; 21 met the inclusion criteria. There is evidence that maximal isometric contractions and prolonged static stretching (>5 min) of the triceps surae complex cause an immediate decrease in AT stiffness, whereas prolonged running and hopping have minimal effect. Limited but consistent evidence exists, indicating that AT hysteresis is reduced after prolonged static stretching. Consistent evidence supports a reduction in free AT diameter (anterior-posterior) after dynamic ankle exercise, and this change appears most pronounced in the healthy tendon and after eccentric exercise. The mechanical and morphological properties of the AT in vivo are affected by acute exercise in a mode- and dose-dependent manner. Transient changes in AT stiffness, hysteresis, and diameter after unaccustomed exercise modes and doses may expose the tendon to increased risk of strain injury and impact on the mechanical function of the triceps surae muscle-tendon unit.
Kakamu, Takeyasu; Kanda, Hideyuki; Tsuji, Masayoshi; Kobayashi, Daisuke; Miyake, Masao; Hayakawa, Takehito; Katsuda, Shin-ichiro; Mori, Yayoi; Okouchi, Toshiyasu; Hazama, Akihiro; Fukushima, Tetsuhito
2013-01-01
After the Great East Japan Earthquake on 11 March 2011, the environmental radiation dose in Fukushima City increased. On 11 April, 1 mo after the earthquake, the environmental radiation dose rate at various surfaces in the same area differed greatly by surface property. Environmental radiation measurements continue in order to determine the estimated time to 50% reduction in environmental radiation dose rates by surface property in order to make suggestions for decontamination in Fukushima. The measurements were carried out from 11 April to 11 November 2011. Forty-eight (48) measurement points were selected, including four kinds of ground surface properties: grass (13), soil (5), artificial turf (7), and asphalt (23). Environmental radiation dose rate was measured at heights of 100 cm above the ground surface. Time to 50% reduction of environmental radiation dose rates was estimated for each ground surface property. Radiation dose rates on 11 November had decreased significantly compared with those on 11 April for all surface properties. Artificial turf showed the longest time to 50% reduction (544.32 d, standard error: 96.86), and soil showed the shortest (213.20 d, standard error: 35.88). The authors found the environmental radiation dose rate on artificial materials to have a longer 50% reduction time than that on natural materials. These results contribute to determining an order of priority for decontamination after nuclear disasters.
A study on the indirect urea dosing method in the Selective Catalytic Reduction system
NASA Astrophysics Data System (ADS)
Brzeżański, M.; Sala, R.
2016-09-01
This article presents the results of studies on concept solution of dosing urea in a gas phase in a selective catalytic reduction system. The idea of the concept was to heat-up and evaporate the water urea solution before introducing it into the exhaust gas stream. The aim was to enhance the processes of urea converting into ammonia, what is the target reductant for nitrogen oxides treatment. The study was conducted on a medium-duty Euro 5 diesel engine with exhaust line consisting of DOC catalyst, DPF filter and an SCR system with a changeable setup allowing to dose the urea in liquid phase (regular solution) and to dose it in a gas phase (concept solution). The main criteria was to assess the effect of physical state of urea dosed on the NOx conversion ratio in the SCR catalyst. In order to compare both urea dosing methods a special test procedure was developed which consisted of six test steps covering a wide temperature range of exhaust gas generated at steady state engine operation condition. Tests were conducted for different urea dosing quantities defined by the a equivalence ratio. Based on the obtained results, a remarkable improvement in NOx reduction was found for gas urea application in comparison to the standard liquid urea dosing. Measured results indicate a high potential to increase an efficiency of the SCR catalyst by using a gas phase urea and provide the basis for further scientific research on this type of concept.
Carvalho-Peixoto, Jacqueline; Moura, Mirian Ribeiro Leite; Cunha, Felipe Amorim; Lollo, Pablo Christiano B; Monteiro, Walace David; Carvalho, Lucia Maria Jaeger de; Farinatti, Paulo de Tarso Veras
2015-07-01
The study analyzed the effect of an açai (Euterpe oleracea Mart.) functional beverage (AB) on muscle and oxidative stress markers, cardiorespiratory responses, perceived exertion, and time-to-exhaustion during maximal treadmill running. The beverage was developed as an ergogenic aid for athletes and contained 27.6 mg of anthocyanins per dose. Fourteen athletes performed 3 exercise tests: a ramp-incremental maximal exercise test and 2 maximal exercise bouts performed in 2 conditions (AB and without AB (control)) at 90% maximal oxygen uptake. Blood was collected at baseline and after maximal exercise in both conditions to determine biomarkers. AB increased time to exhaustion during short-term high-intensity exercise (mean difference: 69 s, 95% confidence interval = -296 s to 159 s, t = 2.2, p = 0.045), attenuating the metabolic stress induced by exercise (p < 0.05). AB also reduced perceived exertion and enhanced cardiorespiratory responses (p < 0.05). The AB may be a useful and practical ergogenic aid to enhance performance during high-intensity training.
Yasaka, Koichiro; Katsura, Masaki; Akahane, Masaaki; Sato, Jiro; Matsuda, Izuru; Ohtomo, Kuni
2013-12-01
To evaluate dose reduction and image quality of abdominopelvic computed tomography (CT) reconstructed with model-based iterative reconstruction (MBIR) compared to adaptive statistical iterative reconstruction (ASIR). In this prospective study, 85 patients underwent referential-, low-, and ultralow-dose unenhanced abdominopelvic CT. Images were reconstructed with ASIR for low-dose (L-ASIR) and ultralow-dose CT (UL-ASIR), and with MBIR for ultralow-dose CT (UL-MBIR). Image noise was measured in the abdominal aorta and iliopsoas muscle. Subjective image analyses and a lesion detection study (adrenal nodules) were conducted by two blinded radiologists. A reference standard was established by a consensus panel of two different radiologists using referential-dose CT reconstructed with filtered back projection. Compared to low-dose CT, there was a 63% decrease in dose-length product with ultralow-dose CT. UL-MBIR had significantly lower image noise than L-ASIR and UL-ASIR (all p<0.01). UL-MBIR was significantly better for subjective image noise and streak artifacts than L-ASIR and UL-ASIR (all p<0.01). There were no significant differences between UL-MBIR and L-ASIR in diagnostic acceptability (p>0.65), or diagnostic performance for adrenal nodules (p>0.87). MBIR significantly improves image noise and streak artifacts compared to ASIR, and can achieve radiation dose reduction without severely compromising image quality.
CT Fluoroscopy Shielding: Decreases in Scattered Radiation for the Patient and Operator
Neeman, Ziv; Dromi, Sergio A.; Sarin, Shawn; Wood, Bradford J.
2008-01-01
PURPOSE High-radiation exposure occurs during computed tomographic (CT) fluoroscopy. Patient and operator doses during thoracic and abdominal interventional procedures were studied in the present experiment, and a novel shielding device to reduce exposure to the patient and operator was evaluated. MATERIALS AND METHODS With a 16-slice CT scanner in CT fluoroscopy mode (120 kVp, 30 mA), surface dosimetry was performed on adult and pediatric phantoms. The shielding was composed of tungsten antimony in the form of a lightweight polymer sheet. Doses to the patient were measured with and without shielding for thoracic and abdominal procedures. Doses to the operator were recorded with and without phantom, gantry, and table shielding in place. Double-layer lead-free gloves were used by the operator during the procedures. RESULTS Tungsten antimony shielding adjacent to the scan plane resulted in a maximum dose reduction of 92.3% to the patient. Maximum 85.6%, 93.3%, and 85.1% dose reductions were observed for the operator’s torso, gonads, and hands, respectively. The use of double-layer lead-free gloves resulted in a maximum radiation dose reduction of 97%. CONCLUSIONS Methods to reduce exposure during CT fluoroscopy are effective and should be searched for. Significant reduction in radiation doses to the patient and operator can be accomplished with tungsten antimony shielding. PMID:17185699
Effects of dose reduction on bone strength prediction using finite element analysis
NASA Astrophysics Data System (ADS)
Anitha, D.; Subburaj, Karupppasamy; Mei, Kai; Kopp, Felix K.; Foehr, Peter; Noel, Peter B.; Kirschke, Jan S.; Baum, Thomas
2016-12-01
This study aimed to evaluate the effect of dose reduction, by means of tube exposure reduction, on bone strength prediction from finite-element (FE) analysis. Fresh thoracic mid-vertebrae specimens (n = 11) were imaged, using multi-detector computed tomography (MDCT), at different intensities of X-ray tube exposures (80, 150, 220 and 500 mAs). Bone mineral density (BMD) was estimated from the mid-slice of each specimen from MDCT images. Differences in image quality and geometry of each specimen were measured. FE analysis was performed on all specimens to predict fracture load. Paired t-tests were used to compare the results obtained, using the highest CT dose (500 mAs) as reference. Dose reduction had no significant impact on FE-predicted fracture loads, with significant correlations obtained with reference to 500 mAs, for 80 mAs (R2 = 0.997, p < 0.001), 150 mAs (R2 = 0.998, p < 0.001) and 220 mAs (R2 = 0.987, p < 0.001). There were no significant differences in volume quantification between the different doses examined. CT imaging radiation dose could be reduced substantially to 64% with no impact on strength estimates obtained from FE analysis. Reduced CT dose will enable early diagnosis and advanced monitoring of osteoporosis and associated fracture risk.
Physics considerations in MV-CBCT multi-layer imager design.
Hu, Yue-Houng; Fueglistaller, Rony; Myronakis, Marios E; Rottmann, Joerg; Wang, Adam; Shedlock, Daniel; Morf, Daniel; Baturin, Paul; Huber, Pascal; Star-Lack, Josh M; Berbeco, Ross I
2018-05-30
Megavoltage (MV) cone-beam computed tomography (CBCT) using an electronic portal imaging (EPID) offers advantageous features, including 3D mapping, treatment beam registration, high-z artifact suppression, and direct radiation dose calculation. Adoption has been slowed by image quality limitations and concerns about imaging dose. Developments in imager design, including pixelated scintillators, structured phosphors, inexpensive scintillation materials, and multi-layer imager (MLI) architecture have been explored to improve EPID image quality and reduce imaging dose. The present study employs a hybrid Monte Carlo and linear systems model to determine the effect of detector design elements, such as multi-layer architecture and scintillation materials. We follow metrics of image quality including modulation transfer function (MTF) and noise power spectrum (NPS) from projection images to 3D reconstructions to in-plane slices and apply a task based figure-of-merit, the ideal observer signal-to-noise ratio (d') to determine the effect of detector design on object detectability. Generally, detectability was limited by detector noise performance. Deploying an MLI imager with a single scintillation material for all layers yields improvement in noise performance and d' linear with the number of layers. In general, improving x-ray absorption using thicker scintillators results in improved DQE(0). However, if light yield is low, performance will be affected by electronic noise at relatively high doses, resulting in rapid image quality degradation. Maximizing image quality in a heterogenous MLI detector (i.e. multiple different scintillation materials) is most affected by limiting imager noise. However, while a second-order effect, maximizing total spatial resolution of the MLI detector is a balance between the intensity contribution of each layer against its individual MTF. So, while a thinner scintillator may yield a maximal individual-layer MTF, its quantum efficiency will be relatively low in comparison to a thicker scintillator and thus, intensity contribution may be insufficient to noticeably improve the total detector MTF. © 2018 Institute of Physics and Engineering in Medicine.
Lilja, M; Mandić, M; Apró, W; Melin, M; Olsson, K; Rosenborg, S; Gustafsson, T; Lundberg, T R
2018-02-01
This study tested the hypothesis that high doses of anti-inflammatory drugs would attenuate the adaptive response to resistance training compared with low doses. Healthy men and women (aged 18-35 years) were randomly assigned to daily consumption of ibuprofen (IBU; 1200 mg; n = 15) or acetylsalicylic acid (ASA; 75 mg; n = 16) for 8 weeks. During this period, subjects completed supervised knee-extensor resistance training where one leg was subjected to training with maximal volitional effort in each repetition using a flywheel ergometer (FW), while the other leg performed conventional (work-matched across groups) weight-stack training (WS). Before and after training, muscle volume (MRI) and strength were assessed, and muscle biopsies were analysed for gene and protein expression of muscle growth regulators. The increase in m. quadriceps volume was similar between FW and WS, yet was (averaged across legs) greater in ASA (7.5%) compared with IBU (3.7%, group difference 34 cm 3 ; P = 0.029). In the WS leg, muscle strength improved similarly (11-20%) across groups. In the FW leg, increases (10-23%) in muscle strength were evident in both groups yet they were generally greater (interaction effects P < 0.05) for ASA compared with IBU. While our molecular analysis revealed several training effects, the only group interaction (P < 0.0001) arose from a downregulated mRNA expression of IL-6 in IBU. Maximal over-the-counter doses of ibuprofen attenuate strength and muscle hypertrophic adaptations to 8 weeks of resistance training in young adults. Thus, young individuals using resistance training to maximize muscle growth or strength should avoid excessive intake of anti-inflammatory drugs. © 2017 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.
Dubois, A E J; Pagliarani, G; Brouwer, R M; Kollen, B J; Dragsted, L O; Eriksen, F D; Callesen, O; Gilissen, L J W J; Krens, F A; Visser, R G F; Smulders, M J M; Vlieg-Boerstra, B J; Flokstra-de Blok, B J; van de Weg, W E
2015-11-01
Genetic modification of allergenic foods such as apple has the potential to reduce their clinical allergenicity, but this has never been studied by oral challenges in allergic individuals. We performed oral food challenges in 21 apple-allergic individuals with Elstar apples which had undergone gene silencing of the major allergen of apple, Mal d 1, by RNA interference. Downregulation of Mal d 1 gene expression in the apples was verified by qRT-PCR. Clinical responses to the genetically modified apples were compared to those seen with the wild-type Elstar using a visual analogue scale (VAS). Gene silencing produced two genetically modified apple lines expressing Mal d 1.02 and other Mal d 1 gene mRNA levels which were extensively downregulated, that is only 0.1-16.4% (e-DR1) and 0.2-9.9% (e-DR2) of those of the wild-type Elstar, respectively. Challenges with these downregulated apple lines produced significantly less intense maximal symptoms to the first dose (Vmax1) than with Elstar (Vmax1 Elstar 3.0 mm vs 0.0 mm for e-DR1, P = 0.017 and 0.0 mm for e-DR2, P = 0.043), as well as significantly less intense mean symptoms per dose (meanV/d) than with Elstar (meanV/d Elstar 2.2 mm vs 0.2 mm for e-DR1, P = 0.017 and 0.0 mm for e-DR2, P = 0.043). Only one subject (5%) remained symptom-free when challenged with the Elstar apple, whereas 43% did so with e-DR1 and 63% with e-DR2. These data show that mRNA silencing of Mal d 1 results in a marked reduction of Mal d 1 gene expression in the fruit and reduction of symptoms when these apples are ingested by allergic subjects. Approximately half of the subjects developed no symptoms whatsoever, and virtually all subjects wished to consume the apple again in the future. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Pressurised metered dose inhaler-spacer technique in young children improves with video instruction.
Shaw, Nicole; Le Souëf, Peter; Turkovic, Lidija; McCahon, Lucy; Kicic, Anthony; Sly, Peter D; Devadason, Sunalene; Schultz, André
2016-07-01
The importance of good device technique to maximise delivery of aerosolised medications is widely recognised. Pressurised metered dose inhaler (pMDI)-spacer technique was investigated in 122 children, aged 2-7 years, with asthma. Eight individual steps of device technique were evaluated before and after viewing an instructional video for correct device technique. Video measurements were repeated every three months for nine months. Device technique improved directly after video instruction at the baseline study visit (p < 0.001) but had no immediate effect at subsequent visits. Additionally, pMDI-spacer technique improved with successive visits over one year for the group overall as evidenced by increases in the proportion of children scoring maximal (p = 0.02) and near-maximal (p = 0.04) scores. Repeated video instruction over time improves inhaler technique in young children. • Correct device technique is considered essential for sufficient delivery of inhaled medication. • Poor inhaler use is common in young asthmatic children using pressurised metered dose inhalers and spacers. What is New: • Video instruction could be used as a strategy to improve device technique in young children.
Estimating Likelihood of Fetal In Vivo Interactions Using In ...
Tox21/ToxCast efforts provide in vitro concentration-response data for thousands of compounds. Predicting whether chemical-biological interactions observed in vitro will occur in vivo is challenging. We hypothesize that using a modified model from the FDA guidance for drug interaction studies, Cmax/AC50 (i.e., maximal in vivo blood concentration over the half-maximal in in vitro activity concentration), will give a useful approximation for concentrations where in vivo interactions are likely. Further, for doses where maternal blood concentrations are likely to elicit an interaction (Cmax/AC50>0.1), where do the compounds accumulate in fetal tissues? In order to estimate these doses based on Tox21 data, in silico parameters of chemical fraction unbound in plasma and intrinsic hepatic clearance were estimated from ADMET predictor (Simulations-Plus Inc.) and used in the HTTK R-package to obtain Cmax values from a physiologically-based toxicokinetics model. In silico estimated Cmax values predicted in vivo human Cmax with median absolute error of 0.81 for 93 chemicals, giving confidence in the R-package and in silico estimates. A case example evaluating Cmax/AC50 values for peroxisome proliferator-activated receptor gamma (PPARγ) and glucocorticoid receptor revealed known compounds (glitazones and corticosteroids, respectively) highest on the list at pharmacological doses. Doses required to elicit likely interactions across all Tox21/ToxCast assays were compared to
Estepp, Jeremie H; Smeltzer, Matthew P; Kang, Guolian; Li, Chen; Wang, Winfred C; Abrams, Christina; Aygun, Banu; Ware, Russell E; Nottage, Kerri; Hankins, Jane S
2017-12-01
Hydroxyurea has proven clinical benefits and is recommended to be offered to all children with sickle cell anemia (SCA), but the optimal dosing regimen remains controversial. Induction of red blood cell fetal hemoglobin (HbF) by hydroxyurea appears to be dose-dependent. However, it is unknown whether maximizing HbF% improves clinical outcomes. HUSTLE (NCT00305175) is a prospective observational study with a primary goal of describing the long-term clinical effects of hydroxyurea escalated to maximal tolerated dose (MTD) in children with SCA. In 230 children, providing 610 patient-years of follow up, the mean attained HbF% at MTD was >20% for up to 4 years of follow-up. When HbF% values were ≤20%, children had twice the odds of hospitalization for any reason (P < .0001), including vaso-occlusive pain (P < .01) and acute chest syndrome (ACS) (P < .01), and more than four times the odds of admission for fever (P < .001). Thirty day readmission rates were not affected by HbF%. Neutropenia (ANC <1000 × 10 6 /L) was rare (2.3% of all laboratory monitoring), transient, and benign. Therefore, attaining HbF >20% was associated with fewer hospitalizations without significant toxicity. These data support the use of hydroxyurea in children, and suggest that the preferred dosing strategy is one that targets a HbF endpoint >20%. © 2017 Wiley Periodicals, Inc.
Method to monitor HC-SCR catalyst NOx reduction performance for lean exhaust applications
Viola, Michael B [Macomb Township, MI; Schmieg, Steven J [Troy, MI; Sloane, Thompson M [Oxford, MI; Hilden, David L [Shelby Township, MI; Mulawa, Patricia A [Clinton Township, MI; Lee, Jong H [Rochester Hills, MI; Cheng, Shi-Wai S [Troy, MI
2012-05-29
A method for initiating a regeneration mode in selective catalytic reduction device utilizing hydrocarbons as a reductant includes monitoring a temperature within the aftertreatment system, monitoring a fuel dosing rate to the selective catalytic reduction device, monitoring an initial conversion efficiency, selecting a determined equation to estimate changes in a conversion efficiency of the selective catalytic reduction device based upon the monitored temperature and the monitored fuel dosing rate, estimating changes in the conversion efficiency based upon the determined equation and the initial conversion efficiency, and initiating a regeneration mode for the selective catalytic reduction device based upon the estimated changes in conversion efficiency.
Subissi, A.; Guelfi, M.; Criscuoli, M.
1990-01-01
1. The effects of intravenous captopril and enalaprilic acid on the increase in pulmonary inflation pressure induced by different bronchoconstrictor agents were evaluated in the anaesthetized guinea-pig. 2. Captopril and enalaprilic acid (1.6-200 micrograms kg-1) enhanced dose-dependently the bronchoconstriction (BC) induced by substance P. The threshold effective dose was 1.6 micrograms kg-1 and maximal potentiation over the control response was more than 400% for both agents. Enalaprilic acid was also assayed for serum and lung angiotensin converting enzyme (ACE) inhibition in anaesthetized guinea-pigs. This drug produced a dose-dependent inhibition of ACE in both tissues, with ED50 s of 7.6 and 9.4 micrograms kg-1, respectively: this inhibitory activity was positively correlated to substance P potentiation. 3. Captopril (8-1000 micrograms kg-1) enhanced dose-dependently the BC induced by capsaicin. The threshold effective dose was 40 micrograms kg-1 and maximal potentiation about 90%. 4. Captopril (200-1000 micrograms kg-1) did not affect BC induced by bradykinin. However, this response was markedly enhanced (about 200%) by captopril 200 micrograms kg-1 in propranolol-pretreated animals. 5. Captopril and enalaprilic acid (200-1000 micrograms kg-1) slightly (20-40%) but significantly enhanced the BC induced by 5-hydroxytryptamine. However, this response was potentiated to the same extent by a dose of prazosin, which produced a degree of hypotension similar to that observed after administration of the ACE inhibitors. 6. In conclusion, ACE inhibitors potentiate the BC induced by substance P and, to a minor extent, that induced by capsaicin in the anaesthetized guinea-pig.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:1697196
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Young-Hoon; Department of Neurosurgery, Seoul National University College of Medicine, Seoul; Kim, Dong Gyu, E-mail: gknife@plaza.snu.ac.kr
2012-11-01
Purpose: This study was performed to assess the radiosurgical results of meningiomas extending into the internal acoustic canal (para-IAC meningiomas), with a particular focus on the effect of radiation dose to the cochlea on hearing outcome. Methods and Materials: A total of 50 patients who underwent radiosurgery for para-IAC meningiomas between 1998 and 2009, which were followed for 2 years, were enrolled. The mean age was 55.8 years (range, 15-75). The mean tumor volume was 6.1 cm{sup 3} (range, 1.0-19.0), the mean tumor length in the IAC was 6.9 mm (range, 1.3-13.3), and the mean prescribed marginal dose was 13.1more » Gy (range, 10-15) at an isodose line of 50%. The mean follow-up duration was 46 months (range, 24-122). Results: Eight (16.0%) patients had nonserviceable hearing at the time of surgery. At the last follow-up, the tumor control rate was 94%; unchanged in 17 patients, decreased in 30 patients, and increased in 3 patients. Among 42 patients with serviceable hearing at the time of radiosurgery, it was preserved in 41 (97.6%) patients at the last follow-up. The maximal and mean radiation doses to the cochleae of these 41 patients were 5.8 Gy {+-} 0.3 (range, 3.1-11.5) and 4.3 Gy {+-} 0.2 (range, 2.2-7.5), respectively. The maximal dose to the cochlea of the patient who lost hearing after radiosurgery was 4.7 Gy. Conclusions: The radiation dose to the cochlea may have the minimal toxic effect on the hearing outcome in patients who undergo radiosurgery for para-IAC meningiomas.« less
NASA Astrophysics Data System (ADS)
Londt, John H.; Shreter, Uri; Vass, Melissa; Hsieh, Jiang; Ge, Zhanyu; Adda, Olivier; Dowe, David A.; Sabllayrolles, Jean-Louis
2007-03-01
We present the results of dose and image quality performance evaluation of a novel, prospective ECG-gated Coronary CT Angiography acquisition mode (SnapShot Pulse, LightSpeed VCT-XT scanner, GE Healthcare, Waukesha, WI), and compare it to conventional retrospective ECG gated helical acquisition in clinical and phantom studies. Image quality phantoms were used to measure noise, slice sensitivity profile, in-plane resolution, low contrast detectability and dose, using the two acquisition modes. Clinical image quality and diagnostic confidence were evaluated in a study of 31 patients scanned with the two acquisition modes. Radiation dose reduction in clinical practice was evaluated by tracking 120 consecutive patients scanned with the prospectively gated scan mode. In the phantom measurements, the prospectively gated mode resulted in equivalent or better image quality measures at dose reductions of up to 89% compared to non-ECG modulated conventional helical scans. In the clinical study, image quality was rated excellent by expert radiologist reviewing the cases, with pathology being identical using the two acquisition modes. The average dose to patients in the clinical practice study was 5.6 mSv, representing 50% reduction compared to a similar patient population scanned with the conventional helical mode.
NASA Astrophysics Data System (ADS)
Setlur Nagesh, S. V.; Khobragade, P.; Ionita, C.; Bednarek, D. R.; Rudin, S.
2015-03-01
Because x-ray based image-guided vascular interventions are minimally invasive they are currently the most preferred method of treating disorders such as stroke, arterial stenosis, and aneurysms; however, the x-ray exposure to the patient during long image-guided interventional procedures could cause harmful effects such as cancer in the long run and even tissue damage in the short term. ROI fluoroscopy reduces patient dose by differentially attenuating the incident x-rays outside the region-of-interest. To reduce the noise in the dose-reduced regions previously recursive temporal filtering was successfully demonstrated for neurovascular interventions. However, in cardiac interventions, anatomical motion is significant and excessive recursive filtering could cause blur. In this work the effects of three noise-reduction schemes, including recursive temporal filtering, spatial mean filtering, and a combination of spatial and recursive temporal filtering, were investigated in a simulated ROI dose-reduced cardiac intervention. First a model to simulate the aortic arch and its movement was built. A coronary stent was used to simulate a bioprosthetic valve used in TAVR procedures and was deployed under dose-reduced ROI fluoroscopy during the simulated heart motion. The images were then retrospectively processed for noise reduction in the periphery, using recursive temporal filtering, spatial filtering and a combination of both. Quantitative metrics for all three noise reduction schemes are calculated and are presented as results. From these it can be concluded that with significant anatomical motion, a combination of spatial and recursive temporal filtering scheme is best suited for reducing the excess quantum noise in the periphery. This new noise-reduction technique in combination with ROI fluoroscopy has the potential for substantial patient-dose savings in cardiac interventions.
Kalra, Mannudeep K; Maher, Michael M; Blake, Michael A; Lucey, Brian C; Karau, Kelly; Toth, Thomas L; Avinash, Gopal; Halpern, Elkan F; Saini, Sanjay
2004-09-01
To assess the effect of noise reduction filters on detection and characterization of lesions on low-radiation-dose abdominal computed tomographic (CT) images. Low-dose CT images of abdominal lesions in 19 consecutive patients (11 women, eight men; age range, 32-78 years) were obtained at reduced tube currents (120-144 mAs). These baseline low-dose CT images were postprocessed with six noise reduction filters; the resulting postprocessed images were then randomly assorted with baseline images. Three radiologists performed independent evaluation of randomized images for presence, number, margins, attenuation, conspicuity, calcification, and enhancement of lesions, as well as image noise. Side-by-side comparison of baseline images with postprocessed images was performed by using a five-point scale for assessing lesion conspicuity and margins, image noise, beam hardening, and diagnostic acceptability. Quantitative noise and contrast-to-noise ratio were obtained for all liver lesions. Statistical analysis was performed by using the Wilcoxon signed rank test, Student t test, and kappa test of agreement. Significant reduction of noise was observed in images postprocessed with filter F compared with the noise in baseline nonfiltered images (P =.004). Although the number of lesions seen on baseline images and that seen on postprocessed images were identical, lesions were less conspicuous on postprocessed images than on baseline images. A decrease in quantitative image noise and contrast-to-noise ratio for liver lesions was noted with all noise reduction filters. There was good interobserver agreement (kappa = 0.7). Although the use of currently available noise reduction filters improves image noise and ameliorates beam-hardening artifacts at low-dose CT, such filters are limited by a compromise in lesion conspicuity and appearance in comparison with lesion conspicuity and appearance on baseline low-dose CT images. Copyright RSNA, 2004
Siochi, R Alfredo; Kim, Yusung; Bhatia, Sudershan
2014-10-16
We studied the feasibility of evaluating tumor control probability (TCP) reductions for tumor motion beyond planned gated radiotherapy margins. Tumor motion was determined from cone-beam CT projections acquired for patient setup, intrafraction respiratory traces, and 4D CTs for five non-small cell lung cancer (NSCLC) patients treated with gated radiotherapy. Tumors were subdivided into 1 mm sections whose positions and doses were determined for each beam-on time point. (The dose calculation model was verified with motion phantom measurements.) The calculated dose distributions were used to generate the treatment TCPs for each patient. The plan TCPs were calculated from the treatment planning dose distributions. The treatment TCPs were compared to the plan TCPs for various models and parameters. Calculated doses matched phantom measurements within 0.3% for up to 3 cm of motion. TCP reductions for excess motion greater than 5mm ranged from 1.7% to 11.9%, depending on model parameters, and were as high as 48.6% for model parameters that simulated an individual patient. Repeating the worst case motion for all fractions increased TCP reductions by a factor of 2 to 3, while hypofractionation decreased these reductions by as much as a factor of 3. Treatment motion exceeding gating margins by more than 5 mm can lead to considerable TCP reductions. Appropriate margins for excess motion are recommended, unless applying daily tumor motion verification and adjusting thegating window.
Bi, Jian
2010-01-01
As the desire to promote health increases, reductions of certain ingredients, for example, sodium, sugar, and fat in food products, are widely requested. However, the reduction is not risk free in sensory and marketing aspects. Over reduction may change the taste and influence the flavor of a product and lead to a decrease in consumer's overall liking or purchase intent for the product. This article uses the benchmark dose (BMD) methodology to determine an appropriate reduction. Calculations of BMD and one-sided lower confidence limit of BMD are illustrated. The article also discusses how to calculate BMD and BMDL for over dispersed binary data in replicated testing based on a corrected beta-binomial model. USEPA Benchmark Dose Software (BMDS) were used and S-Plus programs were developed. The method discussed in the article is originally used to determine an appropriate reduction of certain ingredients, for example, sodium, sugar, and fat in food products, considering both health reason and sensory or marketing risk.
ERIC Educational Resources Information Center
Naisteter, Michal A.; Sitron, Justin A.
2010-01-01
This article explores the potential for introducing harm reduction into sexuality education. When the goal of sexuality education is on prevention and focuses on risk and public health concerns, a discussion of pleasure is rendered problematic, as many pleasurable behaviors are inherently "unsafe" or "risky" when considered using a safe-sex lens.…
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, Lifeng; Liu, Xin; Leng, Shuai; Kofler, James M; Ramirez-Giraldo, Juan C; Qu, Mingliang; Christner, Jodie; Fletcher, Joel G; McCollough, Cynthia H
2011-01-01
Despite universal consensus that computed tomography (CT) overwhelmingly benefits patients when used for appropriate indications, concerns have been raised regarding the potential risk of cancer induction from CT due to the exponentially increased use of CT in medicine. Keeping radiation dose as low as reasonably achievable, consistent with the diagnostic task, remains the most important strategy for decreasing this potential risk. This article summarizes the general technical strategies that are commonly used for radiation dose management in CT. Dose-management strategies for pediatric CT, cardiac CT, dual-energy CT, CT perfusion and interventional CT are specifically discussed, and future perspectives on CT dose reduction are presented. PMID:22308169
Paoloni, Melissa C.; Mazcko, Christina; Fox, Elizabeth; Fan, Timothy; Lana, Susan; Kisseberth, William; Vail, David M.; Nuckolls, Kaylee; Osborne, Tanasa; Yalkowsy, Samuel; Gustafson, Daniel; Yu, Yunkai; Cao, Liang; Khanna, Chand
2010-01-01
Background Signaling through the mTOR pathway contributes to growth, progression and chemoresistance of several cancers. Accordingly, inhibitors have been developed as potentially valuable therapeutics. Their optimal development requires consideration of dose, regimen, biomarkers and a rationale for their use in combination with other agents. Using the infrastructure of the Comparative Oncology Trials Consortium many of these complex questions were asked within a relevant population of dogs with osteosarcoma to inform the development of mTOR inhibitors for future use in pediatric osteosarcoma patients. Methodology/Principal Findings This prospective dose escalation study of a parenteral formulation of rapamycin sought to define a safe, pharmacokinetically relevant, and pharmacodynamically active dose of rapamycin in dogs with appendicular osteosarcoma. Dogs entered into dose cohorts consisting of 3 dogs/cohort. Dogs underwent a pre-treatment tumor biopsy and collection of baseline PBMC. Dogs received a single intramuscular dose of rapamycin and underwent 48-hour whole blood pharmacokinetic sampling. Additionally, daily intramuscular doses of rapamycin were administered for 7 days with blood rapamycin trough levels collected on Day 8, 9 and 15. At Day 8 post-treatment collection of tumor and PBMC were obtained. No maximally tolerated dose of rapamycin was attained through escalation to the maximal planned dose of 0.08 mg/kg (2.5 mg/30kg dog). Pharmacokinetic analysis revealed a dose-dependent exposure. In all cohorts modulation of the mTOR pathway in tumor and PBMC (pS6RP/S6RP) was demonstrated. No change in pAKT/AKT was seen in tumor samples following rapamycin therapy. Conclusions/Significance Rapamycin may be safely administered to dogs and can yield therapeutic exposures. Modulation pS6RP/S6RP in tumor tissue and PBMCs was not dependent on dose. Results from this study confirm that the dog may be included in the translational development of rapamycin and potentially other mTOR inhibitors. Ongoing studies of rapamycin in dogs will define optimal schedules for their use in cancer and evaluate the role of rapamycin use in the setting of minimal residual disease. PMID:20543980
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, E; Yuan, F; Templeton, A
Purpose: The ultimate goal of radiotherapy treatment planning is to find a treatment that will yield a high tumor-control-probability(TCP) with an acceptable normal-tissue-complication probability(NTCP). Yet most treatment planning today is not based upon optimization of TCPs and NTCPs, but rather upon meeting physical dose and volume constraints defined by the planner. We design treatment plans that optimize TCP directly and contrast them with the clinical dose-based plans. PET image is incorporated to evaluate gain in TCP for dose escalation. Methods: We build a nonlinear mixed integer programming optimization model that maximizes TCP directly while satisfying the dose requirements on themore » targeted organ and healthy tissues. The solution strategy first fits the TCP function with a piecewise-linear approximation, then solves the problem that maximizes the piecewise linear approximation of TCP, and finally performs a local neighborhood search to improve the TCP value. To gauge the feasibility, characteristics, and potential benefit of PET-image guided dose escalation, initial validation consists of fifteen cervical cancer HDR patient cases. These patients have all received prior 45Gy of external radiation dose. For both escalated strategies, we consider 35Gy PTV-dose, and two variations (37Gy-boost to BTV vs 40Gy-boost) to PET-image-pockets. Results: TCP for standard clinical plans range from 59.4% - 63.6%. TCP for dose-based PET-guided escalated-dose-plan ranges from 63.8%–98.6% for all patients; whereas TCP-optimized plans achieves over 91% for all patients. There is marginal difference in TCP among those with 37Gy-boosted vs 40Gy-boosted. There is no increase in rectum and bladder dose among all plans. Conclusion: Optimizing TCP directly results in highly conformed treatment plans. The TCP-optimized plan is individualized based on the biological PET-image of the patients. The TCP-optimization framework is generalizable and has been applied successfully to other external-beam delivery modalities. A clinical trial is on-going to gauge the clinical significance. Partially supported by the National Science Foundation.« less
Collery, Philippe; Santoni, François; Ciccolini, Joseph; Tran, Thi Ngoc Nga; Mohsen, Ahmed; Desmaele, Didier
2016-11-01
Rhenium (I)-diselenoether has shown promising antiproliferative efficacy in both in vitro and in vivo models. However, the maximal tolerated dose and dose-effect relationships have not been fully addressed for this compound. Here, we evaluated the tolerance and efficacy of three dose-levels (namely 10, 40 and 100 mg/kg) intraperitoneally administered daily over 28 days in mice bearing the resistant MDA-MB231 breast cancer cell line. The upper dose was found to be toxic and was reduced to 60 mg/kg. The 10 mg/kg dose well tolerated, whereas 40 mg/kg was associated with 10% mortality (LD 10 ). Both 10 and 40 mg/kg dosing achieved a significantly similar regression of tumor growth compared with untreated animals. This study suggests that 10 mg/kg daily is the recommended dose for rhenium (I) diselenoether. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Papaleo, Enrico; Zaffagnini, Stefano; Munaretto, Maria; Vanni, Valeria Stella; Rebonato, Giorgia; Grisendi, Valentina; Di Paola, Rossana; La Marca, Antonio
2016-12-01
To externally validate a nomogram based on ovarian reserve markers as a tool to optimize the FSH starting dose in IVF/ICSI cycles. A two-centres retrospective study including 398 infertile women undergoing their first IVF/ICSI cycle (June 2013-June 2014). IVF data were retrieved from two independent IVF centres in Italy (San Raffaele Hospital, Centre 1; Verona Hospital, Centre 2). A central lab for the routine measurement of AMH and FSH was used for both centres. All women were treated based on physical and hormonal characteristics according to locally adopted protocols. The nomogram was then retrospectively applied to the patients comparing the calculated starting dose to the one actually given. In Centre 1, 64/131 women (48.8%) had an ovarian response below the target. While 45 of these patients were treated with a maximal FSH starting dose (≥225 IU), n=19/131 (14.5%) were treated with a submaximal dose. The vast majority of them (n=17/19) would have received a higher FSH starting dose by using the nomogram. Seventeen patients (n=17/131) had hyper response and about half of them would have been treated with a reduced FSH starting dose according to the nomogram. In Centre 2, 142/267 patients (53.2%) had an ovarian response below the target. While 136 of these were treated with a maximal FSH starting dose (≥225 IU), n=6/267 were treated with a submaximal dose. The majority of them (n=5/6) would have received a higher FSH starting dose. Thirty-two (n=32/267) patients had hyper response and more than half of them would have been treated with a reduced FSH dose. In both Centres, applying the nomogram would have resulted in more appropriate FSH starting doses compared to the the ones actually given based on clinicians choices. The use of an objective algorithm based on patient's age, serum FSH and AMH levels may thus be an effective advice on the selection of the tailored FSH starting dose. Hence, the use of this easily available nomogram could increase the proportion of patients achieving the optimal ovarian response. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tom, Nathan M.; Yu, Yi -Hsiang; Wright, Alan D.
The aim of this study is to describe a procedure to maximize the power-to-load ratio of a novel wave energy converter (WEC) that combines an oscillating surge wave energy converter with variable structural components. The control of the power-take-off torque will be on a wave-to-wave timescale, whereas the structure will be controlled statically such that the geometry remains the same throughout the wave period. Linear hydrodynamic theory is used to calculate the upper and lower bounds for the time-averaged absorbed power and surge foundation loads while assuming that the WEC motion remains sinusoidal. Previous work using pseudo-spectral techniques to solvemore » the optimal control problem focused solely on maximizing absorbed energy. This work extends the optimal control problem to include a measure of the surge foundation force in the optimization. The objective function includes two competing terms that force the optimizer to maximize power capture while minimizing structural loads. A penalty weight was included with the surge foundation force that allows control of the optimizer performance based on whether emphasis should be placed on power absorption or load shedding. Results from pseudo-spectral optimal control indicate that a unit reduction in time-averaged power can be accompanied by a greater reduction in surge-foundation force.« less
Tom, Nathan M.; Yu, Yi -Hsiang; Wright, Alan D.; ...
2017-04-18
The aim of this study is to describe a procedure to maximize the power-to-load ratio of a novel wave energy converter (WEC) that combines an oscillating surge wave energy converter with variable structural components. The control of the power-take-off torque will be on a wave-to-wave timescale, whereas the structure will be controlled statically such that the geometry remains the same throughout the wave period. Linear hydrodynamic theory is used to calculate the upper and lower bounds for the time-averaged absorbed power and surge foundation loads while assuming that the WEC motion remains sinusoidal. Previous work using pseudo-spectral techniques to solvemore » the optimal control problem focused solely on maximizing absorbed energy. This work extends the optimal control problem to include a measure of the surge foundation force in the optimization. The objective function includes two competing terms that force the optimizer to maximize power capture while minimizing structural loads. A penalty weight was included with the surge foundation force that allows control of the optimizer performance based on whether emphasis should be placed on power absorption or load shedding. Results from pseudo-spectral optimal control indicate that a unit reduction in time-averaged power can be accompanied by a greater reduction in surge-foundation force.« less
Low radiation dose in computed tomography: the role of iodine
Aschoff, Andrik J; Catalano, Carlo; Krix, Martin; Albrecht, Thomas
2017-01-01
Recent approaches to reducing radiation exposure during CT examinations typically utilize automated dose modulation strategies on the basis of lower tube voltage combined with iterative reconstruction and other dose-saving techniques. Less clearly appreciated is the potentially substantial role that iodinated contrast media (CM) can play in low-radiation-dose CT examinations. Herein we discuss the role of iodinated CM in low-radiation-dose examinations and describe approaches for the optimization of CM administration protocols to further reduce radiation dose and/or CM dose while maintaining image quality for accurate diagnosis. Similar to the higher iodine attenuation obtained at low-tube-voltage settings, high-iodine-signal protocols may permit radiation dose reduction by permitting a lowering of mAs while maintaining the signal-to-noise ratio. This is particularly feasible in first pass examinations where high iodine signal can be achieved by injecting iodine more rapidly. The combination of low kV and IR can also be used to reduce the iodine dose. Here, in optimum contrast injection protocols, the volume of CM administered rather than the iodine concentration should be reduced, since with high-iodine-concentration CM further reductions of iodine dose are achievable for modern first pass examinations. Moreover, higher concentrations of CM more readily allow reductions of both flow rate and volume, thereby improving the tolerability of contrast administration. PMID:28471242
Younger, Jarred; Noor, Noorulain; McCue, Rebecca; Mackey, Sean
2013-02-01
To determine whether low dosages (4.5 mg/day) of naltrexone reduce fibromyalgia severity as compared with the nonspecific effects of placebo. In this replication and extension study of a previous clinical trial, we tested the impact of low-dose naltrexone on daily self-reported pain. Secondary outcomes included general satisfaction with life, positive mood, sleep quality, and fatigue. Thirty-one women with fibromyalgia participated in the randomized, double-blind, placebo-controlled, counterbalanced, crossover study. During the active drug phase, participants received 4.5 mg of oral naltrexone daily. An intensive longitudinal design was used to measure daily levels of pain. When contrasting the condition end points, we observed a significantly greater reduction of baseline pain in those taking low-dose naltrexone than in those taking placebo (28.8% reduction versus 18.0% reduction; P = 0.016). Low-dose naltrexone was also associated with improved general satisfaction with life (P = 0.045) and with improved mood (P = 0.039), but not improved fatigue or sleep. Thirty-two percent of participants met the criteria for response (defined as a significant reduction in pain plus a significant reduction in either fatigue or sleep problems) during low-dose naltrexone therapy, as contrasted with an 11% response rate during placebo therapy (P = 0.05). Low-dose naltrexone was rated equally tolerable as placebo, and no serious side effects were reported. The preliminary evidence continues to show that low-dose naltrexone has a specific and clinically beneficial impact on fibromyalgia pain. The medication is widely available, inexpensive, safe, and well-tolerated. Parallel-group randomized controlled trials are needed to fully determine the efficacy of the medication. Copyright © 2013 by the American College of Rheumatology.
Florek-Luszczki, Magdalena; Zagaja, Miroslaw; Luszczki, Jarogniew J
2015-08-01
The influence of arachidonyl-2'-chloroethylamide (ACEA - a selective cannabinoid CB1 receptor agonist) on the anticonvulsant potency and acute adverse-effect potentials of clobazam, lacosamide, and pregabalin was determined in the maximal electroshock-induced seizure model and chimney test in mice. ACEA (2.5 mg/kg, i.p.) significantly enhanced the anticonvulsant potency of pregabalin in the mouse maximal electroshock-induced seizure model by decreasing the median effective dose (ED50 ) of pregabalin from 125.39 to 78.06 mg/kg (P < 0.05). In contrast, ACEA (2.5 mg/kg) had no significant impact on the anticonvulsant potency of clobazam and lacosamide in the mouse maximal electroshock-induced seizure model. On the other hand, ACEA (2.5 mg/kg) did not affect acute adverse effects of clobazam, lacosamide or pregabalin, and the median toxic doses (TD50 ) for the studied anti-epileptic drugs in combination with ACEA did not differ from the TD50 values as determined for the drugs administered alone in the chimney test. In conclusion, ACEA ameliorates the pharmacological profile of pregabalin, when considering both the anticonvulsant and the acute adverse effects of the drug in preclinical study on animals. The combination of pregabalin with ACEA can be of pivotal importance for patients with epilepsy as a potentially advantageous combination if the results from this study translate into clinical settings. © 2015 Société Française de Pharmacologie et de Thérapeutique.
Diaz-Lara, Francisco Javier; Del Coso, Juan; Portillo, Javier; Areces, Francisco; García, Jose Manuel; Abián-Vicén, Javier
2016-10-01
Although caffeine is one of the most commonly used substances in combat sports, information about its ergogenic effects on these disciplines is very limited. To determine the effectiveness of ingesting a moderate dose of caffeine to enhance overall performance during a simulated Brazilian jiu-jitsu (BJJ) competition. Fourteen elite BJJ athletes participated in a double-blind, placebo-controlled experimental design. In a random order, the athletes ingested either 3 mg/kg body mass of caffeine or a placebo (cellulose, 0 mg/kg) and performed 2 simulated BJJ combats (with 20 min rest between them), following official BJJ rules. Specific physical tests such as maximal handgrip dynamometry, maximal height during a countermovement jump, permanence during a maximal static-lift test, peak power in a bench-press exercise, and blood lactate concentration were measured at 3 specific times: before the first combat and immediately after the first and second combats. The combats were video-recorded to analyze fight actions. After the caffeine ingestion, participants spent more time in offensive actions in both combats and revealed higher blood lactate values (P < .05). Performance in all physical tests carried out before the first combat was enhanced with caffeine (P < .05), and some improvements remained after the first combat (eg, maximal static-lift test and bench-press exercise; P < .05). After the second combat, the values in all physical tests were similar between caffeine and placebo. Caffeine might be an effective ergogenic aid for improving intensity and physical performance during successive elite BJJ combats.
Deist, T M; Gorissen, B L
2016-02-07
High-dose-rate brachytherapy is a tumor treatment method where a highly radioactive source is brought in close proximity to the tumor. In this paper we develop a simulated annealing algorithm to optimize the dwell times at preselected dwell positions to maximize tumor coverage under dose-volume constraints on the organs at risk. Compared to existing algorithms, our algorithm has advantages in terms of speed and objective value and does not require an expensive general purpose solver. Its success mainly depends on exploiting the efficiency of matrix multiplication and a careful selection of the neighboring states. In this paper we outline its details and make an in-depth comparison with existing methods using real patient data.
Grebenstein, Patricia; Burroughs, Danielle; Zhang, Yan; LeSage, Mark G.
2013-01-01
Reducing the nicotine content in tobacco products is being considered by the FDA as a policy to reduce the addictiveness of tobacco products. Understanding individual differences in response to nicotine reduction will be critical to developing safe and effective policy. Animal and human research demonstrating sex differences in the reinforcing effects of nicotine suggests that males and females may respond differently to nicotine-reduction policies. However, no studies have directly examined sex differences in the effects of nicotine unit-dose reduction on nicotine self-administration (NSA) in animals. The purpose of the present study was to examine this issue in a rodent self-administration model. Male and female rats were trained to self-administer nicotine (0.06 mg/kg) under an FR 3 schedule during daily 23 h sessions. Rats were then exposed to saline extinction and reacquisition of NSA, followed by weekly reductions in the unit dose (0.03 to 0.00025 mg/kg) until extinction levels of responding were achieved. Males and females were compared with respect to baseline levels of intake, resistance to extinction, degree of compensatory increases in responding during dose reduction, and the threshold reinforcing unit dose of nicotine. Exponential demand-curve analysis was also conducted to compare the sensitivity of males and females to increases in the unit price (FR/unit dose) of nicotine (i.e., elasticity of demand or reinforcing efficacy). Females exhibited significantly higher baseline intake and less compensation than males. However, there were no sex differences in the reinforcement threshold or elasticity of demand. Dose–response relationships were very well described by the exponential demand function (r2 values > 0.96 for individual subjects). These findings suggest that females may exhibit less compensatory smoking in response to nicotine reduction policies, even though their nicotine reinforcement threshold and elasticity of demand may not differ from males. PMID:24201048
Spring, Jérôme Nicolas; Place, Nicolas; Borrani, Fabio; Kayser, Bengt; Barral, Jérôme
2016-01-01
Exercise-induced fatigue affects the motor control and the ability to generate a given force or power. Surface electroencephalography allows researchers to investigate movement-related cortical potentials (MRCP), which reflect preparatory brain activity 1.5 s before movement onset. Although the MRCP amplitude appears to increase after repetitive single-joint contractions, the effects of large-muscle group dynamic exercise on such pre-motor potential remain to be described. Sixteen volunteers exercised 30 min at 60% of the maximal aerobic power on a cycle ergometer, followed by a 10-km all-out time trial. Before and after each of these tasks, knee extensor neuromuscular function was investigated using maximal voluntary contractions (MVC) combined with electrical stimulations of the femoral nerve. MRCP was recorded during 60 knee extensions after each neuromuscular sequence. The exercise resulted in a significant decrease in the knee extensor MVC force after the 30-min exercise (−10 ± 8%) and the time trial (−21 ± 9%). The voluntary activation level (VAL; −6 ± 8 and −12 ± 10%), peak twitch (Pt; −21 ± 16 and −32 ± 17%), and paired stimuli (P100 Hz; −7 ± 11 and −12 ± 13%) were also significantly reduced after the 30-min exercise and the time trial. The first exercise was followed by a decrease in the MRCP, mainly above the mean activity measured at electrodes FC1-FC2, whereas the reduction observed after the time trial was related to the FC1-FC2 and C2 electrodes. After both exercises, the reduction in the late MRCP component above FC1-FC2 was significantly correlated with the reduction in P100 Hz (r = 0.61), and the reduction in the same component above C2 was significantly correlated with the reduction in VAL (r = 0.64). In conclusion, large-muscle group exercise induced a reduction in pre-motor potential, which was related to muscle alterations and resulted in the inability to produce a maximal voluntary contraction. PMID:27313522
Gandhi, Diksha; Crotty, Dominic J; Stevens, Grant M; Schmidt, Taly Gilat
2015-11-01
This technical note quantifies the dose and image quality performance of a clinically available organ-dose-based tube current modulation (ODM) technique, using experimental and simulation phantom studies. The investigated ODM implementation reduces the tube current for the anterior source positions, without increasing current for posterior positions, although such an approach was also evaluated for comparison. Axial CT scans at 120 kV were performed on head and chest phantoms on an ODM-equipped scanner (Optima CT660, GE Healthcare, Chalfont St. Giles, England). Dosimeters quantified dose to breast, lung, heart, spine, eye lens, and brain regions for ODM and 3D-modulation (SmartmA) settings. Monte Carlo simulations, validated with experimental data, were performed on 28 voxelized head phantoms and 10 chest phantoms to quantify organ dose and noise standard deviation. The dose and noise effects of increasing the posterior tube current were also investigated. ODM reduced the dose for all experimental dosimeters with respect to SmartmA, with average dose reductions across dosimeters of 31% (breast), 21% (lung), 24% (heart), 6% (spine), 19% (eye lens), and 11% (brain), with similar results for the simulation validation study. In the phantom library study, the average dose reduction across all phantoms was 34% (breast), 20% (lung), 8% (spine), 20% (eye lens), and 8% (brain). ODM increased the noise standard deviation in reconstructed images by 6%-20%, with generally greater noise increases in anterior regions. Increasing the posterior tube current provided similar dose reduction as ODM for breast and eye lens, increased dose to the spine, with noise effects ranging from 2% noise reduction to 16% noise increase. At noise equal to SmartmA, ODM increased the estimated effective dose by 4% and 8% for chest and head scans, respectively. Increasing the posterior tube current further increased the effective dose by 15% (chest) and 18% (head) relative to SmartmA. ODM reduced dose in all experimental and simulation studies over a range of phantoms, while increasing noise. The results suggest a net dose/noise benefit for breast and eye lens for all studied phantoms, negligible lung dose effects for two phantoms, increased lung dose and/or noise for eight phantoms, and increased dose and/or noise for brain and spine for all studied phantoms compared to the reference protocol.
van den Haak, R F F; Hamans, B C; Zuurmond, K; Verhoeven, B A N; Koning, O H J
2015-10-01
To prospectively quantify radiation dose change in aortoiliac endovascular procedures in the hybrid operating room (OR) for patients and medical staff with a novel X-ray imaging technology (ClarityIQ technology), and to assess whether procedure or fluoroscopy time or dose of iodinated contrast was affected. A prospective study including 138 patients was performed to compare radiation dose before and after installation of a novel X-ray imaging technology. Endovascular aneurysm repair (EVAR) was performed in 37 patients and an endovascular procedure for aortoiliac occlusive disease (AIOD) in 101. Patient radiation dose in air kerma (AK) and dose area product (DAP), patient demographics, and procedural data were recorded. Staff radiation dose was measured with real time personal dosimetry measurements. In both the EVAR and AIOD groups the reference system, ALX (AlluraXper FD20; Philips Healthcare, Best, the Netherlands), was compared with the upgraded X-ray system, CIQ (AlluraClarity FD20; Philips Healthcare). Procedure time, fluoroscopy time, and iodinated contrast dose were recorded. Patient radiation dose reduction in the EVAR group, in median AK, was 56% (ALX = 1,262.5 mGy; CIQ = 556.0 mGy [p < .01]); and in median DAP it was 57% (ALX = 224.4 Gycm(2) and CIQ = 95.8 Gycm(2) [p < .01]). Patient radiation dose reduction in the AIOD group, in median AK, was 76% (ALX = 1,011.0 mGy; CIQ = 248.0 mGy [p < .01]); and in median DAP it was 73% (ALX = 138.1 Gycm(2); CIQ = 38.0 Gycm(2) [p < .01]). Staff dose reduction in the EVAR group was 16% (ALX = 70.1 μSv; CIQ = 59.2 μSv [p = .43]) and in the AIOD group it was 69% (ALX = 96.2 μSv; CIQ = 30.1 μSv [p < .01]). There was no statistically significant difference between patient demographics, procedure time, fluoroscopy time, and iodinated contrast medium use in the two treatment groups before and after installation. A novel X-ray imaging technology in the hybrid OR suite resulted in a significant reduction of patient and staff radiation dose without affecting procedure length, fluoroscopy time, or use of contrast. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Greffier, Joël; Pereira, Fabricio; Macri, Francesco; Beregi, Jean-Paul; Larbi, Ahmed
2016-04-01
To evaluate the impact of Automatic Exposure Control (AEC) on radiation dose and image quality in paediatric chest scans (MDCT), with or without iterative reconstruction (IR). Three anthropomorphic phantoms representing children aged one, five and 10-year-old were explored using AEC system (CARE Dose 4D) with five modulation strength options. For each phantom, six acquisitions were carried out: one with fixed mAs (without AEC) and five each with different modulation strength. Raw data were reconstructed with Filtered Back Projection (FBP) and with two distinct levels of IR using soft and strong kernels. Dose reduction and image quality indices (Noise, SNR, CNR) were measured in lung and soft tissues. Noise Power Spectrum (NPS) was evaluated with a Catphan 600 phantom. The use of AEC produced a significant dose reduction (p<0.01) for all anthropomorphic sizes employed. According to the modulation strength applied, dose delivered was reduced from 43% to 91%. This pattern led to significantly increased noise (p<0.01) and reduced SNR and CNR (p<0.01). However, IR was able to improve these indices. The use of AEC/IR preserved image quality indices with a lower dose delivered. Doses were reduced from 39% to 58% for the one-year-old phantom, from 46% to 63% for the five-year-old phantom, and from 58% to 74% for the 10-year-old phantom. In addition, AEC/IR changed the patterns of NPS curves in amplitude and in spatial frequency. In chest paediatric MDCT, the use of AEC with IR allows one to obtain a significant dose reduction while maintaining constant image quality indices. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Heggen, Kristin Livelten; Pedersen, Hans Kristian; Andersen, Hilde Kjernlie; Martinsen, Anne Catrine T
2016-01-01
Background Iterative reconstruction can reduce image noise and thereby facilitate dose reduction. Purpose To evaluate qualitative and quantitative image quality for full dose and dose reduced head computed tomography (CT) protocols reconstructed using filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR). Material and Methods Fourteen patients undergoing follow-up head CT were included. All patients underwent full dose (FD) exam and subsequent 15% dose reduced (DR) exam, reconstructed using FBP and 30% ASIR. Qualitative image quality was assessed using visual grading characteristics. Quantitative image quality was assessed using ROI measurements in cerebrospinal fluid (CSF), white matter, peripheral and central gray matter. Additionally, quantitative image quality was measured in Catphan and vendor’s water phantom. Results There was no significant difference in qualitative image quality between FD FBP and DR ASIR. Comparing same scan FBP versus ASIR, a noise reduction of 28.6% in CSF and between −3.7 and 3.5% in brain parenchyma was observed. Comparing FD FBP versus DR ASIR, a noise reduction of 25.7% in CSF, and −7.5 and 6.3% in brain parenchyma was observed. Image contrast increased in ASIR reconstructions. Contrast-to-noise ratio was improved in DR ASIR compared to FD FBP. In phantoms, noise reduction was in the range of 3 to 28% with image content. Conclusion There was no significant difference in qualitative image quality between full dose FBP and dose reduced ASIR. CNR improved in DR ASIR compared to FD FBP mostly due to increased contrast, not reduced noise. Therefore, we recommend using caution if reducing dose and applying ASIR to maintain image quality. PMID:27583169
Østerås, Bjørn Helge; Heggen, Kristin Livelten; Pedersen, Hans Kristian; Andersen, Hilde Kjernlie; Martinsen, Anne Catrine T
2016-08-01
Iterative reconstruction can reduce image noise and thereby facilitate dose reduction. To evaluate qualitative and quantitative image quality for full dose and dose reduced head computed tomography (CT) protocols reconstructed using filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR). Fourteen patients undergoing follow-up head CT were included. All patients underwent full dose (FD) exam and subsequent 15% dose reduced (DR) exam, reconstructed using FBP and 30% ASIR. Qualitative image quality was assessed using visual grading characteristics. Quantitative image quality was assessed using ROI measurements in cerebrospinal fluid (CSF), white matter, peripheral and central gray matter. Additionally, quantitative image quality was measured in Catphan and vendor's water phantom. There was no significant difference in qualitative image quality between FD FBP and DR ASIR. Comparing same scan FBP versus ASIR, a noise reduction of 28.6% in CSF and between -3.7 and 3.5% in brain parenchyma was observed. Comparing FD FBP versus DR ASIR, a noise reduction of 25.7% in CSF, and -7.5 and 6.3% in brain parenchyma was observed. Image contrast increased in ASIR reconstructions. Contrast-to-noise ratio was improved in DR ASIR compared to FD FBP. In phantoms, noise reduction was in the range of 3 to 28% with image content. There was no significant difference in qualitative image quality between full dose FBP and dose reduced ASIR. CNR improved in DR ASIR compared to FD FBP mostly due to increased contrast, not reduced noise. Therefore, we recommend using caution if reducing dose and applying ASIR to maintain image quality.
Influence of different treatment techniques on radiation dose to the LAD coronary artery
Nieder, Carsten; Schill, Sabine; Kneschaurek, Peter; Molls, Michael
2007-01-01
Background The purpose of this proof-of-principle study was to test the ability of an intensity-modulated radiotherapy (IMRT) technique to reduce the radiation dose to the heart plus the left ventricle and a coronary artery. Radiation-induced heart disease might be a serious complication in long-term cancer survivors. Methods Planning CT scans from 6 female patients were available. They were part of a previous study of mediastinal IMRT for target volumes used in lymphoma treatment that included 8 patients and represent all cases where the left anterior descending coronary artery (LAD) could be contoured. We compared 6 MV AP/PA opposed fields to a 3D conformal 4-field technique and an optimised 7-field step-and-shoot IMRT technique and evaluated DVH's for several structures. The planning system was BrainSCAN 5.21 (BrainLAB, Heimstetten, Germany). Results IMRT maintained target volume coverage but resulted in better dose reduction to the heart, left ventricle and LAD than the other techniques. Selective dose reduction could be accomplished, although not to the degree initially attempted. The median LAD dose was approximately 50% lower with IMRT. In 5 out of 6 patients, IMRT was the best technique with regard to heart sparing. Conclusion IMRT techniques are able to reduce the radiation dose to the heart. In addition to dose reduction to whole heart, individualised dose distributions can be created, which spare, e.g., one ventricle plus one of the coronary arteries. Certain patients with well-defined vessel pathology might profit from an approach of general heart sparing with further selective dose reduction, accounting for the individual aspects of pre-existing damage. PMID:17547777
Generative Adversarial Networks for Noise Reduction in Low-Dose CT.
Wolterink, Jelmer M; Leiner, Tim; Viergever, Max A; Isgum, Ivana
2017-12-01
Noise is inherent to low-dose CT acquisition. We propose to train a convolutional neural network (CNN) jointly with an adversarial CNN to estimate routine-dose CT images from low-dose CT images and hence reduce noise. A generator CNN was trained to transform low-dose CT images into routine-dose CT images using voxelwise loss minimization. An adversarial discriminator CNN was simultaneously trained to distinguish the output of the generator from routine-dose CT images. The performance of this discriminator was used as an adversarial loss for the generator. Experiments were performed using CT images of an anthropomorphic phantom containing calcium inserts, as well as patient non-contrast-enhanced cardiac CT images. The phantom and patients were scanned at 20% and 100% routine clinical dose. Three training strategies were compared: the first used only voxelwise loss, the second combined voxelwise loss and adversarial loss, and the third used only adversarial loss. The results showed that training with only voxelwise loss resulted in the highest peak signal-to-noise ratio with respect to reference routine-dose images. However, CNNs trained with adversarial loss captured image statistics of routine-dose images better. Noise reduction improved quantification of low-density calcified inserts in phantom CT images and allowed coronary calcium scoring in low-dose patient CT images with high noise levels. Testing took less than 10 s per CT volume. CNN-based low-dose CT noise reduction in the image domain is feasible. Training with an adversarial network improves the CNNs ability to generate images with an appearance similar to that of reference routine-dose CT images.
Foley, Shane J; McEntee, Mark F; Achenbach, Stephan; Brennan, Patrick C; Rainford, Louise S; Dodd, Jonathan D
2011-08-01
The purpose of this study was to prospectively evaluate the effect of cranial breast displacement and lead shielding on in vivo breast surface radiation dose in women undergoing coronary CT angiography. Fifty-four women (mean age, 59.2 ± 9.8 years) prospectively underwent coronary 64-MDCT angiography for evaluation of chest pain. The patients were randomly assigned to a control group (n = 16), breast displacement group (n = 22), or breast displacement plus lead shielding group (n = 16). Thermoluminescent dosimeters (TLDs) were placed superficially on each breast quadrant and the areolar region of both breasts. Breast surface radiation doses, the degree of breast displacement, and coronary image quality were compared between groups. A phantom dose study was conducted to compare breast doses with z-axis positioning on the chest wall. A total of 1620 TLD dose measurements were recorded. Compared with control values, the mean breast surface dose was reduced 23% in the breast displacement group (24.3 vs 18.6 mGy, p = 0.015) and 36% in the displacement plus lead shielding group (24.3 vs 15.6 mGy, p = 0.0001). Surface dose reductions were greatest in the upper outer (displacement alone, 66%; displacement plus shielding, 63%), upper inner (65%, 58%), and areolar quadrants (44%, 53%). The smallest surface dose reductions were recorded for A-cup breasts: 7% for the displacement group and 3% for the displacement plus lead group (p = 0.741). Larger reductions in surface dose were recorded for B-cup (25% and 56%, p = 0.273), C-cup (38% and 60%, p = 0.001), and D-cup (31% and 25%, p = 0.095) sizes. Most of the patients (79%) had either good (< 50% of breast above scan range) or excellent (< 75% of breast above the scan range) breast displacement. No significant difference in coronary image quality was detected between groups. The phantom dose study showed that surface TLD measurements were underestimates of absorbed tissue dose by a mean of 9% and that a strong negative correlation exists between the amount of cranial displacement and breast dose. Use of breast displacement during coronary CTA substantially reduces the radiation dose to the breast surface.
remaining 85% of the appropriation to maximize total air pollution reduction and health benefits, improve air quality in areas disproportionately affected by air pollution, leverage additional matching funds
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simpkins, A.A.
1996-09-01
AXAOTHER XL is an Excel Spreadsheet used to determine dose to the maximally exposed offsite individual during high-velocity straight winds or tornado conditions. Both individual and population doses may be considered. Potential exposure pathways are inhalation and plume shine. For high-velocity straight winds the spreadsheet has the capability to determine the downwind relative air concentration, however for the tornado conditions, the user must enter the relative air concentration. Theoretical models are discussed and hand calculations are performed to ensure proper application of methodologies. A section has also been included that contains user instructions for the spreadsheet.
Radiation Therapy for Locally Advanced Esophageal Cancer.
Chun, Stephen G; Skinner, Heath D; Minsky, Bruce D
2017-04-01
The treatment of locally advanced esophageal cancer is controversial. For patients who are candidates for surgical resection, multiple prospective clinical trials have demonstrated the advantages of neoadjuvant chemoradiation. For patients who are medically inoperable, definitive chemoradiation is an alternative approach with survival rates comparable to trimodality therapy. Although trials of dose escalation are ongoing, the standard radiation dose remains 50.4 Gy. Modern radiotherapy techniques such as image-guided radiation therapy with motion management and intensity-modulated radiation therapy are strongly encouraged with a planning objective to maximize conformity to the intended target volume while reducing dose delivered to uninvolved normal tissues. Copyright © 2016 Elsevier Inc. All rights reserved.
1980-09-30
by radio- immunoassay after doses of high-energy electrons (1). Both cGMP and cAMP were reduced maximally 10 minutes after exposure in the cerebellum...rays, high-energy electrons , or neutrons. Using the probes diphenylhexatriene and anilinonaphthalene sulfonate, fluorescence inten- sity was reduced to...energy electrons . Alterations in the EEG patterns were observed only at radiation doses of 10 krad. No effect was obtained at 5 krad. EEG amplitude and
Dose comparison between conventional and quasi-monochromatic systems for diagnostic radiology
NASA Astrophysics Data System (ADS)
Baldelli, P.; Taibi, A.; Tuffanelli, A.; Gambaccini, M.
2004-09-01
Several techniques have been introduced in the last year to reduce the dose to the patient by minimizing the risk of tumour induced by radiation. In this work the radiological potential of dose reduction in quasi-monochromatic spectra produced via mosaic crystal Bragg diffraction has been evaluated, and a comparison with conventional spectra has been performed for four standard examinations: head, chest, abdomen and lumbar sacral spine. We have simulated quasi-monochromatic x-rays with the Shadow code, and conventional spectra with the Spectrum Processor. By means of the PCXMC software, we have simulated four examinations according to parameters established by the European Guidelines, and calculated absorbed dose for principal organs and the effective dose. Simulations of quasi-monochromatic laminar beams have been performed without anti-scatter grid, because of their inherent scatter geometry, and compared with simulations with conventional beams with anti-scatter grids. Results have shown that the dose reduction due to the introduction of quasi-monochromatic x-rays depends on different parameters related to the quality of the beam, the organ composition and the anti-scatter grid. With parameters chosen in this study a significant dose reduction can be achieved for two out of four kinds of examination.
Thomas, P; Hayton, A; Beveridge, T; Marks, P; Wallace, A
2015-09-01
To assess the influence and significance of the use of iterative reconstruction (IR) algorithms on patient dose in CT in Australia. We examined survey data submitted to the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) National Diagnostic Reference Level Service (NDRLS) during 2013 and 2014. We compared median survey dose metrics with categorization by scan region and use of IR. The use of IR results in a reduction in volume CT dose index of between 17% and 44% and a reduction in dose-length product of between 14% and 34% depending on the specific scan region. The reduction was highly significant (p < 0.001, Wilcoxon rank-sum test) for all six scan regions included in the NDRLS. Overall, 69% (806/1167) of surveys included in the analysis used IR. The use of IR in CT is achieving dose savings of 20-30% in routine practice in Australia. IR appears to be widely used by participants in the ARPANSA NDRLS with approximately 70% of surveys submitted employing this technique. This study examines the impact of the use of IR on patient dose in CT on a national scale.
Perez, Alfonso; Cao, Charlie
2017-03-01
In this phase 2, multicenter, parallel-group, double-blind, dose-ranging study, hypertensive adults (n=449) were randomized to receive one of five doses of a capsule formulation of azilsartan medoxomil (AZL-M; 5, 10, 20, 40, 80 mg), olmesartan medoxomil (OLM) 20 mg, or placebo once daily. The primary endpoint was change in trough clinic diastolic blood pressure (DBP) at week 8. AZL-M provided rapid statistically and clinically significant reductions in DBP and systolic blood pressure (SBP) vs placebo at all doses except 5 mg. Placebo-subtracted changes were greatest with the 40 mg dose (DBP, -5.7 mm Hg; SBP, -12.3 mm Hg). Clinic changes with AZL-M (all doses) were statistically indistinguishable vs OLM, although there were greater reductions with AZL-M 40 mg using 24-hour ambulatory blood pressure. Adverse event frequency was similar in the AZL-M and placebo groups. Based on these and other findings, subsequent trials investigated the commercial AZL-M tablet in the dose range of 20 to 80 mg/d. ©2016 Wiley Periodicals, Inc.
Digital radiography: optimization of image quality and dose using multi-frequency software.
Precht, H; Gerke, O; Rosendahl, K; Tingberg, A; Waaler, D
2012-09-01
New developments in processing of digital radiographs (DR), including multi-frequency processing (MFP), allow optimization of image quality and radiation dose. This is particularly promising in children as they are believed to be more sensitive to ionizing radiation than adults. To examine whether the use of MFP software reduces the radiation dose without compromising quality at DR of the femur in 5-year-old-equivalent anthropomorphic and technical phantoms. A total of 110 images of an anthropomorphic phantom were imaged on a DR system (Canon DR with CXDI-50 C detector and MLT[S] software) and analyzed by three pediatric radiologists using Visual Grading Analysis. In addition, 3,500 images taken of a technical contrast-detail phantom (CDRAD 2.0) provide an objective image-quality assessment. Optimal image-quality was maintained at a dose reduction of 61% with MLT(S) optimized images. Even for images of diagnostic quality, MLT(S) provided a dose reduction of 88% as compared to the reference image. Software impact on image quality was found significant for dose (mAs), dynamic range dark region and frequency band. By optimizing image processing parameters, a significant dose reduction is possible without significant loss of image quality.
Nishio, J. N.; Whitmarsh, J.
1993-01-01
The potency of various uncouplers for collapsing the light-induced pH gradient across thylakoid membranes in intact chloroplasts was investigated by time-resolved optical spectroscopy. The thylakoid transmembrane pH gradient ([delta]pH) was monitored indirectly by measuring the rate of cytochrome (Cyt) f reduction following a light flash of sufficient duration to create a sizable [delta]pH. The results show that the rate of Cyt f reduction is controlled in part by the internal pH of the thylakoid inner aqueous space. At pH values from 6.5 to 8.0, the Cyt f reduction rate was maximal, whereas at lower pH values from 6.5 to 5.5 the reduction rate decreased to 25% of the maximal rate. The ability of three uncouplers, nigericin, carbonylcyanide m-chlorophenylhydrazone, and gramicidin, to accelerate the rate of Cyt f reduction was determined for intact chloroplasts isolated from spinach (Spinacia oleracea). The efficacy of the uncouplers for collapsing the [delta]pH was determined using the empirical relationship between the [delta]pH and the Cyt f reduction rate. For intact chloroplasts, nigericin was the most effective uncoupler, followed by carbonylcyanide m-chlorophenylhydrazone, which interacted strongly with bovine serum albumin. Gramicidin D, even at high gramicidin:chlorophyll ratios, did not completely collapse the pH gradient, probably because it partitions in the envelope membranes and does not enter the intact chloroplast. PMID:12231669
Multi-Case Knowledge-Based IMRT Treatment Planning in Head and Neck Cancer
NASA Astrophysics Data System (ADS)
Grzetic, Shelby Mariah
Head and neck cancer (HNC) IMRT treatment planning is a challenging process that relies heavily on the planner's experience. Previously, we used the single, best match from a library of manually planned cases to semi-automatically generate IMRT plans for a new patient. The current multi-case Knowledge Based Radiation Therapy (MC-KBRT) study utilized different matching cases for each of six individual organs-at-risk (OARs), then combined those six cases to create the new treatment plan. From a database of 103 patient plans created by experienced planners, MC-KBRT plans were created for 40 (17 unilateral and 23 bilateral) HNC "query" patients. For each case, 2D beam's-eye-view images were used to find similar geometric "match" patients separately for each of 6 OARs. Dose distributions for each OAR from the 6 matching cases were combined and then warped to suit the query case's geometry. The dose-volume constraints were used to create the new query treatment plan without the need for human decision-making throughout the IMRT optimization. The optimized MC-KBRT plans were compared against the clinically approved plans and Version 1 (previous KBRT using only one matching case with dose warping) using the dose metrics: mean, median, and maximum (brainstem and cord+5mm) doses. Compared to Version 1, MC-KBRT had no significant reduction of the dose to any of the OARs in either unilateral or bilateral cases. Compared to the manually planned unilateral cases, there was significant reduction of the oral cavity mean/median dose (>2Gy) at the expense of the contralateral parotid. Compared to the manually planned bilateral cases, reduction of dose was significant in the ipsilateral parotid, larynx, and oral cavity (>3Gy mean/median) while maintaining PTV coverage. MC-KBRT planning in head and neck cancer generates IMRT plans with better dose sparing than manually created plans. MC-KBRT using multiple case matches does not show significant dose reduction compared to using a single match case with dose warping.
Proton therapy to the subdiaphragmatic region in the management of patients with Hodgkin lymphoma.
Sachsman, Suzanne; Hoppe, Bradford S; Mendenhall, Nancy P; Holtzman, Adam; Li, Zuofeng; Slayton, William; Joyce, Mike; Sandler, Eric; Flampouri, Stella
2015-07-01
Twelve consecutive patients with classical Hodgkin lymphoma (HL) involving diaphragmatic or subdiaphragmatic regions were treated on an institutional review board-approved outcomes tracking protocol. All patients underwent treatment with proton therapy following chemotherapy and had comparative three-dimensional conformal photon radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT) plans to evaluate differences in dose to organs at risk (OARs). Among the cohort, stomach doses with 3DCRT, IMRT and proton therapy were 21 Gy (median), 14 Gy and 6 Gy, respectively. Median dose reductions with proton therapy compared with 3DCRT and IMRT were 13 Gy (p = 0.0022) and 8 Gy (p = 0.0022) for the stomach. Additionally, there was significant dose reduction using proton therapy for the liver, pancreas, bowel, left kidney and right kidney. Proton therapy reduces the dose to the stomach, liver, pancreas, small bowel and kidneys compared with 3DCRT or IMRT in patients with HL requiring abdominal radiotherapy. These dose reductions are expected to translate into lower risks of secondary cancers and other late toxicities in survivors of HL.
Smith, Blake; Gelover, Edgar; Moignier, Alexandra; Wang, Dongxu; Flynn, Ryan T.; Lin, Liyong; Kirk, Maura; Solberg, Tim; Hyer, Daniel E.
2016-01-01
Purpose: To quantitatively assess the advantages of energy-layer specific dynamic collimation system (DCS) versus a per-field fixed aperture for spot scanning proton therapy (SSPT). Methods: Five brain cancer patients previously planned and treated with SSPT were replanned using an in-house treatment planning system capable of modeling collimated and uncollimated proton beamlets. The uncollimated plans, which served as a baseline for comparison, reproduced the target coverage and organ-at-risk sparing of the clinically delivered plans. The collimator opening for the fixed aperture-based plans was determined from the combined cross sections of the target in the beam’s eye view over all energy layers which included an additional margin equivalent to the maximum beamlet displacement for the respective energy of that energy layer. The DCS-based plans were created by selecting appropriate collimator positions for each row of beam spots during a Raster-style scanning pattern which were optimized to maximize the dose contributions to the target and limited the dose delivered to adjacent normal tissue. Results: The reduction of mean dose to normal tissue adjacent to the target, as defined by a 10 mm ring surrounding the target, averaged 13.65% (range: 11.8%–16.9%) and 5.18% (2.9%–7.1%) for the DCS and fixed aperture plans, respectively. The conformity index, as defined by the ratio of the volume of the 50% isodose line to the target volume, yielded an average improvement of 21.35% (19.4%–22.6%) and 8.38% (4.7%–12.0%) for the DCS and fixed aperture plans, respectively. Conclusions: The ability of the DCS to provide collimation to each energy layer yielded better conformity in comparison to fixed aperture plans. PMID:27487886
Lanning, Amelia C; Power, Geoffrey A; Christie, Anita D; Dalton, Brian H
2017-10-01
The purpose was to determine sex differences in fatigability during maximal, unconstrained velocity, shortening plantar flexions. The role of time-dependent measures (i.e., rate of torque development, rate of velocity development, and rate of neuromuscular activation) in such sex-related differences was also examined. By task termination, females exhibited smaller reductions in power and similar changes in rate of neuromuscular activation than males, indicating females were less fatigable than males.
Presne, Claire; Monge, Matthieu; Mansour, Janette; Oprisiu, Roxana; Choukroun, Gabriel; Achard, Jean Michel; Fournier, Albert
2007-10-01
Diuretics are pharmacological agents that increase natriuresis through inhibition of tubular re-absorption of sodium. The mechanisms and site of this inhibition differ with each drug class, accounting for their additive effects on natriuresis increase and their hydroelectrolytic side effects. The response to a given diuretic dose depends on the diuretic concentration on the urine at its action site. This concentration may be decreased by pharmacokinetic factors such as encountered in renal insufficiency or in nephrotic syndrome. These resistance mechanisms of diuretics may be corrected by dose increase, previous diuretic fixation on albumin or warfarin administration. Once these mechanisms are opposed, the diuretic concentration for maximal efficacy is reached at is action site and the natriuresis obtained as the normal maximal plateau. This is not the case when an oedematous systemic disease with effective hypovolemia is present, like in heart failure or cirrhosis, or when chronic use of loop diuretics has induced a hypertrophy of the more distant part of the tubule. In theses cases, a pharmacodynamic resistance exists, resulting in a lower maximal natriuresis plateau in spite of adequate concentration of the diuretic at its action site, even in the absence of pharmacokinetic resistance factors. The main indications of diuretics are systemic oedematous disease and hypertension. In the oedematous diseases, diuretics indication is both straightforward and sufficient only if effective hypervolemia is present. The therapeutic approach is discussed according to the various clinical conditions and pathophysiological background. In uncomplicated hypertension, diuretics are the cornerstone of the therapy. The most suitable diuretic treatment for hypertension is an association of low doses thiazide (12.5-50 mg/day) with potassium sparing diuretics. Rare indications of diuretics are also reviewed.
Krayenbuehl, J; Di Martino, M; Guckenberger, M; Andratschke, N
2017-10-02
Whole-brain radiation therapy (WBRT) with hippocampus sparing (HS) has been investigated by the radiation oncology working group (RTOG) 0933 trial for patients with multiple brain metastases. They showed a decrease of adverse neurocognitive effects with HS WBRT compared to WBRT alone. With the development of automated treatment planning system (aTPS) in the last years, a standardization of the plan quality at a high level was achieved. The goal of this study was to evaluate the feasibility of using an aTPS for the treatment of HS WBRT and see if the RTOG 0933 dose constraints could be achieved and improved. Ten consecutive patients treated with HS WBRT were enrolled in this study. 10 × 3 Gy was prescribed according to the RTOG 0933 protocol to 92% of the target volume (whole-brain excluding the hippocampus expanded by 5 mm in 3-dimensions). In contrast to RTOG 0933, the maximum allowed point dose to normal brain was significantly lowered and restricted to 36.5 Gy. All patients were planned with volumetric modulated arc therapy (VMAT) technique using four arcs. Plans were optimized using Auto-Planning (AP) (Philips Radiation Oncology Systems) with one single AP template and optimization. All the constraints from the RTOG 0933 trial were achieved. A significant improvement for the maximal dose to 2% of the brain with a reduction of 4 Gy was achieved (33.5 Gy vs. RTOG 37.5 Gy) and the minimum hippocampus dose was reduced by 10% (8.1 Gy vs. RTOG 9 Gy). A steep dose gradient around the hippocampus was achieved with a mean dose of 27.3 Gy at a distance between 0.5 cm and 1 cm from the hippocampus. The effective working time to optimize a plan was kept below 6'. Automated treatment planning for HS WBRT was able to fulfil all the recommendations from the RTOG 0933 study while significantly improving dose homogeneity and decreasing unnecessary hot spot in the normal brain. With this approach, a standardization of plan quality was achieved and the effective time required for plan optimization was minimized.
NASA Astrophysics Data System (ADS)
Altman, Michael B.
The increasing prevalence of intensity modulated radiation therapy (IMRT) as a treatment modality has led to a renewed interest in the potential for interaction between prolonged treatment time, as frequently associated with IMRT, and the underlying radiobiology of the irradiated tissue. A particularly relevant aspect of radiobiology is cell repair capacity, which influences cell survival, and thus directly relates to the ability to control tumors and spare normal tissues. For a single fraction of radiation, the linear quadratic (LQ) model is commonly used to relate the radiation dose to the fraction of cells surviving. The LQ model implies a dependence on two time-related factors which correlate to radiobiological effects: the duration of radiation application, and the functional form of how the dose is applied over that time (the "temporal pattern of applied dose"). Although the former has been well studied, the latter has not. Thus, the goal of this research is to investigate the impact of the temporal pattern of applied dose on the survival of human cells and to explore how the manipulation of this temporal dose pattern may be incorporated into an IMRT-based radiation therapy treatment planning scheme. The hypothesis is that the temporal pattern of applied dose in a single fraction of radiation can be optimized to maximize or minimize cell kill. Furthermore, techniques which utilize this effect could have clinical ramifications. In situations where increased cell kill is desirable, such as tumor control, or limiting the degree of cell kill is important, such as the sparing of normal tissue, temporal sequences of dose which maximize or minimize cell kill (temporally "optimized" sequences) may provide greater benefit than current clinically used radiation patterns. In the first part of this work, an LQ-based modeling analysis of effects of the temporal pattern of dose on cell kill is performed. Through this, patterns are identified for maximizing cell kill for a given radiation pattern by concentrating the highest doses in the middle of a fraction (a "Triangle" pattern), or minimizing cell kill by placing the highest doses near the beginning and end (a "V-shaped" pattern). The conditions under which temporal optimization effects are most acute are also identified: irradiation of low alpha/beta tissues, long fraction durations, and high doses/fx. An in vitro study is then performed which verifies that the temporal effects and trends predicted by the modeling study are clearly manifested in human cells. Following this a phantom which could allow similar in vitro radiobiological experiments in a 3-dimensional clinically-based environment is designed, created, and dosimetrically assessed using TLDs, film, and biological assay-based techniques. The phantom is found to be a useful and versatile tool for such experiments. A scheme for utilizing the phantom in a clinical treatment environment is then developed. This includes a demonstration of prototype methods for optimizing the temporal pattern of applied dose in clinical IMRT plans to manipulate tissue-dependent effects. Looking toward future experimental validation of such plans using the phantom, an analysis of the suitability of biological assays for use in phantom-based in vitro experiments is performed. Finally, a discussion is provided about the steps necessary to integrate temporal optimization into in vivo experiments and ultimately into a clinical radiation therapy environment. If temporal optimization is ultimately shown to have impact in vivo, the successful implementation of the methods developed in this study could enhance the efficacy and care of thousands of patients receiving radiotherapy.
Greer, Joseph A.; Pirl, William F.; Park, Elyse R.; Lynch, Thomas J.; Temel, Jennifer S.
2013-01-01
Objective Dose delays and reductions in chemotherapy due to hematologic toxicities are common among patients with advanced non-small-cell lung cancer (NSCLC). However, limited data exist on behavioral or psychological predictors of chemotherapy adherence. The goal of this study was to explore the frequency and clinical predictors of infusion dose delays and reductions in this patient population. Methods Fifty patients newly diagnosed with advanced NSCLC of high performance status (ECOG PS=0-1) completed baseline assessments on quality of life (FACT-L) and mood (HADS) within eight weeks of diagnosis. Participants were followed prospectively for six months. Chemotherapy dosing data came from medical chart review. Results All patients received chemotherapy during the course of the study, beginning with either a platinum-based doublet (74%), an oral epidermal growth factor receptor-tyrosine kinase inhibitor (14%), or a parenteral single agent (12%). Forty percent (N=20) of patients had either a dose delay (38%) and/or reduction (16%) in their scheduled infusions. Fisher’s exact tests showed that patients who experienced neutropenia, smoked at the time of diagnosis, or reported heightened baseline anxiety were significantly more likely to experience dose delays or reductions. There were no associations between chemotherapy adherence and patient demographics, performance status, or quality of life. Conclusion In this sample, over one-third of patients with advanced NSCLC experienced either a dose delay or reduction in prescribed chemotherapy regimens. Behavioral and psychological factors, such as tobacco use and anxiety symptoms, appear to play an important role in chemotherapy adherence, though further study is required to confirm these findings. PMID:19027443
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khan, S; Chin, E; Xing, L
Purpose: The integration of couch motion during arc delivery is necessitated to enable irradiation trajectories such as coronal arcs, and to enhance the geometrical sampling for dynamic deliveries to the highest extent. To enable such capability, a platform of Trajectory Modulated Arc Therapy (TMAT) is developed in conjunction with standardized noncollisional dynamic path-set for irradiation of intracranial lesions. Methods: A generalized path-set was constructed through the combination of sagittal arcs (45 degrees from the CAX), axial arcs, and coronal arcs produced through modulation of the dynamic rotation of couch. The standardized path was implemented in a contiguous manner enabling themore » formation of fully automated sub-trajectories to provide maximal geometrical convergence with minimal number of arcs. Progressive sampling technique is used for direct aperture optimization of the MLCs and the selection of couch positions across the control points. Dosimetry of the resulting plans was assessed relative to clinically delivered plans. Using the TrueBeam Developer Mode, plan deliverability was tested. Results: Treatment planning of TMAT sub-trajectories for central, anterior and posterior tumor sites with volumes ranging from 4.75cc to 107cc demonstrated radically reduced doses to the critical OARs when compared to the clinically treated VMAT. Specifically, percentage reduction in mean dose for critical organs such as brainstem, cochlea, and optic nerve are found to be as low as 74±15%, 50±26% and 74±30% respectively as compared to VMAT. Conformity Index, defined as the ratio of tumor volume (VPTV) and 100% dose volume (V(D100%)), was reduced up to 12% while the Gradient Index, defined as V(D100%)/V(D50%), was concurrently improved by up to 14%. Conclusion: An automated standardized trajectory with dynamically modulated couch-gantry arcs has been developed for intracranial radiotherapy. Through the incorporation of coronal arcs, it is demonstrated that significantly reduced OAR doses can be achieved relative to clinically treated patient plans via VMAT. Research Grant Funding Support by Varian Medical Systems.« less
Freise, Kevin J; Shebley, Mohamad; Salem, Ahmed Hamed
2017-06-01
The objectives of the analysis were to develop and verify a venetoclax physiologically based pharmacokinetic (PBPK) model to predict the effects of cytochrome P450 3A (CYP3A) inhibitors and inducers on the PK of venetoclax and inform dosing recommendations. A minimal PBPK model was developed based on prior in vitro and in vivo clinical data using a "middle-out" approach. The PBPK model was independently verified against clinical studies of the strong CYP3A inhibitor ketoconazole, the strong CYP3A inducer, multiple-dose rifampin, and the steady-state venetoclax PK in chronic lymphocytic leukemia (CLL) subjects by comparing predicted to observed ratios of the venetoclax maximum concentration (C max R) and area under the curve from time 0 to infinity (AUC ∞ R) from these studies. The verified PBPK model was then used to simulate the effects of different CYP3A inhibitors and inducers on the venetoclax PK. Comparison of the PBPK model predicted to the observed PK parameters indicated good agreement. Verification of the PBPK model demonstrated that the ratios of the predicted:observed C max R and AUC ∞ R of venetoclax were within 0.8- to 1.25-fold range for strong CYP3A inhibitors and inducers. Model simulations indicated no effect of weak CYP3A inhibitors or inducers on C max or AUC ∞ , while both moderate and strong CYP3A inducers were estimated to decrease venetoclax exposure. Moderate and strong CYP3A inhibitors were estimated to increase venetoclax AUC ∞ , by 100% to 390% and 480% to 680%, respectively. The recommended venetoclax dose reductions of at least 50% and 75% when coadministered with moderate and strong CYP3A inhibitors, respectively, maintain venetoclax exposures between therapeutic and maximally administered safe doses. © 2017, The American College of Clinical Pharmacology.
Approaches to reducing photon dose calculation errors near metal implants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Jessie Y.; Followill, David S.; Howell, Reb
Purpose: Dose calculation errors near metal implants are caused by limitations of the dose calculation algorithm in modeling tissue/metal interface effects as well as density assignment errors caused by imaging artifacts. The purpose of this study was to investigate two strategies for reducing dose calculation errors near metal implants: implementation of metal-based energy deposition kernels in the convolution/superposition (C/S) dose calculation method and use of metal artifact reduction methods for computed tomography (CT) imaging. Methods: Both error reduction strategies were investigated using a simple geometric slab phantom with a rectangular metal insert (composed of titanium or Cerrobend), as well asmore » two anthropomorphic phantoms (one with spinal hardware and one with dental fillings), designed to mimic relevant clinical scenarios. To assess the dosimetric impact of metal kernels, the authors implemented titanium and silver kernels in a commercial collapsed cone C/S algorithm. To assess the impact of CT metal artifact reduction methods, the authors performed dose calculations using baseline imaging techniques (uncorrected 120 kVp imaging) and three commercial metal artifact reduction methods: Philips Healthcare’s O-MAR, GE Healthcare’s monochromatic gemstone spectral imaging (GSI) using dual-energy CT, and GSI with metal artifact reduction software (MARS) applied. For the simple geometric phantom, radiochromic film was used to measure dose upstream and downstream of metal inserts. For the anthropomorphic phantoms, ion chambers and radiochromic film were used to quantify the benefit of the error reduction strategies. Results: Metal kernels did not universally improve accuracy but rather resulted in better accuracy upstream of metal implants and decreased accuracy directly downstream. For the clinical cases (spinal hardware and dental fillings), metal kernels had very little impact on the dose calculation accuracy (<1.0%). Of the commercial CT artifact reduction methods investigated, the authors found that O-MAR was the most consistent method, resulting in either improved dose calculation accuracy (dental case) or little impact on calculation accuracy (spine case). GSI was unsuccessful at reducing the severe artifacts caused by dental fillings and had very little impact on calculation accuracy. GSI with MARS on the other hand gave mixed results, sometimes introducing metal distortion and increasing calculation errors (titanium rectangular implant and titanium spinal hardware) but other times very successfully reducing artifacts (Cerrobend rectangular implant and dental fillings). Conclusions: Though successful at improving dose calculation accuracy upstream of metal implants, metal kernels were not found to substantially improve accuracy for clinical cases. Of the commercial artifact reduction methods investigated, O-MAR was found to be the most consistent candidate for all-purpose CT simulation imaging. The MARS algorithm for GSI should be used with caution for titanium implants, larger implants, and implants located near heterogeneities as it can distort the size and shape of implants and increase calculation errors.« less
Matsuda, Norihiro; Mikami, Satoshi; Sato, Tetsuro; Saito, Kimiaki
2017-01-01
Measurements of air dose rates for 192 houses in a less contaminated area (<0.5 μSv h -1 ) of the Fukushima Prefecture in Japan were conducted in both living rooms and/or bedrooms using optically stimulated luminescence (OSL) dosimeters and around the houses via a man-borne survey at intervals of several meters. The relation of the two air dose rates (inside and outside) for each house, including the background from natural radionuclides, was divided into several categories, determined by construction materials (light and heavy) and floor number, with the dose reduction factors being expressed as the ratio of the dose inside to that outside the house. For wooden and lightweight steel houses (classed as light), the dose rates inside and outside the houses showed a positive correlation and linear regression with a slope-intercept form due to the natural background, although the degree of correlation was not very high. The regression coefficient, i.e., the average dose reduction factor, was 0.38 on the first floor and 0.49 on the second floor. It was found that the contribution of natural radiation cannot be neglected when we consider dose reduction factors in less contaminated areas. The reductions in indoor dose rates are observed because a patch of ground under each house is not contaminated (this is the so-called uncontaminated effect) since the shielding capability of light construction materials is typically low. For reinforced steel-framed concrete houses (classed as heavy), the dose rates inside the houses did not show a correlation with those outside the houses due to the substantial shielding capability of these materials. The average indoor dose rates were slightly higher than the arithmetic mean value of the outdoor dose rates from the natural background because concrete acts as a source of natural radionuclides. The characteristics of the uncontaminated effect were clarified through Monte Carlo simulations. It was found that there is a great variation in air dose rates even within one house, depending on the height of the area and its closeness to the outside boundary. Measurements of outdoor dose rates required consideration of local variations depending on the environment surrounding each house. The representative value was obtained from detailed distributions of air dose rates around the house, as measured by a man-borne survey. Therefore, it is imperative to recognize that dose reduction factors fluctuate in response to various factors such as the size and shape of a house, construction materials acting as a shield and as sources, position (including height) within a room, floor number, total number of floors, and surrounding environment. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Schäfer, M-L; Lüdemann, L; Böning, G; Kahn, J; Fuchs, S; Hamm, B; Streitparth, F
2016-05-01
To compare the radiation dose and image quality of 64-row chest computed tomography (CT) in patients with bronchial carcinoma or intrapulmonary metastases using full-dose CT reconstructed with filtered back projection (FBP) at baseline and reduced dose with 40% adaptive statistical iterative reconstruction (ASIR) at follow-up. The chest CT images of patients who underwent FBP and ASIR studies were reviewed. Dose-length products (DLP), effective dose, and size-specific dose estimates (SSDEs) were obtained. Image quality was analysed quantitatively by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurement. In addition, image quality was assessed by two blinded radiologists evaluating images for noise, contrast, artefacts, visibility of small structures, and diagnostic acceptability using a five-point scale. The ASIR studies showed 36% reduction in effective dose compared with the FBP studies. The qualitative and quantitative image quality was good to excellent in both protocols, without significant differences. There were also no significant differences for SNR except for the SNR of lung surrounding the tumour (FBP: 35±17, ASIR: 39±22). A protocol with 40% ASIR can provide approximately 36% dose reduction in chest CT of patients with bronchial carcinoma or intrapulmonary metastases while maintaining excellent image quality. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Widmann, G; Dalla Torre, D; Hoermann, R; Schullian, P; Gassner, E M; Bale, R; Puelacher, W
2015-04-01
The influence of dose reductions on diagnostic quality using a series of high-resolution ultralow-dose computed tomography (CT) scans for computer-assisted planning and surgery including the most recent iterative reconstruction algorithms was evaluated and compared with the fracture detectability of a standard cranial emergency protocol. A human cadaver head including the mandible was artificially prepared with midfacial and orbital fractures and scanned using a 64-multislice CT scanner. The CT dose index volume (CTDIvol) and effective doses were calculated using application software. Noise was evaluated as the standard deviation in Hounsfield units within an identical region of interest in the posterior fossa. Diagnostic quality was assessed by consensus reading of a craniomaxillofacial surgeon and radiologist. Compared with the emergency protocol at CTDIvol 35.3 mGy and effective dose 3.6 mSv, low-dose protocols down to CTDIvol 1.0 mGy and 0.1 mSv (97% dose reduction) may be sufficient for the diagnosis of dislocated craniofacial fractures. Non-dislocated fractures may be detected at CTDIvol 2.6 mGy and 0.3 mSv (93% dose reduction). Adaptive statistical iterative reconstruction (ASIR) 50 and 100 reduced average noise by 30% and 56%, and model-based iterative reconstruction (MBIR) by 93%. However, the detection rate of fractures could not be improved due to smoothing effects. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.
Li, Zhi; Yang, Rong-Tao; Li, Zu-Bing
2015-09-01
Computer-assisted navigation has been widely used in oral and maxillofacial surgery. The purpose of this study was to describe the applications of computer-assisted navigation for the minimally invasive reduction of isolated zygomatic arch fractures. All patients identified as having isolated zygomatic arch fractures presenting to the authors' department from April 2013 through November 2014 were included in this prospective study. Minimally invasive reductions of isolated zygomatic arch fractures were performed on these patients under the guidance of computer-assisted navigation. The reduction status was evaluated by postoperative computed tomography (CT) 1 week after the operation. Postoperative complications and facial contours were evaluated during follow-up. Functional recovery was evaluated by the difference between the preoperative maximum interincisal mouth opening and that at the final follow-up. Twenty-three patients were included in this case series. The operation proceeded well in all patients. Postoperatively, all patients displayed uneventful healing without postoperative complication. Postoperative CT showed exact reduction in all cases. Satisfactory facial contour and functional recovery were observed in all patients. The preoperative maximal mouth opening ranged from 8 to 25 mm, and the maximal mouth opening at the final follow-up ranged from 36 to 42 mm. Computer-assisted navigation can be used not only for guiding zygomatic arch fracture reduction, but also for assessing reduction. Computer-assisted navigation is an effective and minimally invasive technique that can be applied in the reduction of isolated zygomatic arch fractures. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ben-David, Merav A.; Diamante, Maximiliano; Radawski, Jeffrey D.
Purpose: To assess the prevalence and dosimetric and clinical predictors of mandibular osteoradionecrosis (ORN) in patients with head and neck cancer who underwent a pretherapy dental evaluation and prophylactic treatment according to a uniform policy and were treated with intensity-modulated radiotherapy (IMRT). Methods and Materials: Between 1996 and 2005, all patients with head-and-neck cancer treated with parotid gland-sparing IMRT in prospective studies underwent a dental examination and prophylactic treatment according to a uniform policy that included extractions of high-risk, periodontally involved, and nonrestorable teeth in parts of the mandible expected to receive high radiation doses, fluoride supplements, and the placementmore » of guards aiming to reduce electron backscatter off metal teeth restorations. The IMRT plans included dose constraints for the maximal mandibular doses and reduced mean parotid gland and noninvolved oral cavity doses. A retrospective analysis of Grade 2 or worse (clinical) ORN was performed. Results: A total of 176 patients had a minimal follow-up of 6 months. Of these, 31 (17%) had undergone teeth extractions before RT and 13 (7%) after RT. Of the 176 patients, 75% and 50% had received {>=}65 Gy and {>=}70 Gy to {>=}1% of the mandibular volume, respectively. Falloff across the mandible characterized the dose distributions: the average gradient (in the axial plane containing the maximal mandibular dose) was 11 Gy (range, 1-27 Gy; median, 8 Gy). At a median follow-up of 34 months, no cases of ORN had developed (95% confidence interval, 0-2%). Conclusion: The use of a strict prophylactic dental care policy and IMRT resulted in no case of clinical ORN. In addition to the dosimetric advantages offered by IMRT, meticulous dental prophylactic care is likely an essential factor in reducing ORN risk.« less
Arrossi, Silvina; Temin, Sarah; Garland, Suzanne; Eckert, Linda O'Neal; Bhatla, Neerja; Castellsagué, Xavier; Alkaff, Sharifa Ezat; Felder, Tamika; Hammouda, Doudja; Konno, Ryo; Lopes, Gilberto; Mugisha, Emmanuel; Murillo, Rául; Scarinci, Isabel C; Stanley, Margaret; Tsu, Vivien; Wheeler, Cosette M; Adewole, Isaac Folorunso; de Sanjosé, Silvia
2017-10-01
To provide resource-stratified (four tiers), evidence-based recommendations on the primary prevention of cervical cancer globally. The American Society of Clinical Oncology convened a multidisciplinary, multinational panel of oncology, obstetrics/gynecology, public health, cancer control, epidemiology/biostatistics, health economics, behavioral/implementation science, and patient advocacy experts. The Expert Panel reviewed existing guidelines and conducted a modified ADAPTE process and a formal consensus-based process with additional experts (consensus ratings group) for one round of formal ratings. Existing sets of guidelines from five guideline developers were identified and reviewed; adapted recommendations formed the evidence base. Five systematic reviews, along with cost-effectiveness analyses, provided evidence to inform the formal consensus process, which resulted in agreement of ≥ 75%. In all resource settings, two doses of human papillomavirus vaccine are recommended for girls age 9 to 14 years, with an interval of at least 6 months and possibly up to 12 to 15 months. Individuals with HIV positivity should receive three doses. Maximal and enhanced settings: if girls are age ≥ 15 years and received their first dose before age 15 years, they may complete the series; if no doses were received before age 15 years, three doses should be administered; in both scenarios, vaccination may be through age 26 years. Limited and basic settings: if sufficient resources remain after vaccinating girls age 9 to 14 years, girls who received one dose may receive additional doses between age 15 and 26 years. Maximal, enhanced, and limited settings: if ≥ 50% coverage in the priority female target population, sufficient resources, and cost effectiveness, boys may be vaccinated to prevent other noncervical human papillomavirus-related cancers and diseases. Basic settings: vaccinating boys is not recommended. It is the view of the American Society of Clinical Oncology that health care providers and health care system decision makers should be guided by the recommendations for the highest stratum of resources available. The guideline is intended to complement but not replace local guidelines.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rodrigues, George, E-mail: george.rodrigues@lhsc.on.ca; Yartsev, Slav; Yaremko, Brian
2011-07-15
Purpose: Stereotactic radiosurgery is an alternative to surgical resection for selected intracranial lesions. Integrated image-guided intensity-modulated-capable radiotherapy platforms such as helical tomotherapy (HT) could potentially replace traditional radiosurgery apparatus. The present study's objective was to determine the maximally tolerated dose of a simultaneous in-field boost integrated with whole brain radiotherapy for palliative treatment of patients with one to three brain metastases using HT. Methods and Materials: The inclusion/exclusion criteria and endpoints were consistent with the Radiation Therapy Oncology Group 9508 radiosurgery trial. The cohorts were constructed with a 3 + 3 design; however, additional patients were enrolled in the lowermore » dose tolerable cohorts during the toxicity assessment periods. Whole brain radiotherapy (30 Gy in 10 fractions) was delivered with a 5-30-Gy (total lesion dose of 35-60 Gy in 10 fractions) simultaneous in-field boost delivered to the brain metastases. The maximally tolerated dose was determined by the frequency of neurologic Grade 3-5 National Cancer Institute Common Toxicity Criteria, version 3.0, dose-limiting toxicity events within each Phase I cohort. Results: A total of 48 patients received treatment in the 35-Gy (n = 3), 40-Gy (n = 16), 50-Gy (n = 15), 55-Gy (n = 8), and 60-Gy (n = 6) cohorts. No patients experienced dose-limiting toxicity events in any of the trial cohorts. The 3-month RECIST assessments available for 32 of the 48 patients demonstrated a complete response in 2, a partial response in 16, stable disease in 6, and progressive disease in 8 patients. Conclusion: The delivery of 60 Gy in 10 fractions to one to three brain metastases synchronously with 30 Gy whole brain radiotherapy was achieved without dose-limiting central nervous system toxicity as assessed 3 months after treatment. This approach is being tested in a Phase II efficacy trial.« less
Tse, Karen; Sillito, Rowland; Keerie, Amy; Collier, Rachel; Grant, Claire; Karp, Natasha A; Vickers, Cathy; Chapman, Kathryn; Armstrong, J Douglas; Redfern, William S
2018-04-01
The ActualHCA™ system continuously monitors the activity, temperature and behavior of group-housed rats without invasive surgery. The system was validated to detect the contrasting effects of sedative and stimulant test agents (chlorpromazine, clonidine and amphetamine), and compared with the modified Irwin test (mIT) with rectal temperature measurements. Six male Han Wistar rats per group were used to assess each test agent and vehicle controls in separate ActualHCA™ recordings and mIT. The mIT was undertaken at 15, 30 mins, 1, 2, 4 and 24 h post-dose. ActualHCA™ recorded continuously for 24 h post-dose under 3 experimental conditions: dosed during light phase, dark phase, and light phase with a scheduled cage change at the time of peak effects determined by mIT. ActualHCA™ detected an increase stimulated activity from the cage change at 1-2 h post-dose which was obliterated by chlorpromazine and clonidine. Amphetamine increased activity up to 4 h post-dose in all conditions. Temperature from ActualHCA™ was affected by all test agents in all conditions. The mIT showed effects on all 3 test agents up to 4 h post-dose, with maximal effects at 1-2 h post-dose. The maximal effects on temperature from ActualHCA™ differed from mIT. Delayed effects on activity were detected by ActualHCA™, but not on mIT. Continuous monitoring has the advantage of capturing effects over time that may be missed with manual tests using pre-determined time points. This automated behavioural system does not replace the need for conventional methods but could be implemented simultaneously to improve our understanding of behavioural pharmacology. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Clohisy, J. C.; Connolly, T. J.; Bergman, K. D.; Quinn, C. O.; Partridge, N. C.
1994-01-01
Individual prostanoids have distinct potencies in activating intracellular signaling pathways and regulating gene expression in osteoblastic cells. The E-series prostaglandins (PGs) are known to stimulate matrix metalloproteinase-1 (MMP-1) synthesis and secretion in certain rodent and human osteoblastic cells, yet the intracellular events involved remain unclear. To further characterize this response and its signal transduction pathway(s), we examined prostanoid-induced expression of the MMP-1 gene in the rat osteoblastic osteosarcoma cell line UMR 106-01. Northern blot analysis demonstrated that prostaglandin E2 (PGE2) and PGE1 were very potent stimulators (40-fold) of MMP-1 transcript abundance, PGF2 alpha and prostacyclin were weak stimulators (4-fold), and thromboxane-B2 had no effect. The marked increase in MMP-1 transcript abundance after PGE2 treatment was first detected at 2 h, became maximal at 4 h, and persisted beyond 24 h. This response was dose dependent and elicited maximal and half-maximal effects with concentrations of 10(-6) and 0.6 x 10(-7) M, respectively. Cycloheximide, a protein synthesis inhibitor, completely blocked this effect of PGE2, suggesting that the expression of other genes is required. Nuclear run-on experiments demonstrated that PGE2 rapidly activates MMP-1 gene transcription, with a maximal increase at 2-4 h. The second messenger analog, 8-bromo-cAMP, mimicked the effects of PGE2 by stimulating a dose-dependent increase in MMP-1 messenger RNA (mRNA) levels, with a maximal effect quantitatively similar to that observed with PGE2. Thus, in UMR 106-01 cells, different prostanoids have distinct potencies in stimulating MMP-1 mRNA abundance. Our data suggest that PGE2 stimulation of MMP-1 synthesis is due to activation of MMP-1 gene transcription and a subsequent marked increase in MMP-1 mRNA abundance. This effect is dependent on de novo protein synthesis and is mimicked by protein kinase-A activation.
Guillemette, G; Favreau, I; Lamontagne, S; Boulay, G
1990-04-25
Inositol 1,4,5-trisphosphate (InsP3) is an important second messenger generated from the hydrolysis of phosphatidylinositol 4,5-bisphosphate by phospholipase C in response to Ca2(+)-mobilizing stimuli. InsP3 interacts with specific intracellular receptors and triggers the release of sequestered Ca2+ from an intracellular store. We have looked at the influence of 2,3-diphosphoglycerate on the action and metabolism of InsP3 in the bovine adrenal cortex. 2,3-Diphosphoglycerate blocked InsP3 binding to adrenal cortex microsomes with a half-maximal efficiency of 0.5 mM. Scatchard analyses revealed that 2,3-diphosphoglycerate did not change the maximal capacity of the microsomes, but decreased their binding affinity for InsP3. The Ca2(+)-releasing activity of InsP3 on the same microsomal preparation was monitored with the fluorescent indicator, Fura-2. 2,3-Diphosphoglycerate blocked this activity with a half-maximal efficiency of 2 mM. The effect of 2,3-diphosphoglycerate could be overcome by supramaximal doses of InsP3, indicating a competitive inhibitory effect. The activity of InsP3 phosphatase from bovine adrenal cortex microsomes was also studied. 2,3-Diphosphoglycerate inhibited the activity of the phosphatase with a half-maximal efficiency of 0.3 mM. Lineweaver-Burke plots revealed that this effect was competitive. Finally, 2,3-diphosphoglycerate was also able to inhibit the activity of a partially purified preparation of InsP3 kinase from bovine adrenal cortex cytosol. The half-maximal dose was around 10 mM and the Lineweaver-Burke plot showed that the inhibition was competitive. These results show that 2,3-diphosphoglycerate can be considered as a structural analog of InsP3. Its inhibitory effects, however, are not selective enough to use it as an InsP3 protective agent in Ca2(+)-mobilization studies.
Effects of long term supplementation of anabolic androgen steroids on human skeletal muscle.
Yu, Ji-Guo; Bonnerud, Patrik; Eriksson, Anders; Stål, Per S; Tegner, Yelverton; Malm, Christer
2014-01-01
The effects of long-term (over several years) anabolic androgen steroids (AAS) administration on human skeletal muscle are still unclear. In this study, seventeen strength training athletes were recruited and individually interviewed regarding self-administration of banned substances. Ten subjects admitted having taken AAS or AAS derivatives for the past 5 to 15 years (Doped) and the dosage and type of banned substances were recorded. The remaining seven subjects testified to having never used any banned substances (Clean). For all subjects, maximal muscle strength and body composition were tested, and biopsies from the vastus lateralis muscle were obtained. Using histochemistry and immunohistochemistry (IHC), muscle biopsies were evaluated for morphology including fiber type composition, fiber size, capillary variables and myonuclei. Compared with the Clean athletes, the Doped athletes had significantly higher lean leg mass, capillary per fibre and myonuclei per fiber. In contrast, the Doped athletes had significantly lower absolute value in maximal squat force and relative values in maximal squat force (relative to lean body mass, to lean leg mass and to muscle fiber area). Using multivariate statistics, an orthogonal projection of latent structure discriminant analysis (OPLS-DA) model was established, in which the maximal squat force relative to muscle mass and the maximal squat force relative to fiber area, together with capillary density and nuclei density were the most important variables for separating Doped from the Clean athletes (regression = 0.93 and prediction = 0.92, p<0.0001). In Doped athletes, AAS dose-dependent increases were observed in lean body mass, muscle fiber area, capillary density and myonuclei density. In conclusion, long term AAS supplementation led to increases in lean leg mass, muscle fiber size and a parallel improvement in muscle strength, and all were dose-dependent. Administration of AAS may induce sustained morphological changes in human skeletal muscle, leading to physical performance enhancement.
Effects of Long Term Supplementation of Anabolic Androgen Steroids on Human Skeletal Muscle
Yu, Ji-Guo; Bonnerud, Patrik; Eriksson, Anders; Stål, Per S.; Tegner, Yelverton; Malm, Christer
2014-01-01
The effects of long-term (over several years) anabolic androgen steroids (AAS) administration on human skeletal muscle are still unclear. In this study, seventeen strength training athletes were recruited and individually interviewed regarding self-administration of banned substances. Ten subjects admitted having taken AAS or AAS derivatives for the past 5 to 15 years (Doped) and the dosage and type of banned substances were recorded. The remaining seven subjects testified to having never used any banned substances (Clean). For all subjects, maximal muscle strength and body composition were tested, and biopsies from the vastus lateralis muscle were obtained. Using histochemistry and immunohistochemistry (IHC), muscle biopsies were evaluated for morphology including fiber type composition, fiber size, capillary variables and myonuclei. Compared with the Clean athletes, the Doped athletes had significantly higher lean leg mass, capillary per fibre and myonuclei per fiber. In contrast, the Doped athletes had significantly lower absolute value in maximal squat force and relative values in maximal squat force (relative to lean body mass, to lean leg mass and to muscle fiber area). Using multivariate statistics, an orthogonal projection of latent structure discriminant analysis (OPLS-DA) model was established, in which the maximal squat force relative to muscle mass and the maximal squat force relative to fiber area, together with capillary density and nuclei density were the most important variables for separating Doped from the Clean athletes (regression = 0.93 and prediction = 0.92, p<0.0001). In Doped athletes, AAS dose-dependent increases were observed in lean body mass, muscle fiber area, capillary density and myonuclei density. In conclusion, long term AAS supplementation led to increases in lean leg mass, muscle fiber size and a parallel improvement in muscle strength, and all were dose-dependent. Administration of AAS may induce sustained morphological changes in human skeletal muscle, leading to physical performance enhancement. PMID:25207812
Reinforcing effects of sigma-receptor agonists in rats trained to self-administer cocaine.
Hiranita, Takato; Soto, Paul L; Tanda, Gianluigi; Katz, Jonathan L
2010-02-01
sigma-Receptor (sigmaR) antagonists have been reported to block certain effects of psychostimulant drugs. The present study examined the effects of sigmaR ligands in rats trained to self-administer cocaine (0.032-1.0 mg/kg/inj i.v.) under fixed-ratio 5-response schedules of reinforcement. Maximal rates of responding were maintained by 0.32 mg/kg/inj cocaine, or by the sigmaR agonists, 1,3-di-(2-tolyl)guanidine (DTG; 1.0 mg/kg/inj) or 2-(4-morpholinethyl) 1-phenylcyclohexane-1-carboxylate hydrochloride (PRE-084; 0.32 mg/kg/inj), when substituted for cocaine. Lower response rates were maintained at higher and lower doses of the compounds. No dose of the sigmaR antagonists [N-[2-(3,4-dichlorophenyl)ethyl]-N-methyl-2-(1-pyrrolidinyl)ethylamine (BD 1008), N-[2-(3,4-dichlorophenyl)ethyl]-N-methyl-2-(dimethylamino)ethylamine (BD 1047), N-[2-(3,4-dichlorophenyl)ethyl]-4-methylpiperazine (BD 1063)] maintained responding appreciably above levels obtained when responding had no consequences. Presession treatment with sigmaR agonists dose-dependently shifted the cocaine self-administration dose-effect curve leftward. The dopamine-uptake inhibitor, (-)-2beta-carbomethoxy-3beta-(4-fluorophenyl)tropane (WIN 35,428), dose-dependently shifted the DTG and PRE-084 self-administration dose-effect curves leftward. Treatment with the sigmaR antagonists dose-dependently decreased response rates maintained by DTG or PRE-084, but did not affect cocaine self-administration. Response rates maintained by maximally effective DTG or PRE-084 doses were decreased by sigmaR antagonists at lower doses than those that decreased response rates maintained by food reinforcement. Although sigmaR antagonists block some cocaine-induced effects, the lack of effect on cocaine self-administration suggests that the primary reinforcing effects of cocaine do not involve direct effects at sigmaRs. However, the self-administration of sigmaR agonists in cocaine-trained subjects, facilitation of cocaine self-administration by sigmaR-agonist pretreatment, and the facilitation of sigmaR-agonist self-administration by WIN 35,428, together suggest enhanced abuse-related effects resulting from concomitant dopaminergically mediated actions and sigmaR-mediated actions of the drugs.
Reinforcing Effects of σ-Receptor Agonists in Rats Trained to Self-Administer Cocaine
Hiranita, Takato; Soto, Paul L.; Tanda, Gianluigi
2010-01-01
σ-Receptor (σR) antagonists have been reported to block certain effects of psychostimulant drugs. The present study examined the effects of σR ligands in rats trained to self-administer cocaine (0.032–1.0 mg/kg/inj i.v.) under fixed-ratio 5-response schedules of reinforcement. Maximal rates of responding were maintained by 0.32 mg/kg/inj cocaine, or by the σR agonists, 1,3-di-(2-tolyl)guanidine (DTG; 1.0 mg/kg/inj) or 2-(4-morpholinethyl) 1-phenylcyclohexane-1-carboxylate hydrochloride (PRE-084; 0.32 mg/kg/inj), when substituted for cocaine. Lower response rates were maintained at higher and lower doses of the compounds. No dose of the σR antagonists [N-[2-(3,4-dichlorophenyl)ethyl]-N-methyl-2-(1-pyrrolidinyl)ethylamine (BD 1008), N-[2-(3,4-dichlorophenyl)ethyl]-N-methyl-2-(dimethylamino)ethylamine (BD 1047), N-[2-(3,4-dichlorophenyl)ethyl]-4-methylpiperazine (BD 1063)] maintained responding appreciably above levels obtained when responding had no consequences. Presession treatment with σR agonists dose-dependently shifted the cocaine self-administration dose-effect curve leftward. The dopamine-uptake inhibitor, (−)-2β-carbomethoxy-3β-(4-fluorophenyl)tropane (WIN 35,428), dose-dependently shifted the DTG and PRE-084 self-administration dose-effect curves leftward. Treatment with the σR antagonists dose-dependently decreased response rates maintained by DTG or PRE-084, but did not affect cocaine self-administration. Response rates maintained by maximally effective DTG or PRE-084 doses were decreased by σR antagonists at lower doses than those that decreased response rates maintained by food reinforcement. Although σR antagonists block some cocaine-induced effects, the lack of effect on cocaine self-administration suggests that the primary reinforcing effects of cocaine do not involve direct effects at σRs. However, the self-administration of σR agonists in cocaine-trained subjects, facilitation of cocaine self-administration by σR-agonist pretreatment, and the facilitation of σR-agonist self-administration by WIN 35,428, together suggest enhanced abuse-related effects resulting from concomitant dopaminergically mediated actions and σR-mediated actions of the drugs. PMID:19892920
Beattie, W Scott; Wijeysundera, Duminda N; Karkouti, Keyvan; McCluskey, Stuart; Tait, Gordon
2008-04-01
Recent meta-analyses assessing the efficacy of perioperative beta-blockade trials have failed to show a reduction in postoperative morbidity and mortality. Tight control of heart rate (HR) has been suggested to improve these outcomes. Meta-analyses have not considered the influence of tight HR control on the efficacy of perioperative beta-blockade. Using previously published search strategies, we identified all randomized trials evaluating perioperative beta-blockers after noncardiac surgery. This search yielded 10 trials with 2176 patients. We used the data from these studies to correlate measures of HR control with major postoperative outcomes, primarily in-hospital myocardial infarction (MI). Odds ratio (OR) and 95% confidence intervals (CI) were calculated, and metaregression was performed correlating measures of HR control with MI. The combined results of all studies did not show a significant cardioprotective effect of beta-blockers, with considerable heterogeneity among the studies (OR = 0.76; 95% CI = 0.4-1.4; P = 0.38 heterogeneity: I(2) = 34%). However, grouping the trials on the basis of maximal HR showed that trials where the estimated maximal HR was <100 bpm were associated with cardioprotection (OR = 0.23; 95% CI = 0.08-0.65; P = 0.005) whereas trials where the estimated maximal HR was >100 bpm did not demonstrate cardioprotection (OR = 1.17; 95% CI = 0.79-1.80; P = 0.43) with no heterogeneity. Moreover, metaregression of the HR response to beta-blockade against the log OR of postoperative MI demonstrated a linear association between the effect of beta-blockade on the mean, maximal, and variation in HR and the OR of an MI (r(2) = 0.63; P < 0.001) where a larger effect of beta-blockers on HR was associated with a decreased incidence of postoperative MI. Across all studies, beta-blockade resulted in a reduction in postoperative HR (weighted mean difference: 8.6 bpm; 95% CI = -9.6 to -7.6; I(2) = 85.3%) with considerable heterogeneity. This large heterogeneity in HR response to beta-blockade was found to be related, in part, to the type of beta-blocker, specifically, metoprolol, and the concomitant use of calcium channel blockers. Calcium channel blocker use and beta-blockers other than metoprolol resulted in more effective control of HR. There was wide variability in the HR response to beta-blockade. Twenty-five percent of patients receiving beta-blockers had episodes when the HRs were more than 100 bpm, although 15% of placebo patients also had bradycardia, which would have required a dose reduction had they been administered beta-blockers. Finally, this analysis found that perioperative beta-blockade was associated with an increased incidence of bradycardia (OR = 3.49; 95% CI = 2.4-5.9) and congestive heart failure (OR = 1.68; 95% CI = 1.00-2.8). The trials that achieve the most effective control of HR are associated with a reduced incidence of postoperative MI, suggesting that effective control of HR is important for achieving cardioprotection. Second, this analysis demonstrates that administration of beta-blockers does not reliably decrease HRs in all patients, and may be associated with increased side effects. Judicious use of combination therapy with other drugs may be necessary to achieve effective postoperative control of HR.
The Characterization and Treatment of Aggressive Breast Cancer
2005-05-01
of a cycle for over 7 days, the carboplatin dose will be decreased by 25% for subsequent cycles. For a second episode of febrile neutropenia , G-CSF...should be given with the next cycle. For an episode of febrile neutropenia despite dose reduction and G-CSF, protocol treatment should be discontinued... neutropenia despite a dose reduction in the previous course. G-CSF may also be used as clinically indicated for neutropenic infection. 4.2.4 The use of
Pediatric CT and radiation: our responsibility
NASA Astrophysics Data System (ADS)
Frush, Donald P.
2009-02-01
In order to discuss the cost-benefit ratio of CT examinations in children, one must be familiar with the reasons why CT can provide a high collective or individual dose. The reasons include increasing CT use as well as lack of attention to dose reduction strategies. While those have been substantial efforts for dose reduction, additional work is necessary to prevent unnecessary radiation exposure. This responsibility is shared between science and medicine, industry, regulatory agencies, and patients as well.
The effects of perphenazine on self-administration behavior.
Johanson, C E; Kandel, D A; Bonese, K
1976-04-01
In Experiment 1.6 rhesus monkeys prepared with intravenous catheters responded on a fixed-ratio 10 schedule for either an injection of 0.2 mg/kg of cocaine or 0.5 mg/kg of pentobarbital during a daily 3 hr session. The substitution of saline or various doses of perphenazine resulted in very low rates of responding. These results indicate that perphenazine is not a positive reinforcer. Pretreating animals maintained on 0.1 mg/kg or 0.2 mg/kg of cocaine with perphenazine resulted in increases in rate of self-administration at some doses and a decrease in rate at higher doses. The dose of perphenazine which resulted in the maximal increase in cocaine self-administration was directly related to the dose of cocaine maintaining responding. Pretreating animals maintained on 0.5 mg/kg of pentobarbital with perphenazine had no effect at doses which increased cocaine self-administration but decreased rate of pentobarbital self-administration at higher doses. These results indicate that perphenazine is capable of antagonizing some of the effects of cocaine.
Quantities for assessing high photon doses to the body: a calculational approach.
Eakins, Jonathan S; Ainsbury, Elizabeth A
2018-06-01
Tissue reactions are the most clinically significant consequences of high-dose exposures to ionising radiation. However, currently there is no universally recognized dose quantity that can be used to assess and report generalised risks to individuals following whole body exposures in the high-dose range. In this work, a number of potential dose quantities are presented and discussed, with mathematical modelling techniques employed to compare them and explore when their differences are most or least manifest. The results are interpreted to propose the average (D GRB ) of the absorbed doses to the stomach, small intestine, red bone marrow, and brain as the optimum quantity for informing assessments of risk. A second, maximally conservative dose quantity (D Max ) is also suggested, which places limits on any under-estimates resulting from the adoption of D GRB . The primary aim of this work is to spark debate, with further work required to refine the final choice of quantity or quantities most appropriate for the full range of different potential exposure scenarios.
Effectiveness of disinfectant treatments for inactivating Piscirickettsia salmonis.
Muniesa, A; Escobar-Dodero, J; Silva, N; Henríquez, P; Bustos, P; Perez, A M; Mardones, F O
2018-03-08
This short communication investigated in vitro differences between commercial disinfectants types (n = 36), doses of application, and time of action in the elimination of Piscirickettsia salmonis, the most important bacterium affecting farmed salmon in Chile. Seven different treatments were examined, including active and inactive chlorine dioxides, glutaraldehyde, hypochlorite disinfectants and detergents, peracetic acid, peroxides and other miscellaneous methods A 3 replicate set of each of the sample groups was stored at 20 °C and 95% relative humidity and retested after 1, 5 and 30 min with varying doses (low, recommended and high doses). Multiple comparison tests were performed for the mean log CFU/ml among different disinfectant types, dose (ppm) and time of exposure (minutes) on the reduction of P. salmonis. Overall, disinfection using peracetic acid, peroxides, and both active and inactive chlorine dioxides caused significantly higher reduction of >7.5 log CFU/ml in samples, compared to other tested sanitizers. The lowest reduction was obtained after disinfection with hypochlorite detergents. As expected, as doses and time of action increase, there was a significant reduction of the overall counts of P. salmonis. However, at lowest doses, only use of paracetic acids resulted in zero counts. Implementation of effective protocols, making use of adequate disinfectants, may enhance biosecurity, and ultimately, mitigate the impact of P. salmonis in farmed salmon. Copyright © 2018. Published by Elsevier B.V.
An evaluation of in vivo models for toxicokinetics of hexavalent chromium in the stomach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sasso, A.F., E-mail: sasso.alan@epa.gov; Schlosser, P.M., E-mail: schlosser.paul@epa.gov
Hexavalent chromium (Cr6) is a drinking water contaminant that has been detected in most of the water systems throughout the United States. In 2-year drinking water bioassays, the National Toxicology Program (NTP) found clear evidence of carcinogenic activity in male and female rats and mice. Because reduction of Cr6 to trivalent chromium (Cr3) is an important detoxifying step in the gastrointestinal (GI) tract prior to systemic absorption, models have been developed to estimate the extent of reduction in humans and animals. The objective of this work was to use a revised model of ex vivo Cr6 reduction kinetics in gastricmore » juice to analyze the potential reduction kinetics under in vivo conditions for mice, rats and humans. A published physiologically-based pharmacokinetic (PBPK) model was adapted to incorporate the new reduction model. This paper focuses on the toxicokinetics of Cr6 in the stomach compartment, where most of the extracellular Cr6 reduction is believed to occur in humans. Within the range of doses administered by the NTP bioassays, neither the original nor revised models predict saturation of stomach reducing capacity to occur in vivo if applying default parameters. However, both models still indicate that mice exhibit the lowest extent of reduction in the stomach, meaning that a higher percentage of the Cr6 dose may escape stomach reduction in that species. Similarly, both models predict that humans exhibit the highest extent of reduction at low doses. - Highlights: • We outline a new in vivo model for hexavalent chromium reduction in the stomach. • We examine in vivo reduction for mice, rats, and humans under varying conditions. • Species differences in toxicokinetics may explain susceptibility. • We show that a simplified stomach reduction model is adequate for extrapolation. • Internal dose uncertainties still exist.« less
Turboelectric Distributed Propulsion in a Hybrid Wing Body Aircraft
NASA Technical Reports Server (NTRS)
Felder, James L.; Brown, Gerald V.; DaeKim, Hyun; Chu, Julio
2011-01-01
The performance of the N3-X, a 300 passenger hybrid wing body (HWB) aircraft with turboelectric distributed propulsion (TeDP), has been analyzed to see if it can meet the 70% fuel burn reduction goal of the NASA Subsonic Fixed Wing project for N+3 generation aircraft. The TeDP system utilizes superconducting electric generators, motors and transmission lines to allow the power producing and thrust producing portions of the system to be widely separated. It also allows a small number of large turboshaft engines to drive any number of propulsors. On the N3-X these new degrees of freedom were used to (1) place two large turboshaft engines driving generators in freestream conditions to maximize thermal efficiency and (2) to embed a broad continuous array of 15 motor driven propulsors on the upper surface of the aircraft near the trailing edge. That location maximizes the amount of the boundary layer ingested and thus maximizes propulsive efficiency. The Boeing B777-200LR flying 7500 nm (13890 km) with a cruise speed of Mach 0.84 and an 118100 lb payload was selected as the reference aircraft and mission for this study. In order to distinguish between improvements due to technology and aircraft configuration changes from those due to the propulsion configuration changes, an intermediate configuration was included in this study. In this configuration a pylon mounted, ultra high bypass (UHB) geared turbofan engine with identical propulsion technology was integrated into the same hybrid wing body airframe. That aircraft achieved a 52% reduction in mission fuel burn relative to the reference aircraft. The N3-X was able to achieve a reduction of 70% and 72% (depending on the cooling system) relative to the reference aircraft. The additional 18% - 20% reduction in the mission fuel burn can therefore be attributed to the additional degrees of freedom in the propulsion system configuration afforded by the TeDP system that eliminates nacelle and pylon drag, maximizes boundary layer ingestion (BLI) to reduce inlet drag on the propulsion system, and reduces the wake drag of the vehicle.
Mollard, P; Woorons, X; Letournel, M; Cornolo, J; Lamberto, C; Beaudry, M; Richalet, J-P
2007-03-01
We aimed to evaluate 1) the altitude where maximal heart rate (HR (max)) decreases significantly in both trained and untrained subjects in moderate acute hypoxia, and 2) if the HR (max) decrease could partly explain the drop of V.O (2max). Seventeen healthy males, nine trained endurance athletes (TS) and eight untrained individuals (US) were studied. Subjects performed incremental exercise tests at sea level and at 5 simulated altitudes (1000, 1500, 2500, 3500, 4500 meters). Power output (PO), heart rate (HR), arterial oxygen saturation (SaO (2)), oxygen uptake (V.O (2)), arterialized blood pH and lactate were measured. Both groups showed a progressive reduction in V.O (2max). The decrement in HR (max) (DeltaHR (max)) was significant from 1000 m for TS and 2500 m for US and more important in TS than US (at 1500 m and 3500 m). At maximal exercise, TS had a greater reduction in SaO (2) (DeltaSaO (2)) at each altitude. DeltaHR (max) observed in TS was correlated with DeltaSaO (2). When the two groups were pooled, simple regressions showed that DeltaV.O (2max) was correlated with both DeltaSaO (2) and DeltaHR (max). However, a multiple regression analysis demonstrated that DeltaSaO (2) alone may account for DeltaV.O (2max). Furthermore, in spite of a greater reduction in SaO (2) and HR (max) in TS, no difference was evidenced in relative DeltaV.O (2max) between groups. Thus, in moderate acute hypoxia, the reduction in SaO (2) is the primary factor to explain the drop of V.O (2max) in trained and untrained subjects.
A portable thermal imaging device as a feedback system for breast cancer treatment
NASA Astrophysics Data System (ADS)
Hoffer, Oshrit A.; Ben-David, Merav A.; Katz, Eyal; Sholomov, Meny; Kelson, Itzhak; Gannot, Israel
2018-02-01
Breast cancer is the most frequently diagnosed cancer among women in the Western world. Currently, no imaging technique assesses tumor heat generation and vasculature changes during radiotherapy in viable tumor and as adjuvant therapy. Thermography is a non-ionizing, non-invasive, portable and low-cost imaging modality. The purpose of this study was to investigate the use of thermography in cancer treatment monitoring for feedback purposes. Six stage-IV breast cancer patients with viable breast tumor and 8 patients (9 breasts) who underwent tumor resection were monitored by a thermal camera prior to radiotherapy sessions over several weeks of radiation treatment. The thermal changes over the treated breast were calculated and analyzed for comparison with healthy surrounded breast tissue or contralateral breast. A model of a breast with a tumor was created. The COMSOL FEM software was used to carry out the analysis. The effects of tumor metabolism and breast tissue perfusion on the temperature difference were analyzed. All patients with active tumors exhibited drops in maximal temperature of the tumor during radiation therapy. The patients who underwent radiotherapy as adjuvant treatment exhibited a rise in maximal temperature over the treated breast in correlation with skin erythema during radiation. This difference between the groups was statistically significant (P=0.001). The simulated human breast cancer models analysis showed that tumor aggressiveness reduction causes decrease in the tumor temperature. Inflammation causes vasodilatation and increases tissue perfusion, resulted in an increase in breast tissue temperature. A correlation was demonstrated between the clinical outcome and the simulation. We report a method for monitoring cancer response to radiation therapy, which measures the physiological response along with clinical response. These anticipatory efficacy evaluations of radiotherapy during treatment may further promote changes in treatment regimen, either radiation associated or combination as in chemo-radiation protocols. The probable treatment delivery changes may incorporate the total dose delivery, fraction dose and intensity as well as adding chemotherapy for non-responding tumors during radiotherapy. All the above possibilities will contribute to the advances of individualized, personalized cancer treatment for optimal treatment effectiveness.
RADIATION PROTECTION CABIN FOR CATHETER-DIRECTED LIVER INTERVENTIONS: OPERATOR DOSE ASSESSMENT.
Maleux, Geert; Bergans, Niki; Bosmans, Hilde; Bogaerts, Ria
2016-09-01
The number and complexity of interventional radiological procedures and in particular catheter-directed liver interventions have increased substantially. The current study investigates the reduction of personal doses when using a dedicated radiation protection cabin (RPC) for these procedures. Operator and assistant doses were assessed for 3 series of 20 chemoinfusion/chemoembolisation interventions, including an equal number of procedures with and without RPC. Whole body doses, finger doses and doses at the level of knees and eyes were evaluated with different types of TLD-100 Harshaw dosemeters. Dosemeters were also attached on the three walls of the RPC. The operator doses were significantly reduced by the RPC, but also without RPC, the doses appear to be limited as a result of thorough optimisation with existing radiation protection tools. The added value of the RPC should thus be determined by the outcome of balancing dose reduction and other aspects such as ergonomic benefits. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Roessler, Ann-Christin; Hupfer, Martin; Kolditz, Daniel; Jost, Gregor; Pietsch, Hubertus; Kalender, Willi A
2016-04-01
Spectral optimization of x-ray computed tomography (CT) has led to substantial radiation dose reduction in contrast-enhanced CT studies using standard iodinated contrast media. The purpose of this study was to analyze the potential for further dose reduction using high-atomic-number elements such as hafnium and tungsten. As in previous studies, spectra were determined for which the patient dose necessary to provide a given contrast-to-noise ratio (CNR) is minimized. We used 2 different quasi-anthropomorphic phantoms representing the liver cross-section of a normal adult and an obese adult patient with the lateral widths of 360 and 460 mm and anterior-posterior heights of 200 and 300 mm, respectively. We simulated and measured on 2 different scanners with x-ray spectra from 80 to 140 kV and from 70 to 150 kV, respectively. We determined the contrast for iodine-, hafnium-, and tungsten-based contrast media, the noise, and 3-dimensional dose distributions at all available tube voltages by measurements and by simulations. The dose-weighted CNR was determined as optimization parameter. Simulations and measurements were in good agreement regarding their dependence on energy for all parameters investigated. Hafnium provided the best performance for normal and for obese patient phantoms, indicating a dose reduction potential of 30% for normal and 50% for obese patients at 120 kV compared with iodine; this advantage increased further with higher kV values. Dose-weighted CNR values for tungsten were always slightly below the hafnium results. Iodine proved to be the superior choice at voltage values of 80 kV and below. Hafnium and tungsten both seem to be candidates for contrast-medium-enhanced CT of normal and obese adult patients with strongly reduced radiation dose at unimpaired image quality. Computed tomography examinations of obese patients will decrease in dose for higher kV values.
SU-G-IeP2-10: Lens Dose Reduction by Patient Position Modification During Neck CT Exams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mosher, E; Lee, C; Butman, J
Purpose: Irradiation of the lens during a neck CT may increase a patient’s risk of developing cataracts later in life. Radiologists and technologists at the National Institutes of Health Clinical Center (NIHCC) have developed new CT imaging protocols that include a reduction in scan range and modifying neck positioning using a head tilt. This study will evaluate the efficacy of this protocol in the reduction of lens dose. Methods: We retrieved CT images of five male patients who had two sets of CT images: before and after the implementation of the new protocol. The lens doses before the new protocolmore » were calculated using an in-house CT dose calculator, National Cancer Institute dosimetry system for CT (NCICT), where computational human phantoms with no head tilt are included. We also calculated the lens dose for the patient CT conducted after the new protocol by using an adult male computational phantom with the neck position deformed to match the angle of the head tilt. We also calculated the doses to other radiosensitive organs including the globes of the eye, brain, pituitary gland and salivary glands before and after head tilt. Results: Our dose calculations demonstrated that modifying neck position reduced dose to the lens by 89% on average (range: 86–96%). Globe, brain, pituitary and salivary gland doses also decreased by an average of 65% (51–95%), 38% (−8–66%), 34% (−43–84%) and 14% (13–14%), respectively. The new protocol resulted in a nearly ten-fold decrease in lens dose. Conclusion: The use of a head tilt and scan range reduction is an easy and effective method to reduce radiation exposure to the lens and other radiosensitive organs, while still allowing for the inclusion of critical neck structures in the CT image. We are expanding our study to a total of 10 males and 10 females.« less
Slater, B J; Varma, J S; Gillespie, J I
1997-02-01
The underlying pathophysiology of idiopathic slow transit constipation (ISTC) remains unclear. At present, there is little evidence to implicate a smooth muscle myopathy in the aetiology of this condition. This study compared the effect of cisapride on the cholinergic response of colonic muscle strips from patients with this condition with that of control tissue. Isometric tension production was recorded from circular smooth muscle strips taken from five patients undergoing colectomy for ISTC in response to cumulative concentrations of carbachol (100 nmol/1-100 mumol/l) alone and in the presence of cisapride 400 nmol/l. Similar dose-response activity was obtained for a control group consisting of six patients undergoing resection for colorectal carcinoma. In the absence of cisapride, smooth muscle from patients with carcinoma exhibited a significantly lower sensitivity to cholinergic stimulation (agonist concentration required to produce half-maximal activation (EC50) 4.83 mumol/l) than that from patients with ISTC (EC50 1.63 mumol/l, P = 0.036), and also a greater maximal frequency of the oscillatory activity associated with the increase in isometric tension (0.070 versus 0.049 Hz, P = 0.035). Cisapride had no effect on the sensitivity to carbachol of the carcinoma tissue but brought about a significant reduction in the sensitivity of smooth muscle from patients with ISTC (EC50 3.24 mumol/l, P = 0.043). These findings indicate that colonic smooth muscle from patients with ISTC is hypersensitive to cholinergic stimulation and suggest the existence of a smooth muscle myopathy in this condition.
The impact of overdiagnosis on the selection of efficient lung cancer screening strategies.
Han, Summer S; Ten Haaf, Kevin; Hazelton, William D; Munshi, Vidit N; Jeon, Jihyoun; Erdogan, Saadet A; Johanson, Colden; McMahon, Pamela M; Meza, Rafael; Kong, Chung Yin; Feuer, Eric J; de Koning, Harry J; Plevritis, Sylvia K
2017-06-01
The U.S. Preventive Services Task Force (USPSTF) recently updated their national lung screening guidelines and recommended low-dose computed tomography (LDCT) for lung cancer (LC) screening through age 80. However, the risk of overdiagnosis among older populations is a concern. Using four comparative models from the Cancer Intervention and Surveillance Modeling Network, we evaluate the overdiagnosis of the screening program recommended by USPSTF in the U.S. 1950 birth cohort. We estimate the number of LC deaths averted by screening (D) per overdiagnosed case (O), yielding the ratio D/O, to quantify the trade-off between the harms and benefits of LDCT. We analyze 576 hypothetical screening strategies that vary by age, smoking, and screening frequency and evaluate efficient screening strategies that maximize the D/O ratio and other metrics including D and life-years gained (LYG) per overdiagnosed case. The estimated D/O ratio for the USPSTF screening program is 2.85 (model range: 1.5-4.5) in the 1950 birth cohort, implying LDCT can prevent ∼3 LC deaths per overdiagnosed case. This D/O ratio increases by 22% when the program stops screening at an earlier age 75 instead of 80. Efficiency frontier analysis shows that while the most efficient screening strategies that maximize the mortality reduction (D) irrespective of overdiagnosis screen through age 80, screening strategies that stop at age 75 versus 80 produce greater efficiency in increasing life-years gained per overdiagnosed case. Given the risk of overdiagnosis with LC screening, the stopping age of screening merits further consideration when balancing benefits and harms. © 2017 UICC.
Klemm, Rolf D W; Palmer, Amanda C; Greig, Alison; Engle-Stone, Reina; Dalmiya, Nita
2016-06-01
Vitamin A deficiency (VAD) remains a widespread public health problem in the developing world, despite changes in under-5 mortality rates, morbidity patterns, and intervention options. This article considers the implications of a changing epidemiologic and programmatic landscape for vitamin A (VA) programs. We review progress to prevent VAD and its health consequences, assess gaps in VA status and intervention coverage data, and assess data needed to guide decisions regarding the optimal mix, targeting, and dose of VA interventions to maximize benefit and minimize risk. Vitamin A supplementation programs have contributed to the reduction in under-5 mortality rates, but alone, do not address the underlying problem of inadequate dietary VA intakes and VAD among preschool-aged children in the developing world. A combination of VA interventions (eg, supplementation, fortified foods, multiple micronutrient powders, and lipid-based nutrient supplements) will be required to achieve VA adequacy in most settings. Current efforts to measure the coverage of multiple VA interventions, as well as whether and how much VA children are receiving, are few and fragmented. Where intervention overlap exists, further effort is needed to monitor VA intakes, ensuring that targeted groups are consuming adequate amounts but not exceeding the tolerable upper intake level. Vitamin A status data will also be critical for navigating the changing landscape of VA programs. Data from these monitoring efforts will help to guide decisions on the optimal mix, targeting, and exposure to VA interventions to maximize public health benefit while minimizing any potential risk. © The Author(s) 2016.
Inserte, J; Najib, A; Pelliccioni, P; Gil, C; Aguilera, J
1999-01-01
Tetanus toxin (TeTx) is a powerful clostridial neurotoxin that inhibits Ca2+-dependent neurotransmitter secretion as do the botulinum neurotoxins (BoNTs). We found that TeTx (but not BoNT/A) produced a specific time- and dose-dependent inhibition of Na+-dependent [3H]5-hydroxytryptamine (serotonin, 5-HT) uptake in rat CNS synaptosomes. This effect was found in all CNS tryptaminergic areas, being maximal in the hippocampus and occipital cortex. TeTx produced the maximum reduction in [3H]5-HT uptake after 30 min of preincubation, being significant also at lower doses (10(-12) M) or shorter incubation times (10 min). Serotonin transport inhibitors such as fenfluramine (IC50, 11.0 +/- 0.9 microM), paroxetine (IC50, 33.5 +/- 0.1 microM), and imipramine (IC50, 89.9 +/- 5.7 microM) were 3 or 4 orders of magnitude less potent than TeTx (IC50, 8.7 +/- 1.0 nM). Of the two fragments of TeTx, (the C-terminal portion of the neurotoxin heavy chain, which is responsible for the binding to the nerve tissue) was consistently more effective than the L-H(N) fragment (the light neurotoxin chain disulfide linked to the N-terminal portion of the heavy chain, which is responsible for the toxic metalloprotease action) as inhibitor of [3H]5-HT uptake in synaptosomal preparations (56 +/- 5% and 95 +/- 3% with respect to control, respectively). Antagonism of the toxin-induced [3H]5-HT uptake blockade could not be reversed by zinc chelators but did have the ability to antagonize the TeTx inhibition of basal and K+-evoked [3H]5-HT release in rat synaptosomes. The reduction in serotonin accumulation induced by TeTx could be responsible for some tetanic symptoms that have been related to the serotonergic system.
Gosteev, A Iu; Zorin, A V; Rodnenkov, O V; Dragnev, A G; Chazov, E I
2014-01-01
To examine the antihypertensive effect of the synthetic analogue of the endogenous nitric oxide donors in patients with grades 2-3 hypertension and uncomplicated hypertensive crisis (HC). The study included 30 male patients aged 35 to 73 years (mean age 55.5 ± 10.8 years). All the patients had grades 2-3 essential or secondary hypertension. Thirteen (43.3%) patients were observed to have signs of HC; 17 (56.7%) patients had persistent blood pressure (BP) elevation. A dinitrosyl iron complex was injected in a dose of 1.5 or 3 mg per kg of body weight. The purpose of its administration was to lower BP by at least 20% of its baseline level. No significant side effects associated with the administration of the test drug were recorded when the clinical trial protocol was implemented. All the patients reported fever and facial hyperemia during and 10-20 minutes after injection. They all (100%) showed efficient blood pressure reduction of at least 20% of the baseline level. Blood pressure changes were similar when the agent was administered in doses of 1.5 or 3 mg/kg. At 6-8 minutes after the drug was injected, there was a maximal decrease in blood pressure, then its gradual rise and stabilization at a lower level than the baseline one within the following 8 hours. There were no significant differences in the magnitude of a blood pressure reduction after administration of 1.5 and 3 mg/kg. The findings suggest that the dinitrosyl iron complex is highly effective in treating uncomplicated HC. The antihypertensive effect of the drug persists for 8 hours after its injection, which is very important during prehospital therapy. The drug is well tolerated by patients and causes an insignificant number of side effects.
A test of ecological optimality for semiarid vegetation. M.S. Thesis
NASA Technical Reports Server (NTRS)
Salvucci, Guido D.; Eagleson, Peter S.; Turner, Edmund K.
1992-01-01
Three ecological optimality hypotheses which have utility in parameter reduction and estimation in a climate-soil-vegetation water balance model are reviewed and tested. The first hypothesis involves short term optimization of vegetative canopy density through equilibrium soil moisture maximization. The second hypothesis involves vegetation type selection again through soil moisture maximization, and the third involves soil genesis through plant induced modification of soil hydraulic properties to values which result in a maximum rate of biomass productivity.
SU-F-T-325: On the Use of Bolus in Dosimetry and Dose Reduction for Pacemaker and Defibrillator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, W; Kenneth, R; Higgins, S
Purpose: Special attention is required in planning and administering radiation therapy to patients with cardiac implantable electronic devices (CIEDs), such as pacemaker and defibrillator. The range of dose to CIEDs that can induce malfunction is very large among CIEDs. Significant defects have been reported at dose as low as 0.15Gy. Failures causing discomfort have been reported at dose as low as 0.05Gy. Therefore, accurate estimation of dose to CIED and dose reduction are both important even if the dose is expected to be less than the often-used 2Gy limit. We investigate the use of bolus in in vivo dosimetry formore » CIEDs. Methods: In our clinic, high-energy beams (>10MV) are not used for patients with CIED due to neutron production. Solid water phantom measurements of out-of-field dose for a 6MV beam were performed using parallel plate chamber at different depth with and without 2cm bolus covering the chamber. In vivo dosimetry at skin surface above the pacemaker was performed with and without bolus for 3 patients with pacemaker <5cm from the field edge. Results: Chamber measured dose at depth ∼1 to 1.5cm below the skin surface, where the CIED is normally located, was reduced by ∼6% – 20% with bolus. The dose reduction became smaller at deeper depth. In vivo dosimetry at skin surface also yielded ∼20% – 60% lower dose when using bolus for the 3 patients. In general, TPS calculation underestimated the dose. The dose measured with bolus is closer to the dose at the depth of the pacemaker and less affected by contaminant electrons and linac head leakage. Conclusion: In vivo CIED dose measurements should be performed with 1 to 2cm bolus covering the dosimeter on the skin above the CIED for more accurate CIED dose estimation. The use of bolus also reduces the dose delivered to CIED.« less
Effect of harmane on the convulsive threshold in epilepsy models in mice.
Aricioglu, Feyza; Yillar, Okan; Korcegez, Eylem; Berkman, Kemal
2003-12-01
The study investigated the activity of harmane on maximal electroshock seizures (MES) and seizures induced by pentilentetrazole (PTZ) in mice. Initial studies established convulsive current 50 (CC(50)) values or MES and effective dose 50 (ED(50)) for PTZ to produce seizures. Harmane (2.5, 5.0, or 10 mg/kg intraperitoneally) increased the threshold of seizures in MES dose-dependently. The convulsions produced by PTZ were decreased by the low dose of harmane (2.5 mg/kg), but the high dose of harmane (10 mg/kg) resulted in worse grade V convulsions followed by more lethality compared with PTZ alone. Therefore, harmane seems to be protective against grand mal seizures in the MES model but not against a petit mal seizure model (PTZ) in mice.
Deformable 3D-2D registration for CT and its application to low dose tomographic fluoroscopy
NASA Astrophysics Data System (ADS)
Flach, Barbara; Brehm, Marcus; Sawall, Stefan; Kachelrieß, Marc
2014-12-01
Many applications in medical imaging include image registration for matching of images from the same or different modalities. In the case of full data sampling, the respective reconstructed images are usually of such a good image quality that standard deformable volume-to-volume (3D-3D) registration approaches can be applied. But research in temporal-correlated image reconstruction and dose reductions increases the number of cases where rawdata are available from only few projection angles. Here, deteriorated image quality leads to non-acceptable deformable volume-to-volume registration results. Therefore a registration approach is required that is robust against a decreasing number of projections defining the target position. We propose a deformable volume-to-rawdata (3D-2D) registration method that aims at finding a displacement vector field maximizing the alignment of a CT volume and the acquired rawdata based on the sum of squared differences in rawdata domain. The registration is constrained by a regularization term in accordance with a fluid-based diffusion. Both cost function components, the rawdata fidelity and the regularization term, are optimized in an alternating manner. The matching criterion is optimized by a conjugate gradient descent for nonlinear functions, while the regularization is realized by convolution of the vector fields with Gaussian kernels. We validate the proposed method and compare it to the demons algorithm, a well-known 3D-3D registration method. The comparison is done for a range of 4-60 target projections using datasets from low dose tomographic fluoroscopy as an application example. The results show a high correlation to the ground truth target position without introducing artifacts even in the case of very few projections. In particular the matching in the rawdata domain is improved compared to the 3D-3D registration for the investigated range. The proposed volume-to-rawdata registration increases the robustness regarding sparse rawdata and provides more stable results than volume-to-volume approaches. By applying the proposed registration approach to low dose tomographic fluoroscopy it is possible to improve the temporal resolution and thus to increase the robustness of low dose tomographic fluoroscopy.