NASA Astrophysics Data System (ADS)
Houmat, A.
2018-02-01
The optimal lay-up design for the maximum fundamental frequency of variable stiffness laminated composite plates is investigated using a layer-wise optimization technique. The design variables are two fibre orientation angles per ply. Thin plate theory is used in conjunction with a p-element to calculate the fundamental frequencies of symmetrically and antisymmetrically laminated composite plates. Comparisons with existing optimal solutions for constant stiffness symmetrically laminated composite plates show excellent agreement. It is observed that the maximum fundamental frequency can be increased considerably using variable stiffness design as compared to constant stiffness design. In addition, optimal lay-ups for the maximum fundamental frequency of variable stiffness symmetrically and antisymmetrically laminated composite plates with different aspect ratios and various combinations of free, simply supported and clamped edge conditions are presented. These should prove a useful benchmark for optimal lay-ups of variable stiffness laminated composite plates.
Second-harmonic generation of a dual-frequency laser in a MgO:PPLN crystal.
Kang, Ying; Yang, Suhui; Brunel, Marc; Cheng, Lijun; Zhao, Changming; Zhang, Haiyang
2017-04-10
A dual-frequency CW laser at a wavelength of 1.064 μm is frequency doubled in a MgO:PPLN nonlinear crystal. The fundamental dual-frequency laser has a tunable beat note from 125 MHz to 175 MHz. A laser-diode pumped fiber amplifier is used to amplify the dual-frequency fundamental output to a maximum power of 50 W before frequency doubling. The maximum output power of the green light is 1.75 W when the input fundamental power is 12 W, corresponding to a frequency doubling efficiency of 14.6%. After frequency doubling, green light with modulation frequencies in two bands from 125 MHz to 175 MHz and from 250 MHz to 350 MHz is achieved simultaneously. The relative intensities of the beat notes at the two bands can be adjusted by changing the relative intensities at different frequencies of the fundamental light. The spectral width and frequency stabilities of the beat notes in fundamental wave and green light are also measured, respectively. The modulated green light has potential applications in underwater ranging, communication, and imaging.
Shao, Xu; Milner, Ben
2005-08-01
This work proposes a method to reconstruct an acoustic speech signal solely from a stream of mel-frequency cepstral coefficients (MFCCs) as may be encountered in a distributed speech recognition (DSR) system. Previous methods for speech reconstruction have required, in addition to the MFCC vectors, fundamental frequency and voicing components. In this work the voicing classification and fundamental frequency are predicted from the MFCC vectors themselves using two maximum a posteriori (MAP) methods. The first method enables fundamental frequency prediction by modeling the joint density of MFCCs and fundamental frequency using a single Gaussian mixture model (GMM). The second scheme uses a set of hidden Markov models (HMMs) to link together a set of state-dependent GMMs, which enables a more localized modeling of the joint density of MFCCs and fundamental frequency. Experimental results on speaker-independent male and female speech show that accurate voicing classification and fundamental frequency prediction is attained when compared to hand-corrected reference fundamental frequency measurements. The use of the predicted fundamental frequency and voicing for speech reconstruction is shown to give very similar speech quality to that obtained using the reference fundamental frequency and voicing.
Schultz-Coulon, H J
1975-07-01
The applicability of a newly developed fundamental frequency analyzer to diagnosis in phoniatrics is reviewed. During routine voice examination, the analyzer allows a quick and accurate measurement of fundamental frequency and sound level of the speaking voice, and of vocal range and maximum phonation time. By computing fundamental frequency histograms, the median fundamental frequency and the total pitch range can be better determined and compared. Objective studies of certain technical faculties of the singing voice, which usually are estimated subjectively by the speech therapist, may now be done by means of this analyzer. Several examples demonstrate the differences between correct and incorrect phonation. These studies compare the pitch perturbations during the crescendo and decrescendo of a swell-tone, and show typical traces of staccato, thrill and yodel. Conclusions of the study indicate that fundamental frequency analysis is a valuable supplemental method for objective voice examination.
Neck Circumference and Vocal Parameters in Women Before and After Bariatric Surgery.
de Souza, Lourdes Bernadete Rocha; Pernambuco, Leandro de Araújo; dos Santos, Marquiony Marques; Pereira, Rayane Medeiros
2016-03-01
Morbidly obese patients may suffer from vocal disorders, as vocal production is directly related to the volume of the vocal tract, and the large-scale accumulation of fat in this region may interfere with voice production. The aim of this study was to analyze the neck circumference, fundamental frequency, and maximum phonation time of a group of morbidly obese women before and after bariatric surgery. An observational, longitudinal, and descriptive study was performed with patients of the Obesity and Related Diseases Surgery Unit of a university hospital. A total of 21 morbidly obese women aged 28-68 years, with a mean age of 41.33 years, participated in the study. Neck circumference was measured using a tape measure. To obtain fundamental frequency values, the patient was asked to produce the vowel [a] at normal intensity and pitch for an average period of 3 s. After recording, the participants were asked to produce the sustained vowels [a], [i], and [u] at normal intensity and pitch, with a stopwatch used to measure maximum phonation time. Eight months after surgery, patients were reassessed using the same data collecting procedures as were carried out prior to surgery. After surgery, there was an increase in the average value of fundamental frequency and maximum phonation time for all the vowels and a reduction in neck circumference. The differences were statistically significant. Weight reduction and a consequent decrease in neck circumference affected the changes in maximum phonation time and fundamental frequency values in the voices of these patients, after weight loss.
A frequency doubled pressure-tunable oscillator-amplifier dye laser system
NASA Technical Reports Server (NTRS)
Moriarty, A.; Heaps, W.; Davis, D. D.
1976-01-01
A tunable high-repetition-rate oscillator-amplifier dye-laser system is reported. The dye laser described was longitudinally pumped with the second harmonic of a Nd-YAG laser operating at 10 Hz. Using three Faraday-Perot etalons and pressure tuning, a maximum fundamental output power of the order of 6 MW with a corresponding spectral width of less than 0.003 nm at 564 nm was obtained. The fundamental at 564 nm was frequency doubled to give a maximum power level of 0.6 MW of second-harmonic output power with a spectral width less than 0.0015 nm at 282 nm. Frequency stability could be maintained to within approximately 15% of the line-width.
Fundamental frequency, phonation maximum time and vocal complaints in morbidly obese women
de SOUZA, Lourdes Bernadete Rocha; PEREIRA, Rayane Medeiros; dos SANTOS, Marquiony Marques; GODOY, Cynthia Meida de Almeida
2014-01-01
Background Obese people have abnormal deposition of fat in the vocal tract that can interfere with the acoustic voice. Aim To relate the fundamental frequency, the maximum phonation time and voice complaints from a group of morbidly obese women. Methods Observational, cross-sectional and descriptive study that included 44 morbidly obese women, mean age of 42.45 (±10.31) years old, observational group and 30 women without obesity, control group, with 33.79 (±4.51)years old. The voice recording was done in a quiet environment, on a laptop using the program ANAGRAF acoustic analysis of speech sounds. To extract the values of fundamental frequency the subjects were asked to produce vowel [a] at usual intensity for a period in average of three seconds. After the voice recording, participants were prompted to produce sustained vowel [ a] , [ i] and [ u] at usual intensity and height, using a stopwatch to measure the time that each participant could hold each vowel. Results The majority, 31(70.5%), had vocal complaints, with a higher percentage for complaints of vocal fatigue 20(64.51%) and voice failures 19(61.29%) followed by dryness of the throat in 15 (48.38%) and effort to speak 13(41.93%). There was no statistically significant difference regarding the mean fundamental frequency of the voice in both groups, but there was significance between the two groups regarding maximum phonation. Conclusion Increased adipose tissue in the vocal tract interfered in the vocal parameters. PMID:24676298
High-frequency harmonic imaging of the eye.
Silverman, Ronald H; Coleman, D Jackson; Ketterling, Jeffrey A; Lizzi, Frederic L
2005-01-01
PURPOSE: Harmonic imaging has become a well-established technique for ultrasonic imaging at fundamental frequencies of 10 MHz or less. Ophthalmology has benefited from the use of fundamentals of 20 MHz to 50 MHz. Our aim was to explore the ability to generate harmonics for this frequency range, and to generate harmonic images of the eye. METHODS: The presence of harmonics was determined in both water and bovine vitreous propagation media by pulse/echo and hydrophone at a series of increasing excitation pulse intensities and frequencies. Hydrophone measurements were made at the focal point and in the near- and far-fields of 20 MHz and 40 MHz transducers. Harmonic images of the anterior segment of the rabbit eye were obtained by a combination of analog filtering and digital post-processing. RESULTS: Harmonics were generated nearly identically in both water and vitreous. Hydrophone measurements showed the maximum second harmonic to be -5 dB relative to the 35 MHz fundamental at the focus, while in pulse/echo the maximum harmonic amplitude was -15dB relative to the fundamental. Harmonics were absent in the near-field, but present in the far-field. Harmonic images of the eye showed improved resolution. CONCLUSION: Harmonics can be readily generated at very high frequencies, and at power levels compliant with FDA guidelines for ophthalmology. This technique may yield further improvements to the already impressive resolutions obtainable in this frequency range. Improved imaging of the macular region, in particular, may provide significant improvements in diagnosis of retinal disease.
High-frequency harmonic imaging of the eye
NASA Astrophysics Data System (ADS)
Silverman, Ronald H.; Coleman, D. Jackson; Ketterling, Jeffrey A.; Lizzi, Frederic L.
2005-04-01
Purpose: Harmonic imaging has become a well-established technique for ultrasonic imaging at fundamental frequencies of 10 MHz or less. Ophthalmology has benefited from the use of fundamentals of 20 MHz to 50 MHz. Our aim was to explore the ability to generate harmonics for this frequency range, and to generate harmonic images of the eye. Methods: The presence of harmonics was determined in both water and bovine vitreous propagation media by pulse/echo and hydrophone at a series of increasing excitation pulse intensities and frequencies. Hydrophone measurements were made at the focal point and in the near- and far-fields of 20 MHz and 40 MHz transducers. Harmonic images of the anterior segment of the rabbit eye were obtained by a combination of analog filtering and digital post-processing. Results: Harmonics were generated nearly identically in both water and vitreous. Hydrophone measurements showed the maximum second harmonic to be -5 dB relative to the 35 MHz fundamental at the focus, while in pulse/echo the maximum harmonic amplitude was -15dB relative to the fundamental. Harmonics were absent in the near-field, but present in the far-field. Harmonic images of the eye showed improved resolution. Conclusion: Harmonics can be readily generated at very high frequencies, and at power levels compliant with FDA guidelines for ophthalmology. This technique may yield further improvements to the already impressive resolutions obtainable in this frequency range. Improved imaging of the macular region, in particular, may provide significant improvements in diagnosis of retinal disease.
Voice characteristics in the progression of Parkinson's disease.
Holmes, R J; Oates, J M; Phyland, D J; Hughes, A J
2000-01-01
This study examined the acoustic and perceptual voice characteristics of patients with Parkinson's disease according to disease severity. The perceptual and acoustic voice characteristics of 30 patients with early stage PD and 30 patients with later stage PD were compared with data from 30 normal control subjects. Voice recordings consisted of prolongation of the vowel /a/, scale singing, and a 1-min monologue. In comparison with controls and previously published normative data, both early and later stage PD patients' voices were characterized perceptually by limited pitch and loudness variability, breathiness, harshness and reduced loudness. High modal pitch levels also characterized the voices of males in both early and later stages of PD. Acoustically, the voices of both groups of PD patients demonstrated lower mean intensity levels and reduced maximum phonational frequency ranges in comparison with normative data. Although less clear, the present data also suggested that the PD patients' voices were characterized by excess jitter, a high-speaking fundamental frequency for males and a reduced fundamental frequency variability for females. While several of these voice features did not appear to deteriorate with disease progression (i.e. harshness, high modal pitch and speaking fundamental frequency in males, fundamental frequency variability in females, low intensity and jitter), breathiness, monopitch and monoloudness, low loudness and reduced maximum phonational frequency range were all worse in the later stages of PD. Tremor was the sole voice feature which was associated only with later stage PD.
Polycrystalline diamond RF MOSFET with MoO3 gate dielectric
NASA Astrophysics Data System (ADS)
Ren, Zeyang; Zhang, Jinfeng; Zhang, Jincheng; Zhang, Chunfu; Chen, Dazheng; Quan, Rudai; Yang, Jiayin; Lin, Zhiyu; Hao, Yue
2017-12-01
We report the radio frequency characteristics of the diamond metal-oxide-semiconductor field effect transistor with MoO3 gate dielectric for the first time. The device with 2-μm gate length was fabricated on high quality polycrystalline diamond. The maximum drain current of 150 mA/mm at VGS = -5 V and the maximum transconductance of 27 mS/mm were achieved. The extrinsic cutoff frequency of 1.2 GHz and the maximum oscillation frequency of 1.9 GHz have been measured. The moderate frequency characteristics are attributed to the moderate transconductance limited by the series resistance along the channel. We expect that the frequency characteristics of the device can be improved by increasing the magnitude of gm, or fundamentally decreasing the gate-controlled channel resistance and series resistance along the channel, and down-scaling the gate length.
Body mass index and acoustic voice parameters: is there a relationship.
Souza, Lourdes Bernadete Rocha de; Santos, Marquiony Marques Dos
2017-05-06
Specific elements such as weight and body volume can interfere in voice production and consequently in its acoustic parameters, which is why it is important for the clinician to be aware of these relationships. To investigate the relationship between body mass index and the average acoustic voice parameters. Observational, cross-sectional descriptive study. The sample consisted of 84 women, aged between 18 and 40years, an average of 26.83 (±6.88). The subjects were grouped according to body mass index: 19 underweight; 23 normal ranges, 20 overweight and 22 obese and evaluated the fundamental frequency of the sustained vowel [a] and the maximum phonation time of the vowels [a], [i], [u], using PRAAT software. The data were submitted to the Kruskal-Wallis test to verify if there were differences between the groups regarding the study variables. All variables showed statistically significant results and were subjected to non-parametric test Mann-Whitney. Regarding to the average of the fundamental frequency, there was statistically significant difference between groups with underweight and overweight and obese; normal range and overweight and obese. The average maximum phonation time revealed statistically significant difference between underweight and obese individuals; normal range and obese; overweight and obese. Body mass index influenced the average fundamental frequency of overweight and obese individuals evaluated in this study. Obesity influenced in reducing maximum phonation time average. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Vocal warm-up increases phonation threshold pressure in soprano singers at high pitch.
Motel, Tamara; Fisher, Kimberly V; Leydon, Ciara
2003-06-01
Vocal warm-up is thought to optimize singing performance. We compared effects of short-term, submaximal, vocal warm-up exercise with those of vocal rest on the soprano voice (n = 10, ages 19-21 years). Dependent variables were the minimum subglottic air pressure required for vocal fold oscillation to occur (phonation threshold pressure, Pth), and the maximum and minimum phonation fundamental frequency. Warm-up increased Pth for high pitch phonation (p = 0.033), but not for comfortable (p = 0.297) or low (p = 0.087) pitch phonation. No significant difference in the maximum phonation frequency (p = 0.193) or minimum frequency (p = 0.222) was observed. An elevated Pth at controlled high pitch, but an unchanging maximum and minimum frequency production suggests that short-term vocal exercise may increase the viscosity of the vocal fold and thus serve to stabilize the high voice.
Presence of strong harmonics during visual entrainment: a magnetoencephalography study.
Heinrichs-Graham, Elizabeth; Wilson, Tony W
2012-09-01
Visual neurons are known to synchronize their firing with stimuli that flicker at a constant rate (e.g. 12Hz). These so-called visual steady-state responses (VSSR) are a well-studied phenomenon, yet the underlying mechanisms are widely disagreed upon. Furthermore, there is limited evidence that visual neurons may simultaneously synchronize at harmonics of the stimulation frequency. We utilized magnetoencephalography (MEG) to examine synchronization at harmonics of the visual stimulation frequency (18Hz). MEG data were analyzed for event-related-synchronization (ERS) at the fundamental frequency, 36, 54, and 72Hz. We found strong ERS in all bands. Only 31% of participants showed maximum entrainment at the fundamental; others showed stronger entrainment at either 36 or 54Hz. The cortical foci of these responses indicated that the harmonics involved cortices that were partially distinct from the fundamental. These findings suggest that spatially-overlapping subpopulations of neurons are simultaneously entrained at different harmonics of the stimulus frequency. Copyright © 2012 Elsevier B.V. All rights reserved.
Disc piezoelectric ceramic transformers.
Erhart, Jirií; Půlpán, Petr; Doleček, Roman; Psota, Pavel; Lédl, Vít
2013-08-01
In this contribution, we present our study on disc-shaped and homogeneously poled piezoelectric ceramic transformers working in planar-extensional vibration modes. Transformers are designed with electrodes divided into wedge, axisymmetrical ring-dot, moonie, smile, or yin-yang segments. Transformation ratio, efficiency, and input and output impedances were measured for low-power signals. Transformer efficiency and transformation ratio were measured as a function of frequency and impedance load in the secondary circuit. Optimum impedance for the maximum efficiency has been found. Maximum efficiency and no-load transformation ratio can reach almost 100% and 52 for the fundamental resonance of ring-dot transformers and 98% and 67 for the second resonance of 2-segment wedge transformers. Maximum efficiency was reached at optimum impedance, which is in the range from 500 Ω to 10 kΩ, depending on the electrode pattern and size. Fundamental vibration mode and its overtones were further studied using frequency-modulated digital holographic interferometry and by the finite element method. Complementary information has been obtained by the infrared camera visualization of surface temperature profiles at higher driving power.
Riede, Tobias; Tokuda, Isao T.; Farmer, C. G.
2011-01-01
SUMMARY Vocalization is rare among non-avian reptiles, with the exception of the crocodilians, the sister taxon of birds. Crocodilians have a complex vocal repertoire. Their vocal and respiratory system is not well understood but appears to consist of a combination of features that are also found in the extremely vocal avian and mammalian taxa. Anatomical studies suggest that the alligator larynx is able to abduct and adduct the vocal folds, but not to elongate or shorten them, and is therefore lacking a key regulator of frequency, yet alligators can modulate fundamental frequency remarkably well. We investigated the morphological and physiological features of sound production in alligators. Vocal fold length scales isometrically across a wide range of alligator body sizes. The relationship between fundamental frequency and subglottal pressure is significant in some individuals at some isolated points, such as call onset and position of maximum fundamental frequency. The relationship is not consistent over large segments of the call. Fundamental frequency can change faster than expected by pressure changes alone, suggesting an active motor pattern controls frequency and is intrinsic to the larynx. We utilized a two-mass vocal fold model to test whether abduction and adduction could generate this motor pattern. The fine-tuned interplay between subglottal pressure and glottal adduction can achieve frequency modulations much larger than those resulting from subglottal pressure variations alone and of similar magnitude, as observed in alligator calls. We conclude that the alligator larynx represents a sound source with only two control parameters (subglottal pressure and vocal fold adduction) in contrast to the mammalian larynx in which three parameters can be altered to modulate frequency (subglottal pressure, vocal fold adduction and length/tension). PMID:21865521
NASA Astrophysics Data System (ADS)
Encomendero, Jimy; Yan, Rusen; Verma, Amit; Islam, S. M.; Protasenko, Vladimir; Rouvimov, Sergei; Fay, Patrick; Jena, Debdeep; Xing, Huili Grace
2018-03-01
We report the generation of room temperature microwave oscillations from GaN/AlN resonant tunneling diodes, which exhibit record-high peak current densities. The tunneling heterostructure grown by molecular beam epitaxy on freestanding GaN substrates comprises a thin GaN quantum well embedded between two AlN tunneling barriers. The room temperature current-voltage characteristics exhibit a record-high maximum peak current density of ˜220 kA/cm2. When biased within the negative differential conductance region, microwave oscillations are measured with a fundamental frequency of ˜0.94 GHz, generating an output power of ˜3.0 μW. Both the fundamental frequency and the output power of the oscillator are limited by the external biasing circuit. Using a small-signal equivalent circuit model, the maximum intrinsic frequency of oscillation for these diodes is predicted to be ˜200 GHz. This work represents a significant step towards microwave power generation enabled by resonant tunneling transport, an ultra-fast process that goes beyond the limitations of current III-Nitride high electron mobility transistors.
The effect of recording and analysis bandwidth on acoustic identification of delphinid species.
Oswald, Julie N; Rankin, Shannon; Barlow, Jay
2004-11-01
Because many cetacean species produce characteristic calls that propagate well under water, acoustic techniques can be used to detect and identify them. The ability to identify cetaceans to species using acoustic methods varies and may be affected by recording and analysis bandwidth. To examine the effect of bandwidth on species identification, whistles were recorded from four delphinid species (Delphinus delphis, Stenella attenuata, S. coeruleoalba, and S. longirostris) in the eastern tropical Pacific ocean. Four spectrograms, each with a different upper frequency limit (20, 24, 30, and 40 kHz), were created for each whistle (n = 484). Eight variables (beginning, ending, minimum, and maximum frequency; duration; number of inflection points; number of steps; and presence/absence of harmonics) were measured from the fundamental frequency of each whistle. The whistle repertoires of all four species contained fundamental frequencies extending above 20 kHz. Overall correct classification using discriminant function analysis ranged from 30% for the 20-kHz upper frequency limit data to 37% for the 40-kHz upper frequency limit data. For the four species included in this study, an upper bandwidth limit of at least 24 kHz is required for an accurate representation of fundamental whistle contours.
High-efficiency frequency doubling of continuous-wave laser light.
Ast, Stefan; Nia, Ramon Moghadas; Schönbeck, Axel; Lastzka, Nico; Steinlechner, Jessica; Eberle, Tobias; Mehmet, Moritz; Steinlechner, Sebastian; Schnabel, Roman
2011-09-01
We report on the observation of high-efficiency frequency doubling of 1550 nm continuous-wave laser light in a nonlinear cavity containing a periodically poled potassium titanyl phosphate crystal (PPKTP). The fundamental field had a power of 1.10 W and was converted into 1.05 W at 775 nm, yielding a total external conversion efficiency of 95±1%. The latter value is based on the measured depletion of the fundamental field being consistent with the absolute values derived from numerical simulations. According to our model, the conversion efficiency achieved was limited by the nonperfect mode matching into the nonlinear cavity and by the nonperfect impedance matching for the maximum input power available. Our result shows that cavity-assisted frequency conversion based on PPKTP is well suited for low-decoherence frequency conversion of quantum states of light.
Effects of Weight Loss on Acoustic Parameters After Bariatric Surgery.
de Souza, Lourdes Bernadete Rocha; Dos Santos, Marquiony Marques; Pernambuco, Leandro Araújo; de Almeida Godoy, Cynthia Meira; da Silva Lima, Deysianne Meire
2018-05-01
Patients with morbid obesity may present vocal alterations, since large accumulation of fat in the vocal tract may interfere with voice production of these individuals. Verify the neck circumference and the acoustic parameters of voice in obese women, before and after the bariatric surgery, and compare the results with a control group, with normal weight. Observational, longitudinal, descriptive study with patients referred to the SCODE (Obesity Surgery and Related Disorders Center) in a university hospital. The sample consisted of 25 morbidly obese women, age range 28-43 years and 23 non-obese women, aged 21-41 years control group. To measure the neck circumference, a tape measure was used and all participants were seated upright with the head positioned in the Frankfort horizontal plane. The fundamental frequency was calculated through the sustained emission of vowel [a] at usual intensity and pitch, to measure the fundamental frequency of the voice, that is, how much the vocal fold vibrates per second. After the recording, participants were prompted to produce vowels [a], [i], and [u] sustained at usual intensity and pitch, and a stopwatch was used to measure the maximum phonation time, to verify the balance between myoelastic and dynamic forces of the larynx. After 8 months post-surgery, the patients were recruited to be re-evaluated using the same pre-surgical data collection procedures. There was an increase in the mean value of f0. The maximum phonation time of all vowels increased after surgery. Obese individuals with post-surgery weight loss may present neck circumference, fundamental frequency, and maximum phonation time values closer to the mean values of normal weight individuals. In this study, weight loss was sufficient to adjust the acoustic parameter measurements.
Characterization of Harmonic Signal Acquisition with Parallel Dipole and Multipole Detectors
NASA Astrophysics Data System (ADS)
Park, Sung-Gun; Anderson, Gordon A.; Bruce, James E.
2018-04-01
Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) is a powerful instrument for the study of complex biological samples due to its high resolution and mass measurement accuracy. However, the relatively long signal acquisition periods needed to achieve high resolution can serve to limit applications of FTICR-MS. The use of multiple pairs of detector electrodes enables detection of harmonic frequencies present at integer multiples of the fundamental cyclotron frequency, and the obtained resolving power for a given acquisition period increases linearly with the order of harmonic signal. However, harmonic signal detection also increases spectral complexity and presents challenges for interpretation. In the present work, ICR cells with independent dipole and harmonic detection electrodes and preamplifiers are demonstrated. A benefit of this approach is the ability to independently acquire fundamental and multiple harmonic signals in parallel using the same ions under identical conditions, enabling direct comparison of achieved performance as parameters are varied. Spectra from harmonic signals showed generally higher resolving power than spectra acquired with fundamental signals and equal signal duration. In addition, the maximum observed signal to noise (S/N) ratio from harmonic signals exceeded that of fundamental signals by 50 to 100%. Finally, parallel detection of fundamental and harmonic signals enables deconvolution of overlapping harmonic signals since observed fundamental frequencies can be used to unambiguously calculate all possible harmonic frequencies. Thus, the present application of parallel fundamental and harmonic signal acquisition offers a general approach to improve utilization of harmonic signals to yield high-resolution spectra with decreased acquisition time. [Figure not available: see fulltext.
Mixing of two co-directional Rayleigh surface waves in a nonlinear elastic material.
Morlock, Merlin B; Kim, Jin-Yeon; Jacobs, Laurence J; Qu, Jianmin
2015-01-01
The mixing of two co-directional, initially monochromatic Rayleigh surface waves in an isotropic, homogeneous, and nonlinear elastic solid is investigated using analytical, finite element method, and experimental approaches. The analytical investigations show that while the horizontal velocity component can form a shock wave, the vertical velocity component can form a pulse independent of the specific ratios of the fundamental frequencies and amplitudes that are mixed. This analytical model is then used to simulate the development of the fundamentals, second harmonics, and the sum and difference frequency components over the propagation distance. The analytical model is further extended to include diffraction effects in the parabolic approximation. Finally, the frequency and amplitude ratios of the fundamentals are identified which provide maximum amplitudes of the second harmonics as well as of the sum and difference frequency components, to help guide effective material characterization; this approach should make it possible to measure the acoustic nonlinearity of a solid not only with the second harmonics, but also with the sum and difference frequency components. Results of the analytical investigations are then confirmed using the finite element method and the experimental feasibility of the proposed technique is validated for an aluminum specimen.
Fundamentals of Zoological Scaling.
ERIC Educational Resources Information Center
Lin, Herbert
1982-01-01
The following animal characteristics are considered to determine how properties and characteristics of various systems change with system size (scaling): skeletal weight, speed of running, height and range of jumping, food consumption, heart rate, lifetime, locomotive efficiency, frequency of wing-flapping, and maximum sizes of flying and hovering…
Fiocchi, Serena; Liorni, Ilaria; Parazzini, Marta; Ravazzani, Paolo
2015-04-01
During the last decades studies addressing the effects of exposure to Extremely Low Frequency Electromagnetic Fields (ELF-EMF) have pointed out a possible link between those fields emitted by power lines and childhood leukaemia. They have also stressed the importance of also including in the assessment the contribution of frequency components, namely harmonics, other than the fundamental one. Based on the spectrum of supply voltage networks allowed by the European standard for electricity quality assessment, in this study the exposure of high-resolution three-dimensional models of foetuses to the whole harmonic content of a uniform magnetic field with a fundamental frequency of 50 Hz, was assessed. The results show that the main contribution in terms of induced electric fields to the foetal exposure is given by the fundamental frequency component. The harmonic components add some contributions to the overall level of electric fields, however, due to the extremely low permitted amplitude of the harmonic components with respect to the fundamental, their amplitudes are low. The level of the induced electric field is also much lower than the limits suggested by the guidelines for general public exposure, when the amplitude of the incident magnetic field is set at the maximum permitted level.
Fiocchi, Serena; Liorni, Ilaria; Parazzini, Marta; Ravazzani, Paolo
2015-01-01
During the last decades studies addressing the effects of exposure to Extremely Low Frequency Electromagnetic Fields (ELF-EMF) have pointed out a possible link between those fields emitted by power lines and childhood leukaemia. They have also stressed the importance of also including in the assessment the contribution of frequency components, namely harmonics, other than the fundamental one. Based on the spectrum of supply voltage networks allowed by the European standard for electricity quality assessment, in this study the exposure of high-resolution three-dimensional models of foetuses to the whole harmonic content of a uniform magnetic field with a fundamental frequency of 50 Hz, was assessed. The results show that the main contribution in terms of induced electric fields to the foetal exposure is given by the fundamental frequency component. The harmonic components add some contributions to the overall level of electric fields, however, due to the extremely low permitted amplitude of the harmonic components with respect to the fundamental, their amplitudes are low. The level of the induced electric field is also much lower than the limits suggested by the guidelines for general public exposure, when the amplitude of the incident magnetic field is set at the maximum permitted level. PMID:25837346
Poisson point process modeling for polyphonic music transcription.
Peeling, Paul; Li, Chung-fai; Godsill, Simon
2007-04-01
Peaks detected in the frequency domain spectrum of a musical chord are modeled as realizations of a nonhomogeneous Poisson point process. When several notes are superimposed to make a chord, the processes for individual notes combine to give another Poisson process, whose likelihood is easily computable. This avoids a data association step linking individual harmonics explicitly with detected peaks in the spectrum. The likelihood function is ideal for Bayesian inference about the unknown note frequencies in a chord. Here, maximum likelihood estimation of fundamental frequencies shows very promising performance on real polyphonic piano music recordings.
Radial oscillations and stability of compact stars in Eddington-inspired Born-Infeld gravity
NASA Astrophysics Data System (ADS)
Sham, Y.-H.; Lin, L.-M.; Leung, P. T.
2012-09-01
We study the hydrostatic equilibrium structure of compact stars in the Eddington-inspired Born-Infeld gravity recently proposed by Bañados and Ferreira [Phys. Rev. Lett. 105, 011101 (2010)]. We also develop a framework to study the radial perturbations and stability of compact stars in this theory. We find that the standard results of stellar stability still hold in this theory. The frequency square of the fundamental oscillation mode vanishes for the maximum-mass stellar configuration. The dependence of the oscillation mode frequencies on the coupling parameter κ of the theory is also investigated. We find that the fundamental mode is insensitive to the value of κ, while higher-order modes depend more strongly on κ.
NASA Astrophysics Data System (ADS)
Sudheer, S. K.; Pillai, V. P. Mahadevan; Nayar, V. U.
2006-12-01
Advances in Laser Technology and nonlinear Optical techniques can be effectively utilized for LIDAR applications in space and atmospheric sciences to achieve better flexibility and control of the available optical power. Using such devices, one can achieve highly accurate and resolved, measurement of the distribution for atmospheric scattering layers. In the present investigation a diode double end pumped high repetition rate, multi wavelength Nd:YAG laser is designed, fabricated and various laser beam parameters have been characterized for LIDAR applications. Nonlinear optical techniques have been employed to generate higher harmonics like 532nm, 355nm and 266nm for various spectral studies. The experimental setup mainly consists of two Fiber coupled pump laser diodes (Model FAP- 81-30C-800B, Coherent Inc, USA) with a maximum output power of 30Watt at a wavelength of 807-810nm at 30°C set temperature. A second harmonic LBO crystal cut for critical phase matching placed within the laser resonator is provided for converting a fraction of the fundamental beam to a second harmonic beam. A type II frequency tripling LBO nonlinear crystal (cut for critical phase matching) is also located inside the laser resonator. The third harmonic beam and the unconverted fundamental beam are then directed across a type I fourth harmonic LBO crystal cut for critical phase matching where a portion of the fundamental beam and a portion of the third harmonic beam are converted to a fourth harmonic frequency when both fundamental and third harmonic beams propagate through the frequency quadrupling crystal. The resulting beams which are the fundamental (1064nm), second harmonic (532nm), third harmonic (355nm) and fourth harmonic (266nm) are then directed to a fourth harmonic separator in which the fourth harmonic beam is separated from the fundamental beam. A maximum average power of 12W at 1064nm, 8W at 532nm, 5W at 355nm and 3W at 266nm have been measured at a repetition rate of 10KHz. A minimum pulse width of 25ns have been observed.
Sulter, A M; Wit, H P
1996-11-01
Glottal volume velocity waveform characteristics of 224 subjects, categorized in four groups according to gender and vocal training, were determined, and their relations to sound-pressure level, fundamental frequency, intra-oral pressure, and age were analyzed. Subjects phonated at three intensity conditions. The glottal volume velocity waveforms were obtained by inverse filtering the oral flow. Glottal volume velocity waveforms were parameterized with flow-based (minimum flow, ac flow, average flow, maximum flow declination rate) and time-based parameters (closed quotient, closing quotient, speed quotient), as well as with derived parameters (vocal efficiency and glottal resistance). Higher sound-pressure levels, intra-oral pressures, and flow-parameter values (ac flow, maximum flow declination rate) were observed, when compared with previous investigations. These higher values might be the result of the specific phonation tasks (stressed /ae/ vowel in a word and a sentence) or filtering processes. Few statistically significant (p < 0.01) differences in parameters were found between untrained and trained subjects [the maximum flow declination rate and the closing quotient were higher in trained women (p < 0.001), and the speed quotient was higher in trained men (p < 0.005)]. Several statistically significant parameter differences were found between men and women [minimum flow, ac flow, average flow, maximum flow declination rate, closing quotient, glottal resistance (p < 0.001), and closed quotient (p < 0.005)]. Significant effects of intensity condition were observed on ac flow, maximum flow declination rate, closing quotient, and vocal efficiency in women (p < 0.005), and on minimum flow, ac flow, average flow, maximum flow declination rate, closed quotient, and vocal efficiency in men (p < 0.01).
All-optical and broadband microwave fundamental/sub-harmonic I/Q down-converters.
Gao, Yongsheng; Wen, Aijun; Jiang, Wei; Fan, Yangyu; He, You
2018-03-19
Microwave I/Q down-converters are frequently used in image-reject super heterodyne receivers, zero intermediate frequency (zero-IF) receivers, and phase/frequency discriminators. However, due to the electronic bottleneck, conventional microwave I/Q mixers face a serious bandwidth limitation, I/Q imbalance, and even-order distortion. In this paper, photonic microwave fundamental and sub-harmonic I/Q down-converters are presented using a polarization division multiplexing dual-parallel Mach-Zehnder modulator (PDM-DPMZM). Thanks to all-optical manipulation, the proposed system features an ultra-wide operating band (7-40 GHz in the fundamental I/Q down-converter, and 10-40 GHz in the sub-harmonic I/Q down-converter) and an excellent I/Q balance (maximum 0.7 dB power imbalance and 1 degree phase imbalance). The conversion gain, noise figure (NF), even-order distortion, and spurious free dynamic range (SFDR) are also improved by LO power optimization and balanced detection. Using the proposed system, a high image rejection ratio is demonstrated for a super heterodyne receiver, and good EVMs over a wide RF power range is demonstrated for a zero-IF receiver. The proposed broadband photonic microwave fundamental and sub-harmonic I/Q down-converters may find potential applications in multi-band satellite, ultra-wideband radar and frequency-agile electronic warfare systems.
Distinct Acoustic Features and Glottal Changes Define Two Modes of Singing in Peking Opera.
Li, Gelin; Li, Haiqing; Hou, Qian; Jiang, Zhen
2018-04-06
We aimed to delineate the acoustic characteristics of the Laodan and Qingyi role in Peking Opera and define glottis closure states and mucosal wave changes during singing in the two roles. The range of singing in A4 (440 Hz) pitch in seven female Peking Opera singers was determined using two classic pieces of Peking Opera. Glottal changes during singing were examined by stroboscopic laryngoscope. The fundamental frequency of /i/ in the first 15 seconds of the two pieces and the /i/ pitch range were determined. The relative length of the glottis fissure and the relative maximum mucosal amplitude were calculated. Qingyi had significantly higher mean fundamental frequency than Laodan. The long-term average spectrum showed an obvious formant cluster near 3000 Hz in Laodan versus Qingyi. No formant cluster was observed in singing in the regular mode. Strobe laryngoscopy showed complete glottal closure in Laodan and incomplete glottal closure in Qingyi in the maximal glottis closure phase. The relative length of the glottis fissure of Laodan was significantly lower than that of Qingyi in the singing mode. The relative maximum mucosal amplitude of Qingyi was significantly lower than that of Laodan. The Laodan role and the Qingyi role in Peking Opera sing in a fundamental frequency range compatible with the respective use of da sang (big voice) and xiao sang (small voice). The morphological patterns of glottal changes also indicate that the Laodan role and the Qingyi role sing with da sang and xiao sang, respectively. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Mousavi Anzehaee, Mohammad; Adib, Ahmad; Heydarzadeh, Kobra
2015-10-01
The manner of microtremor data collection and filtering operation and also the method used for processing have a considerable effect on the accuracy of estimation of dynamic soil parameters. In this paper, running variance method was used to improve the automatic detection of data sections infected by local perturbations. In this method, the microtremor data running variance is computed using a sliding window. Then the obtained signal is used to remove the ranges of data affected by perturbations from the original data. Additionally, to determinate the fundamental frequency of a site, this study has proposed a statistical characteristics-based method. Actually, statistical characteristics, such as the probability density graph and the average and the standard deviation of all the frequencies corresponding to the maximum peaks in the H/ V spectra of all data windows, are used to differentiate the real peaks from the false peaks resulting from perturbations. The methods have been applied to the data recorded for the City of Meybod in central Iran. Experimental results show that the applied methods are able to successfully reduce the effects of extensive local perturbations on microtremor data and eventually to estimate the fundamental frequency more accurately compared to other common methods.
High-frequency resonant-tunneling oscillators
NASA Technical Reports Server (NTRS)
Brown, E. R.; Parker, C. D.; Calawa, A. R.; Manfra, M. J.; Chen, C. L.
1991-01-01
Advances in high-frequency resonant-tunneling-diode (RTD) oscillators are described. Oscillations up to a frequency of 420 GHz have been achieved in the GaAs/AlAs system. Recent results obtained with In0.53Ga0.47As/AlAs and InAs/AlSb RTDs show a greatly increased power density and indicate the potential for fundamental oscillations up to about 1 THz. These results are consistent with a lumped-element equivalent circuit model of the RTD. The model shows that the maximum oscillation frequency of the GaAs/AlAs RTDs is limited primarily by series resistance, and that the power density is limited by low peak-to-valley current ratio.
Diode-end-pumped continuously tunable single frequency Tm, Ho:LLF laser at 2.06 μm.
Zhang, Xinlu; Zhang, Su; Xiao, Nana; Cui, Jinhui; Zhao, Jiaqun; Li, Li
2014-03-10
We report on a laser diode-end-pumped continuously tunable single frequency Tm, Ho:LLF laser near room temperature. For transmission of 5%, the maximum single frequency output power of 221 mW at 2064.4 nm was obtained by using two uncoated etalons. The single frequency Tm, Ho:LLF laser operated on the fundamental transverse mode with an M2 factor of 1.13, and the output frequency could be tuned continuously near 1.5 GHz by angle tuning only of the 1 mm thick etalon. Furthermore, the influence of output coupler transmission on the laser performance was also investigated. The single frequency laser can be used as a seed laser for coherent Doppler lidar and differential absorption lidar systems.
a Comparative Analysis of Fluent and Cerebral Palsied Speech.
NASA Astrophysics Data System (ADS)
van Doorn, Janis Lee
Several features of the acoustic waveforms of fluent and cerebral palsied speech were compared, using six fluent and seven cerebral palsied subjects, with a major emphasis being placed on an investigation of the trajectories of the first three formants (vocal tract resonances). To provide an overall picture which included other acoustic features, fundamental frequency, intensity, speech timing (speech rate and syllable duration), and prevocalization (vocalization prior to initial stop consonants found in cerebral palsied speech) were also investigated. Measurements were made using repetitions of a test sentence which was chosen because it required large excursions of the speech articulators (lips, tongue and jaw), so that differences in the formant trajectories for the fluent and cerebral palsied speakers would be emphasized. The acoustic features were all extracted from the digitized speech waveform (10 kHz sampling rate): the fundamental frequency contours were derived manually, the intensity contours were measured using the signal covariance, speech rate and syllable durations were measured manually, as were the prevocalization durations, while the formant trajectories were derived from short time spectra which were calculated for each 10 ms of speech using linear prediction analysis. Differences which were found in the acoustic features can be summarized as follows. For cerebral palsied speakers, the fundamental frequency contours generally showed inappropriate exaggerated fluctuations, as did some of the intensity contours; the mean fundamental frequencies were either higher or the same as for the fluent subjects; speech rates were reduced, and syllable durations were longer; prevocalization was consistently present at the beginning of the test sentence; formant trajectories were found to have overall reduced frequency ranges, and to contain anomalous transitional features, but it is noteworthy that for any one cerebral palsied subject, the inappropriate trajectory pattern was generally reproducible. The anomalous transitional features took the form of (a) inappropriate transition patterns, (b) reduced frequency excursions, (c) increased transition durations, and (d) decreased maximum rates of frequency change.
Dynamic Behaviour and Seismic Response of Ground Supported Cylindrical Water Tanks
NASA Astrophysics Data System (ADS)
Asha, Joseph; Glory, Joseph
2018-05-01
Liquid storage tank such as in water distribution systems, petroleum plants etc., constitute a vital component of life line systems. Reducing earthquake effects on liquid storage tanks, to minimize the environmental and economic impact of these effects, have always been an important engineering concern. In this paper, the dynamic behavior of cylindrical ground supported concrete water tanks with different aspect ratios is investigated using finite element software ANSYS. The natural frequencies and modal responses are obtained for impulsive and convective modes of vibration. The natural frequency of vibration of the tank is observed to be the lowest at maximum water depth. The fundamental impulsive frequency increases as water level reduces and for water level less than 1/3 of tank height, there is significantly no change in impulsive frequency. The effect of wall flexibility on dynamic behavior of the tank is investigated by performing the modal analysis of flexible and rigid tanks. For a partially filled tank, the results of the present study are of significant relevance. The response of the tank to the transient loading as horizontal ground motion of El Centro earthquake is studied for various water heights. As the height of water on the tank increases, the ultimate maximum seismic response parameters are also observed to be increased. The location of maximum hoop stress varies in accordance with the variations in input ground motion and water fill condition whereas shear and bending moment are maximum at the base.
NASA Astrophysics Data System (ADS)
Chen, Guangwei; Li, Wenlei
2018-03-01
A broadband pulsed mid-infrared difference frequency generation (DFG) laser source based on MgO-doped congruent LiNbO3 bulk is experimentally demonstrated, which employs a homemade pulsed ytterbium-doped ring fiber laser and a continuous wave erbium-doped ring fiber laser to act as seed sources. The experimental results indicate that the perfect phase match crystal temperature is about 74.5∘C. The maximum spectrum bandwidth of idler is about 60 nm with suitable polarization states of fundamental lights. The central wavelength of idlers varies from 3293 nm to 3333 nm over the crystal temperature ranges of 70.4-76∘C. A jump of central wavelength exists around crystal temperature of 72∘C with variation of about 30 nm. The conversion efficiency of DFG can be tuned with the crystal temperature and polarization states of fundamental lights.
Perception of dissonance by people with normal hearing and sensorineural hearing loss
NASA Astrophysics Data System (ADS)
Tufts, Jennifer B.; Molis, Michelle R.; Leek, Marjorie R.
2005-08-01
The purpose of this study was to determine whether the perceived sensory dissonance of pairs of pure tones (PT dyads) or pairs of harmonic complex tones (HC dyads) is altered due to sensorineural hearing loss. Four normal-hearing (NH) and four hearing-impaired (HI) listeners judged the sensory dissonance of PT dyads geometrically centered at 500 and 2000 Hz, and of HC dyads with fundamental frequencies geometrically centered at 500 Hz. The frequency separation of the members of the dyads varied from 0 Hz to just over an octave. In addition, frequency selectivity was assessed at 500 and 2000 Hz for each listener. Maximum dissonance was perceived at frequency separations smaller than the auditory filter bandwidth for both groups of listners, but maximum dissonance for HI listeners occurred at a greater proportion of their bandwidths at 500 Hz than at 2000 Hz. Further, their auditory filter bandwidths at 500 Hz were significantly wider than those of the NH listeners. For both the PT and HC dyads, curves displaying dissonance as a function of frequency separation were more compressed for the HI listeners, possibly reflecting less contrast between their perceptions of consonance and dissonance compared with the NH listeners.
Killer whales (Orcinus orca) produce ultrasonic whistles.
Samarra, Filipa I P; Deecke, Volker B; Vinding, Katja; Rasmussen, Marianne H; Swift, René J; Miller, Patrick J O
2010-11-01
This study reports that killer whales, the largest dolphin, produce whistles with the highest fundamental frequencies ever reported in a delphinid. Using wide-band acoustic sampling from both animal-attached (Dtag) and remotely deployed hydrophone arrays, ultrasonic whistles were detected in three Northeast Atlantic populations but not in two Northeast Pacific populations. These results are inconsistent with analyses suggesting a correlation of maximum frequency of whistles with body size in delphinids, indicate substantial intraspecific variation in whistle production in killer whales, and highlight the importance of appropriate acoustic sampling techniques when conducting comparative analyses of sound repertoires.
Heller Murray, Elizabeth S.; Lien, Yu-An S.; Stepp, Cara E.
2016-01-01
Purpose This study examined the relationship between the acoustic measure relative fundamental frequency (RFF) and a kinematic estimate of laryngeal stiffness. Method Twelve healthy adults (mean age = 22.7 years, SD = 4.4; 10 women, 2 men) produced repetitions of /ifi/ while varying their vocal effort during simultaneous acoustic and video nasendoscopic recordings. RFF was determined from the last 10 voicing cycles before the voiceless obstruent (RFF offset) and the first 10 cycles of revoicing (RFF onset). A kinematic stiffness ratio was calculated for the vocal fold adductory gesture during revoicing by normalizing the maximum angular velocity by the maximum glottic angle during the voiceless obstruent. Results A linear mixed effect model indicated that RFF offset and onset were significant predictors of the kinematic stiffness ratios. The model accounted for 52% of the variance in the kinematic data. Individual relationships between RFF and kinematic stiffness ratios varied across participants, with at least moderate negative correlations in 83% of participants for RFF offset but only 40% of participants for RFF onset. Conclusions RFF significantly predicted kinematic estimates of laryngeal stiffness in healthy speakers and has the potential to be a useful clinical indicator of laryngeal tension. Further research is needed in individuals with voice disorders. PMID:27936279
NASA Astrophysics Data System (ADS)
Volodin, Ilya A.; Volodina, Elena V.; Frey, Roland; Kirilyuk, Vadim E.; Naidenko, Sergey V.
2017-06-01
In neonate ruminants, the acoustic structure of vocalizations may depend on sex, vocal anatomy, hormonal profiles and body mass and on environmental factors. In neonate wild-living Mongolian gazelles Procapra gutturosa, hand-captured during biomedical monitoring in the Daurian steppes at the Russian-Mongolian border, we spectrographically analysed distress calls and measured body mass of 22 individuals (6 males, 16 females). For 20 (5 male, 15 female) of these individuals, serum testosterone levels were also analysed. In addition, we measured relevant dimensions of the vocal apparatus (larynx, vocal folds, vocal tract) in one stillborn male Mongolian gazelle specimen. Neonate distress calls of either sex were high in maximum fundamental frequency (800-900 Hz), but the beginning and minimum fundamental frequencies were significantly lower in males than in females. Body mass was larger in males than in females. The levels of serum testosterone were marginally higher in males. No correlations were found between either body mass or serum testosterone values and any acoustic variable for males and females analysed together or separately. We discuss that the high-frequency calls of neonate Mongolian gazelles are more typical for closed-habitat neonate ruminants, whereas other open-habitat neonate ruminants (goitred gazelle Gazella subgutturosa, saiga antelope Saiga tatarica and reindeer Rangifer tarandus) produce low-frequency (<200 Hz) distress calls. Proximate cause for the high fundamental frequency of distress calls of neonate Mongolian gazelles is their very short, atypical vocal folds (4 mm) compared to the 7-mm vocal folds of neonate goitred gazelles, producing distress calls as low as 120 Hz.
Gigahertz flexible graphene transistors for microwave integrated circuits.
Yeh, Chao-Hui; Lain, Yi-Wei; Chiu, Yu-Chiao; Liao, Chen-Hung; Moyano, David Ricardo; Hsu, Shawn S H; Chiu, Po-Wen
2014-08-26
Flexible integrated circuits with complex functionalities are the missing link for the active development of wearable electronic devices. Here, we report a scalable approach to fabricate self-aligned graphene microwave transistors for the implementation of flexible low-noise amplifiers and frequency mixers, two fundamental building blocks of a wireless communication receiver. A devised AlOx T-gate structure is used to achieve an appreciable increase of device transconductance and a commensurate reduction of the associated parasitic resistance, thus yielding a remarkable extrinsic cutoff frequency of 32 GHz and a maximum oscillation frequency of 20 GHz; in both cases the operation frequency is an order of magnitude higher than previously reported. The two frequencies work at 22 and 13 GHz even when subjected to a strain of 2.5%. The gigahertz microwave integrated circuits demonstrated here pave the way for applications which require high flexibility and radio frequency operations.
Pressure sensitivity of flow oscillations in postocclusive reactive skin hyperemia.
Strucl, M; Peterec, D; Finderle, Z; Maver, J
1994-05-01
Skin blood flow was monitored using a laser-Doppler (LD) flowmeter in 21 healthy volunteers after an occlusion of the digital arteries. The peripheral vascular bed was exposed to occlusion ischemia of varying duration (1, 4, or 8 min) and to a change in digital arterial pressure produced by different positions of the arm above heart level to characterize the pattern of LD flow oscillations in postocclusive reactive hyperemia (PRH) and to elucidate the relevance of metabolic and myogenic mechanisms in governing its fundamental frequency. The descending part of the hyperemic flow was characterized by the appearance of conspicuous periodic oscillations with a mean fundamental frequency of 7.2 +/- 1.5 cycles/min (SD, n = 9), as assessed by a Fourier transform frequency analysis of 50-s sections of flow. The mean respiratory frequency during the periods of flow frequency analysis was 17.0 +/- 2.2 (SD, n = 9), and the PRH oscillations remained during apnea in all tested subjects. The area under the maximum flow curve increased significantly with prolongation of the occlusion (paired t test, P < 0.001; n = 9), but showed no dependence on the estimated blood pressure in the digital arteries, which suggests the predominant role of a metabolic component in this part of the PRH response. In contrast, the fundamental frequency of PRH oscillations exhibited a significant decrease with a reduction in the estimated digital arterial pressure (linear regression, b = 0.08, P < 0.001; n = 12), but did not change with the prolongation of arterial occlusion despite a significant increase in mean LD flow (paired t test, P < 0.001; n = 9).(ABSTRACT TRUNCATED AT 250 WORDS)
Ansari, Mohd. Zahid; Cho, Chongdu; Kim, Jooyong; Bang, Booun
2009-01-01
Arrays of microcantilevers are increasingly being used as physical, biological, and chemical sensors in various applications. To improve the sensitivity of microcantilever sensors, this study analyses and compares the deflection and vibration characteristics of rectangular and trapezoidal profile microcantilevers. Three models of each profile are investigated. The cantilevers are analyzed for maximum deflection, fundamental resonant frequency and maximum stress. The surface stress is modelled as in-plane tensile force applied on the top edge of the microcantilevers. A commercial finite element analysis software ANSYS is used to analyze the designs. Results show paddled trapezoidal profile microcantilevers have better sensitivity. PMID:22574041
Tracking Helicopters with a Seismic Array
NASA Astrophysics Data System (ADS)
Eibl, Eva P. S.; Lokmer, Ivan; Bean, Christopher J.; Akerlie, Eggert
2015-04-01
We observed that the pressure or acoustic wave created by the rotor blades of a helicopter can couple to the ground even at 30 km distance where it creates a signal strong enough to be detected by a seismometer. The signal is harmonic tremor with a fundamental frequency downgliding with the inflection point at e.g. 14 Hz and two equally spaced overtones up to the Nyquist frequency of 50 Hz. No difference in the amplitudes between the fundamental frequency and higher harmonics was observed. Such a signature is a consequence of the regularly repeating pressure pulses generated by the helicopter's rotor blades. The signal was recorded by a seven station broadband array with an aperture of 1.6 km. Our spacing is close enough to record the signal at all stations and far enough to observe traveltime differences. The separation of the spectral lines corresponds to the time interval between the repeating sources. The highlighted harmonics contain information about the spectral content of the single source as our signal corresponds to the convolution of an infinite comb function and a single pulse. As we see all harmonics and they have the same amplitude up to the Nyquist frequency we can deduce that the frequency content of the single pulse is flat i.e. it is effectively a delta function up to the Nyquist frequency. We perform a detailed spectral and location analysis of the signal, and compare our results with the known information on the helicopter's speed, location, the frequency of the blades rotation and the amount of blades. This analysis is based on the characteristic shape of the curve i.e. speed of the gliding, minimum and maximum fundamental frequency, amplitudes at the inflection points at different stations and traveltimes deduced from the inflection points at different stations. This observation has an educative value, because the same principle could be used for the analysis of the volcanic harmonic tremor. Harmonic volcanic tremor usually has fundamental frequencies below 10 Hz but frequency downgliding and upgliding up to 30 Hz was observed e.g. on Redoubt volcano. Due to the characteristic shape of the helicopter signal it is nevertheless rather unlikely that this signal is mistaken for volcanic tremor. The helicopter gives us a robust way of testing the method and possible application of the method to volcanic harmonic tremor.
A CW green laser emission by self-sum-frequency-mixing in Nd:GdCOB crystal
NASA Astrophysics Data System (ADS)
Shao, Y.; Jin, H. J.; Lin, J.; Zhang, D.; Tao, Z. H.; Zhang, T. Y.; Li, Y. L.; Ruan, Q. R.
2011-10-01
A compact and efficient green laser light at 538 nm produced by self-sum-frequency-mixing of both fundamental infrared laser waves (1061 and 1091 nm) in Nd:GdCa4O(BO3)3 (Nd:GdCOB) crystal is demonstrated. With 18.2 W of diode pump power, a maximum output power of 1.73 W in the green spectral range at 538 nm has been achieved, corresponding to an optical-to-optical conversion efficiency of 9.5%; the output power stability over 30 min is better than 3%. To the best of our knowledge, this is first work on self-sum-frequency-mixing of a diode pumped Nd:GdCOB laser.
One node driving synchronisation
NASA Astrophysics Data System (ADS)
Wang, Chengwei; Grebogi, Celso; Baptista, Murilo S.
2015-12-01
Abrupt changes of behaviour in complex networks can be triggered by a single node. This work describes the dynamical fundamentals of how the behaviour of one node affects the whole network formed by coupled phase-oscillators with heterogeneous coupling strengths. The synchronisation of phase-oscillators is independent of the distribution of the natural frequencies, weakly depends on the network size, but highly depends on only one key oscillator whose ratio between its natural frequency in a rotating frame and its coupling strength is maximum. This result is based on a novel method to calculate the critical coupling strength with which the phase-oscillators emerge into frequency synchronisation. In addition, we put forward an analytical method to approximately calculate the phase-angles for the synchronous oscillators.
One node driving synchronisation
Wang, Chengwei; Grebogi, Celso; Baptista, Murilo S.
2015-01-01
Abrupt changes of behaviour in complex networks can be triggered by a single node. This work describes the dynamical fundamentals of how the behaviour of one node affects the whole network formed by coupled phase-oscillators with heterogeneous coupling strengths. The synchronisation of phase-oscillators is independent of the distribution of the natural frequencies, weakly depends on the network size, but highly depends on only one key oscillator whose ratio between its natural frequency in a rotating frame and its coupling strength is maximum. This result is based on a novel method to calculate the critical coupling strength with which the phase-oscillators emerge into frequency synchronisation. In addition, we put forward an analytical method to approximately calculate the phase-angles for the synchronous oscillators. PMID:26656718
Fundamentals of Electrical Propulsion Plant Design,
1982-04-06
through connection of resonant filters or through use of multiphase conversion power circuits. Figure 9.25. Block Diagram of a Frequency Converter Control...first harmonic, active power Pa’ consumed by the converter at the point of application of this emf, is determined from expression P. = 3EM i cos i...armature shunting contactor K3 KDD diesel starting contactor K.U KZ protection contactor K3 KMM maximum power contactor KM KO compensating winding KO
Initial results of stimulated radiation measurements during the HAARP campaign of September 2017
NASA Astrophysics Data System (ADS)
Yellu, A. D.; Scales, W. A.; Mahmoudian, A.; Siefring, C.; Bernhardt, P.
2018-02-01
Initial results of stimulated electromagnetic radiation observed during an ionosphere heating experiment conducted at the High-Frequency Active Auroral Program (HAARP) facility are reported. The frequency of the pump wave used in the heating is in the neighborhood of the third harmonic of the electron cyclotron frequency, and of interest are simulated electromagnetic emissions (SEEs) within ? kHz of the heating frequency known as narrowband SEE (NSEE) and the commonly known wideband SEE (WSEE) which occur within ? kHz of the pump wave frequency. With the transmit power maintained at maximum, and all other conditions of the experiment invariable, the characteristics of NSEE and WSEE as time progresses from the time the transmitter is switched on are detailed in the results. The dependence of the characteristics of the NSEE and WSEE with temporal evolution into the heating cycle are observed to be fundamentally different.
An approximation function for frequency constrained structural optimization
NASA Technical Reports Server (NTRS)
Canfield, R. A.
1989-01-01
The purpose is to examine a function for approximating natural frequency constraints during structural optimization. The nonlinearity of frequencies has posed a barrier to constructing approximations for frequency constraints of high enough quality to facilitate efficient solutions. A new function to represent frequency constraints, called the Rayleigh Quotient Approximation (RQA), is presented. Its ability to represent the actual frequency constraint results in stable convergence with effectively no move limits. The objective of the optimization problem is to minimize structural weight subject to some minimum (or maximum) allowable frequency and perhaps subject to other constraints such as stress, displacement, and gage size, as well. A reason for constraining natural frequencies during design might be to avoid potential resonant frequencies due to machinery or actuators on the structure. Another reason might be to satisy requirements of an aircraft or spacecraft's control law. Whatever the structure supports may be sensitive to a frequency band that must be avoided. Any of these situations or others may require the designer to insure the satisfaction of frequency constraints. A further motivation for considering accurate approximations of natural frequencies is that they are fundamental to dynamic response constraints.
NASA Astrophysics Data System (ADS)
Wang, Junmin; Zhang, Kong; Ge, Yulong; Guo, Shanlong
2016-06-01
We have demonstrated 1.61 W of 780 nm single-frequency continuous-wave laser output with a semi-monolithic periodically poled potassium titanyl phosphate (PPKTP) crystal doubler pumped by a 2-W erbium-doped fiber amplifier boosted 1560 nm diode laser. The measured maximum doubling efficiency is 77%, and the practical value should be 80% when taking into account the fundamental-wave mode matching efficiency. The measured beam quality factor of 780 nm output, M2, is better than 1.04. Typical root-mean-square fluctuation of 780 nm output is less than 0.5% in 30 minutes. This compact frequency doubler has good mechanical stability, and can be employed for many applications, such as laser cooling and trapping, atomic coherent control, atomic interferometer, and quantum frequency standard with rubidium atoms.
The influence of fundamental frequency on perceived duration in spectrally comparable sounds
Aalto, Daniel; Simko, Juraj; Vainio, Martti
2017-01-01
The perceived duration of a sound is affected by its fundamental frequency and intensity: higher sounds are judged to be longer, as are sounds with greater intensity. Since increasing intensity lengthens the perceived duration of the auditory object, and increasing the fundamental frequency increases the sound’s perceived loudness (up to ca. 3 kHz), frequency modulation of duration could be potentially explained by a confounding effect where the primary cause of the modulation would be variations in intensity. Here, a series of experiments are described that were designed to disentangle the contributions of fundamental frequency, intensity, and duration to perceived loudness and duration. In two forced-choice tasks, participants judged duration and intensity differences between two sounds varying simultaneously in intensity, fundamental frequency, fundamental frequency gliding range, and duration. The results suggest that fundamental frequency and intensity each have an impact on duration judgments, while frequency gliding range did not influence the present results. We also demonstrate that the modulation of perceived duration by sound fundamental frequency cannot be fully explained by the confounding relationship between frequency and intensity. PMID:28879063
The influence of fundamental frequency on perceived duration in spectrally comparable sounds.
Dawson, Caitlin; Aalto, Daniel; Simko, Juraj; Vainio, Martti
2017-01-01
The perceived duration of a sound is affected by its fundamental frequency and intensity: higher sounds are judged to be longer, as are sounds with greater intensity. Since increasing intensity lengthens the perceived duration of the auditory object, and increasing the fundamental frequency increases the sound's perceived loudness (up to ca. 3 kHz), frequency modulation of duration could be potentially explained by a confounding effect where the primary cause of the modulation would be variations in intensity. Here, a series of experiments are described that were designed to disentangle the contributions of fundamental frequency, intensity, and duration to perceived loudness and duration. In two forced-choice tasks, participants judged duration and intensity differences between two sounds varying simultaneously in intensity, fundamental frequency, fundamental frequency gliding range, and duration. The results suggest that fundamental frequency and intensity each have an impact on duration judgments, while frequency gliding range did not influence the present results. We also demonstrate that the modulation of perceived duration by sound fundamental frequency cannot be fully explained by the confounding relationship between frequency and intensity.
NASA Astrophysics Data System (ADS)
Monroe, Roberta Lynn
The intrinsic fundamental frequency effect among vowels is a vocalic phenomenon of adult speech in which high vowels have higher fundamental frequencies in relation to low vowels. Acoustic investigations of children's speech have shown that variability of the speech signal decreases as children's ages increase. Fundamental frequency measures have been suggested as an indirect metric for the development of laryngeal stability and coordination. Studies of the intrinsic fundamental frequency effect have been conducted among 8- and 9-year old children and in infants. The present study investigated this effect among 2- and 4-year old children. Eight 2-year old and eight 4-year old children produced four vowels, /ae/, /i/, /u/, and /a/, in CVC syllables. Three measures of fundamental frequency were taken. These were mean fundamental frequency, the intra-utterance standard deviation of the fundamental frequency, and the extent to which the cycle-to-cycle pattern of the fundamental frequency was predicted by a linear trend. An analysis of variance was performed to compare the two age groups, the four vowels, and the earlier and later repetitions of the CVC syllables. A significant difference between the two age groups was detected using the intra-utterance standard deviation of the fundamental frequency. Mean fundamental frequencies and linear trend analysis showed that voicing of the preceding consonant determined the statistical significance of the age-group comparisons. Statistically significant differences among the fundamental frequencies of the four vowels were not detected for either age group.
Soul and Musical Theater: A Comparison of Two Vocal Styles.
Hallqvist, Hanna; Lã, Filipa M B; Sundberg, Johan
2017-03-01
The phonatory and resonatory characteristics of nonclassical styles of singing have been rarely analyzed in voice research. Six professional singers volunteered to sing excerpts from two songs pertaining to the musical theater and to the soul styles of singing. Voice source parameters and formant frequencies were analyzed by inverse filtering tones, sung at the same fundamental frequencies in both excerpts. As compared with musical theater, the soul style was characterized by significantly higher subglottal pressure and maximum flow declination rate. Yet sound pressure level was lower, suggesting higher glottal resistance. The differences would be the effects of firmer glottal adduction and a greater frequency separation between the first formant and its closest spectrum partial in soul than in musical theater. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Yu, Chengzhu; Hansen, John H L
2017-03-01
Human physiology has evolved to accommodate environmental conditions, including temperature, pressure, and air chemistry unique to Earth. However, the environment in space varies significantly compared to that on Earth and, therefore, variability is expected in astronauts' speech production mechanism. In this study, the variations of astronaut voice characteristics during the NASA Apollo 11 mission are analyzed. Specifically, acoustical features such as fundamental frequency and phoneme formant structure that are closely related to the speech production system are studied. For a further understanding of astronauts' vocal tract spectrum variation in space, a maximum likelihood frequency warping based analysis is proposed to detect the vocal tract spectrum displacement during space conditions. The results from fundamental frequency, formant structure, as well as vocal spectrum displacement indicate that astronauts change their speech production mechanism when in space. Moreover, the experimental results for astronaut voice identification tasks indicate that current speaker recognition solutions are highly vulnerable to astronaut voice production variations in space conditions. Future recommendations from this study suggest that successful applications of speaker recognition during extended space missions require robust speaker modeling techniques that could effectively adapt to voice production variation caused by diverse space conditions.
1.55-μm mode-locked quantum-dot lasers with 300 MHz frequency tuning range
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sadeev, T., E-mail: tagir@mailbox.tu-berlin.de; Arsenijević, D.; Bimberg, D.
2015-01-19
Passive mode-locking of two-section quantum-dot mode-locked lasers grown by metalorganic vapor phase epitaxy on InP is reported. 1250-μm long lasers exhibit a wide tuning range of 300 MHz around the fundamental mode-locking frequency of 33.48 GHz. The frequency tuning is achieved by varying the reverse bias of the saturable absorber from 0 to −2.2 V and the gain section current from 90 to 280 mA. 3 dB optical spectra width of 6–7 nm leads to ex-facet optical pulses with full-width half-maximum down to 3.7 ps. Single-section quantum-dot mode-locked lasers show 0.8 ps broad optical pulses after external fiber-based compression. Injection current tuning from 70 tomore » 300 mA leads to 30 MHz frequency tuning.« less
Integrated optic single-ring filter for narrowband phase demodulation
NASA Astrophysics Data System (ADS)
Madsen, C. K.
2017-05-01
Integrated optic notch filters are key building blocks for higher-order spectral filter responses and have been demonstrated in many technology platforms from dielectrics (such as Si3N4) to semiconductors (Si photonics). Photonic-assisted RF processing applications for notch filters include identifying and filtering out high-amplitude, narrowband signals that may be interfering with the desired signal, including undesired frequencies detected in radar and free-space optical links. The fundamental tradeoffs for bandwidth and rejection depth as a function of the roundtrip loss and coupling coefficient are investigated along with the resulting spectral phase response for minimum-phase and maximum-phase responses compared to the critical coupling condition and integration within a Mach Zehnder interferometer. Based on a full width at half maximum criterion, it is shown that maximum-phase responses offer the smallest bandwidths for a given roundtrip loss. Then, a new role for passive notch filters in combination with high-speed electro-optic phase modulation is explored around narrowband phase-to-amplitude demodulation using a single ring operating on one sideband. Applications may include microwave processing and instantaneous frequency measurement (IFM) for radar, space and defense applications.
Genetic-evolution-based optimization methods for engineering design
NASA Technical Reports Server (NTRS)
Rao, S. S.; Pan, T. S.; Dhingra, A. K.; Venkayya, V. B.; Kumar, V.
1990-01-01
This paper presents the applicability of a biological model, based on genetic evolution, for engineering design optimization. Algorithms embodying the ideas of reproduction, crossover, and mutation are developed and applied to solve different types of structural optimization problems. Both continuous and discrete variable optimization problems are solved. A two-bay truss for maximum fundamental frequency is considered to demonstrate the continuous variable case. The selection of locations of actuators in an actively controlled structure, for minimum energy dissipation, is considered to illustrate the discrete variable case.
Investigations of High Pressure Acoustic Waves in Resonators with Seal-Like Features
NASA Technical Reports Server (NTRS)
Daniels, Christopher C.; Steinetz, Bruce M.; Finkbeiner, Joshua R.; Li, Xiao-Fan; Raman, Ganesh
2004-01-01
1) Standing waves with maximum pressures of 188 kPa have been produced in resonators containing ambient pressure air; 2) Addition of structures inside the resonator shifts the fundamental frequency and decreases the amplitude of the generated pressure waves; 3) Addition of holes to the resonator does reduce the magnitude of the acoustic waves produced, but their addition does not prohibit the generation of large magnitude non-linear standing waves; 4) The feasibility of reducing leakage using non-linear acoustics has been confirmed.
McAleavey, Stephen A
2014-05-01
Shear wave induced phase encoding (SWIPE) imaging generates ultrasound backscatter images of tissue-like elastic materials by using traveling shear waves to encode the lateral position of the scatters in the phase of the received echo. In contrast to conventional ultrasound B-scan imaging, SWIPE offers the potential advantages of image formation without beam focusing or steering from a single transducer element, lateral resolution independent of aperture size, and the potential to achieve relatively high lateral resolution with low frequency ultrasound. Here a Fourier series description of the phase modulated echo signal is developed, demonstrating that echo harmonics at multiples of the shear wave frequency reveal target k-space data at identical multiples of the shear wavenumber. Modulation transfer functions of SWIPE imaging systems are calculated for maximum shear wave acceleration and maximum shear constraints, and compared with a conventionally focused aperture. The relative signal-to-noise ratio of the SWIPE method versus a conventionally focused aperture is found through these calculations. Reconstructions of wire targets in a gelatin phantom using 1 and 3.5 MHz ultrasound and a cylindrical shear wave source are presented, generated from the fundamental and second harmonic of the shear wave modulation frequency, demonstrating weak dependence of lateral resolution with ultrasound frequency.
Uncertainty quantification of voice signal production mechanical model and experimental updating
NASA Astrophysics Data System (ADS)
Cataldo, E.; Soize, C.; Sampaio, R.
2013-11-01
The aim of this paper is to analyze the uncertainty quantification in a voice production mechanical model and update the probability density function corresponding to the tension parameter using the Bayes method and experimental data. Three parameters are considered uncertain in the voice production mechanical model used: the tension parameter, the neutral glottal area and the subglottal pressure. The tension parameter of the vocal folds is mainly responsible for the changing of the fundamental frequency of a voice signal, generated by a mechanical/mathematical model for producing voiced sounds. The three uncertain parameters are modeled by random variables. The probability density function related to the tension parameter is considered uniform and the probability density functions related to the neutral glottal area and the subglottal pressure are constructed using the Maximum Entropy Principle. The output of the stochastic computational model is the random voice signal and the Monte Carlo method is used to solve the stochastic equations allowing realizations of the random voice signals to be generated. For each realization of the random voice signal, the corresponding realization of the random fundamental frequency is calculated and the prior pdf of this random fundamental frequency is then estimated. Experimental data are available for the fundamental frequency and the posterior probability density function of the random tension parameter is then estimated using the Bayes method. In addition, an application is performed considering a case with a pathology in the vocal folds. The strategy developed here is important mainly due to two things. The first one is related to the possibility of updating the probability density function of a parameter, the tension parameter of the vocal folds, which cannot be measured direct and the second one is related to the construction of the likelihood function. In general, it is predefined using the known pdf. Here, it is constructed in a new and different manner, using the own system considered.
Frequency modulation indicator, Arnold’s web and diffusion in the Stark Quadratic-Zeeman problem
NASA Astrophysics Data System (ADS)
Cordani, Bruno
2008-11-01
We notice that the fundamental frequencies of a slightly perturbed integrable Hamiltonian system are not time-constant inside a resonance but frequency modulated, as is evident from pendulum models and wavelet analysis. Exploiting an intrinsic imprecision inherent to the numerical frequency analysis algorithm itself, hence transforming a drawback into an opportunity, we define the Frequency Modulation Indicator, a very sensitive tool in detecting where fundamental frequencies are modulated, localizing so the resonances without having to resort, as in other methods, to the integration of variational equations. For the Kepler problem, the space of the orbits with a fixed energy has the topology of the product of two 2-spheres. The perturbation Hamiltonian, averaged over the mean anomaly, has surely a maximum and a minimum, to which correspond two periodic orbits in physical space. Studying the neighbourhood of these two elliptic stable points, we are able to define adapted action-angle variables, for example, the usual but “SO(4)-rotated” Delaunay variables. The procedure, implemented in the program KEPLER, is performed transparently for the user, providing a general scheme suited for generic perturbation. The method is then applied to the Stark-Quadratic-Zeeman problem, displaying very clearly the Arnold web of the resonances. Sectioning transversely one of the resonance strips so highlighted and performing a numerical frequency analysis, one is able to locate with great precision the thin stochastic layer surrounding a separatrix. Another very long (10 8 revolutions) frequency analysis on an orbit starting here reveals, as expected, a well defined pattern, which ensures that the integration errors do not eject the point out of the layer, and moreover a very slow drift in the frequency values, clearly due to Arnold diffusion.
On the modulation of low-frequency quasi-periodic oscillations in black hole transients
NASA Astrophysics Data System (ADS)
Pawar, Devraj D.; Motta, Sara; Shanthi, K.; Bhattacharya, Dipankar; Belloni, Tomaso
2015-04-01
We studied the properties of the low-frequency quasi-periodic oscillations detected in a sample of six black hole candidates (XTE J1550-564, H 1743-322, XTE J1859+226, 4U 1630-47, GX 339-4, XTE J1650-500) observed by the Rossi XTE satellite. We analysed the relation between the full width at half-maximum and the frequency of all the narrow peaks detected in power density spectra where a type-C QPO is observed. Our goal was to understand the nature of the modulation of the signal by comparing the properties of different harmonic peaks in the power density spectrum. We find that for the sources in our sample the width of the fundamental and of the first harmonic are compatible with a frequency modulation, while that of the sub-harmonic is independent of frequency, possibly indicating the presence of an additional modulation in amplitude. We compare our results with those obtained earlier from GRS 1915+105 and XTE J1550-564.
33 CFR 86.03 - Limits of fundamental frequencies.
Code of Federal Regulations, 2010 CFR
2010-07-01
... of fundamental frequencies. To ensure a wide variety of whistle characteristics, the fundamental... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Limits of fundamental frequencies. 86.03 Section 86.03 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhihua, Huang; Jianning, Fu; Weikai, Zong
During the operation of the Chinese Small Telescope Array (CSTAR) in Dome A of Antarctica in the years 2008, 2009, and 2010, large amounts of photometric data have been obtained for variable stars in the CSTAR field. We present here the study of one of six RR Lyrae variables, Y Oct, observed with CSTAR in Dome A, Antarctica. Photometric data in the i band were obtained in 2008 and 2010, with a duty cycle (defined as the fraction of time representing scientifically available data to CSTAR observation time) of about 44% and 52%, respectively. In 2009, photometric data in themore » g and r bands were gathered for this star, with a duty cycle of 65% and 60%, respectively. Fourier analysis of the data in the three bands only shows the fundamental frequency and its harmonics, which is characteristic of the non-Blazhko RR Lyrae variables. Values of the fundamental frequency and the amplitudes, as well as the total pulsation amplitude, are obtained from the data in the three bands separately. The amplitude of the fundamental frequency and the total pulsation amplitude in the g band are the largest, and those in the i band the smallest. Two-hundred fifty-one times of maximum are obtained from the three seasons of data, which are analyzed together with 38 maximum times provided in the GEOS RR Lyrae database. A period change rate of −0.96 ± 0.07 days Myr{sup −1} is then obtained, which is a surprisingly large negative value. Based on relations available in the literature, the following physical parameters are derived: [Fe/H] = −1.41 ± 0.14, M{sub V} = 0.696 ± 0.014 mag, V−K = 1.182 ± 0.028 mag, logT{sub eff} = 3.802 ± 0.003 K, logg = 2.705 ± 0.004, logL/L{sub ⊙} = 1.625 ± 0.013, and logM/M{sub ⊙} = −0.240 ± 0.019.« less
Nilsonne, A; Sundberg, J; Ternström, S; Askenfelt, A
1988-02-01
A method of measuring the rate of change of fundamental frequency has been developed in an effort to find acoustic voice parameters that could be useful in psychiatric research. A minicomputer program was used to extract seven parameters from the fundamental frequency contour of tape-recorded speech samples: (1) the average rate of change of the fundamental frequency and (2) its standard deviation, (3) the absolute rate of fundamental frequency change, (4) the total reading time, (5) the percent pause time of the total reading time, (6) the mean, and (7) the standard deviation of the fundamental frequency distribution. The method is demonstrated on (a) a material consisting of synthetic speech and (b) voice recordings of depressed patients who were examined during depression and after improvement.
Faez, Telli; Skachkov, Ilya; Versluis, Michel; Kooiman, Klazina; de Jong, Nico
2012-09-01
The dynamics of coated microbubbles was studied in an in vivo model. Biotinylated lipid-coated microbubbles were prepared in-house and were injected into a chick embryo chorioallantoic membrane (CAM) model on the fifth day of incubation. The microbubbles, ranging between 1.0 and 3.5 μm in diameter, were insonified in the frequency range of 4-7 MHz. Two amplitudes of acoustic pressure were applied: 300 kPa and 400 kPa. The fundamental and subharmonic responses were recorded optically with an ultra-fast camera (Brandaris 128) at 20 million frames per second. A subharmonic response was observed for 44% of the studied bubbles. From the data the frequency of the maximum fundamental and subharmonic response was derived for each individual bubble and resulted in the resonance curves of the microbubbles. All the bubbles showed shell (strain) hardening behavior for a higher acoustic pressure. We conclude that the subharmonic oscillations observed in this study belonged to the transmit at resonance (TR) regime. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Vyunishev, A. M.; Arkhipkin, V. G.; Baturin, I. S.; Akhmatkhanov, A. R.; Shur, V. Ya; Chirkin, A. S.
2018-04-01
The frequency doubling of femtosecond laser pulses in a two-dimensional (2D) rectangular nonlinear photonic lattice with hexagonal domains is studied experimentally and theoretically. The broad fundamental spectrum enables frequency conversion under nonlinear Bragg diffraction for a series of transverse orders at a fixed longitudinal quasi-phase-matching order. The consistent nonstationary theory of the frequency doubling of femtosecond laser pulses is developed using the representation based on the reciprocal lattice of the structure. The calculated spatial distribution of the second-harmonic spectral intensity agrees well with the experimental data. The condition for multiple nonlinear Bragg diffraction in a 2D nonlinear photonic lattice is offered. The hexagonal shape of the domains contributes to multibeam second harmonic excitation. The maximum conversion efficiency for a series of transverse orders in the range 0.01%-0.03% is obtained.
High-order Stokes generation in a KTP Raman laser pumped by a passively Q-switched ND:YLF laser
NASA Astrophysics Data System (ADS)
Wang, Maorong; Zhong, Kai; Mei, Jialin; Guo, Shibei; Xu, Degang; Yao, Jianquan
2015-12-01
High-order Stokes wave was observed in an x-cut KTP crystal based on stimulated Raman scattering (SRS) pumped by a passively Q-switched Nd:YLF laser with a Cr4+:YAG saturable absorber. Output spectra including the fundamental wave at 1047 nm and six Stokes wavelengths at 1077 nm, 1110 nm, 1130 nm, 1143 nm, 1164 nm, 1180 nm based on two Raman frequency shift at 267.4 cm-1 and 693.0 cm-1 were obtained simultaneously. We also detected green light generation with output power of 12 mW from self frequency mixing in the KTP crystal. The maximum total output power reached 452 mW at the repetition frequency of 8.1 kHz, corresponding to the optical-to-optical conversion efficiency of 4.61% and pump-to-Raman conversion efficiency of 3.6%.
NASA Astrophysics Data System (ADS)
Zhu, Pengfei; Zhang, Chaomin; Zhu, Kun; Ping, Yunxia; Song, Pei; Sun, Xiaohui; Wang, Fuxin; Yao, Yi
2018-03-01
We demonstrate an efficient and compact ultraviolet laser at 303 nm generated by intracavity frequency doubling of a continuous wave (CW) laser diode-pumped Pr3+:YLiF4 laser at 607 nm. A cesium lithium borate (CLBO) crystal, cut for critical type I phase matching at room temperature, is used for second-harmonic generation (SHG) of the fundamental laser. By using an InGaN laser diode array emitting at 444.3 nm with a maximum incident power of 10 W, as high as 68 mW of CW output power at 303 nm is achieved. The output power stability in 4 h is better than 2.85%. To the best of our knowledge, this is high efficient UV laser generated by frequency doubling of an InGaN laser diode array pumped Pr3+:YLiF4 laser.
Perception of the fundamental frequencies of children's voices by trained and untrained listeners.
Wilson, F B; Wellen, C J; Kimbarow, M L
1983-10-01
This study was designed to determine if trained voice clinicians were better than untrained listeners in judging differences in the fundamental frequencies of children's voices. We also attempted to determine the degree of difference in fundamental frequency necessary for accurate judgments. Finally, ability to perceive pitch differences in speaking voices was correlated with ability to judge puretone stimuli. Results indicated that trained clinicians were no better at judging average fundamental frequency than were untrained listeners. Both groups performed at chance level until differences in vocal fundamental frequency exceeded 20 Hz. Finally, there was no correlation between subjects' success on standardized puretone pitch tests and ability to judge average pitch in the speaking voice.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, X. H.; Fu, J. N.; Zha, Q., E-mail: jnfu@bnu.edu.cn
Time-series photometric observations were made for the SX Phoenicis star XX Cyg between 2007 and 2011 at the Xinglong Station of National Astronomical Observatories of China. With the light curves derived from the new observations, we do not detect any secondary maximum in the descending portion of the light curves of XX Cyg, as reported in some previous work. Frequency analysis of the light curves confirms a fundamental frequency f{sub 0} = 7.4148 cycles day{sup -1} and up to 19 harmonics, 11 of which are newly detected. However, no secondary mode of pulsation is detected from the light curves. Themore » O-C diagram, produced from 46 newly determined times of maximum light combined with those derived from the literature, reveals a continuous period increase with the rate of (1/P)(dP/dt) = 1.19(13) Multiplication-Sign 10{sup -8} yr{sup -1}. Theoretical rates of period change due to the stellar evolution were calculated with a modeling code. The result shows that the observed rate of period change is fully consistent with period change caused by evolutionary behavior predicted by standard theoretical models.« less
Tsujino, Jiromaru; Hongoh, Misugi; Yoshikuni, Masafumi; Hashii, Hidekazu; Ueoka, Tetsugi
2004-04-01
The welding characteristics of 27, 40 and 67 kHz ultrasonic plastic welding systems that are driven at only the fundamental-resonance frequency vibration were compared, and also those of the welding systems that were driven at the fundamental and several higher resonance frequencies simultaneously were studied. At high frequency, welding characteristics can be improved due to the larger vibration loss of plastic materials. For welding of rather thin or small specimens, as the fundamental frequency of these welding systems is higher and the numbers of driven higher frequencies are driven simultaneously, larger welded area and weld strength were obtained.
Characterizing resonant component in speech: A different view of tracking fundamental frequency
NASA Astrophysics Data System (ADS)
Dong, Bin
2017-05-01
Inspired by the nonlinearity and nonstationarity and the modulations in speech, Hilbert-Huang Transform and cyclostationarity analysis are employed to investigate the speech resonance in vowel in sequence. Cyclostationarity analysis is not directly manipulated on the target vowel, but on its intrinsic mode functions one by one. Thanks to the equivalence between the fundamental frequency in speech and the cyclic frequency in cyclostationarity analysis, the modulation intensity distributions of the intrinsic mode functions provide much information for the estimation of the fundamental frequency. To highlight the relationship between frequency and time, the pseudo-Hilbert spectrum is proposed to replace the Hilbert spectrum here. After contrasting the pseudo-Hilbert spectra of and the modulation intensity distributions of the intrinsic mode functions, it finds that there is usually one intrinsic mode function which works as the fundamental component of the vowel. Furthermore, the fundamental frequency of the vowel can be determined by tracing the pseudo-Hilbert spectrum of its fundamental component along the time axis. The later method is more robust to estimate the fundamental frequency, when meeting nonlinear components. Two vowels [a] and [i], picked up from a speech database FAU Aibo Emotion Corpus, are applied to validate the above findings.
Predicting Achievable Fundamental Frequency Ranges in Vocalization Across Species
Titze, Ingo; Riede, Tobias; Mau, Ted
2016-01-01
Vocal folds are used as sound sources in various species, but it is unknown how vocal fold morphologies are optimized for different acoustic objectives. Here we identify two main variables affecting range of vocal fold vibration frequency, namely vocal fold elongation and tissue fiber stress. A simple vibrating string model is used to predict fundamental frequency ranges across species of different vocal fold sizes. While average fundamental frequency is predominantly determined by vocal fold length (larynx size), range of fundamental frequency is facilitated by (1) laryngeal muscles that control elongation and by (2) nonlinearity in tissue fiber tension. One adaptation that would increase fundamental frequency range is greater freedom in joint rotation or gliding of two cartilages (thyroid and cricoid), so that vocal fold length change is maximized. Alternatively, tissue layers can develop to bear a disproportionate fiber tension (i.e., a ligament with high density collagen fibers), increasing the fundamental frequency range and thereby vocal versatility. The range of fundamental frequency across species is thus not simply one-dimensional, but can be conceptualized as the dependent variable in a multi-dimensional morphospace. In humans, this could allow for variations that could be clinically important for voice therapy and vocal fold repair. Alternative solutions could also have importance in vocal training for singing and other highly-skilled vocalizations. PMID:27309543
Investigation of parameters affecting treatment time in MRI-guided transurethral ultrasound therapy
NASA Astrophysics Data System (ADS)
N'Djin, W. A.; Burtnyk, M.; Chopra, R.; Bronskill, M. J.
2010-03-01
MRI-guided transurethral ultrasound therapy shows promise for minimally invasive treatment of localized prostate cancer. Real-time MR temperature feedback enables the 3D control of thermal therapy to define an accurate region within the prostate. Previous in-vivo canine studies showed the feasibility of this method using transurethral planar transducers. The aim of this simulation study was to reduce the procedure time, while maintaining treatment accuracy by investigating new combinations of treatment parameters. A numerical model was used to simulate a multi-element heating applicator rotating inside the urethra in 10 human prostates. Acoustic power and rotation rate were varied based on the feedback of the temperature in the prostate. Several parameters were investigated for improving the treatment time. Maximum acoustic power and rotation rate were optimized interdependently as a function of prostate radius and transducer operating frequency, while avoiding temperatures >90° C in the prostate. Other trials were performed on each parameter separately, with the other parameter fixed. The concept of using dual-frequency transducers was studied, using the fundamental frequency or the 3rd harmonic component depending on the prostate radius. The maximum acoustic power which could be used decreased as a function of the prostate radius and the frequency. Decreasing the frequency (9.7-3.0 MHz) or increasing the power (10-20 W.cm-2) led to treatment times shorter by up to 50% under appropriate conditions. Dual-frequency configurations, while helpful, tended to have less impact on treatment times. Treatment accuracy was maintained and critical adjacent tissues like the rectal wall remained protected. The interdependence between power and frequency may require integrating multi-parametric functions inside the controller for future optimizations. As a first approach, however, even slight modifications of key parameters can be sufficient to reduce treatment time.
Issues in vibration energy harvesting
NASA Astrophysics Data System (ADS)
Zhang, Hui; Corr, Lawrence R.; Ma, Tianwei
2018-05-01
In this study, fundamental issues related to bandwidth and nonlinear resonance in vibrational energy harvesting devices are investigated. The results show that using bandwidth as a criterion to measure device performance can be misleading. For a linear device, an enlarged bandwidth is achieved at the cost of sacrificing device performance near resonance, and thus widening the bandwidth may offer benefits only when the natural frequency of the linear device cannot match the dominant excitation frequency. For a nonlinear device, since the principle of superposition does not apply, the ''broadband" performance improvements achieved for single-frequency excitations may not be achievable for multi-frequency excitations. It is also shown that a large-amplitude response based on the traditional ''nonlinear resonance" does not always result in the optimal performance for a nonlinear device because of the negative work done by the excitation, which indicates energy is returned back to the excitation. Such undesired negative work is eliminated at global resonance, a generalized resonant condition for both linear and nonlinear systems. While the linear resonance is a special case of global resonance for a single-frequency excitation, the maximum potential of nonlinear energy harvesting can be reached for multi-frequency excitations by using global resonance to simultaneously harvest energy distributed over multiple frequencies.
NASA Astrophysics Data System (ADS)
Freeman, Allison
This research examined the fundamental frequency and perturbation (jitter % and shimmer %) measures in young adult (20-30 year-old) and middle-aged adult (40-55 year-old) smokers and non-smokers; there were 36 smokers and 36 non-smokers. Acoustic analysis was carried out utilizing one task: production of sustained /a/. These voice samples were analyzed utilizing Multi-Dimensional Voice Program (MDVP) software, which provided values for fundamental frequency, jitter %, and shimmer %.These values were analyzed for trends regarding smoking status, age, and gender. Statistical significance was found regarding the fundamental frequency, jitter %, and shimmer % for smokers as compared to non-smokers; smokers were found to have significantly lower fundamental frequency values, and significantly higher jitter % and shimmer % values. Statistical significance was not found regarding fundamental frequency, jitter %, and shimmer % for age group comparisons. With regard to gender, statistical significance was found regarding fundamental frequency; females were found to have statistically higher fundamental frequencies as compared to males. However, the relationships between gender and jitter % and shimmer % lacked statistical significance. These results indicate that smoking negatively affects voice quality. This study also examined the ability of untrained listeners to identify smokers and non-smokers based on their voices. Results of this voice perception task suggest that listeners are not accurately able to identify smokers and non-smokers, as statistical significance was not reached. However, despite a lack of significance, trends in data suggest that listeners are able to utilize voice quality to identify smokers and non-smokers.
Chaos in a spatially-developing plane mixing layer
NASA Technical Reports Server (NTRS)
Broze, J. G.; Hussain, Fazle; Buell, J. C.
1988-01-01
A spatially-developing plane mixing layer was analyzed for chaotic behavior. A direct numerical simulation of the Navier-Stokes equations in a 2-D domain infinite in y and having inflow-outflow boundary conditions in x was used for data. Spectra, correlation dimension and the largest Lyapunov exponent were computed as functions of downstream distance x. When forced at a single (fundamental) frequency with maximum amplitude, the flow is periodic at the inflow but becomes aperiodic with increasing x. The aperiodic behavior is caused by the presence of a noisy subharmonic caused by the feedback between the necessarily nonphysical inflow and outflow boundary conditions. In order to overshadow this noise the flow was also studied with the same fundamental forcing and added random forcing of amplitude upsilon prime sub R/delta U = 0.01 at the inlet. Results were qualitatively the same in both cases: for small x, spectral peaks were sharp and dimension was nearly 1, but as x increased a narrowband spectral peak grew, spectra decayed exponentially at high frequencies and dimension increased to greater than 3. Based on these results, the flow appears to exhibit deterministic chaos. However, at no location was the largest Lyapunov exponent found to be significantly greater than zero.
Martens, Heidi; Van Nuffelen, Gwen; Dekens, Tomas; Hernández-Díaz Huici, Maria; Kairuz Hernández-Díaz, Hector Arturo; De Letter, Miet; De Bodt, Marc
2015-01-01
Most studies on treatment of prosody in individuals with dysarthria due to Parkinson's disease are based on intensive treatment of loudness. The present study investigates the effect of intensive treatment of speech rate and intonation on the intelligibility of individuals with dysarthria due to Parkinson's disease. A one group pretest-posttest design was used to compare intelligibility, speech rate, and intonation before and after treatment. Participants included eleven Dutch-speaking individuals with predominantly moderate dysarthria due to Parkinson's disease, who received five one-hour treatment sessions per week during three weeks. Treatment focused on lowering speech rate and magnifying the phrase final intonation contrast between statements and questions. Intelligibility was perceptually assessed using a standardized sentence intelligibility test. Speech rate was automatically assessed during the sentence intelligibility test as well as during a passage reading task and a storytelling task. Intonation was perceptually assessed using a sentence reading task and a sentence repetition task, and also acoustically analyzed in terms of maximum fundamental frequency. After treatment, there was a significant improvement of sentence intelligibility (effect size .83), a significant increase of pause frequency during the passage reading task, a significant improvement of correct listener identification of statements and questions, and a significant increase of the maximum fundamental frequency in the final syllable of questions during both intonation tasks. The findings suggest that participants were more intelligible and more able to manipulate pause frequency and statement-question intonation after treatment. However, the relationship between the change in intelligibility on the one hand and the changes in speech rate and intonation on the other hand is not yet fully understood. Results are nuanced in the light of the operated research design. The reader will be able to: (1) describe the effect of intensive speech rate and intonation treatment on intelligibility of speakers with dysarthria due to PD, (2) describe the effect of intensive speech rate treatment on rate manipulation by speakers with dysarthria due to PD, and (3) describe the effect of intensive intonation treatment on manipulation of the phrase final intonation contrast between statements and questions by speakers with dysarthria due to PD. Copyright © 2015 Elsevier Inc. All rights reserved.
Fourier transform spectroscopy of the nu3 band of the N3 radical
NASA Technical Reports Server (NTRS)
Brazier, C. R.; Bernath, P. F.; Burkholder, James B.; Howard, Carleton J.
1988-01-01
The nu3 transitions of N3 radicals produced by HN3-Cl reactions in a multipass cell (effective path length 100 m) are investigated experimentally using a Fourier-transform spectrometer with maximum resolution 0.004/cm. A total of 176 rotation-vibration lines are listed in a table and used, in combination with published data on 240 optical lines (Douglas and Jones, 1965), to determine the nu3 molecular constants. The lower-than-expected value of the nu3 fundamental frequency (1644.6784/cm) is attributed to the vibronic interaction discussed by Kawaguchi et al. (1981).
From micro- to nanomagnetic dots: evolution of the eigenmode spectrum on reducing the lateral size
NASA Astrophysics Data System (ADS)
Carlotti, G.; Gubbiotti, G.; Madami, M.; Tacchi, S.; Hartmann, F.; Emmerling, M.; Kamp, M.; Worschech, L.
2014-07-01
Brillouin light scattering experiments and micromagnetic simulations have been exploited to investigate the spectrum of thermally excited magnetic eigenmodes in 10 nm-thick elliptical Permalloy dots, when the longer axis D is scaled down from about 1000 to 100 nm. It is shown that for D larger than about 200 nm the characteristics of the spin-wave eigenmodes are dominated by dipolar energy, while for D in the range of about 100 to 200 nm exchange energy effects cause qualitative and quantitative differences in the spin-wave spectrum. In this ‘mesoscopic’ regime, the usual classification scheme, involving one fundamental mode with large average magnetization and many other modes collected in families with specific symmetries, no longer holds. Rather, one finds the simultaneous presence of two modes with ‘fundamental’ character, i.e. with a significant and comparable value of the average dynamical magnetization: the former is at larger frequency and has its maximum amplitude at the dot's centre, while the latter occurs at lower frequency and is localized at the dot's edges. Interestingly, the maximum intensity swaps from the higher frequency mode to the lower frequency one, just when the dot size is reduced from about 200 to 100 nm. This is relevant in view of the exploitation of nanodots for the design of nanomagnetic devices with lateral dimensions in the above interval, such as memory cells, logic gates, reading heads and spin-torque oscillators.
NASA Technical Reports Server (NTRS)
Holliday, Ezekiel S. (Inventor)
2014-01-01
Vibrations of a principal machine are reduced at the fundamental and harmonic frequencies by driving the drive motor of an active balancer with balancing signals at the fundamental and selected harmonics. Vibrations are sensed to provide a signal representing the mechanical vibrations. A balancing signal generator for the fundamental and for each selected harmonic processes the sensed vibration signal with adaptive filter algorithms of adaptive filters for each frequency to generate a balancing signal for each frequency. Reference inputs for each frequency are applied to the adaptive filter algorithms of each balancing signal generator at the frequency assigned to the generator. The harmonic balancing signals for all of the frequencies are summed and applied to drive the drive motor. The harmonic balancing signals drive the drive motor with a drive voltage component in opposition to the vibration at each frequency.
NASA Astrophysics Data System (ADS)
Dong, Jun; Wang, Xiaolei; Zhang, Mingming; Wang, Xiaojie; He, Hongsen
2018-04-01
Structured optical vortices with 4 phase singularities have been generated in a laser diode pumped continuous-wave Yb:Y3Al5O12/YVO4 (Yb:YAG/YVO4) Raman microchip laser. The broadband comb-like first order Stokes laser emitting spectrum including 30 longitudinal modes covers from 1072.49 nm to 1080.13 nm with a bandwidth of 7.64 nm, which is generated with the Raman shift 259 cm-1 of the c-cut YVO4 crystal converted from the fundamental laser around 1.05 μm. Pump power dependent optical vortex beams are attributed to overlap of the Stokes laser field with the fundamental laser field caused by dynamically changing the coupling losses of the fundamental laser field. The maximum output power is 1.16 W, and the optical-to-optical efficiency is 18.4%. This work provides a method for generating structured optical vortices with an optical frequency comb in solid-state Raman microchip lasers, which have potential applications in quantum computations, micro-machining, and information processing.
Acoustic analysis of speech variables during depression and after improvement.
Nilsonne, A
1987-09-01
Speech recordings were made of 16 depressed patients during depression and after clinical improvement. The recordings were analyzed using a computer program which extracts acoustic parameters from the fundamental frequency contour of the voice. The percent pause time, the standard deviation of the voice fundamental frequency distribution, the standard deviation of the rate of change of the voice fundamental frequency and the average speed of voice change were found to correlate to the clinical state of the patient. The mean fundamental frequency, the total reading time and the average rate of change of the voice fundamental frequency did not differ between the depressed and the improved group. The acoustic measures were more strongly correlated to the clinical state of the patient as measured by global depression scores than to single depressive symptoms such as retardation or agitation.
Individual Differences in the Frequency-Following Response: Relation to Pitch Perception
Coffey, Emily B. J.; Colagrosso, Emilia M. G.; Lehmann, Alexandre; Schönwiesner, Marc; Zatorre, Robert J.
2016-01-01
The scalp-recorded frequency-following response (FFR) is a measure of the auditory nervous system’s representation of periodic sound, and may serve as a marker of training-related enhancements, behavioural deficits, and clinical conditions. However, FFRs of healthy normal subjects show considerable variability that remains unexplained. We investigated whether the FFR representation of the frequency content of a complex tone is related to the perception of the pitch of the fundamental frequency. The strength of the fundamental frequency in the FFR of 39 people with normal hearing was assessed when they listened to complex tones that either included or lacked energy at the fundamental frequency. We found that the strength of the fundamental representation of the missing fundamental tone complex correlated significantly with people's general tendency to perceive the pitch of the tone as either matching the frequency of the spectral components that were present, or that of the missing fundamental. Although at a group level the fundamental representation in the FFR did not appear to be affected by the presence or absence of energy at the same frequency in the stimulus, the two conditions were statistically distinguishable for some subjects individually, indicating that the neural representation is not linearly dependent on the stimulus content. In a second experiment using a within-subjects paradigm, we showed that subjects can learn to reversibly select between either fundamental or spectral perception, and that this is accompanied both by changes to the fundamental representation in the FFR and to cortical-based gamma activity. These results suggest that both fundamental and spectral representations coexist, and are available for later auditory processing stages, the requirements of which may also influence their relative strength and thus modulate FFR variability. The data also highlight voluntary mode perception as a new paradigm with which to study top-down vs bottom-up mechanisms that support the emerging view of the FFR as the outcome of integrated processing in the entire auditory system. PMID:27015271
Modeling of classical swirl injector dynamics
NASA Astrophysics Data System (ADS)
Ismailov, Maksud M.
The knowledge of the dynamics of a swirl injector is crucial in designing a stable liquid rocket engine. Since the swirl injector is a complex fluid flow device in itself, not much work has been conducted to describe its dynamics either analytically or by using computational fluid dynamics techniques. Even the experimental observation is limited up to date. Thus far, there exists an analytical linear theory by Bazarov [1], which is based on long-wave disturbances traveling on the free surface of the injector core. This theory does not account for variation of the nozzle reflection coefficient as a function of disturbance frequency, and yields a response function which is strongly dependent on the so called artificial viscosity factor. This causes an uncertainty in designing an injector for the given operational combustion instability frequencies in the rocket engine. In this work, the author has studied alternative techniques to describe the swirl injector response, both analytically and computationally. In the analytical part, by using the linear small perturbation analysis, the entire phenomenon of unsteady flow in swirl injectors is dissected into fundamental components, which are the phenomena of disturbance wave refraction and reflection, and vortex chamber resonance. This reveals the nature of flow instability and the driving factors leading to maximum injector response. In the computational part, by employing the nonlinear boundary element method (BEM), the author sets the boundary conditions such that they closely simulate those in the analytical part. The simulation results then show distinct peak responses at frequencies that are coincident with those resonant frequencies predicted in the analytical part. Moreover, a cold flow test of the injector related to this study also shows a clear growth of instability with its maximum amplitude at the first fundamental frequency predicted both by analytical methods and BEM. It shall be noted however that Bazarov's theory does not predict the resonant peaks. Overall this methodology provides clearer understanding of the injector dynamics compared to Bazarov's. Even though the exact value of response is not possible to obtain at this stage of theoretical, computational, and experimental investigation, this methodology sets the starting point from where the theoretical description of reflection/refraction, resonance, and their interaction between each other may be refined to higher order to obtain its more precise value.
Development of a multistage compliant mechanism with new boundary constraint
NASA Astrophysics Data System (ADS)
Ling, Mingxiang; Cao, Junyi; Jiang, Zhou; Li, Qisheng
2018-01-01
This paper presents a piezo-actuated compliant mechanism with a new boundary constraint to provide concurrent large workspace and high dynamic frequency for precision positioning or other flexible manipulation applications. A two-stage rhombus-type displacement amplifier with the "sliding-sliding" boundary constraint is presented to maximize the dynamic frequency while retaining a large output displacement. The vibration mode is also improved by the designed boundary constraint. A theoretical kinematic model of the compliant mechanism is established to optimize the geometric parameters, and a prototype is fabricated with a compact dimension of 60 mm × 60 mm × 12 mm. The experimental testing shows that the maximum stroke is approximately 0.6 mm and the output stiffness is 1.1 N/μm with the fundamental frequency of larger than 2.2 kHz. Lastly, the excellent performance of the presented compliant mechanism is compared with several mechanisms in the previous literature. As a conclusion, the presented boundary constraint strategy provides a new way to balance the trade-off between the frequency response and the stroke range widely existed in compliant mechanisms.
Evaluation of nonuniform field exposures with coupling factors.
Sunohara, Tetsu; Hirata, Akimasa; Laakso, Ilkka; De Santis, Valerio; Onishi, Teruo
2015-10-21
In this study, the safety compliance for nonuniform field exposures is discussed using coupling factor concepts. The coupling factor, which is defined in the International Electrotechnical Commission 62311 standard, is extended to consider the effects of harmonics and also to apply to the specific absorption rate (for frequencies up to 30 MHz). The proposed compliance procedure is applied to and demonstrated for a prototype wireless power transfer (WPT) system with induction coupling operating at the fundamental frequency in 140 kHz band. First, measurements confirm that the perturbation of the external magnetic field strength and S11 parameter of a one-loop antenna by a human-equivalent phantom are sufficiently small, suggesting the applicability of the magneto-quasi-static approximation to frequencies up to 30 MHz. Then, the frequency characteristics of the coupling factor are derived for the WPT system. For the prototype system that is not optimized for commercial usage, the maximum allowable transmitting power is relaxed by a factor of 23 with the proposed procedure. The contribution of the harmonics decreased the allowable transmitting power by 39%, indicating their importance for safety compliance.
Laser diode and pumped Cr:Yag passively Q-switched yellow-green laser at 543 nm
NASA Astrophysics Data System (ADS)
Yao, Y.; Ling, Zhao; Li, B.; Qu, D. P.; Zhou, K.; Zhang, Y. B.; Zhao, Y.; Zheng, Q.
2013-03-01
Efficient and compact yellow green pulsed laser output at 543 nm is generated by frequency doubling of a passively Q-switched end diode-pumped Nd:YVO4 laser at 1086 nm under the condition of sup-pressing the higher gain transition near 1064 nm. With 15 W of diode pump power and the frequency doubling crystal LBO, as high as 1.58 W output power at 543 nm is achieved. The optical to optical conversion efficiency from the corresponding Q-switched fundamental output to the yellow green output is 49%. The peak power of the Q-switched yellow green pulse laser is up to 30 kW with 5 ns pulse duration. The output power stability over 8 hours is better than 2.56% at the maximum output power. To the best of our knowledge, this is the highest watt-level laser at 543 nm generated by frequency doubling of a passively Q-switched end diode pumped Nd:YVO4 laser at 1086 nm.
Ropagnol, X; Khorasaninejad, M; Raeiszadeh, M; Safavi-Naeini, S; Bouvier, M; Côté, C Y; Laramée, A; Reid, M; Gauthier, M A; Ozaki, T
2016-05-30
We report the generation of free space terahertz (THz) pulses with energy up to 8.3 ± 0.2 µJ from an encapsulated interdigitated ZnSe Large Aperture Photo-Conductive Antenna (LAPCA). An aperture of 12.2 cm2 is illuminated using a 400 nm pump laser with multi-mJ energies at 10 Hz repetition rate. The calculated THz peak electric field is 331 ± 4 kV/cm with a spectrum characterized by a median frequency of 0.28 THz. Given its relatively low frequency, this THz field will accelerate charged particles efficiently having very large ponderomotive energy of 15 ± 1 eV for electrons in vacuum. The scaling of the emission is studied with respect to the dimensions of the antenna, and it is observed that the capacitance of the LAPCA leads to a severe decrease in and distortion of the biasing voltage pulse, fundamentally limiting the maximum applied bias field and consequently the maximum energy of the radiated THz pulses. In order to demonstrate the advantages of this source in the strong field regime, an open-aperture Z-scan experiment was performed on n-doped InGaAs, which showed significant absorption bleaching.
Currents, drag, and sediment transport induced by a tsunami
Lacy, Jessica R.; Rubin, David M.; Buscombe, Daniel
2012-01-01
We report observations of water surface elevation, currents, and suspended sediment concentration (SSC) from a 10-m deep site on the inner shelf in northern Monterey Bay during the arrival of the 2010 Chile tsunami. Velocity profiles were measured from 3.5 m above the bed (mab) to the surface at 2 min intervals, and from 0.1 to 0.7 mab at 1 Hz. SSC was determined from the acoustic backscatter of the near-bed profiler. The initial tsunami waves were directed cross shore and had a period of approximately 16 min. Maximum wave height was 1.1 m, and maximum current speed was 0.36 m/s. During the strongest onrush, near-bed velocities were clearly influenced by friction and a logarithmic boundary layer developed, extending more than 0.3 mab. We estimated friction velocity and bed shear stress from the logarithmic profiles. The logarithmic structure indicates that the flow can be characterized as quasi-steady at these times. At other phases of the tsunami waves, the magnitude of the acceleration term was significant in the near-bed momentum equation, indicating unsteady flow. The maximum tsunami-induced bed shear stress (0.4 N/m2) exceeded the critical shear stress for the medium-grained sand on the seafloor. Cross-shore sediment flux was enhanced by the tsunami. Oscillations of water surface elevation and currents continued for several days. The oscillations were dominated by resonant frequencies, the most energetic of which was the fundamental longitudinal frequency of Monterey Bay. The maximum current speed (hourly-timescale) in 18 months of observations occurred four hours after the tsunami arrived.
Casado, Juan C; O'Connor, Carlos; Angulo, María S; Adrián, José A
2016-01-01
With the development of new ENT techniques, many male transsexuals who wish to become women usually request a surgical procedure to raise the fundamental frequency of the voice (feminization). The ENT specialist and the voice-therapist have to use an interdisciplinary approach to this growing social demand. The aim of this study was to show the results in a group of transsexual patients after Wendler's anterior synechiae, with additional voice-therapy treatment. Ten male transexulas who wish to become women patients who had Wendler glottoplasty and voice-therapy were assessed. The surgical procedure consisted of a de-epithelialization of the anterior third of both vocal folds; this area was sutured and the surface of both vocal folds was vaporised with laser diode. Pre- and postsurgery voice assessment consisted of measuring fundamental frequency (Fo) and maximum phonation time, administering the transgender self-assessment questionnaire (TSEQ) and obtaining perceptual voice assessment by inter-rater agreement. All the male transsexuals who wish to become women patients significantly increased their Fo (106 Hz on average) after the treatment. Furthermore, significant improvements were shown in self-reported satisfaction and in the degree of voice feminization. No improvements in the maximum phonation time were observed. Wendler glottoplasty is a surgical procedure to contribute to feminising the voice, with good medium-term results and without noteworthy medical complications. The increase in vocal tone was observed using several pre- and post-surgery control measures and voice therapy. Copyright © 2014 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.
NASA Astrophysics Data System (ADS)
Futami, Yoshisuke; Minamoto, Chihiro; Kudoh, Satoshi
2018-05-01
The frequencies and absorption intensities of the five kinds of conformers of 1,3-butanediol with the same carbon skeleton (GG‧) were calculated by anharmonic calculation for the fundamentals and first overtones of OH stretching vibrations. The four kinds of conformers form intramolecular hydrogen bonds and one conformer did not. Intramolecular hydrogen bond formation shifted the frequency of fundamental and first overtone of H-bonding OH stretching vibration to the lower frequency. The absorption intensities of the fundamentals as well as the vibrational anharmonicities increased upon hydrogen bond formation, while the intensities of first overtones decreased. The differences of conformers were clearly seen in the frequencies of the first overtones of free OH.
NASA Technical Reports Server (NTRS)
Theobald, M. A.
1977-01-01
The outdoor propagation of spherically spreading sound waves of finite amplitude was investigated. The main purpose of the experiments was to determine the extent to which the outdoor environment, mainly random inhomogeneity of the medium, affects finite amplitude propagation. Periodic sources with fundamental frequencies in the range 6 to 8 kHz and source levels SPLlm from 140 to 149 dB were used. The sources were an array of 7 to 10 horn drivers and a siren. The propagation path was vertical and parallel to an 85 m tower, whose elevator carried the traveling microphone. The general conclusions drawn from the experimental results were as follows. The inhomogeneities caused significant fluctuations in the instantaneous acoustic signal, but with sufficient time averaging of the measured harmonic levels, the results were comparable to results expected for propagation in a quiet medium. Propagation data for the fundamental of the siren approached within 1 dB of the weak shock saturation levels. Extra attenuation on the order of 8 dB was observed. The measurements generally confirmed the predictions of several theoretical models. The maximum propagation distance was 36 m. The narrowbeam arrays were much weaker sources. Nonlinear propagation distortion was produced, but the maximum value of extra attenuation measured was 1.5 dB. The maximum propagation distance was 76 m. The behavior of the asymetric waveforms received in one experiment qualitatively suggested that beam type diffraction effects were present. The role of diffraction of high intensity sound waves in radiation from a single horn was briefly investigated.
Role of antenna modes and field enhancement in second harmonic generation from dipole nanoantennas.
de Ceglia, Domenico; Vincenti, Maria Antonietta; De Angelis, Costantino; Locatelli, Andrea; Haus, Joseph W; Scalora, Michael
2015-01-26
We study optical second harmonic generation from metallic dipole antennas with narrow gaps. Enhancement of the fundamental-frequency field in the gap region plays a marginal role on conversion efficiency. In the symmetric configuration, i.e., with the gap located at the center of the antenna axis, reducing gap size induces a significant red-shift of the maximum conversion efficiency peak. Either enhancement or inhibition of second-harmonic emission may be observed as gap size is decreased, depending on the antenna mode excited at the harmonic frequency. The second-harmonic signal is extremely sensitive to the asymmetry introduced by gap's displacements with respect to the antenna center. In this situation, second-harmonic light can couple to all the available antenna modes. We perform a multipolar analysis that allows engineering the far-field SH emission and find that the interaction with quasi-odd-symmetry modes generates radiation patterns with a strong dipolar component.
A novel high-performance high-frequency SOI MESFET by the damped electric field
NASA Astrophysics Data System (ADS)
Orouji, Ali A.; Khayatian, Ahmad; Keshavarzi, Parviz
2016-06-01
In this paper, we introduce a novel silicon-on-insulator (SOI) metal-semiconductor field-effect-transistor (MESFET) using the damped electric field (DEF). The proposed structure is geometrically symmetric and compatible with common SOI CMOS fabrication processes. It has two additional oxide regions under the side gates in order to improve DC and RF characteristics of the DEF structure due to changes in the electrical potential, the electrical field distributions, and rearrangement of the charge carriers. Improvement of device performance is investigated by two-dimensional and two-carrier simulation of fundamental parameters such as breakdown voltage (VBR), drain current (ID), output power density (Pmax), transconductance (gm), gate-drain and gate-source capacitances, cut-off frequency (fT), unilateral power gain (U), current gain (h21), maximum available gain (MAG), and minimum noise figure (Fmin). The results show that proposed structure operates with higher performances in comparison with the similar conventional SOI structure.
Quantitative Evaluation of Delamination in Composites Using Lamb Waves
NASA Astrophysics Data System (ADS)
Michalcová, L.; Hron, R.
2018-03-01
Ultrasonic guided wave monitoring has become very popular in the area of structural health monitoring (SHM) of aerospace structures. Any possible type of damage must be reliably assessed. The paper deals with delamination length determination in DCB specimens using Lamb waves. An analytical equation based on the velocity dependence on variable thickness is utilized. The group velocity of the fundamental antisymmetric A0 mode rapidly changes in a particular range of the frequency-thickness product. Using the same actuation frequency the propagation velocity is different for delaminated structure. Lamb wave based delamination lengths were compared to the visually determined lengths. The method of the wave velocity determination proved to be essential. More accurate results were achieved by tracking the maximum amplitude of A0 mode than the first signal arrival. These findings are considered as the basis for the damage evaluation of complex structures.
ERIC Educational Resources Information Center
Skuk, Verena G.; Schweinberger, Stefan R.
2014-01-01
Purpose: To determine the relative importance of acoustic parameters (fundamental frequency [F0], formant frequencies [FFs], aperiodicity, and spectrum level [SL]) on voice gender perception, the authors used a novel parameter-morphing approach that, unlike spectral envelope shifting, allows the application of nonuniform scale factors to transform…
Effect of a Nitrogen Impurity on the Fundamental Raman Band of Diamond Single Crystals
NASA Astrophysics Data System (ADS)
Gusakov, G. A.; Samtsov, M. P.; Voropay, E. S.
2018-05-01
The effect of nitrogen defects in natural and synthetic diamond single crystals on the position and half-width of the fundamental Raman band was investigated. Samples containing the main types of nitrogen lattice defects at impurity contents of 1-1500 ppm were studied. The parameters of the Stokes and anti-Stokes components in Raman spectra of crystals situated in a cell with distilled water to minimize the influence of heating by the exciting laser radiation were analyzed to determine the effect of a nitrogen impurity in the diamond crystal lattice. It was shown that an increase of impurity atoms in the crystals in the studied concentration range resulted in broadening of the Raman band from 1.61 to 2.85 cm-1 and shifting of the maximum to lower frequency from 1332.65 to 1332.3 cm-1. The observed effect was directly proportional to the impurity concentration and depended on the form of the impurity incorporated into the diamond lattice. It was found that the changes in the position and half-width of the fundamental Raman band for diamond were consistent with the magnitude of crystal lattice distortions due to the presence of impurity defects and obeyed the Gruneisen law.
A quasioptical resonant-tunneling-diode oscillator operating above 200 GHz
NASA Technical Reports Server (NTRS)
Brown, E. R.; Parker, C. D.; Molvar, K. M.; Calawa, A. R.; Manfra, M. J.
1992-01-01
We have fabricated and characterized a quasioptically stabilized resonant-tunneling-diode (RTD) oscillator having attractive performance characteristics for application as a radiometric local oscillator. The fundamental frequency of the oscillator is tunable from about 200 to 215 GHz, the instantaneous linewidth is between 10 and 20 kHz, and the output power across the tuning band is about 50 micro-W. The narrow linewidth and fine tuning of the frequency are made possible by a scanning semiconfocal open cavity which acts as the high-Q resonator for the oscillator. The cavity is compact, portable, and insensitive to vibration and temperature variation. The total dc power consumption (RTD plus bias supply) is only 10 mW. The present oscillator provides the highest power obtained to date from an RTD above 200 GHz. We attribute this partly to the use of the quasioptical resonator, but primarily to the quality of the RTD. It is fabricated from the In(0.53)Ga(0.47)As/AlAs materials system, which historically has yielded the best overall resonant-tunneling characteristics of any material system. The RTD active area is 4 sq microns, and the room-temperature peak current density and peak-to-valley current ratio are 2.5x10(exp 5) A cm(exp -2) and 9, respectively. The RTD is mounted in a WR-3 standard-height rectangular waveguide and is contacted across the waveguide by a fine wire that protrudes through a via hole in a Si3N4 'honeycomb' overlayer. We estimate that the theoretical maximum frequency of oscillation of this RTD is approximately 1.1 THz, and that scaled-down versions of the same quasioptical oscillator design should operate in a fundamental mode up to frequencies of at least 500 GHz.
47 CFR 15.33 - Frequency range of radiated measurements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... radiator operates at or above 30 GHz: to the fifth harmonic of the highest fundamental frequency or to 200... kHz, up to at least the frequency shown in this paragraph: (1) If the intentional radiator operates below 10 GHz: to the tenth harmonic of the highest fundamental frequency or to 40 GHz, whichever is...
NASA Astrophysics Data System (ADS)
Henrich, Nathalie; D'Alessandro, Christophe; Doval, Boris; Castellengo, Michèle
2005-03-01
This article presents the results of glottal open-quotient measurements in the case of singing voice production. It explores the relationship between open quotient and laryngeal mechanisms, vocal intensity, and fundamental frequency. The audio and electroglottographic signals of 18 classically trained male and female singers were recorded and analyzed with regard to vocal intensity, fundamental frequency, and open quotient. Fundamental frequency and open quotient are derived from the differentiated electroglottographic signal, using the DECOM (DEgg Correlation-based Open quotient Measurement) method. As male and female phonation may differ in respect to vocal-fold vibratory properties, a distinction is made between two different glottal configurations, which are called laryngeal mechanisms: mechanism 1 (related to chest, modal, and male head register) and mechanism 2 (related to falsetto for male and head register for female). The results show that open quotient depends on the laryngeal mechanisms. It ranges from 0.3 to 0.8 in mechanism 1 and from 0.5 to 0.95 in mechanism 2. The open quotient is strongly related to vocal intensity in mechanism 1 and to fundamental frequency in mechanism 2. .
Lee, Shao-Hsuan; Fang, Tuan-Jen; Yu, Jen-Fang; Lee, Guo-She
2017-09-01
Auditory feedback can make reflexive responses on sustained vocalizations. Among them, the middle-frequency power of F0 (MFP) may provide a sensitive index to access the subtle changes in different auditory feedback conditions. Phonatory airflow temperature was obtained from 20 healthy adults at two vocal intensity ranges under four auditory feedback conditions: (1) natural auditory feedback (NO); (2) binaural speech noise masking (SN); (3) bone-conducted feedback of self-generated voice (BAF); and (4) SN and BAF simultaneously. The modulations of F0 in low-frequency (0.2 Hz-3 Hz), middle-frequency (3 Hz-8 Hz), and high-frequency (8 Hz-25 Hz) bands were acquired using power spectral analysis of F0. Acoustic and aerodynamic analyses were used to acquire vocal intensity, maximum phonation time (MPT), phonatory airflow, and MFP-based vocal efficiency (MBVE). SN and high vocal intensity decreased MFP and raised MBVE and MPT significantly. BAF showed no effect on MFP but significantly lowered MBVE. Moreover, BAF significantly increased the perception of voice feedback and the sensation of vocal effort. Altered auditory feedback significantly changed the middle-frequency modulations of F0. MFP and MBVE could well detect these subtle responses of audio-vocal feedback. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Observations concerning the generation and propagation of Type III solar bursts
NASA Technical Reports Server (NTRS)
Kellogg, P. J.
1986-01-01
A number of Type III bursts were observed during the Helios missions in which the burst exciter passed over the spacecraft, as evidenced by strong electric field fluctuations near the plasma frequency. Six of these were suitable for detailed study. Of the six events, one was ambiguous, one showed what is interpreted as a switchover from harmonic to fundamental, and the rest all generated fundamental at onset. This would be expected if both fundamental and harmonic are generated, as, at a fixed frequency, the fundamental will be generated earlier. For the event which seems to show both fundamental and harmonic emission, the frequency ratio is not exactly 2. This is explained in terms of a time delay of the fundamental, due to scattering and diffusion in the source region. A time delay of the order of 600 seconds at 1 AU and 20 kHz, and inversely proportional to frequency, is required to explain the observations. Crude estimates show that delay times at least this long may be attributed to trapping and scattering.
NASA Astrophysics Data System (ADS)
Herzog, T.; Walter, S.; Bartzsch, H.; Gittner, M.; Gloess, D.; Heuer, H.
2011-06-01
Many new materials and processes require non destructive evaluation in higher resolutions by phased array ultrasonic techniques in a frequency range up to 250 MHz. This paper presents aluminium nitride, a promising material for the use as a piezoelectric sensor material in the considered frequency range, which contains the potential for high frequency phased array application in the future. This work represents the fundamental development of piezoelectric aluminium nitride films with a thickness of up to 10 μm. We have investigated and optimized the deposition process of the aluminium nitride thin film layers regarding their piezoelectric behavior. Therefore a specific test setup and a measuring station were created to determine the piezoelectric charge constant (d33) and the electro acoustic behavior of the sensor. Single element transducers were deposited on silicon substrates with aluminium electrodes for top and bottom, using different parameters for the magnetron sputter process, like pressure and bias voltage. Afterwards acoustical measurements up to 500 MHz in pulse echo mode have been carried out and the electrical and electromechanical properties were qualified. In two different parameter sets for the sputtering process excellent piezoelectric charge constant of about 8.0 pC/N maximum were obtained.
Functional outcome of vocal fold medialization thyroplasty with a hydroxyapatite implant.
Storck, Claudio; Brockmann, Meike; Schnellmann, Elvira; Stoeckli, Sandro J; Schmid, Stephan
2007-06-01
Unilateral vocal fold paralysis can cause a persistent incomplete glottal closure during phonation, resulting in impaired voice function. The aim of this study was to evaluate functional results of medialization thyroplasty using a hydroxyapatite implant (VoCoM). Prospective observational cohort study. Between 1999 and 2003, a total of 26 patients (19 men, 7 women) undergoing medialization thyroplasty using a hydroxyapatite implant because of unilateral vocal fold paralysis were enrolled in the study. To evaluate voice function, the following parameters were measured preoperatively and postoperatively: mean fundamental frequency, mean sound pressure level, frequency and amplitude range (voice range profile), and maximum phonation time. A perceptual assessment of hoarseness was conducted using the Roughness, Breathiness, Hoarseness scale. Furthermore, the magnitude of voice related impairment of the patient's communication skills was rated on a 7-point scale. A combined parameter called the Voice Dysfunction Index (VDI) was used to rate vocal performance. All patients showed a statistically significant improvement in the VDI, in perceptual voice analysis, in maximum phonation time, and in the dynamic range of voice. One patient experienced a postoperative wound hemorrhage as a minor complication. No further complications or implant extrusions were observed. Medialization thyroplasty using a hydroxyapatite implant is a secure and efficient phonosurgical procedure. Voice quality and patient satisfaction improve significantly after treatment.
NASA Astrophysics Data System (ADS)
Mao, Zhangwen; Guo, Wei; Ji, Dianxiang; Zhang, Tianwei; Gu, Chenyi; Tang, Chao; Gu, Zhengbin; Nie*, Yuefeng; Pan, Xiaoqing
In situ reflection high-energy electron diffraction (RHEED) and its intensity oscillations are extremely important for the growth of epitaxial thin films with atomic precision. The RHEED intensity oscillations of complex oxides are, however, rather complicated and a general model is still lacking. Here, we report the unusual phase inversion and frequency doubling of RHEED intensity oscillations observed in the layer-by-layer growth of SrTiO3 using oxide molecular beam epitaxy. In contacts to the common understanding that the maximum(minimum) intensity occurs at SrO(TiO2) termination, respectively, we found that both maximum or minimum intensities can occur at SrO, TiO2, or even incomplete terminations depending on the incident angle of the electron beam, which raises a fundamental question if one can rely on the RHEED intensity oscillations to precisely control the growth of thin films. A general model including surface roughness and termination dependent mean inner potential qualitatively explains the observed phenomena, and provides the answer to the question how to prepare atomically and chemically precise surface/interfaces using RHEED oscillations for complex oxides. We thank National Basic Research Program of China (No. 11574135, 2015CB654901) and the National Thousand-Young-Talents Program.
Pattern masking: the importance of remote spatial frequencies and their phase alignment.
Huang, Pi-Chun; Maehara, Goro; May, Keith A; Hess, Robert F
2012-02-16
To assess the effects of spatial frequency and phase alignment of mask components in pattern masking, target threshold vs. mask contrast (TvC) functions for a sine-wave grating (S) target were measured for five types of mask: a sine-wave grating (S), a square-wave grating (Q), a missing fundamental square-wave grating (M), harmonic complexes consisting of phase-scrambled harmonics of a square wave (Qp), and harmonic complexes consisting of phase-scrambled harmonics of a missing fundamental square wave (Mp). Target and masks had the same fundamental frequency (0.46 cpd) and the target was added in phase with the fundamental frequency component of the mask. Under monocular viewing conditions, the strength of masking depends on phase relationships among mask spatial frequencies far removed from that of the target, at least 3 times the target frequency, only when there are common target and mask spatial frequencies. Under dichoptic viewing conditions, S and Q masks produced similar masking to each other and the phase-scrambled masks (Qp and Mp) produced less masking. The results suggest that pattern masking is spatial frequency broadband in nature and sensitive to the phase alignments of spatial components.
Nadeau, Kyle P; Rice, Tyler B; Durkin, Anthony J; Tromberg, Bruce J
2015-11-01
We present a method for spatial frequency domain data acquisition utilizing a multifrequency synthesis and extraction (MSE) method and binary square wave projection patterns. By illuminating a sample with square wave patterns, multiple spatial frequency components are simultaneously attenuated and can be extracted to determine optical property and depth information. Additionally, binary patterns are projected faster than sinusoids typically used in spatial frequency domain imaging (SFDI), allowing for short (millisecond or less) camera exposure times, and data acquisition speeds an order of magnitude or more greater than conventional SFDI. In cases where sensitivity to superficial layers or scattering is important, the fundamental component from higher frequency square wave patterns can be used. When probing deeper layers, the fundamental and harmonic components from lower frequency square wave patterns can be used. We compared optical property and depth penetration results extracted using square waves to those obtained using sinusoidal patterns on an in vivo human forearm and absorbing tube phantom, respectively. Absorption and reduced scattering coefficient values agree with conventional SFDI to within 1% using both high frequency (fundamental) and low frequency (fundamental and harmonic) spatial frequencies. Depth penetration reflectance values also agree to within 1% of conventional SFDI.
Nadeau, Kyle P.; Rice, Tyler B.; Durkin, Anthony J.; Tromberg, Bruce J.
2015-01-01
Abstract. We present a method for spatial frequency domain data acquisition utilizing a multifrequency synthesis and extraction (MSE) method and binary square wave projection patterns. By illuminating a sample with square wave patterns, multiple spatial frequency components are simultaneously attenuated and can be extracted to determine optical property and depth information. Additionally, binary patterns are projected faster than sinusoids typically used in spatial frequency domain imaging (SFDI), allowing for short (millisecond or less) camera exposure times, and data acquisition speeds an order of magnitude or more greater than conventional SFDI. In cases where sensitivity to superficial layers or scattering is important, the fundamental component from higher frequency square wave patterns can be used. When probing deeper layers, the fundamental and harmonic components from lower frequency square wave patterns can be used. We compared optical property and depth penetration results extracted using square waves to those obtained using sinusoidal patterns on an in vivo human forearm and absorbing tube phantom, respectively. Absorption and reduced scattering coefficient values agree with conventional SFDI to within 1% using both high frequency (fundamental) and low frequency (fundamental and harmonic) spatial frequencies. Depth penetration reflectance values also agree to within 1% of conventional SFDI. PMID:26524682
NASA Astrophysics Data System (ADS)
Bahlmann, N.; Gerhardt, R.; Wallenhorst, M.; Dötsch, H.
1996-10-01
Magnetic garnet films of composition (A, Bi)3(Fe, B)5 O12 are grown by liquid phase epitaxy on [111] oriented substrates of Gd3 Ga5 O12, where A=yttrium or lutetium and B=aluminum or gallium. The ferrimagnetic resonance (FMR) of in-plane magnetized films is studied by analyzing the modulation of light, which passes the film parallel to the film normal. Modulation efficiencies up to 1.8% at 2.9 GHz are observed at a wavelength of 0.633 μm. From the measured modulation intensities the precession angles of the FMR are derived. The dependence of the precession cone on the excitation frequency or on the external induction shows a foldover effect which, however, is smaller than for the FMR of perpendicularly magnetized films. Maximum precession angles up to 14° are achieved and the experiments indicate that saturation occurs. Light modulation is also observed at the first harmonic frequency, but the intensity is about 300 times weaker than at the fundamental frequency.
Oligoyne Molecular Junctions for Efficient Room Temperature Thermoelectric Power Generation.
Sadeghi, Hatef; Sangtarash, Sara; Lambert, Colin J
2015-11-11
Understanding phonon transport at a molecular scale is fundamental to the development of high-performance thermoelectric materials for the conversion of waste heat into electricity. We have studied phonon and electron transport in alkane and oligoyne chains of various lengths and find that, due to the more rigid nature of the latter, the phonon thermal conductances of oligoynes are counterintuitively lower than that of the corresponding alkanes. The thermal conductance of oligoynes decreases monotonically with increasing length, whereas the thermal conductance of alkanes initially increases with length and then decreases. This difference in behavior arises from phonon filtering by the gold electrodes and disappears when higher-Debye-frequency electrodes are used. Consequently a molecule that better transmits higher-frequency phonon modes, combined with a low-Debye-frequency electrode that filters high-energy phonons is a viable strategy for suppressing phonon transmission through the molecular junctions. The low thermal conductance of oligoynes, combined with their higher thermopower and higher electrical conductance lead to a maximum thermoelectric figure of merit of ZT = 1.4, which is several orders of magnitude higher than that of alkanes.
Driving and controlling molecular surface rotors with a terahertz electric field.
Neumann, Jan; Gottschalk, Kay E; Astumian, R Dean
2012-06-26
Great progress has been made in the design and synthesis of molecular motors and rotors. Loosely inspired by biomolecular machines such as kinesin and the FoF1 ATPsynthase, these molecules are hoped to provide elements for construction of more elaborate structures that can carry out tasks at the nanoscale corresponding to the tasks accomplished by elementary machines in the macroscopic world. Most of the molecular motors synthesized to date suffer from the drawback that they operate relatively slowly (less than kHz). Here we show by molecular dynamics studies of a diethyl sulfide rotor on a gold(111) surface that a high-frequency oscillating electric field normal to the surface can drive directed rotation at GHz frequencies. The maximum directed rotation rate is 10(10) rotations per second, significantly faster than the rotation of previously reported directional molecular rotors. Understanding the fundamental basis of directed motion of surface rotors is essential for the further development of efficient externally driven artificial rotors. Our results represent a step toward the design of a surface-bound molecular rotary motor with a tunable rotation frequency and direction.
NASA Astrophysics Data System (ADS)
Maamary, Rabih; Fertein, Eric; Fourmentin, Marc; Dewaele, Dorothée; Cazier, Fabrice; Chen, Changshui; Chen, Weidong
2017-07-01
We report on the measurements of the effective line intensities of the ν1 fundamental band of trans-nitrous acid (trans-HONO) in the infrared near 3600 cm-1 (2.78 μm). A home-made widely tunable laser spectrometer based on difference-frequency generation (DFG) was used for this study. The strengths of 28 well-resolved absorption lines of the ν1 band were determined by scaling their absorption intensities to the well referenced absorption line intensity of the ν3 band of trans-HONO around 1250 cm-1 recorded simultaneously with the help of a DFB quantum cascade laser (QCL) spectrometer. The maximum measurement uncertainty of 12% in the line intensities is mainly determined by the uncertainty announced in the referenced line intensities, while the measurement precision in frequency positions of the absorption lines is better than 6×10-4 cm-1. The cross-measurement carried out in the present work allows one to perform intensity calibration using well referenced line parameters.
Vowel selection and its effects on perturbation and nonlinear dynamic measures.
Maccallum, Julia K; Zhang, Yu; Jiang, Jack J
2011-01-01
Acoustic analysis of voice is typically conducted on recordings of sustained vowel phonation. This study applied perturbation and nonlinear dynamic analyses to the vowels /a/, /i/, and /u/ in order to determine vowel selection effects on analysis. Forty subjects (20 males and 20 females) with normal voices participated in recording. Traditional parameters of fundamental frequency, signal-to-noise ratio, percent jitter, and percent shimmer were calculated for the signals using CSpeech. Nonlinear dynamic parameters of correlation dimension and second-order entropy were also calculated. Perturbation analysis results were largely incongruous in this study and in previous research. Fundamental frequency results corroborated previous work, indicating higher fundamental frequency for /i/ and /u/ and lower fundamental frequency for /a/. Signal-to-noise ratio results showed that /i/ and /u/ have greater harmonic levels than /a/. Results of nonlinear dynamic analysis suggested that more complex activity may be evident in /a/ than in /i/ or /u/. Percent jitter and percent shimmer may not be useful for description of acoustic differences between vowels. Fundamental frequency, signal-to-noise ratio, and nonlinear dynamic parameters may be applied to characterize /a/ as having lower frequency, higher noise, and greater nonlinear components than /i/ and /u/. Copyright © 2010 S. Karger AG, Basel.
Thermal welding vs. cold knife tonsillectomy: a comparison of voice and speech.
Celebi, Saban; Yelken, Kursat; Celik, Oner; Taskin, Umit; Topak, Murat
2011-01-01
To compare acoustic, aerodynamic and perceptual voice and speech parameters in thermal welding system tonsillectomy and cold knife tonsillectomy patients in order to determine the impact of operation technique on voice and speech. Thirty tonsillectomy patients (22 children, 8 adults) participated in this study. The preferred technique was cold knife tonsillectomy in 15 patients and thermal welding system tonsillectomy in the remaining 15 patients. One week before and 1 month after surgery the following parameters were estimated: average of fundamental frequency, Jitter, Shimmer, harmonic to noise ratio, formant frequency analyses of sustained vowels. Perceptual speech analysis and aerodynamic measurements (maximum phonation time and s/z ratio) were also conducted. There was no significant difference in any of the parameters between cold knife tonsillectomy and thermal welding system tonsillectomy groups (p>0.05). When the groups were contrasted among themselves with regards to preoperative and postoperative rates, fundamental frequency was found to be significantly decreased after tonsillectomy in both of the groups (p<0.001). First formant for the vowel /a/ in the cold knife tonsillectomy group and for the vowel /i/ in the thermal welding system tonsillectomy group, second formant for the vowel /u/ in the thermal welding system tonsillectomy group and third formant for the vowel /u/ in the cold knife tonsillectomy group were found to be significantly decreased (p<0.05). The surgical technique, whether it is cold knife or thermal welding system, does not appear to affect voice and speech in tonsillectomy patients. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Song, H.; Huerta-Lopez, C. I.; Martinez-Cruzado, J. A.; Rodriguez-Lozoya, H. E.; Espinoza-Barreras, F.
2009-05-01
Results of an ongoing study to estimate the ground response upon weak and moderate earthquake excitations are presented. A reliable site characterization in terms of its soil properties and sub-soil layer configuration are parameters required in order to do a trustworthy estimation of the ground response upon dynamic loads. This study can be described by the following four steps: (1) Ambient noise measurements were collected at the study site where a bridge was under construction between the cities of Tijuana and Ensenada in Mexico. The time series were collected using a six channels recorder with an ADC converter of 16 bits within a maximum voltage range of ± 2.5 V, the recorder has an optional settings of: Butterworth/Bessel filters, gain and sampling rate. The sensors were a three orthogonal component (X, Y, Z) accelerometers with a sensitivity of 20 V/g, flat frequency response between DC to 200 Hz, and total full range of ±0.25 of g, (2) experimental H/V Spectral Ratios were computed to estimate the fundamental vibration frequency at the site, (3) using the time domain experimental H/V spectral ratios as well as the original recorded time series, the random decrement method was applied to estimate the fundamental frequency and damping of the site (system), and (4) finally the theoretical H/V spectral ratios were obtained by means of the stiffness matrix wave propagation method.. The interpretation of the obtained results was then finally compared with a geotechnical study available at the site.
NASA Astrophysics Data System (ADS)
Krasnoshchekov, Sergey V.; Schutski, Roman S.; Craig, Norman C.; Sibaev, Marat; Crittenden, Deborah L.
2018-02-01
Three dihalogenated methane derivatives (CH2F2, CH2FCl, and CH2Cl2) were used as model systems to compare and assess the accuracy of two different approaches for predicting observed fundamental frequencies: canonical operator Van Vleck vibrational perturbation theory (CVPT) and vibrational configuration interaction (VCI). For convenience and consistency, both methods employ the Watson Hamiltonian in rectilinear normal coordinates, expanding the potential energy surface (PES) as a Taylor series about equilibrium and constructing the wavefunction from a harmonic oscillator product basis. At the highest levels of theory considered here, fourth-order CVPT and VCI in a harmonic oscillator basis with up to 10 quanta of vibrational excitation in conjunction with a 4-mode representation sextic force field (SFF-4MR) computed at MP2/cc-pVTZ with replacement CCSD(T)/aug-cc-pVQZ harmonic force constants, the agreement between computed fundamentals is closer to 0.3 cm-1 on average, with a maximum difference of 1.7 cm-1. The major remaining accuracy-limiting factors are the accuracy of the underlying electronic structure model, followed by the incompleteness of the PES expansion. Nonetheless, computed and experimental fundamentals agree to within 5 cm-1, with an average difference of 2 cm-1, confirming the utility and accuracy of both theoretical models. One exception to this rule is the formally IR-inactive but weakly allowed through Coriolis-coupling H-C-H out-of-plane twisting mode of dichloromethane, whose spectrum we therefore revisit and reassign. We also investigate convergence with respect to order of CVPT, VCI excitation level, and order of PES expansion, concluding that premature truncation substantially decreases accuracy, although VCI(6)/SFF-4MR results are still of acceptable accuracy, and some error cancellation is observed with CVPT2 using a quartic force field.
Hodges-Simeon, Carolyn R; Gurven, Michael; Puts, David A; Gaulin, Steven J C
2014-07-01
Fundamental and formant frequencies influence perceived pitch and are sexually dimorphic in humans. The information content of these acoustic parameters can illuminate the forces of sexual selection shaping vocal sex differences as well as the mechanisms that ensure signal reliability. We use multiple regression to examine the relationships between somatic (height, adiposity, and strength) and acoustic (fundamental frequency [ F 0 ], formant position [ P f ], and fundamental frequency variation [ F 0 -SD]) characteristics in a sample of peripubertal Bolivian Tsimane. Results indicate that among males-but not females-strength is the strongest predictor of F 0 and P f and that F 0 and P f are independent predictors of strength when height and adiposity are controlled. These findings suggest that listeners may attend to vocal frequencies because they signal honest, nonredundant information about male strength and threat potential, which are strongly related to physical maturity and which cannot be ascertained from visual or other indicators of height or adiposity alone.
Input-output characterization of an ultrasonic testing system by digital signal analysis
NASA Technical Reports Server (NTRS)
Williams, J. H., Jr.; Lee, S. S.; Karagulle, H.
1986-01-01
Ultrasonic test system input-output characteristics were investigated by directly coupling the transmitting and receiving transducers face to face without a test specimen. Some of the fundamentals of digital signal processing were summarized. Input and output signals were digitized by using a digital oscilloscope, and the digitized data were processed in a microcomputer by using digital signal-processing techniques. The continuous-time test system was modeled as a discrete-time, linear, shift-invariant system. In estimating the unit-sample response and frequency response of the discrete-time system, it was necessary to use digital filtering to remove low-amplitude noise, which interfered with deconvolution calculations. A digital bandpass filter constructed with the assistance of a Blackman window and a rectangular time window were used. Approximations of the impulse response and the frequency response of the continuous-time test system were obtained by linearly interpolating the defining points of the unit-sample response and the frequency response of the discrete-time system. The test system behaved as a linear-phase bandpass filter in the frequency range 0.6 to 2.3 MHz. These frequencies were selected in accordance with the criterion that they were 6 dB below the maximum peak of the amplitude of the frequency response. The output of the system to various inputs was predicted and the results were compared with the corresponding measurements on the system.
Fundamentals of Acoustics. Psychoacoustics and Hearing. Acoustical Measurements
NASA Technical Reports Server (NTRS)
Begault, Durand R.; Ahumada, Al (Technical Monitor)
1997-01-01
These are 3 chapters that will appear in a book titled "Building Acoustical Design", edited by Charles Salter. They are designed to introduce the reader to fundamental concepts of acoustics, particularly as they relate to the built environment. "Fundamentals of Acoustics" reviews basic concepts of sound waveform frequency, pressure, and phase. "Psychoacoustics and Hearing" discusses the human interpretation sound pressure as loudness, particularly as a function of frequency. "Acoustic Measurements" gives a simple overview of the time and frequency weightings for sound pressure measurements that are used in acoustical work.
Approximate method for calculating free vibrations of a large-wind-turbine tower structure
NASA Technical Reports Server (NTRS)
Das, S. C.; Linscott, B. S.
1977-01-01
A set of ordinary differential equations were derived for a simplified structural dynamic lumped-mass model of a typical large-wind-turbine tower structure. Dunkerley's equation was used to arrive at a solution for the fundamental natural frequencies of the tower in bending and torsion. The ERDA-NASA 100-kW wind turbine tower structure was modeled, and the fundamental frequencies were determined by the simplified method described. The approximate fundamental natural frequencies for the tower agree within 18 percent with test data and predictions analyzed.
Objective and Subjective Aspects of Voice in Pregnancy.
Saltürk, Ziya; Kumral, Tolgar Lütfi; Bekiten, Güler; Atar, Yavuz; Ataç, Enes; Aydoğdu, İmran; Yıldırım, Güven; Kılıç, Aydın; Uyar, Yavuz
2016-01-01
This study aimed to evaluate vocal changes in pregnancy according to trimesters both objectively and subjectively. Fifty pregnant women and 15 nonpregnant women were included in the study. Eighteen of the 50 pregnant women were in the first trimester, 17 in the second trimester, and 15 in the third trimester of their pregnancies. The fundamental frequency (F0), jitter, shimmer, noise-to-harmonics ratio (NHR), and minimum and maximum pitch were determined during acoustic voice analysis. Laryngologic examination was evaluated via reflux finding score (RFS). Voice Handicap Index 10 (VHI-10) was used for subjective analysis. Maximum phonation time (MPT), VHI-10, and RFS were the parameters that differed significantly. MPT was significantly shorter in the third trimester. Acoustic analysis revealed that F0, jitter, shimmer, NHR, and minimum and maximum pitch values were not significantly different in any groups. RFS was higher in the first and third trimesters than the second trimester and control groups. VHI-10 scores were significantly higher in the third trimester. Our results showed that MPT is decreased during the third trimester, although acoustic parameters did not differ. VHI-10 results deteriorated in the third trimester significantly. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Constraints on pulsar masses from the maximum observed glitch
NASA Astrophysics Data System (ADS)
Pizzochero, P. M.; Antonelli, M.; Haskell, B.; Seveso, S.
2017-07-01
Neutron stars are unique cosmic laboratories in which fundamental physics can be probed in extreme conditions not accessible to terrestrial experiments. In particular, the precise timing of rotating magnetized neutron stars (pulsars) reveals sudden jumps in rotational frequency in these otherwise steadily spinning-down objects. These 'glitches' are thought to be due to the presence of a superfluid component in the star, and offer a unique glimpse into the interior physics of neutron stars. In this paper we propose an innovative method to constrain the mass of glitching pulsars, using observations of the maximum glitch observed in a star, together with state-of-the-art microphysical models of the pinning interaction between superfluid vortices and ions in the crust. We study the properties of a physically consistent angular momentum reservoir of pinned vorticity, and we find a general inverse relation between the size of the maximum glitch and the pulsar mass. We are then able to estimate the mass of all the observed glitchers that have displayed at least two large events. Our procedure will allow current and future observations of glitching pulsars to constrain not only the physics of glitch models but also the superfluid properties of dense hadronic matter in neutron star interiors.
Examining the cognitive demands of analogy instructions compared to explicit instructions.
Tse, Choi Yeung Andy; Wong, Andus; Whitehill, Tara; Ma, Estella; Masters, Rich
2016-10-01
In many learning domains, instructions are presented explicitly despite high cognitive demands associated with their processing. This study examined cognitive demands imposed on working memory by different types of instruction to speak with maximum pitch variation: visual analogy, verbal analogy and explicit verbal instruction. Forty participants were asked to memorise a set of 16 visual and verbal stimuli while reading aloud a Cantonese paragraph with maximum pitch variation. Instructions about how to achieve maximum pitch variation were presented via visual analogy, verbal analogy, explicit rules or no instruction. Pitch variation was assessed off-line, using standard deviation of fundamental frequency. Immediately after reading, participants recalled as many stimuli as possible. Analogy instructions resulted in significantly increased pitch variation compared to explicit instructions or no instructions. Explicit instructions resulted in poorest recall of stimuli. Visual analogy instructions resulted in significantly poorer recall of visual stimuli than verbal stimuli. The findings suggest that non-propositional instructions presented via analogy may be less cognitively demanding than instructions that are presented explicitly. Processing analogy instructions that are presented as a visual representation is likely to load primarily visuospatial components of working memory rather than phonological components. The findings are discussed with reference to speech therapy and human cognition.
Comparison of fundamental, second harmonic, and superharmonic imaging: a simulation study.
van Neer, Paul L M J; Danilouchkine, Mikhail G; Verweij, Martin D; Demi, Libertario; Voormolen, Marco M; van der Steen, Anton F W; de Jong, Nico
2011-11-01
In medical ultrasound, fundamental imaging (FI) uses the reflected echoes from the same spectral band as that of the emitted pulse. The transmission frequency determines the trade-off between penetration depth and spatial resolution. Tissue harmonic imaging (THI) employs the second harmonic of the emitted frequency band to construct images. Recently, superharmonic imaging (SHI) has been introduced, which uses the third to the fifth (super) harmonics. The harmonic level is determined by two competing phenomena: nonlinear propagation and frequency dependent attenuation. Thus, the transmission frequency yielding the optimal trade-off between the spatial resolution and the penetration depth differs for THI and SHI. This paper quantitatively compares the concepts of fundamental, second harmonic, and superharmonic echocardiography at their optimal transmission frequencies. Forward propagation is modeled using a 3D-KZK implementation and the iterative nonlinear contrast source (INCS) method. Backpropagation is assumed to be linear. Results show that the fundamental lateral beamwidth is the narrowest at focus, while the superharmonic one is narrower outside the focus. The lateral superharmonic roll-off exceeds the fundamental and second harmonic roll-off. Also, the axial resolution of SHI exceeds that of FI and THI. The far-field pulse-echo superharmonic pressure is lower than that of the fundamental and second harmonic. SHI appears suited for echocardiography and is expected to improve its image quality at the cost of a slight reduction in depth-of-field.
NASA Astrophysics Data System (ADS)
Fouquet, Meddy; Pisanski, Katarzyna; Mathevon, Nicolas; Reby, David
2016-10-01
Voice pitch (the perceptual correlate of fundamental frequency, F0) varies considerably even among individuals of the same sex and age, communicating a host of socially and evolutionarily relevant information. However, due to the almost exclusive utilization of cross-sectional designs in previous studies, it remains unknown whether these individual differences in voice pitch emerge before, during or after sexual maturation, and whether voice pitch remains stable into adulthood. Here, we measured the F0 parameters of men who were recorded once every 7 years from age 7 to 56 as they participated in the British television documentary Up Series. Linear mixed models revealed significant effects of age on all F0 parameters, wherein F0 mean, minimum, maximum and the standard deviation of F0 showed sharp pubertal decreases between age 7 and 21, yet remained remarkably stable after age 28. Critically, men's pre-pubertal F0 at age 7 strongly predicted their F0 at every subsequent adult age, explaining up to 64% of the variance in post-pubertal F0. This finding suggests that between-individual differences in voice pitch that are known to play an important role in men's reproductive success are in fact largely determined by age 7, and may therefore be linked to prenatal and/or pre-pubertal androgen exposure.
Dallaston, Katherine; Rumbach, Anna F
2016-01-01
(1) To quantify acute changes in acoustic parameters of the voices of group fitness instructors (GFIs) before and after exercise instruction. (2) To determine whether these changes are discernible perceptually by the instructor. This is a pilot prospective cohort study. Participants were six female GFIs, based in Brisbane, Australia. Participants performed a series of vocal tasks before and after instruction of a 60-minute exercise class. Data were obtained pertaining to fundamental frequency (pitch), intensity (volume), jitter, shimmer, harmonic-to-noise ratio (HNR), maximum duration of sustained phonation (MDSP), and pitch range. Additionally, self-ratings of voice quality were obtained before and after instruction. Data were analyzed using the Wilcoxon signed rank test. Significant increases (P ≤ 0.05) were found in fundamental frequency and intensity after instruction. No significant changes in jitter, shimmer, HNR, or MDSP were found before and after instruction. For the group, no significant change in self-ratings of voice quality occurred before and after instruction. Statistically significant changes in pitch and volume were found on acoustic analysis. However, these subtle changes remained within the limits of what is considered normal and representative of the participant's age and gender. Further research into the effects of exercise instruction on the voice is needed. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Multi-wavelength Yb:YAG/Nd3+:YVO4 continuous-wave microchip Raman laser.
Wang, Xiao-Lei; Dong, Jun; Wang, Xiao-Jie; Xu, Jie; Ueda, Ken-Ichi; Kaminskii, Alexander A
2016-08-01
Multi-wavelength continuous-wave (CW) Raman lasers in a laser diode pumped Yb:YAG/Nd3+:YVO4 microchip Raman laser have been demonstrated for the first time to our best knowledge. The multi-wavelength laser of the first Stokes radiation around 1.08 μm has been achieved with a Raman shift of 261 cm-1 for a-cut Nd:YVO4 crystal corresponding to the fundamental wavelength at 1.05 μm. Multi-wavelength laser operation simultaneously around 1.05 and 1.08 μm has been achieved under the incident pump power between 1.5 and 1.7 W. Multi-wavelength Raman laser with frequency separation of 1 THz around 1.08 μm has been obtained when the incident pump power is higher than 1.7 W. The maximum Raman laser output power of 260 mW at 1.08 μm is obtained and the corresponding optical-to-optical conversion efficiency is 4.2%. Elliptically polarized fundamental laser and linearly polarized Raman laser were observed in an Yb:YAG/Nd:YVO4 CW microchip Raman laser. The experimental results of linearly polarized, multi-wavelength Yb:YAG/Nd:YVO4 CW microchip Raman laser with adjustable frequency separation provide a novel approach for developing potential compact laser sources for Terahertz generation.
The Effect of Communications Medium on the Fundamental Frequency of Speech.
ERIC Educational Resources Information Center
Noll, A. Michael
1978-01-01
Describes the results of preliminary experiments to investigate the effects of communications medium (face-to-face and two-way closed circuit television) on the fundamental frequency of speakers in a dyadic communications situation. (JMF)
Inversion of high frequency surface waves with fundamental and higher modes
Xia, J.; Miller, R.D.; Park, C.B.; Tian, G.
2003-01-01
The phase velocity of Rayleigh-waves of a layered earth model is a function of frequency and four groups of earth parameters: compressional (P)-wave velocity, shear (S)-wave velocity, density, and thickness of layers. For the fundamental mode of Rayleigh waves, analysis of the Jacobian matrix for high frequencies (2-40 Hz) provides a measure of dispersion curve sensitivity to earth model parameters. S-wave velocities are the dominant influence of the four earth model parameters. This thesis is true for higher modes of high frequency Rayleigh waves as well. Our numerical modeling by analysis of the Jacobian matrix supports at least two quite exciting higher mode properties. First, for fundamental and higher mode Rayleigh wave data with the same wavelength, higher modes can "see" deeper than the fundamental mode. Second, higher mode data can increase the resolution of the inverted S-wave velocities. Real world examples show that the inversion process can be stabilized and resolution of the S-wave velocity model can be improved when simultaneously inverting the fundamental and higher mode data. ?? 2002 Elsevier Science B.V. All rights reserved.
Comparison of simulated and measured nonlinear ultrasound fields
NASA Astrophysics Data System (ADS)
Du, Yigang; Jensen, Henrik; Jensen, Jørgen Arendt
2011-03-01
In this paper results from a non-linear AS (angular spectrum) based ultrasound simulation program are compared to water-tank measurements. A circular concave transducer with a diameter of 1 inch (25.4 mm) is used as the emitting source. The measured pulses are first compared with the linear simulation program Field II, which will be used to generate the source for the AS simulation. The generated non-linear ultrasound field is measured by a hydrophone in the focal plane. The second harmonic component from the measurement is compared with the AS simulation, which is used to calculate both fundamental and second harmonic fields. The focused piston transducer with a center frequency of 5 MHz is excited by a waveform generator emitting a 6-cycle sine wave. The hydrophone is mounted in the focal plane 118 mm from the transducer. The point spread functions at the focal depth from Field II and measurements are illustrated. The FWHM (full width at half maximum) values are 1.96 mm for the measurement and 1.84 mm for the Field II simulation. The fundamental and second harmonic components of the experimental results are plotted compared with the AS simulations. The RMS (root mean square) errors of the AS simulations are 7.19% and 10.3% compared with the fundamental and second harmonic components of the measurements.
Measurements of intermediate-frequency electric and magnetic fields in households
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aerts, Sam, E-mail: sam.aerts@intec.ugent.be
Historically, assessment of human exposure to electric and magnetic fields has focused on the extremely-low-frequency (ELF) and radiofrequency (RF) ranges. However, research on the typically emitted fields in the intermediate-frequency (IF) range (300 Hz to 1 MHz) as well as potential effects of IF fields on the human body remains limited, although the range of household appliances with electrical components working in the IF range has grown significantly (e.g., induction cookers and compact fluorescent lighting). In this study, an extensive measurement survey was performed on the levels of electric and magnetic fields in the IF range typically present in residencesmore » as well as emitted by a wide range of household appliances under real-life circumstances. Using spot measurements, residential IF field levels were found to be generally low, while the use of certain appliances at close distance (20 cm) may result in a relatively high exposure. Overall, appliance emissions contained either harmonic signals, with fundamental frequencies between 6 kHz and 300 kHz, which were sometimes accompanied by regions in the IF spectrum of rather noisy, elevated field strengths, or much more capricious spectra, dominated by 50 Hz harmonics emanating far in the IF domain. The maximum peak field strengths recorded at 20 cm were 41.5 V/m and 2.7 A/m, both from induction cookers. Finally, none of the appliance emissions in the IF range exceeded the exposure summation rules recommended by the International Commission on Non-Ionizing Radiation Protection guidelines and the International Electrotechnical Commission (IEC 62233) standard at 20 cm and beyond (maximum exposure quotients EQ{sub E} 1.0 and {sub E}Q{sub H} 0.13). - Highlights: • Survey of residential electric and magnetic fields at intermediate frequencies (IF). • IF-EF and -MF emitted by 280 household appliances were characterised. • Strongest emitters were induction cookers, CFLs, LCD-TVs, and microwave ovens. • No emissions exceeded ICNIRP limits (highest exposure quotient was 1.00).« less
NASA Astrophysics Data System (ADS)
Cao, Liang; Liu, Jiepeng; Li, Jiang; Zhang, Ruizhi
2018-04-01
An extensive experimental and theoretical research study was undertaken to study the vibration serviceability of a long-span prestressed concrete floor system to be used in the lounge of a major airport. Specifically, jumping impact tests were carried out to obtain the floor's modal parameters, followed by an analysis of the distribution of peak accelerations. Running tests were also performed to capture the acceleration responses. The prestressed concrete floor was found to have a low fundamental natural frequency (≈ 8.86 Hz) corresponding to the average modal damping ratio of ≈ 2.17%. A coefficients β rp is proposed for convenient calculation of the maximum root-mean-square acceleration for running. In the theoretical analysis, the prestressed concrete floor under running excitation is treated as a two-span continuous anisotropic rectangular plate with simply-supported edges. The calculated analytical results (natural frequencies and root-mean-square acceleration) agree well with the experimental ones. The analytical approach is thus validated.
Nanoscale Subsurface Imaging via Resonant Difference-Frequency Atomic Force Ultrasonic Microscopy
NASA Technical Reports Server (NTRS)
Cantrell, Sean A.; Cantrell, John H.; Lilehei, Peter T.
2007-01-01
A novel scanning probe microscope methodology has been developed that employs an ultrasonic wave launched from the bottom of a sample while the cantilever of an atomic force microscope, driven at a frequency differing from the ultrasonic frequency by the fundamental resonance frequency of the cantilever, engages the sample top surface. The nonlinear mixing of the oscillating cantilever and the ultrasonic wave in the region defined by the cantilever tip-sample surface interaction force generates difference-frequency oscillations at the cantilever fundamental resonance. The resonance-enhanced difference-frequency signals are used to create images of embedded nanoscale features.
Maestre, H; Torregrosa, A J; Fernández-Pousa, C R; Rico, M L; Capmany, J
2008-05-01
We report a dual-wavelength continuous-wave laser at 542.4 and 546.8 nm based on an Nd(3+)-doped aperiodically poled lithium niobate crystal. Two fundamental infrared (IR) wavelengths at 1084.8 and 1093.6 nm are simultaneously oscillated and self-frequency-doubled to green. The aperiodic domain distribution patterned in the crystal allows for quasi-phase matched self-frequency-doubling of both IR fundamentals while avoiding their sum-frequency mixing.
100 years of the physics of diodes
NASA Astrophysics Data System (ADS)
Zhang, Peng; Valfells, Ágúst; Ang, L. K.; Luginsland, J. W.; Lau, Y. Y.
2017-03-01
The Child-Langmuir Law (CL), discovered a century ago, gives the maximum current that can be transported across a planar diode in the steady state. As a quintessential example of the impact of space charge shielding near a charged surface, it is central to the studies of high current diodes, such as high power microwave sources, vacuum microelectronics, electron and ion sources, and high current drivers used in high energy density physics experiments. CL remains a touchstone of fundamental sheath physics, including contemporary studies of nanoscale quantum diodes and nano gap based plasmonic devices. Its solid state analog is the Mott-Gurney law, governing the maximum charge injection in solids, such as organic materials and other dielectrics, which is important to energy devices, such as solar cells and light emitting diodes. This paper reviews the important advances in the physics of diodes since the discovery of CL, including virtual cathode formation and extension of CL to multiple dimensions, to the quantum regime, and to ultrafast processes. We review the influence of magnetic fields, multiple species in bipolar flow, electromagnetic and time dependent effects in both short pulse and high frequency THz limits, and single electron regimes. Transitions from various emission mechanisms (thermionic-, field-, and photoemission) to the space charge limited state (CL) will be addressed, especially highlighting the important simulation and experimental developments in selected contemporary areas of study. We stress the fundamental physical links between the physics of beams to limiting currents in other areas, such as low temperature plasmas, laser plasmas, and space propulsion.
rf breakdown tests of mm-wave metallic accelerating structures
Dal Forno, Massimo; Dolgashev, Valery; Bowden, Gordon; ...
2016-01-06
In this study, we explore the physics and frequency-scaling of vacuum rf breakdowns at sub-THz frequencies. We present the experimental results of rf tests performed in metallic mm-wave accelerating structures. These experiments were carried out at the facility for advanced accelerator experimental tests (FACET) at the SLAC National Accelerator Laboratory. The rf fields were excited by the FACET ultrarelativistic electron beam. We compared the performances of metal structures made with copper and stainless steel. The rf frequency of the fundamental accelerating mode, propagating in the structures at the speed of light, varies from 115 to 140 GHz. The traveling wavemore » structures are 0.1 m long and composed of 125 coupled cavities each. We determined the peak electric field and pulse length where the structures were not damaged by rf breakdowns. We calculated the electric and magnetic field correlated with the rf breakdowns using the FACET bunch parameters. The wakefields were calculated by a frequency domain method using periodic eigensolutions. Such a method takes into account wall losses and is applicable to a large variety of geometries. The maximum achieved accelerating gradient is 0.3 GV/m with a peak surface electric field of 1.5 GV/m and a pulse length of about 2.4 ns.« less
Bleeker, H J; Lewin, P A
2000-01-01
A new calibration technique for PVDF ultrasonic hydrophone probes is described. Current implementation of the technique allows determination of hydrophone frequency response between 2 and 100 MHz and is based on the comparison of theoretically predicted and experimentally determined pressure-time waveforms produced by a focused, circular source. The simulation model was derived from the time domain algorithm that solves the non linear KZK (Khokhlov-Zabolotskaya-Kuznetsov) equation describing acoustic wave propagation. The calibration technique data were experimentally verified using independent calibration procedures in the frequency range from 2 to 40 MHz using a combined time delay spectrometry and reciprocity approach or calibration data provided by the National Physical Laboratory (NPL), UK. The results of verification indicated good agreement between the results obtained using KZK and the above-mentioned independent calibration techniques from 2 to 40 MHz, with the maximum discrepancy of 18% at 30 MHz. The frequency responses obtained using different hydrophone designs, including several membrane and needle probes, are presented, and it is shown that the technique developed provides a desirable tool for independent verification of primary calibration techniques such as those based on optical interferometry. Fundamental limitations of the presented calibration method are also examined.
NASA Astrophysics Data System (ADS)
El Hussain, I. W.
2017-12-01
The current study provides a site specific deterministic seismic hazard assessment (DSHA) at the selected site for establishing the Oman Museum-Across Ages at Manah area, as a part of a comprehensive geotechnical and seismological plan to design the facilities accordingly. The DSHA first defines the seismic sources that might influence the site and assesses the maximum possible earthquake magnitude for each of them. By assuming each of these maximum earthquakes to occur at a location placing them at the closest distances to the site, the ground motion is predicted utilizing empirical ground motion prediction equations. The local site effects are performed by determining the fundamental frequency of the soft soil using HVSR technique and by estimating amplification spectra using the soil characteristics (mainly shear-wave velocity). Shear-wave velocity has been evaluated using the MASW technique. The maximum amplification value of 2.1 at spectral period 0.06 sec is observed at the ground surface, while the largest amplification value at the top of the conglomerate layer (at 5m depth) is 1.6 for a spectral period of 0.04 Sec. The maximum median 5% damped peak ground acceleration is found to be 0.263g at a spectral period of 0.1 sec. Keywords: DSHA; Site Effects; HVSR; MASW; PGA; Spectral Period
Acoustic and phonatory characterization of the Fado voice.
Mendes, Ana P; Rodrigues, Aira F; Guerreiro, David Michael
2013-09-01
Fado is a Portuguese musical genre, instrumentally accompanied by a Portuguese and an acoustic guitar. Fado singers' voice is perceptually characterized by a low pitch, hoarse, and strained voice. The present research study sketches the acoustic and phonatory profile of the Fado singers' voice. Fifteen Fado singers produced spoken and sung phonatory tasks. For the spoken voice measures, the maximum phonation time and s/z ratio of Fado singers were near the inefficient physiological threshold. Fundamental frequency was higher than that found in nonsingers and lower than that found in Western Classical singers. Jitter and shimmer mean values were higher compared with nonsingers. Harmonic-to-noise ratio (HNR) was similar to the mean values for nonsingers. For the sung voice, jitter was higher compared with Country, Musical Theater, Soul, Jazz, and Western Classical singers and lower than Pop singers. Shimmer mean values were lower than Country, Musical Theater, Pop, Soul, and Jazz singers and higher than Western Classical singers. HNR was similar for Western Classical singers. Maximum phonational frequency range of Fado singers indicated that male and female subjects had a lower range compared with Western Classical singers. Additionally, Fado singers produced vibrato, but singer's formant was rarely produced. These sung voice characteristics could be related with life habits, less/lack of singing training, or could be just a Fado voice characteristic. Copyright © 2013 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Variable frequency iteration MPPT for resonant power converters
Zhang, Qian; Bataresh, Issa; Chen, Lin
2015-06-30
A method of maximum power point tracking (MPPT) uses an MPPT algorithm to determine a switching frequency for a resonant power converter, including initializing by setting an initial boundary frequency range that is divided into initial frequency sub-ranges bounded by initial frequencies including an initial center frequency and first and second initial bounding frequencies. A first iteration includes measuring initial powers at the initial frequencies to determine a maximum power initial frequency that is used to set a first reduced frequency search range centered or bounded by the maximum power initial frequency including at least a first additional bounding frequency. A second iteration includes calculating first and second center frequencies by averaging adjacent frequent values in the first reduced frequency search range and measuring second power values at the first and second center frequencies. The switching frequency is determined from measured power values including the second power values.
Demonstrating ultrafast polarization dynamics in spin-VCSELs
NASA Astrophysics Data System (ADS)
Lindemann, Markus; Pusch, Tobias; Michalzik, Rainer; Gerhardt, Nils C.; Hofmann, Martin R.
2018-02-01
Vertical-cavity surface-emitting lasers (VCSELs) are used for short-haul optical data transmission with increasing bit rates. The optimization involves both enhanced device designs and the use of higher-order modulation formats. In order to improve the modulation bandwidth substantially, the presented work employs spin-pumped VCSELs (spin-VCSELs) and their polarization dynamics instead of relying on intensity-modulated devices. In spin-VCSELs, the polarization state of the emitted light is controllable via spin injection. By optical spin pumping a single-mode VCSEL is forced to emit light composed of both orthogonal linearly polarized fundamental modes. The frequencies of these two modes differ slightly by a value determined by the cavity birefringence. As a result, the circular polarization degree oscillates with their beat frequency, i.e., with the birefringence-induced mode splitting. We used this phenomenon to show so-called polarization oscillations, which are generated by pulsed spin injection. Their frequency represents the polarization dynamics resonance frequency and can be tuned over a wide range via the birefringence, nearly independent from any other laser parameter. In previous work we demonstrated a maximum birefringence-induced mode splitting of more than 250 GHz. In this work, compared to previous publications, we show an almost doubled polarization oscillation frequency of more than 80 GHz. Furthermore, we discuss concepts to achieve even higher values far above 100 GHz.
RCS of fundamental scatterers in the HF band by wire-grid modelling
NASA Astrophysics Data System (ADS)
Trueman, C. W.; Kubina, S. J.
To extract the maximum information from the return of a radar target such as an aircraft, the target's scattering properties must be well known. Wire grid modeling allows a detailed representation of the surface of a complex scatterer such as an aircraft, in the frequency range where the aircraft size is comparable to a wavelength. A moment method analysis determines the currents on the wires of the grid including the interactions between all parts of the structure. Wire grid models of fundamental scatterers (plates, strips, cubes, and spheres) of sizes comparable to the wavelength in the 2-30 MHz range are analyzed. The study of the radar cross section (RCS) of wire grids in comparison with measured RCS data helps to establish guidelines for building wire grid models, specifying such parameters as where to locate wires, how short the segments must be, and what radius to use. The guidelines so developed can then be applied to build wire grid models of much more complex bodies such as aircraft with much greater confidence.
Van Nguyen; Javaid, Abdul Q; Weitnauer, Mary Ann
2014-01-01
We introduce the Spectrum-averaged Harmonic Path (SHAPA) algorithm for estimation of heart rate (HR) and respiration rate (RR) with Impulse Radio Ultrawideband (IR-UWB) radar. Periodic movement of human torso caused by respiration and heart beat induces fundamental frequencies and their harmonics at the respiration and heart rates. IR-UWB enables capture of these spectral components and frequency domain processing enables a low cost implementation. Most existing methods of identifying the fundamental component either in frequency or time domain to estimate the HR and/or RR lead to significant error if the fundamental is distorted or cancelled by interference. The SHAPA algorithm (1) takes advantage of the HR harmonics, where there is less interference, and (2) exploits the information in previous spectra to achieve more reliable and robust estimation of the fundamental frequency in the spectrum under consideration. Example experimental results for HR estimation demonstrate how our algorithm eliminates errors caused by interference and produces 16% to 60% more valid estimates.
Frequency dispersion in dipolophoresis of metallodielectric Janus spheres
NASA Astrophysics Data System (ADS)
Boymelgreen, Alicia; Yossifon, Gilad; Miloh, Touvia
2013-11-01
Dipolophoresis (DIP) is an umbrella term for the two non-linear electrokinetic phenomenon of induced-charge electrophoresis (ICEP) and dielectrophoresis (DEP). It has previously been shown that this effect is responsible for the obtainment of a finite velocity by a metallodielectric (comprised of one conducting and one dielectric hemisphere) Janus spheres, even under the application of a uniform AC field. At low frequencies, this mobility is dominated by induced-charge effects, wherein the stronger induced-charge electroosmotic flow around the polarizable hemisphere propels the particle perpendicular to the electric field in the direction of its dielectric end. Surprisingly, it was observed that this motion is at a maximum for applied frequencies in the range of 1kHz beyond which the effect decays. Here we examine the effect of varying experimental conditions including electrolyte concentration and particle size on this limit. Additionally, we present for the first time an analytical solution which is capable of predicting this optimum based on our previous formulation which is uniquely valid for arbitrary electric double layer length. This work is of both fundamental and practical importance and may be used to optimize the behavior of Janus micromotors in lab-on-a-chip systems.
Ying, Liming; White, Samuel S.; Bruckbauer, Andreas; Meadows, Lisa; Korchev, Yuri E.; Klenerman, David
2004-01-01
The study of the properties of DNA under high electric fields is of both fundamental and practical interest. We have exploited the high electric fields produced locally in the tip of a nanopipette to probe the motion of double- and single-stranded 40-mer DNA, a 1-kb single-stranded DNA, and a single-nucleotide triphosphate (dCTP) just inside and outside the pipette tip at different frequencies and amplitudes of applied voltages. We used dual laser excitation and dual color detection to simultaneously follow two fluorophore-labeled DNA sequences with millisecond time resolution, significantly faster than studies to date. A strong trapping effect was observed during the negative half cycle for all DNA samples and also the dCTP. This effect was maximum below 1 Hz and decreased with higher frequency. We assign this trapping to strong dielectrophoresis due to the high electric field and electric field gradient in the pipette tip. Dielectrophoresis in electrodeless tapered nanostructures has potential applications for controlled mixing and manipulation of short lengths of DNA and other biomolecules, opening new possibilities in miniaturized biological analysis. PMID:14747337
NASA Astrophysics Data System (ADS)
Tapia, V.; González, A.; Finger, R.; Mena, F. P.; Monasterio, D.; Reyes, N.; Sánchez, M.; Bronfman, L.
2017-03-01
We present the design, implementation, and characterization of the optics of ALMA Band 1, the lowest frequency band in the most advanced radio astronomical telescope. Band 1 covers the broad frequency range from 35 to 50 GHz, with the goal of minor degradation up to 52 GHz. This is, up to now, the largest fractional bandwidth of all ALMA bands. Since the optics is the first subsystem of any receiver, low noise figure and maximum aperture efficiency are fundamental for best sensitivity. However, a conjunction of several factors (small cryostat apertures, mechanical constraints, and cost limitations) makes extremely challenging to achieve these goals. To overcome these problems, the optics presented here includes two innovative solutions, a compact optimized-profile corrugated horn and a modified Fresnel lens. The horn profile was optimized for optimum performance and easy fabrication by a single-piece manufacturing process in a lathe. In this way, manufacturability is eased when compared with traditional fabrication methods. To minimize the noise contribution of the optics, a one-step zoned lens was designed. Its parameters were carefully optimized to maximize the frequency coverage and reduce losses. The optical assembly reported here fully complies with ALMA specifications.
The maximum efficiency of nano heat engines depends on more than temperature
NASA Astrophysics Data System (ADS)
Woods, Mischa; Ng, Nelly; Wehner, Stephanie
Sadi Carnot's theorem regarding the maximum efficiency of heat engines is considered to be of fundamental importance in the theory of heat engines and thermodynamics. Here, we show that at the nano and quantum scale, this law needs to be revised in the sense that more information about the bath other than its temperature is required to decide whether maximum efficiency can be achieved. In particular, we derive new fundamental limitations of the efficiency of heat engines at the nano and quantum scale that show that the Carnot efficiency can only be achieved under special circumstances, and we derive a new maximum efficiency for others. A preprint can be found here arXiv:1506.02322 [quant-ph] Singapore's MOE Tier 3A Grant & STW, Netherlands.
The siren song of vocal fundamental frequency for romantic relationships.
Weusthoff, Sarah; Baucom, Brian R; Hahlweg, Kurt
2013-01-01
A multitude of factors contribute to why and how romantic relationships are formed as well as whether they ultimately succeed or fail. Drawing on evolutionary models of attraction and speech production as well as integrative models of relationship functioning, this review argues that paralinguistic cues (more specifically the fundamental frequency of the voice) that are initially a strong source of attraction also increase couples' risk for relationship failure. Conceptual similarities and differences between the multiple operationalizations and interpretations of vocal fundamental frequency are discussed and guidelines are presented for understanding both convergent and non-convergent findings. Implications for clinical practice and future research are discussed.
Ultra-Broad-Band Optical Parametric Amplifier or Oscillator
NASA Technical Reports Server (NTRS)
Strekalov, Dmitry; Matsko, Andrey; Savchenkov, Anatolly; Maleki, Lute
2009-01-01
A concept for an ultra-broad-band optical parametric amplifier or oscillator has emerged as a by-product of a theoretical study in fundamental quantum optics. The study was originally intended to address the question of whether the two-photon temporal correlation function of light [in particular, light produced by spontaneous parametric down conversion (SPDC)] can be considerably narrower than the inverse of the spectral width (bandwidth) of the light. The answer to the question was found to be negative. More specifically, on the basis of the universal integral relations between the quantum two-photon temporal correlation and the classical spectrum of light, it was found that the lower limit of two-photon correlation time is set approximately by the inverse of the bandwidth. The mathematical solution for the minimum two-photon correlation time also provides the minimum relative frequency dispersion of the down-converted light components; in turn, the minimum relative frequency dispersion translates to the maximum bandwidth, which is important for the design of an ultra-broad-band optical parametric oscillator or amplifier. In the study, results of an analysis of the general integral relations were applied in the case of an optically nonlinear, frequency-dispersive crystal in which SPDC produces collinear photons. Equations were found for the crystal orientation and pump wavelength, specific for each parametric-down-converting crystal, that eliminate the relative frequency dispersion of collinear degenerate (equal-frequency) signal and idler components up to the fourth order in the frequency-detuning parameter
Children's Use of the Prosodic Characteristics of Infant-Directed Speech.
ERIC Educational Resources Information Center
Weppelman, Tammy L.; Bostow, Angela; Schiffer, Ryan; Elbert-Perez, Evelyn; Newman, Rochelle S.
2003-01-01
Examined whether young children (4 years of age) show prosodic changes when speaking to infants. Measured children's word duration in infant-directed speech compared to adult-directed speech, examined amplitude variability, and examined both average fundamental frequency and fundamental frequency standard deviation. Results indicate that…
Improved design of support for large aperture space lightweight mirror
NASA Astrophysics Data System (ADS)
Wang, Chao; Ruan, Ping; Liu, Qimin
2013-08-01
In order to design a kind of rational large aperture space mirror which can adapt to the space gravity and thermal environment, by taking the choice of material, the lightweight of the mirror and the design of support into account in detail, a double-deck structure with traditional flexible hinge was designed, then the analytical mathematical model of the mirror system was established. The design adopts six supports on back. in order to avoid the constraints, mirror is connected to three middle transition pieces through six flexible hinges, and then the three transition pieces are connected to support plate through another three flexible hinges. However, the initial structure is unable to reach the expected design target and needs to be made further adjustments. By improving and optimizing the original structure, a new type of flexible hinge in the shape of the letter A is designed finally. Compared with the traditional flexible hinge structure, the new structure is simpler and has less influence on the surface figure accuracy of mirror. By using the finite element analysis method, the static and dynamic characteristics as well as the thermal characteristics of the mirror system are analyzed. Analysis results show that the maximum PV value is 37 nm and the maximum RMS value is 10.4 nm when gravity load is applied. Furthermore, the maximum PV value is 46 nm and the maximum RMS value is 10.5 nm under the load case of gravity coupled with 4℃ uniform temperature rise. The results satisfy the index of optical design. The first order natural frequency of the mirror component is 130 Hz according to the conclusion obtained by modal analytical solution, so the mirror structure has high enough fundamental frequency. And, the structural strength can meet the demand under the overload and the random vibration environment respectively. It indicates that the mirror component structure has enough dynamic, static stiffness and thermal stability, meeting the design requirements.
NASA Astrophysics Data System (ADS)
Trollinger, Valerie L.
This study investigated the relationship between acoustical measurement of singing accuracy in relationship to speech fundamental frequency, speech fundamental frequency range, age and gender in preschool-aged children. Seventy subjects from Southeastern Pennsylvania; the San Francisco Bay Area, California; and Terre Haute, Indiana, participated in the study. Speech frequency was measured by having the subjects participate in spontaneous and guided speech activities with the researcher, with 18 diverse samples extracted from each subject's recording for acoustical analysis for fundamental frequency in Hz with the CSpeech computer program. The fundamental frequencies were averaged together to derive a mean speech frequency score for each subject. Speech range was calculated by subtracting the lowest fundamental frequency produced from the highest fundamental frequency produced, resulting in a speech range measured in increments of Hz. Singing accuracy was measured by having the subjects each echo-sing six randomized patterns using the pitches Middle C, D, E, F♯, G and A (440), using the solfege syllables of Do and Re, which were recorded by a 5-year-old female model. For each subject, 18 samples of singing were recorded. All samples were analyzed by the CSpeech for fundamental frequency. For each subject, deviation scores in Hz were derived by calculating the difference between what the model sang in Hz and what the subject sang in response in Hz. Individual scores for each child consisted of an overall mean total deviation frequency, mean frequency deviations for each pattern, and mean frequency deviation for each pitch. Pearson correlations, MANOVA and ANOVA analyses, Multiple Regressions and Discriminant Analysis revealed the following findings: (1) moderate but significant (p < .001) relationships emerged between mean speech frequency and the ability to sing the pitches E, F♯, G and A in the study; (2) mean speech frequency also emerged as the strongest predictor of subjects' ability to sing the notes E and F♯; (3) mean speech frequency correlated moderately and significantly (p < .001) with sharpness and flatness of singing response accuracy in Hz; (4) speech range was the strongest predictor of singing accuracy for the pitches G and A in the study (p < .001); (5) gender emerged as a significant, but not the strongest, predictor for ability to sing the pitches in the study above C and D; (6) gender did not correlate with mean speech frequency and speech range; (7) age in months emerged as a low but significant predictor of ability to sing the lower notes (C and D) in the study; (8) age correlated significantly but negatively low (r = -.23, p < .05, two-tailed) with mean speech frequency; and (9) age did not emerge as a significant predictor of overall singing accuracy. Ancillary findings indicated that there were significant differences in singing accuracy based on geographic location by gender, and that siblings and fraternal twins in the study generally performed similarly. In addition, reliability for using the CSpeech for acoustical analysis revealed test/retest correlations of .99, with one exception at .94. Based on these results, suggestions were made concerning future research concerned with studying the use of voice in speech and how it may affect singing development, overall use in singing, and pitch-matching accuracy.
2011-01-01
Vocal production requires complex planning and coordination of respiratory, laryngeal, and vocal tract movements, which are incompletely understood in most mammals. Rats produce a variety of whistles in the ultrasonic range that are of communicative relevance and of importance as a model system, but the sources of acoustic variability were mostly unknown. The goal was to identify sources of fundamental frequency variability. Subglottal pressure, tracheal airflow, and electromyographic (EMG) data from two intrinsic laryngeal muscles were measured during 22-kHz and 50-kHz call production in awake, spontaneously behaving adult male rats. During ultrasound vocalization, subglottal pressure ranged between 0.8 and 1.9 kPa. Pressure differences between call types were not significant. The relation between fundamental frequency and subglottal pressure within call types was inconsistent. Experimental manipulations of subglottal pressure had only small effects on fundamental frequency. Tracheal airflow patterns were also inconsistently associated with frequency. Pressure and flow seem to play a small role in regulation of fundamental frequency. Muscle activity, however, is precisely regulated and very sensitive to alterations, presumably because of effects on resonance properties in the vocal tract. EMG activity of cricothyroid and thyroarytenoid muscle was tonic in calls with slow or no fundamental frequency modulations, like 22-kHz and flat 50-kHz calls. Both muscles showed brief high-amplitude, alternating bursts at rates up to 150 Hz during production of frequency-modulated 50-kHz calls. A differentiated and fine regulation of intrinsic laryngeal muscles is critical for normal ultrasound vocalization. Many features of the laryngeal muscle activation pattern during ultrasound vocalization in rats are shared with other mammals. PMID:21832032
Effects of Phonetic Context on Relative Fundamental Frequency
ERIC Educational Resources Information Center
Lien, Yu-An S.; Gattuccio, Caitlin I.; Stepp, Cara E.
2014-01-01
Purpose: The effect of phonetic context on relative fundamental frequency (RFF) was examined, in order to develop stimuli sets with minimal within-speaker variability that can be implemented in future clinical protocols. Method: Sixteen speakers with healthy voices produced RFF stimuli. Uniform utterances consisted of 3 repetitions of the same…
Cross-Linguistic Differences in Bilinguals' Fundamental Frequency Ranges
ERIC Educational Resources Information Center
Ordin, Mikhail; Mennen, Ineke
2017-01-01
Purpose: We investigated cross-linguistic differences in fundamental frequency range (FFR) in Welsh-English bilingual speech. This is the first study that reports gender-specific behavior in switching FFRs across languages in bilingual speech. Method: FFR was conceptualized as a behavioral pattern using measures of span (range of fundamental…
N'djin, William Apoutou; Burtnyk, Mathieu; Bronskill, Michael; Chopra, Rajiv
2012-01-01
Transurethral ultrasound therapy uses real-time magnetic resonance (MR) temperature feedback to enable the 3D control of thermal therapy accurately in a region within the prostate. Previous canine studies showed the feasibility of this method in vivo. The aim of this study was to reduce the procedure time, while maintaining targeting accuracy, by investigating new combinations of treatment parameters. Simulations and validation experiments in gel phantoms were used, with a collection of nine 3D realistic target prostate boundaries obtained from previous preclinical studies, where multi-slice MR images were acquired with the transurethral device in place. Acoustic power and rotation rate were varied based on temperature feedback at the prostate boundary. Maximum acoustic power and rotation rate were optimised interdependently, as a function of prostate radius and transducer operating frequency. The concept of dual frequency transducers was studied, using the fundamental frequency or the third harmonic component depending on the prostate radius. Numerical modelling enabled assessment of the effects of several acoustic parameters on treatment outcomes. The range of treatable prostate radii extended with increasing power, and tended to narrow with decreasing frequency. Reducing the frequency from 8 MHz to 4 MHz or increasing the surface acoustic power from 10 to 20 W/cm(2) led to treatment times shorter by up to 50% under appropriate conditions. A dual frequency configuration of 4/12 MHz with 20 W/cm(2) ultrasound intensity exposure can treat entire prostates up to 40 cm(3) in volume within 30 min. The interdependence between power and frequency may, however, require integrating multi-parametric functions in the controller for future optimisations.
47 CFR 90.377 - Frequencies available; maximum EIRP and antenna height, and priority communications.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Frequencies available; maximum EIRP and antenna...; maximum EIRP and antenna height, and priority communications. (a) Licensees shall transmit only the power... maximum EIRP permitted for an RSU with an antenna height not exceeding 8 meters above the roadway bed...
47 CFR 90.377 - Frequencies available; maximum EIRP and antenna height, and priority communications.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Frequencies available; maximum EIRP and antenna...; maximum EIRP and antenna height, and priority communications. (a) Licensees shall transmit only the power... maximum EIRP permitted for an RSU with an antenna height not exceeding 8 meters above the roadway bed...
47 CFR 90.377 - Frequencies available; maximum EIRP and antenna height, and priority communications.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false Frequencies available; maximum EIRP and antenna...; maximum EIRP and antenna height, and priority communications. (a) Licensees shall transmit only the power... maximum EIRP permitted for an RSU with an antenna height not exceeding 8 meters above the roadway bed...
47 CFR 90.377 - Frequencies available; maximum EIRP and antenna height, and priority communications.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Frequencies available; maximum EIRP and antenna...; maximum EIRP and antenna height, and priority communications. (a) Licensees shall transmit only the power... maximum EIRP permitted for an RSU with an antenna height not exceeding 8 meters above the roadway bed...
Harmonics generation near ion-cyclotron frequency of ECR plasma
NASA Astrophysics Data System (ADS)
Chowdhury, Satyajit; Biswas, Subir; Chakrabarti, Nikhil; Pal, Rabindranath
2017-10-01
Wave excitation at different frequency regime is employed in the MaPLE device ECR plasma for varied excitation amplitude. At very low amplitude excitation, mainly fundamental frequency mode of the exciter signal frequency comes into play. With the increase in amplitude of applied perturbation, harmonics are generated and dominant over the fundamental frequency mode. There is a fixed critical amplitude of exciter to yield the harmonics and is independent of applied frequency. Observed harmonics and the main frequency mode has propagation characteristics and are discussed here. Exact mode number and propagation nature are also tried to measure in the experiment. Detailed experimental results will be presented. Department of Science and Technology of Government of India (Project No. SB/S2/HEP-005/2014).
How we hear what is not there: A neural mechanism for the missing fundamental illusion
NASA Astrophysics Data System (ADS)
Chialvo, Dante R.
2003-12-01
How the brain estimates the pitch of a complex sound remains unsolved. Complex sounds are composed of more than one tone. When two tones occur together, a third lower pitched tone is often heard. This is referred to as the "missing fundamental illusion" because the perceived pitch is a frequency (fundamental) for which there is no actual source vibration. This phenomenon exemplifies a larger variety of problems related to how pitch is extracted from complex tones, music and speech, and thus has been extensively used to test theories of pitch perception. A noisy nonlinear process is presented here as a candidate neural mechanism to explain the majority of reported phenomenology and provide specific quantitative predictions. The two basic premises of this model are as follows: (I) The individual tones composing the complex tones add linearly producing peaks of constructive interference whose amplitude is always insufficient to fire the neuron (II): The spike threshold is reached only with noise, which naturally selects the maximum constructive interferences. The spacing of these maxima, and consequently the spikes, occurs at a rate identical to the perceived pitch for the complex tone. Comparison with psychophysical and physiological data reveals a remarkable quantitative agreement not dependent on adjustable parameters. In addition, results from numerical simulations across different models are consistent, suggesting relevance to other sensory modalities.
Bai, Neng; Xia, Cen; Li, Guifang
2012-10-08
We propose and experimentally demonstrate single-carrier adaptive frequency-domain equalization (SC-FDE) to mitigate multipath interference (MPI) for the transmission of the fundamental mode in a few-mode fiber. The FDE approach reduces computational complexity significantly compared to the time-domain equalization (TDE) approach while maintaining the same performance. Both FDE and TDE methods are evaluated by simulating long-haul fundamental-mode transmission using a few-mode fiber. For the fundamental mode operation, the required tap length of the equalizer depends on the differential mode group delay (DMGD) of a single span rather than DMGD of the entire link.
The Impact of Vocal Hyperfunction on Relative Fundamental Frequency during Voicing Offset and Onset
ERIC Educational Resources Information Center
Stepp, Cara E.; Hillman, Robert E.; Heaton, James T.
2010-01-01
Purpose: This study tested the hypothesis that individuals with vocal hyperfunction would show decreases in relative fundamental frequency (RFF) surrounding a voiceless consonant. Method: This retrospective study of 2 clinical databases used speech samples from 15 control participants and women with hyperfunction-related voice disorders: 82 prior…
Voice Relative Fundamental Frequency via Neck-Skin Acceleration in Individuals with Voice Disorders
ERIC Educational Resources Information Center
Lien, Yu-An S.; Calabrese, Carolyn R.; Michener, Carolyn M.; Murray, Elizabeth Heller; Van Stan, Jarrad H.; Mehta, Daryush D.; Hillman, Robert E.; Noordzij, J. Pieter; Stepp, Cara E.
2015-01-01
Purpose: This study investigated the use of neck-skin acceleration for relative fundamental frequency (RFF) analysis. Method: Forty individuals with voice disorders associated with vocal hyperfunction and 20 age- and sex-matched control participants were recorded with a subglottal neck-surface accelerometer and a microphone while producing speech…
Effect of Fundamental Frequency on Judgments of Electrolaryngeal Speech
ERIC Educational Resources Information Center
Nagle, Kathy F.; Eadie, Tanya L.; Wright, Derek R.; Sumida, Yumi A.
2012-01-01
Purpose: To determine (a) the effect of fundamental frequency (f0) on speech intelligibility, acceptability, and perceived gender in electrolaryngeal (EL) speakers, and (b) the effect of known gender on speech acceptability in EL speakers. Method: A 2-part study was conducted. In Part 1, 34 healthy adults provided speech recordings using…
ERIC Educational Resources Information Center
Murray, Elizabeth S. Heller; Lien, Yu-An S.; Van Stan, Jarrad H.; Mehta, Daryush D.; Hillman, Robert E.; Noordzij, J. Pieter; Stepp, Cara E.
2017-01-01
Purpose: The purpose of this article is to examine the ability of an acoustic measure, relative fundamental frequency (RFF), to distinguish between two subtypes of vocal hyperfunction (VH): phonotraumatic (PVH) and non-phonotraumatic (NPVH). Method: RFF values were compared among control individuals with typical voices (N = 49), individuals with…
Code of Federal Regulations, 2010 CFR
2010-10-01
... limited to intentional radiators used as field disturbance sensors, excluding perimeter protection systems. (b) The field strength of emissions from intentional radiators operated within these frequency bands shall comply with the following: Fundamental frequency (MHz) Field strength of fundamental (millivolts...
Zourmand, Alireza; Ting, Hua-Nong; Mirhassani, Seyed Mostafa
2013-03-01
Speech is one of the prevalent communication mediums for humans. Identifying the gender of a child speaker based on his/her speech is crucial in telecommunication and speech therapy. This article investigates the use of fundamental and formant frequencies from sustained vowel phonation to distinguish the gender of Malay children aged between 7 and 12 years. The Euclidean minimum distance and multilayer perceptron were used to classify the gender of 360 Malay children based on different combinations of fundamental and formant frequencies (F0, F1, F2, and F3). The Euclidean minimum distance with normalized frequency data achieved a classification accuracy of 79.44%, which was higher than that of the nonnormalized frequency data. Age-dependent modeling was used to improve the accuracy of gender classification. The Euclidean distance method obtained 84.17% based on the optimal classification accuracy for all age groups. The accuracy was further increased to 99.81% using multilayer perceptron based on mel-frequency cepstral coefficients. Copyright © 2013 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Skeletal maturation, fundamental motor skills and motor coordination in children 7-10 years.
Freitas, Duarte L; Lausen, Berthold; Maia, José António; Lefevre, Johan; Gouveia, Élvio Rúbio; Thomis, Martine; Antunes, António Manuel; Claessens, Albrecht L; Beunen, Gaston; Malina, Robert M
2015-01-01
Relationships between skeletal maturation and fundamental motor skills and gross motor coordination were evaluated in 429 children (213 boys and 216 girls) 7-10 years. Skeletal age was assessed (Tanner-Whitehouse 2 method), and stature, body mass, motor coordination (Körperkoordinations Test für Kinder, KTK) and fundamental motor skills (Test of Gross Motor Development, TGMD-2) were measured. Relationships among chronological age, skeletal age (expressed as the standardised residual of skeletal age on chronological age) and body size and fundamental motor skills and motor coordination were analysed with hierarchical multiple regression. Standardised residual of skeletal age on chronological age interacting with stature and body mass explained a maximum of 7.0% of the variance in fundamental motor skills and motor coordination over that attributed to body size per se. Standardised residual of skeletal age on chronological age alone accounted for a maximum of 9.0% of variance in fundamental motor skills, and motor coordination over that attributed to body size per se and interactions between standardised residual of skeletal age on chronological age and body size. In conclusion, skeletal age alone or interacting with body size has a negligible influence on fundamental motor skills and motor coordination in children 7-10 years.
Vocal impact of a prolonged reading task in dysphonic versus normophonic female teachers.
Remacle, Angélique; Morsomme, Dominique; Berrué, Elise; Finck, Camille
2012-11-01
This study evaluates the effect of a 2-hour reading task between 70 and 75 dB(A) in 16 normophonic and 16 dysphonic female teachers with vocal nodules. Objective measurements (acoustic analysis, voice range measurements, and aerodynamic measurements) and subjective self-ratings were collected before and every 30 minutes during the reading to determine the voice evolution in both groups. Fundamental frequency, lowest frequency, highest frequency (F-High), highest intensity, and intensity range increase through the reading, whereas shimmer decreases. Maximum phonation time decreases after 30 minutes. Estimated subglottal pressure (ESP) and sound pressure level increase during the first hour. Afterward, ESP decreases. Self-ratings worsen through time. When comparing the normophonic and the dysphonic teachers, self-ratings reveal more complaints in the dysphonic group. Few differences in objective measurements are found between both groups: normophonic teachers show lower ESP, higher F-High, and greater frequency range. Frequency modifications from acoustic analysis and voice range measurements suggest an increased laryngeal tension during vocal load, while subjects perceive a worsening of voice. Aerodynamic parameters depict first a deterioration of voice efficiency and then an adaptation to the prolonged reading. The comparison between both groups shows a discrepancy between objective measurements and self-ratings, suggesting that both approaches are necessary to have a complete view of vocal load effects. Surprisingly, both groups behave similarly through vocal load, without more or quicker deterioration of voice in the dysphonic group. Copyright © 2012 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Picosecond-precision multichannel autonomous time and frequency counter
NASA Astrophysics Data System (ADS)
Szplet, R.; Kwiatkowski, P.; RóŻyc, K.; Jachna, Z.; Sondej, T.
2017-12-01
This paper presents the design, implementation, and test results of a multichannel time interval and frequency counter developed as a desktop instrument. The counter contains four main functional modules for (1) performing precise measurements, (2) controlling and fast data processing, (3) low-noise power suppling, and (4) supplying a stable reference clock (optional rubidium standard). A fundamental for the counter, the time interval measurement is based on time stamping combined with a period counting and in-period two-stage time interpolation that allows us to achieve wide measurement range (above 1 h), high precision (even better than 4.5 ps), and high measurement speed (up to 91.2 × 106 timestamps/s). The frequency is measured up to 3.0 GHz with the use of the reciprocal method. Wide functionality of the counter includes also the evaluation of frequency stability of clocks and oscillators (Allan deviation) and phase variation (time interval error, maximum time interval error, time deviation). The 8-channel measurement module is based on a field programmable gate array device, while the control unit involves a microcontroller with a high performance ARM-Cortex core. An efficient and user-friendly control of the counter is provided either locally, through the built-in keypad or/and color touch panel, or remotely, with the aid of USB, Ethernet, RS232C, or RS485 interfaces.
Picosecond-precision multichannel autonomous time and frequency counter.
Szplet, R; Kwiatkowski, P; Różyc, K; Jachna, Z; Sondej, T
2017-12-01
This paper presents the design, implementation, and test results of a multichannel time interval and frequency counter developed as a desktop instrument. The counter contains four main functional modules for (1) performing precise measurements, (2) controlling and fast data processing, (3) low-noise power suppling, and (4) supplying a stable reference clock (optional rubidium standard). A fundamental for the counter, the time interval measurement is based on time stamping combined with a period counting and in-period two-stage time interpolation that allows us to achieve wide measurement range (above 1 h), high precision (even better than 4.5 ps), and high measurement speed (up to 91.2 × 10 6 timestamps/s). The frequency is measured up to 3.0 GHz with the use of the reciprocal method. Wide functionality of the counter includes also the evaluation of frequency stability of clocks and oscillators (Allan deviation) and phase variation (time interval error, maximum time interval error, time deviation). The 8-channel measurement module is based on a field programmable gate array device, while the control unit involves a microcontroller with a high performance ARM-Cortex core. An efficient and user-friendly control of the counter is provided either locally, through the built-in keypad or/and color touch panel, or remotely, with the aid of USB, Ethernet, RS232C, or RS485 interfaces.
Elbouchikhi, Elhoussin; Choqueuse, Vincent; Benbouzid, Mohamed
2016-07-01
Condition monitoring of electric drives is of paramount importance since it contributes to enhance the system reliability and availability. Moreover, the knowledge about the fault mode behavior is extremely important in order to improve system protection and fault-tolerant control. Fault detection and diagnosis in squirrel cage induction machines based on motor current signature analysis (MCSA) has been widely investigated. Several high resolution spectral estimation techniques have been developed and used to detect induction machine abnormal operating conditions. This paper focuses on the application of MCSA for the detection of abnormal mechanical conditions that may lead to induction machines failure. In fact, this paper is devoted to the detection of single-point defects in bearings based on parametric spectral estimation. A multi-dimensional MUSIC (MD MUSIC) algorithm has been developed for bearing faults detection based on bearing faults characteristic frequencies. This method has been used to estimate the fundamental frequency and the fault related frequency. Then, an amplitude estimator of the fault characteristic frequencies has been proposed and fault indicator has been derived for fault severity measurement. The proposed bearing faults detection approach is assessed using simulated stator currents data, issued from a coupled electromagnetic circuits approach for air-gap eccentricity emulating bearing faults. Then, experimental data are used for validation purposes. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.
Keçeli, Murat; Hirata, So; Yagi, Kiyoshi
2010-07-21
The frequencies of the infrared- and/or Raman-active (k=0) vibrations of polyethylene and polyacetylene are computed by taking account of the anharmonicity in the potential energy surfaces (PESs) and the resulting phonon-phonon couplings explicitly. The electronic part of the calculations is based on Gaussian-basis-set crystalline orbital theory at the Hartree-Fock and second-order Møller-Plesset (MP2) perturbation levels, providing one-, two-, and/or three-dimensional slices of the PES (namely, using the so-called n-mode coupling approximation with n=3), which are in turn expanded in the fourth-order Taylor series with respect to the normal coordinates. The vibrational part uses the vibrational self-consistent field, vibrational MP2, and vibrational truncated configuration-interaction (VCI) methods within the Gamma approximation, which amounts to including only k=0 phonons. It is shown that accounting for both electron correlation and anharmonicity is essential in achieving good agreement (the mean and maximum absolute deviations less than 50 and 90 cm(-1), respectively, for polyethylene and polyacetylene) between computed and observed frequencies. The corresponding values for the calculations including only one of such effects are in excess of 120 and 300 cm(-1), respectively. The VCI calculations also reproduce semiquantitatively the frequency separation and intensity ratio of the Fermi doublet involving the nu(2)(0) fundamental and nu(8)(pi) first overtone in polyethylene.
CEO stabilized frequency comb from a 1-μm Kerr-lens mode-locked bulk Yb:CYA laser.
Yu, Zijiao; Han, Hainian; Xie, Yang; Peng, Yingnan; Xu, Xiaodong; Wei, Zhiyi
2016-02-08
We report the first Kerr-lens mode-locked (KLM) bulk frequency comb in the 1-μm spectral regime. The fundamental KLM Yb:CYA laser is pumped by a low-noise, high-bright 976-nm fiber laser and typically provides 250-mW output power and 57-fs pulse duration. Only 58-mW output pulses were launched into a 1.3-m photonic crystal fiber (PCF) for one octave-spanning supercontinuum generation. Using a simplified collinear f-2f interferometer, the free-running carrier-envelope offset (CEO) frequency was measured to be 42-dB signal-to-noise ratio (SNR) for a 100-kHz resolution and 9.6-kHz full width at half maximum (FWHM) under a 100-Hz resolution. A long-term CEO control at 23 MHz was ultimately realized by feeding the phase error signal to the pump power of the oscillator. The integrated phase noise (IPN) of the locked CEO was measured to be 316 mrad with an integrated range from 1 Hz to 10 MHz. The standard deviation and Allan deviation for more than 4-hour recording are 1.6 mHz and 5.6 × 10(-18) (for 1-s gate time), respectively. This is, to the best of our knowledge, the best stability achieved among the 1-μm solid-state frequency combs.
Lattice Mechanical Properties of Noble and Transition Metals
NASA Astrophysics Data System (ADS)
Baria, J. K.
2004-04-01
A model pseudopotential depending on an effective core radius but otherwise parameter free is used to study the interatomic interactions, phonon dispersion curves (in q and r-space analysis), phonon density of states, mode Grüneisen parameters, dynamical elastic constants ( C 11, C 12 and C 44), bulk modulus ( B), shear modulus ( C'), deviation from Cauchy relation ( C 12 C 44), Poisson’s ratio ( σ), Young’s modulus ( Y), behavior of phonon frequencies in the elastic limit independent of the direction ( Y 1), limiting value in the [110] direction ( Y 2), degree of elastic anisotropy ( A), maximum frequency ω max, mean frequency < ω>, < ω 2>1/2=(< ω>/< ω -1>)1/2, fundamental frequency < ω 2>, and propagation velocities of the elastic constants in Cu, Ag, Au, Ni, Pd, and Pt. The contribution of s-like electrons is calculated in the second-order perturbation theory for the model potential while that of d-like electrons is taken into account by introducing repulsive short-range Born-Mayer like term. Very recently proposed screening function due to Sarkar et al. has been used to obtain the screened form factor. The theoretical results are compared with experimental findings wherever possible. A good agreement between theoretical investigations and experimental findings has proved the ability of our model potential for predicting a large number of physical properties of transition metals.
Freddie Mercury-acoustic analysis of speaking fundamental frequency, vibrato, and subharmonics.
Herbst, Christian T; Hertegard, Stellan; Zangger-Borch, Daniel; Lindestad, Per-Åke
2017-04-01
Freddie Mercury was one of the twentieth century's best-known singers of commercial contemporary music. This study presents an acoustical analysis of his voice production and singing style, based on perceptual and quantitative analysis of publicly available sound recordings. Analysis of six interviews revealed a median speaking fundamental frequency of 117.3 Hz, which is typically found for a baritone voice. Analysis of voice tracks isolated from full band recordings suggested that the singing voice range was 37 semitones within the pitch range of F#2 (about 92.2 Hz) to G5 (about 784 Hz). Evidence for higher phonations up to a fundamental frequency of 1,347 Hz was not deemed reliable. Analysis of 240 sustained notes from 21 a-cappella recordings revealed a surprisingly high mean fundamental frequency modulation rate (vibrato) of 7.0 Hz, reaching the range of vocal tremor. Quantitative analysis utilizing a newly introduced parameter to assess the regularity of vocal vibrato corroborated its perceptually irregular nature, suggesting that vibrato (ir)regularity is a distinctive feature of the singing voice. Imitation of subharmonic phonation samples by a professional rock singer, documented by endoscopic high-speed video at 4,132 frames per second, revealed a 3:1 frequency locked vibratory pattern of vocal folds and ventricular folds.
Piezoelectric Lead Zirconate Titanate (PZT) Ring Shaped Contour-Mode MEMS Resonators
NASA Astrophysics Data System (ADS)
Kasambe, P. V.; Asgaonkar, V. V.; Bangera, A. D.; Lokre, A. S.; Rathod, S. S.; Bhoir, D. V.
2018-02-01
Flexibility in setting fundamental frequency of resonator independent of its motional resistance is one of the desired criteria in micro-electromechanical (MEMS) resonator design. It is observed that ring-shaped piezoelectric contour-mode MEMS resonators satisfy this design criterion than in case of rectangular plate MEMS resonators. Also ring-shaped contour-mode piezoelectric MEMS resonator has an advantage that its fundamental frequency is defined by in-plane dimensions, but they show variation of fundamental frequency with different Platinum (Pt) thickness referred as change in ratio of fNEW /fO . This paper presents the effects of variation in geometrical parameters and change in piezoelectric material on the resonant frequencies of Platinum piezoelectric-Aluminium ring-shaped contour-mode MEMS resonators and its electrical parameters. The proposed structure with Lead Zirconate Titanate (PZT) as the piezoelectric material was observed to be a piezoelectric material with minimal change in fundamental resonant frequency due to Platinum thickness variation. This structure was also found to exhibit extremely low motional resistance of 0.03 Ω as compared to the 31-35 Ω range obtained when using AlN as the piezoelectric material. CoventorWare 10 is used for the design, simulation and corresponding analysis of resonators which is Finite Element Method (FEM) analysis and design tool for MEMS devices.
Lee, André; Voget, Jakob; Furuya, Shinichi; Morise, Masanori; Altenmüller, Eckart
2016-05-01
Task-specific tremor in musicians is an involuntary oscillating muscular activity mostly of the hand or the embouchure, which predominantly occurs while playing the instrument. In contrast to arm or hand tremors, which have been examined and objectified based on movement kinematics and muscular activity, embouchure tremor has not yet been investigated. To quantify and describe embouchure tremor we analysed sound production and investigated the fluctuation of the time-varying fundamental frequency of sustained notes. A comparison between patients with embouchure tremor and healthy controls showed a significantly higher fluctuation of the fundamental frequency for the patients in the high pitch with a tremor frequency range between 3 and 8 Hz. The present findings firstly provide further information about a scarcely described movement disorder and secondly further evaluate a new quantification method for embouchure tremor, which has recently been established for embouchure dystonia.
ERIC Educational Resources Information Center
Rana, K. P. S.; Kumar, Vineet; Mendiratta, Jatin
2017-01-01
One of the most elementary concepts in freshmen Electrical Engineering subject comprises the Resistance-Inductance-Capacitance (RLC) circuit fundamentals, that is, their time and frequency domain responses. For a beginner, generally, it is difficult to understand and appreciate the step and the frequency responses, particularly the resonance. This…
ERIC Educational Resources Information Center
Roy, Nelson; Fetrow, Rebecca A.; Merrill, Ray M.; Dromey, Christopher
2016-01-01
Purpose: Vocal hyperfunction, related to abnormal laryngeal muscle activity, is considered the proximal cause of primary muscle tension dysphonia (pMTD). Relative fundamental frequency (RFF) has been proposed as an objective acoustic marker of vocal hyperfunction. This study examined (a) the ability of RFF to track changes in vocal hyperfunction…
ERIC Educational Resources Information Center
McKenna, Victoria S.; Heller Murray, Elizabeth S.; Lien, Yu-An S.; Stepp, Cara E.
2016-01-01
Purpose: This study examined the relationship between the acoustic measure relative fundamental frequency (RFF) and a kinematic estimate of laryngeal stiffness. Method: Twelve healthy adults (mean age = 22.7 years, SD = 4.4; 10 women, 2 men) produced repetitions of /ifi/ while varying their vocal effort during simultaneous acoustic and video…
ERIC Educational Resources Information Center
Lien, Yu-An S.; Michener, Carolyn M.; Eadie, Tanya L.; Stepp, Cara E.
2015-01-01
Purpose: The acoustic measure relative fundamental frequency (RFF) was investigated as a potential objective measure to track variations in vocal effort within and across individuals. Method: Twelve speakers with healthy voices created purposeful modulations in their vocal effort during speech tasks. RFF and an aerodynamic measure of vocal effort,…
ERIC Educational Resources Information Center
Stepp, Cara E.; Merchant, Gabrielle R.; Heaton, James T.; Hillman, Robert E.
2011-01-01
Purpose: The purpose of this study was to determine whether the relative fundamental frequency (RFF) surrounding a voiceless consonant in patients with hyperfunctionally related voice disorders would normalize after a successful course of voice therapy. Method: Pre- and posttherapy measurements of RFF were compared in 16 subjects undergoing voice…
NASA Astrophysics Data System (ADS)
Foltynowicz, Aleksandra; Picqué, Nathalie; Ye, Jun
2018-05-01
Frequency combs are becoming enabling tools for many applications in science and technology, beyond the original purpose of frequency metrology of simple atoms. The precisely evenly spaced narrow lines of a laser frequency comb inspire intriguing approaches to molecular spectroscopy, designed and implemented by a growing community of scientists. Frequency-comb spectroscopy advances the frontiers of molecular physics across the entire electro-magnetic spectrum. Used as frequency rulers, frequency combs enable absolute frequency measurements and precise line shape studies of molecular transitions, for e.g. tests of fundamental physics and improved determination of fundamental constants. As light sources interrogating the molecular samples, they dramatically improve the resolution, precision, sensitivity and acquisition time of broad spectral-bandwidth spectroscopy and open up new opportunities and applications at the leading edge of molecular spectroscopy and sensing.
Design and optimization of a modal- independent linear ultrasonic motor.
Zhou, Shengli; Yao, Zhiyuan
2014-03-01
To simplify the design of the linear ultrasonic motor (LUSM) and improve its output performance, a method of modal decoupling for LUSMs is proposed in this paper. The specific embodiment of this method is decoupling of the traditional LUSM stator's complex vibration into two simple vibrations, with each vibration implemented by one vibrator. Because the two vibrators are designed independently, their frequencies can be tuned independently and frequency consistency is easy to achieve. Thus, the method can simplify the design of the LUSM. Based on this method, a prototype modal- independent LUSM is designed and fabricated. The motor reaches its maximum thrust force of 47 N, maximum unloaded speed of 0.43 m/s, and maximum power of 7.85 W at applied voltage of 200 Vpp. The motor's structure is then optimized by controlling the difference between the two vibrators' resonance frequencies to reach larger output speed, thrust, and power. The optimized results show that when the frequency difference is 73 Hz, the output force, speed, and power reach their maximum values. At the input voltage of 200 Vpp, the motor reaches its maximum thrust force of 64.2 N, maximum unloaded speed of 0.76 m/s, maximum power of 17.4 W, maximum thrust-weight ratio of 23.7, and maximum efficiency of 39.6%.
Nearfield acoustic holography. I - Theory of generalized holography and the development of NAH
NASA Technical Reports Server (NTRS)
Maynard, J. D.; Williams, E. G.; Lee, Y.
1985-01-01
Because its underlying principles are so fundamental, holography has been studied and applied in many areas of science. Recently, a technique has been developed which takes the maximum advantage of the fundamental principles and extracts much more information from a hologram than is customarily associated with such a measurement. In this paper the fundamental principles of holography are reviewed, and a sound radiation measurement system, called nearfield acoustic holography (NAH), which fully exploits the fundamental principles, is described.
Maxillary arch dimensions associated with acoustic parameters in prepubertal children.
Hamdan, Abdul-Latif; Khandakji, Mohannad; Macari, Anthony Tannous
2018-04-18
To evaluate the association between maxillary arch dimensions and fundamental frequency and formants of voice in prepubertal subjects. Thirty-five consecutive prepubertal patients seeking orthodontic treatment were recruited (mean age = 11.41 ± 1.46 years; range, 8 to 13.7 years). Participants with a history of respiratory infection, laryngeal manipulation, dysphonia, congenital facial malformations, or history of orthodontic treatment were excluded. Dental measurements included maxillary arch length, perimeter, depth, and width. Voice parameters comprising fundamental frequency (f0_sustained), Habitual pitch (f0_count), Jitter, Shimmer, and different formant frequencies (F1, F2, F3, and F4) were measured using acoustic analysis prior to initiation of any orthodontic treatment. Pearson's correlation coefficients were used to measure the strength of associations between different dental and voice parameters. Multiple linear regressions were computed for the predictions of different dental measurements. Arch width and arch depth had moderate significant negative correlations with f0 ( r = -0.52; P = .001 and r = -0.39; P = .022, respectively) and with habitual frequency ( r = -0.51; P = .0014 and r = -0.34; P = .04, respectively). Arch depth and arch length were significantly correlated with formant F3 and formant F4, respectively. Predictors of arch depth included frequencies of F3 vowels, with a significant regression equation ( P-value < .001; R 2 = 0.49). Similarly, fundamental frequency f0 and frequencies of formant F3 vowels were predictors of arch width, with a significant regression equation ( P-value < .001; R 2 = 0.37). There is a significant association between arch dimensions, particularly arch length and depth, and voice parameters. The formant most predictive of arch depth and width is the third formant, along with fundamental frequency of voice.
The stability of H/V spectral ratios from noise measurements in Armutlu Peninsula (Turkey)
NASA Astrophysics Data System (ADS)
Livaoǧlu, Hamdullah; Irmak, T. Serkan; Caka, Deniz; Yavuz, Evrim; Lühr, B. G.; Woith, H.; Tunç, B.; Baris, S.
2016-04-01
The horizontal to vertical spectral ratio (H/V) method has been successfully using in order to estimate the fundamental resonance frequency of the sedimentary cover, its thickness and amplification factor since at least 3 decades. There are numerous studies have been carried out on the stability of the H/V spectral ratios. Almost all studies showed that fundamental frequency is stable even measurements are repeated at different times. From this point of view, the results will show us an approach whether the stations are suitable for accurate estimate of earthquake studies and engineering purposes or not. Also we want to see if any effects of the amplification factor changing on the seismograms for Armutlu Seismic Network (ARNET) even though seismic stations are established far away from cultural noise and located on hard rock sites. It has been selected one hour recorded data of all stations during the most stationary times. The amplification and resonant frequency variations of H/V ratio were calculated to investigate temporal stability in time. There is a total harmony in fundamental frequencies values and H/V spectral ratio values in time-lagged periods. Some stations shows secondary minor peaks in high frequency band due to a shallow formation effect or cultural noises around. In the east side of the area ILYS station shows amplitude peak in lower fundamental frequency band from expected. This could compose a high amplification in lower frequencies and so that yield less reliable results in local earthquakes studies. By the experimental results from ambient noise analysis, it could be worked up for relocation of one station.
Pulsations of the High-Amplitude δ Scuti star YZ Bootis
NASA Astrophysics Data System (ADS)
Yang, Tao-Zhi; Esamdin, Ali; Fu, Jian-Ning; Niu, Hu-Biao; Feng, Guo-Jie; Song, Fang-Fang; Liu, Jin-Zhong; Ma, Lu
2018-01-01
We present a study on pulsations of the high-amplitude δ Scuti star YZ Boo based on photometric observations in Johnson V and R bands with both the Nanshan 1-m telescope of Xinjiang AstronomicalObservatory (XAO) and the Xinglong 85-cmtelescope of NationalAstronomical Observatories, Chinese Academy of Sciences (NAOC). Fourier analysis of the light curves reveals the fundamental radial mode and its five harmonics, with the fourth and fifth being newly detected. Thirty-nine new times of maximum light are determined from the light curves, and combined with those in the literature, we construct the O ‑ C diagram, derive a new ephemeris and determine a new value for the updated period of 0.104091579(2). In addition, the O ‑ C diagram reveals an increasing rate of period change for YZ Boo. Theoretical models are calculated and constrained with the observationally determined parameters of YZ Boo. The mass and age of YZ Boo are hence derived as M = 1.61±0.05 M ⊙ and age = (1.44±0.14)×109 yr, respectively.With both the frequency of the fundamental radial mode and the rate of period change, YZ Boo is located at the post main sequence stage.
Yuan, Jinhui; Kang, Zhe; Li, Feng; Zhang, Xianting; Mei, Chao; Zhou, Guiyao; Sang, Xinzhu; Wu, Qiang; Yan, Binbin; Zhou, Xian; Zhong, Kangping; Wang, Kuiru; Yu, Chongxiu; Farrell, Gerald; Lu, Chao; Tam, Hwa Yaw; Wai, P K A
2017-09-15
In this Letter, we demonstrate experimentally for the first time, to the best of our knowledge, discrete ultraviolet (UV) wavelength generation by cascaded intermodal FWM when femtosecond pump pulses at 800 nm are launched into the deeply normal dispersion region of the fundamental guided mode of a multimode photonic crystal fiber (MPCF). For pump pulses at average input powers of P av =450, 550, and 650 mW, the first anti-Stokes waves are generated at the visible wavelength of 538.1 nm through intermodal phase matching between the fundamental and second-order guided mode of the MPCF. The first anti-Stokes waves generated then serve as the secondary pump for the next intermodal FWM process. The second anti-Stokes waves in the form of the third-order guided mode are generated at the UV wavelength of 375.8 nm. The maximum output power is above 10 mW for P av =650 mW. We also confirm that the influences of fiber bending and intermodal walk-offs on the cascaded intermodal FWM-based frequency conversion process are negligible.
Borch, D Zangger; Sundberg, Johan
2011-09-01
This investigation aims at describing voice function of four nonclassical styles of singing, Rock, Pop, Soul, and Swedish Dance Band. A male singer, professionally experienced in performing in these genres, sang representative tunes, both with their original lyrics and on the syllable /pae/. In addition, he sang tones in a triad pattern ranging from the pitch Bb2 to the pitch C4 on the syllable /pae/ in pressed and neutral phonation. An expert panel was successful in classifying the samples, thus suggesting that the samples were representative of the various styles. Subglottal pressure was estimated from oral pressure during the occlusion for the consonant [p]. Flow glottograms were obtained from inverse filtering. The four lowest formant frequencies differed between the styles. The mean of the subglottal pressure and the mean of the normalized amplitude quotient (NAQ), that is, the ratio between the flow pulse amplitude and the product of period and maximum flow declination rate, were plotted against the mean of fundamental frequency. In these graphs, Rock and Swedish Dance Band assumed opposite extreme positions with respect to subglottal pressure and mean phonation frequency, whereas the mean NAQ values differed less between the styles. Copyright © 2011 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
A C-band 55% PAE high gain two-stage power amplifier based on AlGaN/GaN HEMT
NASA Astrophysics Data System (ADS)
Zheng, Jia-Xin; Ma, Xiao-Hua; Lu, Yang; Zhao, Bo-Chao; Zhang, Hong-He; Zhang, Meng; Cao, Meng-Yi; Hao, Yue
2015-10-01
A C-band high efficiency and high gain two-stage power amplifier based on AlGaN/GaN high electron mobility transistor (HEMT) is designed and measured in this paper. The input and output impedances for the optimum power-added efficiency (PAE) are determined at the fundamental and 2nd harmonic frequency (f0 and 2f0). The harmonic manipulation networks are designed both in the driver stage and the power stage which manipulate the second harmonic to a very low level within the operating frequency band. Then the inter-stage matching network and the output power combining network are calculated to achieve a low insertion loss. So the PAE and the power gain is greatly improved. In an operation frequency range of 5.4 GHz-5.8 GHz in CW mode, the amplifier delivers a maximum output power of 18.62 W, with a PAE of 55.15% and an associated power gain of 28.7 dB, which is an outstanding performance. Project supported by the National Key Basic Research Program of China (Grant No. 2011CBA00606), Program for New Century Excellent Talents in University, China (Grant No. NCET-12-0915), and the National Natural Science Foundation of China (Grant No. 61334002).
Vaxenburg, Roman; Wyche, Isis; Svoboda, Karel; Efros, Alexander L.
2018-01-01
Vibrations are important cues for tactile perception across species. Whisker-based sensation in mice is a powerful model system for investigating mechanisms of tactile perception. However, the role vibration plays in whisker-based sensation remains unsettled, in part due to difficulties in modeling the vibration of whiskers. Here, we develop an analytical approach to calculate the vibrations of whiskers striking objects. We use this approach to quantify vibration forces during active whisker touch at a range of locations along the whisker. The frequency and amplitude of vibrations evoked by contact are strongly dependent on the position of contact along the whisker. The magnitude of vibrational shear force and bending moment is comparable to quasi-static forces. The fundamental vibration frequencies are in a detectable range for mechanoreceptor properties and below the maximum spike rates of primary sensory afferents. These results suggest two dynamic cues exist that rodents can use for object localization: vibration frequency and comparison of vibrational to quasi-static force magnitude. These complement the use of quasi-static force angle as a distance cue, particularly for touches close to the follicle, where whiskers are stiff and force angles hardly change during touch. Our approach also provides a general solution to calculation of whisker vibrations in other sensing tasks. PMID:29584719
Unsteady aerodynamics of reverse flow dynamic stall on an oscillating blade section
NASA Astrophysics Data System (ADS)
Lind, Andrew H.; Jones, Anya R.
2016-07-01
Wind tunnel experiments were performed on a sinusoidally oscillating NACA 0012 blade section in reverse flow. Time-resolved particle image velocimetry and unsteady surface pressure measurements were used to characterize the evolution of reverse flow dynamic stall and its sensitivity to pitch and flow parameters. The effects of a sharp aerodynamic leading edge on the fundamental flow physics of reverse flow dynamic stall are explored in depth. Reynolds number was varied up to Re = 5 × 105, reduced frequency was varied up to k = 0.511, mean pitch angle was varied up to 15∘, and two pitch amplitudes of 5∘ and 10∘ were studied. It was found that reverse flow dynamic stall of the NACA 0012 airfoil is weakly sensitive to the Reynolds numbers tested due to flow separation at the sharp aerodynamic leading edge. Reduced frequency strongly affects the onset and persistence of dynamic stall vortices. The type of dynamic stall observed (i.e., number of vortex structures) increases with a decrease in reduced frequency and increase in maximum pitch angle. The characterization and parameter sensitivity of reverse flow dynamic stall given in the present work will enable the development of a physics-based analytical model of this unsteady aerodynamic phenomenon.
Pressure and high-Tc superconductivity in sulfur hydrides.
Gor'kov, Lev P; Kresin, Vladimir Z
2016-05-11
The paper discusses fundamentals of record-TC superconductivity discovered under high pressure in sulfur hydride. The rapid increase of TC with pressure in the vicinity of Pcr ≈ 123GPa is interpreted as the fingerprint of a first-order structural transition. Based on the cubic symmetry of the high-TC phase, it is argued that the lower-TC phase has a different periodicity, possibly related to an instability with a commensurate structural vector. In addition to the acoustic branches, the phonon spectrum of H3S contains hydrogen modes with much higher frequencies. Because of the complex spectrum, usual methods of calculating TC are here inapplicable. A modified approach is formulated and shown to provide realistic values for TC and to determine the relative contributions of optical and acoustic branches. The isotope effect (change of TC upon Deuterium for Hydrogen substitution) originates from high frequency phonons and differs in the two phases. The decrease of TC following its maximum in the high-TC phase is a sign of intermixing with pairing at hole-like pockets which arise in the energy spectrum of the cubic phase at the structural transition. On-pockets pairing leads to the appearance of a second gap and is remarkable for its non-adiabatic regime: hydrogen mode frequencies are comparable to the Fermi energy.
Matching initial torque with different stimulation parameters influences skeletal muscle fatigue.
Bickel, C Scott; Gregory, Chris M; Azuero, Andres
2012-01-01
A fundamental barrier to using electrical stimulation in the clinical setting is an inability to maintain torque production secondary to muscle fatigue. Electrical stimulation parameters are manipulated to influence muscle torque production, and they may also influence fatigability during repetitive stimulation. Our purpose was to determine the response of the quadriceps femoris to three different fatigue protocols using the same initial torque obtained by altering stimulator parameter settings. Participants underwent fatigue protocols in which either pulse frequency (lowHz), pulse duration (lowPD), or voltage (lowV) was manipulated to obtain an initial torque that equaled 25% of maximum voluntary isometric contraction. Muscle soreness was reported on a visual analog scale 48 h after each fatigue test. The lowHz protocol resulted in the least fatigue (25% +/- 14%); the lowPD (50% +/- 13%) and lowV (48% +/- 14%) protocols had similar levels of fatigue. The lowHz protocol resulted in significantly less muscle soreness than the higher frequency protocols. Stimulation protocols that use a lower frequency coupled with long pulse durations and high voltages result in lesser amounts of muscle fatigue and perceived soreness. The identification of optimal stimulation patterns to maximize muscle performance will reduce the effect of muscle fatigue and potentially improve clinical efficacy.
ERIC Educational Resources Information Center
Carrell, Thomas D.
This study investigated the contributions of fundamental frequency, formant spacing, and glottal waveform to talker identification. The first two experiments focused on the effect of glottal waveform in the perception of talker identity. Subjects in the first experiment, 30 undergraduate students enrolled in an introductory psychology course,…
ERIC Educational Resources Information Center
Barcroft, Joe; Sommers, Mitchell S.
2014-01-01
Previous studies (Barcroft & Sommers, 2005; Sommers & Barcroft, 2007) have demonstrated that variability in talker, speaking style, and speaking rate positively affect second language vocabulary learning, whereas variability in overall amplitude and fundamental frequency (F0) do not, at least for native English speakers. Sommers and…
USDA-ARS?s Scientific Manuscript database
In this chapter, definitions of dielectric properties, or permittivity, of materials and a brief discussion of the fundamental principles governing their behavior with respect to influencing factors are presented. The basic physics of the influence of frequency of the electric fields and temperatur...
Code of Federal Regulations, 2010 CFR
2010-10-01
... emissions from intentional radiators operated within these frequency bands shall comply with the following: Fundamental frequency Field strength of fundamental (millivolts/meter) Field strength of harmonics (microvolts..., point-to-point operation as referred to in this paragraph shall be limited to systems employing a fixed...
Bloch, Yuval; Aviram, Shai; Neeman, Ronnie; Braw, Yoram; Nitzan, Uriel; Maoz, Hagai; Mimouni-Bloch, Aviva
2015-01-01
Prosody production is highly personalized, related to both the emotional and cognitive state of the speaker and to the task being performed. Fundamental frequency (F main) is a central measurable feature of prosody, associated with having an attention deficit hyperactive disorder (ADHD). Since methylphenidate is an effective therapy for ADHD, we hypothesized that it will affect the fundamental frequency of ADHD patients. The answers of 32 adult ADHD patients were recorded while performing two computerized tasks (cognitive and emotional). Evaluations were performed at baseline and an hour after patients received methylphenidate. A significant effect of methylphenidate was observed on the fundamental frequency, as opposed to other parameters, of prosody. This change was evident while patients performed a cognitive, as opposed to an emotional, task. This change was seen in the 14 female ADHD patients but not in the 18 male ADHD patients. The fundamental frequency while performing a cognitive task without methylphenidate was not different in the female ADHD group, from 22 female controls. This pilot study supports prosodic changes as possible objective and accessible dynamic biological marker of treatment responses specifically in female ADHD.
NASA Astrophysics Data System (ADS)
Shi, Wei; Fang, Qiang; Fan, Jingli; Cui, Xuelong; Zhang, Zhuo; Li, Jinhui; Zhou, Guoqing
2017-02-01
We report a single frequency, linearly polarized, near diffraction-limited, pulsed laser source at 775 nm by frequency doubling a single frequency nanosecond pulsed all fiber based master oscillator-power amplifier, seeded by a fiber coupled semiconductor DFB laser diode at 1550 nm. The laser diode was driven by a pulsed laser driver to generate 5 ns laser pulses at 260 Hz repetition rate with 50 pJ pulse energy. The pulse energy was boosted to 200 μJ using two stages of core-pumped fiber amplifiers and two stages of cladding-pumped fiber amplifiers. The multi-stage synchronous pulse pumping technique was adopted in the four stages of fiber amplifiers to mitigate the ASE. The frequency doubling is implemented in a single pass configuration using a periodically poled lithium niobate (PPLN) crystal. The crystal is 3 mm long, 1.4 mm wide, 1 mm thick, with a 19.36 μm domain period chosen for quasi-phase matching at 33°C. It was AR coated at both 1550 nm and 775 nm. The maximum pulse energy of 97 μJ was achieved when 189 μJ fundamental laser was launched. The corresponding conversion efficiency is about 51.3%. The pulse duration was measured to be 4.8 ns. So the peak power of the generated 775 nm laser pulses reached 20 kW. To the best of our knowledge, this is the first demonstration of a 100 μJ-level, tens of kilowatts-peak-power-level single frequency linearly polarized 775 nm laser based on the frequency doubling of the fiber lasers.
Achieving Optimal Quantum Acceleration of Frequency Estimation Using Adaptive Coherent Control.
Naghiloo, M; Jordan, A N; Murch, K W
2017-11-03
Precision measurements of frequency are critical to accurate time keeping and are fundamentally limited by quantum measurement uncertainties. While for time-independent quantum Hamiltonians the uncertainty of any parameter scales at best as 1/T, where T is the duration of the experiment, recent theoretical works have predicted that explicitly time-dependent Hamiltonians can yield a 1/T^{2} scaling of the uncertainty for an oscillation frequency. This quantum acceleration in precision requires coherent control, which is generally adaptive. We experimentally realize this quantum improvement in frequency sensitivity with superconducting circuits, using a single transmon qubit. With optimal control pulses, the theoretically ideal frequency precision scaling is reached for times shorter than the decoherence time. This result demonstrates a fundamental quantum advantage for frequency estimation.
Variations of the Milankovitch frequencies in time
NASA Technical Reports Server (NTRS)
Loutre, Marie-France; Berger, A.
1992-01-01
The sensitivity of the amplitudes and frequencies in the development of the Earth's orbital and rotational elements involved in the astronomical theory of paleoclimates (eccentricity, obliquity, and climate precession), to the Earth-Moon distance and consequently to the length of the day and to the dynamical ellipticity of the Earth has been discussed for the last billions of years. The shortening of the Earth-Moon distance and of the length of the day, as well as the lengthening of the dynamical ellipticity of the Earth back in time induce a shortening of the fundamental astronomical periods for precession and obliquity. At the same time, the amplitudes of the different terms in the development of the obliquity are undergoing a relative enlargement of about 50 percent at 2 x 10(exp 9) yr BP but the independent term is increasing very weakly (less than 0.1 percent). In other words, the value of the obliquity, which lies within a range of 21.7 to 24.9 deg over the Quarternary was restricted to a range of 22.5 to 24.1 deg at 2 x 10(exp 9) yr BP. On the other hand, the amplitudes in the development of the climatic precession do not change. Moreover, these changes in the frequencies and amplitudes for both obliquity and climatic precession are larger for longer period terms. Finally, the periods in the eccentricity development are not influenced by the variation of the lunar distance. But the motion of the solar system, especially of the inner planets, was shown to be chaotic. It means that it is impossible to compute the exact motion of the planets over more than about 100 Myr, and the fundamental frequencies of the systems are not fixed quantities, but are slowly varying with time. As long as we consider the most important terms, the maximum deviation from the present-day value of the 19-kyr precessional period due to the chaotic motion of the solar system only does not reach more than a few tens of years around 80 Myr BP. Therefore the shortening of the obliquity and climatic precession periods is mostly driven by the change in the lunar distance and the consequent variations in the dynamical ellipticity of the Earth's angular speed. At first sight, the deviation in the period for the eccentricity can be neglected, as the chaotic behavior of the solar system implies a relative change of the main periods by less than 0.2 percent, 1.4 percent, and 1.9 percent respectively, this maximum change being achieved around 80 Myr BP. This implies, in particular, that the eccentricity periods for Quarternary climate studies may be considered more or less constant for pre-Quaternay times and equal to their Quaternary values.
Efficient methods for joint estimation of multiple fundamental frequencies in music signals
NASA Astrophysics Data System (ADS)
Pertusa, Antonio; Iñesta, José M.
2012-12-01
This study presents efficient techniques for multiple fundamental frequency estimation in music signals. The proposed methodology can infer harmonic patterns from a mixture considering interactions with other sources and evaluate them in a joint estimation scheme. For this purpose, a set of fundamental frequency candidates are first selected at each frame, and several hypothetical combinations of them are generated. Combinations are independently evaluated, and the most likely is selected taking into account the intensity and spectral smoothness of its inferred patterns. The method is extended considering adjacent frames in order to smooth the detection in time, and a pitch tracking stage is finally performed to increase the temporal coherence. The proposed algorithms were evaluated in MIREX contests yielding state of the art results with a very low computational burden.
NASA Astrophysics Data System (ADS)
Massa, Marco; Barani, Simone; Lovati, Sara
2014-06-01
The paper presents an extensive review of topographic effects in seismology taking into account the knowledge of 40 yr of scientific literature. An overview of topographic effects based on experimental observations and numerical modelling is presented with the aim of highlighting meaning and causes of these phenomena as well as possible correlations between site response (fundamental frequency, amplification level) and geometrical (width and shape ratio of a relief) parameters. After a thorough summary of topographic effects, the paper focuses on five Italian sites whose seismic response is potentially affected by local morphology, as already evidenced by previous studies. In this study, seismic data recorded at these sites are analysed computing directional spectral ratios both in terms of horizontal to vertical spectral ratios (HVSRs) and, wherever possible, in terms of standard spectral ratios (SSRs). The analysis lead to the conclusion that wavefield tends to be polarized along a direction perpendicular to the main axis of a topographic irregularity, direction along which ground motion amplification is maximum. The final section of the article compares and contrasts different spectral ratio techniques in order to examine their effectiveness and reliability in detecting topographic effects. The examples discussed in the paper show that site responses based on HVSRs rather than SSR measurements could lead to misinterpretation of ground response results, both as concerns the definition of the site fundamental frequency and amplification level. Results and findings of this work will be used as starting point to discuss the influence of topographic effects on ground motion prediction equations and regulations for design. These topics will be discussed in the companion article.
Changes After Voice Therapy in Acoustic Voice Analysis of Chinese Patients With Voice Disorders.
Lu, Dan; Chen, Fei; Yang, Hui; Yu, Rong; Zhou, Qi; Zhang, Xinyuan; Ren, Jia; Zheng, Yitao; Zhang, Xiaoyan; Zou, Jian; Wang, Haiyang; Liu, Jun
2018-05-01
This study aimed to evaluate the effects of voice therapy on patients with voice disorders by comparing the acoustic parameter changes before and after treatment. This is a retrospective study. Forty-five female patients with early-stage vocal nodules or polyps, postoperative patients, and patients with chronic laryngitis were divided into three subgroups. Videostroboscopic, acoustic analysis (fundamental frequency, jitter, shimmer, mean harmonics-to-noise ratio), and maximum phonation time (MPT) were measured before and after treatment. Fifty healthy female volunteers were the control group. After treatment, 24.4% of nodules or polyps had decreased in size, 11.1% of patients with chronic laryngitis and postoperative patients had reduced edema, and the mucosal wave of vocal folds had different degrees of recovery in postoperative patients. All acoustic analysis values and MPT in the patient group were statistically worse than in the control group, except for fundamental frequency before treatment (P > 0.05). After treatment, the acoustic analysis and MPT values were improved. However, the jitter, mean harmonics-to-noise ratio, and MPT values in the patient group were still worse after voice therapy than in the control group (P < 0.05). Most of acoustic analysis values can be useful as a complementary tool in diagnosis and assessment of voice disorders; however, it is not recommended to use a single parameter to assess voice quality. Voice therapy can improve voice quality in patients with voice disorders, but a period longer than 8 weeks is recommended for these patients. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
The use of fundamental frequency for lexical segmentation in listeners with cochlear implants.
Spitzer, Stephanie; Liss, Julie; Spahr, Tony; Dorman, Michael; Lansford, Kaitlin
2009-06-01
Fundamental frequency (F0) variation is one of a number of acoustic cues normal hearing listeners use for guiding lexical segmentation of degraded speech. This study examined whether F0 contour facilitates lexical segmentation by listeners fitted with cochlear implants (CIs). Lexical boundary error patterns elicited under unaltered and flattened F0 conditions were compared across three groups: listeners with conventional CI, listeners with CI and preserved low-frequency acoustic hearing, and normal hearing listeners subjected to CI simulations. Results indicate that all groups attended to syllabic stress cues to guide lexical segmentation, and that F0 contours facilitated performance for listeners with low-frequency hearing.
An evaluation of voice stress analysis techniques in a simulated AWACS environment
NASA Astrophysics Data System (ADS)
Jones, William A., Jr.
1990-08-01
The purpose was to determine if voice analysis algorithms are an effective measure of stress resulting from high workload. Fundamental frequency, frequency jitter, and amplitude shimmer algorithms were employed to measure the effects of stress in crewmember communications data in simulated AWACS mission scenarios. Two independent workload measures were used to identify levels of stress: a predictor model developed by the simulation author based upon scenario generated stimulus events; and the duration of communication for each weapons director, representative of the individual's response to the induced stress. Between eight and eleven speech samples were analyzed for each of the sixteen Air Force officers who participated in the study. Results identified fundamental frequency and frequency jitter as statistically significant vocal indicators of stress, while amplitude shimmer showed no signs of any significant relationship with workload or stress. Consistent with previous research, the frequency algorithm was identified as the most reliable measure. However, the results did not reveal a sensitive discrimination measure between levels of stress, but rather, did distinguish between the presence or absence of stress. The results illustrate a significant relationship between fundamental frequency and the effects of stress and also a significant inverse relationship with jitter, though less dramatic.
A Mechanism for Frequency Modulation in Songbirds Shared with Humans
Margoliash, Daniel
2013-01-01
In most animals that vocalize, control of fundamental frequency is a key element for effective communication. In humans, subglottal pressure controls vocal intensity but also influences fundamental frequency during phonation. Given the underlying similarities in the biomechanical mechanisms of vocalization in humans and songbirds, songbirds offer an attractive opportunity to study frequency modulation by pressure. Here, we present a novel technique for dynamic control of subsyringeal pressure in zebra finches. By regulating the opening of a custom-built fast valve connected to the air sac system, we achieved partial or total silencing of specific syllables, and could modify syllabic acoustics through more complex manipulations of air sac pressure. We also observed that more nuanced pressure variations over a limited interval during production of a syllable concomitantly affected the frequency of that syllable segment. These results can be explained in terms of a mathematical model for phonation that incorporates a nonlinear description for the vocal source capable of generating the observed frequency modulations induced by pressure variations. We conclude that the observed interaction between pressure and frequency was a feature of the source, not a result of feedback control. Our results indicate that, beyond regulating phonation or its absence, regulation of pressure is important for control of fundamental frequencies of vocalizations. Thus, although there are separate brainstem pathways for syringeal and respiratory control of song production, both can affect airflow and frequency. We hypothesize that the control of pressure and frequency is combined holistically at higher levels of the vocalization pathways. PMID:23825417
A mechanism for frequency modulation in songbirds shared with humans.
Amador, Ana; Margoliash, Daniel
2013-07-03
In most animals that vocalize, control of fundamental frequency is a key element for effective communication. In humans, subglottal pressure controls vocal intensity but also influences fundamental frequency during phonation. Given the underlying similarities in the biomechanical mechanisms of vocalization in humans and songbirds, songbirds offer an attractive opportunity to study frequency modulation by pressure. Here, we present a novel technique for dynamic control of subsyringeal pressure in zebra finches. By regulating the opening of a custom-built fast valve connected to the air sac system, we achieved partial or total silencing of specific syllables, and could modify syllabic acoustics through more complex manipulations of air sac pressure. We also observed that more nuanced pressure variations over a limited interval during production of a syllable concomitantly affected the frequency of that syllable segment. These results can be explained in terms of a mathematical model for phonation that incorporates a nonlinear description for the vocal source capable of generating the observed frequency modulations induced by pressure variations. We conclude that the observed interaction between pressure and frequency was a feature of the source, not a result of feedback control. Our results indicate that, beyond regulating phonation or its absence, regulation of pressure is important for control of fundamental frequencies of vocalizations. Thus, although there are separate brainstem pathways for syringeal and respiratory control of song production, both can affect airflow and frequency. We hypothesize that the control of pressure and frequency is combined holistically at higher levels of the vocalization pathways.
NASA Astrophysics Data System (ADS)
Rahman, M. F. A.; Dhar, A.; Das, S.; Dutta, D.; Paul, M. C.; Rusdi, M. F. M.; Latiff, A. A.; Dimyati, K.; Harun, S. W.
2018-07-01
We demonstrate a Q-switched all-fiber laser operating at 2-μm region by adding a piece of 8 cm long holmium doped fiber (HDF) as a fiber saturable absorber (SA) in Thulium doped fiber laser (TDFL) ring cavity. Doping of Ho ions into yttria-alumina silica glass was done through conventional Modified Chemical Vapor Deposition (MCVD) technique in conjunction with solution doping process. The fabricated HDF has a linear absorption of 3 dB with a core diameter and a numerical aperture of 10 μm and 0.18, respectively. A self-started Q-switching operation begins at 418 mW pump level and continually dominant until 564 mW pump level. As the pump power increases, stable pulse train presence from 30.61 kHz to 38.89 kHz while the pulse width reduces from 3.18 μs to 2.27 μs. Both maximum output power and maximum peak power are obtained at 5.05 mW and 57.2 mW, respectively, while the maximum pulse energy is calculated to be 129 nJ. The signal-to-noise ratio (SNR) of the fundamental frequency is 50 dB. Our work may contribute to the discovery of stable, robust, and economic SA for pulse fiber laser generation at 2-μm region.
NASA Technical Reports Server (NTRS)
Lorenzo, C. F.
1974-01-01
Tests were conducted to determine the dynamic characteristics of the Centaur/RL-10 oxygen and hydrogen feedlines. The fundamental-mode resonant frequencies were determined by applying power spectral methods to noise-generated data from hot firings of the RL-10 engine. The effect of net positive suction pressure of the main feed pumps on resonant frequency characteristics was determined to be a straight-line relation. Power spectral methods were also used to determine the dynamic characteristics of the boost pumps.
Hyperfine-resolved transition frequency list of fundamental vibration bands of H35Cl and H37Cl
NASA Astrophysics Data System (ADS)
Iwakuni, Kana; Sera, Hideyuki; Abe, Masashi; Sasada, Hiroyuki
2014-12-01
Sub-Doppler resolution spectroscopy of the fundamental vibration bands of H35Cl and H37Cl has been carried out from 87.1 to 89.9 THz. We have determined the absolute transition frequencies of the hyperfine-resolved R(0) to R(4) transitions with a typical uncertainty of 10 kHz. We have also yielded six molecular constants for each isotopomer in the vibrational excited state, which reproduce the determined frequencies with a standard deviation of about 10 kHz.
Correlation Plenoptic Imaging.
D'Angelo, Milena; Pepe, Francesco V; Garuccio, Augusto; Scarcelli, Giuliano
2016-06-03
Plenoptic imaging is a promising optical modality that simultaneously captures the location and the propagation direction of light in order to enable three-dimensional imaging in a single shot. However, in standard plenoptic imaging systems, the maximum spatial and angular resolutions are fundamentally linked; thereby, the maximum achievable depth of field is inversely proportional to the spatial resolution. We propose to take advantage of the second-order correlation properties of light to overcome this fundamental limitation. In this Letter, we demonstrate that the correlation in both momentum and position of chaotic light leads to the enhanced refocusing power of correlation plenoptic imaging with respect to standard plenoptic imaging.
NASA Astrophysics Data System (ADS)
D'Angelo, Milena; Pepe, Francesco V.; Garuccio, Augusto; Scarcelli, Giuliano
2016-06-01
Plenoptic imaging is a promising optical modality that simultaneously captures the location and the propagation direction of light in order to enable three-dimensional imaging in a single shot. However, in standard plenoptic imaging systems, the maximum spatial and angular resolutions are fundamentally linked; thereby, the maximum achievable depth of field is inversely proportional to the spatial resolution. We propose to take advantage of the second-order correlation properties of light to overcome this fundamental limitation. In this Letter, we demonstrate that the correlation in both momentum and position of chaotic light leads to the enhanced refocusing power of correlation plenoptic imaging with respect to standard plenoptic imaging.
[Acoustic and aerodynamic characteristics of the oesophageal voice].
Vázquez de la Iglesia, F; Fernández González, S
2005-12-01
The aim of the study is to determine the physiology and pathophisiology of esophageal voice according to objective aerodynamic and acoustic parameters (quantitative and qualitative parameters). Our subjects were comprised of 33 laryngectomized patients (all male) that underwent aerodynamic, acoustic and perceptual protocol. There is a statistical association between acoustic and aerodynamic qualitative parameters (phonation flow chart type, sound spectrum, perceptual analysis) among quantitative parameters (neoglotic pressure, phonation flow, phonation time, fundamental frequency, maximum intensity sound level, speech rate). Nevertheles, not always such observations bring practical resources to clinical practice. We consider that the facts studied may enable us to add, pragmatically, new resources to the more effective vocal rehabilitation to these patients. The physiology of esophageal voice is well understood by the method we have applied, also seeking for rehabilitation, improving oral communication skills in the laryngectomee population.
[Basic principles and results of brachytherapy in gynecological oncology].
Kanaev, S V; Turkevich, V G; Baranov, S B; Savel'eva, V V
2014-01-01
The fundamental basics of contact radiation therapy (brachytherapy) for gynecological cancer are presented. During brachytherapy the principles of conformal radiotherapy should be implemented, the aim of which is to sum the maximum possible dose of radiation to the tumor and decrease the dose load in adjacent organs and tissues, which allows reducing the frequency of radiation damage at treatment of primary tumors. It is really feasible only on modern technological level, thanks to precision topometry preparation, optimal computer dosimetrical and radiobiological planning of each session and radiotherapy in general. Successful local and long-term results of the contact radiation therapy for cancer of cervix and endometrium are due to optimal anatomical and topometrical ratio of the tumor localization, radioactive sources, and also physical and radiobiological laws of distribution and effects of ionizing radiation, the dose load accounting rules.
Masghouni, N; Burton, J; Philen, M K; Al-Haik, M
2015-03-06
Hybrid piezoelectric composite structures that are able to convert mechanical energy into electricity have gained growing attention in the past few years. In this work, an energy harvesting composite beam is developed by growing piezoelectric zinc oxide nanowires on the surface of carbon fiber prior to forming structural composites. The piezoelectric behavior of the composite beam was demonstrated under different vibration sources such as water bath sonicator and permanent magnet vibration shaker. The beam was excited at its fundamental natural frequency (43.2 Hz) and the open circuit voltage and the short circuit current were measured to be 3.1 mV and 23 nA, respectively. Upon connecting an optimal resistor (1.2 kΩ) in series with the beam a maximum power output 2.5 nW was achieved.
A high power diode-side-pumped Nd:YAG/BaWO4 Raman laser at 1103 nm
NASA Astrophysics Data System (ADS)
Li, Lei; Zhang, Xingyu; Liu, Zhaojun; Wang, Qingpu; Cong, Zhenhua; Zhang, Yuangeng; Wang, Weitao; Wu, Zhenguo; Zhang, Huaijin
2013-04-01
Pulsed operation at 1103 nm of a diode-side-pumped Nd:YAG laser with intracavity Raman shifting in BaWO4 is reported. The first Stokes wavelength at 1103 nm was generated by a Raman shift of 332 cm-1 from the fundamental wave (1064 nm). A maximum power at 1103 nm of 9.4 W was obtained for a diode pump power of 115 W at a pulse repetition rate of 15 kHz. The pump-to-Stokes conversion efficiency was up to 8.2%. When the output power at 1103 nm was over 7 W, a second Stokes line at 1145 nm was also observed in the experiment. Our research indicates that efficient Raman conversion can be realized by a Raman frequency shift at 332 cm-1 in BaWO4 Raman lasers.
Rader, T; Fastl, H; Baumann, U
2017-03-01
After implantation of cochlear implants with hearing preservation for combined electronic acoustic stimulation (EAS), the residual acoustic hearing ability relays fundamental speech frequency information in the low frequency range. With the help of acoustic simulation of EAS hearing perception the impact of frequency and level fine structure of speech signals can be systematically examined. The aim of this study was to measure the speech reception threshold (SRT) under various noise conditions with acoustic EAS simulation by variation of the frequency and level information of the fundamental frequency f0 of speech. The study was carried out to determine to what extent the SRT is impaired by modification of the f0 fine structure. Using partial tone time pattern analysis an acoustic EAS simulation of the speech material from the Oldenburg sentence test (OLSA) was generated. In addition, determination of the f0 curve of the speech material was conducted. Subsequently, either the parameter frequency or level of f0 was fixed in order to remove one of the two fine contour information of the speech signal. The processed OLSA sentences were used to determine the SRT in background noise under various test conditions. The conditions "f0 fixed frequency" and "f0 fixed level" were tested under two different situations, under "amplitude modulated background noise" and "continuous background noise" conditions. A total of 24 subjects with normal hearing participated in the study. The SRT in background noise for the condition "f0 fixed frequency" was more favorable in continuous noise with 2.7 dB and in modulated noise with 0.8 dB compared to the condition "f0 fixed level" with 3.7 dB and 2.9 dB, respectively. In the simulation of speech perception with cochlear implants and acoustic components, the level information of the fundamental frequency had a stronger impact on speech intelligibility than the frequency information. The method of simulation of transmission of cochlear implants allows investigation of how various parameters influence speech intelligibility in subjects with normal hearing.
ERIC Educational Resources Information Center
Collyer, Sally; Thorpe, C. William; Callaghan, Jean; Davis, Pamela J.
2008-01-01
Purpose: This study investigated the influence of fundamental frequency (F0) and sound pressure level (SPL) range on respiratory behavior in classical singing. Method: Five trained female singers performed an 8-s messa di voce (a crescendo and decrescendo on one F0) across their musical F0 range. Lung volume (LV) change was estimated, and…
Code of Federal Regulations, 2010 CFR
2010-10-01
... fundamental frequency following the provisions of § 15.31(m). (3) For systems operating in the 23.12-29.0 GHz... with the transmitter operating continuously at a fundamental frequency. The video bandwidth of the... 47 Telecommunication 1 2010-10-01 2010-10-01 false Operation of wideband vehicular radar systems...
The stability of H/V spectral ratios from noise measurements in Armutlu Peninsula (Turkey)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Livaoğlu, Hamdullah, E-mail: hamdullah.livaoglu@kocaeli.edu.tr; Irmak, T. Serkan; Caka, Deniz
The horizontal to vertical spectral ratio (H/V) method has been successfully using in order to estimate the fundamental resonance frequency of the sedimentary cover, its thickness and amplification factor since at least 3 decades. There are numerous studies have been carried out on the stability of the H/V spectral ratios. Almost all studies showed that fundamental frequency is stable even measurements are repeated at different times. From this point of view, the results will show us an approach whether the stations are suitable for accurate estimate of earthquake studies and engineering purposes or not. Also we want to see ifmore » any effects of the amplification factor changing on the seismograms for Armutlu Seismic Network (ARNET) even though seismic stations are established far away from cultural noise and located on hard rock sites. It has been selected one hour recorded data of all stations during the most stationary times. The amplification and resonant frequency variations of H/V ratio were calculated to investigate temporal stability in time. There is a total harmony in fundamental frequencies values and H/V spectral ratio values in time-lagged periods. Some stations shows secondary minor peaks in high frequency band due to a shallow formation effect or cultural noises around. In the east side of the area ILYS station shows amplitude peak in lower fundamental frequency band from expected. This could compose a high amplification in lower frequencies and so that yield less reliable results in local earthquakes studies. By the experimental results from ambient noise analysis, it could be worked up for relocation of one station.« less
Fernández, María José; Driver, Marion E; Hedrick, Tyson L
2017-10-15
Flight performance is fundamental to the fitness of flying organisms. Whilst airborne, flying organisms face unavoidable wing wear and wing area loss. Many studies have tried to quantify the consequences of wing area loss to flight performance with varied results, suggesting that not all types of damage are equal and different species may have different means to compensate for some forms of wing damage with little to no cost. Here, we investigated the cost of control during hovering flight with damaged wings, specifically wings with asymmetric and symmetric reductions in area, by measuring maximum load lifting capacity and the metabolic power of hovering flight in hawkmoths ( Manduca sexta ). We found that while asymmetric and symmetric reductions are both costly in terms of maximum load lifting and hovering efficiency, asymmetric reductions are approximately twice as costly in terms of wing area lost. The moths also did not modulate flapping frequency and amplitude as predicted by a hovering flight model, suggesting that the ability to do so, possibly tied to asynchronous versus synchronous flight muscles, underlies the varied responses found in different wing clipping experiments. © 2017. Published by The Company of Biologists Ltd.
Free vibration analysis of microtubules based on the molecular mechanics and continuum beam theory.
Zhang, Jin; Wang, Chengyuan
2016-10-01
A molecular structural mechanics (MSM) method has been implemented to investigate the free vibration of microtubules (MTs). The emphasis is placed on the effects of the configuration and the imperfect boundaries of MTs. It is shown that the influence of protofilament number on the fundamental frequency is strong, while the effect of helix-start number is almost negligible. The fundamental frequency is also found to decrease as the number of the blocked filaments at boundaries decreases. Subsequently, the Euler-Bernoulli beam theory is employed to reveal the physics behind the simulation results. Fitting the Euler-Bernoulli beam into the MSM data leads to an explicit formula for the fundamental frequency of MTs with various configurations and identifies a possible correlation between the imperfect boundary conditions and the length-dependent bending stiffness of MTs reported in experiments.
[The speaking fundamental frequency and the singing voice type].
Chernobel'skiĭ, S I
2010-01-01
The objective of this study was to determine the speaking fundamental frequency (SFO) in professional opera singers and its dependence on their voice type, if any. A total of 75 persons were available for observation using a special computer clinical program. Male voices were categorized into three groups (viz, tenor, baritone, and bass), female ones into 2 groups (soprano and mezzo-soprano). It was shown that borderlines between SFO types varied within a wide range in all study groups. Significant differences in SFO were documented between tenors, baritones, and basses and between sopranos and mezzo-sopranos; the differences were insignificant between baritones and basses. It is concluded that the speaking fundamental frequency depends on the type of the singing voice; however this characteristic may serve only as an auxiliary tool but can not be used for the classification of singing voices.
NASA Astrophysics Data System (ADS)
Kamarudin, A. F.; Noh, M. S. Md; Mokhatar, S. N.; Anuar, M. A. Mohd; Ibrahim, A.; Ibrahim, Z.; Daud, M. E.
2018-04-01
Ambient vibration (AV) technique is widely used nowadays for ground fundamental frequency prediction. This technique is easy, quick, non-destructive, less operator required and reliable result. The input motions of ambient vibration are originally collected from surrounding natural and artificial excitations. But, careful data acquisition controlled must be implemented to reduce the intrusion of short period noise that could imply the quality of frequency prediction of an investigated site. In this study, investigation on the primary noise intrusion under peak (morning, afternoon and evening) and off peak (early morning) traffic flows (only 8 meter from sensor to road shoulder) against the stability and quality of ground fundamental frequency prediction were carried out. None of specific standard is available for AV data acquisition and processing. Thus, some field and processing parameters recommended by previous studies and guideline were considered. Two units of 1 Hz tri-axial seismometer sensor were closely positioned in front of the main entrance Universiti Tun Hussein Onn Malaysia. 15 minutes of recording length were taken during peak and off peak periods of traffic flows. All passing vehicles were counted and grouped into four classes. Three components of ambient vibration time series recorded in the North-South: NS, East-West: EW and vertical: UD directions were automatically computed into Horizontal to Vertical Spectral Ratio (HVSR), by using open source software of GEOPSY for fundamental ground frequency, Fo determination. Single sharp peak pattern of HVSR curves have been obtained at peak frequencies between 1.33 to 1.38 Hz which classified under soft to dense soil classification. Even identical HVSR curves pattern with close frequencies prediction were obtained under both periods of AV measurement, however the total numbers of stable and quality windows selected for HVSR computation were significantly different but both have satisfied the requirement given by SESAME (2004) guideline. Besides, the second peak frequencies from the early morning HVSR curve was clearly indicated between 8.23 to 8.55 Hz at very low amplitude (Ao < 2), but it should be neglected according to the similar guideline criteria. In conclusion, the ground fundamental frequency using HVSR method was successfully determined by 1 Hz seismometer instrument with recommended to specific parameters consideration on field as well as data processing, without disruption from the nearest traffic excitations.
100 Years of the Physics of Diodes
NASA Astrophysics Data System (ADS)
Luginsland, John
2013-10-01
The Child-Langmuir Law (CL), discovered 100 years ago, gives the maximum current that can be transported across a planar diode in the steady state. As a quintessential example of the impact of space-charge shielding near a charged surface, it is central to the studies of high current diodes, such as high power microwave sources, vacuum microelectronics, electron and ion sources, and high current drivers used in high-energy density physics experiments. CL remains a touchstone of fundamental sheath physics, including contemporary studies of nano-scale quantum diodes and plasmonic devices. Its solid state analog is the Mott-Gurney law, governing the maximum charge injection in solids, such as organic materials and other dielectrics, which is important to energy devices, such as solar cells and light-emitting diodes. This paper reviews the important advances in the physics of diodes since the discovery of CL, including virtual cathode formation and extension of CL to multiple dimensions, to the quantum regime, and to ultrafast processes. We will review the influence of magnetic fields, multiple species in bipolar flow, electromagnetic and time dependent effects in both short pulse and high frequency THz limits, and single electron regimes. Transitions from various emission mechanisms (thermionic, field, and photo-emission) to the space charge limited state (CL) will be addressed, especially highlighting important simulation and experimental developments in selected contemporary areas of study. This talk will stress the fundamental physical links between the physics of beams to limiting currents in other areas, such as low temperature plasmas, laser plasmas, and space propulsion. Also emphasized is the role of non-equilibrium phenomena associated with materials and plasmas in close contact. Work supported by the Air Force Office of Scientific Research.
Optimal observables for multiparameter seismic tomography
NASA Astrophysics Data System (ADS)
Bernauer, Moritz; Fichtner, Andreas; Igel, Heiner
2014-08-01
We propose a method for the design of seismic observables with maximum sensitivity to a target model parameter class, and minimum sensitivity to all remaining parameter classes. The resulting optimal observables thereby minimize interparameter trade-offs in multiparameter inverse problems. Our method is based on the linear combination of fundamental observables that can be any scalar measurement extracted from seismic waveforms. Optimal weights of the fundamental observables are determined with an efficient global search algorithm. While most optimal design methods assume variable source and/or receiver positions, our method has the flexibility to operate with a fixed source-receiver geometry, making it particularly attractive in studies where the mobility of sources and receivers is limited. In a series of examples we illustrate the construction of optimal observables, and assess the potentials and limitations of the method. The combination of Rayleigh-wave traveltimes in four frequency bands yields an observable with strongly enhanced sensitivity to 3-D density structure. Simultaneously, sensitivity to S velocity is reduced, and sensitivity to P velocity is eliminated. The original three-parameter problem thereby collapses into a simpler two-parameter problem with one dominant parameter. By defining parameter classes to equal earth model properties within specific regions, our approach mimics the Backus-Gilbert method where data are combined to focus sensitivity in a target region. This concept is illustrated using rotational ground motion measurements as fundamental observables. Forcing dominant sensitivity in the near-receiver region produces an observable that is insensitive to the Earth structure at more than a few wavelengths' distance from the receiver. This observable may be used for local tomography with teleseismic data. While our test examples use a small number of well-understood fundamental observables, few parameter classes and a radially symmetric earth model, the method itself does not impose such restrictions. It can easily be applied to large numbers of fundamental observables and parameters classes, as well as to 3-D heterogeneous earth models.
A Valid Demonstration of the Missing Fundamental Illusion.
ERIC Educational Resources Information Center
Larsen, Janet D.; Fritsch, Klaus
1998-01-01
Identifies the "missing fundamental illusion" as that which occurs when two tones are heard together and the listener hears a third tone with a pitch corresponding to the difference in their frequencies. Describes an inexpensive and valid demonstration of the missing fundamental using a British police whistle. (MJP)
Fundamentals of Coherent Synchrotron Radiation in Storage Rings
NASA Astrophysics Data System (ADS)
Sannibale, F.; Byrd, J. M.; Loftsdottir, A.; Martin, M. C.; Venturini, M.
2004-05-01
We present the fundamental concepts for producing stable broadband coherent synchrotron radiation (CSR) in the terahertz frequency region in an electron storage ring. The analysis includes distortion of bunch shape from the synchrotron radiation (SR), enhancing higher frequency coherent emission and limits to stable emission due to a microbunching instability excited by the SR. We use these concepts to optimize the performance of a source for CSR emission.
A two-layer composite model of the vocal fold lamina propria for fundamental frequency regulation.
Zhang, Kai; Siegmund, Thomas; Chan, Roger W
2007-08-01
The mechanical properties of the vocal fold lamina propria, including the vocal fold cover and the vocal ligament, play an important role in regulating the fundamental frequency of human phonation. This study examines the equilibrium hyperelastic tensile deformation behavior of cover and ligament specimens isolated from excised human larynges. Ogden's hyperelastic model is used to characterize the tensile stress-stretch behaviors at equilibrium. Several statistically significant differences in the mechanical response differentiating cover and ligament, as well as gender are found. Fundamental frequencies are predicted from a string model and a beam model, both accounting for the cover and the ligament. The beam model predicts nonzero F(0) for the unstretched state of the vocal fold. It is demonstrated that bending stiffness significantly contributes to the predicted F(0), with the ligament contributing to a higher F(0), especially in females. Despite the availability of only a small data set, the model predicts an age dependence of F(0) in males in agreement with experimental findings. Accounting for two mechanisms of fundamental frequency regulation--vocal fold posturing (stretching) and extended clamping--brings predicted F(0) close to the lower bound of the human phonatory range. Advantages and limitations of the current model are discussed.
NASA Astrophysics Data System (ADS)
Shi, Jin-Xing; Ohmura, Keiichiro; Shimoda, Masatoshi; Lei, Xiao-Wen
2018-07-01
In recent years, shape design of graphene sheets (GSs) by introducing topological defects for enhancing their mechanical behaviors has attracted the attention of scholars. In the present work, we propose a consistent methodology for optimal shape design of GSs using a combination of the molecular mechanics (MM) method, the non-parametric shape optimization method, the phase field crystal (PFC) method, Voronoi tessellation, and molecular dynamics (MD) simulation to maximize their fundamental frequencies. At first, we model GSs as continuum frame models using a link between the MM method and continuum mechanics. Then, we carry out optimal shape design of GSs in fundamental frequency maximization problem based on a developed shape optimization method for frames. However, the obtained optimal shapes of GSs only consisting of hexagonal carbon rings are unstable that do not satisfy the principle of least action, so we relocate carbon atoms on the optimal shapes by introducing topological defects using the PFC method and Voronoi tessellation. At last, we perform the structural relaxation through MD simulation to determine the final optimal shapes of GSs. We design two examples of GSs and the optimal results show that the fundamental frequencies of GSs can be significantly enhanced according to the optimal shape design methodology.
NASA Astrophysics Data System (ADS)
Abd el-aal, Abd el-aziz Khairy
2018-05-01
In this contribution, new relationship between the fundamental site frequency and the thickness of soft sediments is obtained for many sites in Egypt. The Horizontal-to-Vertical Spectral Ratio ("H/V") technique (known as Nakamura technique) can be used as a robust tool to determine the thickness of soft sediments layers overlaying bedrock from observations and measurements of seismic ambient noise data. In Egypt, numerous seismic ambient noise measurements have been conducted in several areas to determine the dynamic properties of soft soil for engineering purposes. At each site in each studied area, the fundamental site frequency was accurately estimated from the main peak in the spectral ratio between the horizontal and vertical component. Consequently, an extensive database of microtremor measurements, well logging data, and shallow seismic refraction data have been configured and assembled for the studied areas. New formula between fundamental site frequency (f 0 ) and thickness of soft sediments (h) is established. The new formula has been validated and compared with other formulas of earlier scientists, and the results indicate that the calculated depth and geometry of the bedrock surface using new formula are in a good agreement with well logs data and previously published seismic refraction surveys in the investigated sites.
Cross-Linguistic Differences in Bilinguals' Fundamental Frequency Ranges.
Ordin, Mikhail; Mennen, Ineke
2017-06-10
We investigated cross-linguistic differences in fundamental frequency range (FFR) in Welsh-English bilingual speech. This is the first study that reports gender-specific behavior in switching FFRs across languages in bilingual speech. FFR was conceptualized as a behavioral pattern using measures of span (range of fundamental frequency-in semitones-covered by the speaker's voice) and level (overall height of fundamental frequency maxima, minima, and means of speaker's voice) in each language. FFR measures were taken from recordings of 30 Welsh-English bilinguals (14 women and 16 men), who read 70 semantically matched sentences, 35 in each language. Comparisons were made within speakers across languages, separately in male and female speech. Language background and language use information was elicited for qualitative analysis of extralinguistic factors that might affect the FFR. Cross-linguistic differences in FFR were found to be consistent across female bilinguals but random across male bilinguals. Most female bilinguals showed distinct FFRs for each language. Most male bilinguals, however, were found not to change their FFR when switching languages. Those who did change used different strategies than women when differentiating FFRs between languages. Detected cross-linguistic differences in FFR can be explained by sociocultural factors. Therefore, sociolinguistic factors are to be taken into account in any further study of language-specific pitch setting and cross-linguistic differences in FFR.
Haefner, Ralph J.; Sheets, Rodney A.; Andrews, Robert E.
2011-01-01
The horizontal-to-vertical spectral ratio (HVSR) seismic method involves analyzing measurements of ambient seismic noise in three dimensions to determine the fundamental site resonance frequency. Resonance is excited by the interaction of surface waves (Rayleigh and Love) and body waves (vertically incident shear) with the high-contrast aconstic impedance boundary at the bedrock-sediment interface. Measurements were made to determine the method's utility for estimating thickness of unconsolidated glacial sediments at 18 locations at the South Well Field, Franklin County, OH, and at six locations in Pickaway County where sediment thickness was already known. Measurements also were made near a high-capacity production well (with pumping on and off) and near a highway and a limestone quarry to examine changes in resonance frequencies over a 20-hour period. Although the regression relation for resonance frequency and sediment thickness had a relatively low [r.sup.2] (0.322), estimates of sediment thickness were, on average, within 14 percent of known thicknesses. Resonance frequencies for pumping on and pumping off were identical, although the amplitude of the peak was nearly double under pumping conditions. Resonance frequency for the 20-hour period did not change, but the amplitude of the peak changed considerably, with a maximum amplitude in the early afternoon and minimum in the very early morning hours. Clay layers within unconsolidated sediments may influence resonance frequency and the resulting regression equation, resulting in underestimation of sediment thickness; however, despite this and other complicating factors, hydrogeologists should consider this method when thickness data are needed for unconsolidated sediments.
Haefner, R.J.; Sheets, R.A.; Andrews, R.E.
2010-01-01
The horizontal-to-vertical spectral ratio (HVSR) seismic method involves analyzing measurements of ambient seismic noise in three dimensions to determine the fundamental site resonance frequency. Resonance is excited by the interaction of surface waves (Rayleigh and Love) and body waves (vertically incident shear) with the high-contrast acoustic impedance boundary at the bedrock-sediment interface. Measurements were made to determine the method's utility for estimating thickness of unconsolidated glacial sediments at 18 locations at the South Well Field, Franklin County, OH, and at six locations in Pickaway County where sediment thickness was already known. Measurements also were made near a high-capacity production well (with pumping on and off ) and near a highway and a limestone quarry to examine changes in resonance frequencies over a 20-hour period. Although the regression relation for resonance frequency and sediment thickness had a relatively low r 2(0.322), estimates of sediment thickness were, on average, within 14 percent of known thicknesses. Resonance frequencies for pumping on and pumping off were identical, although the amplitude of the peak was nearly double under pumping conditions. Resonance frequency for the 20-hour period did not change, but the amplitude of the peak changed considerably, with a maximum amplitude in the early afternoon and minimum in the very early morning hours. Clay layers within unconsolidated sediments may influence resonance frequency and the resulting regression equation, resulting in underestimation of sediment thickness; however, despite this and other complicating factors, hydrogeologists should consider this method when thickness data are needed for unconsolidated sediments. ?? 2011 by The Ohio Academy of Science. All Rights Reserved.
NASA Astrophysics Data System (ADS)
Schneider, Thomas
2015-03-01
High-quality frequency comb sources like femtosecond-lasers have revolutionized the metrology of fundamental physical constants. The generated comb consists of frequency lines with an equidistant separation over a bandwidth of several THz. This bandwidth can be broadened further to a super-continuum of more than an octave through propagation in nonlinear media. The frequency separation between the lines is defined by the repetition rate and the width of each comb line can be below 1 Hz, even without external stabilization. By extracting just one of these lines, an ultra-narrow linewidth, tunable laser line for applications in communications and spectroscopy can be generated. If two lines are extracted, the superposition of these lines in an appropriate photo-mixer produces high-quality millimeter- and THz-waves. The extraction of several lines can be used for the creation of almost-ideally sinc-shaped Nyquist pulses, which enable optical communications with the maximum-possible baud rate. Especially combs generated by low-cost, small-footprint fs-fiber lasers are very promising. However due to the resonator length, the comb frequencies have a typical separation of 80 - 100 MHz, far too narrow for the selection of single tones with standard optical filters. Here the extraction of single lines of an fs-fiber laser by polarization pulling assisted stimulated Brillouin scattering is presented. The application of these extracted lines as ultra-narrow, stable and tunable laser lines, for the generation of very high-quality mm and THz-waves with an ultra-narrow linewidth and phase noise and for the generation of sinc-shaped Nyquist pulses with arbitrary bandwidth and repetition rate is discussed.
Effect of Training Frequency on Maximum Expiratory Pressure
ERIC Educational Resources Information Center
Anand, Supraja; El-Bashiti, Nour; Sapienza, Christine
2012-01-01
Purpose: To determine the effects of expiratory muscle strength training (EMST) frequency on maximum expiratory pressure (MEP). Method: We assigned 12 healthy participants to 2 groups of training frequency (3 days per week and 5 days per week). They completed a 4-week training program on an EMST trainer (Aspire Products, LLC). MEP was the primary…
NASA Astrophysics Data System (ADS)
Parolai, S.; Richwalski, S. M.; Milkereit, C.; Bormann, P.
Situated in an active tectonic region the highly industrialised Cologne area (Germany) suffers from moderate sized earthquakes. The mitigation of earthquake risk included a microzonation study with ambient seismic noise and earthquake recordings in two field campaigns. The analysis of the ambient noise data using the horizontal-to-vertical (H/V) spectral ratio allowed for mapping the fundamental resonance frequency of soils in this area. Furthermore, adding independent geological information we calculated new relationships between shear-wave velocity, sediment thickness, and resonance frequency. The stability of the H/V ratio of ambient noise was checked with repeated measurements and the following observations and conclusions can be drawn: (1) The fundamental resonance frequency estimated from the peak in the H/V ratio is stable in time but the amplification factor is not. (2) Therefore, the relative amplification vari- ation in the area should be checked systematically with repeated measurements. (3) The thickness of the sediments is reliably retrieved from the fundamental resonance frequency. The H/V ratio of ambient noise recordings was compared with the H/V ratio of earth- quake recordings as well as with the curves obtained by applying the classical spectral ratio technique (using a reference site). The shapes of the spectral ratios obtained by the different methods are generally in good agreement.In addition, the analysis of earthquake data shows that significant amplifications of the ground motion may also occur at frequencies higher than the fundamental one.
Real time analysis of voiced sounds
NASA Technical Reports Server (NTRS)
Hong, J. P. (Inventor)
1976-01-01
A power spectrum analysis of the harmonic content of a voiced sound signal is conducted in real time by phase-lock-loop tracking of the fundamental frequency, (f sub 0) of the signal and successive harmonics (h sub 1 through h sub n) of the fundamental frequency. The analysis also includes measuring the quadrature power and phase of each frequency tracked, differentiating the power measurements of the harmonics in adjacent pairs, and analyzing successive differentials to determine peak power points in the power spectrum for display or use in analysis of voiced sound, such as for voice recognition.
Porcu, Emanuele; Keitel, Christian; Müller, Matthias M
2013-11-27
We investigated effects of inter-modal attention on concurrent visual and tactile stimulus processing by means of stimulus-driven oscillatory brain responses, so-called steady-state evoked potentials (SSEPs). To this end, we frequency-tagged a visual (7.5Hz) and a tactile stimulus (20Hz) and participants were cued, on a trial-by-trial basis, to attend to either vision or touch to perform a detection task in the cued modality. SSEPs driven by the stimulation comprised stimulus frequency-following (i.e. fundamental frequency) as well as frequency-doubling (i.e. second harmonic) responses. We observed that inter-modal attention to vision increased amplitude and phase synchrony of the fundamental frequency component of the visual SSEP while the second harmonic component showed an increase in phase synchrony, only. In contrast, inter-modal attention to touch increased SSEP amplitude of the second harmonic but not of the fundamental frequency, while leaving phase synchrony unaffected in both responses. Our results show that inter-modal attention generally influences concurrent stimulus processing in vision and touch, thus, extending earlier audio-visual findings to a visuo-tactile stimulus situation. The pattern of results, however, suggests differences in the neural implementation of inter-modal attentional influences on visual vs. tactile stimulus processing. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Auditory biological marker of concussion in children
Kraus, Nina; Thompson, Elaine C.; Krizman, Jennifer; Cook, Katherine; White-Schwoch, Travis; LaBella, Cynthia R.
2016-01-01
Concussions carry devastating potential for cognitive, neurologic, and socio-emotional disease, but no objective test reliably identifies a concussion and its severity. A variety of neurological insults compromise sound processing, particularly in complex listening environments that place high demands on brain processing. The frequency-following response captures the high computational demands of sound processing with extreme granularity and reliably reveals individual differences. We hypothesize that concussions disrupt these auditory processes, and that the frequency-following response indicates concussion occurrence and severity. Specifically, we hypothesize that concussions disrupt the processing of the fundamental frequency, a key acoustic cue for identifying and tracking sounds and talkers, and, consequently, understanding speech in noise. Here we show that children who sustained a concussion exhibit a signature neural profile. They have worse representation of the fundamental frequency, and smaller and more sluggish neural responses. Neurophysiological responses to the fundamental frequency partially recover to control levels as concussion symptoms abate, suggesting a gain in biological processing following partial recovery. Neural processing of sound correctly identifies 90% of concussion cases and clears 95% of control cases, suggesting this approach has practical potential as a scalable biological marker for sports-related concussion and other types of mild traumatic brain injuries. PMID:28005070
Crystal oscillators using negative voltage gain, single pole response amplifiers
NASA Technical Reports Server (NTRS)
Kleinberg, Leonard L. (Inventor)
1989-01-01
A simple and inexpensive crystal oscillator is provided which employs negative voltage gain, single pole response amplifiers. The amplifiers may include such configurations as gate inverters, operational amplifiers and conventional bipolar transistor amplifiers, all of which operate at a frequency which is on the roll-off portion of their gain versus frequency curve. Several amplifier feedback circuit variations are employed to set desired bias levels and to allow the oscillator to operate at the crystal's fundamental frequency or at an overtone of the fundamental frequency. The oscillator is made less expensive than comparable oscillators by employing relatively low frequency amplifiers and operating them at roll-off, at frequencies beyond which they are customarily used. Simplicity is provided because operation at roll-off eliminates components ordinarily required in similar circuits to provide sufficient phase-shift in the feedback circuitry for oscillation to occur.
Nonlinear Optical Effects in Liquid Crystals.
1980-12-10
susceptibilities Lasers , Nematic, Cholesteric, Flexoelectric, Second-harmonic generation 20M AV*--YRAc rR-r, m, revere i It nf le4U7 siad Idsiully byr...samples are irradiated with laser beam at the fundamental frequency. The laser used in a Q-switched Nd-YAG laser . Sample alignment is achieved either...irradiated with laser beam at the fundamental frequency. The laser used is a Q-switched Nd-YAG laser . Sample alignment is achieved either with rubbing
NASA Technical Reports Server (NTRS)
Huang, Xinchuan; Fortenberry, Ryan C.; Lee, Timothy J.
2013-01-01
The interstellar presence of protonated nitrous oxide has been suspected for some time. Using established high-accuracy quantum chemical techniques, spectroscopic constants and fundamental vibrational frequencies are provided for the lower energy O-protonated isomer of this cation and its deuterated isotopologue. The vibrationally-averaged B0 and C0 rotational constants are within 6 MHz of their experimental values and the D(subJ) quartic distortion constants agree with experiment to within 3%. The known gas phase O-H stretch of NNOH(+) is 3330.91 cm(exp-1), and the vibrational configuration interaction computed result is 3330.9 cm(exp-1). Other spectroscopic constants are also provided, as are the rest of the fundamental vibrational frequencies for NNOH(+) and its deuterated isotopologue. This high-accuracy data should serve to better inform future observational or experimental studies of the rovibrational bands of protonated nitrous oxide in the ISM and the laboratory.
Monaural Sound Localization Based on Structure-Induced Acoustic Resonance
Kim, Keonwook; Kim, Youngwoong
2015-01-01
A physical structure such as a cylindrical pipe controls the propagated sound spectrum in a predictable way that can be used to localize the sound source. This paper designs a monaural sound localization system based on multiple pyramidal horns around a single microphone. The acoustic resonance within the horn provides a periodicity in the spectral domain known as the fundamental frequency which is inversely proportional to the radial horn length. Once the system accurately estimates the fundamental frequency, the horn length and corresponding angle can be derived by the relationship. The modified Cepstrum algorithm is employed to evaluate the fundamental frequency. In an anechoic chamber, localization experiments over azimuthal configuration show that up to 61% of the proper signal is recognized correctly with 30% misfire. With a speculated detection threshold, the system estimates direction 52% in positive-to-positive and 34% in negative-to-positive decision rate, on average. PMID:25668214
A wearable multichannel tactile display of voice fundamental frequency.
Yeung, E; Boothroyd, A; Redmond, C
1988-12-01
This paper describes a wearable sensory aid that provides the deaf with tactually encoded information about intonation. Fundamental frequency is represented as both place and rate of vibration in a linear array of solenoids. Pitch extraction is accomplished through low-pass filtering and peak detection. A microcomputer is used to measure pitch period, which in turn determines which of the solenoids is actuated. By comparing consecutive periods, the system discriminates against random, noise-related inputs. The device is switchable between 1-, 8-, and 16-channel operation. The electronics package is contained in a case that may be worn on a belt. The solenoid array is worn on the forearm. The system is powered by five, rechargeable lithium cells and runs for at least 6 hours between charges. Proposed developments include the incorporation of digital pitch extraction methods and the option to use the spatial output dimension to encode speech parameters other than fundamental frequency.
Liu, Weimin; Zhu, Liangdong; Fang, Chong
2012-09-15
We demonstrate the simultaneous generation of multicolor femtosecond laser pulses spanning the wavelength range from UV to near IR in a 0.1 mm Type I beta-barium borate crystal from 800 nm fundamental and weak IR super-continuum white light (SCWL) pulses. The multicolor broadband laser pulses observed are attributed to two concomitant cascaded four-wave mixing (CFWM) processes as corroborated by calculation: (1) directly from the two incident laser pulses; (2) by the sum-frequency generation (SFG) induced CFWM process (SFGFWM). The latter signal arises from the interaction between the frequency-doubled fundamental pulse (400 nm) and the SFG pulse generated in between the fundamental and IR-SCWL pulses. The versatility and simplicity of this spatially dispersed multicolor self-compressed laser pulse generation offer compact and attractive methods to conduct femtosecond stimulated Raman spectroscopy and time-resolved multicolor spectroscopy.
1992-01-01
careful design of the device to maximise the relaxation oscillation resonance frequency [2], minimize leakage currents [2,3], and optimize other...and determines the maximum frequency of operation. With hybrid circuit construction this maximum frequency would generally be in the order of a few...operating at a frequency of 335.48 MHz. The resultant timing jitter is determined by sending both pulse trains into a rotating mirror optical
Effect of current on the maximum possible reward.
Gallistel, C R; Leon, M; Waraczynski, M; Hanau, M S
1991-12-01
Using a 2-lever choice paradigm with concurrent variable interval schedules of reward, it was found that when pulse frequency is increased, the preference-determining rewarding effect of 0.5-s trains of brief cathodal pulses delivered to the medial forebrain bundle of the rat saturates (stops increasing) at values ranging from 200 to 631 pulses/s (pps). Raising the current lowered the saturation frequency, which confirms earlier, more extensive findings showing that the rewarding effect of short trains saturates at pulse frequencies that vary from less than 100 pps to more than 800 pps, depending on the current. It was also found that the maximum possible reward--the magnitude of the reward at or beyond the saturation pulse frequency--increases with increasing current. Thus, increasing the current reduces the saturation frequency but increases the subjective magnitude of the maximum possible reward.
Lip Movement Exaggerations During Infant-Directed Speech
Green, Jordan R.; Nip, Ignatius S. B.; Wilson, Erin M.; Mefferd, Antje S.; Yunusova, Yana
2011-01-01
Purpose Although a growing body of literature has indentified the positive effects of visual speech on speech and language learning, oral movements of infant-directed speech (IDS) have rarely been studied. This investigation used 3-dimensional motion capture technology to describe how mothers modify their lip movements when talking to their infants. Method Lip movements were recorded from 25 mothers as they spoke to their infants and other adults. Lip shapes were analyzed for differences across speaking conditions. The maximum fundamental frequency, duration, acoustic intensity, and first and second formant frequency of each vowel also were measured. Results Lip movements were significantly larger during IDS than during adult-directed speech, although the exaggerations were vowel specific. All of the vowels produced during IDS were characterized by an elevated vocal pitch and a slowed speaking rate when compared with vowels produced during adult-directed speech. Conclusion The pattern of lip-shape exaggerations did not provide support for the hypothesis that mothers produce exemplar visual models of vowels during IDS. Future work is required to determine whether the observed increases in vertical lip aperture engender visual and acoustic enhancements that facilitate the early learning of speech. PMID:20699342
Amplifier based broadband pixel for sub-millimeter wave imaging
NASA Astrophysics Data System (ADS)
Sarkozy, Stephen; Drewes, Jonathan; Leong, Kevin M. K. H.; Lai, Richard; Mei, X. B. (Gerry); Yoshida, Wayne; Lange, Michael D.; Lee, Jane; Deal, William R.
2012-09-01
Broadband sub-millimeter wave technology has received significant attention for potential applications in security, medical, and military imaging. Despite theoretical advantages of reduced size, weight, and power compared to current millimeter wave systems, sub-millimeter wave systems have been hampered by a fundamental lack of amplification with sufficient gain and noise figure properties. We report a broadband pixel operating from 300 to 340 GHz, biased off a single 2 V power supply. Over this frequency range, the amplifiers provide > 40 dB gain and <8 dB noise figure, representing the current state-of-art performance capabilities. This pixel is enabled by revolutionary enhancements to indium phosphide (InP) high electron mobility transistor technology, based on a sub-50 nm gate and indium arsenide composite channel with a projected maximum oscillation frequency fmax>1.0 THz. The first sub-millimeter wave-based images using active amplification are demonstrated as part of the Joint Improvised Explosive Device Defeat Organization Longe Range Personnel Imager Program. This development and demonstration may bring to life future sub-millimeter-wave and THz applications such as solutions to brownout problems, ultra-high bandwidth satellite communication cross-links, and future planetary exploration missions.
NASA Astrophysics Data System (ADS)
Zhang, Hui; Corr, Lawrence R.; Ma, Tianwei
2018-02-01
To further advance the existing knowledge base on rectified vibration energy harvester design, this study investigates the fundamental effects of electrical loads containing non-resistive components (e.g., rectifiers and capacitors) on electromagnetic energy harvester performance. Three types of electrical loads, namely (I) a resistor with a rectifier, (II) a resistor with a rectifier and a capacitor, and (III) a simple charging circuit consisting of a rectifier and a capacitor, were considered. A linear electromagnetic energy harvester was used as an illustrative example. Results have verified that device performance obtained from pure-resistive loads cannot be generalized to applications involving rectifier and/or capacitor loads. Such generalization caused not only an overestimation in the maximum power delivered to the load resistance for cases (I) and (II), but also an underestimation of the optimal load resistance and an overestimation of device natural frequency for case (II). Results obtained from case (II) also showed that it is possible to tune the mechanical natural frequency of device using an adjustable regulating capacitor. For case (III), it was found that a larger storing capacitor, with a low rectifier voltage drop, improves the performance of the electromagnetic harvester.
How Life History Can Sway the Fixation Probability of Mutants
Li, Xiang-Yi; Kurokawa, Shun; Giaimo, Stefano; Traulsen, Arne
2016-01-01
In this work, we study the effects of demographic structure on evolutionary dynamics when selection acts on reproduction, survival, or both. In contrast to the previously discovered pattern that the fixation probability of a neutral mutant decreases while the population becomes younger, we show that a mutant with a constant selective advantage may have a maximum or a minimum of the fixation probability in populations with an intermediate fraction of young individuals. This highlights the importance of life history and demographic structure in studying evolutionary dynamics. We also illustrate the fundamental differences between selection on reproduction and selection on survival when age structure is present. In addition, we evaluate the relative importance of size and structure of the population in determining the fixation probability of the mutant. Our work lays the foundation for also studying density- and frequency-dependent effects in populations when demographic structures cannot be neglected. PMID:27129737
Lab-on-a-chip Single Particle Dielectrophoretic Traps
NASA Astrophysics Data System (ADS)
Wang, Weina; Shao, Hua; Lear, Kevin
2007-03-01
Cell-patterning and cell-manipulation in micro-environments are fundamental to biological and biomedical applications, for example, spectroscopic cytology based cancer detection. Dielectrophoresis (DEP) traps with transparent centers for stabilized cell and particle optofluidic intracavity spectroscopy (OFIS) were fabricated by patterning 10 μm wide, planar gold electrodes on glass substrates. The capturing strength of DEP traps was quantified based on the minimum AC voltage required to capture and hold varying diameter polystyrene or was it some other material, e.g. silica or PMMA microspheres in water as a function of frequency required under a constant flowrate of 20 μm/s. The maximum required trapping voltage in the negative DEP regime of f = 1 kHz to 40 MHz was 5.0 VAC. The use of AC fields effectively suppressed hydrolysis. New geometries of DEP traps are being explored on the basis of 3-D electrostatic field simulations.
The Prosody of Topic Transition in Interaction: Pitch Register Variations.
Riou, Marine
2017-12-01
In conversation, speakers can mobilize a variety of prosodic cues to signal a switch in topics. This paper uses a mixed-methods approach combining Conversation Analysis and Instrumental Prosody to investigate the prosody of topic transition in American English, and analyzes the ways in which speakers can play on register level and on register span. A cluster of three prosodic parameters was found to be predictive of transitions: a higher maximum fundamental frequency (F0), a higher median F0 (key), and an expanded register span. Relative to speakers' habitual profiles, the mobilization of such prosodic cues corresponds to a marked upgraded prosodic design. This finding is consistent with the general assumption that continuation constitutes the norm in conversation, and that departing from it, as in the case of a topic transition, requires a marked action and marked linguistic design. The disjunctive action of opening a new topic corresponds to the use of a marked prosodic cue.
Note: Design and capability verification of fillet triangle flexible support
NASA Astrophysics Data System (ADS)
Wang, Tao; San, Xiao-Gang; Gao, Shi-Jie; Wang, Jing; Ni, Ying-Xue; Sang, Zhi-Xin
2017-12-01
By increasing the section thickness of a triangular flexible hinge, this study focuses on optimal selection of parameters of fillet triangle flexible hinges and flexible support. Based on Castigliano's second theorem, the flexibility expression of the fillet triangle flexible hinge was derived. Then, the case design is performed, and the comparison of three types of flexible hinges with this type of flexible hinge was carried out. The finite element models of fillet triangle flexible hinges and flexible support were built, and then the simulation results of performance parameters were calculated. Finally, the experiment platform was established to validate analysis results. The maximum error is less than 8%, which verifies the accuracy of the simulation process and equations derived; also the fundamental frequency fits the requirements of the system. The fillet triangle flexible hinge is proved to have the advantages of high precision and low flexibility.
Signal to noise ratio calculation for fiber optics links
NASA Technical Reports Server (NTRS)
Lau, K. Y.
1980-01-01
The signal to noise ratio (SNR) effect upon the maximum transmission length of a fiberoptic system is discussed. The relationships of different system parameters are discussed. A general formula to obtain the SNR of a single mode fiberoptic system is derived. The SNR attainable with single mode and multimode fiber optics links was calculated from fundamental noise considerations. It was found that for single mode fibers, laser noise dominates the noise contributions for links less than 30 km long, while thermal noise dominates for longer links. Multimode fibers degrade SNR for long links because of intermode dispersion. For frequency standard transmission, as long as the baseband modulation signals are within the bandwidth of the fibers, respectable SNR can be attained with low loss fibers (approximately 1 dB/km) for links as long as 70 km. For wideband transmission SNR is decreased by a factor equal to the ratio of the bandwidth.
Note: Design and capability verification of fillet triangle flexible support.
Wang, Tao; San, Xiao-Gang; Gao, Shi-Jie; Wang, Jing; Ni, Ying-Xue; Sang, Zhi-Xin
2017-12-01
By increasing the section thickness of a triangular flexible hinge, this study focuses on optimal selection of parameters of fillet triangle flexible hinges and flexible support. Based on Castigliano's second theorem, the flexibility expression of the fillet triangle flexible hinge was derived. Then, the case design is performed, and the comparison of three types of flexible hinges with this type of flexible hinge was carried out. The finite element models of fillet triangle flexible hinges and flexible support were built, and then the simulation results of performance parameters were calculated. Finally, the experiment platform was established to validate analysis results. The maximum error is less than 8%, which verifies the accuracy of the simulation process and equations derived; also the fundamental frequency fits the requirements of the system. The fillet triangle flexible hinge is proved to have the advantages of high precision and low flexibility.
NASA Technical Reports Server (NTRS)
Jin, R. S.
1975-01-01
Power spectral density analysis using Burg's maximum entropy method was applied to the geomagnetic dipole field and its rate of change for the years 1901 to 1969. Both spectra indicate relative maxima at 0.015 cycles/year and its harmonics. These maxima correspond approximately to 66, 33, 22, 17, 13, 11, and 9-year spectral lines. The application of the same analysis techniques to the length-of-day (l.o.d) fluctuations for the period 1865 to 1961 reveal similar spectral characteristics. Although peaks were observed at higher harmonics of the fundamental frequency, the 22-year and 11-year lines are not attributed unambiguously to the solar magnetic cycle and the solar cycle. It is suggested that the similarity in the l.o.d fluctuations and the dipole field variations is related to the motion within the earth's fluid core during the past one hundred years.
Kesharwani, Manoj K; Brauer, Brina; Martin, Jan M L
2015-03-05
We have obtained uniform frequency scaling factors λ(harm) (for harmonic frequencies), λ(fund) (for fundamentals), and λ(ZPVE) (for zero-point vibrational energies (ZPVEs)) for the Weigend-Ahlrichs and other selected basis sets for MP2, SCS-MP2, and a variety of DFT functionals including double hybrids. For selected levels of theory, we have also obtained scaling factors for true anharmonic fundamentals and ZPVEs obtained from quartic force fields. For harmonic frequencies, the double hybrids B2PLYP, B2GP-PLYP, and DSD-PBEP86 clearly yield the best performance at RMSD = 10-12 cm(-1) for def2-TZVP and larger basis sets, compared to 5 cm(-1) at the CCSD(T) basis set limit. For ZPVEs, again, the double hybrids are the best performers, reaching root-mean-square deviations (RMSDs) as low as 0.05 kcal/mol, but even mainstream functionals like B3LYP can get down to 0.10 kcal/mol. Explicitly anharmonic ZPVEs only are marginally more accurate. For fundamentals, however, simple uniform scaling is clearly inadequate.
Joint inversion of high-frequency surface waves with fundamental and higher modes
Luo, Y.; Xia, J.; Liu, J.; Liu, Q.; Xu, S.
2007-01-01
Joint inversion of multimode surface waves for estimating the shear (S)-wave velocity has received much attention in recent years. In this paper, we first analyze sensitivity of phase velocities of multimodes of surface waves for a six-layer earth model, and then we invert surface-wave dispersion curves of the theoretical model and a real-world example. Sensitivity analysis shows that fundamental mode data are more sensitive to the S-wave velocities of shallow layers and are concentrated on a very narrow frequency band, while higher mode data are more sensitive to the parameters of relatively deeper layers and are distributed over a wider frequency band. These properties provide a foundation of using a multimode joint inversion to define S-wave velocities. Inversion results of both synthetic data and a real-world example demonstrate that joint inversion with the damped least-square method and the singular-value decomposition technique to invert high-frequency surface waves with fundamental and higher mode data simultaneously can effectively reduce the ambiguity and improve the accuracy of S-wave velocities. ?? 2007.
Modeling and Frequency Tracking of Marine Mammal Whistle Calls
2009-02-01
retrieve em- bedded information from watermarked synthetic whistle calls. Different fundamental frequency watermarking schemes are proposed b&ed on...unmodified frequency contour is relatively constant, there is little frequency separation between information bits, and watermark retrieval requires...UHYLHZLQJWKHFROOHFWLRQRILQIRUPDWLRQ6HQGFRPPHQWVUHJDUGLQJWKLVEXUGHQHVWLPDWH RU DQ\\RWKHUDVSHFWRIWKLVFROOHFWLRQ RI LQIRUPDWLRQ LQFOXGLQJ
The historical bases of the Rayleigh and Ritz methods
NASA Astrophysics Data System (ADS)
Leissa, A. W.
2005-11-01
Rayleigh's classical book Theory of Sound was first published in 1877. In it are many examples of calculating fundamental natural frequencies of free vibration of continuum systems (strings, bars, beams, membranes, plates) by assuming the mode shape, and setting the maximum values of potential and kinetic energy in a cycle of motion equal to each other. This procedure is well known as "Rayleigh's Method." In 1908, Ritz laid out his famous method for determining frequencies and mode shapes, choosing multiple admissible displacement functions, and minimizing a functional involving both potential and kinetic energies. He then demonstrated it in detail in 1909 for the completely free square plate. In 1911, Rayleigh wrote a paper congratulating Ritz on his work, but stating that he himself had used Ritz's method in many places in his book and in another publication. Subsequently, hundreds of research articles and many books have appeared which use the method, some calling it the "Ritz method" and others the "Rayleigh-Ritz method." The present article examines the method in detail, as Ritz presented it, and as Rayleigh claimed to have used it. It concludes that, although Rayleigh did solve a few problems which involved minimization of a frequency, these solutions were not by the straightforward, direct method presented by Ritz and used subsequently by others. Therefore, Rayleigh's name should not be attached to the method.
Wang, Zhitao; Fang, Liang; Shi, Wenjing; Wang, Kexiong; Wang, Ding
2013-04-01
Broadband recording systems were adapted to characterize the whistle characteristics of free-ranging Indo-Pacific humpback dolphins (Sousa chinensis) in Sanniang Bay, China. A total of 4630 whistles were recorded, of which 2651 with legible contours and relatively good signal-to-noise ratios were selected for statistical analysis. Of the six tonal types (i.e., flat, down, rise, convex, U-shaped, and sine), flat (N = 1426; 39.45%) was the most predominant, followed by down (N = 754; 23.35%) and rise (N = 489; 12.34%). The whistles showed a short duration (mean ± SD: 370.19 ± 285.61 ms; range: 29-2923 ms), a broad frequency range (fundamental contour ranged from 0.52 to 33 kHz), and two harmonics (mean ± SD: 1.90 ± 2.74, with the maximum frequency of harmonics beyond 96 kHz). Whistles without gaps and stairs accounted for 76.7% and 86.4%, respectively. No significant interspecies differences in frequency parameters were observed compared with S. teuszii, which is inconsistent with morphological taxonomies but confirms phylogenetic results, thus suggesting a close relation between Chinese S. chinensis and Atlantic S. teuszii. Significant intra- and interspecific differences in the genus Sousa were also observed, indicating that animal vocalization may not be limited by genetically determined traits but could also be a function of local habitat adaptation.
NASA Astrophysics Data System (ADS)
Ghasemi, F.; Abbasi Davani, F.
2015-06-01
Due to Iran's growing need for accelerators in various applications, IPM's electron Linac project has been defined. This accelerator is a 15 MeV energy S-band traveling-wave accelerator which is being designed and constructed based on the klystron that has been built in Iran. Based on the design, operating mode is π /2 and the accelerating chamber consists of two 60cm long tubes with constant impedance and a 30cm long buncher. Amongst all construction methods, shrinking method is selected for construction of IPM's electron Linac tube because it has a simple procedure and there is no need for large vacuum or hydrogen furnaces. In this paper, different aspects of this method are investigated. According to the calculations, linear ratio of frequency alteration to radius change is 787.8 MHz/cm, and the maximum deformation at the tube wall where disks and the tube make contact is 2.7μ m. Applying shrinking method for construction of 8- and 24-cavity tubes results in satisfactory frequency and quality factor. Average deviations of cavities frequency of 8- and 24-cavity tubes to the design values are 0.68 MHz and 1.8 MHz respectively before tune and 0.2 MHz and 0.4 MHz after tune. Accelerating tubes, buncher, and high power couplers of IPM's electron linac are constructed using shrinking method.
Astronomical reach of fundamental physics.
Burrows, Adam S; Ostriker, Jeremiah P
2014-02-18
Using basic physical arguments, we derive by dimensional and physical analysis the characteristic masses and sizes of important objects in the universe in terms of just a few fundamental constants. This exercise illustrates the unifying power of physics and the profound connections between the small and the large in the cosmos we inhabit. We focus on the minimum and maximum masses of normal stars, the corresponding quantities for neutron stars, the maximum mass of a rocky planet, the maximum mass of a white dwarf, and the mass of a typical galaxy. To zeroth order, we show that all these masses can be expressed in terms of either the Planck mass or the Chandrasekar mass, in combination with various dimensionless quantities. With these examples, we expose the deep interrelationships imposed by nature between disparate realms of the universe and the amazing consequences of the unifying character of physical law.
The association between motor skill competence and physical fitness in young adults.
Stodden, David; Langendorfer, Stephen; Roberton, Mary Ann
2009-06-01
We examined the relationship between competence in three fundamental motor skills (throwing kicking, and jumping) and six measures of health-related physical fitness in young adults (ages 18-25). We assessed motor skill competence using product scores of maximum kicking and throwing speed and maximum jumping distance. A factor analysis indicated the 12-min run/walk, percent body fat, curl-ups, grip strength, and maximum leg press strength all loaded on one factor defining the construct of "overall fitness. "Multiple regression analyses indicated that the product scores for jumping (74%), kicking (58%), and throwing (59%) predicted 79% of the variance in overall fitness. Gender was not a significant predictor of fitness. Results suggest that developing motor skill competence may be fundamental in developing and maintaining adequate physical fitness into adulthood. These data represent the strongest to date on the relationship between motor skill competence and physical fitness.
Astronomical reach of fundamental physics
Burrows, Adam S.; Ostriker, Jeremiah P.
2014-01-01
Using basic physical arguments, we derive by dimensional and physical analysis the characteristic masses and sizes of important objects in the universe in terms of just a few fundamental constants. This exercise illustrates the unifying power of physics and the profound connections between the small and the large in the cosmos we inhabit. We focus on the minimum and maximum masses of normal stars, the corresponding quantities for neutron stars, the maximum mass of a rocky planet, the maximum mass of a white dwarf, and the mass of a typical galaxy. To zeroth order, we show that all these masses can be expressed in terms of either the Planck mass or the Chandrasekar mass, in combination with various dimensionless quantities. With these examples, we expose the deep interrelationships imposed by nature between disparate realms of the universe and the amazing consequences of the unifying character of physical law. PMID:24477692
The origin of SH-wave resonance frequencies in sedimentary layers
NASA Astrophysics Data System (ADS)
van der Baan, Mirko
2009-09-01
Resonance frequencies are often analysed in geo-engineering studies to evaluate seismic risk and microzonation in urban areas. The Nakamura technique constitutes a popular approach that computes the spectral ratio of horizontal-to-vertical ground motion in ambient noise recordings to reveal the existence of any site resonance frequencies. Its theoretical basis remains however unclear with some authors arguing that the method de-emphasizes any Rayleigh-wave contributions and that the resonance frequencies are solely caused by vertically incident SH waves. Other authors explain the same resonance frequencies by the ellipticity of the fundamental Rayleigh wave. Recent numerical simulations reveal that the magnitude of the peak frequency is proportional to the relative portion of Love waves present. This study demonstrates that Love waves alone can be responsible for any observed resonance frequencies in sedimentary layers. Yet sharp SH-wave resonance frequencies are only excited by a source in the bedrock. These resonance frequencies are caused by inhomogeneous waves excited by the bedrock source that tunnel through the high-velocity bedrock to emerge in the low-velocity sediments with a very reduced range of slownesses. The resulting SH waves are then free to interfere constructively thereby creating the observed resonance frequencies. This general trigger mechanism leads to resonances that are almost offset independent. The resulting resonance frequencies map onto points of maximum curvature in the Love-wave phase-velocity dispersion curves at or just beyond the critical horizontal slowness. They can be analysed with the quarter-wavelength law if a large velocity contrast exists between the unconsolidated sediments and the bedrock. A minor modification of the quarter-wavelength law provides more accurate predictions, also for smaller velocity contrasts. Multisource simulations show that site amplification factors as determined by horizontal-over-vertical (H/V) spectral ratios would not only depend on the relative portion of Love waves in the total wavefield but also on the depth distribution and the relative strength of the SH sources inside the bedrock compared with those in the sediments. An accurate interpretation of site amplification factors by means of H/V peak frequencies would thus require in-depth knowledge of the causes and origins of the local microseismic noise field.
RIEDE, TOBIAS
2014-01-01
Rodents produce highly variable ultrasound whistles as communication signals unlike many other mammals, who employ flow-induced vocal fold oscillations to produce sound. The role of larynx muscles in controlling sound features across different call types in ultrasound vocalization (USV) was investigated using laryngeal muscle electromyographic (EMG) activity, subglottal pressure measurements and vocal sound output in awake and spontaneously behaving Sprague–Dawley rats. Results support the hypothesis that glottal shape determines fundamental frequency. EMG activities of thyroarytenoid and cricothyroid muscles were aligned with call duration. EMG intensity increased with fundamental frequency. Phasic activities of both muscles were aligned with fast changing fundamental frequency contours, for example in trills. Activities of the sternothyroid and sternohyoid muscles, two muscles involved in vocal production in other mammals, are not critical for the production of rat USV. To test how stereotypic laryngeal and respiratory activity are across call types and individuals, sets of ten EMG and subglottal pressure parameters were measured in six different call types from six rats. Using discriminant function analysis, on average 80% of parameter sets were correctly assigned to their respective call type. This was significantly higher than the chance level. Since fundamental frequency features of USV are tightly associated with stereotypic activity of intrinsic laryngeal muscles and muscles contributing to build-up of subglottal pressure, USV provide insight into the neurophysiological control of peripheral vocal motor patterns. PMID:23423862
Broadband seismic noise attenuation versus depth at the Albuquerque Seismological Laboratory
Hutt, Charles R.; Ringler, Adam; Gee, Lind
2017-01-01
Seismic noise induced by atmospheric processes such as wind and pressure changes can be a major contributor to the background noise observed in many seismograph stations, especially those installed at or near the surface. Cultural noise such as vehicle traffic or nearby buildings with air handling equipment also contributes to seismic background noise. Such noise sources fundamentally limit our ability to resolve earthquake‐generated signals. Many previous seismic noise versus depth studies focused separately on either high‐frequency (>1 Hz">>1 Hz) or low‐frequency (<0.05 Hz"><0.05 Hz) bands. In this study, we use modern high‐quality broadband (BB) and very broadband (VBB) seismometers installed at depths ranging from 1.5 to 188 m at the Albuquerque Seismological Laboratory to evaluate noise attenuation as a function of depth over a broad range of frequencies (0.002–50 Hz). Many modern seismometer deployments use BB or VBB seismometers installed at various depths, depending on the application. These depths range from one‐half meter or less in aftershock study deployments, to one or two meters in the Incorporated Research Institutions for Seismology Transportable Array (TA), to a few meters (shallow surface vaults) up to 100 m or more (boreholes) in the permanent observatories of the Global Seismographic Network (GSN). It is important for managers and planners of these and similar arrays and networks of seismograph stations to understand the attenuation of surface‐generated noise versus depth so that they can achieve desired performance goals within their budgets as well as their frequency band of focus. The results of this study will assist in decisions regarding BB and VBB seismometer installation depths. In general, we find that greater installation depths are better and seismometer emplacement in hard rock is better than in soil. Attenuation for any given depth varies with frequency. More specifically, we find that the dependence of depth will be application dependent based on the frequency band and sensitive axes of interest. For quick deployments (like aftershock studies), 1 m may be deep enough to produce good data, especially when the focus is on vertical data where temperature stability fundamentally limits the low‐frequency noise levels and little low‐frequency data will be used. For temporary (medium‐term) deployments (e.g., TA) where low cost can be very important, 2–3 m should be sufficient, but such shallow installations will limit the ability to resolve low‐frequency signals, especially on horizontal components. Of course, one should try for maximum burial depth within the budget when there is interest in using the data for low‐frequency applications. For long‐term deployments like the permanent observatories of the GSN and similar networks, 100–200 m depth in hard rock is desirable to achieve lowest noise, although 30–60 m may be acceptable.
Yunusova, Yana; Wang, Jun; Zinman, Lorne; Pattee, Gary L.; Berry, James D.; Perry, Bridget; Green, Jordan R.
2016-01-01
Purpose To determine the mechanisms of speech intelligibility impairment due to neurologic impairments, intelligibility decline was modeled as a function of co-occurring changes in the articulatory, resonatory, phonatory, and respiratory subsystems. Method Sixty-six individuals diagnosed with amyotrophic lateral sclerosis (ALS) were studied longitudinally. The disease-related changes in articulatory, resonatory, phonatory, and respiratory subsystems were quantified using multiple instrumental measures, which were subjected to a principal component analysis and mixed effects models to derive a set of speech subsystem predictors. A stepwise approach was used to select the best set of subsystem predictors to model the overall decline in intelligibility. Results Intelligibility was modeled as a function of five predictors that corresponded to velocities of lip and jaw movements (articulatory), number of syllable repetitions in the alternating motion rate task (articulatory), nasal airflow (resonatory), maximum fundamental frequency (phonatory), and speech pauses (respiratory). The model accounted for 95.6% of the variance in intelligibility, among which the articulatory predictors showed the most substantial independent contribution (57.7%). Conclusion Articulatory impairments characterized by reduced velocities of lip and jaw movements and resonatory impairments characterized by increased nasal airflow served as the subsystem predictors of the longitudinal decline of speech intelligibility in ALS. Declines in maximum performance tasks such as the alternating motion rate preceded declines in intelligibility, thus serving as early predictors of bulbar dysfunction. Following the rapid decline in speech intelligibility, a precipitous decline in maximum performance tasks subsequently occurred. PMID:27148967
Rong, Panying; Yunusova, Yana; Wang, Jun; Zinman, Lorne; Pattee, Gary L; Berry, James D; Perry, Bridget; Green, Jordan R
2016-01-01
To determine the mechanisms of speech intelligibility impairment due to neurologic impairments, intelligibility decline was modeled as a function of co-occurring changes in the articulatory, resonatory, phonatory, and respiratory subsystems. Sixty-six individuals diagnosed with amyotrophic lateral sclerosis (ALS) were studied longitudinally. The disease-related changes in articulatory, resonatory, phonatory, and respiratory subsystems were quantified using multiple instrumental measures, which were subjected to a principal component analysis and mixed effects models to derive a set of speech subsystem predictors. A stepwise approach was used to select the best set of subsystem predictors to model the overall decline in intelligibility. Intelligibility was modeled as a function of five predictors that corresponded to velocities of lip and jaw movements (articulatory), number of syllable repetitions in the alternating motion rate task (articulatory), nasal airflow (resonatory), maximum fundamental frequency (phonatory), and speech pauses (respiratory). The model accounted for 95.6% of the variance in intelligibility, among which the articulatory predictors showed the most substantial independent contribution (57.7%). Articulatory impairments characterized by reduced velocities of lip and jaw movements and resonatory impairments characterized by increased nasal airflow served as the subsystem predictors of the longitudinal decline of speech intelligibility in ALS. Declines in maximum performance tasks such as the alternating motion rate preceded declines in intelligibility, thus serving as early predictors of bulbar dysfunction. Following the rapid decline in speech intelligibility, a precipitous decline in maximum performance tasks subsequently occurred.
The Association between Motor Skill Competence and Physical Fitness in Young Adults
ERIC Educational Resources Information Center
Stodden, David; Langendorfer, Stephen; Roberton, Mary Ann
2009-01-01
We examined the relationship between competence in three fundamental motor skills (throwing, kicking, and jumping) and six measures of health-related physical fitness in young adults (ages 18-25). We assessed motor skill competence using product scores of maximum kicking and throwing speed and maximum jumping distance. A factor analysis indicated…
Kam, Chon-Fai; Liu, Ren-Bao
2017-08-29
Berry phases and gauge structures are fundamental quantum phenomena. In linear quantum mechanics the gauge field in parameter space presents monopole singularities where the energy levels become degenerate. In nonlinear quantum mechanics, which is an effective theory of interacting quantum systems, there can be phase transitions and hence critical surfaces in the parameter space. We find that these critical surfaces result in a new type of gauge field singularity, namely, a conic singularity that resembles the big bang of a 2 + 1 dimensional de Sitter universe, with the fundamental frequency of Bogoliubov excitations acting as the cosmic scale, and mode softening at the critical surface, where the fundamental frequency vanishes, causing a causal singularity. Such conic singularity may be observed in various systems such as Bose-Einstein condensates and molecular magnets. This finding offers a new approach to quantum simulation of fundamental physics.
Three-month-old human infants use vocal cues of body size.
Pietraszewski, David; Wertz, Annie E; Bryant, Gregory A; Wynn, Karen
2017-06-14
Differences in vocal fundamental ( F 0 ) and average formant ( F n ) frequencies covary with body size in most terrestrial mammals, such that larger organisms tend to produce lower frequency sounds than smaller organisms, both between species and also across different sex and life-stage morphs within species. Here we examined whether three-month-old human infants are sensitive to the relationship between body size and sound frequencies. Using a violation-of-expectation paradigm, we found that infants looked longer at stimuli inconsistent with the relationship-that is, a smaller organism producing lower frequency sounds, and a larger organism producing higher frequency sounds-than at stimuli that were consistent with it. This effect was stronger for fundamental frequency than it was for average formant frequency. These results suggest that by three months of age, human infants are already sensitive to the biologically relevant covariation between vocalization frequencies and visual cues to body size. This ability may be a consequence of developmental adaptations for building a phenotype capable of identifying and representing an organism's size, sex and life-stage. © 2017 The Author(s).
Nguyen, Tanya T.; Ashrafi, Ashkan; Thomas, Jennifer D.; Riley, Edward P.; Simmons, Roger W.
2013-01-01
To extend our current understanding of the teratogenic effects of prenatal alcohol exposure on the control of isometric force, the present study investigated the signal characteristics of power spectral density functions resulting from sustained control of isometric force by children with and without heavy prenatal exposure to alcohol. It was predicted that the functions associated with the force signals would be fundamentally different for the two groups. Twenty-five children aged between 7 and 17 years with heavy prenatal alcohol exposure and 21 non-alcohol exposed control children attempted to duplicate a visually represented target force by pressing on a load cell. The level of target force (5 and 20% of maximum voluntary contraction) and the time interval between visual feedback (20ms, 320ms and 740ms) were manipulated. A multivariate spectral estimation method with sinusoidal windows was applied to individual isometric force-time signals. Analysis of the resulting power spectral density functions revealed that the alcohol-exposed children had a lower mean frequency, less spectral variability, greater peak power and a lower frequency at which peak power occurred. Furthermore, mean frequency and spectral variability produced by the alcohol-exposed group remained constant across target load and visual feedback interval, suggesting that these children were limited to making long-time scale corrections to the force signal. In contrast, the control group produced decreased mean frequency and spectral variability as target force and the interval between visual feedback increased, indicating that when feedback was frequently presented these children used the information to make short-time scale adjustments to the ongoing force signal. Knowledge of these differences could facilitate the design of motor rehabilitation exercises that specifically target isometric force control deficits in alcohol-exposed children. PMID:23238099
Improved MIMO radar GMTI via cyclic-shift transmission of orthogonal frequency division signals
NASA Astrophysics Data System (ADS)
Li, Fuyou; He, Feng; Dong, Zhen; Wu, Manqing
2018-05-01
Minimum detectable velocity (MDV) and maximum detectable velocity are both important in ground moving target indication (GMTI) systems. Smaller MDV can be achieved by longer baseline via multiple-input multiple-output (MIMO) radar. Maximum detectable velocity is decided by blind velocities associated with carrier frequencies, and blind velocities can be mitigated by orthogonal frequency division signals. However, the scattering echoes from different carrier frequencies are independent, which is not good for improving MDV performance. An improved cyclic-shift transmission is applied in MIMO GMTI system in this paper. MDV performance is improved due to the longer baseline, and maximum detectable velocity performance is improved due to the mitigation of blind velocities via multiple carrier frequencies. The signal model for this mode is established, the principle of mitigating blind velocities with orthogonal frequency division signals is presented; the performance of different MIMO GMTI waveforms is analysed; and the performance of different array configurations is analysed. Simulation results by space-time-frequency adaptive processing proves that our proposed method is a valid way to improve GMTI performance.
Tidal frequency estimation for closed basins
NASA Technical Reports Server (NTRS)
Eades, J. B., Jr.
1978-01-01
A method was developed for determining the fundamental tidal frequencies for closed basins of water, by means of an eigenvalue analysis. The mathematical model employed, was the Laplace tidal equations.
Conference Digest LEOS Summer Topical Meetings 1992
1992-12-09
of the circuit and determines the maximum frequency of operation. With...operating at a frequency of 335.48 MHz. The resultant timing jitter is determined by sending both pulse trains into a rotating mirror optical correlator with...length of 1.5 un and a gate width of 100 um. have a maximum transconductance of 160 mS/mm and a cut-off frequency of 10 GHz. To determine the
Frequency characteristics of standing-wave acoustooptic modulators
NASA Astrophysics Data System (ADS)
Apolonskii, A. A.; Shchebetov, S. D.
1991-10-01
Experimental data are presented on the performance of wide-aperture standing-wave acoustooptic modulators used as laser mode lockers. In particular, attention is given to the acoustooptic and electrical frequency characteristics of the modulators. The existence of a large effective diffraction frequency region below the fundamental frequency is demonstrated. Individual frequency regions of effective diffraction do not correspond to the even and odd harmonics.
Dmitrieva, E S; Gel'man, V Ia; Zaĭtseva, K A; Orlov, A M
2009-01-01
Comparative study of acoustic correlates of emotional intonation was conducted on two types of speech material: sensible speech utterances and short meaningless words. The corpus of speech signals of different emotional intonations (happy, angry, frightened, sad and neutral) was created using the actor's method of simulation of emotions. Native Russian 20-70-year-old speakers (both professional actors and non-actors) participated in the study. In the corpus, the following characteristics were analyzed: mean values and standard deviations of the power, fundamental frequency, frequencies of the first and second formants, and utterance duration. Comparison of each emotional intonation with "neutral" utterances showed the greatest deviations of the fundamental frequency and frequencies of the first formant. The direction of these deviations was independent of the semantic content of speech utterance and its duration, age, gender, and being actor or non-actor, though the personal features of the speakers affected the absolute values of these frequencies.
Experimenting with musical intervals
NASA Astrophysics Data System (ADS)
Lo Presto, Michael C.
2003-07-01
When two tuning forks of different frequency are sounded simultaneously the result is a complex wave with a repetition frequency that is the fundamental of the harmonic series to which both frequencies belong. The ear perceives this 'musical interval' as a single musical pitch with a sound quality produced by the harmonic spectrum responsible for the waveform. This waveform can be captured and displayed with data collection hardware and software. The fundamental frequency can then be calculated and compared with what would be expected from the frequencies of the tuning forks. Also, graphing software can be used to determine equations for the waveforms and predict their shapes. This experiment could be used in an introductory physics or musical acoustics course as a practical lesson in superposition of waves, basic Fourier series and the relationship between some of the ear's subjective perceptions of sound and the physical properties of the waves that cause them.
NASA Astrophysics Data System (ADS)
Mussio, P.; Gnyp, A. W.; Henshaw, P. F.
A fluctuating plume dispersion model has been developed to facilitate the prediction of odour-impact frequencies in the communities surrounding elevated point sources. The model was used to predict the frequencies of occurrence of odours of various magnitudes for 1 h periods. In addition, the model predicted the maximum odour level. The model was tested with an extensive set of data collected in the residential areas surrounding the paint shop of an automotive assembly plant. Most of the perceived odours in the vicinity of the 64, 46 m high stacks ranged between 2 and 7 odour units and generally persisted for less than 30 s. Ninety-eight different field determinations of odour impact frequencies within 1 km of the plant were conducted during the course of the study. To simplify evaluation, the frequencies of occurrence of different odour levels were summed to give the total frequency of occurrence of all readily detectable (>2 OU) odours. The model provided excellent simulation of the total frequencies of occurrence where the odour was frequent (i.e . readily detectable more than 30% of the time). At lower frequencies of occurrence the model prediction was poor. The stability class did not seem to affect the model's ability to predict field frequency values. However, the model provided excellent predictions of the maximum odour levels without being sensitive to either stability class or distance from the source. Ninety-five percent of the predicted maximum values were within a factor of two of the measured field maximum values.
An Assessment of the State-of-the-Art in Multidisciplinary Aeromechanical Analyses
2008-01-01
monolithic formulations. In summary, for aerospace structures, partitioned formulations provide fundamental advantages over fully coupled ones, in addition...important frequencies of local analysis directly to global analysis using detailed modeling. Performed ju- diciously, based on a fundamental understanding of...in 2000 has com- prehensively described the problem, and reviewed the status of fundamental understanding, experimental data, and analytical
An examination of the spectral class low frequency limit for helicopters
DOT National Transportation Integrated Search
2011-01-01
Currently, INM and AEDT do not use spectral data below 50 Hz in their noise computations. However, helicopter rotor rotational noise is dominant below 50Hz, with a fundamental frequency at the blade-pass frequency (BPF) and harmonics at integer multi...
Auffhammer, Maximilian; Baylis, Patrick; Hausman, Catherine H
2017-02-21
It has been suggested that climate change impacts on the electric sector will account for the majority of global economic damages by the end of the current century and beyond [Rose S, et al. (2014) Understanding the Social Cost of Carbon: A Technical Assessment ]. The empirical literature has shown significant increases in climate-driven impacts on overall consumption, yet has not focused on the cost implications of the increased intensity and frequency of extreme events driving peak demand, which is the highest load observed in a period. We use comprehensive, high-frequency data at the level of load balancing authorities to parameterize the relationship between average or peak electricity demand and temperature for a major economy. Using statistical models, we analyze multiyear data from 166 load balancing authorities in the United States. We couple the estimated temperature response functions for total daily consumption and daily peak load with 18 downscaled global climate models (GCMs) to simulate climate change-driven impacts on both outcomes. We show moderate and heterogeneous changes in consumption, with an average increase of 2.8% by end of century. The results of our peak load simulations, however, suggest significant increases in the intensity and frequency of peak events throughout the United States, assuming today's technology and electricity market fundamentals. As the electricity grid is built to endure maximum load, our findings have significant implications for the construction of costly peak generating capacity, suggesting additional peak capacity costs of up to 180 billion dollars by the end of the century under business-as-usual.
Computational studies for a multiple-frequency electron cyclotron resonance ion source (abstract)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alton, G.D.
1996-03-01
The number density of electrons, the energy (electron temperature), and energy distribution are three of the fundamental properties which govern the performance of electron cyclotron resonance (ECR) ion sources in terms of their capability to produce high charge state ions. The maximum electron energy is affected by several processes including the ability of the plasma to absorb power. In principle, the performances of an ECR ion source can be realized by increasing the physical size of the ECR zone in relation to the total plasma volume. The ECR zones can be increased either in the spatial or frequency domains inmore » any ECR ion source based on B-minimum plasma confinement principles. The former technique requires the design of a carefully tailored magnetic field geometry so that the central region of the plasma volume is a large, uniformly distributed plasma volume which surrounds the axis of symmetry, as proposed in Ref. . Present art forms of the ECR source utilize single frequency microwave power supplies to maintain the plasma discharge; because the magnetic field distribution continually changes in this source design, the ECR zones are relegated to thin {open_quote}{open_quote}surfaces{close_quote}{close_quote} which surround the axis of symmetry. As a consequence of the small ECR zone in relation to the total plasma volume, the probability for stochastic heating of the electrons is quite low, thereby compromising the source performance. This handicap can be overcome by use of broadband, multiple frequency microwave power as evidenced by the enhanced performances of the CAPRICE and AECR ion sources when two frequency microwave power was utilized. We have used particle-in-cell codes to simulate the magnetic field distributions in these sources and to demonstrate the advantages of using multiple, discrete frequencies over single frequencies to power conventional ECR ion sources. (Abstract Truncated)« less
Grain refinement control in TIG arc welding
NASA Technical Reports Server (NTRS)
Iceland, W. F.; Whiffen, E. L. (Inventor)
1975-01-01
A method for controlling grain size and weld puddle agitation in a tungsten electrode inert gas welding system to produce fine, even grain size and distribution is disclosed. In the method the frequency of dc welding voltage pulses supplied to the welding electrode is varied over a preselected frequency range and the arc gas voltage is monitored. At some frequency in the preselected range the arc gas voltage will pass through a maximum. By maintaining the operating frequency of the system at this value, maximum weld puddle agitation and fine grain structure are produced.
A new insight into the oscillation characteristics of endosonic files used in dentistry.
Lea, S C; Walmsley, A D; Lumley, P J; Landini, G
2004-05-21
The aim of this study was to assess the oscillation characteristics of unconstrained endosonic files using a scanning laser vibrometer (SLV). Factors investigated included file vibration frequency and node/antinode location as well as the variation in file displacement amplitude due to increasing generator power setting. A 30 kHz Mini Piezon generator (Electro-Medical Systems, Switzerland) was used in conjunction with a #15 and #35 K-file. Each file was fixed in position with the long axis of the file perpendicular to the SLV camera head. The laser from the SLV was scanned over the length of the oscillating file for generator power settings 1 to 5 (minimum to half power). Measurements were repeated ten times. The fundamental vibration frequency for both files was 27.50 kHz. Scans of each file showed the positions of nodes/anti-nodes along the file length. The #15 file demonstrated no significant variation in its mean maximum displacement amplitude with increasing generator power, except at power setting 5, where a decrease in displacement amplitude was observed. The #35 file showed a general increase in mean maximum displacement amplitude with increasing power setting, except at power setting 4 where a 65% decrease in displacement amplitude occurred. In conclusion, scanning laser vibrometry is an effective method for assessing endosonic file vibration characteristics. The SLV was able to demonstrate that (unloaded) file vibration displacement amplitude does not increase linearly with increasing generator power. Further work is being performed on a greater variety of files and generators. Vibration characteristics of files under various loads and varying degrees of constraint should also be investigated.
NASA Astrophysics Data System (ADS)
Pintér, Balázs; Erdélyi, R.
2018-01-01
Solar fundamental (f) acoustic mode oscillations are investigated analytically in a magnetohydrodynamic (MHD) model. The model consists of three layers in planar geometry, representing the solar interior, the magnetic atmosphere, and a transitional layer sandwiched between them. Since we focus on the fundamental mode here, we assume the plasma is incompressible. A horizontal, canopy-like, magnetic field is introduced to the atmosphere, in which degenerated slow MHD waves can exist. The global (f-mode) oscillations can couple to local atmospheric Alfvén waves, resulting, e.g., in a frequency shift of the oscillations. The dispersion relation of the global oscillation mode is derived, and is solved analytically for the thin-transitional layer approximation and for the weak-field approximation. Analytical formulae are also provided for the frequency shifts due to the presence of a thin transitional layer and a weak atmospheric magnetic field. The analytical results generally indicate that, compared to the fundamental value (ω =√{ gk }), the mode frequency is reduced by the presence of an atmosphere by a few per cent. A thin transitional layer reduces the eigen-frequencies further by about an additional hundred microhertz. Finally, a weak atmospheric magnetic field can slightly, by a few percent, increase the frequency of the eigen-mode. Stronger magnetic fields, however, can increase the f-mode frequency by even up to ten per cent, which cannot be seen in observed data. The presence of a magnetic atmosphere in the three-layer model also introduces non-permitted propagation windows in the frequency spectrum; here, f-mode oscillations cannot exist with certain values of the harmonic degree. The eigen-frequencies can be sensitive to the background physical parameters, such as an atmospheric density scale-height or the rate of the plasma density drop at the photosphere. Such information, if ever observed with high-resolution instrumentation and inverted, could help to gain further insight into solar magnetic structures by means of solar magneto-seismology, and could provide further insight into the role of magnetism in solar oscillations.
Improving Understanding of Emotional Speech Acoustic Content
NASA Astrophysics Data System (ADS)
Tinnemore, Anna
Children with cochlear implants show deficits in identifying emotional intent of utterances without facial or body language cues. A known limitation to cochlear implants is the inability to accurately portray the fundamental frequency contour of speech which carries the majority of information needed to identify emotional intent. Without reliable access to the fundamental frequency, other methods of identifying vocal emotion, if identifiable, could be used to guide therapies for training children with cochlear implants to better identify vocal emotion. The current study analyzed recordings of adults speaking neutral sentences with a set array of emotions in a child-directed and adult-directed manner. The goal was to identify acoustic cues that contribute to emotion identification that may be enhanced in child-directed speech, but are also present in adult-directed speech. Results of this study showed that there were significant differences in the variation of the fundamental frequency, the variation of intensity, and the rate of speech among emotions and between intended audiences.
Glottal flow through a two-mass model: comparison of Navier-Stokes solutions with simplified models.
de Vries, M P; Schutte, H K; Veldman, A E P; Verkerke, G J
2002-04-01
A new numerical model of the vocal folds is presented based on the well-known two-mass models of the vocal folds. The two-mass model is coupled to a model of glottal airflow based on the incompressible Navier-Stokes equations. Glottal waves are produced using different initial glottal gaps and different subglottal pressures. Fundamental frequency, glottal peak flow, and closed phase of the glottal waves have been compared with values known from the literature. The phonation threshold pressure was determined for different initial glottal gaps. The phonation threshold pressure obtained using the flow model with Navier-Stokes equations corresponds better to values determined in normal phonation than the phonation threshold pressure obtained using the flow model based on the Bernoulli equation. Using the Navier-Stokes equations, an increase of the subglottal pressure causes the fundamental frequency and the glottal peak flow to increase, whereas the fundamental frequency in the Bernoulli-based model does not change with increasing pressure.
Method and device for identifying different species of honeybees
Kerr, Howard T.; Buchanan, Michael E.; Valentine, Kenneth H.
1989-01-01
A method and device have been provided for distinguishing Africanized honeybees from European honeybees. The method is based on the discovery of a distinct difference in the acoustical signatures of these two species of honeybees in flight. The European honeybee signature has a fundamental power peak in the 210 to 240 Hz range while the Africanized honeybee signature has a fundamental power peak in the 260 to 290 Hz range. The acoustic signal produced by honeybees is analyzed by means of a detecting device to quickly determine the honeybee species through the detection of the presence of frequencies in one of these distinct ranges. The device includes a microphone for acoustical signal detection which feeds the detected signal into a frequency analyzer which is designed to detect the presence of either of the known fundamental wingbeat frequencies unique to the acoustical signatures of these species as an indication of the identity of the species and indicate the species identity on a readout device.
Baker, F; Wigram, T; Gold, C
2005-07-01
To examine changes in the relationship between intonation, voice range and mood following music therapy programmes in people with traumatic brain injury. Data from four case studies were pooled and effect size, ANOVA and correlation calculations were performed to evaluate the effectiveness of treatment. Subjects sang three self-selected songs for 15 sessions. Speaking fundamental frequency, fundamental frequency variability, slope, voice range and mood were analysed pre- and post-session. Immediate treatment effects were not found. Long-term improvements in affective intonation were found in three subjects, especially in fundamental frequency. Voice range improved over time and was positively correlated with the three intonation components. Mood scale data showed that immediate effects were in the negative direction whereas there weres increases in positive mood state in the longer-term. Findings suggest that, in the long-term, song singing can improve vocal range and mood and enhance the affective intonation styles of people with TBI.
A case study of alternative site response explanatory variables in Parkfield, California
Thompson, E.M.; Baise, L.G.; Kayen, R.E.; Morgan, E.C.; Kaklamanos, J.
2011-01-01
The combination of densely-spaced strong-motion stations in Parkfield, California, and spectral analysis of surface waves (SASW) profiles provides an ideal dataset for assessing the accuracy of different site response explanatory variables. We judge accuracy in terms of spatial coverage and correlation with observations. The performance of the alternative models is period-dependent, but generally we observe that: (1) where a profile is available, the square-root-of-impedance method outperforms VS30 (average S-wave velocity to 30 m depth), and (2) where a profile is unavailable, the topographic-slope method outperforms surficial geology. The fundamental site frequency is a valuable site response explanatory variable, though less valuable than VS30. However, given the expense and difficulty of obtaining reliable estimates of VS30 and the relative ease with which the fundamental site frequency can be computed, the fundamental site frequency may prove to be a valuable site response explanatory variable for many applications. ?? 2011 ASCE.
Transient regime in second harmonic generation
NASA Astrophysics Data System (ADS)
Szeftel, Jacob; Sandeau, Laure; Sandeau, Nicolas; Delezoide, Camille; Khater, Antoine
2013-09-01
The time growth of the electromagnetic field at the fundamental and double frequencies is studied from the very onset of the second harmonic generation (SHG) process for a set of dipoles lacking a symmetry centre and exhibiting a nonresonant coupling with a classical electromagnetic field. This approach consists first of solving the Schrödinger equation by applying a generalised Rabi rotation to the Hamiltonian describing the light-dipole interaction. This rotation has been devised for the resulting Hamiltonian to show up time-independent for both components of the electromagnetic field at the fundamental frequency and the second harmonic one. Then an energy conservation argument, derived from the Poynting theorem, is introduced to work out an additional relationship between the electromagnetic field and its associated electric polarisation. Finally this analysis yields the full time behaviour of all physical quantities of interest. The calculated results reproduce accurately both the observed spatial oscillations of the SHG intensity (Maker's fringes) and its power law dependence on the intensity of the incoming light at the fundamental frequency.
Testing a model of intonation in a tone language.
Lindau, M
1986-09-01
Schematic fundamental frequency curves of simple statements and questions are generated for Hausa, a two-tone language of Nigeria, using a modified version of an intonational model developed by Gårding and Bruce [Nordic Prosody II, edited by T. Fretheim (Tapir, Trondheim, 1981), pp. 33-39]. In this model, rules for intonation and tones are separated. Intonation is represented as sloping grids of (near) parallel lines, inside which tones are placed. The tones are associated with turning points of the fundamental frequency contour. Local rules may also modify the exact placement of a tone within the grid. The continuous fundamental frequency contour is modeled by concatenating the tonal points using polynomial equations. Thus the final pitch contour is modeled as an interaction between global and local factors. The slope of the intonational grid lines depends at least on sentence type (statement or question), sentence length, and tone pattern. The model is tested by reference to data from nine speakers of Kano Hausa.
Vibration characteristics of a deployable controllable-geometry truss boom
NASA Technical Reports Server (NTRS)
Dorsey, J. T.
1983-01-01
An analytical study was made to evaluate changes in the fundamental frequency of a two dimensional cantilevered truss boom at various stages of deployment. The truss could be axially deployed or retracted and undergo a variety of controlled geometry changes by shortening or lengthening the telescoping diagonal members in each bay. Both untapered and tapered versions of the truss boom were modeled and analyzed by using the finite element method. Large reductions in fundamental frequency occurred for both the untapered and tapered trusses when they were uniformly retracted or maneuvered laterally from their fully deployed position. These frequency reductions can be minimized, however, if truss geometries are selected which maintain cantilever root stiffness during truss maneuvers.
Evaluation of local site effect from microtremor measurements in Babol City, Iran
NASA Astrophysics Data System (ADS)
Rezaei, Sadegh; Choobbasti, Asskar Janalizadeh
2018-03-01
Every year, numerous casualties and a large deal of financial losses are incurred due to earthquake events. The losses incurred by an earthquake vary depending on local site effect. Therefore, in order to conquer drastic effects of an earthquake, one should evaluate urban districts in terms of the local site effect. One of the methods for evaluating the local site effect is microtremor measurement and analysis. Aiming at evaluation of local site effect across the city of Babol, the study area was gridded and microtremor measurements were performed with an appropriate distribution. The acquired data was analyzed through the horizontal-to-vertical noise ratio (HVNR) method, and fundamental frequency and associated amplitude of the H/V peak were obtained. The results indicate that fundamental frequency of the study area is generally lower than 1.25 Hz, which is acceptably in agreement with the findings of previous studies. Also, in order to constrain and validate the seismostratigraphic model obtained with this method, the results were compared with geotechnical, geological, and seismic data. Comparing the results of different methods, it was observed that the presented geophysical method can successfully determine the values of fundamental frequency across the study area as well as local site effect. Using the data obtained from the analysis of microtremor, a microzonation map of fundamental frequency across the city of Babol was prepared. This map has numerous applications in designing high-rise building and urban development plans.
Gender differences in children's voice use in a day care environment.
Nygren, Mariana; Tyboni, Mikaela; Lindström, Fredric; McAllister, Anita; van Doorn, Jan
2012-11-01
The prevalence of dysphonia is higher in boys than in girls before puberty. This could be because of the differences in boys' and girls' voice use. Previous research on gender differences in prepubescent children's voice parameters has been contradictory. Most studies have focused on examining fundamental frequency. The purpose of this study was to investigate voice use in boys and girls in a day care environment based on the voice parameters fundamental frequency (Hz), vocal intensity (dB SPL), and phonation time (%) and to ascertain whether there were any significant gender differences. Prospective comparative design. The study was conducted in a day care environment where 30 children (17 boys and 13 girls aged 4-5 years) participated. The participants' voices were measured continuously for 4 hours with a voice accumulator that registered fundamental frequency, vocal intensity level, phonation time, and background noise. Mean (standard deviation) fundamental frequency was 310 (22) and 321 (16) Hz, vocal intensity was 93 (4) and 91 (3) dB SPL, and phonation time was 7.7 (2.0)% and 7.6 (2.5)% for boys and girls, respectively. No differences between genders were statistically significant. The finding of no statistically significant gender differences for measurements of voice parameters in a group of children aged 4-5 years in a day care environment is an important finding that contributes to increased knowledge about young boys' and girls' voice use. Copyright © 2012 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Walker, Simon; Serrano, Javier; Van Roie, Evelien
2018-04-01
Walker, S, Serrano, J, and Van Roie, E. Maximum dynamic lower-limb strength was maintained during 24-week reduced training frequency in previously sedentary older women. J Strength Cond Res 32(4): 1063-1071, 2018-There is little study into the effects of reducing strength training below the recommended twice weekly frequency, particularly in older women, despite the possibility that individuals will encounter periods of reduced training frequency. The purpose of the present study was to determine the effects of a period of reduced training frequency on maximum strength and muscle mass of the lower limbs in comparison with the recommended training frequency of twice per week. After an initial 12-week period, where all subjects trained twice per week, a reduced strength training group (RST) trained once per week, whereas another strength training group (ST) continued to train twice per week for 24 weeks. A nontraining age-matched control group (CON) was used for comparison. All subjects were tested for leg press 1-repetition maximum (1RM), electromyogram (EMG) amplitude of vastus lateralis and medialis, and quadriceps cross-sectional area (CSA) measured by panoramic ultrasound at weeks 0, 12, and 36. Both ST and RST continued to increase 1RM during the reduced training frequency period compared with control (∼8% and ∼5% vs. ∼-3%, respectively; p ≤ 0.05). Accompanying these changes were significant increases in EMG amplitude in both ST and RST (p ≤ 0.05). However, the initial gains in quadriceps CSA made from week 0 to week 12 in RST were lost when training once per week (RST ∼-5%). Therefore, reduced training frequency in this population does not adversely affect maximum strength or muscle activity but can negatively affect muscle mass, even reversing training-induced gains. Older individuals not training at least twice per week may compromise potential increases in muscle mass, important in counteracting effects of aging.
Pre-patterned ZnO nanoribbons on soft substrates for stretchable energy harvesting applications
NASA Astrophysics Data System (ADS)
Ma, Teng; Wang, Yong; Tang, Rui; Yu, Hongyu; Jiang, Hanqing
2013-05-01
Three pre-patterned ZnO nanoribbons in different configurations were studied in this paper, including (a) straight ZnO nanoribbons uniformly bonded on soft substrates that form sinusoidal buckles, (b) straight ZnO nanoribbons selectively bonded on soft substrates that form pop-up buckles, and (c) serpentine ZnO nanoribbons bonded on soft substrates via anchors. The nonlinear dynamics and random analysis were conducted to obtain the fundamental frequencies and to evaluate their performance in energy harvesting applications. We found that pop-up buckles and overhanging serpentine structures are suitable for audio frequency energy harvesting applications. Remarkably, almost unchanged fundamental natural frequency upon strain is achieved by properly patterning ZnO nanoribbons, which initiates a new and exciting direction of stretchable energy harvesting using nano-scale materials in audio frequency range.
Dependence of sound characteristics on the bowing position in a violin
NASA Astrophysics Data System (ADS)
Roh, YuJi; Kim, Young H.
2014-12-01
A quantitative analysis of violin sounds produced for different bowing positions over the full length of a violin string has been carried out. An automated bowing machine was employed in order to keep the bowing parameters constant. A 3-dimensional profile of the frequency spectrum was introduced in order to characterize the violin's sound. We found that the fundamental frequency did not change for different bowing positions, whereas the frequencies of the higher harmonics were different. Bowing the string at 30 mm from the bridge produced musical sounds. The middle of the string was confirmed to be a dead zone, as reported in previous works. In addition, the quarter position was also found to be a dead zone. Bowing the string 90 mm from the bridge dominantly produces a fundamental frequency of 864 Hz and its harmonics.
NASA Astrophysics Data System (ADS)
Ortega-Casanova, Joaquin; Fernandez-Feria, Ramon
2015-11-01
The thrust generated by two heaving plates in tandem is analysed for two particular sets of configurations of interest in forward flight: a plunging leading plate with the trailing plate at rest, and the two plates heaving with the same frequency and amplitude, but varying the phase difference. The thrust efficiency of the leading plate is augmented in relation to a single plate heaving with the same frequency and amplitude in most cases. In the first configuration, we characterize the range of nondimensional heaving frequencies and amplitudes of the leading plate for which the stationary trailing plate contributes positively to the global thrust. The maximum global thrust efficiency, reached for an advance ratio slightly less than unity and a reduced frequency close to 5, is about the same as the maximum efficiency for an isolated plate. But for low frequencies the tandem configuration with the trailing plate at rest is more thrust efficient than the isolated plate. In the second configuration, we find that the maximum thrust efficiency is reached for a phase lag of 180o (counterstroking), particularly for an advance ratio unity and a reduced frequency 4.4, and it is practically the same as in the other configuration and that for a single plate. Supported by the Ministerio de Economía y Competitividad of Spain Grant no. DPI2013-40479-P.
de Beer, Alex G F; Samson, Jean-Sebastièn; Hua, Wei; Huang, Zishuai; Chen, Xiangke; Allen, Heather C; Roke, Sylvie
2011-12-14
We present a direct comparison of phase sensitive sum-frequency generation experiments with phase reconstruction obtained by the maximum entropy method. We show that both methods lead to the same complex spectrum. Furthermore, we discuss the strengths and weaknesses of each of these methods, analyzing possible sources of experimental and analytical errors. A simulation program for maximum entropy phase reconstruction is available at: http://lbp.epfl.ch/. © 2011 American Institute of Physics
Long-time states of inverse cascades in the presence of a maximum length scale
NASA Technical Reports Server (NTRS)
Hossain, M.; Matthaeus, W. H.; Montgomery, D.
1983-01-01
It is shown numerically, both for the two-dimensional Navier-Stokes (guiding-center plasma) equations and for two-dimensional magnetohydrodynamics, that the long-time asymptotic state in a forced inverse-cascade situation is one in which the spectrum is completely dominated by its own fundamental. The growth continues until the fundamental is dissipatively limited by its own dissipation rate.
Advances in the Development of Processing - Microstructure Relations for Titanium Alloys (Postprint)
2016-05-06
10.1002/9781119296126.ch29 14. ABSTRACT (Maximum 200 words) Advances in the fundamental understanding of microstructure evolution and plastic flow during...Abstract Advances in the fundamental understanding of microstructure evolution and plastic flow during primary and secondary processing of titanium...generation of rolling-direction secondary tension stresses. Important factors in such failures have been deduced to include the plastic properties and the
Corrected Implicit Monte Carlo
Cleveland, Mathew Allen; Wollaber, Allan Benton
2018-01-02
Here in this work we develop a set of nonlinear correction equations to enforce a consistent time-implicit emission temperature for the original semi-implicit IMC equations. We present two possible forms of correction equations: one results in a set of non-linear, zero-dimensional, non-negative, explicit correction equations, and the other results in a non-linear, non-negative, Boltzman transport correction equation. The zero-dimensional correction equations adheres to the maximum principle for the material temperature, regardless of frequency-dependence, but does not prevent maximum principle violation in the photon intensity, eventually leading to material overheating. The Boltzman transport correction guarantees adherence to the maximum principle formore » frequency-independent simulations, at the cost of evaluating a reduced source non-linear Boltzman equation. Finally, we present numerical evidence suggesting that the Boltzman transport correction, in its current form, significantly improves time step limitations but does not guarantee adherence to the maximum principle for frequency-dependent simulations.« less
Corrected implicit Monte Carlo
NASA Astrophysics Data System (ADS)
Cleveland, M. A.; Wollaber, A. B.
2018-04-01
In this work we develop a set of nonlinear correction equations to enforce a consistent time-implicit emission temperature for the original semi-implicit IMC equations. We present two possible forms of correction equations: one results in a set of non-linear, zero-dimensional, non-negative, explicit correction equations, and the other results in a non-linear, non-negative, Boltzman transport correction equation. The zero-dimensional correction equations adheres to the maximum principle for the material temperature, regardless of frequency-dependence, but does not prevent maximum principle violation in the photon intensity, eventually leading to material overheating. The Boltzman transport correction guarantees adherence to the maximum principle for frequency-independent simulations, at the cost of evaluating a reduced source non-linear Boltzman equation. We present numerical evidence suggesting that the Boltzman transport correction, in its current form, significantly improves time step limitations but does not guarantee adherence to the maximum principle for frequency-dependent simulations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cleveland, Mathew Allen; Wollaber, Allan Benton
Here in this work we develop a set of nonlinear correction equations to enforce a consistent time-implicit emission temperature for the original semi-implicit IMC equations. We present two possible forms of correction equations: one results in a set of non-linear, zero-dimensional, non-negative, explicit correction equations, and the other results in a non-linear, non-negative, Boltzman transport correction equation. The zero-dimensional correction equations adheres to the maximum principle for the material temperature, regardless of frequency-dependence, but does not prevent maximum principle violation in the photon intensity, eventually leading to material overheating. The Boltzman transport correction guarantees adherence to the maximum principle formore » frequency-independent simulations, at the cost of evaluating a reduced source non-linear Boltzman equation. Finally, we present numerical evidence suggesting that the Boltzman transport correction, in its current form, significantly improves time step limitations but does not guarantee adherence to the maximum principle for frequency-dependent simulations.« less
Zhang, Yingyun; Zhang, Yufeng; Gao, Lian; Deng, Li; Hu, Xiao; Zhang, Kexin; Li, Haiyan
2017-11-01
This study assessed the variation in the frequency locations in the Doppler ultrasound spectra for the maximum blood flow velocities of in vessels with different degrees of bilaterally axisymmetric stenosis. This was done by comparing the relationship between the velocity distributions and corresponding Doppler power spectra. First, a geometric vessel model with axisymmetric stenosis was established. This made it possible to obtain the blood flow velocity distributions for different degrees of stenosis from the solutions of the Navier-Stokes equations. Then, the Doppler spectra were calculated for the entire segment of the vessel that was covered by the sound field. Finally, the maximum frequency locations for the spectra were determined based on the intersections of the maximum values chosen from the calculated blood flow velocity distributions and their corresponding spectra. The computational analysis showed that the maximum frequencies, which corresponded to the maximum blood flow velocities for different degrees of stenosis, were located at different positions along the spectral falling edges. The location for a normal (stenosis free) vessel was in the middle of the falling edge. For vessels with increasing degrees of stenosis, this location shifted approximately linearly downward along the falling edge. For 40% stenosis, the location reached a position at the falling edge of 0.32. Results obtained using the Field II simulation tool demonstrated the validity of the theoretical analysis and calculations, and may help to improve the maximum velocity estimation accuracy for Doppler blood flow spectra in stenosed vessels. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
A new approach to harmonic elimination based on a real-time comparison method
NASA Astrophysics Data System (ADS)
Gourisetti, Sri Nikhil Gupta
Undesired harmonics are responsible for noise in a transmission channel, power loss in power electronics and in motor control. Selective Harmonic Elimination (SHE) is a well-known method used to eliminate or suppress the unwanted harmonics between the fundamental and the carrier frequency harmonic/component. But SHE bears the disadvantage of its incapability to use in real-time applications. A novel reference-carrier comparative method has been developed which can be used to generate an SPWM signal to apply in real-time systems. A modified carrier signal is designed and tested for different carrier frequencies based on the generated SPWM FFT. The carrier signal may change for different fundamental to carrier ratio that leads to solving the equations each time. An analysis to find all possible solutions for a particular carrier frequency and fundamental amplitude is performed and found. This proves that there is no one global maxima instead several local maximas exists for a particular condition set that makes this method less sensitive. Additionally, an attempt to find a universal solution that is valid for any carrier signal with predefined fundamental amplitude is performed. A uniform distribution Monte-Carlo sensitivity analysis is performed to measure the window i.e., best and worst possible solutions. The simulations are performed using MATLAB and are justified with experimental results.
High order harmonics anomaly of jet screech
NASA Astrophysics Data System (ADS)
Chen, Zhe; Wu, Jiu Hui; Ren, A.-Dan; Chen, Xin
2018-05-01
Imperfectly expanded supersonic jets under strong screech could generate both fundamental screech tones and multiple tones at the harmonics of the fundamental frequency. The paper compares the fundamental frequency of jets from both AR = 3 (Aspect Ratio) and AR = 4 rectangular nozzles, and conducts analysis of harmonics on Sound Pressure Level (SPL) spectrums of jet noise. The research suggests that the fundamental frequency of the first two- or three-order harmonics increases when the Nozzle Pressure Ratio (NPR) decreases, whereas the highest order harmonic decreases when the NPR decreases. Besides, the paper also observes the differences between the highest order harmonics and other harmonics that have never been reported before. Further analysis on flow field schlieren of AR = 3 nozzle indicates that the highest order harmonic is the outcome of interaction between second shock-cell and nonlinear instable wave. The revolution of these high order harmonics can provide guidance for the prevention of small-scale structure fatigue damage. Moreover, the distribution test of the noises is also carried out to verify the high order harmonics anomaly, and indicate that the jet noise spreads mainly towards downstream while screech towards upstream. In addition, the broadband shock-associated noise spreads vertical to the jet flow and exhibits the feature of directivity.
Koch, Peter; Bartschke, Juergen; L'huillier, Johannes A
2015-05-18
We report on the influence of self-focusing and self-defocusing in the phase-mismatched frequency doubling crystal on the third harmonic generation (THG) efficiency in a two crystal frequency tripling scheme. By detuning the temperature of the doubling crystal, the impact of a phase-mismatch in second harmonic generation (SHG) on the subsequent sum frequency mixing process was investigated. It was found that adjusting the temperature not only affected the power ratio of the second harmonic to the fundamental but also the beam diameter of the fundamental beam in the THG crystal, which was caused by self-focusing and self-defocusing of the fundamental beam, respectively. This self-action was induced by a cascaded χ(2) : χ(2) process in the phase-mismatched SHG crystal. Self-defocusing was observable for positive detuning and self-focusing for negative detuning of the phase-matching temperature. Hence, the THG efficiency was not symmetric with respect to the point of optimum phase-matching. Optimum THG was obtained for positive detuning and the resulting self-defocusing in combination with the focusing lens in front of the THG stage was also beneficial for the beam quality of the third harmonic.
225-255-GHz InP DHBT Frequency Tripler MMIC Using Complementary Split-Ring Resonator
NASA Astrophysics Data System (ADS)
Li, Xiao; Zhang, Yong; Li, Oupeng; Sun, Yan; Lu, Haiyan; Cheng, Wei; Xu, Ruimin
2017-02-01
In this paper, a novel design of frequency tripler monolithic microwave integrated circuit (MMIC) using complementary split-ring resonator (CSRR) is proposed based on 0.5-μm InP DHBT process. The CSRR-loaded microstrip structure is integrated in the tripler as a part of impedance matching network to suppress the fundamental harmonic, and another frequency tripler based on conventional band-pass filter is presented for comparison. The frequency tripler based on CSRR-loaded microstrip generates an output power between -8 and -4 dBm from 228 to 255 GHz when the input power is 6 dBm. The suppression of fundamental harmonic is better than 20 dBc at 77-82 GHz input frequency within only 0.15 × 0.15 mm2 chip area of the CSRR structure on the ground layer. Compared with the frequency tripler based on band-pass filter, the tripler using CSRR-loaded microstrip obtains a similar suppression level of unwanted harmonics and higher conversion gain within a much smaller chip area. To our best knowledge, it is the first time that CSRR is used for harmonic suppression of frequency multiplier at such high frequency band.
Instantaneous and Frequency-Warped Signal Processing Techniques for Auditory Source Separation.
NASA Astrophysics Data System (ADS)
Wang, Avery Li-Chun
This thesis summarizes several contributions to the areas of signal processing and auditory source separation. The philosophy of Frequency-Warped Signal Processing is introduced as a means for separating the AM and FM contributions to the bandwidth of a complex-valued, frequency-varying sinusoid p (n), transforming it into a signal with slowly-varying parameters. This transformation facilitates the removal of p (n) from an additive mixture while minimizing the amount of damage done to other signal components. The average winding rate of a complex-valued phasor is explored as an estimate of the instantaneous frequency. Theorems are provided showing the robustness of this measure. To implement frequency tracking, a Frequency-Locked Loop algorithm is introduced which uses the complex winding error to update its frequency estimate. The input signal is dynamically demodulated and filtered to extract the envelope. This envelope may then be remodulated to reconstruct the target partial, which may be subtracted from the original signal mixture to yield a new, quickly-adapting form of notch filtering. Enhancements to the basic tracker are made which, under certain conditions, attain the Cramer -Rao bound for the instantaneous frequency estimate. To improve tracking, the novel idea of Harmonic -Locked Loop tracking, using N harmonically constrained trackers, is introduced for tracking signals, such as voices and certain musical instruments. The estimated fundamental frequency is computed from a maximum-likelihood weighting of the N tracking estimates, making it highly robust. The result is that harmonic signals, such as voices, can be isolated from complex mixtures in the presence of other spectrally overlapping signals. Additionally, since phase information is preserved, the resynthesized harmonic signals may be removed from the original mixtures with relatively little damage to the residual signal. Finally, a new methodology is given for designing linear-phase FIR filters which require a small fraction of the computational power of conventional FIR implementations. This design strategy is based on truncated and stabilized IIR filters. These signal-processing methods have been applied to the problem of auditory source separation, resulting in voice separation from complex music that is significantly better than previous results at far lower computational cost.
Schecklmann, Martin; Vielsmeier, Veronika; Steffens, Thomas; Landgrebe, Michael; Langguth, Berthold; Kleinjung, Tobias
2012-01-01
Background Different mechanisms have been proposed to be involved in tinnitus generation, among them reduced lateral inhibition and homeostatic plasticity. On a perceptual level these different mechanisms should be reflected by the relationship between the individual audiometric slope and the perceived tinnitus pitch. Whereas some studies found the tinnitus pitch corresponding to the maximum hearing loss, others stressed the relevance of the edge frequency. This study investigates the relationship between tinnitus pitch and audiometric slope in a large sample. Methodology This retrospective observational study analyzed 286 patients. The matched tinnitus pitch was compared to the frequency of maximum hearing loss and the edge of the audiogram (steepest hearing loss) by t-tests and correlation coefficients. These analyses were performed for the whole group and for sub-groups (uni- vs. bilateral (117 vs. 338 ears), pure-tone vs. narrow-band (340 vs. 115 ears), and low and high audiometric slope (114 vs. 113 ears)). Findings For the right ear, tinnitus pitch was in the same range and correlated significantly with the frequency of maximum hearing loss, but differed from and did not correlate with the edge frequency. For the left ear, similar results were found but the correlation between tinnitus pitch and maximum hearing loss did not reach significance. Sub-group analyses (bi- and unilateral, tinnitus character, slope steepness) revealed identical results except for the sub-group with high audiometric slope which revealed a higher frequency of maximum hearing loss as compared to the tinnitus pitch. Conclusion The study-results confirm a relationship between tinnitus pitch and maximum hearing loss but not to the edge frequency, suggesting that tinnitus is rather a fill-in-phenomenon resulting from homeostatic mechanisms, than the result of deficient lateral inhibition. Sub-group analyses suggest that audiometric steepness and the side of affected ear affect this relationship. Future studies should control for these potential confounding factors. PMID:22529949
Mobinizadeh, Mohammadreza; Raeissi, Pouran; Nasiripour, Amir Ashkan; Olyaeemanesh, Alireza; Tabibi, Seyed Jamaleddin
2016-01-01
In the recent years, using health technologies to diagnose and treat diseases has had a considerable and accelerated growth. The proper use of these technologies may considerably help in the diagnosis and treatment of different diseases. On the other hand, unlimited and unrestricted entry of these technologies may result in induced demand by service providers. The aim of this study was to determine the appropriate criteria used in health technologies priority-setting models in the world. Using MESH and free text, we sought and retrieved the relevant articles from the most appropriate medical databases (the Cochrane Library, PubMed and Scopus) through three separate search strategies up to March 2015. The inclusion criteria were as follows: 1) Studies with specific criteria; 2) Articles written in English; 3) Those articles conducted in compliance with priority setting of health technologies. Data were analyzed qualitatively using a thematic synthesis technique. After screening the retrieved papers via PRISMA framework, from the 7,012 papers, 40 studies were included in the final phase. Criteria for selecting health technologies (in pre assessment and in the assessment phase) were categorized into six main themes: 1) Health outcomes; 2) Disease and target population; 3) Technology alternatives; 4) Economic aspects; 5) Evidence; 6) and other factors. "Health effects/benefits" had the maximum frequency in health outcomes (8 studies); "disease severity" had the maximum frequency in disease and target population (12 studies); "the number of alternatives" had the maximum frequency in alternatives (2 studies); "cost-effectiveness" had the maximum frequency in economic aspects (15 studies); "quality of evidence" had the maximum frequency in evidence (4 studies); and "issues concerning the health system" had the maximum frequency in other factors (10 studies). The results revealed an increase in the number of studies on health technologies priority setting around the world, and emphasized the necessity of application of a multi- criteria approach for appropriate decision making about healthcare technologies in the health systems.
Flood frequency analysis for nonstationary annual peak records in an urban drainage basin
Villarini, G.; Smith, J.A.; Serinaldi, F.; Bales, J.; Bates, P.D.; Krajewski, W.F.
2009-01-01
Flood frequency analysis in urban watersheds is complicated by nonstationarities of annual peak records associated with land use change and evolving urban stormwater infrastructure. In this study, a framework for flood frequency analysis is developed based on the Generalized Additive Models for Location, Scale and Shape parameters (GAMLSS), a tool for modeling time series under nonstationary conditions. GAMLSS is applied to annual maximum peak discharge records for Little Sugar Creek, a highly urbanized watershed which drains the urban core of Charlotte, North Carolina. It is shown that GAMLSS is able to describe the variability in the mean and variance of the annual maximum peak discharge by modeling the parameters of the selected parametric distribution as a smooth function of time via cubic splines. Flood frequency analyses for Little Sugar Creek (at a drainage area of 110 km2) show that the maximum flow with a 0.01-annual probability (corresponding to 100-year flood peak under stationary conditions) over the 83-year record has ranged from a minimum unit discharge of 2.1 m3 s- 1 km- 2 to a maximum of 5.1 m3 s- 1 km- 2. An alternative characterization can be made by examining the estimated return interval of the peak discharge that would have an annual exceedance probability of 0.01 under the assumption of stationarity (3.2 m3 s- 1 km- 2). Under nonstationary conditions, alternative definitions of return period should be adapted. Under the GAMLSS model, the return interval of an annual peak discharge of 3.2 m3 s- 1 km- 2 ranges from a maximum value of more than 5000 years in 1957 to a minimum value of almost 8 years for the present time (2007). The GAMLSS framework is also used to examine the links between population trends and flood frequency, as well as trends in annual maximum rainfall. These analyses are used to examine evolving flood frequency over future decades. ?? 2009 Elsevier Ltd.
Johnston, Keith; Tapia-Siles, Cecilia; Gerold, Bjoern; Postema, Michiel; Cochran, Sandy; Cuschieri, Alfred; Prentice, Paul
2014-12-01
Single clouds of cavitation bubbles, driven by 254kHz focused ultrasound at pressure amplitudes in the range of 0.48-1.22MPa, have been observed via high-speed shadowgraphic imaging at 1×10(6) frames per second. Clouds underwent repetitive growth, oscillation and collapse (GOC) cycles, with shock-waves emitted periodically at the instant of collapse during each cycle. The frequency of cloud collapse, and coincident shock-emission, was primarily dependent on the intensity of the focused ultrasound driving the activity. The lowest peak-to-peak pressure amplitude of 0.48MPa generated shock-waves with an average period of 7.9±0.5μs, corresponding to a frequency of f0/2, half-harmonic to the fundamental driving. Increasing the intensity gave rise to GOC cycles and shock-emission periods of 11.8±0.3, 15.8±0.3, 19.8±0.2μs, at pressure amplitudes of 0.64, 0.92 and 1.22MPa, corresponding to the higher-order subharmonics of f0/3, f0/4 and f0/5, respectively. Parallel passive acoustic detection, filtered for the fundamental driving, revealed features that correlated temporally to the shock-emissions observed via high-speed imaging, p(two-tailed) < 0.01 (r=0.996, taken over all data). Subtracting the isolated acoustic shock profiles from the raw signal collected from the detector, demonstrated the removal of subharmonic spectral peaks, in the frequency domain. The larger cavitation clouds (>200μm diameter, at maximum inflation), that developed under insonations of peak-to-peak pressure amplitudes >1.0MPa, emitted shock-waves with two or more fronts suggesting non-uniform collapse of the cloud. The observations indicate that periodic shock-emissions from acoustically driven cavitation clouds provide a source for the cavitation subharmonic signal, and that shock structure may be used to study intra-cloud dynamics at sub-microsecond timescales. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
Electroacupuncture most effectively elicits depressor and bradycardic responses at 1 Hz in humans.
Nakahara, Hidehiro; Kawada, Toru; Ueda, Shin-ya; Kawai, Eriko; Yamamoto, Hiromi; Sugimachi, Masaru; Miyamoto, Tadayoshi
2016-02-01
Acupuncture stimulation is known to act on the autonomic nervous system and elicits depressor and bradycardic effects. However, previous studies on humans did not conduct quantitative analyses on optimal acupuncture conditions such as the stimulation frequency and duration to achieve maximum depressor and bradycardic effects. The aim of the present study was to investigate the effects of varying stimulation frequencies of electroacupuncture on time-dependent changes in blood pressure and heart rate in humans. Twelve healthy volunteers participated in the study. An acupuncture needle was inserted at the Ximen acupoint (PC4 according to WHO nomenclature), located at the anterior aspect of the forearm. An electrical stimulation was delivered through the acupuncture needle at an intensity of 1 V, pulse width of 5 ms, and stimulation frequencies of 0.5, 1, 5, and 10 Hz in a random order. The duration of electroacupuncture was 6 min, during which blood pressure and heart rate responses were monitored. Group-averaged data indicated that 1-Hz electroacupuncture decreased blood pressure and heart rate. Blood pressure was significantly decreased from the prestimulation baseline value of 86.6 ± 2.9 to 81.4 ± 2.3 mmHg during 4-6 min of 1-Hz electroacupuncture (mean ± SE, P < 0.01). Heart rate was also significantly decreased (from 66.2 ± 2.0 to 62.7 ± 1.7 beats/min, P < 0.01). These results provide fundamental evidence that bradycardiac and depressor responses are effectively produced by electrical acupuncture in humans.
Sherborne Missile Fire Frequency with Unconstraint Parameters
NASA Astrophysics Data System (ADS)
Dong, Shaquan
2018-01-01
For the modeling problem of shipborne missile fire frequency, the fire frequency models with unconstant parameters were proposed, including maximum fire frequency models with unconstant parameters, and actual fire frequency models with unconstant parameters, which can be used to calculate the missile fire frequency with unconstant parameters.
NASA Technical Reports Server (NTRS)
Bahadur, H.; Parshad, R.
1981-01-01
The frequency behavior of AT-cut quartz crystals irradiated by X -, gamma rays and fast neutrons. Initial instability in frequency for gamma and neutron irradiated crystals was found. All the different radiations first give a negative frequency shift at lower doses which are followed by positive frequency shift for increased doses. Results are explained in terms of the fundamental crystal structure. Applications of the frequency results for radiation hardening are proposed.
Accurate determination of complex materials coefficients of piezoelectric resonators.
Du, Xiao-Hong; Wang, Qing-Ming; Uchino, Kenji
2003-03-01
This paper presents a method of accurately determining the complex piezoelectric and elastic coefficients of piezoelectric ceramic resonators from the measurement of the normalized electric admittance, Y, which is electric admittance Y of piezoelectric resonator normalized by the angular frequency omega. The coefficients are derived from the measurements near three special frequency points that correspond to the maximum and the minimum normalized susceptance (B) and the maximum normalized conductance (G). The complex elastic coefficient is determined from the frequencies at these points, and the real and imaginary parts of the piezoelectric coefficient are related to the derivative of the susceptance with respect to the frequency and the asymmetry of the conductance, respectively, near the maximum conductance point. The measurements for some lead zirconate titanate (PZT) based ceramics are used as examples to demonstrate the calculation and experimental procedures and the comparisons with the standard methods.
How-to-Do-It: Hands-on Activity for Mitosis, Meiosis and the Fundamentals of Heredity.
ERIC Educational Resources Information Center
Taylor, Mark F.
1988-01-01
Described is an exercise which uses inexpensive and easy-to-make materials to demonstrate the basic fundamentals of heredity. Discusses two approaches using a hypothetical insert to demonstrate inheritance, mitosis, meiosis, and genotypic and phenotypic frequencies. (CW)
A New Type of Atom Interferometry for Testing Fundamental Physics
NASA Astrophysics Data System (ADS)
Lorek, Dennis; Lämmerzahl, Claus; Wicht, Andreas
We present a new type of atom interferometer (AI) that provides a tool for ultra-high precision tests of fundamental physics. As an example we present how an AI based on highly charged hydrogen-like atoms is affected by gravitational waves (GW). A qualitative description of the quantum interferometric measurement principle is given, the modifications in the atomic Hamiltonian caused by the GW are presented, and the size of the resulting frequency shifts in hydrogen-like atoms is estimated. For a GW amplitude of h = 10-23 the frequency shift is of the order of 110μHz for an AI based on a 91-fold charged uranium ion. A frequency difference of this size can be resolved by current AIs in 1s.
Frequency-doubled vertical-external-cavity surface-emitting laser
Raymond, Thomas D.; Alford, William J.; Crawford, Mary H.; Allerman, Andrew A.
2002-01-01
A frequency-doubled semiconductor vertical-external-cavity surface-emitting laser (VECSEL) is disclosed for generating light at a wavelength in the range of 300-550 nanometers. The VECSEL includes a semiconductor multi-quantum-well active region that is electrically or optically pumped to generate lasing at a fundamental wavelength in the range of 600-1100 nanometers. An intracavity nonlinear frequency-doubling crystal then converts the fundamental lasing into a second-harmonic output beam. With optical pumping with 330 milliWatts from a semiconductor diode pump laser, about 5 milliWatts or more of blue light can be generated at 490 nm. The device has applications for high-density optical data storage and retrieval, laser printing, optical image projection, chemical-sensing, materials processing and optical metrology.
Applications of computer algebra to distributed parameter systems
NASA Technical Reports Server (NTRS)
Storch, Joel A.
1993-01-01
In the analysis of vibrations of continuous elastic systems, one often encounters complicated transcendental equations with roots directly related to the system's natural frequencies. Typically, these equations contain system parameters whose values must be specified before a numerical solution can be obtained. The present paper presents a method whereby the fundamental frequency can be obtained in analytical form to any desired degree of accuracy. The method is based upon truncation of rapidly converging series involving inverse powers of the system natural frequencies. A straightforward method to developing these series and summing them in closed form is presented. It is demonstrated how Computer Algebra can be exploited to perform the intricate analytical procedures which otherwise would render the technique difficult to apply in practice. We illustrate the method by developing two analytical approximations to the fundamental frequency of a vibrating cantilever carrying a rigid tip body. The results are compared to the numerical solution of the exact (transcendental) frequency equation over a range of system parameters.
3D conformal MRI-guided transurethral ultrasound therapy: results of gel phantom experiments
NASA Astrophysics Data System (ADS)
N'Djin, W. A.; Burtnyk, M.; McCormick, S.; Bronskill, M.; Chopra, R.
2011-09-01
MRI-guided transurethral ultrasound therapy shows promise for minimally invasive treatment of localized prostate cancer. Previous in-vivo studies demonstrated the feasibility of performing conservative treatments using real-time temperature feedback to control accurately the establishment of coagulative lesions within circumscribed prostate regions. This in-vitro study tested device configuration and control options for achieving full prostate treatments. A multi-channel MRI compatible ultrasound therapy system was evaluated in gel phantoms using 3 canine prostate models. Prostate profiles were 5 mm-step-segmented from T2-weighted MR images performed during previous in-vivo experiments. During ultrasound exposures, each ultrasound element was controlled independently by the 3D controller. Decisions on acoustic power, frequency, and device rotation rate were made in real time based on MR thermometry feedback and prostate radii. Low and high power treatment approaches using maximum acoustic powers of 10 or 20 W.cm-2 were tested as well as single and dual-frequency strategies (4.05/13.10 MHz). The dual-frequency strategy used either the fundamental frequency or the 3rd harmonic component, depending on the prostate radius. The 20 W.cm-2 dual frequency approach was the most efficient configuration in achieving full prostate treatments. Treatment times were about half the duration of those performed with 10 W.cm-2 configurations. Full prostate coagulations were performed in 16.3±6.1 min at a rate of 1.8±0.2 cm3.min-1, and resulted in very little undertreated tissue (<3%). Surrounding organs positioned beyond a safety distance of 1.4±1.0 mm from prostate boundaries were not damaged, particularly rectal wall tissues. In this study, a 3D, MR-thermometry-guided transurethral ultrasound therapy was validated in vitro in a tissue-mimicking phantom for performing full prostate treatment. A dual-frequency configuration with 20 W.cm-2 ultrasound intensity exposure showed good results with direct application to full human prostate treatments.
Magnetic nanoparticle thermometry independent of Brownian relaxation
NASA Astrophysics Data System (ADS)
Zhong, Jing; Schilling, Meinhard; Ludwig, Frank
2018-01-01
An improved method of magnetic nanoparticle (MNP) thermometry is proposed. The phase lag ϕ of the fundamental f 0 harmonic is measured to eliminate the influence of Brownian relaxation on the ratio of 3f 0 to f 0 harmonic amplitudes applying a phenomenological model, thus allowing measurements in high-frequency ac magnetic fields. The model is verified by simulations of the Fokker-Planck equation. An MNP spectrometer is calibrated for the measurements of the phase lag ϕ and the amplitudes of 3f 0 and f 0 harmonics. Calibration curves of the harmonic ratio and tanϕ are measured by varying the frequency (from 10 Hz to 1840 Hz) of ac magnetic fields with different amplitudes (from 3.60 mT to 4.00 mT) at a known temperature. A phenomenological model is employed to fit the calibration curves. Afterwards, the improved method is proposed to iteratively compensate the measured harmonic ratio with tanϕ, and consequently calculate temperature applying the static Langevin function. Experimental results on SHP-25 MNPs show that the proposed method significantly improves the systematic error to 2 K at maximum with a relative accuracy of about 0.63%. This demonstrates the feasibility of the proposed method for MNP thermometry with SHP-25 MNPs even if the MNP signal is affected by Brownian relaxation.
Cui, Xing-Yang; Shen, Qi; Yan, Mei-Chen; Zeng, Chao; Yuan, Tao; Zhang, Wen-Zhuo; Yao, Xing-Can; Peng, Cheng-Zhi; Jiang, Xiao; Chen, Yu-Ao; Pan, Jian-Wei
2018-04-15
Second-harmonic generation (SHG) is useful for obtaining single-frequency continuous-wave laser sources at various wavelengths for applications ranging from biology to fundamental physics. Using an external power-enhancement cavity is an effective approach to improve the frequency conversion efficiency. However, thermal effects limit the efficiency, particularly, in high-power operation. Therefore, reducing thermal effects is important when designing a cavity. This Letter reports the use of an external ring cavity for SHG, yielding a 5.2 W, 671 nm laser light with a conversion efficiency of 93.8±0.8% which, to the best of our knowledge, is a new record of conversion efficiency for an external ring cavity. It is achieved using a 10 mm length periodically poled potassium titanyl phosphate crystal and a 65 μm radius beam waist in the cavity so as to minimize thermal dephasing and thermal lensing. Furthermore, a method is developed to determine a conversion efficiency more accurately based on measuring the pump depletion using a photodiode detector and a maximum pump depletion up to 97% is recorded. In this method, the uncertainty is much less than that achieved in a common method by direct measuring with a power meter.
The magnetic tides of Honolulu
Love, Jeffrey J.; Rigler, Erin Joshua
2013-01-01
We review the phenomenon of time-stationary, periodic quiet-time geomagnetic tides. These are generated by the ionospheric and oceanic dynamos, and, to a lesser-extent, by the quiet-time magnetosphere, and they are affected by currents induced in the Earth's electrically conducting interior. We examine historical time series of hourly magnetic-vector measurements made at the Honolulu observatory. We construct high-resolution, frequency-domain Lomb-periodogram and maximum-entropy power spectra that reveal a panorama of stationary harmonics across periods from 0.1 to 10000.0-d, including harmonics that result from amplitude and phase modulation. We identify solar-diurnal tides and their annual and solar-cycle sideband modulations, lunar semi-diurnal tides and their solar-diurnal sidebands, and tides due to precession of lunar eccentricity and nodes. We provide evidence that a method intended for separating the ionospheric and oceanic dynamo signals by midnight subsampling of observatory data time series is prone to frequency-domain aliasing. The tidal signals we summarize in this review can be used to test our fundamental understanding of the dynamics of the quiet-time ionosphere and magnetosphere, induction in the ocean and in the electrically conducting interior of the Earth, and they are useful for defining a quiet-time baseline against which magnetospheric-storm intensity is measured.
Metabolic rate and body size are linked with perception of temporal information☆
Healy, Kevin; McNally, Luke; Ruxton, Graeme D.; Cooper, Natalie; Jackson, Andrew L.
2013-01-01
Body size and metabolic rate both fundamentally constrain how species interact with their environment, and hence ultimately affect their niche. While many mechanisms leading to these constraints have been explored, their effects on the resolution at which temporal information is perceived have been largely overlooked. The visual system acts as a gateway to the dynamic environment and the relative resolution at which organisms are able to acquire and process visual information is likely to restrict their ability to interact with events around them. As both smaller size and higher metabolic rates should facilitate rapid behavioural responses, we hypothesized that these traits would favour perception of temporal change over finer timescales. Using critical flicker fusion frequency, the lowest frequency of flashing at which a flickering light source is perceived as constant, as a measure of the maximum rate of temporal information processing in the visual system, we carried out a phylogenetic comparative analysis of a wide range of vertebrates that supported this hypothesis. Our results have implications for the evolution of signalling systems and predator–prey interactions, and, combined with the strong influence that both body mass and metabolism have on a species' ecological niche, suggest that time perception may constitute an important and overlooked dimension of niche differentiation. PMID:24109147
Lightweight structure design for supporting plate of primary mirror
NASA Astrophysics Data System (ADS)
Wang, Xiao; Wang, Wei; Liu, Bei; Qu, Yan Jun; Li, Xu Peng
2017-10-01
A topological optimization design for the lightweight technology of supporting plate of the primary mirror is presented in this paper. The supporting plate of the primary mirror is topologically optimized under the condition of determined shape, loads and environment. And the optimal structure is obtained. The diameter of the primary mirror in this paper is 450mm, and the material is SiC1 . It is better to select SiC/Al as the supporting material. Six points of axial relative displacement can be used as constraints in optimization2 . Establishing the supporting plate model and setting up the model parameters. After analyzing the force of the main mirror on the supporting plate, the model is applied with force and constraints. Modal analysis and static analysis of supporting plates are calculated. The continuum structure topological optimization mathematical model is created with the variable-density method. The maximum deformation of the surface of supporting plate under the gravity of the mirror and the first model frequency are assigned to response variable, and the entire volume of supporting structure is converted to object function. The structures before and after optimization are analyzed using the finite element method. Results show that the optimized fundamental frequency increases 29.85Hz and has a less displacement compared with the traditional structure.
Acoustic changes in student actors' voices after 12 months of training.
Walzak, Peta; McCabe, Patricia; Madill, Cate; Sheard, Christine
2008-05-01
This study was to evaluate acoustic changes in student actors' voices after 12 months of actor training. The design used was a longitudinal study. Eighteen students enrolled in an Australian tertiary 3-year acting program (nine male and nine female) were assessed at the beginning of their acting course and again 12 months later using a questionnaire, interview, maximum phonation time (MPT), reading, spontaneous speaking, sustained phonation tasks, and a pitch range task. Samples were analyzed for MPT, fundamental frequency across tasks, pitch range for speaking and reading, singing pitch range, noise-to-harmonic ratio, shimmer, and jitter. After training, measures of shimmer significantly increased for both male and female participants. Female participants' pitch range significantly increased after training, with a significantly lower mean frequency for their lowest pitch. The finding of limited or negative changes for some measures indicate that further investigation is required into the long-term effects of actor voice training and which parameters of voicing are most targeted and valued in training. Particular investigation into the relationship between training targets and outcomes could more reliably inform acting programs about changes in teaching methodologies. Further research into the relationship between specific training techniques, physiological changes, and vocal changes may also provide information on implementing more evidence-based training methods.
Navigator alignment using radar scan
Doerry, Armin W.; Marquette, Brandeis
2016-04-05
The various technologies presented herein relate to the determination of and correction of heading error of platform. Knowledge of at least one of a maximum Doppler frequency or a minimum Doppler bandwidth pertaining to a plurality of radar echoes can be utilized to facilitate correction of the heading error. Heading error can occur as a result of component drift. In an ideal situation, a boresight direction of an antenna or the front of an aircraft will have associated therewith at least one of a maximum Doppler frequency or a minimum Doppler bandwidth. As the boresight direction of the antenna strays from a direction of travel at least one of the maximum Doppler frequency or a minimum Doppler bandwidth will shift away, either left or right, from the ideal situation.
NASA Astrophysics Data System (ADS)
Thelen, Brian T.; Xique, Ismael J.; Burns, Joseph W.; Goley, G. Steven; Nolan, Adam R.; Benson, Jonathan W.
2017-04-01
With all of the new remote sensing modalities available, and with ever increasing capabilities and frequency of collection, there is a desire to fundamentally understand/quantify the information content in the collected image data relative to various exploitation goals, such as detection/classification. A fundamental approach for this is the framework of Bayesian decision theory, but a daunting challenge is to have significantly flexible and accurate multivariate models for the features and/or pixels that capture a wide assortment of distributions and dependen- cies. In addition, data can come in the form of both continuous and discrete representations, where the latter is often generated based on considerations of robustness to imaging conditions and occlusions/degradations. In this paper we propose a novel suite of "latent" models fundamentally based on multivariate Gaussian copula models that can be used for quantized data from SAR imagery. For this Latent Gaussian Copula (LGC) model, we derive an approximate, maximum-likelihood estimation algorithm and demonstrate very reasonable estimation performance even for the larger images with many pixels. However applying these LGC models to large dimen- sions/images within a Bayesian decision/classification theory is infeasible due to the computational/numerical issues in evaluating the true full likelihood, and we propose an alternative class of novel pseudo-likelihoood detection statistics that are computationally feasible. We show in a few simple examples that these statistics have the potential to provide very good and robust detection/classification performance. All of this framework is demonstrated on a simulated SLICY data set, and the results show the importance of modeling the dependencies, and of utilizing the pseudo-likelihood methods.
Quick, Christopher M; Venugopal, Arun M; Dongaonkar, Ranjeet M; Laine, Glen A; Stewart, Randolph H
2008-05-01
To return lymph to the great veins of the neck, it must be actively pumped against a pressure gradient. Mean lymph flow in a portion of a lymphatic network has been characterized by an empirical relationship (P(in) - P(out) = -P(p) + R(L)Q(L)), where P(in) - P(out) is the axial pressure gradient and Q(L) is mean lymph flow. R(L) and P(p) are empirical parameters characterizing the effective lymphatic resistance and pump pressure, respectively. The relation of these global empirical parameters to the properties of lymphangions, the segments of a lymphatic vessel bounded by valves, has been problematic. Lymphangions have a structure like blood vessels but cyclically contract like cardiac ventricles; they are characterized by a contraction frequency (f) and the slopes of the end-diastolic pressure-volume relationship [minimum value of resulting elastance (E(min))] and end-systolic pressure-volume relationship [maximum value of resulting elastance (E(max))]. Poiseuille's law provides a first-order approximation relating the pressure-flow relationship to the fundamental properties of a blood vessel. No analogous formula exists for a pumping lymphangion. We therefore derived an algebraic formula predicting lymphangion flow from fundamental physical principles and known lymphangion properties. Quantitative analysis revealed that lymph inertia and resistance to lymph flow are negligible and that lymphangions act like a series of interconnected ventricles. For a single lymphangion, P(p) = P(in) (E(max) - E(min))/E(min) and R(L) = E(max)/f. The formula was tested against a validated, realistic mathematical model of a lymphangion and found to be accurate. Predicted flows were within the range of flows measured in vitro. The present work therefore provides a general solution that makes it possible to relate fundamental lymphangion properties to lymphatic system function.
Estimation of Frequency Noise in Semiconductor Lasers Due to Mechanical Thermal Noise
NASA Technical Reports Server (NTRS)
Numata, Kenji; Camp, Jordan
2012-01-01
We evaluate mechanical thermal noise in semiconductor lasers, applying a methodology developed for fixed-spacer cavities for laser frequency stabilization. Our simple model determines an underlying fundamental limit for the frequency noise of free-running semiconductor laser, and provides a framework: where the noise may be potentially reduced with improved design.
Effect of ultrasonic cavitation on measurement of sound pressure using hydrophone
NASA Astrophysics Data System (ADS)
Thanh Nguyen, Tam; Asakura, Yoshiyuki; Okada, Nagaya; Koda, Shinobu; Yasuda, Keiji
2017-07-01
Effect of ultrasonic cavitation on sound pressure at the fundamental, second harmonic, and first ultraharmonic frequencies was investigated from low to high ultrasonic intensities. The driving frequencies were 22, 304, and 488 kHz. Sound pressure was measured using a needle-type hydrophone and ultrasonic cavitation was estimated from the broadband integrated pressure (BIP). With increasing square root of electric power applied to a transducer, the sound pressure at the fundamental frequency linearly increased initially, dropped at approximately the electric power of cavitation inception, and afterward increased again. The sound pressure at the second harmonic frequency was detected just below the electric power of cavitation inception. The first ultraharmonic component appeared at around the electric power of cavitation inception at 304 and 488 kHz. However, at 22 kHz, the first ultraharmonic component appeared at a higher electric power than that of cavitation inception.
Investigations of HID Lamp Electrodes under HF Operation
NASA Astrophysics Data System (ADS)
Reinelt, Jens; Langenscheidt, Oliver; Westermeier, Michael; Mentel, Juergen; Awakowicz, Peter
2007-10-01
Low pressure lamps are operated many years at high frequencies to improve the efficiency of these lamps and drivers. For high pressure discharge lamps this operation mode has not been installed yet. Generally it can be assumed that there are changes in the electrode physics which may lead to an undesired lamp behavior if HID lamps are operated at a high frequency. To gain insights into these fundamental changes the so called Bochum Model Lamp is used. It is an easy system which allows a fundamental research on HID electrode behavior and the near electrode region without the occurrence of acoustic resonances. For the investigation phase resolved photography, pyrometry and spectrometry is used. The presented results describe changes in the electrode temperature and changes in the kind of arc attachment on the electrodes (diffuse and spot mode) depending on frequency. Also measurements of the Electrode-Sheath-Voltage (ESV), depending on frequency, are presented.
The ACES mission: scientific objectives and present status
NASA Astrophysics Data System (ADS)
Cacciapuoti, L.; Dimarcq, N.; Salomon, C.
2017-11-01
"Atomic Clock Ensemble in Space" (ACES) is a mission in fundamental physics that will operate a new generation of atomic clocks in the microgravity environment of the International Space Station (ISS). The ACES clock signal will combine the medium term frequency stability of a space hydrogen maser (SHM) and the long term stability and accuracy of a frequency standard based on cold cesium atoms (PHARAO). Fractional frequency stability and accuracy of few parts in 1016 will be achieved. The on-board time base distributed on Earth via a microwave link (MWL) will be used to test fundamental laws of physics (Einstein's theories of Special and General Relativity, Standard Model Extension, string theories…) and to develop applications in time and frequency metrology, universal time scales, global positioning and navigation, geodesy and gravimetry. After a general overview on the mission concept and its scientific objectives, the present status of ACES instruments and sub-systems will be discussed.
Heh, Ding Yu; Tan, Eng Leong
2011-04-12
This paper presents the modeling of hemoglobin at optical frequency (250 nm - 1000 nm) using the unconditionally stable fundamental alternating-direction-implicit finite-difference time-domain (FADI-FDTD) method. An accurate model based on complex conjugate pole-residue pairs is proposed to model the complex permittivity of hemoglobin at optical frequency. Two hemoglobin concentrations at 15 g/dL and 33 g/dL are considered. The model is then incorporated into the FADI-FDTD method for solving electromagnetic problems involving interaction of light with hemoglobin. The computation of transmission and reflection coefficients of a half space hemoglobin medium using the FADI-FDTD validates the accuracy of our model and method. The specific absorption rate (SAR) distribution of human capillary at optical frequency is also shown. While maintaining accuracy, the unconditionally stable FADI-FDTD method exhibits high efficiency in modeling hemoglobin.
Heh, Ding Yu; Tan, Eng Leong
2011-01-01
This paper presents the modeling of hemoglobin at optical frequency (250 nm – 1000 nm) using the unconditionally stable fundamental alternating-direction-implicit finite-difference time-domain (FADI-FDTD) method. An accurate model based on complex conjugate pole-residue pairs is proposed to model the complex permittivity of hemoglobin at optical frequency. Two hemoglobin concentrations at 15 g/dL and 33 g/dL are considered. The model is then incorporated into the FADI-FDTD method for solving electromagnetic problems involving interaction of light with hemoglobin. The computation of transmission and reflection coefficients of a half space hemoglobin medium using the FADI-FDTD validates the accuracy of our model and method. The specific absorption rate (SAR) distribution of human capillary at optical frequency is also shown. While maintaining accuracy, the unconditionally stable FADI-FDTD method exhibits high efficiency in modeling hemoglobin. PMID:21559129
NASA Astrophysics Data System (ADS)
Klimchitskaya, G. L.; Mostepanenko, V. M.
2018-06-01
The analytic expressions for the maximum and minimum reflectances of optical films coated with gapped graphene are derived in the application region of the Dirac model taking into account multiple reflections. The respective film thicknesses are also found. In so doing the film material is described by the frequency-dependent index of refraction and graphene by the polarization tensor defined along the real frequency axis. The developed formalism is illustrated by an example of the graphene-coated film made of amorphous silica. Numerical computations of the maximum and minimum reflectances and respective film thicknesses are performed at room temperature in two frequency regions belonging to the near-infrared and far-infrared domains. It is shown that in the far-infrared domain the graphene coating has a profound effect on the values of maximum reflectance and respective film thickness leading to a relative increase in their values by up to 65% and 50%, respectively. The maximum transmittance of a graphene-coated film of appropriately chosen thickness is shown to exceed 90%. Possible applications of the obtained results are discussed.
Tromberg, B.J.; Tsay, T.T.; Berns, M.W.; Svaasand, L.O.; Haskell, R.C.
1995-06-13
Optical measurements of turbid media, that is media characterized by multiple light scattering, is provided through an apparatus and method for exposing a sample to a modulated laser beam. The light beam is modulated at a fundamental frequency and at a plurality of integer harmonics thereof. Modulated light is returned from the sample and preferentially detected at cross frequencies at frequencies slightly higher than the fundamental frequency and at integer harmonics of the same. The received radiance at the beat or cross frequencies is compared against a reference signal to provide a measure of the phase lag of the radiance and modulation ratio relative to a reference beam. The phase and modulation amplitude are then provided as a frequency spectrum by an array processor to which a computer applies a complete curve fit in the case of highly scattering samples or a linear curve fit below a predetermined frequency in the case of highly absorptive samples. The curve fit in any case is determined by the absorption and scattering coefficients together with a concentration of the active substance in the sample. Therefore, the curve fitting to the frequency spectrum can be used both for qualitative and quantitative analysis of substances in the sample even though the sample is highly turbid. 14 figs.
Tromberg, Bruce J.; Tsay, Tsong T.; Berns, Michael W.; Svaasand, Lara O.; Haskell, Richard C.
1995-01-01
Optical measurements of turbid media, that is media characterized by multiple light scattering, is provided through an apparatus and method for exposing a sample to a modulated laser beam. The light beam is modulated at a fundamental frequency and at a plurality of integer harmonics thereof. Modulated light is returned from the sample and preferentially detected at cross frequencies at frequencies slightly higher than the fundamental frequency and at integer harmonics of the same. The received radiance at the beat or cross frequencies is compared against a reference signal to provide a measure of the phase lag of the radiance and modulation ratio relative to a reference beam. The phase and modulation amplitude are then provided as a frequency spectrum by an array processor to which a computer applies a complete curve fit in the case of highly scattering samples or a linear curve fit below a predetermined frequency in the case of highly absorptive samples. The curve fit in any case is determined by the absorption and scattering coefficients together with a concentration of the active substance in the sample. Therefore, the curve fitting to the frequency spectrum can be used both for qualitative and quantitative analysis of substances in the sample even though the sample is highly turbid.
Multiscale energy reallocation during low-frequency steady-state brain response.
Wang, Yifeng; Chen, Wang; Ye, Liangkai; Biswal, Bharat B; Yang, Xuezhi; Zou, Qijun; Yang, Pu; Yang, Qi; Wang, Xinqi; Cui, Qian; Duan, Xujun; Liao, Wei; Chen, Huafu
2018-05-01
Traditional task-evoked brain activations are based on detection and estimation of signal change from the mean signal. By contrast, the low-frequency steady-state brain response (lfSSBR) reflects frequency-tagging activity at the fundamental frequency of the task presentation and its harmonics. Compared to the activity at these resonant frequencies, brain responses at nonresonant frequencies are largely unknown. Additionally, because the lfSSBR is defined by power change, we hypothesize using Parseval's theorem that the power change reflects brain signal variability rather than the change of mean signal. Using a face recognition task, we observed power increase at the fundamental frequency (0.05 Hz) and two harmonics (0.1 and 0.15 Hz) and power decrease within the infra-slow frequency band (<0.1 Hz), suggesting a multifrequency energy reallocation. The consistency of power and variability was demonstrated by the high correlation (r > .955) of their spatial distribution and brain-behavior relationship at all frequency bands. Additionally, the reallocation of finite energy was observed across various brain regions and frequency bands, forming a particular spatiotemporal pattern. Overall, results from this study strongly suggest that frequency-specific power and variability may measure the same underlying brain activity and that these results may shed light on different mechanisms between lfSSBR and brain activation, and spatiotemporal characteristics of energy reallocation induced by cognitive tasks. © 2018 Wiley Periodicals, Inc.
System frequency support of permanent magnet synchronous generator-based wind power plant
NASA Astrophysics Data System (ADS)
Wu, Ziping
With ever-increasing penetration of wind power into modern electric grids all over the world, a trending replacement of conventional synchronous generators by large wind power plants will likely result in the poor overall frequency regulation performance. On the other hand, permanent magnet synchronous generator wind Turbine System (PMSG-WTG) with full power back to back converters tends to become one of the most promising wind turbine technologies thanks to various advantages. It possesses a significant amount of kinetic energy stored in the rotating mass of turbine blades, which can be utilized to enhance the total inertia of power system. Additionally, the deloaded operation and decoupled control of active and reactive power make it possible for PMSG-WTG to provide a fast frequency regulation through full-power converter. First of all, a comprehensive and in-depth survey is conducted to analyze the motivations for incorporating the inertial response and frequency regulation of VSWT into the system frequency regulation. Besides, control classifications, fundamental control concepts and advanced control schemes implemented for auxiliary frequency support of individual WT or wind power plant are elaborated along with a comparison of the potential frequency regulation capabilities of four major types of WTs. Secondly, a Controls Advanced Research Turbine2-Permanent Magnet Synchronous Generator wind turbine (CART2-PMSG) integrated model representing the typical configuration and operation characteristics of PMSG-WT is established in Matlab/Simulink,. Meanwhile, two different rotor-side converter control schemes, including rotor speed-based control and active power-based control, are integrated into this CART2-PMSG integrated model to perform Maximum Power Point Tracking (MPPT) operation over a wide range of wind speeds, respectively. Thirdly, a novel comprehensive frequency regulation (CFR) control scheme is developed and implemented into the CART2-PMSG model based on rotor speed control. The proposed control scheme is achieved through the coordinated control between rotor speed and modified pitch angle in accordance with different specified wind speed modes. Fourth, an improved inertial control method based on the maximum power point tracking operation curve is introduced to boost the overall frequency support capability of PMSG-WTGs based on rotor speed control. Fifth, a novel control method based on the torque limit (TLC) is proposed for the purpose of maximizing the wind turbine (WT)'s inertial response. To avoid the SFD caused by the deloaded operation of WT, a small-scale battery energy storage system (BESS) model is established and implemented to eliminate this impact and meanwhile assist the restoration of wind turbine to MPPT mode by means of coordinated control strategy between BESS and PMSG-WTG. Last but not the least, all three types of control strategies are implemented in the CART2-PMSG integrated model based on rotor speed control or active power control respectively to evaluate their impacts on the wind turbine's structural loads during the frequency regulation process. Simulation results demonstrate that all the proposed methods can enhance the overall frequency regulation performance while imposing very slight negative impact on the major mechanical components of the wind turbine.
NASA Astrophysics Data System (ADS)
Panagoulia, Dionysia; Vlahogianni, Eleni I.
2018-06-01
A methodological framework based on nonlinear recurrence analysis is proposed to examine the historical data evolution of extremes of maximum and minimum daily mean areal temperature patterns over time under different climate scenarios. The methodology is based on both historical data and atmospheric General Circulation Model (GCM) produced climate scenarios for the periods 1961-2000 and 2061-2100 which correspond to 1 × CO2 and 2 × CO2 scenarios. Historical data were derived from the actual daily observations coupled with atmospheric circulation patterns (CPs). The dynamics of the temperature was reconstructed in the phase-space from the time series of temperatures. The statistically comparing different temperature patterns were based on some discriminating statistics obtained by the Recurrence Quantification Analysis (RQA). Moreover, the bootstrap method of Schinkel et al. (2009) was adopted to calculate the confidence bounds of RQA parameters based on a structural preserving resampling. The overall methodology was implemented to the mountainous Mesochora catchment in Central-Western Greece. The results reveal substantial similarities between the historical maximum and minimum daily mean areal temperature statistical patterns and their confidence bounds, as well as the maximum and minimum temperature patterns in evolution under the 2 × CO2 scenario. A significant variability and non-stationary behaviour characterizes all climate series analyzed. Fundamental differences are produced from the historical and maximum 1 × CO2 scenarios, the maximum 1 × CO2 and minimum 1 × CO2 scenarios, as well as the confidence bounds for the two CO2 scenarios. The 2 × CO2 scenario reflects the strongest shifts in intensity, duration and frequency in temperature patterns. Such transitions can help the scientists and policy makers to understand the effects of extreme temperature changes on water resources, economic development, and health of ecosystems and hence to proceed to effective proactive management of extreme phenomena. The impacts of the findings on the predictability of the extreme daily mean areal temperature patterns are also commented.
Pneumatic oscillator circuits for timing and control of integrated microfluidics.
Duncan, Philip N; Nguyen, Transon V; Hui, Elliot E
2013-11-05
Frequency references are fundamental to most digital systems, providing the basis for process synchronization, timing of outputs, and waveform synthesis. Recently, there has been growing interest in digital logic systems that are constructed out of microfluidics rather than electronics, as a possible means toward fully integrated laboratory-on-a-chip systems that do not require any external control apparatus. However, the full realization of this goal has not been possible due to the lack of on-chip frequency references, thus requiring timing signals to be provided from off-chip. Although microfluidic oscillators have been demonstrated, there have been no reported efforts to characterize, model, or optimize timing accuracy, which is the fundamental metric of a clock. Here, we report pneumatic ring oscillator circuits built from microfluidic valves and channels. Further, we present a compressible-flow analysis that differs fundamentally from conventional circuit theory, and we show the utility of this physically based model for the optimization of oscillator stability. Finally, we leverage microfluidic clocks to demonstrate circuits for the generation of phase-shifted waveforms, self-driving peristaltic pumps, and frequency division. Thus, pneumatic oscillators can serve as on-chip frequency references for microfluidic digital logic circuits. On-chip clocks and pumps both constitute critical building blocks on the path toward achieving autonomous laboratory-on-a-chip devices.
Stimulus presentation order and the perception of lexical tones in Cantonese
NASA Astrophysics Data System (ADS)
Francis, Alexander L.; Ciocca, Valter
2003-09-01
Listeners' auditory discrimination of vowel sounds depends in part on the order in which stimuli are presented. Such presentation order effects have been argued to be language independent, and to result from psychophysical (not speech- or language-specific) factors such as the decay of memory traces over time or increased weighting of later-occurring stimuli. In the present study, native Cantonese speakers' discrimination of a linguistic tone continuum is shown to exhibit order of presentation effects similar to those shown for vowels in previous studies. When presented with two successive syllables differing in fundamental frequency by approximately 4 Hz, listeners were significantly more sensitive to this difference when the first syllable was higher in frequency than the second. However, American English-speaking listeners with no experience listening to Cantonese showed no such contrast effect when tested in the same manner using the same stimuli. Neither English nor Cantonese listeners showed any order of presentation effects in the discrimination of a nonspeech continuum in which tokens had the same fundamental frequencies as the Cantonese speech tokens but had a qualitatively non-speech-like timbre. These results suggest that tone presentation order effects, unlike vowel effects, may be language specific, possibly resulting from the need to compensate for utterance-related pitch declination when evaluating fundamental frequency for tone identification.
The acoustic structure of male giant panda bleats varies according to intersexual context.
Charlton, Benjamin D; Keating, Jennifer L; Rengui, Li; Huang, Yan; Swaisgood, Ronald R
2015-09-01
Although the acoustic structure of mammal vocal signals often varies according to the social context of emission, relatively few mammal studies have examined acoustic variation during intersexual advertisement. In the current study male giant panda bleats were recorded during the breeding season in three behavioural contexts: vocalising alone, during vocal interactions with females outside of peak oestrus, and during vocal interactions with peak-oestrous females. Male bleats produced during vocal interactions with peak-oestrous females were longer in duration and had higher mean fundamental frequency than those produced when males were either involved in a vocal interaction with a female outside of peak oestrus or vocalising alone. In addition, males produced bleats with higher rates of fundamental frequency modulation when they were vocalising alone than when they were interacting with females. These results show that acoustic features of male giant panda bleats have the potential to signal the caller's motivational state, and suggest that males increase the rate of fundamental frequency modulation in bleats when they are alone to maximally broadcast their quality and promote close-range contact with receptive females during the breeding season.
NASA Astrophysics Data System (ADS)
Xie, Zhengyang; Zheng, Xiaoping; Li, Shangyuan; Yan, Haozhe; Xiao, Xuedi; Xue, Xiaoxiao
2018-06-01
We propose an injection-locked optoelectronic oscillator (OEO) based wide-band frequency doubler, which is free from phase noise deterioration in electrical doubler, by using a dual-parallel Mach-Zehnder modulator (DPMZM). Through adjusting the optical phase shifts in different arms of the DPMZM, the doubling signal oscillates in the OEO loop while the fundamental signal takes on phase modulation over the light and vanishes at photo-detector (PD) output. By controlling power of fundamental signal the restriction of phase-noise deterioration rule in electrical doubler is totally canceled. Experimental results show that the doubler output has a better phase noise value of, for example, -117 dBc/Hz @ 10 kHz at 6 GHz with an improvement more than 17 dB and 23 dB compared with that of fundamental input and electrical doubler, respectively. Besides, the stability of this doubler output can reach to 1 . 5 × 10-14 at 1000 s averaging time. The frequency range of doubling signal is limited by the bandwidth of electrical amplifier in OEO loop.
Suspension-thermal noise in spring–antispring systems for future gravitational-wave detectors
NASA Astrophysics Data System (ADS)
Harms, Jan; Mow-Lowry, Conor M.
2018-01-01
Spring–antispring systems have been investigated in the context of low-frequency seismic isolation in high-precision optical experiments. These systems provide the possibility to tune the fundamental resonance frequency to, in principle, arbitrarily low values, and at the same time maintain a compact design. It was argued though that thermal noise in spring–antispring systems would not be as small as one may naively expect from lowering the fundamental resonance frequency. In this paper, we present calculations of suspension-thermal noise for spring–antispring systems potentially relevant in future gravitational-wave detectors, i.e. the beam-balance tiltmeter, and the Roberts linkage. We find a concise expression of the suspension-thermal noise spectrum, which assumes a form very similar to the well-known expression for a simple pendulum. For systems such as the Roberts linkage foreseen as passive seismic isolation, we find that while they can provide strong seismic isolation due to a very low fundamental resonance frequency, their thermal noise is determined by the dimension of the system and is insensitive to fine-tunings of the geometry that can strongly influence the resonance frequency. By analogy, i.e. formal similarity of the equations of motion, this is true for all horizontal mechanical isolation systems with spring–antispring dynamics. This imposes strict requirements on mechanical spring–antispring systems for seismic isolation in potential future low-frequency gravitational-wave detectors as we discuss for the four main concepts, atom-interferometric, superconducting, torsion-bars, and conventional laser interferometer, and generally suggests that thermal noise needs to be evaluated carefully for high-precision experiments implementing spring–antispring dynamics.
Base units of the SI, fundamental constants and modern quantum physics.
Bordé, Christian J
2005-09-15
Over the past 40 years, a number of discoveries in quantum physics have completely transformed our vision of fundamental metrology. This revolution starts with the frequency stabilization of lasers using saturation spectroscopy and the redefinition of the metre by fixing the velocity of light c. Today, the trend is to redefine all SI base units from fundamental constants and we discuss strategies to achieve this goal. We first consider a kinematical frame, in which fundamental constants with a dimension, such as the speed of light c, the Planck constant h, the Boltzmann constant k(B) or the electron mass m(e) can be used to connect and redefine base units. The various interaction forces of nature are then introduced in a dynamical frame, where they are completely characterized by dimensionless coupling constants such as the fine structure constant alpha or its gravitational analogue alpha(G). This point is discussed by rewriting the Maxwell and Dirac equations with new force fields and these coupling constants. We describe and stress the importance of various quantum effects leading to the advent of this new quantum metrology. In the second part of the paper, we present the status of the seven base units and the prospects of their possible redefinitions from fundamental constants in an experimental perspective. The two parts can be read independently and they point to these same conclusions concerning the redefinitions of base units. The concept of rest mass is directly related to the Compton frequency of a body, which is precisely what is measured by the watt balance. The conversion factor between mass and frequency is the Planck constant, which could therefore be fixed in a realistic and consistent new definition of the kilogram based on its Compton frequency. We discuss also how the Boltzmann constant could be better determined and fixed to replace the present definition of the kelvin.
NASA Astrophysics Data System (ADS)
Tian, Hongbo
As the candidate target container material of the new Spallation Neutron Source (SNS) being designed and constructed at the Oak Ridge National Laboratory (ORNL), Type 316 low-carbon nitrogen-added (LN) stainless steel (SS) will operate in an aggressive environment, subjected to intense fluxes of high-energy protons and neutrons while exposed to liquid mercury. The current project is oriented toward materials studies regarding the effects of test environment and frequency on the fatigue behavior of 316 LN SS. In order to study the structural applications of this material and improve the fundamental understanding of the fatigue damage mechanisms, fatigue tests were performed in air and mercury environments at various frequencies and R ratios (R = sigma min/sigmamax, sigmamin and sigmamax are the applied minimum and maximum stresses, respectively). Fatigue data were developed for the structural design and engineering applications of this material. Specifically, high-cycle fatigue tests, fatigue crack-propagation tests, and ultrahigh cycle fatigue tests up to 10 9 cycles were conducted in air and mercury with test frequencies from 10 Hz to 700 Hz. Microstructure characterizations were performed using optical microscopy (OM), scanning-electron microscopy (SEM), and transmission-electron microscopy (TEM). It was found that mercury doesn't seem to have a large impact on the crack-initiation behavior of 316 LN SS. However, the crack-propagation mechanisms in air and mercury are different in some test conditions. Transgranular cracks seem to be the main mechanism in air, and intergranular in mercury. A significant specimen self-heating effect was found during high-cycle faituge. Theoretical calculation was performed to predict temperature responses of the material subjected to cyclic deformation. The predicted cyclic temperature evolution seems to be in good agreement with the experimental results.
Auffhammer, Maximilian; Baylis, Patrick; Hausman, Catherine H.
2017-01-01
It has been suggested that climate change impacts on the electric sector will account for the majority of global economic damages by the end of the current century and beyond [Rose S, et al. (2014) Understanding the Social Cost of Carbon: A Technical Assessment]. The empirical literature has shown significant increases in climate-driven impacts on overall consumption, yet has not focused on the cost implications of the increased intensity and frequency of extreme events driving peak demand, which is the highest load observed in a period. We use comprehensive, high-frequency data at the level of load balancing authorities to parameterize the relationship between average or peak electricity demand and temperature for a major economy. Using statistical models, we analyze multiyear data from 166 load balancing authorities in the United States. We couple the estimated temperature response functions for total daily consumption and daily peak load with 18 downscaled global climate models (GCMs) to simulate climate change-driven impacts on both outcomes. We show moderate and heterogeneous changes in consumption, with an average increase of 2.8% by end of century. The results of our peak load simulations, however, suggest significant increases in the intensity and frequency of peak events throughout the United States, assuming today’s technology and electricity market fundamentals. As the electricity grid is built to endure maximum load, our findings have significant implications for the construction of costly peak generating capacity, suggesting additional peak capacity costs of up to 180 billion dollars by the end of the century under business-as-usual. PMID:28167756
Adaptive Gain-based Stable Power Smoothing of a DFIG
Muljadi, Eduard; Lee, Hyewon; Hwang, Min; ...
2017-11-01
In a power system that has a high wind penetration, the output power fluctuation of a large-scale wind turbine generator (WTG) caused by the varying wind speed increases the maximum frequency deviation, which is an important metric to assess the quality of electricity, because of the reduced system inertia. This paper proposes a stable power-smoothing scheme of a doubly-fed induction generator (DFIG) that can suppress the maximum frequency deviation, particularly for a power system with a high wind penetration. To do this, the proposed scheme employs an additional control loop relying on the system frequency deviation that operates in combinationmore » with the maximum power point tracking control loop. To improve the power-smoothing capability while guaranteeing the stable operation of a DFIG, the gain of the additional loop is modified with the rotor speed and frequency deviation. The gain is set to be high if the rotor speed and/or frequency deviation is large. Here, the simulation results based on the IEEE 14-bus system demonstrate that the proposed scheme significantly lessens the output power fluctuation of a WTG under various scenarios by modifying the gain with the rotor speed and frequency deviation, and thereby it can regulate the frequency deviation within a narrow range.« less
Adaptive Gain-based Stable Power Smoothing of a DFIG
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muljadi, Eduard; Lee, Hyewon; Hwang, Min
In a power system that has a high wind penetration, the output power fluctuation of a large-scale wind turbine generator (WTG) caused by the varying wind speed increases the maximum frequency deviation, which is an important metric to assess the quality of electricity, because of the reduced system inertia. This paper proposes a stable power-smoothing scheme of a doubly-fed induction generator (DFIG) that can suppress the maximum frequency deviation, particularly for a power system with a high wind penetration. To do this, the proposed scheme employs an additional control loop relying on the system frequency deviation that operates in combinationmore » with the maximum power point tracking control loop. To improve the power-smoothing capability while guaranteeing the stable operation of a DFIG, the gain of the additional loop is modified with the rotor speed and frequency deviation. The gain is set to be high if the rotor speed and/or frequency deviation is large. Here, the simulation results based on the IEEE 14-bus system demonstrate that the proposed scheme significantly lessens the output power fluctuation of a WTG under various scenarios by modifying the gain with the rotor speed and frequency deviation, and thereby it can regulate the frequency deviation within a narrow range.« less
ERIC Educational Resources Information Center
Clarke, John
1970-01-01
Discusses the theory of the Josephson Effect, the derivation of the Josephson voltage-frequency relation, and methods of measuring the fundamental constatn ratio e/h. Various types of Josephson junctions are described. The impact of the measurement of e/h upin the fundamental constants and quantum electro-dynamics is briefly discussed.…
NASA Astrophysics Data System (ADS)
Zhang, Jingdong; Zhu, Tao; Zheng, Hua; Kuang, Yang; Liu, Min; Huang, Wei
2017-04-01
The round trip time of the light pulse limits the maximum detectable frequency response range of vibration in phase-sensitive optical time domain reflectometry (φ-OTDR). We propose a method to break the frequency response range restriction of φ-OTDR system by modulating the light pulse interval randomly which enables a random sampling for every vibration point in a long sensing fiber. This sub-Nyquist randomized sampling method is suits for detecting sparse-wideband- frequency vibration signals. Up to MHz resonance vibration signal with over dozens of frequency components and 1.153MHz single frequency vibration signal are clearly identified for a sensing range of 9.6km with 10kHz maximum sampling rate.
Dynamic modelling and experimental study of asymmetric optothermal microactuator
NASA Astrophysics Data System (ADS)
Wang, Shuying; Chun, Qin; You, Qingyang; Wang, Yingda; Zhang, Haijun
2017-01-01
This paper reports the dynamic modelling and experimental study of an asymmetric optothermal microactuator (OTMA). According to the principle of thermal flux, a theoretical model for instantaneous temperature distribution of an expansion arm is established and the expression of expansion increment is derived. Dynamic expansion properties of the arm under laser pulse irradiation are theoretically analyzed indicating that both of the maximum expansion and expansion amplitude decrease with the pulse frequency increasing. Experiments have been further carried out on an OTMA fabricated by using an excimer laser micromachining system. It is shown that the OTMA deflects periodically with the same frequency of laser pulse irradiation. Experimental results also prove that both OTMA's maximum deflection and deflection amplitude (related to maximum expansion and expansion amplitude of the arm) decrease as frequency increases, matching with the theoretical model quite well. Even though the OTMA's deflection decrease at higher frequency, it is still capable of generating 8.2 μm maximum deflection and 4.2 μm deflection amplitude under 17 Hz/2 mW laser pulse irradiation. This work improves the potential applications of optothermal microactuators in micro-opto-electro-mechanical system (MOEMS) and micro/nano-technology fields.
NASA Astrophysics Data System (ADS)
Boschi, Lapo
2006-10-01
I invert a large set of teleseismic phase-anomaly observations, to derive tomographic maps of fundamental-mode surface wave phase velocity, first via ray theory, then accounting for finite-frequency effects through scattering theory, in the far-field approximation and neglecting mode coupling. I make use of a multiple-resolution pixel parametrization which, in the assumption of sufficient data coverage, should be adequate to represent strongly oscillatory Fréchet kernels. The parametrization is finer over North America, a region particularly well covered by the data. For each surface-wave mode where phase-anomaly observations are available, I derive a wide spectrum of plausible, differently damped solutions; I then conduct a trade-off analysis, and select as optimal solution model the one associated with the point of maximum curvature on the trade-off curve. I repeat this exercise in both theoretical frameworks, to find that selected scattering and ray theoretical phase-velocity maps are coincident in pattern, and differ only slightly in amplitude.
NASA Astrophysics Data System (ADS)
Guenanou, A.; Houmat, A.
2018-05-01
The optimum stacking sequence design for the maximum fundamental frequency of symmetrically laminated composite circular plates with curvilinear fibres is investigated for the first time using a layer-wise optimization method. The design variables are two fibre orientation angles per layer. The fibre paths are constructed using the method of shifted paths. The first-order shear deformation plate theory and a curved square p-element are used to calculate the objective function. The blending function method is used to model accurately the geometry of the circular plate. The equations of motion are derived using Lagrange's method. The numerical results are validated by means of a convergence test and comparison with published values for symmetrically laminated composite circular plates with rectilinear fibres. The material parameters, boundary conditions, number of layers and thickness are shown to influence the optimum solutions to different extents. The results should serve as a benchmark for optimum stacking sequences of symmetrically laminated composite circular plates with curvilinear fibres.
Foreshock sequences and short-term earthquake predictability on East Pacific Rise transform faults.
McGuire, Jeffrey J; Boettcher, Margaret S; Jordan, Thomas H
2005-03-24
East Pacific Rise transform faults are characterized by high slip rates (more than ten centimetres a year), predominantly aseismic slip and maximum earthquake magnitudes of about 6.5. Using recordings from a hydroacoustic array deployed by the National Oceanic and Atmospheric Administration, we show here that East Pacific Rise transform faults also have a low number of aftershocks and high foreshock rates compared to continental strike-slip faults. The high ratio of foreshocks to aftershocks implies that such transform-fault seismicity cannot be explained by seismic triggering models in which there is no fundamental distinction between foreshocks, mainshocks and aftershocks. The foreshock sequences on East Pacific Rise transform faults can be used to predict (retrospectively) earthquakes of magnitude 5.4 or greater, in narrow spatial and temporal windows and with a high probability gain. The predictability of such transform earthquakes is consistent with a model in which slow slip transients trigger earthquakes, enrich their low-frequency radiation and accommodate much of the aseismic plate motion.
Isolating contour information from arbitrary images
NASA Technical Reports Server (NTRS)
Jobson, Daniel J.
1989-01-01
Aspects of natural vision (physiological and perceptual) serve as a basis for attempting the development of a general processing scheme for contour extraction. Contour information is assumed to be central to visual recognition skills. While the scheme must be regarded as highly preliminary, initial results do compare favorably with the visual perception of structure. The scheme pays special attention to the construction of a smallest scale circular difference-of-Gaussian (DOG) convolution, calibration of multiscale edge detection thresholds with the visual perception of grayscale boundaries, and contour/texture discrimination methods derived from fundamental assumptions of connectivity and the characteristics of printed text. Contour information is required to fall between a minimum connectivity limit and maximum regional spatial density limit at each scale. Results support the idea that contour information, in images possessing good image quality, is (centered at about 10 cyc/deg and 30 cyc/deg). Further, lower spatial frequency channels appear to play a major role only in contour extraction from images with serious global image defects.
NASA Astrophysics Data System (ADS)
Tün, M.; Pekkan, E.; Özel, O.; Guney, Y.
2016-10-01
Amplification can occur in a graben as a result of strong earthquake-induced ground motion. Thus, in seismic hazard and seismic site response studies, it is of the utmost importance to determine the geometry of the bedrock depth. The main objectives of this study were to determine the bedrock depth and map the depth-to-bedrock ratio for use in land use planning in regard to the mitigation of earthquake hazards in the Eskişehir Basin. The fundamental resonance frequencies (fr) of 318 investigation sites in the Eskişehir Basin were determined through case studies, and the 2-D S-wave velocity structure down to the bedrock depth was explored. Single-station microtremor data were collected from the 318 sites, as well as microtremor array data from nine sites, seismic reflection data from six sites, deep-drilling log data from three sites and shallow drilling log data from ten sites in the Eskişehir Graben. The fundamental resonance frequencies of the Eskişehir Basin sites were obtained from the microtremor data using the horizontal-to vertical (H/V) spectral ratio (HVSR) method. The phase velocities of the Rayleigh waves were estimated from the microtremor data using the spatial autocorrelation (SPAC) method. The fundamental resonance frequency range at the deepest point of the Eskişehir Basin was found to be 0.23-0.35 Hz. Based on the microtremor array measurements and the 2-D S-wave velocity profiles obtained using the SPAC method, a bedrock level with an average velocity of 1300 m s-1 was accepted as the bedrock depth limit in the region. The log data from a deep borehole and a seismic reflection cross-section of the basement rocks of the Eskişehir Basin were obtained and permitted a comparison of bedrock levels. Tests carried out using a multichannel walk-away technique permitted a seismic reflection cross-section to be obtained up to a depth of 1500-2000 m using an explosive energy source. The relationship between the fundamental resonance frequency in the Eskişehir Basin and the results of deep drilling, shallow drilling, shear wave velocity measurement and sedimentary cover depth measurement obtained from the seismic reflection section was expressed in the form of a nonlinear regression equation. An empirical relationship between fr, the thickness of sediments and the bedrock depth is suggested for use in future microzonation studies of sites in the region. The results revealed a maximum basin depth of 1000 m, located in the northeast of the Eskişehir Basin, and the SPAC and HVSR results indicated that within the study area the basin is characterized by a thin local sedimentary cover with low shear wave velocity overlying stiff materials, resulting in a sharp velocity contrast. The thicknesses of the old Quaternary and Tertiary fluvial sediments within the basin serve as the primary data sources in seismic hazard and seismic site response studies, and these results add to the body of available seismic hazard data contributing to a seismic microzonation of the Eskişehir Graben in advance of the severe earthquakes expected in the Anatolian Region.
Intrinsic fundamental frequency of vowels is moderated by regional dialect
Jacewicz, Ewa; Fox, Robert Allen
2015-01-01
There has been a long-standing debate whether the intrinsic fundamental frequency (IF0) of vowels is an automatic consequence of articulation or whether it is independently controlled by speakers to perceptually enhance vowel contrasts along the height dimension. This paper provides evidence from regional variation in American English that IF0 difference between high and low vowels is, in part, controlled and varies across dialects. The sources of this F0 control are socio-cultural and cannot be attributed to differences in the vowel inventory size. The socially motivated enhancement was found only in prosodically prominent contexts. PMID:26520352
Ma, Jianguo; Martin, K. Heath; Dayton, Paul A.; Jiang, Xiaoning
2014-01-01
Current intravascular ultrasound (IVUS) probes are not optimized for contrast detection because of their design for high-frequency fundamental-mode imaging. However, data from transcutaneous contrast imaging suggests the possibility of utilizing contrast ultrasound for molecular imaging or vasa vasorum assessment to further elucidate atherosclerotic plaque deposition. This paper presents the design, fabrication, and characterization of a small-aperture (0.6 × 3 mm) IVUS probe optimized for high-frequency contrast imaging. The design utilizes a dual-frequency (6.5 MHz/30 MHz) transducer arrangement for exciting microbubbles at low frequencies (near their resonance) and detecting their broadband harmonics at high frequencies, minimizing detected tissue backscatter. The prototype probe is able to generate nonlinear microbubble response with more than 1.2 MPa of rarefractional pressure (mechanical index: 0.48) at 6.5 MHz, and is also able to detect microbubble response with a broadband receiving element (center frequency: 30 MHz, −6-dB fractional bandwidth: 58.6%). Nonlinear super-harmonics from microbubbles flowing through a 200-μm-diameter micro-tube were clearly detected with a signal-to-noise ratio higher than 12 dB. Preliminary phantom imaging at the fundamental frequency (30 MHz) and dual-frequency super-harmonic imaging results suggest the promise of small aperture, dual-frequency IVUS transducers for contrast-enhanced IVUS imaging. PMID:24801226
Auditory perception bias in speech imitation
Postma-Nilsenová, Marie; Postma, Eric
2013-01-01
In an experimental study, we explored the role of auditory perception bias in vocal pitch imitation. Psychoacoustic tasks involving a missing fundamental indicate that some listeners are attuned to the relationship between all the higher harmonics present in the signal, which supports their perception of the fundamental frequency (the primary acoustic correlate of pitch). Other listeners focus on the lowest harmonic constituents of the complex sound signal which may hamper the perception of the fundamental. These two listener types are referred to as fundamental and spectral listeners, respectively. We hypothesized that the individual differences in speakers' capacity to imitate F0 found in earlier studies, may at least partly be due to the capacity to extract information about F0 from the speech signal. Participants' auditory perception bias was determined with a standard missing fundamental perceptual test. Subsequently, speech data were collected in a shadowing task with two conditions, one with a full speech signal and one with high-pass filtered speech above 300 Hz. The results showed that perception bias toward fundamental frequency was related to the degree of F0 imitation. The effect was stronger in the condition with high-pass filtered speech. The experimental outcomes suggest advantages for fundamental listeners in communicative situations where F0 imitation is used as a behavioral cue. Future research needs to determine to what extent auditory perception bias may be related to other individual properties known to improve imitation, such as phonetic talent. PMID:24204361
NASA Technical Reports Server (NTRS)
Brenner, Malcolm; Shipp, Thomas
1988-01-01
In a study of the validity of eight candidate voice measures (fundamental frequency, amplitude, speech rate, frequency jitter, amplitude shimmer, Psychological Stress Evaluator scores, energy distribution, and the derived measure of the above measures) for determining psychological stress, 17 males age 21 to 35 were subjected to a tracking task on a microcomputer CRT while parameters of vocal production as well as heart rate were measured. Findings confirm those of earlier studies that increases in fundamental frequency, amplitude, and speech rate are found in speakers involved in extreme levels of stress. In addition, it was found that the same changes appear to occur in a regular fashion within a more subtle level of stress that may be characteristic, for example, of routine flying situations. None of the individual speech measures performed as robustly as did heart rate.
Van So, Pham; Jun, Hyun Woo; Lee, Jaichan
2013-12-01
We have investigated the actuator performance of a piezoelectrically actuated inkjet print head via the numerical and experimental analysis. The actuator consisting of multi-layer membranes, such as piezoelectric, elastic and other buffer layers, and ink chamber was fabricated by MEMS processing. The maximum displacement of the actuator membrane obtained in the experiment is explained by numerical analysis. A simulation of the actuator performance with fluidic damping shows that the resonant frequency of the membrane in liquid is reduced from its resonant frequency in air by a factor of three, which was also verified in the experiment. These simulation and experimental studies demonstrate how much "dynamic force," in terms of a membrane's maximum displacement, maximum force and driving frequency, can be produced by an actuator membrane interacting with fluid.
Cho, Hyunok; Park, Jongcheol; Park, Jae Yeong
2016-05-01
A piezoelectric vibration energy harvester with interdigital shaped cantilever was developed by using silicon bulk micromachining technology. The proposed energy harvester was designed to obtain multi degree-of-freedom (m-DOF). Most of the piezoelectric vibration energy harvesters are comprised of mass-loaded cantilever beams having several resonant frequencies. The second resonant frequency of such a device has lower amplitude compared to its first resonant frequency (fundamental frequency). Therefore, the interdigital shaped cantilever has been proposed for multiple fundamental resonant frequencies. The fabricated piezoelectric vibration energy harvester is composed of main cantilever (MC), sub-main cantilever (SMC), and secondary cantilevers (SC). MC surrounds SMC and SC which have same dimension of 5600 x 800 x 10 μm3. The fabricated piezoelectric energy harvester can generate 51.4 mV(p-p) and 11 mV(p-p) of output voltages at 24.2 Hz and 33 Hz of its resonant frequencies by MC. Moreover, it can generate 8 mV(p-p) and 6.6 mV(p-p) of output voltages at 24.2 Hz and 33.2 Hz of its resonant frequencies by SMC; and 364 mV(p-p) of output voltage at 33.6 Hz of its resonant frequency by SC.
Patient-specific Distraction Regimen to Avoid Growth-rod Failure.
Agarwal, Aakash; Jayaswal, Arvind; Goel, Vijay K; Agarwal, Anand K
2018-02-15
A finite element study to establish the relationship between patient's curve flexibility (determined using curve correction under gravity) in juvenile idiopathic scoliosis and the required distraction frequency to avoid growth rod fracture, as a function of time. To perform a parametric analysis using a juvenile scoliotic spine model (single mid-thoracic curve with the apex at the eighth thoracic vertebra) and establish the relationship between curve flexibility (determined using curve correction under gravity) and the distraction interval that allows a higher factor of safety for the growth rods. Previous studies have shown that frequent distraction with smaller magnitude of distractions are less likely to result in rod failure. However there has not been any methodology or a chart provided to apply this knowledge on to the individual patients that undergo the treatment. This study aims to fill in that gap. The parametric study was performed by varying the material properties of the disc, hence altering the axial stiffness of the scoliotic spine model. The stresses on the rod were found to increase with increased axial stiffness of the spine, and this resulted in the increase of required optimal frequency to achieve a factor of safety of two for growth rods. A relationship between the percentage correction in Cobb's angle due to gravity alone, and the required distraction interval for limiting the maximum von Mises stress to 255 MPa on the growth rods was established. The distraction interval required to limit the stresses to the selected nominal value reduces with increase in stiffness of the spine. Furthermore, the appropriate distraction interval reduces for each model as the spine becomes stiffer with time (autofusion). This points to the fact the optimal distraction frequency is a time-dependent variable that must be achieved to keep the maximum von Mises stress under the specified factor of safety. The current study demonstrates the possibility of translating fundamental information from finite element modeling to the clinical arena, for mitigating the occurrence of growth rod fracture, that is, establishing a relationship between optimal distraction interval and curve flexibility (determined using curve correction under gravity). N/A.
Seismic imaging of Q structures by a trans-dimensional coda-wave analysis
NASA Astrophysics Data System (ADS)
Takahashi, Tsutomu
2017-04-01
Wave scattering and intrinsic attenuation are important processes to describe incoherent and complex wave trains of high frequency seismic wave (>1Hz). The multiple lapse time window analysis (MLTWA) has been used to estimate scattering and intrinsic Q values by assuming constant Q in a study area (e.g., Hoshiba 1993). This study generalizes this MLTWA to estimate lateral variations of Q values under the Bayesian framework in dimension variable space. Study area is partitioned into small areas by means of the Voronoi tessellation. Scattering and intrinsic Q in each small area are constant. We define a misfit function for spatiotemporal variations of wave energy as with the original MLTWA, and maximize the posterior probability with changing not only Q values but the number and spatial layout of the Voronoi cells. This maximization is conducted by means of the reversible jump Markov chain Monte Carlo (rjMCMC) (Green 1995) since the number of unknown parameters (i.e., dimension of posterior probability) is variable. After a convergence to the maximum posterior, we estimate Q structures from the ensemble averages of MCMC samples around the maximum posterior probability. Synthetic tests showed stable reconstructions of input structures with reasonable error distributions. We applied this method for seismic waveform data recorded by ocean bottom seismograms at the outer-rise area off Tohoku, and estimated Q values at 4-8Hz, 8-16Hz and 16-32Hz. Intrinsic Q are nearly constant at all frequency bands, and scattering Q shows two distinct strong scattering regions at petit spot area and high seismicity area. These strong scattering are probably related to magma inclusions and fractured structure, respectively. Difference between these two areas becomes clear at high frequencies. It means that scale dependences of inhomogeneities or smaller scale inhomogeneity is important to discuss medium property and origins of structural variations. While the generalized MLTWA is based on a classical waveform modeling in constant Q medium, this method can be a fundamental basis for Q structure imaging in the crust.
SOI MESFETs on high-resistivity, trap-rich substrates
NASA Astrophysics Data System (ADS)
Mehr, Payam; Zhang, Xiong; Lepkowski, William; Li, Chaojiang; Thornton, Trevor J.
2018-04-01
The DC and RF characteristics of metal-semiconductor field-effect-transistors (MESFETs) on conventional CMOS silicon-on-insulator (SOI) substrates are compared to nominally identical devices on high-resistivity, trap-rich SOI substrates. While the DC transfer characteristics are statistically identical on either substrate, the maximum available gain at GHz frequencies is enhanced by ∼2 dB when using the trap-rich substrates, with maximum operating frequencies, fmax, that are approximately 5-10% higher. The increased fmax is explained by the reduced substrate conduction at GHz frequencies using a lumped-element, small-signal model.
Robillard, Tony; Montealegre-Z, Fernando; Desutter-Grandcolas, Laure; Grandcolas, Philippe; Robert, Daniel
2013-06-01
Sound production in crickets relies on stridulation, the well-understood rubbing together of a pair of specialised wings. As the file of one wing slides over the scraper of the other, a series of rhythmic impacts causes harmonic oscillations, usually resulting in the radiation of pure tones delivered at low frequencies (2-8 kHz). In the short-winged crickets of the Lebinthini tribe, acoustic communication relies on signals with remarkably high frequencies (>8 kHz) and rich harmonic content. Using several species of the subfamily Eneopterinae, we characterised the morphological and mechanical specialisations supporting the production of high frequencies, and demonstrated that higher harmonics are exploited as dominant frequencies. These specialisations affect the structure of the stridulatory file, the motor control of stridulation and the resonance of the sound radiator. We placed these specialisations in a phylogenetic framework and show that they serve to exploit high-frequency vibrational modes pre-existing in the phylogenetic ancestor. In Eneopterinae, the lower frequency components are harmonically related to the dominant peak, suggesting they are relicts of ancestral carrier frequencies. Yet, such ghost frequencies still occur in the wings' free resonances, highlighting the fundamental mechanical constraints of sound radiation. These results support the hypothesis that such high-frequency songs evolved stepwise, by a form of punctuated evolution that could be related to functional constraints, rather than by only the progressive increase of the ancestral fundamental frequency.
Fundamental Characterization of Spanwise Loading and Trailed Wake Vortices
2016-07-01
the close interaction of the tip vortex with a following blade . Such vortex interactions are fundamental determinants of rotor performance, loads, and...wing loading distribution differs from a typical loading on a hovering rotor blade in that the maximum bound circulation occurs at the blade root...and not close to the tip; this is similar to a very highly twisted rotor blade , like a tilt-rotor, in hover. The wing-vortex interaction alters the
NASA Astrophysics Data System (ADS)
Lopez-Baeza, E.; Monsoriu Torres, A.; Font, J.; Alonso, O.
2009-04-01
The ESA SMOS (Soil Moisture and Ocean Salinity) Mission is planned to be launched in July 2009. The satellite will measure soil moisture over the continents and surface salinity of the oceans at resolutions that are sufficient for climatological-type studies. This paper describes the procedure to be used at the Spanish SMOS Level 3 and 4 Data Processing Centre (CP34) to generate Soil Moisture and other Land Surface Product maps from SMOS Level 2 data. This procedure can be used to map Soil Moisture, Vegetation Water Content and Soil Dielectric Constant data into different pre-defined spatial grids with fixed temporal frequency. The L3 standard Land Surface Products to be generated at CP34 are: Soil Moisture products: maximum spatial resolution with no spatial averaging, temporal averaging of 3 days, daily generation maximum spatial resolution with no spatial averaging, temporal averaging of 10 days, generation frequency of once every 10 days. b': maximum spatial resolution with no spatial averaging, temporal averaging of monthly decades (1st to 10th of the month, 11th to 20th of the month, 21st to last day of the month), generation frequency of once every decade monthly average, temporal averaging from L3 decade averages, monthly generation Seasonal average, temporal averaging from L3 monthly averages, seasonally generation yearly average, temporal averaging from L3 monthly averages, yearly generation Vegetation Water Content products: maximum spatial resolution with no spatial averaging, temporal averaging of 10 days, generation frequency of once every 10 days. a': maximum spatial resolution with no spatial averaging, temporal averaging of monthly decades (1st to 10th of the month, 11th to 20th of the month, 21st to last day of the month) using simple averaging method over the L2 products in ISEA grid, generation frequency of once every decade monthly average, temporal averaging from L3 decade averages, monthly generation seasonal average, temporal averaging from L3 monthly averages, seasonally generation yearly average, temporal averaging from L3 monthly averages, yearly generation Dielectric Constant products: (the dielectric constant products are delivered together with soil moisture products, with the same averaging periods and generation frequency): maximum spatial resolution with no spatial averaging, temporal averaging of 3 days, daily generation maximum spatial resolution with no spatial averaging, temporal averaging of 10 days, generation frequency of once every 10 days. b': maximum spatial resolution with no spatial averaging, temporal averaging of monthly decades (1st to 10th of the month, 11th to 20th of the month, 21st to last day of the month), generation frequency of once every decade monthly average, temporal averaging from L3 decade averages, monthly generation seasonal average, temporal averaging from L3 monthly averages, seasonally generation yearly average, temporal averaging from L3 monthly averages, yearly generation.
Reyes-Valdés, M H; Stelly, D M
1995-01-01
Frequencies of meiotic configurations in cytogenetic stocks are dependent on chiasma frequencies in segments defined by centromeres, breakpoints, and telomeres. The expectation maximization algorithm is proposed as a general method to perform maximum likelihood estimations of the chiasma frequencies in the intervals between such locations. The estimates can be translated via mapping functions into genetic maps of cytogenetic landmarks. One set of observational data was analyzed to exemplify application of these methods, results of which were largely concordant with other comparable data. The method was also tested by Monte Carlo simulation of frequencies of meiotic configurations from a monotelodisomic translocation heterozygote, assuming six different sample sizes. The estimate averages were always close to the values given initially to the parameters. The maximum likelihood estimation procedures can be extended readily to other kinds of cytogenetic stocks and allow the pooling of diverse cytogenetic data to collectively estimate lengths of segments, arms, and chromosomes. Images Fig. 1 PMID:7568226
Mobinizadeh, Mohammadreza; Raeissi, Pouran; Nasiripour, Amir Ashkan; Olyaeemanesh, Alireza; Tabibi, Seyed Jamaleddin
2016-01-01
Background: In the recent years, using health technologies to diagnose and treat diseases has had a considerable and accelerated growth. The proper use of these technologies may considerably help in the diagnosis and treatment of different diseases. On the other hand, unlimited and unrestricted entry of these technologies may result in induced demand by service providers. The aim of this study was to determine the appropriate criteria used in health technologies priority-setting models in the world. Methods: Using MESH and free text, we sought and retrieved the relevant articles from the most appropriate medical databases (the Cochrane Library, PubMed and Scopus) through three separate search strategies up to March 2015. The inclusion criteria were as follows: 1) Studies with specific criteria; 2) Articles written in English; 3) Those articles conducted in compliance with priority setting of health technologies. Data were analyzed qualitatively using a thematic synthesis technique. Results: After screening the retrieved papers via PRISMA framework, from the 7,012 papers, 40 studies were included in the final phase. Criteria for selecting health technologies (in pre assessment and in the assessment phase) were categorized into six main themes: 1) Health outcomes; 2) Disease and target population; 3) Technology alternatives; 4) Economic aspects; 5) Evidence; 6) and other factors. "Health effects/benefits" had the maximum frequency in health outcomes (8 studies); "disease severity" had the maximum frequency in disease and target population (12 studies); "the number of alternatives" had the maximum frequency in alternatives (2 studies); "cost-effectiveness" had the maximum frequency in economic aspects (15 studies); "quality of evidence" had the maximum frequency in evidence (4 studies); and "issues concerning the health system" had the maximum frequency in other factors (10 studies). Conclusion: The results revealed an increase in the number of studies on health technologies priority setting around the world, and emphasized the necessity of application of a multi- criteria approach for appropriate decision making about healthcare technologies in the health systems. PMID:27390699
Kunduk, Melda; Vansant, Mathew B; Ikuma, Takeshi; McWhorter, Andrew
2017-03-01
This study investigated the effect of menstrual cycle on vocal fold vibratory characteristics in young women using high-speed digital imaging. This study examined the menstrual phase effect on five objective high-speed imaging parameters and two self-rated perceptual parameters. The effects of oral birth control use were also investigated. Thirteen subjects with no prior voice complaints were included in this study. All data were collected at three different time periods (premenses, postmenses, ovulation) over the course of one menstrual cycle. For five of the 13 subjects, data were collected for two consecutive cycles. Six of 13 subjects were oral birth control users. From high-speed imaging data, five objective parameters were computed: fundamental frequency, fundamental frequency deviation, harmonics-to-noise ratio, harmonic richness factor, and ratio of first and second harmonics. They were supplemented by two self-rated parameters: Reflux Severity Index and perceptual voice quality rating. Analysis included mixed model linear analysis with repeated measures. Results indicated no significant main effects for menstrual phase, between-cycle, or birth control use in the analysis for mean fundamental frequency, fundamental frequency deviation, harmonics-to-noise ratio, harmonic richness factor, first and second harmonics, Reflux Severity Index, and perceptual voice quality rating. Additionally, there were no interaction effects. Hormone fluctuations observed across the menstrual cycle do not appear to have direct effect on vocal fold vibratory characteristics in young women with no voice concerns. Birth control use, on the other hand, may have influence on spectral richness of vocal fold vibration. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Pulse register phonation in Diana monkey alarm calls
NASA Astrophysics Data System (ADS)
Riede, Tobias; Zuberbühler, Klaus
2003-05-01
The adult male Diana monkeys (Cercopithecus diana) produce predator-specific alarm calls in response to two of their predators, the crowned eagles and the leopards. The acoustic structure of these alarm calls is remarkable for a number of theoretical and empirical reasons. First, although pulsed phonation has been described in a variety of mammalian vocalizations, very little is known about the underlying production mechanism. Second, Diana monkey alarm calls are based almost exclusively on this vocal production mechanism to an extent that has never been documented in mammalian vocal behavior. Finally, the Diana monkeys' pulsed phonation strongly resembles the pulse register in human speech, where fundamental frequency is mainly controlled by subglottal pressure. Here, we report the results of a detailed acoustic analysis to investigate the production mechanism of Diana monkey alarm calls. Within calls, we found a positive correlation between the fundamental frequency and the pulse amplitude, suggesting that both humans and monkeys control fundamental frequency by subglottal pressure. While in humans pulsed phonation is usually considered pathological or artificial, male Diana monkeys rely exclusively on pulsed phonation, suggesting a functional adaptation. Moreover, we were unable to document any nonlinear phenomena, despite the fact that they occur frequently in the vocal repertoire of humans and nonhumans, further suggesting that the very robust Diana monkey pulse production mechanism has evolved for a particular functional purpose. We discuss the implications of these findings for the structural evolution of Diana monkey alarm calls and suggest that the restricted variability in fundamental frequency and robustness of the source signal gave rise to the formant patterns observed in Diana monkey alarm calls, used to convey predator information.
Fundamentals of dielectric properties measurements and agricultural applications.
Nelson, Stuart O
2010-01-01
Dielectrics and dielectric properties are defined generally and dielectric measurement methods and equipment are described for various frequency ranges from audio frequencies through microwave frequencies. These include impedance and admittance bridges, resonant frequency, transmission-line, and free-space methods in the frequency domain and time-domain and broadband techniques. Many references are cited describing methods in detail and giving sources of dielectric properties data. Finally a few applications for such data are presented and sources of tabulated and dielectric properties data bases are identified.
Guidelines for Selecting Microphones for Human Voice Production Research
ERIC Educational Resources Information Center
Svec, Jan G.; Granqvist, Svante
2010-01-01
Purpose: This tutorial addresses fundamental characteristics of microphones (frequency response, frequency range, dynamic range, and directionality), which are important for accurate measurements of voice and speech. Method: Technical and voice literature was reviewed and analyzed. The following recommendations on desirable microphone…
NASA Astrophysics Data System (ADS)
Zhang, Yujia; Yilmaz, Alper
2016-06-01
Surface reconstruction using coded structured light is considered one of the most reliable techniques for high-quality 3D scanning. With a calibrated projector-camera stereo system, a light pattern is projected onto the scene and imaged by the camera. Correspondences between projected and recovered patterns are computed in the decoding process, which is used to generate 3D point cloud of the surface. However, the indirect illumination effects on the surface, such as subsurface scattering and interreflections, will raise the difficulties in reconstruction. In this paper, we apply maximum min-SW gray code to reduce the indirect illumination effects of the specular surface. We also analysis the errors when comparing the maximum min-SW gray code and the conventional gray code, which justifies that the maximum min-SW gray code has significant superiority to reduce the indirect illumination effects. To achieve sub-pixel accuracy, we project high frequency sinusoidal patterns onto the scene simultaneously. But for specular surface, the high frequency patterns are susceptible to decoding errors. Incorrect decoding of high frequency patterns will result in a loss of depth resolution. Our method to resolve this problem is combining the low frequency maximum min-SW gray code and the high frequency phase shifting code, which achieves dense 3D reconstruction for specular surface. Our contributions include: (i) A complete setup of the structured light based 3D scanning system; (ii) A novel combination technique of the maximum min-SW gray code and phase shifting code. First, phase shifting decoding with sub-pixel accuracy. Then, the maximum min-SW gray code is used to resolve the ambiguity resolution. According to the experimental results and data analysis, our structured light based 3D scanning system enables high quality dense reconstruction of scenes with a small number of images. Qualitative and quantitative comparisons are performed to extract the advantages of our new combined coding method.
Code of Federal Regulations, 2013 CFR
2013-10-01
... to change frequency, power, location or emission. Each application must include the FAA Regional... 5031.0 MHz for microwave landing systems. Additionally, the frequencies in paragraph (b) of this... following conditions apply: (i) The maximum power authorized on the frequencies 108.150 and 334.550 MHz is 1...
Code of Federal Regulations, 2012 CFR
2012-10-01
... to change frequency, power, location or emission. Each application must include the FAA Regional... 5031.0 MHz for microwave landing systems. Additionally, the frequencies in paragraph (b) of this... following conditions apply: (i) The maximum power authorized on the frequencies 108.150 and 334.550 MHz is 1...
Trepakov, V. A.; Kvyatkovskii, O. E.; Savinov, M. E.; ...
2016-10-01
The unusual behavior of the low-frequency (10 Hz–1 MHz) permittivity in single crystals of ferroelectric multiferroic TbMnO3 has been experimentally and theoretically studied in detail in the region of the narrow temperature peak of the permittivity, associated with the ferroelectric phase transition (T C ~ 27.4 K). It has been found that the ε c(ω, T) maximum sharply decreases with increasing measured field frequency, while the temperature position of the maximum is independent of frequency. It has been shown that the observed features of the polarization response can be satisfactorily described within the Landau–Khalatnikov polarization relaxation theory.
A Fundamental Relationship Between Genotype Frequencies and Fitnesses
Lachance, Joseph
2008-01-01
The set of possible postselection genotype frequencies in an infinite, randomly mating population is found. Geometric mean heterozygote frequency divided by geometric mean homozygote frequency equals two times the geometric mean heterozygote fitness divided by geometric mean homozygote fitness. The ratio of genotype frequencies provides a measure of genetic variation that is independent of allele frequencies. When this ratio does not equal two, either selection or population structure is present. Within-population HapMap data show population-specific patterns, while pooled data show an excess of homozygotes. PMID:18780726
Suspension osteopenia in mice: Whole body electromagnetic field effects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simske, S.J.; Luttges, M.W.
1995-08-01
Whole-body fields were tested for their efficacy in preventing the osteopenia caused by tail suspension in mice. The fields had fundamental frequencies corresponding to the upper range of predicted endogenous impact-generated frequencies (0.25--2.0 kHz) in the long bones. Three distinct whole-body EMFs were applied for 2 weeks on growing mice. Structural, geometric, and material properties of the femora, tibiae, and humeri of suspended mice were altered compared to controls. Comparison of suspended mice and mice subjected to caloric restriction indicates that the changes in caloric intake do not explain either the suspension or the field-induced effects. In agreement with pastmore » studies, rather, unloading appears to cause the suspension effects and to be addressed by the EMFs. The EMF effects on bone properties were apparently frequency dependent, with the lower two fundamental frequencies (260 and 910 Hz) altering, albeit slightly, the suspension-induced bone effects. The fields are not apparently optimized for frequency, etc., with respect to therapeutic potential; however, suspension provides a model system for further study of the in vivo effects of EMFs.« less
Microstrip patch antenna for simultaneous strain and temperature sensing
NASA Astrophysics Data System (ADS)
Mbanya Tchafa, F.; Huang, H.
2018-06-01
A patch antenna, consisting of a radiation patch, a dielectric substrate, and a ground plane, resonates at distinct fundamental frequencies that depend on the substrate dielectric constant and the dimensions of the radiation patch. Since these parameters change with the applied strain and temperature, this study investigates simultaneous strain and temperature sensing using a single antenna that has two fundamental resonant frequencies. The theoretical relationship between the antenna resonant frequency shifts, the temperature, and the applied strain was first established to guide the selection of the dielectric substrate, based on which an antenna sensor with a rectangular radiation patch was designed and fabricated. A tensile test specimen instrumented with the antenna sensor was subjected to thermo-mechanical tests. Experiment results validated the theoretical predictions that the normalized antenna resonant frequency shifts are linearly proportional to the applied strain and temperature changes. An inverse method was developed to determine the strain and temperature changes from the normalized antenna resonant frequency shifts, yielding measurement uncertainty of 0.4 °C and 17.22 μ \\varepsilon for temperature and strain measurement, respectively.
Suspension osteopenia in mice: whole body electromagnetic field effects.
Simske, S J; Luttges, M W
1995-01-01
Whole-body fields were tested for their efficacy in preventing the osteopenia caused by tail suspension in mice. The fields had fundamental frequencies corresponding to the upper range of predicted endogenous impact-generated frequencies (0.25-2.0 kHz) in the long bones. Three distinct whole-body EMFs were applied for 2 weeks on growing mice. Structural, geometric, and material properties of the femora, tibiae, and humeri of suspended mice were altered compared to controls. Comparison of suspended mice and mice subjected to caloric restriction indicates that the changes in caloric intake do not explain either the suspension or the field-induced effects. In agreement with past studies, rather, unloading appears to cause the suspension effects and to be addressed by the EMFs. The EMF effects on bone properties were apparently frequency dependent, with the lower two fundamental frequencies (260 and 910 Hz) altering, albeit slightly, the suspension-induced bone effects. The fields are not apparently optimized for frequency, etc., with respect to therapeutic potential; however, suspension provides a model system for further study of the in vivo effects of EMFs.
The natural frequencies of symmetric angle-ply laminates derived from eigensensitivity analysis
NASA Technical Reports Server (NTRS)
Reiss, Robert; Ramachandran, S.; Qian, BO
1988-01-01
In this paper, a new closed-form approximate solution for the natural frequencies of symmetric rectangular angle-ply laminates simply supported on all four edges is derived. The solution, obtained from eigensensitivity analysis, is expressed as a truncated Fourier series in the ply angle. Results show that the prediction for the fundamental frequency is quite accurate for engineering applications, often within 1-2 percent of the true frequency.
A general scaling law reveals why the largest animals are not the fastest.
Hirt, Myriam R; Jetz, Walter; Rall, Björn C; Brose, Ulrich
2017-08-01
Speed is the fundamental constraint on animal movement, yet there is no general consensus on the determinants of maximum speed itself. Here, we provide a general scaling model of maximum speed with body mass, which holds across locomotion modes, ecosystem types and taxonomic groups. In contrast to traditional power-law scaling, we predict a hump-shaped relationship resulting from a finite acceleration time for animals, which explains why the largest animals are not the fastest. This model is strongly supported by extensive empirical data (474 species, with body masses ranging from 30 μg to 100 tonnes) from terrestrial as well as aquatic ecosystems. Our approach unravels a fundamental constraint on the upper limit of animal movement, thus enabling a better understanding of realized movement patterns in nature and their multifold ecological consequences.
Mehlstäubler, Tanja E; Grosche, Gesine; Lisdat, Christian; Schmidt, Piet O; Denker, Heiner
2018-06-01
We review experimental progress on optical atomic clocks and frequency transfer, and consider the prospects of using these technologies for geodetic measurements. Today, optical atomic frequency standards have reached relative frequency inaccuracies below 10 -17 , opening new fields of fundamental and applied research. The dependence of atomic frequencies on the gravitational potential makes atomic clocks ideal candidates for the search for deviations in the predictions of Einstein's general relativity, tests of modern unifying theories and the development of new gravity field sensors. In this review, we introduce the concepts of optical atomic clocks and present the status of international clock development and comparison. Besides further improvement in stability and accuracy of today's best clocks, a large effort is put into increasing the reliability and technological readiness for applications outside of specialized laboratories with compact, portable devices. With relative frequency uncertainties of 10 -18 , comparisons of optical frequency standards are foreseen to contribute together with satellite and terrestrial data to the precise determination of fundamental height reference systems in geodesy with a resolution at the cm-level. The long-term stability of atomic standards will deliver excellent long-term height references for geodetic measurements and for the modelling and understanding of our Earth.
A Discussion of Zero Spring Rate Mechanisms Used for the Active Isolation Mount Experiment
NASA Technical Reports Server (NTRS)
Teter, John E., Jr.
1999-01-01
In the summer of 1995 the Structural Dynamics Branch at NASA Langley Research Center set out to conceive a small, lightweight, low frequency isolation mount that could be used for spaceflight experiments. The Engineering Design Branch undertook the task of developing the isolation mount. This report describes the engineering process that led to three phases of a study entitled "Active Isolation Mounts" (AIM). A zero spring rate mechanism was used to achieve low fundamental frequencies for a payloads in the 1 to 10 pound range. It worked by balancing both a positive and a negative stiffness so that the net result was a small positive stiffness. The study demonstrated devices that could reduce the initial corner frequency by a factor of six for brief periods and a factor of two for extended periods. The designs were relatively simple and minimized weight, volume, and power. They could be scaled down and they were made of spaceflight compatible materials. All designs offered the ability to continuously vary the fundamental frequency. Yet, the goal of reducing the frequency by an order of magnitude was not achieved because the systems were too unstable at low frequencies. There was a trade between performance and stability.
NASA Astrophysics Data System (ADS)
Mehlstäubler, Tanja E.; Grosche, Gesine; Lisdat, Christian; Schmidt, Piet O.; Denker, Heiner
2018-06-01
We review experimental progress on optical atomic clocks and frequency transfer, and consider the prospects of using these technologies for geodetic measurements. Today, optical atomic frequency standards have reached relative frequency inaccuracies below 10‑17, opening new fields of fundamental and applied research. The dependence of atomic frequencies on the gravitational potential makes atomic clocks ideal candidates for the search for deviations in the predictions of Einstein’s general relativity, tests of modern unifying theories and the development of new gravity field sensors. In this review, we introduce the concepts of optical atomic clocks and present the status of international clock development and comparison. Besides further improvement in stability and accuracy of today’s best clocks, a large effort is put into increasing the reliability and technological readiness for applications outside of specialized laboratories with compact, portable devices. With relative frequency uncertainties of 10‑18, comparisons of optical frequency standards are foreseen to contribute together with satellite and terrestrial data to the precise determination of fundamental height reference systems in geodesy with a resolution at the cm-level. The long-term stability of atomic standards will deliver excellent long-term height references for geodetic measurements and for the modelling and understanding of our Earth.
Broadband midinfrared frequency comb with tooth scanning
NASA Astrophysics Data System (ADS)
Lee, Kevin F.; Masłowski, P.; Mills, A.; Mohr, C.; Jiang, Jie; Schunemann, Peter G.; Fermann, M. E.
2015-03-01
Frequency combs are a massively parallel source of extremely accurate optical frequencies. Frequency combs generally operate at the visible or near-infrared wavelengths, but fundamental molecular vibrations occur at midinfrared wavelengths. We demonstrate an optically-referenced, broadband midinfrared frequency comb based on a doublyresonant optical parametric oscillator (OPO). By tuning the wavelength of the reference laser, the comb line frequencies are tuned as well. By scanning the reference wavelength, any frequency can be accessed, not just the frequencies of the base comb. Combined with our comb-resolving Fourier transform spectrometer, we can measure 200 wavenumber wide broadband absorption spectra with 200 kHz linewidth comb teeth. Our OPO is pumped by an amplified Tm fiber frequency comb, with phase-locked carrier envelope offset frequency, and repetition rate fixed by phase-locking a frequency comb line to a narrow linewidth diode laser at a telecom channel. The frequency comb is referenced to GPS by long-term stabilization of the repetition rate to a selected value using the temperature of the reference laser as the control. The resulting pump comb is about 3W of 100 fs pulses at 418 MHz repetition rate at 1950 nm. Part of the comb is used for supercontinuum generation for frequency stabilization, and the rest pumps an orientation-patterned gallium arsenide (OP-GaAs) crystal in a doubly-resonant optical parametric oscillator cavity, yielding collinear signal and idler beams from about 3 to 5.5 μm. We verify comb scanning by resolving the 200 MHz wide absorption lines of the entire fundamental CO vibrational manifold at 11 Torr pressure.
Free Vibration of Uncertain Unsymmetrically Laminated Beams
NASA Technical Reports Server (NTRS)
Kapania, Rakesh K.; Goyal, Vijay K.
2001-01-01
Monte Carlo Simulation and Stochastic FEA are used to predict randomness in the free vibration response of thin unsymmetrically laminated beams. For the present study, it is assumed that randomness in the response is only caused by uncertainties in the ply orientations. The ply orientations may become random or uncertain during the manufacturing process. A new 16-dof beam element, based on the first-order shear deformation beam theory, is used to study the stochastic nature of the natural frequencies. Using variational principles, the element stiffness matrix and mass matrix are obtained through analytical integration. Using a random sequence a large data set is generated, containing possible random ply-orientations. This data is assumed to be symmetric. The stochastic-based finite element model for free vibrations predicts the relation between the randomness in fundamental natural frequencies and the randomness in ply-orientation. The sensitivity derivatives are calculated numerically through an exact formulation. The squared fundamental natural frequencies are expressed in terms of deterministic and probabilistic quantities, allowing to determine how sensitive they are to variations in ply angles. The predicted mean-valued fundamental natural frequency squared and the variance of the present model are in good agreement with Monte Carlo Simulation. Results, also, show that variations between plus or minus 5 degrees in ply-angles can affect free vibration response of unsymmetrically and symmetrically laminated beams.
An Accurate ab initio Quartic Force Field and Vibrational Frequencies for CH4 and Isotopomers
NASA Technical Reports Server (NTRS)
Lee, Timothy J.; Martin, Jan M. L.; Taylor, Peter R.
1995-01-01
A very accurate ab initio quartic force field for CH4 and its isotopomers is presented. The quartic force field was determined with the singles and doubles coupled-cluster procedure that includes a quasiperturbative estimate of the effects of connected triple excitations, CCSD(T), using the correlation consistent polarized valence triple zeta, cc-pVTZ, basis set. Improved quadratic force constants were evaluated with the correlation consistent polarized valence quadruple zeta, cc-pVQZ, basis set. Fundamental vibrational frequencies are determined using second-order perturbation theory anharmonic analyses. All fundamentals of CH4 and isotopomers for which accurate experimental values exist and for which there is not a large Fermi resonance, are predicted to within +/- 6 cm(exp -1). It is thus concluded that our predictions for the harmonic frequencies and the anharmonic constants are the most accurate estimates available. It is also shown that using cubic and quartic force constants determined with the correlation consistent polarized double zeta, cc-pVDZ, basis set in conjunction with the cc-pVQZ quadratic force constants and equilibrium geometry leads to accurate predictions for the fundamental vibrational frequencies of methane, suggesting that this approach may be a viable alternative for larger molecules. Using CCSD(T), core correlation is found to reduce the CH4 r(e), by 0.0015 A. Our best estimate for r, is 1.0862 +/- 0.0005 A.
An Analysis of the Computer System Chargeback Concept in the Naval Industrial Fund Environment.
1983-06-01
fundamental questions be answered, i.e., How much money and time should be spent on the control system ? How should the resources be deployed for maximum...context of the defined control structure and -he corresponding measures cf performance by which management will be judged. Fundamentally , the control system ...THESIS -E2 AN ANALYSIS OF THE COMPUTER SYSTEM CHARGEBACK CONCEPT IN THE NAVAL INDUSTRIAL FUND ENVIRONMENT by Terry D. Schechinger Arthur E. Prack Ill
Solar activity cycles: indication of the existence of fundamental symmetry?
NASA Astrophysics Data System (ADS)
Dreschhoff, Gisela; Wong, Kai Wai; Curatolo, Susana; Jungner, Hogne; Perry, Charles
Previous work has shown that there is a consistent pattern that seems to be underlying the various known solar activity cycles, which is fundamentally based on the nuclear magnetic resonance frequencies (NMR) of some of the main isotopic constituents within the solar core, hydrogen-1 F(H-1)NMR and helium-3 F(He-3)NMR [1], and resulting in a so-called "beat-frequency", thereby suggesting that this mechanism may involve the entire Sun. Furthermore, it was found that the energy generating region of the Sun may be governed by an optimum condition where F(He-3)NMR = F(H-1)NMR associated with an internal magnetic field of 7 Gauss, and the beat-frequency Fbeat representing the Schwabe periodicity [2]. Using the Schwabe cycle as the basic cycle length (C2), the astronomical and geophysical data (solar activity cycles C1) are represented by a fundamental harmonic progression of the form C1 = C2 x 2n. We will attempt to show that this type of harmonic progression can be viewed as being part of fundamental principles of nature, as they are evident in the mathematical expression of 2n matrices in group representations SU(n), or the superposition of two states of one particle 21, two states of two (or n) particles leading to 22 (or 2n ) possible combinations. We may show that these fundamental principles are linked to the newly developed 5D projection field theory and the realization of matter as proposed by Wong [3]. [1] C.A. Perry, Thesis 1989, University of Kansas [2] G. Dreschhoff, Adv. Space Res., 40, p. 1015-1020, 2007 [3] K.W. Wong, Nova Science, 2009, in press
A New Cloud and Aerosol Layer Detection Method Based on Micropulse Lidar Measurements
NASA Astrophysics Data System (ADS)
Wang, Q.; Zhao, C.; Wang, Y.; Li, Z.; Wang, Z.; Liu, D.
2014-12-01
A new algorithm is developed to detect aerosols and clouds based on micropulse lidar (MPL) measurements. In this method, a semi-discretization processing (SDP) technique is first used to inhibit the impact of increasing noise with distance, then a value distribution equalization (VDE) method is introduced to reduce the magnitude of signal variations with distance. Combined with empirical threshold values, clouds and aerosols are detected and separated. This method can detect clouds and aerosols with high accuracy, although classification of aerosols and clouds is sensitive to the thresholds selected. Compared with the existing Atmospheric Radiation Measurement (ARM) program lidar-based cloud product, the new method detects more high clouds. The algorithm was applied to a year of observations at both the U.S. Southern Great Plains (SGP) and China Taihu site. At SGP, the cloud frequency shows a clear seasonal variation with maximum values in winter and spring, and shows bi-modal vertical distributions with maximum frequency at around 3-6 km and 8-12 km. The annual averaged cloud frequency is about 50%. By contrast, the cloud frequency at Taihu shows no clear seasonal variation and the maximum frequency is at around 1 km. The annual averaged cloud frequency is about 15% higher than that at SGP.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Visser, P. J. de, E-mail: p.j.devisser@tudelft.nl; Yates, S. J. C.; Guruswamy, T.
2015-06-22
We have measured the absorption of terahertz radiation in a BCS superconductor over a broad range of frequencies from 200 GHz to 1.1 THz, using a broadband antenna-lens system and a tantalum microwave resonator. From low frequencies, the response of the resonator rises rapidly to a maximum at the gap edge of the superconductor. From there on, the response drops to half the maximum response at twice the pair-breaking energy. At higher frequencies, the response rises again due to trapping of pair-breaking phonons in the superconductor. In practice, this is a measurement of the frequency dependence of the quasiparticle creationmore » efficiency due to pair-breaking in a superconductor. The efficiency, calculated from the different non-equilibrium quasiparticle distribution functions at each frequency, is in agreement with the measurements.« less
Experimental and numerical investigation of tissue harmonic imaging (THI)
NASA Astrophysics Data System (ADS)
Jing, Yuan; Yang, Xinmai; Cleveland, Robin O.
2003-04-01
In THI the probing ultrasonic pulse has enough amplitude that it undergoes nonlinear distortion and energy shifts from the fundamental frequency of the pulse into its higher harmonics. Images generated from the second harmonic (SH) have superior quality to the images formed from the fundamental frequency. Experiments with a single element focused ultrasound transducer were used to compare a line target embedded in a tissue phantom using either fundamental or SH imaging. SH imaging showed an improvement in both the axial resolution (0.70 mm vs 0.92 mm) and the lateral resolution (1.02 mm vs 2.70 mm) of the target. In addition, the contrast-to-tissue ratio of the target was 2 dB higher with SH imaging. A three-dimensional model of the forward propagation has been developed to simulate the experimental system. The model is based on a time-domain code for solving the KZK equation and accounts for arbitrary spatial variations in all tissue properties. The code was used to determine the impact of a nearfield layer of fat on the fundamental and second harmonic signals. For a 15 mm thick layer the SH side-lobes remained the same but the fundamental side-lobes increased by 2 dB. [Work supported by the NSF through the Center for Subsurface Sensing and Imaging Systems.
Caberlotto, Elisa; Ruiz, Laetitia; Miller, Zane; Poletti, Mickael; Tadlock, Lauri
2017-01-01
Mechanical and geometrical cues influence cell behaviour. At the tissue level, almost all organs exhibit immediate mechanical responsiveness, in particular by increasing their stiffness in direct proportion to an applied mechanical stress. It was recently shown in cultured-cell models, in particular with fibroblasts, that the frequency of the applied stress is a fundamental stimulating parameter. However, the influence of the stimulus frequency at the tissue level has remained elusive. Using a device to deliver an oscillating torque that generates cyclic strain at different frequencies, we studied the effect(s) of mild skin massage in an ex vivo model and in vivo. Skin explants were maintained ex vivo for 10 days and massaged twice daily for one minute at various frequencies within the range of 65-85 Hz. Biopsies were analysed at D0, D5 and D10 and processed for immuno-histological staining specific to various dermal proteins. As compared to untreated skin explants, the massaging procedure clearly led to higher rates of expression, in particular for decorin, fibrillin, tropoelastin, and procollagen-1. The mechanical stimulus thus evoked an anti-aging response. Strikingly, the expression was found to depend on the stimulus frequency with maximum expression at 75Hz. We then tested whether this mechanical stimulus had an anti-aging effect in vivo. Twenty Caucasian women (aged 65-75y) applied a commercial anti-aging cream to the face and neck, followed by daily treatments using the anti-aging massage device for 8 weeks. A control group of twenty-two women, with similar ages to the first group, applied the cream alone. At W0, W4 and W8, a blinded evaluator assessed the global facial wrinkles, skin texture, lip area, cheek wrinkles, neck sagging and neck texture using a clinical grading scale. We found that combining the massaging device with a skin anti-aging formulation amplified the beneficial effects of the cream.
Caberlotto, Elisa; Ruiz, Laetitia; Miller, Zane; Poletti, Mickael; Tadlock, Lauri
2017-01-01
Mechanical and geometrical cues influence cell behaviour. At the tissue level, almost all organs exhibit immediate mechanical responsiveness, in particular by increasing their stiffness in direct proportion to an applied mechanical stress. It was recently shown in cultured-cell models, in particular with fibroblasts, that the frequency of the applied stress is a fundamental stimulating parameter. However, the influence of the stimulus frequency at the tissue level has remained elusive. Using a device to deliver an oscillating torque that generates cyclic strain at different frequencies, we studied the effect(s) of mild skin massage in an ex vivo model and in vivo. Skin explants were maintained ex vivo for 10 days and massaged twice daily for one minute at various frequencies within the range of 65–85 Hz. Biopsies were analysed at D0, D5 and D10 and processed for immuno-histological staining specific to various dermal proteins. As compared to untreated skin explants, the massaging procedure clearly led to higher rates of expression, in particular for decorin, fibrillin, tropoelastin, and procollagen-1. The mechanical stimulus thus evoked an anti-aging response. Strikingly, the expression was found to depend on the stimulus frequency with maximum expression at 75Hz. We then tested whether this mechanical stimulus had an anti-aging effect in vivo. Twenty Caucasian women (aged 65-75y) applied a commercial anti-aging cream to the face and neck, followed by daily treatments using the anti-aging massage device for 8 weeks. A control group of twenty-two women, with similar ages to the first group, applied the cream alone. At W0, W4 and W8, a blinded evaluator assessed the global facial wrinkles, skin texture, lip area, cheek wrinkles, neck sagging and neck texture using a clinical grading scale. We found that combining the massaging device with a skin anti-aging formulation amplified the beneficial effects of the cream. PMID:28249037
Potential Application of Environmental Noise Recordings in Geoarchaeological Site Characterization
NASA Astrophysics Data System (ADS)
Di Luzio, E.
2015-12-01
Environmental noise recordings are commonly applied in seismic microzonation studies. By calculating the H/V spectral ratio, the fundamental frequency of soft terrains overlying a rigid bedrock can be determined (Nakamura (1989). In such a simple two-layer system, equation f = n Vs/4H (1) links the resonance frequency "f" to the thickness "H" and shear waves velocity "Vs "of the resonating layer. In recent years, this methodology has been applied generally to obtain information on the seismostratigraphy of an investigated site in different environmental context. In this work, its potential application in the characterization of archaeological features hosted in shallow geological levels is discussed. Field cases are identified in the Appia Antica archaeological site which is placed in central Italy. Here, acknowledged targets correspond to: i) empty tanks carved by the Romans into Cretaceous limestone in the IV-III cen. BC and ii): the basaltic stone paving of the ancient road track which is locally buried beneath colluvial deposits. Narrowly-spaced recordings of environmental noise were carried using a portable digital seismograph equipped with three electrodynamic orthogonal sensors (velocimeters) responding in the band 0.1 ÷1024 Hz and adopting a sampling frequency of 256 Hz.. Results are discussed in terms of absolute H/V values and related distribution maps in the very high-frequency interval of 10-40Hz. In the tanks hosting area, interpolation of H/V maximum values around 13Hz matches caves location and alignment, which is also evidenced by clear inversions (H/V<1) at lower frequencies (10-1Hz). Correlation between H/V peaks and the top surface of the buried stone paving along the prosecution of the road track is even more straightforward. Finally, the depth variations of the tank roofs and the basaltic paving were reconstructed combining in equation (1) results of noise recordings with borehole data and geophysical surveys (SASW analysis).
Features of tuned mass damper behavior under strong earthquakes
NASA Astrophysics Data System (ADS)
Nesterova, Olga; Uzdin, Alexander; Fedorova, Maria
2018-05-01
Plastic deformations, cracks and destruction of structure members appear in the constructions under strong earthquakes. Therefore constructions are characterized by a nonlinear deformation diagram. Two types of construction non-linearity are considered in the paper. The first type of nonlinearity is elastoplastic one. In this case, plastic deformations occur in the structural elements, and when the element is unloaded, its properties restores. Among such diagrams are the Prandtl diagram, the Prandtl diagram with hardening, the Ramberg-Osgood diagram and others. For systems with such nonlinearity there is an amplitude-frequency characteristic and resonance oscillation frequencies. In this case one can pick up the most dangerous accelerograms for the construction. The second type of nonlinearity is nonlinearity with degrading rigidity and dependence of behavior on the general loading history. The Kirikov-Amankulov model is one of such ones. Its behavior depends on the maximum displacement in the stress history. Such systems do not have gain frequency characteristic and resonance frequency. The period of oscillation of such system is increasing during the system loading, and the system eigen frequency decreases to zero at the time of collapse. In the cases under consideration, when investigating the system with MD behavior, the authors proposed new efficiency criteria. These include the work of plastic deformation forces for the first type of nonlinearity, which determines the possibility of progressive collapse or low cycle fatigue of the structure members. The period of system oscillations and the time to collapse of the structural support members are the criterion for systems with degrading rigidity. In the case of non-linear system behavior, the efficiency of MD application decreases, because the fundamental structure period is reduced because of structure damages and the MD will be rebound from the blanking regime. However, the MD using can significantly reduce the damageability of the protected object.
Johnson, Ward L; Schulz, Michal; Fritze, Holger
2014-08-01
Synthetic piezoelectric crystals in the P321 crystal class have been a focus of substantial research that is largely driven by applications in high-temperature resonant BAW and SAW sensing. Fully ordered crystals in this class, such as Ca3TaGa3Si2O14 (CTGS), have been suggested as offering the potential of electroacoustic performance that is superior to more extensively studied langasite (LGS) and langatate (LGT), which are partially disordered. In this study, the resonant frequencies, acoustic damping, and electrical conductivity of CTGS bulk acoustic resonators with Y-cut and (YXl)-30° crystal orientations and fundamental frequencies near 5 MHz are investigated at temperatures between ambient and 1100°C. (YXl)-30° resonators are found to have turnover temperatures near 200°C for the third and fifth overtones, in contrast to a monotonic decrease in resonant frequencies of Y-cut crystals with increasing temperature. The maximum temperature derivative of fractional changes in fifth-overtone frequency of (YXl)-30° CTGS is 40 × 10-6K-1 (near 1100°C), and this value is not greatly different from the temperature derivative of Y-cut CTGS frequencies over a broader range of temperatures. At ambient temperatures, the acoustic loss Q-1 of CTGS with both crystal orientations is found to be greater than the lowest values previously reported for LGS and LGT. The electrical conductivity of the CTGS specimens between 500°C and 1100°C is substantially lower than that previously reported for LGS. Corresponding to this lower conductivity, the piezoelectric/conductive contribution to Q-1 at elevated temperatures is reduced. Additional anelastic relaxation peaks observed between 100°C and 700°C are similar to those previously reported for LGS and LGT.
Miller, Patrick J O; Samarra, Filipa I P; Perthuison, Aurélie D
2007-06-01
This study investigates how particular received spectral characteristics of stereotyped calls of sexually dimorphic adult killer whales may be influenced by caller sex, orientation, and range. Calls were ascribed to individuals during natural behavior using a towed beamforming array. The fundamental frequency of both high-frequency and low-frequency components did not differ consistently by sex. The ratio of peak energy within the fundamental of the high-frequency component relative to summed peak energy in the first two low-frequency component harmonics, and the number of modulation bands off the high-frequency component, were significantly greater when whales were oriented towards the array, while range and adult sex had little effect. In contrast, the ratio of peak energy in the first versus second harmonics of the low-frequency component was greater in calls produced by adult females than adult males, while orientation and range had little effect. The dispersion of energy across harmonics has been shown to relate to body size or sex in terrestrial species, but pressure effects during diving are thought to make such a signal unreliable in diving animals. The observed spectral differences by signaler sex and orientation suggest that these types of information may be transmitted acoustically by freely diving killer whales.
Beeping and piping: characterization of two mechano-acoustic signals used by honey bees in swarming
NASA Astrophysics Data System (ADS)
Schlegel, Thomas; Visscher, P. Kirk; Seeley, Thomas D.
2012-12-01
Of the many signals used by honey bees during the process of swarming, two of them—the stop signal and the worker piping signal—are not easily distinguished for both are mechano-acoustic signals produced by scout bees who press their bodies against other bees while vibrating their wing muscles. To clarify the acoustic differences between these two signals, we recorded both signals from the same swarm and at the same time, and compared them in terms of signal duration, fundamental frequency, and frequency modulation. Stop signals and worker piping signals differ in all three variables: duration, 174 ± 64 vs. 602 ± 377 ms; fundamental frequency, 407 vs. 451 Hz; and frequency modulation, absent vs. present. While it remains unclear which differences the bees use to distinguish the two signals, it is clear that they do so for the signals have opposite effects. Stop signals cause inhibition of actively dancing scout bees whereas piping signals cause excitation of quietly resting non-scout bees.
Fundamental frequencies and resonances from eccentric and precessing binary black hole inspirals
NASA Astrophysics Data System (ADS)
Lewis, Adam G. M.; Zimmerman, Aaron; Pfeiffer, Harald P.
2017-06-01
Binary black holes which are both eccentric and undergo precession remain unexplored in numerical simulations. We present simulations of such systems which cover about 50 orbits at comparatively high mass ratios 5 and 7. The configurations correspond to the generic motion of a nonspinning body in a Kerr spacetime, and are chosen to study the transition from finite mass-ratio inspirals to point particle motion in Kerr. We develop techniques to extract analogs of the three fundamental frequencies of Kerr geodesics, compare our frequencies to those of Kerr, and show that the differences are consistent with self-force corrections entering at first order in mass ratio. This analysis also locates orbital resonances where the ratios of our frequencies take rational values. At the considered mass ratios, the binaries pass through resonances in one to two resonant cycles, and we find no discernible effects on the orbital evolution. We also compute the decay of eccentricity during the inspiral and find good agreement with the leading order post-Newtonian prediction.
Synthesis of laughter by modifying excitation characteristics.
Thati, Sathya Adithya; Kumar K, Sudheer; Yegnanarayana, B
2013-05-01
In this paper, a method to synthesize laughter by modifying the excitation source information is presented. The excitation source information is derived by extracting epoch locations and instantaneous fundamental frequency using zero frequency filtering approach. The zero frequency filtering approach is modified to capture the rapidly varying instantaneous fundamental frequency in natural laugh signals. The nature of variation of excitation features in natural laughter is examined to determine the features to be incorporated in the synthesis of a laugh signal. Features such as pitch period and strength of excitation are modified in the utterance of vowel /a/ or /i/ to generate the laughter signal. Frication is also incorporated wherever appropriate. Laugh signal is generated by varying parameters at both call level and bout level. Experiments are conducted to determine the significance of different features in the perception of laughter. Subjective evaluation is performed to determine the level of acceptance and quality of synthesis of the synthesized laughter signal for different choices of parameter values and for different input types.
Neuromuscular control of fundamental frequency and glottal posture at phonation onset
Chhetri, Dinesh K.; Neubauer, Juergen; Berry, David A.
2012-01-01
The laryngeal neuromuscular mechanisms for modulating glottal posture and fundamental frequency are of interest in understanding normal laryngeal physiology and treating vocal pathology. The intrinsic laryngeal muscles in an in vivo canine model were electrically activated in a graded fashion to investigate their effects on onset frequency, phonation onset pressure, vocal fold strain, and glottal distance at the vocal processes. Muscle activation plots for these laryngeal parameters were evaluated for the interaction of following pairs of muscle activation conditions: (1) cricothyroid (CT) versus all laryngeal adductors (TA/LCA/IA), (2) CT versus LCA/IA, (3) CT versus thyroarytenoid (TA) and, (4) TA versus LCA/IA (LCA: lateral cricoarytenoid muscle, IA: interarytenoid). Increases in onset frequency and strain were primarily affected by CT activation. Onset pressure correlated with activation of all adductors in activation condition 1, but primarily with CT activation in conditions 2 and 3. TA and CT were antagonistic for strain. LCA/IA activation primarily closed the cartilaginous glottis while TA activation closed the mid-membranous glottis. PMID:22352513
Sexual selection on male vocal fundamental frequency in humans and other anthropoids.
Puts, David A; Hill, Alexander K; Bailey, Drew H; Walker, Robert S; Rendall, Drew; Wheatley, John R; Welling, Lisa L M; Dawood, Khytam; Cárdenas, Rodrigo; Burriss, Robert P; Jablonski, Nina G; Shriver, Mark D; Weiss, Daniel; Lameira, Adriano R; Apicella, Coren L; Owren, Michael J; Barelli, Claudia; Glenn, Mary E; Ramos-Fernandez, Gabriel
2016-04-27
In many primates, including humans, the vocalizations of males and females differ dramatically, with male vocalizations and vocal anatomy often seeming to exaggerate apparent body size. These traits may be favoured by sexual selection because low-frequency male vocalizations intimidate rivals and/or attract females, but this hypothesis has not been systematically tested across primates, nor is it clear why competitors and potential mates should attend to vocalization frequencies. Here we show across anthropoids that sexual dimorphism in fundamental frequency (F0) increased during evolutionary transitions towards polygyny, and decreased during transitions towards monogamy. Surprisingly, humans exhibit greater F0 sexual dimorphism than any other ape. We also show that low-F0 vocalizations predict perceptions of men's dominance and attractiveness, and predict hormone profiles (low cortisol and high testosterone) related to immune function. These results suggest that low male F0 signals condition to competitors and mates, and evolved in male anthropoids in response to the intensity of mating competition. © 2016 The Author(s).
Cortical contributions to the auditory frequency-following response revealed by MEG
Coffey, Emily B. J.; Herholz, Sibylle C.; Chepesiuk, Alexander M. P.; Baillet, Sylvain; Zatorre, Robert J.
2016-01-01
The auditory frequency-following response (FFR) to complex periodic sounds is used to study the subcortical auditory system, and has been proposed as a biomarker for disorders that feature abnormal sound processing. Despite its value in fundamental and clinical research, the neural origins of the FFR are unclear. Using magnetoencephalography, we observe a strong, right-asymmetric contribution to the FFR from the human auditory cortex at the fundamental frequency of the stimulus, in addition to signal from cochlear nucleus, inferior colliculus and medial geniculate. This finding is highly relevant for our understanding of plasticity and pathology in the auditory system, as well as higher-level cognition such as speech and music processing. It suggests that previous interpretations of the FFR may need re-examination using methods that allow for source separation. PMID:27009409
Tunable sub-gap radiation detection with superconducting resonators
NASA Astrophysics Data System (ADS)
Dupré, O.; Benoît, A.; Calvo, M.; Catalano, A.; Goupy, J.; Hoarau, C.; Klein, T.; Le Calvez, K.; Sacépé, B.; Monfardini, A.; Levy-Bertrand, F.
2017-04-01
We have fabricated planar amorphous indium oxide superconducting resonators ({T}{{c}}˜ 2.8 K) that are sensitive to frequency-selective radiation in the range of 7-10 GHz. Those values lay far below twice the superconducting gap that is worth about 200 GHz. The photon detection consists in a shift of the fundamental resonance frequency. We show that the detected frequency can be adjusted by modulating the total length of the superconducting resonator. We attribute those observations to the excitation of higher-order resonance modes. The coupling between the fundamental lumped and the higher order distributed resonance is due to the kinetic inductance nonlinearity with current. These devices, that we have called sub-gap kinetic inductance detectors, are to be distinguished from the standard kinetic inductance detectors in which quasi-particles are generated when incident light breaks down Cooper pairs.
NASA Astrophysics Data System (ADS)
Rydberg, Anders
1990-10-01
InP TED (transferred electron device) oscillators have been experimentally investigated for frequencies between 170 and 279 GHz. It has been found that output powers of more than 7 and 0.2 mW are possible at 180 and 272 GHz using second- and third-harmonic mode operation, respectively. Conversion efficiencies of more than 13 percent and 0.3 percent between fundamental and second harmonic and fundamental and third harmonic, respectively, have been found. The conversion efficiencies are comparable to GaAs TEDs. The output powers, conversion efficiencies, and tuning ranges (more than 22 percent) are the largest reported for InP TEDs at these frequencies. The output power at third harmonic was sufficient for supplying a superconducting mixer with local oscillator power.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mokerov, V. G., E-mail: vgmokerov@yandex.ru; Kuznetsov, A. L.; Fedorov, Yu. V.
2009-04-15
The N-Al{sub 0.27}Ga{sub 0.73}N/GaN High Electron Mobility Transistors (HEMTs) with different gate lengths L{sub g} (ranging from 170 nm to 0.5 {mu}m) and gate widths W{sub s} (ranging from 100 to 1200 {mu}m) have been studied. The S parameters have been measured; these parameters have been used to determine the current-gain cutoff frequency f{sub t}, the maximum oscillation frequency f{sub max}, and the power gain MSG/MAG and Mason's coefficients were investigated in the frequency range from 10 MHz to 67 GHz in relation to the gate length and gate width. It was found that the frequencies f{sub t} and f{submore » max} attain their maximum values of f{sub t} = 48 GHz and f{sub max} = 100 GHz at L{sub g} = 170 nm and W{sub g} = 100 {mu}m. The optimum values of W{sub g} and output power P out of the basic transistors have been determined for different frequencies of operation. It has also been demonstrated that the 170 nm Al{sub 0.27}Ga{sub 0.73}N/GaN HEMT technology provides both good frequency characteristics and high breakdown voltages and is very promising for high-frequency applications (up to 40 GHz)« less
Code of Federal Regulations, 2014 CFR
2014-07-01
... filter Wet scrubber Dry scrubber followed by fabric filter and wet scrubber Maximum operating parameters: Maximum charge rate Continuous 1×hour ✔ ✔ ✔ Maximum fabric filter inlet temperature Continuous 1×minute...
Code of Federal Regulations, 2013 CFR
2013-07-01
... filter Wet scrubber Dry scrubber followed by fabric filter and wet scrubber Maximum operating parameters: Maximum charge rate Continuous 1×hour ✔ ✔ ✔ Maximum fabric filter inlet temperature Continuous 1×minute...
Ghiyas Ud Din; Imran Rafiq Chughtai; Hameed Inayat, Mansoor; Hussain Khan, Iqbal
2009-01-01
Axial mixing, holdup and slip velocity of dispersed phase which are parameters of fundamental importance in the design and operation of liquid-liquid extraction pulsed sieve plate columns have been investigated. Experiments for residence time distribution (RTD) analysis have been carried out for a range of pulsation frequency and amplitude in a liquid-liquid extraction pulsed sieve plate column with water as dispersed and kerosene as continuous phase using radiotracer technique. The column was operated in emulsion region and (99m)Tc in the form of sodium pertechnetate eluted from a (99)Mo/(99m)Tc generator was used to trace the dispersed phase. Axial dispersed plug flow model with open-open boundary condition and two points measurement method was used to simulate the hydrodynamics of dispersed phase. It has been observed that the axial mixing and holdup of dispersed phase increases with increase in pulsation frequency and amplitude until a maximum value is achieved while slip velocity decreases with increase in pulsation frequency and amplitude until it approaches a minimum value. Short lived and low energy radiotracer (99m)Tc in the form of sodium pertechnetate was found to be a good water tracer to study the hydrodynamics of a liquid-liquid extraction pulsed sieve plate column operating with two immiscible liquids, water and kerosene. Axial dispersed plug flow model with open-open boundary condition was found to be a suitable model to describe the hydrodynamics of dispersed phase in the pulsed sieve plate extraction column.
Soft context clustering for F0 modeling in HMM-based speech synthesis
NASA Astrophysics Data System (ADS)
Khorram, Soheil; Sameti, Hossein; King, Simon
2015-12-01
This paper proposes the use of a new binary decision tree, which we call a soft decision tree, to improve generalization performance compared to the conventional `hard' decision tree method that is used to cluster context-dependent model parameters in statistical parametric speech synthesis. We apply the method to improve the modeling of fundamental frequency, which is an important factor in synthesizing natural-sounding high-quality speech. Conventionally, hard decision tree-clustered hidden Markov models (HMMs) are used, in which each model parameter is assigned to a single leaf node. However, this `divide-and-conquer' approach leads to data sparsity, with the consequence that it suffers from poor generalization, meaning that it is unable to accurately predict parameters for models of unseen contexts: the hard decision tree is a weak function approximator. To alleviate this, we propose the soft decision tree, which is a binary decision tree with soft decisions at the internal nodes. In this soft clustering method, internal nodes select both their children with certain membership degrees; therefore, each node can be viewed as a fuzzy set with a context-dependent membership function. The soft decision tree improves model generalization and provides a superior function approximator because it is able to assign each context to several overlapped leaves. In order to use such a soft decision tree to predict the parameters of the HMM output probability distribution, we derive the smoothest (maximum entropy) distribution which captures all partial first-order moments and a global second-order moment of the training samples. Employing such a soft decision tree architecture with maximum entropy distributions, a novel speech synthesis system is trained using maximum likelihood (ML) parameter re-estimation and synthesis is achieved via maximum output probability parameter generation. In addition, a soft decision tree construction algorithm optimizing a log-likelihood measure is developed. Both subjective and objective evaluations were conducted and indicate a considerable improvement over the conventional method.
NASA Astrophysics Data System (ADS)
Ambekar Ramachandra Rao, Raghu; Mehta, Monal R.; Toussaint, Kimani C., Jr.
2010-02-01
We demonstrate the use of Fourier transform-second-harmonic generation (FT-SHG) imaging of collagen fibers as a means of performing quantitative analysis of obtained images of selected spatial regions in porcine trachea, ear, and cornea. Two quantitative markers, preferred orientation and maximum spatial frequency are proposed for differentiating structural information between various spatial regions of interest in the specimens. The ear shows consistent maximum spatial frequency and orientation as also observed in its real-space image. However, there are observable changes in the orientation and minimum feature size of fibers in the trachea indicating a more random organization. Finally, the analysis is applied to a 3D image stack of the cornea. It is shown that the standard deviation of the orientation is sensitive to the randomness in fiber orientation. Regions with variations in the maximum spatial frequency, but with relatively constant orientation, suggest that maximum spatial frequency is useful as an independent quantitative marker. We emphasize that FT-SHG is a simple, yet powerful, tool for extracting information from images that is not obvious in real space. This technique can be used as a quantitative biomarker to assess the structure of collagen fibers that may change due to damage from disease or physical injury.
External morphology and calling song characteristics in Tibicen plebejus (Hemiptera: Cicadidae).
Mehdipour, Maedeh; Sendi, Jalal Jalali; Zamanian, Hossein
2015-02-01
Tibicen plebejus is the largest cicada native to the ecosystem in northern Iran. The male cicada produces a loud calling song for attracting females from a long distance. It is presumed that the female selects a mate based on a combination of passive and active mechanisms, but it is not known if she selects for size, nor if the male's size correlates with any characteristic of the advertisement call. In this study, we report the relationship between calling song features and morphological characters in the male of T. plebejus. Research was conducted in northern Iran during the summer of 2010. Seventeen males were collected and their calling songs were recorded in a natural environment. Two morphological characters were measured: length and weight. Maximum, minimum and average of values of 10 key acoustic variables of the calling song were analyzed: phrase duration, phrase part 1, phrase part 2, number of phrases per minute, echeme duration, echeme period, interecheme interval, number of echeme per second, echeme/intereheme ratio, and dominant frequency. The data were tested for the level of association between morphology and acoustic variables using simple linear regression. In conclusion, in terms of song structure, three significant positive correlations existed between length and (1) mean echeme duration, (2) mean echeme/interecheme ratio, (3) maximum echeme/interecheme ratio. We found out also four significant negative correlations between both length and weight with (1) minimum interecheme intervals, (2) mean dominant frequency, (3) minimum dominant frequency, (4) maximum dominant frequency, and between weight and (1) minimum interecheme intervals, (2) mean dominant frequency, (3) minimum dominant frequency, (4) maximum dominant frequency. It can be found that larger males of T. plebejus produce songs of lower frequency and are less silent between echemes. Copyright © 2014 Académie des sciences. Published by Elsevier SAS. All rights reserved.
Harmonic mode-locking using the double interval technique in quantum dot lasers.
Li, Yan; Chiragh, Furqan L; Xin, Yong-Chun; Lin, Chang-Yi; Kim, Junghoon; Christodoulou, Christos G; Lester, Luke F
2010-07-05
Passive harmonic mode-locking in a quantum dot laser is realized using the double interval technique, which uses two separate absorbers to stimulate a specific higher-order repetition rate compared to the fundamental. Operating alone these absorbers would otherwise reinforce lower harmonic frequencies, but by operating together they produce the harmonic corresponding to their least common multiple. Mode-locking at a nominal 60 GHz repetition rate, which is the 10(th) harmonic of the fundamental frequency of the device, is achieved unambiguously despite the constraint of a uniformly-segmented, multi-section device layout. The diversity of repetition rates available with this method is also discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yashchuk, Valeriy V; Conley, Raymond; Anderson, Erik H.
We discuss the results of SEM and TEM measurements with the BPRML test samples fabricated from a BPRML (WSi2/Si with fundamental layer thickness of 3 nm) with a Dual Beam FIB (focused ion beam)/SEM technique. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize x-raymore » microscopes. Corresponding work with x-ray microscopes is in progress.« less
Testing Fundamental Properties of Space with the Fermilab Holometer
Kamai, Brittany
2017-06-01
Precision length measurements provide valuable insights about the fundamental properties of space-time. The Holometer is a research program to both experimentally probe signatures of the Planck scale and to extend the accessible frequency range from kHz up to MHz for gravitational wave searches. The instrument consists of separate yet identical 39-meter Michelson interferometers operated at Fermi National Accelerator Laboratory, which can reach length sensitivities better thanmore » $${10}^{-20}\\mathrm{m/}\\sqrt{\\mathrm{Hz}}$$ within the 1-10 MHz frequency range. Lastly, the Holometer is fully operational with 130 of hours of science quality data obtained during the first observational campaign.« less
Interspecific variation of warning calls in piranhas: a comparative analysis.
Mélotte, Geoffrey; Vigouroux, Régis; Michel, Christian; Parmentier, Eric
2016-10-26
Fish sounds are known to be species-specific, possessing unique temporal and spectral features. We have recorded and compared sounds in eight piranha species to evaluate the potential role of acoustic communication as a driving force in clade diversification. All piranha species showed the same kind of sound-producing mechanism: sonic muscles originate on vertebrae and attach to a tendon surrounding the bladder ventrally. Contractions of the sound-producing muscles force swimbladder vibration and dictate the fundamental frequency. It results the calling features of the eight piranha species logically share many common characteristics. In all the species, the calls are harmonic sounds composed of multiple continuous cycles. However, the sounds of Serrasalmus elongatus (higher number of cycles and high fundamental frequency) and S. manueli (long cycle periods and low fundamental frequency) are clearly distinguishable from the other species. The sonic mechanism being largely conserved throughout piranha evolution, acoustic communication can hardly be considered as the main driving force in the diversification process. However, sounds of some species are clearly distinguishable despite the short space for variations supporting the need for specific communication. Behavioural studies are needed to clearly understand the eventual role of the calls during spawning events.
HUMAN SPEECH: A RESTRICTED USE OF THE MAMMALIAN LARYNX
Titze, Ingo R.
2016-01-01
Purpose Speech has been hailed as unique to human evolution. While the inventory of distinct sounds producible with vocal tract articulators is a great advantage in human oral communication, it is argued here that the larynx as a sound source in speech is limited in its range and capability because a low fundamental frequency is ideal for phonemic intelligibility and source-filter independence. Method Four existing data sets were combined to make an argument regarding exclusive use of the larynx for speech: (1) range of fundamental frequency, (2) laryngeal muscle activation, (3) vocal fold length in relation to sarcomere length of the major laryngeal muscles, and (4) vocal fold morphological development. Results Limited data support the notion that speech tends to produce a contracture of the larynx. The morphological design of the human vocal folds, like that of primates and other mammals, is optimized for vocal communication over distances for which higher fundamental frequency, higher intensity, and fewer unvoiced segments are utilized than in conversational speech. Conclusion The positive message is that raising one’s voice to call, shout, or sing, or executing pitch glides to stretch the vocal folds, can counteract this trend toward a contracted state. PMID:27397113
Spectral analysis of unsteady surface pressure on a pusher propeller
NASA Technical Reports Server (NTRS)
Farokhi, Saeed
1992-01-01
A propeller of an advanced turboprop testbed aircraft in pusher configuration is instrumented with 22 miniature blade-mounted transducers (BMTs) at two radii. Upstream pylon wake interaction with the propeller is the source of a one-per-cycle excitation for the blades in flight. The time history of fluctuating pressure signals over 26 flight conditions is statistically analyzed in the frequency domain. The rms amplitude of fluctuating pressure signals measured by suction surface BMTs indicates a very strong presence of the fundamental frequency over most of the upper surface. The pylon wake pressure signature on the propeller trailing edge, i.e., x/c not less than 0.80, shows predominantly random turbulence; hence, the amplitude of the fundamental frequency wave is fairly small. The resurgence of a large amplitude fundamental harmonic with coherent pylon wake signature further downstream, say at 90 percent chord, is unexpected behavior. The appearance of a dominating second propeller shaft order in the spectra of the rms pressure in transonic flight conditions identifies the presence of a two-per-cycle excitation source in the azimuthal direction. This is due to the presence of a shock wave, as evidenced by the pressure-time history plots.
Zhang, Zhaoyan
2016-01-01
The goal of this study is to better understand the cause-effect relation between vocal fold physiology and the resulting vibration pattern and voice acoustics. Using a three-dimensional continuum model of phonation, the effects of changes in vocal fold stiffness, medial surface thickness in the vertical direction, resting glottal opening, and subglottal pressure on vocal fold vibration and different acoustic measures are investigated. The results show that the medial surface thickness has dominant effects on the vertical phase difference between the upper and lower margins of the medial surface, closed quotient, H1-H2, and higher-order harmonics excitation. The main effects of vocal fold approximation or decreasing resting glottal opening are to lower the phonation threshold pressure, reduce noise production, and increase the fundamental frequency. Increasing subglottal pressure is primarily responsible for vocal intensity increase but also leads to significant increase in noise production and an increased fundamental frequency. Increasing AP stiffness significantly increases the fundamental frequency and slightly reduces noise production. The interaction among vocal fold thickness, stiffness, approximation, and subglottal pressure in the control of F0, vocal intensity, and voice quality is discussed. PMID:27106298
Interspecific variation of warning calls in piranhas: a comparative analysis
Mélotte, Geoffrey; Vigouroux, Régis; Michel, Christian; Parmentier, Eric
2016-01-01
Fish sounds are known to be species-specific, possessing unique temporal and spectral features. We have recorded and compared sounds in eight piranha species to evaluate the potential role of acoustic communication as a driving force in clade diversification. All piranha species showed the same kind of sound-producing mechanism: sonic muscles originate on vertebrae and attach to a tendon surrounding the bladder ventrally. Contractions of the sound-producing muscles force swimbladder vibration and dictate the fundamental frequency. It results the calling features of the eight piranha species logically share many common characteristics. In all the species, the calls are harmonic sounds composed of multiple continuous cycles. However, the sounds of Serrasalmus elongatus (higher number of cycles and high fundamental frequency) and S. manueli (long cycle periods and low fundamental frequency) are clearly distinguishable from the other species. The sonic mechanism being largely conserved throughout piranha evolution, acoustic communication can hardly be considered as the main driving force in the diversification process. However, sounds of some species are clearly distinguishable despite the short space for variations supporting the need for specific communication. Behavioural studies are needed to clearly understand the eventual role of the calls during spawning events. PMID:27782184
NASA Astrophysics Data System (ADS)
Sisakun, Siphan
2000-12-01
The purpose of this study is to explore the ability of four acoustic parameters, mean fundamental frequency, jitter, shimmer, and harmonics-to-noise ratio, to detect vocal fatigue in student singers. The participants are 15 voice students, who perform two distinct tasks, data collection task and vocal fatiguing task. The data collection task includes the sustained vowel /a/, reading a standard passage, and self-rate on a vocal fatigue form. The vocal fatiguing task is the vocal practice of musical scores for a total of 45 minutes. The four acoustic parameters are extracted using the software EZVoicePlus. The data analyses are performed to answer eight research questions. The first four questions relate to correlations of the self-rating scale and each of the four parameters. The next four research questions relate to differences in the parameters over time using one-factor repeated measures analysis of variance (ANOVA). The result yields a proposed acoustic profile of vocal fatigue in student singers. This profile is characterized by increased fundamental frequency; slightly decreased jitter; slightly decreased shimmer; and slightly increased harmonics-to-noise ratio. The proposed profile requires further investigation.
Optimal behavior of viscoelastic flow at resonant frequencies.
Lambert, A A; Ibáñez, G; Cuevas, S; del Río, J A
2004-11-01
The global entropy generation rate in the zero-mean oscillatory flow of a Maxwell fluid in a pipe is analyzed with the aim of determining its behavior at resonant flow conditions. This quantity is calculated explicitly using the analytic expression for the velocity field and assuming isothermal conditions. The global entropy generation rate shows well-defined peaks at the resonant frequencies where the flow displays maximum velocities. It was found that resonant frequencies can be considered optimal in the sense that they maximize the power transmitted to the pulsating flow at the expense of maximum dissipation.
Design optimization of MR-compatible rotating anode x-ray tubes for stable operation
Shin, Mihye; Lillaney, Prasheel; Hinshaw, Waldo; Fahrig, Rebecca
2013-01-01
Purpose: Hybrid x-ray/MR systems can enhance the diagnosis and treatment of endovascular, cardiac, and neurologic disorders by using the complementary advantages of both modalities for image guidance during interventional procedures. Conventional rotating anode x-ray tubes fail near an MR imaging system, since MR fringe fields create eddy currents in the metal rotor which cause a reduction in the rotation speed of the x-ray tube motor. A new x-ray tube motor prototype has been designed and built to be operated close to a magnet. To ensure the stability and safety of the motor operation, dynamic characteristics must be analyzed to identify possible modes of mechanical failure. In this study a 3D finite element method (FEM) model was developed in order to explore possible modifications, and to optimize the motor design. The FEM provides a valuable tool that permits testing and evaluation using numerical simulation instead of building multiple prototypes. Methods: Two experimental approaches were used to measure resonance characteristics: the first obtained the angular speed curves of the x-ray tube motor employing an angle encoder; the second measured the power spectrum using a spectrum analyzer, in which the large amplitude of peaks indicates large vibrations. An estimate of the bearing stiffness is required to generate an accurate FEM model of motor operation. This stiffness depends on both the bearing geometry and adjacent structures (e.g., the number of balls, clearances, preload, etc.) in an assembly, and is therefore unknown. This parameter was set by matching the FEM results to measurements carried out with the anode attached to the motor, and verified by comparing FEM predictions and measurements with the anode removed. The validated FEM model was then used to sweep through design parameters [bearing stiffness (1×105–5×107 N/m), shaft diameter (0.372–0.625 in.), rotor diameter (2.4–2.9 in.), and total length of motor (5.66–7.36 in.)] to increase the fundamental frequency past the operating range at 50 Hz. Results: The first large vibration during the prototype motor operation was obtained at 21.64±0.68 Hz in the power spectrum. An abrupt decrease in acceleration occurred at 21.5 Hz due to struggling against the resonance vibrations. A bearing stiffness of 1.2×105 N/m in the FEM simulation was used to obtain a critical speed of 21.4 Hz providing 1.1% error. This bearing stiffness value and the 3D model were then confirmed by the experiments with the anode removed, demonstrating an agreement within 6.4% between simulation results and measurements. A calculated first critical frequency (fundamental frequency) of 68.5 Hz was obtained by increasing the bearing stiffness to 1×107 N/m and increasing the shaft diameter by 68.0%. Reducing the number of bearings in the design permits decreasing the total length of the motor by 1.7 in., and results in a fundamental frequency of 68.3 Hz in concert with additional changes (shaft diameter of 0.625 in., rotor diameter of 2.4 in., and bearing stiffness of 1×106 N/m). Conclusions: An FEM model of the x-ray tube motor has been implemented and experimentally validated. A fundamental frequency above the operational rotation speed can be achieved through modification of multiple design parameters, which allows the motor to operate stably and safely in the MR environment during the repeated acceleration/deceleration cycles required for an interventional procedure. The validated 3D FEM model can now be used to investigate trade-offs between generated torque, maximum speed, and motor inertia to further optimize motor design. PMID:24320446
Finite-Element Modelling of the Acoustic Input Admittance of the Newborn Ear Canal and Middle Ear.
Motallebzadeh, Hamid; Maftoon, Nima; Pitaro, Jacob; Funnell, W Robert J; Daniel, Sam J
2017-02-01
Admittance measurement is a promising tool for evaluating the status of the middle ear in newborns. However, the newborn ear is anatomically very different from the adult one, and the acoustic input admittance is different than in adults. To aid in understanding the differences, a finite-element model of the newborn ear canal and middle ear was developed and its behaviour was studied for frequencies up to 2000 Hz. Material properties were taken from previous measurements and estimates. The simulation results were within the range of clinical admittance measurements made in newborns. Sensitivity analyses of the material properties show that in the canal model, the maximum admittance and the frequency at which that maximum admittance occurs are affected mainly by the stiffness parameter; in the middle-ear model, the damping is as important as the stiffness in influencing the maximum admittance magnitude but its effect on the corresponding frequency is negligible. Scaling up the geometries increases the admittance magnitude and shifts the resonances to lower frequencies. The results suggest that admittance measurements can provide more information about the condition of the middle ear when made at multiple frequencies around its resonance.
Piai, Vitória; Roelofs, Ardi; Maris, Eric
2014-01-01
Two fundamental factors affecting the speed of spoken word production are lexical frequency and sentential constraint, but little is known about their timing and electrophysiological basis. In the present study, we investigated event-related potentials (ERPs) and oscillatory brain responses induced by these factors, using a task in which participants named pictures after reading sentences. Sentence contexts were either constraining or nonconstraining towards the final word, which was presented as a picture. Picture names varied in their frequency of occurrence in the language. Naming latencies and electrophysiological responses were examined as a function of context and lexical frequency. Lexical frequency is an index of our cumulative learning experience with words, so lexical-frequency effects most likely reflect access to memory representations for words. Pictures were named faster with constraining than nonconstraining contexts. Associated with this effect, starting around 400 ms pre-picture presentation, oscillatory power between 8 and 30 Hz was lower for constraining relative to nonconstraining contexts. Furthermore, pictures were named faster with high-frequency than low-frequency names, but only for nonconstraining contexts, suggesting differential ease of memory access as a function of sentential context. Associated with the lexical-frequency effect, starting around 500 ms pre-picture presentation, oscillatory power between 4 and 10 Hz was higher for high-frequency than for low-frequency names, but only for constraining contexts. Our results characterise electrophysiological responses associated with lexical frequency and sentential constraint in spoken word production, and point to new avenues for studying these fundamental factors in language production. © 2013 Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Birman, Victor; Byrd, Larry W.
2008-02-01
The interest to functionally graded materials (FGM) and structures has been generated by their potential advantages, including enhanced thermal properties, reduced or eliminated delamination concerns, a potential for an improved stress distribution, etc. Various aspects of the processing, design, micromechanics and analysis of FGM have been outlined in a number of reviews, mentioned here are [1-3]. In particular, functionally graded panels may be advantageous compared to their conventional counterparts in numerous applications. However, a typical FGM panel is asymmetric about its middle plane resulting in lower buckling loads and fundamental frequencies as well as higher stresses and deformations than the counterpart with a symmetric distribution of the same constituents. The reduced stiffness of FGM panels can be compensated by reinforcing them with stringers. For example, metallic stringers at the metal-rich surface of a FGM ceramic-metal panel may provide an efficient solution enabling a designer to increase both buckling loads as well as natural frequencies. The list of studies on optimization of FGM is extensive as could be anticipated for such tailored structural elements. For example, recent papers by Batra and his collaborators present optimization of the natural frequencies of a FGM plate through material grading [4] and through the graded fiber orientation [5]. The present paper is concerned with an optimum design of the system of stringers for a specified FGM panel. The task is to design the lightest system of stringers enabling the panel to achieve prescribed buckling loads or fundamental frequency.
Hadamard-Encoded Multipulses for Contrast-Enhanced Ultrasound Imaging.
Gong, Ping; Song, Pengfei; Chen, Shigao
2017-11-01
The development of contrast-enhanced ultrasound (CEUS) imaging offers great opportunities for new ultrasound clinical applications such as myocardial perfusion imaging and abdominal lesion characterization. In CEUS imaging, the contrast agents (i.e., microbubbles) are utilized to improve the contrast between blood and tissue based on their high nonlinearity under low ultrasound pressure. In this paper, we propose a new CEUS pulse sequence by combining Hadamard-encoded multipulses (HEM) with fundamental frequency bandpass filter (i.e., filter centered on transmit frequency). HEM consecutively emits multipulses encoded by a second-order Hadamard matrix in each of the two transmission events (i.e., pulse-echo events), as opposed to conventional CEUS methods which emit individual pulses in two separate transmission events (i.e., pulse inversion (PI), amplitude modulation (AM), and PIAM). In HEM imaging, the microbubble responses can be improved by the longer transmit pulse, and the tissue harmonics can be suppressed by the fundamental frequency filter, leading to significantly improved contrast-to-tissue ratio (CTR) and signal-to-noise ratio (SNR). In addition, the fast polarity change between consecutive coded pulse emissions excites strong nonlinear microbubble echoes, further enhancing the CEUS image quality. The spatial resolution of HEM image is compromised as compared to other microbubble imaging methods due to the longer transmit pulses and the lower imaging frequency (i.e., fundamental frequency). However, the resolution loss was shown to be negligible and could be offset by the significantly enhanced CTR, SNR, and penetration depth. These properties of HEM can potentially facilitate robust CEUS imaging for many clinical applications, especially for deep abdominal organs and heart.
47 CFR 74.637 - Emissions and emission limitations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... vestigial sideband AM video: On any frequency removed from the center frequency of the authorized band by... communications. Frequency Band (MHz) Maximum authorized bandwidth (MHz) 1,990 to 2,110 18 6,425 to 6,525 25 6,875...
47 CFR 74.637 - Emissions and emission limitations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... vestigial sideband AM video: On any frequency removed from the center frequency of the authorized band by... communications. Frequency Band (MHz) Maximum authorized bandwidth (MHz) 1,990 to 2,110 18 6,425 to 6,525 25 6,875...
47 CFR 74.637 - Emissions and emission limitations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... vestigial sideband AM video: On any frequency removed from the center frequency of the authorized band by... communications. Frequency Band (MHz) Maximum authorized bandwidth (MHz) 1,990 to 2,110 18 6,425 to 6,525 25 6,875...
47 CFR 74.637 - Emissions and emission limitations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... vestigial sideband AM video: On any frequency removed from the center frequency of the authorized band by... communications. Frequency Band (MHz) Maximum authorized bandwidth (MHz) 1,990 to 2,110 18 6,425 to 6,525 25 6,875...
47 CFR 74.637 - Emissions and emission limitations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... vestigial sideband AM video: On any frequency removed from the center frequency of the authorized band by... communications. Frequency Band (MHz) Maximum authorized bandwidth (MHz) 1,990 to 2,110 18 6,425 to 6,525 25 6,875...
Spatial-frequency spectrum of patterns changes the visibility of spatial-phase differences
NASA Technical Reports Server (NTRS)
Lawton, T. B.
1985-01-01
It is shown that spatial-frequency components over a 4-octave range affected the visibility of spatial-phase differences. Contrast thresholds were measured for discrimination between two (+45- and -45-deg) spatial phases of a sinusoidal test grating added to a background grating. The background could contain one or several sinusoidal components, all in 0-deg phase. Phase differences between the test and the background were visible at lower contrasts when test and background frequencies were harmonically related than when they were not, when test and background frequencies were within 1 octave than when they were farther apart, when the fundamental frequency of the background was low than when it was high, and for some discriminations more than for others, after practice. The visibility of phase differences was not affected by additional components in the background if the fundamental and difference frequencies of the background remained unchanged. Observers' reports of their strategies gave information about the types of attentive processing that were used to discriminate phase differences. Attentive processing facilitated phase discrimination for multifrequency gratings spanning a much wider range of spatial frequencies than would be possible by using only local preattentive processing. These results were consistent with the visibility of phase differences being processed by some combination of even- and odd-symmetric simple cells tuned to a wide range of different spatial frequencies.
47 CFR 15.207 - Conducted limits.
Code of Federal Regulations, 2010 CFR
2010-10-01
... apply to carrier current systems operating as intentional radiators on frequencies below 30 MHz. In lieu... current system containing their fundamental emission within the frequency band 535-1705 kHz and intended.../50 ohms LISN. (3) Carrier current systems operating below 30 MHz are also subject to the radiated...
Frequency dependence of the maximum operating temperature for quantum-cascade lasers up to 5.4 THz
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wienold, M.; Humboldt Universität zu Berlin, Institut für Physik, Newtonstr. 15, 12489 Berlin; Deutsches Zentrum für Luft und Raumfahrt, Rutherfordstr. 2, 12489 Berlin
2015-11-16
We report on the observation of an approximately linear reduction in the maximum operating temperature with an increasing emission frequency for terahertz quantum-cascade lasers between 4.2 and 5.4 THz. These lasers are based on the same design type, but vary in period length and barrier height for the cascade structure. The sample emitting at the highest frequency around 5.4 THz can be operated in pulsed mode up to 56 K. We identify an additional relaxation channel for electrons by longitudinal optical phonon scattering from the upper to the lower laser level and increasing optical losses toward higher frequencies as major processes,more » leading to the observed temperature behavior.« less
NASA Astrophysics Data System (ADS)
Kojima, Yohei; Takeda, Kazuaki; Adachi, Fumiyuki
Frequency-domain equalization (FDE) based on the minimum mean square error (MMSE) criterion can provide better downlink bit error rate (BER) performance of direct sequence code division multiple access (DS-CDMA) than the conventional rake combining in a frequency-selective fading channel. FDE requires accurate channel estimation. In this paper, we propose a new 2-step maximum likelihood channel estimation (MLCE) for DS-CDMA with FDE in a very slow frequency-selective fading environment. The 1st step uses the conventional pilot-assisted MMSE-CE and the 2nd step carries out the MLCE using decision feedback from the 1st step. The BER performance improvement achieved by 2-step MLCE over pilot assisted MMSE-CE is confirmed by computer simulation.
Enhanced vasomotion of cerebral arterioles in spontaneously hypertensive rats
NASA Technical Reports Server (NTRS)
Lefer, D. J.; Lynch, C. D.; Lapinski, K. C.; Hutchins, P. M.
1990-01-01
Intrinsic rhythmic changes in the diameter of pial cerebral arterioles (30-70 microns) in anesthetized normotensive and hypertensive rats were assessed in vivo to determine if any significant differences exist between the two strains. All diameter measurements were analyzed using a traditional graphic analysis technique and a new frequency spectrum analysis technique known as the Prony Spectral Line Estimator. Graphic analysis of the data revealed that spontaneously hypertensive rats (SHR) possess a significantly greater fundamental frequency (5.57 +/- 0.28 cycles/min) of vasomotion compared to the control Wistar-Kyoto normotensive rats (WKY) (1.95 +/- 0.37 cycles/min). Furthermore, the SHR cerebral arterioles exhibited a significantly greater amplitude of vasomotion (10.07 +/- 0.70 microns) when compared to the WKY cerebral arterioles of the same diameter (8.10 +/- 0.70 microns). Diameter measurements processed with the Prony technique revealed that the fundamental frequency of vasomotion in SHR cerebral arterioles (6.14 +/- 0.39 cycles/min) was also significantly greater than that of the WKY cerebral arterioles (2.99 +/- 0.42 cycles/min). The mean amplitudes of vasomotion in the SHR and WKY strains obtained by the Prony analysis were found not to be statistically significant in contrast to the graphic analysis of the vasomotion amplitude of the arterioles. In addition, the Prony system was able to consistently uncover a very low frequency of vasomotion in both strains of rats that was typically less than 1 cycle/min and was not significantly different between the two strains. The amplitude of this slow frequency was also not significantly different between the two strains. The amplitude of the slow frequency of vasomotion (less than 1 cycle/min) was not different from the amplitude of the higher frequency (2-6 cycles/min) vasomotion by Prony or graphic analysis. These data suggest that a fundamental intrinsic defect exists in the spontaneously hypertensive rat that may contribute to the pathogenesis of hypertension in these animals.
NASA Astrophysics Data System (ADS)
Alcock, C.; Allsman, R.; Alves, D. R.; Axelrod, T.; Becker, A.; Bennett, D.; Clement, C.; Cook, K. H.; Drake, A.; Freeman, K.; Geha, M.; Griest, K.; Kovács, G.; Kurtz, D. W.; Lehner, M.; Marshall, S.; Minniti, D.; Nelson, C.; Peterson, B.; Popowski, P.; Pratt, M.; Quinn, P.; Rodgers, A.; Rowe, J.; Stubbs, C.; Sutherland, W.; Tomaney, A.; Vandehei, T.; Welch, D. L.
2000-10-01
More than 1300 variables classified provisionally as first-overtone RR Lyrae pulsators in the MACHO variable-star database of the Large Magellanic Cloud (LMC) have been subjected to standard frequency analysis. Based on the remnant power in the prewhitened spectra, we found 70% of the total population to be monoperiodic. The remaining 30% (411 stars) are classified as one of nine types according to their frequency spectra. Several types of RR Lyrae pulsational behavior are clearly identified here for the first time. Together with the earlier discovered double-mode (fundamental and first-overtone) variables, this study increased the number of known double-mode stars in the LMC to 181. During the total 6.5 yr time span of the data, 10% of the stars showed strong period changes. The size, and in general also the patterns of the period changes, exclude a simple evolutionary explanation. We also discovered two additional types of multifrequency pulsators with low occurrence rates of 2% for each. In the first type, there remains one closely spaced component after prewhitening by the main pulsation frequency. In the second type, the number of remnant components is two; they are also closely spaced, and are symmetric in their frequency spacing relative to the central component. This latter type of variables are associated with their relatives among the fundamental pulsators, known as Blazhko variables. Their high frequency (~20%) among the fundamental-mode variables versus the low occurrence rate of their first-overtone counterparts makes it more difficult to explain the Blazhko phenomenon by any theory depending mainly on the role of aspect angle or magnetic field. None of the current theoretical models are able to explain the observed close frequency components without invoking nonradial pulsation components in these stars.
Nie, Weijie; Jia, Yuechen; Vázquez de Aldana, Javier R.; Chen, Feng
2016-01-01
Integrated photonic devices with beam splitting function are intriguing for a broad range of photonic applications. Through optical-lattice-like cladding waveguide structures fabricated by direct femtosecond laser writing, the light propagation can be engineered via the track-confined refractive index profiles, achieving tailored output beam distributions. In this work, we report on the fabrication of 3D laser-written optical-lattice-like structures in a nonlinear KTP crystal to implement 1 × 4 beam splitting. Second harmonic generation (SHG) of green light through these nonlinear waveguide beam splitter structures provides the capability for the compact visible laser emitting devices. With Type II phase matching of the fundamental wavelength (@ 1064 nm) to second harmonic waves (@ 532 nm), the frequency doubling has been achieved through this three-dimensional beam splitter. Under 1064-nm continuous-wave fundamental-wavelength pump beam, guided-wave SHG at 532 nm are measured with the maximum power of 0.65 mW and 0.48 mW for waveguide splitters (0.67 mW and 0.51 mW for corresponding straight channel waveguides), corresponding to a SH conversion efficiency of approximately ~14.3%/W and 13.9%/W (11.2%/W, 11.3%/W for corresponding straight channel waveguides), respectively. This work paves a way to fabricate compact integrated nonlinear photonic devices in a single chip with beam dividing functions. PMID:26924255
Nie, Weijie; Jia, Yuechen; Vázquez de Aldana, Javier R; Chen, Feng
2016-02-29
Integrated photonic devices with beam splitting function are intriguing for a broad range of photonic applications. Through optical-lattice-like cladding waveguide structures fabricated by direct femtosecond laser writing, the light propagation can be engineered via the track-confined refractive index profiles, achieving tailored output beam distributions. In this work, we report on the fabrication of 3D laser-written optical-lattice-like structures in a nonlinear KTP crystal to implement 1 × 4 beam splitting. Second harmonic generation (SHG) of green light through these nonlinear waveguide beam splitter structures provides the capability for the compact visible laser emitting devices. With Type II phase matching of the fundamental wavelength (@ 1064 nm) to second harmonic waves (@ 532 nm), the frequency doubling has been achieved through this three-dimensional beam splitter. Under 1064-nm continuous-wave fundamental-wavelength pump beam, guided-wave SHG at 532 nm are measured with the maximum power of 0.65 mW and 0.48 mW for waveguide splitters (0.67 mW and 0.51 mW for corresponding straight channel waveguides), corresponding to a SH conversion efficiency of approximately ~14.3%/W and 13.9%/W (11.2%/W, 11.3%/W for corresponding straight channel waveguides), respectively. This work paves a way to fabricate compact integrated nonlinear photonic devices in a single chip with beam dividing functions.
Tuning quadratic nonlinear photonic crystal fibers for zero group-velocity mismatch.
Bache, Morten; Nielsen, Hanne; Laegsgaard, Jesper; Bang, Ole
2006-06-01
We consider an index-guiding silica photonic crystal fiber with a triangular hole pattern and a periodically poled quadratic nonlinearity. By tuning the pitch and the relative hole size, second-harmonic generation with zero group-velocity mismatch is found for any fundamental wavelength above 780 nm. The nonlinear strength is optimized when the fundamental has maximum confinement in the core. The conversion bandwidth allows for femtosecond-pulse conversion, and 4%-180%W(-1)cm(-2) relative efficiencies were found.
Bhalla, Amneet Pal Singh; Griffith, Boyce E; Patankar, Neelesh A
2013-01-01
A fundamental issue in locomotion is to understand how muscle forcing produces apparently complex deformation kinematics leading to movement of animals like undulatory swimmers. The question of whether complicated muscle forcing is required to create the observed deformation kinematics is central to the understanding of how animals control movement. In this work, a forced damped oscillation framework is applied to a chain-link model for undulatory swimming to understand how forcing leads to deformation and movement. A unified understanding of swimming, caused by muscle contractions ("active" swimming) or by forces imparted by the surrounding fluid ("passive" swimming), is obtained. We show that the forcing triggers the first few deformation modes of the body, which in turn cause the translational motion. We show that relatively simple forcing patterns can trigger seemingly complex deformation kinematics that lead to movement. For given muscle activation, the forcing frequency relative to the natural frequency of the damped oscillator is important for the emergent deformation characteristics of the body. The proposed approach also leads to a qualitative understanding of optimal deformation kinematics for fast swimming. These results, based on a chain-link model of swimming, are confirmed by fully resolved computational fluid dynamics (CFD) simulations. Prior results from the literature on the optimal value of stiffness for maximum speed are explained.
Bhalla, Amneet Pal Singh; Griffith, Boyce E.; Patankar, Neelesh A.
2013-01-01
A fundamental issue in locomotion is to understand how muscle forcing produces apparently complex deformation kinematics leading to movement of animals like undulatory swimmers. The question of whether complicated muscle forcing is required to create the observed deformation kinematics is central to the understanding of how animals control movement. In this work, a forced damped oscillation framework is applied to a chain-link model for undulatory swimming to understand how forcing leads to deformation and movement. A unified understanding of swimming, caused by muscle contractions (“active” swimming) or by forces imparted by the surrounding fluid (“passive” swimming), is obtained. We show that the forcing triggers the first few deformation modes of the body, which in turn cause the translational motion. We show that relatively simple forcing patterns can trigger seemingly complex deformation kinematics that lead to movement. For given muscle activation, the forcing frequency relative to the natural frequency of the damped oscillator is important for the emergent deformation characteristics of the body. The proposed approach also leads to a qualitative understanding of optimal deformation kinematics for fast swimming. These results, based on a chain-link model of swimming, are confirmed by fully resolved computational fluid dynamics (CFD) simulations. Prior results from the literature on the optimal value of stiffness for maximum speed are explained. PMID:23785272
Deficits in the pitch sensitivity of cochlear-implanted children speaking English or Mandarin
Deroche, Mickael L. D.; Lu, Hui-Ping; Limb, Charles J.; Lin, Yung-Song; Chatterjee, Monita
2014-01-01
Sensitivity to complex pitch is notoriously poor in adults with cochlear implants (CIs), but it is unclear whether this is true for children with CIs. Many are implanted today at a very young age, and factors related to brain plasticity (age at implantation, duration of CI experience, and speaking a tonal language) might have strong influences on pitch sensitivity. School-aged children participated, speaking English or Mandarin, having normal hearing (NH) or wearing a CI, using their clinically assigned settings with envelope-based coding strategies. Percent correct was measured in three-interval three-alternative forced choice tasks, for the discrimination of fundamental frequency (F0) of broadband harmonic complexes, and for the discrimination of sinusoidal amplitude modulation rate (AMR) of broadband noise, with reference frequencies at 100 and 200 Hz to focus on voice pitch processing. Data were fitted using a maximum-likelihood technique. CI children displayed higher thresholds and shallower slopes than NH children in F0 discrimination, regardless of linguistic background. Thresholds and slopes were more similar between NH and CI children in AMR discrimination. Once the effect of chronological age was extracted from the variance, the aforementioned factors related to brain plasticity did not contribute significantly to the CI children's sensitivity to pitch. Unless different strategies attempt to encode fine structure information, potential benefits of plasticity may be missed. PMID:25249932
NASA Technical Reports Server (NTRS)
Gibson, Harold M.; Vonder Haar, Thomas H.
1990-01-01
Based on relatively high spatial and temporal resolution satelite data collected at 0700 CST and at each hour from 1000 CST to 1700 CST during the summer of 1986, cloud and convection variations over the area from Mississippi east to Georgia and from the Gulf of Mexico north to Tennessee are discussed. The data analyses show an average maximum cloud frequency over the land areas at 1400 local time and a maximum of deep convection one hour later. Both cloudiness and deep convection are found to be at a maximum during the nocturnal hours over the Gulf of Mexico. Cloud frequency shows a strong relationship to small terrain features. Small fresh water bodies have cloud minima relative to the surroundings in the afternoon hours. Higher, steep terrain shows cloud maxima and the adjacent lower terrain exhibits afternoon cloud minima due to a divergence of mountain breeze caused by the valley.
Preferred modes in jets: comparison between different measures of the receptivity
NASA Astrophysics Data System (ADS)
Garnaud, Xavier; Lesshafft, Lutz; Schmid, Peter J.; Huerre, Patrick
2012-11-01
The response of jets to frequency forcing is usually measured experimentally in terms of the maximum amplitude of velocity fluctuations reached along the axis (Crow & Champagne (1971)). In the present work, the preferred mode of isothermal jets is discussed in terms of the linear flow response to time-harmonic forcing (Trefethen et al. (1993)). The optimal frequency response is computed for different choices of the objective functional: the usual energy (L2) norm and the maximum amplitude over the entire domain (L∞ norm). The relevance and limitations of the different objective functionals are critically analyzed. Although the dominant flow structures are robustly identified in all cases, the measure of the flow response in terms of the maximum amplitude does not suffer from the continually slow axial growth of low frequency perturbations. The financial support of the EADS Foundation is gratefully acknowledged.
Nanoelectromechanical systems: Nanodevice motion at microwave frequencies
NASA Astrophysics Data System (ADS)
Henry Huang, Xue Ming; Zorman, Christian A.; Mehregany, Mehran; Roukes, Michael L.
2003-01-01
It has been almost forgotten that the first computers envisaged by Charles Babbage in the early 1800s were mechanical and not electronic, but the development of high-frequency nanoelectromechanical systems is now promising a range of new applications, including sensitive mechanical charge detectors and mechanical devices for high-frequency signal processing, biological imaging and quantum measurement. Here we describe the construction of nanodevices that will operate with fundamental frequencies in the previously inaccessible microwave range (greater than 1 gigahertz). This achievement represents a significant advance in the quest for extremely high-frequency nanoelectromechanical systems.
Magnitude and frequency of floods in Nebraska
Beckman, Emil W.
1976-01-01
Observed maximum flood peaks at 303 gaging stations with 13 or more years of record and significant peaks at 57 short-term stations and 31 miscellaneous sites are useful in designing flood-control works for maximum safety from flood damage. Comparison is made with maximum observed floods in the United States.
On Frequency Combs in Monolithic Resonators
NASA Astrophysics Data System (ADS)
Savchenkov, A. A.; Matsko, A. B.; Maleki, L.
2016-06-01
Optical frequency combs have become indispensable in astronomical measurements, biological fingerprinting, optical metrology, and radio frequency photonic signal generation. Recently demonstrated microring resonator-based Kerr frequency combs point the way towards chip scale optical frequency comb generator retaining major properties of the lab scale devices. This technique is promising for integrated miniature radiofrequency and microwave sources, atomic clocks, optical references and femtosecond pulse generators. Here we present Kerr frequency comb development in a historical perspective emphasizing its similarities and differences with other physical phenomena. We elucidate fundamental principles and describe practical implementations of Kerr comb oscillators, highlighting associated solved and unsolved problems.
Wilson, J P; Jurjevic, Z; Hanna, W W; Wilson, D M; Potter, T L; Coy, A E
2006-02-01
Pearl millet is widely consumed in regions of Africa and Asia, and is increasingly being grown as an alternative grain in drought-prone regions of the United States. Pearl millet and corn were grown in dryland conditions at Tifton, Georgia, USA and grains were compared for pre-harvest infection by potentially toxigenic fungi and contamination by mycotoxins. Corn hybrids Agripro 9909 and Pioneer 3146, and pearl millet Tifgrain 102 were grown in 2000 and 2001; pearl millet HGM 100 was included in the test in 2001. Hybrids were sown on multiple planting dates in each year to induce variation in flowering time. Host species differed in the frequency of isolation of potentially toxigenic fungal species in both years. Across years, corn hybrids were more prone to infection by Aspergillus flavus Link (maximum isolation frequency = 8.8%) and Fusarium moniliforme Sheldon sensu lato (maximum isolation frequency = 72.8%), with corresponding greater concentrations of aflatoxins (maximum concentration = 204.9 microg kg(-1)) and fumonisins (maximum concentration = 34,039 microg kg(-1)). Pearl millet was more prone to infection by F. semitectum Berk. & Ravenel (maximum isolation = 74.2%) and F. chlamydosporum Wollenweb & Reinking (maximum isolation = 33.0%), and contamination by moniliformin (maximum contamination = 92.1 microg kg(-1)). Beauvericin (maximum concentration = 414.6 microg kg(-1)) was present in both hosts. Planting date of corn affected aflatoxin and beauvericin contamination in 2000, and fumonisin concentration in 2001. The observed differences in mycotoxin contamination of the grains, which are likely due to host-specific differences in susceptibility to pre-harvest mycoflora, may affect food safety when the crops are grown under stress conditions.
INVENTORY OF TREATABILITY STUDY VENDORS - VOLUME 1
The Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) amendments mandate the use of permanent solutions to the maximum extent practicable when remediating Superfund sites. Fundamental to achieving this goal is the use of treatment technologies that red...
INVENTORY OF TREATABILITY STUDY VENDORS - VOLUME 2
The Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) amendments mandate the use of permanent solutions to the maximum extent practicable when remediating Superfund sites. Fundamental to achieving this goal is the use of treatment technologies that r...
Fast and Efficient Stochastic Optimization for Analytic Continuation
Bao, Feng; Zhang, Guannan; Webster, Clayton G; ...
2016-09-28
In this analytic continuation of imaginary-time quantum Monte Carlo data to extract real-frequency spectra remains a key problem in connecting theory with experiment. Here we present a fast and efficient stochastic optimization method (FESOM) as a more accessible variant of the stochastic optimization method introduced by Mishchenko et al. [Phys. Rev. B 62, 6317 (2000)], and we benchmark the resulting spectra with those obtained by the standard maximum entropy method for three representative test cases, including data taken from studies of the two-dimensional Hubbard model. Genearally, we find that our FESOM approach yields spectra similar to the maximum entropy results.more » In particular, while the maximum entropy method yields superior results when the quality of the data is strong, we find that FESOM is able to resolve fine structure with more detail when the quality of the data is poor. In addition, because of its stochastic nature, the method provides detailed information on the frequency-dependent uncertainty of the resulting spectra, while the maximum entropy method does so only for the spectral weight integrated over a finite frequency region. Therefore, we believe that this variant of the stochastic optimization approach provides a viable alternative to the routinely used maximum entropy method, especially for data of poor quality.« less
Visuomotor Tracking Ability of Young Adult Speakers.
ERIC Educational Resources Information Center
Moon, Jerald B.; And Others
1993-01-01
Twenty-five normal young adult speakers tracked sinusoidal and unpredictable target signals using lower lip and jaw movement and fundamental frequency modulation. Tracking accuracy varied as a function of target frequency and articulator used to track. Results show the potential of visuomotor tracking tasks in the assessment of speech articulatory…
ERIC Educational Resources Information Center
Lehtonen, Minna; Hulten, Annika; Rodriguez-Fornells, Antoni; Cunillera, Toni; Tuomainen, Jyrki; Laine, Matti
2012-01-01
We investigated the behavioral and brain responses (ERPs) of bilingual word recognition to three fundamental psycholinguistic factors, frequency, morphology, and lexicality, in early bilinguals vs. monolinguals. Earlier behavioral studies have reported larger frequency effects in bilinguals' nondominant vs. dominant language and in some studies…
47 CFR 15.107 - Conducted limits.
Code of Federal Regulations, 2010 CFR
2010-10-01
... not apply to carrier current systems operating as unintentional radiators on frequencies below 30 MHz... carrier current systems containing their fundamental emission within the frequency band 535-1705 kHz and... 50 μH/50 ohms LISN. (3) Carrier current systems operating below 30 MHz are also subject to the...
NASA Astrophysics Data System (ADS)
Kamarudin, A. F.; Zainal Abidin, M. H.; Mokhatar, S. N.; Daud, M. E.; Ibrahim, A.; Ibrahim, Z.; Noh, M. S. Md
2018-04-01
Natural frequency is the rate at which a body to vibrate or oscillate. Application of ambient vibration (AV) excitation is widely used nowadays as the input motion for building predominant frequency, fo, and ground fundamental frequency, Fo, prediction due to simple, fast, non-destructive, simple handling operation and reliable result. However, it must be emphasized and caution to isolate these frequencies (fo and Fo) from spurious frequencies of site-structure effects especially to low rise building on soft ground deposit. In this study, identification of fo and Fo by using AV measurements were performed on ground and 4-storey primary school reinforced concrete (RC) building at Sekolah Kebangsaan (SK) Sg. Tongkang, Rengit, Johor using 1 Hz of tri-axial seismometer sensor. Overlapping spectra between Fourier Amplitude Spectra (FAS) from and Horizontal to Vertical Spectra Ratio (HVSR) were used to distinguish respective frequencies of building and ground natural frequencies. Three dominant frequencies were identified from the FAS curves at 1.91 Hz, 1.98 Hz and 2.79 Hz in longitudinal (East West-EW), transverse (North South-NS) and vertical (UD) directions. It is expected the building has deformed in translational mode based on the first peak frequency by respective NS and EW components of FAS spectrum. Vertical frequency identified from the horizontal spectrums, might induces to the potential of rocking effect experienced by the school building. Meanwhile, single peak HVSR spectrum at low ground fundamental frequency concentrated at 0.93 Hz indicates to the existence deep contrast of soft deposit. Strong interaction between ground and building at similar frequency (0.93 Hz) observed from the FAS curves on the highest floor has shown the building to behave as a dependent unit against ground response as one rigid mass.
Effect of misspecification of gene frequency on the two-point LOD score.
Pal, D K; Durner, M; Greenberg, D A
2001-11-01
In this study, we used computer simulation of simple and complex models to ask: (1) What is the penalty in evidence for linkage when the assumed gene frequency is far from the true gene frequency? (2) If the assumed model for gene frequency and inheritance are misspecified in the analysis, can this lead to a higher maximum LOD score than that obtained under the true parameters? Linkage data simulated under simple dominant, recessive, dominant and recessive with reduced penetrance, and additive models, were analysed assuming a single locus with both the correct and incorrect dominance model and assuming a range of different gene frequencies. We found that misspecifying the analysis gene frequency led to little penalty in maximum LOD score in all models examined, especially if the assumed gene frequency was lower than the generating one. Analysing linkage data assuming a gene frequency of the order of 0.01 for a dominant gene, and 0.1 for a recessive gene, appears to be a reasonable tactic in the majority of realistic situations because underestimating the gene frequency, even when the true gene frequency is high, leads to little penalty in the LOD score.
FREQUENCY CONTENT OF CARTILAGE IMPACT FORCE SIGNAL REFLECTS ACUTE HISTOLOGIC STRUCTURAL DAMAGE.
Heiner, Anneliese D; Martin, James A; McKinley, Todd O; Goetz, Jessica E; Thedens, Daniel R; Brown, Thomas D
2012-10-01
The objective of this study was to determine if acute cartilage impact damage could be predicted by a quantification of the frequency content of the impact force signal. Osteochondral specimens excised from bovine lateral tibial plateaus were impacted with one of six impact energies. Each impact force signal underwent frequency analysis, with the amount of higher-frequency content (percent of frequency spectrum above 1 KHz) being registered. Specimens were histologically evaluated to assess acute structural damage (articular surface cracking and cartilage crushing) resulting from the impact. Acute histologic structural damage to the cartilage had higher concordance with the high-frequency content measure than with other mechanical impact measures (delivered impact energy, impact maximum stress, and impact maximum stress rate of change). This result suggests that the frequency content of an impact force signal, specifically the proportion of higher-frequency components, can be used as a quick surrogate measure for acute structural cartilage injury. Taking advantage of this relationship could reduce the time and expense of histological processing needed to morphologically assess cartilage damage, especially for purposes of initial screening when evaluating new impaction protocols.
NASA Technical Reports Server (NTRS)
Wintucky, Edwin G.; Simons, Rainee N.
2014-01-01
This paper presents the design, fabrication and test results for a novel waveguide multimode directional coupler (MDC). The coupler fabricated from two dissimilar waveguides is capable of isolating the power at the second harmonic frequency from the fundamental power at the output port of a traveling-wave tube (TWT). In addition to accurate power measurements at harmonic frequencies, a potential application of the MDC is in the design of a beacon source for atmospheric propagation studies at millimeter-wave frequencies.
The influence of low frequency sound on the changes of EEG signal morphology
NASA Astrophysics Data System (ADS)
Damijan, Z.; Wiciak, J.
2006-11-01
The effects of low frequency sound on the changes of morphology of the spectral power density function of EEG signals were studied as a part of the research program f = 40 Hz, Lp = 110 dB HP. The research program involved 33 experiments. A quantitative analysis was conducted of the driving response effect for the fundamental frequency and its harmonics to find the frequency of the driving response effect occurrence depending on the sex of participants.
Thermal Noise Limit in Frequency Stabilization of Lasers with Rigid Cavities
NASA Technical Reports Server (NTRS)
Numata, Kenji; Kemery, Amy; Camp, Jordan
2005-01-01
We evaluated thermal noise (Brownian motion) in a rigid reference cavity Used for frequency stabilization of lasers, based on the mechanical loss of cavity materials and the numerical analysis of the mirror-spacer mechanics with the direct application of the fluctuation dissipation theorem. This noise sets a fundamental limit for the frequency stability achieved with a rigid frequency-reference cavity of order 1 Hz/rtHz at 10mHz at room temperature. This level coincides with the world-highest level stabilization results.
Tape recorder effects on jitter and shimmer extraction.
Doherty, E T; Shipp, T
1988-09-01
To test for possible contamination of acoustic analyses by record/reproduce systems, five sine waves of fixed frequency and amplitude were sampled directly by a computer and recorded simultaneously on four different tape formats (audio and FM reel-to-reel, audio cassette, and video cassette using pulse code modulation). Recordings were digitized on playback and with the direct samples analyzed for fundamental frequency, amplitude, jitter, and shimmer using a zero crossing interpolation scheme. Distortion introduced by any of the data acquisition systems is negligible when extracting average fundamental frequency or average amplitude. For jitter and shimmer estimation, direct sampling or the use of a video cassette recorder with pulse code modulation are clearly superior. FM recorders, although not quite as accurate, provide a satisfactory alternative to those methods. Audio reel-to-reel recordings are marginally adequate for jitter analysis whereas audio cassette recorders can introduce jitter and shimmer values that are greater than some reported values for normal talkers.
The Developmental Dynamics of Terrorist Organizations
Clauset, Aaron; Gleditsch, Kristian Skrede
2012-01-01
We identify robust statistical patterns in the frequency and severity of violent attacks by terrorist organizations as they grow and age. Using group-level static and dynamic analyses of terrorist events worldwide from 1968–2008 and a simulation model of organizational dynamics, we show that the production of violent events tends to accelerate with increasing size and experience. This coupling of frequency, experience and size arises from a fundamental positive feedback loop in which attacks lead to growth which leads to increased production of new attacks. In contrast, event severity is independent of both size and experience. Thus larger, more experienced organizations are more deadly because they attack more frequently, not because their attacks are more deadly, and large events are equally likely to come from large and small organizations. These results hold across political ideologies and time, suggesting that the frequency and severity of terrorism may be constrained by fundamental processes. PMID:23185267
Drew, R; Sapir, S
1995-06-01
Nineteen trained soprano singers aged 18-30 years vocalized tasks designed to assess average speaking fundamental frequency (SFF) during spontaneous speaking and reading. Vocal range and perceptual characteristics while singing with low intensity and high frequency were also assessed, and subjects completed a survey of vocal habits/symptoms. Recorded signals were digitized prior to being analyzed for SFF using the Kay Computerized Speech Lab program. Subjects were assigned to a normal voice or impaired voice group based on ratings of perceptual tasks and survey results. Data analysis showed group differences in mean SFF, no differences in vocal range, higher mean SFF values for reading than speaking, and 58% ability to perceive speaking in low pitch. The role of speaking in too low pitch as causal for vocal symptoms and need for voice classification differentiation in vocal performance studies are discussed.
Acoustic measurement of the surface tension of levitated drops
NASA Technical Reports Server (NTRS)
Trinh, E. H.; Marston, P. L.; Robey, J. L.
1988-01-01
The measurement of the frequency of the fundamental mode of shape oscillation of acoustically levitated drops has been carried out to determine the surface tension of the drop material. Sound fields of about 20 kHz in frequency allow the suspension of drops a few millimeters in size, as well as the necessary drive for oscillations. The surface tension of water, hexadecane, silicone oil, and aqueous solutions of glycerin levitated in air has been measured, and the results have been compared with those obtained with standard ring tensiometry. The two sets of data are in good agreement, the largest discrepancy being about 10 percent. Uncertainties in the effects of the nonspherical static shape of drops levitated in the earth's gravitational field and the rotation state of the sample are the major contributors to the experimental error. A decrease of the resonance frequency of the fundamental mode indicates a soft nonlinearity as the oscillation amplitude increases.
Streaming flow from ultrasound contrast agents by acoustic waves in a blood vessel model.
Cho, Eunjin; Chung, Sang Kug; Rhee, Kyehan
2015-09-01
To elucidate the effects of streaming flow on ultrasound contrast agent (UCA)-assisted drug delivery, streaming velocity fields from sonicated UCA microbubbles were measured using particle image velocimetry (PIV) in a blood vessel model. At the beginning of ultrasound sonication, the UCA bubbles formed clusters and translated in the direction of the ultrasound field. Bubble cluster formation and translation were faster with 2.25MHz sonication, a frequency close to the resonance frequency of the UCA. Translation of bubble clusters induced streaming jet flow that impinged on the vessel wall, forming symmetric vortices. The maximum streaming velocity was about 60mm/s at 2.25MHz and decreased to 15mm/s at 1.0MHz for the same acoustic pressure amplitude. The effect of the ultrasound frequency on wall shear stress was more noticeable. Maximum wall shear stress decreased from 0.84 to 0.1Pa as the ultrasound frequency decreased from 2.25 to 1.0MHz. The maximum spatial gradient of the wall shear stress also decreased from 1.0 to 0.1Pa/mm. This study showed that streaming flow was induced by bubble cluster formation and translation and was stronger upon sonication by an acoustic wave with a frequency near the UCA resonance frequency. Therefore, the secondary radiant force, which is much stronger at the resonance frequency, should play an important role in UCA-assisted drug delivery. Copyright © 2015 Elsevier B.V. All rights reserved.
Skof, B; Strojnik, V
2006-03-01
The aim of this study was to determine the influence of intensive aerobic running on some muscle contractile characteristics and the dynamics of their recovery during a 2 hour period afterwards. Seven well trained runners performed a 6 km run at anaerobic threshold (V(OBLA)). Knee torque during single twitch, low and high frequency electrical stimulation (ES), maximum voluntary knee extension, and muscle activation level test of the quadriceps femoris muscles were measured before and immediately after the run, and at several time points during a 120 minute interval that followed the run. After exercise, the mean (SE) maximum twitch torque (T(TW)) and torque at ES with 20 Hz (low frequency ES; T(F20)) dropped by 14.1 (5.1)% (p<0.05) and 20.6 (7.9)% (p<0.05) respectively, while torque at stimulation with 100 Hz (high frequency ES; T(F100)), maximum isometric knee extension torque (maximum voluntary contraction torque; T(MVC)), and activation level did not change significantly. Twitch contraction time was shortened by 8 (2)% (p<0.05). Ten minutes after the run, T(TW) was 40% higher than immediately after the run and 10% (p<0.05) higher than before the run. T(F20), T(F100), and T(MVC) remained lower for 60 minutes (p<0.05) than before the run. A 6 km continuous run at V(OBLA) caused peripheral fatigue by impairing excitation-contraction coupling. Twitch torque recovered very quickly. However, the process of torque restoration at maximum isometric knee extension torque and at high and low frequency ES took much longer.
Beyond maximum entropy: Fractal pixon-based image reconstruction
NASA Technical Reports Server (NTRS)
Puetter, R. C.; Pina, R. K.
1994-01-01
We have developed a new Bayesian image reconstruction method that has been shown to be superior to the best implementations of other methods, including Goodness-of-Fit (e.g. Least-Squares and Lucy-Richardson) and Maximum Entropy (ME). Our new method is based on the concept of the pixon, the fundamental, indivisible unit of picture information. Use of the pixon concept provides an improved image model, resulting in an image prior which is superior to that of standard ME.
Detection of main tidal frequencies using least squares harmonic estimation method
NASA Astrophysics Data System (ADS)
Mousavian, R.; Hossainali, M. Mashhadi
2012-11-01
In this paper the efficiency of the method of Least Squares Harmonic Estimation (LS-HE) for detecting the main tidal frequencies is investigated. Using this method, the tidal spectrum of the sea level data is evaluated at two tidal stations: Bandar Abbas in south of Iran and Workington on the eastern coast of the UK. The amplitudes of the tidal constituents at these two tidal stations are not the same. Moreover, in contrary to the Workington station, the Bandar Abbas tidal record is not an equispaced time series. Therefore, the analysis of the hourly tidal observations in Bandar Abbas and Workington can provide a reasonable insight into the efficiency of this method for analyzing the frequency content of tidal time series. Furthermore, applying the method of Fourier transform to the Workington tidal record provides an independent source of information for evaluating the tidal spectrum proposed by the LS-HE method. According to the obtained results, the spectrums of these two tidal records contain the components with the maximum amplitudes among the expected ones in this time span and some new frequencies in the list of known constituents. In addition, in terms of frequencies with maximum amplitude; the power spectrums derived from two aforementioned methods are the same. These results demonstrate the ability of LS-HE for identifying the frequencies with maximum amplitude in both tidal records.
Nosek, Jaroslav; Pustka, Martin
2006-01-01
The quartz homeotype gallium orthophosphate (GaPO4) is a representative of piezoelectric single crystals of large electromechanical coupling factor. It is known that its coupling factor kappa26 associated with the resonators vibrating in the thickness-shear mode is approximately two times greater than that of quartz. This property increases the spacing between the series and parallel resonance frequencies of resonators, as well as the difference between the resonance frequency temperature dependencies of the fundamental and harmonic resonance frequencies of resonators vibrating in the thickness-shear mode. In this paper, the methods for determination of the coupling factor kappa26 are presented, and the computed values are compared with the measured ones. The influence of the coupling factor to the resonance-frequency temperature dependencies of the fundamental and third harmonics of selected rotated Y-cut GaPO4 resonators vibrating in the thickness-shear mode is presented. The purely elastic case for a laterally unbounded plate, which corresponds closely to the limiting case of high harmonic resonance frequency-temperature behavior was assumed for the calculations. The computed temperature coefficients for the Y-cut orientation and calculated turnover point temperatures TTP for different (YX1) orientations are presented.
Zhu, Li; Bharadwaj, Hari; Xia, Jing; Shinn-Cunningham, Barbara
2013-01-01
Two experiments, both presenting diotic, harmonic tone complexes (100 Hz fundamental), were conducted to explore the envelope-related component of the frequency-following response (FFRENV), a measure of synchronous, subcortical neural activity evoked by a periodic acoustic input. Experiment 1 directly compared two common analysis methods, computing the magnitude spectrum and the phase-locking value (PLV). Bootstrapping identified which FFRENV frequency components were statistically above the noise floor for each metric and quantified the statistical power of the approaches. Across listeners and conditions, the two methods produced highly correlated results. However, PLV analysis required fewer processing stages to produce readily interpretable results. Moreover, at the fundamental frequency of the input, PLVs were farther above the metric's noise floor than spectral magnitudes. Having established the advantages of PLV analysis, the efficacy of the approach was further demonstrated by investigating how different acoustic frequencies contribute to FFRENV, analyzing responses to complex tones composed of different acoustic harmonics of 100 Hz (Experiment 2). Results show that the FFRENV response is dominated by peripheral auditory channels responding to unresolved harmonics, although low-frequency channels driven by resolved harmonics also contribute. These results demonstrate the utility of the PLV for quantifying the strength of FFRENV across conditions. PMID:23862815
A physiological frequency-position map of the chinchilla cochlea.
Müller, Marcus; Hoidis, Silvi; Smolders, Jean W T
2010-09-01
Accumulating evidence indicates that mammalian cochlear frequency-position maps (location of maximum vibration of the basilar membrane as a function of frequency) depend on the physiological condition of the inner ear. Cochlear damage desensitizes the ear, after the damage the original location of maximum vibration is tuned to a lower sound frequency. This suggests that frequency-position maps, derived from such desensitized ears, are shifted to lower frequencies, corresponding to a shift of the basilar membrane vibration pattern towards the base for a given stimulus frequency. To test this hypothesis, we re-mapped the cochlear frequency-position map in the chinchilla. We collected frequency-position data from chinchillas in normal physiological condition ("physiological map") and compared these to data previously established from sound overexposed ears ("anatomical map"). The characteristic frequency (CF) of neurons in the cochlear nucleus was determined. Horse-radish peroxidase (HRP) or biocytin (BCT) were injected iontophoretically to trace auditory nerve fibers towards their innervation site in the organ of Corti. The relationship between distance from the base (d, percent) and frequency (f, kHz) was described best by a simple exponential function: d = 61.2 - 42.2 x log(f). The slope of the function was 2.55 mm/octave. Compared to the "anatomical map", the "physiological map" was shifted by about 0.3 octaves to higher frequencies corresponding to a shift of the basilar membrane vibration pattern of 0.8 mm towards the apex for a given stimulus frequency. Our findings affirm that frequency-position maps in the mammalian cochlea depend on the condition of the inner ear. Damage-induced desensitization in mammalian inner ears results in similar shifts of CF (about 0.5 octaves) but different shifts of the maximum of the vibration pattern towards the base at given frequencies, dependent on the mapping constant of the species, longer basilar membranes showing a larger basal shift. Furthermore, the results substantiate the notion that "crowding" at lower frequencies appears to be a specialization rather than a general feature. Copyright (c) 2010 Elsevier B.V. All rights reserved.