Propagation distance-resolved characteristics of filament-induced copper plasma
Ghebregziabher, Isaac; Hartig, Kyle C.; Jovanovic, Igor
2016-03-02
Copper plasma generated at different filament-copper interaction points was characterized by spectroscopic, acoustic, and imaging measurements. The longitudinal variation of the filament intensity was qualitatively determined by acoustic measurements in air. The maximum plasma temperature was measured at the location of peak filament intensity, corresponding to the maximum mean electron energy during plasma formation. The highest copper plasma density was measured past the location of the maximum electron density in the filament, where spectral broadening of the filament leads to enhanced ionization. Acoustic measurements in air and on solid target were correlated to reconstructed plasma properties. Lastly, optimal line emissionmore » is measured near the geometric focus of the lens used to produce the filament.« less
Laser plasma interaction at an early stage of laser ablation
NASA Astrophysics Data System (ADS)
Lu, Y. F.; Hong, M. H.; Low, T. S.
1999-03-01
Laser scattering and its interaction with plasma during KrF excimer laser ablation of silicon are investigated by ultrafast phototube detection. There are two peaks in an optical signal with the first peak attributed to laser scattering and the second one to plasma generation. For laser fluence above 5.8 J/cm2, the second peak rises earlier to overlap with the first one. The optical signal is fitted by a pulse distribution for the scattered laser light and a drifted Maxwell-Boltzmann distribution with a center-of-mass velocity for the plasma. Peak amplitude and its arrival time, full width at half maximum (FWHM), starting time, and termination time of the profiles are studied for different laser fluences and detection angles. Laser pulse is scattered from both the substrate and the plasma with the latter part as a dominant factor during the laser ablation. Peak amplitude of the scattered laser signal increases but its FWHM decreases with the laser fluence. Angular distribution of the peak amplitude can be fitted with cosn θ(n=4) while the detection angle has no obvious influence on the FWHM. In addition, FWHM and peak amplitude of plasma signal increase with the laser fluence. However, starting time and peak arrival time of plasma signal reduce with the laser fluence. The time interval between plasma starting and scattered laser pulse termination is proposed as a quantitative parameter to characterize laser plasma interaction. Threshold fluence for the interaction is estimated to be 3.5 J/cm2. For laser fluence above 12.6 J/cm2, the plasma and scattered laser pulse distributions tend to saturate.
The pharmacokinetics of intraosseous atropine in hypovolemic swine.
Yost, Jonathan; Baldwin, Phillip; Bellenger, Sarah; Bradshaw, Freida; Causapin, Edna; Demotica, Richelle; Livingston, Michael; Lee, Cynthia; Gegel, Brian; Burgert, James; Claessens, Adam; Johnson, Don; Loughren, Michael
2015-01-01
Compare the pharmacokinetics of atropine administered via the intravenous (IV), intramuscular (IM), and intraosseous (IO) routes in a normovolemic and hypovolemic swine model. Prospective, between subjects, experimental study. Vivarium. Yorkshire-cross swine (N = 36). Atropine was administered via IV, IM, or IO routes to normovolemic and hypovolemic swine. Blood samples were drawn at regular intervals after atropine administration and analyzed for plasma atropine concentration. Pharmacokinetic parameters were obtained from modeling the plasma concentrations. Pharmacokinetic parameters, maximum concentration (Cmax) and time to maximum concentration (Tmax). The IV and IO groups in both the normovolemic and hypovolemic models reached peak plasma concentration immediately and had a very rapid distribution phase with no apparent absorption phase for the IO groups. Peak plasma concentration and time to reach peak concentration were both significantly lower for the IM groups. There was a significant increase in absorption time with IM administration in the hypovolemic model compared to the normovolemic model. The IO route is an effective method of administering atropine and is comparable to the IV route even under conditions of significant hemorrhage. Therapeutic levels of atropine may be delayed and possibly difficult to obtain via IM injection in the presence of hypovolemic shock.
NASA Astrophysics Data System (ADS)
Lei, J.; Geng, Y.; Liu, K.; Zhu, W.; Zheng, Z.; Hu, H.
2017-12-01
In this paper, pulsating direct current air-water plasma jet, which can increase the production of •OH and decrease the temperature, is studied. The results show that the discharge mode changes in one cycle from corona discharge with steep Trichel current pulse to glow-like discharge. It is unknown whether the different discharge modes and water ratio have an effect on the transient process of the excited O and •OH production and the mechanism of plasma propagation. So, a series of experiments are done in this paper. The results show that the changing rules of both the excited state O and the discharge current reach their two peak values synchronously. And its maximum appears at the time of the first peak current value in corona mode. However, the change of the excited state •OH is different. It increases to its maximum at the time of the second peak current value in glow-like mode. Besides, the intensified charge coupled device photographs show that the luminous intensity of the discharge zone at the first peak current value in corona mode is stronger than the second peak current value in glow-like mode. At the same time, the discharge area of the former is larger than the latter. Nevertheless, with the increase in water ratio, the discharge area change reversed. Additionally, the air plasma plume propagation depends on the gas flow. The initial propagation velocity decreases with the increase in water ratio.
Postprandial plasma D-lactate concentrations after yogurt ingestion.
de Vrese, M; Barth, C A
1991-06-01
The risk of D-lactic acidosis after consumption of yogurt was investigated in seven healthy volunteers. After ingestion of yogurt containing 1.06 mmol/kg body weight, D-lactic acid postprandial plasma D-lactate concentrations increased from 0.070 +/- 0.020 to a maximum of 0.200 +/- 0.010 mmol/l within 60 min. That was half the maximum concentration after the equivalent amount of D-lactate in the form of an aqueous solution of DL-lactate. The shape of the postprandial plasma D-lactate peak was flatter, but much broader after yogurt than after the aqueous solution, the peak areas being equal. When 0.64 mmol/kg body weight D-lactate were consumed as yogurt, plasma concentrations amounted to 0.086 +/- 0.030 mmol/l. Signs of a mild, transient, compensated metabolic acidosis, which was apparent in case of the aqueous lactic acid solution did not occur in case of yogurt. It is concluded that the consumption of foods containing D-lactic acid gives no reason for concern in healthy adults.
Paracetamol suppositories: a comparative study.
Cullen, S; Kenny, D; Ward, O C; Sabra, K
1989-01-01
Paracetamol suppositories in two different bases were given to children who had fever after operations. Plasma concentrations and the effect on temperature were compared. There was a significant correlation between peak plasma concentrations and maximum drop in temperature. A lipophilic base produced better results than a hydrophilic base. PMID:2817936
NASA Astrophysics Data System (ADS)
Sears, Jason; Schmidt, Andrea; Link, Anthony; Welch, Dale
2016-10-01
Experiments have suggested that dense plasma focus (DPF) neutron yield increases with faster drivers [Decker NIMP 1986]. Using the particle-in-cell code LSP [Schmidt PRL 2012], we reproduce this trend in a kJ DPF [Ellsworth 2014], and demonstrate how driver rise time is coupled to neutron output. We implement a 2-D model of the plasma focus including self-consistent circuit-driven boundary conditions. Driver capacitance and voltage are varied to modify the current rise time, and anode length is adjusted so that run-in coincides with the peak current. We observe during run down that magnetohydrodynamic (MHD) instabilities of the sheath shed blobs of plasma that remain in the inter-electrode gap during run in. This trailing plasma later acts as a low-inductance restrike path that shunts current from the pinch during maximum compression. While the MHD growth rate increases slightly with driver speed, the shorter anode of the fast driver allows fewer e-foldings and hence reduces the trailing mass between electrodes. As a result, the fast driver postpones parasitic restrikes and maintains peak current through the pinch during maximum compression. The fast driver pinch therefore achieves best simultaneity between its ion beam and peak target density, which maximizes neutron production. Prepared by LLNL under Contract DE-AC52-07NA27344.
NASA Astrophysics Data System (ADS)
Arif Malik, Muhammad; Hughes, David
2016-04-01
Improvements in ozone synthesis from air and oxygen by increasing the number density of plasma channels and lower voltage for the same specific input energy (SIE) were explored in a nonthermal plasma based on a sliding discharge. The number of plasma channels and energy per pulse increased in direct proportion to the increase in the effective length of the anode (the high voltage electrode). Decreasing the discharge gap increased the energy per pulse for the same length and allowed the installation of more electrode pairs in the same space. It allowed the increase of the number of plasma channels in the same space to achieve the same SIE at a lower peak voltage with less energy per plasma channel. The ozone concentration gradually increased to ~1500 ppmv (140 to 50 g kWh-1) from air and to ~6000 ppmv (400 to 200 g kWh-1) from oxygen with a gradual increase in the SIE to ~200 J L-1, irrespective of the variations in electrode geometry, applied voltage or flow rate of the feed gas. A gradual increase in SIE beyond 200 J L-1 gradually increased the ozone concentration to a certain maximum value followed by a decline, but the rate of increase and the maximum value was higher for the greater number of plasma channels and lower peak voltage combination. The maximum ozone concentration was ~5000 ppmv (~30 g kWh-1) from air and ~22 000 ppmv (~80 g kWh-1) from oxygen. The results are explained on the basis of characteristics of the plasma and ozone synthesis mechanism.
Pharmacology of 13-cis-retinoic acid in humans.
Kerr, I G; Lippman, M E; Jenkins, J; Myers, C E
1982-05-01
Vitamin A and its analogs (retinoids) have shown great promise for the chemoprevention of cancer as well as being a possible new class of chemotherapeutic agents. A Phase I and II trial of 13-cis-retinoic acid in advanced cancers was initiated, and the clinical pharmacology of the drug was studied. All patients received p.o. 13-cis-retinoic acid starting at 0.5 mg/kg/day, escalating over 4 weeks to a maximum dose of 8 mg/kg/day in divided doses. Although there was a linear correlation of plasma concentration with dose escalation, large inter-individual variations in peak plasma concentrations were noted. At the maximum drug dose, the mean peak plasma concentration was 4 X 10(-6) M. There was little drug accumulation on this schedule, as trough concentrations between p.o. doses often dropped below 1 X 10(-6) M. The drug was metabolized extensively to a metabolite, the concentrations of which exceeding parent 13-cis-retinoic acid concentrations with chronic dosing. Retinol concentrations were below the normal range.
Plasma-filled diode based on the coaxial gun
NASA Astrophysics Data System (ADS)
Zherlitsyn, A. A.; Kovalchuk, B. M.; Pedin, N. N.
2012-10-01
The paper presents the results of studies of a coaxial gun for a plasma-filled electron diode. Effects of the discharge channel diameter and gun current on characteristics of the plasma and pulse generated in the diode were investigated. The electron beam with maximum energy of ≥1 MeV at the current of ≈100 kA was obtained in the experiments with a plasma-filled diode. The energy of ≈5 kJ with the peak power of ≥100 GW dissipated in the diode.
Plasma-filled diode based on the coaxial gun.
Zherlitsyn, A A; Kovalchuk, B M; Pedin, N N
2012-10-01
The paper presents the results of studies of a coaxial gun for a plasma-filled electron diode. Effects of the discharge channel diameter and gun current on characteristics of the plasma and pulse generated in the diode were investigated. The electron beam with maximum energy of ≥1 MeV at the current of ≈100 kA was obtained in the experiments with a plasma-filled diode. The energy of ≈5 kJ with the peak power of ≥100 GW dissipated in the diode.
Native fluorescence characterization of human liver abnormalities
NASA Astrophysics Data System (ADS)
Ganesan, Singaravelu; Madhuri, S.; Aruna, Prakasa R.; Suchitra, S.; Srinivasan, T. G.
1999-05-01
Fluorescence spectroscopy of intrinsic biomolecules has been extensively used in biology and medicine for the past several decades. In the present study, we report the native fluorescence characteristics of blood plasma from normal human subjects and patients with different liver abnormalities such as hepatitis, leptospirosis, jaundice, cirrhosis and liver cell failure. Native fluorescence spectra of blood plasma -- acetone extract were measured at 405 nm excitation. The average spectrum of normal blood plasma has a prominent emission peak around 464 nm whereas in the case of liver diseased subjects, the primary peak is red shifted with respect to normal. In addition, liver diseased cases show distinct secondary emission peak around 615 nm, which may be attributed to the presence of endogenous porphyrins. The red shift of the prominent emission peak with respect to normal is found to be maximum for hepatitis and minimum for cirrhosis whereas the secondary emission peak around 615 nm was found to be more prominent in the case of cirrhosis than the rest. The ratio parameter I465/I615 is found to be statistically significant (p less than 0.001) in discriminating liver abnormalities from normal.
Statistical results from 10 years of Cassini Langmuir probe plasma measurements
NASA Astrophysics Data System (ADS)
Holmberg, M.; Shebanits, O.; Wahlund, J. E.; Morooka, M.; Andre, N.
2016-12-01
We use a new analysis method to obtain 10 years of Cassini RPWS Langmuir probe (LP) measurements to study the structure and dynamics of the inner plasma disk of Saturn. The LP plasma density measurements show good agreement with electron densities derived from the RPWS electric field power spectra and confirms and/or improves a number of previous findings about the structure of the plasma disk. E.g., the Enceladus plume is detected as a localised density maximum at the orbit of Enceladus, but the peak density of the inner plasma disk, excluding Enceladus plume passages, is located closer to 4.7 Rs. No density peaks are recorded at the orbits of the moons Mimas, Tethys, Dione, and Rhea. We confirm the previously detected plasma density dayside/nightside asymmetry, which is likely due to a particle drift in the dusk to dawn direction. Presented is also the LP result on the seasonal dependence of the plasma disk within Enceladus' orbit.
NASA Astrophysics Data System (ADS)
Kim, Y.; Kim, J.; Lee, C.; Jee, G.
2008-12-01
A VHF meteor radar at King Sejong Station (62°S, 58°W), Antarctica has been detecting echoes from more than 20,000 meteors per day since March 2007. Meteor echoes are decayed typically within seconds as meteor trail plasma spread away or are neutralized. Assuming that diffusion is the only process for decay of meteor echo signals, the atmospheric temperatures and pressures have been inferred from the measured meteor decay times at the peak meteor altitudes around 90 km. In this study, we analyze altitude profiles of meteor decay times in each month, which clearly show a maximum at 80 ~ 85 km. The maximum appears at higher altitude during austral summer than winter. The fast decay of meteor signals below the maximum cannot be explained by atmospheric diffusion which decreases with increasing atmospheric densities. We find that the measured meteor decay time profiles can be fitted with a loss rate profile, in addition to diffusion, with a peak altitude of 55 ~ 73 km and a peak rate of 4 ~ 15 sec- 1. The additional loss of meteor plasma may be due to electron absorption by icy particles in the mesosphere, but the estimated peak altitudes are much lower than the layers of NLC or PME. The estimated peak loss rates seem to be too large to be accounted by absorption by icy or dust particles. We will discuss other processes to explain the fast meteor times and their variation over season.
Ahmad, Mahmoud M; Abdel-Wahab, Essam A; El-Maaref, A A; Rawway, Mohammed; Shaaban, Essam R
2014-01-01
The irradiation effect of argon, oxygen glow discharge plasma, and mercury lamp on silver and agar/silver nanoparticle samples is studied. The irradiation time dependence of the synthesized silver and agar/silver nanoparticle absorption spectra and their antibacterial effect are studied and compared. In the agar/silver nanoparticle sample, as the irradiation time of argon glow discharge plasma or mercury lamp increases, the peak intensity and the full width at half maximum, FWHM, of the surface plasmon resonance absorption band is increased, however a decrease of the peak intensity with oxygen glow plasma has been observed. In the silver nanoparticle sample, as the irradiation time of argon, oxygen glow discharge plasma or mercury lamp increases, the peak intensity of the surface plasmon resonance absorption band is increased, however, there is no significant change in the FWHM of the surface plasmon resonance absorption band. The SEM results for both samples showed nanoparticle formation with mean size about 50 nm and 40 nm respectively. Throughout the irradiation time with the argon, oxygen glow discharge plasma or mercury lamp, the antibacterial activity of several kinds of Gram-positive and Gram-negative bacteria has been examined.
Roberts, J; Waller, D G; von Renwick, A G; O'Shea, N; Macklin, B S; Bulling, M
1996-04-01
1. The effects of benzhexol on the absorption and pharmacokinetics of an oral dose of levodopa have been studied in 10 young healthy volunteers. Subjects were given a suspension of levodopa (250 mg) 90 min after either benzhexol (5 mg) or placebo in a randomized cross over design with doses separated by at least 1 week; on each occasion carbidopa was given 1 h before and 5 h after the dose of levodopa. Soluble paracetamol and radiolabelled DTPA were given with the levodopa as markers of gastric emptying. 2. Most subjects showed two peaks in the levodopa plasma concentration-time curve on the placebo day, with the second minor peak occurring 1-2 h after the dose. After benzhexol administration all subjects showed two or more peak levodopa concentrations in plasma. Benzhexol administration caused a significant decrease in the maximum concentration (43%; P < 0.05) of the initial peak and an increase (22%; P < 0.1) in the maximum concentration of the second peak. This change in absorption profile caused by benzhexol significantly altered the ratios of the second peak compared with the initial peak for both the maximum concentrations (P < 0.02) and for the AUC values (P < 0.05). Benzhexol administration did not affect the total AUC of levodopa (7.30 +/- 1.09 vs 7.19 +/- 1.26 micrograms ml-1 h; means +/- s.d.). 3. The plasma concentration-time curves for paracetamol showed similar profiles to those for levodopa and the ratios of the peak concentrations and AUC values for the second peak compared with the initial peak were increased significantly by benzhexol administration (P < 0.05). The total AUC of paracetamol was not affected by benzhexol administration (39.4 +/- 8.2 vs 40.0 +/- 8.9 micrograms ml-1 h; mean +/- s.d.) 4. Benzhexol altered the gastric emptying profile, shown by gamma-scintigraphy, with a reduced extent of initial emptying prior to the establishment of the plateau which is characteristic of levodopa administration in the fasting state. In consequence the ratio of the second to the initial phase of emptying was significantly higher (P < 0.01) following benzhexol treatment. 5. Benzhexol reduces the initial phase of gastric emptying after a dose of levodopa so that there is a decrease in the initial peak and a greater proportion of the dose is absorbed subsequently following the second phase of gastric emptying which occurs approximately 1 h later. Theoretically, this altered concentration-time profile could be an advantage for some patients with Parkinson's disease.
Magnetosheath electrostatic turbulence
NASA Technical Reports Server (NTRS)
Rodriquez, P.
1977-01-01
The spectrum of electrostatic plasma waves in the terrestrial magnetosheath was studied using the plasma wave experiment on the IMP-6 satellite. Electrostatic plasma wave turbulence is almost continuously present throughout the magnetosheath with broadband (20 Hz- 70 kHz) r.m.s. field intensities typically 0.01 - 1.0 millivolts/m. Peak intensities of about 1.0 millivolts/m near the electron plasma frequency (30 - 60 kHz) were detected occasionally. The components usually identified in the spectrum of magnetosheath electrostatic turbulence include a high frequency ( or = 30 kHz) component peaking at the electron plasma frequency f sub pe, a low frequency component with a broad intensity maximum below the nominal ion plasma frequency f sub pi (approximately f sub pe/43), and a less well defined intermediate component in the range f sub pi f f sub pe. The intensity distribution of magnetosheath electrostatic turbulence clearly shows that the low frequency component is associated with the bow shock, suggesting that the ion heating begun at the shock continues into the downstream magnetosheath.
Ion energy distributions in silane-hydrogen plasmas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamers, E.A.G.; Sark, W.G.J.H.M. van; Bezemer, J.
1996-12-31
For the first time ion energy distributions (IED) of different ions from silane-hydrogen (SiH{sub 4}-H{sub 2}) RF plasmas are presented, i.e., the distributions of SiH{sub 3}{sup +}, SiH{sub 2}{sup +} and Si{sub 2}H{sub 4}{sup +}. The energy distributions of SiH{sub 3}{sup +} and SiH{sub 2}{sup +} ions show peaks, which are caused by a charge exchange process in the sheath. A method is presented by which the net charge density in the sheath is determined from the plasma potential and the energy positions of the charge exchange peaks. Knowing the net charge density in the sheath and the plasma potential,more » the sheath thickness can be determined and an estimation of the absolute ion fluxes can be made. The flux of ions can, at maximum, account for 10% of the observed deposition rate.« less
ROBERTS, J.; WALLER, D. G.; RENWICK, A. G.; O'SHEA, N.; MACKLIN, B. S.; BULLING, M.
1996-01-01
1 The effects of benzhexol on the absorption and pharmacokinetics of an oral dose of levodopa have been studied in 10 young healthy volunteers. Subjects were given a suspension of levodopa (250 mg) 90 min after either benzhexol (5 mg) or placebo in a randomized cross over design with doses separated by at least 1 week; on each occasion carbidopa was given 1 h before and 5 h after the dose of levodopa. Soluble paracetamol and radiolabelled DTPA were given with the levodopa as markers of gastric emptying. 2 Most subjects showed two peaks in the levodopa plasma concentration–time curve on the placebo day, with the second minor peak occurring 1–2 h after the dose. After benzhexol administration all subjects showed two or more peak levodopa concentrations in plasma. Benzhexol administration caused a significant decrease in the maximum concentration (43%; P<0.05) of the initial peak and an increase (22%; P<0.1) in the maximum concentration of the second peak. This change in absorption profile caused by benzhexol significantly altered the ratios of the second peak compared with the initial peak for both the maximum concentrations (P<0.02) and for the AUC values (P<0.05). Benzhexol administration did not affect the total AUC of levodopa (7.30±1.09 vs 7.19±1.26 μg ml−1 h; means±s.d.). 3 The plasma concentration–time curves for paracetamol showed similar profiles to those for levodopa and the ratios of the peak concentrations and AUC values for the second peak compared with the initial peak were increased significantly by benzhexol administration (P<0.05). The total AUC of paracetamol was not affected by benzhexol administration (39.4±8.2 vs 40.0±8.9 μg ml−1 h; mean±s.d.) 4 Benzhexol altered the gastric emptying profile, shown by γ-scintigraphy, with a reduced extent of initial emptying prior to the establishment of the plateau which is characteristic of levodopa administration in the fasting state. In consequence the ratio of the second to the initial phase of emptying was significantly higher (P<0.01) following benzhexol treatment. 5 Benzhexol reduces the initial phase of gastric emptying after a dose of levodopa so that there is a decrease in the initial peak and a greater proportion of the dose is absorbed subsequently following the second phase of gastric emptying which occurs approximately 1 h later. Theoretically, this altered concentration-time profile could be an advantage for some patients with Parkinson's disease. PMID:8730980
Metabolism of 14C-labeled doxylamine succinate (Bendectin) in the rhesus monkey (Macaca mulatta).
Slikker, W; Holder, C L; Lipe, G W; Korfmacher, W A; Thompson, H C; Bailey, J R
1986-01-01
The time-course of the metabolic fate of [14C]doxylamine was determined after the p.o. administration of 13 mg/kg doxylamine succinate as Bendectin plus [14C]doxylamine succinate to the rhesus monkey. Urine and plasma samples were analyzed by reversed-phase high performance liquid chromatography (HPLC), chemical derivatization, and mass spectrometry. The cumulative 48-hr urinary metabolic profile contained 81% of the administered radiolabeled dose and consisted of at least six radiolabeled peaks. They were peak 1: unknown polar metabolites (8% of dose); peak 2: 2-[1-phenyl-1-(2-pyridinyl)ethoxy] acetic acid, 1-[1-phenyl-1(2-pyridinyl)ethoxy] methanol, and another minor metabolite(s) (31%); peak 3: doxylamine-N-oxide (1%); peak 4a: N,N-didesmethyldoxylamine (17%); peak 4b: doxylamine (4%); and peak 5: N-desmethyldoxylamine (20%). The plasma metabolic profile was the same as the urinary profile except for the absence of doxylamine-N-oxide. The maximum plasma concentrations and elapsed time to attain these concentrations were as follows. Peak 1: 540 ng/mL, 4 hr; peak 2: 1700 ng/mL, 1 hr; peak 4a: 430 ng/mL, 4 hr; peak 4b: 930 ng/mL, 2 hr; and peak 5: 790 ng/mL, 2 hr. These data suggest that in the monkey, doxylamine metabolism follows at least four pathways: a minor pathway to the N-oxide; a minor pathway to unknown polar metabolites; a major pathway to mono- and didesmethyldoxylamine via successive N-demethylation; and a major pathway to side-chain cleavage products (peak 2) via direct side-chain oxidation and/or deamination.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slikker, W. Jr.; Holder, C.L.; Lipe, G.W.
The time-course of the metabolic fate of (/sup 14/C)doxylamine was determined after the p.o. administration of 13 mg/kg doxylamine succinate as Bendectin plus (/sup 14/C)doxylamine succinate to the rhesus monkey. Urine and plasma samples were analyzed by reversed-phase high performance liquid chromatography (HPLC), chemical derivatization, and mass spectrometry. The cumulative 48-hr urinary metabolic profile contained 81% of the administered radiolabeled dose and consisted of at least six radiolabeled peaks. They were peak 1: unknown polar metabolites (8% of dose); peak 2: 2-(1-phenyl-1-(2-pyridinyl)ethoxy) acetic acid, 1-(1-phenyl-1(2-pyridinyl)ethoxy) methanol, and another minor metabolite(s) (31%); peak 3: doxylamine-N-oxide (1%); peak 4a: N,N-didesmethyldoxylamine (17%); peakmore » 4b: doxylamine (4%); and peak 5: N-desmethyldoxylamine (20%). The plasma metabolic profile was the same as the urinary profile except for the absence of doxylamine-N-oxide. The maximum plasma concentrations and elapsed time to attain these concentrations were as follows. Peak 1: 540 ng/mL, 4 hr; peak 2: 1700 ng/mL, 1 hr; peak 4a: 430 ng/mL, 4 hr; peak 4b: 930 ng/mL, 2 hr; and peak 5: 790 ng/mL, 2 hr. These data suggest that in the monkey, doxylamine metabolism follows at least four pathways: a minor pathway to the N-oxide; a minor pathway to unknown polar metabolites; a major pathway to mono- and didesmethyldoxylamine via successive N-demethylation; and a major pathway to side-chain cleavage products (peak 2) via direct side-chain oxidation and/or deamination.« less
Transport of ion beam in an annular magnetically expanding helicon double layer thruster
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Yunchao, E-mail: yunchao.zhang@anu.edu.au; Charles, Christine; Boswell, Rod
2014-06-15
An ion beam generated by an annular double layer has been measured in a helicon thruster, which sustains a magnetised low-pressure (5.0 × 10{sup −4} Torr) argon plasma at a constant radio-frequency (13.56 MHz) power of 300 W. After the ion beam exits the annular structure, it merges into a solid centrally peaked structure in the diffusion chamber. As the annular ion beam moves towards the inner region in the diffusion chamber, a reversed-cone plasma wake (with a half opening angle of about 30°) is formed. This process is verified by measuring both the radial and axial distributions of the beam potential and beammore » current. The beam potential changes from a two-peak radial profile (maximum value ∼ 30 V, minimum value ∼ 22.5 V) to a flat (∼28 V) along the axial direction; similarly, the beam current changes from a two-peak to one-peak radial profile and the maximum value decreases by half. The inward cross-magnetic-field motion of the beam ions is caused by a divergent electric field in the source. Cross-field diffusion of electrons is also observed in the inner plume and is determined as being of non-ambipolar origin.« less
Experimental discrimination of ion stopping models near the Bragg peak in highly ionized matter.
Cayzac, W; Frank, A; Ortner, A; Bagnoud, V; Basko, M M; Bedacht, S; Bläser, C; Blažević, A; Busold, S; Deppert, O; Ding, J; Ehret, M; Fiala, P; Frydrych, S; Gericke, D O; Hallo, L; Helfrich, J; Jahn, D; Kjartansson, E; Knetsch, A; Kraus, D; Malka, G; Neumann, N W; Pépitone, K; Pepler, D; Sander, S; Schaumann, G; Schlegel, T; Schroeter, N; Schumacher, D; Seibert, M; Tauschwitz, An; Vorberger, J; Wagner, F; Weih, S; Zobus, Y; Roth, M
2017-06-01
The energy deposition of ions in dense plasmas is a key process in inertial confinement fusion that determines the α-particle heating expected to trigger a burn wave in the hydrogen pellet and resulting in high thermonuclear gain. However, measurements of ion stopping in plasmas are scarce and mostly restricted to high ion velocities where theory agrees with the data. Here, we report experimental data at low projectile velocities near the Bragg peak, where the stopping force reaches its maximum. This parameter range features the largest theoretical uncertainties and conclusive data are missing until today. The precision of our measurements, combined with a reliable knowledge of the plasma parameters, allows to disprove several standard models for the stopping power for beam velocities typically encountered in inertial fusion. On the other hand, our data support theories that include a detailed treatment of strong ion-electron collisions.
Experimental discrimination of ion stopping models near the Bragg peak in highly ionized matter
NASA Astrophysics Data System (ADS)
Cayzac, W.; Frank, A.; Ortner, A.; Bagnoud, V.; Basko, M. M.; Bedacht, S.; Bläser, C.; Blažević, A.; Busold, S.; Deppert, O.; Ding, J.; Ehret, M.; Fiala, P.; Frydrych, S.; Gericke, D. O.; Hallo, L.; Helfrich, J.; Jahn, D.; Kjartansson, E.; Knetsch, A.; Kraus, D.; Malka, G.; Neumann, N. W.; Pépitone, K.; Pepler, D.; Sander, S.; Schaumann, G.; Schlegel, T.; Schroeter, N.; Schumacher, D.; Seibert, M.; Tauschwitz, An.; Vorberger, J.; Wagner, F.; Weih, S.; Zobus, Y.; Roth, M.
2017-06-01
The energy deposition of ions in dense plasmas is a key process in inertial confinement fusion that determines the α-particle heating expected to trigger a burn wave in the hydrogen pellet and resulting in high thermonuclear gain. However, measurements of ion stopping in plasmas are scarce and mostly restricted to high ion velocities where theory agrees with the data. Here, we report experimental data at low projectile velocities near the Bragg peak, where the stopping force reaches its maximum. This parameter range features the largest theoretical uncertainties and conclusive data are missing until today. The precision of our measurements, combined with a reliable knowledge of the plasma parameters, allows to disprove several standard models for the stopping power for beam velocities typically encountered in inertial fusion. On the other hand, our data support theories that include a detailed treatment of strong ion-electron collisions.
Experimental discrimination of ion stopping models near the Bragg peak in highly ionized matter
Cayzac, W.; Frank, A.; Ortner, A.; Bagnoud, V.; Basko, M. M.; Bedacht, S.; Bläser, C.; Blažević, A.; Busold, S.; Deppert, O.; Ding, J.; Ehret, M.; Fiala, P.; Frydrych, S.; Gericke, D. O.; Hallo, L.; Helfrich, J.; Jahn, D.; Kjartansson, E.; Knetsch, A.; Kraus, D.; Malka, G.; Neumann, N. W.; Pépitone, K.; Pepler, D.; Sander, S.; Schaumann, G.; Schlegel, T.; Schroeter, N.; Schumacher, D.; Seibert, M.; Tauschwitz, An.; Vorberger, J.; Wagner, F.; Weih, S.; Zobus, Y.; Roth, M.
2017-01-01
The energy deposition of ions in dense plasmas is a key process in inertial confinement fusion that determines the α-particle heating expected to trigger a burn wave in the hydrogen pellet and resulting in high thermonuclear gain. However, measurements of ion stopping in plasmas are scarce and mostly restricted to high ion velocities where theory agrees with the data. Here, we report experimental data at low projectile velocities near the Bragg peak, where the stopping force reaches its maximum. This parameter range features the largest theoretical uncertainties and conclusive data are missing until today. The precision of our measurements, combined with a reliable knowledge of the plasma parameters, allows to disprove several standard models for the stopping power for beam velocities typically encountered in inertial fusion. On the other hand, our data support theories that include a detailed treatment of strong ion-electron collisions. PMID:28569766
Is the gut the major source of virus in early simian immunodeficiency virus infection?
Lay, Matthew D H; Petravic, Janka; Gordon, Shari N; Engram, Jessica; Silvestri, Guido; Davenport, Miles P
2009-08-01
The acute phases of human immunodeficiency virus (HIV) and simian immunodeficiency virus (SIV) infection are characterized by rapid and profound depletion of CD4+ T cells from the guts of infected individuals. The large number of CD4+ T cells in the gut (a large fraction of which are activated and express the HIV/SIV coreceptor CCR5), the high level of infection of these cells, and the temporal coincidence of this CD4+ T-cell depletion with the peak of virus in plasma in acute infection suggest that the intestinal mucosa may be the major source of virus driving the peak viral load. Here, we used data on CD4+ T-cell proportions in the lamina propria of the rectums of SIV-infected rhesus macaques (which progress to AIDS) and sooty mangabeys (which do not progress) to show that in both species, the depletion of CD4+ T cells from this mucosal site and its maximum loss rate are often observed several days before the peak in viral load, with few CD4+ T cells remaining in the rectum by the time of peak viral load. In contrast, the maximum loss rate of CD4+ T cells from bronchoalveolar lavage specimens and lymph nodes coincides with the peak in virus. Analysis of the kinetics of depletion suggests that, in both rhesus macaques and sooty mangabeys, CD4+ T cells in the intestinal mucosa are a highly susceptible population for infection but not a major source of plasma virus in acute SIV infection.
Is the Gut the Major Source of Virus in Early Simian Immunodeficiency Virus Infection? ▿
Lay, Matthew D. H.; Petravic, Janka; Gordon, Shari N.; Engram, Jessica; Silvestri, Guido; Davenport, Miles P.
2009-01-01
The acute phases of human immunodeficiency virus (HIV) and simian immunodeficiency virus (SIV) infection are characterized by rapid and profound depletion of CD4+ T cells from the guts of infected individuals. The large number of CD4+ T cells in the gut (a large fraction of which are activated and express the HIV/SIV coreceptor CCR5), the high level of infection of these cells, and the temporal coincidence of this CD4+ T-cell depletion with the peak of virus in plasma in acute infection suggest that the intestinal mucosa may be the major source of virus driving the peak viral load. Here, we used data on CD4+ T-cell proportions in the lamina propria of the rectums of SIV-infected rhesus macaques (which progress to AIDS) and sooty mangabeys (which do not progress) to show that in both species, the depletion of CD4+ T cells from this mucosal site and its maximum loss rate are often observed several days before the peak in viral load, with few CD4+ T cells remaining in the rectum by the time of peak viral load. In contrast, the maximum loss rate of CD4+ T cells from bronchoalveolar lavage specimens and lymph nodes coincides with the peak in virus. Analysis of the kinetics of depletion suggests that, in both rhesus macaques and sooty mangabeys, CD4+ T cells in the intestinal mucosa are a highly susceptible population for infection but not a major source of plasma virus in acute SIV infection. PMID:19458001
NEUTRON SOURCE USING MAGNETIC COMPRESSION OF PLASMA
Quinn, W.E.; Elmore, W.C.; Little, E.M.; Boyer, K.; Tuck, J.L.
1961-10-31
A fusion reactor is described that utilizes compression and heating of an ionized thermonuclear fuel by an externally applied magnetic field, thus avoiding reliance on the pinch effect and its associated instability problems. The device consists of a gas-confining ceramic container surrounded by a single circumferential coil having a shape such as to produce a magnetic mirror geometry. A sinusoidally-oscillating, exponentially-damped current is passed circumferentially around the container, through the coil, inducing a circumferential current in the gas. Maximum compression and plasma temperature are obtained at the peak of the current oscillations, coinciding with maximum magnetic field intensity. Enhanced temperatures are obtained in the second and succeeding half cycles because the thermal energy accumulates from one half cycle to the next. (AEC)
Morgan, L M; Goulder, T J; Tsiolakis, D; Marks, V; Alberti, K G
1979-08-01
Five healthy volunteers and 6 diabetics were given a mixed test meal on two occasions--once with and once without 10 g guar flour. Addition of guar caused a 47% decrease in maximum post-prandial GIP levels, a 48% decrease in blood glucose and a 48% decrease in plasma insulin in normal subjects. In diabetics, addition of guar caused a 30% reduction in maximum post-prandial GIP and 58% decrease in blood glucose. Four normal and 6 diabetic subjects were given a predominantly carbohydrate meal, again with and without 10 g guar. Addition of guar caused a 78% decrease in blood glucose and a 59% decrease in plasma insulin in normal subjects. In diabetics addition of guar caused a 71% decrease in maximum post-prandial plasma GIP and a 68% decrease in blood glucose. Lowering of post-prandial blood glucose, plasma insulin and GIP levels by guar was statistically significant in every case. Addition of guar to the predominantly carbohydrate meal caused a decrease in total plasma GLI in both normal and diabetic subjects but reached statistical significance only in the normal subjects. There was a highly significant correlation (r = 0.83; p less than 0.0005) between peak post-prandial insulin levels in normal subjects and the corresponding plasma GIP concentration. The reduction of GIP or GLI secretion may, therefore, be partly responsible for the smaller rise in plasma insulin observed in normal volunteers when guar is added to meals.
Novel plasma source for safe beryllium spectral line studies in the presence of beryllium dust
NASA Astrophysics Data System (ADS)
Stankov, B. D.; Vinić, M.; Gavrilović Božović, M. R.; Ivković, M.
2018-05-01
Plasma source for beryllium spectral line studies in the presence of beryllium dust particles was realised. The guideline during construction was to prevent exposure to formed dust, considering the toxicity of beryllium. Plasma source characterization through determination of optimal working conditions is described. The necessary conditions for Be spectral line appearance and optimal conditions for line shape measurements are found. It is proven experimentally that under these conditions dust appears coincidently with the second current maximum. The electron density measured after discharge current maximum is determined from the peak separation of the hydrogen Balmer beta spectral line, and the electron temperature is determined from the ratios of the relative intensities of Be spectral lines emitted from successive ionized stages of atoms. Maximum values of electron density and temperature are measured to be 9.3 × 1022 m-3 and 16 800 K, respectively. Construction details and testing of the BeO discharge tube in comparison with SiO2 and Al2O3 discharge tubes are also presented in this paper.
NASA Astrophysics Data System (ADS)
Effenberg, F.; Feng, Y.; Schmitz, O.; Frerichs, H.; Bozhenkov, S. A.; Hölbe, H.; König, R.; Krychowiak, M.; Pedersen, T. Sunn; Reiter, D.; Stephey, L.; W7-X Team
2017-03-01
The results of a first systematic assessment of plasma edge transport processes for the limiter startup configuration at Wendelstein 7-X are presented. This includes an investigation of transport from intrinsic and externally injected impurities and their impact on the power balance and limiter heat fluxes. The fully 3D coupled plasma fluid and kinetic neutral transport Monte Carlo code EMC3-EIRENE is used. The analysis of the magnetic topology shows that the poloidally and toroidally localized limiters cause a 3D helical scrape-off layer (SOL) consisting of magnetic flux tubes of three different connection lengths L C. The transport in the helical SOL is governed by L C as topological scale length for the parallel plasma loss channel to the limiters. A clear modulation of the plasma pressure with L C is seen. The helical flux tube topology results in counter streaming sonic plasma flows. The heterogeneous SOL plasma structure yields an uneven limiter heat load distribution with localized peaking. Assuming spatially constant anomalous transport coefficients, increasing plasma density yields a reduction of the maximum peak heat loads from 12 MWm-2 to 7.5 MWm-2 and a broadening of the deposited heat fluxes. The impact of impurities on the limiter heat loads is studied by assuming intrinsic carbon impurities eroded from the limiter surfaces with a gross chemical sputtering yield of 2 % . The resulting radiative losses account for less than 10% of the input power in the power balance with marginal impact on the limiter heat loads. It is shown that a significant mitigation of peak heat loads, 40-50%, can be achieved with controlled impurity seeding with nitrogen and neon, which is a method of particular interest for the later island divertor phase.
Paracetamol plasma and cerebrospinal fluid pharmacokinetics in children
Anderson, B J; Holford, N H G; Woollard, G A; Chan, P L S
1998-01-01
Aims Paracetamol has a central action for both antipyresis and analgesia. Maximum temperature decrease and peak analgesia are reported at 1–2 h after peak plasma paracetamol concentration. We wished to determine the relationship between plasma and cerebrospinal fluid (CSF) pharmacokinetics in children. Methods Concentration-time profiles in plasma and CSF after nasogastric paracetamol 40 mg kg−1 were measured in nine children who had indwelling ventricular drains. Estimation of population pharmacokinetic parameters was made using both a standard two-stage population approach (MKMODEL) and a nonlinear mixed effect model (NONMEM). Results were standardized to a 70 kg person using an allometric power model. Results Both approaches gave similar estimates. NONMEM parameter estimates were clearance 10.2 l h−1 (CV 47%), volume of distribution 67.1 l (CV 58%) and absorption rate constant 0.77 h−1 (CV 49%). Cerebrospinal fluid concentrations lagged behind those of plasma. The equilibration half time was 0.72 h (CV 117%). The CSF/plasma partition coefficient was 1.18 (CV 8%). Conclusions Higher concentrations in the CSF probably reflect the lower free water volume of plasma. The CSF equilibration half time suggests that CSF kinetics approximate more closely to the effect compartment than plasma, but further time is required for paracetamol to exert its effects. Effect site concentrations equilibrate slowly with plasma. Paracetamol should be given 1–2 h before anticipated pain or fever in children. PMID:9764964
Dynamics of low- and high-Z metal ions emitted during nanosecond laser-produced plasmas
NASA Astrophysics Data System (ADS)
Elsied, Ahmed M.; Diwakar, Prasoon K.; Polek, Mathew; Hassanein, Ahmed
2016-11-01
Dynamics of metal ions during laser-produced plasmas was studied. A 1064 nm, Nd: YAG laser pulse was used to ablate pure Al, Fe, Co, Mo, and Sn samples. Ion flux and velocity were measured using Faraday cup ion collector. Time-of-flight measurements showed decreasing ion flux and ion velocity with increasing atomic weight, and heavy metal ion flux profile exhibited multiple peaks that was not observed in lighter metals. Slow peak was found to follow shifted Maxwell Boltzmann distribution, while the fast peak was found to follow Gaussian distribution. Ion flux angular distribution that was carried out on Mo and Al using fixed laser intensity 2.5 × 1010 W/cm2 revealed that the slow ion flux peaks at small angles, that is, close to normal to the target ˜0° independent of target's atomic weight, and fast ion flux for Mo peaks at large angles ˜40° measured from the target normal, while it completely absents for Al. This difference in spatial and temporal distribution reveals that the emission mechanism of the fast and slow ions is different. From the slow ion flux angular distribution, the measured plume expansion ratio (plume forward peaking) was 1.90 and 2.10 for Al and Mo, respectively. Moreover, the effect of incident laser intensity on the ion flux emission as well as the emitted ion velocity were investigated using laser intensities varying from 2.5 × 1010 W/cm2 to 1.0 × 1011 W/cm2. Linear increase of fast ion flux and velocity, and quadratic increase of slow ion flux and velocity were observed. For further understanding of plume dynamics, laser optical emission spectroscopy was used to characterize Sn plasma by measuring the temporal and spatial evolution of plasma electron density Ne and electron temperature Te. At 3.5 mm away from the target, plasma density showed slow decrease with time, however electron temperature was observed to decrease dramatically. The maximum plasma density and temperature occurred at 0.5 mm away from target and were measured to be 8.0 × 1017 cm-3 and 1.3 eV, respectively.
Plasma bullet current measurements in a free-stream helium capillary jet
NASA Astrophysics Data System (ADS)
Oh, Jun-Seok; Walsh, James L.; Bradley, James W.
2012-06-01
A commercial current monitor has been used to measure the current associated with plasma bullets created in both the positive and negative half cycles of the sinusoidal driving voltage sustaining a plasma jet. The maximum values of the positive bullet current are typically ˜750 µA and persist for 10 µs, while the peaks in the negative current of several hundred μA are broad, persisting for about 40 µs. From the time delay of the current peaks with increasing distance from the jet nozzle, an average bullet propagation speed has been measured; the positive and negative bullets travel at 17.5 km s-1 and 3.9 km s-1 respectively. The net space charge associated with the bullet(s) has also been calculated; the positive and negative bullets contain a similar net charge of the order of 10-9 C measured at all monitor positions, with estimated charged particle densities nb of ˜1010-1011 cm-3 in the bullet.
9 GeV energy gain in a beam-driven plasma wakefield accelerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Litos, M.; Adli, E.; Allen, J. M.
2016-02-15
An electron beam has gained a maximum energy of 9 GeV per particle in a 1.3 m-long electron beam-driven plasma wakefield accelerator. The amount of charge accelerated in the spectral peak was 28.3 pC, and the root-mean-square energy spread was 5.0%. The mean accelerated charge and energy gain per particle of the 215 shot data set was 115 pC and 5.3 GeV, respectively, corresponding to an acceleration gradient of 4.0 GeV m -1 at the spectral peak. Moreover, the mean energy spread of the data set was 5.1%. Our results are consistent with the extrapolation of the previously reported energymore » gain results using a shorter, 36 cm-long plasma source to within 10%, evincing a non-evolving wake structure that can propagate distances of over a meter in length. Wake-loading effects were evident in the data through strong dependencies observed between various spectral properties and the amount of accelerated charge.« less
NASA Astrophysics Data System (ADS)
Hwang, Ju Hyun; Lee, Hyun Jun; Shim, Yong Sub; Park, Cheol Hwee; Jung, Sun-Gyu; Kim, Kyu Nyun; Park, Young Wook; Ju, Byeong-Kwon
2015-01-01
Extremely low-haze light extraction from organic light-emitting diodes (OLEDs) was achieved by utilizing nanoscale corrugation, which was simply fabricated with plasma treatment and sonication. The haze of the nanoscale corrugation for light extraction (NCLE) corresponds to 0.21% for visible wavelengths, which is comparable to that of bare glass. The OLEDs with NCLE showed enhancements of 34.19% in current efficiency and 35.75% in power efficiency. Furthermore, the OLEDs with NCLE exhibited angle-stable electroluminescence (EL) spectra for different viewing angles, with no change in the full width at half maximum (FWHM) and peak wavelength. The flexibility of the polymer used for the NCLE and plasma treatment process indicates that the NCLE can be applied to large and flexible OLED displays.Extremely low-haze light extraction from organic light-emitting diodes (OLEDs) was achieved by utilizing nanoscale corrugation, which was simply fabricated with plasma treatment and sonication. The haze of the nanoscale corrugation for light extraction (NCLE) corresponds to 0.21% for visible wavelengths, which is comparable to that of bare glass. The OLEDs with NCLE showed enhancements of 34.19% in current efficiency and 35.75% in power efficiency. Furthermore, the OLEDs with NCLE exhibited angle-stable electroluminescence (EL) spectra for different viewing angles, with no change in the full width at half maximum (FWHM) and peak wavelength. The flexibility of the polymer used for the NCLE and plasma treatment process indicates that the NCLE can be applied to large and flexible OLED displays. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr06547f
Yasumura, R; Kobayashi, Y; Ochiai, R
2016-05-01
Levobupivacaine is commonly used as the local anaesthetic of choice in peripheral nerve blocks, but its pharmacokinetics have not been fully investigated. We compared the changes in plasma concentrations of levobupivacaine following transversus abdominis plane block and rectus sheath block. Fifty woman undergoing laparoscopy were randomly allocated to receive either a transversus abdominis plane block or an rectus sheath block. In both groups, 2.5 mg.kg(-1) levobupivacaine was administered, and blood samples were obtained 15 min, 30 min, 60 min and 120 min after injection. The mean maximum plasma concentration (Cmax) and mean time to reach Cmax (Tmax) as determined by non-linear regression analysis were 1.05 μg.ml(-1) and 32.4 min in the transversus abdominis plane group and 0.95 μg.ml(-1) and 60.9 min in the rectus sheath group, respectively. The plasma concentration of levobupivacaine peaked earlier in the transversus abdominis plane group than in the rectus sheath group and the maximum plasma concentration depended on the dose administered but not the procedure. © 2016 The Association of Anaesthetists of Great Britain and Ireland.
Dynamical resonance shift and unification of resonances in short-pulse laser-cluster interaction
NASA Astrophysics Data System (ADS)
Mahalik, S. S.; Kundu, M.
2018-06-01
Pronounced maximum absorption of laser light irradiating a rare-gas or metal cluster is widely expected during the linear resonance (LR) when Mie-plasma wavelength λM of electrons equals the laser wavelength λ . On the contrary, by performing molecular dynamics (MD) simulations of an argon cluster irradiated by short 5-fs (FWHM) laser pulses it is revealed that, for a given laser pulse energy and a cluster, at each peak intensity there exists a λ —shifted from the expected λM—that corresponds to a unified dynamical LR at which evolution of the cluster happens through very efficient unification of possible resonances in various stages, including (i) the LR in the initial time of plasma creation, (ii) the LR in the Coulomb expanding phase in the later time, and (iii) anharmonic resonance in the marginally overdense regime for a relatively longer pulse duration, leading to maximum laser absorption accompanied by maximum removal of electrons from cluster and also maximum allowed average charge states for the argon cluster. Increasing the laser intensity, the absorption maxima is found to shift to a higher wavelength in the band of λ ≈(1 -1.5 ) λM than permanently staying at the expected λM. A naive rigid sphere model also corroborates the wavelength shift of the absorption peak as found in MD and unequivocally proves that maximum laser absorption in a cluster happens at a shifted λ in the marginally overdense regime of λ ≈(1 -1.5 ) λM instead of λM of LR. The present study is important for guiding an optimal condition laser-cluster interaction experiment in the short-pulse regime.
Envelope matching for enhanced backward Raman amplification by using self-ionizing plasmas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Z. M.; Zhang, B.; Hong, W.
2014-12-15
Backward Raman amplification (BRA) in plasmas has been promoted as a means for generating ultrapowerful laser pulses. For the purpose of achieving the maximum intensities over the shortest distances, an envelope matching between the seed pulse and the amplification gain is required, i.e., the seed pulse propagates at the same velocity with the gain such that the peak of the seed pulse can always enjoy the maximum gain. However, such an envelope matching is absent in traditional BRA because in the latter the amplification gain propagates at superluminous velocity while the seed pulse propagates at the group velocity, which ismore » less than the speed of light. It is shown here that, by using self-ionizing plasmas, the speed of the amplification gain can be well reduced to reach the envelope matching regime. This results in a favorable BRA process, in which higher saturated intensity, shorter interaction length and higher energy-transfer efficiency are achieved.« less
Performance of a green propellant thruster with discharge plasma
NASA Astrophysics Data System (ADS)
Shindo, Takahiro; Wada, Asato; Maeda, Hiroshi; Watanabe, Hiroki; Takegahara, Haruki
2017-02-01
A discharge plasma was applied to initiate the combustion of a hydroxylammonium nitrate-based propellant as a substitute for the catalysts that are typically employed. The resulting thrust and thrust-to-power ratio during short interval firing tests as well as the chamber pressure with a single pulse discharge were evaluated. A 1.5-s firing test generated a maximum thrust of 322 mN along with a thrust-to-power ratio of 0.95 mN/W. During the single-pulse discharge trials, pulsed discharge capacitor energies of 5.4, 10.8, and 16.4 J were assessed, and the maximum chamber pressure was found to increase as the energy was raised. The maximum chamber pressures varied widely between experimental trials, and a 16.4-J energy value resulted in the highest chamber pressure of over 1 MPaG. The time spans between the pulsed discharge and the peak chamber pressure were in the range of 1-2 ms, representing a chamber pressure increase rate much higher than those obtained with standard catalysts.
Low-latitude zonal and vertical ion drifts seen by DE 2
NASA Technical Reports Server (NTRS)
Coley, W. R.; Heelis, R. A.
1989-01-01
Horizontal and vertical ion drift data from the DE 2 spacecraft have been used to determine average zonal and vertical plasma flow (electric field) characteristics in the +/- 26-deg dip latitude region during a time of high solar activity. The 'average data' local time profile for an apex height bin centered at 400 km indicates westward plasma flow from 0600 to 1900 solar local time ((SLT) with a maximum westward velocity of 80 m/s in the early afternoon. There is a sharp change to eastward flow at approximately 1900 hours with an early evening peak of 170 m/s. A secondary nighttime maximum exists at 0430 SLT preceeding the reversal to westward flow. This profile is in good agreement with Jicamarca, Peru, radar measurements made under similar solar maximum conditions. Haramonic analysis indicates a net superrotation which is strongest at lower apex altitudes. The diurnal term is dominant, but higher order terms through the quatradiurnal are significant.
Variations in Solar Parameters and Cosmic Rays with Solar Magnetic Polarity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oh, S.; Yi, Y., E-mail: suyeonoh@jnu.ac.kr
The sunspot number varies with the 11-year Schwabe cycle, and the solar magnetic polarity reverses every 11 years approximately at the solar maximum. Because of polarity reversal, the difference between odd and even solar cycles is seen in solar activity. In this study, we create the mean solar cycle expressed by phase using the monthly sunspot number for all solar cycles 1–23. We also generate the mean solar cycle for sunspot area, solar radio flux, and cosmic ray flux within the allowance of observational range. The mean solar cycle has one large peak at solar maximum for odd solar cyclesmore » and two small peaks for most even solar cycles. The odd and even solar cycles have the statistical difference in value and shape at a confidence level of at least 98%. For solar cycles 19–23, the second peak in the even solar cycle is larger than the first peak. This result is consistent with the frequent solar events during the declining phase after the solar maximum. The difference between odd and even solar cycles can be explained by a combined model of polarity reversal and solar rotation. In the positive/negative polarity, the polar magnetic field introduces angular momentum in the same/opposite direction as/to the solar rotation. Thus the addition/subtraction of angular momentum can increase/decrease the motion of plasma to support the formation of sunspots. Since the polarity reverses at the solar maximum, the opposite phenomenon occurs in the declining phase.« less
ICRH system performance during ITER-Like Wall operations at JET and the outlook for DT campaign
NASA Astrophysics Data System (ADS)
Monakhov, Igor; Blackman, Trevor; Dumortier, Pierre; Durodié, Frederic; Jacquet, Philippe; Lerche, Ernesto; Noble, Craig
2017-10-01
Performance of JET ICRH system since installation of the metal ITER-Like Wall (ILW) has been assessed statistically. The data demonstrate steady increase of the RF power coupled to plasmas over recent years with the maximum pulse-average and peak values exceeding respectively 6MW and 8MW in 2016. Analysis and extrapolation of power capabilities of conventional JET ICRH antennas is provided and key performance-limiting factors are discussed. The RF plant operational frequency options are presented highlighting the issues of efficient ICRH application within a foreseeable range of DT plasma scenarios.
Li, An; Guo, Shuai; Wazir, Nasrullah; Chai, Ke; Liang, Liang; Zhang, Min; Hao, Yan; Nan, Pengfei; Liu, Ruibin
2017-10-30
The inevitable problems in laser induced breakdown spectroscopy are matrix effect and statistical fluctuation of the spectral signal, which can be partly avoided by utilizing a proper confined unit. The dependences of spectral signal enhancement on relative permittivity were studied by varying materials to confine the plasma, which include polytetrafluoroethylene(PTFE), nylon/dacron, silicagel, and nitrile-butadiene rubber (NBR) with the relative permittivity 2.2, ~3.3, 3.6, 8~13, 15~22. We found that higher relative permittivity rings induce stronger enhancement ability, which restricts the energy dissipation of plasma better and due to the reflected electromagnetic wave from the wall of different materials, the electromagnetic field of plasma can be well confined and makes the distribution of plasma more orderly. The spectral intensities of the characteristic lines Si I 243.5 nm and Si I 263.1 nm increased approximately 2 times with relative permittivity values from 2.2 to ~20. The size dependent enhancement of PTFE was further checked and the maximum gain was realized by using a confinement ring with a diameter size of 5 mm and a height of 3 mm (D5mmH3mm), and the rings with D2mmH1mm and D3mmH2mm also show higher enhancement factor. In view of peak shift, peak lost and accidental peaks in the obtained spectra were properly treated in data progressing; the spectral fluctuation decreased drastically for various materials with different relative permittivities as confined units, which means the core of plasma is stabilized, attributing to the confinement effect. Furthermore, the quantitative analysis in coal shows wonderful results-the prediction fitting coefficient R 2 reaches 0.98 for ash and 0.99 for both volatile and carbon.
Variations in plasma wave intensity with distance along the electron foreshock boundary at Venus
NASA Technical Reports Server (NTRS)
Crawford, G. K.; Strangeway, R. J.; Russell, C. T.
1991-01-01
Plasma waves are observed in the solar wind upstream of the Venus bow shock by the Pioneer Venus Orbiter. These wave signatures occur during periods when the interplanetary magnetic field through the spacecraft position intersects the bow shock, thereby placing the spacecraft in the foreshock region. Wave intensity is analyzed as a function of distance along the electron foreshock boundary. It is found that the peak wave intensity may increase along the foreshock boundary from the tangent point to a maximum value at several Venus radii, then decrease in intensity with subsequent increase in distance. These observations could be associated with the instability process: the instability of the distribution function increasing with distance from the tangent point to saturation at the peak. Thermalization of the beam for distances beyond this point could reduce the distribution function instability resulting in weaker wave signatures.
Baker, Paul A; Goodloe, David R; Vohra, Yogesh K
2017-11-14
The purpose of this study is to understand the basic mechanisms responsible for the synthesis of nanostructured diamond films in a microwave plasma chemical vapor deposition (MPCVD) process and to identify plasma chemistry suitable for controlling the morphology and electrical properties of deposited films. The nanostructured diamond films were synthesized by MPCVD on Ti-6Al-4V alloy substrates using H₂/CH₄/N₂ precursor gases and the plasma chemistry was monitored by the optical emission spectroscopy (OES). The synthesized thin-films were characterized by x -ray diffraction and scanning electron microscopy. The addition of B₂H₆ to the feedgas during MPCVD of diamond thin-films changes the crystal grain size from nanometer to micron scale. Nanostructured diamond films grown with H₂/CH₄/N₂ gases demonstrate a broad (111) Bragg x -ray diffraction peak (Full-Width at Half-Maximum (FWHM) = 0.93° 2θ), indicating a small grain size, whereas scans show a definite sharpening of the diamond (111) peak (FWHM = 0.30° 2θ) with the addition of boron. OES showed a decrease in CN (carbon-nitrogen) radical in the plasma with B₂H₆ addition to the gas mixture. Our study indicates that CN radical plays a critical role in the synthesis of nanostructured diamond films and suppression of CN radical by boron-addition in the plasma causes a morphological transition to microcrystalline diamond.
Dragun, Zrinka; Krasnići, Nesrete; Kolar, Nicol; Filipović Marijić, Vlatka; Ivanković, Dušica; Erk, Marijana
2018-05-15
Cytosolic distributions of nonessential metals Cd and Tl and seven essential elements among compounds of different molecular masses were studied in the liver of brown trout (Salmo trutta) from the karstic Krka River in Croatia. Analyses were done by size exclusion high performance liquid chromatography and high resolution inductively coupled plasma mass spectrometry. Common feature of Cd and Tl, as highly toxic elements, was their distribution within only two narrow peaks. The increase of cytosolic Cd concentrations was reflected in marked increase of Cd elution within low molecular mass peak (maximum at ∼15 kDa), presumably containing metallothioneins (MTs), which indicated successful Cd detoxification in brown trout liver under studied exposure conditions. Contrary, the increase of cytosolic Tl concentrations was reflected in marked increase of Tl elution within high molecular mass peak (maximum at 140 kDa), which probably indicated incomplete Tl detoxification. Common feature of the majority of studied essential elements was their distribution within more peaks, often broad and not well resolved, which is consistent with their numerous physiological functions. Among observed associations of essential metals/nonmetal to proteins, the following could be singled out: Cu and Zn association to MTs, Fe association to storage protein ferritin, and Se association to compounds of very low molecular masses (<5 kDa). The obtained results present the first step towards identification of metal-binding compounds in hepatic cytosol of brown trout, and thus a significant contribution to better understanding of metal fate in the liver of that important bioindicator species. Copyright © 2018 Elsevier Ltd. All rights reserved.
Plasma waves downstream of weak collisionless shocks
NASA Technical Reports Server (NTRS)
Coroniti, F. V.; Greenstadt, E. W.; Moses, S. L.; Smith, E. J.; Tsurutani, B. T.
1993-01-01
In September 1983 the International Sun Earth Explorer 3 (ISEE 3) International Cometary Explorer (ICE) spacecraft made a long traversal of the distant dawnside flank region of the Earth's magnetosphere and had many encounters with the low Mach number bow shock. These weak shocks excite plasma wave electric field turbulence with amplitudes comparable to those detected in the much stronger bow shock near the nose region. Downstream of quasi-perpendicular (quasi-parallel) shocks, the E field spectra exhibit a strong peak (plateau) at midfrequencies (1 - 3 kHz); the plateau shape is produced by a low-frequency (100 - 300 Hz) emission which is more intense behind downstream of two quasi-perpendicular shocks show that the low frequency signals are polarized parallel to the magnetic field, whereas the midfrequency emissions are unpolarized or only weakly polarized. A new high frequency (10 - 30 kHz) emission which is above the maximum Doppler shift exhibit a distinct peak at high frequencies; this peak is often blurred by the large amplitude fluctuations of the midfrequency waves. The high-frequency component is strongly polarized along the magnetic field and varies independently of the lower-frequency waves.
NASA Astrophysics Data System (ADS)
Gebhart, Trey; Baylor, Larry; Winfrey, Leigh
2016-10-01
The realization of fusion energy requires materials that can withstand high heat and particle fluxes at the plasma material interface. In this work, an electrothermal (ET) plasma source has been designed as a possible transient heat flux source for a linear plasma material interaction device. An ET plasma source operates in the ablative arc regime, which is driven by a DC capacitive discharge. The current travels through the 4mm bore of a boron nitride liner and subsequently ablates and ionizes the liner material. This results in a high density plasma with a large unidirectional bulk flow out of the source exit. The pulse length for the ET source has been optimized using a pulse forming network to have a duration of 1ms at full-width half maximum. The peak currents and maximum source energies seen in this system are 2kA and 5kJ. The goal of this work is to show that the ET source produces electron densities and heat fluxes that are comparable to transient events in future large magnetic confinement fusion devices. Heat flux, plasma temperature, and plasma density were determined for each test shot using infrared imaging and optical spectroscopy techniques. This work will compare the ET source output (heat flux, temperature, and density) with and without an applied magnetic field. Research sponsored by the Laboratory Directed Research and Development Program of Oak Ridge National Laboratory, managed by UT-Battelle, LLC, for the U. S. Department of Energy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takino, Hideo; Shibata, Norio; Itoh, Hiroshi
2006-08-10
We have developed plasma chemical vaporization machining by using a microelectrode for the fabrication of small complex-shaped optical surfaces. In this method, a0.5 mm diameter pipe microelectrode, from which processing gas is drawn in, generates a small localized plasma that is scanned over a work piece under numerical computer control to shape a desired surface. A12 mmx12 mm nonaxisymmetric mirror with a maximum depth of approximately 3 {mu}m was successfully fabricated with a peak-to-valley shape accuracy of 0.04 {mu}m in an area excluding the edges of the mirror. The average surface roughness was 0.58 nm, which is smooth enough formore » optical use.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sakai, Y.; Kumai, H.; Nakanishi, Y.
2013-02-15
The emission spectra of hydrogen-like nitrogen Balmer at the wavelength of 13.4 nm in capillary Z-pinch discharge plasma are experimentally examined. Ionization to fully strip nitrogen at the pinch maximum, and subsequent rapid expansion cooling are required to establish the population inversion between the principal quantum number of n = 2 and n = 3. The ionization and recombination processes with estimated plasma parameters are evaluated by utilizing a time integrated spectrum pinhole image containing radial spatial information. A cylindrical capillary plasma is pinched by a triangular pulsed current with peak amplitude of 50 kA and pulse width of 50more » ns.« less
Experimental characterization of a coaxial plasma accelerator for a colliding plasma experiment
NASA Astrophysics Data System (ADS)
Wiechula, J.; Hock, C.; Iberler, M.; Manegold, T.; Schönlein, A.; Jacoby, J.
2015-04-01
We report experimental results of a single coaxial plasma accelerator in preparation for a colliding plasma experiment. The utilized device consisted of a coaxial pair of electrodes, accelerating the plasma due to J ×B forces. A pulse forming network, composed of three capacitors connected in parallel, with a total capacitance of 27 μF was set up. A thyratron allowed to switch the maximum applied voltage of 9 kV. Under these conditions, the pulsed currents reached peak values of about 103 kA. The measurements were performed in a small vacuum chamber with a neutral-gas prefill at gas pressures between 10 Pa and 14 000 Pa. A gas mixture of ArH2 with 2.8% H2 served as the discharge medium. H2 was chosen in order to observe the broadening of the Hβ emission line and thus estimate the electron density. The electron density for a single plasma accelerator reached peak values on the order of 1016 cm-3 . Electrical parameters, inter alia inductance and resistance, were determined for the LCR circuit during the plasma acceleration as well as in a short circuit case. Depending on the applied voltage, the inductance and resistance reached values ranging from 194 nH to 216 nH and 13 mΩ to 23 mΩ, respectively. Furthermore, the plasma velocity was measured using a fast CCD camera. Plasma velocities of 2 km/s up to 17 km/s were observed, the magnitude being highly correlated with gas pressure and applied voltage.
Finite Gyroradius Effects Observed in Pickup Oxygen Ions at Venus
NASA Technical Reports Server (NTRS)
Hartle, Richard E.; Intriligator, Devrie; Grebowsky, Joseph M.; Einaudi, Franco (Technical Monitor)
2000-01-01
On the dayside of Venus, the hot oxygen corona extending above the ionopause is the principal source of pickup oxygen ions. The ions are born here and picked up by the ionosheath plasma as it is deflected around the planet. These pickup ions have been observed by the Orbiter Plasma Analyzer (OPA) throughout the Pioneer Venus Orbiter (PVO) mission. They were observed over a region extending from their dayside source to great distances downstream (about 10 Venus radii), in the solar wind wake, as PVO passed through apoapsis. Finite gyroradius effects in the velocity distribution of the oxygen pickup ions are expected in the source region because the gyroradius is several times larger than the scale height of the hot oxygen source. Such effects are also expected in those regions of the ionosheath where the scale lengths of the magnetic field and the ambient plasma velocity field are less than the pickup ion gyroradius. While explicitly accounting for the spatial distribution of the hot oxygen source, an analytic expression for the pickup oxygen ion velocity distribution is developed to study how it is affected by finite gyroradii. The analysis demonstrates that as the gyroradius increases by factors of three to six above the hot oxygen scale height, the peak of the pickup oxygen ion flux distribution decreases 25 to 50% below the maximum allowed speed, which is twice the speed of the ambient plasma times the sine of the angle between the magnetic field and the flow velocity. The pickup oxygen ion flux distribution observed by OPA is shown to follow this behavior in the source region. It is also shown that this result is consistent with the pickup ion distributions observed in the wake, downstream of the source, where the flux peaks are usually well below the maximum allowed speed.
B{sub 4}C protective coating under irradiation by QSPA-T intensive plasma fluxes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buzhinskij, O. I.; Barsuk, V. A.; Begrambekov, L. B., E-mail: lbb@plasma.mephi.ru
The effect of the QSPA-T pulsed plasma irradiation on the crystalline boron carbide B{sub 4}C coating was examined. The duration of the rectangular plasma pulses was 0.5 ms with an interval of 5–10 min between pulses. The maximum power density in the central part of plasma stream was 1 GW/m{sup 2}. The coating thickness varied from 20 to 40 μm on different surface areas. Modification of the surface layers and transformation of the coating at elevated temperature under plasma pulse irradiation during four successive series of impulses are described. It is shown that the boron carbide coating withstood the fullmore » cycle of tests under irradiation with 100 plasma pulses with peak power density of 1GW/m{sup 2}. Constitutive surface deterioration was not detected and the boron carbide coating kept crystal structure B{sub 4}C throughout the irradiation zone at the surface depth no less 2 μm.« less
Creely, A J; Ida, K; Yoshinuma, M; Tokuzawa, T; Tsujimura, T; Akiyama, T; Sakamoto, R; Emoto, M; Tanaka, K; Michael, C A
2017-07-01
A new method for measuring density fluctuation profiles near the edge of plasmas in the Large Helical Device (LHD) has been developed utilizing reflectometry combined with pellet-induced fast density scans. Reflectometer cutoff location was calculated by proportionally scaling the cutoff location calculated with fast far infrared laser interferometer (FIR) density profiles to match the slower time resolution results of the ray-tracing code LHD-GAUSS. Plasma velocity profile peaks generated with this reflectometer mapping were checked against velocity measurements made with charge exchange spectroscopy (CXS) and were found to agree within experimental uncertainty once diagnostic differences were accounted for. Measured density fluctuation profiles were found to peak strongly near the edge of the plasma, as is the case in most tokamaks. These measurements can be used in the future to inform inversion methods of phase contrast imaging (PCI) measurements. This result was confirmed with both a fixed frequency reflectometer and calibrated data from a multi-frequency comb reflectometer, and this method was applied successfully to a series of discharges. The full width at half maximum of the turbulence layer near the edge of the plasma was found to be only 1.5-3 cm on a series of LHD discharges, less than 5% of the normalized minor radius.
NASA Astrophysics Data System (ADS)
Creely, A. J.; Ida, K.; Yoshinuma, M.; Tokuzawa, T.; Tsujimura, T.; Akiyama, T.; Sakamoto, R.; Emoto, M.; Tanaka, K.; Michael, C. A.
2017-07-01
A new method for measuring density fluctuation profiles near the edge of plasmas in the Large Helical Device (LHD) has been developed utilizing reflectometry combined with pellet-induced fast density scans. Reflectometer cutoff location was calculated by proportionally scaling the cutoff location calculated with fast far infrared laser interferometer (FIR) density profiles to match the slower time resolution results of the ray-tracing code LHD-GAUSS. Plasma velocity profile peaks generated with this reflectometer mapping were checked against velocity measurements made with charge exchange spectroscopy (CXS) and were found to agree within experimental uncertainty once diagnostic differences were accounted for. Measured density fluctuation profiles were found to peak strongly near the edge of the plasma, as is the case in most tokamaks. These measurements can be used in the future to inform inversion methods of phase contrast imaging (PCI) measurements. This result was confirmed with both a fixed frequency reflectometer and calibrated data from a multi-frequency comb reflectometer, and this method was applied successfully to a series of discharges. The full width at half maximum of the turbulence layer near the edge of the plasma was found to be only 1.5-3 cm on a series of LHD discharges, less than 5% of the normalized minor radius.
Fairfax, A J; Rehahn, M; Jones, D; O'Malley, B
1984-01-01
The time course of changes in plasma cyclic AMP, heart rate and bronchial tone after inhalation of fenoterol or isoprenaline from a dose-metered aerosol are reported in a group of normal subjects. After isoprenaline, plasma cyclic AMP increased rapidly reaching a peak by 10 min and returned to basal levels within 60 min. A rapid, transient rise in heart rate occurred that was maximal by 5 min and returned to a basal level by 45 min. After fenoterol, the changes in cyclic AMP and heart rate were of much longer duration. The rise in plasma cyclic AMP was slower in onset and of greater magnitude than for isoprenaline, reaching a peak by 20 min and remaining above basal level for more than 6 h. The maximum increase in heart rate after fenoterol was less than that observed with isoprenaline but an elevated rate persisted for 4 h after inhalation of fenoterol. Fenoterol is known to have a longer duration of action as a bronchodilator in comparison with isoprenaline. The prolonged rise in plasma cyclic AMP in normal subjects given inhaled fenoterol may reflect this long duration of action. The concomitant rise in heart rate, however, suggests that the duration of plasma cyclic AMP response may in part be due to the systemic effect of the fraction of inhaled fenoterol known to be absorbed via the buccal and intestinal routes. PMID:6322828
Studies on the absorption and disposition of meptazinol following rectal administration.
Franklin, R A; Southgate, P J; Coleman, A J
1977-01-01
1 Rectal administration of the new analgesic drug, meptazinol, resulted in rapid absorption of the compound both in the monkey and in man. Peak plasma levels were observed within 0.5 h of dosing. 2 Absorption of the drug following rectal administration was extensive as shown by the recovery of 65-90% of the dose in the urine. 3 Despite substantial inter-individual variation in the observed maximum plasma concentrations of the drug, it was still evident that concentrations after rectal dosage were considerably higher than when the same dosage was given orally. 4 Elimination of the drug from plasma took place rapidly in an apparently mono-exponential manner in both species. The half-life of elimination in monkeys was 1.25 h and in man 2.0 h. PMID:405029
RF wave observations in beam-plasma discharge
NASA Technical Reports Server (NTRS)
Bernstein, W.
1986-01-01
The Beam Plasma Discharge (BPD) was produced in the large vacuum chamber at Johnson Space Center (20 x 30 m) using an energetic electron beam of moderately high perveance. A more complete expression of the threshold current I sub c taking into account the pitch angle injection dependence is given. Ambient plasma density inferred from wave measurements under various beam conditions are reported. Maximum frequency of the excited RF band behaves differently than the frequency of the peak amplitude. The latter shows signs of parabolic saturation consistent with the light data. Beam plasma state (pre-BPD or BPD) does not affect the pitch angle dependence. Unexpected strong modulation of the RF spectrum at half odd integer of the electron cyclotron frequency (n + 1/2)f sub ce is reported (5 n 10). Another new feature, the presence of wave emission around 3/2 f sub ce for I sub b is approximate I sub c is reported.
Postprandial glucose response to selected tropical fruits in normal glucose-tolerant Nigerians.
Edo, A; Eregie, A; Adediran, O; Ohwovoriole, A; Ebengho, S
2011-01-01
The glycemic response to commonly eaten fruits in Nigeria has not been reported. Therefore, this study assessed the plasma glucose response to selected fruits in Nigeria. Ten normal glucose-tolerant subjects randomly consumed 50 g carbohydrate portions of three fruits: banana (Musa paradisiaca), pineapple (Ananus comosus), and pawpaw (Carica papaya), and a 50-g glucose load at 1-week intervals. Blood samples were collected in the fasting state and half-hourly over a 2-h period post-ingestion of the fruits or glucose. The samples were analyzed for plasma glucose concentrations. Plasma glucose responses were assessed by the peak plasma glucose concentration, maximum increase in plasma glucose, 2-h postprandial plasma glucose level, and incremental area under the glucose curve and glycemic index (GI). The results showed that the blood glucose response to these three fruits was similar in terms of their incremental areas under the glucose curve, maximum increase in plasma glucose, and glycemic indices (GIs). The 2-h postprandial plasma glucose level of banana was significantly higher than that of pineapple, P < 0.025. The mean ± SEM GI values were as follows: pawpaw; 86 ± 26.8%; banana, 75.1 ± 21.8%; pineapple, 64.5 ± 11.3%. The GI of glucose is taken as 100. The GI of pineapple was significantly lower than that of glucose (P < 0.05). Banana, pawpaw, and pineapple produced a similar postprandial glucose response. Measured portions of these fruits may be used as fruit exchanges with pineapple having the most favorable glycemic response.
NASA Astrophysics Data System (ADS)
Baitha, Anuj Ram; Kumar, Ashwani; Bhattacharjee, Sudeep
2018-02-01
We report a table top experiment to investigate production and properties of a plasma confined by a dipole magnet. A water cooled, strong, cylindrical permanent magnet (NdFeB) magnetized along the axial direction and having a surface magnetic field of ˜0.5 T is employed to create a dipole magnetic field. The plasma is created by electron cyclotron resonance heating. Visual observations of the plasma indicate that radiation belts appear due to trapped particles, similar to the earth's magnetosphere. The electron temperature lies in the range 2-13 eV and is hotter near the magnets and in a downstream region. It is found that the plasma (ion) density reaches a value close to 2 × 1011 cm-3 and peaks at a radial distance about 3 cm from the magnet. The plasma beta β (β = plasma pressure/magnetic pressure) increases radially outward, and the maximum β for the present experimental system is ˜2%. It is also found that the singly charged ions are dominant in the discharge.
Electron energy distributions measured during electron beam/plasma interactions. [in E region
NASA Technical Reports Server (NTRS)
Jost, R. J.; Anderson, H. R.; Mcgarity, J. O.
1980-01-01
In the large vacuum facility at the NASA-Johnson Space Center an electron beam was projected 20 m parallel to B from a gun with variable accelerating potential (1.0 to 2.5 kV) to an aluminum target. The ionospheric neutral pressure and field were approximated. Beam electron energy distributions were measured directly using an electrostatic deflection analyzer and indirectly with a detector that responded to the X-rays produced by electron impact on the target. At low currents the distribution is sharply peaked at the acceleration potential. At high currents a beam plasma discharge occurs and electrons are redistributed in energy so that the former energy peak broadens to 10-15 percent FWHM with a strongly enhanced low energy tail. At the 10% of maximum point the energy spectrum ranges from less than 1/2 to 1.2 times the gun energy. The effect is qualitatively the same at all pitch angles and locations sampled.
Xu, Yongjiang; Wang, Bin; Liu, Xuezhou; Shi, Bao; Zang, Kun
2017-04-01
Although gonadotrophins are major regulators of ovarian function in teleosts and other vertebrates, accumulating evidence indicates that the growth hormone (GH)-insulin-like growth factor (IGF) axis also plays an important role in fish reproduction. As a first step to understand the physiological role of the GH-IGF system in the ovarian development of starry flounder (Platichthys stellatus), the expression profiles of GH and IGF messenger RNAs (mRNAs) and plasma GH, IGF-I, estradiol-17β (E2), and testosterone (T) levels during the ovarian development were investigated. The developmental stages of ovaries were divided into five stages (II, III, IV, V, and VI) by histological analysis. The hepatosomatic index (HSI) and gonadosomatic index (GSI) values increased and peaked at stage IV and stage V, respectively, and then declined at stage VI. Pituitary GH mRNA levels decreased sharply at stage III and raised to top level at stage VI. The hepatic IGF-I mRNA levels ascended to maximum value at stage V and then declined significantly at stage VI. However, the hepatic IGF-II mRNA levels remained stable and increased significantly at stage VI. In contrast, the ovarian IGF-I mRNA levels increased gradually and peaked at stage VI. The ovarian IGF-II mRNA levels were initially stable and increased significantly at stage V until the top level at stage VI. Consistent with the pituitary GH mRNA levels, plasma GH levels reduced sharply at stage III and remained depressed until stage V and then raised remarkably at stage VI. Plasma IGF-I level peaked at stage V and then declined to initial level. Plasma E2 level peaked at stage IV and then dramatically descended to the basal level. Plasma T level peaked at stage V and then declined significantly back to the basal level. Based on statistical analysis, significant positive correlations between hepatic IGF-I mRNA and GSI, ovarian IGF-II mRNA and hepatic IGF-II mRNA, ovarian IGF-I mRNA and ovarian IGF-II mRNA, and plasma IGF-I and plasma T were observed, respectively. These results suggest that the GH-IGF system may be involved in the ovarian development of starry flounder; GH and IGFs appear to play distinct roles in the regulation of the ovarian development in paracrine/autocrine manners. These findings extend our knowledge of the roles of the GH-IGF axis on reproduction regulation in fish.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frolov, A. A., E-mail: frolov@ihed.ras.ru
2016-12-15
A theory of generation of terahertz radiation under laser–cluster interaction, developed earlier for an overdense cluster plasma [A. A. Frolov, Plasma Phys. Rep. 42. 637 (2016)], is generalized for the case of arbitrary electron density. The spectral composition of radiation is shown to substantially depend on the density of free electrons in the cluster. For an underdense cluster plasma, there is a sharp peak in the terahertz spectrum at the frequency of the quadrupole mode of a plasma sphere. As the electron density increases to supercritical values, this spectral line vanishes and a broad maximum at the frequency comparable withmore » the reciprocal of the laser pulse duration appears in the spectrum. The dependence of the total energy of terahertz radiation on the density of free electrons is analyzed. The radiation yield is shown to increase significantly under resonance conditions, when the laser frequency is close to the eigenfrequency of the dipole or quadrupole mode of a plasma sphere.« less
Contribution of ASDEX Upgrade to disruption studies for ITER
NASA Astrophysics Data System (ADS)
Pautasso, G.; Zhang, Y.; Reiter, B.; Giannone, L.; Gruber, O.; Herrmann, A.; Kardaun, O.; Khayrutdinov, K. K.; Lukash, V. E.; Maraschek, M.; Mlynek, A.; Nakamura, Y.; Schneider, W.; Sias, G.; Sugihara, M.; ASDEX Upgrade Team
2011-10-01
This paper describes the most recent contributions of ASDEX Upgrade to ITER in the field of disruption studies. (1) The ITER specifications for the halo current magnitude are based on data collected from several tokamaks and summarized in the plot of the toroidal peaking factor versus the maximum halo current fraction. Even if the maximum halo current in ASDEX Upgrade reaches 50% of the plasma current, the duration of this maximum lasts a fraction of a ms. (2) Long-lasting asymmetries of the halo current are rare and do not give rise to a large asymmetric component of the mechanical forces on the machine. Differently from JET, these asymmetries are neither locked nor exhibit a stationary harmonic structure. (3) Recent work on disruption prediction has concentrated on the search for a simple function of the most relevant plasma parameters, which is able to discriminate between the safe and pre-disruption phases of a discharge. For this purpose, the disruptions of the last four years have been classified into groups and then discriminant analysis is used to select the most significant variables and to derive the discriminant function. (4) The attainment of the critical density for the collisional suppression of the runaway electrons seems to be technically and physically possible on our medium size tokamak. The CO2 interferometer and the AXUV diagnostic provide information on the highly 3D impurity transport process during the whole plasma quench.
Formation of high-β plasma and stable confinement of toroidal electron plasma in Ring Trap 1a)
NASA Astrophysics Data System (ADS)
Saitoh, H.; Yoshida, Z.; Morikawa, J.; Furukawa, M.; Yano, Y.; Kawai, Y.; Kobayashi, M.; Vogel, G.; Mikami, H.
2011-05-01
Formation of high-β electron cyclotron resonance heating plasma and stable confinement of pure electron plasma have been realized in the Ring Trap 1 device, a magnetospheric configuration generated by a levitated dipole field magnet. The effects of coil levitation resulted in drastic improvements of the confinement properties, and the maximum local β value has exceeded 70%. Hot electrons are major component of electron populations, and its particle confinement time is 0.5 s. Plasma has a peaked density profile in strong field region [H. Saitoh et al., 23rd IAEA Fusion Energy Conference EXC/9-4Rb (2010)]. In pure electron plasma experiment, inward particle diffusion is realized, and electrons are stably trapped for more than 300 s. When the plasma is in turbulent state during beam injection, plasma flow has a shear, which activates the diocotron (Kelvin-Helmholtz) instability. The canonical angular momentum of the particle is not conserved in this phase, realizing the radial diffusion of charged particles across closed magnetic surfaces. [Z. Yoshida et al., Phys Rev. Lett. 104, 235004 (2010); H. Saitoh et al., Phys. Plasmas 17, 112111 (2010).].
Two-plasmon decay instability in inhomogeneous plasmas at oblique laser incidence
Wen, H.; Maximov, A. V.; Short, R. W.; ...
2016-09-30
The two-plasmon decay (TPD) and stimulated Raman scattering (SRS) instabilities have been studied in the region near the quarter-critical density in the plasmas of the laser-driven inertial confinement fusion for a wide range of laser angles of incidence. The theoretical analysis of the TPD for oblique laser incidence has been carried out. The theoretical growth rates and thresholds have been compared with the results of the fluid-type simulations, and a good agreement has been found. Here, in the modeling including both TPD and SRS, the spectra of the growing perturbations have multiple peaks, and the maximum growth may be influencedmore » by the interplay between TPD and SRS.« less
Hwang, Ju Hyun; Lee, Hyun Jun; Shim, Yong Sub; Park, Cheol Hwee; Jung, Sun-Gyu; Kim, Kyu Nyun; Park, Young Wook; Ju, Byeong-Kwon
2015-02-14
Extremely low-haze light extraction from organic light-emitting diodes (OLEDs) was achieved by utilizing nanoscale corrugation, which was simply fabricated with plasma treatment and sonication. The haze of the nanoscale corrugation for light extraction (NCLE) corresponds to 0.21% for visible wavelengths, which is comparable to that of bare glass. The OLEDs with NCLE showed enhancements of 34.19% in current efficiency and 35.75% in power efficiency. Furthermore, the OLEDs with NCLE exhibited angle-stable electroluminescence (EL) spectra for different viewing angles, with no change in the full width at half maximum (FWHM) and peak wavelength. The flexibility of the polymer used for the NCLE and plasma treatment process indicates that the NCLE can be applied to large and flexible OLED displays.
Chen, Cuiping; Cowles, Verne E; Hou, Eddie
2011-03-01
The objectives of the 3 phase I studies described herein were (1) to compare the pharmacokinetics of gabapentin delivered from a novel gastric-retentive dosage form vs an immediate-release formulation, (2) to assess the dose proportionality of the gastric-retentive extended-release formulation, and (3) to determine the effect of food on the pharmacokinetics of gabapentin delivered from this formulation. The time to reach maximum plasma concentration (t(max)) was extended for gabapentin delivered from the gastric-retentive extended-release formulation compared with the immediate-release formulation. A dose-related increase in both the maximum plasma concentration (C(max)) and the area under the plasma concentration-time curve (AUC) was observed as the gabapentin dose increased from 600 to 2400 mg. Fed status and increased fat content delayed t(max) and enhanced C(max) and AUC in proportion to the fat content. The pharmacokinetics of gabapentin delivered from this extended-release formulation allows a reduced dosing frequency while maintaining bioavailability and possibly diminishing the occurrence of adverse events attributable to a slower increase to the peak concentration compared with the immediate-release dosage form.
Explosive plasma flows in a solar flare
NASA Technical Reports Server (NTRS)
Zarro, Dominic M.; Canfield, Richard C.; Metcalf, Thomas R.; Strong, Keith T.
1988-01-01
Solar Maximum Mission soft X-ray data and Sacramento Peak Observatory H-alpha observations are combined in a study of the impulsive phase of a solar flare. A blue asymmetry, indicative of upflows, was observed in the coronal Ca XIX line during the soft X-ray rise phase. A red asymmetry, indicative of downflows, was observed simultaneously in chromospheric H-alpha emitted from bright flare kernels during the period of hard X-ray emission. Combining the velocity data with a measurement of coronal electron density, it is shown that the impulsive phase momentum of upflowing soft X-ray-emitting plasma equalled that of the downflowing H-alpha-emitting plasma to within one order of magnitude. In particular, the momentum of the upflowing plasma was 2 x 10 to the 21st g cm/s while that of the downflowing plasma was 7 x 10 to the 21st g cm/s, with a factor of 2 uncertainty on each value. This equality supports the explosive chromospheric evaporation model of solar flares, in which a sudden pressure increase at the footprint of a coronal loop produces oppositely directed flows in the heated plasma.
NASA Astrophysics Data System (ADS)
Agudo, Iván; Jorstad, Svetlana G.; Marscher, Alan P.; Larionov, Valeri M.; Gómez, José L.; Lähteenmäki, Anne; Gurwell, Mark; Smith, Paul S.; Wiesemeyer, Helmut; Thum, Clemens; Heidt, Jochen; Blinov, Dmitriy A.; D'Arcangelo, Francesca D.; Hagen-Thorn, Vladimir A.; Morozova, Daria A.; Nieppola, Elina; Roca-Sogorb, Mar; Schmidt, Gary D.; Taylor, Brian; Tornikoski, Merja; Troitsky, Ivan S.
2011-01-01
We combine time-dependent multi-waveband flux and linear polarization observations with submilliarcsecond-scale polarimetric images at λ = 7 mm of the BL Lacertae type blazar OJ287 to locate the γ-ray emission in prominent flares in the jet of the source >14 pc from the central engine. We demonstrate a highly significant correlation between the strongest γ-ray and millimeter-wave flares through Monte Carlo simulations. The two reported γ-ray peaks occurred near the beginning of two major millimeter-wave outbursts, each of which is associated with a linear polarization maximum at millimeter wavelengths. Our very long baseline array observations indicate that the two millimeter-wave flares originated in the second of two features in the jet that are separated by >14 pc. The simultaneity of the peak of the higher-amplitude γ-ray flare and the maximum in polarization of the second jet feature implies that the γ-ray and millimeter-wave flares are cospatial and occur >14 pc from the central engine. We also associate two optical flares, accompanied by sharp polarization peaks, with the two γ-ray events. The multi-waveband behavior is most easily explained if the γ-rays arise from synchrotron self-Compton scattering of optical photons from the flares. We propose that flares are triggered by interaction of moving plasma blobs with a standing shock. The γ-ray and optical emission is quenched by inverse Compton losses as synchrotron photons from the newly shocked plasma cross the emission region. The millimeter-wave polarization is high at the onset of a flare, but decreases as the electrons emitting at these wavelengths penetrate less polarized regions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Agudo, Ivan; Jorstad, Svetlana G.; Marscher, Alan P.
We combine time-dependent multi-waveband flux and linear polarization observations with submilliarcsecond-scale polarimetric images at {lambda} = 7 mm of the BL Lacertae type blazar OJ287 to locate the {gamma}-ray emission in prominent flares in the jet of the source >14 pc from the central engine. We demonstrate a highly significant correlation between the strongest {gamma}-ray and millimeter-wave flares through Monte Carlo simulations. The two reported {gamma}-ray peaks occurred near the beginning of two major millimeter-wave outbursts, each of which is associated with a linear polarization maximum at millimeter wavelengths. Our very long baseline array observations indicate that the two millimeter-wavemore » flares originated in the second of two features in the jet that are separated by >14 pc. The simultaneity of the peak of the higher-amplitude {gamma}-ray flare and the maximum in polarization of the second jet feature implies that the {gamma}-ray and millimeter-wave flares are cospatial and occur >14 pc from the central engine. We also associate two optical flares, accompanied by sharp polarization peaks, with the two {gamma}-ray events. The multi-waveband behavior is most easily explained if the {gamma}-rays arise from synchrotron self-Compton scattering of optical photons from the flares. We propose that flares are triggered by interaction of moving plasma blobs with a standing shock. The {gamma}-ray and optical emission is quenched by inverse Compton losses as synchrotron photons from the newly shocked plasma cross the emission region. The millimeter-wave polarization is high at the onset of a flare, but decreases as the electrons emitting at these wavelengths penetrate less polarized regions.« less
NASA Astrophysics Data System (ADS)
Zhang, Yu-Ru; Hu, Yan-Ting; Gao, Fei; Song, Yuan-Hong; Wang, You-Nian
2018-05-01
A novel method, the so-called electrical asymmetry effect (EAE), is gaining increasing interest for realizing the separate control of the ion flux and ion energy. In this paper, a two-dimensional fluid model combined with the full set of Maxwell equations is used to investigate the plasma properties in an electrically asymmetric capacitive discharge sustained by multiple consecutive harmonics operating in the very high frequency regime. The results indicate that by increasing the total number of consecutive harmonics k, the modulation of the dc self-bias induced by changing {θ }1 (the relative phase of the fundamental frequency) becomes different, especially for k ≤slant 6. In a discharge driven by eight consecutive harmonics, the dc self-bias varies with a period 2π, and the most positive value appears at {θ }1 = 3π/2. In addition, with the electromagnetic effects taken into account, the plasma density shifts from edge-high to uniform when {θ }1 increases from 0 to π, and the maximum moves again towards the radial wall at {θ }1 = 3π/2. Moreover, the transient behavior of electrodynamics is also important for a better understanding of the EAE. Within a period, three positive peaks of {P}z are observed, which cause substantial ionization at similar places. {P}r is characterized by a pronounced peak at the end of the period, and the lowest peak value appears at {θ }1 = π. The results obtained in this work are important for improving the plasma processes by utilizing the EAE, especially when the higher order harmonics are included.
Physical fitness and plasma leptin in women with recent gestational diabetes.
Gar, C; Rottenkolber, M; Grallert, H; Banning, F; Freibothe, I; Sacco, V; Wichmann, C; Reif, S; Potzel, A; Dauber, V; Schendell, C; Sommer, N N; Wolfarth, B; Seissler, J; Lechner, A; Ferrari, U
2017-01-01
Low physical fitness (PF) is a risk factor for type 2 diabetes mellitus (T2D). Women with a history of gestational diabetes (GDM) are at risk for T2D at a young age, but the role of PF in this population is not clear. PF has also been found to correlate inversely with plasma leptin in previous studies. Here, we examine whether women who had GDM have lower PF than women after a normoglycemic pregnancy and, second, whether PF is associated with plasma leptin, independently of body fat mass. Cross-sectional analysis of 236 participants in the PPSDiab Study (cohort study of women 3-16 months after delivery, 152 after gestational diabetes (pGDM), 84 after normoglycemic pregnancy (control subjects); consecutively recruited 2011-16); medical history, physical examination with bioelectrical impedance analysis (BIA), whole body magnetic resonance imaging (MRI) (n = 154), 5-point oral glucose tolerance test, cardiopulmonary exercise testing, clinical chemistry including fasting plasma leptin; statistical analysis with Mann-Whitney U and t -test, Spearman correlation coefficient, multiple linear regression. Women pGDM had lower maximally achieved oxygen uptake (VO2peak/kg: 25.7(21.3-29.9) vs. 30.0(26.6-34.1)ml/min/kg; total VO2peak: 1733(1552-2005) vs. 1970(1767-2238)ml/min; p<0.0001 for both), and maximum workload (122.5(105.5-136.5) vs. 141.0(128.5-159.5)W; p<0.0001). Fasting plasma leptin correlated inversely with PF (VO2peak/kg ρ = -0.72 p<0.0001; VO2peak ρ = -0.16 p = 0.015; max. load ρ = -0.35 p<0.0001). These associations remained significant with adjustment for body mass index, or for body fat mass (BIA and MRI). Women with a recent history of GDM were less fit than control subjects. Low PF may therefore contribute to the risk for T2D after GDM. This should be tested in intervention studies. Low PF also associated with increased leptin levels-independently of body fat. PF may therefore influence leptin levels and signaling. This hypothesis requires further investigation.
Plasma-Filled Rod-Pinch Diode Research on Gamble II
2007-06-01
by the dashed red line in Fig. 3. CaF2 thermoluminescent dosimeters ( TLDs ) located on the front surface of the rolled edge measure the dose. The...half-maximum line-spread function] and high dose [23 rad(CaF2) at 1 m] with 1-2 MeV electron energies are unique capabilities that the PFRP offers...for radiographic imaging in this electron -energy range. The source distribution has a narrow central peak that can enhance the spatial resolution
Plasmonic properties of gold nanoparticles covered by silicon suboxide thin film
NASA Astrophysics Data System (ADS)
Baranov, Evgeniy; Zamchiy, Alexandr; Safonov, Aleksey; Starinskiy, Sergey; Khmel, Sergey
2017-10-01
The optical properties of nanocomposite material consisting of gold nanoparticles without/with silicon suboxide thin film were obtained. The gold film was deposited by thermal vacuum evaporation and then it was annealed in a vacuum chamber to form gold nanoparticles. The silicon suboxide thin films were deposited by the gas-jet electron beam plasma chemical vapor deposition method. The intensity of the localized surface plasmon resonance increased and the plasmon maximum peak shifted from 520 nm to 537 nm.
431 kA/cm2 peak tunneling current density in GaN/AlN resonant tunneling diodes
NASA Astrophysics Data System (ADS)
Growden, Tyler A.; Zhang, Weidong; Brown, Elliott R.; Storm, David F.; Hansen, Katurah; Fakhimi, Parastou; Meyer, David J.; Berger, Paul R.
2018-01-01
We report on the design and fabrication of high current density GaN/AlN double barrier resonant tunneling diodes grown via plasma assisted molecular-beam epitaxy on bulk GaN substrates. A quantum-transport solver was used to model and optimize designs with high levels of doping and ultra-thin AlN barriers. The devices displayed repeatable room temperature negative differential resistance with peak-to-valley current ratios ranging from 1.20 to 1.60. A maximum peak tunneling current density (Jp) of 431 kA/cm2 was observed. Cross-gap near-UV (370-385 nm) electroluminescence (EL) was observed above +6 V when holes, generated from a polarization induced Zener tunneling effect, recombine with electrons in the emitter region. Analysis of temperature dependent measurements, thermal resistance, and the measured EL spectra revealed the presence of severe self-heating effects.
NASA Astrophysics Data System (ADS)
Nakao, S.; Sonoda, T.
2013-03-01
Diamond-like carbon (DLC) films are prepared by a bipolar-type plasma based ion implantation, and the structural differences between DLC films deposited on different electrical conductive substrates, i.e., conductive Si wafers and insulating glass plates are examined by Raman spectroscopy and x-ray photo emission spectroscopy (XPS). In the Raman measurements, graphite (G) and disorder (D) peaks are observed for both samples. However, the additional photo luminescence is overlapped on the spectra in the case of on-glass sample. To elucidate the structural difference, the intensity ratio of D to G peak (I(D)/I(G)), G peak position and full width at half maximum (FWHM) are obtained by curve fitting using Gaussian function and linear baseline. It is found that the I(D)/I(G) is lower, G peak position is higher and FWHM of G peak is narrower for on-glass sample than for on-Si sample. According to Robertson [1], lower I(D)/I(G) seems more sp3 C-C bonding in amount for on-glass sample. In contrast, higher G peak position and narrower FWHM of G peak suggest less sp3 C-C bonding in amount for on-glass sample. The results of XPS analysis with C1s spectra reveal that sp3 ratio, i.e., the intensity ratio of sp3/(sp3+sp2) is smaller for on-glass sample than for on-Si sample. The inconsistency of the trend between I(D)/I(G) and other parameters (G peak position and FWHM of G peak) might be caused by the overlap of photo luminescence signal on Raman spectrum as to on-glass sample. From these results, it is considered that sp3 C-C bonding is reduced in amount when using insulating substrate in comparison with conductive substrate.
High charge state carbon and oxygen ions in Earth's equatorial quasi-trapping region
NASA Technical Reports Server (NTRS)
Christon, S. P.; Hamilton, D. C.; Gloeckler, G.; Eastmann, T. E.
1994-01-01
Observations of energetic (1.5 - 300 keV/e) medium-to-high charge state (+3 less than or equal to Q less than or equal to +7) solar wind origin C and O ions made in the quasi-trapping region (QTR) of Earth's magnetosphere are compared to ion trajectories calculated in model equatorial magnetospheric magnetic and electric fields. These comparisons indicate that solar wind ions entering the QTR on the nightside as an energetic component of the plasma sheet exit the region on the dayside, experiencing little or no charge exchange on the way. Measurements made by the CHarge Energy Mass (CHEM) ion spectrometer on board the Active Magnetospheric Particle Tracer Explorer/Charge Composition Explorer (AMPTE/CCE) spacecraft at 7 less than L less than 9 from September 1984 to January 1989 are the source of the new results contained herein: quantitative long-term determination of number densities, average energies, energy spectra, local time distributions, and their variation with geomagnetic disturbance level as indexed by Kp. Solar wind primaries (ions with charge states unchanged) and their secondaries (ions with generally lower charge states produced from primaries in the magnetosphere via charge exchange)are observed throughout the QTR and have distinctly different local time variations that persist over the entire 4-year analysis interval. During Kp larger than or equal to 3 deg intervals, primary ion (e.g., O(+6)) densities exhibit a pronounced predawn maximum with average energy minimum and a broad near-local-noon density minimum with average energy maximum. Secondary ion (e.g., O(+5)) densities do not have an identifiable predawn peak, rather they have a broad dayside maximum peaked in local morning and a nightside minimum. During Kp less than or equal to 2(-) intervals, primary ion density peaks are less intense, broader in local time extent, and centered near midnight, while secondary ion density local time variations diminish. The long-time-interval baseline helps to refine and extend previous observations; for example, we show that ionospheric contribution to O(+3)) is negligible. Through comparison with model ion trajectories, we interpret the lack of pronounced secondary ion density peaks colocated with the primary density peaks to indicate that: (1) negligible charge exchange occurs at L greater than 7, that is, solar wind secondaries are produced at L less than 7, and (2) solar wind secondaries do not form a significant portion of the plasma sheet population injected into the QTR. We conclude that little of the energetic solar wind secondary ion population is recirculated through the magnetosphere.
NASA Astrophysics Data System (ADS)
Chen, Zhaoquan; Yin, Zhixiang; Chen, Minggong; Hong, Lingli; Xia, Guangqing; Hu, Yelin; Huang, Yourui; Liu, Minghai; Kudryavtsev, A. A.
2014-10-01
In present study, a pulsed lower-power microwave-driven atmospheric-pressure argon plasma jet has been introduced with the type of coaxial transmission line resonator. The plasma jet plume is with room air temperature, even can be directly touched by human body without any hot harm. In order to study ionization process of the proposed plasma jet, a self-consistent hybrid fluid model is constructed in which Maxwell's equations are solved numerically by finite-difference time-domain method and a fluid model is used to study the characteristics of argon plasma evolution. With a Guass type input power function, the spatio-temporal distributions of the electron density, the electron temperature, the electric field, and the absorbed power density have been simulated, respectively. The simulation results suggest that the peak values of the electron temperature and the electric field are synchronous with the input pulsed microwave power but the maximum quantities of the electron density and the absorbed power density are lagged to the microwave power excitation. In addition, the pulsed plasma jet excited by the local enhanced electric field of surface plasmon polaritons should be the discharge mechanism of the proposed plasma jet.
Investigation of molten pool oscillation during GMAW-P process based on a 3D model
NASA Astrophysics Data System (ADS)
Wang, L. L.; Lu, F. G.; Cui, H. C.; Tang, X. H.
2014-11-01
In order to better reveal the oscillation mechanism of the pulsed gas metal arc welding (GMAW-P) process due to an alternately varied welding current, arc plasma and molten pool oscillation were simulated through a self-consistent three-dimensional model. Based on an experimental analysis of the dynamic variation of the arc plasma and molten pool captured by a high-speed camera, the model was validated by comparison of the measured and predicted results. The calculated results showed that arc pressure was the key factor causing the molten pool to oscillate. The variation in arc size and temperature from peak time to base time resulted in a great difference in the heat input and arc pressure acting on the molten pool. The surface deformation of the molten pool due to the varying degrees of arc pressure induced alternate displacement and backflow in the molten metal. The periodic iteration of deeper and shallower surface deformation, drain and backflow of molten metal caused the molten pool to oscillate at a certain frequency. In this condition, the arc pressure at the peak time is more than six times higher than that at the base time, and the maximum surface depression is 1.4 mm and 0.6 mm, respectively, for peak time and base time.
Grotzkyj Giorgi, Margherita; Howland, Kevin; Martin, Colin; Bonner, Adrian B.
2012-01-01
An HPLC method was developed and validated for the concurrent detection and quantitation of seven water-soluble vitamins (C, B1, B2, B5, B6, B9, B12) in biological matrices (plasma and urine). Separation was achieved at 30°C on a reversed-phase C18-A column using combined isocratic and linear gradient elution with a mobile phase consisting of 0.01% TFA aqueous and 100% methanol. Total run time was 35 minutes. Detection was performed with diode array set at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples (24 plasma and urine samples from abstinent alcohol-dependent males). Interday and intraday precision were <4% and <7%, respectively, for all vitamins. Recovery percentages ranged from 93% to 100%. PMID:22536136
Giorgi, Margherita Grotzkyj; Howland, Kevin; Martin, Colin; Bonner, Adrian B
2012-01-01
An HPLC method was developed and validated for the concurrent detection and quantitation of seven water-soluble vitamins (C, B(1), B(2), B(5), B(6), B(9), B(12)) in biological matrices (plasma and urine). Separation was achieved at 30°C on a reversed-phase C18-A column using combined isocratic and linear gradient elution with a mobile phase consisting of 0.01% TFA aqueous and 100% methanol. Total run time was 35 minutes. Detection was performed with diode array set at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples (24 plasma and urine samples from abstinent alcohol-dependent males). Interday and intraday precision were <4% and <7%, respectively, for all vitamins. Recovery percentages ranged from 93% to 100%.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, Mahesh; Central Research Laboratory, Bharat Electronics, Bangalore 560 013; Bhat, Thirumaleshwara N.
Highlights: ► The n-type GaN layers were grown by plasma-assisted molecular beam epitaxy. ► The optical characteristics of a donor level in Si-doped GaN were studied. ► Activation energy of a Si-related donor was estimated from temperature dependent PL measurements. ► PL peak positions, FWHM of PL and activation energies are found to be proportional to the cube root of carrier density. ► The involvement of donor levels is supported by the temperature-dependent electron concentration measurements. -- Abstract: The n-type GaN layers were grown by plasma-assisted MBE and either intentionally doped with Si or unintentionally doped. The optical characteristics ofmore » a donor level in Si-doped, GaN were studied in terms of photoluminescence (PL) spectroscopy as a function of electron concentration. Temperature dependent PL measurements allowed us to estimate the activation energy of a Si-related donor from temperature-induced decay of PL intensity. PL peak positions, full width at half maximum of PL and activation energies are found to be proportional to the cube root of carrier density. The involvement of donor levels is supported by the temperature-dependent electron concentration measurements.« less
NASA Astrophysics Data System (ADS)
Linbo, GU; Yixi, CAI; Yunxi, SHI; Jing, WANG; Xiaoyu, PU; Jing, TIAN; Runlin, FAN
2017-11-01
To explore the effect of the gas source flow rate on the actual diesel exhaust particulate matter (PM), a test bench for diesel engine exhaust purification was constructed, using indirect non-thermal plasma technology. The effects of different gas source flow rates on the quantity concentration, composition, and apparent activation energy of PM were investigated, using an engine exhaust particle sizer and a thermo-gravimetric analyzer. The results show that when the gas source flow rate was large, not only the maximum peak quantity concentrations of particles had a large drop, but also the peak quantity concentrations shifted to smaller particle sizes from 100 nm to 80 nm. When the gas source flow rate was 10 L min-1, the total quantity concentration greatly decreased where the removal rate of particles was 79.2%, and the variation of the different mode particle proportion was obvious. Non-thermal plasma (NTP) improved the oxidation ability of volatile matter as well as that of solid carbon. However, the NTP gas source rate had little effects on oxidation activity of volatile matter, while it strongly influenced the oxidation activity of solid carbon. Considering the quantity concentration and oxidation activity of particles, a gas source flow rate of 10 L min-1 was more appropriate for the purification of particles.
Atomic oxygen ions as ionospheric biomarkers on exoplanets
NASA Astrophysics Data System (ADS)
Mendillo, Michael; Withers, Paul; Dalba, Paul A.
2018-04-01
The ionized form of atomic oxygen (O+) is the dominant ion species at the altitude of maximum electron density in only one of the many ionospheres in our Solar System — Earth's. This ionospheric composition would not be present if oxygenic photosynthesis was not an ongoing mechanism that continuously impacts the terrestrial atmosphere. We propose that dominance of ionospheric composition by O+ ions at the altitude of maximum electron density can be used to identify a planet in orbit around a solar-type star where global-scale biological activity is present. There is no absolute numerical value required for this suggestion of an atmospheric plasma biomarker — only the dominating presence of O+ ions at the altitude of peak electron density.
Sealey, J E; Atlas, S A; Glorioso, N; Manapat, H; Laragh, J H
1985-01-01
Plasma prorenin, a high molecular weight precursor form of renin, (renin, EC 3.4.23.15; old number, EC 3.4.99.19), was measured three times weekly in normal young women during the menstrual cycle and was related to changes in luteinizing hormone, estradiol, and progesterone. In all subjects a stable baseline level of prorenin occurred during the follicular phase. Then, simultaneously or soon after the luteinizing hormone peak, plasma prorenin consistently increased about 2-fold. Baseline prorenin ranged from 18 to 40 ng per ml per hr, and peak prorenin ranged from 35 to 65 ng per ml per hr. The maximum increase in prorenin averaged 80%. Prorenin remained elevated during the mid-luteal phase of the menstrual cycle and returned to baseline during the late-luteal phase in coordination with the decrease in progesterone. The changes in prorenin were not synchronized with changes in active renin which was significantly increased only during the mid-luteal phase. These findings suggest that prorenin may be involved in reproductive physiology. PMID:3909151
An observational study of the nightside ionospheres of Mars and Venus with radio occultation methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, M.H.G.; Luhmann, J.G.; Kliore, A.J.
1990-10-01
An analysis of Mars and Venus nightside electron density profiles obtained with radio occultation methods shows how the nightside ionospheres of both planets vary with solar zenith angle. From previous studies it is known that the dayside peak electron densities at Mars and Venus show a basic similarity in that they both exhibit Chapman layer-like behavior. In contrast, the peak altitudes at mars behave like an ideal Chapman layer on the dayside, whereas the altitude of the peak at Venus is fairly constant up to the terminator. The effect of major dust storms can also be seen in the peakmore » altitudes at Mars. All Venus nightside electron density profiles show a distinct main peak for both solar minimum and maximum, whereas many profiles from the nightside of Mars do not show any peak at all. This suggests that the electron density in the Mars nightside ionosphere is frequently too low to be detected by radio occultation. On the Pioneer Venus orbiter, disappearing ionospheres were observed near solar maximum in the in-situ data when the solar wind dynamic pressure was exceptionally high. This condition occurs because the high solar wind dynamic pressure decreases the altitude of the ionopause near the terminator below {approximately}250 km, thus reducing the normal nightward transport of dayside ionospheric plasma. On the basis of the Venus observations, one might predict that if a positive correlation of nightside peak density with dynamic pressure was found, it could mean that transport from the dayside is the only significant source for the nightside ionosphere of Mars. The lack of a correlation would imply that the precipitation source at Mars is quite variable.« less
NASA Technical Reports Server (NTRS)
Sakata, Akira; Wada, Setsuko; Tokunaga, Alan T.; Narisawa, Takatoshi; Nakagawa, Hidehiro; Ono, Hiroshi
1994-01-01
QCCs (quenched carbonaceous composite) are amorphus carbonaceous material formed from a hydrocarbon plasma. We present the UV-visible spectra of 'filmy QCC; (obtained outside of the beam ejected from the hydrocarbon plasma) and 'dark QCC' (obtained very near to the beam) for comparison to the stellar extinction curve. When filmy QCC is heated to 500-700 C (thermally altered), the wavelength of the absorption maximum increases form 204 nm to 220-222 nm. The dark QCC has an absorption maximum at 217-222 nm. In addition, the thermally altered filmy QCC has a slope change at about 500 nm which resmbles that in the interstellar extinction curve. The resemblance of the extinction curve of the QCCs to that of the interstellar medium suggests that QCC derivatives may be representative of the type of interstellar material that produces the 217 nm interstellar medium feature. The peak extinction of the dark QCC is higher than the average interstellar extinction curve while that of the thermally altered filmy QCC is lower, so that a mixture of dark and thermally altered filmy QCC can match the peak extinction observed in the interstellar medium. It is shown from electron micrographs that most of the thermally altered flimy QCC is in the form of small grainy structure less than 4 nm in diameter. This shows that the structure unit causing the 217-222 nm feature in QCC is very small.
Effect of frequency on the uniformity of symmetrical RF CCP discharges
NASA Astrophysics Data System (ADS)
Liu, Yue; Booth, Jean-Paul; Chabert, Pascal
2018-05-01
A 2D Cartesian electrostatic particle-in-cell/Monte Carlo collision (PIC/MCC) model presented previously (Liu et al 2018 Plasma Sources Sci. Technol. 27 025006) is used to investigate the effect of the driving frequency (over the range of 15–45 MHz) on the plasma uniformity in radio frequency (RF) capacitively coupled plasma (CCP) discharges in a geometrically symmetric reactor with a dielectric side wall in argon gas. The reactor size (12 cm electrode length, 2.5 cm gap) and driving frequency are sufficiently small that electromagnetic effects can be ignored. Previously, we showed (Liu et al 2018 Plasma Sources Sci. Technol. 27 025006) that for 15 MHz excitation, Ohmic heating of electrons by the electric field perpendicular to the electrodes is enhanced in a region in front of the dielectric side wall, leading to a maximum in electron density there. In this work we show that increasing the excitation frequency (at constant applied voltage amplitude) not only increases the overall electron heating and density but also causes a stronger, narrower peak in electron heating closer to the dielectric wall, improving the plasma uniformity along the electrodes. This heating peak comes both from enhanced perpendicular electron heating and from the appearance at high frequency of significant parallel heating. The latter is caused by the presence of a significant parallel-direction RF oscillating electric field in the corners. Whereas at the reactor center the sheaths oscillate perpendicularly to the electrodes, near the dielectric edge they move in and out of the corners and must be treated in two dimensions.
Effect of dimethicone (polysilane gel) on the stereoselective pharmacokinetics of ketoprofen.
Presle, N; Lapicque, F; Gillet, P; Herrmann, M A; Bannwarth, B; Netter, P
1998-06-01
Since dimethicone may be employed to improve gastrointestinal tolerability of non steroidal anti-inflammatory drugs (NSAIDs), we studied its influence on the pharmacokinetics of ketoprofen in subjects receiving a single oral dose of racemic ketoprofen. In a cross-over experimental design, 12 healthy fasting volunteers were given a single oral dose (100 mg) of racemic ketoprofen, administered with or without dimethicone. The kinetic parameters measured were area under the concentration (AUC), maximum peak plasma concentration (Cmax), time to reach peak concentration (tmax), elimination half-life (t1/2), mean residence time (MRT) and urinary excretion for R and S enantiomers. Dimethicone reduced the peak concentration of both R and S ketoprofen by about 10% (P<0.05) and also induced a slight but non-significant increase in the mean time to achieve peak concentration. However, this treatment had no significant effect on the bioavailability and the elimination of R and S enantiomers, as shown by AUC, t1/2 and MRT values. The absorption patterns were equivalent for both ketoprofen isomers, since plasma pharmacokinetic parameters were similar. Nevertheless, the urinary recovery was significantly lower for R ketoprofen than for its antipode. The administration of dimethicone did not alter this stereoselectivity. The administration of dimethicone to alleviate the epigastralgic effects related to NSAIDs does not affect the efficacy of the treatment. Dimethicone did not significantly alter the bioavailability of ketoprofen, chosen as an example of an NSAID, especially that of the pharmacologically active S enantiomer.
Assessment of extended-release opioid analgesics for the treatment of chronic pain.
Gudin, Jeffrey A
2013-03-01
Approximately 3.8 million patients annually receive extended-release (ER) or long-acting opioid prescriptions in the outpatient setting, around half of which are written by primary care physicians. Compared with short-acting, immediate-release (IR) formulations, ER and oral long-acting opioid analgesics are associated with clinical advantages, such as extended periods of time during which drug plasma levels are within the therapeutic range, decreased peak-to-trough fluctuations, and prolonged analgesia over the dosing period. Additionally, ER opioids offer a more convenient, less frequent dosing regimen to chronic pain patients who are often taking several concomitant medications. The increased utilization of ER opioids has been accompanied by a rise in the misuse and abuse of these formulations. Certain pharmacokinetic parameters (e.g., longer time to maximum drug plasma concentration, lower maximum drug plasma concentration) may decrease the abuse potential of intact ER opioids by limiting the positive subjective and reinforcing effects relative to IR formulations. Putative abuse-deterrent formulations have also recently been introduced to impede physical manipulation of these formulations, or reduce the harm resulting from such behavior. Such formulations may represent an incremental advance to reduce non-oral forms of abuse. This article reviews the pharmacokinetic profiles and abuse-deterrent features of newer ER opioid analgesics for the treatment of moderate to severe chronic pain.
Jang, Y D; Ma, J Y; Monegue, J S; Monegue, H J; Stuart, R L; Lindemann, M D
2015-11-01
Piglets are born with purportedly low plasma vitamin D levels. The objective of this study was to investigate the effect of fat-soluble vitamin administration, primarily vitamin D, by different administration routes on plasma vitamin concentrations in suckling pigs. A total of 45 pigs from 5 litters were allotted at birth to 3 treatments within each litter. Pigs were administered 400 IU of α-tocopherol, 40,000 IU of retinyl palmitate, and 40,000 IU of vitamin D at d 1 of age either orally or by i.m. injection and compared with control pigs with no supplemental vitamin administration. Blood samples were collected at d 0 (initial), 1, 2, 3, 4, 6, 9, 14, and 20 after administration. Plasma 25-hydroxycholecalciferol (25OHD), α-tocopherol, retinyl palmitate, and retinol concentrations were analyzed. Except for retinol, the effects of treatment, day, and day × treatment interaction ( < 0.01) were observed on plasma vitamin concentrations. Plasma concentrations of 25OHD and α-tocopherol increased immediately regardless of administration routes to peak at d 2 and 1 after administration, respectively. Plasma retinyl palmitate concentrations increased only with the injection treatment, with the peak at d 1 after administration. Plasma concentrations of 25OHD in both administration treatments and α-tocopherol in the injection treatment were maintained at greater levels than those in the control treatment until d 20 after administration. With regard to the pharmacokinetic parameters for plasma 25OHD concentrations, the injection treatment had greater elimination half-life ( < 0.01), maximum plasma concentrations ( < 0.05), and all area under the curve parameters ( < 0.01) but a lower elimination rate constant ( < 0.01) than the oral treatment. Relative bioavailability of oral administration compared with injection administration was 55.26%. These results indicate that plasma status of 25OHD,α-tocopherol, and retinyl palmitate are differentially changed between types of vitamins administered and between administration routes and that the injection route had a greater increase and slower disappearance of plasma vitamin levels than the oral route during the suckling period.
Prospect for a 60 GHz multicharged ECR ion source
NASA Astrophysics Data System (ADS)
Thuillier, T.; Bondoux, D.; Angot, J.; Baylac, M.; Froidefond, E.; Jacob, J.; Lamy, T.; Leduc, A.; Sole, P.; Debray, F.; Trophime, C.; Skalyga, V.; Izotov, I.
2018-05-01
The conceptual design of a fourth generation hybrid electron cyclotron resonance (ECR) ion source operated at 60 GHz is proposed. The axial magnetic mirror is generated with a set of three Nb3Sn coils, while the hexapole is made with room temperature (RT) copper coils. The motivations for such a hybrid development are to study further the ECR plasma physics and the intense multicharged ion beams' production and transport at a time when a superconducting (SC) hexapole appears unrealistic at 60 GHz. The RT hexapole coil designed is an evolution of the polyhelix technology developed at the French High Magnetic Field Facility. The axial magnetic field is generated by means of 3 Nb3Sn SC coils operated with a maximum current density of 350 A/mm2 and a maximum coil load line factor of 81%. The ECR plasma chamber resulting from the design features an inner radius of 94 mm and a length of 500 mm. The radial magnetic intensity is 4.1 T at the wall. Characteristic axial mirror peaks are 8 and 4.5 T, with 1.45 T minimum in between.
A spectrophotometric determination of cyanate using reaction with 2-aminobenzoic acid.
Guilloton, M; Karst, F
1985-09-01
A specific method has been devised for the assay of cyanate, based on the reaction with 2-aminobenzoic acid. Cyclization of the product in 6 N HCl results in the formation of 2,4(1H,3H)-quinazolinedione. Cyanate content of the samples can be measured by their absorbances at 310 nm. Alternatively, the second derivatives of the spectra can be recorded; the peak-to-peak height between the first maximum (330 nm) and the first minimum (317 nm) was shown to be proportional to the cyanate content. This method is suitable for the estimation of cyanate in aqueous solutions in the concentration range 0.01 to 2 mM. When added to blood plasma, cyanate could be detected down to 0.1 mM.
30 CFR 817.67 - Use of explosives: Control of adverse effects.
Code of Federal Regulations, 2014 CFR
2014-07-01
... either the maximum peak-particle-velocity limits of paragraph (d)(2), the scaled-distance equation of... authority before the initiation of blasting. (2) Maximum peak-particle velocity. (i) The maximum ground... site, in feet Maximum allowable peak particle velocity (V max) for ground vibration, in inches/second 1...
30 CFR 817.67 - Use of explosives: Control of adverse effects.
Code of Federal Regulations, 2013 CFR
2013-07-01
... either the maximum peak-particle-velocity limits of paragraph (d)(2), the scaled-distance equation of... authority before the initiation of blasting. (2) Maximum peak-particle velocity. (i) The maximum ground... site, in feet Maximum allowable peak particle velocity (V max) for ground vibration, in inches/second 1...
30 CFR 817.67 - Use of explosives: Control of adverse effects.
Code of Federal Regulations, 2012 CFR
2012-07-01
... either the maximum peak-particle-velocity limits of paragraph (d)(2), the scaled-distance equation of... authority before the initiation of blasting. (2) Maximum peak-particle velocity. (i) The maximum ground... site, in feet Maximum allowable peak particle velocity (V max) for ground vibration, in inches/second 1...
30 CFR 817.67 - Use of explosives: Control of adverse effects.
Code of Federal Regulations, 2010 CFR
2010-07-01
... either the maximum peak-particle-velocity limits of paragraph (d)(2), the scaled-distance equation of... authority before the initiation of blasting. (2) Maximum peak-particle velocity. (i) The maximum ground... site, in feet Maximum allowable peak particle velocity (V max) for ground vibration, in inches/second 1...
30 CFR 817.67 - Use of explosives: Control of adverse effects.
Code of Federal Regulations, 2011 CFR
2011-07-01
... either the maximum peak-particle-velocity limits of paragraph (d)(2), the scaled-distance equation of... authority before the initiation of blasting. (2) Maximum peak-particle velocity. (i) The maximum ground... site, in feet Maximum allowable peak particle velocity (V max) for ground vibration, in inches/second 1...
NASA Astrophysics Data System (ADS)
Maulois, Mélissa; Ribière, Maxime; Eichwald, Olivier; Yousfi, Mohammed; Pouzalgues, Romain; Garrigues, Alain; Delbos, Christophe; Azaïs, Bruno
2016-09-01
This research work is devoted to the experimental and theoretical analysis of air plasmas induced by multi-MeV pulsed X-ray for a large pressure range of humid air background gas varying from 20 mbar to atmospheric pressure. The time evolution of the electron density of the air plasma is determined by electromagnetic wave absorption measurements. The measurements have uncertainties of about ±30%, taking into account the precision of the dose measurement and also the shot to shot fluctuations of the generator. The experimental electron density is obtained by comparing the measurements of the transmitted microwave signals to the calculated ones. The calculations need the knowledge of the time evolution of the electron mean energy, which is determined by a chemical kinetic model based on a reaction scheme involving 39 species interacting following 265 reactions. During the X-ray pulse, a good agreement is obtained between time evolution of the electron density obtained from absorption measurements and calculations based on the kinetic model. The relative deviation on the maximum electron density and the corresponding plasma frequency is always lower than 10%. The maximum electron density varies from 4 × 1011 to 3.5 × 1013 cm-3 between 30 mbar to atmospheric pressure, while the peak of the electron mean energy decreases from 5.64 eV to 4.27 eV in the same pressure range.
van Steveninck, A L; Schoemaker, H C; den Hartigh, J; Pieters, M S; Breimer, D D; Cohen, A F
1994-05-01
To evaluate the long-term reproducibility of pharmacokinetic, pharmacodynamic, and concentration-effect parameters after intravenous administration of temazepam. Nine healthy volunteers were studied. Temazepam, 0.4 mg/kg, was infused intravenously for 30 minutes on two occasions 6 months apart. Venous plasma concentrations of temazepam were measured by HPLC in samples obtained between 0 and 24 hours. Pharmacodynamic effects were evaluated up to 8 hours for saccadic peak velocity and electroencephalogram (EEG) beta amplitudes. Subjects' state and trait anxiety were assessed by use of the Spielberger anxiety inventory. Significant correlations between occasions were found for area under the plasma concentration-time curve (AUC) values (r = 0.91; p < 0.01) but not for maximum concentration and half-life. Significant correlations were also found for area under the effect-time curve (AUEC) values of peak velocity (r = 0.88; p < 0.01) but not for peak velocity (r = 0.48; p > 0.05). Significant differences between the slopes of concentration effect plots on different occasions were observed in two subjects for EEG beta and in three subjects for peak velocity, with one subject showing a similar change for both parameters. Trait anxiety scores were higher on the first occasion (33 +/- 7) than on the second occasion (29 +/- 7; p < 0.01). A negative correlation was found between trait anxiety scores and the slopes of concentration-effect plots for peak velocity (r = -0.63; p < 0.01). For AUC and AUEC values the results indicate a reasonable long-term reproducibility of differences between subjects in the pharmacokinetics and pharmacodynamics of temazepam. However, there were limitations to the predictive value of derived concentration-effect parameters.
An ISEE/Whistler model of equatorial electron density in the magnetosphere
NASA Technical Reports Server (NTRS)
Carpenter, D. L.; Anderson, R. R.
1992-01-01
Attention is given to an empirical model of equatorial electron density in the magnetosphere covering the L range 2.25-8. Although the model is primarily intended for application to the local time interval 00-15 MLT, a way to extend the model to the 15-24-MLT period is presented. The model describes, in piecewise fashion, the 'saturated' plasmasphere, the region of steep plasmapause gradients, and the plasma trough. Within the plasmasphere the model profile can be expressed as logne - Sigma-xi, where x1 = -0.3145L + 3.9043 is the principal or 'reference' term, and additional terms account for: a solar cycle variation with a peak at solar maximum; an annual variation with a December maximum; and a semiannual variation with equinoctial maxima.
NASA Technical Reports Server (NTRS)
Convertino, V. A.
1998-01-01
To test the hypothesis that the magnitude of reduction in plasma volume and work capacity following exposure to simulated microgravity is dependent on the initial level of aerobic fitness, peak oxygen uptake (VO2peak) was measured in a group of physically fit subjects and compared with VO2peak in a group of relatively unfit subjects before and after 10 days of continuous 6 degrees head-down tilt (HDT). Ten fit subjects (40 +/- 2 year) with mean +/- SE VO2peak = 48.9 +/- 1.7 mL kg-1 min-1 were matched for age, height, and lean body weight with 10 unfit subjects (VO2peak = 37.7 +/- 1.6 mL kg-1 min-1). Before and after HDT, plasma, blood, and red cell volumes and body composition were measured and all subjects underwent a graded supine cycle ergometer test to determine VO2peak period needed. Reduced VO2peak in fit subjects (-16.2%) was greater than that of unfit subjects (-6.1%). Similarly, reductions in plasma (-18.3%) and blood volumes (-16.0%) in fit subjects were larger than those of unfit subjects (blood volume = -5.6%; plasma volume = -6.6%). Reduced plasma volume was associated with greater negative body fluid balance during the initial 24 h of HDT in the fit group (912 +/- 154 mL) compared with unfit subjects (453 +/- 200 mL). The percentage change for VO2peak correlated with percentage change in plasma volume (r = +0.79). Following exposure to simulated microgravity, fit subjects demonstrated larger reductions in VO2peak than unfit subjects which was associated with larger reductions in plasma and blood volume. These data suggest that the magnitude of physical deconditioning induced by exposure to microgravity without intervention of countermeasures was influenced by the initial fitness of the subjects.
NASA Astrophysics Data System (ADS)
Cortázar, O. D.; Megía-Macías, A.; Vizcaíno-de-Julián, A.
2012-10-01
An experimental study of temperature and density evolution during breakdown in off-resonance ECR hydrogen plasma is presented. Under square 2.45 GHz microwave excitation pulses with a frequency of 50 Hz and relative high microwave power, unexpected transient temperature peaks that reach 18 eV during 20 μs are reported at very beginning of plasma breakdown. Decays of such peaks reach final stable temperatures of 5 eV at flat top microwave excitation pulse. Evidence of interplay between incoming power and duty cycle giving different kind of plasma parameters evolutions engaged to microwave coupling times is observed. Under relative high power conditions where short microwave coupling times are recorded, high temperature peaks are measured. However, for lower incoming powers and longer coupling times, temperature evolves gradually to a higher final temperature without peaking. On the other hand, the early instant where temperature peaks are observed also suggest a possible connection with preglow processes during breakdown in ECRIS plasmas.
Plasma dispositions and concentrations of ivermectin in eggs following treatment of laying hens.
Cirak, V Y; Aksit, D; Cihan, H; Gokbulut, C
2018-05-01
To determine the plasma disposition and concentrations of ivermectin (IVM) in eggs produced by laying hens following S/C, oral and I/V administration. Twenty-four laying hens, aged 37 weeks and weighing 1.73 (SD 0.12) kg were allocated to three groups of eight birds. The injectable formulation of IVM was administered either orally, S/C, or I/V, at a dose of 0.2 mg/kg liveweight, following dilution (1:5, v/v) with propylene glycol. Heparinised blood samples were collected at various times between 0.25 hours and 20 days after drug administration. Eggs produced by hens were also collected daily throughout the study period. Samples of plasma and homogenised egg were analysed using HPLC. Maximum concentrations of IVM in plasma and mean residence time of IVM were lower after oral (10.2 (SD 7.2) ng/mL and 0.38 (SD 0.14) days, respectively) than after S/C (82.9 (SD 12.4) ng/mL and 1.05 (SD 0.24) days, respectively) administration (p<0.01). The time to maximum concentration and elimination half-life were shorter following oral (0.14 (SD 0.04) and 0.23 (SD 0.11) days, respectively) than S/C (0.25 (SD 0.00) and 1.45 (SD 0.45) days, respectively) administration (p<0.01). IVM was first detected in eggs 2 days after treatment in all groups and was detected until 8 days after oral and I/V administration, and until 15 days after S/C administration. Peak concentrations of IVM were 15.7, 23.3 and 1.9 µg/kg, observed 2, 5 and 4 days after I/V, S/C and oral administration, respectively. The low plasma bioavailability of IVM observed after oral administration in laying hens could result in lower efficacy or subtherapeutic plasma concentrations, which may promote the development of parasitic drug resistance. Due to high IVM residues in eggs compared to the maximum residue limits for other food-producing animal species, a withdrawal period should be necessary for eggs after IVM treatment in laying hens.
Evidence of L-mode electromagnetic wave pumping of ionospheric plasma near geomagnetic zenith
NASA Astrophysics Data System (ADS)
Leyser, Thomas B.; James, H. Gordon; Gustavsson, Björn; Rietveld, Michael T.
2018-02-01
The response of ionospheric plasma to pumping by powerful HF (high frequency) electromagnetic waves transmitted from the ground into the ionosphere is the strongest in the direction of geomagnetic zenith. We present experimental results from transmitting a left-handed circularly polarized HF beam from the EISCAT (European Incoherent SCATter association) Heating facility in magnetic zenith. The CASSIOPE (CAScade, Smallsat and IOnospheric Polar Explorer) spacecraft in the topside ionosphere above the F-region density peak detected transionospheric pump radiation, although the pump frequency was below the maximum ionospheric plasma frequency. The pump wave is deduced to arrive at CASSIOPE through L-mode propagation and associated double (O to Z, Z to O) conversion in pump-induced radio windows. L-mode propagation allows the pump wave to reach higher plasma densities and higher ionospheric altitudes than O-mode propagation so that a pump wave in the L-mode can facilitate excitation of upper hybrid phenomena localized in density depletions in a larger altitude range. L-mode propagation is therefore suggested to be important in explaining the magnetic zenith effect.
Plasma bupivacaine concentrations following orbital injections in cats.
Shilo-Benjamini, Yael; Pypendop, Bruno H; Newbold, Georgina; Pascoe, Peter J
2017-01-01
To determine plasma bupivacaine concentrations after retrobulbar or peribulbar injection of bupivacaine in cats. Randomized, crossover, experimental trial with a 2 week washout period. Six adult healthy cats, aged 1-2 years, weighing 4.6 ± 0.7 kg. Cats were sedated by intramuscular injection of dexmedetomidine (36-56 μg kg -1 ) and were administered a retrobulbar injection of bupivacaine (0.75 mL, 0.5%; 3.75 mg) and iopamidol (0.25 mL), or a peribulbar injection of bupivacaine (1.5 mL, 0.5%; 7.5 mg), iopamidol (0.5 mL) and 0.9% saline (1 mL) via a dorsomedial approach. Blood (2 mL) was collected before and at 5, 10, 15, 22, 30, 45, 60, 120, 240 and 480 minutes after bupivacaine injection. Atipamezole was administered approximately 30 minutes after bupivacaine injection. Plasma bupivacaine and 3-hydroxybupivacaine concentrations were determined using liquid chromatography-mass spectrometry. Bupivacaine maximum plasma concentration (C max ) and time to C max (T max ) were determined from the data. The bupivacaine median (range) C max and T max were 1.4 (0.9-2.5) μg mL -1 and 17 (4-60) minutes, and 1.7 (1.0-2.4) μg mL -1 , and 28 (8-49) minutes, for retrobulbar and peribulbar injections, respectively. In both treatments the 3-hydroxybupivacaine peak concentration was 0.05-0.21 μg mL -1 . In healthy cats, at doses up to 2 mg kg -1 , bupivacaine peak plasma concentrations were approximately half that reported to cause arrhythmias or convulsive electroencephalogram (EEG) activity in cats, and about one-sixth of that required to produce hypotension. Copyright © 2016 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.
Analysis of extreme ultraviolet spectra from laser produced rhenium plasmas
NASA Astrophysics Data System (ADS)
Wu, Tao; Higashiguchi, Takeshi; Li, Bowen; Suzuki, Yuhei; Arai, Goki; Dinh, Thanh-Hung; Dunne, Padraig; O'Reilly, Fergal; Sokell, Emma; Liu, Luning; O'Sullivan, Gerry
2015-08-01
Extreme ultraviolet spectra of highly-charged rhenium ions were observed in the 1-7 nm region using two Nd:YAG lasers with pulse lengths of 150 ps and 10 ns, respectively, operating at a number of laser power densities. The maximum focused peak power density was 2.6 × 1014 W cm-2 for the former and 5.5 × 1012 W cm-2 for the latter. The Cowan suite of atomic structure codes and unresolved transition array (UTA) approach were used to calculate and interpret the emission properties of the different spectra obtained. The results show that n = 4-n = 4 and n = 4-n = 5 UTAs lead to two intense quasi-continuous emission bands in the 4.3-6.3 nm and 1.5-4.3 nm spectral regions. As a result of the different ion stage distributions in the plasmas induced by ps and ns laser irradiation the 1.5-4.3 nm UTA peak moves to shorter wavelength in the ps laser produced plasma spectra. For the ns spectrum, the most populated ion stage during the lifetime of this plasma that could be identified from the n = 4-n = 5 transitions was Re23+ while for the ps plasma the presence of significantly higher stages was demonstrated. For the n = 4-n = 4 4p64dN-4p54dN+1 + 4p64dN-14f transitions, the 4d-4f transitions contribute mainly in the most intense 4.7-5.5 nm region while the 4p-4d subgroup gives rise to a weaker feature in the 4.3-4.7 nm region. A number of previously unidentified spectral features produced by n = 4-n = 5 transitions in the spectra of Re XVI to Re XXXIX are identified.
Plasma potassium and diurnal cyclic potassium excretion in the rat.
Rabinowitz, L; Berlin, R; Yamauchi, H
1987-12-01
The relation of the plasma potassium concentration to the daily cyclic variation in potassium excretion was examined in undisturbed, unanesthetized male Sprague-Dawley rats maintained on a liquid diet in a 12-h light-dark environment. Potassium excretion increased from a light-phase minimum of 16 mu eq/h to a peak of 256 mu eq/h 3 h after the beginning of the dark phase. Plasma potassium concentration in arterial blood, sampled in rats at 90-min intervals during these changes in potassium excretion, showed no significant change and was in the range 4.50-4.99 meq/liter. In adrenalectomized rats receiving aldosterone and dexamethasone at constant basal rates by implanted pumps, the daily cycle of potassium excretion was the same as in the intact rats, and plasma potassium was not significantly different when measured at the time of minimum and maximum rates of potassium excretion (4.79 +/- 0.42 vs 5.16 +/- 0.47 meq/liter, mean +/- SD). These results indicate that plasma potassium concentration is not the efferent factor controlling diurnal cyclic changes in potassium excretion in adrenal intact rats and may not be the only significant factor in adrenalectomized-steroid replaced rats.
Morphology of equatorial plasma bubbles during low and high solar activity years over Indian sector
NASA Astrophysics Data System (ADS)
Kumar, Sanjay
2017-05-01
In the present study, slant total electron content (STEC) data computed from ground based GPS measurements over Hyderabad (Geog. Lat. 17.41° N, geog. long. 78.55° E, mag. lat. 08.81° N) and two close stations at Bangalore (Geog. Lat. 13.02°/13.03° N, geog. long. 77.57°/77.51° E, mag. lat. 04.53°/04.55° N) in Indian region during 2007-2012, have been used to study the occurrences and characteristics of equatorial plasma bubbles (EPBs). The analysis found maximum EPB occurrences during the equinoctial months and minimum during the December solstice throughout 2007-2012 except during the solar minimum years in 2007-2009. During 2007-2009, the maximum EPB occurrences were observed in June solstice which could not be predicted by the model proposed by Tsunoda (J. Geophys. Res., 90:447-456, 1985). The equinox maximum in EPB occurrences for high solar activity years could be caused by the vertical F-layer drift due to pre-reversal electric field (PRE), and expected to be maximum when day-night terminator aligns with the magnetic meridian i.e. during the equinox months whereas maximum occurrences during the solstice months of solar minimum could be caused by the seed perturbation in plasma density induced by gravity waves from tropospheric origins. Generally EPB occurrences are found to be more prominent during nighttime hours (2000-2400 hours) than the daytime hours. Peak in EPB occurrences is in early night for high solar activity years whereas same is late night for low solar activity. The day and nighttime EPB occurrences have been analyzed and found to vary in accordance with solar activity with an annual correlation coefficient (R) of ˜0.99 with F_{10.7} cm solar Flux. Additionally, solar activity influence on EPB occurrences is seasonal dependent with a maximum influence during the equinox season (R=0.88) and a minimum during winter season (R =0.73). The solar activity influences on EPB occurrences are found in agreement with the previous works reported in the Brazilian, African-Asian and Pacific longitudes sector but different than that in Atlantic sector.
Mastalerz, Lucyna; Celińska-Lӧwenhoff, Magdalena; Krawiec, Piotr; Batko, Bogdan; Tłustochowicz, Witold; Undas, Anetta
2015-01-01
Given reports on the increased prevalence of thromboembolic incidents in patients with eosinophilic granulomatosis with polyangiitis (EGPA; Churg-Strauss syndrome), we investigated whether fibrin clot properties are unfavorably altered in EGPA. Ex vivo plasma fibrin clot characteristics, including clot permeability, turbidimetry and efficiency of fibrinolysis using two assays, were investigated in 34 consecutive patients with remission in EGPA according to the Birmingham Vasculitis Activity Score version 3 (23 female, 11 male), aged 48 (range, 21-80) years. The control group comprised 34 age- and sex- matched volunteers. Compared with controls, patients with EGPA were characterized by denser fiber clots (estimated pore size, Ks, 7.30±0.93 vs 10.14±1.07 10-9 cm2), faster fibrin polymerization (lag phase in a turbidimetric curve, 41.8±3.6 vs 47.4±2.9 s), thicker fibrin fibers (maximum absorbance, ΔAbs, 0.87±0.09 vs 0.72±0.07), higher maximum levels of D-dimer released from clots (DDmax 4.10±0.46 vs 3.54±0.35 mg/L), and prolonged clot lysis time (t50%; 9.50±1.45 vs 7.56±0.87 min); all p<0.0001. Scanning electron microscopy images confirmed denser plasma fibrin networks composed of thinner fibers formed in EGPA. Antineutrophil cytoplasmic antibody status and C-reactive protein did not affect clot variables. Multivariate analysis adjusted for fibrinogen showed that Ks was predicted by eosinophil count, peak thrombin generation, factor VIII, and soluble CD40 ligand, whereas eosinophil count, peak thrombin generation and antiplasmin predicted t50%. This study is the first to show that EGPA is associated with prothrombotic plasma fibrin clot phenotype, which may contribute to thromboembolic manifestations reported in this disease.
Mastalerz, Lucyna; Celińska-Lӧwenhoff, Magdalena; Krawiec, Piotr; Batko, Bogdan; Tłustochowicz, Witold; Undas, Anetta
2015-01-01
Objectives Given reports on the increased prevalence of thromboembolic incidents in patients with eosinophilic granulomatosis with polyangiitis (EGPA; Churg-Strauss syndrome), we investigated whether fibrin clot properties are unfavorably altered in EGPA. Methods Ex vivo plasma fibrin clot characteristics, including clot permeability, turbidimetry and efficiency of fibrinolysis using two assays, were investigated in 34 consecutive patients with remission in EGPA according to the Birmingham Vasculitis Activity Score version 3 (23 female, 11 male), aged 48 (range, 21–80) years. The control group comprised 34 age- and sex- matched volunteers. Results Compared with controls, patients with EGPA were characterized by denser fiber clots (estimated pore size, Ks, 7.30±0.93 vs 10.14±1.07 10−9 cm2), faster fibrin polymerization (lag phase in a turbidimetric curve, 41.8±3.6 vs 47.4±2.9 s), thicker fibrin fibers (maximum absorbance, ΔAbs, 0.87±0.09 vs 0.72±0.07), higher maximum levels of D-dimer released from clots (DDmax 4.10±0.46 vs 3.54±0.35 mg/L), and prolonged clot lysis time (t50%; 9.50±1.45 vs 7.56±0.87 min); all p<0.0001. Scanning electron microscopy images confirmed denser plasma fibrin networks composed of thinner fibers formed in EGPA. Antineutrophil cytoplasmic antibody status and C-reactive protein did not affect clot variables. Multivariate analysis adjusted for fibrinogen showed that Ks was predicted by eosinophil count, peak thrombin generation, factor VIII, and soluble CD40 ligand, whereas eosinophil count, peak thrombin generation and antiplasmin predicted t50%. Conclusion This study is the first to show that EGPA is associated with prothrombotic plasma fibrin clot phenotype, which may contribute to thromboembolic manifestations reported in this disease. PMID:26540111
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brummer, Gordie, E-mail: gbrummer@bu.edu; Photonics Center, Boston University, Boston, Massachusetts 02215; Nothern, Denis
Distributed Bragg reflectors (DBRs) with peak reflectivity at approximately 280 nm, based on compositionally graded Al{sub x}Ga{sub 1−x}N alloys, were grown on 6H-SiC substrates by plasma-assisted molecular beam epitaxy. DBRs with square, sinusoidal, triangular, and sawtooth composition profiles were designed with the transfer matrix method. The crystal structure of these DBRs was studied with high-resolution x-ray diffraction of the (1{sup ¯}015) reciprocal lattice point. The periodicity of the DBR profiles was confirmed with cross-sectional Z-contrast scanning transmission electron microscopy. The peak reflectance of these DBRs with 15.5 periods varies from 77% to 56% with corresponding full width at half maximum ofmore » 17–14 nm. Coupled mode analysis was used to explain the dependence of the reflectivity characteristics on the profile of the graded composition.« less
Longitudinal structure of the equatorial ionosphere: Time evolution of the four-peaked EIA structure
NASA Astrophysics Data System (ADS)
Lin, C. H.; Hsiao, C. C.; Liu, J. Y.; Liu, C. H.
2007-12-01
Longitudinal structure of the equatorial ionosphere during the 24 h local time period is observed by the FORMOSAT-3/COSMIC (F3/C) satellite constellation. By binning the F3/C radio occultation observations during September and October 2006, global ionospheric total electron content (TEC) maps at a constant local time map (local time TEC map, referred as LT map) can be obtained to monitor the development and subsidence of the four-peaked longitudinal structure of the equatorial ionosphere. From LT maps, the four-peaked structure starts to develop at 0800-1000 LT and becomes most prominent at 1200-1600 LT. The longitudinal structure starts to subside after 2200-2400 LT and becomes indiscernible after 0400-0600 LT. In addition to TEC, ionospheric peak altitude also shows a four-peaked longitudinal structure with variation very similar to TEC during daytime. The four-peaked structure of the ionospheric peak altitude is indiscernible at night. With global local time maps of ionospheric TEC and peak altitude, we compare temporal variations of the longitudinal structure with variations of E × B drift from the empirical model. Our results indicate that the observations are consistent with the hypothesis that the four-peaked longitudinal structure is caused by the equatorial plasma fountain modulated by the E3 nonmigrating tide. Additionally, the four maximum regions show a tendency of moving eastward with propagation velocity of several 10 s m/s.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakamura, Kei; Mao, Hann-Shin; Gonsalves, Anthony J.
A laser system producing controllable and stable pulses with high power and ultrashort duration at high repetition rate is a key component of a high energy laser-plasma accelerator (LPA). Precise characterization and control of laser properties are essential to understanding laser-plasma interactions required to build a 10-GeV class LPA. This study discusses the diagnostics, control and performance parameters of a 1 Hz, 1 petawatt (PW) class laser at the Berkeley Lab Laser Accelerator (BELLA) facility. The BELLA PW laser provided up to 46 J on target with a 1% level energy fluctuation and 1.3-μrad pointing stability. The spatial profile wasmore » measured and optimized by using a camera, wavefront sensor, and deformable mirror (ILAO system). The focus waist was measured to be r 0 = 53 μm and the fraction of energy within the circular area defined by the first minimum of the diffraction pattern (r = 67 μm) was 0.75. The temporal profile was controlled via the angle of incidence on a stretcher and a compressor, as well as an acousto-optic programmable dispersive. The temporal pulse shape was measured to be about 33 fs in full width at half maximum (WIZZLER and GRENOUILLE diagnostics). In order to accurately evaluate peak intensity, the energy-normalized peak fluence, and energy-normalized peak power were analyzed for the measured spatial and temporal mode profiles, and were found to be 15 kJ/(cm 2 J) with 6% fluctuation (standard deviation) and 25 TW/J with 5% fluctuation for 46-J on-target energy, respectively. This yielded a peak power of 1.2 PW and a peak intensity of 17×10 18 W/cm 2 with 8% fluctuation. A method to model the pulse shape for arbitrary compressor grating distance with high accuracy was developed. The pulse contrast above the amplified spontaneous emission pedestal was measured by SEQUOIA and found to be better than 10 9. The first order spatiotemporal couplings (STCs) were measured with GRENOUILLE, and a simulation of the pulse's evolution at the vicinity of the target was presented. A maximum pulse front tilt angle of less than 7 mrad was achieved. The reduction of the peak power caused by the first order STCs was estimated to be less than 1%. Finally, the capabilities described in this paper are essential for generation of high quality electron beams.« less
Nakamura, Kei; Mao, Hann-Shin; Gonsalves, Anthony J.; ...
2017-05-25
A laser system producing controllable and stable pulses with high power and ultrashort duration at high repetition rate is a key component of a high energy laser-plasma accelerator (LPA). Precise characterization and control of laser properties are essential to understanding laser-plasma interactions required to build a 10-GeV class LPA. This study discusses the diagnostics, control and performance parameters of a 1 Hz, 1 petawatt (PW) class laser at the Berkeley Lab Laser Accelerator (BELLA) facility. The BELLA PW laser provided up to 46 J on target with a 1% level energy fluctuation and 1.3-μrad pointing stability. The spatial profile wasmore » measured and optimized by using a camera, wavefront sensor, and deformable mirror (ILAO system). The focus waist was measured to be r 0 = 53 μm and the fraction of energy within the circular area defined by the first minimum of the diffraction pattern (r = 67 μm) was 0.75. The temporal profile was controlled via the angle of incidence on a stretcher and a compressor, as well as an acousto-optic programmable dispersive. The temporal pulse shape was measured to be about 33 fs in full width at half maximum (WIZZLER and GRENOUILLE diagnostics). In order to accurately evaluate peak intensity, the energy-normalized peak fluence, and energy-normalized peak power were analyzed for the measured spatial and temporal mode profiles, and were found to be 15 kJ/(cm 2 J) with 6% fluctuation (standard deviation) and 25 TW/J with 5% fluctuation for 46-J on-target energy, respectively. This yielded a peak power of 1.2 PW and a peak intensity of 17×10 18 W/cm 2 with 8% fluctuation. A method to model the pulse shape for arbitrary compressor grating distance with high accuracy was developed. The pulse contrast above the amplified spontaneous emission pedestal was measured by SEQUOIA and found to be better than 10 9. The first order spatiotemporal couplings (STCs) were measured with GRENOUILLE, and a simulation of the pulse's evolution at the vicinity of the target was presented. A maximum pulse front tilt angle of less than 7 mrad was achieved. The reduction of the peak power caused by the first order STCs was estimated to be less than 1%. Finally, the capabilities described in this paper are essential for generation of high quality electron beams.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakamura, K; Mao, HS; Gonsalves, AJ
2017-08-01
© 2017 IEEE. A laser system producing controllable and stable pulses with high power and ultrashort duration at high repetition rate is a key component of a high energy laser-plasma accelerator (LPA). Precise characterization and control of laser properties are essential to understanding laser-plasma interactions required to build a 10-GeV class LPA. This paper discusses the diagnostics, control and performance parameters of a 1 Hz, 1 petawatt (PW) class laser at the Berkeley Lab Laser Accelerator (BELLA) facility. The BELLA PW laser provided up to 46 J on target with a 1% level energy fluctuation and 1.3-μrad pointing stability. Themore » spatial profile was measured and optimized by using a camera, wavefront sensor, and deformable mirror (ILAO system). The focus waist was measured to be r 0 = 53 μm and the fraction of energy within the circular area defined by the first minimum of the diffraction pattern (r = 67 μm) was 0.75. The temporal profile was controlled via the angle of incidence on a stretcher and a compressor, as well as an acousto-optic programmable dispersive. The temporal pulse shape was measured to be about 33 fs in full width at half maximum (WIZZLER and GRENOUILLE diagnostics). In order to accurately evaluate peak intensity, the energy-normalized peak fluence, and energy-normalized peak power were analyzed for the measured spatial and temporal mode profiles, and were found to be 15 kJ/(cm 2 J) with 6% fluctuation (standard deviation) and 25 TW/J with 5% fluctuation for 46-J on-target energy, respectively. This yielded a peak power of 1.2 PW and a peak intensity of 17×10 18 W/cm 2 with 8% fluctuation. A method to model the pulse shape for arbitrary compressor grating distance with high accuracy was developed. The pulse contrast above the amplified spontaneous emission pedestal was measured by SEQUOIA and found to be better than 10 9 . The first order spatiotemporal couplings (STCs) were measured with GRENOUILLE, and a simulation of the pulse's evolution at the vicinity of the target was presented. A maximum pulse front tilt angle of less than 7 mrad was achieved. The reduction of the peak power caused by the first order STCs was estimated to be less than 1%. The capabilities described in thispaper are essential for generation of high quality electron beams.« less
Waterfall, J. F.
1989-01-01
1 Cilazapril is the monoethyl ester prodrug form of the di-acid cilazaprilat, a new angiotensin converting enzyme (ACE) inhibitor. Cilazaprilat has an IC50 of 1.9 nM as an inhibitor of rabbit lung ACE in vitro making it one of the most potent ACE inhibitors currently available. Studies on a wide range of other enzymes show that the inhibition is highly specific. 2 An oral dose of 0.1 mg kg-1 cilazapril evoked the same maximum degree of plasma ACE inhibition (∼76%) in the rat as 0.25 mg kg-1 enalapril. Cilazapril (0.25 mg kg-1 p.o.) inhibited plasma ACE by > 95%. The rate of recovery of ACE activity was slower with cilazapril (5-6% h-1) than with enalapril (10% h-1). 3 In anaesthetised rats cilazaprilat was equipotent with ramiprilat and slightly more potent (1.5×) than enalaprilat as an inhibitor of the angiotensin I pressor response. 4 Following oral administration to conscious rats and intravenous administration to anaesthetised dogs, cilazapril was 2-4.5× more potent than enalapril as an ACE inhibitor. 5 In cats cilazapril (0.1 and 0.3 mg kg-1 p.o.) dose dependently decreased plasma ACE activity and the angiotensin pressor response. Peak effects occurred at 2 h after dosing and plasma ACE inhibition was maintained at ≥ 50% for up to 18 h. Mean arterial pressure was also decreased dose dependently with a peak effect at 3-4 h. 6 Daily oral dosing of cilazapril (30 mg kg-1 p.o.) to spontaneously hypertensive rats evoked a progressive and prolonged (24 h) antihypertensive response with a maximum decrease in systolic blood pressure of 110 mm Hg. 7 Cilazapril (10 mg kg-1 p.o. twice daily for 3.5 days) progressively decreased blood pressure in volume depleted renal hypertensive dogs. The maximum fall in systolic pressure was 39 ± 6 mm Hg. 8 Haemodynamic studies in open chest anaesthetised dogs showed that the hypotensive response to intravenous cilazapril was accompanied by a reduction in total peripheral resistance. Small decreases in cardiac output and myocardial contractile force were seen at high doses. 9 Cilazapril had no adverse effect on cardiovascular reflexes. There was no impairment of the baroreflex in rats. Exercise-induced tachycardia and pressor responses in conscious cats were unchanged. 10 Cilazapril is exceptionally well absorbed by the oral route (98% in rats). PMID:2527528
Excimer laser produced plasmas in copper wire targets and water droplets
NASA Technical Reports Server (NTRS)
Song, Kyo-Dong; Alexander, D. R.
1994-01-01
Elastically scattered incident radiation (ESIR) from a copper wire target illuminated by a KrF laser pulse at lambda = 248 nm shows a dinstinct two-peak structure which is dependent on the incident energy. The time required to reach the critical electron density (n(sub c) approximately = 1.8 x 10(exp 22) electrons/cu cm) is estimated at 11 ns based on experimental results. Detailed ESIR characteristics for water have been reported previously by the authors. Initiation of the broadband emission for copper plasma begins at 6.5 +/- 1.45 ns after the arrival of the laser pulse. However, the broadband emission occurs at 11 +/- 0.36 ns for water. For a diatomic substance such as water, the electron energy rapidly dissipates due to dissociation of water molecules, which is absent in a monatomic species such as copper. When the energy falls below the excitation energy of the lowest electron state for water, it becomes a subexcitation electron. Lifetimes of the subexcited electrons to the vibrational states are estimated to be of the order of 10(exp -9) s. In addition, the ionization potential of copper (440-530 nm) is approximately 6 eV, which is about two times smaller than the 13 eV ionization potential reported for water. The higher ionization potential contributes to the longer observed delay time for plasma formation in water. After initiation, a longer time is required for copper plasma to reach its peak value. This time delay in reaching the maximum intensity is attributed to the energy loss during the interband transition in copper.
Plasma spectrum peak extraction algorithm of laser film damage
NASA Astrophysics Data System (ADS)
Zhao, Dan; Su, Jun-hong; Xu, Jun-qi
2012-10-01
The plasma spectrometry is an emerging method to distinguish the thin-film laser damage. Laser irradiation film surface occurrence of flash, using the spectrometer receives the flash spectrum, extracting the spectral peak, and by means of the spectra of the thin-film materials and the atmosphere has determine the difference, as a standard to determine the film damage. Plasma spectrometry can eliminate the miscarriage of justice which caused by atmospheric flashes, and distinguish high accuracy. Plasma spectra extraction algorithm is the key technology of Plasma spectrometry. Firstly, data de noising and smoothing filter is introduced in this paper, and then during the peak is detecting, the data packet is proposed, and this method can increase the stability and accuracy of the spectral peak recognition. Such algorithm makes simultaneous measurement of Plasma spectrometry to detect thin film laser damage, and greatly improves work efficiency.
Zhang, Yaqing; Zhang, Zunjian; Song, Rui
2018-06-01
Rhubarb-Radix scutellariae is a classic herb pair, which is commonly used to clear away heat and toxin in clinic. The aim of this study was to investigate the influence of compatibility of Rhubarb and Radix scutellariae on the pharmacokinetic behaviors of anthraquinones and flavonoids in rat plasma. Eighteen rats were randomly divided into three groups, and were orally administered Rhubarb and/or Radix scutellariae extracts. A sensitive and rapid UPLC-MS/MS method was developed and validated to determine the concentrations of baicalin, baicalein, wogonside, wogonin, rhein, and emodin in rat plasma. The concentrations of phase II conjugates of flavonoid aglycones and anthraquinone aglycones were also determined after hydrolyzing the plasma with sulfatase. Compared with administration of Radix scutellariae alone, co-administration of Rhubarb significantly decreased the first maximum plasma concentration (C max1 ) of baicalin, wogonside, and the phase II conjugates of baicalein, wogonin to 46.40, 61.27, 41.49, and 20.50%, respectively. The area under the plasma concentration-time curve from time zero to infinity (AUC 0-∞ ) was significantly decreased from 82.60 ± 20.22 to 51.91 ± 7.46 μM·h for rhein and 276.83 ± 98.02 to 175.42 ± 86.82 μM·h for the phase II conjugates of wogonin after compatibility. The time to reach the first maximum plasma concentration (T max1 ) of anthraquinones was shortened and the second peak of anthraquinones disappeared after compatibility. Compatibility of Rhubarb and Radix scutellariae can significantly affect the pharmacokinetic behaviors of characteristic constituents of the two herbs. The cause of these pharmacokinetic differences was further discussed combined with the in vivo ADME (absorption, disposition, metabolism, and excretion) processes of anthraquinones and flavonoids.
Plasma appearance and correlation between coffee and green tea metabolites in human subjects.
Renouf, Mathieu; Guy, Philippe; Marmet, Cynthia; Longet, Karin; Fraering, Anne-Lise; Moulin, Julie; Barron, Denis; Dionisi, Fabiola; Cavin, Christophe; Steiling, Heike; Williamson, Gary
2010-12-01
Coffee and green tea are two of the most widely consumed hot beverages in the world. Their respective bioavailability has been studied separately, but absorption of their respective bioactive phenolics has not been compared. In a randomised cross-over design, nine healthy subjects drank instant coffee and green tea. Blood samples were collected over 12 h and at 24 h to assess return to baseline. After green tea consumption, (-)-epigallocatechin (EGC) was the major catechin, appearing rapidly in the plasma; (-)-EGC gallate (EGCg) and (-)-epicatechin (EC) were also present, but (-)-EC gallate and C were not detected. Dihydroferulic acid and dihydrocaffeic acid were the major metabolites that appeared after coffee consumption with a long time needed to reach maximum plasma concentration, suggesting metabolism and absorption in the colon. Other phenolic acid equivalents (caffeic acid (CA), ferulic acid (FA) and isoferulic acid (iFA)) were detected earlier, and they peaked at lower concentrations. Summations of the plasma area under the curves (AUC) for the measured metabolites showed 1.7-fold more coffee-derived phenolic acids than green tea-derived catechins (P = 0.0014). Furthermore, we found a significant correlation between coffee metabolites based on AUC. Inter-individual differences were observed, but individuals with a high level of CA also showed a correspondingly high level of FA. However, no such correlation was observed between the tea catechins and coffee phenolic acids. Correlation between AUC and maximum plasma concentration was also significant for CA, FA and iFA and for EGCg. This implies that the mechanisms of absorption for these two classes of compounds are different, and that a high absorber of phenolic acids is not necessarily a high absorber of catechins.
30 CFR 816.67 - Use of explosives: Control of adverse effects.
Code of Federal Regulations, 2013 CFR
2013-07-01
... established in accordance with either the maximum peak-particle-velocity limits of paragraph (d)(2), the... in the blasting plan and approved by the regulatory authority. (2) Maximum peak particle velocity. (i... (D), from the blasting site, in feet Maximum allowable peak particle velocity (V max) for ground...
30 CFR 816.67 - Use of explosives: Control of adverse effects.
Code of Federal Regulations, 2014 CFR
2014-07-01
... established in accordance with either the maximum peak-particle-velocity limits of paragraph (d)(2), the... in the blasting plan and approved by the regulatory authority. (2) Maximum peak particle velocity. (i... (D), from the blasting site, in feet Maximum allowable peak particle velocity (V max) for ground...
30 CFR 816.67 - Use of explosives: Control of adverse effects.
Code of Federal Regulations, 2010 CFR
2010-07-01
... established in accordance with either the maximum peak-particle-velocity limits of paragraph (d)(2), the... in the blasting plan and approved by the regulatory authority. (2) Maximum peak particle velocity. (i... (D), from the blasting site, in feet Maximum allowable peak particle velocity (V max) for ground...
30 CFR 816.67 - Use of explosives: Control of adverse effects.
Code of Federal Regulations, 2012 CFR
2012-07-01
... established in accordance with either the maximum peak-particle-velocity limits of paragraph (d)(2), the... in the blasting plan and approved by the regulatory authority. (2) Maximum peak particle velocity. (i... (D), from the blasting site, in feet Maximum allowable peak particle velocity (V max) for ground...
30 CFR 816.67 - Use of explosives: Control of adverse effects.
Code of Federal Regulations, 2011 CFR
2011-07-01
... established in accordance with either the maximum peak-particle-velocity limits of paragraph (d)(2), the... in the blasting plan and approved by the regulatory authority. (2) Maximum peak particle velocity. (i... (D), from the blasting site, in feet Maximum allowable peak particle velocity (V max) for ground...
Isotope effects of trapped electron modes in the presence of impurities in tokamak plasmas
NASA Astrophysics Data System (ADS)
Shen, Yong; Dong, J. Q.; Sun, A. P.; Qu, H. P.; Lu, G. M.; He, Z. X.; He, H. D.; Wang, L. F.
2016-04-01
The trapped electron modes (TEMs) are numerically investigated in toroidal magnetized hydrogen, deuterium and tritium plasmas, taking into account the effects of impurity ions such as carbon, oxygen, helium, tungsten and others with positive and negative density gradients with the rigorous integral eigenmode equation. The effects of impurity ions on TEMs are investigated in detail. It is shown that impurity ions have substantially-destabilizing (stabilizing) effects on TEMs in isotope plasmas for {{L}ez}\\equiv {{L}ne}/{{L}nz}>0 (<0 ), opposite to the case of ion temperature gradient (ITG) driven modes. Detailed analyses of the isotope mass dependence for TEM turbulences in hydrogenic isotope plasmas with and without impurities are performed. The relations between the maximum growth rate of the TEMs with respect to the poloidal wave number and the ion mass number are given in the presence of the impurity ions. The results demonstrate that the maximum growth rates scale as {γ\\max}\\propto Mi-0.5 in pure hydrogenic plasmas. The scale depends on the sign of its density gradient and charge number when there is a second species of (impurity) ions. When impurity ions have density profiles peaking inwardly (i.e. {{L}ez}\\equiv {{L}ne}/{{L}nz}>0 ), the scaling also depends on ITG parameter {ηi} . The maximum growth rates scale as {γ\\max}\\propto M\\text{eff}-0.5 for the case without ITG ({ηi}=0 ) or the ITG parameter is positive ({ηi}>0 ) but the impurity ion charge number is low (Z≤slant 5.0 ). However, when {ηi}>0 and the impurity ion charge number is moderate (Z=6.0-8.0 ), the scaling law is found as {γ\\max}\\propto M\\text{eff}-1.0 . Here, Z is impurity ion charge number, and the effective mass number, {{M}\\text{eff}}=≤ft(1-{{f}z}\\right){{M}i}+{{f}z}{{M}z} , with {{M}i} and {{M}Z} being the mass numbers of the hydrogenic and impurity ions, respectively, and {{f}z}=Z{{n}0z}/{{n}0e} being the charge concentration of impurity ions. In addition, with regard to the case of {{L}ez}<0 , the maximum growth rate scaling is {γ\\max}\\propto Mi-0.5 . The possible relations of the results with experimental observations are discussed.
Kovács, L; Kézér, F L; Kulcsár-Huszenicza, M; Ruff, F; Szenci, O; Jurkovich, V
2016-09-01
Behavior, hypothalamic-pituitary-adrenal axis, and cardiac autonomic nervous system (ANS) activity were evaluated in response to transrectal examination in nonlactating Holstein-Friesian cows with different behavioral reactivity. According to behavioral reactions shown to the procedure of fixing the heart rate (HR) monitors, the 20 cows with the highest and the 20 cows with the lowest behavioral reactivity were involved in the study (high responder, n=20; and low responder, n=20, respectively). Activity of the ANS was assessed by HR and HR variability parameters. Blood and saliva were collected at 5 min before (baseline) and 0, 5 10, 15, 20, 30, 40, 60, and 120 min after the examination to determine cortisol concentrations. The examination lasted for 5 min. Cardiac parameters included HR, the root mean square of successive differences between the consecutive interbeat intervals, the high frequency (HF) component of heart rate variability, and the ratio between the low frequency (LF) and HF parameter (LF/HF). Following the examination, peak plasma and saliva cortisol levels and the amplitude of the plasma and saliva cortisol response were higher in high responder cows than in low responders. Areas under the plasma and saliva cortisol response curves were greater in high responder cows. Plasma and salivary cortisol levels correlated significantly at baseline (r=0.91), right after examination (r=0.98), and at peak levels (r=0.96). Area under the HR response curve was higher in low responder cows; however, maximum HR and the amplitude of the HR response showed no differences between groups. Minimum values of both parameters calculated for the examination were higher in high responders. Following the examination, response parameters of root mean square of successive differences and HF did not differ between groups. The maximum and the amplitude of LF/HF response and area under the LF/HF response curve were lower in low responder cows, suggesting a lower sympathetic activation of the ANS. Although changes in behaviors indicated that the procedure was painful for the animals, no differences were observed either in vocalization or in attendant behavior between groups during the examination. Our results demonstrate that behaviorally more reactive animals exhibit increased plasma and salivary cortisol concentrations and higher cardiac autonomic responsiveness to transrectal examination than less reactive cows. Salivary cortisol may substitute for plasma cortisol when assessing response of cattle to stress. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Sharpening of the 6.8 nm peak in an Nd:YAG laser produced Gd plasma by using a pre-formed plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tian, Yong; Song, Xiaolin; Xie, Zhuo
For effective use of a laser-produced-plasma (LPP) light source, an LPP is desired to emit a narrow spectral peak because the reflection spectrum of multilayer mirrors for guiding emission from the source is very narrow. While a Gd plasma has been studied extensively as an extreme ultraviolet (EUV) light source at around 6.8 nm, where La/B{sub 4}C multilayer is reported to have a high reflectivity with a bandwidth of about 0.6 %, all previous works using an Nd:YAG laser reported very broad spectra. This paper reports the first narrowing of the 6.8 nm peak in the case of using anmore » Nd:YAG laser to generate a Gd plasma by using a pre-pulse. The best peak narrowing is observed when a pre-formed plasma is heated by a 1064 nm main laser pulse with a duration of 10 ns at the irradiation density of 4x 10{sup 11} W/cm{sup 2} at a delay time of 50 ns after the pre-pulse irradiation. The observed spectral width of about 0.3 nm is about one fifth of the value for no pre-formed plasma. The peak wavelength of the 6.8 nm band shifted to a longer wavelength side and the peak was broadened both for lower and higher laser irradiation density. It is discussed that this robustness of the peak position of the 6.8 nm Gd peak against temperature change is suitable to achieve a narrow bandwidth from an LPP generated on solid. The observed spectra are compared with those previously reported in various conditions.« less
Theusinger, Oliver M; Goslings, David; Studt, Jan-Dirk; Brand-Staufer, Brigitte; Seifert, Burkhardt; Spahn, Donat R; Frey, Beat M
2017-03-01
Different types of fresh-frozen plasma (FFP) exist, and the concentrations of plasma proteins vary between individuals and blood groups. Furthermore, processing may also influence the content. Quarantine-stored plasma (qFFP) and plasma that was pathogen-reduced using blood-safety (Intercept) technology (piFFP) were analyzed regarding procoagulant and anticoagulant hemostasis proteins, including endogenous thrombin (thrombin-generation) potential (ETP). Thirty-five samples of each type of FFP were analyzed using only male Blood Group O donors. FFP units were stored frozen for comparable periods of time before plasma protein content was assessed. Once the units were thawed, all tests were completed within 4 hours. The results are presented as means ± standard deviations or as median (minimum; maximum) and were compared using independent-sample t tests (significance, p < 0.01). Significantly higher concentrations of adintegrin-like and metalloprotease with thrombospondin type-13 motifs (ADAMTS13), fibrinogen, Factor (F)V, FVIII, FXIII, protein S, protein S activity, antithrombin, microvesicle (<900 nm), and α2 antiplasmin were observed in qFFP. The variability of factors was significantly lower in piFFP. Tissue factor (TF) at 1 picomolar (pM) exhibited significantly longer lag time, a lower peak, lower ETP, and a lower velocity index in qFFP compared with piFFP. In TF at 5 pM, significant differences in lag time (longer in qFFP), velocity index (lower in qFFP), and peak (lower in qFFP) were observed. Rotational thromboelastometry revealed a significantly longer (p = 0.002) clot-formation time with intrinsic thromboelastometry for piFFP and a significantly shorter clotting time (p = 0.004) with thromboelastometry fibrinogen testing for piFFP. Pathogen reduction reduces procoagulant and anticoagulant coagulation factors as well as variability. A thrombin-generation assay showed no reduced ETP and no supraphysiological thrombin generation. None of the FFP preparations is likely to be effective for treating fibrinogen deficiency. © 2016 AABB.
Characterization of an electrothermal plasma source for fusion transient simulations
NASA Astrophysics Data System (ADS)
Gebhart, T. E.; Baylor, L. R.; Rapp, J.; Winfrey, A. L.
2018-01-01
The realization of fusion energy requires materials that can withstand high heat and particle fluxes at the plasma material interface. In this work, an electrothermal (ET) plasma source has been designed as a transient heat flux source for a linear plasma material interaction device. An ET plasma source operates in the ablative arc regime driven by a DC capacitive discharge. The current channel width is defined by the 4 mm bore of a boron nitride liner. At large plasma currents, the arc impacts the liner wall, leading to high particle and heat fluxes to the liner material, which subsequently ablates and ionizes. This results in a high density plasma with a large unidirectional bulk flow out of the source exit. The pulse length for the ET source has been optimized using a pulse forming network to have durations of 1 and 2 ms. The peak currents and maximum source energies seen in this system are 1.9 kA and 1.2 kJ for the 2 ms pulse and 3.2 kA and 2.1 kJ for the 1 ms pulse, respectively. This work is a proof of the principal project to show that an ET source produces electron densities and heat fluxes comparable to those anticipated in transient events in large future magnetic confinement fusion devices. Heat flux, plasma temperature, and plasma density were determined for each shot using infrared imaging and optical spectroscopy techniques. This paper will discuss the assumptions, methods, and results of the experiments.
Pickup Ion Velocity Distributions at Titan: Effects of Spatial Gradients
NASA Technical Reports Server (NTRS)
Hartle, R. E.; Sittler, E. C.
2004-01-01
The principle source of pickup ions at Titan is its neutral exosphere, extending well above the ionopause into the magnetosphere of Saturn or the solar wind, depending on the moon's orbital position. Thermal and nonthermal processes in the thermosphere generate the distribution of neutral atoms and molecules in the exosphere. The combination of these processes and the range of mass numbers, 1 to over 28, contribute to an exospheric source structure that produces pickup ions with gyroradii that are much larger or smaller than the corresponding scale heights of their neutral sources. The resulting phase space distributions are dependent on the spatial structure of the exosphere as well as that of the magnetic field and background plasma. When the pickup ion gyroradius is less than the source gas scale height, the pickup ion velocity distribution is characterized by a sharp cutoff near the maximum speed, which is twice that of the ambient plasma times the sine of the angle between the magnetic field and the flow velocity. This was the case for pickup H(sup +) ions identified during the Voyager 1 flyby. In contrast, as the gyroradius becomes much larger than the scale height, the peak of the velocity distribution in the source region recedes from the maximum speed. Iri addition, the amplitude of the distribution near the maximum speed decreases. These more beam like distributions of heavy ions were not observed from Voyager 1 , but should be observable by more sensitive instruments on future spacecraft, including Cassini. The finite gyroradius effects in the pickup ion velocity distributions are studied by including in the analysis the possible range of spatial structures in the neutral exosphere and background plasma.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barada, Kshitish K.; Chattopadhyay, P. K.; Ghosh, J.
2013-01-15
Asymmetry in density peaks on either side of an m = +1 half helical antenna is observed both in terms of peak position and its magnitude with respect to magnetic field variation in a linear helicon plasma device [Barada et al., Rev. Sci. Instrum. 83, 063501 (2012)]. The plasma is produced by powering the m = +1 half helical antenna with a 2.5 kW, 13.56 MHz radio frequency source. During low magnetic field (B < 100 G) operation, plasma density peaks are observed at critical magnetic fields on either side of the antenna. However, the density peaks occurred at differentmore » critical magnetic fields on both sides of antenna. Depending upon the direction of the magnetic field, in the m = +1 propagation side, the main density peak has been observed around 30 G of magnetic field. On this side, the density peak around 5 G corresponding to electron cyclotron resonance (ECR) is not very pronounced, whereas in the m = -1 propagation side, very pronounced ECR peak has been observed around 5 G. Another prominent density peak around 12 G has also been observed in m = -1 side. However, no peak has been observed around 30 G on this m = -1 side. This asymmetry in the results on both sides is explained on the basis of polarization reversal of left hand polarized waves to right hand polarized waves and vice versa in a bounded plasma system. The density peaking phenomena are likely to be caused by obliquely propagating helicon waves at the resonance cone boundary.« less
Transition from the Unipolar Region to the Sector Zone: Voyager 2, 2013 and 2014
NASA Astrophysics Data System (ADS)
Burlaga, L. F.; Ness, N. F.; Richardson, J. D.
2017-05-01
We discuss magnetic field and plasma observations of the heliosheath made by Voyager 2 (V2) during 2013 and 2014 near solar maximum. A transition from a unipolar region to a sector zone was observed in the azimuthal angle λ between ˜2012.45 and 2013.82. The distribution of λ was strongly singly peaked at 270^\\circ in the unipolar region and double peaked in the sector zone. The δ-distribution was strongly peaked in the unipolar region and very broad in the sector zone. The distribution of daily averages of the magnetic field strength B was Gaussian in the unipolar region and lognormal in the sector zone. The correlation function of B was exponential with an e-folding time of ˜5 days in both regions. The distribution of hourly increments of B was a Tsallis distribution with nonextensivity parameter q = 1.7 ± 0.04 in the unipolar region and q = 1.44 ± 0.12 in the sector zone. The CR-B relationship qualitatively describes the 2013 observations, but not the 2014 observations. A 40 km s-1 increase in the bulk speed associated with an increase in B near 2013.5 might have been produced by the merging of streams. A “D sheet” (a broad depression in B containing a current sheet moved past V2 from days 320 to 345, 2013. The R- and N-components of the plasma velocity changed across the current sheet.
NASA Technical Reports Server (NTRS)
Clark, George W.; Woo, Jonathan W.; Nagase, Fumiaki; Makishima, Kazuo; Sakao, Taro
1990-01-01
A cyclotron absorption line near 20 keV has been found in the spectrum of the massive eclipsing binary X-ray pulsar 4U 1538 - 52 in observations with the Ginga observatory. The line is detected throughout the 529 s pulse cycle with a variable equivalent width that has its maximum value during the smaller peak of the two-peak pulse profile. It is found that the profile of the pulse and the phase-dependence of the cyclotron line can be explained qualitatively by a pulsar model based on recent theoretical results on the properties of pencil beams emitted by accretion-heated slabs of magnetized plasma at the magnetic poles of a neutron star. The indicated field at the surface of the neutron star is 1.7 (1 + z) x 10 to the 12th G, where z is the gravitational redshift.
Koga, T; Moro, K; Nakamori, K; Yamakoshi, J; Hosoyama, H; Kataoka, S; Ariga, T
1999-05-01
The effect of a single oral administration of proanthocyanidins, oligomeric and polymeric polyhydroxyflavan-3-ol units, on the antioxidative potential of blood plasma was studied in rats. Proanthocyanidin-rich extract from grape seeds was administered by intragastric intubation to fasted rats at 250 mg/kg of body weight. The plasma obtained from water- or proanthocyanidin-administered rats was oxidized by incubation with copper sulfate or 2, 2'-azobis(2-amidinopropane) dihydrochloride (AAPH) at 37 degrees C, and the formation of cholesteryl ester hydroperoxides (CE-OOH) was followed. The plasma obtained from proanthocyanidin-administered rats was significantly more resistant against both copper ion-induced and AAPH-induced formation of CE-OOH than that from control rats. The lag phase in the copper ion-induced oxidation of rat plasma was remarkably increased at 15 min after administration of proanthocyanidins and reached a maximum level at 30 min. When the plasma from proanthocyanidin-administered rat was hydrolyzed by sulfatase and beta-glucuronidase following analysis by high-performance liquid chromatography with electrochemical detection, metabolites of proanthocyanidins occurred in rat plasma at 15 min after administration, three peaks of which were identified as gallic acid, (+)-catechin, and (-)-epicatechin. These results suggest that the intake of proanthocyanidins, the major polyphenols in red wine, increases the resistance of blood plasma against oxidative stress and may contribute to physiological functions of plant food including wine through their in vivo antioxidative ability.
High-energy-density plasma jet generated by laser-cone interaction
NASA Astrophysics Data System (ADS)
Ke, Y. Z.; Yang, X. H.; Ma, Y. Y.; Xu, B. B.; Ge, Z. Y.; Gan, L. F.; Meng, L.; Wang, S. W.; Kawata, S.
2018-04-01
The generation of high-energy-density (HED) plasma jet from a laser ablating thin cone target is studied theoretically and by numerical simulations. Theoretical analysis and 1D simulations show that a maximum kinetic energy conversion efficiency (CE) of 26% can be achieved when nearly 80% of the foil is ablated by laser. A HED plasma jet is generated when an intense laser (˜1015 W/cm2) irradiates the cone target, inducing a great enhancement of energy density compared to that of the planar target, which is attributed to the cumulative effect of the cone shape and the new generation mechanism of jet, i.e., laser directly accelerating the cone wall onto the axis. The characteristic of jet is influenced by the cone geometry, i.e., thickness and cone angle. It is found that a cone with a half opening angle around 70 ° and the optimized thickness (˜5 μm) can induce a jet with a high CE and long duration, whose peak energy density can reach 3.5 × 1015 erg/cm3. The results can be beneficial for laser-driven novel neutron sources and other fusion related experiments, where HED plasma jet can be applied.
Two hump-shaped angular distributions of neutrons and soft X-rays in a small plasma focus device.
Habibi, Morteza
2018-03-01
Angular distributions of soft X-rays (SXRs) and neutrons emitted by a small plasma focus device (PFD) were investigated simultaneously using TLD-100 dosimeters and Geiger-Muller activation counters, respectively. The distributions represented two humps with a small dip at the angular position 0° and reduced from the angles of ± 15° and ± 30° for the neutrons and SXRs, respectively. The maximum yield of 2.98 × 10 8 neutrons per shot of the device was obtained at 13.5kV and 6.5mbar. A time of flight (TOF) of 75.2ns between the hard X-ray and the neutron peaks corresponds to neutrons with energy of 2.67MeV. A similar behavior was observed between the angular distributions of neutron and soft X-ray emissions. Copyright © 2018 Elsevier Ltd. All rights reserved.
Momentum balance in four solar flares
NASA Technical Reports Server (NTRS)
Canfield, Richard C.; Metcalf, Thomas R.; Zarro, Dominic M.; Lemen, James R.
1990-01-01
Solar Maximum Mission soft X-ray spectra and National Solar Observatory (Sacramento Peak) H-alpha spectra were combined in a study of high-speed flows during the impulsive phase of four solar flares. In all events, a blue asymmetry (indicative of upflows) was observed in the coronal Ca XIX line during the soft X-ray rise phase. In all events a red asymmetry (indicative of downflows) was observed simultaneously in chromospheric H-alpha. These oppositely directed flows were concurrent with impulsive hard X-ray emission. Combining the velocity data with estimates of the density based on emission measurements and volume estimates, it is shown that for the impulsive phase as a whole the total momentum of upflowing soft X-ray plasma equaled that of the downflowing H-alpha plasma, to within an order of magnitude, in all four events. Only the chromospheric evaporation model predicts equal total momentum in the upflowing soft X-ray-emitting and downflowing H-alphba-emitting materials.
Excitation of lower hybrid waves by a spiraling ion beam in a magnetized dusty plasma cylinder
NASA Astrophysics Data System (ADS)
Sharma, Suresh C.; Walia, Ritu
2008-09-01
A spiraling ion beam propagating through a magnetized dusty plasma cylinder drives electrostatic lower hybrid waves to instability via cyclotron interaction. Numerical calculations of the growth rate and unstable mode frequencies have been carried out for the Princeton Q-1 device using the experimental dusty plasma parameters [e.g., Barkan et al., Planet. Space Sci. 43, 905 (1995)]. It is found that as the density ratio δ(=nio/neo, where ni0 is the ion plasma density and ne0 is the electron density) of negatively charged dust grains to electrons increases, the unstable mode frequency of the lower hybrid waves increases. In addition, the growth rate of the instability also increases with the density ratio δ. In other words, the presence of negatively charged dust grains can further destabilize the lower hybrid wave instability. The growth rate has the largest value for the modes where Jl(pnro) is maximum [here pn=xn/r0, where pn is the perpendicular wave number in cm-1, r0 is the plasma radius, and xn are the zeros of the Bessel function J1(x )] i.e., whose eigenfunctions peak at the location of the beam. The growth rate scales as one third power of the beam current.
NASA Astrophysics Data System (ADS)
Takase, Kazuki; Takahashi, Kazunori; Takao, Yoshinori
2018-02-01
The effects of neutral distribution and an external magnetic field on plasma distribution and thruster performance are numerically investigated using a particle-in-cell simulation with Monte Carlo collisions (PIC-MCC) and the direct simulation Monte Carlo (DSMC) method. The modeled thruster consists of a quartz tube 1 cm in diameter and 3 cm in length, where a double-turn rf loop antenna is wound at the center of the tube and a solenoid is placed between the loop antenna and the downstream tube exit. A xenon propellant is introduced from both the upstream and downstream sides of the thruster, and the flow rates are varied while maintaining the total gas flow rate of 30 μg/s. The PIC-MCC calculations have been conducted using the neutral distribution obtained from the DSMC calculations, which were applied with different strengths of the magnetic field. The numerical results show that both the downstream gas injection and the external magnetic field with a maximum strength near the thruster exit lead to a shift of the plasma density peak from the upstream to the downstream side. Consequently, a larger total thrust is obtained when increasing the downstream gas injection and the magnetic field strength, which qualitatively agrees with a previous experiment using a helicon plasma source.
Lis, Karolina Anna; Binder, Sylvia; Li, Yangfang; Kehrenberg, Corinna; Zimmermann, Julia Louise; Ahlfeld, Birte
2018-01-01
The application of cold atmospheric pressure plasma (CAP) for decontamination of sliced ready-to-eat (RTE) meat products (in this case, rolled fillets of ham), inoculated with Salmonella (S.) Typhimurium and Listeria (L.) monocytogenes was investigated. Cold atmospheric plasma (CAP) is an ionised gas that includes highly reactive species and ozone, interacting with cell membranes and DNA of bacteria. The mode of action of CAPs includes penetration and disruption of the outer cell membrane or intracellular destruction of DNA located in the cytoplasm. Inoculated ham was treated for 10 and 20 min with CAP generated by a surface-micro-discharge-plasma source using cost-effective ambient air as working gas with different humidity levels of 45–50 and 90%. The chosen plasma modes had a peak-to-peak voltage of 6.4 or 10 kV and a frequency of 2 and 10 kHz. Under the tested conditions, the direct effectiveness of CAP on microbial inactivation was limited. Although all treated samples showed significant reductions in the microbial load subsequent to plasma treatment, the maximum inactivation of S. Typhimurium was 1.14 lg steps after 20 min of CAP-treatment (p<0.05), and L. monocytogenes was reduced by 1.02 lg steps (p<0.05) using high peak-to-peak voltage of 10 kV and a frequency of 2 kHz regardless of moisture content. However, effective inactivation was achieved by a combination of CAP-treatment and cold storage at 8°C ± 0.5°C for 7 and 14 days after packaging under sealed high nitrogen gas flush (70% N2, 30% CO2). Synergistic effects of CAP and cold storage for 14 days led to a clearer decrease in the microbial load of 1.84 lg steps for S. Typhimurium (p<0.05) and 2.55 lg steps for L. monocytogenes (p<0.05). In the case of L. monocytogenes, subsequent to CAP-treatment (10 kV, 2 kHz) and cold storage, microbial counts were predominantly below the detection limit. Measurement showed that after CAP-treatment, surface temperature of ham did not exceed the room temperature of 22°C ± 2°C. With the application of humidity levels of 45–50%, the colour distance ΔE increased in CAP treated samples due to a decrease in L* values. In conclusion, effectiveness of CAP-treatment was limited. However, the combination of CAP-treatment and cold storage of samples under modified-atmospheric-conditions up to 14 days could significantly reduce microorganisms on RTE ham. Further investigations are required to improve effectiveness of CAP-treatment. PMID:29795627
Lis, Karolina Anna; Boulaaba, Annika; Binder, Sylvia; Li, Yangfang; Kehrenberg, Corinna; Zimmermann, Julia Louise; Klein, Günter; Ahlfeld, Birte
2018-01-01
The application of cold atmospheric pressure plasma (CAP) for decontamination of sliced ready-to-eat (RTE) meat products (in this case, rolled fillets of ham), inoculated with Salmonella (S.) Typhimurium and Listeria (L.) monocytogenes was investigated. Cold atmospheric plasma (CAP) is an ionised gas that includes highly reactive species and ozone, interacting with cell membranes and DNA of bacteria. The mode of action of CAPs includes penetration and disruption of the outer cell membrane or intracellular destruction of DNA located in the cytoplasm. Inoculated ham was treated for 10 and 20 min with CAP generated by a surface-micro-discharge-plasma source using cost-effective ambient air as working gas with different humidity levels of 45-50 and 90%. The chosen plasma modes had a peak-to-peak voltage of 6.4 or 10 kV and a frequency of 2 and 10 kHz. Under the tested conditions, the direct effectiveness of CAP on microbial inactivation was limited. Although all treated samples showed significant reductions in the microbial load subsequent to plasma treatment, the maximum inactivation of S. Typhimurium was 1.14 lg steps after 20 min of CAP-treatment (p<0.05), and L. monocytogenes was reduced by 1.02 lg steps (p<0.05) using high peak-to-peak voltage of 10 kV and a frequency of 2 kHz regardless of moisture content. However, effective inactivation was achieved by a combination of CAP-treatment and cold storage at 8°C ± 0.5°C for 7 and 14 days after packaging under sealed high nitrogen gas flush (70% N2, 30% CO2). Synergistic effects of CAP and cold storage for 14 days led to a clearer decrease in the microbial load of 1.84 lg steps for S. Typhimurium (p<0.05) and 2.55 lg steps for L. monocytogenes (p<0.05). In the case of L. monocytogenes, subsequent to CAP-treatment (10 kV, 2 kHz) and cold storage, microbial counts were predominantly below the detection limit. Measurement showed that after CAP-treatment, surface temperature of ham did not exceed the room temperature of 22°C ± 2°C. With the application of humidity levels of 45-50%, the colour distance ΔE increased in CAP treated samples due to a decrease in L* values. In conclusion, effectiveness of CAP-treatment was limited. However, the combination of CAP-treatment and cold storage of samples under modified-atmospheric-conditions up to 14 days could significantly reduce microorganisms on RTE ham. Further investigations are required to improve effectiveness of CAP-treatment.
Portnow, Jana; Badie, Behnam; Chen, Mike; Liu, An; Blanchard, Suzette; Synold, Timothy W.
2010-01-01
Purpose Intracerebral microdialysis (ICMD) is an accepted methodology for monitoring changes in neurochemistry from acute brain injury. The goal of this pilot study was to determine the feasibility of using ICMD to examine the neuropharmacokinetics (nPK) of temozolomide (TMZ) in brain interstitium (BI) following oral administration. Experimental Design Patients with primary or metastatic brain tumors had a microdialysis catheter placed in peritumoral brain tissue at the time of surgical debulking. CT scan confirmed the catheter location. Patients received a single oral dose of TMZ (150 mg/m2) on the first post-operative day, serial plasma and ICMD samples were collected over 24 hrs, and TMZ concentrations were determined by tandem mass spectrometry. Results Nine patients were enrolled. Dialysate and plasma samples were successfully collected from 7 of the 9 patients. The mean TMZ area-under-the-concentration-time-curve (AUC) in plasma and BI were 17.1 and 2.7 μg/ml × hr, with an average BI/plasma AUC ratio of 17.8%. The mean peak TMZ concentration in brain was 0.6 ± 0.3 μg/ml, and the mean time to reach peak level in brain was 2.0 ± 0.8 hrs. Conclusions The use of ICMD to measure the nPK of systemically administered chemotherapy is safe and feasible. Concentrations of TMZ in BI obtained by ICMD are consistent with published data obtained in a pre-clinical ICMD model, as well as from clinical studies of cerebrospinal fluid. However, the delayed time required to achieve maximum TMZ concentrations in brain suggests that current chemoradiation regimens may be improved by administering TMZ 2-3 hours before radiation. PMID:19861433
Portnow, Jana; Badie, Behnam; Chen, Mike; Liu, An; Blanchard, Suzette; Synold, Timothy W
2009-11-15
Intracerebral microdialysis (ICMD) is an accepted method for monitoring changes in neurochemistry from acute brain injury. The goal of this pilot study was to determine the feasibility of using ICMD to examine the neuropharmacokinetics of temozolomide in brain interstitium following oral administration. Patients with primary or metastatic brain tumors had a microdialysis catheter placed in peritumoral brain tissue at the time of surgical debulking. Computerized tomography scan confirmed the catheter location. Patients received a single oral dose of temozolomide (150 mg/m2) on the first postoperative day, serial plasma and ICMD samples were collected over 24 hours, and temozolomide concentrations were determined by tandem mass spectrometry. Nine patients were enrolled. Dialysate and plasma samples were successfully collected from seven of the nine patients. The mean temozolomide areas under the concentration-time curve (AUC) in plasma and brain interstitium were 17.1 and 2.7 microg/mL x hour, with an average brain interstitium/plasma AUC ratio of 17.8%. The mean peak temozolomide concentration in the brain was 0.6 +/- 0.3 microg/mL, and the mean time to reach peak level in brain was 2.0 +/- 0.8 hours. The use of ICMD to measure the neuropharmacokinetics of systemically administered chemotherapy is safe and feasible. Concentrations of temozolomide in brain interstitium obtained by ICMD are consistent with published data obtained in a preclinical ICMD model, as well as from clinical studies of cerebrospinal fluid. However, the delayed time required to achieve maximum temozolomide concentrations in brain suggests that current chemoradiation regimens may be improved by administering temozolomide 2 to 3 hours before radiation.
NASA Astrophysics Data System (ADS)
Li, M.; Yu, T.; Chunliang, X.; Zuo, X.; Liu, Z.
2017-12-01
A new method for estimating the equatorial plasma bubbles (EPBs) motions from airglow emission all-sky images is presented in this paper. This method, which is called 'cloud-derived wind technology' and widely used in satellite observation of wind, could reasonable derive zonal and meridional velocity vectors of EPBs drifts by tracking a series of successive airglow 630.0 nm emission images. Airglow emission images data are available from an all sky airglow camera in Hainan Fuke (19.5°N, 109.2°E) supported by China Meridional Project, which can receive the 630.0nm emission from the ionosphere F region at low-latitudes to observe plasma bubbles. A series of pretreatment technology, e.g. image enhancement, orientation correction, image projection are utilized to preprocess the raw observation. Then the regions of plasma bubble extracted from the images are divided into several small tracing windows and each tracing window can find a target window in the searching area in following image, which is considered as the position tracing window moved to. According to this, velocities in each window are calculated by using the technology of cloud-derived wind. When applying the cloud-derived wind technology, the maximum correlation coefficient (MCC) and the histogram of gradient (HOG) methods to find the target window, which mean to find the maximum correlation and the minimum euclidean distance between two gradient histograms in respectively, are investigated and compared in detail. The maximum correlation method is fianlly adopted in this study to analyze the velocity of plasma bubbles because of its better performance than HOG. All-sky images from Hainan Fuke, between August 2014 and October 2014, are analyzed to investigate the plasma bubble drift velocities using MCC method. The data at different local time at 9 nights are studied and find that zonal drift velocity in different latitude at different local time ranges from 50 m/s to 180 m/s and there is a peak value at about 20°N. For comparison and validation, EPBs motions obtained from three traditional methods are also investigated and compared with MC method. The advantages and disadvantages of using cloud-derived wind technology to calculate EPB drift velocity are discussed.
Current responsive devices for synchronous generators
Karlicek, Robert F.
1983-01-01
A device for detecting current imbalance between phases of a polyphase alternating current generator. A detector responds to the maximum peak current in the generator, and detecting means generates an output for each phase proportional to the peak current of each phase. Comparing means generates an output when the maximum peak current exceeds the phase peak current.
ZT Optimization: An Application Focus
Tuley, Richard; Simpson, Kevin
2017-01-01
Significant research has been performed on the challenge of improving thermoelectric materials, with maximum peak figure of merit, ZT, the most common target. We use an approximate thermoelectric material model, matched to real materials, to demonstrate that when an application is known, average ZT is a significantly better optimization target. We quantify this difference with some examples, with one scenario showing that changing the doping to increase peak ZT by 19% can lead to a performance drop of 16%. The importance of average ZT means that the temperature at which the ZT peak occurs should be given similar weight to the value of the peak. An ideal material for an application operates across the maximum peak ZT, otherwise maximum performance occurs when the peak value is reduced in order to improve the peak position. PMID:28772668
Broad ion energy distributions in helicon wave-coupled helium plasma
NASA Astrophysics Data System (ADS)
Woller, K. B.; Whyte, D. G.; Wright, G. M.
2017-05-01
Helium ion energy distributions were measured in helicon wave-coupled plasmas of the dynamics of ion implantation and sputtering of surface experiment using a retarding field energy analyzer. The shape of the energy distribution is a double-peak, characteristic of radiofrequency plasma potential modulation. The broad distribution is located within a radius of 0.8 cm, while the quartz tube of the plasma source has an inner radius of 2.2 cm. The ion energy distribution rapidly changes from a double-peak to a single peak in the radius range of 0.7-0.9 cm. The average ion energy is approximately uniform across the plasma column including the double-peak and single peak regions. The widths of the broad distribution, ΔE , in the wave-coupled mode are large compared to the time-averaged ion energy, ⟨E ⟩. On the axis (r = 0), ΔE / ⟨E ⟩ ≲ 3.4, and at a radius near the edge of the plasma column (r = 2.2 cm), ΔE / ⟨E ⟩ ˜ 1.2. The discharge parameter space is scanned to investigate the effects of the magnetic field, input power, and chamber fill pressure on the wave-coupled mode that exhibits the sharp radial variation in the ion energy distribution.
Analysis of Rotation and Transport Data in C-Mod ITB Plasmas
NASA Astrophysics Data System (ADS)
Fiore, C. L.; Rice, J. E.; Reinke, M. L.; Podpaly, Y.; Bespamyatnov, I. O.; Rowan, W. L.
2009-11-01
Internal transport barriers (ITBs) spontaneously form near the half radius of Alcator C-Mod plasmas when the EDA H-mode is sustained for several energy confinement times in either off-axis ICRF heated discharges or in purely ohmic heated plasmas. These plasmas exhibit strongly peaked density and pressure profiles, static or peaking temperature profiles, peaking impurity density profiles, and thermal transport coefficients that approach neoclassical values in the core. It has long been observed that the intrinsic central plasma rotation that is strongly co-current following the H-mode transition slows and often reverses as the density peaks as the ITB forms. Recent spatial measurements demonstrate that the rotation profile develops a well in the core region that decreases continuously as central density rises while the value outside of the core remains strongly co-current. This results in the formation of a steep potential gradient/strong electric field at the location of the foot of the ITB density profile. The resulting E X B shearing rate is also quite significant at the foot. These analyses and the implications for plasma transport and stability will be presented.
NASA Astrophysics Data System (ADS)
Ionin, A. A.; Mokrousova, D. V.; Piterimov, D. A.; Seleznev, L. V.; Sinitsyn, D. V.; Sunchugasheva, E. S.
2018-04-01
The critical power for self-focusing in air for ultrashort ultraviolet laser pulses, stretched due to dispersion from 90 to 730 fs, was experimentally measured. It was shown that the pulse duration enhancement due to its propagation in condensed media leads to an almost linear decrease in the critical power for self-focusing. It was also observed that when the pulse peak power exceeds the critical one, the maximum of linear plasma distribution along the ultraviolet laser filament does not shift in the direction opposite to the laser pulse propagation, as observed for infrared laser filaments, but remains at the geometrical focus.
Characterization of an electrothermal plasma source for fusion transient simulations
Gebhart, T. E.; Baylor, Larry R.; Rapp, Juergen; ...
2018-01-21
The realization of fusion energy requires materials that can withstand high heat and particle fluxes at the plasma material interface. Here in this work, an electrothermal (ET) plasma source has been designed as a transient heat flux source for a linear plasma material interaction device. An ET plasma source operates in the ablative arc regime driven by a DC capacitive discharge. The current channel width is defined by the 4 mm bore of a boron nitride liner. At large plasma currents, the arc impacts the liner wall, leading to high particle and heat fluxes to the liner material, which subsequentlymore » ablates and ionizes. This results in a high density plasma with a large unidirectional bulk flow out of the source exit. The pulse length for the ET source has been optimized using a pulse forming network to have durations of 1 and 2 ms. The peak currents and maximum source energies seen in this system are 1.9 kA and 1.2 kJ for the 2 ms pulse and 3.2 kA and 2.1 kJ for the 1 ms pulse, respectively. This work is a proof of the principal project to show that an ET source produces electron densities and heat fluxes comparable to those anticipated in transient events in large future magnetic confinement fusion devices. Heat flux, plasma temperature, and plasma density were determined for each shot using infrared imaging and optical spectroscopy techniques. This paper will discuss the assumptions, methods, and results of the experiments.« less
Characterization of an electrothermal plasma source for fusion transient simulations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gebhart, T. E.; Baylor, Larry R.; Rapp, Juergen
The realization of fusion energy requires materials that can withstand high heat and particle fluxes at the plasma material interface. Here in this work, an electrothermal (ET) plasma source has been designed as a transient heat flux source for a linear plasma material interaction device. An ET plasma source operates in the ablative arc regime driven by a DC capacitive discharge. The current channel width is defined by the 4 mm bore of a boron nitride liner. At large plasma currents, the arc impacts the liner wall, leading to high particle and heat fluxes to the liner material, which subsequentlymore » ablates and ionizes. This results in a high density plasma with a large unidirectional bulk flow out of the source exit. The pulse length for the ET source has been optimized using a pulse forming network to have durations of 1 and 2 ms. The peak currents and maximum source energies seen in this system are 1.9 kA and 1.2 kJ for the 2 ms pulse and 3.2 kA and 2.1 kJ for the 1 ms pulse, respectively. This work is a proof of the principal project to show that an ET source produces electron densities and heat fluxes comparable to those anticipated in transient events in large future magnetic confinement fusion devices. Heat flux, plasma temperature, and plasma density were determined for each shot using infrared imaging and optical spectroscopy techniques. This paper will discuss the assumptions, methods, and results of the experiments.« less
Current responsive devices for synchronous generators
Karlicek, R.F.
1983-09-27
A device for detecting current imbalance between phases of a polyphase alternating current generator. A detector responds to the maximum peak current in the generator, and detecting means generates an output for each phase proportional to the peak current of each phase. Comparing means generates an output when the maximum peak current exceeds the phase peak current. 11 figs.
NASA Technical Reports Server (NTRS)
Becker, Joseph F.; Valentin, Jose
1996-01-01
The maximum entropy technique was successfully applied to the deconvolution of overlapped chromatographic peaks. An algorithm was written in which the chromatogram was represented as a vector of sample concentrations multiplied by a peak shape matrix. Simulation results demonstrated that there is a trade off between the detector noise and peak resolution in the sense that an increase of the noise level reduced the peak separation that could be recovered by the maximum entropy method. Real data originated from a sample storage column was also deconvoluted using maximum entropy. Deconvolution is useful in this type of system because the conservation of time dependent profiles depends on the band spreading processes in the chromatographic column, which might smooth out the finer details in the concentration profile. The method was also applied to the deconvolution of previously interpretted Pioneer Venus chromatograms. It was found in this case that the correct choice of peak shape function was critical to the sensitivity of maximum entropy in the reconstruction of these chromatograms.
Peake, Jonathan M; Tan, Sok Joo; Markworth, James F; Broadbent, James A; Skinner, Tina L; Cameron-Smith, David
2014-10-01
This study investigated the effects of high-intensity interval training (HIIT) vs. work-matched moderate-intensity continuous exercise (MOD) on metabolism and counterregulatory stress hormones. In a randomized and counterbalanced order, 10 well-trained male cyclists and triathletes completed a HIIT session [81.6 ± 3.7% maximum oxygen consumption (V̇o2 max); 72.0 ± 3.2% peak power output; 792 ± 95 kJ] and a MOD session (66.7 ± 3.5% V̇o2 max; 48.5 ± 3.1% peak power output; 797 ± 95 kJ). Blood samples were collected before, immediately after, and 1 and 2 h postexercise. Carbohydrate oxidation was higher (P = 0.037; 20%), whereas fat oxidation was lower (P = 0.037; -47%) during HIIT vs. MOD. Immediately after exercise, plasma glucose (P = 0.024; 20%) and lactate (P < 0.01; 5.4×) were higher in HIIT vs. MOD, whereas total serum free fatty acid concentration was not significantly different (P = 0.33). Targeted gas chromatography-mass spectromtery metabolomics analysis identified and quantified 49 metabolites in plasma, among which 11 changed after both HIIT and MOD, 13 changed only after HIIT, and 5 changed only after MOD. Notable changes included substantial increases in tricarboxylic acid intermediates and monounsaturated fatty acids after HIIT and marked decreases in amino acids during recovery from both trials. Plasma adrenocorticotrophic hormone (P = 0.019), cortisol (P < 0.01), and growth hormone (P < 0.01) were all higher immediately after HIIT. Plasma norepinephrine (P = 0.11) and interleukin-6 (P = 0.20) immediately after exercise were not significantly different between trials. Plasma insulin decreased during recovery from both HIIT and MOD (P < 0.01). These data indicate distinct differences in specific metabolites and counterregulatory hormones following HIIT vs. MOD and highlight the value of targeted metabolomic analysis to provide more detailed insights into the metabolic demands of exercise. Copyright © 2014 the American Physiological Society.
Coiro, Vittorio; Volpi, Riccardo; Casti, Amos; Maffei, Maria Ludovica; Stella, Adriano; Volta, Elio; Chiodera, Paolo
2011-01-01
AIMS To establish the possible involvement of alprazolam (ALP) and/or opiates in the mechanism underlying the ACTH/cortisol response to physical exercise. METHODS Tests were carried out under basal conditions (exercise control test), exercise plus ALP (50 µg at time −90 min), naloxone (10 mg at time 0) or ALP plus naloxone. Plasma ACTH and serum cortisol concentrations were evaluated in blood samples taken before, during and after the bicycle ergometer tests. RESULTS ACTH and cortisol concentrations rose significantly after physical exercise. Maximum peak at time 15 min (P≤ 0.01 vs. baseline) for ACTH and at time 30 min (P≤ 0.01 vs. baseline) for cortisol. In the presence of naloxone, the ACTH and cortisol responses were significantly increased (maximum peak at time 20 min, P≤ 0.02 vs. control test for ACTH, and at time 30 min (P≤ 0.01 vs. baseline) for cortisol) whereas they were abolished by ALP. When ALP and naloxone were given together, the inhibitory effect of ALP was partial. CONCLUSIONS These data demonstrate an inhibitory effect of ALP in the regulation of the ACTH/cortisol response to physical exercise in man and suggest that GABAergic receptor activating benzodiazepines and opioids interact in the neuroendocrine secretion of ACTH/cortisol. PMID:21564163
First-principles equation of state and shock compression predictions of warm dense hydrocarbons
Zhang, Shuai; Driver, Kevin P.; Soubiran, Francois; ...
2017-07-10
We use path integral Monte Carlo and density functional molecular dynamics to construct a coherent set of equations of state (EOS) for a series of hydrocarbon materials with various C:H ratios (2:1, 1:1, 2:3, 1:2, and 1:4) over the range of 0.07–22.4gcm –3 and 6.7 × 10 3 – 1.29 × 10 8K. The shock Hugoniot curve derived for each material displays a single compression maximum corresponding to K-shell ionization. For C:H = 1:1, the compression maximum occurs at 4.7-fold of the initial density and we show radiation effects significantly increase the shock compression ratio above 2 Gbar, surpassing relativisticmore » effects. The single-peaked structure of the Hugoniot curves contrasts with previous work on higher-Z plasmas, which exhibit a two-peak structure corresponding to both K- and L-shell ionization. Analysis of the electronic density of states reveals that the change in Hugoniot structure is due to merging of the L-shell eigenstates in carbon, while they remain distinct for higher-Z elements. Lastly, we show that the isobaric-isothermal linear mixing rule for carbon and hydrogen EOS is a reasonable approximation with errors better than 1% for stellar-core conditions.« less
First-principles equation of state and shock compression predictions of warm dense hydrocarbons
NASA Astrophysics Data System (ADS)
Zhang, Shuai; Driver, Kevin P.; Soubiran, François; Militzer, Burkhard
2017-07-01
We use path integral Monte Carlo and density functional molecular dynamics to construct a coherent set of equations of state (EOS) for a series of hydrocarbon materials with various C:H ratios (2:1, 1:1, 2:3, 1:2, and 1:4) over the range of 0.07 -22.4 g cm-3 and 6.7 ×103-1.29 ×108K . The shock Hugoniot curve derived for each material displays a single compression maximum corresponding to K -shell ionization. For C:H = 1:1, the compression maximum occurs at 4.7-fold of the initial density and we show radiation effects significantly increase the shock compression ratio above 2 Gbar, surpassing relativistic effects. The single-peaked structure of the Hugoniot curves contrasts with previous work on higher-Z plasmas, which exhibit a two-peak structure corresponding to both K - and L -shell ionization. Analysis of the electronic density of states reveals that the change in Hugoniot structure is due to merging of the L -shell eigenstates in carbon, while they remain distinct for higher-Z elements. Finally, we show that the isobaric-isothermal linear mixing rule for carbon and hydrogen EOS is a reasonable approximation with errors better than 1% for stellar-core conditions.
NASA Astrophysics Data System (ADS)
Mukai, K.; Nagaoka, K.; Takahashi, H.; Yokoyama, M.; Murakami, S.; Nakano, H.; Ida, K.; Yoshinuma, M.; Seki, R.; Kamio, S.; Fujiwara, Y.; Oishi, T.; Goto, M.; Morita, S.; Morisaki, T.; Osakabe, M.; LHD Experiment Group1, the
2018-07-01
The behavior of carbon impurities in deuterium plasmas and its impact on thermal confinement were investigated in comparison with hydrogen plasmas in the Large Helical Device (LHD). Deuterium plasma experiments have been started in the LHD and high-ion-temperature plasmas with central ion temperature (T i) of 10 keV were successfully obtained. The thermal confinement improvement could be sustained for a longer time compared with hydrogen plasmas. An isotope effect was observed in the time evolution of the carbon density profiles. A transiently peaked profile was observed in the deuterium plasmas due to the smaller carbon convection velocity and diffusivity in the deuterium plasmas compared with the hydrogen plasmas. The peaked carbon density profile was strongly correlated to the ion thermal confinement improvement. The peaking of the carbon density profile will be one of the clues to clarify the unexplained mechanisms for the formations of ion internal transport barrier and impurity hole on LHD. These results could also lead to a better understanding of the isotope effect in the thermal confinement in torus plasma.
Rotation and transport in Alcator C-Mod ITB plasmas
NASA Astrophysics Data System (ADS)
Fiore, C. L.; Rice, J. E.; Podpaly, Y.; Bespamyatnov, I. O.; Rowan, W. L.; Hughes, J. W.; Reinke, M.
2010-06-01
Internal transport barriers (ITBs) are seen under a number of conditions in Alcator C-Mod plasmas. Most typically, radio frequency power in the ion cyclotron range of frequencies (ICRFs) is injected with the second harmonic of the resonant frequency for minority hydrogen ions positioned off-axis at r/a > 0.5 to initiate the ITBs. They can also arise spontaneously in ohmic H-mode plasmas. These ITBs typically persist tens of energy confinement times until the plasma terminates in radiative collapse or a disruption occurs. All C-Mod core barriers exhibit strongly peaked density and pressure profiles, static or peaking temperature profiles, peaking impurity density profiles and thermal transport coefficients that approach neoclassical values in the core. The strongly co-current intrinsic central plasma rotation that is observed following the H-mode transition has a profile that is peaked in the centre of the plasma and decreases towards the edge if the ICRF power deposition is in the plasma centre. When the ICRF resonance is placed off-axis, the rotation develops a well in the core region. The central rotation continues to decrease as long as the central density peaks when an ITB develops. This rotation profile is flat in the centre (0 < r/a < 0.4) but rises steeply in the region where the foot in the ITB density profile is observed (0.5 < r/a < 0.7). A correspondingly strong E × B shear is seen at the location of the ITB foot that is sufficiently large to stabilize ion temperature gradient instabilities that dominate transport in C-Mod high density plasmas.
Modelling of crater formation on anode surface by high-current vacuum arcs
NASA Astrophysics Data System (ADS)
Tian, Yunbo; Wang, Zhenxing; Jiang, Yanjun; Ma, Hui; Liu, Zhiyuan; Geng, Yingsan; Wang, Jianhua; Nordlund, Kai; Djurabekova, Flyura
2016-11-01
Anode melting and crater formation significantly affect interruption of high-current vacuum arcs. The primary objective of this paper is to theoretically investigate the mechanism of anode surface crater formation, caused by the combined effect of surface heating during the vacuum arc and pressure exerted on the molten surface by ions and electrons from the arc plasma. A model of fluid flow and heat transfer in the arc anode is developed and combined with a magnetohydrodynamics model of the vacuum arc plasma. Crater formation is observed in simulation for a peak arcing current higher than 15 kA on 40 mm diam. Cu electrodes spaced 10 mm apart. The flow of liquid metal starts after 4 or 5 ms of arcing, and the maximum velocities are 0.95 m/s and 1.39 m/s for 20 kA and 25 kA arcs, respectively. This flow redistributes thermal energy, and the maximum temperature of the anode surface does not remain in the center. Moreover, the condition for the liquid droplet formation on the anode surfaces is developed. The solidification process after current zero is also analyzed. The solidification time has been found to be more than 3 ms after 25 kA arcing. The long solidification time and sharp features on crater rims induce Taylor cone formation.
Konturek, J W
1994-12-01
Exogenous cholecystokinin (CCK) is known to effect gastric secretory and motor functions but its physiological role in the control of these functions in healthy subjects and duodenal ulcer (DU) patients is unknown. In this study involving four series of young healthy normal and DU subjects, the gastric secretory tests were performed under basal conditions and following stimulation by modified sham-feeding (MSF), i.v. infusion of caerulein, gastrin releasing peptide (GRP) or pentagastrin (p-gastrin) (series A), after 500 ml of standard meal without or with addition of 15% soybean oil (series B) or acidification of meal to pH 2.5 (series C), and finally after eradication of Helicobacter pylori (HP) (series D). Studies were carried out without or with the pretreatment with placebo or loxiglumide, a specific antagonist of type A CCK receptors. In series A, the gastric secretion obtained by aspiration technique was measured after secretagogues (MSF, caerulein, GRP or p-gastrin), whereas in series B, C, and D intragastric pH was measured before and after test meal and plasma gastrin, CCK and somatostatin were assayed by specific radioimmunoassays. In healthy subjects, MSF increased gastric acid outputs to about 36% of p-gastrin maximum and treatment with loxiglumide failed to affect this secretion. Standard meal enhanced acid output to about 50% of p-gastrin maximum and raised plasma levels of gastrin, CCK but not somatostatin. The pretreatment with loxiglumide resulted in further increase both in gastric acid secretion and plasma gastrin and CCK, while somatostatin level was significantly reduced. Infusion of graded doses of caerulein or GRP resulted in dose-dependent stimulation of gastric acid secretion reaching, respectively, 35% and 25% of p-gastrin maximum. When loxiglumide was added, the acid responses to caerulein and GRP were further increased by 2-3 folds, attaining a peak similar to the p-gastrin maximum. Administration of loxiglumide resulted in a significant increase in plasma gastrin and CCK responses to GRP, whereas plasma somatostatin was not significantly altered. Addition of fat to standard meal prolonged gastric emptying of this meal by about 50% both in healthy subjects and DU patients (series B). Fat in healthy subjects significantly increased and prolonged intragastric pH after the meal while reducing the increments in plasma gastrin and enhancing plasma CCK without alteration of plasma somatostatin. Pretreatment with loxiglumide significantly reduced postprandial pH from control 4.8 to 2.5 and reversed the changes in pH caused by addition of fat. The increments in plasma gastrin and CCK were markedly augmented, whereas those of somatostatin were attenuated. DU patients showed lower postprandial pH (3.0) in tests with or without fat and higher increments in plasma gastrin. CCK antagonism failed to affect significantly the pH profile or the increments in plasma gastrin or CCK. CCK antagonism failed to affect significantly the pH profile or the increments in plasma gastrin. Intragastric application of standard meal of pH 3.0 in healthy subjects and DU patients (series C) resulted in significantly lower median 3 h intragastric pH as compared to that after meal of pH 6.5. After pretreatment with loxiglumide, the median pH after meals of both pHs was significantly lower in healthy subjects but not in DU patients. This reduction in pH was accompanied by more pronounced increase in plasma gastrin response to a meal of pH 6.5 only in healthy controls but not in DU subjects and by a significant increase in plasma CCK and decrease in plasma somatostatin.
Time-dependent spectroscopy of plasma plume under laser welding conditions
NASA Astrophysics Data System (ADS)
Hoffman, Jacek; Szymanski, Zygmunt
2004-07-01
Momentary emission spectra of iron and argon lines were measured in a plasma plume induced during welding with a continuous wave CO2 laser. Time-dependent spectra were registered using a fast gate, lens coupled microchannel plate image intensifier placed between a spectrograph and a 1254 silicon intensified target detector connected to an optical multichannel analyser. The results, together with the analysis of the colour images from a fast camera, show that in the case when argon is the shielding gas, two plasmas exist: the argon plasma and the iron plasma. It has been found that during strong bursts the plasma plume over the keyhole consists mainly of metal vapour, not being diluted by the shielding gas. No apparent mixing of the metal vapour and the shielding gas has been observed. The space-averaged electron densities determined from the Stark broadening of the 7503.87, 7514.65 Å Ar I lines amounts to (0.75-1.05) × 1023 m-3 depending on the distance from the surface. Assuming that argon is not mixed with the metal vapour and is in local thermodynamic equilibrium these electron densities correspond to the temperatures of 12-13 kK. At the peaks of strong vapour bursts the space-averaged electron densities determined from the Stark broadening of the 5383.37 Å Fe I line are (0.6-1) × 1023 m-3. Numerical simulations showed that the maximum densities in the plasma centre are considerably higher and amount to ~1.8 × 1023 m-3 and ~2.45 × 1023 m-3 in the case of the argon and metal plasma, respectively. Consequently the absorption of the laser beam in the plasma plume amounts to ~5% of the beam power in the case of argon and 10% in the case of metal plasma.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, De-Zheng; Wang, Wen-Chun; Zhang, Shuai
2013-05-13
Room temperature homogenous dielectric barrier discharge plasma with high instantaneous energy efficiency is acquired by using nanosecond pulse voltage with 20-200 ns tunable pulse width. Increasing the voltage pulse width can lead to the generation of regular and stable multiple current peaks in each discharge sequence. When the voltage pulse width is 200 ns, more than 5 organized current peaks can be observed under 26 kV peak voltage. Investigation also shows that the organized multiple current peaks only appear in homogenous discharge mode. When the discharge is filament mode, organized multiple current peaks are replaced by chaotic filament current peaks.
Blair, D; Rumack, B H
1977-01-01
We describe a capillary-sampling method for serum or plasma acetaminophen by cation-exchange chromatography. As little as 1.5 mul of plasma or serum and an equal volume of the internal standard (N-butyryl-p-aminophenol) were run, with a precision of +/- 5% between duplicates. Acetaminophen and the internal standard chromatographed in 32 and 50 min, respectively, distinct from intrinsic plasma peaks and peaks caused by other medications.
Characterization of an atmospheric pressure air plasma source for polymer surface modification
NASA Astrophysics Data System (ADS)
Yang, Shujun; Tang, Jiansheng
2013-10-01
An atmospheric pressure air plasma source was generated through dielectric barrier discharge (DBD). It was used to modify polyethyleneterephthalate (PET) surfaces with very high throughput. An equivalent circuit model was used to calculate the peak average electron density. The emission spectrum from the plasma was taken and the main peaks in the spectrum were identified. The ozone density in the down plasma region was estimated by Absorption Spectroscopy. NSF and ARC-ODU
Walker, O; Dawodu, A H; Adeyokunnu, A A; Salako, L A; Alvan, G
1983-01-01
Twelve children with acute falciparum malaria were treated with 25 mg/kg chloroquine orally in three divided doses at 24 h intervals. Concentrations of chloroquine and its metabolite, desethylchloroquine, were measured in plasma from the beginning of treatment for up to 7 days using a high pressure liquid chromatography (h.p.l.c.) technique. Chloroquine was detectable in plasma within 30 min of giving the drug. Peak level was reached in 1-8 h after the first dose of 10 mg/kg and the peak concentrations ranged between 65 and 263 ng/ml. Chloroquine concentration declined slowly in plasma after stopping drug administration so that the concentration at the seventh day was 37.5% of the concentration on the third day. The apparent half-life was 3-4 days. Desethylchloroquine was detectable in plasma within 30 min of giving chloroquine and peak levels were reached in 2-12 h. Peak concentration after the first dose of chloroquine ranged between 9 and 62 ng/ml. Desethylchloroquine was also slowly cleared from plasma and mean concentration at the end of 7 days was 49% of the mean concentration at the end of 3 days. PMID:6661356
Ma, Yan; Li, Peibo; Chen, Dawei; Fang, Tiezheng; Li, Haitian; Su, Weiwei
2006-01-13
A highly sensitive and specific electrospray ionization (ESI) liquid chromatography-tandem mass spectrometry (LC/MS/MS) method for quantitation of naringenin (NAR) and an explanation for the double peaks phenomenon was developed and validated. NAR was extracted from rat plasma and tissues along with the internal standard (IS), hesperidin, with ethyl acetate. The analytes were analyzed in the multiple-reaction-monitoring (MRM) mode as the precursor/product ion pair of m/z 273.4/151.3 for NAR and m/z 611.5/303.3 for the IS. The assay was linear over the concentration range of 5-2500 ng/mL. The lower limit quantification was 5 ng/mL, available for plasma pharmacokinetics of NAR in rats. Accuracy in within- and between-run precisions showed good reproducibility. When NAR was administered orally, only little and predominantly its glucuronidation were into circulation in the plasma. There existed double peaks phenomenon in plasma concentration-time curve leading to the relatively slow elimination of NAR in plasma. The results showed that there was a linear relationship between the AUC of total NAR and dosages. And the double peaks are mainly due to enterohepatic circulation.
Nieć, Dawid; Kunicki, Paweł K
2015-10-01
Measurements of plasma concentrations of free normetanephrine (NMN), metanephrine (MN) and methoxytyramine (MTY) constitute the most diagnostically accurate screening test for pheochromocytomas and paragangliomas. The aim of this article is to present the results from a validation of an analytical method utilizing high performance liquid chromatography with coulometric detection (HPLC-CD) for quantifying plasma free NMN, MN and MTY. Additionally, peak integration by height and area and the use of one calibration curve for all batches or individual calibration curve for each batch of samples was explored as to determine the optimal approach with regard to accuracy and precision. The method was validated using charcoal stripped plasma spiked with solutions of NMN, MN, MTY and internal standard (4-hydroxy-3-methoxybenzylamine) with the exception of selectivity which was evaluated by analysis of real plasma samples. Calibration curve performance, accuracy, precision and recovery were determined following both peak-area and peak-height measurements and the obtained results were compared. The most accurate and precise method of calibration was evaluated by analyzing quality control samples at three concentration levels in 30 analytical runs. The detector response was linear over the entire tested concentration range from 10 to 2000pg/mL with R(2)≥0.9988. The LLOQ was 10pg/mL for each analyte of interest. To improve accuracy for measurements at low concentrations, a weighted (1/amount) linear regression model was employed, which resulted in inaccuracies of -2.48 to 9.78% and 0.22 to 7.81% following peak-area and peak-height integration, respectively. The imprecisions ranged from 1.07 to 15.45% and from 0.70 to 11.65% for peak-area and peak-height measurements, respectively. The optimal approach to calibration was the one utilizing an individual calibration curve for each batch of samples and peak-height measurements. It was characterized by inaccuracies ranging from -3.39 to +3.27% and imprecisions from 2.17 to 13.57%. The established HPLC-CD method enables accurate and precise measurements of plasma free NMN, MN and MTY with reasonable selectivity. Preparing calibration curve based on peak-height measurements for each batch of samples yields optimal accuracy and precision. Copyright © 2015. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Schmitz, O.; Becoulet, M.; Cahyna, P.; Evans, T. E.; Feng, Y.; Frerichs, H.; Loarte, A.; Pitts, R. A.; Reiser, D.; Fenstermacher, M. E.; Harting, D.; Kirschner, A.; Kukushkin, A.; Lunt, T.; Saibene, G.; Reiter, D.; Samm, U.; Wiesen, S.
2016-06-01
Results from three-dimensional modeling of plasma edge transport and plasma-wall interactions during application of resonant magnetic perturbation (RMP) fields for control of edge-localized modes in the ITER standard 15 MA Q = 10 H-mode are presented. The full 3D plasma fluid and kinetic neutral transport code EMC3-EIRENE is used for the modeling. Four characteristic perturbed magnetic topologies are considered and discussed with reference to the axisymmetric case without RMP fields. Two perturbation field amplitudes at full and half of the ITER ELM control coil current capability using the vacuum approximation are compared to a case including a strongly screening plasma response. In addition, a vacuum field case at high q 95 = 4.2 featuring increased magnetic shear has been modeled. Formation of a three-dimensional plasma boundary is seen for all four perturbed magnetic topologies. The resonant field amplitudes and the effective radial magnetic field at the separatrix define the shape and extension of the 3D plasma boundary. Opening of the magnetic field lines from inside the separatrix establishes scrape-off layer-like channels of direct parallel particle and heat flux towards the divertor yielding a reduction of the main plasma thermal and particle confinement. This impact on confinement is most accentuated at full RMP current and is strongly reduced when screened RMP fields are considered, as well as for the reduced coil current cases. The divertor fluxes are redirected into a three-dimensional pattern of helical magnetic footprints on the divertor target tiles. At maximum perturbation strength, these fingers stretch out as far as 60 cm across the divertor targets, yielding heat flux spreading and the reduction of peak heat fluxes by 30%. However, at the same time substantial and highly localized heat fluxes reach divertor areas well outside of the axisymmetric heat flux decay profile. Reduced RMP amplitudes due to screening or reduced RMP coil current yield a reduction of the width of the divertor flux spreading to about 20-25 cm and cause increased peak heat fluxes back to values similar to those in the axisymmetric case. The dependencies of these features on the divertor recycling regime and the perpendicular transport assumptions, as well as toroidal averaged effects mimicking rotation of the RMP field, are discussed in the paper.
Magnitude and frequency of floods in Nebraska
Beckman, Emil W.
1976-01-01
Observed maximum flood peaks at 303 gaging stations with 13 or more years of record and significant peaks at 57 short-term stations and 31 miscellaneous sites are useful in designing flood-control works for maximum safety from flood damage. Comparison is made with maximum observed floods in the United States.
Nicotine Delivery and Vaping Behavior During ad Libitum E-cigarette Access.
St Helen, Gideon; Ross, Kathryn C; Dempsey, Delia A; Havel, Christopher M; Jacob, Peyton; Benowitz, Neal L
2016-10-01
To characterize vaping behavior and nicotine intake during ad libitum e-cigarette access. Thirteen adult e-cigarette users had 90 minutes of videotaped ad libitum access to their usual e-cigarette. Plasma nicotine was measured before and every 15 minutes after the first puff; subjective effects were measured before and after the session. Average puff duration and interpuff interval were 3.5±1.4 seconds (±SD) and 118±141 seconds, respectively. 12% of puffs were unclustered puffs while 43%, 28%, and 17% were clustered in groups of 2-5, 6-10, and >10 puffs, respectively. On average, 4.0±3.3 mg of nicotine was inhaled; the maximum plasma nicotine concentration (C max ) was 12.8±8.5 ng/mL. Among the 8 tank users, number of puffs was positively correlated with amount of nicotine inhaled, C max , and area under the plasma nicotine concentration-time curve (AUC 0 → 90min ) while interpuff interval was negatively correlated with C max and AUC 0 → 90 . Vaping patterns differ from cigarette smoking. Plasma nicotine levels were consistent with intermittent dosing of nicotine from e-cigarettes compared to the more bolus dosing from cigarettes. Differences in delivery patterns and peak levels of nicotine achieved could influence the addictiveness of e-cigarettes compared to conventional cigarettes.
Global conditions in the solar corona from 2010 to 2017
Morgan, Huw; Taroyan, Youra
2017-01-01
Through reduction of a huge data set spanning 2010–2017, we compare mean global changes in temperature, emission measure (EM), and underlying photospheric magnetic field of the solar corona over most of the last activity cycle. The quiet coronal mean temperature rises from 1.4 to 1.8 MK, whereas EM increases by almost a factor of 50% from solar minimum to maximum. An increased high-temperature component near 3 MK at solar maximum drives the increase in quiet coronal mean temperature, whereas the bulk of the plasma remains near 1.6 MK throughout the cycle. The mean, spatially smoothed magnitude of the quiet Sun magnetic field rises from 1.6 G in 2011 to peak at 2.0 G in 2015. Active region conditions are highly variable, but their mean remains approximately constant over the cycle, although there is a consistent decrease in active region high-temperature emission (near 3 MK) between the peak of solar maximum and present. Active region mean temperature, EM, and magnetic field magnitude are highly correlated. Correlation between sunspot/active region area and quiet coronal conditions shows the important influence of decaying sunspots in driving global changes, although we find no appreciable delay between changes in active region area and quiet Sun magnetic field strength. The hot coronal contribution to extreme ultraviolet (EUV) irradiance is dominated by the quiet corona throughout most of the cycle, whereas the high variability is driven by active regions. Solar EUV irradiance cannot be predicted accurately by sunspot index alone, highlighting the need for continued measurements. PMID:28740861
Experimental investigation on frequency characteristics of plasma synthetic jets
NASA Astrophysics Data System (ADS)
Zong, Haohua; Kotsonis, Marios
2017-11-01
The performance of a two-electrode plasma synthetic jet actuator (PSJA) is investigated for a wide range of dimensionless actuation frequencies ( f*) using high-speed phase-locked particle imaging velocimetry measurements. The jet-induced velocity fields in the axisymmetric plane are measured during both transient and steady working stages of the PSJA. When f* increases, the jet duration time (Tjet) is reduced, while the peak suction velocity (Us) increases consistently. Three integral parameters including the total expelled gas mass, impulse, and issued mechanical energy also decline considerably with increasing frequency, which is shown to relate to both the reduced cavity density and the decreasing jet duration. Theoretical analysis reveals that the mean cavity density decreases monotonically with the square root of the discharge frequency. The decreasing rate is inversely proportional to a thermal cut-off frequency ( fc, 210 Hz for the current study), which scales with the convective heat transfer coefficient between the actuator cavity walls and the cavity gas, as well as the area of the cavity internal surface. In the time-averaged velocity fields, the jet centreline velocity (U¯ c) exhibits a local maximum in the axial coordinate. The nondimensional maximum centreline velocity reduces with increasing frequency of operation. The jet spreading rate of the plasma synthetic jets (PSJs) decreases from 0.14 to 0.09 with increasing frequency. During the transient working stage of a PSJ, the exit velocity trace elapses 20 successive actuation cycles to stabilize. In contrast to the exit velocity, approximately 130 cycles are needed for the mean cavity density/temperature to reach steady values.
Application of high-quality SiO2 grown by multipolar ECR source to Si/SiGe MISFET
NASA Technical Reports Server (NTRS)
Sung, K. T.; Li, W. Q.; Li, S. H.; Pang, S. W.; Bhattacharya, P. K.
1993-01-01
A 5 nm-thick SiO2 gate was grown on an Si(p+)/Si(0.8)Ge(0.2) modulation-doped heterostructure at 26 C with an oxygen plasma generated by a multipolar electron cyclotron resonance source. The ultrathin oxide has breakdown field above 12 MV/cm and fixed charge density about 3 x 10 exp 10/sq cm. Leakage current as low as 1/micro-A was obtained with the gate biased at 4 V. The MISFET with 0.25 x 25 sq m gate shows maximum drain current of 41.6 mA/mm and peak transconductance of 21 mS/mm.
NASA Astrophysics Data System (ADS)
Sharma, A.; Tibai, Z.; Hebling, J.; Fülöp, J. A.
2018-03-01
Laser-driven proton acceleration from a micron-sized cryogenic hydrogen microjet target is investigated using multi-dimensional particle-in-cell simulations. With few-cycle (20-fs) ultraintense (2-PW) laser pulses, high-energy quasi-monoenergetic proton acceleration is predicted in a new regime. A collisionless shock-wave acceleration mechanism influenced by Weibel instability results in a maximum proton energy as high as 160 MeV and a quasi-monoenergetic peak at 80 MeV for 1022 W/cm2 laser intensity with controlled prepulses. A self-generated strong quasi-static magnetic field is also observed in the plasma, which modifies the spatial distribution of the proton beam.
Radiated Power and Impurity Concentrations in the EXTRAP-T2R Reversed-Field Pinch
NASA Astrophysics Data System (ADS)
Corre, Y.; Rachlew, E.; Cecconello, M.; Gravestijn, R. M.; Hedqvist, A.; Pégourié, B.; Schunke, B.; Stancalie, V.
2005-01-01
A numerical and experimental study of the impurity concentration and radiation in the EXTRAP-T2R device is reported. The experimental setup consists of an 8-chord bolometer system providing the plasma radiated power and a vacuum-ultraviolet spectrometer providing information on the plasma impurity content. The plasma emissivity profile as measured by the bolometric system is peaked in the plasma centre. A one dimensional Onion Skin Collisional-Radiative model (OSCR) has been developed to compute the density and radiation distributions of the main impurities. The observed centrally peaked emissivity profile can be reproduced by OSCR simulations only if finite particle confinement time and charge-exchange processes between plasma impurities and neutral hydrogen are taken into account. The neutral hydrogen density profile is computed with a recycling code. Simulations show that recycling on metal first wall such as in EXTRAP-T2R (stainless steel vacuum vessel and molybdenum limiters) is compatible with a rather high neutral hydrogen density in the plasma centre. Assuming an impurity concentration of 10% for oxygen and 3% for carbon compared with the electron density, the OSCR calculation including lines and continuum emission reproduces about 60% of the total radiated power with a similarly centrally peaked emissivity profile. The centrally peaked emissivity profile is due to low ionisation stages and strongly radiating species in the plasma core, mainly O4+ (Be-like) and C3+ Li-like.
Pharmacokinetics and Pharmacodynamics of Lysergic Acid Diethylamide in Healthy Subjects.
Dolder, Patrick C; Schmid, Yasmin; Steuer, Andrea E; Kraemer, Thomas; Rentsch, Katharina M; Hammann, Felix; Liechti, Matthias E
2017-10-01
Lysergic acid diethylamide (LSD) is used recreationally and in clinical research. The aim of the present study was to characterize the pharmacokinetics and exposure-response relationship of oral LSD. We analyzed pharmacokinetic data from two published placebo-controlled, double-blind, cross-over studies using oral administration of LSD 100 and 200 µg in 24 and 16 subjects, respectively. The pharmacokinetics of the 100-µg dose is shown for the first time and data for the 200-µg dose were reanalyzed and included. Plasma concentrations of LSD, subjective effects, and vital signs were repeatedly assessed. Pharmacokinetic parameters were determined using compartmental modeling. Concentration-effect relationships were described using pharmacokinetic-pharmacodynamic modeling. Geometric mean (95% confidence interval) maximum plasma concentration values of 1.3 (1.2-1.9) and 3.1 (2.6-4.0) ng/mL were reached 1.4 and 1.5 h after administration of 100 and 200 µg LSD, respectively. The plasma half-life was 2.6 h (2.2-3.4 h). The subjective effects lasted (mean ± standard deviation) 8.2 ± 2.1 and 11.6 ± 1.7 h for the 100- and 200-µg LSD doses, respectively. Subjective peak effects were reached 2.8 and 2.5 h after administration of LSD 100 and 200 µg, respectively. A close relationship was observed between the LSD concentration and subjective response within subjects, with moderate counterclockwise hysteresis. Half-maximal effective concentration values were in the range of 1 ng/mL. No correlations were found between plasma LSD concentrations and the effects of LSD across subjects at or near maximum plasma concentration and within dose groups. The present pharmacokinetic data are important for the evaluation of clinical study findings (e.g., functional magnetic resonance imaging studies) and the interpretation of LSD intoxication. Oral LSD presented dose-proportional pharmacokinetics and first-order elimination up to 12 h. The effects of LSD were related to changes in plasma concentrations over time, with no evidence of acute tolerance. NCT02308969, NCT01878942.
Study of ion-gyroscale fluctuations in low-density L-mode plasmas heated by NBI on KSTAR
NASA Astrophysics Data System (ADS)
Lee, W.; Ko, S. H.; Leem, J.; Yun, G. S.; Park, H. K.; Wang, W. X.; Budny, R. V.; Kim, K. W.; Luhmann, N. C., Jr.; The KSTAR Team
2018-04-01
Broadband density fluctuations with peak frequency ranging from 150 to 400 kHz were measured using a multichannel microwave imaging reflectometer in core region of the low-density L-mode plasmas heated by neutral beam injection on KSTAR. These fluctuations have been studied by comparing the dominant mode scales estimated from the measurement with those predicted from linear gyrokinetic simulation. The measured poloidal wavenumbers are qualitatively comparable to those of the ‘fastest growing modes’ from simulations, whereas they are larger than those of the ‘transport-dominant modes’ by about a factor of three. The agreement on wavenumbers between the measurement and linear simulation (for the fastest growing modes) is probably due to sufficiently weak E × B flow shear compared to the maximum linear growth rate. Meanwhile, the transport-dominant modes seem to be related to the fluctuations in lower frequencies (˜80-150 kHz) observed in some of the measurement.
Ranga Rao, A; Raghunath Reddy, R L; Baskaran, V; Sarada, R; Ravishankar, G A
2010-08-11
Of the total carotenoids in respective algal samples, beta-carotene in Spirulina platensis was 69.5%, astaxanthin and its esters in Haematococcus pluvialis was 81.38%, and lutein in Botryococcus braunii was 74.6%. The carotenoids were characterized by mass spectrometry. A time-course study of carotenoids in rats after administration of microalgal biomass showed peak levels in plasma, liver, and eyes at 2, 4, and 6 h, respectively. Beta-carotene accumulation in Spirulina-fed rats was maximum in eye tissues at 6 h. Similarly, levels of astaxanthin and lutein in Haematococcus- and Botryococcus-fed rats were also maximal in eye tissues. Astaxanthin from H. pluvialis showed better bioavailability than beta-carotene and lutein. The antioxidant enzymes, catalase, superoxide dismutase, peroxidase, and TBARS were significantly high in plasma at 2 h and in liver at 4 h, evidently offering protection from free radicals. This study implies that microalgae can be a good source of carotenoids of high bioavailability and nutraceutical value.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pandey, Jeewan C.; Karmakar, Subhajeet, E-mail: jeewan@aries.res.in
2015-02-01
Using XMM-Newton observations, we investigate properties of a flare from the very active but poorly known stellar system 47 Cas. The luminosity at the peak of the flare is found to be 3.54 × 10{sup 30} erg s{sup −1}, which is ∼2 times higher than that at a quiescent state. The quiescent state corona of 47 Cas can be represented by two temperature plasma: 3.7 and 11.0 MK. The time-resolved X-ray spectroscopy of the flare show the variable nature of the temperature, the emission measure, and the abundance. The maximum temperature during the flare is derived as 72.8 MK. Wemore » infer the length of a flaring loop to be 3.3 × 10{sup 10} cm using a hydrodynamic loop model. Using the RGS spectra, the density during the flare is estimated as 4.0 × 10{sup 10} cm{sup −3}. The loop scaling laws are also applied when deriving physical parameters of the flaring plasma.« less
Light impurity transport in JET ILW L-mode plasmas
NASA Astrophysics Data System (ADS)
Bonanomi, N.; Mantica, P.; Giroud, C.; Angioni, C.; Manas, P.; Menmuir, S.; Contributors, JET
2018-03-01
A series of experimental observations of light impurity profiles was carried out in JET (Joint European Torus) ITER-like wall (ILW) L-mode plasmas in order to investigate their transport mechanisms. These discharges feature the presence of 3He, Be, C, N, Ne, whose profiles measured by active Charge Exchange diagnostics are compared with quasi-linear and non-linear gyro-kinetic simulations. The peaking of 3He density follows the electron density peaking, Be and Ne are also peaked, while the density profiles of C and N are flat in the mid plasma region. Gyro-kinetic simulations predict peaked density profiles for all the light impurities studied and at all the radial positions considered, and fail predicting the flat or hollow profiles observed for C and N at mid radius in our cases.
The structural and electrical evolution of graphene by oxygen plasma-induced disorder.
Kim, Dong Chul; Jeon, Dae-Young; Chung, Hyun-Jong; Woo, YunSung; Shin, Jai Kwang; Seo, Sunae
2009-09-16
Evolution of a single graphene layer with disorder generated by remote oxygen plasma irradiation is investigated using atomic force microscopy, Raman spectroscopy and electrical measurement. Gradual changes of surface morphology from planar graphene to isolated granular structure associated with a decrease of transconductance are accounted for by two-dimensional percolative conduction by disorder and the oxygen plasma-induced doping effect. The corresponding evolution of Raman spectra of graphene shows several peculiarities such as a sudden appearance of a saturated D peak followed by a linear decrease in its intensity, a relatively inert characteristic of a D' peak and a monotonic increase of a G peak position as the exposure time to oxygen plasma increases. These are discussed in terms of a disorder-induced change of Raman spectra in the graphite system.
Final Report: Levitated Dipole Experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kesner, Jay; Mauel, Michael
2013-03-10
Since the very first experiments with the LDX, research progress was rapid and significant. Initial experiments were conducted with the high-field superconducting coil suspended by three thin rods. These experiments produced long-pulse, quasi-steady-state microwave discharges, lasting more than 10 s, having peak beta values of 20% [Garnier, Phys. Plasmas, v13, p. 056111, 2006]. High-beta, near steady-state discharges have been maintained in LDX for more than 20 seconds, and this capability makes LDX the longest pulse fusion confinement experiment now operating in the U.S. fusion program. In both supported and levitated configurations, detailed measurements are made of discharge evolution, plasma dynamicsmore » and instability, and the roles of gas fueling, microwave power deposition profiles, and plasma boundary shape. High-temperature plasma is created by multifrequency electron cyclotron resonance heating allowing control of heating profiles. Depending upon neutral fueling rates, the LDX discharges contain a fraction of energetic electrons, with mean energies above 50 keV. Depending on whether or not the superconducting dipole is levitated or supported, the peak thermal electron temperature is estimated to exceed 500 eV and peak densities reach 1.0E18 (1/m3). Several significant discoveries resulted from the routine investigation of plasma confinement with a magnetically-levitated dipole. For the first time, toroidal plasma with pressure approaching the pressure of the confining magnetic field was well-confined in steady-state without a toroidal magnetic field. Magnetic levitation proved to be reliable and is now routine. The dipole's cryostat allows up to three hours of "float time" between re-cooling with liquid helium and providing scientists unprecedented access to the physics of magnetizd plasma. Levitation eliminates field-aligned particle sources and sinks and results in a toroidal, magnetically-confined plasma where profiles are determined by cross-field transport. We find levitation causes the central plasma density to increase dramatically and to significantly improve the confinement of thermal plasma [Boxer, Nature-Physics, v8, p. 949, 2010]. Several diagnostic systems have been used to measure plasma fluctuations, and these appear to represent low-frequency convection that may lead to adiabatic heating and strongly peaked pressure profiles. These experiments are remarkable, and the motivate wide-ranging studies of plasma found in space and confined for fusion energy. In the following report, we describe: (i) observations of the centrally-peaked density profile that appears naturally as a consequence of a strong turbulent pinch, (ii) observations of overall density and pressure increases that suggest large improvements to the thermal electron confinement time result occur during levitation, and (iii) the remarkable properties of low-frequency plasma fluctuations that cause magnetized plasma to "self-organize" into well-confined, centrally-peaked profiles that are relative to fusion and to space.« less
NASA Astrophysics Data System (ADS)
Wu, WenBin; Ren, HaiTao; Peng, ShiXiang; Xu, Yuan; Wen, JiaMei; Zhang, Tao; Zhang, JingFeng; Zhang, AiLin; Sun, Jiang; Guo, ZhiYu; Chen, JiaEr
2018-04-01
A quartz-chamber 2.45 GHz electron cyclotron resonance ion source (ECRIS) was designed for diagnostic purposes at Peking University [Patent Number: ZL 201110026605.4]. This ion source can produce a maximum 84 mA hydrogen ion beam at 50 kV with a duty factor of 10%. The root-mean-square (RMS) emittance of this beam is less than 0.12π mm mrad. In our initial work, the electron temperature and electron density inside the plasma chamber had been measured with the line intensity ratio of noble gases. Based on these results, the atomic and molecular emission spectra of hydrogen were applied to determine the dissociation degree of hydrogen and the vibrational temperature of hydrogen molecules in the ground state, respectively. Measurements were performed at gas pressures from 4×10-4 to 1×10-3 Pa and at input peak RF power ranging from 1000 to 1800 W. The dissociation degree of hydrogen in the range of 0.5%-10% and the vibrational temperature of hydrogen molecules in the ground state in the range of 3500-8500 K were obtained. The plasma processes inside this ECRIS chamber were discussed based on these results.
Hollow structure formation of intense ion beams with sharp edge in background plasmas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu, Zhang-Hu; Wang, You-Nian, E-mail: ynwang@dlut.edu.cn
The transport of intense ion beams with sharp radial beam edge in plasmas has been studied with two-dimensional electromagnetic particle simulations. The initial solid beam evolves into a hollow beam due to the nonlinear sharp transverse force peak in the regions of beam edge. The magnitude and nonlinearity of this peak are enhanced as the ion beam travels further into the plasma, due to the self-consistent interactions between the beam ions and the plasma electrons. This structure formation is shown to be independent on the beam radius.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gul, Banat, E-mail: banatgul@gmail.com; Research Group PLASMANT, Department of Chemistry, University of Antwerp, Universiteitsplein 1, B-2610 Antwerp; Aman-ur-Rehman, E-mail: amansadiq@gmail.com
Fluid model has been applied to perform a comparative study of hydrogen bromide (HBr)/He and HBr/Ar capacitively coupled plasma discharges that are being used for anisotropic etching process. This model has been used to identify the most dominant species in HBr based plasmas. Our simulation results show that the neutral species like H and Br, which are the key player in chemical etching, have bell shape distribution, while ions like HBr{sup +}, Br{sup +}, which play a dominant rule in the physical etching, have double humped distribution and show peaks near electrodes. It was found that the dilution of HBrmore » by Ar and/or He results in an increase in electron density and electron temperature, which results in more ionization and dissociation and hence higher densities of neutral and charged species can be achieved. The ratio of positive ion flux to the neutral flux increases with an increase in additive gas fraction. Compare to HBr/He plasma, the HBr/Ar plasma shows a maximum change in the ion density and flux and hence the etching rate can be considered in the ion-assisted and in the ion-flux etch regime in HBr/Ar discharge. The densities of electron and other dominant species in HBr/Ar plasma are higher than those of HBr/He plasma. The densities and fluxes of the active neutrals and positive ions for etching and subsequently chemical etching versus physical sputtering in HBr/Ar and HBr/He plasmas discharge can be controlled by tuning gas mixture ratio and the desire etching can be achieved.« less
Acute Effects of Lysergic Acid Diethylamide on Circulating Steroid Levels in Healthy Subjects.
Strajhar, P; Schmid, Y; Liakoni, E; Dolder, P C; Rentsch, K M; Kratschmar, D V; Odermatt, A; Liechti, M E
2016-03-01
Lysergic acid diethylamide (LSD) is a serotonin 5-hydroxytryptamine-2A (5-HT2A ) receptor agonist that is used recreationally worldwide. Interest in LSD research in humans waned after the 1970s, although the use of LSD in psychiatric research and practice has recently gained increasing attention. LSD produces pronounced acute psychedelic effects, although its influence on plasma steroid levels over time has not yet been characterised in humans. The effects of LSD (200 μg) or placebo on plasma steroid levels were investigated in 16 healthy subjects using a randomised, double-blind, placebo-controlled, cross-over study design. Plasma concentration-time profiles were determined for 15 steroids using liquid-chromatography tandem mass-spectrometry. LSD increased plasma concentrations of the glucocorticoids cortisol, cortisone, corticosterone and 11-dehydrocorticosterone compared to placebo. The mean maximum concentration of LSD was reached at 1.7 h. Mean peak psychedelic effects were reached at 2.4 h, with significant alterations in mental state from 0.5 h to > 10 h. Mean maximal concentrations of cortisol and corticosterone were reached at 2.5 h and 1.9 h, and significant elevations were observed 1.5-6 h and 1-3 h after drug administration, respectively. LSD also significantly increased plasma concentrations of the androgen dehydroepiandrosterone but not other androgens, progestogens or mineralocorticoids compared to placebo. A close relationship was found between plasma LSD concentrations and changes in plasma cortisol and corticosterone and the psychotropic response to LSD, and no clockwise hysteresis was observed. In conclusion, LSD produces significant acute effects on circulating steroids, especially glucocorticoids. LSD-induced changes in circulating glucocorticoids were associated with plasma LSD concentrations over time and showed no acute pharmacological tolerance. © 2016 British Society for Neuroendocrinology.
Heupel, M R; Whittier, J M; Bennett, M B
1999-10-01
Examination of the reproductive biology of the oviparous epaulette shark, Hemiscyllium ocellatum, was conducted on a wild population. Male sharks were found to reach maturity at between 55-60 cm total length (TL) and female sharks mature around 55 cm TL. Blood samples collected from mature male and female sharks were analyzed for sex steroid hormones to examine seasonal hormone patterns. Plasma samples were analyzed via radioimmunoassay techniques with female samples measured for estradiol, progesterone, and androgen concentrations, and male samples measured for androgen concentrations. Male androgen concentrations showed a single broad peak from July to October with maximum hormone concentrations (60 ng/ml) occurring in August. Male androgen concentrations were lowest in December-February (<20 ng/ml), and appeared to correlate with reproductive activity and water temperature. Female androgen concentrations were an order of magnitude lower than those for males and showed peaks in June (6 ng/ml) and December (8 ng/ml). Estradiol concentrations in females peaked during the months of September-November (0.5 ng/ml) coinciding with the egg laying period. Progesterone concentrations ranged up to 0.5 ng/ml prior to the mating season. Observations of ova size and egg production showed eggs develop in pairs and ova are ovulated at a size of 25-27 mm. Females lay eggs from August to January. Males were observed with swollen claspers from July through December, with the highest amount of sperm storage in the epididymis occurring between August through November. Our observations indicate that epaulette sharks in the waters near Heron Island mate from July through December. J. Exp. Zool. 284:586-594, 1999. Copyright 1999 Wiley-Liss, Inc.
Pre-treatment plasma proteomic markers associated with survival in oesophageal cancer
Kelly, P; Paulin, F; Lamont, D; Baker, L; Clearly, S; Exon, D; Thompson, A
2012-01-01
Background: The incidence of oesophageal adenocarcinoma is increasing worldwide but survival remains poor. Neoadjuvant chemotherapy can improve survival, but prognostic and predictive biomarkers are required. This study built upon preclinical approaches to identify prognostic plasma proteomic markers in oesophageal cancer. Methods: Plasma samples collected before and during the treatment of oesophageal cancer and non-cancer controls were analysed by surface-enhanced laser desorption/ionisation time-of-flight (SELDI-TOF) mass spectroscopy (MS). Protein peaks were identified by MS in tryptic digests of purified fractions. Associations between peak intensities obtained in the spectra and clinical endpoints (survival, disease-free survival) were tested by univariate (Fisher's exact test) and multivariate analysis (binary logistic regression). Results: Plasma protein peaks were identified that differed significantly (P<0.05, ANOVA) between the oesophageal cancer and control groups at baseline. Three peaks, confirmed as apolipoprotein A-I, serum amyloid A and transthyretin, in baseline (pre-treatment) samples were associated by univariate and multivariate analysis with disease-free survival and overall survival. Conclusion: Plasma proteins can be detected prior to treatment for oesophageal cancer that are associated with outcome and merit testing as prognostic and predictive markers of response to guide chemotherapy in oesophageal cancer. PMID:22294182
Pre-treatment plasma proteomic markers associated with survival in oesophageal cancer.
Kelly, P; Paulin, F; Lamont, D; Baker, L; Clearly, S; Exon, D; Thompson, A
2012-02-28
The incidence of oesophageal adenocarcinoma is increasing worldwide but survival remains poor. Neoadjuvant chemotherapy can improve survival, but prognostic and predictive biomarkers are required. This study built upon preclinical approaches to identify prognostic plasma proteomic markers in oesophageal cancer. Plasma samples collected before and during the treatment of oesophageal cancer and non-cancer controls were analysed by surface-enhanced laser desorption/ionisation time-of-flight (SELDI-TOF) mass spectroscopy (MS). Protein peaks were identified by MS in tryptic digests of purified fractions. Associations between peak intensities obtained in the spectra and clinical endpoints (survival, disease-free survival) were tested by univariate (Fisher's exact test) and multivariate analysis (binary logistic regression). Plasma protein peaks were identified that differed significantly (P<0.05, ANOVA) between the oesophageal cancer and control groups at baseline. Three peaks, confirmed as apolipoprotein A-I, serum amyloid A and transthyretin, in baseline (pre-treatment) samples were associated by univariate and multivariate analysis with disease-free survival and overall survival. Plasma proteins can be detected prior to treatment for oesophageal cancer that are associated with outcome and merit testing as prognostic and predictive markers of response to guide chemotherapy in oesophageal cancer.
Liu, Xiang-he; Ye, Chao-xia; Ye, Ji-dan; Shen, Bi-duan; Wang, Chun-yan; Wang, An-li
2014-10-01
The effect of dietary amylose/amylopectin (AM/AP) ratio on growth, feed utilization, digestive enzyme activities, plasma parameters, and postprandial blood glucose responses was evaluated in juvenile obscure puffer, Takifugu obscurus. Five isonitrogenous (430 g kg(-1) crude protein) and isolipidic (90 g kg(-1) crude lipid) diets containing an equal starch level (250 g kg(-1) starch) with different AM/AP ratio diets of 0/25, 3/22, 6/19, 9/16 and 12/13 were formulated. Each experimental diet was fed to triplicate groups (25 fish per tank), twice daily during a period of 60 days. After the growth trial, a postprandial blood response test was carried out. Fish fed diet 6/19 showed best growth, feed efficiency and protein efficiency ratio. Hepatosomatic index, plasma total cholesterol concentration, liver glycogen and lipid content, and gluconokinase, pyruvate kinase and fructose-1,6-bisphosphatase activities were lower in fish fed highest AM/AP diet (12/13) than in fish fed the low-amylose diets. Activities of liver and intestinal trypsin in fish fed diet 3/22 and diet 6/19 were higher than in fish fed diet 9/16 and diet 12/13. Activities of liver and intestinal amylase and intestinal lipase, and starch digestibility were negatively correlated with dietary AM/AP ratio. Fish fed diet 3/22 and diet 6/19 showed higher plasma total amino acid concentration than fish fed the other diets, while plasma urea nitrogen concentration and activities of alanine aminotransferase and aspartate aminotransferase showed the opposite trend. Equal values were found for viscerosomatic index and condition factor, whole body and muscle composition, plasma high-density and low-density lipoprotein cholesterol concentrations, and activities of lipase and hexokinase and glucose-6-phosphatase in liver. Postprandial plasma glucose and triglyceride peak value of fish fed diet 12/13 were lower than in fish fed the low-amylose diets, and the peak time of plasma glucose was later than in fish fed the other diets. Plasma glucose and triglyceride concentrations showed a significant difference at 2 and 4 h after a meal and varied between dietary treatments. According to regression analysis of weight gain against dietary AM/AP ratio, the optimum dietary AM/AP ratio for maximum growth of obscure puffer was 0.25. The present result indicates that dietary AM/AP ratio could affect growth performance and feed utilization, some plasma parameters, digestive enzyme as well as hepatic glucose metabolic enzyme activities in juvenile obscure puffer.
NASA Astrophysics Data System (ADS)
Mazurkiewicz, Karolina; Skotnicki, Marcin
2018-02-01
The paper presents the results of analysis of the influence of the maximum intensity (peak) location in the synthetic hyetograph and rainfall duration on the maximum outflow from urban catchment. For the calculation Chicago hyetographs with a duration from 15 minutes to 180 minutes and peak location between 20% and 50% of the total rainfall duration were design. Runoff simulation was performed using the SWMM5 program for three models of urban catchment with area from 0.9 km2 to 6.7 km2. It was found that the increase in the rainfall peak location causes the increase in the maximum outflow up to 17%. For a given catchment the greatest maximum outflow is generated by the rainfall, which time to peak corresponds to the flow time through the catchment. Presented results may be useful for choosing the rainfall parameters for storm sewer systems modeling.
NASA Astrophysics Data System (ADS)
Hu, S. X.; Gao, R.; Ding, Y.; Collins, L. A.; Kress, J. D.
2017-04-01
Using density-functional theory-based molecular-dynamics simulations, we have investigated the equation of state for silicon in a wide range of plasma density and temperature conditions of ρ =0.001 -500 g /c m3 and T =2000 -108K . With these calculations, we have established a first-principles equation-of-state (FPEOS) table of silicon for high-energy-density (HED) plasma simulations. When compared with the widely used SESAME-EOS model (Table 3810), we find that the FPEOS-predicted Hugoniot is ˜20% softer; for off-Hugoniot plasma conditions, the pressure and internal energy in FPEOS are lower than those of SESAME EOS for temperatures above T ≈ 1-10 eV (depending on density), while the former becomes higher in the low-T regime. The pressure difference between FPEOS and SESAME 3810 can reach to ˜50%, especially in the warm-dense-matter regime. Implementing the FPEOS table of silicon into our hydrocodes, we have studied its effects on Si-target implosions. When compared with the one-dimensional radiation-hydrodynamics simulation using the SESAME 3810 EOS model, the FPEOS simulation showed that (1) the shock speed in silicon is ˜10% slower; (2) the peak density of an in-flight Si shell during implosion is ˜20% higher than the SESAME 3810 simulation; (3) the maximum density reached in the FPEOS simulation is ˜40% higher at the peak compression; and (4) the final areal density and neutron yield are, respectively, ˜30% and ˜70% higher predicted by FPEOS versus the traditional simulation using SESAME 3810. All of these features can be attributed to the larger compressibility of silicon predicted by FPEOS. These results indicate that an accurate EOS table, like the FPEOS presented here, could be essential for the precise design of targets for HED experiments.
Hu, S. X.; Gao, R.; Ding, Y.; ...
2017-04-21
Using density-functional theory–based molecular-dynamics simulations, we have investigated the equation of state for silicon in a wide range of plasma density and temperature conditions of ρ=0.001–500g/cm 3 and T=2000–10 8K. With these calculations, we have established a first-principles equation-of-state (FPEOS) table of silicon for high-energy-density (HED) plasma simulations. When compared with the widely used SESAME-EOS model (Table 3810), we find that the FPEOS-predicted Hugoniot is ~20% softer; for off-Hugoniot plasma conditions, the pressure and internal energy in FPEOS are lower than those of SESAME EOS for temperatures above T ≈ 1–10 eV (depending on density), while the former becomes highermore » in the low- T regime. The pressure difference between FPEOS and SESAME 3810 can reach to ~50%, especially in the warm-dense-matter regime. Implementing the FPEOS table of silicon into our hydrocodes, we have studied its effects on Si-target implosions. When compared with the one-dimensional radiation-hydrodynamics simulation using the SESAME 3810 EOS model, the FPEOS simulation showed that (1) the shock speed in silicon is ~10% slower; (2) the peak density of an in-flight Si shell during implosion is ~20% higher than the SESAME 3810 simulation; (3) the maximum density reached in the FPEOS simulation is ~40% higher at the peak compression; and (4) the final areal density and neutron yield are, respectively, ~30% and ~70% higher predicted by FPEOS versus the traditional simulation using SESAME 3810. All of these features can be attributed to the larger compressibility of silicon predicted by FPEOS. Furthermore, these results indicate that an accurate EOS table, like the FPEOS presented here, could be essential for the precise design of targets for HED experiments.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu, S. X.; Gao, R.; Ding, Y.
Using density-functional theory–based molecular-dynamics simulations, we have investigated the equation of state for silicon in a wide range of plasma density and temperature conditions of ρ=0.001–500g/cm 3 and T=2000–10 8K. With these calculations, we have established a first-principles equation-of-state (FPEOS) table of silicon for high-energy-density (HED) plasma simulations. When compared with the widely used SESAME-EOS model (Table 3810), we find that the FPEOS-predicted Hugoniot is ~20% softer; for off-Hugoniot plasma conditions, the pressure and internal energy in FPEOS are lower than those of SESAME EOS for temperatures above T ≈ 1–10 eV (depending on density), while the former becomes highermore » in the low- T regime. The pressure difference between FPEOS and SESAME 3810 can reach to ~50%, especially in the warm-dense-matter regime. Implementing the FPEOS table of silicon into our hydrocodes, we have studied its effects on Si-target implosions. When compared with the one-dimensional radiation-hydrodynamics simulation using the SESAME 3810 EOS model, the FPEOS simulation showed that (1) the shock speed in silicon is ~10% slower; (2) the peak density of an in-flight Si shell during implosion is ~20% higher than the SESAME 3810 simulation; (3) the maximum density reached in the FPEOS simulation is ~40% higher at the peak compression; and (4) the final areal density and neutron yield are, respectively, ~30% and ~70% higher predicted by FPEOS versus the traditional simulation using SESAME 3810. All of these features can be attributed to the larger compressibility of silicon predicted by FPEOS. Furthermore, these results indicate that an accurate EOS table, like the FPEOS presented here, could be essential for the precise design of targets for HED experiments.« less
Zhang, Qi; Li, Wei; Lin, Da-Chao; He, Ning; Duan, Yun
2011-01-30
The aim of this paper is to provide new experimental data of the minimum ignition energy (MIE) of gaseous nitromethane/air mixtures to discuss the explosion pressure and the flame temperature as a function of nitromethane concentration. Observations on the influence of nitromethane concentration on combustion pressure and temperature through the pressure and temperature measure system show that peak temperature (the peak of combustion temperature wave) is always behind peak pressure (the peak of the combustion pressure wave) in arrival time, the peak combustion pressure of nitromethane increases in the range of its volume fraction 10-40% as the concentration of nitromethane increases, and it slightly decreases in the range of 40-50%. The maximum peak pressure is equal to 0.94 MPa and the minimum peak pressure 0.58 MPa. Somewhat similar to the peak pressure, the peak combustion temperature increases with the volume fraction of nitromethane in the range of 10-40%, and slightly decreases in 40-50%. The maximum peak temperature is 1340 °C and the minimum 860 °C. The combustion temperature rise rate increases with the concentration of nitromethane in 10-30%, while decreases in 30-50% and its maximum value of combustion temperature rise rate in 10-50% is 4200 °C/s at the volume fraction of 30%. Influence of the concentration of nitromethane on the combustion pressure rise rate is relatively complicated, and the maximum value of rise rate of combustion pressure wave in 10-50% is 11 MPa/s at the concentration 20%. Copyright © 2010 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Felker, B.; Allen, S.; Bell, H.
1993-10-06
The MTX explored the plasma heating effects of 140 GHz microwaves from both Gyrotrons and from the IMP FEL wiggler. The Gyrotron was long pulse length (0.5 seconds maximum) and the FEL produced short-pulse length, high-peak power, single and burst modes of 140 GHZ microwaves. Full-power operations of the IMP FEL wiggler were commenced in April of 1992 and continued into October of 1992. The Experimental Test Accelerator H (ETA-II) provided a 50-nanosecond, 6-MeV, 2--3 kAmp electron beam that was introduced co-linear into the IMP FEL with a 140 GHz Gyrotron master oscillator (MO). The FEL was able to amplifymore » the MO signal from approximately 7 kW to peaks consistently in the range of 1--2 GW. This microwave pulse was transmitted into the MTX and allowed the exploration of the linear and non-linear effects of short pulse, intense power in the MTX plasma. Single pulses were used to explore and gain operating experience in the parameter space of the IMP FEL, and finally evaluate transmission and absorption in the MTX. Single-pulse operations were repeatable. After the MTX was shut down burst-mode operations were successful at 2 kHz. This paper will describe the IMP FEL, Microwave Transmission System to MTX, the diagnostics used for calorimetric measurements, and the operations of the entire Microwave system. A discussion of correlated and uncorrelated errors that affect FEL performance will be made Linear and non-linear absorption data of the microwaves in the MTX plasma will be presented.« less
Focusing of shock waves induced by optical breakdown in water
Sankin, Georgy N.; Zhou, Yufeng; Zhong, Pei
2008-01-01
The focusing of laser-generated shock waves by a truncated ellipsoidal reflector was experimentally and numerically investigated. Pressure waveform and distribution around the first (F1) and second foci (F2) of the ellipsoidal reflector were measured. A neodymium doped yttrium aluminum garnet laser of 1046 nm wavelength and 5 ns pulse duration was used to create an optical breakdown at F1, which generates a spherically diverging shock wave with a peak pressure of 2.1–5.9 MPa at 1.1 mm stand-off distance and a pulse width at half maximum of 36–65 ns. Upon reflection, a converging shock wave is produced which, upon arriving at F2, has a leading compressive wave with a peak pressure of 26 MPa and a zero-crossing pulse duration of 0.1 μs, followed by a trailing tensile wave of −3.3 MPa peak pressure and 0.2 μs pulse duration. The −6 dB beam size of the focused shock wave field is 1.6×0.2 mm2 along and transverse to the shock wave propagation direction. Formation of elongated plasmas at high laser energy levels limits the increase in the peak pressure at F2. General features in the waveform profile of the converging shock wave are in qualitative agreement with numerical simulations based on the Hamilton model. PMID:18537359
Tarandovskiy, Ivan D.; Artemenko, Elena O.; Panteleev, Mikhail A.; Sinauridze, Elena I.; Ataullakhanov, Fazoil I.
2013-01-01
Background Thrombin generation assay is a convenient and widely used method for analysis of the blood coagulation system status. Thrombin generation curve (TGC) is usually bell-shaped with a single peak, but there are exceptions. In particular, TGC in platelet-rich plasma (PRP) can sometimes have two peaks. Objective We sought to understand the mechanism underlying the occurrence of two peaks in the PRP thrombin generation curve. Methods Tissue factor-induced thrombin generation in PRP and platelet-poor plasma (PPP) was monitored using continuous measurement of the hydrolysis rate of the thrombin-specific fluorogenic substrate Z-Gly-Gly-Arg-AMC. Expression of phosphatidylserine (PS) and CD62P on the surface of activated platelets was measured by flow cytometry using corresponding fluorescently labeled markers. Results The addition of the P2Y12 receptor antagonist MeS-AMP (160 µM), 83 nM prostaglandin E1 (PGE1), or 1.6% DMSO to PRP caused the appearance of two peaks in the TGC. The PS exposure after thrombin activation on washed platelets in a suspension supplemented with DMSO, PGE1 or MeS-AMP was delayed, which could indicate mechanism of the second peak formation. Supplementation of PRP with 1.6% DMSO plus 830 nM PGE1 mediated the disappearance of the second peak and decreased the amplitude of the first peak. Increasing the platelet concentration in the PRP promoted the consolidation of the two peaks into one. Conclusions Procoagulant tenase and prothrombinase complexes in PRP assemble on phospholipid surfaces containing PS of two types - plasma lipoproteins and the surface of activated platelets. Thrombin generation in the PRP can be two-peaked. The second peak appears in the presence of platelet antagonists as a result of delayed PS expression on platelets, which leads to delayed assembly of the membrane-dependent procoagulant complexes and a second wave of thrombin generation. PMID:23405196
Liao, Wei; Hua, Xue-Ming; Zhang, Wang; Li, Fang
2014-05-01
In the present paper, the authors calculated the plasma's peak electron temperatures under different heat source separation distance in laser- pulse GMAW hybrid welding based on Boltzmann spectrometry. Plasma's peak electron densities under the corresponding conditions were also calculated by using the Stark width of the plasma spectrum. Combined with high-speed photography, the effect of heat source separation distance on electron temperature and electron density was studied. The results show that with the increase in heat source separation distance, the electron temperatures and electron densities of laser plasma did not changed significantly. However, the electron temperatures of are plasma decreased, and the electron densities of are plasma first increased and then decreased.
Veenhuis, Jack E.
2002-01-01
In June of 1977, the La Mesa wildfire burned 15,270 acres in and around Frijoles Canyon in Bandelier National Monument and the adjacent Santa Fe National Forest, New Mexico. The Dome wildfire in April of 1996 in Bandelier National Monument burned 16,516 acres in Capulin Canyon and the surrounding Dome Wilderness area. Both watersheds are characterized by abundant and extensive archeological sites that could be affected by increased runoff and accelerated rates of erosion, which typically occur after a wildfire. The U.S. Geological Survey in cooperation with the National Park Service monitored the wildfires' effects on streamflow in both canyons. The magnitude of large stormflows increased dramatically after these wildfires; peak flows at the most downstream streamflow-gaging station in Frijoles and Capulin Canyons increased to about 160 times the maximum recorded flood prior to the fire. Maximum peak flow was 3,030 cubic feet per second at the gaging station in Frijoles Canyon (drainage area equals 18.1 square miles) and 3,630 cubic feet per second at the most downstream crest-stage gage in Capulin Canyon (drainage area equals 14.1 square miles). The pre-fire maximum peak flow recorded in these two canyons was 19 and an estimated 25 cubic feet per second, respectively. As vegetation reestablished itself during the second year, the post-fire annual maximum peak flow decreased to about 10 to 15 times the pre-fire annual maximum peak flow. During the third year, maximum annual peak flows decreased to about three to five times the pre-fire maximum peak flow. In the 22 years since the La Mesa wildfire, flood magnitudes have not completely returned to pre-fire size. Post-fire flood magnitudes in Frijoles and Capulin Canyons do not exceed the maximum floods per drainage area for physiographic regions 5 and 6 in New Mexico. For a burned watershed, however, the peak flows that occur after a wildfire are several orders of magnitude larger than normal forested watershed peak flows. The frequency of larger stormflows also increased in response to the effects of the wildfires in both canyons. In Frijoles Canyon, the number of peak stormflows greater than the pre-fire maximum flow of 19 cubic feet per second was 15 in 1977, 9 in 1978, and 5 in 1979, which is about the magnitude of the maximum pre-fire peak flow in both canyons. Again the hydrologic effects of a wildfire seem to be more pronounced for the 3 years following the date of the fire. Likewise, larger peakflows occurred more frequently in Capulin Canyon for the first 3 years after the 1996 wildfire. Median suspended-sediment concentrations in samples collected in Frijoles Canyon in 1977 were 1,330 milligrams per liter; median concentrations were 16 milligrams per liter after the watershed stabilized in 1993-95. The annual load calculated from regression equations for load compared to flow for the first year after the wildfire was 220 times the annual load for the post-recovery period. To convey the increased frequency and magnitude of average flows in Capulin Canyon after the 1996 Dome wildfire, the stream channel in Capulin Canyon increased in flow capacity by widening and downcutting. As Capulin Canyon peak flows have decreased in both magnitude and frequency with vegetative recovery, the stream channel also has slowly begun to readjust. The channel at the most downstream crest-stage gage, which has the shallowest initial valley slope, is showing the first signs of aggradation.
Comparison of hybrid and baseline ELMy H-mode confinement in JET with the carbon wall
NASA Astrophysics Data System (ADS)
Beurskens, M. N. A.; Frassinetti, L.; Challis, C.; Osborne, T.; Snyder, P. B.; Alper, B.; Angioni, C.; Bourdelle, C.; Buratti, P.; Crisanti, F.; Giovannozzi, E.; Giroud, C.; Groebner, R.; Hobirk, J.; Jenkins, I.; Joffrin, E.; Leyland, M. J.; Lomas, P.; Mantica, P.; McDonald, D.; Nunes, I.; Rimini, F.; Saarelma, S.; Voitsekhovitch, I.; de Vries, P.; Zarzoso, D.; Contributors, JET-EFDA
2013-01-01
The confinement in JET baseline type I ELMy H-mode plasmas is compared to that in so-called hybrid H-modes in a database study of 112 plasmas in JET with the carbon fibre composite (CFC) wall. The baseline plasmas typically have βN ˜ 1.5-2, H98 ˜ 1, whereas the hybrid plasmas have βN ˜ 2.5-3, H98 < 1.5. The database study contains both low- (δ ˜ 0.2-0.25) and high-triangularity (δ ˜ 0.4) hybrid and baseline H-mode plasmas from the last JET operational campaigns in the CFC wall from the period 2008-2009. Based on a detailed confinement study of the global as well as the pedestal and core confinement, there is no evidence that the hybrid and baseline plasmas form separate confinement groups; it emerges that the transition between the two scenarios is of a gradual kind rather than demonstrating a bifurcation in the confinement. The elevated confinement enhancement factor H98 in the hybrid plasmas may possibly be explained by the density dependence in the τ98 scaling as n0.41 and the fact that the hybrid plasmas operate at low plasma density compared to the baseline ELMy H-mode plasmas. A separate regression on the confinement data in this study shows a reduction in the density dependence as n0.09±0.08. Furthermore, inclusion of the plasma toroidal rotation in the confinement regression provides a scaling with the toroidal Alfvén Mach number as Mach_A^{0.41+/- 0.07} and again a reduced density dependence as n0.15±0.08. The differences in pedestal confinement can be explained on the basis of linear MHD stability through a coupling of the total and pedestal poloidal pressure and the pedestal performance can be improved through plasma shaping as well as high β operation. This has been confirmed in a comparison with the EPED1 predictive pedestal code which shows a good agreement between the predicted and measured pedestal pressure within 20-30% for a wide range of βN ˜ 1.5-3.5. The core profiles show a strong degree of pressure profile consistency. No beneficial effect of core density peaking on confinement could be identified for the majority of the plasmas presented here as the density peaking is compensated by a temperature de-peaking resulting in no or only a weak variation in the pressure peaking. The core confinement could only be optimized in case the ions and electrons are decoupled, in which case the ion temperature profile peaking can be enhanced, which benefits confinement. In this study, the latter has only been achieved in the low-triangularity hybrid plasmas, and can be attributed to low-density operation. Plasma rotation has been found to reduce core profile stiffness, and can explain an increase in profile peaking at small radius ρtor = 0.3.
Tardocchi, M; Nocente, M; Proverbio, I; Kiptily, V G; Blanchard, P; Conroy, S; Fontanesi, M; Grosso, G; Kneupner, K; Lerche, E; Murari, A; Cippo, E Perelli; Pietropaolo, A; Syme, B; Van Eester, D; Gorini, G
2011-11-11
The spectral broadening of characteristic γ-ray emission peaks from the reaction (12)C((3)He,pγ)(14)N was measured in D((3)He) plasmas of the JET tokamak with ion cyclotron resonance heating tuned to the fundamental harmonic of (3)He. Intensities and detailed spectral shapes of γ-ray emission peaks were successfully reproduced using a physics model combining the kinetics of the reacting ions with a detailed description of the nuclear reaction differential cross sections for populating the L1-L8 (14)N excitation levels yielding the observed γ-ray emission. The results provide a paradigm, which leverages knowledge from areas of physics outside traditional plasma physics, for the development of nuclear radiation based methods for understanding and controlling fusion burning plasmas.
Two density peaks in low magnetic field helicon plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Y.; Zhao, G.; Ouyang, J. T., E-mail: jtouyang@bit.edu.cn, E-mail: lppmchenqiang@hotmail.com
2015-09-15
In this paper, we report two density peaks in argon helicon plasma under an axial magnetic field from 0 G to 250 G with Boswell-type antenna driven by radio frequency (RF) power of 13.56 MHz. The first peak locates at 40–55 G and the second one at 110–165 G, as the RF power is sustainably increased from 100 W to 250 W at Ar pressure of 0.35 Pa. The absorbed power of two peaks shows a linear relationship with the magnetic field. End views of the discharge taken by intensified charge coupled device reveal that, when the first peak appeared, the discharge luminance moves to the edge ofmore » the tube as the magnetic field increases. For the second peak, the strong discharge area is centered at the two antenna legs after the magnetic field reaches a threshold value. Comparing with the simulation, we suggest that the efficient power absorption of two peaks at which the efficient power absorption mainly appears in the near-antenna region is due to the mode conversion in bounded non-uniform helicon plasma. The two low-field peaks are caused, to some extent, by the excitation of Trivelpiece-Gould wave through non-resonance conversion.« less
Studies of power exhaust and divertor design for a 1.5 GW-level fusion power DEMO
NASA Astrophysics Data System (ADS)
Asakura, N.; Hoshino, K.; Suzuki, S.; Tokunaga, S.; Someya, Y.; Utoh, H.; Kudo, H.; Sakamoto, Y.; Hiwatari, R.; Tobita, K.; Shimizu, K.; Ezato, K.; Seki, Y.; Ohno, N.; Ueda, Y.; Joint Special TeamDEMO Design
2017-12-01
Power exhaust to the divertor and the conceptual design have been investigated for a steady-state DEMO in Japan with 1.5 GW-level fusion power and the major radius of 8.5 m, where the plasma parameters were revised appropriate for the impurity seeding scenario. A system code survey for the Ar impurity seeding suggested the volume-averaged density, impurity concentration and exhaust power from the main plasma of {{P}sep ~ } = 205-285 MW. The divertor plasma simulation (SONIC) was performed in the divertor leg length of 1.6 m with the fixed exhaust power to the edge of {{P}out} = 250 MW and the total radiation fraction at the edge, SOL and divertor ({{P}rad}/{{P}out} = 0.8), as a first step to investigate appropriate design of the divertor size and geometry. At the outer target, partial detachment was produced near the strike-point, and the peak heat load ({{q}target} ) at the attached region was reduced to ~5 MW m-2 with appropriate fuel and impurity puff rates. At the inner divertor target, full detachment of ion flux was produced and the peak {{q}target} was less than 10 MW m-2 mostly due to the surface-recombination. These results showed a power exhaust scenario and the divertor design concept. An integrated design of the water-cooling heat sink for the long leg divertor was proposed. Cu-ally (CuCrZr) cooling pipe was applicable as the heat sink to handle the high heat flux near the strike-point, where displacements per atom rate was estimated to be 0.5-1.5 per year by neutronics calculation. An arrangement of the coolant rooting for Cu-alloy and Reduced Activation Ferritic Martensitic (RAFM) steel (F82H) pipes in a divertor cassette was investigated, and the heat transport analysis of the W-monoblock and Cu-alloy pipe under the peak {{q}target} of 10 MWm-2 and nuclear heating was performed. The maximum temperatures on the W-surface and Cu-alloy pipe were 1021 and 331 °C. Heat flux of 16 MW m-2 was distributed in the major part of the coolant pipe. These results were acceptable for the plasma facing and structural materials.
Observation of low magnetic field density peaks in helicon plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barada, Kshitish K.; Chattopadhyay, P. K.; Ghosh, J.
2013-04-15
Single density peak has been commonly observed in low magnetic field (<100 G) helicon discharges. In this paper, we report the observations of multiple density peaks in low magnetic field (<100 G) helicon discharges produced in the linear helicon plasma device [Barada et al., Rev. Sci. Instrum. 83, 063501 (2012)]. Experiments are carried out using argon gas with m = +1 right helical antenna operating at 13.56 MHz by varying the magnetic field from 0 G to 100 G. The plasma density varies with varying the magnetic field at constant input power and gas pressure and reaches to its peakmore » value at a magnetic field value of {approx}25 G. Another peak of smaller magnitude in density has been observed near 50 G. Measurement of amplitude and phase of the axial component of the wave using magnetic probes for two magnetic field values corresponding to the observed density peaks indicated the existence of radial modes. Measured parallel wave number together with the estimated perpendicular wave number suggests oblique mode propagation of helicon waves along the resonance cone boundary for these magnetic field values. Further, the observations of larger floating potential fluctuations measured with Langmuir probes at those magnetic field values indicate that near resonance cone boundary; these electrostatic fluctuations take energy from helicon wave and dump power to the plasma causing density peaks.« less
Intricate Plasma-Scattered Images and Spectra of Focused Femtosecond Laser Pulses
Ooi, C. H. Raymond; Talib, Md. Ridzuan
2016-01-01
We report on some interesting phenomena in the focusing and scattering of femtosecond laser pulses in free space that provide insights on intense laser plasma interactions. The scattered image in the far field is analyzed and the connection with the observed structure of the plasma at the focus is discussed. We explain the physical mechanisms behind the changes in the colorful and intricate image formed by scattering from the plasma for different compressions, as well as orientations of plano-convex lens. The laser power does not show significant effect on the images. The pulse repetition rate above 500 Hz can affect the image through slow dynamics The spectrum of each color in the image shows oscillatory peaks due to interference of delayed pulse that correlate with the plasma length. Spectral lines of atomic species are identified and new peaks are observed through the white light emitted by the plasma spot. We find that an Ar gas jet can brighten the white light of the plasma spot and produce high resolution spectral peaks. The intricate image is found to be extremely sensitive and this is useful for applications in sensing microscale objects. PMID:27571644
NASA Astrophysics Data System (ADS)
Zhu, W.; Wang, R.
2017-08-01
An alternating current atmospheric pressure plasma jet is generated with noble gas or noble gas/oxygen admixture as working gas. A "core plasma filament" is observed at the center of the dielectric tube and extends to the plasma jet at higher peak-to-peak voltages. This type of plasma jet is believed to be of the same nature with the reported plasma bullet driven by pulsed DC power sources. Double current probes are used to assess the speed of the plasma bullet and show that the speed is around 104-105 m/s. The time dependence of the downstream bullet speed is attributed to the gas heating and in turn the increase of the reduced electric field E/N. Optical emission spectra show the dependence of helium and oxygen emission intensities on the concentration of oxygen additive in the carrier gas, with peak values found at 0.5% O2. Multiple radial jets are realized on dielectric tubes of different sizes. As a case study, one of these multi-jet devices is used to treat B. aureus on the inner surface of a plastic beaker and is shown to be more effective than a single jet.
Ambipolar ion acceleration in an expanding magnetic nozzle
NASA Astrophysics Data System (ADS)
Longmier, Benjamin W.; Bering, Edgar A., III; Carter, Mark D.; Cassady, Leonard D.; Chancery, William J.; Díaz, Franklin R. Chang; Glover, Tim W.; Hershkowitz, Noah; Ilin, Andrew V.; McCaskill, Greg E.; Olsen, Chris S.; Squire, Jared P.
2011-02-01
The helicon plasma stage in the Variable Specific Impulse Magnetoplasma Rocket (VASIMR®) VX-200i device was used to characterize an axial plasma potential profile within an expanding magnetic nozzle region of the laboratory based device. The ion acceleration mechanism is identified as an ambipolar electric field produced by an electron pressure gradient, resulting in a local axial ion speed of Mach 4 downstream of the magnetic nozzle. A 20 eV argon ion kinetic energy was measured in the helicon source, which had a peak magnetic field strength of 0.17 T. The helicon plasma source was operated with 25 mg s-1 argon propellant and 30 kW of RF power. The maximum measured values of plasma density and electron temperature within the exhaust plume were 1 × 1020 m-3 and 9 eV, respectively. The measured plasma density is nearly an order of magnitude larger than previously reported steady-state helicon plasma sources. The exhaust plume also exhibits a 95% to 100% ionization fraction. The size scale and spatial location of the plasma potential structure in the expanding magnetic nozzle region appear to follow the size scale and spatial location of the expanding magnetic field. The thickness of the potential structure was found to be 104 to 105 λDe depending on the local electron temperature in the magnetic nozzle, many orders of magnitude larger than typical laboratory double layer structures. The background plasma density and neutral argon pressure were 1015 m-3 and 2 × 10-5 Torr, respectively, in a 150 m3 vacuum chamber during operation of the helicon plasma source. The agreement between the measured plasma potential and plasma potential that was calculated from an ambipolar ion acceleration analysis over the bulk of the axial distance where the potential drop was located is a strong confirmation of the ambipolar acceleration process.
Observations of strong ion-ion correlations in dense plasmas
Ma, T.; Fletcher, L.; Pak, A.; ...
2014-04-24
Using simultaneous spectrally, angularly, and temporally resolved x-ray scattering, we measure the pronounced ion-ion correlation peak in a strongly coupled plasma. Laser-driven shock-compressed aluminum at ~3× solid density is probed with high-energy photons at 17.9 keV created by molybdenum He-α emission in a laser-driven plasma source. The measured elastic scattering feature shows a well-pronounced correlation peak at a wave vector of k=4Å –1. The magnitude of this correlation peak cannot be described by standard plasma theories employing a linear screened Coulomb potential. Advanced models, including a strong short-range repulsion due to the inner structure of the aluminum ions are howevermore » in good agreement with the scattering data. These studies have demonstrated a new highly accurate diagnostic technique to directly measure the state of compression and the ion-ion correlations. Furthermore, we have since applied this new method in single-shot wave-number resolved S(k) measurements to characterize the physical properties of dense plasmas.« less
A comparative study of carbon plasma emission in methane and argon atmospheres
NASA Astrophysics Data System (ADS)
Yousfi, H.; Abdelli-Messaci, S.; Ouamerali, O.; Dekhira, A.
2018-04-01
The interaction between laser produced plasma (LPP) and an ambient gas is largely investigated by Optical Emission Spectroscopy (OES). The analysis of carbon plasma produced by an excimer KrF laser was performed under controlled atmospheres of methane and argon. For each ambient gas, the features of produced species have been highlighted. Using the time of flight (TOF) analysis, we have observed that the C and C2 exhibit a triple and a double peaks respectively in argon atmosphere in contrast to the methane atmosphere. The evolution of the first peaks of C and C2 follows the plasma expansion, whereas the second peaks move backward, undergoing reflected shocks. It was found that the translational temperature, obtained by Shifted Maxwell Boltzmann distribution function is strongly affected by the nature of ambient gas. The dissociation of CH4 by electronic impact presents the principal approach for explaining the emission of CH radical in reactive plasma. Some chemical reactions have been proposed in order to explain the formation process of molecular species.
A mechanism for plasma waves at the harmonics of the plasma frequency foreshock boundary
NASA Technical Reports Server (NTRS)
Klimas, A. J.
1982-01-01
A bump-on-tail unstable reduced velocity distribution, constructed from data obtained at the upstream boundary of the electron foreshock by the GSFC electron spectrometer experiment on the ISEE-1 satellite, is used as the initial plasma state for a numerical integration of the 1D-Vlasov-Maxwell system of equations. The integration is carried through the growth of the instability, beyond its saturation, and well into the stabilized plasma regime. A power spectrum computed for the electric field of the stabilized plasma is dominated by a narrow peak at the Bohm-Gross frequency of the unstable field mode but also contains significant power at the harmonics of the Bohm-Gross frequency. The harmonic power is in sharp peaks which are split into closely spaced doublets. The fundamental peak at the Bohm-Gross frequency is split into a closely spaced triplet. The mechanism for excitation of the second harmonic is shown to be second order wave-wave coupling.
Reznik, Y; Dehennin, L; Coffin, C; Mahoudeau, J; Leymarie, P
2001-01-01
19-Nortestosterone (nandrolone) is an anabolic steroid compound widely used as a doping agent by athletes. The analysis of its urinary metabolites, 19-norandrosterone (NA) and 19-noretiocholanolone (NE) glucuronides, allows the detection of surreptitious administration of nandrolone in sport. A threshold concentration at 2 microgram/L urinary nandrolone metabolites is advocated by the International Olympic Committee for the detection of doping, but some controversy concerning the validity of this threshold arose from the demonstration of endogenous production of nandrolone in mammals, including humans. The regulation of human nandrolone production and its contribution in vivo to the process of aromatization remain unknown. In the present study 10 healthy men were successively submitted to insulinic stress and gonadal stimulation by hCG administration. Urinary NA and NE concentrations were quantified by gas chromatography-mass spectrometry. NA was detected in basal urine samples from all subjects, with a mean urinary excretion rate (UER) of 3.17 +/- 0.35 ng/h, whereas NE was detected in 4 of 10 (UER range, 0.8-4.7 ng/h). Insulinic hypoglycemia did not significantly modify mean NA UER despite random intraindividual variations between timed urine collections. After hCG administration, NA UER increased by 250% (P < 0.01) and estradiol (E(2)) UER by 260% (P < 0.001). The maximum NA concentration obtained after stimulation was 0.43 microgram/L. NA UER, plasma E(2), and E(2)/T ratio peaked on day 1 after hCG administration, whereas plasma T peaked later on day 3. NA UER correlated with plasma E(2) (r = 0.61; P < 0.001) and E(2)/T (r = 0.51; P < 0.001), but not with plasma T. In conclusion, insulinic stress did not significantly alter nandrolone metabolism, whereas the effect of hCG was a stimulation of NA excretion in all subjects, which constitutes strong support for the endogenous origin of low basal NA excretion. The comparative kinetics of NA UER, plasma E(2), and E(2)/T ratio suggest a contribution of the aromatase process to nandrolone biosynthesis in man.
Nicotine Delivery and Vaping Behavior During ad Libitum E-cigarette Access
St.Helen, Gideon; Ross, Kathryn C.; Dempsey, Delia A.; Havel, Christopher M.; Jacob, Peyton; Benowitz, Neal L.
2017-01-01
Objective To characterize vaping behavior and nicotine intake during ad libitum e-cigarette access. Methods Thirteen adult e-cigarette users had 90 minutes of videotaped ad libitum access to their usual e-cigarette. Plasma nicotine was measured before and every 15 minutes after the first puff; subjective effects were measured before and after the session. Results Average puff duration and interpuff interval were 3.5±1.4 seconds (±SD) and 118±141 seconds, respectively. 12% of puffs were unclustered puffs while 43%, 28%, and 17% were clustered in groups of 2–5, 6–10, and >10 puffs, respectively. On average, 4.0±3.3 mg of nicotine was inhaled; the maximum plasma nicotine concentration (Cmax) was 12.8±8.5 ng/mL. Among the 8 tank users, number of puffs was positively correlated with amount of nicotine inhaled, Cmax, and area under the plasma nicotine concentration-time curve (AUC0→90min) while interpuff interval was negatively correlated with Cmax and AUC0→90. Conclusion Vaping patterns differ from cigarette smoking. Plasma nicotine levels were consistent with intermittent dosing of nicotine from e-cigarettes compared to the more bolus dosing from cigarettes. Differences in delivery patterns and peak levels of nicotine achieved could influence the addictiveness of e-cigarettes compared to conventional cigarettes. PMID:28393086
Active Control of Power Exhaust in Strongly Heated ASDEX Upgrade Plasmas
NASA Astrophysics Data System (ADS)
Dux, Ralph; Kallenbach, Arne; Bernert, Matthias; Eich, Thomas; Fuchs, Christoph; Giannone, Louis; Herrmann, Albrecht; Schweinzer, Josef; Treutterer, Wolfgang
2012-10-01
Due to the absence of carbon as an intrinsic low-Z radiator, and tight limits for the acceptable power load on the divertor target, ITER will rely on impurity seeding for radiative power dissipation and for generation of partial detachment. The injection of more than one radiating species is required to optimise the power removal in the main plasma and in the divertor region, i.e. a low-Z species for radiation in the divertor and a medium-Z species for radiation in the outer core plasma. In ASDEX Upgrade, a set of robust sensors, which is suitable to feedback control the radiated power in the main chamber and the divertor as well as the electron temperature at the target, has been developed. Different feedback schemes were applied in H-mode discharges with a maximum heating power of up to 23,W, i.e. at ITER values of P/R (power per major radius) to control all combinations of power flux into the divertor region, power flux onto the target or electron temperature at the target through injection of nitrogen as the divertor radiator and argon as the main chamber radiator. Even at the highest heating powers the peak heat flux density at the target is kept at benign values. The control schemes and the plasma behaviour in these discharges will be discussed.
Moody, J.A.; Martin, D.A.
2001-01-01
Wildfire alters the hydrologic response of watersheds, including the peak discharges resulting from subsequent rainfall. Improving predictions of the magnitude of flooding that follows wildfire is needed because of the increase in human population at risk in the wildland-urban interface. Because this wildland-urban interface is typically in mountainous terrain, we investigated rainfall-runoff relations by measuring the maximum 30 min rainfall intensity and the unit-area peak discharge (peak discharge divided by the area burned) in three mountainous watersheds (17-26.8 km2) after a wildfire. We found rainfall-runoff relations that relate the unit-area peak discharges to the maximum 30 min rainfall intensities by a power law. These rainfall-runoff relations appear to have a threshold value for the maximum 30 min rainfall intensity (around 10 mm h-1) such that, above this threshold, the magnitude of the flood peaks increases more rapidly with increases in intensity. This rainfall intensity could be used to set threshold limits in rain gauges that are part of an early-warning flood system after wildfire. The maximum unit-area peak discharges from these three burned watersheds ranged from 3.2 to 50 m3 s-1 km-2. These values could provide initial estimates of the upper limits of runoff that can be used to predict floods after wildfires in mountainous terrain. Published in 2001 by John Wiley and Sons, Ltd.
Parametric study of plasma-mediated thermoluminescence produced by Al2O3 sub-micron powders
NASA Astrophysics Data System (ADS)
Morávek, T.; Ambrico, P. F.; Ambrico, M.; Schiavulli, L.; Ráheľ, J.
2017-10-01
Sub-micron Al2O3 powders with a surface activated by dielectric barrier discharge exhibit improved performance in wet deposition of ceramic layers. In addressing the possible mechanisms responsible for the observed improvement, a comprehensive thermoluminescence (TL) study of plasma-activated powders was performed. TL offers the unique possibility of exploring the population of intrinsic electrons/holes in the charge trapping states. This study covers a wide range of experimental conditions affecting the TL of powders: treatment time, plasma working gas composition, change of discharge configuration, step-annealing of powder, exposure to laser irradiation and aging time. Deconvoluted TL spectra were followed for the changes in their relative contributions. The TL spectra of all tested gases (air, Ar, N2 and 5% He in N2) consist of the well-known main dosimetric peak at 450 K and a peak of similar magnitude at higher temperatures, centered between 700 and 800 K depending on the working gas used. N2 plasma treatment gave rise to a new specific TL peak at 510 K, which exhibited several peculiarities. Initial thermal annealing of Al2O3 powders led to its significant amplification (unlike the other peaks); the peak was insensitive to optical bleaching, and it exhibited slow gradual growth during the long-term aging test. Besides its relevance to the ceramic processing studies, a comprehensive set of data is presented that provides a useful and unconventional view on plasma-mediated material changes.
Ye, Ping-xian; Ye, Ping-zhen; Zhu, Jian-hua; Chen, Wei; Gao, Dan-chen
2014-05-01
To investigate the effect of atorvastatin on exercise tolerance in patients with diastolic dysfunction and exercise-induced hypertension. A randomized, double-blind, placebo-controlled prospective study was performed. Sixty patients with diastolic dysfunction (mitral flow velocity E/A <1) and exercise-induced hypertension (SBP>200 mm Hg) treated with atorvastatin (20 mg q.d) or placebo for 1 year. Cardiopulmonary exercise test and exercise blood pressure measurement were performed. Plasma B-natriuretic peptide (BNP) concentration at rest and at peak exercise, plasma high sensitive-C reaction protein (hs-CRP) and endothelin (ET) concentration were determined at baseline and after treatment. After treatment by atorvastatin, the resting SBP, pulse pressure, the peak exercise SBP and BNP were significantly decreased; and the exercise time, metabolic equivalent, maximal oxygen uptake and anaerobic threshold were increased. All of these parameters had significant differences with baseline levels (P<0.05) and the rest pulse pressure, the peak exercise SBP and BNP, and the exercise time had significant differences compared with placebo treatment (P<0.05). Plasma concentrations of hs-CRP and ET were markedly reduced by atorvastatin treatment compared with baseline and placebo (P<0.05). No difference in above parameters was found before and after placebo treatment (P>0.05). In patients with diastolic dysfunction at rest and exercise-induced hypertension, atorvastatin can effectively reduce plasma hs-CRP and ET level, lower blood pressure and peak exercise SBP, decrease peak exercise plasma BNP concentration, and ultimately improve exercise tolerance.
III-N light emitting diodes fabricated using RF nitrogen gas source MBE
NASA Astrophysics Data System (ADS)
Van Hove, J. M.; Carpenter, G.; Nelson, E.; Wowchak, A.; Chow, P. P.
1996-07-01
Homo- and heterojunction III-N light emitting diodes using RF atomic nitrogen plasma molecular beam epitaxy have been grown. GaN films deposited on sapphire using this growth technique exhibited an extremely sharp X-ray diffraction with a full width half maximum of 112 arc sec. p-type doping of the nitride films was done with elemental Mg and resulted in as-grown p-type material with resistivities as low as 2 Ω · cm. Both homo- and heterojunction LEDs showed clear rectification. Emission from the GaN homojunction deposited on n-type SiC was peaked at 410 nm while the AlGaNGaN(Zn)AlGaN double heterojunction LEDs emission was centered about 520 nm.
Plasma fluctuations in a Kaufman thruster
NASA Technical Reports Server (NTRS)
Serafini, J. S.; Terdan, F. F.
1973-01-01
Measurements of the RMS magnitude, spectra, and cross correlations for the fluctuations in the beam, discharge, and neutralizer keeper currents are presented for a 30 cm diameter dished grid ion thruster for a range of magnetic baffle currents. The ratio of RMS to mean ion beam current varied from 0.04 to 0.23. The spectra of the amplitudes of the beam and discharge current fluctuations were taken up to 9 MHz and show that the predominant amplitudes occur at frequencies of 10 kHz or below. The falloff with increasing frequency is rapid. Frequencies above 100 kHz the spectral levels are 45 kb or more below the maximum peak amplitudes. The cross correlations revealed the ion beam fluctuations to have large radial and axial scales.
Jin, Ya; Manabe, Takashi
2005-07-01
A method to analyze human plasma proteins without fractionation, directly applying a plasma-matrix mixture on the target plate of a matrix-assisted laser desorption/ionization-time of flight-mass spectrometer (MALDI-TOF-MS), has been described. Peaks of ionized plasma proteins could not be detected applying a mixture of an undiluted plasma sample and a matrix solution, but they appeared when the plasma was diluted before mixing with the matrix. Tenfold diluted plasma provided well-resolved protein peaks in the m/z range from 4000 to 30,000. The addition of a simple post-crystallization washing procedure performed on the target plate further improved the quality of mass spectra. We numbered 58 peaks in the range of 4-160 kDa and 32 out of which were assigned to the plasma protein species which have been reported. Especially high sensitivity and resolution were obtained in the region < 30 kDa, where multiple isoforms of apolipoprotein A-I, apolipoprotein A-II, apolipoprotein C-I, apolipoprotein C-II, apolipoprotein C-III, and transthyretin could be assigned. Various post-translational modifications are involved in the isoforms, e.g., proteolytic cleavage, glycosylation and chemical modifications. This method will become complementary with the present electrophoretic techniques, especially for the analysis of low-molecular-mass proteins.
Modeled future peak streamflows in four coastal Maine rivers
Hodgkins, Glenn A.; Dudley, Robert W.
2013-01-01
To safely and economically design bridges and culverts, it is necessary to compute the magnitude of peak streamflows that have specified annual exceedance probabilities (AEPs). Annual precipitation and air temperature in the northeastern United States are, in general, projected to increase during the 21st century. It is therefore important for engineers and resource managers to understand how peak flows may change in the future. This report, prepared in cooperation with the Maine Department of Transportation (MaineDOT), presents modeled changes in peak flows at four basins in coastal Maine on the basis of projected changes in air temperature and precipitation. To estimate future peak streamflows at the four basins in this study, historical values for climate (temperature and precipitation) in the basins were adjusted by different amounts and input to a hydrologic model of each study basin. To encompass the projected changes in climate in coastal Maine by the end of the 21st century, air temperatures were adjusted by four different amounts, from -3.6 degrees Fahrenheit (ºF) (-2 degrees Celsius (ºC)) to +10.8 ºF (+6 ºC) of observed temperatures. Precipitation was adjusted by three different percentage values from -15 percent to +30 percent of observed precipitation. The resulting 20 combinations of temperature and precipitation changes (includes the no-change scenarios) were input to Precipitation-Runoff Modeling System (PRMS) watershed models, and annual daily maximum peak flows were calculated for each combination. Modeled peak flows from the adjusted changes in temperature and precipitation were compared to unadjusted (historical) modeled peak flows. Annual daily maximum peak flows increase or decrease, depending on whether temperature or precipitation is adjusted; increases in air temperature (with no change in precipitation) lead to decreases in peak flows, whereas increases in precipitation (with no change in temperature) lead to increases in peak flows. As the magnitude of air temperatures increase in the four basins, peak flows decrease by larger amounts. If precipitation is held constant (no change from historical values), 17 to 26 percent decreases in peak flow occur at the four basins when temperature is increased by 7.2°F. If temperature is held constant, 26 to 38 percent increases in peak flow result from a 15-percent increase in precipitation. The largest decreases in peak flows at the four basins result from 15-percent decreases in precipitation combined with temperature increases of 10.8°F. The largest increases in peak flows generally result from 30-percent increases in precipitation combined with 3.6 °F decreases in temperatures. In many cases when temperature and precipitation both increase, small increases or decreases in annual daily maximum peak flows result. For likely changes projected for the northeastern United States for the middle of the 21st century (temperature increase of 3.6 °F and precipitation increases of 0 to 15 percent), peak-flow changes at the four coastal Maine basins in this study are modeled to be evenly distributed between increases and decreases of less than 25 percent. Peak flows with 50-percent and 1-percent AEPs (equivalent to 2-year and 100-year recurrence interval peak flows, respectively) were calculated for the four basins in the study using the PRMS-modeled annual daily maximum peak flows. Modeled peak flows with 50-percent and 1-percent AEPs with adjusted temperatures and precipitation were compared to unadjusted (historical) modeled values. Changes in peak flows with 50-percent AEPs are similar to changes in annual daily maximum peak flow; changes in peak flows with 1-percent AEPs are similar in pattern to changes in annual daily maximum peak flow, but some of the changes associated with increasing precipitation are much larger than changes in annual daily maximum peak flow. Substantial decreases in maximum annual winter snowpack water equivalent are modeled to occur with increasing air temperatures at the four basins in the study. (Snowpack is the snow on the ground that accumulates during a winter, and water equivalent is the amount of water in a snowpack if it were melted.) The decrease in modeled peak flows with increasing air temperature, given no change in precipitation amount, is likely caused by these decreases in winter snowpack and resulting decreases in snowmelt runoff. This Scientific Investigations Report, prepared in cooperation with the Maine Department of Transportation, presents a summary of modeled changes in peak flows at four basins in coastal Maine on the basis of projected changes in air temperature and precipitation. The full Fact Sheet (Hodgkins and Dudley, 2013) is available at http://pubs.usgs.gov/fs/2013/3021/.
Characterization of Low Pressure Cold Plasma in the Cleaning of Contaminated Surfaces
NASA Technical Reports Server (NTRS)
Lanz, Devin Garrett; Hintze, Paul E.
2016-01-01
The characterization of low pressure cold plasma is a broad topic which would benefit many different applications involving such plasma. The characterization described in this paper focuses on cold plasma used as a medium in cleaning and disinfection applications. Optical Emission Spectroscopy (OES) and Mass Spectrometry (MS) are the two analytical methods used in this paper to characterize the plasma. OES analyzes molecules in the plasma phase by displaying the light emitted by the plasma molecules on a graph of wavelength vs. intensity. OES was most useful in identifying species which may interact with other molecules in the plasma, such as atomic oxygen or hydroxide radicals. Extracting useful data from the MS is done by filtering out the peaks generated by expected molecules and looking for peaks caused by foreign ones leaving the plasma chamber. This paper describes the efforts at setting up and testing these methods in order to accurately and effectively characterize the plasma.
NASA Astrophysics Data System (ADS)
Ying, Minju; Wang, XiaoXiao; Cheng, Wei; Liao, Bin; Zhang, Xu
2015-06-01
Optical emission spectra of the plasma produced by 1.06-μm Nd:YAG laser irradiation of a potassium titanyl phosphate (KTP) crystal were recorded and analyzed in a time- and spatially resolved manner. The composition and evolution of the plasma plume were studied in low vacuum conditions. Emission lines associated with Ti(I), Ti(II) and K(I) were identified in the plasma. The delay times of emission peaks for the ablated species were investigated as a function of the observation distance from the target surface, and the velocities of these species were derived accordingly. Two emission peaks corresponding to a fast and a slow component of ablated Ti(I) were observed by optical time-of-flight spectroscopy. The origins of the two peaks and a possible mechanism for the laser ablation are discussed.
Lack of effect of lacosamide on the pharmacokinetic and pharmacodynamic profiles of warfarin.
Stockis, Armel; van Lier, Jan Jaap; Cawello, Willi; Kumke, Thomas; Eckhardt, Klaus
2013-07-01
The aim of this study was to evaluate the effect of the antiepileptic drug lacosamide on the pharmacokinetics and pharmacodynamics of the anticoagulant warfarin. In this open-label, two-treatment crossover study, 16 healthy adult male volunteers were randomized to receive a single 25-mg dose of warfarin alone in one period and lacosamide 200 mg twice daily on days 1-9 with a single 25 mg dose of warfarin coadministered on day 3 in the other period. There was a 2-week washout between treatments. Pharmacokinetic end points were area under the plasma concentration-time curve (AUC(0,last) and AUC(0,∞) ) and maximum plasma concentration (Cmax ) for S- and R-warfarin. Pharmacodynamic end points were area under the international normalized ratio (INR)-time curve (AUCINR ), maximum INR (INRmax ), maximum prothrombin time (PTmax ) and area under the PT-time curve (AUCPT ). Following warfarin and lacosamide coadministration, Cmax and AUC of S- and R-warfarin, as well as peak value and AUC of PT and INR, were equivalent to those after warfarin alone. In particular, the AUC(0,∞) ratio (90% confidence interval) for coadministration of warfarin and lacosamide versus warfarin alone was 0.97 (0.94-1.00) for S-warfarin and 1.05 (1.02-1.09) for R-warfarin, and the AUCINR ratio was 1.04 (1.01-1.06). All participants completed the study. Coadministration of lacosamide 400 mg/day did not alter the pharmacokinetics of warfarin 25 mg or the anticoagulation level. These results suggest that there is no need for dose adjustment of warfarin when coadministered with lacosamide. Wiley Periodicals, Inc. © 2013 International League Against Epilepsy.
NASA Astrophysics Data System (ADS)
Gonor, Alexander; Hooton, Irene
2006-07-01
Impact of a rigid projectile (impactor), against a metal target and a condensed explosive surface considered as the important process accompanying the normal entry of a rigid projectile into a target, was overlooked in the preceding studies. Within the framework of accurate shock wave theory, the flow-field, behind the shock wave attached to the perimeter of the adjoined surface, was defined. An important result is the peak pressure rises at points along the target surface away from the stagnation point. The maximum values of the peak pressure are 2.2 to 3.2 times higher for the metallic and soft targets (nitromethane, PBX 9502), than peak pressure values at the stagnation point. This effect changes the commonly held notion that the maximum peak pressure is reached at the projectile stagnation point. In the present study the interaction of a spherical decaying blast wave, caused by an underwater explosion, with a piece-wise plane target, having corner configurations, is investigated. The numerical calculation results in the determination of the vulnerable spots on the target, where the maximum peak overpressure surpassed that for the head-on shock wave reflection by a factor of 4.
Chen, Xiuhua; Li, Shan; Huo, Xuezhen; Fu, Xiuxiu; Dong, Xiaonan
2015-01-01
Background Coronary slow flow (CSF) is a special coronary microvascular disorder. The pathogenesis and effective therapeutics of CSF remain unclear. This study aimed to evaluate the global and regional functions of the left ventricle (LV) and investigate the efficacy of nicorandil in patients with CSF. Patients and methods Thirty-six patients with CSF in the left anterior descending (LAD) branch and 20 patients with normal coronary arteries were included. Global and regional functions of the LV supplied by LAD were measured using conventional Doppler echocardiography and two-dimensional speckle tracking echocardiography, respectively, within 24 h after coronary angiography. Concentrations of plasma nitric oxide (NO) and endothelin-1 (ET-1) were detected using colorimetry and radioimmunoassay, respectively. The function of the LV and the levels of NO and ET-1 were also investigated before and 90 days after treatment with 15 mg/day of nicorandil. Results Compared with the control group, the early diastolic peak velocity (E), E/A ratio, and plasma NO levels were lower, whereas the late diastolic peak flow velocity (A) and plasma ET-1 levels were significantly higher in the CSF group (P<0.05). The longitudinal strain rate peak of the LV was reduced significantly in CSF patients (P<0.001). After treatment, 75% (27/36) of CSF patients were free of chest pain. The values of E peak, E/A ratio, longitudinal strain rate peak, and plasma NO level were increased (P<0.001), whereas the ET-1 level was decreased in CSF patients (P<0.001). Conclusion Nicorandil may improve chest pain symptoms and the impaired function of the LV, possibly by increasing plasma NO and reducing ET-1 in CSF. PMID:25325437
Frost, Charles; Song, Yan; Barrett, Yu Chen; Wang, Jessie; Pursley, Janice; Boyd, Rebecca A; LaCreta, Frank
2014-01-01
Background Currently, there are no direct comparisons of apixaban and rivaroxaban, two new oral direct factor Xa inhibitors approved for management of thromboembolic disorders. Objective Compare the pharmacokinetics and anti-factor Xa activity (AXA) of apixaban and rivaroxaban. Methods In this randomized, open-label, two-period, two-treatment crossover study, healthy subjects (N=14) received apixaban 2.5 mg twice daily (BID) and rivaroxaban 10 mg once daily (QD) for 4 days with a ≥4.5-day washout. Plasma samples were obtained for pharmacokinetic and AXA assessments; parameters were calculated using noncompartmental methods. Results Median time-to-maximum concentration was 2 hours for both compounds, and the mean half-life was 8.7 and 7.9 hours for apixaban and rivaroxaban, respectively. Daily exposure, the area under the curve (AUC(0–24)), appeared similar for rivaroxaban (1,094 ng · h/mL) and apixaban (935 ng · h/mL), whereas mean peak-to-trough plasma concentration ratio was 3.6-fold greater for rivaroxaban (16.9) than apixaban (4.7). Coefficient of variation for exposure parameters (AUC0–24, Cmax, Cmin) was 20%–24% for apixaban versus 29%–46% for rivaroxaban. Peak AXA, AXA AUC(0–24), and AXA fluctuation were ~2.5-, 1.3-, and 3.5-fold higher for rivaroxaban than apixaban, respectively. Trough concentrations and AXA were lower for rivaroxaban (10 ng/mL and 0.17 IU/mL vs 17 ng/mL and 0.24 IU/mL for apixaban, respectively). Rivaroxaban exhibited a steeper concentration–AXA response (slope: 0.0172 IU/ng vs 0.0134 IU/ng for apixaban, P<0.0001). Conclusion Apixaban 2.5 mg BID demonstrated less intersubject variability in exposure, lower AXA AUC, and higher trough and smaller peak-to-trough fluctuations in plasma concentration and AXA, suggesting more constant anticoagulation compared with rivaroxaban 10 mg QD. However, the clinical impact of these differences on the relative efficacy and safety of apixaban and rivaroxaban remains to be determined. PMID:25419161
Flood frequency analysis for nonstationary annual peak records in an urban drainage basin
Villarini, G.; Smith, J.A.; Serinaldi, F.; Bales, J.; Bates, P.D.; Krajewski, W.F.
2009-01-01
Flood frequency analysis in urban watersheds is complicated by nonstationarities of annual peak records associated with land use change and evolving urban stormwater infrastructure. In this study, a framework for flood frequency analysis is developed based on the Generalized Additive Models for Location, Scale and Shape parameters (GAMLSS), a tool for modeling time series under nonstationary conditions. GAMLSS is applied to annual maximum peak discharge records for Little Sugar Creek, a highly urbanized watershed which drains the urban core of Charlotte, North Carolina. It is shown that GAMLSS is able to describe the variability in the mean and variance of the annual maximum peak discharge by modeling the parameters of the selected parametric distribution as a smooth function of time via cubic splines. Flood frequency analyses for Little Sugar Creek (at a drainage area of 110 km2) show that the maximum flow with a 0.01-annual probability (corresponding to 100-year flood peak under stationary conditions) over the 83-year record has ranged from a minimum unit discharge of 2.1 m3 s- 1 km- 2 to a maximum of 5.1 m3 s- 1 km- 2. An alternative characterization can be made by examining the estimated return interval of the peak discharge that would have an annual exceedance probability of 0.01 under the assumption of stationarity (3.2 m3 s- 1 km- 2). Under nonstationary conditions, alternative definitions of return period should be adapted. Under the GAMLSS model, the return interval of an annual peak discharge of 3.2 m3 s- 1 km- 2 ranges from a maximum value of more than 5000 years in 1957 to a minimum value of almost 8 years for the present time (2007). The GAMLSS framework is also used to examine the links between population trends and flood frequency, as well as trends in annual maximum rainfall. These analyses are used to examine evolving flood frequency over future decades. ?? 2009 Elsevier Ltd.
Optical plasma monitoring of Y-Ba-Cu-O rf sputter target transients
NASA Astrophysics Data System (ADS)
Klein, J. D.; Yen, A.
1989-12-01
The plasma emission spectra resulting from rf sputtering Y-Ba-Cu-O targets were observed as a function of sputter time. Although most lines of the observed spectra are not attributable to target species, peaks associated with each of the cation elements were resolved. The Ba and Cu peaks can be used as tracking indicators of process conditions. For example, switching from an O2/Ar sputter atmosphere to pure Ar enhanced the Ba peak much more than that associated with Cu. The emission spectra from a newly fabricated target exhibited a slow first-order transient response in seeking equilibrium with the rf plasma. The transient response of a previously sputtered target is also first order but has a much shorter time constant.
Gorden, P J; Kleinhenz, M D; Wulf, L W; KuKanich, B; Lee, C J; Wang, C; Coetzee, J F
2016-01-01
Mastitis is a frequent problem among dairy cows, reducing milk yield and increasing cull rates. Systemic therapy with the cephalosporin antimicrobial ceftiofur hydrochloride (CEF) may improve therapeutic outcomes, but the incidence of CEF violative residues has increased annually since 2011. One potential explanation is that disease status may alter the pharmacokinetics (PK) of CEF. To test this hypothesis, we compared the plasma PK of CEF in healthy cows with those with severe endotoxic mastitis. Eight cows with naturally occurring mastitis and 8 clinically healthy cows were treated with 2.2 mg of CEF per kilogram of body weight once daily for 5d via the intramuscular route. Blood was collected at 0, 0.33, 0.67, 1, 1.5, 2, 3, 4, 8, 16, and 24h after the first CEF administration and every 8h thereafter until 120 h after the final dose. Plasma samples were analyzed for CEF concentrations using liquid chromatography coupled with mass spectrometry. With the exception of time 0, CEF was detected at all time points. The disease group had a significantly higher plasma CEF concentration at t=3h after the first injection and a significantly lower plasma concentration from 40 to 152 h following the first injection, with the exception of the t=64 h time point. Data following the first injection (time 0-24 h) were fit to a single-dose, noncompartmental PK model. This model indicated that the disease group had a shorter plasma half-life. A multidose, noncompartmental model was used to determine steady-state PK. Compared with control cows, the disease group had an initially higher peak concentration and a higher volume of distribution and drug clearance rates. The disease group also had a lower area under the curve per dosing interval, steady-state concentration maximum, and dose-adjusted peak steady-state concentration. All other PK parameters were not different between the 2 groups. Altered PK, as suggested by this trial, may contribute to an increased risk for the development of a violative residue in meat. Further research is needed to more completely characterize drug distribution in diseased cattle and to study the effect of coadministration of other drugs on drug distribution. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Placental transfer and pharmacokinetics of a single oral dose of [14C]p-nitrophenol in rats.
Abu-Qare, A W; Brownie, C F; Abou-Donia, M B
2000-09-01
The pharmacokinetics and placental transfer of a single oral dose of 100 mg/kg (10 microCi/kg, 16% of acute oral LD50) of uniformly phenyl-labeled [14C]p-nitrophenol were investigated in pregnant Sprague-Dawley rats at 14-18 days of gestation. Three animals were killed on gestation day 18, at 0.5, 1, 2, 4, 12, 24, and 48 h after dosing. Radioactivity was rapidly absorbed and distributed throughout the maternal and fetal tissues. The gastrointestinal tract contents retained 20% and 2% of the dose at 0.5 h and 4 h after dosing. The peak maternal plasma concentration of radioactivity (microg p-nitrophenol equivalent/ml) was 7.17 compared with 0.37 for fetal plasma at 0.5 h. Maximum concentration of radioactivity (microg p-nitrophenol equivalent/g fresh tissue) was detected in most tissues 0.5 h after dosing and was in descending order: kidney 23.27, liver 12.37, placenta 3.56, fetus 2.17, and brain 1.99. Radioactivity was eliminated from plasma and all tissues beiexponentially. The half-lives of elimination of 14C were 34.65 h and 69.30 h for maternal and fetal plasma, respectively. p-Nitrophenol, detected by HPLC, was the major compound identified in plasma and tissues. While p-nitrophenol disappeared biphasically from maternal plasma and kidney, it was eliminated monophasically from brain, placenta, and liver. p-Nitrocatechol and p-aminophenol were detected in the liver with peak concentrations at 0.5 h of 1.13 and 1.00 microg/g fresh tissue, respectively. While the change in the concentration of p-nitrocatechol with time was monophasic, that of p-aminophenol showed a biphasic pattern with elimination half-lives of 1.93 h and 4.95 h, respectively. Radioactivity was rapidly excreted in the urine mostly as polar metabolites, while only 3% of the dose was recovered in the feces. Radioactive materials excreted in the urine comprised: glucuronides 4%, sulfates 8%, hot-acid hydrolysates 11%, nonconjugated compounds 16%, and water-soluble metabolites 61%. This study demonstrated that although orally administered p-nitrophenol is a rapidly absorbed and excreted compound, it is transported to the maternal brain and the fetus and may pose a health risk following exposure to toxic doses during pregnancy.
Etching in Chlorine Discharges Using an Integrated Feature Evolution-Plasma Model
NASA Technical Reports Server (NTRS)
Hwang, Helen H.; Bose, Deepak; Govindan, T. R.; Meyyappan, M.; Biegel, Bryan (Technical Monitor)
2001-01-01
Etching of semiconductor materials is reliant on plasma properties. Quantities such as ion and neutral fluxes, both in magnitude and in direction, are often determined by reactor geometry (height, radius, position of the coils, etc.) In order to obtain accurate etching profiles, one must also model the plasma as a whole to obtain local fluxes and distributions. We have developed a set of three models that simulates C12 plasmas for etching of silicon, ion and neutral trajectories in the plasma, and feature profile evolution. We have found that the location of the peak in the ion densities in the reactor plays a major role in determining etching uniformity across the wafer. For a stove top coil inductively coupled plasma (ICP), the ion density is peaked at the top of the reactor. This leads to nearly uniform neutral and ion fluxes across the wafer. A side coil configuration causes the ion density to peak near the sidewalls. Ion fluxes are thus greater toward the wall's and decrease toward the center. In addition, the ions bombard the wafer at a slight angle. This angle is sufficient to cause slanted profiles, which is highly undesirable.
NASA Astrophysics Data System (ADS)
Yan, Xingting; Zhu, Ping; Sun, Youwen
2016-10-01
The characteristic profile and magnitude are predicted in theory for the neoclassical toroidal viscosity (NTV) torque induced by the plasma response to the resonant magnetic perturbation (RMP) in a tokamak with an edge pedestal, using the newly developed module coupling the NIMROD and the NTVTOK codes. For a low β equilibrium, the NTV torque is mainly induced by the dominant toroidal mode of plasma response. The NTV torque profile is radially localized and peaked, which is determined by profiles of both the equilibrium temperature and the plasma response fields. In general, the peak of NTV torque profile is found to trace the pedestal location. The magnitude of NTV torque is extremely sensitive to the β of pedestal top; for a given plasma response, the peak value of NTV torque can increase by three orders of magnitude, when the pedestal β increases by only one order of magnitude. This suggests a more significant role of NTV torque in higher plasma β regimes. Supported by the National Magnetic Confinement Fusion Program of China under Grant Nos. 2014GB124002 and 2015GB101004, and the 100 Talent Program of the Chinese Academy of Sciences.
Probing a dusty magnetized plasma with self-excited dust-density waves
NASA Astrophysics Data System (ADS)
Tadsen, Benjamin; Greiner, Franko; Piel, Alexander
2018-03-01
A cloud of nanodust particles is created in a reactive argon-acetylene plasma. It is then transformed into a dusty magnetized argon plasma. Plasma parameters are obtained with the dust-density wave diagnostic introduced by Tadsen et al. [Phys. Plasmas 22, 113701 (2015), 10.1063/1.4934927]. A change from an open to a cylindrically enclosed nanodust cloud, which was observed earlier, can now be explained by a stronger electric confinement if a vertical magnetic field is present. Using two-dimensional extinction measurements and the inverse Abel transform to determine the dust density, a redistribution of the dust with increasing magnetic induction is found. The dust-density profile changes from being peaked around the central void to being peaked at an outer torus ring resulting in a hollow profile. As the plasma parameters cannot explain this behavior, we propose a rotation of the nanodust cloud in the magnetized plasma as the origin of the modified profile.
NASA Astrophysics Data System (ADS)
Zhu, JianGuo; Chen, Wei; Xie, HuiMin
2015-03-01
Thermal barrier coating (TBC) systems are widely used in industrial gas-turbine engines. However, premature failures have impaired the use of TBCs and cut down their lifetime, which requires a better understanding of their failure mechanisms. In the present study, experimental studies of isothermal cycling are firstly carried out with the observation and estimation of microstructures. According to the experimental results, a finite element model is established for the analysis of stress perpendicular to the TBC/BC interface. Detailed residual stress distributions in TBC are obtained to reflect the influence of mechanical properties, oxidation, and interfacial roughness. The calculated results show that the maximum tensile stress concentration appears at the peak of TBC and continues to increase with thermal cycles. Because of the microstructural characteristics of plasma-sprayed TBCs, cracks initialize in tensile stress concentration (TSC) regions at the peaks of TBC and propagate along the TBC/BC interface resulting in the spallation of TBC. Also, the inclusion of creep is crucial to failure prediction and is more important than the inclusion of sintering in the simulation.
Sleep spindle alterations in patients with Parkinson's disease
Christensen, Julie A. E.; Nikolic, Miki; Warby, Simon C.; Koch, Henriette; Zoetmulder, Marielle; Frandsen, Rune; Moghadam, Keivan K.; Sorensen, Helge B. D.; Mignot, Emmanuel; Jennum, Poul J.
2015-01-01
The aim of this study was to identify changes of sleep spindles (SS) in the EEG of patients with Parkinson's disease (PD). Five sleep experts manually identified SS at a central scalp location (C3-A2) in 15 PD and 15 age- and sex-matched control subjects. Each SS was given a confidence score, and by using a group consensus rule, 901 SS were identified and characterized by their (1) duration, (2) oscillation frequency, (3) maximum peak-to-peak amplitude, (4) percent-to-peak amplitude, and (5) density. Between-group comparisons were made for all SS characteristics computed, and significant changes for PD patients vs. control subjects were found for duration, oscillation frequency, maximum peak-to-peak amplitude and density. Specifically, SS density was lower, duration was longer, oscillation frequency slower and maximum peak-to-peak amplitude higher in patients vs. controls. We also computed inter-expert reliability in SS scoring and found a significantly lower reliability in scoring definite SS in patients when compared to controls. How neurodegeneration in PD could influence SS characteristics is discussed. We also note that the SS morphological changes observed here may affect automatic detection of SS in patients with PD or other neurodegenerative disorders (NDDs). PMID:25983685
NASA Astrophysics Data System (ADS)
Fiore, C. L.; Rowan, W. L.; Dominguez, A.; Hubbard, A. E.; Ince-Cushman, A.; Greenwald, M. J.; Lin, L.; Marmar, E. S.; Reinke, M.; Rice, J. E.; Zhurovich, K.
2007-11-01
Internal transport barrier plasmas can arise spontaneously in ohmic Alcator C-Mod plasmas where an EDA H-mode has been developed by magnetic field ramping. These ohmic ITBs share the hallmarks of ITBs created with off-axis ICRF injection in that they have highly peaked density and pressure profiles and the peaking can be suppressed by on-axis ICRF. There is a reduction of particle and thermal flux in the barrier region which then allows the neoclassical pinch to peak the central density. Recent work on ITB onset conditions [1] which was motivated by turbulence studies [2] points to the broadening of the Ti profile with off-axis ICRF acting to reduce the ion temperature gradient. This suppresses ITG instability driven particle fluxes, which is thought to be the primary mechanism for ITB formation. The object of this study is to examine the characteristics of ohmic ITBs to find whether the stability of plasmas and the plasma parameters support the onset model. [1]K. Zhurovich, et al., To be published in Nuclear Fusion [2] D. R. Ernst, et al., Phys. Plasmas 11, 2637 (2004)
Electron density and plasma dynamics of a colliding plasma experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wiechula, J., E-mail: wiechula@physik.uni-frankfurt.de; Schönlein, A.; Iberler, M.
2016-07-15
We present experimental results of two head-on colliding plasma sheaths accelerated by pulsed-power-driven coaxial plasma accelerators. The measurements have been performed in a small vacuum chamber with a neutral-gas prefill of ArH{sub 2} at gas pressures between 17 Pa and 400 Pa and load voltages between 4 kV and 9 kV. As the plasma sheaths collide, the electron density is significantly increased. The electron density reaches maximum values of ≈8 ⋅ 10{sup 15} cm{sup −3} for a single accelerated plasma and a maximum value of ≈2.6 ⋅ 10{sup 16} cm{sup −3} for the plasma collision. Overall a raise of the plasma density by a factor ofmore » 1.3 to 3.8 has been achieved. A scaling behavior has been derived from the values of the electron density which shows a disproportionately high increase of the electron density of the collisional case for higher applied voltages in comparison to a single accelerated plasma. Sequences of the plasma collision have been taken, using a fast framing camera to study the plasma dynamics. These sequences indicate a maximum collision velocity of 34 km/s.« less
Ionospheric Scintillation Activity Over Ilorin, Nigeria
NASA Astrophysics Data System (ADS)
Oladipo, O. A.; Adeniyi, J. O.; Doherty, P. H.; Radicella, S. M.; Adimula, I. A.; Olawepo, A. O.
2018-02-01
Scintillation of radio waves in the L-band frequency is a regular occurrence at the equatorial and auroral regions at night most especially during high solar activity periods. Scintillation is caused by plasma density irregularities, and this could cause loss of lock of Global Navigation Satellite System (GNSS) signals leading to impairment of the applications that rely on this system. A study on the occurrence of scintillation activity over Ilorin (latitude = 8.48°N, longitude = 4.67°W, and geomagnetic latitude = 1.89°S), Nigeria was done using S4 index data from NovAtel GPStation-2 receiver (2009-2012) and NovAtel GPStation-6 receiver (August 2013 to December 2016) which are both located at this station. The solar maximum period of the solar cycle 24 is located well within the period of this investigation; hence, this study provides opportunity to see the occurrence pattern of scintillation during different seasons as well as the pattern from low solar activity to solar maximum. The results obtained showed that scintillation occurs between 21:00 LT and 04:00 LT at the peak of the occurrence in 2014. The time window of occurrence decreases with decrease in solar activity. Similarly, scintillation activity was observed to be more regular during high solar activity and it has two peaks of occurrence in March and October. A solar activity trend was observed in scintillation occurrence; scintillation activity increases with increase in the level of solar activity.
NASA Astrophysics Data System (ADS)
Margarone, D.; Krása, J.; Giuffrida, L.; Picciotto, A.; Torrisi, L.; Nowak, T.; Musumeci, P.; Velyhan, A.; Prokůpek, J.; Láska, L.; Mocek, T.; Ullschmied, J.; Rus, B.
2011-05-01
Multi-MeV beams of light ions have been produced using the 300 picosecond, kJ-class iodine laser, operating at the Prague Asterix Laser System facility in Prague. Real-time ion diagnostics have been performed by the use of various time-of-flight (TOF) detectors: ion collectors (ICs) with and without absorber thin films, new prototypes of single-crystal diamond and silicon carbide detectors, and an electrostatic ion mass spectrometer (IEA). In order to suppress the long photopeak induced by soft X-rays and to avoid the overlap with the signal from ultrafast particles, the ICs have been shielded with Al foil filters. The application of large-bandgap semiconductor detectors (>3 eV) ensured cutting of the plasma-emitted visible and soft-UV radiation and enhancing the sensitivity to the very fast proton/ion beams. Employing the IEA spectrometer, various ion species and charge states in the expanding laser-plasma have been determined. Processing of the experimental data based on the TOF technique, including estimation of the plasma fast proton maximum and peak energy, ion beam currents and total charge, total number of fast protons, as well as deconvolution processes, ion stopping power, and ion/photon transmission calculations for the different metallic filters used, are reported.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Higashiguchi, Takeshi; Yugami, Noboru; CREST, Japan Science and Technology Agency, 4-1-8 Honcho, Kanagawa, Saitama 332-0012
2010-04-15
We demonstrated the production of an optical waveguide in a capillary discharge-produced plasma using a cylindrical capillary. Plasma parameters of its waveguide were characterized by use of both a Nomarski laser interferometer and a hydrogen plasma line spectrum. A space-averaged maximum temperature of 3.3 eV with electron densities of the order of 10{sup 17} cm{sup -3} was observed at a discharge time of 150 ns and a maximum discharge current of 400 A. An ultrashort, intense laser pulse was guided by use of this plasma channel.
2014-06-19
excited by a sine -wave signal with peak- to-peak amplitudes between 7.2 kV and 10 kV, and frequencies of 2.5 kHz and 4 kHz. The results indicate that the...side length of 0.68 m, made of transparent PMMA, to isolate it from ambient disturbances. The plasma actuator was excited by a sine -wave signal, which... Portugal , 2008. 6Hanson, R., Houser, N., and Lavoie, P., “Dielectric material degradation monitoring of dielectric barrier discharge plasma actuators
1999-11-01
Maximum force (N) on the ankle, knee and hip while walking at 3.5 mph 51 23. Maximum heel- strike force (N) while walking at 3.5 mph ^.ർ 24...to first force peak while running at 6.5 mph ’.""."..62 34. Variables relating to force low point between the heel- strike and push-off peak...was lower peak deceleration and lower peak pressure at the heel than at the forefoot . In the second phase of their research, Hamill and Bensel (7, 8
A model for chorus associated electrostatic bursts
NASA Technical Reports Server (NTRS)
Grabbe, C. L.
1984-01-01
The linear theory of the generation of electrostatic bursts of noise by electrons trapped in chorus wave packets is developed for a finite temperature electron beam and a Maxwellian elecron and ion background. The growth rates determined qualitatively in good agreement with those obtained by previous authors from a more idealized model. Two connected instability mechanisms seem to be occurring: a beam plasma (electron-ion two-stream) instability commonly associated with intensification of the chorus power levels, and a transitional or borderline resistive medium instability commonly associated with chorus hooks. The physical reasons for the two mechanisms is discussed. In the second case electron beams are difficult to identify in the particle data. An expression is obtained for the maximum growth rate in terms of the ratios of the beam and electron thermal velocities to the beam velocity, and of the beam density to plasma density. It is anticipated that this may allow the observed peak in the electrostatic noise spectrum to be used as a diagnostic for the beam characteristics. Previously announced in STAR as N84-12832
Experimental demonstration of fusion-relevant conditions in magnetized liner inertial fusion
Gomez, Matthew R.; Slutz, Stephen A..; Sefkow, Adam B.; ...
2014-10-06
This Letter presents results from the first fully integrated experiments testing the magnetized liner inertial fusion concept [S.A. Slutz et al., Phys. Plasmas 17, 056303 (2010)], in which a cylinder of deuterium gas with a preimposed axial magnetic field of 10 T is heated by Z beamlet, a 2.5 kJ, 1 TW laser, and magnetically imploded by a 19 MA current with 100 ns rise time on the Z facility. Despite a predicted peak implosion velocity of only 70 km/s, the fuel reaches a stagnation temperature of approximately 3 keV, with T e ≈ T i, and produces up tomore » 2e12 thermonuclear DD neutrons. In this study, X-ray emission indicates a hot fuel region with full width at half maximum ranging from 60 to 120 μm over a 6 mm height and lasting approximately 2 ns. The number of secondary deuterium-tritium neutrons observed was greater than 10 10, indicating significant fuel magnetization given that the estimated radial areal density of the plasma is only 2 mg/cm 2.« less
Complex dielectric properties of anhydrous polycrystalline glucose in the terahertz region
NASA Astrophysics Data System (ADS)
Sun, P.; Liu, W.; Zou, Y.; Jia, Qiong Z.; Li, Jia Y.
2015-03-01
We utilized terahertz time-domain spectroscopy (THz-TDS) to investigate the complex dielectric properties of solid polycrystalline material of anhydrous glucose (D-(+)-glucose with purity >99.9%). THz transmission spectra of samples were measured from 0.2 to 2.2 THz. The samples were prepared into tablets with thicknesses of 0.362, 0.447, 0.504, 0.522 and 0.626 mm, respectively. The imaginary part of the complex dielectric function of polycrystalline glucose showed that there were multiple characteristic absorption peaks at 1.232, 1.445, 1.522, 1.608, 1.811 and 1.987 THz, respectively. Moreover, for a given characteristic absorption peak, the real part of the complex dielectric function showed anomalous dispersion within the full width half maximum (FWHM) of the absorption peak. Both finite difference time-domain (FDTD) numerical simulations and experimental results showed that the complex dielectric function of anhydrous polycrystalline glucose fits well with the Lorentz dielectric mode. The plasma oscillation frequency was below the frequency of the light waves suggesting that the light waves passed through the polycrystalline glucose tablets. Calculations based on density functional theory (DFT) showed that the characteristic absorption peaks of polycrystalline glucose originated mainly from collective intermolecular vibrations such as hydrogen bonds and crystal phonon modes. The THz radiation can excite the vibrational or rotational energy levels of the biological macromolecules. This leads to changes in their spatial configuration or interactions. This study showed that THz-TDS has potential applications in biological and pharmaceutical research and food industry.
Effect of applied magnetic nozzle on an MPD Thruster
NASA Astrophysics Data System (ADS)
Ando, Akira; Izawa, Yuki; Okawa, Kohei; Hashima, Yoko; Watanabe, Hiroshi; Tanaka, Nozomi
2012-10-01
Electric propulsion systems are suitable for long-term mission in space due to its higher specific impulse. An Magneto-Plasma-Dynamic Thruster (MPDT) is one of the promising thrusters of high power electric propulsion systems. It has been reported that the thrust performance of an MPDT can be improved by applying an axial magnetic field on it. In order to investigate the effect of applied field on an MPDT, we have investigated plume plasma parameters and thrust performance in an applied field MPDT. Different types of divergent magnetic nozzle were applied to an MPDT, and thrust was measured using a pendulum type thrust target. Experiments were performed with hydrogen, helium, and argon as propellant gas. Thrust increased with a discharge current up to 6kA and applied magnetic field up to 0.4T. Maximum thrust of 7N was obtained when the peak position of the applied magnetic field was set upstream of the muzzle of the MPDT. The highest thrust performance was obtained with hydrogen gas with divergent magnetic nozzle applied to the MPDT.
Two-color ionization injection using a plasma beatwave accelerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schroeder, C. B.; Benedetti, C.; Esarey, E.
Two-color laser ionization injection is a method to generate ultra-low emittance (sub-100 nm transverse normalized emittance) beams in a laser-driven plasma accelerator. A plasma beatwave accelerator is proposed to drive the plasma wave for ionization injection, where the beating of the lasers effectively produces a train of long-wavelength pulses. The plasma beatwave accelerator excites a large amplitude plasma wave with low peak laser electric fields, leaving atomically-bound electrons with low ionization potential. A short-wavelength, low-amplitude ionization injection laser pulse (with a small ponderomotive force and large peak electric field) is used to ionize the remaining bound electrons at a wakemore » phase suitable for trapping, generating an ultra-low emittance electron beam that is accelerated in the plasma wave. Using a plasma beatwave accelerator for wakefield excitation, compared to short-pulse wakefield excitation, allows for a lower amplitude injection laser pulse and, hence, a lower emittance beam may be generated.« less
Two-color ionization injection using a plasma beatwave accelerator
Schroeder, C. B.; Benedetti, C.; Esarey, E.; ...
2018-01-10
Two-color laser ionization injection is a method to generate ultra-low emittance (sub-100 nm transverse normalized emittance) beams in a laser-driven plasma accelerator. A plasma beatwave accelerator is proposed to drive the plasma wave for ionization injection, where the beating of the lasers effectively produces a train of long-wavelength pulses. The plasma beatwave accelerator excites a large amplitude plasma wave with low peak laser electric fields, leaving atomically-bound electrons with low ionization potential. A short-wavelength, low-amplitude ionization injection laser pulse (with a small ponderomotive force and large peak electric field) is used to ionize the remaining bound electrons at a wakemore » phase suitable for trapping, generating an ultra-low emittance electron beam that is accelerated in the plasma wave. Using a plasma beatwave accelerator for wakefield excitation, compared to short-pulse wakefield excitation, allows for a lower amplitude injection laser pulse and, hence, a lower emittance beam may be generated.« less
Reconstruction of Pressure Profile Evolution during Levitated Dipole Experiments
NASA Astrophysics Data System (ADS)
Mauel, M.; Garnier, D.; Boxer, A.; Ellsworth, J.; Kesner, J.
2008-11-01
Magnetic levitation of the LDX superconducting dipole causes significant changes in the measured diamagnetic flux and what appears to be an isotropic plasma pressure profile (p˜p||). This poster describes the reconstruction of plasma current and plasma pressure profiles from external measurements of the equilibrium magnetic field, which vary substantially as a function of time depending upon variations in neutral pressure and multifrequency ECRH power levels. Previous free-boundary reconstructions of plasma equilibrium showed the plasma to be anisotropic and highly peaked at the location of the cyclotron resonance of the microwave heating sources. Reconstructions of the peaked plasma pressures confined by a levitated dipole incorporate the small axial motion of the dipole (±5 mm), time varying levitation coil currents, eddy currents flowing in the vacuum vessel, constant magnetic flux linking the superconductor, and new flux loops located near the hot plasma in order to closely couple to plasma current and dipole current variations. I. Karim, et al., J. Fusion Energy, 26 (2007) 99.
Nanomaterial release characteristics in a single-walled carbon nanotube manufacturing workplace
NASA Astrophysics Data System (ADS)
Ji, Jun Ho; Kim, Jong Bum; Lee, Gwangjae; Bae, Gwi-Nam
2015-02-01
As carbon nanotubes (CNTs) are widely used in various applications, exposure assessment also increases in importance with other various toxicity tests for CNTs. We conducted 24-h continuous nanoaerosol measurements to identify possible nanomaterial release in a single-walled carbon nanotube (SWCNT) manufacturing workplace. Four real-time aerosol instruments were used to determine the nanosized and microsized particle numbers, particle surface area, and carbonaceous species. Task-based exposure assessment was carried out for SWCNT synthesis using the arc plasma and thermal decomposition processes to remove amorphous carbon components as impurities. During the SWCNT synthesis, the black carbon (BC) concentration was 2-12 μg/m3. The maximum BC mass concentrations occurred when the synthesis chamber was opened for harvesting the SWCNTs. The number concentrations of particles with sizes 10-420 nm were 10,000-40,000 particles/cm3 during the tasks. The maximum number concentration existed when a vacuum pump was operated to remove exhaust air from the SWCNT synthesis chamber due to the penetration of highly concentrated oil mists through the window opened. We analyzed the particle mass size distribution and particle number size distribution for each peak episode. Using real-time aerosol detectors, we distinguished the SWCNT releases from background nanoaerosols such as oil mist and atmospheric photochemical smog particles. SWCNT aggregates with sizes of 1-10 μm were mainly released from the arc plasma synthesis. The harvesting process was the main release route of SWCNTs in the workplace.
Probing RFP Density Limits and the Interaction of Pellet Fueling and NBI Heating on MST
NASA Astrophysics Data System (ADS)
Caspary, K. J.; Chapman, B. E.; Anderson, J. K.; Limbach, S. T.; Oliva, S. P.; Sarff, J. S.; Waksman, J.; Combs, S. K.; Foust, C. R.
2013-10-01
Pellet fueling on MST has previously achieved Greenwald fractions of up to 1.5 in 200 kA improved confinement discharges. Additionally, pellet fueling to densities above the Greenwald limit in 200 kA standard discharges resulted in early termination of the plasma, but pellet size was insufficient to exceed the limit for higher current discharges. To this end, the pellet injector on MST has been upgraded to increase the maximum fueling capability by increasing the size of the pellet guide tubes, which constrain the lateral motion of the pellet in flight, to accommodate pellets of up to 4.0 mm in diameter. These 4.0 mm pellets are capable of triggering density limit terminations for MST's peak current of 600 kA. An unexpected improvement in the pellet speed and mass control was also observed compared to the smaller diameter pellets. Exploring the effect of increased density on NBI particle and heat deposition shows that for MST's 1 MW tangential NBI, core deposition of 25 keV neutrals is optimized for densities of 2-3 × 1019 m-3. This is key for beta limit studies in pellet fueled discharges with improved confinement where maximum NBI heating is desired. An observed toroidal deflection of pellets injected into NBI heated discharges is consistent with asymmetric ablation due to the fast ion population. In 200 kA improved confinement plasmas with NBI heating, pellet fueling has achieved a Greenwald fraction of 2.0. Work supported by US DoE.
Stereoselective pharmacokinetics of moguisteine metabolites in healthy subjects.
Bernareggi, A; Crema, A; Carlesi, R M; Castoldi, D; Ratti, E; Renoldi, M I; Ratti, D; Ceserani, R; Tognella, S
1995-01-01
We studied the pharmacokinetics of moguisteine, a racemic non-narcotic peripheral antitussive drug, in 12 healthy male subjects after a single oral administration of 200 mg. The unchanged drug was absent in plasma and urine of all subjects. Moguisteine was immediately and completely hydrolyzed to its main active metabolite, the free carboxylic acid M1. Therefore, we evaluated the kinetic profiles of M1, of its enantiomers R(+)-M1 and S(-)-M1, and of M1 sulfoxide optical isomers M2/I and M2/II by conventional and stereospecific HPLC. Maximum plasma concentrations for M1 (2.83 mg/l), M2/I (0.26 mg/l) and M2/II (0.40 mg/l), were respectively reached at 1.3, 1.6 and 1.5 h after moguisteine administration. Plasma concentrations declined after the peak with mean apparent terminal half-lives of 0.65 h (M1), 0.88 h (M2/I) and 0.84 h (M2/II). Most of the administered dose was recovered in urine within 6 h from moguisteine treatment. The systemic and renal clearance values indicated high renal extraction ratio for all moguisteine metabolites, and particularly for M1 sulfoxide optical isomers. Plasma concentration-time profiles and urinary excretion patterns for M1 enantiomers R(+)-M1 and S(-)-M1 were quite similar. Thus, for later moguisteine pharmacokinetic evaluations the investigation of the plasma concentration-time curve and the urinary excretion of the sole racemic M1 through non-stereospecific analytical methods may suffice in most cases.
Seasonal and daily plasma corticosterone rhythms in American toads, Bufo americanus
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pancak, M.K.; Taylor, D.H.
1983-06-01
Concentrations of corticosterone were measured in the plasma of American toads, Bufo americanus, on a seasonal basis using a radioimmunoassay technique. Two populations of toads, maintained under different light conditions, were monitored to observe the effects of photoperiod on the seasonal rhythm of plasma corticosterone. Under a natural photoperiod toads demonstrated a rhythm consisting of a spring peak and a fall peak in corticosterone concentration. Toads maintained under a 12L:12D photoperiod all year round demonstrated a similar rhythm with peaks in the spring and fall. This suggests that an endogenous (circannual) rhythm of corticosterone may be playing an important rolemore » in the seasonal change of overt behavior and physiology of Bufo americanus. A daily rhythm of corticosterone was also detected in toads when blood samples were taken every 4 hr. When compared to a previously published circadian rhythm study of locomotor activity, the surge in corticosterone concentration for the day occurred at 1730 just prior to the peak in locomotor activity.« less
Evolution of ionosphere-thermosphere (IT) parameters in the cusp region related to ion upflow events
NASA Astrophysics Data System (ADS)
Kervalishvili, Guram; Lühr, Hermann
2017-04-01
In this study we investigate the relationships of various IT parameters with the intensity of vertical ion flow. Our study area is the ionospheric cusp region in the northern hemisphere. The approach uses superposed epoch analysis (SEA) method, centered alternately on peaks of the three different variables: neutral density enhancement, vertical plasma flow, and electron temperature. Further parameters included are large-scale field-aligned currents (LSFACs) and thermospheric zonal wind velocity profiles over magnetic latitude (MLat), which are centered at the event time and location. The dependence on the interplanetary magnetic field (IMF) By component orientation and the local (Lloyd) season is of particular interest. Our investigations are based on CHAMP and DMSP (F13 and F15) satellite observations and the OMNI online database collected during the years 2002-2007. The three Lloyd seasons of 130 days each are defined as follows: local winter (1 January ± 65 days), combined equinoxes (1 April and 1 October ± 32 days), and local summer (1 July ± 65 days). A period of 130 days corresponds to the time needed by CHAMP to sample all local times. The SEA MLat profiles with respect to neutral density enhancement and vertical plasma flow peaks show no significant but only slight (decreasing towards local summer) seasonal variations for both IMF By orientations. The latitude profiles of median LSFACs show a clear dependence on the IMF By orientation. As expected, the maximum and minimum values of LSFAC amplitudes are increasing towards local summer for both IMF By signs. With respect to zero epoch latitude, FAC peaks appear equatorward (negative MLat) related to Region 1 (R1) and poleward (positive MLat) to Region 0 (R0) FACs. However, there is an imbalance between the amplitudes of LSFACs, depending on the current latitude. R1 currents are systematically stronger than R0 FACs. A somewhat different distribution of density enhancements and large-scale FACs emerges when the SEA is centered on electron temperature peaks. As expected, the background electron temperature increases towards summer and shows no dependence on the IMF By orientation. In contrast to the previous sorting the mass density enhancement shows a dependence on the IMF By sign and increases towards local summer in case of IMF By<0. As before LSFAC peak values are increasing towards local summer, but there is no clear latitudinal profile of upward and downward FACs. We think that intense precipitation of soft electrons (<100 eV) cause the electron temperature enhancement in the cusp region. But there is no direct dependence on the FAC intensity. But for neutral density enhancement and vertical plasma flow the combination of Joule heating and soft electron precipitation, causing electron temperature and conductivity enhancements, are required.
Calculating the radiation characteristics of accelerated electrons in laser-plasma interactions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, X. F.; Graduate School of Engineering, Utsunomiya University, 7-1-2 Yohtoh, Utsunomiya 321-8585; Yu, Q.
2016-03-15
In this paper, we studied the characteristics of radiation emitted by electrons accelerated in a laser–plasma interaction by using the Lienard–Wiechert field. In the interaction of a laser pulse with a underdense plasma, electrons are accelerated by two mechanisms: direct laser acceleration (DLA) and laser wakefield acceleration (LWFA). At the beginning of the process, the DLA electrons emit most of the radiation, and the DLA electrons emit a much higher peak photon energy than the LWFA electrons. As the laser–plasma interaction progresses, the LWFA electrons become the major radiation emitter; however, even at this stage, the contribution from DLA electronsmore » is significant, especially to the peak photon energy.« less
PMT-scintillator system set up for D-D neutron TOF measurements in INTI plasma focus device
NASA Astrophysics Data System (ADS)
Damideh, V.; Saw, S. H.; Sadighzadeh, A.; Ali, J.; Rawat, R. S.; Lee, P.; Lee, S.
2017-03-01
This paper summarizes a Photomultiplier-Scintillator diagnostic system for use in our plasma focus experiments at the Center for Plasma Research INTI IU. The system features an anode-grounded high pulse linearity voltage divider and uses NE102A plastic scintillators. It has detected D-D neutrons in INTI plasma focus device with clear and high signal to noise ratio. Neutron TOF of 120 ns has been measured from the time difference between hard x-ray pulse peak and neutron peak time over a flight path of 2.6±0.01 m; giving energy of 2.5±0.1 MeV for these side-on neutrons.
NASA Astrophysics Data System (ADS)
Kohnová, Silvia; Papaioannou, George; Bacigál, Tomáš; Szolgay, Ján; Hlavčová, Kamila; Loukas, Athanasios; Výleta, Roman
2017-04-01
Flood frequency analysis is often performed as a univariate analysis of flood peaks using a suitable theoretical probability distribution of the annual maximum flood peaks or peak over threshold values. However, also other flood attributes, such as flood volume and duration, are often necessary for the design of hydrotechnical structures and projects. In this study, the suitability of various copula families for a bivariate analysis of peak discharges and flood volumes has been tested on the streamflow data from gauging stations along the whole Danube River. Kendall's rank correlation coefficient (tau) quantifies the dependence between flood peak discharge and flood volume settings. The methodology is tested on two different data samples: 1) annual maximum flood (AMF) peaks with corresponding flood volumes, which is a typical choice for engineering studies and 2). annual maximum flood (AMF) peaks combined with annual maximum flow volumes of fixed durations at 5, 10, 15, 20, 25, 30 and 60 days, which can be regarded as a regime analysis of the dependence between the extremes of both variables in a given year. The bivariate modelling of the peak discharge - flood volume couples is achieved with the use of the the following copulas: Ali-Mikhail-Haq (AMH), Clayton, Frank, Joe, Gumbel, HuslerReiss, Galambos, Tawn, Normal, Plackett and FGM, respectively. Scatterplots of the observed and simulated peak discharge - flood volume pairs and goodness-of-fit tests have been used to assess the overall applicability of the copulas as well as observing any changes in suitable models along the Danube River. The results indicate that, almost all of the considered Archimedean class copulas (e.g. Frank, Clayton and Ali-Mikhail-Haq) perform better than the other copula families selected for this study, and that for the second data samples mostly the upper-tail-flat copulas were suitable.
A Survey of Cassini CAPS Ion Observations During Titan Flybys TA-T83
NASA Astrophysics Data System (ADS)
Woodson, A. K.; Johnson, R. E.; Smith, H. T.; Crary, F. J.
2015-12-01
The Cassini Plasma Spectrometer (CAPS) sampled Titan's plasma environment during each of 83 encounters with the moon between orbit insertion on June 30, 2004 and June 1, 2012. The CAPS Ion Mass Spectrometer (IMS) acquired energy- and mass-per-charge-discriminated time-of-flight (TOF) spectra associated with ionospheric H+, H2+, H3+, CHx+, and C2Hx+ during at least 68 of those encounters. Herein we discuss ion energy distributions extracted from these spectra, each accumulated over an ~4 minute interval along the spacecraft trajectory. This is accomplished by fitting calibration peak models to TOF spectra in order to determine the TOF range associated with each aforementioned ion group, and then summing counts over each TOF range to obtain well-resolved energy peaks for each group. Energy distributions are determined by fitting the logistic power peak function to each of the resulting energy spectra. We then plot the resulting distribution parameters (peak energy, peak amplitude, and peak width or temperature) for each species and each encounter against Titan latitude, longitude, and altitude to generate a map of ion parameters. In addition, the encounters are grouped according to ambient plasma and magnetic field measurements in order to characterize the ion distribution parameters in different regions of Saturn's magnetosphere.
Kinetic Features in the Ion Flux Spectrum
NASA Astrophysics Data System (ADS)
Vafin, S.; Riazantseva, M.; Yoon, P. H.
2017-11-01
An interesting feature of solar wind fluctuations is the occasional presence of a well-pronounced peak near the spectral knee. These peaks are well investigated in the context of magnetic field fluctuations in the magnetosheath and they are typically related to kinetic plasma instabilities. Recently, similar peaks were observed in the spectrum of ion flux fluctuations of the solar wind and magnetosheath. In this paper, we propose a simple analytical model to describe such peaks in the ion flux spectrum based on the linear theory of plasma fluctuations. We compare our predictions with a sample observation in the solar wind. For the given observation, the peak requires ˜10 minutes to grow up to the observed level that agrees with the quasi-linear relaxation time. Moreover, our model well reproduces the form of the measured peak in the ion flux spectrum. The observed lifetime of the peak is about 50 minutes, which is relatively close to the nonlinear Landau damping time of 30-40 minutes. Overall, our model proposes a plausible scenario explaining the observation.
Challenges in Defining Tsunami Wave Height
NASA Astrophysics Data System (ADS)
Stroker, K. J.; Dunbar, P. K.; Mungov, G.; Sweeney, A.; Arcos, N. P.
2017-12-01
The NOAA National Centers for Environmental Information (NCEI) and co-located World Data Service for Geophysics maintain the global tsunami archive consisting of the historical tsunami database, imagery, and raw and processed water level data. The historical tsunami database incorporates, where available, maximum wave heights for each coastal tide gauge and deep-ocean buoy that recorded a tsunami signal. These data are important because they are used for tsunami hazard assessment, model calibration, validation, and forecast and warning. There have been ongoing discussions in the tsunami community about the correct way to measure and report these wave heights. It is important to understand how these measurements might vary depending on how the data were processed and the definition of maximum wave height. On September 16, 2015, an 8.3 Mw earthquake located 48 km west of Illapel, Chile generated a tsunami that was observed all over the Pacific region. We processed the time-series water level data for 57 tide gauges that recorded this tsunami and compared the maximum wave heights determined from different definitions. We also compared the maximum wave heights from the NCEI-processed data with the heights reported by the NOAA Tsunami Warning Centers. We found that in the near field different methods of determining the maximum tsunami wave heights could result in large differences due to possible instrumental clipping. We also found that the maximum peak is usually larger than the maximum amplitude (½ peak-to-trough), but the differences for the majority of the stations were <20 cm. For this event, the maximum tsunami wave heights determined by either definition (maximum peak or amplitude) would have validated the forecasts issued by the NOAA Tsunami Warning Centers. Since there is currently only one field in the NCEI historical tsunami database to store the maximum tsunami wave height, NCEI will consider adding an additional field for the maximum peak measurement.
Challenges in Defining Tsunami Wave Heights
NASA Astrophysics Data System (ADS)
Dunbar, Paula; Mungov, George; Sweeney, Aaron; Stroker, Kelly; Arcos, Nicolas
2017-08-01
The National Oceanic and Atmospheric Administration (NOAA) National Centers for Environmental Information (NCEI) and co-located World Data Service for Geophysics maintain the global tsunami archive consisting of the historical tsunami database, imagery, and raw and processed water level data. The historical tsunami database incorporates, where available, maximum wave heights for each coastal tide gauge and deep-ocean buoy that recorded a tsunami signal. These data are important because they are used for tsunami hazard assessment, model calibration, validation, and forecast and warning. There have been ongoing discussions in the tsunami community about the correct way to measure and report these wave heights. It is important to understand how these measurements might vary depending on how the data were processed and the definition of maximum wave height. On September 16, 2015, an 8.3 M w earthquake located 48 km west of Illapel, Chile generated a tsunami that was observed all over the Pacific region. We processed the time-series water level data for 57 coastal tide gauges that recorded this tsunami and compared the maximum wave heights determined from different definitions. We also compared the maximum wave heights from the NCEI-processed data with the heights reported by the NOAA Tsunami Warning Centers. We found that in the near field different methods of determining the maximum tsunami wave heights could result in large differences due to possible instrumental clipping. We also found that the maximum peak is usually larger than the maximum amplitude (½ peak-to-trough), but the differences for the majority of the stations were <20 cm. For this event, the maximum tsunami wave heights determined by either definition (maximum peak or amplitude) would have validated the forecasts issued by the NOAA Tsunami Warning Centers. Since there is currently only one field in the NCEI historical tsunami database to store the maximum tsunami wave height for each tide gauge and deep-ocean buoy, NCEI will consider adding an additional field for the maximum peak measurement.
10th order laterally coupled GaN-based DFB laser diodes with V-shaped surface gratings
NASA Astrophysics Data System (ADS)
Kang, J. H.; Wenzel, H.; Hoffmann, V.; Freier, E.; Sulmoni, L.; Unger, R.-S.; Einfeldt, S.; Wernicke, T.; Kneissl, M.
2018-02-01
Single longitudinal mode operation of laterally coupled distributed feedback (DFB) laser diodes (LDs) based on GaN containing 10th-order surface Bragg gratings with V-shaped grooves is demonstrated using i-line stepper lithography and inductively coupled plasma etching. A threshold current of 82 mA, a slope efficiency of 1.7 W/A, a single peak emission at 404.5 nm with a full width at half maximum of 0.04 nm and a side mode suppression ratio of > 23 dB at an output power of about 46 mW were achieved under pulsed operation. The shift of the lasing wavelength of DFB LDs with temperature was around three times smaller than that of conventional ridge waveguide LDs.
Quantum-confined Stark effect at 1.3 μm in Ge/Si(0.35)Ge(0.65) quantum-well structure.
Rouifed, Mohamed Said; Chaisakul, Papichaya; Marris-Morini, Delphine; Frigerio, Jacopo; Isella, Giovanni; Chrastina, Daniel; Edmond, Samson; Le Roux, Xavier; Coudevylle, Jean-René; Vivien, Laurent
2012-10-01
Room-temperature quantum-confined Stark effect in a Ge/SiGe quantum-well structure is reported at the wavelength of 1.3 μm. The operating wavelength is tuned by the use of strain engineering. Low-energy plasma-enhanced chemical vapor deposition is used to grow 20 periods of strain-compensated quantum wells (8 nm Ge well and 12 nm Si(0.35)Ge(0.65) barrier) on Si(0.21)Ge(0.79) virtual substrate. The fraction of light absorbed per well allows for a strong modulation around 1.3 μm. The half-width at half-maximum of the excitonic peak of only 12 meV allows for a discussion on physical mechanisms limiting the performances of such devices.
Simulation of magnetic holes formation in the magnetosheath
NASA Astrophysics Data System (ADS)
Ahmadi, Narges; Germaschewski, Kai; Raeder, Joachim
2017-12-01
Magnetic holes have been frequently observed in the Earth's magnetosheath and are believed to be the consequence of the nonlinear evolution of the mirror instability. Mirror mode perturbations mainly form as magnetic holes in regions where the plasma is marginally mirror stable with respect to the linear instability criterion. We present an expanding box particle-in-cell simulation to mimic the changing conditions in the magnetosheath as the plasma is convected through it that produces mirror mode magnetic holes. We show that in the initial nonlinear evolution, where the plasma conditions are mirror unstable, the magnetic peaks are dominant, while later, as the plasma relaxes toward marginal stability, the fluctuations evolve into deep magnetic holes. While the averaged plasma parameters in the simulation remain close to the mirror instability threshold, the local plasma in the magnetic holes is highly unstable to mirror instability and locally mirror stable in the magnetic peaks.
[Pharmacokinetics and clinical studies of flomoxef in the pediatric field].
Motohiro, T; Oda, K; Aramaki, M; Kawakami, A; Tanaka, K; Koga, T; Shimada, Y; Tomita, S; Sakata, Y; Fujimoto, T
1987-08-01
Flomoxef (FMOX, 6315-S), a new intravenous cephem antibiotics, was administered to a total of 11 cases with their ages ranging from 7 years and 4 months to 10 years and 10 months. Among them, two were administered with (FMOX at) a dose level of 10 mg/kg, three each with 20 mg/kg and 40 mg/kg using one shot intravenous injection, and the remaining 3 with 40 mg/kg by intravenous drip infusion over 30 minutes. Plasma concentrations, urine concentrations and urinary recovery rates were determined. The clinical efficacy of FMOX was evaluated in 2 cases with tonsillitis, 45 with acute pneumonia, 10 with urinary tract infections, 2 with purulent lymphadenitis, and 2 with abscess, a total of 61 cases. Of these cases, one case of pneumonia in which a side effect occurred was excluded from the evaluation because the treatment was interrupted short of the required period. In the remaining 60 cases, the mean daily dose was 79.3 mg/kg in 3 or 4 divided doses and, except one case treated by 30-minute intravenous drip infusion, all cases were treated by one shot intravenous injection for a mean period of 6 days. Bacteriological effects of FMOX, its side effects and influences on laboratory test values were also investigated. 1. Maximum plasma concentrations after one shot intravenous injections of FMOX occurred at 5 minutes after administration regardless of dose levels (10 mg/kg in 2 cases, 20 mg/kg in 3 and 40 mg/kg in 3). Mean peak values obtained upon the 3 different dose levels were 62.5, 103.1 and 244.7 micrograms/ml, respectively. Mean plasma half-lives were 0.670, 0.915 and 0.595 hour, and mean AUCs were 33.0, 65.2 and 133.1 micrograms.hr/ml, respectively. Thus, a positive dose-response relationship was found among the 3 doses. 2. Plasma concentrations after 30-minute intravenous drip infusions of FMOX at 40 mg/kg always reached a peak at 30 minutes after the initiation of infusion, i.e. at the completion of infusion, and the mean value for 3 administrations was 151.0 micrograms/ml. The mean half-life was 0.973 hour and the mean AUC was 149.1 micrograms.hr/ml. 3. Maximum concentrations in urine after one shot intravenous injections of FMOX were always obtained in 0 approximately 2 hours after administration regardless of dose levels (10 mg/kg, 2 cases, 20 mg/kg, 3 cases and at 40 mg/kg, 3 cases) and mean values for the 3 dose levels were 2,570, 4,410 and 6,290 micrograms/ml, respectively. Thus, urine concentrations were also dose-dependent.(ABSTRACT TRUNCATED AT 400 WORDS)
Impact of dose on the bioavailability of coffee chlorogenic acids in humans.
Stalmach, Angélique; Williamson, Gary; Crozier, Alan
2014-08-01
Single servings of coffee beverage containing low (412 μmol), medium (635 μmol) and high (795 μmol) amounts of chlorogenic acids were administered to eleven healthy volunteers in a double-blind randomised controlled trial. Analysis of plasma and urine collected for 24 h revealed the presence of 12 metabolites in plasma and 16 metabolites in urine, principally in the form of sulphates, and to a lesser extent glucuronides of caffeic, ferulic, dihydrocaffeic and dihydroferulic acids, as well as intact feruloylquinic and caffeoylquinic acids, and sulphated caffeoylquinic acid lactones. Median values of peak plasma concentrations after increasing doses of chlorogenic acids were 1088, 1526 and 1352 nM. In urine the median amounts of metabolites excreted after 24 h following consumption of the three coffees were 101, 160 and 125 μmol, accounting for 24%, 25% and 16% of the doses ingested. Peak plasma concentration and urinary excretion values showed trends towards a reduced bioavailability of chlorogenic acids associated with the highest dose ingested, when expressed as percentages of intake. Potential biomarkers of coffee intake were identified as feruloylquinic acids and sulphated caffeoylquinic acid lactones in plasma and urine with positive moderate to strong coefficients of determination for peak plasma concentrations (0.60-0.81) and amounts excreted in urine (0.36-0.73) (P < 0.05).
NASA Astrophysics Data System (ADS)
Okada, Katsuyuki; Komatsu, Shojiro; Matsumoto, Seiichiro
2003-11-01
Ion energy distributions (IEDs) and the density of CH3 radicals (n) in a 13.56 MHz radio frequency (rf) low pressure inductively coupled CH4/H2 plasma used for nanocrystalline diamond deposition have been investigated with a quadrupole mass spectrometer. The energy distributions of positive ions were measured in a CH4/H2 plasma with 50 mTorr of the gas pressure at 500 W of the plasma input power, and were compared with those of an Ar plasma. We have found that the IEDs of Ar+, CH4+, and C2H5+ have a nearly monoenergetic peak, and a hump due to a small degree of capacitive coupling. The plasma potentials obtained from the peaks are consistent with the previously reported values measured with a Langmuir probe. On the other hand, the IEDs of H+, H2+, and H3+ have a clear asymmetric double peak due to the modulation of rf driven glow discharge. The n monotonously increases with increasing pressure. The n indicates that CH3 radicals are main precursors for the growth of nanocrystalline diamond. The estimated sticking coefficient of the CH3 radical is comparable with the reported value.
Prostatic origin of a zinc binding high molecular weight protein complex in human seminal plasma.
Siciliano, L; De Stefano, C; Petroni, M F; Vivacqua, A; Rago, V; Carpino, A
2000-03-01
The profile of the zinc ligand high molecular weight proteins was investigated in the seminal plasma of 55 normozoospermic subjects by size exclusion high performance liquid chromatography (HPLC). The proteins were recovered from Sephadex G-75 gel filtration of seminal plasma in three zinc-containing fractions which were then submitted to HPLC analysis. The results were, that in all the samples, the protein profiles showed two peaks with apparent molecular weight of approximately 660 and approximately 250 kDa. Dialysis experiments revealed that both approximately 660 and approximately 250 kDa proteins were able to uptake zinc against gradient indicating their zinc binding capacity. The HPLC analysis of the whole seminal plasma evidenced only the approximately 660 kDa protein complex as a single well quantifying peak, furthermore a positive correlation between its peak area and the seminal zinc values (P < 0.001) was observed. This suggested a prostatic origin of the approximately 660 kDa protein complex which was then confirmed by the seminal plasma HPLC analysis of a subject with agenesis of the Wolffian ducts. Finally the study demonstrated the presence of two zinc binding proteins, approximately 660 and approximately 250 kDa respectively, in human seminal plasma and the prostatic origin of the approximately 660 kDa.
Characteristics of laser produced plasmas of hafnium and tantalum in the 1-7 nm region
NASA Astrophysics Data System (ADS)
Li, Bowen; Otsuka, Takamitsu; Sokell, Emma; Dunne, Padraig; O'Sullivan, Gerry; Hara, Hiroyuki; Arai, Goki; Tamura, Toshiki; Ono, Yuichi; Dinh, Thanh-Hung; Higashiguchi, Takeshi
2017-11-01
Soft X-ray (SXR) spectra from hafnium and tantalum laser produced plasmas were recorded in the 1-7 nm region using two Nd:YAG lasers with pulse lengths of 170 ps and 10 ns, respectively, operating at a range of power densities. The maximum focused peak power density was 2. 3 × 1014 W cm-2 for 170 ps pulses and 1. 8 × 1012 W cm-2 for 10 ns pulses, respectively. Two intense quasicontinuous intensity bands resulting from n = 4 - n = 4 and n = 4 - n = 5 unresolved transition arrays (UTAs) dominate both sets of experimental spectra. Comparison with calculations performed with the Cowan suite of atomic structure codes as well as consideration of previous experimental and theoretical results aided identification of the most prominent features in the spectra. For the 10 ns spectrum, the highest ion stage that could be identified from the n = 4 - n = 5 arrays were lower than silver-like Hf25+ and Ta26+ (which has a 4 d 104 f ground configuration) indicating that the plasma temperature attained was too low to produce ions with an outermost 4 d subshell, while for the 170 ps plasmas the presence of significantly higher stages was deduced and lines due to 4 d-5 p transitions were clearly evident. Furthermore, we show an enhancement of emission from tantalum using dual laser irradiation, and the effect of pre-pulse durations and delay times between two pulses are demonstrated.
MHD limits and plasma response in high-beta hybrid operations in ASDEX Upgrade
NASA Astrophysics Data System (ADS)
Igochine, V.; Piovesan, P.; Classen, I. G. J.; Dunne, M.; Gude, A.; Lauber, P.; Liu, Y.; Maraschek, M.; Marrelli, L.; McDermott, R.; Reich, M.; Ryan, D.; Schneller, M.; Strumberger, E.; Suttrop, W.; Tardini, G.; Zohm, H.; The ASDEX Upgrade Team; The EUROfusion MST1 Team
2017-11-01
The improved H-mode scenario (or high β hybrid operations) is one of the main candidates for high-fusion performance tokamak operation that offers a potential steady-state scenario. In this case, the normalized pressure {{β }N} must be maximized and pressure-driven instabilities will limit the plasma performance. These instabilities could have either resistive ((m = 2, n = 1) and (3,2) neoclassical tearing modes (NTMs)) or ideal character (n = 1 ideal kink mode). In ASDEX Upgrade (AUG), the first limit for maximum achievable {{β }N} is set by the NTMs. The application of pre-emptive electron cyclotron current drive at the q = 2 and q = 1.5 resonant surfaces reduces this problem, so that higher values of {{β }N} can be reached. AUG experiments have shown that, in spite of the fact that hybrids are mainly limited by NTMs, the proximity to the no-wall limit leads to amplification of the external fields that strongly influence the plasma profiles. For example, rotation braking is observed throughout the plasma and peaks in the core. In this situation, even small external fields are amplified and their effect becomes visible. To quantify these effects, the plasma response to the magnetic fields produced by B-coils is measured as {{β }N} approaches the no-wall limit. These experiments and corresponding modeling allow the identification of the main limiting factors, which depend on the stabilizing influence of the conducting components facing the plasma surface, the existence of external actuators, and the kinetic interaction between the plasma and the marginally stable ideal modes. Analysis of the plasma reaction to external perturbations allowed us to identify optimal correction currents for compensating the intrinsic error field in the device. Such correction, together with the analysis of kinetic effects, will help to increase {{β }N} further in future experiments.
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Sather, T. M.
2000-01-01
The purpose of this investigation was to test the hypothesis that peripheral vasoconstriction and orthostatic tolerance are associated with increased circulating plasma concentrations of noradrenaline, vasopressin and renin-angiotensin. Sixteen men were categorized as having high (HT, n=9) or low (LT, n=7) tolerance to lower body negative pressure (LBNP) based on whether the endpoint of their pre-syncopal-limited LBNP (peak LBNP) exposure exceeded -60 mmHg. The two groups were matched for age, height, weight, leg volume, blood volume and maximal oxygen uptake, as well as baseline blood volume and plasma concentrations of vasoactive hormones. Peak LBNP induced similar reductions in mean arterial pressure in both groups. The reduction in leg arterial pulse volume (measured by impedance rheography), an index of peripheral vascular constriction, from baseline to peak LBNP was greater (P<0.05) in the HT group (-0.041 +/- 0.005 ml 100 ml-1) compared to the reduction in the LT group (-0. 025 +/- 0.003 ml 100 ml-1). Greater peak LBNP in the HT group was associated with higher (P<0.05) average elevations in plasma concentrations of vasopressin (pVP, Delta=+7.2 +/- 2.0 pg ml-1) and plasma renin-angiotensin (PRA, Delta=+2.9 +/- 1.3 ng Ang II ml-1 h-1) compared to average elevations of pVP (+2.2 +/- 1.0 pg ml-1) and PRA (+0.1 +/- 0.1 ng Ang II ml-1 h-1) in the LT group. Plasma noradrenaline concentrations were increased (P<0.05) from baseline to peak LBNP in both HT and LT groups, with no statistically distinguishable difference between groups. These data suggest that the renin-angiotensin and vasopressin systems may contribute to sustaining arterial pressure and orthostatic tolerance by their vasoconstrictive actions.
Spectroscopic analysis technique for arc-welding process control
NASA Astrophysics Data System (ADS)
Mirapeix, Jesús; Cobo, Adolfo; Conde, Olga; Quintela, María Ángeles; López-Higuera, José-Miguel
2005-09-01
The spectroscopic analysis of the light emitted by thermal plasmas has found many applications, from chemical analysis to monitoring and control of industrial processes. Particularly, it has been demonstrated that the analysis of the thermal plasma generated during arc or laser welding can supply information about the process and, thus, about the quality of the weld. In some critical applications (e.g. the aerospace sector), an early, real-time detection of defects in the weld seam (oxidation, porosity, lack of penetration, ...) is highly desirable as it can reduce expensive non-destructive testing (NDT). Among others techniques, full spectroscopic analysis of the plasma emission is known to offer rich information about the process itself, but it is also very demanding in terms of real-time implementations. In this paper, we proposed a technique for the analysis of the plasma emission spectrum that is able to detect, in real-time, changes in the process parameters that could lead to the formation of defects in the weld seam. It is based on the estimation of the electronic temperature of the plasma through the analysis of the emission peaks from multiple atomic species. Unlike traditional techniques, which usually involve peak fitting to Voigt functions using the Levenberg-Marquardt recursive method, we employ the LPO (Linear Phase Operator) sub-pixel algorithm to accurately estimate the central wavelength of the peaks (allowing an automatic identification of each atomic species) and cubic-spline interpolation of the noisy data to obtain the intensity and width of the peaks. Experimental tests on TIG-welding using fiber-optic capture of light and a low-cost CCD-based spectrometer, show that some typical defects can be easily detected and identified with this technique, whose typical processing time for multiple peak analysis is less than 20msec. running in a conventional PC.
Hetzel, Terence; Blaesing, Christina; Jaeger, Martin; Teutenberg, Thorsten; Schmidt, Torsten C
2017-02-17
The performance of micro-liquid chromatography columns with an inner diameter of 0.3mm was investigated on a dedicated micro-LC system for gradient elution. Core-shell as well as fully porous particle packed columns were compared on the basis of peak capacity and gradient kinetic plot limits. The results for peak capacity showed the superior performance of columns packed with sub-2μm fully porous particles compared to 3.0μm fully porous and 2.7μm core-shell particles within a range of different gradient time to column void time ratios. For ultra-fast chromatography a maximum peak capacity of 16 can be obtained using a 30s gradient for the sub-2μm fully porous particle packed column. A maximum peak capacity of 121 can be achieved using a 5min gradient. In addition, the influence of an alternative detector cell on the basis of optical waveguide technology and contributing less to system variance was investigated showing an increased peak capacity for all applied gradient time/column void time ratios. Finally, the influence of pressure was evaluated indicating increased peak capacity for maximum performance whereas a limited benefit for ultra-fast chromatography with gradient times below 30s was observed. Copyright © 2017 Elsevier B.V. All rights reserved.
Goldstein, David S; Kopin, Irwin J; Sharabi, Yehonatan; Holmes, Courtney
2015-02-01
Parkinson disease with orthostatic hypotension (PD + OH) and the parkinsonian form of multiple system atrophy (MSA-P) can be difficult to distinguish clinically. Recent studies indicate that PD entails a vesicular storage defect in catecholaminergic neurons. Although cardiac sympathetic neuroimaging by (18)F-dopamine positron emission tomography can identify decreased vesicular storage, this testing is not generally available. We assessed whether plasma biomarkers of a vesicular storage defect can separate PD + OH from MSA-P. We conceptualized that after F-dopamine injection, augmented production of F-dihydroxyphenylacetic acid (F-DOPAC) indicates decreased vesicular storage, and we therefore predicted that arterial plasma F-DOPAC would be elevated in PD + OH but not in MSA-P. We measured arterial plasma F-DOPAC after (18)F-dopamine administration (infused i.v. over 3 min) in patients with PD + OH (N = 12) or MSA-P (N = 21) and in healthy control subjects (N = 26). Peak F-DOPAC:dihydroxyphenylglycol (DHPG) was also calculated to adjust for effects of denervation on F-DOPAC production. Plasma F-DOPAC accumulated rapidly after initiation of (18)F-dopamine infusion. Peak F-DOPAC (5-10 min) in PD + OH averaged three times that in MSA-P (P < 0.0001). Among MSA-P patients, none had peak F-DOPAC > 300 nCi-kg/cc-mCi, in contrast with 7 of 12 PD + OH patients (χ(2) = 16.6, P < 0.0001). DHPG was lower in PD + OH (3.83 ± 0.36 nmol/L) than in MSA-P (5.20 ± 0.29 nmol/L, P = 0.007). All MSA-P patients had peak F-DOPAC:DHPG < 60, in contrast with 9 of 12 PD + OH patients (χ(2) = 17.5, P < 0.0001). Adjustment of peak F-DOPAC for DHPG increased test sensitivity from 58 to 81% at similar high specificity. After F-dopamine injection, plasma F-DOPAC and F-DOPAC:DHPG distinguish PD + OH from MSA-P.
Feasibility of Juno radio occultations of the Io plasma torus
NASA Astrophysics Data System (ADS)
Phipps, P. H.; Withers, P.
2016-12-01
Jupiter's magnetosphere is driven by internally produced plasma. The innermost Galilean satellite, Io, isthe dominant source of this plasma. Volcanoes on Io's surface create an atmosphere of sulfur and oxygenwhich escapes into Jupiter's magnetosphere and becomes ionized. This ionized material is trapped byJupiter's magnetic field and creates a torus of plasma centered at Io's orbital radius, called the Io plasmatorus. This torus is divided into three regions distinct in both density and composition. Densities in thistorus can be probed by spacecraft via radio occultations. A radio occultation occurs when plasma comesbetween a spacecraft and a receiver during a time when the spacecraft is sending a radio signal. The Junospacecraft, which arrived in orbit around Jupiter in July 2016, is in an orbit which will be ideal forperforming radio occultations of the Io plasma torus. We test the feasibility of using thetelecommunications system on the Juno spacecraft to perform a radio occultation. Io plasma torusdensities derived from Voyager 1 data are used in creating a model torus. Using the Ka and X-band radiofrequencies we derive vertical profiles for the total electron content of the modeled Io plasma torus. AMarkov Chain Monte Carlo fit is performed on the derived profiles to extract, for each of the torusregions, the scale height and peak total electron content. The scale height can be used to derive atemperature for the torus while the peak total electron content can be used to derive the peak electrondensity. We show that Juno radio occultation measurements of the Io plasma torus are feasible andscientifically valuable.
Spectroscopic investigation of species separation in opening switch plasmas
NASA Astrophysics Data System (ADS)
Jackson, S. L.; Phipps, D. G.; Richardson, A. S.; Commisso, R. J.; Hinshelwood, D. D.; Murphy, D. P.; Schumer, J. W.; Weber, B. V.; Boyer, C. N.; Doron, R.; Biswas, S.; Maron, Y.
2015-11-01
Interactions between magnetic fields and current-carrying plasmas that lead to the separation of plasma species in multi-species plasmas are being studied in a plasma opening switch geometry. Several Marshall guns are used to inject single or multi-species plasmas between coaxial conductors connected to the output of the Naval Research Laboratory's Hawk pulsed-power generator. Following injection of the plasma, the generator is used at roughly half power to apply an electrical pulse with a peak current of 450 kA, a peak voltage of 400 kV, and a rise time of 1.2 μs. The resulting magnetic field interacts with the plasma through a combination of field penetration and magnetohydrodynamic (MHD) pushing that is not well understood but can lead to the separation of plasma species in multi-species plasmas. An ICCD-coupled spectrometer has been used in combination with magnetic probes, a ribbon-beam interferometer, and particle-in-cell (PIC) modeling to diagnose and understand conditions in the plasma from the time it is injected until the end of the conduction phase of the opening switch. This work supported by the Naval Research Laboratory Base Program and the Office of Naval Research.
Fu, Hai-Yan; Guo, Jun-Wei; Yu, Yong-Jie; Li, He-Dong; Cui, Hua-Peng; Liu, Ping-Ping; Wang, Bing; Wang, Sheng; Lu, Peng
2016-06-24
Peak detection is a critical step in chromatographic data analysis. In the present work, we developed a multi-scale Gaussian smoothing-based strategy for accurate peak extraction. The strategy consisted of three stages: background drift correction, peak detection, and peak filtration. Background drift correction was implemented using a moving window strategy. The new peak detection method is a variant of the system used by the well-known MassSpecWavelet, i.e., chromatographic peaks are found at local maximum values under various smoothing window scales. Therefore, peaks can be detected through the ridge lines of maximum values under these window scales, and signals that are monotonously increased/decreased around the peak position could be treated as part of the peak. Instrumental noise was estimated after peak elimination, and a peak filtration strategy was performed to remove peaks with signal-to-noise ratios smaller than 3. The performance of our method was evaluated using two complex datasets. These datasets include essential oil samples for quality control obtained from gas chromatography and tobacco plant samples for metabolic profiling analysis obtained from gas chromatography coupled with mass spectrometry. Results confirmed the reasonability of the developed method. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Gautam, Ghaneshwar; Surmick, David M.; Parigger, Christian G.
2015-07-01
In this letter, we present a brief comment regarding the recently published paper by Ivković et al., J Quant Spectrosc Radiat Transf 2015;154:1-8. Reference is made to previous experimental results to indicate that self absorption must have occurred; however, when carefully considering error propagation, both widths and peak-separation predict electron densities within the error margins. Yet the diagnosis method and the presented details on the use of the hydrogen beta peak separation are viewed as a welcomed contribution in studies of laser-induced plasma.
Collateral Damage to Satellites from an EMP Attack
2010-08-01
peak dose is computed in an infinite half plane of silicon. The resulting in- plane stresses in silicon are shown in Figure VI.23. In- plane refers to...achieved by the SLAR coating 81 Figure VIII.6. Ratio of the peak in- plane compressive stress to the maximum compressive stress for the SLAR coating...82 Figure VIII.7. Maximum in- plane compressive stress in a SLAR coating on DMSP/NOAA subjected to the threat events 83 Figure VIII.8. Maximum in
Preliminary investigation of high power microwave plasmas for electrothermal thruster use
NASA Technical Reports Server (NTRS)
Power, John L.; Sullivan, Daniel J.
1993-01-01
Results are reported from preliminary tests to evaluate the high power microwave electrothermal thruster (MET) concept, which employs a free-floating plasma discharge maintained by applied CW microwave power to heat a propellant gas flow. Stable plasmas have been created and maintained in helium (He), nitrogen (N2), and hydrogen (H2) as propellants in both the TM(sub 011) and TM(sub 012) modes at discharge pressures from 10 Pa to 69 kPa. Reproducible starting conditions of pressure and power have been documented for all the plasmas. Vortical inflow of the propellant gas was observed to cause the formation of on-axis 'spike' plasmas. The formation and unformation conditions of these plasmas were studied. Operation in the spike plasma condition enables maximum power absorption with minimum wall heating and offers maximum efficiency in heating the propellant gas. In the spike condition, plasmas of the three propellant gases were investigated in an open channel configuration to a maximum applied power level of 11.2 kW (in N2). Microwave power coupling efficiencies of over 90 percent were routinely obtained at absorbed power levels up to 2 kW. Magnetic nozzle effects were investigated with a superconducting solenoid Al magnet applying a high magnetic field to the plasmas in and exiting from the discharge tube.
NASA Technical Reports Server (NTRS)
Stone, N. H.
1981-01-01
An experimental investigation of the disturbed flow field created by conducting bodies in a mesosonic, collisionless plasma stream is reported. The mid-wake region is investigated, where, for bodies of the order of a Debye length in size, the focused ion streams converge to form a significant current density peak on the wake axis. A parametric description is obtained of the behavior of the amplitude, width, and position of this peak. The results also indicate that portions of the axial ion peak are created by additional mechanisms and that body geometry affects the mid-wake structure only when the sheath is sufficiently thin to conform to the shape of the body.
Measurements of ion stopping around the Bragg peak in high-energy-density plasmas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frenje, J. A.; Grabowski, P. E.; Li, C. K.
2015-11-09
For the first time, quantitative measurements of ion stopping at energies about the Bragg peak (or peak ion stopping, which occurs at an ion velocity comparable to the average thermal electron velocity), and its dependence on electron temperature (T e) and electron number density (n e) in the range of 0.5 – 4.0 keV and 3 × 10 22 – 3 × 10 23 cm -3 have been conducted, respectively. It is experimentally demonstrated that the position and amplitude of the Bragg peak varies strongly with T e with n e. As a result, the importance of including quantum diffractionmore » is also demonstrated in the stopping-power modeling of High-Energy-Density Plasmas.« less
NASA Astrophysics Data System (ADS)
Marr, M.; Kuhn, J.; Metcalfe, C.; Harris, J.; Kesler, O.
2014-01-01
Yttria-stabilized zirconia (YSZ) electrolytes were deposited by suspension plasma spraying (SPS) and solution precursor plasma spraying (SPPS). The electrolytes were evaluated for permeability, microstructure, and electrochemical performance. With SPS, three different suspensions were tested to explore the influence of powder size distribution and liquid properties. Electrolytes made from suspensions of a powder with d50 = 2.6 μm were more gas-tight than those made from suspensions of a powder with d50 = 0.6 μm. A peak open circuit voltage of 1.00 V was measured at 750 °C with a cell with an electrolyte made from a suspension of d50 = 2.6 μm powder. The use of a flammable suspension liquid was beneficial for improving electrolyte conductivity when using lower energy plasmas, but the choice of liquid was less important when using higher energy plasmas. With SPPS, peak electrolyte conductivities were comparable to the peak conductivities of the SPS electrolytes. However, leak rates through the SPPS electrolytes were higher than those through the electrolytes made from suspensions of d50 = 2.6 μm powder. The electrochemical test data on SPPS electrolytes are the first reported in the literature.
Ellefsen, Kayla N; Concheiro, Marta; Pirard, Sandrine; Gorelick, David A; Huestis, Marilyn A
2016-06-01
No controlled cocaine administration data describe cocaine and metabolite disposition in oral fluid (OF) collected with commercially-available collection devices, OF-plasma ratios, and pharmacodynamic relationships with plasma and OF cocaine and metabolite concentrations. Eleven healthy, cocaine-using adults received 25mg intravenous cocaine. Physiological and subjective effects (visual analogue scales), and plasma were collected one hour prior, and up to 21h post-dose. OF was collected with the Quantisal™ device up to 69h post-dose. Cocaine, benzoylecgonine (BE) and ecgonine methyl ester were quantified in plasma by liquid chromatography-tandem mass spectrometry; cocaine and BE were quantified in OF by two dimensional-gas chromatography-mass spectrometry. Increases in heart rate, blood pressure and positive subjective effects occurred within the first 15min, persisting up to 1h ("Rush"), with clockwise hysteresis observed for plasma and OF concentrations and some subjective measures. Peak subjective effects ("Rush," "Good drug effect" and "Bad drug effect") occurred prior to peak OF cocaine concentration, whereas observed peak plasma concentrations and subjective measures occurred simultaneously, most likely due to significantly earlier plasma Tmax compared to OF Tmax.Tlast was generally longer in OF (12.5h cocaine; 33.0h BE) than plasma (9.5h cocaine; >21h BE, cutoffs 1μg/L); 8 and 10μg/L OF cocaine confirmatory cutoffs yielded detection times similar to cocaine's impairing effects, suggesting usefulness for DUID testing. OF offers advantages as an alternative matrix to blood and plasma for identifying cocaine intake, defining pharmacokinetic parameters at different confirmation cutoffs, and aiding different drug testing programs to best achieve their monitoring goals. Copyright © 2016. Published by Elsevier Ireland Ltd.
NASA Astrophysics Data System (ADS)
Tanışlı, Murat; Taşal, Erol
2017-06-01
Atmospheric-pressure low-temperature plasma jets and their applications are a topic of great interest in the fields of physics, technology, and medicine. In this study, the used self-made plasma jet is based on a dielectric barrier discharge (DBD) in neon (Ne) with typical processing parameters, such as frequency in the kHz range and voltage in the kV range. The plasma is characterized by optical emission spectroscopy (OES). These types of plasma can be used in various applications such as surface modification, inactivation of microorganisms, and chemical decomposition. This study is concerned with the Fourier transform infrared spectrum (FT-IR) and ultraviolet-visible (UV-vis) absorption spectroscopy of the large 7-acetoxy-6-(2,3-dibromopropyl)-4,8-dimethylcoumarin molecule (abbreviated as 7AC) dissolved in ethanol and methanol solvents and their modification after atmospheric-pressure plasma treatment (APPT) with the DBD. The research is motivated by the significance of this molecule in different fields of application. Also the changes in the structure are recorded. After APPT, the peak corresponding to the carbonyl bond at a wavenumber of 1715 cm-1 disappears in the IR spectrum of the ethanol solution, and when splitting at a wavenumber of 1405 cm-1 is observed, the peak at 1224 cm-1 is found to disappear after plasma is applied. It is seen new peaks at frequencies of 432 and 655 cm-1 are formed. When the same situation is analyzed for the 7AC molecule dissolved in methanol, a new peak is observed at 1634 cm-1. The intensities of the peaks at 3433 and 2075 cm-1 also increase and there is a large change in the wavenumber at 600 cm-1. In the UV spectra, a significant increase in the absorbance of the 7AC molecule dissolved in ethanol is observed after APPT, whereas a small decrease in the absorbance of the 7AC molecule dissolved in methanol is obtained. Owing to the lack of symmetry, many normal bands of vibrations are mixed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Remya, B.; Reddy, R. V.; Lakhina, G. S.
2014-09-20
During 1999 August 18, both Cassini and WIND were in the Earth's magnetosheath and detected transverse electromagnetic waves instead of the more typical mirror-mode emissions. The Cassini wave amplitudes were as large as ∼14 nT (peak to peak) in a ∼55 nT ambient magnetic field B {sub 0}. A new method of analysis is applied to study these waves. The general wave characteristics found were as follows. They were left-hand polarized and had frequencies in the spacecraft frame (f {sub scf}) below the proton cyclotron frequency (f{sub p} ). Waves that were either right-hand polarized or had f {sub scf}more » > f{sub p} are shown to be consistent with Doppler-shifted left-hand waves with frequencies in the plasma frame f{sub pf} < f{sub p} . Thus, almost all waves studied are consistent with their being electromagnetic proton cyclotron waves. Most of the waves (∼55%) were found to be propagating along B {sub 0} (θ{sub kB{sub 0}}<30{sup ∘}), as expected from theory. However, a significant fraction of the waves were found to be propagating oblique to B {sub 0}. These waves were also circularly polarized. This feature and the compressive ([B {sub max} – B {sub min}]/B {sub max}, where B {sub max} and B {sub min} are the maximum and minimum field magnitudes) nature (ranging from 0.27 to 1.0) of the waves are noted but not well understood at this time. The proton cyclotron waves were shown to be quasi-coherent, theoretically allowing for rapid pitch-angle transport of resonant protons. Because Cassini traversed the entire subsolar magnetosheath and WIND was in the dusk-side flank of the magnetosheath, it is surmised that the entire region was filled with these waves. In agreement with past theory, it was the exceptionally low plasma β (0.35) that led to the dominance of the proton cyclotron wave generation during this interval. A high-speed solar wind stream ((V{sub sw} ) = 598 km s{sup –1}) was the source of this low-β plasma.« less
Evidence for Particle Inward Transport, Theoretical prediction and Importance for Reacting Plasmas
NASA Astrophysics Data System (ADS)
Sharky, N.; Coppi, B.; Mazzotta, C.
2017-10-01
The fact that particle transport cannot be described by a diffusion equation but by one that would include an inflow term, involving transport in the direction of the density gradient, was evidenced by experiments on magnetically confined plasmas in which the central plasma density was observed to increase as a result of gas injection at the edge of the plasma column. The validity of the proposed equation has been repeatedly confirmed over the years and limitations for the occurrence of particle inflow in a variety of experimental conditions have been uncovered. The direct experimental observation of the inward propagating particle cloud leading to a profile peaking is described and the effects of different degrees of density peaking in fusion burning plasmas are analyzed. Sponsored in part by the U.S. DoE.
Effect of σ2 on All Aspects of Failure in Rocks from Granite to Sandstone
NASA Astrophysics Data System (ADS)
Haimson, B. C.; Ma, X.
2014-12-01
We have studied the effect of σ2 on failure characteristics of two crystalline and three clastic rocks subjected to true triaxial stresses. Common to all rocks tested is the rise in both strain localization onset and σ1 at failure (σ1,peak) for a given σ3, as σ2 is elevated beyond its base level (σ2 = σ3). σ1,peak reaches a maximum at some level of σ2, beyond which it gradually declines, approaching its base magnitude when σ2 nears its own maximum. Failure-plane angle with respect to σ1 for a given σ3 also increases with σ2, at least until the maximum σ1,peak is reached. Westerly granite (Haimson and Chang, IJRMMS, 2000) and KTB amphibolite (Chang and Haimson, JGR, 2000), exhibited a dramatic σ2 effect: at low σ3 (20-30 MPa), higher σ2 lifted σ1,peak by up to 50% over its base level. At high σ3, the increase in σ1,peak was reduced, but even at σ3 = 100 MPa, maximum σ1,peak in both rocks was over 20% higher than its base level. Failure mode remained brittle throughout the stress range tested, but the onset of dilatancy rose with σ2, as did the failure-plane (shear-band) angle (by up to 20°). A gentler effect of σ2 on σ1, peak and failure-plane angle was observed in the clastics, and that effect subsided as porosity increased. In low porosity (φ = 7%) TCDP siltstone (Oku, et al, GRL, 2007), the maximum σ1,peak at σ3 = 25 MPa was about 30% larger than at σ2 = σ3 level, and only 12.5% larger at σ3 = 100 MPa. Failure mode stayed brittle throughout, but shear-band angle increase with σ2 was limited to about 10°, irrespective of σ3 level. An even smaller σ2 effect was observed in Coconino sandstone (φ = 17%) (Ma, PhD thesis, 2014). σ1,peak reached a maximum of about 10% higher than at σ2 = σ3 level; failure-plane angle rise with σ2 was less than 10°. The weakest σ2 effect was found in the high porosity (φ= 25%) Bentheim sandstone (Ma, PhD thesis, 2014). Here σ1, peak reached a maximum of well under 10% higher than its base magnitude, regardless of σ3 level; average failure-plane angle rise with σ2 was below 10°. Failure at σ3 = 150 MPa was along a compaction band(s) normal to σ1, regardless of σ2. Both Coconino and Bentheim underwent dilatant failure at low σ3, shifting to compactive failure at high σ3 levels. But σ2 also affected the failure mode: compactive failure at σ2 = σ3 gradually reverted to a dilatant mode as σ2 was raised.
Tahboub, Yahya R
2014-12-01
Chromatographic behavior of co-eluted compounds from un-extracted drug-free plasma samples was studied by LC-MS and LC-MS/MS with positive APCI. Under soft gradient, total ion chromatogram (TIC) consisted of two major peaks separated by a constant lower intensity region. Early peak (0.15-0.4 min) belongs to polar plasma compounds and consisted of smaller mass ions ( m / z <250); late peak (3.6-4.6 min) belongs to thermally unstable phospholipids and consisted of fragments with m / z <300. Late peak is more sensitive to variations in chromatographic and MS parameters. Screening of most targeted cardiovascular drugs at levels lower than 50 ng/mL has been possible by LC-MS for drugs with retention factors larger than three. Matrix effects and recovery, at 20 and 200 ng/mL, were evaluated for spiked plasma samples with 15 cardiovascular drugs, by MRM-LC-MS/MS. Average recoveries were above 90% and matrix effects expressed as percent matrix factor (% MF) were above 100%, indicating enhancement character for APCI. Large uncertainties were significant for drugs with smaller masses ( m / z <250) and retention factors lower than two.
Bruch, Brittany A; Singh, Sachinkumar B; Ramsey, Laura J; Starner, Timothy D
2018-05-01
This study was undertaken to determine if a clinically relevant drug-drug interaction occurred between ibuprofen and lumacaftor/ivacaftor. Peak ibuprofen plasma concentrations were measured prior to and after lumacaftor/ivacaftor initiation. A Wilcoxon signed rank sum test was used to compare the values. Nine patients were included in the final analysis. Peak ibuprofen plasma concentrations decreased an average of 36.4 mcg/mL after initiation of lumacaftor/ivacaftor with a relative reduction of 41.7%. The average peak plasma concentration was 84.2 mcg/mL (SD = 10.9) prior to lumacaftor/ivacaftor initiation and 47.9 mcg/mL (SD = 16.4) following initiation (P = 0.0039). Peak concentrations occurred at an average of 100 min (SD = 30) and 107 min (SD = 40) prior to and following lumacaftor/ivacaftor initiation, respectively. We suggest a clinically relevant drug-drug interaction exists between ibuprofen and lumacaftor/ivacaftor. Lumacaftor may cause subtherapeutic ibuprofen plasma concentrations due to the induction of CYP enzymes and increased metabolism of ibuprofen. Based on this analysis, we have modified our use of ibuprofen in several patients after evaluation of this drug-drug interaction. © 2018 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Yadav, Sonu; Ghosh, Soumen; Bose, Sayak; Barada, Kshitish K.; Pal, Rabindranath; Chattopadhyay, Prabal K.
2018-04-01
Experimentally, the density profile in the magnetic nozzle of a helicon antenna based plasma device is seen to be modified from being centrally peaked to that of hollow nature as the external magnetic field is increased. It occurs above a characteristic field value when the ions become magnetized in the expansion chamber. The density profile in the source chamber behind the nozzle, however, remains peaked on-axis irrespective of the magnetic field. The electron temperature there is observed to be hollow and this nature is carried to the expansion chamber along the field line. In the electron energy distribution near the off axis peak location, a high energy tail exists. Rotation of these tail electrons in the azimuthal direction due to the gradient-B drift in the expansion chamber leads to an additional off-axis ionization and forms the hollow density profile. It seems that if the ions are not magnetized, then the off-axially produced additional plasma is not confined and the density profile retains the on-axis peak nature. The present experiment successfully demonstrates how the knowledge of the ion magnetization together with tail electrons significantly contributes to the design of an efficient helicon plasma based thruster.
Ghigiarelli, Jamie J; Pelton, Luke M; Gonzalez, Adam M; Fulop, Andras M; Gee, Joshua Y; Sell, Katie M
2018-04-01
Ghigiarelli, JJ, Pelton, LM, Gonzalez, AM, Fulop, AM, Gee, JY, and Sell, KM. Effects of a 6-week bench press program using the freak bar in a sample of collegiate club powerlifters. J Strength Cond Res 32(4): 938-949, 2018-Powerlifters train using specialty bars for unstable load (UL) training. For the bench press, the acute effects of UL are mixed, with few studies that examine training interventions. The purpose of this study was to examine the effects of a 6-week bench press training program that uses the Freak Bar (FB) as compared to a traditional barbell (TB) on maximum bench press, peak force, and peak impulse. Seven men and 3 women (21 ± 2.0 years, 172.2 ± 2.9 cm, and 95.3 ± 20.3 kg) were required to bench press 2 days per week as part of a structured program. On the second bench press day, the FB and TB groups performed 3-position pause bench presses at 60-70% one repetition maximum (1RM). One repetition maximum, peak force, and peak impulse were measured before test and after test after the 6-week program. Peak force and peak impulse were tested at 3 bench positions, including the presticking, sticking, and poststicking points, defined by the distance of the barbell from the chest. Posttraining 1RM for the FB group and TB group increased 6.7% (6.78 ± 1.6 kg, p = 0.006) and 4.3% (4.5 ± 2.7 kg, p = 0.23), respectively, with no significant differences between the groups (p = 0.589, ηp = 0.044). There were no significant differences between the groups at each bench position for peak force (p = 0.606) or peak impulse (p = 0.542). Freak Bar can be an alternative for improving maximum strength and peak force but is not significantly better than TB training when performing the 3-position pause bench press.
McKenzie, Erica C; Esser, Melissa M; McNitt, Sarah E; Payton, Mark E
2016-07-01
OBJECTIVE To compare the effects of equivalent volumes of equine plasma and 6% hydroxyethyl starch (600/0.75) solution (hetastarch) administered IV on plasma colloid osmotic pressure (pCOP) and commonly monitored clinicopathologic variables in horses. ANIMALS 6 healthy mares. PROCEDURES In a randomized, crossover study, horses were administered hetastarch or plasma (both 10 mL/kg, IV) 18 months apart. The pCOP and variables of interest were measured before (baseline), immediately after, and at intervals up to 96 or 120 hours after infusion. Prothrombin and activated partial thromboplastin times were measured before and at 2 and 8 hours after each infusion. RESULTS Prior to hetastarch and plasma infusions, mean ± SEM pCOP was 19.4 ± 0.5 mm Hg and 19.4 ± 0.8 mm Hg, respectively. In general, hetastarch and plasma infusions comparably increased pCOP from baseline for 48 hours, with maximum increases of 2.0 and 2.3 mm Hg, respectively. Mean Hct and hemoglobin, total protein, and albumin concentrations were decreased for a period of 72, 96, or 120 hours after hetastarch infusion with maximum decrements of 8.8%, 3.2 g/dL, 1.2 g/dL, and 0.6 g/dL, respectively. Plasma infusion decreased (albeit not always significantly) hemoglobin concentration and Hct for 20 and 24 hours (maximum changes of 1.5 g/dL and 6.6%, respectively) and increased total solids concentration (maximum change of 0.6 g/dL) for 48 hours. Platelet count and coagulation times were minimally affected. CONCLUSIONS AND CLINICAL RELEVANCE Overall, the hetastarch and plasma infusions comparably increased pCOP in healthy horses for up to 48 hours. Hetastarch induced greater, more persistent perturbations in clinicopathologic variables.
Carbon dioxide dissociation in non-thermal radiofrequency and microwave plasma
NASA Astrophysics Data System (ADS)
Huang, Qiang; Zhang, Diyu; Wang, Dongping; Liu, Kezhao; Kleyn, Aart W.
2017-07-01
We have studied carbon dioxide dissociation in inductively coupled radiofrequency plasma and microwave plasma at low gas pressure. Both systems exhibit features of non-thermal plasma. The highest energy efficiency observed is 59.3% (2.13 mmol kJ-1), exceeding the maximum value of about 45% in case of thermodynamic equilibrium, and a maximum conversion of 80.6% is achieved. Different discharge conditions, such as the source frequency, discharge gas pressure and the addition of argon, will affect the plasma parameters, especially the electron energy distribution. This plays a great role in the energy transfer from non-thermal plasma to the molecular dissociation reaction channel by enabling the ladder climbing of the carbon dioxide molecular vibration. The results indicate the importance of ladder climbing.
Development of high energy pulsed plasma simulator for plasma-lithium trench experiment
NASA Astrophysics Data System (ADS)
Jung, Soonwook
To simulate detrimental events in a tokamak and provide a test-stand for a liquid lithium infused trench (LiMIT) device, a pulsed plasma source utilizing a theta pinch in conjunction with a coaxial plasma accelerator has been developed. An overall objective of the project is to develop a compact device that can produce 100 MW/m2 to 1 GW/m2 of plasma heat flux (a typical heat flux level in a major fusion device) in ~ 100 mus (≤ 0.1 MJ/m2) for a liquid lithium plasma facing component research. The existing theta pinch device, DEVeX, was built and operated for study on lithium vapor shielding effect. However, a typical plasma energy of 3 - 4 kJ/m2 is too low to study an interaction of plasma and plasma facing components in fusion devices. No or little preionized plasma, ringing of magnetic field, collisions of high energy particles with background gas have been reported as the main issues. Therefore, DEVeX is reconfigured to mitigate these issues. The new device is mainly composed of a plasma gun for a preionization source, a theta pinch for heating, and guiding magnets for a better plasma transportation. Each component will be driven by capacitor banks and controlled by high voltage / current switches. Several diagnostics including triple Langmuir probe, calorimeter, optical emission measurement, Rogowski coil, flux loop, and fast ionization gauge are used to characterize the new device. A coaxial plasma gun is manufactured and installed in the previous theta pinch chamber. The plasma gun is equipped with 500 uF capacitor and a gas puff valve. The increase of the plasma velocity with the plasma gun capacitor voltage is consistent with the theoretical predictions and the velocity is located between the snowplow model and the weak - coupling limit. Plasma energies measured with the calorimeter ranges from 0.02 - 0.065 MJ/m2 and increases with the voltage at the capacitor bank. A cross-check between the plasma energy measured with the calorimeter and the triple probe / optics shows that the plasma energies are in agreement with each other. The effect of theta pinch on preionized plasma has been investigated when operated in conjunction with the coaxial plasma gun. The previous theta coil (1 turn, 40 nH) is connected with 72 muF capacitor bank to handle more energy. The theta coil is reconfigured as a two - turn coil (160 nH) to facilitate the operation of a crowbar. The two-turn coil achieves a maximum current of 300 kA (= 1.2 T) at 20 kV of the main capacitor bank voltage and the operation of the crowbar allows for a monotonically decreasing current. With the 2-turn theta coil, a maximum plasma energy of ~ 0.08 MJ/m2 is achieved with 6 kV at the plasma gun and 20 kV at the theta pinch. Plasma velocities of 34 - 74 km/s are observed at the first few peaks of theta pinch current. A problem of plasma transport with short delay times is observed. Finally, the dissertation concludes with a few ways to further improve the device and increase the plasma heat flux. A change in the system design as well as a compact toroid generation are proposed and preliminary results are presented. The dissertation also suggests hardware upgrades which include an increase in the energy at the plasma gun / the theta pinch capacitor banks. At the same time, additional diagnostics will allow to further investigate the effect of pinching on the plasma from the plasma gun as well as determine the overall effect of the guiding magnetic field. (Abstract shortened by UMI.).
Parsimonious Charge Deconvolution for Native Mass Spectrometry
2018-01-01
Charge deconvolution infers the mass from mass over charge (m/z) measurements in electrospray ionization mass spectra. When applied over a wide input m/z or broad target mass range, charge-deconvolution algorithms can produce artifacts, such as false masses at one-half or one-third of the correct mass. Indeed, a maximum entropy term in the objective function of MaxEnt, the most commonly used charge deconvolution algorithm, favors a deconvolved spectrum with many peaks over one with fewer peaks. Here we describe a new “parsimonious” charge deconvolution algorithm that produces fewer artifacts. The algorithm is especially well-suited to high-resolution native mass spectrometry of intact glycoproteins and protein complexes. Deconvolution of native mass spectra poses special challenges due to salt and small molecule adducts, multimers, wide mass ranges, and fewer and lower charge states. We demonstrate the performance of the new deconvolution algorithm on a range of samples. On the heavily glycosylated plasma properdin glycoprotein, the new algorithm could deconvolve monomer and dimer simultaneously and, when focused on the m/z range of the monomer, gave accurate and interpretable masses for glycoforms that had previously been analyzed manually using m/z peaks rather than deconvolved masses. On therapeutic antibodies, the new algorithm facilitated the analysis of extensions, truncations, and Fab glycosylation. The algorithm facilitates the use of native mass spectrometry for the qualitative and quantitative analysis of protein and protein assemblies. PMID:29376659
Temporal and spatial deviation in F2 peak parameters derived from FORMOSAT-3/COSMIC
NASA Astrophysics Data System (ADS)
Kumar, Sanjay; Singh, R. P.; Tan, Eng Leong; Singh, A. K.; Ghodpage, R. N.; Siingh, Devendraa
2016-06-01
The plasma frequency profiles derived from the Constellation of Observing System for Meteorology, Ionosphere and Climate (COSMIC) radio occultation measurements are compared with ground-based ionosonde data during the year 2013. Equatorial and midlatitude five stations located in the Northern and Southern Hemisphere are considered: Jicamarca, Jeju, Darwin, Learmonth, and Juliusruh. The aim is to validate the COSMIC-derived data with ground-based measurements and to estimate the difference in plasma frequency (which represents electron density) and height of F2 layer peak during the daytime/nighttime and during different seasons by comparing the two data sets. Analysis showed that the nighttime data are better correlated than the daytime, and the maximum difference occurs at the equatorial ionospheric anomaly (EIA) station as compared to lower and midlatitude stations during the equinox months. The difference between daytime and nighttime correlations becomes insignificant at midlatitude stations. The statistical analysis of computed errors in foF2 (hmF2) showed Gaussian nature with the most probable error range of ±15% (±10%) at the equatorial and EIA stations, ±9% (±7%) outside the EIA region which reduced to ±8% (±6%) at midlatitude stations. The reduction in error at midlatitudes is attributed to the decrease in latitudinal electron density gradients. Comparing the analyzed data during the three geomagnetic storms and quiet days of the same months, it is observed that the differences are significantly enhanced during storm periods and the magnitude of difference in foF2 increases with the intensity of geomagnetic storm.
NASA Astrophysics Data System (ADS)
Kostin, V. M.; Belyaev, G. G.; Boichev, B.; Trushkina, E. P.; Ovcharenko, O. Ya.
2015-03-01
The ionospheric parameters were analyzed, which made it possible to distinguish several successive stages in the development of isolated tropical cyclones (TCs). Data were taken from the Cosmos-1809 and Intercosmos Bulgaria-1300 satellites, which passed over several dozen TCs. The first stage of TC development consists of a sharp increase in altitudinal substorm activity caused by a tropical disturbance and depression. During this stage, plasma density caverns extending over several hundreds of kilometers are observed in the nighttime upper ionosphere a day before the formation of a tropical storm or even a category-I hurricane. The second stage, typical of TCs with intensities reaching categories I and II, is the displacement of a wide plasma density maximum in the upper ionosphere from the geomagnetic equator into the region, the center of which along the geomagnetic field line is projected to 200-230 km altitudes at a TC latitude. The third stage, which is typical of TC categories III-V, consists of the formation of an additional Ne peak (with a width reaching 1000 km) near the TC zenith. This peak includes Δ Ne disturbances and is accompanied by electrostatic oscillations at the H+ and He+ cyclotron frequencies and at the lower hybrid resonance frequency and by electric fields that are projected into the magnetically conjugate region. The crossing of New Caledonia by the category-IV TC Harry was considered in detail. It was shown that the neutral particle ascending jet probably deviated along the meridian in this case.
Deng, Li; Li, Yongzhi; Zhang, Xinshi; Chen, Bo; Deng, Yulin; Li, Yujuan
2015-10-10
A UPLC-MS method was developed for determination of pterostilbene (PTS) in plasma and tissues of mice. PTS was separated on Agilent Zorbax XDB-C18 column (50 × 2.1 mm, 1.8 μm) with gradient mobile phase at the flow rate of 0.2 ml/min. The detection was performed by negative ion electrospray ionization in multiple reaction monitoring mode. The linear calibration curve of PTS in mouse plasma and tissues ranged from 1.0 to 5000 and 0.50 to 500 ng/ml (r(2)>0.9979), respectively, with lowest limits of quantification (LLOQ) were between 0.5 and 2.0 ng/ml, respectively. The accuracy and precision of the assay were satisfactory. The validated method was applied to the study of bioavailability and tissue distribution of PTS in normal and Lewis lung carcinoma (LLC) bearing mice. The bioavailability of PTS (dose 14, 28 and 56 mg/kg) in normal mice were 11.9%, 13.9% and 26.4%, respectively; and the maximum level (82.1 ± 14.2 μg/g) was found in stomach (dose 28 mg/kg). The bioavailability, peak concentration (Cmax), time to peak concentration (Tmax) of PTS in LLC mice was increased compared with normal mice. The results indicated the UPLC-MS method is reliable and bioavailability and tissue distribution of PTS in normal and LLC mice were dramatically different. Copyright © 2015 Elsevier B.V. All rights reserved.
Over, Thomas M.; Saito, Riki J.; Veilleux, Andrea G.; Sharpe, Jennifer B.; Soong, David T.; Ishii, Audrey L.
2016-06-28
This report provides two sets of equations for estimating peak discharge quantiles at annual exceedance probabilities (AEPs) of 0.50, 0.20, 0.10, 0.04, 0.02, 0.01, 0.005, and 0.002 (recurrence intervals of 2, 5, 10, 25, 50, 100, 200, and 500 years, respectively) for watersheds in Illinois based on annual maximum peak discharge data from 117 watersheds in and near northeastern Illinois. One set of equations was developed through a temporal analysis with a two-step least squares-quantile regression technique that measures the average effect of changes in the urbanization of the watersheds used in the study. The resulting equations can be used to adjust rural peak discharge quantiles for the effect of urbanization, and in this study the equations also were used to adjust the annual maximum peak discharges from the study watersheds to 2010 urbanization conditions.The other set of equations was developed by a spatial analysis. This analysis used generalized least-squares regression to fit the peak discharge quantiles computed from the urbanization-adjusted annual maximum peak discharges from the study watersheds to drainage-basin characteristics. The peak discharge quantiles were computed by using the Expected Moments Algorithm following the removal of potentially influential low floods defined by a multiple Grubbs-Beck test. To improve the quantile estimates, regional skew coefficients were obtained from a newly developed regional skew model in which the skew increases with the urbanized land use fraction. The drainage-basin characteristics used as explanatory variables in the spatial analysis include drainage area, the fraction of developed land, the fraction of land with poorly drained soils or likely water, and the basin slope estimated as the ratio of the basin relief to basin perimeter.This report also provides the following: (1) examples to illustrate the use of the spatial and urbanization-adjustment equations for estimating peak discharge quantiles at ungaged sites and to improve flood-quantile estimates at and near a gaged site; (2) the urbanization-adjusted annual maximum peak discharges and peak discharge quantile estimates at streamgages from 181 watersheds including the 117 study watersheds and 64 additional watersheds in the study region that were originally considered for use in the study but later deemed to be redundant.The urbanization-adjustment equations, spatial regression equations, and peak discharge quantile estimates developed in this study will be made available in the web application StreamStats, which provides automated regression-equation solutions for user-selected stream locations. Figures and tables comparing the observed and urbanization-adjusted annual maximum peak discharge records by streamgage are provided at https://doi.org/10.3133/sir20165050 for download.
Brusov, O S; Matveev, I A; Kirillov, P S; Faktor, M I; Karpova, N S; Vasilyeva, E F; Katasonov, A B; Zozulya, S A; Klushnik, T P
To assess the risk of thrombotic events in patients with schizophrenia and schizoaffective disorder based on 'fibrinodynamics' technology. A group of 76 women, including 38 with paranoid schizophrenia (F20.0), 18 with schizoaffective disorder (F25.1) in the acute stage, and 20 healthy controls, participated in the study. The technology includes the study of coagulation and fibrinolysis, Karmin author software, and calculation of peak time and hemostasis potential of spontaneous clots. Growth and lysis of fibrin clots were studied in plasma purified from platelets. All preanalytic procedures were conducted within 30 minutes after blood sampling. Blood serum was studied separately using the neuroimmunological test. Dynamic of brightness profiles of the clots was determined and a number of parameters (peak time and hemostasis potential of spontaneous clots) were calculated using the Karmin software. In patients with schizophrenia, the dynamic brightness profile of the clots has two peaks: the first peak is formed as a result of the growth and lysis of the clot initiated by the activator, the second peak is due to the growth and lysis of spontaneous clots in the volume of the measuring cuvette far from the activator. In healthy donors, the second peak under experimental conditions is absent. In the group of schizophrenic patients, a strong negative correlation is observed between the peak time of the second peak and the activity of leukocyte elastase (Spearman R = -0.75, p<0.0001), i.e. the greater the activity of elastase, the earlier the maximum of the second peak is formed and vice versa. In the control group, there is no such correlation. Evaluation of the potential of hemostasis of spontaneous clots showed that in 42% of schizophrenic patients this parameter is shifted above the norm, which indicates an increased risk of thrombosis of small brain arteries in these patients. The developed technology of 'fibrinodynamics' has a good potential for introduction into personalized medicine to identify increased risks of thrombosis of small cerebral vessels in patients with acute schizophrenia leading to the development of cognitive disorders and to control the normalization of hemostasis with antiplatelet or anticoagulant drugs.
Stratford, M. R.; Dennis, M. F.; Hoskin, P.; Phillips, H.; Hodgkiss, R. J.; Rojas, A.
1996-01-01
The effect of inhibiting gastric acid secretion on nicotinamide pharmacokinetics was studied in five volunteers with the intent of reducing the large variations observed previously in the time to and magnitude of peak plasma concentrations. Plasma levels were determined using a standard high-performance liquid chromatography (HPLC) method after an oral dose of 3 g of nicotinamide either alone or preceded by pretreatment with omeprazole. Suppression of gastric acid production had no significant effect on the rate of uptake or on the peak levels achieved. To bypass gastric acidity, the rectal route was also assessed using a suppository in four volunteers and one patient undergoing radiotherapy. Absorption was slow and variable and much lower plasma levels were observed than after oral dosing. Thus, no improvement in the pharmacokinetics of nicotinamide was observed using either of these two approaches. Parallel estimations were made using a novel and non-invasive method for monitoring nicotinamide pharmacokinetics in saliva. A large and variable fraction of the total amount of nicotinamide-related material in saliva was found to be nicotinic acid, a metabolite not normally found in human plasma. This conversion was inhibited by the use of a chlorhexidine mouthwash, indicating that the oral flora was responsible for its production. The time to peak levels of nicotinamide or of nicotinamide plus nicotinic acid in saliva correlated well with that in plasma. However, peak concentrations for nicotinamide alone were significantly lower than in plasma, and very variable, whereas for nicotinamide plus nicotinic acid saliva levels were 20-30% higher, but more consistent. Although there are some practical difficulties in quantitatively handling saliva, the method is very useful for monitoring nicotinamide pharmacokinetics and for assessment of compliance with nicotinamide treatment. PMID:8679452
Takahashi, K; Inoue, K; Takahashi, Y
1976-10-01
Twenty-four-hr patterns of plasma corticosterone levels were determined at 4-hr intervals every 3-4 weeks in sighted and blinded pinealectomized rats of adult age. Through the whole period of the experiment, 24-hr patterns of food intake were also measured weekly. The sighted rats manifested the same 24-hr patterns of plasma corticosterone levels and food intake for 15 weeks after pinealectomy as those observed in the intact control rats. The magnitude of peak levels of plasma corticosterone and the amount of food intake did not differ between the two groups. A phase shift in circadian rhythms of plasma corticosterone levels and food intake was observed in both groups of blinded rats, with and without pinealectomy. Between the two groups, the patterns of phase shift were essentially similar for 10 weeks examined after optic enucleation. The peak elevation of plasma levels took place at 11 p.m. at the end of the 4th week after optic enucleation. Thereafter, 4- to 8-hr delay of peak appearance was observed every 3 weeks. No significant differences were found in peak values between the two groups of blinded rats. Furthermore, the circadian rhythm of food intake shifted in parallel with that of plasma corticosterone levels. A phase reversal of these two activities was observed between the 8th and 10th week after the operation. These results indicate that the pineal gland does not play any important role either in the maintenance of normal circadian periodicities of adrenocortical activity and food intake or in the shift in circadian rhythms of the two activities in the blinded rats.
Plasma l-citrulline concentrations in l-arginine-supplemented healthy dogs.
Flynn, K M; Kellihan, H B; Trepanier, L A
2017-08-01
To determine whether oral l-arginine increases plasma [l-citrulline] in dogs. Eleven healthy staff-owned dogs were used in this study. Dogs (n = 3) were given l-arginine (50mg/kg PO q8h) for 7 days, and plasma [l-arginine] and [l-citrulline] were analyzed by high performance liquid chromatography at baseline (BL), steady state trough, and 0.5, 1, 1.5, 2, 4, 6, and 8 h after final dosing on day 7. Eleven dogs were then treated with 100mg/kg l-arginine PO q8h for 7 days, and [l-arginine] and [l-citrulline] were measured at BL, steady state trough, and at peak 4 hrs after dosing (T4 hrs). - Plasma [l-arginine] and [l-citrulline] peaked at T4 hrs on the 50mg/kg dosage. Target outcome, modeled after human study results, of a doubling of [l-arginine] and a 25-30% increase in [l-citrulline] from BL were not reached. After the 100mg/kg dosage, plasma [l-arginine] increased from a BL median of 160.1 μM (range, 100.2-231.4 μM) to a peak of 417.4 μM (206.5-807.3 μM) at T4 hrs, and plasma [l-citrulline] increased from a BL median of 87.8 μM (59.1-117.1 μM) to peak of 102.2 μM (47.4-192.6 μM) at T4 hrs. Ten of eleven dogs showed a doubling of plasma [l-arginine] and 4/11 dogs achieved 25-30% or greater increases in plasma [l-citrulline]. No adverse effects on heart rate or blood pressure were noted. - Oral l-arginine dosage of 100mg/kg q8h doubles plasma [l-arginine] in healthy dogs, but conversion to l-citrulline is quite variable. Further evaluation of this dosage regimen in dogs with pulmonary hypertension is warranted. Copyright © 2017 Elsevier B.V. All rights reserved.
Gyrokinetic modeling of impurity peaking in JET H-mode plasmas
NASA Astrophysics Data System (ADS)
Manas, P.; Camenen, Y.; Benkadda, S.; Weisen, H.; Angioni, C.; Casson, F. J.; Giroud, C.; Gelfusa, M.; Maslov, M.
2017-06-01
Quantitative comparisons are presented between gyrokinetic simulations and experimental values of the carbon impurity peaking factor in a database of JET H-modes during the carbon wall era. These plasmas feature strong NBI heating and hence high values of toroidal rotation and corresponding gradient. Furthermore, the carbon profiles present particularly interesting shapes for fusion devices, i.e., hollow in the core and peaked near the edge. Dependencies of the experimental carbon peaking factor ( R / L nC ) on plasma parameters are investigated via multilinear regressions. A marked correlation between R / L nC and the normalised toroidal rotation gradient is observed in the core, which suggests an important role of the rotation in establishing hollow carbon profiles. The carbon peaking factor is then computed with the gyrokinetic code GKW, using a quasi-linear approach, supported by a few non-linear simulations. The comparison of the quasi-linear predictions to the experimental values at mid-radius reveals two main regimes. At low normalised collisionality, ν * , and T e / T i < 1 , the gyrokinetic simulations quantitatively recover experimental carbon density profiles, provided that rotodiffusion is taken into account. In contrast, at higher ν * and T e / T i > 1 , the very hollow experimental carbon density profiles are never predicted by the simulations and the carbon density peaking is systematically over estimated. This points to a possible missing ingredient in this regime.
Effect of food and various antacids on the absorption of tenoxicam.
Day, R O; Lam, S; Paull, P; Wade, D
1987-01-01
1 Twelve healthy volunteers received a single oral dose of tenoxicam 20 mg on six occasions separated by 3 weeks. 2 The six occasions were: fasted overnight; postprandial; fasting and 15 ml aluminium hydroxide gel; postprandial and 15 ml aluminium hydroxide gel; fasting and 15 ml aluminium and magnesium hydroxide gel; postprandial and 15 ml aluminium and magnesium hydroxide gel. 3 Twenty plasma samples were collected over 15 days following dosing with tenoxicam. 4 The following kinetic parameters for plasma tenoxicam were compared: peak concentrations, time taken to reach peak concentrations, area under the plasma concentration-time curve (AUC) and half-life of elimination. 5 Food lengthened the time taken to reach peak tenoxicam concentrations (5.82 +/- 4.6 vs 1.84 +/- 1.0 h in the fasting state; P less than 0.02) and marginally reduced the peak concentrations achieved. AUC was not affected by any of the different regimens. 6 These effects of food on tenoxicam bioavailability are unlikely to be of clinical significance during chronic dosing with the drug. PMID:3499163
Wang, Qiong; Hong, Wanshu; Chen, Shixi; Zhang, Qiyong
2008-02-01
Variation in the production of the plasma steroid hormones E(2), 17alpha-OHP and T in females and T and 11-KT in males, was investigated in the mudskipper Boleophthalmus pectinirostris during the spawning season. Females with oocytes at the vitellogenic stage (GSI 5.97-6.86%) and mature males with GSI of 0.255-0.288% were collected at intervals of 3-4 days within the two complete semilunar cycles from May 31 to June 30, 2006. The results showed that variations in the levels of plasma steroid hormones were synchronized obviously with semilunar periodicity in both females and males. Each steroid hormone level exhibited two cycles, each cycle with a peak. In females, the first peaks in plasma E(2), 17alpha-OHP and T levels were observed 3 days after the first lunar quarter, and the second ones, 4 days after the last lunar quarter. In males, the first peaks of plasma T and 11-KT levels occurred 3 days after the first lunar quarter, and the second ones, at the last lunar quarter. The fact that, in the present study, changes in the levels of plasma steroid hormones were synchronized with semilunar periodicity, although the fish were at the same stages of gonadal development, suggests that variation of plasma steroid hormones is basically regulated by biological rhythms (Zeitgebers), and that tidal movement (with its semilunar periodicity) is the major environmental factor stimulating steroid hormone production in B. pectinirostris.
NASA Astrophysics Data System (ADS)
Cetiner, S. O.; Stoltz, P.; Messmer, P.; Cambier, J.-L.
2008-01-01
The prebreakdown and breakdown phases of a pseudospark discharge are investigated using the two-dimensional kinetic plasma simulation code OOPIC™ PRO. Trends in the peak electron current at the anode are presented as function of the hollow cathode dimensions and mean seed injection velocities at the cavity back wall. The plasma generation process by ionizing collisions is examined, showing the effect on supplying the electrons that determine the density of the beam. The mean seed velocities used here are varied between the velocity corresponding to the energy of peak ionization cross section, 15 times this value and no mean velocity (i.e., electrons injected with a temperature of 2.5eV). The reliance of the discharge characteristics on the penetrating electric field is shown to decrease as the mean seed injection velocity increases because of its ability to generate a surplus plasma independent of the virtual anode. As a result, the peak current increases with the hollow cathode dimensions for the largest average injection velocity, while for the smallest value it increases with the area of penetration of the electric field in the hollow cathode interior. Additionally, for a given geometry an increase in the peak current with the surplus plasma generated is observed. For the largest seed injection velocity used a dependence of the magnitude of the peak current on the ratio of the hole thickness and hollow cathode depth to the hole height is demonstrated. This means similar trends of the peak current are generated when the geometry is resized. Although the present study uses argon only, the variation in the discharge dependencies with the seed injection energy relative to the ionization threshold is expected to apply independently of the gas type. Secondary electrons due to electron and ion impact are shown to be important only for the largest impact areas and discharge development times of the study.
Coiro, Vittorio; Volpi, Riccardo; Casti, Amos; Maffei, Maria Ludovica; Stella, Adriano; Volta, Elio; Chiodera, Paolo
2011-06-01
• Alprazolam (ALP), a benzodiazepine activating GABAergic receptors, is involved in ACTH secretion. • This study demonstrates a partial opioid influence in the inhibitory effect of ALP on the release of ACTH/cortisol during physical exercise. To establish the possible involvement of alprazolam (ALP) and/or opiates in the mechanism underlying the ACTH/cortisol response to physical exercise. Tests were carried out under basal conditions (exercise control test), exercise plus ALP (50 µg at time -90 min), naloxone (10 mg at time 0) or ALP plus naloxone. Plasma ACTH and serum cortisol concentrations were evaluated in blood samples taken before, during and after the bicycle ergometer tests. ACTH and cortisol concentrations rose significantly after physical exercise. Maximum peak at time 15 min (P ≤ 0.01 vs. baseline) for ACTH and at time 30 min (P ≤ 0.01 vs. baseline) for cortisol. In the presence of naloxone, the ACTH and cortisol responses were significantly increased (maximum peak at time 20 min, P ≤ 0.02 vs. control test for ACTH, and at time 30 min (P ≤ 0.01 vs. baseline) for cortisol) whereas they were abolished by ALP. When ALP and naloxone were given together, the inhibitory effect of ALP was partial. These data demonstrate an inhibitory effect of ALP in the regulation of the ACTH/cortisol response to physical exercise in man and suggest that GABAergic receptor activating benzodiazepines and opioids interact in the neuroendocrine secretion of ACTH/cortisol. © 2011 The Authors. British Journal of Clinical Pharmacology © 2011 The British Pharmacological Society.
Samuelsen, O B
2010-02-01
The pharmacokinetic profile of the antiparasitic agent emamectin benzoate was studied in plasma after intravenous (i.v.) injection and in plasma, muscle and skin following oral (p.o.) administration to cod, Gadus morhua, held in sea water at 9 degrees C and weighing 100-200 g. Following i.v. injection, the plasma drug concentration-time profile showed two distinct phases. The plasma distribution half-life (t(1/2)alpha) was estimated as 2.5 h, the elimination half-life (t(1/2)beta) as 216 h, the total body clearance (Cl(T)) as 0.0059 L kg(-1) h(-1) and mean residence time (MRT) as 385 h. The volume of distribution at steady state, V(d(ss)), was calculated to be 1.839 L kg(-1). Following p.o. administration the peak plasma concentration (C(max)) was 15 ng mL(-1), the time to peak plasma concentration (T(max)) was 89 h and t(1/2)beta was 180 h. The highest concentration in muscle (21 ng g(-1)) was measured after 7 days and t(1/2)beta was calculated to be 247 h. For skin, a peak concentration of 28 ng g(-1) at 3 days was observed and a t(1/2)beta of 235 h was determined. The bioavailability following p.o. administration was calculated to be 38%.
Liao, Tzu-Chieh; Keyak, Joyce H; Powers, Christopher M
2018-02-27
The purpose of this study is to determine whether recreational runners with patellofemoral pain (PFP) exhibit greater peak patella cartilage stress compared to pain-free runners. A secondary purpose was to determine the kinematic and/or kinetic predictors of peak patella cartilage stress during running. Twenty-two female recreational runners participated (12 with PFP and 10 pain-free controls). Patella cartilage stress profiles were quantified using subject-specific finite element models simulating the maximum knee flexion angle during stance phase of running. Input parameters to the finite element model included subject-specific patellofemoral joint geometry, quadriceps muscle forces, and lower extremity kinematics in the frontal and transverse planes. Tibiofemoral joint kinematics and kinetics were quantified to determine the best predictor of stress using stepwise regression analysis. Compared to the pain-free runners, those with PFP exhibited greater peak hydrostatic pressure (PFP vs. control, 21.2 ± 5.6 MPa vs. 16.5 ± 4.6 MPa) and maximum shear stress (11.3 ± 4.6 MPa vs. 8.7 ± 2.3 MPa). Knee external rotation was the best predictor of peak hydrostatic pressure and peak maximum shear stress (38% and 25% of variances, respectively) followed by the knee extensor moment (21% and 25% of variances, respectively). Runners with PFP exhibit greater peak patella cartilage stress during running compared to pain-free individuals. The combination of knee external rotation and a high knee extensor moment best predicted elevated peak stress during running.
Characterizing ISS Charging Environments with On-Board Ionospheric Plasma Measurements
NASA Technical Reports Server (NTRS)
Minow, Jospeh I.; Craven, Paul D.; Coffey, Victoria N.; Schneider, Todd A.; Vaughn, Jason A.; Wright Jr, Kenneth; Parker, Paul D.; Mikatarian, Ronald R.; Kramer, Leonard; Hartman, William A.;
2008-01-01
Charging of the International Space Station (ISS) is dominated by interactions of the biased United States (US) 160 volt solar arrays with the relatively high density, low temperature plasma environment in low Earth orbit. Conducting surfaces on the vehicle structure charge negative relative to the ambient plasma environment because ISS structure is grounded to the negative end of the US solar arrays. Transient charging peaks reaching potentials of some tens of volts negative controlled by photovoltaic array current collection typically occur at orbital sunrise and sunset as well as near orbital noon. In addition, surface potentials across the vehicle structure vary due to an induced v x B (dot) L voltage generated by the high speed motion of the conducting structure across the Earth's magnetic field. Induced voltages in low Earth orbit are typically only approx.0.4 volts/meter but the approx.100 meter scale dimensions of the ISS yield maximum induced potential variations ofapprox.40 volts across the vehicle. Induced voltages are variable due to the orientation of the vehicle structure and orbital velocity vector with respect to the orientation of the Earth's magnetic field along the ISS orbit. In order to address the need to better understand the ISS spacecraft potential and plasma environments, NASA funded development and construction of the Floating Potential Measurement Unit (FPMU) which was deployed on an ISS starboard truss arm in August 2006. The suite of FPMU instruments includes two Langmuir probes, a plasma impedance probe, and a potential probe for use in in-situ monitoring of electron temperatures and densities and the vehicle potential relative to the plasma environment. This presentation will describe the use of the FPMU to better characterize interactions of the ISS with the space environment, changes in ISS charging as the vehicle configuration is modified during ISS construction, and contributions of FPMU vehicle potential and plasma environment measurements to investigations of on-orbit anomalies in ISS systems.
Simulation Study on Neoclassical Poloidal Viscosity in Helical Plasmas
NASA Astrophysics Data System (ADS)
Satake, Shinsuke
2012-10-01
In helical plasma confinement devices such as LHD, CHS and TU-Heliac, biasing experiments have been carried out to study the relationships among the ExB rotation, neoclassical poloidal viscosity (NPV), JxB torque of biasing current, and plasma confinement properties. In earlier studies using simple analytic formulae, it has been suggested that the transition phenomena of plasma transport found in the biasing experiments is attributed to nonlinear dependence of NPV on poloidal Mach number of the ExB rotation speed, or Mp. To study the NPV dependence on Mp in LHD biasing plasmas more in detail, we have applied FORTEC-3D drift-kinetic Monte-Carlo simulation code which can evaluate NPV precisely in realistic 3-D magnetic configurations. This is the first application of the massive neoclassical transport simulation to study the dependence of NPV on the magnetic configuration and rotation speed. In LHD plasmas, neoclassical transport properties such as radial particle transport and viscosity can be controlled by shifting the magnetic axis position. Our simulation study revealed that the NPV is drastically reduced if magnetic axis moves from 3.75m to 3.53m. As the biasing voltage, or Mp increases, it is found that the local maximum of NPV appears when |Mp|˜1, at which the transition of plasma transport properties is expected to happen. The transition Mp value is much smaller than that is predicted from simple analytic estimations. Comparing with the data from LHD biasing experiments, we confirmed that Mp near the electrode is about unity when a transition occurs, and also found that the peak NPV value at |Mp|˜1 agrees with the magnitude of JxB torque at the transition point. This suggests that our simulation successfully explains the nonlinear dependence of NPV and can give a quantitative evaluation of NPV in realistic LHD biasing experiment.
Königsbrügge, Oliver; Weigel, Günter; Quehenberger, Peter; Pabinger, Ingrid; Ay, Cihan
2018-02-07
The effect of direct oral anticoagulants (DOACs) on turbidimetric measurements of plasma clot formation and susceptibility to fibrinolysis may facilitate a comparison between different classes of anticoagulants in plasma samples. We obtained 424 citrate plasma samples from 226 atrial fibrillation patients on anticoagulation and 24 samples without anticoagulation serving as controls. As comparators, we measured the international normalized ratio (INR) for phenprocoumon samples (N = 166), anti-Xa for low molecular weight heparin (LMWH) samples (N = 42), and DOAC levels with mass spectrometry (dabigatran N = 40, rivaroxaban N = 110, apixaban N = 42). Plasma clot formation and lysis were recorded continuously on a photometer after addition of an activation mix (tissue factor 2 pmol/l and tissue plasminogen activator 333 ng/ml). We used linear regression and ANCOVA for correlation analysis. Clot formation lag phase was prolonged in the presence of anticoagulants in a concentration-dependent manner for DOACs (dabigatran Spearman r = 0.74; rivaroxaban r = 0.78; apixaban r = 0.72, all p < 0.0001), INR dependent for phenprocoumon (r = 0.59, p < 0.0001), anti-Xa level dependent in LMWH samples (r = 0.90, p < 0.0001). Maximum rate of clot formation and peak clot turbidity were reduced in the presence of anticoagulants, but correlated only moderately with the comparator measures of anticoagulation. The clot lysis time was inversely correlated with DOAC concentrations in the presence of recombinant thrombomodulin. A direct ex vivo comparison between the effects of different classes of anticoagulants is possible with turbidimetric measurement of plasma clot formation and lysis. Anticoagulation inhibited clot formation in a plasma concentration manner for DOACs, INR dependent for phenprocoumon, and anti-Xa dependent for LMWH. Susceptibility to fibrinolysis increased with increasing DOAC concentrations.
Laser beam-plasma plume interaction during laser welding
NASA Astrophysics Data System (ADS)
Hoffman, Jacek; Moscicki, Tomasz; Szymanski, Zygmunt
2003-10-01
Laser welding process is unstable because the keyhole wall performs oscillations which results in the oscillations of plasma plume over the keyhole mouth. The characteristic frequencies are equal to 0.5-4 kHz. Since plasma plume absorbs and refracts laser radiation, plasma oscillations modulate the laser beam before it reaches the workpiece. In this work temporary electron densities and temperatures are determined in the peaks of plasma bursts during welding with a continuous wave CO2 laser. It has been found that during strong bursts the plasma plume over the keyhole consists of metal vapour only, being not diluted by the shielding gas. As expected the values of electron density are about two times higher in peaks than their time-averaged values. Since the plasma absorption coefficient scales as ~N2e/T3/2 (for CO2 laser radiation) the results show that the power of the laser beam reaching the metal surface is modulated by the plasma plume oscillations. The attenuation factor equals 4-6% of the laser power but it is expected that it is doubled by the refraction effect. The results, together with the analysis of the colour pictures from streak camera, allow also interpretation of the dynamics of the plasma plume.
Teuscher, Nathan S.; Kupper, Robert J.; Chang, Wei-Wei; Greenhill, Laurence; Newcorn, Jeffrey H.; Connor, Daniel F.; Wigal, Sharon
2014-01-01
Abstract Objectives: The purpose of this study was to evaluate the relative bioavailability and safety of a multilayer extended-release bead methylphenidate (MPH) hydrochloride 80 mg (MPH-MLR) capsule or sprinkles (37% immediate-release [IR]) versus MPH hydrochloride IR(Ritalin®) tablets, and to develop a pharmacokinetic (PK) model simulating MPH concentration-time data for different MPH-MLR dosage strengths. Methods: This was a single-center, randomized, open-label, three-period crossover study conducted in 26 fasted healthy adults (mean weight±standard deviation, 70.4±11.7 kg) assigned to single-dose oral MPH-MLR 80 mg capsule or sprinkles with applesauce, or Ritalin IR 25 mg (1×5 mg and 1×20 mg tablet) administered at 0, 4, and 8 hours. Results: MPH-MLR 80 mg capsule and sprinkles were bioequivalent; ratios for maximum concentration (Cmax), area under plasma drug concentration versus time curve (AUC)0-t, and AUC0-inf were 1.04 (95% confidence interval [CI], 96.3–112.4), 0.99 (95% CI, 95.3–102.8), and 0.99 (95% CI, 95.4–103.0), respectively. MPH-MLR capsule/sprinkles produced highly comparable, biphasic profiles of plasma MPH concentrations characterized by rapid initial peak, followed by moderate decline until 5 hours postdose, and gradual increase until 7 hours postdose, culminating in an attenuated second peak. Based on 90% CIs, total systemic exposure to MPH-MLR 80 mg capsule/sprinkles was similar to that for Ritalin IR 25 mg three times daily, but marked differences in Cmax values indicated that MPH-MLR regimens were not bioequivalent to Ritalin. MPH Cmax and total systemic exposure over the first 4 hours postdose with MPH-MLR capsule/sprinkles was markedly higher than that associated with the first dose of Ritalin. All study drugs were safe and well tolerated. The PK modeling in adults suggested that differences in MPH pharmacokinetics between MPH-MLR and Ritalin are the result of dosage form design attributes and the associated absorption profiles of MPH. Conclusions: MPH-MLR 80 mg provides a long-acting biphasic pattern of plasma MPH concentrations with one less peak and trough than Ritalin IR. PMID:25514542
Adjei, Akwete; Teuscher, Nathan S; Kupper, Robert J; Chang, Wei-Wei; Greenhill, Laurence; Newcorn, Jeffrey H; Connor, Daniel F; Wigal, Sharon
2014-12-01
The purpose of this study was to evaluate the relative bioavailability and safety of a multilayer extended-release bead methylphenidate (MPH) hydrochloride 80 mg (MPH-MLR) capsule or sprinkles (37% immediate-release [IR]) versus MPH hydrochloride IR(Ritalin(®)) tablets, and to develop a pharmacokinetic (PK) model simulating MPH concentration-time data for different MPH-MLR dosage strengths. This was a single-center, randomized, open-label, three-period crossover study conducted in 26 fasted healthy adults (mean weight±standard deviation, 70.4±11.7 kg) assigned to single-dose oral MPH-MLR 80 mg capsule or sprinkles with applesauce, or Ritalin IR 25 mg (1×5 mg and 1×20 mg tablet) administered at 0, 4, and 8 hours. MPH-MLR 80 mg capsule and sprinkles were bioequivalent; ratios for maximum concentration (Cmax), area under plasma drug concentration versus time curve (AUC)0-t, and AUC0-inf were 1.04 (95% confidence interval [CI], 96.3-112.4), 0.99 (95% CI, 95.3-102.8), and 0.99 (95% CI, 95.4-103.0), respectively. MPH-MLR capsule/sprinkles produced highly comparable, biphasic profiles of plasma MPH concentrations characterized by rapid initial peak, followed by moderate decline until 5 hours postdose, and gradual increase until 7 hours postdose, culminating in an attenuated second peak. Based on 90% CIs, total systemic exposure to MPH-MLR 80 mg capsule/sprinkles was similar to that for Ritalin IR 25 mg three times daily, but marked differences in Cmax values indicated that MPH-MLR regimens were not bioequivalent to Ritalin. MPH Cmax and total systemic exposure over the first 4 hours postdose with MPH-MLR capsule/sprinkles was markedly higher than that associated with the first dose of Ritalin. All study drugs were safe and well tolerated. The PK modeling in adults suggested that differences in MPH pharmacokinetics between MPH-MLR and Ritalin are the result of dosage form design attributes and the associated absorption profiles of MPH. MPH-MLR 80 mg provides a long-acting biphasic pattern of plasma MPH concentrations with one less peak and trough than Ritalin IR.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swahn, M.L.; Wang, G.; Aedo, A.R.
RU 486 is a synthetic steroid which acts as an antiprogestin at the receptor level. The clinical usefulness of the compound for menstrual regulation and termination of early pregnancy is currently being evaluated. The aim of the present study was to determine the plasma levels of RU 486 following the oral administration of the compound to 42 pregnant and 10 non-pregnant women. The levels of RU 486 were measured by a radioimmunoassay method which uses chromatography on Sephadex LH 20 columns. The identity of the compound assayed as RU 486 was confirmed, but the presence of small amounts of twomore » highly cross-reacting metabolites (monodemethyl and didemethyl RU 486) in the analyzed fractions could not be excluded. Following the ingestion of a single tablet containing 25 and 50 mg of the compound, a peak plasma value of approximately 3.5 to 4.0 mumol/l in both the pregnant and non-pregnant subjects was reached one to two hours later. The half-lives of elimination were about 20 hours in both the pregnant and the non-pregnant women. Following the repeated oral administration of 50, 100 or 200 mg of RU 486 daily for four days, maximum plasma levels of 2.9, 4.5 and 5.4 mumol/l, respectively, were found. Thus, the increase in plasma levels was not directly proportional to the increase in the dose. No accumulation of RU 486 in the plasma was found, even when the duration of treatment was prolonged to six days. The data partly explain the reported lack of relation between ingested dose and frequency of induced abortion and they may be useful for designing future studies on the use of compound to prevent implantation, induce menstruation or terminate an early pregnancy.« less
Streaked Thomson Scattering on Laboratory Plasma Jets
NASA Astrophysics Data System (ADS)
Banasek, Jacob; Byvank, Tom; Rocco, Sophia; Kusse, Bruce; Hammer, David
2017-10-01
Streaked Thomson scattering measurements have been performed on plasma jets created from a 15 μm thick radial Al or Ti foil load on COBRA, a 1 MA pulsed power machine. The goal was to measure the electron temperatures inside the center of the plasma jet created by the radial foil. The laser used for these measurements had a maximum energy of 10 J at 526.5 nm in a 3 ns duration pulse. Early experiments showed using the full energy significantly heats the 5 ×1018 cm-3 jet by inverse bremsstrahlung radiation. Here we used a streak camera to record the scattered spectrum and measure the evolving electron temperature of this laser heated jet. Analysis of the streak camera image showed that the electron temperature of the Al jet was increased from about 25 eV to 80-100 eV within about 2 ns. The Ti jets showed even stronger interaction with the laser, being heated to over 150 eV, and showed some heating even when only 1 J of laser energy was used. Also, the ion-acoustic peaks in the scattered spectrum from the Ti jets were significantly narrower than those from Al jets. Initial results will also be presented with scattered spectra taken at two different times within a single experiment by splitting the probe beam. This research is supported by the NNSA Stewardship Sciences Academic Programs under DOE Cooperative Agreement DE-NA0001836.
Pulsed plasma chemical synthesis of carbon-containing titanium and silicon oxide based nanocomposite
NASA Astrophysics Data System (ADS)
Kholodnaya, Galina; Sazonov, Roman; Ponomarev, Denis; Zhirkov, Igor
2018-03-01
The paper presents the results of the experimental investigation of the physical and chemical properties of the TixSiyCzOw composite nanopowders, which were first obtained using a pulsed plasma chemical method. The pulsed plasma chemical synthesis was achieved using a technological electron accelerator (TEA-500). The parameters of the electron beam are as follows: 400-450 keV electron energy, 60 ns half-amplitude pulse duration, up to 200 J pulse energy, and 5 cm beam diameter. The main physical and chemical properties of the obtained composites were studied (morphology, chemical, elemental and phase composition). The morphology of the TixSiyCzOw composites is multiform. There are large round particles, with an average size of above 150 nm. Besides, there are small particles (an average size is in the range of 15-40 nm). The morphology of small particles is in the form of crystallites. In the TixSiyCzOw synthesised composite, the peak with a maximum of 946 cm-1 was registered. The presence of IR radiation in this region of the spectrum is typical for the deformation of atomic oscillations in the Si‒О‒Ti bond, which indicates the formation of the solid solution. The composites consist of two crystal phases - anatase and rutile. The prevailing phase of the crystal structure is rutile.
NASA Astrophysics Data System (ADS)
Klir, D.; Cikhardt, J.; Kravarik, J.; Kubes, P.; Rezac, K.; Sila, O.; Shishlov, A.; Cherdizov, R.; Fursov, F.; Kokshenev, V.; Kovalchuk, B.; Kurmaev, N.; Labetsky, A.; Ratakhin, N.; Orcikova, H.; Turek, K.
2013-10-01
Fusion neutrons were produced with a deuterium gas-puff z-pinch on the GIT-12 generator at the Institute of High Current Electronics in Tomsk. The peak neutron yield from DD reactions reached Yn = (2 . 9 +/- 0 . 3) ×1012 at 100 μg/cm linear mass density of deuterium, 700 ns implosion time and 2.7 MA current. Such a neutron yield means that the scaling law of deuterium z-pinches Yn ~I4 was extended to 3 MA currents. The further increase of neutron yields up to (3 . 7 +/- 0 . 4) ×1012 was achieved by placing a deuterated polyethylene catcher onto the axis. Maximum neutron energies of 15 and 22 MeV were observed by radial and axial nToF detectors, respectively. A stack of CR-39 track detectors showed up to 40 MeV deuterons (or 30 MeV protons) on the z-pinch axis. Since the energy input into plasmas was 70 kJ, the number of DD neutrons per one joule of stored plasma energy exceeded the value of 5 ×107 . This value implies that deuterium gas-puff z-pinches belong to the most efficient plasma-based sources of DD neutrons. This work was partially supported by the GACR grant No. P205/12/0454 and by the RFBR research project No. 13-08-00479-a.
Tůma, Petr; Gojda, Jan
2015-08-01
A CE method with contactless conductivity detection has been developed for the clinical determination of the branched chain amino acids (BCAAs) valine, isoleucine and leucine in human blood plasma. The CE separation was performed in an optimised BGE with composition of 3.2 M acetic acid in 20% v/v methanol, pH 2.0. The achieved separation time was 125 s when using a capillary with an effective length of 14.7 cm, electric field intensity of 0.96 kV/cm and simultaneous application of a hydrodynamic pressure of 50 mbar. The separation efficiency in blood plasma equalled 461 000 theoretical plates/m for valine and isoleucine, and 455 000 theoretical plates/m for leucine; the detection limits are equal to 0.4 μM for all three amino acids. The RSD values for repeatability of the migration time equalled 0.1% for measurements during a single day and 0.3% for measurements on different days; the RSD values for repeatability of the peak areas equalled 2.3-2.6% for measurements during a single day and 2.7-4.6% for measurements on different days. It followed from the performed tests that the plasmatic levels of BCAAs attain a maximum 60 min after intravenous application of an infusion of BCAAs. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sohbatzadeh, Farshad, E-mail: f.sohbat@umz.ac.ir; Nano and Biotechnology Research Group, Faculty of Basic Sciences, University of Mazandaran, Babolsar 47416-95447, Mazandaran; Omran, Azadeh Valinataj
2014-11-15
In this work, we developed transporting atmospheric pressure cold plasma using single electrode configuration through a sub-millimetre flexible dielectric tube beyond 100 cm. It was shown that the waveform of the applied high voltage is essential for controlling upstream and downstream plasma inside the tube. In this regard, sawtooth waveform enabled the transport of plasma with less applied high voltage compared to sinusoidal and pulsed form voltages. A cold plasma string as long as 130 cm was obtained by only 4 kV peak-to-peak sawtooth high voltage waveform. Optical emission spectroscopy revealed that reactive chemical species, such as atomic oxygen and hydroxyl, are generatedmore » at the tube exit. The effect of tube diameter on the transported plasma was also examined: the smaller the diameter, the higher the applied voltage. The device is likely to be used for sterilization, decontamination, and therapeutic endoscopy as already suggested by other groups in recent past years.« less
NASA Astrophysics Data System (ADS)
Kim, Duk Jae; Park, Jeongwon; Geon Han, Jeon
2016-08-01
We show results of the patterning of graphene layers on poly(ethylene terephthalate) (PET) films through remote atmospheric-pressure dielectric barrier discharge plasma. The size of plasma discharge electrodes was adjusted for large-area and role-to-role-type substrates. Optical emission spectroscopy (OES) was used to analyze the characteristics of charge species in atmospheric-pressure plasma. The OES emission intensity of the O2* peaks (248.8 and 259.3 nm) shows the highest value at the ratio of \\text{N}2:\\text{clean dry air (CDA)} = 100:1 due to the highest plasma discharge. The PET surface roughness and hydrophilic behavior were controlled with CDA flow rate during the process. Although the atmospheric-pressure plasma treatment of the PET film led to an increase in the FT-IR intensity of C-O bonding at 1240 cm-1, the peak intensity at 1710 cm-1 (C=O bonding) decreased. The patterning of graphene layers was confirmed by scanning electron microscopy and Raman spectroscopy.
Turbulent inward pinch of plasma confined by a levitated dipole magnet
NASA Astrophysics Data System (ADS)
Boxer, A. C.; Bergmann, R.; Ellsworth, J. L.; Garnier, D. T.; Kesner, J.; Mauel, M. E.; Woskov, P.
2010-03-01
The rearrangement of plasma as a result of turbulence is among the most important processes that occur in planetary magnetospheres and in experiments used for fusion energy research. Remarkably, fluctuations that occur in active magnetospheres drive particles inward and create centrally peaked profiles. Until now, the strong peaking seen in space has been undetectable in the laboratory because the loss of particles along the magnetic field is faster than the net driven flow across the magnetic field. Here, we report the first laboratory measurements in which a strong superconducting magnet is levitated and used to confine high-temperature plasma in a configuration that resembles planetary magnetospheres. Levitation eliminates field-aligned particle loss, and the central plasma density increases markedly. The build-up of density characterizes a sustained turbulent pinch and is equal to the rate predicted from measured electric-field fluctuations. Our observations show that dynamic principles describing magnetospheric plasma are relevant to plasma confined by a levitated dipole.
Pharmacokinetics of EMLA cream 5% application to oral mucosa.
Vickers, E. R.; Marzbani, N.; Gerzina, T. M.; McLean, C.; Punnia-Moorthy, A.; Mather, L.
1997-01-01
Plasma concentrations of lidocaine and prilocaine were measured following the application of a 5% eutectic mixture of local anesthetics (EMLA) topical anesthetic cream to the oral mucosa of twelve subjects. For each subject, a total of 8 g of EMLA was occluded to 18 cm2 of buccal mucosa for 30 min. Analysis was carried out by high-pressure liquid chromatography, and results showed peak concentrations at 40 min for lidocaine and prilocaine. The maximum concentration measured in any subject was 418 ng/ml for lidocaine and 223 ng/ml for prilocaine, well below known toxic levels. No adverse local effects were observed from a 30-min application of EMLA. A follow-up pilot study assessing the clinical efficacy of EMLA for achieving sufficient analgesia for restorative procedures showed that the cream was successful in 75% of subjects tested. PMID:9481979
Pharmacokinetics of penciclovir after oral administration of its prodrug famciclovir to horses.
Tsujimura, Koji; Yamada, Masayuki; Nagata, Shun-ichi; Yamanaka, Takashi; Nemoto, Manabu; Kondo, Takashi; Kurosawa, Masahiko; Matsumura, Tomio
2010-03-01
We investigated the pharmacokinetics of penciclovir after oral administration of its prodrug famciclovir to horses. Following an oral dose of famciclovir at 20 mg/kg, maximum plasma concentrations of penciclovir occurred between 0.75 and 1.5 hr (mean 0.94 + or - 0.38 hr) after dosing and were in the range 2.22 to 3.56 microg/ml (mean 2.87 + or - 0.61 microg/ml). The concentrations of penciclovir declined in a biphasic manner after the peak concentration was attained. The mean half-life of the rapid elimination phase was 1.73 + or - 0.34 hr whereas that of the slow elimination phase was 34.34 + or - 13.93 hr. These pharmacokinetic profiles observed were similar to those of another antiherpesvirus drug, acyclovir, previously reported in horses following oral dosing of its prodrug valacyclovir.
Time-dependent Tonks-Langmuir model is unstable
NASA Astrophysics Data System (ADS)
Sheridan, T. E.; Baalrud, S. D.
2017-11-01
We investigate a time-dependent extension of the Tonks-Langmuir model for a one-dimensional plasma discharge with collisionless kinetic ions and Boltzmann electrons. Ions are created uniformly throughout the volume and flow from the center of the discharge to the boundary wall due to a self-consistent, zero-order electric field. Solving this model using a particle-in-cell simulation, we observe coherent low-frequency, long-wavelength unstable ion waves which move toward the boundary with a speed below both the ion acoustic speed and the average ion velocity. The maximum amplitude of the wave potential fluctuations peaks at ≈0.09 Te near the wall, where Te is the electron temperature in electron volts. Using linear kinetic theory, we identify this instability as slow ion-acoustic wave modes which are destabilized by the zero-order electric field.
Brazed graphite/refractory metal composites for first-wall protection elements
NASA Astrophysics Data System (ADS)
Šmid, I.; Croessmann, C. D.; Salmonson, J. C.; Whitley, J. B.; Kny, E.; Reheis, N.; Kneringer, G.; Nickel, H.
1991-03-01
The peak surface heat flux deposition on divertor elements of near term fusion devices is expected to exceed 10 MW/m 2. The needed reliability of brazed plasma interactive components, particularly under abnormal operating conditions with peak surface temperatures well beyond 1000°C, makes refractory metallic substrates and brazes with a high melting point very attractive. TZM, a high temperature alloy of molybdenum, and isotropic graphite, materials very closely matched in their thermal expansion, were brazed with four high-temperature brazes. The brazes used were Zr, 90Ni/10Ti, 90Cu/10Ti and 70Ag/27Cu/3Ti (nominal composition prior to brazing, wt%). The resulting composite tiles of 50 × 50 mm2 with a TZM thickness of 5 mm and a graphite thickness of 10 mm have been tested in high heat flux simulation for their thermal fatigue properties. Up to 600 loading cycles were carried out with an average heat flux of 10 MW/m 2 for 0.5 s pulses. The maximum surface temperature was 1100°C. In support of the experiment, the thermal response and temperature gradients of the samples were investigated using a finite element model.
McCormick, S.D.; Shrimpton, J.M.; Moriyama, S.; Bjornsson, Bjorn Thrandur
2007-01-01
In order to elucidate the developmental basis for smolting, Atlantic salmon, Salmo salar, parr ( 12.5??cm) were exposed to natural daylength (LDN) and increased daylength (LD16:8) starting in late February and gill Na+,K+-ATPase activity and circulating hormone levels monitored from January to May. Gill Na+,K+-ATPase activity remained low and constant in both groups of parr. In smolts, gill Na+,K+-ATPase began increasing in late February in both photoperiods, but was significantly higher in the LD16:8 group from March through April. Smolts exposed to LD16:8 had dramatically elevated plasma GH within one week of increased daylength that remained high through April, whereas plasma GH of LDN smolts increased steadily beginning in late February and peaking in late April. Plasma GH levels of parr remained low in spring and did not respond to increased daylength. Plasma insulin-like growth factor I (IGF-I) levels were substantially higher in smolts than parr in January. Plasma IGF-I levels of parr increased steadily from January to May, but there was no influence of increased daylength. In smolts, plasma IGF-I of LD16:8 fish initially decreased in early March then increased in late March and April, whereas plasma IGF-I of LDN smolts increased steadily to peak levels in early April. Plasma cortisol was low in parr throughout spring and did not differ between photoperiod treatments. Plasma cortisol of LD16:8 smolts increased in early March and remained elevated through April, whereas in LDN smolts plasma cortisol did not increase until early April and peaked in late April. Plasma thyroid hormones were generally higher in smolts than in parr, but there was no clear effect of increased daylength in parr or smolts. The greater capacity of the GH/IGF-I and cortisol axes to respond to increased daylength may be a critical factor underlying smolt development. ?? 2007 Elsevier B.V. All rights reserved.
Clinical Pharmacokinetics and Pharmacodynamics of Febuxostat.
Kamel, Bishoy; Graham, Garry G; Williams, Kenneth M; Pile, Kevin D; Day, Richard O
2017-05-01
Febuxostat is a xanthine oxidoreductase inhibitor that has been developed to treat chronic gout. In healthy subjects, the pharmacokinetic parameters of febuxostat after multiple oral dose administration include an oral availability of about 85 %, an apparent oral clearance (CL/F) of 10.5 ± 3.4 L/h and an apparent volume of distribution at steady state (V ss /F) of 48 ± 23 L. The time course of plasma concentrations follows a two-compartment model. The initial half-life (t ½ ) is approximately 2 h and the terminal t ½ determined at daily doses of 40 mg or more is 9.4 ± 4.9 h. Febuxostat is administered once daily. The maximum (peak) plasma concentrations are approximately 100-fold greater than the trough concentrations. Consequently, there is no significant accumulation of the drug during multiple dose administration. There are few data on the pharmacokinetics of febuxostat in patients with gout. While the pharmacokinetic parameters are not affected by mild to moderate hepatic impairment, there is no consensus on whether renal impairment has any effect on the pharmacokinetics of febuxostat. Febuxostat is extensively metabolised by oxidation (approximately 35 %) and acyl glucuronidation (up to 40 %); febuxostat acyl glucuronides are cleared by the kidney. In healthy subjects treated with multiple doses of febuxostat 10-240 mg, the concentrations of serum urate are reduced by a maximum of about 80 %. The percentage reduction in the concentrations of serum urate is slightly less in gouty patients than in healthy subjects.
Karp, J E; Humphrey, R L; Burke, P J
1981-03-01
Malignant plasma cell proliferation and induced humoral stimulatory activity (HSA) occur in vivo at a predictable time following drug administration. Sequential sera from 11 patients with poor-risk multiple myeloma (MM) undergoing treatment with Cytoxan (CY) 2400 mq/sq m were assayed for their in vitro effects on malignant bone marrow plasma cell tritiated thymidine (3HTdR) incorporation. Peak HSA was detected day 9 following CY. Sequential changes in marrow malignant plasma cell 3HTdR-labeling indices (LI) paralleled changes in serum activity, with peak LI occurring at the time of peak HS. An in vitro model of chemotherapy demonstrated that malignant plasma cell proliferation was enhanced by HSA, as determined by 3HTdR incorporation assay, 3HTdR LI, and tumor cells counts, and that stimulated plasma cells were more sensitive to cytotoxic effects of adriamycin (ADR) than were cells cultured in autologous pretreatment serum. Based on these studies, we designed a clinical trial to treat 12 CY-refractory poor-risk patients with MM in which ADR (60 mg/sq m) was administered at the time of peak HSA and residual tumor cell LI (day 9) following initial CY, 2400 mg/m (CY1ADR9). Eight of 12 (67%) responded to timed sequential chemotherapy with a greater than 50% decrement in monoclonal protein marker and a median survival projected to be greater than 8 mo duration (range 4-21+ mo). These clinical results using timed sequential CY1ADR9 compare favorably with results obtained using ADR in nonsequential chemotherapeutic regimens.
Plasma waves associated with the first AMPTE magnetotail barium release
NASA Technical Reports Server (NTRS)
Gurnett, D. A.; Anderson, R. R.; Bernhardt, P. A.; Luehr, H.; Haerendel, G.
1986-01-01
Plasma waves observed during the March 21, 1985, AMPTE magnetotail barium release are described. Electron plasma oscillations provided local measurements of the plasma density during both the expansion and decay phases. Immediately after the explosion, the electron density reached a peak of about 400,000/cu cm, and then started decreasing approximately as t to the -2.4 as the cloud expanded. About 6 minutes after the explosion, the electron density suddenly began to increase, reached a secondary peak of about 240/cu cm, and then slowly decayed down to the preevent level over a period of about 15 minutes. The density increase is believed to be caused by the collapse of the ion cloud into the diamagnetic cavity created by the initial expansion. The plasma wave intensities observed during the entire event were quite low. In the diamagnetic cavity, electrostatic emissions were observed near the barium ion plasma frequency, and in another band at lower frequencies. A broadband burst of electrostatic noise was also observed at the boundary of the diamagnetic cavity. Except for electron plasma oscillations, no significant wave activity was observed outside of the diamagnetic cavity.
Direct thrust measurements and modelling of a radio-frequency expanding plasma thruster
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lafleur, T.; Charles, C.; Boswell, R. W.
2011-08-15
It is shown analytically that the thrust from a simple plasma thruster (in the absence of a magnetic field) is given by the maximum upstream electron pressure, even if the plasma diverges downstream. Direct thrust measurements of a thruster are then performed using a pendulum thrust balance and a laser displacement sensor. A maximum thrust of about 2 mN is obtained at 700 W for a thruster length of 17.5 cm and a flow rate of 0.9 mg s{sup -1}, while a larger thrust of 4 mN is obtained at a similar power for a length of 9.5 cm andmore » a flow rate of 1.65 mg s{sup -1}. The measured thrusts are in good agreement with the maximum upstream electron pressure found from measurements of the plasma parameters and in fair agreement with a simple global approach used to model the thruster.« less
Plasma Waves Near the Magnetopause.
1981-06-01
be fairly typical of the late morning sector. In these three time intervals, the sheath magnetic field was southward of the ecliptic plane by...to peak sharply when the antenna was at spin phase 1400 ± 5. During this period, the mean magnetic field ecliptic longitude was about 2600 ± 5...implying that the electric field peaks at ecliptic longitude 40 or 2200, which is close to the plasma flow direction of 208. When all signals above 4 x 10
Kuo, Chao-Yin; Lin, Yuan-Yung
2017-01-01
Objectives. The primary objective for this study is to evaluate the advantages, disadvantages, surgical applicability, and outcome of the pulsed electron avalanche knife (PEAK) PlasmaBlade in transoral adenoidectomy under direct visualization using video nasoendoscopy. Patients and Methods. In this series, six cases of adenoid hypertrophy showing varying clinical presentations in relation to its clinical course were surgically treated using a PEAK PlasmaBlade. Before and after surgery, all patients underwent nasal endoscopy to define the grading of hypertrophic adenoids and postoperative outcome. Pure tone audiometry and tympanometry tests were carried out to investigate the change in middle and inner ear functions. Results. The mean follow-up period was 23.8 months. Postoperatively, symptoms of otitis media with effusion were all relieved with closure of the air-bone gap (6/6). Other relevant ear complaints like tinnitus were resolved (1/1) and aural fullness disappeared in 87.5% of ears (7/8). Nasal obstruction (2/2) and postnasal drip (2/2) were improved after surgery. Conclusions. Based on this preliminary report of a case series in a limited sample size, we suggest that using the transoral PEAK PlasmaBlade for adenoidectomy guided by video nasoendoscopy is a safe and feasible surgical technique, allowing remarkable outcomes by providing precise tissue removal, effective hemostasis, and painless postoperative recovery. PMID:28459055
Collocated ionosonde and dense GPS/GLONASS network measurements of midlatitude MSTIDs
NASA Astrophysics Data System (ADS)
Sherstyukov, R. O.; Akchurin, A. D.; Sherstyukov, O. N.
2018-04-01
To analyze midlatitude medium-scale travelling ionospheric disturbances (MSTIDs) over Kazan (55.5°N, 49°E), Russia, the sufficiently dense network of GNSS receivers (more than 150 ground-based stations) were used. For the first time, daytime MSTIDs in the form of their main signature (band structure) on high-resolution two-dimensional maps of the total electron content perturbation (TEC maps) are compared with ionosonde data with a high temporal resolution. For a pair of events, a relationship between southwestward TEC perturbations and evolution of F2 layer traces was established. So F2 peak frequency varied in antiphase to TEC perturbations. The ionograms show that during the movement of plasma depletion band (overhead ionosonde) the F2 peak frequency is the highest, and vice versa, for the plasma enhancement band, the F2 peak frequency is the lowest. One possible explanation may be a greater inclination of the radio beam from the vertical during the placement of a plasma enhancement band above the ionosonde, as evidenced by the absence of multiple reflections and the increased occurrence rate of additional cusp trace. Another possible explanation may be the redistribution of the electron content in the topside ionosphere with a small decrease in the F peak concentration of the layer with a small increase in TEC along the line-of-sight. Analysis of F2 peak frequency variation shows that observed peak-to-peak values of TEC perturbation equal to 0.4 and 1 TECU correspond to the values of ΔN/N equal to 13% and 28%. The need for further research is evident.
Photoelectric return-stroke velocity and peak current estimates in natural and triggered lightning
NASA Technical Reports Server (NTRS)
Mach, Douglas M.; Rust, W. David
1989-01-01
Two-dimensional photoelectric return stroke velocities from 130 strokes are presented, including 86 negative natural, 41 negative triggered, one positive triggered, and two positive natural return strokes. For strokes starting near the ground and exceeding 500 m in length, the average velocity is 1.3 + or - 0.3 X 10 to the 8th m/s for natural return strokes and 1.2 + or - 0.3 X 10 to the 8th m/s for triggered return strokes. For strokes with lengths less than 500 m, the average velocities are slightly higher. Using the transmission line model (TLM), the shortest segment one-dimensional return stroke velocity, and either the maximum or plateau electric field, it is shown that natural strokes have a peak current distribution that is lognormal with a median value of 16 kA (maximum E) or 12 kA (plateau E). Triggered lightning has a medium peak current value of 21 kA (maximum E) or 15 kA (plateau E). Correlations are found between TLM peak currents and velocities for triggered and natural subsequent return strokes, but not between TLM peak currents and natural first return stroke velocities.
1990-05-03
winter and a minimum in summer ; in contrast, at sunspot maximum the seasonal peaks tend to occur around the equinoxes and the minima in summer . ’riis is...more clearly seen in Figures 4(b) ahnd 4(c). Note that around sunspot maximum the summer noon value may be less than the summer midnight value. (3) The...seasonal variation of the midnight values show summer peaks and winter minima with high values near the peaks of the sunspot cycles and low values
The electromagnetic properties of plasma produced by hypervelocity impact
NASA Astrophysics Data System (ADS)
Zhang, Qingming; Gong, Liangfei; Ma, Yuefen; Long, Renrong; Gong, Zizheng
2018-02-01
The change of electron density in moving plasma in this paper is empirically determined according to multiple ground-based experimental results and the assumption of the Maxwell distribution. Moreover, the equation of the magnetic field intensity, dominated by the current due to the collective electron movement during the expansion, is presented on the basis of the Biot-Savart law, and its relationship with time and space is subsequently depicted. In addition, hypervelocity impact experiments on a 2AL12 target have been carried out using a two-stage light gas gun to accelerate a 2AL12 projectile of 6.4 mm to 6.2 km/s. Spiral coils are designed to measure the intensity of the electromagnetic field induced by this impact. The experimental results show that the magnetic field strength is an alternate pulse maintaining nearly 1 ms and its maximum is close to 15 μT, which is strong enough to interfere with the communication circuit and chip in spacecrafts. Lastly, numerical simulation of the magnetic field intensity using this experimental parameter reveals that the intensity in our estimation from our theory tends to be well consistent with the experimental data in the first peak of the pulse signal.
Cholesterol Alters the Dynamics of Release in Protein Independent Cell Models for Exocytosis
NASA Astrophysics Data System (ADS)
Najafinobar, Neda; Mellander, Lisa J.; Kurczy, Michael E.; Dunevall, Johan; Angerer, Tina B.; Fletcher, John S.; Cans, Ann-Sofie
2016-09-01
Neurons communicate via an essential process called exocytosis. Cholesterol, an abundant lipid in both secretory vesicles and cell plasma membrane can affect this process. In this study, amperometric recordings of vesicular dopamine release from two different artificial cell models created from a giant unilamellar liposome and a bleb cell plasma membrane, show that with higher membrane cholesterol the kinetics for vesicular release are decelerated in a concentration dependent manner. This reduction in exocytotic speed was consistent for two observed modes of exocytosis, full and partial release. Partial release events, which only occurred in the bleb cell model due to the higher tension in the system, exhibited amperometric spikes with three distinct shapes. In addition to the classic transient, some spikes displayed a current ramp or plateau following the maximum peak current. These post spike features represent neurotransmitter release from a dilated pore before constriction and show that enhancing membrane rigidity via cholesterol adds resistance to a dilated pore to re-close. This implies that the cholesterol dependent biophysical properties of the membrane directly affect the exocytosis kinetics and that membrane tension along with membrane rigidity can influence the fusion pore dynamics and stabilization which is central to regulation of neurochemical release.
Toward compact and ultra-intense laser-based soft x-ray lasers
NASA Astrophysics Data System (ADS)
Sebban, S.; Depresseux, A.; Oliva, E.; Gautier, J.; Tissandier, F.; Nejdl, J.; Kozlova, M.; Maynard, G.; Goddet, J. P.; Tafzi, A.; Lifschitz, A.; Kim, H. T.; Jacquemot, S.; Rousseau, P.; Zeitoun, P.; Rousse, A.
2018-01-01
We report here recent work on an optical field ionized (OFI), high-order harmonic-seeded EUV laser. The amplifying medium is a plasma of nickel-like krypton obtained by OFI when focusing a 1 J, 30 fs, circularly-polarized, infrared pulse into a krypton-filled gas cell or krypton gas jet. The lasing transition is the 3d94d (J = 0) → 3d94p (J = 1) transition of Ni-like krypton ions at 32.8 nm and is pumped by collisions with hot electrons. The gain dynamics was probed by seeding the amplifier with a high-order harmonic pulse at different delays. The gain duration monotonically decreased from 7 ps to an unprecedented shortness of 450 fs full width at half-maximum as the amplification peak rose from 150 to 1200 with an increase of the plasma density from 3 × 1018 to 1.2 × 1020 cm-3. The integrated energy of the EUV laser pulse was also measured, and found to be around 2 μJ. It is to be noted that in the ASE mode, longer amplifiers were achieved (up to 2 cm), yielding EUV outputs up to 14 μJ.
Gyrokinetic GDC turbulence simulations: confirming a new instability regime in LAPD plasmas
NASA Astrophysics Data System (ADS)
Pueschel, M. J.; Rossi, G.; Told, D.; Terry, P. W.; Jenko, F.; Carter, T. A.
2016-10-01
Recent high-beta experiments at the LArge Plasma Device have found significant parallel magnetic fluctuations in the region of large pressure gradients. Linear gyrokinetic simulations show the dominant instability at these radii to be the gradient-driven drift coupling (GDC) mode, a non-textbook mode driven by pressure gradients and destabilized by the coupling of ExB and grad-B∥ drifts. Unlike in previous studies, the large parallel extent of the device allows for finite-kz versions of this instability in addition to kz = 0 . The locations of maximum linear growth match very well with experimentally observed peaks of B∥ fluctuations. Local nonlinear simulations reproduce many features of the observations fairly well, with the exception of Bperp fluctuations, for which experimental profiles suggest a source unrelated to pressure gradients. In toto, the results presented here show that turbulence and transport in these experiments are driven by the GDC instability, that important characteristics of the linear instability carry over to nonlinear simulations, and - in the context of validation - that the gyrokinetic framework performs surprisingly well far outside its typical area of application, increasing confidence in its predictive abilities. Supported by U.S. DOE.
Meena, Jagan Singh; Chu, Min-Ching; Kuo, Shiao-Wei; Chang, Feng-Chih; Ko, Fu-Hsiang
2010-03-20
We have used a sol-gel spin-coating process to fabricate a new metal-insulator-metal (MIM) capacitor comprising a 10 nm-thick high-k thin dielectric HfO(2) film on a flexible polyimide (PI) substrate. The surface morphology of this HfO(2) film was investigated using atomic force microscopy and scanning electron microscopy, which confirmed that continuous and crack-free film growth had occurred on the film surface. After oxygen (O(2)) plasma pretreatment and subsequent annealing at 250 degrees C, the film on the PI substrate exhibited a low leakage current density of 3.64 x 10(-9) A cm(-2) at 5 V and a maximum capacitance density of 10.35 fF microm(-2) at 1 MHz. The as-deposited sol-gel film was completely oxidized when employing O(2) plasma at a relatively low temperature (ca. 250 degrees C), thereby enhancing the electrical performance. We employed X-ray photoelectron spectroscopy (XPS) at both high and low resolution to examine the chemical composition of the film subjected to various treatment conditions. The shift of the XPS peaks towards higher binding energy, revealed that O(2) plasma treatment was the most effective process for the complete oxidation of hafnium atoms at low temperature. A study of the insulator properties indicated the excellent bendability of our MIM capacitor; the flexible PI substrate could be bent up to 10(5) times and folded to near 360 degrees without any deterioration in its electrical performance.
Niemi, M; Neuvonen, P J; Kivistö, K T
2001-07-01
Our objective was to study the effects of the macrolide antibiotic clarithromycin on the pharmacokinetics and pharmacodynamics of repaglinide, a novel short-acting antidiabetic drug. In a randomized, double-blind, 2-phase crossover study, 9 healthy volunteers were treated for 4 days with 250 mg oral clarithromycin or placebo twice daily. On day 5 they received a single dose of 250 mg clarithromycin or placebo, and 1 hour later a single dose of 0.25 mg repaglinide was given orally. Plasma repaglinide, serum insulin, and blood glucose concentrations were measured up to 7 hours. Clarithromycin increased the mean total area under the concentration-time curve of repaglinide by 40% (P <.0001) and the peak plasma concentration by 67% (P <.005) compared with placebo. The mean elimination half-life of repaglinide was prolonged from 1.4 to 1.7 hours (P <.05) by clarithromycin. Clarithromycin increased the mean incremental area under the concentration-time curve from 0 to 3 hours of serum insulin by 51% (P <.05) and the maximum increase in the serum insulin concentration by 61% (P <.01) compared with placebo. No statistically significant differences were found in the blood glucose concentrations between the placebo and clarithromycin phases. Even low doses of the cytochrome P4503A4 (CYP3A4) inhibitor clarithromycin increase the plasma concentrations and effects of repaglinide. Concomitant use of clarithromycin or other potent inhibitors of CYP3A4 with repaglinide may enhance its blood glucose-lowering effect and increase the risk of hypoglycemia.
Azzini, E; Bugianesi, R; Romano, F; Di Venere, D; Miccadei, S; Durazzo, A; Foddai, M S; Catasta, G; Linsalata, V; Maiani, G
2007-05-01
The current growing interest for natural antioxidants has led to a renewed scientific attention for artichoke, due not only to its nutritional value, but, overall, to its polyphenolic content, showing strong antioxidant properties. The major constituents of artichoke extracts are hydroxycinnamic acids such as chlorogenic acid, dicaffeoylquinic acids caffeic acid and ferulic acid, and flavonoids such as luteolin and apigenin glycosides. In vitro studies, using cultured rat hepatocytes, have shown its hepatoprotective functions and in vivo studies have shown the inhibition of cholesterol biosynthesis in human subjects. Several studies have shown the effect on animal models of artichoke extracts, while information on human bioavailability and metabolism of hydroxycinnamates derivatives is still lacking. Results showed a plasma maximum concentration of 6.4 (SD 1.8) ng/ml for chlorogenic acid after 1 h and its disappearance within 2 h (P< 0.05). Peak plasma concentrations of 19.5 (SD 6.9) ng/ml for total caffeic acid were reached within 1 h, while ferulic acid plasma concentrations showed a biphasic profile with 6.4 (SD1.5) ng/ml and 8.4 (SD4.6) ng/ml within 1 h and after 8 h respectively. We observed a significant increase of dihydrocaffeic acid and dihydroferulic acid total levels after 8 h (P<0.05). No circulating plasma levels of luteolin and apigenin were present. Our study confirms the bioavailability of metabolites of hydroxycinnamic acids after ingestion of cooked edible Cynara scolymus L. (cultivar Violetto di Provenza).
Shin, Chang Yell; Kim, Hae-Sun; Cha, Kwang-Ho; Won, Dong Han; Lee, Ji-Yun; Jang, Sun Woo; Sohn, Uy Dong
2018-05-01
A previous study in humans demonstrated the sustained inhibitory effects of donepezil on acetylcholinesterase (AChE) activity; however, the effective concentration of donepezil in humans and animals is unclear. This study aimed to characterize the effective concentration of donepezil on AChE inhibition and impaired learning and memory in rodents. A pharmacokinetic study of donepezil showed a mean peak plasma concentration of donepezil after oral treatment (3 and 10 mg/kg) of approximately 1.2 ± 0.4 h and 1.4 ± 0.5 h, respectively; absolute bioavailability was calculated as 3.6%. Further, AChE activity was inhibited by increasing plasma concentrations of donepezil, and a maximum inhibition of 31.5 ± 5.7% was observed after donepezil treatment in hairless rats. Plasma AChE activity was negatively correlated with plasma donepezil concentration. The pharmacological effects of donepezil are dependent upon its concentration and AChE activity; therefore, we assessed the effects of donepezil on learning and memory using a Y-maze in mice. Donepezil treatment (3 mg/kg) significantly prevented the progression of scopolamine-induced memory impairment in mice. As the concentration of donepezil in the brain increased, the recovery of spontaneous alternations also improved; maximal improvement was observed at 46.5 ± 3.5 ng/g in the brain. In conclusion, our findings suggest that the AChE inhibitory activity and pharmacological effects of donepezil can be predicted by the concentration of donepezil. Further, 46.5 ± 3.5 ng/g donepezil is an efficacious target concentration in the brain for treating learning and memory impairment in rodents.
German, Polina; Mathias, Anita; Brainard, Diana; Kearney, Brian P
2016-11-01
Ledipasvir/sofosbuvir (Harvoni ® ), a fixed-dose combination tablet of an NS5A inhibitor ledipasvir and an NS5B polymerase inhibitor sofosbuvir, is approved in the US, European Union, Canada, and other regions for the treatment of chronic hepatitis C virus infection in adults. Following absorption, ledipasvir reaches maximum plasma concentrations (T max ) 4-4.5 h post-dose and is eliminated with a terminal half-life (t 1/2 ) of 47 h. Sofosbuvir undergoes intracellular activation to an active triphosphate GS-461203 (not detected in plasma) and ultimately to GS-331007, a predominant circulating metabolite, which is the primary analyte of interest in clinical pharmacology studies. Sofosbuvir is rapidly absorbed and eliminated from plasma (T max : 0.8-1 h; t 1/2 : 0.5 h). The peak plasma concentrations for GS-331007 are achieved between 3.5 and 4 h post-dose; the elimination t 1/2 for GS-331007 is 27 h. Ledipasvir/sofosbuvir exhibits a favorable clinical pharmacology profile; it can be administered once daily without regard to food and does not require dose modification in hepatitis C virus-infected patients with any degree of hepatic impairment or mild to moderate renal impairment. The pharmacokinetic profiles of ledipasvir, sofosbuvir, and GS-331007 (predominant circulating metabolite of sofosbuvir) are not significantly affected by demographic variables; pharmacokinetic/pharmacodynamic analyses reveal no exposure-response relationships for efficacy or safety. The review summarizes the clinical pharmacokinetics, pharmacodynamics, and pharmacokinetic/pharmacodynamic analyses for ledipasvir/sofosbuvir.
Waltemeyer, S.D.
1995-01-01
A sediment-transport model to simulate channel change was applied to a 1-mile reach of Cuchillo Negro Creek at the Interstate 25 crossing at Truth or Consequences, New Mexico, using the Bridge-Stream Tube model for Alluvial River Simulation (BRI-STARS). The 500-year flood discharge was estimated to be 10,700 cubic feet per second. The 100-year, 500-year, and regional maximum discharges were used to design synthetic and discretized hydrographs using a flood volume equation. The regional maximum discharge relation was developed for New Mexico based on 259 streamflow-gaging stations' maximum peak discharge. The regional maximum-peak discharge for the site was determined to be 81,700 cubic feet per second. Bed-material particle-size distribution was determined for six size classes ranging from 1 to 30 millimeters. The median diameter was 4.6 millimeters at the bed surface and 9.0 millimeters 13 feet below the bed surface. Bed-material discharge for use in the model was estimated to be 18,770 tons per day using hydraulic properties, water temperature, and Yang's gravel equation. Channel-change simulations showed a maximum channel degradation of 1.38 feet for the regional maximum-peak discharge hydrograph.
A Study of the Response of the Human Cadaver Head to Impact
Hardy, Warren N.; Mason, Matthew J.; Foster, Craig D.; Shah, Chirag S.; Kopacz, James M.; Yang, King H.; King, Albert I.; Bishop, Jennifer; Bey, Michael; Anderst, William; Tashman, Scott
2008-01-01
High-speed biplane x-ray and neutral density targets were used to examine brain displacement and deformation during impact. Relative motion, maximum principal strain, maximum shear strain, and intracranial pressure were measured in thirty-five impacts using eight human cadaver head and neck specimens. The effect of a helmet was evaluated. During impact, local brain tissue tends to keep its position and shape with respect to the inertial frame, resulting in relative motion between the brain and skull and deformation of the brain. The local brain motions tend to follow looping patterns. Similar patterns are observed for impact in different planes, with some degree of posterior-anterior and right-left symmetry. Peak coup pressure and pressure rate increase with increasing linear acceleration, but coup pressure pulse duration decreases. Peak average maximum principal strain and maximum shear are on the order of 0.09 for CFC 60 Hz data for these tests. Peak average maximum principal strain and maximum shear increase with increasing linear acceleration, coup pressure, and coup pressure rate. Linear and angular acceleration of the head are reduced with use of a helmet, but strain increases. These results can be used for the validation of finite element models of the human head. PMID:18278591
NASA Astrophysics Data System (ADS)
Apollonov, V. V.; Derzhavin, S. I.; Kazakov, K. Kh
1993-02-01
A source of hard x radiation based on a laser plasma has been studied under conditions such that parametric instabilities are driven in the plasma at low intensities of the pump radiation (below 10 GW/cm2). A qualitative interpretation of the observed effects is offered.
Iogenic Plasma and its Rotation-Driven Transport in Jupiter's Magnetosphere
NASA Technical Reports Server (NTRS)
Smyth, William H.
2001-01-01
Model calculations are reported for the Iogenic plasma source created by atomic oxygen and sulfur above Io's exobase in the corona and extended clouds (Outer Region). On a circumplanetary scale, two-dimensional distributions produced by integrating the proper three dimensional rate information for electron impact and charge exchange processes along the magnetic field lines are presented for the pickup ion rates, the net-mass and total-mass loading rates, the mass per unit magnetic flux rate, the pickup conductivity, the radial pickup current, and the net-energy loading rate for the plasma torus. All of the two-dimensional distributions are highly peaked at Io's location and hence highly asymmetric about Jupiter. The Iogenic plasma source is also calculated on a much smaller near-Io scale to investigate the structure of the highly peak rates centered about lo's instantaneous location. The Iogenic plasma source for the Inner Region (pickup rates produced below Io's exobase) is, however, expected to be the dominant source near lo for the formation of the plasma torus ribbon and to be a comparable source, if not a larger contributor, to the energy budget of the plasma torus, so as to provide the necessary power to sustain the plasma torus radiative loss rate.
Petzinger, C; Larner, C; Heatley, J J; Bailey, C A; MacFarlane, R D; Bauer, J E
2014-04-01
The effect of α-linolenic acid from a flaxseed (FLX)-enriched diet on plasma lipid and fatty acid metabolism and possible atherosclerosis risk factors was studied in Monk parrots (Myiopsitta monachus). Twenty-four Monk parrots were randomly assigned to diets containing either 10% ground SUNs or 10% ground FLXs. Feed intake was calculated daily. Blood samples, body condition scores and body weights were obtained at -5 weeks, day 0, 7, 14, 28, 42 and 70. Plasma samples were analysed for total cholesterol, free cholesterol, triacylglycerols and lipoproteins. Phospholipid subfraction fatty acid profiles were determined. By day 70, the FLX group had significantly higher plasma phospholipid fatty acids including 18:3n-3 (α-linolenic acid), 20:5n-3 (eicosapentaenoic acid) and 22:6n-3 (docosahexaenoic acid). The sunflower group had significantly higher plasma phospholipid levels of 20:4n-6 (arachidonic acid). By day 70, the high-density lipoprotein (HDL) peak shifted resulting in significantly different HDL peak densities between the two experimental groups (1.097 g/ml FLX group and 1.095 g/ml SUN group, p = 0.028). The plasma fatty acid results indicate that Monk parrots can readily convert α-linolenic acid to the long-chain omega-3 derivatives including docosahexaenoic acid and reduce 20:4n-6 accumulation in plasma phospholipids. The reason for a shift in the HDL peak density is unknown at this time. Journal of Animal Physiology and Animal Nutrition © 2013 Blackwell Verlag GmbH.
Lenzuni, Paolo
2015-07-01
The purpose of this article is to develop a method for the statistical inference of the maximum peak sound pressure level and of the associated uncertainty. Both quantities are requested by the EU directive 2003/10/EC for a complete and solid assessment of the noise exposure at the workplace. Based on the characteristics of the sound pressure waveform, it is hypothesized that the distribution of the measured peak sound pressure levels follows the extreme value distribution. The maximum peak level is estimated as the largest member of a finite population following this probability distribution. The associated uncertainty is also discussed, taking into account not only the contribution due to the incomplete sampling but also the contribution due to the finite precision of the instrumentation. The largest of the set of measured peak levels underestimates the maximum peak sound pressure level. The underestimate can be as large as 4 dB if the number of measurements is limited to 3-4, which is common practice in occupational noise assessment. The extended uncertainty is also quite large (~2.5 dB), with a weak dependence on the sampling details. Following the procedure outlined in this article, a reliable comparison between the peak sound pressure levels measured in a workplace and the EU directive action limits is possible. Non-compliance can occur even when the largest of the set of measured peak levels is several dB below such limits. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
NASA Astrophysics Data System (ADS)
Sydorenko, Dmytro
2015-11-01
Electrons emitted by electrodes surrounding or immersed in the plasma are accelerated by the sheath electric field and become electron beams penetrating the plasma. In plasma applications where controlling the electron velocity distribution function (EVDF) is crucial, these beams are an important factor capable of modifying the EVDF and affecting the discharge properties. Recently, it was reported that an EVDF measured in a dc-rf discharge with 800 V dc voltage has not only a peak of 800 eV electrons emitted from the dc-biased electrode, but also a peak of suprathermal electrons with energy up to several hundred eV. Initial explanation of the suprathermal peak suggested that the fast long plasma waves excited by the beam decay parametrically into ion acoustic waves and short plasma waves with much lower phase velocity which accelerate bulk electrons to suprathermal energies. Particle-in-cell simulation of a dc beam-plasma system, however, reveals that the short waves appear not due to the parametric instability, but due to the plasma nonuniformity. Moreover, the acceleration may occur in two stages. Plasma waves excited by the beam in the middle of the system propagate towards the anode and enter the density gradient area where their wavelength and phase speed rapidly decrease. Acceleration of thermal electrons by these waves is the first stage. Some of the accelerated electrons reflect from the anode sheath, travel through the plasma, reflect near the cathode, and enter the accelerating area again but with the energy higher than before. The acceleration that occurs now is the second stage. The energy of a particle after the second acceleration exceeds the initial thermal energy by an order of magnitude. This two-stage mechanism plays a role in explaining previous observations of energetic suprathermal electrons in similar discharges. The study is performed in collaboration with I. D. Kaganovich (PPPL), P. L. G. Ventzek and L. Chen (Tokyo Electron America).
Wada, Morito; Kitayama, Masato; Hashimoto, Hiroshi; Kudo, Tsuyoshi; Kudo, Mihoko; Takada, Norikazu; Hirota, Kazuyoshi
2012-01-01
A rectus sheath block can provide postoperative analgesia for midline incisions. However, information regarding the pharmacokinetics of local anesthetics used in this block is lacking. In this study, we detail the time course of ropivacaine concentrations after this block. Thirty-nine patients undergoing elective lower abdominal surgery were assigned to 3 groups receiving rectus sheath block with 20 mL of different concentrations of ropivacaine. Peak plasma concentrations were dose dependent, and there were no significant differences in the times to peak plasma concentrations. The present data also suggested a slower absorption kinetics profile for ropivacaine after rectus sheath block than other compartment blocks.
Time-resolved imaging of the plasma development in a triggered vacuum switch
NASA Astrophysics Data System (ADS)
Park, Wung-Hoa; Kim, Moo-Sang; Son, Yoon-Kyoo; Frank, Klaus; Lee, Byung-Joon; Ackerman, Thilo; Iberler, Marcus
2017-12-01
Triggered vacuum switches (TVS) are particularly used in pulsed power technology as closing switches for high voltages and high charge transfer. A non-sealed-off prototype was designed with a side-on quartz window to investigate the evolution of the trigger discharge into the main discharge. The image acquisition was done with a fast CCD camera PI-MAX2 from Princeton Instruments. The CCD camera has a maximum exposure time of 2 ns. The electrode configuration of the prototype is a conventional six-rod gap type, a capacitor bank with C = 16.63 μF, which corresponds at 20 kV charging voltage to a total stored charge of 0.3 C or a total energy of 3.3 kJ. The peak current is 88 kA. According to the tremendously highly different light intensities during the trigger and main discharge, the complete discharge is split into three phases: a trigger breakdown phase, an intermediate phase and a main discharge phase. The CCD camera images of the first phase show instabilities of the trigger breakdown, in phase 2 three different discharge modes are observed. After the first current maximum the discharge behavior is reproducible.
NASA Astrophysics Data System (ADS)
Dedrick, J.; Boswell, R. W.; Charles, C.
2010-09-01
Barrier discharges are a proven method of generating plasmas at high pressures, having applications in industrial processing, materials science and aerodynamics. In this paper, we present new measurements of an asymmetric surface barrier discharge plasma driven by pulsed radio frequency (rf 13.56 MHz) power in atmospheric pressure air. The voltage, current and optical emission of the discharge are measured temporally using 2.4 kVp-p (peak to peak) 13.56 MHz rf pulses, 20 µs in duration. The results exhibit different characteristics to plasma actuators, which have similar discharge geometry but are typically driven at frequencies of up to about 10 kHz. However, the electrical measurements are similar to some other atmospheric pressure, rf capacitively coupled discharge systems with symmetric electrode configurations and different feed gases.
NASA Astrophysics Data System (ADS)
Deepak, G. Divya; Joshi, N. K.; Prakash, Ram
2018-05-01
In this study, both model analysis and electrical characterization of a dielectric barrier discharge based argon plasma jet have been carried at atmospheric pressure in a pin electrode configuration. The plasma and fluid dynamics modules of COMSOL multi-physics code have been used for the modeling of the plasma jet. The plasma parameters, such as, electron density, electron temperature and electrical potential have been analyzed with respect to the electrical parameters, i.e., supply voltage and supply frequency with and without the flow of gas. In all the experiments, gas flow rate has been kept constant at 1 liter per minute. This electrode configuration is subjected to a range of supply frequencies (10-25 kHz) and supply voltages (3.5-6.5 kV). The power consumed by the device has been estimated at different applied combinations (supply voltage & frequency) for optimum power consumption at maximum jet length. The maximum power consumed by the device in this configuration for maximum jet length of ˜26 mm is just ˜1 W.
Reyes, Alvaro; Castillo, Adrián; Castillo, Javiera; Cornejo, Isabel
2018-05-01
To compare the effects of an inspiratory versus and expiratory muscle-training program on voluntary and reflex peak cough flow in patients with Parkinson disease. A randomized controlled study. Home-based training program. In all, 40 participants with diagnosis of Parkinson's disease were initially recruited in the study and randomly allocated to three study groups. Of them, 31 participants completed the study protocol (control group, n = 10; inspiratory training group, n = 11; and expiratory training group, n = 10) Intervention: The inspiratory and expiratory group performed a home-based inspiratory and expiratory muscle-training program, respectively (five sets of five repetitions). Both groups trained six times a week for two months using a progressively increased resistance. The control group performed expiratory muscle training using the same protocol and a fixed resistance. Spirometric indices, maximum inspiratory pressure, maximum expiratory pressure, and peak cough flow during voluntary and reflex cough were assessed before and at two months after training. The magnitude of increase in maximum expiratory pressure ( d = 1.40) and voluntary peak cough flow ( d = 0.89) was greater for the expiratory muscle-training group in comparison to the control group. Reflex peak cough flow had a moderate effect ( d = 0.27) in the expiratory group in comparison to the control group. Slow vital capacity ( d = 0.13) and forced vital capacity ( d = 0.02) had trivial effects in the expiratory versus the control group. Two months of expiratory muscle-training program was more beneficial than inspiratory muscle-training program for improving maximum expiratory pressure and voluntary peak cough flow in patients with Parkinson's disease.
Schmidt, J; Winnerl, S; Seidel, W; Bauer, C; Gensch, M; Schneider, H; Helm, M
2015-06-01
We demonstrate a system for picking of mid-infrared and terahertz (THz) radiation pulses from the free-electron laser (FEL) FELBE operating at a repetition rate of 13 MHz. Single pulses are reflected by a dense electron-hole plasma in a Ge slab that is photoexcited by amplified near-infrared (NIR) laser systems operating at repetition rates of 1 kHz and 100 kHz, respectively. The peak intensity of picked pulses is up to 400 times larger than the peak intensity of residual pulses. The required NIR fluence for picking pulses at wavelengths in the range from 5 μm to 30 μm is discussed. In addition, we show that the reflectivity of the plasma decays on a time scale from 100 ps to 1 ns dependent on the wavelengths of the FEL and the NIR laser. The plasma switch enables experiments with the FEL that require high peak power but lower average power. Furthermore, the system is well suited to investigate processes with decay times in the μs to ms regime, i.e., much longer than the 77 ns long pulse repetition period of FELBE.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schmidt, J., E-mail: j.schmidt@hzdr.de; Helm, M.; Technische Universität Dresden, 01062 Dresden
2015-06-15
We demonstrate a system for picking of mid-infrared and terahertz (THz) radiation pulses from the free-electron laser (FEL) FELBE operating at a repetition rate of 13 MHz. Single pulses are reflected by a dense electron-hole plasma in a Ge slab that is photoexcited by amplified near-infrared (NIR) laser systems operating at repetition rates of 1 kHz and 100 kHz, respectively. The peak intensity of picked pulses is up to 400 times larger than the peak intensity of residual pulses. The required NIR fluence for picking pulses at wavelengths in the range from 5 μm to 30 μm is discussed. Inmore » addition, we show that the reflectivity of the plasma decays on a time scale from 100 ps to 1 ns dependent on the wavelengths of the FEL and the NIR laser. The plasma switch enables experiments with the FEL that require high peak power but lower average power. Furthermore, the system is well suited to investigate processes with decay times in the μs to ms regime, i.e., much longer than the 77 ns long pulse repetition period of FELBE.« less
NASA Technical Reports Server (NTRS)
Armstrong, G. P.; Carlier, S. G.; Fukamachi, K.; Thomas, J. D.; Marwick, T. H.
1999-01-01
OBJECTIVES: To validate a simplified estimate of peak power (SPP) against true (invasively measured) peak instantaneous power (TPP), to assess the feasibility of measuring SPP during exercise and to correlate this with functional capacity. DESIGN: Development of a simplified method of measurement and observational study. SETTING: Tertiary referral centre for cardiothoracic disease. SUBJECTS: For validation of SPP with TPP, seven normal dogs and four dogs with dilated cardiomyopathy were studied. To assess feasibility and clinical significance in humans, 40 subjects were studied (26 patients; 14 normal controls). METHODS: In the animal validation study, TPP was derived from ascending aortic pressure and flow probe, and from Doppler measurements of flow. SPP, calculated using the different flow measures, was compared with peak instantaneous power under different loading conditions. For the assessment in humans, SPP was measured at rest and during maximum exercise. Peak aortic flow was measured with transthoracic continuous wave Doppler, and systolic and diastolic blood pressures were derived from brachial sphygmomanometry. The difference between exercise and rest simplified peak power (Delta SPP) was compared with maximum oxygen uptake (VO(2)max), measured from expired gas analysis. RESULTS: SPP estimates using peak flow measures correlated well with true peak instantaneous power (r = 0.89 to 0.97), despite marked changes in systemic pressure and flow induced by manipulation of loading conditions. In the human study, VO(2)max correlated with Delta SPP (r = 0.78) better than Delta ejection fraction (r = 0.18) and Delta rate-pressure product (r = 0.59). CONCLUSIONS: The simple product of mean arterial pressure and peak aortic flow (simplified peak power, SPP) correlates with peak instantaneous power over a range of loading conditions in dogs. In humans, it can be estimated during exercise echocardiography, and correlates with maximum oxygen uptake better than ejection fraction or rate-pressure product.
NASA Astrophysics Data System (ADS)
Biskup, B.; Maszl, C.; Breilmann, W.; Held, J.; Böke, M.; Benedikt, J.; von Keudell, A.
2018-03-01
High power impulse magnetron sputtering (HiPIMS) discharges are an excellent tool for deposition of thin films with superior properties. By adjusting the plasma parameters, an energetic metal and reactive species growth flux can be controlled. This control requires, however, a quantitative knowledge of the ion-to-neutral ratio in the growth flux and of the ion energy distribution function to optimize the deposited energy per incorporated atom in the film. This quantification is performed by combining two diagnostics, a quartz crystal microbalance (QCM) combined with an ion-repelling grid system (IReGS) to discriminate ions versus neutrals and a HIDEN EQP plasma monitor to measure the ion energy distribution function (IEDF). This approach yields the ionized metal flux fraction (IMFF) as the ionization degree in the growth flux. This is correlated to the plasma performance recorded by time resolved ICCD camera measurements, which allow to identify the formation of pronounced ionization zones, so called spokes, in the HiPIMS plasma. Thereby an automatic technique was developed to identify the spoke mode number. The data indicates two distinct regimes with respect to spoke formation that occur with increasing peak power, a stochastic regime with no spokes at low peak powers followed by a regime with distinct spokes at varying mode numbers at higher peak powers. The IMFF increases with increasing peak power reaching values of almost 80% at very high peak powers. The transition in between the two regimes coincides with a pronounced change in the IMFF. This change indicates that the formation of spokes apparently counteracts the return effect in HiPIMS. Based on the IMFF and the mean energy of the ions, the energy per deposited atom together with the overall energy flux onto the substrate is calculated. This allows us to determine an optimum for the peak power density around 0.5 kW cm-2 for chromium HiPIMS.
Etude Spectroscopique des Surfaces des Couches Minces de Silicium Amorphe Hydrogene
NASA Astrophysics Data System (ADS)
Bekkay, Touhami
In this work, we have studied the surface of hydrogenated a-Si and phosphorous doped a-Si:H,P. Due to the presence of unstable dangling bonds, these films are oxidized in the air after their preparation. XPS and UPS have been used to study these oxidized surfaces before and after plasma sputtering and wet chemical cleaning. We used deconvolution technique for the analysis of the spectra. First, the composition of a-Si:H films, prepared by plasma deposition at various power levels, has been determined by XPS. It has been found that films deposited using 5 W power contain SiH_4 molecules. This is confirmed by IR measurements. These molecules have not been seen in films prepared with a plasma power above 5 W. The XPS spectra of the surface oxide, before and after 3 keV sputtering by argon show that is impossible to completely remove these surface oxide ions. During sputtering, some oxygen atoms are forward scattered into the silicon substrat and form new oxidation states. UPS has been used to study the valence bands of the oxidized surfaces before and after HF cleaning. Prior to a chemical etch, the valence band analysis of the native SiO_2 indicates the presence of three O(2p) orbitals, in agreement with theory. Two are non-bonding orbitals and the third is associated with weak bonding to Si(3p). Two other orbitals have been identified at 10 eV and 11.8 eV. They correspond to O(2p)-Si(3p) and O(2p)-Si(3s) bonds respectively. A residual film containing -SiH, -SiO, SiOH and non-bonding orbitals has been found, after HF cleaning. A series of a-Si:H films have been doped with phosphine (PH_3). Their corresponding XPS spectra around 130 eV are dominated by the surface and bulk plasmon peaks. Numerical filtering has been used to distinguish between the phosphorous P(2p) peak located at 129.5 eV and the phosphorous oxide peak located at 134 eV. The increase in the intensity of these peaks as the (PH_3) increases indicates that a certain proportion of phosphorous is incorporated into the Si matrix and that the rest is oxidized. The shifts of the bulk Fermi level, E_{rm F}, and the surface Fermi level, E _{rm FS}, vary linearly with (PH_3). The difference between these two straight lines give the potential responsible for the bulk band bending. Close to the surface, the band bending is deduced by varying the detection angle in XPS measurements; a maximum value of 0.2 eV has been found in a depth range of 38 A to 105 A.
Waltemeyer, Scott D.
2008-01-01
Estimates of the magnitude and frequency of peak discharges are necessary for the reliable design of bridges, culverts, and open-channel hydraulic analysis, and for flood-hazard mapping in New Mexico and surrounding areas. The U.S. Geological Survey, in cooperation with the New Mexico Department of Transportation, updated estimates of peak-discharge magnitude for gaging stations in the region and updated regional equations for estimation of peak discharge and frequency at ungaged sites. Equations were developed for estimating the magnitude of peak discharges for recurrence intervals of 2, 5, 10, 25, 50, 100, and 500 years at ungaged sites by use of data collected through 2004 for 293 gaging stations on unregulated streams that have 10 or more years of record. Peak discharges for selected recurrence intervals were determined at gaging stations by fitting observed data to a log-Pearson Type III distribution with adjustments for a low-discharge threshold and a zero skew coefficient. A low-discharge threshold was applied to frequency analysis of 140 of the 293 gaging stations. This application provides an improved fit of the log-Pearson Type III frequency distribution. Use of the low-discharge threshold generally eliminated the peak discharge by having a recurrence interval of less than 1.4 years in the probability-density function. Within each of the nine regions, logarithms of the maximum peak discharges for selected recurrence intervals were related to logarithms of basin and climatic characteristics by using stepwise ordinary least-squares regression techniques for exploratory data analysis. Generalized least-squares regression techniques, an improved regression procedure that accounts for time and spatial sampling errors, then were applied to the same data used in the ordinary least-squares regression analyses. The average standard error of prediction, which includes average sampling error and average standard error of regression, ranged from 38 to 93 percent (mean value is 62, and median value is 59) for the 100-year flood. The 1996 investigation standard error of prediction for the flood regions ranged from 41 to 96 percent (mean value is 67, and median value is 68) for the 100-year flood that was analyzed by using generalized least-squares regression analysis. Overall, the equations based on generalized least-squares regression techniques are more reliable than those in the 1996 report because of the increased length of record and improved geographic information system (GIS) method to determine basin and climatic characteristics. Flood-frequency estimates can be made for ungaged sites upstream or downstream from gaging stations by using a method that transfers flood-frequency data at the gaging station to the ungaged site by using a drainage-area ratio adjustment equation. The peak discharge for a given recurrence interval at the gaging station, drainage-area ratio, and the drainage-area exponent from the regional regression equation of the respective region is used to transfer the peak discharge for the recurrence interval to the ungaged site. Maximum observed peak discharge as related to drainage area was determined for New Mexico. Extreme events are commonly used in the design and appraisal of bridge crossings and other structures. Bridge-scour evaluations are commonly made by using the 500-year peak discharge for these appraisals. Peak-discharge data collected at 293 gaging stations and 367 miscellaneous sites were used to develop a maximum peak-discharge relation as an alternative method of estimating peak discharge of an extreme event such as a maximum probable flood.
Simulation study of the sub-terawatt laser wakefield acceleration operated in self-modulated regime
NASA Astrophysics Data System (ADS)
Hsieh, C.-Y.; Lin, M.-W.; Chen, S.-H.
2018-02-01
Laser wakefield acceleration (LWFA) can be accomplished by introducing a sub-terawatt (TW) laser pulse into a thin, high-density gas target. In this way, the self-focusing effect and the self-modulation that happened on the laser pulse produce a greatly enhanced laser peak intensity that can drive a nonlinear plasma wave to accelerate electrons. A particle-in-cell model is developed to study sub-TW LWFA when a 0.6-TW laser pulse interacts with a dense hydrogen plasma. Gas targets having a Gaussian density profile or a flat-top distribution are defined for investigating the properties of sub-TW LWFA when conducting with a gas jet or a gas cell. In addition to using 800-nm laser pulses, simulations are performed with 1030-nm laser pulses, as they represent a viable approach to realize the sub-TW LWFA driven by high-frequency, diode-pumped laser systems. The peak density which allows the laser peak power PL˜2 Pc r of self-focusing critical power is favourable for conducting sub-TW LWFA. Otherwise, an excessively high peak density can induce an undesired filament effect which rapidly disintegrates the laser field envelope and violates the process of plasma wave excitation. The plateau region of a flat-top density distribution allows the self-focusing and the self-modulation of the laser pulse to develop, from which well-established plasma bubbles can be produced to accelerate electrons. The process of electron injection is complicated in such high-density plasma conditions; however, increasing the length of the plateau region represents a straightforward method to realize the injection and acceleration of electrons within the first bubble, such that an improved LWFA performance can be accomplished.
20 kA PFN capacitor bank with solid-state switching. [pulse forming network for plasma studies
NASA Technical Reports Server (NTRS)
Posta, S. J.; Michels, C. J.
1973-01-01
A compact high-current pulse-forming network capacitor bank using paralleled silicon controlled rectifiers as switches is described. The maximum charging voltage of the bank is 1kV and maximum load current is 20 kA. The necessary switch equalization criteria and performance with dummy load and an arc plasma generator are described.
NASA Astrophysics Data System (ADS)
Yan, Wen; Economou, Demetre J.
2017-10-01
A 2D (axisymmetric) computational study of the discharge characteristics of an atmospheric pressure plasma jet as a function of gas flow rate was performed. The helium jet emerged from a dielectric tube, with an average gas flow velocity in the range 2.5-20 m s-1 (1 atm, 300 K) in a nitrogen ambient, and impinged on a substrate a short distance dowstream. The effect of the substrate conductivity (conductror versus insulator) was also studied. Whenever possible, simulation predictions were compared with published experimental observations. Discharge ignition and propagation in the dielectric tube were hardly affected by the He gas flow velocity. Most properties of the plasma jet, however, depended sensitively on the He gas flow velocity, which determined the concentration distributions of helium and nitrogen in the mixing layer forming in the gap between the tube exit and the substrate. At low gas flow velocity, the plasma jet evolved from a hollow (donut-shaped) feature to one where the maximum of electron density was on axis. When the gas flow velocity was high, the plasma jet maintained its hollow structure until it struck the substrate. For a conductive substrate, the radial ion fluxes to the surface were relatively uniform over a radius of ~0.4-0.8 mm, and the dominant ion flux was that of He+. For a dielectric substrate, the radial ion fluxes to the surface peaked on the symmetry axis at low He gas flow velocity, but a hollow ion flux distribution was observed at high gas flow velocity. At the same time, the main ion flux switched from N2+ to He2+ as the He gas flow velocity increased from a low to a high value. The diameter of the plasma ‘footprint’ on the substrate first increased with increasing He gas flow velocity, and eventually saturated with further increases in velocity.
Menge, M; Rose, M; Bohland, C; Zschiesche, E; Kilp, S; Metz, W; Allan, M; Röpke, R; Nürnberger, M
2012-12-01
The pharmacokinetics of tildipirosin (Zuprevo(®) 180 mg/mL solution for injection for cattle), a novel 16-membered macrolide for treatment, control, and prevention of bovine respiratory disease, were investigated in studies collecting blood plasma, lung tissue, and in vivo samples of bronchial fluid (BF) from cattle. After single subcutaneous (s.c.) injection at 4 mg/kg body weight, maximum plasma concentration (C(max)) was 0.7 μg/mL. T(max) was 23 min. Mean residence time from the time of dosing to the time of last measurable concentration (MRT(last)) and terminal half-life (T(1/2) ) was 6 and 9 days, respectively. A strong dose-response relationship with no significant sex effect was shown for both C(max) and area under the plasma concentration-time curve from time 0 to the last sampling time with a quantifiable drug concentration (AUC(last) ) over the range of doses up to 6 mg/kg. Absolute bioavailability was 78.9%. The volume of distribution based on the terminal phase (V(z)) was 49.4 L/kg, and the plasma clearance was 144 mL/h/kg. The time-concentration profile of tildipirosin in BF and lung far exceeded those in blood plasma. In lung, tildipirosin concentrations reached 9.2 μg/g at 4 h, peaked at 14.8 μg/g at day 1, and slowly declined to 2.0 μg/g at day 28. In BF, the concentration of tildipirosin reached 1.5 and 3.0 μg/g at 4 and 10 h, maintained a plateau of about 3.5 μg/g between day 1 and 3, and slowly declined to 1.0 at day 21. T(1/2) in lung and BF was approximately 10 and 11 days. Tildipirosin is rapidly and extensively distributed to the respiratory tract followed by slow elimination. © 2011 Blackwell Publishing Ltd.
Neutral and Plasma Sources in the Saturn's Magnetosphere
NASA Astrophysics Data System (ADS)
Jurac, S.; Johnson, R. E.
1999-05-01
The heavy ion plasma in Saturnian inner magnetosphere is derived from the icy satellites and ring particles imbedded in the plasma. Recent Hubble Space Telescope measurements of the densities of neutral OH molecules which co-exist with and are precursors of the plasma ions have constrained models for the plasma sources. Richardson et al (1998) considered all existing HST observations and derived water-like neutral densities and estimated required sources to maintain equilibrium. Their neutral densities show maximum close to Enceladus (where the E-ring density peaks) and their total neutral source rate needed to maintain neutrals in steady state is for an order of magnitude larger than source rate given by Shi et al (1995). We model the sputtering of water-ice using the recently developed Monte-Carlo collisional transport code, and calculate neutral supply rates from sputtering of Enceladus and the E-ring. This collisional code, used previously to evaluate sputtering from the interstellar grains (Jurac et al, 1998) is modified to include electronic processes relevant to water-ice sputtering, and then applied to the E-ring grains. It is shown that the grain erosion rate increases substantially when the ion penetration depth becomes comparable to the grain radius. The sputtering and collection rates for plasma ions and neutrals are evaluated and it is shown that the E-ring might be the dominant source of water-like neutrals in the Saturnian magnetosphere. We also describe competition between grain growth and erosion and discuss implications to the existing E-ring evolutionary models. References: Jurac S., R. E. Johnson, B. Donn; Astroph. J. 503, 247, 1998 Richardson, J. D., A. Eviatar, M. A. McGrath, V. M. Vasyliunas; J. Geophys. Res., 103, 20245, 1998 Shi, M., R.A. Baragiola, D.E. Grosjean, R.E. Johnson, S. Jurac and J. Schou; J. Geophys. Res., 100, 26387, 1995.
Davies, Geraint; Ardrey, Alison; Jave, Oswaldo; López-Romero, Sonia L.; Ward, Stephen A.; Moore, David A. J.
2012-01-01
For drug-compliant patients, poor responses to tuberculosis (TB) treatment might be attributable to subtherapeutic drug concentrations. An impaired absorption of rifampin was previously reported for patients with diabetes mellitus (DM) or HIV. The objectives of this study were to determine whether TB drug pharmacokinetics differed in Peruvian TB patients with DM or HIV. In this cross-sectional study, TB patients, recruited from health centers in Lima, Peru, had blood samples taken at 2 and 6 h after directly observed TB drug ingestion, to determine plasma concentrations of rifampin. Of 105 patients, 50 had TB without a comorbidity, 26 had coexistent DM, and 29 had coexistent HIV. Unexpectedly, the overall median 2- and 6-h levels of rifampin were 1.6 and 3.2 mg/liter, respectively, and the time to the peak concentration was 6 h (slow absorber) instead of 2 h (fast absorber) for 61 patients (62.2%). The geometric mean peak concentration of drug in serum (Cmax) was significantly higher in fast absorbers than in slow absorbers (5.0 versus 3.8 mg/liter; P = 0.05). The rifampin Cmax was significantly lower in male patients than in female patients (3.3 versus 6.3 mg/liter; P < 0.001). Neither slow nor fast absorbers with comorbidities (DM or HIV) had significantly different Cmax results compared to those of TB patients without comorbidities. An analysis of variance regression analysis showed that female gender (P < 0.001) and the time to maximum concentration of drug in serum (Tmax) at 2 h (P = 0.012) were independently correlated with increased exposure to rifampin. Most of this Peruvian study population exhibited rifampin pharmacokinetics different from those conventionally reported, with delayed absorption and low plasma concentrations, independent of the presence of an HIV or DM comorbidity. PMID:22330931
Campbell, Bill; Roberts, Mike; Kerksick, Chad; Wilborn, Colin; Marcello, Brandon; Taylor, Lem; Nassar, Erika; Leutholtz, Brian; Bowden, Rodney; Rasmussen, Chris; Greenwood, Mike; Kreider, Richard
2006-09-01
We evaluated the pharmacokinetics, safety, and efficacy of l-arginine alpha-ketoglutarate (AAKG) in trained adult men. Subjects participated in two studies that employed a randomized, double-blind, controlled design. In study 1, 10 healthy men (30-50 y old) fasted for 8 h and then ingested 4 g of time-released or non-timed-released AAKG. Blood samples were taken for 8 h after AAKG ingestion to assess the pharmacokinetic profile of L-arginine. After 1 wk the alternative supplement was ingested. In study 2, which was placebo controlled, 35 resistance-trained adult men (30-50 y old) were randomly assigned to ingest 4 g of AAKG (three times a day, i.e., 12 g daily, n = 20) or placebo (n = 15). Participants performed 4 d of periodized resistance training per week for 8 wk. At 0, 4, and 8 wk of supplementation the following tests were performed: clinical blood markers, one repetition maximum bench press, isokinetic quadriceps muscle endurance, anaerobic power, aerobic capacity, total body water, body composition, and psychometric parameters tests. Data were analyzed by repeated measures analysis of variance. In study 1, significant differences were observed in plasma arginine levels in subjects taking non-timed-release and timed-release AAKG. In study 2, significant differences were observed in the AAKG group (P < 0.05) for 1RM bench press, Wingate peak power, blood glucose, and plasma arginine. No significant differences were observed between groups in body composition, total body water, isokinetic quadriceps muscle endurance, or aerobic capacity. AAKG supplementation appeared to be safe and well tolerated, and positively influenced 1RM bench press and Wingate peak power performance. AAKG did not influence body composition or aerobic capacity.
NASA Astrophysics Data System (ADS)
Ragozin, Eugene N.; Mednikov, Konstantin N.; Pertsov, Andrei A.; Pirozhkov, Alexander S.; Reva, Anton A.; Shestov, Sergei V.; Ul'yanov, Artem S.; Vishnyakov, Eugene A.
2009-05-01
We report measurements of the reflection spectra of (i) concave (spherical and parabolic) Mo/Si, Mg/Si, and Al/Zr multilayer mirrors (MMs) intended for imaging solar spectroscopy in the framework of the TESIS/CORONAS-FOTON Satellite Project and of (ii) an aperiodic Mo/Si MM optimized for maximum uniform reflectivity in the 125-250 Å range intended for laboratory applications. The reflection spectra were measured in the configuration of a transmission grating spectrometer employing the radiation of a tungsten laser-driven plasma as the source. The function of detectors was fulfilled by backside-illuminated CCDs coated with Al or Zr/Si multilayer absorption filters. High-intensity second-order interference reflection peaks at wavelengths of about 160 Å were revealed in the reflection spectra of the 304-Å Mo/Si MMs. By contrast, the second-order reflection peak in the spectra of the new-generation narrow-band (~12 Å FWHM) 304-Å Mg/Si MMs is substantially depressed. Manifestations of the NEXAFS structure of the L2, 3 absorption edges of Al and Al2O3 were observed in the spectra recorded. The broadband Mo/Si MM was employed as the focusing element of spectrometers in experiments involving (i) the charge exchange of multiply charged ions with the donor atoms of a rare-gas jet; (ii) the spectroscopic characterization of a debris-free soft X-ray radiation source excited by Nd laser pulses in a Xe jet (iii) near-IR-to-soft-X-ray frequency conversion (double Doppler effect) occurring in the retroreflection from the relativistic electron plasma wake wave (flying mirror) driven by a multiterawatt laser in a pulsed helium jet.
Blood Pressure-Lowering Effect of Orally Ingested Nitrite Is Abolished by a Proton Pump Inhibitor.
Montenegro, Marcelo F; Sundqvist, Michaela L; Larsen, Filip J; Zhuge, Zhengbing; Carlström, Mattias; Weitzberg, Eddie; Lundberg, Jon O
2017-01-01
Inorganic nitrate and nitrite from dietary and endogenous sources are metabolized to NO and other bioactive nitrogen oxides that affect blood pressure. The mechanisms for nitrite bioactivation are unclear, but recent studies in rodents suggest that gastric acidity may influence the systemic effects of this anion. In a randomized, double-blind, placebo-controlled crossover study, we tested the effects of a proton pump inhibitor on the acute cardiovascular effects of nitrite. Fifteen healthy nonsmoking, normotensive subjects, aged 19 to 39 years, were pretreated with placebo or esomeprazole (3×40 mg) before ingesting sodium nitrite (0.3 mg kg -1 ), followed by blood pressure monitoring. Nitrite reduced systolic blood pressure by a maximum of 6±1.3 mm Hg when taken after placebo, whereas pretreatment with esomeprazole blunted this effect. Peak plasma nitrite, nitrate, and nitroso species levels after nitrite ingestion were similar in both interventions. In 8 healthy volunteers, we then infused increasing doses of sodium nitrite (1, 10, and 30 nmol kg -1 min -1 ) intravenously. Interestingly, although plasma nitrite peaked at similar levels as with orally ingested nitrite (≈1.8 µmol/L), no changes in blood pressure were observed. In rodents, esomeprazole did not affect the blood pressure response to the NO donor, DEA NONOate, or vascular relaxation to nitroprusside and acetylcholine, demonstrating an intact downstream NO-signaling pathway. We conclude that the acute blood pressure-lowering effect of nitrite requires an acidic gastric environment. Future studies will reveal if the cardiovascular complications associated with the use of proton pump inhibitors are linked to interference with the nitrate-nitrite-NO pathway. © 2016 American Heart Association, Inc.
NASA Astrophysics Data System (ADS)
Mancuso, S.; Giordano, S.; Raymond, J. C.
2016-06-01
In this work, we derive the O VI 1032 Å luminosity profiles of 58 flares, during their impulsive phase, based on off-limb measurements by the Ultraviolet Coronagraph Spectrometer (UVCS) aboard the SOlar and Heliospheric Observatory (SOHO). The O VI luminosities from the transition region plasma (here defined as the region with temperatures 5.0 ≤ log T (K) ≤ 6.0) were inferred from the analysis of the resonantly scattered radiation of the O VI coronal ions. The temperature of maximum ionization for O VI is log Tmax (K) = 5.47. By comparison with simultaneous soft X-ray measurements, we investigate the likely source (chromospheric evaporation, footpoint emission, or heated prominence ejecta) for the transition region emission observed during the impulsive phase. In our study, we find evidence of the main characteristics predicted by the evaporation scenario. Specifically, most O VI flares precede the X-ray peaks typically by several minutes with a mean of 3.2 ± 0.1 min, and clear correlations are found between the soft X-ray and transition region luminosities following power laws with indices ~ 0.7 ± 0.3. Overall, the results are consistent with transition region emission originating from chromospheric evaporation; the thermal X-ray emission peaks after the emission from the evaporation flow as the loops fill with hot plasma. Finally, we were able to infer flow speeds in the range ~20-100 km s-1 for one-third of the events, 14 of which showed speeds between 60 and 80 km s-1. These values are compatible with those found through direct spectroscopic observations at transition region temperatures by the EUV Imaging Spectrometer (EIS) on board Hinode.
Experiments and PIC simulations on liquid crystal plasma mirrors for pulse contrast enhancement
NASA Astrophysics Data System (ADS)
Cochran, G. E.; Poole, P. L.; Krygier, A.; Foster, P. S.; Scott, G. G.; Wilson, L. A.; Bailey, J.; Bourgeois, N.; Hernandez-Gomez, C.; Heery, R.; Purcell, J.; Neely, D.; Rajeev, P. P.; Freeman, R. R.; Schumacher, D. W.
2016-10-01
High pulse contrast is crucial for performing many experiments on high intensity lasers in order to minimize modification of the target surface by pre-pulse. This is often achieved through the use of solid dielectric plasma mirrors which can limit laser shot rates. Liquid crystal films, originally developed as variable thickness ion acceleration targets, have been demonstrated as effective plasma mirrors for pulse cleaning, reaching peak reflectivities over 70%. These films were used as plasma mirrors in an ion acceleration experiment on the Scarlet laser and the resultant increase in peak proton energy and change in acceleration direction will be discussed. Also presented here are novel 2D3V, LSP particle-in-cell simulations of dielectric plasma mirror operation. By including multiphoton ionization and dimensionality corrections, an excellent match to experiment is obtained over 4 decades in intensity. Analysis of pulse shortening and plasma critical surface behavior in these simulations will be discussed. Formation of thin films at 1.5 Hz will also be presented. Performed with support from the DARPA PULSE program through AMRDEC, from NNSA, and from OSC.
Jabs, Douglas A.; Forman, Michael; Enger, Cheryl; Jackson, J. Brooks
1999-01-01
Cytomegalovirus (CMV) DNA loads in paired leukocyte and plasma samples from 199 patient visits by 66 patients with CMV retinitis were determined. Leukocyte CMV load determinations had a greater range of values (mean, 24,587 copies/106 leukocytes; maximum, 539,000) than did plasma CMV load determinations (mean, 10,302 copies/ml; maximum, 386,000), and leukocyte viral loads were detectable in a greater proportion of patients at the time of diagnosis of CMV retinitis prior to initiation of anti-CMV therapy (82%) than were plasma viral loads (64%) (P = 0.0078). Agreement with CMV blood cultures was slightly better for plasma (κ = 0.68) than for leukocytes (κ = 0.53), due to a greater proportion of patients with detectable viral loads in leukocytes having negative blood cultures. PMID:10203500
Lijnen, P; Fagard, R; Staessen, J; Amery, A
1981-01-01
1 Chronic treatment with a constant dose of hydrochlorothiazide or tienilic acid increases plasma renin activity (PRA) acutely to reach a maximum within the first week. 2 During chronic diuretic therapy from 1 month to 1 year, PRA remained elevated at a rather constant level, though this was somewhat lower than the maximum level reached after 1 week. 3 A significant (P less than 0.01) correlation (r = 0.74) between changes in plasma angiotensin II and renin activity provoked by chronic treatment for 3 months with hydrochlorothiazide and tienilic acid was found. 4 The increase in plasma aldosterone during chronic treatment with hydrochlorothiazide and tienilic acid (1000 mg) is related (r = 0.68; P less than 0.01) to the rise in plasma angiotensin II. PMID:7028060
Non-invasive prenatal detection of achondroplasia using circulating fetal DNA in maternal plasma.
Lim, Ji Hyae; Kim, Mee Jin; Kim, Shin Young; Kim, Hye Ok; Song, Mee Jin; Kim, Min Hyoung; Park, So Yeon; Yang, Jae Hyug; Ryu, Hyun Mee
2011-02-01
To perform a reliable non-invasive detection of the fetal achondroplasia using maternal plasma. We developed a quantitative fluorescent-polymerase chain reaction (QF-PCR) method suitable for detection of the FGFR3 mutation (G1138A) causing achondroplasia. This method was applied in a non-invasive detection of the fetal achondroplasia using circulating fetal-DNA (cf-DNA) in maternal plasma. Maternal plasmas were obtained at 27 weeks of gestational age from women carrying an achondroplasia fetus or a normal fetus. Two percent or less achondroplasia DNA was reliably detected by QF-PCR. In a woman carrying a normal fetus, analysis of cf-DNA showed only one peak of the wild-type G allele. In a woman expected an achondroplasia fetus, analysis of cf-DNA showed the two peaks of wild-type G allele and mutant-type A allele and accurately detected the fetal achondroplasia. The non-invasive method using maternal plasma and QF-PCR may be useful for diagnosis of the fetal achondroplasia.
NASA Astrophysics Data System (ADS)
Cassibry, Jason; Dougherty, Jesse; Thompson, Seth; Hsu, Scott; Witherspoon, F. D.; University of AL in Huntsville Team; Los Alamos National Laboratory Team; HyperV Technologies Corp. Team
2014-10-01
Three-dimensional modeling of plasma liner formation and implosion is performed using the Smoothed Particle Hydrodynamics Code (SPHC) with radiation, thermal transport, and tabular equations of state (EOS), accounting for ionization, in support of a proposed 60-gun plasma liner formation experiment for plasma-jet driven magneto-inertial fusion (PJMIF). Previous SPHC modeling showed that ideal gas law scaling of peak stagnation pressure increased linearly with density and number of jets, quadratically with jet radius and velocity, and inversely with the initial jet length, while results with tabular EOS, thermal transport, and radiation have greater sensitivity to the initial jet distribution. A series of simulations are conducted to study the effects of initial jet conditions on peak ram pressure and liner non-uniformity during plasma liner implosion. The growth rate of large-amplitude density perturbations introduced by the discrete jets are computed and compared with predictions by the Bell-Plesset equation.
NASA Astrophysics Data System (ADS)
Christenson, M.; Stemmley, S.; Jung, S.; Mettler, J.; Sang, X.; Martin, D.; Kalathiparambil, K.; Ruzic, D. N.
2017-08-01
The ThermoElectric-driven Liquid-metal plasma-facing Structures (TELS) experiment at the University of Illinois is a gas-puff driven, theta-pinch plasma source that is used as a test stand for off-normal plasma events incident on materials in the edge and divertor regions of a tokamak. The ion temperatures and resulting energy distributions are crucial for understanding how well a TELS pulse can simulate an extreme event in a larger, magnetic confinement device. A retarding field energy analyzer (RFEA) has been constructed for use with such a transient plasma due to its inexpensive and robust nature. The innovation surrounding the use of a control analyzer in conjunction with an actively sampling analyzer is presented and the conditions of RFEA operation are discussed, with results presented demonstrating successful performance under extreme conditions. Such extreme conditions are defined by heat fluxes on the order of 0.8 GW m-2 and on time scales of nearly 200 μs. Measurements from the RFEA indicate two primary features for a typical TELS discharge, following closely with the pre-ionizing coaxial gun discharge characteristics. For the case using the pre-ionization pulse (PiP) and the theta pinch, the measured ion signal showed an ion temperature of 23.3 ± 6.6 eV for the first peak and 17.6 ± 1.9 eV for the second peak. For the case using only the PiP, the measured signal showed an ion temperature of 7.9 ± 1.1 eV for the first peak and 6.6 ± 0.8 eV for the second peak. These differences illustrate the effectiveness of the theta pinch for imparting energy on the ions. This information also highlights the importance of TELS as being one of the few linear pulsed plasma sources whereby moderately energetic ions will strike targets without the need for sample biasing.
Christenson, M; Stemmley, S; Jung, S; Mettler, J; Sang, X; Martin, D; Kalathiparambil, K; Ruzic, D N
2017-08-01
The ThermoElectric-driven Liquid-metal plasma-facing Structures (TELS) experiment at the University of Illinois is a gas-puff driven, theta-pinch plasma source that is used as a test stand for off-normal plasma events incident on materials in the edge and divertor regions of a tokamak. The ion temperatures and resulting energy distributions are crucial for understanding how well a TELS pulse can simulate an extreme event in a larger, magnetic confinement device. A retarding field energy analyzer (RFEA) has been constructed for use with such a transient plasma due to its inexpensive and robust nature. The innovation surrounding the use of a control analyzer in conjunction with an actively sampling analyzer is presented and the conditions of RFEA operation are discussed, with results presented demonstrating successful performance under extreme conditions. Such extreme conditions are defined by heat fluxes on the order of 0.8 GW m -2 and on time scales of nearly 200 μs. Measurements from the RFEA indicate two primary features for a typical TELS discharge, following closely with the pre-ionizing coaxial gun discharge characteristics. For the case using the pre-ionization pulse (PiP) and the theta pinch, the measured ion signal showed an ion temperature of 23.3 ± 6.6 eV for the first peak and 17.6 ± 1.9 eV for the second peak. For the case using only the PiP, the measured signal showed an ion temperature of 7.9 ± 1.1 eV for the first peak and 6.6 ± 0.8 eV for the second peak. These differences illustrate the effectiveness of the theta pinch for imparting energy on the ions. This information also highlights the importance of TELS as being one of the few linear pulsed plasma sources whereby moderately energetic ions will strike targets without the need for sample biasing.
NASA Technical Reports Server (NTRS)
Langowski, M.; vonSavigny, C.; Burrows, J. P.; Feng, W.; Plane, J. M. C.; Marsh, D. R.; Janches, Diego; Sinnhuber, M.; Aikin, A. C.
2014-01-01
Mg and Mg+ concentration fields in the upper mesosphere/lower thermosphere (UMLT) region are retrieved from SCIAMACHY/Envisat limb measurements of Mg and Mg+ dayglow emissions using a 2-D tomographic retrieval approach. The time series of monthly means of Mg and Mg+ for number density as well as vertical column density in different latitudinal regions are shown. Data from the limb mesosphere-thermosphere mode of SCIAMACHY/Envisat are used, which covers the 50 km to 150 km altitude region with a vertical sampling of 3.3 km and a highest latitude of 82 deg. The high latitudes are not covered in the winter months, because there is no dayglow emission during polar night. The measurements were performed every 14 days from mid-2008 until April 2012. Mg profiles show a peak at around 90 km altitude with a density between 750 cm(exp-3) and 2000 cm(exp-3). Mg does not show strong seasonal variation at mid-latitudes. The Mg+ peak occurs 5-15 km above the neutral Mg peak at 95-105 km. Furthermore, the ions show a significant seasonal cycle with a summer maximum in both hemispheres at mid- and high-latitudes. The strongest seasonal variations of the ions are observed at mid-latitudes between 20-40 deg and densities at the peak altitude range from 500 cm(exp-3) to 6000 cm(exp-3). The peak altitude of the ions shows a latitudinal dependence with a maximum at mid-latitudes that is up to 10 km higher than the peak altitude at the equator. The SCIAMACHY measurements are compared to other measurements and WACCM model results. In contrast to the SCIAMACHY results, the WACCM results show a strong seasonal variability for Mg with a winter maximum, which is not observable by SCIAMACHY, and globally higher peak densities. Although the peak densities do not agree the vertical column densities agree, since SCIAMACHY results show a wider vertical profile. The agreement of SCIAMACHY and WACCM results is much better for Mg+, showing the same seasonality and similar peak densities. However, there are the following minor differences: there is no latitudinal dependence of the peak altitude for WACCM and the density maximum, passing the equatorial region during equinox conditions, is not reduced as for SCIAMACHY.
Impact of temperature-velocity distribution on fusion neutron peak shape
Munro, D. H.; Field, J. E.; Hatarik, R.; ...
2017-02-21
Doppler broadening of the 14 MeV DT and 2.45 MeV DD fusion neutron lines has long been our best measure of temperature in a burning plasma. At the National Ignition Facility (NIF), yields are high enough and our neutron spectrometers accurate enough that we see finer details of the peak shape. For example, we can measure the shift of the peak due to the bulk motion of the plasma, and we see indications of non-thermal broadening, skew, and kurtosis of the peak caused by the variations of temperature and fluid velocity during burn. We can also distinguish spectral differences amongmore » several lines of sight. Finally, this paper will review the theory of fusion neutron line shape, show examples of non-Gaussian line shapes and directional variations in NIF data, and describe detailed spectral shapes we see in radiation-hydrodynamics simulations of implosions.« less
Impact of temperature-velocity distribution on fusion neutron peak shape
NASA Astrophysics Data System (ADS)
Munro, D. H.; Field, J. E.; Hatarik, R.; Peterson, J. L.; Hartouni, E. P.; Spears, B. K.; Kilkenny, J. D.
2017-05-01
Doppler broadening of the 14 MeV DT and 2.45 MeV DD fusion neutron lines has long been our best measure of temperature in a burning plasma. At the National Ignition Facility (NIF), yields are high enough and our neutron spectrometers accurate enough that we see finer details of the peak shape. For example, we can measure the shift of the peak due to the bulk motion of the plasma, and we see indications of non-thermal broadening, skew, and kurtosis of the peak caused by the variations of temperature and fluid velocity during burn. We can also distinguish spectral differences among several lines of sight. This paper will review the theory of fusion neutron line shape, show examples of non-Gaussian line shapes and directional variations in NIF data, and describe detailed spectral shapes we see in radiation-hydrodynamics simulations of implosions.
Ion velocity distributions in dipolarization events: Distributions in the central plasma sheet
NASA Astrophysics Data System (ADS)
Birn, J.; Runov, A.; Zhou, X.-Z.
2017-08-01
Using combined MHD/test particle simulations, we further explore characteristic ion velocity distributions in the central plasma sheet (CPS) in relation to dipolarization events. Distributions in the CPS within the dipolarized flux bundle (DFB) that follows the passage of a dipolarization front typically show two opposing low subthermal-energy beams with a ring-like component perpendicular to the magnetic field at about twice the thermal energy. The dominance of the perpendicular anisotropy and a field-aligned peak at lower energy agree qualitatively with ion distribution functions derived from "Time History of Events and Macroscale Interactions during Substorms" observations. At locations somewhat off the equatorial plane the field-aligned peaks are shifted by a field-aligned component of the bulk flow, such that one peak becomes centered near zero net velocity, which makes it less likely to be observed. The origins of the field-aligned peaks are low-energy lobe (or near plasma sheet boundary layer) regions, while the ring distribution originates mostly from thermal plasma sheet particles on extended field lines. The acceleration mechanisms are also quite different: the beam ions are accelerated first by the E × B drift motion of the DFB and then by a slingshot effect of the earthward convecting DFB (akin to first-order Fermi, type B, acceleration), which causes an increase in field-aligned speed. In contrast, the ring particles are accelerated by successive, betatron-like acceleration after entering the high electric field region of an earthward propagating DFB.
NASA Astrophysics Data System (ADS)
Zhang, Bo; Fang, Zhi; Liu, Feng; Zhou, Renwu; Zhou, Ruoyu
2018-06-01
Using an atmospheric pressure plasma jet array is an effective way for expanding the treatment area of a single jet, and generating arrays with well downstream uniformity is of great interest for its applications. In this paper, a plasma jet array in helium is generated in a linear-field jet array with a ring-ring electrode structure excited by alternating current. The characteristics and downstream uniformity of the array and their dependence on the applied voltage and gas flow rate are investigated through optical, electrical, and Schlieren diagnostics. The results are compared with those of our reported work of a cross-field jet array with a needle-ring electrode structure. The results show that the linear-field jet array can generate relatively large-scale plasma with better uniformity and longer plumes than the cross-field case. The divergences observed in gas channels and the plasma plume trajectories are much less than those of the cross-field one. The deflection angle of lateral plumes is less than 6°, which is independent of the gas flow rate and applied voltage. The maximum downstream plumes of 23 mm can be obtained at 7 kV peak applied voltage and 4 l/min gas flow rate. The better uniformity of linear-field jet arrays is due to the effective suppression of hydrodynamic and electrical interactions among the jets in the arrays with a more uniform electric field distribution. The hydrodynamic interaction induced by the gas heating in the linear-field jet array is less than that of the cross-field one. The more uniform electric field distribution in the linear-field jet arrays can reduce the divergence of the propagation trajectories of the plasma plumes. It will generate less residual charge between the adjacent discharges and thus can reduce the accumulation effect of Coulomb force between the plasma plumes. The reported results can help design controllable and scalable plasma jet arrays with well uniformity for material surface and biomedical treatments.
Ionospheres of outer planet satellites: The legacy of Galileo and the promise of Cassini
NASA Astrophysics Data System (ADS)
Kliore, A. J.; Nagy, A. F.
The Galileo spacecraft was placed into orbit about Jupiter in 1995 and until the end of 2003 it has provided multiple opportunities for the study of the plasma environments of the icy Galilean satellites Europa, Ganymede, and Callisto by means of radio occultation of its S-band (13.5 cm. wavelength) signal. There have been four occultations each by Europa, Ganymede, and Callisto that have provided useful data, in addition to five occultations by the volcanic satellite Io.. Analysis of these data revealed small excursions in the received frequency (of the order of 0.01 Hz, or about 4 parts in 1012), which indicated the presence of tenuous plasma above the surfaces of these bodies. When observed, the maximum electron densities range from about 5 to about 20 x 103 cm-3. The vertical structure of these plasma layers range from classical ionospheric profiles observed at Callisto on two occasions, to multi-peaked structures observed at Europa. On several occasions no discernible plasma was observed. These observations could be explained by a process in which a tenuous neutral atmosphere (about 1010 cm-3), consisting dissociation products of H2O, is created on the trailing hemisphere of the satellite by sputtering from the icy surface by energetic particles of the Jovian magnetosphere. If the trailing hemisphere is at that time also illuminated by the Sun, plasma is produced by photoionization, and is observed by radio occultation. The configuration of this plasma is, however, determined by its interaction with the corotating Jovian magnetospheric plasma, which under certain geometries would lead to the observation of multipeaked structures. The Cassini orbiter, which will be placed into orbit about Saturn in 2004 , will provide at least four occultations of Titan. In contrast to Galileo, Cassini has three downlink frequencies - in addition to s-band, it also has x-band (˜ 5.5 cm), and Ka-band (˜ 1 cm) downlinks, which will provide excellent data on Titan's ionosphere and plasma environment during the standard tour of the Saturnian system, and possibly of some of the icy satellites during the extended mission..
About an Extreme Achievable Current in Plasma Focus Installation of Mather Type
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nikulin, V. Ya.; Polukhin, S. N.; Vikhrev, V. V.
A computer simulation and analytical analysis of the discharge process in Plasma Focus has shown that there is an upper limit to the current which can be achieved in Plasma Focus installation of Mather type by only increasing the capacity of the condenser bank. The maximum current achieved for various plasma focus installations of 1 MJ level is discussed. For example, for the PF-1000 (IFPiLM) and 1 MJ Frascati PF, the maximum current is near 2 MA. Thus, the commonly used method of increasing the energy of the PF installation by increasing of the capacity has no merit. Alternative optionsmore » in order to increase the current are discussed.« less
Asymmetric SOL Current in Vertically Displaced Plasma
NASA Astrophysics Data System (ADS)
Cabrera, J. D.; Navratil, G. A.; Hanson, J. M.
2017-10-01
Experiments at the DIII-D tokamak demonstrate a non-monotonic relationship between measured scrape-off layer (SOL) currents and vertical displacement event (VDE) rates with SOL currents becoming largely n=1 dominant as plasma is displaced by the plasma control system (PCS) at faster rates. The DIII-D PCS is used to displace the magnetic axis 10x slower than the intrinsic growth time of similar instabilities in lower single-null plasmas. Low order (n <=2) mode decomposition is done on toroidally spaced current monitors to attain measures of asymmetry in SOL current. Normalized to peak n=0 response, a 2-4x increase is seen in peak n=1 response in plasmas displaced by the PCS versus previous VDE instabilities observed when vertical control is disabled. Previous inquiry shows VDE asymmetry characterized by SOL current fraction and geometric parameters of tokamak plasmas. We note that, of plasmas displaced by the PCS, short displacement time scales near the limit of the PCS temporal control appear to result in larger n=1/n=2 asymmetries. Work supported under USDOE Cooperative Agreement DE-FC02-04ER54698 and DE-FG02-04ER54761.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Digenis, G.A.; Sandefer, E.P.; Parr, A.F.
The behavior of single 250-mg doses of a multiparticulate form of erythromycin base (ERYC(R)), each including five pellets radiolabeled with neutron-activated samarium-153, was observed by gamma scintigraphy in seven male subjects under fasting and nonfasting conditions. The residence time and locus of radiolabeled pellets within regions of the gastrointestinal tract were determined and were correlated with plasma concentrations of erythromycin at coincident time points. Administration of food 30 minutes postdosing reduced fasting plasma erythromycin Cmax and area under the plasma erythromycin versus time curve (AUC) values by 43% and 54%, respectively. Mean peak plasma concentration of erythromycin (Cmax) in themore » fasting state was 1.64 micrograms/mL versus 0.94 micrograms/mL in the nonfasting state. Total oral bioavailability, as determined by mean AUC (0-infinity) of the plasma erythromycin concentration versus time curve, was 7.6 hr/micrograms/mL in the fasted state, versus 3.5 hr/micrograms/mL in the nonfasting state. Mean time to peak plasma erythromycin concentration (tmax) in the fasting state was 3.3 hours, versus 2.3 hours in the nonfasting state. Plasma concentrations of erythromycin in both fasting and nonfasting states were within acceptable therapeutic ranges.« less
Liu, Zhi-Jie; Wang, Wen-Chun; Yang, De-Zheng; Wang, Sen; Zhang, Shuai; Tang, Kai; Jiang, Peng-Chao
2014-01-01
A large-area diffuse air discharge plasma excited by bipolar nanosecond pulse is generated under a double hexagon needle-array electrode at atmospheric pressure. The images of the diffuse discharge, electric characteristics, and the optical emission spectra emitted from the diffuse air discharge plasma are obtained. Based on the waveforms of pulse voltage and current, the power consumption, and the power density of the diffuse air discharge plasma are investigated under different pulse peak voltages. The electron density and the electron temperature of the diffuse plasma are estimated to be approximately 1.42×10(11) cm(-3) and 4.4 eV, respectively. The optical emission spectra are arranged to determine the rotational and vibrational temperatures by comparing experimental with simulated spectra. Meanwhile, the rotational and vibrational temperatures of the diffuse discharge plasma are also discussed under different pulse peak voltages and pulse repetition rates, respectively. In addition, the diffuse air discharge plasma can form an area of about 70×50 mm(2) on the surface of dielectric layer and can be scaled up to the required size. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Washeleski, Robert L.; Meyer, Edmond J. IV; King, Lyon B.
2013-10-15
Laser Thomson scattering (LTS) is an established plasma diagnostic technique that has seen recent application to low density plasmas. It is difficult to perform LTS measurements when the scattered signal is weak as a result of low electron number density, poor optical access to the plasma, or both. Photon counting methods are often implemented in order to perform measurements in these low signal conditions. However, photon counting measurements performed with photo-multiplier tubes are time consuming and multi-photon arrivals are incorrectly recorded. In order to overcome these shortcomings a new data analysis method based on maximum likelihood estimation was developed. Themore » key feature of this new data processing method is the inclusion of non-arrival events in determining the scattered Thomson signal. Maximum likelihood estimation and its application to Thomson scattering at low signal levels is presented and application of the new processing method to LTS measurements performed in the plume of a 2-kW Hall-effect thruster is discussed.« less
Washeleski, Robert L; Meyer, Edmond J; King, Lyon B
2013-10-01
Laser Thomson scattering (LTS) is an established plasma diagnostic technique that has seen recent application to low density plasmas. It is difficult to perform LTS measurements when the scattered signal is weak as a result of low electron number density, poor optical access to the plasma, or both. Photon counting methods are often implemented in order to perform measurements in these low signal conditions. However, photon counting measurements performed with photo-multiplier tubes are time consuming and multi-photon arrivals are incorrectly recorded. In order to overcome these shortcomings a new data analysis method based on maximum likelihood estimation was developed. The key feature of this new data processing method is the inclusion of non-arrival events in determining the scattered Thomson signal. Maximum likelihood estimation and its application to Thomson scattering at low signal levels is presented and application of the new processing method to LTS measurements performed in the plume of a 2-kW Hall-effect thruster is discussed.
Ionospheric irregularities and acoustic/gravity wave activity above low-latitude thunderstorms
Lay, Erin H.
2017-12-18
Ionospheric irregularities due to plasma bubbles, scintillation, and acoustic/gravity waves are studied in the low-latitude ionosphere in relation to thunderstorm activity. Ionospheric total electron content (TEC) measurements from the Low Latitude Ionospheric Sensor Network (LISN) and lightning measurements from the World-Wide Lightning Location Network (WWLLN) are compared during two summer months and two winter months in 2013. Large amplitude fluctuations in TEC are found to have a strongly-peaked diurnal pattern in the late evening and nighttime summer ionosphere. The maximum magnitude and coverage area of these fluctuations increases as thunderstorm area increases. Summertime mid-amplitude fluctuations do not exhibit the samemore » diurnal variation, but do increase in magnitude and coverage area as thunderstorm area increases. Wintertime ionospheric fluctuations do not appear to be related to thunderstorm activity. Lastly, these findings show that thunderstorms have an observable effect on magnitude and coverage area of ionospheric fluctuations.« less
Ionospheric irregularities and acoustic/gravity wave activity above low-latitude thunderstorms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lay, Erin H.
Ionospheric irregularities due to plasma bubbles, scintillation, and acoustic/gravity waves are studied in the low-latitude ionosphere in relation to thunderstorm activity. Ionospheric total electron content (TEC) measurements from the Low Latitude Ionospheric Sensor Network (LISN) and lightning measurements from the World-Wide Lightning Location Network (WWLLN) are compared during two summer months and two winter months in 2013. Large amplitude fluctuations in TEC are found to have a strongly-peaked diurnal pattern in the late evening and nighttime summer ionosphere. The maximum magnitude and coverage area of these fluctuations increases as thunderstorm area increases. Summertime mid-amplitude fluctuations do not exhibit the samemore » diurnal variation, but do increase in magnitude and coverage area as thunderstorm area increases. Wintertime ionospheric fluctuations do not appear to be related to thunderstorm activity. Lastly, these findings show that thunderstorms have an observable effect on magnitude and coverage area of ionospheric fluctuations.« less
Influence of insulating coating on aluminum wire explosions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Yang; Wu, Jian, E-mail: jxjawj@gmail.com; State Key Laboratory of Intense Pulse Radiation of Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an 710024
2014-10-15
Single wire explosions are widely used in understanding the early stages of z-pinch experiments. This paper presents a serial of experiments conducted on the pulse power generator with ∼1 kA peak current and ∼10 ns rising time in Xi'an Jiao Tong University. Polyimide coated aluminum wires and uncoated ones were tested under three different voltages to analyze the effect of insulating coating. Experimental results showed that insulating coating can increase the energy deposition 10%∼30% in aluminum wires by delaying the voltage collapse and raising the maximum load resistance. The substantial energy deposition resulted in about 20% faster expansion rates for coated wires.more » Experimental evidence that plasma channel shunts the current from the wire core was observed by streak camera and schlieren graphs. This paper also briefly discussed the influence of nonuniform coating on the morphology of wire expansion.« less
NASA Astrophysics Data System (ADS)
Coscia, U.; Ambrosone, G.; Basa, D. K.
2008-03-01
The nanocrystalline silicon embedded in amorphous silicon carbide matrix was prepared by varying rf power in high vacuum plasma enhanced chemical vapor deposition system using silane methane gas mixture highly diluted in hydrogen. In this paper, we have studied the evolution of the structural, optical, and electrical properties of this material as a function of rf power. We have observed visible photoluminescence at room temperature and also have discussed the role played by the Si nanocrystallites and the amorphous silicon carbide matrix. The decrease of the nanocrystalline size, responsible for quantum confinement effect, facilitated by the amorphous silicon carbide matrix, is shown to be the primary cause for the increase in the PL intensity, blueshift of the PL peak position, decrease of the PL width (full width at half maximum) as well as the increase of the optical band gap and the decrease of the dark conductivity.
Ionospheric Irregularities and Acoustic/Gravity Wave Activity Above Low-Latitude Thunderstorms
NASA Astrophysics Data System (ADS)
Lay, Erin H.
2018-01-01
Ionospheric irregularities due to plasma bubbles, scintillation, and acoustic/gravity waves are studied in the low-latitude ionosphere in relation to thunderstorm activity. Ionospheric total electron content (TEC) measurements from the Low Latitude Ionospheric Sensor Network and lightning measurements from the World-Wide Lightning Location Network are compared during two summer months and two winter months in 2013. Large amplitude fluctuations in TEC are found to have a strongly peaked diurnal pattern in the late evening and nighttime summer ionosphere. The maximum magnitude and coverage area of these fluctuations increases as thunderstorm area increases. Summertime midamplitude fluctuations do not exhibit the same diurnal variation but do increase in magnitude and coverage area as thunderstorm area increases. Wintertime ionospheric fluctuations do not appear to be related to thunderstorm activity. These findings show that thunderstorms have an observable effect on magnitude and coverage area of ionospheric fluctuations.
Final Report: Levitated Dipole Experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kesner, Jay; Mauel, Michael
2013-03-10
Since the very first experiments with the LDX, research progress was rapid and significant. Initial experiments were conducted with the high-field superconducting coil suspended by three thin rods. These experiments produced long-pulse, quasi-steady-state microwave discharges, lasting more than 10 s, having peak beta values of 20% [Garnier et al., Physics of Plasmas, 13 (2006) 056111]. High- beta, near steady-state discharges have been maintained in LDX for more than 20 seconds, and this capability made LDX the longest pulse fusion confinement experiment operating in the U.S. fusion program. A significant measure of progress in the LDX research program was the routinemore » investigation of plasma confinement with a magnetically-levitated dipole and the resulting observations of confinement improvement. In both supported and levitated configurations, detailed measurements were made of discharge evolution, plasma dynamics and instability, and the roles of gas fueling, microwave power deposition profiles, and plasma boundary shape. High-temperature plasma was created by multi frequency electron cyclotron resonance heating at 2.45 GHz, 6.4 GHz, 10.5 GHz and 28 GHz allowing control of heating profiles. Depending upon neutral fueling rates, the LDX discharges contain a fraction of energetic electrons, with mean energies above 50 keV. Depending on whether or not the superconducting dipole was levitated or supported, the peak thermal electron temperature was estimated to exceed 500 eV and peak densities to approach 1e18 m -3. We have found that levitation causes a strong inwards density pinch [Boxer et al., Nature Physics, 6 (2010) 207] and we have observed the central plasma density increase dramatically indicating a significant improvement in the confinement of a thermal plasma species.« less
Sooriyaarachchi, Melani; Gailer, Jürgen
2010-08-28
The iron chelation therapy drugs desferrioxamine B (DFO) and deferiprone (DFP) are used to treat iron overload patients, but not much is known about their adverse effects on other essential metals in vivo. After the addition of a clinically relevant dose of DFP or an equimolar dose of DFO to human plasma in vitro, the mixtures were analyzed by size exclusion chromatography (SEC) coupled to an inductively coupled plasma atomic emission spectrometer (ICP-AES). Simultaneous detection of the emission lines of copper, iron and zinc allowed the visualization of changes that these drugs exerted at the metalloprotein level. After the addition of DFP, a <10 kDa novel Fe-peak was detected and identified as (DFP)(3)Fe, whereas DFO resulted in the elution of a much smaller amount of Fe in this elution range. In fact, DFP was approximately 8-times more efficient than DFO regarding the removal of Fe from plasma proteins. The addition of both iron chelators also resulted in the elution of a <10 kDa novel Zn-peak. DFP abstracted twice as much Zn from plasma proteins compared to DFO. The identification of one of these peaks as (DFP)(2)Zn establishes a feasible biomolecular basis for the etiology of Zn-deficiency in patients that undergo long-term treatment with these drugs. Our results demonstrate that the analysis of plasma by SEC-ICP-AES can simultaneously provide insight into the efficacy of chelation therapy drugs and their adverse health effects at the metalloprotein level. Thus, SEC-ICP-AES emerges as a useful analytical tool to visualize health-relevant bioinorganic chemistry-related reactions of medicinal drugs in blood plasma in vitro.
Karlson, Björn W; Dellborg, Mikael; Gullestad, Lars; Aberg, Jan; Sugg, Jennifer; Herlitz, Johan
2014-01-01
Previous metoprolol studies in myocardial infarction patients were performed with immediate-release (IR) metoprolol. This study aims to evaluate if extended-release metoprolol CR/XL once daily gives a similar β-blockade over 24 h compared to multiple dosing of metoprolol IR. After 2 days of routine metoprolol treatment, 27 patients with suspected acute myocardial infarction were randomized to open-label treatment with metoprolol IR (50 mg four times daily or 100 mg twice daily) or metoprolol CR/XL 200 mg once daily for 3 days. Metoprolol CR/XL 200 mg once daily gave more pronounced suppression of peak heart rate, with lower peak and less variation in peak to trough plasma levels. There were no differences in AUC between the CR/XL and IR formulations, although the trough plasma metoprolol levels were comparable for metoprolol CR/XL 200 mg once daily and metoprolol IR 50 mg four times daily, but lower for metoprolol IR 100 mg twice daily. Both treatments were well tolerated. Metoprolol CR/XL 200 mg once daily showed lower peak and less variation in peak to trough plasma levels compared to multiple dosing of metoprolol IR with the same AUC. This was accompanied by a more uniform β-blockade over time, which was reflected by heart rate, and a more pronounced suppression of peak heart rate with similar tolerability. This suggests metoprolol CR/XL may be used as an alternative to metoprolol IR in patients with myocardial infarction. © 2013 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Eidietis, N. W.
2016-10-01
Measurements of poloidal asymmetry in the radiated power during thermal quench (TQ) mitigation by massive gas injection (MGI) on DIII-D show poloidal peaking in the radiated heat flux at the wall generally consistent with 3D resistive MHD modeling, that indicates a large n=1 tearing mode causes these asymmetries. Radiation asymmetries are a concern to ITER because they can cause localized melting of the first wall even if globally the mitigation successfully radiates 100% of the plasma thermal energy. Toroidal radiation asymmetries have been well-studied, but until now the equally important poloidal asymmetries were not well constrained. Radiation emissivity profiles are reconstructed by tomographic inversion of AXUV photodiode arrays, from which the peaking measurements are derived. The poloidal peaking measurements are compared to NIMROD 3D resistive MHD simulations. Qualitatively, the measured and modeled peaking evolve similarly. In both cases, peaking during the TQ changes little with toroidal phase, consistent with predictions of n=1 MHD during the TQ producing the asymmetry. Quantitatively, the measured TQ peaking amplitudes are comparable to but consistently higher than the modeled values. This is a result of the measured radiation exhibiting high emissivity lobes at larger minor radius (and outside the separatrix) than the modeled cases, which may indicate incomplete treatment of the plasma-neutral interaction at the plasma edge in the model. This work, combined with previous measurement and modeling and toroidal radiation asymmetries, provides a basis for constraining localized mitigation radiation heat flux in ITER. Work supported by US DOE under DE-FC02-04ER54698.
NASA Astrophysics Data System (ADS)
Kim, Joon Hyub; Lee, Jun-Yong; Jin, Joon-Hyung; Park, Eun Jin; Min, Nam Ki
2013-01-01
The single-walled carbon nanotube (SWCNT)-based thin film was spray-coated on the Pt support and functionalized using O2 plasma. The effects of plasma treatment on the biointerfacial properties of the SWCNT films were analyzed by cyclic voltammogram (CV), electrochemical impedance spectroscopy (EIS), and differential pulse voltammetry (DPV). The plasma-functionalized (pf) SWCNT electrodes modified with Legionella pneumophila-specific probe DNA strands showed a much higher peak current and a smaller peak separation in differential pulse voltammetry and a lower charge transfer resistance, compared to the untreated samples. These results suggest that the pf-SWCNT films have a better electrocatalytic character and an electron transfer capability faster than the untreated SWCNTs, due to the fact that the oxygen-containing functional groups promote direct electron transfer in the biointerfacial region of the electrocatalytic activity of redox-active biomolecules.
Power and Particle Balance Calculations with Impurities in NSTX
NASA Astrophysics Data System (ADS)
Holland, C. G.; Maingi, R.; Owen, L. W.; Kaye, S. M.
1998-11-01
We reported the development C. Holland, et. al., Bull. Am. Phys. Soc. 42 (1997) 1927. and application R. Maingi et al., Proc. 3rd International Workshop on Spherical Tori, Sept. 3-5, 1997, St. Petersburg, Russia. of a Graphical User Interface to assess the important terms for edge and divertor plasma calculations for NSTX with the b2.5 edge plasma transport code B. Braams, Contrib. Plasma Phys. 36 (1996) 276.. The goals of those calculations were to estimate the worst case peak heat flux for plasma-facing component design, and the radiation requirements to reduce the peak heat flux. In this study we present the first simulations with intrinsic carbon impurity radiation. We find in general that the intrinsic carbon radiation should be sufficient to provide a wide operation window for the NSTX device. Details of the relative importance of heat flux transport mechanisms as determined with the GUI will be presented.
Transport Studies in Alcator C-Mod ITB Plasmas
NASA Astrophysics Data System (ADS)
Fiore, C. L.; Bonoli, P. T.; Ernst, D.; Greenwald, M. J.; Ince-Cushman, A.; Lin, L.; Marmar, E. S.; Porkolab, M.; Rice, J. E.; Wukitch, S.; Rowan, W.; Bespamyatnov, I.; Phillips, P.
2008-11-01
Internal transport barriers occur in C-Mod plasmas that have off-axis ICRF heating and also in Ohmic H-mode plasmas. These ITBs are marked by highly peaked density and pressure profiles, as they rely on a reduction of particle and thermal flux in the barrier region which allows the neoclassical pinch to peak the central density without reducing the central temperature. Enhancement of several core diagnostics has resulted in increased understanding of C-Mod ITBs. Ion temperature profile measurements have been obtained using an innovative design for x-ray crystal spectrometry and clearly show a barrier forming in the ion temperature profile. The phase contrast imaging (PCI) provides limited localization of the ITB related fluctuations that increase in strength as the central density increases. Simulation of triggering conditions, integrated simulations with fluctuation measurements, parametric studies, and transport implications of fully ionized boron impurity profiles in the plasma are under study. A summary of these results will be presented.
B2.5-Eirene modeling of radial transport in the MAGPIE linear plasma device
NASA Astrophysics Data System (ADS)
Owen, L. W.; Caneses, J. F.; Canik, J.; Lore, J. D.; Corr, C.; Blackwell, B.; Bonnin, X.; Rapp, J.
2017-05-01
Radial transport in helicon heated hydrogen plasmas in the MAGnetized Plasma Interaction Experiment (MAGPIE) is studied with the B2.5-Eirene (SOLPS5.0) code. Radial distributions of plasma density, temperature and ambipolar potential are computed for several magnetic field configurations and compared to double Langmuir probe measurements. Evidence for an unmagnetized ion population is seen in the requirement for a convective pinch term in the continuity equation in order to fit the centrally peaked density profile data. The measured slightly hollow electron temperature profiles are reproduced with combinations of on-axis and edge heating which can be interpreted as helicon and Trivelpiece-Gould wave absorption, respectively. Pressure gradient driven radial charged particle diffusion is chosen to describe the diffusive particle flux since the hollowness of the temperature profiles assists the establishment of on-axis density peaking.
Electron plasma oscillations in the Venus foreshock
NASA Technical Reports Server (NTRS)
Crawford, G. K.; Strangeway, R. J.; Russell, C. T.
1990-01-01
Plasma waves are observed in the solar wind upstream of the Venus bow shock by the Pioneer Venus Orbiter. These wave signatures occur during periods when the interplanetary magnetic field through the spacecraft position intersects the bow shock, thereby placing the spacecraft in the foreshock region. The electron foreshock boundary is clearly evident in the data as a sharp onset in wave activity and a peak in intensity. Wave intensity is seen to drop rapidly with increasing penetration into the foreshock. The peak wave electric field strength at the electron foreshock boundary is found to be similar to terrestrial observations. A normalized wave spectrum was constructed using measurements of the electron plasma frequency and the spectrum was found to be centered about this value. These results, along with polarization studies showing the wave electric field to be field aligned, are consistent with the interpretation of the waves as electron plasma oscillations.
Mechanism of Growth Enhancement of Plants Induced by Active Species in Plasmas
NASA Astrophysics Data System (ADS)
Watanabe, Satoshi; Ono, Reoto; Hayashi, Nobuya
2015-09-01
Plant growth enhances when seeds are irradiated by plasma. However the mechanism of the growth enhancement by plasma has not been clarified. In this study, growth enhancement of plants using various active species and variation of plant cells are investigated. RF plasma is generated under conditions where pressure is 60 Pa and input electrical power is 60 W. Irradiation period varies from 0 (control) to 75 min. Air plasma shows maximum growth of plants with irradiation period of 60 min on the other hand, oxygen plasma shows the maximum growth with irradiation period of 15 min. From change of gaseous species and pressure dependence, growth enhancing factor is expected to be active oxygen species produced in plasma. According to gene expression analysis of Arabidopsis, there are two speculated mechanism of plant growth enhancement. The first is acceleration of cell cycle by gene expressions of photosynthesis and glycolytic pathway, and the second is increase of cell size via plant hormone production.
Negative specific heat of a magnetically self-confined plasma torus
Kiessling, Michael K.-H.; Neukirch, Thomas
2003-01-01
It is shown that the thermodynamic maximum-entropy principle predicts negative specific heat for a stationary, magnetically self-confined current-carrying plasma torus. Implications for the magnetic self-confinement of fusion plasma are considered. PMID:12576553
Development of magnitude scaling relationship for earthquake early warning system in South Korea
NASA Astrophysics Data System (ADS)
Sheen, D.
2011-12-01
Seismicity in South Korea is low and magnitudes of recent earthquakes are mostly less than 4.0. However, historical earthquakes of South Korea reveal that many damaging earthquakes had occurred in the Korean Peninsula. To mitigate potential seismic hazard in the Korean Peninsula, earthquake early warning (EEW) system is being installed and will be operated in South Korea in the near future. In order to deliver early warnings successfully, it is very important to develop stable magnitude scaling relationships. In this study, two empirical magnitude relationships are developed from 350 events ranging in magnitude from 2.0 to 5.0 recorded by the KMA and the KIGAM. 1606 vertical component seismograms whose epicentral distances are within 100 km are chosen. The peak amplitude and the maximum predominant period of the initial P wave are used for finding magnitude relationships. The peak displacement of seismogram recorded at a broadband seismometer shows less scatter than the peak velocity of that. The scatters of the peak displacement and the peak velocity of accelerogram are similar to each other. The peak displacement of seismogram differs from that of accelerogram, which means that two different magnitude relationships for each type of data should be developed. The maximum predominant period of the initial P wave is estimated after using two low-pass filters, 3 Hz and 10 Hz, and 10 Hz low-pass filter yields better estimate than 3 Hz. It is found that most of the peak amplitude and the maximum predominant period are estimated within 1 sec after triggering.
Fontaine, Richard A.; Hill, Barry R.
2002-01-01
A combination of several meteorologic and topographic factors produced extreme rainfall over the eastern part of the island of Hawaii on November 1-2, 2000. Storm rainfall was concentrated in two distinct areas, the Waiakea and Kapapala areas, where maximum rainfall totals of 32.47 and 38.97 inches were recorded. Resultant flooding caused damages in excess of 70 million dollars, among the highest totals associated with flooding in the State's history. Storm rainfall had recurrence intervals that ranged from 10 years or less for maximum 1-hour totals to 100 years or more for maximum 24-hour totals As part of this study, peak flow and/or erosion data were collected at 41 sites. Analyses of these data indicated that peak discharges of record occurred at 6 of 12 sites where historic data were available. Peak flows with estimated recurrence intervals from 50 to over 100 years were recorded at 4 of 11 sites. Peak flows were poorly correlated with total storm rainfall. Critical rainfall durations associated with peak flows ranged from 1 to 12 hours and were about 3 hours at most sites. Rainfall-runoff computations and field observations indicated that infiltration-excess overland flow alone was not sufficient to have caused the observed flood peaks and therefore saturation-excess overland flow and subsurface flow probably contributed to peak flows at most sites Most hillslope erosion associated with the storm took place along or near the Kaoiki Pali in the Kapapala area. Hillslope erosion was predominately caused by overland flow.
Topside Ionospheric Response to Solar EUV Variability
NASA Astrophysics Data System (ADS)
Anderson, P. C.; Hawkins, J.
2015-12-01
We present an analysis of 23 years of thermal plasma measurements in the topside ionosphere from several DMSP spacecraft at ~800 km. The solar cycle variations of the daily averaged densities, temperatures, and H+/O+ ratios show a strong relationship to the solar EUV as described by the E10.7 solar EUV proxy with cross-correlation coefficients (CCCs) with the density greater than 0.85. The H+/O+ varies dramatically from solar maximum when it is O+ dominated to solar minimum when it is H+ dominated. These ionospheric parameters also vary strongly with season, particularly at latitudes well away from the equator where the solar zenith angle (SZA) varies greatly with season. There are strong 27-day solar rotation periodicities in the density, associated with the periodicities in the solar EUV as measured by the TIMED SEE and SDO EVE instruments, with CCCs at times greater than 0.9 at selected wavelengths. Empirical Orthogonal Function (EOF) analysis captures over 95% of the variation in the density over the 23 years in the first two principle components. The first principle component (PC1) is clearly associated with the solar EUV showing a 0.91 CCC with the E10.7 proxy while the PC1 EOFs remain relatively constant with latitude indicating that the solar EUV effects are relatively independent of latitude. The second principle component (PC2) is clearly associated with the SZA variation, showing strong correlations with the SZA and the concomitant density variations at latitudes away from the equator and with the PC2 EOFs having magnitudes near zero at the equator and maximum at high latitude. The magnitude of the variation of the response of the topside ionosphere to solar EUV variability is shown to be closely related to the composition. This is interpreted as the result of the effect of composition on the scale height in the topside ionosphere and the "pivot effect" in which the variation in density near the F2 peak is expected to be amplified by a factor of e at an altitude a scale height above the F2 peak. When the topside ionosphere is H+ dominated, DMSP may be much less than a scale height above the F2 peak while when it is O+ dominated, DMSP may be several scale heights above the F2 peak.
Byvank, T.; Banasek, J. T.; Potter, W. M.; ...
2017-12-07
We experimentally measure the effects of an applied axial magnetic field (B z) on laboratory plasma jets and compare experimental results with numerical simulations using an extended magnetohydrodynamics code. A 1 MA peak current, 100 ns rise time pulse power machine is used to generate the plasma jet. On application of the axial field, we observe on-axis density hollowing and a conical formation of the jet using interferometry, compression of the applied B z using magnetic B-dot probes, and azimuthal rotation of the jet using Thomson scattering. Experimentally, we find densities ≤ 5×10 17 cm -3 on-axis relative to jetmore » densities of ≥ 3×10 18 cm -3. For aluminum jets, 6.5 ± 0.5 mm above the foil, we find on-axis compression of the applied 1.0 ± 0.1 T B z to a total 2.4 ± 0.3 T, while simulations predict a peak compression to a total 3.4 T at the same location. On the aluminum jet boundary, we find ion azimuthal rotation velocities of 15-20 km/s, while simulations predict 14 km/s at the density peak. We discuss possible sources of discrepancy between the experiments and simulations, including: surface plasma on B-dot probes, optical fiber spatial resolution, simulation density floors, and 2D vs. 3D simulation effects. Lastly, this quantitative comparison between experiments and numerical simulations helps elucidate the underlying physics that determine the plasma dynamics of magnetized plasma jets.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Byvank, T.; Banasek, J. T.; Potter, W. M.
We experimentally measure the effects of an applied axial magnetic field (B z) on laboratory plasma jets and compare experimental results with numerical simulations using an extended magnetohydrodynamics code. A 1 MA peak current, 100 ns rise time pulse power machine is used to generate the plasma jet. On application of the axial field, we observe on-axis density hollowing and a conical formation of the jet using interferometry, compression of the applied B z using magnetic B-dot probes, and azimuthal rotation of the jet using Thomson scattering. Experimentally, we find densities ≤ 5×10 17 cm -3 on-axis relative to jetmore » densities of ≥ 3×10 18 cm -3. For aluminum jets, 6.5 ± 0.5 mm above the foil, we find on-axis compression of the applied 1.0 ± 0.1 T B z to a total 2.4 ± 0.3 T, while simulations predict a peak compression to a total 3.4 T at the same location. On the aluminum jet boundary, we find ion azimuthal rotation velocities of 15-20 km/s, while simulations predict 14 km/s at the density peak. We discuss possible sources of discrepancy between the experiments and simulations, including: surface plasma on B-dot probes, optical fiber spatial resolution, simulation density floors, and 2D vs. 3D simulation effects. Lastly, this quantitative comparison between experiments and numerical simulations helps elucidate the underlying physics that determine the plasma dynamics of magnetized plasma jets.« less
NASA Astrophysics Data System (ADS)
Adolph, David; Tingberg, Tobias; Ive, Tommy
2015-09-01
Plasma-assisted molecular beam epitaxy was used to grow ZnO(0001) layers on GaN(0001)/4H-SiC buffer layers deposited in the same growth chamber equipped with both N- and O-plasma sources. The GaN buffer layers were grown immediately before initiating the growth of ZnO. Using a substrate temperature of 445 °C and an O2 flow rate of 2.5 standard cubic centimeters per minute, we obtained ZnO layers with statistically smooth surfaces having a root-mean-square roughness of 0.3 nm and a peak-to-valley distance of 3 nm as revealed by atomic force microscopy. The full-width-at-half-maximum for x-ray rocking curves obtained across the ZnO(0002) and ZnO(10 1 bar 5) reflections was 198 and 948 arcsec, respectively. These values indicated that the mosaicity of the ZnO layer was comparable to the corresponding values of the underlying GaN buffer layer. Reciprocal space maps showed that the in-plane relaxation of the GaN and ZnO layers was 82% and 73%, respectively, and that the relaxation occurred abruptly during the growth. Room-temperature Hall-effect measurements revealed that the layers were inherently n-type and had an electron concentration of 1×1019 cm-3 and a Hall mobility of 51 cm2/V s.
Cardiovascular and metabolic adaptations in horses competing in cross-country events.
Muñoz, A; Riber, C; Santisteban, R; Rubio, M D; Agüera, E I; Castejón, F M
1999-01-01
The cardiovascular and metabolic response to two cross-country events (CC*: preliminary level and CC*** advanced level) were analysed in 8 male eventing horses (4 Anglo-Hunter and 4 Anglo-Arabian). This study focused on the establishment of the main metabolic pathways involved in the muscle energy resynthesis during the competitions. Heart rate (HR) was recorded throughout the CC events. Jugular venous blood samples were withdrawn before the warm-up period, immediately after the competitions and at 5 and 10 min in the recuperation period. The following haematological parameters were studied: red blood cells (RBC), packed cell volume (PCV), haemoglobin concentration (Hb), mean corpuscular volume (MCV), mean corpuscular haemoglobin (MCH), mean corpuscular haemoglobin concentration (MCHC), white blood cells (WBC), and number and percentages of lymphocytes (LYM) and granulocytes and monocytes (GRAN). One fraction of blood was centrifuged and, in plasma, lactate (LA), total plasma protein (TPP) and the rate of LA disappearance were determined. The competitions induced significant increases in RBC, Hb, PCV, MCV and TPP. Plasma LA response exceeded the anaerobic threshold of 4 mmol/l, reaching a maximum level of 13.3 mmol/l. HR ranged from 140 to more than 200 bpm, peaking at 230 bpm, revealing a limitation in the oxygen supply to the working muscles. It was concluded that muscle energy resynthesis during a CC event is provided both through oxidative processes and glycolysis with LA formation. Therefore, both stamina and power exercises are required for eventing horses.
NASA Astrophysics Data System (ADS)
Neretti, Gabriele; Cristofolini, Andrea; Borghi, Carlo A.
2014-04-01
The Electro-Hydro-Dynamics (EHD) interaction, induced in atmospheric pressure still air by a surface dielectric barrier discharge (DBD) actuator, had been experimentally studied. A plasma aerodynamic actuator array, able to produce a vectorized jet, with the induced airflow oriented toward the desired direction, had been developed. The array was constituted by a sequence of single surface DBD actuators with kapton as dielectric material. An ac voltage in the range of 0-6 kV peak at 15 kHz had been used. The vectorization had been obtained by feeding the upper electrodes with different voltages and by varying the electrical connections. The lower electrodes had been connected either to ground or to the high voltage source, to produce the desired jet orientation and to avoid plasma formation acting in an undesired direction. Voltage and current measurements had been carried out to evaluate waveforms and to estimate the active power delivered to the discharge. Schlieren imaging allowed to visualize the induced jet and to estimate its orientation. Pitot measurements had been performed to obtain velocity profiles for all jet configurations. A proportional relation between the jet deflection angle and the applied voltage had been found. Moreover, a linear relation had been obtained between the maximum speed in the jet direction and the applied voltage. The active power of the discharge is approximated by both a power law function and an exponential function of the applied voltage.
Analysis of laser produced plasmas of gold in the 1-7 nm region
NASA Astrophysics Data System (ADS)
Li, Bowen; Higashiguchi, Takeshi; Otsuka, Takamitsu; Yugami, Noboru; Dunne, Padraig; Kilbane, Deirdre; Sokell, Emma; O'Sullivan, Gerry
2014-04-01
Extreme ultraviolet (EUV) spectra from gold laser produced plasmas were recorded in the 1-7 nm region using two Nd:YAG lasers with pulse lengths of 150 ps and 10 ns, respectively, operating at a range of power densities. The maximum focused peak power density was 9.5 × 1013 W cm-2 for the former and 5.3 × 1012 W cm-2 for the latter. Two intense quasicontinuous intensity bands resulting from n = 4-n = 4 and n = 4-n = 5 unresolved transition arrays dominate the 4-5.5 and 1.5-3.6 nm regions of both spectra. Comparison with atomic structure calculations performed with the Cowan suite of atomic structure codes as well as consideration of previous experimental and theoretical results aided identification of the most prominent features in the spectra. For the ns spectrum, the highest ion stage that could be identified from the n = 4-n = 5 arrays was Au28+ while for the ps plasma the presence of significantly higher stages was deduced and lines due to 4d104f-4d94f2 transitions in Ag-like Au32+ give rise to the strongest observed features within the n = 4-n = 4 array while in the n = 4-n = 5 array it was possible to identify a number of previously unidentified spectral features as resulting from 4f-5g transitions in the spectra of Au XX to Au XXXIII.
Shunting arc plasma source for pure carbon ion beam.
Koguchi, H; Sakakita, H; Kiyama, S; Shimada, T; Sato, Y; Hirano, Y
2012-02-01
A plasma source is developed using a coaxial shunting arc plasma gun to extract a pure carbon ion beam. The pure carbon ion beam is a new type of deposition system for diamond and other carbon materials. Our plasma device generates pure carbon plasma from solid-state carbon material without using a hydrocarbon gas such as methane gas, and the plasma does not contain any hydrogen. The ion saturation current of the discharge measured by a double probe is about 0.2 mA∕mm(2) at the peak of the pulse.
Analysis of radiofrequency discharges in plasma
Kumar, Devendra; McGlynn, Sean P.
1992-01-01
Separation of laser optogalvanic signals in plasma into two components: (1) an ionization rate change component, and (2) a photoacoustic mediated component. This separation of components may be performed even when the two components overlap in time, by measuring time-resolved laser optogalvanic signals in an rf discharge plasma as the rf frequency is varied near the electrical resonance peak of the plasma and associated driving/detecting circuits. A novel spectrometer may be constructed to make these measurements. Such a spectrometer would be useful in better understanding and controlling such processes as plasma etching and plasma deposition.
Shunting arc plasma source for pure carbon ion beam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koguchi, H.; Sakakita, H.; Kiyama, S.
2012-02-15
A plasma source is developed using a coaxial shunting arc plasma gun to extract a pure carbon ion beam. The pure carbon ion beam is a new type of deposition system for diamond and other carbon materials. Our plasma device generates pure carbon plasma from solid-state carbon material without using a hydrocarbon gas such as methane gas, and the plasma does not contain any hydrogen. The ion saturation current of the discharge measured by a double probe is about 0.2 mA/mm{sup 2} at the peak of the pulse.
Plasma influence on the dispersion properties of finite-length, corrugated waveguides
NASA Astrophysics Data System (ADS)
Shkvarunets, A.; Kobayashi, S.; Weaver, J.; Carmel, Y.; Rodgers, J.; Antonsen, T. M., Jr.; Granatstein, V. L.; Destler, W. W.; Ogura, K.; Minami, K.
1996-03-01
We present an experimental study of the electromagnetic properties of transverse magnetic modes in a corrugated-wall cavity filled with a radially inhomogeneous plasma. The shifts of the resonant frequencies of a finite-length, corrugated cavity were measured as a function of the background plasma density and the dispersion diagram was reconstructed up to a peak plasma density of 1012 cm-3. Good agreement with a calculated dispersion diagram is obtained for plasma densities below 5×1011 cm-3.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dollar, Franklin; Matsuoka, Takeshi; McGuffey, Christopher
2010-11-04
Recent simulations show that an idealized, high intensity, short pulse laser can generate quasi-monoenergetic proton beams with energies over 100 MeV in an interaction with a thin film. However, most short pulse laser facilities with sufficient intensity have difficulty controlling the nanosecond and picosecond contrast necessary to realize such a regime. Experiments were performed to investigate proton and ion acceleration from a high contrast, short pulse laser by employing dual plasma mirrors along with a deformable mirror at the HERCULES laser facility at the Center for Ultrafast Optical Sciences, University of Michigan. Plasma mirrors were characterized, allowing a 50% throughputmore » with an intensity contrast increase of 105. The focal spot quality was also exceptional, showing a 1.1 micron full width at half maximum (FWHM) focal diameter. Experiments were done using temporally cleaned 30 TW, 32 fs pulses to achieve an intensity of up to 10{sup 21} Wcm{sup -2} on Si{sub 3}N{sub 4} and Mylar targets with thicknesses ranging 50 nm to 13 microns. Proton beams with energy spreads below 2 MeV were observed from all thicknesses, peaking with energies up to 10.3 MeV and an energy spread of 0.8 MeV. Similar narrow energy spreads were observed for oxygen, nitrogen, and carbon at the silicon nitride thickness of 50 nm with energies up to 24 MeV with an energy spread of 3 MeV, whereas the energy spread is greatly increased at a larger thickness. Maximum energies were confirmed with CR39 track detectors, while a Thomson ion spectrometer was used to gauge the monoenergetic nature of the beam.« less
Phase II Dose Escalation Study of Caspofungin for Invasive Aspergillosis ▿ §
Cornely, O. A.; Vehreschild, J. J.; Vehreschild, M. J. G. T.; Würthwein, G.; Arenz, D.; Schwartz, S.; Heussel, C. P.; Silling, G.; Mahne, M.; Franklin, J.; Harnischmacher, U.; Wilkens, A.; Farowski, F.; Karthaus, M.; Lehrnbecher, T.; Ullmann, A. J.; Hallek, M.; Groll, A. H.
2011-01-01
Our objective was to evaluate the maximum tolerated dose of caspofungin for invasive aspergillosis (IA). The safety and pharmacokinetics of escalating dosages of caspofungin were investigated in IA. Eight patients each received caspofungin 70, 100, 150, or 200 mg once a day (QD). Dose-limiting toxicity (DLT) was defined as the same non-hematological treatment-related adverse event of grade ≥4 in 2 of 8 patients or ≥3 in 4 of 8 patients in a cohort. A total of 46 patients (median age, 61 years; 21 female; 89% with hematological malignancies) received caspofungin (9, 8, 9, and 20 patients in the 70-, 100-, 150-, and 200-mg cohorts) for a median of 24.5 days. Plasma pharmacokinetics were linear across the investigated dosages and followed a two-compartment model, with weight as the covariate on clearance and sex as the covariate on central volume of distribution. Simulated peak plasma concentrations at steady state ranged from 14.2 to 40.6 mg/liter (28%), trough concentrations from 4.1 to 11.8 mg/liter (58%), and area under the concentration-time curve from 175 to 500 mg/liter/h (32%) (geometric mean, geometric coefficient of variation). Treatment was well tolerated without dose-limiting toxicity. The rate of complete or partial responses was 54.3%, and the overall mortality at 12-week follow-up was 28.3%. In first-line treatment of invasive aspergillosis, daily doses of up to 200 mg caspofungin were well tolerated and the maximum tolerated dose was not reached. Pharmacokinetics was linear. Response rates were similar to those previously reported for voriconazole and liposomal amphotericin. PMID:21911573
Modification of electromagnetic fields and plasma resistance by thermal effects in helicon plasmas
NASA Astrophysics Data System (ADS)
Kabir, M.; Niknam, A. R.
2017-05-01
The effects of the thermal motion of charged particles on physical characteristics of collisional helicon plasmas are investigated. First, the dielectric permittivity tensor of a helicon plasma is obtained by considering the thermal and collisional effects in the kinetic theory. Then, the electromagnetic wave and plasma resistance equations are presented and solved in a helicon plasma source with a Nagoya type III antenna. It is shown that by increasing the temperature of plasma electrons, the effective collision frequency is increased, and consequently, the peaks of resistance profiles are lowered and broadened.
NASA Technical Reports Server (NTRS)
Pfaff, R.; Freudenreich, H.; Klenzing, J.; Liebrecht, C.; Valladares, C.
2011-01-01
As solar activity has increased, the ionosphere F-peak has been elevated on numerous occasions above the C/NOFS satellite perigee of 400km. In particular, during the month of April, 2011, the satellite consistently journeyed below the F-peak whenever the orbit was in the region of the South Atlantic anomaly after sunset. During these passes, data from the electric field and plasma density probes on the satellite have revealed two types of instabilities which had not previously been observed in the C/NOFS data set (to our knowledge): The first is evidence for 400-500km-scale bottomside "undulations" that appear in the density and electric field data. In one case, these large scale waves are associated with a strong shear in the zonal E x B flow, as evidenced by variations in the meridional (outward) electric fields observed above and below the F-peak. These undulations are devoid of smaller scale structures in the early evening, yet appear at later local times along the same orbit associated with fully-developed spread-F with smaller scale structures. This suggests that they may be precursor waves for spread-F, driven by a collisional shear instability, following ideas advanced previously by researchers using data from the Jicamarca radar. A second new result (for C/NOFS) is the appearance of km-scale irregularities that are a common feature in the electric field and plasma density data that also appear when the satellite is below the F -peak at night. The vector electric field instrument on C/NOFS clearly shows that the electric field component of these waves is strongest in the zonal direction. These waves are strongly correlated with simultaneous observations of plasma density oscillations and appear both with, and without, evidence of larger-scale spread-F depletions. These km-scale, quasi-coherent waves strongly resemble the bottomside, sinusoidal irregularities reported in the Atmosphere Explorer satellite data set by Valladares et al. [JGR, 88, 8025, 1983]. We interpret these new observations in terms of fundamental plasma instabilities associated with the unstable, nighttime equatorial ionosphere.
Duarte, Felipe Coutinho Kullmann; Kolberg, Carolina; Barros, Rodrigo R; Silva, Vivian G A; Gehlen, Günter; Vassoler, Jakson M; Partata, Wania A
2014-05-01
This study was designed to assess the peak force of a manually operated chiropractic adjusting instrument, the Activator Adjusting Instrument 4 (AAI 4), with an adapter for use in animals, which has a 3- to 4-fold smaller contact surface area than the original rubber tip. Peak force was determined by thrusting the AAI 4 with the adapter or the original rubber tip onto a load cell. First, the AAI 4 was applied perpendicularly by a doctor of chiropractic onto the load cell. Then, the AAI 4 was fixed in a rigid framework and applied to the load cell. This procedure was done to prevent any load on the load cell before the thrust impulse. In 2 situations, trials were performed with the AAI 4 at all force settings (settings I, II, III, and IV, minimum to maximum, respectively). A total of 50000 samples per second over a period of 3 seconds were collected. In 2 experimental protocols, the use of the adapter in the AAI 4 increased the peak force only with setting I. The new value was around 80% of the maximum value found for the AAI 4. Nevertheless, the peak force values of the AAI 4 with the adapter and with the original rubber tip in setting IV were similar. The adapter effectively determines the maximum peak force value at force setting I of AAI 4. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Guminestskij, S. G.; Polianski, I. J.; Motrich, A. V.; Grunchuk, F. W.
2006-05-01
It is set that there are two maximums in UF- region absorption of vein blood plasma of a man: at λ = 235 nm and at λ = 280 nm. It is shown that there are the substantial changes of values of the optical density D comparative with controls (for donors) exactly in a maximum at development of sharp surgical diseases of organs of abdominal region λ = 280 nm, in that time as maximum at λ = 235 nm in this plan is not informing. Resulted results of researches of dynamics of changes of optical properties of vein blood plasma in UF- region of patients with pathology of abdominal region organs in after operating period (sharp appendicitis, sharp pancreatitis, intestinal impassability and others like that), which can have the diagnostic value.
A first-principles model for orificed hollow cathode operation
NASA Technical Reports Server (NTRS)
Salhi, A.; Turchi, P. J.
1992-01-01
A theoretical model describing orificed hollow cathode discharge is presented. The approach adopted is based on a purely analytical formulation founded on first principles. The present model predicts the emission surface temperature and plasma properties such as electron temperature, number densities and plasma potential. In general, good agreements between theory and experiment are obtained. Comparison of the results with the available related experimental data shows a maximum difference of 10 percent in emission surface temperature, 20 percent in electron temperature and 35 percent in plasma potential. In case of the variation of the electron number density with the discharge current a maximum discrepancy of 36 percent is obtained. However, in the case of the variation with the cathode internal pressure, the predicted electron number density is higher than the experimental data by a maximum factor of 2.
Near-fault peak ground velocity from earthquake and laboratory data
McGarr, A.; Fletcher, Joe B.
2007-01-01
We test the hypothesis that peak ground velocity (PGV) has an upper bound independent of earthquake magnitude and that this bound is controlled primarily by the strength of the seismogenic crust. The highest PGVs, ranging up to several meters per second, have been measured at sites within a few kilometers of the causative faults. Because the database for near-fault PGV is small, we use earthquake slip models, laboratory experiments, and evidence from a mining-induced earthquake to investigate the factors influencing near-fault PGV and the nature of its scaling. For each earthquake slip model we have calculated the peak slip rates for all subfaults and then chosen the maximum of these rates as an estimate of twice the largest near-fault PGV. Nine slip models for eight earthquakes, with magnitudes ranging from 6.5 to 7.6, yielded maximum peak slip rates ranging from 2.3 to 12 m/sec with a median of 5.9 m/sec. By making several adjustments, PGVs for small earthquakes can be simulated from peak slip rates measured during laboratory stick-slip experiments. First, we adjust the PGV for differences in the state of stress (i.e., the difference between the laboratory loading stresses and those appropriate for faults at seismogenic depths). To do this, we multiply both the slip and the peak slip rate by the ratio of the effective normal stresses acting on fault planes measured at 6.8 km depth at the KTB site, Germany (deepest available in situ stress measurements), to those acting on the laboratory faults. We also adjust the seismic moment by replacing the laboratory fault with a buried circular shear crack whose radius is chosen to match the experimental unloading stiffness. An additional, less important adjustment is needed for experiments run in triaxial loading conditions. With these adjustments, peak slip rates for 10 stick-slip events, with scaled moment magnitudes from -2.9 to 1.0, range from 3.3 to 10.3 m/sec, with a median of 5.4 m/sec. Both the earthquake and laboratory results are consistent with typical maximum peak slip rates averaging between 5 and 6 m/sec or corresponding maximum near-fault PGVs between 2.5 and 3 m/sec at seismogenic depths, independent of magnitude. Our ability to replicate maximum slip rates in the fault zones of earthquakes by adjusting the corresponding laboratory rates using the ratio of effective normal stresses acting on the fault planes suggests that the strength of the seismogenic crust is the important factor limiting the near-fault PGV.
Dual-mode characteristics of the Buneman instability in a bounded slab plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong, Woo-Pyo; Jung, Young-Dae, E-mail: ydjung@hanyang.ac.kr; Department of Applied Physics and Department of Bionanotechnology, Hanyang University, Ansan, Kyunggi-Do 426-791
2015-06-15
The dual-mode characteristics of the Buneman instability are investigated in a slab plasma, including the geometric effects. The dual symmetric and anti-symmetric dispersion modes of the Buneman instability are obtained by the plasma dielectric function with the spectral reflection conditions for the slab geometry. The result shows that the magnitudes of the growth rate for the symmetric mode are always greater than those for the anti-symmetric mode. It is also found that the geometric effect suppresses the position of the maximum growth rate for the Buneman instability in bounded slab plasmas since the maximum conditions for the symmetric and anti-symmetricmore » modes of the Buneman instability are given by 0.60« less
Flueck, Joelle Leonie; Bogdanova, Anna; Mettler, Samuel; Perret, Claudio
2016-04-01
Dietary nitrate has been reported to lower oxygen consumption in moderate- and severe-intensity exercise. To date, it is unproven that sodium nitrate (NaNO3(-); NIT) and nitrate-rich beetroot juice (BR) have the same effects on oxygen consumption, blood pressure, and plasma nitrate and nitrite concentrations or not. The aim of this study was to compare the effects of different dosages of NIT and BR on oxygen consumption in male athletes. Twelve healthy, well-trained men (median [minimum; maximum]; peak oxygen consumption: 59.4 mL·min(-1)·kg(-1) [40.5; 67.0]) performed 7 trials on different days, ingesting different nitrate dosages and placebo (PLC). Dosages were 3, 6, and 12 mmol nitrate as concentrated BR or NIT dissolved in plain water. Plasma nitrate and nitrite concentrations were measured before, 3 h after ingestion, and postexercise. Participants cycled for 5 min at moderate intensity and further 8 min at severe intensity. End-exercise oxygen consumption at moderate intensity was not significantly different between the 7 trials (p = 0.08). At severe-intensity exercise, end-exercise oxygen consumption was ~4% lower in the 6-mmol BR trial compared with the 6-mmol NIT (p = 0.003) trial as well as compared with PLC (p = 0.010). Plasma nitrite and nitrate concentrations were significantly increased after the ingestion of BR and NIT with the highest concentrations in the 12-mmol trials. Plasma nitrite concentration between NIT and BR did not significantly differ in the 6-mmol (p = 0.27) and in the 12-mmol (p = 0.75) trials. In conclusion, BR might reduce oxygen consumption to a greater extent compared with NIT.
Species diversity: Benthonic Foraminifera in Western North Atlantic
Buzas, M.A.; Gibson, T.G.
1969-01-01
Maximum species diversity occurs at abyssal depths of greater than 2500 meters. Other diversity peaks occur at depths of 35 to 45 meters and 100 to 200 meters. The peak at 35 to 45 meters is due to species equitability, whereas the other two peaks correspond to an increase in the number of species.
Sample Introduction Using the Hildebrand Grid Nebulizer for Plasma Spectrometry
1988-01-01
linear dynamic ranges, precision, and peak width were de- termined for elements in methanol and acetonitrile solutions. , (1)> The grid nebulizer was...FIA) with ICP-OES detection were evaluated. Detec- tion limits, linear dynamic ranges, precision, and peak width were de- termined for elements in...Concentration vs. Log Peak Area for Mn, 59 Cd, Zn, Au, Ni in Methanol (CMSC) 3-28 Log Concentration vs. Log Peak Area for Mn, 60 Cd, Au, Ni in
Stimulated Parametric Decay of Large Amplitude Alfv'en waves in the Large Plasma Device (LaPD)
NASA Astrophysics Data System (ADS)
Dorfman, S.; Carter, T.; Pribyl, P.; Tripathi, S. K. P.; van Compernolle, B.; Vincena, S.
2012-10-01
Alfv'en waves, the fundamental mode of magnetized plasmas, are ubiquitous in lab and space. While the linear behaviour of these waves has been extensively studied, non-linear effects are important in many real systems. In particular, a parametric decay process in which a large amplitude Alfv'en wave decays into an ion acoustic wave and backward propagating Alfv'en wave may be key to the spectrum of solar wind turbulence. The present laboratory experiments aim to stimulate this process by launching counter-propagating Alfv'en waves from antennas placed at either end of the Large Plasma Device (LaPD). The resulting beat response has many properties consistent with an ion acoustic wave including: 1) The beat amplitude peaks when the frequency difference between the two Alfv'en waves is near the value predicted by Alfv'en-ion acoustic wave coupling. 2) This peak beat frequency scales with antenna and plasma parameters as predicted by three wave matching. 3) The beat amplitude peaks at the same location as the magnetic field from the Alfv'en waves. 4) The beat wave is carried by the ions and propagates in the direction of the higher-frequency Alfv'en wave. Strong damping observed after the pump Alfv'en waves are turned off is under investigation.
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Bernauer, E. M.; Erti, A. C.
1995-01-01
Submaximal exercise (61+3% peak VO2) metabolism was measured before (AC day-2) and on bed rest day 4, 11, and 25 in 19 healthy men (32-42 yr) allocated into no exercise (NOE, N=5) control, and isotonic exercise (ITE, N=7)and isokinetic exercise (IKE, N=7) training groups. Training was conducting supine for two 30-min periods/d for 6 d/wk: ITE was 60-90% peak VO2: IKE was peak knee flexion-extension at 100 deg/s. Supine submaximal exercise 102 decreased significantly (*p<0.05) by 10.3%, with ITE and by 7.3%* with IKE; similar to the submaximal cardiac output (Q) change of -14.5%* (ITE) and -203%* (IKE), but different from change in peak VO2 (+1.4% with ITE and - 10.2%, with IKE) and plasma volume of -3.7% (ITE) and - 18.0% * (IKE). Thus, reduction of submaximal V02 during prolonged bed rest appears to respond to submaximal Q but is not related to change in peak VO2 or plasma volume.
Development of 600 kV triple resonance pulse transformer.
Li, Mingjia; Zhang, Faqiang; Liang, Chuan; Xu, Zhou
2015-06-01
In this paper, a triple-resonance pulse transformer based on an air-core transformer is introduced. The voltage across the high-voltage winding of the air-core transformer is significantly less than the output voltage; instead, the full output voltage appears across the tuning inductor. The maximum ratio of peak load voltage to peak transformer voltage is 2.77 in theory. By analyzing pulse transformer's lossless circuit, the analytical expression for the output voltage and the characteristic equation of the triple-resonance circuit are presented. Design method for the triple-resonance pulse transformer (iterated simulation method) is presented, and a triple-resonance pulse transformer is developed based on the existing air-core transformer. The experimental results indicate that the maximum ratio of peak voltage across the load to peak voltage across the high-voltage winding of the air-core transformer is approximately 2.0 and the peak output voltage of the triple-resonance pulse transformer is approximately 600 kV.
The metabolism of the anti-inflammatory drug eterylate in rat, dog and man.
Wood, S G; John, B A; Chasseaud, L F; Johnstone, I; Biggs, S R; Hawkins, D R; Priego, J G; Darragh, A; Lambe, R F
1983-12-01
Oral doses of 14C-eterylate were well absorbed by rat and man and excreted mainly in the urine (94% dose by rat in three days and 91% by man in five days). Oral doses to dogs were excreted in similar proportions in both the urine and faeces, although faecal 14C was probably derived in part, from biliary-excreted material. Peak plasma 14C and drug concn. were generally reached between one and three hours after oral doses. In humans, only two metabolites, salicylic acid and 4-acetamido-phenoxyacetic acid, were detected in plasma. The latter was cleared more rapidly than the former and hence plasma salicyclate concn. reached a peak (10.9 and 19.8 micrograms/ml in Subjects 1 and 2, respectively) and initially declined with a half-life of about two-three hours. Plasma 4-acetamidophenoxyacetic acid concn. reached a peak (4.3, 10.0 micrograms/ml, respectively) and declined with a half-life of about one hour. Tissue concn. of 14C were generally greater in dogs than in rats. Highest conc. occurred at three hours in dogs and at one hour in rats. Apart from those in the liver and kidneys, tissue concn. were lower than those in the corresponding plasma. Unchanged drug was not detected in urine or plasma of any species and was rapidly metabolized in human plasma. The major 14C components in human urine were identified as salicyluric acid and 4-acetamidophenoxyacetic acid; minor metabolites were salicylic acid, gentisic acid and paracetamol. These metabolites were also detected in rat urine albeit in different proportions to those in human urine. Dog urine contained less of these metabolites and a major proportion of the 14C was associated with relatively non-polar components. Although salicylic acid and 4-acetamidophenoxyacetic acid were the only major circulating metabolites in man and rat, dog plasma also contained the non-polar urine metabolites.
Walker, Dillon K.; Thaden, John J.; Wierzchowska-McNew, Agata; Engelen, Marielle P.K.J.; Deutz, Nicolaas E.P.
2016-01-01
Our objective was to develop a quick and simplified method for the determination of β-Hydroxy-β-methylbutyrate (HMB) and α-ketoisocaproic acid (KIC) concentrations and enrichments by GC/MS/MS to determine the turnover rate of HMB in humans. In experiment 1, we provided a pulse of L-[5,5,5-2H3]leucine to younger adults in the postabsorptive state then collected blood samples over a 4 h time period. In experiment 2, we provided a pulse of [3,4,methyl-13C3]HMB to older adults in the postabsorptive state then collected blood samples over a 3 h time period. Plasma concentrations of KIC and HMB and MPE of KIC and HMB were determined by GC/MS/MS. Plasma enrichment of leucine was determined by LC/MS/MS. To determine plasma enrichment of [5,5,5-2H3]HMB and [3,4,methyl-13C3]HMB, samples were derivatized using pentafluorobenzyl bromide and analyzed using chemical ionization mode. The final methods used included multiple reaction monitoring of transitions 117.3 > 59.3 for M + 0 and 120.3 > 59.3 for M + 3. In experiment 1, peak MPE of Leu peaked at 9.76% generating a peak MPE of KIC at 2.67% and a peak HMB MPE of 0.3%. In experiment 2, the rate of appearance for HMB was 0.66 μmol/kg ffm/h. We calculated that production of HMB in humans accounts for 0.66% of total leucine turnover. PMID:27856194
NASA Astrophysics Data System (ADS)
Xie, Jingjin; Chen, Qiang; Suresh, Poornima; Roy, Subrata; White, James F.; Mazzeo, Aaron D.
2017-05-01
This work describes disposable plasma generators made from metallized paper. The fabricated plasma generators with layered and patterned sheets of paper provide a simple and flexible format for dielectric barrier discharge to create atmospheric plasma without an applied vacuum. The porosity of paper allows gas to permeate its bulk volume and fuel plasma, while plasma-induced forced convection cools the substrate. When electrically driven with oscillating peak-to-peak potentials of ±1 to ±10 kV, the paper-based devices produced both volume and surface plasmas capable of killing microbes. The plasma sanitizers deactivated greater than 99% of Saccharomyces cerevisiae and greater than 99.9% of Escherichia coli cells with 30 s of noncontact treatment. Characterization of plasma generated from the sanitizers revealed a detectable level of UV-C (1.9 nWṡcm-2ṡnm-1), modest surface temperature (60 °C with 60 s of activation), and a high level of ozone (13 ppm with 60 s of activation). These results deliver insights into the mechanisms and suitability of paper-based substrates for active antimicrobial sanitization with scalable, flexible sheets. In addition, this work shows how paper-based generators are conformable to curved surfaces, appropriate for kirigami-like “stretchy” structures, compatible with user interfaces, and suitable for sanitization of microbes aerosolized onto a surface. In general, these disposable plasma generators represent progress toward biodegradable devices based on flexible renewable materials, which may impact the future design of protective garments, skin-like sensors for robots or prosthetics, and user interfaces in contaminated environments.
Paper-based plasma sanitizers.
Xie, Jingjin; Chen, Qiang; Suresh, Poornima; Roy, Subrata; White, James F; Mazzeo, Aaron D
2017-05-16
This work describes disposable plasma generators made from metallized paper. The fabricated plasma generators with layered and patterned sheets of paper provide a simple and flexible format for dielectric barrier discharge to create atmospheric plasma without an applied vacuum. The porosity of paper allows gas to permeate its bulk volume and fuel plasma, while plasma-induced forced convection cools the substrate. When electrically driven with oscillating peak-to-peak potentials of ±1 to ±10 kV, the paper-based devices produced both volume and surface plasmas capable of killing microbes. The plasma sanitizers deactivated greater than 99% of Saccharomyces cerevisiae and greater than 99.9% of Escherichia coli cells with 30 s of noncontact treatment. Characterization of plasma generated from the sanitizers revealed a detectable level of UV-C (1.9 nW⋅cm -2 ⋅nm -1 ), modest surface temperature (60 °C with 60 s of activation), and a high level of ozone (13 ppm with 60 s of activation). These results deliver insights into the mechanisms and suitability of paper-based substrates for active antimicrobial sanitization with scalable, flexible sheets. In addition, this work shows how paper-based generators are conformable to curved surfaces, appropriate for kirigami-like "stretchy" structures, compatible with user interfaces, and suitable for sanitization of microbes aerosolized onto a surface. In general, these disposable plasma generators represent progress toward biodegradable devices based on flexible renewable materials, which may impact the future design of protective garments, skin-like sensors for robots or prosthetics, and user interfaces in contaminated environments.
Goudah, Ayman M; Hasabelnaby, Sherifa M
2013-08-01
To determine the plasma disposition kinetics, absolute bioavailability, and milk concentrations of ceftazidime in healthy lactating female dromedary camels (Camelus dromedarius) following IV and IM administration of a single dose of 10 mg/kg (4.5 mg/lb). Prospective crossover study. 8 healthy adult lactating female dromedary camels. Camels received ceftazidime (10 mg/kg) IV and IM in a crossover study design with a 15-day washout period between treatments. Plasma and milk samples were collected at predetermined times for 48 hours after drug administration and analyzed by use of high-performance liquid chromatography. A 2-compartment open model best represented the plasma concentration-versus-time data after IV and IM administration of ceftazidime to camels. Plasma ceftazidime concentrations decreased biexponentially after IV administration with mean distribution and elimination half-lives of 0.3 hours and 2.85 hours, respectively. After IM administration, the mean maximum plasma concentration of ceftazidime was 32.43 μg/mL (1.21 hours after administration), mean elimination half-life was 3.20 hours, mean residence time was 4.84 hours, and mean systemic bioavailability was 93.72%. Distribution of ceftazidime from plasma to milk was rapid and extensive as indicated by the ratio of the area under the milk concentration-versus-time curve to the area under the plasma concentration-versus-time curve and the ratio of the maximum milk concentration to the maximum plasma concentration of ceftazidime after IV and IM administration. Results suggested that ceftazidime may be a useful treatment for female camels with mastitis caused by susceptible microorganisms.
NASA Astrophysics Data System (ADS)
Wang, Weixing; Brian, B.; Ethier, S.; Chen, J.; Startsev, E.; Diamond, P. H.; Lu, Z.
2015-11-01
A non-diffusive momentum flux connecting edge momentum sources/sinks and core plasma flow is required to establish the off-axis peaked ion rotation profile typically observed in ECH-heated DIII-D plasmas without explicit external momentum input. The understanding of the formation of such profile structures provides an outstanding opportunity to test the physics of turbulence driving intrinsic rotation, and validate first-principles-based gyrokinetic simulation models. Nonlinear, global gyrokinetic simulations of DIII-D ECH plasmas indicate a substantial ITG fluctuation-induced residual stress generated around the region of peaked toroidal rotation, along with a diffusive momentum flux. The residual stress profile shows an anti-gradient, dipole structure, which is critical for accounting for the formation of the peaked rotation profile. It is showed that both turbulence intensity gradient and zonal flow ExB shear contribute to the generation of k// asymmetry needed for residual stress generation. By balancing the simulated residual stress and the momentum diffusion, a rotation profile is calculated. In general, the radial structure of core rotation profile is largely determined by the residual stress profile, while the amplitude of core rotation depends on the edge toroidal rotation velocity, which is determined by edge physics and used as a boundary condition in our model. The calculated core rotation profile is consistent with the experimental measurements. Also discussed is the modification of turbulence-generated Reynolds stress on poloidal rotation in those plasmas. Work supported by U.S. DOE Contract DE-AC02-09-CH11466.
Tanner, Amy Vivien; Nielsen, Birthe Vejby; Allgrove, Judith
2014-01-01
The aim of this study was to examine the acute response to plasma and salivary cortisol and testosterone to three training protocols. Ten trained endurance athletes participated in three experimental trials, such as interval training (INT), tempo run (TEMP) and bodyweight-only circuit training (CIR), on separate days. Blood and saliva samples were collected pre- and 0, 15, 30 and 60 min post-exercise. Peak post-exercise salivary cortisol was higher than pre-exercise in all trials (P < 0.01). After INT, salivary cortisol remained elevated above pre-exercise than 60 min post-exercise. Salivary testosterone also increased post-exercise in all trials (P < 0.05). Plasma and salivary cortisol were correlated between individuals (r = 0.81, 0.73-0.88) and within individuals (r = 0.81, 0.73-0.87) (P < 0.01). Plasma and salivary testosterone was also correlated between (r = 0.57, 0.43-0.69) and within individuals (r = 0.60, 0.45-0.72), (P < 0.01). Peak cortisol and testosterone levels occurred simultaneously in plasma and saliva, but timing of post-exercise hormone peaks differed between trials and individuals. Further investigation is required to identify the mechanisms eliciting an increase in hormones in response to CIR. Furthermore, saliva is a valid alternative sampling technique for measurement of cortisol, although the complex, individual and situation dependent nature of the hormone response to acute exercise should be considered.
Rice, Nicklaus T.; Szlam, Fania; Varner, Jeffrey D.; Bernstein, Peter S.; Szlam, Arthur D.; Tanaka, Kenichi A.
2016-01-01
Background Thrombin generation (TG) is a pivotal process in achieving hemostasis. Coagulation profiles during pregnancy and early neonatal period are different from that of normal (non-pregnant) adults. In this ex vivo study, the differences in TG in maternal and cord plasma relative to normal adult plasma were studied. Methods Twenty consented pregnant women and ten consented healthy adults were included in the study. Maternal and cord blood samples were collected at the time of delivery. Platelet-poor plasma was isolated for the measurement of TG. In some samples, anti-FIXa aptamer, RB006, or a TFPI inhibitor, BAX499 were added to elucidate the contribution of intrinsic and extrinsic pathway to TG. Additionally, procoagulant and inhibitor levels were measured in maternal and cord plasma, and these values were used to mathematically simulate TG. Results Peak TG was increased in maternal plasma (393.6±57.9 nM) compared to adult and cord samples (323.2±38.9 nM and 209.9±29.5 nM, respectively). Inhibitory effects of RB006 on TG were less robust in maternal or cord plasma (52% vs. 12% respectively) than in adult plasma (81%). Likewise the effectiveness of BAX499 as represented by the increase in peak TG was much greater in adult (21%) than in maternal (10%) or cord plasma (12%). Further, BAX499 was more effective in reversing RB006 in adult plasma than in maternal or cord plasma. Ex vivo data were reproducible with the results of the mathematical simulation of TG. Conclusion Normal parturient plasma shows a large intrinsic pathway reserve for TG compared to adult and cord plasma, while TG in cord plasma is sustained by extrinsic pathway, and low levels of TFPI and AT. PMID:27196067
Kim, Beomjin; Park, Youngil; Kim, Seungho; Lee, Younggu; Park, Jongwook
2014-08-01
DPPZ showed UV-Vis. and PL maximum values of 412 and 638 nm, meaning the large stokes shift. Blue host compound, TAT was synthesized and used for co-mixed white emission. TAT exhibited UV-Vis. and PL maximum values of 403 nm and 445 nm in film state. Thus, when two compounds are used as co-mixed emitter in OLED device, there is no energy transfer from blue emission of TAT to DPPZ due to large stokes shift of DPPZ. Based on the PL result, it is available to realize two-colored white in PL and EL spectra. As a result of this, two-mixed compounds showed vivid their own PL emission peaks of 449 and 631 nm in film state. Also, white OLED device using two-mixed compounds system was fabricated. EL spectrum shows 457 and 634 nm peaks and two separate EL peaks, respectively. As the operation voltage is increased from 7 to 11 V, EL spectrum does not change the peak shape and maximum wavelength values. EL performance of white device showed 0.29 cd/A, 0.14 lm/W, and CIE (0.325, 0.195) at 7 V.
Body mass and antler development patterns of Rocky Mountain elk (Cervus elaphus nelsoni) in Michigan
Bender, L.C.; Carlson, E.; Schmitt, S.M.; Haufler, J.B.
2003-01-01
We documented mean and maximum body mass, mass accretion patterns and ander development patterns of Rocky Mountain elk in Michigan. Mean body mass of bulls averaged 9-11% heavier, and maximum body mass 23-27% heavier, in Michigan than in other Rocky Mountain elk populations. Mean live body mass of cows averaged 11% heavier in Michigan, but mean eviscerated body mass did not differ. Maximum body mass of cows was 10-24% heavier in Michigan. Body mass peaked at age 7.5 for bulls and 8.5 for cows, similar to other Rocky Mountain elk populations despite the greater body mass achieved in Michigan. Sexual dimorphism in bull and cow body mass increased until peak body mass was attained, whereupon bulls were ???38% heavier than cows. Antler development of bull elk peaked at age 10.5, comparable to other Rocky Mountain elk populations. Relations between antler development and body mass within age classes were highly variable, but generally weak. Greater body mass seen in Michigan, and the peaking of antler development well after body mass in bulls, suggested a phenotypic response to nutritional conditions that allow Rocky Mountain elk in Michigan to maximize the species growth potential.
Clinical pharmacokinetics of nisoldipine coat-core.
Heinig, R
1998-09-01
Nisoldipine, a calcium antagonist of the dihydropyridine type, is the active ingredient of the controlled release nisoldipine coat-core (CC) formulation. In humans, the absorption from nisoldipine CC occurs across the entire gastrointestinal tract with an increase in bioavailability in the colon because of the lower concentrations of metabolising enzymes in the distal gut wall. Although nisoldipine is almost completely absorbed, its absolute bioavailability from the CC tablet is only 5.5%, as a result of significant first-pass metabolism in the gut and liver. Nisoldipine is a high-clearance drug with substantial interindividual and relatively lower intraindividual variability in pharmacokinetics, dependent on liver blood flow. Nisoldipine is highly (> 99%) protein bound. Its elimination is almost exclusively via the metabolic route and renal excretion of metabolites dominates over excretion in the faeces. Although nisoldipine is administered as a racemic mixture, its plasma concentrations are almost entirely caused by the eutomer as a result of highly stereoselective intrinsic clearance. Nisoldipine CC demonstrates linear pharmacokinetics in the therapeutic dose range and its steady-state pharmacokinetics are predictable from single dose data. Steady-state is reached with the second dose when the drug is given once daily and the peak-trough fluctuations in plasma concentration is minimal. Plasma-concentrations of nisoldipine increase with age. Careful dose titration according to individual clinical response is recommended in the elderly. Nisoldipine CC should not be used in patients with liver cirrhosis, though dosage adjustments in patients with renal impairment are not necessary. Inter-ethnic differences in its pharmacokinetics are not evident. Owing to inhibition of metabolising enzymes, a small dosage adjustment decrement for nisoldipine CC may be required when it is given in combination with cimetidine. Concomitant ingestion of nisoldipine with grapefruit juice should be avoided. Inducers of cytochrome P450 (CYP) 3A4, e.g. rifampicin (rifampin) and phenytoin should not be combined with nisoldipine CC, as they may reduce its bioavailability and result in a loss of efficacy. The concomitant use of other drugs which may produce marked induction or inhibition of CYP3A4 is contraindicated. Concomitant intake of the CC tablet with high fat, high calorie foods resulted in an increase in the maximum plasma concentrations of nisoldipine. The 'food-effect' can be avoided by administration of the CC tablet up to 30 minutes before the intake of food [corrected]. Plasma concentrations of nisoldipine are related to its antihypertensive effect via a maximum effect model. Nisoldipine CC once daily produce reductions in blood pressure which are maintained over 24 hours in the absence of relevant effects on heart rate.
NASA Astrophysics Data System (ADS)
Nunome, Yoko; Kodama, Kenji; Ueki, Yasuaki; Yoshiie, Ryo; Naruse, Ichiro; Wagatsuma, Kazuaki
2018-01-01
This study describes an ionization source for mass analysis, consisting of glow discharge plasma driven by a pulsed direct-current voltage for soft plasma ionization, to detect toxic volatile organic compounds (VOCs) rapidly and easily. The novelty of this work is that a molecular adduct ion, in which the parent molecule attaches with an NO+ radical, [M + NO]+, can be dominantly detected as a base peak with little or no fragmentation of them in an ambient air plasma at a pressure of several kPa. Use of ambient air as the discharge plasma gas is suitable for practical applications. The higher pressure in an ambient air discharge provided a stable glow discharge plasma, contributing to the soft ionization of organic molecules. Typical mass spectra of VOCs toluene, benzene, o-xylene, chlorobenzene and n-hexane were observed as [M + NO]+ adduct ion whose peaks were detected at m/z 122, 108, 136, 142 and 116, respectively. The NO generation was also confirmed by emission bands of NO γ-system. The ionization reactions were suggested, such that NO+ radical formed in an ambient air discharge could attach with the analyte molecule.
Plasma waves associated with the AMPTE artificial comet
NASA Technical Reports Server (NTRS)
Gurnett, D. A.; Anderson, R. R.; Haeusler, B.; Haerendel, G.; Bauer, O. H.
1985-01-01
Numerous plasma wave effects were detected by the AMPTE/IRM spacecraft during the artificial comet experiment on December 27, 1984. As the barium ion cloud produced by the explosion expanded over the spacecraft, emissions at the electron plasma frequency and ion plasma frequency provided a determination of the local electron density. The electron density in the diamagnetic cavity produced by the ion cloud reached a peak of more than 5 x 10 to the 5th per cu cm, then decayed smoothly as the cloud expanded, varying approximately as t exp-2. As the cloud began to move due to interactions with the solar wind, a region of compressed plasma was encountered on the upstream side of the diamagnetic cavity. The peak electron density in the compression region was about 1.5 x 10 to the 4th per cu cm. Later, a very intense (140 mVolt/m) broadband burst of electrostatic noise was encountered on the sunward side of the compression region. This noise has characteristics very similar to noise observed in the earth's bow shock, and is believed to be a shocklike interaction produced by an ion beam-plasma instability between the nearly stationary barium ions and the streaming solar wind protons.
Crevoisier, C; Delisle, M C; Joseph, I; Foletti, G
2003-01-01
The objective was to assess the single-dose pharmacokinetics of clonazepam following i.m., p.o. and i.v. administration. In an open-label, three-way crossover study, 12 healthy volunteers were randomized to receive a single dose of 2 mg clonazepam either by the i.m., p.o. or i.v. route. Serial blood samples were collected up to 120 h after drug administration. Plasma concentrations of clonazepam were determined by electron-capture gas-liquid chromatography. The absorption rates of clonazepam after i.m. and p.o. administration of clonazepam were significantly different from each other, as reflected by the respective mean values of maximum plasma concentration (C(max) 11.0 vs. 14.9 ng.ml(-1)) and time to reach maximum concentration (t(max) 3.1 vs. 1.7 h). Secondary plasma peaks of clonazepam were observed in 9 volunteers after i.m. injection (C(max) 9.9 ng.ml(-1); t(max) 10.4 h). A comparison of the area under the plasma concentration-time curves (AUC) shows that the i.m. route is equivalent to the oral route (AUC(0- infinity ) 620 vs. 561 ng.h.ml(-1)). Clonazepam was almost completely absorbed after i.m. and p.o. administration, as shown by the mean absolute bioavailability of 93 and 90%, respectively. No significant differences existed between the elimination half-lives (i.v. 38.0 h; i.m. 43.6 h; p.o. 39.0 h). The average clearance and volume of distribution (V(Z)) were 55 ml.min(-1) and 180 liters, respectively. In conclusion, the observed differences in C(max) and t(max) after i.m. and p.o. administration were consistent with a slower absorption rate of clonazepam after i.m. injection. The systemic exposure to clonazepam was not affected by the route of extravascular administration. Statistical evaluation of these kinetic data showed differences in the absorption rate, so that clonazepam given by the i.m. route is not bioequivalent to the oral route. On the basis of the results of this study, we would recommend the same i.m. and p.o. dose in epileptic patients, but therapeutic response would be expected to be less predictable and to occur later in the case of i.m. administration. Copyright 2003 S. Karger AG, Basel
Anderson, Tom; Schein, Philip S.; McMenamin, Mary G.; Cooney, David A.
1974-01-01
The diabetogenic activity of streptozotocin has been correlated with a reduction in pyridine nucleotide synthesis in the mouse pancreatic islet. To determine the specificity of this reduction for diabetogenicity, a comparative study of streptozotocin, its cytotoxic moiety, 1-methyl-1-nitrosourea, and alloxan was performed. Streptozotocin administered intraperitoneally (i.p.) producd a dose-related reduction in islet NAD which was proportional to the degree of diabetogenicity. A diabetogenic dose, 200 mg/kg, attained a peak plasma N-nitroso intact streptozotocin concentration of 0.224 μmol/ml and reduced the mean islet NAD from a control of 0.78 to 0.15 pmol. At borderline, 150 mg/kg, and nondiabetogenic, 100 mg/kg, doses, plasma concentrations reached 0.161 and 0.136 μmol/ml, and NAD was 0.36 and 0.86 pmol/islet, respectively. 1-Methyl-1-nitrosourea, 100 mg/kg, attained a maximum N-nitroso intact 1-methyl-1-nitrosourea concentration of 0.162 μmol/ml and reduced the mean NAD to 0.58 pmol/islet, and was nondiabetogenic; 200 mg/kg attained a peak plasma concentration of 0.344 μmol/ml and depressed NAD to 0.38 pmol/islet, and was inconsistently diabetogenic. Islet NAD of 0.4 pmol/islet or greater is required for integrity of the beta cell. A diabetogenic dose of alloxan, 500 mg/kg, did not depress NAD, 0.85 pmol/islet, therefore confirming that its mechanism of diabetogenicity differs from that of streptozotocin. In vivo uptake of [methyl-14C]streptozotocin by islets was 3.8 times that of [methyl-14C]-1-methyl-1-nitrosourea, whereas uptake by the exocrine pancreas favored 1-methyl-1-nitrosourea over streptozotocin 2.4:1. The decreased islet uptake of 1-methyl-1-nitrosourea correlates with the 3.5 times increased molar dosage required to produce islet NAD depression comparable to that of streptozotocin, 150 mg/kg. These studies indicate that the glucose carrier of streptozotocin facilitates uptake of its cytotoxic group, 1-methyl-1-nitrosourea, into islets. PMID:4369217
RADIOACTIVE IRON ABSORPTION BY GASTRO-INTESTINAL TRACT
Hahn, P. F.; Bale, W. F.; Ross, J. F.; Balfour, W. M.; Whipple, G. H.
1943-01-01
Iron absorption is a function of the gastro-intestinal mucosal epithelium. The normal non-anemic dog absorbs little iron but chronic anemia due to blood loss brings about considerable absorption—perhaps 5 to 15 times normal. In general the same differences are observed in man (1). Sudden change from normal to severe anemia within 24 hours does not significantly increase iron absorption. As the days pass new hemoglobin is formed. The body iron stores are depleted and within 7 days iron absorption is active, even when the red cell hematocrit is rising. Anoxemia of 50 per cent normal oxygen concentration for 48 hours does not significantly enhance iron absorption. In this respect it resembles acute anemia. Ordinary doses of iron given 1 to 6 hours before radio-iron will cause some "mucosa block"—that is an intake of radio-iron less than anticipated. Many variables which modify peristalsis come into this reaction. Iron given by vein some days before the dose of radio-iron does not appear to inhibit iron absorption. Plasma radio-iron absorption curves vary greatly. The curves may show sharp peaks in 1 to 2 hours when the iron is given in an empty stomach but after 6 hours when the radio-iron is given with food. Duration time of curves also varies widely, the plasma iron returning to normal in 6 to 12 hours. Gastric, duodenal, or jejunal pouches all show very active absorption of iron. The plasma concentration peak may reach a maximum before the solution of iron is removed from the gastric pouch—another example of "mucosa block." Absorption and distribution of radio-iron in the body of growing pups give very suggestive experimental data. The spleen, heart, upper gastro-intestinal tract, marrow, and pancreas show more radio-iron than was expected. The term "physiological saturation" with iron may be applied to the gastro-intestinal mucosal epithelium and explain one phase of acceptance or refusal of ingested iron. Desaturation is a matter of days not hours, whereas saturation may take place within 1 to 2 hours. We believe this change is a part of the complex protein metabolism of the cell. PMID:19871320
Nasser, Azmi F; Heidbreder, Christian; Liu, Yongzhen; Fudala, Paul J
2015-08-01
Suboxone(®) is a sublingual tablet of buprenorphine/naloxone, approved for the treatment of opioid dependence. The objective of this study was to quantify the impact of hepatic impairment or hepatitis C virus infection on the pharmacokinetics of buprenorphine or naloxone and their major metabolites. Forty-three subjects received a single dose of a Suboxone 2.0/0.5-mg tablet. Blood samples were collected up to 168 h and pharmacokinetic parameters were calculated using non-compartmental analysis. Statistical analysis was performed using analysis of covariance. Pharmacokinetic parameters were derived from 33 subjects. Compared with healthy subjects, for patients with severe hepatic impairment, total and peak exposures increased to 281.4 % [90 % confidence interval 187.1-423.3] and 171.8 % [117.9-250.2] for buprenorphine, 1401.9 % [707.6-2777.5] and 1129.8 % [577.2-2211.4] for naloxone. For moderate hepatic impaired subjects, naloxone total and peak exposure increased to 317.6 % [164.9-611.5] and 270.0 % [141.9-513.9]. For buprenorphine, only total exposure increased to 163.9 % [110.8-242.3]. Changes in maximum observed plasma concentration, area under the plasma concentration-time curve from time zero to time of the last quantifiable concentration, and area under the plasma concentration-time curve from time zero to infinity of buprenorphine or naloxone in subjects with mild hepatic impairment or with hepatitis C virus infection were within twofold of those of healthy subjects. Serious adverse events were not observed. Severe and moderate hepatic impairment significantly increased exposure of naloxone and to a lesser extent of buprenorphine. Therefore, buprenorphine/naloxone combination products should generally be avoided in patients with severe hepatic impairment and may not be appropriate for patients with moderate hepatic impairment. However, buprenorphine/naloxone products may be used with caution for maintenance treatment in patients with moderate hepatic impairment who have initiated treatment on a buprenorphine product without naloxone [Registered at ClinicalTrials.gov as NCT01846455].
NASA Astrophysics Data System (ADS)
Xiang, Suyun; Wang, Wei; Xiang, Bingren; Deng, Haishan; Xie, Shaofei
2007-05-01
The periodic modulation-based stochastic resonance algorithm (PSRA) was used to amplify and detect the weak liquid chromatography-mass spectrometry (LC-MS) signal of granisetron in plasma. In the algorithm, the stochastic resonance (SR) was achieved by introducing an external periodic force to the nonlinear system. The optimization of parameters was carried out in two steps to give attention to both the signal-to-noise ratio (S/N) and the peak shape of output signal. By applying PSRA with the optimized parameters, the signal-to-noise ratio of LC-MS peak was enhanced significantly and distorted peak shape that often appeared in the traditional stochastic resonance algorithm was corrected by the added periodic force. Using the signals enhanced by PSRA, this method extended the limit of detection (LOD) and limit of quantification (LOQ) of granisetron in plasma from 0.05 and 0.2 ng/mL, respectively, to 0.01 and 0.02 ng/mL, and exhibited good linearity, accuracy and precision, which ensure accurate determination of the target analyte.
Castel-Branco, M M; Figueiredo, I V; Falcão, A C; Macedo, T R A; Caramona, M M
2002-10-01
Given that administration vehicles and drug formulations can affect drug bioavailability, their influence on the pharmacokinetic profile of lamotrigine (LTG), a new-generation anti-epileptic drug, was studied in rats. Three different formulations administered intraperitoneally at a dose of 10 mg/kg were used: (1) LTG suspended in a 0.25% methylcelulose solution, (2) LTG dissolved in a 50% propylene glycol solution, and (3) LTG isethionate dissolved in distilled water. Plasma and brain homogenate levels were determined in order to evaluate vehicle-dependent drug absorption. The results demonstrated rapid absorption of LTG when it was administered as an aqueous solution, in contrast to a slower and more erratic absorption after the injection of either the lipophilic solution or the suspension. A plasma peak was achieved 15 min post-dose with the aqueous solution, with a brain peak being achieved 15 min later, while with the other formulations both plasma and brain homogenate peaks were reached 2 h after LTG administration. This study suggests that LTG isethionate dissolved in distilled water is the most suitable formulation for successful LTG pharmacokinetic studies in rats.
The structure of high-temperature solar flare plasma in non-thermal flare models
NASA Technical Reports Server (NTRS)
Emslie, A. G.
1985-01-01
Analytic differential emission measure distributions have been derived for coronal plasma in flare loops heated both by collisions of high-energy suprathermal electrons with background plasma, and by ohmic heating by the beam-normalizing return current. For low densities, reverse current heating predominates, while for higher densities collisional heating predominates. There is thus a minimum peak temperature in an electron-heated loop. In contrast to previous approximate analyses, it is found that a stable reverse current can dominate the heating rate in a flare loop, especially in the low corona. Two 'scaling laws' are found which relate the peak temperature in the loop to the suprathermal electron flux. These laws are testable observationally and constitute a new diagnostic procedure for examining modes of energy transport in flaring loops.
Effect of injection-gas concentration on the electron beam quality from a laser-plasma accelerator
NASA Astrophysics Data System (ADS)
Mirzaie, Mohammad; Zhang, Guobo; Li, Song; Gao, Kai; Li, Guangyu; Ain, Quratul; Hafz, Nasr A. M.
2018-04-01
By using 25-45 TW ultra-short (30 fs) laser pulses, we report on the effect of the injection gas concentration on the quality of electron beams generated by a laser-driven plasma wakefield acceleration employing the ionization-injection. For a plasma formed from helium-nitrogen gas mixture and depending on the concentration of the nitrogen gas, we could distinguish a clear trend for the quality of the generated electron beams in terms of their peak energy, energy-spread, divergence angle, and beam charge. The results clearly showed that the lower the nitrogen concentration, the better the quality (higher peak energy, smaller energy spread, and smaller emittance) of the generated electron beams. The results are in reasonable agreement with two-dimensional particle-in-cell simulations.
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Ertl, A. C.; Bernauer, E. M.
1996-01-01
BACKGROUND: Maintaining intermediary metabolism is necessary for the health and well-being of astronauts on long-duration spaceflights. While peak oxygen uptake (VO2) is consistently decreased during prolonged bed rest, submaximal VO2 is either unchanged or decreased. METHODS: Submaximal exercise metabolism (61 +/- 3% peak VO2) was measured during ambulation (AMB day-2) and on bed rest days 4, 11, and 25 in 19 healthy men (32-42 yr) allocated into no exercise (NOE, N = 5) control, and isotonic exercise (ITE, N = 7) and isokinetic exercise (IKE, N = 7) training groups. Exercise training was conducted supine for two 30-min periods per day for 6 d per week: ITE training was intermittent at 60-90% peak VO2; IKE training was 10 sets of 5 repetitions of peak knee flexion-extension force at a velocity of 100 degrees s-1. Cardiac output was measured with the indirect Fick CO2 method, and plasma volume with Evans blue dye dilution. RESULTS: Supine submaximal exercise VO2 decreased significantly (*p < 0.05) by 10.3%* with ITE and by 7.3%* with IKE; similar to the submaximal cardiac output decrease of 14.5%* (ITE) and 20.3%* (IKE), but different from change in peak VO2 (+1.4% with ITE and -10.2%* with IKE) and decrease in plasma volume of -3.7% (ITE) and -18.0%* (IKE). Reduction of submaximal VO2 during bed rest correlated 0.79 (p < 0.01) with submaximal Qc, but was not related to change in peak VO2 or plasma volume. CONCLUSION: Reduction in submaximal oxygen uptake during prolonged bed rest is related to decrease in exercise but not resting cardiac output; perturbations in active skeletal muscle metabolism may be involved.
Zoli, A; Bosello, S; Comerci, G; Galiano, N; Forni, A; Loperfido, F; Ferraccioli, G F
2017-01-01
Rheumatoid arthritis (RA) is associated with an increased risk of myocardial infarction and congestive heart failure. In RA patients, elevated NT-proBNP levels have been reported to be a prognostic marker of left ventricular dysfunction. In this study, we evaluated cardiorespiratory functional capacity and NT-proBNP levels before and during cardiopulmonary exercise test in early RA (ERA) patients. Twenty ERA patients and 10 healthy controls were studied by color Doppler echocardiography to evaluate ventricular systolic and diastolic function. Arterial stiffness and wave reflections were quantified non-invasively using applanation tonometry of the radial artery. Cardiopulmonary treadmill test was performed to measure peak VO 2 and VE/VCO 2 parameters. NT-proBNP plasma levels were measured before and at the exercise peak during cardiopulmonary exercise. The peak oxygen uptake [VO 2 (ml/min/kg)], the ventilatory equivalents for carbon dioxide (EqCO 2 ), respiratory exchange ratio and arterial stiffness were similar between patients and controls during cardiopulmonary exercise test. Basal and peak cardiopulmonary exercise NT-proBNP plasma levels were comparable in ERA patients with respect to healthy controls. When we analyzed patients according to disease characteristics and cardiovascular risk factors, ERA patients with high disease activity, BMI > 25 kg/m 2 and ACPA positivity presented significantly higher baseline and exercise peak NT-proBNP levels. Cardiorespiratory function is preserved in patients with recent onset of rheumatoid arthritis. The increased basal and exercise peak NT-proBNP plasma levels in patients with negative disease prognostic factors represent a possible marker to stratify the cardiovascular risk in patients with early rheumatoid arthritis.
Role of atrial natriuretic peptide in systemic responses to acute isotonic volume expansion
NASA Technical Reports Server (NTRS)
Watenpaugh, Donald E.; Yancy, Clyde W.; Buckey, Jay C.; Lane, Lynda D.; Hargens, Alan R.; Blomqvist, C. G.
1992-01-01
A hypothesis is proposed that a temporal relationship exists between increases in cardiac filling pressure and plasma artrial natriuretic peptide (ANP) concentration and also between ANP elevation and vasodilation, fluid movement from plasma to interstitium, and increased urine volume (UV). To test the hypothesis, 30 ml/kg isotonic saline were infused in supine male subjects over 24 min and responses were monitored for 3 h postinfusion. Results show that at end infusion, mean arterial pressure (RAP), heart rate and plasma volume exhibited peak increases of 146, 23, and 27 percent, respectively. Mean plasma ANP and UV peaked (45 and 390 percent, respectively) at 30 min postinfusion. Most cardiovascular variables had returned toward control levels by 1 h postinfusion, and net reabsorption of extravascular fluid ensued. It is concluded that since ANP was not significantly increased until 30 min postinfusion, factors other than ANP initiate responses to intravascular fluid loading. These factors include increased vascular pressures, baroreceptor-mediated vasolidation, and hemodilution of plasma proteins. ANP is suggested to mediate, in part, the renal response to saline infusion.
DiMarco, Anthony F.; Kowalski, Krzysztof E.; Geertman, Robert T.; Hromyak, Dana R.
2009-01-01
Objective Evaluation of the capacity of lower thoracic spinal cord stimulation (SCS) to activate the expiratory muscles and generate large airway pressures and high peak airflows characteristic of cough, in subjects with tetraplegia. Design Clinical trial. Setting In-patient hospital setting for electrode insertion; out-patient setting for measurement of respiratory pressures; home setting for application of SCS. Participants Subjects (N = 9; 8 men, 1 woman) with cervical spinal cord injury and weak cough. Intervention(s) A fully implantable electrical stimulation system was surgically placed in each subject. Partial hemilaminectomies were made to place single-disc electrodes in the epidural space at the T9, T11 and L1 spinal levels. A radiofrequency receiver was placed in the subcutaneous pocket over the anterior portion of the chest wall. Electrode wires were tunneled subcutaneously and connected to the receiver. Stimulation was applied by activating a small portable external stimulus controller box powered by a rechargeable battery to each electrode lead alone and in combination. Main Outcome Measure(s) Airway pressure and peak airflow generation achieved with SCS. Results Supramaximal SCS resulted in large airway pressures and high peak airflow rates during stimulation at each electrode lead. Maximum airway pressures and peak airflow rates were achieved with combined stimulation of any 2 leads. At total lung capacity, mean maximum airway pressure generation and peak airflow rates were 137 ± 30 cmH2O (mean ± SE) and 8.6 ± 1.8 (mean ± SE) L/s, respectively. Conclusions Lower thoracic SCS results in near maximum activation of the expiratory muscles and the generation of high positive airway pressures and peak airflow rates in the range of those observed with maximum cough efforts in normal individuals. PMID:19406289
Cardiorespiratory responses of a dance session designed for older women: A cross sectional study.
Rodrigues-Krause, Josianne; Farinha, Juliano Boufleur; Ramis, Thiago Rozales; Boeno, Francesco Pinto; Dos Santos, Gabriela Cristina; Krause, Mauricio; Reischak-Oliveira, Alvaro
2018-06-04
Dancing has been increasingly used as a type of exercise intervention to improve cardiovascular fitness of older people. However, it is unclear which may be the exercise intensity of the dance sessions. To describe cardiorespiratory responses of a dance session for older women, and to identify intensity zones in relation to peak oxygen consumption (VO 2 peak), first and second ventilatory thresholds (VT1 and VT2). Ten women (66 ± 5 yrs., BMI 27 ± 4) were examined on three occasions: Familiarization, maximum effort and dance sessions. Incremental treadmill test: 5 km/h, 2% slope each min, until maximum effort. Dance class (60 min): warm-up (20 min), across-the-floor (10 min), choreography (15 min), show (10 min) and cool-down (5 min). Ventilatory parameters were measured continuously (breath-by-breath). VO 2 (mL·kg -1 ·min -1 ): Maximum effort: VO 2 peak (23.3 ± 4.3), VT1 (17.2 ± 3.5) and VT2 (20.9 ± 3.4). Dancing: warm-up (12.8 ± 2.4, ~55%VO 2 peak), across-the-floor (14.2 ± 2.4 ~62%VO 2 peak), choreography (14.6 ± 3.2 ~63%VO 2 peak) and show (16.1 ± 3.3, ~69% VO 2 peak). Show was similar to VT1. Cardiorespiratory demands of a dance class for older women are at low aerobic intensity. Show was similar to VT1, indicating that a dance class may be modulated to improve aerobic fitness, at least at initial stages of training. Copyright © 2018 Elsevier Inc. All rights reserved.
Simulations of cataclysmic outburst floods from Pleistocene Glacial Lake Missoula
Denlinger, Roger P.; O'Connell, D. R. H.
2009-01-01
Using a flow domain that we constructed from 30 m digital-elevation model data of western United States and Canada and a two-dimensional numerical model for shallow-water flow over rugged terrain, we simulated outburst floods from Pleistocene Glacial Lake Missoula. We modeled a large, but not the largest, flood, using initial lake elevation at 1250 m instead of 1285 m. Rupture of the ice dam, centered on modern Lake Pend Oreille, catastrophically floods eastern Washington and rapidly fills the broad Pasco, Yakima, and Umatilla Basins. Maximum flood stage is reached in Pasco and Yakima Basins 38 h after the dam break, whereas maximum flood stage in Umatilla Basin occurs 17 h later. Drainage of these basins through narrow Columbia gorge takes an additional 445 h. For this modeled flood, peak discharges in eastern Washington range from 10 to 20 × 106 m3/s. However, constrictions in Columbia gorge limit peak discharges to 6 m3/s and greatly extend the duration of flooding. We compare these model results with field observations of scabland distribution and high-water indicators. Our model predictions of the locations of maximum scour (product of bed shear stress and average flow velocity) match the distribution of existing scablands. We compare model peak stages to high-water indicators from the Rathdrum-Spokane valley, Walulla Gap, and along Columbia gorge. Though peak stages from this less-than-maximal flood model attain or exceed peak-stage indicators along Rathdrum-Spokane valley and along Columbia gorge, simulated peak stages near Walulla Gap are 10–40 m below observed peak-stage indicators. Despite this discrepancy, our match to field observations in most of the region indicates that additional sources of water other than Glacial Lake Missoula are not required to explain the Missoula floods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Young-Do; Lee, Hyo-Chang; Chung, Chin-Wook
Correlations between the external discharge parameters (the driving frequency ω and the chamber dimension R) and plasma characteristics (the skin depth δ and the electron-neutral collision frequency ν{sub m}) are studied using the transformer circuit model [R. B. Piejak et al., Plasma Sources Sci. Technol. 1, 179 (1992)] when the absorbed power is maximized in an inductively coupled plasma. From the analysis of the transformer circuit model, the maximum power transfer conditions, which depend on the external discharge parameters and the internal plasma characteristics, were obtained. It was found that a maximum power transfer occurs when δ≈0.38R for the dischargemore » condition at which ν{sub m}/ω≪1, while it occurs when δ≈√(2)√(ω/ν{sub m})R for the discharge condition at which ν{sub m}/ω≫1. The results of this circuit analysis are consistent with the stable last inductive mode region of an inductive-to-capacitive mode transition [Lee and Chung, Phys. Plasmas 13, 063510 (2006)], which was theoretically derived from Maxwell's equations. Our results were also in agreement with the experimental results. From this work, we demonstrate that a simple circuit analysis can be applied to explain complex physical phenomena to a certain extent.« less
Plasma studies of the permanent magnet electron cyclotron resonance ion source at Peking University.
Ren, H T; Peng, S X; Xu, Y; Zhao, J; Lu, P N; Chen, J; Zhang, A L; Zhang, T; Guo, Z Y; Chen, J E
2014-02-01
At Peking University (PKU) we have developed several 2.45 GHz Permanent Magnet Electron Cyclotron Resonance ion sources for PKUNIFTY, SFRFQ, Coupled RFQ&SFRFQ, and Dielectric-Wall Accelerator (DWA) projects (respectively, 50 mA of D(+), 10 mA of O(+), 10 mA of He(+), and 50 mA of H(+)). In order to improve performance of these ion sources, it is necessary to better understand the principal factors that influence the plasma density and the atomic ion fraction. Theoretical analysis about microwave transmission and cut-off inside the discharge chamber were carried out to study the influence of the discharge chamber diameters. As a consequence, experimental studies on plasma density and ion fraction with different discharge chamber sizes have been carried out. Due to the difficulties in measuring plasma density inside the discharge chamber, the output beam current was measured to reflect the plasma density. Experimental results show that the plasma density increases to the maximum and then decreases significantly as the diameter changed from 64 mm to 30 mm, and the atomic ion fraction has the same tendency. The maximum beam intensity was obtained with the diameter of 35 mm, but the maximum atomic ion fraction with a diameter of 40 mm. The experimental results are basically accordant with the theoretical calculation. Details are presented in this paper.
Yalcin, Ozlem; Jani, Vivek P; Johnson, Paul C; Cabrales, Pedro
2018-01-01
The endothelial glycocalyx is a complex network of glycoproteins, proteoglycans, and glycosaminoglycans; it lines the vascular endothelial cells facing the lumen of blood vessels forming the endothelial glycocalyx layer (EGL). This study aims to investigate the microvascular hemodynamics implications of the EGL by quantifying changes in blood flow hydrodynamics post-enzymatic degradation of the glycocalyx layer. High-speed intravital microscopy videos of small arteries (around 35 μm) of the rat cremaster muscle were recorded at various time points after enzymatic degradation of the EGL. The thickness of the cell free layer (CFL), blood flow velocity profiles, and volumetric flow rates were quantified. Hydrodynamic effects of the presence of the EGL were observed in the differences between the thickness of CFL in microvessels with an intact EGL and glass tubes of similar diameters. Maximal changes in the thickness of CFL were observed 40 min post-enzymatic degradation of the EGL. Analysis of the frequency distribution of the thickness of CFL allows for estimation of the thickness of the endothelial surface layer (ESL), the plasma layer, and the glycocalyx. Peak flow, maximum velocity, and mean velocity were found to statistically increase by 24, 27, and 25%, respectively, after enzymatic degradation of the glycocalyx. The change in peak-to-peak maximum velocity and mean velocity were found to statistically increase by 39 and 32%, respectively, after 40 min post-enzymatic degradation of the EGL. The bluntness of blood flow velocity profiles was found to be reduced post-degradation of the EGL, as the exclusion volume occupied by the EGL increased the effective volume impermeable to RBCs in microvessels. This study presents the effects of the EGL on microvascular hemodynamics. Enzymatic degradation of the EGL resulted in a decrease in the thickness of CFL, an increase in blood velocity, blood flow, and decrease of the bluntness of the blood flow velocity profile in small arterioles. In summary, the EGL functions as a molecular sieve to solute transport and as a lubrication layer to protect the endothelium from red blood cell (RBC) motion near the vessel wall, determining wall shear stress.
Yoo, Jung-Hwa; Yim, Sung-Vin
2018-01-01
Background Bojungikki-tang (BJIKT) is a widely used traditional herbal formula in China, Japan, and Korea. There have been reports that several herbs among BJIKT have interactions with antiplatelet drugs, such as aspirin. This study aimed to assess whether BJIKT interacts with aspirin in terms of pharmacokinetics (PK) and pharmacodynamics (PD) in healthy subjects and ischemic stroke patients. Methods The phase I interaction trial was a randomized, open-label, crossover study of 10 healthy male subjects, and the phase III interaction trial was a randomized, placebo-controlled, parallel study of 43 ischemic stroke patients. Each participant randomly received aspirin + BJIKT or aspirin + placebo. For PK analysis, plasma acetyl salicylic acid (ASA) and salicylic acid (SA) were evaluated, and, for PD analysis, platelet aggregation and plasma thromboxane B2 (TxB2) were measured. Results In the PK parameters, mean area under curve, maximum concertation, and peak concentration time of ASA and SA were not different between two groups in healthy subjects and ischemic stroke patients. In the PD profiles, TxB2 concentrations and platelet aggregation were not affected by coadministration of BJIKT in healthy subjects and ischemic stroke patients. Conclusions These results suggest that coadministration of BJIKT with aspirin may not result in herb-drug interaction. PMID:29599812
Utilization of dietary urea in rainbow trout.
Kaushik, S J; Dabrowski, K R; Dabrowska, H; Olah, E; Luquet, P
1983-01-01
Experiments were conducted to examine the potential utilization of dietary urea by rainbow trout. A control diet and two diets supplemented with 1 and 3% of urea were fed to fish. Postprandial levels of urea and ammonia in blood plasma, and postprandial excretion of these metabolites were followed during 24 h. Apparent digestibility of urea in rainbow trout was very high (greater than 98%). Maximum values of urea levels in plasma were reached 6 h (32.3 +/- 10.2 micrograms/ml) after a meal in the control fish and respectively 6 h (83.4 +/- 18.4 micrograms/ml) and 8 h (250.3 +/- 96.1 micrograms/ml) after a meal in trout fed 1 and 3% urea diets. Peaks of urea excretion rates appeared 7-9 h after meal, coinciding with the highest circulating urea concentration. Total daily urea excretion amounted to 5.53, 10.43 and 33.80 mg urea N/100 mg N intake in trout fed the control, 1 and 3% urea diets, respectively. It is concluded that the dietary urea is readily absorbed in the digestive tract of trout but is totally excreted thus leading to no beneficial effect on nitrogen balance. This excretion of urea also takes place passively without any increase in energy demands.
Lee, Soo-Han; Kim, Seung-Hyun; Noh, Yook-Hwan; Choi, Byung-Moon; Noh, Gyu-Jeong; Park, Woo-Dae; Kim, Eun-Jung; Cho, Ik-Hyun; Bae, Chun-Sik
2016-02-01
Memantine is a non-competitive N-methyl-D-aspartate (NMDA) receptor antagonist used to treat Alzheimer's disease. We investigated memantine pharmacokinetics after oral, IV and patch administration in rats, and compared memantine pharmacokinetics after multiple- or single-dose oral and transdermal administration. Venous blood was collected at preset intervals in single- and multiple-dose studies. Non-compartmental pharmacokinetics was analysed for all formulations. The oral, IV and patch memantine doses were 10 mg/kg, 2 mg/kg and 8.21 ± 0.89 mg/kg, respectively. The maximum plasma concentration was lower and the half-life longer after patch administration than oral and IV administration. Memantine bioavailability was 41 and 63% for oral and patch administration, respectively. Steady state was achieved around 24 hr for oral and patch administration. The mean AUC increased after oral or patch administration from single to multiple dose. The memantine patch formulation displayed a longer duration of action and lower peak plasma concentration. However, drug exposure was similar to the oral formulation at each dose. Additionally, the memantine patch formulation displayed a smaller interindividual variability and lower accumulation than the oral formulation. © 2015 Nordic Association for the Publication of BCPT (former Nordic Pharmacological Society).
NASA Astrophysics Data System (ADS)
Zhang, Jiangbo; Li, Xingwen; Hang, Yuhua; Yang, Weihong
2018-06-01
In order to study the characteristics of electrothermal plasma interaction with energetic materials, especially the ignition ability, a novel model considering polyethylene and copper ablation is developed, and an ignition experiment system is set up. The parameters of the plasma and the surface conditions of the energetic materials are measured in the testing. The results show the measured first peak pressure to be ~2.2 MPa, the second peak pressure to be ~3.9 MPa, and the visible flame velocity to be ~2000 m s‑1. Circular pits of the order of microns and nanometers in size are observed on the surface of the energetic materials. Further, the parameters of the plasma, including static pressure, total pressure, density, temperature, velocity, copper concentration and PE concentration, are calculated and analyzed by the established model, under discharge currents of 9 kA. The simulation is similar to those of experimental results. A shock wave is observed in the experiment and is presented in the calculations; it plays an important role in the performance of the plasma in the nozzle region, where the parameters of the plasma variation trends are very complex. With the aim of obtaining the overall performance of the plasma, the coupling characteristics of multiple parameters must be taken into account, in accordance with the developed electrothermal plasma model.
Analysis of radiofrequency discharges in plasma
Kumar, D.; McGlynn, S.P.
1992-08-04
Separation of laser optogalvanic signals in plasma into two components: (1) an ionization rate change component, and (2) a photoacoustic mediated component. This separation of components may be performed even when the two components overlap in time, by measuring time-resolved laser optogalvanic signals in an rf discharge plasma as the rf frequency is varied near the electrical resonance peak of the plasma and associated driving/detecting circuits. A novel spectrometer may be constructed to make these measurements. Such a spectrometer would be useful in better understanding and controlling such processes as plasma etching and plasma deposition. 15 figs.
Method and apparatus for electrospark deposition
Bailey, Jeffrey A.; Johnson, Roger N.; Park, Walter R.; Munley, John T.
2004-12-28
A method and apparatus for controlling electrospark deposition (ESD) comprises using electrical variable waveforms from the ESD process as a feedback parameter. The method comprises measuring a plurality of peak amplitudes from a series of electrical energy pulses delivered to an electrode tip. The maximum peak value from among the plurality of peak amplitudes correlates to the contact force between the electrode tip and a workpiece. The method further comprises comparing the maximum peak value to a set point to determine an offset and optimizing the contact force according to the value of the offset. The apparatus comprises an electrode tip connected to an electrical energy wave generator and an electrical signal sensor, which connects to a high-speed data acquisition card. An actuator provides relative motion between the electrode tip and a workpiece by receiving a feedback drive signal from a processor that is operably connected to the actuator and the high-speed data acquisition card.
Kinetics and Chemistry of Ionization Wave Discharges Propagating Over Dielectric Surfaces
NASA Astrophysics Data System (ADS)
Petrishchev, Vitaly
Experimental studies of near-surface ionization wave electric discharges generated by high peak voltage (20-30 kV), nanosecond duration pulses (full width at half-maximum 50-100 ns) of positive and negative polarity and propagating over dielectric surfaces have been performed. A novel way to sustain diffuse, reproducible, ns pulse surface plasmas at a liquid-vapor interface is demonstrated at buffer gas pressures ranging from 10 to 200 Torr. Generation of surface ionization waves well reproduced shot-to-shot and sustaining diffuse near-surface plasmas is one of the principal advantages of the use of ns pulse discharge waveforms. This makes possible characterization of these plasmas in repetitively pulsed experiments. Numerous applications of these plasmas include low-temperature plasma assisted combustion, plasma fuel reforming, plasma flow control, plasma materials processing, agriculture, biology, and medicine. The objectives of the present work are (i) to demonstrate that surface ionization wave discharge plasmas sustained at a liquid-vapor interface can be used as an experimental platform for studies of near-surface plasma chemical reaction kinetics, at the conditions when the interface acts as a high-yield source of radical species, and (ii) to obtain quantitative insight into dynamics, kinetics and chemistry of surface ionization wave discharges and provide experimental data for validation of kinetic models, to assess their predictive capability. Generation of the initial radical pool may trigger a number of plasma chemical processes leading to formation of a variety of stable product species, depending on the initial composition of the liquid and the buffer gas flow. One of the products formed and detected during surface plasma / liquid water interaction is hydroxyl radical, which is closely relevant to applications of plasmas for biology and medicine. The present work includes detailed studies of surface ionization wave discharges sustained in different buffer gases over solid and liquid dielectric surfaces, such as quartz, distilled water, saline solution, and alcohols, over a wide range of pressures. Specific experiments include: measurements of ionization wave speed; plasma emission imaging using a ns gate camera; detection of surface discharge plasma chemistry products using Fourier transform infrared absorption spectroscopy; surface charge dynamics on short (ns) and long (hundreds of mus) time scales; time-resolved electron density and electron temperature measurements in a ns pulse surface discharge in helium by Thomson scattering; spatially-resolved absolute OH and H atom concentration measurements in ns pulse discharges over distilled water by single-photon and two-photon Laser Induced Fluorescence; and schlieren imaging of perturbations generated by a ns pulse dielectric barrier discharge in a surface plasma actuator in quiescent atmospheric pressure air.
Production and study of high-beta plasma confined by a superconducting dipole magneta)
NASA Astrophysics Data System (ADS)
Garnier, D. T.; Hansen, A.; Mauel, M. E.; Ortiz, E.; Boxer, A. C.; Ellsworth, J.; Karim, I.; Kesner, J.; Mahar, S.; Roach, A.
2006-05-01
The Levitated Dipole Experiment (LDX) [J. Kesner et al., in Fusion Energy 1998, 1165 (1999)] is a new research facility that is exploring the confinement and stability of plasma created within the dipole field produced by a strong superconducting magnet. Unlike other configurations in which stability depends on curvature and magnetic shear, magnetohydrodynamic stability of a dipole derives from plasma compressibility. Theoretically, the dipole magnetic geometry can stabilize a centrally peaked plasma pressure that exceeds the local magnetic pressure (β>1), and the absence of magnetic shear allows particle and energy confinement to decouple. In initial experiments, long-pulse, quasi-steady-state microwave discharges lasting more than 10s have been produced that are consistent with equilibria having peak beta values of 20%. Detailed measurements have been made of discharge evolution, plasma dynamics and instability, and the roles of gas fueling, microwave power deposition profiles, and plasma boundary shape. In these initial experiments, the high-field superconducting floating coil was supported by three thin supports. The plasma is created by multifrequency electron cyclotron resonance heating at 2.45 and 6.4GHz, and a population of energetic electrons, with mean energies above 50keV, dominates the plasma pressure. Creation of high-pressure, high-beta plasma is possible only when intense hot electron interchange instabilities are stabilized by sufficiently high background plasma density. A dramatic transition from a low-density, low-beta regime to a more quiescent, high-beta regime is observed when the plasma fueling rate and confinement time become sufficiently large.
Yeung, S S; Ng, G Y
2000-06-01
Manual lifting is a frequent cause of back injury, and there is no evidence as to which training mode can provide the best training effect for lifting performance and muscle force. The purpose of this study was to examine the effects of a squat lift training and a free weight muscle training program on the maximum lifting load and isokinetic peak torque in subjects without known neuromuscular or musculoskeletal impairments. Thirty-six adults (20 male, 16 female) without known neuromuscular or musculoskeletal impairments participated. The subjects' mean age was 21.25 years (SD=1.16, range=20-24). Subjects were divided into 3 groups. Subjects in group 1 (n=12) performed squat lift training. Subjects in group 2 (n=12) participated in free weight resistance training of their shoulder abductors, elbow flexors, knee extensors and trunk extensors. Subjects in group 3 (n=12) served as controls. The maximum lifting load and isokinetic peak torques of the trunk extensors, knee extensors, elbow flexors, and shoulder abductors of each subject were measured before and after the study. Training was conducted on alternate days for 4 weeks, with an initial load of 80% of each subject's maximum capacity and with the load increased by 5% weekly. All groups were comparable for all measured variables before the study. After 4 weeks, subjects in groups 1 and 2 demonstrated more improvement in maximum lifting load and isokinetic peak torque of the back extensors compared with the subjects in group 3, but the 2 training groups were not different. The findings demonstrate that both squat lift and free weight resistance training are equally effective in improving the lifting load and isokinetic back extension performance of individuals without impairments.
Understanding the ion distributions near the boundaries of reconnection outflow region
NASA Astrophysics Data System (ADS)
Zhou, X.; Pan, D.; Angelopoulos, V.; Runov, A.; Zong, Q.; Pu, Z.
2016-12-01
An interesting signature observed shortly after the onset of magnetotail reconnection is the gradual appearance of a local peak of ion phase space density (PSD) in the duskward and downstream direction separated from the colder, nearly-isotropic ion population. Such characteristic ion distributions, well reproduced by a particle-tracing Liouville simulation, are found to appear only near the off-equatorial boundaries of the reconnection outflow region. Further analysis on ion trajectories suggests that the ions at the local peak and at the neighboring PSD cleft both belong to the outflowing population; they both meander across the neutral sheet to exhibit duskward velocities near the off-equatorial boundaries of their trajectories. The difference between them is that the local peak originates from ions previously constituting the pre-onset plasma sheet, whereas the cleft corresponds to the inflowing lobe ions before they are repelled in the downstream direction. As reconnection proceeds, the local PSD peak attenuates and then disappears, which indicates the eventual depletion of thermal ions in the pre-onset plasma sheet.
Impact of temperature-velocity distribution on fusion neutron peak shape
NASA Astrophysics Data System (ADS)
Munro, David
2016-10-01
Doppler broadening of the 14 MeV DT and 2.45 MeV DD fusion neutron lines has long been our best measure of temperature in a burning plasma. At the National Ignition Facility yields are high enough and our neutron spectrometers accurate enough that we see finer details of the peak shape. For example, we can measure the shift of the peak due to bulk motion of the plasma, and we see indications of non-thermal broadening, skew, and kurtosis of the peak caused by the variations of temperature and fluid velocity during burn. We can also distinguish spectral differences among several lines of sight. This talk will review the theory of fusion neutron line shape, show examples of non-Gaussian line shapes and directional variations in NIF data, and describe detailed spectral shapes we see in radhydro implosion simulations. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.
Thiele, Thomas; Hron, Gregor; Kellner, Sarah; Wasner, Christina; Westphal, Antje; Warkentin, Theodore E; Greinacher, Andreas; Selleng, Kathleen
2016-01-01
Methylene blue pathogen inactivation and storage of thawed plasma both lead to changes in the activity of several clotting factors. We investigated how this translates into a global loss of thrombin generation potential and alterations in the protein C pathway. Fifty apheresis plasma samples were thawed and each divided into three subunits. One subunit was stored for 7 days at 4 °C, one was stored for 7 days at 22 °C and one was stored at 4 °C after methylene blue/light treatment. Thrombin generation parameters, ProC(®)Global-NR, prothrombin time and activated partial thromboplastin time were assessed on days 0 and 7. The velocity of thrombin generation increased significantly after methylene blue treatment (increased thrombin generation rate; time to peak decreased) and decreased after storage (decreased thrombin generation rate and peak thrombin; increased lag time and time to peak). The endogenous thrombin generation potential remained stable after methylene blue treatment and storage at 4 °C. Methylene blue treatment and 7 days of storage at 4 °C activated the protein C pathway, whereas storage at room temperature and storage after methylene blue treatment decreased the functional capacity of the protein C pathway. Prothrombin time and activated partial thromboplastin time showed only modest alterations. The global clotting capacity of thawed plasma is maintained at 4 °C for 7 days and directly after methylene blue treatment of thawed plasma. Thrombin generation and ProC(®)Global are useful tools for investigating the impact of pathogen inactivation and storage on the clotting capacity of therapeutic plasma preparations.
Newcombe, David A L; Somogyi, Andrew A; Bochner, Felix; White, Jason M
2017-06-01
Tolerance to the psychomotor impairing effects of opioid drugs is expected to develop with repeated dosing, but may be incomplete. The relationship between plasma opioid concentration and psychomotor function in opioid-dependent patients was examined to determine whether impairment was more likely at the time of highest plasma drug concentration. Sixteen patients participating in a cross-over trial comparing methadone and LAAM completed a tracking task (OSPAT) 11 times over the dosing-interval for methadone (24-hrs) and LAAM (48-hrs). Venous blood was collected for the quantification of plasma (R)-(-)-methadone, LAAM, and nor-LAAM concentrations. The Digit Symbol Substitution Test (DSST) and Trail-Making Test were administered at the time of peak plasma concentration. Ten healthy controls (HCs) also participated. OSPAT scores (obtained for 15 patients) fluctuated significantly across the dosing-interval for both drugs and were lower in patients than HCs at the times of peak concentrations of (R)-(-)-methadone (1 hr: (mean difference; 95% CI) (2.13; 0.18-4.08); 2 hrs: (2.38; 0.48-4.28) postdosing) and LAAM (2 hrs: (1.81; 0.09-3.53), and 4 hrs (1.90: 0.9-3.71) postdosing). Within-participant analysis of the peak-change from baseline for OSPAT scores found that 10 of the 15 patients could be categorized as impaired on methadone and 9 on LAAM. No HCs were impaired. Patients performed worse on the DSST and Trails-A than HCs, but not on Trails-B. Results suggest that some patients receiving opioids long term may exhibit impairment at the time of highest plasma drug concentration. These patients should be made aware that their ability to undertake complex tasks may be affected. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Shock heating of the solar wind plasma
NASA Technical Reports Server (NTRS)
Whang, Y. C.; Liu, Shaoliang; Burlaga, L. F.
1990-01-01
The role played by shocks in heating solar-wind plasma is investigated using data on 413 shocks which were identified from the plasma and magnetic-field data collected between 1973 and 1982 by Pioneer and Voyager spacecraft. It is found that the average shock strength increased with the heliocentric distance outside 1 AU, reaching a maximum near 5 AU, after which the shock strength decreased with the distance; the entropy of the solar wind protons also reached a maximum at 5 AU. An MHD simulation model in which shock heating is the only heating mechanism available was used to calculate the entropy changes for the November 1977 event. The calculated entropy agreed well with the value calculated from observational data, suggesting that shocks are chiefly responsible for heating solar wind plasma between 1 and 15 AU.
[Caloric value and energy allocation of Chloris virgata in northeast grassland].
Guo, J; Wang, R; Wang, W
2001-06-01
The rules of seasonal changes in caloric values of individual plant, stem, and leaves of Chloris virgata were similar, which had two peak values from early July to early August, and then decreased gradually. Those of inflorescence assumed U shape, and had two peak values in early August and middle September, respectively. The seasonal changes in caloric values of dead standing were irregular, and the maximum value was appeared in early August. The seasonal changes in existent energy value of the aboveground parts in Chloris virgata population presented double peak curve. The two peak values were appeared in early August and early September respectively, and the maximum value was 7381.27 kJ.m-2 in early September. The energy allocation in different seasons was leaf > stem in early July, stem > leaf > dead standing in middle July, stem > leaf > inflorescence > dead standing in August, stem > inflorescence > leaf > dead standing in early September, and stem > inflorescence > dead standing > leaf in middle September. The vertical structure of energy in the aboveground parts was that the energy value gradually increased from the earth's surface to 20 cm high, and then decreased. The maximum value, which accounted for 25.75% of energy in the aboveground parts, was appeared in the layer of 10-20 cm high. In the underground parts, the energy value progressively decreased with the increase of depth, and the maximum value, which accounted for 74.21% of energy in the underground parts, was appeared in the layer of 0-10 cm depth.
NASA Astrophysics Data System (ADS)
Lyons, B. C.; Ferraro, N. M.; Paz-Soldan, C.; Nazikian, R.; Wingen, A.
2017-04-01
In order to understand the effect of rotation on the response of a plasma to three-dimensional magnetic perturbations, we perform a systematic scan of the zero-crossing of the rotation profile in a DIII-D ITER-similar shape equilibrium using linear, time-independent modeling with the M3D-C1 extended magnetohydrodynamics code. We confirm that the local resonant magnetic field generally increases as the rotation decreases at a rational surface. Multiple peaks in the resonant field are observed near rational surfaces, however, and the maximum resonant field does not always correspond to zero rotation at the surface. Furthermore, we show that non-resonant current can be driven at zero-crossings not aligned with rational surfaces if there is sufficient shear in the rotation profile there, leading to amplification of near-resonant Fourier harmonics of the perturbed magnetic field and a decrease in the far-off-resonant harmonics. The quasilinear electromagnetic torque induced by this non-resonant plasma response provides drive to flatten the rotation, possibly allowing for increased transport in the pedestal by the destabilization of turbulent modes. In addition, this torque acts to drive the rotation zero-crossing to dynamically stable points near rational surfaces, which would allow for increased resonant penetration. By one or both of these mechanisms, this torque may play an important role in bifurcations into suppression of edge-localized modes. Finally, we discuss how these changes to the plasma response could be detected by tokamak diagnostics. In particular, we show that the changes to the resonant field discussed here have a significant impact on the external perturbed magnetic field, which should be observable by magnetic sensors on the high-field side of tokamaks but not on the low-field side. In addition, TRIP3D-MAFOT simulations show that none of the changes to the plasma response described here substantially affects the divertor footprint structure.
Lyons, Brendan C.; Ferraro, Nathaniel M.; Paz-Soldan, Carlos A.; ...
2017-02-14
In order to understand the effect of rotation on the plasma's response to three-dimensional magnetic perturbations, we perform a systematic scan of the zero-crossing of the rotation profile in a DIII-D ITER-similar shape equilibrium using linear, time-independent modeling with the M3D-C1 extended magnetohydrodynamics code. We confirm that the local resonant magnetic field generally increases as the rotation decreases at a rational surface. Multiple peaks in the resonant field are observed near rational surfaces, however, and the maximum resonant field does not always correspond to zero rotation at the surface. Furthermore, we show that non-resonant current can be driven at zero-more » crossings not aligned with rational surfaces if there is sufficient shear in the rotation profile there, leading to an amplification of near-resonant Fourier harmonics of the perturbed magnetic field and a decrease in the far-off -resonant harmonics. The quasilinear electromagnetic torque induced by this non-resonant plasma response provides drive to flatten the rotation, possibly allowing for increased transport in the pedestal by the destabilization of turbulent modes. In addition, this torque acts to drive the rotation zero-crossing to dynamically stable points near rational surfaces, which would allow for increased resonant penetration. By one or both of these mechanisms, this torque may play an important role in bifurcations into ELM suppression. Finally, we discuss how these changes to the plasma response could be detected by tokamak diagnostics. In particular, we show that the changes to the resonant field discussed here have a significant impact on the external perturbed magnetic field, which should be observable by magnetic sensors on the high-field side of tokamaks, but not on the low-field side. In addition, TRIP3D-MAFOT simulations show that none of the changes to the plasma response described here substantially affects the divertor footprint structure.« less
Chandorkar, Gurudatt; Zhan, Qiao; Donovan, Julie; Rege, Shruta; Patino, Hernando
2017-03-28
Surotomycin, a novel, orally administered, cyclic, lipopeptide antibacterial in development for the treatment of Clostridium difficile-associated diarrhea, has demonstrated minimal intestinal absorption in animal models. Safety, tolerability, and plasma pharmacokinetics of single and multiple ascending oral doses (SAD/MAD) of surotomycin in healthy volunteers were characterized in two randomized, double-blind, placebo-controlled, phase 1 studies. Participants were sequentially enrolled into one of four SAD (500, 1000, 2000, 4000 mg surotomycin) or three MAD (250, 500, 1000 mg surotomycin twice/day for 14 days) cohorts. Ten subjects were randomized 4:1 into each cohort to receive surotomycin or placebo. Surotomycin plasma concentrations rose as dose increased (maximum plasma concentration [C max ]: 10.5, 21.5, 66.6, and 86.7 ng/mL). Systemic levels were generally low, with peak median surotomycin plasma concentrations observed 6-12 h after the first dose. In the MAD study, surotomycin plasma concentrations were higher on day 14 (C max : 25.5, 37.6, and 93.5 ng/mL) than on day 1 (C max : 6.8, 11.0, and 21.1 ng/mL for increasing doses), indicating accumulation. In the SAD study, <0.01% of the administered dose was recovered in urine. Mean surotomycin stool concentration from the 1000 mg MAD cohort was 6394 μg/g on day 5. Both cohorts were well tolerated with all adverse events reported as mild to moderate. Both SAD and MAD studies of surotomycin demonstrated minimal systemic exposure, with feces the primary route of elimination following oral administration; consistent with observations with similar compounds, such as fidaxomicin. Results of these phase 1 studies support the continued clinical development of surotomycin for the treatment of Clostridium difficile-associated diarrhea. NCT02835118 and NCT02835105 . Retrospectively registered, July 13 2016.
Lin, Y M; Chen, C N; Yoshinaga, T; Tsai, S C; Shen, I D; Lee, T H
2006-03-01
Changes in expression of gill Na+/K+ -ATPase (NKA) on a short-term (96 h) time-course following hyposmotic shock (direct transfer to fresh water) of the euryhaline, marine milkfish were studied on gene, protein, and cell levels in this paper. Plasma osmolality and [Na+] responded with rapid declines in 3 h post-transfer yet, thereafter, remained constant. Plasma [Cl-] gradually fell to a significantly lower level at 6 h post-transfer. Gills responded to hyposmotic shock by a dual phase enhancement of NKA activity and protein abundance; (a) Before 24 h: NKA activity increased as early as 3 h and reached a maximum level from 6 to 12 h post-transfer coincided with the sustained lower levels of plasma osmolality, [Na+], and [Cl-] since 3 h post-transfer. This was followed by a gradual rise in alpha-subunit protein levels that peaked at 12 h post-transfer. Meanwhile, alpha-mRNA of NKA did no show significant change. (b) After 24 h: NKA activity as well as the amounts of alpha-subunit mRNA and protein increased significantly. Direct freshwater transfer induced a prompt and significant decrease of NKA immunoreactive (NKIR) cell abundance in filaments before 24 h, followed by a significant increase after 24 h due to their development in filaments and lamellae. Increased number of NKIR cells after 24 h of hyposmotic shock may occur in conjunction with rise of NKA activity as well as alpha-subunit mRNA and protein abundance. In conclusion, milkfish is able to avoid an excessive drop in plasma ions immediately upon hyposmotic shock and maintain plasma ions on a marginal lower level in fresh water. Notably, the initial increase in NKA activity (adjustive phase; 3-12 h) and delayed increase in NKA mRNA and protein abundance (regulatory phase; 48-96 h) indicate the importance of a higher level of the gill enzyme in milkfish upon hyposmotic shock.
Prognostic value of metabolic metrics extracted from baseline PET images in NSCLC
Carvalho, Sara; Leijenaar, Ralph T.H.; Velazquez, Emmanuel Rios; Oberije, Cary; Parmar, Chintan; van Elmpt, Wouter; Reymen, Bart; Troost, Esther G.C.; Oellers, Michel; Dekker, Andre; Gillies, Robert; Aerts, Hugo J.W.L.; Lambin, Philippe
2015-01-01
Background Maximum, mean and peak SUV of primary tumor at baseline FDG-PET scans, have often been found predictive for overall survival in non-small cell lung cancer (NSCLC) patients. In this study we further investigated the prognostic power of advanced metabolic metrics derived from Intensity-Volume Histograms (IVH) extracted from PET imaging. Methods A cohort of 220 NSCLC patients (mean age, 66.6 years; 149 men, 71 women), stages I-IIIB, treated with radiotherapy with curative intent were included (NCT00522639). Each patient underwent standardized pre-treatment CT-PET imaging. Primary GTV was delineated by an experienced radiation oncologist on CT-PET images. Common PET descriptors such as maximum, mean and peak SUV, and metabolic tumor volume (MTV) were quantified. Advanced descriptors of metabolic activity were quantified by IVH. These comprised 5 groups of features: Absolute and Relative Volume above Relative Intensity threshold (AVRI and RVRI), Absolute and Relative Volume above Absolute Intensity threshold (AVAI and RVAI), and Absolute Intensity above Relative Volume threshold (AIRV). MTV was derived from the IVH curves for volumes with SUV above 2.5, 3 and 4, and of 40% and 50% maximum SUV. Univariable analysis using Cox Proportional Hazard Regression was performed for overall survival assessment. Results Relative volume above higher SUV (80 %) was an independent predictor of OS (p = 0.05). None of the possible surrogates for MTV based on volumes above SUV of 3, 40% and 50% of maximum SUV showed significant associations with OS (p (AVAI3) = 0.10, p (AVAI4) = 0.22, p (AVRI40%) = 0.15, p (AVRI50%) = 0.17). Maximum and peak SUV (r = 0.99) revealed no prognostic value for OS (p (maximum SUV) = 0.20, p (peak SUV) = 0.22). Conclusions New methods using more advanced imaging features extracted from PET were analyzed. Best prognostic value for OS of NSCLC patients was found for relative portions of the tumor above higher uptakes (80% SUV). PMID:24047338
NASA Astrophysics Data System (ADS)
Nicolaou, G.; Yamauchi, M.; Wieser, M.; Nilsson, H.; Behar, E.; Stenberg Wieser, G.
2016-12-01
The Ion Composition Analyzer (ICA) on board ROSETTA is a part of the Rosetta Plasma Consortium (RPC). It is designed to measure the 3-D velocity distribution function of the plasma ions in the environment of the comet 67P/Churyumov-Gerasimenko. Besides the solar wind plasma ions, ICA detected the heavy ions of cometary origin at both low energy (< 100 eV) and at the keV range. So far, ICA distinguished ions of water origin but in principle it should be able to detect CO2+. However, we have not yet succeeded to separate CO2+ ions from O+ or H2O+ ion, mainly due to non-uniform sensitivity and noise level at different mass-channels//azimuthal-sectors, and high cross talk. In May 2016, when ROSETTA was relatively close to the comet (between 6 and 20 km), we observe a second plasma ion population in a higher energy per charge range ( 60-200 eV/q) than the water group ions at 30- 50eV/q. To examine whether this secondary population is still the water group or other ions, such as CO2+, we cleaned the raw data by correcting the non-uniform sensitivity assuming that the noise level should be uniform over different channels. After such a simple cleaning we already found that the mass peak at low energy and that for higher-energy are occasionally similar but in some cases are quite different. Furthermore, we investigate few cases where the low-energy mass peak seems to consist of different Gaussian slopes, indicating that this peak could be composed of two mass peaks. In this presentation we show our techniques we follow to process the data, and we show how we identify the secondary ion component from the May 2016 data.
Hoefle, Anja S; Bangert, Adina M; Stamfort, Adelmar; Gedrich, Kurt; Rist, Manuela J; Lee, Yu-Mi; Skurk, Thomas; Daniel, Hannelore
2015-03-01
Casein is considered a slowly digestible protein compared with whey protein, and this may cause differences in hormone responses and the kinetics of delivering amino acids into the circulation. We investigated whether postprandial plasma hormone and metabolite responses were different when bovine casein or whey protein was co-administered with carbohydrates in healthy and prediabetic adults. White healthy male adults (n = 15) and white, well-defined male and female prediabetic adults (n = 15) received test drinks randomly on 3 different occasions at least 2 d apart which contained 50 g of maltodextrin19 (MD19) alone or in combination with 50 g of whey protein isolate (WPI) or 50 g of sodium caseinate (SC). Blood samples were collected over a 240-min time period and were analyzed for hormone profiles and defined metabolites. No evidence was found that gastric emptying was different between the 2 protein drinks. Both proteins increased peak plasma insulin concentrations in prediabetic persons by 96% compared with MD19 (each, P < 0.05), which was accompanied by a reduction of peak venous blood glucose by 21% (each, P < 0.0001) without a difference between the 2 proteins. Peak plasma glucagon concentrations increased by 101% in both groups after the protein drinks (P < 0.05). The WPI drink also increased peak plasma glucose-dependent insulinotropic polypeptide concentrations in healthy volunteers by 56% (P < 0.01). Differences in plasma metabolite concentrations in volunteers could be attributed exclusively to the differences in the amino acid composition of the 2 proteins ingested. The WPI and the SC drinks similarly reduced postprandial glucose excursions when ingested with carbohydrates in healthy and prediabetic volunteers. Under our experimental conditions, however, no evidence was found that gastrointestinal processing of the 2 protein varieties differed substantially. This trial was registered at clinicaltrials.gov as DRKS00005682. © 2015 American Society for Nutrition.
Limitations to maximum running speed on flat curves.
Chang, Young-Hui; Kram, Rodger
2007-03-01
Why is maximal running speed reduced on curved paths? The leading explanation proposes that an increase in lateral ground reaction force necessitates a decrease in peak vertical ground reaction force, assuming that maximum leg extension force is the limiting factor. Yet, no studies have directly measured these forces or tested this critical assumption. We measured maximum sprint velocities and ground reaction forces for five male humans sprinting along a straight track and compared them to sprints along circular tracks of 1, 2, 3, 4 and 6 m radii. Circular track sprint trials were performed either with or without a tether that applied centripetal force to the center of mass. Sprinters generated significantly smaller peak resultant ground reaction forces during normal curve sprinting compared to straight sprinting. This provides direct evidence against the idea that maximum leg extension force is always achieved and is the limiting factor. Use of the tether increased sprint speed, but not to expected values. During curve sprinting, the inside leg consistently generated smaller peak forces compared to the outside leg. Several competing biomechanical constraints placed on the stance leg during curve sprinting likely make the inside leg particularly ineffective at generating the ground reaction forces necessary to attain maximum velocities comparable to straight path sprinting. The ability of quadrupeds to redistribute function across multiple stance legs and decouple these multiple constraints may provide a distinct advantage for turning performance.
Phonons in Confinement and the Boson Peak Using Nuclear Inelastic Absorption
NASA Astrophysics Data System (ADS)
Asthalter, T.; Bauer, M.; van Bürck, U.; Sergueev, I.; Franz, H.; Chumakov, A. I.
2002-12-01
We have applied nuclear inelastic absorption (NIA) to the molecular glass former dibutylphthalate/ferrocene, both in bulk and in nanoporous matrices having pore sizes of 50 and 25 Å, respectively. The quantity g(E)/E 2, where g(E) is the vibrational phonon density of states (VDOS) of the resonant nuclei, exhibits a pronounced maximum at low energies. Confinement in pores leads to a suppression of the VDOS below 1.5 meV, independent of the pore size. Also in the scaled heat capacity C(T)/T 3, we observe a decrease of the peak maximum for low temperatures. Our observations are discussed in the light of experimental and theoretical results on nanocrystals and a recent theoretical model for the boson peak.
Is plasma N-BNP a good indicator of the functional reserve of failing hearts? The FRESH-BNP study.
Williams, Simon G; Ng, Leong L; O'Brien, Russell J; Taylor, Steve; Wright, D Jay; Tan, Lip-Bun
2004-12-01
Whether plasma N-terminal brain natriuretic peptide (N-BNP) is useful in the diagnosis of heart failure (HF) depends traditionally on whether it is as good as the putative 'gold-standard', left ventricular ejection fraction (LVEF), in indicating cardiac dysfunction. However, since HF is primarily an impairment of function of the cardiac pump, we explored the relationship between N-BNP and direct and indirect indicators of cardiac pump dysfunction. Eighty-six HF patients (mean age 56 years) with a range of LVEF's (mean 36.9+/-15.2%, range 15-66%) and 10 age-matched healthy controls were recruited into the study and had resting N-BNP measured. Cardiopulmonary exercise testing was performed to assess peak oxygen consumption (Vo(2)). A subgroup of 23 subjects underwent further exercise haemodynamic assessment to evaluate peak cardiac power output (CPO). The CHF group had significantly higher N-BNP (median [interquartile range]) levels (299 [705] fmol/ml) than the control group (7 [51] fmol/ml, P<0.005). Significant correlations between N-BNP and peak Vo(2), and N-BNP and peak CPO were observed (R> or =0.5, P<0.005). Although significant correlation was observed between N-BNP and LVEF (R=0.34, P=0.01), the correlations between LVEF and peak Vo(2) or peak CPO (all R<0.3, P>0.3) were not significant. Multivariate analysis identified plasma N-BNP and NYHA class, but not LVEF, as independent predictors of peak Vo(2). We have found that N-BNP was surprisingly good as a simple indicator of cardiac pump dysfunction. Since heart failure is an inadequacy of function, these results strongly support the notion that N-BNP is a useful blood test in estimating the extent of cardiac pump dysfunction and helpful in establishing positive diagnosis of heart failure.