Ishida, Kazunari; Shibanuma, Nao; Matsumoto, Tomoyuki; Sasaki, Hiroshi; Takayama, Koji; Matsuzaki, Tokio; Tei, Katsumasa; Kuroda, Ryosuke; Kurosaka, Masahiro
2016-01-01
To investigate whether intraoperative kinematics obtained by navigation systems can be divided into several kinematic patterns and to assess the correlation between the intraoperative kinematics with maximum flexion angles before and after total knee arthroplasty (TKA). Fifty-four posterior-stabilised (PS) TKA implanted using an image-free navigation system were evaluated. At registration and after implantation, tibial internal rotation angles at maximum extension, 30°, 45°, 60°, 90°, and maximum flexion were collected. The rotational patterns were divided into four groups and were examined the correlation with maximum flexion before and after operation. Tibial internal rotation from 90° of flexion to maximum flexion at registration was correlated with maximum flexion angles pre- and postoperatively. The four groups showed statistically different kinematic patterns. The group with tibial external rotation up to 90° of flexion, following tibial internal rotation at registration, achieved better flexion angles, compared to those of another groups (126.7° ± 12.0°, p < 0.05). The group with tibial external rotation showed the worst flexion angles (80.0° ± 40.4°, p < 0.05). Furthermore, the group with limited extension showed worse flexion angles (111.6° ± 8.9°, p < 0.05). Navigation-based kinematic patterns found at registration predict postoperative maximum flexion angle in PS TKA. Navigation-based kinematics can be useful information during TKA surgery. Diagnostic studies, development of diagnostic criteria in a consecutive series of patients and a universally applied "gold" standard, Level II.
Walker, Peter S; Yildirim, Gokce; Sussman-Fort, Jon; Roth, Jonathan; White, Brian; Klein, Gregg R
2007-08-01
Maximum flexion-or impingement angle-is defined as the angle of flexion when the posterior femoral cortex impacts the posterior edge of the tibial insert. We examined the effects of femoral component placement on the femur, the slope angle of the tibial component, the location of the femoral-tibial contact point, and the amount of internal or external rotation. Posterior and proximal femoral placement, a more posterior femoral-tibial contact point, and a more tibial slope all increased maximum flexion, whereas rotation reduced it. A mobile-bearing knee gave results similar to those of the fixed-bearing knee, but there was no loss of flexion in internal or external rotation if the mobile bearing moved with the femur. In the absence of negative factors, a flexion angle of 150 degrees can be reached before impingement.
Tom, Stephanie; Frayne, Mark; Manske, Sarah L; Burghardt, Andrew J; Stok, Kathryn S; Boyd, Steven K; Barnabe, Cheryl
2016-10-01
The position-dependence of a method to measure the joint space of metacarpophalangeal (MCP) joints using high-resolution peripheral quantitative computed tomography (HR-pQCT) was studied. Cadaveric MCP were imaged at 7 flexion angles between 0 and 30 degrees. The variability in reproducibility for mean, minimum, and maximum joint space widths and volume measurements was calculated for increasing degrees of flexion. Root mean square coefficient of variance values were < 5% under 20 degrees of flexion for mean, maximum, and volumetric joint spaces. Values for minimum joint space width were optimized under 10 degrees of flexion. MCP joint space measurements should be acquired at < 10 degrees of flexion in longitudinal studies.
Reliability and validity of the Microsoft Kinect for assessment of manual wheelchair propulsion.
Milgrom, Rachel; Foreman, Matthew; Standeven, John; Engsberg, Jack R; Morgan, Kerri A
2016-01-01
Concurrent validity and test-retest reliability of the Microsoft Kinect in quantification of manual wheelchair propulsion were examined. Data were collected from five manual wheelchair users on a roller system. Three Kinect sensors were used to assess test-retest reliability with a still pose. Three systems were used to assess concurrent validity of the Kinect to measure propulsion kinematics (joint angles, push loop characteristics): Kinect, Motion Analysis, and Dartfish ProSuite (Dartfish joint angles were limited to shoulder and elbow flexion). Intraclass correlation coefficients revealed good reliability (0.87-0.99) between five of the six joint angles (neck flexion, shoulder flexion, shoulder abduction, elbow flexion, wrist flexion). ICCs suggested good concurrent validity for elbow flexion between the Kinect and Dartfish and between the Kinect and Motion Analysis. Good concurrent validity was revealed for maximum height, hand-axle relationship, and maximum area (0.92-0.95) between the Kinect and Dartfish and maximum height and hand-axle relationship (0.89-0.96) between the Kinect and Motion Analysis. Analysis of variance revealed significant differences (p < 0.05) in maximum length between Dartfish (mean 58.76 cm) and the Kinect (40.16 cm). Results pose promising research and clinical implications for propulsion assessment and overuse injury prevention with the application of current findings to future technology.
Anteroposterior translation does not correlate with knee flexion after total knee arthroplasty.
Ishii, Yoshinori; Noguchi, Hideo; Takeda, Mitsuhiro; Sato, Junko; Toyabe, Shin-ichi
2014-02-01
Stiffness after a TKA can cause patient dissatisfaction and diminished function, therefore it is important to characterize predictors of ROM after TKA. Studies of AP translation in conscious individuals disagree whether AP translation affects maximum knee flexion angle after implantation of a highly congruent sphere and trough geometry PCL-substituting prosthesis in a TKA. We investigated whether AP translation correlated with maximum knee flexion angle (1) in patients who were awake, and (2) who were under anesthesia (to minimize the effects of voluntary muscle contraction) in a TKA with implantation of a PCL-substituting mobile-bearing prosthesis. AP translation was examined under both conditions in 34 primary TKAs. Measurements under anesthesia were performed when the patients were having anesthesia for a contralateral TKA. Awake measurements were made within 4 days of that anesthetic session in patients who had no residual sedative effects. The average postoperative interval for the index TKA flexion measurements was 23 months (range, 6-114 months). AP translation was evaluated at 75° flexion using an arthrometer. There was no correlation between postoperative maximum knee flexion and AP translation at 75° during consciousness. There was no correlation between postoperative maximum knee flexion and AP translation under anesthesia. AP translation at 75° flexion did not correlate with postoperative maximum knee flexion in either awake or anesthetized patients during a TKA with implantation of a posterior cruciate-substituting prosthesis.
ERIC Educational Resources Information Center
Zebas, Carole J.
This study focuses on changes occurring in selected mechanical components of high school girls performing the standing broad jump, and collects data pertaining to the effects of monetary reward and videotape feedback upon the following components: (a) distance jumped, (b) maximum angle of knee flexion, (c) maximum angle of hip flexion, (d) hip…
Anderson, Dennis E; Madigan, Michael L; Nussbaum, Maury A
2007-01-01
Measurements of human strength can be important during analyses of physical activities. Such measurements have often taken the form of the maximum voluntary torque at a single joint angle and angular velocity. However, the available strength varies substantially with joint position and velocity. When examining dynamic activities, strength measurements should account for these variations. A model is presented of maximum voluntary joint torque as a function of joint angle and angular velocity. The model is based on well-known physiological relationships between muscle force and length and between muscle force and velocity and was tested by fitting it to maximum voluntary joint torque data from six different exertions in the lower limb. Isometric, concentric and eccentric maximum voluntary contractions were collected during hip extension, hip flexion, knee extension, knee flexion, ankle plantar flexion and dorsiflexion. Model parameters are reported for each of these exertion directions by gender and age group. This model provides an efficient method by which strength variations with joint angle and angular velocity may be incorporated into comparisons between joint torques calculated by inverse dynamics and the maximum available joint torques.
Choi, Chong Hyuk; Kim, Sung-Jae; Chun, Yong-Min; Kim, Sung-Hwan; Lee, Su-Keon; Eom, Nam-Kyu; Jung, Min
2018-01-01
The purpose of this study was to find appropriate flexion angle and transverse drill angle for optimal femoral tunnels of anteromedial (AM) bundle and posterolateral (PL) bundle in double-bundle ACL reconstruction using transportal technique. Thirty three-dimensional knee models were reconstructed. Knee flexion angles were altered from 100° to 130° at intervals of 10°. Maximum transverse drill angle (MTA), MTA minus 10° and 20° were set up. Twelve different tunnels were determined by four flexion angles and three transverse drill angles for each bundle. Tunnel length, wall breakage, inter-tunnel communication and graft-bending angle were assessed. Mean tunnel length of AM bundle was >30mm at 120° and 130° of flexion in all transverse drill angles. Mean tunnel length of PL bundle was >30mm during every condition. There were ≥1 cases of wall breakage except at 120° and 130° of flexion with MTA for AM bundle. There was no case of wall breakage for PL bundle. Considering inter-tunnel gap of >2mm without communication and obtuse graft-bending angle, 120° of flexion and MTA could be recommended as optimal condition for femoral tunnels of AM and PL bundles. Flexion angle and transverse drill angle had combined effect on femoral tunnel in double-bundle ACL reconstruction using transportal technique. Achieving flexion angle of 120° and transverse drill angle close to the medial femoral condyle could be recommended as optimal condition for femoral tunnels of AM and PL bundles to avoid insufficient tunnel length, wall breakage, inter-tunnel communication and acute graft-bending angle. Copyright © 2017 Elsevier B.V. All rights reserved.
Ishida, Kazunari; Shibanuma, Nao; Matsumoto, Tomoyuki; Sasaki, Hiroshi; Takayama, Koji; Hiroshima, Yuji; Kuroda, Ryosuke; Kurosaka, Masahiro
2016-08-01
In clinical practice, people with better femorotibial rotation in the flexed position often achieve a favourable postoperative maximum flexion angle (MFA). However, no objective data have been reported to support this clinical observation. In the present study, we aimed to investigate the correlation between the amount of intraoperative rotation and the pre- and postoperative flexion angles. Fifty-five patients with varus osteoarthritis undergoing computer-assisted posterior-stabilized total knee arthroplasty (TKA) were enrolled. After registration, rotational stress was applied towards the knee joint, and the rotational angles were recorded by using a navigation system at maximum extension and 90° of flexion. After implantation, rotational stress was applied for a second time, and the angles were recorded once more. The MFA was measured before surgery and 1 month after surgery, and the correlation between the amount of femorotibial rotation during surgery and the MFA was statistically evaluated. Although the amount of tibial rotation at maximum extension was not correlated with the MFA, the amount of tibial rotation at 90° of flexion after registration was positively correlated with the pre- and postoperative MFA (both p < 0.005). However, no significant relationship was observed between the amount of tibial rotation after implantation and the postoperative MFA (n.s.). The results showed that better femorotibial rotation at 90° of flexion is associated with a favourable postoperative MFA, suggesting that the flexibility of the surrounding soft tissues is an important factor for obtaining a better MFA, which has important clinical relevance. Hence, further evaluation of navigation-based kinematics during TKA may provide useful information on MFA. Diagnostic studies, development of diagnostic criteria in a consecutive series of patients, and a universally applied "gold" standard, Level II.
De Carvalho, Diana; Grondin, Diane; Callaghan, Jack
2017-10-01
The purpose of this study was to determine which office chair feature is better at improving spine posture in sitting. Participants (n = 28) were radiographed in standing, maximum flexion and seated in four chair conditions: control, lumbar support, seat pan tilt and backrest with scapular relief. Measures of lumbar lordosis, intervertebral joint angles and sacral tilt were compared between conditions and sex. Sitting consisted of approximately 70% of maximum range of spine flexion. No differences in lumbar flexion were found between the chair features or control. Significantly more anterior pelvic rotation was found with the lumbar support (p = 0.0028) and seat pan tilt (p < 0.0001). Males had significantly more anterior pelvic rotation and extended intervertebral joint angles through L1-L3 in all conditions (p < 0.0001). No one feature was statistically superior with respect to minimising spine flexion, however, seat pan tilt resulted in significantly improved pelvic posture. Practitioner Summary: Seat pan tilt, and to some extent lumbar supports, appear to improve seated postures. However, sitting, regardless of chair features used, still involves near end range flexion of the spine. This will increase stresses to the spine and could be a potential injury generator during prolonged seated exposures.
Perez-Blanca, Ana; Espejo-Baena, Alejandro; Amat Trujillo, Daniel; Prado Nóvoa, María; Espejo-Reina, Alejandro; Quintero López, Clara; Ezquerro Juanco, Francisco
2016-04-01
To compare the effects of lateral meniscus posterior root avulsion left in situ, its repair, and meniscectomy on contact pressure distribution in both tibiofemoral compartments at different flexion angles. Eight cadaveric knees were tested under compressive 1000 N load for 4 lateral meniscus conditions (intact, posterior root avulsion, transosseous root repair, and total meniscectomy) at flexion angles 0°, 30°, 60°, and 90°. Contact area and pressure distribution were registered using K-scan pressure sensors inserted between menisci and tibial plateau. In the lateral compartment, root detachment decreased contact area (P = .017, 0° and 30°; P = .012, 60° and 90°) and increased mean (P = .012, all angles) and maximum (P = .025, 0° and 30°; P = .017, 60°; P = .012, 90°) pressures relative to intact condition. Repair restored all measured parameters close to intact at 0°, but effectiveness decreased with flexion angle, yielding no significant effect at 90°. Meniscectomy produced higher decreases than root avulsion in contact area (P = .012, 0° and 90°; P = .05, 30° and 60°) and increases in mean (P = .017, 0° and 30°; P = .018, 90°) and maximum pressure (P = .012, 0°; P = .036, 30°). In the medial compartment, lesion changed the contact area at high flexion angles only, while meniscectomy induced greater changes at all angles. Lateral meniscus posterior root avulsion generates significant alterations in contact area and pressures at lateral knee compartment for flexion angles between full extension and 90°. Meniscectomy causes greater disorders than the avulsion left in situ. Transosseous repair with a single suture restores these alterations to conditions close to intact at 0° and 30° but not at 60° and 90°. Altered contact mechanics after lateral meniscus posterior root avulsion might have degenerative consequences. Transosseous repair with one suture should be revised to effectively restore contact mechanics at high flexion angles. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Lorenzetti, Silvio; Gülay, Turgut; Stoop, Mirjam; List, Renate; Gerber, Hans; Schellenberg, Florian; Stüssi, Edgar
2012-10-01
The aim of this study was to compare the angles and corresponding moments in the knee and hip during squats. Twenty subjects performed restricted and unrestricted squats with barbell loads that were 0, ¼, and ½ their body weight. The experimental setup consisted of a motion capture system and 2 force plates. The moments were calculated using inverse dynamics. During the unrestricted squats, the maximum moments in the knee were significantly higher, and those in the hip were significantly lower than during restricted squats. At the lowest position, the maximum knee flexion angles were approximately 86° for the restricted and approximately 106° for the unrestricted techniques, whereas the maximum hip flexion angle was between 95° and 100°. The higher moments in the hip during restricted squats suggest a higher load of the lower back. Athletes who aim to strengthen their quadriceps should consider unrestricted squats because of the larger knee load and smaller back load.
Wada, Keizo; Hamada, Daisuke; Tamaki, Shunsuke; Higashino, Kosaku; Fukui, Yoshihiro; Sairyo, Koichi
2017-01-01
Previous studies suggested that changes in kinematics in total knee arthroplasty (TKA) affected satisfaction level. The aim of this cadaveric study was to evaluate the effect of medial collateral ligament (MCL) release by multiple needle puncture on knee rotational kinematics in posterior-stabilized TKA. Six fresh, frozen cadaveric knees were included in this study. All TKA procedures were performed with an image-free navigation system using a 10-mm polyethylene insert. Tibial internal rotation was assessed to evaluate intraoperative knee kinematics. Multiple needle puncturing was performed 5, 10, and 15 times for the hard portion of the MCL at 90° knee flexion. Kinematic analysis was performed after every 5 punctures. After performing 15 punctures, a 14-mm polyethylene insert was inserted, and kinematic analysis was performed. The tibial internal rotation angle at maximum knee flexion without multiple needle puncturing was significantly larger (9.42°) than that after 15 punctures (3°). Negative correlation (Pearson r = -0.715, P < .001) between tibial internal rotation angle at maximum knee flexion and frequency of puncture was observed. The tibial internal rotation angle with a 14-mm insert was significantly larger (7.25°) compared with the angle after 15 punctures. Tibial internal rotation during knee flexion was reduced by extensive MCL release using multiple needle puncturing and was recovered by increasing of medial tightness. From the point of view of knee kinematics, medial tightness should be allowed to maintain the internal rotation angle of the tibia during knee flexion which might lead to patient satisfaction. Copyright © 2016 Elsevier Inc. All rights reserved.
Meijer, Marrigje F; Velleman, Ton; Boerboom, Alexander L; Bulstra, Sjoerd K; Otten, Egbert; Stevens, Martin; Reininga, Inge H F
2016-01-01
The EOS stereoradiography system has shown to provide reliable varus/valgus (VV) measurements of the lower limb in 2D (VV2D) and 3D (VV3D) after total knee arthroplasty (TKA). Validity of these measurements has not been investigated yet, therefore the purpose of this study was to determine validity of EOS VV2D and VV3D. EOS images were made of a lower limb phantom containing a knee prosthesis, while varying VV angle from 15° varus to 15° valgus and flexion angle from 0° to 20°, and changing rotation from 20° internal to 20° external rotation. Differences between the actual VV position of the lower limb phantom and its position as measured on EOS 2D and 3D images were investigated. Rotation, flexion or VV angle alone had no major impact on VV2D or VV3D. Combination of VV angle and rotation with full extension did not show major differences in VV2D measurements either. Combination of flexion and rotation with a neutral VV angle showed variation of up to 7.4° for VV2D; maximum variation for VV3D was only 1.5°. A combination of the three variables showed an even greater distortion of VV2D, while VV3D stayed relatively constant. Maximum measurement difference between preset VV angle and VV2D was 9.8°, while the difference with VV3D was only 1.9°. The largest differences between the preset VV angle and VV2D were found when installing the leg in extreme angles, for example 15° valgus, 20° flexion and 20° internal rotation. After TKA, EOS VV3D were more valid than VV2D, indicating that 3D measurements compensate for malpositioning during acquisition. Caution is warranted when measuring VV angle on a conventional radiograph of a knee with a flexion contracture, varus or valgus angle and/or rotation of the knee joint during acquisition.
Ogata, Yuta; Anan, Masaya; Takahashi, Makoto; Takeda, Takuya; Tanimoto, Kenji; Sawada, Tomonori; Shinkoda, Koichi
The purpose of this study was to investigate between movement patterns of trunk extension from full unloaded flexion and lifting techniques, which could provide valuable information to physical therapists, doctors of chiropractic, and other manual therapists. A within-participant study design was used. Whole-body kinematic and kinetic data during lifting and full trunk flexion were collected from 16 healthy male participants using a 3-dimensional motion analysis system (Vicon Motion Systems). To evaluate the relationships of joint movement between lifting and full trunk flexion, Pearson correlation coefficients were calculated. There was no significant correlation between the amount of change in the lumbar extension angle during the first half of the lifting trials and lumbar movement during unloaded trunk flexion and extension. However, the amount of change in the lumbar extension angle during lifting was significantly negatively correlated with hip movement during unloaded trunk flexion and extension (P < .05). The findings that the maximum hip flexion angle during full trunk flexion had a greater influence on kinematics of lumbar-hip complex during lifting provides new insight into human movement during lifting. All study participants were healthy men; thus, findings are limited to this group. Copyright © 2018. Published by Elsevier Inc.
Hackney, James; Brummel, Sara; Newman, Mary; Scott, Shannon; Reinagel, Matthew; Smith, Jennifer
2015-09-01
We carried out a study to investigate how low stiffness flooring may help prevent overuse injuries of the lower extremity in dancers. It was hypothesized that performing a ballet jump (sauté) on a reduced stiffness dance floor would decrease maximum joint flexion angles and negative angular velocities at the hips, knees, or ankles compared to performing the same jump on a harder floor. The participants were 15 young adult female dancers (age range 18 to 28, mean = 20.89 ± 2.93 years) with at least 5 years of continuous ballet experience and without history of serious lower body injury, surgery, or recent pain. They performed sautés on a (low stiffness) Harlequin ® WoodSpring Floor and on a vinyl-covered hardwood on concrete floor. Maximum joint flexion angles and negative velocities at bilateral hips, knees, and ankles were measured with the "Ariel Performance Analysis System" (APAS). Paired one-tailed t-tests yielded significant decreases in maximum knee angle (average decrease = 3.4° ± 4.2°, p = 0.026) and angular negative velocity of the ankles (average decrease = 18.7°/sec ± 27.9°/sec, p = 0.009) with low stiffness flooring. If the knee angle is less acute, then the length of the external knee flexion moment arm will also be shorter and result in a smaller external knee flexion moment, given an equal landing force. Also, high velocities of eccentric muscle contraction, which are necessary to control negative angular velocity of the ankle joint, are associated with higher risk of musculotendinous injury. Hence, our findings indicate that reduced floor stiffness may indeed help decrease the likelihood of lower extremity injuries.
Kinematic Patterns Associated with the Vertical Force Produced during the Eggbeater Kick.
Oliveira, Nuno; Chiu, Chuang-Yuan; Sanders, Ross H
2015-01-01
The purpose of this study was to determine the kinematic patterns that maximized the vertical force produced during the water polo eggbeater kick. Twelve water polo players were tested executing the eggbeater kick with the trunk aligned vertically and with the upper limbs above water while trying to maintain as high a position as possible out of the water for nine eggbeater kick cycles. Lower limb joint angular kinematics, pitch angles and speed of the feet were calculated. The vertical force produced during the eggbeater kick cycle was calculated using inverse dynamics for the independent lower body segments and combined upper body segments, and a participant-specific second-degree regression equation for the weight and buoyancy contributions. Vertical force normalized to body weight was associated with hip flexion (average, r = 0.691; maximum, r = 0.791; range of motion, r = 0.710), hip abduction (maximum, r = 0.654), knee flexion (average, r = 0.716; minimum, r = 0.653) and knee flexion-extension angular velocity (r = 0.758). Effective orientation of the hips resulted in fast horizontal motion of the feet with positive pitch angles. Vertical motion of the feet was negatively associated with vertical force. A multiple regression model comprising the non-collinear variables of maximum hip abduction, hip flexion range of motion and knee flexion angular velocity accounted for 81% of the variance in normalized vertical force. For high performance in the water polo, eggbeater kick players should execute fast horizontal motion with the feet by having large abduction and flexion of the hips, and fast extension and flexion of the knees.
Park, Kwan Kyu; Hosseini, Ali; Tsai, Tsung-Yuan; Kwon, Young-Min; Li, Guoan
2015-02-05
The mechanisms that affect knee flexion after total knee arthroplasty (TKA) are still debatable. This study investigated the elongation of the superficial medial (sMCL) and lateral collateral ligaments (LCL) before and after a posterior cruciate retaining (CR) TKA. We hypothesized that overstretching of the collateral ligaments in high flexion after TKA could reduce maximal flexion of the knee. Three-dimensional models of 11 osteoarthritic knees of 11 patients including the insertions of the collateral ligaments were created using MR images. Each ligament was divided into three equal portions: anterior, middle and posterior portions. The shortest 3D wrapping length of each ligament portion was determined before and after the TKA surgery along a weight-bearing, single leg flexion path. The relationship between the changes of ligament elongation and the changes of the maximal knee flexion after TKAs was quantitatively analyzed. The sMCL showed significant increases in length only at low flexion after TKA; the LCL showed decreases in length at full extension, but increases with further flexion after TKA. The amount of increases of the maximum flexion angle after TKA was negatively correlated with the increases of the elongations of the anterior portion (p=0.010, r=0.733) and middle portion (p=0.049, r=0.604) of the sMCL as well as the anterior portion (p=0.010, r=0.733) of the LCL at maximal flexion of the knee. The results indicated that the increases of the length of the collateral ligaments at maximal flexion after TKA were associated with the decreases of the maximal flexion of the knee. Our data suggest that collateral ligament management should also be evaluated at higher knee flexion angles in order to optimize maximal flexion of the knee after TKAs. Copyright © 2014 Elsevier Ltd. All rights reserved.
Seitz, Andreas Martin; Lubomierski, Anja; Friemert, Benedikt; Ignatius, Anita; Dürselen, Lutz
2012-06-01
We examined the influence of partial meniscectomy of 10 mm width on 10 human cadaveric knee joints, as it is performed during the treatment of radial tears in the posterior horn of the medial meniscus, on maximum contact pressure, contact area (CA), and meniscal hoop strain in the lateral and medial knee compartments. In case of 0° and 30° flexion angle, 20% and 50% partial meniscectomy did not influence maximum contact pressure and area. Only in case of 60° knee flexion, 50% partial resection increased medial maximum contact pressure and decreased the medial CA statistically significant. However, 100% partial resection increased maximum contact pressure and decreased CA significantly in the meniscectomized medial knee compartment in all tested knee positions. No significant differences were noted for meniscal hoop strain. From a biomechanical point of view, our in vitro study suggests that the medial joint compartment is not in danger of accelerated cartilage degeneration up to a resection limit of 20% meniscal depth and 10 mm width. Contact mechanics are likely to be more sensitive to partial meniscectomy at higher flexion angles, which has to be further investigated. Copyright © 2011 Orthopaedic Research Society.
Murray, Amanda M; Thomas, Abbey C; Armstrong, Charles W; Pietrosimone, Brian G; Tevald, Michael A
2015-12-01
Abnormal knee joint mechanics have been implicated in the pathogenesis and progression of knee osteoarthritis. Deficits in muscle function (i.e., strength and power) may contribute to abnormal knee joint loading. The associations between quadriceps strength, power and knee joint mechanics remain unclear in knee osteoarthritis. Three-dimensional motion analysis was used to collect peak knee joint angles and moments during the first 50% of stance phase of gait in 33 participants with knee osteoarthritis. Quadriceps strength and power were assessed using a knee extension machine. Strength was quantified as the one repetition maximum. Power was quantified as the peak power produced at 40-90% of the one repetition maximum. Quadriceps strength accounted for 15% of the variance in peak knee flexion angle (P=0.016). Quadriceps power accounted for 20-29% of the variance in peak knee flexion angle (P<0.05). Quadriceps power at 90% of one repetition maximum accounted for 9% of the variance in peak knee adduction moment (P=0.05). These data suggest that quadriceps power explains more variance in knee flexion angle and knee adduction moment during gait in knee osteoarthritis than quadriceps strength. Additionally, quadriceps power at multiple loads is associated with knee joint mechanics and therefore should be assessed at a variety of loads. Taken together, these results indicate that quadriceps power may be a potential target for interventions aimed at changing knee joint mechanics in knee osteoarthritis. Copyright © 2015 Elsevier Ltd. All rights reserved.
Cao, Wujing; Yu, Hongliu; Zhao, Weiliang; Meng, Qiaoling; Chen, Wenming
2018-04-20
The microprocessor-controlled prosthetic knees have been introduced to transfemoral amputees due to advances in biomedical engineering. A body of scientific literature has shown that the microprocessor-controlled prosthetic knees improve the gait and functional abilities of persons with transfemoral amputation. The aim of this study was to propose a new microprocessor-controlled prosthetic knee (MPK) and compare it with non-microprocessor-controlled prosthetic knees (NMPKs) under different walking speeds. The microprocessor-controlled prosthetic knee (i-KNEE) with hydraulic damper was developed. The comfortable self-selected walking speeds of 12 subjects with i-KNEE and NMPK were obtained. The maximum swing flexion knee angle and gait symmetry were compared in i-KNEE and NMPK condition. The comfortable self-selected walking speeds of some subjects were higher with i-KNEE while some were not. There was no significant difference in comfortable self-selected walking speed between the i-KNEE and the NMPK condition (P= 0.138). The peak prosthetic knee flexion during swing in the i-KNEE condition was between sixty and seventy degree under any walking speed. In the NMPK condition, the maximum swing flexion knee angle changed significantly. And it increased with walking speed. There is no significant difference in knee kinematic symmetry when the subjects wear the i-KNEE or NMPK. The results of this study indicated that the new microprocessor-controlled prosthetic knee was suitable for transfemoral amputees. The maximum swing flexion knee angle under different walking speeds showed different properties in the NMPK and i-KNEE condition. The i-KNEE was more adaptive to speed changes. There was little difference of comfortable self-selected walking speed between i-KNEE and NMPK condition.
The Effects of Fatigue and Local Carriage on Musculoskeletal Injury Mechanisms
2012-09-01
the mean and SD of the pelvis, hip, knee , and ankle angles at heel contact and stance of walking. Table 5 shows the mean and SD of the hip, knee , and...22.9 (8.6) Hip flexion at heel contact (deg) 32.1 (4.3) 28.2 (10.4) 45.4 (5.2) 40.6 (10.9) Knee flexion at heel contact (deg) -2.5 (3.1...1.1 (4.5) 3.9 (3.2) 4.7 (4.9) Maximum knee flexion at stance (deg) 19.0 (2.8) 20.7 (4.4) 24.6 (4.5) 25.0 (5.3) Ankle dorsi-flexion at heel
Schreurs, Mervin J; Benjaminse, Anne; Lemmink, Koen A P M
2017-10-03
Cutting is an important skill in team-sports, but unfortunately is also related to non-contact ACL injuries. The purpose was to examine knee kinetics and kinematics at different cutting angles. 13 males and 16 females performed cuts at different angles (45°, 90°, 135° and 180°) at maximum speed. 3D kinematics and kinetics were collected. To determine differences across cutting angles (45°, 90°, 135° and 180°) and sex (female, male), a 4×2 repeated measures ANOVA was conducted followed by post hoc comparisons (Bonferroni) with alpha level set at α≤0.05a priori. At all cutting angles, males showed greater knee flexion angles than females (p<0.01). Also, where males performed all cutting angles with no differences in the amount of knee flexion -42.53°±8.95°, females decreased their knee flexion angle from -40.6°±7.2° when cutting at 45° to -36.81°±9.10° when cutting at 90°, 135° and 180° (p<0.01). Knee flexion moment decreased for both sexes when cutting towards sharper angles (p<0.05). At 90°, 135° and 180°, males showed greater knee valgus moments than females. For both sexes, knee valgus moment increased towards the sharper cutting angles and then stabilized compared to the 45° cutting angle (p<0.01). Both females and males showed smaller vGRF when cutting to sharper angles (p<0.01). It can be concluded that different cutting angles demand different knee kinematics and kinetics. Sharper cutting angles place the knee more at risk. However, females and males handle this differently, which has implications for injury prevention. Copyright © 2017 Elsevier Ltd. All rights reserved.
Elbow kinematics during sit-to-stand and stand-to-sit movements.
Packer, T L; Wyss, U P; Costigan, P A
1993-11-01
The sit-to-stand and stand-to-sit movements of 10 healthy women (mean age 52.4 years) were subjected to a descriptive analysis that yielded a definition of phases, determination of the peak angles reached, maximum angular velocity during each movement, and the sequencing of key events. While subjects showed little intrasubject variability, intersubject variability was evident. Subjects differed in the joint angles and angular velocity recorded, but the sequence of flexion/extension and rotation events were unchanged. Changes in direction of flexion/extension and rotation tended to occur very close in time, if not at the same time. Copyright © 1993. Published by Elsevier Ltd.
Fisher, Harry; Stephenson, Mitchell L; Graves, Kyle K; Hinshaw, Taylour J; Smith, Derek T; Zhu, Qin; Wilson, Margaret A; Dai, Boyi
2016-06-01
Decreased knee flexion angles during landing are associated with increased anterior cruciate ligament loading. The underlying mechanisms associated with decreased self-selected knee flexion angles during landing are still unclear. The purpose of this study was to establish the relationship between the peak force production at various knee flexion angles (35, 55, 70, and 90°) during isometric squats and the actual knee flexion angles that occur during landing in both men and women. A total of 18 men and 18 women recreational/collegiate athletes performed 4 isometric squats at various knee flexion angles while vertical ground reaction forces were recorded. Participants also performed a jump-landing-jump task while lower extremity kinematics were collected. For women, significant correlations were found between the peak force production at 55 and 70° of knee flexion during isometric squats and the knee flexion angle at initial contact of landing. There were also significant correlations between the peak force production at 55, 70, and 90° of knee flexion during isometric squats and the peak knee flexion angle during landing. These correlations tended to be stronger during isometric squats at greater knee flexion compared with smaller knee flexion. No significant correlations were found for men. Posture-specific strength may play an important role in determining self-selected knee flexion angles during landing for women.
Acute Lower Extremity Running Kinematics After a Hamstring Stretch
Davis Hammonds, Autumn L.; Laudner, Kevin G.; McCaw, Steve; McLoda, Todd A.
2012-01-01
Context: Limited passive hamstring flexibility might affect kinematics, performance, and injury risk during running. Pre-activity static straight-leg raise stretching often is used to gain passive hamstring flexibility. Objective: To investigate the acute effects of a single session of passive hamstring stretching on pelvic, hip, and knee kinematics during the swing phase of running. Design: Randomized controlled clinical trial. Setting: Biomechanics research laboratory. Patients or Other Participants: Thirty-four male (age = 21.2 ± 1.4 years) and female (age = 21.3±2.0 years) recreational athletes. Intervention(s): Participants performed treadmill running pretests and posttests at 70% of their age-predicted maximum heart rate. Pelvis, hip, and knee joint angles during the swing phase of 5 consecutive gait cycles were collected using a motion analysis system. Right and left hamstrings of the intervention group participants were passively stretched 3 times for 30 seconds in random order immediately after the pretest. Control group participants performed no stretching or movement between running sessions. Main Outcome Measure(s): Six 2-way analyses of variance to determine joint angle differences between groups at maximum hip flexion and maximum knee extension with an α level of .008. Results: Flexibility increased between pretest and post-test in all participants (F1,30 = 80.61, P<.001). Anterior pelvic tilt (F1,30 = 0.73, P=.40), hip flexion (F1,30 = 2.44, P=.13), and knee extension (F1,30 = 0.06, P=.80) at maximum hip flexion were similar between groups throughout testing. Anterior pelvic tilt (F1,30 = 0.69, P=.41), hip flexion (F1,30 = 0.23, P=.64), and knee extension (F1,30 = 3.38, P=.62) at maximum knee extension were similar between groups throughout testing. Men demonstrated greater anterior pelvic tilt than women at maximum knee extension (F1,30 = 13.62, P=.001). Conclusions: A single session of 3 straight-leg raise hamstring stretches did not change pelvis, hip, or knee running kinematics. PMID:22488225
Sosdian, L; Dobson, F; Wrigley, T V; Paterson, K; Bennell, K; Dowsey, M; Choong, P; Allison, K; Hinman, R S
2014-12-01
Knee arthroplasty (KA) is recognized as an effective treatment of knee joint osteoarthritis and up to 90% of patients experience substantial pain relief. There has been no systematic review synthesizing the longitudinal changes in gait following KA. The aims of this systematic review were to determine the effects of KA on (i) frontal plane and (ii) sagittal plane kinematic and kinetic parameters during the stance phase of gait. MEDLINE (PubMed), CINAHL, SPORTdiscus (EBSCO), and Cochrane Library (Wiley) were searched until April 10th, 2014. 1,765 articles were identified, of which 19 studies describing 3-dimensional gait analysis pre- and post-KA were included. Study quality was evaluated by two reviewers independently using the Downs and Black checklist. Following KA, in the frontal plane, the maximum knee adduction angle and external knee adduction moment (KAM) tended to decrease. In the sagittal plane, findings suggest that the maximum knee flexion moment is increased. From the ten studies that included a healthy reference group, it was unclear whether gait variables returned to normal following KA. Overall, it appears that KA results in a decreased peak KAM and maximum knee adduction angles, an increased peak knee flexion moment and inconsistent changes in the peak knee flexion angle. Knowledge gaps remain due to methodological inconsistencies across studies, limited statistical analysis, and largely heterogeneous sample populations. More research is needed to determine whether KA restores gait patterns to normal, or if additional rehabilitation may be needed to optimize gait following surgery for osteoarthritis. Copyright © 2014 Elsevier B.V. All rights reserved.
Mid-term Results of Total Knee Arthroplasty Using PFC Sigma RP-F.
Kim, Jun-Young; Cheon, Sang-Ho; Kyung, Hee-Soo
2012-12-01
We compared the mid-term results after total knee arthroplasty (TKA) using PFC Sigma RP-F mobile model with PFC Sigma PS fixed model. We analyzed 45 knees that underwent TKA with PFC Sigma RP-Fn (study group) and 45 knees with PFC Sigma PS (control group). The mean follow-up period was 65 months (range, 60-69 months). The evaluation system of the American knee society was used for clinical and radiological assessment. Also, the maximal knee flexion angle was assessed. The mean maximum flexion angle in the study group (135°) was greater than that in the control group (125°) at the early post-operation & final follow-up period (p=0.033). The range of motion (ROM) in the study group was recovered earlier at the postoperative 6 months, and ROM gain was improved to a greater extent at the final follow-up period (p=0.039). The knee score and function score and radiographic evaluation were no difference between the two groups (p>0.05) at the final follow-up. The two cases of radiolucency in posterior condyle and medial tibial plateau and one case of patellar elongation were seen in the study group. The PFC Sigma RP-F mobile system appears to facilitate greater maximum flexion angle and ROM gain with two cases of radiolucent line.
[Clinical significance of Q-angle under different conditions in recurrent patellar dislocation].
Wang, Zhijie; Chen, You; Li, Anping; Long, Yi
2014-01-01
To investigate the clinical significance of Q-angle measuring under different conditions in female recurrent patellar dislocation female patients. Between August 2012 and March 2013, 10 female patients (11 knees) with recurrent patellar dislocation were collected as trial group; 20 female patients (20 knees) with simple meniscus injury were collected as control group at the same time. Q-angle was measured in extension, 30 degrees flexion, 30 degrees flexion with manual correction, and surgical correction in the trial group, and only in extension and 30 degrees flexion in the control group. Then the difference value of Q-angle between extension and 30 degrees flexion (Q-angle in extension subtracts Q-angle in 30 flexion) were calculated. Independent sample t-test was used to analyze Q-angle degrees in extension, 30 degrees flexion, and the changed degrees of 2 groups. The Q-angle between manual correction and surgical correction of the trial group was analyzed by paired t-test. The Q-angle in extension, Q-angle in 30 degrees flexion, and difference value of Q-angle between extension and 30 degrees flexion were (17.2 +/- 3.6), (14.3 +/- 3.0), and (2.9 +/- 1.9) degrees in the trial group and were (15.2 +/- 3.4), (14.4 +/- 3.5), and (0.8 +/- 1.7) degrees in the control group. No significant difference was found in Q-angle of extension or Q-angle of 30 degrees flexion between 2 groups (P > 0.05), but the difference value of Q-angle between extension and 30 degrees flexion in the trial group was significantly larger than that in the control group (t = 3.253, P = 0.003). The Q-angle in 30 degrees flexion with manual correction and surgical correction in the trial group was (19.8 +/- 3.4) degrees and (18.9 +/- 3.8) degrees respectively, showing no significant difference (t = 2.193, P = 0.053). When a female patient's Q-angle in 30 degrees flexion knee changes obviously compared with Q-angle in extension position, recurrent patellar dislocation should be considered. For female patients with recurrent patellar dislocation, the preoperative Q-angle in 30 degrees flexion with manual correction should be measured, which can help increasing the accuracy of evaluation whether rearrangement should be performed.
Louw, Maryke; Deary, Clare
2014-02-01
The aim of this literature review was to identify the biomechanical variables involved in the aetiology of iliotibial band syndrome (ITBS) in distance runners. An electronic search was conducted using the terms "iliotibial band" and "iliotibial tract". The results showed that runners with a history of ITBS appear to display decreased rear foot eversion, tibial internal rotation and hip adduction angles at heel strike while having greater maximum internal rotation angles at the knee and decreased total abduction and adduction range of motion at the hip during stance phase. They further appear to experience greater invertor moments at their feet, decreased abduction and flexion velocities at their hips and to reach maximum hip flexion angles earlier than healthy controls. Maximum normalised braking forces seem to be decreased in these athletes. The literature is inconclusive with regards to muscle strength deficits in runners with a history of ITBS. Prospective research suggested that greater internal rotation at the knee joint and increased adduction angles of the hip may play a role in the aetiology of ITBS and that the strain rate in the iliotibial bands of these runners may be increased compared to healthy controls. A clear biomechanical cause for ITBS could not be devised due to the lack of prospective research. Copyright © 2013 Elsevier Ltd. All rights reserved.
Nakano, Naoki; Matsumoto, Tomoyuki; Muratsu, Hirotsugu; Takayama, Koji; Kuroda, Ryosuke; Kurosaka, Masahiro
2016-02-01
Although many studies have reported that postoperative knee flexion is influenced by preoperative conditions, the factors which affect postoperative knee flexion have not been fully elucidated. We tried to investigate the influence of intraoperative soft tissue balance on postoperative knee flexion angle after cruciate-retaining (CR) total knee arthroplasty (TKA) using a navigation and an offset-type tensor. We retrospectively analyzed 55 patients with osteoarthritis who underwent TKA using e.motion-CR (B. Braun Aesculap, Germany) whose knee flexion angle could be measured at 2 years after operation. The exclusion criteria included valgus deformity, severe bony defect, infection, and bilateral TKA. Intraoperative varus ligament balance and joint component gap were measured with the navigation (Orthopilot 4.2; B. Braun Aesculap) while applying 40-lb joint distraction force at 0° to 120° of knee flexion using an offset-type tensor. Correlations between the soft tissue parameters and postoperative knee flexion angle were analyzed using simple linear regression models. Varus ligament balance at 90° of flexion (R = 0.56; P < .001) and lateral compartment gap at 90° of flexion (R = 0.51; P < .001) were positively correlated with postoperative knee flexion angle. In addition, as with past studies, joint component gap at 90° of flexion (R = 0.30; P < .05) and preoperative knee flexion angle (R = 0.63; P < .001) were correlated with postoperative knee flexion angle. Lateral laxity as well as joint component gap at 90° of flexion is one of the most important factors affecting postoperative knee flexion angle in CR-TKA. Copyright © 2016 Elsevier Inc. All rights reserved.
Hackett, Lucien; Reed, Darren; Halaki, Mark; Ginn, Karen A
2014-04-01
No direct evidence exists to support the validity of using surface electrodes to record muscle activity from serratus anterior, an important and commonly investigated shoulder muscle. The aims of this study were to determine the validity of examining muscle activation patterns in serratus anterior using surface electromyography and to determine whether intramuscular electromyography is representative of serratus anterior muscle activity. Seven asymptomatic subjects performed dynamic and isometric shoulder flexion, extension, abduction, adduction and dynamic bench press plus tests. Surface electrodes were placed over serratus anterior and around intramuscular electrodes in serratus anterior. Load was ramped during isometric tests from 0% to 100% maximum load and dynamic tests were performed at 70% maximum load. EMG signals were normalised using five standard maximum voluntary contraction tests. Surface electrodes significantly underestimated serratus anterior muscle activity compared with the intramuscular electrodes during dynamic flexion, dynamic abduction, isometric flexion, isometric abduction and bench press plus tests. All other test conditions showed no significant differences including the flexion normalisation test where maximum activation was recorded from both electrode types. Low correlation between signals was recorded using surface and intramuscular electrodes during concentric phases of dynamic abduction and flexion. It is not valid to use surface electromyography to assess muscle activation levels in serratus anterior during isometric exercises where the electrodes are not placed at the angle of testing and dynamic exercises. Intramuscular electrodes are as representative of the serratus anterior muscle activity as surface electrodes. Copyright © 2014 Elsevier Ltd. All rights reserved.
A Highly Backdrivable, Lightweight Knee Actuator for Investigating Gait in Stroke
Sulzer, James S.; Roiz, Ronald A.; Peshkin, Michael A.; Patton, James L.
2012-01-01
Many of those who survive a stroke develop a gait disability known as stiff-knee gait (SKG). Characterized by reduced knee flexion angle during swing, people with SKG walk with poor energy efficiency and asymmetry due to the compensatory mechanisms required to clear the foot. Previous modeling studies have shown that knee flexion activity directly before the foot leaves the ground, and this should result in improved knee flexion angle during swing. The goal of this research is to physically test this hypothesis using robotic intervention. We developed a device that is capable of assisting knee flexion torque before swing but feels imperceptible (transparent) for the rest of the gait cycle. This device uses sheathed Bowden cable to control the deflection of a compliant torsional spring in a configuration known as a Series Elastic Remote Knee Actuator (SERKA). In this investigation, we describe the design and evaluation of SERKA, which includes a pilot experiment on stroke subjects. SERKA could supply a substantial torque (12 N· m) in less than 20 ms, with a maximum torque of 41 N·m. The device resisted knee flexion imperceptibly when desired, at less than 1 N·m rms torque during normal gait. With the remote location of the actuator, the user experiences a mass of only 1.2 kg on the knee. We found that the device was capable of increasing both peak knee flexion angle and velocity during gait in stroke subjects. Thus, the SERKA is a valid experimental device that selectively alters knee kinetics and kinematics in gait after stroke. PMID:22563305
Song, Young Dong; Jain, Nimash; Kang, Yeon Gwi; Kim, Tae Yune; Kim, Tae Kyun
2016-06-01
Correlations between maximum flexion and functional outcomes in total knee arthroplasty (TKA) patients are reportedly weak. We investigated whether there are differences between passive maximum flexion in nonweight bearing and other types of maximum flexion and whether the type of maximum flexion correlates with functional outcomes. A total of 210 patients (359 knees) underwent preoperative evaluation and postoperative follow-up evaluations (6, 12, and 24 months) for the assessment of clinical outcomes including maximum knee flexion. Maximum flexion was measured under five conditions: passive nonweight bearing, passive weight bearing, active nonweight bearing, and active weight bearing with or without arm support. Data were analyzed for relationships between passive maximum flexion in nonweight bearing by Pearson correlation analyses, and a variance comparison between measurement techniques via paired t test. We observed substantial differences between passive maximum flexion in nonweight bearing and the other four maximum flexion types. At all time points, passive maximum flexion in nonweight bearing correlated poorly with active maximum flexion in weight bearing with or without arm support. Active maximum flexion in weight bearing better correlated with functional outcomes than the other maximum flexion types. Our study suggests active maximum flexion in weight bearing should be reported together with passive maximum flexion in nonweight bearing in research on the knee motion arc after TKA.
Song, Young Dong; Jain, Nimash; Kang, Yeon Gwi; Kim, Tae Yune
2016-01-01
Purpose Correlations between maximum flexion and functional outcomes in total knee arthroplasty (TKA) patients are reportedly weak. We investigated whether there are differences between passive maximum flexion in nonweight bearing and other types of maximum flexion and whether the type of maximum flexion correlates with functional outcomes. Materials and Methods A total of 210 patients (359 knees) underwent preoperative evaluation and postoperative follow-up evaluations (6, 12, and 24 months) for the assessment of clinical outcomes including maximum knee flexion. Maximum flexion was measured under five conditions: passive nonweight bearing, passive weight bearing, active nonweight bearing, and active weight bearing with or without arm support. Data were analyzed for relationships between passive maximum flexion in nonweight bearing by Pearson correlation analyses, and a variance comparison between measurement techniques via paired t test. Results We observed substantial differences between passive maximum flexion in nonweight bearing and the other four maximum flexion types. At all time points, passive maximum flexion in nonweight bearing correlated poorly with active maximum flexion in weight bearing with or without arm support. Active maximum flexion in weight bearing better correlated with functional outcomes than the other maximum flexion types. Conclusions Our study suggests active maximum flexion in weight bearing should be reported together with passive maximum flexion in nonweight bearing in research on the knee motion arc after TKA. PMID:27274468
Wallace, B J; Kernozek, T W; Bothwell, E C
2007-12-01
Females experience at least twice as many non-contact anterior cruciate ligament (ACL) injuries as males. The aim of this study was to investigate if males and females exhibited different characteristics while performing a modified pro-agility test. Collegiate Division III male baseball (n=14) and female softball (n=13) players performed 4 trials of a modified pro-agility task, which consisted of running toward a force platform target for 5 steps, planting their right foot, and propelling themselves off of the target with their left foot. Kinematic and kinetic parameters were compared using a multivariate analysis of variance between gender with the level of significance set at P<0.05. Males and females exhibited similar knee valgus angles. Females had a greater maximum knee extension angle (10.14 degrees vs 17.43 degrees ), and greater knee range of motion (46.12 degrees vs 40.12 degrees ). Both groups reached maximum knee flexion at 52% of stance. Females had significantly more maximum hip flexion than males (28.86 degrees vs 22.75 degrees ). Females had significantly smaller minimum internal knee varus moments than their male counterparts (1.12 Nm/kg vs 1.55 Nm/kg). Vertical ground reaction forces as a percentage of bodyweight, and stance time, were not statistically different. The female group displayed an external knee rotation angle (2.49 degrees ) during the beginning of their stance, which was significantly different than the internal rotation angle (4.11 degrees ) in the male group. Early in stance knee rotation angle was highly correlated with the lack of internal knee varus moment (males R(2)=0.75, females R(2)=0.88). Females displayed knee moments and kinematics that may place them at greater risk for ACL injury during a stop-cut task. Females should be coached to perform stop cuts with more knee flexion and a more neutral knee rotation angle upon foot contact in an effort to reduce moments that may place the ACL at risk.
Oh, Won Seok; Lee, Yong Seuk; Kim, Byung Kak; Sim, Jae Ang; Lee, Beom Koo
2016-06-01
To analyze the contact mechanics of the femoral component and polyethylene of the Low Contact Stress rotating platform (LCS-RP) in nonweight bearing and weight bearing conditions using full flexion lateral radiographs. From May 2009 to December 2013, 58 knees in 41 patients diagnosed with osteoarthritis and treated with total knee arthroplasty (TKA) were included in this study. TKA was performed using an LCS-RP knee prosthesis. Full flexion lateral radiographs in both weight bearing and nonweight bearing condition were taken at least one month postoperatively (average, 28.8 months). Translation of femoral component was determined by the contact point between the femoral component and polyethylene. Maximum flexion was measured as the angle between the lines drawn at the midpoint of the femur and tibia. Posterior shift of the contact point in LCS-RP TKA was observed under weight bearing condition, which resulted in deeper flexion compared to LCS-RP TKA under nonweight bearing condition. In the LCS-RP TKA, the contact point between the femoral component and polyethylene moved posteriorly under weight bearing condition, and the joint was more congruent and maximum flexion increased with weight bearing.
Fujimoto, Eisaku; Sasashige, Yoshiaki; Masuda, Yasuji; Hisatome, Takashi; Eguchi, Akio; Masuda, Tetsuo; Sawa, Mikiya; Nagata, Yoshinori
2013-12-01
The intra-operative femorotibial joint gap and ligament balance, the predictors affecting these gaps and their balances, as well as the postoperative knee flexion, were examined. These factors were assessed radiographically after a posterior cruciate-retaining total knee arthroplasty (TKA). The posterior condylar offset and posterior tibial slope have been reported as the most important intra-operative factors affecting cruciate-retaining-type TKAs. The joint gap and balance have not been investigated in assessments of the posterior condylar offset and the posterior tibial slope. The femorotibial gap and medial/lateral ligament balance were measured with an offset-type tensor. The femorotibial gaps were measured at 0°, 45°, 90° and 135° of knee flexion, and various gap changes were calculated at 0°-90° and 0°-135°. Cruciate-retaining-type arthroplasties were performed in 98 knees with varus osteoarthritis. The 0°-90° femorotibial gap change was strongly affected by the posterior condylar offset value (postoperative posterior condylar offset subtracted by the preoperative posterior condylar offset). The 0°-135° femorotibial gap change was significantly correlated with the posterior tibial slope and the 135° medial/lateral ligament balance. The postoperative flexion angle was positively correlated with the preoperative flexion angle, γ angle and the posterior tibial slope. Multiple-regression analysis demonstrated that the preoperative flexion angle, γ angle, posterior tibial slope and 90° medial/lateral ligament balance were significant independent factors for the postoperative knee flexion angle. The flexion angle change (postoperative flexion angle subtracted by the preoperative flexion angle) was also strongly correlated with the preoperative flexion angle, posterior tibial slope and 90° medial/lateral ligament balance. The postoperative flexion angle is affected by multiple factors, especially in cruciate-retaining-type TKAs. However, it is important to pay attention not only to the posterior tibial slope, but also to the flexion medial/lateral ligament balance during surgery. A cruciate-retaining-type TKA has the potential to achieve both stability and a wide range of motion and to improve the patients' activities of daily living.
Shyr, Tien-Wei; Shie, Jing-Wen; Jiang, Chang-Han; Li, Jung-Jen
2014-01-01
In this work a wearable gesture sensing device consisting of a textile strain sensor, using elastic conductive webbing, was designed for monitoring the flexion angle of elbow and knee movements. The elastic conductive webbing shows a linear response of resistance to the flexion angle. The wearable gesture sensing device was calibrated and then the flexion angle-resistance equation was established using an assembled gesture sensing apparatus with a variable resistor and a protractor. The proposed device successfully monitored the flexion angle during elbow and knee movements. PMID:24577526
Neck muscle fatigue alters the cervical flexion relaxation ratio in sub-clinical neck pain patients.
Zabihhosseinian, Mahboobeh; Holmes, Michael W R; Ferguson, Brad; Murphy, Bernadette
2015-06-01
The cervical flexion relaxation ratio is lower in neck pain patients compared to healthy controls. Fatigue modulates the onset and offset angles of the silent period in both the lumbar and cervical spine in healthy individuals; however, this response has not been studied with neck pain patients. The purpose of this study was to determine if cervical extensor fatigue would alter the parameters of the cervical flexion relaxation more in a neck pain group than a healthy control group. Thirteen healthy and twelve neck pain patients participated. Cervical extensor activity was examined bilaterally and kinematics of the neck and head were collected. An isometric, repetitive neck extension task at 70% of maximum elicited fatigue. Participants performed 3 trials of maximal cervical flexion both pre and post fatigue. The healthy controls and neck pain groups fatigued after 56 (41) and 39 (31) repetitions, respectively. There was a significant interaction effect for the flexion relaxation ratio between the control and neck pain groups from pre to post fatigue trials (F1,96=22.67, P=0.0001), but not for onset and offset angles (F1, 96=0.017, P=0.897), although the onset and offset angles did decrease significantly for both groups following fatigue (F1,96=9.26, P=0.002). Individuals with mild to moderate neck pain have significant differences in their neuromuscular control relative to controls, experienced myoelectric fatigue with fewer repetitions in a shorter time, had a lower cervical flexion relaxation ratio at baseline and had an inability to decrease this ratio further in response to fatigue. Copyright © 2015 Elsevier Ltd. All rights reserved.
Shi, Kenrin; Hayashida, Kenji; Umeda, Naoya; Yamamoto, Kengo; Kawai, Hideo
2008-02-01
Femoral component rollback and tibial rotation were evaluated using lateral radiographs taken during passive knee flexion under fluoroscopy in NexGen Legacy Posterior Stabilized Flex (Zimmer, Warsaw, Ind) total knee arthroplasties (TKAs; 30 with mobile insert and 26 with fixed insert). Measured maximal flexion angle demonstrated no significant differences. Femoral component rollback was observed predominantly in TKAs with fixed insert in more than 45 degrees flexion and correlated with maximal flexion angle in each group. Tibial internal rotation was more significant in TKAs with mobile insert in maximal flexion. However, tibial internal rotation from 90 degrees to maximal flexion, which demonstrated correlation with maximal flexion angle in each group, did not show significant difference. The kinematic differences between 2 inserts seemed to have little relevance to the maximal flexion angle.
Kubota, So; Inaba, Yutaka; Kobayashi, Naomi; Choe, Hyonmin; Tezuka, Taro; Saito, Tomoyuki
2017-10-16
While cam resection is essential to achieve a good clinical result with respect to femoroacetabular impingement (FAI), it is unclear whether it should also be performed in cases of borderline developmental dysplasia of the hip (DDH) with a cam deformity. The aim of this study was to evaluate improvements in range of motion (ROM) in cases of cam-type FAI and borderline DDH after virtual osteochondroplasty using a computer impingement simulation. Thirty-eight symptomatic hips in 31 patients (11male and 20 female) diagnosed with cam-type FAI or borderline DDH were analyzed. There were divided into a cam-type FAI group (cam-FAI group: 15 hips), borderline DDH without cam group (DDH W/O cam group: 12 hips), and borderline DDH with cam group (DDH W/ cam group: 11 hips). The bony impingement point on the femoral head-neck junction at 90° flexion and maximum internal rotation of the hip joint was identified using ZedHip® software. Virtual osteochondroplasty of the impingement point was then performed in all cases. The maximum flexion angle and maximum internal rotation angle at 90° flexion were measured before and after virtual osteochondroplasty at two resection ranges (i.e., slight and sufficient). The mean improvement in the internal rotation angle in the DDH W/ cam group after slight resection was significantly greater than that in the DDH W/O cam group (P = 0.046). Furthermore, the mean improvement in the internal rotation angle in the DDH W/ cam and cam-FAI groups after sufficient resection was significantly greater than that in the DDH W/O cam group (DDH W/ cam vs DDH W/O cam: P = 0.002, cam-FAI vs DDH W/O cam: P = 0.043). Virtual osteochondroplasty resulted in a significant improvement in internal rotation angle in DDH W/ cam group but not in DDH W/O cam group. Thus, borderline DDH cases with cam deformity may be better to consider performing osteochondroplasty.
Hahn, Daniel; Herzog, Walter; Schwirtz, Ansgar
2014-08-01
Force and torque production of human muscles depends upon their lengths and contraction velocity. However, these factors are widely assumed to be independent of each other and the few studies that dealt with interactions of torque, angle and angular velocity are based on isolated single-joint movements. Thus, the purpose of this study was to determine force/torque-angle and force/torque-angular velocity properties for multi-joint leg extensions. Human leg extension was investigated (n = 18) on a motor-driven leg press dynamometer while measuring external reaction forces at the feet. Extensor torque in the knee joint was calculated using inverse dynamics. Isometric contractions were performed at eight joint angle configurations of the lower limb corresponding to increments of 10° at the knee from 30 to 100° of knee flexion. Concentric and eccentric contractions were performed over the same range of motion at mean angular velocities of the knee from 30 to 240° s(-1). For contractions of increasing velocity, optimum knee angle shifted from 52 ± 7 to 64 ± 4° knee flexion. Furthermore, the curvature of the concentric force/torque-angular velocity relations varied with joint angles and maximum angular velocities increased from 866 ± 79 to 1,238 ± 132° s(-1) for 90-50° knee flexion. Normalised eccentric forces/torques ranged from 0.85 ± 0.12 to 1.32 ± 0.16 of their isometric reference, only showing significant increases above isometric and an effect of angular velocity for joint angles greater than optimum knee angle. The findings reveal that force/torque production during multi-joint leg extension depends on the combined effects of angle and angular velocity. This finding should be accounted for in modelling and optimisation of human movement.
Tsukada, Sachiyuki; Fujii, Tomoko; Wakui, Motohiro
2017-08-01
This study was performed to assess the impact of soft tissue imbalance on the knee flexion angle 2 years after posterior stabilized total knee arthroplasty (TKA). A total of 329 consecutive varus knees were included to assess the association of knee flexion angle 2 years after TKA with preoperative, intraoperative, and postoperative variables. All intraoperative soft tissue measurements were performed by a single surgeon under spinal anesthesia in a standardized manner including the subvastus approach, reduced patella, and without use of a pneumonic tourniquet. Multiple linear regression analysis showed no significant correlations in terms of intraoperative valgus imbalance at 90-degree flexion or the difference in soft tissue tension between 90-degree flexion and 0-degree extension (β = -0.039; 95% confidence interval [CI], -0.88 to 0.80; P = .93 and β = 0.015; 95% CI, -0.29 to 0.32; P = .92, respectively). Preoperative flexion angle was significantly correlated with knee flexion angle 2 years after TKA (β = 0.42; 95% CI, 0.33 to 0.51; P < .0001). Avoiding valgus imbalance at 90-degree flexion and aiming for strictly equal soft tissue tension between 90-degree flexion and 0-degree extension had little practical value with regard to knee flexion angle 2 years after posterior stabilized TKA. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.
Mizu-Uchi, Hideki; Colwell, Clifford W; Fukagawa, Shingo; Matsuda, Shuichi; Iwamoto, Yukihide; D'Lima, Darryl D
2012-10-01
We constructed patient-specific models from computed tomography data after total knee arthroplasty to predict knee flexion based on implant-bone impingement. The maximum flexion before impingement between the femur and the tibial insert was computed using a musculoskeletal modeling program (KneeSIM; LifeModeler, Inc, San Clemente, California) during a weight-bearing deep knee bend. Postoperative flexion was measured in a clinical cohort of 21 knees (low-flex group: 6 knees with <100° of flexion and high-flex group: 15 size-matched knees with >125° of flexion at 2 years). Average predicted flexion angles were within 2° of clinical measurements for the high-flex group. In the low-flex group, 4 cases had impingement involving the bone cut at the posterior condyle, and the average predicted knee flexion was 102° compared with 93° measured clinically. These results indicate that the level of the distal femoral resection should be carefully planned and that exposed bone proximal to the tips of the posterior condyles of the femoral component should be removed if there is risk of impingement. Copyright © 2012 Elsevier Inc. All rights reserved.
Chong, Helen C; Tennant, Liana M; Kingston, David C; Acker, Stacey M
2017-03-01
(1) Characterize knee joint moments and peak knee flexion moment timing during kneeling transitions, with the intent of identifying high-risk postures. (2) Determine whether safety footwear worn by kneeling workers (construction workers, tile setters, masons, roofers) alters high flexion kneeling mechanics. Fifteen males performed high flexion kneeling transitions. Kinetics and kinematics were analyzed for differences in ascent and descent in the lead and trail legs. Mean±standard deviation peak external knee adduction and flexion moments during transitions ranged from 1.01±0.31 to 2.04±0.66% body weight times height (BW∗Ht) and from 3.33 to 12.6% BW∗Ht respectively. The lead leg experienced significantly higher adduction moments compared to the trail leg during descent, when work boots were worn (interaction, p=0.005). There was a main effect of leg (higher lead vs. trail) on the internal rotation moment in both descent (p=0.0119) and ascent (p=0.0129) phases. Peak external knee adduction moments during transitions did not exceed those exhibited during level walking, thus increased knee adduction moment magnitude is likely not a main factor in the development of knee OA in occupational kneelers. Additionally, work boots only significantly increased the adduction moment in the lead leg during descent. In cases where one knee is painful, diseased, or injured, the unaffected knee should be used as the lead leg during asymmetric bilateral kneeling. Peak flexion moments occurred at flexion angles above the maximum flexion angle exhibited during walking (approximately 60°), supporting the theory that the loading of atypical surfaces may aid disease development or progression. Copyright © 2016 Elsevier B.V. All rights reserved.
Morimoto, Yusuke; Ferretti, Mario; Ekdahl, Max; Smolinski, Patrick; Fu, Freddie H
2009-01-01
The purpose of this study was to compare the tibiofemoral contact area and pressure after single-bundle (SB) and double-bundle (DB) anterior cruciate ligament (ACL) reconstruction by use of 2 femoral and 2 tibial tunnels in intact cadaveric knees. Tibiofemoral contact area and mean and maximum pressures were measured by pressure-sensitive film (Fujifilm, Valhalla, NY) inserted between the tibia and femur. The knee was subjected to a 1,000-N axial load by use of a uniaxial testing machine at 0 degrees , 15 degrees , 30 degrees , and 45 degrees of flexion. Three conditions were evaluated: (1) intact ACL, (2) SB ACL reconstruction (n = 10 knees), and (3) DB ACL reconstruction (n = 9 knees). When compared with the intact knee, DB ACL reconstruction showed no significant difference in tibiofemoral contact area and mean and maximum pressures. SB ACL reconstruction had a significantly smaller contact area on the lateral and medial tibiofemoral joints at 30 degrees and 15 degrees of flexion. SB ACL reconstruction also had significantly higher mean pressures at 15 degrees of flexion on the medial tibiofemoral joint and at 0 degrees and 15 degrees of flexion on the lateral tibiofemoral joint, as well as significantly higher maximum pressures at 15 degrees of flexion on the lateral tibiofemoral joint. SB ACL reconstruction resulted in a significantly smaller tibiofemoral contact area and higher pressures. DB ACL more closely restores the normal contact area and pressure mainly at low flexion angles. Our findings suggest that the changes in the contact area and pressures after SB ACL reconstruction may be one of the causes of osteoarthritis on long-term follow-up. DB ACL reconstruction may reduce the incidence of osteoarthritis by closely restoring contact area and pressure.
On hydrodynamics of drag and lift of the human arm.
Gardano, Paola; Dabnichki, Peter
2006-01-01
The work presents results on drag and lift measurement conducted in a low speed wind tunnel on a replica of the entire human arm. The selected model positions were identical to those during purely rotational front crawl stroke in quasi-static conditions. A computational fluid dynamics model using Fluent showed close correspondence with the experimental results and confirmed the suitability of low speed wind tunnel for the drag and lift measurement in quasi-static conditions. The obtained profiles of the hydrodynamic forces were similar to the dynamic data presented in an earlier study suggesting that shape drag is a major contributing factor in propulsive force generation. The aim of this study was to underline the importance of the entire arm analysis, the elbow angle and a newly defined angle of attack representing the angle of shoulder rotation. It was found that both the maximum value of the drag force at 160 degrees elbow flexion angle and the momentum generated by it exceed the respective magnitudes for the fully extended arm. The latter is underlined by a prolonged plateau of near maximum drag that was obtained at shoulder angle range of 50-140 degrees suggesting that optimal arm configuration in terms of propulsive force generation requires elbow flexion. Furthermore it was found that drag trend is not consistent with the widely assumed and used sinus wave profile. A gap in the existing experimental research was filled as for the first time the entire arm lift and drag was measured across the entire stroke range.
Investigating locomotion of dairy cows by use of high speed cinematography.
Herlin, A H; Drevemo, S
1997-05-01
The longterm influence of management systems on the locomotion of 17 dairy cows was investigated by high speed cinematography (100 frames/s) and kinematic analysis. Angular patterns and hoof trajectories of the left fore- and hindlimbs are presented and statistics made of occurring minimum and maximum angles. At the recording, 3 cows had been kept in tie-stalls (TI) and 6 cows in cubicles (CI) for a consecutive time of about 2.5 years while 8 cows had been kept on grass for about 3 months. Four of the grazing cows had earlier been kept in cubicles (CG) and 4 in tie-stalls (TG) during earlier off grazing seasons together with TI and CI cows. The CI cows had a smaller maximum angle of the elbow joint compared to TI, TG and CG cows. The hock joint angle of the CI cows was less flexed during the stance phase than in TI and CG cows while the minimum angle during the swing phase was greater in the TI and CI cows compared to TG and CG cows. Pastured cows (TG and CG) had a less pronounced flexion of the fetlock joint angle during the stance compared to cows kept indoors (TI and CI). The results suggest that slatted floor and lack of exercise during summer grazing may affect locomotion. This is indicated by restrictions in the movements of the elbow and hock joints and in less fetlock joint flexion at full support.
Wilderman, Danielle R; Ross, Scott E; Padua, Darin A
2009-01-01
Context: Improving neuromuscular control of hamstrings muscles might have implications for decreasing anterior cruciate ligament injuries in females. Objective: To examine the effects of a 6-week agility training program on quadriceps and hamstrings muscle activation, knee flexion angles, and peak vertical ground reaction force. Design: Prospective, randomized clinical research trial. Setting: Sports medicine research laboratory. Patients or Other Participants: Thirty female intramural basketball players with no history of knee injury (age = 21.07 ± 2.82 years, height = 171.27 ± 4.66 cm, mass = 66.36 ± 7.41 kg). Intervention(s): Participants were assigned to an agility training group or a control group that did not participate in agility training. Participants in the agility training group trained 4 times per week for 6 weeks. Main Outcome Measure(s): We used surface electromyography to assess muscle activation for the rectus femoris, vastus medialis oblique, medial hamstrings, and lateral hamstrings for 50 milliseconds before initial ground contact and while the foot was in contact with the ground during a side-step pivot maneuver. Knee flexion angles (at initial ground contact, maximum knee flexion, knee flexion displacement) and peak vertical ground reaction force also were assessed during this maneuver. Results: Participants in the training group increased medial hamstrings activation during ground contact after the 6-week agility training program. Both groups decreased their vastus medialis oblique muscle activation during ground contact. Knee flexion angles and peak vertical ground reaction force did not change for either group. Conclusions: Agility training improved medial hamstrings activity in female intramural basketball players during a side-step pivot maneuver. Agility training that improves hamstrings activity might have implications for reducing anterior cruciate ligament sprain injury associated with side-step pivots. PMID:19180214
Articular contact pressures of meniscal repair techniques at various knee flexion angles.
Flanigan, David C; Lin, Fang; Koh, Jason L; Zhang, Li-Qun
2010-07-13
Articular cartilage injury can occur after meniscal repair with biodegradable implants. Previous contact pressure analyses of the knee have been based on the tibial side of the meniscus at limited knee flexion angles. We investigated articular contact pressures on the posterior femoral condyle with different knee flexion angles and surgical repair techniques. Medial meniscus tears were repaired in 30 fresh bovine knees. Knees were mounted on a 6-degrees-of-freedom jig and statically loaded to 200 N at 45 degrees, 70 degrees, 90 degrees, and 110 degrees of knee flexion under 3 conditions: intact meniscus, torn meniscus, and meniscus after repair. For each repair, 3 sutures or biodegradable implants were used. A pressure sensor was used to determine the contact area and peak pressure. Peak pressures over each implant position were measured. Peak pressure increased significantly as knee flexion increased in normal, injured, and repaired knees. The change in peak pressure in knees with implant repairs was significantly higher than suture repairs at all knee flexion angles. Articular contact pressure on the posterior femoral condyle increased with knee flexion. Avoidance of deep knee flexion angles postoperatively may limit increases in articular contact pressures and potential chondral injury. Copyright 2010, SLACK Incorporated.
Iwanuma, Soichiro; Akagi, Ryota; Hashizume, Satoru; Kanehisa, Hiroaki; Yanai, Toshimasa; Kawakami, Yasuo
2011-09-23
The purpose of this study was to clarify how foot deformation affects the relationship between triceps surae muscle-tendon unit (MTU) length and ankle joint angle. For six women and six men a series of sagittal magnetic resonance (MR) images of the right foot were taken, and changes in MTU length (the displacement of the calcaneal tuberosity), foot arch angle, and ankle joint angle were measured. In the passive session, each subject's ankle joint was secured at 10° dorsiflexed position, neutral position (NP), and 10° and 20° plantar flexed positions while MR images were acquired. In the active session, each subject was requested to perform submaximal isometric plantar flexions (30%, 60%, and 80% of voluntary maximum) at NP. The changes in MTU length in each trial were estimated by two different formulae reported previously. The changes of the measured MTU length as a function of ankle joint angles observed in all trials of the active session were significantly (p<0.05) larger than corresponding values in the passive session and by the estimation formulae. In the passive session, MTU length changes were significantly smaller than the estimated values when the ankle was plantar flexed. The foot arch angle increased as the contraction level increased from rest (117 ± 4°) to 80% (125 ± 3°), and decreased as the ankle was positioned further into plantar flexion in the passive session (115 ± 3°). These results indicate that foot deformation profoundly affects the triceps surae MTU length-ankle joint angle relationship during plantar flexion. Copyright © 2011 Elsevier Ltd. All rights reserved.
Kim, Sung-Jae; Chun, Yong-Min; Kim, Sung-Hwan; Moon, Hong-Kyo; Jang, Jae-Won
2013-07-01
The purpose of this study was to compare four graft-tunnel angles (GTA), the femoral GTA formed by three different femoral tunneling techniques (the outside-in, a modified inside-out technique in the posterior sag position with knee hyperflexion, and the conventional inside-out technique) and the tibia GTA in 3-dimensional (3D) knee flexion models, as well as to examine the influence of femoral tunneling techniques on the contact pressure between the intra-articular aperture of the femoral tunnel and the graft. Twelve cadaveric knees were tested. Computed tomography scans were performed at different knee flexion angles (0°, 45°, 90°, and 120°). Femoral and tibial GTAs were measured at different knee flexion angles on the 3D knee models. Using pressure sensitive films, stress on the graft of the angulation of the femoral tunnel aperture was measured in posterior cruciate ligament reconstructed cadaveric knees. Between 45° and 120° of knee flexion, there were no significant differences between the outside-in and modified inside-out techniques. However, the femoral GTA for the conventional inside-out technique was significantly less than that for the other two techniques (p<0.001). In cadaveric experiments using pressure-sensitive film, the maximum contact pressure for the modified inside-out and outside-in technique was significantly lower than that for the conventional inside-out technique (p=0.024 and p=0.017). The conventional inside-out technique results in a significantly lesser GTA and higher stress at the intra-articular aperture of the femoral tunnel than the outside-in technique. However, the results for the modified inside-out technique are similar to those for the outside-in technique.
Revisiting the anatomy and biomechanics of the anconeus muscle and its role in elbow stability.
Pereira, Barry P
2013-07-01
Recent studies have designated the anconeus muscle as an option for use as a pedicled flap for covering soft tissue defects about the elbow, with reported minimal risk of morbidity. This has raised the question as to the importance of the anconeus muscle and as to whether this is truly an accessory muscle that can be sacrificed, or whether the anconeus muscle significantly contributes to elbow and forearm stability? This study revisits the anatomy and biomechanics of the anconeus muscle and aims to investigate the neuromuscular compartments of the anconeus muscle and to determine the changes in the muscle length, fibre length and moment arm over a range of elbow flexion angles for each compartment. An anatomical study on 8 human cadavers (51-77 years of age) was done and a 2-dimensional kinematic elbow model developed to determine changes in the muscle length and moment arm of the muscle related to changes in elbow flexion angles. The muscle was modelled with two possible lines of action, one along the posterior and another on the anterior edge of the muscle as they had different muscle fibre lengths (posterior: average of 32 mm, anterior: average of 20 mm). The anterior edge also had an aponeurosis which was 70% of its length. From 0 to 120° elbow flexion, the length of the posterior and anterior edges increased with a maximum change recorded at 90° elbow flexion (31.7±1.0 mm and 65.3±1.4 mm, respectively). The moment arm is 14-mm at 0° flexion, but between the posterior and anterior edges it decreases at different rates with increasing elbow flexion angle. Beyond 80°, the anterior edge behaves as an elbow flexor, while the posterior edge remains an elbow extensor. The study demonstrates that the anconeus muscle has two neuromuscular compartments each with distinct intramuscular innervations and muscle fibre lengths. The posterior and deep aspect of the muscle functions as an elbow extensor decreasing in influence with increasing elbow flexion angle. The anterior superficial aspect which is adjacent and parallel to the lateral collateral ligaments, would most likely work in unison to provide constraint to the posterolateral stability of the elbow. Copyright © 2012. Published by Elsevier GmbH.
Myers, Casey A.; Torry, Michael R.; Peterson, Daniel S.; Shelburne, Kevin B.; Giphart, J. Erik; Krong, Jacob P.; Woo, Savio L-Y.; Steadman, J. Richard
2014-01-01
Background Previous laboratory studies of landing have defined landing techniques in terms of soft or stiff landings according to the degree of maximal knee flexion angle attained during the landing phase and the relative magnitude of the ground-reaction force. Current anterior cruciate ligament injury prevention programs are instructing athletes to land softly to avoid excessive strain on the anterior cruciate ligament. Purpose This study was undertaken to measure, describe, and compare tibiofemoral rotations and translations of soft and stiff landings in healthy individuals using biplane fluoroscopy. Study Design Controlled laboratory study. Methods The in vivo, lower extremity, 3-dimensional knee kinematics of 16 healthy adults (6 male and 10 female) instructed to land softly and stiffly in different trials were collected in biplane fluoroscopy as they performed the landing from a height of 40 cm. Results Average and maximum relative anterior tibial translation (average, 2.8 ± 1.2 mm vs 3.0 ± 1.4 mm; maximum, 4.7 ± 1.6 mm vs 4.4 ± 0.8 mm), internal/external rotation (average, 3.7° ± 5.1° vs 2.7° ± 4.3°; maximum, 5.6° ± 5.5° vs 4.9° ± 4.7°), and varus/valgus (average, 0.2° ± 1.2° vs 0.2° ± 1.0°; maximum, 1.7° ± 1.2° vs 1.6° ± 0.9°) were all similar between soft and stiff landings, respectively. The peak vertical ground-reaction force was significantly larger for stiff landings than for soft landings (2.60 ± 1.32 body weight vs 1.63 ± 0.73; P < .001). The knee flexion angle total range of motion from the minimum angle at contact to the maximum angle at peak knee flexion was significantly greater for soft landings than for stiff (55.4° ± 8.8° vs 36.8° ± 11.1°; P < .01). Conclusion Stiff landings, as defined by significantly lower knee flexion angles and significantly greater peak ground-reaction forces, do not result in larger amounts of anterior tibial translation or knee rotation in either varus/valgus or internal/external rotation in healthy individuals. Clinical Relevance In healthy knees, the musculature and soft tissues of the knee are able to maintain translations and rotations within a small, safe range during controlled landing tasks of differing demand. The knee kinematics of this healthy population will serve as a comparison for injured knees in future studies. It should be stressed that because the authors did not compare how the loads were distributed over the soft tissues of the knee between the 2 landing styles, the larger ground-reaction forces and more extended knee position observed during stiff landings should still be considered dangerous to the anterior cruciate ligament and other structures of the lower extremities, particularly in competitive settings where movements are often unanticipated. PMID:21602566
Identification of types of landings after blocking in volleyball associated with risk of ACL injury.
Zahradnik, David; Jandacka, Daniel; Farana, Roman; Uchytil, Jaroslav; Hamill, Joseph
2017-03-01
Landing with a low knee flexion angle after volleyball block jumps may be associated with an increased risk of anterior cruciate ligament (ACL) injury. The aim of the present study was to identify the types of volleyball landings after blocks where the knee flexion angle is found to be under a critical knee flexion angle value of 30° at the instant of the first peak of the ground reaction force (GRF). Synchronized kinematic and kinetic data were collected for each trial. T-tests were used to determine if each knee flexion angle at the instant of the peak GRF was significantly different from the critical value of 30°. A repeated measures ANOVA was used to compare knee flexion angle, time to first peak and the magnitude of the first peak of the resultant GRF and knee stiffness. Significantly lower knee flexion angles were found in the "go" landing (p = .01, ES = 0.6) and the "reverse" landing (p = .02, ES = 0.6) only. The results for knee flexion angle and GRF parameters indicated a significant difference between a "reverse" and "go" and other types of landings, except the "side stick" landing for GRF. The "reverse" and "go" landings may present a risk for ACL injury due to the single-leg landing of these activities that have an associated mediolateral movement.
Ameer, Mariam A; Muaidi, Qassim I
2017-09-01
The relationship between knee kinematics and knee-ankle kinetics during the landing phase of single leg jumping has been widely studied to identify proper strategies for preventing non-contact ACL injury. However, there is a lack of study on knee-ankle kinetics at peak knee flexion angle during jumping from running. Hence, the purpose of this study is to establish the relationship between peak knee flexion angle, knee extension moment, ankle plantar flexion moment and ground reaction force in handball players in order to protect ACL from excessive stress during single leg jumping. In addition, the study also clarifies the role of calf muscles in relieving part of ACL stresses with different knee flexion angles during landing. Fifteen active male elite handball players of Saudi Arabia have participated in this study (Age = 22.6 ± 3.5years, Height = 182 ± 3.7 cm, Weight = 87.5 ± 10.2 kg). The players performed three successful landings of single-leg jump following running a fixed distance of about 450cm. The data were collected using a 3D motion capture and analysis system (VICON). Pearson product moment correlation coefficients showed that greater peak knee flexion angle is related significantly to both lesser knee extension moment (r = -.623, P = .013) and vertical component of ground reaction force (VGRF) (r = -.688, P = .005) in landing phase. Moreover, increasing the peak knee flexion angle in landing phase tends to increase the ankle plantar flexion moment significantly (r = .832, P = .000). With an increase of the peak knee flexion angle during single leg jump landing from running, there would be less knee extension moment, low impact force and more plantar flexion moment. As such, the clinical implication of this study is that there may be a possible protective mechanism by increasing the knee flexion angle during landing phase, which tends to protect the ACL from vigorous strain and injuries.
The spinal posture of computing adolescents in a real-life setting
2014-01-01
Background It is assumed that good postural alignment is associated with the less likelihood of musculoskeletal pain symptoms. Encouraging good sitting postures have not reported consequent musculoskeletal pain reduction in school-based populations, possibly due to a lack of clear understanding of good posture. Therefore this paper describes the variability of postural angles in a cohort of asymptomatic high-school students whilst working on desk-top computers in a school computer classroom and to report on the relationship between the postural angles and age, gender, height, weight and computer use. Methods The baseline data from a 12 month longitudinal study is reported. The study was conducted in South African school computer classrooms. 194 Grade 10 high-school students, from randomly selected high-schools, aged 15–17 years, enrolled in Computer Application Technology for the first time, asymptomatic during the preceding month, and from whom written informed consent were obtained, participated in the study. The 3D Posture Analysis Tool captured five postural angles (head flexion, neck flexion, cranio-cervical angle, trunk flexion and head lateral bend) while the students were working on desk-top computers. Height, weight and computer use were also measured. Individual and combinations of postural angles were analysed. Results 944 Students were screened for eligibility of which the data of 194 students are reported. Trunk flexion was the most variable angle. Increased neck flexion and the combination of increased head flexion, neck flexion and trunk flexion were significantly associated with increased weight and BMI (p = 0.0001). Conclusions High-school students sit with greater ranges of trunk flexion (leaning forward or reclining) when using the classroom computer. Increased weight is significantly associated with increased sagittal plane postural angles. PMID:24950887
Ali, Nicholas; Rouhi, Gholamreza; Robertson, Gordon
2013-01-01
There is a lack of studies investigating gender differences in whole-body kinematics during single-leg landings from increasing vertical heights and horizontal distances. This study determined the main effects and interactions of gender, vertical height, and horizontal distance on whole-body joint kinematics during single-leg landings, and established whether these findings could explain the gender disparity in non-contact anterior cruciate ligament (ACL) injury rate. Recreationally active males (n=6) and females (n=6) performed single-leg landings from a takeoff deck of vertical height of 20, 40, and 60 cm placed at a horizontal distance of 30, 50 and 70 cm from the edge of a force platform, while 3D kinematics and kinetics were simultaneously measured. It was determined that peak vertical ground reaction force (VGRF) and the ankle flexion angle exhibited significant gender differences (p=0.028, partial η(2)=0.40 and p=0.035, partial η(2)=0.37, respectively). Peak VGRF was significantly correlated to the ankle flexion angle (r= -0.59, p=0.04), hip flexion angle (r= -0.74, p=0.006), and trunk flexion angle (r= -0.59, p=0.045). Peak posterior ground reaction force (PGRF) was significantly correlated to the ankle flexion angle (r= -0.56, p=0.035), while peak knee abduction moment was significantly correlated to the knee flexion angle (r= -0.64, p=0.03). Rearfoot landings may explain the higher ACL injury rate among females. Higher plantar-flexed ankle, hip, and trunk flexion angles were associated with lower peak ground reaction forces, while higher knee flexion angle was associated with lower peak knee abduction moment, and these kinematics implicate reduced risk of non-contact ACL injury.
Kim, Hee-June; Lee, Hyun-Joo; Shin, Ji-Yeon; Choi, Young-Seo; Kyung, Hee-Soo
2017-12-01
This study evaluated the efficacy of a smartphone application in the measurement of rotation angles in porcine knees. Two K-wires were fixated to the femoral condyle and anterior tibial crest of 10 porcine legs. The angle created between the K-wires with an external rotation force applied was measured on a photograph and defined as the true angle. The same force was applied to the legs placed on a splint with a smartphone attached to the plantar side. The angle presented on a smartphone application was determined as the measured angle. The differences between the true and measured angles in 30° and 90° knee flexion and differences in measured angles depending on the status of the popliteus tendon were compared. In the intact knees, the mean true angles in 30° and 90° flexion were 20.5°±1.4° and 19.1°±1.3°, respectively, and the mean measured angles in 30° and 90° flexion were 21.1°±0.9° and 18.6°±1.6°, respectively. When the popliteus tendon was cut, the mean true angles in 30° and 90° flexion were 31.4°±1.1° and 38.5°±2.5°, respectively, and the mean measured angles in 30° and 90° flexion were 31.8°±1.2° and 39.2°±2.8°, respectively. The differences between the true and measured angles were not significant. The measured angle increased by more than 10° after cutting of the popliteus tendon in both 30° and 90° flexion. Using a smartphone application could be a good method of measuring knee rotation.
Cao, Wujing; Yu, Hongliu; Zhao, Weiliang; Li, Jin; Wei, Xiaodong
2018-01-01
Prosthetic knee is the most important component of lower limb prosthesis. Speed adaptive for prosthetic knee during swing flexion is the key method to realize physiological gait. This study aims to discuss the target of physiological gait, propose a speed adaptive control method during swing flexion and research the damping adjustment law of intelligent hydraulic prosthetic knee. According to the physiological gait trials of healthy people, the control target during swing flexion is defined. A new prosthetic knee with fuzzy logical control during swing flexion is designed to realize the damping adjustment automatically. The function simulation and evaluation system of intelligent knee prosthesis is provided. Speed adaptive control test of the intelligent prosthetic knee in different velocities are researched. The maximum swing flexion of the knee angle is set between sixty degree and seventy degree as the target of physiological gait. Preliminary experimental results demonstrate that the prosthetic knee with fuzzy logical control is able to realize physiological gait under different speeds. The faster the walking, the bigger the valve closure percentage of the hydraulic prosthetic knee. The proposed fuzzy logical control strategy and intelligent hydraulic prosthetic knee are effective for the amputee to achieve physiological gait.
Ishii, Yoshinori; Noguchi, Hideo; Takeda, Mitsuhiro; Sato, Junko; Sakurai, Tetsuya; Toyabe, Shin-Ichi
2014-08-01
Anteroposterior (AP) joint translation is an important indicator of good clinical outcome following total knee arthroplasty (TKA). This study evaluated the in vivo relationship between changes in the degree of voluntary soft tissue tension and flexion angle versus simultaneous AP translation after TKA. A posterior cruciate ligament (PCL)-retaining meniscal-bearing design was investigated in 20 knees of 20 patients. AP translation was measured at 30° and 75° flexion with the KT-2000 arthrometer while patients were anesthetized and non-anesthetized. The mean translations at 30° and 75° were 10.5 and 10.4 mm, respectively, in non-anesthetized patients and 13.8 and 12.7 mm, respectively, in patients under anesthesia. AP translation showed a significant positive correlation with soft tissue tension (p < 0.001), but not with flexion angle (p = 0.366). No interaction was observed between soft tissue tension and the flexion angle in terms of AP translation (p = 0.431). Surgeons should recognize that AP translation is greater in anesthetized patients than in non-anesthetized patients, regardless of the flexion angle, with no significant correlation between flexion angle and translation, regardless of the level of consciousness. Because conformity between the tibial insert and femoral component decreases with flexion, whereas the opposing effects of supporting structures, such as muscles, ligaments, and capsules, increases, proper soft tissue tension, particularly retention of a functional PCL, could have an important role in determining AP translation in the current prosthesis design.
An Investigation into the Relation between the Technique of Movement and Overload in Step Aerobics
Wysocka, Katarzyna
2017-01-01
The aim of this research was to determine the features of a step workout technique which may be related to motor system overloading in step aerobics. Subjects participating in the research were instructors (n = 15) and students (n = 15) without any prior experience in step aerobics. Kinematic and kinetic data was collected with the use of the BTS SMART system comprised of 6 calibrated video cameras and two Kistler force plates. The subjects' task was to perform basic steps. The following variables were analyzed: vertical, anteroposterior, and mediolateral ground reaction forces; foot flexion and abduction and adduction angles; knee joint flexion angle; and trunk flexion angle in the sagittal plane. The angle of a foot adduction recorded for the instructors was significantly smaller than that of the students. The knee joint angle while stepping up was significantly higher for the instructors compared to that for the students. Our research confirmed that foot dorsal flexion and adduction performed while stepping up increased load on the ankle joint. Both small and large angles of knee flexion while stepping up and down resulted in knee joint injuries. A small trunk flexion angle in the entire cycle of step workout shut down dorsal muscles, which stopped suppressing the load put on the spine. PMID:28348501
Head flexion angle while using a smartphone.
Lee, Sojeong; Kang, Hwayeong; Shin, Gwanseob
2015-01-01
Repetitive or prolonged head flexion posture while using a smartphone is known as one of risk factors for pain symptoms in the neck. To quantitatively assess the amount and range of head flexion of smartphone users, head forward flexion angle was measured from 18 participants when they were conducing three common smartphone tasks (text messaging, web browsing, video watching) while sitting and standing in a laboratory setting. It was found that participants maintained head flexion of 33-45° (50th percentile angle) from vertical when using the smartphone. The head flexion angle was significantly larger (p < 0.05) for text messaging than for the other tasks, and significantly larger while sitting than while standing. Study results suggest that text messaging, which is one of the most frequently used app categories of smartphone, could be a main contributing factor to the occurrence of neck pain of heavy smartphone users. Practitioner Summary: In this laboratory study, the severity of head flexion of smartphone users was quantitatively evaluated when conducting text messaging, web browsing and video watching while sitting and standing. Study results indicate that text messaging while sitting caused the largest head flexion than that of other task conditions.
Isometric hip-rotator torque production at varying degrees of hip flexion.
Johnson, Sam; Hoffman, Mark
2010-02-01
Hip torque production is associated with certain knee injuries. The hip rotators change function depending on hip angle. To compare hip-rotator torque production between 3 angles of hip flexion, limbs, and sexes. Descriptive. University sports medicine research laboratory. 15 men and 15 women, 19-39 y. Three 6-s maximal isometric contractions of the hip external and internal rotators at 10 degrees, 40 degrees, and 90 degrees of hip flexion on both legs. Average torque normalized to body mass. Internal-rotation torque was greatest at 90 degrees of hip flexion, followed by 40 degrees of hip flexion and finally 10 degrees of hip flexion. External-rotation torque was not different based on hip flexion. The nondominant leg's external rotators were stronger than the dominant leg's, but the reverse was true for internal rotators. Finally, the men had more overall rotator torque. Hip-rotation torque production varies between flexion angle, leg, and sex. Clinicians treating lower extremity problems need to be aware of these differences.
Obeid, Ibrahim; Hauger, Olivier; Aunoble, Stéphane; Bourghli, Anouar; Pellet, Nicolas; Vital, Jean-Marc
2011-09-01
It has become well recognised that sagittal balance of the spine is the result of an interaction between the spine and the pelvis. Knee flexion is considered to be the last compensatory mechanism in case of sagittal imbalance, but only few studies have insisted on the relationship between spino-pelvic parameters and lower extremity parameters. Correlation between the lack of lumbar lordosis and knee flexion has not yet been established. A retrospective study was carried out on 28 patients with major spinal deformities. The EOS system was used to measure spinal and pelvic parameters and the knee flexion angle; the lack of lumbar lordosis was calculated after prediction of lumbar lordosis with two different formulas. Correlation analysis between the different measured parameters was performed. Lumbar lordosis correlated with sacral slope (r = -0.71) and moderately with knee flexion angle (r = 0.42). Pelvic tilt correlated moderately with knee flexion angle (r = 0.55). Lack of lumbar lordosis correlated best with knee flexion angle (r = 0.72 and r = 0.63 using the two formulas, respectively). Knee flexion as a compensatory mechanism to sagittal imbalance was well correlated to the lack of lordosis and, depending on the importance of the former parameter, the best procedure to correct sagittal imbalance could be chosen.
Knee Proprioception and Strength and Landing Kinematics During a Single-Leg Stop-Jump Task
Nagai, Takashi; Sell, Timothy C; House, Anthony J; Abt, John P; Lephart, Scott M
2013-01-01
Context The importance of the sensorimotor system in maintaining a stable knee joint has been recognized. As individual entities, knee-joint proprioception, landing kinematics, and knee muscles play important roles in functional joint stability. Preventing knee injuries during dynamic tasks requires accurate proprioceptive information and adequate muscular strength. Few investigators have evaluated the relationship between knee proprioception and strength and landing kinematics. Objective To examine the relationship between knee proprioception and strength and landing kinematics. Design Cross-sectional study. Setting University research laboratory. Patients or Other Participants Fifty physically active men (age = 26.4 ± 5.8 years, height = 176.5 ± 8.0 cm, mass = 79.8 ± 16.6 kg). Intervention(s) Three tests were performed. Knee conscious proprioception was evaluated via threshold to detect passive motion (TTDPM). Knee strength was evaluated with a dynamometer. A 3-dimensional biomechanical analysis of a single-legged stop-jump task was used to calculate initial contact (IC) knee-flexion angle and knee-flexion excursion. Main Outcome Measure(s) The TTDPM toward knee flexion and extension, peak knee flexion and extension torque, and IC knee-flexion angle and knee flexion excursion. Linear correlation and stepwise multiple linear regression analyses were used to evaluate the relationships of both proprioception and strength against landing kinematics. The α level was set a priori at .05. Results Enhanced TTDPM and greater knee strength were positively correlated with greater IC knee-flexion angle (r range = 0.281–0.479, P range = .001–.048). The regression analysis revealed that 27.4% of the variance in IC knee-flexion angle could be accounted for by knee-flexion peak torque and TTDPM toward flexion (P = .001). Conclusions The current research highlighted the relationship between knee proprioception and strength and landing kinematics. Individuals with enhanced proprioception and muscular strength had better control of IC knee-flexion angle during a dynamic task. PMID:23672323
Cesarean Delivery Changes the Natural Position of the Uterus on Transvaginal Ultrasonography.
Kaelin Agten, Andrea; Honart, Anne; Monteagudo, Ana; McClelland, Spencer; Basher, Basmy; Timor-Tritsch, Ilan E
2018-05-01
To assess whether cesarean delivery changes the natural position of the uterus. In this retrospective Institutional Review Board-approved cohort study, we conducted a search of our university gynecologic ultrasonography (US) database. Patients with transvaginal US images before and after either vaginal or cesarean delivery between 2012 and 2015 were included. Women with prior cesarean delivery were excluded. Two readers independently measured antepartum and postpartum flexion angles between the longitudinal axis of the uterine body and the cervix. We calculated intraclass correlation coefficients to measure inter-reader agreement. Antepartum and postpartum uterine flexion angles were compared between patients with vaginal and cesarean delivery. We included 173 patients (107 vaginal and 66 cesarean delivery). The mean interval between scans ± SD was 18 ± 10 months. Inter-reader agreement for flexion angles was almost perfect (intraclass correlation coefficients: antepartum, 0.939; postpartum, 0.969; both P < .001). There was no difference in mean antepartum flexion angles for cesarean delivery (154.8° ± 45.7°) versus vaginal delivery (145.8° ± 43.7°; P = .216). Mean postpartum flexion angles were higher after cesarean delivery (180.4° ± 51.2°) versus vaginal delivery (152.8° ± 47.7°; P = .001. Differences in antepartum and postpartum flexion angles between cesarean and vaginal delivery were statistically significant (25.6° versus 7.0°; P = .027). Cesarean delivery can change the uterine flexion angle to a more retroflexed position. Therefore, all women with a history of cesarean delivery should undergo a transvaginal US examination before any gynecologic surgery or intrauterine device placement to reduce the possibility of surgical complications. © 2017 by the American Institute of Ultrasound in Medicine.
Park, Sang Eun; Lee, Chun Taek
2007-10-01
This study was aimed to compare robotic-assisted implantation of a total knee arthroplasty with conventional manual implantation. We controlled, randomized, and reviewed 72 patients for total knee arthroplasty assigned to undergo either conventional manual implantation (excluding navigation-assisted implantation cases) of a Zimmer LPS prosthesis (Zimmer, Warsaw, Ind) (30 patients: group 1) or robotic-assisted implantation of such a prosthesis (32 patients: group 2). The femoral flexion angle (gamma angle) and tibial angle (delta angle) in the lateral x-ray of group 1 were 4.19 +/- 3.28 degrees and 89.7 +/- 1.7 degrees, and those of group 2 were 0.17 +/- 0.65 degrees and 85.5 +/- 0.92 degrees. The major complications were from improper small skin incision during a constraint attempt of minimally invasive surgery and during bulk fixation frame pins insertion. Robotic-assisted technology had definite advantages in terms of preoperative planning, accuracy of the intraoperative procedure, and postoperative follow-up, especially in the femoral flexion angle (gamma angle) and tibial flexion angle (delta angle) in the lateral x-ray, and in the femoral flexion angle (alpha angle) in the anteroposterior x-ray. But a disadvantage was the high complication rate in early stage.
Herrington, Lee; Bendix, Katie; Cornwell, Catherine; Fielden, Nicola; Hankey, Karen
2008-08-01
The purpose of the study was to assess the effect of structural differentiation or sensitising manoeuvres on responses of normal subjects to standard neurodynamic tests of straight leg raise (SLR) and slump test. Eighty-eight (39 males and 49 females) asymptomatic subjects were examined (aged 18-39 mean age 21.9+/-4.1 years). Knee flexion angle was measured using a goniometer during the slump test in two conditions cervical flexion and extension. Hip flexion angle was measured using a goniometer during SLR test in two conditions; ankle dorsi-flexion and neutral. The change in knee flexion, following addition of the structural differentiating manoeuvre to the slump test, was a significant increase in knee flexion angle for both males (change in knee angle; 6.6+/-4.7 degrees /18.7+/-17.5%, p<0.01) and females (change in knee angle 5.4+/-5.8 degrees /17.6+/-23.7%, p<0.01), though showed no difference between sides (p>0.05). During the SLR test, a significant reduction in hip flexion occurred following structural differentiation for both groups (change in hip angle; males = 9.5+/-8.3 degrees /21.5+/-18.8%, p<0.01; females = 15.2+/-9.5 degrees /25.9+/-13.9%, p<0.01), though showed no difference between sides (p>0.05). Structural differentiating manoeuvres have a significant effect on test response in terms of range of movement even in normal asymptomatic individuals. These responses should be taken into account during the assessment clinical reasoning process.
Analysis of the lateral push-off in the freestyle flip turn.
Araujo, Luciana; Pereira, Suzana; Gatti, Roberta; Freitas, Elinai; Jacomel, Gabriel; Roesler, Helio; Villas-Boas, Joao
2010-09-01
The aim of this study was to examine the contact phase during the lateral push-off in the turn of front crawl swimming to determine which biomechanical variables (maximum normalized peak force, contact time, impulse, angle of knee flexion, and total turn time within 15 m) contribute to the performance of this turn technique. Thirty-four swimmers of state, national, and international competitive standard participated in the study. For data collection, the following equipment was used: an underwater force platform, a 30-Hz VHS video camera, and a MiniDv digital camera within an underwater box. Data are expressed as descriptive statistics. Inferential analyses were performed using Pearson's correlation and multiple linear regressions. All variables studied had a significant relationship with turn performance. We conclude that a turn executed with a knee flexion angle of between 100° and 120° provides optimum peak forces to generate impulses that allow the swimmer to lose less time in the turn without the need for an excessive force application and with less energy lost.
Ko, Dae-Sik; Jung, Dae-In; Jeong, Mi-Ae
2014-11-01
[Purpose] The aim of the present study was to investigate the effects of core stability exercise (CSE) on the physical and psychological functions of elderly women while negotiating general obstacles. [Subjects and Methods] After allocating 10 elderly women each to the core stability training group and the control group, we carried out Performance-Oriented Mobility Assessment (POMA) and measured crossing velocity (CV), maximum vertical heel clearance (MVHC), and knee flexion angle for assessing physical performances. We evaluated depression and fear of falling for assessing psychological functions. [Results] Relative to the control group, the core stability training group showed statistically significant overall changes after the training session: an increase in POMA scores, faster CV, lower MVHC, and a decrease in knee flexion angle. Furthermore, depression and fear of falling decreased significantly. [Conclusion] CSE can have a positive effect on the improvement of physical and psychological performances of older women who are vulnerable to falls as they negotiate everyday obstacles.
Kim, Bo-Been; Lee, Ji-Hyun; Jeong, Hyo-Jung; Cynn, Heon-Seock
2016-10-01
Forward head posture is a head-on-trunk malalignment, which results in musculoskeletal dysfunction and neck pain. To improve forward head posture, both the craniocervical flexion exercise and the suboccipital release technique have been used. The purpose of this study was to compare the immediate effects of craniocervical flexion exercise and suboccipital release combined with craniocervical flexion exercise on craniovertebral angle, cervical flexion and extension range of motion, and the muscle activities of the sternocleidomastoid, anterior scalene, and splenius capitis during craniocervical flexion exercise in subjects with forward head posture. In total, 19 subjects (7 males, 12 females) with forward head posture were recruited using G-power software. Each subject performed craniocervical flexion exercise and suboccipital release combined with craniocervical flexion exercise in random order. After one intervention was performed, the subject took a 20min wash out period to minimize any carry-over effect between interventions. Craniovertebral angle, cervical flexion and extension range of motion, and the muscle activities of the sternocleidomastoid, anterior scalene, and splenius capitis were measured. A one-way, repeated-measures ANOVA was used to assess differences between the effects of the craniocervical flexion exercise and suboccipital release combined with craniocervical flexion exercise interventions in the same group. Craniovertebral angle (p<0.05), cervical flexion range of motion (p<0.05), and cervical extension range of motion (p<0.001) were significantly greater after suboccipital release combined with craniocervical flexion exercise compared to craniocervical flexion exercise alone. The muscle activities of the sternocleidomastoid, anterior scalene, and splenius capitis were significantly lower during suboccipital release combined with craniocervical flexion exercise than during craniocervical flexion exercise alone across all craniocervical flexion exercise phases except the first (all p<0.05). The addition of suboccipital release to craniocervical flexion exercise provided superior benefits relative to craniocervical flexion exercise alone as an intervention for subjects with forward head posture. Copyright © 2016 Elsevier Ltd. All rights reserved.
Liu, Yuzhou; Lao, Jie; Zhao, Xin
2015-04-01
Global brachial plexus injuries (BPIs) are devastating events frequently resulting in severe functional impairment. The widely used nerve transfer sources for elbow flexion in patients with global BPIs include intercostal and phrenic nerves. The aim of this study was to compare phrenic and intercostal nerve transfers for elbow flexion after global BPI. A retrospective review of 33 patients treated with phrenic and intercostal nerve transfer for elbow flexion in posttraumatic global root avulsion BPI was carried out. In the phrenic nerve transfer group, the phrenic nerve was transferred to the anterolateral bundle of the anterior division of the upper trunk (23 patients); in the intercostal nerve transfer group, three intercostal nerves were coapted to the anterolateral bundles of the musculocutaneous nerve. The British Medical Research Council (MRC) grading system, angle of elbow flexion, and electromyography (EMG) were used to evaluate the recovery of elbow flexion at least 3 years postoperatively. The efficiency of motor function in the phrenic nerve transfer group was 83%, while it was 70% in the intercostal nerve transfer group. The two groups were not statistically different in terms of the MRC grade (p=0.646) and EMG results (p=0.646). The outstanding rates of angle of elbow flexion were 48% and 40% in the phrenic and intercostal nerve transfer groups, respectively. There was no significant difference of outstanding rates in the angle of elbow flexion between the two groups. Phrenic nerve transfer had a higher proportion of good prognosis for elbow flexion than intercostal nerve transfer, but the effective and outstanding rate had no significant difference for biceps reinnervation between the two groups according to MRC grading, angle of elbow flexion, and EMG. Copyright © 2014 Elsevier Ltd. All rights reserved.
Andrade, R J; Freitas, S R; Vaz, J R; Bruno, P M; Pezarat-Correia, P
2015-06-01
This study aimed to determine the influence of the head, upper trunk, and foot position on the passive knee extension (PKE) torque-angle response. PKE tests were performed in 10 healthy subjects using an isokinetic dynamometer at 2°/s. Subjects lay in the supine position with their hips flexed to 90°. The knee angle, passive torque, surface electromyography (EMG) of the semitendinosus and quadriceps vastus medialis, and stretch discomfort were recorded in six body positions during PKE. The different maximal active positions of the cervical spine (neutral; flexion; extension), thoracic spine (neutral; flexion), and ankle (neutral; dorsiflexion) were passively combined for the tests. Visual analog scale scores and EMG were unaffected by body segment positioning. An effect of the ankle joint was verified on the peak torque and knee maximum angle when the ankle was in the dorsiflexion position (P < 0.05). Upper trunk positioning had an effect on the knee submaximal torque (P < 0.05), observed as an increase in the knee passive submaximal torque when the cervical and thoracic spines were flexed (P < 0.05). In conclusion, other apparently mechanical unrelated body segments influence torque-angle response since different positions of head, upper trunk, and foot induce dissimilar knee mechanical responses during passive extension. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Design, analysis and verification of a knee joint oncological prosthesis finite element model.
Zach, Lukáš; Kunčická, Lenka; Růžička, Pavel; Kocich, Radim
2014-11-01
The aim of this paper was to design a finite element model for a hinged PROSPON oncological knee endoprosthesis and to verify the model by comparison with ankle flexion angle using knee-bending experimental data obtained previously. Visible Human Project CT scans were used to create a general lower extremity bones model and to compose a 3D CAD knee joint model to which muscles and ligaments were added. Into the assembly the designed finite element PROSPON prosthesis model was integrated and an analysis focused on the PEEK-OPTIMA hinge pin bushing stress state was carried out. To confirm the stress state analysis results, contact pressure was investigated. The analysis was performed in the knee-bending position within 15.4-69.4° hip joint flexion range. The results showed that the maximum stress achieved during the analysis (46.6 MPa) did not exceed the yield strength of the material (90 MPa); the condition of plastic stability was therefore met. The stress state analysis results were confirmed by the distribution of contact pressure during knee-bending. The applicability of our designed finite element model for the real implant behaviour prediction was proven on the basis of good correlation of the analytical and experimental ankle flexion angle data. Copyright © 2014 Elsevier Ltd. All rights reserved.
Becher, Christoph; Fleischer, Benjamin; Rase, Marten; Schumacher, Thees; Ettinger, Max; Ostermeier, Sven; Smith, Tomas
2017-08-01
This study analysed the effects of upright weight bearing and the knee flexion angle on patellofemoral indices, determined using magnetic resonance imaging (MRI), in patients with patellofemoral instability (PI). Healthy volunteers (control group, n = 9) and PI patients (PI group, n = 16) were scanned in an open-configuration MRI scanner during upright weight bearing and supine non-weight bearing positions at full extension (0° flexion) and at 15°, 30°, and 45° flexion. Patellofemoral indices included the Insall-Salvati Index, Caton-Deschamp Index, and Patellotrochlear Index (PTI) to determine patellar height and the patellar tilt angle (PTA), bisect offset (BO), and the tibial tubercle-trochlear groove (TT-TG) distance to assess patellar rotation and translation with respect to the femur and alignment of the extensor mechanism. A significant interaction effect of weight bearing by flexion angle was observed for the PTI, PTA, and BO for subjects with PI. At full extension, post hoc pairwise comparisons revealed a significant effect of weight bearing on the indices, with increased patellar height and increased PTA and BO in the PI group. Except for the BO, no such changes were seen in the control group. Independent of weight bearing, flexing the knee caused the PTA, BO, and TT-TG distance to be significantly reduced. Upright weight bearing and the knee flexion angle affected patellofemoral MRI indices in PI patients, with significantly increased values at full extension. The observations of this study provide a caution to be considered by professionals when treating PI patients. These patients should be evaluated clinically and radiographically at full extension and various flexion angles in context with quadriceps engagement. Explorative case-control study, Level III.
Alavekios, Damon; Peterson, Alexander; Patton, John; McGarry, Michelle H; Lee, Thay Q
2014-11-01
The purpose of this study was to compare the anterior cruciate ligament (ACL) femoral tunnel characteristics between 2 common arthroscopic portals used for ACL reconstruction, a standard anteromedial portal and a far anteromedial portal. Seven cadaveric knees were used. A 1.25-mm Kirschner wire was drilled through the center of the ACL femoral footprint and through the distal femur from the standard anteromedial and far anteromedial portals at knee flexion angles of 100°, 120°, and 140°. No formal tunnels were drilled. Each tunnel exit point was marked with a colored pin. After all tunnels were created, the specimens were digitized with a MicroScribe device (Revware, Raleigh, NC) to measure the tunnel length; distance to the posterior femoral cortical wall (posterior cortical margin); and tunnel orientation in the sagittal, coronal, and axial planes. The standard anteromedial portal resulted in a longer tunnel length, a less horizontal tunnel in the coronal plane, and a greater posterior cortical margin compared with the far anteromedial portal at all knee flexion angles. For both portal locations, the tunnel length and posterior cortical margin increased, and the tunnel position became more horizontal in the coronal plane, more anterior in the sagittal plane, and less horizontal in the transverse plane as knee flexion increased. Portal position affects femoral tunnel characteristics, with results favoring the more laterally positioned standard anteromedial portal at all flexion angles. Increasing the knee flexion angle leads to a longer femoral tunnel length and posterior femoral cortical margin with either portal position. Understanding how portal positioning and knee flexion angle affect femoral tunnel orientation and characteristics may lead to improved surgical outcomes after ACL reconstruction. Published by Elsevier Inc.
An intelligent system with EMG-based joint angle estimation for telemanipulation.
Suryanarayanan, S; Reddy, N P; Gupta, V
1996-01-01
Bio-control of telemanipulators is being researched as an alternate control strategy. This study investigates the use of surface EMG from the biceps to predict joint angle during flexion of the arm that can be used to control an anthropomorphic telemanipulator. An intelligent system based on neural networks and fuzzy logic has been developed to use the processed surface EMG signal and predict the joint angle. The system has been tested on various angles of flexion-extension of the arm and at several speeds of flexion-extension. Preliminary results show the RMS error between the predicted angle and the actual angle to be less than 3% during training and less than 15% during testing. The technique of direct bio-control using EMG has the potential as an interface for telemanipulation applications.
Tibiofemoral Contact Forces in the Anterior Cruciate Ligament-Reconstructed Knee.
Saxby, David John; Bryant, Adam L; Modenese, Luca; Gerus, Pauline; Killen, Bryce A; Konrath, Jason; Fortin, Karine; Wrigley, Tim V; Bennell, Kim L; Cicuttini, Flavia M; Vertullo, Christopher; Feller, Julian A; Whitehead, Tim; Gallie, Price; Lloyd, David G
2016-11-01
To investigate differences in anterior cruciate ligament-reconstructed (ACLR) and healthy individuals in terms of the magnitude of the tibiofemoral contact forces, as well as the relative muscle and external load contributions to those contact forces, during walking, running, and sidestepping gait tasks. A computational EMG-driven neuromusculoskeletal model was used to estimate the muscle and tibiofemoral contact forces in those with single-bundle combined semitendinosus and gracilis tendon autograft ACLR (n = 104, 29.7 ± 6.5 yr, 78.1 ± 14.4 kg) and healthy controls (n = 60, 27.5 ± 5.4 yr, 67.8 ± 14.0 kg) during walking (1.4 ± 0.2 m·s), running (4.5 ± 0.5 m·s) and sidestepping (3.7 ± 0.6 m·s). Within the computational model, the semitendinosus of ACLR participants was adjusted to account for literature reported strength deficits and morphological changes subsequent to autograft harvesting. ACLR had smaller maximum total and medial tibiofemoral contact forces (~80% of control values, scaled to bodyweight) during the different gait tasks. Compared with controls, ACLR were found to have a smaller maximum knee flexion moment, which explained the smaller tibiofemoral contact forces. Similarly, compared with controls, ACLR had both a smaller maximum knee flexion angle and knee flexion excursion during running and sidestepping, which may have concentrated the articular contact forces to smaller areas within the tibiofemoral joint. Mean relative muscle and external load contributions to the tibiofemoral contact forces were not significantly different between ACLR and controls. ACLR had lower bodyweight-scaled tibiofemoral contact forces during walking, running, and sidestepping, likely due to lower knee flexion moments and straighter knee during the different gait tasks. The relative contributions of muscles and external loads to the contact forces were equivalent between groups.
Nawasreh, Zakariya; Failla, Mathew; Marmon, Adam; Logerstedt, David; Snyder-Mackler, Lynn
2018-05-23
Performing physical activities on a compliant surface alters joint kinematics and increases joints stiffness. However, the effect of compliant surface on joint kinematics after ACL-rupture is yet unknown. To compare the effects of mechanical perturbation training with a compliant surface to manual perturbation training on joint kinematics after ACL-rupture. Sixteen level I/II athletes with ACL-rupture participated in this preliminary study. Eight patients received mechanical perturbation with compliant surface (Mechanical) and 8 patients received manual perturbation training (Manual). Patients completed standard gait analysis before (Pre) and after (Post) training. Significant group-by-time interactions were found for knee flexion angle at initial contact (IC) and peak knee flexion (PKF) (p<0.004), with manual group significantly increased knee flexion angle at IC and PKF (p<0.03). Main effects of group were found for hip flexion angle at IC (Manual:34.34+3.51°, Mechanical:27.68+4.08°, p = 0.011), hip rotation angle at PKE (Manual:-3.40+4.78°, Mechanical:5.43+4.78°, p < 0.0001), and knee adduction angle at PKE (Manual:-2.00+2.23°, Mechanical:0.55+2.23°, p = 0.039). Main effects of time were found for hip adduction angle at PKE (Pre:6.98+4.48°, Post:8.41+4.91°, p = 0.04), knee adduction angle at IC (Pre:-2.90+3.50°, Post:-0.62+2.58°, p = 0.03), ankle adduction angle at IC (Pre:2.16+3.54, Post:3.8+3.68, p = 0.008), and ankle flexion angle at PKF (Pre:-4.55+2.77°, Post:-2.39+3.48°, p = 0.01). Training on a compliant surface induces different effects on joint kinematics compared to manual perturbation training after ACL-rupture. Manual perturbation improved hip alignment and increased knee flexion angles, while mechanical training decreased knee flexion angles throughout the stance phase. Administering training on a compliant surface after ACL-rupture may help improving dynamic knee stability, however, long-term effects on knee health needs to be determined. Copyright © 2018 Elsevier B.V. All rights reserved.
Femoral articular geometry and patellofemoral stability.
Iranpour, Farhad; Merican, Azhar M; Teo, Seow Hui; Cobb, Justin P; Amis, Andrew A
2017-06-01
Patellofemoral instability is a major cause of anterior knee pain. The aim of this study was to examine how the medial and lateral stability of the patellofemoral joint in the normal knee changes with knee flexion and measure its relationship to differences in femoral trochlear geometry. Twelve fresh-frozen cadaveric knees were used. Five components of the quadriceps and the iliotibial band were loaded physiologically with 175N and 30N, respectively. The force required to displace the patella 10mm laterally and medially at 0°, 20°, 30°, 60° and 90° knee flexion was measured. Patellofemoral contact points at these knee flexion angles were marked. The trochlea cartilage geometry at these flexion angles was visualized by Computed Tomography imaging of the femora in air with no overlying tissue. The sulcus, medial and lateral facet angles were measured. The facet angles were measured relative to the posterior condylar datum. The lateral facet slope decreased progressively with flexion from 23°±3° (mean±S.D.) at 0° to 17±5° at 90°. While the medial facet angle increased progressively from 8°±8° to 36°±9° between 0° and 90°. Patellar lateral stability varied from 96±22N at 0°, to 77±23N at 20°, then to 101±27N at 90° knee flexion. Medial stability varied from 74±20N at 0° to 170±21N at 90°. There were significant correlations between the sulcus angle and the medial facet angle with medial stability (r=0.78, p<0.0001). These results provide objective evidence relating the changes of femoral profile geometry with knee flexion to patellofemoral stability. Copyright © 2017 Elsevier B.V. All rights reserved.
Oh, Hyunju; Lee, Sangyong; Lee, Kwansub; Jeong, Mugeun
2018-01-01
[Purpose] This study examines the effects of the flexion-distraction technique and the drop technique on disorders and on Ferguson’s angle in female patients with lumbar intervertebral disc herniation. [Subjects and Methods] Thirty female patients with lumbar intervertebral disc herniation were divided into an experimental group (n=15) treated with flexion-distraction and drop techniques and a control group (n=15) treated with spinal decompression therapy. Both groups were treated three times a week over an eight-week period. [Results] In the comparison of changes within each group after treatment, both groups showed statistically significant decreases in disorders and in Ferguson’s angle. [Conclusion] Flexion-distraction and drop techniques may be an effective intervention to improve disorders and Ferguson’s angle in female patients with lumbar intervertebral disc herniation. PMID:29706701
Matsumoto, Tomoyuki; Shibanuma, Nao; Takayama, Koji; Sasaki, Hiroshi; Ishida, Kazunari; Matsushita, Takehiko; Kuroda, Ryosuke; Kurosaka, Masahiro
2016-06-01
Appropriate soft tissue balance is essential for the success of total knee arthroplasty (TKA), and assessment with an offset-type tensor provides useful information about the femorotibial (FT) joint. The purpose of the study was to investigate the relationship between intraoperative soft tissue balance and patellar pressure at both medial and lateral sides. Thirty varus-type osteoarthritis patients who received mobile-bearing posterior-stabilized TKAs were enrolled in the study. Using the tensor, soft tissue balance, including joint component gap and varus ligament balance, was recorded at 0°, 10°, 30°, 60°, 90°, 120°, and 135° with patellofemoral (PF) joint reduction and femoral component placement. Following final prostheses implanted with appropriate insert, the medial and lateral patellar pressures were measured at each flexion angle. A simple regression analysis was performed between each patellar pressure, parameter of soft tissue balance, and postoperative flexion angle. Both lateral and medial patellar pressures increased with flexion. The lateral patellar pressure was significantly higher than the medial patellar pressure at 60°, 90°, and 135° of flexion (p<0.05). The lateral patellar pressure inversely correlated with the varus ligament balance at 60° and 90° of flexion (p<0.05). The lateral patellar pressure at 120° and 135° of flexion inversely correlated with the postoperative flexion angle (p<0.05). Soft tissue balance influenced patellar pressure. In particular, a reduced lateral patellar pressure was found at the lateral laxity at flexion, leading to high postoperative flexion angle. III. Copyright © 2016 Elsevier B.V. All rights reserved.
Velocity of lordosis angle during spinal flexion and extension.
Consmüller, Tobias; Rohlmann, Antonius; Weinland, Daniel; Druschel, Claudia; Duda, Georg N; Taylor, William R
2012-01-01
The importance of functional parameters for evaluating the severity of low back pain is gaining clinical recognition, with evidence suggesting that the angular velocity of lordosis is critical for identification of musculoskeletal deficits. However, there is a lack of data regarding the range of functional kinematics (RoKs), particularly which include the changing shape and curvature of the spine. We address this deficit by characterising the angular velocity of lordosis throughout the thoracolumbar spine according to age and gender. The velocity of lumbar back shape changes was measured using Epionics SPINE during maximum flexion and extension activities in 429 asymptomatic volunteers. The difference between maximum positive and negative velocities represented the RoKs. The mean RoKs for flexion decreased with age; 114°/s (20-35 years), 100°/s (36-50 years) and 83°/s (51-75 years). For extension, the corresponding mean RoKs were 73°/s, 57°/s and 47°/s. ANCOVA analyses revealed that age and gender had the largest influence on the RoKs (p<0.05). The Epionics SPINE system allows the rapid assessment of functional kinematics in the lumbar spine. The results of this study now serve as normative data for comparison to patients with spinal pathology or after surgical treatment.
Measurements of normal joint angles by goniometry in calves.
Sengöz Şirin, O; Timuçin Celik, M; Ozmen, A; Avki, S
2014-01-01
The aim of this study was to establish normal reference values of the forelimb and hindlimb joint angles in normal Holstein calves. Thirty clinically normal Holstein calves that were free of any detectable musculoskeletal abnormalities were included in the study. A standard transparent plastic goniometer was used to measure maximum flexion, maximum extension, and range-of-motion of the shoulder, elbow, carpal, hip, stifle, and tarsal joints. The goniometric measurements were done on awake calves that were positioned in lateral recumbency. The goniometric values were measured and recorded by two independent investigators. As a result of the study it was concluded that goniometric values obtained from awake calves in lateral recumbency were found to be highly consistent and accurate between investigators (p <0.05). The data of this study acquired objective and useful information on the normal forelimb and hindlimb joint angles in normal Holstein calves. Further studies can be done to predict detailed goniometric values from different diseases and compare them.
Kingston, David C; Acker, Stacey M
2018-01-23
In high knee flexion, contact between the posterior thigh and calf is expected to decrease forces on tibiofemoral contact surfaces, therefore, thigh-calf contact needs to be thoroughly characterized to model its effect. This study measured knee angles and intersegmental contact parameters in fifty-eight young healthy participants for six common high flexion postures using motion tracking and a pressure sensor attached to the right thigh. Additionally, we introduced and assessed the reliability of a method for reducing noise in pressure sensor output. Five repetitions of two squatting, two kneeling, and two unilateral kneeling movements were completed. Interactions of posture by sex occurred for thigh-calf and heel-gluteal center of force, and thigh-calf contact area. Center of force in thigh-calf regions was farther from the knee joint center in females, compared to males, during unilateral kneeling (82 and 67 mm respectively) with an inverted relationship in the heel-gluteal region (331 and 345 mm respectively), although caution is advised when generalizing these findings from a young, relatively fit sample to a population level. Contact area was larger in females when compared to males (mean of 155.61 and 137.33 cm 2 across postures). A posture main effect was observed in contact force and sex main effects were present in onset and max angle. Males had earlier onset (121.0°) and lower max angle (147.4°) with onset and max angles having a range between movements of 8° and 3° respectively. There was a substantial total force difference of 139 N between the largest and smallest activity means. Force parameters measured in this study suggest that knee joint contact models need to incorporate activity-specific parameters when estimating loading. Copyright © 2017 Elsevier Ltd. All rights reserved.
Variability of Plyometric and Ballistic Exercise Technique Maintains Jump Performance.
Chandler, Phillip T; Greig, Matthew; Comfort, Paul; McMahon, John J
2018-06-01
Chandler, PT, Greig, M, Comfort, P, and McMahon, JJ. Variability of plyometric and ballistic exercise technique maintains jump performance. J Strength Cond Res 32(6): 1571-1582, 2018-The aim of this study was to investigate changes in vertical jump technique over the course of a training session. Twelve plyometric and ballistic exercise-trained male athletes (age = 23.4 ± 4.6 years, body mass = 78.7 ± 18.8 kg, height = 177.1 ± 9.0 cm) performed 3 sets of 10 repetitions of drop jump (DJ), rebound jump (RJ) and squat jump (SJ). Each exercise was analyzed from touchdown to peak joint flexion and peak joint flexion to take-off. Squat jump was analyzed from peak joint flexion to take-off only. Jump height, flexion and extension time and range of motion, and instantaneous angles of the ankle, knee, and hip joints were measured. Separate 1-way repeated analyses of variance compared vertical jump technique across exercise sets and repetitions. Exercise set analysis found that SJ had lower results than DJ and RJ for the angle at peak joint flexion for the hip, knee, and ankle joints and take-off angle of the hip joint. Exercise repetition analysis found that the ankle joint had variable differences for the angle at take-off, flexion, and extension time for RJ. The knee joint had variable differences for flexion time for DJ and angle at take-off and touchdown for RJ. There was no difference in jump height. Variation in measured parameters across repetitions highlights variable technique across plyometric and ballistic exercises. This did not affect jump performance, but likely maintained jump performance by overcoming constraints (e.g., level of rate coding).
Assessment of tibial rotation and meniscal movement using kinematic magnetic resonance imaging
2014-01-01
Objective This work aimed to assess tibial rotations, meniscal movements, and morphological changes during knee flexion and extension using kinematic magnetic resonance imaging (MRI). Methods Thirty volunteers with healthy knees were examined using kinematic MRI. The knees were imaged in the transverse plane with flexion and extension angles from 0° to 40° and 40° to 0°, respectively. The tibial interior and exterior rotation angles were measured, and the meniscal movement range, height change, and side movements were detected. Results The tibia rotated internally (11.55° ± 3.20°) during knee flexion and rotated externally (11.40° ± 3.0°) during knee extension. No significant differences were observed between the internal and external tibial rotation angles (P > 0.05), between males and females (P > 0.05), or between the left and right knee joints (P > 0.05). The tibial rotation angle with a flexion angle of 0° to 24° differed significantly from that with a flexion angle of 24° to 40° (P < 0.01). With knee flexion, the medial and lateral menisci moved backward and the height of the meniscus increased. The movement range was greater in the anterior horn than in the posterior horn and greater in the lateral meniscus than in the medial meniscus (P < 0.01). During backward movements of the menisci, the distance between the anterior and posterior horns decreased, with the decrease more apparent in the lateral meniscus (P < 0.01). The side movements of the medial and lateral menisci were not obvious, and a smaller movement range was found than that of the forward and backward movements. Conclusion Knee flexion and extension facilitated internal and external tibial rotations, which may be related to the ligament and joint capsule structure and femoral condyle geometry. PMID:25142267
Femoral neck radiography: effect of flexion on visualization.
Garry, Steven C; Jhangri, Gian S; Lambert, Robert G W
2005-06-01
To determine whether flexion improves radiographic visualization of the femoral neck when the femur is externally rotated. Five human femora, with varying neck-shaft and anteversion angles, were measured and immobilized. Degree of flexion required to bring the femoral neck horizontal was measured, varying the rotation. Next, one bone was radiographed in 16 positions, varying rotation in 15 degrees and flexion in 10 degrees increments. Radiographs were presented in randomized blinded fashion to 15 staff radiologists for scoring of femoral neck visualization. Following this, all 5 bones were radiographed in 4 positions of rotation and at 0 degree and 20 degrees flexion, and blinded randomized review of radiographs was repeated. Comparisons between angles and rotations were made using the Mann-Whitney test. The flexion angle required to bring the long axis of the femoral neck horizontal correlated directly with the degree of external rotation (p < 0.05). Visualization of the femoral neck in the extended position progressively deteriorated from 15 degrees internal rotation to 30 degrees external rotation (p < 0.01). However, when 20 degrees flexion was applied to bones in external rotation, visualization significantly improved at 15 degrees (p < 0.05) and 30 degrees (p < 0.01). Flexion of the externally rotated femur can bring the femoral neck into horizontal alignment, and a relatively small amount (20 degrees) of flexion can significantly improve radiographic visualization. This manoeuvre could be useful for radiography of the femoral neck when initial radiographs are inadequate because of external rotation of the leg.
Primary and coupled motions of the native knee in response to applied varus and valgus load.
Gladnick, Brian P; Boorman-Padgett, James; Stone, Kyle; Kent, Robert N; Cross, Michael B; Mayman, David J; Pearle, Andrew D; Imhauser, Carl W
2016-06-01
Knowledge of the complex kinematics of the native knee is a prerequisite for a successful reconstructive procedure. The aim of this study is to describe the primary and coupled motions of the native knee throughout the range of knee flexion, in response to applied varus and valgus loads. Twenty fresh-frozen cadaver knees were affixed to a six degree of freedom robotic arm with a universal force-moment sensor, and loaded with a 4Nm moment in varus and valgus at 0, 15, 30, 45, and 90° of knee flexion. The resulting tibiofemoral angulation, displacement, and rotation were recorded. For each parameter investigated, the knee joint demonstrated more laxity at higher flexion angles. Varus angulation increased progressively from zero (2.0° varus) to 90 (5.2° varus) degrees of knee flexion (p<0.001). Valgus angulation also increased progressively, from zero (1.5° valgus) to 90 (3.9° valgus) degrees of knee flexion (p<0.001). At all flexion angles, the magnitude of tibiofemoral angle deviation was larger with varus than with valgus loading (p<0.05). We conclude that the native knee exhibits small increases in coronal plane laxity as the flexion angle increases, and that the knee has generally more laxity under varus load than with valgus load throughout the Range of Motion (ROM). Larger differences in laxity of more than 2 to 3°, or peak laxity specifically during the range of mid-flexion, were not found in our cadaver model and are not likely to represent normal coronal plane kinematics. Level V, biomechanical cadaveric study. Copyright © 2016 Elsevier B.V. All rights reserved.
The Effects of Walking Workstations on Biomechanical Performance.
Grindle, Daniel M; Baker, Lauren; Furr, Mike; Puterio, Tim; Knarr, Brian; Higginson, Jill
2018-04-03
Prolonged sitting has been associated with negative health effects. Walking workstations have become increasingly popular in the workplace. There is a lack of research on the biomechanical effect of walking workstations. This study analyzed whether walking while working alters normal gait patterns. Nine participants completed four walking trials at 2.4 km·h -1 and 4.0 km·h -1 : baseline walking condition, walking while performing a math task, a reading task, and a typing task. Biomechanical data were collected using standard motion capture procedures. The first maximum vertical ground reaction force, stride width, stride length, minimum toe clearance, peak swing hip abduction and flexion angles, peak swing and stance ankle dorsiflexion and knee flexion angles were analyzed. Differences between conditions were evaluated using analysis of variance tests with Bonferroni correction (p ≤ 0.05). Stride width decreased during the reading task at both speeds. Although other parameters exhibited significant differences when multitasking, these changes were within the normal range of gait variability. It appears that for short periods, walking workstations do not negatively impact gait in healthy young adults.
Influence of input device, work surface angle, and task on spine kinematics.
Riddell, Maureen F; Gallagher, Kaitlin M; McKinnon, Colin D; Callaghan, Jack P
2016-01-01
With the increase of tablet usage in both office and industrial workplaces, it is critical to investigate the influence of tablet usage on spine posture and movement. To quantify spine kinematics while participants interacted with a tablet or desktop computer. Fourteen participants volunteered for this study. Marker clusters were fixed onto body regions to analyze cervical and lumbar spine posture and sampled at 32 Hz (Optotrak Certus, NDI, Waterloo, Canada). Participants sat for one hour in total. Cervical and lumbar median angles and range of motion (10th to 90th % ile angles) were extracted from amplitude probability distribution functions performed on the angle data. Using a sloped desk surface at 15°, compared to a flat desk, influenced cervical flexion (p = 0.0228). Completing the form fill task resulted in the highest degree of cervical flexion (p = 0.0008) compared to the other tasks completed with cervical angles between 6.1°-8.5° higher than emailing and reading respectively. An interaction between device and task (p = 0.0061) was found for relative lumbar median spine angles. Increased lumbar flexion was recorded when using a computer versus a tablet to complete various tasks. Task influenced both cervical and lumbar spine posture with the highest cervical flexion occurring while completing a simulated data entry task. A work surface slope of 15° decreased cervical spine flexion compared to a horizontal work surface slope.
Suzuki, Takashi; Motojima, Sayaka; Saito, Shu; Ishii, Takao; Ryu, Keinosuke; Ryu, Junnosuke; Tokuhashi, Yasuaki
2013-11-01
The type of osteoarthritis and the degree of severity which causes restriction of knee range of motion (ROM) is still largely unknown. The objective of this study was to analyse the location and the degree of cartilage degeneration that affect knee range of motion and the connection, if any, between femorotibial angle (FTA) and knee ROM restriction. Four hundreds and fifty-six knees in 230 subjects with knee osteoarthritis undergoing knee arthroplasty were included. Articular surface was divided into eight sections, and cartilage degeneration was evaluated macroscopically during the operation. Cartilage degeneration was classified into four grades based on the degree of exposure of subchondral bone. A Pearson correlation was conducted between FTA and knee flexion angle to determine whether high a degree of FTA caused knee flexion restriction. A logistic regression analysis was also conducted to detect the locations and levels of cartilage degeneration causing knee flexion restriction. No correlation was found between FTA and flexion angle (r = -0.08). Flexion angle was not restricted with increasing FTA. Logistic regression analysis showed significant correlation between restricted knee ROM and levels of knee cartilage degeneration in the patella (odds ratio (OR) = 1.77; P = 0.01), the lateral femoral condyle (OR = 1.62; P = 0.03) and the posterior medial femoral condyle (OR = 1.80; P = 0.03). For clinical relevance, soft tissue release and osteophyte resection around the patella, lateral femoral condyle and posterior medial femoral condyle might be indicated to obtain a higher degree of knee flexion angle.
Gender difference in mobile phone use and the impact of digital device exposure on neck posture.
Guan, Xiaofei; Fan, Guoxin; Chen, Zhengqi; Zeng, Ying; Zhang, Hailong; Hu, Annan; Gu, Guangfei; Wu, Xinbo; Gu, Xin; He, Shisheng
2016-11-01
This cross-sectional study aimed to identify gender differences in the cervical postures when young adults were using mobile phones, as well as the correlations between the postures and the digital devices use (computer and mobile phone). Questionnaires regarding the habits of computer and mobile phone use were administrated to 429 subjects aged from 17 to 33 years old (19.75 ± 2.58 years old). Subjects were instructed to stand habitually and use a mobile phone as in daily life; the sagittal head and cervical postures were measured by head flexion, neck flexion angle and gaze angle. Male participants had a significantly larger head flexion angle (96.41° ± 12.23° vs. 93.57° ± 12.62°, p = 0.018) and neck flexion angle (51.92° ± 9.55° vs. 47.09° ± 9.45°, p < 0.001) than females. There were significant differences in head (F = 3.62, p = 0.014) and neck flexion (F = 3.99, p = 0.009) between different amounts of computer use. Practitioner Summary: We investigated possible gender differences in head and neck postures of young adults using mobile phones, as well as the potential correlations between these postures and digital device use. We found that males displayed larger head and neck flexion angles than females, which were associated with the amount of computer use.
Yang, Zhaochun; Wickwire, Alexis C; Debski, Richard E
2010-11-01
Recent clinical evidence has suggested that tasks performed in kneeling or squatting postures place the knee at a higher risk for injury because loads across the knee might overload the ligaments. The objective of this study was to develop a subject-specific model of the knee that is kinematically driven to predict the forces in the major ligaments at high flexion angles. The geometry of the femur, tibia, and fibula and the load-elongation curves representing the structural properties of the ACL, PCL, LCL, and MCL served as inputs to the model, which represented each ligament as a nonlinear elastic spring. To drive the model, kinematic data was obtained while loads were applied to the same cadaveric knee at four flexion angles. The force in each ligament during the recorded kinematic data allowed an optimization procedure to determine the location of the ligament attachment sites on each bone and their reference lengths. The optimization procedure could successfully minimize the differences between the experimental and predicted forces only when the kinematics at 90°, 120°, and 140° of flexion were utilized. This finding suggests that the ligaments at the knee function differently at high-flexion angles compared to low flexion angles and separate models must be used to examine each range of motion. In the future, the novel experimental and computational methodology will be used to construct additional models and additional knee kinematics will be input to help elucidate mechanisms of injury during tasks performed in kneeling or squatting postures.
Tang, Jing; Thorhauer, Eric; Marsh, Chelsea; Fu, Freddie H.
2013-01-01
Purpose Femoral tunnel angle (FTA) has been proposed as a metric for evaluating whether ACL reconstruction was performed anatomically. In clinic, radiographic images are typically acquired with an uncertain amount of internal/external knee rotation. The extent to which knee rotation will influence FTA measurement is unclear. Furthermore, differences in FTA measurement between the two common positions (0° and 45° knee flexion) have not been established. The purpose of this study was to investigate the influence of knee rotation on FTA measurement after ACL reconstruction. Methods Knee CT data from 16 subjects were segmented to produce 3D bone models. Central axes of tunnels were identified. The 0° and 45° flexion angles were simulated. Knee internal/external rotations were simulated in a range of ±20°. FTA was defined as the angle between the tunnel axis and femoral shaft axis, orthogonally projected into the coronal plane. Results Femoral tunnel angle was positively/negatively correlated with knee rotation angle at 0°/45° knee flexion. At 0° knee flexion, FTA for anterio-medial (AM) tunnels was significantly decreased at 20° of external knee rotation. At 45° knee flexion, more than 16° external or 19° internal rotation significantly altered FTA measurements for single-bundle tunnels; smaller rotations (±9° for AM, ±5° for PL) created significant errors in FTA measurements after double-bundle reconstruction. Conclusion Femoral tunnel angle measurements were correlated with knee rotation. Relatively small imaging malalignment introduced significant errors with knee flexed 45°. This study supports using the 0° flexion position for knee radiographs to reduce errors in FTA measurement due to knee internal/external rotation. Level of evidence Case–control study, Level III. PMID:23589127
Cho, Misuk
2015-06-01
[Purpose] This study aimed to identify correlations among pelvic positions and differences in lower extremity joint angles during walking in female university students. [Subjects] Thirty female university students were enrolled and their pelvic positions and differences in lower extremity joint angles were measured. [Methods] Pelvic position, pelvic torsion, and pelvic rotation were assessed using the BackMapper. In addition, motion analysis was performed to derive differences between left and right flexion, abduction, and external rotation ranges of hip joints; flexion, abduction, and external rotation ranges of knee joints; and dorsiflexion, inversion, and abduction ranges of ankle joints, according to X, Y, and Z-axes. [Results] Pelvic position was found to be positively correlated with differences between left and right hip flexion (r=0.51), hip abduction (r=0.62), knee flexion (r=0.45), knee abduction (r=0.42), and ankle inversion (r=0.38). In addition, the difference between left and right hip abduction showed a positive correlation with difference between left and right ankle dorsiflexion (r=0.64). Moreover, differences between left and right knee flexion exhibited positive correlations with differences between left and right knee abduction (r=0.41) and ankle inversion (r=0.45). [Conclusion] Bilateral pelvic tilt angles are important as they lead to bilateral differences in lower extremity joint angles during walking.
Range of Hip Joint Motion Is Correlated With MRI-Verified Cam Deformity in Adolescent Elite Skiers
Agnvall, Cecilia; Swärd Aminoff, Anna; Todd, Carl; Jonasson, Pall; Thoreson, Olof; Swärd, Leif; Karlsson, Jon; Baranto, Adad
2017-01-01
Background: Radiologically verified cam-type femoroacetabular impingement (FAI) has been shown to correlate with reduced internal rotation, reduced passive hip flexion, and a positive anterior impingement test. Purpose: To validate how a clinical examination of the hip joint correlates with magnetic resonance imaging (MRI)–verified cam deformity in adolescents. Study Design: Cross-sectional study; Level of evidence, 3. Methods: The sample group consisted of 102 adolescents with the mean age 17.7 ± 1.4 years. The hip joints were examined using MRI for measurements of the presence of cam (α-angle ≥55°) and clinically for range of motion (ROM) in both supine and sitting positions. The participants were divided into a cam and a noncam group based on the results of the MRI examination. Passive hip flexion, internal rotation, anterior impingement, and the FABER (flexion, abduction, and external rotation) test were used to test both hips in the supine position. With the participant sitting, the internal/external rotation of the hip joint was measured in 3 different positions of the pelvis (neutral, maximum anteversion, and retroversion) and lumbar spine (neutral, maximum extension, and flexion). Results: Differences were found between the cam and noncam groups in terms of the anterior impingement test (right, P = .010; left, P = .006), passive supine hip flexion (right: mean, 5°; cam, 117°; noncam, 122° [P = .05]; and left: mean, 8.5°; cam, 116°; noncam, 124.5° [P = .001]), supine internal rotation (right: mean, 4.9°; cam, 24°; noncam, 29° [P = .022]; and left: mean, 4.8°; cam, 26°; noncam, 31° [P = .028]), sitting internal rotation with the pelvis and lumbar spine in neutral (right: mean, 7.95°; cam, 29°; noncam, 37° [P = .001]; and left: mean, 6.5°; cam, 31.5°; noncam, 38° [P = .006]), maximum anteversion of the pelvis and extension of the lumbar spine (right: mean, 5.2°; cam, 20°; noncam, 25° [P = .004]; and left: mean, 5.85°; cam, 20.5; noncam, 26.4° [P = .004]), and maximum retroversion of the pelvis and flexion of the spine (right: mean, 8.4°; cam, 32.5°; noncam, 41° [P = .001]; and left: mean, 6.2°; cam, 36°; noncam, 42.3° [P = .012]). The cam group had reduced ROM compared with the noncam group in all clinical ROM measures. Conclusion: The presence of cam deformity on MRI correlates with reduced internal rotation in the supine and sitting positions, passive supine hip flexion, and the impingement test in adolescents. PMID:28695136
NASA Astrophysics Data System (ADS)
Straton, Alexandru; Gidu, Diana Victoria; Micu, Alexandru
2015-02-01
Poor lateral flexor muscle strength can be an important source of lumbar/thoracic back pain in women. The purpose of this study was to evaluate pelvic stabilization (PS) and no pelvic stabilization (NoPS) lateral flexion strength exercise training on the development of isolated right and left lateral flexion strength. Isometric torque of the isolated right and left lateral flexion muscles was measured at two positions (0° and 30° opposed angle range of motion) on 42 healthy women before and after 8 weeks of PS and NoPS lateral flexion strength exercise training. Subjects were assigned in three groups, the first (n=14) trained 3 times/week with PS lateral flexion strength exercise, the second (n=14) trained 3 times/week with NoPS lateral flexion strength exercise and the third (control, n=14) did not train. Post training isometric strength values describing PS and NoPS lateral flexion strength improved in greater extent for the PS lateral flexion strength exercise group and in lesser extent for the NoPS lateral flexion strength exercise group, in both angles (p<0.05) relative to controls. These data indicate that the most effective way of training the spine lateral flexion muscles is PS lateral flexion strength exercises; NoPS lateral flexion strength exercises can be an effective way of training for the spine lateral flexion muscles, if there is no access to PS lateral flexion strength training machines.
Marchetti, Daniel Cole; Phelps, Brian M; Dahl, Kimi D; Slette, Erik L; Mikula, Jacob D; Dornan, Grant J; Bucci, Gabriella; Turnbull, Travis Lee; Singleton, Steven B
2017-10-01
To directly compare effectiveness of the inside-out and all-inside medial meniscal repair techniques in restoring native contact area and contact pressure across the medial tibial plateau at multiple knee flexion angles. Twelve male, nonpaired (n = 12), fresh-frozen human cadaveric knees underwent a series of 5 consecutive states: (1) intact medial meniscus, (2) MCL tear and repair, (3) simulated bucket-handle longitudinal tear of the medial meniscus, (4) inside-out meniscal repair, and (5) all-inside meniscal repair. Knees were loaded with a 1,000-N axial compressive force at 5 knee flexion angles (0°, 30°, 45°, 60°, 90°), and contact area, mean contact pressure, and peak contact pressure were calculated using thin film pressure sensors. No significant differences were observed between the inside-out and all-inside repair techniques at any flexion angle for contact area, mean contact pressure, and peak contact pressure (all P > .791). Compared with the torn meniscus state, inside-out and all-inside repair techniques resulted in increased contact area at all flexion angles (all P < .005 and all P < .037, respectively), decreased mean contact pressure at all flexion angles (all P < .007 and all P < .001, respectively) except for 0° (P = .097 and P = .39, respectively), and decreased peak contact pressure at all flexion angles (all P < .001, all P < .001, respectively) except for 0° (P = .080 and P = .544, respectively). However, there were significant differences in contact area and peak contact pressure between the intact state and inside-out technique at angles ≥45° (all P < .014 and all P < .032, respectively). Additionally, there were significant differences between the intact state and all-inside technique in contact area at 60° and 90° and peak contact pressure at 90° (both P < .005 and P = .004, respectively). Median values of intact contact area, mean contact pressure, and peak contact pressure over the tested flexion angles ranged from 498 to 561 mm 2 , 786 to 997 N/mm 2 , and 1,990 to 2,215 N/mm 2 , respectively. Contact area, mean contact pressure, and peak contact pressure were not significantly different between the all-inside and inside-out repair techniques at any tested flexion angle. Both techniques adequately restored native meniscus biomechanics near an intact level. An all-inside repair technique provided similar, native-state-restoring contact mechanics compared with an inside-out repair technique for the treatment of displaced bucket-handle tears of the medial meniscus. Thus, both techniques may adequately decrease the likelihood of cartilage degeneration. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Freedman, Benjamin R; Sheehan, Frances T; Lerner, Amy L
2015-10-01
Several factors are believed to contribute to patellofemoral joint function throughout knee flexion including patellofemoral (PF) kinematics, contact, and bone morphology. However, data evaluating the PF joint in this highly flexed state have been limited. Therefore, the purpose of this study was to evaluate patellofemoral contact and alignment in low (0°), moderate (60°), and deep (140°) knee flexion, and then correlate these parameters to each other, as well as to femoral morphology. Sagittal magnetic resonance images were acquired on 14 healthy female adult knees (RSRB approved) using a 1.5 T scanner with the knee in full extension, mid-flexion, and deep flexion. The patellofemoral cartilage contact area, lateral contact displacement (LCD), cartilage thickness, and lateral patellar displacement (LPD) throughout flexion were defined. Intra- and inter-rater repeatability measures were determined. Correlations between patellofemoral contact parameters, alignment, and sulcus morphology were calculated. Measurement repeatability ICCs ranged from 0.94 to 0.99. Patellofemoral cartilage contact area and thickness, LCD, and LPD were statistically different throughout all levels of flexion (p<0.001). The cartilage contact area was correlated to LPD, cartilage thickness, sulcus angle, and epicondylar width (r=0.47-0.72, p<0.05). This study provides a comprehensive analysis of the patellofemoral joint throughout its range of motion. This study agrees with past studies that investigated patellofemoral measures at a single flexion angle, and provides new insights into the relationship between patellofemoral contact and alignment at multiple flexion angles. The study provides a detailed analysis of the patellofemoral joint in vivo, and demonstrates the feasibility of using standard clinical magnetic resonance imaging scanners to image the knee joint in deep flexion. Copyright © 2015 Elsevier B.V. All rights reserved.
Modelling knee flexion effects on joint power absorption and adduction moment.
Nagano, Hanatsu; Tatsumi, Ichiroh; Sarashina, Eri; Sparrow, W A; Begg, Rezaul K
2015-12-01
Knee osteoarthritis is commonly associated with ageing and long-term walking. In this study the effects of flexing motions on knee kinetics during stance were simulated. Extended knees do not facilitate efficient loading. It was therefore, hypothesised that knee flexion would promote power absorption and negative work, while possibly reducing knee adduction moment. Three-dimensional (3D) position and ground reaction forces were collected from the right lower limb stance phase of one healthy young male subject. 3D position was sampled at 100 Hz using three Optotrak Certus (Northern Digital Inc.) motion analysis camera units, set up around an eight metre walkway. Force plates (AMTI) recorded ground reaction forces for inverse dynamics calculations. The Visual 3D (C-motion) 'Landmark' function was used to change knee joint positions to simulate three knee flexion angles during static standing. Effects of the flexion angles on joint kinetics during the stance phase were then modelled. The static modelling showed that each 2.7° increment in knee flexion angle produced 2.74°-2.76° increments in knee flexion during stance. Increased peak extension moment was 6.61 Nm per 2.7° of increased knee flexion. Knee flexion enhanced peak power absorption and negative work, while decreasing adduction moment. Excessive knee extension impairs quadriceps' power absorption and reduces eccentric muscle activity, potentially leading to knee osteoarthritis. A more flexed knee is accompanied by reduced adduction moment. Research is required to determine the optimum knee flexion to prevent further damage to knee-joint structures affected by osteoarthritis. Copyright © 2015 Elsevier B.V. All rights reserved.
Kim, Si-hyun; Kwon, Oh-yun; Yi, Chung-hwi; Cynn, Heon-seock; Ha, Sung-min; Park, Kyue-nam
2014-01-01
Limited hip flexion may lead to a poor lumbopelvic motion during seated active hip flexion in people with low-back pain (LBP). The purpose of this study was to compare lumbopelvic motion during seated hip flexion between subjects with and without LBP accompanying limited hip flexion. Fifteen patients with LBP accompanying limited hip flexion and 16 healthy subjects were recruited. The subjects performed seated hip flexion with the dominant leg three times. A three-dimensional motion-analysis system was used to measure lumbopelvic motion during seated hip flexion. During seated active hip flexion, the angle of hip flexion was significantly lower in patients with LBP accompanying limited hip flexion (17.4 ± 4.4 in the LBP group, 20.8 ± 2.6 in the healthy group; t = 2.63, p = 0.014). The angle of the lumbar flexion (4.8 ± 2.2 in the LBP group, 2.6 ± 2.0 in the healthy group; t = -2.96, p = 0.006) and posterior pelvic tilting (5.0 ± 2.6 in the LBP group, 2.9 ± 2.0 in the healthy group; t = 2.48 p = 0.019), however, were significantly greater in patients with this condition. The results of this study suggest that limited hip flexion in LBP can contribute to excessive lumbar flexion and posterior pelvic tilting during hip flexion in the sitting position. Further studies are required to confirm whether improving the hip flexion range of motion can reduce excessive lumbar flexion in patients with LBP accompanying limited hip flexion.
Schmalz, Thomas; Pröbsting, Eva; Auberger, Roland; Siewert, Gordon
2016-04-01
The microprocessor-controlled leg orthosis C-Brace enables patients with paretic or paralysed lower limb muscles to use dampened knee flexion under weight-bearing and speed-adapted control of the swing phase. The objective of the present study was to investigate the new technical functions of the C-Brace orthosis, based on biomechanical parameters. The study enrolled six patients. The C-Brace orthosis is compared with conventional leg orthoses (four stance control orthoses, two locked knee-ankle-foot orthoses) using biomechanical parameters of level walking, descending ramps and descending stairs. Ground reaction forces, joint moments and kinematic parameters were measured for level walking as well as ascending and descending ramps and stairs. With the C-Brace, a nearly natural stance phase knee flexion was measured during level walking (mean value 11° ± 5.6°). The maximum swing phase knee flexion angle of the C-Brace approached the normal value of 65° more closely than the stance control orthoses (66° ± 8.5° vs 74° ± 6.4°). No significant differences in the joint moments were found between the C-Brace and stance control orthosis conditions. In contrast to the conventional orthoses, all patients were able to ambulate ramps and stairs using a step-over-step technique with C-Brace (flexion angle 64.6° ± 8.2° and 70.5° ± 12.4°). The results show that the functions of the C-Brace for situation-dependent knee flexion under weight bearing have been used by patients with a high level of confidence. The functional benefits of the C-Brace in comparison with the conventional orthotic mechanisms could be demonstrated most clearly for descending ramps and stairs. The C-Brace orthosis is able to combine improved orthotic function with sustained orthotic safety. © The International Society for Prosthetics and Orthotics 2014.
Comparison of goniometric measurements of the stifle joint in seven breeds of normal dogs.
Sabanci, Seyyid S; Ocal, Mehmet K
2016-05-18
To compare the goniometric measurements of the stifle joint in seven dog breeds, and to determine the relationship among goniometric measurements, age, body weight, tibial plateau angle, crus and thigh circumferences, and widths of quadriceps, hamstring, and gastrocnemius muscles in healthy dogs. We used a total of 126 dogs from seven different breeds, and recorded the angle of the stifle joint at standing, extension, and flexion together with the range of motion (ROM). The circumferences of the thigh and crus were also measured. Mediolateral radiographic projections of the tibia and the femur were obtained from the dogs, and the tibial plateau angles, as well as the widths of quadriceps, hamstring, and gastrocnemius muscles, were measured from these images. Neither the sex of the dog nor the differences in the side measured affected the goniometric measurements of the stifle joint. The standing, extension, flexion, and ROM angles were different among the breeds. The standard deviations of the standing and extension angles were small relative to their means, but the standard deviations of the flexion angle were large relative to their means in all breeds. Body weight and muscular measurements were the most influential factors on the stifle flexion angle and ROM. Breed differences, body weights, and muscle mass should be taken into consideration during assessment of the stifle function using goniometric measurements.
Kim, Juseung; Park, Minchul
2016-09-01
[Purpose] This study compared abdominal and hip extensor muscle activity during a bridge exercise with various knee joint angles. [Subjects and Methods] Twenty-two healthy male subjects performed a bridge exercise in which the knee joint angle was altered. While subjects performed the bridge exercise, external oblique, internal oblique, gluteus maximus, and semitendinosus muscle activity was measured using electromyography. [Results] The bilateral external and internal oblique muscle activity was significantly higher at 0° knee flexion compared to 120°, 90°, and 60°. The bilateral gluteus maximus muscle activity was significantly different at 0° of knee flexion compared to 120°, 90°, and 60°. The ipsilateral semitendinosus muscle activity was significantly increased at 90° and 60° of knee flexion compared to 120°, and significantly decreased at 0° knee flexion compared with 120°, 90°, and 60°. The contralateral semitendinosus muscle activity was significantly higher at 60° of knee flexion than at 120°, and significantly higher at 0° of knee flexion than at 120°, 90°, and 60°. [Conclusion] Bridge exercises performed with knee flexion less than 90° may be used to train the ipsilateral semitendinosus. Furthermore, bridge exercise performed with one leg may be used to train abdominal and hip extensor muscles.
Lower Extremity Kinematics During a Drop Jump in Individuals With Patellar Tendinopathy
Rosen, Adam B.; Ko, Jupil; Simpson, Kathy J.; Kim, Seock-Ho; Brown, Cathleen N.
2015-01-01
Background: Patellar tendinopathy (PT) is a common degenerative condition in physically active populations. Knowledge regarding the biomechanics of landing in populations with symptomatic PT is limited, but altered mechanics may play a role in the development or perpetuation of PT. Purpose: To identify whether study participants with PT exhibited different landing kinematics compared with healthy controls. Study Design: Controlled laboratory study. Methods: Sixty recreationally active participants took part in this study; 30 had current signs and symptoms of PT, including self-reported pain within the patellar tendon during loading activities for at least 3 months and ≤80 on the Victorian Institute of Sport Assessment Scale–Patella (VISA-P). Thirty healthy participants with no history of PT or other knee joint pathology were matched by sex, age, height, and weight. Participants completed 5 trials of a 40-cm, 2-legged drop jump followed immediately by a 50% maximum vertical jump. Dependent variables of interest included hip, knee, and ankle joint angles at initial ground contact, peak angles, and maximum angular displacements during the landing phase in 3 planes. Independent-samples t tests (P ≤ .05) were utilized to compare the joint angles and angular displacements between PT and control participants. Results: Individuals with PT displayed significantly decreased peak hip (PT, 59.2° ± 14.6°; control, 67.2° ± 13.9°; P = .03) and knee flexion angles (PT, 74.8° ± 13.2°; control, 82.5° ± 9.0°; P = .01) compared with control subjects. The PT group displayed decreased maximum angular displacement in the sagittal plane at the hip (PT, 49.3° ± 10.8°; control, 55.2° ± 11.4°; P = .04) and knee (PT, 71.6° ± 8.4°; control, 79.7° ± 8.3°; P < .001) compared with the control group. Conclusion: Participants with PT displayed decreased maximum flexion and angular displacement in the sagittal plane, at both the knee and the hip. The altered movement patterns in those with PT may be perpetuating symptoms associated with PT and could be due to the contributions of the rectus femoris during dynamic movement. Clinical Relevance: Based on kinematic alterations in symptomatic participants, rehabilitation efforts may benefit from focusing on both the knee and the hip to treat symptoms associated with PT. PMID:26665034
Leppänen, Mari; Pasanen, Kati; Kujala, Urho M; Vasankari, Tommi; Kannus, Pekka; Äyrämö, Sami; Krosshaug, Tron; Bahr, Roald; Avela, Janne; Perttunen, Jarmo; Parkkari, Jari
2017-02-01
Few prospective studies have investigated the biomechanical risk factors of anterior cruciate ligament (ACL) injury. To investigate the relationship between biomechanical characteristics of vertical drop jump (VDJ) performance and the risk of ACL injury in young female basketball and floorball players. Cohort study; Level of evidence, 3. At baseline, a total of 171 female basketball and floorball players (age range, 12-21 years) participated in a VDJ test using 3-dimensional motion analysis. The following biomechanical variables were analyzed: (1) knee valgus angle at initial contact (IC), (2) peak knee abduction moment, (3) knee flexion angle at IC, (4) peak knee flexion angle, (5) peak vertical ground-reaction force (vGRF), and (6) medial knee displacement. All new ACL injuries, as well as match and training exposure, were then recorded for 1 to 3 years. Cox regression models were used to calculate hazard ratios (HRs) and 95% CIs. Fifteen new ACL injuries occurred during the study period (0.2 injuries/1000 player-hours). Of the 6 factors considered, lower peak knee flexion angle (HR for each 10° increase in knee flexion angle, 0.55; 95% CI, 0.34-0.88) and higher peak vGRF (HR for each 100-N increase in vGRF, 1.26; 95% CI, 1.09-1.45) were the only factors associated with increased risk of ACL injury. A receiver operating characteristic (ROC) curve analysis showed an area under the curve of 0.6 for peak knee flexion and 0.7 for vGRF, indicating a failed-to-fair combined sensitivity and specificity of the test. Stiff landings, with less knee flexion and greater vGRF, in a VDJ test were associated with increased risk of ACL injury among young female basketball and floorball players. However, although 2 factors (decreased peak knee flexion and increased vGRF) had significant associations with ACL injury risk, the ROC curve analyses revealed that these variables cannot be used for screening of athletes.
Malfait, Bart; Dingenen, Bart; Smeets, Annemie; Staes, Filip; Pataky, Todd; Robinson, Mark A; Vanrenterghem, Jos; Verschueren, Sabine
2016-01-01
The purpose was to assess if variation in sagittal plane landing kinematics is associated with variation in neuromuscular activation patterns of the quadriceps-hamstrings muscle groups during drop vertical jumps (DVJ). Fifty female athletes performed three DVJ. The relationship between peak knee and hip flexion angles and the amplitude of four EMG vectors was investigated with trajectory-level canonical correlation analyses over the entire time period of the landing phase. EMG vectors consisted of the {vastus medialis(VM),vastus lateralis(VL)}, {vastus medialis(VM),hamstring medialis(HM)}, {hamstring medialis(HM),hamstring lateralis(HL)} and the {vastus lateralis(VL),hamstring lateralis(HL)}. To estimate the contribution of each individual muscle, linear regressions were also conducted using one-dimensional statistical parametric mapping. The peak knee flexion angle was significantly positively associated with the amplitudes of the {VM,HM} and {HM,HL} during the preparatory and initial contact phase and with the {VL,HL} vector during the peak loading phase (p<0.05). Small peak knee flexion angles were significantly associated with higher HM amplitudes during the preparatory and initial contact phase (p<0.001). The amplitudes of the {VM,VL} and {VL,HL} were significantly positively associated with the peak hip flexion angle during the peak loading phase (p<0.05). Small peak hip flexion angles were significantly associated with higher VL amplitudes during the peak loading phase (p = 0.001). Higher external knee abduction and flexion moments were found in participants landing with less flexed knee and hip joints (p<0.001). This study demonstrated clear associations between neuromuscular activation patterns and landing kinematics in the sagittal plane during specific parts of the landing. These findings have indicated that an erect landing pattern, characterized by less hip and knee flexion, was significantly associated with an increased medial and posterior neuromuscular activation (dominant hamstrings medialis activity) during the preparatory and initial contact phase and an increased lateral neuromuscular activation (dominant vastus lateralis activity) during the peak loading phase.
Lorbach, Olaf; Zumbansen, Nikolaus; Kieb, Matthias; Efe, Turgay; Pizanis, Antonius; Kohn, Dieter; Haupert, Alexander
2018-04-01
Objective evaluation of the optimal graft tension angle to fully restore patellofemoral contact pressure in reconstruction of the medial patellofemoral ligament (MPFL) in comparison to the native knee. Twelve cadaveric knee specimens were fixed in a custom-made fixation device. A sensitive pressure film (Tekscan) was fixed in the patellofemoral joint, and patellofemoral contact pressure was assessed during a dynamic flexion movement from 0° to 90°. The MPFL was cut and measurements were repeated. Reconstruction of the MPFL was performed with the gracilis tendon subsequently fixed in the femur at 15°, 30°, 45°, 60°, 75°, and 90° of knee flexion under controlled tension (2 N). The sequence of the flexion angles was alternated. Pressure measurements were repeated after every fixation of the graft. No significant differences were seen in the overall patellofemoral contact pressure compared to the native knee (P > .05). However, medial patellofemoral pressure showed a significant increased patellofemoral contact pressure after MPFL reconstruction at a knee flexion angle during graft fixation of 15° (P = .027), 45° (P = .050, P = .044), and 75° (P = .039). Moreover, proximal/distal patellofemoral contact pressure revealed a significantly reduced contact pressure at 15° (P = .003), 30° (P = .009), 45° (P = .025), 75° (P = .021), and 90° (P = .022) of flexion distal after MPFL reconstruction compared with the intact knee. Lateral patellofemoral contact pressure was significantly reduced in all performed reconstructions (P < .05). The flexion angle during graft fixation for MPFL reconstruction did not have a significant impact on the overall patellofemoral contact pressure. However, selective medial, proximal, distal, and lateral patellofemoral contact pressure was significantly altered for all reconstructions. Fixation of the MPFL graft at 60° of flexion was able to most closely restore patellofemoral contact pressure compared with the intact knee. Based on the findings of the present study, fixation of the graft in anatomic reconstruction of the MPFL should be considered in 60° of flexion under low tension (2 N) to most closely restore patellofemoral contact pressure compared with the native knee. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Hu, Boyi; Ning, Xiaopeng; Dai, Fei; Almuhaidib, Ibrahim
2016-09-01
Uneven ground surface is a common occupational injury risk factor in industries such as agriculture, fishing, transportation and construction. Studies have shown that antero-posteriorly slanted ground surfaces could reduce spinal stability and increase the risk of falling. In this study, the influence of antero-posteriorly slanted ground surfaces on lumbar flexion-relaxation responses was investigated. Fourteen healthy participants performed sagittally symmetric and asymmetric trunk bending motions on one flat and two antero-posteriorly slanted surfaces (-15° (uphill facing) and 15° (downhill facing)), while lumbar muscle electromyography and trunk kinematics were recorded. Results showed that standing on a downhill facing slanted surface delays the onset of lumbar muscle flexion-relaxation phenomenon (FRP), while standing on an uphill facing ground causes lumbar muscle FRP to occur earlier. In addition, compared to symmetric bending, when performing asymmetric bending, FRP occurred earlier on the contralateral side of lumbar muscles and significantly smaller maximum lumbar flexion and trunk inclination angles were observed. Practitioner Summary: Uneven ground surface is a common risk factor among a number of industries. In this study, we investigated the influence of antero-posteriorly slanted ground surface on trunk biomechanics during trunk bending. Results showed the slanted surface alters the lumbar tissue load-sharing mechanism in both sagittally symmetric and asymmetric bending.
Shi, Xiaojun; Shen, Bin; Kang, Pengde; Yang, Jing; Zhou, Zongke; Pei, Fuxing
2013-12-01
To evaluate and quantify the effect of the tibial slope on the postoperative maximal knee flexion and stability in the posterior-stabilized total knee arthroplasty (TKA). Fifty-six patients (65 knees) who had undergone TKA with the posterior-stabilized prostheses were divided into the following 3 groups according to the measured tibial slopes: Group 1: ≤4°, Group 2: 4°-7° and Group 3: >7°. The preoperative range of the motion, the change in the posterior condylar offset, the elevation of the joint line, the postoperative tibiofemoral angle and the preoperative and postoperative Hospital for Special Surgery (HSS) scores were recorded. The tibial anteroposterior translation was measured using the Kneelax 3 Arthrometer at both the 30° and the 90° flexion angles. The mean values of the postoperative maximal knee flexion were 101° (SD 5), 106° (SD 5) and 113° (SD 9) in Groups 1, 2 and 3, respectively. A significant difference was found in the postoperative maximal flexion between the 3 groups (P < 0.001). However, no significant differences were found between the 3 groups in the postoperative HSS scores, the changes in the posterior condylar offset, the elevation of the joint line or the tibial anteroposterior translation at either the 30° or the 90° flexion angles. A 1° increase in the tibial slope resulted in a 1.8° flexion increment (r = 1.8, R (2) = 0.463, P < 0.001). An increase in the posterior tibial slope can significantly increase the postoperative maximal knee flexion. The tibial slope with an appropriate flexion and extension gap balance during the operation does not affect the joint stability.
The crunch factor's role in golf-related low back pain.
Cole, Michael H; Grimshaw, Paul N
2014-05-01
The golf swing exposes the spine to complex torsional, compressive, and shearing loads that increase a player's risk of injury. The crunch factor (CF) has been described as a measure to evaluate the risk of low back injuries in golfers and is based on the notion that lateral flexion and axial trunk rotation jointly contribute to spinal degeneration. However, few studies have evaluated the appropriateness of this measure in golfers with low back pain (LBP). To objectively examine the usefulness of the CF as a measure for assessing the risk of low back injury in golfers. Field-based research using a cross-sectional design. This research used three-dimensional motion analysis to assess the golf swings of 12 golfers with LBP and 15 asymptomatic controls. Three-dimensional kinematics were derived using Vicon Motus, and the CF was calculated as the instantaneous product of axial trunk rotation velocity and lateral trunk flexion angle. Maximum CFs and their timings were not significantly different between the symptomatic and asymptomatic groups. Furthermore, for those golfers who produced higher CFs (irrespective of the group), the increased magnitude could not be attributed to an increased axial angular trunk velocity or lateral flexion angle, but rather to a concomitant increase in both of these variables. The findings suggested that although the fundamental concepts that underpin the CF seem sensible, this measure does not appear to be sensitive enough to distinguish golfers with LBP from the asymptomatic players. Copyright © 2014 Elsevier Inc. All rights reserved.
Kim, Kew-Wan; Lim, Bee-Oh
2014-11-01
Although numerous studies have demonstrated the relationship between maturation and lower extremity biomechanics during landing in team sport athletes, we are presently uninformed of any research that examined the single-legged drop landing biomechanics of gymnasts. The purpose of this study is to investigate the effects of the menarcheal age on the lower extremity biomechanics during a single-legged drop landing in female artistic elite gymnasts. Twenty-two female artistic elite gymnasts, between 9 and 36 years of age, participated in this study. The participants were divided into two groups pre- (n = 11) and post- (n = 11) menarche and asked to perform a single-legged drop landing on top of a 30 cm platform and land on a force plate. The statistical analysis consisted of the multivariate analysis with the level of significance set at p < 0.05. The post-menarche group showed a decrease in their maximum knee flexion angle and increase in their maximum knee abduction angle, maximum internal tibial rotation angle, maximum knee abduction moment, and hamstring-quadriceps muscle activity ratio compared with the pre-menarche group during the single-legged drop landing. The post-menarche group showed an increased noncontact anterior cruciate ligament injury risk, due to their greater knee loads, compared with the pre-menarche group.
Seymore, Kayla D; Cameron, Sarah E; Kaplan, Jonathan T; Ramsay, John W; Brown, Tyler N
2017-12-08
This study quantified how a dual cognitive task impacts lower limb biomechanics during anticipated and unanticipated single-leg cuts with body borne load. Twenty-four males performed anticipated and unanticipated cuts with and without a dual cognitive task with three load conditions: no load (∼6 kg), medium load (15% of BW), and heavy load (30% of BW). Lower limb biomechanics were submitted to a repeated measures linear mixed model to test the main and interaction effects of load, anticipation, and dual task. With body borne load, participants increased peak stance (PS) hip flexion (p = .004) and hip internal rotation (p = .001) angle, and PS hip flexion (p = .001) and internal rotation (p = .018), and knee flexion (p = .016) and abduction (p = .001) moments. With the dual task, participants decreased PS knee flexion angle (p < .001) and hip flexion moment (p = .027), and increased PS knee external rotation angle (p = .034). During the unanticipated cut, participants increased PS hip (p = .040) and knee flexion angle (p < .001), and decreased PS hip adduction (p = .001), and knee abduction (p = .005) and external rotation (p = .026) moments. Adding body borne load produces lower limb biomechanical adaptations thought to increase risk of musculoskeletal injury, but neither anticipation nor dual task exaggerated those biomechanical adaptations. With a dual task, participants adopted biomechanics known to increase injury risk; whereas, participants used lower limb biomechanics thought to decrease injury risk during unanticipated cuts. Copyright © 2017 Elsevier Ltd. All rights reserved.
Output of skeletal muscle contractions. a study of isokinetic plantar flexion in athletes.
Fugl-Meyer, A R; Mild, K H; Hörnsten, J
1982-06-01
Maximum torques, total work and mean power of isokinetic plantar flexions were measured with simultaneous registrations. The integrated electromyograms (iEMG) were obtained by surface electrodes from all three heads of the m. triceps surae. The method applied offers possibilities for adequate description of dynamic muscular work which in the case of plantar flexion in trained man declines as a negative exponential function of angular motion velocity. The decline is parallel to that of maximum torques. The summed triceps surae iEMG was inversely proportional to the velocity and direct proportional to time suggesting that structural rather than neural factors determine the relationships between velocity of angular motion and maximum torque/total work of single Mmaneuvers. Moreover, the fact that maximum mean power as well as maximum electrical efficiency were reached at the functional velocity of toe-off during gait suggests an influence of pragmatic demands on plantar flexion mechanical output.
Hewett, T E; Lynch, T R; Myer, G D; Ford, K R; Gwin, R C; Heidt, R S
2014-01-01
Objective A multifactorial combination of predictors may increase anterior cruciate ligament (ACL) injury risk in athletes. The objective of this twin study was to examine these risk factors to identify commonalities in risk factors that predisposed female fraternal twins to ACL injury. Methods Female twins in high-risk sports were prospectively measured prior to an injury for neuromuscular control using three-dimensional motion analysis during landing, hamstrings and quadriceps muscular strength on a dynamometer and joint laxity using a modified Beighton–Horan index and a Compu-KT arthrometer. Intraoperative measures of femoral intercondylar notch width were recorded during ACL reconstruction. Results Abduction angles were increased at one knee in both of the twin sister athletes relative to uninjured controls at initial contact and at maximum displacement during landing. The twin female athletes that went on to ACL injury also demonstrated decreased peak knee flexion motion at both knees than uninjured females during landing. The twin athletes also had increased joint laxity and decreased hamstrings to quadriceps (H/Q) torque ratios compared to controls. Femoral intercondylar notch widths were also below the control mean in the twin siblings. Conclusions Prescreened mature female twins that subsequently experienced ACL injury demonstrated multiple potential risk factors including: increased knee abduction angles, decreased knee flexion angles, increased general joint laxity, decreased H/Q ratios and femoral intercondylar notch width. PMID:19158132
Squat exercise to estimate knee megaprosthesis rehabilitation: a pilot study
Lovecchio, Nicola; Zago, Matteo; Sciumè, Luciana; Lopresti, Maurizio; Sforza, Chiarella
2015-01-01
[Purpose] This study evaluated a specific rehabilitation protocol using a half squat after total knee reconstruction with distal femur megaprosthesis and tibial allograft-prosthesis composite. [Subject and Methods] Squat execution was recorded by a three-dimensional system before and after a specific rehabilitation program on a 28-year-old patient. Squat duration, body center of mass trajectory, and vertical range of motion were determined. Step width and joint angles and symmetry (hip flexion, extension, and rotation, knee flexion, and ankle dorsal and plantar flexion) were estimated. Knee and hip joint symmetry was computed using a bilateral cyclogram technique. [Results] After rehabilitation, the squat duration was longer (75%), step width was similar, and vertical displacement was higher. Hip flexion increased by over 20%, and ankle dorsiflexion diminished by 14%. The knee had the highest symmetry gain (4.1–3.4%). Angle-angle plot subtended areas decreased from 108° to 40°2 (hip) and from 204° to 85°2 (knee), showing improvement in movement symmetry. [Conclusion] We concluded that the squat is an effective multifactorial exercise to estimate rehabilitation outcomes after megaprosthesis, also considering that compressive and shear forces are minimal up to 60–70° of knee flexion. PMID:26311992
Sánchez-Zuriaga, Daniel; López-Pascual, Juan; Garrido-Jaén, David; García-Mas, Maria Amparo
2015-02-01
The purpose of this study was to determine the patterns of lumbopelvic motion and erector spinae (ES) activity during trunk flexion-extension movements and to compare these patterns between patients with recurrent low back pain (LBP) in their pain-free periods and matched asymptomatic subjects. Thirty subjects participated (15 patients with disc herniation and recurrent LBP in their pain-free periods and 15 asymptomatic control subjects). A 3-dimensional videophotogrammetric system and surface electromyography (EMG) were used to record the angular displacements of the lumbar spine and hip in the sagittal plane and the EMG activity of the ES during standardized trunk flexion-extension cycles. Variables were maximum ranges of spine and hip flexion; percentages of maximum lumbar and hip flexion at the start and end of ES relaxation; average percentages of EMG activity during flexion, relaxation, and extension; and flexion-extension ratio of myoelectrical activity. Recurrent LBP patients during their pain-free period showed significantly greater ES activation both in flexion and extension, with a higher flexion-extension ratio than controls. Maximum ranges of lumbar and hip flexion showed no differences between controls and patients, although patients spent less time with their lumbar spine maximally flexed. This study showed that reduced maximum ranges of motion and absence of ES flexion-relaxation phenomenon were not useful to identify LBP patients in the absence of acute pain. However, these patients showed subtle alterations of their lumbopelvic motion and ES activity patterns, which may have important clinical implications. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.
Beutler, Anthony I.; Cooper, Leslie W.; Kirkendall, Don T.; Garrett, William E.
2002-01-01
Objective: Many knee rehabilitation studies have examined open and closed kinetic chain exercises. However, most studies focus on 2-legged, closed chain exercise. The purpose of our study was to characterize 1-legged, closed chain exercise in young, healthy subjects. Subjects: Eighteen normal subjects (11 men, 7 women; age, 24.6 ± 1.6 years) performed unsupported, 1-legged squats and step-ups to approximately tibial height. Measurements: Knee angle data and surface electromyographic activity from the thigh muscles were recorded. Results: The maximum angle of knee flexion was 111 ± 23° for squats and 101 ± 16° for step-ups. The peak quadriceps activation was 201 ± 66% maximum voluntary isometric contraction, occurring at an angle of 96 ± 16° for squats. Peak quadriceps activation was 207 ± 50% maximum voluntary isometric contraction and occurred at 83 ± 12° for step-ups. Conclusions: The high and sustained levels of quadriceps activation indicate that 1-legged squats and step-ups would be effective in muscle rehabilitation. As functional, closed chain activities, they may also be protective of anterior cruciate ligament grafts. Because these exercises involve no weights or training equipment, they may prove more cost effective than traditional modes of rehabilitation. PMID:12937438
Effect of Human Movement on Galvanic Intra-Body Communication during Single Gait Cycle
NASA Astrophysics Data System (ADS)
Ibrahim, I. W.; Razak, A. H. A.; Ahmad, A.; Salleh, M. K. M.
2015-11-01
Intra-body communication (IBC) is a communication system that uses human body as a signal transmission medium. From previous research, two coupling methods of IBC were concluded which are capacitive coupling and galvanic coupling. This paper investigates the effect of human movement on IBC using the galvanic coupling method. Because the human movement is control by the limb joint, the knee flexion angle during gait cycle was used to examine the influence of human movement on galvanic coupling IBC. The gait cycle is a cycle of people walking that start from one foot touch the ground till that foot touch the ground again. Frequency range from 300 kHz to 200MHz was swept in order to investigate the signal transmission loss and the result was focused on operating frequency 70MHz to 90MHz. Results show that the transmission loss varies when the knee flexion angle increased. The highest loss of signal at frequency range between 70MHz to 90 MHz was 69dB when the knee flexion angle is 50° and the minimum loss was 51dB during the flexion angle is 5°.
The influence of muscles on knee flexion during the swing phase of gait.
Piazza, S J; Delp, S L
1996-06-01
Although the movement of the leg during swing phase is often compared to the unforced motion of a compound pendulum, the muscles of the leg are active during swing and presumably influence its motion. To examine the roles of muscles in determining swing phase knee flexion, we developed a muscle-actuated forward dynamic simulation of the swing phase of normal gait. Joint angles and angular velocities at toe-off were derived from experimental measurements, as were pelvis motions and muscle excitations. Joint angles and joint moments resulting from the simulation corresponded to experimental measurements made during normal gait. Muscular joint moments and initial joint angular velocities were altered to determine the effects of each upon peak knee flexion in swing phase. As expected, the simulation demonstrated that either increasing knee extension moment or decreasing toe-off knee flexion velocity decreased peak knee flexion. Decreasing hip flexion moment or increasing toe-off hip flexion velocity also caused substantial decreases in peak knee flexion. The rectus femoris muscle played an important role in regulating knee flexion; removal of the rectus femoris actuator from the model resulted in hyperflexion of the knee, whereas an increase in the excitation input to the rectus femoris actuator reduced knee flexion. These findings confirm that reduced knee flexion during the swing phase (stiff-knee gait) may be caused by overactivity of the rectus femoris. The simulations also suggest that weakened hip flexors and stance phase factors that determine the angular velocities of the knee and hip at toe-off may be responsible for decreased knee flexion during swing phase.
Aubin, Carl-Eric; Cammarata, Marco; Wang, Xiaoyu; Mac-Thiong, Jean-Marc
2015-05-01
Biomechanical analysis of proximal junctional kyphosis (PJK) through numerical simulations. Assessment of the effect of sagittal alignment, the upper instrumented vertebral level (UIV), and 4 other surgical variables on biomechanical indices related to the PJK risks. Despite retrospective clinical studies, biomechanical analysis of individual parameters associated with PJK is lacking to support instrumentation strategies to reduce the PJK risks. Instrumentations of 6 adult scoliosis cases with different operative strategies were simulated (1,152 simulations). Proximal junctional (PJ) angle and flexion loads were evaluated against the sagittal alignment and the proximal instrumentation level. Instrumenting 1 more proximal vertebra allowed the PJ angle, proximal moment, and force to be reduced by 18%, 25%, and 16%, respectively. Shifting sagittal alignment by 20 mm posteriorly increased the PJ angle and proximal moment by 16% and 22%, and increased the equivalent posterior extensor force by 37%. Bilateral complete facetectomy, posterior ligaments resection, and the combination of the 2 resulted in an increase of the PJ angle (by 10%, 28%, and 53%, respectively), flexion forces (by 4%, 12%, and 22%, respectively), and proximal moments (by 16%, 44%, and 83%, respectively). Transverse process hooks at UIV compared with pedicle screws allowed 26% lower PJ angle and flexion loads. The use of proximal transition rods with proximal diameter reduced from 5.5 to 4 mm slightly reduced PJ angle, flexion force, and moment (less than 8%). The increase in sagittal rod curvature from 10° to 40° increased the PJ angle (from 6% to 19%), flexion force (from 3% to 10%), and moment (from 9% to 27%). Simulated posteriorly shifted sagittal alignment was associated with higher PJK risks, whereas extending instrumentation proximally allowed a lower mechanical risk of PJK. Preserving PJ intervertebral elements and using a more flexible anchorage at UIV help reduce the biomechanical risks of PJK. Copyright © 2015 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.
Ishikawa, Yoshinori; Miyakoshi, Naohisa; Hongo, Michio; Kasukawa, Yuji; Kudo, Daisuke; Shimada, Yoichi
2017-03-01
Spinal deformities can affect quality of life (QOL) and risk of falling, but no studies have explored the relationships of spinal mobility and sagittal alignment of spine and the lower extremities simultaneously. Purpose of this study is to clarify the relationship of those postural parameters to QOL and risk of falling. The study evaluated 110 subjects (41 men, 69 women; mean age, 73 years). Upright and flexion and extension angles for thoracic kyphosis, lumbar lordosis, and spinal inclination were evaluated with SpinalMouse ® . Total-body inclination and hip and knee flexion angles in upright position were measured from lateral photographs. Subjects were divided into Fallers (n=23, 21%) and Non-fallers (n=87, 79%) based on past history of falls. QOL was assessed using the Short Form 36 Health Survey (SF-36 ® ). Age, total-body inclination, spinal inclination upright and in extension, thoracic kyphosis in flexion, lumbar lordosis upright and in extension, and knee flexion correlated significantly with the SF-36. Multiple regression analysis revealed total-body inclination and knee flexion to have the most significant relationships with the SF-36. SF-36, total-body inclination, spinal inclination in extension, thoracic kyphosis in flexion, lumbar lordosis upright and in extension, and hip and knee flexion angles differed significantly between Fallers and Non-fallers (P<0.05 for all). Multivariate logistic regression analyses revealed lumbar lordosis in extension to be a significant predictor of falling (P=0.038). Forward-stooped posture and knee-flexion deformity could be important indicator of lower QOL. Moreover, limited extension in the lumbar spine could be a useful screening examination for fall prevention in the elderly. Copyright © 2017 Elsevier B.V. All rights reserved.
Task-specific fall prevention training is effective for warfighters with transtibial amputations.
Kaufman, Kenton R; Wyatt, Marilynn P; Sessoms, Pinata H; Grabiner, Mark D
2014-10-01
Key factors limiting patients with lower extremity amputations to achieve maximal functional capabilities are falls and fear of falling. A task-specific fall prevention training program has successfully reduced prospectively recorded trip-related falls that occur in the community by the elderly. However, this program has not been tested in amputees. In a cohort of unilateral transtibial amputees, we aimed to assess effectiveness of a falls prevention training program by (1) quantifying improvements in trunk control; (2) measuring responses to a standardized perturbation; and (3) demonstrating retention at 3 and 6 months after training. Second, we collected patient-reported outcomes for balance confidence and falls control. Fourteen male military service members (26 ± 3 years) with unilateral transtibial amputations and who had been walking without an assistive device for a median of 10 months (range, 2-106 months) were recruited to participate in this prospective cohort study. The training program used a microprocessor-controlled treadmill designed to deliver task-specific postural perturbations that simulated a trip. The training consisted of six 30-minute sessions delivered over a 2-week period, during which task difficulty, including perturbation magnitude, increased as the patient's ability progressed. Training effectiveness was assessed using a perturbation test in an immersive virtual environment. The key outcome variables were peak trunk flexion and velocity, because trunk kinematics at the recovery step have been shown to be a determinant of fall likelihood. The patient-reported outcomes were also collected using questionnaires. The effectiveness of the rehabilitation program was also assessed by collecting data before perturbation training and comparing the key outcome parameters with those measured immediately after perturbation training (0 months) as well as both 3 and 6 months posttraining. Mean trunk flexion angle and velocity significantly improved after participating in the training program. The prosthetic limb trunk flexion angle improved from pretraining (42°; 95% confidence interval [CI], 38°-47°) to after training (31°; 95% CI, 25°-37°; p < 0.001). Likewise, the trunk flexion velocity improved from pretraining (187°/sec; 95% CI, 166°-209°) to after training (143°/sec; 95% CI, 119°-167°; p < 0.004). The results display a significant side-to-side difference for peak trunk flexion angle (p = 0.01) with perturbations of the prosthetic limb resulting in higher peak angles. Prosthetic limb trips also exhibited significantly greater peak trunk flexion velocity compared with trips of the prosthetic limb (p = 0.005). These changes were maintained up to 6 months after the training. The peak trunk flexion angle of the subjects when the prosthetic limb was perturbed had a mean of 31° (95% CI, 25°-37°) at 0 month, 32° (95% CI, 28°-37°) at 3 months, and 30° (95% CI, 25°-34°) at 6 months. Likewise, the peak trunk flexion velocity for the prosthetic limb was a mean of 143°/sec (95% CI, 118°-167°) at 0 months, 143°/sec (95% CI, 126°-159°) at 3 months, and 132° (95% CI, 115°-149°) at 6 months. The peak trunk flexion angle when the nonprosthetic limb was perturbed had a mean of 22° (95% CI, 18°-24°) at 0 months, a mean of 26° (95% CI, 20°-32°) at 3 months, and a mean of 23° (95% CI, 19°-28°) at 6 months. The peak trunk flexion velocity for the nonprosthetic limb had a mean of 85°/sec (95% CI, 71°-98°) at 0 months, a mean of 96° (95% CI, 68°-124°) at 3 months, and 87°/sec (95% CI, 68°-105°) at 6 months. There were no significant changes in the peak trunk flexion angle (p = 0.16) or peak trunk flexion velocity (p = 0.35) over time after the training ended. The skill retention was present when either the prosthetic or nonprosthetic limb was perturbed. There were side-to-side differences in the trunk flexion angle (p = 0.038) and trunk flexion velocity (p = 0.004). Perturbations of the prosthetic side resulted in larger trunk flexion and higher trunk flexion velocities. Subjects prospectively reported decreased stumbles, semicontrolled falls, and uncontrolled falls. These results indicate that task-specific fall prevention training is an effective rehabilitation method to reduce falls in persons with lower extremity transtibial amputations.
Malfait, Bart; Dingenen, Bart; Smeets, Annemie; Staes, Filip; Pataky, Todd; Robinson, Mark A.; Vanrenterghem, Jos; Verschueren, Sabine
2016-01-01
Purpose The purpose was to assess if variation in sagittal plane landing kinematics is associated with variation in neuromuscular activation patterns of the quadriceps-hamstrings muscle groups during drop vertical jumps (DVJ). Methods Fifty female athletes performed three DVJ. The relationship between peak knee and hip flexion angles and the amplitude of four EMG vectors was investigated with trajectory-level canonical correlation analyses over the entire time period of the landing phase. EMG vectors consisted of the {vastus medialis(VM),vastus lateralis(VL)}, {vastus medialis(VM),hamstring medialis(HM)}, {hamstring medialis(HM),hamstring lateralis(HL)} and the {vastus lateralis(VL),hamstring lateralis(HL)}. To estimate the contribution of each individual muscle, linear regressions were also conducted using one-dimensional statistical parametric mapping. Results The peak knee flexion angle was significantly positively associated with the amplitudes of the {VM,HM} and {HM,HL} during the preparatory and initial contact phase and with the {VL,HL} vector during the peak loading phase (p<0.05). Small peak knee flexion angles were significantly associated with higher HM amplitudes during the preparatory and initial contact phase (p<0.001). The amplitudes of the {VM,VL} and {VL,HL} were significantly positively associated with the peak hip flexion angle during the peak loading phase (p<0.05). Small peak hip flexion angles were significantly associated with higher VL amplitudes during the peak loading phase (p = 0.001). Higher external knee abduction and flexion moments were found in participants landing with less flexed knee and hip joints (p<0.001). Conclusion This study demonstrated clear associations between neuromuscular activation patterns and landing kinematics in the sagittal plane during specific parts of the landing. These findings have indicated that an erect landing pattern, characterized by less hip and knee flexion, was significantly associated with an increased medial and posterior neuromuscular activation (dominant hamstrings medialis activity) during the preparatory and initial contact phase and an increased lateral neuromuscular activation (dominant vastus lateralis activity) during the peak loading phase. PMID:27101130
Oñate, James A; Guskiewicz, Kevin M; Marshall, Stephen W; Giuliani, Carol; Yu, Bing; Garrett, William E
2005-06-01
Anterior cruciate ligament injury prevention programs have used videotapes of jump-landing technique as a key instructional component to improve landing performance. All videotape feedback model groups will increase knee flexion angles at initial contact and overall knee flexion motion and decrease peak vertical ground reaction forces and peak proximal anterior tibial shear forces to a greater extent than will a nonfeedback group. The secondary hypothesis is that the videotape feedback using the combination of the expert and self models will create the greatest change in each variable. Controlled laboratory study. Knee kinematics and kinetics of college-aged recreational athletes randomly placed in 3 different videotape feedback model groups (expert only, self only, combination of expert and self) and a nonfeedback group were collected while participants performed a basketball jump-landing task on 3 testing occasions. All feedback groups significantly increased knee angular displacement flexion angles [F(6,70) = 8.03, P = .001] and decreased peak vertical ground reaction forces [F(6,78) = 2.68, P = .021] during performance and retention tests. The self and combination groups significantly increased knee angular displacement flexion angles more than the control group did; the expert model group did not change significantly more than the control group did. All feedback groups and the nonfeedback group significantly reduced peak vertical forces across performance and retention tests. There were no statistically significant changes in knee flexion angle at initial ground contact (P = .111) and peak proximal anterior tibial shear forces (P = .509) for both testing sessions for each group. The use of self or combination videotape feedback is most useful for increasing knee angular displacement flexion angles and reducing peak vertical forces during landing. The use of self or combination modeling is more effective than is expert-only modeling for the implementation of instructional programs aimed at reducing the risk of jump-landing anterior cruciate ligament injuries.
Hino, Kazunori; Oonishi, Yoshio; Kutsuna, Tatsuhiko; Watamori, Kunihiko; Iseki, Yasutake; Kiyomatsu, Hiroshi; Watanabe, Seiji; Miura, Hiromasa
2016-08-01
Restoration of normal knee kinematics is key to improving patient satisfaction and functional outcomes after total knee arthroplasty (TKA). However, the effect of preoperative varus-valgus kinematics due to knee osteoarthritis on the postoperative kinematics is unclear. The function of the knee ligament contributes to both knee stability and kinematics. The aim of this study was to evaluate changes in varus-valgus kinematics before and after TKA using a navigation system, in addition to comparing the pre- and postoperative changes in kinematic patterns between cruciate-retaining (CR)- and posterior-stabilized (PS)-TKAs. Forty knees treated with TKA were evaluated (CR-TKA 20; PS-TKA 20). Manual mild passive knee flexion was applied while moving the leg from full extension to flexion. The varus-valgus angle was automatically measured by a navigation system at every 10° of the flexion angle, and the kinematics were evaluated. Kinematic patterns throughout flexion can be classified into five types. The pre- and postoperative kinematic patterns were similar in 60% of patients who underwent CR-TKA, whereas they were similar in only 25% of those who underwent PS-TKA. The mean change in the size of the varus-valgus angle throughout flexion did not differ between CR-TKA and PS-TKA. However, the distribution of changes in the size of the varus-valgus angle differed between CR-TKA and PS-TKA. We obtained the following results: 1) some patterns of varus-valgus kinematics are noted under unloading conditions despite recovery of neutral alignment in extension and 2) the preoperative varus-valgus kinematic pattern persisted more strongly after CR-TKA than after PS-TKA. Copyright © 2015 Elsevier B.V. All rights reserved.
Touch-screen tablet user configurations and case-supported tilt affect head and neck flexion angles.
Young, Justin G; Trudeau, Matthieu; Odell, Dan; Marinelli, Kim; Dennerlein, Jack T
2012-01-01
The aim of this study was to determine how head and neck postures vary when using two media tablet (slate) computers in four common user configurations. Fifteen experienced media tablet users completed a set of simulated tasks with two media tablets in four typical user configurations. The four configurations were: on the lap and held with the user's hands, on the lap and in a case, on a table and in a case, and on a table and in a case set at a high angle for watching movies. An infra-red LED marker based motion analysis system measured head/neck postures. Head and neck flexion significantly varied across the four configurations and across the two tablets tested. Head and neck flexion angles during tablet use were greater, in general, than angles previously reported for desktop and notebook computing. Postural differences between tablets were driven by case designs, which provided significantly different tilt angles, while postural differences between configurations were driven by gaze and viewing angles. Head and neck posture during tablet computing can be improved by placing the tablet higher to avoid low gaze angles (i.e. on a table rather than on the lap) and through the use of a case that provides optimal viewing angles.
Hino, Kazunori; Kutsuna, Tatsuhiko; Watamori, Kunihiko; Kiyomatsu, Hiroshi; Ishimaru, Yasumitsu; Takeba, Jun; Watanabe, Seiji; Shiraishi, Yoshitaka; Miura, Hiromasa
2017-10-01
Midflexion stability can potentially improve the outcome of total knee arthroplasty (TKA). The purpose of this study was to evaluate the correlation between varus-valgus stability at 0° of extension and 90° of flexion and that at the midflexion range in posterior-stabilized (PS)-TKA. Forty-three knees that underwent PS-TKA were evaluated. Manual mild passive varus-valgus stress was applied to the knees, and the postoperative maximum varus-valgus stability was measured every 10° throughout range of motion, using a navigation system. Correlations between the stability at 0°, 90° of flexion, and that at each midflexion angle were evaluated using Spearman's correlation coefficients. The stability of 0° modestly correlated with that of 10°-20°, but it did not significantly correlate with that of 30°-80°. However, the stability of 90° strongly correlated with that of 60°-80°, modestly correlated with that of 40°-50°, weakly correlated with that of 20°-30°, and did not correlate with that of 10°. The present study confirmed the importance of acquiring stability at 90° flexion to achieve midflexion stability in PS-TKA. However, initial flexion stability did not strongly correlate with the stability at either 0° or 90°. Our findings can provide useful information for understanding varus-valgus stability throughout the range of motion in PS-TKA. Attention to soft tissue balancing is necessary to stabilize a knee at the initial flexion range in PS-TKA.
Stephensen, D; Drechsler, W; Winter, M; Scott, O
2009-03-01
Quality of life for children with haemophilia has improved since the introduction of prophylaxis. The frequency of joint haemorrhages has reduced, but the consequences of reduced bleeding on the biomechanical parameters of walking are not well understood. This study explored the differences in sagittal plane biomechanics of walking between a control group (Group 1) of normal age-matched children and children with haemophilia (Group 2) with a target ankle joint. A motion capture system and two force platforms were used to collect sagittal plane kinematic, kinetic and temporal-spatial data during walking of 14 age-matched normal children and 14 children with haemophilia aged 7-13 years. Group differences in maximum and minimum flexion/extension angles and moments of the hip, knee and ankle joints, ground reaction forces and temporal-spatial gait cycle parameters were analysed using one-way anova. Significant changes (P < 0.05) in kinematic and kinetic parameters but not temporal-spatial parameters were found in children with haemophilia; greater flexion angles and external moments of force at the knee, greater ankle plantarflexion external moments and lower hip flexion external moments. These results suggest that early biomechanical changes are present in young haemophilic children with a history of a target ankle joint and imply that lower limb joint function is more impaired than current clinical evaluations indicate. Protocols and quantitative data on the biomechanical gait pattern of children with haemophilia reported in this study provide a baseline to evaluate lower limb joint function and clinical progression.
Cuéllar, Vanessa G; Martinez, Danny; Immerman, Igor; Oh, Cheongeun; Walker, Peter S; Egol, Kenneth A
2015-07-01
Although the posteromedial fragment in tibial plateau fractures is often considered unstable, biomechanical evidence supporting this view is lacking. We aimed to evaluate the stability of the fragment in a cadaver model. Our hypothesis was that under the expected small axial force during rehabilitation and the combined effects of this force with shear force, internal rotation torque, and varus moment, the most common posteromedial tibial fragment morphology could maintain stability in early flexion. Axial compression force alone or combined with posterior shear, internal rotation torque, or varus moment was applied to the femurs of 5 fresh cadaveric knees. A Tekscan pressure mapping system was used to measure pressure and contact area between the femoral condyles, meniscus, and tibial plateau. A Microscribe 3D digitizer was used to define the 3-dimensional positions of the femur and tibia. A 10-mm and then a 20-mm osteotomy was created with a saw at an angle of 30 degrees in the axial plane with respect to the tangent of the posterior tibial plateau and 75 degrees in the sagittal plane, representing a typical posteromedial fracture fragment. At each flexion angle (15, 30, 60, 90, and 120 degrees) and loading condition (axial compression only, compression with shear force, torque, and varus moment), distal displacement of the medial femoral condyle and the tibial fracture fragments was determined. For the 10-mm fragment, medial femoral condyle displacement was little affected up to approximately 30-degree flexion, after which it increased. For the 20-mm fragment, there was progressive medial femoral condyle displacement with increasing flexion from baseline. However, for the 10- and 20-mm fragments themselves, displacements were noted at every flexion angle, starting at 1.7 mm inferior displacement with 15 degrees of flexion and internal rotation torque and up to 10.2 mm displacement with 90 degrees of flexion and varus bending moment. In this cadaveric model of a posteromedial tibial plateau fracture, both fracture fragments studied displaced with knee flexion, even at low flexion angles. Although such fragments may initially seem nondisplaced after injury, posteromedial fragments similar to these tested are likely to displace during knee range of motion exercises in non-weight-bearing conditions.
The biomechanical effect of increased valgus on total knee arthroplasty: a cadaveric study.
Bryant, Brandon J; Tilan, Justin U; McGarry, Michelle H; Takenaka, Nobuyuki; Kim, William C; Lee, Thay Q
2014-04-01
The effects of valgus load on cadaveric knees following total knee arthroplasty (TKA) were investigated using a custom testing system. TKAs were performed on 8 cadaveric knees and tested at 0°, 30°, and 60° knee flexion in both neutral and 5° valgus. Fuji pressure sensitive film was used to quantify contact areas and pressures and MCL strain was determined using a Microscribe digitizing system. Lateral tibiofemoral pressures increased (P < 0.05) at all knee flexion angles with valgus loading. Patellofemoral contact characteristics did not change significantly (P > 0.05). Significant increases in strain were observed along the anterior and posterior border of the MCL at all knee flexion angles. These findings suggest that valgus loading increases TKA joint contact pressures and MCL strain with increasing knee flexion which may increase implant instability. © 2014.
Mortazavi, S M J; Heidari, P; Esfandiari, H; Motamedi, M
2008-01-01
Flexion deformity of the haemophilic knee is a considerable cause of disability and may need to be managed surgically in severe cases. We have used a trapezoid supracondylar femoral extension osteotomy to correct severe knee flexion deformity. Nine severe haemophilic patients with contractures >30 degrees that were unresponsive to conservative measures underwent 11 trapezoid osteotomies. The angle of deformity was measured using anteroposterior and lateral knee X-ray films at maximum extension. Factor levels of 80-100% were achieved before the operation. A trapezoid osteotomy of the distal femur bone was performed using a lateral approach. The frontal plane angular deformity (if any) was corrected at the same time. The osteotomy site was fixed using an Arbeitsgemeinschaft für Osteo synthesefragen (AO) condylar blade plate. Following surgery, the knee was supported by a plaster splint at 20 degrees of flexion. Physiotherapy was started on third postoperative day and continued three times a week. There was no serious complication. The deformities were corrected in all of the patients and the mean range of motion increased form 68.6 degrees to 98.1 degrees . Bleeding episodes decreased in all four knees which had a bleeding score of 3 before surgery. Using the Orthopaedic Advisory Committee of the World Federation of Haemophilia scores, nine good and two fair results were obtained. All patients regained the ability to walk for both short and long distance without any aid, climb the stairs, bath, and use public transportation. Trapezoid supracondylar femoral extension osteotomy should be considered in the surgical management of severe haemophilic flexion deformity of the knee joint.
Method for measuring tri-axial lumbar motion angles using wearable sheet stretch sensors
Nakamoto, Hiroyuki; Yamaji, Tokiya; Ootaka, Hideo; Bessho, Yusuke; Nakamura, Ryo; Ono, Rei
2017-01-01
Background Body movements, such as trunk flexion and rotation, are risk factors for low back pain in occupational settings, especially in healthcare workers. Wearable motion capture systems are potentially useful to monitor lower back movement in healthcare workers to help avoid the risk factors. In this study, we propose a novel system using sheet stretch sensors and investigate the system validity for estimating lower back movement. Methods Six volunteers (female:male = 1:1, mean age: 24.8 ± 4.0 years, height 166.7 ± 5.6 cm, weight 56.3 ± 7.6 kg) participated in test protocols that involved executing seven types of movements. The movements were three uniaxial trunk movements (i.e., trunk flexion-extension, trunk side-bending, and trunk rotation) and four multiaxial trunk movements (i.e., flexion + rotation, flexion + side-bending, side-bending + rotation, and moving around the cranial–caudal axis). Each trial lasted for approximately 30 s. Four stretch sensors were attached to each participant’s lower back. The lumbar motion angles were estimated using simple linear regression analysis based on the stretch sensor outputs and compared with those obtained by the optical motion capture system. Results The estimated lumbar motion angles showed a good correlation with the actual angles, with correlation values of r = 0.68 (SD = 0.35), r = 0.60 (SD = 0.19), and r = 0.72 (SD = 0.18) for the flexion-extension, side bending, and rotation movements, respectively (all P < 0.05). The estimation errors in all three directions were less than 3°. Conclusion The stretch sensors mounted on the back provided reasonable estimates of the lumbar motion angles. The novel motion capture system provided three directional angles without capture space limits. The wearable system possessed great potential to monitor the lower back movement in healthcare workers and helping prevent low back pain. PMID:29020053
Analysis of Balance Ability Dependent on the Angle of the Knee Joint in Females in Their 20s
Yoon, Se-Won; Lee, Jeong-Woo; Cho, Woon-Su; Kim, An-Na; Lee, Kyung-Hee
2013-01-01
The aim of this study was to investigate how balance ability according to angle of the knee joint changes in young female adults wearing a knee orthosis. [Methods] This study was conducted with 11 healthy female adults. The subjects used a knee brace that could be set to angles of 0°, 15°, and 30° of knee flexion. The ability to balance was evaluated by balance assessment. A total of four postures were used for measurements: a forward-facing posture with the eyes open on a stable surface (NO), a forward-facing posture with the eyes closed on a stable surface (NC), a forward-facing posture with the eyes open on an unstable surface (PO), and a forward-facing posture with the eyes closed on an unstable surface (PC). [Results] Regarding the weight distribution index and stability index on a stable surface, there was no interaction according to whether there was visual deprivation or not or according to knee flexion angle. Furthermore, the stability index on an unstable surface showed no interaction according to whether there was visual deprivation or not or according to knee flexion angle. But the WDI on a stable surface showed no interaction according to whether there was visual deprivation or not or according to knee flexion angle. [Conclusion] There were significant differences in the knee extension range of motion of normal elderly people and knee osteoarthritis, and the quadriceps femoris played an important role in knee function in individuals with knee osteoarthritis. PMID:24259902
Gao, Shu-Guang; Zhang, Can; Zhao, Rui-Bo; Liao, Zhan; Li, Yu-Sheng; Yu, Fang; Zeng, Chao; Luo, Wei; Li, Kang-Hua; Lei, Guang-Hua
2013-09-01
The relationship between medial meniscus tear and posterior cruciate ligament (PCL) injury has not been exactly explained. We studied to investigate the biomechanical effect of partial and complete PCL transection on different parts of medial meniscus at different flexion angles under static loading conditions. TWELVE FRESH HUMAN CADAVERIC KNEE SPECIMENS WERE DIVIDED INTO FOUR GROUPS: PCL intact (PCL-I), anterolateral bundle transection (ALB-T), posteromedial bundle transection (PMB-T) and PCL complete transection (PCL-T) group. Strain on the anterior horn, body part and posterior horn of medial meniscus were measured under different axial compressive tibial loads (200-800 N) at 0°, 30°, 60° and 90° knee flexion in each groups respectively. Compared with the PCL-I group, the PCL-T group had a higher strain on whole medial meniscus at 30°, 60° and 90° flexion in all loading conditions and at 0° flexion with 400, 600 and 800 N loads. In ALB-T group, strain on whole meniscus increased at 30°, 60° and 90° flexion under all loading conditions and at 0° flexion with 800 N only. PMB-T exihibited higher strain at 0° flexion with 400 N, 600 N and 800 N, while at 30° and 60° flexion with 800 N and at 90° flexion under all loading conditions. Partial PCL transection triggers strain concentration on medial meniscus and the effect is more pronounced with higher loading conditions at higher flexion angles.
Lee, Sang-Ho; Lee, Ho-Yeon; Baek, Oon Ki; Bae, Jun Seok; Yoo, Seung-Hwa; Lee, June-Ho
2015-03-15
Retrospective clinical study. To evaluate the effect of the limitation of flexion rotation clinically and radiologically after interspinous soft stabilization using a tension band system in grade 1 degenerative spondylolisthesis. Although several studies have been published on the clinical effects of limiting rotatory motion using tension band systems, which mainly targets the limitation of flexion rather than that of extension, they were confined to the category of pedicle screw-based systems, revealing inconsistent long-term outcomes. Sixty-one patients with a mean age of 60.6 years (range, 28-76 yr) who underwent interspinous soft stabilization after decompression for grade 1 degenerative spondylolisthesis with stenosis between 2002 and 2004 were analyzed. At follow-up, the patients were divided into 2 groups on the basis of their achievement or failure to achieve flexion limitation. The clinical and radiological findings were analyzed. A multiple linear regression analysis was performed to determine the prognostic factors for surgical outcomes. At a mean follow-up duration of 72.5 months (range, 61-82 mo), 51 patients were classified into the flexion-limited group and 10 into the flexion-unlimited group. Statistically significant improvements were noted only in the flexion-limited group in all clinical scores. In the flexion-unlimited group, there were significant deteriorations in flexion angle (P = 0.009), axial thickness of the ligamentum flavum (P = 0.013), and the foraminal cross-sectional area (P = 0.011), resulting in significant intergroup differences. The preoperative extension angle was identified as the most influential variable for the flexion limitation and the clinical outcomes. The effects of the limitation of flexion rotation achieved through interspinous soft stabilization using a tension band system after decompression were related to the prevention of late recurrent stenosis and resultant radicular pain caused by flexion instability. The extension potential at the index level was recognized as a major prognostic factor that can predict the flexion limitation and the clinical results. 4.
Comparative assessment of bone pose estimation using Point Cluster Technique and OpenSim.
Lathrop, Rebecca L; Chaudhari, Ajit M W; Siston, Robert A
2011-11-01
Estimating the position of the bones from optical motion capture data is a challenge associated with human movement analysis. Bone pose estimation techniques such as the Point Cluster Technique (PCT) and simulations of movement through software packages such as OpenSim are used to minimize soft tissue artifact and estimate skeletal position; however, using different methods for analysis may produce differing kinematic results which could lead to differences in clinical interpretation such as a misclassification of normal or pathological gait. This study evaluated the differences present in knee joint kinematics as a result of calculating joint angles using various techniques. We calculated knee joint kinematics from experimental gait data using the standard PCT, the least squares approach in OpenSim applied to experimental marker data, and the least squares approach in OpenSim applied to the results of the PCT algorithm. Maximum and resultant RMS differences in knee angles were calculated between all techniques. We observed differences in flexion/extension, varus/valgus, and internal/external rotation angles between all approaches. The largest differences were between the PCT results and all results calculated using OpenSim. The RMS differences averaged nearly 5° for flexion/extension angles with maximum differences exceeding 15°. Average RMS differences were relatively small (< 1.08°) between results calculated within OpenSim, suggesting that the choice of marker weighting is not critical to the results of the least squares inverse kinematics calculations. The largest difference between techniques appeared to be a constant offset between the PCT and all OpenSim results, which may be due to differences in the definition of anatomical reference frames, scaling of musculoskeletal models, and/or placement of virtual markers within OpenSim. Different methods for data analysis can produce largely different kinematic results, which could lead to the misclassification of normal or pathological gait. Improved techniques to allow non-uniform scaling of generic models to more accurately reflect subject-specific bone geometries and anatomical reference frames may reduce differences between bone pose estimation techniques and allow for comparison across gait analysis platforms.
Biscarini, Andrea; Botti, Fabio M; Pettorossi, Vito E
2013-02-01
We developed a biomechanical model to determine the joint torques and loadings during squatting with a backward/forward-inclined Smith machine. The Smith squat allows a large variety of body positioning (trunk tilt, foot placement, combinations of joint angles) and easy control of weight distribution between forefoot and heel. These distinctive aspects of the exercise can be managed concurrently with the equipment inclination selected to unload specific joint structures while activating specific muscle groups. A backward (forward) equipment inclination decreases (increases) knee torque, and compressive tibiofemoral and patellofemoral forces, while enhances (depresses) hip and lumbosacral torques. For small knee flexion angles, the strain-force on the posterior cruciate ligament increases (decreases) with a backward (forward) equipment inclination, whereas for large knee flexion angles, this behavior is reversed. In the 0 to 60 degree range of knee flexion angles, loads on both cruciate ligaments may be simultaneously suppressed by a 30 degree backward equipment inclination and selecting, for each value of the knee angle, specific pairs of ankle and hip angles. The anterior cruciate ligament is safely maintained unloaded by squatting with backward equipment inclination and uniform/forward foot weight distribution. The conditions for the development of anterior cruciate ligament strain forces are clearly explained.
The role of the deep medial collateral ligament in controlling rotational stability of the knee.
Cavaignac, Etienne; Carpentier, Karel; Pailhé, Regis; Luyckx, Thomas; Bellemans, Johan
2015-10-01
The tibial insertion of the deep medial collateral ligament (dMCL) is frequently sacrificed when the proximal tibial cut is performed during total knee arthroplasty. The role of the dMCL in controlling the knee's rotational stability is still controversial. The aim of this study was to quantify the rotational laxity induced by an isolated lesion of the dMCL as it occurs during tibial preparation for knee arthroplasty. An isolated resection of the deep MCL was performed in 10 fresh-frozen cadaver knees. Rotational laxity was measured during application of a standard 5.0 N.m rotational torque. Maximal tibial rotation was measured at different knee flexion angles using an image-guided navigation system (Medivision Surgetics system, Praxim, Grenoble, France) before and after dMCL resection. In all cases, internal and external tibial rotation increased after dMCL resection. Total rotational laxity increased significantly for all knee flexion angles, with an average difference of +7.8° (SD 5.7) with the knee in extension, +8.9° (SD 1.9) in 30° flexion, +7° (SD 2.9) in 60° flexion and +5.3° (SD 2.8) in 90° flexion. Sacrificing the tibial insertion of the deep MCL increases rotational laxity of the knee by 5°-9°, depending on the knee flexion angle. Based on our findings, new surgical techniques and implants that preserve the dMCL insertion such as tibial inlay components should be developed. Further clinical evaluations are necessary.
The effect of hip positioning on the projected femoral neck-shaft angle: a modeling study.
Bhashyam, Abhiram R; Rodriguez, Edward K; Appleton, Paul; Wixted, John J
2018-04-03
The femoral neck-shaft angle (NSA) is used to restore normal hip geometry during hip fracture repair. Femoral rotation is known to affect NSA measurement, but the effect of hip flexion-extension is unknown. The goals of this study were to determine and test mathematical models of the relationship between hip flexion-extension, femoral rotation and NSA. We hypothesized that hip flexion-extension and femoral rotation would result in NSA measurement error. Two mathematical models were developed to predict NSA in varying degrees of hip flexion-extension and femoral rotation. The predictions of the equations were tested in vitro using a model that varied hip flexion-extension while keeping rotation constant, and vice versa. The NSA was measured from an AP radiograph obtained with a C-arm. Attributable measurement error based on hip positioning was calculated from the models. The predictions of the model correlated well with the experimental data (correlation coefficient = 0.82 - 0.90). A wide range of patient positioning was found to result in less than 5-10 degree error in the measurement of NSA. Hip flexion-extension and femoral rotation had a synergistic effect in measurement error of the NSA. Measurement error was minimized when hip flexion-extension was within 10 degrees of neutral. This study demonstrates that hip flexion-extension and femoral rotation significantly affect the measurement of the NSA. To avoid inadvertently fixing the proximal femur in varus or valgus, the hip should be positioned within 10 degrees of neutral flexion-extension with respect to the C-arm to minimize positional measurement error. N/A, basic science study.
Joint angle affects volitional and magnetically-evoked neuromuscular performance differentially.
Minshull, C; Rees, D; Gleeson, N P
2011-08-01
This study examined the volitional and magnetically-evoked neuromuscular performance of the quadriceps femoris at functional knee joint angles adjacent to full extension. Indices of volitional and magnetically-evoked neuromuscular performance (N=15 healthy males, 23.5 ± 2.9 years, 71.5 ± 5.4 kg, 176.5 ± 5.5 cm) were obtained at 25°, 35° and 45° of knee flexion. Results showed that volitional and magnetically-evoked peak force (PF(V) and P(T)F(E), respectively) and electromechanical delay (EMD(V) and EMD(E), respectively) were enhanced by increased knee flexion. However, greater relative improvements in volitional compared to evoked indices of neuromuscular performance were observed with increasing flexion from 25° to 45° (e.g. EMD(V), EMD(E): 36% vs. 11% improvement, respectively; F([2,14])=6.8, p<0.05). There were no significant correlations between EMD(V) and EMD(E) or PF(V) and P(T)F(E), at analogous joint positions. These findings suggest that the extent of the relative differential between volitional and evoked neuromuscular performance capabilities is joint angle-specific and not correlated with performance capabilities at adjacent angles, but tends to be smaller with increased flexion. As such, effective prediction of volitional from evoked performance capabilities at both analogous and adjacent knee joint positions would lack robustness. Copyright © 2011 Elsevier Ltd. All rights reserved.
Guess, Trent M; Razu, Swithin; Jahandar, Amirhossein; Skubic, Marjorie; Huo, Zhiyu
2017-04-01
The Microsoft Kinect is becoming a widely used tool for inexpensive, portable measurement of human motion, with the potential to support clinical assessments of performance and function. In this study, the relative osteokinematic Cardan joint angles of the hip and knee were calculated using the Kinect 2.0 skeletal tracker. The pelvis segments of the default skeletal model were reoriented and 3-dimensional joint angles were compared with a marker-based system during a drop vertical jump and a hip abduction motion. Good agreement between the Kinect and marker-based system were found for knee (correlation coefficient = 0.96, cycle RMS error = 11°, peak flexion difference = 3°) and hip (correlation coefficient = 0.97, cycle RMS = 12°, peak flexion difference = 12°) flexion during the landing phase of the drop vertical jump and for hip abduction/adduction (correlation coefficient = 0.99, cycle RMS error = 7°, peak flexion difference = 8°) during isolated hip motion. Nonsagittal hip and knee angles did not correlate well for the drop vertical jump. When limited to activities in the optimal capture volume and with simple modifications to the skeletal model, the Kinect 2.0 skeletal tracker can provide limited 3-dimensional kinematic information of the lower limbs that may be useful for functional movement assessment.
Herbort, Mirco; Michel, Philipp; Raschke, Michael J; Vogel, Nils; Schulze, Martin; Zoll, Alexander; Fink, Christian; Petersen, Wolf; Domnick, Christoph
2017-03-01
Semitendinosus and gracilis muscles are frequently harvested for autologous tendon grafts for cruciate ligament reconstruction. This study investigated the joint-stabilizing effects of these hamstring muscles in cases of insufficiency of the medial collateral ligament (MCL). First, both the semitendinosus and gracilis muscles can actively stabilize the joint against valgus moments in the MCL-deficient knee. Second, the stabilizing influence of these muscles decreases with an increasing knee flexion angle. Controlled laboratory study. The kinematics was examined in 10 fresh-frozen human cadaveric knees using a robotic/universal force moment sensor system and an optical tracking system. The knee kinematics under 5- and 10-N·m valgus moments were determined in the different flexion angles of the (1) MCL-intact and (2) MCL-deficient knee using the following simulated muscle loads: (1) 0-N (idle) load, (2) 200-N semitendinosus (ST) load, and (3) 280-N (200/80-N) combined semitendinosus/gracilis (STGT) load. Cutting the MCL increased the valgus angle under all tested conditions and angles compared with the MCL-intact knee by 4.3° to 8.1° for the 5-N·m valgus moment and 6.5° to 11.9° for the 10-N·m valgus moment ( P < .01). The applied 200-N simulated ST load reduced the valgus angle significantly at 0°, 10°, 20°, and 30° of flexion under 5- and 10-N·m valgus moments ( P < .05). At 0°, 10°, and 20° of flexion, these values were close to those for the MCL-intact joint under the respective moments (both P > .05). The combined 280-N simulated STGT load significantly reduced the valgus angle in 0°, 10°, and 20° of flexion under 5- and 10-N·m valgus moments ( P < .05) to values near those for the intact joint (5 N·m: 0°, 10°; 10 N·m: 0°, 10°, 20°; P > .05). In 60° and 90° of flexion, ST and STGT loads did not decrease the resulting valgus angle of the MCL-deficient knee without hamstring loads ( P > .05 vs deficient; P = .0001 vs intact). In this human cadaveric study, semitendinosus and gracilis muscles successfully stabilize valgus moments applied to the MCL-insufficient knee when the knee is near extension. In the valgus-unstable knee, these data suggest that the hamstring muscles should be preserved in (multi-) ligament surgery when possible.
Hsu, Hsiu-Hao; Chou, You-Li; Lou, Shu-Zon; Huang, Ming-Jer; Chou, Paul Pei-Hsi
2011-03-01
Falling onto the outstretched hand is the most common cause of upper extremity injury. This study develops an experimental model for evaluating the shoulder load during a simulated forward fall onto one hand with three different forearm axially rotated postures, and examines the shoulder abduction angle and shoulder flexion angle in each case. Fifteen healthy young male subjects with an average age of 23.7 years performed a series of one-armed arrests from a height of 5 cm onto a force plate. The kinematics and kinetics of the upper extremity were analyzed for three different forearm postures, namely 45° externally rotated, non-rotated, and 45° internally rotated. The shoulder joint load and shoulder abduction/flexion angles were significantly dependent on the rotational posture of the forearm. The shoulder medio-lateral shear forces in the externally rotated group were found to be 1.61 and 2.94 times higher than those in the non-rotated and internally rotated groups, respectively. The shoulder flexion angles in the externally rotated, non-rotated and internally rotated groups were 0.6°, 8.0° and 19.2°, respectively, while the corresponding shoulder abduction angles were 6.1°, 34.1° and 46.3°, respectively. In falls onto the outstretched hand, an externally rotated forearm posture should be avoided in order to reduce the medio-lateral shear force acting on the shoulder joint. In falls of this type, a 45° internally rotated forearm posture represents the most effective fall strategy in terms of minimizing the risk of upper extremity injuries. Copyright © 2010 Elsevier Ltd. All rights reserved.
Gallagher, Kaitlin M; Callaghan, Jack P
2016-09-01
While alternating standing position on a sloped surface has proven successful at reducing low back pain during standing, the purpose of this study was to evaluate standing solely on a declining surface to isolate the influence of the postural change. Seventeen participants performed two 75-min prolonged standing occupational simulations- level ground and declining surface. Fifty-three percent of participants (9/17) were categorized as pain developers during the level ground standing condition. For these same pain developers, their average maximum pain scores were 58% lower during sloped standing. All participants showed greater hip flexion, trunk-to-thigh angle flexion, and posterior translation of the trunk center of gravity when standing on the sloped surface. These postural changes could cause the muscles crossing the hip posteriorly to increase passive stiffness and assist with stabilizing the pelvis. This study stresses the importance of hip kinematics, not just lumbar spine posture, in reducing prolonged standing induced low back pain. Copyright © 2016 Elsevier Ltd. All rights reserved.
Jackson, Timothy J; Peterson, Alexander B; Akeda, Masaki; Estess, Allyson; McGarry, Michelle H; Adamson, Gregory J; Lee, Thay Q
2016-03-01
A capsular shift procedure has been described for the treatment of hip instability; however, the biomechanical effects of such a shift are unknown. To create a cadaveric model of hip capsule laxity and evaluate the biomechanical effects of a capsular shift used to treat hip instability on this model. Controlled laboratory study. Eight cadaveric hips with an average age of 58.5 years were tested with a custom hip testing system in 6 conditions: intact, vented, instability, capsulotomy, side-to-side repair, and capsular shift. To create the hip model, the capsule was stretched in extension under 35 N·m of torque for 1 hour in neutral rotation. Measurements included internal and external rotation with 1.5 N·m of torque at 5 positions: 5° of extension and 0°, 15°, 30°, and 45° of flexion for each of the above conditions. The degree of maximum extension with 5 N·m of torque and the amount of femoral distraction with 40 N and 80 N of force were measured. Statistical analysis was performed by use of repeated-measures analysis of variance with Tukey post hoc analysis. The instability state significantly increased internal rotation at all flexion angles and increased distraction compared with the intact state. The capsulotomy condition resulted in significantly increased external rotation and internal rotation at all positions, increased distraction, and maximum extension compared with the intact state. The side-to-side repair condition restored internal rotation back to the instability state but not to the intact state at 5° of extension and 0° of flexion. The capsular shift state significantly decreased internal rotation compared with the instability state at 5° of extension and 0° and 15° of flexion. The capsular shift and side-to-side repair conditions had similar effects on external rotation at all flexion-extension positions. The capsular shift state decreased distraction and maximum extension compared with the instability state, but the side-to-side repair state did not. The hip capsular instability model was shown to have significantly greater total range of motion, external rotation, and extension compared with the intact condition. The greatest effects of capsular shift are seen with internal rotation, maximum extension, and distraction, with minimal effect on external rotation compared with the side-to side repair state. The biomechanical effects of the capsular shift procedure indicate that it can be used to treat hip capsular laxity by decreasing extension and distraction with minimal effect on external rotation. © 2015 The Author(s).
An Intelligent Remote Monitoring System for Total Knee Arthroplasty Patients.
Msayib, Yunus; Gaydecki, Patrick; Callaghan, Michael; Dale, Nicola; Ismail, Sheheera
2017-06-01
For the first six weeks following total knee arthroplasty (TKA), a patient will attend an outpatient clinic typically seen twice weekly. Here, an exercise regime is performed and improvement assessed using a hand held goniometer that measures the maximum angle of knee flexion, an important metric of progress. Additionally a series of daily exercises is performed at home, recorded in a diary. This protocol has problems. Patients must attend the hospital with assistance since they are not permitted to drive for six weeks following the procedure; appointments are sometimes missed; there are occasionally not enough physiotherapy appointment available; furthermore, it is difficult to be sure that patients are compliant with their exercises at home. The economic and social costs are therefore significant both to the patient and the health service. We describe here an automatic system that performs the monitoring of knee flexion within a domestic environment rather than in a hospital setting. It comprises a master and slave sensor unit that attach using Velcro straps to the thigh and shin above and below the operation wound. The patient performs the prescribed knee exercises whilst wearing the device, during which time it measures and records the angles of knee flexion. The device utilises the Global System for Mobile Communications (GSM) infrastructure to transmit data through the Internet to a secure hospital-based server using an on-board GSM modem. The clinician is then able to view and interpret the information from any computer with internet access and the software. The system does not require the patient to possess a mobile telephone, a computer, or have internet access; the necessary communications technology is completely integrated into the device.
The Shank-to-Vertical-Angle as a parameter to evaluate tuning of Ankle-Foot Orthoses.
Kerkum, Yvette L; Houdijk, Han; Brehm, Merel-Anne; Buizer, Annemieke I; Kessels, Manon L C; Sterk, Arjan; van den Noort, Josien C; Harlaar, Jaap
2015-09-01
The effectiveness of an Ankle-Foot Orthosis footwear combination (AFO-FC) may be partly dependent on the alignment of the ground reaction force with respect to lower limb joint rotation centers, reflected by joint angles and moments. Adjusting (i.e. tuning) the AFO-FC's properties could affect this alignment, which may be guided by monitoring the Shank-to-Vertical-Angle. This study aimed to investigate whether the Shank-to-Vertical-Angle during walking responds to variations in heel height and footplate stiffness, and if this would reflect changes in joint angles and net moments in healthy adults. Ten subjects walked on an instrumented treadmill and performed six trials while walking with bilateral rigid Ankle-Foot Orthoses. The AFO-FC heel height was increased, aiming to impose a Shank-to-Vertical-Angle of 5°, 11° and 20°, and combined with a flexible or stiff footplate. For each trial, the Shank-to-Vertical-Angle, joint flexion-extension angles and net joint moments of the right leg at midstance were averaged over 25 gait cycles. The Shank-to-Vertical-Angle significantly increased with increasing heel height (p<0.001), resulting in an increase in knee flexion angle and internal knee extensor moment (p<0.001). The stiff footplate reduced the effect of heel height on the internal knee extensor moment (p=0.030), while the internal ankle plantar flexion moment increased (p=0.035). Effects of heel height and footplate stiffness on the hip joint were limited. Our results support the potential to use the Shank-to-Vertical-Angle as a parameter to evaluate AFO-FC tuning, as it is responsive to changes in heel height and reflects concomitant changes in the lower limb angles and moments. Copyright © 2015 Elsevier B.V. All rights reserved.
Mechanical Characteristics of Reflex Durign Upright Posture in Paralyzed Subjects
NASA Astrophysics Data System (ADS)
Kim, Yongchul; Youm, Youngil; Lee, Bumsuk; Kim, Youngho; Choi, Hyeonki
The characteristics of flexor reflexes have been investigated in the previous studies with human subjects who were seated or supine position. However, researchers did not describe how the spinal circuits are used in different hip angles for paralyzed subjects, such as the standing position with walker or cane. In upright posture the compatibility between a flexor reflex of leg and body balance is a special problem for lower limb injured subjects. Therefore, the purpose of this study was to investigate the effects of hip angle change on the flexor reflex evoked in standing paralyzed subjects supported by walker. In this study, six spinal cord injured and four stroke subjects were recruited through the inpatient physical therapy clinics of Korea national rehabilitation hospital. A single axis electronic goniometer was mounted on the lateral side of the hip joint of the impaired limb to record movements in the sagittal plane at this joint. The electronic goniometer was connected to a data acquisition system, through amplifiers to a computer. Since subject' posture influenced characteristics of the flexion reflex response, the subjects were supported in an upright posture by the help of parallelogram walder. Two series of tests were performed on each leg. The first series of the tests investigated the influence of hip angle during stationary standing posture on flexion reflex response. The hip angle was adjusted by the foot plate. The second examined the effect of the voluntary action of subject on swing motion during the gait. The electrically induced flexion reflex simultaneously produced the flexion of the hip, knee and dorsiflexion of the ankle enabling the swing phase of walking. Form the experimental results we observed that the reflex response of hip joint was largerwith the hip in the extended position than in the flexed position during standing posture. Under voluntary movement on flexion reflex during gaint, the peak hip angle induced by stimulation was increased in spinal cord injury and stroke patients by subject' voluntary movement.
Mulcahey, Mary K.; Monchik, Keith O.; Yongpravat, Charlie; Badger, Gary J.; Fadale, Paul D.; Hulstyn, Michael J.; Fleming, Braden C.
2011-01-01
The purpose of this study was to compare tibiofemoral (TF) kinematics and TF compressive stresses between single bundle- (SB-) and double bundle-ACL reconstruction (DB-ACLR) during simulated squatting. Twelve matched pairs of fresh frozen cadaver knees were utilized. A simulated squat through 100° of knee flexion was performed in the ACL-intact joint. The ACL was transected and SB- and DB-ACLR procedures were performed in one knee of each pair. The squat was repeated. Knee kinematics were measured using a motion tracking system and the TF compressive forces were measured using thin film pressure sensors. The posterior shifts of the tibia for SB- and DB-ACLR knees were significantly greater than the ACL-intact condition for knee flexion angles 0° to 40° (p<.05). However, there was no difference between the SB- and DB-ACLR knees at any flexion angle (0° to 100°; p=.37). SB- and DB-ACLR knees had greater IE rotation than intact knees from 90° through 50° of flexion (p<.05), but not between 40° and full extension. There was no difference between SB- and DB-ACLR knees (p=.68). The TF compressive stresses of the DB-ACLR were significantly lower than intact for all angles except 10° (p=.06), whereas SB-ACLR knees did not differ from intact at flexion angles between 30° and 50° (p>.32). There were no significant differences between the two reconstruction conditions (p=.74). This study showed that there was no difference in the TF kinematics or compressive stresses between SB- and DB-ACLR, and only minor differences when compared to the intact state. PMID:21696962
NASA Astrophysics Data System (ADS)
Sewell, Tanzania S.; Piacsek, Kelly L.; Heckel, Beth A.; Sabol, John M.
2011-03-01
The current imaging standard for diagnosis and monitoring of knee osteoarthritis (OA) is projection radiography. However radiographs may be insensitive to markers of early disease such as osteophytes and joint space narrowing (JSN). Relative to standard radiography, digital X-ray tomosynthesis (DTS) may provide improved visualization of the markers of knee OA without the interference of superimposed anatomy. DTS utilizes a series of low-dose projection images over an arc of +/-20 degrees to reconstruct tomographic images parallel to the detector. We propose that DTS can increase accuracy and precision in JSN quantification. The geometric accuracy of DTS was characterized by quantifying joint space width (JSW) as a function of knee flexion and position using physical and anthropomorphic phantoms. Using a commercially available digital X-ray system, projection and DTS images were acquired for a Lucite rod phantom with known gaps at various source-object-distances, and angles of flexion. Gap width, representative of JSW, was measured using a validated algorithm. Over an object-to-detector-distance range of 5-21cm, a 3.0mm gap width was reproducibly measured in the DTS images, independent of magnification. A simulated 0.50mm (+/-0.13) JSN was quantified accurately (95% CI 0.44-0.56mm) in the DTS images. Angling the rods to represent knee flexion, the minimum gap could be precisely determined from the DTS images and was independent of flexion angle. JSN quantification using DTS was insensitive to distance from patient barrier and flexion angle. Potential exists for the optimization of DTS for accurate radiographic quantification of knee OA independent of patient positioning.
Debandi, Aníbal; Maeyama, Akira; Hoshino, Yuichi; Asai, Shigehiro; Goto, Bunsei; Smolinski, Patrick; Fu, Freddie H
2016-11-01
To evaluate the effect of knee flexion angle for hamstring graft fixation, full extension (FE), or 30°, on acceleration of the knee motion during pivot-shift testing after either anatomic or nonanatomic anterior cruciate ligament (ACL) reconstruction using triaxial accelerometry. Two types of ACL reconstructions (anatomic and nonanatomic) using 2 different angles of knee flexion during graft fixation (FE and 30°) were performed on 12 fresh-frozen human knees making 4 groups: anatomic-FE, anatomic-30°, nonanatomic-FE, and nonanatomic-30°. Manual pivot-shift testing was performed at ACL-intact, ACL-deficient, and ACL-reconstructed conditions. Three-dimensional acceleration of knee motion was recorded using a triaxial accelerometer. The anatomic-30° group showed the smallest overall magnitude of acceleration among the ACL-reconstructed groups (P = .0039). There were no significant differences among the anatomic-FE group, the nonanatomic-FE group, and the nonantomic-30° group (anatomic-FE vs nonanatomic-FE, P = .1093; anatomic-FE vs nonanatomic-30°, P = .8728; and nonanatomic-FE vs nonanatomic-30°, P = .1093). After ACL transection, acceleration was reduced by ACL reconstruction with the exception of the nonanatomic-FE group that did not show a significant difference when compared with the ACL-deficient (P = .4537). The anatomic ACL reconstruction with the graft fixed at 30° of knee flexion better restored rotational knee stability compared with FE. An ACL graft fixed with the knee at FE in anatomic position did not show a significant difference compared with the nonanatomic ACL reconstructions. Knee flexion angle at the time of graft fixation for ACL reconstruction can be considered to maximize the rotational knee stability. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Jacobsen, Julie S; Nielsen, Dennis B; Sørensen, Henrik; Søballe, Kjeld; Mechlenburg, Inger
2014-01-01
Background and purpose — Hip dysplasia can be treated with periacetabular osteotomy (PAO). We compared joint angles and joint moments during walking and running in young adults with hip dysplasia prior to and 6 and 12 months after PAO with those in healthy controls. Patients and methods — Joint kinematics and kinetics were recorded using a 3-D motion capture system. The pre- and postoperative gait characteristics quantified as the peak hip extension angle and the peak joint moment of hip flexion were compared in 23 patients with hip dysplasia (18–53 years old). Similarly, the gait patterns of the patients were compared with those of 32 controls (18–54 years old). Results — During walking, the peak hip extension angle and the peak hip flexion moment were significantly smaller at baseline in the patients than in the healthy controls. The peak hip flexion moment increased 6 and 12 months after PAO relative to baseline during walking, and 6 months after PAO relative to baseline during running. For running, the improvement did not reach statistical significance at 12 months. In addition, the peak hip extension angle during walking increased 12 months after PAO, though not statistically significantly. There were no statistically significant differences in peak hip extension angle and peak hip flexion moment between the patients and the healthy controls after 12 months. Interpretation — Walking and running characteristics improved after PAO in patients with symptomatic hip dysplasia, although gait modifications were still present 12 months postoperatively. PMID:25191933
Evaluation of the Microsoft Kinect for screening ACL injury.
Stone, Erik E; Butler, Michael; McRuer, Aaron; Gray, Aaron; Marks, Jeffrey; Skubic, Marjorie
2013-01-01
A study was conducted to evaluate the use of the skeletal model generated by the Microsoft Kinect SDK in capturing four biomechanical measures during the Drop Vertical Jump test. These measures, which include: knee valgus motion from initial contact to peak flexion, frontal plane knee angle at initial contact, frontal plane knee angle at peak flexion, and knee-to-ankle separation ratio at peak flexion, have proven to be useful in screening for future knee anterior cruciate ligament (ACL) injuries among female athletes. A marker-based Vicon motion capture system was used for ground truth. Results indicate that the Kinect skeletal model likely has acceptable accuracy for use as part of a screening tool to identify elevated risk for ACL injury.
Gautam, Arvind; Callejas, Miguel A; Acharyya, Amit; Acharyya, Swati Ghosh
2018-05-01
This study introduced a shape memory alloy (SMA)-based smart knee spacer for total knee arthroplasty (TKA). Subsequently, a 3D CAD model of a smart tibial component of TKA was designed in Solidworks software, and verified using a finite element analysis in ANSYS Workbench. The two major properties of the SMA (NiTi), the pseudoelasticity (PE) and shape memory effect (SME), were exploited, modelled, and analysed for a TKA application. The effectiveness of the proposed model was verified in ANSYS Workbench through the finite element analysis (FEA) of the maximum deformation and equivalent (von Mises) stress distribution. The proposed model was also compared with a polymethylmethacrylate (PMMA)-based spacer for the upper portion of the tibial component for three subjects with body mass index (BMI) of 23.88, 31.09, and 38.39. The proposed SMA -based smart knee spacer contained 96.66978% less deformation with a standard deviation of 0.01738 than that of the corresponding PMMA based counterpart for the same load and flexion angle. Based on the maximum deformation analysis, the PMMA-based spacer had 30 times more permanent deformation than that of the proposed SMA-based spacer for the same load and flexion angle. The SME property of the lower portion of the tibial component for fixation of the spacer at its position was verified by an FEA in ANSYS. Wherein, a strain life-based fatigue analysis was performed and tested for the PE and SME built spacers through the FEA. Therefore, the SMA-based smart knee spacer eliminated the drawbacks of the PMMA-based spacer, including spacer fracture, loosening, dislocation, tilting or translation, and knee subluxation. Copyright © 2018. Published by Elsevier Ltd.
Biomechanical analysis of the single‐leg decline squat
Zwerver, J; Bredeweg, S W; Hof, A L
2007-01-01
Background The single‐leg squat on a 25° decline board has been described as a clinical assessment tool and as a rehabilitation exercise for patients with patellar tendinopathy. Several assumptions have been made about its working mechanism on patellar load and patellofemoral forces, but these are not substantiated by biomechanical evaluations. Aim To investigate knee moment and patellofemoral contact force as a function of decline angle in the single‐leg squat. Methods Five subjects performed single‐leg eccentric squats at decline angles of 0°, 5°, 10°, 15°, 20° and 25° (with/without a backpack of 10 kg), and 30° on a board that was placed over a forceplate. Kinematic and forceplate data were recorded by the Optotrak system. Joint moments of ankle, knee and hip were calculated by two‐dimensional inverse dynamics. Results Knee moment increased by 40% at decline angles of 15° and higher, whereas hip and ankle moment decreased. Maximum knee and ankle angles increased with steeper decline. With a 10 kg backpack at 25° decline, the knee moment was 23% higher than unloaded. Both patellar tendon and patellofemoral forces increased with higher decline angles, but beyond 60°, the patellofemoral force rose steeper than the tendon force. Conclusions All single‐leg squats at decline angles >15° result in 40% increase in maximum patellar tendon force. In knee flexions >60°, patellofemoral forces increase more than patellar tendon forces. Higher tendon load can be achieved by the use of a backpack with extra weight. PMID:17224441
NASA Astrophysics Data System (ADS)
Van Volkinburg, Kyle R.; Nguyen, Thao; Pegan, Jonathan D.; Khine, Michelle; Washington, Gregory N.
2016-04-01
The shape memory polymer polystyrene (PS) has been used to create complex hierarchical wrinkling in the fabrication of stretchable thin film bimetallic sensors ideal for wearable based gesture monitoring applications. The film has been bonded to the elastomer polydimethylsiloxane (PDMS) and operates as a strain gauge under the general notion of geometric piezoresistivity. The film was subject to tensile, cyclic, and step loading conditions in order to characterize its dynamic behavior. To measure the joint angle of the metacarpophalangeal (MCP) joint on the right index finger, the sensor was adhered to a fitted golf glove above said joint and a motion study was conducted. At maximum joint angle the sensor experienced roughly 23.5% strain. From the study it was found that two simple curves, one while the finger was in flexion and the other while the finger was in extension, were able to predict the joint angle from measured voltage with an average error of 2.99 degrees.
LaPrade, Robert F; Smith, Sean D; Wilson, Katharine J; Wijdicks, Coen A
2015-10-01
Counteracting posterior translation of the tibia with an anterior force on the posterior proximal tibia has been demonstrated clinically to improve posterior knee laxity following posterior cruciate ligament (PCL) injury. This study quantified forces applied to the posterior proximal tibia by two knee braces designed for treatment of PCL injuries. The forces applied by two knee braces to the posterior proximal tibia and in vivo three-dimensional knee kinematics of six adult, male, healthy volunteer subjects (mean ± standard deviation: height, 182.5 ± 5.2 cm; body mass, 83.2 ± 9.3 kg; body mass index, 24.9 ± 1.5 kg/m(2); age, 25.8 ± 2.9 years) were measured using a custom pressure mapping technique and traditional surface marker motion capture techniques, while subjects performed three functional activities. The activities included seated unloaded knee flexion, squatting, and stair descent in a new generation dynamic force (DF) PCL brace and a static force (SF) PCL brace. During unloaded flexion at the lowest force level setting, the force applied by the DF brace increased as a function of flexion angle (slope = 0.7 N/°; p < 0.001) compared to the SF brace effect. Force applied by the SF brace did not significantly change as a function of flexion angle (slope = 0.0 N/°; n.s.). By 45° of flexion, the average force applied by the DF brace (48.1 N) was significantly larger (p < 0.001) than the average force applied by the SF brace (25.0 N). The difference in force continued to increase as flexion angle increased. During stair descent, average force (mean ± standard deviation) at toe off was significantly higher (p = 0.013) for the DF brace (78.7 ± 21.6 N) than the SF brace (37.3 ± 7.2 N). Similar trends were observed for squatting and for the higher force level settings. The DF brace applied forces to the posterior proximal tibia that dynamically increased with increased flexion angle. Additionally, the DF brace applied significantly larger forces at higher flexion angles compared to the SF brace where the PCL is known to experience larger in situ forces. Clinical studies are necessary to determine whether the loading characteristics of the DF brace, which more closely replicated the in situ loading profile of the native PCL, results in long-term improved posterior knee laxity following PCL injury. II.
Withrow, Thomas J; Huston, Laura J; Wojtys, Edward M; Ashton-Miller, James A
2006-02-01
An instrumented cadaveric knee construct was used to quantify the association between impact force, quadriceps force, knee flexion angle, and anterior cruciate ligament relative strain in simulated unipedal jump landings. Anterior cruciate ligament strain will correlate with impact force, quadriceps force, and knee flexion angle. Descriptive laboratory study. Eleven cadaveric knees (age, 70.8 [19.3] years; 5 male; 6 female) were mounted in a custom fixture with the tibia and femur secured to a triaxial load cell. Quadriceps, hamstring, and gastrocnemius muscle forces were simulated using pretensioned steel cables (stiffness, 7 kN/cm), and the quadriceps tendon force was measured using a load cell. Mean strain on the anteromedial bundle of the anterior cruciate ligament was measured using a DVRT. With the knee in 25 degrees of flexion, the construct was vertically loaded by an impact force initially directed 4 cm posterior to the knee joint center. Tibiofemoral kinematics was measured using a 3D optoelectronic tracking system. The increase in anterior cruciate ligament relative strain was proportional to the increase in quadriceps force (r(2) = 0.74; P < .00001) and knee flexion angle (r(2) = 0.88; P < .00001) but was not correlated with the impact force (r(2) = 0.009; P = .08). The increase in knee flexion and quadriceps force during this simulated 1-footed landing strongly influenced the relative strain on the anteromedial bundle of the anterior cruciate ligament. These results suggest that even in the presence of knee flexor muscle forces, the increase in quadriceps force required to prevent the knee from flexing during landing can place the anterior cruciate ligament at risk for large strains.
A radiographic assessment of lumbar spine posture in four different upright standing positions.
Gallagher, Kaitlin M; Sehl, Michael; Callaghan, Jack P
2016-08-01
Approximately 50% of a sample population will develop prolonged standing induced low back pain. The cause of this pain may be due to their lumbar spine posture. The purpose of this study was to investigate differences in lumbar posture between 17 participants categorized as a pain or non-pain developers during level ground standing. A secondary purpose was to evaluate the influence of two standing aids (an elevated surface to act as a foot rest and declined sloped surface) on lumbopelvic posture. Four sagittal plane radiographs were taken: a normal standing position on level ground, when using an elevated foot rest, using a declined sloped surface, and maximum lumbar spine extension as a reference posture. Lumbosacral lordosis, total lumbar lordosis, and L1/L2 and L5/S1 intervertebral joint angles were measured on each radiograph. There was a significant difference between the lumbosacral lordosis angle and L5/S1 angles in upright versus maximum extension; however, this was independent of pain group. The elevated surface was most effective at causing lumbosacral spine flexion. Potentially successful postures for eliminating low back pain during prolonged standing mainly influence the lower lumbar lordosis. Future work should assess the influence of hip posture on low back pain development during standing. Copyright © 2016 Elsevier Ltd. All rights reserved.
Eitzen, I; Eitzen, TJ; Holm, I; Snyder-Mackler, L; Risberg, MA
2011-01-01
Background Isokinetic muscle strength tests using the peak torque value is the most frequently included quadriceps muscle strength measurement for anterior cruciate ligament (ACL) injured subjects. Aims The purpose of this study was to investigate quadriceps muscle performance during the whole isokinetic curve in ACL deficient subjects classified as potential copers or non-copers, and investigate whether these curve profiles were associated with single-leg hop performance. We hypothesized that quadriceps muscle torque at other knee flexion angles than peak torque would give more information about quadriceps muscle strength deficits. Furthermore, we hypothesized that there would be significant torque differences between potential copers and non-copers, and a significant relationship between angle specific torque values and single-leg hop performance. Study Design Cross-sectional study; Level of evidence, 2 Methods Seventy-six individuals with a complete unilateral ACL rupture within the last 3 months were included. The subjects were classified into potential copers and non-copers according to the criteria from Fitzgerald et al12. Isokinetic quadriceps muscle tests were performed at 60°/sec (Biodex 6000). Mean torque values were calculated for peak torque as well as for specific knee flexion angles. The one-leg hop and the 6 meter timed hop tests were included and symmetry indices were used. Results The peak torque value did not identify the largest quadriceps muscle strength deficit. Rather, these were established at knee flexion angles of less than 40°. There were significant differences in angle specific torque values between potential copers and non-copers (p<0.05). Moderate to strong associations were disclosed between angle specific torque values and single-leg hop performance, but only for non-copers (r≥0.32– 0.58). Conclusions Angle specific quadriceps muscle torque values of less than 40° of knee flexion provide more information on the quadriceps strength deficits after ACL injury compared to the commonly used peak torque values. PMID:20110458
Lower extremity mechanics of iliotibial band syndrome during an exhaustive run.
Miller, Ross H; Lowry, Jennifer L; Meardon, Stacey A; Gillette, Jason C
2007-09-01
Injury patterns in distance running may be related to kinematic adjustments induced by fatigue. The goal was to measure changes in lower extremity mechanics during an exhaustive run in individuals with and without a history of iliotibial band syndrome (ITBS). Sixteen recreational runners ran to voluntary exhaustion on a treadmill at a self-selected pace. Eight runners had a history of ITBS. Twenty-three reflective marker positions were recorded by an eight-camera 120 Hz motion capture system. Joint angles during stance phase were exported to a musculoskeletal model (SIMM) with the iliotibial band (ITB) modeled as a passive structure to estimate strain in the ITB. For ITBS runners, at the end of the run: (1) knee flexion at heel-strike was higher than control (20.6 degrees versus 15.3 degrees, p=0.01); (2) the number of knees with predicted ITB impingment upon the lateral femoral epicondyle increased from 6 to 11. Strain in the ITB was higher in the ITBS runners throughout all of stance. Maximum foot adduction in the ITBS runners was higher versus control at the start of the run (p=0.003). Maximum foot inversion (p=0.03) and maximum knee internal rotation velocity (p=0.02) were higher versus control at the end of the run. In conclusion, ITB mechanics appear to be related to changes in knee flexion at heel-strike and internal rotation of the leg. These observations may suggest kinematic discriminators for clinical assessment.
Laugharne, Edward; Bali, Navi; Purushothamdas, Sanjay; Almallah, Faris; Kundra, Rik
2016-01-01
Purpose The purpose of this study was to investigate the impact of varying knee flexion and quadriceps activity on patellofemoral indices measured on magnetic resonance imaging (MRI). Materials and Methods MRI of the knee was performed in 20 patients for indications other than patellar or patellofemoral pathology. Axial and sagittal sequences were performed in full extension of the knee with the quadriceps relaxed, full extension of the knee with the quadriceps contracted, 30° flexion of the knee with the quadriceps relaxed, and 30° flexion with the quadriceps contracted. Bisect offset, patella tilt angle, Insall-Salvati ratio and Caton-Deschamps index were measured. Results With the knee flexed to 30° and quadriceps relaxed, the mean values of patellar tilt angle, bisect offset, Insall-Salvati ratio and Caton-Deschamps index were all within normal limits. With the knee extended and quadriceps contracted, the mean patellar tilt angle (normal value, <15°) was 14.6° and the bisect offset (normal value, <65%) was 65%, while the Caton-Deschamps index was 1.34 (normal range, 0.6 to 1.3). With the knee extended and quadriceps relaxed, the mean Caton-Deschamps index was 1.31. Conclusions MRI scanning of the knee in extension with the quadriceps contracted leads to elevated patellofemoral indices. MRI taken with the knee in 30° of flexion allows more reliable assessment of the patellofemoral joint and minimises the confounding effect of quadriceps contraction. PMID:27894177
King, Mark; Hau, Agnes; Blenkinsop, Glen
2017-07-01
Recreational tennis players tend to have higher incidence of tennis elbow, and this has been hypothesised to be related to one-handed backhand technique and off-centre ball impacts on the racket face. This study aimed to investigate for a range of participants the effect of off-longitudinal axis and off-lateral axis ball-racket impact locations on racket and forearm joint angle changes immediately following impact in one-handed tennis backhand groundstrokes. Three-dimensional racket and wrist angular kinematic data were recorded for 14 university tennis players each performing 30 "flat" one-handed backhand groundstrokes. Off-longitudinal axis ball-racket impact locations explained over 70% of the variation in racket rotation about the longitudinal axis and wrist flexion/extension angles during the 30 ms immediately following impact. Off-lateral axis ball-racket impact locations had a less clear cut influence on racket and forearm rotations. Specifically off-longitudinal impacts below the longitudinal axis forced the wrist into flexion for all participants with there being between 11° and 32° of forced wrist flexion for an off-longitudinal axis impact that was 1 ball diameter away from the midline. This study has confirmed that off-longitudinal impacts below the longitudinal axis contribute to forced wrist flexion and eccentric stretch of the wrist extensors and there can be large differences in the amount of forced wrist flexion from individual to individual and between strokes with different impact locations.
Tate, Jeremiah; Suckut, Tell; Wages, Jensen; Lyles, Heather; Perrin, Benjamin
2017-06-01
Only a small amount of evidence exists linking hip abductor weakness to dynamic knee valgus during static and dynamic activities. The associations of hip extensor strength and hip kinematics during the landing of a single leg hop are not known. Purpose: To determine if relationships exist between hip extensor and abductor strength and hip kinematics in both involved and uninvolved limb during the landing phase of a single leg hop in recreational athletes post anterior cruciate ligament (ACL) reconstruction. The presence of similar associations was also evaluated in healthy recreational athletes. Controlled Laboratory Study; Cross-sectional. Twenty-four recreational college-aged athletes participated in the study (12 post ACL reconstruction; 12 healthy controls). Sagittal and frontal plane hip kinematic data were collected for five trials during the landing of a single leg hop. Hip extensor and abductor isometric force production was measured using a hand-held dynamometer and normalized to participants' height and weight. Dependent and independent t-tests were used to analyze for any potential differences in hip strength or kinematics within and between groups, respectively. Pearson's r was used to demonstrate potential associations between hip strength and hip kinematics for both limbs in the ACL group and the right limb in the healthy control group. Independent t-tests revealed that participants post ACL reconstruction exhibited less hip extensor strength (0.18 N/Ht*BW vs. 0.25 N/Ht*BW, p=<.01) and landed with greater hip adduction (9.0 º vs. 0.8 º, p=<.01) compared with their healthy counterparts. In the ACL group, Pearson's r demonstrated a moderate and indirect relationship ( r =-.62, p=.03) between hip extensor strength and maximum hip abduction/adduction angle in the involved limb. A moderate and direct relationship between hip abductor strength and maximum hip flexion angle was demonstrated in the both the involved ( r =.62) and uninvolved limb ( r =.65, p=.02). No significant associations were demonstrated between hip extensor or abductor strength and hip flexion and/or abduction/adduction angles in the healthy group. The results suggest that hip extensors may play a role in minimizing hip adduction in the involved limb while the hip abductors seem to play a role in facilitating hip flexion during the landing phase of a single leg hop for both limbs following ACL reconstruction. Researchers and clinicians alike should consider the importance of the hip extensors in playing a more prominent role in contributing to frontal plane motion. Level 2a.
Improving Kinematic Accuracy of Soft Wearable Data Gloves by Optimizing Sensor Locations
Kim, Dong Hyun; Lee, Sang Wook; Park, Hyung-Soon
2016-01-01
Bending sensors enable compact, wearable designs when used for measuring hand configurations in data gloves. While existing data gloves can accurately measure angular displacement of the finger and distal thumb joints, accurate measurement of thumb carpometacarpal (CMC) joint movements remains challenging due to crosstalk between the multi-sensor outputs required to measure the degrees of freedom (DOF). To properly measure CMC-joint configurations, sensor locations that minimize sensor crosstalk must be identified. This paper presents a novel approach to identifying optimal sensor locations. Three-dimensional hand surface data from ten subjects was collected in multiple thumb postures with varied CMC-joint flexion and abduction angles. For each posture, scanned CMC-joint contours were used to estimate CMC-joint flexion and abduction angles by varying the positions and orientations of two bending sensors. Optimal sensor locations were estimated by the least squares method, which minimized the difference between the true CMC-joint angles and the joint angle estimates. Finally, the resultant optimal sensor locations were experimentally validated. Placing sensors at the optimal locations, CMC-joint angle measurement accuracies improved (flexion, 2.8° ± 1.9°; abduction, 1.9° ± 1.2°). The proposed method for improving the accuracy of the sensing system can be extended to other types of soft wearable measurement devices. PMID:27240364
A Study of Knee Joint Kinematics and Mechanics using a Human FE Model.
Kitagawa, Yuichi; Hasegawa, Junji; Yasuki, Tsuyoshi; Iwamoto, Masami; Miki, Kazuo
2005-11-01
Posterior translation of the tibia with respect to the femur can stretch the posterior cruciate ligament (PCL). Fifteen millimeters of relative displacement between the femur and tibia is known as the Injury Assessment Reference Value (IARV) for the PCL injury. Since the anterior protuberance of the tibial plateau can be the first site of contact when the knee is flexed, the knee bolster is generally designed with an inclined surface so as not to directly load the projection in frontal crashes. It should be noted, however, that the initial flexion angle of the occupant knee can vary among individuals and the knee flexion angle can change due to the occupant motion. The behavior of the tibial protuberance related to the knee flexion angle has not been described yet. The instantaneous angle of the knee joint at the timing of restraining the knee should be known to manage the geometry and functions of knee restraint devices. The purposes of this study are first to understand the kinematics of the knee joint during flexion, and second to characterize the mechanics of the knee joint under anterior-posterior loading. A finite element model of the knee joint, extracted from the Total Human Model for Safety (THUMS), was used to analyze the mechanism. The model was validated against kinematics and mechanical responses of the human knee joint. By tracking the relative positions and angles between the patella and the tibia in a knee flexing simulation, the magnitude of the tibial anterior protuberance was described as a function of the knee joint angle. The model revealed that the mechanics of the knee joint was characterized as a combination of stiffness of the patella-femur structure and the PCL It was also found that the magnitude of the tibial anterior protuberance determined the amount of initial stretch of the PCL in anterior-posterior loading. Based on the knee joint kinematics and mechanics, an interference boundary was proposed for different knee flexion angles, so as not to directly load the anterior protuberance of the tibial plateau in restraining of the knee. A frontal crash simulation was performed using a partial vehicle model with the THUMS seated. The performance and effects of the knee airbag, as one of the candidates for knee restraint devices, were evaluated through the simulation.
Influence of Joint Angle on EMG-Torque Model During Constant-Posture, Torque-Varying Contractions.
Liu, Pu; Liu, Lukai; Clancy, Edward A
2015-11-01
Relating the electromyogram (EMG) to joint torque is useful in various application areas, including prosthesis control, ergonomics and clinical biomechanics. Limited study has related EMG to torque across varied joint angles, particularly when subjects performed force-varying contractions or when optimized modeling methods were utilized. We related the biceps-triceps surface EMG of 22 subjects to elbow torque at six joint angles (spanning 60° to 135°) during constant-posture, torque-varying contractions. Three nonlinear EMG σ -torque models, advanced EMG amplitude (EMG σ ) estimation processors (i.e., whitened, multiple-channel) and the duration of data used to train models were investigated. When EMG-torque models were formed separately for each of the six distinct joint angles, a minimum "gold standard" error of 4.01±1.2% MVC(F90) resulted (i.e., error relative to maximum voluntary contraction at 90° flexion). This model structure, however, did not directly facilitate interpolation across angles. The best model which did so achieved a statistically equivalent error of 4.06±1.2% MVC(F90). Results demonstrated that advanced EMG σ processors lead to improved joint torque estimation as do longer model training durations.
Does trampoline or hard surface jumping influence lower extremity alignment?
Akasaka, Kiyokazu; Tamura, Akihiro; Katsuta, Aoi; Sagawa, Ayako; Otsudo, Takahiro; Okubo, Yu; Sawada, Yutaka; Hall, Toby
2017-12-01
[Purpose] To determine whether repetitive trampoline or hard surface jumping affects lower extremity alignment on jump landing. [Subjects and Methods] Twenty healthy females participated in this study. All subjects performed a drop vertical jump before and after repeated maximum effort trampoline or hard surface jumping. A three-dimensional motion analysis system and two force plates were used to record lower extremity angles, moments, and vertical ground reaction force during drop vertical jumps. [Results] Knee extensor moment after trampoline jumping was greater than that after hard surface jumping. There were no significant differences between trials in vertical ground reaction force and lower extremity joint angles following each form of exercise. Repeated jumping on a trampoline increased peak vertical ground reaction force, hip extensor, knee extensor moments, and hip adduction angle, while decreasing hip flexion angle during drop vertical jumps. In contrast, repeated jumping on a hard surface increased peak vertical ground reaction force, ankle dorsiflexion angle, and hip extensor moment during drop vertical jumps. [Conclusion] Repeated jumping on the trampoline compared to jumping on a hard surface has different effects on lower limb kinetics and kinematics. Knowledge of these effects may be useful in designing exercise programs for different clinical presentations.
Does trampoline or hard surface jumping influence lower extremity alignment?
Akasaka, Kiyokazu; Tamura, Akihiro; Katsuta, Aoi; Sagawa, Ayako; Otsudo, Takahiro; Okubo, Yu; Sawada, Yutaka; Hall, Toby
2017-01-01
[Purpose] To determine whether repetitive trampoline or hard surface jumping affects lower extremity alignment on jump landing. [Subjects and Methods] Twenty healthy females participated in this study. All subjects performed a drop vertical jump before and after repeated maximum effort trampoline or hard surface jumping. A three-dimensional motion analysis system and two force plates were used to record lower extremity angles, moments, and vertical ground reaction force during drop vertical jumps. [Results] Knee extensor moment after trampoline jumping was greater than that after hard surface jumping. There were no significant differences between trials in vertical ground reaction force and lower extremity joint angles following each form of exercise. Repeated jumping on a trampoline increased peak vertical ground reaction force, hip extensor, knee extensor moments, and hip adduction angle, while decreasing hip flexion angle during drop vertical jumps. In contrast, repeated jumping on a hard surface increased peak vertical ground reaction force, ankle dorsiflexion angle, and hip extensor moment during drop vertical jumps. [Conclusion] Repeated jumping on the trampoline compared to jumping on a hard surface has different effects on lower limb kinetics and kinematics. Knowledge of these effects may be useful in designing exercise programs for different clinical presentations. PMID:29643592
Control of speed during the double poling technique performed by elite cross-country skiers.
Lindinger, Stefan Josef; Stöggl, Thomas; Müller, Erich; Holmberg, Hans-Christer
2009-01-01
Double poling (DP) as a main technique in cross-country skiing has developed substantially over the last 15 yr. The purpose of the present study was to analyze the question, "How do modern elite skiers control DP speed?" Twelve male elite cross-country skiers roller skied using DP at 9, 15, 21, and 27 km.h(-1) and maximum velocity (V(max)). Cycle characteristics, pole and plantar forces, and elbow, hip, and knee joint angles were analyzed. Both poling frequency and cycle length increased up to 27 km.h (-1)(P < 0.05), with a further increase in poling frequency at V(max) (P < 0.05). Peak pole force, rate of force development, and rearfoot plantar force increased with submaximal velocities (V(sm)), whereas poling time and time-to-peak pole force gradually shortened (P < 0.05). Changes in elbow joint kinematics during the poling phase were characterized by a decreased angle minimum and an increased flexion and extension ranges of motion as well as angular velocities across V(sm) (P < 0.05), with no further changes at V(max). Hip and knee joint kinematics adapted across V(sm) by 1) decreasing angles at pole plant and angle minima during the poling phase, 2) increasing the ranges of motion and angular velocities during the flexion phases occurring around pole plant, and 3) increasing extension ranges of motion and angular velocities during the recovery phase (all P values <0.05), with no further changes at V(max). Elite skiers control DP speed by increasing both poling frequency and cycle length; the latter is achieved by increased pole force despite reduced poling time. Adaptation to higher speeds was assisted by an increased range of motion, smaller angle minima, and higher angular velocities in the elbow, the hip, and the knee joints.
Conlisk, N.; Gray, H.; Pankaj, P.; Howie, C. R.
2012-01-01
Objectives Orthopaedic surgeons use stems in revision knee surgery to obtain stability when metaphyseal bone is missing. No consensus exists regarding stem size or method of fixation. This in vitro study investigated the influence of stem length and method of fixation on the pattern and level of relative motion at the bone–implant interface at a range of functional flexion angles. Methods A custom test rig using differential variable reluctance transducers (DVRTs) was developed to record all translational and rotational motions at the bone–implant interface. Composite femurs were used. These were secured to permit variation in flexion angle from 0° to 90°. Cyclic loads were applied through a tibial component based on three peaks corresponding to 0°, 10° and 20° flexion from a normal walking cycle. Three different femoral components were investigated in this study for cementless and cemented interface conditions. Results Relative motions were found to increase with flexion angle. Stemmed implants reduced relative motions in comparison to stemless implants for uncemented constructs. Relative motions for cemented implants were reduced to one-third of their equivalent uncemented constructs. Conclusions Stems are not necessary for cemented implants when the metaphyseal bone is intact. Short cemented femoral stems confer as much stability as long uncemented stems. PMID:23610659
Kimura, Yuka; Ishibashi, Yasuyuki; Tsuda, Eiichi; Yamamoto, Yuji; Hayashi, Yoshimitsu; Sato, Shuichi
2012-03-01
In badminton, knees opposite to the racket-hand side received anterior cruciate ligament (ACL) injuries during single-leg landing after overhead stroke. Most of them occurred in the backhand-side of the rear court. Comparing lower limb biomechanics during single-leg landing after overhead stroke between the forehand-side and backhand-side court may help explain the different injury rates depending on court position. The knee kinematics and kinetics during single-leg landing after overhead stroke following back-stepping were different between the forehand-side and backhand-side court. Controlled laboratory study. Hip, knee and ankle joint kinematic and knee kinetic data were collected for 17 right-handed female college badminton players using a 3-dimensional motion analysis system. Subjects performed single-left-legged landing after an overhead stroke following left and right back-stepping. The kinematic and kinetic data of the left lower extremities during landing were measured and compared between left and right back-steps. Hip flexion and abduction and knee valgus at the initial contact, hip and knee flexion and knee valgus at the maximum knee flexion and the maximum knee valgus moment were significantly larger for the left back-step than the right back-step (p<0.05). Significant differences in joint kinematics and kinetics of the lower extremity during single-leg landing after overhead stroke were observed between different back-step directions. Increased knee valgus angle and moment following back-stepping to the backhand-side might be related to the higher incidence of ACL injury during single-leg landing after overhead stroke.
Pollard, Christine D.; Sigward, Susan M.; Powers, Christopher M.
2009-01-01
Background It has been proposed that female athletes who limit knee and hip flexion during athletic tasks rely more on the passive restraints in the frontal plane to deceleration their body center of mass. This biomechanical pattern is thought to increase the risk for anterior cruciate ligament injury. To date, the relationship between sagittal plane kinematics and frontal plane knee motion and moments has not been explored. Methods Subjects consisted of fifty-eight female club soccer players (age range: 11 to 20 years) with no history of knee injury. Kinematics, ground reaction forces, and surface electromyography were collected while each subject performed a drop landing task. Subjects were divided into two groups based on combined sagittal plane knee and hip flexion angles during the deceleration phase of landing (high flexion and low flexion). Findings Subjects in the low flexion group demonstrated increased knee valgus angles (P = 0.02, effect size 0.27), increased knee adductor moments (P = 0.03, effect size 0.24), decreased energy absorption at the knee and hip (P = 0.02, effect size 0.25; and P< 0.001, effect size 0.59), and increased vastus lateralis EMG when compared to subjects in the high flexion group (P = 0.005, effect size 0.35). Interpretation Female athletes with limited sagittal plane motion during landing exhibit a biomechanical profile that may put these individuals at greater risk for anterior cruciate ligament injury. PMID:19913961
Differences in Lower Extremity and Trunk Kinematics between Single Leg Squat and Step Down Tasks
Lewis, Cara L.; Foch, Eric; Luko, Marc M.; Loverro, Kari L.; Khuu, Anne
2015-01-01
The single leg squat and single leg step down are two commonly used functional tasks to assess movement patterns. It is unknown how kinematics compare between these tasks. The purpose of this study was to identify kinematic differences in the lower extremity, pelvis and trunk between the single leg squat and the step down. Fourteen healthy individuals participated in this research and performed the functional tasks while kinematic data were collected for the trunk, pelvis, and lower extremities using a motion capture system. For the single leg squat task, the participant was instructed to squat as low as possible. For the step down task, the participant was instructed to stand on top of a box, slowly lower him/herself until the non-stance heel touched the ground, and return to standing. This was done from two different heights (16cm and 24cm). The kinematics were evaluated at peak knee flexion as well as at 60° of knee flexion. Pearson correlation coefficients (r) between the angles at those two time points were also calculated to better understand the relationship between each task. The tasks resulted in kinematics differences at the knee, hip, pelvis, and trunk at both time points. The single leg squat was performed with less hip adduction (p ≤ 0.003), but more hip external rotation and knee abduction (p ≤ 0.030), than the step down tasks at 60° of knee flexion. These differences were maintained at peak knee flexion except hip external rotation was only significant in the 24cm step down task (p ≤ 0.029). While there were multiple differences between the two step heights at peak knee flexion, the only difference at 60° of knee flexion was in trunk flexion (p < 0.001). Angles at the knee and hip had a moderate to excellent correlation (r = 0.51–0.98), but less consistently so at the pelvis and trunk (r = 0.21–0.96). The differences in movement patterns between the single leg squat and the step down should be considered when selecting a single leg task for evaluation or treatment. The high correlation of knee and hip angles between the three tasks indicates that similar information about knee and hip kinematics was gained from each of these tasks, while pelvis and trunk angles were less well predicted. PMID:25955321
Shono, Tomoki; Masumoto, Kenji; Fujishima, Kazutaka; Hotta, Noboru; Ogaki, Tetsuro; Adachi, Takahiro
2007-11-01
This study sought to determine the characteristics of gait patterns and muscle activity in the lower extremities of elderly women during underwater treadmill walking against water flow. Eight female subjects (61.4+/-3.9 y) performed underwater and land treadmill walking at varying exercise intensities and velocities. During underwater walking (water level at the xiphoid process) using the Flowmill, which has a treadmill at the base of a water flume, the simultaneous belt and water flow velocities were set to 20, 30 and 4 m.min(-1). Land walking velocities were set to 40, 60 and 80 m.min(-1). Oxygen uptake and heart rate were measured during both walking exercises. Maximum and minimum knee joint angles, and mean angular velocities of knee extension and knee flexion in the swing phase were calculated using two-dimensional motion analysis. Electromyograms were recorded using bipolar surface electrodes for five muscles: the tibialis anterior (TA), medial gastrocnemius (MG), vastus medialis (VM), rectus femoris (RF) and biceps femoris (BF). At the same exercise intensity level, cadence was almost half that on land. Step length did not differ significantly because velocity was halved. Compared to land walking, the maximum and minimum knee joint angles were significantly smaller and the mean angular velocity of knee extension was significantly lower. Knee extension in the swing phase was limited by water resistance. While the muscle activity levels of TA, VM and BF were almost the same as during land walking, those of MG and RF were lower. At the same velocity, exercise intensity was significantly higher than during land walking, cadence was significantly lower, and step length significantly larger. The knee joint showed significantly smaller maximum and minimum angles, and the mean angular velocity of knee flexion was significantly larger. The muscle activity levels of TA, VM, and BF increased significantly in comparison with land walking, although those of MG and RF did not significantly differ. Given our findings, it appears that buoyancy, lower cadence, and a moving floor influenced the muscle activity level of MG and RF at the same exercise intensity level and at the same velocity. These results show promise of becoming the basic data of choice for underwater walking exercise prescription.
Richards, Jim; Thewlis, Dominic; Selfe, James; Cunningham, Andrew; Hayes, Colin
2008-01-01
Context: Single-limb squats on a decline angle have been suggested as a rehabilitative intervention to target the knee extensors. Investigators, however, have presented very little empirical research in which they have documented the biomechanics of these exercises or have determined the optimum angle of decline used. Objective: To determine the involvement of the gastrocnemius and rectus femoris muscles and the external ankle and knee joint moments at 60° of knee flexion while performing a single-limb squat at different decline angles. Design: Participants acted as their own controls in a repeated-measures design. Patients or Other Participants: We recruited 10 participants who had no pain, injury, or neurologic disorder. Intervention(s): Participants performed single-limb squats at different decline angles. Main Outcome Measure(s): Angle-specific knee and ankle moments were calculated at 60° of knee flexion. Angle-specific electromyography (EMG) activity was calculated at 60° of knee flexion. Integrated EMG also was calculated to determine the level of muscle activity over the entire squat. Results: An increase was seen in the knee moments (P < .05) and integrated EMG in the rectus femoris (P < .001) as the decline angle increased. A decrease was seen in the ankle moments as the decline angle increased (P = .001), but EMG activity in the gastrocnemius increased between 16° and 24° (P = .018). Conclusions: As the decline angle increased, the knee extensor moment and EMG activity increased. As the decline angle increased, the ankle plantar-flexor moments decreased; however, an increase in the EMG activity was seen with the 24° decline angle compared with the 16° decline angle. This indicates that decline squats at an angle greater than 16° may not reduce passive calf tension, as was suggested previously, and may provide no mechanical advantage for the knee. PMID:18833310
Uğur, Levent
2017-12-01
Having a complicated anatomy, the knee joint has been further detailed and a new formation defined, the anterolateral ligament (ALL), in recent studies. While the importance of this ligament, which previously was associated with Segond fractures, was explained via clinical, radiologic and biomechanical studies, and basically, is thought to be a fixator structures for the tibia against internal rotation stress. Although in recent studies efficient surgical treatment was applied to patients who underwent anterior cruciate ligament (ACL) operation, some patients having a positive pivot test highlights the clinical importance of the ALL. The aim of this study is to evaluate reaction forces of different flexion angles on the tibia during internal rotation and anterior drawer tests on both the ALL and ACL, and to examine theimportance of this ligament in knee biomechanics by a finite element analysis method. In this study, normal anatomy knee joint was modelled using Computed Tomography images from lower extremity length in DICOM format. 0°, 15°,30°,45°,60°,75° and 90° angles of flexion were applied, respectively, to these models and reaction force vectors formed on both ligaments were examined separately and as total vector and size by applying internal rotation and anterior drawer forces on each model. Non-linear analysis was conducted using ANSYS (version 17) with the same limit conditions applied to all models. After all models were examined, in general when comparing reaction forces, those on the ACL were found to be higher. However, when vectoral directions were examined, forces on ALL increased with increased flexion ratio and internal rotation momentum. Beyond 30° flexion, the tensile force on the ALL is increased and compressive overload on the ACL occurs. The ALL plays an important role in stability, especially against internal rotation forces, and an increased knee joint flexion ratio increases the stability contribution ratio. In particular, at 30° and higher angles, ACL reflects an antagonist effect and contributes to knee joint stability for rotational and mediolateral transposition. Copyright © 2017 John Wiley & Sons, Ltd.
Usa, Hideyuki; Matsumura, Masashi; Ichikawa, Kazuna; Takei, Hitoshi
2017-01-01
This study attempted to develop a formula for predicting maximum muscle strength value for young, middle-aged, and elderly adults using theoretical Grade 3 muscle strength value (moment fair: M f )-the static muscular moment to support a limb segment against gravity-from the manual muscle test by Daniels et al. A total of 130 healthy Japanese individuals divided by age group performed isometric muscle contractions at maximum effort for various movements of hip joint flexion and extension and knee joint flexion and extension, and the accompanying resisting force was measured and maximum muscle strength value (moment max, M m ) was calculated. Body weight and limb segment length (thigh and lower leg length) were measured, and M f was calculated using anthropometric measures and theoretical calculation. There was a linear correlation between M f and M m in each of the four movement types in all groups, excepting knee flexion in elderly. However, the formula for predicting maximum muscle strength was not sufficiently compatible in middle-aged and elderly adults, suggesting that the formula obtained in this study is applicable in young adults only.
Matsumura, Masashi; Ichikawa, Kazuna; Takei, Hitoshi
2017-01-01
This study attempted to develop a formula for predicting maximum muscle strength value for young, middle-aged, and elderly adults using theoretical Grade 3 muscle strength value (moment fair: Mf)—the static muscular moment to support a limb segment against gravity—from the manual muscle test by Daniels et al. A total of 130 healthy Japanese individuals divided by age group performed isometric muscle contractions at maximum effort for various movements of hip joint flexion and extension and knee joint flexion and extension, and the accompanying resisting force was measured and maximum muscle strength value (moment max, Mm) was calculated. Body weight and limb segment length (thigh and lower leg length) were measured, and Mf was calculated using anthropometric measures and theoretical calculation. There was a linear correlation between Mf and Mm in each of the four movement types in all groups, excepting knee flexion in elderly. However, the formula for predicting maximum muscle strength was not sufficiently compatible in middle-aged and elderly adults, suggesting that the formula obtained in this study is applicable in young adults only. PMID:28133549
Mechanical behaviour of hamstring muscles in low-back pain patients and control subjects.
Tafazzoli, F; Lamontagne, M
1996-01-01
The purpose of this study was to measure and compare the passive elastic moment, the stiffness and the damping coefficient of the hip joint, as functions of the hip and knee joint angles in men with and without low-back pain. Two conventional tests, the straight-leg-raising test and the trunk forward flexion, were also performed and compared between these subjects. The passive elastic moment was measured using an isokinetic device in the passive mode. This device raised the lower limb from the horizontal position to the straight-leg-raising angle at a slow and constant angular velocity. A custom-made splint connected with the lever arm of the isokinetic device maintained the knee in extension and the ankle in the neutral position. The damping coefficient of the hip joint was measured for 0, 15, 45, 60, 75 and 90% of straight leg raising angle of each subject, using the suspension method based on small oscillation theory. To ensure that muscles were inactive during the passive hip moment tests, muscle activity was monitored with surface EMG. The stiffness was computed as the ratio of the change in passive elastic moment to the change in the hip angle. The passive elastic moment, the stiffness and the normalized trunk flexion were significantly different between the two groups respectively. There was, however, no difference between the two groups in the results of straight-leg-raise and damping coefficient of the hip. The passive elastic moment was a nonlinear function of the hip flexion angle and showed large intersubject differences, especially as the joint limit was approached. The damping coefficient was a polynomial function of the hip flexion angle. The measured variables were analysed using a discriminant function and it was shown that the two groups were clearly discriminable in a meaningful manner.
Knee Joint Kinematics and Kinetics During a Lateral False-Step Maneuver
Golden, Grace M.; Pavol, Michael J.; Hoffman, Mark A.
2009-01-01
Abstract Context: Cutting maneuvers have been implicated as a mechanism of noncontact anterior cruciate ligament (ACL) injuries in collegiate female basketball players. Objective: To investigate knee kinematics and kinetics during running when the width of a single step, relative to the path of travel, was manipulated, a lateral false-step maneuver. Design: Crossover design. Setting: University biomechanics laboratory. Patients or Other Participants: Thirteen female collegiate basketball athletes (age = 19.7 ± 1.1 years, height = 172.3 ± 8.3 cm, mass = 71.8 ± 8.7 kg). Intervention(s): Three conditions: normal straight-ahead running, lateral false step of width 20% of body height, and lateral false step of width 35% of body height. Main Outcome Measure(s): Peak angles and internal moments for knee flexion, extension, abduction, adduction, internal rotation, and external rotation. Results: Differences were noted among conditions in peak knee angles (flexion [P < .01], extension [P = .02], abduction [P < .01], and internal rotation [P < .01]) and peak internal knee moments (abduction [P < .01], adduction [P < .01], and internal rotation [P = .03]). The lateral false step of width 35% of body height was associated with larger peak flexion, abduction, and internal rotation angles and larger peak abduction, adduction, and internal rotation moments than normal running. Peak flexion and internal rotation angles were also larger for the lateral false step of width 20% of body height than for normal running, whereas peak extension angle was smaller. Peak internal rotation angle increased progressively with increasing step width. Conclusions: Performing a lateral false-step maneuver resulted in changes in knee kinematics and kinetics compared with normal running. The differences observed for lateral false steps were consistent with proposed mechanisms of ACL loading, suggesting that lateral false steps represent a hitherto neglected mechanism of noncontact ACL injury. PMID:19771289
Biomechanical study of anterior spinal instrumentation configurations
Cloutier, Luc P.; Grimard, Guy
2007-01-01
The biomechanical impact of the surgical instrumentation configuration for spine surgery is hard to evaluate by the surgeons in pre-operative situation. This study was performed to evaluate different configurations of the anterior instrumentation of the spine, with simulated post-operative conditions, to recommend configurations to the surgeons. Four biomechanical parameters of the anterior instrumentation with simulated post-operative conditions have been studied. They were the screw diameter (5.5–7.5 mm) and its angle (0°–22.5°), the bone grip of the screw (mono–bi cortical) and the amount of instrumented levels (5–8). Eight configurations were tested using an experimental plan with instrumented synthetic spinal models. A follower load was applied and the models were loaded in flexion, torsion and lateral bending. At 5 Nm, average final stiffness was greater in flexion (0.92 Nm/°) than in lateral bending (0.56 Nm/°) and than in torsion (0.26 Nm/°). The screw angle was the parameter influencing the most the final stiffness and the coupling behaviors. It has a significant effect (p ≤ 0.05) on increasing the final stiffness for a 22.5° screw angle in flexion and for a coronal screw angle (0°) in lateral bending. The bi-cortical bone grip of the screw significantly increased the initial stiffness in flexion and lateral bending. Mathematical models representing the behavior of an instrumented spinal model have been used to identify optimal instrumentation configurations. A variation of the angle of the screw from 22.5° to 0° gave a global final stiffness diminution of 13% and a global coupling diminution of 40%. The screw angle was the most important parameter affecting the stiffness and the coupling of the instrumented spine with simulated post-operative conditions. Information about the effect of four different biomechanical parameters will be helpful in preoperative situations to guide surgeons in their clinical choices. PMID:17205240
Arthrometric Evaluation of Stabilizing Effect of Knee Functional Bracing at Different Flexion Angles
Seyed Mohseni, Saeedeh; Moss, Farzam; Karimi, Hossein; Kamali, Mohammad
2009-01-01
Previous in-vivo investigations on the stabilizing efficacy of knee bracing for ACL reconstructed patients have been often limited to 20-30 degrees of knee flexion. In this study, the effectiveness of a uniaxial hinged functional brace to improve the knee stability was assessed at 30, 60 and 90 degrees of knee flexion. Arthrometry tests were conducted on 15 healthy subjects before and following wearing the brace and the tibial displacements were measured at up to 150 N anterior forces. Results indicated that functional bracing has a significant stabilizing effect throughout the range of knee flexion examined (p < 0.05). The rate of effectiveness, however, was not consistent across the flexion range, e.g., 50% at 30 degrees and only 4% at 90 degrees. It was suggested that accurate sizing and fitting as well as attention to correct hinge placement relative to the femoral condyles can limit brace migration and improve its effectiveness in mid and deep knee flexion. With using adaptive limb fittings, through flexible pads, and a polycentric joint a more significant improvement of the overall brace performance and efficacy might be obtained. Key points Functional bracing improves the knee joint stability mostly in extension posture. Unlike the non-braced condition, the least knee joint stability appears in mid and deep flexion angles when using a hinged brace. Accurate sizing and fitting and attention to correct hinge placement relative to the femoral condyles can limit brace migration and improve its effectiveness in mid and deep knee flexion. The overall brace performance and efficacy might be improved significantly using adaptive limb fittings through flexible pads and/or polycentric joints. PMID:24149533
Changes in the flexion relaxation response induced by lumbar muscle fatigue.
Descarreaux, Martin; Lafond, Danik; Jeffrey-Gauthier, Renaud; Centomo, Hugo; Cantin, Vincent
2008-01-24
The flexion relaxation phenomenon (FRP) is an interesting model to study the modulation of lumbar stability. Previous investigations have explored the effect of load, angular velocity and posture on this particular response. However, the influence of muscular fatigue on FRP parameters has not been thoroughly examined. The objective of the study is to identify the effect of erector spinae (ES) muscle fatigue and spine loading on myoelectric silence onset and cessation in healthy individuals during a flexion-extension task. Twenty healthy subjects participated in this study and performed blocks of 3 complete trunk flexions under 4 different experimental conditions: no fatigue/no load (1), no fatigue/load (2), fatigue/no load(3), and fatigue/load (4). Fatigue was induced according to the Sorenson protocol, and electromyographic (EMG) power spectral analysis confirmed that muscular fatigue was adequate in each subject. Trunk and pelvis angles and surface EMG of the ES L2 and L5 were recorded during a flexion-extension task. Trunk flexion angle corresponding to the onset and cessation of myoelectric silence was then compared across the different experimental conditions using 2 x 2 repeated-measures ANOVA. Onset of myoelectric silence during the flexion motion appeared earlier after the fatigue task. Additionally, the cessation of myoelectric silence was observed later during the extension after the fatigue task. Statistical analysis also yielded a main effect of load, indicating a persistence of ES myoelectric activity in flexion during the load condition. The results of this study suggest that the presence of fatigue of the ES muscles modifies the FRP. Superficial back muscle fatigue seems to induce a shift in load-sharing towards passive stabilizing structures. The loss of muscle contribution together with or without laxity in the viscoelastic tissues may have a substantial impact on post fatigue stability.
Magnetic resonance evaluation of the knee in children and adolescents with achondroplasia.
Akyol, Yakup; Averill, Lauren W; Atanda, Alfred; Kecskemethy, Heidi H; Bober, Michael B; Mackenzie, William G
2015-06-01
Achondroplasia is the most common form of skeletal dysplasia. Although the radiographic features are well described, MRI features of the knee in achondroplasia have not been reported. To describe common MRI characteristics of the knee joint in symptomatic children and adolescents with achondroplasia. We retrospectively evaluated 10 knee MRI examinations in 8 children and young adults (age range 11-20 years, mean 16.3 years) with achondroplasia. We measured modified Insall-Salvati index, knee flexion angle, anterior cruciate ligament (ACL)-Blumensaat line angle, ACL-tibial angle, posterior cruciate ligament (PCL) angle, intercondylar notch width index, and intercondylar notch depth index. We compared our findings with an age- and gender-matched control group of 20 children (age range 15-18 years; mean 16 years) with normal knee MRIs. All 10 knees in the achondroplasia group had discoid lateral meniscus; 8 meniscal tears were identified. Patella baja was present in half of the study cases. Greater knee flexion and increased ACL-Blumensaat line and PCL angles were seen in all achondroplasia knees. ACL-tibial angle was similar in the study and in the control group. Children with achondroplasia had deeper A-shape femoral notches that extended more anteriorly than those seen in the control group. MRI findings were confirmed in all seven knees with arthroscopic correlation. Discoid lateral meniscus, often with tear, is a consistent feature in knee MRIs of symptomatic children and adolescents with achondroplasia. Other findings include patella baja, knee flexion, deep A-shape intercondylar notch, increased ACL-Blumensaat line angle and taut PCL.
Gade, Venkata; Allen, Jerome; Cole, Jeffrey L; Barrance, Peter J
2016-07-01
To characterize the ability of patients with symptomatic knee osteoarthritis (OA) to perform a weight-bearing activity compatible with upright magnetic resonance imaging (MRI) scanning and how this ability is affected by knee pain symptoms and flexion angles. Cross-sectional observational study assessing effects of knee flexion angle, pain level, and study sequence on accuracy and duration of performing a task used in weight-bearing MRI evaluation. Visual feedback of knee position from an MRI compatible sensor was provided. Pain levels were self-reported on a standardized scale. Simulated MRI setup in a research laboratory. Convenience sample of individuals (N=14; 9 women, 5 men; mean, 69±14y) with symptomatic knee OA. Not applicable. Averaged absolute and signed angle error from target knee flexion for each minute of trial and duration tolerance (the duration that subjects maintained position within a prescribed error threshold). Absolute targeting error increased at longer trial durations (P<.001). Duration tolerance decreased with increasing pain (mean ± SE, no pain: 3min 19s±11s; severe pain: 1min 49s±23s; P=.008). Study sequence affected duration tolerance (first knee: 3min 5s±9.1s; second knee: 2min 19s±9.7s; P=.015). The study provided evidence that weight-bearing MRI evaluations based on imaging protocols in the range of 2 to 3 minutes are compatible with patients reporting mild to moderate knee OA-related pain. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
McGrath, Timothy; Fineman, Richard; Stirling, Leia
2018-06-08
Inertial measurement units (IMUs) have been demonstrated to reliably measure human joint angles—an essential quantity in the study of biomechanics. However, most previous literature proposed IMU-based joint angle measurement systems that required manual alignment or prescribed calibration motions. This paper presents a simple, physically-intuitive method for IMU-based measurement of the knee flexion/extension angle in gait without requiring alignment or discrete calibration, based on computationally-efficient and easy-to-implement Principle Component Analysis (PCA). The method is compared against an optical motion capture knee flexion/extension angle modeled through OpenSim. The method is evaluated using both measured and simulated IMU data in an observational study ( n = 15) with an absolute root-mean-square-error (RMSE) of 9.24∘ and a zero-mean RMSE of 3.49∘. Variation in error across subjects was found, made emergent by the larger subject population than previous literature considers. Finally, the paper presents an explanatory model of RMSE on IMU mounting location. The observational data suggest that RMSE of the method is a function of thigh IMU perturbation and axis estimation quality. However, the effect size for these parameters is small in comparison to potential gains from improved IMU orientation estimations. Results also highlight the need to set relevant datums from which to interpret joint angles for both truth references and estimated data.
A dynamic study of the anterior cruciate ligament of the knee using an open MRI.
Guenoun, Daphne; Vaccaro, Julien; Le Corroller, Thomas; Barral, Pierre-Antoine; Lagier, Aude; Pauly, Vanessa; Coquart, Benjamin; Coste, Joel; Champsaur, Pierre
2017-03-01
Recent anatomical and radiological studies of the anterior cruciate ligament (ACL) suggest the ACL length and orientation change during knee flexion, and an open MRI sequencing during knee flexion enables a dynamic ACL analysis. This study's goal is to describe a normal ACL using a 1T open MRI and, in particular, variations in length and insertion angles at different degrees of flexion. Twenty-one volunteers with clinically healthy knees received a dynamic MRI with their knees in hyperextension, neutral position, and flexed at 45° and 90° angles. For each position, two radiologists measured the ACL lengths and angles of the proximal insertion between the ACL's anterior edge and the roof of the inter-condylar notch. Additionally, we measured the ACL's and the tibial plateau's distal angle insertion between their anterior edges and then compared these with the nonparametric Wilcoxon test. The ACL had a significant extension between the 90° flexion and all other positions (hyperextension: 31.75 ± 2.5 mm, neutral position: 32.5 ± 2.6 mm, 45°: 35.6 ± 1.6 mm, 90°: 35.6 ± 1.6 mm). There was also a significant increase of the angle insertion between the proximal 90° flexion and all other positions, as well as between hyperextension and bending to 45° (hyperextension: 2.45° ± 3.7°, neutral: 13.4° ± 9.7°, 45°: 33 25 ± 9.3, 90: 51.85° ± 9.3°). Additionally, there is a significant increase in the distal angle insertion for all positions (hyperextension: 133.2° ± 5.4°, neutral position: 134.95° ± 4.4°, 45°: 138.35° ± 5.9°, 90°: 149.15° ± 8.6°). Our study is the first to exhibit that a dynamic MRI has a significant ACL extension in vivo during bending. This concept opens the way for further studies to improve the diagnosis of traumatic ACL injuries using a dynamic MRI.
Cammarata, Marco; Aubin, Carl-Éric; Wang, Xiaoyu; Mac-Thiong, Jean-Marc
2014-04-15
Biomechanical analysis of proximal junctional kyphosis (PJK) through computer simulations and sensitivity analysis. To gain biomechanical knowledge on the risk of PJK and find surgical solutions to reduce the risks. PJK is a pathological kyphotic deformity adjacent to the instrumentation. Clinical studies have documented its risk factors, but still little is known on how it is correlated with various individual instrumentation variables. Biomechanical spine models of 6 patients with adult scoliosis were developed, validated, and then used to perform 576 simulations, varying the proximal dissection procedure, the implant type at the upper instrumented vertebra, the sagittal rod curvature, and the proximal diameter of the proximal transition rods. Four biomechanical indices--the proximal junctional kyphotic angle, thoracic kyphosis, proximal flexion force, and proximal flexion moment--were assessed. The bilateral complete facetectomy, the posterior ligaments resection, and the combination of both increased the proximal junctional kyphotic angle (respectively, by 10%, 28% and 53%) and the proximal flexion force (4%, 12%, and 22%) and moment (16%, 44%, and 83%). Compared with pedicle screws at upper instrumented vertebra, proximal transverse process hooks reduced the 3 biomechanical indices by approximately 26%. The use of proximal transition rods with reduced proximal diameter from 5.5 mm to 4 mm decreased the proximal junctional kyphotic angle (by 6%) and the proximal flexion force (4%) and moment (8%). The increase of the sagittal rod curvature from 10° to 20°, 30°, and 40° increased the proximal junctional kyphotic angle (by 6%, 13%, and 19%) and the proximal flexion force (3%, 7%, and 10%) and moment (9%, 18%, and 27%). Preserving more posterior proximal intervertebral elements, the use of transition rods and transverse process hooks at upper instrumented vertebra, and reducing the global sagittal rod curvature each decreased the 4 biomechanical indices that may be involved in PJK. N/A.
Masuda, S; Furumatsu, T; Okazaki, Y; Kodama, Y; Hino, T; Kamatsuki, Y; Miyazawa, S; Ozaki, T
2018-04-10
A medial meniscus posterior root tear (MMPRT) is defined as an injury to the posterior meniscal insertion on the tibia. In MMPRT, the medial meniscus (MM) hoop function is damaged, and the MM undergoes a medial extrusion into the interior from the superior articular surface of the tibia. However, the details of MM position and movement during knee joint movement are unclear in MMPRT cases. The present study aims to evaluate MM position and movement via magnetic resonance imaging (MRI) examination of the MM posterior extrusion (MMPE) at knee flexion angles of 10° and 90°. We hypothesized that, during knee flexion, the MM will shift to the posterior and the posterior extrusion will increase compared to that when the knee is extended. Twenty-four patients were diagnosed with symptomatic MMPRT on open MRI examination. Preoperative MMPE, anteroposterior interval (API) of the MM, and MM medial extrusion (MMME) at knee flexion angles of 10° and 90° were measured. For patients with MMPRT, the MMPE increased from -4.77±1.43mm to 3.79±1.17mm (p<0.001) when the knee flexion angle increased from 10° to 90°. Further, flexing the knee from 10° to 90° decreased the API of the MM from 20.19±4.22mm to 16.41±5.14mm (p<0.001). MMME showed no significant change between knee flexion angles of 10° and 90°. This study demonstrated that, in cases of MMPRT, the MMPE clearly increases when the knee is flexed to 90°, while MMME does not change. Our results suggest that open MRI examination can be used to evaluate the dynamic position of the posterior MM by scanning the knee as it flexes to 90°. IV: retrospective cohort study. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Akınoğlu, Bihter; Kocahan, Tuğba
2017-02-01
The objective of this study was to reveal characteristics of muscle strength of upper extremities of wheelchair (WC) basketball players and to ensure more-specific training program preparation. Isokinetic muscle strength of 12 WC basketball players were assessed by ISOMED 2000 device. The assessment protocol was evaluated at 60°/sec velocity with 5 times repeated force and at 240°/sec with 15 times repeated force. This protocol was carried out individually for shoulder flexion-extension and wrist flexion-extension movements at the right and left extremities. The flexion/extension ratio was determined to be outside of the ratios accepted as normal for primarily shoulder joint and for wrist joint. The extension movement was stronger than flexion movement in the shoulders at both velocities and the flexion movement was stronger than ex-tension movement in the wrist. The repeat times where the peak torque occurred were 2-3 repeats at 60°/sec velocity during flexion and extension movements for the wrist and shoulders, and the peak torque occurred at an average of 5-6 repeats in the shoulders at 240°/sec velocity and it occurred at 3-4 repeats in the wrist. The angles where the peak torque of the shoulder flexion and extension occurred varied between 80°-115° at both velocities, and it varied between 5°-30° angles for the wrist. As this study revealed, determination of muscle strength characteristics of WC athletes and especially using objective isokinetic devices will guide the planning of the appropriate training and exercise programs and preventing sports injuries in long term.
Rupture of posterior cruciate ligament leads to radial displacement of the medial meniscus.
Zhang, Can; Deng, Zhenhan; Luo, Wei; Xiao, Wenfeng; Hu, Yihe; Liao, Zhan; Li, Kanghua; He, Hongbo
2017-07-11
To explore the association between the rupture of posterior cruciate ligament (PCL) and the radial displacement of medial meniscus under the conditions of different flexion and various axial loads. The radial displacement value of medial meniscus was measured for the specimens of normal adult knee joints, including 12 intact PCLs, 6 ruptures of the anterolateral bundle (ALB), 6 ruptures of the postmedial bundle (PMB), and 12 complete ruptures. The measurement was conducted at 0°, 30°, 60°, and 90° of knee flexion angles under 200 N, 400 N, 600 N, 800 N and 1000 N of axial loads respectively. The displacement values of medial meniscus of the ALB rupture group increased at 0° flexion under 800 N and 1000 N, and at 30°, 60° and 90° flexion under all loads in comparison with the PCL intact group. The displacement values of the PMB rupture group was higher at 0° and 90° flexion under all loads, and at 30° and 60° flexion under 800 N and 1000 N loads. The displacement of the PCL complete rupture group increased at all flexion angles under all loads. Either partial or complete rupture of the PCL can increase in the radial displacement of the medial meniscus, which may explain the degenerative changes that occuring in the medial meniscus due to PCL injury. Therefore, early reestablishment of the PCL is necessarily required in order to maintain stability of the knee joint after PCL injury.
Zhang, L; Butler, J; Nishida, T; Nuber, G; Huang, H; Rymer, W Z
1998-10-01
The direction of rotation (DOR) of individual elbow muscles, defined as the direction in which a muscle rotates the forearm relative to the upper arm in three-dimensional space, was studied in vivo as a function of elbow flexion and forearm rotation. Electrical stimulation was used to activate an individual muscle selectively, and the resultant flexion-extension, supination-pronation, and varus-valgus moments were used to determine the DOR. Furthermore, multi-axis moment-angle relationships of individual muscles were determined by stimulating the muscle at a constant submaximal level across different joint positions, which was assumed to result in a constant level of muscle activation. The muscles generate significant moments about axes other than flexion-extension, which is potentially important for actively controlling joint movement and maintaining stability about all axes. Both the muscle DOR and the multi axis moments vary with the joint position systematically. Variations of the DOR and moment-angle relationship across muscle twitches of different amplitudes in a subject were small, while there were considerable variations between subjects.
Biomechanical differences between experienced and inexperienced wheelchair users during sport.
Starrs, Paul; Chohan, Ambreen; Fewtrell, David; Richards, Jim; Selfe, James
2012-09-01
During functional wheelchair movement there are several types of stroke pattern that a manual wheelchair user (MWCU) can utilize in order to propel. To examine the biomechanical differences between disabled (WCU) and able-bodied (NWCU) children whilst taking part in functional activities at the Cheetahs Wheelchair Sports Club. A multiple measures cohort study. Eleven participants were divided into two groups; WCU (n = 7) and NWCU (n = 4). All subjects were asked to perform three functional tasks; 30-second agility test, 1-minute distance test and a 10-metre sprint test. Upper body kinematics were recoded using a XSens MVN BIOMECH motion capture suit. NWCU outperformed the WCU in all of the tasks, however, no significant differences between the group's results were found. Nevertheless, significant differences were found in the maximum shoulder flexion angle for both right and left with NWCU utilizing more flexion and near significant differences in the NWCU overall shoulder range for right and left. In order to increase function in young MWCU then more specific-based sessions should be implemented targeting the exploitation of large shoulder ranges during propulsion, consequently resulting in more efficient movement.
Impact of an implanted neuroprosthesis on community ambulation in incomplete SCI.
Lombardo, Lisa M; Kobetic, Rudolf; Pinault, Gilles; Foglyano, Kevin M; Bailey, Stephanie N; Selkirk, Stephen; Triolo, Ronald J
2018-03-01
Test the effect of a multi-joint control with implanted electrical stimulation on walking after spinal cord injury (SCI). Single subject research design with repeated measures. Hospital-based biomechanics laboratory and user assessment of community use. Female with C6 AIS C SCI 30 years post injury. Lower extremity muscle activation with an implanted pulse generator and gait training. Walking speed, maximum distance, oxygen consumption, upper extremity (UE) forces, kinematics and self-assessment of technology. Short distance walking speed at one-year follow up with or without stimulation was not significantly different from baseline. However, average walking speed was significantly faster (0.22 m/s) with stimulation over longer distances than volitional walking (0.12 m/s). In addition, there was a 413% increase in walking distance from 95 m volitionally to 488 m with stimulation while oxygen consumption and maximum upper extremity forces decreased by 22 and 16%, respectively. Stimulation also produced significant (P ≤ 0.001) improvements in peak hip and knee flexion, ankle angle at foot off and at mid-swing. An implanted neuroprosthesis enabled a subject with incomplete SCI to walk longer distances with improved hip and knee flexion and ankle dorsiflexion resulting in decreased oxygen consumption and UE support. Further research is required to determine the robustness, generalizability and functional implications of implanted neuroprostheses for community ambulation after incomplete SCI.
Influence of smartphone use styles on typing performance and biomechanical exposure.
Ko, Ping-Hsin; Hwang, Yaw-Huei; Liang, Huey-Wen
2016-06-01
Twenty-seven subjects completed 2-min typing tasks using four typing styles: right-hand holding/typing (S-thumb) and two-hand typing at three heights (B-low, B-mid and B-high). The styles had significant effects on typing performance, neck and elbow flexion and muscle activities of the right trapezius and several muscles of the right upper limb (p < 0.0001 by repeated-measure analysis of variance). The subjects typed the fewest words (error-adjusted characters per minute: 78) with the S-thumb style. S-thumb style resulted in similar flexion angles of the neck, elbow and wrist, but significantly increased muscle activities in all tested muscles compared with the B-mid style. Holding the phone high or low reduced the flexion angles of the neck and right elbow compared with the B-mid style, but the former styles increased the muscle activity of the right trapezius. Right-hand holding/typing was not a preferable posture due to high muscle activities and slow typing speed. Practitioner Summary: Right-hand holding/typing was not favoured, due to increased muscle activities and slower typing speed. Holding the phone high or low reduced the flexion angles of the neck and right elbow, but the former styles increased the muscle activity of the right trapezius compared with holding the phone at chest level.
Mechanics of jazz shoes and their effect on pointing in child dancers.
Fong Yan, Alycia; Smith, Richard; Vanwanseele, Benedicte; Hiller, Claire
2012-07-01
There has been little scientific investigation of the impact of dance shoes on foot motion or dance injuries. The pointed (plantar-flexed) foot is a fundamental component of both the technical requirements and the traditional aesthetic of ballet and jazz dancing. The aims of this study were to quantify the externally observed angle of plantar flexion in various jazz shoes compared with barefoot and to compare the sagittal plane bending stiffness of the various jazz shoes. Sixteen female recreational child dancers were recruited for 3D motion analysis of active plantar flexion. The jazz shoes tested were a split-sole jazz shoe, full-sole jazz shoe, and jazz sneaker. A shoe dynamometer measured the stiffness of the jazz shoes. The shoes had a significant effect on ankle plantar flexion. All jazz shoes significantly restricted the midfoot plantar flexion angle compared with the barefoot condition. The split-sole jazz shoe demonstrated the least restriction, whereas the full-sole jazz shoe the most midfoot restriction. A small restriction in metartarsophalangeal plantar flexion and a greater restriction at the midfoot joint were demonstrated when wearing stiff jazz shoes. These restrictions will decrease the aesthetic of the pointed foot, may encourage incorrect muscle activation, and have an impact on dance performance.
Miyamoto, N; Hirata, K; Kanehisa, H
2017-01-01
The purpose of this study was to examine whether the effects of hamstring stretching on the passive stiffness of each of the long head of the biceps femoris (BFl), semitendinosus (ST), and semimembranosus (SM) vary between passive knee extension and hip flexion stretching maneuvers. In 12 male subjects, before and after five sets of 90 s static stretching, passive lengthening measurements where knee or hip joint was passively rotated to the maximal range of motion (ROM) were performed. During the passive lengthening, shear modulus of each muscle was measured by ultrasound shear wave elastography. Both stretching maneuvers significantly increased maximal ROM and decreased passive torque at a given joint angle. Passive knee extension stretching maneuver significantly reduced shear modulus at a given knee joint angle in all of BFl, ST, and SM. In contrast, the stretching effect by passive hip flexion maneuver was significant only in ST and SM. The present findings indicate that the effects of hamstring stretching on individual passive muscles' stiffness vary between passive knee extension and hip flexion stretching maneuvers. In terms of reducing the muscle stiffness of BFl, stretching of the hamstring should be performed by passive knee extension rather than hip flexion. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Chen, CH; Li, JS; Hosseini, A; Gadikota, HR; Gill, TJ; Li, G
2011-01-01
Quadriceps avoidance and higher flexion strategy have been assumed as effects of ACL deficiency on knee joint function during gait. However, the effect of ACL deficiency on anteroposterior stability of the knee during gait is not well defined. In this study, ten patients with unilateral acute ACL ruptures and the contralateral side intact performed gait on a treadmill. Flexion angles and anteroposterior translation of the ACL injured and the intact controlateral knees were measured at every 10% of the stance phase of the gait (from heel strike to toe-off) using a combined MRI and dual fluoroscopic image system (DFIS). The data indicated that during the stance phase of the gait, the ACL-deficient knees showed higher flexion angles compared to the intact contralateral side, consistent with the assumption of a higher flexion gait strategy. However, the data also revealed that the ACL-deficient knees had higher anterior tibial translation compared to the intact contralateral side during the stance phase of the gait. The higher flexion gait strategy was not shown to correlate to a reduction of the anterior tibial translation in ACL deficient knees. These data may provide indications for conservative treatment or surgical reconstruction of the ACL injured knees in restoration of the knee kinematics during daily walking activities. PMID:22169387
Effect of torso flexion on the lumbar torso extensor muscle sagittal plane moment arms.
Jorgensen, Michael J; Marras, William S; Gupta, Purnendu; Waters, Thomas R
2003-01-01
Accurate anatomical inputs for biomechanical models are necessary for valid estimates of internal loading. The magnitude of the moment arm of the lumbar erector muscle group is known to vary as a function of such variables as gender. Anatomical evidence indicates that the moment arms decrease during torso flexion. However, moment arm estimates in biomechanical models that account for individual variability have been derived from imaging studies from supine postures. Quantify the sagittal plane moment arms of the lumbar erector muscle group as a function of torso flexion, and identify individual characteristics that are associated with the magnitude of the moment arms as a function of torso flexion. Utilization of a 0.3 Tesla Open magnetic resonance image (MRI) to image and quantify the moment arm of the right erector muscle group as a function of gender and torso flexion. Axial MRI images through and parallel to each of the lumbar intervertebral discs at four torso flexion angles were obtained from 12 male and 12 female subjects in a lateral recumbent posture. Multivariate analysis of variance was used to investigate the differences in the moment arms at different torso flexion angles, whereas hierarchical linear regression was used to investigate associations with individual anthropometric characteristics and spinal posture. The largest decrease in the lumbar erector muscle group moment arm from neutral to 45-degree flexion occurred at the L5-S1 level (9.7% and 8.9% for men and women, respectively). Measures of spinal curvature (L1-S1 lordosis), body mass and trunk characteristics (depth or circumference) were associated with the varying moment arm at most lumbar levels. The sagittal plane moment arms of the lumbar erector muscle mass decrease as the torso flexes forward. The change in moment arms as a function of torso flexion may have an impact on prediction of spinal loading in biomechanical models.
Comfort, Paul; Jones, Paul A; McMahon, John J; Newton, Robert
2015-01-01
The isometric midthigh pull (IMTP) has been used to monitor changes in force, maximum rate of force development (mRFD), and impulse, with performance in this task being associated with performance in athletic tasks. Numerous postures have been adopted in the literature, which may affect the kinetic variables during the task; therefore, the aim of this investigation was to determine whether different knee-joint angles (120°, 130°, 140°, and 150°) and hip-joint angles (125° and 145°), including the subjects preferred posture, affect force, mRFD, and impulse during the IMTP. Intraclass correlation coefficients demonstrated high within-session reliability (r ≥ .870, P < .001) for all kinetic variables determined in all postures, excluding impulse measures during the 130° knee-flexion, 125° hip-flexion posture, which showed a low to moderate reliability (r = .666-.739, P < .001), while between-sessions testing demonstrated high reliability (r > .819, P < .001) for all kinetic variables. There were no significant differences in peak force (P > .05, Cohen d = 0.037, power = .408), mRFD (P > .05, Cohen d = 0.037, power = .409), or impulse at 100 ms (P > .05, Cohen d = 0.056, power = .609), 200 ms (P > .05, Cohen d = 0.057, power = .624), or 300 ms (P > .05, Cohen d = 0.061, power = .656) across postures. Smallest detectable differences demonstrated that changes in performance of >1.3% in peak isometric force, >10.3% in mRFD, >5.3% in impulse at 100 ms, >4.4% in impulse at 200 ms, and >7.1% in impulse at 300 ms should be considered meaningful, irrespective of posture.
Kiriyama, Shinya; Sato, Haruhiko; Takahira, Naonobu
2009-01-01
Increased shank rotation during landing has been considered to be one of the factors for noncontact anterior cruciate ligament injuries in female athletes. There have been no known gender differences in rotational knee muscle strength, which is expected to inhibit exaggerated shank rotation. Women have less knee external rotator strength than do men. Lower external rotator strength is associated with increased internal shank rotation at the time of landing. Controlled laboratory study. One hundred sixty-nine healthy young subjects (81 female and 88 male; age, 17.0 +/- 1.0 years) volunteered to participate in this study. The subjects performed single-legged drop landings from a 20-cm height. Femoral and shank kinematics were measured using a 3D optoelectronic tracking system during the drop landings, and then the joint angles around the knee (flexion/extension, valgus/varus, and internal/external rotation) were calculated. The maximal isometric rotational muscle strength of the knee was measured at 30 degrees of knee flexion in a supine position using a dynamometer. The female subjects had significantly less external shank rotation strength than did the male subjects (P < .001). Female subjects also exhibited significantly greater peak shank internal rotation angles than did males during landing (P < .05). Moderate but significant association was found between the maximum shank external rotation strength and the peak shank internal rotation angle during landing (r = -0.322, P < .01). Female subjects tended to have poor shank external rotator strength. This may lead to large shank internal rotation movement during the single-legged drop landing. Improving strength training of the external rotator muscle may help decrease the rates of anterior cruciate ligament injury in female athletes.
Biomechanical consequences of a nonanatomic posterior medial meniscal root repair.
LaPrade, Christopher M; Foad, Abdullah; Smith, Sean D; Turnbull, Travis Lee; Dornan, Grant J; Engebretsen, Lars; Wijdicks, Coen A; LaPrade, Robert F
2015-04-01
Posterior medial meniscal root tears have been reported to extrude with the meniscus becoming adhered posteromedially along the posterior capsule. While anatomic repair has been reported to restore tibiofemoral contact mechanics, it is unknown whether nonanatomic positioning of a meniscal root repair to a posteromedial location would restore the loading profile of the knee joint. The purpose of this study was to compare the tibiofemoral contact mechanics of a nonanatomic posterior medial meniscal tear with that of the intact knee or anatomic repair. It was hypothesized that a nonanatomic root repair would not restore the tibiofemoral contact pressures and areas to that of the intact or anatomic repair state. Controlled laboratory study. Tibiofemoral contact mechanics were recorded in 6 male human cadaveric knee specimens (average age, 45.8 years) using pressure sensors. Each knee underwent 5 testing conditions for the posterior medial meniscal root: (1) intact knee; (2) root tear; (3) anatomic transtibial pull-out repair; (4) nonanatomic transtibial pull-out repair, placed 5 mm posteromedially along the edge of the articular cartilage; and (5) root tear concomitant with an ACL tear. Knees were loaded with a 1000-N axial compressive force at 4 flexion angles (0°, 30°, 60°, 90°), and contact area, mean contact pressure, and peak contact pressure were calculated. Contact area was significantly lower after nonanatomic repair than for the intact knee at all flexion angles (mean = 44% reduction) and significantly higher for anatomic versus nonanatomic repair at all flexion angles (mean = 27% increase). At 0° and 90°, and when averaged across flexion angles, the nonanatomic repair significantly increased mean contact pressures in comparison to the intact knee or anatomic repair. When averaged across flexion angles, the peak contact pressures after nonanatomic repair were significantly higher than the intact knee but not the anatomic repair. In contrast, when averaged across all flexion angles, the anatomic repair resulted in a 17% reduction in contact area and corresponding increases in mean and peak contact pressures of 13% and 26%, respectively, compared with the intact knee. For most testing conditions, the nonanatomic repair did not restore the contact area or mean contact pressures to that of the intact knee or anatomic repair. However, the anatomic repair produced near-intact contact area and resulted in relatively minimal increases in mean and peak contact pressures compared with the intact knee. Results emphasize the importance of ensuring an anatomic posterior medial meniscal root repair by releasing the extruded menisci from adhesions and the posteromedial capsule. Similar caution toward preventing displacement of the meniscal root repair construct should be emphasized. © 2015 The Author(s).
Sahin, Ismail; Iskender, Salim; Ozturk, Serdar; Balaban, Birol; Isik, Selcuk
2013-06-01
Breast hypertrophy is a significant health burden with symptoms of back and shoulder pain, intertrigo, and shoulder grooving from the bra straps. Women often rely on surgery to relieve these symptoms, and they are mostly satisfied with the results. The satisfaction from surgery usually is evaluated by subjective measures. Objective evidence testing of the surgical outcomes is lacking. In this study, 10 women with breast hypertrophy underwent reduction mammaplasty. Their surgical outcomes were evaluated using three-dimensional gait analysis before surgery and 2 months afterward. A statistical difference was sought between the kinematic data of the spine, hip, knee, and ankle joints. The average maximum anterior pelvic tilt angles decreased 41 %, and the average maximum spine anterior flexion angles decreased 30 %. The difference between the pre- and postoperative values was statistically significant. The analysis of the kinematic data showed no significant difference in the hip, knee, or ankle joint angles postoperatively. The outcomes of breast reduction surgery have been evaluated mostly by subjective means until recently. As an objective evidence for surgical gain in the current study, reduction mammaplasty resulted in the patients' improved body posture when walking. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Miyamoto, Wataru; Takao, Masato; Matsushita, Takashi
2013-06-01
To describe anterior fibrous bundle as an intra-articular residual disorder following ankle sprain. Between January 1998 and January 2009, we performed arthroscopy on 10 patients (7 males, 3 females; median age, 25 years; age range, 17-43 years) who had the uncommon problem of anterior ankle pain accompanied by restriction of plantar flexion following an ankle sprain. Pre-operative magnetic resonance imaging revealed osteochondral lesions (OCLs) of the talar dome in 3 patients, but no other findings that could explain restricted plantar flexion. All patients underwent arthroscopy for investigation and treatment of the cause of symptoms, and the 3 patients with OCL underwent additional arthroscopic drilling. Outcome was measured using the American Orthopedic Foot and Ankle Society Ankle-Hindfoot Scale (AOFAS) score, Visual Analogue Scale (VAS) for pain and active plantar flexion angle. In all patients, an anterior fibrous bundle was confirmed under arthroscopic investigation as the cause of symptoms and was resected arthroscopically. Median AOFAS and VAS scores improved significantly from 65 (range 61-82) and 70 (range 50-85) pre-operatively to 95 (range 84-100) and 4 (range 0-15) at final follow-up, respectively (p < 0.001). In addition, median active plantar flexion angle improved significantly from 40° (range 35-40) pre-operatively to 55° (range 45-55), (p < 0.01). An anterior fibrous bundle is one of the intra-articular residual disorders after ankle sprain that can cause restriction of plantar flexion.
The effect of dynamic stretching on hamstrings flexibility with respect to the spino-pelvic rhythm.
Hasebe, Kiyotaka; Okubo, Yu; Kaneoka, Koji; Takada, Kohei; Suzuki, Daisuke; Sairyo, Koichi
2016-01-01
To ascertain the dynamic stretch effects of flexibility of the hamstrings on lumbar spine and pelvic kinematics. Tight hamstrings are positively correlated with low back pain. However, it is unclear how flexibility of the hamstrings affects spino-pelvic rhythm. Twelve healthy men participated in the study. The straight leg raising (SLR) angle, finger floor distance (FFD), and spino-pelvic rhythm was measured before and after the 6-week stretching protocol. The forward bending task was divided into 4 phases. The paired t-test was used to determine significant differences before and after the FFD, SLR angle, lumbar motion, and pelvic motion, and spino-pelvic rhythm in each phase (p<0.05). After 6 weeks of stretching, significant improvements were seen in the FFD with maximum forward bending and in the SLR angle. Total pelvic rotation was also significantly increased in contrast to total lumbar flexion. A decreased spino-pelvic ratio was seen in the final phase. Dynamic stretching could change the spino-pelvic rhythm to a pelvis-dominant motion, indicating that flexible hamstrings are important for preventing low back pain.
The Relationship Between Maximum Isometric Strength and Ball Velocity in the Tennis Serve.
Baiget, Ernest; Corbi, Francisco; Fuentes, Juan Pedro; Fernández-Fernández, Jaime
2016-12-01
The aims of this study were to analyze the relationship between maximum isometric strength levels in different upper and lower limb joints and serve velocity in competitive tennis players as well as to develop a prediction model based on this information. Twelve male competitive tennis players (mean ± SD; age: 17.2 ± 1.0 years; body height: 180.1 ± 6.2 cm; body mass: 71.9 ± 5.6 kg) were tested using maximum isometric strength levels (i.e., wrist, elbow and shoulder flexion and extension; leg and back extension; shoulder external and internal rotation). Serve velocity was measured using a radar gun. Results showed a strong positive relationship between serve velocity and shoulder internal rotation (r = 0.67; p < 0.05). Low to moderate correlations were also found between serve velocity and wrist, elbow and shoulder flexion - extension, leg and back extension and shoulder external rotation (r = 0.36 - 0.53; p = 0.377 - 0.054). Bivariate and multivariate models for predicting serve velocity were developed, with shoulder flexion and internal rotation explaining 55% of the variance in serve velocity (r = 0.74; p < 0.001). The maximum isometric strength level in shoulder internal rotation was strongly related to serve velocity, and a large part of the variability in serve velocity was explained by the maximum isometric strength levels in shoulder internal rotation and shoulder flexion.
Valgus-varus motion of the knee in normal level walking and stair climbing.
Yu, B; Stuart, M J; Kienbacher, T; Growney, E S; An, K-N
1997-07-01
OBJECTIVE: The knee valgus-varus moment and the knee angles were compared between normal level walking and stair climbing. DESIGN: Ten healthy subjects were tested for ascent, descent, and level walking. BACKGROUND: An understanding of the normal valgus-varus motion of the knee during stair climbing is needed to apply biomechanical analysis of stair climbing as a evaluation tool for knee osteoarthritis patients. METHODS: A motion analysis system, three force plates, and a flight of stairs were used to collect kinematic and kinetic data. The knee angles and moments were calculated from the collected kinematic and kinetic data. RESULTS: The knee varus angle for the maximum knee valgus moments in stair climbing was significantly greater than that in level walking. The knee valgus moment was significantly correlated to ground reaction forces and knee valgus-varus angle during stair climbing and level walking. CONCLUSIONS: There is a coupling between the knee valgus-varus motion and flexion-extension motion. Ground reaction forces are the major contributors to the within-subject variation in the knee valgus-varus moment during stair climbing and level walking. The knee valgus-varus angle is a major contributor to the between-subject variation in the knee valgus moment during stair climbing and level walking.
Mohta, Medha; Agarwal, Deepti; Sethi, AK
2011-01-01
Needle-through-needle combined spinal–epidural (CSE) may cause significant delay in patient positioning resulting in settling down of spinal anaesthetic and unacceptably low block level. Bilateral hip flexion has been shown to extend the spinal block by flattening lumbar lordosis. However, patients with lower limb fractures cannot flex their injured limb. This study was conducted to find out if unilateral hip flexion could extend the level of spinal anaesthesia following a prolonged CSE technique. Fifty American Society of Anesthesiologists (ASA) I/II males with unilateral femur fracture were randomly allocated to Control or Flexion groups. Needle-through-needle CSE was performed in the sitting position at L2-3 interspace and 2.6 ml 0.5% hyperbaric bupivacaine injected intrathecally. Patients were made supine 4 min after the spinal injection or later if epidural placement took longer. The Control group patients (n=25) lay supine with legs straight, whereas the Flexion group patients (n=25) had their uninjured hip and knee flexed for 5 min. Levels of sensory and motor blocks and time to epidural drug requirement were recorded. There was no significant difference in sensory levels at different time-points; maximum sensory and motor blocks; times to achieve maximum blocks; and time to epidural drug requirement in two groups. However, four patients in the Control group in contrast to none in the Flexion group required epidural drug before start of surgery. Moreover, in the Control group four patients took longer than 30 min to achieve maximum sensory block. To conclude, unilateral hip flexion did not extend the spinal anaesthetic level; however, further studies are required to explore the potential benefits of this technique. PMID:21808396
Joint angles of the ankle, knee, and hip and loading conditions during split squats.
Schütz, Pascal; List, Renate; Zemp, Roland; Schellenberg, Florian; Taylor, William R; Lorenzetti, Silvio
2014-06-01
The aim of this study was to quantify how step length and the front tibia angle influence joint angles and loading conditions during the split squat exercise. Eleven subjects performed split squats with an additional load of 25% body weight applied using a barbell. Each subject's movements were recorded using a motion capture system, and the ground reaction force was measured under each foot. The joint angles and loading conditions were calculated using a cluster-based kinematic approach and inverse dynamics modeling respectively. Increases in the tibia angle resulted in a smaller range of motion (ROM) of the front knee and a larger ROM of the rear knee and hip. The external flexion moment in the front knee/hip and the external extension moment in the rear hip decreased as the tibia angle increased. The flexion moment in the rear knee increased as the tibia angle increased. The load distribution between the legs changed < 25% when split squat execution was varied. Our results describing the changes in joint angles and the resulting differences in the moments of the knee and hip will allow coaches and therapists to adapt the split squat exercise to the individual motion and load demands of athletes.
Effects of volitional spine stabilization on lifting task in recurrent low back pain population.
Haddas, Ram; Yang, James; Lieberman, Isador
2016-09-01
To examine the influence of volitional preemptive abdominal contraction (VPAC) and recurrent low back pain (rLBP) on trunk mechanics and neuromuscular control during a symmetric lifting task. A 2 × 2 crossover mixed design was used to examine the effects of VPAC and group. Thirty-seven healthy individuals and 32 rLBP individuals performed symmetric box lifting trials with and without VPAC to a 1-m height table 3D trunk, pelvis, and hip joint angle and electromyographic magnitude variables were obtained. Selected variables were analyzed using ANOVA. The VPAC induced differences in joint kinematics and muscle activity in rLBP and healthy subjects during symmetric lifting. A significant two-way interaction effect was observed for the semitendinosus activity. The VPAC increased external oblique muscle activity, reduced erector spinae and multifidus muscles activity, and induced greater trunk flexion angle, greater trunk side flexion angle, and greater hip flexion angle, and decreased pelvis obliquity angle in both groups. In addition, the rLBP subjects presented with a reduced external oblique and gluteus maximus muscle activity, greater erector spinae and multifidus muscles activity, and greater pelvis posterior tilt angle. Our results provide evidence that a VPAC strategy performed during symmetric lifting may potentially reduce exposure to biomechanical factors that can contribute to lumbar spine injury. The hamstring muscles may play an important role in achieving pelvic balance during the lifting maneuver. Incorporating the VPAC during dynamic stressful activities appears to help improve sensorimotor control and facilitate positioning of the lower extremities and the pelvis, while protecting the lumbar spine.
A study on muscle activity and ratio of the knee extensor depending on the types of squat exercise
Kang, Jeong-Il; Park, Joon-Su; Choi, Hyun; Jeong, Dae-Keun; Kwon, Hye-Min; Moon, Young-Jun
2017-01-01
[Purpose] For preventing the patellofemoral pain syndrome, this study aims to suggest a proper squat method, which presents selective muscle activity of Vastus Medialis Oblique and muscle activity ratios of Vastus Medialis Oblique/Vastus Lateralis by applying squat that is a representative weight bearing exercise method in various ways depending on the surface conditions and knee bending angles. [Subjects and Methods] An isometric squat that was accompanied by hip adduction, depending on the surface condition and the knee joint flexion angle, was performed by 24 healthy students. The muscle activity and the ratio of muscle activity were measured. [Results] In a comparison of muscle activity depending on the knee joint flexion angle on a weight-bearing surface, the vastus medialis oblique showed a significant difference at 15° and 60°. Meanwhile, in a comparison of the muscle activity ratio between the vastus medialis oblique and the vastus lateralis depending on the knee joint flexion angle on a weight-bearing surface, significant differences were observed at 15° and 60°. [Conclusion] An efficient squat exercise posture for preventing the patellofemoral pain syndrome is to increase the knee joint bending angle on a stable surface. But it would be efficient for patients with difficulties in bending the knee joint to keep a knee joint bending angle of 15 degrees or less on an unstable surface. It is considered that in future, diverse studies on selective Vastus Medialis Oblique strengthening exercise methods would be needed after applying them to patients with the patellofemoral pain syndrome. PMID:28210036
Higashihara, Ayako; Nagano, Yasuharu; Ono, Takashi; Fukubayashi, Toru
2018-06-01
This study aimed to investigate activation characteristics of the biceps femoris long head (BFlh) and semitendinosus (ST) muscles during the acceleration and maximum-speed phases of sprinting. Lower-extremity kinematics and electromyographic (EMG) activities of the BFlh and ST muscles were examined during the acceleration sprint and maximum-speed sprint in 13 male sprinters during an overground sprinting. Differences in hamstring activation during each divided phases and in the hip and knee joint angles and torques at each time point of the sprinting gait cycle were determined between two sprints. During the early stance of the acceleration sprint, the hip extension torque was significantly greater than during the maximum-speed sprint, and the relative EMG activation of the BFlh muscle was significantly higher than that of the ST muscle. During the late stance and terminal mid-swing of maximum-speed sprint, the knee was more extended and a higher knee flexion moment was observed compared to the acceleration sprint, and the ST muscle showed higher activation than that of the BFlh. These results indicate that the functional demands of the medial and lateral hamstring muscles differ between two different sprint performances.
Chiang, Hsin-Yu Ariel; Liu, Chien-Hsiou
2016-03-10
Tablet users may be at high risk of developing physical discomfort because of their usage behaviors and tablet design. Investigate the usage of tablets, variations in head and neck posture associated with different tablet tilt angles, and the association of tablet use with users' musculoskeletal discomfort. A survey of users' subjective perceptions conducted by questionnaire and measurements of users' postures by a 3D Motion analysis system was used to explore the effects of tablet use. The questionnaire results indicated that over half of the participants reported physical discomfort after using tablets, with the most prevalent discomfort in the neck and shoulders, and more intensity of discomfort for the back although only few participants experienced it. Chi-squared tests indicated that significantly more participants who tended to use tablet computers to play games reported having musculoskeletal discomfort after using a tablet. In addition, preferences for tablet tilt angles varied across tasks (reading and game playing). The results from the 3D motion analysis revealed that head and neck flexion angles were significantly reduced when the tablets were positioned at relatively steep tilt angles. Neck flexion angle was significantly higher in game playing. These data add information regarding to the usage of tablet and its associations with physical discomfort (significantly more participants who tended to use tablet computers to play games reported having musculoskeletal discomfort after using a tablet). Steep tilt angles (such as 60°) may cause tablet users to decrease their head and neck flexion angles, which could lead to a more neutral, effortless, and ergonomically correct posture. Maintaining proper neck posture during active activities such as game playing is recommended to avoid neck discomfort.
Brink, Yolandi; Louw, Quinette; Grimmer, Karen; Jordaan, Esmè
2015-12-01
There is evidence that consistent sitting for prolonged periods is associated with upper quadrant musculoskeletal pain (UQMP). It is unclear whether postural alignment is a significant risk factor. The aim of the prospective study (2010-2011) was to ascertain if three-dimensional sitting postural angles, measured in a real-life school computer classroom setting, predict seated-related UQMP. Asymptomatic Grade 10 high-school students, aged 15-17 years, undertaking Computer Application Technology, were eligible to participate. Using the 3D Posture Analysis Tool, sitting posture was measured while students used desk-top computers. Posture was reported as five upper quadrant angles (Head flexion, Neck flexion; Craniocervical angle, Trunk flexion and Head lateral bending). The Computer Usage Questionnaire measured seated-related UQMP and hours of computer use. The Beck Depression Inventory and the Multidimensional Anxiety Scale for Children assessed psychosocial factors. Sitting posture, computer use and psychosocial factors were measured at baseline. UQMP was measured at six months and one-year follow-up. 211, 190 and 153 students participated at baseline, six months and one-year follow-up respectively. 34.2% students complained of seated-related UQMP during the follow-up period. Increased head flexion (HF) predicted seated-related UQMP developing over time for a small group of students with pain scores greater than the 90th pain percentile, adjusted for age, gender, BMI, computer use and psychosocial factors (p = 0.003). The pain score increased 0.22 points per 1° increase in HF. Classroom ergonomics and postural hygiene should therefore focus on reducing large HF angles among computing adolescents. Copyright © 2015 Elsevier Ltd. All rights reserved.
Chain-loaded variable resistance warm-up improves free-weight maximal back squat performance.
Mina, Minas A; Blazevich, Anthony J; Giakas, Giannis; Seitz, Laurent B; Kay, Anthony D
2016-11-01
The acute influence of chain-loaded variable resistance exercise on subsequent free-weight one-repetition maximum (1-RM) back squat performance was examined in 16 recreationally active men. The participants performed either a free-weight resistance (FWR) or chain-loaded resistance (CLR) back squat warm-up at 85% 1-RM on two separate occasions. After a 5-min rest, the participants attempted a free-weight 1-RM back squat; if successful, subsequent 5% load additions were made until participants failed to complete the lift. During the 1-RM trials, 3D knee joint kinematics and knee extensor and flexor electromyograms (EMG) were recorded simultaneously. Significantly greater 1-RM (6.2 ± 5.0%; p < .01) and mean eccentric knee extensor EMG (32.2 ± 6.7%; p < .01) were found after the CLR warm-up compared to the FWR condition. However, no difference (p > .05) was found in concentric EMG, eccentric or concentric knee angular velocity, or peak knee flexion angle. Performing a CLR warm-up enhanced subsequent free-weight 1-RM performance without changes in knee flexion angle or eccentric and concentric knee angular velocities; thus a real 1-RM increase was achieved as the mechanics of the lift were not altered. These results are indicative of a potentiating effect of CLR in a warm-up, which may benefit athletes in tasks where high-level strength is required.
Haines, Tracie L; McBride, Jeffrey M; Triplett, N Travis; Skinner, Jared W; Fairbrother, Kimberly R; Kirby, Tyler J
2011-10-01
The purpose of this investigation was to compare valgus/varus knee angles during various jumps and lower body strength between males and females relative to body mass. Seventeen recreationally active females (age: 21.94 ± 2.59 years; height: 1.67 ± 0.05 m; mass: 64.42 ± 8.39 kg; percent body fat: 26.89 ± 6.26%; squat one-repetition maximum: 66.18 ± 19.47 kg; squat to body mass ratio: 1.03 ± 0.28) and 13 recreationally active males (age: 21.69 ± 1.65 years; height: 1.77 ± 0.07 m; mass: 72.39 ± 9.23 kg; percent body fat: 13.15 ± 5.18%; squat one-repetition maximum: 115.77 ± 30.40 kg; squat to body mass ratio: 1.59 ± 0.31) performed a one-repetition maximum in the squat and three of each of the following jumps: countermovement jump, 30 cm drop jump, 45 cm drop jump, and 60 cm drop jump. Knee angles were analysed using videography and body composition was analysed by dual-energy X-ray absorptiometry to allow for squat to body mass ratio and squat to fat free mass ratio to be calculated. Significant differences (P ≤ 0.05) were found between male and female one-repetition maximum, male and female squat to body mass ratio, and male and female squat to fat free mass ratio. Significant differences were found between male and female varus/valgus knee positions during maximum flexion of the right and left leg in the countermovement jump, drop jump from 30 cm, drop jump from 45 cm, and drop jump from 60 cm. Correlations between varus/valgus knee angles and squat to body mass ratio for all jumps displayed moderate, non-significant relationships (countermovement jump: r = 0.445; drop jump from 30 cm: r = 0.448; drop jump from 45 cm: r = 0.449; drop jump from 60 cm: r = 0.439). In conclusion, males and females have significantly different lower body strength and varus/valgus knee position when landing from jumps.
Multijoint kinetic chain analysis of knee extension during the soccer instep kick.
Naito, Kozo; Fukui, Yosuke; Maruyama, Takeo
2010-04-01
Although previous studies have shown that motion-dependent interactions between adjacent segments play an important role in producing knee extension during the soccer instep kick, detailed knowledge about the mechanisms underlying those interactions is lacking. The present study aimed to develop a 3-D dynamical model for the multijoint kinetic chain of the instep kick in order to quantify the contributions of the causal dynamical factors to the production of maximum angular velocity during knee extension. Nine collegiate soccer players volunteered to participate in the experiment and performed instep kicking movements while 3-D positional data and the ground reaction force were measured. A dynamical model was developed in the form of a linked system containing 8 segments and 18 joint rotations, and the knee extension/flexion motion was decomposed into causal factors related to muscular moment, gyroscopic moment, centrifugal force, Coriolis force, gravity, proximal endpoint linear acceleration, and external force-dependent terms. The rapid knee extension during instep kicking was found to result almost entirely from kicking leg centrifugal force, trunk rotation muscular moment, kicking leg Coriolis force, and trunk rotation gyroscopic-dependent components. Based on the finding that rapid knee extension during instep kicking stems from multiple dynamical factors, it is suggested that the multijoint kinetic chain analysis used in the present study is more useful for achieving a detailed understanding of the cause of rapid kicking leg movement than the previously used 2-D, two-segment kinetic chain model. The present results also indicated that the centrifugal effect due to the kicking hip flexion angular velocity contributed substantially to the generation of a rapid knee extension, suggesting that the adjustment between the kicking hip flexion angular velocity and the leg configuration (knee flexion angle) is more important for effective instep kicking than other joint kinematics.
Qian, Jing-guang; Rong, Ke; Qian, Zhenyun; Wen, Chen; Zhang, Songning
2015-01-01
[Purpose] The purpose of the study was to design and implement a multichannel dynamic functional electrical stimulation system and investigate acute effects of functional electrical stimulation of the tibialis anterior and rectus femoris on ankle and knee sagittal-plane kinematics and related muscle forces of hemiplegic gait. [Subjects and Methods] A multichannel dynamic electrical stimulation system was developed with 8-channel low frequency current generators. Eight male hemiplegic patients were trained for 4 weeks with electric stimulation of the tibia anterior and rectus femoris muscles during walking, which was coupled with active contraction. Kinematic data were collected, and muscle forces of the tibialis anterior and rectus femoris of the affected limbs were analyzed using a musculoskelatal modeling approach before and after training. A paired sample t-test was used to detect the differences between before and after training. [Results] The step length of the affected limb significantly increased after the stimulation was applied. The maximum dorsiflexion angle and maximum knee flexion angle of the affected limb were both increased significantly during stimulation. The maximum muscle forces of both the tibia anterior and rectus femoris increased significantly during stimulation compared with before functional electrical stimulation was applied. [Conclusion] This study established a functional electrical stimulation strategy based on hemiplegic gait analysis and musculoskeletal modeling. The multichannel functional electrical stimulation system successfully corrected foot drop and altered circumduction hemiplegic gait pattern. PMID:26696734
Bellmann, Malte; Schmalz, Thomas; Ludwigs, Eva; Blumentritt, Siegmar
2012-03-01
To investigate the immediate biomechanical effects after transition to a new microprocessor-controlled prosthetic knee joint. Intervention cross-over study with repeated measures. Only prosthetic knee joints were changed. Motion analysis laboratory. Men (N=11; mean age ± SD, 36.7±10.2y; Medicare functional classification level, 3-4) with unilateral transfemoral amputation. Two microprocessor-controlled prosthetic knee joints: C-Leg and a new prosthetic knee joint, Genium. Static prosthetic alignment, time-distance parameters, kinematic and kinetic parameters, and center of pressure. After a half-day training and an additional half-day accommodation, improved biomechanical outcomes were demonstrated by the Genium: lower ground reaction forces at weight acceptance during level walking at various velocities, increased swing phase flexion angles during walking on a ramp, and level walking with small steps. Maximum knee flexion angle during swing phase at various velocities was nearly equal for Genium. Step-over-step stair ascent with the Genium knee was more physiologic as demonstrated by a more equal load distribution between the prosthetic and contralateral sides and a more natural gait pattern. When descending stairs and ramps, knee flexion moments with the Genium tended to increase. During quiet stance on a decline, subjects using Genium accepted higher loading of the prosthetic side knee joint, thus reducing same side hip joint loading as well as postural sway. In comparision to the C-Leg, the Genium demonstrated immediate biomechanical advantages during various daily ambulatory activities, which may lead to an increase in range and diversity of activity of people with above-knee amputations. Results showed that use of the Genium facilitated more natural gait biomechanics and load distribution throughout the affected and sound musculoskeletal structure. This was observed during quiet stance on a decline, walking on level ground, and walking up and down ramps and stairs. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Jackson, Timothy J; Adamson, Gregory J; Peterson, Alexander; Patton, John; McGarry, Michelle H; Lee, Thay Q
2013-05-01
Many ulnar collateral ligament (UCL) reconstruction techniques have been created and biomechanically tested. Single-bundle reconstructions aim to re-create the important anterior bundle of the UCL. To date, no technique has utilized suspensory fixation on the ulnar and humeral sides to create a single-bundle reconstruction. The bisuspensory technique will restore valgus laxity to its native state, with comparable load-to-failure characteristics to the docking technique. Controlled laboratory study. Six matched pairs of fresh-frozen cadaveric elbows were randomized to undergo UCL reconstruction using either the docking technique or a novel single-bundle bisuspensory technique. Valgus laxity and rotation measurements were quantified using a MicroScribe 3DLX digitizer at various flexion angles for the native ligament, transected ligament, and 1 of the 2 tested reconstructed ligaments. Laxity testing was performed from maximum extension to 120° of flexion. Each reconstruction was then tested to failure, and the method of failure was recorded. Valgus laxity was restored to the intact state at all degrees of elbow flexion for both the docking and bisuspensory techniques. In load-to-failure testing, there was no significant difference with regard to stiffness, ultimate torque, ultimate torque angle, energy absorbed, and applied moment to reach 10° of valgus. Yield torques for the bisuspensory and docking reconstructions were 18.7 ± 7.8 N·m and 18.6 ± 4.4 N·m, respectively (P = .95). The ultimate torque for the bisuspensory technique measured 26.5 ± 9.2 N·m and for the docking technique measured 25.1 ± 7.1 N·m (P = .78). The bisuspensory fixation technique, a reproducible single-bundle reconstruction, was able to restore valgus laxity to the native state, with similar load-to-failure characteristics as the docking technique. This reconstruction technique could be considered in a clinical setting as a primary method of UCL reconstruction or as a backup fixation method should intraoperative complications occur.
Modification of the Grood and Suntay Joint Coordinate System equations for knee joint flexion.
Dabirrahmani, Danè; Hogg, Michael
2017-01-01
Since its introduction, the Grood and Suntay Joint Coordinate System (JCS) has been embraced by the International Society of Biomechanics (ISB) and been widely used for biomechanical reporting. There is, however, a limitation in its ability to provide correct flexion values over a wide range of clinically relevant flexion angles. This technical note addresses the limitation of the JCS equations and introduces a new set of equations to overcome this problem. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
A flexible wearable sensor for knee flexion assessment during gait.
Papi, Enrica; Bo, Yen Nee; McGregor, Alison H
2018-05-01
Gait analysis plays an important role in the diagnosis and management of patients with movement disorders but it is usually performed within a laboratory. Recently interest has shifted towards the possibility of conducting gait assessments in everyday environments thus facilitating long-term monitoring. This is possible by using wearable technologies rather than laboratory based equipment. This study aims to validate a novel wearable sensor system's ability to measure peak knee sagittal angles during gait. The proposed system comprises a flexible conductive polymer unit interfaced with a wireless acquisition node attached over the knee on a pair of leggings. Sixteen healthy volunteers participated to two gait assessments on separate occasions. Data was simultaneously collected from the novel sensor and a gold standard 10 camera motion capture system. The relationship between sensor signal and reference knee flexion angles was defined for each subject to allow the transformation of sensor voltage outputs to angular measures (degrees). The knee peak flexion angle from the sensor and reference system were compared by means of root mean square error (RMSE), absolute error, Bland-Altman plots and intra-class correlation coefficients (ICCs) to assess test-retest reliability. Comparisons of knee peak flexion angles calculated from the sensor and gold standard yielded an absolute error of 0.35(±2.9°) and RMSE of 1.2(±0.4)°. Good agreement was found between the two systems with the majority of data lying within the limits of agreement. The sensor demonstrated high test-retest reliability (ICCs>0.8). These results show the ability of the sensor to monitor knee peak sagittal angles with small margins of error and in agreement with the gold standard system. The sensor has potential to be used in clinical settings as a discreet, unobtrusive wearable device allowing for long-term gait analysis. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Suckut, Tell; Wages, Jensen; Lyles, Heather; Perrin, Benjamin
2017-01-01
Background Only a small amount of evidence exists linking hip abductor weakness to dynamic knee valgus during static and dynamic activities. The associations of hip extensor strength and hip kinematics during the landing of a single leg hop are not known. Purpose: To determine if relationships exist between hip extensor and abductor strength and hip kinematics in both involved and uninvolved limb during the landing phase of a single leg hop in recreational athletes post anterior cruciate ligament (ACL) reconstruction. The presence of similar associations was also evaluated in healthy recreational athletes. Study Design Controlled Laboratory Study; Cross-sectional Methods Twenty-four recreational college-aged athletes participated in the study (12 post ACL reconstruction; 12 healthy controls). Sagittal and frontal plane hip kinematic data were collected for five trials during the landing of a single leg hop. Hip extensor and abductor isometric force production was measured using a hand-held dynamometer and normalized to participants’ height and weight. Dependent and independent t-tests were used to analyze for any potential differences in hip strength or kinematics within and between groups, respectively. Pearson's r was used to demonstrate potential associations between hip strength and hip kinematics for both limbs in the ACL group and the right limb in the healthy control group. Results Independent t-tests revealed that participants post ACL reconstruction exhibited less hip extensor strength (0.18 N/Ht*BW vs. 0.25 N/Ht*BW, p=<.01) and landed with greater hip adduction (9.0 º vs. 0.8 º, p=<.01) compared with their healthy counterparts. In the ACL group, Pearson's r demonstrated a moderate and indirect relationship (r=-.62, p=.03) between hip extensor strength and maximum hip abduction/adduction angle in the involved limb. A moderate and direct relationship between hip abductor strength and maximum hip flexion angle was demonstrated in the both the involved (r=.62) and uninvolved limb (r=.65, p=.02). No significant associations were demonstrated between hip extensor or abductor strength and hip flexion and/or abduction/adduction angles in the healthy group. Conclusion The results suggest that hip extensors may play a role in minimizing hip adduction in the involved limb while the hip abductors seem to play a role in facilitating hip flexion during the landing phase of a single leg hop for both limbs following ACL reconstruction. Researchers and clinicians alike should consider the importance of the hip extensors in playing a more prominent role in contributing to frontal plane motion. Levels of Evidence Level 2a PMID:28593088
The Lower Extremity Biomechanics of Single- and Double-Leg Stop-Jump Tasks
2011-01-01
The anterior cruciate ligament (ACL) injury is a common occurrence in sports requiring stop-jump tasks. Single- and double-leg stop-jump techniques are frequently executed in sports. The higher risk of ACL injury in single-leg drop landing task compared to a double-leg drop landing task has been identified. However the injury bias between single- and double-leg landing techniques has not been investigated for stop-jump tasks. The purpose of this study was to determine the differences between single- and double-leg stop-jump tasks in knee kinetics that were influenced by the lower extremity kinematics during the landing phase. Ground reaction force, lower extremity kinematics, and knee kinetics data during the landing phase were obtained from 10 subjects performing single- and double-leg stop-jump tasks, using motion-capture system and force palates. Greater peak posterior and vertical ground reaction forces, and peak proximal tibia anterior and lateral shear forces (p < 0.05) during landing phase were observed of single-leg stop-jump. Single-leg stop-jump exhibited smaller hip and knee flexion angle, and knee flexion angular velocity at initial foot contact with the ground (p < 0.05). We found smaller peak hip and knee flexion angles (p < 0.05) during the landing phase of single-leg stop-jump. These results indicate that single-leg landing may have higher ACL injury risk than double-leg landing in stop-jump tasks that may be influenced by the lower extremity kinematics during the landing phase. Key points Non-contact ACL injuries are more likely to occur during the single-leg stop-jump task than during the double-leg stop-jump task. Single-leg stop-jump exhibited greater peak proximal tibia anterior and lateral shear forces, and peak posterior and vertical ground reaction forces during the landing phase than the double-leg stop-jump task. Single-leg stop-jump exhibited smaller hip flexion angle, knee flexion angle, and knee flexion angular velocity at initial foot contact with the ground. Single-leg stop-jump exhibited greater peak knee extension and valgus moment during the landing phase than the double-leg stop-jump task. Single-leg stop-jump extended the hip joint at initial foot contact with the ground. PMID:24149308
Chung, Kyu Sung; Choi, Choong Hyeok; Bae, Tae Soo; Ha, Jeong Ku; Jun, Dal Jae; Wang, Joon Ho; Kim, Jin Goo
2018-04-01
To compare tibiofemoral contact mechanics after fixation for medial meniscus posterior root radial tears (MMPRTs). Seven fresh knees from mature pigs were used. Each knee was tested under 5 conditions: normal knee, MMPRT, pullout fixation with simple sutures, fixation with modified Mason-Allen sutures, and all-inside fixation using Fastfix 360. The peak contact pressure and contact surface area were evaluated using a capacitive sensor positioned between the meniscus and tibial plateau, under a 1,000-N compression force, at different flexion angles (0°, 30°, 60°, and 90°). The peak contact pressure was significantly higher in MMPRTs than in normal knees (P = .018). Although the peak contact pressure decreased significantly after fixation at all flexion angles (P = .031), it never recovered to the values noted in the normal meniscus. No difference was observed among fixation groups (P = .054). The contact surface area was significantly lower in MMPRTs than in the normal meniscus (P = .018) and increased significantly after fixation at all flexion angles (P = .018) but did not recover to within normal limits. For all flexion angles except 60°, the contact surface area was significantly higher for fixation with Mason-Allen sutures than for fixation with simple sutures or all-inside fixation (P = .027). At 90° of flexion, the contact surface area was significantly better for fixation with simple sutures than for all-inside fixation (P = .031). The peak contact pressure and contact surface area improved significantly after fixation, regardless of the fixation method, but did not recover to the levels noted in the normal meniscus after any type of fixation. Among the fixation methods evaluated in this time 0 study, fixation using modified Mason-Allen sutures provided a superior contact surface area compared with that noted after fixation using simple sutures or all-inside fixation, except at 60° of flexion. However, this study had insufficient power to accurately detect the differences between the outcomes of various fixation methods. Our results in a porcine model suggest that fixation can restore tibiofemoral contact mechanics in MMPRT and that fixation with a locking mechanism leads to superior biomechanical properties. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Combined Effects of Fatigue and Surface Instability on Jump Biomechanics in Elite Athletes.
Prieske, Olaf; Demps, Marie; Lesinski, Melanie; Granacher, Urs
2017-09-01
The present study aimed to examine the effects of fatigue and surface instability on kinetic and kinematic jump performance measures. Ten female and 10 male elite volleyball players (18±2 years) performed repetitive vertical double-leg box jumps until failure. Pre and post fatigue, jump height/performance index, ground reaction force and knee flexion/valgus angles were assessed during drop and countermovement jumps on stable and unstable surfaces. Fatigue, surface condition, and sex resulted in significantly lower drop jump performance and ground reaction force (p≤0.031, 1.1≤d≤3.5). Additionally, drop jump knee flexion angles were significantly lower following fatigue (p=0.006, d=1.5). A significant fatigue×surface×sex interaction (p=0.020, d=1.2) revealed fatigue-related decrements in drop jump peak knee flexion angles under unstable conditions and in men only. Knee valgus angles were higher on unstable compared to stable surfaces during drop jumps and in females compared to males during drop and countermovement jumps (p≤0.054, 1.0≤d≤1.1). Significant surface×sex interactions during countermovement jumps (p=0.002, d=1.9) indicated that knee valgus angles at onset of ground contact were significantly lower on unstable compared to stable surfaces in males but higher in females. Our findings revealed that fatigue and surface instability resulted in sex-specific knee motion strategies during jumping in elite volleyball players. © Georg Thieme Verlag KG Stuttgart · New York.
Changes of contact pressure and area in patellofemoral joint after different meniscectomies.
Bai, Bo; Shun, Hui; Yin, Zhi Xun; Liao, Zhuang-Wen; Chen, Ni
2012-05-01
We investigated the contact pressure and area of the patellofemoral joint both before and after different meniscectomies to provide a biomechanical basis for selecting meniscectomy and its clinical application for meniscus injuries. Six fresh cadaveric knees were used in the study. Using Staubli robots and an ultra-low-min-type pressure-sensitive tablet, changes in contact area and stress in the patellofemoral joint were measured at various flexion angles following different parts and degrees of meniscectomy. The patellofemoral contact area enlarged with the increase of knee flexion angle. From the values obtained from contact areas and average contact pressure of the patellofemoral joint, we found no significant difference between partial meniscectomy and intact knees, but a significant difference was found between total meniscectomy and intact knees. The contact area after lateral meniscectomy was statistically less than that of intact knees. The mean patellofemoral contact pressure after lateral meniscectomy was larger than in intact knees at each angle of flexion. No significant difference in contact area was observed between intact knees and medial meniscectomy. The average patellofemoral contact pressure after medial meniscectomy was larger than in intact knees from 0° ~ 30° of knee flexion, and no significant differences were found between intact knees and medial meniscectomy while knee bending from 60° to 90°. Different meniscectomies result in high contact pressure or disordered distribution of contact pressure, which may be the cause of postoperative patellofemoral degenerative arthrosis.
NASA Technical Reports Server (NTRS)
Bekdash, Omar; Norcross, Jason; McFarland, Shane
2015-01-01
Mobility tracking of human subjects while conducting suited operations still remains focused on the external movement of the suit and little is known about the human movement within it. For this study, accelerometers and bend sensitive resistors were integrated into a custom carrier glove to quantify range of motion and dexterity from within the pressurized glove environment as a first stage feasibility study of sensor hardware, integration, and reporting capabilities. Sensors were also placed on the exterior of the pressurized glove to determine if it was possible to compare a glove joint angle to the anatomical joint angle of the subject during tasks. Quantifying human movement within the suit was feasible, with accelerometers clearly detecting movements in the wrist and reporting expected joint angles at maximum flexion or extension postures with repeatability of plus or minus 5 degrees between trials. Bend sensors placed on the proximal interphalangeal and distal interphalangeal joints performed less well. It was not possible to accurately determine the actual joint angle using these bend sensors, but these sensors could be used to determine when the joint was flexed to its maximum and provide a general range of mobility needed to complete a task. Further work includes additional testing with accelerometers and the possible inclusion of hardware such as magnetometers or gyroscopes to more precisely locate the joint in 3D space. We hope to eventually expand beyond the hand and glove and develop a more comprehensive suit sensor suite to characterize motion across more joints (knee, elbow, shoulder, etc.) and fully monitor the human body operating within the suit environment.
Yoshihara, Yasushi; Arai, Yuji; Nakagawa, Shuji; Inoue, Hiroaki; Ueshima, Keiichiro; Fujiwara, Hiroyoshi; Oda, Ryo; Taniguchi, Daigo; Kubo, Toshikazu
2016-08-01
Favourable long-term results after total knee arthroplasty (TKA) require appropriate soft tissue balance. However, the relationships between long-term results after TKA surgery and mediolateral laxities at extension and at 90° flexion remain unknown. This study therefore quantitatively assessed ligament balance at extension and at 90° knee flexion at least 10 years after primary TKA, as well as clarifying the relationships between long-term outcomes and mediolateral laxities. This study included 49 knees (19 CR type and 30 PS type) of 33 patients followed up for at least 10 years after TKA at our hospital. Plain radiographs were obtained with about 150 N of varus or valgus stress using a Telos arthrometer at extension. At 90° flexion, epicondylar views were obtained under a 1.5-kg load and with about 10 kg of varus or valgus stress. Lateral laxity of about 5° was observed in both extension and flexion, with total laxities of varus and valgus stress each less than 10°. Postoperative clinical outcomes were good, with significant improvements in extension angle, femorotibial angle, and KSS, and no loosening in any knee. Good long-term results of TKA can be obtained with a lateral laxity of about 5°, equivalent to that of healthy knees. III.
Chen, Chih-Hui; Li, Jing-Sheng; Hosseini, Ali; Gadikota, Hemanth R; Gill, Thomas J; Li, Guoan
2012-03-01
Quadriceps avoidance and higher flexion strategies have been assumed as effects of ACL deficiency on knee joint function during gait. However, the effect of ACL deficiency on anteroposterior stability of the knee during gait is not well defined. In this study, 10 patients with unilateral acute ACL ruptures and the contralateral side intact performed gait on a treadmill. Flexion angles and anteroposterior translation of the ACL injured and the intact controlateral knees were measured at every 10% of the stance phase of the gait (from heel strike to toe-off) using a combined MRI and dual fluoroscopic imaging system (DFIS). The data indicated that during the stance phase of the gait, the ACL-deficient knees showed higher flexion angles compared to the intact contralateral side, consistent with the assumption of a higher flexion gait strategy. However, the data also revealed that the ACL-deficient knees had higher anterior tibial translation compared to the intact contralateral side during the stance phase of the gait. The higher flexion gait strategy was not shown to correlate to a reduction of the anterior tibial translation in ACL deficient knees. These data may provide indications for conservative treatment or surgical reconstruction of the ACL injured knees in restoration of the knee kinematics during daily walking activities. Copyright © 2011 Elsevier B.V. All rights reserved.
Test-retest reliability of 3D ultrasound measurements of the thoracic spine.
Fölsch, Christian; Schlögel, Stefanie; Lakemeier, Stefan; Wolf, Udo; Timmesfeld, Nina; Skwara, Adrian
2012-05-01
To explore the reliability of the Zebris CMS 20 ultrasound analysis system with pointer application for measuring end-range flexion, end-range extension, and neutral kyphosis angle of the thoracic spine. The study was performed within the School of Physiotherapy in cooperation with the Orthopedic Department at a University Hospital. The thoracic spines of 28 healthy subjects were measured. Measurements for neutral kyphosis angle, end-range flexion, and end-range extension were taken once at each time point. The bone landmarks were palpated by one examiner and marked with a pointer containing 2 transmitters using a frequency of 40 kHz. A third transmitter was fixed to the pelvis, and 3 microphones were used as receiver. The real angle was calculated by the software. Bland-Altman plots with 95% limits of agreement, intraclass correlations (ICC), standard deviations of mean measurements, and standard error of measurements were used for statistical analyses. The test-retest reliability in this study was measured within a 24-hour interval. Statistical parameters were used to judge reliability. The mean kyphosis angle was 44.8° with a standard deviation of 17.3° at the first measurement and a mean of 45.8° with a standard deviation of 16.2° the following day. The ICC was high at 0.95 for the neutral kyphosis angle, and the Bland-Altman 95% limits of agreement were within clinical acceptable margins. The ICC was 0.71 for end-range flexion and 0.34 for end-range extension, whereas the Bland-Altman 95% limits of agreement were wider than with the static measurement of kyphosis. Compared with static measurements, the analysis of motion with 3-dimensional ultrasound showed an increased standard deviation for test-retest measurements. The test-retest reliability of ultrasound measuring of the neutral kyphosis angle of the thoracic spine was demonstrated within 24 hours. Bland-Altman 95% limits of agreement and the standard deviation of differences did not appear to be clinically acceptable for measuring flexion and extension. Copyright © 2012 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Ko, Seung-Nam
2017-01-01
Posterior cruciate ligament (PCL) reconstruction for patients with PCL insufficiency has been associated with postoperative improvements in proprioceptive function due to mechanoreceptor regeneration. However, it is unclear whether reconstructed PCL or contralateral normal knees have better proprioceptive function outcomes. This meta-analysis was designed to compare the proprioceptive function of reconstructed PCL or contralateral normal knees in patients with PCL insufficiency. All studies that compared proprioceptive function, as assessed with threshold to detect passive movement (TTDPM) or joint position sense (JPS) in PCL reconstructed or contralateral normal knees were included. JPS was calculated by reproducing passive positioning (RPP). Five studies met the inclusion/exclusion criteria for the meta-analysis. The proprioceptive function, defined as TTDPM (95% CI: 0.25 to 0.51°; P<0.00001) and RPP (95% CI: 0.19 to 0.45°; P<0.00001), was significantly different between the reconstructed PCL and contralateral normal knees. The mean difference in angle of error between the reconstructed PCL and contralateral normal knees was 0.06° greater in TTDPM than by RPP. In addition, results from subgroup analyses, based on the starting angles and the moving directions of the knee, that evaluated TTDPM at 15° flexion to 45° extension, TTDPM at 45° flexion to 110° flexion, RPP in flexion, and RPP in extension demonstrated that mean angles of error were significantly greater, by 0.38° (P = 0.0001), 0.36° (P = 0.02), 0.36° (P<0.00001), and 0.23° (P = 0.04), respectively, in reconstructed PCL than in contralateral normal knees. The proprioceptive function of PCL reconstructed knees was decreased, compared with contralateral normal knees, as determined by both TTDPM and RPP. In addition, the amount of loss of proprioception was greater in TTDPM than in RPP, even with minute differences. Results from subgroup analysis, that evaluated the mean angles of error in moving directions through RPP, suggested that the moving direction of flexion has a significantly greater mean for angles of error than the moving direction of extension. Although the level of differences between various parameters were statistically significant, further studies are needed to determine whether the small differences (>1°) of the loss of proprioception are clinically relevant. PMID:28922423
Charlton, Jesse M; Hammond, Connor A; Cochrane, Christopher K; Hatfield, Gillian L; Hunt, Michael A
2017-06-01
Barbell back squats are a popular exercise for developing lower extremity strength and power. However, this exercise has potential injury risks, particularly to the lumbar spine, pelvis, and hip joint. Previous literature suggests heel wedges as a means of favorably adjusting trunk and pelvis kinematics with the intention of reducing such injury risks. Yet no direct biomechanical research exists to support these recommendations. Therefore, the purpose of this study was to examine the effects of heel wedges compared with barefoot on minimally loaded barbell back squats. Fourteen trained male participants performed a barbell back squat in bare feet or with their feet raised bilaterally with a 2.5-cm wooden block while 3-dimensional kinematics, kinetics, and electromyograms were collected. The heel wedge condition elicited significantly less forward trunk flexion angles at peak knee flexion, and peak external hip joint moments (p ≤ 0.05) compared with barefoot conditions. However, no significant differences were observed between conditions for trunk and pelvis angle differences at peak knee flexion (p > 0.05). Lastly, no peak or root mean square differences in muscle activity were elicited between conditions (p > 0.05). Our results lend support for the suggestions provided in literature aimed at using heel wedges as a means of reducing excessive forward trunk flexion. However, the maintenance of a neutral spine, another important safety factor, is not affected by the use of heel wedges. Therefore, heel wedges may be a viable modification for reduction of excessive forward trunk flexion but not for reduction in relative trunk-pelvis flexion during barbell back squats.
The Relationship Between Maximum Isometric Strength and Ball Velocity in the Tennis Serve
Corbi, Francisco; Fuentes, Juan Pedro; Fernández-Fernández, Jaime
2016-01-01
Abstract The aims of this study were to analyze the relationship between maximum isometric strength levels in different upper and lower limb joints and serve velocity in competitive tennis players as well as to develop a prediction model based on this information. Twelve male competitive tennis players (mean ± SD; age: 17.2 ± 1.0 years; body height: 180.1 ± 6.2 cm; body mass: 71.9 ± 5.6 kg) were tested using maximum isometric strength levels (i.e., wrist, elbow and shoulder flexion and extension; leg and back extension; shoulder external and internal rotation). Serve velocity was measured using a radar gun. Results showed a strong positive relationship between serve velocity and shoulder internal rotation (r = 0.67; p < 0.05). Low to moderate correlations were also found between serve velocity and wrist, elbow and shoulder flexion – extension, leg and back extension and shoulder external rotation (r = 0.36 – 0.53; p = 0.377 – 0.054). Bivariate and multivariate models for predicting serve velocity were developed, with shoulder flexion and internal rotation explaining 55% of the variance in serve velocity (r = 0.74; p < 0.001). The maximum isometric strength level in shoulder internal rotation was strongly related to serve velocity, and a large part of the variability in serve velocity was explained by the maximum isometric strength levels in shoulder internal rotation and shoulder flexion. PMID:28149411
Effects of grip force on median nerve deformation at different wrist angles
Nakashima, Hiroki; Muraki, Satoshi
2016-01-01
The present study investigated the effects of grip on changes in the median nerve cross-sectional area (MNCSA) and median nerve diameter in the radial-ulnar direction (D1) and dorsal-palmar direction (D2) at three wrist angles. Twenty-nine healthy participants (19 men [mean age, 24.2 ± 1.6 years]; 10 women [mean age, 24.0 ± 1.6 years]) were recruited. The median nerve was examined at the proximal carpal tunnel region in three grip conditions, namely finger relaxation, unclenched fist, and clenched fist. Ultrasound examinations were performed in the neutral wrist position (0°), at 30°wrist flexion, and at 30°wrist extension for both wrists. The grip condition and wrist angle showed significant main effects (p < 0.01) on the changes in the MNCSA, D1, and D2. Furthermore, significant interactions (p < 0.01) were found between the grip condition and wrist angle for the MNCSA, D1, and D2. In the neutral wrist position (0°), significant reductions in the MNCSA, D1, and D2 were observed when finger relaxation changed to unclenched fist and clenched fist conditions. Clenched fist condition caused the highest deformations in the median nerve measurements (MNCSA, approximately −25%; D1, −13%; D2, −12%). The MNCSA was significantly lower at 30°wrist flexion and 30°wrist extension than in the neutral wrist position (0°) at unclenched fist and clenched fist conditions. Notably, clenched fist condition at 30°wrist flexion showed the highest reduction of the MNCSA (−29%). In addition, 30°wrist flexion resulted in a lower D1 at clenched fist condition. In contrast, 30°wrist extension resulted in a lower D2 at both unclenched fist and clenched fist conditions. Our results suggest that unclenched fist and clenched fist conditions cause reductions in the MNCSA, D1, and D2. More importantly, unclenched fist and clenched fist conditions at 30°wrist flexion and 30°wrist extension can lead to further deformation of the median nerve. PMID:27688983
Is midsole thickness a key parameter for the running pattern?
Chambon, Nicolas; Delattre, Nicolas; Guéguen, Nils; Berton, Eric; Rao, Guillaume
2014-01-01
Many studies have highlighted differences in foot strike pattern comparing habitually shod runners who ran barefoot and with running shoes. Barefoot running results in a flatter foot landing and in a decreased vertical ground reaction force compared to shod running. The aim of this study was to investigate one possible parameter influencing running pattern: the midsole thickness. Fifteen participants ran overground at 3.3 ms(-1) barefoot and with five shoes of different midsole thickness (0 mm, 2 mm, 4 mm, 8 mm, 16 mm) with no difference of height between rearfoot and forefoot. Impact magnitude was evaluated using transient peak of vertical ground reaction force, loading rate, tibial acceleration peak and rate. Hip, knee and ankle flexion angles were computed at touch-down and during stance phase (range of motion and maximum values). External net joint moments and stiffness for hip, knee and ankle joints were also observed as well as global leg stiffness. No significant effect of midsole thickness was observed on ground reaction force and tibial acceleration. However, the contact time increased with midsole thickness. Barefoot running compared to shod running induced ankle in plantar flexion at touch-down, higher ankle dorsiflexion and lower knee flexion during stance phase. These adjustments are suspected to explain the absence of difference on ground reaction force and tibial acceleration. This study showed that the presence of very thin footwear upper and sole was sufficient to significantly influence the running pattern. Copyright © 2014 Elsevier B.V. All rights reserved.
2013-01-01
Background In spastic cerebral palsy (SCP), a limited range of motion of the foot (ROM), limits gait and other activities. Assessment of this limitation of ROM and knowledge of active mechanisms is of crucial importance for clinical treatment. Methods For a comparison between spastic cerebral palsy (SCP) children and typically developing children (TD), medial gastrocnemius muscle-tendon complex length was assessed using 3-D ultrasound imaging techniques, while exerting externally standardized moments via a hand-held dynamometer. Exemplary X-ray imaging of ankle and foot was used to confirm possible TD-SCP differences in foot deformation. Results SCP and TD did not differ in normalized level of excitation (EMG) of muscles studied. For given moments exerted in SCP, foot plate angles were all more towards plantar flexion than in TD. However, foot plate angle proved to be an invalid estimator of talocrural joint angle, since at equal foot plate angles, GM muscle-tendon complex was shorter in SCP (corresponding to an equivalent of 1 cm). A substantial difference remained even after normalizing for individual differences in tibia length. X-ray imaging of ankle and foot of one SCP child and two typically developed adults, confirmed that in SCP that of total footplate angle changes (0-4 Nm: 15°), the contribution of foot deformation to changes in foot plate angle (8) were as big as the contribution of dorsal flexion at the talocrural joint (7°). In typically developed individuals there were relatively smaller contributions (10 -11%) by foot deformation to changes in foot plate angle, indicating that the contribution of talocrural angle changes was most important. Using a new estimate for position at the talocrural joint (the difference between GM muscle–tendon complex length and tibia length, GM relative length) removed this effect, thus allowing more fair comparison of SCP and TD data. On the basis of analysis of foot plate angle and GM relative length as a function of externally applied moments, it is concluded that foot plate angle measurements underestimate angular changes at the talocrural joint when moving in dorsal flexion direction and overestimate them when moving in plantar flexion direction, with concomitant effects on triceps surae lengths. Conclusions In SCP children diagnosed with decreased dorsal ROM of the ankle joint, the commonly used measure (i.e. range of foot plate angle), is not a good estimate of rotation at the talocrural joint. since a sizable part of the movement of the foot (or foot plate) derives from internal deformation of the foot. PMID:24364826
Bennour, Sami; Ulrich, Baptiste; Legrand, Thomas; Jolles, Brigitte M; Favre, Julien
2018-01-03
Improving lower-limb flexion/extension angles during walking is important for the treatment of numerous pathologies. Currently, these gait retraining procedures are mostly qualitative, often based on visual assessment and oral instructions. This study aimed to propose an alternative method combining motion capture and display of target footprints on the floor. The second objectives were to determine the error in footprint modifications and the effects of footprint modifications on lower-limb flexion/extension angles. An augmented-reality system made of an optoelectronic motion capture device and video projectors displaying target footprints on the floor was designed. 10 young healthy subjects performed a series of 27 trials, consisting of increased and decreased amplitudes in stride length, step width and foot progression angle. 11 standard features were used to describe and compare lower-limb flexion/extension angles among footprint modifications. Subjects became accustomed to walk on target footprints in less than 10 min, with mean (± SD) precision of 0.020 ± 0.002 m in stride length, 0.022 ± 0.006 m in step width, and 2.7 ± 0.6° in progression angle. Modifying stride length had significant effects on 3/3 hip, 2/4 knee and 4/4 ankle features. Similarly, step width and progression angle modifications affected 2/3 and 1/3 hip, 2/4 and 1/4 knee as well as 3/4 and 2/4 ankle features, respectively. In conclusion, this study introduced an augmented-reality method allowing healthy subjects to modify their footprint parameters rapidly and precisely. Walking with modified footprints changed lower-limb sagittal-plane kinematics. Further research is needed to design rehabilitation protocols for specific pathologies. Copyright © 2017 Elsevier Ltd. All rights reserved.
Luna-Pizarro, Daniel; Amato, Dante; Arellano, Francisco; Hernández, Armando; López-Rojas, Pablo
2006-09-01
To compare the percutaneous patellar osteosynthesis system (PPOS) technique with open surgery for patella fractures. Randomized controlled trial. Referral orthopedic and trauma center. Fifty-three patients with displaced patellar fractures. Stabilization and fixation of patellar fractures with PPOS or open surgery. Knee-flexion and -extension angles, pain, surgical time, and assessment of knee function based on the Knee Society Clinical Rating Scale (KSCRS). Comparison of PPOS and open-surgery groups at 4 weeks showed the following: pain, 3.7 +/- 1.6 versus 6.2 +/- 1.4 arbitrary units, P < 0.001; flexion angle, 46 +/- 20.7 versus 12.7 +/- 6.0 degrees, P < 0.001; extension angle, -2.5 versus -3.8 degrees, P < 0.001. At 8 weeks, the following was demonstrated: pain, 1.3 +/- 1.6 versus 4.1 +/- 2.1 arbitrary units, P < 0.001; flexion angle, 87 +/- 17.3 versus 34 +/- 26 degrees, P < 0.001; extension angle, 0 versus -3 degrees, P < 0.001. Surgical time was 35.3 +/- 7.8 versus 66.2 +/- 14.1 minutes, P < 0.001. KSCRS assessment was 84 +/- 4 versus 70 +/- 8, P < 0.001 at 8 weeks; 85 +/- 2 versus 73 +/- 8, P < 0.001 at 12 months; and 85 +/- 1 versus 82 +/- 7, P = 0.246 at 24 months. Frequency of total complications (infections, fragment displacement, and wire-related pain) was significantly lower in the PPOS than in the open-surgery group (P < 0.02). PPOS for patella fractures was associated with shorter surgical time, less pain, better mobility angles, higher functional score up to 2 years, and a lower incidence of complications than open surgery.
Newman, Mark A; Hirsch, Mark A; Peindl, Richard D; Habet, Nahir A; Tsai, Tobias J; Runyon, Michael S; Huynh, Toan; Zheng, Nigel
2018-06-01
Studies have evaluated the test-re-test reliability of subcomponents of the timed up and-go test in adults by using body-worn inertial sensors. However, studies in children have not been reported in the literature. To evaluate the within-session reliability of subcomponents of a newly developed electronically augmented timed 'upand-go' test (EATUG) in ambulatory children with traumatic brain injury (TBI) and children with typical development (TD). The timed up and go test was administered to twelve consecutive ambulatory children with moderate to severe TBI (6 males and 6 females, age 10.5 ± 1.5 years, range 8-13 years, during inpatient rehabilitation at 27.0 ± 11.8 days following injury) and 10 TD age and sex-matched children (5 males and 5 females, 10.4 ± 1.3 years, range 8-11 years). Participants wore a single chest-mounted inertial measurement sensor package with custom software that measured angular and acceleration velocity and torso flexion and extension angles, while they performed 6 trials of the EATUG test. Measures were derived from the overall time to complete the TUG test, angular velocity and angular displacement data for torso flexion and extension during sit-to-stand and stand-to-sit segments and both mean and peak angular velocities for two turning segments (i.e. turning around a cone and turning-before-sitting). Within-session reliability of the subcomponents of the TUG test for children with TBI assessed by the intra-class correlation coefficient was ICC (1,1) = 0.84, (range 0.82-0.96), and for TD children ICC (1,1) = 0.73, (range 0.53-0.89). Scores on Total Time, maximum torso flexion/extension angle and peak flexion angular velocity during sit-tostand, and peak turn angular velocity for both turns around the cone and turns before sitting were lower for children with TBI than for TD children (p ≤ 0.05). The EATUG test is a reliable measure of physical function in children with TBI who are being discharged from inpatient rehabilitation. Copyright © 2018 Elsevier B.V. All rights reserved.
Muyor, José M; Alacid, Fernando; López-Miñarro, Pedro A
2011-09-01
The purpose of this study was to determine the influence of hamstring muscles extensibility in standing, maximal trunk flexion with knees extended and on the bicycle in lower handlebar-hands position of highly trained cyclists. Ninety-six cyclists were recruited for the study (mean ± SD, age: 30.36 ± 5.98 years). Sagittal spinal curvatures and pelvic tilt were measured in the standing position, maximal trunk flexion with knees extended (sit-and-reach test) and while sitting on a bicycle in lower handlebar-hand position using a Spinal Mouse system. Hamstring muscles extensibility was determined in both legs by passive straight leg raise test (PSLR). The sample was divided into three groups according to PSLR angle: (1) reduced extensibility (PSLR < 80º; n = 30), (2) moderate hamstring extensibility group (PSLR = 80º - 90º; n = 35), and (3) high hamstring extensibility (PSLR = > 90º; n = 31). ANOVA analysis showed significant differences among groups for thoracic (p < 0.001) and pelvic tilt (p < 0.001) angles in the sit-and-reach test. No differences were found between groups for standing and on the bicycle position. Post hoc analysis showed significant differences in all pairwise comparisons for thoracic angle (p < 0.01) and pelvic angle (p < 0.001) in the sit-and-reach test. No differences were found in lumbar angle in any posture. In conclusion, the hamstring muscles extensibility influence the thoracic and pelvic postures when maximal trunk flexion with knees extended is performed, but not when cyclists are seated on their bicycles.
Muyor, José M.; Alacid, Fernando; López-Miñarro, Pedro A.
2011-01-01
The purpose of this study was to determine the influence of hamstring muscles extensibility in standing, maximal trunk flexion with knees extended and on the bicycle in lower handlebar-hands position of highly trained cyclists. Ninety-six cyclists were recruited for the study (mean ± SD, age: 30.36 ± 5.98 years). Sagittal spinal curvatures and pelvic tilt were measured in the standing position, maximal trunk flexion with knees extended (sit-and-reach test) and while sitting on a bicycle in lower handlebar-hand position using a Spinal Mouse system. Hamstring muscles extensibility was determined in both legs by passive straight leg raise test (PSLR). The sample was divided into three groups according to PSLR angle: (1) reduced extensibility (PSLR < 80º; n = 30), (2) moderate hamstring extensibility group (PSLR = 80º – 90º; n = 35), and (3) high hamstring extensibility (PSLR = > 90º; n = 31). ANOVA analysis showed significant differences among groups for thoracic (p < 0.001) and pelvic tilt (p < 0.001) angles in the sit-and-reach test. No differences were found between groups for standing and on the bicycle position. Post hoc analysis showed significant differences in all pairwise comparisons for thoracic angle (p < 0.01) and pelvic angle (p < 0.001) in the sit-and-reach test. No differences were found in lumbar angle in any posture. In conclusion, the hamstring muscles extensibility influence the thoracic and pelvic postures when maximal trunk flexion with knees extended is performed, but not when cyclists are seated on their bicycles PMID:23486997
Effect of Knee Joint Angle and Contraction Intensity on Hamstrings Coactivation.
Wu, Rui; Delahunt, Eamonn; Ditroilo, Massimiliano; Lowery, Madeleine M; DE Vito, Giuseppe
2017-08-01
This study investigated the effect of knee joint angle and contraction intensity on the coactivation of the hamstring muscles (when acting as antagonists to the quadriceps) in young and older individuals of both sexes. A total of 25 young (24 ± 2.6 yr) and 26 older (70 ± 2.5 yr) healthy men and women participated. Maximal voluntary isometric contraction of the knee extensors and flexors was assessed at two knee joint angles (90° and 60°, 0° = full extension). At each angle, participants performed submaximal contractions of the knee extensors (20%, 50%, and 80% maximal voluntary isometric contraction), whereas surface EMG was simultaneously acquired from the vastus lateralis and biceps femoris muscles to assess the level (EMG root-mean-square) of agonist activation and antagonist coactivation. Subcutaneous adipose tissue in the areas corresponding to surface EMG electrode placements was measured via ultrasonography. The contractions performed at 90° knee flexion demonstrated higher levels of antagonist coactivation (all P < 0.01) and agonist activation (all P < 0.01) as a function of contraction intensity compared with the 60° knee flexion. Furthermore, after controlling for subcutaneous adipose tissue, older participants exhibited a higher level of antagonist coactivation at 60° knee flexion compared with young participants (P < 0.05). The results of the present study suggest that 1) the antagonist coactivation is dependent on knee joint angle and contraction intensity and 2) subcutaneous adipose tissue may affect the measured coactivation level likely because of a cross-talk effect. Antagonist coactivation may play a protective role in stabilizing the knee joint and maintaining constant motor output.
Slack length of gastrocnemius medialis and Achilles tendon occurs at different ankle angles.
Hug, François; Lacourpaille, Lilian; Maïsetti, Olivier; Nordez, Antoine
2013-09-27
Although muscle-tendon slack length is a crucial parameter used in muscle models, this is one of the most difficult measures to estimate in vivo. The aim of this study was to determine the onset of the rise in tension (i.e., slack length) during passive stretching in both Achilles tendon and gastrocnemius medialis. Muscle and tendon shear elastic modulus was measured by elastography (supersonic shear imaging) during passive plantarflexion (0° and 90° of knee angle, 0° representing knee fully extended, in a random order) in 9 participants. The within-session repeatability of the determined slack length was good at 90° of knee flexion (SEM=3.3° and 2.2° for Achilles tendon and gastrocnemius medialis, respectively) and very good at 0° of knee flexion (SEM=1.9° and 1.9° for Achilles tendon and gastrocnemius medialis, respectively). The slack length of gastrocnemius medialis was obtained at a significantly lower plantarflexed angle than for Achilles tendon at both 0° (P<0.0001; mean difference=19.4±3.8°) and 90° of knee flexion (P<0.0001; mean difference=25.5±7.6°). In conclusion, this study showed that the joint angle at which the tendon falls slack can be experimentally determined using supersonic shear imaging. The slack length of gastrocnemius medialis and Achilles tendon occurred at different joint angles. Although reporting this result is crucial to a better understanding of muscle-tendon interactions, further experimental investigations are required to explain this result. Copyright © 2013 Elsevier Ltd. All rights reserved.
What is the impingement-free range of motion of the asymptomatic hip in young adult males?
Larkin, Brian; van Holsbeeck, Marnix; Koueiter, Denise; Zaltz, Ira
2015-04-01
Femoroacetabular impingement is a recognized cause of chondrolabral injury. Although surgical treatment for impingement seeks to improve range of motion, there are very little normative data on dynamic impingement-free hip range of motion (ROM) in asymptomatic people. Hip ultrasound demonstrates labral anatomy and femoral morphology and, when used dynamically, can assist in measuring range of motion. The purposes of this study were (1) to measure impingement-free hip ROM until labral deflection is observed; and (2) to measure the maximum degree of sagittal plane hip flexion when further flexion is limited by structural femoroacetabular abutment. Forty asymptomatic adult male volunteers (80 hips) between the ages of 21 and 35 years underwent bilateral static and dynamic hip ultrasound examination. Femoral morphology was characterized and midsagittal flexion passive ROM was measured at two points: (1) at the initiation of labral deformation; and (2) at maximum flexion when the femur impinged on the acetabular rim. The mean age of the subjects was 28 ± 3 years and the mean body mass index was 25 ± 4 kg/m(2). Mean impingement-free hip passive flexion measured from full extension to initial labral deflection was 68° ± 17° (95% confidence interval [CI], 65-72). Mean maximum midsagittal passive flexion, measured at the time of bony impingement, was 96° ± 6° (95% CI, 95-98). Using dynamic ultrasound, we found that passive ROM in the asymptomatic hip was much less than the motion reported in previous studies. Measuring ROM using ultrasound is more accurate because it allows anatomic confirmation of terminal hip motion. Surgical procedures used to treat femoroacetabular impingement are designed to restore or increase hip ROM and their results should be evaluated in light of precise normative data. This study suggests that normal passive impingement-free femoroacetabular flexion in the young adult male is approximately 95°.
The effect of simulated microgravity on lumbar spine biomechanics: an in vitro study.
Laws, Cory J; Berg-Johansen, Britta; Hargens, Alan R; Lotz, Jeffrey C
2016-09-01
Disc herniation risk is quadrupled following spaceflight. This study tested the hypothesis that swelling-induced disc height increases (comparable to those reported in spaceflight) stiffen the spine and elevate annular strain and nuclear pressure during forward bending. Eight human lumbar motion segments were secured to custom-designed testing jigs and subjected to baseline flexion and compression and pure moment flexibility tests. Discs were then free-swelled in saline to varying supraphysiologic heights consistent with prolonged weightlessness and re-tested to assess biomechanical changes. Swelling-induced disc height changes correlated positively with intradiscal pressure (p < 0.01) and stiffening in flexion (p < 0.01), and negatively with flexion range of motion (p < 0.05). Swelling-induced increases in disc height also led to increased annular surface strain under combined flexion with compression. Disc wedge angle decreased with swelling (p < 0.05); this loss of wedge angle correlated with decreased flexion range of motion (R (2) = 0.94, p < 0.0001) and decreased stiffness fold change in extension (p < 0.05). Swelling-induced increases in disc height decrease flexibility and increase annular strain and nuclear pressure during forward bending. These changes, in combination with the measured loss of lordotic curvature with disc swelling, may contribute toward increased herniation risk. This is consistent with clinical observations of increased disc herniation rates after microgravity exposure and may provide the basis for future countermeasure development.
Influence of trunk posture on lower extremity energetics during running.
Teng, Hsiang-Ling; Powers, Christopher M
2015-03-01
This study aimed to examine the influence of sagittal plane trunk posture on lower extremity energetics during running. Forty asymptomatic recreational runners (20 males and 20 females) ran overground at a speed of 3.4 m·s(-1). Sagittal plane trunk kinematics and lower extremity kinematics and energetics during the stance phase of running were computed. Subjects were dichotomized into high flexion (HF) and low flexion (LF) groups on the basis of the mean trunk flexion angle. The mean (±SD) trunk flexion angles of the HF and LF groups were 10.8° ± 2.2° and 3.6° ± 2.8°, respectively. When compared with the LF group, the HF group demonstrated significantly higher hip extensor energy generation (0.12 ± 0.06 vs 0.05 ± 0.04 J·kg(-1), P < 0.001) and lower knee extensor energy absorption (0.60 ± 0.14 vs 0.74 ± 0.09 J·kg(-1), P = 0.001) and generation (0.30 ± 0.05 vs 0.34 ± 0.06 J·kg(-1), P = 0.02). There was no significant group difference for the ankle plantarflexor energy absorption or generation (P > 0.05). Sagittal plane trunk flexion has a significant influence on hip and knee energetics during running. Increasing forward trunk lean during running may be used as a strategy to reduce knee loading without increasing the biomechanical demand at the ankle plantarflexors.
The effect of simulated microgravity on lumbar spine biomechanics: an in vitro study
Laws, Cory J.; Berg-Johansen, Britta; Hargens, Alan R.; Lotz, Jeffrey C.
2015-01-01
Purpose Disc herniation risk is quadrupled following spaceflight. This study tested the hypothesis that swelling-induced disc height increases (comparable to those reported in spaceflight) stiffen the spine and elevate annular strain and nuclear pressure during forward bending. Methods Eight human lumbar motion segments were secured to custom-designed testing jigs and subjected to baseline flexion and compression and pure moment flexibility tests. Discs were then free-swelled in saline to varying supraphysiologic heights consistent with prolonged weightlessness and re-tested to assess biomechanical changes. Results Swelling-induced disc height changes correlated positively with intradiscal pressure (p < 0.01) and stiffening in flexion (p < 0.01), and negatively with flexion range of motion (p < 0.05). Swelling-induced increases in disc height also led to increased annular surface strain under combined flexion with compression. Disc wedge angle decreased with swelling (p < 0.05); this loss of wedge angle correlated with decreased flexion range of motion (R2 = 0.94, p < 0.0001) and decreased stiffness fold change in extension (p < 0.05). Conclusion Swelling-induced increases in disc height decrease flexibility and increase annular strain and nuclear pressure during forward bending. These changes, in combination with the measured loss of lordotic curvature with disc swelling, may contribute toward increased herniation risk. This is consistent with clinical observations of increased disc herniation rates after microgravity exposure and may provide the basis for future countermeasure development. PMID:26403291
Lura, Derek J; Wernke, Matthew M; Carey, Stephanie L; Kahle, Jason T; Miro, Rebecca M; Highsmith, M Jason
2015-02-01
Microprocessor knees have improved the gait and functional abilities of persons with transfemoral amputation. The Genium prosthetic knee offers an advanced sensor and control system designed to decrease impairment by: allowing greater stance phase flexion, easing transitions between gait phases, and compensating for changes in terrain. The aim of this study was to determine differences between the knee flexion angle of persons using the Genium knee, the C-Leg knee, and non-amputee controls; and to evaluate the impact the prostheses on gait and level of impairment of the user. This study used a randomized experimental crossover of persons with transfemoral amputation using the Genium and C-Leg microprocessor knees (n=25), with an observational sample of non-amputee controls (n=5). Gait analysis by 3D motion tracking of subjects ambulating at different speeds on level ground and on 5° and 10° ramps was completed. Use of the Genium resulted in a significant increase in peak knee flexion for swing (5°, p<0.01, d=0.34) and stance (2°, p<0.01, d=0.19) phases relative to C-Leg use. There was a high degree of variability between subjects, and significant differences still remain between the Genium group and the control group's knee flexion angles for most speeds and slopes. The Genium knee generally increases flexion in swing and stance, potentially decreasing the level of impairment for persons with transfemoral amputation. This study demonstrates functional differences between the C-Leg and Genium knees to help prosthetists determine if the Genium will provide functional benefits to individual patients. Copyright © 2014 Elsevier Ltd. All rights reserved.
Lumbar Corsets Can Decrease Lumbar Motion in Golf Swing
Hashimoto, Koji; Miyamoto, Kei; Yanagawa, Takashi; Hattori, Ryo; Aoki, Takaaki; Matsuoka, Toshio; Ohno, Takatoshi; Shimizu, Katsuji
2013-01-01
Swinging a golf club includes the rotation and extension of the lumbar spine. Golf-related low back pain has been associated with degeneration of the lumbar facet and intervertebral discs, and with spondylolysis. Reflective markers were placed directly onto the skin of 11young male amateur golfers without a previous history of back pain. Using a VICON system (Oxford Metrics, U.K.), full golf swings were monitored without a corset (WOC), with a soft corset (SC), and with a hard corset (HC), with each subject taking 3 swings. Changes in the angle between the pelvis and the thorax (maximum range of motion and angular velocity) in 3 dimensions (lumbar rotation, flexion-extension, and lateral tilt) were analyzed, as was rotation of the hip joint. Peak changes in lumbar extension and rotation occurred just after impact with the ball. The extension angle of the lumbar spine at finish was significantly lower under SC (38°) or HC (28°) than under WOC (44°) conditions (p < 0.05). The maximum angular velocity after impact was significantly smaller under HC (94°/sec) than under SC (177°/sec) and WOC (191° /sec) conditions, as were the lumbar rotation angles at top and finish. In contrast, right hip rotation angles at top showed a compensatory increase under HC conditions. Wearing a lumbar corset while swinging a golf club can effectively decrease lumbar extension and rotation angles from impact until the end of the swing. These effects were significantly enhanced while wearing an HC. Key points Rotational and extension forces on the lumbar spine may cause golf-related low back pain Wearing lumbar corsets during a golf swing can effectively decrease lumbar extension and rotation angles and angular velocity. Wearing lumbar corsets increased the rotational motion of the hip joint while reducing the rotation of the lumbar spine. PMID:24149729
Lumbar corsets can decrease lumbar motion in golf swing.
Hashimoto, Koji; Miyamoto, Kei; Yanagawa, Takashi; Hattori, Ryo; Aoki, Takaaki; Matsuoka, Toshio; Ohno, Takatoshi; Shimizu, Katsuji
2013-01-01
Swinging a golf club includes the rotation and extension of the lumbar spine. Golf-related low back pain has been associated with degeneration of the lumbar facet and intervertebral discs, and with spondylolysis. Reflective markers were placed directly onto the skin of 11young male amateur golfers without a previous history of back pain. Using a VICON system (Oxford Metrics, U.K.), full golf swings were monitored without a corset (WOC), with a soft corset (SC), and with a hard corset (HC), with each subject taking 3 swings. Changes in the angle between the pelvis and the thorax (maximum range of motion and angular velocity) in 3 dimensions (lumbar rotation, flexion-extension, and lateral tilt) were analyzed, as was rotation of the hip joint. Peak changes in lumbar extension and rotation occurred just after impact with the ball. The extension angle of the lumbar spine at finish was significantly lower under SC (38°) or HC (28°) than under WOC (44°) conditions (p < 0.05). The maximum angular velocity after impact was significantly smaller under HC (94°/sec) than under SC (177°/sec) and WOC (191° /sec) conditions, as were the lumbar rotation angles at top and finish. In contrast, right hip rotation angles at top showed a compensatory increase under HC conditions. Wearing a lumbar corset while swinging a golf club can effectively decrease lumbar extension and rotation angles from impact until the end of the swing. These effects were significantly enhanced while wearing an HC. Key pointsRotational and extension forces on the lumbar spine may cause golf-related low back painWearing lumbar corsets during a golf swing can effectively decrease lumbar extension and rotation angles and angular velocity.Wearing lumbar corsets increased the rotational motion of the hip joint while reducing the rotation of the lumbar spine.
Ahn, Jin Hwan; Bae, Tae Soo; Kang, Ki-Ser; Kang, Soo Yong; Lee, Sang Hak
2011-10-01
Longitudinal tears of the medial meniscus posterior horn (MMPH) are commonly associated with a chronic anterior cruciate ligament (ACL) deficiency. Many studies have demonstrated the importance of the medial meniscus in terms of limiting the amount of anterior-posterior tibial translation in response to anterior tibial loads in ACL-deficient knees. An MMPH tear in an ACL-deficient knee increases the anterior-posterior tibial translation and rotatory instability. In addition, MMPH repair will restore the tibial translation to the level before the tear. Controlled laboratory study. Ten human cadaveric knees were tested sequentially using a custom testing system under 5 conditions: intact, ACL deficient, ACL deficient with an MMPH peripheral longitudinal tear, ACL deficient with an MMPH repair, and ACL deficient with a total medial meniscectomy. The knee kinematics were measured at 0°, 15°, 30°, 60°, and 90° of flexion in response to a 134-N anterior and 200-N axial compressive tibial load. The rotatory kinematics were also measured at 15° and 30° of flexion in a combined rotatory load of 5 N·m of internal tibial torque and 10 N·m of valgus torque. Medial meniscus posterior horn longitudinal tears in ACL-deficient knees resulted in a significant increase in anterior-posterior tibial translation at all flexion angles except 90° (P < .05). An MMPH repair in an ACL-deficient knee showed a significant decrease in anterior-posterior tibial translation at all flexion angles except 60° compared with the ACL-deficient/MMPH tear state (P < .05). The total anterior-posterior translation of the ACL-deficient/MMPH repaired knee was not significantly increased compared with the ACL (only)-deficient knee but was increased compared with the ACL-intact knee (P > .05). A total medial meniscectomy in an ACL-deficient knee did not increase the anterior-posterior tibial translation significantly compared with MMPH tears in ACL-deficient knees at all flexion angles (P > .05). In a combined rotatory load, tibial rotation after MMPH tears or a total medial meniscectomy in an ACL-deficient knee were not affected significantly at all flexion angles. This study shows that an MMPH longitudinal tear in an ACL-deficient knee alters the knee kinematics, particularly the anterior-posterior tibial translation. MMPH repair significantly improved anterior-posterior tibial translation in ACL-deficient knees. These findings may help improve the treatment of patients with ACL and MMPH longitudinal tear by suggesting that the medial meniscal repairs should be performed for greater longevity when combined with an ACL reconstruction.
Cranial cruciate stability in the rottweiler and racing greyhound: an in vitro study.
Wingfield, C; Amis, A A; Stead, A C; Law, H T
2000-05-01
An in vitro biomechanical study of cadaver stifles from rottweilers and racing greyhounds was undertaken to evaluate the contribution of the cranial cruciate ligament to stifle joint stability. This was performed at differing stifle joint angles, first with the joint capsules and ligaments intact and then with all structures removed except for the cranial cruciate ligament. Craniocaudal laxity increased in both breeds as stifle flexion increased. The rottweiler stifle showed greater craniocaudal joint laxity than the racing greyhound at all joint angles between 150 degrees and 110 degrees, but the actual increases in joint laxity between these joint angles were similar for both breeds. Tibial rotation during craniocaudal loading of the stifle increased craniocaudal laxity in both breeds during joint flexion. The relative contribution of the cranial cruciate ligament to cranial stability of the stifle joint increased as the joint flexed and was similar in both breeds.
Direct dynamics simulation of the impact phase in heel-toe running.
Gerritsen, K G; van den Bogert, A J; Nigg, B M
1995-06-01
The influence of muscle activation, position and velocities of body segments at touchdown and surface properties on impact forces during heel-toe running was investigated using a direct dynamics simulation technique. The runner was represented by a two-dimensional four- (rigid body) segment musculo-skeletal model. Incorporated into the muscle model were activation dynamics, force-length and force-velocity characteristics of seven major muscle groups of the lower extremities: mm. glutei, hamstrings, m. rectus femoris, mm. vasti, m. gastrocnemius, m. soleus and m. tibialis anterior. The vertical force-deformation characteristics of heel, shoe and ground were modeled by a non-linear visco-elastic element. The maximum of a typical simulated impact force was 1.6 times body weight. The influence of muscle activation was examined by generating muscle stimulation combinations which produce the same (experimentally determined) resultant joint moments at heelstrike. Simulated impact peak forces with these different combinations of muscle stimulation levels varied less than 10%. Without this restriction on initial joint moments, muscle activation had potentially a much larger effect on impact force. Impact peak force was to a great extent influenced by plantar flexion (85 N per degree of change in foot angle) and vertical velocity of the heel (212 N per 0.1 m s-1 change in velocity) at touchdown. Initial knee flexion (68 N per degree of change in leg angle) also played a role in the absorption of impact. Increased surface stiffness resulted in higher impact peak forces (60 N mm-1 decrease in deformation).(ABSTRACT TRUNCATED AT 250 WORDS)
Koblbauer, Ian F; van Schooten, Kimberley S; Verhagen, Evert A; van Dieën, Jaap H
2014-07-01
This study aimed to investigate kinematic changes experienced during running-induced fatigue. Further, the study examined relations between kinematic changes and core endurance. Repeated measures and correlation. Seventeen novice runners participated in a running-induced fatigue protocol and underwent core endurance assessment. Participants ran at a steady state corresponding to an intensity of 13 on the Borg scale and continued until 2min after a Borg score of 17 or 90% of maximum heart rate was reached. Kinematic data were analyzed for the lower extremities and trunk throughout a running protocol and, on separate days, core endurance measures were recorded. Changes in pre- and post-fatigue running kinematics and their relations with core endurance measures were analyzed. Analysis of peak joint angles revealed significant increases in trunk flexion (4°), decreases in trunk extension (3°), and increases in non-dominant ankle eversion (1.6°) as a result of running-induced fatigue. Post-fatigue increased trunk flexion changes displayed a strong to moderate positive relation with trunk extensor core endurance measures, in contrast to expected negative relations. Novice runners displayed an overall increase in trunk inclination and increased ankle eversion peak angles when fatigued utilizing a running-induced fatigue protocol. As most pronounced changes were found for the trunk, trunk kinematics appear to be significantly affected during fatigued running and should not be overlooked. Core endurance measures displayed unexpected relations with running kinematics and require further investigation to determine the significance of these relations. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Yosmaoğlu, Hayri Baran; Baltacı, Gül; Sönmezer, Emel; Özer, Hamza; Doğan, Deha
2017-12-01
This study aims to compare the effects of anterior cruciate ligament (ACL) reconstruction using autogenous hamstring or patellar tendon graft on the peak torque angle. The study included 132 patients (103 males, 29 females; mean age 29±9 year) who were performed ACL reconstruction with autogenous hamstring or patellar tendon graft. The peak torque angles in the quadriceps and hamstring muscles were recorded using an isokinetic dynamometer. Angle of peak knee flexion torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the hamstring tendon group. Angle of peak knee extension torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the patellar tendon group. There were no statistically significant differences in the flexion and extension peak torque angles between the operated and nonoperated knees at 60°/second in both groups. The angle of peak torque at relatively high angular velocities is affected after ACL reconstruction in patients with hamstring or patellar tendon grafts. The graft donor site directly influences this parameter. This finding may be important for clinicians in terms of preventing re-injury.
A mathematical model of forces in the knee under isometric quadriceps contractions.
Huss, R A; Holstein, H; O'Connor, J J
2000-02-01
To predict the knee's response to isometric quadriceps contractions against a fixed tibial restraint.Design. Mathematical modelling of the human knee joint. Isometric quadriceps contraction is commonly used for leg muscle strengthening following ligament injury or reconstruction. It is desirable to know the ligament forces induced but direct measurement is difficult. The model, previously applied to the Lachmann or 'drawer' tests, combines an extensible fibre-array representation of the cruciate ligaments with a compressible 'thin-layer' representation of the cartilage. The model allows the knee configuration and force system to be calculated, given flexion angle, restraint position and loading. Inclusion of cartilage deformation increases relative tibio-femoral translation and decreases the ligament forces generated. For each restraint position, a range of flexion angles is found in which no ligament force is required, as opposed to a single flexion angle in the case of incompressible cartilage layers. Knee geometry and ligament elasticity are found to be the most important factors governing the joint's response to isometric quadriceps contractions, but cartilage deformation is found to be more important than in the Lachmann test. Estimation of knee ligament forces is important when devising exercise regimes following ligament injury or reconstruction. The finding of a 'neutral zone' of zero ligament force may have implications for rehabilitation of the ligament-injured knee.
Dai, Yifei; Cross, Michael B; Angibaud, Laurent D; Hamad, Cyril; Jung, Amaury; Jenny, Jean-Yves
2018-02-23
Posterior tibial slope (PTS) for cruciate-retaining (CR) total knee arthroplasty (TKA) is usually pre-determined by the surgeon. Limited information is available comparing different choices of PTS on the kinematics of the CR TKA, independent of the balancing of the extension gap. This study hypothesized that with the same balanced extension gap, the choice of PTS significantly impacts the intraoperatively measured kinematics of CR TKA. Navigated CR TKAs were performed on seven fresh-frozen cadavers with healthy knees and intact posterior cruciate ligament (PCL). A custom designed tibial baseplate was implanted to allow in situ modification of the PTS, which altered the flexion gap but maintained the extension gap. Knee kinematics were measured by performing passive range of motion (ROM) tests from full extension to 120° of flexion on the intact knee and CR TKAs with four different PTSs (1°, 4°, 7°, and 10°). The measured kinematics were compared across test conditions to assess the impact of PTS. With a consistent extension gap, the change of PTS had significant impact on the anteroposterior (AP) kinematics of the CR TKA knees in mid-flexion range (45°-90°), but not so much for the high-flexion range (90°-120°). No considerable impacts were found on internal/external (I/E) rotation and hip-knee-ankle (HKA) angle. However, the findings on the individual basis suggested the impact of PTS on I/E rotation and HKA angle may be patient-specific. The data suggested that the choice of PTS had the greatest impact on the mid-flexion AP translation among the intraoperatively measured kinematics. This impact may be considered while making surgical decisions in the context of AP kinematics. When using a tibial component designed with "center" pivoting PTS, a surgeon may be able to fine tune the PTS to achieve proper mid-flexion AP stability.
Lee, Han Suk; Chung, Hyung Kuk; Park, Sun Wook
2015-01-01
Objective. To assess the correlation of abnormal trunk postures and reposition sense of subjects with forward head neck posture (FHP). Methods. In all, postures of 41 subjects were evaluated and the FHP and trunk posture including shoulder, scapular level, pelvic side, and anterior tilting degrees were analyzed. We used the head repositioning accuracy (HRA) test to evaluate neck position senses of neck flexion, neck extension, neck right and left side flexion, and neck right and left rotation and calculated the root mean square error in trials for each subject. Spearman's rank correlation coefficients and regression analysis were used to assess the degree of correlation between the trunk posture and HRA value, and a significance level of α = 0.05 was considered. Results. There were significant correlations between the HRA value of right side neck flexion and pelvic side tilt angle (p < 0.05). If pelvic side tilting angle increases by 1 degree, right side neck flexion increased by 0.76 degrees (p = 0.026). However, there were no significant correlations between other neck motions and trunk postures. Conclusion. Verifying pelvic postures should be prioritized when movement is limited due to the vitiation of the proprioceptive sense of neck caused by FHP. PMID:26583125
Revision ulnar collateral ligament reconstruction using a suspension button fixation technique.
Lee, Gregory H; Limpisvasti, Orr; Park, Maxwell C; McGarry, Michelle H; Yocum, Lewis A; Lee, Thay Q
2010-03-01
Revision ulnar collateral ligament reconstruction remains a challenging problem. The objective of this study was to biomechanically evaluate an ulnar collateral ligament reconstruction technique using a suspension button fixation technique that can be used even in the case of ulnar cortical bone loss. An ulnar suspension fixation technique for ulnar collateral ligament reconstruction can restore elbow kinematics and demonstrate failure strength comparable to that of currently available techniques. Controlled laboratory study. Nine pairs of cadaveric elbows were dissected free of soft tissue and potted. After simulating ulnar cortical bone loss, ulnar collateral ligament reconstruction was performed in 1 elbow of each pair using palmaris longus autograft and a 30-mm RetroButton suspended from the far (lateralmost) ulnar cortex. A docking technique was used for humeral fixation of the graft. Elbow valgus angle was quantified using a Microscribe 3DLX digitizer at multiple elbow flexion angles. Valgus angle was measured with the ulnar collateral ligament intact, transected, and reconstructed. In addition, load-to-failure testing was performed in 1 elbow of each pair. Release of the ulnar collateral ligament caused a significant increase in valgus angle at each flexion angle tested (P < .002). Reconstructed elbows demonstrated no significant differences in valgus angle from the intact elbow at all flexion angles tested. Load-to-failure tests showed that reconstructed elbows had an ultimate torque (10.3 + or - 5.7 N x m) significantly less than intact elbows (26.4 + or - 10.6 N x m) (P = .001). Ulnar collateral ligament reconstruction using a suspension button fixation technique reliably restored elbow kinematics to the intact state. Load-to-failure testing demonstrated comparable fixation strength to several historic controls of primary reconstruction techniques despite the simulated ulnar cortical bone loss. Ulnar collateral ligament reconstruction using a suspension button fixation technique can be considered in the case of ulnar cortical bone loss in a primary or revision setting.
Experimental measurement of flexion-extension movement in normal and corpse prosthetic elbow joint.
TarniŢă, Daniela; TarniŢă, DănuŢ Nicolae
2016-01-01
This paper presents a comparative experimental study of flexion-extension movement in healthy elbow and in the prosthetic elbow joint fixed on an original experimental bench. Measurements were carried out in order to validate the functional morphology and a new elbow prosthesis type ball head. The three-dimensional (3D) model and the physical prototype of our experimental bench used to test elbow endoprosthesis at flexion-extension and pronation-supination movements is presented. The measurements were carried out on a group of nine healthy subjects and on the prosthetic corpse elbow, the experimental data being obtained for flexion-extension movement cycles. Experimental data for the two different flexion-extension tests for the nine subjects and for the corpse prosthetic elbow were acquired using SimiMotion video system. Experimental data were processed statistically. The corresponding graphs were obtained for all subjects in the experimental group, and for corpse prosthetic elbow for both flexion-extension tests. The statistical analysis has proved that the flexion angles of healthy elbows were significantly close to the values measured at the prosthetic elbow fixed on the experimental bench. The studied elbow prosthesis manages to re-establish the mobility for the elbow joint as close to the normal one.
Stock, J D; Calderón Díaz, J A; Rothschild, M F; Mote, B E; Stalder, K J
2018-06-09
Feet and legs of replacement females were objectively evaluated at selection, i.e. approximately 150 days of age (n=319) and post first parity, i.e. any time after weaning of first litter and before 2nd parturition (n=277) to 1) compare feet and leg joint angle ranges between selection and post first parity; 2) identify feet and leg joint angle differences between selection and first three weeks of second gestation; 3) identify feet and leg join angle differences between farms and gestation days during second gestation; and 4) obtain genetic variance components for conformation angles for the two time points measured. Angles for carpal joint (knee), metacarpophalangeal joint (front pastern), metatarsophalangeal joint (rear pastern), tarsal joint (hock), and rear stance were measured using image analysis software. Between selection and post first parity significant differences were observed for all joints measured (P < 0.05). Knee, front and rear pastern angles were less (more flexion), and hock angles were greater (less flexion) as age progressed (P < 0.05), while the rear stance pattern was less (feet further under center) at selection than post first parity (only including measures during first three weeks of second gestation). Only using post first parity leg conformation information, farm was a significant source of variation for front and rear pasterns and rear stance angle measurements (P < 0.05). Knee angle was less (more flexion) (P < 0.05) as gestation age progressed. Heritability estimates were low to moderate (0.04 - 0.35) for all traits measured across time points. Genetic correlations between the same joints at different time points were high (> 0.8) between the front leg joints and low (<0.2) between the rear leg joints. High genetic correlations between time points indicate that the trait can be considered the same at either time point, and low genetic correlations indicate that the trait at different time points should be considered as two separate traits. Minimal change in the front leg suggests conformation traits that remain between selection and post first parity, while larger changes in rear leg indicate that rear leg conformation traits should be evaluated at multiple time periods.
Extrinsic versus intrinsic hand muscle dominance in finger flexion.
Al-Sukaini, A; Singh, H P; Dias, J J
2016-05-01
This study aims to identify the patterns of dominance of extrinsic or intrinsic muscles in finger flexion during initiation of finger curl and mid-finger flexion. We recorded 82 hands of healthy individuals (18-74 years) while flexing their fingers and tracked the finger joint angles of the little finger using video motion tracking. A total of 57 hands (69.5%) were classified as extrinsic dominant, where the finger flexion was initiated and maintained at proximal interphalangeal and distal interphalangeal joints. A total of 25 (30.5%) were classified as intrinsic dominant, where the finger flexion was initiated and maintained at the metacarpophalangeal joint. The distribution of age, sex, dominance, handedness and body mass index was similar in the two groups. This knowledge may allow clinicians to develop more efficient rehabilitation regimes, since intrinsic dominant individuals would not initiate extrinsic muscle contraction till later in finger flexion, and might therefore be allowed limited early active motion. For extrinsic dominant individuals, by contrast, initial contraction of extrinsic muscles would place increased stress on the tendon repair site if early motion were permitted. © The Author(s) 2016.
Pourahmadi, Mohammad Reza; Taghipour, Morteza; Jannati, Elham; Mohseni-Bandpei, Mohammad Ali; Ebrahimi Takamjani, Ismail; Rajabzadeh, Fatemeh
2016-01-01
Measurement of lumbar spine range of motion (ROM) is often considered to be an essential component of lumbar spine physiotherapy and orthopedic assessment. The measurement can be carried out through various instruments such as inclinometers, goniometers, and etc. Recent smartphones have been equipped with accelerometers and magnetometers, which, through specific software applications (apps) can be used for inclinometric functions. The main purpose was to investigate the reliability and validity of an iPhone(®) app (TiltMeter(©) -advanced level and inclinometer) for measuring standing lumbar spine flexion-extension ROM in asymptomatic subjects. A cross-sectional study was carried out. This study was conducted in a physiotherapy clinic located at School of Rehabilitation Sciences, Iran University of Medical Science and Health Services, Tehran, Iran. A convenience sample of 30 asymptomatic adults (15 males; 15 females; age range = 18-55 years) was recruited between August 2015 and December 2015. Following a 2-minute warm-up, the subjects were asked to stand in a relaxed position and their skin was marked at the T12-L1 and S1-S2 spinal levels. From this position, they were asked to perform maximum lumbar flexion followed by maximum lumbar extension with their knees straight. Two blinded raters each used an inclinometer and the iPhone (®) app to measure lumbar spine flexion-extension ROM. A third rater read the measured angles. To calculate total lumbar spine flexion-extension ROM, the measurement from S1-S2 was subtracted from T12-L1. The second (2 hours later) and third (48 hours later) sessions were carried out in the same manner as the first session. All of the measurements were conducted 3 times and the mean value of 3 repetitions for each measurement was used for analysis. Intraclass correlation coefficient (ICC) models (3, k) and (2, k) were used to determine the intra-rater and inter-rater reliability, respectively. The Pearson correlation coefficients were used to establish concurrent validity of the iPhone(®) app. Furthermore, minimum detectable change at the 95% confidence level (MDC95) was computed as 1.96 × standard error of measurement × [Formula: see text]. Good to excellent intra-rater and inter-rater reliability were demonstrated for both the gravity-based inclinometer with ICC values of ≥0.84 and ≥0.77 and the iPhone(®) app with ICC values of ≥0.85 and ≥0.85, respectively. The MDC95 ranged from 5.82°to 8.18°for the intra-rater analysis and from 7.38°to 8.66° for the inter-rater analysis. The concurrent validity for flexion and extension between the 2 instruments was 0.85 and 0.91, respectively. The iPhone(®)app possesses good to excellent intra-rater and inter-rater reliability and concurrent validity. It seems that the iPhone(®) app can be used for the measurement of lumbar spine flexion-extension ROM. IIb.
NASA Astrophysics Data System (ADS)
Silva, Ana S.; Catarino, André; Correia, Miguel V.; Frazão, Orlando
2013-12-01
The work presented here describes the development and characterization of intensity fiber optic sensor integrated in a specifically designed piece of garment to measure elbow flexion. The sensing head is based on macrobending incorporated in the garment, and the increase of curvature number was studied in order to investigate which scheme provided a good result in terms of sensitivity and repeatability. Results showed the configuration that assured a higher sensitivity (0.644 dBm/deg) and better repeatability was the one with four loops. Ultimately, this sensor can be used for rehabilitation purposes to monitor human joint angles, namely, elbow flexion on stroke survivors while performing the reach functional task, which is the most common upper-limb human gesture.
Sacroiliac joint motion in patients with degenerative lumbar spine disorders.
Nagamoto, Yukitaka; Iwasaki, Motoki; Sakaura, Hironobu; Sugiura, Tsuyoshi; Fujimori, Takahito; Matsuo, Yohei; Kashii, Masafumi; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi
2015-08-01
OBJECT Usually additional anchors into the ilium are necessary in long fusion to the sacrum for degenerative lumbar spine disorders (DLSDs), especially for adult spine deformity. Although the use of anchors is becoming quite common, surgeons must always keep in mind that the sacroiliac (SI) joint is mobile and they should be aware of the kinematic properties of the SI joint in patients with DLSDs, including adult spinal deformity. No previous study has clarified in vivo kinematic changes in the SI joint with respect to patient age, sex, or parturition status or the presence of DLSDs. The authors conducted a study to clarify the mobility and kinematic characteristics of the SI joint in patients with DLSDs in comparison with healthy volunteers by using in vivo 3D motion analysis with voxel-based registration, a highly accurate, noninvasive method. METHODS Thirteen healthy volunteers (the control group) and 20 patients with DLSDs (the DLSD group) underwent low-dose 3D CT of the lumbar spine and pelvis in 3 positions (neutral, maximal trunk flexion, and maximal trunk extension). SI joint motion was calculated by computer processing of the CT images (voxel-based registration). 3D motion of the SI joint was expressed as both 6 df by Euler angles and translations on the coordinate system and a helical axis of rotation. The correlation between joint motion and the cross-sectional area of the trunk muscles was also investigated. RESULTS SI joint motion during trunk flexion-extension was minute in healthy volunteers. The mean rotation angles during trunk flexion were 0.07° around the x axis, -0.02° around the y axis, and 0.16° around the z axis. The mean rotation angles during trunk extension were 0.38° around the x axis, -0.08° around the y axis, and 0.08° around the z axis. During trunk flexion-extension, the largest amount of motion occurred around the x axis. In patients with DLSDs, the mean rotation angles during trunk flexion were 0.57° around the x axis, 0.01° around the y axis, and 0.19° around the z axis. The mean rotation angles during trunk extension were 0.68° around the x axis, -0.11° around the y axis, and 0.05° around the z axis. Joint motion in patients with DLSDs was significantly greater, with greater individual difference, than in healthy volunteers. Among patients with DLSDs, women had significantly more motion than men did during trunk extension. SI joint motion was significantly negatively correlated with the cross-sectional area of the trunk muscles during both flexion and extension of the trunk. CONCLUSIONS The authors elucidated the mobility and kinematic characteristics of the SI joint in patients with DLSDs compared with healthy volunteers for the first time. This information is useful for spine surgeons because of the recent increase in spinopelvic fusion for the treatment of DLSDs.
An implantable transducer for measuring tension in an anterior cruciate ligament graft.
Ventura, C P; Wolchok, J; Hull, M L; Howell, S M
1998-06-01
The goal of this study was to develop a new implantable transducer for measuring anterior cruciate ligament (ACL) graft tension postoperatively in patients who have undergone ACL reconstructive surgery. A unique approach was taken of integrating the transducer into a femoral fixation device. To devise a practical in vivo calibration protocol for the fixation device transducer (FDT), several hypotheses were investigated: (1) The use of a cable versus the actual graft as the means for applying load to the FDT during calibration has no significant effect on the accuracy of the FDT tension measurements; (2) the number of flexion angles at which the device is calibrated has no significant effect on the accuracy of the FDT measurements; (3) the friction between the graft and femoral tunnel has no significant effect on measurement accuracy. To provide data for testing these hypotheses, the FDT was first calibrated with both a cable and a graft over the full range of flexion. Then graft tension was measured simultaneously with both the FDT on the femoral side and load cells, which were connected to the graft on the tibial side, as five cadaver knees were loaded externally. Measurements were made with both standard and overdrilled tunnels. The error in the FDT tension measurements was the difference between the graft tension measured by the FDT and the load cells. Results of the statistical analyses showed that neither the means of applying the calibration load, the number of flexion angles used for calibration, nor the tunnel size had a significant effect on the accuracy of the FDT. Thus a cable may be used instead of the graft to transmit loads to the FDT during calibration, thus simplifying the procedure. Accurate calibration requires data from just three flexion angles of 0, 45, and 90 deg and a curve fit to obtain a calibration curve over a continuous range of flexion within the limits of this angle group. Since friction did not adversely affect the measurement accuracy of the FDT, the femoral tunnel can be drilled to match the diameter of the graft and does not need to be overdrilled. Following these procedures, the error in measuring graft tension with the FDT averages less than 10 percent relative to a full-scale load of 257 N.
IMU-Based Joint Angle Measurement for Gait Analysis
Seel, Thomas; Raisch, Jorg; Schauer, Thomas
2014-01-01
This contribution is concerned with joint angle calculation based on inertial measurement data in the context of human motion analysis. Unlike most robotic devices, the human body lacks even surfaces and right angles. Therefore, we focus on methods that avoid assuming certain orientations in which the sensors are mounted with respect to the body segments. After a review of available methods that may cope with this challenge, we present a set of new methods for: (1) joint axis and position identification; and (2) flexion/extension joint angle measurement. In particular, we propose methods that use only gyroscopes and accelerometers and, therefore, do not rely on a homogeneous magnetic field. We provide results from gait trials of a transfemoral amputee in which we compare the inertial measurement unit (IMU)-based methods to an optical 3D motion capture system. Unlike most authors, we place the optical markers on anatomical landmarks instead of attaching them to the IMUs. Root mean square errors of the knee flexion/extension angles are found to be less than 1° on the prosthesis and about 3° on the human leg. For the plantar/dorsiflexion of the ankle, both deviations are about 1°. PMID:24743160
Crenshaw, Jeremy R; Rosenblatt, Noah J; Hurt, Christopher P; Grabiner, Mark D
2012-01-03
This study evaluated the discriminant capability of stability measures, trunk kinematics, and step kinematics to classify successful and failed compensatory stepping responses. In addition, the shared variance between stability measures, step kinematics, and trunk kinematics is reported. The stability measures included the anteroposterior distance (d) between the body center of mass and the stepping limb toe, the margin of stability (MOS), as well as time-to-boundary considering velocity (TTB(v)), velocity and acceleration (TTB(a)), and MOS (TTB(MOS)). Kinematic measures included trunk flexion angle and angular velocity, step length, and the time after disturbance onset of recovery step completion. Fourteen young adults stood on a treadmill that delivered surface accelerations necessitating multiple forward compensatory steps. Thirteen subjects fell from an initial disturbance, but recovered from a second, identical disturbance. Trunk flexion velocity at completion of the first recovery step and trunk flexion angle at completion of the second step had the greatest overall classification of all measures (92.3%). TTB(v) and TTB(a) at completion of both steps had the greatest classification accuracy of all stability measures (80.8%). The length of the first recovery step (r ≤ 0.70) and trunk flexion angle at completion of the second recovery step (r ≤ -0.54) had the largest correlations with stability measures. Although TTB(v) and TTB(a) demonstrated somewhat smaller discriminant capabilities than trunk kinematics, the small correlations between these stability measures and trunk kinematics (|r| ≤ 0.52) suggest that they reflect two important, yet different, aspects of a compensatory stepping response. Copyright © 2011 Elsevier Ltd. All rights reserved.
Omorczyk, Jarosław; Nosiadek, Leszek; Ambroży, Tadeusz; Nosiadek, Andrzej
2015-01-01
The main aim of this study was to verify the usefulness of selected simple methods of recording and fast biomechanical analysis performed by judges of artistic gymnastics in assessing a gymnast's movement technique. The study participants comprised six artistic gymnastics judges, who assessed back handsprings using two methods: a real-time observation method and a frame-by-frame video analysis method. They also determined flexion angles of knee and hip joints using the computer program. In the case of the real-time observation method, the judges gave a total of 5.8 error points with an arithmetic mean of 0.16 points for the flexion of the knee joints. In the high-speed video analysis method, the total amounted to 8.6 error points and the mean value amounted to 0.24 error points. For the excessive flexion of hip joints, the sum of the error values was 2.2 error points and the arithmetic mean was 0.06 error points during real-time observation. The sum obtained using frame-by-frame analysis method equaled 10.8 and the mean equaled 0.30 error points. Error values obtained through the frame-by-frame video analysis of movement technique were higher than those obtained through the real-time observation method. The judges were able to indicate the number of the frame in which the maximal joint flexion occurred with good accuracy. Using the real-time observation method as well as the high-speed video analysis performed without determining the exact angle for assessing movement technique were found to be insufficient tools for improving the quality of judging.
Kim, Ki-Tack; Lee, Sang-Hun; Suk, Kyung-Soo; Lee, Jung-Hee; Jeong, Bi-O
2010-06-01
The purpose of this study was to analyze the biomechanical effects of three different constrained types of an artificial disc on the implanted and adjacent segments in the lumbar spine using a finite element model (FEM). The created intact model was validated by comparing the flexion-extension response without pre-load with the corresponding results obtained from the published experimental studies. The validated intact lumbar model was tested after implantation of three artificial discs at L4-5. Each implanted model was subjected to a combination of 400 N follower load and 5 Nm of flexion/extension moments. ABAQUS version 6.5 (ABAQUS Inc., Providence, RI, USA) and FEMAP version 8.20 (Electronic Data Systems Corp., Plano, TX, USA) were used for meshing and analysis of geometry of the intact and implanted models. Under the flexion load, the intersegmental rotation angles of all the implanted models were similar to that of the intact model, but under the extension load, the values were greater than that of the intact model. The facet contact loads of three implanted models were greater than the loads observed with the intact model. Under the flexion load, three types of the implanted model at the L4-5 level showed the intersegmental rotation angle similar to the one measured with the intact model. Under the extension load, all of the artificial disc implanted models demonstrated an increased extension rotational angle at the operated level (L4-5), resulting in an increase under the facet contact load when compared with the adjacent segments. The increased facet load may lead to facet degeneration.
Acute Effects of Hamstring Stretching on Sagittal Spinal Curvatures and Pelvic Tilt
López-Miñarro, Pedro A.; Muyor, José M.; Belmonte, Felipe; Alacid, Fernando
2012-01-01
The aim of this study was to determine acute effects of hamstring stretching in thoracic and lumbar spinal curvatures and pelvic tilt. Fifty-five adults (29.24 ± 7.41 years) were recruited for this study. Subjects performed a hamstring stretching protocol consisting of four exercises. The session consisted of 3 sets of each exercise and subjects held the position for 20 seconds with a 30-second rest period between sets and exercises. Thoracic and lumbar spinal angles and pelvic tilt were measured with a SpinalMouse in relaxed standing, sit-and-reach test and Macrae & Wright position. Hamstring extensibility was determined by active straight leg raise test and sit-and-reach score. All measures were performed before and immediately after the hamstring stretching protocol. Active straight leg raise angle and sitand-reach score significantly improved immediately after the stretching protocol (p<0.001). Greater anterior pelvic tilt (p<0.001) and lumbar flexion (p<0.05) and a smaller thoracic kyphosis in the sit-and-reach (p<0.001) were found after the stretching protocol. However, stretching produced no significant change on spinal curvatures or pelvic tilt in standing and maximal trunk flexion with knees flexed. In conclusion, static stretching of the hamstring is associated to an immediate change in the sagittal spinal curvatures and pelvic position when performing trunk flexion with knees extended, so that allowing for greater lumbar flexion and anterior pelvic tilt and lower thoracic kyphosis. Hamstring stretching is recommended prior to sport activities involving trunk flexion with the knees straight. PMID:23486214
Smith, Rose; Ford, Kevin R; Myer, Gregory D; Holleran, Adam; Treadway, Erin; Hewett, Timothy E
2007-01-01
Context: The recent increase in women's varsity soccer participation has been accompanied by a lower extremity injury rate that is 2 to 6 times that of their male counterparts. Objective: To define the differences between lower extremity biomechanics (knee abduction and knee flexion measures) and performance (maximal vertical jump height) between National Collegiate Athletic Association Division I and III female soccer athletes during a drop vertical jump. Design: Mixed 2 × 2 design. Setting: Research laboratory. Patients or Other Participants: Thirty-four female collegiate soccer players (Division I: n = 19; Division III: n = 15) participated in the study. The groups were similar in height and mass. Intervention(s): Each subject performed a maximal vertical jump, followed by 3 drop vertical jumps. Main Outcome Measure(s): Kinematics (knee abduction and flexion angles) and kinetics (knee abduction and flexion moments) were measured with a motion analysis system and 2 force platforms during the drop vertical jumps. Results: Knee abduction angular range of motion and knee abduction external moments were not different between groups (P > .05). However, Division I athletes demonstrated decreased knee flexion range of motion (P = .038) and greater peak external knee flexion moment (P = .009) compared with Division III athletes. Division I athletes demonstrated increased vertical jump height compared with Division III (P = .008). Conclusions: Division I athletes demonstrated different sagittal-plane mechanics than Division III athletes, which may facilitate improved performance. The similarities in anterior cruciate ligament injury risk factors (knee abduction torques and angles) may correlate with the consistent incidence of anterior cruciate ligament injury across divisions. PMID:18174935
Hosseini, Ali; Qi, Wei; Tsai, Tsung-Yuan; Liu, Yujie; Rubash, Harry; Li, Guoan
2014-01-01
Purpose The knowledge of the function of the collateral ligaments – i.e., superficial medial collateral ligament (sMCL), deep medial collateral ligament (dMCL) and lateral collateral ligament (LCL) – in the entire range of knee flexion is important for soft tissue balance during total knee arthroplasty. The objective of this study was to investigate the length changes of different portions (anterior, middle and posterior) of the sMCL, dMCL and LCL during in vivo weightbearing flexion from full extension to maximal knee flexion. Methods Using a dual fluoroscopic imaging system eight healthy knees were imaged while performing a lunge from full extension to maximal flexion. The length changes of each portion of the collateral ligaments were measured along the flexion path of the knee. Results All anterior portions of the collateral ligaments were shown to have increasing length with flexion except that of the sMCL which showed a reduction in length at high flexion. The middle portions showed minimal change in lengths except that of the sMCL which showed a consistent reduction in length with flexion. All posterior portions showed reduction in lengths with flexion. Conclusions These data indicated that every portion of the ligaments may play important roles in knee stability at different knee flexion range. The soft tissue releasing during TKA may need to consider the function of the ligament portions along the entire flexion path including maximum flexion. PMID:25239504
Riding position and lumbar spine angle in recreational cyclists: A pilot study
SCHULZ, SAMANTHA J.; GORDON, SUSAN J.
2010-01-01
This pilot study investigated the reliability of an inclinometer to assess lumbar spine angle in three different cycling positions, and explored the relationship between lumbar spine angle and riding position, anthropometry, bike measures and low back pain (LBP). Cyclists were recruited from two cycle clubs. Anthropometric variables and bike setup were measured before participants’ bikes were secured in a wind trainer. Cyclists then adopted three positions for riding, upright on the handlebars, on the brake levers and on the drops, according to a random allocation. The angle of the lumbar spine was measured; using an inclinometer, at zero minutes and after cyclists had completed 10 minutes of cycling. Intra-measurer reliability for inclinometer use to measure lumbar spine angle in each position was excellent (ICC=0.97). The angle of the lumbar spine changed significantly over 10 minutes in the brake position (p=0.004). Lumbar spine angle at 10 minutes was significantly different between the brake and drop positions (p=0.018, p<0.05), and between upright and drop positions (p=0.012, p<0.05). Lumbar spine angle was not related to anthropometric measures. The change in lumbar spine angle varied from one degree of extension to 12 degrees of flexion, with increased flexion occurring in 95% of trials. An inclinometer has excellent intra-measurer reliability to measure lumbar spine angle in cycling positions. Future research with a sample of 72 or more participants is required to determine if there is a significant relationship between LBP and lumbar spine angle in different cycling positions. PMID:27182345
Effects of Angle Variations in Suspension Push-up Exercise.
Gulmez, Irfan
2017-04-01
Gulmez, I. Effects of angle variations in suspension push-up exercise. J Strength Cond Res 31(4): 1017-1023, 2017-This study aimed to determine and compare the amount of loads on the TRX Suspension Trainer (TRX) straps and ground reaction forces at 4 different angles during TRX push-ups. Twenty-eight male (mean age, 24.1 ± 2.9 years; height, 179.4 ± 8.0 m; weight, 78.8 ± 9.8 kg) physical education and sports university students participated in this study. The subjects were tested at TRX angles (0, 15, 30, 45°) during the TRX push-ups. Force data were recorded by a force platform and load cells integrated into the TRX straps. The results show that as the TRX angle was reduced, the load applied to the TRX straps increased and simultaneously the load measured by the force platform decreased. This was true for both the elbow joint changing from flexion to extension and vice versa. When the TRX angle was set at 0° and subjects' elbows were at extension during TRX push-up, 50.4% of the subjects' body weight, and when the elbows were at flexion, 75.3% of the body weight was registered by the sensors on the TRX straps. The results of this study can be used in the calculation of the training load and volume (resistance training programming) during TRX push-up exercises at varying angles.
Isometric elbow extensors strength in supine- and prone-lying positions.
Abdelzaher, Ibrahim E; Ababneh, Anas F; Alzyoud, Jehad M
2013-01-01
The purpose of this study was to compare isometric strength of elbow extensors measured in supine- and prone-lying positions at elbow flexion angles of 45 and 90 degrees. Twenty-two male subjects under single-blind procedures participated in the study. Each subject participated in both supine-lying and prone-lying measuring protocols. Calibrated cable tensiometer was used to measure isometric strength of the right elbow extensors and a biofeedback electromyography was used to assure no substitution movements from shoulder girdle muscles. The mean values of isometric strength of elbow extensors measured from supine-lying position at elbow flexion angles of 45 and 90 degrees were 11.1 ± 4.2 kg and 13.1 ± 4.6 kg, while those measured from prone-lying position were 9.9 ± 3.6 kg and 12 ± 4.2 kg, respectively. There is statistical significant difference between the isometric strength of elbow extensors measured from supine-lying position at elbow flexion angles of 45 and 90 degrees compared to that measured from prone-lying position (p < 0.05). The results suggest that in manual muscle testing starting position can affect the isometric strength of elbow extensors since supine-lying starting position is better than prone-lying starting position.
EMG and tibial shock upon the first attempt at barefoot running.
Olin, Evan D; Gutierrez, Gregory M
2013-04-01
As a potential means to decrease their risk of injury, many runners are transitioning into barefoot running. Habitually shod runners tend to heel-strike (SHS), landing on their heel first, while barefoot runners tend to mid-foot or toe-strike (BTS), landing flat-footed or on the ball of their foot before bringing down the rest of the foot including the heel. This study compared muscle activity, tibial shock, and knee flexion angle in subjects between shod and barefoot conditions. Eighteen habitually SHS recreational runners ran for 3 separate 7-minute trials, including SHS, barefoot heel-strike (BHS), and BTS conditions. EMG, tibial shock, and knee flexion angle were monitored using bipolar surface electrodes, an accelerometer, and an electrogoniometer, respectively. A one-way MANOVA for repeated measures was conducted and several significant changes were noted between SHS and BTS, including significant increases in average EMG of the medial gastrocnemius (p=.05), average and peak tibial shock (p<.01), and the minimum knee flexion angle (p<.01). Based on our data, the initial change in mechanics may have detrimental effects on the runner. While it has been argued that BTS running may ultimately be less injurious, these data indicate that habitually SHS runners who choose to transition into a BTS technique must undertake the process cautiously. Copyright © 2012 Elsevier B.V. All rights reserved.
Welch, Tyler; Keller, Thomas; Maldonado, Ruben; Metzger, Melodie; Mohr, Karen; Kvitne, Ronald
2017-12-01
The natural history of posterior cruciate ligament (PCL) deficiency includes the development of arthrosis in the patellofemoral joint (PFJ). The purpose of this biomechanical study was to evaluate the hypothesis that dynamic bracing reduces PFJ pressures in PCL- and combined PCL/posterolateral corner (PLC)-deficient knees. Controlled Laboratory Study. Eight fresh frozen cadaveric knees with intact cruciate and collateral ligaments were included. PFJ pressures and force were measured using a pressure mapping system via a lateral arthrotomy at knee flexion angles of 30°, 60°, 90°, and 120° in intact, PCL-deficient, and PCL/PLC-deficient knees under a combined quadriceps/hamstrings load of 400 N/200 N. Testing was then repeated in PCL- and PCL/PLC-deficient knees after application of a dynamic PCL brace. Application of a dynamic PCL brace led to a reduction in peak PFJ pressures in PCL-deficient knees. In addition, the brace led to a significant reduction in peak pressures in PCL/PLC-deficient knees at 60°, 90°, and 120° of flexion. Application of the dynamic brace also led to a reduction in total PFJ force across all flexion angles for both PCL- and PCL/PLC-deficient knees. Dynamic bracing reduces PFJ pressures in PCL- and combined PCL/PLC-deficient knees, particularly at high degrees of knee flexion.
Chon, Jegyun; Shin, Sangyeop; Jang, Gunil; Jeon, Taehyeon
2016-01-01
Background We investigated the causes of impingement between the patella bone and the bearing post during high flexion in cruciate-substituting total knee arthroplasty and proposed a treatment strategy. Methods This prospective cohort study included 218 cases that had undergone cruciate-substituting total knee arthroplasty from February 2014 to January 2015; a single surgeon performed the operation using the same method without patellar resurfacing in all patients. Results In these patients, the occurrence of impingement was determined by performing more than 120° high knee flexion after inserting a bearing perioperatively. The incidence of impingement was significantly associated with bearing design, femoral implant size, patella bone length, and patella inferior pole angle (p < 0.05). The impingement was resolved by resection of the lower articular side of the patella bone. Conclusions In the cruciate-substituting high-flexion total knee arthroplasty, impingement between the patella bone and bearing post was more common in patients with mobile bearing, small-size femoral component, and a long patella or a large inferior pole angle. In cases of intraoperative impingement between the patella bone and the bearing post, resection in the lower portion of the patella prevented impingement of the bearing with soft tissue or the patella by widening the space between the patella and the bearing post, which in turn prevented postoperative reduction in range of motion. PMID:27247740
Chon, Jegyun; Lee, Bongju; Shin, Sangyeop; Jang, Gunil; Jeon, Taehyeon
2016-06-01
We investigated the causes of impingement between the patella bone and the bearing post during high flexion in cruciate-substituting total knee arthroplasty and proposed a treatment strategy. This prospective cohort study included 218 cases that had undergone cruciate-substituting total knee arthroplasty from February 2014 to January 2015; a single surgeon performed the operation using the same method without patellar resurfacing in all patients. In these patients, the occurrence of impingement was determined by performing more than 120° high knee flexion after inserting a bearing perioperatively. The incidence of impingement was significantly associated with bearing design, femoral implant size, patella bone length, and patella inferior pole angle (p < 0.05). The impingement was resolved by resection of the lower articular side of the patella bone. In the cruciate-substituting high-flexion total knee arthroplasty, impingement between the patella bone and bearing post was more common in patients with mobile bearing, small-size femoral component, and a long patella or a large inferior pole angle. In cases of intraoperative impingement between the patella bone and the bearing post, resection in the lower portion of the patella prevented impingement of the bearing with soft tissue or the patella by widening the space between the patella and the bearing post, which in turn prevented postoperative reduction in range of motion.
Ergonomic strategies to improve radiographers' posture during mammography activities.
Cernean, Nicolai; Serranheira, Florentino; Gonçalves, Pedro; Sá Dos Reis, Cláudia
2017-08-01
To identify alternatives for radiographers' postures while performing mammography that can contribute to reduce the risk of work-related musculoskeletal disorders (WRMSDs). Radiographers' postures to positioning craniocaudal (CC) and mediolateral oblique (MLO) views were simulated without any intervention for three scenarios: radiographer/patient with similar statures, radiographer smaller than patient and radiographer taller than patient. Actions were taken to modify the postures: seated radiographer; patient on a step; seated patient; radiographer on a step. All the postures were analysed using kinovea 0.8.15 software and the angles were measured twice and classified according to European standard EN1005-4: 2005. The non-acceptable angles were measured mainly during MLO positioning when radiographer was taller than the patient: 139° and 120° for arm-flexion and abduction, 72° for trunk and -24° for head/neck-flexion. The introduction of alternative postures (radiographer seated), allowed improvements in posture (60° and 99° for arm flexion and abduction, 14° for trunk and 0° for head/neck flexion), being classified as acceptable. The alternative postures simulated have the potential to reduce the risk of developing WRMSDs when radiographers and patients have different statures. • Radiographers' postures in mammography can contribute to work-related musculoskeletal disorders • Non-acceptable posture was identified for MLO breast positioning (radiographer taller than patient) • Adapting posture to patient biotype reduces the WRMSD risk for radiographers.
Impact of Isometric Contraction of Anterior Cervical Muscles on Cervical Lordosis.
Fedorchuk, Curtis A; McCoy, Matthew; Lightstone, Douglas F; Bak, David A; Moser, Jacque; Kubricht, Brett; Packer, John; Walton, Dustin; Binongo, Jose
2016-09-01
This study investigates the impact of isometric contraction of anterior cervical muscles on cervical lordosis. 29 volunteers were randomly assigned to an anterior head translation (n=15) or anterior head flexion (n=14) group. Resting neutral lateral cervical x-rays were compared to x-rays of sustained isometric contraction of the anterior cervical muscles producing anterior head translation or anterior head flexion. Paired sample t-tests indicate no significant difference between pre and post anterior head translation or anterior head flexion. Analysis of variance suggests that gender and peak force were not associated with change in cervical lordosis. Chamberlain's to atlas plane line angle difference was significantly associated with cervical lordosis difference during anterior head translation (p=0.01). This study shows no evidence that hypertonicity, as seen in muscle spasms, of the muscles responsible for anterior head translation and anterior head flexion have a significant impact on cervical lordosis.
Shoulder internal rotation elbow flexion test for diagnosing cubital tunnel syndrome.
Ochi, Kensuke; Horiuchi, Yukio; Tanabe, Aya; Waseda, Makoto; Kaneko, Yasuhito; Koyanagi, Takahiro
2012-06-01
Shoulder internal rotation enhances symptom provocation attributed to cubital tunnel syndrome. We present a modified elbow flexion test--the shoulder internal rotation elbow flexion test--for diagnosing cubital tunnel syndrome. Fifty-five ulnar nerves in cubital tunnel syndrome patients and 123 ulnar nerves in controls were examined with 5 seconds each of elbow flexion, shoulder internal rotation, and shoulder internal rotation elbow flexion tests before and after treatment (surgery in 18; conservative in others). For the shoulder internal rotation elbow flexion test position, 90° abduction, maximum internal rotation, and 10° flexion of the shoulder were combined with the elbow flexion test position. The test was considered positive if any symptom for cubital tunnel syndrome developed <5 seconds. Influence of the shoulder internal rotation elbow flexion test was evaluated by nerve conduction studies in 10 cubital tunnel syndrome nerves and 7 control nerves. The sensitivities/specificities of the 5-second elbow flexion, shoulder internal rotation, and shoulder internal rotation elbow flexion tests were 25%/100%, 58%/100%, and 87%/98%, respectively. Sensitivity differences between the shoulder internal rotation elbow flexion test and the other two tests were significant. Shoulder internal rotation elbow flexion test results and cubital tunnel syndrome symptoms were significantly correlated. Influence of the shoulder internal rotation elbow flexion test on the ulnar nerve was seen in 8 of 10 cubital tunnel syndrome nerves but not in controls. The 5-second shoulder internal rotation elbow flexion test is specific, easy and quick provocative test for diagnosing cubital tunnel syndrome. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Lower-extremity biomechanics during forward and lateral stepping activities in older adults
Wang, Man-Ying; Flanagan, Sean; Song, Joo-Eun; Greendale, Gail A.; Salem, George J.
2012-01-01
Objective To characterize the lower-extremity biomechanics associated with stepping activities in older adults. Design Repeated-measures comparison of kinematics and kinetics associated with forward step-up and lateral step-up activities. Background Biomechanical analysis may be used to assess the effectiveness of various ‘in-home activities’ in targeting appropriate muscle groups and preserving functional strength and power in elders. Methods Data were analyzed from 21 participants (mean 74.7 yr (standard deviation, 4.4 yr)) who performed the forward and lateral step-up activities while instrumented for biomechanical analysis. Motion analysis equipment, inverse dynamics equations, and repeated measures anovas were used to contrast the maximum joint angles, peak net joint moments, angular impulse, work, and power associated with the activities. Results The lateral step-up resulted in greater maximum knee flexion (P < 0.001) and ankle dorsiflexion angles (P < 0.01). Peak joint moments were similar between exercises. The forward step-up generated greater peak hip power (P < 0.05) and total work (P < 0.001); whereas, the lateral step-up generated greater impulse (P < 0.05), work (P < 0.01), and power (P < 0.05) at the knee and ankle. Conclusions In older adults, the forward step-up places greater demand on the hip extensors, while lateral step-up places greater demand on the knee extensors and ankle plantar flexors. PMID:12620784
Fan, Dapeng; Wang, Wei; Hildebrand, Kevin A; Fan, Cun-Yi
2016-09-09
With the exception of normal anatomic changes in the medial collateral ligament and radial head, other factors related to carrying angle changes have not been systematically studied. We reviewed patients who underwent open arthrolysis of the elbow, and evaluated if open arthrolysis could change carrying angle. We then identified factors associated with carrying angle changes. Fifty patients with a minimum of 24 months of follow-up after open arthrolysis were evaluated retrospectively. Preoperative and postoperative carrying angles were compared. The carrying angles of 36 elbows in 36 patients were unchanged after surgery (Group A), while the carrying angles of 14 elbows in 14 patients increased postoperatively (Group B). In Group A, mean postoperative extension and flexion were 7° (range 0-24°) and 125° (range 10-135°) respectively, while mean postoperative pronation and supination were 60° (range 50-80°) and 65° (range 30-85°), respectively. In Group B, mean postoperative extension and flexion were 25° (range 0-40°) and 128° (range 60-138°), while mean postoperative pronation and supination were 65° (range 45-85°) and 60° (range 45-75°), respectively. No significant difference in range of motion and Mayo Elbow Performance Score was observed between the two groups. During open arthrolysis, humeral trochlea debridement and techniques for improving forearm rotation could increase carrying angle. However, this had no impact on elbow functional recovery.
Quadricep and hamstring activation during drop jumps with changes in drop height.
Peng, Hsien-Te; Kernozek, Thomas W; Song, Chen-Yi
2011-08-01
Compare the muscle activation patterns of the quadricep-hamstring during drop jumps with increasing demands of drop heights. Observational. University biomechanics laboratory. Fifteen male and eight female college physical education students. Electromyographic activity of the rectus femoris (RF) and biceps femoris (BF) during the landing and takeoff phase of drop jumps from 20 to 60-cm heights. The ground contact time, vertical ground reaction force (vGRF), knee flexion angle during ground contact, and jump height after takeoff were also analyzed. The activation of RF was higher in the drop jump from 60-cm than that from 20- and 30-cm (comparing 107.0 ± 45.9 to 82.3 ± 30.8 and 88.9 ± 38.9 %MVIC, P<.05) during the landing phase. Activation of BF remained similar across all drop heights. Drop jump from 60-cm resulted in greater contact time during takeoff phase and peak vGRF, and resulted in greater maximum knee flexion but straighter knee at ground contact than from lower drop heights. At drop height of 60-cm, the altered knee muscular activation and movement patterns may diminish the effectiveness of plyometric training and increase the potential injury risk of knee. Copyright © 2010 Elsevier Ltd. All rights reserved.
Effect of Different Levels of Localized Muscle Fatigue on Knee Position Sense
Gear, William S.
2011-01-01
There is little information available regarding how proprioceptive abilities decline as the amount of exertion increases during exercise. The purpose of this study was to determine the role of different levels of fatigue on knee joint position sense. A repeated measures design was used to examine changes in active joint reposition sense (AJRS) prior to and following three levels of fatigue. Eighteen participants performed knee extension and flexion isokinetic exercise until torque output was 90%, 70%, or 50% of the peak hamstring torque for three consecutive repetitions. Active joint reposition sense at 15, 30, or 45 degrees was tested following the isokinetic exercise session. Following testing of the first independent measure, participants were given a 20 minute rest period. Testing procedures were repeated for two more exercise sessions following the other levels of fatigue. Testing of each AJRS test angle was conducted on three separate days with 48 hours between test days. Significant main effect for fatigue was indicated (p = 0.001). Pairwise comparisons indicated a significant difference between the pre-test and following 90% of peak hamstring torque (p = 0.02) and between the pre-test and following 50% of peak hamstring torque (p = 0.02). Fatigue has long been theorized to be a contributing factor in decreased proprioceptive acuity, and therefore a contributing factor to joint injury. The findings of the present study indicate that fatigue may have an effect on proprioception following mild and maximum fatigue. Key points A repeated measures design was used to examine the effect of different levels of fatigue on active joint reposition sense (AJRS) of the knee at joint angles of 15°, 30° and 45° of flexion. A statistically significant main effect for fatigue was found, specifically between no fatigue and mild fatigue and no fatigue and maximum fatigue. A statistically significant interaction effect between AJRS and fatigue was not found. Secondary analysis of the results indicated a potential plateau effect of AJRS as fatigue continues to increase. Further investigation of the effect of increasing levels of fatigue on proprioception is warranted. PMID:24149565
Effect of different levels of localized muscle fatigue on knee position sense.
Gear, William S
2011-01-01
There is little information available regarding how proprioceptive abilities decline as the amount of exertion increases during exercise. The purpose of this study was to determine the role of different levels of fatigue on knee joint position sense. A repeated measures design was used to examine changes in active joint reposition sense (AJRS) prior to and following three levels of fatigue. Eighteen participants performed knee extension and flexion isokinetic exercise until torque output was 90%, 70%, or 50% of the peak hamstring torque for three consecutive repetitions. Active joint reposition sense at 15, 30, or 45 degrees was tested following the isokinetic exercise session. Following testing of the first independent measure, participants were given a 20 minute rest period. Testing procedures were repeated for two more exercise sessions following the other levels of fatigue. Testing of each AJRS test angle was conducted on three separate days with 48 hours between test days. Significant main effect for fatigue was indicated (p = 0.001). Pairwise comparisons indicated a significant difference between the pre-test and following 90% of peak hamstring torque (p = 0.02) and between the pre-test and following 50% of peak hamstring torque (p = 0.02). Fatigue has long been theorized to be a contributing factor in decreased proprioceptive acuity, and therefore a contributing factor to joint injury. The findings of the present study indicate that fatigue may have an effect on proprioception following mild and maximum fatigue. Key pointsA repeated measures design was used to examine the effect of different levels of fatigue on active joint reposition sense (AJRS) of the knee at joint angles of 15°, 30° and 45° of flexion.A statistically significant main effect for fatigue was found, specifically between no fatigue and mild fatigue and no fatigue and maximum fatigue.A statistically significant interaction effect between AJRS and fatigue was not found.Secondary analysis of the results indicated a potential plateau effect of AJRS as fatigue continues to increase.Further investigation of the effect of increasing levels of fatigue on proprioception is warranted.
Influence of variable resistance loading on subsequent free weight maximal back squat performance.
Mina, Minas A; Blazevich, Anthony J; Giakas, Giannis; Kay, Anthony D
2014-10-01
The purpose of the study was to determine the potentiating effects of variable resistance (VR) exercise during a warm-up on subsequent free-weight resistance (FWR) maximal squat performance. In the first session, 16 recreationally active men (age = 26.0 ± 7.8 years; height = 1.7 ± 0.2 m; mass = 82.6 ± 12.7 kg) were familiarized with the experimental protocols and tested for 1 repetition maximum (1RM) squat lift. The subjects then visited the laboratory on 2 further occasions under either control or experimental conditions. During these conditions, 2 sets of 3 repetitions of either FWR (control) or VR (experimental) squat lifts at 85% of 1RM were performed; during the experimental condition, 35% of the load was generated from band tension. After a 5-minute rest, 1RM, 3D knee joint kinematics, and vastus medialis, vastus lateralis, rectus femoris, and semitendinosus electromyogram (EMG) signals were recorded simultaneously. No subject increased 1RM after FWR, however, 13 of 16 (81%) subjects increased 1RM after VR (mean = 7.7%; p < 0.01). Lower peak and mean eccentric (16-19%; p ≤ 0.05) and concentric (12-21%; p ≤ 0.05) knee angular velocities were observed during the 1RM following VR when compared with FWR, however, no differences in knee flexion angle (1.8°; p > 0.05) or EMG amplitudes (mean = 5.9%; p > 0.05) occurred. Preconditioning using VR significantly increased 1RM without detectable changes in knee extensor muscle activity or knee flexion angle, although eccentric and concentric velocities were reduced. Thus, VR seems to potentiate the neuromuscular system to enhance subsequent maximal lifting performance. Athletes could thus use VR during warm-up routines to maximize squat performance.
Hip-Extensor Strength, Trunk Posture, and Use of the Knee-Extensor Muscles During Running.
Teng, Hsiang-Ling; Powers, Christopher M
2016-07-01
Diminished hip-muscle performance has been proposed to contribute to various knee injuries. To determine the association between hip-extensor muscle strength and sagittal-plane trunk posture and the relationships among hip-extensor muscle strength and hip- and knee-extensor work during running. Descriptive laboratory study. Musculoskeletal biomechanical laboratory. A total of 40 asymptomatic recreational runners, 20 men (age = 27.1 ± 7.0 years, height = 1.74 ± 0.69 m, mass = 71.1 ± 8.2 kg) and 20 women (age = 26.2 ± 5.8 years, height = 1.65 ± 0.74 m, mass = 60.6 ± 6.6 kg), participated. Maximum isometric strength of the hip extensors was assessed using a dynamometer. Sagittal-plane trunk posture (calculated relative to the global vertical axis) and hip- and knee-extensor work (sum of energy absorption and generation) during the stance phase of running were quantified while participants ran over ground at a controlled speed of 3.4 m/s. We used Pearson product moment correlations to examine the relationships among hip-extensor strength, mean sagittal-plane trunk-flexion angle, hip-extensor work, and knee-extensor work. Hip-extensor strength was correlated positively with trunk-flexion angle (r = 0.55, P < .001) and hip-extensor work (r = 0.46, P = .003). It was correlated inversely with knee-extensor work (r = -0.39, P = .01). All the correlations remained after adjusting for sex. Our findings suggest that runners with hip-extensor weakness used a more upright trunk posture. This strategy led to an overreliance on the knee extensors and may contribute to overuse running injuries at the knee.
Antagonist muscle co-contraction during a double-leg landing maneuver at two heights.
Mokhtarzadeh, Hossein; Yeow, Chen Hua; Goh, James Cho Hong; Oetomo, Denny; Ewing, Katie; Lee, Peter Vee Sin
2017-10-01
Knee injuries are common during landing activities. Greater landing height increases peak ground reaction forces (GRFs) and loading at the knee joint. As major muscles to stabilize the knee joint, Quadriceps and Hamstring muscles provide internal forces to attenuate the excessive GRF. Despite the number of investigations on the importance of muscle function during landing, the role of landing height on these muscles forces using modeling during landing is not fully investigated. Participant-specific musculoskeletal models were developed using experimental motion analysis data consisting of anatomic joint motions and GRF from eight male participants performing double-leg drop landing from 30 and 60 cm. Muscle forces were calculated in OpenSim and their differences were analyzed at the instances of high risk during landing i.e. peak GRF for both heights. The maximum knee flexion angle and moments were found significantly higher from a double-leg landing at 60 cm compared to 30 cm. The results showed elevated GRF, and mean muscle forces during landing. At peak GRF, only quadriceps showed significantly greater forces at 60 cm. Hamstring muscle forces did not significantly change at 60 cm compared to 30 cm. Quadriceps and hamstring muscle forces changed at different heights. Since hamstring forces were similar in both landing heights, this could lead to an imbalance between the antagonist muscles, potentially placing the knee at risk of injury if combined with small flexion angles that was not observed at peak GRF in our study. Thus, enhanced neuromuscular training programs strengthening the hamstrings may be required to address this imbalance. These findings may contribute to enhance neuromuscular training programs to prevent knee injuries during landing.
Hip-Extensor Strength, Trunk Posture, and Use of the Knee-Extensor Muscles During Running
Teng, Hsiang-Ling; Powers, Christopher M.
2016-01-01
Context: Diminished hip-muscle performance has been proposed to contribute to various knee injuries. Objective: To determine the association between hip-extensor muscle strength and sagittal-plane trunk posture and the relationships among hip-extensor muscle strength and hip- and knee-extensor work during running. Design: Descriptive laboratory study. Setting: Musculoskeletal biomechanical laboratory. Patients or Other Participants: A total of 40 asymptomatic recreational runners, 20 men (age = 27.1 ± 7.0 years, height = 1.74 ± 0.69 m, mass = 71.1 ± 8.2 kg) and 20 women (age = 26.2 ± 5.8 years, height = 1.65 ± 0.74 m, mass = 60.6 ± 6.6 kg), participated. Main Outcome Measure(s): Maximum isometric strength of the hip extensors was assessed using a dynamometer. Sagittal-plane trunk posture (calculated relative to the global vertical axis) and hip- and knee-extensor work (sum of energy absorption and generation) during the stance phase of running were quantified while participants ran over ground at a controlled speed of 3.4 m/s. We used Pearson product moment correlations to examine the relationships among hip-extensor strength, mean sagittal-plane trunk-flexion angle, hip-extensor work, and knee-extensor work. Results: Hip-extensor strength was correlated positively with trunk-flexion angle (r = 0.55, P < .001) and hip-extensor work (r = 0.46, P = .003). It was correlated inversely with knee-extensor work (r = −0.39, P = .01). All the correlations remained after adjusting for sex. Conclusions: Our findings suggest that runners with hip-extensor weakness used a more upright trunk posture. This strategy led to an overreliance on the knee extensors and may contribute to overuse running injuries at the knee. PMID:27513169
Liu, Ping; Wang, Jianquan; Xu, Yan; Ao, Yingfang
2015-04-01
The aim of this study was to determine the in situ forces and length patterns of the fibular collateral ligament (FCL) and kinematics of the knee under various loading conditions. Six fresh-frozen cadaveric knees were used (mean age 46 ± 14.4 years; range 20-58). In situ forces and length patterns of FCL and kinematics of the knee were determined under the following loading conditions using a robotic/universal force-moment sensor testing system: no rotation, varus (10 Nm), external rotation (5 Nm), and internal rotation (5 Nm) at 0°, 15°, 30°, 60º, 90°, and 120° of flexion, respectively. Under no rotation loading, the distances between the centres of the FCL attachments decreased as the knee flexed. Under varus loading, the force in FCL peaked at 15° of flexion and decreased with further knee flexion, while distances remained nearly constant and the varus rotation increased with knee flexion. Using external rotation, the force in the FCL also peaked at 15° flexion and decreased with further knee flexion, the distances decreased with flexion, and external rotation increased with knee flexion. Using internal rotation load, the force in the FCL was relatively small across all knee flexion angles, and the distances decreased with flexion; the amount of internal rotation was fairly constant. FCL has a primary role in preventing varus and external rotation at 15° of flexion. The FCL does not perform isometrically following knee flexion during neutral rotation, and tibia rotation has significant effects on the kinematics of the FCL. Varus and external rotation laxity increased following knee flexion. By providing more realistic data about the function and length patterns of the FCL and the kinematics of the intact knee, improved reconstruction and rehabilitation protocols can be developed.
Takeuchi, Kazunari; Yokoyama, Toru; Ono, Atsushi; Numasawa, Takuya; Wada, Kanichiro; Itabashi, Taito; Toh, Satoshi
2008-03-01
Although difficulties with neck mobility often interfere with patients' activities of daily living (ADL) after cervical laminoplasty, there was no detailed study on the relation between the limitations of ADL accompanying postoperative reduced neck mobility and the cervical posterior approach. The aim of this study was to compare retrospectively the frequency of limitations of ADL accompanying neck mobility after laminoplasty preserving the semispinalis cervicis inserted into the C2 spinous process with that after laminoplasty reattaching the muscle to C2. Forty-nine patients after C4-C7 laminoplasty with C3 laminectomy preserving the semispinalis cervicis inserted into C2 (Group A) and 24 patients after C3-C7 laminoplasty reattaching the muscle (Group B) were evaluated. The frequency of postoperative limitations of ADL accompanying each of three neck movements of extension, flexion and rotation were investigated. The postoperative O-C7 angles at extension and flexion was measured on lateral extension and flexion radiographs of the cervical spine, respectively. The postoperative cervical range of motion in rotation was measured in the cranial view using a digital camera. Frequency of limitations of ADL accompanying extension was lower (P = 0.037) in Group A (2%) than in Group B (17%). Frequency of limitations of ADL accompanying flexion was similar in Group A (8%) and Group B (4%). Frequency of limitations of ADL accompanying rotation was lower (P = 0.031) in Group A (12%) than in Group B (33%). Average O-C7 angle at extension was significantly larger (P = 0.002) in Group A (147 degrees ) than in Group B (136 degrees ). Average O-C7 angle at flexion was similar in Group A (93 degrees ) and Group B (91 degrees ). Average range of motion in rotation was significantly larger (P = 0.004) in Group A (110 degrees ) than in Group B (91 degrees ). This retrospective study suggested that the frequency of limitations of ADL accompanying neck extension or rotation was lower after laminoplasty preserving the semispinalis cervicis inserted into C2 than after laminoplasty reattaching the muscle.
Drews, Björn Holger; Seitz, Andreas Martin; Huth, Jochen; Bauer, Gerhard; Ignatius, Anita; Dürselen, Lutz
2017-05-01
The purpose of this study was to investigate whether an anterior cruciate ligament (ACL) double-bundle reconstruction with one tibial tunnel displays the same in vitro stability as a conventional double-bundle reconstruction with two tibial tunnels when using the same tensioning protocol. In 11 fresh-frozen cadaveric knees, ACL double-bundle reconstruction with one and two tibial tunnels was performed. The two grafts were tightened using 80 N in different flexion angles (anteromedial-bundle at 60° and posterolateral-bundle at 15°). Anterior tibial translation (134 N) and translation with combined rotatory and valgus loads (10 Nm valgus stress and 4 Nm internal tibial torque) were determined at 0°, 30°, 60° and 90° flexion. Measurements were taken in intact ACL, resected ACL, three-tunnel reconstruction and four-tunnel reconstruction. Additionally, the tension on the grafts was determined. Student's t test was performed for statistical analysis of the related samples. Significance was set at p < 0.017 according to Bonferroni correction. The two reconstructive techniques displayed no significant differences in comparison with the intact ACL in anterior tibial translation at 0°, 60° and 90° of flexion. The same results were obtained for the anterior tibial translation with a combined rotatory load at 60° and 90°. When directly comparing both reconstructive techniques, there were no significant differences for the anterior tibial translation and combined rotatory load at all flexion angles. The measured tension on grafts displayed similar load sharing between both bundles. Except at full extension, both grafts displayed a significantly different tension increase under anterior tibial translation for both techniques (p = 0.0086). Tightening both bundles in ACL double-bundle reconstruction with one or two tibial tunnels in different flexion angles achieved comparable restoration of stability, although there was different load sharing on the bundles. With regard to individualized ACL reconstruction, the double-bundle technique with one tibial tunnel offers a possibility to address small tibial insertion sites without compromising the advantages of a double-bundle procedure.
Lopes, Thiago Jambo Alves; Simic, Milena; Myer, Gregory D; Ford, Kevin R; Hewett, Timothy E; Pappas, Evangelos
2018-05-01
Anterior cruciate ligament (ACL) tear is a common injury in sports and often occurs during landing from a jump. To synthesize the evidence on the effects of injury prevention programs (IPPs) on landing biomechanics as they relate to the ligament, quadriceps, trunk, and leg dominance theories associated with ACL injury risk. Meta-analysis. Six electronic databases were searched for studies that investigated the effect of IPPs on landing task biomechanics. Prospective studies that reported landing biomechanics at baseline and post-IPP were included. Results from trunk, hip, and knee kinematics and kinetics related to the ACL injury theories were extracted, and meta-analyses were performed when possible. The criteria were met by 28 studies with a total of 466 participants. Most studies evaluated young females, bilateral landing tasks, and recreational athletes, while most variables were related to the ligament and quadriceps dominance theories. An important predictor of ACL injury, peak knee abduction moment, decreased ( P = .01) after the IPPs while other variables related to the ligament dominance theory did not change. Regarding the quadriceps dominance theory, after the IPPs, angles of hip flexion at initial contact ( P = .009), peak hip flexion ( P = .002), and peak knee flexion ( P = .007) increased, while knee flexion at initial contact did not change ( P = .18). Moreover, peak knee flexion moment decreased ( P = .005) and peak vertical ground-reaction force did not change ( P = .10). The exercises used in IPPs might have the potential to improve landing task biomechanics related to the quadriceps dominance theory, especially increasing peak knee and hip flexion angles. Importantly, peak knee abduction moment decreased, which indicates that IPPs influence a desired movement strategy to help athletes overcome dangerous ligament dominance loads arising from lack of frontal plane control during dynamic tasks. The lack of findings for some biomechanical variables suggests that future IPPs may be enhanced by targeting participants' baseline profile deficits, highlighting the need to deliver an individualized and task-specific IPP.
Liao, Chun-De; Huang, Yi-Ching; Lin, Li-Fong; Chiu, Yen-Shuo; Tsai, Jui-Chen; Chen, Chun-Lung; Liou, Tsan-Hon
2016-08-01
This study evaluated the effects of continuous passive motion (CPM) on accelerated flexion after total knee arthroplasty (TKA) and whether CPM application measures (i.e. initial angle and daily increment) are associated with functional outcomes. A retrospective investigation was conducted at the rehabilitation centre of a university-based teaching hospital. Patients who received CPM therapy immediately after TKA surgery were categorized into rapid-, normal-, and slow-progress groups according to their response to CPM during their acute inpatient stay. Knee pain, passive knee flexion, and knee function-measured using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC)-were assessed preoperatively at discharge and at 3- and 6-month outpatient follow-up visits. A total of 354 patients were followed for 6 months after inpatient-stay discharge. The patients in the rapid-progress group (n = 119) exhibited significantly greater knee flexions than those in the slow-progress group did (n = 103) at the 3-month follow-up [mean difference (MD) = 10.3°, 95 % confidence interval (CI) 4.3°-16.3°, p < 0.001] and 6-month follow-up (MD = 10.9°, 95 % CI 6.3°-15.6°, p < 0.001). Significant WOMAC score differences between the rapid- and slow-progress groups were observed at the 3-month follow-up (MD = 7.2, 95 % CI 5.4-9.1, p < 0.001) and 6-month follow-up (MD = 16.1, 95 % CI 13.4-18.7, p < 0.001). CPM initial angles and rapid progress significantly predicted short- and long-term outcomes in knee flexion and WOMAC scores (p < 0.001). When CPM is used, early application with initial high flexion and rapid progress benefits knee function up to 6 months after TKA. II.
Seo, Jeong-Hee; Li, Guoan; Shetty, Gautam M; Kim, Ji-Hoon; Bae, Ji-Hoon; Jo, Myoung-Lae; Kim, Jung-Sung; Lee, Sung-Jae; Nha, Kyung-Wook
2009-11-01
Our purpose was to evaluate the result of radial tears at the root of the posterior horn of the medial meniscus (PHMM) in terms of tibiofemoral contact mechanics and the effectiveness of pullout sutures for such tears. Eleven mature pig knees each underwent 15 different testing conditions with an intact, simulated (incised) radial tear at the root of the PHMM and placement of pullout sutures in the radial tears of the medial meniscus at 5 different angles of flexion (0 degrees, 15 degrees, 30 degrees, 60 degrees, and 90 degrees ) under a 1,500-N axial load. A K-Scan pressure sensor (Tekscan, Boston, MA) was used to measure medial tibiofemoral contact area and peak tibiofemoral contact pressure. Data were analyzed to assess the difference in medial contact area and tibiofemoral peak contact pressure among the 3 meniscal conditions at various degrees of knee flexion. The mean contact area was significantly lower, and the peak tibiofemoral contact pressure was significantly high in knees with simulated radial tears at all angles of knee flexion compared with knees with intact menisci (P < .0001). The peak tibiofemoral contact pressure after the pullout suture technique was significantly high at 0 degrees and 15 degrees of flexion (P < .0001) compared with intact knee specimens. Failure of sutures occurred in 45% of the specimens at 0 degrees of flexion. Radial tears at the root of the PHMM in a porcine model significantly increased medial tibiofemoral contact pressure and decreased contact area. Although repair of tears of the PHMM with the pullout suture technique aids in significantly reducing tibiofemoral peak contact pressure between 30 degrees and 90 degrees , it remains significantly high at 0 degrees and 15 degrees of flexion. Pullout sutures for radial tears at the root of the PHMM may lead to an increase in peak medial tibiofemoral contact pressure and may be prone to mechanical failure, especially during the stance (loading) phase of gait (mean, 15 degrees of flexion).
2014-01-01
Background Various head and neck positions in sport horses are significant as they can interfere with upper airway flow mechanics during exercise. Until now, research has focused on subjectively described head and neck positions. The objective of this study was to develop an objective, reproducible method for quantifying head and neck positions accurately. Results Determining the angle between the ridge of the nose and the horizontal plane (ground angle) together with the angle between the ridge of nose and the line connecting the neck and the withers (withers angle) has provided values that allow precise identification of three preselected head and neck positions for performing sport horses. The pharyngeal diameter, determined on lateral radiographs of 35 horses, differed significantly between the established flexed position and the remaining two head and neck positions (extended and neutral). There was a significant correlation between the pharyngeal diameter and the ground angle (Spearman’s rank correlation coefficient −0.769, p < 0.01) as well as between the pharyngeal diameter and the withers angle (Spearman’s rank correlation coefficient 0.774, p < 0.01). Conclusion The combination of the ground angle and the withers angle is a suitable tool for evaluating and distinguishing frequently used head and neck positions in sport horses. The ground angle and the withers angle show significant correlation with the measured pharyngeal diameter in resting horses. Hence, these angles provide an appropriate method for assessing the degree of head and neck flexion. Further research is required to examine the influence of increasing head and neck flexion and the related pharyngeal diameter on upper airway function in exercising horses. PMID:24886564
Recognition of finger flexion motion from ultrasound image: a feasibility study.
Shi, Jun; Guo, Jing-Yi; Hu, Shu-Xian; Zheng, Yong-Ping
2012-10-01
Muscle contraction results in structural and morphologic changes of the related muscle. Therefore, finger flexion can be monitored from measurements of these morphologic changes. We used ultrasound imaging to record muscle activities during finger flexion and extracted features to discriminate different fingers' flexions using a support vector machine (SVM). Registration of ultrasound images before and after finger flexion was performed to generate a deformation field, from which angle features and wavelet-based features were extracted. The SVM was then used to classify the motions of different fingers. The experimental results showed that the overall mean recognition accuracy was 94.05% ± 4.10%, with the highest for the thumb (97%) and the lowest for the ring finger (92%) and the mean F value was 0.94 ± 0.02, indicating high accuracy and reliability of this method. The results suggest that the proposed method has the potential to be used as an alternative method of surface electromyography in differentiating the motions of different fingers. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
The Effect of Distal Location of the Volar Short Arm Splint on the Metacarpophalangeal Joint Motion.
Kim, Joon Yub; Sohn, Dong Wook; Park, Ho Youn; Yoo, Jeong Hyun; Kim, Joo Hak; Jung, Myung Gon; Cho, Jae Ho
2016-06-01
The goals of this study were to compare maximal metacarpophalangeal joint (MCPJ) flexion angles after application of a volar short arm splint at 3 different locations and verify the relations between the three different physical and radiological locations. Forty dominant hands of healthy subjects were analyzed in the study. We defined a transverse skin folding line as a line drawn from the radial aspect of the thenar crease to the ulnar aspect of the distal transverse palmar crease. The distal end of the volar short arm splint was applied on 3 parallel locations to this line. Location A was on this transverse skin folding line; location B was 1 cm proximal to location A; and location C was 1 cm distal to location A. Two orthopedic surgeons measured the maximal MCPJ flexion angles of each finger except the thumb with the application of a volar short arm splint at 3 different locations as well as without a splint as a control. Radiological locations of the 3 different distal ends of the volar short arm splint were also assessed by anteroposterior radiographs of the wrist. When the splint was applied at location A and C, the maximal MCPJ flexion angle decreased to a mean of 83° (91% of control value) and 56° (62% of control value), respectively (compared to the control, p < 0.001). At location B, the maximal MCPJ flexion angle was a mean of 90° (99% of control value); no significant difference was observed compared to the control or without the splint (p = 0.103). On radiography, the average length from the metacarpal head to the distal end of the splint at all fingers decreased in the order of location B, A, and C (29 mm, 19 mm, and 10 mm, respectively; p < 0.001). We recommend applying the distal end of a volar short arm splint at proximal 1 cm to the transverse skin folding line to preserve MCPJ motion perfectly, which is located at distal 44% of the whole metacarpal bone length radiologically.
Influence of the posterior tibial slope on the flexion gap in total knee arthroplasty.
Okazaki, Ken; Tashiro, Yasutaka; Mizu-uchi, Hideki; Hamai, Satoshi; Doi, Toshio; Iwamoto, Yukihide
2014-08-01
Adjusting the joint gap length to be equal in both extension and flexion is an important issue in total knee arthroplasty (TKA). It is generally acknowledged that posterior tibial slope affects the flexion gap; however, the extent to which changes in the tibial slope angle directly affect the flexion gap remains unclear. This study aimed to clarify the influence of tibial slope changes on the flexion gap in cruciate-retaining (CR) or posterior-stabilizing (PS) TKA. The flexion gap was measured using a tensor device with the femoral trial component in 20 cases each of CR- and PS-TKA. A wedge plate with a 5° inclination was placed on the tibial cut surface by switching its front-back direction to increase or decrease the tibial slope by 5°. The flexion gap after changing the tibial slope was compared to that of the neutral slope measured with a flat plate that had the same thickness as that of the wedge plate center. When the tibial slope decreased or increased by 5°, the flexion gap decreased or increased by 1.9 ± 0.6mm or 1.8 ± 0.4mm, respectively, with CR-TKA and 1.2 ± 0.4mm or 1.1 ± 0.3mm, respectively, with PS-TKA. The influence of changing the tibial slope by 5° on the flexion gap was approximately 2mm with CR-TKA and 1mm with PS-TKA. This information is useful when considering the effect of manipulating the tibial slope on the flexion gap when performing CR- or PS-TKA. Copyright © 2014 Elsevier B.V. All rights reserved.
Balanced Flexion and Extension Gaps Are Not Always of Equal Size.
Kinsey, Tracy L; Mahoney, Ormonde M
2018-04-01
It has been widely accepted in total knee arthroplasty (TKA) that flexion and extension gaps in the disarticulated knee during surgery should be equalized. We hypothesized that tensioning during assessment of the flexion gap can induce temporary widening of the gap due to posterior tibial translation. We aimed to describe posterior tibial translation at flexion gap (90°) assessments and assess the correlation of tibial translation with laxity (flexion space increase) using constrained and non-constrained inserts. Imageless navigation was used to measure flexion angle, tibial position relative to the femoral axis, and lateral/medial laxity in 30 patients undergoing primary TKA. Trialing was conducted using posteriorly stabilized and cruciate retaining trials of the same size to elucidate the association of posterior tibial translation with changes in joint capsule laxity at 90° knee flexion. All patients demonstrated posterior tibial translation during flexion gap assessment relative to their subsequent final implantation [mean ± standard deviation (range), 11.3 ± 4.4 (4-21) mm]. Positive linear correlation [r = 0.69, 95% confidence interval (CI) 0.44-0.84, P ≤ .001] was demonstrated between translations [8.7 ± 2.4 (3-13) mm] and laxity changes [2.9° ± 2.0° (-0.7° to 7.4°)] at 90° of flexion. Posterior tibial translation can cause artifactual widening of the flexion gap during gap balancing in posteriorly stabilized TKA, which can be of sufficient magnitude to alter femoral component size selection for some patients. Recognition and management of these intra-operative dynamics for optimal kinematics could be feasible with the advent of robotic applications. Copyright © 2017 Elsevier Inc. All rights reserved.
Weide, Guido; Huijing, Peter A; Maas, Josina C; Becher, Jules G; Harlaar, Jaap; Jaspers, Richard T
2015-01-01
Using a cross-sectional design, the purpose of this study was to determine how pennate gastrocnemius medialis (GM) muscle geometry changes as a function of adolescent age. Sixteen healthy adolescent males (aged 10–19 years) participated in this study. GM muscle geometry was measured within the mid-longitudinal plane obtained from a 3D voxel-array composed of transverse ultrasound images. Images were taken at footplate angles corresponding to standardised externally applied footplate moments (between 4 Nm plantar flexion and 6 Nm dorsal flexion). Muscle activity was recorded using surface electromyography (EMG), expressed as a percentage of maximal voluntary contraction (%MVC). To minimise the effects of muscle excitation, EMG inclusion criteria were set at < 10% of MVC. In practice, however, normalised EMG levels were much lower. For adolescent subjects with increasing ages, GM muscle (belly) length increased due to an increase in the length component of the physiological cross-sectional area measured within the mid-longitudinal plane. No difference was found between fascicles at different ages, but the aponeurosis length and pennation angle increased by 0.5 cm year−1 and 0.5 ° per year, respectively. Footplate angles corresponding to externally applied 0 and 4 Nm plantarflexion moments were not associated with different adolescent ages. In contrast, footplate angles corresponding to externally applied 4 and 6 Nm dorsal flexion moments decreased by 10 ° between 10 and 19 years. In conclusion, we found that in adolescents' pennate GM muscles, longitudinal muscle growth is mediated predominantly by increased muscle fascicle diameter. PMID:25879671
Gaudreault, Nathaly; Mezghani, Neila; Turcot, Katia; Hagemeister, Nicola; Boivin, Karine; de Guise, Jacques A
2011-03-01
Interpreting gait data is challenging due to intersubject variability observed in the gait pattern of both normal and pathological populations. The objective of this study was to investigate the impact of using principal component analysis for grouping knee osteoarthritis (OA) patients' gait data in more homogeneous groups when studying the effect of a physiotherapy treatment. Three-dimensional (3D) knee kinematic and kinetic data were recorded during the gait of 29 participants diagnosed with knee OA before and after they received 12 weeks of physiotherapy treatment. Principal component analysis was applied to extract groups of knee flexion/extension, adduction/abduction and internal/external rotation angle and moment data. The treatment's effect on parameters of interest was assessed using paired t-tests performed before and after grouping the knee kinematic data. Increased quadriceps and hamstring strength was observed following treatment (P<0.05). Except for the knee flexion/extension angle, two different groups (G(1) and G(2)) were extracted from the angle and moment data. When pre- and post-treatment analyses were performed considering the groups, participants exhibiting a G(2) knee moment pattern demonstrated a greater first peak flexion moment, lower adduction moment impulse and smaller rotation angle range post-treatment (P<0.05). When pre- and post-treatment comparisons were performed without grouping, the data showed no treatment effect. The results of the present study suggest that the effect of physiotherapy on gait mechanics of knee osteoarthritis patients may be masked or underestimated if kinematic data are not separated into more homogeneous groups when performing pre- and post-treatment comparisons. Copyright © 2010 Elsevier Ltd. All rights reserved.
Maas, Huub; Baan, Guus C; Huijing, Peter A
2013-01-01
The aim of this paper is to investigate mechanical functioning of a single skeletal muscle, active within a group of (previously) synergistic muscles. For this purpose, we assessed wrist angle-active moment characteristics exerted by a group of wrist flexion muscles in the rat for three conditions: (i) after resection of the upper arm skin; (ii) after subsequent distal tenotomy of flexor carpi ulnaris muscle (FCU); and (iii) after subsequent freeing of FCU distal tendon and muscle belly from surrounding tissues (MT dissection). Measurements were performed for a control group and for an experimental group after recovery (5 weeks) from tendon transfer of FCU to extensor carpi radialis (ECR) insertion. To assess if FCU tenotomy and MT dissection affects FCU contributions to wrist moments exclusively or also those of neighboring wrist flexion muscles, these data were compared to wrist angle-moment characteristics of selectively activated FCU. FCU tenotomy and MT dissection decreased wrist moments of the control group at all wrist angles tested, including also angles for which no or minimal wrist moments were measured when activating FCU exclusively. For the tendon transfer group, wrist flexion moment increased after FCU tenotomy, but to a greater extent than can be expected based on wrist extension moments exerted by selectively excited transferred FCU. We conclude that dissection of a single muscle in any surgical treatment does not only affect mechanical characteristics of the target muscle, but also those of other muscles within the same compartment. Our results demonstrate also that even after agonistic-to-antagonistic tendon transfer, mechanical interactions with previously synergistic muscles do remain present.
Influence of the cranial base flexion on Class I, II and III malocclusions: a systematic review.
Almeida, Kélei Cristina Mathias de; Raveli, Taísa Boamorte; Vieira, Camila Ivini Viana; Santos-Pinto, Ary Dos; Raveli, Dirceu Barnabé
2017-01-01
The aim of this study was to perform a systematic review on the morphological characteristics of the skull base (flexion, anterior length and posterior length) and the concomitant development of malocclusions, by comparing differences in dimorphism, ethnicity and age. The articles were selected by means of electronic search on BBO, MEDLINE and LILACS databases from 1966 to 2016. A qualitative evaluation of the methodologies used on the articles was also performed. Although the literature on this topic is abundant, only 16 articles were selected for the present systematic review. The cranial base angle itself does not seem to play a significant role in the development of malocclusions. In fact, the cranial base angle is relatively stable at the ages of 5 to 15 years. A more obtuse angle at the skull base, in association or not with a greater anterior length of the cranial base, can contribute to the development of Class II division 1 malocclusions. On the other hand, a more acute angle at the skull base can contribute to a more anterior positioning of the mandible and to the development of Class III malocclusions.
Influence of the cranial base flexion on Class I, II and III malocclusions: a systematic review
de Almeida, Kélei Cristina Mathias; Raveli, Taísa Boamorte; Vieira, Camila Ivini Viana; dos Santos-Pinto, Ary; Raveli, Dirceu Barnabé
2017-01-01
ABSTRACT Objective: The aim of this study was to perform a systematic review on the morphological characteristics of the skull base (flexion, anterior length and posterior length) and the concomitant development of malocclusions, by comparing differences in dimorphism, ethnicity and age. Methods: The articles were selected by means of electronic search on BBO, MEDLINE and LILACS databases from 1966 to 2016. A qualitative evaluation of the methodologies used on the articles was also performed. Results: Although the literature on this topic is abundant, only 16 articles were selected for the present systematic review. The cranial base angle itself does not seem to play a significant role in the development of malocclusions. In fact, the cranial base angle is relatively stable at the ages of 5 to 15 years. Conclusions: A more obtuse angle at the skull base, in association or not with a greater anterior length of the cranial base, can contribute to the development of Class II division 1 malocclusions. On the other hand, a more acute angle at the skull base can contribute to a more anterior positioning of the mandible and to the development of Class III malocclusions. PMID:29160345
Quasi-stiffness of the knee joint in flexion and extension during the golf swing.
Choi, Ahnryul; Sim, Taeyong; Mun, Joung Hwan
2015-01-01
Biomechanical understanding of the knee joint during a golf swing is essential to improve performance and prevent injury. In this study, we quantified the flexion/extension angle and moment as the primary knee movement, and evaluated quasi-stiffness represented by moment-angle coupling in the knee joint. Eighteen skilled and 23 unskilled golfers participated in this study. Six infrared cameras and two force platforms were used to record a swing motion. The anatomical angle and moment were calculated from kinematic and kinetic models, and quasi-stiffness of the knee joint was determined as an instantaneous slope of moment-angle curves. The lead knee of the skilled group had decreased resistance duration compared with the unskilled group (P < 0.05), and the resistance duration of the lead knee was lower than that of the trail knee in the skilled group (P < 0.01). The lead knee of the skilled golfers had greater flexible excursion duration than the trail knee of the skilled golfers, and of both the lead and trail knees of the unskilled golfers. These results provide critical information for preventing knee injuries during a golf swing and developing rehabilitation strategies following surgery.
Cheng, Joseph S; Liu, Fei; Komistek, Richard D; Mahfouz, Mohamed R; Sharma, Adrija; Glaser, Diana
2007-11-01
In this cervical spine kinematics study the authors evaluate the motions and forces in the normal, degenerative, and fused states to assess how alteration in the cervical motion segment affects adjacent segment degeneration and spondylosis. Fluoroscopic images obtained in 30 individuals (10 in each group with disease at C5-6) undergoing flexion/extension motions were collected. Kinematic data were obtained from the fluoroscopic images and analyzed with an inverse dynamic mathematical model of the cervical spine that was developed for this analysis. During 20 degrees flexion to 15 degrees extension, average relative angles at the adjacent levels of C6-7 and C4-5 in the fused patients were 13.4 degrees and 8.8 degrees versus 3.7 degrees and 4.8 degrees in the healthy individuals. Differences at C3-4 averaged only about 1 degrees. Maximum transverse forces in the fused spines were two times the skull weight at C6-7 and one times the skull weight at C4-5, compared with 0.2 times the skull weight and 0.3 times the skull weight in the healthy individuals. Vertical forces ranged from 1.6 to 2.6 times the skull weight at C6-7 and from 1.2 to 2.5 times the skull weight at C4-5 in the patients who had undergone fusion, and from 1.4 to 3.1 times the skull weight and from 0.9 to 3.3 times the skull weight, respectively, in the volunteers. Adjacent-segment degeneration may occur in patients with fusion due to increased motions and forces at both adjacent levels when compared with healthy individuals in a comparable flexion and extension range.
Aerodynamics of dynamic wing flexion in translating wings
NASA Astrophysics Data System (ADS)
Liu, Yun; Cheng, Bo; Sane, Sanjay P.; Deng, Xinyan
2015-06-01
We conducted a systematic experimental study to investigate the aerodynamic effects of active trailing-edge flexion on a high-aspect-ratio wing translating from rest at a high angle of attack. We varied the timing and speed of the trailing-edge flexion and measured the resulting aerodynamic effects using a combination of direct force measurements and two-dimensional PIV flow measurements. The results indicated that the force and flow characteristics depend strongly on the timing of flexion, but relatively weakly on its speed. This is because the force and vortical flow structure are more sensitive to the timing of flexion relative to the shedding of starting vortex and leading-edge vortex. When the trailing-edge flexion occurred slightly before the starting vortex was shed, the lift production was greatly improved with the instantaneous peak lift increased by 54 % and averaged lift increased by 21 % compared with the pre-flexed case where the trailing-edge flexed before wing translation. However, when the trailing-edge flexed during or slightly after the leading-edge vortex shedding, the lift was significantly reduced by the disturbed development of leading-edge vortex. The force measurement results also imply that the trailing-edge flexion prior to wing translation does not augment lift but increases drag, thus resulting in a lower lift-drag ratio as compared to the case of flat wing.
Assessment of the midflexion rotational laxity in posterior-stabilized total knee arthroplasty.
Hino, Kazunori; Kutsuna, Tatsuhiko; Oonishi, Yoshio; Watamori, Kunihiko; Kiyomatsu, Hiroshi; Iseki, Yasutake; Watanabe, Seiji; Ishimaru, Yasumitsu; Miura, Hiromasa
2017-11-01
To evaluate changes in midflexion rotational laxity before and after posterior-stabilized (PS)-total knee arthroplasty (TKA). Twenty-nine knees that underwent PS-TKA were evaluated. Manual mild passive rotational stress was applied to the knees, and the internal-external rotational angle was measured automatically by a navigation system at 30°, 45°, 60°, and 90° of knee flexion. The post-operative internal rotational laxity was statistically significantly increased compared to the preoperative level at 30°, 45°, 60°, and 90° of flexion. The post-operative external rotational laxity was statistically significantly decreased compared to the preoperative level at 45° and 60° of flexion. The post-operative internal-external rotational laxity was statistically significantly increased compared to the preoperative level only at 30° of flexion. The preoperative and post-operative rotational laxity showed a significant correlation at 30°, 45°, 60°, and 90° of flexion. Internal-external rotational laxity increases at the initial flexion range due to resection of both the anterior or posterior cruciate ligaments and retention of the collateral ligaments in PS-TKA. Preoperative and post-operative rotational laxity indicated a significant correlation at the midflexion range. This study showed that a large preoperative rotational laxity increased the risk of a large post-operative laxity, especially at the initial flexion range in PS-TKA. III.
The potential of human toe flexor muscles to produce force
Goldmann, Jan-Peter; Brüggemann, Gert-Peter
2012-01-01
The maximal force a muscle produces depends among others on the length of the muscle and therefore on the positions of the joints the muscle crosses. Long and short toe flexor muscles (TFM) cross the ankle joints and metatarsal phalangeal joints (MPJ) and work against gravity during human locomotion. The purpose of this study was to describe the maximal moments around the MPJ during maximal voluntary isometric contractions (MVIC) of the TFM as a function of ankle joint and MPJ position. Twenty men performed MVIC of the TFM in a custom-made dynamometer. Ankle and MPJ angles were modified after each contraction. External moments of force around the MPJ were determined. Moments ranged between 6.3 ± 2.6 Nm and 14.2 ± 5.8 Nm. Highest moments were produced at 0°–10° ankle joint dorsal flexion and 25°–45° MPJ dorsal flexion. Lowest moments were generated at 35° ankle joint plantar flexion and 0° MPJ dorsal flexion. In conclusion, if the ankle is plantar-flexed, dorsal flexion of the MPJ avoids a disadvantage of the force–length relationship of TFM. Therefore, MPJ dorsal flexion is a necessary function in the push-off phase of human locomotion to work against the loss of the mechanical output at the forefoot caused by plantar flexion of the ankle. PMID:22747582
Kinematic classification of iliotibial band syndrome in runners.
Grau, S; Krauss, I; Maiwald, C; Axmann, D; Horstmann, T; Best, R
2011-04-01
Several inconsistent causative biomechanical factors are considered to be crucial in the occurrence of iliotibial band syndrome (ITBS). The focus of this study was on assessing differences in the kinematic characteristics between healthy runners [control group (CO)] and runners with ITBS in order to recommend treatment strategies to deal with this injury. Three-dimensional kinematics of barefoot running was used in the biomechanical setup. Both groups were matched with respect to gender, height and weight. After determining drop outs, the final population comprised 36 subjects (26 male and 10 female): 18 CO and 18 ITBS (13 male and five female, each). Kinematic evaluations indicate less hip adduction and frontal range of motion at the hip joint in runners with ITBS. Furthermore, maximum hip flexion velocity and maximum knee flexion velocity were lower in runners with ITBS. Lack of joint coordination, expressed as earlier hip flexion and a tendency toward earlier knee flexion, was found to be another discriminating variable in subjects with ITBS compared with CO subjects. We assume that an increase in range of motion at the hip joint, stretching of the hip abductors, as well as stretching the hamstrings, calf muscles and hip flexors will help treat ITBS. © 2009 John Wiley & Sons A/S.
Arjunan, Sridhar P; Kumar, Dinesh K; Naik, Ganesh R
2010-01-01
This research paper reports an experimental study on identification of the changes in fractal properties of surface Electromyogram (sEMG) with the changes in the force levels during low-level finger flexions. In the previous study, the authors have identified a novel fractal feature, Maximum fractal length (MFL) as a measure of strength of low-level contractions and has used this feature to identify various wrist and finger movements. This study has tested the relationship between the MFL and force of contraction. The results suggest that changes in MFL is correlated with the changes in contraction levels (20%, 50% and 80% maximum voluntary contraction (MVC)) during low-level muscle activation such as finger flexions. From the statistical analysis and by visualisation using box-plot, it is observed that MFL (p ≈ 0.001) is a more correlated to force of contraction compared to RMS (p≈0.05), even when the muscle contraction is less than 50% MVC during low-level finger flexions. This work has established that this fractal feature will be useful in providing information about changes in levels of force during low-level finger movements for prosthetic control or human computer interface.
Begalle, Rebecca L; Walsh, Meghan C; McGrath, Melanie L; Boling, Michelle C; Blackburn, J Troy; Padua, Darin A
2015-08-01
The ankle, knee, and hip joints work together in the sagittal plane to absorb landing forces. Reduced sagittal plane motion at the ankle may alter landing strategies at the knee and hip, potentially increasing injury risk; however, no studies have examined the kinematic relationships between the joints during jump landings. Healthy adults (N = 30; 15 male, 15 female) performed jump landings onto a force plate while three-dimensional kinematic data were collected. Joint displacement values were calculated during the loading phase as the difference between peak and initial contact angles. No relationship existed between ankle dorsiflexion displacement during landing and three-dimensional knee and hip displacements. However, less ankle dorsiflexion displacement was associated with landing at initial ground contact with larger hip flexion, hip internal rotation, knee flexion, knee varus, and smaller plantar flexion angles. Findings of the current study suggest that restrictions in ankle motion during landing may contribute to contacting the ground in a more flexed position but continuing through little additional motion to absorb the landing. Transverse plane hip and frontal plane knee positioning may also occur, which are known to increase the risk of lower extremity injury.
Kinematic comparison of team handball throwing with two different arm positions.
Wagner, Herbert; Buchecker, Michael; von Duvillard, Serge P; Müller, Erich
2010-12-01
The aims of the present study were: (1) to compare the differences in the ball release speed and throwing accuracy between the ABOVE and SIDE throw; (2) to analyze kinematic differences of these two throwing techniques; and (3) to give practical applications to team handball coaches and players. Ball release speed, throwing accuracy, and kinematics were measured via the Vicon MX 13 (Vicon Peak, Oxford, UK) from 12 male elite right-handed team handball players. Results of our study suggest that the two throwing techniques differ significantly (P < .0073) in the angles and/or angular velocities of the trunk (flexion, left tilt and rotation) and shoulder (flexion and abduction) of the throwing arm that result in a significantly different ball release speed (1.4 ± 0.8 m/s; P < .001) and that throwing accuracy was not significantly different. Our results indicated that the different position of the hand at ball release of the ABOVE and SIDE throws is primarily caused by different trunk flexion and tilt angles that lead to differences in ball release speed but not in throwing accuracy, and that the participants try to move their throwing arm similarly in both throwing techniques.
Lam, Wing-Kai; Ryue, Jaejin; Lee, Ki-Kwang; Park, Sang-Kyoon; Cheung, Jason Tak-Man; Ryu, Jiseon
2017-01-01
Lunge is one frequently executed movement in badminton and involves a unique sagittal footstrike angle of more than 40 degrees at initial ground contact compared with other manoeuvres. This study examined if the shoe heel curvature design of a badminton shoe would influence shoe-ground kinematics, ground reaction forces, and knee moments during lunge. Eleven elite and fifteen intermediate players performed five left-forward maximum lunge trials with Rounded Heel Shoe (RHS), Flattened Heel Shoe (FHS), and Standard Heel Shoes (SHS). Shoe-ground kinematics, ground reaction forces, and knee moments were measured by using synchronized force platform and motion analysis system. A 2 (Group) x 3 (Shoe) ANOVA with repeated measures was performed to determine the effects of different shoes and different playing levels, as well as the interaction of two factors on all variables. Shoe effect indicated that players demonstrated lower maximum vertical loading rate in RHS than the other two shoes (P < 0.05). Group effect revealed that elite players exhibited larger footstrike angle, faster approaching speed, lower peak horizontal force and horizontal loading rates but higher vertical loading rates and larger peak knee flexion and extension moments (P < 0.05). Analysis of Interactions of Group x Shoe for maximum and mean vertical loading rates (P < 0.05) indicated that elite players exhibited lower left maximum and mean vertical loading rates in RHS compared to FHS (P < 0.01), while the intermediate group did not show any Shoe effect on vertical loading rates. These findings indicate that shoe heel curvature would play some role in altering ground reaction force impact during badminton lunge. The differences in impact loads and knee moments between elite and intermediate players may be useful in optimizing footwear design and training strategy to minimize the potential risks for impact related injuries in badminton.
Cheung, Jason Tak-Man; Ryu, Jiseon
2017-01-01
Background Lunge is one frequently executed movement in badminton and involves a unique sagittal footstrike angle of more than 40 degrees at initial ground contact compared with other manoeuvres. This study examined if the shoe heel curvature design of a badminton shoe would influence shoe-ground kinematics, ground reaction forces, and knee moments during lunge. Methods Eleven elite and fifteen intermediate players performed five left-forward maximum lunge trials with Rounded Heel Shoe (RHS), Flattened Heel Shoe (FHS), and Standard Heel Shoes (SHS). Shoe-ground kinematics, ground reaction forces, and knee moments were measured by using synchronized force platform and motion analysis system. A 2 (Group) x 3 (Shoe) ANOVA with repeated measures was performed to determine the effects of different shoes and different playing levels, as well as the interaction of two factors on all variables. Results Shoe effect indicated that players demonstrated lower maximum vertical loading rate in RHS than the other two shoes (P < 0.05). Group effect revealed that elite players exhibited larger footstrike angle, faster approaching speed, lower peak horizontal force and horizontal loading rates but higher vertical loading rates and larger peak knee flexion and extension moments (P < 0.05). Analysis of Interactions of Group x Shoe for maximum and mean vertical loading rates (P < 0.05) indicated that elite players exhibited lower left maximum and mean vertical loading rates in RHS compared to FHS (P < 0.01), while the intermediate group did not show any Shoe effect on vertical loading rates. Conclusions These findings indicate that shoe heel curvature would play some role in altering ground reaction force impact during badminton lunge. The differences in impact loads and knee moments between elite and intermediate players may be useful in optimizing footwear design and training strategy to minimize the potential risks for impact related injuries in badminton. PMID:28334016
Nakamura, Shinichiro; Sharma, Adrija; Kobayashi, Masahiko; Ito, Hiromu; Nakamura, Kenji; Zingde, Sumesh M; Nakamura, Takashi; Komistek, Richard D
2014-01-01
Kneeling position can serve as an important posture, providing stability and balance from a standing position to sitting on the floor or vice-versa. The purpose of the current study was to determine the kinematics during kneeling activities after subjects were implanted with a tri-condylar total knee arthroplasty. Kinematics was evaluated in 54 knees using fluoroscopy and a three-dimensional model fitting approach. The average knee flexion at before contact status, at complete contact and at maximum flexion was 98.1±9.0°, 107.2±6.7°, and 139.6±12.3°, respectively. On average, there was no gross anterior displacement from before contact status to complete contact. Only slight posterior rollback motion of both condyles from complete contact to maximum flexion was observed. Three of 39 (7.7%) knees experienced anterior movement of both condyles more than 2mm from before contact status to complete contact. Reverse rotation pattern from before contact status to complete contact and then normal rotation pattern from complete contact to maximum flexion were observed. Condylar lift-off greater than 1.0 mm was observed in 45 knees (83.3%). The presence of the ball-and-socket joint articulation provides sufficient antero-posterior stability in these designs to enable the patients to kneel safely without the incidence of any dislocation. This study suggests a safe implant design for kneeling. © 2013.
Mechanical factors relate to pain in knee osteoarthritis.
Maly, Monica R; Costigan, Patrick A; Olney, Sandra J
2008-07-01
Pain experienced by people with knee osteoarthritis is related to psychosocial factors and damage to articular tissues and/or the pain pathway itself. Mechanical factors have been speculated to trigger this pain experience; yet mechanics have not been identified as a source of pain in this population. The purpose of this study was to identify whether mechanics could explain variance in pain intensity in people with knee osteoarthritis. Data from 53 participants with physician-diagnosed knee osteoarthritis (mean age=68.5 years; standard deviation=8.6 years) were analyzed. Pain intensity was reported on the Western Ontario and McMaster Universities Osteoarthritis Index. Mechanical measures included weight-bearing varus-valgus alignment, body mass index and isokinetic quadriceps torque. Gait analysis captured the range of adduction-abduction angle, range of flexion-extension angle and external knee adduction moment during level walking. Pain intensity was significantly related to the dynamic range of flexion-extension during gait and body mass index. A total of 29% of the variance in pain intensity was explained by mechanical variables. The range of flexion-extension explained 18% of variance in pain intensity. Body mass index added 11% to the model. The knee adduction moment was unrelated to pain intensity. The findings support that mechanical factors are related to knee osteoarthritis pain. Because limitations in flexion-extension range of motion and body size are modifiable factors, future research could examine whether interventions targeting these mechanics would facilitate pain management.
Athwal, Kiron K; Daou, Hadi El; Kittl, Christoph; Davies, Andrew J; Deehan, David J; Amis, Andrew A
2016-08-01
The aim of this study was to quantify the contributions of medial soft tissues to stability following cruciate-retaining (CR) or posterior-stabilised (PS) total knee arthroplasty (TKA). Using a robotic system, eight cadaveric knees were subjected to ±90-N anterior-posterior force, ±5-Nm internal-external and ±8-Nm varus-valgus torques at various flexion angles. The knees were tested intact and then with CR and PS implants, and successive cuts of the deep and superficial medial collateral ligaments (dMCL, sMCL) and posteromedial capsule (PMC) quantified the percentage contributions of each structure to restraining the applied loads. In implanted knees, the sMCL restrained valgus rotation (62 % across flexion angles), anterior-posterior drawer (24 and 10 %, respectively) and internal-external rotation (22 and 37 %). Changing from CR TKA to PS TKA increased the load on the sMCL when resisting valgus loads. The dMCL restrained 11 % of external and 13 % of valgus rotations, and the PMC was significant at low flexion angles. This work has shown that medial release in the varus knee should be minimised, as it may inadvertently result in a combined laxity pattern. There is increasing interest in preserving constitutional varus in TKA, and this work argues for preservation of the sMCL to afford the surgeon consistent restraint and maintain a balanced knee for the patient.
Foss, K.; da Costa, R.C.; Moore, S.
2014-01-01
Background The optimal treatment of cervical spondylomyelopathy (CSM) is controversial, with the owner’s and clinician’s perception of gait improvement often being used as outcome measures. These methods are subjective and suffer from observer bias. Objectives To establish kinematic gait parameters utilizing digital motion capture in normal Doberman Pinschers and compare them with CSM-affected Dobermans. Animals Nineteen Doberman Pinschers; 10 clinically normal and 9 with CSM. Methods All dogs were enrolled prospectively and fitted with a Lycra® body suit, and motion capture was performed and used to reconstruct a 3-D stick diagram representation of each dog based on 32 reflective markers, from which several parameters were measured. These included stride duration, length, and height; maximal and minimal spinal angles; elbow and stifle flexion and extension; and maximum and minimum distances between the thoracic and pelvic limbs. A random-effects linear regression model was used to compare parameters between groups. Results Significant differences between groups included smaller minimum (mean = 116 mm; P = .024) and maximum (mean = 184 mm; P = .001) distance between the thoracic limbs in CSM-affected dogs. Additionally, thoracic limb stride duration was also smaller (P = .009) in CSM-affected dogs (mean = 0.7 seconds) when compared with normal dogs (mean = 0.8 seconds). In the pelvic limbs, the average stifle flexion (mean = 100°; P = .048) and extension (mean = 136°; P = .009), as well as number of strides (mean = 2.7 strides; P = .033) were different between groups. Conclusions and Clinical Importance Our findings suggest that computerized gait analysis reveals more consistent kinematic differences in the thoracic limbs, which can be used as future objective outcome measures. PMID:23194100
Yang, Peng-Fei; Kriechbaumer, Andreas; Albracht, Kirsten; Sanno, Maximilian; Ganse, Bergita; Koy, Timmo; Shang, Peng; Brüggemann, Gert-Peter; Müller, Lars Peter; Rittweger, Jörn
2015-02-05
The mechanical relationship between bone and muscle has been long recognized. However, it still remains unclear how muscles exactly load on bone. In this study, utilizing an optical segment tracking technique, the in vivo tibia loading regimes in terms of tibia segment deformation in humans were investigated during walking, forefoot and rear foot stair ascent and running and isometric plantar flexion. Results suggested that the proximal tibia primarily bends to the posterior aspect and twists to the external aspect with respect to the distal tibia. During walking, peak posterior bending and peak torsion occurred in the first half (22%) and second half (76%) of the stance phase, respectively. During stair ascent, two noticeable peaks of torsion were found with forefoot strike (38% and 82% of stance phase), but only one peak of torsion was found with rear foot strike (78% of stance phase). The torsional deformation angle during both stair ascent and running was larger with forefoot strike than rear foot strike. During isometric plantar flexion, the tibia deformation regimes were characterized more by torsion (maximum 1.35°) than bending (maximum 0.52°). To conclude, bending and torsion predominated the tibia loading regimes during the investigated activities. Tibia torsional deformation is closely related to calf muscle contractions, which further confirm the notion of the muscle-bone mechanical link and shift the focus from loading magnitude to loading regimes in bone mechanobiology. It thus is speculated that torsion is another, yet under-rated factor, besides the compression and tension, to drive long bone mechano-adaptation. Copyright © 2014 Elsevier Ltd. All rights reserved.
Hopper, Amanda J.; Haff, Erin E.; Joyce, Christopher; Lloyd, Rhodri S.; Haff, G. Gregory
2017-01-01
The purpose of this study was to examine the effects of a neuromuscular training (NMT) program on lower-extremity biomechanics in youth female netball athletes. The hypothesis was that significant improvements would be found in landing biomechanics of the lower-extremities, commonly associated with anterior cruciate ligament (ACL) injury, following NMT. Twenty-three athletes (age = 12.2 ± 0.9 years; height = 1.63 ± 0.08 m; mass = 51.8 ± 8.5 kg) completed two testing sessions separated by 7-weeks and were randomly assigned to either a experimental or control group. Thirteen athletes underwent 6-weeks of NMT, while the remaining 10 served as controls and continued their regular netball training. Three-dimensional lower-extremity kinematics and vertical ground reaction force (VGRF) were measured during two landing tasks, a drop vertical jump and a double leg broad jump with a single leg landing. The experimental group significantly increased bilateral knee marker distance during the bilateral landing task at maximum knee-flexion range of motion. Knee internal rotation angle during the unilateral landing task at maximum knee flexion-extension range of motion was significantly reduced (p ≤ 0.05, g > 1.00). The experimental group showed large, significant decreases in peak vertical ground reaction force in both landing tasks (p ≤ 0.05, g > −1.30). Control participants did not demonstrate any significant pre-to-post-test changes in response to the 6-week study period. Results of the study affirm the hypothesis that a 6-week NMT program can enhance landing biomechanics associated with ACL injury in 11–13 year old female netball athletes. PMID:29163219
Khan, Abid Ali; O'Sullivan, Leonard; Gallwey, Timothy J
2009-10-01
This study investigated perceived discomfort in an isometric wrist flexion task. Independent variables were wrist flexion/extension (55%, 35% flexion, neutral, 35% and 55% extension ranges of motion (ROM)), forearm rotation (60%, 30% prone, neutral, 30% and 60% supine ROM) and two levels of flexion force (10% and 20% maximum voluntary contraction (MVC)). Discomfort was significantly affected by flexion force, forearm rotation and a two-way interaction of force with forearm rotation (each p < 0.05). High force for 60%ROM forearm pronation and supination resulted in increasingly higher discomfort for these combinations. Flexion forces were set relative to the MVC in each wrist posture and this appears to be important in explaining a lack of significant effect (p = 0.34) for flexion/extension on discomfort. Regression equations predicting discomfort were developed and used to generate iso-discomfort contours, which indicate regions where the risk of injury should be low and others where it is likely to be high. Regression equations predicting discomfort and iso-discomfort contours are presented, which indicate combinations of upper limb postures for which discomfort is predicted to be low, and others where it is likely to be high. These are helpful in the study of limits for risk factors associated with upper limb musculoskeletal injury in industry.
Ferris, Lauren A; Denney, Linda M; Maletsky, Lorin P
2013-02-01
Functional activities in daily life can require squatting and shifting body weight during transverse plane rotations. Stability of the knee can be challenging for people with a total knee replacement (TKR) due to reduced proprioception, nonconforming articular geometry, muscle strength, and soft tissue weakness. The objective of this study was to identify strategies utilized by individuals with TKR in double-stance transferring load during rotation and flexion. Twenty-three subjects were recruited for this study: 11 TKR subjects (age: 65 ± 6 years; BMI 27.4 ± 4.1) and 12 healthy subjects (age: 63 ± 7; BMI 24.6 ± 3.8). Each subject completed a novel crossover button push task where rotation, flexion, and extension of the knee were utilized. Each subject performed two crossover reaching tasks where the subject used the opposite hand to cross over their body and press a button next to either their shoulder (high) or knee (low), then switched hands and rotated to press the opposite button, either low or high. The two tasks related to the order they pressed the buttons while crossing over, either low-to-high (L2H) or high-to-low (H2L). Force platforms measured ground reaction forces under each foot, which were then converted to lead force ratios (LFRs) based on the total force. Knee flexion angles were also measured. No statistical differences were found in the LFRs during the H2L and L2H tasks for the different groups, although differences in the variation of the loading within subjects were noted. A significant difference was found between healthy and unaffected knee angles and a strong trend between healthy and affected subject's knee angles in both H2L and L2H tasks. Large variations in the LFR at mid-task in the TKR subjects suggested possible difficulties in maintaining positional stability during these tasks. The TKR subjects maintained more of an extended knee, which is a consistent quadriceps avoidance strategy seen by other researchers in different tasks. These outcomes suggest that individuals with a TKR utilize strategies, such as keeping an extended knee, to achieve rotary tasks during knee flexion and extension. Repeated compensatory movements could result in forces that may cause difficulty over time in the hip joints or low back. Early identification of these strategies could improve TKR success and the return to activities of daily living that involve flexion and rotation.
Body size and lower limb posture during walking in humans.
Hora, Martin; Soumar, Libor; Pontzer, Herman; Sládek, Vladimír
2017-01-01
We test whether locomotor posture is associated with body mass and lower limb length in humans and explore how body size and posture affect net joint moments during walking. We acquired gait data for 24 females and 25 males using a three-dimensional motion capture system and pressure-measuring insoles. We employed the general linear model and commonality analysis to assess the independent effect of body mass and lower limb length on flexion angles at the hip, knee, and ankle while controlling for sex and velocity. In addition, we used inverse dynamics to model the effect of size and posture on net joint moments. At early stance, body mass has a negative effect on knee flexion (p < 0.01), whereas lower limb length has a negative effect on hip flexion (p < 0.05). Body mass uniquely explains 15.8% of the variance in knee flexion, whereas lower limb length uniquely explains 5.4% of the variance in hip flexion. Both of the detected relationships between body size and posture are consistent with the moment moderating postural adjustments predicted by our model. At late stance, no significant relationship between body size and posture was detected. Humans of greater body size reduce the flexion of the hip and knee at early stance, which results in the moderation of net moments at these joints.
Lemaire, Edward D; Samadi, Reza; Goudreau, Louis; Kofman, Jonathan
2013-01-01
A linear piston hydraulic angular-velocity-based control knee joint was designed for people with knee-extensor weakness to engage knee-flexion resistance when knee-flexion angular velocity reaches a preset threshold, such as during a stumble, but to otherwise allow free knee motion. During mechanical testing at the lowest angular-velocity threshold, the device engaged within 2 degrees knee flexion and resisted moment loads of over 150 Nm. The device completed 400,000 loading cycles without mechanical failure or wear that would affect function. Gait patterns of nondisabled participants were similar to normal at walking speeds that produced below-threshold knee angular velocities. Fast walking speeds, employed purposely to attain the angular-velocity threshold and cause knee-flexion resistance, reduced maximum knee flexion by approximately 25 degrees but did not lead to unsafe gait patterns in foot ground clearance during swing. In knee collapse tests, the device successfully engaged knee-flexion resistance and stopped knee flexion with peak knee moments of up to 235.6 Nm. The outcomes from this study support the potential for the linear piston hydraulic knee joint in knee and knee-ankle-foot orthoses for people with lower-limb weakness.
Interdependency of the maximum range of flexion-extension of hand metacarpophalangeal joints.
Gracia-Ibáñez, V; Vergara, M; Sancho-Bru, J-L
2016-12-01
Mobility of the fingers metacarpophalangeal (MCP) joints depends on the posture of the adjacent ones. Current Biomechanical hand models consider fixed ranges of movement at joints, regardless of the posture, thus allowing for non-realistic postures, generating wrong results in reach studies and forward dynamic analyses. This study provides data for more realistic hand models. The maximum voluntary extension (MVE) and flexion (MVF) of different combinations of MCP joints were measured covering their range of motion. Dependency of the MVF and MVE on the posture of the adjacent MCP joints was confirmed and mathematical models obtained through regression analyses (RMSE 7.7°).
Role of the Middle Lumbar Fascia on Spinal Mechanics: A Human Biomechanical Assessment.
Ranger, Tom A; Newell, Nicolas; Grant, Caroline A; Barker, Priscilla J; Pearcy, Mark J
2017-04-15
Biomechanical experiment. The aims of the present study were to test the effect of fascial tension on lumbar segmental axial rotation and lateral flexion and the effect of the angle of fascial attachment. Tension in the middle layer of lumbar fascia has been demonstrated to affect mechanical properties of lumbar segmental flexion and extension in the neutral zone. The effect of tension on segmental axial rotation and lateral flexion has, however, not been investigated. Seven unembalmed lumbar spines were divided into segments and mounted for testing. A 6 degree-of-freedom robotic testing facility was used to displace the segments in each anatomical plane (flexion-extension, lateral bending, and axial rotation) with force and moment data recorded by a load cell positioned beneath the test specimen. Tests were performed with and without a 20 N fascia load and the subsequent forces and moments were compared. In addition, forces and moments were compared when the specimens were held in a set position and the fascia loading angle was varied. A fascial tension of 20 N had no measurable effect on the forces or moments measured when the specimens were displaced in any plane of motion (P > 0.05). When 20 N of fascial load were applied to motion segments in a set position small segmental forces and moments were measured. Changing the angle of the fascial load did not significantly alter these measurements. Application of a 20 N fascial load did not produce a measureable effect on the mechanics of a motion segment, even though it did produce small measurable forces and moments on the segments when in a fixed position. Results from the present study are inconsistent with previous studies, suggesting that further investigation using multiple testing protocols and different loading conditions is required to determine the effects of fascial loading on spinal segment behavior. N/A.
Slater, Lindsay V; Hart, Joseph M; Kelly, Adam R; Kuenze, Christopher M
2017-09-01
Anterior cruciate ligament (ACL) injury and ACL reconstruction (ACLR) result in persistent alterations in lower extremity movement patterns. The progression of lower extremity biomechanics from the time of injury has not been described. To compare the 3-dimensional (3D) lower extremity kinematics and kinetics of walking among individuals with ACL deficiency (ACLD), individuals with ACLR, and healthy control participants from 3 to 64 months after ACLR. We searched PubMed and Web of Science from 1970 through 2013. We selected only articles that provided peak kinematic and kinetic values during walking in individuals with ACLD or ACLR and comparison with a healthy control group or the contralateral uninjured limb. A total of 27 of 511 identified studies were included. Weighted means, pooled standard deviations, and 95% confidence intervals were calculated for the healthy control, ACLD, and ACLR groups at each reported time since surgery. The magnitude of between-groups (ACLR versus ACLD, control, or contralateral limb) differences at each time point was evaluated using Cohen d effect sizes and associated 95% confidence intervals. Peak knee-flexion angle (Cohen d = -0.41) and external knee-extensor moment (Cohen d = -0.68) were smaller in the ACLD than in the healthy control group. Peak knee-flexion angle (Cohen d range = -0.78 to -1.23) and external knee-extensor moment (Cohen d range = -1.39 to -2.16) were smaller in the ACLR group from 10 to 40 months after ACLR. Reductions in external knee-adduction moment (Cohen d range = -0.50 to -1.23) were present from 9 to 42 months after ACLR. Reductions in peak knee-flexion angle, external knee-flexion moment, and external knee-adduction moment were present in the ACLD and ACLR groups. This movement profile during the loading phase of gait has been linked to knee-cartilage degeneration and may contribute to the development of osteoarthritis after ACLR.
Han, Hyuk-Soo; Kang, Seung-Baik
2013-05-01
The long-term survivorship of TKA in Asian countries is comparable to that in Western countries. High-flexion TKA designs were introduced to improve flexion after TKA. However, several studies suggest high-flexion designs are at greater risk of femoral component loosening compared with conventional TKA designs. We previously reported a revision rate of 21% at 11 to 45 months; this report is intended as a followup to that study. Do implant survival and function decrease with time and do high-flexion activities increase the risk of premature failure? We prospectively followed 72 Nexgen LPS-flex fixed TKAs in 47 patients implanted by a single surgeon between March 2003 and September 2004. We determined the probability of survival using revision as an end point and compared survival between those who could and those who could not perform high-flexion activities. Minimum followup was 0.9 years (median, 6.5 years; range, 0.9-8.6 years). Twenty-five patients (33 knees) underwent revision for aseptic loosening of the femoral component at a mean of 4 years (range, 1-8 years). The probability of revision-free survival for aseptic loosening was 67% and 52% at 5 and 8 years, respectively. Eight-year cumulative survivorship was lower in patients capable of squatting, kneeling, or sitting crosslegged (31% compared with 78%). There were no differences in the pre- and postoperative mean Hospital for Special Surgery scores and maximum knee flexion degrees whether or not high-flexion activities could be achieved. Overall midterm high-flexion TKA survival in our Asian cohort was lower than that of conventional and other high-flexion designs. This unusually high rate of femoral component loosening was associated with postoperative high-flexion activities.
Harry, John R; Freedman Silvernail, Julia; Mercer, John A; Dufek, Janet S
2017-12-01
Although impact phase differences between vertical jump landings (VJL) and step-off landings (STL) may be related to task-specific pre-contact strategies, pre-contact mechanics are rarely examined. Thus, pre-contact kinematics and vertical ground reaction force (vGRF) impulse were examined between VJL and STL. Ten health adults (20.9 ± 1.6 yrs; 167.8 ± 4.2 cm; 68.5 ± 7.15 kg) performed 15 VJL and 15 STL from equal heights. Limb (lead; trail) by task (VJL; STL) ANOVAs (α = 0.05) compared hip, knee, and ankle joint angles 150 ms pre-contact, 100 ms pre-contact, 50 ms pre-contact, and at ground contact. Joint angular displacement was also evaluated between 150 ms pre-contact and ground contact. vGRF impulse was compared during the loading (ground contact to peak vGRF) and attenuation (peak vGRF to end of impact) phases. Greater hip flexion angles occurred during STL versus VJL at each event except 150 ms pre-contact (p ≤ .004). Trail limb knee flexion angles were greater at each event when compared to the lead limb during STL (p ≤ .019). Greater trail limb knee flexion angles occurred during STL versus VJL at all four events (p ≤ .018), while greater plantarflexion angles occurred at all four events during VJL versus STL (p ≤ .034). During STL, greater trail limb plantarflexion angles were detected at each event versus the lead limb (p < .001). Lesser hip, lead and trail limb knee displacement occurred during STL versus VJL (p < .05). Greater vGRF impulse was detected during the loading phase of VJL (<.001), while greater vGRF impulse occurred during the attenuation phase of STL (p = .025). These tasks are characterized by distinct pre-contact kinematic strategies and post-contact kinetics. The task utilized in practice should reflect the requirements of the population of interest. Copyright © 2017 Elsevier B.V. All rights reserved.
Shoulder arthrodesis in adult brachial plexus injury: what is the optimal position?
Sousa, R; Pereira, A; Massada, M; Trigueiros, M; Lemos, R; Silva, C
2011-09-01
Brachial plexus injuries are a major indication for shoulder arthrodesis. However, there is no consensus concerning the optimal position of the glenohumeral joint for fusion. Between 1997 and 2008, 19 shoulder arthrodeses were performed using pelvic reconstruction plates. The radiographic and functional characteristics of 13 patients of mean age 46 years were examined at a mean of 101 months after arthrodesis. Arthrodeses showed 30° mean angle of abduction, 32° forward flexion and 44° internal rotation of the humerus with respect to the scapula. Abduction >35° and forward flexion ≥30° seem to offer slightly better functional results. Internal rotation ≤45° significantly relates to better ability of the hand to reach the face (p = 0.012). Neither abduction >35° nor forward flexion ≥30° showed a higher prevalence of periscapular pain. Abduction around 35° and forward flexion around 30° are needed for good functional results. Internal rotation should not exceed 45°.
Cartilage loss patterns within femorotibial contact regions during deep knee bend.
Michael Johnson, J; Mahfouz, Mohamed R
2016-06-14
Osteoarthritis (OA) can alter knee kinematics and stresses. The relationship between cartilage loss in OA and kinematics is unclear, with existing work focusing on static wear and morphology. In this work, femorotibial cartilage maps were coupled with kinematics to investigate the relationship between kinematics and cartilage loss, allowing for more precise treatment and intervention. Cartilage thickness maps were created from healthy and OA subgroups (varus, valgus, and neutral) and mapped to a statistical bone atlas. Video fluoroscopy determined contact regions from 0° to 120° flexion. Varus and valgus subgroups displayed different wear patterns across the range of flexion, with varus knees showing more loss in early flexion and valgus in deeper flexion. For the femur, varus knees had more wear in the medial compartment than neutral or valgus and most wear at both 0° and 20° flexion. In the lateral femoral compartment, the valgus subgroup showed significantly more wear from 20° to 60° flexion as compared to other angles, though varus knees displayed highest magnitude of wear. For the tibia, most medial wear occurred at 0-40° flexion and most lateral occurred after 60° flexion. Knowing more about cartilage changes in OA knees provides insight as to expected wear or stresses on implanted components after arthroplasty. Combining cartilage loss patterns with kinematics allows for pre-surgical intervention and treatments tailored to the patient׳s alignment and kinematics. Reported wear patterns may also serve as a gauge for post-operative loading to be considered when placing implant components. Copyright © 2016. Published by Elsevier Ltd.
Ithurburn, Matthew P; Paterno, Mark V; Ford, Kevin R; Hewett, Timothy E; Schmitt, Laura C
2015-11-01
Young athletes who have had anterior cruciate ligament (ACL) reconstruction demonstrate suboptimal rates of return to sport, high rates of second ACL injuries, and persistent movement asymmetries. Therefore, the influence of musculoskeletal impairments on movement mechanics in this population needs to be further evaluated. The primary hypothesis was that among young athletes who have had ACL reconstruction, those with greater quadriceps strength asymmetry would demonstrate altered single-leg drop-landing mechanics at return to sport compared with individuals with more symmetric quadriceps strength and also compared with healthy controls (ie, those with no ACL reconstruction). A second hypothesis was that quadriceps strength symmetry would predict single-leg drop-landing symmetry in individuals who have undergone ACL reconstruction. Controlled laboratory study. The study entailed a total of 103 participants (age, 17.4 years) at the time of return to sport after ACL reconstruction and 47 control participants (age, 17.0 years). The quadriceps index (QI) was calculated for isometric quadriceps strength, which was then used to divide the ACL reconstruction participants into high-quadriceps (QI ≥90%; n = 52) and low-quadriceps (QI <85%; n = 41) subgroups. Biomechanical data were collected by use of 3-dimensional motion analysis during a single-leg drop-landing task. The LSI was calculated for kinematic and kinetic sagittal-plane variables of interest during landing. Group differences were compared by use of 1-way analysis of variance and linear regression analyses (α < .05). Both the low- and high-quadriceps groups demonstrated greater limb asymmetry during landing compared with the control group in knee flexion excursion (mean LSI ± SD: low quadriceps, 85.8% ± 15.5% [P < .001]; high quadriceps, 94.2% ± 15.6% [P = .019]; control, 102.7% ± 14.1%), peak trunk flexion angle (low quadriceps, 129.2% ± 36.6% [P < .001]; high quadriceps, 110.5% ± 22.6% [P = .03]; control, 95.5% ± 26.2%), and peak knee extension moment (low quadriceps, 79.5% ± 25.2% [P < .001]; high quadriceps, 89.9% ± 19.8% [P = .005]; control, 102.2% ± 10.9%). Compared with the high-quadriceps group, the low-quadriceps group also demonstrated greater asymmetry during landing in knee flexion excursion (P = .026), peak trunk flexion angle (P = .006), and peak knee extension moment (P = .034). In the ACL reconstruction group, quadriceps strength symmetry predicted symmetry in knee flexion excursion, peak trunk flexion, and peak knee extension moment (all P < .001) and predicted symmetry in peak trunk flexion angle (P < .001) after controlling for graft type, knee-related pain, function with activities of daily living, and sport function. At the time of return to sport, athletes who had undergone ACL reconstruction, including those in both the high- and low-quadriceps groups, demonstrated asymmetry during a single-leg drop-landing task compared with controls. Compensations included increased trunk flexion, decreased knee flexion excursion, and decreased knee extension moments on the involved limb. In addition, individuals in the low-quadriceps group demonstrated greater movement asymmetry compared with individuals in the high-quadriceps group. Restoration of symmetric quadriceps strength after ACL reconstruction is associated with more symmetric mechanics during a single-leg drop-landing movement. However, this appears to be multifactorial, as the high-quadriceps group also demonstrated landing asymmetries. Restoration of symmetric quadriceps strength may improve postoperative athletic participation; however, future study is warranted. © 2015 The Author(s).
Teske, Wolfram; Schwert, Martin; Zirke, Sonja; von Schulze Pellengahr, Christoph; Wiese, Matthias; Lahner, Matthias
2015-01-01
The spinal canal stenosis is a common disease in elderly. The thecal sac narrowing is considered as the anatomical cause for the disease. There is evidence that the anatomical proportions of the lumbar spinal canal are influenced by postural changes. The liquor volume shift during these postural changes is a valuable parameter to estimate the dynamic qualities of this disease. The aim of this human cadaver study was the determination of intrathecal fluid volume changes during the lumbar flexion and the extension. A special measuring device was designed and built for the study to investigate this issue under controlled conditions. The measuring apparatus fixed the lumbar spine firmly and allowed only flexion and extension. The dural sac was closed water tight. The in vitro changes of the intrathecal volumes during the motion cycle were determined according to the principle of communicating vessels. Thirteen human cadaver spines from the Institute of Anatomy were examined in a test setting with a continuous adjustment of motion. The diagnosis of the lumbar spinal stenosis was confirmed by a positive computer tomography prior testing. The volume changes during flexion and extension cycles were measured stepwise in a 2 degree distance between 18° flexion and 18° extension. Three complete series of measurements were performed for each cadaver. Two specimens were excluded because of fluid leaks from further investigation. The flexion of the lumbar spine resulted in an intrathecal volume increase. The maximum volume effects were seen in the early flexion positions of 2° and 4°. The spine reclination resulted in a volume reduction. The maximum extension effect was seen between 14° and 16°. According to our results, remarkable volume effects were seen in the early movements of the lumbar spine especially for the flexion. The results support the concept of the spinal stenosis as a dynamic disease and allow a better understanding of the pathophysiology of this nosological entity. Under clinical aspects our data support the value of a body upright position under avoiding of extended spinal inclination and reclination.
A feedback inclusive neuromuscular training program alters frontal plane kinematics.
Greska, Eric K; Cortes, Nelson; Van Lunen, Bonnie L; Oñate, James A
2012-06-01
Anterior cruciate ligament (ACL) neuromuscular training programs have demonstrated beneficial effects in reducing ACL injuries, yet further evaluation of their effects on biomechanical measures across a sports team season is required to elucidate the specific factors that are modifiable. The purpose of this study was to evaluate the effects of a 10-week off-season neuromuscular training program on lower extremity kinematics. Twelve Division I female soccer players (age: 19.2 ± 0.8 years, height: 1.67 ± 0.1 m, weight: 60.2 ± 6.5 kg) performed unanticipated dynamic trials of a running stop-jump task pretraining and posttraining. Data collection was performed using an 8-camera Vicon system (Los Angeles, CA, USA) and 2 Bertec (Columbus, OH, USA) force plates. The 10-week training program consisted of resistance training 2 times per week and field training, consisting of plyometric, agility, and speed drills, 2 times per week. Repeated measures analyses of variance (ANOVAs) were used to assess the differences between pretraining and posttraining kinetics and kinematics of the hip, knee, and ankle at initial contact (IC), peak knee flexion (PKF), and peak stance. Repeated measures ANOVAs were also used to assess isometric strength differences pretraining and posttraining. The alpha level was set at 0.05 a priori. The training program demonstrated significant increases in left hip extension, left and right hip flexion, and right hip adduction isometric strength. At IC, knee abduction angle moved from an abducted to an adducted position (-1.48 ± 3.65° to 1.46 ± 3.86°, p = 0.007), and hip abduction angle increased (-6.05 ± 4.63° to -10.34 ± 6.83°, p = 0.007). Hip abduction angle at PKF increased (-2.23 ± 3.40° to 6.01 ± 3.82°, p = 0.002). The maximum knee extension moment achieved at peak stance increased from pretraining to posttraining (2.02 ± 0.32 to 2.38 ± 0.75 N·m·kg⁻¹, p = 0.027). The neuromuscular training program demonstrated a potential positive effect in altering mechanics that influence the risk of incurring an ACL injury.
Farrow, Lutul D; Parker, Richard D
2010-06-01
Anatomic reconstruction of the anterior cruciate ligament through an accessory medial portal has become increasingly popular. The purpose of this study is to describe the relationship of guide pin exit points to the lateral anatomic structures when preparing the anterior cruciate ligament femoral tunnel through an accessory medial portal. We utilized seven fresh frozen cadaveric knees. Utilizing an anteromedial approach, a guide wire was placed into the center of each bundle's footprint. Each guide wire was advanced through the lateral femoral cortex. The guide pins were passed at 90, 110, and 130 degrees of knee flexion. The distances from each guide pin to the closest relevant structures on the lateral side of the knee were measured. At 90 degrees the posterolateral bundle guide pin was closest to the lateral condyle articular cartilage (mean 5.4 +/- 2.2 mm) and gastrocnemius tendon (mean 5.7 +/- 2.1 mm). At 110 degrees the posterolateral bundle pin was closest to the gastrocnemius tendon (mean 4.5 +/- 3.4 mm). At 130 degrees the posterolateral bundle pin was closest to the gastrocnemius tendon (mean 7.2 +/- 5.5 mm) and lateral collateral ligament (mean 6.8 +/- 2.1 mm). At 90 degrees the anteromedial bundle guide pin was closest to the articular cartilage (mean 2.0 +/- 2.0 mm). At 110 degrees the anteromedial bundle pin was closest to the articular cartilage (mean 7.4 +/- 3.5 mm) and gastrocnemius tendon (mean 12.3 +/- 3.1 mm). At 130 degrees the AM bundle pin was closest to the gastrocnemius tendon (mean 8.2 +/- 3.2 mm) and LCL (mean 15.1 +/- 2.9 mm). Neither guide pin (anteromedial or posterolateral bundle) put the peroneal nerve at risk at any knee flexion angle. At low knee flexion angles the anteromedial and posterolateral bundle guide pins closely approximated multiple lateral structures when using an accessory medial arthroscopic portal. Utilizing higher flexion angles increases the margin of error when preparing both femoral tunnels. During preparation of the anterior cruciate ligament femoral tunnel through an accessory anteromedial portal the tunnels should be drilled in at least 110 degrees of knee flexion in order to move guide pin exit points away from important lateral knee structures.
Alterations in neuromuscular function in girls with generalized joint hypermobility.
Jensen, Bente Rona; Sandfeld, Jesper; Melcher, Pia Sandfeld; Johansen, Katrine Lyders; Hendriksen, Peter; Juul-Kristensen, Birgit
2016-10-03
Generalized Joint Hypermobility (GJH) is associated with increased risk of musculoskeletal joint pain. We investigated neuromuscular performance and muscle activation strategy. Girls with GJH and non-GJH (NGJH) performed isometric knee flexions (90°,110°,130°), and extensions (90°) at 20 % Maximum Voluntary Contraction, and explosive isometric knee flexions while sitting. EMG was recorded from knee flexor and extensor muscles. Early rate of torque development was 53 % faster for GJH. Reduced hamstring muscle activation in girls with GJH was found while knee extensor and calf muscle activation did not differ between groups. Flexion-extension and medial-lateral co-activation ratio during flexions were higher for girls with GJH than NGJH girls. Girls with GJH had higher capacity to rapidly generate force than NGJH girls which may reflect motor adaptation to compensate for hypermobility. Higher medial muscle activation indicated higher levels of medial knee joint compression in girls with GJH. Increased flexion-extension co-activation ratios in GJH were explained by decreased agonist drive to the hamstrings.
Kloosterman, Marieke G M; Buurke, Jaap H; de Vries, Wiebe; Van der Woude, Lucas H V; Rietman, Johan S
2015-10-01
This study aims to compare hand-rim and power-assisted hand-rim propulsion on potential risk factors for shoulder overuse injuries: intensity and repetition of shoulder loading and force generation in the extremes of shoulder motion. Eleven experienced hand-rim wheelchair users propelled an instrumented wheelchair on a treadmill while upper-extremity kinematic, kinetic and surface electromyographical data was collected during propulsion with and without power-assist. As a result during power-assisted propulsion the peak resultant force exerted at the hand-rim decreased and was performed with significantly less abduction and internal rotation at the shoulder. At shoulder level the anterior directed force and internal rotation and flexion moments decreased significantly. In addition, posterior and the minimal inferior directed forces and the external rotation moment significantly increased. The stroke angle decreased significantly, as did maximum shoulder flexion, extension, abduction and internal rotation. Stroke-frequency significantly increased. Muscle activation in the anterior deltoid and pectoralis major also decreased significantly. In conclusion, compared to hand-rim propulsion power-assisted propulsion seems effective in reducing potential risk factors of overuse injuries with the highest gain on decreased range of motion of the shoulder joint, lower peak propulsion force on the rim and reduced muscle activity. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Mückley, Thomas; Hoffmeier, Konrad; Klos, Kajetan; Petrovitch, Alexander; von Oldenburg, Geert; Hofmann, Gunther O
2008-03-01
Retrograde intramedullary nailing is an established procedure for tibiotalocalcaneal arthrodesis. The goal of this study was to evaluate the effects of angle-stable locking or compressed angle-stable locking on the initial stability of the nails and on the behavior of the constructs under cyclic loading conditions. Tibiotalocalcaneal arthrodesis was performed in fifteen third-generation synthetic bones and twenty-four fresh-frozen cadaver legs with use of retrograde intramedullary nailing with three different locking modes: a Stryker nail with compressed angle-stable locking, a Stryker nail with angle-stable locking, and a statically locked Biomet nail. Analyses were performed of the initial stability of the specimens (range of motion) and the laxity of the constructs (neutral zone) in dorsiflexion/plantar flexion, varus/valgus, and external rotation/internal rotation. Cyclic testing up to 100,000 cycles was also performed. The range of motion and the neutral zone in dorsiflexion/plantar flexion at specific cycle increments were determined. In both bone models, the intramedullary nails with compressed angle-stable locking and those with angle-stable locking were significantly superior, in terms of a smaller range of motion and neutral zone, to the statically locked nails. The compressed angle-stable nails were superior to the angle-stable nails only in the synthetic bone model, in external/internal rotation. Cyclic testing showed the nails with angle-stable locking and those with compressed angle-stable locking to have greater stability in both models. In the synthetic bone model, compressed angle-stable locking was significantly better than angle-stable locking; in the cadaver bone model, there was no significant difference between these two locking modes. During cyclic testing, five statically locked nails in the cadaver bone model failed, whereas one nail with angle-stable locking and one with compressed angle-stable locking failed. Regardless of the bone model, the nails with angle-stable or compressed angle-stable locking had better initial stability and better stability following cycling than did the nails with static locking.
A Biomechanical Comparison of Distal Fixation for Bridge Plating in a Distal Radius Fracture Model.
Alluri, Ram K; Bougioukli, Sofia; Stevanovic, Milan; Ghiassi, Alidad
2017-09-01
To compare the biomechanical properties of second versus third metacarpal distal fixation when using a radiocarpal spanning distraction plate in an unstable distal radius fracture model. Biomechanical evaluation of the radiocarpal spanning distraction plate comparing second versus third metacarpal distal fixation was performed using a standardized model of an unstable wrist fracture in 10 matched-pair cadaveric specimens. Each fixation construct underwent a controlled cyclic loading protocol in flexion and extension. The resultant displacement and stiffness were calculated at the fracture site. After cyclic loading, each specimen was loaded to failure. The stiffness, maximum displacement, and load to failure were compared between the 2 groups. Cyclic loading in flexion demonstrated that distal fixation to the third metacarpal resulted in greater stiffness compared with the second metacarpal. There was no significant difference between the 2 groups with regards to maximum displacement at the fracture site in flexion. Cyclic loading in extension demonstrated no significant difference in stiffness or maximum displacement between the 2 groups. The average load to failure was similar for both groups. Fixation to the third metacarpal resulted in greater stiffness in flexion. All other biomechanical parameters were similar when comparing distal fixation to the second or third metacarpal in distal radius fractures stabilized with a spanning internal distraction plate. The treating surgeon should choose distal metacarpal fixation primarily based on fracture pattern, alignment, and soft tissue integrity. If a stiffer construct is desired, placement of the radiocarpal spanning plate at the third metacarpal is preferred. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Comparison of dominant hand range of motion among throwing types in baseball pitchers.
Wang, Lin-Hwa; Kuo, Li-Chieh; Shih, Sheng-Wen; Lo, Kuo-Cheng; Su, Fong-Chin
2013-08-01
Previous research on baseball pitchers' wrists, elbows, and should joints contributes to our understanding of pitchers' control over delicate joint motion and ball release. However, limited research on forearm, wrist, and hand joints prevents full comprehension of the throwing mechanism. The present descriptive laboratory study quantifies angular performances of hand and wrist joints while pitching breaking balls, including fastballs, curveballs and sliders, among pitchers with different skill levels. Nineteen baseball pitchers performed required pitching tasks (10 from university and 9 from high school). A three-dimensional motion analysis system collected pitching motion data. The range of joint motion in the wrist and proximal interphalangeal (PIP) and metacarpophalangeal (MP) joints of the index and middle fingers were compared among fastballs, curveballs and sliders. Thirteen reflective markers were placed on selected anatomic landmarks of the wrist, middle and index fingers of the hand. Wrist flexion angle in the pitching acceleration phase was larger in fastballs (20.58±4.07°) and sliders (22.48±5.45°) than in curveballs (9.08±3.03°) (p = .001). The flexion angle of the PIP joint was significantly larger in curveballs (38.5±3.8°) than in fastballs (30.3±4.8°) and sliders (30.2±4.5°) (p=.004) of the middle finger. Abduction angle of MP joint on the middle finger was significantly larger in curveballs (15.4 ±3.6°) than in fastballs (8.9±1.2°) and sliders (6.9±2.9°) (p=.001) of the middle finger, and the abduction angle of index finger was significantly larger in sliders (13.5±15.0°) than in fastballs (7.2 ±2.8°) (p=.007). Hand and wrist motion and grip types affect the relative position between fingers and ball, which produces different types of baseball pitches. A larger extension angle of the wrist joint and the coordination of middle and index fingers are crucial when pitching a fastball. Abduction and flexion movement on the MP joint of the middle finger are important for a curveball. MP joint abduction and flexion movement of the index finger produce sliders. Understanding the control mechanism in a throwing hand can help improve training protocols in either injury prevention or performance improvement for baseball pitchers. Copyright © 2013 Elsevier B.V. All rights reserved.
Knee Biomechanics During Jogging After Arthroscopic Partial Meniscectomy: A Longitudinal Study.
Hall, Michelle; Wrigley, Tim V; Metcalf, Ben R; Hinman, Rana S; Cicuttini, Flavia M; Dempsey, Alasdair R; Lloyd, David G; Bennell, Kim L
2017-07-01
Altered knee joint biomechanics is thought to play a role in the pathogenesis of knee osteoarthritis and has been reported in patients after arthroscopic partial meniscectomy (APM) while performing various activities. Longitudinally, understanding knee joint biomechanics during jogging may assist future studies to assess the implications of jogging on knee joint health in this population. To investigate knee joint biomechanics during jogging in patients 3 months after APM and a healthy control group at baseline and 2 years later at follow-up. Controlled laboratory study. Seventy-eight patients who underwent medial APM and 38 healthy controls underwent a 3-dimensional motion analysis during barefoot overground jogging at baseline. Sixty-four patients who underwent APM and 23 controls returned at follow-up. External peak moments (flexion and adduction) and the peak knee flexion angle during stance were evaluated for the APM leg, non-APM leg (nonoperated leg), and control leg. At baseline, the peak knee flexion angle was 1.4° lower in the APM leg compared with the non-APM leg ( P = .03). No differences were found between the moments in the APM leg compared with the control leg (all P > .05). However, the normalized peak knee adduction moment was 35% higher in the non-APM leg compared with the control leg ( P = .008). In the non-APM leg, the normalized peak knee adduction and flexion moments were higher compared with the APM leg by 16% and 10%, respectively, at baseline ( P ≤ .004). Despite the increase in the peak knee flexion moment in the APM leg compared with the non-APM leg ( P < .001), there were no differences in the peak knee flexion moment or any other parameter assessed at 2-year follow-up between the legs ( P > .05). Comparing the APM leg and control leg, no differences in knee joint biomechanics during jogging for the variables assessed were observed. Higher knee moments in the non-APM leg may have clinical implications for the noninvolved leg. Kinematic differences were small (~1.4°) and therefore of questionable clinical relevance. These results may facilitate future clinical research regarding the implications of jogging on knee joint health in middle-aged, overweight patients after APM.
External Versus Two Different Internal Foci of Attention in Long-Distance Throwing.
Oki, Yuta; Kokubu, Masahiro; Nakagomi, Shiro
2018-02-01
The present study examined the influence of attentional focus on performance during a long-distance throwing task. Twelve participants executed three maximum-effort, long-distance baseball throwing attempts in three focus conditions: internal focus on wrist flexion (wrist internal focus), internal focus on the separation between pelvis and upper torso orientations (torso internal focus), and external focus on the ball path (external focus). Compared with the external focus and torso internal focus conditions, performance was poorer in the wrist internal focus condition. Performances were not different in the torso internal and external focus conditions. In addition, attentional focus affected the release angle of the ball but not its initial velocity. Our results reveal that the body part targeted for internal focus of attention and the forcefulness of the motor activity can be as important to motor performance as whether the attention is internal or external.
McCarthy, Moira M.; Tucker, Scott; Nguyen, Joseph T.; Green, Daniel W.; Imhauser, Carl W.; Cordasco, Frank A.
2014-01-01
Background Anterior cruciate ligament (ACL) injuries are an increasingly recognized problem in the pediatric population. Unfortunately, outcomes with conservative treatment are extremely poor. Furthermore, adult reconstruction techniques may be inappropriate to treat skeletally immature patients due to the risk of physeal complications. “Physeal-sparing” reconstruction techniques exist but their ability to restore knee stability and contact mechanics is not well understood. Purpose (1) To assess the ability of the all-epiphyseal (AE) and over-the-top (OT) reconstructions to restore knee kinematics; (2) to assess whether these reconstructions decrease the high posterior contact stresses seen with ACL deficiency; (3) to determine whether the AE or OT produce abnormal tibiofemoral contact stresses. Hypothesis The AE reconstruction will restore contact mechanics and kinematics similarly to that of the ACL intact knee. Methods Ten fresh-frozen human cadaveric knees were tested using a robotic manipulator. Tibiofemoral motions were recorded with the ACL intact, after sectioning the ACL, and after both reconstructions in each of the 10 specimens. The AE utilized an all-inside technique with tunnels exclusively within the epiphysis and fixed with suspensory cortical fixation devices. The OT had a central and vertical tibial tunnel with an over-the-top femur position and was fixed with staples and posts on both ends. Anterior stability was assessed with 134N anterior force at 0, 15, 30, 60, and 90° of knee flexion. Rotational stability was assessed with combined 8 Nm and 4 Nm of abduction and internal rotation, respectively, at 5, 15, and 30° of knee flexion. Results Both reconstruction techniques offloaded the posterior aspect of the tibial plateau compared to the ACL deficient knee in response to both anterior loads and combined moments as demonstrated by reduced contact stresses in this region at all flexion angles. Compared to the ACL intact condition, both the AE and OT had increased posteromedial contact stresses in response to anterior load at some flexion angles and the OT had increased peripheral posterolateral contact stresses at 15° in response to combined moments. Neither reconstruction completely restored the mid-joint contact stresses. Both reconstruction techniques restored anterior stability at flexion angles less than or equal to 30°. In contrast, neither reconstruction restored anterior stability at 60 and 90° flexion. Both reconstructions restored coupled anterior translation under combined moments. Additionally, the AE over-constrained internal rotation in response to the combined moments by 12% at 15° flexion. Conclusions Both reconstructions provide anterior and rotational stability, and decrease posterior joint contact stresses compared to the ACL deficient knee. However, neither reconstruction restored the contact mechanics and kinematics of the ACL intact knee. Clinical Relevance Since the AE reconstruction has clinical advantages over the OT, our results support the hypothesis that the new AE technique is a potential candidate for use in the skeletally immature athlete. PMID:23613444
Influence of snow shovel shaft configuration on lumbosacral biomechanics during a load-lifting task.
Lewinson, Ryan T; Rouhi, Gholamreza; Robertson, D Gordon E
2014-03-01
Lower-back injury from snow shovelling may be related to excessive joint loading. Bent-shaft snow shovels are commonly available for purchase; however, their influence on lower back-joint loading is currently not known. Therefore, the purpose of this study was to compare L5/S1 extension angular impulses between a bent-shaft and a standard straight-shaft snow shovel. Eight healthy subjects participated in this study. Each completed a simulated snow-lifting task in a biomechanics laboratory with each shovel design. A standard motion analysis procedure was used to determine L5/S1 angular impulses during each trial, as well as peak L5/S1 extension moments and peak upper body flexion angle. Paired-samples t-tests (α = 0.05) were used to compare variables between shovel designs. Correlation was used to determine the relationship between peak flexion and peak moments. Results of this study show that the bent-shaft snow shovel reduced L5/S1 extension angular impulses by 16.5% (p = 0.022), decreased peak moments by 11.8% (p = 0.044), and peak flexion by 13.0% (p = 0.002) compared to the straight-shaft shovel. Peak L5/S1 extension moment magnitude was correlated with peak upper body flexion angle (r = 0.70). Based on these results, it is concluded that the bent-shaft snow shovel can likely reduce lower-back joint loading during snow shovelling, and thus may have a role in snow shovelling injury prevention. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.
McGovern, Andrew; Dude, Christopher; Munkley, Daniel; Martin, Thomas; Wallace, David; Feinn, Richard; Dione, Donald; Garbalosa, Juan C
2015-12-01
Despite the recent emphasis on injury prevention, anterior cruciate ligament (ACL) injury rates remain high. This study aimed to ascertain the effects of prolonged activity on lower limb kinematics during a self-selected cutting maneuver. Angular kinematics were recorded during an agility test performed until the completion time was greater than the mean plus one SD of baseline trials. Cut type was identified and the hip and knee angles at 33 ms post heel strike were determined. A linear mixed effects model assessed the effects of cut type, gender, and activity status on the hip and knee angles. Males performed sidestep cuts more frequently than females. Females increased the incidence of sidestep cuts after prolonged activity. At the hip, a gender-cut type interaction existed for the transverse (p=0.001) and sagittal (p=0.11) planes. Females showed more internal rotation during sidestep and more external rotation and less flexion during crossover cuts. For the frontal plane, a gender-activity status interaction (p = 0.032) was due to no change within females but greater hip adduction during prolonged activity within males. With prolonged activity, both genders displayed less hip (p=0.29) and knee (p=0.009) flexion and more knee (p=0.001) adduction. Females displayed less hip and knee flexion than men (p=0.001). Sidestep may be more risky than crossover cuts. Both genders place themselves in at-risk postures with prolonged activity due to less hip and knee flexion. Copyright © 2015 Elsevier B.V. All rights reserved.
Kim, Jae-Woong; Kwon, Moon-Seok; Yenuga, Sree Sushma; Kwon, Young-Hoooo
2010-06-01
The study purpose was to investigate the effects of target distance on pivot hip, trunk, pelvis, and kicking leg movements in Taekwondo roundhouse kick. Twelve male black-belt holders executed roundhouse kicks for three target distances (Normal, Short, and Long). Linear displacements of the pivot hip and orientation angles of the pelvis, trunk, right thigh, and right shank were obtained through a three-dimensional video motion analysis. Select displacements, distances, peak orientation angles, and angle ranges were compared among the conditions using one-way repeated measure ANOVA (p < 0.05). Several orientation angle variables (posterior tilt range, peak right-tilted position, peak right-rotated position, peak left-rotated position, and left rotation range of the pelvis; peak hyperextended position and peak right-flexed position of the trunk; peak flexed position, flexion range and peak internal-rotated position of the hip) as well as the linear displacements of the pivot hip and the reach significantly changed in response to different target distances. It was concluded that the adjustment to different target distances was mainly accomplished through the pivot hip displacements, hip flexion, and pelvis left rotation. Target distance mainly affected the reach control function of the pelvis and the linear balance function of the trunk.
Age and sex influences on running mechanics and coordination variability.
Boyer, Katherine A; Freedman Silvernail, Julia; Hamill, Joseph
2017-11-01
The purpose of this study was to examine the impact of age on running mechanics separately for male and female runners and to quantify sex differences in running mechanics and coordination variability for older runners. Kinematics and kinetics were captured for 20 younger (10 male) and 20 older (10 male) adults running overground at 3.5 m · s -1 . A modified vector coding technique was used to calculate segment coordination variability. Lower extremity joint angles, moments and segment coordination variability were compared between age and sex groups. Significant sex-age interaction effects were found for heel-strike hip flexion and ankle in/eversion angles and peak ankle dorsiflexion angle. In older adults, mid-stance knee flexion angle, ankle inversion and abduction moments and hip abduction and external rotation moments differed by sex. Older compared with younger females had reduced coordination variability in the thigh-shank transverse plane couple but greater coordination variability for the shank rotation-foot eversion couple in early stance. These results suggest there may be a non-equivalent aging process in the movement mechanics for males and females. The age and sex differences in running mechanics and coordination variability highlight the need for sex-based analyses for future studies examining injury risk with age.
Analysis of the 5 iron golf swing when hitting for maximum distance.
Healy, Aoife; Moran, Kieran A; Dickson, Jane; Hurley, Cillian; Smeaton, Alan F; O'Connor, Noel E; Kelly, Philip; Haahr, Mads; Chockalingam, Nachiappan
2011-07-01
Most previous research on golf swing mechanics has focused on the driver club. The aim of this study was to identify the kinematic factors that contribute to greater hitting distance when using the 5 iron club. Three-dimensional marker coordinate data were collected (250 Hz) to calculate joint kinematics at eight key swing events, while a swing analyser measured club swing and ball launch characteristics. Thirty male participants were assigned to one of two groups, based on their ball launch speed (high: 52.9 ± 2.1 m · s(-1); low: 39.9 ± 5.2 m · s(-1)). Statistical analyses were used to identify variables that differed significantly between the two groups. Results showed significant differences were evident between the two groups for club face impact point and a number of joint angles and angular velocities, with greater shoulder flexion and less left shoulder internal rotation in the backswing, greater extension angular velocity in both shoulders at early downswing, greater left shoulder adduction angular velocity at ball contact, greater hip joint movement and X Factor angle during the downswing, and greater left elbow extension early in the downswing appearing to contribute to greater hitting distance with the 5 iron club.
Hasan, Hosni; Davids, Keith; Chow, Jia Yi; Kerr, Graham
2017-04-01
This study investigated effects of wearing compression garments and textured insoles on modes of movement organisation emerging during performance of lower limb interceptive actions in association football. Participants were six skilled (age = 15.67 ± 0.74 years) and six less-skilled (age = 15.17 ± 1.1 years) football players. All participants performed 20 instep kicks with maximum velocity in four randomly organised insoles and socks conditions, (a) Smooth Socks with Smooth Insoles (SSSI); (b) Smooth Socks with Textured Insoles (SSTI); (c) Compression Socks with Smooth Insoles (CSSI); and (d), Compression Socks with Textured Insoles (CSTI). Results showed that, when wearing textured and compression materials (CSSI condition), less-skilled participants displayed significantly greater hip extension and flexion towards the ball contact phase, indicating larger ranges of motion in the kicking limb than in other conditions. Less-skilled participants also demonstrated greater variability in knee-ankle intralimb (angle-angle plots) coordination modes in the CSTI condition. Findings suggested that use of textured and compression materials increased attunement to somatosensory information from lower limb movement, to regulate performance of dynamic interceptive actions like kicking, especially in less-skilled individuals.
Core strength and lower extremity alignment during single leg squats.
Willson, John D; Ireland, Mary Lloyd; Davis, Irene
2006-05-01
Muscles of the trunk, hip, and knee influence the orientation of the lower extremity during weight bearing activities. The purpose of this study was threefold: first, to compare the orientation of the lower extremity during a single leg (SL) squat among male and female athletes; second, to compare the strength of muscle groups in the trunk, hips, and knees between these individuals; and third, to evaluate the association between trunk, hip, and knee strength and the orientation of the knee joint during this activity. Twenty-four male and 22 female athletes participated in this study. Peak isometric torque was determined for the following muscle actions: trunk flexion, extension, and lateral flexion, hip abduction and external rotation, and knee flexion and extension. The frontal plane projection angle (FPPA) of the knee during a 45 degrees SL squat was determined using photo editing software. Males and females moved in opposite directions during the SL squat test (F(1,42) = 5.05, P = 0.03). Females typically moved toward more extreme FPPA during SL squats (P = 0.056), while males tended to move toward more neutral alignment (P = 0.066). Females also generated less torque in all muscle groups, with the exception of trunk extension. The projection angle of the knee during the SL squat test was most closely associated with hip external rotation strength. Using instruments suitable for a clinical setting, females were found to have greater FPPA and generally decreased trunk, hip, and knee isometric torque. Hip external rotation strength was most closely associated with the frontal plane projection angle.
Alves de Araújo, Maria Erivânia; Bezerra da Silva, Elirez; Bragade Mello, Danielli; Cader, Samária Ali; Shiguemi Inoue Salgado, Afonso; Dantas, Estélio Henrique Martin
2012-04-01
To evaluate the effectiveness of Pilates with regard to the degree of scoliosis, flexibility and pain. The study included 31 female students divided into two groups: a control group (CG = 11), which had no therapeutic intervention, and an experimental group (EG = 20), which underwent Pilates-based therapy. We used radiological goniometry measurements to assess the degree of scoliosis, standard goniometry measurements to determine the degree of flexibility and the scale of perceived pain using the Borg CR 10 to quantify the level of pain. The independent t test of the Cobb angle (t = - 2.317, p = 0.028), range of motion of trunk flexion (t = 3.088, p = 0.004) and pain (t = -2.478, p = 0.019) showed significant differences between the groups, with best values in the Pilates group. The dependent t test detected a significant decrease in the Cobb angle (Δ% = 38%, t = 6.115, p = 0.0001), a significant increase in trunk flexion (Δ% = 80%, t = -7.977, p = 0.0001) and a significant reduction in pain (Δ% = 60%, t = 7.102, p = 0.0001) in the EG. No significant difference in Cobb angle (t = 0.430, p = 0.676), trunk flexion, (t = 0.938p = 0.371) or pain (t = 0.896, p = 0.391) was found for the CG. The Pilates group was better than control group. The Pilates method showed a reduction in the degree of non-structural scoliosis, increased flexibility and decreased pain. Copyright © 2011 Elsevier Ltd. All rights reserved.
Serial casting for elbow flexion contractures in neonatal brachial plexus palsy.
Duijnisveld, B J; Steenbeek, D; Nelissen, R G H H
2016-09-02
The objective of this study was to evaluate the effectiveness of serial casting of elbow flexion contractures in neonatal brachial plexus palsy. A prospective consecutive cohort study was performed with a median follow-up of 5 years. Forty-one patients with elbow flexion contractures ≥ 30° were treated with serial casting until the contracture was ≤ 10°, for a maximum of 8 weeks. Range of motion, number of recurrences and patient satisfaction were recorded and analyzed using Wilcoxon signed-rank and Cox regression tests. Passive extension increased from a median of -40° (IQR -50 to -30) to -15° (IQR -10 to -20, p < 0.001). Twenty patients showed 37 recurrences. The baseline severity of passive elbow extension had a hazard ratio of 0.93 (95% CI 0.89 to 0.96, p < 0.001) for first recurrence. Median patient satisfaction was moderate. Four patients showed loss of flexion mobility and in two patients serial casting had to be prematurely replaced by night splinting due to complaints. Serial casting improved elbow flexion contractures, although recurrences were frequent. The severity of elbow flexion contracture is a predictor of recurrence. We recommend more research on muscle degeneration and determinants involved in elbow flexion contractures to improve treatment strategies and prevent side-effects.
Body size and lower limb posture during walking in humans
Hora, Martin; Soumar, Libor; Pontzer, Herman; Sládek, Vladimír
2017-01-01
We test whether locomotor posture is associated with body mass and lower limb length in humans and explore how body size and posture affect net joint moments during walking. We acquired gait data for 24 females and 25 males using a three-dimensional motion capture system and pressure-measuring insoles. We employed the general linear model and commonality analysis to assess the independent effect of body mass and lower limb length on flexion angles at the hip, knee, and ankle while controlling for sex and velocity. In addition, we used inverse dynamics to model the effect of size and posture on net joint moments. At early stance, body mass has a negative effect on knee flexion (p < 0.01), whereas lower limb length has a negative effect on hip flexion (p < 0.05). Body mass uniquely explains 15.8% of the variance in knee flexion, whereas lower limb length uniquely explains 5.4% of the variance in hip flexion. Both of the detected relationships between body size and posture are consistent with the moment moderating postural adjustments predicted by our model. At late stance, no significant relationship between body size and posture was detected. Humans of greater body size reduce the flexion of the hip and knee at early stance, which results in the moderation of net moments at these joints. PMID:28192522
Intraarticular arthrofibrosis of the knee alters patellofemoral contact biomechanics.
Mikula, Jacob D; Slette, Erik L; Dahl, Kimi D; Montgomery, Scott R; Dornan, Grant J; O'Brien, Luke; Turnbull, Travis Lee; Hackett, Thomas R
2017-12-19
Arthrofibrosis in the suprapatellar pouch and anterior interval can develop after knee injury or surgery, resulting in anterior knee pain. These adhesions have not been biomechanically characterized. The biomechanical effects of adhesions in the suprapatellar pouch and anterior interval during simulated quadriceps muscle contraction from 0 to 90° of knee flexion were assessed. Adhesions of the suprapatellar pouch and anterior interval were hypothesized to alter the patellofemoral contact biomechanics and increase the patellofemoral contact force compared to no adhesions. Across all flexion angles, suprapatellar adhesions increased the patellofemoral contact force compared to no adhesions by a mean of 80 N. Similarly, anterior interval adhesions increased the contact force by a mean of 36 N. Combined suprapatellar and anterior interval adhesions increased the mean patellofemoral contact force by 120 N. Suprapatellar adhesions resulted in a proximally translated patella from 0 to 60°, and anterior interval adhesions resulted in a distally translated patella at all flexion angles other than 15° (p < 0.05). The most important finding in this study was that patellofemoral contact forces were significantly increased by simulated adhesions in the suprapatellar pouch and anterior interval. Anterior knee pain and osteoarthritis may result from an increase in patellofemoral contact force due to patellar and quadriceps tendon adhesions. For these patients, arthroscopic lysis of adhesions may be beneficial.
Lower-limb kinematics of single-leg squat performance in young adults.
Horan, Sean A; Watson, Steven L; Carty, Christopher P; Sartori, Massimo; Weeks, Benjamin K
2014-01-01
To determine the kinematic parameters that characterize good and poor single-leg squat (SLS) performance. A total of 22 healthy young adults free from musculoskeletal impairment were recruited for testing. For each SLS, both two-dimensional video and three-dimensional motion analysis data were collected. Pelvis, hip, and knee angles were calculated using a reliable and validated lower-limb (LL) biomechanical model. Two-dimensional video clips of SLSs were blindly assessed in random order by eight musculoskeletal physiotherapists using a 10-point ordinal scale. To facilitate between-group comparisons, SLS performances were stratified by tertiles corresponding to poor, intermediate, and good SLS performance. Mean ratings of SLS performance assessed by physiotherapists were 8.3 (SD 0.5), 6.8 (SD 0.7), and 4.0 (SD 0.8) for good, intermediate, and poor squats, respectively. Three-dimensional analysis revealed that people whose SLS performance was assessed as poor exhibited increased hip adduction, reduced knee flexion, and increased medio-lateral displacement of the knee joint centre compared to those whose SLS performance was assessed as good (p≤0.05). Overall, poor SLS performance is characterized by inadequate knee flexion and excessive frontal plane motion of the knee and hip. Future investigations of SLS performance should consider standardizing knee flexion angle to illuminate other influential kinematic parameters.
Fetlock joint kinematics differ with age in Thoroughbred [was thoroughbred] racehorses.
Butcher, Michael T; Ashley-Ross, M A
2002-05-01
Fetlock joint kinematics during galloping in 2-, 3-, 4-, and 5-year-old Thoroughbreds in race training were quantified to determine if differences due to age could account for the observation that 2-year old Thoroughbred racehorses incur a high number of injuries to the bones and soft tissues in the distal forelimbs during training and at the outset of racing. Twelve Thoroughbred racehorses were videotaped in the sagittal plane at 250 frames/s during their daily galloping workout on a 7/8 mile sand-surface training track. Four galloping strides were recorded for each horse and subsequently digitized to determine fetlock joint angles of the leading forelimb during the limb support period of a stride. Four kinematic variables were measured from each stride's angular profile: angle of fetlock joint dorsi-flexion at mid-stance, negative angular velocity, positive angular velocity and time from hoof impact to mid-stance phase of limb support. The 2-year old Thoroughbreds had significantly quicker rates of dorsi-flexion of their fetlock joints than 3- (p=0.01), 4- (p=0.01), and 5-year old (p<0.01) Thoroughbreds following impact of the leading forelimb during moderate galloping (avg. 14 m/s). Higher rates of dorsi-flexion in young Thoroughbreds may reflect immaturity (lack of stiffness) of the suspensory apparatus tissues.
Pressure-volume relationships and elastance in the knee joint of the dog.
Nade, S; Newbold, P J
1984-12-01
This study has investigated changes in intra-articular hydrostatic pressure in the knee joints of normal dogs in response to continuous and stepwise infusions of fluids. The relationship between pressure and volume in the joint was examined over the pressure range of -8 to +50 mmHg, and also at much higher pressures often associated with joint disease or injury. The effects of joint angle and dog weight on the pressure-volume relationship and on elastance of the dogs' knees were also examined. With liquid paraffin B.P. the pressure was found to increase more with each unit volume infused at subatmospheric pressures than at pressures around atmospheric, and increased more again at higher pressures. The pressure-volume curve with saline infusions was affected by egress of fluid from the joint at supra-atmospheric pressure. Above +5 mmHg the rise in pressure per unit volume infused was less than that for paraffin at the same volume. Elastance and compliance of the normal joint capsule were calculated from the pressure-volume data. Elastance was high at subatmospheric pressures, decreased rapidly as atmospheric pressure was approached and rose as a linear function of pressure above 12 mmHg. The biphasic shape of the elastance-pressure curve is discussed, and explanations for the shape are suggested. After intra-articular pressure in the knee was raised by infusion of paraffin oil the joint was moved through the range of positions from 125 deg extension to 50 deg flexion. Intra-articular pressure did not change across the range 125-110 deg. However, increasing the angle of flexion from 110 to 50 deg resulted in a rise in pressure which became steeper for each volume increment. Increasing intra-articular fluid volume caused a decrease in the total range of movement of the joint. The pressure-volume curves measured at extended angles of 110, 125 and 140 deg, where the starting pressures were subatmospheric, were the same. At flexed joint positions of 80 and 50 deg, where the starting pressures were supra-atmospheric, the pressure-volume curves became steeper with greater flexion. Elastance of the joint tissues increased with flexion. The elastance at each joint angle depended also on the volume or pressure. Significant differences were found to exist between pressure-volume curves for three groups of animals of different weight.(ABSTRACT TRUNCATED AT 400 WORDS)
Soft-tissue tension total knee arthroplasty.
Asano, Hiroshi; Hoshino, Akiho; Wilton, Tim J
2004-08-01
It is far from clear how best to define the proper strength of soft-tissue tensioning in total knee arthroplasty (TKA). We attached a torque driver to the Monogram balancer/tensor device and measured soft-tissue tension in full extension and 90 degrees flexion during TKA. In our surgical procedure, when we felt proper soft-tissue tension was being applied, the mean distraction force was noted to be 126N in extension and 121N in flexion. There was no significant correlation between soft-tissue tension and the postoperative flexion angle finally achieved. To the best of our knowledge, this is the first study to assess the actual distraction forces in relation to soft-tissue tension in TKA. Further study may reveal the most appropriate forces to achieve proper soft-tissue tension in the wide variety of circumstances presenting at knee arthroplasty.
Does patella position influence ligament balancing in total knee arthroplasty?
Yoon, Jung-Ro; Oh, Kwang-Jun; Wang, Joon Ho; Yang, Jae-Hyuk
2015-07-01
In vivo comparative gap measurements were performed in three different patella positions (reduced, subluxated and everted) using offset-type-force-controlled-spreader-system. Prospectively, 50 knees were operated by total knee arthroplasty using a navigation-assisted gap-balancing technique. The offset-type-force-controlled-spreader-system was used for gap measurements. This commercially available instrument allows controllable tension in patella-reduced position. The mediolateral gaps of knee extension (0°) and flexion (90°) angle were recorded in three different patella positions; reduced, subluxated and everted. Any gap differences of more than 3 mm were considered as a meaningful difference. Correlation between the difference with the demographic data, preoperative radiologic alignment and intraoperative data was analysed. For statistical analysis, ANOVA and Pearson's correlation test were used. The gaps in patella eversion demonstrated smaller gaps both in knee extension and flexion position compared to the gaps of patella reduction position. The amount of decreased gaps was more definite in knee flexion position. Statistically significant difference was observed for the lateral gap of patella eversion compared to gap of patella reduction in knee flexion position (p < 0.05). There were notable cases of variability in knee flexion position. Significant portion of 12 (24 %) knees of patella subluxation and 33 (66 %) knees of patella evertion demonstrated either increased or decreased gaps in knee flexion position compared to the gaps of patella reduction position. The gaps in patella eversion demonstrated smaller gaps both in knee extension and flexion position compared to the gaps of patella reduction position. The amount of decreased gaps was more definite in knee flexion position. Therefore, the intraoperative patellar positioning has influence on the measurement of the joint gap. Keeping the patella in reduced position is important during gap balancing. I.
Effect of posterior cruciate ligament rupture on the radial displacement of lateral meniscus.
Lei, Pengfei; Sun, Rongxin; Hu, Yihe; Li, Kanghua; Liao, Zhan
2015-06-01
The relationship between lateral meniscus tear and posterior cruciate ligament injury is not well understood. The present study aims to investigate and assess the effect of posterior cruciate ligament rupture on lateral meniscus radial displacement at different flexion angles under static loading conditions. Twelve fresh human cadaveric knee specimens were divided into four groups such as posterior cruciate ligament intact, anterolateral band rupture, posteromedial band rupture and posterior cruciate ligament complete rupture groups, according to the purpose and order of testing. Radial displacement of lateral meniscus was measured under different loads (200-1000N) at 0°, 30°, 60°, and 90° of knee flexion. Compared with posterior cruciate ligament intact group, the displacement values of lateral meniscus in anterolateral band rupture group increased at 0° flexion with 600N, 800N, and 1000N and at 30°, 60° and 90° flexion under all loading conditions. Posteromedial band rupture group exhibited higher displacement at 0° flexion under all loading conditions, at 30° and 60° flexion with 600, 800N and 1000N, and at 90° flexion with 400N, 600N, 800N, and 1000N than the posterior cruciate ligament intact group. The posterior cruciate ligament complete rupture group had a higher displacement value of lateral medial meniscus at 0°, 30°, 60° and 90° flexion under all loading conditions, as compared to the posterior cruciate ligament intact group. The study concludes that partial and complete rupture of the posterior cruciate ligament can trigger the increase of radial displacement on lateral meniscus. Copyright © 2015 Elsevier Ltd. All rights reserved.
Shui, Xiaolong; Ying, Xiaozhou; Kong, Jianzhong; Feng, Yongzeng; Hu, Wei; Guo, Xiaoshan; Wang, Gang
2015-08-01
Our objective was to measure the sagittal plane rotational (flexion and extension) displacement of hemipelvis radiologically and analyze the ratio of flexion and extension displacement of unstable pelvic fractures. We used 8 cadaveric models to study the radiographic evidence of pelvic fractures in the sagittal plane. We performed pelvic osteotomy on 8 cadavers to simulate anterior and posterior pelvic ring injury. Radiological data were measured in the flexion and extension group under different angles (5°, 10°, 15°, 20°, and 25°). We retrospectively reviewed 164 patients who were diagnosed with a unilateral fracture of the pelvis. Pelvic ring displacement was identified and recorded radiographically in cadaveric models. The flexion and extension displacement of pelvic fractures was measured in terms of the vertical distance of fracture from the top of iliac crest to the pubic tubercle (CD) or from the top of iliac crest to the lowest point of ischial tuberosity (AB). Fifty-seven pelves showed flexion displacement and 15 showed extension displacement. Closed reduction including internal fixation and external fixation was successfully used in 141 cases (86.0 %). The success rates of closed reduction in flexion and extension displacement groups were 77 and 73 %, respectively, which were lower than in unstable pelvic ring fractures. The sagittal plane rotation (flexion and extension) displacement of pelvic fractures could be measured by special points and lines on the radiographs. Minimally invasive reduction should be based on clearly identified differences between the sagittal plane rotation and the vertical displacement of pelvic fractures.
Scuderi, Giles R; Hedden, David R; Maltry, John A; Traina, Steven M; Sheinkop, Mitchell B; Hartzband, Mark A
2012-03-01
Between May 2001 and June 2004, 388 total knee arthroplasty cases were enrolled in a prospective, randomized, multicenter investigational device exemption trial. Patients received either the investigational high-flexion mobile-bearing knee or a fixed-bearing control. At 2 to 4 years of follow-up, results in 293 patients with degenerative joint disease were compared using Knee Society Assessment and Function scores, radiographic results, complications analysis, and survival estimates. The mobile-bearing and fixed-bearing groups demonstrated similar, significant improvement over preoperative assessments in Knee Scores, maximum flexion, and range of motion. One mobile-bearing arthroplasty required revision. Radiographic results were unremarkable, and implant-related complications were rare in both groups. At this early follow-up, the investigational high-flexion mobile-bearing knee and its fixed-bearing counterpart demonstrated comparable, effective performance. Copyright © 2012 Elsevier Inc. All rights reserved.
Pinsornsak, Piya; Harnroongroj, Thos
2016-11-01
The specialized instrument system used in minimally invasive surgery (MIS) has been developed for reducing soft tissue trauma in total knee arthroplasty (TKA). Compared with front-cutting MIS instruments, side-cutting quadriceps sparing MIS instruments have the advantage of creating a smaller incision and causing fewer traumas to the quadriceps tendon. However, the accuracy of side-cutting instruments concerns surgeons in prosthesis malalignment. To compare the accuracy of side-cutting quadriceps sparing instruments versus front-cutting instruments in MIS-TKA. In this prospective randomized controlled study, we compared the accuracy of side-cutting quadriceps sparing instruments versus the front-cutting instruments used in MIS-TKA. Sixty knees were included in the study, with 30 knees in each group. All the operations were performed by single surgeon. Coronal alignment (tibiofemoral angle, lateral distal femoral angle, and medial proximal tibial angle), and sagittal alignment (femoral component flexion and tibial posterior slope) were measured and compared. Tibiofemoral angle, lateral distal femoral angle, and medial proximal tibial angle, all of which are considered in the assessment of acceptable coronal radiographic alignment, were not different between groups (p = 0.353, 0.500, and 0.177, respectively). However, side-cutting quadriceps sparing instruments produced less acceptable sagittal radiographic alignment, femoral component flexion (63% vs. 93%, p = 0.005), and tibial posterior slope (73% vs. 93%, p = 0.04). Side-cutting quadriceps sparing MIS-TKA instruments had similar accuracy to front-cutting MIS-TKA instruments for coronal alignment but is less accurate for sagittal alignment.
Invariant hip moment pattern while walking with a robotic hip exoskeleton
Lewis, Cara L.; Ferris, Daniel P.
2011-01-01
Robotic lower limb exoskeletons hold significant potential for gait assistance and rehabilitation; however, we have a limited understanding of how people adapt to walking with robotic devices. The purpose of this study was to test the hypothesis that people reduce net muscle moments about their joints when robotic assistance is provided. This reduction in muscle moment results in a total joint moment (muscle plus exoskeleton) that is the same as the moment without the robotic assistance despite potential differences in joint angles. To test this hypothesis, eight healthy subjects trained with the robotic hip exoskeleton while walking on a force-measuring treadmill. The exoskeleton provided hip flexion assistance from approximately 33% to 53% of the gait cycle. We calculated the root mean squared difference (RMSD) between the average of data from the last 15 minutes of the powered condition and the unpowered condition. After completing three 30-minute training sessions, the hip exoskeleton provided 27% of the total peak hip flexion moment during gait. Despite this substantial contribution from the exoskeleton, subjects walked with a total hip moment pattern (muscle plus exoskeleton) that was almost identical and more similar to the unpowered condition than the hip angle pattern (hip moment RMSD 0.027, angle RMSD 0.134, p<0.001). The angle and moment RMSD were not different for the knee and ankle joints. These findings support the concept that people adopt walking patterns with similar joint moment patterns despite differences in hip joint angles for a given walking speed. PMID:21333995
Hajibozorgi, M; Arjmand, N
2016-04-11
Range of motion (ROM) of the thoracic spine has implications in patient discrimination for diagnostic purposes and in biomechanical models for predictions of spinal loads. Few previous studies have reported quite different thoracic ROMs. Total (T1-T12), lower (T5-T12) and upper (T1-T5) thoracic, lumbar (T12-S1), pelvis, and entire trunk (T1) ROMs were measured using an inertial tracking device as asymptomatic subjects flexed forward from their neutral upright position to full forward flexion. Correlations between body height and the ROMs were conducted. An effect of measurement errors of the trunk flexion (T1) on the model-predicted spinal loads was investigated. Mean of peak voluntary total flexion of trunk (T1) was 118.4 ± 13.9°, of which 20.5 ± 6.5° was generated by flexion of the T1 to T12 (thoracic ROM), and the remaining by flexion of the T12 to S1 (lumbar ROM) (50.2 ± 7.0°) and pelvis (47.8 ± 6.9°). Lower thoracic ROM was significantly larger than upper thoracic ROM (14.8 ± 5.4° versus 5.8 ± 3.1°). There were non-significant weak correlations between body height and the ROMs. Contribution of the pelvis to generate the total trunk flexion increased from ~20% to 40% and that of the lumbar decreased from ~60% to 42% as subjects flexed forward from upright to maximal flexion while that of the thoracic spine remained almost constant (~16% to 20%) during the entire movement. Small uncertainties (±5°) in the measurement of trunk flexion angle resulted in considerable errors (~27%) in the model-predicted spinal loads only in activities involving small trunk flexion. Copyright © 2015 Elsevier Ltd. All rights reserved.
Cheng, Xiaofei; Zhang, Feng; Wu, Jigong; Zhu, Zhenan; Dai, Kerong; Zhao, Jie
2016-08-15
A retrospective study. The aim of this study was to investigate the correlation between pelvic incidence (PI) and lumbar lordosis (LL) mismatch and knee flexion during standing in patients with lumbar degenerative diseases and to examine the effects of surgical correction of the PI-LL mismatch on knee flexion. Only several studies focused on knee flexion as a compensatory mechanism of the PI-LL mismatch. Little information is currently available on the effects of lumbar correction on knee flexion in patients with the PI-LL mismatch. A group of patients with lumbar degenerative diseases were divided into PI-LL match group (PI-LL ≤ 10°) and PI-LL mismatch group (PI-LL > 10°). A series of radiographic parameters and knee flexion angle (KFA) were compared between the two groups. The PI-LL mismatch group was further subdivided into operative and nonoperative group. The changes in KFA with PI-LL were examined. The PI-LL mismatch group exhibited significantly greater sagittal vertical axis (SVA), pelvic tilt (PT) and KFA, and smaller LL, thoracic kyphosis (TK), and sacral slope than the PI-LL match group. PI-LL, LL, PI, SVA, and PT were significantly correlated with KFA in the PI-LL mismatch group. From baseline to 6-month follow-up, all variables were significantly different in the operative group with the exception of PI, although there was no significant difference in any variable in the nonoperative group. The magnitude of surgical correction in the PI-LL mismatch was significantly correlated with the degree of spontaneous changes in KFA, PT, and TK. The PI-LL mismatch would contribute to compensatory knee flexion during standing in patients with lumbar degenerative disease. Surgical correction of the PI-LL mismatch could lead to a spontaneous improvement of compensatory knee flexion. The degree of improvement in knee flexion depends in part on the amount of correction in the PI-LL mismatch. 3.
Effect of Posture on Hip Angles and Moments during Gait
Lewis, Cara L.; Sahrmann, Shirley A.
2014-01-01
Anterior hip pain is common in young, active adults. Clinically, we have noted that patients with anterior hip pain often walk in a swayback posture, and that their pain is reduced when the posture is corrected. The purpose of this study was to investigate a potential mechanism for the reduction in pain by testing the effect of posture on movement patterns and internal moments during gait in healthy subjects. Fifteen subjects were instructed to walk while maintaining three postures: 1) natural, 2) swayback, and 3) forward flexed. Kinematic and force data were collected using a motion capture system and a force plate. Walking in the swayback posture resulted in a higher peak hip extension angle, hip flexor moment and hip flexion angular impulse compared to natural posture. In contrast, walking in a forward flexed posture resulted in a decreased hip extension angle and decreased hip flexion angular impulse. Based on these results, walking in a swayback posture may result in increased forces required of the anterior hip structures, potentially contributing to anterior hip pain. This study provides a potential biomechanical mechanism for clinical observations that posture correction in patients with hip pain is beneficial. PMID:25262565
Effect of posture on hip angles and moments during gait.
Lewis, Cara L; Sahrmann, Shirley A
2015-02-01
Anterior hip pain is common in young, active adults. Clinically, we have noted that patients with anterior hip pain often walk in a swayback posture, and that their pain is reduced when the posture is corrected. The purpose of this study was to investigate a potential mechanism for the reduction in pain by testing the effect of posture on movement patterns and internal moments during gait in healthy subjects. Fifteen subjects were instructed to walk while maintaining three postures: 1) natural, 2) swayback, and 3) forward flexed. Kinematic and force data were collected using a motion capture system and a force plate. Walking in the swayback posture resulted in a higher peak hip extension angle, hip flexor moment and hip flexion angular impulse compared to natural posture. In contrast, walking in a forward flexed posture resulted in a decreased hip extension angle and decreased hip flexion angular impulse. Based on these results, walking in a swayback posture may result in increased forces required of the anterior hip structures, potentially contributing to anterior hip pain. This study provides a potential biomechanical mechanism for clinical observations that posture correction in patients with hip pain is beneficial. Copyright © 2014 Elsevier Ltd. All rights reserved.
Park, Mi Hwa; Yu, Jae Ho; Hong, Ji Heon; Kim, Jin Seop; Jung, Sang Woo; Lee, Dong Yeop
2016-03-01
[Purpose] To date, core muscle activity detected using ultrasonography during prone bridge exercises has not been reported. Here we investigated the effects of core muscle thickness and balance on sling exercise efficacy by shoulder joint angle in healthy individuals. [Subjects and Methods] Forty-three healthy university students were enrolled in this study. Ultrasonography thickness of external oblique, internal oblique, and transversus abdominis during sling workouts was investigated. Muscle thickness was measured on ultrasonography imaging before and after the experiment. Dynamic balance was tested using a functional reaching test. Static balance was tested using a Tetrax Interactive Balance System. [Results] Different muscle thicknesses were observed during the prone bridge exercise with the shoulder flexed at 60°, 90° or 120°. Shoulder flexion at 60° and 90° in the prone bridge exercise with a sling generated the greatest thickness of most transversus abdominis muscles. Shoulder flexion at 120° in the prone bridge exercise with a sling generated the greatest thickness of most external oblique muscles. [Conclusion] The results suggest that the prone bridge exercise with shoulder joint angle is an effective method of increasing global and local muscle strength.
The influence of the test setup on knee joint kinematics - A meta-analysis of tibial rotation.
Hacker, Steffen P; Ignatius, Anita; Dürselen, Lutz
2016-09-06
The human knee is one of the most investigated joints in the human body. Various test setups exist to measure and analyse knee kinematics in vitro which differ in a wide range of parameters. The purpose of this article is to find an answer to the question if the test setup influences the kinematic outcome of studies and to what extend the results can be compared. To answer this question, we compared the tibial rotation as a function of flexion angle presented in 19 published studies. Raw data was extracted via image segmentation from the graphs depicted in these publications and the differences between the publications was analysed. Additionally, all test setups were compared regarding four aspects: method for angle calculation, system for data acquisition, loading condition and testing rig design. The resulting correlation matrix shows the influence of the test setup on the study outcome. Our results indicate that each study needs to collect its own reference data. Finally, we provide a mean internal rotation as a function of flexion angle based on more than 140 specimens tested in 14 different studies. Copyright © 2016 Elsevier Ltd. All rights reserved.
Biscarini, Andrea; Contemori, Samuele; Busti, Daniele; Botti, Fabio M; Pettorossi, Vito E
2016-12-08
Quadriceps strengthening exercises designed for the early phase of anterior cruciate ligament (ACL) rehabilitation should limit the anterior tibial translation developed by quadriceps contraction near full knee extension, in order to avoid excessive strain on the healing tissue. We hypothesize that knee-flexion exercises with simultaneous voluntary contraction of quadriceps (voluntary quadriceps cocontraction) can yield considerable levels of quadriceps activation while preventing the tibia from translating forward relative to the femur. Electromyographic activity in quadriceps and hamstring muscles was measured in 20 healthy males during isometric knee-flexion exercises executed near full knee extension with maximal voluntary effort of quadriceps cocontraction and external resistance (R) ranging from 0% to 60% of the 1-repetition maximum (1RM). Biomechanical modeling was applied to derive the shear (anterior/posterior) tibiofemoral force developed in each exercise condition. Isometric knee-flexion exercises with small external resistance (R=10% 1RM) and maximal voluntary effort of quadriceps cocontraction yielded a net posterior (ACL-unloading) tibial pull (P=0.005) and levels of activation of 32%, 50%, and 45% of maximum voluntary isometric contraction, for the rectus femoris, vastus medialis, and vastus lateralis, respectively. This exercise might potentially rank as one of the most appropriate quadriceps strengthening interventions in the early phase of ACL rehabilitation. Copyright © 2016 Elsevier Ltd. All rights reserved.
Biomechanical Comparison of 3 Ankle Braces With and Without Free Rotation in the Sagittal Plane
Alfuth, Martin; Klein, Dieter; Koch, Raphael; Rosenbaum, Dieter
2014-01-01
Context: Various designs of braces including hinged and nonhinged models are used to provide external support of the ankle. Hinged ankle braces supposedly allow almost free dorsiflexion and plantar flexion of the foot in the sagittal plane. It is unclear, however, whether this additional degree of freedom affects the stabilizing effect of the brace in the other planes of motion. Objective: To investigate the dynamic and passive stabilizing effects of 3 ankle braces, 2 hinged models that provide free plantar flexion–dorsiflexion in the sagittal plane and 1 ankle brace without a hinge. Design: Crossover study. Setting: University Movement Analysis Laboratory. Patients or Other Participants: Seventeen healthy volunteers (5 women, 12 men; age = 25.4 ± 4.8 years; height = 180.3 ± 6.5 cm; body mass = 75.5 ± 10.4 kg). Intervention(s): We dynamically induced foot inversion on a tilting platform and passively induced foot movements in 6 directions via a custom-built apparatus in 3 brace conditions and a control condition (no brace). Main Outcome Measure(s): Maximum inversion was determined dynamically using an in-shoe electrogoniometer. Passively induced maximal joint angles were measured using a torque and angle sensor. We analyzed differences among the 4 ankle-brace conditions (3 braces, 1 control) for each of the dependent variables with Friedman and post hoc tests (P < .05). Results: Each ankle brace restricted dynamic foot-inversion movements on the tilting platform as compared with the control condition, whereas only the 2 hinged ankle braces differed from each other, with greater movement restriction caused by the Ankle X model. Passive foot inversion was reduced with all ankle braces. Passive plantar flexion was greater in the hinged models as compared with the nonhinged brace. Conclusions: All ankle braces showed stabilizing effects against dynamic and passive foot inversion. Differences between the hinged braces and the nonhinged brace did not appear to be clinically relevant. PMID:25098661
Aminiaghdam, Soran; Rode, Christian; Müller, Roy; Blickhan, Reinhard
2017-02-01
Pronograde trunk orientation in small birds causes prominent intra-limb asymmetries in the leg function. As yet, it is not clear whether these asymmetries induced by the trunk reflect general constraints on the leg function regardless of the specific leg architecture or size of the species. To address this, we instructed 12 human volunteers to walk at a self-selected velocity with four postures: regular erect, or with 30 deg, 50 deg and maximal trunk flexion. In addition, we simulated the axial leg force (along the line connecting hip and centre of pressure) using two simple models: spring and damper in series, and parallel spring and damper. As trunk flexion increases, lower limb joints become more flexed during stance. Similar to birds, the associated posterior shift of the hip relative to the centre of mass leads to a shorter leg at toe-off than at touchdown, and to a flatter angle of attack and a steeper leg angle at toe-off. Furthermore, walking with maximal trunk flexion induces right-skewed vertical and horizontal ground reaction force profiles comparable to those in birds. Interestingly, the spring and damper in series model provides a superior prediction of the axial leg force across trunk-flexed gaits compared with the parallel spring and damper model; in regular erect gait, the damper does not substantially improve the reproduction of the human axial leg force. In conclusion, mimicking the pronograde locomotion of birds by bending the trunk forward in humans causes a leg function similar to that of birds despite the different morphology of the segmented legs. © 2017. Published by The Company of Biologists Ltd.
Umehara, Jun; Nakamura, Masatoshi; Fujita, Kosuke; Kusano, Ken; Nishishita, Satoru; Araki, Kojiro; Tanaka, Hiroki; Yanase, Ko; Ichihashi, Noriaki
2017-07-01
Stretching maneuvers for the pectoralis minor muscle, which involve shoulder horizontal abduction or scapular retraction, are performed in clinical and sports settings because the tightness of this muscle may contribute to scapular dyskinesis. The effectiveness of stretching maneuvers for the pectoralis minor muscle is unclear in vivo. The purpose of this study was to verify the effectiveness of stretching maneuvers for the pectoralis minor muscle in vivo using ultrasonic shear wave elastography. Eighteen healthy men participated in this study. Elongation of the pectoralis minor muscle was measured for 3 stretching maneuvers (shoulder flexion, shoulder horizontal abduction, and scapular retraction) at 3 shoulder elevation angles (30°, 90°, and 150°). The shear elastic modulus, used as the index of muscle elongation, was computed using ultrasonic shear wave elastography for the 9 aforementioned stretching maneuver-angle combinations. The shear elastic modulus was highest in horizontal abduction at 150°, followed by horizontal abduction at 90°, horizontal abduction at 30°, scapular retraction at 30°, scapular retraction at 90°, scapular retraction at 150°, flexion at 150°, flexion at 90°, and flexion at 30°. The shear elastic moduli of horizontal abduction at 90° and horizontal abduction at 150° were significantly higher than those of other stretching maneuvers. There was no significant difference between horizontal abduction at 90° and horizontal abduction at 150°. This study determined that shoulder horizontal abduction at an elevation of 90° and horizontal abduction at an elevation of 150° were the most effective stretching maneuvers for the pectoralis minor muscle in vivo. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Thomas, Abbey C; Lepley, Lindsey K; Wojtys, Edward M; McLean, Scott G; Palmieri-Smith, Riann M
2015-12-01
Laboratory-based experiment using a pretest/posttest design. To determine the effects of neuromuscular fatigue on quadriceps strength and activation and sagittal and frontal plane knee biomechanics during dynamic landing following anterior cruciate ligament reconstruction (ACLR). Impaired quadriceps central activation occurs post-ACLR, likely altering lower extremity biomechanics. Neuromuscular fatigue similarly reduces volitional muscle activation and impairs neuromuscular control. Upon return to full activity post-ACLR, individuals likely concurrently experience quadriceps central activation deficits and neuromuscular fatigue, though the effects of fatigue on muscle strength and activation and biomechanics post-ACLR are unknown. Seventeen individuals 7 to 10 months post-ACLR and 16 controls participated. Quadriceps strength and central activation ratio were recorded prefatigue and postfatigue, which was induced via sets of double-leg squats. Knee biomechanics were recorded during a dynamic landing activity prefatigue and postfatigue. Both groups demonstrated smaller knee flexion (initial contact, P = .017; peak, P = .004) and abduction (initial contact, P = .005; peak, P = .009) angles postfatigue. The ACLR group had smaller peak knee flexion angles (P<.001) prefatigue and postfatigue than controls. Knee flexion moment was smaller in those post-ACLR than controls prefatigue (P<.001), but not postfatigue (P = .103). Controls had smaller knee flexion moments postfatigue (P = .001). Knee abduction moment was smaller in both groups postfatigue (P = .003). All participants demonstrated significantly lower strength (P<.001) and activation (P = .003) postfatigue. Impaired strength, central activation, and biomechanics were present postfatigue in both groups, suggesting that neuromuscular fatigue may increase noncontact ACL injury risk. However, these changes were not exaggerated in those post-ACLR, likely because they already demonstrated a stiff-legged landing strategy prefatigue.
Oh, Keonyoung; Park, Sukyung
2017-02-28
A local minimum for running energetics has been reported for a specific bending stiffness, implying that shoe stiffness assists in running propulsion. However, the determinant of the metabolic optimum remains unknown. Highly stiff shoes significantly increase the moment arm of the ground reaction force (GRF) and reduce the leverage effect of joint torque at ground push-off. Inspired by previous findings, we hypothesized that the restriction of the natural metatarsophalangeal (MTP) flexion caused by stiffened shoes and the corresponding joint torque changes may reduce the benefit of shoe bending stiffness to running energetics. We proposed the critical stiffness, k cr , which is defined as the ratio of the MTP joint (MTPJ) torque to the maximal MTPJ flexion angle, as a possible threshold of the elastic benefit of shoe stiffness. 19 subjects participated in a running test while wearing insoles with five different bending stiffness levels. Joint angles, GRFs, and metabolic costs were measured and analyzed as functions of the shoe stiffness. No significant changes were found in the take-off velocity of the center of mass (CoM), but the horizontal ground push-offs were significantly reduced at different shoe stiffness levels, indicating that complementary changes in the lower-limb joint torques were introduced to maintain steady running. Slight increases in the ankle, knee, and hip joint angular impulses were observed at stiffness levels exceeding the critical stiffness, whereas the angular impulse at the MTPJ was significantly reduced. These results indicate that the shoe bending stiffness is beneficial to running energetics if it does not disturb the natural MTPJ flexion. Copyright © 2017 Elsevier Ltd. All rights reserved.
Podraza, Jeffery T; White, Scott C
2010-08-01
Investigating landing kinetics and neuromuscular control strategies during rapid deceleration movements is a prerequisite to understanding the non-contact mechanism of ACL injury. The purpose of this study was to quantify the effect of knee flexion angle on ground reaction forces, net knee joint moments, muscle co-contraction and lower extremity muscles during an impact-like, deceleration task. Ground reaction forces and knee joint moments were determined from video and force plate records of 10 healthy male subjects performing rapid deceleration single leg landings from a 10.5 cm height with different degrees of knee flexion at landing. Muscle co-contraction was based on muscle moments calculated from an EMG-to-moment processing model. Ground reaction forces and co-contraction indices decreased while knee extensor moments increased significantly with increased degrees of knee flexion at landing (all p<0.005). Higher ground reaction forces when landing in an extended knee position suggests they are a contributing factor in non-contact ACL injuries. Increased knee extensor moments and less co-contraction with flexed knee landings suggest that quadriceps overload may not be the primary cause of non-contact ACL injuries. The results bring into question the counterbalancing role of the hamstrings during dynamic movements. The soleus may be a valuable synergist stabilizing the tibia against anterior translation at landing. Movement strategies that lessen the propagation of reaction forces up the kinetic chain may help prevent non-contact ACL injuries. The relative interaction of all involved thigh and lower leg muscles, not just the quadriceps and hamstrings should be considered when interpreting non-contact ACL injury mechanisms. Copyright 2010 Elsevier B.V. All rights reserved.
Bates, Nathaniel A; Nesbitt, Rebecca J; Shearn, Jason T; Myer, Gregory D; Hewett, Timothy E
2016-07-01
Tibial slope angle is a nonmodifiable risk factor for anterior cruciate ligament (ACL) injury. However, the mechanical role of varying tibial slopes during athletic tasks has yet to be clinically quantified. To examine the influence of posterior tibial slope on knee joint loading during controlled, in vitro simulation of the knee joint articulations during athletic tasks. Descriptive laboratory study. A 6 degree of freedom robotic manipulator positionally maneuvered cadaveric knee joints from 12 unique specimens with varying tibial slopes (range, -7.7° to 7.7°) through drop vertical jump and sidestep cutting tasks that were derived from 3-dimensional in vivo motion recordings. Internal knee joint torques and forces were recorded throughout simulation and were linearly correlated with tibial slope. The mean (±SD) posterior tibial slope angle was 2.2° ± 4.3° in the lateral compartment and 2.3° ± 3.3° in the medial compartment. For simulated drop vertical jumps, lateral compartment tibial slope angle expressed moderate, direct correlations with peak internally generated knee adduction (r = 0.60-0.65), flexion (r = 0.64-0.66), lateral (r = 0.57-0.69), and external rotation torques (r = 0.47-0.72) as well as inverse correlations with peak abduction (r = -0.42 to -0.61) and internal rotation torques (r = -0.39 to -0.79). Only frontal plane torques were correlated during sidestep cutting simulations. For simulated drop vertical jumps, medial compartment tibial slope angle expressed moderate, direct correlations with peak internally generated knee flexion torque (r = 0.64-0.69) and lateral knee force (r = 0.55-0.74) as well as inverse correlations with peak external torque (r = -0.34 to -0.67) and medial knee force (r = -0.58 to -0.59). These moderate correlations were also present during simulated sidestep cutting. The investigation supported the theory that increased posterior tibial slope would lead to greater magnitude knee joint moments, specifically, internally generated knee adduction and flexion torques. The knee torques that positively correlated with increased tibial slope angle in this investigation are associated with heightened risk of ACL injury. Therefore, the present data indicated that a higher posterior tibial slope is correlated to increased knee loads that are associated with heightened risk of ACL injury. © 2016 The Author(s).
Kaur, Mandeep; Ribeiro, Daniel Cury; Theis, Jean-Claude; Webster, Kate E; Sole, Gisela
2016-12-01
Altered gait patterns follow ing anterior cruciate ligament reconstruction (ACLR) may be associated with long-term impairments and post-traumatic osteoarthritis. This systematic review and meta-analysis compared lower limb kinematics and kinetics of the ACL reconstructed knee with (1) the contralateral limb and (2) healthy age-matched participants during walking, stair climbing, and running. The secondary aim was to describe the differences over time following ACLR for these biomechanical variables. Database searches were conducted from inception to July 2014 and updated in August 2015 for studies exploring peak knee angles and moments following ACLR during walking, stair negotiation, and running. Risk of bias was assessed with a modified Downs and Black quality index for all included studies, and meta-analyses were performed. Forest plots were explored qualitatively for recovery of gait variables over time after surgery. A total of 40 studies were included in the review; 26 of these were rated as low risk and 14 as high risk of bias. The meta-analysis included 27 studies. Strong to moderate evidence indicated no significant difference in peak flexion angles between ACLR and control groups during walking and stair ascent. Strong evidence was found for lower peak flexion moments in participants with ACLR compared with control groups and contralateral limb during walking and stair activities. Strong to moderate evidence was found for lower peak adduction moment in ACLR participants for the injured compared with the contralateral limbs during walking and stair descent. The qualitative assessment for recovery over time indicated a pattern towards restoration of peak knee flexion angle with increasing time from post-surgery. Peak knee adduction moments were lower within the first year following surgery and higher than controls during later phases (5 years). Joint kinematics are restored, on average, 6 years following reconstruction, while knee external flexion moments remain lower than controls. Knee adduction moments are lower during early phases following reconstruction, but are higher than controls, on average, 5 years post-surgery. Findings indicate that knee function is not fully restored following reconstruction, and long-term maintenance programs may be needed.
LaPrade, Christopher M; Jansson, Kyle S; Dornan, Grant; Smith, Sean D; Wijdicks, Coen A; LaPrade, Robert F
2014-03-19
An avulsion of the posterior root attachment of the lateral meniscus or a radial tear close to the root attachment can lead to degenerative knee arthritis. Although the biomechanical effects of comparable injuries involving the medial meniscus have been studied, we are aware of no such study involving the lateral meniscus. We hypothesized that in situ pull-out suture repair of lateral meniscus root avulsions and of complete radial tears 3 and 6 mm from the root attachment would increase the contact area and decrease mean and peak tibiofemoral contact pressures, at all knee flexion angles, relative to the corresponding avulsion or tear condition. Eight human cadaveric knees underwent biomechanical testing. Eight lateral meniscus conditions (intact, footprint tear, root avulsion, root avulsion repair, radial tears at 3 and 6 mm from the posterior root, and repairs of the 3 and 6-mm tears) were tested at five different flexion angles (0°, 30°, 45°, 60°, and 90°) under a compressive 1000-N load. Avulsion of the posterior root of the lateral meniscus or an adjacent radial tear resulted in significantly decreased contact area and increased mean and peak contact pressures in the lateral compartment, relative to the intact condition, in all cases except the root avulsion condition at 0° of flexion. In situ pull-out suture repair of the root avulsion or radial tear significantly reduced mean contact pressures, relative to the corresponding avulsion or tear condition, when the results for each condition were pooled across all flexion angles. Posterior horn root avulsions and radial tears adjacent to the root attachment of the lateral meniscus significantly increased contact pressures in the lateral compartment. In situ pull-out suture repairs of these tears significantly improved lateral compartment joint contact pressures. In situ repair may be an effective treatment to improve tibiofemoral contact profiles after an avulsion of the posterior root of the lateral meniscus or a complete radial tear adjacent to the root. In situ repairs should be further investigated clinically as an alternative to partial lateral meniscectomy.
A proposal for a new definition of the axial rotation angle of the shoulder joint.
Masuda, Tadashi; Ishida, Akimasa; Cao, Lili; Morita, Sadao
2008-02-01
The Euler/Cardan angles are commonly used to define the motions of the upper arm with respect to the trunk. This definition, however, has a problem in that the angles of both the horizontal flexion/extension and the axial rotation of the shoulder joint become unstable at the gimbal-lock positions. In this paper, a new definition of the axial rotation angle was proposed. The proposed angle was stable over the entire range of the shoulder motion. With the new definition, the neutral position of the axial rotation agreed with that in the conventional anatomy. The advantage of the new definition was demonstrated by measuring actual complex motions of the shoulder with a three-dimensional motion capture system.
Transverse Stress Fracture of the Proximal Patella: A Case Report.
Atsumi, Satoru; Arai, Yuji; Kato, Ko; Nishimura, Akinobu; Nakazora, Shigeto; Nakagawa, Shuji; Ikoma, Kazuya; Fujiwara, Hiroyoshi; Sudo, Akihiro; Kubo, Toshikazu
2016-02-01
Among stress fractures associated with sports activities, patellar stress fracture is rare. Regarding patella stress fractures, so far only distal transverse or lateral longitudinal fractures have been reported, but there are no reports of transverse fractures occurring in the proximal patella. We describe an extremely rare case of transverse stress fracture of proximal patella in a 9-year-old athlete.A 9-year old boy, who participated in sports (sprints and Kendo) presented with left knee pain without any external injury. In plain radiographs, a fracture line was observed in the proximal 1/3 of the left patella, and a patella stress fracture was diagnosed. For treatment, because 7 months of conservative therapy showed no improvement, internal fixation was carried out using Acutrak screws, and bone union was thus achieved. Three months after the operation, he was able to return to his previous level of athletic sports activity.Regarding the mechanism of onset, it is believed that the causes are longitudinal traction force and patellofemoral contact pressure. On the other hand, the contact region of the patella with the femur changes with the flexion angle of the knee. In the current case, the fracture occurred at a site where the patella was in contact with the femur at a flexion angle of >90°, so it is believed that it occurred as a clinical condition from being subjected to repeated longitudinal traction force and patellofemoral contact pressure at a flexion angle of >90°, during the sports activities of sprints and Kendo. The nonunion of the transverse stress fracture of his proximal patella was successfully treated with internal fixation using Acutrak screws.
Potvin, Brigitte M; Shourijeh, Mohammad S; Smale, Kenneth B; Benoit, Daniel L
2017-09-06
Musculoskeletal modeling and simulations have vast potential in clinical and research fields, but face various challenges in representing the complexities of the human body. Soft tissue artifact from skin-mounted markers may lead to non-physiological representation of joint motions being used as inputs to models in simulations. To address this, we have developed adaptive joint constraints on five of the six degree of freedom of the knee joint based on in vivo tibiofemoral joint motions recorded during walking, hopping and cutting motions from subjects instrumented with intra-cortical pins inserted into their tibia and femur. The constraint boundaries vary as a function of knee flexion angle and were tested on four whole-body models including four to six knee degrees of freedom. A musculoskeletal model developed in OpenSim simulation software was constrained to these in vivo boundaries during level gait and inverse kinematics and dynamics were then resolved. Statistical parametric mapping indicated significant differences (p<0.05) in kinematics between bone pin constrained and unconstrained model conditions, notably in knee translations, while hip and ankle flexion/extension angles were also affected, indicating the error at the knee propagates to surrounding joints. These changes to hip, knee, and ankle kinematics led to measurable changes in hip and knee transverse plane moments, and knee frontal plane moments and forces. Since knee flexion angle can be validly represented using skin mounted markers, our tool uses this reliable measure to guide the five other degrees of freedom at the knee and provide a more valid representation of the kinematics for these degrees of freedom. Copyright © 2017 Elsevier Ltd. All rights reserved.
Transverse Stress Fracture of the Proximal Patella
Atsumi, Satoru; Arai, Yuji; Kato, Ko; Nishimura, Akinobu; Nakazora, Shigeto; Nakagawa, Shuji; Ikoma, Kazuya; Fujiwara, Hiroyoshi; Sudo, Akihiro; Kubo, Toshikazu
2016-01-01
Abstract Among stress fractures associated with sports activities, patellar stress fracture is rare. Regarding patella stress fractures, so far only distal transverse or lateral longitudinal fractures have been reported, but there are no reports of transverse fractures occurring in the proximal patella. We describe an extremely rare case of transverse stress fracture of proximal patella in a 9-year-old athlete. A 9-year old boy, who participated in sports (sprints and Kendo) presented with left knee pain without any external injury. In plain radiographs, a fracture line was observed in the proximal 1/3 of the left patella, and a patella stress fracture was diagnosed. For treatment, because 7 months of conservative therapy showed no improvement, internal fixation was carried out using Acutrak screws, and bone union was thus achieved. Three months after the operation, he was able to return to his previous level of athletic sports activity. Regarding the mechanism of onset, it is believed that the causes are longitudinal traction force and patellofemoral contact pressure. On the other hand, the contact region of the patella with the femur changes with the flexion angle of the knee. In the current case, the fracture occurred at a site where the patella was in contact with the femur at a flexion angle of >90°, so it is believed that it occurred as a clinical condition from being subjected to repeated longitudinal traction force and patellofemoral contact pressure at a flexion angle of >90°, during the sports activities of sprints and Kendo. The nonunion of the transverse stress fracture of his proximal patella was successfully treated with internal fixation using Acutrak screws. PMID:26871789
Biomechanics of Hyperflexion and Kneeling before and after Total Knee Arthroplasty
2014-01-01
The capacity to perform certain activities is frequently compromised after total knee arthroplasty (TKA) due to a functional decline resulting from decreased range of motion and a diminished ability to kneel. In this manuscript, the current biomechanical understanding of hyperflexion and kneeling before and after TKA will be discussed. Patellofemoral and tibiofemoral joint contact area, contact pressure, and kinematics were evaluated in cadaveric studies using a Tekscan pressure measuring system and Microscribe. Testing was performed on intact knees and following cruciate retaining and posterior stabilized TKA at knee flexion angles of 90°, 105°, 120°, and 135°. Three loading conditions were used to simulate squatting, double stance kneeling, and single stance kneeling. Following TKA with double stance kneeling, patellofemoral contact areas did not increase significantly at high knee flexion angle (135°). Kneeling resulted in tibial posterior translation and external rotation at all flexion angles. Moving from double to single stance kneeling tended to increase pressures in the cruciate retaining group, but decreased pressures in the posterior stabilized group. The cruciate retaining group had significantly larger contact areas than the posterior stabilized group, although no significant differences in pressures were observed comparing the two TKA designs (p < 0.05). If greater than 120° of postoperative knee range of motion can be achieved following TKA, then kneeling may be performed with less risk in the patellofemoral joint than was previously believed to be the case. However, kneeling may increase the likelihood of damage to cartilage and menisci in intact knees and after TKA increases in tibiofemoral contact area and pressures may lead to polyethyelene wear if performed on a chronic, repetitive basis. PMID:24900891
Biomechanics of hyperflexion and kneeling before and after total knee arthroplasty.
Lee, Thay Q
2014-06-01
The capacity to perform certain activities is frequently compromised after total knee arthroplasty (TKA) due to a functional decline resulting from decreased range of motion and a diminished ability to kneel. In this manuscript, the current biomechanical understanding of hyperflexion and kneeling before and after TKA will be discussed. Patellofemoral and tibiofemoral joint contact area, contact pressure, and kinematics were evaluated in cadaveric studies using a Tekscan pressure measuring system and Microscribe. Testing was performed on intact knees and following cruciate retaining and posterior stabilized TKA at knee flexion angles of 90°, 105°, 120°, and 135°. Three loading conditions were used to simulate squatting, double stance kneeling, and single stance kneeling. Following TKA with double stance kneeling, patellofemoral contact areas did not increase significantly at high knee flexion angle (135°). Kneeling resulted in tibial posterior translation and external rotation at all flexion angles. Moving from double to single stance kneeling tended to increase pressures in the cruciate retaining group, but decreased pressures in the posterior stabilized group. The cruciate retaining group had significantly larger contact areas than the posterior stabilized group, although no significant differences in pressures were observed comparing the two TKA designs (p < 0.05). If greater than 120° of postoperative knee range of motion can be achieved following TKA, then kneeling may be performed with less risk in the patellofemoral joint than was previously believed to be the case. However, kneeling may increase the likelihood of damage to cartilage and menisci in intact knees and after TKA increases in tibiofemoral contact area and pressures may lead to polyethyelene wear if performed on a chronic, repetitive basis.
Ali, Nicholas; Andersen, Michael Skipper; Rasmussen, John; Robertson, D Gordon E; Rouhi, Gholamreza
2014-01-01
The central tenet of this study was to develop, validate and apply various individualised 3D musculoskeletal models of the human body for application to single-leg landings over increasing vertical heights and horizontal distances. While contributing to an understanding of whether gender differences explain the higher rate of non-contact anterior cruciate ligament (ACL) injuries among females, this study also correlated various musculoskeletal variables significantly impacted by gender, height and/or distance and their interactions with two ACL injury-risk predictor variables; peak vertical ground reaction force (VGRF) and peak proximal tibia anterior shear force (PTASF). Kinematic, kinetic and electromyography data of three male and three female subjects were measured. Results revealed no significant gender differences in the musculoskeletal variables tested except peak VGRF (p = 0.039) and hip axial compressive force (p = 0.032). The quadriceps and the gastrocnemius muscle forces had significant correlations with peak PTASF (r = 0.85, p < 0.05 and r = - 0.88, p < 0.05, respectively). Furthermore, hamstring muscle force was significantly correlated with peak VGRF (r = - 0.90, p < 0.05). The ankle flexion angle was significantly correlated with peak PTASF (r = - 0.82, p < 0.05). Our findings indicate that compared to males, females did not exhibit significantly different muscle forces, or ankle, knee and hip flexion angles during single-leg landings that would explain the gender bias in non-contact ACL injury rate. Our results also suggest that higher quadriceps muscle force increases the risk, while higher hamstring and gastrocnemius muscle forces as well as ankle flexion angle reduce the risk of non-contact ACL injury.
Free groin flap for recurrent severe contractures of the neck in children
Ghosh, Abhishek; Jayakumar, R.
2010-01-01
Context: Severe post burns contracture in children not only leads to functional impairment but also has profound psychological impact on the child. Untreated neck contractures have been shown to inhibit mandibular growth. Skin grafting in children has a higher rate of recurrence and in these cases a thin pliable flap seems to provide a durable solution. Aim: To study the feasibility of using primarily thinned free groin flap in the treatment of recurrent neck contractures in children. Materials and Methods: Five patients, in the age group of 5–10 years, with recurrent neck contractures and operated between 2005 and 2008 were included in this study. The sternomental distance, lateral flexion angle and cervicomental angle were measured preoperatively, postoperatively and during the subsequent follow-up visits. The patients were followed up for a period between 1 and 3 years with a mean of 29 months. Results: All the flaps survived. The cervicomental angle improved significantly to 90–105°, the lateral flexion angle improved to 35–45° and the sternomental distance increased considerably. Conclusions: Recurrent post burns contracture of the neck in children causes not only functional and aesthetic impairment but also psychological problems. A free microthinned groin flap provides a very attractive solution for this problem and should be seen as an effective alternative in recurrent cases. PMID:21321662
Use of a wireless, inertial sensor-based system to objectively evaluate flexion tests in the horse.
Marshall, J F; Lund, D G; Voute, L C
2012-12-01
A wireless, inertial sensor-based system has previously been validated for evaluation of equine lameness. However, threshold values have not been determined for the assessment of responses to flexion tests. The aim of this investigation was to evaluate a sensor-based system for objective assessment of the response to flexion. Healthy adult horses (n = 17) in work were recruited prospectively. Horses were instrumented with sensors on the head (accelerometer), pelvis (accelerometer) and right forelimb (gyroscope), before trotting in a straight line (minimum 25 strides) for 2 consecutive trials. Sensors measured 1) vertical pelvic movement asymmetry (PMA) for both right and left hindlimb strides and 2) average difference in maximum and minimum pelvic height (PDMax and PDMin) between right and left hindlimb strides in millimetres. A hindlimb was randomly selected for proximal flexion (60 s), after which the horse trotted a minimum of 10 strides. Response to flexion was blindly assessed as negative or positive by an experienced observer. Changes in PMA, PDMax and PDMin between baseline and flexion examinations were calculated for each test. Statistical analysis consisted of a Pearson's product moment test and linear regression on baseline trials, Mann-Whitney rank sum test for effect of flexion and receiver operator curve (ROC) analysis of test parameters. There was a strong correlation between trials for PMA, PDMin and PDMax measurements (P < 0.001). A positive flexion test resulted in a significant increase in PMA (P = 0.021) and PDMax (P = 0.05) only. Receiver-operator curve analysis established cut-off values for change in PMA and PDMax of 0.068 and 4.47 mm, respectively (sensitivity = 0.71, specificity = 0.65) to indicate a positive response to flexion. A positive response to flexion resulted in significant changes to objective measurements of pelvic symmetry. Findings support the use of inertial sensor systems to objectively assess response to flexion tests. Further investigation is warranted to establish cut-off values for objective assessment of other diagnostic procedures.
Neblett, Randy; Mayer, Tom G; Brede, Emily; Gatchel, Robert J
2014-06-01
Abnormal pretreatment flexion-relaxation in chronic disabling occupational lumbar spinal disorder patients has been shown to improve with functional restoration rehabilitation. Little is known about the effects of prior lumbar surgeries on flexion-relaxation and its responsiveness to treatment. To quantify the effect of prior lumbar surgeries on the flexion-relaxation phenomenon and its responsiveness to rehabilitative treatment. A prospective cohort study of chronic disabling occupational lumbar spinal disorder patients, including those with and without prior lumbar spinal surgeries. A sample of 126 chronic disabling occupational lumbar spinal disorder patients with prior work-related injuries entered an interdisciplinary functional restoration program and agreed to enroll in this study. Fifty-seven patients had undergone surgical decompression or discectomy (n=32) or lumbar fusion (n=25), and the rest had no history of prior injury-related spine surgery (n=69). At post-treatment, 116 patients were reevaluated, including those with prior decompressions or discectomies (n=30), lumbar fusions (n=21), and no surgery (n=65). A comparison group of 30 pain-free control subjects was tested with an identical assessment protocol, and compared with post-rehabilitation outcomes. Mean surface electromyography (SEMG) at maximum voluntary flexion; subject achievement of flexion-relaxation (SEMG≤3.5 μV); gross lumbar, true lumbar, and pelvic flexion ROM; and a pain visual analog scale self-report during forward bending task. Identical measures were obtained at pretreatment and post-treatment. Patients entered an interdisciplinary functional restoration program, including a quantitatively directed, medically supervised exercise process and a multimodal psychosocial disability management component. The functional restoration program was accompanied by a SEMG-assisted stretching training program, designed to teach relaxation of the lumbar musculature during end-range flexion, thereby improving or normalizing flexion-relaxation and increasing lumbar flexion ROM. At 1 year after discharge from the program, a structured interview was used to obtain socioeconomic outcomes. At pre-rehabilitation, the no surgery group patients demonstrated significantly better performance than both surgery groups on absolute SEMG at maximum voluntary flexion and on true lumbar flexion ROM. Both surgery groups were less likely to achieve flexion-relaxation than the no surgery patients. The fusion patients had reduced gross lumbar flexion ROM and greater pain during bending compared with the no surgery patients, and reduced true lumbar flexion ROM compared with the discectomy patients. At post-rehabilitation, all groups improved substantially on all measures. When post-rehabilitation measures were compared with the pain-free control group, with gross and true lumbar ROM corrected by 8° per spinal segment fused, there were no differences between any of the patient groups and the pain-free control subjects on spinal ROM and only small differences in SEMG. The three groups had comparable socioeconomic outcomes at 1 year post-treatment in work retention, health-care utilization, new injury, and new surgery. Despite the fact that the patients with prior surgery demonstrated greater pretreatment SEMG and ROM deficits, functional restoration treatment, combined with SEMG-assisted stretching training, was successful in improving all these measures by post-treatment. After treatment, both groups demonstrated ROM within anticipated limits, and the majority of patients in all three groups successfully achieved flexion-relaxation. In a chronic disabling occupational lumbar spinal disorder cohort, surgery patients were nearly equal to nonoperated patients in responding to interdisciplinary functional restoration rehabilitation on measures investigated in this study, achieving close to normal performance measures associated with pain-free controls. The responsiveness and final scores shown in this study suggests that flexion-relaxation may be a useful, objective diagnostic tool to measure changes in physical capacity for chronic disabling occupational lumbar spinal disorder patients. Copyright © 2014 Elsevier Inc. All rights reserved.
Witoolkollachit, Polawat; Seubchompoo, Onuma
2008-07-01
The tibial axis referencing method with a balanced tension flexion gap at 90 degrees knee flexion provides adequate femoral component rotation usually in external rotation, the trans-epicondylar line being parallel to the proximal tibial cut. The LCS mobile bearing TKA uses this technique to automatically determine the femoral component rotation with desired tension. The determination of the epicondyles may lead to some confusion. On the lateral side, the prominence of the lateral condyle makes it easy to define. However on the medial side, some surgeons use the prominent part of the medial epicondyle (well recognized on CT scan as the most proximal ridge that gives insertion to the superficial collateral ligament) and use the anatomical transepicondylar axis (aTEA). Other surgeons use the depression below called sulcus that defines the surgical transepicondylar axis (sTEA). The authors evaluated 40 clinically successful mobile bearing TKA in 33 patients. All the knees were performed by single surgeon and the rotational alignment of the femoral component was applied with balanced flexion gap technique. Post-op CT-scans were done in all knees with 2-mm interval and measurement of the different angles (between aTEA and the prosthetic posterior condylar line and between the sTEA and the prosthetic posterior condylar line) with the UTHSCSA Imagetool (IT) version 3 from the University of Texas Health Science Center at San Antonio. The authors found that the mean femoral implant angle was in 2.39 degrees (SD = 2.80) of internal rotation with reference to the aTEA and in 1.34 degrees (SD = 1.57 degrees) of external rotation with reference to the sTEA when the medial sulcus was perfectly detected (nine knees, 22.5%). The angle between the aTEA and the sTEA was -3.98 degrees (SD = 1.05 degrees). No patella subluxation was identified. Nineteen or 47.5% of the femoral components were in internal or external femoral rotation of more than 3 degrees to the aTEA. When sTEA was detected, no knee was in internal or external rotation more than 3 degrees to sTEA. The balanced flexion gap technique positions the femoral component in external rotation with the LCS TKA. Within 3 degrees to aTEA or sTEA, this technique produced femoral rotational angle closer to sTEA when the sulcus was detected and produced a wide range of different angles when compared to aTEA. However sTEA is not the consistent bony landmark. This technique is a reliable method to determine femoral rotational alignment.
Stress analysis in patella by three-dimensional photoelasticity
NASA Astrophysics Data System (ADS)
Chen, Riqi; Zhang, Jianxing; Jiang, Kunsheng
1991-12-01
In this paper, stress distribution in patella was studied by 3-D photoelastic experiments and finite element calculations. The experimental conditions were in good agreement with that of body mechanics: (1) The ratios of m. quadriceps femoris force FQ to lig. patella force FP were 1.03 - 1.42. (2) The angles between FQ and FP were 8.4 degree(s) - 18.7 degree(s). (3) The ratio of modulus of elasticity for epoxy resin and silicon rubber matched that for patella and cartilage, i.e., 145:1. The principal stresses and their path line, normal stresses, and contact stresses between patella and ossis femoris were determined in various flexion angles (15 degree(s), 30 degree(s), 45 degree(s), 60 degree(s), 75 degree(s), 90 degree(s)). Two of the correlations were: (1) Maximum principal stress in the front of patella; (sigma) max equals 35.8Wexp(0.024(alpha) ) KPa. (2) Maximum contact stress between patella and ossis femoris; (sigma) max equals -(6.86 - 0.14(alpha) + 0.02(alpha) 2)W KPa where W was body weight subjected by a single foot. It was proved that the transverse break of patella resulted from the case that the principle stress in the front of patella exceeded ultimate tensile strength. And Tension Band Wiring (TBW) therapy conformed to the law of physiological stress field. A modified K-needles position in TBW therapy was suggested. These results are useful for further research of human patella mechanics and recovery therapy. No similar result has been found in American MEDLIN Data Bank.
Strain measurements of the tibial insert of a knee prosthesis using a knee motion simulator.
Sera, Toshihiro; Iwai, Yuya; Yamazaki, Takaharu; Tomita, Tetsuya; Yoshikawa, Hideki; Naito, Hisahi; Matsumoto, Takeshi; Tanaka, Masao
2017-12-01
The longevity of a knee prosthesis is influenced by the wear of the tibial insert due to its posture and movement. In this study, we assumed that the strain on the tibial insert is one of the main reasons for its wear and investigated the influence of the knee varus-valgus angles on the mechanical stress of the tibial insert. Knee prosthesis motion was simulated using a knee motion simulator based on a parallel-link six degrees-of-freedom actuator and the principal strain and pressure distribution of the tibial insert were measured. In particular, the early stance phase obtained from in vivo X-ray images was examined because the knee is applied to the largest load during extension/flexion movement. The knee varus-valgus angles were 0° (neutral alignment), 3°, and 5° malalignment. Under a neutral orientation, the pressure was higher at the middle and posterior condyles. The first and second principal strains were larger at the high and low pressure areas, respectively. Even for a 3° malalignment, the load was concentrated at one condyle and the positive first principal strain increased dramatically at the high pressure area. The negative second principal strain was large at the low pressure area on the other condyle. The maximum equivalent strain was 1.3-2.1 times larger at the high pressure area. For a 5° malalignment, the maximum equivalent strain increased slightly. These strain and pressure measurements can provide the mechanical stress of the tibial insert in detail for determining the longevity of an artificial knee joint.
Clinical measurement of the dart throwing motion of the wrist: variability, accuracy and correction.
Vardakastani, Vasiliki; Bell, Hannah; Mee, Sarah; Brigstocke, Gavin; Kedgley, Angela E
2018-01-01
Despite being functionally important, the dart throwing motion is difficult to assess accurately through goniometry. The objectives of this study were to describe a method for reliably quantifying the dart throwing motion using goniometric measurements within a healthy population. Wrist kinematics of 24 healthy participants were assessed using goniometry and optical motion tracking. Three wrist angles were measured at the starting and ending points of the motion: flexion-extension, radial-ulnar deviation and dart throwing motion angle. The orientation of the dart throwing motion plane relative to the flexion-extension axis ranged between 28° and 57° among the tested population. Plane orientations derived from optical motion capture differed from those calculated through goniometry by 25°. An equation to correct the estimation of the plane from goniometry measurements was derived. This was applied and differences in the orientation of the plane were reduced to non-significant levels, enabling the dart throwing motion to be measured using goniometry alone.
Fujimaki, Yoshimasa; Thorhauer, Eric; Sasaki, Yusuke; Smolinski, Patrick; Tashman, Scott; Fu, Freddie H
2016-01-01
Quantification of the cross-sectional area (CSA) of the anterior cruciate ligament (ACL) in different loading conditions is important for understanding the native anatomy and thus achieving anatomic reconstruction. The ACL insertion sites are larger than the ACL midsubstance, and the isthmus (region of the smallest CSA) location may vary with the load or flexion angle. To (1) quantify the CSA along the entire ACL, (2) describe the location of the ACL isthmus, (3) explore the relationship between ACL length and CSA, and (4) validate magnetic resonance imaging (MRI) for assessing the CSA of the midsubstance ACL. Descriptive laboratory study. Eight cadaveric knees were dissected to expose the ACL and its attachments. Knees were positioned using a robotic loading system through a range of flexion angles in 3 loading states: (1) unloaded, (2) anterior tibial translation, and (3) combined rotational load of valgus and internal torque. Laser scanning quantified the shape of the ACL and its insertion site boundaries. The CSA of the ACL was measured, and the location of the isthmus was determined; the CSA of the ACL was also estimated from MRI and compared with the laser-scanned data. The CSA of the ACL varied along the ligament, and the isthmus existed at an average (±SD) of 53.8% ± 5.5% of the distance from the tibial insertion center to the femoral insertion center. The average CSA at the isthmus was smallest in extension (39.9 ± 13.7 mm(2)) and increased with flexion (43.9 ± 12.1 mm(2) at 90°). The ACL length was shortest at 90° of flexion and increased by 18.8% ± 10.1% in unloaded extension. Application of an anterior load increased the ACL length by 5.0% ± 3.3% in extension, and application of a combined rotational load increased its length by 4.1% ± 3.0% in extension. The ACL isthmus is located almost half of the distance between the insertion sites. The CSA of the ACL at the isthmus is largest with the knee unloaded and at 90° of flexion, and the area decreases with extension and applied loads. The CSA at the isthmus represents less than half the area of the insertion sites. These results may aid surgical planning, specifically for choosing a graft size and fixation angle that most closely matches the native anatomy and function across the entire range of knee motion. © 2015 The Author(s).
Effects of muscle activation on shear between human soleus and gastrocnemius muscles.
Finni, T; Cronin, N J; Mayfield, D; Lichtwark, G A; Cresswell, A G
2017-01-01
Lateral connections between muscles provide pathways for myofascial force transmission. To elucidate whether these pathways have functional roles in vivo, we examined whether activation could alter the shear between the soleus (SOL) and lateral gastrocnemius (LG) muscles. We hypothesized that selective activation of LG would decrease the stretch-induced shear between LG and SOL. Eleven volunteers underwent a series of knee joint manipulations where plantar flexion force, LG, and SOL muscle fascicle lengths and relative displacement of aponeuroses between the muscles were obtained. Data during a passive full range of motion were recorded, followed by 20° knee extension stretches in both passive conditions and with selective electrical stimulation of LG. During active stretch, plantar flexion force was 22% greater (P < 0.05) and relative displacement of aponeuroses was smaller than during passive stretch (P < 0.05). Soleus fascicle length changes did not differ between passive and active stretches but LG fascicles stretched less in the active than passive condition when the stretch began at angles of 70° and 90° of knee flexion (P < 0.05). The activity-induced decrease in the relative displacement of SOL and LG suggests stronger (stiffer) connectivity between the two muscles, at least at flexed knee joint angles, which may serve to facilitate myofascial force transmission. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Does high knee flexion cause separation of meniscal repairs?
Lin, David L; Ruh, Sarah S; Jones, Hugh L; Karim, Azim; Noble, Philip C; McCulloch, Patrick C
2013-09-01
Previous clinical studies comparing nonrestrictive and restrictive protocols after meniscal repair have shown no difference in outcomes; however, some surgeons still limit range of motion out of concern that it will place undue stress on the repair. Large acute medial meniscal tears will gap during simulated open chain exercises at high flexion angles, and a repaired construct with vertical mattress sutures will not gap. Controlled laboratory study. Tantalum beads were implanted in the medial menisci of 6 fresh-frozen cadaveric knees via an open posteromedial approach. Each knee underwent 10 simulated open chain flexion cycles with loading of the quadriceps and hamstrings. Testing was performed on 3 different states of the meniscus: intact, torn, and repaired. Biplanar radiographs were taken of the loaded knee in 90°, 110°, and 135° of flexion for each state. A 2.5-cm tear was created in the posteromedial meniscus and repaired with inside-out vertical mattress sutures. Displacement of pairs of beads spanning the tear was measured in all planes by use of radiostereometric analysis (RSA) with an accuracy of better than 80 μm. With a longitudinal tear, compression rather than gapping occurred in all 3 regions of the posterior horn of the meniscus (mean ± standard deviation for medial collateral ligament [MCL], -321 ± 320 μm; midposterior, -487 ± 256 μm; root, -318 ± 150 μm) with knee flexion. After repair, meniscal displacement returned part way to intact values in both the MCL (+55 ± 250 μm) and root region (-170 ± 123 μm) but not the midposterior region, where further compression was seen (-661 ± 278 μm). Acute posteromedial meniscal tears and repairs with vertical mattress sutures do not gap, but rather compress in the transverse plane at higher flexion angles when subjected to physiologic loads consistent with active, open kinetic chain range of motion rehabilitation exercises. The kinematics of the repaired meniscus more closely resemble that of the intact meniscus than that of the torn meniscus in regions adjacent to the MCL and the root but not in the midposterior region, where meniscal repair led to increased compression across the tear plane. This study supports the idea that nonrestrictive unresisted open chain range of motion protocols do not place undue stress on meniscal repairs.
Cohen, Steven B; Woods, Daniel P; Siegler, Sorin; Dodson, Christopher C; Namani, Ramya; Ciccotti, Michael G
2015-02-01
Ulnar collateral ligament (UCL) injuries have been successfully treated by the docking reconstruction. Although fixation of the graft has been suggested at 30° of elbow flexion, no quantitative biomechanical data exist to provide guidelines for the optimal elbow flexion angle for graft fixation. Testing was conducted on 10 matched pairs of cadaver elbows with use of a loading system and optoelectric tracking device. After biomechanical data on the native UCL were obtained, reconstruction by the docking technique was performed with use of palmaris longus autograft with one elbow fixated at 30° and the contralateral elbow at 90° of elbow flexion. Biomechanical testing was undertaken on these specimens. The load to failure of the native UCL (mean, 20.1 N-m) was significantly higher (P = .004) than that of the reconstructed UCL (mean, 4.6 N-m). There was no statistically significant difference in load to failure of the UCL reconstructions fixated at 30° of elbow flexion (average, 4.86 N-m) compared with those at 90° (average, 4.35 N-m). Elbows reconstructed at 30° and 90° of elbow flexion produced similar kinematic coupling and valgus laxity characteristics compared with each other and with the intact UCL. Although not statistically significant, the reconstructions fixated at 30° more closely resembled the biomechanical characteristics of the intact elbow than did reconstructions fixated at 90°. No statistically significant difference was found in comparing the docking technique of UCL reconstruction with graft fixation at 30° vs. 90° of elbow flexion. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Sheppard, P S; Stevenson, J M; Graham, R B
2016-05-01
The objective of the present study was to determine if there is a sex-based difference in lifting technique across increasing-load conditions. Eleven male and 14 female participants (n = 25) with no previous history of low back disorder participated in the study. Participants completed freestyle, symmetric lifts of a box with handles from the floor to a table positioned at 50% of their height for five trials under three load conditions (10%, 20%, and 30% of their individual maximum isometric back strength). Joint kinematic data for the ankle, knee, hip, and lumbar and thoracic spine were collected using a two-camera Optotrak motion capture system. Joint angles were calculated using a three-dimensional Euler rotation sequence. Principal component analysis (PCA) and single component reconstruction were applied to assess differences in lifting technique across the entire waveforms. Thirty-two PCs were retained from the five joints and three axes in accordance with the 90% trace criterion. Repeated-measures ANOVA with a mixed design revealed no significant effect of sex for any of the PCs. This is contrary to previous research that used discrete points on the lifting curve to analyze sex-based differences, but agrees with more recent research using more complex analysis techniques. There was a significant effect of load on lifting technique for five PCs of the lower limb (PC1 of ankle flexion, knee flexion, and knee adduction, as well as PC2 and PC3 of hip flexion) (p < 0.005). However, there was no significant effect of load on the thoracic and lumbar spine. It was concluded that when load is standardized to individual back strength characteristics, males and females adopted a similar lifting technique. In addition, as load increased male and female participants changed their lifting technique in a similar manner. Copyright © 2016. Published by Elsevier Ltd.
Conservative management of pes valgus with plantar flexed talus, flexible.
Bleck, E E; Berzins, U J
1977-01-01
The type of flat foot that we have called pes valgus with plantar flexed talus, flexible, was treated in children with the Helfet heel seat or the UCBL shoe insert. In follow-up examination of 71 cases for periods longer than one year, 79 per cent of the patients showed that the UCBL shoe insert and the Helfet heel seat improved the clinical and roentgenographic appearance of the foot. The Helfet heel seat is recommended in cases where the plantar flexion angle of the talus is 35 to 45 degrees and the UCBL shoe insert in those cases of plantar flexion of the talus greater than 45 degrees.
Teeter, Matthew G; Perry, Kevin I; Yuan, Xunhua; Howard, James L; Lanting, Brent A
2018-03-01
Contact kinematics between total knee arthroplasty components is thought to affect implant migration; however, the interaction between kinematics and tibial component migration has not been thoroughly examined in a modern implant system. A total of 24 knees from 23 patients undergoing total knee arthroplasty with a single radius, posterior stabilized implant were examined. Patients underwent radiostereometric analysis at 2 and 6 weeks, 3 and 6 months, and 1 and 2 years to measure migration of the tibial component in all planes. At 1 year, patients also had standing radiostereometric analysis examinations acquired in 0°, 20°, 40°, and 60° of flexion, and the location of contact and magnitude of any condylar liftoff was measured for each flexion angle. Regression analysis was performed between kinematic variables and migration at 1 year. The average magnitude of maximum total point motion across all patients was 0.671 ± 0.270 mm at 1 year and 0.608 ± 0.359 mm at 2 years (P = .327). Four implants demonstrated continuous migration of >0.2 mm between the first and second year of implantation. There were correlations between the location of contact and tibial component anterior-posterior tilt, varus-valgus tilt, and anterior-posterior translation. The patients with continuous migration demonstrated atypical kinematics and condylar liftoff in some instances. Kinematics can influence tibial component migration, likely through alterations of force transmission. Abnormal kinematics may play a role in long-term implant loosening. Copyright © 2017 Elsevier Inc. All rights reserved.
Akazawa, Naoki; Okawa, Naomi; Kishi, Masaki; Nakatani, Kiyoshi; Nishikawa, Katsuya; Tokumura, Daichi; Matsui, Yuji; Moriyama, Hideki
2016-09-01
The purpose of this study was to examine the effect of long-term self-massage at the musculotendinous junction on hamstring extensibility, stiffness, stretch tolerance, and structural indices. Single-blind, randomized, controlled trial. Laboratory. Thirty-seven healthy men. The right or left leg of each participant was randomly assigned to the massage group, and the other leg was assigned to the control group. The participants conducted self-massage at the musculotendinous junction for 3 min daily, five times per week, for 12 weeks. Hamstring extensibility, stiffness, stretch tolerance, and structural indices were measured by a blinded examiner prior to the massage intervention and after 6 and 12 weeks of intervention. The maximum hip flexion angle (HFA) and the maximum passive pressure after 6 and 12 weeks of intervention in the massage group were significantly higher than prior to intervention. The visual analog scale (for pain perception) at maximum HFA, the stiffness of the hamstring, and the structural indices did not differ in either group over the 12 week period. Our results suggest that long-term self-massage at the musculotendinous junction increases hamstring extensibility by improving stretch tolerance. However, this intervention does not change hamstring stiffness. University Hospital Medical Information Network registration number UMIN000011233. Copyright © 2016 Elsevier Ltd. All rights reserved.
Shim, Jae Kun; Karol, Sohit; Hsu, Jeffrey; de Oliveira, Marcio Alves
2008-04-01
The aim of this study was to investigate the contralateral motor overflow in children during single-finger and multi-finger maximum force production tasks. Forty-five right handed children, 5-11 years of age produced maximum isometric pressing force in flexion or extension with single fingers or all four fingers of their right hand. The forces produced by individual fingers of the right and left hands were recorded and analyzed in four-dimensional finger force vector space. The results showed that increases in task (right) hand finger forces were linearly associated with non-task (left) hand finger forces. The ratio of the non-task hand finger force magnitude to the corresponding task hand finger force magnitude, termed motor overflow magnitude (MOM), was greater in extension than flexion. The index finger flexion task showed the smallest MOM values. The similarity between the directions of task hand and non-task hand finger force vectors in four-dimensional finger force vector space, termed motor overflow direction (MOD), was the greatest for index and smallest for little finger tasks. MOM of a four-finger task was greater than the sum of MOMs of single-finger tasks, and this phenomenon was termed motor overflow surplus. Contrary to previous studies, no single-finger or four-finger tasks showed significant changes of MOM or MOD with the age of children. We conclude that the contralateral motor overflow in children during finger maximum force production tasks is dependent upon the task fingers and the magnitude and direction of task finger forces.
Matsuda, Mayumi; Mataki, Yuki; Mutsuzaki, Hirotaka; Yoshikawa, Kenichi; Takahashi, Kazushi; Enomoto, Keiko; Sano, Kumiko; Mizukami, Masafumi; Tomita, Kazuhide; Ohguro, Haruka; Iwasaki, Nobuaki
2018-01-01
[Purpose] Robot-assisted gait training (RAGT) using Hybrid Assistive Limb (HAL, CYBERDYNE) was previously reported beneficial for stroke and spinal cord injury patients. Here, we investigate the immediate effect of a single session of RAGT using HAL on gait function for cerebral palsy (CP) patients. [Subjects and Methods] Twelve patients (average age: 16.2 ± 7.3 years) with CP received a single session of RAGT using HAL. Gait speed, step length, cadence, single-leg support per gait cycle, hip and knee joint angle in stance, and swing phase per gait cycle were assessed before, during, and immediately after HAL intervention. [Results] Compared to baseline values, single-leg support per gait cycle (64.5 ± 15.8% to 69.3 ± 12.1%), hip extension angle in mid-stance (149.2 ± 19.0° to 155.5 ± 20.1°), and knee extension angle in mid-stance (137.6 ± 20.2° to 143.1 ± 19.5°) were significantly increased immediately after intervention. Further, the knee flexion angle in mid-swing was significantly decreased immediately after treatment (112.0 ± 15.5° to 105.2 ± 17.1°). Hip flexion angle in mid-swing also decreased following intervention (137.2 ± 14.6° to 129.7 ± 16.6°), but not significantly. Conversely, gait speed, step length, and cadence were unchanged after intervention. [Conclusion] A single-time RAGT with HAL improved single-leg support per gait cycle and hip and knee joint angle during gait, therapeutically improving gait function in CP patients. PMID:29545679
Kinematic analysis of upper extremity movement during drinking in hemiplegic subjects.
Kim, Kyung; Song, Won-Kyung; Lee, Jeongsu; Lee, Hwi-Young; Park, Dae Sung; Ko, Byung-Woo; Kim, Jongbae
2014-03-01
It is necessary to analyze the kinematic properties of a paralyzed extremity to quantitatively determine the degree of impairment of hemiplegic people during functional activities of daily living (ADL) such as a drinking task. This study aimed to identify the kinematic differences between 16 hemiplegic and 32 able-bodied participants in relation to the task phases when drinking with a cup and the kinematic strategy used during motion with respect to the gravity direction. The subjects performed a drinking task that was divided into five phases according to Murphy's phase definition: reaching, forward transport, drinking, backward transport, and returning. We found that the groups differed in terms of the movement times and the joint angles and angular velocities of the shoulder, elbow, and wrist joints. Compared to the control group, the hemiplegic participants had a larger shoulder abduction angle of at most 17.1° during all the phases, a larger shoulder flexion angle of 7.6° during the reaching phase, and a smaller shoulder flexion angle of 6.4° during the backward transporting phase. Because of these shoulder joint patterns, a smaller elbow pronation peak angle of at most 13.1° and a larger wrist extension peak angle of 12.0° were found in the motions of the hemiplegic participants, as compensation to complete the drinking task. The movement in the gravity direction during the backward transporting phase resulted in a 15.9% larger peak angular velocity for elbow extension in the hemiplegic participants compared to that of the control group. These quantitative kinematic patterns help provide an understanding of the movements of an affected extremity and can be useful in designing rehabilitation robots to assist hemiplegic people with ADL. Copyright © 2013 Elsevier Ltd. All rights reserved.
Anderson, Dennis E; Madigan, Michael L
2014-03-21
Limited plantar flexor strength and hip extension range of motion (ROM) in older adults are believed to underlie common age-related differences in gait. However, no studies of age-related differences in gait have quantified the percentage of strength and ROM used during gait. We examined peak hip angles, hip torques and plantar flexor torques, and corresponding estimates of functional capacity utilized (FCU), which we define as the percentage of available strength or joint ROM used, in 10 young and 10 older healthy adults walking under self-selected and controlled (slow and fast) conditions. Older adults walked with about 30% smaller hip extension angle, 28% larger hip flexion angle, 34% more hip extensor torque in the slow condition, and 12% less plantar flexor torque in the fast condition than young adults. Older adults had higher FCU than young adults for hip flexion angle (47% vs. 34%) and hip extensor torque (48% vs. 27%). FCUs for plantar flexor torque (both age groups) and hip extension angle (older adults in all conditions; young adults in self-selected gait) were not significantly <100%, and were higher than for other measures examined. Older adults lacked sufficient hip extension ROM to walk with a hip extension angle as large as that of young adults. Similarly, in the fast gait condition older adults lacked the strength to match the plantar flexor torque produced by young adults. This supports the hypothesis that hip extension ROM and plantar flexor strength are limiting factors in gait and contribute to age-related differences in gait. Copyright © 2014 Elsevier Ltd. All rights reserved.
Matsuda, Mayumi; Mataki, Yuki; Mutsuzaki, Hirotaka; Yoshikawa, Kenichi; Takahashi, Kazushi; Enomoto, Keiko; Sano, Kumiko; Mizukami, Masafumi; Tomita, Kazuhide; Ohguro, Haruka; Iwasaki, Nobuaki
2018-02-01
[Purpose] Robot-assisted gait training (RAGT) using Hybrid Assistive Limb (HAL, CYBERDYNE) was previously reported beneficial for stroke and spinal cord injury patients. Here, we investigate the immediate effect of a single session of RAGT using HAL on gait function for cerebral palsy (CP) patients. [Subjects and Methods] Twelve patients (average age: 16.2 ± 7.3 years) with CP received a single session of RAGT using HAL. Gait speed, step length, cadence, single-leg support per gait cycle, hip and knee joint angle in stance, and swing phase per gait cycle were assessed before, during, and immediately after HAL intervention. [Results] Compared to baseline values, single-leg support per gait cycle (64.5 ± 15.8% to 69.3 ± 12.1%), hip extension angle in mid-stance (149.2 ± 19.0° to 155.5 ± 20.1°), and knee extension angle in mid-stance (137.6 ± 20.2° to 143.1 ± 19.5°) were significantly increased immediately after intervention. Further, the knee flexion angle in mid-swing was significantly decreased immediately after treatment (112.0 ± 15.5° to 105.2 ± 17.1°). Hip flexion angle in mid-swing also decreased following intervention (137.2 ± 14.6° to 129.7 ± 16.6°), but not significantly. Conversely, gait speed, step length, and cadence were unchanged after intervention. [Conclusion] A single-time RAGT with HAL improved single-leg support per gait cycle and hip and knee joint angle during gait, therapeutically improving gait function in CP patients.
Boone, David A; Kobayashi, Toshiki; Chou, Teri G; Arabian, Adam K; Coleman, Kim L; Orendurff, Michael S; Zhang, Ming
2013-04-01
Alignment - the process and measured orientation of the prosthetic socket relative to the foot - is important for proper function of a transtibial prosthesis. Prosthetic alignment is performed by prosthetists using visual gait observation and amputees' feedback. The aim of this study was to investigate the effect of transtibial prosthesis malalignment on the moments measured at the base of the socket: the socket reaction moments. Eleven subjects with transtibial amputation were recruited from the community. An instrumented prosthesis alignment component was used to measure socket reaction moments during ambulation under 17 alignment conditions, including nominally aligned using conventional clinical methods, and angle perturbations of 3° and 6° (flexion, extension, abduction, and adduction) and translation perturbations of 5mm and 10mm (anterior, posterior, lateral, and medial) referenced from the nominal alignment. Coronal alignment perturbations caused systematic changes in the coronal socket reaction moments. All angle and translation perturbations revealed statistically significant differences on coronal socket reaction moments compared to the nominal alignment at 30% and 75% of stance phase (P<0.05). The effect of sagittal alignment perturbations on sagittal socket reaction moments was not as responsive as that of the coronal perturbations. The sagittal angle and translation perturbations of the socket led to statistically significant changes in minimum moment, maximum moment, and moments at 45% of stance phase in the sagittal plane. Therefore, malalignment affected the socket reaction moments in amputees with transtibial prostheses. Copyright © 2012 Elsevier B.V. All rights reserved.
Real-time controller for foot-drop correction by using surface electromyography sensor.
Al Mashhadany, Yousif I; Abd Rahim, Nasrudin
2013-04-01
Foot drop is a disease caused mainly by muscle paralysis, which incapacitates the nerves generating the impulses that control feet in a heel strike. The incapacity may stem from lesions that affect the brain, the spinal cord, or peripheral nerves. The foot becomes dorsiflexed, affecting normal walking. A design and analysis of a controller for such legs is the subject of this article. Surface electromyography electrodes are connected to the skin surface of the human muscle and work on the mechanics of human muscle contraction. The design uses real surface electromyography signals for estimation of the joint angles. Various-speed flexions and extensions of the leg were analyzed. The two phases of the design began with surface electromyography of real human leg electromyography signal, which was subsequently filtered, amplified, and normalized to the maximum amplitude. Parameters extracted from the surface electromyography signal were then used to train an artificial neural network for prediction of the joint angle. The artificial neural network design included various-speed identification of the electromyography signal and estimation of the angles of the knee and ankle joints by a recognition process that depended on the parameters of the real surface electromyography signal measured through real movements. The second phase used artificial neural network estimation of the control signal, for calculation of the electromyography signal to be stimulated for the leg muscle to move the ankle joint. Satisfactory simulation (MATLAB/Simulink version 2012a) and implementation results verified the design feasibility.
Catelli, Danilo S; Kowalski, Erik; Beaulé, Paul E; Lamontagne, Mario
2017-10-01
Total hip arthroplasty (THA) using dual-mobility (DM) design permits larger hip range of motion. However, it is unclear how it benefits the patients during activities of daily living. The purpose was to compare kinematic variables of the operated limb between THA patients using either DM or single-bearing (SB) implants during a squat task. Twenty-four THA patients were randomly assigned to either a DM or SB implant and matched to 12 healthy controls (CTRLs). They underwent 3-dimensional squat motion analysis before and 9 months after surgery. Sagittal and frontal plane angles of the pelvis and the hip were analyzed using statistical parametric mapping. Paired analyses compared presurgery and postsurgery squat depth. Peak sagittal pelvis angle of DM was closer to normal compared with that of SB. Both implant groups had similar hip angle patterns and magnitude but significantly lower than the CTRLs. SB reached a much large hip abduction compared with the other groups. Both surgical groups had significantly worst squat depth than the CTRLs. Neither THA implant groups were able to return pelvis and hip kinematics to the level of CTRLs. The deficit of DM implants at the pelvis combined with the poorer functional scores should caution clinicians to use this implant design in active patients. SB design causes a larger hip abduction to reach their maximum squat depth. Post-THA rehabilitation should focus on improving joint range of motion and strength. Copyright © 2017 Elsevier Inc. All rights reserved.
2009-09-24
flexion angle, decreased vertical ground-reaction force , and increased hip internal rotation angle during the jump -landing task. Additionally, decreased...was to determine the biomechanical risk factors for PFPS. The specific factors examined were lower extremity kinematics and kinetics during a jump ...ACL Injury [ JUMP -ACL] study) in which baseline data are collected for participants at all 3 service academies (USNA, United States Air Force Academy
Accuracy of visual estimates of joint angle and angular velocity using criterion movements.
Morrison, Craig S; Knudson, Duane; Clayburn, Colby; Haywood, Philip
2005-06-01
A descriptive study to document undergraduate physical education majors' (22.8 +/- 2.4 yr. old) estimates of sagittal plane elbow angle and angular velocity of elbow flexion visually was performed. 42 subjects rated videotape replays of 30 movements organized into three speeds of movement and two criterion elbow angles. Video images of the movements were analyzed with Peak Motus to measure actual values of elbow angles and peak angular velocity. Of the subjects 85.7% had speed ratings significantly correlated with true peak elbow angular velocity in all three angular velocity conditions. Few (16.7%) subjects' ratings of elbow angle correlated significantly with actual angles. Analysis of the subjects with good ratings showed the accuracy of visual ratings was significantly related to speed, with decreasing accuracy for slower speeds of movement. The use of criterion movements did not improve the small percentage of novice observers who could accurately estimate body angles during movement.
Khadilkar, Leenesh; MacDermid, Joy C; Sinden, Kathryn E; Jenkyn, Thomas R; Birmingham, Trevor B; Athwal, George S
2014-01-01
Video-based movement analysis software (Dartfish) has potential for clinical applications for understanding shoulder motion if functional measures can be reliably obtained. The primary purpose of this study was to describe the functional range of motion (ROM) of the shoulder used to perform a subset of functional tasks. A second purpose was to assess the reliability of functional ROM measurements obtained by different raters using Dartfish software. Ten healthy participants, mean age 29 ± 5 years, were videotaped while performing five tasks selected from the Disabilities of the Arm, Shoulder and Hand (DASH). Video cameras and markers were used to obtain video images suitable for analysis in Dartfish software. Three repetitions of each task were performed. Shoulder movements from all three repetitions were analyzed using Dartfish software. The tracking tool of the Dartfish software was used to obtain shoulder joint angles and arcs of motion. Test-retest and inter-rater reliability of the measurements were evaluated using intraclass correlation coefficients (ICC). Maximum (coronal plane) abduction (118° ± 16°) and (sagittal plane) flexion (111° ± 15°) was observed during 'washing one's hair;' maximum extension (-68° ± 9°) was identified during 'washing one's own back.' Minimum shoulder ROM was observed during 'opening a tight jar' (33° ± 13° abduction and 13° ± 19° flexion). Test-retest reliability (ICC = 0.45 to 0.94) suggests high inter-individual task variability, and inter-rater reliability (ICC = 0.68 to 1.00) showed moderate to excellent agreement. KEY FINDINGS INCLUDE: 1) functional shoulder ROM identified in this study compared to similar studies; 2) healthy individuals require less than full ROM when performing five common ADL tasks 3) high participant variability was observed during performance of the five ADL tasks; and 4) Dartfish software provides a clinically relevant tool to analyze shoulder function.
Viggiani, Daniel; Gallagher, Kaitlin M; Sehl, Michael; Callaghan, Jack P
2017-11-01
Lumbar lordosis measures are poorly related to clinical low back pain, however using a controlled exposure such as prolonged standing to identify pain groups may clarify this relationship. The purpose of this study was to determine the distribution of lumbar intervertebral angles in asymptomatic persons who do (pain developers) and do not (non-pain developers) develop low back pain during standing. Sagittal plane lumbar spine radiographs of eight pain developers and eight non-pain developers were taken in three poses: upright standing, full extension and full flexion. Measures of vertebral end plate orientations from L1 to S1 were taken in each pose to compute: intervertebral angles, contribution of each level to the total curve, total lordosis, ranges of motion, relative pose positioning within the range of motion, vertebral shape, and lumbar spine recurve. Measures were compared between pain groups and lumbar levels. Pain group differences in intervertebral angles and level contributions were greatest in the full extension pose, with pain developers having greater contributions from higher lumbar levels and fewer contributions from lower levels than non-pain developers. Pain group differences in intervertebral angle distributions were less pronounced in upright standing and non-existent in full flexion. No other measures differentiated pain groups. Although participants had similar gross-lumbar spine curvature characteristics, non-pain developers have more curvature at lower levels in upright standing and full extension. These differences in regional vertebral kinematics may partially be responsible for standing-induced low back pain. Copyright © 2017 Elsevier Ltd. All rights reserved.
Invariant hip moment pattern while walking with a robotic hip exoskeleton.
Lewis, Cara L; Ferris, Daniel P
2011-03-15
Robotic lower limb exoskeletons hold significant potential for gait assistance and rehabilitation; however, we have a limited understanding of how people adapt to walking with robotic devices. The purpose of this study was to test the hypothesis that people reduce net muscle moments about their joints when robotic assistance is provided. This reduction in muscle moment results in a total joint moment (muscle plus exoskeleton) that is the same as the moment without the robotic assistance despite potential differences in joint angles. To test this hypothesis, eight healthy subjects trained with the robotic hip exoskeleton while walking on a force-measuring treadmill. The exoskeleton provided hip flexion assistance from approximately 33% to 53% of the gait cycle. We calculated the root mean squared difference (RMSD) between the average of data from the last 15 min of the powered condition and the unpowered condition. After completing three 30-min training sessions, the hip exoskeleton provided 27% of the total peak hip flexion moment during gait. Despite this substantial contribution from the exoskeleton, subjects walked with a total hip moment pattern (muscle plus exoskeleton) that was almost identical and more similar to the unpowered condition than the hip angle pattern (hip moment RMSD 0.027, angle RMSD 0.134, p<0.001). The angle and moment RMSD were not different for the knee and ankle joints. These findings support the concept that people adopt walking patterns with similar joint moment patterns despite differences in hip joint angles for a given walking speed. Copyright © 2011 Elsevier Ltd. All rights reserved.
Hiramatsu, Kunihiko; Mae, Tatsuo; Tachibana, Yuta; Nakagawa, Shigeto; Shino, Konsei
2018-02-01
The purpose of this study was to compare the femoral tunnel length, the femoral graft bending angle at the femoral tunnel aperture, and the contact area between the femoral tunnel wall and an interference screw used for fixation in anatomic rectangular tunnel anterior cruciate ligament (ACL) reconstruction (ART ACLR). The study included 149 patients with primary ACL injury who underwent ART ACLR. Preoperatively, flexion angle of the index knee was checked under general anaesthesia. Those of less than 130° of passive flexion were assigned to the outside-in (OI) technique (78 patients), while the others to the trans-portal inside-out (TP) technique (71 patients). The patients underwent computed tomography with multiplanar reconstruction at 3-5 weeks post-operatively. Femoral tunnel length, graft bending angle, and contact ratio between the IFS and femoral tunnel were assessed. P < 0.05 was considered statistically significant. The femoral tunnel length in the OI technique was significantly longer than that in the TP technique (P < 0.001). The femoral graft bending angle in the OI technique was significantly more acute than that in the TP technique (P < 0.001). The contact ratio in the OI technique was significantly larger than that in the TP technique at every point in the femoral tunnel (P < 0.001). The OI technique resulted in a more acute femoral graft bending angle, longer mean femoral tunnel length, and larger contact ratio than the TP technique after ART ACLR. Retrospective comparative study, Level III.
Kondo, Takashi; Muneta, Takeshi; Fukui, Tsutomu
2017-03-01
[Purpose] To investigate the relationship between the static measurement of the transverse arch of the forefoot, using a 3-dimensional (3D) foot scanner, and kinetics and kinematics of gait parameters in the sagittal plane. [Subjects and Methods] Twenty healthy subjects participated in this study. The transverse arch of the forefoot was measured under three conditions as follows: condition 1, sitting; condition 2, standing; and condition 3, foot forward and lower leg tilting anteriorly to the maximum position with heel contact. Gait parameters were recorded using a 3D motion analysis system and force plate. Correlation coefficients between TAF for each comparison of conditions and gait parameters were calculated using the Spearman correlation analysis. [Results] Rates of the transverse arch of the forefoot width and height between condition 2 and condition 3 were significantly correlated with the anterior and posterior component of ground reaction forces, the hip joint extension angle, and the ankle plantar flexion moment. [Conclusion] Our study's findings indicated that increased stiffness of the transverse arch of the forefoot was related to the increase in ankle plantar moment, and decreased stiffness of the transverse arch of the forefoot was related to the increase in hip joint extension angle during gait.
Kondo, Takashi; Muneta, Takeshi; Fukui, Tsutomu
2017-01-01
[Purpose] To investigate the relationship between the static measurement of the transverse arch of the forefoot, using a 3-dimensional (3D) foot scanner, and kinetics and kinematics of gait parameters in the sagittal plane. [Subjects and Methods] Twenty healthy subjects participated in this study. The transverse arch of the forefoot was measured under three conditions as follows: condition 1, sitting; condition 2, standing; and condition 3, foot forward and lower leg tilting anteriorly to the maximum position with heel contact. Gait parameters were recorded using a 3D motion analysis system and force plate. Correlation coefficients between TAF for each comparison of conditions and gait parameters were calculated using the Spearman correlation analysis. [Results] Rates of the transverse arch of the forefoot width and height between condition 2 and condition 3 were significantly correlated with the anterior and posterior component of ground reaction forces, the hip joint extension angle, and the ankle plantar flexion moment. [Conclusion] Our study’s findings indicated that increased stiffness of the transverse arch of the forefoot was related to the increase in ankle plantar moment, and decreased stiffness of the transverse arch of the forefoot was related to the increase in hip joint extension angle during gait. PMID:28356622
Miyake, Tamon; Kobayashi, Yo; Fujie, Masakatsu G; Sugano, Shigeki
2017-07-01
Gait training robots are useful for changing gait patterns and decreasing risk of trip. Previous research has reported that decreasing duration of the assistance or guidance of the robot is beneficial for efficient gait training. Although robotic intermittent control method for assisting joint motion has been established, the effect of the robot intervention timing on change of toe clearance is unclear. In this paper, we tested different timings of applying torque to the knee, employing the intermittent control of a gait training robot to increase toe clearance throughout the swing phase. We focused on knee flexion motion and designed a gait training robot that can apply flexion torque to the knee with a wire-driven system. We used a method of timing detecting for the robot conducting torque control based on information from the hip, knee, and ankle angles to establish a non-time dependent parameter that can be used to adapt to gait change, such as gait speed. We carried out an experiment in which the conditions were four time points: starting the swing phase, lifting the foot, maintaining knee flexion, and finishing knee flexion. The results show that applying flexion torque to the knee at the time point when people start lifting their toe is effective for increasing toe clearance in the whole swing phase.
Manning, William A; Ghosh, Kanishka; Blain, Alasdair; Longstaff, Lee; Deehan, David John
2017-06-01
Accurate soft tissue balance must be achieved to improve functional outcome after total knee arthroplasty (TKA). Sensor-integrated tibial trials have been introduced that allow real-time measurement of tibiofemoral kinematics during TKA. This study examined the interplay between tibiofemoral force and laxity, under defined intraoperative conditions, so as to quantify the kinematic behaviour of the CR femoral single-radius knee. TKA was undertaken in eight loaded cadaveric specimens. Computer navigation in combination with sensor data defined laxity and tibiofemoral contact force, respectively, during manual laxity testing. Fixed-effect linear modelling allowed quantification of the effect for flexion angle, direction of movement and TKA implantation upon the knee. An inverse relationship between laxity and contact force was demonstrated. With flexion, laxity increased as contact force decreased under manual stress. Change in laxity was significant beyond 30° for coronal plane laxity and beyond 60° for rotatory laxity (p < 0.01). Rotational stress in mid-flexion demonstrated the greatest mismatch in inter-compartmental forces. Contact point position over the tibial sensor demonstrated paradoxical roll-forward with knee flexion. Traditional balancing techniques may not reliably equate to uniform laxity or contact forces across the tibiofemoral joint through a range of flexion and argue for the role of per-operative sensor use to aid final balancing of the knee.
Lessi, Giovanna Camparis; Dos Santos, Ana Flávia; Batista, Luis Fylipe; de Oliveira, Gabriela Clemente; Serrão, Fábio Viadanna
2017-02-01
Muscle fatigue is associated with biomechanical changes that may lead to anterior cruciate ligament (ACL) injuries. Alterations in trunk and pelvis kinematics may also be involved in ACL injury. Although some studies have compared the effects of muscle fatigue on lower limb kinematics between men and women, little is known about its effects on pelvis and trunk kinematics. The aim of the study was to compare the effects of fatigue on lower limb, pelvis and trunk kinematics and muscle activation between men and women during landing. The participants included forty healthy subjects. We performed kinematic analysis of the trunk, pelvis, hip and knee and muscle activation analysis of the gluteal muscles, vastus lateralis and biceps femoris, during a single-leg landing before and after fatigue. Men had greater trunk flexion than women after fatigue. After fatigue, a decrease in peak knee flexion and an increase in Gmax and BF activation were observed. The increase in the trunk flexion can decrease the anterior tibiofemoral shear force resulted from the lower knee flexion angle, thereby decreasing the stress on the ACL. Copyright © 2016 Elsevier Ltd. All rights reserved.
Zhu, Zhonglin; Ding, Hui; Dang, Xiao; Tang, Jing; Zhou, Yixin; Wang, Guangzhi
2010-01-01
Fixed-bearing posterior-stabilized (PS) total knee arthroplasty (TKA) has been used in Asian countries for several years, but few studies have investigated differences in the kinematic properties of the patellar tendon after standard PS TKA as compared to high-flex PS TKA. To quantify the in vitro three-dimensional (3D) kinematics of the patellar tendon during passive high flexion and full extension before and after two different types of PS TKAs. Six fresh-frozen cadaveric knees were tested under the following conditions: the unaltered state, status-post traditional PS prostheses (Simth-nephew GENESIS II) replacement, and status-post high-flexion PS prostheses replacement. The soft tissue around the knee and the quadriceps muscle were preserved, then tested under the load of a specific weight in an Oxford knee rig. We designed a specialized rigid body with four active markers fixed to each bone to track the 3D passive motion of the cadaveric knees. Flexion and extension was controlled by the knee rig and captured by an Optotrak Certus high precision optical tracking system. The attachment sites of the patellar tendon were registered as virtual markers to calculate the 3D kinematics. The patellar tendon of the unaltered knee and both TKA knees showed similar deformation. We found the length of the patellar tendon changed significantly during a motion from full extension to 30°, but there was no significant change in length while undergoing a motion from 30° to full flexion. Both the sagittal plane and coronal plane angles of the patellar tendon decreased after PS TKAs. There was no significant difference in patellar tendon kinematics between the two types of PS TKAs. We believe the changes observed in the sagittal plane and coronal plane angles of the patellar tendon after PS TKAs may influence the extensor mechanism and be an important cause of patella-femoral complications. These data may be used to assess patella-femoral complications after surgery so as to improve the design of high-flexion TKAs for Asians and achieve long-term stability.
Kinematic Analysis of Line-Out Throwing in Elite International Rugby Union
Sayers, Mark G.L.
2011-01-01
The rugby union line-out is a key aspect of game play and involves players from both teams contesting for the ball after it has been thrown in from the side line. Successful lines-out throws require the ball to be delivered accurately to the hands of a jumping and/or lifted team mate (approximately 3-3.5 m off the ground) over distances of between 5- 18 m. Previous research has suggested considerable inter and intra-individual differences in the throwing techniques of international level players. Accordingly, this project investigated the interrelationships between accuracy and the line-out throwing characteristics of three elite international rugby players, and then analyzed whether these changed for throws over increasing length. Three-dimensional (3D) data were developed from video footage (50 Hz) of three elite international subjects for 30 throws over three distances (6 m, 10 m, and 15 m). Results showed notable differences between subjects in many variables at each of the key throw phases. However, several variables such as the degree of trunk flexion at the end of the backswing and at ball release, coupled with elbow flexion angle at ball release remained constant as throw length increased. All subjects exhibited high levels of consistency in movement patterns across all throw lengths. Findings indicated that these high performance line-out throwers shared several common characteristics that will provide useful guides in the development of training programs. Key points A key aspect of this research was the assessment of throwing accuracy using a functional throwing task that mimicked normal performance. Although individual differences in throwing technique occurred, several technical aspects of the throw were common to each of these elite international players. Subjects tended to be extremely consistent in the way they positioned the ball at the end of the backswing, and had very consistent elbow (flexion) and shoulder (flexion and abduction) angles at both the end of the backswing and at ball release. In addition, throwers kept the trunk close to upright during the throw with minimal trunk flexion or extension regardless of throw distance. To throw for longer distances participants tended to increase the involvement of the legs. PMID:24150632
Curran, Máire; O'Sullivan, Leonard; O'Sullivan, Peter; Dankaerts, Wim; O'Sullivan, Kieran
2015-11-01
This paper systematically reviews the effect of chair backrests and reducing seated hip flexion on low back discomfort (LBD) and trunk muscle activation. Prolonged sitting commonly exacerbates low back pain (LBP). Several modifications to seated posture and chair design have been recommended, including using chairs with backrests and chairs that reduce hip flexion. Electronic databases were searched by two independent assessors. Part 1 of this review includes 26 studies comparing the effect of sitting with at least two different hip angles. In Part 2, seven studies that compared the effect of sitting with and without a backrest were eligible. Study quality was assessed using the PEDro scale. Significant confounding variables and a relatively small number of randomized controlled trials (RCTs) involving people with LBP complicates analysis of the results. There was moderate evidence that chair backrests reduce paraspinal muscle activation, and limited evidence that chair backrests reduce LBD. There was no evidence that chairs involving less hip flexion reduce LBP or LBD, or consistently alter trunk muscle activation. However, participants in several studies subjectively preferred the modified chairs involving less hip flexion. The limited evidence to support the use of chairs involving less seated hip flexion, or the effect of a backrest, is consistent with the limited evidence that other isolated chair design features can reduce LBP. LBP management is likely to require consideration of several factors in addition to sitting position. Larger RCTs involving people with LBP are required. © 2015, Human Factors and Ergonomics Society.
Roth, Joshua D; Howell, Stephen M; Hull, Maury L
2015-10-21
Gap-balancing is an alignment method for total knee arthroplasty with the goal of creating uniform tension in the periarticular soft-tissue restraints and equal laxities throughout the arc of flexion. However, there is little evidence that achieving equal laxities prevents either overly tight or overly loose soft-tissue restraints after total knee arthroplasty. Accordingly, the purpose of the present study was to determine whether the laxities at 0°, 45°, and 90° of flexion are equal in the native knee. Seven different laxities were measured at 0°, 45°, and 90° of flexion in ten fresh-frozen native cadaveric knees (with intact menisci, cartilage, and ligaments) by applying loads of ±5 Nm in varus-valgus rotation, ±3 Nm in internal-external rotation, 100 N in distraction, and ±45 N in anterior-posterior translation with use of a six-degrees-of-freedom load application system. The mean laxities (and standard deviations) at 45° of flexion were 1.7° ± 0.6° greater in varus, 0.9° ± 0.4° greater in valgus, 10.2° ± 2.7° greater in internal rotation, 10.1° ± 2.0° greater in external rotation, 1.7 ± 1.0 mm greater in distraction translation, and 3.3 ± 1.5 mm greater in anterior translation than those at 0° of flexion. The mean laxities at 90° of flexion were 2.5° ± 0.8° greater in varus, 1.0° ± 0.5° greater in valgus, 10.0° ± 4.6° greater in internal rotation, 10.1° ± 4.5° greater in external rotation, 1.8 ± 0.7 mm greater in distraction, and 1.6 ± 1.2 mm greater in anterior translation than those at 0° of flexion. The mean anterior translation at 90° of flexion was 1.7 ± 0.9 mm less than that at 45° of flexion. Because five of the seven laxities were at least 1.7° or 1.6 mm greater at both 45° and 90° of flexion than those at 0° of flexion, the laxities of the native knee measured in this study are unequal at these flexion angles and therefore do not support the goal of gap-balancing in total knee arthroplasty. One possible disadvantage of changing the native laxities at 45° and 90° of flexion to match those at 0° of flexion in a total knee arthroplasty is the overly tight soft-tissue restraints relative to those of the native knee, which patients may perceive as pain, stiffness, and/or limited flexion. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.
49 CFR 572.135 - Upper and lower torso assemblies and torso flexion test procedure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... orientation angle may not exceed 20 degrees. (8) Attach the pull cable and the load cell as shown in Figure O4. (9) Apply a tension force in the midsagittal plane to the pull cable as shown in Figure O4 at any...
Passive moment about the hip in straight leg raising.
Lee, R Y; Munn, J
2000-06-01
The purpose of this examine is to study the load-deformation characteristics of the hip in straight leg raising. An experimental study in which passive moment about the hip was determined as a function of hip angle. Straight leg raising is widely employed in clinical examination, and there is little information on its mechanical characteristics. Fourteen healthy volunteers were recruited for this study. Three trials of straight leg raise tests were performed while subjects lay supine on a plinth that was fitted with load cells. An electrogoniometer was employed to measure hip flexion during the test. Resistive moment at the hip was determined using a dynamic biomechanical model. The present experimental method was shown to be highly reliable. The moment-angle curves of all subjects were shown to follow an exponential function. Stiffness and strain energy of posterior hip tissues could be derived from the moment-angle curves. Evaluation of such elastic properties is clinically important as they may be altered with injuries of the tissues. Clinically, contracture of hamstring muscles and other posterior hip tissues is evaluated by measuring the available range of hip flexion in straight leg raising. However, this does not provide any information on the elastic properties of the tissues. The present study reports a reliable method of evaluating such properties.
Effects of general principles of person transfer techniques on low back joint extension moment.
Katsuhira, Junji; Yamasaki, Syun; Yamamoto, Sumiko; Maruyama, Hitoshi
2010-01-01
The purpose of this study was to examine the effects of general principles of person transfer techniques specifically on the low back joint extension moment. These effects were examined by the following measurable quantitative parameters: 1) trunk bending angle, 2) knee flexion angle, 3) distance between the centers of gravity (COGs) of the caregiver and patient, representing the distance between the caregiver and patient, and 4) the vertical component of the ground reaction force representing the amount of the weight-bearing load on the caregiver's low back during transfers with and without assistive devices. Twenty students each took the role of caregiver, and one healthy adult simulated a patient. The participants performed three different transfer tasks: without any assistive device, with the patient wearing a low back belt, and with the caregiver using a transfer board. We found that the distance between the COGs and the vertical component of the ground reaction force, but not the trunk bending and knee flexion angles, were the variables that affected the low back joint extension moment. Our results suggest that the general principle of decreasing the distance between COGs is most effective for decreasing the low back joint extension moment during transfers under all conditions.
Häberli, Janosch; Voumard, Benjamin; Kösters, Clemens; Delfosse, Daniel; Henle, Philipp; Eggli, Stefan; Zysset, Philippe
2018-06-01
Dynamic intraligamentary stabilization (DIS) is a primary repair technique for acute anterior cruciate ligament (ACL) tears. For internal bracing of the sutured ACL, a metal spring with 8 mm maximum length change is preloaded with 60-80 N and fixed to a high-strength polyethylene braid. The bulky tibial hardware results in bone loss and may cause local discomfort with the necessity of hardware removal. The technique has been previously investigated biomechanically; however, the amount of spring shortening during movement of the knee joint is unknown. Spring shortening is a crucial measure, because it defines the necessary dimensions of the spring and, therefore, the overall size of the implant. Seven Thiel-fixated human cadaveric knee joints were subjected to passive range of motion (flexion/extension, internal/external rotation in 90° flexion, and varus/valgus stress in 0° and 20° flexion) and stability tests (Lachman/KT-1000 testing in 0°, 15°, 30°, 60°, and 90° flexion) in the ACL-intact, ACL-transected, and DIS-repaired state. Kinematic data of femur, tibia, and implant spring were recorded with an optical measurement system (Optotrak) and the positions of the bone tunnels were assessed by computed tomography. Length change of bone tunnel distance as a surrogate for spring shortening was then computed from kinematic data. Tunnel positioning in a circular zone with r = 5 mm was simulated to account for surgical precision and its influence on length change was assessed. Over all range of motion and stability tests, spring shortening was highest (5.0 ± 0.2 mm) during varus stress in 0° knee flexion. During flexion/extension, spring shortening was always highest in full extension (3.8 ± 0.3 mm) for all specimens and all simulations of bone tunnels. Tunnel distance shortening was highest (0.15 mm/°) for posterior femoral and posterior tibial tunnel positioning and lowest (0.03 mm/°) for anterior femoral and anterior tibial tunnel positioning. During passive flexion/extension, the highest spring shortening was consistently measured in full extension with a continuous decrease towards flexion. If preloading of the spring is performed in extension, the spring can be downsized to incorporate a maximum length change of 5 mm resulting in a smaller implant with less bone sacrifice and, therefore, improved conditions in case of revision surgery.
Development of a parametric kinematic model of the human hand and a novel robotic exoskeleton.
Burton, T M W; Vaidyanathan, R; Burgess, S C; Turton, A J; Melhuish, C
2011-01-01
This paper reports the integration of a kinematic model of the human hand during cylindrical grasping, with specific focus on the accurate mapping of thumb movement during grasping motions, and a novel, multi-degree-of-freedom assistive exoskeleton mechanism based on this model. The model includes thumb maximum hyper-extension for grasping large objects (~> 50 mm). The exoskeleton includes a novel four-bar mechanism designed to reproduce natural thumb opposition and a novel synchro-motion pulley mechanism for coordinated finger motion. A computer aided design environment is used to allow the exoskeleton to be rapidly customized to the hand dimensions of a specific patient. Trials comparing the kinematic model to observed data of hand movement show the model to be capable of mapping thumb and finger joint flexion angles during grasping motions. Simulations show the exoskeleton to be capable of reproducing the complex motion of the thumb to oppose the fingers during cylindrical and pinch grip motions. © 2011 IEEE
NASA Astrophysics Data System (ADS)
Zin, Muhammad Athif Mat; Rambely, Azmin Sham; Ariff, Noratiqah Mohd
2018-04-01
The purpose of the study was to determine the effects of increment of loads to lower extremity joints during the two-hand kettlebell swing (KS) activity with loads of 4 kg, 6 kg and 8 kg. Three male adults participated in this study. Subjects were required to perform a two-hand KS with three different loads which were 4 kg, 6 kg and 8 kg. A Vicon Nexus system (v1.5.2) with three infrared cameras adjusted with 100 Hz speed were used to capture KS motion to produce kinematics data for lower extremity joints which were ankle, knee and hip joints. The results showed that mean maximum flexion angle (MFA) of ankle, knee and hip joints decreased as load increased. Mean MFA of knee joint was the highest while mean MFA of ankle joint was the smallest recorded. Mean MFA of ipsilateral leg was higher than that of contralateral leg for a right-dominant subject.
Ochi, Kensuke; Horiuchi, Yukio; Tanabe, Aya; Morita, Kozo; Takeda, Kentaro; Ninomiya, Ken
2011-05-01
To compare the shoulder internal rotation test-a new, provocative test-with the elbow flexion test in the diagnosis of cubital tunnel syndrome (CubTS). Twenty-five patients with CubTS were examined before and after surgery with 10 seconds each of the elbow flexion and shoulder internal rotation tests. Fifty-four asymptomatic individuals and 14 neuropathy patients with a diagnosis other than CubTS were also examined as control cases. For the shoulder internal rotation test, the patient's upper extremity was kept at 90° abduction, maximum internal rotation, and 10° flexion at the shoulder, with 90° elbow flexion and neutral position of the forearm and wrist, with finger extension. Test results were considered positive if any slight symptom attributable to CubTS occurred within 10 seconds. Extraneural pressure inside the cubital tunnel was intraoperatively measured with the positions of both the elbow flexion and shoulder internal rotation tests, in 15 of the CubTS cases. Statistical analyses were performed using Student's t-test with a confidence level of 95%. The preoperative sensitivity in CubTS cases was 80% in the 10-second shoulder internal rotation test and 36% in the 10-second elbow flexion test, and these differences were significant. None of the control cases had positive results in either test. All the CubTS cases improved with surgery; after surgery, neither test provoked symptoms in any surgical patient. The extraneural pressure increased in both provocative positions with no significant difference. Positive results for the 10-second shoulder internal rotation test were more sensitive than that for the elbow flexion test of the same duration and seemed specific to CubTS. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Knee Control and Jump-Landing Technique in Young Basketball and Floorball Players.
Leppänen, M; Pasanen, K; Kulmala, J-P; Kujala, U M; Krosshaug, T; Kannus, P; Perttunen, J; Vasankari, T; Parkkari, J
2016-04-01
Poor knee alignment is associated with increased loading of the joints, ligaments and tendons, and may increase the risk of injury. The study purpose was to compare differences in knee kinematics between basketball and floorball players during a vertical drop jump (VDJ) task. We wanted to investigate whether basketball players, whose sport includes frequent jump-landings, exhibited better knee control compared with floorball players, whose sport involves less jumping. Complete data was obtained from 173 basketball and 141 floorball players. Peak knee valgus and flexion angles during the VDJ were analyzed by 3D motion analysis.Larger knee valgus angles were observed among basketball players (- 3.2°, 95%CI -4.5 to - 2.0) compared with floorball players (- 0.9°, 95%CI -2.3 to 0.6) (P=0.022). Basketball players landed with a decreased peak knee flexion angle (83.1°, 95%CI 81.4 to 84.8) compared with floorball players (86.5°, 95%CI 84.6 to 88.4) (P=0.016). There were no significant differences in height, weight or BMI between basketball and floorball players. Female athletes exhibited significantly greater valgus angles than males. This study revealed that proper knee control during jump-landing does not seem to develop in young athletes simply by playing the sport, despite the fact that jump-landings occur frequently in practice and games. © Georg Thieme Verlag KG Stuttgart · New York.
Mukhopadhyay, Prabir; O'Sullivan, Leonard W; Gallwey, Timothy J
2009-05-01
Twenty-seven right-handed male university students participated in this study, which comprised a full factorial model consisting of three forearm rotation angles (60% prone and supine and neutral range of motion), three elbow angles (45 degrees , 90 degrees and 135 degrees ), three upper arm angles (45 degrees flexion/extension and neutral), one exertion frequency (15 per min) and one level of pronation torque (20% maximum voluntary contraction (MVC) relative to MVC at each articulation). Discomfort rating after the end of each 5 min treatment was recorded on a visual analogue scale. Results of a repeated measures analysis of covariance on discomfort score, with torque endurance time as covariate, indicated that none of the factors was significant including torque endurance time (p = 0.153). An initial data collection phase preceded the main experiment in order to ensure that participants exerted exactly 20% MVC of the particular articulation. In this phase MVC pronation torque was measured at each articulation. The data revealed a significant forearm rotation angle effect (p = 0.001) and participant effect (p = 0.001). Of the two-way interactions, elbow*participant (p = 0.004), forearm*participant (p = 0.001) and upper arm*participant (p = 0.005) were the significant factors. Electromyographic activity of the pronator teres and biceps brachii muscles revealed no significant change in muscle activity in most of the articulations. Industrial jobs involving deviated upper arm postures are typical in industry but have a strong association with injury. Data from this study will enable better understanding of the effects of deviated upper arm postures on musculoskeletal disorders and can also be used to identify and control high-risk tasks in industry.
Suzuki, Hidetomo; Omori, Go; Uematsu, Daisuke; Nishino, Katsutoshi; Endo, Naoto
2015-10-01
A smaller knee flexion angle and larger knee valgus angle during weight-bearing activities have been identified as risk factors for non-contact anterior cruciate ligament (ACL) injuries. To prevent such injuries, attention has been focused on the role of hip strength in knee motion control. However, gender differences in the relationship between hip strength and knee kinematics during weight-bearing activities in the frontal plane have not been evaluated. The purpose of this study was to determine the influence of hip strength on knee kinematics in both genders during a single-legged landing task in the frontal plane. The hypotheses were that 1) subjects with a greater hip strength would demonstrate larger knee flexion and smaller knee valgus and internal rotation angles and 2) no gender differences would exist during the single-legged landing task. Forty-three Japanese collegiate basketball players (20 males, 23 females) participated in this study. Three-dimensional motion analysis was used to evaluate knee kinematics during a single-legged medial drop landing (SML). A hand-held dynamometer was used to assess hip extensor (HEXT), abductor (HAB), and external rotator (in two positions: seated position [SHER] and prone [PHER]) isometric strength. Spearman rank correlation coefficients (ρ) were determined for correlations between hip strength and knee kinematics at initial contact (IC) and peak (PK) during SML (p < 0.05). Negative correlations were observed between the knee valgus angle at IC and HEXT (ρ = -0.48, p = 0.02), HAB (ρ = -0.46, p = 0.03) and PHER (ρ = -0.44, p = 0.04) strength in females. In addition, a significant positive correlation was observed between the knee flexion angle at PK and HEXT strength (ρ = 0.61, p = 0.004) in males. Significant correlations between hip strength and knee kinematics during SML were observed in both genders. Hip strength may, therefore, play an important role in knee motion control during sports activities, suggesting that increased hip strength may help to prevent non-contact ACL injuries in athletes of both genders. Moreover, gender-specific programs may be needed to control abnormal knee motion, as the influence of hip strength on knee kinematics may differ based on gender. 3.
2008-03-31
angle. • Arm Horizontal Plane Adduction o Place the participant’s dominant shoulder in 30° of flexion. o Have the participant flex their elbow to...approximately 90° of flexion. o Have the forearm rotated into the mid-position between supination and pronation. o Have the inclinometer near the elbow ...Grenade Toss Participants were required to toss a tennis ball like a grenade from the prone position to a target approximately 15 m away
Shimokochi, Yohei; Ambegaonkar, Jatin P.; Meyer, Eric G.
2016-01-01
Context: Ground reaction force (GRF) and tibiofemoral force magnitudes and directions have been shown to affect anterior cruciate ligament loading during landing. However, the kinematic and kinetic factors modifying these 2 forces during landing are unknown. Objective: To clarify the intersegmental kinematic and kinetic links underlying the alteration of the GRF and tibiofemoral force vectors secondary to changes in the sagittal-plane body position during single-legged landing. Design: Crossover study. Setting: Laboratory. Patients or Other Participants: Twenty recreationally active participants (age = 23.4 ± 3.6 years, height = 171.0 ± 9.4 cm, mass = 73.3 ± 12.7 kg). Intervention(s): Participants performed single-legged landings using 3 landing styles: self-selected landing (SSL), body leaning forward and landing on the toes (LFL), and body upright with flat-footed landing (URL). Three-dimensional kinetics and kinematics were recorded. Main Outcome Measure(s): Sagittal-plane tibial inclination and knee-flexion angles, GRF magnitude and inclination angles relative to the tibia, and proximal tibial forces at peak tibial axial forces. Results: The URL resulted in less time to peak tibial axial forces, smaller knee-flexion angles, and greater magnitude and a more anteriorly inclined GRF vector relative to the tibia than did the SSL. These changes led to the greatest peak tibial axial and anterior shear forces in the URL among the 3 landing styles. Conversely, the LFL resulted in longer time to peak tibial axial forces, greater knee-flexion angles, and reduced magnitude and a more posteriorly inclined GRF vector relative to the tibia than the SSL. These changes in LFL resulted in the lowest peak tibial axial and largest posterior shear forces among the 3 landing styles. Conclusions: Sagittal-plane intersegmental kinematic and kinetic links strongly affected the magnitude and direction of GRF and tibiofemoral forces during the impact phase of single-legged landing. Therefore, improving sagittal-plane landing mechanics is important in reducing harmful magnitudes and directions of impact forces on the anterior cruciate ligament. PMID:27723362
Miyaguchi, Kazuyoshi; Demura, Shinichi
2006-05-01
The purpose of this study was to examine the output properties of muscle power by the dominant upper limb using SSC, and the relationships between the power output by SSC and a one-repetition maximum bench press (1 RM BP) used as a strength indicator of the upper body. Sixteen male athletes (21.4+/-0.9 yr) participated in this study. They pulled a load of 40% of maximum voluntary contraction (MVC) at a stretch by elbow flexion of the dominant upper limb in the following three preliminary conditions: static relaxed muscle state (SR condition), isometric muscle contraction state (ISO condition), and using SSC (SSC condition). The velocity with a wire load via a pulley during elbow flexion was measured accurately using a power instrument with a rotary encoder, and the muscle power curve was drawn from the product of the velocity and load. Significant differences were found among all evaluation parameters of muscle power exerted from the above three conditions and the parameters regarding early power output during concentric contraction were larger in the SSC condition than the SR and ISO conditions. The parameters on initial muscle contraction velocity when only using SSC significantly correlated with 1 RM BP (r=0.60-0.62). The use of SSC before powerful elbow flexion may contribute largely to early explosive power output during concentric contraction. Bench press capacity relates to a development of the above early power output when using SSC.
12 weeks of simulated barefoot running changes foot-strike patterns in female runners.
McCarthy, C; Fleming, N; Donne, B; Blanksby, B
2014-05-01
To investigate the effect of a transition program of simulated barefoot running (SBR) on running kinematics and foot-strike patterns, female recreational athletes (n=9, age 29 ± 3 yrs) without SBR experience gradually increased running distance in Vibram FiveFingers SBR footwear over 12 weeks. Matched controls (n=10, age 30 ± 4 yrs) continued running in standard footwear. A 3-D motion analysis of treadmill running at 12 km/h(-1) was performed by both groups, barefoot and shod, pre- and post-intervention. Post-intervention data indicated a more-forefoot strike pattern in the SBR group compared to controls; both running barefoot (P>0.05), and shod (P<0.001). When assessed barefoot, there were significant kinematic differences across time in the SBR group for ankle flexion angle at toe-off (P<0.01). When assessed shod, significant kinematic changes occurred across time, for ankle flexion angles at foot-strike (P<0.001) and toe-off (P<0.01), and for range of motion (ROM) in the absorptive phase of stance (P<0.01). A knee effect was recorded in the SBR group for flexion ROM in the absorptive phase of stance (P<0.05). No significant changes occurred in controls. Therefore, a 12-week transition program in SBR could assist athletes seeking a more-forefoot strike pattern and "barefoot" kinematics, regardless of preferred footwear. © Georg Thieme Verlag KG Stuttgart · New York.
Hanten, W P; Chandler, S D
1994-09-01
Experimental evidence does not currently exist to support the claims of clinical effectiveness for myofascial release techniques. This presents an obvious need to document the effects of myofascial release. The purpose of this study was to compare the effects of two techniques, sagittal plane isometric contract-relax and myofascial release leg pull for increasing hip flexion range of motion (ROM) as measured by the angle of passive straight-leg raise. Seventy-five nondisabled, female subjects 18-29 years of age were randomly assigned to contract-relax, leg pull, or control groups. Pretest hip flexion ROM was measured for each subject's right hip with a passive straight-leg raise test using a fluid-filled goniometer. Subjects in the treatment groups received either contract-relax or leg pull treatment applied to the right lower extremity; subjects in the control group remained supine quietly for 5 minutes. Following treatment, posttest straight-leg raise measurements were performed. A one-way analysis of variance followed by a Newman-Keuls post hoc comparison of mean gain scores showed that subjects receiving contract-relax treatment increased their ROM significantly more than those who received leg pull treatment, and the increase in ROM of subjects in both treatment groups was significantly higher than those of the control group. The results suggest that while both contract-relax and leg pull techniques can significantly increase hip flexion ROM in normal subjects, contract-relax treatment may be more effective and efficient than leg pull treatment.
Hou, Jiateng; Sun, Yingfei; Sun, Lixin; Pan, Bingyu; Huang, Zhipei; Wu, Jiankang; Zhang, Zhiqiang
2016-01-01
This paper proposes a neuromusculoskeletal (NMS) model to predict individual muscle force during elbow flexion and extension. Four male subjects were asked to do voluntary elbow flexion and extension. An inertial sensor and surface electromyography (sEMG) sensors were attached to subject's forearm. Joint angle calculated by fusion of acceleration and angular rate using an extended Kalman filter (EKF) and muscle activations obtained from the sEMG signals were taken as the inputs of the proposed NMS model to determine individual muscle force. The result shows that our NMS model can predict individual muscle force accurately, with the ability to reflect subject-specific joint dynamics and neural control solutions. Our method incorporates sEMG and motion data, making it possible to get a deeper understanding of neurological, physiological, and anatomical characteristics of human dynamic movement. We demonstrate the potential of the proposed NMS model for evaluating the function of upper limb movements in the field of neurorehabilitation. PMID:27916853
Iino, Yoichi; Kojima, Takeji
2012-08-01
This study investigated the validity of the top-down approach of inverse dynamics analysis in fast and large rotational movements of the trunk about three orthogonal axes of the pelvis for nine male collegiate students. The maximum angles of the upper trunk relative to the pelvis were approximately 47°, 49°, 32°, and 55° for lateral bending, flexion, extension, and axial rotation, respectively, with maximum angular velocities of 209°/s, 201°/s, 145°/s, and 288°/s, respectively. The pelvic moments about the axes during the movements were determined using the top-down and bottom-up approaches of inverse dynamics and compared between the two approaches. Three body segment inertial parameter sets were estimated using anthropometric data sets (Ae et al., Biomechanism 11, 1992; De Leva, J Biomech, 1996; Dumas et al., J Biomech, 2007). The root-mean-square errors of the moments and the absolute errors of the peaks of the moments were generally smaller than 10 N·m. The results suggest that the pelvic moment in motions involving fast and large trunk movements can be determined with a certain level of validity using the top-down approach in which the trunk is modeled as two or three rigid-link segments.
Design, simulation and modelling of auxiliary exoskeleton to improve human gait cycle.
Ashkani, O; Maleki, A; Jamshidi, N
2017-03-01
Exoskeleton is a walking assistance device that improves human gait cycle through providing auxiliary force and transferring physical load to the stronger muscles. This device takes the natural state of organ and follows its natural movement. Exoskeleton functions as an auxiliary device to help those with disabilities in hip and knee such as devotees, elderly farmers and agricultural machinery operators who suffer from knee complications. In this research, an exoskeleton designed with two screw jacks at knee and hip joints. To simulate extension and flexion movements of the leg joints, bearings were used at the end of hip and knee joints. The generated torque and motion angles of these joints obtained as well as the displacement curves of screw jacks in the gait cycle. Then, the human gait cycle was simulated in stance and swing phases and the obtained torque curves were compared. The results indicated that they followed the natural circle of the generated torque in joints with a little difference from each other. The maximum displacement obtained 4 and 6 cm in hip and knee joints jack respectively. The maximum torques in hip and knee joints were generated in foot contact phase. Also the minimum torques in hip and knee joints were generated in toe off and heel off phases respectively.
In vivo imaging of superficial femoral artery (SFA) stents for deformation analysis
NASA Astrophysics Data System (ADS)
Ganguly, A.; Schneider, A.; Keck, B.; Bennett, N. R.; Fahrig, R.
2008-03-01
A high-resolution (198 μm) C-arm CT imaging system (Axiom Artis dTA, Siemens Medical Solutions, Forchheim, Germany) was optimized for imaging superficial femoral artery (SFA) stents in humans. The SFA is susceptible to the development of atherosclerotic lesions. These are typically treated with angioplasty and stent deployment. However, these stents can have a fracture rate as high as 35%. Fracture is usually accompanied by restenosis and reocclusion. The exact cause of breakage is unknown and is hypothesized to result from deforming forces due to hip and knee flexion. Imaging was performed with the leg placed in both straight and bent positions. Projection images obtained during 20 s scans with ~200° of rotation of the C-arm were back-projected to obtain 3D volumes. Using a semi-automatic software algorithm developed in-house, the stent centerlines were found and ellipses were fitted to the slice normals. Image quality was adequate for calculations in 11/13 subjects. Bending the leg was found to shorten the stents in 10/11 cases with the maximum change being 9% (12 mm in a 133 mm stent), and extend the stent in one case by 1.6%. The maximum eccentricity change was 36% with a bend angle of 72° in a case where the stent extended behind the knee.
Baltzopoulos, Vasilios; Richards, Paula J.; Maganaris, Constantinos N.
2011-01-01
The purpose of this study was to determine the effect of dynamometer and joint axis misalignment on measured isometric knee-extension moments using inverse dynamics based on the actual joint kinematic information derived from the real-time X-ray video and to compare the errors when the moments were calculated using measurements from external anatomical surface markers or obtained from the isokinetic dynamometer. Six healthy males participated in this study. They performed isometric contractions at 90° and 20° of knee flexion, gradually increasing to maximum effort. For the calculation of the actual knee-joint moment and the joint moment relative to the knee-joint center, determined using the external marker, two free body diagrams were used of the Cybex arm and the lower leg segment system. In the first free body diagram, the mean center of the circular profiles of the femoral epicondyles was used as the knee-joint center, whereas in the second diagram, the joint center was assumed to coincide with the external marker. Then, the calculated knee-joint moments were compared with those measured by the dynamometer. The results indicate that 1) the actual knee-joint moment was different from the dynamometer recorded moment (difference ranged between 1.9% and 4.3%) and the moment calculated using the skin marker (difference ranged between 2.5% and 3%), and 2) during isometric knee extension, the internal knee angle changed significantly from rest to the maximum contraction state by about 19°. Therefore, these differences cannot be neglected if the moment–knee-joint angle relationship or the muscle mechanical properties, such as length-tension relationship, need to be determined. PMID:21474701
Yonetsu, Ryo; Iwata, Akira; Surya, John; Unase, Kazunori; Shimizu, Junichi
2015-01-01
This study was designed to provide a better understanding of how a single neurodevelopmental treatment (NDT) session affects sit-to-stand (STS) movements in children with cerebral palsy (CP). Eight children with spastic diplegia and five typically developing children, aged 4-6 years, participated in this study. The CP participants performed STS movements immediately before and after a 40-min NDT session. Using a three-dimensional, four-camera analysis system, angular movements involving the hip, knee and ankle joints of the participants were obtained. During forward tilt of the trunk, the maximum and final angles after the NDT session significantly decreased compared with those before the session (p < 0.05, p < 0.01). Moreover, the final hip flexion after the session also significantly decreased compared with that before the session (p < 0.01). On the other hand, the initial, maximum and final ankle dorsiflexion angles after the session were significantly greater (p < 0.05, p < 0.01 and p < 0.05, respectively) than before the session. These findings suggest that a single NDT session enables children with CP to stand from a seated position without using some atypical movement patterns. Preschool-aged children with spastic diplegia, with limited ability to independently transfer from a sitting position, and dependent on a wheelchair for mobility experience obstacles to enhanced activities of daily life and social participation. A single neurodevelopmental treatment session would enable children with spastic diplegia to perform sit-to-stand movements more efficiently, with selective muscle control. Understanding how a single neurodevelopmental treatment session affects sit-to-stand movements in children with spastic diplegia is invaluable for therapists planning more efficient therapeutic programs and may enable children with spastic diplegia to develop improved mobility.
Lange, G W; Hintermeister, R A; Schlegel, T; Dillman, C J; Steadman, J R
1996-05-01
Muscle activity, joints, angles, and heart rate during uphill walking were compared for application in knee rehabilitation. The objectives of this study were to quantify muscle activation levels at different treadmill grades and to determine the grade(s) at which knee range of motion would not further compromise the joint. Average and peak electromyographic activity of the quadriceps (vastus medialis oblique and vastus lateralis) and hamstrings (biceps femoris and medial hamstrings (semimembranosus/semitendinosus)] was recorded during walking at 0, 12, and 24% grade. Six subjects (age = 28.5 +/- 3.7 years, stature = 1.79 +/- .05 m, and mass = 74.7 +/- 7.9 kg) walked at self-selected speeds at each grade while ankle, knee and hip angles, heart rate, and electromyographic activity (surface electrodes) were recorded. Maximum voluntary contractions provided a relative reference for the electromyographic activity during walking. Average and peak electromyographic activity increased significantly across grades for the vastus medialis oblique (125 and 154%), vastus lateralis (109 and 139%), and biceps femoris (53 and 46%), but remained similar for the medial hamstrings. Maximum knee flexion at heel strike increased significantly with grade. Despite decreased self-selected speeds with increasing grade, there were significant increases in heart rate across grades. The results of this study provide a basic understanding of the quadriceps and hamstrings activity levels, lower extremity joint range of motion, and cardiovascular requirements of graded treadmill walking in normal subjects. The results also suggest that a grade just greater than 12% may be most beneficial for knee rehabilitation to minimize patellofemoral discomfort or potential strain on the anterior cruciate ligament. The benefits achieved through this functional activity encourage its implementation in rehabilitation and provide a basis for comparison with injured patients.
Poor results of radio-scaphoid capsulodesis for scapholunate dissociation.
Finsen, Vilhjalmur; Borchgrevink, Grethe Elisabeth
2013-01-01
We reviewed 17 patients 64 (range 29-123) months after dorsal radioscaphoid capsulodesis for scapholunate dissociation. Mean loss of key pinch was 13%, grip strength 18%, wrist flexion 22% (p < 0.001), and total wrist ROM 17% (p < 0.005). VAS (0 = best; 100 = worst) was 30(±28) for pain, 43(±30) for function, and 33(±33) for general satisfaction with the outcome. Mean Quick-DASH and PRWE scores were 27 and 34, respectively. The mean scapholunate gap was 3.5 mm before surgery, 1.9 mm after surgery, and 3.3 mm at review. The corresponding scapholunate angles were 63°, 46°, and 70°, respectively. The mean radioscaphoid angle with the wrist maximally flexed was 84° (69-99) for the patients and was 91° (77-103) in ten wrists of volunteers. Six patients had changed their jobs because of the wrist. Three patients stated that they would not have consented to operation if they had known the outcome in advance. Radioscaphoid capsulodesis does not prevent volar flexion of the scaphoid.
Rowe, Justin B.; Friedman, Nizan; Bachman, Mark; Reinkensmeyer, David J.
2014-01-01
This paper describes the design and pilot testing of a novel device for unobtrusive monitoring of wrist and hand movement through a sensorized watch and a magnetic ring system called the manumeter. The device senses the magnetic field of the ring through two triaxial magnetometers and records the data to onboard memory which can be analyzed later by connecting the watch unit to a computer. Wrist and finger joint angles are estimated using a radial basis function network. We compared joint angle estimates collected using the manumeter to direct measurements taken using a passive exoskeleton and found that after a 60 minute trial, 95% of the radial/ulnar deviation, wrist flexion/extension and finger flexion/extension estimates were within 2.4, 5.8, and 4.7 degrees of their actual values respectively. The device measured angular distance traveled for these three joints within 10.4%, 4.5%, and 14.3 % of their actual values. The manumeter has potential to improve monitoring of real world use of the hand after stroke and in other applications. PMID:24187216
Briggs, Andrew; Straker, Leon; Greig, Alison
2004-06-10
The objective of this study was to quantitatively analyse the sitting posture of school children interacting with both old (book) and new (laptop and desktop computers) information technologies to test the hypothesis that posture is effected by the type of information technology (IT) used. A mixed model design was used to test the effect of IT type (within subjects) and age and gender (between subjects). The sitting posture of 32 children aged 4-17 years was measured whilst they read from a book, laptop, and desktop computer at a standard school chair and desk. Video images were captured and then digitized to calculate mean angles for head tilt, neck flexion, trunk flexion, and gaze angle. Posture was found to be influenced by IT type (p < 0.001), age (p < 0.001) and gender (p = 0.024) and significantly correlated to the stature of the participants. Measurement of resting posture and the maximal range of motion of the upper and lower cervical spines in the sagittal plane was also undertaken. The biophysical impact and the suitability of the three different information technologies are discussed.
Influence of training on the biokinematics in trotting Andalusian horses.
Cano, M R; Miró, F; Diz, A M; Agüera, E; Galisteo, A M
2000-11-01
The aim of this study was to determine the influence of a 10-month training programme on the linear, temporal and angular characteristics of the fore and hind limbs at the trot in the Andalusian horse, using standard computer-aided videography. Sixteen male Andalusian horses were observed before and after training. Six strides were randomly selected for analysis in each horse and linear, temporal and angular parameters were calculated for fore and hind limbs. The training programme used here produced significant changes in kinematic parameters, such as shortening of stride length, and increase in swing duration and a decrease in hind limb stance percentage. No significant differences were recorded in the angular values for the forelimb joints. In trained horses, the more proximal joints of the hind limb, especially the hip and stifle, had a greater flexion while the fetlock showed a smaller extension angle. At the beginning of the swing phase, hip and stifle joints presented angles that were significantly more flexed. When the hind limbs came into contact with the ground, all the joints presented greater flexion after training.
Xu, Yan; Liu, Jianyu; Kramer, Scott; Martins, Cesar; Kato, Yuki; Linde-Rosen, Monica; Smolinski, Patrick; Fu, Freddie H
2011-02-01
High tunnel placement is common in single- and double-bundle anterior cruciate ligament (ACL) reconstructions. Similar nonanatomic tunnel placement may also occur in ACL augmentation surgery. In this study, in situ forces and knee kinematics were compared between nonanatomic high anteromedial (AM) and anatomic AM augmentation in a knee with isolated AM bundle injury. Controlled laboratory study. Seven fresh-frozen cadaver knees were used (age, 48 ± 12.5 years). First, intact knee kinematics was tested with a robotic-universal force sensor testing system under 2 loading conditions. An 89-N anterior load was applied, and an anterior tibial translation was measured at knee flexion angles of 0°, 30°, 60°, and 90°. Then, combined rotatory loads of 7-N·m valgus and 5-N·m internal tibial rotation were applied at 15° and 30° of knee flexion angles, which mimic the pivot shift. Afterward, only the AM bundle of the ACL was cut arthroscopically, keeping the posterolateral bundle intact. The knee was again tested using the intact knee kinematics to measure the in situ force of the AM bundle. Then, arthroscopic anatomic AM bundle reconstruction was performed with an allograft, and the knee was tested to give the in situ force of the reconstructed AM bundle. Knee kinematics under the 3 conditions (intact, anatomic AM augmentation, and nonanatomic high AM augmentation) and the in situ force were compared and analyzed. The high AM graft had significantly lower in situ force than the intact and anatomic reconstructed AM bundle at 0° of knee flexion (P < .05) and the intact AM bundle at 30° of knee flexion under anterior tibial loading. There were no differences between anatomic graft and intact AM bundle. The high AM graft also had a significantly lower in situ force than the intact and anatomic reconstructed AM with simulated pivot-shift loading at 15° and 30° of flexion (P < .05). Under anterior tibial and rotatory loading, there was a difference in tibial displacement between anatomic and high AM reconstructions and between the high AM graft and intact ACL under rotational loading with the knee at 15° of flexion. Anatomic AM augmentation can lead to biomechanical advantages at time zero when compared with the nonanatomic (high AM) augmentation. Anatomic AM augmentation better restores the knee kinematics to the intact ACL state.
Human torque velocity adaptations to sprint, endurance, or combined modes of training
NASA Technical Reports Server (NTRS)
Shealy, M. J.; Callister, R.; Dudley, G. A.; Fleck, S. J.
1992-01-01
We had groups of athletes perform sprint and endurance run training independently or concurrently for 8 weeks to examine the voluntary in vivo mechanical responses to each type of training. Pre- and posttraining angle-specific peak torque during knee extension and flexion were determined at 0, 0.84, 1.65, 2.51, 3.35, 4.19, and 5.03 radian.sec-1 and normalized for lean body mass. Knee extension torque in the sprint-trained group increased across all test velocities, the endurance-trained group increased at 2.51, 3.34, 4.19, and 5.03 radian.sec-1, and the group performing the combined training showed no change at any velocity. Knee flexion torque of the sprint and combined groups decreased at 0.84, 1.65, and 2.51 radian.sec-1. Knee flexion torque in the sprint-trained group also decreased at 0 radian.sec-1 and in the combined group at 3.34 radian.sec-1. Knee flexion torque in the endurance-trained group showed no change at any velocity of contraction. Mean knee flexion:extension ratios across the test velocities significantly decreased in the sprint-trained group. Knee extension endurance during 30 seconds of maximal contractions significantly increased in all groups. Only the sprint-trained group showed a significant increase in endurance of the knee flexors. These data suggest that changes in the voluntary in vivo mechanical characteristics of knee extensor and flexor skeletal muscles are specific to the type of run training performed.
Tateuchi, Hiroshige; Taniguchi, Masashi; Takagi, Yui; Goto, Yusuke; Otsuka, Naoki; Koyama, Yumiko; Kobayashi, Masashi; Ichihashi, Noriaki
2014-01-01
Footwear modification can beneficially alter knee loading in patients with knee osteoarthritis. This study evaluated the effect of Masai Barefoot Technology shoes on reductions in external knee moments in patients with knee osteoarthritis. Three-dimensional motion analysis was used to examine the effect of Masai Barefoot Technology versus control shoes on the knee adduction and flexion moments in 17 women (mean age, 63.6 years) with radiographically confirmed knee osteoarthritis. The lateral and anterior trunk lean values, knee flexion and adduction angles, and ground reaction force were also evaluated. The influence of the original walking pattern on the changes in knee moments with Masai Barefoot Technology shoes was evaluated. The knee flexion moment in early stance was significantly reduced while walking with the Masai Barefoot Technology shoes (0.25±0.14Nm/kgm) as compared with walking with control shoes (0.30±0.19 Nm/kgm); whereas the knee adduction moment showed no changes. Masai Barefoot Technology shoes did not increase compensatory lateral and anterior trunk lean. The degree of knee flexion moment in the original walking pattern with control shoes was correlated directly with its reduction when wearing Masai Barefoot Technology shoes by multiple linear regression analysis (adjusted R2=0.44, P<0.01). Masai Barefoot Technology shoes reduced the knee flexion moment during walking without increasing the compensatory trunk lean and may therefore reduce external knee loading in women with knee osteoarthritis. Copyright © 2014 Elsevier B.V. All rights reserved.
Wünschel, Markus; Wülker, Nikolaus; Müller, Otto
2013-11-01
Females have a higher risk in terms of anterior cruciate ligament injuries during sports than males. Reasons for this fact may be different anatomy and muscle recruitment patterns leading to less protection for the cruciate- and collateral-ligaments. This in vitro study aims to evaluate gender differences in knee joint kinematics and muscle force during weight-bearing knee flexions. Thirty-four human knee specimens (17 females/17 males) were mounted on a dynamic knee simulator. Weight-bearing single-leg knee flexions were performed with different amounts of simulated body weight (BW). Gender-specific kinematics was measured with an ultrasonic motion capture system and different loading conditions were examined. Knee joint kinematics did not show significant differences regarding anteroposterior and medial-lateral movement as well as tibial varus-valgus and internal-external rotation. This applied to all simulated amounts of BW. Simulating 100 N BW in contrast to AF50 led to a significant higher quadriceps overall force in female knees from 45° to 85° of flexion in contrast to BW 50 N. In these female specimens, the quadriceps overall force was about 20 % higher than in male knees being constant in higher flexion angles. It is indicated by our results that in a squatting movement females compared with males produce higher muscle forces, suggesting an increased demand for muscular stabilization, whereas tibio-femoral kinematics was similar for both genders.
Pfile, Kate R.; Hart, Joseph M.; Herman, Daniel C.; Hertel, Jay; Kerrigan, D. Casey; Ingersoll, Christopher D.
2013-01-01
Context: Anterior cruciate ligament (ACL) injuries are common in female athletes and are related to poor neuromuscular control. Comprehensive neuromuscular training has been shown to improve biomechanics; however, we do not know which component of neuromuscular training is most responsible for the changes. Objective: To assess the efficacy of either a 4-week core stability program or plyometric program in altering lower extremity and trunk biomechanics during a drop vertical jump (DVJ). Design: Cohort study. Setting: High school athletic fields and motion analysis laboratory. Patients or Other Participants: Twenty-three high school female athletes (age = 14.8 ± 0.8 years, height = 1.7 ± 0.07 m, mass = 57.7 ± 8.5 kg). Intervention(s): Independent variables were group (core stability, plyometric, control) and time (pretest, posttest). Participants performed 5 DVJs at pretest and posttest. Intervention participants engaged in a 4-week core stability or plyometric program. Main Outcome Measure(s): Dependent variables were 3-dimensional hip, knee, and trunk kinetics and kinematics during the landing phase of a DVJ. We calculated the group means and associated 95% confidence intervals for the first 25% of landing. Cohen d effect sizes with 95% confidence intervals were calculated for all differences. Results: We found within-group differences for lower extremity biomechanics for both intervention groups (P ≤ .05). The plyometric group decreased the knee-flexion and knee internal-rotation angles and the knee-flexion and knee-abduction moments. The core stability group decreased the knee-flexion and knee internal-rotation angles and the hip-flexion and hip internal-rotation moments. The control group decreased the knee external-rotation moment. All kinetic changes had a strong effect size (Cohen d > 0.80). Conclusions: Both programs resulted in biomechanical changes, suggesting that both types of exercises are warranted for ACL injury prevention and should be implemented by trained professionals. PMID:23768121
Đorđević, Srđan; Tomažič, Sašo; Narici, Marco; Pišot, Rado; Meglič, Andrej
2014-01-01
Skeletal muscle is the largest tissue structure in our body and plays an essential role for producing motion through integrated action with bones, tendons, ligaments and joints, for stabilizing body position, for generation of heat through cell respiration and for blood glucose disposal. A key function of skeletal muscle is force generation. Non-invasive and selective measurement of muscle contraction force in the field and in clinical settings has always been challenging. The aim of our work has been to develop a sensor that can overcome these difficulties and therefore enable measurement of muscle force during different contraction conditions. In this study, we tested the mechanical properties of a “Muscle Contraction” (MC) sensor during isometric muscle contraction in different length/tension conditions. The MC sensor is attached so that it indents the skin overlying a muscle group and detects varying degrees of tension during muscular contraction. We compared MC sensor readings over the biceps brachii (BB) muscle to dynamometric measurements of force of elbow flexion, together with recordings of surface EMG signal of BB during isometric contractions at 15° and 90° of elbow flexion. Statistical correlation between MC signal and force was very high at 15° (r = 0.976) and 90° (r = 0.966) across the complete time domain. Normalized SD or σN = σ/max(FMC) was used as a measure of linearity of MC signal and elbow flexion force in dynamic conditions. The average was 8.24% for an elbow angle of 90° and 10.01% for an elbow of angle 15°, which indicates high linearity and good dynamic properties of MC sensor signal when compared to elbow flexion force. The next step of testing MC sensor potential will be to measure tension of muscle-tendon complex in conditions when length and tension change simultaneously during human motion. PMID:25256114
Đorđević, Srđan; Tomažič, Sašo; Narici, Marco; Pišot, Rado; Meglič, Andrej
2014-09-25
Skeletal muscle is the largest tissue structure in our body and plays an essential role for producing motion through integrated action with bones, tendons, ligaments and joints, for stabilizing body position, for generation of heat through cell respiration and for blood glucose disposal. A key function of skeletal muscle is force generation. Non-invasive and selective measurement of muscle contraction force in the field and in clinical settings has always been challenging. The aim of our work has been to develop a sensor that can overcome these difficulties and therefore enable measurement of muscle force during different contraction conditions. In this study, we tested the mechanical properties of a "Muscle Contraction" (MC) sensor during isometric muscle contraction in different length/tension conditions. The MC sensor is attached so that it indents the skin overlying a muscle group and detects varying degrees of tension during muscular contraction. We compared MC sensor readings over the biceps brachii (BB) muscle to dynamometric measurements of force of elbow flexion, together with recordings of surface EMG signal of BB during isometric contractions at 15° and 90° of elbow flexion. Statistical correlation between MC signal and force was very high at 15° (r = 0.976) and 90° (r = 0.966) across the complete time domain. Normalized SD or σN = σ/max(FMC) was used as a measure of linearity of MC signal and elbow flexion force in dynamic conditions. The average was 8.24% for an elbow angle of 90° and 10.01% for an elbow of angle 15°, which indicates high linearity and good dynamic properties of MC sensor signal when compared to elbow flexion force. The next step of testing MC sensor potential will be to measure tension of muscle-tendon complex in conditions when length and tension change simultaneously during human motion.
Is passive stiffness in human muscles related to the elasticity of tendon structures?
Kubo, K; Kanehisa, H; Fukunaga, T
2001-08-01
The purpose of this study was to examine in vivo whether passive stiffness in human muscles was related to the elasticity of tendon structures and to performance during stretch-shortening cycle exercise. Passive torque of plantar flexor muscles was measured during passive stretch from 90 degrees (anatomical position) to 65 degrees of dorsiflexion at a constant velocity of 5 degrees.s-1. The slope of the linear portion of the passive torque-angle curve during stretching was defined as the passive stiffness of the muscle. The elongation of the tendon and aponeurosis of the medial gastrocnemius muscle (MG) was directly measured using ultrasonography during ramp isometric plantar flexion up to the voluntary maximum. The relationship between the estimated muscle force of MG and tendon elongation was fitted to a linear regression, the slope of which was defined as the stiffness of the tendon. In addition, the dynamic torques during maximal voluntary concentric plantar flexion with and without prior eccentric contraction were determined at a constant velocity of 120 degrees.s-1. There were no significant correlations between passive stiffness and either the tendon stiffness (r = 0.19, P > 0.05) or the relative increase in torque with prior eccentric contraction (r = -0.19, P > 0.05). However, tendon stiffness was negatively correlated to the relative increase in torque output (r = -0.42, P < 0.05). The present results suggested that passive stiffness was independent of the elasticity of tendon structures, and had no favourable effect on the muscle performance during stretch-shortening cycle exercise.
Designs and performance of microprocessor-controlled knee joints.
Thiele, Julius; Westebbe, Bettina; Bellmann, Malte; Kraft, Marc
2014-02-01
In this comparative study, three transfemoral amputee subjects were fitted with four different microprocessor-controlled exoprosthetic knee joints (MPK): C-Leg, Orion, Plié2.0, and Rel-K. In a motion analysis laboratory, objective gait measures were acquired during level walking at different velocities. Subsequent technical analyses, which involved X-ray computed tomography, identified the functional mechanisms of each device and enabled corroboration of the performance in the gait laboratory by the engineering design of the MPK. Gait measures showed that the mean increase of the maximum knee flexion angle at different walking velocities was closest in value to the unaffected contralateral knee (6.2°/m/s) with C-Leg (3.5°/m/s; Rel-K 17.0°/m/s, Orion 18.3°/m/s, and Plié2.0 28.1°/m/s). Technical analyses corroborated that only with Plié2.0 the flexion resistances were not regulated by microprocessor control at different walking velocities. The muscular effort for the initiation of the swing phase, measured by the minimum hip moment, was found to be lowest with C-Leg (-82.1±14.1 Nm; Rel-K -83.59±17.8 Nm, Orion -88.0±16.3 Nm, and Plié2.0 -91.6±16.5 Nm). Reaching the extension stop at the end of swing phase was reliably executed with both Plié2.0 and C-Leg. Abrupt terminal stance phase extension observed with Plié2.0 and Rel-K could be attributed to the absence of microprocessor control of extension resistance.
Oyama, Sakiko; Waldhelm, Andrew G; Sosa, Araceli R; Patel, Ravina R; Kalinowski, Derick L
2017-09-01
Pitching technique is one of many factors that affect injury risk. Exhibiting excessive contralateral trunk tilt (CLT) during pitching has been linked to higher ball speed but also to increased joint loading. Deficit in trunk muscle strength has been suggested as an underlying cause of this movement pattern. The purpose of the study was to compare trunk muscle strength between youth baseball pitchers with varying degree of CLT during pitching. Cross-sectional study. Baseball practice fields. Twenty-eight youth baseball pitchers. Pitching technique was captured using a video camera. Based on the 2-dimensional trunk contralateral flexion angle, pitchers were categorized into low (<15 degrees), moderate (15-30 degrees), or high (>30 degrees) CLT groups. Maximum isometric strength tests for trunk flexion, extension, and bilateral rotation, measured using a dynamometer. The pitchers with high CLT (n = 10) had longer pitching experience (P = 0.014), produced higher ball speed (P = 0.003) compared with the pitchers with moderate (n = 10) and low (n = 8) CLT, but demonstrated greater asymmetry in trunk rotation strength (relative weakness in rotation strength toward dominant side) compared with the pitchers with low CLT (P = 0.015). Excessive CLT may be a strategy that young pitchers learn to achieve higher ball velocity but also may be associated with imbalance between the oblique muscles on dominant and nondominant side, which may be acquired from repetitive pitching. Strengthening and emphasizing the use of dominant side oblique muscles may keep pitchers from leaning excessively during pitching and thus decrease joint loading.
Knee biomechanics during a jump-cut maneuver: Effects of gender & ACL surgery
Miranda, Daniel L.; Fadale, Paul D.; Hulstyn, Michael J.; Shalvoy, Robert M.; Machan, Jason T.; Fleming, Braden C.
2012-01-01
Purpose The purpose of this study was to compare kinetic and knee kinematic measurements from male and female ACL-intact (ACLINT) and ACL-reconstructed (ACLREC) subjects during a jump-cut maneuver using biplanar videoradiography. Methods Twenty subjects were recruited; 10 ACLINT (5 males, 5 females) and 10 ACLREC (4 males, 6 females; five years post surgery). Each subject performed a jump-cut maneuver by landing on a single leg and performing a 45° side-step cut. Ground reaction force was measured by a force plate and expressed relative to body weight. Six-degree-of-freedom knee kinematics were determined from a biplanar videoradiography system and an optical motion capture system. Results ACLINT female subjects landed with a larger peak vertical GRF (p<0.001) compared to ACLINT male subjects. ACLINT subjects landed with a larger peak vertical GRF (p≤0.036) compared to ACLREC subjects. Regardless of ACL reconstruction status, female subjects underwent less knee flexion angle excursion (p=0.002) and had an increased average rate of anterior tibial translation (0.05±0.01%/millisecond; p=0.037) after contact compared to male subjects. Furthermore, ACLREC subjects had a lower rate of anterior tibial translation compared to ACLINT subjects (0.05±0.01%/millisecond; p=0.035). Finally, no striking differences were observed in other knee motion parameters. Conclusion Women permit a smaller amount of knee flexion angle excursion during a jump-cut maneuver, resulting in a larger peak vertical GRF and increased rate of anterior tibial translation. Notably, ACLREC subjects also perform the jump cut maneuver with lower GRF than ACLINT subjects five years post surgery. This study proposes a causal sequence whereby increased landing stiffness (larger peak vertical GRF combined with less knee flexion angle excursion) leads to an increased rate of anterior tibial translation while performing a jump-cut maneuver. PMID:23190595
Electromyographic assessment of apple bucket intervention designed to reduce back strain.
Earle-Richardson, Giulia; Jenkins, Paul L; Strogatz, David; Bell, Erin M; Freivalds, Andris; Sorensen, Julie A; May, John J
2008-06-01
The authors previously developed an apple bucket that was modified by use of a hip belt to reduce muscle fatigue. The intervention of belt use was accepted by workers and shown not to interfere with productivity. However, use of this intervention did not appear to reduce muscle fatigue when measured by tests of voluntary muscle strength. The purpose of the present study was to evaluate the intervention's effect on muscle fatigue employing surface electromyographic (EMG) amplitude. Amplitude measurements on 15 muscles were taken from 10 laboratory volunteers who were carrying a full bucket of apples, once while wearing the intervention belt and once without the intervention. These measurements were taken for seven different postures (four angles of trunk flexion (0 degrees , 20 degrees , 45 degrees , 90 degrees ) and three raised-arm positions (both up, dominant up, non-dominant up)) common to apple harvest work. Participants were measured in these conditions both with the bucket carried in front and with the bucket carried to the side. Significant reductions in amplitude favouring the intervention were seen for 11 of the 15 muscles in models considering the four body flexion angles. Ten of these were of the middle and lower back. These control/intervention differences were seen with both bucket-carrying positions (front vs. side) and tended to increase with increasing flexion angle. In contrast, no significant intervention effects were observed in models considering treatment by arm-raised position. One significant main effect (upper trapezius, side bucket) showed an amplitude reduction in the treatment condition. Another main effect showing increased amplitude in the intervention condition use was observed in the dominant levator scapulae (side bucket). Thus, the use of the intervention belt reduces EMG amplitude among a number of mid- and lower-back muscles. This is suggestive of a protective effect against back strain.
Camara, Camila Thais Pinto; de Freitas, Sandra Maria Sbeghen Ferreira; de Lima, Waléria Paixão; Lima, Camila Astolphi; Amorim, César Ferreira; Perracini, Monica Rodrigues
2017-01-01
Our aim is to estimate inter-observer reliability, test-retest reliability, anthropometric and biomechanical adequacy and minimal detectable change when measuring the length of single-point adjustable canes in community-dwelling older adults. There are 112 participants in the study. They are men and women, aged 60 years and over, who were attending an outpatient community health centre. An exploratory study design was used. Participants underwent two assessments within the same day by two independent observers and by the same observer at an interval of 15-45 days. Two measures were used to establish the length of a single-point adjustable cane: the distance from the distal wrist crease to the floor (WF) and the distance from the top of the greater trochanter of the femur to the floor (TF). Each individual was fitted according to these two measures, and elbow flexion angle was measured. Inter-observer reliability and the test-retest reliability were high in both TF (ICC 3.1 = 0.918 and ICC 2.1 = 0.935) and WF measures (ICC 3.1 = 0.967 and ICC 2.1 = 0.960). Only 1% of the individuals kept an elbow flexion angle within the standard recommendation of 30° ± 10° when the cane length was determined by the TF measure, and 30% of the participants when the cane was determined by the WF measure. The minimal detectable cane length change was 2.2 cm. Our results suggest that, even though both measures are reliable, cane length determined by WF distance is more appropriate to keep the elbow flexion angle within the standard recommendation. The minimal detectable change corresponds to approximately a hole in the cane adjustment. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Celebrini, Richard G.; Eng, Janice J.; Miller, William C.; Ekegren, Christina L.; Johnston, James D.; Depew, Thomas A.; MacIntyre, Donna L.
2015-01-01
Objective To determine the effect of a novel movement strategy incorporated within a soccer warm-up on biomechanical risk factors for ACL injury during three sport-specific movement tasks. Design Single-blind, randomized controlled clinical trial. Setting Laboratory setting. Participants 20 top-tier female teenage soccer players. Interventions Subjects were randomized to the Core Position and Control movement strategy (Core-PAC) warm-up or standard warm-up which took place prior to their regular soccer practice over a 6-week period. The Core-PAC focuses on getting the centre of mass closer to the plant foot or base of support. Main Outcome Measures Peak knee flexion angle and abduction moments during a side-hop (SH), side-cut (SC) and unanticipated side-cut (USC) task after the 6-weeks with (intervention group only) and without a reminder to use the Core-PAC strategy. Results The Core-PAC group increased peak flexion angles during the SH task (Mean difference = 6.2°, 95% CI: 1.9–10.5°, effect size = 1.01, P = 0.034) after the 6-week warm-up program without a reminder. In addition, the Core-PAC group demonstrated increased knee flexion angles for the side-cut (Mean difference = 8.5°, 95% CI: 4.8–12.2°, ES = 2.02, P = 0.001) and side-hop (Mean difference = 10.0°, 95% CI: 5.7–14.3°, ES = 1.66, P = 0.001) task after a reminder. No changes in abduction moments were found. Conclusions The results of this study suggest that the Core-PAC may be one method of modifying high-risk soccer-specific movements and can be implemented within a practical, team-based soccer warm-up. The results should be interpreted with caution due to the small sample size. PMID:24184850
Reliability and Validity of Nonradiologic Measures of Forward Flexed Posture in Parkinson Disease.
Nair, Prajakta; Bohannon, Richard W; Devaney, Laurie; Maloney, Catherine; Romano, Alexis
2017-03-01
To examine the intertester reliability and validity of 5 nonradiologic measures of forward flexed posture in individuals with Parkinson disease (PD). Cross-sectional observational study. University outpatient facility and community centers. Individuals (N=28) with PD with Hoehn and Yahr scores of 1 through 4. Not applicable. Occiput to wall status, tragus to wall distance, C7 to wall distance, photographically derived trunk flexion angle, and inclinometric kyphosis measure. Participants were older adults (mean, 69.7±10.6y) with a 14-month to 15-year (mean, 5.9±3.5y) history of PD. Intertester reliability was excellent for all measures (κ=.89 [cued condition] and 1.0 [relaxed condition] for occiput to wall status; intraclass correlation coefficients, .779-.897 for tragus to wall distance, C7 to wall distance, flexion angle, and inclinometric kyphosis measure). Convergent validity was supported for all measures by significant correlations between the same measures obtained during relaxed and cued conditions (eg, occiput to wall relaxed and cued) and for most measures by significant correlations between measures obtained under the same condition (eg, occiput to wall cued and tragus to wall cued). Significant correlations between tragus to wall distance, C7 to wall distance, flexion angle, and inclinometric kyphosis measure and the Unified Parkinson Disease Rating Scale item 28 (posture) also supported convergent validity. Significant differences between tragus to wall distance, C7 to wall distance, and inclinometric kyphosis measure values under relaxed and cued conditions supported known condition validity. Known group validity was demonstrated by significant differences in tragus to wall distance, C7 to wall distance, and inclinometric kyphosis measure obtained from individuals able and individuals unable to touch their occiput to wall when cued to stand tall. Tragus to wall distance, C7 to wall distance, and inclinometric kyphosis measure are reliable and valid nonradiologic measures of forward flexed posture in PD. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Mechanisms of ACL injury in professional rugby union: a systematic video analysis of 36 cases.
Montgomery, Connor; Blackburn, Jeff; Withers, Daniel; Tierney, Gregory; Moran, Cathal; Simms, Ciaran
2016-12-30
The mechanisms of ACL injury in rugby are not well defined. To describe the mechanisms of ACL injury in male professional rugby players using systematic video analysis. 36 cases from games played in top professional leagues and international matches were analysed. 5 analysts independently assessed all videos to record the estimated frame/time of initial ground contact, frame/time of ACL tear and a range of play specific variables. This included contact versus non-contact ACL injuries, injury timing, joint flexion angles and foot contact with the ground. 37 side-stepping manoeuvres from a control game were analysed to allow comparison of non-injury versus injury situations. 57% of ACL injuries occurred in a contact manner. 2 main scenarios were identified: (1) offensive running and (2) being tackled, indicating that the ball carrier might be at higher risk of ACL injury. The majority of non-contact ACL injuries resulted from a side-stepping manoeuvre. In most non-contact cases, initial ground contact was through heel strike. Statistical assessment of heel strike at initial ground contact versus non-heel strike cases showed a significant difference in injury versus non-injury outcomes, with heel strike associated with higher injury risk. Non-contact ACL injuries had lower median knee flexion angles and a more dorsiflexed ankle when compared with a control group (10° vs 20°, p≤0.001 and 10° vs 0°, p=0.033 respectively). Over half of ACL injuries in rugby in our analysis resulted from a contact mechanism. For non-contact injuries, lower knee flexion angles and heel-first ground contact in a side-stepping manoeuvre were associated with ACL injury. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Lauber, Benedikt; Lichtwark, Glen A; Cresswell, Andrew G
2014-06-01
While medial gastrocnemius (MG) and soleus (SOL) are considered synergists, they are anatomically exclusive in that SOL crosses only the ankle, while MG crosses both the knee and ankle. Due to the force-length properties of both active and passive structures, activation of SOL and MG must be constantly regulated to provide the required joint torques for any planned movement. As such, the aim of this study was to investigate the neural regulation of MG and SOL when independently changing their length by changing only the knee joint angle, thus exclusively altering the length of MG fibers. MG and SOL motor units (MU) were recorded intramuscularly along with ultrasound imaging of MG and SOL fascicle lengths, while moving the knee through 60° of rotation and maintaining a low level of voluntary plantar flexor torque. The results showed a reciprocal activation of MG and SOL as the knee was moved into flexion and extension. A clear reduction in MG MU firing rates occurred as the knee was flexed (MG fascicles shortening), with de-recruitment of most MG MU occurring at close to full knee flexion. A concomitant increase in SOL MU activity was observed while no change in the length of its fascicles was found. The opposite effects were found when the knee was moved into extension. A strong correlation (ICC = 0.78) was found between the fascicle length at which MG MUs were de-recruited and subsequently re-recruited. This was stronger than the relationship of de-recruitment and re-recruitment with knee angle (ICC = 0.52), indicating that in this instance, muscle fascicle length rather than joint angle is more influential in regulating MG recruitment. Such a reciprocal arrangement like the one presented here for SOL and MG is essential for human voluntary movements such as walking or cycling. © 2014 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.
Nakamura, Shinichiro; Tanaka, Yoshihisa; Kuriyama, Shinichi; Nishitani, Kohei; Ito, Hiromu; Furu, Moritoshi; Matsuda, Shuichi
2017-06-01
Anterior knee pain has been reported as a major postoperative complication after total knee arthroplasty, which may lead to patient dissatisfaction. Rotational alignment and the medial-lateral position correlate with patellar maltracking, which can cause knee pain postoperatively. However, the superior-inferior position of the patellar component has not been investigated. The purpose of the current study was to investigate the effects of the patellar superior-inferior position on patellofemoral kinematics and kinetics. Superior, central, and inferior models with a dome patellar component were constructed. In the superior and inferior models, the position of the patellar component translated superiorly and inferiorly, respectively, by 3mm, relative to the center model. Kinematics of the patellar component, quadriceps force, and patellofemoral contact force were calculated using a computer simulation during a squatting activity in a weight-bearing deep knee bend. In the inferior model, the flexion angle, relative to the tibial component, was the greatest among all models. The inferior model showed an 18.0%, 36.5%, and 22.7% increase in the maximum quadriceps force, the maximum medial patellofemoral force, and the maximum lateral patellofemoral force, respectively, compared with the superior model. Superior-inferior positions affected patellofemoral kinematic and kinetics. Surgeons should avoid the inferior position of the patellar component, because the inferior positioned model showed greater quadriceps and patellofemoral force, resulting in a potential risk for anterior knee pain and component loosening. Copyright © 2017. Published by Elsevier Ltd.
Liao, Tzu-Chieh; Keyak, Joyce H; Powers, Christopher M
2018-02-27
The purpose of this study is to determine whether recreational runners with patellofemoral pain (PFP) exhibit greater peak patella cartilage stress compared to pain-free runners. A secondary purpose was to determine the kinematic and/or kinetic predictors of peak patella cartilage stress during running. Twenty-two female recreational runners participated (12 with PFP and 10 pain-free controls). Patella cartilage stress profiles were quantified using subject-specific finite element models simulating the maximum knee flexion angle during stance phase of running. Input parameters to the finite element model included subject-specific patellofemoral joint geometry, quadriceps muscle forces, and lower extremity kinematics in the frontal and transverse planes. Tibiofemoral joint kinematics and kinetics were quantified to determine the best predictor of stress using stepwise regression analysis. Compared to the pain-free runners, those with PFP exhibited greater peak hydrostatic pressure (PFP vs. control, 21.2 ± 5.6 MPa vs. 16.5 ± 4.6 MPa) and maximum shear stress (11.3 ± 4.6 MPa vs. 8.7 ± 2.3 MPa). Knee external rotation was the best predictor of peak hydrostatic pressure and peak maximum shear stress (38% and 25% of variances, respectively) followed by the knee extensor moment (21% and 25% of variances, respectively). Runners with PFP exhibit greater peak patella cartilage stress during running compared to pain-free individuals. The combination of knee external rotation and a high knee extensor moment best predicted elevated peak stress during running.
Aguiar, Liliana; Santos-Rocha, Rita; Vieira, Filomena; Branco, Marco; Andrade, Carlos; Veloso, António
2015-10-01
The assessment of biomechanical loading in the musculoskeletal system of the pregnant women is particularly interesting since they are subject to morphological, physiological and hormonal changes, which may lead to adaptations in gait. The purpose of this study was to analyze the effect of the increased mass in the trunk associated to pregnancy on the lower limb and pelvis, during walking, on temporal-distance parameters, joint range of motion and moments of force, by comparing a pregnant women group to a non-pregnant group, and to this group while carrying a 5 kg additional load located in the abdomen and breasts during walking, to understand which gait adaptations may be more related with the increased trunk mass, or if may be more associated with other factors such as the girth of the thigh. The subjects performed a previous 12 min training adaption to the added load. To calculate ankle, knee and hip joint angles and moments of force, a three-dimensional biomechanical model was developed. The inverse dynamics method was used to estimate net joint moments of force. The increased mass of the anterior trunk associated with second trimester of pregnancy may influence some gait variables such as the left step time, left and right stance times, double limb support time, maximum hip extension, maximum pelvic right obliquity, pelvic obliquity range of motion, maximum transversal left rotation and peak hip flexion moments of force. Copyright © 2015 Elsevier B.V. All rights reserved.
Kobayashi, Toshiki; Arabian, Adam K.; Orendurff, Michael S.; Rosenbaum-Chou, Teri G.; Boone, David A.
2014-01-01
Background Energy storage and return feet are designed for active amputees. However, little is known about the socket reaction moments in transtibial prostheses with energy storage and return feet. The aim of this study was to investigate the effect of alignment changes on the socket reaction moments during gait while using the energy storage and return feet. Methods A Smart Pyramid™ was used to measure the socket reaction moments in 10 subjects with transtibial prostheses while walking under 25 alignment conditions, including a nominal alignment (as defined by conventional clinical methods), as well as angle malalignments of 2°, 4° and 6° (flexion, extension, abduction, and adduction) and translation malalignments of 5mm, 10mm and 15mm (anterior, posterior, lateral, and medial) referenced from the nominal alignment. The socket reaction moments of the nominal alignment were compared with each malalignment. Findings Both coronal and sagittal alignment changes demonstrated systematic effects on the socket reaction moments. In the sagittal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the minimum moment, the moment at 45% of stance and the maximum moment for some comparisons. In the coronal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the moment at 30% and 75% of stance for all comparisons. Interpretation The alignment may have systematic effects on the socket reaction moments in transtibial prostheses with energy storage and return feet. The socket reaction moments could potentially be a useful biomechanical parameter to evaluate the alignment of the transtibial prostheses. PMID:24315709
Gatt, Alfred; Chockalingam, Nachiappan
2012-06-01
Trials investigating ankle joint measurement normally apply a known moment. Maximum ankle angle is affected by foot posture and stretching characteristics of the calf muscles. To investigate whether consistent maximum ankle angles could be achieved without applying a constant moment to all subjects, and whether short, repetitive stretching of the calf muscle tendon unit would produce a difference in the maximum ankle angle. Passive dorsiflexion in 14 healthy participants was captured using an optoelectronic motion analysis system, with the foot placed in 3 postures. The maximum ankle angles for both the neutral and supinated positions did not differ significantly. In general, the majority of subjects (92.8%) showed no increase in the maximum ankle dorsiflexion angle following repetitive brief passive stretching. Only one subject exhibited a significant increase in maximum ankle angle at the neutral position. Since the range of motion of the ankle joint is clearly determined by other physical factors, the maximum ankle dorsiflexion angle can be assessed at both neutral and supinated positions without moment being controlled. Copyright © 2011 Elsevier Ltd. All rights reserved.
Do changes in neuromuscular activation contribute to the knee extensor angle-torque relationship?
Lanza, Marcel B; Balshaw, Thomas G; Folland, Jonathan P
2017-08-01
What is the central question of the study? Do changes in neuromuscular activation contribute to the knee extensor angle-torque relationship? What is the main finding and its importance? Both agonist (quadriceps) and antagonist coactivation (hamstrings) differed with knee joint angle during maximal isometric knee extensions and thus both are likely to contribute to the angle-torque relationship. Specifically, two independent measurement techniques showed quadriceps activation to be lower at more extended positions. These effects might influence the capacity for neural changes in response to training and rehabilitation at different knee joint angles. The influence of joint angle on knee extensor neuromuscular activation is unclear, owing in part to the diversity of surface electromyography (sEMG) and/or interpolated twitch technique (ITT) methods used. The aim of the study was to compare neuromuscular activation, using rigorous contemporary sEMG and ITT procedures, during isometric maximal voluntary contractions (iMVCs) of the quadriceps femoris at different knee joint angles and examine whether activation contributes to the angle-torque relationship. Sixteen healthy active men completed two familiarization sessions and two experimental sessions of isometric knee extension and knee flexion contractions. The experimental sessions included the following at each of four joint angles (25, 50, 80 and 106 deg): iMVCs (with and without superimposed evoked doublets); submaximal contractions with superimposed doublets; and evoked twitch and doublet contractions whilst voluntarily passive, and knee flexion iMVC at the same knee joint positions. The absolute quadriceps femoris EMG was normalized to the peak-to-peak amplitude of an evoked maximal M-wave, and the doublet-voluntary torque relationship was used to calculate activation with the ITT. Agonist activation, assessed with both normalized EMG and the ITT, was reduced at the more extended compared with the more flexed positions (25 and 50 versus 80 and 106 deg; P ≤ 0.016), whereas antagonist coactivation was greatest in the most flexed compared with the extended positions (106 versus 25 and 50 deg; P ≤ 0.02). In conclusion, both agonist and antagonist activation differed with knee joint angle during knee extension iMVCs, and thus both are likely to contribute to the knee extensor angle-torque relationship. © 2017 The Authors. Experimental Physiology © 2017 The Physiological Society.
Brown, Scott R; Wang, Henry; Dickin, D Clark; Weiss, Kaitlyn J
2014-11-01
This study examined the relationship between leg preference and knee mechanics in females during sidestepping. Three-dimensional data were recorded on 16 female collegiate footballers during a planned 45° sidestep manoeuvre with their preferred and non-preferred kicking leg. Knee kinematics and kinetics during initial contact, weight acceptance, peak push-off, and final push-off phases of sidestepping were analysed in both legs. The preferred leg showed trivial to small increases (ES = 0.19-0.36) in knee flexion angle at initial contact, weight acceptance, and peak push-off, and small increases (ES = 0.21-0.34) in peak power production and peak knee extension velocity. The non-preferred leg showed a trivial increase (ES = 0.10) in knee abduction angle during weight acceptance; small to moderate increases (ES = 0.22-0.64) in knee internal rotation angle at weight acceptance, peak push-off, and final push-off; a small increase (ES = 0.22) in knee abductor moment; and trivial increases (ES = 0.09-0.14) in peak power absorption and peak knee flexion velocity. The results of this study show that differences do exist between the preferred and non-preferred leg in females. The findings of this study will increase the knowledge base of anterior cruciate ligament injury in females and can aid in the design of more appropriate neuromuscular, plyometric, and strength training protocols for injury prevention.
Effects of neck exercise on high-school students' neck-shoulder posture.
Lee, Myoung-Hyo; Park, Su-Jin; Kim, Jin-Sang
2013-05-01
[Purpose] This study examined the effects of deep flexor muscle-strengthening exercise on the neck-shoulder posture, and the strength and endurance of the deep flexor muscles of high-school students. [Subjects] The subjects were 30 seventeen-year-old female high-school students who complained about bad posture and chronic neck-shoulder pain. They were randomly divided into an experimental group of 15 subjects, who performed a deep flexor muscle-strengthening exercise and a control group of 15 subjects, who performed a basic stretching exercise. [Methods] The experimental group of 15 subjects performed a deep flexor muscle-strengthening exercise consisting of low-load training of the cranio-cervical flexor muscle, and the control group of 15 subjects performed a basic stretching exercise consisting of seven motions. [Results] The experimental group showed statistically significant changes in head tilt angle, neck flexion angle, forward shoulder angle, and the result of the cranio-cervical flexion test after the training. In contrast, the control group showed no statistically significant changes in these measures following the training. When the results of the groups were compared, statistically significant differences were found for all items between the experimental group and the control group. [Conclusion] Strengthening cranio-cervical flexor muscles is important for the adjustment of neck posture, and maintaining their stability is required to improve neck-shoulder posture.
Dataglove measurement of joint angles in sign language handshapes
Eccarius, Petra; Bour, Rebecca; Scheidt, Robert A.
2012-01-01
In sign language research, we understand little about articulatory factors involved in shaping phonemic boundaries or the amount (and articulatory nature) of acceptable phonetic variation between handshapes. To date, there exists no comprehensive analysis of handshape based on the quantitative measurement of joint angles during sign production. The purpose of our work is to develop a methodology for collecting and visualizing quantitative handshape data in an attempt to better understand how handshapes are produced at a phonetic level. In this pursuit, we seek to quantify the flexion and abduction angles of the finger joints using a commercial data glove (CyberGlove; Immersion Inc.). We present calibration procedures used to convert raw glove signals into joint angles. We then implement those procedures and evaluate their ability to accurately predict joint angle. Finally, we provide examples of how our recording techniques might inform current research questions. PMID:23997644
Gordon, Brian J; Dapena, Jesús
2013-01-04
Inaccuracy in determining the orientation of the upper arm about its longitudinal axis (twist orientation) has been a pervasive problem in sport biomechanics research. The purpose of this study was to develop a method to improve the calculation of the upper arm twist orientation in dynamic sports activities. The twist orientation of the upper arm is defined by the orientation of its mediolateral axis. The basis for the new method is that at any angle in the flexion/extension range of an individual's elbow, it is possible to define a true mediolateral axis and also a surrogate mediolateral axis perpendicular to the plane containing the shoulder, elbow and wrist joints. The difference between the twist orientations indicated by these two versions of the mediolateral axis will vary from one elbow angle to another, but if the elbow joint deforms equally in different activities, for any given subject the difference should be constant at any given value of the elbow angle. Application of the new method required individuals to execute sedate elbow extension trials prior to the dynamic trials. Three-dimensional motion analysis of the sedate extension trials allowed quantification of the difference between the true and surrogate mediolateral axes for all angles in the entire flexion/extension range of an individual's elbow. This made it possible to calculate in any dynamic trial the twist orientation defined by the true mediolateral axis from the twist orientation defined by the surrogate mediolateral axis. The method was tested on a wooden model of the arm. Copyright © 2012 Elsevier Ltd. All rights reserved.
Toumi, A; Leteneur, S; Gillet, C; Debril, J-F; Decoufour, N; Barbier, F; Jakobi, J M; Simoneau-Buessinger, Emilie
2015-11-01
Many studies have focused on maximum torque exerted by ankle joint muscles during plantar flexion. While strength parameters are typically measured with isokinetic or isolated ankle dynamometers, these devices often present substantial limitations for the measurement of torque because they account for force in only 1 dimension (1D), and the device often constrains the body in a position that augments torque through counter movements. The purposes of this study were to determine the contribution of body position to ankle plantar-flexion torque and to assess the use of 1D and 3D torque sensors. A custom designed 'Booted, Open-Unit, Three dimension, Transportable, Ergometer' (B.O.T.T.E.) was used to quantify plantar flexion in two conditions: (1) when the participant was restrained within the unit (locked-unit) and (2) when the participant's position was independent of the ankle dynamometer (open-unit). Ten young males performed maximal voluntary isometric plantar-flexion contractions using the B.O.T.T.E. in open and locked-unit mechanical configurations. The B.O.T.T.E. was reliable with ICC higher than 0.90, and CV lower than 7 %. The plantar-flexion maximal resultant torque was significantly higher in the locked-unit compared with open-unit configuration (P < 0.001; +61 to +157 %) due to the addition of forces from the body being constrained within the testing device. A 1D compared with 3D torque sensor significantly underestimated the proper capacity of plantar-flexion torque production (P < 0.001; -37 to -60 %). Assessment of plantar-flexion torque should be performed with an open-unit dynamometer mounted with a 3D sensor that is exclusive of accessory muscles but inclusive of all ankle joint movements.
Koh, Jason L; Yi, Seung Jin; Ren, Yupeng; Zimmerman, Todd A; Zhang, Li-Qun
2016-11-02
The meniscus is known to increase the contact area and decrease contact pressure in the tibiofemoral compartments of the knee. Radial tears of the meniscal root attachment along with partial resections of the torn meniscal tissue decrease the contact area and increase pressure; however, there is a lack of information on the effects of a horizontal cleavage tear (HCT) and partial leaf meniscectomy of such tears on tibiofemoral contact pressure and contact area. Twelve fresh-frozen human cadaveric knees were tested under 10 conditions: 5 serial conditions of posterior medial meniscectomy (intact meniscus, HCT, repaired HCT, inferior leaf resection, and resection of both inferior and superior leaves), each at 2 knee flexion angles (0° and 60°) under an 800-N axial load. Tekscan sensors (model 4000) were used to measure the contact pressure and contact area. HCT and HCT repair resulted in small changes in the contact area and an increase in contact pressure compared with the intact condition. Resection of the inferior leaf resulted in significantly decreased contact area (to a mean 82.3% of the intact condition at 0° of flexion and 81.8% at 60° of flexion; p < 0.05) and increased peak contact pressure (a mean 36.3% increase at 0° flexion and 43.2% increase at 60° flexion; p < 0.05) in the medial compartment. Further resection of the remaining superior leaf resulted in additional significant decreases in contact area (to a mean 60.1% of the intact condition at 0° of flexion and 49.7% at 60° of flexion; p < 0.05) and increases in peak contact pressure (a mean 79.2% increase at 0° of flexion and 74.9% increase at 60° of flexion; p < 0.05). Resection of meniscal tissue forming the inferior leaf of an HCT resulted in substantially decreased contact area and increased contact pressure. Additional resection of the superior leaf resulted in a further significant decrease in contact area and increase in contact pressure in the medial compartment. Repair or minimal resection of meniscal tissue of an HCT may be preferred to complete leaf resection to maintain knee tibiofemoral contact mechanics. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.
Gokeler, Alli; Bisschop, Marsha; Myer, Gregory D; Benjaminse, Anne; Dijkstra, Pieter U; van Keeken, Helco G; van Raay, Jos J A M; Burgerhof, Johannes G M; Otten, Egbert
2016-07-01
The purpose of this study was to evaluate the influence of immersion in a virtual reality environment on knee biomechanics in patients after ACL reconstruction (ACLR). It was hypothesized that virtual reality techniques aimed to change attentional focus would influence altered knee flexion angle, knee extension moment and peak vertical ground reaction force (vGRF) in patients following ACLR. Twenty athletes following ACLR and 20 healthy controls (CTRL) performed a step-down task in both a non-virtual reality environment and a virtual reality environment displaying a pedestrian traffic scene. A motion analysis system and force plates were used to measure kinematics and kinetics during a step-down task to analyse each single-leg landing. A significant main effect was found for environment for knee flexion excursion (P = n.s.). Significant interaction differences were found between environment and groups for vGRF (P = 0.004), knee moment (P < 0.001), knee angle at peak vGRF (P = 0.01) and knee flexion excursion (P = 0.03). There was larger effect of virtual reality environment on knee biomechanics in patients after ACLR compared with controls. Patients after ACLR immersed in virtual reality environment demonstrated knee joint biomechanics that approximate those of CTRL. The results of this study indicate that a realistic virtual reality scenario may distract patients after ACLR from conscious motor control. Application of clinically available technology may aid in current rehabilitation programmes to target altered movement patterns after ACLR. Diagnostic study, Level III.
Harding, Graeme T; Hubley-Kozey, Cheryl L; Dunbar, Michael J; Stanish, William D; Astephen Wilson, Janie L
2012-11-01
Obesity is a highly cited risk factor for knee osteoarthritis (OA), but its role in knee OA pathogenesis and progression is not as clear. Excess weight may contribute to an increased mechanical burden and altered dynamic movement and loading patterns at the knee. The objective of this study was to examine the interacting role of moderate knee OA disease presence and obesity on knee joint mechanics during gait. Gait analysis was performed on 104 asymptomatic and 140 individuals with moderate knee OA. Each subject group was divided into three body mass categories based on body mass index (BMI): healthy weight (BMI<25), overweight (25≤BMI≤30), and obese (BMI>30). Three-dimensional knee joint angles and net external knee joint moments were calculated and waveform principal component analysis (PCA) was applied to extract major patterns of variability from each. PC scores for major patterns were compared between groups using a two-factor ANOVA. Significant BMI main effects were found in the pattern of the knee adduction moment, the knee flexion moment, and the knee rotation moment during gait. Two interaction effects between moderate OA disease presence and BMI were also found that described different changes in the knee flexion moment and the knee flexion angle with increased BMI with and without knee OA. Our results suggest that increased BMI is associated with different changes in biomechanical patterns of the knee joint during gait depending on the presence of moderate knee OA. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Estimation of distal arm joint angles from EMG and shoulder orientation for transhumeral prostheses.
Akhtar, Aadeel; Aghasadeghi, Navid; Hargrove, Levi; Bretl, Timothy
2017-08-01
In this paper, we quantify the extent to which shoulder orientation, upper-arm electromyography (EMG), and forearm EMG are predictors of distal arm joint angles during reaching in eight subjects without disability as well as three subjects with a unilateral transhumeral amputation and targeted reinnervation. Prior studies have shown that shoulder orientation and upper-arm EMG, taken separately, are predictors of both elbow flexion/extension and forearm pronation/supination. We show that, for eight subjects without disability, shoulder orientation and upper-arm EMG together are a significantly better predictor of both elbow flexion/extension during unilateral (R 2 =0.72) and mirrored bilateral (R 2 =0.72) reaches and of forearm pronation/supination during unilateral (R 2 =0.77) and mirrored bilateral (R 2 =0.70) reaches. We also show that adding forearm EMG further improves the prediction of forearm pronation/supination during unilateral (R 2 =0.82) and mirrored bilateral (R 2 =0.75) reaches. In principle, these results provide the basis for choosing inputs for control of transhumeral prostheses, both by subjects with targeted motor reinnervation (when forearm EMG is available) and by subjects without target motor reinnervation (when forearm EMG is not available). In particular, we confirm that shoulder orientation and upper-arm EMG together best predict elbow flexion/extension (R 2 =0.72) for three subjects with unilateral transhumeral amputations and targeted motor reinnervation. However, shoulder orientation alone best predicts forearm pronation/supination (R 2 =0.88) for these subjects, a contradictory result that merits further study. Copyright © 2017 Elsevier Ltd. All rights reserved.
Viscoelastic Response of the Human Lower Back to Passive Flexion: The Effects of Age.
Shojaei, Iman; Allen-Bryant, Kacy; Bazrgari, Babak
2016-09-01
Low back pain is a leading cause of disability in the elderly. The potential role of spinal instability in increasing risk of low back pain with aging was indirectly investigated via assessment of age-related differences in viscoelastic response of lower back to passive deformation. The passive deformation tests were conducted in upright standing posture to account for the effects of gravity load and corresponding internal tissues responses on the lower back viscoelastic response. Average bending stiffness, viscoelastic relaxation, and dissipated energy were quantified to characterize viscoelastic response of the lower back. Larger average bending stiffness, viscoelastic relaxation and dissipated energy were observed among older vs. younger participants. Furthermore, average bending stiffness of the lower back was found to be the highest around the neutral standing posture and to decrease with increasing the lower back flexion angle. Larger bending stiffness of the lower back at flexion angles where passive contribution of lower back tissues to its bending stiffness was minimal (i.e., around neutral standing posture) highlighted the important role of active vs. passive contribution of tissues to lower back bending stiffness and spinal stability. As a whole our results suggested that a diminishing contribution of passive and volitional active subsystems to spinal stability may not be a reason for higher severity of low back pain in older population. The role of other contributing elements to spinal stability (e.g., active reflexive) as well as equilibrium-based parameters (e.g., compression and shear forces under various activities) in increasing severity of low back pain with aging should be investigated in future.
Hoch, Matthew C.; Farwell, Kelley E.; Gaven, Stacey L.; Weinhandl, Joshua T.
2015-01-01
Context People with chronic ankle instability (CAI) exhibit less weight-bearing dorsiflexion range of motion (ROM) and less knee flexion during landing than people with stable ankles. Examining the relationship between dorsiflexion ROM and landing biomechanics may identify a modifiable factor associated with altered kinematics and kinetics during landing tasks. Objective To examine the relationship between weight-bearing dorsiflexion ROM and single-legged landing biomechanics in persons with CAI. Design Cross-sectional study. Setting Laboratory. Patients or Other Participants Fifteen physically active persons with CAI (5 men, 10 women; age = 21.9 ± 2.1 years, height = 168.7 ± 9.0 cm, mass = 69.4 ± 13.3 kg) participated. Intervention(s) Participants performed dorsiflexion ROM and single-legged landings from a 40-cm height. Sagittal-plane kinematics of the lower extremity and ground reaction forces (GRFs) were captured during landing. Main Outcome Measure(s) Static dorsiflexion was measured using the weight-bearing–lunge test. Kinematics of the ankle, knee, and hip were observed at initial contact, maximum angle, and sagittal displacement. Sagittal displacements of the ankle, knee, and hip were summed to examine overall sagittal displacement. Kinetic variables were maximum posterior and vertical GRFs normalized to body weight. We used Pearson product moment correlations to evaluate the relationships between dorsiflexion ROM and landing biomechanics. Correlations (r) were interpreted as weak (0.00–0.40), moderate (0.41–0.69), or strong (0.70–1.00). The coefficient of determination (r2) was used to determine the amount of explained variance among variables. Results Static dorsiflexion ROM was moderately correlated with maximum dorsiflexion (r = 0.49, r2 = 0.24), ankle displacement (r = 0.47, r2 = 0.22), and total displacement (r = 0.67, r2 = 0.45) during landing. Dorsiflexion ROM measured statically and during landing demonstrated moderate to strong correlations with maximum knee (r = 0.69–0.74, r2 = 0.47–0.55) and hip (r = 0.50–0.64, r2 = 0.25–0.40) flexion, hip (r = 0.53–0.55, r2 = 0.28–0.30) and knee (r = 0.53–0.70, r2 = 0.28–0.49) displacement, and vertical GRF (−0.47– −0.50, r2 = 0.22–0.25). Conclusions Dorsiflexion ROM was moderately to strongly related to sagittal-plane kinematics and maximum vertical GRF during single-legged landing in persons with CAI. Persons with less dorsiflexion ROM demonstrated a more erect landing posture and greater GRF. PMID:26067428
Kim, Stanley E; Pozzi, Antonio; Banks, Scott A; Conrad, Bryan P; Lewis, Daniel D
2010-04-01
To assess contact mechanics and 3-dimensional (3-D) joint alignment in cranial cruciate ligament (CCL)-deficient stifles before and after tibial plateau leveling osteotomy (TPLO) and tibial tuberosity advancement (TTA) with the stifle in 90 degrees of flexion. In vitro biomechanical study. Cadaveric pelvic limb pairs (n=8) from dogs weighing 28-35 kg. Contralateral limbs were assigned to receive TPLO or TTA. Digital pressure sensors were used to measure femorotibial contact area, peak and mean contact pressure, and peak pressure location with the limb under a load of 30% body weight and stifle flexion angle of 90 degrees . 3-D poses were obtained using a Microscribe digitizer. Specimens were tested under normal, CCL deficient, and treatment conditions. Significant disturbances in alignment were not observed after CCL transection, although medial contact area was 10% smaller than normal (P=.003). There were no significant differences in contact mechanics or alignment between normal and TTA conditions; TPLO induced 6 degrees varus angulation (P<.001), 26% decrease in lateral peak pressure (P=.027), and 18% increase in medial mean pressure (P=.008) when compared with normal. Cranial tibial subluxation is nominal in CCL-deficient stifles loaded in flexion. Stifle alignment and contact mechanics are not altered by TTA, whereas TPLO causes mild varus and a subsequent increase in medial compartment loading. Cranial tibial subluxation of CCL-deficient stifles may not occur during postures that load the stifle in flexion. The significance of minor changes in loading patterns after TPLO is unknown.
Hey, Hwee Weng Dennis; Lau, Eugene Tze-Chun; Tan, Kimberly-Anne; Lim, Joel L; Choong, Denise; Lau, Leok-Lim; Liu, Ka-Po G; Wong, Hee-Kit
2017-10-01
A cross-sectional study of prospectively collected data. To compare lumbar spine alignment in six common postures, and estimate loss in range of motion (ROM) relative to standing. Ideal position for fusion of lumbar spine remains unknown. Although surgical fusion is necessary for deformity correction and symptom relief, the final position in which the vertebrae are immobilized should provide maximum residual function. Data were collected prospectively from 70 patients with low back pain recruited over a year. All subjects had x-rays performed in slump sitting, forward bending, supine, half squatting, standing, and backward bending postures. ROM quantified in terms of sagittal global and segmental Cobb angles was measured from L1 to S1. Loss of ROM relative to standing was calculated for each posture. Analysis of variance and unpaired t tests were used to identify differences in alignment between postures. Slump sitting gives the greatest lumbar flexion followed by forward bending, and supine postures (P < 0.001). Backward bending produces greater lumbar extension than standing (P = 0.035). Half-squatting and standing postures were not significantly different (P = 0.938). For all postures, L4-5 and L5-S1 segments remained in lordosis, with L4-5 having greater ROM than L5-S1. L1-2 turns kyphotic in lying supine, L2-3 at forward bending, and L3-4 at slump sitting in the form of a "kyphosing cascade." Should the entire lumbar spine be fused in standing position from L1-S1, there would likely be a mean loss of 47.6° of lumbar flexion and 5.9° of lumbar extension. The present study demonstrates the extent of flexibility required of the lumbar spine in assuming various postures. It also enables comparison of the differences in degree of motion occurring in the lumbar spine, both across postures and across segments. Significant loss in ROM, particularly flexion, is anticipated with fusion modeled after the lordotic standing lumbar spine. 2.
Levine, Iris C; Minty, Lauren E; Laing, Andrew C
2015-03-01
Fall-related hip injuries are a concern for the growing population of older adults. Evidence suggests that soft tissue overlying the greater trochanter attenuates the forces transmitted to the proximal femur during an impact, reducing mechanical risk of hip fracture. However, there is limited information about the factors that influence trochanteric soft tissue thickness. The current study used ultrasonography and electromyography to determine whether trochanteric soft tissue thickness could be quantified reproducibly and whether it was influenced by: (1) gender; (2) hip postures associated with potential falling configurations in the sagittal plane (from 30° of extension to 60° of flexion, at 15° intervals), combined adduction-flexion, and combined adduction-extension; and (3) activation levels of the tensor fascia lata (TFL) and gluteus medius (GM) muscles. Our results demonstrated that soft tissue thickness can be measured reliably in nine hip postures and three muscle activation conditions (for all conditions, ICC >0.98). Mean (SD) thickness in quiet stance was 2.52 cm. Thickness was 27.0% lower for males than females during quiet stance. It was 16.4% greater at maximum flexion than quiet standing, 27.2% greater at maximum extension, and 12.5% greater during combined adduction-flexion. However, there was no significant difference between combined adduction-extension and quiet standing. Thickness was not affected by changes in muscle activity. Forces applied to the femoral neck during a lateral fall decrease as trochanteric soft tissue thickness increases; gender and postural configuration at impact could influence the loads applied to the proximal femur (and thus hip fracture risk) during falls on the hip. © 2014 Wiley Periodicals, Inc.
sEMG feature evaluation for identification of elbow angle resolution in graded arm movement.
Castro, Maria Claudia F; Colombini, Esther L; Aquino, Plinio T; Arjunan, Sridhar P; Kumar, Dinesh K
2014-11-25
Automatic and accurate identification of elbow angle from surface electromyogram (sEMG) is essential for myoelectric controlled upper limb exoskeleton systems. This requires appropriate selection of sEMG features, and identifying the limitations of such a system.This study has demonstrated that it is possible to identify three discrete positions of the elbow; full extension, right angle, and mid-way point, with window size of only 200 milliseconds. It was seen that while most features were suitable for this purpose, Power Spectral Density Averages (PSD-Av) performed best. The system correctly classified the sEMG against the elbow angle for 100% cases when only two discrete positions (full extension and elbow at right angle) were considered, while correct classification was 89% when there were three discrete positions. However, sEMG was unable to accurately determine the elbow position when five discrete angles were considered. It was also observed that there was no difference for extension or flexion phases.