Sample records for maximum transverse diameter

  1. Foramen arcuale: a rare morphological variation located in atlas vertebrae.

    PubMed

    Cirpan, Sibel; Yonguc, Goksin Nilufer; Edizer, Mete; Mas, Nuket Gocmen; Magden, A Orhan

    2017-08-01

    To investigate the incidence of foramen arcuale in dry atlas vertebrae which may cause clinical problems. Eighty-one dry human cervical vertebrae were examined. The evaluated parameters of two atlas vertebrae including foramen arcuale were as follows: maximum antero-posterior, transverse diameters and areas of the right and left superior articular facets and transverse foramina; maximum antero-posterior diameters, heights, areas and central sagittal thickness of bony arch forming roof of foramen arcuale, respectively. All parameters were measured with caliper in milimeters. Thirteen of eighty-one cervical vertebrae specimens (13/81, 16.05%) were atlas and the two of thirteen atlas vertebrae (2/13, 15.38%) had macroscopically complete foramen arcuale. Each of the two atlas vertebrae was including one foramen arcuale (one on the left and one on the right side). There was a statistically significant difference (p = 0.04) between the mean antero-posterior diameter of superior articular facet located on each side of atlas vertebrae, whereas not (p = 0.51) between mean antero-posterior diameter of transverse foramina. There was not any significant difference between the mean transverse diameters and areas of superior articular facets and transverse foramina located on each side of atlas vertebrae, respectively. Each of the areas of transverse foramina located on the same sides with foramen arcuale in two atlas vertebrae was less than the mean areas of transverse foramina located ipsilateral side with each foramen arcuale in thirteen atlas vertebrae. The present study provides additional information about the incidence and topography of the atlas vertebrae including foramen arcuale.

  2. The transverse diameter of the chest on routine radiographs reliably estimates gestational age and weight in premature infants.

    PubMed

    Dietz, Kelly R; Zhang, Lei; Seidel, Frank G

    2015-08-01

    Prior to digital radiography it was possible for a radiologist to easily estimate the size of a patient on an analog film. Because variable magnification may be applied at the time of processing an image, it is now more difficult to visually estimate an infant's size on the monitor. Since gestational age and weight significantly impact the differential diagnosis of neonatal diseases and determine the expected size of kidneys or appearance of the brain by MRI or US, this information is useful to a pediatric radiologist. Although this information may be present in the electronic medical record, it is frequently not readily available to the pediatric radiologist at the time of image interpretation. To determine if there was a correlation between gestational age and weight of a premature infant with their transverse chest diameter (rib to rib) on admission chest radiographs. This retrospective study was approved by the institutional review board, which waived informed consent. The maximum transverse chest diameter outer rib to outer rib was measured on admission portable chest radiographs of 464 patients admitted to the neonatal intensive care unit (NICU) during the 2010 calendar year. Regression analysis was used to investigate the association between chest diameter and gestational age/birth weight. Quadratic term of chest diameter was used in the regression model. Chest diameter was statistically significantly associated with both gestational age (P < 0.0001) and birth weight (P < 0.0001). An infant's gestational age and birth weight can be reliably estimated by comparing a simple measurement of the transverse chest diameter on digital chest radiograph with the tables and graphs in our study.

  3. An analytical investigation of a conceptual design for the station transverse boom rotary joint structure

    NASA Technical Reports Server (NTRS)

    Lake, M. S.; Bush, H. G.

    1986-01-01

    A study was conducted to define an annular ring, discrete roller assembly concept for the space station transverse boom rotary joint. The concept was analyzed using closed-form and finite element techniques, to size structural members for a range of joint diameters and to determine necessary equivalent stiffnesses for the roller assemblies. Also, a mass study of the system was conducted to determine its practicality, and maximum loads in the joint were identified. To obtain the optimum balance between high stiffness and low structural mass in the design of the rotary joint, it is necessary to maximize the diameter of the annular ring within operational constraints (i.e., shuttle cargo bay size). Further, a rotary joint designed with the largest possible ring diameter will result in minimum operational loads in both the roller assemblies and the transition truss members while also allowing minimum design stiffnesses for the roller assemblies.

  4. Power scaling limits in high power fiber amplifiers due to transverse mode instability, thermal lensing, and fiber mechanical reliability

    NASA Astrophysics Data System (ADS)

    Zervas, Michalis N.

    2018-02-01

    We introduced a simple formula providing the mode-field diameter shrinkage, due to heat load in fiber amplifiers, and used it to compare the traditional thermal-lensing power limit (PTL) to a newly developed transverse-mode instability (TMI) power limit (PTMI), giving a fixed ratio of PTMI/PTL≍0.6, in very good agreement with experiment. Using a failure-in-time analysis we also introduced a new power limiting factor due to mechanical reliability of bent fibers. For diode (tandem) pumping power limits of 28kW (52kW) are predicted. Setting a practical limit of maximum core diameter to 35μm, the limits reduce to 15kW (25kW).

  5. Apparatus and method for classifying fuel pellets for nuclear reactor

    DOEpatents

    Wilks, Robert S.; Sternheim, Eliezer; Breakey, Gerald A.; Sturges, Jr., Robert H.; Taleff, Alexander; Castner, Raymond P.

    1984-01-01

    Control for the operation of a mechanical handling and gauging system for nuclear fuel pellets. The pellets are inspected for diameters, lengths, surface flaws and weights in successive stations. The control includes, a computer for commanding the operation of the system and its electronics and for storing and processing the complex data derived at the required high rate. In measuring the diameter, the computer enables the measurement of a calibration pellet, stores that calibration data and computes and stores diameter-correction factors and their addresses along a pellet. To each diameter measurement a correction factor is applied at the appropriate address. The computer commands verification that all critical parts of the system and control are set for inspection and that each pellet is positioned for inspection. During each cycle of inspection, the measurement operation proceeds normally irrespective of whether or not a pellet is present in each station. If a pellet is not positioned in a station, a measurement is recorded, but the recorded measurement indicates maloperation. In measuring diameter and length a light pattern including successive shadows of slices transverse for diameter or longitudinal for length are projected on a photodiode array. The light pattern is scanned electronically by a train of pulses. The pulses are counted during the scan of the lighted diodes. For evaluation of diameter the maximum diameter count and the number of slices for which the diameter exceeds a predetermined minimum is determined. For acceptance, the maximum must be less than a maximum level and the minimum must exceed a set number. For evaluation of length, the maximum length is determined. For acceptance, the length must be within maximum and minimum limits.

  6. 100 mm diameter rod laser amplifiers made of different Nd:glasses

    NASA Astrophysics Data System (ADS)

    Shaykin, A. A.; Kuzmin, A. A.; Shaikin, I. A.; Potemkin, A. K.; Arbuzov, V. I.; Hu, Lili; Wen, Lei; Khazanov, Е A.

    2018-03-01

    We measured the dependence of the weak signal gain of 100 mm diameter rod amplifiers on pump energy and transverse coordinates for four neodymium glass grades. The highest gain was obtained in N31-05 (China), and the highest radial gain uniformity in KGSS-0180 glass (Russia). The data obtained enable the optimal glass grade to be chosen for each specific problem by finding a compromise between maximum output energy and minimum distortion of beam profile.

  7. Reference range of fetal transverse cerebellar diameter between 18 and 24 weeks of pregnancy in a Brazilian population.

    PubMed

    Araujo Júnior, Edward; Martins, Wellington P; Nardozza, Luciano Marcondes Machado; Pires, Claudio Rodrigues; Filho, Sebastião Marques Zanforlin

    2015-02-01

    To determine a reference range of fetal transverse cerebellar diameter in Brazilian population. This was a retrospective cross-sectional study with 3772 normal singleton pregnancies between 18 and 24 weeks of pregnancy. The transverse cerebellar diameter was measured on the axial plane of the fetal head at the level of the lateral ventricles, including the thalamus, cavum septum pellucidum, and third ventricle. To assess the correlation between transverse cerebellar diameter and gestational age, polynomial equations were calculated, with adjustments by the determination coefficient (R2). The mean of fetal transverse cerebellar diameter ranged from 18.49 ± 1.24 mm at 18 weeks to 25.86 ± 1.66 mm at 24 weeks of pregnancy. We observed a good correlation between transverse cerebellar diameter and gestational age, which was best represented by a linear equation: transverse cerebellar diameter: -6.21 + 1.307*gestational age (R2 = 0.707). We determined a reference range of fetal transverse cerebellar diameter for the second trimester of pregnancy in Brazilian population. © The Author(s) 2014.

  8. Biomechanical comparison of fixation methods in transverse patella fractures.

    PubMed

    Scilaris, T A; Grantham, J L; Prayson, M J; Marshall, M P; Hamilton, J J; Williams, J L

    1998-01-01

    To compare monofilament wire versus braided cable for stabilizing transverse patella fractures using the modified AO tension band technique. A randomized blocked (paired) study comparing two fixation methods. Statistical analysis was performed using a nested repeated measures analysis, followed by Bonferroni post hoc testing. Seven paired embalmed knees (mean age 71.8 years, SD 14.6 years) were dissected, and transverse fractures were simulated. The knees were reduced and randomly fixed by either two parallel 0.062-inch Kirschner wires with a 1.0-millimeter-diameter 316L stainless steel monofilament wire tension loop or two Kirschner wires with a 1.0-millimeter-diameter 316L stainless steel braided cable tension loop. Knees were tested by applying a cyclic load through the suprapatellar tendon between twenty and 300 newtons for thirty cycles. The maximum fracture displacement increased with each cycle of loading for both the braided cable and monofilament wire tension loop configurations (p = 0.0001). The average peak displacement at the thirtieth cycle was 2.25 millimeters for monofilament wire and 0.73 millimeters for the cable. When comparing both methods for all cycles, the braided cable allowed less fracture displacement than did the monofilament wire (p = 0.002), and the rate of increase per cycle of maximum fracture displacement was less for the cable than for the wire (p = 0.0001). In transverse, noncomminuted patella fractures, fixation with two Kirschner wires and a 1.0-millimeter braided cable tension loop was superior to the monofilament wire tension loop. Most importantly, the braided cable afforded more predictable results during cyclic loading.

  9. Cross-correlation-based transverse flow measurements using optical resolution photoacoustic microscopy with a digital micromirror device.

    PubMed

    Liang, Jinyang; Zhou, Yong; Maslov, Konstantin I; Wang, Lihong V

    2013-09-01

    A cross-correlation-based method is proposed to quantitatively measure transverse flow velocity using optical resolution photoacoustic (PA) microscopy enhanced with a digital micromirror device (DMD). The DMD is used to alternately deliver two spatially separated laser beams to the target. Through cross-correlation between the slow-time PA profiles measured from the two beams, the speed and direction of transverse flow are simultaneously derived from the magnitude and sign of the time shift, respectively. Transverse flows in the range of 0.50 to 6.84  mm/s are accurately measured using an aqueous suspension of 10-μm-diameter microspheres, and the root-mean-squared measurement accuracy is quantified to be 0.22  mm/s. The flow measurements are independent of the particle size for flows in the velocity range of 0.55 to 6.49  mm/s, which was demonstrated experimentally using three different sizes of microspheres (diameters: 3, 6, and 10 μm). The measured flow velocity follows an expected parabolic distribution along the depth direction perpendicular to the flow. Both maximum and minimum measurable velocities are investigated for varied distances between the two beams and varied total time for one measurement. This technique shows an accuracy of 0.35  mm/s at 0.3-mm depth in scattering chicken breast, making it promising for measuring flow in biological tissue.

  10. [Ultrasonic measurements of fetal thalamus, caudate nucleus and lenticular nucleus in prenatal diagnosis].

    PubMed

    Yang, Ruiqi; Wang, Fei; Zhang, Jialing; Zhu, Chonglei; Fan, Limei

    2015-05-19

    To establish the reference values of thalamus, caudate nucleus and lenticular nucleus diameters through fetal thalamic transverse section. A total of 265 fetuses at our hospital were randomly selected from November 2012 to August 2014. And the transverse and length diameters of thalamus, caudate nucleus and lenticular nucleus were measured. SPSS 19.0 statistical software was used to calculate the regression curve of fetal diameter changes and gestational weeks of pregnancy. P < 0.05 was considered as having statistical significance. The linear regression equation of fetal thalamic length diameter and gestational week was: Y = 0.051X+0.201, R = 0.876, linear regression equation of thalamic transverse diameter and fetal gestational week was: Y = 0.031X+0.229, R = 0.817, linear regression equation of fetal head of caudate nucleus length diameter and gestational age was: Y = 0.033X+0.101, R = 0.722, linear regression equation of fetal head of caudate nucleus transverse diameter and gestational week was: R = 0.025 - 0.046, R = 0.711, linear regression equation of fetal lentiform nucleus length diameter and gestational week was: Y = 0.046+0.229, R = 0.765, linear regression equation of fetal lentiform nucleus diameter and gestational week was: Y = 0.025 - 0.05, R = 0.772. Ultrasonic measurement of diameter of fetal thalamus caudate nucleus, and lenticular nucleus through thalamic transverse section is simple and convenient. And measurements increase with fetal gestational weeks and there is linear regression relationship between them.

  11. The Role of Duplex Ultrasound In Detecting Graft Thrombosis And Endoleak After Endovascular Aortic Repair For Abdominal Aneurysm.

    PubMed

    Mazzaccaro, Daniela; Farina, Augusto; Petsos, Kostantinos; Nano, Giovanni

    2018-05-19

    to assess the role of DUS in detecting endoleaks (EL) and graft thrombosis (GT) in a cohort of patients submitted to EVAR for elective infrarenal AAA in two centers. Data of all consecutive patients treated in two Operative Unit of Vascular Surgery, from 01/01/2000 to 31/12/2016, were retrospectively collected and evaluated. Follow-up data were analyzed to evaluate survival and device-related complications, both at thirty-day and in the mid-term. The results of CTA and DUS that were performed yearly, with a time interval between the two exams lower than 30 days, were paired in terms of maximum transverse diameters of the aneurysmal sac, identification of EL and of GT. Sensibility (SE), specificity (SP), positive predictive value (PPV), negative predictive value (NPV) and accuracy (ACC) of the DUS were calculated with respect to data of each paired CTA and to data of the real clinical diagnosis of either EL or GT. A Student's t test was performed to compare the aneurysmal sac diameters measured with DUS to those of CTA. "Kappa" coefficient of agreement was also calculated. A P value <0.05 was the level reference for statistical significance. A total of 920 patients (104 female, 11.3%) underwent EVAR for elective infrarenal AAA. Technical success was achieved in 910 cases (98.9%). At 30 days, there were 5 deaths (0.5%), no GT and 3 small type II EL which didn't require any adjunctive procedure. Mean follow-up was 64.8 months (range 1-120.3 months). Survival and freedom from complications were estimated to be 78.4%+1.9% and 48.3%+1.7% respectively at 10 years. Seventy-six more EL and 8 GT were recorded. Considering the CTA as the gold standard, SE, SP, and ACC of DUS in the detection of the EL were 93.2%+5.8%, 98.8%+1.1% and 97.8%, respectively, with a PPV of 94.5%+5.2% and a NPV of 98.3%+1.4%. Considering however the real diagnosis of the EL, SE, SP and ACC of DUS were slightly lower (89.4%+6.9%, 98.5%+1.3% and 96.9%, respectively), as well as PPV and NPV (93.1%+5.8% and 97.7%+1.6% respectively). K coefficient of agreement between the measurements of the sac maximum transverse diameter recorded at DUS and CTA was 0.91, with a little underestimation of the aneurysm diameter at DUS if compared to CTA (mean diameter difference of 2.5 mm, 95% CI: 2.25-2.75mm). DUS has proven to be a reliable exam in identifying all GT and most EL after EVAR, if compared to CTA. A good correlation was also observed between the measurements of the sac maximum transverse diameter recorded at DUS and CTA, with a little underestimation of the aneurysm diameter at DUS if compared to CTA. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Anatomic characteristics of ruptured abdominal aortic aneurysm on conventional CT scans: Implications for rupture risk.

    PubMed

    Fillinger, Mark F; Racusin, Jessica; Baker, Robert K; Cronenwett, Jack L; Teutelink, Arno; Schermerhorn, Marc L; Zwolak, Robert M; Powell, Richard J; Walsh, Daniel B; Rzucidlo, Eva M

    2004-06-01

    The purpose of this study was to analyze anatomic characteristics of patients with ruptured abdominal aortic aneurysms (AAAs), with conventional two-dimensional computed tomography (CT), including comparison with control subjects matched for age, gender, and size. Records were reviewed to identify all CT scans obtained at Dartmouth-Hitchcock Medical Center or referring hospitals before emergency AAA repair performed because of rupture or acute severe pain (RUP group). CT scans obtained before elective AAA repair (ELEC group) were reviewed for age and gender match with patients in the RUP group. More than 40 variables were measured on each CT scan. Aneurysm diameter matching was achieved by consecutively deleting the largest RUP scan and the smallest ELEC scan to prevent bias. CT scans were analyzed for 259 patients with AAAs: 122 RUP and 137 ELEC. Patients were well matched for age, gender, and other demographic variables or risk factors. Maximum AAA diameter was significantly different in comparisons of all patients (RUP, 6.5 +/- 2 cm vs ELEC, 5.6 +/- 1 cm; P <.0001), and mean diameter of ruptured AAAs was 5 mm smaller in female patients (6.1 +/- 2 cm vs 6.6 +/- 2 cm; P =.007). Two hundred patients were matched for diameter, gender, and age (100 from each group; maximum AAA diameter, 6.0 +/- 1 cm vs 6.0 +/- 1 cm). Analysis of diameter-matched AAAs indicated that most variables were statistically similar in the two groups, including infrarenal neck length (17 +/- 1 mm vs 19 +/- 1 mm; P =.3), maximum thrombus thickness (25 +/- 1 mm vs 23 +/- 1 mm, P =.4), and indices of body habitus, such as [(maximum AAA diameter)/(normal suprarenal aorta diameter)] or [(maximum AAA diameter)/(L3 transverse diameter)]. Multivariate analysis controlling for gender indicated that the most significant variables for rupture were aortic tortuosity (odds ratio [OR] 3.3, indicating greater risk with no or mild tortuosity), diameter asymmetry (OR, 3.2 for a 1-cm difference in major-minor axis), and current smoking (OR, 2.7, with the greater risk in current smokers). When matched for age, gender, and diameter, ruptured AAAs tend to be less tortuous, yet have greater cross-sectional diameter asymmetry. On conventional two-dimensional CT axial sections, it appears that when diameter asymmetry is associated with low aortic tortuosity, the larger diameter on axial sections more accurately reflects rupture risk, and when diameter asymmetry is associated with moderate or severe aortic tortuosity, the smaller diameter on axial sections more accurately reflects rupture risk. Current smoking is significantly associated with rupture, even when controlling for gender and AAA anatomy.

  13. Cross-correlation-based transverse flow measurements using optical resolution photoacoustic microscopy with a digital micromirror device

    PubMed Central

    Liang, Jinyang; Zhou, Yong; Maslov, Konstantin I.

    2013-01-01

    Abstract. A cross-correlation-based method is proposed to quantitatively measure transverse flow velocity using optical resolution photoacoustic (PA) microscopy enhanced with a digital micromirror device (DMD). The DMD is used to alternately deliver two spatially separated laser beams to the target. Through cross-correlation between the slow-time PA profiles measured from the two beams, the speed and direction of transverse flow are simultaneously derived from the magnitude and sign of the time shift, respectively. Transverse flows in the range of 0.50 to 6.84  mm/s are accurately measured using an aqueous suspension of 10-μm-diameter microspheres, and the root-mean-squared measurement accuracy is quantified to be 0.22  mm/s. The flow measurements are independent of the particle size for flows in the velocity range of 0.55 to 6.49  mm/s, which was demonstrated experimentally using three different sizes of microspheres (diameters: 3, 6, and 10 μm). The measured flow velocity follows an expected parabolic distribution along the depth direction perpendicular to the flow. Both maximum and minimum measurable velocities are investigated for varied distances between the two beams and varied total time for one measurement. This technique shows an accuracy of 0.35  mm/s at 0.3-mm depth in scattering chicken breast, making it promising for measuring flow in biological tissue. PMID:24002191

  14. Three-dimensional growth dynamics of the liver in the human fetus.

    PubMed

    Szpinda, Michał; Paruszewska-Achtel, Monika; Woźniak, Alina; Badura, Mateusz; Mila-Kierzenkowska, Celestyna; Wiśniewski, Marcin

    2015-07-01

    The fetal liver is indubitably the earliest and the most severely affected organ by abnormal fetal growth. The size of the fetal liver assessed by three-dimensional ultrasonography is indispensable in determining the status of fetal growth, nutrition and maturity, and in the early recognition and monitoring fetal micro- and macrosomias. The aim of the present study was to measure the human fetal liver length, transverse and sagittal diameters to establish their age-specific reference intervals, the 3rd, 10th, 50th, 90th, and 97th smoothed centile curves, and the relative growth of the liver calculated for the 50th centile. Using anatomical, digital (NIS-Elements AR 3.0, Nikon) and statistical methods (one-way ANOVA test for paired data and post hoc RIR Tukey test, Shapiro-Wilk test, Fisher's test, Student's t test, the Altman-Chitty method), length, transverse and sagittal diameters of the liver for the 3rd, 10th, 50th, 90th, and 97th centiles were assessed in 69 human fetuses of both sexes (32 males and 37 females) aged 18-30 weeks, derived from spontaneous abortions or stillbirths. No male-female differences (P > 0.05) concerning the three parameters studied were found. During the study period, the fetal liver increased tri-dimensionally: in length from 19.51 ± 1.02 to 39.65 ± 7.05 mm, in transverse diameter from 29.44 ± 3.73 to 53.13 ± 5.31 mm, and in sagittal diameter from 22.97 ± 3.79 to 43.22 ± 5.49 mm. The natural logarithmic models were found to fit the data with gestational age (P < 0.001) in the following five cutoff points: 3rd, 10th, 50th, 90th and 97th centiles. The values of liver parameters in relation to gestational age in weeks were calculated by the following logarithmic regressions: y = -82.778 + 35.752 × ln(age) ± Z × (-2.778 + 0.308 × age) for liver length, y = -123.06 + 52.668 × ln(age) ± Z × (3.156 + 0.049 × age) for liver transverse diameter, and y = -108.94 + 46.052 × ln(age) ± Z × (-0.541 + 0.188 × age) for liver sagittal diameter. For the 50th centile, at the range of 18-30 weeks, the growth rates per week were gradually decreasing from 1.93 to 1.21 mm for length, from 2.85 to 1.79 mm for transverse diameter, and from 2.49 to 1.56 mm for sagittal diameter of the liver (P < 0.05). During the study period both the length-to-transverse diameter ratio and the sagittal-to-transverse diameter ratio of the liver changed little, attaining the values of 0.71 ± 0.11 and 0.87 ± 0.12, respectively. The fetal liver does not reveal sex differences in its length, transverse and sagittal diameters. The fetal liver length, transverse and sagittal diameters grow logarithmically. The regression equations for the estimation of the mean and standard deviation of liver length, transverse and sagittal diameters allow for calculating any desired centiles according to gestational age. The three-dimensional evolution of the fetal liver follows proportionately. The age-specific reference intervals for evolving liver length, transverse and sagittal diameters constitute the normative values of potential relevance in monitoring normal fetal development and screening for disturbances in fetal growth.

  15. Optimal radial force and size for palliation in gastroesophageal adenocarcinoma: a comparative analysis of current stent technology.

    PubMed

    Mbah, Nsehniitooh; Philips, Prejesh; Voor, Michael J; Martin, Robert C G

    2017-12-01

    The optimal use of esophageal stents for malignant and benign esophageal strictures continues to be plagued with variability in pain tolerance, migration rates, and reflux-related symptoms. The aim of this study was to evaluate the differences in radial force exhibited by a variety of esophageal stents with respect to the patient's esophageal stricture. Radial force testing was performed on eight stents manufactured by four different companies using a hydraulic press and a 5000 N force gage. Radial force was measured using three different tests: transverse compression, circumferential compression, and a three-point bending test. Esophageal stricture composition and diameters were measured to assess maximum diameter, length, and proximal esophageal diameter among 15 patients prior to stenting. There was a statistically significant difference in mean radial force for transverse compression tests at the middle (range 4.25-0.66 newtons/millimeter N/mm) and at the flange (range 3.32-0.48 N/mm). There were also statistical differences in mean radial force for circumferential test (ranged from 1.19 to 10.50 N/mm, p < 0.001) and the three-point bending test (range 0.08-0.28 N/mm, p < 0.001). In an evaluation of esophageal stricture diameters and lengths, the smallest median diameter of the stricture was 10 mm (range 5-16 mm) and the median proximal diameter normal esophagus was 25 mm (range 22-33 mm), which is currently outside of the range of stent diameters. Tested stents demonstrated significant differences in radial force, which provides further clarification of stent pain and intolerance in certain patients, with either benign or malignant disease. Similarly, current stent diameters do not successfully exclude the proximal esophagus, which can lead to obstructive-type symptoms. Awareness of radial force, esophageal stricture composition, and proximal esophageal diameter must be known and understood for optimal stent tolerance.

  16. Irradiation of TZM: Uranium dioxide fuel pin at 1700 K

    NASA Technical Reports Server (NTRS)

    Mcdonald, G. E.

    1973-01-01

    A fuel pin clad with TZM and containing solid pellets of uranium dioxide was fission heated in a static helium-cooled capsule at a maximum surface temperature of 1700 K for approximately 1000 hr and to a total burnup of 2.0 percent of the uranium-235. The results of the postirradiation examination indicated: (1) A transverse, intergranular failure of the fuel pin occurred when the fuel pin reached 2.0-percent burnup. This corresponds to 1330 kW-hr/cu cm, where the volume is the sum of the fuel, clad, and void volumes in the fuel region. (2) The maximum swelling of the fuel pin was less than 1.5 percent on the fuel-pin diameter. (3) There was no visible interaction between the TZM clad and the UO2. (4) Irradiation at 1700 K produced a course-grained structure, with an average grain diameter of 0.02 centimeter and with some of the grains extending one-half of the thickness of the clad. (5) Below approximately 1500 K, the irradiation of the clad produced a moderately fine-grained structure, with an average grain diameter of 0.004 centimeter.

  17. [Morphometric anatomic study and clinical significance of lunate fossa].

    PubMed

    Aldemir, Cengiz; Önder, Merve; Doğan, Ali; Duygun, Fatih; Oğuz, Nurettin

    2015-01-01

    This study aims to investigate the depth, transverse and sagittal diameters of lunate fossa which is a significant structure of the wrist in terms of reducing the risk for volar plate screws, which are administered in distal radius fractures, from penetrating into the joint. Depth, transverse and sagittal diameters of lunate fossa in 50 right and 50 left adult dried radius bones without distal tip damage were measured by using MicroscribeG2X from the MicroScribe G series. Mean lunate fossa depth: left 2.419886±0.51 mm/right 2.543052±0.78 mm, mean lunate fossa sagittal diameter: left 19.656±1.57 mm/right 18.796±1.53 mm, mean lunate fossa transverse diameter: left 11.382±0.65 mm/right 11.106±0.91 mm. There was no statistically significant difference between right and left depth values of lunate fossa (p=0.320), whereas there was statistically significant difference between right and left transverse and sagittal diameters (p=0.006, p=0.048). Measurements involving depth of lunate fossa may guide the development of new anatomic plates and decrease complications like the penetration of screw into joint whilst volar plate administrations.

  18. Transverse Cervical Artery: Consistent Anatomical Landmarks and Clinical Experience with Its Use as a Recipient Artery in Complex Head and Neck Reconstruction.

    PubMed

    Tessler, Oren; Gilardino, Mirko S; Bartow, Matthew J; St Hilaire, Hugo; Womac, Daniel; Dionisopoulos, Tassos; Lessard, Lucie

    2017-03-01

    Many head and neck reconstructions occur in patients with extensive history of surgery or radiation treatment. This leads to complicated free flap reconstructions, especially in choosing recipient vessels in a "frozen neck." The transverse cervical artery is an optimal second-line recipient artery in head and neck reconstruction. Seventy-two neck sides in 36 cadavers were dissected, looking for the transverse cervical artery and transverse cervical vein. Anatomical location of these vessels, their diameter, and length were documented. A retrospective analysis on 19 patients who had head and neck reconstruction using the transverse cervical artery as a recipient artery was undertaken as well with regard to outcome of procedures, reason for surgery, previous operations, and use of vein grafts during surgery. The transverse cervical artery was present in 72 of 72 of cadaveric specimens, and was infraclavicular in two of 72 specimens. Transverse cervical artery length ranged from 4.0 to 7.0 cm, and the mean diameter was 2.65 mm. The transverse cervical vein was present in 61 of 72 cadaveric specimens, the length ranged from 4.0 to 7.0 cm, and the mean diameter was 2.90 mm. The transverse cervical artery averaged 33 mm from midline, and branched off the thyrocervical trunk at an average 17 mm superior to the clavicle. Transverse cervical artery stenosis was markedly less in comparison with external carotid artery stenosis. In a 20-year clinical follow-up study, the transverse cervical artery was the recipient artery in 19 patients. A vein graft was used in one patient, and no flap loss occurred in any of the 19 patients. The transverse cervical artery is a reliable and robust option as a recipient artery in free flap head and neck reconstruction.

  19. The risk of translaminar screw fixation to the transverse foramen of the lower cervical spine: a computed tomography study.

    PubMed

    Kong, Ganggang; Ji, Wei; Huang, Zucheng; Liu, Junhao; Chen, Jianting; Zhu, Qingan

    2017-04-21

    Translaminar screw fixation (TSF) of the axis is considered as an efficient, safe and simple surgical procedure, however the study of the potential risk of TSF to the transverse foramen in lower cervical spine is lacked. Head-neck CT images of 60 patients were included in this study. Maximum screw length, laminar thickness, the screw angle and the laminar height were measured. The feasibility of 3.5-mm diameter screw fixation and the potential risk of transverse foramen injury was analyzed. The TSF was safe at C3 and C4, but risky to the transverse foraman at a rate of 8.7% at C5 (0% on the left side and 20% on the right side), 33.3% at C6 (24.4% on the left side and 42.9% on the right side). C7 had the highest 77.8% rate (65.5% on the left side and 89.8% on the right side). The safe screw length was 27.7 mm at C3, 27.4 mm at C4, 28.0 mm at C5, 25.6 mm at C6 and 25.5 mm at C7, respectively. The present study showed that translaminar screw could place the transverse foramen of C5-C7 at risk. Preoperative CT scanning was necessary for safe screw placement.

  20. [Three-dimensional computed tomography analysis and clinical application of sacroiliac screw placement].

    PubMed

    Yin, Y C; Zhang, R P; Li, S L; Hou, Z Y; Chen, W; Zhang, Y Z

    2018-03-01

    Objective: To evaluate the possibility of transverse sacroiliac screw placement in different segments of the sacrum. Methods: Data of 80 pelvic CT scans (slice thickness ≤1.0 mm) archived in CT department of the Third Hospital of Hebei Medical University from September 2016 to October 2017 were retrospectively collected. Mimics software was used to rebuild the pelvis three-dimensional model. According to whether the sacral 1(S(1)) segment could place the transverse sacroiliac screws or not, all the sacrums were divided into normal group ( n =55) and dysmorphic group ( n =25). Simulation the S(1), sacral 2(S(2)) transverse sacroiliac screw placement in 3-Matic software. Analysis whether there was any difference in maximum diameter and length of S(2) transverse sacroiliac screw between the normal group and the dysmorphic group. The pelvic CT data of the dysmorphic group were measured, and the optimal tilt angle and length of the oblique S(1) screw were obtained. The feasibility of transverse sacroiliac screw insertion in sacral 3(S(3)) segment was evaluated. t -test, rank sum test, and χ(2) test was used to analyze data, respectively. Results: In the dysmorphic group, the largest diameter of the S(1) transverse screw was (4.9±1.6)mm, and the normal group was (13.6±3.6)mm ( t =-15.07, P =0.00). In the dysmorphic group, the largest diameter of S(2) transverse screw was (13.8±3.0)mm, and was (12.4±2.2)mm in the normal group( t =2.11, P =0.04). There was no significant difference in the length of S(2) transverse sacroiliac screw between the two groups ( t =0.47, P =0.64). In the dysmorphic group, the anterior vertebral height of S(1) was (23.1±4.0)mm, which was significantly higher than that of the normal group ((14.1±4.2)mm)( t =9.01, P =0.00). The angle of S(1)S(2) in the dysmorphic group was 10.9°(3.8°, 17.6°), which was significantly larger than that of the normal group (2.0°(1.0°, 2.0°) ( Z =-4.03, P =0.00). In the dysmorphic group, the incline angle of the oblique S(1) sacroiliac screw was (35.6±6.2)°, the anteversion angle was (37.2±4.4)°, and the mean screw length was (90.2±4.7)mm. In the dysmorphic group, the placement rate of S(3) transverse sacroiliac screw was 48.0%, and that of the normal sacral group was 9.1%. Conclusions: There is often dysmorphic in the sacrum in patients with large S(1) anterior vertebral height and S(1)S(2) angle. Sacral dysmorphic patients with posterior pelvic ring injury may be treated with S(1) pedicle oblique sacroiliac screws. S(3) transverse sacroiliac screws should be carefully placed, especially for the absence of sacral dysmorphic in patients.

  1. Force-length relationship in the pelvic floor muscles under transverse vaginal distension: a method study in healthy women.

    PubMed

    Verelst, M; Leivseth, G

    2004-01-01

    The purpose of this study was to investigate whether there is a relationship between changes in the diameter of the urogenital hiatus and force developed in pelvic floor musculature. In addition, we wanted to examine the reliability of the method that measures force development in the pelvic floor in the transverse direction of the urogenital hiatus. Passive and total force in the pelvic floor was measured with an intra-vaginal device in 20 healthy parous volunteers. The measurements were done with a consecutively increasing diameter in the transverse plane of the urogenital hiatus. The procedure was repeated with a few days interval. The measurements show an increase in force with an increasing device-diameter. The results are reliable at all the diameters tested, estimated by the within-subject day-to-day variability which was non-significant. The 40 mm diameter device is most favourable, estimated by Bland Altman plots of the test-retest measurements. Force development in pelvic floor muscles increased as a function of vaginal diameter when measured in the frontal plane. The measurements were reliable at all the different diameters chosen. 2004 Wiley-Liss, Inc.

  2. Variations in Eyeball Diameters of the Healthy Adults

    PubMed Central

    Bekerman, Inessa; Gottlieb, Paul

    2014-01-01

    The purpose of the current research was to reevaluate the normative data on the eyeball diameters. Methods. In a prospective cohort study, the CT data of consecutive 250 adults with healthy eyes were collected and analyzed, and sagittal, transverse, and axial diameters of both eyeballs were measured. The data obtained from the left eye and from the right eye were compared. The correlation analysis was performed with the following variables: orbit size, gender, age, and ethnic background. Results. We did not find statistically significant differences correlated with gender of the patients and their age. The right eyeball was slightly smaller than the left one but this difference was statistically insignificant (P = 0.17). We did not find statistically significant differences of the eyeball sizes among the ethnicities we dealt with. Strong correlation was found between the transverse diameter and the width of the orbit (r = 0.88). Conclusion. The size of a human adult eye is approximately 24.2 mm (transverse) × 23.7 mm (sagittal) × 22.0–24.8 mm (axial) with no significant difference between sexes and age groups. In the transverse diameter, the eyeball size may vary from 21 mm to 27 mm. These data might be useful in ophthalmological, oculoplastic, and neurological practice. PMID:25431659

  3. Variations in eyeball diameters of the healthy adults.

    PubMed

    Bekerman, Inessa; Gottlieb, Paul; Vaiman, Michael

    2014-01-01

    The purpose of the current research was to reevaluate the normative data on the eyeball diameters. Methods. In a prospective cohort study, the CT data of consecutive 250 adults with healthy eyes were collected and analyzed, and sagittal, transverse, and axial diameters of both eyeballs were measured. The data obtained from the left eye and from the right eye were compared. The correlation analysis was performed with the following variables: orbit size, gender, age, and ethnic background. Results. We did not find statistically significant differences correlated with gender of the patients and their age. The right eyeball was slightly smaller than the left one but this difference was statistically insignificant (P = 0.17). We did not find statistically significant differences of the eyeball sizes among the ethnicities we dealt with. Strong correlation was found between the transverse diameter and the width of the orbit (r = 0.88). Conclusion. The size of a human adult eye is approximately 24.2 mm (transverse) × 23.7 mm (sagittal) × 22.0-24.8 mm (axial) with no significant difference between sexes and age groups. In the transverse diameter, the eyeball size may vary from 21 mm to 27 mm. These data might be useful in ophthalmological, oculoplastic, and neurological practice.

  4. Determination of cardiac size from chest roentgenograms following Skylab missions

    NASA Technical Reports Server (NTRS)

    Nicogossian, A. E.; Hoffler, G. W.; Johnson, R. L.; Gowen, R. J.

    1974-01-01

    Decreased cardiothoracic transverse diameter ratios following Mercury, Gemini and Apollo space flights have been reported previously. To evaluate further changes in cardiac size, standard posteroanterior chest films in systole and diastole were obtained before flight and within a few hours after recovery on each of the Skylab astronauts. Postflight chest X-rays were visually compared to the preflight roentgenograms for possible changes in pulmonary vasculature, lung parenchyma, bony or soft tissue structures. From these roentgenograms the following measurements were obtained: cardiac and thoracic transverse diameters, cardiothoracic transverse diameter ratio, cardiac area from the product of both diagonal diameters, cardiac silhouette area by planimetry, thoracic cage area and cardiothoracic area ratio. The postflight frontal cardiac silhouette sizes were significantly decreased when compared with the respective preflight values (P0.05 or 0.01). The observed changes are thought to be related to postflight decrease in the intracardiac chamber volume.

  5. Observation of transverse Anderson localization in an optical fiber.

    PubMed

    Karbasi, Salman; Mirr, Craig R; Yarandi, Parisa Gandomkar; Frazier, Ryan J; Koch, Karl W; Mafi, Arash

    2012-06-15

    We utilize transverse Anderson localization as the waveguiding mechanism in optical fibers with random transverse refractive index profiles. Using experiments and numerical simulations, we show that the transverse localization results in an effective propagating beam diameter that is comparable to that of a typical index-guiding optical fiber.

  6. Effects of perturbation relative phase on transverse mode instability gain

    NASA Astrophysics Data System (ADS)

    Zervas, Michalis N.

    2018-02-01

    We have shown that the relative phase between the fundamental fiber mode and the transverse perturbation affects significantly the local transverse modal instability (TMI) gain. The gain variation is more pronounced as the core diameter increases. This finding can be used in conjunction with other proposed approaches to develop efficient strategies for mitigating TMI in high power fiber amplifiers and lasers. It also provides some physical insight on the physical origin of the observed large differences in the TMI threshold dependence on core diameter for narrow and broad linewidth operation.

  7. Biometrical analysis of the shoulder joint regarding glenoid implant dimensions for arthroplasty.

    PubMed

    Kircher, Jörn; Bittersohl, Bernd; Zilkens, Christoph; Hedtmann, Achim; Krauspe, Rüdiger

    2014-05-01

    Reduced bone stock and difficult intraoperative orientation are challenges in glenoid replacement surgery. New implant designs and methods for fixation, such as locking screws, extra-long central pegs and/or central compression screws are targeting these issues. The objective of this study is the analysis of the glenoid dimension regarding maximum central peg diameter and peg length (PL), and maximum screw length (SL) for glenoid fixation. Retrospective analysis of magnetic resonance imaging (n = 50) scans. Measurement of the maximum inferior glenoid diameter (GD), SL, maximum length of a 9.9, 10 and 11.4 mm central peg (PL) in the transverse plane; glenoid version (GV), humeral head diameter (HHD). Two independent measurements. Mean age: 49.0 ± 15.7 years (17-80) (n = 20 female, 49.6 ± 16.0; n = 30 male, 48.6 ± 15.7). Mean values of measurement were GD: 28.9 ± 3.7 mm (21-39); SL: 34.1 ± 4.9 mm (26-44); PL 9.9 mm: 19.4 ± 4.3 mm (9-30); PL 10 mm: 19.0 ± 4.4 mm (8-30); PL 11.4 mm: 16.5 ± 4.1 mm (7-26) with significant gender differences (p = 0.001; p = 0.022; p = 0.001); GV: -0.6° ± 4.9° (-10 to 11); HHD: 50.0 mm ± 4.9 (41-61). There was good correlation between PL and SL (r = 0.32, p = 0.024) and for GD and PL (r = 0.61, p = 0.001; r = 0.57, p = 0.001; r = 0.96, p = 0.001). The ratio of HHD and GD was very constant with 0.6 ± 0.07. These data indicate the high interindividual variability of glenoid morphology including significant gender-related differences. The good correlation between humeral head size and GD and maximum central PL can be helpful for cases with reduced bone stock in decision-making about implant size and bone grafting.

  8. Body surface area as a key determinant of aortic root and arch dimensions in a population-based study.

    PubMed

    Wang, Yan-Li; Wang, Qing-Ling; Wang, Liang; Wu, Ying-Biao; Wang, Zhi-Bin; Cameron, James; Liang, Yu-Lu

    2013-02-01

    The associations between the aortic dimensions (of the aortic sinus, aortic annulus and aortic arch) and physiological variables have not been established in the Chinese population. The present study examined the associations among physiological variables to determine the aortic root and arch dimensions echocardiographically. The diameters of the aortic sinus, annulus and arch were measured in 1,010 subjects via 2-D echocardiography with a 3.5-MHz transducer in a trans-thoracic position. The images of the aortic sinus and aortic annulus were obtained from a standard parasternal long-axis view. The maximum diameter of the valve orifice was measured at the end of systole. The aortic arch dimension was visualized in the long-axis using a suprasternal notch window and the maximum transverse diameter was measured. Epidata 3.0, Excel 2007 and SPSS version 17.0 were used to collect and analyze the data. A total of 1,010 subjects were enrolled. The mean age was 55.0±17.0 years (range of 18 to 90 years). The body surface area (BSA) was the best predictor of all the studied physiological variables and may be used to predict aortic sinus, annulus and arch dimensions independently (r=0.54, 0.37 and 0.39, respectively). Gender, blood pressure, age and BSA are significant predictors of the aortic dimensions. Of these, BSA was the best predictor.

  9. High-resolution resonant and nonresonant fiber-scanning confocal microscope.

    PubMed

    Hendriks, Benno H W; Bierhoff, Walter C J; Horikx, Jeroen J L; Desjardins, Adrien E; Hezemans, Cees A; 't Hooft, Gert W; Lucassen, Gerald W; Mihajlovic, Nenad

    2011-02-01

    We present a novel, hand-held microscope probe for acquiring confocal images of biological tissue. This probe generates images by scanning a fiber-lens combination with a miniature electromagnetic actuator, which allows it to be operated in resonant and nonresonant scanning modes. In the resonant scanning mode, a circular field of view with a diameter of 190 μm and an angular frequency of 127 Hz can be achieved. In the nonresonant scanning mode, a maximum field of view with a width of 69 μm can be achieved. The measured transverse and axial resolutions are 0.60 and 7.4 μm, respectively. Images of biological tissue acquired in the resonant mode are presented, which demonstrate its potential for real-time tissue differentiation. With an outer diameter of 3 mm, the microscope probe could be utilized to visualize cellular microstructures in vivo across a broad range of minimally-invasive procedures.

  10. Cladding for transverse-pumped solid-state laser

    NASA Technical Reports Server (NTRS)

    Byer, Robert L. (Inventor); Fan, Tso Y. (Inventor)

    1989-01-01

    In a transverse pumped, solid state laser, a nonabsorptive cladding surrounds a gain medium. A single tranverse mode, namely the Transverse Electromagnetic (TEM) sub 00 mode, is provided. The TEM sub 00 model has a cross sectional diameter greater than a transverse dimension of the gain medium but less than a transverse dimension of the cladding. The required size of the gain medium is minimized while a threshold for laser output is lowered.

  11. Impact resistance of fiber composite blades used in aircraft turbine engines

    NASA Technical Reports Server (NTRS)

    Friedrich, L. A.; Preston, J. L., Jr.

    1973-01-01

    Resistance of advanced fiber reinforced epoxy matrix composite materials to ballistic impact was investigated as a function of impacting projectile characteristics, and composite material properties. Ballistic impact damage due to normal impacts, was classified as transverse (stress wave delamination and splitting), penetrative, or structural (gross failure). Steel projectiles were found to be gelatin ice projectiles in causing penetrative damage leading to reduced tensile strength. Gelatin and ice projectiles caused either transverse or structural damage, depending upon projectile mass and velocity. Improved composite transverse tensile strength, use of dispersed ply lay-ups, and inclusion of PRD-49-1 or S-glass fibers correlated with improved resistance of composite materials to transverse damage. In non-normal impacts against simulated blade shapes, the normal velocity component of the impact was used to correlate damage results with normal impact results. Stiffening the leading edge of simulated blade specimens led to reduced ballistic damage, while addition of a metallic leading edge provided nearly complete protection against 0.64 cm diameter steel, and 1.27 cm diameter ice and gelatin projectiles, and partial protection against 2.54 cm diameter projectiles of ice and gelatin.

  12. High energy, single-polarized, single-transverse-mode, nanosecond pulses generated by a multi-stage Yb-doped photonic crystal fiber amplifier

    NASA Astrophysics Data System (ADS)

    Shen, Xinglai; Zhang, Haitao; Hao, He; Li, Dan; Li, Qinghua; Yan, Ping; Gong, Mali

    2015-06-01

    We report the construction of a cascaded fiber amplifier where a 40-μm-core-diameter photonic crystal fiber is utilized in the main amplifier stage. Single-transverse-mode, linearly-polarized, 7.5 ns pulses with 1.5 mJ energy, 123 kW peak power and 10 nm spectral bandwidth centered at 1062 nm are generated. To our knowledge, the pulse energy we obtain is the highest from 40-μm-core-diameter photonic crystal fibers, and also the highest for long pulses (>1 ns) with linear polarization and single transverse mode.

  13. Parasitic lasing suppression in large-aperture Ti:sapphire amplifiers by optimizing the seed-pump time delay

    NASA Astrophysics Data System (ADS)

    Chu, Y. X.; Liang, X. Y.; Yu, L. H.; Xu, L.; Lu, X. M.; Liu, Y. Q.; Leng, Y. X.; Li, R. X.; Xu, Z. Z.

    2013-05-01

    Theoretical and experimental investigations are carried out to determine the influence of the time delay between the input seed pulse and pump pulses on transverse parasitic lasing in a Ti:sapphire amplifier with a diameter of 80 mm, which is clad by a refractive index-matched liquid doped with an absorber. When the time delay is optimized, a maximum output energy of 50.8 J is achieved at a pump energy of 105 J, which corresponds to a conversion efficiency of 47.5%. Based on the existing compressor, the laser system achieves a peak power of 1.26 PW with a 29.0 fs pulse duration.

  14. Femtosecond laser inscribed cladding waveguide lasers in Nd:LiYF4 crystals

    NASA Astrophysics Data System (ADS)

    Li, Shi-Ling; Huang, Ze-Ping; Ye, Yong-Kai; Wang, Hai-Long

    2018-06-01

    Depressed circular cladding, buried waveguides were fabricated in Nd:LiYF4 crystals with an ultrafast Yb-doped fiber master-oscillator power amplifier laser. Waveguides were optimized by varying the laser writing conditions, such as pulse energy, focus depth, femtosecond laser polarization and scanning velocity. Under optical pump at 799 nm, cladding waveguides showed continuous-wave laser oscillation at 1047 nm. Single- and multi-transverse modes waveguide laser were realized by varying the waveguide diameter. The maximum output power in the 40 μm waveguide is ∼195 mW with a slope efficiency of 34.3%. The waveguide lasers with hexagonal and cubic cladding geometry were also realized.

  15. Rapid Confined Mixing with Transverse Jets Part 1: Single Jet

    NASA Astrophysics Data System (ADS)

    Salazar, David; Forliti, David

    2012-11-01

    Transverse jets have been studied extensively due to their relevance and efficiency in fluid mixing applications. Gas turbine burners, film cooling, and chemical reactors are some examples of rapid transverse jet mixing. Motivated by a lack of universal scaling laws for confined and unconfined transverse jets, a newly developed momentum transfer parameter was found to improve correlation of literature data. Jet column drag and entrainment arguments for momentum transfer are made to derive the parameter. A liquid-phase mixing study was conducted to investigate confined mixing for a low number of jets. Planar laser induced fluorescence was implemented to measure mixture fraction for a single confined transverse jet. Time-averaged cross-sectional images were taken with a light sheet located three diameters downstream of transverse injection. A mixture of water and sodium fluorescein was used to distinguish jet fluid from main flow fluid for the test section images. Image data suggest regimes for under- and overpenetration of jet fluid into the main flow. The scaling parameter is found to correlate optimum unmixedness for multiple diameter ratios at a parameter value of 0.75. Distribution A: Public Release, Public Affairs Clearance Number: 12655.

  16. Infraorbital foramen: horizontal location in relation to ala nasi.

    PubMed

    Takahashi, Yasuhiro; Kakizaki, Hirohiko; Nakano, Takashi

    2011-01-01

    To examine the horizontal location of the infraorbital foramen in relation to the ala nasi. Fifty-six orbits of 28 Japanese cadavers (18 male and 10 female cadavers; average death age, 79.7 years), fixed in 10% buffered formalin, were used. The horizontal distance from the vertical line through the lateral margin of the ala nasi to the medial margin of the infraorbital foramen (the horizontal distance) and the transverse diameter of the infraorbital foramen (the transverse diameter) were examined. Values were compared between genders and sides using Student's t test. The mean horizontal distance was 4.9 mm, with no significant difference between genders (male, 5.2 mm; female, 4.4 mm; p = 0.150) or sides (right, 4.9 mm; left, 4.9 mm; p = 0.944). The mean transverse diameter was 5.5 mm. Although there was no significant difference in this diameter between sides (right, 5.3 mm; left, 5.6 mm; p = 0.358), there was a significant difference between genders (male, 5.7 mm; female, 5.1 mm; p = 0.033). The horizontal distance had no gender difference. This value is available irrespective of gender in surgery.

  17. Mucosal perforation during laparoscopic surgery for achalasia: impact of preoperative pneumatic balloon dilation.

    PubMed

    Souma, Yoshihito; Nakajima, Kiyokazu; Taniguchi, Eiji; Takahashi, Tsuyoshi; Kurokawa, Yukinori; Yamasaki, Makoto; Miyazaki, Yasuhiro; Makino, Tomoki; Hamada, Tetsuhiro; Yasuda, Jun; Yumiba, Takeyoshi; Ohashi, Shuichi; Takiguchi, Shuji; Mori, Masaki; Doki, Yuichiro

    2017-03-01

    Controversy remains whether preoperative pneumatic balloon dilation (PBD) influences the surgical outcome of laparoscopic esophagocardiomyotomy in patients with esophageal achalasia. The aim of this study was to evaluate whether preoperative PBD represents a risk factor for surgical complications and affects the symptomatic and/or functional outcomes of laparoscopic Heller myotomy with Dor fundoplication (LHD). A retrospective chart review was conducted on a prospectively compiled surgical database of 103 consecutive patients with esophageal achalasia who underwent LHD from November 1994 to September 2014. The following data were compared between the patients with preoperative PBD (PBD group; n = 26) and without PBD (non-PBD group; n = 77): (1) patients' demographics: age, gender, body mass index, duration of symptoms, maximum transverse diameter of esophagus; (2) operative findings: operating time, blood loss, intraoperative complications; (3) postoperative course: complications, clinical symptoms, postoperative treatment; and (4) esophageal functional tests: preoperative and postoperative manometric data and postoperative profile of 24-h esophageal pH monitoring. (1) No significant differences were observed in the patients' demographics. (2) Operative findings were similar between the two groups; however, the incidence of mucosal perforation was significantly higher in the PBD group (n = 8; 30.7 %) compared to the non-PBD group (n = 6; 7.7 %) (p = 0.005). (3) Postoperative complications were not encountered in either group. The differences were not significant for postoperative clinical symptoms, the incidence of gastroesophageal reflux disease, or necessity of postoperative treatments. (4) Lower esophageal sphincter pressure was effectively reduced in both groups, and no differences were observed in manometric data or 24-h pH monitoring profiles between the two groups. Multivariate logistic regression analysis showed that preoperative PBD and the maximum transverse diameter of esophagus were significantly associated with intraoperative mucosal perforation. Although postoperative outcomes were not affected, additional caution is recommended in identifying intraoperative mucosal perforation in patients with preoperative PBD when performing LHD.

  18. PHYSICAL PROPERTIES OF LARGE AND SMALL GRANULES IN SOLAR QUIET REGIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu Daren; Xie Zongxia; Hu Qinghua

    The normal mode observations of seven quiet regions obtained by the Hinode spacecraft are analyzed to study the physical properties of granules. An artificial intelligence technique is introduced to automatically find the spatial distribution of granules in feature spaces. In this work, we investigate the dependence of granular continuum intensity, mean Doppler velocity, and magnetic fields on granular diameter. We recognized 71,538 granules by an automatic segmentation technique and then extracted five properties: diameter, continuum intensity, Doppler velocity, and longitudinal and transverse magnetic flux density to describe the granules. To automatically explore the intrinsic structures of the granules in themore » five-dimensional parameter space, the X-means clustering algorithm and one-rule classifier are introduced to define the rules for classifying the granules. It is found that diameter is a dominating parameter in classifying the granules and two families of granules are derived: small granules with diameters smaller than 1.''44, and large granules with diameters larger than 1.''44. Based on statistical analysis of the detected granules, the following results are derived: (1) the averages of diameter, continuum intensity, and Doppler velocity in the upward direction of large granules are larger than those of small granules; (2) the averages of absolute longitudinal, transverse, and unsigned flux density of large granules are smaller than those of small granules; (3) for small granules, the average of continuum intensity increases with their diameters, while the averages of Doppler velocity, transverse, absolute longitudinal, and unsigned magnetic flux density decrease with their diameters. However, the mean properties of large granules are stable; (4) the intensity distributions of all granules and small granules do not satisfy Gaussian distribution, while that of large granules almost agrees with normal distribution with a peak at 1.04 I{sub 0}.« less

  19. Effect of ocular transverse chromatic aberration on detection acuity for peripheral vision.

    PubMed

    Cheney, Frank; Thibos, Larry; Bradley, Arthur

    2015-01-01

    We examined the effect of transverse chromatic aberration (TCA) on detection acuity for white-light interference fringes seen in Maxwellian view at various orientations and locations in the visual field. A circular patch (3.5° diameter, 3.2 log Trolands) of nominally high-contrast fringes was produced on the retina by a commercial instrument (the Lotmar Visometer, Haag Streit) mounted on a gimbal for controlled positioning of the stimulus in the visual field from 0° to 35° eccentricity. Detection acuity for white light fringes for all meridians and eccentricities ≥15° was maximum when fringes were oriented parallel to the visual meridian line. This meridional effect disappeared when a narrow-band filter was used to eliminate TCA. The meridional effect also disappeared when the interferometric stimulator was displaced laterally to align the instrument with the eye's local achromatic axis. Modelling confirmed that TCA is the major factor responsible for white-light meridional bias, with minor contribution arising from higher-order monochromatic aberrations and neural factors. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

  20. Three-dimensional workstation is useful for measuring the correct size of abdominal aortic aneurysm diameters.

    PubMed

    Ihara, Tsutomu; Komori, Kimihiro; Yamamoto, Kiyohito; Kobayashi, Masayoshi; Banno, Hiroshi; Kodama, Akio

    2013-02-01

    Abdominal aortic aneurysm diameter is usually measured by the maximum minor-axis diameter on axial computed tomography (CT). However, this "traditional" diameter may underestimate the real size, as the aorta is not always straight and the aneurysm shape is sometimes in the form of an ellipse along the cross section. Therefore, we measured maximum major-axis diameters using a three-dimensional (3D) workstation and compared them with the traditional maximum minor-axis diameters measured using thin-slice axial CT. CT data of 141 AAA patients (with fusiform aneurysms) were stored in a 3D workstation. These thin-slice CT images were reviewed on the 3D workstation to obtain curved multiplanar reconstruction images (CPR images). Using the CPR images, we measured the maximum major-axis and minor-axis diameters on CPR and the angle of the aneurysms to the body axis. The mean traditional maximum minor-axis diameter was 51.2 ± 8.2 mm, whereas the mean maximum major-axis diameter on CPR was 54.7 ± 10.1 mm. Sixty eight patients had a mean aneurysm size of <50 mm when measured by the traditional minor-axis diameter. Among these patients, five (7.4%) had a major-axis diameter >55 mm on CPR. The measurement of the traditional maximum minor-axis diameter of aneurysms is useful in the case of most patients. However, the traditional maximum minor-axis diameter may underestimate the real aneurysmal diameter, particularly in patients with an ellipse-shaped aneurysm. The maximum major-axis diameter as measured using CPR images is effective for representing the real aneurysmal size. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Transverse Coefficient of Thermal Expansion Measurements of Carbon Fibers Using ESEM at High Temperatures

    NASA Technical Reports Server (NTRS)

    Ochoa, O.; Jiang, J.; Putnam, D.; Lo, Z.; Ellis, A.; Effinger, Michael

    2003-01-01

    The transverse coefficient of thermal expansion (CTE) of single IM7, T1000, and P55 carbon fibers are measured at elevated temperatures. The specimens are prepared by press-fitting fiber tows into 0.7mm-diameter cavity in a graphite disk of 5mm in diameter and 3mm high. The specimens are placed on a crucible in an ESEM, and images of the fiber cross section are taken as the fibers are heated up to 800 C. Holding time, heating and cool down cycles are also introduced. The geometrical changes are measured using a graphics tablet. The change in area/perimeter is calculated to determine the strain and transverse CTE for each fiber. In a complimentary computational effort, displacements and stresses are calculated with finite element models.

  2. Brachial artery vasomotion and transducer pressure effect on measurements by active contour segmentation on ultrasound

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cary, Theodore W.; Sultan, Laith R.; Sehgal, Chandra M., E-mail: sehgalc@uphs.upenn.edu

    Purpose: To use feed-forward active contours (snakes) to track and measure brachial artery vasomotion on ultrasound images recorded in both transverse and longitudinal views; and to compare the algorithm's performance in each view. Methods: Longitudinal and transverse view ultrasound image sequences of 45 brachial arteries were segmented by feed-forward active contour (FFAC). The segmented regions were used to measure vasomotion artery diameter, cross-sectional area, and distention both as peak-to-peak diameter and as area. ECG waveforms were also simultaneously extracted frame-by-frame by thresholding a running finite-difference image between consecutive images. The arterial and ECG waveforms were compared as they traced eachmore » phase of the cardiac cycle. Results: FFAC successfully segmented arteries in longitudinal and transverse views in all 45 cases. The automated analysis took significantly less time than manual tracing, but produced superior, well-behaved arterial waveforms. Automated arterial measurements also had lower interobserver variability as measured by correlation, difference in mean values, and coefficient of variation. Although FFAC successfully segmented both the longitudinal and transverse images, transverse measurements were less variable. The cross-sectional area computed from the longitudinal images was 27% lower than the area measured from transverse images, possibly due to the compression of the artery along the image depth by transducer pressure. Conclusions: FFAC is a robust and sensitive vasomotion segmentation algorithm in both transverse and longitudinal views. Transverse imaging may offer advantages over longitudinal imaging: transverse measurements are more consistent, possibly because the method is less sensitive to variations in transducer pressure during imaging.« less

  3. Brachial artery vasomotion and transducer pressure effect on measurements by active contour segmentation on ultrasound.

    PubMed

    Cary, Theodore W; Reamer, Courtney B; Sultan, Laith R; Mohler, Emile R; Sehgal, Chandra M

    2014-02-01

    To use feed-forward active contours (snakes) to track and measure brachial artery vasomotion on ultrasound images recorded in both transverse and longitudinal views; and to compare the algorithm's performance in each view. Longitudinal and transverse view ultrasound image sequences of 45 brachial arteries were segmented by feed-forward active contour (FFAC). The segmented regions were used to measure vasomotion artery diameter, cross-sectional area, and distention both as peak-to-peak diameter and as area. ECG waveforms were also simultaneously extracted frame-by-frame by thresholding a running finite-difference image between consecutive images. The arterial and ECG waveforms were compared as they traced each phase of the cardiac cycle. FFAC successfully segmented arteries in longitudinal and transverse views in all 45 cases. The automated analysis took significantly less time than manual tracing, but produced superior, well-behaved arterial waveforms. Automated arterial measurements also had lower interobserver variability as measured by correlation, difference in mean values, and coefficient of variation. Although FFAC successfully segmented both the longitudinal and transverse images, transverse measurements were less variable. The cross-sectional area computed from the longitudinal images was 27% lower than the area measured from transverse images, possibly due to the compression of the artery along the image depth by transducer pressure. FFAC is a robust and sensitive vasomotion segmentation algorithm in both transverse and longitudinal views. Transverse imaging may offer advantages over longitudinal imaging: transverse measurements are more consistent, possibly because the method is less sensitive to variations in transducer pressure during imaging.

  4. Brachial artery vasomotion and transducer pressure effect on measurements by active contour segmentation on ultrasound

    PubMed Central

    Cary, Theodore W.; Reamer, Courtney B.; Sultan, Laith R.; Mohler, Emile R.; Sehgal, Chandra M.

    2014-01-01

    Purpose: To use feed-forward active contours (snakes) to track and measure brachial artery vasomotion on ultrasound images recorded in both transverse and longitudinal views; and to compare the algorithm's performance in each view. Methods: Longitudinal and transverse view ultrasound image sequences of 45 brachial arteries were segmented by feed-forward active contour (FFAC). The segmented regions were used to measure vasomotion artery diameter, cross-sectional area, and distention both as peak-to-peak diameter and as area. ECG waveforms were also simultaneously extracted frame-by-frame by thresholding a running finite-difference image between consecutive images. The arterial and ECG waveforms were compared as they traced each phase of the cardiac cycle. Results: FFAC successfully segmented arteries in longitudinal and transverse views in all 45 cases. The automated analysis took significantly less time than manual tracing, but produced superior, well-behaved arterial waveforms. Automated arterial measurements also had lower interobserver variability as measured by correlation, difference in mean values, and coefficient of variation. Although FFAC successfully segmented both the longitudinal and transverse images, transverse measurements were less variable. The cross-sectional area computed from the longitudinal images was 27% lower than the area measured from transverse images, possibly due to the compression of the artery along the image depth by transducer pressure. Conclusions: FFAC is a robust and sensitive vasomotion segmentation algorithm in both transverse and longitudinal views. Transverse imaging may offer advantages over longitudinal imaging: transverse measurements are more consistent, possibly because the method is less sensitive to variations in transducer pressure during imaging. PMID:24506648

  5. Analysis of lumbar pedicle morphology in degenerative spines using multiplanar reconstruction computed tomography: what can be the reliable index for optimal pedicle screw diameter?

    PubMed

    Makino, Takahiro; Kaito, Takashi; Fujiwara, Hiroyasu; Yonenobu, Kazuo

    2012-08-01

    The measurement of transverse pedicle width is still recommended for selecting a screw diameter despite being weakly correlated with the minimum pedicle diameter, except in the upper lumbar spine. The purpose of this study was to reveal the difference between the minimum pedicle diameter and conventional transverse or sagittal pedicle width in degenerative lumbar spines. A total of 50 patients with degenerative lumbar disorders without spondylolysis or lumbar scoliosis of >10° who preoperatively underwent helical CT scans were included. The DICOM data of the scans were reconstructed by imaging software, and the transverse pedicle width (TPW), sagittal pedicle width (SPW), minimum pedicle diameter (MPD), and the cephalocaudal inclination of the pedicles were measured. The mean TPW/SPW/MPD values were 5.46/11.89/5.09 mm at L1, 5.76/10.44/5.39 mm at L2, 7.25/10.23/6.52 mm at L3, 9.01/9.36/6.83 mm at L4, and 12.86/8.95/7.36 mm at L5. There were significant differences between the TPW and MPD at L3, L4, and L5 (p < 0.01) and between the SPW and MPD at all levels (p < 0.01). The MPD was significantly smaller than the TPW and SPW at L3, L4, and L5. The actual measurements of the TPW were not appropriate for use as a direct index for the optimal pedicle screw diameter at these levels. Surgeons should be careful in determining pedicle screw diameter based on plain CT scans especially in the lower lumbar spine.

  6. Effects of tool handle dimension and workpiece orientation and size on wrist ulnar/radial torque strength, usability and discomfort in a wrench task.

    PubMed

    Dianat, Iman; Rahimi, Soleyman; Nedaei, Moein; Asghari Jafarabadi, Mohammad; Oskouei, Ali E

    2017-03-01

    The effects of tool handle dimension (three modified designs of wrenches with 30-50 mm diameter cylindrical handles and traditional design with rectangular cross-sectional (5 mm × 25 mm) handle), workpiece orientation (vertical/horizontal) and workpiece size (small/large) as well as user's hand size on wrist ulnar/radial (U/R) torque strength, usability and discomfort, and also the relationship between these variables were evaluated in a maximum torque task using wrenches. The highest and lowest levels of maximal wrist U/R torque strength were recorded for the 30 mm diameter handle and traditional wrench design, respectively. The prototype handle with 30 mm diameter, together with 40 mm diameter handle, was also better than other designs as they received higher usability ratings and caused less discomfort. The mean wrist torque strength exerted on a vertically oriented workpiece (in the sagittal plane) was 23.8% higher than that exerted on a horizontally oriented one (in the transverse plane). The user's hand size had no effect on torque exertions. The wrist torque strength and usability were negatively correlated with hand and finger discomfort ratings. The results are also discussed in terms of their implications for hand tool and workstation configuration in torque tasks involving wrenches. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. The use of non‐adult vertebral dimensions as indicators of growth disruption and non‐specific health stress in skeletal populations

    PubMed Central

    Gowland, Rebecca L.

    2015-01-01

    ABSTRACT Objective Traditional methods of detecting growth disruption have focused on deficiencies in the diaphyseal length of the long bones. This study proposes the implementation of vertebral measurements (body height and transverse diameter of the neural canal) from non‐adults (0–17 years) as a new methodology for the identification of growth disruption. Methods Measurements of vertebral body height and transverse diameter were taken from 96 non‐adult skeletons and 40 adult skeletons from two post‐medieval sites in England (Bow Baptist, London and Coronation Street, South Shields). Non‐adult measurements were plotted against dental age to construct vertebral growth profiles through which inter‐population comparisons could be made. Results Results demonstrated that both sites experienced some growth retardation in infancy, evident as deficiencies in transverse diameter. However, analysis of vertebral body height revealed different chronologies of growth disruption between the sites, with a later age of attainment of skeletal maturity recorded in the Bow Baptist sample. Discussion These vertebral dimensions undergo cessation of growth at different ages, with transverse diameter being “locked‐in” by ∼1–2 years of age, while vertebral body height may continue to grow into early adulthood. These measurements can therefore provide complementary information regarding the timing of growth disruption within archaeological populations. Non‐adult vertebral measurements can increase our osteobiographical understanding of the timings of episodes of health stress, and allow for the analysis of growth when other skeletal elements are fragmentary. Am J Phys Anthropol 158:155–164, 2015. © 2015 Wiley Periodicals, Inc. PMID:26118898

  8. Evaluation of normal abdominal aortic diameters in the Indian population using computed tomography.

    PubMed

    Jasper, A; Harshe, G; Keshava, S N; Kulkarni, G; Stephen, E; Agarwal, S

    2014-01-01

    The aim of this study was to establish normal diameters for the suprarenal and infrarenal abdominal aorta measured at T12 and L3 vertebral levels in the Indian population and to study the variation in aortic diameters with age, sex, height, weight, body mass index (BMI), and body surface area (BSA). One hundred and forty-two patients who underwent helical contrast-enhanced computed tomography (CT) scans of the abdomen for non-cardiovascular reasons were recruited.. The mean internal diameters of the suprarenal and infrarenal abdominal aorta (maximum anteroposterior and transverse diameter) were measured at T12 and L3 vertebral levels and tabulated according to various age groups for both men and women. Pearson correlation coefficient was used to evaluate the correlation between aortic diameters, height, weight, BSA, and BMI. The mean diameters of the suprarenal and infrarenal abdominal aorta measured at T12 and L3 vertebral levels, in men were 19.0 ± 2.3 and 13.8 ± 1.9 mm and in women 17.1 ± 2.3 and 12.0 ± 1.6 mm, respectively. The aortic diameter progressively increased in caliber with increasing age of the patients and was smaller in women than men. A significant positive correlation was found in men between the suprarenal and infrarenal aortic diameters and weight, BSA, and BMI. In women, this correlation was significant in the infrarenal aorta but not in the suprarenal aorta. We obtained a set of normal values for the abdominal aorta in the Indian population. The aortic diameters correlated with age, gender, and body size of the patients as seen with previously published data in the Western population. A brief comparison of data between Indian and Western population showed that the values obtained were less than published elsewhere and hence, this should be considered while formulating intervention protocols.

  9. Correlation between morphometry of the suprascapular notch and anthropometric measurements of the scapula.

    PubMed

    Polguj, M; Jędrzejewski, K S; Podgórski, M; Topol, M

    2011-05-01

    The concept of the study was to find the correlation between the morphometry of the suprascapular notch and basic anthropometric measurements of the human scapula. The measurements of the human scapulae included: morphological length and width, maximal width and length projection of scapular spine, length of acromion, and maximal length of the coracoid process. The glenoid cavity was measured in two perpendicular directions to evaluate its width and length. The width-length scapular and glenoid cavity indexes were calculated for every bone. In addition to standard anthropometric measurements two other measurements were defined and evaluated for every suprascapular notch: maximal depth (MD) and superior transverse diameter (STD). The superior transverse suprascapular ligament was completely ossified in 7% of cases. Ten (11.6%) scapulae had a discrete notch. In the studied material, in 21 (24.4%) scapulae the MD was longer than the STD. Two (2.3%) scapulae had equal maximal depth and superior transverse diameter. In 47 (57.7%) scapulae the superior transverse diameter was longer than the maximal depth. There was no statistically significant difference between anthropometric measurements in the group with higher MD and the group with higher STD. The maximal depth of the suprascapular notch negatively correlated with the scapular width-length index. The maximal depth of the scapular notch correlated with the morphological length of the scapulae.

  10. A genome-wide association study identifies candidate loci associated to syringomyelia secondary to Chiari-like malformation in Cavalier King Charles Spaniels.

    PubMed

    Ancot, Frédéric; Lemay, Philippe; Knowler, Susan P; Kennedy, Karen; Griffiths, Sandra; Cherubini, Giunio Bruto; Sykes, Jane; Mandigers, Paul J J; Rouleau, Guy A; Rusbridge, Clare; Kibar, Zoha

    2018-03-22

    Syringomyelia (SM) is a common condition affecting brachycephalic toy breed dogs and is characterized by the development of fluid-filled cavities within the spinal cord. It is often concurrent with a complex developmental malformation of the skull and craniocervical vertebrae called Chiari-like malformation (CM) characterized by a conformational change and overcrowding of the brain and cervical spinal cord particularly at the craniocervical junction. CM and SM have a polygenic mode of inheritance with variable penetrance. We identified six cranial T1-weighted sagittal MRI measurements that were associated to maximum transverse diameter of the syrinx cavity. Increased syrinx transverse diameter has been correlated previously with increased likelihood of behavioral signs of pain. We next conducted a whole genome association study of these traits in 65 Cavalier King Charles Spaniel (CKCS) dogs (33 controls, 32 with extreme phenotypes). Two loci on CFA22 and CFA26 were found to be significantly associated to two traits associated with a reduced volume and altered orientation of the caudal cranial fossa. Their reconstructed haplotypes defined two associated regions that harbor only two genes: PCDH17 on CFA22 and ZWINT on CFA26. PCDH17 codes for a cell adhesion molecule expressed specifically in the brain and spinal cord. ZWINT plays a role in chromosome segregation and its expression is increased with the onset of neuropathic pain. Targeted genomic sequencing of these regions identified respectively 37 and 339 SNPs with significantly associated P values. Genotyping of tagSNPs selected from these 2 candidate loci in an extended cohort of 461 CKCS (187 unaffected, 274 SM affected) identified 2 SNPs on CFA22 that were significantly associated to SM strengthening the candidacy of this locus in SM development. We identified 2 loci on CFA22 and CFA26 that contained only 2 genes, PCDH17 and ZWINT, significantly associated to two traits associated with syrinx transverse diameter. The locus on CFA22 was significantly associated to SM secondary to CM in the CKCS dog breed strengthening its candidacy for this disease. This study will provide an entry point for identification of the genetic factors predisposing to this condition and its underlying pathogenic mechanisms.

  11. Laser properties of Fe2+:ZnSe fabricated by solid-state diffusion bonding

    NASA Astrophysics Data System (ADS)

    Balabanov, S. S.; Firsov, K. N.; Gavrishchuk, E. M.; Ikonnikov, V. B.; Kazantsev, S. Yu; Kononov, I. G.; Kotereva, T. V.; Savin, D. V.; Timofeeva, N. A.

    2018-04-01

    The characteristics of an Fe2+:ZnSe laser at room temperature and its active elements with undoped faces were studied. Polycrystalline elements with one or two diffusion-doped internal layers were obtained by the solid-state diffusion bonding technique applied to chemical vapor deposition grown ZnSe plates preliminary doped with Fe2+ ions in the process of hot isostatic pressing. A non-chain electric-discharge HF laser was used to pump the crystals. It was demonstrated that increasing the number of doped layers allows increasing the maximum diameter of the pump radiation spot and the pump energy without the appearance of transversal parasitic oscillation. For the two-layer-doped active element with a diameter of 20 mm an output energy of 480 mJ was achieved with 37% total efficiency with respect to the absorbed energy. The obtained results demonstrate the potential of the developed technology for fabrication of active elements by the solid-state diffusion bonding technique combined with the hot isostatic pressing treatment for efficient IR lasers based on chalcogenides doped with transition metal ions.

  12. Thermal resistance of etched-pillar vertical-cavity surface-emitting laser diodes

    NASA Astrophysics Data System (ADS)

    Wipiejewski, Torsten; Peters, Matthew G.; Young, D. Bruce; Thibeault, Brian; Fish, Gregory A.; Coldren, Larry A.

    1996-03-01

    We discuss our measurements on thermal impedance and thermal crosstalk of etched-pillar vertical-cavity lasers and laser arrays. The average thermal conductivity of AlAs-GaAs Bragg reflectors is estimated to be 0.28 W/(cmK) and 0.35W/(cmK) for the transverse and lateral direction, respectively. Lasers with a Au-plated heat spreading layer exhibit a 50% lower thermal impedance compared to standard etched-pillar devices resulting in a significant increase of maximum output power. For an unmounted laser of 64 micrometer diameter we obtain an improvement in output power from 20 mW to 42 mW. The experimental results are compared with a simple analytical model showing the importance of heat sinking for maximizing the output power of vertical-cavity lasers.

  13. Maximum Diameter Measurements of Aortic Aneurysms on Axial CT Images After Endovascular Aneurysm Repair: Sufficient for Follow-up?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baumueller, Stephan, E-mail: Stephan.Baumueller@usz.ch; Nguyen, Thi Dan Linh, E-mail: ThiDanLinh.Nguyen@usz.ch; Goetti, Robert Paul, E-mail: RobertPaul.Goetti@usz.ch

    2011-12-15

    Purpose: To assess the accuracy of maximum diameter measurements of aortic aneurysms after endovascular aneurysm repair (EVAR) on axial computed tomographic (CT) images in comparison to maximum diameter measurements perpendicular to the intravascular centerline for follow-up by using three-dimensional (3D) volume measurements as the reference standard. Materials and Methods: Forty-nine consecutive patients (73 {+-} 7.5 years, range 51-88 years), who underwent EVAR of an infrarenal aortic aneurysm were retrospectively included. Two blinded readers twice independently measured the maximum aneurysm diameter on axial CT images performed at discharge, and at 1 and 2 years after intervention. The maximum diameter perpendicular tomore » the centerline was automatically measured. Volumes of the aortic aneurysms were calculated by dedicated semiautomated 3D segmentation software (3surgery, 3mensio, the Netherlands). Changes in diameter of 0.5 cm and in volume of 10% were considered clinically significant. Intra- and interobserver agreements were calculated by intraclass correlations (ICC) in a random effects analysis of variance. The two unidimensional measurement methods were correlated to the reference standard. Results: Intra- and interobserver agreements for maximum aneurysm diameter measurements were excellent (ICC = 0.98 and ICC = 0.96, respectively). There was an excellent correlation between maximum aneurysm diameters measured on axial CT images and 3D volume measurements (r = 0.93, P < 0.001) as well as between maximum diameter measurements perpendicular to the centerline and 3D volume measurements (r = 0.93, P < 0.001). Conclusion: Measurements of maximum aneurysm diameters on axial CT images are an accurate, reliable, and robust method for follow-up after EVAR and can be used in daily routine.« less

  14. 10-channel fiber array fabrication technique for parallel optical coherence tomography system

    NASA Astrophysics Data System (ADS)

    Arauz, Lina J.; Luo, Yuan; Castillo, Jose E.; Kostuk, Raymond K.; Barton, Jennifer

    2007-02-01

    Optical Coherence Tomography (OCT) shows great promise for low intrusive biomedical imaging applications. A parallel OCT system is a novel technique that replaces mechanical transverse scanning with electronic scanning. This will reduce the time required to acquire image data. In this system an array of small diameter fibers is required to obtain an image in the transverse direction. Each fiber in the array is configured in an interferometer and is used to image one pixel in the transverse direction. In this paper we describe a technique to package 15μm diameter fibers on a siliconsilica substrate to be used in a 2mm endoscopic probe tip. Single mode fibers are etched to reduce the cladding diameter from 125μm to 15μm. Etched fibers are placed into a 4mm by 150μm trench in a silicon-silica substrate and secured with UV glue. Active alignment was used to simplify the lay out of the fibers and minimize unwanted horizontal displacement of the fibers. A 10-channel fiber array was built, tested and later incorporated into a parallel optical coherence system. This paper describes the packaging, testing, and operation of the array in a parallel OCT system.

  15. Enhancement of maximum attainable ion energy in the radiation pressure acceleration regime using a guiding structure

    DOE PAGES

    Bulanov, S. S.; Esarey, E.; Schroeder, C. B.; ...

    2015-03-13

    Radiation Pressure Acceleration is a highly efficient mechanism of laser driven ion acceleration, with the laser energy almost totally transferrable to the ions in the relativistic regime. There is a fundamental limit on the maximum attainable ion energy, which is determined by the group velocity of the laser. In the case of a tightly focused laser pulses, which are utilized to get the highest intensity, another factor limiting the maximum ion energy comes into play, the transverse expansion of the target. Transverse expansion makes the target transparent for radiation, thus reducing the effectiveness of acceleration. Utilization of an external guidingmore » structure for the accelerating laser pulse may provide a way of compensating for the group velocity and transverse expansion effects.« less

  16. Epidemiology and contemporary management of abdominal aortic aneurysms.

    PubMed

    Ullery, Brant W; Hallett, Richard L; Fleischmann, Dominik

    2018-05-01

    Abdominal aortic aneurysm (AAA) is most commonly defined as a maximal diameter of the abdominal aorta in excess of 3 cm in either anterior-posterior or transverse planes or, alternatively, as a focal dilation ≥ 1.5 times the diameter of the normal adjacent arterial segment. Risk factors for the development of AAA include age > 60, tobacco use, male gender, Caucasian race, and family history of AAA. Aneurysm growth and rupture risk appear to be associated with persistent tobacco use, female gender, and chronic pulmonary disease. The majority of AAAs are asymptomatic and detected incidentally on various imaging studies, including abdominal ultrasound, and computed tomographic angiography. Symptoms associated with AAA may include abdominal or back pain, thromboembolization, atheroembolization, aortic rupture, or development of an arteriovenous or aortoenteric fistula. The Screening Abdominal Aortic Aneurysms Efficiently (SAAAVE) Act provides coverage for a one-time screening abdominal ultrasound at age 65 for men who have smoked at least 100 cigarettes and women who have family history of AAA disease. Medical management is recommended for asymptomatic patients with AAAs < 5 cm in diameter and focuses on modifiable risk factors, including smoking cessation and blood pressure control. Primary indications for intervention in patients with AAA include development of symptoms, rupture, rapid aneurysm growth (> 5 mm/6 months), or presence of a fusiform aneurysm with maximum diameter of 5.5 cm or greater. Intervention for AAA includes conventional open surgical repair and endovascular aortic stent graft repair.

  17. Unenhanced low-dose versus standard-dose CT localization in patients with upper urinary calculi for minimally invasive percutaneous nephrolithotomy (MPCNL)

    PubMed Central

    Licheng, Jiang; Yidong, Fan; Ping, Wang; Keqiang, Yan; Xueting, Wang; Yingchen, Zhang; Lei, Gao; Jiyang, Ding; Zhonghua, Xu

    2014-01-01

    Background & objectives: With the ethical concern about the dose of CT scan and wide use of CT in protocol of suspected renal colic, more attention has been paid to low dose CT. The aim of the present study was to make a comparison of unenhanced low-dose spiral CT localization with unenhanced standard-dose spiral CT in patients with upper urinary tract calculi for minimally invasive percutaneous nephrolithotomy (MPCNL) treatment. Methods: Twenty eight patients with ureter and renal calculus, preparing to take MPCNL, underwent both abdominal low-dose CT (25 mAs) and standard-dose CT (100 mAs). Low-dose CT and standard-dose CT were independently evaluated for the characterization of renal/ureteral calculi, perirenal adjacent organs, blood vessels, indirect signs of renal or ureteral calculus (renal enlargement, pyeloureteral dilatation), and the indices of localization (percutaneous puncture angulation and depth) used in the MPCNL procedure. Results: In all 28 patients, low-dose CT was 100 per cent coincidence 100 per cent sensitive and 100 per cent specific for depicting the location of the renal and ureteral calculus, renal enlargement, pyeloureteral dilatation, adjacent organs, and the presumptive puncture point and a 96.3 per cent coincidence 96 per cent sensitivity and 93 per cent specificity for blood vessel signs within the renal sinus, and with an obvious lower radiation exposure for patients when compared to standard-dose CT (P<0.05). The indices of puncture depth, puncture angulation, and maximum calculus transverse diameter on the axial surface showed no significant difference between the two doses of CT scans, with a significant variation in calculus visualization slice numbers (P<0.05). Interpretation & conclusions: Our findings show that unenhanced low-dose CT achieves a sensitivity and accuracy similar to that of standard-dose CT in assessing the localization of renal ureteral calculus and adjacent organs conditions and identifying the maximum calculus transverse diameter on the axial surface, percutaneous puncture depth, and angulation in patients, with a significant lower radiation exposure, who are to be treated by MPCNL, and can be used as an alternative localization method. PMID:24820832

  18. Unenhanced low-dose versus standard-dose CT localization in patients with upper urinary calculi for minimally invasive percutaneous nephrolithotomy (MPCNL).

    PubMed

    Licheng, Jiang; Yidong, Fan; Ping, Wang; Keqiang, Yan; Xueting, Wang; Yingchen, Zhang; Lei, Gao; Jiyang, Ding; Zhonghua, Xu

    2014-03-01

    With the ethical concern about the dose of CT scan and wide use of CT in protocol of suspected renal colic, more attention has been paid to low dose CT. The aim of the present study was to make a comparison of unenhanced low-dose spiral CT localization with unenhanced standard-dose spiral CT in patients with upper urinary tract calculi for minimally invasive percutaneous nephrolithotomy (MPCNL) treatment. Twenty eight patients with ureter and renal calculus, preparing to take MPCNL, underwent both abdominal low-dose CT (25 mAs) and standard-dose CT (100 mAs). Low-dose CT and standard-dose CT were independently evaluated for the characterization of renal/ureteral calculi, perirenal adjacent organs, blood vessels, indirect signs of renal or ureteral calculus (renal enlargement, pyeloureteral dilatation), and the indices of localization (percutaneous puncture angulation and depth) used in the MPCNL procedure. In all 28 patients, low-dose CT was 100 per cent coincidence 100 per cent sensitive and 100 per cent specific for depicting the location of the renal and ureteral calculus, renal enlargement, pyeloureteral dilatation, adjacent organs, and the presumptive puncture point and a 96.3 per cent coincidence 96 per cent sensitivity and 93 per cent specificity for blood vessel signs within the renal sinus, and with an obvious lower radiation exposure for patients when compared to standard-dose CT (P<0.05). The indices of puncture depth, puncture angulation, and maximum calculus transverse diameter on the axial surface showed no significant difference between the two doses of CT scans, with a significant variation in calculus visualization slice numbers (P<0.05). Our findings show that unenhanced low-dose CT achieves a sensitivity and accuracy similar to that of standard-dose CT in assessing the localization of renal ureteral calculus and adjacent organs conditions and identifying the maximum calculus transverse diameter on the axial surface, percutaneous puncture depth, and angulation in patients, with a significant lower radiation exposure, who are to be treated by MPCNL, and can be used as an alternative localization method.

  19. Respiratory Displacement of the Thoracic Aorta: Physiological Phenomenon With Potential Implications for Thoracic Endovascular Repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weber, Tim Frederik, E-mail: tim.weber@med.uni-heidelberg.d; Tetzlaff, Ralf; Rengier, Fabian

    The purpose of this study was to assess the magnitude and direction of respiratory displacement of the ascending and descending thoracic aorta during breathing maneuvers. In 11 healthy nonsmokers, dynamic magnetic resonance imaging was performed in transverse orientation at the tracheal bifurcation during maximum expiration and inspiration as well as tidal breathing. The magnitude and direction of aortic displacement was determined relatively to resting respiratory position for the ascending (AA) and descending (DA) aorta. To estimate a respiratory threshold for occurrence of distinct respiratory aortic motion, the latter was related to the underlying change in anterior-posterior thorax diameter. Compound displacementmore » between maximum expiration and inspiration was 24.3 {+-} 6.0 mm for the AA in the left anterior direction and 18.2 {+-} 5.5 mm for the DA in the right anterior direction. The mean respiratory thorax excursion during tidal breathing was 8.9 {+-} 2.8 mm. The respiratory threshold, i.e., the increase in thorax diameter necessary to result in respiratory aortic displacement, was estimated to be 15.7 mm. The data suggest that after a threshold of respiratory thorax excursion is exceeded, respiration is accompanied by significant displacement of the thoracic aorta. Although this threshold may not be reached during tidal breathing in the majority of individuals, segmental differences during forced respiration impact on aortic geometry, may result in additional extrinsic forces on the aortic wall, and may be of significance for aortic prostheses designed for thoracic endovascular aortic repair.« less

  20. Microchip laser based on Yb:YAG/V:YAG monolith crystal

    NASA Astrophysics Data System (ADS)

    Nejezchleb, Karel; Šulc, Jan; Jelínková, Helena; Škoda, Václav

    2016-03-01

    V:YAG crystal was investigated as a passive Q-switch of longitudinally diode-pumped microchip laser, emitting radiation at wavelength 1030.5 nm. This laser was based on diffusion bonded monolith crystal (diameter 3 mm) which combines in one piece an active laser part (Yb:YAG crystal, 10 at.% Yb/Y, 3 mm long) and saturable absorber (V:YAG crystal, 2 mm long, initial transmission 86 % @ 1031 nm). The microchip resonator consisted of dielectric mirrors directly deposited on the monolith surfaces (pump mirror HT @ 968 nm and HR @ 1031 nm on Yb:YAG part, output coupler with reflection 55 % @ 1031 nm on the V:YAG part). For longitudinal CW pumping of Yb:YAG part, a fibre coupled (core diameter 100 μm, NA = 0.22, emission @ 968 nm) laser diode was used. The laser threshold was 3.8W. The laser slope efficiency for output mean in respect to incident pumping was 16 %. The linearly polarized generated transversal intensity beam profile was close to the fundamental Gaussian mode. The generated pulse length, stable and mostly independent on pumping power, was equal to 1.3 ns (FWHM). The single pulse energy was increasing with the pumping power and for the maximum pumping 9.7W it was 78 μJ which corresponds to the pulse peak-power 56 kW. The maximum Yb:YAG/V:YAG microchip laser mean output power of 1W was reached without observable thermal roll-over. The corresponding Q-switched pulses repetition rate was 13.1 kHz.

  1. Standardized 2D ultrasound versus 3D/4D ultrasound and image fusion for measurement of aortic aneurysm diameter in follow-up after EVAR.

    PubMed

    Pfister, Karin; Schierling, Wilma; Jung, Ernst Michael; Apfelbeck, Hanna; Hennersperger, Christoph; Kasprzak, Piotr M

    2016-01-01

    To compare standardised 2D ultrasound (US) to the novel ultrasonographic imaging techniques 3D/4D US and image fusion (combined real-time display of B mode and CT scan) for routine measurement of aortic diameter in follow-up after endovascular aortic aneurysm repair (EVAR). 300 measurements were performed on 20 patients after EVAR by one experienced sonographer (3rd degree of the German society of ultrasound (DEGUM)) with a high-end ultrasound machine and a convex probe (1-5 MHz). An internally standardized scanning protocol of the aortic aneurysm diameter in B mode used a so called leading-edge method. In summary, five different US methods (2D, 3D free-hand, magnetic field tracked 3D - Curefab™, 4D volume sweep, image fusion), each including contrast-enhanced ultrasound (CEUS), were used for measurement of the maximum aortic aneurysm diameter. Standardized 2D sonography was the defined reference standard for statistical analysis. CEUS was used for endoleak detection. Technical success was 100%. In augmented transverse imaging the mean aortic anteroposterior (AP) diameter was 4.0±1.3 cm for 2D US, 4.0±1.2 cm for 3D Curefab™, and 3.9±1.3 cm for 4D US and 4.0±1.2 for image fusion. The mean differences were below 1 mm (0.2-0.9 mm). Concerning estimation of aneurysm growth, agreement was found between 2D, 3D and 4D US in 19 of the 20 patients (95%). Definitive decision could always be made by image fusion. CEUS was combined with all methods and detected two out of the 20 patients (10%) with an endoleak type II. In one case, endoleak feeding arteries remained unclear with 2D CEUS but could be clearly localized by 3D CEUS and image fusion. Standardized 2D US allows adequate routine follow-up of maximum aortic aneurysm diameter after EVAR. Image Fusion enables a definitive statement about aneurysm growth without the need for new CT imaging by combining the postoperative CT scan with real-time B mode in a dual image display. 3D/4D CEUS and image fusion can improve endoleak characterization in selected cases but are not mandatory for routine practice.

  2. 49 CFR 571.10 - Designation of seating positions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... maximum width of a seating surface measured in a zone extending from a transverse vertical plane 150 mm (5.9 inches) behind the front leading surface of that seating surface to a transverse vertical plane... (5.5 inches), as measured in each transverse vertical plane within that measurement zone, or (B) A...

  3. The relationship between single and two-dimensional indices of left ventricular size using hemodynamic transesophageal echocardiography in trauma and burn patients.

    PubMed

    Younan, Duraid; Beasley, T Mark; Pigott, David C; Gibson, C Blayke; Gullett, John P; Richey, Jeffrey; Pittet, Jean-Francois; Zaky, Ahmed

    2017-10-11

    Conventional echocardiographic technique for assessment of volume status and cardiac contractility utilizes left ventricular end-diastolic area (LVEDA) and fractional area of change (FAC), respectively. Our goal was to find a technically reliable yet faster technique to evaluate volume status and contractility by measuring left ventricular end-diastolic diameter (LVEDD) and fractional shortening (FS) in a cohort of mechanically ventilated trauma and burn patients using hemodynamic transesophageal echocardiographic (hTEE) monitoring. Retrospective chart review performed at trauma/burn intensive care unit (TBICU). Data on 88 mechanically ventilated surgical intensive care patients cared for between July 2013 and July 2015 were reviewed. Initial measurements of LVEDA, left ventricular end-systolic area (LVESA) and FAC were collected. Post-processing left ventricular end-systolic (LVESD) and end-diastolic diameters (LVEDD) were measured and fractional shortening (FS) was calculated. Two orthogonal measurements of LV diameter were obtained in transverse (Tr) and posteroanterior (PA) orientation. There was a significant correlation between transverse and posteroanterior left ventricular diameter measurements in both systole and diastole. In systole, r = 0.92, p < 0.01 for LVESD-Tr (mean 23.47 mm, SD ± 6.77) and LVESD-PA (mean 24.84 mm, SD = 8.23). In diastole, r = 0.80, p < 0.01 for LVEDD-Tr (mean 37.60 mm, SD ± 6.45), and LVEDD-PA diameters (mean 42.24 mm, SD ± 7.97). Left ventricular area (LVEDA) also significantly correlated with left ventricular diameter LVEDD-Tr (r = 0.84, p < 0.01) and LVEDD-PA (r = 0.90, p < 0.01). Both transverse and PA measurements of fractional shortening were significantly (p < 0.0001) and similarly correlated with systolic function as measured by FAC. Bland-Altman analyses also indicated that the assessment of fractional shortening using left ventricular posteroanterior diameter measurement shows agreement with FAC. Left ventricular diameter measurements are a reliable and technically feasible alternative to left ventricular area measurements in the assessment of cardiac filling and systolic function.

  4. Parametric study of electromagnetic waves propagating in absorbing curved S ducts

    NASA Technical Reports Server (NTRS)

    Baumeister, Kenneth J.

    1989-01-01

    A finite-element Galerkin formulation has been developed to study attenuation of transverse magnetic (TM) waves propagating in two-dimensional S-curved ducts with absorbing walls. In the frequency range where the duct diameter and electromagnetic wave length are nearly equal, the effect of duct length, curvature (duct offset), and absorber wall thickness was examined. For a given offset in the curved duct, the length of the S-duct was found to significantly affect both the absorptive and reflective characteristics of the duct. For a straight and a curved duct with perfect electric conductor terminations, power attenuation contours were examined to determine electromagnetic wall properties associated with maximum input signal absorption. Offset of the S-duct was found to significantly affect the value of the wall permittivity associated with the optimal attenuation of the incident electromagnetic wave.

  5. Morphometric study of the lumbar spinal canal in the Korean population.

    PubMed

    Lee, H M; Kim, N H; Kim, H J; Chung, I H

    1995-08-01

    The anatomic dimensions of the vertebral body and spinal canal of the lumbar spine were analyzed in Koreans. To determine the normal dimension of the lumbar spinal canal in Koreans, to determine whether there are any racial differences in the morphometry of the lumbar spinal canal, and to provide criteria for diagnosing spinal stenosis in the Far Eastern Asian. Some radiologic and anatomic studies have been conducted regarding the size of the lumbar spinal canal of whites and blacks in western and African countries. One-thousand-eight-hundred measurements were performed on the transverse and sagittal diameters of vertebral bodies and spinal canals using complete sets of 90 lumbar vertebrae. The mean mid-sagittal diameter of the lumbar spinal canal in the Korean population was less than that measured in white and African populations, but there was no significant differences between the Korean, white, and African populations regarding the transverse diameter of the lumbar spinal canal. The mid-sagittal diameter of the lumbar spinal canal is narrowest in the Far Eastern Asian population; the radiologic criteria of spinal stenosis should be reconsidered for these people.

  6. Sexual dimorphism of the suprascapular notch – morphometric study

    PubMed Central

    Jędrzejewski, Kazimierz S.; Topol, Mirosław

    2013-01-01

    Introduction The concept of the study was to compare the morphometry of the suprascapular notch (SSN) in females and males because its size and shape may be a factor in suprascapular nerve entrapment. Material and methods The measurements of 81 scapulae included morphological length and width, maximal width and length projection of the scapular spine, and width and length of the glenoid cavity. The width-length scapular and glenoid cavity indices were calculated. In addition to standard anthropometric measurements three other dimensions were defined and collected for every SSN: maximal depth (MD), superior (STD) and middle (MTD) transverse diameters. Results The analysis of the measurements allowed us to distinguish five types of SSN. Type I (26%) had longer maximal depth than superior transverse diameter. Type II (3%) had equal MD, STD and MTD. In type III (57.6%) superior transverse diameter was longer than maximal depth. In type IV (7.4%) a bony foramen was present. Type V (6%) was without a discrete notch. Types I and III were divided into two subtypes: A (MTD was longer than STD) and B (MTD < STD). Distribution of the suprascapular notch types in both sexes was similar. However, MD, STD and MTD were significantly higher in males. The superior transverse suprascapular ligament was completely and partially ossified in 7.4% and 24.7% respectively. Conclusions The presented classification of the suprascapular notch is simple, easy to use, and based on specific geometric parameters which allow one to clearly distinguish five types of these structures. All dimensions of SSN were significantly higher in males than in females. PMID:23515320

  7. Comparison of radiographic and computed tomographic measurement of pedicle and vertebral body dimensions in Koreans: the ratio of pedicle transverse diameter to vertebral body transverse diameter.

    PubMed

    Kang, Ki Ser; Song, Kwang-Sup; Lee, Jong Seok; Yang, Jae Jun; Song, In Sup

    2011-03-01

    This study was designed to investigate the characteristics of pedicle transverse diameters (PD), vertebral body transverse diameters (VBD), especially the ratios of PD/VBD (CT ratio), which has never been discussed, in Koreans using computed tomography (CT) scans and to evaluate the possibility of obtaining more accurate estimations of PD from plain radiographs using the CT ratios in each spine level. The T1-L5 vertebrae of 50 participants were analyzed prospectively with CT scans (CT-VBD and CT-PD), and the T9-L5 vertebrae of the same participants were investigated with plain radiographs (X-VBD and X-PD). The CT ratio had a higher correlation with the CT-PD (r2 = 0.630) from T1 to L5, especially in the lower thoracic and lumbar spine (T9-L5, r2 = 0.737). The correlation of VBDs between the two radiologic tools (r2 = 0.896) was higher than that of the PDs (r2 = 0.665). Based on the data, equations for the estimation of a more accurate PD from plain radiographs were developed as follows: estimated PD = estimated VBD × [1.014 × (X-VBD) + 0.152] × the mean CT ratio at each spinal level. The correlation between the estimated PD and the CT-PD (r2 = 0.852) was improved compared with that (r2 = 0.665) between the X-PD and the CT-PD. In conclusion, the CT ratio showed a very similar changing trends to CT-PD from T1 to L5 regardless of sex and body mass, and the measurement error of PD from only plain radiographs could be minimized using estimated VBD and the mean CT ratio at each spinal level.

  8. Application of small-diameter FBG sensors for detection of damages in composites

    NASA Astrophysics Data System (ADS)

    Okabe, Yoji; Mizutani, Tadahito; Yashiro, Shigeki; Takeda, Nobuo

    2001-08-01

    Small-diameter fiber Bragg grating (FBG) sensors have been developed by Hitachi Cable Ltd. and the authors. Since the outside diameter of polyimide coating is 52 micrometers , embedding of the sensors into carbon fiber reinforced plastic (CFRP) composites prepregs of 125 micrometers in thickness does not deteriorate the mechanical properties of the composite laminates. In this research, the small-diameter FBG sensor was applied for the detection of transverse cracks in CFRP composites. The FBG sensor was embedded in 0 degree(s) ply of a CFRP cross-ply laminate.

  9. Tensile properties of the transverse carpal ligament and carpal tunnel complex.

    PubMed

    Ugbolue, Ukadike C; Gislason, Magnus K; Carter, Mark; Fogg, Quentin A; Riches, Philip E; Rowe, Philip J

    2015-08-01

    A new sophisticated method that uses video analysis techniques together with a Maillon Rapide Delta to determine the tensile properties of the transverse carpal ligament-carpal tunnel complex has been developed. Six embalmed cadaveric specimens amputated at the mid-forearm and aged (mean (SD)): 82 (6.29) years were tested. The six hands were from three males (four hands) and one female (two hands). Using trigonometry and geometry the elongation and strain of the transverse carpal ligament and carpal arch were calculated. The cross-sectional area of the transverse carpal ligament was determined. Tensile properties of the transverse carpal ligament-carpal tunnel complex and Load-Displacement data were also obtained. Descriptive statistics, one-way ANOVA together with a post-hoc analysis (Tukey) and t-tests were incorporated. A transverse carpal ligament-carpal tunnel complex novel testing method has been developed. The results suggest that there were no significant differences between the original transverse carpal ligament width and transverse carpal ligament at peak elongation (P=0.108). There were significant differences between the original carpal arch width and carpal arch width at peak elongation (P=0.002). The transverse carpal ligament failed either at the mid-substance or at their bony attachments. At maximum deformation the peak load and maximum transverse carpal ligament displacements ranged from 285.74N to 1369.66N and 7.09mm to 18.55mm respectively. The transverse carpal ligament cross-sectional area mean (SD) was 27.21 (3.41)mm(2). Using this method the results provide useful biomechanical information and data about the tensile properties of the transverse carpal ligament-carpal tunnel complex. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. In Utero Exposure to Di( n-butyl)phthalate Induces Morphological and Biochemical Changes in Rats Postpuberty.

    PubMed

    Okayama, Yuya; Wakui, Shin; Wempe, Michael F; Sugiyama, Mitsuru; Motohashi, Masaya; Mutou, Tomoko; Takahashi, Hiroyuki; Kume, Eisuke; Ikegami, Hiroshi

    2017-06-01

    Pregnant Sprague-Dawley rats were orally administered di( n-butyl)phthalate (DBP; 100 mg/kg/day) on gestation days (GD) 12 to 21. We investigated the male offspring and probed morphological alterations in Sertoli cells at 7, 9, 14, and 17 weeks of age. Parameters assessed in this study included offspring number, sex ratios, body weights, testis weights, seminiferous tubule (ST) profile numbers and diameters, number of vimentin-labeled Sertoli cells, and both testosterone and follicle-stimulating hormone (FSH) levels. Testicular weight/body weight ratios and the numbers and diameters of ST in maximum transverse testicular sections were statistically similar at weeks 7 and 9; however, at weeks 14 and 17, they were statistically different and displayed higher BrdU-positive Sertoli cells/Sertoli cell ratios in the DBP treatment group. Noteworthily, the serum FSH levels were higher and testicular testosterone levels were lower in the DBP treatment group. To our knowledge, the present study is the first to report that in utero DBP exposure significantly increased Sertoli cell numbers and their cellular proliferation from postpuberty to adulthood, with a significant decrease in testicular testosterone and an increase in FSH.

  11. Inspection of anode and field wires for the COMPASS drift chamber, DC5, with Environmental Scanning Electron Microscope

    NASA Astrophysics Data System (ADS)

    Cyuzuzo, Sonia

    2014-09-01

    The COMPASS experiment at CERN uses a secondary pion beam from the Super Proton Synchrotron (SPS) at CERN to explore the spin structure of nucleons. A new drift chamber, DC5, will be integrated into the COMPASS spectrometer to replace an aging straw tube detector. DC5 will detect muon pairs from Drell-Yan scattering of a pion-beam off a transversely polarized proton target. This data will be used to determine the correlation between transverse proton spin and the intrinsic transverse momentum of up-quarks inside the proton, the Sivers effect. DC5 is a large area planar drift chamber with 8 layers of anode-frames made of G10 fiberglass-epoxy. The G10 frames support printed circuit boards for soldering 20 μm diameter anode and 100 μm diameter field wires. The anode planes are sandwiched by 13 graphite coated Mylar cathode planes. To ensure a well-functioning of DC5, the wires were carefully tested. An optical inspection and a spectral analysis was performed with an Environmental Scanning Electron Microscope (ESEM) to verify the composition and dimensions and the integrity of the gold plating on the surface of these wires. The spectra of the wires were studied at 10 and 30 keV. The COMPASS experiment at CERN uses a secondary pion beam from the Super Proton Synchrotron (SPS) at CERN to explore the spin structure of nucleons. A new drift chamber, DC5, will be integrated into the COMPASS spectrometer to replace an aging straw tube detector. DC5 will detect muon pairs from Drell-Yan scattering of a pion-beam off a transversely polarized proton target. This data will be used to determine the correlation between transverse proton spin and the intrinsic transverse momentum of up-quarks inside the proton, the Sivers effect. DC5 is a large area planar drift chamber with 8 layers of anode-frames made of G10 fiberglass-epoxy. The G10 frames support printed circuit boards for soldering 20 μm diameter anode and 100 μm diameter field wires. The anode planes are sandwiched by 13 graphite coated Mylar cathode planes. To ensure a well-functioning of DC5, the wires were carefully tested. An optical inspection and a spectral analysis was performed with an Environmental Scanning Electron Microscope (ESEM) to verify the composition and dimensions and the integrity of the gold plating on the surface of these wires. The spectra of the wires were studied at 10 and 30 keV. Acknowledging NSF and UIUC.

  12. Terawatt x-ray free-electron-laser optimization by transverse electron distribution shaping

    DOE PAGES

    Emma, C.; Wu, J.; Fang, K.; ...

    2014-11-03

    We study the dependence of the peak power of a 1.5 Å Terawatt (TW), tapered x-ray free-electron laser (FEL) on the transverse electron density distribution. Multidimensional optimization schemes for TW hard x-ray free-electron lasers are applied to the cases of transversely uniform and parabolic electron beam distributions and compared to a Gaussian distribution. The optimizations are performed for a 200 m undulator and a resonant wavelength of λ r = 1.5 Å using the fully three-dimensional FEL particle code GENESIS. The study shows that the flatter transverse electron distributions enhance optical guiding in the tapered section of the undulator andmore » increase the maximum radiation power from a maximum of 1.56 TW for a transversely Gaussian beam to 2.26 TW for the parabolic case and 2.63 TW for the uniform case. Spectral data also shows a 30%–70% reduction in energy deposited in the sidebands for the uniform and parabolic beams compared with a Gaussian. An analysis of the transverse coherence of the radiation shows the coherence area to be much larger than the beam spotsize for all three distributions, making coherent diffraction imaging experiments possible.« less

  13. Influence of bronchial diameter change on the airflow dynamics based on a pressure-controlled ventilation system.

    PubMed

    Ren, Shuai; Cai, Maolin; Shi, Yan; Xu, Weiqing; Zhang, Xiaohua Douglas

    2018-03-01

    Bronchial diameter is a key parameter that affects the respiratory treatment of mechanically ventilated patients. In this paper, to reveal the influence of bronchial diameter on the airflow dynamics of pressure-controlled mechanically ventilated patients, a new respiratory system model is presented that combines multigeneration airways with lungs. Furthermore, experiments and simulation studies to verify the model are performed. Finally, through the simulation study, it can be determined that in airway generations 2 to 7, when the diameter is reduced to half of the original value, the maximum air pressure (maximum air pressure in lungs) decreases by nearly 16%, the maximum flow decreases by nearly 30%, and the total airway pressure loss (sum of each generation pressure drop) is more than 5 times the original value. Moreover, in airway generations 8 to 16, with increasing diameter, the maximum air pressure, maximum flow, and total airway pressure loss remain almost constant. When the diameter is reduced to half of the original value, the maximum air pressure decreases by 3%, the maximum flow decreases by nearly 5%, and the total airway pressure loss increases by 200%. The study creates a foundation for improvement in respiratory disease diagnosis and treatment. Copyright © 2017 John Wiley & Sons, Ltd.

  14. High-frequency ultrasonic wire bonding systems

    PubMed

    Tsujino; Yoshihara; Sano; Ihara

    2000-03-01

    The vibration characteristics of longitudinal-complex transverse vibration systems with multiple resonance frequencies of 350-980 kHz for ultrasonic wire bonding of IC, LSI or electronic devices were studied. The complex vibration systems can be applied for direct welding of semiconductor tips (face-down bonding, flip-chip bonding) and packaging of electronic devices. A longitudinal-complex transverse vibration bonding system consists of a complex transverse vibration rod, two driving longitudinal transducers 7.0 mm in diameter and a transverse vibration welding tip. The vibration distributions along ceramic and stainless-steel welding tips were measured at up to 980 kHz. A high-frequency vibration system with a height of 20.7 mm and a weight of less than 15 g was obtained.

  15. Computed tomographic characteristics of the cisterna chyli in dogs.

    PubMed

    Birch, Sally; Barberet, Virginie; Bradley, Kate; Parsons, Kevin; Warren-Smith, Christopher

    2014-01-01

    Previous lymphangiographic studies have investigated the use of computed tomography (CT) for characterizing the thoracic duct and its tributaries in dogs. However, there is limited published information on the appearance of the canine cisterna chyli using CT. The objective of this retrospective study was to describe the features of the canine cisterna chyli in pre- and post-contrast abdominal CT studies. The presence, location, shape, maximum width, size compared with the aortic diameter (Ao:cisterna chyli ratio) and mean attenuation of the cisterna chyli were recorded from archived abdominal CT scans of 30 dogs. Breed, age, sex and neutering status were also noted. A cisterna chyli was identified in 26 of the dogs (87%). In 22 cases a cisterna chyli could be reliably identified prior to intravenous contrast administration and in all 26 cases in postcontrast images. The cisterna chyli was most commonly located right dorsolateral to the abdominal aorta between L1 and L4. Shape varied on transverse images from crescent-like to globular and maximum diameters ranged from 5 to 9 mm. The Ao:cisterna chyli ratio varied between 0.29 and 0.71 (mean value-males: 0.32; females: 0.38). On pre-contrast images the mean Hounsfield units were 21.3HU (range: -3.8 to 64.25). Mild enhancement of the cisterna chyli post-contrast was observed in 24 dogs (80%). Findings supported the use of pre- and post-contrast abdominal CT as a non-invasive method for assessing qualitative and quantitative characteristics of the canine cisterna chyli. © 2013 American College of Veterinary Radiology.

  16. Generation and confinement of microwave gas-plasma in photonic dielectric microstructure.

    PubMed

    Debord, B; Jamier, R; Gérôme, F; Leroy, O; Boisse-Laporte, C; Leprince, P; Alves, L L; Benabid, F

    2013-10-21

    We report on a self-guided microwave surface-wave induced generation of ~60 μm diameter and 6 cm-long column of argon-plasma confined in the core of a hollow-core photonic crystal fiber. At gas pressure of 1 mbar, the micro-confined plasma exhibits a stable transverse profile with a maximum gas-temperature as high as 1300 ± 200 K, and a wall-temperature as low as 500 K, and an electron density level of 10¹⁴ cm⁻³. The fiber guided fluorescence emission presents strong Ar⁺ spectral lines in the visible and near UV. Theory shows that the observed combination of relatively low wall-temperature and high ionisation rate in this strongly confined configuration is due to an unprecedentedly wide electrostatic space-charge field and the subsequent ion acceleration dominance in the plasma-to-gas power transfer.

  17. Design of Tools for Press-countersinking or Dimpling 0.040-inch-thick-24S-T Sheet

    NASA Technical Reports Server (NTRS)

    Templin, R L; Fogwell, J W

    1942-01-01

    A set of dimpling tools was designed for 0.040-inch 24S-T sheet and flush-type rivets 1/8 inch in diameter with 100 degree countersunk heads. The dimples produced under different conditions of pressure, sheet thickness, and drill diameter are presented as cross-sectional photographs magnified 20 times. The most satisfactory values for the dimpling tools were found to be: maximum punch diameter, 0.231 inch; maximum die diameter, 0.223 inch; maximum mandrel diameter, 0.128 inch; dimple angle, 100 degree; punch springback angle, 1 1/2 degree; and die springback angle, 2 degree.

  18. Imaging Characteristics of Pathologically Proven Thymic Hyperplasia: Identifying Features That Can Differentiate True From Lymphoid Hyperplasia

    PubMed Central

    Araki, Tetsuro; Sholl, Lynette M.; Gerbaudo, Victor H.; Hatabu, Hiroto; Nishino, Mizuki

    2014-01-01

    OBJECTIVE The purpose of this article is to investigate the imaging characteristics of pathologically proven thymic hyperplasia and to identify features that can differentiate true hyperplasia from lymphoid hyperplasia. MATERIALS AND METHODS Thirty-one patients (nine men and 22 women; age range, 20–68 years) with pathologically confirmed thymic hyperplasia (18 true and 13 lymphoid) who underwent preoperative CT (n = 27), PET/CT (n = 5), or MRI (n = 6) were studied. The length and thickness of each thymic lobe and the transverse and anterior-posterior diameters and attenuation of the thymus were measured on CT. Thymic morphologic features and heterogeneity on CT and chemical shift on MRI were evaluated. Maximum standardized uptake values were measured on PET. Imaging features between true and lymphoid hyperplasia were compared. RESULTS No significant differences were observed between true and lymphoid hyperplasia in terms of thymic length, thickness, diameters, morphologic features, and other qualitative features (p > 0.16). The length, thickness, and diameters of thymic hyperplasia were significantly larger than the mean values of normal glands in the corresponding age group (p < 0.001). CT attenuation of lymphoid hyperplasia was significantly higher than that of true hyperplasia among 15 patients with contrast-enhanced CT (median, 47.9 vs 31.4 HU; Wilcoxon p = 0.03). The receiver operating characteristic analysis yielded greater than 41.2 HU as the optimal threshold for differentiating lymphoid hyperplasia from true hyperplasia, with 83% sensitivity and 89% specificity. A decrease of signal intensity on opposed-phase images was present in all four cases with in- and opposed-phase imaging. The mean maximum standardized uptake value was 2.66. CONCLUSION CT attenuation of the thymus was significantly higher in lymphoid hyperplasia than in true hyperplasia, with an optimal threshold of greater than 41.2 HU in this cohort of patients with pathologically confirmed thymic hyperplasia. PMID:24555583

  19. Magnetic interactions and reversal mechanisms in Co nanowire and nanotube arrays

    NASA Astrophysics Data System (ADS)

    Proenca, M. P.; Sousa, C. T.; Escrig, J.; Ventura, J.; Vazquez, M.; Araujo, J. P.

    2013-03-01

    Ordered hexagonal arrays of Co nanowires (NWs) and nanotubes (NTs), with diameters between 40 and 65 nm, were prepared by potentiostatic electrodeposition into suitably modified nanoporous alumina templates. The geometrical parameters of the NW/NT arrays were tuned by the pore etching process and deposition conditions. The magnetic interactions between NWs/NTs with different diameters were studied using first-order reversal curves (FORCs). From a quantitative analysis of the FORC measurements, we are able to obtain the profiles of the magnetic interactions and the coercive field distributions. In both NW and NT arrays, the magnetic interactions were found to increase with the diameter of the NWs/NTs, exhibiting higher values for NW arrays. A comparative study of the magnetization reversal processes was also performed by analyzing the angular dependence of the coercivity and correlating the experimental data with theoretical calculations based on a simple analytical model. The magnetization in the NW arrays is found to reverse by the nucleation and propagation of a transverse-like domain wall; on the other hand, for the NT arrays a non-monotonic behavior occurs above a diameter of ˜50 nm, revealing a transition between the vortex and transverse reversal modes.

  20. Transsacral Osseous Corridor Anatomy Is More Amenable To Screw Insertion In Males: A Biomorphometric Analysis of 280 Pelves.

    PubMed

    Gras, Florian; Gottschling, Heiko; Schröder, Manuel; Marintschev, Ivan; Hofmann, Gunther O; Burgkart, Rainer

    2016-10-01

    Percutaneous iliosacral screw placement is the standard procedure for fixation of posterior pelvic ring lesions, although a transsacral screw path is being used more frequently in recent years owing to increased fracture-fixation strength and better ability to fix central and bilateral sacral fractures. However, biomorphometric data for the osseous corridors are limited. Because placement of these screws in a safe and effective manner is crucial to using transsacral screws, we sought to address precise sacral anatomy in more detail to look for anatomic variation in the general population. We asked: (1) What proportion of healthy pelvis specimens have no transsacral corridor at the level of the S1 vertebra owing to sacral dysmorphism? (2) If there is no safe diameter for screw placement in the transsacral S1 corridor, is an increased and thus safe diameter of the transsacral S2 corridor expected? (3) Are there sex-specific differences in sacral anatomy and are these correlated with known anthropometric parameters? CT scans of pelves of 280 healthy patients acquired exclusively for medical indications such as polytrauma (20%), CT angiography (70%), and other reasons (10%), were segmented manually. Using an advanced CT-based image analysis system, the mean shape of all segmented pelves was generated and functioned as a template. On this template, the cylindric transsacral osseous corridor at the level of the S1 and S2 vertebrae was determined manually. Each pelvis then was registered to the template using a free-form registration algorithm to measure the maximum screw corridor diameters on each specimen semiautomatically. Thirty of 280 pelves (11%) had no transsacral S1 corridor owing to sacral dysmorphism. The average of maximum cylindrical diameters of the S1 corridor for the remaining 250 pelves was 12.8 mm (95% CI, 12.1-13.5 mm). A transverse corridor for S2 was found in 279 of 280 pelves, with an average of maximum cylindrical diameter of 11.6 mm (95% CI, 11.3-11.9 mm). Decreasing transsacral S1 corridor diameters are correlated with increasing transsacral S2 corridor diameters (R value for females, -0.260, p < 0.01; for males, -0.311, p < 0.001). Female specimens were more likely to have sacral dysmorphism (defined as a pelvis without a transsacral osseous corridor at the level of the S1 vertebra) than were male specimens (females, 16%; males, 7%; p < 0.003). Furthermore female pelves had smaller-corridor diameters than did male pelves (females versus males for S1: 11.7 mm [95% CI, 10.6-12.8 mm] versus 13.5 mm [95% CI, 12.6-14.4 mm], p < 0.01; and for S2: 10.6 mm [95% CI, 10.1-11.1 mm] versus 12.2 mm [95% CI, 11.8-12.6 mm ], p < 0.0001). Narrow corridors and highly individual, sex-dependent variance of morphologic features of the sacrum make transsacral implant placement technically demanding. Individual preoperative axial-slice CT scan analyses and orthogonal coronal and sagittal reformations are recommended to determine the prevalence of sufficient-sized osseous corridors on both levels for safe screw placements, especially in female patients, owing to their smaller corridor diameters and higher rate of sacral dysmorphism.

  1. Passively stabilized 215-W monolithic CW LMA-fiber laser with innovative transversal mode filter

    NASA Astrophysics Data System (ADS)

    Stutzki, Fabian; Jauregui, Cesar; Voigtländer, Christian; Thomas, Jens U.; Limpert, Jens; Nolte, Stefan; Tünnermann, Andreas

    2010-02-01

    We report on the development of a high power monolithic CW fiber oscillator with an output power of 215 W in a 20μm core diameter few-mode Large Mode Area fiber (LMA). The key parameters for stable operation are reviewed. With these optimizations the root mean square of the output power fluctuations can be reduced to less than 0.5 % on a timescale of 20 s, which represents an improvement of more than a factor 5 over a non-optimized fiber laser. With a real-time measurement of the mode content of the fiber laser it can be shown that the few-mode nature of LMA fibers is the main factor for the residual instability of our optimized fiber laser. The root of the problem is that Fiber Bragg Gratings (FBGs) written in multimode fibers exhibit a multi-peak reflexion spectrum in which each resonance corresponds to a different transversal mode. This reflectivity spectrum stimulates multimode laser operation, which results in power and pointing instabilities due to gain competition between the different transversal modes . To stabilize the temporal and spatial behavior of the laser output, we propose an innovative passive in-fiber transversal mode filter based on modified FBG-Fabry Perot structure. This structure provides different reflectivities to the different transversal modes according to the transversal distribution of their intensity profile. Furthermore, this structure can be completely written into the active fiber using fs-laser pulses. Moreover, this concept scales very well with the fiber core diameter, which implies that there is no performance loss in fibers with even larger cores. In consequence this structure is inherently power scalable and can, therefore, be used in kW-level fiber laser systems.

  2. Preoperative tumor size at MRI predicts deep myometrial invasion, lymph node metastases, and patient outcome in endometrial carcinomas.

    PubMed

    Ytre-Hauge, Sigmund; Husby, Jenny A; Magnussen, Inger J; Werner, Henrica M J; Salvesen, Øyvind O; Bjørge, Line; Trovik, Jone; Stefansson, Ingunn M; Salvesen, Helga B; Haldorsen, Ingfrid S

    2015-03-01

    The aim of this study was to explore the relation between preoperative tumor size based on magnetic resonance imaging (MRI) and the surgical pathologic staging parameters (deep myometrial invasion, cervical stroma invasion, and metastatic lymph nodes) and to assess the prognostic impact of tumor size in endometrial carcinomas. Interobserver variability for the different tumor size measurements was also assessed. Preoperative pelvic MRI of 212 patients with histologically confirmed endometrial carcinomas was read independently by 3 radiologists. Maximum tumor diameters were measured in 3 orthogonal planes (anteroposterior, transverse, and craniocaudal planes [CC]), and tumor volumes were estimated. Tumor size was analyzed in relation to surgical staging results and patient survival. The multivariate analyses were adjusted for preoperative risk status based on endometrial biopsy. Intraclass correlation coefficients and receiver operating characteristics curves for the different tumor measurements were also calculated. Anteroposterior tumor diameter independently predicted deep myometrial invasion (P < 0.001), whereas CC tumor diameter tended to independently predict lymph node metastases (P = 0.06). Based on receiver operating characteristic curves, the following tumor size cutoff values were identified: anteroposterior diameter greater than 2 cm predicted deep myometrial invasion (unadjusted odds ratio [OR], 12.4; P < 0.001; adjusted OR, 6.7; P < 0.001) and CC diameter greater than 4 cm predicted lymph node metastases (unadjusted OR, 6.2; P < 0.001; adjusted OR, 4.9; P = 0.009). Large tumor size was associated with reduced progression/recurrence-free survival (P ≤ 0.005 for all size parameters), and CC diameter had an independent impact on survival (adjusted hazards ratio, 1.04; P = 0.009). The interobserver variability for the different size measurements was very low (intraclass correlation coefficient, 0.78-0.85). Anteroposterior tumor diameter greater than 2 cm predicts deep myometrial invasion, and CC tumor diameter greater than 4 cm predicts lymph node metastases. Tumor size is a strong prognostic factor in endometrial carcinomas. Preoperative tumor measurements based on MRI may potentially improve preoperative risk stratification models and thus enable better tailored surgical treatment in endometrial cancer.

  3. The temperature of unheated bodies in a high-speed gas stream

    NASA Technical Reports Server (NTRS)

    Eckert, E; Weise, W

    1941-01-01

    The present report deals with temperature measurements on cylinders of 0.2 to 3 millimeters diameter in longitudinal and transverse air flow at speeds of 100 to 300 meters per second. Within the explored test range, that is, the probable laminar boundary layer region, the temperature of the cylinders in axial flow is practically independent of the speed and in good agreement with Pohlhausen's theoretical values; Whereas, in transverse flow, cylinders of certain diameter manifest a close relationship with speed, the ratio of the temperature above the air of the body to the adiabatic stagnation temperature decreases with rising speed and then rises again from a Mach number of 0.6. The importance of this "specific temperature" of the body for heat-transfer studies at high speed is discussed.

  4. Research on filling scheme and deformation properties of wide subgrade of foamed lightweight soil on soft ground

    NASA Astrophysics Data System (ADS)

    Zhang, Faru; Yang, Deguang; Zhang, Liujun

    2018-01-01

    The wide subgrade on soft soil ground has the significantly different transverse settlement curve characteristics and the lacation of the maximum asymmetrical transverse settlement compared with ordinary subgrade. Especially when the subgrade filled with materials of different densities, the synergism deformation of ground-subgrade-pavement and the pavement structure stress become more complex. Combining with the engineering example, the settlement deformation characteristics of wide subgrade adopting the different filling scheme and the stress distribution of pavement structure are analyzed. Results show that the settlement curve of wide subgrade has a shape of flat middle with steep sides, and the maximum transverse asymmetrical settlement locates in close to the shoulder position. The maximum stress within the pavement structure is also in close to the shoulder position. Regarding the wide subgrade composed of main road and relief road, the post-construction settlement can be greatly reduced when both roads are filled with foamed lightweight soil.

  5. Nondestructive Evaluation of Young's Moduli of Full-Size wood Laminated Composite Poles

    Treesearch

    Cheng Piao; Todd F. Shube; Chung Y. Hse; R.C. Tang

    2004-01-01

    An exploratory study was conducted to evaluate the Young's moduli of wood laminated composite poles (LCP) by using a free transverse vibration method. Full-size LCP, 6.1 m long and 10.2 cm in diameter, were lab-fabricated with 9 and/or 12 southern yellow pine [SYP] strips of thickness, 1.9 cm, 2.9 cm and 3.8 cm. The frequency of free transverse vibration in a LCP...

  6. Assessment and Evaluation of Anatomic Variations of Retromolar Pad: A Cross Sectional Study

    PubMed Central

    Deep, Anchal; Siwach, Amit; Singh, Manas; Bhargava, Akshay; Siwach, Reenu

    2016-01-01

    Introduction The retromolar pad also called piriformis papilla is a mucosal elevation located in the retromolar area covering the retromolar triangle. After molar loss, the bony alveolar process and surrounding soft periodontal tissue remodel, mainly resorb and blend with retromolar pad. It is a key intraoral landmark in prosthodontics. Aim The aim of this in-vitro study was to analyze the various anatomical shapes and sizes of retromolar pad in 150 completely edentulous patients between 55 to 70 years of age group. Materials and Methods The study was conducted on 150 completely edentulous patients. The shapes of retromolar pad on the left and right side were seen and divided into pear, triangular and round shape. The comparison of the mean longitudinal diameter and transverse diameter on the right and left sides was done. The data was evaluated statistically. The chi-square test was used for the comparison between the proportions with the help of standard deviation, t-test was used for comparison between the left and the right side and ANOVA test was used for comparison between the various shapes of the retromolar pads. Results The result showed that there was statistically significant difference among different shapes of retromolar pad and there was significant difference in mean transverse and longitudinal diameter on right and left side, the mean value of the longitudinal diameter on left and right side was 8.81 and 8.69 whereas the mean value of the transverse diameter on left and right side was 6.79 and 6.82 respectively and p-value obtained for both was 0.550 and 0.814 respectively. Conclusion The study conclude that there are three different shapes of retromolar pad among which pear and triangular shaped retomolar pad provides more stability in lower denture because of increase surface area. PMID:27437350

  7. Morphometric analysis of diameter and relationship of vertebral artery with respect to transverse foramen in Indian population

    PubMed Central

    Sureka, Binit; Mittal, Mahesh Kumar; Mittal, Aliza; Agarwal, Mukul Sinha Kanhaiya; Bhambri, Narendra Kumar; Thukral, Brij Bhushan

    2015-01-01

    Purpose: To study the location, origin, size and relationship of the vertebral artery and the transverse foramina in the lower cervical spine by computed tomographic angiography (CTA) measurements in the Indian population. Materials and Methods: A retrospective review of multi-detector CT (MDCT) cerebral angiography scans was done between June 2011 and February 2014. A total of 120 patients were evaluated. The diameter of the vertebral artery (AL) and the shortest distance between the vertebral artery and the medial (M), lateral (L), anterior (A), and posterior (P) borders of transverse foramen were studied. In addition, the shortest distance between the vertebral artery and pedicle (h) was also analyzed. Statistical Analysis: The means and their standard deviations (SD) were calculated in both the sexes. The t-tests were performed to look for significant sexual difference. Results: The largest vertebral artery diameter (AL) was at level C7 on the right side (3.5 ± 0.8) and at the level of C5 on the left side (3.7 ± 0.4). Statistically significant difference between males and females were seen at levels C4, C5, and C7. The diameter of the vertebral artery was smaller in females than males. The L value was greater than other parameters (M, A, P) at the same level in all the measurements. The h value was greatest at C6 level and shortest at C5. Conclusion: CTA is necessary before pedicle screw fixation due to variation in measurements at all levels. The highest potential risk of vertebral artery injury during cervical pedicle screw implantation may be at C5, then at C4, and the safest is at C7. PMID:25969640

  8. A high repetition rate passively Q-switched microchip laser for controllable transverse laser modes

    NASA Astrophysics Data System (ADS)

    Dong, Jun; Bai, Sheng-Chuang; Liu, Sheng-Hui; Ueda, Ken-Ichi; Kaminskii, Alexander A.

    2016-05-01

    A Cr4+:YAG passively Q-switched Nd:YVO4 microchip laser for versatile controllable transverse laser modes has been demonstrated by adjusting the position of the Nd:YVO4 crystal along the tilted pump beam direction. The pump beam diameter-dependent asymmetric saturated inversion population inside the Nd:YVO4 crystal governs the oscillation of various Laguerre-Gaussian, Ince-Gaussian and Hermite-Gaussian modes. Controllable transverse laser modes with repetition rates over 25 kHz and up to 183 kHz, depending on the position of the Nd:YVO4 crystal, have been achieved. The controllable transverse laser beams with a nanosecond pulse width and peak power over hundreds of watts have been obtained for potential applications in optical trapping and quantum computation.

  9. Characterizing Detonating LX-17 Charges Crossing a Transverse Air Gap with Experiments and Modeling

    NASA Astrophysics Data System (ADS)

    Lauderbach, Lisa M.; Souers, P. Clark; Garcia, Frank; Vitello, Peter; Vandersall, Kevin S.

    2009-12-01

    Experiments were performed using detonating LX-17 (92.5% TATB, 7.5% Kel-F by weight) charges with various width transverse air gaps with manganin peizoresistive in-situ gauges present. The experiments, performed with 25 mm diameter by 25 mm long LX-17 pellets with the transverse air gap in between, showed that transverse gaps up to about 3 mm could be present without causing the detonation wave to fail to continue as a detonation. The Tarantula/JWL++ code was utilized to model the results and compare with the in-situ gauge records with some agreement to the experimental data with additional work needed for a better match to the data. This work will present the experimental details as well as comparison to the model results.

  10. Wood density and anatomical properties in suppressed-growth trees : comparison of two methods

    Treesearch

    David W. Vahey; J. Y. Zhu; C. Tim Scott

    2007-01-01

    Interest in the commercial value of small-diameter timber has led to testing core samples with SilviScan to characterize density and transverse fiber dimensions. Data showed that latewood density and tracheid diameter in suppressed-growth material can vary spatially on a scale comparable to the 50-_m resolution of the instrument used in our testing. An optical imaging...

  11. Sex estimation by femur in modern Thai population.

    PubMed

    Monum, T; Prasitwattanseree, S; Das, S; Siriphimolwat, P; Mahakkanukrauh, P

    2017-01-01

    Sex estimation is an important step of postmortem investigation and the femur is a useful bone for sex estimation by using metric analysis method. Even though there have been a reported sex estimation method by using femur in Thais, the temporal change related to time and anthropological data need to be renewed. Thus the aim of this study is to re-evaluate sex estimation by femur in Thais. 97 adult male and 103 female femora were random chosen from Forensic osteology research center and 6 measurements were applied tend to. To compare with previous Thai data, mid shaft diameter to increase but femoral head and epicondylar breadth to stabilize and when tested previous discriminant function by vertical head diameter and epicondalar breadth, the accuracy of prediction was lower than previous report. From the new data, epicondalar breadth is the best variable for distinguishing male and female at 88.7 percent of accuracy, following by transverse and vertical head diameter at 86.7 percent and femoral neck diameter at 81.7 percent of accuracy. Multivariate discriminant analysis indicated transverse head diameter and epicondylar breadth performed highest rate of accuracy at 89.7 percent. The percent of accuracy of femur was close to previous reported sex estimation by talus and calcaneus in Thai population. Thus, for especially in case of lower limb remain, which absence of pelvis.

  12. Is endoscopic papillary large balloon dilation safe for treating large CBD stones?

    PubMed

    Shim, Chan Sup; Kim, Ji Wan; Lee, Tae Yoon; Cheon, Young Koog

    2016-01-01

    In recent years, endoscopic papillary large balloon dilation (EPLBD) with endoscopic sphincterotomy (EST) has been shown to be an effective technique for the removal of large or difficult common bile duct (CBD) stones, as an alternative to EST. Reviewing the literature published since 2003, it is understood that EPLBD has fewer associated overall complications than EST. Bleeding occurred less frequently with EPLBD than with EST. There was no significant difference in postendoscopic retrograde cholangiopancreatography pancreatitis or perforation. Recent accumulated results of EPLBD with or even without EST suggest that it is a safe and effective procedure for the removal of large or difficult bile duct stones without any additional risk of severe adverse events, when performed under appropriate guidelines. Since use of a larger balloon can tear the sphincter as well as the bile duct, possibly resulting in bleeding and perforation, a balloon size that is equal to or smaller in diameter than the diameter of the native distal bile duct is recommended. The maximum transverse diameter of the stone and the balloon-stone diameter ratio have a tendency to affect the success or failure of complete removal of stones by large balloon dilation to prevent adverse effects such as perforation and bleeding. One should take into account the size of the native bile duct, the size and burden of stones, the presence of stricture of distal bile duct, and the presence of the papilla in or adjacent to a diverticulum. Even though the results of EPLBD indicate that it is a relatively safe procedure in patients with common duct stones with a dilated CBD, the recommended guidelines should be followed strictly for the prevention of major adverse events such as bleeding and perforation.

  13. Validating automated kidney stone volumetry in computed tomography and mathematical correlation with estimated stone volume based on diameter.

    PubMed

    Wilhelm, Konrad; Miernik, Arkadiusz; Hein, Simon; Schlager, Daniel; Adams, Fabian; Benndorf, Matthias; Fritz, Benjamin; Langer, Mathias; Hesse, Albrecht; Schoenthaler, Martin; Neubauer, Jakob

    2018-06-02

    To validate AutoMated UroLithiasis Evaluation Tool (AMULET) software for kidney stone volumetry and compare its performance to standard clinical practice. Maximum diameter and volume of 96 urinary stones were measured as reference standard by three independent urologists. The same stones were positioned in an anthropomorphic phantom and CT scans acquired in standard settings. Three independent radiologists blinded to the reference values took manual measurements of the maximum diameter and automatic measurements of maximum diameter and volume. An "expected volume" was calculated based on manual diameter measurements using the formula: V=4/3 πr³. 96 stones were analyzed in the study. We had initially aimed to assess 100. Nine were replaced during data acquisition due of crumbling and 4 had to be excluded because the automated measurement did not work. Mean reference maximum diameter was 13.3 mm (5.2-32.1 mm). Correlation coefficients among all measured outcomes were compared. The correlation between the manual and automatic diameter measurements to the reference was 0.98 and 0.91, respectively (p<0.001). Mean reference volume was 1200 mm³ (10-9000 mm³). The correlation between the "expected volume" and automatically measured volume to the reference was 0.95 and 0.99, respectively (p<0.001). Patients' kidney stone burden is usually assessed according to maximum diameter. However, as most stones are not spherical, this entails a potential bias. Automated stone volumetry is possible and significantly more accurate than diameter-based volumetric calculations. To avoid bias in clinical trials, size should be measured as volume. However, automated diameter measurements are not as accurate as manual measurements.

  14. Determination of Shapes of Boattail Bodies of Revolution for Minimum Wave Drag

    NASA Technical Reports Server (NTRS)

    Adams, Mac C.

    1951-01-01

    By use of an approximate equation for the wave drag of slender bodies of revolution in a supersonic flow field, the optimum shapes of certain boattail bodies are determined for minimum wave drag. The properties of three specific families of bodies are determined, the first family consisting of bodies having a given length and base area and a contour passing through a prescribed point between the nose and base, the second family having fixed length, base area, and maximum area, and the third family having given length, volume, and base area. The method presented is easily generalized to determine minimum-wave-drag profile shapes which have contours that must pass through any prescribed number of points. According to linearized theory, the optimum profiles are found to have infinite slope at the nose but zero radius of curvature so that the bodies appear to have pointed noses, a zero slope at the body base, and no variation of wave drag with Mach number. For those bodies having a specified intermediate.diameter (that is, location and magnitude given), the maximum body diameter is shown to be larger, in general, than the specified diameter. It is also shown that, for bodies having a specified maximum diameter, the location of the maximum diameter is not arbitrary but is determined from the ratio of base diameter to maximum diameter.

  15. Morphometric analysis of cervical spinal canal diameter, transverse foramen, and pedicle width using computed tomography in Indian population.

    PubMed

    Sureka, Binit; Mittal, Aliza; Mittal, Mahesh K; Agarwal, Kanhaiya; Sinha, Mukul; Thukral, Brij Bhushan

    2018-01-01

    Accurate and detailed measurements of spinal canal diameter (SCD) and transverse foraminal morphometry are essential for understanding spinal column-related diseases and for surgical planning, especially for transpedicular screw fixation. This is especially because lateral cervical radiographs do not provide accurate measurements. This study was conducted to measure the dimensions of the transverse foramen sagittal and transverse diameters (SFD, TFD), SCD, and the distance of spinal canal from the transverse foramina (dSC-TF) at C1-C7 level in the Indian population. The study population comprised 84 male and 42 female subjects. The mean age of the study group was 44.63 years (range, 19-81 years). A retrospective study was conducted, and data were collected and analyzed for patients who underwent cervical spine computed tomography (CT) imaging for various reasons. One hundred and twenty-six patients were included in the study. Detailed readings were taken at all levels from C1-C7 for SCD, SFD, TFD, and dSc-TF. Values for male and female subjects were separately calculated and compared. For both the groups, the widest SCD were measured at the C1 level and the narrowest SCD at the C4 level. The narrowest SFD was measured at C7 for both male and female subjects on the right and left sides. The widest SFD was measured at C1 both for male and female subjects on the right and left side. The narrowest TFD on the left side was measured at C7 for male and at C1 for female subjects. The narrowest mean distance of dSC-TF was found to be at C4 for both male and female subjects on both left and right side. The computed tomographic (CT) imaging is better than conventional radiographs for the preoperative evaluation of cervical spine and for better understanding cervical spine morphometry. Care must be taken during transpedicular screw fixation, especially in female subjects, more so at the C2, C4, and C6 levels due to a decrease in the distance of dSC-TF.

  16. Inspection Method for Contact Condition of Soil on the Surface of Underground Pipe Utilizing Resonance of Transverse Lamb Wave

    NASA Astrophysics Data System (ADS)

    Tanigawa, Hiroshi; Seno, Hiroaki; Watanabe, Yoshiaki; Nakajima, Koshiro

    1998-05-01

    A nondestructive inspection method to estimate the contact condition of soil on the surface of an underground pipe, utilizing the resonance of a transverse Lamb wave circulating along the pipe wall is proposed.The Q factor of the resonance is considered and measured under some contact conditions by sweeping the vibrating frequency in a 150-mm-inner diameter Fiberglass Reinforced Plastic Mortar (FRPM) pipe. It is confirmed that the Q factor shows a clear response to the change in the contact conditions. For example, the Q factor is 8.4 when the pipe is in ideal contact with the soil plane and goes up to 19.2 when a 100-mm-diameter void is located at the contact surface of the soil.The spatial resolution of the proposed inspection method is also measured by moving the sensing point along the direction of laying the length of the pipe into a 85-mm-diameter void. The resolution of the proposed method is estimated at about 50 mm.

  17. Diagnostic performance of shear wave elastography of the breast according to scanning orientation.

    PubMed

    Kim, Solip; Choi, SeonHyeong; Choi, Yoonjung; Kook, Shin-Ho; Park, Hee Jin; Chung, Eun Chul

    2014-10-01

    To evaluate the influence of the scanning orientation on diagnostic performance measured by the mean elasticity, maximum elasticity, and fat-to-lesion elasticity ratio on ultrasound-based shear wave elastography in differentiating breast cancers from benign lesions. In this study, a total of 260 breast masses from 235 consecutive patients were observed from March 2012 to November 2012. For each lesion, the mean elasticity value, maximum elasticity value, and fat-to-lesion ratio were measured along two orthogonal directions, and all values were compared with pathologic results. There were 59 malignant and 201 benign lesions. Malignant masses showed higher mean elasticity, maximum elasticity, and fat-to-lesion ratio values than benign lesions (P < .0001). The areas under the receiver operating characteristic curves were as follows: average mean elasticity on both views, 0.870; mean elasticity on the transverse view, 0.866; maximum elasticity on both views, 0.865; maximum elasticity on the transverse view, 0.864; mean elasticity on the longitudinal view, 0.849; fat-to-lesion ratio on both views, 0.849; maximum elasticity on the longitudinal view, 0.845; fat-to-lesion ratio on the transverse view, 0.841; and fat-to-lesion ratio on the longitudinal view, 0.814. Intraclass correlation coefficients for agreement between the scanning directions were as follows: mean elasticity, 0.852; maximum elasticity, 0.842; fat-to-lesion ratio, 0.746, for masses; and mean elasticity, 0.392, for anterior mammary fat. Mean elasticity, maximum elasticity, and fat-to-lesion elasticity ratio values were helpful in differentiating benign and malignant breast masses. The scanning orientation did not significantly affect the diagnostic performance of shear wave elastography for breast masses. © 2014 by the American Institute of Ultrasound in Medicine.

  18. Comparison of Fluoroscopy and Computed Tomography for Tracheal Lumen Diameter Measurement and Determination of Intraluminal Stent Size in Healthy Dogs

    PubMed Central

    Williams, Jackie M.; Krebs, Ingar A.; Riedesel, Elizabeth A.; Zhao, Qianqian

    2015-01-01

    Tracheal collapse is a progressive airway disease that can ultimately result in complete airway obstruction. Intraluminal tracheal stents are a minimally invasive and viable treatment for tracheal collapse once the disease becomes refractory to medical management. Intraluminal stent size is chosen based on the maximum measured tracheal diameter during maximum inflation. The purpose of this prospective, cross-sectional study was to compare tracheal lumen diameter measurements and subsequent selected stent size using both fluoroscopy and CT and to evaluate inter- and intraobserver variability of the measurements. Seventeen healthy Beagles were anesthetized and imaged with fluoroscopy and CT with positive pressure ventilation to 20 cm H2O. Fluoroscopic and CT maximum tracheal diameters were measured by 3 readers. Three individual measurements were made at 8 pre-determined tracheal sites for dorsoventral (height) and laterolateral (width) dimensions. Tracheal diameters and stent sizes (based on the maximum tracheal diameter + 10%) were analyzed using a linear mixed model. CT tracheal lumen diameters were larger compared to fluoroscopy at all locations. When comparing modalities, fluoroscopic and CT stent sizes were statistically different. Greater overall variation in tracheal diameter measurement (height or width) existed for fluoroscopy compared to CT, both within and among observers. The greater tracheal diameter and lower measurement variability supported the use of CT for appropriate stent selection to minimize complications in veterinary patients. PMID:26784924

  19. Visible light optical coherence microscopy imaging of the mouse cortex with femtoliter volume resolution

    NASA Astrophysics Data System (ADS)

    Merkle, Conrad W.; Chong, Shau Poh; Kho, Aaron M.; Zhu, Jun; Kholiqov, Oybek; Dubra, Alfredo; Srinivasan, Vivek J.

    2018-02-01

    Most flying-spot Optical Coherence Tomography (OCT) and Optical Coherence Microscopy (OCM) systems use a symmetric confocal geometry, where the detection path retraces the illumination path starting from and ending with the spatial mode of a single mode optical fiber. Here, we describe a visible light OCM instrument that breaks this symmetry to improve transverse resolution without sacrificing collection efficiency in scattering tissue. This was achieved by overfilling a 0.3 numerical aperture (NA) water immersion objective on the illumination path, while maintaining a conventional Gaussian mode detection path (1/e2 intensity diameter 0.82 Airy disks), enabling 1.1 μm full-width at half-maximum (FWHM) transverse resolution. At the same time, a 0.9 μm FWHM axial resolution in tissue, achieved by a broadband visible light source, enabled femtoliter volume resolution. We characterized this instrument according to paraxial coherent microscopy theory, and then used it to image the meningeal layers, intravascular red blood cell-free layer, and myelinated axons in the mouse neocortex in vivo through the thinned skull. Finally, by introducing a 0.8 NA water immersion objective, we improved the lateral resolution to 0.44 μm FWHM, which provided a volumetric resolution of 0.2 fL, revealing cell bodies in cortical layer I of the mouse brain with OCM for the first time.

  20. CHARACTERIZING DETONATING LX-17 CHARGES CROSSING A TRANSVERSE AIR GAP WITH EXPERIMENTS AND MODELING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lauderbach, L M; Souers, P C; Garcia, F

    2009-06-26

    Experiments were performed using detonating LX-17 (92.5% TATB, 7.5% Kel-F by weight) charges with various width transverse air gaps with manganin peizoresistive in-situ gauges present. The experiments, performed with 25 mm diameter by 25 mm long LX-17 pellets with the transverse air gap in between, showed that transverse gaps up to about 3 mm could be present without causing the detonation wave to fail to continue as a detonation. The Tarantula/JWL{sup ++} code was utilized to model the results and compare with the in-situ gauge records with some agreement to the experimental data with additional work needed for a bettermore » match to the data. This work will present the experimental details as well as comparison to the model results.« less

  1. Reproducibility of Abdominal Aortic Aneurysm Diameter Measurement and Growth Evaluation on Axial and Multiplanar Computed Tomography Reformations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dugas, Alexandre; Therasse, Eric; Kauffmann, Claude

    2012-08-15

    Purpose: To compare different methods measuring abdominal aortic aneurysm (AAA) maximal diameter (Dmax) and its progression on multidetector computed tomography (MDCT) scan. Materials and Methods: Forty AAA patients with two MDCT scans acquired at different times (baseline and follow-up) were included. Three observers measured AAA diameters by seven different methods: on axial images (anteroposterior, transverse, maximal, and short-axis views) and on multiplanar reformation (MPR) images (coronal, sagittal, and orthogonal views). Diameter measurement and progression were compared over time for the seven methods. Reproducibility of measurement methods was assessed by intraclass correlation coefficient (ICC) and Bland-Altman analysis. Results: Dmax, as measuredmore » on axial slices at baseline and follow-up (FU) MDCTs, was greater than that measured using the orthogonal method (p = 0.046 for baseline and 0.028 for FU), whereas Dmax measured with the orthogonal method was greater those using all other measurement methods (p-value range: <0.0001-0.03) but anteroposterior diameter (p = 0.18 baseline and 0.10 FU). The greatest interobserver ICCs were obtained for the orthogonal and transverse methods (0.972) at baseline and for the orthogonal and sagittal MPR images at FU (0.973 and 0.977). Interobserver ICC of the orthogonal method to document AAA progression was greater (ICC = 0.833) than measurements taken on axial images (ICC = 0.662-0.780) and single-plane MPR images (0.772-0.817). Conclusion: AAA Dmax measured on MDCT axial slices overestimates aneurysm size. Diameter as measured by the orthogonal method is more reproducible, especially to document AAA progression.« less

  2. SU-F-T-129: Impact of Radial Fluctuations in RBE for Therapeutic Proton Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butkus, M; Palmer, T

    Purpose: To evaluate the off axis relative biological effectiveness (RBE) for actively scanned proton beams and determine if a constant radial RBE can be assumed. Methods: The PHITS Monte Carlo code paired with a microscopic analytical function was used to determine probability distribution functions of the lineal energy in 0.3µm diameter spheres throughout a water phantom. Twenty million primary protons were simulated for a 0.6cm diameter pencil beam. Beam energies corresponding to Bragg Peak depths of 50, 100, 150, 200, 250, and 300mm were used and evaluated transversely every millimeter and radially for annuli of 1.0, 2.0, 3.0, 3.2, 3.4,more » 3.6, 4.0, 5.0, 10.0, 15.0, 20.0 and 25.0mm outer radius. The acquired probability distributions were reduced to dose-mean lineal energies and applied to the modified microdosimetric kinetic model, for human submandibular gland (HSG) cells, to calculate relative biological effectiveness (RBE) compared to 60Co beams at the 10% survival threshold. Results: RBE was generally seen to increase as distance from the central axis (CAX) increased. However, this increase was only seen in low dose regions and its overall effects on the transverse biological dose remains low. In the entrance region of the phantom (10mm depth), minimum and maximum calculated RBEs varied between 15.22 and 18.88% for different energies. At the Bragg peak, this difference ranged from 3.15 to 26.77%. Despite these rather large variations the dose-weighted RBE and the CAX RBE varied by less than 0.14% at 10mm depth and less than 0.16% at the Bragg peak. Similarly small variations were found at all depths proximal of the Bragg peak. Conclusion: Although proton RBE does vary radially, its overall effect on biological dose is minimal and the use of a radially constant RBE in treatment planning for scanned proton beams would not produce large errors.« less

  3. Lamb waves increase sensitivity in nondestructive testing

    NASA Technical Reports Server (NTRS)

    Di Novi, R.

    1967-01-01

    Lamb waves improve sensitivity and resolution in the detection of small defects in thin plates and small diameter, thin-walled tubing. This improvement over shear waves applies to both longitudinal and transverse flaws in the specimens.

  4. Morphological and radiological study of ossified superior transverse scapular ligament as potential risk factor of suprascapular nerve entrapment.

    PubMed

    Polguj, Michał; Sibiński, Marcin; Grzegorzewski, Andrzej; Waszczykowski, Michał; Majos, Agata; Topol, Mirosław

    2014-01-01

    The suprascapular notch is covered superiorly by the superior transverse scapular ligament. This region is the most common place of suprascapular nerve entrapment formation. The study was performed on 812 specimens: 86 dry scapulae, 104 formalin-fixed cadaveric shoulders, and 622 computer topography scans of scapulae. In the cases with completely ossified superior transverse scapular ligament, the following measurements were performed: proximal and distal width of the bony bridge, middle transverse and vertical diameter of the suprascapular foramen, and area of the suprascapular foramen. An ossified superior transverse scapular ligament was observed more often in men and in the right scapula. The mean age of the subjects with a completely ossified superior transverse scapular ligament was found to be similar than in those without ossification. The ossified band-shaped type of superior transverse scapular ligament was more common than the fan-shaped type and reduced the space below the ligament to a significantly greater degree. The ossified band-shaped type should be taken into consideration as a potential risk factor in the formation of suprascapular nerve entrapment. It could explain the comparable frequency of neuropathy in various populations throughout the world despite the significant differences between them in occurrence of ossified superior transverse scapular ligament.

  5. The Effect of Connecting-passage Diameter on the Performance of a Compression-ignition Engine with a Precombustion Chamber

    NASA Technical Reports Server (NTRS)

    Moore, C S; Collins, J H

    1932-01-01

    Results of motoring tests are presented showing the effect of passage diameter on chamber and cylinder compression pressures, maximum pressure differences, and f.m.e.p. over a speed range from 300 to 1,750 r.p.m. Results of engine performance tests are presented which show the effect of passage diameter on m.e.p., explosion pressures, specific fuel consumption, and rates of pressure rise for a range of engine speeds from 500 to 1,500 r.p.m. The cylinder compression pressure, the maximum pressure difference, and the f.m.e.p. decreased rapidly as the passage diameter increased to 29/64 inch, whereas further increase in passage diameter effected only a slight change. The most suitable passage diameter for good engine performance and operating characteristics was 29/64 inch. Passage diameter became less critical with a decrease in engine speed. Therefore, the design should be based on maximum operating speed. Optimum performance and satisfactory combustion control could not be obtained by means of any single diameter of the connecting passage.

  6. An analytical fiber bundle model for pullout mechanics of root bundles

    NASA Astrophysics Data System (ADS)

    Cohen, D.; Schwarz, M.; Or, D.

    2011-09-01

    Roots in soil contribute to the mechanical stability of slopes. Estimation of root reinforcement is challenging because roots form complex biological networks whose geometrical and mechanical characteristics are difficult to characterize. Here we describe an analytical model that builds on simple root descriptors to estimate root reinforcement. Root bundles are modeled as bundles of heterogeneous fibers pulled along their long axes neglecting root-soil friction. Analytical expressions for the pullout force as a function of displacement are derived. The maximum pullout force and corresponding critical displacement are either derived analytically or computed numerically. Key model inputs are a root diameter distribution (uniform, Weibull, or lognormal) and three empirical power law relations describing tensile strength, elastic modulus, and length of roots as functions of root diameter. When a root bundle with root tips anchored in the soil matrix is pulled by a rigid plate, a unique parameter, ?, that depends only on the exponents of the power law relations, dictates the order in which roots of different diameters break. If ? < 1, small roots break first; if ? > 1, large roots break first. When ? = 1, all fibers break simultaneously, and the maximum tensile force is simply the roots' mean force times the number of roots in the bundle. Based on measurements of root geometry and mechanical properties, the value of ? is less than 1, usually ranging between 0 and 0.7. Thus, small roots always fail first. The model shows how geometrical and mechanical characteristics of roots and root diameter distribution affect the pullout force, its maximum and corresponding displacement. Comparing bundles of roots that have similar mean diameters, a bundle with a narrow variance in root diameter will result in a larger maximum force and a smaller displacement at maximum force than a bundle with a wide diameter distribution. Increasing the mean root diameter of a bundle without changing the distribution's shape increases both the maximum force and corresponding displacement. Estimates of the maximum pullout forces for bundles of 100 roots with identical diameter distribution for different species range from less than 1 kN for barley (Hordeum vulgare) to almost 16 kN for pistachio (Pistacia lentiscus). The model explains why a commonly used assumption that all roots break simultaneously overpredicts the maximum pullout force by a factor of about 1.6-2. This ratio may exceed 3 for diameter distributions that have a large number of small roots like the exponential distribution.

  7. [Anatomy study on micro transverse flap pedicled with superfical palmar branch of radial artery from palmar wrist].

    PubMed

    Zhao, Min; Tian, Dehu; Shao, Xinzhong; Li, Dacun; Li, Jianfeng; Liu, Jingda; Zhao, Liang; Li, Hailei; Wang, Xiaolei; Zhang, Wentong; Wu, Jinying; Yuan, Zuoxiong

    2013-07-01

    To study the anatomical basis of micro transverse flap pedicled with the superfical palmar branch of radial artery from the palmar wrist for using this free flap to repair soft tissue defect of the finger. Thirty-eight fresh upper limb specimens (22 males and 16 females; aged 26-72 years with an average of 36 years; at left and right sides in 19 limbs respectively) were dissected and observed under operating microscope. Two specimens were made into casting mould of artery with bones, and 2 specimens were injected with red emulsion in radial artery. Thirty-four specimens were injected with 1% gentian violet solution in the superfical palmar branch of the radial artery. A transverse oval flap in the palmar wrist was designed, the axis of the flap was the distal palmar crease. The origin, distribution, and anastomosis of the superfical palmar branch of the radial artery were observed. The superficial palmar branch of the radial artery was constantly existed, it usually arises from the main trunk of the radial artery, 1.09-3.60 cm to proximal styloid process of radius. There were about 2-5 branches between the origin and the tubercle of scaphoid bone. The origin diameter was 1.00-3.00 mm, and the distal diameter at the styloid process of radius was 1.00-2.90 mm. The venous return of flap passed through 2 routes, and the innervations of the flap mainly from the palmar cutaneous branch of the median nerve. The area of the flap was 4 cm x 2 cm-6 cm x 2 cm. The origin and courses of the superficial palmar branch of the radial artery is constant, and its diameter is similar to that of the digital artery. A transverse oval flap pedicled with the superfical palmar branch of radial artery in the palmar wrist can be designed to repair defects of the finger.

  8. Electro-optical properties of zigzag and armchair boron nitride nanotubes under a transverse electric field: Tight binding calculations

    NASA Astrophysics Data System (ADS)

    Chegel, Raad; Behzad, Somayeh

    2012-02-01

    The electro-optical properties of zigzag and armchair BNNTs in a uniform transverse electric field are investigated within tight binding approximation. It is found that the electric field modifies the band structure and splits band degeneracy where these effects reflect in the DOS and JDOS spectra. A decrease in the band gap, as a function of the electric field, is observed. This gap reduction increases with the diameter and it is independent of chirality. An analytic function to estimate the electric field needed for band gap closing is proposed which is in good agreement with DFT results. In additional, we show that the larger diameter tubes are more sensitive than small ones. Number and position of peaks in DOS and JDOS spectra for armchair and zigzag tubes with similar radius are dependent on electric field strength.

  9. Characterizing Detonating LX-17 Charges Crossing a Transverse Air Gap with Experiments and Modeling

    NASA Astrophysics Data System (ADS)

    Lauderbach, Lisa M.; Souers, P. Clark; Garcia, Frank; Vitello, Peter; Vandersall, Kevin S.

    2009-06-01

    Experiments were performed using detonating LX-17 (92.5% TATB, 7.5% Kel-f by weight) charges with various width transverse air gaps both with and without manganin peizoresistive in-situ gauges present. The experiments, performed with 25 mm diameter by 25 mm long LX-17 pellets with the transverse air gap in between, showed that transverse gaps up to about 3 mm could be present without causing the detonation wave to fail to continue as a detonation. A JWL++/Tarantula code was utilized to model the results and compare with the in-situ gauge records with reasonable agreement to the experimental data. This work will present the experimental details as well as comparison to the model results. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  10. Eye Size at Birth in Prosimian Primates: Life History Correlates and Growth Patterns

    PubMed Central

    Cummings, Joshua R.; Muchlinski, Magdalena N.; Kirk, E. Christopher; Rehorek, Susan J.; DeLeon, Valerie B.; Smith, Timothy D.

    2012-01-01

    Background Primates have large eyes relative to head size, which profoundly influence the ontogenetic emergence of facial form. However, growth of the primate eye is only understood in a narrow taxonomic perspective, with information biased toward anthropoids. Methodology/Principal Findings We measured eye and bony orbit size in perinatal prosimian primates (17 strepsirrhine taxa and Tarsius syrichta) to infer the extent of prenatal as compared to postnatal eye growth. In addition, multiple linear regression was used to detect relationships of relative eye and orbit diameter to life history variables. ANOVA was used to determine if eye size differed according to activity pattern. In most of the species, eye diameter at birth measures more than half of that for adults. Two exceptions include Nycticebus and Tarsius, in which more than half of eye diameter growth occurs postnatally. Ratios of neonate/adult eye and orbit diameters indicate prenatal growth of the eye is actually more rapid than that of the orbit. For example, mean neonatal transverse eye diameter is 57.5% of the adult value (excluding Nycticebus and Tarsius), compared to 50.8% for orbital diameter. If Nycticebus is excluded, relative gestation age has a significant positive correlation with relative eye diameter in strepsirrhines, explaining 59% of the variance in relative transverse eye diameter. No significant differences were found among species with different activity patterns. Conclusions/Significance The primate developmental strategy of relatively long gestations is probably tied to an extended period of neural development, and this principle appears to apply to eye growth as well. Our findings indicate that growth rates of the eye and bony orbit are disassociated, with eyes growing faster prenatally, and the growth rate of the bony orbit exceeding that of the eyes after birth. Some well-documented patterns of orbital morphology in adult primates, such as the enlarged orbits of nocturnal species, mainly emerge during postnatal development. PMID:22567127

  11. Comparison of Intrauterine Antibiotics versus Ozone Medical Use in Sheep with Retained Placenta and Following Obstetric Assistance.

    PubMed

    Đuričić, D; Valpotić, H; Žura Žaja, I; Samardžija, M

    2016-08-01

    This study outlines a new approach to reproductive tract treatment using ozone foam spray for certain ovine obstetrical problems, such as retained foetal membranes and possible uterine infections following obstetric assistance (OA), in comparison with classical antibiotics treatments. The study was conducted on 256 ewes from 11 sheep farms in north-western Croatia. A total of 139 ewes were diagnosed with dystocia (DT) and 49 with retention of placenta (RP). Ewes with RP were treated either with ozone foam spray (Riger spray G; Novagen(®) ) applied into the body of the uterus for 2-3 s (first or RPO group; n = 24) or with two foaming, intrauterine tablets of oxytetracycline hydrochloride (Geomycin(®) F) (second or RPA group; n = 25). The third and fourth groups consisted of ewes that received OA for dystocia (including ringwomb, foetal oversize and assistance of abnormal position and posture). The third group (DTO; n = 70) was treated with ozone foam spray, while ewes in fourth group (DTA; n = 69) were treated with antibiotics. The ewes in the control group (CTL) with physiological puerperium were randomly selected (n = 70) from all herds. Transrectal ultrasonography (transversal diameter of uterine horns) was used for the control of uterus regression on days 2 and 25 after parturition. There was a difference in transversal uterine horn diameter in the RP groups, that is RPO and RPA (5.40 ± 0.53 cm vs. 5.43 ± 0.40 cm), ewes with dystocia, that is DTO and DTA (5.37 ± 0.49 cm vs. 5.54 ± 0.60 cm) and ewes from the CTL group (4.98 ± 0.35 cm) one day after parturition. Average transversal uterine diameter of all groups at day 25 post-partum was 1.80 ± 0.15 cm. The intrauterine ozone treatment in ewes with RP and after manual obstetrics attained similar results to spontaneously delivered ewes (CTL group), showed as the physiological regression of the uterus with a similar transversal diameter without the presence of lochia in the uterine lumen, indicating that this could be a novel potential alternative therapy. © 2016 Blackwell Verlag GmbH.

  12. Association of deep venous thrombosis with calf vein diameter in acute hemorrhagic stroke.

    PubMed

    Ogata, Toshiyasu; Yasaka, Masahiro; Wakugawa, Yoshiyuki; Kitazono, Takanari; Okada, Yasushi

    2013-10-01

    We investigated the association between the development of deep venous thrombosis (DVT) and calf vein diameter in patients with acute hemorrhagic stroke. We measured the maximum diameter of paralytic side posttibial veins (PTVs) and peroneal veins (PVs) in 49 patients with intracerebral hemorrhage on admission and at 2 weeks after stroke onset by ultrasonography. We also examined for the presence or absence of DVT, and then analyzed the association of DVT with the maximum vein diameter. At 2 weeks after stroke, DVTs were detected in PTVs in 7 patients and in PVs in 6 patients. The maximum calf vein diameters at 2 weeks were significantly greater in patients with DVT compared with those without DVT (PTV, P = .033; PV, P = .015). Although calf vein diameter at admission did not influence the future incidence of DVT in patients with intracerebral hemorrhage, the presence of DVT was associated with calf vein dilatation. Copyright © 2013 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  13. Humeral development from neonatal period to skeletal maturity--application in age and sex assessment.

    PubMed

    Rissech, Carme; López-Costas, Olalla; Turbón, Daniel

    2013-01-01

    The goal of the present study is to examine cross-sectional information on the growth of the humerus based on the analysis of four measurements, namely, diaphyseal length, transversal diameter of the proximal (metaphyseal) end of the shaft, epicondylar breadth and vertical diameter of the head. This analysis was performed in 181 individuals (90 ♂ and 91 ♀) ranging from birth to 25 years of age and belonging to three documented Western European skeletal collections (Coimbra, Lisbon and St. Bride). After testing the homogeneity of the sample, the existence of sexual differences (Student's t- and Mann-Whitney U-test) and the growth of the variables (polynomial regression) were evaluated. The results showed the presence of sexual differences in epicondylar breadth above 20 years of age and vertical diameter of the head from 15 years of age, thus indicating that these two variables may be of use in determining sex from that age onward. The growth pattern of the variables showed a continuous increase and followed first- and second-degree polynomials. However, growth of the transversal diameter of the proximal end of the shaft followed a fourth-degree polynomial. Strong correlation coefficients were identified between humeral size and age for each of the four metric variables. These results indicate that any of the humeral measurements studied herein is likely to serve as a useful means of estimating sub-adult age in forensic samples.

  14. Volumetric Growth of the Liver in the Human Fetus: An Anatomical, Hydrostatic, and Statistical Study.

    PubMed

    Szpinda, Michał; Paruszewska-Achtel, Monika; Woźniak, Alina; Mila-Kierzenkowska, Celestyna; Elminowska-Wenda, Gabriela; Dombek, Małgorzata; Szpinda, Anna; Badura, Mateusz

    2015-01-01

    Using anatomical, hydrostatic, and statistical methods, liver volumes were assessed in 69 human fetuses of both sexes aged 18-30 weeks. No sex differences were found. The median of liver volume achieved by hydrostatic measurements increased from 6.57 cm(3) at 18-21 weeks through 14.36 cm(3) at 22-25 weeks to 20.77 cm(3) at 26-30 weeks, according to the following regression: y = -26.95 + 1.74 × age ± Z × (-3.15 + 0.27 × age). The median of liver volume calculated indirectly according to the formula liver volume = 0.55 × liver length × liver transverse diameter × liver sagittal diameter increased from 12.41 cm(3) at 18-21 weeks through 28.21 cm(3) at 22-25 weeks to 49.69 cm(3) at 26-30 weeks. There was a strong relationship (r = 0.91, p < 0.001) between the liver volumes achieved by hydrostatic (x) and indirect (y) methods, expressed by y = -0.05 + 2.16x ± 7.26. The liver volume should be calculated as follows liver volume = 0.26 × liver length × liver transverse diameter × liver sagittal diameter. The age-specific liver volumes are of great relevance in the evaluation of the normal hepatic growth and the early diagnosis of fetal micro- and macrosomias.

  15. Role of parenteral testosterone in hypospadias: A study from a teaching hospital in India

    PubMed Central

    Ahmad, Reyaz; Chana, Rajendra Singh; Ali, Syed Manazir; Khan, Shehtaj

    2011-01-01

    Objectives: To evaluate the effect of parenteral testosterone on penile length, preputial skin and side effects in patients with hypospadias. Materials and Methods: 23 patients with hypospadias were included in this study. An oily solution, each ml of which contained testosterone propionate 25 mg, and testosterone enanthate 110 mg, equivalent to 100 mg of testosterone was given deep intramuscularly 4, 3 and 2 weeks before reconstructive surgery at the dose of 2 mg/kg body weight. Increase in penile length, transverse preputial diameter, and diameter at the base of penis were noted. Basal testosterone levels were obtained before the institution of therapy and on the day of operation. In addition, side effect such as development of pubic hair and delay in bone age was noted. Results: Following parenteral testosterone administration, the mean increase in penile length, transverse preputial diameter and diameter at the base of penis was 1.35±0.40 cm (P<0.001), 1.40±0.47 cm (P<0.001), and 0.72±0.47 cm (P<0.001), respectively. Serum testosterone level after injection was well within normal range for that age. Minimal side effects were noted in form of development of fine pubic hair. Conclusion: We conclude that parenteral testosterone can be safely used to improve the surgical outcome of hypospadias repair. PMID:21976926

  16. Ultrasonographic measurement of the optic nerve sheath diameter and its association with eyeball transverse diameter in 585 healthy volunteers.

    PubMed

    Kim, Dong Hwan; Jun, Jin-Sun; Kim, Ryul

    2017-11-21

    The optic nerve sheath diameter (ONSD) is considered as an indirect marker for intracranial pressure (ICP). However, the optimal cut-off value for an abnormal ONSD indicating elevated ICP and its associated factors have been unclear. Thus, we investigated normative values for the ONSD using ultrasonography and investigate the potential factors affecting it. We prospectively recruited healthy volunteers between September 2016 and March 2017. A total of 585 individuals were included, in which the mean ONSD was 4.11 mm [95% confidence interval (CI), 4.09-4.14 mm]. Although ONSD was correlated with sex (p = 0.015), height (p = 0.003), and eyeball transverse diameter (ETD) (p < 0.001) in simple linear regression analyses, multiple linear regression analysis revealed that only ETD was independently associated with ONSD (p < 0.001). Accordingly, we further established a normative value for the ONSD/ETD ratio and its associated factors. The mean ONSD/ETD ratio was 0.18 (95% CI, 0.18-0.18), but the ONSD/ETD ratio was not correlated with sex, height, weight, body mass index, and head circumference. Our findings suggest that the ONSD had a strong correlation with ETD, and ONSD/ETD ratio might provide more reliable data than ONSD itself as a marker of ICP.

  17. Enhanced spin transfer torque effect for transverse domain walls in cylindrical nanowires

    NASA Astrophysics Data System (ADS)

    Franchin, Matteo; Knittel, Andreas; Albert, Maximilian; Chernyshenko, Dmitri S.; Fischbacher, Thomas; Prabhakar, Anil; Fangohr, Hans

    2011-09-01

    Recent studies have predicted extraordinary properties for transverse domain walls in cylindrical nanowires: zero depinning current, the absence of the Walker breakdown, and applications as domain wall oscillators. In order to reliably control the domain wall motion, it is important to understand how they interact with pinning centers, which may be engineered, for example, through modulations in the nanowire geometry (such as notches or extrusions) or in the magnetic properties of the material. In this paper we study the motion and depinning of transverse domain walls through pinning centers in ferromagnetic cylindrical nanowires. We use (i) magnetic fields and (ii) spin-polarized currents to drive the domain walls along the wire. The pinning centers are modelled as a section of the nanowire which exhibits a uniaxial crystal anisotropy where the anisotropy easy axis and the wire axis enclose a variable angle θP. Using (i) magnetic fields, we find that the minimum and the maximum fields required to push the domain wall through the pinning center differ by 30%. On the contrary, using (ii) spin-polarized currents, we find variations of a factor 130 between the minimum value of the depinning current density (observed for θP=0∘, i.e., anisotropy axis pointing parallel to the wire axis) and the maximum value (for θP=90∘, i.e., anisotropy axis perpendicular to the wire axis). We study the depinning current density as a function of the height of the energy barrier of the pinning center using numerical and analytical methods. We find that for an industry standard energy barrier of 40kBT, a depinning current of about 5μA (corresponding to a current density of 6×1010A/m2 in a nanowire of 10nm diameter) is sufficient to depin the domain wall. We reveal and explain the mechanism that leads to these unusually low depinning currents. One requirement for this depinning mechanism is for the domain wall to be able to rotate around its own axis. With the right barrier design, the spin torque transfer term is acting exactly against the damping in the micromagnetic system, and thus the low current density is sufficient to accumulate enough energy quickly. These key insights may be crucial in furthering the development of novel memory technologies, such as the racetrack memory, that can be controlled through low current densities.

  18. The prognostic impact of clinical and CT parameters in patients with pontine hemorrhage.

    PubMed

    Dziewas, Rainer; Kremer, Marion; Lüdemann, Peter; Nabavi, Darius G; Dräger, Bianca; Ringelstein, Bernd

    2003-01-01

    In patients with pontine hemorrhage (PH), an accurate prognostic assessment is critical for establishing a reasonable therapeutic approach. The initial clinical symptoms and computed tomography (CT) features were analyzed with multivariate regression analysis in 39 consecutive patients with PH. PHs were classified into three types: (1) large paramedian, (2) basal or basotegmental and (3) lateral tegmental, and the hematomas' diameters were measured. The patients' outcome was evaluated. Twenty-seven patients (69%) died and 12 (31%) survived for more than 1 year after PH. The symptom most predictive of death was coma on admission. The large paramedian type of PH predicted a poor prognosis, whereas the lateral tegmental type was associated with a favorable outcome. The transverse hematoma diameter was also related to outcome, with the threshold value found to be 20 mm. We conclude that PH outcome can be estimated best by combining the CT parameters 'large paramedian PH' and 'transverse diameter >/=20 mm' with the clinical variable 'coma on admission'. Survival is unlikely if all 3 features are present, whereas survival may be expected if only 1 or none of these features is found. Copyright 2003 S. Karger AG, Basel

  19. Thermophysical ESEM and TEM Characterization of Carbon Fibers CTE, Spectroscopy and Roughness Studies at High Temperatures

    NASA Technical Reports Server (NTRS)

    Ochoa, Ozden O.

    2004-01-01

    Accurate determination of the transverse properties of carbon fibers is important for assessment and prediction of local material as well as global structural response of composite components. However the measurements are extremely difficult due to the very small diameters of the fibers (few microns only) and must be conducted within a microscope. In this work, environmental scanning electron microscope (ESEM) and transmission electron microscope (TEM) are used to determine the transverse coefficient of thermal expansion of different carbon fibers as a function of temperature.

  20. Numerical studies of transverse curvature effects on transonic flow stability

    NASA Technical Reports Server (NTRS)

    Macaraeg, M. G.; Daudpota, Q. I.

    1992-01-01

    A numerical study of transverse curvature effects on compressible flow temporal stability for transonic to low supersonic Mach numbers is presented for axisymmetric modes. The mean flows studied include a similar boundary-layer profile and a nonsimilar axisymmetric boundary-layer solution. The effect of neglecting curvature in the mean flow produces only small quantitative changes in the disturbance growth rate. For transonic Mach numbers (1-1.4) and aerodynamically relevant Reynolds numbers (5000-10,000 based on displacement thickness), the maximum growth rate is found to increase with curvature - the maximum occurring at a nondimensional radius (based on displacement thickness) between 30 and 100.

  1. Transverse stresses and modes of failure in tree branches and other beams.

    PubMed

    Ennos, A R; van Casteren, A

    2010-04-22

    The longitudinal stresses in beams subjected to bending also set up transverse stresses within them; they compress the cross section when the beam's curvature is being increased and stretch it when its curvature is being reduced. Analysis shows that transverse stresses rise to a maximum at the neutral axis and increase with both the bending moment applied and the curvature of the beam. These stresses can qualitatively explain the fracture behaviour of tree branches. Curved 'hazard beams' that are being straightened split down the middle because of the low transverse tensile strength of wood. By contrast, straight branches of light wood buckle when they are bent because of its low transverse compressive strength. Branches of denser wood break, but the low transverse tensile strength diverts the crack longitudinally when the fracture has only run half-way across the beam, to produce their characteristic 'greenstick fracture'. The bones of young mammals and uniaxially reinforced composite beams may also be prone to greenstick fracture because of their lower transverse tensile strength.

  2. Giant transversal particle diffusion in a longitudinal magnetic ratchet.

    PubMed

    Tierno, Pietro; Reimann, Peter; Johansen, Tom H; Sagués, Francesc

    2010-12-03

    We study the transversal motion of paramagnetic particles on a uniaxial garnet film, exhibiting a longitudinal ratchet effect in the presence of an oscillating magnetic field. Without the field, the thermal diffusion coefficient obtained by video microscopy is D(0) ≈ 3 × 10(-4)  μm2/s. With the field, the transversal diffusion exhibits a giant enhancement by almost four decades and a pronounced maximum as a function of the driving frequency. We explain the experimental findings with a theoretical interpretation in terms of random disorder effects within the magnetic film.

  3. High-power, cladding-pumped all-fiber laser with selective transverse mode generation property.

    PubMed

    Li, Lei; Wang, Meng; Liu, Tong; Leng, Jinyong; Zhou, Pu; Chen, Jinbao

    2017-06-10

    We demonstrate, to the best of our knowledge, the first cladding-pumped all-fiber oscillator configuration with selective transverse mode generation based on a mode-selective fiber Bragg grating pair. Operating in the second-order (LP 11 ) mode, maximum output power of 4.2 W is obtained with slope efficiency of about 38%. This is the highest reported output power of single higher-order transverse mode generation in an all-fiber configuration. The intensity distribution profile and spectral evolution have also been investigated in this paper. Our work suggests the potential of realizing higher power with selective transverse mode operation based on a mode-selective fiber Bragg grating pair.

  4. Bony Regeneration of the Sella after Transsphenoidal Pituitary Surgery.

    PubMed

    Yahia-Cherif, Mehdi; Delpierre, Isabelle; Hassid, Sergio; De Witte, Olivier

    2016-04-01

    The purpose of this study is to demonstrate the possible bony regrowth of the sella after transsphenoidal surgery without any intraoperative sellar reconstruction. Radiologic findings of the sella were reviewed in patients with pituitary tumors treated by transsphenoidal surgery. In 17 patients who had postoperative cranial computed tomography scans, bony regeneration of the sellar floor was evaluated by comparing immediate and late postoperative scans. The bony opening reduction was measured in transverse and sagittal planes. The median bony opening diameter in the transverse plane was 8.8 mm (interquartile range [IQR] 5.7-11.4) on the first scan and 4.2 mm (IQR 0.8-6.8) on the second scan. In the sagittal plane, it was 4.8 mm (IQR 1.8-6.8) on the first scan and 2.9 mm (IQR 1.6-3.9) on the second scan. These changes occurred in a median time of 36 months (IQR 22-42). There was a statistically significant decrease of the bony opening diameters in both the transverse and sagittal planes (P < 0.0001 and P = 0.0004, respectively). Bone regeneration was observed in 16 of the 17 patients (approximately 94%). There is a natural bony regeneration of the sella after transsphenoidal pituitary surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Maximum nondiffracting propagation distance of aperture-truncated Airy beams

    NASA Astrophysics Data System (ADS)

    Chu, Xingchun; Zhao, Shanghong; Fang, Yingwu

    2018-05-01

    Airy beams have called attention of many researchers due to their non-diffracting, self-healing and transverse accelerating properties. A key issue in research of Airy beams and its applications is how to evaluate their nondiffracting propagation distance. In this paper, the critical transverse extent of physically realizable Airy beams is analyzed under the local spatial frequency methodology. The maximum nondiffracting propagation distance of aperture-truncated Airy beams is formulated and analyzed based on their local spatial frequency. The validity of the formula is verified by comparing the maximum nondiffracting propagation distance of an aperture-truncated ideal Airy beam, aperture-truncated exponentially decaying Airy beam and exponentially decaying Airy beam. Results show that the formula can be used to evaluate accurately the maximum nondiffracting propagation distance of an aperture-truncated ideal Airy beam. Therefore, it can guide us to select appropriate parameters to generate Airy beams with long nondiffracting propagation distance that have potential application in the fields of laser weapons or optical communications.

  6. Whispering gallery mode photoemission from self-assembled poly-para-phenylenevinylene microspheres

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kushida, Soh; Yamamoto, Yohei; Braam, Daniel

    2015-12-31

    Poly[2-methoxy-5-(3,7-dimethyloctyloxy)-1,4-phenylenevinylene] (MDMOPPV) self-assembles to form well-defined spheres with several micrometers in diameter upon addition of a methanol vapor into a chloroform solution of MDMOPPV. The single sphere of MDMOPPV with 5.7 µm diameter exhibits whispering gallery mode (WGM) photoemission upon excitation with focused laser beam. The periodic emission lines are characterized by transverse electric and magnetic WGMs, and Q-factor reaches ∼345 at the highest.

  7. Use of computed tomography to define a sacral safe corridor for placement of 2.7 mm cortical screws in feline sacroiliac luxation.

    PubMed

    Philp, Helen; Durand, Alexane; De Vicente, Felipe

    2018-06-01

    Objectives This study aimed to define a safe corridor for 2.7 mm cortical sacroiliac screw insertion in the dorsal plane (craniocaudal direction) using radiography and CT, and in the transverse plane (dorsoventral direction) using CT in feline cadavers. A further aim was to compare the values obtained by CT with those previously reported by radiography in the transverse plane. Methods Thirteen pelvises were retrieved from feline cadavers and dissected to expose one of the articular surfaces of the sacrum. A 2.7 mm screw was placed in the sacrum to a depth of approximately 1 cm in each exposed articular surface. Dorsoventral radiography and CT scanning of each specimen were performed. Multiplanar reconstructions were performed to allow CT evaluation in both the dorsal and transverse planes. Calculations were made to find the maximum, minimum and optimum angles for screw placement in craniocaudal (radiography and CT) and dorsoventral (CT) directions when using a 2.7 mm cortical screw. Results Radiographic measurement showed a mean optimum craniocaudal angle of 106° (range 97-112°). The mean minimum angle was 95° (range 87-107°), whereas the mean maximum angle was 117° (108-124°). Measurement of the dorsal CT scan images showed a mean optimum craniocaudal angle of 101° (range 94-110°). The mean minimum angle was 90° (range 83-99°), whereas the mean maximum angle was 113° (104-125°). The transverse CT scan images showed a mean dorsoventral minimum angle of 103° (range 95-113°), mean maximum angle of 115° (104-125°) and mean optimum dorsoventral angle of 111° (102-119°). Conclusions and relevance An optimum craniocaudal angle of 101° is recommended for 2.7 mm cortical screw placement in the feline sacral body, with a safety margin between 99° and 104°. No single angle can be recommended in the dorsoventral direction and therefore preoperative measuring on individual cats using CT images is recommended to establish the ideal individual angle in the transverse plane.

  8. Microstructure, Texture, and Mechanical Behavior of As-cast Ni-Fe-W Matrix Alloy

    NASA Astrophysics Data System (ADS)

    Rao, A. Sambasiva; Manda, Premkumar; Mohan, M. K.; Nandy, T. K.; Singh, A. K.

    2018-04-01

    This article describes the tensile properties, flow, and work-hardening behavior of an experimental alloy 53Ni-29Fe-18W in as-cast condition. The microstructure of the alloy 53Ni-29Fe-18W displays single phase (fcc) in as-cast condition along with typical dendritic features. The bulk texture of the as-cast alloy reveals the triclinic sample symmetry and characteristic nature of coarse-grained materials. The alloy exhibits maximum strength ( σ YS and σ UTS) values along the transverse direction. The elongation values are maximum and minimum along the transverse and longitudinal directions, respectively. Tensile fracture surfaces of both the longitudinal and transverse samples display complete ductile fracture features. Two types of slip lines, namely, planar and intersecting, are observed in deformed specimens and the density of slip lines increases with increasing the amount of deformation. The alloy displays moderate in-plane anisotropy ( A IP) and reasonably low anisotropic index ( δ) values, respectively. The instantaneous or work-hardening rate curves portray three typical stages (I through III) along both the longitudinal and transverse directions. The alloy exhibits dislocation-controlled strain hardening during tensile testing, and slip is the predominant deformation mechanism.

  9. Morphological Analysis of Bronchial Arteries and Variants with Computed Tomography Angiography.

    PubMed

    Esparza-Hernández, Claudia Nallely; Ramírez-González, Juan Manuel; Cuéllar-Lozano, Rolando Alberto; Morales-Avalos, Rodolfo; González-Arocha, Carla Sofía; Martínez-González, Brenda; Quiroga-Garza, Alejandro; Pinales-Razo, Ricardo; Elizondo-Riojas, Guillermo; Elizondo-Omaña, Rodrigo Enrique; Guzmán-López, Santos

    2017-01-01

    The aim of our study was to determine the prevalence of anatomical variants of bronchial arteries using computed tomographic angiography in a population of northeastern Mexico. An observational, transversal, descriptive, comparative, retrospective study was performed using 139 imaging studies of Mexican patients in which we evaluated the following parameters from the left and right bronchial arteries: artery origin, branching pattern, arterial ostium, vertebral level of origin, diameter, and mediastinal trajectory. The anatomies of the bronchial arteries were similar in both genders, except distribution for vertebral origin level ( p   0.006) and the diameter ( p   0.013). Left and right arteries were similar, except for the mediastinal trajectory in reference to the esophagus ( p < 0.001) as well as the arterial diameter ( p < 0.001) and lumen diameter.

  10. Wavelet-based algorithm to the evaluation of contrasted hepatocellular carcinoma in CT-images after transarterial chemoembolization.

    PubMed

    Alvarez, Matheus; de Pina, Diana Rodrigues; Romeiro, Fernando Gomes; Duarte, Sérgio Barbosa; Miranda, José Ricardo de Arruda

    2014-07-26

    Hepatocellular carcinoma is a primary tumor of the liver and involves different treatment modalities according to the tumor stage. After local therapies, the tumor evaluation is based on the mRECIST criteria, which involves the measurement of the maximum diameter of the viable lesion. This paper describes a computed methodology to measure through the contrasted area of the lesions the maximum diameter of the tumor by a computational algorithm. 63 computed tomography (CT) slices from 23 patients were assessed. Non-contrasted liver and HCC typical nodules were evaluated, and a virtual phantom was developed for this purpose. Optimization of the algorithm detection and quantification was made using the virtual phantom. After that, we compared the algorithm findings of maximum diameter of the target lesions against radiologist measures. Computed results of the maximum diameter are in good agreement with the results obtained by radiologist evaluation, indicating that the algorithm was able to detect properly the tumor limits. A comparison of the estimated maximum diameter by radiologist versus the algorithm revealed differences on the order of 0.25 cm for large-sized tumors (diameter > 5 cm), whereas agreement lesser than 1.0 cm was found for small-sized tumors. Differences between algorithm and radiologist measures were accurate for small-sized tumors with a trend to a small decrease for tumors greater than 5 cm. Therefore, traditional methods for measuring lesion diameter should be complemented non-subjective measurement methods, which would allow a more correct evaluation of the contrast-enhanced areas of HCC according to the mRECIST criteria.

  11. Three-dimensional force measurements with mandibular overdentures connected to implants by ball-shaped retentive anchors. A clinical study.

    PubMed

    Mericske-Stern, R

    1998-01-01

    The purpose of this in vivo study was to determine maximum and functional forces simultaneously in three dimensions on mandibular implants supporting overdentures. The anchorage system for overdenture connection was the ball-shaped retentive anchor. Five edentulous patients, each with two mandibular ITI implants, were selected as test subjects. A novel miniaturized piezo-electric force transducer was developed for specific use with ITI implants. Force magnitudes and directions were registered under various test conditions by means of electrostatic plotter records. The test modalities were maximum biting in centric occlusion, maximum biting on a bite plate, grinding, and chewing bread. Maximum forces measured in centric occlusion and on the ipsilateral implant when using a bite plate were slightly increased in vertical and backward-forward dimension (z-, y-axis) compared to the lateral-medial direction (x-axis). On the contralateral implant, equally low values were found in all three dimensions. This may be the effect of a nonsplinted anchorage device. With the use of a bite plate, force magnitudes on the ipsilateral implant were significantly higher on the z- and y-axis than mean maximum forces in centric occlusion (P < .001). Chewing and grinding resulted in lower forces compared to maximum biting, particularly in the vertical direction. The transverse force component in backward-forward direction, however, reached magnitudes that exceeded the vertical component by 100% to 300% during chewing function. This chewing pattern had not been observed in previous investigations with bars and telescopes, and therefore appears to be specific for retentive ball anchors. The prevalent or exclusive force direction registered on both implants in the vertical direction was downward under all test conditions. In the transverse direction during maximum biting the forward direction was more frequently registered, while no obvious prevalence of transverse force direction was observed during chewing and grinding.

  12. Pediatric Penile and Glans Anthropometry Nomograms: An Aid in Hypospadias Management.

    PubMed

    Puri, Archana; Sikdar, Satyajit; Prakash, Raghu

    2017-01-01

    To establish pediatric penile and glans anthropometry nomograms. This may be used as a reference model for penile assessment while managing hypospadias. Between October 2012 and September 2013, 263 boys of varying ages (0-16 years) were included in the study. Those with genetic, endocrine disorders, having genital anomaly, undescended testis, neonates, and infants with a nonretractile prepuce, with multiple congenital anomalies and refusal to take part in the study were excluded. Evaluated outcome variables were stretched penile length, glans circumference (GC) at coronal sulcus, glans diameter at coronal sulcus (Gdcl), mid glans diameter, and ventral glans length. Glans ratios were generated by dividing Gdcl by GC. Data were expressed as mean, median, and standard deviation. Correlation between age and variables was evaluated using nonparametric Spearman's rank correlation coefficient. The patients were divided in six age groups, namely 0-1 ( n = 61), 1-3 ( n = 37), 3-5 ( n = 36), 5-7 ( n = 36), 7-12 ( n = 45), and >12 years ( n = 48). Gdcl was the maximum transverse glans diameter and based on it small glans size varied widely from 8.9 to 35.04 mm for various age groups. Although glans anthropometry showed age-related changes, glans ratio remained relatively constant between 0.49 and 0.53 (mean: 0.5 ± 0.051, r = 0.29). All the variables except glans ratio showed a significant positive correlation with age ( r = 0.954-0.98, P < 0.01). Penile anthropometry nomograms provide a reference model for hypospadias. This may aid in (a) objective preoperative assessment of glans size (b) patient selection for preoperative hormonal stimulation (c) provides a yardstick for postoperative cosmesis.

  13. An anatomical study of the intersigmoid fossa and applications for internal hernia surgery.

    PubMed

    Somé, O R; Ndoye, J M; Yohann, R; Nolan, G; Roccia, H; Dakoure, W P; Chaffanjon, P

    2017-03-01

    To improve the knowledge of the morphometry and the surrounding anatomical structures of the intersigmoid fossa and to determine possible surgical applications. Forty eight adult cadavers (29 female and 19 male; mean age 83 years) underwent dissection in the Laboratoire d'Anatomie des Alpes Francaises. Two injections in the right carotid resulted in a total body concentration of formalin of 1.3 %. The study parameters were the dimensions of the intersigmoid fossa orifice and the fossa's relationship to surrounding structures. Data were recorded and analyzed using Microsoft Office Excel (MS Cerp). A Pearson coefficient r was used to examine the correlation between the length of colon and the ISF volume. The intersigmoid fossa was present in 75 % of cases (n = 36). The average dimensions for the transverse diameter, longitudinal diameter, and the depth were, respectively, 20.5 ± 0.2, 20.3 ± 0.13, and 26.8 ± 0.2 mm. The primary and secondary roots bordering this fossa measured on average 59.1 ± 0.1 and 48.3 ± 0.13 mm. In 13.9 % of cases (n = 5), the maximum depth was >40 mm and in 16.7 % of cases (n = 6), one of the diameters of the orifice entry of the fossa was >40 mm. The ureter and external iliac artery were the most frequently encountered structures during the dissection of the fundus of the intersigmoid fossa. The intersigmoid fossa remains present in most of the reported dissections of cadavers. It constitutes an essential landmark in the surgery of the sigmoid colon due to its deep structural relationship with the left ureter and external iliac artery.

  14. 1.9 W continuous-wave single transverse mode emission from 1060 nm edge-emitting lasers with vertically extended lasing area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miah, M. J., E-mail: jarez.miah@tu-berlin.de; Posilovic, K.; Kalosha, V. P.

    2014-10-13

    High-brightness edge-emitting semiconductor lasers having a vertically extended waveguide structure emitting in the 1060 nm range are investigated. Ridge waveguide (RW) lasers with 9 μm stripe width and 2.64 mm cavity length yield highest to date single transverse mode output power for RW lasers in the 1060 nm range. The lasers provide 1.9 W single transverse mode optical power under continuous-wave (cw) operation with narrow beam divergences of 9° in lateral and 14° (full width at half maximum) in vertical direction. The beam quality factor M{sup 2} is less than 1.9 up to 1.9 W optical power. A maximum brightness of 72 MWcm{sup −2}sr{supmore » −1} is obtained. 100 μm wide and 3 mm long unpassivated broad area lasers provide more than 9 W optical power in cw operation.« less

  15. Fast Transverse Instability and Electron Cloud Measurements in Fermilab Recycler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eldred, Jeffery; Adamson, Philip; Capista, David

    2015-03-01

    A new transverse instability is observed that may limit the proton intensity in the Fermilab Recycler. The instability is fast, leading to a beam-abort loss within two hundred turns. The instability primarily affects the first high-intensity batch from the Fermilab Booster in each Recycler cycle. This paper analyzes the dynamical features of the destabilized beam. The instability excites a horizontal betatron oscillation which couples into the vertical motion and also causes transverse emittance growth. This paper describes the feasibility of electron cloud as the mechanism for this instability and presents the first measurements of the electron cloud in the Fermilabmore » Recycler. Direct measurements of the electron cloud are made using a retarding field analyzer (RFA) newly installed in the Fermilab Recycler. Indirect measurements of the electron cloud are made by propagating a microwave carrier signal through the beampipe and analyzing the phase modulation of the signal. The maximum betatron amplitude growth and the maximum electron cloud signal occur during minimums of the bunch length oscillation.« less

  16. Study of the transverse beam motion in the DARHT Phase II accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Yu-Jiuan; Fawley, W M; Houck, T L

    1998-08-20

    The accelerator for the second-axis of the Dual Axis Radiographic Hydrodynamic Test (DARHT) facility will accelerate a 4-kA, 3-MeV, 2--µs long electron current pulse to 20 MeV. The energy variation of the beam within the flat-top portion of the current pulse is (plus or equal to) 0.5%. The performance of the DARHT Phase II radiographic machine requires the transverse beam motion to be much less than the beam spot size which is about 1.5 mm diameter on the x-ray converter. In general, the leading causes of the transverse beam motion in an accelerator are the beam breakup instability (BBU) andmore » the corkscrew motion. We have modeled the transverse beam motion in the DARHT Phase II accelerator with various magnetic tunes and accelerator cell configurations by using the BREAKUP code. The predicted sensitivity of corkscrew motion and BBU growth to different tuning algorithms will be presented.« less

  17. Elastic Moduli and Damping of Vibrational Modes of Aluminum/Silicon Carbide Composite Beams

    NASA Technical Reports Server (NTRS)

    Leidecker, Henning

    1996-01-01

    Elastic and shear moduli were determined for two aluminum matrix composites containing 20 and 40 volume percent discontinuous silicon carbide, respectively, using transverse, longitudinal, and torsional vibrational modes of specimens prepared as thin beams. These moduli are consistent with those determined from stress-strain measurements. The damping factors for these modes were also determined. Thermal properties are used to show that part of the damping of transverse modes is caused by the transverse thermal currents discussed by C. Zener (thermo-elastic damping); this damping is frequency-dependent with a maximum damping factor of approximately 0.002. The remaining damping is frequency-independent, and has roughly similar values in transverse, longitudinal, and torsional modes: approximately 0.0001.

  18. Volumetric Growth of the Liver in the Human Fetus: An Anatomical, Hydrostatic, and Statistical Study

    PubMed Central

    Szpinda, Michał; Paruszewska-Achtel, Monika; Mila-Kierzenkowska, Celestyna; Elminowska-Wenda, Gabriela; Dombek, Małgorzata; Szpinda, Anna; Badura, Mateusz

    2015-01-01

    Using anatomical, hydrostatic, and statistical methods, liver volumes were assessed in 69 human fetuses of both sexes aged 18–30 weeks. No sex differences were found. The median of liver volume achieved by hydrostatic measurements increased from 6.57 cm3 at 18–21 weeks through 14.36 cm3 at 22–25 weeks to 20.77 cm3 at 26–30 weeks, according to the following regression: y = −26.95 + 1.74 × age ± Z  × (−3.15 + 0.27 × age). The median of liver volume calculated indirectly according to the formula liver volume = 0.55 × liver length × liver transverse diameter × liver sagittal diameter increased from 12.41 cm3 at 18–21 weeks through 28.21 cm3 at 22–25 weeks to 49.69 cm3 at 26–30 weeks. There was a strong relationship (r = 0.91, p < 0.001) between the liver volumes achieved by hydrostatic (x) and indirect (y) methods, expressed by y = −0.05 + 2.16x  ± 7.26. The liver volume should be calculated as follows liver volume = 0.26 × liver length × liver transverse diameter × liver sagittal diameter. The age-specific liver volumes are of great relevance in the evaluation of the normal hepatic growth and the early diagnosis of fetal micro- and macrosomias. PMID:26413551

  19. Anatomical dimensions of trachea, main bronchi, subcarinal and bronchial angles in fetuses measured ex vivo.

    PubMed

    Harjeet; Sahni, Daisy; Batra, Yatindra Kumar; Rajeev, Subramanyam

    2008-11-01

    The increasing opportunities to consider fetal intervention in selected cases of life-threatening malformations have necessitated airway management of fetuses with low gestational age. This study is aimed to determine the anatomical dimensions of trachea, main bronchi, subcarinal and bronchial angles and their correlation to age and crown rump length (CRL) in fetuses. Measurements of tracheo-bronchial dimensions including the subcarinal and bronchial angles with the vertical were taken in specimens obtained from 40 fetuses, varying in CRL from 61 to 270 mm. The incidence of different shapes at the upper end of trachea was studied. The subcarinal and angles of main bronchi with the vertical were measured radiographically with 20% barium sulfate, in another group of 21 fetuses varying in CRL from 63 to 129 mm. Forty fetuses (22 males, 18 females) were analyzed for the dimensions based on CRL (61-130 mm; 131-200 mm; 201-270 mm--CRL 1, 2, and 3 respectively). The internal transverse diameter of trachea was found to increase steadily from 1.87 +/- 0.56 to 2.67 +/- 0.7 mm (P < 0.001) and 3.68 +/- 0.39 mm (P < 0.001) with increasing CRL. Similarly the outer transverse and antero-posterior diameter of the trachea increased steadily with age. Tracheal length was found to increase significantly to 17.48 +/- 2.89 mm and 24.17 +/- 2.3 from 12.72 +/- 2.5 mm (P < 0.001). The length of paries membranaceous increased with gestational age. Although the length of bronchi increased significantly and linearly, subcarinal and bronchial angles did not show any significant changes with age. There was no sexual dimorphism in measurements in the fetuses of corresponding CRL. Oval shaped trachea was found in 60% and circular in 40% of fetuses. The measurements of subcarinal and bronchial angles performed by radiology were almost the same as those measured in trachea separated from fetuses. The internal transverse, outer transverse and antero-posterior diameters, length of trachea and bronchi and circumference of trachea, relate in a linear fashion to CRL and age. However, subcarinal and bronchial angles remained constant.

  20. Constructing petal modes from the coherent superposition of Laguerre-Gaussian modes

    NASA Astrophysics Data System (ADS)

    Naidoo, Darryl; Forbes, Andrew; Ait-Ameur, Kamel; Brunel, Marc

    2011-03-01

    An experimental approach in generating Petal-like transverse modes, which are similar to what is seen in porro-prism resonators, has been successfully demonstrated. We hypothesize that the petal-like structures are generated from a coherent superposition of Laguerre-Gaussian modes of zero radial order and opposite azimuthal order. To verify this hypothesis, visually based comparisons such as petal peak to peak diameter and the angle between adjacent petals are drawn between experimental data and simulated data. The beam quality factor of the Petal-like transverse modes and an inner product interaction is also experimentally compared to numerical results.

  1. Study on atomization features of a plain injector in high speed transverse air stream

    NASA Astrophysics Data System (ADS)

    Wan, Jian; Gu, Shanjian; Yang, Maolin; Xiao, Weihui

    1990-04-01

    The atomization features of a plain injector in high-speed transverse air stream were investigated by Malvern. In this investigation, air velocity ranged from 50-150m/s, pressure drop of fuel injector, (1.1 - 4.2) x 10 to the 6th Pa, diameter of orifice, 0.5 - 0.9 mm, axial distance between the injector and the survey plane, 50 - 250 mm. Aviation kerosene was used in all experiments. It was found that the atomization features in high pressure drop of fuel injector were greatly differed from the low pressure drop of fuel injector.

  2. Transverse stresses and modes of failure in tree branches and other beams

    PubMed Central

    Ennos, A. R.; van Casteren, A.

    2010-01-01

    The longitudinal stresses in beams subjected to bending also set up transverse stresses within them; they compress the cross section when the beam's curvature is being increased and stretch it when its curvature is being reduced. Analysis shows that transverse stresses rise to a maximum at the neutral axis and increase with both the bending moment applied and the curvature of the beam. These stresses can qualitatively explain the fracture behaviour of tree branches. Curved ‘hazard beams’ that are being straightened split down the middle because of the low transverse tensile strength of wood. By contrast, straight branches of light wood buckle when they are bent because of its low transverse compressive strength. Branches of denser wood break, but the low transverse tensile strength diverts the crack longitudinally when the fracture has only run half-way across the beam, to produce their characteristic ‘greenstick fracture’. The bones of young mammals and uniaxially reinforced composite beams may also be prone to greenstick fracture because of their lower transverse tensile strength. PMID:20018786

  3. Rapid Confined Mixing Using Transverse Jets Part 2: Multiple Jets

    NASA Astrophysics Data System (ADS)

    Forliti, David; Salazar, David

    2012-11-01

    An experimental study has been conducted at the Air Force Research Laboratory at Edwards Air Force Base to investigate the properties of confined mixing devices that employ transverse jets. The experiment considers the mixing of water with a mixture of water and fluorescein, and planar laser induced fluorescence was used to measure instantaneous mixture fraction distributions in the cross section view. Part one of this study presents the scaling law development and results for a single confined transverse jet. Part two will describe the results of configurations including multiple transverse jets. The different regimes of mixing behavior, ranging from under to overpenetration of the transverse jets, are characterized in terms of a new scaling law parameter presented in part one. The level of unmixedness, a primary metric for mixing device performance, is quantified for different jet diameters, number of jets, and relative flow rates. It is apparent that the addition of a second transverse jet provides enhanced scalar uniformity in the main pipe flow cross section compared to a single jet. Three and six jet configurations also provide highly uniform scalar distributions. Turbulent scalar fluctuation intensities, spectral features, and spatial eigenfunctions using the proper orthogonal decomposition will be presented. Distribution A: Public Release, Public Affairs Clearance Number: 12656.

  4. Sexual dimorphism in foramen magnum dimensions in the South Indian population: A digital submentovertex radiographic study.

    PubMed

    Raikar, Neha Ajit; Meundi, Manasa A; David, Chaya M; Rao, Mahesh Dathu; Jogigowda, Sanjay Chikkarasinakere

    2016-01-01

    Personal identification is a vital arena of forensic investigation, facilitating the search for missing persons. This process of identification is eased by the determination of age, sex, and ethnicity. In situations where there are fragmented and mutilated skeletal remains, sex determination is relatively difficult, and it becomes important to establish the accuracy of individual bones. This study aims to evaluate sexual dimorphism in foramen magnum (FM) dimensions in the South Indian population using digital submentovertex (SMV) radiograph. 150 individuals (75 males and 75 females) were subjected to digital SMV radiography. FM in the resultant image was assessed for longitudinal and transverse diameters, circumference, and area. Also, one particular shape was assigned to each image based on the classification of Chethan et al . of FM shapes. Three qualified oral radiologists performed all the measurements twice within an interval of 10 days. The values obtained for all four parameters were statistically significant and higher in males than in females. The most common morphology of FM was an egg shape while hexagonal was the least common morphology. Circumference was the best indicator of sex followed by area, transverse diameter, and longitudinal diameter. Having achieved a high accuracy of 67.3% with digital SMV radiograph makes it a reliable and reproducible alternative to dry skulls for sex determination.

  5. Quantitative Evaluation of Adult Subglottic Stenosis Using Intraoperative Long-range Optical Coherence Tomography

    PubMed Central

    Sharma, Giriraj K.; Loy, Anthony Chin; Su, Erica; Jing, Joe; Chen, Zhongping; Wong, Brian J-F.; Verma, Sunil

    2016-01-01

    Objectives To determine the feasibility of long-range optical coherence tomography (LR-OCT) as a tool to intraoperatively image and measure the subglottis and trachea during suspension microlaryngoscopy before and after endoscopic treatment of subglottic stenosis (SGS). Methods Long-range optical coherence tomography of the adult subglottis and trachea was performed during suspension microlaryngoscopy before and after endoscopic treatment for SGS. The anteroposterior and transverse diameters, cross-sectional area (CSA), distance from the vocal cords, and length of the SGS were measured using a MATLAB software. Pre-intervention and postintervention airway dimensions were compared. Three-dimensional volumetric airway reconstructions were generated using medical image processing software (MIMICS). Results Intraoperative LR-OCT imaging was performed in 3 patients undergoing endoscopic management of SGS. Statistically significant differences in mean anteroposterior diameter (P < .01), transverse diameter (P < .001), and CSA (P < .001) were noted between pre-intervention and postintervention data. Three-dimensional airway models were viewed in cross-sectional format and via virtual “fly through” bronchoscopy. Conclusions This is the first report of intraoperative LR-OCT of the subglottic and tracheal airway before and after surgical management of SGS in humans. Long-range optical coherence tomography offers a practical means to measure the dimensions of SGS and acquire objective data on the response to endoscopic treatment of SGS. PMID:27354215

  6. High-powered microwave ablation with a small-gauge, gas-cooled antenna: initial ex vivo and in vivo results.

    PubMed

    Lubner, Meghan G; Hinshaw, J Louis; Andreano, Anita; Sampson, Lisa; Lee, Fred T; Brace, Christopher L

    2012-03-01

    To evaluate the performance of a gas-cooled, high-powered microwave system. Investigators performed 54 ablations in ex vivo bovine livers using three devices-a single 17-gauge cooled radiofrequency(RF) electrode; a cluster RF electrode; and a single 17-gauge, gas-cooled microwave (MW) antenna-at three time points (n = 6 at 4 minutes, 12 minutes, and 16 minutes). RF power was applied using impedance-based pulsing with maximum 200 W generator output. MW power of 135 W at 2.45 GHz was delivered continuously. An approved in vivo study was performed using 13 domestic pigs. Hepatic ablations were performed using single applicators and the above-mentioned MW and RF generator systems at treatment times of 2 minutes (n = 7 MW, n = 6 RF), 5 minutes (n = 23 MW, n = 8 RF), 7 minutes (n = 11 MW, n = 6 RF), and 10 minutes (n = 7 MW, n = 9 RF). Mean transverse diameter and length of the ablation zones were compared using analysis of variance (ANOVA) with post-hoc t tests and Wilcoxon rank-sum tests. Single ex vivo MW ablations were larger than single RF ablations at all time points (MW mean diameter range 3.5-4.8 cm 4-16 minutes; RF mean diameter range 2.6-3.1 cm 4-16 minutes) (P < .05). There was no difference in mean diameter between cluster RF and MW ablations (RF 3.3-4.4 cm 4-16 minutes; P = .4-.9). In vivo lesion diameters for MW (and RF) were as follows: 2.6 cm ± 0.72 (RF 1.5 cm ± 0.14), 3.6 cm ± 0.89 (RF 2.0 cm ± 0.4), 3.4 cm ± 0.87 (RF 1.8 cm ± 0.23), and 3.8 cm ± 0.74 (RF 2.1 cm ± 0.3) at 2 minutes, 5 minutes, 7 minutes, and 10 minutes (P < .05 all time points). Gas-cooled, high-powered MW ablation allows the generation of large ablation zones in short times. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  7. Test Operation Procedure (TOP) 01-1-010A Vehicle Test Course Severity (Surface Roughness)

    DTIC Science & Technology

    2017-12-12

    Department of Agriculture (USDA) classifications, respectively. TABLE 10. PARTICLE SIZE CLASSES CLASS SIZE Cobble and Gravel >4.75 mm particle diameter...ABBREVIATIONS. USCS Unified Soil Classification System USDA United States Department of Agriculture UTM Universal Transverse Mercator WNS wave number

  8. 7 CFR 51.1995 - U.S. No. 1.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) Well formed; and, (2) Clean and bright. (3) Free from: (i) Blanks; and, (ii) Broken or split shells. (4... minimum diameter, minimum and maximum diameters, or in accordance with one of the size classifications in Table I. Table I Size classifications Maximum size—Will pass through a round opening of the following...

  9. Electron Beam Misalignment Study of MIG for 42 GHz, 200 kW Gyrotron

    NASA Astrophysics Data System (ADS)

    Sharma, S. K.; Singh, Udaybir; Kumar, Nitin; Sahu, Naveen; Shekhawat, Narendra; Srivastava, Deepak; Alaria, M. K.; Bera, A.; Jain, P. K.; Sinha, A. K.

    2017-10-01

    This paper presents the electron beam misalignment study with respect to cathode position and cathode magnetic field of 42 GHz, 200 kW gyrotron. The performance of gyrotron is affected with the misalignment of cathode position. The simulation results confirm the tolerance of cathode misalignment with respect to the design parameters such as the transverse-to-axial velocity ratio, the maximum transverse velocity spread, etc.

  10. Wind tunnel investigation of three axisymmetric cowls of different lengths at Mach numbers from 0.60 to 0.92

    NASA Technical Reports Server (NTRS)

    Re, Richard J.; Abeyounis, William K.

    1993-01-01

    Pressure distributions on three inlets having different cowl lengths were obtained in the Langley 16-Foot Transonic Tunnel. The cowl diameter ratio (highlight diameter to maximum diameter) was 0.85 and the cowl length ratios (cowl length to maximum diameter) were 0.337, 0.439, and 0.547. The cowls had identical nondimensionalized (with respect to cowl length) external geometry and identical internal geometry. The internal contraction ratio (highlight area to throat area) was 1.250. The inlets had longitudinal rows of static pressure orifices on the top and bottom (external) surfaces and on the contraction (internal) and diffuser surfaces. The afterbody was cylindrical in shape, and its diameter was equal to the maximum diameter of the cowl. Depending on the cowl configuration and free-stream Mach number, the mass-flow ratio varied between 0.27 and 0.87 during the tests. Angle of attack varied from 0 to 4.1 deg at selected Mach numbers and mass-flow ratios, and the Reynolds number varied with the Mach number from 3.2x10(exp 6) to 4.2x10(exp 6) per foot.

  11. Biomechanical comparison of straight DCP and helical plates for fixation of transverse and oblique bone fractures.

    PubMed

    Aksakal, Bunyamin; Gurger, Murat; Say, Yakup; Yilmaz, Erhan

    2014-01-01

    Biomechanical comparison of straight DCP and helical plates for fixation of transversal and oblique tibial bone fractures were analyzed and compared to each other by axial compression, bending and torsion tests. An in vitro osteosynthesis of transverse (TF) and oblique bone fracture (OF) fixations have been analysed on fresh sheep tibias by using the DCP and helical compression plates (HP). Statistically significant differences were found for both DCP and helical plate fixations under axial compression, bending and torsional loads. The strength of fixation systems was in favor of DC plating with exception of the TF-HP fixation group under compression loads and torsional moments. The transvers fracture (TF) stability was found to be higher than that found in oblique fracture (OF) fixed by helical plates (HP). However, under torsional testing, compared to conventional plating, the helical plate fixations provided a higher torsional resistance and strength. The maximum stiffness at axial compression loading and maximum torsional strength was achieved in torsional testing for the TF-HP fixations. From in vitro biomechanical analysis, fracture type and plate fixation system groups showed different responses under different loadings. Consequently, current biomechanical analyses may encourage the usage of helical HP fixations in near future during clinical practice for transverse bone fractures.

  12. Transverse Mode Dynamics of VCSELs Undergoing Current Modulation

    NASA Technical Reports Server (NTRS)

    Goorjian, Peter M.; Ning, C. Z.; Agrawal, Govind

    2000-01-01

    Transverse mode dynamics of a 20-micron-diameter vertical-cavity surface-emitting laser (VCSEL) undergoing gain switching by deep current modulation is studied numerically. The direct current (dc) level is set slightly below threshold and is modulated by a large alternating current (ac). The resulting optical pulse train and transverse-mode patterns are obtained numerically. The ac frequency is varied from 2.5 GHz to 10 GHz, and the ac amplitude is varied from one-half to four times that of the dc level. At high modulation frequencies, a regular pulse train is not generated unless the ac amplitude is large enough. At all modulation frequencies, the transverse spatial profile switches from single-mode to multiple-mode pattern as the ac pumping level is increased. Optical pulse widths vary in the range 5-30 ps. with the pulse width decreasing when either the frequency is increased or the ac amplitude is decreased. The numerical modeling uses an approximation form of the semiconductor Maxwell-Bloch equations. Temporal evolution of the spatial profiles of the laser (and of carrier density) is determined without any assumptions about the type or number of modes. Keywords: VCSELs, current modulation, gain switching, transverse mode dynamics, computational modeling

  13. Applied anatomy of small branches of the portal vein in transverse groove of hepatic hilum.

    PubMed

    Yan, Pei-ning; Tan, Wei-feng; Yang, Xin-wei; Zhang, Chuan-sen; Jiang, Xiao-qing

    2014-12-01

    The objective of this study was to provide the morphological details on small branches of the portal vein in transverse groove of hepatic hilum. According to the surgery significance, the small branches of portal vein in transverse groove of hepatic hilum were named as "Short hepatic portal veins (SHPVs)". SHPVs were minutely dissected in 30 adult cadaveric livers. The number, diameter, length, origin points, and entering liver sites of SHPVs were explored and measured. There were 181 SHPVs in 30 liver specimens, including 46% (83/181) from the left portal vein, 31% (56/181) from the bifurcation, and 23% (42/181) from the right portal vein. At the entering liver sites of SHPVs, 22% (40/181) supplied for segment IV, 9% (17/181) for segment V, 4% (7/181) for segment VI, 23% (41/181) for segment VII, and 42% (76/181) for segment I (caudate lobe). There were 6.0 ± 2.4 branches per liver specimen with range 3-12. The mean diameter of SHPVs was 2.25 ± 0.89 mm. The average length of SHPVs was 4.86 ± 2.12 mm. SHPVs widely existed in each liver specimen. The detailed anatomical study of SHPVs could be useful to avoid damaging the short portal branches during hepatic operations, such as isolated or combined caudate lobectomy.

  14. Evaluation of maxillary growth: is there any difference using relief incision during palatoplasty?

    PubMed

    Maluf, Ivan; Doro, Ubiratan; Fuchs, Taíse; dos Santos, Diego Esteves; dos Santos Sacomam, Franserg; da Silva Freitas, Renato; Roca, Guilherme Berto

    2014-05-01

    Scar retraction due to exposed bone in palatoplasty is the leading cause of constricted maxilla. Modern techniques have focused on minimizing the effects of scarring by reducing the exposure of the bone area. The objective of the study was to compare the palatal mucoperiosteal detachment with minimal lateral incision, followed by their synthesis, with the maintenance of lateral areas for relaxation (similar to the von Langenbeck technique) and evaluate the transversal development of the maxilla. A prospective, randomized study was conducted, in which the molding of the dental arch of 14 pigs in 2 stages (at 1 month and 5 months) was performed. The pigs were divided into 3 groups: group 1 underwent lateral incision of the palate for mucoperiosteal detachment and maintenance of bone exposure; group 2 underwent mucoperiosteal palatal detachment with lateral access and no bone exposure; and group 3, the control animals, did not undergo any surgical procedures. Measurements of the dental arches were compared between the groups to assess differences in the development of the maxillary transverse diameter. There were no animals lost during the study. Group 1 showed greater growth restriction of the transverse diameter of the maxilla (36%) when compared with groups 2 (56%) and 3 (59%). Groups 2 and 3 showed similar transverse maxillary development, with no statistical difference. The technique of mucoperiosteal detachment without lateral relief incision has the advantage of reducing future morbidity of a constricted maxilla. This study demonstrated that the technique described can reduce rates of maxillary underdevelopment, a significant complication inherent in the procedure for palatoplasty. The lateral incisions reduce maxillary growth by approximately 20% as compared with this technique. Level II of evidence.

  15. Management of the high-order mode content in large (40 microm) core photonic bandgap Bragg fiber laser.

    PubMed

    Gaponov, D A; Février, S; Devautour, M; Roy, P; Likhachev, M E; Aleshkina, S S; Salganskii, M Y; Yashkov, M V; Guryanov, A N

    2010-07-01

    Very large-mode-area Yb(3+)-doped single-mode photonic bandgap (PBG) Bragg fiber oscillators are considered. The transverse hole-burning effect is numerically modeled, which helps properly design the PBG cladding and the Yb(3+)-doped region for the high-order mode content to be carefully controlled. A ratio of the Yb(3+)-doped region diameter to the overall core diameter of 40% allows for single-mode emission, even for small spool diameters of 15 cm. Such a fiber was manufactured and subsequently used as the core element of a cw oscillator. Very good beam quality parameter M(2)=1.12 and slope efficiency of 80% were measured. Insensitivity to bending, exemplified by the absence of temporal drift of the beam, was demonstrated for curvature diameter as small as 15 cm.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reister, D.B.

    This paper uses the Pontryagin maximum principle to find time optimal paths for a constant speed unicycle. The time optimal paths consist of sequences of arcs of circles and straight lines. The maximum principle introduced concepts (dual variables, bang-bang solutions, singular solutions, and transversality conditions) that provide important insight into the nature of the time optimal paths. 10 refs., 6 figs.

  17. The Feasibility of Two Screws Anterior Fixation for Type II Odontoid Fracture Among Arabs.

    PubMed

    Marwan, Yousef; Kombar, Osama Rabie; Al-Saeed, Osama; Aleidan, Aljarrah; Samir, Ahmed; Esmaeel, Ali

    2016-06-01

    Retrospective, cross-sectional study. To evaluate the feasibility of two screws anterior fixation of the odontoid process among Arab adults. Anterior screw fixation is the treatment of choice for type II odontoid fractures. In order to perform the procedure safely, the diameter of the odontoid process should be wide enough to allow for the placement of one or two screws. A retrospective review of 156 computed tomography scans of the cervical spine was done. The included patients were Arabs, adults (at least 18 years old), and had no evidence of upper cervical spine trauma, deformity, infection, tumor, or surgery. The minimum external transverse diameter (METD), minimum internal transverse diameter (MITD), minimum external anteroposterior diameter (MEAD), and minimum internal anteroposterior diameter (MIAD) of the odontoid process were measured. A P value of ≤0.05 was considered as the cutoff level of statistical significance. Our study included 94 (60.3%) males and 62 (39.7%) females. The mean age of the subjects was 37.8 ± 16.9 years (range 18-85). The mean values of the METD, MITD, MEAD, and MIAD were 8.7 ± 1.0 mm, 6.0 ± 1.1 mm, 10.3 ± 1.0 mm, and 7.4 ± 1.1 mm, respectively. Men had larger diameters compared to women. This was statistically significant for METD (P = 0.035) and MEAD (P < 0.001). The METD was <9.0 mm in 95 (60.9%) subjects, while the MITD was <8.0 mm in 153 (98.1%) subjects. These findings were not significantly different between males and females. Two screws anterior fixation of type II odontoid fracture is not feasible among the majority of Arabs. 3.

  18. Morphometric study of the two fused primary ossification centers of the clavicle in the human fetus.

    PubMed

    Baumgart, Mariusz; Wiśniewski, Marcin; Grzonkowska, Magdalena; Badura, Mateusz; Dombek, Małgorzata; Małkowski, Bogdan; Szpinda, Michał

    2016-10-01

    A satisfactory understanding of the clavicle development may be contributing to both the diagnosis of its congenital defects and prevention of perinatal damage to the shoulder girdle. This study was carried out to examine the transverse and sagittal diameters, cross-sectional area and volume of the two fused primary ossification centers of the clavicle. Using the methods of CT, digital-image analysis and statistics, the size for two fused primary ossification centers of the clavicle in 42 spontaneously aborted human fetuses at ages of 18-30 weeks was studied. Without any male-female and right-left significant differences, the best fit growth models for two fused primary ossification centers of the clavicle were as follows: y = -31.373 + 15.243 × ln(age) ± 1.424 (R (2) = 0.74) for transverse diameter, y = -7.945 + 3.225 × ln(age) ± 0.262 (R (2) = 0.78), y = -4.503 + 2.007 × ln(age) ± 0.218 (R (2) = 0.68), and y = -4.860 + 2.117 × ln(age) ± 0.200 (R (2) = 0.73) for sagittal diameters of the lateral, middle and medial ends respectively, y = -31.390 + 2.432 × age ± 4.599 (R (2) = 0.78) for cross-sectional area, and y = 28.161 + 0.00017 × (age)(4) ± 15.357 (R (2) = 0.83) for volume. With no sex and laterality differences, the fused primary ossification centers of the clavicle grow logarithmically in both transverse and sagittal diameters, linearly in cross-sectional area, and fourth-degree polynomially in volume. Our normative quantitative findings may be conducive in monitoring normal fetal growth and screening for inherited faults and anomalies of the clavicle in European human fetuses.

  19. Current-induced spin polarization on a Pt surface: A new approach using spin-polarized positron annihilation spectroscopy

    NASA Astrophysics Data System (ADS)

    Kawasuso, A.; Fukaya, Y.; Maekawa, M.; Zhang, H.; Seki, T.; Yoshino, T.; Saitoh, E.; Takanashi, K.

    2013-09-01

    Transversely spin-polarized positrons were injected near Pt and Au surfaces under an applied electric current. The three-photon annihilation of spin-triplet positronium, which was emitted from the surfaces into vacuum, was observed. When the positron spin polarization was perpendicular to the current direction, the maximum asymmetry of the three-photon annihilation intensity was observed upon current reversal for the Pt surfaces, whereas it was significantly reduced for the Au surface. The experimental results suggest that electrons near the Pt surfaces were in-plane and transversely spin-polarized with respect to the direction of the electric current. The maximum electron spin polarization was estimated to be more than 0.01 (1%).

  20. A study of cranial variations based on craniometric indices in a South Indian population.

    PubMed

    Kanchan, Tanuj; Krishan, Kewal; Gupta, Anadi; Acharya, Jenash

    2014-09-01

    Human skull has been the most extensively studied bone for establishing the taxonomies at evolutionary levels. Crania are also the most commonly used skeletal elements in population studies because they are known to be more genetically driven and less affected by environmental factors. The craniofacial indices are considered as clinical anthropometric parameters used in the investigation of craniofacial skeletal deformities and brain development. The present research is an attempt to study the cranial indices in the South Indian population. The sample for the study included 118 dry adult crania. All the osteometric measurements were taken using standard anthropometric instruments, and 3 indices, namely, cranial index, orbital index (OI), and index of foreman magnum (FMI), were calculated. Cranial index is calculated as (maximum cranial breadth / maximum cranial length) × 100, OI as (orbital height / orbital breadth) × 100, and FMI as (transverse diameter / anteroposterior diameter) × 100. The crania were further classified based on these indices. The cranial index ranged between 66.67 and 85.71 (mean, 78.57 [SD, 4.11]), the OI ranged between 68.89 and 102.63 (mean, 84.23 [SD, 6.64]), and the FMI ranged between 68.57 and 96.88 (mean, 79.71 [SD, 6.98]). Cranial index did not show any significant correlation with the OI (r = -0.162, P = 0.081) or the FMI (r = -0.045, P = 0.626). A statistically significant correlation was, however, observed between OI and FMI (r = -0.232, P = 0.012). The current study developed population-specific classification of crania using cranial indices. This craniometric baseline data pertaining to the craniofacial indices may be useful in presurgical planning and the postsurgical evaluation. It may also assist the forensic anthropologists in the categorization of human skulls, which may be an important component in identification of highly decomposed dead bodies and skeletal remains. More such studies need to be conducted to understand the effect of environment and genetics on the cranial shapes in different population groups.

  1. Monolithic fiber laser oscillator with record high power

    NASA Astrophysics Data System (ADS)

    Yang, Baolai; Shi, Chen; Zhang, Hanwei; Ye, Qing; Pi, Haoyang; Tao, Rumao; Wang, Xiaolin; Ma, Pengfei; Leng, Jinyong; Chen, Zilun; Zhou, Pu; Xu, Xiaojun; Chen, Jinbao; Liu, Zejin

    2018-07-01

    With an increasing output power, the power scaling of monolithic fiber laser oscillators faces the severe limitations of stimulated Raman scattering (SRS) and the transverse mode instability (TMI) effect. In this work, we report a high power monolithic fiber laser oscillator with a maximum output power of 5.2 kW, which is realized with a trade-off design between the SRS and TMI. The monolithic fiber laser oscillator is constructed with ytterbium-doped fiber with a core/inner cladding diameter of 25/400 µm and corresponding home-made FBG. High-power 915 nm laser diodes are employed as a pump source and are distributed in a bidirectional-pump configuration. By optimizing the bidirectional pump proportion, the monolithic fiber laser oscillator is scaled up to 5.2 kW with a slope efficiency of ~63%. Operating at 5.2 kW, the intensity of the Raman stokes light is ~22 dB below the signal laser and the beam quality (M2-factor) is ~2.2. To the best of our knowledge, this is a record high power for monolithic fiber laser oscillators.

  2. [A functional orthodontic magnetic appliance (FOMA) after Vardimon. 1. A three-dimensional analysis of the force system of the attractive magnets].

    PubMed

    Bourauel, C; Vardimon, A D; Drescher, D; Schmuth, G P

    1995-09-01

    The functional magnetic system (FMS) is a removable functional appliance which induces mandibular advance by means of mandibular and maxillary magnets in an attracting configuration. The maxillary and mandibular plates are each equipped with 2 cylindrically shaped cobalt-samarium magnets, 4 mm in diameter and 3 mm in height, which are welded into stainless steel housings. The force system of this magnetic configuration was analyzed using the orthodontic measurement and simulation system (OMSS). OMSS simulated the mandibular jaw movements by separating the installed magnets vertically, corresponding to a mouth opening of X = -10 mm, transversally (right excursion, +/left excursion, -) at Y = +/- 10 mm and sagittally (anterior displacement, +/posterior displacement, -) at Z = +/- 10 mm. The resulting 2D and 3D force/displacement diagrams elucidate the outstanding centripetal-spatial orientation characteristics of the functional magnetic appliance in reference to the full overlap brought about by the attraction of the mandibular magnet by the maxillary magnet. The maximum centripetal forces reached a value of approximately FY, max = 0.65 N for the vertical attracting force at full overlap of the mandibular and maxillary magnets (X = 0.55 mm, Y = Z = 0 mm), a value of FY, max = 0.65 N for the medial shearing force at a partial transversal overlap Z = 0, Y = +/- 2 mm and Y = +/- 6 mm), and for the sagittal shearing force a value of FZ, max = 1.2 N at a partial sagittal overlap of the magnets (Y = 0 mm, Z = +/- 2 mm).(ABSTRACT TRUNCATED AT 250 WORDS)

  3. SOME PRACTICAL MODIFICATIONS ON HIGH FREQUENCY ION SOURCES (in Hungarian)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nagy, J.; Gombos, P.

    1962-05-01

    A radiofrequency ion source was constructed for the 800-kv cascade type accelerator and 300-kv neutron generator built in the Institute. Besides the usual transversal magnetic field of 50 gauss, an axial magnetic field of 250 gauss intensity was also applied in the immediate neighborhood of the probe. As a result of this, the service life of the discharge tube was increased by several hundred hours but in comparison with the measurements of other authors the percentage of protons underwent no change. The quartz calyx which was built to surround the probe, contributed considerably to an increase of the service life.more » Measurements concerning the selection of the pre-focusing lens are summarized. With a probe of 1.3-mm canal diameter, a maximum 1.9 ma pre-focused ion current was obtained in H/sub 2/ with a gas consumption of 8 to 10 cm/sup 3//hr, (With a probe of 1.7-mm canal diameter, at a gas consumption of 25 cm/sup 3//hr, 2.7 ma current was obtained.) The total consumption of the ion source amounted to 800 w with prefocusing. The energy-spread of the ion beam was found to be 200 ev. Having built it into the cascade type accelerator 1 ma current was measured on the target at an accelerating voltage of 500 kv, where this amount included the secondary electrons as well. (auth)« less

  4. Black Toenail Sign in MELAS Syndrome.

    PubMed

    Whitehead, Matthew T; Wien, Michael; Lee, Bonmyong; Bass, Nancy; Gropman, Andrea

    2017-10-01

    Mitochondrial encephalopathy with lactic acidosis and stroke-like episodes (MELAS) syndrome is a mitochondrial disorder often causing progressive brain injury that is not confined to large arterial territories. Severe insults ultimately lead to gyral necrosis affecting the cortex and juxtacortical white matter; the neuroimaging correlate is partial gyral signal suppression on T2/FLAIR sequences that resemble black toenails. We aimed to characterize the imaging features and the natural history of MELAS-related gyral necrosis. Databases at two children's hospitals were searched for brain magnetic resonance imaging studies of individuals with MELAS. Examinations with motion artifact and those lacking T2/FLAIR sequences were excluded. The location, the cumulative number, and the maximum transverse diameter of necrotic gyral lesions were assessed using T2-weighted images and T2/FLAIR sequences. Wilcoxon signed-rank test was employed to evaluate the relationship between disease duration and the number of necrotic lesions. One hundred twenty-four examinations from patients with 14 unique MELAS patients (16 ± 3 years) were evaluated. Six of the eight patients who developed brain lesions also developed gyral necroses (mean 13, range 0 to 44). Necrotic lesions varied in maximal diameter from 4 to 25 mm. Cumulative necrotic lesions correlated with disease duration (P < 0.001). The black toenail sign signifying gyral necrosis is a common imaging feature in individuals with MELAS syndrome. The extent of gyral necrosis correlates with disease duration. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Experimental and numerical investigations of heat transfer and thermal efficiency of an infrared gas stove

    NASA Astrophysics Data System (ADS)

    Charoenlerdchanya, A.; Rattanadecho, P.; Keangin, P.

    2018-01-01

    An infrared gas stove is a low-pressure gas stove type and it has higher thermal efficiency than the other domestic cooking stoves. This study considers the computationally determine water and air temperature distributions, water and air velocity distributions and thermal efficiency of the infrared gas stove. The goal of this work is to investigate the effect of various pot diameters i.e. 220 mm, 240 mm and 260 mm on the water and air temperature distributions, water and air velocity distributions and thermal efficiency of the infrared gas stove. The time-dependent heat transfer equation involving diffusion and convection coupled with the time-dependent fluid dynamic equation is implemented and is solved by using the finite element method (FEM). The computer simulation study is validated with an experimental study, which is use standard experiment by LPG test for low-pressure gas stove in households (TIS No. 2312-2549). The findings revealed that the water and air temperature distributions increase with greater heating time, which varies with the three different pot diameters (220 mm, 240 mm and 260 mm). Similarly, the greater heating time, the water and air velocity distributions increase that vary by pot diameters (220, 240 and 260 mm). The maximum water temperature in the case of pot diameter of 220 mm is higher than the maximum water velocity in the case of pot diameters of 240 mm and 260 mm, respectively. However, the maximum air temperature in the case of pot diameter of 260 mm is higher than the maximum water velocity in the case of pot diameters of 240 mm and 220 mm, respectively. The obtained results may provide a basis for improving the energy efficiency of infrared gas stoves and other equipment, including helping to reduce energy consumption.

  6. A continuously variable beam-diameter, high-fluence, Q-switched Nd:YAG laser for tattoo removal: comparison of the maximum beam diameter to a standard 4-mm-diameter treatment beam.

    PubMed

    Bernstein, Eric F; Civiok, Jennifer M

    2013-12-01

    Laser beam diameter affects the depth of laser penetration. Q-switched lasers tend to have smaller maximum spot sizes than other dermatologic lasers, making beam diameter a potentially more significant factor in treatment outcomes. To compare the clinical effect of using the maximum-size treatment beam available for each delivered fluence during laser tattoo removal to a standard 4-mm-diameter treatment beam. Thirteen tattoos were treated in 12 subjects using a Q-switched Nd:YAG laser equipped with a treatment beam diameter that was adjustable in 1 mm increments and a setting that would enable the maximally achievable diameter ("MAX-ON" setting) with any fluence. Tattoos were randomly bisected and treated on one side with the MAX-ON setting and on the contralateral side with a standard 4-mm-diameter spot ("MAX-OFF" setting). Photographs were taken 8 weeks following each treatment and each half-tattoo was evaluated for clearance on a 10-point scale by physicians blinded to the treatment conditions. Tattoo clearance was greater on the side treated with the MAX-ON setting in a statistically significant manner following the 1st through 4th treatments, with the MAX-OFF treatment site approaching the clearance of the MAX-ON treatment site after the 5th and 6th treatments. This high-energy, Q-switched Nd:YAG laser with a continuously variable spot-size safely and effectively removes tattoos, with greater removal when using a larger spot-size. © 2013 Wiley Periodicals, Inc.

  7. Reproduction of the giant jellyfish, Nemopilema nomurai (Scyphozoa: Rhizostomeae), in 2006-2008 as peripherally-transported populations

    NASA Astrophysics Data System (ADS)

    Iguchi, Naoki; Lee, Hye Eun; Yoon, Won Duk; Kim, Suam

    2010-06-01

    This study investigated the sexual maturation process, release of spermatozoa or eggs and oocyte diameter of the rhizostomid medusae Nemopilema nomurai using samples collected from August 2006 to June 2008 from the waters around Korea and Japan, including peripheral areas outside the species’ usual habitat. Immature medusae were observed from June to October only in the western sector of the study area. The onset of spermatozoa and egg release occurred in September and October, respectively, and peaked in December and January. Medusae migrated eastward from source areas with the Tsushima Warm Current, where they formed gametes and spawned. Peak position and maximum oocyte diameter increased as the gonads developed according to the size-frequency distribution of oocytes. No fertilized eggs or embryos were found in the gonads. The correlation was analyzed with bell diameter, maximum oocyte diameter, sampling date, surface water temperature and gonad color to estimate which environmental factors and maturation indices were related to the maturation stage of females. Maturation stage correlated well with maximum oocyte diameter, which correlated negatively with surface water temperature. There was no significant correlation between bell diameter and maturation stage. Therefore, bell diameter was inappropriate for determining maturation index. Sex could not be distinguished clearly by gonad color. However, light pink gonads were more prevalent in males and various deep colors such as orange and brown were more frequent in female medusae.

  8. Correlated diffusion of colloidal particles near a liquid-liquid interface.

    PubMed

    Zhang, Wei; Chen, Song; Li, Na; Zhang, Jia Zheng; Chen, Wei

    2014-01-01

    Optical microscopy and multi-particle tracking are used to investigate the cross-correlated diffusion of quasi two-dimensional colloidal particles near an oil-water interface. The behaviors of the correlated diffusion along longitudinal and transverse direction are asymmetric. It is shown that the characteristic length for longitudinal and transverse correlated diffusion are particle diameter d and the distance z from particle center to the interface, respectively, for large particle separation z. The longitudinal and transverse correlated diffusion coefficient D||(r) and D[perpendicular](r) are independent of the colloidal area fraction n when n < 0.3, which indicates that the hydrodynamic interactions(HIs) among the particles are dominated by HIs through the surrounding fluid for small n. For high area fraction n > 0.4 the power law exponent for the spatial decay of [Formula: see text] begins to decrease, which suggests the HIs are more contributed from the 2D particle monolayer self for large n.

  9. Angle-resolved reflection spectroscopy of high-quality PMMA opal crystal

    NASA Astrophysics Data System (ADS)

    Nemtsev, Ivan V.; Tambasov, Igor A.; Ivanenko, Alexander A.; Zyryanov, Victor Ya.

    2018-02-01

    PMMA opal crystal was prepared by a simple hybrid method, which includes sedimentation, meniscus formation and evaporation. We investigated three surfaces of this crystal by angle-resolved reflective light spectroscopy and SEM study. The angle-resolved reflective measurements were carried out in the 400-1100 nm range. We have determined the high-quality ordered surface of the crystal region. Narrow particle size distribution of the surface has been revealed. The average particle diameter obtained with SEM was nearly 361 nm. The most interesting result was that reflectivity of the surface turned out up to 98% at normal light incidence. Using a fit of dependences of the maximum reflectivity wavelength from an angle based on the Bragg-Snell law, the wavelength of maximum 0° reflectivity, the particle diameter and the fill factor have been determined. For the best surface maximum reflectivity wavelength of a 0° angle was estimated to be 869 nm. The particle diameter and fill factor were calculated as 372 nm and 0.8715, respectively. The diameter obtained by fitting is in excellent agreement with the particle diameter obtained with SEM. The reflectivity maximum is assumed to increase significantly when increasing the fill factor. We believe that using our simple approach to manufacture PMMA opal crystals will significantly increase the fabrication of high-quality photonic crystal templates and thin films.

  10. A diffusive atmospheric pressure glow discharge in a coaxial pin-to-ring gap with a transverse magnetic field

    NASA Astrophysics Data System (ADS)

    Wang, YongSheng; Ding, WeiDong; Yan, JiaQi; Wang, YaNan

    2017-09-01

    Atmospheric pressure glow discharge (APGD) has been widely used in the industrial field. The industrial applications are based on achieving stable and diffusive APGD in a relatively large space. The existing sources only achieved stable and diffusive APGD between a short inter-electrode distance within 5 millimeters. In this paper, the effect of a transverse stationary magnetic field on the diffusion of filamentary APGD was studied in a pin-to-ring coaxial gap. The APGD was driven by a high-voltage resonant power supply, and the stationary magnetic field was supplied by a permanent magnet. The stable and diffusive APGD was achieved in the circular area, which diameter was 20 millimeters. The experimental results revealed that more collision ionization occurred and the plasma was distributed diffusively in the discharge gap by applying the external transverse magnetic field. Besides, it is likely to obtain more stable and diffusive APGD in the coaxial pin-to-ring discharge gap when adjusting the input voltage, transverse magnetic flux density and resonant frequency of the power supply.

  11. Classification of Kiwifruit Grades Based on Fruit Shape Using a Single Camera

    PubMed Central

    Fu, Longsheng; Sun, Shipeng; Li, Rui; Wang, Shaojin

    2016-01-01

    This study aims to demonstrate the feasibility for classifying kiwifruit into shape grades by adding a single camera to current Chinese sorting lines equipped with weight sensors. Image processing methods are employed to calculate fruit length, maximum diameter of the equatorial section, and projected area. A stepwise multiple linear regression method is applied to select significant variables for predicting minimum diameter of the equatorial section and volume and to establish corresponding estimation models. Results show that length, maximum diameter of the equatorial section and weight are selected to predict the minimum diameter of the equatorial section, with the coefficient of determination of only 0.82 when compared to manual measurements. Weight and length are then selected to estimate the volume, which is in good agreement with the measured one with the coefficient of determination of 0.98. Fruit classification based on the estimated minimum diameter of the equatorial section achieves a low success rate of 84.6%, which is significantly improved using a linear combination of the length/maximum diameter of the equatorial section and projected area/length ratios, reaching 98.3%. Thus, it is possible for Chinese kiwifruit sorting lines to reach international standards of grading kiwifruit on fruit shape classification by adding a single camera. PMID:27376292

  12. 7 CFR 51.1310 - Sizing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... package. The number of pears in the box shall not vary more than 3 from the number indicated on the box. (b) When the numerical count is marked on western standard pear boxes the pears shall not vary more than three-eighths inch in their transverse diameter for counts 120 or less; one-fourth inch for counts...

  13. 7 CFR 51.1310 - Sizing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... box shall not vary more than 3 from the number indicated on the box. (b) When the numerical count is marked on western standard pear boxes the pears shall not vary more than three-eighths inch in their transverse diameter for counts 120 or less; one-fourth inch for counts 135 to 180, inclusive; and three...

  14. 7 CFR 51.1310 - Sizing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... box shall not vary more than 3 from the number indicated on the box. (b) When the numerical count is marked on western standard pear boxes the pears shall not vary more than three-eighths inch in their transverse diameter for counts 120 or less; one-fourth inch for counts 135 to 180, inclusive; and three...

  15. 7 CFR 51.1269 - Sizing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... pears in the box shall not vary more than 3 from the number indicated on the box. (b) When the numerical count is marked on western standard pear boxes the pears shall not vary more than three-eighths inch in their transverse diameter for counts 120 or less; one-fourth inch for counts 135 to 180, inclusive; and...

  16. 7 CFR 51.1310 - Sizing.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... package. The number of pears in the box shall not vary more than 3 from the number indicated on the box. (b) When the numerical count is marked on western standard pear boxes the pears shall not vary more than three-eighths inch in their transverse diameter for counts 120 or less; one-fourth inch for counts...

  17. 7 CFR 51.1269 - Sizing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... pears in the box shall not vary more than 3 from the number indicated on the box. (b) When the numerical count is marked on western standard pear boxes the pears shall not vary more than three-eighths inch in their transverse diameter for counts 120 or less; one-fourth inch for counts 135 to 180, inclusive; and...

  18. 7 CFR 51.1269 - Sizing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... indicated on the package. The number of pears in the box shall not vary more than 3 from the number indicated on the box. (b) When the numerical count is marked on western standard pear boxes the pears shall not vary more than three-eighths inch in their transverse diameter for counts 120 or less; one-fourth...

  19. 7 CFR 51.1269 - Sizing.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... indicated on the package. The number of pears in the box shall not vary more than 3 from the number indicated on the box. (b) When the numerical count is marked on western standard pear boxes the pears shall not vary more than three-eighths inch in their transverse diameter for counts 120 or less; one-fourth...

  20. Transverse Anderson Localization in Disordered Glass Optical Fibers: A Review.

    PubMed

    Mafi, Arash; Karbasi, Salman; Koch, Karl W; Hawkins, Thomas; Ballato, John

    2014-07-28

    Disordered optical fibers show novel waveguiding properties that can be used for various device applications, such as beam-multiplexed optical communications and endoscopic image transport. The strong transverse scattering from the transversely disordered optical fibers results in transversely confined beams that can freely propagate in the longitudinal direction, similar to conventional optical fibers, with the advantage that any point in the cross section of the fiber can be used for beam transport. For beam multiplexing and imaging applications, it is highly desirable to make the localized beam radius as small as possible. This requires large refractive index differences between the materials that define the random features in the disordered fiber. Here, disordered glass-air fibers are briefly reviewed, where randomly placed airholes in a glass matrix provide the sufficiently large refractive index difference of 0.5 for strong random transverse scattering. The main future challenge for the fabrication of an optimally disordered glass-air fibers is to increase the fill-fraction of airholes to nearly 50% for maximum beam confinement.

  1. Transverse Anderson Localization in Disordered Glass Optical Fibers: A Review

    PubMed Central

    Mafi, Arash; Karbasi, Salman; Koch, Karl W.; Hawkins, Thomas; Ballato, John

    2014-01-01

    Disordered optical fibers show novel waveguiding properties that can be used for various device applications, such as beam-multiplexed optical communications and endoscopic image transport. The strong transverse scattering from the transversely disordered optical fibers results in transversely confined beams that can freely propagate in the longitudinal direction, similar to conventional optical fibers, with the advantage that any point in the cross section of the fiber can be used for beam transport. For beam multiplexing and imaging applications, it is highly desirable to make the localized beam radius as small as possible. This requires large refractive index differences between the materials that define the random features in the disordered fiber. Here, disordered glass-air fibers are briefly reviewed, where randomly placed airholes in a glass matrix provide the sufficiently large refractive index difference of 0.5 for strong random transverse scattering. The main future challenge for the fabrication of an optimally disordered glass-air fibers is to increase the fill-fraction of airholes to nearly 50% for maximum beam confinement. PMID:28788142

  2. Maximum current density and beam brightness achievable by laser-driven electron sources

    NASA Astrophysics Data System (ADS)

    Filippetto, D.; Musumeci, P.; Zolotorev, M.; Stupakov, G.

    2014-02-01

    This paper discusses the extension to different electron beam aspect ratio of the Child-Langmuir law for the maximum achievable current density in electron guns. Using a simple model, we derive quantitative formulas in good agreement with simulation codes. The new scaling laws for the peak current density of temporally long and transversely narrow initial beam distributions can be used to estimate the maximum beam brightness and suggest new paths for injector optimization.

  3. Heat Transfer to Bodies in a High-speed Rarified-Gas Stream

    NASA Technical Reports Server (NTRS)

    Stalder, Jackson R; Goodwin, Glen; Creager, Marcus O

    1952-01-01

    Report presents the results of an investigation to determine the equilibrium temperature and heat-transfer coefficients for transverse cylinders in a high-speed stream of rarefied gas measured over a range of Knudsen numbers (ratio of molecular-mean-free path to cylinder diameter) from 0.025 to 11.8 and for Mach numbers from 2.0 to 3.3. The range of free-stream Reynolds numbers was from 0.28 to 203. The models tested were 0.0010-, 0.0050-, 0.030-, 0.051-, 0.080-, and 0.126-inch -diameter cylinders held normal to the stream.

  4. Diagnostic accuracy of maternal anthropometric measurements as predictors for dystocia in nulliparous women

    PubMed Central

    Alijahan, Rahele; Kordi, Masoumeh; Poorjavad, Munira; Ebrahimzadeh, Saeed

    2014-01-01

    Background: Dystocia is one of the important causes of maternal morbidity and mortality in low-income countries. This study was aimed to determine the diagnostic accuracy of maternal anthropometric measurements as predictors for dystocia in nulliparous women. Materials and Methods: This prospective cohort study was conducted on 447 nulliparous women who referred to Omolbanin hospital. Several maternal anthropometric measurements such as height, transverse and vertical diameters of Michaelis sacral rhomboid area, foot length, head circumference, vertebral and lower limb length, symphysio-fundal height, and abdominal girth were taken in cervical dilatation ≤ 5 cm. Labor progression was controlled by a researcher blind to these measurements. After delivery, the accuracy of individual and combined measurements in prediction of dystocia was analyzed. Dystocia was defined as cesarean section and vacuum or forceps delivery for abnormal progress of labor (cervical dilatation less than 1 cm/h in the active phase for 2 h, and during the second stage, beyond 2 h or fetal head descend less than 1 cm/h). Results: Among the different anthropometric measurements, transverse diameter of the Michaelis sacral rhomboid area ≤9.6 cm, maternal height ≤ 155 cm, height to symphysio-fundal height ratio ≤4.7, lower limb length ≤78 cm, and head circumference to height ratio ≥ 35.05 with accuracy of 81.2%, 68.2%, 65.5%, 63.3%, and 61.5%, respectively, were better predictors. The best predictor was obtained by combination of maternal height ≤155 cm or the transverse diameter of the Michaelis sacral rhomboid area ≤9.6 cm and Johnson's formula estimated fetal weight ≥3255 g, with an accuracy of 90.5%, sensitivity of 70%, and specificity of 93.7%. Conclusions: Combination of other anthropometric measurements and estimated fetal weight with maternal height in comparison to maternal height alone leads to a better predictor for dystocia. PMID:24554954

  5. Diagnostic accuracy of maternal anthropometric measurements as predictors for dystocia in nulliparous women.

    PubMed

    Alijahan, Rahele; Kordi, Masoumeh; Poorjavad, Munira; Ebrahimzadeh, Saeed

    2014-01-01

    Dystocia is one of the important causes of maternal morbidity and mortality in low-income countries. This study was aimed to determine the diagnostic accuracy of maternal anthropometric measurements as predictors for dystocia in nulliparous women. This prospective cohort study was conducted on 447 nulliparous women who referred to Omolbanin hospital. Several maternal anthropometric measurements such as height, transverse and vertical diameters of Michaelis sacral rhomboid area, foot length, head circumference, vertebral and lower limb length, symphysio-fundal height, and abdominal girth were taken in cervical dilatation ≤ 5 cm. Labor progression was controlled by a researcher blind to these measurements. After delivery, the accuracy of individual and combined measurements in prediction of dystocia was analyzed. Dystocia was defined as cesarean section and vacuum or forceps delivery for abnormal progress of labor (cervical dilatation less than 1 cm/h in the active phase for 2 h, and during the second stage, beyond 2 h or fetal head descend less than 1 cm/h). Among the different anthropometric measurements, transverse diameter of the Michaelis sacral rhomboid area ≤9.6 cm, maternal height ≤ 155 cm, height to symphysio-fundal height ratio ≤4.7, lower limb length ≤78 cm, and head circumference to height ratio ≥ 35.05 with accuracy of 81.2%, 68.2%, 65.5%, 63.3%, and 61.5%, respectively, were better predictors. The best predictor was obtained by combination of maternal height ≤155 cm or the transverse diameter of the Michaelis sacral rhomboid area ≤9.6 cm and Johnson's formula estimated fetal weight ≥3255 g, with an accuracy of 90.5%, sensitivity of 70%, and specificity of 93.7%. Combination of other anthropometric measurements and estimated fetal weight with maternal height in comparison to maternal height alone leads to a better predictor for dystocia.

  6. A new thermal model for bone drilling with applications to orthopaedic surgery.

    PubMed

    Lee, JuEun; Rabin, Yoed; Ozdoganlar, O Burak

    2011-12-01

    This paper presents a new thermal model for bone drilling with applications to orthopaedic surgery. The new model combines a unique heat-balance equation for the system of the drill bit and the chip stream, an ordinary heat diffusion equation for the bone, and heat generation at the drill tip, arising from the cutting process and friction. Modeling of the drill bit-chip stream system assumes an axial temperature distribution and a lumped heat capacity effect in the transverse cross-section. The new model is solved numerically using a tailor-made finite-difference scheme for the drill bit-chip stream system, coupled with a classic finite-difference method for the bone. The theoretical investigation addresses the significance of heat transfer between the drill bit and the bone, heat convection from the drill bit to the surroundings, and the effect of the initial temperature of the drill bit on the developing thermal field. Using the new model, a parametric study on the effects of machining conditions and drill-bit geometries on the resulting temperature field in the bone and the drill bit is presented. Results of this study indicate that: (1) the maximum temperature in the bone decreases with increased chip flow; (2) the transient temperature distribution is strongly influenced by the initial temperature; (3) the continued cooling (irrigation) of the drill bit reduces the maximum temperature even when the tip is distant from the cooled portion of the drill bit; and (4) the maximum temperature increases with increasing spindle speed, increasing feed rate, decreasing drill-bit diameter, increasing point angle, and decreasing helix angle. The model is expected to be useful in determination of optimum drilling conditions and drill-bit geometries. Copyright © 2011. Published by Elsevier Ltd.

  7. An AC modulated near infrared gain calibration system for a "Violin-Mode" transimpedance amplifier, intended for advanced LIGO suspensions.

    PubMed

    Lockerbie, N A; Tokmakov, K V

    2016-07-01

    The background to this work was a prototype shadow sensor, which was designed for retro-fitting to an advanced LIGO (Laser Interferometer Gravitational wave Observatory) test-mass/mirror suspension, in which a 40 kg test-mass/mirror is suspended by four approximately 600 mm long by 0.4 mm diameter fused-silica suspension fibres. The shadow sensor comprised a LED source of Near InfraRed (NIR) radiation, and a "tall-thin" rectangular silicon photodiode detector, which together were to bracket the fibre under test. The photodiode was positioned so as to be sensitive (primarily) to transverse "Violin-Mode" vibrations of such a fibre, via the oscillatory movement of the shadow cast by the fibre, as this moved across the face of the detector. In this prototype shadow sensing system the photodiode was interfaced to a purpose-built transimpedance amplifier, this having both AC and DC outputs. A quasi-static calibration was made of the sensor's DC responsivity, i.e., incremental rate of change of output voltage versus fibre position, by slowly scanning a fused-silica fibre sample transversely through the illuminating beam. The work reported here concerns the determination of the sensor's more important AC (Violin-Mode) responsivity. Recognition of the correspondence between direct AC modulation of the source, and actual Violin-Mode signals, and of the transformative role of the AC/DC gain ratio for the amplifier, at any modulation frequency, f, resulted in the construction of the AC/DC calibration source described here. A method for determining in practice the transimpedance AC/DC gain ratio of the photodiode and amplifier, using this source, is illustrated by a specific numerical example, and the gain ratio for the prototype sensing system is reported over the frequency range 1 Hz-300 kHz. In fact, a maximum DC responsivity of 1.26 kV.m(-1) was measured using the prototype photodiode sensor and amplifier discussed here. Therefore, the measured AC/DC transimpedance gain ratio of 922.5 for this sensor, at 500 Hz, translated into a maximum Violin-Mode (AC) responsivity of (1.16 ± 0.05) MV m(-1), at that frequency.

  8. Morphometric Study of Clavicular Facet of Coracoclavicular Joint in Adult Indian Population

    PubMed Central

    Mahajan, Anita; Vasudeva, Neelam

    2016-01-01

    Introduction Anthropologists have used Coracoclavicular Joint (CCJ), a non-metric anatomical variant in population, as a marker for population migration from prehistoric times to present. Aim The aim of this osteological study was to determine the incidence and morphometry of articular facet of CCJ on conoid tubercle of clavicle in Indian population, as Indian studies are scanty and incomplete. Materials and Methods The study was done on 144 adult human clavicles (76 right and 68 left; 93 males and 51 females) collected from osteology museum in Department of Anatomy, Maulana Azad Medical College, New Delhi, India. The presence of articular facet on the conoid tubercle was determined and Maximum Antero-Posterior (MAPD) and maximum transverse diameter (MTD) was measured by digital vernier calliper. The incidence was compared on the basis of sex, side and with other osteological studies in the world. Statistical analysis was done using the Chi-Square test for nominal categorical data and student’s t-test for normally distributed continuous variables in Microsoft Excel 2007 to assess the relationship between the examined variables. Results Articular facet on conoid tubercle was found in 8 cases (5.6%). Seven (9.2%) were present on the right side and one (1.5%) on the left side. Seven cases (7.5%) were present in males and one case (2%) was found in females. The facets were generally oval, with MAPD and MTD of 12.28 and 17.17 mm respectively. A significant side variation was present with right sided facet being more common. The left sided facet was more transversely elongated than right. In males, the facets were more elongated antero-posteriorly than in females. Conclusion The Indian population showed an incidence of 5.6%, which was comparable to other ethnic groups in world population. The morphometric and side differences could be attributed to the occupational factors and range of movements associated with the CCJ. The CCJ should be borne in mind as a differential diagnosis for thoracic outlet syndrome and in general for shoulder pain. PMID:27190785

  9. Characterization of copper and nichrome wires for safety fuse

    NASA Astrophysics Data System (ADS)

    Murdani, E.

    2016-11-01

    Fuse is an important component of an electrical circuit to limiting the current through the electrical circuit for electrical equipment safety. Safety fuses are made of a conductor such as copper and nichrome wires. The aim of this research was to determine the maximum current that can flow in the conductor wires (copper and nichrome). In the experiment used copper and nichrome wires by varying the length of wires (0.2 cm to 20 cm) and diameter of wires (0.1, 0.2, 0.3, 0.4 and 0.5) mm until maximum current reached that marked by melted or broken wire. From this experiment, it will be obtained the dependences data of maximum current to the length and diameter of wires. All data are plotted and it's known as a standard curve. The standard curve will provide an alternative choice of replacing fuse wire according to the maximum current requirement, including the wire type (copper and nichrome wires) and wire dimensions (length and diameter of wire).

  10. Composition and diameter modulation of magnetic nanowire arrays fabricated by a novel approach

    NASA Astrophysics Data System (ADS)

    Shaker Salem, Mohamed; Tejo, Felipe; Zierold, Robert; Sergelius, Philip; Montero Moreno, Josep M.; Goerlitz, Detlef; Nielsch, Kornelius; Escrig, Juan

    2018-02-01

    Straight magnetic nanowires composed of nickel and permalloy segments having different diameters are synthesized using a promising approach. This approach involves the controlled electrodeposition of each magnetic material into specially designed diameter-modulated porous alumina templates. Standard alumina templates are exposed to pore widening followed by a protective coating of the pore wall with ultrathin silica and further anodization. Micromagnetic simulations are employed to investigate the process of magnetization reversal in the fabricated nanowires when the magnetic materials exchange their places in the thick and thin segments. It is found that the magnetization reversal occurs by the propagation of transverse domain wall (DW) when the thick segment is composed of permalloy. However, the reversal process proceeds by the propagation of vortex DW when permalloy is located at the thin segment.

  11. Harmonic cavities and the transverse mode-coupling instability driven by a resistive wall

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venturini, M.

    The effect of rf harmonic cavities on the transverse mode-coupling instability (TMCI) is still not very well understood. We offer a fresh perspective on the problem by proposing a new numerical method for mode analysis and investigating a regime of potential interest to the new generation of light sources where resistive wall is the dominant source of transverse impedance. When the harmonic cavities are tuned for maximum flattening of the bunch profile we demonstrate that at vanishing chromaticities the transverse single-bunch motion is unstable at any current, with growth rate that in the relevant range scales as the 6th powermore » of the current. With these assumptions and radiation damping included, we find that for machine parameters typical of 4th-generation light sources the presence of harmonic cavities could reduce the instability current threshold by more than a factor two.« less

  12. Harmonic cavities and the transverse mode-coupling instability driven by a resistive wall

    DOE PAGES

    Venturini, M.

    2018-02-01

    The effect of rf harmonic cavities on the transverse mode-coupling instability (TMCI) is still not very well understood. We offer a fresh perspective on the problem by proposing a new numerical method for mode analysis and investigating a regime of potential interest to the new generation of light sources where resistive wall is the dominant source of transverse impedance. When the harmonic cavities are tuned for maximum flattening of the bunch profile we demonstrate that at vanishing chromaticities the transverse single-bunch motion is unstable at any current, with growth rate that in the relevant range scales as the 6th powermore » of the current. With these assumptions and radiation damping included, we find that for machine parameters typical of 4th-generation light sources the presence of harmonic cavities could reduce the instability current threshold by more than a factor two.« less

  13. Quantum tachyons

    NASA Astrophysics Data System (ADS)

    Tomaschitz, R.

    2005-02-01

    The interaction of superluminal radiation with matter in atomic bound-bound and bound-free transitions is investigated. We study transitions in the relativistic hydrogen atom effected by superluminal quanta. The superluminal radiation field is coupled by minimal substitution to the Dirac equation in a Coulomb potential. We quantize the interaction to obtain the transition matrix for induced and spontaneous superluminal radiation in hydrogen-like ions. The tachyonic photoelectric effect is scrutinized, the cross-sections for ground state ionization by transversal and longitudinal tachyons are derived. We examine the relativistic regime, high electronic ejection energies, as well as the first order correction to the non-relativistic cross-sections. In the ultra-relativistic limit, both the longitudinal and transversal cross-sections are peaked at small but noticeably different scattering angles. In the non-relativistic limit, the longitudinal cross-section has two maxima, and its minimum is located at the transversal maximum. Ionization cross-sections can thus be used to discriminate longitudinal radiation from transversal tachyons and photons.

  14. Apparent dispersion in transient groundwater flow

    USGS Publications Warehouse

    Goode, Daniel J.; Konikow, Leonard F.

    1990-01-01

    This paper investigates the effects of large-scale temporal velocity fluctuations, particularly changes in the direction of flow, on solute spreading in a two-dimensional aquifer. Relations for apparent longitudinal and transverse dispersivity are developed through an analytical solution for dispersion in a fluctuating, quasi-steady uniform flow field, in which storativity is zero. For transient flow, spatial moments are evaluated from numerical solutions. Ignored or unknown transients in the direction of flow primarily act to increase the apparent transverse dispersivity because the longitudinal dispersivity is acting in a direction that is not the assumed flow direction. This increase is a function of the angle between the transient flow vector and the assumed steady state flow direction and the ratio of transverse to longitudinal dispersivity. The maximum effect on transverse dispersivity occurs if storativity is assumed to be zero, such that the flow field responds instantly to boundary condition changes.

  15. Harmonic cavities and the transverse mode-coupling instability driven by a resistive wall

    NASA Astrophysics Data System (ADS)

    Venturini, M.

    2018-02-01

    The effect of rf harmonic cavities on the transverse mode-coupling instability (TMCI) is still not very well understood. We offer a fresh perspective on the problem by proposing a new numerical method for mode analysis and investigating a regime of potential interest to the new generation of light sources where resistive wall is the dominant source of transverse impedance. When the harmonic cavities are tuned for maximum flattening of the bunch profile we demonstrate that at vanishing chromaticities the transverse single-bunch motion is unstable at any current, with growth rate that in the relevant range scales as the 6th power of the current. With these assumptions and radiation damping included, we find that for machine parameters typical of 4th-generation light sources the presence of harmonic cavities could reduce the instability current threshold by more than a factor two.

  16. Generation of a sub-half-wavelength focal spot with purely transverse spin angular momentum

    NASA Astrophysics Data System (ADS)

    Hang, Li; Fu, Jian; Yu, Xiaochang; Wang, Ying; Chen, Peifeng

    2017-11-01

    We theoretically demonstrate that optical focus fields with purely transverse spin angular momentum (SAM) can be obtained when a kind of special incident fields is focused by a high numerical aperture (NA) aplanatic lens (AL). When the incident pupil fields are refracted by an AL, two transverse Cartesian components of the electric fields at the exit pupil plane do not have the same order of sinusoidal or cosinoidal components, resulting in zero longitudinal SAMs of the focal fields. An incident field satisfying above conditions is then proposed. Using the Richard-Wolf vectorial diffraction theory, the energy density and SAM density distributions of the tightly focused beam are calculated and the results clearly validate the proposed theory. In addition, a sub-half-wavelength focal spot with purely transverse SAM can be achieved and a flattop energy density distribution parallel to z-axis can be observed around the maximum energy density point.

  17. Morphology of the Physiological Apical Foramen in Maxillary and Mandibular First Molars

    PubMed Central

    Abarca, J.; Zaror, C.; Monardes, H.; Hermosilla, V.; Muñoz, C.; Cantin, M.

    2015-01-01

    SUMMARY Information regarding the anatomy of the physiological apical foramen is limited. Knowing its diameter and shapes contributes to clinical work, specifically to the cleaning and shaping of the apical third. The aim of this ex vivo study was to determine the minimum and maximum diameters and shape of the physiological apical foramen in the roots of maxillary and mandibular first molars. A descriptive study was conducted on 89 recently extracted first molars. Roots 3–5 mm from the apex were sectioned and prepared for analysis at 40× magnification. The minimum and maximum diameters of each physiological foramen were measured using the program Motic Images plus 2.0 ML. The shape of the foramina, classified as round, oval or irregular, was determined by the difference between the maximum and minimum diameters. A total of 174 physiological foramina were analyzed. The average of the minimum and maximum diameters was between 0.24–0.33 mm in maxillary first molars and between 0.25–0.33 mm in mandibular first molars. In maxillary molars, the most common shape of the foramen was oval (50%), then irregular (32%), then round (18%). In mandibular molars, the oval shape was also the most frequent (59%), followed by irregular (23%) and round (18%). The findings of this study regarding the morphology of physiological apical foramina in first molars make it easier for the operator to choose the appropriately-sized instruments to perform endodontic therapy successfully. PMID:25937698

  18. Morphology of the Physiological Apical Foramen in Maxillary and Mandibular First Molars.

    PubMed

    Abarca, J; Zaror, C; Monardes, H; Hermosilla, V; Muñoz, C; Cantin, M

    2014-06-01

    Information regarding the anatomy of the physiological apical foramen is limited. Knowing its diameter and shapes contributes to clinical work, specifically to the cleaning and shaping of the apical third. The aim of this ex vivo study was to determine the minimum and maximum diameters and shape of the physiological apical foramen in the roots of maxillary and mandibular first molars. A descriptive study was conducted on 89 recently extracted first molars. Roots 3-5 mm from the apex were sectioned and prepared for analysis at 40× magnification. The minimum and maximum diameters of each physiological foramen were measured using the program Motic Images plus 2.0 ML. The shape of the foramina, classified as round, oval or irregular, was determined by the difference between the maximum and minimum diameters. A total of 174 physiological foramina were analyzed. The average of the minimum and maximum diameters was between 0.24-0.33 mm in maxillary first molars and between 0.25-0.33 mm in mandibular first molars. In maxillary molars, the most common shape of the foramen was oval (50%), then irregular (32%), then round (18%). In mandibular molars, the oval shape was also the most frequent (59%), followed by irregular (23%) and round (18%). The findings of this study regarding the morphology of physiological apical foramina in first molars make it easier for the operator to choose the appropriately-sized instruments to perform endodontic therapy successfully.

  19. Nanopore with Transverse Nanoelectrodes for Electrical Characterization and Sequencing of DNA

    PubMed Central

    Gierhart, Brian C.; Howitt, David G.; Chen, Shiahn J.; Zhu, Zhineng; Kotecki, David E.; Smith, Rosemary L.; Collins, Scott D.

    2009-01-01

    A DNA sequencing device which integrates transverse conducting electrodes for the measurement of electrode currents during DNA translocation through a nanopore has been nanofabricated and characterized. A focused electron beam (FEB) milling technique, capable of creating features on the order of 1 nm in diameter, was used to create the nanopore. The device was characterized electrically using gold nanoparticles as an artificial analyte with both DC and AC measurement methods. Single nanoparticle/electrode interaction events were recorded. A low-noise, high-speed transimpedance current amplifier for the detection of nano to picoampere currents at microsecond time scales was designed, fabricated and tested for future integration with the nanopore device. PMID:19584949

  20. Nanopore with Transverse Nanoelectrodes for Electrical Characterization and Sequencing of DNA.

    PubMed

    Gierhart, Brian C; Howitt, David G; Chen, Shiahn J; Zhu, Zhineng; Kotecki, David E; Smith, Rosemary L; Collins, Scott D

    2008-06-16

    A DNA sequencing device which integrates transverse conducting electrodes for the measurement of electrode currents during DNA translocation through a nanopore has been nanofabricated and characterized. A focused electron beam (FEB) milling technique, capable of creating features on the order of 1 nm in diameter, was used to create the nanopore. The device was characterized electrically using gold nanoparticles as an artificial analyte with both DC and AC measurement methods. Single nanoparticle/electrode interaction events were recorded. A low-noise, high-speed transimpedance current amplifier for the detection of nano to picoampere currents at microsecond time scales was designed, fabricated and tested for future integration with the nanopore device.

  1. Modelling of aortic aneurysm and aortic dissection through 3D printing.

    PubMed

    Ho, Daniel; Squelch, Andrew; Sun, Zhonghua

    2017-03-01

    The aim of this study was to assess if the complex anatomy of aortic aneurysm and aortic dissection can be accurately reproduced from a contrast-enhanced computed tomography (CT) scan into a three-dimensional (3D) printed model. Contrast-enhanced cardiac CT scans from two patients were post-processed and produced as 3D printed thoracic aorta models of aortic aneurysm and aortic dissection. The transverse diameter was measured at five anatomical landmarks for both models, compared across three stages: the original contrast-enhanced CT images, the stereolithography (STL) format computerised model prepared for 3D printing and the contrast-enhanced CT of the 3D printed model. For the model with aortic dissection, measurements of the true and false lumen were taken and compared at two points on the descending aorta. Three-dimensional printed models were generated with strong and flexible plastic material with successful replication of anatomical details of aortic structures and pathologies. The mean difference in transverse vessel diameter between the contrast-enhanced CT images before and after 3D printing was 1.0 and 1.2 mm, for the first and second models respectively (standard deviation: 1.0 mm and 0.9 mm). Additionally, for the second model, the mean luminal diameter difference between the 3D printed model and CT images was 0.5 mm. Encouraging results were achieved with regards to reproducing 3D models depicting aortic aneurysm and aortic dissection. Variances in vessel diameter measurement outside a standard deviation of 1 mm tolerance indicate further work is required into the assessment and accuracy of 3D model reproduction. © 2017 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology.

  2. Serial Versus Direct Dilation of Small Diameter Stents Results in a More Predictable and Complete Intentional Transcatheter Stent Fracture: A PICES Bench Testing Study.

    PubMed

    Crystal, Matthew A; Morgan, Gareth J; Danon, Saar; Gray, Robert G; Gruenstein, Daniel H; Gordon, Brent M; Goldstein, Bryan H

    2018-01-01

    Balloon-expandable stents, implanted in infants and children with congenital heart disease (CHD), often require redilation to match somatic growth. Small diameter stents may eventually require longitudinal surgical transection to prevent iatrogenic vascular stenosis. Intentional transcatheter stent fracture (TSF) is an emerging alternative approach to stent transection, but little is known about the optimal stent substrate and best protocol to improve the likelihood of successful TSF. Bench testing was performed with a stent dilation protocol. After recording baseline characteristics, stents were serially or directly dilated using ultra-high-pressure balloons (UHPB) until fracture occurred or further stent dilation was not possible. Stent characteristics recorded were as follows: cell design, metallurgy, mechanism, and uniformity of fracture. Stents tested included bare-metal coronary stents, premounted small diameter stents, and ePTFE-covered small diameter premounted stents. Ninety-four stents representing 9 distinct models were maximally dilated, with 80 (85%) demonstrating evidence of fracture. Comprehensive fracture details were recorded in 64 stents: linear and complete in 34/64 stents (53.1%), linear and incomplete in 9/64 stents (14.1%), transverse/complex and complete in 6/64 stents (9.4%), and transverse/complex and incomplete in 15/64 stents (23.4%). Stent fracture was not accomplished in some stent models secondary to significant shortening, i.e., "napkin-ring" formation. Serial dilation resulted in evidence of fracture in 62/67 (92.5%) stents compared with 18/27 (66.7%) stents in the direct dilation group (p = 0.003). Intentional TSF is feasible in an ex vivo model. Serial dilation more reliably expanded the stent and allowed for ultimate stent fracture, whereas direct large diameter dilation of stents was more likely to generate a "napkin-ring" configuration, which may be more resistant to fracture. In vivo animal and human testing is necessary to better understand the response to attempted TSF for newly developed stents as well as those currently in use.

  3. Ultrasound measurement of inferior vena cava diameters by emergency department nurses.

    PubMed

    De Lorenzo, Robert A; Holbrook-Emmons, Victoria L

    2014-01-01

    Sonographic measurement of the inferior vena cava (IVC) diameter is a potentially important noninvasive estimate of fluid status. We researched whether nurses without prior ultrasonography experience could accurately obtain vena cava diameter measurements on models and subjects in comparison with those obtained by an expert sonographer. The design was a prospective educational study using a pre- and posttest of knowledge and a comparison of imaging performance between a subject and an expert sonographer. The setting was an urban teaching medical center with emergency nurses and a convenience sample of volunteer patients selected from the emergency department (ED). Nurses completed a written survey and a pretest to document prior training and experience in ultrasonography and assess baseline knowledge. A structured training program (3.5 hr in length) was provided over three sessions. Training consisted of didactic presentations, practice on phantoms (manikin models designed to provide the sonographic image of the human body when scanned by a trainee) and classmates, and one volunteer patient in the ED. Each nurse then measured IVC diameters on three different volunteer patients in transverse and longitudinal orientations using frozen images. An expert sonographer, blinded to subject results, performed the same examination. Correlations were determined, and a posttraining written examination was completed and results compared with the pretest using a pair-wise t test. Fourteen nurses, with a mean of 8 years' nursing experience (range = 2-18 years), participated. Nurse-expert R value correlation for the longitudinal orientation was 0.68 (95% confidence interval [CI] [0.35, 0.76]) and 0.59 (95% CI [0.47, 0.81]) for the transverse orientation. Posttest scores improved 8.2 percentage points (95% CI [4.0, 12.4]) from 83.3% to 91.5%. Following a brief training course, nurses with no prior sonography experience show moderately good correlation measuring the IVC diameter as compared with expert measurements, with better performance demonstrated in the longitudinal orientation.

  4. Studies on low-loss coupling of non-node anti-resonant hollow-core fiber and tapered fiber

    NASA Astrophysics Data System (ADS)

    Zhang, Naiqian; Wang, Zefeng; Liu, Wenbo; Xi, Xiaoming

    2017-10-01

    Up to now, near almost optical fiber gas lasers employ/adopt the scheme of free-space coupling, which increases the difficulty to adjust the optical path, and has poor stability. All-fiber structure fiber-gas lasers are important development directions in the future. We established the numerical model of SMF-28 type tapered single-mode fiber and non-node hollow-core fiber. When the SMF-28 type single-mode fiber has a waist diameter of 40μm when the light source is LP01 fundamental mode with 1550nm wavelength, the mode field diameter is the largest. Meanwhile, we simulated that the equivalent mode field diameter of non-node anti-resonant hollow-core fiber is about 75μm at the same 1550nm wavelength light source. Then, we use different waist diameters of SMF-28 type tapered fibers injected to the non-node anti-resonant hollow-core fiber in simulation and experiments. In the scheme of the single-ended low-loss coupling, the simulation results indicate that the best waist diameter of tapered fiber is 40μm, and the calculated maximum coupling efficiency is 83.55%. Meanwhile, the experimental result of maximum coupling efficiency is 80.74% when the best waist diameter of tapered fiber is also 40μm. As for the double-ended low-loss coupling, the calculated maximum coupling efficiency is near 83.38%.

  5. Interosseous Ligament and Transverse Forearm Stability: A Biomechanical Cadaver Study.

    PubMed

    Gutowski, Christina J; Darvish, Kurosh; Ilyas, Asif M; Jones, Christopher M

    2017-02-01

    The interosseous ligament (IOL) is known to be an important longitudinal stabilizer of the forearm. We hypothesize that it may also contribute to transverse stability, with pronosupination tensioning of the radius relative to the ulna. Therefore, when injured, we predict the interosseous space should widen in the transverse plane, enough to be appreciable on plain radiographs. A measurable difference in interosseous space, comparing an injured with an uninjured forearm, can potentially be of diagnostic and clinical value. Ten fresh-frozen cadaver arms (from 5 individuals) were radiographed in 6 different positions of forearm supination, first in an uninjured state and then with the IOL sectioned, both partially (central band only) and completely. The transverse interosseous distance was measured on radiographs using edge detection software and compared using analysis of variance and contrast analysis. The maximum range of pronosupination was also compared before and after injury, using a paired t test. Average maximum supination increased from 84° to 106°, and pronation from 69° to 84°, after the IOL was sectioned completely. Sectioning of the IOL led to a statistically significant increase in the interosseous distance, a minimum of 2 mm, in all but one forearm position. The IOL of the forearm plays an important role in providing transverse stability to the radius and ulna. When the IOL is sectioned, the forearm exhibits increased pronosupination range of motion. Radiographs of bilateral forearms taken in identical rotational position can reliably differentiate between an intact and torn IOL in cadavers. The IOL's stabilizing role during forearm rotation suggests a novel strategy for diagnosing forearm IOL injury using comparative radiographic measurements. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  6. A Score to Identify Patients with Brain Metastases from Colorectal Cancer Who May Benefit from Whole-brain Radiotherapy in Addition to Stereotactic Radiosurgery/Radiotherapy.

    PubMed

    Rades, Dirk; Dziggel, Liesa; Blanck, Oliver; Gebauer, Niklas; Bartscht, Tobias; Schild, Steven E

    2018-05-01

    To design a tool to predict the probability of new cerebral lesions after stereotactic radiosurgery/radiotherapy for patients with 1-3 brain metastases from colorectal cancer. In 21 patients, nine factors were evaluated for freedom from new brain metastases, namely age, gender, Karnofsky performance score (KPS), tumor type, number, maximum total diameter of all lesions and sites of cerebral lesions, extra-cranial metastases, and time from cancer diagnosis to irradiation. Freedom from new lesions was positively associated with KPS of 90-100 (p=0.013); maximum total diameter ≤15 mm showed a trend for positive association (p=0.09). Points were assigned as: KPS 70-80=1 point, KPS 90-100=2 points, maximum diameter ≤15 mm=2 points and maximum diameter >15 mm=1 point. Six-month rates of freedom from new lesions were 29%, 45% and 100% for those with total scores of 2, 3 and 4 points, respectively, with corresponding 12-month rates of 0%, 45% and 100% (p=0.027). This study identified three risk groups regarding new brain metastases after stereotactic irradiation. Patients with 2 points could benefit from additional whole-brain radiotherapy. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  7. Rotating flexible drag mill

    DOEpatents

    Pepper, W.B.

    1984-05-09

    A rotating parachute for decelerating objects travelling through atmosphere at subsonic or supersonic deployment speeds includes a circular canopy having a plurality of circumferentially arranged flexible panels projecting radially from a solid central disk. A slot extends radially between adjacent panels to the outer periphery of the canopy. Upon deployment, the solid disk diverts air radially to rapidly inflate the panels into a position of maximum diameter. Air impinging on the panels adjacent the panel slots rotates the parachute during its descent. Centrifugal force flattens the canopy into a constant maximum diameter during terminal descent for maximum drag and deceleration.

  8. Fetal biometric parameters: Reference charts for a non-selected risk population from Uberaba, Brazil

    PubMed Central

    Peixoto, Alberto Borges; da Cunha Caldas, Taciana Mara Rodrigues; Dulgheroff, Fernando Felix; Martins, Wellington P.

    2017-01-01

    Objective To establish reference charts for fetal biometric parameters in a non-selected risk population from Uberaba, Southeast of Brazil. Methods A retrospective cross-sectional study was performed among 5656 non-selected risk singleton pregnant women between 14 and 41 weeks of gestation. The ultrasound exams were performed during routine visits of second and third trimesters. Biparietal diameter (BPD) was measured at the level of the thalami and cavum septi pellucidi. Head circumference (HC) was calculated by the following formula: HC = 1.62*(BPD + occipital frontal diameter, OFD). Abdominal circumference (AC) was measured using the following formula: AC = (anteroposterior diameter + transverse abdominal diameter) × 1.57. Femur diaphysis length (FDL) was obtained in the longest axis of femur without including the distal femoral epiphysis. The estimated fetal weight (EFW) was obtained by the Hadlock formula. Polynomial regressions were performed to obtain the best-fit model for each fetal biometric parameter as the function of gestational age (GA). Results The mean, standard deviations (SD), minimum and maximum of BPD (cm), HC (cm), AC (cm), FDL (cm) and EFW (g) were 6.9 ± 1.9 (2.3 – 10.5), 24.51 ± 6.61 (9.1 – 36.4), 22.8 ± 7.3 (7.5 – 41.1), 4.9 ± 1.6 (1.2 – 8.1) and 1365 ± 1019 (103 – 4777), respectively. Second-degree polynomial regressions between the evaluated parameters and GA resulted in the following formulas: BPD = –4.044 + 0.540 × GA – 0.0049 × GA2 (R2 = 0.97); HC= –15.420 + 2.024 GA – 0.0199 × GA2 (R2 = 0.98); AC = –9.579 + 1.329 × GA – 0.0055 × GA2 (R2 = 0.97); FDL = –3.778 + 0.416 × GA – 0.0035 × GA2 (R2 = 0.98) and EFW = 916 – 123 × GA + 4.70 × GA2 (R2 = 0.96); respectively. Conclusion Reference charts for the fetal biometric parameters in a non-selected risk population from Uberaba, Southeast of Brazil, were established. PMID:28439425

  9. Fetal biometric parameters: Reference charts for a non-selected risk population from Uberaba, Brazil.

    PubMed

    Peixoto, Alberto Borges; da Cunha Caldas, Taciana Mara Rodrigues; Dulgheroff, Fernando Felix; Martins, Wellington P; Araujo Júnior, Edward

    2017-03-01

    To establish reference charts for fetal biometric parameters in a non-selected risk population from Uberaba, Southeast of Brazil. A retrospective cross-sectional study was performed among 5656 non-selected risk singleton pregnant women between 14 and 41 weeks of gestation. The ultrasound exams were performed during routine visits of second and third trimesters. Biparietal diameter (BPD) was measured at the level of the thalami and cavum septi pellucidi. Head circumference (HC) was calculated by the following formula: HC = 1.62*(BPD + occipital frontal diameter, OFD). Abdominal circumference (AC) was measured using the following formula: AC = (anteroposterior diameter + transverse abdominal diameter) × 1.57. Femur diaphysis length (FDL) was obtained in the longest axis of femur without including the distal femoral epiphysis. The estimated fetal weight (EFW) was obtained by the Hadlock formula. Polynomial regressions were performed to obtain the best-fit model for each fetal biometric parameter as the function of gestational age (GA). The mean, standard deviations ( SD ), minimum and maximum of BPD (cm), HC (cm), AC (cm), FDL (cm) and EFW (g) were 6.9 ± 1.9 (2.3 - 10.5), 24.51 ± 6.61 (9.1 - 36.4), 22.8 ± 7.3 (7.5 - 41.1), 4.9 ± 1.6 (1.2 - 8.1) and 1365 ± 1019 (103 - 4777), respectively. Second-degree polynomial regressions between the evaluated parameters and GA resulted in the following formulas: BPD = -4.044 + 0.540 × GA - 0.0049 × GA 2 ( R 2 = 0.97); HC= -15.420 + 2.024 GA - 0.0199 × GA 2 ( R 2 = 0.98); AC = -9.579 + 1.329 × GA - 0.0055 × GA 2 ( R 2 = 0.97); FDL = -3.778 + 0.416 × GA - 0.0035 × GA 2 ( R 2 = 0.98) and EFW = 916 - 123 × GA + 4.70 × GA 2 ( R 2 = 0.96); respectively. Reference charts for the fetal biometric parameters in a non-selected risk population from Uberaba, Southeast of Brazil, were established.

  10. Droplet impact dynamics for two liquids impinging on anisotropic superhydrophobic surfaces

    NASA Astrophysics Data System (ADS)

    Pearson, John T.; Maynes, Daniel; Webb, Brent W.

    2012-09-01

    Droplet impingement experiments were performed on grooved hydrophobic surfaces with cavity fractions of 0, 80, and 93 % using droplets of water and a 50 %/50 % water/glycerol mixture. The influence of liquid viscosity, cavity fraction, and spreading direction, relative to the surface grooves, is explored qualitatively and quantitatively. The maximum droplet spread diameter, velocity of the rebounding jet, and the time delay between droplet impact and jet emission were characterized for Weber numbers, We, based on droplet impact speed and diameter, up to 500. The unequal shear stresses and contact angles influence the maximum spread diameters in the two primary spread directions. At We > 100, the ratio of the spread diameter along the direction of the grooves to the spread diameter perpendicular to the grooves increases above unity with increasing We. The maximum droplet spread diameter is compared to recent predictive models, and the data reveal differing behavior for the two fluids considered. The results also reveal the existence of very high relative jet velocities in the range 5 ≤ We ≤ 15 for water droplets, while such jets were not observed for the more viscous mixture. Further, in the range 115 ≤ We ≤ 265, the water/glycerol jet formation dynamics are radically different from the water behavior. Most evident is the existence of two-pronged jets, which arise from the anisotropy of the surface and the unequal shear stresses and contact angles that prevail on the surfaces. It is these influences that give rise to differences in the maximum spread diameters in the two primary spread directions. Similar two-pronged jet emission was observed for water over the very narrow range of We from 91 to 96. The issuing jet velocities were also observed to increase with increasing cavity fraction for both fluids and over the entire range of We explored. Lastly, the elapsed time between droplet impact and jet emission decreased with increasing cavity fraction.

  11. Lethal effect of electric fields on isolated ventricular myocytes.

    PubMed

    de Oliveira, Pedro Xavier; Bassani, Rosana Almada; Bassani, José Wilson Magalhães

    2008-11-01

    Defibrillator-type shocks may cause electric and contractile dysfunction. In this study, we determined the relationship between probability of lethal injury and electric field intensity (E in isolated rat ventricular myocytes, with emphasis on field orientation and stimulus waveform. This relationship was sigmoidal with irreversible injury for E > 50 V/cm . During both threshold and lethal stimulation, cells were twofold more sensitive to the field when it was applied longitudinally (versus transversally) to the cell major axis. For a given E, the estimated maximum variation of transmembrane potential (Delta V(max)) was greater for longitudinal stimuli, which might account for the greater sensitivity to the field. Cell death, however, occurred at lower maximum Delta V(max) values for transversal shocks. This might be explained by a less steep spatial decay of transmembrane potential predicted for transversal stimulation, which would possibly result in occurrence of electroporation in a larger membrane area. For the same stimulus duration, cells were less sensitive to field-induced injury when shocks were biphasic (versus monophasic). Ours results indicate that, although significant myocyte death may occur in the E range expected during clinical defibrillation, biphasic shocks are less likely to produce irreversible cell injury.

  12. Observation of enhanced spontaneous emission in dielectrically apertured microcavities

    NASA Astrophysics Data System (ADS)

    Graham, Luke Alan

    The effects of enhanced spontaneous emission are important in determining the low threshold characteristics of oxide confined vertical cavity semiconductor lasers. This enhancement effect increases as Q/V, where Q = λ/Δλ for the cavity and V is the mode volume. In particular we investigate the effects of mode diameter on enhancement in microcavity structures with successively smaller dielectric apertures. These structures were fabricated by etching and back filling with SiO 2 and by lateral steam oxidation. For both cavities, InAlGaAs quantum dot emitters were used in the active region in order to avoid carrier diffusion and recombination at the side walls. Decay data was obtained at 10 K using time resolved photoluminescence of individual microcavities, and arrays. The detector used here is based on a silicon avalanche photodiode operated in ``Geiger'' mode. It provides a resolution of 350 ps and a quantum efficiency of ~1% at a wavelength of 1 μm. For the etched aperture structures we observed enhancement factors as high as 1.4 for the 1 μm diameter cavities with a maximum Q ~ 200. The enhancement is limited by the low Qs induced by etched side wall scattering. For 1 μm apertures fabricated by lateral steam oxidation, a Q of 450 is obtained with an enhancement factor of 2.3. In these devices we show that the enhancement is limited by distribution of quantum dots throughout the aperture region. Dots resonant with the cavity and located along the aperture edge decay more slowly than those in the center, leading to spatial hole burning effects in the decay data. Microcavities with aperture sizes ranging from 1-5 μm and Qs greater than 5000 are also demonstrated. We show 0th and 1 st order mode spacings as a function of aperture size and from this data calculate the transverse optical mode diameter as a function of aperture diameter. We find that the optical mode size becomes larger than the aperture size for diameters of ~2.5 μm and below and that this is correlated with a steep drop in Q for smaller apertures. We also find that the upper limit in cavity Q in these structures appears to come from losses induced by the MgF2/ZnSe e-beam deposited DBRs.

  13. Optimization of post-column reactor radius in capillary high performance liquid chromatography Effect of chromatographic column diameter and particle diameter

    PubMed Central

    Xu, Hongjuan; Weber, Stephen G.

    2006-01-01

    A post-column reactor consisting of a simple open tube (Capillary Taylor Reactor) affects the performance of a capillary LC in two ways: stealing pressure from the column and adding band spreading. The former is a problem for very small radius reactors, while the latter shows itself for large reactor diameters. We derived an equation that defines the observed number of theoretical plates (Nobs) taking into account the two effects stated above. Making some assumptions and asserting certain conditions led to a final equation with a limited number of variables, namely chromatographic column radius, reactor radius and chromatographic particle diameter. The assumptions and conditions are that the van Deemter equation applies, the mass transfer limitation is for intraparticle diffusion in spherical particles, the velocity is at the optimum, the analyte’s retention factor, k′, is zero, the post-column reactor is only long enough to allow complete mixing of reagents and analytes and the maximum operating pressure of the pumping system is used. Optimal ranges of the reactor radius (ar) are obtained by comparing the number of observed theoretical plates (and theoretical plates per time) with and without a reactor. Results show that the acceptable reactor radii depend on column diameter, particle diameter, and maximum available pressure. Optimal ranges of ar become narrower as column diameter increases, particle diameter decreases or the maximum pressure is decreased. When the available pressure is 4000 psi, a Capillary Taylor Reactor with 12 μm radius is suitable for all columns smaller than 150 μm (radius) packed with 2–5 μm particles. For 1 μm packing particles, only columns smaller than 42.5 μm (radius) can be used and the reactor radius needs to be 5 μm. PMID:16494886

  14. Investigation on location dependent detectability in cone beam CT images with uniform and anatomical backgrounds

    NASA Astrophysics Data System (ADS)

    Han, Minah; Baek, Jongduk

    2017-03-01

    We investigate location dependent lesion detectability of cone beam computed tomography images for different background types (i.e., uniform and anatomical), image planes (i.e., transverse and longitudinal) and slice thicknesses. Anatomical backgrounds are generated using a power law spectrum of breast anatomy, 1/f3. Spherical object with a 5mm diameter is used as a signal. CT projection data are acquired by the forward projection of uniform and anatomical backgrounds with and without the signal. Then, projection data are reconstructed using the FDK algorithm. Detectability is evaluated by a channelized Hotelling observer with dense difference-of-Gaussian channels. For uniform background, off-centered images yield higher detectability than iso-centered images for the transverse plane, while for the longitudinal plane, detectability of iso-centered and off-centered images are similar. For anatomical background, off-centered images yield higher detectability for the transverse plane, while iso-centered images yield higher detectability for the longitudinal plane, when the slice thickness is smaller than 1.9mm. The optimal slice thickness is 3.8mm for all tasks, and the transverse plane at the off-center (iso-center and off-center) produces the highest detectability for uniform (anatomical) background.

  15. Intravertebral deformation in idiopathic scoliosis: a transverse plane computer tomographic study.

    PubMed

    Kotwicki, Tomasz; Napiontek, Marek

    2008-03-01

    The scoliotic vertebrae are submitted to (1) the displacement in the 3-dimensional space and (2) the bone remodeling, which results in a 3-dimensional intrinsic vertebral deformation. Both phenomena are most expressed inside the apical zone of the curve and can be measured in a computer tomographic (CT) scan. A comparative study of CT thoracic scans in scoliotic and normal children was performed to provide a better description of the altered anatomy with respect to patomechanism of scoliosis. Twenty-three scoliotic girls, aged 14.3 +/- 2.1 years, a case of a right thoracic curve with a Cobb angle of 60.6 +/- 19.3 degrees, and 24 controls, free of spinal deformity, sex- and age-matched, underwent CT examination of the thorax at the level of Th8 to Th9 vertebra. The rotation angle of the apical vertebra and the sagittal to coronal rib cage diameters ratio were measured. The intravertebral deformation was assessed by measuring the angles between the axis of the whole vertebra and the axes of the spinous or transverse processes. The ratio of sagittal to coronal chest diameter was reduced in scoliosis patients (P < 0.001) and correlated with the Cobb angle. The angle between the axis of vertebra and the spinous process increased (P = 0.008), and its value was positively correlated with the rotation angle of the vertebra (r = 0.78, P < 0.05); however, the rotation was oriented clockwise, whereas the spinous process deviation was counterclockwise. The angle between the spinous and the transverse process revealed greater values on the concave side (P < 0.001), whereas the transverse processes were not deviated from the axis of vertebra (P = 0.469). A constant pattern, previously not described, of the alteration of morphology of the apical vertebra due to the intravertebral bone remodeling was identified. The intravertebral deformation accompanied the displacement of the vertebra with a linear correlation; however, the 2 phenomena were developing in the opposite directions. Level III, cross-sectional study.

  16. Airflow and temperature distribution inside the maxillary sinus: a computational fluid dynamics simulation.

    PubMed

    Zang, Hongrui; Liu, Yingxi; Han, Demin; Zhang, Luo; Wang, Tong; Sun, Xiuzhen; Li, Lifeng

    2012-06-01

    The airflow velocity and flux in maxillary sinuses were much lower than those in the nasal cavity, and the temperature in maxillary sinuses was much higher than the temperature in the middle meatus. With the increase of maximum diameter of the ostium, the above indices changed little. The purpose of the paper was to investigate, first, the flow and temperature distribution inside normal maxillary sinus in inspiration, and second, flow and temperature alteration with the increase of maximum ostium diameter. Three-dimensional models with nasal cavities and bilateral maxillary sinuses were constructed for computational fluid dynamics analysis. Virtual surgeries were implemented for the maxillary ostium, the maximum diameters of which were 8, 10, 12, and 15 mm, respectively. The finite volume method was used for numerical simulation. The indices of velocity, pressure, vector, and temperature were processed and compared between models. The airflow velocity in maxillary sinuses (average velocity 0.062 m/s) was much lower than that in the middle meatus (average velocity 3.26 m/s). With the increase of ostium diameter, airflow characteristics distributed in the maxillary sinuses changed little. The normal temperature in the maxillary sinus remained almost constant at 34°C and changed little with the increase of ostium diameter.

  17. Human Uterine Wall Tension Trajectories and the Onset of Parturition

    PubMed Central

    Sokolowski, Peter; Saison, Francis; Giles, Warwick; McGrath, Shaun; Smith, David; Smith, Julia; Smith, Roger

    2010-01-01

    Uterine wall tension is thought to be an important determinant of the onset of labor in pregnant women. We characterize human uterine wall tension using ultrasound from the second trimester of pregnancy until parturition and compare preterm, term and twin pregnancies. A total of 320 pregnant women were followed from first antenatal visit to delivery during the period 2000–2004 at the John Hunter Hospital, NSW, Australia. The uterine wall thickness, length, anterior-posterior diameter and transverse diameter were determined by serial ultrasounds. Subjects were divided into three groups: women with singleton pregnancies and spontaneous labor onset, either preterm or term and women with twin pregnancies. Intrauterine pressure results from the literature were combined with our data to form trajectories for uterine wall thickness, volume and tension for each woman using the prolate ellipsoid method and the groups were compared at 20, 25 and 30 weeks gestation. Uterine wall tension followed an exponential curve, with results increasing throughout pregnancy with the site of maximum tension on the anterior wall. For those delivering preterm, uterine wall thickness was increased compared with term. For twin pregnancies intrauterine volume was increased compared to singletons (), but wall thickness was not. There was no evidence for increased tension in those delivering preterm or those with twin gestations. These data are not consistent with a role for high uterine wall tension as a causal factor in preterm spontaneous labor in singleton or twin gestations. It seems likely that hormonal differences in multiple gestations are responsible for increased rates of preterm birth in this group rather than increased tension. PMID:20585649

  18. Multiple jet study

    NASA Technical Reports Server (NTRS)

    Walker, R. E.; Kors, D. L.

    1973-01-01

    Test data is presented which allows determination of jet penetration and mixing of multiple cold air jets into a ducted subsonic heated mainstream flow. Jet-to-mainstream momentum flux ratios ranged from 6 to 60. Temperature profile data is presented at various duct locations up to 24 orifice diameters downstream of the plane of jet injection. Except for two configurations, all geometries investigated had a single row of constant diameter orifices located transverse to the main flow direction. Orifice size and spacing between orifices were varied. Both of these were found to have a significant effect on jet penetration and mixing. The best mixing of the hot and cold streams was achieved with duct height.

  19. Aortic arch shape is not associated with hypertensive response to exercise in patients with repaired congenital heart diseases.

    PubMed

    Ntsinjana, Hopewell N; Biglino, Giovanni; Capelli, Claudio; Tann, Oliver; Giardini, Alessandro; Derrick, Graham; Schievano, Silvia; Taylor, Andrew M

    2013-11-12

    Aortic arch geometry is linked to abnormal blood pressure (BP) response to maximum exercise. This study aims to quantitatively assess whether aortic arch geometry plays a role in blood pressure (BP) response to exercise. 60 age- and BSA-matched subjects--20 post-aortic coarctation (CoA) repair, 20 transposition of great arteries post arterial switch operation (ASO) and 20 healthy controls--had a three-dimensional (3D), whole heart magnetic resonance angiography (MRA) at 1.5 Tesla, 3D geometric reconstructions created from the MRA. All subjects underwent cardiopulmonary exercise test on the same day as MRA using an ergometer cycle with manual BP measurements. Geometric analysis and their correlation with BP at peak exercise were assessed. Arch curvature was similarly acute in both the post-CoA and ASO cases [0.05 ± 0.01 vs. 0.05 ± 0.01 (1/mm/m²); p = 1.0] and significantly different to that of normal healthy controls [0.05 ± 0.01 vs. 0.03 ± 0.01 (1/mm/m²), p < 0.001]. Indexed transverse arch cross sectional area were significantly abnormal in the post-CoA cases compared to the ASO cases (117.8 ± 47.7 vs. 221.3 ± 44.6; p < 0.001) and controls (117.8 ± 47.7 vs. 157.5 ± 27.2 mm²; p = 0.003). BP response to peak exercise did not correlate with arch curvature (r = 0.203, p = 0.120), but showed inverse correlation with indexed minimum cross sectional area of transverse arch and isthmus (r = -0.364, p = 0.004), and ratios of minimum arch area/ descending diameter (r = -0.491, p < 0.001). Transverse arch and isthmus hypoplasia, rather than acute arch angulation plays a role in the pathophysiology of BP response to peak exercise following CoA repair.

  20. (2+1) -dimensional stable spatial Raman solitons

    NASA Astrophysics Data System (ADS)

    Shverdin, M. Y.; Yavuz, D. D.; Walker, D. R.

    2004-03-01

    We analyze the formation, propagation, and interaction of stable two-frequency (2+1) -dimensional solitons, formed in a Raman media driven near maximum molecular coherence. The propagating light is trapped in the two transverse dimensions.

  1. A follow-up study of autosomal dominant polycystic kidney disease with intracranial aneurysms using 3.0 T three-dimensional time-of-flight magnetic resonance angiography.

    PubMed

    Jiang, Tao; Wang, Peng; Qian, Yi; Zheng, Xuan; Xiao, Liaoyuan; Yu, Shengqiang; Liu, Shiyuan

    2013-11-01

    Autosomal dominant polycystic kidney disease (ADPKD) patients have an increased risk for intracranial aneurysms (IAs). Our aim was to screen and follow up the unruptured intracranial aneurysms (UIAs) detected by 3.0 T three-dimensional time-of-flight magnetic resonance angiography (3D-TOF MRA) in patients with ADPKD in order to evaluate the growth of UIAs and the value of 3D-TOF MRA. From 2011 to 2012, we followed up UIAs detected in 40 ADPKD patients who had MRA examinations with an interval of at least 36 months. All MRA examinations were performed on a 3T system (Achieva X-Series, Philips Medical Systems) with a Sense-Head-8 receiver head coil. The acquired data sets were transferred to a workstation (EWS, Philips Medical) to perform maximum intensity projection (MIP) and volume rendering (VR) with a specialized software package (Philips Medical). The size of UIAs was determined as the longest diameter in transverse or vertical measurement. UIAs that grew more than 20% were considered as enlarged. Fifty UIAs were found in 40 previously examined ADPKD patients who underwent 3.0 T 3D-TOF MRA follow-ups. No patients ever had treatment before the second examination. The longest diameter of all follow-up UIAs was less than 10mm and mean diameter was 3.64 ± 2.25 mm. UIAs in only 4 patients (10%) were considered as enlarged. None of the 50 IAs in the 40 ADPKD patients ruptured during the MRA follow-up period. 3.0 T 3D-TOF MRA was feasible for UIAs follow-up in ADPKD patients. The chance of enlargement and rupture of UIAs in ADPKD patients was not higher than in the general population. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  2. Predicting liver metastasis of gastrointestinal tract cancer by diffusion-weighted imaging of apparent diffusion coefficient values

    PubMed Central

    Zheng, De-Xian; Meng, Shu-Chun; Liu, Qing-Jun; Li, Chuan-Ting; Shang, Xi-Dan; Zhu, Yu-Seng; Bai, Tian-Jun; Xu, Shi-Ming

    2016-01-01

    AIM: To determine if efficacy of chemotherapy on liver metastasis of gastrointestinal tract cancer can be predicted by apparent diffusion coefficient (ADC) values of diffusion-weighted imaging (DWI). METHODS: In total, 86 patients with liver metastasis of gastrointestinal tract cancer (156 metastatic lesions) diagnosed in our hospital were included in this study. The maximum diameters of these tumors were compared with each other before treatment, 2 wk after treatment, and 12 wk after treatment. Selected patients were classified as the effective group and the ineffective group, depending on the maximum diameter of the tumor after 12 wk of treatment; and the ADC values at different treatment times between the two groups were compared. Spearman rank correlation was used to analyze the relationship between ADC value and tumor diameter. Receiver operating characteristic curve (ROC curve) was used to analyze the ADC values before treatment to predict the patient’s sensitivity and specificity degree of efficacy to the chemotherapy. RESULTS: There was no difference in age between the two groups and in maximum tumor diameter before treatment and 2 wk after treatment. However, after 12 wk of treatment, maximum tumor diameter in the effective group was significantly lower than that in the ineffective group (P < 0.05). Before treatment, ADC values in the ineffective group were significantly higher than those in the effective group (P < 0.05). There was no difference in ADC values between the effective and ineffective groups after 2 and 12 wk of treatment. However, ADC values were significantly higher after 2 and 12 wk of treatment compared to before treatment in the effective group (P < 0.05). Spearman rank correlation analysis showed that ADC value before treatment and the reduced percentage of the maximum tumor diameter after 12 wk of treatment were negatively correlated, while the increase in the percentage of the ADC value 12 wk after treatment and the decrease in the percentage of the maximum tumor diameter were significantly positively correlated. The results of the ROC curve showed that ADC value with a chemotherapy ineffective threshold value of 1.14 × 10-3 mm2/s before treatment had a sensitivity and specificity of 94.3% and 76.7%, respectively. CONCLUSION: DWI ADC values can be used to predict the response of patients with liver metastasis of gastrointestinal tract cancer to chemotherapy with high sensitivity and relatively high specificity. PMID:26973399

  3. Muscle force depends on the amount of transversal muscle loading.

    PubMed

    Siebert, Tobias; Till, Olaf; Stutzig, Norman; Günther, Michael; Blickhan, Reinhard

    2014-06-03

    Skeletal muscles are embedded in an environment of other muscles, connective tissue, and bones, which may transfer transversal forces to the muscle tissue, thereby compressing it. In a recent study we demonstrated that transversal loading of a muscle with 1.3Ncm(-2) reduces maximum isometric force (Fim) and rate of force development by approximately 5% and 25%, respectively. The aim of the present study was to examine the influence of increasing transversal muscle loading on contraction dynamics. Therefore, we performed isometric experiments on rat M. gastrocnemius medialis (n=9) without and with five different transversal loads corresponding to increasing pressures of 1.3Ncm(-2) to 5.3Ncm(-2) at the contact area between muscle and load. Muscle loading was induced by a custom-made plunger which was able to move in transversal direction. Increasing transversal muscle loading resulted in an almost linear decrease in muscle force from 4.8±1.8% to 12.8±2% Fim. Compared to an unloaded isometric contraction, rate of force development decreased from 20.2±4.0% at 1.3Ncm(-2) muscle loading to 34.6±5.7% at 5.3Ncm(-2). Experimental observation of the impact of transversal muscle loading on contraction dynamics may help to better understand muscle tissue properties. Moreover, applying transversal loads to muscles opens a window to analyze three-dimensional muscle force generation. Data presented in this study may be important to develop and validate muscle models which enable simulation of muscle contractions under compression and enlighten the mechanisms behind. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. The psoas muscle transversal diameter predicts mortality in patients with cirrhosis on a waiting list for liver transplantation: A retrospective cohort study.

    PubMed

    Huguet, Audrey; Latournerie, Marianne; Debry, Pauline Houssel; Jezequel, Caroline; Legros, Ludivine; Rayar, Michel; Boudjema, Karim; Guyader, Dominique; Jacquet, Edouard Bardou; Thibault, Ronan

    2018-02-09

    Malnutrition impairs prognosis in liver cirrhosis. Our aims were to determine (1) if transversal (TPTI) and axial (APTI) psoas thickness indices predict mortality in cirrhotic patients and (2) the feasibility and reproducibility of transversal (TDPM) and axial (ADPM) diameters of the psoas muscle measurements. This was a retrospective study. Inclusion criteria included cirrhosis diagnosis, on liver transplantation waiting list, and abdominal computed tomography (CT) scan within the 3 mo preceding list inscription. TDPM and ADPM were measured on a single umbilicus-targeted CT image by non-expert and expert operators. TPTI or APTI (mm/m) were calculated as TDPM or ADPM/height (m). Area under the receiver operating characteristic curve (AUC) and Cox proportional hazard models were assessed. TPTI and APTI interobserver agreement: κ correlation test. A total of 173 patients were included. Low TPTI was associated with increased mortality: AUC = 0.66 (95% confidence interval, 0.51-0.80). TPTI was the only factor associated with mortality (hazard ratio = 0.87, 95% confidence interval 0.76-0.99, P = 0.034). There was an almost perfect interobserver agreement between the two operators: TDPM, κ = 0.97; ADPM, κ = 0.94; P <0.0001. TPTI measured on umbilicus-targeted CT scan before inscription on the waiting list for liver transplantation predicts mortality of cirrhotic patients. TPTI measurement is easy and reliable, even by a non-trained operator, and this is highly feasible in daily clinical practice. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. THERMAL COUPLE FOR MEASURING TEMPERATURE IN A REACTOR

    DOEpatents

    Kanne, W.

    1959-11-24

    A thermocouple device for measuring the temperature of a flowing fluid in a conduit within which is positioned a metallic rod is presented. A thermocouple junction is secured to the rod centrally, and thermal insulating support disks having a diameter greater than the rod are secured to the end portions of the rod and adapted to fit transversely in the conduit.

  6. Permeability of twenty-two small diameter hardwoods growing on southern pine sites

    Treesearch

    E.T. Choong; F.O. Tesoro; F.G. Manwiller

    1974-01-01

    Gas permeability of hardwoods growing on southern pine sites is significantly affected by moisture content in the longitudinal direction. The ratio of permeability in the transverse to longitudinal directions is from 12,000:1 for post oak to over 1,000,000:1 for other oaks, but it is not affected by moisture. Although variation in longitudinal permeability varies...

  7. permeability of twenty-two small diameter hardwoods growing on southern pine sites

    Treesearch

    E.T. Choong; F.O. Tesora

    1974-01-01

    Gas permeability of hardwoods growing on southern pine sites is significantly affected by moisture content in the longitudinal direction. The ratio of permeability in the transverse to longitudinal directions is from 12,000:1 for post oak to over 1,000,000:1 for other oaks, but it is not affected by moisture. Although variation in longitudinal permeability varies...

  8. Size effects on miniature Stirling cycle cryocoolers

    NASA Astrophysics Data System (ADS)

    Yang, Xiaoqin; Chung, J. N.

    2005-08-01

    Size effects on the performance of Stirling cycle cryocoolers were investigated by examining each individual loss associated with the regenerator and combining these effects. For the fixed cycle parameters and given regenerator length scale, it was found that only for a specific range of the hydrodynamic diameter the system can produce net refrigeration and there is an optimum hydraulic diameter at which the maximum net refrigeration is achieved. When the hydraulic diameter is less than the optimum value, the regenerator performance is controlled by the pressure drop loss; when the hydraulic diameter is greater than the optimum value, the system performance is controlled by the thermal losses. It was also found that there exists an optimum ratio between the hydraulic diameter and the length of the regenerator that offers the maximum net refrigeration. As the regenerator length is decreased, the optimum hydraulic diameter-to-length ratio increases; and the system performance is increased that is controlled by the pressure drop loss and heat conduction loss. Choosing appropriate regenerator characteristic sizes in small-scale systems are more critical than in large-scale ones.

  9. Pre-operative predictive factors for gallbladder cholesterol polyps using conventional diagnostic imaging

    PubMed Central

    Choi, Ji-Hoon; Yun, Jung-Won; Kim, Yong-Sung; Lee, Eun-A; Hwang, Sang-Tae; Cho, Yong-Kyun; Kim, Hong-Joo; Park, Jung-Ho; Park, Dong-Il; Sohn, Chong-Il; Jeon, Woo-Kyu; Kim, Byung-Ik; Kim, Hyoung-Ook; Shin, Jun-Ho

    2008-01-01

    AIM: To determine the clinical data that might be useful for differentiating benign from malignant gallbladder (GB) polyps by comparing radiological methods, including abdominal ultrasonography (US) and computed tomography (CT) scanning, with postoperative pathology findings. METHODS: Fifty-nine patients underwent laparoscopic cholecystectomy for a GB polyp of around 10 mm. They were divided into two groups, one with cholesterol polyps and the other with non-cholesterol polyps. Clinical features such as gender, age, symptoms, size and number of polyps, the presence of a GB stone, the radiologically measured maximum diameter of the polyp by US and CT scanning, and the measurements of diameter from postoperative pathology were recorded for comparative analysis. RESULTS: Fifteen of the 41 cases with cholesterol polyps (36.6%) were detected with US but not CT scanning, whereas all 18 non-cholesterol polyps were observed using both methods. In the cholesterol polyp group, the maximum measured diameter of the polyp was smaller by CT scan than by US. Consequently, the discrepancy between those two scanning measurements was greater than for the non-cholesterol polyp group. CONCLUSION: The clinical signs indicative of a cholesterol polyp include: (1) a polyp observed by US but not observable by CT scanning, (2) a smaller diameter on the CT scan compared to US, and (3) a discrepancy in its maximum diameter between US and CT measurements. In addition, US and the CT scan had low accuracy in predicting the polyp diameter compared to that determined by postoperative pathology. PMID:19058309

  10. Pre-operative predictive factors for gallbladder cholesterol polyps using conventional diagnostic imaging.

    PubMed

    Choi, Ji-Hoon; Yun, Jung-Won; Kim, Yong-Sung; Lee, Eun-A; Hwang, Sang-Tae; Cho, Yong-Kyun; Kim, Hong-Joo; Park, Jung-Ho; Park, Dong-Il; Sohn, Chong-Il; Jeon, Woo-Kyu; Kim, Byung-Ik; Kim, Hyoung-Ook; Shin, Jun-Ho

    2008-11-28

    To determine the clinical data that might be useful for differentiating benign from malignant gallbladder (GB) polyps by comparing radiological methods, including abdominal ultrasonography (US) and computed tomography (CT) scanning, with postoperative pathology findings. Fifty-nine patients underwent laparoscopic cholecystectomy for a GB polyp of around 10 mm. They were divided into two groups, one with cholesterol polyps and the other with non-cholesterol polyps. Clinical features such as gender, age, symptoms, size and number of polyps, the presence of a GB stone, the radiologically measured maximum diameter of the polyp by US and CT scanning, and the measurements of diameter from postoperative pathology were recorded for comparative analysis. Fifteen of the 41 cases with cholesterol polyps (36.6%) were detected with US but not CT scanning, whereas all 18 non-cholesterol polyps were observed using both methods. In the cholesterol polyp group, the maximum measured diameter of the polyp was smaller by CT scan than by US. Consequently, the discrepancy between those two scanning measurements was greater than for the non-cholesterol polyp group. The clinical signs indicative of a cholesterol polyp include: (1) a polyp observed by US but not observable by CT scanning, (2) a smaller diameter on the CT scan compared to US, and (3) a discrepancy in its maximum diameter between US and CT measurements. In addition, US and the CT scan had low accuracy in predicting the polyp diameter compared to that determined by postoperative pathology.

  11. [Transverse radioulnar branch of the dorsal ulnar nerve: anatomic description and arthroscopic implications from 45 cadaveric dissections].

    PubMed

    Ehlinger, M; Rapp, E; Cognet, J-M; Clavert, P; Bonnomet, F; Kahn, J-L; Kempf, J-F

    2005-05-01

    We conducted an anatomic study of the transverse branch of the dorsal ulnar nerve to describe its morphology and position in relation to arthroscopic exploration portals. Forty-five non-side-matched anatomic specimens of unknown age and gender were preserved in formol. The dorsal branch of the ulnar nerve was identified and dissected proximally to distally in order to reveal the different terminal branches. The morphometric analysis included measurement of the length and diameter of the transverse branch and measurement of wrist width. We also measured the smallest distance between the transverse branch and the ulnar styloid process, and between the branch and usual arthroscopic portals (4-5, 6R, 6U) in the axis of the forearm. The transverse branch was inconstant. It was found in 12 of the 45 dissection specimens (27%). In two-thirds of the specimens, the branch ran over less than 50% of the wrist width, tangentially to the radiocarpal joint. Mean nerve diameter was 1 mm. It was found 5-6 mm from the ulnar styloid process and was distal to it in 83% of the specimens. The dissections demonstrated two anatomic variants. Type A corresponded to a branch running distally to the ulnar styloid process, parallel to the joint line (10/12 specimens). Type B exhibited a trajectory proximal to the ulnar styloid process, crossing the ulnar head (2/12 specimens). The relations with the arthroscopic portals (4-5, 6R, 6U) showed that the mean distance from the branch to the portal was 3.75 mm for the 4-5 portal (distally in 11/12 specimens), 3.68 mm for the 6R portal (distally in 10/12 specimens), and 4.83 mm for the 6U portal (distally in 7 specimens and proximally in 5). To our knowledge, there has been only one report specifically devoted to this transverse branch. Two other reports simply mention its existence. According to the literature, the transverse branch of the dorsal ulnar nerve occurs in 60-80% of the cases. We found two anatomic variations different than those described in the literature. Based on our findings and data reported previously, we propose a new classification, describing two main types. In Type 1, the transverse branch arises proximally to the ulnar styloid process;type 1A and type IB are described in relation to the direction of the branch. In Type II, the branch arises distally to the ulnar styloid process;type IIA and type IIB again being described in relation to the direction of the branch. On the tangential trajectory over the radiocarpal joint, the morphometric data show a zone of risk described by a rectangle measuring 10 mm wide (6 mm distal and 4 mm proximal to the ulnar styloid process) and covering 50% of the wrist width. The relations with arthroscopic portals describe a zone of risk corresponding to a 5-7 mm radius circle centered on the portals (4-5, 6R, 6U), which includes 83% of the transverse branches.

  12. Optimising the measurement of bruises in children across conventional and cross polarized images using segmentation analysis techniques in Image J, Photoshop and circle diameter measurements.

    PubMed

    Harris, C; Alcock, A; Trefan, L; Nuttall, D; Evans, S T; Maguire, S; Kemp, A M

    2018-02-01

    Bruising is a common abusive injury in children, and it is standard practice to image and measure them, yet there is no current standard for measuring bruise size consistently. We aim to identify the optimal method of measuring photographic images of bruises, including computerised measurement techniques. 24 children aged <11 years (mean age of 6.9, range 2.5-10 years) with a bruise were recruited from the community. Demographics and bruise details were recorded. Each bruise was measured in vivo using a paper measuring tape. Standardised conventional and cross polarized digital images were obtained. The diameter of bruise images were measured by three computer aided measurement techniques: Image J (segmentation with Simple Interactive Object Extraction (maximum Feret diameter), 'Circular Selection Tool' (Circle diameter), & the Photoshop 'ruler' software (Photoshop diameter)). Inter and intra-observer effects were determined by two individuals repeating 11 electronic measurements, and relevant Intraclass Correlation Coefficient's (ICC's) were used to establish reliability. Spearman's rank correlation was used to compare in vivo with computerised measurements; a comparison of measurement techniques across imaging modalities was conducted using Kolmogorov-Smirnov tests. Significance was set at p < 0.05 for all tests. Images were available for 38 bruises in vivo, with 48 bruises visible on cross polarized imaging and 46 on conventional imaging (some bruises interpreted as being single in vivo appeared to be multiple in digital images). Correlation coefficients were >0.5 for all techniques, with maximum Feret diameter and maximum Photoshop diameter on conventional images having the strongest correlation with in vivo measurements. There were significant differences between in vivo and computer-aided measurements, but none between different computer-aided measurement techniques. Overall, computer aided measurements appeared larger than in vivo. Inter- and intra-observer agreement was high for all maximum diameter measurements (ICC's > 0.7). Whilst there are minimal differences between measurements of images obtained, the most consistent results were obtained when conventional images, segmented by Image J Software, were measured with a Feret diameter. This is therefore proposed as a standard for future research, and forensic practice, with the proviso that all computer aided measurements appear larger than in vivo. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  13. Tensile Properties of the Deep Transverse Metatarsal Ligament in Hallux Valgus: A CONSORT-Compliant Article.

    PubMed

    Abdalbary, Sahar Ahmed; Elshaarawy, Ehab A A; Khalid, Bahaa E A

    2016-02-01

    The deep transverse metatarsal ligament (DTML) connects the neighboring2 metatarsal heads and is one of the stabilizers connecting the lateral sesamoid and second metatarsal head. In this study, we aimed to determine the tensile properties of the DTML in normal specimens and to compare these results with hallux valgus specimens. We hypothesized that the tensile properties of the DTML would be different between the 2 groups of specimens.The DTML in the first interspace was dissected from 12 fresh frozen human cadaveric specimens. Six cadavers had bilateral hallux valgus and the other 6 cadavers had normal feet. The initial length (L0) and cross-sectional area (A0) of the DTML were measured using a digital caliper, and tensile tests with load failure were performed using a material testing machine.There were significant between-groups differences in the initial length (L0) P = 0.009 and cross-sectional area (A0) of the DTML P = 0.007. There were also significant between-groups differences for maximum force (N) P = 0.004, maximum distance (mm) P = 0.005, maximum stress (N/mm) P = 0.003, and maximum strain (%) P = 0.006.The DTML is an anatomical structure for which the tensile properties differ in hallux valgus.

  14. ANATOMY OF HELICAL EXTRAGALACTIC JETS: THE CASE OF S5 0836+710

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perucho, M.; Kovalev, Y. Y.; Lobanov, A. P.

    Helical structures are common in extragalactic jets. They are usually attributed in the literature to periodical phenomena in the source (e.g., precession). In this work, we use very long baseline interferometry data of the radio jet in the quasar S5 0836+710 and hypothesize that the ridgeline of helical jets like this corresponds to a pressure maximum in the jet and assume that the helically twisted pressure maximum is the result of a helical wave pattern. For our study, we use observations of the jet in S5 0836+710 at different frequencies and epochs. The results show that the structures observed aremore » physical and not generated artificially by the observing arrays. Our hypothesis that the observed intensity ridgeline can correspond to a helically twisted pressure maximum is confirmed by our observational tests. This interpretation allows us to explain jet misalignment between parsec and kiloparsec scales when the viewing angle is small, and also brings us to the conclusion that high-frequency observations may show only a small region of the jet flow concentrated around the maximum pressure ridgeline observed at low frequencies. Our work provides a potential explanation for the apparent transversal superluminal speeds observed in several extragalactic jets by means of transversal shift of an apparent core position with time.« less

  15. Cold electron beams from cryocooled, alkali antimonide photocathodes

    DOE PAGES

    Cultrera, L.; Karkare, S.; Lee, H.; ...

    2015-11-30

    In this study we report on the generation of cold electron beams using a Cs 3Sb photocathode grown by codeposition of Sb and Cs. By cooling the photocathode to 90 K we demonstrate a significant reduction in the mean transverse energy validating the long-standing speculation that the lattice temperature contributes to limiting the mean transverse energy or intrinsic emittance near the photoemission threshold, opening new frontiers in generating ultrabright beams. At 90 K, we achieve a record low intrinsic emittance of 0.2 μm (rms) per mm of laser spot diameter from an ultrafast (subpicosecond) photocathode with quantum efficiency greater thanmore » 7 × 10 -5 using a visible laser wavelength of 690 nm.« less

  16. Near-field acoustic microbead trapping as remote anchor for single particle manipulation

    NASA Astrophysics Data System (ADS)

    Hwang, Jae Youn; Cheon, Dong Young; Shin, Hyunjune; Kim, Hyun Bin; Lee, Jungwoo

    2015-05-01

    We recently proposed an analytical model of a two-dimensional acoustic trapping of polystyrene beads in the ray acoustics regime, where a bead diameter is larger than the wavelength used. As its experimental validation, this paper demonstrates the transverse (or lateral) trapping of individual polystyrene beads in the near field of focused ultrasound. A 100 μm bead is immobilized on the central beam axis by a focused sound beam from a 30 MHz single element lithium niobate transducer, after being laterally displaced through hundreds of micrometers. Maximum displacement, a longest lateral distance at which a trapped bead can be directed towards the central axis, is thus measured over a discrete frequency range from 24 MHz to 36 MHz. The displacement data are found to be between 323.7 μm and 470.2 μm, depending on the transducer's driving frequency and input voltage amplitude. The experimental results are compared with their corresponding model values, and their relative errors lie between 0.9% and 3.9%. The results suggest that this remote maneuvering technique may be employed to manipulate individual cells through solid microbeads, provoking certain cellular reactions to localized mechanical disturbance without direct contact.

  17. Large-area super-resolution optical imaging by using core-shell microfibers

    NASA Astrophysics Data System (ADS)

    Liu, Cheng-Yang; Lo, Wei-Chieh

    2017-09-01

    We first numerically and experimentally report large-area super-resolution optical imaging achieved by using core-shell microfibers. The particular spatial electromagnetic waves for different core-shell microfibers are studied by using finite-difference time-domain and ray tracing calculations. The focusing properties of photonic nanojets are evaluated in terms of intensity profile and full width at half-maximum along propagation and transversal directions. In experiment, the general optical fiber is chemically etched down to 6 μm diameter and coated with different metallic thin films by using glancing angle deposition. The direct imaging of photonic nanojets for different core-shell microfibers is performed with a scanning optical microscope system. We show that the intensity distribution of a photonic nanojet is highly related to the metallic shell due to the surface plasmon polaritons. Furthermore, large-area super-resolution optical imaging is performed by using different core-shell microfibers placed over the nano-scale grating with 150 nm line width. The core-shell microfiber-assisted imaging is achieved with super-resolution and hundreds of times the field-of-view in contrast to microspheres. The possible applications of these core-shell optical microfibers include real-time large-area micro-fluidics and nano-structure inspections.

  18. High risk of tuberculous infection in North Sulawesi Province of Indonesia.

    PubMed

    Bachtiar, A; Miko, T Y; Machmud, R; Mehta, F; Chadha, V K; Yudarini, P; Loprang, F; Fahmi, S; Jitendra, R

    2009-12-01

    Of all the provinces in Indonesia, the highest tuberculosis (TB) case notification rates are reported from North Sulawesi Province. To estimate the annual risk of tuberculous infection (ARTI) among schoolchildren in the 6-9 year age group. A cross-sectional survey was carried out in 99 schools selected by a two-stage sampling process. Children attending grades 1-4 in the selected schools were administered intradermally with 2 tuberculin units (TUs) of purified protein derivative RT23 with Tween 80, and the maximum transverse diameter of induration was measured about 72 h later. A total of 6557 children in the 6-9 year age group were satisfactorily test-read, irrespective of their bacille Calmette-Guérin (BCG) vaccination status. Based on the frequency distribution of reaction sizes obtained among satisfactorily test-read children (without and with BCG scar), the estimated ARTI rates when estimated by different methods (anti-mode, mirror-image and mixture model) varied between 1.9% and 2.5%. BCG-induced tuberculin sensitivity was not found to influence the ARTI estimates, as the differences in estimates between children without and with BCG scar were not statistically significant. TB control efforts should be further intensified to reduce the risk of tuberculous infection.

  19. Application study on aircraft structures of CFRP laminates with embedded SMA foils

    NASA Astrophysics Data System (ADS)

    Ogisu, Toshimichi; Nomura, Masato; Ando, Norio; Takaki, Junji; Takeda, Nobuo

    2002-07-01

    This paper reports some research results for the application study of the smart materials an structural using Shape Memory Alloy (SMA) foils. First, the authors acquired the recovery strain of CFRP laminates generated by the recovery stress of the pre-strained SMA foils. Then, the quasi-static load-unload tests were conducted using several kinds of quasi-isotropic CFRP laminates with embedded SMA foils. Micro-mechanics of damage behavior due to the effects of the recovery strain and the first transverse crack strain were discussed. The improvement of maximum 40 percent for the onset strain of the transverse cracks and maximum 60 percent for the onset strain of delamination were achieved for CFRP laminates with embedded pre-strained SMA foils compared with standard CFRP laminates. Furthermore, the authors conducted the structural element test for application to actual structures. Testing technique and the manufacturing technique of the structural element specimen were established.

  20. Experimental Pressure Distributions on Axisymmetric Cowls at Mach Numbers From 0.60 to 0.92

    NASA Technical Reports Server (NTRS)

    Re, Richard J.

    2006-01-01

    Pressure distributions on four nacelle cowl models of the same length and highlight area but different geometries external to the highlight are compared. The diameter ratio (ratio of highlight diameter to maximum diameter) of the four cowls was 0.854 and the length ratio (ratio of cowl length to maximum diameter) was 0.439. The cowls had the same internal geometry from the highlight to the throat with a contraction ratio (ratio of highlight area to throat area) of 1.250. Data for two other cowls which had a diameter ratio of 0.880, a length ratio of 0.400 and a contraction ratio 1.250 are also included. All the cowls had rows of static pressure orifices on the top and bottom surfaces. Mass-flow ratio was varied between 0.27 and 0.93. Some data were obtained between angles of attack from -2.1deg and 4.1deg. The test was conducted in the Langley 16-Foot Transonic Tunnel.

  1. Transverse single-mode edge-emitting lasers based on coupled waveguides.

    PubMed

    Gordeev, Nikita Yu; Payusov, Alexey S; Shernyakov, Yuri M; Mintairov, Sergey A; Kalyuzhnyy, Nikolay A; Kulagina, Marina M; Maximov, Mikhail V

    2015-05-01

    We report on the transverse single-mode emission from InGaAs/GaAs quantum well edge-emitting lasers with broadened waveguide. The lasers are based on coupled large optical cavity (CLOC) structures where high-order vertical modes of the broad active waveguide are suppressed due to their resonant tunneling into a coupled single-mode passive waveguide. The CLOC lasers have shown stable Gaussian-shaped vertical far-field profiles with a reduced divergence of ∼22° FWHM (full width at half-maximum) in CW (continuous-wave) operation.

  2. Evaluation of the relationship between the static measurement of transverse arch flexibility of the forefoot and gait parameters in healthy subjects.

    PubMed

    Kondo, Takashi; Muneta, Takeshi; Fukui, Tsutomu

    2017-03-01

    [Purpose] To investigate the relationship between the static measurement of the transverse arch of the forefoot, using a 3-dimensional (3D) foot scanner, and kinetics and kinematics of gait parameters in the sagittal plane. [Subjects and Methods] Twenty healthy subjects participated in this study. The transverse arch of the forefoot was measured under three conditions as follows: condition 1, sitting; condition 2, standing; and condition 3, foot forward and lower leg tilting anteriorly to the maximum position with heel contact. Gait parameters were recorded using a 3D motion analysis system and force plate. Correlation coefficients between TAF for each comparison of conditions and gait parameters were calculated using the Spearman correlation analysis. [Results] Rates of the transverse arch of the forefoot width and height between condition 2 and condition 3 were significantly correlated with the anterior and posterior component of ground reaction forces, the hip joint extension angle, and the ankle plantar flexion moment. [Conclusion] Our study's findings indicated that increased stiffness of the transverse arch of the forefoot was related to the increase in ankle plantar moment, and decreased stiffness of the transverse arch of the forefoot was related to the increase in hip joint extension angle during gait.

  3. Evaluation of the relationship between the static measurement of transverse arch flexibility of the forefoot and gait parameters in healthy subjects

    PubMed Central

    Kondo, Takashi; Muneta, Takeshi; Fukui, Tsutomu

    2017-01-01

    [Purpose] To investigate the relationship between the static measurement of the transverse arch of the forefoot, using a 3-dimensional (3D) foot scanner, and kinetics and kinematics of gait parameters in the sagittal plane. [Subjects and Methods] Twenty healthy subjects participated in this study. The transverse arch of the forefoot was measured under three conditions as follows: condition 1, sitting; condition 2, standing; and condition 3, foot forward and lower leg tilting anteriorly to the maximum position with heel contact. Gait parameters were recorded using a 3D motion analysis system and force plate. Correlation coefficients between TAF for each comparison of conditions and gait parameters were calculated using the Spearman correlation analysis. [Results] Rates of the transverse arch of the forefoot width and height between condition 2 and condition 3 were significantly correlated with the anterior and posterior component of ground reaction forces, the hip joint extension angle, and the ankle plantar flexion moment. [Conclusion] Our study’s findings indicated that increased stiffness of the transverse arch of the forefoot was related to the increase in ankle plantar moment, and decreased stiffness of the transverse arch of the forefoot was related to the increase in hip joint extension angle during gait. PMID:28356622

  4. Options for small-diameter hardwood utilization: past and present

    Treesearch

    Matthew S. Bumgardner; Bruce G. Hansen; Albert T. Schuler; Philip A. Araman

    2000-01-01

    Effective and maximum value use of small-diameter hardwood timber has long been of interest to forest managers and researchers. In addition to being a significant component of the standing forest base, small-diameter hardwoods often are available after thinning or other tending operations. Although the use of this material is important to achieving healthy and...

  5. Options for Small-Diameter Hardwood Utilization: Past and Present

    Treesearch

    Matthew S. Bumgardner; Bruce G. Hansen; Albert T. Schuler; Philip A. Araman; Philip A. Araman

    2001-01-01

    Effective and maximum value use of small-diameter hardwood timber has long been of interest to forest managers and researchers. In addition to being a significant component of the standing forest base, small-diameter hardwoods often are available after thinning or other tending operations. Although the use of this material is important to achieving healthy and...

  6. Analytical correlation of centrifugal compressor design geometry for maximum efficiency with specific speed

    NASA Technical Reports Server (NTRS)

    Galvas, M. R.

    1972-01-01

    Centrifugal compressor performance was examined analytically to determine optimum geometry for various applications as characterized by specific speed. Seven specific losses were calculated for various combinations of inlet tip-exit diameter ratio, inlet hub-tip diameter ratio, blade exit backsweep, and inlet-tip absolute tangential velocity for solid body prewhirl. The losses considered were inlet guide vane loss, blade loading loss, skin friction loss, recirculation loss, disk friction loss, vaneless diffuser loss, and vaned diffuser loss. Maximum total efficiencies ranged from 0.497 to 0.868 for a specific speed range of 0.257 to 1.346. Curves of rotor exit absolute flow angle, inlet tip-exit diameter ratio, inlet hub-tip diameter ratio, head coefficient and blade exit backsweep are presented over a range of specific speeds for various inducer tip speeds to permit rapid selection of optimum compressor size and shape for a variety of applications.

  7. Influence of the impact energy on the pattern of blood drip stains

    NASA Astrophysics Data System (ADS)

    Smith, F. R.; Nicloux, C.; Brutin, D.

    2018-01-01

    The maximum spreading diameter of complex fluid droplets has been extensively studied and explained by numerous physical models. This research focuses therefore on a different aspect, the bulging outer rim observed after evaporation on the final dried pattern of blood droplets. A correlation is found between the inner diameter, the maximum outer diameter, and the impact speed. This shows how the drying mechanism of a blood drip stain is influenced by the impact energy, which induces a larger spreading diameter and thus a different redistribution of red blood cells inside the droplet. An empirical relation is established between the final dried pattern of a passive bloodstain and its impact speed, yielding a possible forensic application. Indeed, being able to relate accurately the energy of the drop with its final pattern would give a clue to investigators, as currently no such simple and accurate tool exists.

  8. [3-D analysis obtained in mandible movements in children 7-15 years old with different types of occlusion].

    PubMed

    Matveev, V M; Dzaraev, Ch R; Persin, L S

    2007-01-01

    60 children with different types occlusion--normal, distal, mesial and transverse between the ages 7-15 years were selected. Using unique computer software programme and 3D digitizer MicroScribe-G2 (Company Immersion, USA) on the articulator with mounted casts, persuaded measuring the scores in different movements of mandible habitual occlusion, maximum forward movement and maximum lateral movements. Scores were calculated and results interpreted.

  9. Trajectory and Mixing Scaling Laws for Confined and Unconfined Transverse Jets

    DTIC Science & Technology

    2012-05-01

    engines , issues of confinement, very large density ratio, and super/transcritical effects complicate the utility of the ...opposite wall at a streamwise position that is one -half pipe diameter downstream of the injection location (termed moderate impaction). This...BD, and Eq. 10 scaling laws are 0.97 and 0.90, respectively. One of the primary effects of the confinement is that the

  10. Design of Mini Latissimus Dorsi Flap Based on Thoracodorsal Vascular Patterns.

    PubMed

    Elzawawy, Ehab Mostafa; Kelada, Melad Naim; Al Karmouty, Ahmed Farouk

    2018-06-01

    Latissimus dorsi (LD) flap has been used for reconstructive purposes in oncoplastic breast surgery. Using large part of the muscle as a flap leads to a residual functional loss. Muscle sparing and mini LD flaps can be used with no functional sequelae. However, the design of such flap presents a challenge. Twenty cadavers were dissected on both sides to identify the different vascular patterns of the thoracodorsal (TD) pedicle. The vessels were counted, and the following measurements were taken: diameter, length, distance from inferior angel of scapula, and vertebral level. Data were collected and entered into the personal computer. Statistical analysis was done using (SPSS/version 20) software. Five vascular patterns of TD pedicle were found. Type 1: a long vertically descending pedicle giving 3 to 4 transverse medial branches to LD in 40%. Type 2: a short pedicle terminating into 1 to 2 serratus anterior collaterals and 1 to 2 transverse lateral branches to LD in 10%. Type 3: a long vertically descending pedicle giving 2 to 3 small lateral branches to upper part of LD and terminating into medial and lateral branches in the lower part of LD in 10%. Type 4: a short pedicle that gives 4 to 5 terminal branches to LD, one of them is a long vertically descending branch to lower part of LD in 20%. Type 5: a short pedicle that terminates into a transverse medial and a long vertical branch to LD in 20%. The classically described pattern of TD pedicle (type 5) was found in 20% of cases, whereas the most commonly found pattern was type 1. This means that the pattern of TD branching is unpredictable, and a preoperative ultrasound is essential to define the existing pattern and plan the best LD flap design for each patient. In types 1 and 5, the flap can be designed using the transverse medial branch or branches. In type 2, one of the lateral transverse branches can be used. In types 3, 4, and 5, the long descending vertical branch can be used. It has a sizeable diameter (1.80.23 mm), length (12.31.64 cm), and can be located 6.50.96 cm below the inferior angle of scapula.

  11. Influence of detector pixel size, TOF resolution and DOI on image quality in MR-compatible whole-body PET.

    PubMed

    Thoen, Hendrik; Keereman, Vincent; Mollet, Pieter; Van Holen, Roel; Vandenberghe, Stefaan

    2013-09-21

    The optimization of a whole-body PET system remains a challenging task, as the imaging performance is influenced by a complex interaction of different design parameters. However, it is not always clear which parameters have the largest impact on image quality and are most eligible for optimization. To determine this, we need to be able to assess their influence on image quality. We performed Monte-Carlo simulations of a whole-body PET scanner to predict the influence on image quality of three detector parameters: the TOF resolution, the transverse pixel size and depth-of-interaction (DOI)-correction. The inner diameter of the PET scanner was 65 cm, small enough to allow physical integration into a simultaneous PET-MR system. Point sources were used to evaluate the influence of transverse pixel size and DOI-correction on spatial resolution as function of radial distance. To evaluate the influence on contrast recovery and pixel noise a cylindrical phantom of 35 cm diameter was used, representing a large patient. The phantom contained multiple hot lesions with 5 mm diameter. These lesions were placed at radial distances of 50, 100 and 150 mm from the center of the field-of-view, to be able to study the effects at different radial positions. The non-prewhitening (NPW) observer was used for objective analysis of the detectability of the hot lesions in the cylindrical phantom. Based on this analysis the NPW-SNR was used to quantify the relative improvements in image quality due to changes of the variable detector parameters. The image quality of a whole-body PET scanner can be improved significantly by reducing the transverse pixel size from 4 to 2.6 mm and improving the TOF resolution from 600 to 400 ps and further from 400 to 200 ps. Compared to pixel size, the TOF resolution has the larger potential to increase image quality for the simulated phantom. The introduction of two layer DOI-correction only leads to a modest improvement for the spheres at radial distance of 150 mm from the center of the transaxial FOV.

  12. [Analysis of normal pelvis morphometry of modern Chinese southern Han female and its correlation with age].

    PubMed

    Liu, Ping; Yu, Yan-Hong; Chen, Chun-Lin; Tang, Yi-Xin; Wang, Li; Mao, Dong-Rui; Xu, Yi-Kai; Chen, Lan

    2013-07-01

    To analyze the normal pelvis morphometry of Chinese southern Han female and its correlation with age. From August 2009 to September 2011, 289 Han nationality females who received pelvis CT scan at Nanfang Hospital of Southern Medical University were eligible for the study. Their mean age was 43.5 years, with normal body development and no pelvic abnormality. The patients were divided into 3 age groups: 25 to 40 (n = 109), 41 to 50 (n = 115), and >50 years (n = 65). After constructing a three-dimensional digital model of the pelvis, the following parameters were measured, including transverse inlet diameter, posterior sagittal diameter of pelvic inlet, sagittal inlet, diagonal conjugate, biischial diameter, posterior sagittal diameter of midpelvis, sagittal midpelvic diameter, intertuberous distance, posterior sagittal diameter of outlet, angle of pubic arch, sagittal outlet, penal height, sacrum length and sacrum curvature. The relationship between all parameters and age was analyzed. (1) The posterior sagittal diameters of pelvic inlet of the 25 to 40 age group, 41 to 50 age group, >50 years age group were (53 ± 8), (51 ± 7), (48 ± 6) mm. The sagittal inlet of the three groups were (122 ± 8), (120 ± 9), (114 ± 8) mm. And the diagonal conjugate of the three groups were (135 ± 10), (132 ± 9), (127 ± 9) mm. All had significant differences among the three groups (P < 0.01) . (2) The posterior sagittal diameter of midpelvis of the three groups were (43 ± 6), (44 ± 6), (43 ± 7) mm, and the sagittal midpelvic diameter of the three groups were (119 ± 8), (120 ± 8), (119 ± 7) mm, with no significant difference among the three groups (P > 0.05). (3) The intertuberous distance of the three groups were (122 ± 11), (121 ± 10), (117 ± 11) mm, and the posterior sagittal diameter of outlet of the three groups were (56 ± 9), (58 ± 8), (57 ± 9) mm. There was no significant difference among the three groups (P > 0.05) .(4) Penal height of three groups were (31 ± 3), (33 ± 3), (34 ± 3) mm, there was with significant differences (P < 0.01) .(5) Pearson correlation analysis showed that penal height was positively correlated with age (r = 0.331, P < 0.05), while sagittal inlet, posterior sagittal diameter of inlet, diagonal conjugate, intertuberous distance, angle of pubic arch, sacrum length and sacrum curvature were negatively correlated with age (r = -0.120 to -0.343, P < 0.05). The shape of the pelvic inlet of Chinese southern Han female changed from sagittal elliptic into transverse elliptic form, and the posterior part of pelvic inlet became larger.Sacral concavity was increased and the pelvis became deeper. Mid pelvis and the pelvic outlet was almost unchanged, and showed no correlation with age.

  13. Wave propagation in fluid-conveying viscoelastic single-walled carbon nanotubes with surface and nonlocal effects

    NASA Astrophysics Data System (ADS)

    Zhen, Ya-Xin

    2017-02-01

    In this paper, the transverse wave propagation in fluid-conveying viscoelastic single-walled carbon nanotubes is investigated based on nonlocal elasticity theory with consideration of surface effect. The governing equation is formulated utilizing nonlocal Euler-Bernoulli beam theory and Kelvin-Voigt model. Explicit wave dispersion relation is developed and wave phase velocities and frequencies are obtained. The effect of the fluid flow velocity, structural damping, surface effect, small scale effects and tube diameter on the wave propagation properties are discussed with different wave numbers. The wave frequency increases with the increase of fluid flow velocity, but decreases with the increases of tube diameter and wave number. The effect of surface elasticity and residual surface tension is more significant for small wave number and tube diameter. For larger values of wave number and nonlocal parameters, the real part of frequency ratio raises.

  14. A mechanical property and stress corrosion evaluation of 431 stainless steel alloy

    NASA Technical Reports Server (NTRS)

    Montano, J. W.

    1973-01-01

    The mechanical properties of type 431 stainless steel in two conditions: annealed bar and hardened and tempered bar are presented. Test specimens, manufactured from approximately 1.0 inch (2.54 cm) diameter bar stock, were tested at temperatures of 80 F (+26.7 C), 0 F (-17.8 C), -100 F (-73 C), and -200 F (-129 C). The test data indicated excellent tensile strength, notched/unnotched tensile ratio, ductility, shear, and impact properties at all testing temperatures. Results of the alternate immersion stress corrosion tests on stressed and unstressed longitudinal tensile specimens 0.1250 inch (0.3175 cm) diameter and transverse C-ring specimens, machined from 1.0 inch (2.54 cm) diameter bar stock, indicated that the material is not susceptible to stress corrosion cracking when tested in a 3.5 percent NaCl solution for 180 days.

  15. Double diameter boring tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ashbaugh, F.N.; Murry, K.R.

    A method of boring two concentric holes of different depths is described utilizing an elongated boring tool having a tool axis of rotation, a longitudinally disposed tool centerline axis, and first and second transverse cutting edges at one end thereof extending across the boring tool, the second cutting edge being longitudinally rearwardly recessed with respect to the first cutting edge. The method consists of inserting the boring tool into an adjustable boring head, adjusting a distance B between the tool centerline axis and the tool axis of rotation such that the tool axis of rotation intersects a first boring areamore » of the first cutting edge; and boring the concentric holes having respectively larger and smaller diameters.« less

  16. 100-mW high-power three-section tunable distributed Bragg reflector laser diodes with a real refractive-index-guided self-aligned structure

    NASA Astrophysics Data System (ADS)

    Takayama, Toru; Mochida, Atsunori; Orita, Kenji; Tamura, Satoshi; Ohnishi, Toshikazu; Yuri, Masaaki; Shimizu, Hirokazu

    2002-05-01

    High-power (>100mW) 820 nm-band distributed Bragg reflector (DBR) laser diodes (LDs) with stable fundamental transverse mode operation and continuous wavelength tuning characteristics have been developed. To obtain high-power LDs with a stable fundamental transverse mode in 820 nm wavelength range, an AlGaAs narrow stripe (2.0 micrometers ) real refractive-index-guided self-aligned (RISA) structure is utilized. In the RISA structure, the index step between inside and outside the stripe region ((Delta) n) can be precisely controlled in the order of 10-3). To maintain a stable fundamental transverse mode up to an output power over 100 mW, (Delta) n is designed to be 4x10-3. Higher-order transverse modes are effectively suppressed by a narrow stripe geometry. Further, to achieve continuous wavelength tuning capability, the three-section LD structure, which consists of the active (700micrometers ), phase control (300micrometers ), and DBR(500micrometers ) sections, is incorporated. Our DBR LDs show a maximum output power over 200mW with a stable fundamental transverse mode, and wavelength tuning characteristics ((Delta) (lambda) ~2nm) under 100 mW CW operation.

  17. A 12 coil superconducting bumpy torus magnet facility for plasma research

    NASA Technical Reports Server (NTRS)

    Roth, J. R.; Holmes, A. D.; Keller, T. A.; Krawczonek, W. M.

    1972-01-01

    A summary is presented of the performance of the two-coil superconducting pilot rig which preceded the NASA Lewis bumpy torus. This pilot rig was operated for 550 experimental runs over a period of 7 years. The NASA Lewis bumpy torus facility consists of 12 superconducting coils, each with a 19 cm in diameter and capable of producing magnetic field strengths of 3.0 teslas on their axes. The magnets are equally spaced around a major circumference 1.52 m in diameter, and are mounted with the major axis of the torus vertical in a single vacuum tank 2.59 m in diameter. The design value of maximum magnetic field on the magnetic axis (3.0 teslas) was reached and exceeded. A maximum magnetic field of 3.23 teslas was held for a period of 60 minutes, and the coils did not go to normal. When the coils were charged to a maximum magnetic field of 3.35 teslas, the coil system was driven normal without damage to the facility.

  18. Sex Determination by Biometry of Anterior Features of Human Hip Bones in South Indian Population.

    PubMed

    Rajasekhar, Sssn; Vasudha, T K; Aravindhan, K

    2017-06-01

    Sex determination is the first step in establishing the identity of skeletal remains. Many studies included biometry of posterior features of hip bone. Very few studies are reported involving the biometry of anterior features of the hip bone. Anterior features of hip bone are important especially, if there is damage to the posterior features of hip bone in cases involving deliberate disfigurement of the body to resist identification of the crime in medicolegal cases. The present study was done to evaluate the effectiveness of anterior border parameters of the hip bone for prediction of sex using discriminant function analysis in South Indian population. A total of 206 dry bones were used (121 male and 85 female) and parameters like the distance between pubic tubercle and anterior rim of acetabulum, vertical acetabular diameter, transverse acetabular diameter, and the distance between pubic tubercle to highest point on the iliopubic eminence were measured using Vernier calipers. Normally distributed variables were compared using Students t-test to analyse the significance. There was significant difference between the male and female hip bones of the observed variables with p-value less than 0.05. In parameters like the distance between pubic tubercle to anterior rim of acetabulum and distance between the highest points on iliopubic eminence to pubic tubercle; the values were more in female when compared to males. In parameters like vertical and transverse acetabular diameters; the values in males were more when compared to females. These parameters of hip bone can be utilised for sex determination in South Indian population.

  19. Biomechanical optimization of implant diameter and length for immediate loading: a nonlinear finite element analysis.

    PubMed

    Kong, Liang; Gu, Zexu; Li, Tao; Wu, Junjie; Hu, Kaijin; Liu, Yanpu; Zhou, Hongzhi; Liu, Baolin

    2009-01-01

    A nonlinear finite element method was applied to examine the effects of implant diameter and length on the maximum von Mises stresses in the jaw, and to evaluate the maximum displacement of the implant-abutment complex in immediate-loading models. The implant diameter (D) ranged from 3.0 to 5.0 mm and implant length (L) ranged from 6.0 to 16.0 mm. The results showed that the maximum von Mises stress in cortical bone was decreased by 65.8% under a buccolingual load with an increase in D. In cancellous bone, it was decreased by 71.5% under an axial load with an increase in L. The maximum displacement in the implant-abutment complex decreased by 64.8% under a buccolingual load with an increase in D. The implant was found to be more sensitive to L than to D under axial loads, while D played a more important role in enhancing its stability under buccolingual loads. When D exceeded 4.0 mm and L exceeded 11.0 mm, both minimum stress and displacement were obtained. Therefore, these dimensions were the optimal biomechanical selections for immediate-loading implants in type B/2 bone.

  20. Free-Flight Investigation of Heat Transfer to an Unswept Cylinder Subjected to an Incident Shock and Flow Interference from an Upstream Body at Mach Numbers up to 5.50

    NASA Technical Reports Server (NTRS)

    Carter, Howard S.; Carr, Robert E.

    1961-01-01

    Heat-transfer rates have been measured in free flight along the stagnation line of an unswept cylinder mounted transversely on an axial cylinder so that the shock wave from the hemispherical nose of the axial cylinder intersected the bow shock of the unswept transverse cylinder. Data were obtained at Mach numbers from 2.53 to 5.50 and at Reynolds numbers based on the transverse cylinder diameter from 1.00 x 10(exp 6) to 1.87 x 10(exp 6). Shadowgraph pictures made in a wind tunnel showed that the flow field was influenced by boundary-layer separation on the axial cylinder and by end effects on the transverse cylinder as well as by the intersecting shocks. Under these conditions, the measured heat-transfer rates had inconsistent variations both in magnitude and distribution which precluded separating the effects of these disturbances. The general magnitude of the measured heating rates at Mach numbers up to 3 was from 0.1 to 0.5 of the theoretical laminar heating rates along the stagnation line for an infinite unswept cylinder in undisturbed flow. At Mach numbers above 4 the measured heating rates were from 1.5 to 2 times the theoretical rates.

  1. All-solid tellurite optical fiber with transversely disordered refractive index profile and its optical image transport performance

    NASA Astrophysics Data System (ADS)

    Tong, Hoang Tuan; Kuroyanagi, Shunei; Suzuki, Takenobu; Ohishi, Yasutake

    2018-02-01

    All-solid tellurite-glass optical rod and fiber with transversely-disordered refractive index profile were successfully fabricated to study the transport of infrared images by using transverse localization of light. The fabrication was carried out by using stack-and-draw and rod-in-tube techniques. The fabricated tellurite optical rod and fiber were composed of high-index and low-index units which were arranged randomly in the transverse plane but were invariant in the longitudinal direction. The diameter of each unit was approximately 1.0 μm. The high-index and low-index materials were TeO2-Li2O-WO3-MoO3-Nb2O5 (TLWMN) glass and TeO2-ZnO-Na2O-La2O3 (TZNL) glass, respectively. At 1550 nm, their refractive index difference Δn is 0.096. To investigate the optical image transport capability, A CW laser light at 1550 nm was used as an input probe beam and the 1951 U.S. Air Force test target was installed in front of 10-cm-long segments of the fabricated rod and fiber in the experimental setup. The output signal was recorded by a beam profiler. As a result, clear transported images of numbers and lines on the test target were obtained.

  2. Dead wood relative to slope severity in mesic loess bluff hardwood forests

    USGS Publications Warehouse

    Twedt, Daniel J.

    2012-01-01

    To aid in identification of land within Vicksburg National Military Park that was subjected to forest restoration during the 1930s, I evaluated the hypothesized relationships between maximum live tree diameter or dead wood (standing and down) and severity of slope. Disproportionate mortality among early-successional, pioneer tree species suggested maturation of pioneer upland hardwood forests. As such, input and decomposition of dead wood have likely approached equilibrium. Thus, I did not detect a useful predictive relationship between dead wood (standing or down) or maximum diameter of live trees and severity of slope. Lack of relationships between slope and large diameter trees or volume of dead wood resulted in an inability to evaluate former land use based on these parameters.

  3. Photon Doppler velocimetry measurements of transverse surface velocities

    NASA Astrophysics Data System (ADS)

    Johnson, C. R.; LaJeunesse, J. W.; Sable, P. A.; Dawson, A.; Hatzenbihler, A.; Borg, J. P.

    2018-06-01

    The goal of this work was to develop a technique for making transverse surface velocity measures utilizing Photon Doppler Velocimetry (PDV). Such a task is achieved by transmitting light and collecting Doppler-shifted light at an angle relative to the normal axis, where measured velocities are representative of a component of the transverse velocity. Because surface characteristics have an intrinsic effect on light scatter, different surface preparations were explored to direct reflectivity, including diffusion by means of sandpapering, or increasing retroreflectivity by coating with microspheres, milling v-cuts, and electrochemically etching grooves. Testing of these surface preparations was performed using an experiment featuring a 30 mm diameter aluminum disk rotating at 6000 or 6600 RPM. A single PDV collimator was positioned along the rotational axis of the disk at various angles, resolving the apparent transverse velocity. To characterize surface preparations, light return and velocities were recorded as a function of probe angle ranging from 0° to 51° from the surface normal for each preparation. Polished and electrochemically etched surfaces did not provide enough reflected light to resolve a beat frequency; however, sandpapered surfaces, retroreflective microspheres, and milled v-cuts provided adequate reflected light for incidence angles up to 51°. Applications of the surface preparations were then studied in gas gun experiments. Retroreflective microspheres were studied in a planar impact experiment, and milled v-cuts were studied in an oblique impact experiment. A normal and transverse profile of particle velocity was resolved in the oblique impact experiment.

  4. Hair root diameter measurement as an indicator of protein deficiency in nonhospitalized alcoholics.

    PubMed

    Bregar, R R; Gordon, M; Whitney, E N

    1978-02-01

    Protein status of alcoholics admitted to a detoxification center was investigated with a view to adapting a hair root test for use in screening for protein deficiency. Hair root volume and hair root diameter had previously been shown to correlate well with hair root protein and to be sensitive indicators of protein deficiency. Hair root volumes in this study correlated well with mean maximum hair root diameters (n = 35, r = 0.9), which were simpler to measure, so diameter measurements were used. Mean maximum hair root diameters (range 0.02 to 0.19 mm) correlated with plasma RNase concentrations (range 6000 to 14,000 units/ml; n = 17, r = -0.7). Mean hair diameters of 84 alcoholics averaged 0.0864 +/- 0.0366 mm; those of 25 nonalcoholics were significantly greater: 0.100 +/- 0.0254 mm (P less than 0.05). Frequency of occurrence of hair root diameters of 0.06 mm or less was significantly higher in 71 alcoholics (29.5%) than in 23 nonalcoholics (8.6%) matched by age. Mean hair root diameters of 0.06 mm or less therefore can be used to signify protein deficiency where more expensive or technically demanding tests are not feasible. Protein deficiency occurs extensively in non hospitalized alcoholics. This method enables staff to single out those clients most likely to be in need of nutritional counseling and therapy.

  5. 49 CFR 173.417 - Authorized fissile materials packages.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... for export and import shipments. (2) A residual “heel” of enriched solid uranium hexafluoride may be... “Heel” in a Specification 7A Cylinder) Maximum cylinder diameter Centimeters Inches Cylinder volume Liters Cubic feet Maximum Uranium 235-enrichment (weight)percent Maximum “Heel” weight per cylinder UF6...

  6. 49 CFR 173.417 - Authorized fissile materials packages.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... for export and import shipments. (2) A residual “heel” of enriched solid uranium hexafluoride may be... “Heel” in a Specification 7A Cylinder) Maximum cylinder diameter Centimeters Inches Cylinder volume Liters Cubic feet Maximum Uranium 235-enrichment (weight)percent Maximum “Heel” weight per cylinder UF6...

  7. The longest wheal diameter is the optimal measurement for the evaluation of skin prick tests.

    PubMed

    Konstantinou, George N; Bousquet, Philippe-Jean; Zuberbier, Torsten; Papadopoulos, Nikolaos G

    2010-01-01

    Mean diameter or longest diameter are the 2 most frequently used parameters for wheal response assessment after skin prick testing (SPT). We aimed to compare these 2 parameters taking as gold standard the surface of the wheal skin response. Patients suspected of having an allergic reaction against inhalant allergens have been skin prick tested using the Pan-European GA(2)LEN SPT panel. Fifteen minutes later, macroscopically evident wheal and flare reactions were marked with a pen and transferred to paper with a transparent scotch tape. Each paper-transferred wheal was scanned with an ordinary scanner, and its surface-corresponding maximum perpendicular diameters and longest diameters were measured using a computer software application for image recognition, developed for this purpose. Correlation coefficients (Spearman's rho) between surfaces and respective mean (rho(mean)) or longest (rho(longest)) diameters were calculated and subsequently compared. 1,554 SPTs were performed in 74 patients. In 264, a macroscopically evident wheal and flare response was observed. Both mean and longest diameters correlated significantly with the wheal surfaces. However, rho(longest) was statistically significantly larger than rho(mean) when the surface of the wheal was >17 mm(2) (rho(longest) > 0.860 vs. rho(mean) < 0.660; p < 0.05).Such a surface corresponds to a maximum diameter of approximately 7 mm and a mean diameter of approximately 6 mm. Thus, the larger the surface of the wheal, the more appropriate the usage of the longest diameter. The longest wheal diameter alone seems to be a better surrogate marker of the wheal surface in comparison with the mean diameter. In addition, it is easier and faster to measure. Therefore, we propose this as the optimal methodology to evaluate SPTs. 2009 S. Karger AG, Basel.

  8. Triggered reverse fault and earthquake due to crustal unloading, northwest Transverse Ranges, California.

    USGS Publications Warehouse

    Yerkes, R.F.; Ellsworth, W.L.; Tinsley, J.C.

    1983-01-01

    A reverse-right-oblique surface rupture, associated with a ML 2.5 earthquake, formed in a diatomite quarry near Lompoc, California, in the northwesternmost Transverse Ranges on April 7, 1981. The 575-m-long narrow zone of ruptures formed in clay interbeds in diatomite and diatomaceous shale of the Neogene Monterey Formation. The ruptures parallel bedding, dip 39o-59oS, and trend about N84oE on the north limb of an open symmetrical syncline. Maximum net slip was 25 cm; maximum reverse dip slip was 23 cm, maximum right-lateral strike slip was about 9 cm, and average net slip was about 12 cm. The seismic moment of the earthquake is estimated at 1 to 2 X 1018 dyne/cm and the static stress drop at about 3 bar. The removal of an average of about 44 m of diatomite resulted in an average load reduction of about 5 bar, which decreased the normal stress by about 3.5 bar and increased the shear stress on the tilted bedding plane by about 2 bar. The April 7, 1981, event was a very shallow bedding-plane rupture, apparently triggered by crustal unloading. -Authors

  9. International Towing Tank Conference ITTC Symbols and Terminology List. Final Version 1996

    DTIC Science & Technology

    1997-05-13

    law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB...of water-plane aft of mWA midship 2 A AWF Area of water-plane forward mWF of midship 2 A AX Area of maximum transverse mX section 2 B B Beam or...design water line B BWL Maximum moulded breadth mWL at design water line B BX Breadth, moulded of mX maximum section area at design water line d,T T

  10. Quantitative Gross and CT measurements of Cadaveric Cervical Vertebrae (C3 – C6) as Guidelines for the Lateral mass screw fixation

    PubMed Central

    Heinneman, Thomas E.; Conti, Mathew S.; Dossous, Paul-Michel F.; Dillon, David J.; Tsiouris, Apostolos J.; Pyo, Se Young; Mtui, Estomih P.; Härtl, Roger

    2016-01-01

    Background Lateral mass screw fixation is the treatment of choice for posterior cervical stabilization. Long or misdirected screws carry a risk of injury to spinal nerve roots or vertebral artery. This study was aimed to assess the gross anatomic and CT measurements of typical cervical vertebrae for the selection of lateral mass screws. Methods Dimensions of the articular pillars were measured on 1) Dry cervical vertebrae with Vernier calipers and 2) Multiplanar reformations of CT scans of the same vertebrae with Viewer software package. The data was statistically evaluated. Results The transverse diameter of the articular pillars with Vernier calipers varied from 6.0 to 15.4 mm (mean=10.5 mm ± 1.5) and on CT scans ranged from 8.2 – 16.1 mm (mean=11.6 mm ± 1.4). The antero-posterior diameter, an estimate of the screw length by Roy-Camille technique varied from 3.9 to 12.7 mm (mean=8.6 mm ± 1.6) by Vernier calipers and from 6.4 to 13.3 mm (mean=9.1 ± 1.2) on CT scans. The oblique AP diameter, an estimate of screw length by Magerl method varied from 10.8 to 20.3 mm (mean=14.9 mm ± 1.8) by Vernier calipers and from 11.4 to 19.3 mm (mean=14.5 mm ± 1.7) on CT. The CT measurements for height, transverse and AP diameter of the articular pillars were 0.5 - 1.0 mm larger than dimensions by Vernier calipers. No statistically significant difference was observed between the caliper and CT measurements for the oblique AP diameter. Conclusion CT measurements of the articular pillars may slightly overestimate the desired screw length selected by spine surgeons when compared to actual anatomy. Although means of the articular pillars correspond to the screw lengths used, substantial number of observations below 10 mm for Roy-Camille trajectory and below 14 mm for Magerl trajectory requires careful preoperative planning and intra-operative confirmation to avoid long/misdirected lateral mass screws. PMID:28377857

  11. Determination of real-time predictors of the wind turbine wake meandering

    NASA Astrophysics Data System (ADS)

    Muller, Yann-Aël; Aubrun, Sandrine; Masson, Christian

    2015-03-01

    The present work proposes an experimental methodology to characterize the unsteady properties of a wind turbine wake, called meandering, and particularly its ability to follow the large-scale motions induced by large turbulent eddies contained in the approach flow. The measurements were made in an atmospheric boundary layer wind tunnel. The wind turbine model is based on the actuator disc concept. One part of the work has been dedicated to the development of a methodology for horizontal wake tracking by mean of a transverse hot wire rake, whose dynamic response is adequate for spectral analysis. Spectral coherence analysis shows that the horizontal position of the wake correlates well with the upstream transverse velocity, especially for wavelength larger than three times the diameter of the disc but less so for smaller scales. Therefore, it is concluded that the wake is actually a rather passive tracer of the large surrounding turbulent structures. The influence of the rotor size and downstream distance on the wake meandering is studied. The fluctuations of the lateral force and the yawing torque affecting the wind turbine model are also measured and correlated with the wake meandering. Two approach flow configurations are then tested: an undisturbed incoming flow (modelled atmospheric boundary layer) and a disturbed incoming flow, with a wind turbine model located upstream. Results showed that the meandering process is amplified by the presence of the upstream wake. It is shown that the coherence between the lateral force fluctuations and the horizontal wake position is significant up to length scales larger than twice the wind turbine model diameter. This leads to the conclusion that the lateral force is a better candidate than the upstream transverse velocity to predict in real time the meandering process, for either undisturbed (wake free) or disturbed incoming atmospheric flows.

  12. A novel missense mutation, Leu390Val, in the cardiac beta-myosin heavy chain associated with pronounced septal hypertrophy in two families with hypertrophic cardiomyopathy.

    PubMed

    Havndrup, O; Bundgaard, H; Andersen, P S; Larsen, L A; Vuust, J; Kjeldsen, K; Christiansen, M

    2000-12-01

    An examination of the genetic background and phenotypic presentation of familial hypertrophic cardiomyopathy (FHC) with respect to specific mutations in the MYH7-gene encoding the cardiac beta-myosin heavy chain. Two families (n = 22) from a cohort of 67 families with FHC were studied at the National University Hospital, Rigshospitalet, Copenhagen. Clinical, non-invasive examinations of all included family members followed by molecular genetic analysis including PCR-single strand conformation polymorphism/heteroduplex (SSCP/HD) analysis and sequencing of exon 3-23 of the MYH7-gene. We found FHC associated with a missense mutation in two families, i.e. a C > G transversion at position g10124 and a G > T transversion at position g10126 causing the change of a leucine residue at codon 390 to a valine residue. The mutation is located in the actin-binding region of the beta-myosin heavy chain. The leucine residue is evolutionarily conserved in vertebrate myosins. In the two families, the phenotypic presentations in the clinically affected were characterized by asymmetric septal hypertrophy (septum diameter 18.8 (5.0) mm (mean (SD)) with only minor involvement of the left ventricular free wall (posterior wall diameter 11.0 (2.2) mm). Furthermore, the left ventricular systolic and diastolic functions were well preserved, even at a high age. The symptomatic status of the clinically affected patients depended on the presence or absence of a concomitant left ventricular outflow tract gradient. We report a novel missense mutation associated with FHC caused by a double nucleotide transversion. The penetrance of the mutation was not complete, but in clinically affected patients the mutation gives rise to an echocardiographic phenotype, predominantly characterized by pronounced septal hypertrophy.

  13. Oriented clonal cell dynamics enables accurate growth and shaping of vertebrate cartilage.

    PubMed

    Kaucka, Marketa; Zikmund, Tomas; Tesarova, Marketa; Gyllborg, Daniel; Hellander, Andreas; Jaros, Josef; Kaiser, Jozef; Petersen, Julian; Szarowska, Bara; Newton, Phillip T; Dyachuk, Vyacheslav; Li, Lei; Qian, Hong; Johansson, Anne-Sofie; Mishina, Yuji; Currie, Joshua D; Tanaka, Elly M; Erickson, Alek; Dudley, Andrew; Brismar, Hjalmar; Southam, Paul; Coen, Enrico; Chen, Min; Weinstein, Lee S; Hampl, Ales; Arenas, Ernest; Chagin, Andrei S; Fried, Kaj; Adameyko, Igor

    2017-04-17

    Cartilaginous structures are at the core of embryo growth and shaping before the bone forms. Here we report a novel principle of vertebrate cartilage growth that is based on introducing transversally-oriented clones into pre-existing cartilage. This mechanism of growth uncouples the lateral expansion of curved cartilaginous sheets from the control of cartilage thickness, a process which might be the evolutionary mechanism underlying adaptations of facial shape. In rod-shaped cartilage structures (Meckel, ribs and skeletal elements in developing limbs), the transverse integration of clonal columns determines the well-defined diameter and resulting rod-like morphology. We were able to alter cartilage shape by experimentally manipulating clonal geometries. Using in silico modeling, we discovered that anisotropic proliferation might explain cartilage bending and groove formation at the macro-scale.

  14. Periodontal evaluation in patients undergoing maxillary expansion.

    PubMed

    Carmen, M; Marcella, P; Giuseppe, C; Roberto, A

    2000-09-01

    Maxillary transverse diameter expansion is a treatment various authors have claimed is related to the development of gingival recession on the teeth of the upper arch. The aim of the present study was to compare such an incidence in two different groups of patients: those treated with surgically assisted rapid maxillary expansion and orthopedic expansion, respectively. Both treatments achieved the goal of expanding the transverse dimension (5.3 and 4.4 mm, respectively), but a significant difference was shown by the chi 2 test for the incidence of gingival recession of premolar/molar upper teeth, more than double for the latter than for the former. Therefore, surgically assisted rapid maxillary expansion seems to be an orthodontically effective procedure, safer than the orthopedic treatment regarding the possible development of mucogingival problems.

  15. A minimax technique for time-domain design of preset digital equalizers using linear programming

    NASA Technical Reports Server (NTRS)

    Vaughn, G. L.; Houts, R. C.

    1975-01-01

    A linear programming technique is presented for the design of a preset finite-impulse response (FIR) digital filter to equalize the intersymbol interference (ISI) present in a baseband channel with known impulse response. A minimax technique is used which minimizes the maximum absolute error between the actual received waveform and a specified raised-cosine waveform. Transversal and frequency-sampling FIR digital filters are compared as to the accuracy of the approximation, the resultant ISI and the transmitted energy required. The transversal designs typically have slightly better waveform accuracy for a given distortion; however, the frequency-sampling equalizer uses fewer multipliers and requires less transmitted energy. A restricted transversal design is shown to use the least number of multipliers at the cost of a significant increase in energy and loss of waveform accuracy at the receiver.

  16. Suppressing wall turbulence by means of a transverse traveling wave

    PubMed

    Du; Karniadakis

    2000-05-19

    Direct numerical simulations of wall-bounded flow reveal that turbulence production can be suppressed by a transverse traveling wave. Flow visualizations show that the near-wall streaks are eliminated, in contrast to other turbulence-control techniques, leading to a large shear stress reduction. The traveling wave can be induced by a spanwise force that is confined within the viscous sublayer; it has its maximum at the wall and decays exponentially away from it. We demonstrate the application of this approach in salt water, using arrays of electromagnetic tiles that produce the required traveling wave excitation at a high efficiency.

  17. Influence of shoulder diameter on Temperature and Z-parameter during friction stir welding of Al 6082 alloy

    NASA Astrophysics Data System (ADS)

    Kishore Mugada, Krishna; Adepu, Kumar

    2018-03-01

    In this research article, the effect of increasing shoulder diameter on temperature and Zener Holloman (Z)-parameter for friction stir butt welded AA6082-T6 was studied. The temperature at the Advancing side (AS) of weld was measured using the K-Type thermocouple at four different equidistant locations. The developed analytical model is utilized to predict the maximum temperature (Tpeak) during the welding. The strain, strain rate, Z- Parameter for all the shoulders at four distinct locations were evaluated. The temperature increases with increase in shoulder diameter and the maximum temperature was recorded for 24mm shoulder diameter. The computed log Z values are compared with the available process map and results shows that the values are in stable flow region and near to stir zone the values are in Dynamic recrystallization region (DRX). The axial load (Fz) and total tool torque (N-m) are found to be higher for shoulder diameter of 21 mm i.e., 6.3 kN and 56.5 N-m respectively.

  18. Analysis of wind-resistant and stability for cable tower in cable-stayed bridge with four towers

    NASA Astrophysics Data System (ADS)

    Meng, Yangjun; Li, Can

    2017-06-01

    Wind speed time history simulation methods have been introduced first, especially the harmonic synthesis method introduced in detail. Second, taking Chishi bridge for example, choosing the particular sections, and combined with the design wind speed, three-component coefficient simulate analysis between -4°and 4°has been carry out with the Fluent software. The results show that drag coefficient reaches maximum when the attack Angle is 1°. According to measured wind speed samples,time history curves of wind speed at bridge deck and tower roof have been obtained,and wind-resistant time history analysis for No.5 tower has been carry out. Their results show that the dynamic coefficients are different with different calculation standard, especially transverse bending moment, pulsating crosswind load does not show a dynamic amplification effect.Under pulsating wind loads at bridge deck or tower roof, the maximum displacement at the top of the tower and the maximum stress at the bottom of the tower are within the allowable range. The transverse stiffness of tower is greater than that of the longitudinal stiffness, therefore wind-resistant analysis should give priority to the longitudinal direction. Dynamic coefficients are different with different standard, the maximum dynamic coefficient should be used for the pseudo-static analysis.Finally, the static stability of tower is analyzed with different load combinations, and the galloping stabilities of cable tower is proved.

  19. Change in Abdominal Morphology After Surgical Correction of Thoracolumbar Kyphosis Secondary to Ankylosing Spondylitis: A Computed Tomographic Study.

    PubMed

    Ji, Ming-Liang; Qian, Bang-Ping; Qiu, Yong; Wang, Bin; Mao, Sai-Hu; Zhu, Ze-Zhang; Yu, Yang

    2015-12-01

    A computed tomographic study. To investigate the change in abdominal morphology in surgically treated patients with ankylosing spondylitis (AS) and thoracolumbar kyphosis. Severe thoracolumbar kyphosis in patients with AS exerts pressure on the abdominal cavity and subsequently causes intra-abdominal complications. Several spinal osteotomy techniques have been widely used to correct AS-related thoracolumbar kyphosis. To date, the changed abdominal morphology in patients with AS undergoing surgical correction of thoracolumbar kyphosis has not been addressed. A total of 29 patients with AS undergoing lumbar pedicle subtraction osteotomy for correction of thoracolumbar kyphosis were retrospectively reviewed. Computed tomographic scans of the spine were used to measure the longitudinal, transverse, and anterior-posterior diameters of the abdominal cavity. Furthermore, the abdominal cavity was considered as an ellipsoid structure, thereby allowing calculation of its volume. Radiographical evaluations included global kyphosis (GK), thoracic kyphosis, lumbar lordosis (LL), and angle of fusion levels (AFL). The longitudinal diameter of abdominal cavity significantly increased (P < 0.01), whereas the transverse and anterior-posterior diameters of the abdominal cavity did not change, postoperatively (P > 0.05). Significant changes in GK, LL, and AFL were observed (P < 0.01). The abdominal cavity volume (ACV) increased by an average of 652  mL. The change in ACV was significantly correlated with the changes in GK (r = 0.453, P = 0.014), LL (r = 0.42, P = 0.023), and AFL (r = 0.388, P = 0.037). The increased ACV after correction of thoracolumbar kyphosis was quantitatively confirmed by this study. Thus, the improvement in digestive function after correction of thoracolumbar kyphosis secondary to AS, which has been previously documented, may be because of an increase in ACV. Moreover, spine surgeons should be aware of the potential risk for the development of abdominal complications caused by the lengthening of longitudinal diameter of the abdominal cavity. 3.

  20. First principles study of size and external electric field effects on the atomic and electronic properties of gallium nitride nanostructures

    NASA Astrophysics Data System (ADS)

    Yilmaz, Hulusi

    A comprehensive density functional theory study of atomic and the electronic properties of wurtzite gallium nitride (GaN) nanostructures with different sizes and shapes is presented and the effect of external electric field on these properties is examined. We show that the atomic and electronic properties of [101¯0] facet single-crystal GaN nanotubes (quasi-1D), nanowires (1D) and nanolayers (2D) are mainly determined by the surface to volume ratio. The shape dependent quantum confinement and strain effects on the atomic and electronic properties of these GaN nanostructures are found to be negligible. Based on this similarity between the atomic and electronic properties of the small size GaN nanostructures, we calculated the atomic and electronic properties of the practical size (28.1 A wall thickness) single-crystal GaN nanotubes through computational much economical GaN nanoslabs (nanolayers). Our results show that, regardless of diameter, hydrogen saturated single-crystal GaN tubes with the wall thickness of 28.1 A are energetically stable and they have a noticeably larger band gap with respect to the band gap of bulk GaN. The band gap of unsaturated single-crystal GaN tubes, on the other hand, is always smaller than the band gap of the wurtzite bulk GaN. In a separate study, we show that a transverse electric field induces a homojunction across the diameter of initially semiconducting GaN single-crystal nanotubes and nanowires. The homojunction arises due to the decreased energy of the electronic states in the higher potential region with respect to the energy of those states in the lower potential region under the transverse electric field. Calculations on single-crystal GaN nanotubes and nanowires of different diameter and wall thickness show that the threshold electric field required for the semiconductor-homojunction induction increases with increasing wall thickness and decreases significantly with increasing diameter.

  1. The impact of clinical use on the torsional behavior of Reciproc and WaveOne instruments.

    PubMed

    Magalhães, Rafael Rodrigues Soares de; Braga, Lígia Carolina Moreira; Pereira, Érika Sales Joviano; Peixoto, Isabella Faria da Cunha; Buono, Vicente Tadeu Lopes; Bahia, Maria Guiomar de Azevedo

    2016-01-01

    The aim of this study was to assess the influence of clinical use, in vivo, on the torsional behavior of Reciproc and WaveOne instruments considering the possibility that they degraded with use. Diameter at each millimeter, pitch length, and area at 3 mm from the tip were determined for both types of instruments. Twenty-four instruments, size 25, 0.08 taper, of each system were divided into two groups (n=12 each): Control Group (CG), in which new Reciproc (RC) and WaveOne Primary (WO) instruments were tested in torsion until rupture based on ISO 3630-1; and Experimental Group (EG), in which each new instrument was clinically used to clean and shape the root canals of one molar. After clinical use, the instruments were analyzed using optical and scanning electron microscopy and subsequently tested in torsion until fracture. Data were analyzed using one-way analysis of variance at a=.05. WO instruments showed significantly higher mean values of cross-sectional area A3 (P=0.000) and smaller pitch lengths than RC instruments with no statistically significant differences in the diameter at D3 (P=0.521). No significant differences in torsional resistance between the RC and WO new instruments (P=0.134) were found. The clinical use resulted in a tendency of reduction in the maximum torque of the analyzed instruments but no statistically significant difference was observed between them (P=0.327). During the preparation of the root canals, two fractured RC instruments and longitudinal and transversal cracks in RC and WO instruments were observed through SEM analysis. After clinical use, no statistically significant reduction in the torsional resistance was observed.

  2. Tunable Microwave Transversal Filters.

    DTIC Science & Technology

    1984-05-01

    magnetostatic waves MSW propagating at microwave frequency in magnetically biased, liquid phase epitaxial films of yttrium iron garnet (YIG) grown on...25 uM-thick 3 mm-wide and 15 mm-long YIG film grown by liquid phase epitaxy On a 500 uM-thick ( ) gadolinium gallium garnet (GGG) substrate was used...obtained. The delay line material was prepared by growing YIG films on one inch diameter gallium gadolinium garnet (GGG) wafers using the liquid

  3. Maxillary tridimensional changes after slow expansion with leaf expander in a sample of growing patients: a pilot study.

    PubMed

    Lanteri, V; Gianolio, A; Gualandi, G; Beretta, M

    2018-03-01

    The aim of this study is to evaluate the dento-alveolar effects of slow maxillary expansion using the Leaf Expander in a sample of growing patients with maxillary transverse deficiency, unilateral cross bite and mandibular shift. The study included 10 patients, 3 male and 7 female (mean age 7.5 + 7 months), treated with Leaf Expander anchored on the upper deciduous teeth. Digital models were obtained by a lab scan of the pvs impressions at the beginning of the therapy (T1) and at the removal of the palatal expander (T2). Five parameters were measured: 1) the distance between the first upper permanent molars; 2) the distance between the upper second deciduous molars; 3) the distance between the upper canine cusps 4) the distance between the first lower permanent molars; 5) the distance of the lower canine cusps. In all patients complete correction of posterior crossbite was achieved on average in 4 months, with a spontaneous expansion of the upper first permanent molars. Significant increases in the dento-alveolar transversal diameters were obtained. Increases were also observed in the anterior mandibular arch diameter (+ 1 mm). These findings suggest that slow maxillary expansion using Leaf Expander appliance could be a reasonable alternative to conventional maxillary expansion therapy in the early mixed dentition.

  4. An AC modulated near infrared gain calibration system for a “Violin-Mode” transimpedance amplifier, intended for advanced LIGO suspensions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lockerbie, N. A.; Tokmakov, K. V.

    The background to this work was a prototype shadow sensor, which was designed for retro-fitting to an advanced LIGO (Laser Interferometer Gravitational wave Observatory) test-mass/mirror suspension, in which a 40 kg test-mass/mirror is suspended by four approximately 600 mm long by 0.4 mm diameter fused-silica suspension fibres. The shadow sensor comprised a LED source of Near InfraRed (NIR) radiation, and a “tall-thin” rectangular silicon photodiode detector, which together were to bracket the fibre under test. The photodiode was positioned so as to be sensitive (primarily) to transverse “Violin-Mode” vibrations of such a fibre, via the oscillatory movement of the shadowmore » cast by the fibre, as this moved across the face of the detector. In this prototype shadow sensing system the photodiode was interfaced to a purpose-built transimpedance amplifier, this having both AC and DC outputs. A quasi-static calibration was made of the sensor’s DC responsivity, i.e., incremental rate of change of output voltage versus fibre position, by slowly scanning a fused-silica fibre sample transversely through the illuminating beam. The work reported here concerns the determination of the sensor’s more important AC (Violin-Mode) responsivity. Recognition of the correspondence between direct AC modulation of the source, and actual Violin-Mode signals, and of the transformative role of the AC/DC gain ratio for the amplifier, at any modulation frequency, f, resulted in the construction of the AC/DC calibration source described here. A method for determining in practice the transimpedance AC/DC gain ratio of the photodiode and amplifier, using this source, is illustrated by a specific numerical example, and the gain ratio for the prototype sensing system is reported over the frequency range 1 Hz–300 kHz. In fact, a maximum DC responsivity of 1.26 kV.m{sup −1} was measured using the prototype photodiode sensor and amplifier discussed here. Therefore, the measured AC/DC transimpedance gain ratio of 922.5 for this sensor, at 500 Hz, translated into a maximum Violin-Mode (AC) responsivity of (1.16 ± 0.05) MV m{sup −1}, at that frequency.« less

  5. Echocolor Doppler morpho-functional study of the jugulo-subclavian confluence in chronic cerebro-spinal venous insufficiency and multiple sclerosis patients.

    PubMed

    Mandolesi, Sandro; d'Alessandro, Aldo; Desogus, Antonello Ignazio; Ciccone, Marco Matteo; Zito, Annapaola; Stammegna, Immacolata; Niglio, Tarcisio; Orsini, Augusto; Mandolesi, Dimitri; d'Alessandro, Alessandro; Revelli, Luca

    2017-01-01

    The aim of this work is to measure the mean diameter of the confluence jugulo- subclavian, the impact of different types of jugular confluences and the correlation between the types of confluences and the Valsalva maneuver (jugular reflux) in subjects with Chronic Cerebro-Spinal Venous Insufficiency (CCSVI) and Multiple Sclerosis. We investigated by Echo-Color-Doppler (ECD) 103 subjects (67 F 36M) of mean age 45 ± 12 years (a minimum of 22 to a maximum of 79 years, with a median of 44 and a modal value 42 years), mean EDSS of 4.7 and average disease duration of 12 years. The 103 right jugular veins investigated had an average diameter of 8.4 ± 2.4 mm (minimum 4.0, maximum 14.9 mm; median 7.9; modal value 7.6 mm). Three form types were found: 56 cylindrical, 29 conical and 18 funnel. Valsalva maneuver was positive in 30 patients. The 103 left jugular investigated had an average diameter of 8.9 ± 2.4 mm (minimum 2.8, maximum 14.4 mm; median of 8.8; modal value 8.7 mm). The form types were found: 42 cylindrical, 45 conical and 16 funnel. Valsalva maneuver was positive in 30 patients. The mean diameter of the jugular veins was 8.7 mm. Internal jugular veins with cylindrical morphology have a diameter smaller than other forms; this difference is statistically significant. The different morphology of the jugular vein confluence does not increase the possibility of a reflux because the positive Valsalva maneuvers are not statistically significant when compared to the various types. CCSVI, EchoColorDoppler Map, Jugulo-Subclavian Confluence Diameter.

  6. Stocking and structure for maximum growth in sugar maple selection stands.

    Treesearch

    Thomas R. Crow; Carl H. Tubbs; Rodney D. Jacobs; Robert R. Oberg

    1981-01-01

    The impacts of stocking, structure, and cutting cycle on basal area, cubic foot volume, board foot volume, and diameter growth are considered. Recommendations are provided for maximum growth in uneven-aged sugar maple stands.

  7. Oxidation at through-hole defects in fused slurry silicide coated columbium alloys FS-85 and Cb-752

    NASA Technical Reports Server (NTRS)

    Levine, S. R.

    1973-01-01

    Metal recession and interstitial contamination at 0.08-centimeter-diameter through-hole intentional defects in fused slurry silicide coated FS-85 and Cb-752 columbium alloys were studied to determine the tolerance of these materials to coating defects. Five external pressure reentry simulation exposures to 1320 C and 4.7 x 1,000 N/sq m (maximum pressure) resulted in a consumed metal zone having about twice the initial defect diameter for both alloys with an interstitial contamination zone extending about three to four initial defect diameters. Self-healing occurred in the 1.33 x 10 N/sq m, 1320 C exposures and to a lesser extent in internal pressure reentry cycles to 1320 C and 1.33 x 100 N/sq m (maximum pressure).

  8. Bifurcation scenarios for bubbling transition.

    PubMed

    Zimin, Aleksey V; Hunt, Brian R; Ott, Edward

    2003-01-01

    Dynamical systems with chaos on an invariant submanifold can exhibit a type of behavior called bubbling, whereby a small random or fixed perturbation to the system induces intermittent bursting. The bifurcation to bubbling occurs when a periodic orbit embedded in the chaotic attractor in the invariant manifold becomes unstable to perturbations transverse to the invariant manifold. Generically the periodic orbit can become transversely unstable through a pitchfork, transcritical, period-doubling, or Hopf bifurcation. In this paper a unified treatment of the four types of bubbling bifurcation is presented. Conditions are obtained determining whether the transition to bubbling is soft or hard; that is, whether the maximum burst amplitude varies continuously or discontinuously with variation of the parameter through its critical value. For soft bubbling transitions, the scaling of the maximum burst amplitude with the parameter is derived. For both hard and soft transitions the scaling of the average interburst time with the bifurcation parameter is deduced. Both random (noise) and fixed (mismatch) perturbations are considered. Results of numerical experiments testing our theoretical predictions are presented.

  9. Micromagnetic evaluation of the dissipated heat in cylindrical magnetic nanowires

    NASA Astrophysics Data System (ADS)

    Fernandez-Roldan, Jose Angel; Serantes, David; del Real, Rafael P.; Vazquez, Manuel; Chubykalo-Fesenko, Oksana

    2018-05-01

    Magnetic nanowires (NWs) are promising candidates for heat generation under AC-field application due to their large shape anisotropy. They may be used for catalysis, hyperthermia, or water purification treatments. In the present work, we theoretically evaluate the heat dissipated by a single magnetic nanowire, originated from the domain wall (DW) dynamics under the action of an AC-field. We compare the Permalloy NWs (which demagnetize via the transverse wall propagation) with the Co fcc NWs whose reversal mode is via a vortex domain wall. The average hysteresis loop areas—which are proportional to the Specific Absorption Rate (SAR)—as a function of the field frequency have a pronounced maximum in the range 200 MHz-1 GHz. This maximum frequency is smaller in Permalloy than that in Co and depends on the nanowire length. A simple model related to the nucleation and propagation time and DW velocity (higher for the vortex than for the transverse domain wall) is proposed to explain the non-monotonic SAR dependence on the frequency.

  10. Single mode, broad-waveguide ARROW-type semiconductor diode lasers

    NASA Astrophysics Data System (ADS)

    Al-Muhanna, Abdulrahman Ali

    A broad transverse waveguide (low confinement) concept is used to achieve a record-high spatially incoherent cw output power of 11W for InGaAs active devices (λ = 0.97 μm) from 100μm wide-stripe and 2mm-long devices with low internal loss, α1 = 1cm-1, and high characteristic temperatures, T0 = 210K, and T1 = 1800K. A detailed above-threshold analysis reveals that reduction in gain spatial hole burning (GSHB) is possible in ARROW-type structures by using a low transverse confinement factor; consequently, a wider ARROW-core can be utilized. By incorporating both a broad-waveguide concept as well as an asymmetric structure in the transverse direction, and an ARROW-type structure in the lateral direction, a novel single-spatial mode diode laser with improved performance is obtained. Devices with low transverse confinement factor (Γ ~ 1%) and a core-region width of 7.8 μm achieved 510mW single-spatial mode pulsed output power (λ = 0.946 μm) with a full- width at half-maximum (FWHM) of the lateral far-field pattern of 4.7°.

  11. Applications of a new mass-driver concept

    NASA Technical Reports Server (NTRS)

    Oneill, G. K.

    1981-01-01

    A description of the operating principles and requirements of a novel mass-driver concept is presented. The design obtains acceleration of payload bucket coils by means of transverse focussing from strong, off-axis restoring forces that are produced by drive coils operating in a 'pull-only' mode. The concept offers the unprecedented possibility of operating high-performance mass-drivers entirely within the limitations of existing commercial switching devices, such as silicon-controlled rectifiers, spark gaps, vacuum-triggered arcs or vacuum mechanical switches. Representative applications of the concept described are: (1) a large-diameter magnetic lunar launcher for payloads having autonomous maneuvering; (2) an intermediate-diameter launcher with long operational life; and (3) a reaction engine for orbit transfer of large, massive objects.

  12. Analysis of eddy currents induced by transverse and longitudinal gradient coils in different tungsten collimators geometries for SPECT/MRI integration.

    PubMed

    Samoudi, Amine M; Van Audenhaege, Karen; Vermeeren, Günter; Poole, Michael; Tanghe, Emmeric; Martens, Luc; Van Holen, Roel; Joseph, Wout

    2015-12-01

    We investigated the temporal variation of the induced magnetic field due to the transverse and the longitudinal gradient coils in tungsten collimators arranged in hexagonal and pentagonal geometries with and without gaps between the collimators. We modeled x-, y-, and z-gradient coils and different arrangements of single-photon emission computed tomography (SPECT) collimators using FEKO, a three-dimensional electromagnetic simulation tool. A time analysis approach was used to generate the pulsed magnetic field gradient. The approach was validated with measurements using a 7T MRI scanner. Simulations showed an induced magnetic field representing 4.66% and 0.87% of the applied gradient field (gradient strength = 500 mT/m) for longitudinal and transverse gradient coils, respectively. These values can be reduced by 75% by adding gaps between the collimators for the pentagonal arrangement, bringing the maximum induced magnetic field to less than 2% of the applied gradient for all of the gradient coils. Characterization of the maximum induced magnetic field shows that by adding gaps between the collimators for an integrated SPECT/MRI system, eddy currents can be corrected by the MRI system to avoid artifact. The numerical model was validated and was proposed as a tool for studying the effect of a SPECT collimator within the MRI gradient coils. © 2014 Wiley Periodicals, Inc.

  13. Characteristics of the turbulence in the flow at a tidal stream power site.

    PubMed

    Milne, I A; Sharma, R N; Flay, R G J; Bickerton, S

    2013-02-28

    This paper analyses a set of velocity time histories which were obtained at a fixed point in the bottom boundary layer of a tidal stream, 5 m from the seabed, and where the mean flow reached 2.5 m s(-1). Considering two complete tidal cycles near spring tide, the streamwise turbulence intensity during non-slack flow was found to be approximately 12-13%, varying slightly between flood and ebb tides. The ratio of the streamwise turbulence intensity to that of the transverse and vertical intensities is typically 1 : 0.75 : 0.56, respectively. Velocity autospectra computed near maximum flood tidal flow conditions exhibit an f(-2/3) inertial subrange and conform reasonably well to atmospheric turbulence spectral models. Local isotropy is observed between the streamwise and transverse spectra at reduced frequencies of f>0.5. The streamwise integral time scales and length scales of turbulence at maximum flow are approximately 6 s and 11-14 m, respectively, and exhibit a relatively large degree of scatter. They are also typically much greater in magnitude than the transverse and vertical components. The findings are intended to increase the levels of confidence within the tidal energy industry of the characteristics of the higher frequency components of the onset flow, and subsequently lead to more realistic performance and loading predictions.

  14. Digital terrestrial photogrammetric methods for tree stem analysis

    Treesearch

    Neil A. Clark; Randolph H. Wynne; Daniel L. Schmoldt; Matt Winn

    2000-01-01

    A digital camera was used to measure diameters at various heights along the stem on 20 red oak trees. Diameter at breast height ranged from 16 to over 60 cm, and height to a 10-cm top ranged from 12 to 20 m. The chi-square maximum anticipated error of geometric mean diameter estimates at the 95 percent confidence level was within ±4 cm for all heights when...

  15. Nonlinear theory of transverse beam echoes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sen, Tanaji; Li, Yuan Shen

    Transverse beam echoes can be excited with a single dipole kick followed by a single quadrupole kick. They have been used to measure diffusion in hadron beams and have other diagnostic capabilities. Here we develop theories of the transverse echo nonlinear in both the dipole and quadrupole kick strengths. The theories predict the maximum echo amplitudes and the optimum strength parameters. We find that the echo amplitude increases with smaller beam emittance and the asymptotic echo amplitude can exceed half the initial dipole kick amplitude. We show that multiple echoes can be observed provided the dipole kick is large enough.more » The spectrum of the echo pulse can be used to determine the nonlinear detuning parameter with small amplitude dipole kicks. Simulations are performed to check the theoretical predictions. In the useful ranges of dipole and quadrupole strengths, they are shown to be in reasonable agreement.« less

  16. Nonlinear theory of transverse beam echoes

    DOE PAGES

    Sen, Tanaji; Li, Yuan Shen

    2018-02-23

    Transverse beam echoes can be excited with a single dipole kick followed by a single quadrupole kick. They have been used to measure diffusion in hadron beams and have other diagnostic capabilities. Here we develop theories of the transverse echo nonlinear in both the dipole and quadrupole kick strengths. The theories predict the maximum echo amplitudes and the optimum strength parameters. We find that the echo amplitude increases with smaller beam emittance and the asymptotic echo amplitude can exceed half the initial dipole kick amplitude. We show that multiple echoes can be observed provided the dipole kick is large enough.more » The spectrum of the echo pulse can be used to determine the nonlinear detuning parameter with small amplitude dipole kicks. Simulations are performed to check the theoretical predictions. In the useful ranges of dipole and quadrupole strengths, they are shown to be in reasonable agreement.« less

  17. Scaling Effects in Carbon/Epoxy Laminates Under Transverse Quasi-Static Loading

    NASA Technical Reports Server (NTRS)

    Nettles, Alan T.; Douglas, Michael J.; Estes, Eric E.

    1999-01-01

    Scaling effects were considered for 8, 16, 32, and 64 ply IM-7/8551-7 carbon/epoxy composites plates transversely loaded to the first significant load drop by means of both a quasi-static and an equivalent impact force. The resulting damage was examined by x-ray and photomicroscopy analysis. Load-deflection curves were generated for the quasi-static tests and the resulting indentation depth was measured. Results showed that the load-deflection data scaled well for most of the various thicknesses of plates. However, damage did not scale as well. No correlation could be found between dent depth and any of the other parameters measured in this study. The impact test results showed that significantly less damage was formed compared to the quasi- static results for a given maximum transverse load. The criticality of ply-level scaling (grouping plies) was also examined.

  18. Estimation of the Mean Axon Diameter and Intra-axonal Space Volume Fraction of the Human Corpus Callosum: Diffusion q-space Imaging with Low q-values.

    PubMed

    Suzuki, Yuriko; Hori, Masaaki; Kamiya, Kouhei; Fukunaga, Issei; Aoki, Shigeki; VAN Cauteren, Marc

    2016-01-01

    Q-space imaging (QSI) is a diffusion-weighted imaging (DWI) technique that enables investigation of tissue microstructure. However, for sufficient displacement resolution to measure the microstructure, QSI requires high q-values that are usually difficult to achieve with a clinical scanner. The recently introduced "low q-value method" fits the echo attenuation to only low q-values to extract the root mean square displacement. We investigated the clinical feasibility of the low q-value method for estimating the microstructure of the human corpus callosum using a 3.0-tesla clinical scanner within a clinically feasible scan time. We performed a simulation to explore the acceptable range of maximum q-values for the low q-value method. We simulated echo attenuations caused by restricted diffusion in the intra-axonal space (IAS) and hindered diffusion in the extra-axonal space (EAS) assuming 100,000 cylinders with various diameters, and we estimated mean axon diameter, IAS volume fraction, and EAS diffusivity by fitting echo attenuations with different maximum q-values. Furthermore, we scanned the corpus callosum of 7 healthy volunteers and estimated the mean axon diameter and IAS volume fraction. Good agreement between estimated and defined values in the simulation study with maximum q-values of 700 and 800 cm(-1) suggested that the maximum q-value used in the in vivo experiment, 737 cm(-1), was reasonable. In the in vivo experiment, the mean axon diameter was larger in the body of the corpus callosum and smaller in the genu and splenium, and this anterior-to-posterior trend is consistent with previously reported histology, although our mean axon diameter seems larger in size. On the other hand, we found an opposite anterior-to-posterior trend, with high IAS volume fraction in the genu and splenium and a lower fraction in the body, which is similar to the fiber density reported in the histology study. The low q-value method may provide insights into tissue microstructure using a 3T clinical scanner within clinically feasible scan time.

  19. Comparative Analysis of the Mini-pterional and Supraorbital Keyhole Craniotomies for Unruptured Aneurysms with Numeric Measurements of Their Geometric Configurations.

    PubMed

    Kang, Ho-Jun; Lee, Yoon-Soo; Suh, Sang-Jun; Lee, Jeong-Ho; Ryu, Kee-Young; Kang, Dong-Gee

    2013-03-01

    Keyhole craniotomy is a modification of pterional craniotomy that allows for use of a minimally invasive approach toward cerebral aneurysms. Currently, mini-pterional (MPKC) and supraorbital keyhole craniotomies (SOKC) are commonly used. In this study, we measured and compared the geometric configurations of surgical exposure provided by MPKC and SOKC. Nine patients underwent MPKC and four underwent SOKC. Their postoperative contrast-enhanced brain computed tomographic scans were evaluated. The transverse and longitudinal diameters and areas of exposure were measured. The locations of the anterior communicating artery, bifurcation of the middle cerebral artery (MCAB), and the internal carotid artery (ICA) terminal were identified, and the working angles and depths for these targets were measured. No significant differences in the transverse diameters of exposure were observed between MPKC and SOKC. However, the longitudinal diameters and the areas were significantly larger, by 1.5 times in MPKC. MPKC provided larger operable working angles for the targets. The angles by MPKC, particularly for the MCAB, reached up to 1.9-fold of those by SOKC. Greater working depths were required in order to reach the targets by SOKC, and the differences were the greatest in the MCAB by 1.6-fold. MPKC provides larger exposure than SOKC with a similar length of skin incision. MPKC allows for use of a direct transsylvian approach, and exposes the target in a wide working angle within a short distance. Despite some limitations in exposure, SOKC is suitable for a direct subfrontal approach, and provides a more anteromedial and basal view. MCAB and posteriorly directing ICA terminal aneurysms can be good candidates for MPKC.

  20. A morphological and morphometric study of proximal and distal ends of dry radii with its clinical implications.

    PubMed

    Gupta, Chandni; Kalthur, Sneha Guruprasad; Malsawmzuali, J C; D'souza, Antony Sylvan

    2015-01-01

    Knowledge of the size and shape of radial head is essential for construction of radial head prosthesis. Further, the measurements of bicipital tuberosity and its angular relationship to radial head are significant in surgical techniques, like in the reconstruction of biceps tendon. Even the morphometry of the distal radius is significant in numerous clinical orthopedic situations such as reduction of distal radius fractures and in the design of distal radius prosthesis. So, the aim of the study was to determine the morphometric parameters of proximal and distal radius in dry adult Indian radius. Fifty intact adult Indian radius (right = 23, left = 27) were chosen, and the various parameters of proximal and distal ends of radius were studied. Student's t-test was done to correlate all these parameters on the right and left sides. The mean length of radius, height of head at medial and lateral ends, head anteroposterior and transverse diameter, head thickness at ventral, dorsal, and lateral ends were 23.5, 0.90, 0.75, 1.91, 1.85, 0.42, 0.32, and 0.30 cm, respectively. The mean depth of articular facet, length of neck, proximal and distal neck diameter, width and length of bicipital tuberosity, and radial circumference at bicipital tuberosity were 0.19, 1.19, 1.36, 1.31, 1.23, 1.97, and 4.54 cm, respectively. The mean length of styloid process, oblique and transverse width of lower end, anteroposterior diameter of lower end, and angle of radial inclination were 0.98cm, 2. 81cm, 2.59cm, 1.86cm, and 25.05°, respectively. This study will be useful for orthopedic surgeons in making prosthesis for the proximal and distal ends of radius.

  1. Mathematical model in post-mortem estimation of brain edema using morphometric parameters.

    PubMed

    Radojevic, Nemanja; Radnic, Bojana; Vucinic, Jelena; Cukic, Dragana; Lazovic, Ranko; Asanin, Bogdan; Savic, Slobodan

    2017-01-01

    Current autopsy principles for evaluating the existence of brain edema are based on a macroscopic subjective assessment performed by pathologists. The gold standard is a time-consuming histological verification of the presence of the edema. By measuring the diameters of the cranial cavity, as individually determined morphometric parameters, a mathematical model for rapid evaluation of brain edema was created, based on the brain weight measured during the autopsy. A cohort study was performed on 110 subjects, divided into two groups according to the histological presence or absence of (the - deleted from the text) brain edema. In all subjects, the following measures were determined: the volume and the diameters of the cranial cavity (longitudinal and transverse distance and height), the brain volume, and the brain weight. The complex mathematical algorithm revealed a formula for the coefficient ε, which is useful to conclude whether a brain edema is present or not. The average density of non-edematous brain is 0.967 g/ml, while the average density of edematous brain is 1.148 g/ml. The resulting formula for the coefficient ε is (5.79 x longitudinal distance x transverse distance)/brain weight. Coefficient ε can be calculated using measurements of the diameters of the cranial cavity and the brain weight, performed during the autopsy. If the resulting ε is less than 0.9484, it could be stated that there is cerebral edema with a reliability of 98.5%. The method discussed in this paper aims to eliminate the burden of relying on subjective assessments when determining the presence of a brain edema. Copyright © 2016 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  2. Analysis of Images and Spectra of Spacecraft-Induced Radiations

    DTIC Science & Technology

    1992-07-17

    25 s after ignition, since it stems from the initial azimuthal nonuniformity of the propellant burn pattern--as we hypothesize later--, would not be...developing irregular luminosity and succeedin;g few seconds of transversely separated but otherwise relatively smooth glow (refer to Fig. 1) to nonuniform ...appears in the video photographs of the Star 27 burn (see Fig. 15), nonuniform in radiance but with about the same diameter as the later-developing

  3. Variations in the sonographic measurement techniques of BI-RADS 3 breast masses.

    PubMed

    Francisco, Juliana; Jales, Rodrigo Menezes; de Oliveira, André Desuó Bueno; Arguello, Carlos Henrique Francisco; Derchain, Sophie

    2017-06-01

    To evaluate the differences in sonographic (US) distance and volume measurements from different sonologists and identify the optimal parameters to avoid clinically relevant variations in the measurement of BI-RADS 3 breast masses. For this cross-sectional study with prospectively collected data, four physicians with various levels of experience in US, herein called sonologists, performed distance and volume US measurements of 80 masses classified as BI-RADS 3. The Cochran Q test was used to compare the matched sets of rates of clinically relevant variability between all pairs of sonologists' measurements. There were clinically relevant differences between sonologists in the measurements of the longest diameter (range, 17.5-43.7%, p = 0.003), the longest diameter perpendicular to the previous one (anteroposterior diameter) (17.5-33.7%, p = 0.06), the third diameter orthogonal to the plane defined by the previous two (transverse diameter) (28.7-55%, p = 0.001), and at least two of those three diameters (18.7-38.7%, p = 0.015). The smallest clinically relevant differences were observed with volume measurements (range of differences, 6.2-13.7%, p = 0.51). Volume measurement technique was associated with the least variations, whereas distance measurements, which are used routinely, were associated with unacceptable rates of clinically relevant variations. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:252-260, 2017. © 2017 Wiley Periodicals, Inc.

  4. Renal Cell Carcinoma: Comparison of RENAL Nephrometry and PADUA Scores with Maximum Tumor Diameter for Prediction of Local Recurrence after Thermal Ablation.

    PubMed

    Maxwell, Aaron W P; Baird, Grayson L; Iannuccilli, Jason D; Mayo-Smith, William W; Dupuy, Damian E

    2017-05-01

    Purpose To evaluate the performance of the radius, exophytic or endophytic, nearness to collecting system or sinus, anterior or posterior, and location relative to polar lines (RENAL) nephrometry and preoperative aspects and dimensions used for anatomic classification (PADUA) scoring systems and other tumor biometrics for prediction of local tumor recurrence in patients with renal cell carcinoma after thermal ablation. Materials and Methods This HIPAA-compliant study was performed with a waiver of informed consent after institutional review board approval was obtained. A retrospective evaluation of 207 consecutive patients (131 men, 76 women; mean age, 71.9 years ± 10.9) with 217 biopsy-proven renal cell carcinoma tumors treated with thermal ablation was conducted. Serial postablation computed tomography (CT) or magnetic resonance (MR) imaging was used to evaluate for local tumor recurrence. For each tumor, RENAL nephrometry and PADUA scores were calculated by using imaging-derived tumor morphologic data. Several additional tumor biometrics and combinations thereof were also measured, including maximum tumor diameter. The Harrell C index and hazard regression techniques were used to quantify associations with local tumor recurrence. Results The RENAL (hazard ratio, 1.43; P = .003) and PADUA (hazard ratio, 1.80; P < .0001) scores were found to be significantly associated with recurrence when regression techniques were used but demonstrated only poor to fair discrimination according to Harrell C index results (C, 0.68 and 0.75, respectively). Maximum tumor diameter showed the highest discriminatory strength of any individual variable evaluated (C, 0.81) and was also significantly predictive when regression techniques were used (hazard ratio, 2.98; P < .0001). For every 1-cm increase in diameter, the estimated rate of recurrence risk increased by 198%. Conclusion Maximum tumor diameter demonstrates superior performance relative to existing tumor scoring systems and other evaluated biometrics for prediction of local tumor recurrence after renal cell carcinoma ablation. © RSNA, 2016.

  5. Measuring stone volume - three-dimensional software reconstruction or an ellipsoid algebra formula?

    PubMed

    Finch, William; Johnston, Richard; Shaida, Nadeem; Winterbottom, Andrew; Wiseman, Oliver

    2014-04-01

    To determine the optimal method for assessing stone volume, and thus stone burden, by comparing the accuracy of scalene, oblate, and prolate ellipsoid volume equations with three-dimensional (3D)-reconstructed stone volume. Kidney stone volume may be helpful in predicting treatment outcome for renal stones. While the precise measurement of stone volume by 3D reconstruction can be accomplished using modern computer tomography (CT) scanning software, this technique is not available in all hospitals or with routine acute colic scanning protocols. Therefore, maximum diameters as measured by either X-ray or CT are used in the calculation of stone volume based on a scalene ellipsoid formula, as recommended by the European Association of Urology. In all, 100 stones with both X-ray and CT (1-2-mm slices) were reviewed. Complete and partial staghorn stones were excluded. Stone volume was calculated using software designed to measure tissue density of a certain range within a specified region of interest. Correlation coefficients among all measured outcomes were compared. Stone volumes were analysed to determine the average 'shape' of the stones. The maximum stone diameter on X-ray was 3-25 mm and on CT was 3-36 mm, with a reasonable correlation (r = 0.77). Smaller stones (<9 mm) trended towards prolate ellipsoids ('rugby-ball' shaped), stones of 9-15 mm towards oblate ellipsoids (disc shaped), and stones >15 mm towards scalene ellipsoids. There was no difference in stone shape by location within the kidney. As the average shape of renal stones changes with diameter, no single equation for estimating stone volume can be recommended. As the maximum diameter increases, calculated stone volume becomes less accurate, suggesting that larger stones have more asymmetric shapes. We recommend that research looking at stone clearance rates should use 3D-reconstructed stone volumes when available, followed by prolate, oblate, or scalene ellipsoid formulas depending on the maximum stone diameter. © 2013 The Authors. BJU International © 2013 BJU International.

  6. INTERNATIONAL CONFERENCE ON SEMICONDUCTOR INJECTION LASERS SELCO-87: Far-field pattern of transverse modes in LOC structures

    NASA Astrophysics Data System (ADS)

    Petrescu-Prahova, I. B.; Lazanu, S.; Lepşa, M.; Mihailovici, P.

    1988-11-01

    An investigation was made of the emission from GaAlAs large-optical-cavity (LOC) laser heterostructures with an active layer more than 2 μm thick. The far-field radiation pattern, representing a superposition of the fundamental and several higher-order transverse modes, had a central maximum. The gain, mirror losses, near- and far-field patterns of each propagation mode, as well as mode competition were analyzed on the basis of a simple model. The far-field pattern of single modes was determined by selecting separate spectral intervals from the total emission spectrum of the laser.

  7. Annual risks of tuberculous infection in East Nusa Tenggara and Central Java Provinces, Indonesia.

    PubMed

    Bachtiar, A; Miko, T Y; Machmud, R; Besral, B; Yudarini, P; Mehta, F; Chadha, V K; Basri, C; Loprang, F; Jitendra, R

    2009-01-01

    East Nusa Tenggara (NTT) and Central Java Provinces, Indonesia. To estimate the average annual risk of tuberculous infection (ARTI) among school children aged 6-9 years in each province. Children attending Classes 1-4 in 65 schools in NTT and 79 in Central Java, selected by two-stage sampling, were intradermally administered 2 tuberculin units of purified protein derivative RT23 with Tween 80 on the mid-volar aspect of the left forearm. The maximum transverse diameter of induration was measured 72 h later. The analysis was carried out among 5479 satisfactorily test-read children in NTT and 6943 in Central Java. One hundred and fifty-five new sputum smear-positive pulmonary tuberculosis (PTB) cases (78 in NTT and 77 in Central Java) were also tuberculin tested. Based on the frequency distribution of reaction sizes among the children and PTB cases, the prevalence of infection was estimated by the mirror-image method using the modes of tuberculous reactions at 15 and 17 mm. Using the 15 mm mode, ARTI was estimated at 1% in NTT and 0.9% in Central Java. Using the 17 mm mode, ARTI was estimated at 0.5% in NTT and 0.4% in Central Java. Transmission of tuberculous infection may be further reduced by intensification of tuberculosis control efforts.

  8. Diameter Effect Curve and Detonation Front Curvature Measurements for ANFO

    NASA Astrophysics Data System (ADS)

    Catanach, R. A.; Hill, L. G.

    2001-06-01

    Diameter effect and front curvature measurements are reported for rate stick experiments on commercially available prilled ANFO (ammonium nitrate-fuel oil) at ambient temperature. The shots were fired in paper tubes so as to provide minimal confinement. Diameters ranged from 77 mm. (≈ failure diameter) to 200 mm., with the tube length being ten diameters in all cases. Each detonation wave shape was fit with an analytic form, from which the local normal velocity Dn and total curvature κ were generated as a function of radius R, then plotted parametrically to generate a D_n(κ) function. The resulting behavior deviates substantially from that of previous explosives,(Hill,L.G., Bdzil,J.B., and Aslam,T.D., 11^th) Detonation Symposium, 1998^,(Hill,L.G., Bdzil,J.B., Davis,W.C., and Engelke,R., Shock Compression of Condensed Matter, 1999) in which curves for different stick sizes overlay well for small κ but diverge for large κ, and for which κ increases monotonically with R to achieve a maximum value at the charge edge. For ANFO, we find that κ achieves a maximum at an intermediate R and that D_n(κ) curves for different stick sizes are widely separated with no overlap whatsoever.

  9. Transverse Kick Analysis of SSR1 Due to Possible Geometrical Variations in Fabrication

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yakovlev, V.P.; /Fermilab; Awida, M.H.

    2012-05-01

    Due to fabrication tolerance, it is expected that some geometrical variations could happen to the SSR1 cavities of Project X, like small shifts in the transverse direction of the beam pipe or the spoke. It is necessary to evaluate the resultant transverse kick due to these geometrical variations, in order to make sure that they are within the limits of the correctors in the solenoids. In this paper, we report the transverse kick values for various fabrications errors and the sensitivity of the beam to these errors. Transverse kick that could happen in SSR1 cavities due to geometrical variations ofmore » the fabricated cavities from the designed geometry has been analysed and evaluated. From fabrication experience, three kinds of variations were under investigation concerning the alignment of both the beam pipe and spoke with respect to the beam axis. Simulation study has been carried out implementing these variations in the simulation model. CMM measurements of five fabricated SSR1 cavities were carried out to investigate the amount of physical misalignments of the beam pipe and spoke. Bead-pull measurements were also conducted to evaluate the transverse kick values in the fabricated cavities. Simulation and measurements are relatively in good agreement. Maximum kick in the fabricated cavities is within 154 keV that would induce about 1.12 mrad beam deviation, which could be definitely corrected with the 10 mrad specified correctors of Project X.« less

  10. Radiation pressure acceleration: The factors limiting maximum attainable ion energy

    DOE PAGES

    Bulanov, S. S.; Esarey, E.; Schroeder, C. B.; ...

    2016-04-15

    Radiation pressure acceleration (RPA) is a highly efficient mechanism of laser-driven ion acceleration, with near complete transfer of the laser energy to the ions in the relativistic regime. However, there is a fundamental limit on the maximum attainable ion energy, which is determined by the group velocity of the laser. The tightly focused laser pulses have group velocities smaller than the vacuum light speed, and, since they offer the high intensity needed for the RPA regime, it is plausible that group velocity effects would manifest themselves in the experiments involving tightly focused pulses and thin foils. However, in this case,more » finite spot size effects are important, and another limiting factor, the transverse expansion of the target, may dominate over the group velocity effect. As the laser pulse diffracts after passing the focus, the target expands accordingly due to the transverse intensity profile of the laser. Due to this expansion, the areal density of the target decreases, making it transparent for radiation and effectively terminating the acceleration. The off-normal incidence of the laser on the target, due either to the experimental setup, or to the deformation of the target, will also lead to establishing a limit on maximum ion energy.« less

  11. The search for valved conduit tissue grafts for adults (>22 mm): an ultrasonographic study of jugular vein diameters of horses and cattle

    PubMed Central

    Schwarzwald, Colin C; Jenni, Rolf

    2009-01-01

    Background Natural heterologous valved conduits with a diameter greater than 22 mm that can be used for right ventricular outflow tract reconstruction in adults are not commercially available. The purpose of this study was to measure by ultrasonography the maximum diameter of the distended jugular veins of horses and cattle, respectively, to identify a population of animals that would be suitable for post-mortem collection of jugular veins at sizes greater than 22 mm. Methods The study population included 60 Warmblood horses, 25 Freiberger horses, 20 Brown Swiss cows, and 20 Holstein cows (including 10 Holstein and 10 Red Holstein). The maximum cross-sectional diameter of the distended jugular veins was measured at a location half-way between the mandibular angle and the thoracic inlet. The thoracic circumference (heart girth length) was used as a surrogate of body size. The jugular vein diameters of the different populations were compared by analysis of variance and the association between heart girth length and jugular vein diameter was determined in each of the four study populations by linear regression analysis. Results There was considerable individual variation of jugular vein diameters within each of the four study populations. There was no statistically significant relationship between thoracic circumference and jugular vein diameter in any of the populations. The jugular vein diameters of Brown Swiss cows were significantly larger than those of any of the other populations. Warmblood horses had significantly larger jugular vein diameters compared to Freiberger horses. Conclusion The results of this study suggest that the production of bovine or equine xenografts with diameters of greater than 22 mm would be feasible. Differences between species and breeds need to be considered. However, prediction of the jugular vein diameter based on breed and heart girth length in an individual animal is inaccurate. PMID:19678940

  12. 7 CFR 51.320 - Diameter.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Standards for Grades of Apples Definitions § 51.320 Diameter. When measuring for minimum size, “diameter” means the greatest dimension of the apple measured at right angles to a line from stem to blossom end. When measuring for maximum size, “diameter” means the smallest dimension of the apple determined by...

  13. 7 CFR 51.320 - Diameter.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Standards for Grades of Apples Definitions § 51.320 Diameter. When measuring for minimum size, “diameter” means the greatest dimension of the apple measured at right angles to a line from stem to blossom end. When measuring for maximum size, “diameter” means the smallest dimension of the apple determined by...

  14. 7 CFR 51.320 - Diameter.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Standards for Grades of Apples Definitions § 51.320 Diameter. When measuring for minimum size, “diameter” means the greatest dimension of the apple measured at right angles to a line from stem to blossom end. When measuring for maximum size, “diameter” means the smallest dimension of the apple determined by...

  15. Growth and yield of Giant Sequoia

    Treesearch

    David J. Dulitz

    1986-01-01

    Very little information exists concerning growth and yield of giant sequoia (Sequoiadendron giganteum [Lindl.] Buchholz). For old-growth trees, diameter growth is the single factor adding increment since maximum height has been obtained. Diameter growth averages 0.04 inches per year in normal old-growth trees but will fluctuate with changes in the...

  16. Aneurysm Characteristics Associated with the Rupture Risk of Intracranial Aneurysms: A Self-Controlled Study.

    PubMed

    Kang, Huibin; Ji, Wenjun; Qian, Zenghui; Li, Youxiang; Jiang, Chuhan; Wu, Zhongxue; Wen, Xiaolong; Xu, Wenjuan; Liu, Aihua

    2015-01-01

    This study analyzed the rupture risk of intracranial aneurysms (IAs) according to aneurysm characteristics by comparing the differences between two aneurysms in different locations within the same patient. We utilized this self-controlled model to exclude potential interference from all demographic factors to study the risk factors related to IA rupture. A total of 103 patients were diagnosed with IAs between January 2011 and April 2015 and were enrolled in this study. All enrolled patients had two IAs. One IA (the case) was ruptured, and the other (the control) was unruptured. Aneurysm characteristics, including the presence of a daughter sac, the aneurysm neck, the parent artery diameter, the maximum aneurysm height, the maximum aneurysm width, the location, the aspect ratio (AR, maximum perpendicular height/average neck diameter), the size ratio (SR, maximum aneurysm height/average parent diameter) and the width/height ratio (WH ratio, maximum aneurysm width/maximum aneurysm height), were collected and analyzed to evaluate the rupture risks of the two IAs within each patient and to identify the independent risk factors associated with IA rupture. Multivariate, conditional, backward, stepwise logistic regression analysis was performed to identify the independent risk factors associated with IA rupture. The multivariate analysis identified the presence of a daughter sac (odds ratio [OR], 13.80; 95% confidence interval [CI], 1.65-115.87), a maximum aneurysm height ≥7 mm (OR, 4.80; 95% CI, 1.21-18.98), location on the posterior communicating artery (PCOM) or anterior communicating artery (ACOM; OR, 3.09; 95% CI, 1.34-7.11) and SR (OR, 2.13; 95% CI, 1.16-3.91) as factors that were significantly associated with IA rupture. The presence of a daughter sac, the maximum aneurysm height, PCOM or ACOM locations and SR (>1.5±0.7) of unruptured IAs were significantly associated with IA rupture.

  17. Nozzle dam having a unitary plug

    DOEpatents

    Veronesi, L.; Wepfer, R.M.

    1992-12-15

    Apparatus for sealing the primary-side coolant flow nozzles of a nuclear steam generator is disclosed. The steam generator has relatively small diameter manway openings for providing access to the interior of the steam generator including the inside surface of each nozzle, the manway openings having a diameter substantially less than the inside diameter of each nozzle. The apparatus includes a bracket having an outside surface for matingly sealingly engaging the inside surface of the nozzle. The bracket also has a plurality of openings longitudinally therethrough and a plurality of slots transversely therein in communication with each opening. A plurality of unitary plugs sized to pass through the manway opening are matingly sealingly disposed in each opening of the bracket for sealingly plugging each opening. Each plug includes a plurality of arms operable to engage the slots of the bracket for connecting each plug to the bracket, so that the nozzle is sealed as the plugs seal the openings and are connected to the bracket. 16 figs.

  18. Nozzle dam having a unitary plug

    DOEpatents

    Veronesi, Luciano; Wepfer, Robert M.

    1992-01-01

    Apparatus for sealing the primary-side coolant flow nozzles of a nuclear steam generator. The steam generator has relatively small diameter manway openings for providing access to the interior of the steam generator including the inside surface of each nozzle, the manway openings having a diameter substantially less than the inside diameter of each nozzle. The apparatus includes a bracket having an outside surface for matingly sealingly engaging the inside surface of the nozzle. The bracket also has a plurality of openings longitudinally therethrough and a plurality of slots transversely therein in communication with each opening. A plurality of unitary plugs sized to pass through the manway opening are matingly sealingly disposed in each opening of the bracket for sealingly plugging each opening. Each plug includes a plurality of arms operable to engage the slots of the bracket for connecting each plug to the bracket, so that the nozzle is sealed as the plugs seal the openings and are connected to the bracket.

  19. Influence of G-forces and hypodynamia on the portal system of the liver

    NASA Technical Reports Server (NTRS)

    Drozdova, A. V.

    1975-01-01

    Longitudinally and transversely applied g-forces as intolerable levels cause damage to the interlobular veins of the liver, with maximum damage caused by dorso-ventral g-force application. The portal vein system is more resilient with respect to g-forces at the limit of tolerance.

  20. Plasma studies of the permanent magnet electron cyclotron resonance ion source at Peking University.

    PubMed

    Ren, H T; Peng, S X; Xu, Y; Zhao, J; Lu, P N; Chen, J; Zhang, A L; Zhang, T; Guo, Z Y; Chen, J E

    2014-02-01

    At Peking University (PKU) we have developed several 2.45 GHz Permanent Magnet Electron Cyclotron Resonance ion sources for PKUNIFTY, SFRFQ, Coupled RFQ&SFRFQ, and Dielectric-Wall Accelerator (DWA) projects (respectively, 50 mA of D(+), 10 mA of O(+), 10 mA of He(+), and 50 mA of H(+)). In order to improve performance of these ion sources, it is necessary to better understand the principal factors that influence the plasma density and the atomic ion fraction. Theoretical analysis about microwave transmission and cut-off inside the discharge chamber were carried out to study the influence of the discharge chamber diameters. As a consequence, experimental studies on plasma density and ion fraction with different discharge chamber sizes have been carried out. Due to the difficulties in measuring plasma density inside the discharge chamber, the output beam current was measured to reflect the plasma density. Experimental results show that the plasma density increases to the maximum and then decreases significantly as the diameter changed from 64 mm to 30 mm, and the atomic ion fraction has the same tendency. The maximum beam intensity was obtained with the diameter of 35 mm, but the maximum atomic ion fraction with a diameter of 40 mm. The experimental results are basically accordant with the theoretical calculation. Details are presented in this paper.

  1. Growth of ponderosa pine seedlings as affected by air pollution

    NASA Astrophysics Data System (ADS)

    Momen, B.; Anderson, P. D.; Houpis, J. L. J.; Helms, J. A.

    The effect of air pollution on seedling survival and competitive ability is important to natural and artificial regeneration of forest trees. Although biochemical and physiological processes are sensitive indicators of pollution stress, the cumulative effects of air pollutants on seedling vigor and competitive ability may be assessed directly from whole-plant growth characteristics such as diameter, height, and photosynthetic area. A few studies that have examined intraspecific variation in seedling response to air pollution indicate that genotypic differences are important in assessing potential effects of air pollution on forest regeneration. Here, we studied the effects of acid rain (no-rain, pH 5.1 rain, pH 3.0 rain) and ozone (filtered, ambient, twice-ambient) in the field on height, diameter, volume, the height:diameter ratio, maximum needle length, and time to reach maximum needle length in seedlings of three families of ponderosa pine ( Pinus ponderosa Dougl. ex Laws). Seedling diameter, height, volume, and height:diameter ratio related significantly to their pre-treatment values. Twice-ambient ozone decreased seedling diameter compared with ozone-filtered air. A significant family-by-ozone interaction was detected for seedling height, as the height of only one of the three families was decreased by twice-ambient ozone compared with the ambient level. Seedling diameter was larger and the height:diameter ratio was smaller under pH 3.0 rain compared to either the no-rain or the pH 5.1-rain treatment. This suggests greater seedling vigor, perhaps due to a foliar fertilization effect of the pH 3.0 rain.

  2. Effects of uniform surface roughness on vortex-induced vibration of towed vertical cylinders

    NASA Astrophysics Data System (ADS)

    Kiu, K. Y.; Stappenbelt, B.; Thiagarajan, K. P.

    2011-09-01

    The present study was motivated by a desire to understand the vortex-induced vibration (VIV) of cylindrical offshore structures such as spars in strong currents. In particular, the consequences of marine growth on the surface as well as natural surface roughness that occurs with years in service are studied. Of special interest is the effect of surface roughness on the response amplitudes and the forces experienced by these structures while undergoing VIV. The experimental apparatus employed for the present study consisted of an elastically mounted rigid vertical cylinder with no end plates, towed along the length of a water tank. The cylinder was attached to a parallel linkage mechanism allowing motion in the transverse direction only. The cylinder surface was covered by sandpapers with known mean particle diameters, thus providing controlled values of roughness coefficient from 0.28×10 -3 to 1.38×10 -2. The tests covered the subcritical range of Reynolds number from 1.7×10 4 to 8.3×10 4, and a reduced velocity range from 4 to 16. It was found that as the roughness of the cylinder was increased the maximum response amplitude and the maximum mean drag coefficient decreased, levelling off to constant values. The onset of lock-in was progressively delayed for rougher cylinders, and the width of the lock-in region showed remarkable reduction at higher roughness values. The Strouhal number was found to display a modest increase with roughness. The dynamic mean drag of the rough cylinders was also found to be lower than that for a smooth cylinder. It is felt that uniform roughness such as caused in marine environments may act favorably to lower VIV incidence and effects in the range of Reynolds number tested.

  3. The Characteristics of Thin Magnetic Flux Tubes in the Lower Solar Atmosphere Observed by Hinode/SOT in the G band and in Ca II H Bright Points

    NASA Astrophysics Data System (ADS)

    Xiong, Jianping; Yang, Yunfei; Jin, Chunlan; Ji, Kaifan; Feng, Song; Wang, Feng; Deng, Hui; Hu, Yu

    2017-12-01

    Photospheric bright points (PBPs) and chromospheric bright points (CBPs) reflect the cross sections of magnetic flux tubes at different heights of the lower solar atmosphere. We aim to study the fine 3D structures and transportation dynamics of the magnetic flux tubes using G-band and simultaneous Ca II H image-series from the Solar Optical Telescope (SOT) on board Hinode. A 3D track-while-detect method is proposed to detect and track PBPs and CBPs. The mean values of equivalent diameters, maximum intensity contrasts, transverse velocities, motion ranges, motion types, and diffusion indices of PBPs and CBPs are 180 ± 20 and 210 ± 30 km, 1.0+/- 0.1< {I}{QS\\_G}> and 1.2+/- 0.1< {I}{QS\\Ca}> , 1.6 ± 0.8 and 2.7 ± 1.4 km s‑1, 1.5 ± 0.6 and 1.7 ± 0.8, 0.8 ± 0.2 and 0.6 ± 0.2, and 1.7 ± 0.7 and 1.3 ± 0.7, respectively. Moreover, the ratios of each CBP characteristics to its corresponding PBP are derived to explore the change rates of the flux tubes. The corresponding ratios are 1.2 ± 0.2, 1.2 ± 0.1, 1.9 ± 0.1, 1.4 ± 0.3, 0.7 ± 0.2, and 0.9 ± 0.4, respectively. The statistical results imply that the majority magnetic flux tubes expand slightly with increasing solar height, look brighter than their surroundings, show a higher transverse velocity, a wider motion range, and a more erratic path, but the majority of the flux tubes diffuse slightly slower. The phenomenon might be explained by the conservation of momentum combined with a decrease in density. The more erratic path leads to a swing or twist of the flux tubes and therefore guides magnetohydrodynamic waves.

  4. Non-invasive vascular radial/circumferential strain imaging and wall shear rate estimation using video images of diagnostic ultrasound.

    PubMed

    Wan, Jinjin; He, Fangli; Zhao, Yongfeng; Zhang, Hongmei; Zhou, Xiaodong; Wan, Mingxi

    2014-03-01

    The aim of this work was to develop a convenient method for radial/circumferential strain imaging and shear rate estimation that could be used as a supplement to the current routine screening for carotid atherosclerosis using video images of diagnostic ultrasound. A reflection model-based correction for gray-scale non-uniform distribution was applied to B-mode video images before strain estimation to improve the accuracy of radial/circumferential strain imaging when applied to vessel transverse cross sections. The incremental and cumulative radial/circumferential strain images can then be calculated based on the displacement field between consecutive B-mode images. Finally, the transverse Doppler spectra acquired at different depths along the vessel diameter were used to construct the spatially matched instantaneous wall shear values in a cardiac cycle. Vessel phantom simulation results revealed that the signal-to-noise ratio and contrast-to-noise ratio of the radial and circumferential strain images were increased by 2.8 and 5.9 dB and by 2.3 and 4.4 dB, respectively, after non-uniform correction. Preliminary results for 17 patients indicated that the accuracy of radial/circumferential strain images was improved in the lateral direction after non-uniform correction. The peak-to-peak value of incremental strain and the maximum cumulative strain for calcified plaques are evidently lower than those for other plaque types, and the echolucent plaques had higher values, on average, than the mixed plaques. Moreover, low oscillating wall shear rate values, found near the plaque and stenosis regions, are closely related to plaque formation. In conclusion, the method described can provide additional valuable results as a supplement to the current routine ultrasound examination for carotid atherosclerosis and, therefore, has significant potential as a feasible screening method for atherosclerosis diagnosis in the future. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  5. Influence of knee flexion angle and transverse drill angle on creation of femoral tunnels in double-bundle anterior cruciate ligament reconstruction using the transportal technique: Three-dimensional computed tomography simulation analysis.

    PubMed

    Choi, Chong Hyuk; Kim, Sung-Jae; Chun, Yong-Min; Kim, Sung-Hwan; Lee, Su-Keon; Eom, Nam-Kyu; Jung, Min

    2018-01-01

    The purpose of this study was to find appropriate flexion angle and transverse drill angle for optimal femoral tunnels of anteromedial (AM) bundle and posterolateral (PL) bundle in double-bundle ACL reconstruction using transportal technique. Thirty three-dimensional knee models were reconstructed. Knee flexion angles were altered from 100° to 130° at intervals of 10°. Maximum transverse drill angle (MTA), MTA minus 10° and 20° were set up. Twelve different tunnels were determined by four flexion angles and three transverse drill angles for each bundle. Tunnel length, wall breakage, inter-tunnel communication and graft-bending angle were assessed. Mean tunnel length of AM bundle was >30mm at 120° and 130° of flexion in all transverse drill angles. Mean tunnel length of PL bundle was >30mm during every condition. There were ≥1 cases of wall breakage except at 120° and 130° of flexion with MTA for AM bundle. There was no case of wall breakage for PL bundle. Considering inter-tunnel gap of >2mm without communication and obtuse graft-bending angle, 120° of flexion and MTA could be recommended as optimal condition for femoral tunnels of AM and PL bundles. Flexion angle and transverse drill angle had combined effect on femoral tunnel in double-bundle ACL reconstruction using transportal technique. Achieving flexion angle of 120° and transverse drill angle close to the medial femoral condyle could be recommended as optimal condition for femoral tunnels of AM and PL bundles to avoid insufficient tunnel length, wall breakage, inter-tunnel communication and acute graft-bending angle. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Low cost composite materials for wind energy conversion systems

    NASA Technical Reports Server (NTRS)

    Weingart, O.

    1980-01-01

    A winding process utilizing a low-cost E-glass fabric called transverse-filament tape for low-cost production of wind turbine generators (WTG) is described. The process can be carried out continuously at high speed to produce large one-piece parts with tapered wall thicknesses on a tapered mandrel. It is being used to manufacture blades for the NASA/DOE 200-ft-diameter MOD-1 WTG and Rockwell/DOE 40-kW small wind energy conversion system (SWECS).

  7. Challenges of Zinc-Specific Transrectal Fluorescence Tomography to Detect Prostate Cancer

    DTIC Science & Technology

    2013-12-01

    swept-source and a 20mm-diameter transverse-imaging intra-lumenal applicator with 7 source and 8 detector channels placed in a liquid phantom. Higher...3. RESULTS ON PHANTOM IMAGING The performance of this system configuration is evaluated by using liquid and solid phantoms. 3.1 Experiments setup... direc - tions. For each possible future location of the detector, the photon fluence rate at that position is compared with the case in the semi

  8. The Influence of Initial and Boundary Conditions on Gaseous Detonation Waves.

    DTIC Science & Technology

    1985-09-01

    in large diameter tubes. A theory dealing with the origin of spin was later advanced by Bone, Fraser and Wheeler (1935) based on Schlieren records...acoustic theories for the prediction of the spinning frequency of the transverse vibrations in and behind the reaction zone. The frequency of the single-head...Frazer simply corresponded to ’ other higher acoustic modes. An excellent description of the fine wechani- cal details of low-mode spinning detonations is

  9. Effects of an oil spill on the leaf anatomical characteristics of a beach plant (Terminalia catappa L.).

    PubMed

    Punwong, Paramita; Juprasong, Yotin; Traiperm, Paweena

    2017-09-01

    This study investigated the short-term impacts of an oil spill on the leaf anatomical structures of Terminalia catappa L. from crude oil leakage in Rayong province, Thailand, in 2013. Approximately 3 weeks after the oil spill, leaves of T. catappa were collected along the coastline of Rayong from one affected site, five adjacent sites, and a control site. Slides of the leaf epidermis were prepared by the peeling method, while leaf and petiole transverse sections were prepared by paraffin embedding. Cell walls of adaxial epidermal cell on leaves in the affected site were straight instead of the jigsaw shape found in leaves from the adjacent and control sites. In addition, the stomatal index of the abaxial leaf surface was significantly lower in the affected site. Leaf and petiole transverse sections collected from the affected site showed increased cuticle thickness, epidermal cell diameter on both sides, and palisade mesophyll thickness; in contrast, vessel diameter and spongy mesophyll thickness were reduced. These significant changes in the leaf anatomy of T. catappa correspond with previous research and demonstrate the negative effects of oil spill pollution on plants. The anatomical changes of T. catappa in response to crude oil pollution are discussed as a possible indicator of pollution and may be used in monitoring crude oil pollution.

  10. Fabrication and characterization of disordered polymer optical fibers for transverse Anderson localization of light.

    PubMed

    Karbasi, Salman; Frazier, Ryan J; Mirr, Craig R; Koch, Karl W; Mafi, Arash

    2013-07-29

    We develop and characterize a disordered polymer optical fiber that uses transverse Anderson localization as a novel waveguiding mechanism. The developed polymer optical fiber is composed of 80,000 strands of poly (methyl methacrylate) (PMMA) and polystyrene (PS) that are randomly mixed and drawn into a square cross section optical fiber with a side width of 250 μm. Initially, each strand is 200 μm in diameter and 8-inches long. During the mixing process of the original fiber strands, the fibers cross over each other; however, a large draw ratio guarantees that the refractive index profile is invariant along the length of the fiber for several tens of centimeters. The large refractive index difference of 0.1 between the disordered sites results in a small localized beam radius that is comparable to the beam radius of conventional optical fibers. The input light is launched from a standard single mode optical fiber using the butt-coupling method and the near-field output beam from the disordered fiber is imaged using a 40X objective and a CCD camera. The output beam diameter agrees well with the expected results from the numerical simulations. The disordered optical fiber presented in this work is the first device-level implementation of 2D Anderson localization, and can potentially be used for image transport and short-haul optical communication systems.

  11. Fabrication and Characterization of Disordered Polymer Optical Fibers for Transverse Anderson Localization of Light

    PubMed Central

    Karbasi, Salman; Frazier, Ryan J.; Mirr, Craig R.; Koch, Karl W.; Mafi, Arash

    2013-01-01

    We develop and characterize a disordered polymer optical fiber that uses transverse Anderson localization as a novel waveguiding mechanism. The developed polymer optical fiber is composed of 80,000 strands of poly (methyl methacrylate) (PMMA) and polystyrene (PS) that are randomly mixed and drawn into a square cross section optical fiber with a side width of 250 μm. Initially, each strand is 200 μm in diameter and 8-inches long. During the mixing process of the original fiber strands, the fibers cross over each other; however, a large draw ratio guarantees that the refractive index profile is invariant along the length of the fiber for several tens of centimeters. The large refractive index difference of 0.1 between the disordered sites results in a small localized beam radius that is comparable to the beam radius of conventional optical fibers. The input light is launched from a standard single mode optical fiber using the butt-coupling method and the near-field output beam from the disordered fiber is imaged using a 40X objective and a CCD camera. The output beam diameter agrees well with the expected results from the numerical simulations. The disordered optical fiber presented in this work is the first device-level implementation of 2D Anderson localization, and can potentially be used for image transport and short-haul optical communication systems. PMID:23929276

  12. Effects of injection pressure variation on mixing in a cold supersonic combustor with kerosene fuel

    NASA Astrophysics Data System (ADS)

    Liu, Wei-Lai; Zhu, Lin; Qi, Yin-Yin; Ge, Jia-Ru; Luo, Feng; Zou, Hao-Ran; Wei, Min; Jen, Tien-Chien

    2017-10-01

    Spray jet in cold kerosene-fueled supersonic flow has been characterized under different injection pressures to assess the effects of the pressure variation on the mixing between incident shock wave and transverse cavity injection. Based on the real scramjet combustor, a detailed computational fluid dynamics model is developed. The injection pressures are specified as 0.5, 1.0, 2.0, 3.0 and 4.0 MPa, respectively, with the other constant operation parameters (such as the injection diameter, angle and velocity). A three dimensional Couple Level Set & Volume of Fluids approach incorporating an improved Kelvin-Helmholtz & Rayleigh-Taylor model is used to investigate the interaction between kerosene and supersonic air. The numerical simulations primarily concentrate on penetration depth, span expansion area, angle of shock wave and sauter mean diameter distribution of the kerosene droplets with/without evaporation. Validation has been implemented by comparing the calculated against the measured in literature with good qualitative agreement. Results show that the penetration depth, span-wise angle and expansion area of the transverse cavity jet are all increased with the injection pressure. However, when the injection pressure is further increased, the value in either penetration depth or expansion area increases appreciably. This study demonstrates the feasibility and effectiveness of the combination of Couple Level Set & Volume of Fluids approach and an improved Kelvin-Helmholtz & Rayleigh-Taylor model, in turn providing insights into scramjet design improvement.

  13. Assessment of the effect of deviated nasal septum on the structure of nasal cavity.

    PubMed

    Wang, Junguo; Dou, Xin; Liu, Dingding; Song, Panpan; Qian, Xiaoyun; Wang, Shoulin; Gao, Xia

    2016-06-01

    The present study was aimed to investigate the effects of DNS on the structure of nasal cavity. The paranasal sinus coronal view CT of 108 patients with DNS and 129 hospitalized patients without DNS was retrospectively analyzed. The transverse diameter of nasal cavity (a), transverse diameter of nasal cavity and paranasal sinus (b), angle between maxillary and palatal bone, interalveolar distance, and maxillary rotation distance were measured. The ratio of a/b in experimental group was 0.367 ± 0.006 which was significantly (P = 0.0023) less than that in control group (0.391 ± 0.005). For the angle between maxillary and palatal bone, there was no significant difference found between DNS and control group for both right and left sides. The interalveolar distance was 40.75 mm in experimental group, and 38.8 mm in control (P = 0.0002). For the maxillary rotation distance, findings were considered as significant (P < 0.0001) in experimental group (11.25 mm) compared with control (10.1 mm). The present study demonstrates that long-term DNS affects the development of nasal cavity and paranasal sinus, as well as increases the interalveolar distance and maxillary rotation distance. These influences may be caused by the alteration of airflow inside the nasal cavities.

  14. Characteristics and performance of a superconducting bumpy-torus magnet facility for plasma research

    NASA Technical Reports Server (NTRS)

    Roth, J. R.; Holmes, A. D.; Keller, T. A.; Krawczonek, W. M.

    1973-01-01

    The NASA Lewis bumpy-torus facility consists of 12 superconducting coils, each 19 cm i.d. and capable of 3.0 T on its axis. The coils are equally spaced around a toroidal array with a major diameter of 1.52 m; they are mounted with the major axis of the torus vertical in a single vacuum tank 2.6 m in diameter. Tests of the facility mapped out its magnetic, cryogenic, vacuum, mechanical, and electrical performance. The design value of the maximum magnetic field on the magnetic axis, 3.0 T, was reached and exceeded. A maximum magnetic field of 3.23 T was held for a period of 60 minutes. When the coils were charged to a maximum magnetic field of 3.35 T, the coil system went normal without apparent damage or degradation of performance.

  15. Oriented clonal cell dynamics enables accurate growth and shaping of vertebrate cartilage

    PubMed Central

    Kaucka, Marketa; Zikmund, Tomas; Tesarova, Marketa; Gyllborg, Daniel; Hellander, Andreas; Jaros, Josef; Kaiser, Jozef; Petersen, Julian; Szarowska, Bara; Newton, Phillip T; Dyachuk, Vyacheslav; Li, Lei; Qian, Hong; Johansson, Anne-Sofie; Mishina, Yuji; Currie, Joshua D; Tanaka, Elly M; Erickson, Alek; Dudley, Andrew; Brismar, Hjalmar; Southam, Paul; Coen, Enrico; Chen, Min; Weinstein, Lee S; Hampl, Ales; Arenas, Ernest; Chagin, Andrei S; Fried, Kaj; Adameyko, Igor

    2017-01-01

    Cartilaginous structures are at the core of embryo growth and shaping before the bone forms. Here we report a novel principle of vertebrate cartilage growth that is based on introducing transversally-oriented clones into pre-existing cartilage. This mechanism of growth uncouples the lateral expansion of curved cartilaginous sheets from the control of cartilage thickness, a process which might be the evolutionary mechanism underlying adaptations of facial shape. In rod-shaped cartilage structures (Meckel, ribs and skeletal elements in developing limbs), the transverse integration of clonal columns determines the well-defined diameter and resulting rod-like morphology. We were able to alter cartilage shape by experimentally manipulating clonal geometries. Using in silico modeling, we discovered that anisotropic proliferation might explain cartilage bending and groove formation at the macro-scale. DOI: http://dx.doi.org/10.7554/eLife.25902.001 PMID:28414273

  16. Numerical study of axial turbulent flow over long cylinders

    NASA Technical Reports Server (NTRS)

    Neves, J. C.; Moin, P.; Moser, R. D.

    1991-01-01

    The effects of transverse curvature are investigated by means of direct numerical simulations of turbulent axial flow over cylinders. Two cases of Reynolds number of about 3400 and layer-thickness-to-cylinder-radius ratios of 5 and 11 were simulated. All essential turbulence scales were resolved in both calculations, and a large number of turbulence statistics were computed. The results are compared with the plane channel results of Kim et al. (1987) and with experiments. With transverse curvature the skin friction coefficient increases and the turbulence statistics, when scaled with wall units, are lower than in the plane channel. The momentum equation provides a scaling that collapses the cylinder statistics, and allows the results to be interpreted in light of the plane channel flow. The azimuthal and radial length scales of the structures in the flow are of the order of the cylinder diameter. Boomerang-shaped structures with large spanwise length scales were observed in the flow.

  17. Metacystis borrori n. sp. (Ciliophora: Metacystidae) on the seagrass Thalassia testudinum.

    PubMed

    Aladro-Lubel, M A Antonieta; Martinez-Murillo, M A Esther

    2003-01-01

    A new epibiontic ciliate of the genus Metacystis is described on the seagrass Thalassia testudinum of the coral reef lagoons of Veracruz, Mexico. The ciliate was studied in living and stained specimens and under the scanning electron microscope. The cell body (10-35 x 10-18 microm in vivo) is transversely annulated (4-6 rings). The somatic ciliature consists of 22-30 longitudinal kineties, and patterned as 5-7 transverse kineties. The circumoral kinety is composed of kinetosomes closely spaced. The macronucleus diameter measures about 3-7 microm. The lorica (18-61 x 11-26 microm) has the posterior end round to conical or irregular with mucoid filaments. This prostomatid colonizes both natural and artificial substrates placed in an aquarium. Metacystis borrori n. sp. is a species that forms part of the ciliate community on Thalassia testudinum with a temperature range of 21-26 degrees C and a salinity of 32-40 per thousand.

  18. A preliminary mechanical property and stress corrosion evaluation of VIM-VAR work strengthened and direct aged Inconel 718 bar material

    NASA Technical Reports Server (NTRS)

    Montano, J. W.

    1987-01-01

    This report presents a preliminary mechanical property and stress corrosion evaluation of double melted (vacuum induction melted (VIM), and vacuum arc remelted (VAR)), solution treated, work strengthened and direct aged Inconel 718 alloy bar (5.50 in. (13.97 cm) diameter). Two sets of tensile specimens, one direct single aged and the other direct double aged, were tested at ambient temperature in both the longitudinal and transverse directions. Longitudinal tensile and yield strengths in excess of 200 ksi (1378.96 MPa) and 168 ksi (1158.33 MPa), respectively, were realized at ambient temperature, for the direct double aged specimen. No failures occurred in the single or double edged longitudinal and transverse tensile specimens stressed to 75 and 100 percent of their respective yield strengths and exposed to a salt fog environment for 180 days. Tensile tests performed after the stress corrosion test showed no mechanical property degradation.

  19. Transverse stress induced LP 02-LP 21 modal interference of stimulated Raman scattered light in a few-mode optical fiber

    NASA Astrophysics Data System (ADS)

    Sharma, A.; Posey, R.

    1996-02-01

    Four-photon mixing followed by stimulated Raman scattering is observed in LP 02 mode in a 7.9 μm core diameter optical fiber. A localized transverse stress efficiency couples LP 02 to the LP 21 mode with a macroscopic beat length of 1.8 mm. LP 02-LP 21 modal interference is investigated by detecting the 550-590 nm SRS through a pinhole in the far field exit plane. Quantitative explanation of wavelength dependent intensity modulation results in a precise experimental determination of {∂[β 02(λ) - β 21(λ)] }/{∂λ}, for mode-propagation constants β02( λ) and β21( λ) of LP 02 and LP 21 modes respectively, as well as Δ, the relative core-cladding refractive index difference. The LP 02-LP 21 modal interference is used for sensing of temperature between 50-300°C.

  20. The performance of the jet trigger for the ATLAS detector during 2011 data taking

    NASA Astrophysics Data System (ADS)

    Aad, G.; Abbott, B.; Abdallah, J.; Abdinov, O.; Abeloos, B.; Aben, R.; Abolins, M.; AbouZeid, O. S.; Abraham, N. L.; Abramowicz, H.; Abreu, H.; Abreu, R.; Abulaiti, Y.; Acharya, B. S.; Adamczyk, L.; Adams, D. L.; Adelman, J.; Adomeit, S.; Adye, T.; Affolder, A. A.; Agatonovic-Jovin, T.; Agricola, J.; Aguilar-Saavedra, J. A.; Ahlen, S. P.; Ahmadov, F.; Aielli, G.; Akerstedt, H.; Åkesson, T. P. A.; Akimov, A. V.; Alberghi, G. L.; Albert, J.; Albrand, S.; Verzini, M. J. Alconada; Aleksa, M.; Aleksandrov, I. N.; Alexa, C.; Alexander, G.; Alexopoulos, T.; Alhroob, M.; Aliev, M.; Alimonti, G.; Alison, J.; Alkire, S. P.; Allbrooke, B. M. M.; Allen, B. W.; Allport, P. P.; Aloisio, A.; Alonso, A.; Alonso, F.; Alpigiani, C.; Gonzalez, B. Alvarez; Piqueras, D. Álvarez; Alviggi, M. G.; Amadio, B. T.; Amako, K.; Coutinho, Y. Amaral; Amelung, C.; Amidei, D.; Santos, S. P. Amor Dos; Amorim, A.; Amoroso, S.; Amram, N.; Amundsen, G.; Anastopoulos, C.; Ancu, L. S.; Andari, N.; Andeen, T.; Anders, C. F.; Anders, G.; Anders, J. K.; Anderson, K. J.; Andreazza, A.; Andrei, V.; Angelidakis, S.; Angelozzi, I.; Anger, P.; Angerami, A.; Anghinolfi, F.; Anisenkov, A. V.; Anjos, N.; Annovi, A.; Antonelli, M.; Antonov, A.; Antos, J.; Anulli, F.; Aoki, M.; Bella, L. Aperio; Arabidze, G.; Arai, Y.; Araque, J. P.; Arce, A. T. H.; Arduh, F. A.; Arguin, J.-F.; Argyropoulos, S.; Arik, M.; Armbruster, A. J.; Armitage, L. J.; Arnaez, O.; Arnold, H.; Arratia, M.; Arslan, O.; Artamonov, A.; Artoni, G.; Artz, S.; Asai, S.; Asbah, N.; Ashkenazi, A.; Åsman, B.; Asquith, L.; Assamagan, K.; Astalos, R.; Atkinson, M.; Atlay, N. B.; Augsten, K.; Avolio, G.; Axen, B.; Ayoub, M. K.; Azuelos, G.; Baak, M. A.; Baas, A. E.; Baca, M. J.; Bachacou, H.; Bachas, K.; Backes, M.; Backhaus, M.; Bagiacchi, P.; Bagnaia, P.; Bai, Y.; Baines, J. T.; Baker, O. K.; Baldin, E. M.; Balek, P.; Balestri, T.; Balli, F.; Balunas, W. K.; Banas, E.; Banerjee, Sw.; Bannoura, A. A. E.; Barak, L.; Barberio, E. L.; Barberis, D.; Barbero, M.; Barillari, T.; Barklow, T.; Barlow, N.; Barnes, S. L.; Barnett, B. M.; Barnett, R. M.; Barnovska, Z.; Baroncelli, A.; Barone, G.; Barr, A. J.; Navarro, L. Barranco; Barreiro, F.; da Costa, J. Barreiro Guimarães; Bartoldus, R.; Barton, A. E.; Bartos, P.; Basalaev, A.; Bassalat, A.; Basye, A.; Bates, R. L.; Batista, S. J.; Batley, J. R.; Battaglia, M.; Bauce, M.; Bauer, F.; Bawa, H. S.; Beacham, J. B.; Beattie, M. D.; Beau, T.; Beauchemin, P. H.; Bechtle, P.; Beck, H. P.; Becker, K.; Becker, M.; Beckingham, M.; Becot, C.; Beddall, A. J.; Beddall, A.; Bednyakov, V. A.; Bedognetti, M.; Bee, C. P.; Beemster, L. J.; Beermann, T. A.; Begel, M.; Behr, J. K.; Belanger-Champagne, C.; Bell, A. S.; Bella, G.; Bellagamba, L.; Bellerive, A.; Bellomo, M.; Belotskiy, K.; Beltramello, O.; Belyaev, N. L.; Benary, O.; Benchekroun, D.; Bender, M.; Bendtz, K.; Benekos, N.; Benhammou, Y.; Noccioli, E. Benhar; Benitez, J.; Garcia, J. A. Benitez; Benjamin, D. P.; Bensinger, J. R.; Bentvelsen, S.; Beresford, L.; Beretta, M.; Berge, D.; Kuutmann, E. Bergeaas; Berger, N.; Berghaus, F.; Beringer, J.; Berlendis, S.; Bernard, N. R.; Bernius, C.; Bernlochner, F. U.; Berry, T.; Berta, P.; Bertella, C.; Bertoli, G.; Bertolucci, F.; Bertram, I. A.; Bertsche, C.; Bertsche, D.; Besjes, G. J.; Bylund, O. Bessidskaia; Bessner, M.; Besson, N.; Betancourt, C.; Bethke, S.; Bevan, A. J.; Bhimji, W.; Bianchi, R. M.; Bianchini, L.; Bianco, M.; Biebel, O.; Biedermann, D.; Bielski, R.; Biesuz, N. V.; Biglietti, M.; De Mendizabal, J. Bilbao; Bilokon, H.; Bindi, M.; Binet, S.; Bingul, A.; Bini, C.; Biondi, S.; Bjergaard, D. M.; Black, C. W.; Black, J. E.; Black, K. M.; Blackburn, D.; Blair, R. E.; Blanchard, J.-B.; Blanco, J. E.; Blazek, T.; Bloch, I.; Blocker, C.; Blum, W.; Blumenschein, U.; Blunier, S.; Bobbink, G. J.; Bobrovnikov, V. S.; Bocchetta, S. S.; Bocci, A.; Bock, C.; Boehler, M.; Boerner, D.; Bogaerts, J. A.; Bogavac, D.; Bogdanchikov, A. G.; Bohm, C.; Boisvert, V.; Bold, T.; Boldea, V.; Boldyrev, A. S.; Bomben, M.; Bona, M.; Boonekamp, M.; Borisov, A.; Borissov, G.; Bortfeldt, J.; Bortoletto, D.; Bortolotto, V.; Bos, K.; Boscherini, D.; Bosman, M.; Sola, J. D. Bossio; Boudreau, J.; Bouffard, J.; Bouhova-Thacker, E. V.; Boumediene, D.; Bourdarios, C.; Boutle, S. K.; Boveia, A.; Boyd, J.; Boyko, I. R.; Bracinik, J.; Brandt, A.; Brandt, G.; Brandt, O.; Bratzler, U.; Brau, B.; Brau, J. E.; Braun, H. M.; Madden, W. D. Breaden; Brendlinger, K.; Brennan, A. J.; Brenner, L.; Brenner, R.; Bressler, S.; Bristow, T. M.; Britton, D.; Britzger, D.; Brochu, F. M.; Brock, I.; Brock, R.; Brooijmans, G.; Brooks, T.; Brooks, W. K.; Brosamer, J.; Brost, E.; Broughton, J. H.; de Renstrom, P. A. Bruckman; Bruncko, D.; Bruneliere, R.; Bruni, A.; Bruni, G.; Brunt, BH; Bruschi, M.; Bruscino, N.; Bryant, P.; Bryngemark, L.; Buanes, T.; Buat, Q.; Buchholz, P.; Buckley, A. G.; Budagov, I. A.; Buehrer, F.; Bugge, M. K.; Bulekov, O.; Bullock, D.; Burckhart, H.; Burdin, S.; Burgard, C. D.; Burghgrave, B.; Burka, K.; Burke, S.; Burmeister, I.; Busato, E.; Büscher, D.; Büscher, V.; Bussey, P.; Butler, J. M.; Butt, A. I.; Buttar, C. M.; Butterworth, J. M.; Butti, P.; Buttinger, W.; Buzatu, A.; Buzykaev, A. R.; Urbán, S. Cabrera; Caforio, D.; Cairo, V. M.; Cakir, O.; Calace, N.; Calafiura, P.; Calandri, A.; Calderini, G.; Calfayan, P.; Caloba, L. P.; Calvet, D.; Calvet, S.; Calvet, T. P.; Toro, R. Camacho; Camarda, S.; Camarri, P.; Cameron, D.; Armadans, R. Caminal; Camincher, C.; Campana, S.; Campanelli, M.; Campoverde, A.; Canale, V.; Canepa, A.; Bret, M. Cano; Cantero, J.; Cantrill, R.; Cao, T.; Garrido, M. D. M. Capeans; Caprini, I.; Caprini, M.; Capua, M.; Caputo, R.; Carbone, R. M.; Cardarelli, R.; Cardillo, F.; Carli, I.; Carli, T.; Carlino, G.; Carminati, L.; Caron, S.; Carquin, E.; Carrillo-Montoya, G. D.; Carter, J. R.; Carvalho, J.; Casadei, D.; Casado, M. P.; Casolino, M.; Casper, D. W.; Castaneda-Miranda, E.; Castelli, A.; Gimenez, V. Castillo; Castro, N. F.; Catinaccio, A.; Catmore, J. R.; Cattai, A.; Caudron, J.; Cavaliere, V.; Cavallaro, E.; Cavalli, D.; Cavalli-Sforza, M.; Cavasinni, V.; Ceradini, F.; Alberich, L. Cerda; Cerio, B. C.; Cerqueira, A. S.; Cerri, A.; Cerrito, L.; Cerutti, F.; Cerv, M.; Cervelli, A.; Cetin, S. A.; Chafaq, A.; Chakraborty, D.; Chan, S. K.; Chan, Y. L.; Chang, P.; Chapman, J. D.; Charlton, D. G.; Chatterjee, A.; Chau, C. C.; Barajas, C. A. Chavez; Che, S.; Cheatham, S.; Chegwidden, A.; Chekanov, S.; Chekulaev, S. V.; Chelkov, G. A.; Chelstowska, M. A.; Chen, C.; Chen, H.; Chen, K.; Chen, S.; Chen, S.; Chen, X.; Chen, Y.; Cheng, H. C.; Cheng, H. J.; Cheng, Y.; Cheplakov, A.; Cheremushkina, E.; Moursli, R. Cherkaoui El; Chernyatin, V.; Cheu, E.; Chevalier, L.; Chiarella, V.; Chiarelli, G.; Chiodini, G.; Chisholm, A. S.; Chitan, A.; Chizhov, M. V.; Choi, K.; Chomont, A. R.; Chouridou, S.; Chow, B. K. B.; Christodoulou, V.; Chromek-Burckhart, D.; Chudoba, J.; Chuinard, A. J.; Chwastowski, J. J.; Chytka, L.; Ciapetti, G.; Ciftci, A. K.; Cinca, D.; Cindro, V.; Cioara, I. A.; Ciocio, A.; Cirotto, F.; Citron, Z. H.; Ciubancan, M.; Clark, A.; Clark, B. L.; Clark, M. R.; Clark, P. J.; Clarke, R. N.; Clement, C.; Coadou, Y.; Cobal, M.; Coccaro, A.; Cochran, J.; Coffey, L.; Colasurdo, L.; Cole, B.; Cole, S.; Colijn, A. P.; Collot, J.; Colombo, T.; Compostella, G.; Muiño, P. Conde; Coniavitis, E.; Connell, S. H.; Connelly, I. A.; Consorti, V.; Constantinescu, S.; Conta, C.; Conti, G.; Conventi, F.; Cooke, M.; Cooper, B. D.; Cooper-Sarkar, A. M.; Cornelissen, T.; Corradi, M.; Corriveau, F.; Corso-Radu, A.; Cortes-Gonzalez, A.; Cortiana, G.; Costa, G.; Costa, M. J.; Costanzo, D.; Cottin, G.; Cowan, G.; Cox, B. E.; Cranmer, K.; Crawley, S. J.; Cree, G.; Crépé-Renaudin, S.; Crescioli, F.; Cribbs, W. A.; Ortuzar, M. Crispin; Cristinziani, M.; Croft, V.; Crosetti, G.; Donszelmann, T. Cuhadar; Cummings, J.; Curatolo, M.; Cúth, J.; Cuthbert, C.; Czirr, H.; Czodrowski, P.; D'Auria, S.; D'Onofrio, M.; De Sousa, M. J. Da Cunha Sargedas; Via, C. Da; Dabrowski, W.; Dai, T.; Dale, O.; Dallaire, F.; Dallapiccola, C.; Dam, M.; Dandoy, J. R.; Dang, N. P.; Daniells, A. C.; Dann, N. S.; Danninger, M.; Hoffmann, M. Dano; Dao, V.; Darbo, G.; Darmora, S.; Dassoulas, J.; Dattagupta, A.; Davey, W.; David, C.; Davidek, T.; Davies, M.; Davison, P.; Davygora, Y.; Dawe, E.; Dawson, I.; Daya-Ishmukhametova, R. K.; De, K.; de Asmundis, R.; De Benedetti, A.; De Castro, S.; De Cecco, S.; De Groot, N.; de Jong, P.; De la Torre, H.; De Lorenzi, F.; De Pedis, D.; De Salvo, A.; De Sanctis, U.; De Santo, A.; De Regie, J. B. De Vivie; Dearnaley, W. J.; Debbe, R.; Debenedetti, C.; Dedovich, D. V.; Deigaard, I.; Del Peso, J.; Del Prete, T.; Delgove, D.; Deliot, F.; Delitzsch, C. M.; Deliyergiyev, M.; Dell'Acqua, A.; Dell'Asta, L.; Dell'Orso, M.; Della Pietra, M.; della Volpe, D.; Delmastro, M.; Delsart, P. A.; Deluca, C.; DeMarco, D. A.; Demers, S.; Demichev, M.; Demilly, A.; Denisov, S. P.; Denysiuk, D.; Derendarz, D.; Derkaoui, J. E.; Derue, F.; Dervan, P.; Desch, K.; Deterre, C.; Dette, K.; Deviveiros, P. O.; Dewhurst, A.; Dhaliwal, S.; Di Ciaccio, A.; Di Ciaccio, L.; Di Clemente, W. K.; Di Donato, C.; Di Girolamo, A.; Di Girolamo, B.; Di Micco, B.; Di Nardo, R.; Di Simone, A.; Di Sipio, R.; Di Valentino, D.; Diaconu, C.; Diamond, M.; Dias, F. A.; Diaz, M. A.; Diehl, E. B.; Dietrich, J.; Diglio, S.; Dimitrievska, A.; Dingfelder, J.; Dita, P.; Dita, S.; Dittus, F.; Djama, F.; Djobava, T.; Djuvsland, J. I.; do Vale, M. A. B.; Dobos, D.; Dobre, M.; Doglioni, C.; Dohmae, T.; Dolejsi, J.; Dolezal, Z.; Dolgoshein, B. A.; Donadelli, M.; Donati, S.; Dondero, P.; Donini, J.; Dopke, J.; Doria, A.; Dova, M. T.; Doyle, A. T.; Drechsler, E.; Dris, M.; Du, Y.; Duarte-Campderros, J.; Duchovni, E.; Duckeck, G.; Ducu, O. A.; Duda, D.; Dudarev, A.; Duflot, L.; Duguid, L.; Dührssen, M.; Dunford, M.; Yildiz, H. Duran; Düren, M.; Durglishvili, A.; Duschinger, D.; Dutta, B.; Dyndal, M.; Eckardt, C.; Ecker, K. M.; Edgar, R. C.; Edson, W.; Edwards, N. C.; Eifert, T.; Eigen, G.; Einsweiler, K.; Ekelof, T.; Kacimi, M. El; Ellajosyula, V.; Ellert, M.; Elles, S.; Ellinghaus, F.; Elliot, A. A.; Ellis, N.; Elmsheuser, J.; Elsing, M.; Emeliyanov, D.; Enari, Y.; Endner, O. C.; Endo, M.; Ennis, J. S.; Erdmann, J.; Ereditato, A.; Ernis, G.; Ernst, J.; Ernst, M.; Errede, S.; Ertel, E.; Escalier, M.; Esch, H.; Escobar, C.; Esposito, B.; Etienvre, A. I.; Etzion, E.; Evans, H.; Ezhilov, A.; Fabbri, F.; Fabbri, L.; Facini, G.; Fakhrutdinov, R. M.; Falciano, S.; Falla, R. J.; Faltova, J.; Fang, Y.; Fanti, M.; Farbin, A.; Farilla, A.; Farina, C.; Farooque, T.; Farrell, S.; Farrington, S. M.; Farthouat, P.; Fassi, F.; Fassnacht, P.; Fassouliotis, D.; Giannelli, M. Faucci; Favareto, A.; Fawcett, W. J.; Fayard, L.; Fedin, O. L.; Fedorko, W.; Feigl, S.; Feligioni, L.; Feng, C.; Feng, E. J.; Feng, H.; Fenyuk, A. B.; Feremenga, L.; Martinez, P. Fernandez; Perez, S. Fernandez; Ferrando, J.; Ferrari, A.; Ferrari, P.; Ferrari, R.; de Lima, D. E. Ferreira; Ferrer, A.; Ferrere, D.; Ferretti, C.; Parodi, A. Ferretto; Fiedler, F.; Filipčič, A.; Filipuzzi, M.; Filthaut, F.; Fincke-Keeler, M.; Finelli, K. D.; Fiolhais, M. C. N.; Fiorini, L.; Firan, A.; Fischer, A.; Fischer, C.; Fischer, J.; Fisher, W. C.; Flaschel, N.; Fleck, I.; Fleischmann, P.; Fletcher, G. T.; Fletcher, G.; Fletcher, R. R. M.; Flick, T.; Floderus, A.; Castillo, L. R. Flores; Flowerdew, M. J.; Forcolin, G. T.; Formica, A.; Forti, A.; Foster, A. G.; Fournier, D.; Fox, H.; Fracchia, S.; Francavilla, P.; Franchini, M.; Francis, D.; Franconi, L.; Franklin, M.; Frate, M.; Fraternali, M.; Freeborn, D.; Fressard-Batraneanu, S. M.; Friedrich, F.; Froidevaux, D.; Frost, J. A.; Fukunaga, C.; Torregrosa, E. Fullana; Fusayasu, T.; Fuster, J.; Gabaldon, C.; Gabizon, O.; Gabrielli, A.; Gabrielli, A.; Gach, G. P.; Gadatsch, S.; Gadomski, S.; Gagliardi, G.; Gagnon, L. G.; Gagnon, P.; Galea, C.; Galhardo, B.; Gallas, E. J.; Gallop, B. J.; Gallus, P.; Galster, G.; Gan, K. K.; Gao, J.; Gao, Y.; Gao, Y. S.; Walls, F. M. Garay; García, C.; Navarro, J. E. García; Garcia-Sciveres, M.; Gardner, R. W.; Garelli, N.; Garonne, V.; Bravo, A. Gascon; Gatti, C.; Gaudiello, A.; Gaudio, G.; Gaur, B.; Gauthier, L.; Gavrilenko, I. L.; Gay, C.; Gaycken, G.; Gazis, E. N.; Gecse, Z.; Gee, C. N. P.; Geich-Gimbel, Ch.; Geisler, M. P.; Gemme, C.; Genest, M. H.; Geng, C.; Gentile, S.; George, S.; Gerbaudo, D.; Gershon, A.; Ghasemi, S.; Ghazlane, H.; Ghneimat, M.; Giacobbe, B.; Giagu, S.; Giannetti, P.; Gibbard, B.; Gibson, S. M.; Gignac, M.; Gilchriese, M.; Gillam, T. P. S.; Gillberg, D.; Gilles, G.; Gingrich, D. M.; Giokaris, N.; Giordani, M. P.; Giorgi, F. M.; Giorgi, F. M.; Giraud, P. F.; Giromini, P.; Giugni, D.; Giuli, F.; Giuliani, C.; Giulini, M.; Gjelsten, B. K.; Gkaitatzis, S.; Gkialas, I.; Gkougkousis, E. L.; Gladilin, L. K.; Glasman, C.; Glatzer, J.; Glaysher, P. C. F.; Glazov, A.; Goblirsch-Kolb, M.; Godlewski, J.; Goldfarb, S.; Golling, T.; Golubkov, D.; Gomes, A.; Gonçalo, R.; Costa, J. Goncalves Pinto Firmino Da; Gonella, L.; Gongadze, A.; de la Hoz, S. González; Parra, G. Gonzalez; Gonzalez-Sevilla, S.; Goossens, L.; Gorbounov, P. A.; Gordon, H. A.; Gorelov, I.; Gorini, B.; Gorini, E.; Gorišek, A.; Gornicki, E.; Goshaw, A. T.; Gössling, C.; Gostkin, M. I.; Goudet, C. R.; Goujdami, D.; Goussiou, A. G.; Govender, N.; Gozani, E.; Graber, L.; Grabowska-Bold, I.; Gradin, P. O. J.; Grafström, P.; Gramling, J.; Gramstad, E.; Grancagnolo, S.; Gratchev, V.; Gray, H. M.; Graziani, E.; Greenwood, Z. D.; Grefe, C.; Gregersen, K.; Gregor, I. M.; Grenier, P.; Grevtsov, K.; Griffiths, J.; Grillo, A. A.; Grimm, K.; Grinstein, S.; Gris, Ph.; Grivaz, J.-F.; Groh, S.; Grohs, J. P.; Gross, E.; Grosse-Knetter, J.; Grossi, G. C.; Grout, Z. J.; Guan, L.; Guan, W.; Guenther, J.; Guescini, F.; Guest, D.; Gueta, O.; Guido, E.; Guillemin, T.; Guindon, S.; Gul, U.; Gumpert, C.; Guo, J.; Guo, Y.; Gupta, S.; Gustavino, G.; Gutierrez, P.; Ortiz, N. G. Gutierrez; Gutschow, C.; Guyot, C.; Gwenlan, C.; Gwilliam, C. B.; Haas, A.; Haber, C.; Hadavand, H. K.; Haddad, N.; Hadef, A.; Haefner, P.; Hageböck, S.; Hajduk, Z.; Hakobyan, H.; Haleem, M.; Haley, J.; Hall, D.; Halladjian, G.; Hallewell, G. D.; Hamacher, K.; Hamal, P.; Hamano, K.; Hamilton, A.; Hamity, G. N.; Hamnett, P. G.; Han, L.; Hanagaki, K.; Hanawa, K.; Hance, M.; Haney, B.; Hanke, P.; Hanna, R.; Hansen, J. B.; Hansen, J. D.; Hansen, M. C.; Hansen, P. H.; Hara, K.; Hard, A. S.; Harenberg, T.; Hariri, F.; Harkusha, S.; Harrington, R. D.; Harrison, P. F.; Hartjes, F.; Hasegawa, M.; Hasegawa, Y.; Hasib, A.; Hassani, S.; Haug, S.; Hauser, R.; Hauswald, L.; Havranek, M.; Hawkes, C. M.; Hawkings, R. J.; Hawkins, A. D.; Hayden, D.; Hays, C. P.; Hays, J. M.; Hayward, H. S.; Haywood, S. J.; Head, S. J.; Heck, T.; Hedberg, V.; Heelan, L.; Heim, S.; Heim, T.; Heinemann, B.; Heinrich, J. J.; Heinrich, L.; Heinz, C.; Hejbal, J.; Helary, L.; Hellman, S.; Helsens, C.; Henderson, J.; Henderson, R. C. W.; Heng, Y.; Henkelmann, S.; Correia, A. M. Henriques; Henrot-Versille, S.; Herbert, G. H.; Jiménez, Y. Hernández; Herten, G.; Hertenberger, R.; Hervas, L.; Hesketh, G. G.; Hessey, N. P.; Hetherly, J. W.; Hickling, R.; Higón-Rodriguez, E.; Hill, E.; Hill, J. C.; Hiller, K. H.; Hillier, S. J.; Hinchliffe, I.; Hines, E.; Hinman, R. R.; Hirose, M.; Hirschbuehl, D.; Hobbs, J.; Hod, N.; Hodgkinson, M. C.; Hodgson, P.; Hoecker, A.; Hoeferkamp, M. R.; Hoenig, F.; Hohlfeld, M.; Hohn, D.; Holmes, T. R.; Homann, M.; Hong, T. M.; Hooberman, B. H.; Hopkins, W. H.; Horii, Y.; Horton, A. J.; Hostachy, J.-Y.; Hou, S.; Hoummada, A.; Howard, J.; Howarth, J.; Hrabovsky, M.; Hristova, I.; Hrivnac, J.; Hryn'ova, T.; Hrynevich, A.; Hsu, C.; Hsu, P. J.; Hsu, S.-C.; Hu, D.; Hu, Q.; Huang, Y.; Hubacek, Z.; Hubaut, F.; Huegging, F.; Huffman, T. B.; Hughes, E. W.; Hughes, G.; Huhtinen, M.; Hülsing, T. A.; Huseynov, N.; Huston, J.; Huth, J.; Iacobucci, G.; Iakovidis, G.; Ibragimov, I.; Iconomidou-Fayard, L.; Ideal, E.; Idrissi, Z.; Iengo, P.; Igonkina, O.; Iizawa, T.; Ikegami, Y.; Ikeno, M.; Ilchenko, Y.; Iliadis, D.; Ilic, N.; Ince, T.; Introzzi, G.; Ioannou, P.; Iodice, M.; Iordanidou, K.; Ippolito, V.; Quiles, A. Irles; Isaksson, C.; Ishino, M.; Ishitsuka, M.; Ishmukhametov, R.; Issever, C.; Istin, S.; Ito, F.; Ponce, J. M. Iturbe; Iuppa, R.; Ivarsson, J.; Iwanski, W.; Iwasaki, H.; Izen, J. M.; Izzo, V.; Jabbar, S.; Jackson, B.; Jackson, M.; Jackson, P.; Jain, V.; Jakobi, K. B.; Jakobs, K.; Jakobsen, S.; Jakoubek, T.; Jamin, D. O.; Jana, D. K.; Jansen, E.; Jansky, R.; Janssen, J.; Janus, M.; Jarlskog, G.; Javadov, N.; Javůrek, T.; Jeanneau, F.; Jeanty, L.; Jejelava, J.; Jeng, G.-Y.; Jennens, D.; Jenni, P.; Jentzsch, J.; Jeske, C.; Jézéquel, S.; Ji, H.; Jia, J.; Jiang, H.; Jiang, Y.; Jiggins, S.; Pena, J. Jimenez; Jin, S.; Jinaru, A.; Jinnouchi, O.; Johansson, P.; Johns, K. A.; Johnson, W. J.; Jon-And, K.; Jones, G.; Jones, R. W. L.; Jones, S.; Jones, T. J.; Jongmanns, J.; Jorge, P. M.; Jovicevic, J.; Ju, X.; Rozas, A. Juste; Köhler, M. K.; Kaczmarska, A.; Kado, M.; Kagan, H.; Kagan, M.; Kahn, S. J.; Kajomovitz, E.; Kalderon, C. W.; Kaluza, A.; Kama, S.; Kamenshchikov, A.; Kanaya, N.; Kaneti, S.; Kantserov, V. A.; Kanzaki, J.; Kaplan, B.; Kaplan, L. S.; Kapliy, A.; Kar, D.; Karakostas, K.; Karamaoun, A.; Karastathis, N.; Kareem, M. J.; Karentzos, E.; Karnevskiy, M.; Karpov, S. N.; Karpova, Z. M.; Karthik, K.; Kartvelishvili, V.; Karyukhin, A. N.; Kasahara, K.; Kashif, L.; Kass, R. D.; Kastanas, A.; Kataoka, Y.; Kato, C.; Katre, A.; Katzy, J.; Kawagoe, K.; Kawamoto, T.; Kawamura, G.; Kazama, S.; Kazanin, V. F.; Keeler, R.; Kehoe, R.; Keller, J. S.; Kempster, J. J.; Kentaro, K.; Keoshkerian, H.; Kepka, O.; Kerševan, B. P.; Kersten, S.; Keyes, R. A.; Khalil-zada, F.; Khandanyan, H.; Khanov, A.; Kharlamov, A. G.; Khoo, T. J.; Khovanskiy, V.; Khramov, E.; Khubua, J.; Kido, S.; Kim, H. Y.; Kim, S. H.; Kim, Y. K.; Kimura, N.; Kind, O. M.; King, B. T.; King, M.; King, S. B.; Kirk, J.; Kiryunin, A. E.; Kishimoto, T.; Kisielewska, D.; Kiss, F.; Kiuchi, K.; Kivernyk, O.; Kladiva, E.; Klein, M. H.; Klein, M.; Klein, U.; Kleinknecht, K.; Klimek, P.; Klimentov, A.; Klingenberg, R.; Klinger, J. A.; Klioutchnikova, T.; Kluge, E.-E.; Kluit, P.; Kluth, S.; Knapik, J.; Kneringer, E.; Knoops, E. B. F. G.; Knue, A.; Kobayashi, A.; Kobayashi, D.; Kobayashi, T.; Kobel, M.; Kocian, M.; Kodys, P.; Koffas, T.; Koffeman, E.; Kogan, L. A.; Koi, T.; Kolanoski, H.; Kolb, M.; Koletsou, I.; Komar, A. A.; Komori, Y.; Kondo, T.; Kondrashova, N.; Köneke, K.; König, A. C.; Kono, T.; Konoplich, R.; Konstantinidis, N.; Kopeliansky, R.; Koperny, S.; Köpke, L.; Kopp, A. K.; Korcyl, K.; Kordas, K.; Korn, A.; Korol, A. A.; Korolkov, I.; Korolkova, E. V.; Kortner, O.; Kortner, S.; Kosek, T.; Kostyukhin, V. V.; Kotwal, A.; Kourkoumeli-Charalampidi, A.; Kourkoumelis, C.; Kouskoura, V.; Koutsman, A.; Kowalewska, A. B.; Kowalewski, R.; Kowalski, T. Z.; Kozanecki, W.; Kozhin, A. S.; Kramarenko, V. A.; Kramberger, G.; Krasnopevtsev, D.; Krasny, M. W.; Krasznahorkay, A.; Kraus, J. K.; Kravchenko, A.; Kretz, M.; Kretzschmar, J.; Kreutzfeldt, K.; Krieger, P.; Krizka, K.; Kroeninger, K.; Kroha, H.; Kroll, J.; Kroseberg, J.; Krstic, J.; Kruchonak, U.; Krüger, H.; Krumnack, N.; Kruse, A.; Kruse, M. C.; Kruskal, M.; Kubota, T.; Kucuk, H.; Kuday, S.; Kuechler, J. T.; Kuehn, S.; Kugel, A.; Kuger, F.; Kuhl, A.; Kuhl, T.; Kukhtin, V.; Kukla, R.; Kulchitsky, Y.; Kuleshov, S.; Kuna, M.; Kunigo, T.; Kupco, A.; Kurashige, H.; Kurochkin, Y. A.; Kus, V.; Kuwertz, E. S.; Kuze, M.; Kvita, J.; Kwan, T.; Kyriazopoulos, D.; Rosa, A. La; Navarro, J. L. La Rosa; Rotonda, L. La; Lacasta, C.; Lacava, F.; Lacey, J.; Lacker, H.; Lacour, D.; Lacuesta, V. R.; Ladygin, E.; Lafaye, R.; Laforge, B.; Lagouri, T.; Lai, S.; Lammers, S.; Lampl, W.; Lançon, E.; Landgraf, U.; Landon, M. P. J.; Lang, V. S.; Lange, J. C.; Lankford, A. J.; Lanni, F.; Lantzsch, K.; Lanza, A.; Laplace, S.; Lapoire, C.; Laporte, J. F.; Lari, T.; Manghi, F. Lasagni; Lassnig, M.; Laurelli, P.; Lavrijsen, W.; Law, A. T.; Laycock, P.; Lazovich, T.; Lazzaroni, M.; Dortz, O. Le; Guirriec, E. Le; Menedeu, E. Le; Quilleuc, E. P. Le; LeBlanc, M.; LeCompte, T.; Ledroit-Guillon, F.; Lee, C. A.; Lee, S. C.; Lee, L.; Lefebvre, G.; Lefebvre, M.; Legger, F.; Leggett, C.; Lehan, A.; Miotto, G. Lehmann; Lei, X.; Leight, W. A.; Leisos, A.; Leister, A. G.; Leite, M. A. L.; Leitner, R.; Lellouch, D.; Lemmer, B.; Leney, K. J. C.; Lenz, T.; Lenzi, B.; Leone, R.; Leone, S.; Leonidopoulos, C.; Leontsinis, S.; Lerner, G.; Leroy, C.; Lesage, A. A. J.; Lester, C. G.; Levchenko, M.; Levêque, J.; Levin, D.; Levinson, L. J.; Levy, M.; Leyko, A. M.; Leyton, M.; Li, B.; Li, H.; Li, H. L.; Li, L.; Li, L.; Li, Q.; Li, S.; Li, X.; Li, Y.; Liang, Z.; Liao, H.; Liberti, B.; Liblong, A.; Lichard, P.; Lie, K.; Liebal, J.; Liebig, W.; Limbach, C.; Limosani, A.; Lin, S. C.; Lin, T. H.; Lindquist, B. E.; Lipeles, E.; Lipniacka, A.; Lisovyi, M.; Liss, T. M.; Lissauer, D.; Lister, A.; Litke, A. M.; Liu, B.; Liu, D.; Liu, H.; Liu, H.; Liu, J.; Liu, J. B.; Liu, K.; Liu, L.; Liu, M.; Liu, M.; Liu, Y. L.; Liu, Y.; Livan, M.; Lleres, A.; Merino, J. Llorente; Lloyd, S. L.; Sterzo, F. Lo; Lobodzinska, E.; Loch, P.; Lockman, W. S.; Loebinger, F. K.; Loevschall-Jensen, A. E.; Loew, K. M.; Loginov, A.; Lohse, T.; Lohwasser, K.; Lokajicek, M.; Long, B. A.; Long, J. D.; Long, R. E.; Longo, L.; Looper, K. A.; Lopes, L.; Mateos, D. Lopez; Paredes, B. Lopez; Paz, I. Lopez; Solis, A. Lopez; Lorenz, J.; Martinez, N. Lorenzo; Losada, M.; Lösel, P. J.; Lou, X.; Lounis, A.; Love, J.; Love, P. A.; Lu, H.; Lu, N.; Lubatti, H. J.; Luci, C.; Lucotte, A.; Luedtke, C.; Luehring, F.; Lukas, W.; Luminari, L.; Lundberg, O.; Lund-Jensen, B.; Lynn, D.; Lysak, R.; Lytken, E.; Lyubushkin, V.; Ma, H.; Ma, L. L.; Ma, Y.; Maccarrone, G.; Macchiolo, A.; Macdonald, C. M.; Maček, B.; Miguens, J. Machado; Madaffari, D.; Madar, R.; Maddocks, H. J.; Mader, W. F.; Madsen, A.; Maeda, J.; Maeland, S.; Maeno, T.; Maevskiy, A.; Magradze, E.; Mahlstedt, J.; Maiani, C.; Maidantchik, C.; Maier, A. A.; Maier, T.; Maio, A.; Majewski, S.; Makida, Y.; Makovec, N.; Malaescu, B.; Malecki, Pa.; Maleev, V. P.; Malek, F.; Mallik, U.; Malon, D.; Malone, C.; Maltezos, S.; Malyukov, S.; Mamuzic, J.; Mancini, G.; Mandelli, B.; Mandelli, L.; Mandić, I.; Maneira, J.; Filho, L. Manhaes de Andrade; Ramos, J. Manjarres; Mann, A.; Mansoulie, B.; Mantifel, R.; Mantoani, M.; Manzoni, S.; Mapelli, L.; Marceca, G.; March, L.; Marchiori, G.; Marcisovsky, M.; Marjanovic, M.; Marley, D. E.; Marroquim, F.; Marsden, S. P.; Marshall, Z.; Marti, L. F.; Marti-Garcia, S.; Martin, B.; Martin, T. A.; Martin, V. J.; Latour, B. Martin dit; Martinez, M.; Martin-Haugh, S.; Martoiu, V. S.; Martyniuk, A. C.; Marx, M.; Marzano, F.; Marzin, A.; Masetti, L.; Mashimo, T.; Mashinistov, R.; Masik, J.; Maslennikov, A. L.; Massa, I.; Massa, L.; Mastrandrea, P.; Mastroberardino, A.; Masubuchi, T.; Mättig, P.; Mattmann, J.; Maurer, J.; Maxfield, S. J.; Maximov, D. A.; Mazini, R.; Mazza, S. M.; Fadden, N. C. Mc; Goldrick, G. Mc; Kee, S. P. Mc; McCarn, A.; McCarthy, R. L.; McCarthy, T. G.; McClymont, L. I.; McFarlane, K. W.; Mcfayden, J. A.; Mchedlidze, G.; McMahon, S. J.; McPherson, R. A.; Medinnis, M.; Meehan, S.; Mehlhase, S.; Mehta, A.; Meier, K.; Meineck, C.; Meirose, B.; Garcia, B. R. Mellado; Meloni, F.; Mengarelli, A.; Menke, S.; Meoni, E.; Mercurio, K. M.; Mergelmeyer, S.; Mermod, P.; Merola, L.; Meroni, C.; Merritt, F. S.; Messina, A.; Metcalfe, J.; Mete, A. S.; Meyer, C.; Meyer, C.; Meyer, J.-P.; Meyer, J.; Theenhausen, H. Meyer Zu; Middleton, R. P.; Miglioranzi, S.; Mijović, L.; Mikenberg, G.; Mikestikova, M.; Mikuž, M.; Milesi, M.; Milic, A.; Miller, D. W.; Mills, C.; Milov, A.; Milstead, D. A.; Minaenko, A. A.; Minami, Y.; Minashvili, I. A.; Mincer, A. I.; Mindur, B.; Mineev, M.; Ming, Y.; Mir, L. M.; Mistry, K. P.; Mitani, T.; Mitrevski, J.; Mitsou, V. A.; Miucci, A.; Miyagawa, P. S.; Mjörnmark, J. U.; Moa, T.; Mochizuki, K.; Mohapatra, S.; Mohr, W.; Molander, S.; Moles-Valls, R.; Monden, R.; Mondragon, M. C.; Mönig, K.; Monk, J.; Monnier, E.; Montalbano, A.; Berlingen, J. Montejo; Monticelli, F.; Monzani, S.; Moore, R. W.; Morange, N.; Moreno, D.; Llácer, M. Moreno; Morettini, P.; Mori, D.; Mori, T.; Morii, M.; Morinaga, M.; Morisbak, V.; Moritz, S.; Morley, A. K.; Mornacchi, G.; Morris, J. D.; Mortensen, S. S.; Morvaj, L.; Mosidze, M.; Moss, J.; Motohashi, K.; Mount, R.; Mountricha, E.; Mouraviev, S. V.; Moyse, E. J. W.; Muanza, S.; Mudd, R. D.; Mueller, F.; Mueller, J.; Mueller, R. S. P.; Mueller, T.; Muenstermann, D.; Mullen, P.; Mullier, G. A.; Sanchez, F. J. Munoz; Quijada, J. A. Murillo; Murray, W. J.; Musheghyan, H.; Muškinja, M.; Myagkov, A. G.; Myska, M.; Nachman, B. P.; Nackenhorst, O.; Nadal, J.; Nagai, K.; Nagai, R.; Nagano, K.; Nagasaka, Y.; Nagata, K.; Nagel, M.; Nagy, E.; Nairz, A. M.; Nakahama, Y.; Nakamura, K.; Nakamura, T.; Nakano, I.; Namasivayam, H.; Garcia, R. F. Naranjo; Narayan, R.; Villar, D. I. Narrias; Naryshkin, I.; Naumann, T.; Navarro, G.; Nayyar, R.; Neal, H. A.; Nechaeva, P. Yu.; Neep, T. J.; Nef, P. D.; Negri, A.; Negrini, M.; Nektarijevic, S.; Nellist, C.; Nelson, A.; Nemecek, S.; Nemethy, P.; Nepomuceno, A. A.; Nessi, M.; Neubauer, M. S.; Neumann, M.; Neves, R. M.; Nevski, P.; Newman, P. R.; Nguyen, D. H.; Nickerson, R. B.; Nicolaidou, R.; Nicquevert, B.; Nielsen, J.; Nikiforov, A.; Nikolaenko, V.; Nikolic-Audit, I.; Nikolopoulos, K.; Nilsen, J. K.; Nilsson, P.; Ninomiya, Y.; Nisati, A.; Nisius, R.; Nobe, T.; Nodulman, L.; Nomachi, M.; Nomidis, I.; Nooney, T.; Norberg, S.; Nordberg, M.; Norjoharuddeen, N.; Novgorodova, O.; Nowak, S.; Nozaki, M.; Nozka, L.; Ntekas, K.; Nurse, E.; Nuti, F.; O'grady, F.; O'Neil, D. C.; O'Rourke, A. A.; O'Shea, V.; Oakham, F. G.; Oberlack, H.; Obermann, T.; Ocariz, J.; Ochi, A.; Ochoa, I.; Ochoa-Ricoux, J. P.; Oda, S.; Odaka, S.; Ogren, H.; Oh, A.; Oh, S. H.; Ohm, C. C.; Ohman, H.; Oide, H.; Okawa, H.; Okumura, Y.; Okuyama, T.; Olariu, A.; Seabra, L. F. Oleiro; Pino, S. A. Olivares; Damazio, D. Oliveira; Olszewski, A.; Olszowska, J.; Onofre, A.; Onogi, K.; Onyisi, P. U. E.; Oram, C. J.; Oreglia, M. J.; Oren, Y.; Orestano, D.; Orlando, N.; Orr, R. S.; Osculati, B.; Ospanov, R.; Garzon, G. Otero y.; Otono, H.; Ouchrif, M.; Ould-Saada, F.; Ouraou, A.; Oussoren, K. P.; Ouyang, Q.; Ovcharova, A.; Owen, M.; Owen, R. E.; Ozcan, V. E.; Ozturk, N.; Pachal, K.; Pages, A. Pacheco; Aranda, C. Padilla; Pagáčová, M.; Griso, S. Pagan; Paige, F.; Pais, P.; Pajchel, K.; Palacino, G.; Palestini, S.; Palka, M.; Pallin, D.; Palma, A.; Panagiotopoulou, E. St.; Pandini, C. E.; Vazquez, J. G. Panduro; Pani, P.; Panitkin, S.; Pantea, D.; Paolozzi, L.; Papadopoulou, Th. D.; Papageorgiou, K.; Paramonov, A.; Hernandez, D. Paredes; Parker, A. J.; Parker, M. A.; Parker, K. A.; Parodi, F.; Parsons, J. A.; Parzefall, U.; Pascuzzi, V. R.; Pasqualucci, E.; Passaggio, S.; Pastore, F.; Pastore, Fr.; Pásztor, G.; Pataraia, S.; Patel, N. D.; Pater, J. R.; Pauly, T.; Pearce, J.; Pearson, B.; Pedersen, L. E.; Pedersen, M.; Lopez, S. Pedraza; Pedro, R.; Peleganchuk, S. V.; Pelikan, D.; Penc, O.; Peng, C.; Peng, H.; Penwell, J.; Peralva, B. S.; Perego, M. M.; Perepelitsa, D. V.; Codina, E. Perez; Perini, L.; Pernegger, H.; Perrella, S.; Peschke, R.; Peshekhonov, V. D.; Peters, K.; Peters, R. F. Y.; Petersen, B. A.; Petersen, T. C.; Petit, E.; Petridis, A.; Petridou, C.; Petroff, P.; Petrolo, E.; Petrov, M.; Petrucci, F.; Pettersson, N. E.; Peyaud, A.; Pezoa, R.; Phillips, P. W.; Piacquadio, G.; Pianori, E.; Picazio, A.; Piccaro, E.; Piccinini, M.; Pickering, M. A.; Piegaia, R.; Pilcher, J. E.; Pilkington, A. D.; Pin, A. W. J.; Pina, J.; Pinamonti, M.; Pinfold, J. L.; Pingel, A.; Pires, S.; Pirumov, H.; Pitt, M.; Plazak, L.; Pleier, M.-A.; Pleskot, V.; Plotnikova, E.; Plucinski, P.; Pluth, D.; Poettgen, R.; Poggioli, L.; Pohl, D.; Polesello, G.; Poley, A.; Policicchio, A.; Polifka, R.; Polini, A.; Pollard, C. S.; Polychronakos, V.; Pommès, K.; Pontecorvo, L.; Pope, B. G.; Popeneciu, G. A.; Popovic, D. S.; Poppleton, A.; Pospisil, S.; Potamianos, K.; Potrap, I. N.; Potter, C. J.; Potter, C. T.; Poulard, G.; Poveda, J.; Pozdnyakov, V.; Astigarraga, M. E. Pozo; Pralavorio, P.; Pranko, A.; Prell, S.; Price, D.; Price, L. E.; Primavera, M.; Prince, S.; Proissl, M.; Prokofiev, K.; Prokoshin, F.; Protopopescu, S.; Proudfoot, J.; Przybycien, M.; Puddu, D.; Puldon, D.; Purohit, M.; Puzo, P.; Qian, J.; Qin, G.; Qin, Y.; Quadt, A.; Quayle, W. B.; Queitsch-Maitland, M.; Quilty, D.; Raddum, S.; Radeka, V.; Radescu, V.; Radhakrishnan, S. K.; Radloff, P.; Rados, P.; Ragusa, F.; Rahal, G.; Raine, J. A.; Rajagopalan, S.; Rammensee, M.; Rangel-Smith, C.; Ratti, M. G.; Rauscher, F.; Rave, S.; Ravenscroft, T.; Raymond, M.; Read, A. L.; Readioff, N. P.; Rebuzzi, D. M.; Redelbach, A.; Redlinger, G.; Reece, R.; Reeves, K.; Rehnisch, L.; Reichert, J.; Reisin, H.; Rembser, C.; Ren, H.; Rescigno, M.; Resconi, S.; Rezanova, O. L.; Reznicek, P.; Rezvani, R.; Richter, R.; Richter, S.; Richter-Was, E.; Ricken, O.; Ridel, M.; Rieck, P.; Riegel, C. J.; Rieger, J.; Rifki, O.; Rijssenbeek, M.; Rimoldi, A.; Rinaldi, L.; Ristić, B.; Ritsch, E.; Riu, I.; Rizatdinova, F.; Rizvi, E.; Rizzi, C.; Robertson, S. H.; Robichaud-Veronneau, A.; Robinson, D.; Robinson, J. E. M.; Robson, A.; Roda, C.; Rodina, Y.; Perez, A. Rodriguez; Rodriguez, D. Rodriguez; Roe, S.; Rogan, C. S.; Røhne, O.; Romaniouk, A.; Romano, M.; Saez, S. M. Romano; Adam, E. Romero; Rompotis, N.; Ronzani, M.; Roos, L.; Ros, E.; Rosati, S.; Rosbach, K.; Rose, P.; Rosenthal, O.; Rossetti, V.; Rossi, E.; Rossi, L. P.; Rosten, J. H. N.; Rosten, R.; Rotaru, M.; Roth, I.; Rothberg, J.; Rousseau, D.; Royon, C. R.; Rozanov, A.; Rozen, Y.; Ruan, X.; Rubbo, F.; Rubinskiy, I.; Rud, V. I.; Rudolph, M. S.; Rühr, F.; Ruiz-Martinez, A.; Rurikova, Z.; Rusakovich, N. A.; Ruschke, A.; Russell, H. L.; Rutherfoord, J. P.; Ruthmann, N.; Ryabov, Y. F.; Rybar, M.; Rybkin, G.; Ryu, S.; Ryzhov, A.; Saavedra, A. F.; Sabato, G.; Sacerdoti, S.; Sadrozinski, H. F.-W.; Sadykov, R.; Tehrani, F. Safai; Saha, P.; Sahinsoy, M.; Saimpert, M.; Saito, T.; Sakamoto, H.; Sakurai, Y.; Salamanna, G.; Salamon, A.; Loyola, J. E. Salazar; Salek, D.; De Bruin, P. H. Sales; Salihagic, D.; Salnikov, A.; Salt, J.; Salvatore, D.; Salvatore, F.; Salvucci, A.; Salzburger, A.; Sammel, D.; Sampsonidis, D.; Sanchez, A.; Sánchez, J.; Martinez, V. Sanchez; Sandaker, H.; Sandbach, R. L.; Sander, H. G.; Sanders, M. P.; Sandhoff, M.; Sandoval, C.; Sandstroem, R.; Sankey, D. P. C.; Sannino, M.; Sansoni, A.; Santoni, C.; Santonico, R.; Santos, H.; Castillo, I. Santoyo; Sapp, K.; Sapronov, A.; Saraiva, J. G.; Sarrazin, B.; Sasaki, O.; Sasaki, Y.; Sato, K.; Sauvage, G.; Sauvan, E.; Savage, G.; Savard, P.; Sawyer, C.; Sawyer, L.; Saxon, J.; Sbarra, C.; Sbrizzi, A.; Scanlon, T.; Scannicchio, D. A.; Scarcella, M.; Scarfone, V.; Schaarschmidt, J.; Schacht, P.; Schaefer, D.; Schaefer, R.; Schaeffer, J.; Schaepe, S.; Schaetzel, S.; Schäfer, U.; Schaffer, A. C.; Schaile, D.; Schamberger, R. D.; Scharf, V.; Schegelsky, V. A.; Scheirich, D.; Schernau, M.; Schiavi, C.; Schillo, C.; Schioppa, M.; Schlenker, S.; Schmieden, K.; Schmitt, C.; Schmitt, S.; Schmitz, S.; Schneider, B.; Schnellbach, Y. J.; Schnoor, U.; Schoeffel, L.; Schoening, A.; Schoenrock, B. D.; Schopf, E.; Schorlemmer, A. L. S.; Schott, M.; Schovancova, J.; Schramm, S.; Schreyer, M.; Schuh, N.; Schultens, M. J.; Schultz-Coulon, H.-C.; Schulz, H.; Schumacher, M.; Schumm, B. A.; Schune, Ph.; Schwanenberger, C.; Schwartzman, A.; Schwarz, T. A.; Schwegler, Ph.; Schweiger, H.; Schwemling, Ph.; Schwienhorst, R.; Schwindling, J.; Schwindt, T.; Sciolla, G.; Scuri, F.; Scutti, F.; Searcy, J.; Seema, P.; Seidel, S. C.; Seiden, A.; Seifert, F.; Seixas, J. M.; Sekhniaidze, G.; Sekhon, K.; Sekula, S. J.; Seliverstov, D. M.; Semprini-Cesari, N.; Serfon, C.; Serin, L.; Serkin, L.; Sessa, M.; Seuster, R.; Severini, H.; Sfiligoj, T.; Sforza, F.; Sfyrla, A.; Shabalina, E.; Shaikh, N. W.; Shan, L. Y.; Shang, R.; Shank, J. T.; Shapiro, M.; Shatalov, P. B.; Shaw, K.; Shaw, S. M.; Shcherbakova, A.; Shehu, C. Y.; Sherwood, P.; Shi, L.; Shimizu, S.; Shimmin, C. O.; Shimojima, M.; Shiyakova, M.; Shmeleva, A.; Saadi, D. Shoaleh; Shochet, M. J.; Shojaii, S.; Shrestha, S.; Shulga, E.; Shupe, M. A.; Sicho, P.; Sidebo, P. E.; Sidiropoulou, O.; Sidorov, D.; Sidoti, A.; Siegert, F.; Sijacki, Dj.; Silva, J.; Silverstein, S. B.; Simak, V.; Simard, O.; Simic, Lj.; Simion, S.; Simioni, E.; Simmons, B.; Simon, D.; Simon, M.; Sinervo, P.; Sinev, N. B.; Sioli, M.; Siragusa, G.; Sivoklokov, S. Yu.; Sjölin, J.; Sjursen, T. B.; Skinner, M. B.; Skottowe, H. P.; Skubic, P.; Slater, M.; Slavicek, T.; Slawinska, M.; Sliwa, K.; Slovak, R.; Smakhtin, V.; Smart, B. H.; Smestad, L.; Smirnov, S. Yu.; Smirnov, Y.; Smirnova, L. N.; Smirnova, O.; Smith, M. N. K.; Smith, R. W.; Smizanska, M.; Smolek, K.; Snesarev, A. A.; Snidero, G.; Snyder, S.; Sobie, R.; Socher, F.; Soffer, A.; Soh, D. A.; Sokhrannyi, G.; Sanchez, C. A. Solans; Solar, M.; Soldatov, E. Yu.; Soldevila, U.; Solodkov, A. A.; Soloshenko, A.; Solovyanov, O. V.; Solovyev, V.; Sommer, P.; Son, H.; Song, H. Y.; Sood, A.; Sopczak, A.; Sopko, V.; Sorin, V.; Sosa, D.; Sotiropoulou, C. L.; Soualah, R.; Soukharev, A. M.; South, D.; Sowden, B. C.; Spagnolo, S.; Spalla, M.; Spangenberg, M.; Spanò, F.; Sperlich, D.; Spettel, F.; Spighi, R.; Spigo, G.; Spiller, L. A.; Spousta, M.; Denis, R. D. St.; Stabile, A.; Stahlman, J.; Stamen, R.; Stamm, S.; Stanecka, E.; Stanek, R. W.; Stanescu, C.; Stanescu-Bellu, M.; Stanitzki, M. M.; Stapnes, S.; Starchenko, E. A.; Stark, G. H.; Stark, J.; Staroba, P.; Starovoitov, P.; Stärz, S.; Staszewski, R.; Steinberg, P.; Stelzer, B.; Stelzer, H. J.; Stelzer-Chilton, O.; Stenzel, H.; Stewart, G. A.; Stillings, J. A.; Stockton, M. C.; Stoebe, M.; Stoicea, G.; Stolte, P.; Stonjek, S.; Stradling, A. R.; Straessner, A.; Stramaglia, M. E.; Strandberg, J.; Strandberg, S.; Strandlie, A.; Strauss, M.; Strizenec, P.; Ströhmer, R.; Strom, D. M.; Stroynowski, R.; Strubig, A.; Stucci, S. A.; Stugu, B.; Styles, N. A.; Su, D.; Su, J.; Subramaniam, R.; Suchek, S.; Sugaya, Y.; Suk, M.; Sulin, V. V.; Sultansoy, S.; Sumida, T.; Sun, S.; Sun, X.; Sundermann, J. E.; Suruliz, K.; Susinno, G.; Sutton, M. R.; Suzuki, S.; Svatos, M.; Swiatlowski, M.; Sykora, I.; Sykora, T.; Ta, D.; Taccini, C.; Tackmann, K.; Taenzer, J.; Taffard, A.; Tafirout, R.; Taiblum, N.; Takai, H.; Takashima, R.; Takeda, H.; Takeshita, T.; Takubo, Y.; Talby, M.; Talyshev, A. A.; Tam, J. Y. C.; Tan, K. G.; Tanaka, J.; Tanaka, R.; Tanaka, S.; Tannenwald, B. B.; Araya, S. Tapia; Tapprogge, S.; Tarem, S.; Tartarelli, G. F.; Tas, P.; Tasevsky, M.; Tashiro, T.; Tassi, E.; Delgado, A. Tavares; Tayalati, Y.; Taylor, A. C.; Taylor, G. N.; Taylor, P. T. E.; Taylor, W.; Teischinger, F. A.; Teixeira-Dias, P.; Temming, K. K.; Temple, D.; Kate, H. Ten; Teng, P. K.; Teoh, J. J.; Tepel, F.; Terada, S.; Terashi, K.; Terron, J.; Terzo, S.; Testa, M.; Teuscher, R. J.; Theveneaux-Pelzer, T.; Thomas, J. P.; Thomas-Wilsker, J.; Thompson, E. N.; Thompson, P. D.; Thompson, R. J.; Thompson, A. S.; Thomsen, L. A.; Thomson, E.; Thomson, M.; Tibbetts, M. J.; Torres, R. E. Ticse; Tikhomirov, V. O.; Tikhonov, Yu. A.; Timoshenko, S.; Tipton, P.; Tisserant, S.; Todome, K.; Todorov, T.; Todorova-Nova, S.; Tojo, J.; Tokár, S.; Tokushuku, K.; Tolley, E.; Tomlinson, L.; Tomoto, M.; Tompkins, L.; Toms, K.; Tong, B.; Torrence, E.; Torres, H.; Pastor, E. Torró; Toth, J.; Touchard, F.; Tovey, D. R.; Trefzger, T.; Tricoli, A.; Trigger, I. M.; Trincaz-Duvoid, S.; Tripiana, M. F.; Trischuk, W.; Trocmé, B.; Trofymov, A.; Troncon, C.; Trottier-McDonald, M.; Trovatelli, M.; Truong, L.; Trzebinski, M.; Trzupek, A.; Tseng, J. C.-L.; Tsiareshka, P. V.; Tsipolitis, G.; Tsirintanis, N.; Tsiskaridze, S.; Tsiskaridze, V.; Tskhadadze, E. G.; Tsui, K. M.; Tsukerman, I. I.; Tsulaia, V.; Tsuno, S.; Tsybychev, D.; Tudorache, A.; Tudorache, V.; Tuna, A. N.; Tupputi, S. A.; Turchikhin, S.; Turecek, D.; Turgeman, D.; Turra, R.; Turvey, A. J.; Tuts, P. M.; Tyndel, M.; Ucchielli, G.; Ueda, I.; Ueno, R.; Ughetto, M.; Ukegawa, F.; Unal, G.; Undrus, A.; Unel, G.; Ungaro, F. C.; Unno, Y.; Unverdorben, C.; Urban, J.; Urquijo, P.; Urrejola, P.; Usai, G.; Usanova, A.; Vacavant, L.; Vacek, V.; Vachon, B.; Valderanis, C.; Santurio, E. Valdes; Valencic, N.; Valentinetti, S.; Valero, A.; Valery, L.; Valkar, S.; Vallecorsa, S.; Ferrer, J. A. Valls; Van Den Wollenberg, W.; Van Der Deijl, P. C.; van der Geer, R.; van der Graaf, H.; van Eldik, N.; van Gemmeren, P.; Van Nieuwkoop, J.; van Vulpen, I.; van Woerden, M. C.; Vanadia, M.; Vandelli, W.; Vanguri, R.; Vaniachine, A.; Vankov, P.; Vardanyan, G.; Vari, R.; Varnes, E. W.; Varol, T.; Varouchas, D.; Vartapetian, A.; Varvell, K. E.; Vasquez, J. G.; Vazeille, F.; Schroeder, T. Vazquez; Veatch, J.; Veloce, L. M.; Veloso, F.; Veneziano, S.; Ventura, A.; Venturi, M.; Venturi, N.; Venturini, A.; Vercesi, V.; Verducci, M.; Verkerke, W.; Vermeulen, J. C.; Vest, A.; Vetterli, M. C.; Viazlo, O.; Vichou, I.; Vickey, T.; Boeriu, O. E. Vickey; Viehhauser, G. H. A.; Viel, S.; Vigani, L.; Vigne, R.; Villa, M.; Perez, M. Villaplana; Vilucchi, E.; Vincter, M. G.; Vinogradov, V. B.; Vittori, C.; Vivarelli, I.; Vlachos, S.; Vlasak, M.; Vogel, M.; Vokac, P.; Volpi, G.; Volpi, M.; von der Schmitt, H.; von Toerne, E.; Vorobel, V.; Vorobev, K.; Vos, M.; Voss, R.; Vossebeld, J. H.; Vranjes, N.; Milosavljevic, M. Vranjes; Vrba, V.; Vreeswijk, M.; Vuillermet, R.; Vukotic, I.; Vykydal, Z.; Wagner, P.; Wagner, W.; Wahlberg, H.; Wahrmund, S.; Wakabayashi, J.; Walder, J.; Walker, R.; Walkowiak, W.; Wallangen, V.; Wang, C.; Wang, C.; Wang, F.; Wang, H.; Wang, H.; Wang, J.; Wang, J.; Wang, K.; Wang, R.; Wang, S. M.; Wang, T.; Wang, T.; Wang, X.; Wanotayaroj, C.; Warburton, A.; Ward, C. P.; Wardrope, D. R.; Washbrook, A.; Watkins, P. M.; Watson, A. T.; Watson, I. J.; Watson, M. F.; Watts, G.; Watts, S.; Waugh, B. M.; Webb, S.; Weber, M. S.; Weber, S. W.; Webster, J. S.; Weidberg, A. R.; Weinert, B.; Weingarten, J.; Weiser, C.; Weits, H.; Wells, P. S.; Wenaus, T.; Wengler, T.; Wenig, S.; Wermes, N.; Werner, M.; Werner, P.; Wessels, M.; Wetter, J.; Whalen, K.; Whallon, N. L.; Wharton, A. M.; White, A.; White, M. J.; White, R.; White, S.; Whiteson, D.; Wickens, F. J.; Wiedenmann, W.; Wielers, M.; Wienemann, P.; Wiglesworth, C.; Wiik-Fuchs, L. A. M.; Wildauer, A.; Wilk, F.; Wilkens, H. G.; Williams, H. H.; Williams, S.; Willis, C.; Willocq, S.; Wilson, J. A.; Wingerter-Seez, I.; Winklmeier, F.; Winston, O. J.; Winter, B. T.; Wittgen, M.; Wittkowski, J.; Wollstadt, S. J.; Wolter, M. W.; Wolters, H.; Wosiek, B. K.; Wotschack, J.; Woudstra, M. J.; Wozniak, K. W.; Wu, M.; Wu, M.; Wu, S. L.; Wu, X.; Wu, Y.; Wyatt, T. R.; Wynne, B. M.; Xella, S.; Xu, D.; Xu, L.; Yabsley, B.; Yacoob, S.; Yakabe, R.; Yamaguchi, D.; Yamaguchi, Y.; Yamamoto, A.; Yamamoto, S.; Yamanaka, T.; Yamauchi, K.; Yamazaki, Y.; Yan, Z.; Yang, H.; Yang, H.; Yang, Y.; Yang, Z.; Yao, W.-M.; Yap, Y. C.; Yasu, Y.; Yatsenko, E.; Wong, K. H. Yau; Ye, J.; Ye, S.; Yeletskikh, I.; Yen, A. L.; Yildirim, E.; Yorita, K.; Yoshida, R.; Yoshihara, K.; Young, C.; Young, C. J. S.; Youssef, S.; Yu, D. R.; Yu, J.; Yu, J. M.; Yu, J.; Yuan, L.; Yuen, S. P. Y.; Yusuff, I.; Zabinski, B.; Zaidan, R.; Zaitsev, A. M.; Zakharchuk, N.; Zalieckas, J.; Zaman, A.; Zambito, S.; Zanello, L.; Zanzi, D.; Zeitnitz, C.; Zeman, M.; Zemla, A.; Zeng, J. C.; Zeng, Q.; Zengel, K.; Zenin, O.; Ženiš, T.; Zerwas, D.; Zhang, D.; Zhang, F.; Zhang, G.; Zhang, H.; Zhang, J.; Zhang, L.; Zhang, R.; Zhang, R.; Zhang, X.; Zhang, Z.; Zhao, X.; Zhao, Y.; Zhao, Z.; Zhemchugov, A.; Zhong, J.; Zhou, B.; Zhou, C.; Zhou, L.; Zhou, L.; Zhou, M.; Zhou, N.; Zhu, C. G.; Zhu, H.; Zhu, J.; Zhu, Y.; Zhuang, X.; Zhukov, K.; Zibell, A.; Zieminska, D.; Zimine, N. I.; Zimmermann, C.; Zimmermann, S.; Zinonos, Z.; Zinser, M.; Ziolkowski, M.; Živković, L.; Zobernig, G.; Zoccoli, A.; Nedden, M. zur; Zurzolo, G.; Zwalinski, L.

    2016-10-01

    The performance of the jet trigger for the ATLAS detector at the LHC during the 2011 data taking period is described. During 2011 the LHC provided proton-proton collisions with a centre-of-mass energy of 7 TeV and heavy ion collisions with a 2.76 TeV per nucleon-nucleon collision energy. The ATLAS trigger is a three level system designed to reduce the rate of events from the 40 MHz nominal maximum bunch crossing rate to the approximate 400 Hz which can be written to offline storage. The ATLAS jet trigger is the primary means for the online selection of events containing jets. Events are accepted by the trigger if they contain one or more jets above some transverse energy threshold. During 2011 data taking the jet trigger was fully efficient for jets with transverse energy above 25 GeV for triggers seeded randomly at Level 1. For triggers which require a jet to be identified at each of the three trigger levels, full efficiency is reached for offline jets with transverse energy above 60 GeV. Jets reconstructed in the final trigger level and corresponding to offline jets with transverse energy greater than 60 GeV, are reconstructed with a resolution in transverse energy with respect to offline jets, of better than 4 % in the central region and better than 2.5 % in the forward direction.

  1. A compact fiber optics-based heterodyne combined normal and transverse displacement interferometer.

    PubMed

    Zuanetti, Bryan; Wang, Tianxue; Prakash, Vikas

    2017-03-01

    While Photonic Doppler Velocimetry (PDV) has become a common diagnostic tool for the measurement of normal component of particle motion in shock wave experiments, this technique has not yet been modified for the measurement of combined normal and transverse motion, as needed in oblique plate impact experiments. In this paper, we discuss the design and implementation of a compact fiber-optics-based heterodyne combined normal and transverse displacement interferometer. Like the standard PDV, this diagnostic tool is assembled using commercially available telecommunications hardware and uses a 1550 nm wavelength 2 W fiber-coupled laser, an optical focuser, and single mode fibers to transport light to and from the target. Two additional optical probes capture first-order beams diffracted from a reflective grating at the target free-surface and deliver the beams past circulators and a coupler where the signal is combined to form a beat frequency. The combined signal is then digitized and analyzed to determine the transverse component of the particle motion. The maximum normal velocity that can be measured by this system is limited by the equivalent transmission bandwidth (3.795 GHz) of the combined detector, amplifier, and digitizer and is estimated to be ∼2.9 km/s. Sample symmetric oblique plate-impact experiments are performed to demonstrate the capability of this diagnostic tool in the measurement of the combined normal and transverse displacement particle motion.

  2. [Anatomical study of muscular latissimus dorsi surface vascularized by the transverse branch of thoraco-dorsal artery].

    PubMed

    Boucher, F; Pinatel, B; Shipkov, H; Mertens, P; Rouviere, O; Braye, F; Mojallal, A

    2014-10-01

    The latissimus dorsi muscle flap is a type V according to Mathes and Nahai. It is vascularized by a proximal main pedicle represented by the thoraco-dorsal pedicle and pedicle distal accessory represented by the dorsal branches of the posterior intercostal arteries. The main thoraco-dorsal pedicle has a descending branch and a transverse branch. This anatomical study clarifies the muscular territory vascularized by the transverse branch of thoraco-dorsal artery for a secondary use after harvesting a thoraco-dorsal artery perforator flap or a muscle-sparing latissimus dorsi flap. Our study focused on ten dissections latissimus dorsi muscle taken from five fresh cadavers chest, carried out within the University Department of Anatomy. The descending branch of thoraco-dorsal artery was ligated, the transverse branch was cannulated and injected with a mixture of barium sulfate/gelatin. After freezing, a static angiotomodensitometry (3D) of each flap was performed. The average muscular surface vascularized by the transverse branch is measured at 80% (77% minimum value, maximum value 83%) of the complete latissimus dorsi muscle. Intermuscular connections between the two branches of thoraco-dorsal pedicle were shown. The use of a ipsilateral latissimus dorsi muscle is a therapeutic option after harvesting a thoraco-dorsal artery perforator flap (TAP) or a muscle-sparing latissimus dorsi flap (MSLD-flap). Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  3. Strong focusing effect of 660 nm laser by microsized tapered glass tubes with different diameters

    NASA Astrophysics Data System (ADS)

    Lin, Chongnan; Luo, Xujia; Zhu, Xiaoyang; Zhu, Li; Wang, Hongcheng; Zhang, Ao; Xu, Runyu; Qu, Zheng; Chen, Ximeng; Zhang, Weiyi; Shao, Jianxiong

    2017-09-01

    A laser with a wavelength of 660 nm was focused by microsized tapered glass tubes with different diameters of the exit. By using the 3-μm optical fiber and micrometer displacement stages, we measured the light intensity distribution around the focal spot, the focal distance, and the transmission coefficient of the light transmitted through these tubes. The focusing effect for the glass tubes with smaller outlet diameters of the exit was found to be much stronger than those with larger diameters of the exit. Furthermore, the dependence of the size and distance and the maximum intensity of the focal spot on the tubes' diameter of exit are obtained.

  4. Extended supraclavicular fasciocutaneous island flap based on the transverse cervical artery for head and neck reconstruction after cancer ablation.

    PubMed

    Chen, Wei-Liang; Zhang, Da-ming; Yang, Zhao-hui; Huang, Zhi-quan; Wang, Jian-guang; Zhang, Bin; Li, Jing-song

    2010-10-01

    This clinical study assessed a pedicled supraclavicular fasciocutaneous island flap (SFIF) based on the transverse cervical artery that was extended to include shoulder skin for reconstructing the head and neck. Pedicled SFIFs extended to include the shoulder skin based on the cutaneous feeder vessels and perforator vessels in the deep fascia of the transverse cervical artery were designed for 24 patients with defects of the head and neck after cancer ablation. Preoperative 3-dimensional computed tomographic angiography was performed in all patients. The patients consisted of 15 men and 9 women ranging in age from 24 to 73 years. The primary lesions included squamous cell carcinoma of the tongue, buccal mucosa, floor of the mouth, oropharynx, palate, and lower gingiva. Three-dimensional computed tomographic angiography showed that the transverse cervical artery arose from the thyrocervical trunk in 13 cases and from the subclavian artery in 11 cases. The diameter of the artery ranged from 0.15 to 0.24 cm. The size of flaps ranged from 4 × 8 cm to 6 × 12 cm, and the mean length of the vascular pedicle was approximately 18.5 cm. Of the flaps, 23 survived completely, for a success rate of 95.8%. Three patients underwent radiotherapy, and the follow-up period ranged from 3 to 12 months. One patient died of local tumor recurrence, and cervical recurrences developed in 3 patients. An SFIF extended to include the shoulder skin based on the cutaneous feeder vessels and perforator vessels in the deep fascia of the transverse cervical artery is a useful, viable option for defects of the head and neck after cancer ablation. Copyright © 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Depth-Dependent Transverse Shear Properties of the Human Corneal Stroma

    PubMed Central

    Petsche, Steven J.; Chernyak, Dimitri; Martiz, Jaime; Levenston, Marc E.

    2012-01-01

    Purpose. To measure the transverse shear modulus of the human corneal stroma and its profile through the depth by mechanical testing, and to assess the validity of the hypothesis that the shear modulus will be greater in the anterior third due to increased interweaving of lamellae. Methods. Torsional rheometry was used to measure the transverse shear properties of 6 mm diameter buttons of matched human cadaver cornea pairs. One cornea from each pair was cut into thirds through the thickness with a femtosecond laser and each stromal third was tested individually. The remaining intact corneas were tested to measure full stroma shear modulus. The shear modulus from a 1% shear strain oscillatory test was measured at various levels of axial compression for all samples. Results. After controlling for axial compression, the transverse shear moduli of isolated anterior layers were significantly higher than central and posterior layers. Mean modulus values at 0% axial strain were 7.71 ± 6.34 kPa in the anterior, 1.99 ± 0.45 kPa in the center, 1.31 ± 1.01 kPa in the posterior, and 9.48 ± 2.92 kPa for full thickness samples. A mean equilibrium compressive modulus of 38.7 ± 8.6 kPa at 0% axial strain was calculated from axial compression measured during the shear tests. Conclusions. Transverse shear moduli are two to three orders of magnitude lower than tensile moduli reported in the literature. The profile of shear moduli through the depth displayed a significant increase from posterior to anterior. This gradient supports the hypothesis and corresponds to the gradient of interwoven lamellae seen in imaging of stromal cross-sections. PMID:22205608

  6. Development of a liquid tin microjet target for an efficient laser-produced plasma extreme ultraviolet source.

    PubMed

    Higashiguchi, Takeshi; Hamada, Masaya; Kubodera, Shoichi

    2007-03-01

    A regenerative tin liquid microjet target was developed for a high average power extreme ultraviolet (EUV) source. The diameter of the target was smaller than 160 microm and good vacuum lower than 0.5 Pa was maintained during the operation. A maximum EUV conversion efficiency of 1.8% at the Nd:yttrium-aluminum-garnet laser intensity of around 2 x 10(11) Wcm(2) with a spot diameter of 175 microm (full width at half maximum) was observed. The angular distribution of the EUV emission remained almost isotropic, whereas suprathermal ions mainly emerged toward the target normal.

  7. Development of a liquid tin microjet target for an efficient laser-produced plasma extreme ultraviolet source

    NASA Astrophysics Data System (ADS)

    Higashiguchi, Takeshi; Hamada, Masaya; Kubodera, Shoichi

    2007-03-01

    A regenerative tin liquid microjet target was developed for a high average power extreme ultraviolet (EUV) source. The diameter of the target was smaller than 160 μm and good vacuum lower than 0.5 Pa was maintained during the operation. A maximum EUV conversion efficiency of 1.8% at the Nd:yttrium-aluminum-garnet laser intensity of around 2×1011 W/cm2 with a spot diameter of 175 μm (full width at half maximum) was observed. The angular distribution of the EUV emission remained almost isotropic, whereas suprathermal ions mainly emerged toward the target normal.

  8. The provision of clearances accuracy in piston - cylinder mating

    NASA Astrophysics Data System (ADS)

    Glukhov, V. I.; Shalay, V. V.

    2017-08-01

    The paper is aimed at increasing the quality of the pumping equipment in oil and gas industry. The main purpose of the study is to stabilize maximum values of productivity and durability of the pumping equipment based on the selective assembly of the cylinder-piston kinematic mating by optimization criterion. It is shown that the minimum clearance in the piston-cylinder mating is formed by maximum material dimensions. It is proved that maximum material dimensions are characterized by their own laws of distribution within the tolerance limits for the diameters of the cylinder internal mirror and the outer cylindrical surface of the piston. At that, their dispersion zones should be divided into size groups with a group tolerance equal to half the tolerance for the minimum clearance. The techniques for measuring the material dimensions - the smallest cylinder diameter and the largest piston diameter according to the envelope condition - are developed for sorting them into size groups. Reliable control of the dimensions precision ensures optimal minimum clearances of the piston-cylinder mating in all the size groups of the pumping equipment, necessary for increasing the equipment productivity and durability during the production, operation and repair processes.

  9. Mapping of an ultrasonic bath for ultrasound assisted extraction of mangiferin from Mangifera indica leaves.

    PubMed

    Kulkarni, Vrushali M; Rathod, Virendra K

    2014-03-01

    The present work deals with the mapping of an ultrasonic bath for the maximum extraction of mangiferin from Mangifera indica leaves. I3(-) liberation experiments (chemical transformations) and extraction (physical transformations) were carried out at different locations in an ultrasonic bath and compared. The experimental findings indicated a similar trend in variation in an ultrasonic bath by both these methods. Various parameters such as position and depth of vessel in an ultrasonic bath, diameter and shape of a vessel, frequency and input power which affect the extraction yield have been studied in detail. Maximum yield of mangiferin obtained was approximately 31 mg/g at optimized parameters: distance of 2.54 cm above the bottom of the bath, 7 cm diameter of vessel, flat bottom vessel, 6.35 cm liquid height, 122 W input power and 25 kHz frequency. The present work indicates that the position and depth of vessel in an ultrasonic bath, diameter and shape of a vessel, frequency and input power have significant effect on the extraction yield. This work can be used as a base for all ultrasonic baths to obtain maximum efficiency for ultrasound assisted extraction. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Remineralization of primary tooth enamel from individuals with Down syndrome.

    PubMed

    Okamoto, Takuma; Shibata, Munenori; Tsuboi, Shinji; Nakagaki, Haruo; Fukuta, Osamu; Kusabe, Yoshitaka; Inukai, Junko

    2011-01-01

    The purpose of this study was to clarify the characteristics of primary tooth enamel of Down syndrome patients (DSPs). We examined 9 primary teeth of Down syndrome children and 11 primary teeth of normally developed children to investigate the remineralization processes of enamel by transverse microradiography and X ray micro analyzer (XMA). Mineral loss, lesion depth, maximum mineral value, minimum mineral value, depth of maximum mineral value, and depth of minimum mineral value were used to analyze transverse microradiography (TMR). In addition, we calculated the percentage of enamel remineralization. All the parameters in the 2 groups showed marked recovery. The results indicated that the Down syndrome group was significantly remineralized the same way as the control group. According to the comparison of mineral content distribution by XMA, the content distribution of magnesium was different between the 2 groups. While recovery through remineralization of primary teeth was similar between Down syndrome children and normally developed children, the mechanism of remineralization process may be different between the 2 groups; consequently, magnesium may be considered as one of the factors affecting recovery.

  11. Transverse Wave Induced Kelvin–Helmholtz Rolls in Spicules

    NASA Astrophysics Data System (ADS)

    Antolin, P.; Schmit, D.; Pereira, T. M. D.; De Pontieu, B.; De Moortel, I.

    2018-03-01

    In addition to their jet-like dynamic behavior, spicules usually exhibit strong transverse speeds, multi-stranded structure, and heating from chromospheric to transition region temperatures. In this work we first analyze Hinode and IRIS observations of spicules and find different behaviors in terms of their Doppler velocity evolution and collective motion of their sub-structure. Some have a Doppler shift sign change that is rather fixed along the spicule axis, and lack coherence in the oscillatory motion of strand-like structure, matching rotation models, or long-wavelength torsional Alfvén waves. Others exhibit a Doppler shift sign change at maximum displacement and coherent motion of their strands, suggesting a collective magnetohydrodynamic (MHD) wave. By comparing with an idealized 3D MHD simulation combined with radiative transfer modeling, we analyze the role of transverse MHD waves and associated instabilities in spicule-like features. We find that transverse wave induced Kelvin–Helmholtz (TWIKH) rolls lead to coherence of strand-like structure in imaging and spectral maps, as seen in some observations. The rapid transverse dynamics and the density and temperature gradients at the spicule boundary lead to ring-shaped Mg II k and Ca II H source functions in the transverse cross-section, potentially allowing IRIS to capture the Kelvin–Helmholtz instability dynamics. Twists and currents propagate along the spicule at Alfvénic speeds, and the temperature variations within TWIKH rolls, produce the sudden appearance/disappearance of strands seen in Doppler velocity and in Ca II H intensity. However, only a mild intensity increase in higher-temperature lines is obtained, suggesting there is an additional heating mechanism at work in spicules.

  12. Performance Assessment of a Large Scale Pulsejet- Driven Ejector System

    NASA Technical Reports Server (NTRS)

    Paxson, Daniel E.; Litke, Paul J.; Schauer, Frederick R.; Bradley, Royce P.; Hoke, John L.

    2006-01-01

    Unsteady thrust augmentation was measured on a large scale driver/ejector system. A 72 in. long, 6.5 in. diameter, 100 lb(sub f) pulsejet was tested with a series of straight, cylindrical ejectors of varying length, and diameter. A tapered ejector configuration of varying length was also tested. The objectives of the testing were to determine the dimensions of the ejectors which maximize thrust augmentation, and to compare the dimensions and augmentation levels so obtained with those of other, similarly maximized, but smaller scale systems on which much of the recent unsteady ejector thrust augmentation studies have been performed. An augmentation level of 1.71 was achieved with the cylindrical ejector configuration and 1.81 with the tapered ejector configuration. These levels are consistent with, but slightly lower than the highest levels achieved with the smaller systems. The ejector diameter yielding maximum augmentation was 2.46 times the diameter of the pulsejet. This ratio closely matches those of the small scale experiments. For the straight ejector, the length yielding maximum augmentation was 10 times the diameter of the pulsejet. This was also nearly the same as the small scale experiments. Testing procedures are described, as are the parametric variations in ejector geometry. Results are discussed in terms of their implications for general scaling of pulsed thrust ejector systems

  13. Pyrolysis of Large Black Liquor Droplets

    NASA Technical Reports Server (NTRS)

    Bartkus, Tadas P.; Dietrich, Daniel L.; T'ien, James S.; Wessel, Richard A.

    2007-01-01

    This paper presents the results of experiments involving the pyrolysis of large black liquor droplets in the NASA KC-135 reduced gravity aircraft. The reduced gravity environment facilitated the study of droplets up to 9 mm in diameter extending the results of previous studies to droplet sizes that are similar to those encountered in recovery boilers. Single black liquor droplets were rapidly inserted into a 923 K oven. The primary independent variables were the initial droplet diameter (0.5 mm to 9 mm), the black liquor solids content (66.12% - 72.9% by mass), and the ambient oxygen mole fraction (0.0 - 0.21). Video records of the experiments provided size and shape of the droplets as a function of time. The results show that the particle diameter at the end of the drying stage (D(sub DRY)) increases linearly with the initial particle diameter (D(sub O)). The results further show that the ratio of the maximum swollen diameter (D(sub MAX)) to D(sub O) decreases with increasing D(sub O) for droplets with D(sub O) less than 4 mm. This ratio was independent of D(sub O) for droplets with D(sub O) greater than 4 mm. The particle is most spherical at the end of drying, and least spherical at maximum swollen size, regardless of initial sphericity and droplet size.

  14. Pyrolysis of Large Black Liquor Droplets

    NASA Technical Reports Server (NTRS)

    Bartkus, Tadas P.; T'ien, James S.; Dietrich, Daniel L.; Wessel, Richard A.

    2007-01-01

    This paper presents the results of experiments involving the pyrolysis of large black liquor droplets in the NASA KC-135 reduced gravity aircraft. The reduced gravity environment facilitated the study of droplets up to 9 mm in diameter extending the results of previous studies to droplet sizes that are similar to those encountered in recovery boilers. Single black liquor droplets were rapidly inserted into a 923 K oven. The primary independent variables were the initial droplet diameter (0.5 mm to 9 mm), the black liquor solids content (66.12% - 72.9% by mass), and the ambient oxygen mole fraction (0.0 - 0.21). Video records of the experiments provided size and shape of the droplets as a function of time. The results show that the particle diameter at the end of the drying stage (D(sub DRY) ) increases linearly with the initial particle diameter (D(sub O)). The results further show that the ratio of the maximum swollen diameter (D(sub MAX)) to D(sub O) decreases with increasing D(sub O) for droplets with D(sub O) less than 4 mm. This ratio was independent of D(sub O) for droplets with D(sub O) greater than 4 mm. The particle is most spherical at the end of drying, and least spherical at maximum swollen size, regardless of initial sphericity and droplet size.

  15. The effect of cervical preflaring using different rotary nickel-titanium systems on the accuracy of apical file size determination.

    PubMed

    Tennert, Christian; Herbert, Josef; Altenburger, Markus Jörg; Wrbas, Karl-Thomas

    2010-10-01

    An exact determination of the apical root canal diameter is crucial for correct cleaning and shaping of a root canal. The aim of this study was to investigate the discrepancies of the initial apical root canal diameter and the diameter that is measured by the initial apical file (IAF) after cervical flaring using current rotary nickel-titanium systems. Mesiobuccal canals of 40 extracted mandibular molars were randomly assigned to four groups. In the first group, root canals were not flared. Root canals of the other groups were preflared using FlexMaster (VDW, Munich, Germany), ProTaper (Dentsply, Konstanz, Germany), or RaCe (FKG Dentaire, Genf, Switzerland) instruments. The tooth length was determined by inserting an ISO 06 K-file to the apical foramen. The working length (WL) was set 1 mm short of the apical foramen. File sizes were increased after binding sensation was felt at the WL. Transversal sections of the WL regions were examined under stereomicroscope, and the diameter of the root canal and the IAF at WL were assessed. Canals preflared with RaCe instruments had the lowest discrepancy between the apical root canal diameter and the IAF diameter (15.7 ± 9.7 μm) followed by ProTaper (22.2 ± 11.0 μm) and FlexMaster (35.0 ± 17.2 μm). Preflaring of root canals prevents underestimation of the actual apical root canal diameter. The type of instruments used for preflaring show differences on the accuracy of IAF determination. Preflaring with larger tapered instruments leads to a more accurate apical sizing, and this information is crucial concerning the appropriate final diameter for complete apical shaping. Copyright © 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. Apparatus for precision focussing and positioning of a beam waist on a target

    NASA Technical Reports Server (NTRS)

    Lynch, Dana H. (Inventor); Gunter, William D. (Inventor); Mcalister, Kenneth W. (Inventor)

    1991-01-01

    The invention relates to optical focussing apparatus and, more particularly, to optical apparatus for focussing a highly collimated Gaussian beam which provides independent and fine control over the focus waist diameter, the focus position both along the beam axis and transverse to the beam, and the focus angle. A beam focussing and positioning apparatus provides focussing and positioning for the waist of a waisted beam at a desired location on a target such as an optical fiber. The apparatus includes a first lens, having a focal plane f sub 1, disposed in the path of an incoming beam and a second lens, having a focal plane f sub 2 and being spaced downstream from the first lens by a distance at least equal to f sub 1 + 10 f sub 2, which cooperates with the first lens to focus the waist of the beam on the target. A rotatable optical device, disposed upstream of the first lens, adjusts the angular orientation of the beam waist. The transverse position of the first lens relative to the axis of the beam is varied to control the transverse position of the beam waist relative to the target (a fiber optic as shown) while the relative axial positions of the lenses are varied to control the diameter of the beam waist and to control the axial position of the beam waist. Mechanical controllers C sub 1, C sub 2, C sub 3, C sub 4, and C sub 5 control the elements of the optical system. How seven adjustments can be made to correctly couple a laser beam into an optical fiber is illustrated. Prior art systems employing optical techniques to couple a laser beam into an optical fiber or other target simply do not provide the seven necessary adjustments. The closest known prior art, a Newport coupler, provides only two of the seven required adjustments.

  17. Effects of a monophasic combined oral contraceptive containing nomegestrol acetate and 17 beta-oestradiol on ovarian function in comparison to a monophasic combined oral contraceptive containing drospirenone and ethinylestradiol.

    PubMed

    Duijkers, Ingrid J M; Klipping, Christine; Grob, Paul; Korver, Tjeerd

    2010-10-01

    To compare the effects on ovarian activity of two oral contraceptives containing nomegestrol acetate (NOMAC)/17 beta-oestradiol (E2) or drospirenone (DRSP)/ethinylestradiol (EE). In this open-label, randomised, six-cycle study, 32 subjects using NOMAC/E2 (2.5-1.5 mg; 24/4-day regimen) were compared to 16 subjects using DRSP/EE (3 mg-30 microg; 21/7-day regimen). Measurements included serum oestradiol, progesterone, follicle stimulating hormone (FSH) and luteinising hormone (LH), and ultrasonography of follicular diameter. No ovulations occurred during treatment. Progesterone was fully suppressed, with mean maximum values <2 nmol/l in both groups over all cycles. For NOMAC/E2, mean maximum follicular diameter decreased from 19.3 mm before treatment to between 6.9 and 8.2 mm during treatment, with no subject having a follicular diameter ≥15 mm. For DRSP/EE, a decrease from 19.6 to between 7.4 and 10.8 mm was observed, with two subjects (12.5%) having a maximum follicle diameter ≥15 mm. These findings were consistent with observed FSH reductions; full suppression of LH surges was observed in both groups. Post-treatment return of ovulation in both groups occurred on average 21 days after the last active tablet intake. NOMAC/E2 achieves consistent ovulation inhibition, with suppressive effects on the ovaries at least similar to those of DRSP/EE.

  18. Distributed transverse stress measurement along an optic fiber using polarimetric OFDR.

    PubMed

    Wei, Changjiang; Chen, Hongxin; Chen, Xiaojun; Chen, David; Li, Zhihong; Yao, X Steve

    2016-06-15

    We report a novel polarimetric optical frequency domain reflectometer (P-OFDR) that can simultaneously measure both space-resolved transverse stresses and light back-reflections along an optic fiber with sub-mm spatial resolution. By inducing transversal stresses and optical back-reflections at multiple points along a length of optic fiber, we demonstrate that our system can unambiguously distinguish the stresses from the back-reflections of a fiber with a fiber length longer than 800 m, a spatial resolution of 0.5 mm, a maximum stress level of up to 200 kpsi (1379 Mpa), a minimum stress of about 10 kpsi (69 Mpa), and a stress measurement uncertainty of 10%. We show that our P-OFDR can clearly identify the locations and magnitudes of the stresses inside a fiber coil induced during a fiber winding process. The P-OFDR can be used for fiber health monitoring for critical fiber links, fiber gyro coil characterization, and other distributed fiber sensing applications.

  19. 40 CFR 204.55-3 - Configuration identification.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... compressor stages. (3) Maximum pressure (psi). (4) Air intake system of compressor: (i) Number of filters; (ii) Type of filters. (5) The engine system: (i) Number of cylinders and configuration (L-6, V-8, V-12..., water cooled. (7) Fan: (i) Diameter; (ii) Maximum fan rpm. (8) The compressor enclosure: (i) Height...

  20. 40 CFR 204.55-3 - Configuration identification.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... compressor stages. (3) Maximum pressure (psi). (4) Air intake system of compressor: (i) Number of filters; (ii) Type of filters. (5) The engine system: (i) Number of cylinders and configuration (L-6, V-8, V-12..., water cooled. (7) Fan: (i) Diameter; (ii) Maximum fan rpm. (8) The compressor enclosure: (i) Height...

  1. 40 CFR 204.55-3 - Configuration identification.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... compressor stages. (3) Maximum pressure (psi). (4) Air intake system of compressor: (i) Number of filters; (ii) Type of filters. (5) The engine system: (i) Number of cylinders and configuration (L-6, V-8, V-12..., water cooled. (7) Fan: (i) Diameter; (ii) Maximum fan rpm. (8) The compressor enclosure: (i) Height...

  2. 40 CFR 204.55-3 - Configuration identification.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... compressor stages. (3) Maximum pressure (psi). (4) Air intake system of compressor: (i) Number of filters; (ii) Type of filters. (5) The engine system: (i) Number of cylinders and configuration (L-6, V-8, V-12..., water cooled. (7) Fan: (i) Diameter; (ii) Maximum fan rpm. (8) The compressor enclosure: (i) Height...

  3. Near-Wall Velocity Field Measurements of a Very Low Momentum Flux Transverse Jet

    DTIC Science & Technology

    2014-06-01

    nozzle was used to generate olive oil droplets approximately 1 μm in diameter with approximately 20 particles per 32 x 32 px interrogation region...pair, two for each window size, 64 x 64 px and 32 x 32 px. Vectors with cross-correlation peak ratios Q < 1.7 were eliminated and replaced with a... vector whose value was interpolated by using values of its nearest neighbors. III. Results and Discussion A total of five momentum flux ratios were

  4. Intense Ion Pulses for Radiation Effects Research

    DTIC Science & Technology

    2017-04-01

    station; here, the time dependent beam current can be measured with a fast Faraday cup (ə ns time resolution). The transverse distribution of the...focused into a spot with a diameter of about 2 mm [8]. The helium ion current and the integrated charge ver- sus time, measured with the fast Faraday cup...target measured with the fast Faraday cup. The sharp peak in the current measurement shows the beam pulse compression from 1 μs to a few ns. The full

  5. Numerical Simulation of the Vortex-Induced Vibration of A Curved Flexible Riser in Shear Flow

    NASA Astrophysics Data System (ADS)

    Zhu, Hong-jun; Lin, Peng-zhi

    2018-06-01

    A series of fully three-dimensional (3D) numerical simulations of flow past a free-to-oscillate curved flexible riser in shear flow were conducted at Reynolds number of 185-1015. The numerical results obtained by the two-way fluid-structure interaction (FSI) simulations are in good agreement with the experimental results reported in the earlier study. It is further found that the frequency transition is out of phase not only in the inline (IL) and crossflow (CF) directions but also along the span direction. The mode competition leads to the non-zero nodes of the rootmean- square (RMS) amplitude and the relatively chaotic trajectories. The fluid-structure interaction is to some extent reflected by the transverse velocity of the ambient fluid, which reaches the maximum value when the riser reaches the equilibrium position. Moreover, the local maximum transverse velocities occur at the peak CF amplitudes, and the values are relatively large when the vibration is in the resonance regions. The 3D vortex columns are shed nearly parallel to the axis of the curved flexible riser. As the local Reynolds number increases from 0 at the bottom of the riser to the maximum value at the top, the wake undergoes a transition from a two-dimensional structure to a 3D one. More irregular small-scale vortices appeared at the wake region of the riser, undergoing large amplitude responses.

  6. A comparison of hydraulic architecture in three similarly sized woody species differing in their maximum potential height.

    PubMed

    McCulloh, Katherine A; Johnson, Daniel M; Petitmermet, Joshua; McNellis, Brandon; Meinzer, Frederick C; Lachenbruch, Barbara

    2015-07-01

    The physiological mechanisms underlying the short maximum height of shrubs are not understood. One possible explanation is that differences in the hydraulic architecture of shrubs compared with co-occurring taller trees prevent the shrubs from growing taller. To explore this hypothesis, we examined various hydraulic parameters, including vessel lumen diameter, hydraulic conductivity and vulnerability to drought-induced embolism, of three co-occurring species that differed in their maximum potential height. We examined one species of shrub, one short-statured tree and one taller tree. We worked with individuals that were approximately the same age and height, which was near the maximum for the shrub species. A number of variables correlated with the maximum potential height of the species. For example, vessel diameter and vulnerability to embolism both increased while wood density declined with maximum potential height. The difference between the pressure causing 50% reduction in hydraulic conductance in the leaves and the midday leaf water potential (the leaf's hydraulic safety margin) was much larger in the shrub than the other two species. In general, trends were consistent with understory shrubs having a more conservative life history strategy than co-occurring taller species. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Evaluation of the Transverse Displacement of the Proximal Segment After Bilateral Sagittal Split Ramus Osteotomy With Different Lingual Split Patterns and Advancement Amounts Using the Finite Element Method.

    PubMed

    Dai, Zhi; Hou, Min; Ma, Wen; Song, Da-Li; Zhang, Chun-Xiang; Zhou, Wei-Yuan

    2016-11-01

    To evaluate transverse displacement of the proximal segment after bilateral sagittal split ramus osteotomy (BSSO) advancement with different lingual split patterns and advancement amounts and to determine the influential factors related to mandibular width. A 3-dimensional finite element model of the mandible including the temporomandibular joint was created for a presurgical simulation and for BSSO with lingual split patterns I (T1; Hunsuck split) and II (T2; Obwegeser split). The mandible was advanced 3 mm (A3) and 8 mm (A8) and fixated with a conventional titanium plate. Ansys software was used to measure the linear distances of the interproximal segments and to analyze the transverse displacement distribution of proximal segments after applying the load of masticatory muscle force groups. After surgical simulation, T1A3, T1A8, T2A3, and T2A8 showed increased transverse widths (mean, 2.99, 4.70, 2.36, and 4.42 mm, respectively). For transverse augmentation, there was a statistically significant difference between the 2 different mandibular advancement amounts in T1 and in T2 (P ≤ .000), but no significant differences was observed between T1 and T2 (P ≥ .058). The maximum transverse displacement distribution in the proximal segment was measured around the gonial area, and the early contact area was found near the border between the horizontal and sagittal osteotomy lines. Transverse displacements of proximal segments occur after BSSO advancement with T1 and T2 and transverse augmentation has statistically meaningful effects depending on the amount of advancement; however, no differences in transverse augmentation between T1 and T2 were identified. The fulcrum caused by the early contact between the proximal and distal segments could be an influential factor related to mandibular width. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Rewetting of hot vertical rod during jet impingement surface cooling

    NASA Astrophysics Data System (ADS)

    Agrawal, Chitranjan; Kumar, Ravi; Gupta, Akhilesh; Chatterjee, Barun

    2016-06-01

    A stainless steel (SS-316) vertical rod of 12 mm diameter at 800 ± 10 °C initial temperature was cooled by normal impinging round water jet. The surface rewetting phenomenon was investigated for a range of jet diameter 2.5-4.8 mm and jet Reynolds number 5000-24,000 using a straight tube type nozzle. The investigation were made from the stagnation point to maximum 40 mm downstream locations, simultaneously for both upside and downside directions. The cooling performance of the vertical rod was evaluated on the basis of rewetting parameters i.e. rewetting temperature, wetting delay, rewetting velocity and the maximum surface heat flux. Two separate Correlations have been proposed for the dimensionless rewetting velocity in terms of rewetting number and the maximum surface heat flux that predicts the experimental data within an error band of ±20 and ±15 % respectively.

  9. Mechanical coupling limits the density and quality of self-organized carbon nanotube growth

    NASA Astrophysics Data System (ADS)

    Bedewy, Mostafa; Hart, A. John

    2013-03-01

    Aligned carbon nanotube (CNT) structures are promising for many applications; however, as-grown CNT "forests" synthesized by chemical vapor deposition (CVD) are typically low-density and mostly comprise tortuous defective CNTs. Here, we present evidence that the density and alignment of self-organized CNT growth is limited by mechanical coupling among CNTs in contact, in combination with their diameter-dependent growth rates. This study is enabled by comprehensive X-ray characterization of the spatially and temporally-varying internal morphology of CNT forests. Based on this data, we model the time evolution and diameter-dependent scaling of the ensuing mechanical forces on catalyst nanoparticles during CNT growth, which arise from the mismatch between the collective lengthening rate of the forest and the diameter-dependent growth rates of individual CNTs. In addition to enabling self-organization of CNTs into forests, time-varying forces between CNTs in contact dictate the hierarchical tortuous morphology of CNT forests, and may be sufficient to influence the structural quality of CNTs. These forces reach a maximum that is coincident with the maximum density observed in our growth process, and are proportional to CNT diameter. Therefore, we propose that improved manufacturing strategies for self-organized CNTs should consider both chemical and mechanical effects. This may be especially necessary to achieve high density CNT forests with low defect density, such as for improved thermal interfaces and high-permeability membranes.Aligned carbon nanotube (CNT) structures are promising for many applications; however, as-grown CNT "forests" synthesized by chemical vapor deposition (CVD) are typically low-density and mostly comprise tortuous defective CNTs. Here, we present evidence that the density and alignment of self-organized CNT growth is limited by mechanical coupling among CNTs in contact, in combination with their diameter-dependent growth rates. This study is enabled by comprehensive X-ray characterization of the spatially and temporally-varying internal morphology of CNT forests. Based on this data, we model the time evolution and diameter-dependent scaling of the ensuing mechanical forces on catalyst nanoparticles during CNT growth, which arise from the mismatch between the collective lengthening rate of the forest and the diameter-dependent growth rates of individual CNTs. In addition to enabling self-organization of CNTs into forests, time-varying forces between CNTs in contact dictate the hierarchical tortuous morphology of CNT forests, and may be sufficient to influence the structural quality of CNTs. These forces reach a maximum that is coincident with the maximum density observed in our growth process, and are proportional to CNT diameter. Therefore, we propose that improved manufacturing strategies for self-organized CNTs should consider both chemical and mechanical effects. This may be especially necessary to achieve high density CNT forests with low defect density, such as for improved thermal interfaces and high-permeability membranes. Electronic supplementary information (ESI) available: Detailed description of the cold-wall CVD reactor used for growing CNTs; fitting the diameter-dependent model-predicted CNT growth kinetics; time evolution of compressive stresses as a function of CNT diameter; time evolution of the diameter dependent variations in CNT number density; cumulative forest mass kinetics normalized to the number of CNTs. See DOI: 10.1039/c3nr34067h

  10. Blood sinuses in the submucosa of the large airways of the sheep.

    PubMed Central

    Hill, P; Goulding, D; Webber, S E; Widdicombe, J G

    1989-01-01

    We have studied the airway vasculature in sheep using light and transmission electron microscopy, as well as arterial and venous (retrograde) injections of anatomical corrosion compound and latex. Vascular casts were viewed by scanning electron microscopy. There is a complex network of blood sinuses of large diameter (up to 500 microns) in the submucosa of the large airways. The vessels have thin walls formed by a single layer of flattened endothelium with tight junctions and without pericytes or smooth muscle cells. Characteristically the sinuses lie between the cartilage and lamina propria of the trachea or between cartilage and smooth muscle in the bronchi. Sinuses of greater than 50 microns transverse diameter are not found in airways less than 1.0 mm across. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 7 PMID:2808119

  11. Effects of electric field on the maximum electro-spinning rate of silk fibroin solutions.

    PubMed

    Park, Bo Kyung; Um, In Chul

    2017-02-01

    Owing to the excellent cyto-compatibility of silk fibroin (SF) and the simple fabrication of nano-fibrous webs, electro-spun SF webs have attracted much research attention in numerous biomedical fields. Because the production rate of electro-spun webs is strongly dependent on the electro-spinning rate used, the electro-spinning rate becomes more important. In the present study, to improve the electro-spinning rate of SF solutions, various electric fields were applied during electro-spinning of SF, and its effects on the maximum electro-spinning rate of SF solution as well as diameters and molecular conformations of the electro-spun SF fibers were examined. As the electric field was increased, the maximum electro-spinning rate of the SF solution also increased. The maximum electro-spinning rate of a 13% SF solution could be increased 12×by increasing the electric field from 0.5kV/cm (0.25mL/h) to 2.5kV/cm (3.0mL/h). The dependence of the fiber diameter on the present electric field was not significant when using less-concentrated SF solutions (7-9% SF). On the other hand, at higher SF concentrations the electric field had a greater effect on the resulting fiber diameter. The electric field had a minimal effect of the molecular conformation and crystallinity index of the electro-spun SF webs. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Intradural Procedural Time to Assess Technical Difficulty of Superciliary Keyhole and Pterional Approaches for Unruptured Middle Cerebral Artery Aneurysms

    PubMed Central

    Choi, Yeon-Ju; Son, Wonsoo; Park, Ki-Su

    2016-01-01

    Objective This study used the intradural procedural time to assess the overall technical difficulty involved in surgically clipping an unruptured middle cerebral artery (MCA) aneurysm via a pterional or superciliary approach. The clinical and radiological variables affecting the intradural procedural time were investigated, and the intradural procedural time compared between a superciliary keyhole approach and a pterional approach. Methods During a 5.5-year period, patients with a single MCA aneurysm were enrolled in this retrospective study. The selection criteria for a superciliary keyhole approach included : 1) maximum diameter of the unruptured MCA aneurysm <15 mm, 2) neck diameter of the MCA aneurysm <10 mm, and 3) aneurysm location involving the sphenoidal or horizontal segment of MCA (M1) segment and MCA bifurcation, excluding aneurysms distal to the MCA genu. Meanwhile, the control comparison group included patients with the same selection criteria as for a superciliary approach, yet who preferred a pterional approach to avoid a postoperative facial wound or due to preoperative skin trouble in the supraorbital area. To determine the variables affecting the intradural procedural time, a multiple regression analysis was performed using such data as the patient age and gender, maximum aneurysm diameter, aneurysm neck diameter, and length of the pre-aneurysm M1 segment. In addition, the intradural procedural times were compared between the superciliary and pterional patient groups, along with the other variables. Results A total of 160 patients underwent a superciliary (n=124) or pterional (n=36) approach for an unruptured MCA aneurysm. In the multiple regression analysis, an increase in the diameter of the aneurysm neck (p<0.001) was identified as a statistically significant factor increasing the intradural procedural time. A Pearson correlation analysis also showed a positive correlation (r=0.340) between the neck diameter and the intradural procedural time. When comparing the superciliary and pterional groups, no statistically significant between-group difference was found in terms of the intradural procedural time reflecting the technical difficulty (mean±standard deviation : 29.8±13.0 min versus 27.7±9.6 min). Conclusion A superciliary keyhole approach can be a useful alternative to a pterional approach for an unruptured MCA aneurysm with a maximum diameter <15 mm and neck diameter <10 mm, representing no more of a technical challenge. For both surgical approaches, the technical difficulty increases along with the neck diameter of the MCA aneurysm. PMID:27847568

  13. Heat and fluid flow characteristics of an oval fin-and-tube heat exchanger with large diameters for textile machine dryer

    NASA Astrophysics Data System (ADS)

    Bae, Kyung Jin; Cha, Dong An; Kwon, Oh Kyung

    2016-11-01

    The objectives of this paper are to develop correlations between heat transfer and pressure drop for oval finned-tube heat exchanger with large diameters (larger than 20 mm) used in a textile machine dryer. Numerical tests using ANSYS CFX are performed for four different parameters; tube size, fin pitch, transverse tube pitch and longitudinal tube pitch. The numerical results showed that the Nusselt number and the friction factor are in a range of -16.2 ~ +3.1 to -7.7 ~ +3.9 %, respectively, compared with experimental results. It was found that the Nusselt number linearly increased with increasing Reynolds number, but the friction factor slightly decreased with increasing Reynolds number. It was also found that the variation of longitudinal tube pitch has little effect on the Nusselt number and friction factor than other parameters (below 2.0 and 2.5 %, respectively). This study proposed a new Nusselt number and friction factor correlation of the oval finned-tube heat exchanger with large diameters for textile machine dryer.

  14. Emergency Nightmares - Rupture of Type III Thoracoabdominal Aneurysm.

    PubMed

    Dias-Neto, Marina; Ramos, José Fernando; Rocha Neves, João; Almeida, Pedro; Rocha E Silva, Augusto; Teixeira, José Fernando

    2017-01-01

    Introduction The rupture of thoracoabdominal aneurysms (rTAA) represents one of the major challenges to the vascular surgeon. Recent developments in the endovascular armamentarium and the high mortality from open surgery make endovascular treatment an attractive option. Devices to be used in an emergency environment should be "off-the-shelf" and include, among others, EVAR snorkel/chimney and branched endoprosthesis (T-branch, Cook®). We describe the case of a 70-year-old patient who was admitted to the emergency room due continuous low back pain with 3 days of evolution. The tomographic computer angiography showed a type III thoracoabdominal aneurysm, with a transverse maximum diameter of 75x81mm in the infrarenal aorta and an exuberant hematoma in the left retroperitoneum, but no active extravasation of the contrast was observed (Figure 1). There was still marked tortuosity and moderate iliac calcification. It was decided to place a branched endoprosthesis (34 mm diameter at the top and 18 mm at the bottom). The branched endoprosthesis was extra-corporeally oriented, and introduced through a right femoral approach. The final position was verified with the digital subtraction angiography in anteroposterior incidence, ensuring that the distal border of each branch was 1.5 to 2 cm above the target vessel and that the stent marks presented the desired position. After the endoprosthesis was opened, the branches are catheterized by the left axillary access, however, it was verified that the endoprosthesis had an antero-posteriorly inverted implantation. It was possible to catheterize the superior mesenteric artery and the left renal artery (celiac trunk occlusion was documented intraoperatively); occlusion of the remaining endoprosthesis branches was performed with an Amplatzer. The patient evolved with multiorgan dysfunction and died at 24 hours post-operatively. Implantation of an off-the-shelf branched endoprosthesis requires specific anatomical criteria such as aortic diameter> 25mm to allow catheterization of the vessels, the possibility of incorporating each target vessel at a 90o angle in relation to each branch and visceral arteries with a diameter between 4 and 8 mm. Anatomy review is important to understand the lengths and positions of the branches. It should be borne in mind that it is possible that the device might have to be rotated during implantation to better align the marks and that both incidences (anteroposterior and profile) may be useful in confirming the position, something that should be thoroughly pursued to safeguard a correct implantation regardless of the initial stent position in your delivery system.

  15. Flexure fatigue testing of 90 deg graphite/epoxy composites

    NASA Technical Reports Server (NTRS)

    Peck, Ann Nancy W.

    1995-01-01

    A great deal of research has been performed characterizing the in-plane fiber-dominated properties, under both static and fatigue loading, of advanced composite materials. To the author's knowledge, no study has been performed to date investigating fatigue characteristics in the transverse direction. This information is important in the design of bonded composite airframe structure where repeated, cyclic out-of-plane bending may occur. Recent tests characterizing skin/stringer debond failures in reinforced composite panels where the dominant loading in the skin is flexure along the edge of the frame indicate failure initiated either in the skin or else the flange, near the flange tip. When failure initiated in the skin, transverse matrix cracks formed in the surface skin ply closest to the flange and either initiated delaminations or created matrix cracks in the next lower ply, which in turn initiated delaminations. When failure initiated in the flanges, transverse cracks formed in the flange angle ply closest to the skin and initiated delamination. In no configuration did failure propagate through the adhesive bond layer. For the examined skin/flange configurations, the maximum transverse tension stress at failure correlates very well with the transverse tension strength of the composites. Transverse tension strength (static) data of graphite epoxy composites have been shown to vary with the volume of material stressed. As the volume of material stressed increased, the strength decreased. A volumetric scaling law based on Weibull statistics can be used to predict the transverse strength measurements. The volume dependence reflects the presence of inherent flaws in the microstructure of the lamina. A similar approach may be taken to determine a volume scale effect on the transverse tension fatigue behavior of graphite/epoxy composites. The objective of this work is to generate transverse tension strength and fatigue S-N characteristics for composite materials using 3-point flexure tests of 90 deg graphite/epoxy specimens. Investigations will include the volume scale effect as well as frequency and span-to-thickness ratio effects. Prior to the start of the experimental study, an analytical study using finite element modeling will be performed to investigate the span-to-thickness effect. The ratio of transverse flexure stress to shear stress will be monitored and its values predicted by the FEM analysis compared with the value obtained using a 'strength of materials' based approach.

  16. The performance of the jet trigger for the ATLAS detector during 2011 data taking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aad, G.; Abbott, B.; Abdallah, J.

    The performance of the jet trigger for the ATLAS detector at the LHC during the 2011 data taking period is described. During 2011 the LHC provided proton–proton collisions with a centre-of-mass energy of 7 TeV and heavy ion collisions with a 2.76 TeV per nucleon–nucleon collision energy. The ATLAS trigger is a three level system designed to reduce the rate of events from the 40 MHz nominal maximum bunch crossing rate to the approximate 400 Hz which can be written to offline storage. The ATLAS jet trigger is the primary means for the online selection of events containing jets. Events are accepted by themore » trigger if they contain one or more jets above some transverse energy threshold. During 2011 data taking the jet trigger was fully efficient for jets with transverse energy above 25 GeV for triggers seeded randomly at Level 1. For triggers which require a jet to be identified at each of the three trigger levels, full efficiency is reached for offline jets with transverse energy above 60 GeV. Jets reconstructed in the final trigger level and corresponding to offline jets with transverse energy greater than 60 GeV, are reconstructed with a resolution in transverse energy with respect to offline jets, of better than 4 % in the central region and better than 2.5 % in the forward direction.« less

  17. The performance of the jet trigger for the ATLAS detector during 2011 data taking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aad, G.; Abbott, B.; Abdallah, J.

    The performance of the jet trigger for the ATLAS detector at the LHC during the 2011 data taking period is described. During 2011 the LHC provided proton–proton collisions with a centre-of-mass energy of 7 TeV and heavy ion collisions with a 2.76 TeV per nucleon–nucleon collision energy. The ATLAS trigger is a three level system designed to reduce the rate of events from the 40 MHz nominal maximum bunch crossing rate to the approximate 400 Hz which can be written to offline storage. The ATLAS jet trigger is the primary means for the online selection of events containing jets. Eventsmore » are accepted by the trigger if they contain one or more jets above some transverse energy threshold. During 2011 data taking the jet trigger was fully efficient for jets with transverse energy above 25 GeV for triggers seeded randomly at Level 1. For triggers which require a jet to be identified at each of the three trigger levels, full efficiency is reached for offline jets with transverse energy above 60 GeV. Jets reconstructed in the final trigger level and corresponding to offline jets with transverse energy greater than 60 GeV, are reconstructed with a resolution in transverse energy with respect to offline jets, of better than 4 % in the central region and better than 2.5 % in the forward direction.« less

  18. The performance of the jet trigger for the ATLAS detector during 2011 data taking

    DOE PAGES

    Aad, G.; Abbott, B.; Abdallah, J.; ...

    2016-09-27

    The performance of the jet trigger for the ATLAS detector at the LHC during the 2011 data taking period is described. During 2011 the LHC provided proton–proton collisions with a centre-of-mass energy of 7 TeV and heavy ion collisions with a 2.76 TeV per nucleon–nucleon collision energy. The ATLAS trigger is a three level system designed to reduce the rate of events from the 40 MHz nominal maximum bunch crossing rate to the approximate 400 Hz which can be written to offline storage. The ATLAS jet trigger is the primary means for the online selection of events containing jets. Events are accepted by themore » trigger if they contain one or more jets above some transverse energy threshold. During 2011 data taking the jet trigger was fully efficient for jets with transverse energy above 25 GeV for triggers seeded randomly at Level 1. For triggers which require a jet to be identified at each of the three trigger levels, full efficiency is reached for offline jets with transverse energy above 60 GeV. Jets reconstructed in the final trigger level and corresponding to offline jets with transverse energy greater than 60 GeV, are reconstructed with a resolution in transverse energy with respect to offline jets, of better than 4 % in the central region and better than 2.5 % in the forward direction.« less

  19. The performance of the jet trigger for the ATLAS detector during 2011 data taking.

    PubMed

    Aad, G; Abbott, B; Abdallah, J; Abdinov, O; Abeloos, B; Aben, R; Abolins, M; AbouZeid, O S; Abraham, N L; Abramowicz, H; Abreu, H; Abreu, R; Abulaiti, Y; Acharya, B S; Adamczyk, L; Adams, D L; Adelman, J; Adomeit, S; Adye, T; Affolder, A A; Agatonovic-Jovin, T; Agricola, J; Aguilar-Saavedra, J A; Ahlen, S P; Ahmadov, F; Aielli, G; Akerstedt, H; Åkesson, T P A; Akimov, A V; Alberghi, G L; Albert, J; Albrand, S; Verzini, M J Alconada; Aleksa, M; Aleksandrov, I N; Alexa, C; Alexander, G; Alexopoulos, T; Alhroob, M; Aliev, M; Alimonti, G; Alison, J; Alkire, S P; Allbrooke, B M M; Allen, B W; Allport, P P; Aloisio, A; Alonso, A; Alonso, F; Alpigiani, C; Gonzalez, B Alvarez; Piqueras, D Álvarez; Alviggi, M G; Amadio, B T; Amako, K; Coutinho, Y Amaral; Amelung, C; Amidei, D; Santos, S P Amor Dos; Amorim, A; Amoroso, S; Amram, N; Amundsen, G; Anastopoulos, C; Ancu, L S; Andari, N; Andeen, T; Anders, C F; Anders, G; Anders, J K; Anderson, K J; Andreazza, A; Andrei, V; Angelidakis, S; Angelozzi, I; Anger, P; Angerami, A; Anghinolfi, F; Anisenkov, A V; Anjos, N; Annovi, A; Antonelli, M; Antonov, A; Antos, J; Anulli, F; Aoki, M; Bella, L Aperio; Arabidze, G; Arai, Y; Araque, J P; Arce, A T H; Arduh, F A; Arguin, J-F; Argyropoulos, S; Arik, M; Armbruster, A J; Armitage, L J; Arnaez, O; Arnold, H; Arratia, M; Arslan, O; Artamonov, A; Artoni, G; Artz, S; Asai, S; Asbah, N; Ashkenazi, A; Åsman, B; Asquith, L; Assamagan, K; Astalos, R; Atkinson, M; Atlay, N B; Augsten, K; Avolio, G; Axen, B; Ayoub, M K; Azuelos, G; Baak, M A; Baas, A E; Baca, M J; Bachacou, H; Bachas, K; Backes, M; Backhaus, M; Bagiacchi, P; Bagnaia, P; Bai, Y; Baines, J T; Baker, O K; Baldin, E M; Balek, P; Balestri, T; Balli, F; Balunas, W K; Banas, E; Banerjee, Sw; Bannoura, A A E; Barak, L; Barberio, E L; Barberis, D; Barbero, M; Barillari, T; Barklow, T; Barlow, N; Barnes, S L; Barnett, B M; Barnett, R M; Barnovska, Z; Baroncelli, A; Barone, G; Barr, A J; Navarro, L Barranco; Barreiro, F; da Costa, J Barreiro Guimarães; Bartoldus, R; Barton, A E; Bartos, P; Basalaev, A; Bassalat, A; Basye, A; Bates, R L; Batista, S J; Batley, J R; Battaglia, M; Bauce, M; Bauer, F; Bawa, H S; Beacham, J B; Beattie, M D; Beau, T; Beauchemin, P H; Bechtle, P; Beck, H P; Becker, K; Becker, M; Beckingham, M; Becot, C; Beddall, A J; Beddall, A; Bednyakov, V A; Bedognetti, M; Bee, C P; Beemster, L J; Beermann, T A; Begel, M; Behr, J K; Belanger-Champagne, C; Bell, A S; Bella, G; Bellagamba, L; Bellerive, A; Bellomo, M; Belotskiy, K; Beltramello, O; Belyaev, N L; Benary, O; Benchekroun, D; Bender, M; Bendtz, K; Benekos, N; Benhammou, Y; Noccioli, E Benhar; Benitez, J; Garcia, J A Benitez; Benjamin, D P; Bensinger, J R; Bentvelsen, S; Beresford, L; Beretta, M; Berge, D; Kuutmann, E Bergeaas; Berger, N; Berghaus, F; Beringer, J; Berlendis, S; Bernard, N R; Bernius, C; Bernlochner, F U; Berry, T; Berta, P; Bertella, C; Bertoli, G; Bertolucci, F; Bertram, I A; Bertsche, C; Bertsche, D; Besjes, G J; Bylund, O Bessidskaia; Bessner, M; Besson, N; Betancourt, C; Bethke, S; Bevan, A J; Bhimji, W; Bianchi, R M; Bianchini, L; Bianco, M; Biebel, O; Biedermann, D; Bielski, R; Biesuz, N V; Biglietti, M; De Mendizabal, J Bilbao; Bilokon, H; Bindi, M; Binet, S; Bingul, A; Bini, C; Biondi, S; Bjergaard, D M; Black, C W; Black, J E; Black, K M; Blackburn, D; Blair, R E; Blanchard, J-B; Blanco, J E; Blazek, T; Bloch, I; Blocker, C; Blum, W; Blumenschein, U; Blunier, S; Bobbink, G J; Bobrovnikov, V S; Bocchetta, S S; Bocci, A; Bock, C; Boehler, M; Boerner, D; Bogaerts, J A; Bogavac, D; Bogdanchikov, A G; Bohm, C; Boisvert, V; Bold, T; Boldea, V; Boldyrev, A S; Bomben, M; Bona, M; Boonekamp, M; Borisov, A; Borissov, G; Bortfeldt, J; Bortoletto, D; Bortolotto, V; Bos, K; Boscherini, D; Bosman, M; Sola, J D Bossio; Boudreau, J; Bouffard, J; Bouhova-Thacker, E V; Boumediene, D; Bourdarios, C; Boutle, S K; Boveia, A; Boyd, J; Boyko, I R; Bracinik, J; Brandt, A; Brandt, G; Brandt, O; Bratzler, U; Brau, B; Brau, J E; Braun, H M; Madden, W D Breaden; Brendlinger, K; Brennan, A J; Brenner, L; Brenner, R; Bressler, S; Bristow, T M; Britton, D; Britzger, D; Brochu, F M; Brock, I; Brock, R; Brooijmans, G; Brooks, T; Brooks, W K; Brosamer, J; Brost, E; Broughton, J H; de Renstrom, P A Bruckman; Bruncko, D; Bruneliere, R; Bruni, A; Bruni, G; Brunt, B H; Bruschi, M; Bruscino, N; Bryant, P; Bryngemark, L; Buanes, T; Buat, Q; Buchholz, P; Buckley, A G; Budagov, I A; Buehrer, F; Bugge, M K; Bulekov, O; Bullock, D; Burckhart, H; Burdin, S; Burgard, C D; Burghgrave, B; Burka, K; Burke, S; Burmeister, I; Busato, E; Büscher, D; Büscher, V; Bussey, P; Butler, J M; Butt, A I; Buttar, C M; Butterworth, J M; Butti, P; Buttinger, W; Buzatu, A; Buzykaev, A R; Urbán, S Cabrera; Caforio, D; Cairo, V M; Cakir, O; Calace, N; Calafiura, P; Calandri, A; Calderini, G; Calfayan, P; Caloba, L P; Calvet, D; Calvet, S; Calvet, T P; Toro, R Camacho; Camarda, S; Camarri, P; Cameron, D; Armadans, R Caminal; Camincher, C; Campana, S; Campanelli, M; Campoverde, A; Canale, V; Canepa, A; Bret, M Cano; Cantero, J; Cantrill, R; Cao, T; Garrido, M D M Capeans; Caprini, I; Caprini, M; Capua, M; Caputo, R; Carbone, R M; Cardarelli, R; Cardillo, F; Carli, I; Carli, T; Carlino, G; Carminati, L; Caron, S; Carquin, E; Carrillo-Montoya, G D; Carter, J R; Carvalho, J; Casadei, D; Casado, M P; Casolino, M; Casper, D W; Castaneda-Miranda, E; Castelli, A; Gimenez, V Castillo; Castro, N F; Catinaccio, A; Catmore, J R; Cattai, A; Caudron, J; Cavaliere, V; Cavallaro, E; Cavalli, D; Cavalli-Sforza, M; Cavasinni, V; Ceradini, F; Alberich, L Cerda; Cerio, B C; Cerqueira, A S; Cerri, A; Cerrito, L; Cerutti, F; Cerv, M; Cervelli, A; Cetin, S A; Chafaq, A; Chakraborty, D; Chan, S K; Chan, Y L; Chang, P; Chapman, J D; Charlton, D G; Chatterjee, A; Chau, C C; Barajas, C A Chavez; Che, S; Cheatham, S; Chegwidden, A; Chekanov, S; Chekulaev, S V; Chelkov, G A; Chelstowska, M A; Chen, C; Chen, H; Chen, K; Chen, S; Chen, S; Chen, X; Chen, Y; Cheng, H C; Cheng, H J; Cheng, Y; Cheplakov, A; Cheremushkina, E; Moursli, R Cherkaoui El; Chernyatin, V; Cheu, E; Chevalier, L; Chiarella, V; Chiarelli, G; Chiodini, G; Chisholm, A S; Chitan, A; Chizhov, M V; Choi, K; Chomont, A R; Chouridou, S; Chow, B K B; Christodoulou, V; Chromek-Burckhart, D; Chudoba, J; Chuinard, A J; Chwastowski, J J; Chytka, L; Ciapetti, G; Ciftci, A K; Cinca, D; Cindro, V; Cioara, I A; Ciocio, A; Cirotto, F; Citron, Z H; Ciubancan, M; Clark, A; Clark, B L; Clark, M R; Clark, P J; Clarke, R N; Clement, C; Coadou, Y; Cobal, M; Coccaro, A; Cochran, J; Coffey, L; Colasurdo, L; Cole, B; Cole, S; Colijn, A P; Collot, J; Colombo, T; Compostella, G; Muiño, P Conde; Coniavitis, E; Connell, S H; Connelly, I A; Consorti, V; Constantinescu, S; Conta, C; Conti, G; Conventi, F; Cooke, M; Cooper, B D; Cooper-Sarkar, A M; Cornelissen, T; Corradi, M; Corriveau, F; Corso-Radu, A; Cortes-Gonzalez, A; Cortiana, G; Costa, G; Costa, M J; Costanzo, D; Cottin, G; Cowan, G; Cox, B E; Cranmer, K; Crawley, S J; Cree, G; Crépé-Renaudin, S; Crescioli, F; Cribbs, W A; Ortuzar, M Crispin; Cristinziani, M; Croft, V; Crosetti, G; Donszelmann, T Cuhadar; Cummings, J; Curatolo, M; Cúth, J; Cuthbert, C; Czirr, H; Czodrowski, P; D'Auria, S; D'Onofrio, M; De Sousa, M J Da Cunha Sargedas; Via, C Da; Dabrowski, W; Dai, T; Dale, O; Dallaire, F; Dallapiccola, C; Dam, M; Dandoy, J R; Dang, N P; Daniells, A C; Dann, N S; Danninger, M; Hoffmann, M Dano; Dao, V; Darbo, G; Darmora, S; Dassoulas, J; Dattagupta, A; Davey, W; David, C; Davidek, T; Davies, M; Davison, P; Davygora, Y; Dawe, E; Dawson, I; Daya-Ishmukhametova, R K; De, K; de Asmundis, R; De Benedetti, A; De Castro, S; De Cecco, S; De Groot, N; de Jong, P; De la Torre, H; De Lorenzi, F; De Pedis, D; De Salvo, A; De Sanctis, U; De Santo, A; De Regie, J B De Vivie; Dearnaley, W J; Debbe, R; Debenedetti, C; Dedovich, D V; Deigaard, I; Del Peso, J; Del Prete, T; Delgove, D; Deliot, F; Delitzsch, C M; Deliyergiyev, M; Dell'Acqua, A; Dell'Asta, L; Dell'Orso, M; Della Pietra, M; Della Volpe, D; Delmastro, M; Delsart, P A; Deluca, C; DeMarco, D A; Demers, S; Demichev, M; Demilly, A; Denisov, S P; Denysiuk, D; Derendarz, D; Derkaoui, J E; Derue, F; Dervan, P; Desch, K; Deterre, C; Dette, K; Deviveiros, P O; Dewhurst, A; Dhaliwal, S; Di Ciaccio, A; Di Ciaccio, L; Di Clemente, W K; Di Donato, C; Di Girolamo, A; Di Girolamo, B; Di Micco, B; Di Nardo, R; Di Simone, A; Di Sipio, R; Di Valentino, D; Diaconu, C; Diamond, M; Dias, F A; Diaz, M A; Diehl, E B; Dietrich, J; Diglio, S; Dimitrievska, A; Dingfelder, J; Dita, P; Dita, S; Dittus, F; Djama, F; Djobava, T; Djuvsland, J I; do Vale, M A B; Dobos, D; Dobre, M; Doglioni, C; Dohmae, T; Dolejsi, J; Dolezal, Z; Dolgoshein, B A; Donadelli, M; Donati, S; Dondero, P; Donini, J; Dopke, J; Doria, A; Dova, M T; Doyle, A T; Drechsler, E; Dris, M; Du, Y; Duarte-Campderros, J; Duchovni, E; Duckeck, G; Ducu, O A; Duda, D; Dudarev, A; Duflot, L; Duguid, L; Dührssen, M; Dunford, M; Yildiz, H Duran; Düren, M; Durglishvili, A; Duschinger, D; Dutta, B; Dyndal, M; Eckardt, C; Ecker, K M; Edgar, R C; Edson, W; Edwards, N C; Eifert, T; Eigen, G; Einsweiler, K; Ekelof, T; Kacimi, M El; Ellajosyula, V; Ellert, M; Elles, S; Ellinghaus, F; Elliot, A A; Ellis, N; Elmsheuser, J; Elsing, M; Emeliyanov, D; Enari, Y; Endner, O C; Endo, M; Ennis, J S; Erdmann, J; Ereditato, A; Ernis, G; Ernst, J; Ernst, M; Errede, S; Ertel, E; Escalier, M; Esch, H; Escobar, C; Esposito, B; Etienvre, A I; Etzion, E; Evans, H; Ezhilov, A; Fabbri, F; Fabbri, L; Facini, G; Fakhrutdinov, R M; Falciano, S; Falla, R J; Faltova, J; Fang, Y; Fanti, M; Farbin, A; Farilla, A; Farina, C; Farooque, T; Farrell, S; Farrington, S M; Farthouat, P; Fassi, F; Fassnacht, P; Fassouliotis, D; Giannelli, M Faucci; Favareto, A; Fawcett, W J; Fayard, L; Fedin, O L; Fedorko, W; Feigl, S; Feligioni, L; Feng, C; Feng, E J; Feng, H; Fenyuk, A B; Feremenga, L; Martinez, P Fernandez; Perez, S Fernandez; Ferrando, J; Ferrari, A; Ferrari, P; Ferrari, R; de Lima, D E Ferreira; Ferrer, A; Ferrere, D; Ferretti, C; Parodi, A Ferretto; Fiedler, F; Filipčič, A; Filipuzzi, M; Filthaut, F; Fincke-Keeler, M; Finelli, K D; Fiolhais, M C N; Fiorini, L; Firan, A; Fischer, A; Fischer, C; Fischer, J; Fisher, W C; Flaschel, N; Fleck, I; Fleischmann, P; Fletcher, G T; Fletcher, G; Fletcher, R R M; Flick, T; Floderus, A; Castillo, L R Flores; Flowerdew, M J; Forcolin, G T; Formica, A; Forti, A; Foster, A G; Fournier, D; Fox, H; Fracchia, S; Francavilla, P; Franchini, M; Francis, D; Franconi, L; Franklin, M; Frate, M; Fraternali, M; Freeborn, D; Fressard-Batraneanu, S M; Friedrich, F; Froidevaux, D; Frost, J A; Fukunaga, C; Torregrosa, E Fullana; Fusayasu, T; Fuster, J; Gabaldon, C; Gabizon, O; Gabrielli, A; Gabrielli, A; Gach, G P; Gadatsch, S; Gadomski, S; Gagliardi, G; Gagnon, L G; Gagnon, P; Galea, C; Galhardo, B; Gallas, E J; Gallop, B J; Gallus, P; Galster, G; Gan, K K; Gao, J; Gao, Y; Gao, Y S; Walls, F M Garay; García, C; Navarro, J E García; Garcia-Sciveres, M; Gardner, R W; Garelli, N; Garonne, V; Bravo, A Gascon; Gatti, C; Gaudiello, A; Gaudio, G; Gaur, B; Gauthier, L; Gavrilenko, I L; Gay, C; Gaycken, G; Gazis, E N; Gecse, Z; Gee, C N P; Geich-Gimbel, Ch; Geisler, M P; Gemme, C; Genest, M H; Geng, C; Gentile, S; George, S; Gerbaudo, D; Gershon, A; Ghasemi, S; Ghazlane, H; Ghneimat, M; Giacobbe, B; Giagu, S; Giannetti, P; Gibbard, B; Gibson, S M; Gignac, M; Gilchriese, M; Gillam, T P S; Gillberg, D; Gilles, G; Gingrich, D M; Giokaris, N; Giordani, M P; Giorgi, F M; Giorgi, F M; Giraud, P F; Giromini, P; Giugni, D; Giuli, F; Giuliani, C; Giulini, M; Gjelsten, B K; Gkaitatzis, S; Gkialas, I; Gkougkousis, E L; Gladilin, L K; Glasman, C; Glatzer, J; Glaysher, P C F; Glazov, A; Goblirsch-Kolb, M; Godlewski, J; Goldfarb, S; Golling, T; Golubkov, D; Gomes, A; Gonçalo, R; Costa, J Goncalves Pinto Firmino Da; Gonella, L; Gongadze, A; de la Hoz, S González; Parra, G Gonzalez; Gonzalez-Sevilla, S; Goossens, L; Gorbounov, P A; Gordon, H A; Gorelov, I; Gorini, B; Gorini, E; Gorišek, A; Gornicki, E; Goshaw, A T; Gössling, C; Gostkin, M I; Goudet, C R; Goujdami, D; Goussiou, A G; Govender, N; Gozani, E; Graber, L; Grabowska-Bold, I; Gradin, P O J; Grafström, P; Gramling, J; Gramstad, E; Grancagnolo, S; Gratchev, V; Gray, H M; Graziani, E; Greenwood, Z D; Grefe, C; Gregersen, K; Gregor, I M; Grenier, P; Grevtsov, K; Griffiths, J; Grillo, A A; Grimm, K; Grinstein, S; Gris, Ph; Grivaz, J-F; Groh, S; Grohs, J P; Gross, E; Grosse-Knetter, J; Grossi, G C; Grout, Z J; Guan, L; Guan, W; Guenther, J; Guescini, F; Guest, D; Gueta, O; Guido, E; Guillemin, T; Guindon, S; Gul, U; Gumpert, C; Guo, J; Guo, Y; Gupta, S; Gustavino, G; Gutierrez, P; Ortiz, N G Gutierrez; Gutschow, C; Guyot, C; Gwenlan, C; Gwilliam, C B; Haas, A; Haber, C; Hadavand, H K; Haddad, N; Hadef, A; Haefner, P; Hageböck, S; Hajduk, Z; Hakobyan, H; Haleem, M; Haley, J; Hall, D; Halladjian, G; Hallewell, G D; Hamacher, K; Hamal, P; Hamano, K; Hamilton, A; Hamity, G N; Hamnett, P G; Han, L; Hanagaki, K; Hanawa, K; Hance, M; Haney, B; Hanke, P; Hanna, R; Hansen, J B; Hansen, J D; Hansen, M C; Hansen, P H; Hara, K; Hard, A S; Harenberg, T; Hariri, F; Harkusha, S; Harrington, R D; Harrison, P F; Hartjes, F; Hasegawa, M; Hasegawa, Y; Hasib, A; Hassani, S; Haug, S; Hauser, R; Hauswald, L; Havranek, M; Hawkes, C M; Hawkings, R J; Hawkins, A D; Hayden, D; Hays, C P; Hays, J M; Hayward, H S; Haywood, S J; Head, S J; Heck, T; Hedberg, V; Heelan, L; Heim, S; Heim, T; Heinemann, B; Heinrich, J J; Heinrich, L; Heinz, C; Hejbal, J; Helary, L; Hellman, S; Helsens, C; Henderson, J; Henderson, R C W; Heng, Y; Henkelmann, S; Correia, A M Henriques; Henrot-Versille, S; Herbert, G H; Jiménez, Y Hernández; Herten, G; Hertenberger, R; Hervas, L; Hesketh, G G; Hessey, N P; Hetherly, J W; Hickling, R; Higón-Rodriguez, E; Hill, E; Hill, J C; Hiller, K H; Hillier, S J; Hinchliffe, I; Hines, E; Hinman, R R; Hirose, M; Hirschbuehl, D; Hobbs, J; Hod, N; Hodgkinson, M C; Hodgson, P; Hoecker, A; Hoeferkamp, M R; Hoenig, F; Hohlfeld, M; Hohn, D; Holmes, T R; Homann, M; Hong, T M; Hooberman, B H; Hopkins, W H; Horii, Y; Horton, A J; Hostachy, J-Y; Hou, S; Hoummada, A; Howard, J; Howarth, J; Hrabovsky, M; Hristova, I; Hrivnac, J; Hryn'ova, T; Hrynevich, A; Hsu, C; Hsu, P J; Hsu, S-C; Hu, D; Hu, Q; Huang, Y; Hubacek, Z; Hubaut, F; Huegging, F; Huffman, T B; Hughes, E W; Hughes, G; Huhtinen, M; Hülsing, T A; Huseynov, N; Huston, J; Huth, J; Iacobucci, G; Iakovidis, G; Ibragimov, I; Iconomidou-Fayard, L; Ideal, E; Idrissi, Z; Iengo, P; Igonkina, O; Iizawa, T; Ikegami, Y; Ikeno, M; Ilchenko, Y; Iliadis, D; Ilic, N; Ince, T; Introzzi, G; Ioannou, P; Iodice, M; Iordanidou, K; Ippolito, V; Quiles, A Irles; Isaksson, C; Ishino, M; Ishitsuka, M; Ishmukhametov, R; Issever, C; Istin, S; Ito, F; Ponce, J M Iturbe; Iuppa, R; Ivarsson, J; Iwanski, W; Iwasaki, H; Izen, J M; Izzo, V; Jabbar, S; Jackson, B; Jackson, M; Jackson, P; Jain, V; Jakobi, K B; Jakobs, K; Jakobsen, S; Jakoubek, T; Jamin, D O; Jana, D K; Jansen, E; Jansky, R; Janssen, J; Janus, M; Jarlskog, G; Javadov, N; Javůrek, T; Jeanneau, F; Jeanty, L; Jejelava, J; Jeng, G-Y; Jennens, D; Jenni, P; Jentzsch, J; Jeske, C; Jézéquel, S; Ji, H; Jia, J; Jiang, H; Jiang, Y; Jiggins, S; Pena, J Jimenez; Jin, S; Jinaru, A; Jinnouchi, O; Johansson, P; Johns, K A; Johnson, W J; Jon-And, K; Jones, G; Jones, R W L; Jones, S; Jones, T J; Jongmanns, J; Jorge, P M; Jovicevic, J; Ju, X; Rozas, A Juste; Köhler, M K; Kaczmarska, A; Kado, M; Kagan, H; Kagan, M; Kahn, S J; Kajomovitz, E; Kalderon, C W; Kaluza, A; Kama, S; Kamenshchikov, A; Kanaya, N; Kaneti, S; Kantserov, V A; Kanzaki, J; Kaplan, B; Kaplan, L S; Kapliy, A; Kar, D; Karakostas, K; Karamaoun, A; Karastathis, N; Kareem, M J; Karentzos, E; Karnevskiy, M; Karpov, S N; Karpova, Z M; Karthik, K; Kartvelishvili, V; Karyukhin, A N; Kasahara, K; Kashif, L; Kass, R D; Kastanas, A; Kataoka, Y; Kato, C; Katre, A; Katzy, J; Kawagoe, K; Kawamoto, T; Kawamura, G; Kazama, S; Kazanin, V F; Keeler, R; Kehoe, R; Keller, J S; Kempster, J J; Kentaro, K; Keoshkerian, H; Kepka, O; Kerševan, B P; Kersten, S; Keyes, R A; Khalil-Zada, F; Khandanyan, H; Khanov, A; Kharlamov, A G; Khoo, T J; Khovanskiy, V; Khramov, E; Khubua, J; Kido, S; Kim, H Y; Kim, S H; Kim, Y K; Kimura, N; Kind, O M; King, B T; King, M; King, S B; Kirk, J; Kiryunin, A E; Kishimoto, T; Kisielewska, D; Kiss, F; Kiuchi, K; Kivernyk, O; Kladiva, E; Klein, M H; Klein, M; Klein, U; Kleinknecht, K; Klimek, P; Klimentov, A; Klingenberg, R; Klinger, J A; Klioutchnikova, T; Kluge, E-E; Kluit, P; Kluth, S; Knapik, J; Kneringer, E; Knoops, E B F G; Knue, A; Kobayashi, A; Kobayashi, D; Kobayashi, T; Kobel, M; Kocian, M; Kodys, P; Koffas, T; Koffeman, E; Kogan, L A; Koi, T; Kolanoski, H; Kolb, M; Koletsou, I; Komar, A A; Komori, Y; Kondo, T; Kondrashova, N; Köneke, K; König, A C; Kono, T; Konoplich, R; Konstantinidis, N; Kopeliansky, R; Koperny, S; Köpke, L; Kopp, A K; Korcyl, K; Kordas, K; Korn, A; Korol, A A; Korolkov, I; Korolkova, E V; Kortner, O; Kortner, S; Kosek, T; Kostyukhin, V V; Kotwal, A; Kourkoumeli-Charalampidi, A; Kourkoumelis, C; Kouskoura, V; Koutsman, A; Kowalewska, A B; Kowalewski, R; Kowalski, T Z; Kozanecki, W; Kozhin, A S; Kramarenko, V A; Kramberger, G; Krasnopevtsev, D; Krasny, M W; Krasznahorkay, A; Kraus, J K; Kravchenko, A; Kretz, M; Kretzschmar, J; Kreutzfeldt, K; Krieger, P; Krizka, K; Kroeninger, K; Kroha, H; Kroll, J; Kroseberg, J; Krstic, J; Kruchonak, U; Krüger, H; Krumnack, N; Kruse, A; Kruse, M C; Kruskal, M; Kubota, T; Kucuk, H; Kuday, S; Kuechler, J T; Kuehn, S; Kugel, A; Kuger, F; Kuhl, A; Kuhl, T; Kukhtin, V; Kukla, R; Kulchitsky, Y; Kuleshov, S; Kuna, M; Kunigo, T; Kupco, A; Kurashige, H; Kurochkin, Y A; Kus, V; Kuwertz, E S; Kuze, M; Kvita, J; Kwan, T; Kyriazopoulos, D; Rosa, A La; Navarro, J L La Rosa; Rotonda, L La; Lacasta, C; Lacava, F; Lacey, J; Lacker, H; Lacour, D; Lacuesta, V R; Ladygin, E; Lafaye, R; Laforge, B; Lagouri, T; Lai, S; Lammers, S; Lampl, W; Lançon, E; Landgraf, U; Landon, M P J; Lang, V S; Lange, J C; Lankford, A J; Lanni, F; Lantzsch, K; Lanza, A; Laplace, S; Lapoire, C; Laporte, J F; Lari, T; Manghi, F Lasagni; Lassnig, M; Laurelli, P; Lavrijsen, W; Law, A T; Laycock, P; Lazovich, T; Lazzaroni, M; Dortz, O Le; Guirriec, E Le; Menedeu, E Le; Quilleuc, E P Le; LeBlanc, M; LeCompte, T; Ledroit-Guillon, F; Lee, C A; Lee, S C; Lee, L; Lefebvre, G; Lefebvre, M; Legger, F; Leggett, C; Lehan, A; Miotto, G Lehmann; Lei, X; Leight, W A; Leisos, A; Leister, A G; Leite, M A L; Leitner, R; Lellouch, D; Lemmer, B; Leney, K J C; Lenz, T; Lenzi, B; Leone, R; Leone, S; Leonidopoulos, C; Leontsinis, S; Lerner, G; Leroy, C; Lesage, A A J; Lester, C G; Levchenko, M; Levêque, J; Levin, D; Levinson, L J; Levy, M; Leyko, A M; Leyton, M; Li, B; Li, H; Li, H L; Li, L; Li, L; Li, Q; Li, S; Li, X; Li, Y; Liang, Z; Liao, H; Liberti, B; Liblong, A; Lichard, P; Lie, K; Liebal, J; Liebig, W; Limbach, C; Limosani, A; Lin, S C; Lin, T H; Lindquist, B E; Lipeles, E; Lipniacka, A; Lisovyi, M; Liss, T M; Lissauer, D; Lister, A; Litke, A M; Liu, B; Liu, D; Liu, H; Liu, H; Liu, J; Liu, J B; Liu, K; Liu, L; Liu, M; Liu, M; Liu, Y L; Liu, Y; Livan, M; Lleres, A; Merino, J Llorente; Lloyd, S L; Sterzo, F Lo; Lobodzinska, E; Loch, P; Lockman, W S; Loebinger, F K; Loevschall-Jensen, A E; Loew, K M; Loginov, A; Lohse, T; Lohwasser, K; Lokajicek, M; Long, B A; Long, J D; Long, R E; Longo, L; Looper, K A; Lopes, L; Mateos, D Lopez; Paredes, B Lopez; Paz, I Lopez; Solis, A Lopez; Lorenz, J; Martinez, N Lorenzo; Losada, M; Lösel, P J; Lou, X; Lounis, A; Love, J; Love, P A; Lu, H; Lu, N; Lubatti, H J; Luci, C; Lucotte, A; Luedtke, C; Luehring, F; Lukas, W; Luminari, L; Lundberg, O; Lund-Jensen, B; Lynn, D; Lysak, R; Lytken, E; Lyubushkin, V; Ma, H; Ma, L L; Ma, Y; Maccarrone, G; Macchiolo, A; Macdonald, C M; Maček, B; Miguens, J Machado; Madaffari, D; Madar, R; Maddocks, H J; Mader, W F; Madsen, A; Maeda, J; Maeland, S; Maeno, T; Maevskiy, A; Magradze, E; Mahlstedt, J; Maiani, C; Maidantchik, C; Maier, A A; Maier, T; Maio, A; Majewski, S; Makida, Y; Makovec, N; Malaescu, B; Malecki, Pa; Maleev, V P; Malek, F; Mallik, U; Malon, D; Malone, C; Maltezos, S; Malyukov, S; Mamuzic, J; Mancini, G; Mandelli, B; Mandelli, L; Mandić, I; Maneira, J; Filho, L Manhaes de Andrade; Ramos, J Manjarres; Mann, A; Mansoulie, B; Mantifel, R; Mantoani, M; Manzoni, S; Mapelli, L; Marceca, G; March, L; Marchiori, G; Marcisovsky, M; Marjanovic, M; Marley, D E; Marroquim, F; Marsden, S P; Marshall, Z; Marti, L F; Marti-Garcia, S; Martin, B; Martin, T A; Martin, V J; Latour, B Martin Dit; Martinez, M; Martin-Haugh, S; Martoiu, V S; Martyniuk, A C; Marx, M; Marzano, F; Marzin, A; Masetti, L; Mashimo, T; Mashinistov, R; Masik, J; Maslennikov, A L; Massa, I; Massa, L; Mastrandrea, P; Mastroberardino, A; Masubuchi, T; Mättig, P; Mattmann, J; Maurer, J; Maxfield, S J; Maximov, D A; Mazini, R; Mazza, S M; Fadden, N C Mc; Goldrick, G Mc; Kee, S P Mc; McCarn, A; McCarthy, R L; McCarthy, T G; McClymont, L I; McFarlane, K W; Mcfayden, J A; Mchedlidze, G; McMahon, S J; McPherson, R A; Medinnis, M; Meehan, S; Mehlhase, S; Mehta, A; Meier, K; Meineck, C; Meirose, B; Garcia, B R Mellado; Meloni, F; Mengarelli, A; Menke, S; Meoni, E; Mercurio, K M; Mergelmeyer, S; Mermod, P; Merola, L; Meroni, C; Merritt, F S; Messina, A; Metcalfe, J; Mete, A S; Meyer, C; Meyer, C; Meyer, J-P; Meyer, J; Theenhausen, H Meyer Zu; Middleton, R P; Miglioranzi, S; Mijović, L; Mikenberg, G; Mikestikova, M; Mikuž, M; Milesi, M; Milic, A; Miller, D W; Mills, C; Milov, A; Milstead, D A; Minaenko, A A; Minami, Y; Minashvili, I A; Mincer, A I; Mindur, B; Mineev, M; Ming, Y; Mir, L M; Mistry, K P; Mitani, T; Mitrevski, J; Mitsou, V A; Miucci, A; Miyagawa, P S; Mjörnmark, J U; Moa, T; Mochizuki, K; Mohapatra, S; Mohr, W; Molander, S; Moles-Valls, R; Monden, R; Mondragon, M C; Mönig, K; Monk, J; Monnier, E; Montalbano, A; Berlingen, J Montejo; Monticelli, F; Monzani, S; Moore, R W; Morange, N; Moreno, D; Llácer, M Moreno; Morettini, P; Mori, D; Mori, T; Morii, M; Morinaga, M; Morisbak, V; Moritz, S; Morley, A K; Mornacchi, G; Morris, J D; Mortensen, S S; Morvaj, L; Mosidze, M; Moss, J; Motohashi, K; Mount, R; Mountricha, E; Mouraviev, S V; Moyse, E J W; Muanza, S; Mudd, R D; Mueller, F; Mueller, J; Mueller, R S P; Mueller, T; Muenstermann, D; Mullen, P; Mullier, G A; Sanchez, F J Munoz; Quijada, J A Murillo; Murray, W J; Musheghyan, H; Muškinja, M; Myagkov, A G; Myska, M; Nachman, B P; Nackenhorst, O; Nadal, J; Nagai, K; Nagai, R; Nagano, K; Nagasaka, Y; Nagata, K; Nagel, M; Nagy, E; Nairz, A M; Nakahama, Y; Nakamura, K; Nakamura, T; Nakano, I; Namasivayam, H; Garcia, R F Naranjo; Narayan, R; Villar, D I Narrias; Naryshkin, I; Naumann, T; Navarro, G; Nayyar, R; Neal, H A; Nechaeva, P Yu; Neep, T J; Nef, P D; Negri, A; Negrini, M; Nektarijevic, S; Nellist, C; Nelson, A; Nemecek, S; Nemethy, P; Nepomuceno, A A; Nessi, M; Neubauer, M S; Neumann, M; Neves, R M; Nevski, P; Newman, P R; Nguyen, D H; Nickerson, R B; Nicolaidou, R; Nicquevert, B; Nielsen, J; Nikiforov, A; Nikolaenko, V; Nikolic-Audit, I; Nikolopoulos, K; Nilsen, J K; Nilsson, P; Ninomiya, Y; Nisati, A; Nisius, R; Nobe, T; Nodulman, L; Nomachi, M; Nomidis, I; Nooney, T; Norberg, S; Nordberg, M; Norjoharuddeen, N; Novgorodova, O; Nowak, S; Nozaki, M; Nozka, L; Ntekas, K; Nurse, E; Nuti, F; O'grady, F; O'Neil, D C; O'Rourke, A A; O'Shea, V; Oakham, F G; Oberlack, H; Obermann, T; Ocariz, J; Ochi, A; Ochoa, I; Ochoa-Ricoux, J P; Oda, S; Odaka, S; Ogren, H; Oh, A; Oh, S H; Ohm, C C; Ohman, H; Oide, H; Okawa, H; Okumura, Y; Okuyama, T; Olariu, A; Seabra, L F Oleiro; Pino, S A Olivares; Damazio, D Oliveira; Olszewski, A; Olszowska, J; Onofre, A; Onogi, K; Onyisi, P U E; Oram, C J; Oreglia, M J; Oren, Y; Orestano, D; Orlando, N; Orr, R S; Osculati, B; Ospanov, R; Garzon, G Otero Y; Otono, H; Ouchrif, M; Ould-Saada, F; Ouraou, A; Oussoren, K P; Ouyang, Q; Ovcharova, A; Owen, M; Owen, R E; Ozcan, V E; Ozturk, N; Pachal, K; Pages, A Pacheco; Aranda, C Padilla; Pagáčová, M; Griso, S Pagan; Paige, F; Pais, P; Pajchel, K; Palacino, G; Palestini, S; Palka, M; Pallin, D; Palma, A; Panagiotopoulou, E St; Pandini, C E; Vazquez, J G Panduro; Pani, P; Panitkin, S; Pantea, D; Paolozzi, L; Papadopoulou, Th D; Papageorgiou, K; Paramonov, A; Hernandez, D Paredes; Parker, A J; Parker, M A; Parker, K A; Parodi, F; Parsons, J A; Parzefall, U; Pascuzzi, V R; Pasqualucci, E; Passaggio, S; Pastore, F; Pastore, Fr; Pásztor, G; Pataraia, S; Patel, N D; Pater, J R; Pauly, T; Pearce, J; Pearson, B; Pedersen, L E; Pedersen, M; Lopez, S Pedraza; Pedro, R; Peleganchuk, S V; Pelikan, D; Penc, O; Peng, C; Peng, H; Penwell, J; Peralva, B S; Perego, M M; Perepelitsa, D V; Codina, E Perez; Perini, L; Pernegger, H; Perrella, S; Peschke, R; Peshekhonov, V D; Peters, K; Peters, R F Y; Petersen, B A; Petersen, T C; Petit, E; Petridis, A; Petridou, C; Petroff, P; Petrolo, E; Petrov, M; Petrucci, F; Pettersson, N E; Peyaud, A; Pezoa, R; Phillips, P W; Piacquadio, G; Pianori, E; Picazio, A; Piccaro, E; Piccinini, M; Pickering, M A; Piegaia, R; Pilcher, J E; Pilkington, A D; Pin, A W J; Pina, J; Pinamonti, M; Pinfold, J L; Pingel, A; Pires, S; Pirumov, H; Pitt, M; Plazak, L; Pleier, M-A; Pleskot, V; Plotnikova, E; Plucinski, P; Pluth, D; Poettgen, R; Poggioli, L; Pohl, D; Polesello, G; Poley, A; Policicchio, A; Polifka, R; Polini, A; Pollard, C S; Polychronakos, V; Pommès, K; Pontecorvo, L; Pope, B G; Popeneciu, G A; Popovic, D S; Poppleton, A; Pospisil, S; Potamianos, K; Potrap, I N; Potter, C J; Potter, C T; Poulard, G; Poveda, J; Pozdnyakov, V; Astigarraga, M E Pozo; Pralavorio, P; Pranko, A; Prell, S; Price, D; Price, L E; Primavera, M; Prince, S; Proissl, M; Prokofiev, K; Prokoshin, F; Protopopescu, S; Proudfoot, J; Przybycien, M; Puddu, D; Puldon, D; Purohit, M; Puzo, P; Qian, J; Qin, G; Qin, Y; Quadt, A; Quayle, W B; Queitsch-Maitland, M; Quilty, D; Raddum, S; Radeka, V; Radescu, V; Radhakrishnan, S K; Radloff, P; Rados, P; Ragusa, F; Rahal, G; Raine, J A; Rajagopalan, S; Rammensee, M; Rangel-Smith, C; Ratti, M G; Rauscher, F; Rave, S; Ravenscroft, T; Raymond, M; Read, A L; Readioff, N P; Rebuzzi, D M; Redelbach, A; Redlinger, G; Reece, R; Reeves, K; Rehnisch, L; Reichert, J; Reisin, H; Rembser, C; Ren, H; Rescigno, M; Resconi, S; Rezanova, O L; Reznicek, P; Rezvani, R; Richter, R; Richter, S; Richter-Was, E; Ricken, O; Ridel, M; Rieck, P; Riegel, C J; Rieger, J; Rifki, O; Rijssenbeek, M; Rimoldi, A; Rinaldi, L; Ristić, B; Ritsch, E; Riu, I; Rizatdinova, F; Rizvi, E; Rizzi, C; Robertson, S H; Robichaud-Veronneau, A; Robinson, D; Robinson, J E M; Robson, A; Roda, C; Rodina, Y; Perez, A Rodriguez; Rodriguez, D Rodriguez; Roe, S; Rogan, C S; Røhne, O; Romaniouk, A; Romano, M; Saez, S M Romano; Adam, E Romero; Rompotis, N; Ronzani, M; Roos, L; Ros, E; Rosati, S; Rosbach, K; Rose, P; Rosenthal, O; Rossetti, V; Rossi, E; Rossi, L P; Rosten, J H N; Rosten, R; Rotaru, M; Roth, I; Rothberg, J; Rousseau, D; Royon, C R; Rozanov, A; Rozen, Y; Ruan, X; Rubbo, F; Rubinskiy, I; Rud, V I; Rudolph, M S; Rühr, F; Ruiz-Martinez, A; Rurikova, Z; Rusakovich, N A; Ruschke, A; Russell, H L; Rutherfoord, J P; Ruthmann, N; Ryabov, Y F; Rybar, M; Rybkin, G; Ryu, S; Ryzhov, A; Saavedra, A F; Sabato, G; Sacerdoti, S; Sadrozinski, H F-W; Sadykov, R; Tehrani, F Safai; Saha, P; Sahinsoy, M; Saimpert, M; Saito, T; Sakamoto, H; Sakurai, Y; Salamanna, G; Salamon, A; Loyola, J E Salazar; Salek, D; De Bruin, P H Sales; Salihagic, D; Salnikov, A; Salt, J; Salvatore, D; Salvatore, F; Salvucci, A; Salzburger, A; Sammel, D; Sampsonidis, D; Sanchez, A; Sánchez, J; Martinez, V Sanchez; Sandaker, H; Sandbach, R L; Sander, H G; Sanders, M P; Sandhoff, M; Sandoval, C; Sandstroem, R; Sankey, D P C; Sannino, M; Sansoni, A; Santoni, C; Santonico, R; Santos, H; Castillo, I Santoyo; Sapp, K; Sapronov, A; Saraiva, J G; Sarrazin, B; Sasaki, O; Sasaki, Y; Sato, K; Sauvage, G; Sauvan, E; Savage, G; Savard, P; Sawyer, C; Sawyer, L; Saxon, J; Sbarra, C; Sbrizzi, A; Scanlon, T; Scannicchio, D A; Scarcella, M; Scarfone, V; Schaarschmidt, J; Schacht, P; Schaefer, D; Schaefer, R; Schaeffer, J; Schaepe, S; Schaetzel, S; Schäfer, U; Schaffer, A C; Schaile, D; Schamberger, R D; Scharf, V; Schegelsky, V A; Scheirich, D; Schernau, M; Schiavi, C; Schillo, C; Schioppa, M; Schlenker, S; Schmieden, K; Schmitt, C; Schmitt, S; Schmitz, S; Schneider, B; Schnellbach, Y J; Schnoor, U; Schoeffel, L; Schoening, A; Schoenrock, B D; Schopf, E; Schorlemmer, A L S; Schott, M; Schovancova, J; Schramm, S; Schreyer, M; Schuh, N; Schultens, M J; Schultz-Coulon, H-C; Schulz, H; Schumacher, M; Schumm, B A; Schune, Ph; Schwanenberger, C; Schwartzman, A; Schwarz, T A; Schwegler, Ph; Schweiger, H; Schwemling, Ph; Schwienhorst, R; Schwindling, J; Schwindt, T; Sciolla, G; Scuri, F; Scutti, F; Searcy, J; Seema, P; Seidel, S C; Seiden, A; Seifert, F; Seixas, J M; Sekhniaidze, G; Sekhon, K; Sekula, S J; Seliverstov, D M; Semprini-Cesari, N; Serfon, C; Serin, L; Serkin, L; Sessa, M; Seuster, R; Severini, H; Sfiligoj, T; Sforza, F; Sfyrla, A; Shabalina, E; Shaikh, N W; Shan, L Y; Shang, R; Shank, J T; Shapiro, M; Shatalov, P B; Shaw, K; Shaw, S M; Shcherbakova, A; Shehu, C Y; Sherwood, P; Shi, L; Shimizu, S; Shimmin, C O; Shimojima, M; Shiyakova, M; Shmeleva, A; Saadi, D Shoaleh; Shochet, M J; Shojaii, S; Shrestha, S; Shulga, E; Shupe, M A; Sicho, P; Sidebo, P E; Sidiropoulou, O; Sidorov, D; Sidoti, A; Siegert, F; Sijacki, Dj; Silva, J; Silverstein, S B; Simak, V; Simard, O; Simic, Lj; Simion, S; Simioni, E; Simmons, B; Simon, D; Simon, M; Sinervo, P; Sinev, N B; Sioli, M; Siragusa, G; Sivoklokov, S Yu; Sjölin, J; Sjursen, T B; Skinner, M B; Skottowe, H P; Skubic, P; Slater, M; Slavicek, T; Slawinska, M; Sliwa, K; Slovak, R; Smakhtin, V; Smart, B H; Smestad, L; Smirnov, S Yu; Smirnov, Y; Smirnova, L N; Smirnova, O; Smith, M N K; Smith, R W; Smizanska, M; Smolek, K; Snesarev, A A; Snidero, G; Snyder, S; Sobie, R; Socher, F; Soffer, A; Soh, D A; Sokhrannyi, G; Sanchez, C A Solans; Solar, M; Soldatov, E Yu; Soldevila, U; Solodkov, A A; Soloshenko, A; Solovyanov, O V; Solovyev, V; Sommer, P; Son, H; Song, H Y; Sood, A; Sopczak, A; Sopko, V; Sorin, V; Sosa, D; Sotiropoulou, C L; Soualah, R; Soukharev, A M; South, D; Sowden, B C; Spagnolo, S; Spalla, M; Spangenberg, M; Spanò, F; Sperlich, D; Spettel, F; Spighi, R; Spigo, G; Spiller, L A; Spousta, M; Denis, R D St; Stabile, A; Stahlman, J; Stamen, R; Stamm, S; Stanecka, E; Stanek, R W; Stanescu, C; Stanescu-Bellu, M; Stanitzki, M M; Stapnes, S; Starchenko, E A; Stark, G H; Stark, J; Staroba, P; Starovoitov, P; Stärz, S; Staszewski, R; Steinberg, P; Stelzer, B; Stelzer, H J; Stelzer-Chilton, O; Stenzel, H; Stewart, G A; Stillings, J A; Stockton, M C; Stoebe, M; Stoicea, G; Stolte, P; Stonjek, S; Stradling, A R; Straessner, A; Stramaglia, M E; Strandberg, J; Strandberg, S; Strandlie, A; Strauss, M; Strizenec, P; Ströhmer, R; Strom, D M; Stroynowski, R; Strubig, A; Stucci, S A; Stugu, B; Styles, N A; Su, D; Su, J; Subramaniam, R; Suchek, S; Sugaya, Y; Suk, M; Sulin, V V; Sultansoy, S; Sumida, T; Sun, S; Sun, X; Sundermann, J E; Suruliz, K; Susinno, G; Sutton, M R; Suzuki, S; Svatos, M; Swiatlowski, M; Sykora, I; Sykora, T; Ta, D; Taccini, C; Tackmann, K; Taenzer, J; Taffard, A; Tafirout, R; Taiblum, N; Takai, H; Takashima, R; Takeda, H; Takeshita, T; Takubo, Y; Talby, M; Talyshev, A A; Tam, J Y C; Tan, K G; Tanaka, J; Tanaka, R; Tanaka, S; Tannenwald, B B; Araya, S Tapia; Tapprogge, S; Tarem, S; Tartarelli, G F; Tas, P; Tasevsky, M; Tashiro, T; Tassi, E; Delgado, A Tavares; Tayalati, Y; Taylor, A C; Taylor, G N; Taylor, P T E; Taylor, W; Teischinger, F A; Teixeira-Dias, P; Temming, K K; Temple, D; Kate, H Ten; Teng, P K; Teoh, J J; Tepel, F; Terada, S; Terashi, K; Terron, J; Terzo, S; Testa, M; Teuscher, R J; Theveneaux-Pelzer, T; Thomas, J P; Thomas-Wilsker, J; Thompson, E N; Thompson, P D; Thompson, R J; Thompson, A S; Thomsen, L A; Thomson, E; Thomson, M; Tibbetts, M J; Torres, R E Ticse; Tikhomirov, V O; Tikhonov, Yu A; Timoshenko, S; Tipton, P; Tisserant, S; Todome, K; Todorov, T; Todorova-Nova, S; Tojo, J; Tokár, S; Tokushuku, K; Tolley, E; Tomlinson, L; Tomoto, M; Tompkins, L; Toms, K; Tong, B; Torrence, E; Torres, H; Pastor, E Torró; Toth, J; Touchard, F; Tovey, D R; Trefzger, T; Tricoli, A; Trigger, I M; Trincaz-Duvoid, S; Tripiana, M F; Trischuk, W; Trocmé, B; Trofymov, A; Troncon, C; Trottier-McDonald, M; Trovatelli, M; Truong, L; Trzebinski, M; Trzupek, A; Tseng, J C-L; Tsiareshka, P V; Tsipolitis, G; Tsirintanis, N; Tsiskaridze, S; Tsiskaridze, V; Tskhadadze, E G; Tsui, K M; Tsukerman, I I; Tsulaia, V; Tsuno, S; Tsybychev, D; Tudorache, A; Tudorache, V; Tuna, A N; Tupputi, S A; Turchikhin, S; Turecek, D; Turgeman, D; Turra, R; Turvey, A J; Tuts, P M; Tyndel, M; Ucchielli, G; Ueda, I; Ueno, R; Ughetto, M; Ukegawa, F; Unal, G; Undrus, A; Unel, G; Ungaro, F C; Unno, Y; Unverdorben, C; Urban, J; Urquijo, P; Urrejola, P; Usai, G; Usanova, A; Vacavant, L; Vacek, V; Vachon, B; Valderanis, C; Santurio, E Valdes; Valencic, N; Valentinetti, S; Valero, A; Valery, L; Valkar, S; Vallecorsa, S; Ferrer, J A Valls; Van Den Wollenberg, W; Van Der Deijl, P C; van der Geer, R; van der Graaf, H; van Eldik, N; van Gemmeren, P; Van Nieuwkoop, J; van Vulpen, I; van Woerden, M C; Vanadia, M; Vandelli, W; Vanguri, R; Vaniachine, A; Vankov, P; Vardanyan, G; Vari, R; Varnes, E W; Varol, T; Varouchas, D; Vartapetian, A; Varvell, K E; Vasquez, J G; Vazeille, F; Schroeder, T Vazquez; Veatch, J; Veloce, L M; Veloso, F; Veneziano, S; Ventura, A; Venturi, M; Venturi, N; Venturini, A; Vercesi, V; Verducci, M; Verkerke, W; Vermeulen, J C; Vest, A; Vetterli, M C; Viazlo, O; Vichou, I; Vickey, T; Boeriu, O E Vickey; Viehhauser, G H A; Viel, S; Vigani, L; Vigne, R; Villa, M; Perez, M Villaplana; Vilucchi, E; Vincter, M G; Vinogradov, V B; Vittori, C; Vivarelli, I; Vlachos, S; Vlasak, M; Vogel, M; Vokac, P; Volpi, G; Volpi, M; von der Schmitt, H; von Toerne, E; Vorobel, V; Vorobev, K; Vos, M; Voss, R; Vossebeld, J H; Vranjes, N; Milosavljevic, M Vranjes; Vrba, V; Vreeswijk, M; Vuillermet, R; Vukotic, I; Vykydal, Z; Wagner, P; Wagner, W; Wahlberg, H; Wahrmund, S; Wakabayashi, J; Walder, J; Walker, R; Walkowiak, W; Wallangen, V; Wang, C; Wang, C; Wang, F; Wang, H; Wang, H; Wang, J; Wang, J; Wang, K; Wang, R; Wang, S M; Wang, T; Wang, T; Wang, X; Wanotayaroj, C; Warburton, A; Ward, C P; Wardrope, D R; Washbrook, A; Watkins, P M; Watson, A T; Watson, I J; Watson, M F; Watts, G; Watts, S; Waugh, B M; Webb, S; Weber, M S; Weber, S W; Webster, J S; Weidberg, A R; Weinert, B; Weingarten, J; Weiser, C; Weits, H; Wells, P S; Wenaus, T; Wengler, T; Wenig, S; Wermes, N; Werner, M; Werner, P; Wessels, M; Wetter, J; Whalen, K; Whallon, N L; Wharton, A M; White, A; White, M J; White, R; White, S; Whiteson, D; Wickens, F J; Wiedenmann, W; Wielers, M; Wienemann, P; Wiglesworth, C; Wiik-Fuchs, L A M; Wildauer, A; Wilk, F; Wilkens, H G; Williams, H H; Williams, S; Willis, C; Willocq, S; Wilson, J A; Wingerter-Seez, I; Winklmeier, F; Winston, O J; Winter, B T; Wittgen, M; Wittkowski, J; Wollstadt, S J; Wolter, M W; Wolters, H; Wosiek, B K; Wotschack, J; Woudstra, M J; Wozniak, K W; Wu, M; Wu, M; Wu, S L; Wu, X; Wu, Y; Wyatt, T R; Wynne, B M; Xella, S; Xu, D; Xu, L; Yabsley, B; Yacoob, S; Yakabe, R; Yamaguchi, D; Yamaguchi, Y; Yamamoto, A; Yamamoto, S; Yamanaka, T; Yamauchi, K; Yamazaki, Y; Yan, Z; Yang, H; Yang, H; Yang, Y; Yang, Z; Yao, W-M; Yap, Y C; Yasu, Y; Yatsenko, E; Wong, K H Yau; Ye, J; Ye, S; Yeletskikh, I; Yen, A L; Yildirim, E; Yorita, K; Yoshida, R; Yoshihara, K; Young, C; Young, C J S; Youssef, S; Yu, D R; Yu, J; Yu, J M; Yu, J; Yuan, L; Yuen, S P Y; Yusuff, I; Zabinski, B; Zaidan, R; Zaitsev, A M; Zakharchuk, N; Zalieckas, J; Zaman, A; Zambito, S; Zanello, L; Zanzi, D; Zeitnitz, C; Zeman, M; Zemla, A; Zeng, J C; Zeng, Q; Zengel, K; Zenin, O; Ženiš, T; Zerwas, D; Zhang, D; Zhang, F; Zhang, G; Zhang, H; Zhang, J; Zhang, L; Zhang, R; Zhang, R; Zhang, X; Zhang, Z; Zhao, X; Zhao, Y; Zhao, Z; Zhemchugov, A; Zhong, J; Zhou, B; Zhou, C; Zhou, L; Zhou, L; Zhou, M; Zhou, N; Zhu, C G; Zhu, H; Zhu, J; Zhu, Y; Zhuang, X; Zhukov, K; Zibell, A; Zieminska, D; Zimine, N I; Zimmermann, C; Zimmermann, S; Zinonos, Z; Zinser, M; Ziolkowski, M; Živković, L; Zobernig, G; Zoccoli, A; Nedden, M Zur; Zurzolo, G; Zwalinski, L

    2016-01-01

    The performance of the jet trigger for the ATLAS detector at the LHC during the 2011 data taking period is described. During 2011 the LHC provided proton-proton collisions with a centre-of-mass energy of 7 TeV and heavy ion collisions with a 2.76 TeV per nucleon-nucleon collision energy. The ATLAS trigger is a three level system designed to reduce the rate of events from the 40 MHz nominal maximum bunch crossing rate to the approximate 400 Hz which can be written to offline storage. The ATLAS jet trigger is the primary means for the online selection of events containing jets. Events are accepted by the trigger if they contain one or more jets above some transverse energy threshold. During 2011 data taking the jet trigger was fully efficient for jets with transverse energy above 25 GeV for triggers seeded randomly at Level 1. For triggers which require a jet to be identified at each of the three trigger levels, full efficiency is reached for offline jets with transverse energy above 60 GeV. Jets reconstructed in the final trigger level and corresponding to offline jets with transverse energy greater than 60 GeV, are reconstructed with a resolution in transverse energy with respect to offline jets, of better than 4 % in the central region and better than 2.5 % in the forward direction.

  20. Central obesity is an independent predictor of erectile dysfunction in older men.

    PubMed

    Riedner, Charles Edison; Rhoden, Ernani Luis; Ribeiro, Eduardo Porto; Fuchs, Sandra Costa

    2006-10-01

    There is a growing body of evidence in the literature correlating erectile dysfunction to obesity. We investigated the correlation of different anthropometric indexes of central obesity to erectile dysfunction. A cross-sectional study was performed including 256 consecutive men 40 years old or older. All men completed the International Index of Erectile Function, and were evaluated routinely with a clinical history, physical examination and blood analysis for fasting serum glucose, lipid profile and serum testosterone. Anthropometric measures included body mass index, waist circumference, sagittal abdominal diameter, maximal abdominal circumference, and waist-hip, waist-thigh, waist-height, sagittal abdominal diameter-thigh and sagittal abdominal diameter-height indexes. In men 40 to 60 years old the different anthropometric indexes of central obesity were not correlated with the presence of erectile dysfunction (p > 0.05). Men older than 60 years (41%, range 61 to 81) demonstrated an association among erectile dysfunction and waist-hip index (p = 0.04), waist-thigh index (p = 0.02), sagittal abdominal diameter (p = 0.03), sagittal abdominal diameter-height index (p = 0.02) and maximal abdominal circumference (p = 0.04). After logistic regression analysis an independent effect on the presence of erectile dysfunction was observed for waist-hip index (OR 8.56, 95% CI 1.44-50.73), sagittal abdominal diameter (OR 7.87, 95% CI 1.24-49.75), sagittal abdominal diameter-height index (OR 14.21, 95% CI 1.11-182.32), maximum abdominal circumference (OR 11.72, 95% CI 1.73-79.18) and waist circumference (OR 19.37, 95% CI 1.15-326.55). This study suggests that central obesity, assessed by several anthropometric indicators, is associated to the presence of erectile dysfunction in men older than 60 years. Sagittal abdominal diameter, sagittal abdominal diameter-height index, maximum abdominal circumference, waist circumference and waist-hip index were useful indicators to predict the presence of erectile dysfunction.

  1. Photon Counting Detectors for the 1.0 - 2.0 Micron Wavelength Range

    NASA Technical Reports Server (NTRS)

    Krainak, Michael A.

    2004-01-01

    We describe results on the development of greater than 200 micron diameter, single-element photon-counting detectors for the 1-2 micron wavelength range. The technical goals include quantum efficiency in the range 10-70%; detector diameter greater than 200 microns; dark count rate below 100 kilo counts-per-second (cps), and maximum count rate above 10 Mcps.

  2. 76 FR 26280 - Vermont Marble Power Division of Omya Inc.; Notice of Application Accepted for Filing, Soliciting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-06

    ...); (6) an additional steel structure measuring 28 by 48 feet attached to the original powerhouse... maximum water surface elevation of 469.5 feet mean sea level (M.S.L); (3) a gated-forebay intake structure...: A 9-foot- diameter, 460-foot-long, riveted steel penstock that decreases to 8 feet diameter; and a 7...

  3. Relation of Stem Diameter, Branch Basal Area, and Leaf Biomass in Rapidly Growing Loblolly Pine

    Treesearch

    Thomas M. Williams; Charles A. Gresham

    2004-01-01

    Twenty loblolly pines, growing in International Paper’s maximum growth experiment at Bainbridge GA, were destructively sampled at the end of the sixth growing season. Ten trees in the control and 10 in the maximum treatment were sampled. All trees were planted at a 2.4- by 3.6-m spacing and grown with complete competition control. The maximum trees also received...

  4. Essential features of long-term changes of areas and diameters of sunspot groups in solar activity cycles 12-24

    NASA Astrophysics Data System (ADS)

    Efimenko, V. M.; Lozitsky, V. G.

    2018-06-01

    We analyze the Greenwich catalog data on areas of sunspot groups of last thirteen solar cycles. Various parameters of sunspots are considered, namely: average monthly smoothed areas, maximum area for each year and equivalent diameters of groups of sunspots. The first parameter shows an exceptional power of the 19th cycle of solar activity, which appears here more contrastively than in the numbers of spots (that is, in Wolf's numbers). It was found that in the maximum areas of sunspot groups for a year there is a unique phenomenon: a short and high jump in the 18th cycle (in 1946-1947) that has no analogues in other cycles. We also studied the integral distributions for equivalent diameters and found the following: (a) the average value of the index of power-law approximation is 5.4 for the last 13 cycles and (b) there is reliable evidence of Hale's double cycle (about 44 years). Since this indicator reflects the dispersion of sunspot group diameters, the results obtained show that the convective zone of the Sun generates embryos of active regions in different statistical regimes which change with a cycle of about 44 years.

  5. Cryogenic vertical test facility for the SRF cavities at BNL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Than, R.; Liaw, CJ; Porqueddu, R.

    2011-03-28

    A vertical test facility has been constructed to test SRF cavities and can be utilized for other applications. The liquid helium volume for the large vertical dewar is approximate 2.1m tall by 1m diameter with a clearance inner diameter of 0.95m after the inner cold magnetic shield installed. For radiation enclosure, the test dewar is located inside a concrete block structure. The structure is above ground, accessible from the top, and equipped with a retractable concrete roof. A second radiation concrete facility, with ground level access via a labyrinth, is also available for testing smaller cavities in 2 smaller dewars.more » The cryogenic transfer lines installation between the large vertical test dewar and the cryo plant's sub components is currently near completion. Controls and instrumentations wiring are also nearing completion. The Vertical Test Facility will allow onsite testing of SRF cavities with a maximum overall envelope of 0.9 m diameter and 2.1 m height in the large dewar and smaller SRF cavities and assemblies with a maximum overall envelope of 0.66 m diameter and 1.6 m height.« less

  6. TRANSVERSE IMPEDANCE OF THE SQUID GIANT AXON DURING CURRENT FLOW

    PubMed Central

    Cole, Kenneth S.; Baker, Richard F.

    1941-01-01

    The change in the transverse impedance of the squid giant axon caused by direct current flow has been measured at frequencies from 1 kc. per second to 500 kc. per second. The impedance change is equivalent to an increase of membrane conductance at the cathode to a maximum value approximately the same as that obtained during activity and a decrease at the anode to a minimum not far from zero. There is no evidence of appreciable membrane capacity change in either case. It then follows that the membrane has the electrical characteristics of a rectifier. Interpreting the membrane conductance as a measure of ion permeability, this permeability is increased at the cathode and decreased at the anode. PMID:19873233

  7. Implant-bone interface stress distribution in immediately loaded implants of different diameters: a three-dimensional finite element analysis.

    PubMed

    Ding, Xi; Zhu, Xing-Hao; Liao, Sheng-Hui; Zhang, Xiu-Hua; Chen, Hong

    2009-07-01

    To establish a 3D finite element model of a mandible with dental implants for immediate loading and to analyze stress distribution in bone around implants of different diameters. Three mandible models, embedded with thread implants (ITI, Straumann, Switzerland) with diameters of 3.3, 4.1, and 4.8 mm, respectively, were developed using CT scanning and self-developed Universal Surgical Integration System software. The von Mises stress and strain of the implant-bone interface were calculated with the ANSYS software when implants were loaded with 150 N vertical or buccolingual forces. When the implants were loaded with vertical force, the von Mises stress concentrated on the mesial and distal surfaces of cortical bone around the neck of implants, with peak values of 25.0, 17.6 and 11.6 MPa for 3.3, 4.1, and 4.8 mm diameters, respectively, while the maximum strains (5854, 4903, 4344 muepsilon) were located on the buccal cancellous bone around the implant bottom and threads of implants. The stress and strain were significantly lower (p < 0.05) with the increased diameter of implant. When the implants were loaded with buccolingual force, the peak von Mises stress values occurred on the buccal surface of cortical bone around the implant neck, with values of 131.1, 78.7, and 68.1 MPa for 3.3, 4.1, and 4.8 mm diameters, respectively, while the maximum strains occurred on the buccal surface of cancellous bone adjacent to the implant neck, with peak values of 14,218, 12,706, and 11,504 microm, respectively. The stress of the 4.1-mm diameter implants was significantly lower (p < 0.05) than those of 3.3-mm diameter implants, but not statistically different from that of the 4.8 mm implant. With an increase of implant diameter, stress and strain on the implant-bone interfaces significantly decreased, especially when the diameter increased from 3.3 to 4.1 mm. It appears that dental implants of 10 mm in length for immediate loading should be at least 4.1 mm in diameter, and uniaxial loading to dental implants should be avoided or minimized.

  8. Sub-Airy Confocal Adaptive Optics Scanning Ophthalmoscopy.

    PubMed

    Sredar, Nripun; Fagbemi, Oladipo E; Dubra, Alfredo

    2018-04-01

    To demonstrate the viability of improving transverse image resolution in reflectance scanning adaptive optics ophthalmoscopy using sub-Airy disk confocal detection. The foveal cone mosaic was imaged in five human subjects free of known eye disease using two custom adaptive optics scanning light ophthalmoscopes (AOSLOs) in reflectance with 7.75 and 4.30 mm pupil diameters. Confocal pinholes of 0.5, 0.6, 0.8, and 1.0 Airy disk diameters (ADDs) were used in a retinal conjugate plane before the light detector. Average cone photoreceptor intensity profile width and power spectrum were calculated for the resulting images. Detected energy using a model eye was recorded for each pinhole size. The cone photoreceptor mosaic is better resolved with decreasing confocal pinhole size, with the high spatial frequency content of the images enhanced in both the large- and small-pupil AOSLOs. The average cone intensity profile width was reduced by ∼15% with the use of a 0.5 ADD pinhole when compared to a 1.0 ADD, with an accompanying reduction in signal greater than a factor of four. The use of sub-Airy disk confocal pinhole detection without increasing retinal light exposure results in a substantial improvement in image resolution at the cost of larger than predicted signal reduction. Improvement in transverse resolution using sub-Airy disk confocal detection is a practical and low-cost approach that is applicable to all point- and line-scanning ophthalmoscopes, including optical coherence tomographers.

  9. MRI Simulation Study Investigating Effects of Vessel Topology, Diffusion, and Susceptibility on Transverse Relaxation Rates Using a Cylinder Fork Model.

    PubMed

    Shazeeb, Mohammed Salman; Kalpathy-Cramer, Jayashree; Issa, Bashar

    2017-11-24

    Brain vasculature is conventionally represented as straight cylinders when simulating blood oxygenation level dependent (BOLD) contrast effects in functional magnetic resonance imaging (fMRI). In reality, the vasculature is more complicated with branching and coiling especially in tumors. Diffusion and susceptibility changes can also introduce variations in the relaxation mechanisms within tumors. This study introduces a simple cylinder fork model (CFM) and investigates the effects of vessel topology, diffusion, and susceptibility on the transverse relaxation rates R2* and R2. Simulations using Monte Carlo methods were performed to quantify R2* and R2 by manipulating the CFM at different orientations, bifurcation angles, and rotation angles. Other parameters of the CFM were chosen based on physiologically relevant values: vessel diameters (~2‒10 µm), diffusion rates (1 × 10 -11 ‒1 × 10 -9  m 2 /s), and susceptibility values (3 × 10 -8 -4 × 10 -7 cgs units). R2* and R2 measurements showed a significant dependence on the bifurcation and rotation angles in several scenarios using different vessel diameters, orientations, diffusion rates, and susceptibility values. The angular dependence of R2* and R2 using the CFM could potentially be exploited as a tool to differentiate between normal and tumor vessels. The CFM can also serve as the elementary building block to simulate a capillary network reflecting realistic topological features.

  10. Do xylem fibers affect vessel cavitation resistance?

    PubMed

    Jacobsen, Anna L; Ewers, Frank W; Pratt, R Brandon; Paddock, William A; Davis, Stephen D

    2005-09-01

    Possible mechanical and hydraulic costs to increased cavitation resistance were examined among six co-occurring species of chaparral shrubs in southern California. We measured cavitation resistance (xylem pressure at 50% loss of hydraulic conductivity), seasonal low pressure potential (P(min)), xylem conductive efficiency (specific conductivity), mechanical strength of stems (modulus of elasticity and modulus of rupture), and xylem density. At the cellular level, we measured vessel and fiber wall thickness and lumen diameter, transverse fiber wall and total lumen area, and estimated vessel implosion resistance using (t/b)(h)(2), where t is the thickness of adjoining vessel walls and b is the vessel lumen diameter. Increased cavitation resistance was correlated with increased mechanical strength (r(2) = 0.74 and 0.76 for modulus of elasticity and modulus of rupture, respectively), xylem density (r(2) = 0.88), and P(min) (r(2) = 0.96). In contrast, cavitation resistance and P(min) were not correlated with decreased specific conductivity, suggesting no tradeoff between these traits. At the cellular level, increased cavitation resistance was correlated with increased (t/b)(h)(2) (r(2) = 0.95), increased transverse fiber wall area (r(2) = 0.89), and decreased fiber lumen area (r(2) = 0.76). To our knowledge, the correlation between cavitation resistance and fiber wall area has not been shown previously and suggests a mechanical role for fibers in cavitation resistance. Fiber efficacy in prevention of vessel implosion, defined as inward bending or collapse of vessels, is discussed.

  11. Sub-Airy Confocal Adaptive Optics Scanning Ophthalmoscopy

    PubMed Central

    Sredar, Nripun; Fagbemi, Oladipo E.

    2018-01-01

    Purpose To demonstrate the viability of improving transverse image resolution in reflectance scanning adaptive optics ophthalmoscopy using sub-Airy disk confocal detection. Methods The foveal cone mosaic was imaged in five human subjects free of known eye disease using two custom adaptive optics scanning light ophthalmoscopes (AOSLOs) in reflectance with 7.75 and 4.30 mm pupil diameters. Confocal pinholes of 0.5, 0.6, 0.8, and 1.0 Airy disk diameters (ADDs) were used in a retinal conjugate plane before the light detector. Average cone photoreceptor intensity profile width and power spectrum were calculated for the resulting images. Detected energy using a model eye was recorded for each pinhole size. Results The cone photoreceptor mosaic is better resolved with decreasing confocal pinhole size, with the high spatial frequency content of the images enhanced in both the large- and small-pupil AOSLOs. The average cone intensity profile width was reduced by ∼15% with the use of a 0.5 ADD pinhole when compared to a 1.0 ADD, with an accompanying reduction in signal greater than a factor of four. Conclusions The use of sub-Airy disk confocal pinhole detection without increasing retinal light exposure results in a substantial improvement in image resolution at the cost of larger than predicted signal reduction. Translational Relevance Improvement in transverse resolution using sub-Airy disk confocal detection is a practical and low-cost approach that is applicable to all point- and line-scanning ophthalmoscopes, including optical coherence tomographers. PMID:29629239

  12. A newly developed oval-shaped port device (E•Z ACCESS Oval type) for use in reduced port surgery: initial clinical experiences with cholecystectomy.

    PubMed

    Shibao, Kazunori; Takagi, Tsuyoshi; Higure, Aiichiro; Yamaguchi, Koji

    2013-09-01

    We recently developed an oval-shaped E•Z Access device designed exclusively for use with the LAP PROTECTOR™ Oval type device (Hakko Co. Ltd., Tokyo, Japan). The transverse abdominal opening diameter made by round-shaped (Alexis® Wound Retractor, Applied Medical, Rancho Santa Margarita, CA; and LAP PROTECTOR™ Round type) and oval-shaped (LAP PROTECTOR™ Oval type) wound retractors was measured and compared in 5 patients with cholecystolithiasis. Each device was placed through a single 25-mm longitudinal umbilical incision, and the length of trocar separation was compared. LESS cholecystectomy was then performed using the oval-shaped E•Z ACCESS/LAP PROTECTOR™. The transverse abdominal opening diameter was maximized with the LAP PROTECTOR™ Oval type device. The average distance between the working-ports for the glove method, round-shaped, and oval-shaped E•Z ACCESS/LAP PROTECTOR™ devices in the 25-mm umbilical incisions were 20 ± 0.8 mm, 24 ± 1.5 mm, and 35 ± 0.8 mm, respectively. Wider trocar separation was achieved using the oval-shaped device, making the surgical procedures easier to perform. No perioperative port-related or surgical complications were observed. LESS cholecystectomy using the E•Z ACCESS Oval type device was found to be technically feasible. The Oval type device appears to allow for wider trocar separation, thereby reducing stress on the surgeon, ensuring patient safety, and providing cosmetic benefits.

  13. High-Subsonic Performance Characteristics and Boundary-Layer Investigations of a 12 deg 10-Inch-Inlet-Diameter Conical Diffuser

    DTIC Science & Technology

    1950-05-11

    available condition supersonic flow was obtained as far as K.5 inches downstream from the diffueer inlet with a maximum Mach number of M % 1.5...Boundary—layer total-pressure measurements were made with the rake shown in figure k. The tubes varied in size from 0.030-Inch outside diameter...at the wall to 0.050—inch outside diameter farther out. A static-pressure tube was mounted on the rake to measure static pressures at the same

  14. A Retrospective Evaluation of Echocardiograms to Establish Normative Inferior Vena Cava and Aortic Measurements for Children Younger Than 6 Years.

    PubMed

    Stenson, Erin K; Punn, Rajesh; Ramsi, Musaab; Kache, Saraswati

    2018-02-26

    The ability to plot the inferior vena cava (IVC) size on a normal curve for pediatric patients may prove beneficial. First, in patients with normal cardiac anatomy who present in shock, assessing IVC size may be valuable for evaluating the degree of dehydration. Second, in children with heart disease, understanding how a child's IVC size compares to normal could be particularly beneficial for patients with right heart disease. We sought to create normal curves for the IVC and aorta in children younger than 6 years. Data were gathered from 347 echocardiograms of healthy children younger than 6 years in a retrospective study at a quaternary care children's hospital. From the subcostal long- and short-axis images, maximum diameters in the transverse and longitudinal views were obtained for both the IVC and the aorta. Both IVC and aortic dimensions increased in a linear fashion and had excellent correlations with the body surface area, body mass, and height (IVC, r = 0.78-0.81; P < .0001; aorta, r = 0.82-0.86; P < .0001). In children younger than 6 years, the IVC and aorta increase linearly as the children grow. Such normal curves will be beneficial for assessing a pediatric patient's hydration status or right heart function in patients with congenital heart disease. © 2018 by the American Institute of Ultrasound in Medicine.

  15. Tailoring the transverse mode of a high-finesse optical resonator with stepped mirrors

    NASA Astrophysics Data System (ADS)

    Högner, M.; Saule, T.; Lilienfein, N.; Pervak, V.; Pupeza, I.

    2018-02-01

    Enhancement cavities (ECs) seeded with femtosecond pulses have developed into the most powerful technique for high-order harmonic generation (HHG) at repetition rates in the tens of MHz. Here, we demonstrate the feasibility of controlling the phase front of the excited transverse eigenmode of a ring EC by using mirrors with stepped surface profiles, while maintaining the high finesse required to reach the peak intensities necessary for HHG. The two lobes of a {{TEM}}01 mode of a 3.93 m long EC, seeded with a single-frequency laser, are delayed by 15.6 fs with respect to each other before a tight focus, and the delay is reversed after the focus. The tailored transverse mode exhibits an on-axis intensity maximum in the focus. Furthermore, the geometry is designed to generate a rotating wavefront in the focus when few-cycle pulses circulate in the EC. This paves the way to gating isolated attosecond pulses (IAPs) in a transverse manner (similarly to the attosecond lighthouse), heralding IAPs at repetition rates well into the multi-10 MHz range. In addition, these results promise high-efficiency harmonic output coupling from ECs in general, with an unparalleled power scalability. These prospects are expected to tremendously benefit photoelectron spectroscopy and extreme-ultraviolet frequency comb spectroscopy.

  16. [Body build and radiation exposure in static roentgen studies (I): A contribution for determining a national reference dose value. Promoted by the Federal Office for Radiation Protection (St.Sch 4163)].

    PubMed

    Golder, W; Weiner, G

    2001-06-01

    To contribute data on radiation exposure in static x-ray procedures and to compare them with anthropometric parameters. 121 chest x-rays and 100 lumbar spine examinations were carried out and the dose-area product (DAP) measured for each of the projections. Additionally, body height, body weight and the sagittal and transversal diameters of the examined regions were recorded. Dose measurements were statistically evaluated and the following data determined: Frequency distribution, median, 25%- and 75%-percentiles as well as correlations with sex, body weight and diameters. Median DAP was 13 (men: 16; women: 11) resp. 50 (62; 37) cGycm2 with pa resp lateral chest x-ray. Values were closely correlated with body weight (r = 0.704/0.659) and diameter of the chest (r = 0.657/0.579). Median DAP was 175 (239; 126) resp 531 (670; 361) cGycm2 with ap resp lateral lumbar spine examinations. Values were closely correlated with body weight (r = 0.678/0.666) and diameter of the abdomen (r = 0.664/0.658). DAP of chest x-rays and lumbar spine examinations is strongly influenced by the constitution of the patients. Men are nearly twice as largely exposed to radiation as women.

  17. Transverse Coherence Limited Coherent Diffraction Imaging using a Molybdenum Soft X-ray Laser Pumped at Moderate Pump Energies.

    PubMed

    Zürch, M; Jung, R; Späth, C; Tümmler, J; Guggenmos, A; Attwood, D; Kleineberg, U; Stiel, H; Spielmann, C

    2017-07-13

    Coherent diffraction imaging (CDI) in the extreme ultraviolet has become an important tool for nanoscale investigations. Laser-driven high harmonic generation (HHG) sources allow for lab scale applications such as cancer cell classification and phase-resolved surface studies. HHG sources exhibit excellent coherence but limited photon flux due poor conversion efficiency. In contrast, table-top soft X-ray lasers (SXRL) feature excellent temporal coherence and extraordinary high flux at limited transverse coherence. Here, the performance of a SXRL pumped at moderate pump energies is evaluated for CDI and compared to a HHG source. For CDI, a lower bound for the required mutual coherence factor of |μ 12 | ≥ 0.75 is found by comparing a reconstruction with fixed support to a conventional characterization using double slits. A comparison of the captured diffraction signals suggests that SXRLs have the potential for imaging micron scale objects with sub-20 nm resolution in orders of magnitude shorter integration time compared to a conventional HHG source. Here, the low transverse coherence diameter limits the resolution to approximately 180 nm. The extraordinary high photon flux per laser shot, scalability towards higher repetition rate and capability of seeding with a high harmonic source opens a route for higher performance nanoscale imaging systems based on SXRLs.

  18. Optimizing parameter of particle damping based on Leidenfrost effect of particle flows

    NASA Astrophysics Data System (ADS)

    Lei, Xiaofei; Wu, Chengjun; Chen, Peng

    2018-05-01

    Particle damping (PD) has strongly nonlinearity. With sufficiently vigorous vibration conditions, it always plays excellent damping performance and the particles which are filled into cavity are on Leidenfrost state considered in particle flow theory. For investigating the interesting phenomenon, the damping effect of PD on this state is discussed by the developed numerical model which is established based on principle of gas and solid. Furtherly, the numerical model is reformed and applied to study the relationship of Leidenfrost velocity with characteristic parameters of PD such as particle density, diameter, mass packing ratio and diameter-length ratio. The results indicate that particle density and mass packing ratio can drastically improve the damping performance as opposed as particle diameter and diameter-length ratio, mass packing ratio and diameter-length ratio can low the excited intensity for Leidenfrost state. For discussing the application of the phenomenon in engineering, bound optimization by quadratic approximation (BOBYQA) method is employed to optimize mass packing ratio of PD for minimize maximum amplitude (MMA) and minimize total vibration level (MTVL). It is noted that the particle damping can drastically reduce the vibrating amplitude for MMA as Leidenfrost velocity equal to the vibrating velocity relative to maximum vibration amplitude. For MTVL, larger mass packing ratio is best option because particles at relatively wide frequency range is adjacent to Leidenfrost state.

  19. Heat transfer to small horizontal cylinders immersed in a fluidized bed

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Friedman, J.; Koundakjian, P.; Naylor, D.

    2006-10-15

    Heat transfer to horizontal cylinders immersed in fluidized beds has been extensively studied, but mainly in the context of heat transfer to boiler tubes in coal-fired beds. As a result, most correlations in the literature have been derived for cylinders of 25-50 mm diameter in vigorously fluidizing beds. In recent years, fluidized bed heat treating furnaces fired by natural gas have become increasingly popular, particularly in the steel wire manufacturing industry. These fluidized beds typically operate at relatively low fluidizing rates and with small diameter wires (1-6 mm). Nusselt number correlations developed based on boiler tube studies do not extrapolatemore » down to these small size ranges and low fluidizing rates. In order to obtain reliable Nusselt number data for these size ranges, an experimental investigation has been undertaken using two heat treating fluidized beds; one a pilot-scale industrial unit and the other a lab-scale (300 mm diameter) unit. Heat transfer measurements were obtained using resistively heated cylindrical samples ranging from 1.3 to 9.5 mm in diameter at fluidizing rates ranging from approximately 0.5 x G{sub mf} (packed bed condition) to over 10 x G{sub mf} using aluminum oxide sand particles ranging from d{sub p}=145-330 {mu}m (50-90 grit). It has been found that for all cylinder sizes tested, the Nusselt number reaches a maximum near 2 x G{sub mf}, then remains relatively steady ({+-}5-10%) to the maximum fluidizing rate tested, typically 8-12xG{sub mf}. A correlation for maximum Nusselt number is developed.« less

  20. Incidence, treatment and outcome of rectal stenosis following transanal endoscopic microsurgery.

    PubMed

    Barker, J A; Hill, J

    2011-09-01

    As an alternative to more radical abdominal surgery, transanal endoscopic microsurgery (TEM) offers a minimally invasive solution for the excision of certain rectal polyps and early-stage rectal tumours. The patient benefits of TEM as compared to radical abdominal surgery are clear; nevertheless, some drawback is possible. The aim of our study was to determine the risk factors, treatment and outcomes of rectal stenosis following TEM. We analysed a series of 354 consecutive patients who underwent TEM for benign or malignant rectal tumours between 1997 and 2009. We recorded the maximum histological diameter of the lesion, and whether the lesion was circumferential. Rectal stenosis was defined as a rectal narrowing not allowing passage of a 12 mm sigmoidoscope. Histological results with a measured specimen diameter were available in 304 of the 354 cases. There were 11 stenoses in total (3.6%), 7 stenoses due to 9 circumferential lesions (78%) and 4 due to lesions with a maximum diameter ≥ 5 cm (3.2%). Two patients presented as emergencies, and the other 9 patients reported symptoms of increased stool frequency at follow-up. Three of the stenoses were associated with recurrent disease. All stenoses were treated by a combination of endoscopic/radiological balloon dilatation or surgically with Hegar's dilators. A median of two procedures were required to treat stenoses until resolution of symptoms. Rectal stenosis following TEM excision is rare. It is predictable in patients with circumferential lesions but is rare in patients with non-circumferential lesions with a maximum diameter ≥ 5 cm. It is effectively treated with surgical or balloon dilatation. Most patients require repeated treatments.

  1. Effects of parasagittal meningiomas on intracranial venous circulation assessed by the virtual reality technology.

    PubMed

    Wang, Shousen; Ying, Jianbin; Wei, Liangfeng; Li, Shiqing; Jing, Junjie

    2015-01-01

    This study is to investigate the compensatory intracranial venous pathways in parasagittal meningiomas (PSM) patients by virtual reality technology. A total of 48 PSM patients (tumor group) and 20 patients with trigeminal neuralgia and hemifacial spasm but without intracranial venous diseases (control group) were enrolled. All patients underwent 3D CE-MRV examination. The 3D reconstructed images by virtual reality technology were used for assessment of diameter and number of intracranial veins, tumor location, venous sinus invasion degree and collateral circulation formation. Diameter of bridging veins in posterior 1/3 superior sagittal sinus (SSS) in tumor group was significantly smaller than that of the control group (P < 0.05). For tumors located in mid 1/3 SSS, diameter of bridging veins and vein of Labbé (VL) in posterior 1/3 SSS decreased significantly (P < 0.05). For tumors located in posterior 1/3 SSS, bridging vein number and transverse sinus (TS) diameter significantly decreased while superficial Sylvian vein (SSV) diameter increased significantly (P < 0.05). Compared with tumor in posterior 1/3 SSS subgroup, number of bridging veins in the tumor in mid 1/3 SSS subgroup increased significantly (P < 0.05). Compared with control group, only the bridging vein number in anterior 1/3 SSS segment in invasion Type 3-4 tumor subgroup decreased significantly (P < 0.05). Diameter of TS and bridging veins in posterior 1/3 SSS segment in sinus invasion Type 5-6 tumor subgroup decreased significantly (P < 0.05). Compared with control group, only the diameter of VL and TS of collateral circulation Grade 1 tumor subgroup decreased significantly (P < 0.05) while in Grade 3 tumor subgroup, TS diameter decreased and SSV diameter increased significantly (P < 0.05). The intracranial blood flow is mainly drained through SSV drainage after SSS occlusion by PSM.

  2. Effects of parasagittal meningiomas on intracranial venous circulation assessed by the virtual reality technology

    PubMed Central

    Wang, Shousen; Ying, Jianbin; Wei, Liangfeng; Li, Shiqing; Jing, Junjie

    2015-01-01

    Objective: This study is to investigate the compensatory intracranial venous pathways in parasagittal meningiomas (PSM) patients by virtual reality technology. Methods: A total of 48 PSM patients (tumor group) and 20 patients with trigeminal neuralgia and hemifacial spasm but without intracranial venous diseases (control group) were enrolled. All patients underwent 3D CE-MRV examination. The 3D reconstructed images by virtual reality technology were used for assessment of diameter and number of intracranial veins, tumor location, venous sinus invasion degree and collateral circulation formation. Results: Diameter of bridging veins in posterior 1/3 superior sagittal sinus (SSS) in tumor group was significantly smaller than that of the control group (P < 0.05). For tumors located in mid 1/3 SSS, diameter of bridging veins and vein of Labbé (VL) in posterior 1/3 SSS decreased significantly (P < 0.05). For tumors located in posterior 1/3 SSS, bridging vein number and transverse sinus (TS) diameter significantly decreased while superficial Sylvian vein (SSV) diameter increased significantly (P < 0.05). Compared with tumor in posterior 1/3 SSS subgroup, number of bridging veins in the tumor in mid 1/3 SSS subgroup increased significantly (P < 0.05). Compared with control group, only the bridging vein number in anterior 1/3 SSS segment in invasion Type 3-4 tumor subgroup decreased significantly (P < 0.05). Diameter of TS and bridging veins in posterior 1/3 SSS segment in sinus invasion Type 5-6 tumor subgroup decreased significantly (P < 0.05). Compared with control group, only the diameter of VL and TS of collateral circulation Grade 1 tumor subgroup decreased significantly (P < 0.05) while in Grade 3 tumor subgroup, TS diameter decreased and SSV diameter increased significantly (P < 0.05). Conclusions: The intracranial blood flow is mainly drained through SSV drainage after SSS occlusion by PSM. PMID:26550184

  3. A morphometric study of the atlas occipitalization and coexisted congenital anomalies of the vertebrae and posterior cranial fossa with neurological importance.

    PubMed

    Natsis, Konstantinos; Lyrtzis, Christos; Totlis, Trifon; Anastasopoulos, Nikolaos; Piagkou, Maria

    2017-01-01

    Our study highlights the morphometry of the partial and complete atlas occipitalization (AOZ), its coexistence with fusions of the 2nd and 3rd cervical vertebrae and morphological and morphometric abnormalities of the posterior cranial fossa that are of paramount neurological importance. One hundred and eighty adult dry skulls, the atlas and axis vertebrae were examined. Four skulls (2.2 %) showed AOZ. Two of them (1.1 %) presented a partial AOZ, one male skull (0.6 %) a complete AOZ and a female skull (0.6 %) had a fused left hemiatlas with the occipital bone and a fusion of the 2nd and 3rd cervical vertebrae. The inner anteroposterior and transverse diameters of the foramen magnum (FM) in the control group were 34.6 ± 3.46 and 29.3 ± 3.47 mm. Only the skull with the complete AOZ had a reduced outer anteroposterior diameter of the FM (29.8 mm), while no specimen was found with a reduced transverse diameter. A wide total decrease (range 13.1-50.9 %) in the surface area of the FM in skulls with AOZ was detected. Extracranial, the clivus length in two skulls with AOZ was smaller than the normal range. No skull was detected with a reduction in the intracranial length of the clivus. All skulls with the AOZ had a vermian fossa. The study adds important morphometric details about the partial and complete AOZ and correlates the phenomenon of synostosis with the narrowing of the FM, particularly in the case of complete AOZ. Awareness of the AOZ and other fusions of the upper cervical vertebrae and their topographical relations and attendant problems are of paramount importance to surgeons, when operate to the craniocervical junction, or interpret imaging studies to plan a safe surgery for nerve or spinal tissue decompression.

  4. Focal Hydrothermal Ablation: Preliminary Investigation of a New Concept

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roy, Sumit, E-mail: sumit.roy@online.no

    2013-08-01

    PurposeTo determine whether focal tissue ablation is possible with interstitial instillation of steam.MethodsFresh swine livers were used. Through a 20 gauge needle, steam was instilled every 5 s, 3 (n = 5), 6 (n = 5), 9 (n = 5), or 12 (n = 5 + 5) times in a liver lobe. The ablated zones were sectioned parallel (n = 20) or perpendicular (n = 5) to the needle track. The longitudinal long and short axis diameters, or transverse long and short axis diameters of areas with discoloration on macroscopic examination, were measured. The experiment was repeated in vivo onmore » a pig. Steam instillation was performed once every 5 s for 5 min in the liver (n = 3) and in muscle (n = 4), and temperature changes at three neighboring sites were monitored. Long and short axis diameters of the discolored areas were measured.ResultsA well-defined area of discoloration was invariably present at the site of steam instillation. The median longitudinal long axis diameter were 2.0, 2.5, 2.5, and 3.5 cm for 3, 6, 9, and 12 steam instillations in vitro, while median short axis diameters were 1.0, 1.5, 1.5, and 1.5 cm, respectively. Six attempts at ablation in vivo could be successfully completed. The long axis diameters of the ablated zones in the liver were 7.0 and 8.0 cm, while in muscle it ranged from 5.5 to 7.0 cm.ConclusionInstillation of steam in the liver in vitro and in vivo, and in muscle in vivo rapidly leads to circumscribed zones of coagulation necrosis.« less

  5. The impact of clinical use on the torsional behavior of Reciproc and WaveOne instruments

    PubMed Central

    de MAGALHÃES, Rafael Rodrigues Soares; BRAGA, Lígia Carolina Moreira; PEREIRA, Érika Sales Joviano; PEIXOTO, Isabella Faria da Cunha; BUONO, Vicente Tadeu Lopes; BAHIA, Maria Guiomar de Azevedo

    2016-01-01

    ABSTRACT Torsional overload is a fracture representative parameter for instruments in single-file techniques. Objective The aim of this study was to assess the influence of clinical use, in vivo, on the torsional behavior of Reciproc and WaveOne instruments considering the possibility that they degraded with use. Material and Methods Diameter at each millimeter, pitch length, and area at 3 mm from the tip were determined for both types of instruments. Twenty-four instruments, size 25, 0.08 taper, of each system were divided into two groups (n=12 each): Control Group (CG), in which new Reciproc (RC) and WaveOne Primary (WO) instruments were tested in torsion until rupture based on ISO 3630-1; and Experimental Group (EG), in which each new instrument was clinically used to clean and shape the root canals of one molar. After clinical use, the instruments were analyzed using optical and scanning electron microscopy and subsequently tested in torsion until fracture. Data were analyzed using one-way analysis of variance at a=.05. Results WO instruments showed significantly higher mean values of cross-sectional area A3 (P=0.000) and smaller pitch lengths than RC instruments with no statistically significant differences in the diameter at D3 (P=0.521). No significant differences in torsional resistance between the RC and WO new instruments (P=0.134) were found. The clinical use resulted in a tendency of reduction in the maximum torque of the analyzed instruments but no statistically significant difference was observed between them (P=0.327). During the preparation of the root canals, two fractured RC instruments and longitudinal and transversal cracks in RC and WO instruments were observed through SEM analysis. Conclusion After clinical use, no statistically significant reduction in the torsional resistance was observed. PMID:27556200

  6. Annular ring zoom system using two positive axicons

    NASA Astrophysics Data System (ADS)

    Dickey, Fred M.; Conner, Jacob D.

    2011-10-01

    The production of an annular ring of light with a variable diameter has applications in laser material processing and machining, particle manipulation, and corneal surgery. This can readily be accomplished using a positive and negative axicon pair. However, negative axicons are very expensive and difficult to obtain with small diameters. In this paper, we present a design of an annular ring zoom system using two positive axicons. One axicon is placed a distance before a primary lens that is greater than some prescribed minimum, and the second axicon is placed after the primary lens. The position of the second axicon determines the ring diameter. The ring diameter can be zoomed from some maximum design size to a zero diameter ring (spot). Experimental results from a developmental system will be presented.

  7. Diameter-Constrained Steiner Tree

    NASA Astrophysics Data System (ADS)

    Ding, Wei; Lin, Guohui; Xue, Guoliang

    Given an edge-weighted undirected graph G = (V,E,c,w), where each edge e ∈ E has a cost c(e) and a weight w(e), a set S ⊆ V of terminals and a positive constant D 0, we seek a minimum cost Steiner tree where all terminals appear as leaves and its diameter is bounded by D 0. Note that the diameter of a tree represents the maximum weight of path connecting two different leaves in the tree. Such problem is called the minimum cost diameter-constrained Steiner tree problem. This problem is NP-hard even when the topology of Steiner tree is fixed. In present paper we focus on this restricted version and present a fully polynomial time approximation scheme (FPTAS) for computing a minimum cost diameter-constrained Steiner tree under a fixed topology.

  8. Hydrostatic Bearing Pad Maximum Load and Overturning Conditions for the 70-meter Antenna

    NASA Technical Reports Server (NTRS)

    Mcginness, H. D.

    1985-01-01

    The reflector diameters of the 64-m antennas were increased to 70-m. In order to evaluate the minimum film thickness of the hydrostatic bearing which supports the antenna weight, it is first necessary to have a good estimation of the maximum operational load on the most heavily loaded bearing pad. The maximum hydrostatic bearing load is shown to be sufficiently small and the ratios of stabilizing to over turning moments are ample.

  9. Whole-tree harvesting of pines with taproot attached

    Treesearch

    P. Koch

    1974-01-01

    The taproot of a 15- to 3O-yearold slash pine, with lateral roots pruned away, weighs about 20% as much as the bark-free merchantable stem to a four-inch top (dry-weight basis). Maximum taproot diameter, a few inches below ground level, is 1.5 to two times stem diameter at breast height. Length in sandy loam soils is commonly three to five feet.

  10. Five Years' Growth of Pruned and Unpruned Cottonwood Planted at 40- by 40-Foot Spacing

    Treesearch

    Roger M. Krinard

    1979-01-01

    Four pruning treatments have been applied for 5 years on cottonwood (Populus deltoides Bartr.) select clone Stoneville 66, planted at 40- by 40-ft spacing. As pruning severity increased, average diameter and maximum crown width decreased. Diameters ranged from 9.2 inches for trees pruned half of height yearly to 11.4 inches for unpruned trees; crown widths ranged from...

  11. Modeling Caribbean tree stem diameters from tree height and crown width measurements

    Treesearch

    Thomas Brandeis; KaDonna Randolph; Mike Strub

    2009-01-01

    Regression models to predict diameter at breast height (DBH) as a function of tree height and maximum crown radius were developed for Caribbean forests based on data collected by the U.S. Forest Service in the Commonwealth of Puerto Rico and Territory of the U.S. Virgin Islands. The model predicting DBH from tree height fit reasonably well (R2 = 0.7110), with...

  12. Morphological Differences in the Aorto-iliac Segment in AAA Patients of Caucasian and Asian Origin.

    PubMed

    Banzic, I; Lu, Q; Zhang, L; Stepak, H; Davidovic, L; Oszkinis, G; Mladenovic, A; Markovic, M; Rancic, Z; Jing, Z; Brankovic, M

    2016-06-01

    The objective was to quantify aorto-iliac morphology differences between AAA patients of Caucasian and Asian origin. Additionally, the impact of patient demographic characteristics was assessed, which could influence the morphological differences. This international multicentre study included two tertiary referral institutions from Europe and one from China. CT scans with 3D reconstruction of 296 patients with infrarenal AAA >5 cm were analysed. Eighteen measurements were recorded from each CT scan and compared between Caucasian and Asian patients. Caucasian patients had longer common iliac arteries (right: 65.0 vs. 33.1 mm, p < .001 left: 65.0 vs. 35.2 mm, p < .001), longer aneurysm neck (33.0 vs. 28.4 mm, p < .001), greater aneurysm to aortic axis angle (153.0° vs. 142.2°, p < .001), and longer combined aorto-iliac length (195.7 vs. 189.2 mm, p < .001). However, Asian patients had a longer infrarenal abdominal aorta (152.0 vs. 130.0 mm, p < .001), longer AAA (126.2 vs. 93.0 mm), and greater linear distance from renal artery to aorto-iliac bifurcation (143.6 vs. 116.0 mm, p < .001). Caucasian patients had a larger inner common iliac artery diameter (right: 16.0 vs. 14.9 mm, p < .001, left: 16.0 vs. 15.2 mm, p < .001), larger inner exernal iliac artery diameter (right: 9.0 vs. 7.5 mm, p < .001 left: 9.0 vs. 7.7 mm, p < .001), and larger inner common femoral artery diameter (right: 10.0 vs. 5.9 mm, p < .001 left: 10.0 vs. 6.1 mm, p < .001). No difference was observed in AAA transverse diameter (62.0 vs. 63.1 mm, p = .492). The results showed that aorto-iliac anatomy in Caucasians differs significantly from Asians, particularly in the length of the common iliac arteries and infrarenal abdominal aorta, and in the transverse diameter of the common, external iliac, and common femoral arteries. Therefore, the exact criteria for stent graft design are dependent on the racial origin of the patient. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  13. A comparison of hydraulic architecture in three similarly sized woody species differing in their maximum potential height

    Treesearch

    Katherine A. McCulloh; Daniel M. Johnson; Joshua Petitmermet; Brandon McNellis; Frederick C. Meinzer; Barbara Lachenbruch; Nathan Phillips

    2015-01-01

    The physiological mechanisms underlying the short maximum height of shrubs are not understood. One possible explanation is that differences in the hydraulic architecture of shrubs compared with co-occurring taller trees prevent the shrubs from growing taller. To explore this hypothesis, we examined various hydraulic parameters, including vessel lumen diameter,...

  14. A surface fuel classification for estimating fire effects

    Treesearch

    Duncan C. Lutes; Robert E. Keane; John F. Caratti

    2009-01-01

    We present a classification of duff, litter, fine woody debris, and logs that can be used to stratify a project area into sites with fuel loading that yield significantly different emissions and maximum soil surface temperature. Total particulate matter smaller than 2.5?m in diameter and maximum soil surface temperature were simulated using the First...

  15. Wrinkling of reinforced plates subjected to shear stresses

    NASA Technical Reports Server (NTRS)

    Seydel, Edgar

    1931-01-01

    An analysis is made here of the problem of long plates with transverse stiffeners subject to shear. A typical example would be a long Wagner beam. The shear stress is calculated at which the web wrinkles and shear stress becomes a maximum. The equation is solved for both a condition of free support and rigidity of support on the edges.

  16. Change of heart dimensions and function during pregnancy in goats.

    PubMed

    Szaluś-Jordanow, Olga; Czopowicz, Michał; Witkowski, Lucjan; Moroz, Agata; Mickiewicz, Marcin; Frymus, Tadeusz; Markowska-Daniel, Iwona; Bagnicka, Emilia; Kaba, Jarosław

    2018-03-08

    The study aimed to evaluate the effect of pregnancy on heart diameters and function in goats. Transthoracic echocardiography of 12 female dairy goats of two Polish regional breeds was performed. A Mindray M7 diagnostic ultrasound system with Phased Array transducer was used. Simultaneously, electrocardiography was recorded. All animals were examined four times - at mating season, at the end of the first trimester, at the end of the second trimester and just before kidding. Eleven measurements were taken each time: aortic and left atrial diameter (AoD and LAD), right and left ventricular internal diameter in diastole (RVIDd and LVIDd), left ventricular internal diameter in systole (LVIDs), inter-ventricular septum thickness in diastole and systole (IVSd and IVSd) and left ventricular posterior wall in diastole and systole (LVPWd and LVPWs), maximum left and right ventricular outflow tract velocity (RVOT Vmax and LVOT Vmax). Nine consecutive measurements were derived: the ratio of the left atrial diameter to the aortic diameter (AoD/LAD), left ventricular fractional shortening (FS%), left ventricular ejection fraction (EF%), maximum outflow tract pressure gradients (RVOT PGmax and LVOT PGmax), left ventricular end-diastolic volume (LVEDV) and left ventricular end-systolic volume (LVESV), stroke volume (SV) and cardiac output (CO). HR, LAD, LVPWs, IVSs increased significantly in the first trimester. AoD and RVIDd were significantly higher around parturition. LVIDd, FS%, EF%, SV and CO rose both in the first and third trimester. No measurement decreased during pregnancy. The study confirms that pregnancy causes changes in the heart size and functioning. Copyright © 2018. Published by Elsevier Ltd.

  17. High efficiency single transverse mode photonic band crystal lasers with low vertical divergence

    NASA Astrophysics Data System (ADS)

    Zhao, Shaoyu; Qu, Hongwei; Liu, Yun; Li, Lunhua; Chen, Yang; Zhou, Xuyan; Lin, Yuzhe; Liu, Anjin; Qi, Aiyi; Zheng, Wanhua

    2016-10-01

    High efficiency 980 nm longitudinal photonic band crystal (PBC) edge emitting laser diodes are designed and fabricated. The calculated results show that eight periods of Al0.1Ga0.9As and Al0.25Ga0.75As layer pairs can reduce the vertical far field divergence to 10.6° full width at half maximum (FWHM). The broad area (BA) lasers show a very high internal quantum efficiency ηi of 98% and low internal loss αi of 1.92 cm-1. Ridge waveguide (RW) lasers with 3 mm cavity length and 5um strip width provide 430 mW stable single transverse mode output at 500 mA injection current with power conversion efficiency (PCE) of 47% under continuous wave (CW) mode. A maximum PCE of 50% is obtained at the 300 mA injection current. A very low vertical far field divergence of 9.4° is obtained at 100 mA injection. At 500 mA injection, the vertical far field divergence increases to 11°, the beam quality factors M2 values are 1.707 in vertical direction and 1.769 in lateral direction.

  18. Diffraction of SH-waves by topographic features in a layered transversely isotropic half-space

    NASA Astrophysics Data System (ADS)

    Ba, Zhenning; Liang, Jianwen; Zhang, Yanju

    2017-01-01

    The scattering of plane SH-waves by topographic features in a layered transversely isotropic (TI) half-space is investigated by using an indirect boundary element method (IBEM). Firstly, the anti-plane dynamic stiffness matrix of the layered TI half-space is established and the free fields are solved by using the direct stiffness method. Then, Green's functions are derived for uniformly distributed loads acting on an inclined line in a layered TI half-space and the scattered fields are constructed with the deduced Green's functions. Finally, the free fields are added to the scattered ones to obtain the global dynamic responses. The method is verified by comparing results with the published isotropic ones. Both the steady-state and transient dynamic responses are evaluated and discussed. Numerical results in the frequency domain show that surface motions for the TI media can be significantly different from those for the isotropic case, which are strongly dependent on the anisotropy property, incident angle and incident frequency. Results in the time domain show that the material anisotropy has important effects on the maximum duration and maximum amplitudes of the time histories.

  19. A wire scanner system for characterizing the BNL energy recovery LINAC beam position monitor system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michnoff R.; Biscardi, C.; Cerniglia, P.

    2012-04-15

    A stepper motor controlled wire scanner system has recently been modified to support testing of the Brookhaven National Laboratory (BNL) Collider-Accelerator department's Energy Recovery Linac (ERL) beam position monitor (BPM) system. The ERL BPM consists of four 9.33 mm diameter buttons mounted at 90 degree spacing in a cube with 1.875 inch inside diameter. The buttons were designed by BNL and fabricated by Times Microwave Systems. Libera brilliance single pass BPM electronic modules with 700 MHz bandpass filter, manufactured by Instrumentation Technologies, will be used to measure the transverse beam positions at 14 locations around the ERL. The wire scannermore » assembly provides the ability to measure the BPM button response to a pulsed wire, and evaluate and calibrate the Libera position measurement electronics. A description of the wire scanner system and test result data will be presented.« less

  20. Direct laser writing of a low-loss waveguide with independent control over the transverse dimension and the refractive index contrast between the core and the cladding.

    PubMed

    Masselin, Pascal; Bychkov, Eugène; Coq, David Le

    2016-08-01

    In this Letter, we present the realization of a low-loss waveguide in a chalcogenide glass by direct laser writing technique in a particular configuration that allows the independent control over the diameter of the core and the magnitude of the refractive index contrast with the cladding. The waveguide is of multicore type and composed of 19 channels arranged on a hexagonal lattice. Each channel is obtained by stacking voxels of refractive index variation obtained by static exposure to femtosecond laser pulse burst. The distance between the channels can be used to vary the diameter of the waveguide, while the duration of laser burst controls the magnitude of the effective index and the propagation loss. We demonstrate that it can be reduced down to 0.11 dB/cm.

  1. Description of a new species of the genus Mongolotettix Rehn, 1928 (Orthoptera: Acrididae) from Fujian, China.

    PubMed

    Chen, Shen-Zhi; Shi, Jian-Ping; Dai, Li

    2018-04-17

    A new species of the genus Mongolotettix Rehn, 1928 from Fujian, China is described in this paper. The new species Mongolotettix.fujianensis sp. nov. is similar to M. wulingyuanensis Shi, Liu et Li, 2016, but differs from the latter by maximum width of cubital area 1.4 times maximum width of medial area in tegmina of male; body small, length of body ♂ 21.5. mm, ♀ 30.6 mm; vertical diameter eye 1.3 times horizontal diameter in male; hind femur of male with 103 stridulatory pegs on inner side and epiphallus with indistinct projection on inner side of lateral plates. Type specimens are deposited in the Shanghai Entomological Museum, Chinese Academy of Sciences, Shanghai, 200032, China.

  2. Comparison of in vivo eccentricity and symmetry indices between metallic stents and bioresorbable vascular scaffolds: insights from the ABSORB and SPIRIT trials.

    PubMed

    Brugaletta, Salvatore; Gomez-Lara, Josep; Diletti, Roberto; Farooq, Vasim; van Geuns, Robert Jan; de Bruyne, Bernard; Dudek, Dariusz; Garcia-Garcia, Hector M; Ormiston, John A; Serruys, Patrick W

    2012-02-01

    To compare the geometrical parameters of a bioresorbable vascular scaffold (BVS) with a standard metallic stent. The introduction of polymeric bioresorbable materials in the design of novel coronary scaffolds may affect some geometrical parameters, such as eccentricity and symmetry indices, previously introduced as IVUS criteria for optimal metallic stent deployment. From ABSORB Cohort A, ABSORB Cohort B, SPIRIT I, and SPIRIT II, all patients implanted with BVS 1.0, BVS 1.1, or XIENCE V, respectively and intravascular ultrasound analyses post-implantation were selected. The eccentricity index was calculated frame by frame and expressed as an average per device (minimum diameter/maximum diameter). The symmetry index of the device was reported as ([maximum diameter - minimum diameter]/maximum diameter). Six months major adverse cardiac events (MACE) were analyzed. A total of 242 patients were selected (BVS 1.0: n = 28, BVS 1.1: n = 94, XIENCE V: n = 120). The BVS exhibited a significantly lower eccentricity index (BVS 1.0: 0.83 ± 0.09; BVS 1.1: 0.85 ± 0.08; XIENCE V: 0.90 ± 0.06; P < 0.01) and a significantly higher symmetry index (BVS 1.0: 0.30 ± 0.07; BVS 1.1: 0.31 ± 0.06, XIENCE V 0.26 ± 0.07; P < 0.01) as compared to the XIENCE V. An inverse correlation was found between the symmetry and eccentricity indices for both (BVS r = -0.69, P < 0.01; XIENCE V r = -0.61, P < 0.01). No differences in MACE were detected between the groups according to their geometrical parameters. The introduction of a new polymeric material in the design of BVS resulted in a lower eccentricity index and a higher symmetry index as compared to metallic stents, without detectable impact in MACE, at 6 months. Copyright © 2011 Wiley Periodicals, Inc.

  3. Efficacy of losartan vs. atenolol for the prevention of aortic dilation in Marfan syndrome: a randomized clinical trial.

    PubMed

    Forteza, Alberto; Evangelista, Arturo; Sánchez, Violeta; Teixidó-Turà, Gisela; Sanz, Paz; Gutiérrez, Laura; Gracia, Teresa; Centeno, Jorge; Rodríguez-Palomares, José; Rufilanchas, Juan Jose; Cortina, José; Ferreira-González, Ignacio; García-Dorado, David

    2016-03-21

    To determine the efficacy of losartan vs. atenolol in aortic dilation progression in Marfan syndrome (MFS) patients. A phase IIIb, randomized, parallel, double-blind study was conducted in 140 MFS patients, age range: 5-60 years, with maximum aortic diameter <45 mm who received losartan (n = 70) or atenolol (n = 70). Doses were raised to a maximum of 1.4 mg/kg/day or 100 mg/day. The primary end-point was the change in aortic root and ascending aorta maximum diameter indexed by body surface area on magnetic resonance imaging after 36 months of treatment. No serious drug-related adverse effects were observed. Five patients presented aortic events during a follow-up (one in the losartan and four in the atenolol groups, P = 0.366). After 3 years of follow-up, aortic root diameter increased significantly in both groups: 1.1 mm (95% CI 0.6-1.6) in the losartan and 1.4 mm (95% CI 0.9-1.9) in the atenolol group, with aortic dilatation progression being similar in both groups: absolute difference between losartan and atenolol -0.3 mm (95% CI -1.1 to 0.4, P = 0.382) and indexed by BSA -0.5 mm/m2 (95% CI -1.2 to 0.1, P = 0.092). Similarly, no significant differences were found in indexed ascending aorta diameter changes between the losartan and atenolol groups: -0.3 mm/m2 (95% CI -0.8 to 0.3, P = 0.326). Among patients with MFS, the use of losartan compared with atenolol did not result in significant differences in the progression of aortic root and ascending aorta diameters over 3 years of follow-up. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  4. Particle sizing by weighted measurements of scattered light

    NASA Technical Reports Server (NTRS)

    Buchele, Donald R.

    1988-01-01

    A description is given of a measurement method, applicable to a poly-dispersion of particles, in which the intensity of scattered light at any angle is weighted by a factor proportional to that angle. Determination is then made of four angles at which the weighted intensity is four fractions of the maximum intensity. These yield four characteristic diameters, i.e., the diameters of the volume/area mean (D sub 32 the Sauter mean) and the volume/diameter mean (D sub 31); the diameters at cumulative volume fractions of 0.5 (D sub v0.5 the volume median) and 0.75 (D sub v0.75). They also yield the volume dispersion of diameters. Mie scattering computations show that an average diameter less than three micrometers cannot be accurately measured. The results are relatively insensitive to extraneous background light and to the nature of the diameter distribution. Also described is an experimental method of verifying the conclusions by using two microscopic slides coated with polystyrene microspheres to simulate the particles and the background.

  5. Simple broadband implementation of a phase contrast wavefront sensor for adaptive optics

    NASA Technical Reports Server (NTRS)

    Bloemhof, E. E.; Wallace, J. K.

    2004-01-01

    The most critical element of an adaptive optics system is its wavefront sensor, which must measure the closed-loop difference between the corrected wavefront and an ideal template at high speed, in real time, over a dense sampling of the pupil. Most high-order systems have used Shack-Hartmann wavefront sensors, but a novel approach based on Zernike's phase contrast principle appears promising. In this paper we discuss a simple way to achromatize such a phase contrast wavefront sensor, using the pi/2 phase difference between reflected and transmitted rays in a thin, symmetric beam splitter. We further model the response at a range of wavelengths to show that the required transverse dimension of the focal-plane phase-shifting spot, nominally lambda/D, may not be very sensitive to wavelength, and so in practice additional optics to introduce wavelength-dependent transverse magnification achromatizing this spot diameter may not be required. A very simple broadband implementation of the phase contrast wavefront sensor results.

  6. Analytical models for use in fan inflow control structure design. Inflow distortion and acoustic transmission models

    NASA Technical Reports Server (NTRS)

    Gedge, M. R.

    1979-01-01

    Analytical models were developed to study the effect of flow contraction and screening on inflow distortions to identify qualitative design criteria. Results of the study are that: (1) static testing distortions are due to atmospheric turbulence, nacelle boundary layer, exhaust flow reingestion, flow over stand, ground plane, and engine casing; (2) flow contraction suppresses, initially, turbulent axial velocity distortions and magnifies turbulent transverse velocity distortions; (3) perforated plate and gauze screens suppress axial components of velocity distortions to a degree determined by the screen pressure loss coefficient; (4) honeycomb screen suppress transverse components of velocity distortions to a degree determined by the length to diameter ratio of the honeycomb; (5) acoustic transmission loss of perforated plate is controlled by the reactance of its acoustic impedance; (6) acoustic transmission loss of honeycomb screens is negligible; and (7) a model for the direction change due to a corner between honeycomb panels compares favorably with measured data.

  7. In vivo correlation mapping microscopy

    NASA Astrophysics Data System (ADS)

    McGrath, James; Alexandrov, Sergey; Owens, Peter; Subhash, Hrebesh; Leahy, Martin

    2016-04-01

    To facilitate regular assessment of the microcirculation in vivo, noninvasive imaging techniques such as nailfold capillaroscopy are required in clinics. Recently, a correlation mapping technique has been applied to optical coherence tomography (OCT), which extends the capabilities of OCT to microcirculation morphology imaging. This technique, known as correlation mapping optical coherence tomography, has been shown to extract parameters, such as capillary density and vessel diameter, and key clinical markers associated with early changes in microvascular diseases. However, OCT has limited spatial resolution in both the transverse and depth directions. Here, we extend this correlation mapping technique to other microscopy modalities, including confocal microscopy, and take advantage of the higher spatial resolution offered by these modalities. The technique is achieved as a processing step on microscopy images and does not require any modification to the microscope hardware. Results are presented which show that this correlation mapping microscopy technique can extend the capabilities of conventional microscopy to enable mapping of vascular networks in vivo with high spatial resolution in both the transverse and depth directions.

  8. Photoelectron yields of scintillation counters with embedded wavelength-shifting fibers read out with silicon photomultipliers

    NASA Astrophysics Data System (ADS)

    Artikov, Akram; Baranov, Vladimir; Blazey, Gerald C.; Chen, Ningshun; Chokheli, Davit; Davydov, Yuri; Dukes, E. Craig; Dychkant, Alexsander; Ehrlich, Ralf; Francis, Kurt; Frank, M. J.; Glagolev, Vladimir; Group, Craig; Hansen, Sten; Magill, Stephen; Oksuzian, Yuri; Pla-Dalmau, Anna; Rubinov, Paul; Simonenko, Aleksandr; Song, Enhao; Stetzler, Steven; Wu, Yongyi; Uzunyan, Sergey; Zutshi, Vishnu

    2018-05-01

    Photoelectron yields of extruded scintillation counters with titanium dioxide coating and embedded wavelength shifting fibers read out by silicon photomultipliers have been measured at the Fermilab Test Beam Facility using 120 GeV protons. The yields were measured as a function of transverse, longitudinal, and angular positions for a variety of scintillator compositions, reflective coating mixtures, and fiber diameters. Timing performance was also studied. These studies were carried out by the Cosmic Ray Veto Group of the Mu2e collaboration as part of their R&D program.

  9. A novel modeling to predict the critical current behavior of Nb3Sn PIT strand under transverse load based on a scaling law and Finite Element Analysis

    NASA Astrophysics Data System (ADS)

    Wang, Tiening; Chiesa, Luisa; Takayasu, Makoto; Bordini, Bernardo

    2014-09-01

    Superconducting Nb3Sn Powder-In-Tube (PIT) strands could be used for the superconducting magnets of the next generation Large Hadron Collider. The strands are cabled into the typical flat Rutherford cable configuration. During the assembly of a magnet and its operation the strands experience not only longitudinal but also transverse load due to the pre-compression applied during the assembly and the Lorentz load felt when the magnets are energized. To properly design the magnets and guarantee their safe operation, mechanical load effects on the strand superconducting properties are studied extensively; particularly, many scaling laws based on tensile load experiments have been established to predict the critical current dependence on strain. However, the dependence of the superconducting properties on transverse load has not been extensively studied so far. One of the reasons is that transverse loading experiments are difficult to conduct due to the small diameter of the strand (about 1 mm) and the data currently available do not follow a common measurement standard making the comparison between different data sets difficult. Recently at the University of Geneva, a new device has been developed to characterize the critical current of Nb3Sn strands under transverse loads. In this work we present a new 2D Finite Element Analysis (FEA) to predict the electro-mechanical response of a PIT strand that was tested at the University of Geneva when transverse load is applied. The FEA provides the strain map for the superconducting filaments when the load is applied. Those strain maps are then used to evaluate the critical current behavior of a PIT strand using a recently developed scaling law that correlates the superconducting properties of a wire with the strain invariants due to the load applied on the superconductor. The benefits and limitations of this method are discussed based on the comparison between the critical current simulation results obtained with the filament strain map and the experimental results available for PIT strands.

  10. Erosion and sediment yields in the Transverse Ranges, Southern California

    USGS Publications Warehouse

    Scott, Kevin M.; Williams, Rhea P.

    1978-01-01

    Major-storm and long-term erosion rates in mountain watersheds of the western Transverse Ranges of Ventura County, Calif., are estimated to range from low values that would not require the construction of catchments or channel-stabilization structures to values as high as those recorded anywhere for comparable bedrock erodibilities. A major reason for this extreme variability is the high degree of tectonic activity in the area--watersheds are locally being uplifted by at least as much as 25 feet per 1,000 years, yet the maximum extrapolated rate of denudation measured over the longest available period of record is 7.5 feet per 1,000 years adjusted to a drainage area of 0.5 square mile. Evidence of large amounts of uplift continuing into historic time includes structurally overturned strata of Pleistocene age, active thrust faulting, demonstrable stream antecedence, uplifted and deformed terraces, and other results of base-level change seen in stream channels. Such evidence is widespread in the Transverse Ranges, and aspects of the landscape are locally more a function of tectonic activity than of the denudational process. (Woodard-USGS)

  11. Biomechanical comparison of straight and helical compression plates for fixation of transverse and oblique bone fractures: Modeling and experiments.

    PubMed

    Sezek, Sinan; Aksakal, Bunyamin; Gürger, Murat; Malkoc, Melih; Say, Y

    2016-08-12

    Total deformation and stability of straight and helical compression plates were studied by means of the finite element method (FEM) and in vitro biomechanical experiments. Fixations of transverse (TF) and oblique (45°) bone (OF) fractures have been analyzed on sheep tibias by designing the straight compression (SP) and Helical Compression Plate (HP) models. The effects of axial compression, bending and torsion loads on both plating systems were analyzed in terms of total displacements. Numerical models and experimental models suggested that under compression loadings, bone fracture gap closures for both fracture types were found to be in the favor of helical plate designs. The helical plate (HP) fixations provided maximum torsional resistance compared to the (SP) fixations. The fracture gap closure and stability of helical plate fixation for transverse fractures was determined to be higher than that found for the oblique fractures. The comparison of average compression stress, bending and torsion moments showed that the FEM and experimental results are in good agreement and such designs are likely to have a positive impact in future bone fracture fixation designs.

  12. Design of a transverse-flux permanent-magnet linear generator and controller for use with a free-piston stirling engine

    NASA Astrophysics Data System (ADS)

    Zheng, Jigui; Huang, Yuping; Wu, Hongxing; Zheng, Ping

    2016-07-01

    Transverse-flux with high efficiency has been applied in Stirling engine and permanent magnet synchronous linear generator system, however it is restricted for large application because of low and complex process. A novel type of cylindrical, non-overlapping, transverse-flux, and permanent-magnet linear motor(TFPLM) is investigated, furthermore, a high power factor and less process complexity structure research is developed. The impact of magnetic leakage factor on power factor is discussed, by using the Finite Element Analysis(FEA) model of stirling engine and TFPLM, an optimization method for electro-magnetic design of TFPLM is proposed based on magnetic leakage factor. The relation between power factor and structure parameter is investigated, and a structure parameter optimization method is proposed taking power factor maximum as a goal. At last, the test bench is founded, starting experimental and generating experimental are performed, and a good agreement of simulation and experimental is achieved. The power factor is improved and the process complexity is decreased. This research provides the instruction to design high-power factor permanent-magnet linear generator.

  13. Birth, growth and death of an antivortex during the propagation of a transverse domain wall in magnetic nanostrips

    NASA Astrophysics Data System (ADS)

    Yuan, H. Y.; Wang, X. R.

    2014-11-01

    Antivortex birth, growth and death accompanying the propagation of a transverse domain wall (DW) in magnetic nanostrips are observed and analyzed. Antivortex formation is an intrinsic process of a strawberry-like transverse DW originated from magnetostatic interaction. Under an external magnetic field, the wider width region of a DW tends to move faster than the narrower one. This speed mismatch tilts and elongates DW center line. As a result, an antivortex with a well-defined polarity is periodically born near the tail of the DW center line. The antivortex either moves along the center line and dies on the other side of the nanostrip, or grows to its maximum size, detaches itself from the DW, and vanishes eventually. The former route reverses the polarity of DW while the later keeps the DW polarity unchanged. The evolution of the DW structures is analyzed using winding numbers assigned to each topological defects. The phase diagram in the field-width plane is obtained and the damping constant's influence on the phase diagram is discussed.

  14. Variation and Heritability in Hair Diameter and Curvature in an Australian Twin Sample.

    PubMed

    Ho, Yvonne Y W; Brims, Mark; McNevin, Dennis; Spector, Timothy D; Martin, Nicholas G; Medland, Sarah E

    2016-08-01

    Hair diameter and curvature are two characteristics of human scalp hair used in forensic contexts. While previous data show that subjective categorization of hair curvature is highly heritable, the heritability of objectively measured curvature and diameter, and variability of hair characteristics within each individual have not yet been studied. The present study measured hair diameter and curvature using an optical fiber diameter analyzer in a sample of 2,332 twins and siblings. Heritability was estimated using maximum likelihood structural equation modeling. Results show sex differences in the magnitude of genetic influence for mean diameter and curvature, with the vast majority of the variance accounted for by genetic effects in males (diameter = 86%, curvature = 53%) and females (diameter = 77%, curvature = 61%). The consistency of diameter (variance within an individual) was also highly heritable, but did not show sex limitation, with 68% of the variance accounted for by genetic factors. Moderate phenotypic correlations were seen between diameter and consistency (r = 0.3) but there was little correlation between diameter and curvature (r = -0.13). A bivariate Cholesky analysis was used to estimate the genetic and environmental correlations between hair diameter and consistency, yielding genetic correlations of r gF = 0.27 for females and r gM = 0.25 for males.

  15. Biomechanical Comparison of External Fixation and Compression Screws for Transverse Tarsal Joint Arthrodesis.

    PubMed

    Latt, L Daniel; Glisson, Richard R; Adams, Samuel B; Schuh, Reinhard; Narron, John A; Easley, Mark E

    2015-10-01

    Transverse tarsal joint arthrodesis is commonly performed in the operative treatment of hindfoot arthritis and acquired flatfoot deformity. While fixation is typically achieved using screws, failure to obtain and maintain joint compression sometimes occurs, potentially leading to nonunion. External fixation is an alternate method of achieving arthrodesis site compression and has the advantage of allowing postoperative compression adjustment when necessary. However, its performance relative to standard screw fixation has not been quantified in this application. We hypothesized that external fixation could provide transverse tarsal joint compression exceeding that possible with screw fixation. Transverse tarsal joint fixation was performed sequentially, first with a circular external fixator and then with compression screws, on 9 fresh-frozen cadaveric legs. The external fixator was attached in abutting rings fixed to the tibia and the hindfoot and a third anterior ring parallel to the hindfoot ring using transverse wires and half-pins in the tibial diaphysis, calcaneus, and metatarsals. Screw fixation comprised two 4.3 mm headless compression screws traversing the talonavicular joint and 1 across the calcaneocuboid joint. Compressive forces generated during incremental fixator foot ring displacement to 20 mm and incremental screw tightening were measured using a custom-fabricated instrumented miniature external fixator spanning the transverse tarsal joint. The maximum compressive force generated by the external fixator averaged 186% of that produced by the screws (range, 104%-391%). Fixator compression surpassed that obtainable with screws at 12 mm of ring displacement and decreased when the tibial ring was detached. No correlation was found between bone density and the compressive force achievable by either fusion method. The compression across the transverse tarsal joint that can be obtained with a circular external fixator including a tibial ring exceeds that which can be obtained with 3 headless compression screws. Screw and external fixator performance did not correlate with bone mineral density. This study supports the use of external fixation as an alternative method of generating compression to help stimulate fusion across the transverse tarsal joints. The findings provide biomechanical evidence to support the use of external fixation as a viable option in transverse tarsal joint fusion cases in which screw fixation has failed or is anticipated to be inadequate due to suboptimal bone quality. © The Author(s) 2015.

  16. Generation of High-Power High-Intensity Short X-Ray Free-Electron-Laser Pulses

    DOE PAGES

    Guetg, Marc W.; Lutman, Alberto A.; Ding, Yuantao; ...

    2018-01-03

    X-ray free-electron lasers combine a high pulse power, short pulse length, narrow bandwidth, and high degree of transverse coherence. Any increase in the photon pulse power, while shortening the pulse length, will further push the frontier on several key x-ray free-electron laser applications including single-molecule imaging and novel nonlinear x-ray methods. This Letter shows experimental results at the Linac Coherent Light Source raising its maximum power to more than 300% of the current limit while reducing the photon pulse length to 10 fs. As a result, this was achieved by minimizing residual transverse-longitudinal centroid beam offsets and beam yaw andmore » by correcting the dispersion when operating over 6 kA peak current with a longitudinally shaped beam.« less

  17. The transverse magnetic field effect on steady-state solutions of the Bursian diode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pramanik, Sourav; Chakrabarti, Nikhil; Ender, A. Ya.

    2015-04-15

    A study of steady-states of a planar vacuum diode driven by a cold electron beam (the Bursian diode) under an external transverse magnetic field is presented. The regime of no electrons turned around by a magnetic field only is under the consideration. The emitter electric field is evaluated as a characteristic function for the existence of solutions depending on the diode length, the applied voltage, and the magnetic field strength. At certain conditions, it is shown that a region of non-unique solutions exists in the Bursian diode when the magnetic field is absent. An expression for the maximum current transmittedmore » through the diode is derived. The external magnetic field is put forth to control fast electronic switches based on the Bursian diode.« less

  18. Generation of High-Power High-Intensity Short X-Ray Free-Electron-Laser Pulses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guetg, Marc W.; Lutman, Alberto A.; Ding, Yuantao

    X-ray free-electron lasers combine a high pulse power, short pulse length, narrow bandwidth, and high degree of transverse coherence. Any increase in the photon pulse power, while shortening the pulse length, will further push the frontier on several key x-ray free-electron laser applications including single-molecule imaging and novel nonlinear x-ray methods. This Letter shows experimental results at the Linac Coherent Light Source raising its maximum power to more than 300% of the current limit while reducing the photon pulse length to 10 fs. As a result, this was achieved by minimizing residual transverse-longitudinal centroid beam offsets and beam yaw andmore » by correcting the dispersion when operating over 6 kA peak current with a longitudinally shaped beam.« less

  19. Flare research with the NASA/MSFC vector magnetograph - Observed characteristics of sheared magnetic fields that produce flares

    NASA Technical Reports Server (NTRS)

    Moore, R. L.; Hagyard, M. J.; Davis, J. M.

    1987-01-01

    The present MSFC Vector Magnetograph has sufficient spatial resolution (2.7 arcsec pixels) and sensitivity to the transverse field (the noise level is about 100 gauss) to map the transverse field in active regions accurately enough to reveal key aspects of the sheared magnetic fields commonly found at flare sites. From the measured shear angle along the polarity inversion line in sites that flared and in other shear sites that didn't flare, evidence is found that a sufficient condition for a flare to occur in 1000 gauss fields in and near sunspots is that both: (1) the maximum shear angle exceed 85 degrees; and (2) the extent of strong shear (shear angle of greater than 80 degrees) exceed 10,000 km.

  20. Sharpening of carbon nanocone tips during plasma-enhanced chemical vapor growth

    NASA Astrophysics Data System (ADS)

    Merkulov, Vladimir I.; Melechko, Anatoli V.; Guillorn, Michael A.; Lowndes, Douglas H.; Simpson, Michael L.

    2001-12-01

    In situ tip sharpening of vertically aligned carbon nanocones (VACNCs) was demonstrated. VACNCs were synthesized on patterned catalyst dots of 100 nm in diameter using dc plasma-enhanced chemical vapor deposition. The VACNC tip diameter was found to decrease with growth time. This enables synthesis of ultra-sharp VACNCs even for relatively large catalyst dot sizes, which is quite important for practical applications. We also find that for a given set of growth parameters the diameter of the initially formed catalyst nanoparticle determines the maximum length of the growing VACNC. The mechanism of VACNC growth and sharpening is discussed.

  1. Common iliac artery aneurysms in patients with abdominal aortic aneurysms.

    PubMed

    Armon, M P; Wenham, P W; Whitaker, S C; Gregson, R H; Hopkinson, B R

    1998-03-01

    To determine the incidence of common iliac artery (CIA) aneurysms in patients with abdominal aortic aneurysms (AAA) and to evaluate the relationship between AAA and CIA diameter. Spiral CT angiography was used to measure the maximum diameters of the abdominal aorta and the common iliac arteries of 215 patients with AAA. The median CIA diameter was 1.7 cm--significantly greater than the published mean of 1.25 (2 S.D. = 0.85-1.65) cm of an age-matched, non-vascular population. Thirty-four patients (16%) had unilateral and 26 patients (12%) bilateral CIA aneurysms > or = 2.4 cm diameter. Eight-six vessels (20%) were affected. Right CIA diameters were wider than left CIA diameters (p < 0.0001, Wilcoxon matched-pairs signed rank test). The correlation between AAA size and CIA diameter was weak. The AAA population has abnormally dilated common iliac arteries. In this population, common iliac artery aneurysms should be defined as those greater than 2.4 cm diameter. 20% of CIAs in patients with AAA are aneurysmal according to this definition.

  2. NOLIN: A nonlinear laminate analysis program

    NASA Technical Reports Server (NTRS)

    Kibler, J. J.

    1975-01-01

    A nonlinear, plane-stress, laminate analysis program, NOLIN, was developed which accounts for laminae nonlinearity under inplane shear and transverse extensional stress. The program determines the nonlinear stress-strain behavior of symmetric laminates subjected to any combination of inplane shear and biaxial extensional loadings. The program has the ability to treat different stress-strain behavior in tension and compression, and predicts laminate failure using any or all of maximum stress, maximum strain, and quadratic interaction failure criteria. A brief description of the program is presented including discussion of the flow of information and details of the input required. Sample problems and a complete listing of the program is also provided.

  3. A bi-prism interferometer for hard x-ray photons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Isakovic, A.F.; Siddons, D.; Stein, A.

    2010-04-06

    Micro-fabricated bi-prisms have been used to create an interference pattern from an incident hard X-ray beam, and the intensity of the pattern probed with fluorescence from a 30 nm-thick metal film. Maximum fringe visibility exceeded 0.9 owing to the nano-sized probe and the choice of single-crystal prism material. A full near-field analysis is necessary to describe the fringe field intensities, and the transverse coherence lengths were extracted at APS beamline 8-ID-I. It is also shown that the maximum number of fringes is dependent only on the complex refractive index of the prism material.

  4. Viscoelastic/damage modeling of filament-wound spherical pressure vessels

    NASA Technical Reports Server (NTRS)

    Hackett, Robert M.; Dozier, Jan D.

    1987-01-01

    A model of the viscoelastic/damage response of a filament-wound spherical vessel used for long-term pressure containment is developed. The matrix material of the composite system is assumed to be linearly viscoelastic. Internal accumulated damage based upon a quadratic relationship between transverse modulus and maximum circumferential strain is postulated. The resulting nonlinear problem is solved by an iterative routine. The elastic-viscoelastic correspondence is employed to produce, in the Laplace domain, the associated elastic solution for the maximum circumferential strain which is inverted by the method of collocation to yield the time-dependent solution. Results obtained with the model are compared to experimental observations.

  5. 77 FR 15798 - Notice of Intent To Repatriate Cultural Items: San Francisco State University, San Francisco, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-16

    ... height and 10.5 cm in diameter and is made of deer grass, sedge, redbud and bracken fern root. There are... deer grass, saw grass, redbud and bracken fern root. A tag attached to the basket was labeled... height with a maximum diameter of 18 cm and is made of deer grass, sedge, redbud and bracken fern root. A...

  6. Power consumption analysis DBD plasma ozone generator

    NASA Astrophysics Data System (ADS)

    Nur, M.; Restiwijaya, M.; Muchlisin, Z.; Susan, I. A.; Arianto, F.; Widyanto, S. A.

    2016-11-01

    Studies on the consumption of energy by an ozone generator with various constructions electrodes of dielectric barrier discharge plasma (DBDP) reactor has been carried out. This research was done to get the configuration of the reactor, that is capable to produce high ozone concentrations with low energy consumption. BDBP reactors were constructed by spiral- cylindrical configuration, plasma ozone was generated by high voltage AC voltage up to 25 kV and maximum frequency of 23 kHz. The reactor consists of an active electrode in the form of a spiral-shaped with variation diameter Dc, and it was made by using copper wire with diameter Dw. In this research, we variated number of loops coil windings N as well as Dc and Dw. Ozone concentrations greater when the wire's diameter Dw and the diameter of the coil windings applied was greater. We found that impedance greater will minimize the concentration of ozone, in contrary to the greater capacitance will increase the concentration of ozone. The ozone concentrations increase with augmenting of power. Maximum power is effective at DBD reactor spiral-cylinder is on the Dc = 20 mm, Dw = 1.2 mm, and the number of coil windings N = 10 loops with the resulting concentration is greater than 20 ppm and it consumes energy of 177.60 watts

  7. Design of a multifiber light delivery system for photoacoustic-guided surgery.

    PubMed

    Eddins, Blackberrie; Bell, Muyinatu A Lediju

    2017-04-01

    This work explores light delivery optimization for photoacoustic-guided minimally invasive surgeries, such as the endonasal transsphenoidal approach. Monte Carlo simulations were employed to study three-dimensional light propagation in tissue, comprising one or two 4-mm diameter arteries located 3 mm below bone, an absorbing metallic drill contacting the bone surface, and a single light source placed next to the 2.4-mm diameter drill shaft with a 2.9-mm diameter spherical drill tip. The optimal fiber distance from the drill shaft was determined from the maximum normalized fluence to the underlying artery. Using this optimal fiber-to-drill shaft distance, Zemax simulations were employed to propagate Gaussian beams through one or more 600 micron-core diameter optical fibers for detection on the bone surface. When the number of equally spaced fibers surrounding the drill increased, a single merged optical profile formed with seven or more fibers, determined by thresholding the resulting light profile images at 1 / e times the maximum intensity. We used these simulations to inform design requirements, build a one to seven multifiber light delivery prototype to surround a surgical drill, and demonstrate its ability to simultaneously visualize the tool tip and blood vessel targets in the absence and presence of bone. The results and methodology are generalizable to multiple interventional photoacoustic applications.

  8. Nonhuman Primate Ocular Biometry

    PubMed Central

    Augusteyn, Robert C.; Maceo Heilman, Bianca; Ho, Arthur; Parel, Jean-Marie

    2016-01-01

    Purpose To examine ocular growth in nonhuman primates (NHPs) from measurements on ex vivo eyes. Methods We obtained NHP eyes from animals that had been killed as part of other studies or because of health-related issues. Digital calipers were used to measure the horizontal, vertical, and anteroposterior globe diameters as well as corneal horizontal and vertical diameters of excised globes from 98 hamadryas baboons, 551 cynomolgus monkeys, and 112 rhesus monkeys, at ages ranging from 23 to 360 months. Isolated lens sagittal thickness and equatorial diameter were measured by shadowphotogrammetry. Wet and fixed dry weights were obtained for lenses. Results Nonhuman primate globe growth continues throughout life, slowing toward an asymptotic maximum. The final globe size scales with negative allometry to adult body size. Corneal growth ceases at around 20 months. Lens diameter increases but thickness decreases with increasing age. Nonhuman primate lens wet and dry weight accumulation is monophasic, continuing throughout life toward asymptotic maxima. The dry/wet weight ratio reaches a maximum of 0.33. Conclusions Nonhuman primate ocular globe and lens growth differ in several respects from those in humans. Although age-related losses of lens power and accommodative amplitude are similar, lens growth and properties are different indicating care should be taken in extrapolating NHP observations to the study of human accommodation. PMID:26780314

  9. Design of a multifiber light delivery system for photoacoustic-guided surgery

    NASA Astrophysics Data System (ADS)

    Eddins, Blackberrie; Bell, Muyinatu A. Lediju

    2017-04-01

    This work explores light delivery optimization for photoacoustic-guided minimally invasive surgeries, such as the endonasal transsphenoidal approach. Monte Carlo simulations were employed to study three-dimensional light propagation in tissue, comprising one or two 4-mm diameter arteries located 3 mm below bone, an absorbing metallic drill contacting the bone surface, and a single light source placed next to the 2.4-mm diameter drill shaft with a 2.9-mm diameter spherical drill tip. The optimal fiber distance from the drill shaft was determined from the maximum normalized fluence to the underlying artery. Using this optimal fiber-to-drill shaft distance, Zemax simulations were employed to propagate Gaussian beams through one or more 600 micron-core diameter optical fibers for detection on the bone surface. When the number of equally spaced fibers surrounding the drill increased, a single merged optical profile formed with seven or more fibers, determined by thresholding the resulting light profile images at 1/e times the maximum intensity. We used these simulations to inform design requirements, build a one to seven multifiber light delivery prototype to surround a surgical drill, and demonstrate its ability to simultaneously visualize the tool tip and blood vessel targets in the absence and presence of bone. The results and methodology are generalizable to multiple interventional photoacoustic applications.

  10. Estimating tree crown widths for the primary Acadian species in Maine

    Treesearch

    Matthew B. Russell; Aaron R. Weiskittel

    2012-01-01

    In this analysis, data for seven conifer and eight hardwood species were gathered from across the state of Maine for estimating tree crown widths. Maximum and largest crown width equations were developed using tree diameter at breast height as the primary predicting variable. Quantile regression techniques were used to estimate the maximum crown width and a constrained...

  11. Determining maximum stand density index in mixed species stands for strategic-scale stocking assessments

    Treesearch

    Chris W. Woodall; Patrick D. Miles; John S. Vissage

    2005-01-01

    Stand density index (SDI), although developed for use in even-aged monocultures, has been used for assessing stand density in large-scale forest inventories containing diverse tree species and size distributions. To improve application of SDI in unevenaged, mixed species stands present in large-scale forest inventories, trends in maximum SDI across diameter classes...

  12. Assessment of sex in a modern Turkish population using cranial anthropometric parameters.

    PubMed

    Ekizoglu, Oguzhan; Hocaoglu, Elif; Inci, Ercan; Can, Ismail Ozgur; Solmaz, Dilek; Aksoy, Sema; Buran, Cudi Ferat; Sayin, Ibrahim

    2016-07-01

    The utilization of radiological imaging methods in anthropometric studies is being expanded by the application of modern imaging methods, leading to a decrease in costs, a decrease in the time required for analysis and the ability to create three-dimensional images. This retrospective study investigated 400 patients within the 18-45-years age group (mean age: 30.7±11.2years) using cranial computed tomography images. We measured 14 anthropometric parameters (basion-bregma height, basion-prosthion length, maximum cranial length and cranial base lengths, maximum cranial breadth, bizygomatic diameter, upper facial breadth, bimastoid diameter, orbital breadth, orbital length, biorbital breadth, interorbital breadth, foramen magnum breadth and foramen magnum length) of cranial measurements. The intra- and inter-observer repeatability and consistency were good. From the results of logistic regression analysis using morphometric measurements, the most conspicuous measurements in terms of dimorphism were maximum cranial length, bizygomatic diameter, basion-bregma height, and cranial base length. The most dimorphic structure was the bizygomatic diameter with an accuracy rate of 83% in females and 77% in males. In this study, 87.5% of females and 87.0% of males were classified accurately by this model including four parameters with a sensitivity of 91.5% and specificity of 85.0%. In conclusion, CT cranial morphometric analysis may be reliable for the assessment of sex in the Turkish population and is recommended for comparison of data of modern populations with those of former populations. Additionally, cranial morphometric data that we obtained from modern Turkish population may reveal population specific data, which may help current criminal investigations and identification of disaster victims. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Sonographic aorta/IVC cross-sectional area index for evaluation of dehydration in children.

    PubMed

    Kwon, Hyuksool; Jung, Jae Yun; Lee, Jin Hee; Kwak, Young Ho; Kim, Do Kyun; Jung, Jin Hee; Chang, Ik Wan; Kim, Kyuseok

    2016-09-01

    Current studies have not found sufficient evidence to encourage the use of ultrasound for assessing dehydration in children. We introduce a new sonographic parameter, the "aorta/inferior vena cava (IVC) cross-sectional area index" (Ao/IVCA) measured just inferior to the xiphoid process, for the effective evaluation of dehydration in children. This is a prospective, observational study. We enrolled children who presented to the pediatric emergency department (PED) between May 2014 and January 2015. We measured the maximum diameter of the aorta from inner wall to inner wall, and the long and short axis diameters of IVC using a convex array transducer. Ao/IVCA was calculated and compared with aorta/IVC maximal diameter index (Ao/IVCD) and the clinical dehydration scale (CDS). A total of 34 children were enrolled. We found a statistically significant correlation between Ao/IVCA and CDS (R(2) = 0.30; P <.001). Ao/IVCD did not correlate significantly with CDS (R(2) = 0.08; P =.11). The ability of Ao/IVCA and Ao/IVCD to predict CDS ≥1 was assessed using the receiver operating characteristic analysis. The area under the receiver operating characteristic curve for Ao/IVCA was larger than that for Ao/IVCD (0.87 vs 0.75, P= .04). The cut-off value of Ao/IVCA that yielded the maximum value of Youden index was 1.81 (sensitivity: 72%, specificity: 89%). Ao/IVCA might be a promising index for the assessment of dehydration. The diagnostic performance of Ao/IVCA for dehydration might be higher than that of the method that uses the maximum diameter of IVC and the aorta. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. [Evaluation of the diagnosis of subclinical endometritis in dairy cattle using ultrasound].

    PubMed

    Lenz, Mirjam; Drillich, Marc; Heuwieser, Wolfgang

    2007-01-01

    The aim of this study was to determine signs of subclinical endometritis found by ultrasound that are associated with reduced fertility in dairy cows. The maximum diameter of the uterine lumen was determined by ultrasound in 324 cows without clinical signs of endometritis after evaluation of the genital tract 21 to 27 days postpartum. Cows were classified into healthy or with subclinical endometritis by three threshold values for the maximum uterine lumen diameter of 0.2 cm, 0.5 cm or 0.8 cm. Examinations by rectal palpation and ultrasound as well as classifications were repeated 14 days later. In addition, ovaries were scanned by ultrasound to determine the stage of the estrous cycle. In a subgroup of 103 cows the echotexture of the uterus and its contents was evaluated. In these cows the diagnosis of subclinical endometritis was performed by a scoring system. The diameter of the uterine lumen was significantly affected by stage of the estrous cycle at the time of examination. However, no effects were found for the stage of the cycle at the time of examination on subsequent reproductive performance. A uterine lumen with a maximum diameter of more than 0.2 cm showed a significant negative association with conception rate and proportion of cows pregnant. Classification based on higher threshold values did not reveal an association with reproductive performance. Echogenic content in the uterus also decreased reproductive performance. A classification based on the echotexture of the uterus and its contents revealed significant differences between healthy cows and cows with subclinical endometritis regarding the proportion of cows inseminated and pregnant. The results of this study showed that the diagnostic of bovine endometritis should be broadend by ultrasonography. The definition of subclinical endometritis diagnosed by means of ultrasonography has to be evaluated in further studies.

  15. The effect of aortic morphology on peri-operative mortality of ruptured abdominal aortic aneurysm.

    PubMed

    2015-06-01

    To investigate whether aneurysm shape and extent, which indicate whether a patient with ruptured abdominal aortic aneurysm (rAAA) is eligible for endovascular repair (EVAR), influence the outcome of both EVAR and open surgical repair. The influence of six morphological parameters (maximum aortic diameter, aneurysm neck diameter, length and conicality, proximal neck angle, and maximum common iliac diameter) on mortality and reinterventions within 30 days was investigated in rAAA patients randomized before morphological assessment in the Immediate Management of the Patient with Rupture: Open Versus Endovascular strategies (IMPROVE) trial. Patients with a proven diagnosis of rAAA, who underwent repair and had their admission computerized tomography scan submitted to the core laboratory, were included. Among 458 patients (364 men, mean age 76 years), who had either EVAR (n = 177) or open repair (n = 281) started, there were 155 deaths and 88 re-interventions within 30 days of randomization analysed according to a pre-specified plan. The mean maximum aortic diameter was 8.6 cm. There were no substantial correlations between the six morphological variables. Aneurysm neck length was shorter in those undergoing open repair (vs. EVAR). Aneurysm neck length (mean 23.3, SD 16.1 mm) was inversely associated with mortality for open repair and overall: adjusted OR 0.72 (95% CI 0.57, 0.92) for each 16 mm (SD) increase in length. There were no convincing associations of morphological parameters with reinterventions. Short aneurysm necks adversely influence mortality after open repair of rAAA and preclude conventional EVAR. This may help explain why observational studies, but not randomized trials, have shown an early survival benefit for EVAR. ISRCTN 48334791. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.

  16. Development of the monitoring technique on the damage of piles using the biggest shaking table "E-defense"

    NASA Astrophysics Data System (ADS)

    Hayashi, Kazuhiro; Hachimori, Wataru; Kaneda, Shogo; Tamura, Shuji; Saito, Taiki

    2017-10-01

    In case of earthquake damage to buildings, the damage to a superstructure is visible, but the damage to a foundation structure, e.g. the underground pile, is difficult to detect. In this study, the authors aim to develop a monitoring technique for pile damage due to earthquakes. The world's biggest shaking table, E-Defense, was used to reproduce damage to RC pile models embedded in the soil inside a large scale shear box (8m in diameter and 6.5m in height). The diameter of the RC pile model was 154mm. It consisted of mortar (27.2N/mm2 in compressive strength), 6 main reinforcements (6.35mm in diameter) and shear reinforcement hard steel wire (2mm in diameter at intervals of 20mm). The natural period of the superstructure above the pile models is around 0.12sec. The soil consisted of 2 layers. The lower layer is Albany sand of 80% relative density while the upper layer is only 2m from the surface ground and is Kaketsu sand of 60% relative density. Primary four excitations were scaled from JMA Kobe waves in notification at different amplitudes. The maximum acceleration of each wave is 31gal, 67gal, 304gal, and 458gal, respectively. In the test result, reinforcing steels at the pile head of the RC model yielded when the maximum acceleration was 304gal. After that, mortar of the pile head peeled off and a bending shear failure occurred when the maximum acceleration was 458gal. The peak frequency of rotational spectrum on the foundation did not change in elastic range in the piles. However, the peak frequency fell after the plastic hinge occurred.

  17. Fourier Domain Optical Coherence Tomography With 3D and En Face Imaging of the Punctum and Vertical Canaliculus: A Step Toward Establishing a Normative Database.

    PubMed

    Kamal, Saurabh; Ali, Mohammad Javed; Ali, Mohammad Hasnat; Naik, Milind N

    2016-01-01

    To report the features of Fourier domain optical coherence tomography imaging of the normal punctum and vertical canaliculus. Prospective, interventional series of consecutive healthy and asymptomatic adults, who volunteered for optical coherence tomography imaging, were included in the study. Fourier domain optical coherence tomography images of the punctum and vertical canaliculus along with 3D and En face images were captured using the RTVue scanner with a corneal adaptor module and a wide-angled lens. Maximum punctal diameter, mid-canalicular diameter, and vertical canalicular height were calculated. Statistical analysis was performed using Pearson correlation test, and scatter plot matrices were analyzed. A total of 103 puncta of 52 healthy subjects were studied. Although all the images could depict the punctum and vertical canaliculus and all the desired measurements could be obtained, occasional tear debris within the canaliculus was found to be interfering with the imaging. The mean maximum punctal diameter, mid-canalicular diameter, and vertical canalicular height were recorded as 214.71 ± 73 μm, 125.04 ± 60.69 μm, and 890.41 ± 154.76 μm, respectively, with an insignificant correlation between them. The maximum recorded vertical canalicular height in all the cases was far less than the widely reported depth of 2 mm. High-resolution 3D and En face images provided a detailed topography of punctal surface and overview of vertical canaliculus. Fourier domain optical coherence tomography with 3D and En face imaging is a useful noninvasive modality to image the proximal lacrimal system with consistently reproducible high-resolution images. This is likely to help clinicians in the management of proximal lacrimal disorders.

  18. Image processing analysis of nuclear track parameters for CR-39 detector irradiated by thermal neutron

    NASA Astrophysics Data System (ADS)

    Al-Jobouri, Hussain A.; Rajab, Mustafa Y.

    2016-03-01

    CR-39 detector which covered with boric acid (H3Bo3) pellet was irradiated by thermal neutrons from (241Am - 9Be) source with activity 12Ci and neutron flux 105 n. cm-2. s-1. The irradiation times -TD for detector were 4h, 8h, 16h and 24h. Chemical etching solution for detector was sodium hydroxide NaOH, 6.25N with 45 min etching time and 60 C˚ temperature. Images of CR-39 detector after chemical etching were taken from digital camera which connected from optical microscope. MATLAB software version 7.0 was used to image processing. The outputs of image processing of MATLAB software were analyzed and found the following relationships: (a) The irradiation time -TD has behavior linear relationships with following nuclear track parameters: i) total track number - NT ii) maximum track number - MRD (relative to track diameter - DT) at response region range 2.5 µm to 4 µm iii) maximum track number - MD (without depending on track diameter - DT). (b) The irradiation time -TD has behavior logarithmic relationship with maximum track number - MA (without depending on track area - AT). The image processing technique principally track diameter - DT can be take into account to classification of α-particle emitters, In addition to the contribution of these technique in preparation of nano- filters and nano-membrane in nanotechnology fields.

  19. Bayesian, maximum parsimony and UPGMA models for inferring the phylogenies of antelopes using mitochondrial markers.

    PubMed

    Khan, Haseeb A; Arif, Ibrahim A; Bahkali, Ali H; Al Farhan, Ahmad H; Al Homaidan, Ali A

    2008-10-06

    This investigation was aimed to compare the inference of antelope phylogenies resulting from the 16S rRNA, cytochrome-b (cyt-b) and d-loop segments of mitochondrial DNA using three different computational models including Bayesian (BA), maximum parsimony (MP) and unweighted pair group method with arithmetic mean (UPGMA). The respective nucleotide sequences of three Oryx species (Oryx leucoryx, Oryx dammah and Oryx gazella) and an out-group (Addax nasomaculatus) were aligned and subjected to BA, MP and UPGMA models for comparing the topologies of respective phylogenetic trees. The 16S rRNA region possessed the highest frequency of conserved sequences (97.65%) followed by cyt-b (94.22%) and d-loop (87.29%). There were few transitions (2.35%) and none transversions in 16S rRNA as compared to cyt-b (5.61% transitions and 0.17% transversions) and d-loop (11.57% transitions and 1.14% transversions) while comparing the four taxa. All the three mitochondrial segments clearly differentiated the genus Addax from Oryx using the BA or UPGMA models. The topologies of all the gamma-corrected Bayesian trees were identical irrespective of the marker type. The UPGMA trees resulting from 16S rRNA and d-loop sequences were also identical (Oryx dammah grouped with Oryx leucoryx) to Bayesian trees except that the UPGMA tree based on cyt-b showed a slightly different phylogeny (Oryx dammah grouped with Oryx gazella) with a low bootstrap support. However, the MP model failed to differentiate the genus Addax from Oryx. These findings demonstrate the efficiency and robustness of BA and UPGMA methods for phylogenetic analysis of antelopes using mitochondrial markers.

  20. Bayesian, Maximum Parsimony and UPGMA Models for Inferring the Phylogenies of Antelopes Using Mitochondrial Markers

    PubMed Central

    Khan, Haseeb A.; Arif, Ibrahim A.; Bahkali, Ali H.; Al Farhan, Ahmad H.; Al Homaidan, Ali A.

    2008-01-01

    This investigation was aimed to compare the inference of antelope phylogenies resulting from the 16S rRNA, cytochrome-b (cyt-b) and d-loop segments of mitochondrial DNA using three different computational models including Bayesian (BA), maximum parsimony (MP) and unweighted pair group method with arithmetic mean (UPGMA). The respective nucleotide sequences of three Oryx species (Oryx leucoryx, Oryx dammah and Oryx gazella) and an out-group (Addax nasomaculatus) were aligned and subjected to BA, MP and UPGMA models for comparing the topologies of respective phylogenetic trees. The 16S rRNA region possessed the highest frequency of conserved sequences (97.65%) followed by cyt-b (94.22%) and d-loop (87.29%). There were few transitions (2.35%) and none transversions in 16S rRNA as compared to cyt-b (5.61% transitions and 0.17% transversions) and d-loop (11.57% transitions and 1.14% transversions) while comparing the four taxa. All the three mitochondrial segments clearly differentiated the genus Addax from Oryx using the BA or UPGMA models. The topologies of all the gamma-corrected Bayesian trees were identical irrespective of the marker type. The UPGMA trees resulting from 16S rRNA and d-loop sequences were also identical (Oryx dammah grouped with Oryx leucoryx) to Bayesian trees except that the UPGMA tree based on cyt-b showed a slightly different phylogeny (Oryx dammah grouped with Oryx gazella) with a low bootstrap support. However, the MP model failed to differentiate the genus Addax from Oryx. These findings demonstrate the efficiency and robustness of BA and UPGMA methods for phylogenetic analysis of antelopes using mitochondrial markers. PMID:19204824

  1. Transverse Tension Fatigue Life Characterization Through Flexure Testing of Composite Materials

    NASA Technical Reports Server (NTRS)

    OBrien, T. Kevin; Chawan, Arun D.; Krueger, Ronald; Paris, Isabelle

    2001-01-01

    The transverse tension fatigue life of S2/8552 glass-epoxy and IM7/8552 carbon-epoxy was characterized using flexure tests of 90-degree laminates loaded in 3-point and 4-point bending. The influence of specimen polishing and specimen configuration on transverse tension fatigue life was examined using the glass-epoxy laminates. Results showed that 90-degree bend specimens with polished machined edges and polished tension-side surfaces, where bending failures where observed, had lower fatigue lives than unpolished specimens when cyclically loaded at equal stress levels. The influence of specimen thickness and the utility of a Weibull scaling law was examined using the carbon-epoxy laminates. The influence of test frequency on fatigue results was also documented for the 4-point bending configuration. A Weibull scaling law was used to predict the 4-point bending fatigue lives from the 3-point bending curve fit and vice-versa. Scaling was performed based on maximum cyclic stress level as well as fatigue life. The scaling laws based on stress level shifted the curve fit S-N characterizations in the desired direction, however, the magnitude of the shift was not adequate to accurately predict the fatigue lives. Furthermore, the scaling law based on fatigue life shifted the curve fit S-N characterizations in the opposite direction from measured values. Therefore, these scaling laws were not adequate for obtaining accurate predictions of the transverse tension fatigue lives.

  2. Normative biometry of the fetal brain using magnetic resonance imaging.

    PubMed

    Kyriakopoulou, Vanessa; Vatansever, Deniz; Davidson, Alice; Patkee, Prachi; Elkommos, Samia; Chew, Andrew; Martinez-Biarge, Miriam; Hagberg, Bibbi; Damodaram, Mellisa; Allsop, Joanna; Fox, Matt; Hajnal, Joseph V; Rutherford, Mary A

    2017-07-01

    The fetal brain shows accelerated growth in the latter half of gestation, and these changes can be captured by 2D and 3D biometry measurements. The aim of this study was to quantify brain growth in normal fetuses using Magnetic Resonance Imaging (MRI) and to produce reference biometry data and a freely available centile calculator ( https://www.developingbrain.co.uk/fetalcentiles/ ). A total of 127 MRI examinations (1.5 T) of fetuses with a normal brain appearance (21-38 gestational weeks) were included in this study. 2D and 3D biometric parameters were measured from slice-to-volume reconstructed images, including 3D measurements of supratentorial brain tissue, lateral ventricles, cortex, cerebellum and extra-cerebral CSF and 2D measurements of brain biparietal diameter and fronto-occipital length, skull biparietal diameter and occipitofrontal diameter, head circumference, transverse cerebellar diameter, extra-cerebral CSF, ventricular atrial diameter, and vermis height, width, and area. Centiles were constructed for each measurement. All participants were invited for developmental follow-up. All 2D and 3D measurements, except for atrial diameter, showed a significant positive correlation with gestational age. There was a sex effect on left and total lateral ventricular volumes and the degree of ventricular asymmetry. The 5th, 50th, and 95th centiles and a centile calculator were produced. Developmental follow-up was available for 73.1% of cases [mean chronological age 27.4 (±10.2) months]. We present normative reference charts for fetal brain MRI biometry at 21-38 gestational weeks. Developing growth trajectories will aid in the better understanding of normal fetal brain growth and subsequently of deviations from typical development in high-risk pregnancies or following premature delivery.

  3. Relationship between ultrasound estimated fetal gestational age and cerebellar appearance in healthy pregnant Nigerian women.

    PubMed

    Adeyekun, Ademola A; Orji, Michael O

    2015-01-01

    Fetal biometry by ultrasound provides reliable and important information about fetal growth and wellbeing. Evaluation of the fetal posterior fossa is useful in the assessment of neural tube-defects. Studies on normal ultrasound fetal cerebellar appearance and diameter across gestational age (GA) are scanty in the Nigerian medical literature. This study was carried out to study normal fetal cerebellar appearance and diameter at various GAs among healthy pregnant Nigerian Africans. This was a prospective study of 450 healthy singleton pregnant women between 13 and 42 weeks gestation. A curvilinear probe with a 3.5 MHz transducer of a SonoAce X6 (Medison Inc., Korea 2010) scanner was used to assess fetal transcerebellar diameter (TCD) and appearance. GA was also determined using fetal biometric parameters such as the biparietal diameter, femur length, and abdominal circumference. Fetal cerebellar appearance was correlated against GA. The cerebellar appearance was graded into: Grade I: 164 fetuses (36.4%), Grade II; 102 fetuses (22.7%) and Grade III: 184 fetuses (40.9%). Mean GA and TCD was 21 weeks and 21.2 mm for Grade I; 28 weeks and 32.6 mm for Grade II; and 35 weeks and 47.1 mm for Grade III. There was significance difference among the cerebellar grades at the GA groups and transverse cerebellar diameter (P < 0.000). There is a gradual and steady change in ultrasonographic appearance of the fetal cerebellar and diameter appearance with advancing gestation. The changes ranged from anechoic, "pair of eye glass" appearance at second trimester to relatively echogenic, "dumb-bell" appearance at early third trimester, and solid, "fan-shape" in late third trimester.

  4. Identification of risk factors for mucosal injury during laparoscopic Heller myotomy for achalasia.

    PubMed

    Tsuboi, Kazuto; Omura, Nobuo; Yano, Fumiaki; Hoshino, Masato; Yamamoto, Se-Ryung; Akimoto, Shusuke; Masuda, Takahiro; Kashiwagi, Hideyuki; Yanaga, Katsuhiko

    2016-02-01

    Mucosal injury during myotomy is the most frequent complication seen with the Heller-Dor procedure for achalasia. The present study aimed to examine risk factors for such mucosal injury during this procedure. This was a retrospective analysis of patients who underwent the laparoscopic Heller-Dor procedure for achalasia at a single facility. Variables for evaluation included patient characteristics, preoperative pathophysiological findings, and surgeon's operative experience. Logistic regression was used to identify risk factors. We also examined surgical outcomes and the degree of patient satisfaction in relation to intraoperative mucosal injury. Four hundred thirty-five patients satisfied study criteria. Intraoperative mucosal injury occurred in 67 patients (15.4%). In univariate analysis, mucosal injury was significantly associated with the patient age ≥60 years, disease history ≥10 years, prior history of cardiac diseases, preoperative esophageal transverse diameter ≥80 mm, and surgeon's operative experience with fewer than five cases. In multivariate analysis involving these factors, the following variables were identified as risk factors: age ≥60 years, esophageal transverse diameter ≥80 mm, and surgeon's operative experience with fewer than five cases. The mucosal injury group had significant extension of the operative time and increased blood loss. However, there were no significant differences between the two groups in the incidence of reflux esophagitis or the degree of symptom alleviation postoperatively. The fragile esophagus caused by advanced patient age and/or dilatation were risk factor for mucosal injury during laparoscopic Heller-Dor procedure. And novice surgeon was also identified as an isolated risk factor for mucosal injury.

  5. Coupled microstrip line transverse electromagnetic resonator model for high-field magnetic resonance imaging.

    PubMed

    Bogdanov, G; Ludwig, R

    2002-03-01

    The performance modeling of RF resonators at high magnetic fields of 4.7 T and more requires a physical approach that goes beyond conventional lumped circuit concepts. The treatment of voltages and currents as variables in time and space leads to a coupled transmission line model, whereby the electric and magnetic fields are assumed static in planes orthogonal to the length of the resonator, but wave-like along its longitudinal axis. In this work a multiconductor transmission line (MTL) model is developed and successfully applied to analyze a 12-element unloaded and loaded microstrip line transverse electromagnetic (TEM) resonator coil for animal studies. The loading involves a homogeneous cylindrical dielectric insert of variable radius and length. This model formulation is capable of estimating the resonance spectrum, field distributions, and certain types of losses in the coil, while requiring only modest computational resources. The boundary element method is adopted to compute all relevant transmission line parameters needed to set up the transmission line matrices. Both the theoretical basis and its engineering implementation are discussed and the resulting model predictions are placed in context with measurements. A comparison between a conventional lumped circuit model and this distributed formulation is conducted, showing significant departures in the resonance response at higher frequencies. This MTL model is applied to simulate two small-bore animal systems: one of 7.5-cm inner diameter, tuned to 200 MHz (4.7 T for proton imaging), and one of 13.36-cm inner diameter, tuned to both 200 and 300 MHz (7 T). Copyright 2002 Wiley-Liss, Inc.

  6. Driven motion and instability of an atmospheric pressure arc

    NASA Astrophysics Data System (ADS)

    Karasik, Max

    Atmospheric pressure arcs are used extensively in applications such as welding and metallurgy. However, comparatively little is known of the physics of such arcs in external magnetic fields and the mechanisms of the instabilities present. In order to address questions of equilibrium and stability of such arcs, an experimental are furnace is constructed and operated in air with graphite cathode and steel anode at currents 100--250 A. The arc is diagnosed with a gated intensified camera and a collimated photodiode array, as well as fast voltage and current probes. Experiments are carried out on the response of the are to applied transverse DC and AC (up to ≈1 kHz) magnetic fields. The arc is found to deflect parabolically for DC field and assumes a growing sinusoidal structure for AC field. A simple analytic two-parameter fluid model of the are dynamics is derived, in which the inertia of the magnetically pumped cathode jet balances the applied J⃗xB⃗ force. Time variation of the applied field allows evaluation of the parameters individually. A fit of the model to the experimental data gives a value for the average jet speed an order of magnitude below Maecker's estimate of the maximum jet speed. A spontaneous instability of the same arc is investigated experimentally and modeled analytically. The presence of the instability is found to depend critically on cathode dimensions. For cylindrical cathodes, instability occurs only for a narrow range of cathode diameters. Cathode spot motion is proposed as the mechanism of the instability. A simple fluid model combining the effect of the cathode spot motion and the inertia of the cathode jet successfully describes the arc shape during low amplitude instability. The amplitude of cathode spot motion required by the model is in agreement with measurements. The average jet velocity required is approximately equal to that inferred from the transverse magnetic field experiments. Reasons for spot motion and for cathode geometry dependence are discussed. An exploratory study of the instability of the arc in applied axial magnetic field is also described. Applicability of the results of the thesis to an industrial steelmaking furnace is considered.

  7. Theoretical analysis for condensation heat transfer of binary refrigerant mixtures with annular flow in horizontal mini-tubes

    NASA Astrophysics Data System (ADS)

    Zhang, Hui-Yong; Li, Jun-Ming; Sun, Ji-Liang; Wang, Bu-Xuan

    2016-01-01

    A theoretical model is developed for condensation heat transfer of binary refrigerant mixtures in mini-tubes with diameter about 1.0 mm. Condensation heat transfer of R410A and R32/R134a mixtures at different mass fluxes and saturated temperatures are analyzed, assuming that the phase flow pattern is annular flow. The results indicate that there exists a maximum interface temperature at the beginning of condensation process for azeotropic and zeotropic mixtures and the corresponding vapor quality to the maximum value increases with mass flux. The effects of mass flux, heat flux, surface tension and tube diameter are analyzed. As expected, the condensation heat transfer coefficients increase with mass flux and vapor quality, and increase faster in high vapor quality region. It is found that the effects of heat flux and surface tension are not so obvious as that of tube diameter. The characteristics of condensation heat transfer of zeotropic mixtures are consistent to those of azeotropic refrigerant mixtures. The condensation heat transfer coefficients increase with the concentration of the less volatile component in binary mixtures.

  8. Comparative stereology of the mouse and finch left ventricle.

    PubMed

    Bossen, E H; Sommer, J R; Waugh, R A

    1978-01-01

    The volume fractions and surface per unit cell volume of some subcellular components of the left ventricles of the finch and mouse were quantitated by stereologic techniques. These species were chosen for study because they have similar heart rates but differ morphologically in some respects: fiber diameter is larger in the mouse; the mouse has transverse tubules while the finch does not; and the finch has a form of junctional sarcoplasmic reticulum (JSR), extended JSR (EJSR), located in the cell interior with no direct plasmalemmal contact, while the mouse interior JSR (IJSR) abuts on transverse tubules. Our data show that the volume fraction (Vv) and surface area per unit cell volume (Sv) of total SR, and free SR (FSR) are similar. The volume fractions of mitochondria, myofibrils, and total junctional SR were also similar. The Sv of the cell surface of the finch was similar to the Sv of the cell surface of the mouse (Sv-plasmalemma plus Sv of the transverse tubules). The principal difference was in the distribution of JSR; the mouse peripheral JSR (PJSR) represents only 9% of the total JSR, while the finch PJSR accounts for 24% of the bird's JSR. The similar volume fractions of total junctional SR (PJSR + EJSR in the finch; PJSR + IJSR in the mouse) suggest that the EJSR is not an embryologic remnant, and raises the possibility that some function of JSR is independent of plasmalemmal contact.

  9. Electrical transport in transverse direction through silicon carbon alloy multilayers containing regular size silicon quantum dots

    NASA Astrophysics Data System (ADS)

    Mandal, Aparajita; Kole, Arindam; Dasgupta, Arup; Chaudhuri, Partha

    2016-11-01

    Electrical transport in the transverse direction has been studied through a series of hydrogenated silicon carbon alloy multilayers (SiC-MLs) deposited by plasma enhanced chemical vapor deposition method. Each SiC-ML consists of 30 cycles of the alternating layers of a nearly amorphous silicon carbide (a-SiC:H) and a microcrystalline silicon carbide (μc-SiC:H) that contains high density of silicon quantum dots (Si-QDs). A detailed investigation by cross sectional TEM reveals preferential growth of densely packed Si-QDs of regular sizes ∼4.8 nm in diameter in a vertically aligned columnar structure within the SiC-ML. More than six orders of magnitude increase in transverse current through the SiC-ML structure were observed for decrease in the a-SiC:H layer thickness from 13 nm to 2 nm. The electrical transport mechanism was established to be a combination of grain boundary or band tail hopping and Frenkel-Poole (F-P) type conduction depending on the temperature and externally applied voltage ranges. Evaluation of trap concentration within the multilayer structures from the fitted room temperature current voltage characteristics by F-P function shows reduction up-to two orders of magnitude indicating an improvement in the short range order in the a-SiC:H matrix for decrease in the thickness of a-SiC:H layer.

  10. Transverse changes determined by rapid and slow maxillary expansion--a low-dose CT-based randomized controlled trial.

    PubMed

    Martina, R; Cioffi, I; Farella, M; Leone, P; Manzo, P; Matarese, G; Portelli, M; Nucera, R; Cordasco, G

    2012-08-01

    To compare transverse skeletal changes produced by rapid (RME) and slow (SME) maxillary expansion using low-dose computed tomography. The null hypothesis was that SME and RME are equally effective in producing skeletal maxillary expansion in patients with posterior crossbite. This study was carried out at the Department of Oral Sciences, University of Naples Federico II, Italy. Twelve patients (seven males, five females, mean age ± SD: 10.3 ± 2.5 years) were allocated to the SME group and 14 patients (six males, eight females, mean age ± SD: 9.7 ± 1.5 years) to the RME group. All patients received a two-band palatal expander and were randomly allocated to either RME or SME. Low-dose computed tomography was used to identify skeletal and dental landmarks and to measure transverse maxillary changes with treatment. A significant increase in skeletal transverse diameters was found in both SME and RME groups (anterior expansion = 2.2 ± 1.4 mm, posterior expansion = 2.2 ± 0.9 mm, pterygoid expansion = 0.9 ± 0.8 mm). No significant differences were found between groups at anterior (SME = 1.9 ± 1.3 mm; RME = 2.5 ± 1.5 mm) or posterior (SME = 1.9 ± 1.0 mm; RME = 2.4 ± 0.9 mm) locations, while a statistically significant difference was measured at the pterygoid processes (SME = 0.6 ± 0.6 mm; RME = 1.2 ± 0.9 mm, p = 0.04), which was not clinically relevant. Rapid maxillary expansion is not more effective than SME in expanding the maxilla in patients with posterior crossbite. © 2012 John Wiley & Sons A/S.

  11. Direct tests of a pixelated microchannel plate as the active element of a shower maximum detector

    DOE PAGES

    Apresyan, A.; Los, S.; Pena, C.; ...

    2016-05-07

    One possibility to make a fast and radiation resistant shower maximum detector is to use a secondary emitter as an active element. We report our studies of microchannel plate photomultipliers (MCPs) as the active element of a shower-maximum detector. We present test beam results obtained using Photonis XP85011 to detect secondary particles of an electromagnetic shower. We focus on the use of the multiple pixels on the Photonis MCP in order to find a transverse two-dimensional shower distribution. A spatial resolution of 0.8 mm was obtained with an 8 GeV electron beam. As a result, a method for measuring themore » arrival time resolution for electromagnetic showers is presented, and we show that time resolution better than 40 ps can be achieved.« less

  12. Direct tests of a pixelated microchannel plate as the active element of a shower maximum detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Apresyan, A.; Los, S.; Pena, C.

    One possibility to make a fast and radiation resistant shower maximum detector is to use a secondary emitter as an active element. We report our studies of microchannel plate photomultipliers (MCPs) as the active element of a shower-maximum detector. We present test beam results obtained using Photonis XP85011 to detect secondary particles of an electromagnetic shower. We focus on the use of the multiple pixels on the Photonis MCP in order to find a transverse two-dimensional shower distribution. A spatial resolution of 0.8 mm was obtained with an 8 GeV electron beam. As a result, a method for measuring themore » arrival time resolution for electromagnetic showers is presented, and we show that time resolution better than 40 ps can be achieved.« less

  13. Craters formed in mineral dust by hypervelocity microparticles.

    NASA Technical Reports Server (NTRS)

    Vedder, J. F.

    1972-01-01

    As a simulation of erosion processes on the lunar surface, impact craters were formed in dust targets by 2- to 5-micron-diameter polystyrene spheres with velocities between 2.5 and 12 km/sec. For weakly cohesive, thick targets of basalt dust with a maximum grain size comparable to the projectile diameter, the craters had an average projectile-to-diameter diameter ratio of 25, and the displaced mass was 3 orders of magnitude greater than the projectile mass. In a simulation of the effect of a dust covering on lunar rocks, a layer of cohesive, fine-grained basalt dust with a thickness nearly twice the projectile diameter protected a glass substrate from damage, but an area about 50 times the cross-sectional area of the projectile was cleared of all but a few grains. Impact damage was produced in glass under a thinner dust layer.

  14. Is There a Maximum Size of Water Drops in Nature?

    ERIC Educational Resources Information Center

    Vollmer, Michael; Mollmann, Klaus-Peter

    2013-01-01

    In nature, water drops can have a large variety of sizes and shapes. Small droplets with diameters of the order of 5 to 10 µm are present in fog and clouds. This is not sufficiently large for gravity to dominate their behavior. In contrast, raindrops typically have sizes of the order of 1 mm, with observed maximum sizes in nature of around 5 mm in…

  15. Relative maxima of diameter and basal area

    Treesearch

    Thomas B. Lynch; Difei Zhang

    2012-01-01

    It has often been observed that maximum dbh growth occurs at an earlier age than maximum individual tree basal area growth. This can be deduced from the geometry of the tree stem, by observing that a dbh increment at a given radius will be associated with a larger basal area increment than an equal dbh increment occurring at a shorter radius from the stem center. Thus...

  16. PROFIT-PC: a program for estimating maximum net revenue from multiproduct harvests in Appalachian hardwoods

    Treesearch

    Chris B. LeDoux; John E. Baumgras; R. Bryan Selbe

    1989-01-01

    PROFIT-PC is a menu driven, interactive PC (personal computer) program that estimates optimum product mix and maximum net harvesting revenue based on projected product yields and stump-to-mill timber harvesting costs. Required inputs include the number of trees/acre by species and 2 inches diameter at breast-height class, delivered product prices by species and product...

  17. Correlation Between Transperineal 3-Dimensional Ultrasound Measurements of Levator Hiatus and Female Sexual Function.

    PubMed

    Aydin, Serdar; Bakar, Rabia Zehra; Arioğlu Aydin, Çağri; Ateş, Seda

    The aim of this study is to investigate the association of sexual functions with levator hiatus biometry measurements and levator ani muscle defect. In 62 heterosexual, sexually active premenopausal women without pelvic floor disorders or urinary incontinence, 3-dimensional transperineal ultrasound imaging was used. Two 3-dimensional volumes were recorded, one at rest and one on Valsalva maneuver. Levator biometry measurements and levator defect were evaluated in an axial plane. Sexual function was assessed by a validated questionnaire, Female Sexual Function Index (FSFI). The primary outcome measure was correlation of sexual functions with the levator hiatus area, transverse and anteroposterior diameters, levator ani muscle thickness, vaginal length, and changes in measurements with Valsalva and levator defect. Forty-two women (67.7%) had low total FSFI scores (<26.55). Levator defect rates were similar in female sexual dysfunction (7/42, 16.7%) and women without female sexual dysfunction (5/20, 25%). The FSFI was negatively and weakly correlated with Δhiatal anteroposterior diameter (r = -0.33, P < 0.009) in the study population. There was a weak and inverse correlation between Δhiatal anteroposterior diameter and arousal (r = -0.35, P < 0.002), desire (r = -0.38, P < 0.001), and orgasm (r = -0.33, P < 0.007). Pain and lubrication did not correlate with any measurement. Hiatal area and diameters at rest are not related to sexual functions. Changes in anteroposterior diameter of the levator hiatus during Valsalva, which may be a sign of pelvic floor laxity or levator muscle weakness, are weakly associated with sexual functions, particularly desire, arousal, and orgasm domains.

  18. The effect of different temperature profiles upon the length and crystallinity of vertically-aligned multi-walled carbon nanotubes.

    PubMed

    Yun, Jongju; Lee, Cheesung; Zheng, Qing; Baik, Seunghyun

    2012-08-01

    We synthesized vertically-aligned multi-walled carbon nanotubes with an inner diameter of 1.6-7.5 nm and stack height of 80-28600 microm by chemical vapor deposition. The effects of synthesis conditions such as substrate position in the tube furnace, maximum temperature, temperature increasing rate and synthesis duration on the structure of nanotubes were investigated. It was found that slightly faster temperature increase rate resulted in significantly longer length, larger diameter and more defects of nanotubes. Structural parameters such as inner, outer diameters, wall thickness and defects were investigated using transmission electron microscopy and Raman spectroscopy.

  19. Burnout current density of bismuth nanowires

    NASA Astrophysics Data System (ADS)

    Cornelius, T. W.; Picht, O.; Müller, S.; Neumann, R.; Völklein, F.; Karim, S.; Duan, J. L.

    2008-05-01

    Single bismuth nanowires with diameters ranging from 100nmto1μm were electrochemically deposited in ion track-etched single-pore polycarbonate membranes. The maximum current density the wires are able to carry was investigated by ramping up the current until failure occurred. It increases by three to four orders of magnitude for nanowires embedded in the template compared to bulk bismuth and rises with diminishing diameter. Simulations show that the wires are heated up electrically to the melting temperature. Since the surface-to-volume ratio rises with diminishing diameter, thinner wires dissipate the heat more efficiently to the surrounding polymer matrix and, thus, can tolerate larger current densities.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Bochong; Kubota, Hitoshi, E-mail: hit-kubota@aist.go.jp; Yakushiji, Kay

    The dependence on diameter of the emission power in MgO-based nano-pillar spin torque oscillators (STOs) was systematically investigated. A maximum emission power of over 2.5 μW was obtained around 300 nm in diameter, which is the largest reported to date among the out-of-plane precession STOs. By analyzing physical quantities, precession cone angle of the free-layer magnetization was evaluated. In the diameter range below 300 nm, the increase in power was mainly due to the increase of the injected current. The power decrease above 300 nm is possibly attributed to the decrease in the averaged precession cone angle, suggesting spatial phase difference of magnetization precession.more » This study provides the method for estimating the optimum STO diameter, which is of great importance in practical use.« less

  1. Solid-state Yb : YAG amplifier pumped by a single-mode laser at 920 nm

    NASA Astrophysics Data System (ADS)

    Obronov, I. V.; Demkin, A. S.; Myasnikov, D. V.

    2018-03-01

    An optical amplifier scheme for ultrashort 1030-nm pulses is proposed based on an Yb : YAG crystal with axial pumping by a transverse single-mode laser at a wavelength of 920 nm. A small-signal gain up to 40 dB per pass with a high output beam quality is demonstrated. The maximum average power is 14 W with a slope efficiency exceeding 50%.

  2. Improved optics for an ultracentrifuge

    NASA Technical Reports Server (NTRS)

    Miller, C. G.; Stephens, J. B.

    1980-01-01

    Ultracentrifuge is important tool in study of polymers, biomolecules, and cell structures. In typical ultracentrifuge rotor supports pair of optically matched vials; one contains sample mixed in solvent, and other is reference that contains only solvent. Doubleslit optical system, transverse to rotor, creates interference pattern on photographic plate each time vials pass through optics. Medium in sample vial displaces interference maximums such that shift gives measurement of density distribution along length of sample.

  3. Turbulent Mixing in Exponential Transverse Jets

    DTIC Science & Technology

    1990-09-30

    parameter. The flame length of the jets is a direct measurement of the molecular scale mixing rate. ACCOMPLISHMENTS From observations of the trajectory...and cross-sectional size of the vortices, as well as the flame length , our measurements reveal the following: i) Under acceleration, the roll up and... flame lengths are a weak maximum when the acceleration parameter (x is about unity. For large cc, flame lengths slowly decline with increasing a, in

  4. Experimental investigation of damage behavior of RC frame members including non-seismically designed columns

    NASA Astrophysics Data System (ADS)

    Chen, Linzhi; Lu, Xilin; Jiang, Huanjun; Zheng, Jianbo

    2009-06-01

    Reinforced concrete (RC) frame structures are one of the mostly common used structural systems, and their seismic performance is largely determined by the performance of columns and beams. This paper describes horizontal cyclic loading tests of ten column and three beam specimens, some of which were designed according to the current seismic design code and others were designed according to the early non-seismic Chinese design code, aiming at reporting the behavior of the damaged or collapsed RC frame strctures observed during the Wenchuan earthquake. The effects of axial load ratio, shear span ratio, and transverse and longitudinal reinforcement ratio on hysteresis behavior, ductility and damage progress were incorporated in the experimental study. Test results indicate that the non-seismically designed columns show premature shear failure, and yield larger maximum residual crack widths and more concrete spalling than the seismically designed columns. In addition, longitudinal steel reinforcement rebars were severely buckled. The axial load ratio and shear span ratio proved to be the most important factors affecting the ductility, crack opening width and closing ability, while the longitudinal reinforcement ratio had only a minor effect on column ductility, but exhibited more influence on beam ductility. Finally, the transverse reinforcement ratio did not influence the maximum residual crack width and closing ability of the seismically designed columns.

  5. Analysis of bonded joints. [shear stress and stress-strain diagrams

    NASA Technical Reports Server (NTRS)

    Srinivas, S.

    1975-01-01

    A refined elastic analysis of bonded joints which accounts for transverse shear deformation and transverse normal stress was developed to obtain the stresses and displacements in the adherends and in the bond. The displacements were expanded in terms of polynomials in the thicknesswise coordinate; the coefficients of these polynomials were functions of the axial coordinate. The stress distribution was obtained in terms of these coefficients by using strain-displacement and stress-strain relations. The governing differential equations were obtained by integrating the equations of equilibrium, and were solved. The boundary conditions (interface or support) were satisfied to complete the analysis. Single-lap, flush, and double-lap joints were analyzed, along with the effects of adhesive properties, plate thicknesses, material properties, and plate taper on maximum peel and shear stresses in the bond. The results obtained by using the thin-beam analysis available in the literature were compared with the results obtained by using the refined analysis. In general, thin-beam analysis yielded reasonably accurate results, but in certain cases the errors were high. Numerical investigations showed that the maximum peel and shear stresses in the bond can be reduced by (1) using a combination of flexible and stiff bonds, (2) using stiffer lap plates, and (3) tapering the plates.

  6. Water and lipid diffusion MRI using chemical shift displacement-based separation of lipid tissue (SPLIT).

    PubMed

    Ohno, Naoki; Kan, Hirohito; Miyati, Tosiaki; Aoki, Toshitaka; Ishida, Shota; Gabata, Toshifumi

    2017-06-01

    To obtain water and lipid diffusion-weighted images (DWIs) simultaneously, we devised a novel method utilizing chemical shift displacement-based separation of lipid tissue (SPLIT) imaging. Single-shot diffusion echo-planar imaging without fat suppression was used and the imaging parameters were optimized to separate water and lipid DWIs by chemical shift displacement of the lipid signals along the phase-encoding direction. Using the optimized conditions, transverse DWIs at the maximum diameter of the right calf were scanned with multiple b-values in five healthy subjects. Then, apparent diffusion coefficients (ADCs) were calculated in the tibialis anterior muscle (TA), tibialis bone marrow (TB), and subcutaneous fat (SF), as well as restricted and perfusion-related diffusion coefficients (D and D*, respectively) and the fraction of the perfusion-related diffusion component (F) for TA. Water and lipid DWIs were separated adequately. The mean ADCs of the TA, TB, and SF were 1.56±0.03mm 2 /s, 0.01±0.01mm 2 /s, and 0.06±0.02mm 2 /s, respectively. The mean D*, D, and F of the TA were 13.7±4.3mm 2 /s, 1.48±0.05mm 2 /s, and 4.3±1.6%, respectively. SPLIT imaging makes it possible to simply and simultaneously obtain water and lipid DWIs without special pulse sequence and increases the amount of diffusion information of water and lipid tissue. Copyright © 2017. Published by Elsevier Inc.

  7. In vivo imaging of retinal pigment epithelium cells in age related macular degeneration

    PubMed Central

    Rossi, Ethan A.; Rangel-Fonseca, Piero; Parkins, Keith; Fischer, William; Latchney, Lisa R.; Folwell, Margaret A.; Williams, David R.; Dubra, Alfredo; Chung, Mina M.

    2013-01-01

    Morgan and colleagues demonstrated that the RPE cell mosaic can be resolved in the living human eye non-invasively by imaging the short-wavelength autofluorescence using an adaptive optics (AO) ophthalmoscope. This method, based on the assumption that all subjects have the same longitudinal chromatic aberration (LCA) correction, has proved difficult to use in diseased eyes, and in particular those affected by age-related macular degeneration (AMD). In this work, we improve Morgan’s method by accounting for chromatic aberration variations by optimizing the confocal aperture axial and transverse placement through an automated iterative maximization of image intensity. The increase in image intensity after algorithmic aperture placement varied depending upon patient and aperture position prior to optimization but increases as large as a factor of 10 were observed. When using a confocal aperture of 3.4 Airy disks in diameter, images were obtained using retinal radiant exposures of less than 2.44 J/cm2, which is ~22 times below the current ANSI maximum permissible exposure. RPE cell morphologies that were strikingly similar to those seen in postmortem histological studies were observed in AMD eyes, even in areas where the pattern of fluorescence appeared normal in commercial fundus autofluorescence (FAF) images. This new method can be used to study RPE morphology in AMD and other diseases, providing a powerful tool for understanding disease pathogenesis and progression, and offering a new means to assess the efficacy of treatments designed to restore RPE health. PMID:24298413

  8. Peripheral Nerve Stimulation Characteristics of an Asymmetric Head-Only Gradient Coil Compatible with a High-Channel-Count Receiver Array

    PubMed Central

    Lee, Seung-Kyun; Mathieu, Jean-Baptiste; Graziani, Dominic; Piel, Joseph; Budesheim, Eric; Fiveland, Eric; Hardy, Christopher J.; Tan, Ek Tsoon; Amm, Bruce; Foo, Thomas K.-F; Bernstein, Matt A.; Huston, John; Shu, Yunhong; Schenck, John F.

    2015-01-01

    Purpose To characterize peripheral nerve stimulation (PNS) of an asymmetric head-only gradient coil that is compatible with a commercial high-channel-count receive-only array. Methods Two prototypes of an asymmetric head-only gradient coil set, with 42-cm inner diameter, were constructed for brain imaging at 3T with maximum performance specifications of up to 85 mT/m and 708 T/m/s. 24 volunteer tests were performed to measure PNS thresholds with the transverse (X, left/right; Y, anterior/posterior) gradient coils of both prototypes. 14 volunteers were also tested for the Z-gradient PNS in the second prototype, and were additionally scanned with high-slew-rate EPI immediately after the PNS tests. Results For both prototypes, the Y-gradient PNS threshold was markedly higher than the X-gradient. The Z-gradient threshold was intermediate between those for the X- and Y-coils. Out of the 24 volunteer subjects, only two experienced Y-gradient PNS at 80 mT/m, 500 T/m/s. All volunteers underwent the EPI scan without PNS when the readout direction was set to A/P. Conclusion Measured PNS characteristics of asymmetric head-only gradient coil prototypes indicate that such coils, especially in the A/P direction, can be used for fast EPI readout in high-performance neuroimaging scans with substantially reduced PNS concerns compared to conventional whole-body gradient coils. PMID:26628078

  9. Seismic Design of a Single Bored Tunnel: Longitudinal Deformations and Seismic Joints

    NASA Astrophysics Data System (ADS)

    Oh, J.; Moon, T.

    2018-03-01

    The large diameter bored tunnel passing through rock and alluvial deposits subjected to seismic loading is analyzed for estimating longitudinal deformations and member forces on the segmental tunnel liners. The project site has challenges including high hydrostatic pressure, variable ground profile and high seismic loading. To ensure the safety of segmental tunnel liner from the seismic demands, the performance-based two-level design earthquake approach, Functional Evaluation Earthquake and Safety Evaluation Earthquake, has been adopted. The longitudinal tunnel and ground response seismic analyses are performed using a three-dimensional quasi-static linear elastic and nonlinear elastic discrete beam-spring elements to represent segmental liner and ground spring, respectively. Three components (longitudinal, transverse and vertical) of free-field ground displacement-time histories evaluated from site response analyses considering wave passage effects have been applied at the end support of the strain-compatible ground springs. The result of the longitudinal seismic analyses suggests that seismic joint for the mitigation measure requiring the design deflection capacity of 5-7.5 cm is to be furnished at the transition zone between hard and soft ground condition where the maximum member forces on the segmental liner (i.e., axial, shear forces and bending moments) are induced. The paper illustrates how detailed numerical analyses can be practically applied to evaluate the axial and curvature deformations along the tunnel alignment under difficult ground conditions and to provide the seismic joints at proper locations to effectively reduce the seismic demands below the allowable levels.

  10. Lesion detection performance of cone beam CT images with anatomical background noise: single-slice vs. multi-slice human and model observer study

    NASA Astrophysics Data System (ADS)

    Han, Minah; Jang, Hanjoo; Baek, Jongduk

    2018-03-01

    We investigate lesion detectability and its trends for different noise structures in single-slice and multislice CBCT images with anatomical background noise. Anatomical background noise is modeled using a power law spectrum of breast anatomy. Spherical signal with a 2 mm diameter is used for modeling a lesion. CT projection data are acquired by the forward projection and reconstructed by the Feldkamp-Davis-Kress algorithm. To generate different noise structures, two types of reconstruction filters (Hanning and Ram-Lak weighted ramp filters) are used in the reconstruction, and the transverse and longitudinal planes of reconstructed volume are used for detectability evaluation. To evaluate single-slice images, the central slice, which contains the maximum signal energy, is used. To evaluate multislice images, central nine slices are used. Detectability is evaluated using human and model observer studies. For model observer, channelized Hotelling observer (CHO) with dense difference-of-Gaussian (D-DOG) channels are used. For all noise structures, detectability by a human observer is higher for multislice images than single-slice images, and the degree of detectability increase in multislice images depends on the noise structure. Variation in detectability for different noise structures is reduced in multislice images, but detectability trends are not much different between single-slice and multislice images. The CHO with D-DOG channels predicts detectability by a human observer well for both single-slice and multislice images.

  11. Single-mode operation of mushroom structure surface emitting lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Y.J.; Dziura, T.G.; Wang, S.C.

    1991-01-01

    Mushroom structure vertical cavity surface emitting lasers with a 0.6 {mu}m GaAs active layer sandwiched by two Al{sub 0.6{sup {minus}}}Ga{sub 0.4}As-Al{sub 0.08}Ga{sub 0.92}As multilayers as top and bottom mirrors exhibit 15 mA pulsed threshold current at 880 nm. Single longitudinal and single transverse mode operation was achieved on lasers with a 5 {mu}m diameter active region at current levels near 2 {times} I{sub th}. The light output above threshold current was linearly polarized with a polarization ratio of 25:1.

  12. Photoelectron yields of scintillation counters with embedded wavelength-shifting fibers read out with silicon photomultipliers

    DOE PAGES

    Artikov, Akram; Baranov, Vladimir; Blazey, Gerald C.; ...

    2018-02-14

    Photoelectron yields of extruded scintillation counters with titanium dioxide coating and embedded wavelength shifting fibers read out by silicon photomultipliers have been measured at the Fermilab Test Beam Facility using 120,GeV protons. The yields were measured as a function of transverse, longitudinal, and angular positions for a variety of scintillator compositions and reflective coating mixtures, fiber diameters, and photosensor sizes. Timing performance was also studied. These studies were carried out by the Cosmic Ray Veto Group of the Mu2e collaboration as part of their R\\&D program.

  13. Photoelectron yields of scintillation counters with embedded wavelength-shifting fibers read out with silicon photomultipliers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Artikov, Akram; Baranov, Vladimir; Blazey, Gerald C.

    Photoelectron yields of extruded scintillation counters with titanium dioxide coating and embedded wavelength shifting fibers read out by silicon photomultipliers have been measured at the Fermilab Test Beam Facility using 120,GeV protons. The yields were measured as a function of transverse, longitudinal, and angular positions for a variety of scintillator compositions and reflective coating mixtures, fiber diameters, and photosensor sizes. Timing performance was also studied. These studies were carried out by the Cosmic Ray Veto Group of the Mu2e collaboration as part of their R\\&D program.

  14. Laser anemometer using a Fabry-Perot interferometer for measuring mean velocity and turbulence intensity along the optical axis in turbomachinery

    NASA Technical Reports Server (NTRS)

    Seasholtz, R. G.; Goldman, L. J.

    1982-01-01

    A technique for measuring a small optical axis velocity component in a flow with a large transverse velocity component is presented. Experimental results are given for a subsonic free jet operating in a laboratory environment, and for a 0.508 meter diameter turbine stator cascade. Satisfactory operation of the instrument was demonstrated in the stator cascade facility with an ambient acoustic noise level during operation of about 105 dB. In addition, the turbulence intensity measured with the interferometer was consistent with previous measurements taken with a fringe type laser anemometer.

  15. Photoelectron yields of scintillation counters with embedded wavelength-shifting fibers read out with silicon photomultipliers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Artikov, Akram; Baranov, Vladimir; Blazey, Gerald C.

    2018-05-01

    Photoelectron yields of extruded scintillation counters with titanium dioxide coating and embedded wavelength shifting fibers read out by silicon photomultipliers have been measured at the Fermilab Test Beam Facility using 120\\,GeV protons. The yields were measured as a function of transverse, longitudinal, and angular positions for a variety of scintillator compositions and reflective coating mixtures, fiber diameters, and photosensor sizes. Timing performance was also studied. These studies were carried out by the Cosmic Ray Veto Group of the Mu2e collaboration as part of their R\\&D program.

  16. Characterization, parameter estimation, and aircraft response statistics of atmospheric turbulence

    NASA Technical Reports Server (NTRS)

    Mark, W. D.

    1981-01-01

    A nonGaussian three component model of atmospheric turbulence is postulated that accounts for readily observable features of turbulence velocity records, their autocorrelation functions, and their spectra. Methods for computing probability density functions and mean exceedance rates of a generic aircraft response variable are developed using nonGaussian turbulence characterizations readily extracted from velocity recordings. A maximum likelihood method is developed for optimal estimation of the integral scale and intensity of records possessing von Karman transverse of longitudinal spectra. Formulas for the variances of such parameter estimates are developed. The maximum likelihood and least-square approaches are combined to yield a method for estimating the autocorrelation function parameters of a two component model for turbulence.

  17. A computational study of crimping and expansion of bioresorbable polymeric stents

    NASA Astrophysics Data System (ADS)

    Qiu, T. Y.; Song, M.; Zhao, L. G.

    2018-05-01

    This paper studied the mechanical performance of four bioresorbable PLLA stents, i.e., Absorb, Elixir, Igaki-Tamai and RevaMedical, during crimping and expansion using the finite element method. Abaqus CAE was used to create the geometrical models for the four stents. A tri-folded balloon was created using NX software. For the stents, elastic-plastic behaviour was used, with hardening implemented by considering the increase of yield stress with the plastic strain. The tri-folded balloon was treated as linear elastic. To simulate the crimping of stents, a set of 12 rigid plates were generated around the stents with a radially enforced displacement. During crimping, the stents were compressed from a diameter of 3 mm to 1.2 mm, with the maximum stress developed at both inner and outer sides of the U-bends. During expansion, the stent inner diameter increased to 3 mm at the peak pressure and then recoiled to different final diameters after balloon deflation due to different stent designs. The maximum stress was found again at the U-bends of stents. Diameter change, recoiling effect and radial strength/stiffness were also compared for the four stents to assess the effect of design variation on stent performance. The effect of loading rate on stent deformation was also simulated by considering the time-dependent plastic behaviour of polymeric material.

  18. Corneal Epithelium Thickness Profile in 614 Normal Chinese Children Aged 7-15 Years Old.

    PubMed

    Ma, Yingyan; He, Xiangui; Zhu, Xiaofeng; Lu, Lina; Zhu, Jianfeng; Zou, Haidong

    2016-03-23

    The purpose of the study is to describe the values and distribution of corneal epithelium thickness (CET) in normal Chinese school-aged children, and to explore associated factors with CET. CET maps were measured by Fourier-domain optical coherence tomography (FD-OCT) in normal Chinese children aged 7 to 15 years old from two randomly selected schools in Shanghai, China. Children with normal intraocular pressure were further examined for cycloplegic autorefraction, corneal curvature radius (CCR) and axial length. Central (2-mm diameter area), para-central (2- to 5-mm diameter area), and peripheral (5- to 6-mm diameter area) CET in the superior, superotemporal, temporal, inferotemporal, inferior, inferonasal, nasal, superonasal cornea; minimum, maximum, range, and standard deviation of CET within the 5-mm diameter area were recorded. The CET was thinner in the superior than in the inferior and was thinner in the temporal than in the nasal. The maximum CET was located in the inferior zone, and the minimum CET was in the superior zone. A thicker central CET was associated with male gender (p = 0.009) and older age (p = 0.037) but not with CCR (p = 0.061), axial length (p = 0.253), or refraction (p = 0.351) in the multiple regression analyses. CCR, age, and gender were correlated with para-central and peripheral CET.

  19. Variations in the size of focal nodular hyperplasia on magnetic resonance imaging.

    PubMed

    Ramírez-Fuentes, C; Martí-Bonmatí, L; Torregrosa, A; Del Val, A; Martínez, C

    2013-01-01

    To evaluate the changes in the size of focal nodular hyperplasia (FNH) during long-term magnetic resonance imaging (MRI) follow-up. We reviewed 44 FNHs in 30 patients studied with MRI with at least two MRI studies at least 12 months apart. We measured the largest diameter of the lesion (inmm) in contrast-enhanced axial images and calculated the percentage of variation as the difference between the maximum diameter in the follow-up and the maximum diameter in the initial study. We defined significant variation in size as variation greater than 20%. We also analyzed predisposing hormonal factors. The mean interval between the two imaging studies was 35±2 months (range: 12-94). Most lesions (80%) remained stable during follow-up. Only 9 of the 44 lesions (20%) showed a significant variation in diameter: 7 (16%) decreased in size and 2 (4%) increased, with variations that reached the double of the initial size. The change in size was not related to pregnancy, menopause, or the use of birth control pills or corticoids. Changes in the size of FNHs during follow-up are relatively common and should not lead to a change in the diagnosis. These variations in size seem to be independent of hormonal factors that are considered to predispose. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.

  20. A computational study of crimping and expansion of bioresorbable polymeric stents

    NASA Astrophysics Data System (ADS)

    Qiu, T. Y.; Song, M.; Zhao, L. G.

    2017-10-01

    This paper studied the mechanical performance of four bioresorbable PLLA stents, i.e., Absorb, Elixir, Igaki-Tamai and RevaMedical, during crimping and expansion using the finite element method. Abaqus CAE was used to create the geometrical models for the four stents. A tri-folded balloon was created using NX software. For the stents, elastic-plastic behaviour was used, with hardening implemented by considering the increase of yield stress with the plastic strain. The tri-folded balloon was treated as linear elastic. To simulate the crimping of stents, a set of 12 rigid plates were generated around the stents with a radially enforced displacement. During crimping, the stents were compressed from a diameter of 3 mm to 1.2 mm, with the maximum stress developed at both inner and outer sides of the U-bends. During expansion, the stent inner diameter increased to 3 mm at the peak pressure and then recoiled to different final diameters after balloon deflation due to different stent designs. The maximum stress was found again at the U-bends of stents. Diameter change, recoiling effect and radial strength/stiffness were also compared for the four stents to assess the effect of design variation on stent performance. The effect of loading rate on stent deformation was also simulated by considering the time-dependent plastic behaviour of polymeric material.

Top