Sample records for measured response function

  1. Responsiveness of outcome measures for upper limb prosthetic rehabilitation.

    PubMed

    Resnik, Linda; Borgia, Matthew

    2016-02-01

    There is limited research on responsiveness of prosthetic rehabilitation outcome measures. To examine responsiveness of the Box and Block test, Jebsen-Taylor Hand Function tests, Upper Extremity Functional Scale, University of New Brunswick skill and spontaneity tests, Activity Measure for Upper Limb Amputation, and the Patient-Specific Functional Scale. This was a quasi-experimental study with repeated measurements in a convenience sample of upper limb amputees. Measures were collected before, during, and after training with the DEKA Arm. Largest effect sizes were observed for Patient-Specific Functional Scale (effect size: 1.59, confidence interval: 1.00, 2.14), Activity Measure for Upper Limb Amputation (effect size: 1.33, confidence interval: 0.73, 1.90), and University of New Brunswick skill test (effect size: 1.18, confidence interval: 0.61, 1.73). Other measures that were responsive to change were Box and Block test, Jebsen-Taylor Hand Function light and heavy can tests, and University of New Brunswick spontaneity test. Responsiveness and pattern of responsiveness varied by prosthetic level. The Box and Block test, Jebsen-Taylor Hand Function light and heavy can tests, University of New Brunswick skill and spontaneity tests, Activities Measure for Upper Limb Amputation, and the Patient-Specific Functional Scale were responsive to change during prosthetic training. These findings have implications for choice of measures for research and practice and inform clinicians about the amount of training necessary to maximize outcomes with the DEKA Arm. Findings on responsiveness of outcome measures have implications for the choice of measures for clinical trials and practice. Findings regarding the responsiveness to change over the course of training can inform clinicians about the amount of training that may be necessary to maximize specific outcomes with the DEKA Arm. © The International Society for Prosthetics and Orthotics 2014.

  2. Responsiveness of pain and disability measures for chronic whiplash.

    PubMed

    Stewart, Mark; Maher, Christopher G; Refshauge, Kathryn M; Bogduk, Nikolai; Nicholas, Michael

    2007-03-01

    Cohort study. To evaluate the responsiveness of common pain and disability measures in a cohort of patients with chronic whiplash. Pain and disability are routinely measured in clinical practice and clinical research. However, to date, a head-to-head comparison of competing measures for whiplash patients has not been performed. Pain (pain intensity, bothersomeness, and SF-36 bodily pain score) and disability (Patient Specific Functional Scale, Neck Disability Index, Functional Rating Index, Copenhagen Scale, and SF-36 physical summary) measures were completed by 132 patients with chronic whiplash at baseline and then again after 6 weeks together with an 11-point global perceived effect scale. Internal responsiveness was evaluated by calculating effect sizes and standardized response means, and external responsiveness by correlating change scores with global perceived effect scores and by ROC curves. The ranking of responsiveness was consistent across the different analyses. Pain bothersomeness was more responsive than pain intensity, which was more responsive than the SF-36 pain measure. The Patient Specific Functional Scale was the most responsive disability measure, followed by the spine-specific measures, with the SF-36 physical summary measure the least responsive. Pain bothersomeness and the Patient Specific Functional Scale provide the most responsive measures of pain and disability, respectively, in patients with chronic whiplash.

  3. Method for suppressing noise in measurements

    NASA Technical Reports Server (NTRS)

    Carson, Paul L. (Inventor); Madsen, Louis A. (Inventor); Leskowitz, Garett M. (Inventor); Weitekamp, Daniel P. (Inventor)

    2000-01-01

    Methods for suppressing noise in measurements by correlating functions based on at least two different measurements of a system at two different times. In one embodiment, a measurement operation is performed on at least a portion of a system that has a memory. A property of the system is measured during a first measurement period to produce a first response indicative of a first state of the system. Then the property of the system is measured during a second measurement period to produce a second response indicative of a second state of the system. The second measurement is performed after an evolution duration subsequent to the first measurement period when the system still retains a degree of memory of an aspect of the first state. Next, a first function of the first response is combined with a second function of the second response to form a second-order correlation function. Information of the system is then extracted from the second-order correlation function.

  4. Single-joint outcome measures: preliminary validation of patient-reported outcomes and physical examination.

    PubMed

    Heald, Alison E; Fudman, Edward J; Anklesaria, Pervin; Mease, Philip J

    2010-05-01

    To assess the validity, responsiveness, and reliability of single-joint outcome measures for determining target joint (TJ) response in patients with inflammatory arthritis. Patient-reported outcomes (PRO), consisting of responses to single questions about TJ global status on a 100-mm visual analog scale (VAS; TJ global score), function on a 100-mm VAS (TJ function score), and pain on a 5-point Likert scale (TJ pain score) were piloted in 66 inflammatory arthritis subjects in a phase 1/2 clinical study of an intraarticular gene transfer agent and compared to physical examination measures (TJ swelling, TJ tenderness) and validated function questionnaires (Disabilities of the Arm, Shoulder and Hand scale, Rheumatoid Arthritis Outcome Score, and the Health Assessment Questionnaire). Construct validity was assessed by evaluating the correlation between the single-joint outcome measures and validated function questionnaires using Spearman's rank correlation. Responsiveness or sensitivity to change was assessed through calculating effect size and standardized response means (SRM). Reliability of physical examination measures was assessed by determining interobserver agreement. The single-joint PRO were highly correlated with each other and correlated well with validated functional measures. The TJ global score exhibited modest effect size and modest SRM that correlated well with the patient's assessment of response on a 100-mm VAS. Physical examination measures exhibited high interrater reliability, but correlated less well with validated functional measures and the patient's assessment of response. Single-joint PRO, particularly the TJ global score, are simple to administer and demonstrate construct validity and responsiveness in patients with inflammatory arthritis. (ClinicalTrials.gov identifier NCT00126724).

  5. Determination of a response function of a thermocouple using a short acoustic pulse.

    PubMed

    Tashiro, Yusuke; Biwa, Tetsushi; Yazaki, Taichi

    2007-04-01

    This paper reports on an experimental technique to determine a response function of a thermocouple using a short acoustic pulse wave. A pulse of 10 ms is generated in a tube filled with 1 bar helium gas. The temperature is measured using the thermocouple. The reference temperature is deduced from the measured pressure on the basis of a laminar oscillating flow theory. The response function of the thermocouple is obtained as a function of frequency below 50 Hz through a comparison between the measured and reference temperatures.

  6. Test procedures and performance measures sensitive to automobile steering dynamics. [considering operator/vehicle responses

    NASA Technical Reports Server (NTRS)

    Klein, R. H.; Mcruer, D. T.; Weir, D.

    1975-01-01

    A maneuver complex and related performance measures used to evaluate driver/vehicle system responses as effected by variations in the directional response characteristics of passenger cars are described. The complex consists of normal and emergency maneuvers (including random and discrete disturbances) which, taken as a whole, represent all classes of steering functions and all modes of driver response behavior. Measures of driver/vehicle system response and performance in regulation tasks included direct describing function measurements and rms yaw velocity. In transient maneuvers, measures such as steering activity and cone strikes were used.

  7. Customized acoustic transform functions and their accuracy at predicting real-ear hearing aid performance.

    PubMed

    Munro, K J; Hatton, N

    2000-02-01

    The purpose of the study was to evaluate the validity of predicting the real-ear aided response by adding customized acoustic transform functions to the performance of a hearing aid in a 2-cc coupler. The real-ear hearing aid response, the real-ear-to-coupler difference (RECD/HA2), and field to behind-the-ear microphone transfer functions were measured in both ears of 24 normally hearing subjects using probe-tube microphone equipment. The RECD/HA2 transform function was obtained using both insert earphones and with the hearing aid/ pressure comparison method. An RECD/HA2 transfer function was also obtained with a customized earmold, ER-3A foam tip, and an oto-admittance tip. Validity estimates were calculated as the difference between the derived and measured real-ear response. The derived response was generally within 5 dB of the measured real-ear response when it incorporated an RECD/HA2 transform function obtained with a customized earmold for the specific ear in question. Discrepancies increased when the RECD/HA2 transfer function was obtained from the same subject but the opposite ear. There were significant differences between the RECD/HA2 transform function obtained with customized and temporary earmolds. As a result, the derived response incorporating these transforms differed significantly from the measured real-ear response obtained with the customized earmold. The insert earphone and the hearing aid RECD/HA2 transfer function were equally valid. The derived response may be used as a substitute for in situ hearing aid response procedures when it incorporates acoustic transform functions obtained with a customized earmold from the specific ear in question.

  8. Field camera measurements of gradient and shim impulse responses using frequency sweeps.

    PubMed

    Vannesjo, S Johanna; Dietrich, Benjamin E; Pavan, Matteo; Brunner, David O; Wilm, Bertram J; Barmet, Christoph; Pruessmann, Klaas P

    2014-08-01

    Applications of dynamic shimming require high field fidelity, and characterizing the shim field dynamics is therefore necessary. Modeling the system as linear and time-invariant, the purpose of this work was to measure the impulse response function with optimal sensitivity. Frequency-swept pulses as inputs are analyzed theoretically, showing that the sweep speed is a key factor for the measurement sensitivity. By adjusting the sweep speed it is possible to achieve any prescribed noise profile in the measured system response. Impulse response functions were obtained for the third-order shim system of a 7 Tesla whole-body MR scanner. Measurements of the shim fields were done with a dynamic field camera, yielding also cross-term responses. The measured shim impulse response functions revealed system characteristics such as response bandwidth, eddy currents and specific resonances, possibly of mechanical origin. Field predictions based on the shim characterization were shown to agree well with directly measured fields, also in the cross-terms. Frequency sweeps provide a flexible tool for shim or gradient system characterization. This may prove useful for applications involving dynamic shimming by yielding accurate estimates of the shim fields and a basis for setting shim pre-emphasis. Copyright © 2013 Wiley Periodicals, Inc.

  9. Sexual Assertiveness Mediates the Associations Between Partner Facilitative Responses and Sexual Outcomes in Women With Provoked Vestibulodynia.

    PubMed

    McNicoll, Gabrielle; Corsini-Munt, Serena; O Rosen, Natalie; McDuff, Pierre; Bergeron, Sophie

    2017-10-03

    Provoked vestibulodynia (PVD) is a recurrent idiopathic vulvo-vaginal pain associated with negative sexual and psychological consequences. Facilitative partner responses to pain are currently receiving empirical attention because they are positively associated with women's sexual outcomes. However, the mechanisms through which facilitative responses to pain are associated with these outcomes have not been examined. One potential mechanism is sexual assertiveness, which has been found to be associated with better sexual function and satisfaction in women with PVD. The present study examined whether women's sexual assertiveness mediated the association between women's perception of facilitative partner responses and women's sexual function and satisfaction. Women (N = 140) with PVD symptomatology completed self-reported questionnaires evaluating their perception of their partners' facilitative responses, and their own sexual assertiveness, sexual function, and sexual satisfaction. Dependent measures were sexual function measured by the Female Sexual Function Index and sexual satisfaction assessed by the Global Measure of Sexual Satisfaction Scale. Results indicated that women's higher sexual assertiveness mediated the association between their greater perceived facilitative partner responses and their improved sexual function and satisfaction. Findings suggest a potential mechanism through which partner responses may be associated with women's sexual outcomes.

  10. Measurements of the response function and the detection efficiency of an NE213 scintillator for neutrons between 20 and 65 MeV

    NASA Astrophysics Data System (ADS)

    Meigo, S.

    1997-02-01

    For neutrons 25, 30 and 65 MeV, the response functions and detection efficiencies of an NE213 liquid scintillator were measured. Quasi-monoenergetic neutrons produced by the 7Li(p,N 0.1) reaction were employed for the measurement and the absolute flux of incident neutrons was determined within 4% accuracy using a proton recoil telescope. Response functions and detection efficiencies calculated with the Monte Carlo codes, CECIL and SCINFUL, were compared with the measured data. It was found that response functions calculated with SCINFUL agreed better with experimental ones than those with CECIL, however, the deuteron light output used in SCINFUL was too low. The response functions calculated with a revised SCINFUL agreed with the experimental ones quite well even for the deuteron bump and peak due to the C(n,d 0) reaction. It was confirmed that the detection efficiencies calculated with the original and the revised SCINFULs agreed with the experimental data within the experimental error, while those with CECIL were about 20% higher in the energy region above 30 MeV.

  11. Detector response function of an energy-resolved CdTe single photon counting detector.

    PubMed

    Liu, Xin; Lee, Hyoung Koo

    2014-01-01

    While spectral CT using single photon counting detector has shown a number of advantages in diagnostic imaging, knowledge of the detector response function of an energy-resolved detector is needed to correct the signal bias and reconstruct the image more accurately. The objective of this paper is to study the photo counting detector response function using laboratory sources, and investigate the signal bias correction method. Our approach is to model the detector response function over the entire diagnostic energy range (20 keV

  12. Response diversity determines the resilience of ecosystems to environmental change.

    PubMed

    Mori, Akira S; Furukawa, Takuya; Sasaki, Takehiro

    2013-05-01

    A growing body of evidence highlights the importance of biodiversity for ecosystem stability and the maintenance of optimal ecosystem functionality. Conservation measures are thus essential to safeguard the ecosystem services that biodiversity provides and human society needs. Current anthropogenic threats may lead to detrimental (and perhaps irreversible) ecosystem degradation, providing strong motivation to evaluate the response of ecological communities to various anthropogenic pressures. In particular, ecosystem functions that sustain key ecosystem services should be identified and prioritized for conservation action. Traditional diversity measures (e.g. 'species richness') may not adequately capture the aspects of biodiversity most relevant to ecosystem stability and functionality, but several new concepts may be more appropriate. These include 'response diversity', describing the variation of responses to environmental change among species of a particular community. Response diversity may also be a key determinant of ecosystem resilience in the face of anthropogenic pressures and environmental uncertainty. However, current understanding of response diversity is poor, and we see an urgent need to disentangle the conceptual strands that pervade studies of the relationship between biodiversity and ecosystem functioning. Our review clarifies the links between response diversity and the maintenance of ecosystem functionality by focusing on the insurance hypothesis of biodiversity and the concept of functional redundancy. We provide a conceptual model to describe how loss of response diversity may cause ecosystem degradation through decreased ecosystem resilience. We explicitly explain how response diversity contributes to functional compensation and to spatio-temporal complementarity among species, leading to long-term maintenance of ecosystem multifunctionality. Recent quantitative studies suggest that traditional diversity measures may often be uncoupled from measures (such as response diversity) that may be more effective proxies for ecosystem stability and resilience. Certain conclusions and recommendations of earlier studies using these traditional measures as indicators of ecosystem resilience thus may be suspect. We believe that functional ecology perspectives incorporating the effects and responses of diversity are essential for development of management strategies to safeguard (and restore) optimal ecosystem functionality (especially multifunctionality). Our review highlights these issues and we envision our work generating debate around the relationship between biodiversity and ecosystem functionality, and leading to improved conservation priorities and biodiversity management practices that maximize ecosystem resilience in the face of uncertain environmental change. © 2012 The Authors. Biological Reviews © 2012 Cambridge Philosophical Society.

  13. Edge analyzing properties of center/surround response functions in cybernetic vision

    NASA Technical Reports Server (NTRS)

    Jobson, D. J.

    1984-01-01

    The ability of center/surround response functions to make explicit high resolution spatial information in optical images was investigated by performing convolutions of two dimensional response functions and image intensity functions (mainly edges). The center/surround function was found to have the unique property of separating edge contrast from shape variations and of providing a direct basis for determining contrast and subsequently shape of edges in images. Computationally simple measures of contrast and shape were constructed for potential use in cybernetic vision systems. For one class of response functions these measures were found to be reasonably resilient for a range of scan direction and displacements of the response functions relative to shaped edges. A pathological range of scan directions was also defined and methods for detecting and handling these cases were developed. The relationship of these results to biological vision is discussed speculatively.

  14. Standardization of Broadband UV Measurements for 365 nm LED Sources

    PubMed Central

    Eppeldauer, George P.

    2012-01-01

    Broadband UV measurements are evaluated when UV-A irradiance meters measure optical radiation from 365 nm UV sources. The CIE standardized rectangular-shape UV-A function can be realized only with large spectral mismatch errors. The spectral power-distribution of the 365 nm excitation source is not standardized. Accordingly, the readings made with different types of UV meters, even if they measure the same UV source, can be very different. Available UV detectors and UV meters were measured and evaluated for spectral responsivity. The spectral product of the source-distribution and the meter’s spectral-responsivity were calculated for different combinations to estimate broad-band signal-measurement errors. Standardization of both the UV source-distribution and the meter spectral-responsivity is recommended here to perform uniform broad-band measurements with low uncertainty. It is shown what spectral responsivity function(s) is needed for new and existing UV irradiance meters to perform low-uncertainty broadband 365 nm measurements. PMID:26900516

  15. An investigation of the validity of six measures of physical function in people awaiting joint replacement surgery of the hip or knee.

    PubMed

    Gill, Stephen D; de Morton, Natalie A; Mc Burney, Helen

    2012-10-01

    To assess and compare the validity of six physical function measures in people awaiting hip or knee joint replacement. Eighty-two people awaiting hip or knee replacement were assessed using six physical function measures including the WOMAC Function scale, SF-36 Physical Function scale, SF-36 Physical Component Summary scale, Patient Specific Functional Scale, 30-second chair stand test, and 50-foot timed walk. Validity was assessed using a head-to-head comparison design. Convergent validity was demonstrated with significant correlations between most measures (Spearman's rho 0.22 to 0.71). The Patient Specific Functional Scale had the lowest correlations with other measures of physical function. Discriminant validity was demonstrated with low correlations between mental health and physical function scores (Spearman's rho -0.12 to 0.33). Only the WOMAC Function scale, 30-second chair stand test, and 50-foot timed walk demonstrated known groups validity when scores for participants who walked with a gait aid were compared with those who did not. Standardized response means and Guyatt's responsiveness indexes indicated that the SF-36 was the least responsive measure. For those awaiting joint replacement surgery of the hip or knee, the current investigation found that the WOMAC Function scale, 30-second chair stand test, and 50-foot timed walk demonstrated the most evidence of validity. The Patient Specific Functional Scale might complement other measures by capturing a different aspect of physical function.

  16. Measurements of response functions of EJ-299-33A plastic scintillator for fast neutrons

    NASA Astrophysics Data System (ADS)

    Hartman, J.; Barzilov, A.; Peters, E. E.; Yates, S. W.

    2015-12-01

    Monoenergetic neutron response functions were measured for an EJ-299-33A plastic scintillator. The 7-MV Van de Graaff accelerator at the University of Kentucky Accelerator Laboratory was used to produce proton and deuteron beams for reactions with gaseous tritium and deuterium targets, yielding monoenergetic neutrons by means of the 3H(p,n)3He, 2H(d,n)3He, and 3H(d,n)4He reactions. The neutron energy was selected by tuning the charged-particle's energy and using the angular dependence of the neutron emission. The resulting response functions were measured for 0.1-MeV steps in neutron energy from 0.1 MeV to 8.2 MeV and from 12.2 MeV to 20.2 MeV. Experimental data were processed using a procedure for digital pulse-shape discrimination, which allowed characterization of the response functions of the plastic scintillator to neutrons only. The response functions are intended for use in neutron spectrum unfolding methods.

  17. Flow-mediated changes in pulse wave velocity: a new clinical measure of endothelial function.

    PubMed

    Naka, Katerina K; Tweddel, Ann C; Doshi, Sagar N; Goodfellow, Jonathan; Henderson, Andrew H

    2006-02-01

    To test whether measuring hyperaemic changes in pulse wave velocity (PWV) could be used as a new method of assessing endothelial function for use in clinical practice. Flow-mediated changes in vascular tone may be used to assess endothelial function and may be induced by distal hyperaemia, while endothelium-mediated changes in vascular tone can influence PWV. These three known principles were combined to provide and test a novel method of measuring endothelial function by the acute effects of distal hyperaemia on upper and lower limb PWV (measured by a recently developed method). Flow-mediated changes in upper and lower limb PWV were compared in 17 healthy subjects and seven patients with stable chronic heart failure (CHF), as a condition where endothelial function is impaired but endothelium-independent dilator responses are retained. Corroborative measurements of PWV and brachial artery diameter responses to endothelium-dependent and -independent pharmacological stimuli were performed in a further eight healthy subjects. Flow-mediated reduction of PWV (by 14% with no change in blood pressure) was found in normal subjects but was almost abolished in patients with CHF. PWV responses appear to be inversely related to and relatively greater than brachial artery diameter responses. The method may offer potential advantages of practical use and sensitivity over conduit artery diameter responses to measure endothelial dysfunction.

  18. Comparison of reliability and responsiveness of patient-reported clinical outcome measures in knee osteoarthritis rehabilitation.

    PubMed

    Williams, Valerie J; Piva, Sara R; Irrgang, James J; Crossley, Chad; Fitzgerald, G Kelley

    2012-08-01

    Secondary analysis, pretreatment-posttreatment observational study. To compare the reliability and responsiveness of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Knee Outcome Survey activities of daily living subscale (KOS-ADL), and the Lower Extremity Functional Scale (LEFS) in individuals with knee osteoarthritis (OA). The WOMAC is the current standard in patient-reported measures of function in patients with knee OA. The KOS-ADL and LEFS were designed for potential use in patients with knee OA. If the KOS-ADL and LEFS are to be considered viable alternatives to the WOMAC for measuring patient-reported function in individuals with knee OA, they should have measurement properties comparable to the WOMAC. It would also be important to determine whether either of these instruments may be superior to the WOMAC in terms of reliability or responsiveness in this population. Data from 168 subjects with knee OA, who participated in a rehabilitation program, were used in the analyses. Reliability and responsiveness of each outcome measure were estimated at follow-ups of 2, 6, and 12 months. Reliability was estimated by calculating the intraclass correlation coefficient (ICC2,1) for subjects who were unchanged in status from baseline at each follow-up time, based on a global rating of change score. To examine responsiveness, the standard error of the measurement, minimal detectable change, minimal clinically important difference, and the Guyatt responsiveness index were calculated for each outcome measure at each follow-up time. All 3 outcome measures demonstrated reasonable reliability and responsiveness to change. Reliability and responsiveness tended to decrease somewhat with increasing follow-up time. There were no substantial differences between outcome measures for reliability or any of the 3 measures of responsiveness at any follow-up time. The results do not indicate that one outcome measure is more reliable or responsive than another when applied to subjects with knee OA. We believe that all 3 instruments are appropriate outcome measures to examine change in functional status of patients with knee OA.

  19. Computer method for identification of boiler transfer functions

    NASA Technical Reports Server (NTRS)

    Miles, J. H.

    1971-01-01

    An iterative computer method is described for identifying boiler transfer functions using frequency response data. An objective penalized performance measure and a nonlinear minimization technique are used to cause the locus of points generated by a transfer function to resemble the locus of points obtained from frequency response measurements. Different transfer functions can be tried until a satisfactory empirical transfer function to the system is found. To illustrate the method, some examples and some results from a study of a set of data consisting of measurements of the inlet impedance of a single tube forced flow boiler with inserts are given.

  20. Functioning in the Real World: Using Storytelling to Improve Validity in the Assessment of Executive Functions.

    PubMed

    Annotti, Lee A; Teglasi, Hedwig

    2017-01-01

    Real-world contexts differ in the clarity of expectations for desired responses, as do assessment procedures, ranging along a continuum from maximal conditions that provide well-defined expectations to typical conditions that provide ill-defined expectations. Executive functions guide effective social interactions, but relations between them have not been studied with measures that are matched in the clarity of response expectations. In predicting teacher-rated social competence (SC) from kindergarteners' performance on tasks of executive functions (EFs), we found better model-data fit indexes when both measures were similar in the clarity of response expectations for the child. The maximal EF measure, the Developmental Neuropsychological Assessment, presents well-defined response expectations, and the typical EF measure, 5 scales from the Thematic Apperception Test (TAT), presents ill-defined response expectations (i.e., Abstraction, Perceptual Integration, Cognitive-Experiential Integration, and Associative Thinking). To assess SC under maximal and typical conditions, we used 2 teacher-rated questionnaires, with items, respectively, that emphasize well-defined and ill-defined expectations: the Behavior Rating Inventory: Behavioral Regulation Index and the Social Skills Improvement System: Social Competence Scale. Findings suggest that matching clarity of expectations improves generalization across measures and highlight the usefulness of the TAT to measure EF.

  1. Do parent protective responses mediate the relation between parent distress and child functional disability among children with chronic pain?

    PubMed

    Sieberg, Christine B; Williams, Sara; Simons, Laura E

    2011-10-01

    To examine whether protective parent responses mediate the relation between parent distress and child functioning. At a pain clinic evaluation, 157 families participated. Parents completed measures of global distress (BSI-18), distress in the context of their child's pain (BAP-PIQ), and protective responses to their child's pain. Children completed measures of functional disability and pain. BAP-PIQ subscales were significantly associated with child functional disability, whereas BSI subscales were unrelated. Protective parent responses partially mediated the relation between parent distress and child functional disability for depression, anxiety, and catastrophizing. However, parent protective behavior fully mediated the relationship between parent helplessness and child functional disability, indicating that feelings of parent helplessness did not uniquely contribute to child functional disability. Discussion Results suggest that when treating youth with chronic pain, parental distress in the context of children's pain needs to be addressed.

  2. Responsiveness of physical function outcomes following physiotherapy intervention for osteoarthritis of the knee: an outcome comparison study.

    PubMed

    French, Helen P; Fitzpatrick, Martina; FitzGerald, Oliver

    2011-12-01

    To compare the responsiveness of two self-report measures and three physical performance measures of function following physiotherapy for osteoarthritis of the knee. Single centre study in acute hospital setting. Patients referred for physiotherapy with osteoarthritis of the knee were recruited. The Western Ontario and McMaster Universities (WOMAC), Lequesne Algofunctional Index (LAI), timed-up-and-go test (TUGT), timed-stand test (TST) and six-minute walk test (6MWT) were administered at first and final physiotherapy visits. Wilcoxon Signed Rank tests were used to determine the effect of physiotherapy on each outcome. Responsiveness was calculated using effect size, standardised response mean and a median-based measure of responsiveness due to some outlying data. Thirty-nine patients with a mean age of 65.3 (standard deviation 6.9) years were investigated before and after a course of exercise-based physiotherapy. There was a significant improvement in all outcomes except the WOMAC scores. All measures demonstrated small effect sizes for all statistics (<0.50), except the 6MWT which was in the moderate range for one of the indices (standardised response mean 0.54). The LAI was more responsive than the WOMAC total score and the WOMAC physical function subscale for all responsiveness statistics, whilst the 6MWT was more responsive than the TST and the TUGT. The median-based effect size index produced the smallest effect sizes for all measures (0.1 to 0.43). These results can be used to guide decision making about which physical function outcome measures should be used to evaluate effectiveness of rehabilitation of people with osteoarthritis of the knee at group level in a clinical setting. Copyright © 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  3. Improving measurement of injection drug risk behavior using item response theory.

    PubMed

    Janulis, Patrick

    2014-03-01

    Recent research highlights the multiple steps to preparing and injecting drugs and the resultant viral threats faced by drug users. This research suggests that more sensitive measurement of injection drug HIV risk behavior is required. In addition, growing evidence suggests there are gender differences in injection risk behavior. However, the potential for differential item functioning between genders has not been explored. To explore item response theory as an improved measurement modeling technique that provides empirically justified scaling of injection risk behavior and to examine for potential gender-based differential item functioning. Data is used from three studies in the National Institute on Drug Abuse's Criminal Justice Drug Abuse Treatment Studies. A two-parameter item response theory model was used to scale injection risk behavior and logistic regression was used to examine for differential item functioning. Item fit statistics suggest that item response theory can be used to scale injection risk behavior and these models can provide more sensitive estimates of risk behavior. Additionally, gender-based differential item functioning is present in the current data. Improved measurement of injection risk behavior using item response theory should be encouraged as these models provide increased congruence between construct measurement and the complexity of injection-related HIV risk. Suggestions are made to further improve injection risk behavior measurement. Furthermore, results suggest direct comparisons of composite scores between males and females may be misleading and future work should account for differential item functioning before comparing levels of injection risk behavior.

  4. Generation of the neutron response function of an NE213 scintillator for fusion applications

    NASA Astrophysics Data System (ADS)

    Binda, F.; Eriksson, J.; Ericsson, G.; Hellesen, C.; Conroy, S.; Nocente, M.; Sundén, E. Andersson; JET Contributors

    2017-09-01

    In this work we present a method to evaluate the neutron response function of an NE213 liquid scintillator. This method is particularly useful when the proton light yield function of the detector has not been measured, since it is based on a proton light yield function taken from literature, MCNPX simulations, measurements of gamma-rays from a calibration source and measurements of neutrons from fusion experiments with ohmic plasmas. The inclusion of the latter improves the description of the proton light yield function in the energy range of interest (around 2.46 MeV). We apply this method to an NE213 detector installed at JET, inside the radiation shielding of the magnetic proton recoil (MPRu) spectrometer, and present the results from the calibration along with some examples of application of the response function to perform neutron emission spectroscopy (NES) of fusion plasmas. We also investigate how the choice of the proton light yield function affects the NES analysis, finding that the result does not change significantly. This points to the fact that the method for the evaluation of the neutron response function is robust and gives reliable results.

  5. Clinical responsiveness of self-report functional assessment measures for children with juvenile idiopathic arthritis undergoing intraarticular corticosteroid injections.

    PubMed

    Brown, G Ted; Wright, F Virginia; Lang, Bianca A; Birdi, Nina; Oen, Kim; Stephens, Derek; McComas, Joan; Feldman, Brian M

    2005-12-15

    The Childhood Health Assessment Questionnaire (CHAQ), Juvenile Arthritis Functional Assessment Report (JAFAR), and Juvenile Arthritis Functional Status Index (JASI) are widely used functional measures for juvenile idiopathic arthritis (JIA) that differ in content, format, and completion time. We compared the responsiveness and child-parent agreement of the JAFAR, CHAQ, and JASI in a prospective, multicenter study. Children and adolescents from 5 rheumatology centers were enrolled. Subjects were about to undergo therapy (intraarticular corticosteroid injections [IAS] and methotrexate or hip surgery (MTX/hip]) expected to produce a functional improvement. All subjects were studied before the intervention and at 6 weeks and 6 months posttreatment. At each study visit, the 3 measures were administered in randomized, balanced order to both parents and children. A total of 92 subjects (mean age 12.8 years) were enrolled in the study, 74 of which were in the IAS group. The responsiveness of all 3 measures was moderate to strong. The standardized response mean at 6 weeks for the IAS group on the JAFAR, CHAQ, and JASI was 0.41 (95% confidence interval [95% CI] 0.18, 0.64), 0.70 (95% CI 0.47, 0.93), and 0.36 (95% CI 0.13, 0.59), respectively. The CHAQ was somewhat more responsive to change at 6 weeks (IAS group: relative efficiency 0.34 [JAFAR], 0.27 [JASI]), but less responsive at 6 months (MTX/hip group: relative efficiency 5.1 [JAFAR], 3.9 [JASI]). All 3 questionnaires showed acceptable parent-child agreement, and overall, there were few differences between the 3 questionnaires. The functional outcome measures currently used for JIA are all adequately responsive for use in trials or in the clinic setting. The choice of which measure to use should therefore be based on the time available for completion, the intended clinical/research use, and the depth of content required.

  6. Identification of boiler inlet transfer functions and estimation of system parameters

    NASA Technical Reports Server (NTRS)

    Miles, J. H.

    1972-01-01

    An iterative computer method is described for identifying boiler transfer functions using frequency response data. An objective penalized performance measure and a nonlinear minimization technique are used to cause the locus of points generated by a transfer function to resemble the locus of points obtained from frequency response measurements. Different transfer functions can be tried until a satisfactory empirical transfer function of the system is found. To illustrate the method, some examples and some results from a study of a set of data consisting of measurements of the inlet impedance of a single tube forced flow boiler with inserts are given.

  7. Intrapixel measurement techniques on large focal plane arrays for astronomical applications: a comparative study

    NASA Astrophysics Data System (ADS)

    Ketchazo, C.; Viale, T.; Boulade, O.; de la Barrière, F.; Dubreuil, D.; Mugnier, L.; Moreau, V.; Guérineau, N.; Mulet, P.; Druart, G.; Delisle, C.

    2017-09-01

    The intrapixel response is the signal detected by a single pixel illuminated by a Dirac distribution as a function of the position of this Dirac inside this pixel. It is also known as the pixel response function (PRF). This function measures the sensitivity variation at the subpixel scale and gives a spatial map of the sensitivity across a pixel.

  8. Measurement properties of gait-related outcomes in youth with neuromuscular diagnoses: a systematic review.

    PubMed

    Ammann-Reiffer, Corinne; Bastiaenen, Caroline H G; de Bie, Rob A; van Hedel, Hubertus J A

    2014-08-01

    Sound measurement properties of outcome tools are essential when evaluating outcomes of an intervention, in clinical practice and in research. The purpose of this study was to review the evidence on reliability, measurement error, and responsiveness of measures of gait function in children with neuromuscular diagnoses. The MEDLINE, CINAHL, EMBASE, and PsycINFO databases were searched up to June 15, 2012. Studies evaluating reliability, measurement error, or responsiveness of measures of gait function in 1- to 18-year-old children and youth with neuromuscular diagnoses were included. Quality of the studies was independently rated by 2 raters using a modified COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) checklist. Studies with a fair quality rating or better were considered for best evidence synthesis. Regarding the methodological quality, 32 out of 35 reliability studies, all of the 13 measurement error studies, and 5 out of 10 responsiveness studies were of fair or good quality. Best evidence synthesis revealed moderate to strong evidence for reliability for several measures in children and youth with cerebral palsy (CP) but was limited or unknown in other diagnoses. The Functional Mobility Scale (FMS) and the Gross Motor Function Measure (GMFM) dimension E showed limited positive evidence for responsiveness in children with CP, but it was unknown or controversial in other diagnoses. No information was reported on the minimal important change; thus, evidence on measurement error remained undetermined. As studies on validity were not included in the review, a comprehensive appraisal of the best available gait-related outcome measure per diagnosis is not possible. There is moderate to strong evidence on reliability for several measures of gait function in children and youth with CP, whereas evidence on responsiveness exists only for the FMS and the GMFM dimension E. © 2014 American Physical Therapy Association.

  9. Amplitude Frequency Response Measurement: A Simple Technique

    ERIC Educational Resources Information Center

    Satish, L.; Vora, S. C.

    2010-01-01

    A simple method is described to combine a modern function generator and a digital oscilloscope to configure a setup that can directly measure the amplitude frequency response of a system. This is achieved by synchronously triggering both instruments, with the function generator operated in the "Linear-Sweep" frequency mode, while the oscilloscope…

  10. Comparing the responsiveness of functional outcome assessment measures for trauma registries.

    PubMed

    Williamson, Owen D; Gabbe, Belinda J; Sutherland, Ann M; Wolfe, Rory; Forbes, Andrew B; Cameron, Peter A

    2011-07-01

    Measuring long-term disability and functional outcomes after major trauma is not standardized across trauma registries. An ideal measure would be responsive to change but not have significant ceiling effects. The aim of this study was to compare the responsiveness of the Glasgow Outcome Scale (GOS), GOS-Extended (GOSE), Functional Independence Measure (FIM), and modified FIM in major trauma patients, with and without significant head injuries. Patients admitted to two adult Level I trauma centers in Victoria, Australia, who survived to discharge from hospital, were aged 15 years to 80 years with a blunt mechanism of injury, and had an estimated Injury Severity Score >15 on admission, were recruited for this prospective study. The instruments were administered at baseline (hospital discharge) and by telephone interview 6 months after injury. Measures of responsiveness, including effect sizes, were calculated. Bootstrapping techniques, and floor and ceiling effects, were used to compare the measures. Two hundred forty-three patients participated, of which 234 patients (96%) completed the study. The GOSE and GOS were the most responsive instruments in this major trauma population with effect sizes of 5.3 and 4.4, respectively. The GOSE had the lowest ceiling effect (17%). The GOSE was the instrument with greatest responsiveness and the lowest ceiling effect in a major trauma population with and without significant head injuries and is recommended for use by trauma registries for monitoring functional outcomes and benchmarking care. The results of this study do not support the use of the modified FIM for this purpose.

  11. Laser-based irradiation apparatus and method to measure the functional dose-rate response of semiconductor devices

    DOEpatents

    Horn, Kevin M [Albuquerque, NM

    2008-05-20

    A broad-beam laser irradiation apparatus can measure the parametric or functional response of a semiconductor device to exposure to dose-rate equivalent infrared laser light. Comparisons of dose-rate response from before, during, and after accelerated aging of a device, or from periodic sampling of devices from fielded operational systems can determine if aging has affected the device's overall functionality. The dependence of these changes on equivalent dose-rate pulse intensity and/or duration can be measured with the apparatus. The synchronized introduction of external electrical transients into the device under test can be used to simulate the electrical effects of the surrounding circuitry's response to a radiation exposure while exposing the device to dose-rate equivalent infrared laser light.

  12. Neutron spectrometry in a mixed field of neutrons and protons with a phoswich neutron detector Part I: response functions for photons and neutrons of the phoswich neutron detector

    NASA Astrophysics Data System (ADS)

    Takada, M.; Taniguchi, S.; Nakamura, T.; Nakao, N.; Uwamino, Y.; Shibata, T.; Fujitaka, K.

    2001-06-01

    We have developed a phoswich neutron detector consisting of an NE213 liquid scintillator surrounded by an NE115 plastic scintillator to distinguish photon and neutron events in a charged-particle mixed field. To obtain the energy spectra by unfolding, the response functions to neutrons and photons were obtained by the experiment and calculation. The response functions to photons were measured with radionuclide sources, and were calculated with the EGS4-PRESTA code. The response functions to neutrons were measured with a white neutron source produced by the bombardment of 135 MeV protons onto a Be+C target using a TOF method, and were calculated with the SCINFUL code, which we revised in order to calculate neutron response functions up to 135 MeV. Based on these experimental and calculated results, response matrices for photons up to 20 MeV and neutrons up to 132 MeV could finally be obtained.

  13. Iterated intracochlear reflection shapes the envelopes of basilar-membrane click responses

    PubMed Central

    Shera, Christopher A.

    2015-01-01

    Multiple internal reflection of cochlear traveling waves has been argued to provide a plausible explanation for the waxing and waning and other temporal structures often exhibited by the envelopes of basilar-membrane (BM) and auditory-nerve responses to acoustic clicks. However, a recent theoretical analysis of a BM click response measured in chinchilla concludes that the waveform cannot have arisen via any equal, repetitive process, such as iterated intracochlear reflection [Wit and Bell (2015), J. Acoust. Soc. Am. 138, 94–96]. Reanalysis of the waveform contradicts this conclusion. The measured BM click response is used to derive the frequency-domain transfer function characterizing every iteration of the loop. The selfsame transfer function that yields waxing and waning of the BM click response also captures the spectral features of ear-canal stimulus-frequency otoacoustic emissions measured in the same animal, consistent with the predictions of multiple internal reflection. Small shifts in transfer-function phase simulate results at different measurement locations and reproduce the heterogeneity of BM click response envelopes observed experimentally. PMID:26723327

  14. Taking into account the impact of attrition on the assessment of response shift and true change: a multigroup structural equation modeling approach.

    PubMed

    Verdam, Mathilde G E; Oort, Frans J; van der Linden, Yvette M; Sprangers, Mirjam A G

    2015-03-01

    Missing data due to attrition present a challenge for the assessment and interpretation of change and response shift in HRQL outcomes. The objective was to handle such missingness and to assess response shift and 'true change' with the use of an attrition-based multigroup structural equation modeling (SEM) approach. Functional limitations and health impairments were measured in 1,157 cancer patients, who were treated with palliative radiotherapy for painful bone metastases, before [time (T) 0], every week after treatment (T1 through T12), and then monthly for up to 2 years (T13 through T24). To handle missing data due to attrition, the SEM procedure was extended to a multigroup approach, in which we distinguished three groups: short survival (3-5 measurements), medium survival (6-12 measurements), and long survival (>12 measurements). Attrition after third, sixth, and 13th measurement occasions was 11, 24, and 41 %, respectively. Results show that patterns of change in functional limitations and health impairments differ between patients with short, medium, or long survival. Moreover, three response-shift effects were detected: recalibration of 'pain' and 'sickness' and reprioritization of 'physical functioning.' If response-shift effects would not have been taken into account, functional limitations and health impairments would generally be underestimated across measurements. The multigroup SEM approach enables the analysis of data from patients with different patterns of missing data due to attrition. This approach does not only allow for detection of response shift and assessment of true change across measurements, but also allow for detection of differences in response shift and true change across groups of patients with different attrition rates.

  15. HEALTH SIGNIFICANCE OF PULMONARY FUNCTION TESTS

    EPA Science Inventory

    As the sensitivity and precision of functional tests improves, we become increasingly able to measure responses to pollutant exposures with little, if any, demonstrable health significance. Proper interpretation of such functional responses generally requires an ability to evalua...

  16. Distinguishing between learning and motivation in behavioral tests of the reinforcement sensitivity theory of personality.

    PubMed

    Smillie, Luke D; Dalgleish, Len I; Jackson, Chris J

    2007-04-01

    According to Gray's (1973) Reinforcement Sensitivity Theory (RST), a Behavioral Inhibition System (BIS) and a Behavioral Activation System (BAS) mediate effects of goal conflict and reward on behavior. BIS functioning has been linked with individual differences in trait anxiety and BAS functioning with individual differences in trait impulsivity. In this article, it is argued that behavioral outputs of the BIS and BAS can be distinguished in terms of learning and motivation processes and that these can be operationalized using the Signal Detection Theory measures of response-sensitivity and response-bias. In Experiment 1, two measures of BIS-reactivity predicted increased response-sensitivity under goal conflict, whereas one measure of BAS-reactivity predicted increased response-sensitivity under reward. In Experiment 2, two measures of BIS-reactivity predicted response-bias under goal conflict, whereas a measure of BAS-reactivity predicted motivation response-bias under reward. In both experiments, impulsivity measures did not predict criteria for BAS-reactivity as traditionally predicted by RST.

  17. Estimation of automobile-driver describing function from highway tests using the double steering wheel

    NASA Technical Reports Server (NTRS)

    Delp, P.; Crossman, E. R. F. W.; Szostak, H.

    1972-01-01

    The automobile-driver describing function for lateral position control was estimated for three subjects from frequency response analysis of straight road test results. The measurement procedure employed an instrumented full size sedan with known steering response characteristics, and equipped with a lateral lane position measuring device based on video detection of white stripe lane markings. Forcing functions were inserted through a servo driven double steering wheel coupling the driver to the steering system proper. Random appearing, Gaussian, and transient time functions were used. The quasi-linear models fitted to the random appearing input frequency response characterized the driver as compensating for lateral position error in a proportional, derivative, and integral manner. Similar parameters were fitted to the Gabor transformed frequency response of the driver to transient functions. A fourth term corresponding to response to lateral acceleration was determined by matching the time response histories of the model to the experimental results. The time histories show evidence of pulse-like nonlinear behavior during extended response to step transients which appear as high frequency remnant power.

  18. Foliar Temperature-Respiration Response Functions for Broad-Leaved Tree Species in the Southern Appalachians

    Treesearch

    Paul V. Bolstad; Katherine Mitchell; James M. Vose

    1999-01-01

    We measured leaf respiration in 18 eastern deciduous forest tree species to determine if there were differences in temperature-respiration response functions among species or among canopy positions. Leaf respiration rates were measured in situ an4 on detached branches for Acer pensylvanicum L., A. rubrum L., Betula...

  19. The motor function measure to study limitation of activity in children and adults with Charcot-Marie-Tooth disease.

    PubMed

    Allard, L; Rode, G; Jacquin-Courtois, S; Pouget, M C; Rippert, P; Hamroun, D; Poirot, I; Bérard, C; Vuillerot, C

    2014-12-01

    To study the applicability and responsiveness of the motor function measure (total score and sub-scores D1, D2 and D3) in patients with Charcot-Marie-Tooth disease. Two hundred and thirty-three patients aged 4-86 years were included in the descriptive study. Scores and sub-scores were analyzed by age and by disease subtypes. Sensitivity to change (responsiveness) was estimated in patients having had at least two evaluations with at least six months between the first and the second. Motor function measure scores decrease with age, especially sub-scores D1 and D3. There were no significant differences between the scores according to type of Charcot-Marie-Tooth disease. The scores were significantly higher for ambulatory than for non-ambulatory patients. Significant responsiveness was demonstrated only in type 2 Charcot-Marie-Tooth disease. Our results suggest that, especially for D1 and D3 sub-scores, the motor function measure is a reliable and valid outcome measure that can be usefully applied in longitudinal follow-up. Studies of longer duration could demonstrate its responsiveness in other Charcot-Marie-Tooth disease subtypes. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  20. Comparing light sensitivity, linearity and step response of electronic cameras for ophthalmology.

    PubMed

    Kopp, O; Markert, S; Tornow, R P

    2002-01-01

    To develop and test a procedure to measure and compare light sensitivity, linearity and step response of electronic cameras. The pixel value (PV) of digitized images as a function of light intensity (I) was measured. The sensitivity was calculated from the slope of the P(I) function, the linearity was estimated from the correlation coefficient of this function. To measure the step response, a short sequence of images was acquired. During acquisition, a light source was switched on and off using a fast shutter. The resulting PV was calculated for each video field of the sequence. A CCD camera optimized for the near-infrared (IR) spectrum showed the highest sensitivity for both, visible and IR light. There are little differences in linearity. The step response depends on the procedure of integration and read out.

  1. Utility of Functional Hemodynamics and Echocardiography to Aid Diagnosis and Management of Shock.

    PubMed

    McGee, William T; Raghunathan, Karthik; Adler, Adam C

    2015-12-01

    The utility of functional hemodynamics and bedside ultrasonography is increasingly recognized as advantageous for both improved diagnosis and management of shock states. In contrast to conventional "static" measures, "dynamic" hemodynamic measures and bedside imaging modalities enhance pathophysiology-based comprehensive understanding of shock states and the response to therapy. The current editions of major textbooks in the primary specialties--in which clinicians routinely encounter patients in shock--including surgery, anesthesia, emergency medicine, and internal medicine continue to incorporate traditional (conventional) descriptions of shock that use well-described (but potentially misleading) intravascular pressures to classify shock states. Reliance on such intravascular pressure measurements is not as helpful as newer "dynamic" functional measures including ultrasonography to both better assess volume responsiveness and biventricular cardiac function. This review thus emphasizes the application of current functional hemodynamics and ultrasonography to the diagnosis and management of shock as a contrast to conventional "static" pressure-based measures.

  2. Estimation of the auto frequency response function at unexcited points using dummy masses

    NASA Astrophysics Data System (ADS)

    Hosoya, Naoki; Yaginuma, Shinji; Onodera, Hiroshi; Yoshimura, Takuya

    2015-02-01

    If structures with complex shapes have space limitations, vibration tests using an exciter or impact hammer for the excitation are difficult. Although measuring the auto frequency response function at an unexcited point may not be practical via a vibration test, it can be obtained by assuming that the inertia acting on a dummy mass is an external force on the target structure upon exciting a different excitation point. We propose a method to estimate the auto frequency response functions at unexcited points by attaching a small mass (dummy mass), which is comparable to the accelerometer mass. The validity of the proposed method is demonstrated by comparing the auto frequency response functions estimated at unexcited points in a beam structure to those obtained from numerical simulations. We also consider random measurement errors by finite element analysis and vibration tests, but not bias errors. Additionally, the applicability of the proposed method is demonstrated by applying it to estimate the auto frequency response function of the lower arm in a car suspension.

  3. Sensitivity to Change and Responsiveness of Four Balance Measures for Community-Dwelling Older Adults

    PubMed Central

    Latham, Nancy K.; Jette, Alan M.; Wagenaar, Robert C.; Ni, Pengsheng; Slavin, Mary D.; Bean, Jonathan F.

    2012-01-01

    Background Impaired balance has a significant negative impact on mobility, functional independence, and fall risk in older adults. Although several, well-respected balance measures are currently in use, there is limited evidence regarding the most appropriate measure to assess change in community-dwelling older adults. Objective The aim of this study was to compare floor and ceiling effects, sensitivity to change, and responsiveness across the following balance measures in community-dwelling elderly people with functional limitations: Berg Balance Scale (BBS), Performance-Oriented Mobility Assessment total scale (POMA-T), POMA balance subscale (POMA-B), and Dynamic Gait Index (DGI). Design Retrospective data from a 16-week exercise trial were used. Secondary analyses were conducted on the total sample and by subgroups of baseline functional limitation or baseline balance scores. Methods Participants were 111 community-dwelling older adults 65 years of age or older, with functional limitations. Sensitivity to change was assessed using effect size, standardized response mean, and paired t tests. Responsiveness was assessed using minimally important difference (MID) estimates. Results No floor effects were noted. Ceiling effects were observed on all measures, including in people with moderate to severe functional limitations. The POMA-T, POMA-B, and DGI showed significantly larger ceiling effects compared with the BBS. All measures had low sensitivity to change in total sample analyses. Subgroup analyses revealed significantly better sensitivity to change in people with lower compared with higher baseline balance scores. Although both the total sample and lower baseline balance subgroups showed statistically significant improvement from baseline to 16 weeks on all measures, only the lower balance subgroup showed change scores that consistently exceeded corresponding MID estimates. Limitations This study was limited to comparing 4 measures of balance, and anchor-based methods for assessing MID could not be reported. Conclusions Important limitations, including ceiling effects and relatively low sensitivity to change and responsiveness, were noted across all balance measures, highlighting their limited utility across the full spectrum of the community-dwelling elderly population. New, more challenging measures are needed for better discrimination of balance ability in community-dwelling elderly people at higher functional levels. PMID:22114200

  4. Analyzing the Stability of Price Response Functions: Measuring the Influence of Different Parameters in a Monte Carlo Comparison

    NASA Astrophysics Data System (ADS)

    Brusch, Michael; Baier, Daniel

    The usage and the estimation of price response function is very important for strategic marketing decisions. Typically price response functions with an empirical basis are used. However, such price response functions are subject to a lot of disturbing influence factors, e.g., the assumed profit maximum price and the assumed corresponding quantity of sales. In such cases, the question how stable the found price response function is was not answered sufficiently up to now. In this paper, the question will be pursued how much (and what kind of) errors in market research are pardonable for a stable price response function. For the comparisons, a factorial design with synthetically generated and disturbed data is used.

  5. Validity and Responsiveness of the Two-Minute Walk Test for Measuring Functional Recovery After Total Knee Arthroplasty.

    PubMed

    Unnanuntana, Aasis; Ruangsomboon, Pakpoom; Keesukpunt, Worawut

    2018-06-01

    The 2-minute walk test (2mwt) is a performance-based test that evaluates functional recovery after total knee arthroplasty (TKA). This study evaluated its validity compared with the modified Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS), modified Knee Score, Numerical Pain Rating Scale, and Timed Up and Go test, and its responsiveness in assessing functional recovery in TKA patients. This prospective cohort study included 162 patients undergoing primary TKA between 2013 and 2015. We used patient-reported outcome measures (modified WOMAC, OKS, modified Knee Score, Numerical Pain Rating Scale) and performance-based tests (2mwt and Timed Up and Go test) at baseline and 3, 6, and 12 months postoperatively. The construct validity of 2mwt was determined between the 2mwt distances walked and other outcome measurements. To assess responsiveness, effect size and standardized response mean were analyzed. Minimal clinically important difference of 2mwt at 12 months after TKA was also calculated. All outcome measurements improved significantly from baseline to 3, 6, and 12 months postoperatively. Bivariate analysis revealed mild to moderate associations between the 2mwt and modified WOMAC function subscales, and moderate to strong associations with OKS. Mild to moderate correlations were found for pain and stiffness between 2mwt and other outcome measurements. The effect size and standardized response mean at 12 months were large, with a minimal clinically important difference of 12.7 m. 2mwt is a validated performance-based test with responsiveness properties. Being simple and easy to perform, it can be used routinely in clinical practice to evaluate functional recovery after TKA. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  6. Responsiveness of a Neuromuscular Recovery Scale for Spinal Cord Injury: Inpatient and Outpatient Rehabilitation

    DTIC Science & Technology

    2013-10-01

    Velozo’s research focus is on the development of functional outcome measures using Rasch measurement theory. Dr. Velozo’s research team has...functional outcome measures using Rasch measurement theory. Dr. Velozo’s research team has developed computerized adaptive measurement of physical

  7. Neutron spectroscopy with scintillation detectors using wavelets

    NASA Astrophysics Data System (ADS)

    Hartman, Jessica

    The purpose of this research was to study neutron spectroscopy using the EJ-299-33A plastic scintillator. This scintillator material provided a novel means of detection for fast neutrons, without the disadvantages of traditional liquid scintillation materials. EJ-299-33A provided a more durable option to these materials, making it less likely to be damaged during handling. Unlike liquid scintillators, this plastic scintillator was manufactured from a non-toxic material, making it safer to use, as well as easier to design detectors. The material was also manufactured with inherent pulse shape discrimination abilities, making it suitable for use in neutron detection. The neutron spectral unfolding technique was developed in two stages. Initial detector response function modeling was carried out through the use of the MCNPX Monte Carlo code. The response functions were developed for a monoenergetic neutron flux. Wavelets were then applied to smooth the response function. The spectral unfolding technique was applied through polynomial fitting and optimization techniques in MATLAB. Verification of the unfolding technique was carried out through the use of experimentally determined response functions. These were measured on the neutron source based on the Van de Graff accelerator at the University of Kentucky. This machine provided a range of monoenergetic neutron beams between 0.1 MeV and 24 MeV, making it possible to measure the set of response functions of the EJ-299-33A plastic scintillator detector to neutrons of specific energies. The response of a plutonium-beryllium (PuBe) source was measured using the source available at the University of Nevada, Las Vegas. The neutron spectrum reconstruction was carried out using the experimentally measured response functions. Experimental data was collected in the list mode of the waveform digitizer. Post processing of this data focused on the pulse shape discrimination analysis of the recorded response functions to remove the effects of photons and allow for source characterization based solely on the neutron response. The unfolding technique was performed through polynomial fitting and optimization techniques in MATLAB, and provided an energy spectrum for the PuBe source.

  8. Exploring the comparative responsiveness of a core set of outcome measures in a school-based conductive education programme.

    PubMed

    Wright, F V; Boschen, K; Jutai, J

    2005-05-01

    Conductive education (CE) is a holistic educational system that uses an active cognitive approach to teach individuals with motor disorders to become more functional participants in daily activities. While CE's popularity continues to grow in North America and Europe, its effectiveness has not been established. The lack of definition of responsive outcome measures for evaluation of CE programmes has limited the interpretability of conclusions from earlier studies evaluating effectiveness. To determine which measures from a core set were most responsive to physical, functional and psychosocial changes associated with a school-based CE programme. This was a one-group before and after data collection design using an 8-month follow-up period. We enrolled a referral sample of nine children with cerebral palsy in Kindergarten or Grade 1 (Gross Motor Function Classification System levels 3, 4 or 5). The study took place within a school-based CE programme at a Canadian children's rehabilitation centre. Children participated in a CE full-day class for an entire school year. Physical, functional, psychosocial and participation measures included: Gross Motor Function Measure (GMFM), Quality of Upper Extremity Skills Test (QUEST), Peabody Developmental Motor Scales, Paediatric Evaluation of Disability Inventory (PEDI), Pictorial Scale of Perceived Competence and Social Acceptance for Young Children, Individualized Educational Plan, and Goal Attainment Scaling (GAS). Four children from the study's second year were also evaluated on the Impact on Family Scale (IFS), GAS and School Function Assessment. The Gross Motor Function Measure, QUEST, PEDI (Caregiver Assistance) and IFS were most responsive to change. GAS was useful in documenting and quantifying goals. Problems were encountered in evaluating self-esteem and school participation. Several strong measures of outcome were identified. Further work is needed to find valid and sensitive psychosocial and school participation measures for these young children.

  9. Structural frequency functions for an impulsive, distributed forcing function

    NASA Technical Reports Server (NTRS)

    Bateman, Vesta I.

    1987-01-01

    The response of a penetrator structure to a spatially distributed mechanical impulse with a magnitude approaching field test force levels (1-2 Mlb) were measured. The frequency response function calculated from the response to this unique forcing function is compared to frequency response functions calculated from response to point forces of about 2000 pounds. The results show that the strain gages installed on the penetrator case respond similiarly to a point, axial force and to a spatially distributed, axial force. This result suggests that the distributed axial force generated in a penetration event may be reconstructed as a point axial force when the penetrator behaves in linear manner.

  10. Response function of modulated grid Faraday cup plasma instruments

    NASA Technical Reports Server (NTRS)

    Barnett, A.; Olbert, S.

    1986-01-01

    Modulated grid Faraday cup plasma analyzers are a very useful tool for making in situ measurements of space plasmas. One of their great attributes is that their simplicity permits their angular response function to be calculated theoretically. An expression is derived for this response function by computing the trajectories of the charged particles inside the cup. The Voyager plasma science experiment is used as a specific example. Two approximations to the rigorous response function useful for data analysis are discussed. Multisensor analysis of solar wind data indicates that the formulas represent the true cup response function for all angles of incidence with a maximum error of only a few percent.

  11. Development of the Parent Responses to School Functioning Questionnaire.

    PubMed

    Barber Garcia, Brittany N; Gray, Laura S; Simons, Laura E; Logan, Deirdre E

    2017-10-01

    Parents play an important role in supporting school functioning in youth with chronic pain, but no validated tools exists to assess parental responses to child and adolescent pain behaviors in the school context. Such a tool would be useful in identifying targets of change to reduce pain-related school impairment. The goal of this study was to develop and preliminarily validate the Parent Responses to School Functioning Questionnaire (PRSF), a parent self-report measure of this construct. After initial expert review and pilot testing, the measure was administered to 418 parents of children (ages 6-17 years) seen for initial multidisciplinary chronic pain clinic evaluation. The final 16-item PRSF showed evidence of good internal consistency (α = .82) and 2-week test-retest reliability (intraclass correlation coefficient = .87). Criterion validity was demonstrated by significant correlations with school absence rates and overall school functioning, and construct validity was demonstrated by correlations with general parental responses to pain. Three subscales emerged capturing parents' personal distress, parents' level of distrust of the school, and parents' expectations and behaviors related to their child's management of challenging school situations. These results provide preliminary support for the PRSF as a psychometrically sound tool to assess parents' responses to child pain in the school setting. The 16-item PRSF measures parental responses to their child's chronic pain in the school context. The clinically useful measure can inform interventions aimed reducing functional disability in children with chronic pain by enhancing parents' ability to respond adaptively to child pain behaviors. Copyright © 2017 American Pain Society. Published by Elsevier Inc. All rights reserved.

  12. A Response Function Approach for Rapid Far-Field Tsunami Forecasting

    NASA Astrophysics Data System (ADS)

    Tolkova, Elena; Nicolsky, Dmitry; Wang, Dailin

    2017-08-01

    Predicting tsunami impacts at remote coasts largely relies on tsunami en-route measurements in an open ocean. In this work, these measurements are used to generate instant tsunami predictions in deep water and near the coast. The predictions are generated as a response or a combination of responses to one or more tsunameters, with each response obtained as a convolution of real-time tsunameter measurements and a pre-computed pulse response function (PRF). Practical implementation of this method requires tables of PRFs in a 3D parameter space: earthquake location-tsunameter-forecasted site. Examples of hindcasting the 2010 Chilean and the 2011 Tohoku-Oki tsunamis along the US West Coast and beyond demonstrated high accuracy of the suggested technology in application to trans-Pacific seismically generated tsunamis.

  13. Reliability and responsiveness of the gross motor function measure-88 in children with cerebral palsy.

    PubMed

    Ko, Jooyeon; Kim, MinYoung

    2013-03-01

    The Gross Motor Function Measure (GMFM-88) is commonly used in the evaluation of gross motor function in children with cerebral palsy (CP). The relative reliability of GMFM-88 has been assessed in children with CP. However, little information is available regarding the absolute reliability or responsiveness of GMFM-88. The purpose of this study was to determine the absolute and relative reliability and the responsiveness of the GMFM-88 in evaluating gross motor function in children with CP. A clinical measurement design was used. Ten raters scored the GMFM-88 in 84 children (mean age=3.7 years, SD=1.9, range=10 months to 9 years 9 months) from video records across all Gross Motor Function Classification System (GMFCS) levels to establish interrater reliability. Two raters participated to assess intrarater reliability. Responsiveness was determined from 3 additional assessments after the baseline assessment. The interrater and intrarater intraclass correlation coefficients (ICCs) with 95% confidence intervals, standard error of measurement (SEM), smallest real difference (SRD), effect size (ES), and standardized response mean (SRM) were calculated. The relative reliability of the GMFM was excellent (ICCs=.952-1.000). The SEM and SRD for total score of the GMFM were acceptable (1.60 and 3.14, respectively). Additionally, the ES and SRM of the dimension goal scores increased gradually in the 3 follow-up assessments (GMFCS levels I and II: ES=0.5, 0.6, and 0.8 and SRM=1.3, 1.8, and 2.0; GMFCS levels III-V: ES=0.4, 0.7, and 0.9 and SRM=1.5, 1.7, and 2.0). Children over 10 years of age with CP were not included in this study, so the results should not be generalized to all children with CP. Both the reliability and the responsiveness of the GMFM-88 are reasonable for measuring gross motor function in children with CP.

  14. Cross-cultural adaptation, validation, and responsiveness of the Korean version of the AUSCAN Osteoarthritis Index.

    PubMed

    Moon, Ki Won; Lee, Shin-Seok; Kim, Jin Hyun; Song, Ran; Lee, Eun Young; Song, Yeong Wook; Bellamy, Nicholas; Lee, Eun Bong

    2012-11-01

    The Australian/Canadian Osteoarthritis Hand Index (AUSCAN) is a patient self-reported 15-item questionnaire measuring the severity of hand osteoarthritis symptoms in the respect of pain, stiffness, and function. In this study, we developed a Korean version of the AUSCAN Index (K-AUSCAN) and confirmed its reliability, validity, and responsiveness. The AUSCAN Index was translated into Korean by 3 translators and translated back into English by 3 different translators. In a group of 53 patients with clinical hand osteoarthritis (mean age 58.3 ± 7.6 years), validity was evaluated against other outcome measures, including the Functional Index for Hand Osteoarthritis (FIHOA) and Multidimensional Health Assessment Questionnaire (MDHAQ). Test-retest reliability was assessed at a 2-weeks interval in 51 patients. Internal consistency of K-AUSCAN was evaluated by Cronbach's α. Responsiveness was measured by standardized response mean (SRM). The test-retest reliability of K-AUSCAN yielded intraclass correlation coefficient of 0.46 for pain, 0.58 for stiffness, and 0.67 for function. The internal consistency of K-AUSCAN was satisfactory with Cronbach's α of 0.89 for pain and 0.93 for function. The K-AUSCAN index showed good correlation with other measures (r (2) was 0.67 for K-AUSCAN pain and MDHAQ pain; r (2) was 0.72 for K-AUSCAN function and FIHOA). The pain and function of K-AUSCAN correlated substantially with each other and moderately with stiffness subscale. The average SRM for K-AUSCAN pain, stiffness, and function was -0.92, -0.48, and -0.84, respectively. The Korean version of the AUSCAN Index is a valid, reliable, and responsive tool for the assessment of hand osteoarthritis symptoms.

  15. Measurement of absolute response functions and detection efficiencies of an NE213 scintillator up to 600 MeV

    NASA Astrophysics Data System (ADS)

    Kajimoto, Tsuyoshi; Shigyo, Nobuhiro; Sanami, Toshiya; Ishibashi, Kenji; Haight, Robert C.; Fotiades, Nikolaos

    2011-02-01

    Absolute neutron response functions and detection efficiencies of an NE213 liquid scintillator that was 12.7 cm in diameter and 12.7 cm in thickness were measured for neutron energies between 15 and 600 MeV at the Weapons Neutron Research facility of the Los Alamos Neutron Science Center. The experiment was performed with continuous-energy neutrons on a spallation neutron source by 800-MeV proton incidence. The incident neutron flux was measured using a 238U fission ionization chamber. Measured response functions and detection efficiencies were compared with corresponding calculations using the SCINFUL-QMD code. The calculated and experimental values were in good agreement for data below 70 MeV. However, there were discrepancies in the energy region between 70 and 150 MeV. Thus, the code was partly modified and the revised code provided better agreement with the experimental data.

  16. Social inclusion enhances biological motion processing: A functional near-infrared spectroscopy study

    PubMed Central

    Bolling, Danielle Z.; Pelphrey, Kevin A.; Kaiser, Martha D.

    2012-01-01

    Humans are especially tuned to the movements of other people. Neural correlates of this social attunement have been proposed to lie in and around the right posterior superior temporal sulcus (STS) region, which robustly responds to biological motion in contrast to a variety of non-biological motions. This response persists even when no form information is provided, as in point-light displays (PLDs). The aim of the current study was to assess the ability of functional near-infrared spectroscopy (fNIRS) to reliably measure brain responses to PLDs of biological motion, and determine the sensitivity of these responses to interpersonal contextual factors. To establish reliability, we measured brain activation to biological motion with fNIRS and functional magnetic resonance imaging (fMRI) during two separate sessions in an identical group of 12 participants. To establish sensitivity, brain responses to biological motion measured with fNIRS were subjected to an additional social manipulation where participants were either socially included or excluded before viewing PLDs of biological motion. Results revealed comparable brain responses to biological motion using fMRI and fNIRS in the right supramarginal gyrus. Further, social inclusion increased brain responses to biological motion in right supramarginal gyrus and posterior STS. Thus, fNIRS can reliably measure brain responses to biological motion and can detect social experience-dependent modulations of these brain responses. PMID:22941501

  17. The relationship between functional capacity and community responsibilities in middle-aged and older Latinos of Mexican origin with chronic psychosis.

    PubMed

    Cardenas, Veronica; Mausbach, Brent T; Barrio, Concepcion; Bucardo, Jesus; Jeste, Dilip; Patterson, Thomas

    2008-01-01

    The purpose of this study was to examine the relationship between scores on the UCSD Performance-based Skills Assessment (UPSA), a performance-based measure of functional capacity, and level of patient community responsibilities (i.e., work for pay; volunteer work; attend school; household duties) in a Latino sample. Participants were 58 middle-aged and older Latinos of Mexican origin (mean age=48.8 years) with a diagnosis of schizophrenia or schizoaffective disorder. We conducted an analysis of covariance (ANCOVA), controlling for age, symptoms of psychosis, and participant language, to determine if greater participation in community responsibilities was associated with higher functional capacity, as measured by the UPSA. Results indicated significant group differences in UPSA scores (F=5.11, df=2, 51; p=.009), with patients reporting only a single community responsibility having significantly higher UPSA scores than those reporting zero community responsibilities (p=.016) and those reporting two responsibilities scoring significantly higher than those reporting zero community responsibility (p=.008). There were no differences found between those reporting one and those reporting two community responsibilities (p=.256). In contrast, no group differences were observed on the Dementia Rating Scale, a global measure of cognitive functioning (F=2.14, df=2, 51; p=.128). These results provide initial support for the validity of the UPSA in Latino patients of Mexican origin, and suggest that improvement in functional capacity (i.e., UPSA scores) may be associated with increased capacity for greater community involvement in this population.

  18. The Relationship between Functional Capacity and Community Responsibilities in Middle-aged and Older Latinos of Mexican Origin with Chronic Psychosis

    PubMed Central

    Cardenas, Veronica; Mausbach, Brent T.; Barrio, Concepcion; Bucardo, Jesus; Jeste, Dilip; Patterson, Thomas

    2008-01-01

    The purpose of this study was to examine the relationship between scores on the UCSD Performance-based Skills Assessment (UPSA), a performance-based measure of functional capacity, and level of patient community responsibilities (i.e., work for pay; volunteer work; attend school; household duties) in a Latino sample. Participants were 58 middle-aged and older Latinos of Mexican origin (mean age = 48.8 years) with a diagnosis of schizophrenia or schizoaffective disorder. We conducted an analysis of covariance (ANCOVA), controlling for age, symptoms of psychosis, and participant language, to determine if greater participation in community responsibilities was associated with higher functional capacity, as measured by the UPSA. Results indicated significant group differences in UPSA scores (F = 5.11, df = 2,51; p = .009), with patients reporting only a single community responsibility having significantly higher UPSA scores than those reporting zero community responsibilities (p = .016) and those reporting two responsibilities scoring significantly higher than those reporting zero community responsibility (p = .008). There were no differences found between those reporting one and those reporting two community responsibilities (p= .256). In contrast, no group differences were observed on the Dementia Rating Scale, a global measure of cognitive functioning (F = 2.14, df = 2,51; p = .128). These results provide initial support for the validity of the UPSA in Latino patients of Mexican origin, and suggest that improvement in functional capacity (i.e., UPSA scores) may be associated with increased capacity for greater community involvement in this population. PMID:17936585

  19. Robustness of weighted networks

    NASA Astrophysics Data System (ADS)

    Bellingeri, Michele; Cassi, Davide

    2018-01-01

    Complex network response to node loss is a central question in different fields of network science because node failure can cause the fragmentation of the network, thus compromising the system functioning. Previous studies considered binary networks where the intensity (weight) of the links is not accounted for, i.e. a link is either present or absent. However, in real-world networks the weights of connections, and thus their importance for network functioning, can be widely different. Here, we analyzed the response of real-world and model networks to node loss accounting for link intensity and the weighted structure of the network. We used both classic binary node properties and network functioning measure, introduced a weighted rank for node importance (node strength), and used a measure for network functioning that accounts for the weight of the links (weighted efficiency). We find that: (i) the efficiency of the attack strategies changed using binary or weighted network functioning measures, both for real-world or model networks; (ii) in some cases, removing nodes according to weighted rank produced the highest damage when functioning was measured by the weighted efficiency; (iii) adopting weighted measure for the network damage changed the efficacy of the attack strategy with respect the binary analyses. Our results show that if the weighted structure of complex networks is not taken into account, this may produce misleading models to forecast the system response to node failure, i.e. consider binary links may not unveil the real damage induced in the system. Last, once weighted measures are introduced, in order to discover the best attack strategy, it is important to analyze the network response to node loss using nodes rank accounting the intensity of the links to the node.

  20. OZONE-INDUCED RESPIRATORY SYMPTOMS AND LUNG FUNCTION DECREMENTS IN HUMANS: EXPOSURE-RESPONSE MODELS

    EPA Science Inventory

    Short duration exposure to ozone (<8 hr) is known to result in lung function decrements and respiratory symptoms in humans. The magnitudes of these responses are functions of ozone concentration (C), activity level measured by minute ventilation (Ve), duration of exposure (T), a...

  1. Kinetic damping in the spectra of the spherical impedance probe

    NASA Astrophysics Data System (ADS)

    Oberrath, J.

    2018-04-01

    The impedance probe is a measurement device to measure plasma parameters, such as electron density. It consists of one electrode connected to a network analyzer via a coaxial cable and is immersed into a plasma. A bias potential superposed with an alternating potential is applied to the electrode and the response of the plasma is measured. Its dynamical interaction with the plasma in an electrostatic, kinetic description can be modeled in an abstract notation based on functional analytic methods. These methods provide the opportunity to derive a general solution, which is given as the response function of the probe–plasma system. It is defined by the matrix elements of the resolvent of an appropriate dynamical operator. Based on the general solution, a residual damping for vanishing pressure can be predicted and can only be explained by kinetic effects. In this paper, an explicit response function of the spherical impedance probe is derived. Therefore, the resolvent is determined by its algebraic representation based on an expansion in orthogonal basis functions. This allows one to compute an approximated response function and its corresponding spectra. These spectra show additional damping due to kinetic effects and are in good agreement with former kinetically determined spectra.

  2. Thirty Years of Nonparametric Item Response Theory.

    ERIC Educational Resources Information Center

    Molenaar, Ivo W.

    2001-01-01

    Discusses relationships between a mathematical measurement model and its real-world applications. Makes a distinction between large-scale data matrices commonly found in educational measurement and smaller matrices found in attitude and personality measurement. Also evaluates nonparametric methods for estimating item response functions and…

  3. Objective Measures of Visual Function in Papilledema

    PubMed Central

    Moss, Heather E.

    2016-01-01

    Synopsis Visual function is an important parameter to consider when managing patients with papilledema. Though the current standard of care uses standard automated perimetry (SAP) to obtain this information, this test is inherently subjective and prone to patient errors. Objective visual function tests including the visual evoked potential, pattern electroretinogram, photopic negative response of the full field electroretinogram, and pupillary light response have the potential to replace or supplement subjective visual function tests in papilledema management. This article reviews the evidence for use of objective visual function tests to assess visual function in papilledema and discusses future investigations needed to develop them as clinically practical and useful measures for this purpose. PMID:28451649

  4. Measurement of the Energy-Dependent Angular Response of the ARES Detector System and Application to Aerial Imaging

    NASA Astrophysics Data System (ADS)

    Joshi, Tenzing H. Y.; Quiter, Brian J.; Maltz, Jonathan S.; Bandstra, Mark S.; Haefner, Andrew; Eikmeier, Nicole; Wagner, Eric; Luke, Tanushree; Malchow, Russell; McCall, Karen

    2017-07-01

    The Airborne Radiological Enhanced-sensor System (ARES) includes a prototype helicopter-borne CsI(Na) detector array that has been developed as part of the DHS Domestic Nuclear Detection Office Advanced Technology Demonstration. The detector system geometry comprises two pairs of 23-detector arrays designed to function as active masks, providing additional angular resolution of measured gamma rays in the roll dimension. Experimental measurements, using five radioisotopes (137Cs, 60Co, 241Am, 131I, and 99mTc), were performed to map the detector response in both roll and pitch dimensions. This paper describes the acquisition and analysis of these characterization measurements, calculation of the angular response of the ARES system, and how this response function is used to improve aerial detection and localization of radiological and nuclear threat sources.

  5. Measured Polarized Spectral Responsivity of JPSS J1 VIIRS Using the NIST T-SIRCUS

    NASA Technical Reports Server (NTRS)

    McIntire, Jeff; Young, James B.; Moyer, David; Waluschka, Eugene; Xiong, Xiaoxiong

    2015-01-01

    Recent pre-launch measurements performed on the Joint Polar Satellite System (JPSS) J1 Visible Infrared Imaging Radiometer Suite (VIIRS) using the National Institute of Standards and Technology (NIST) Traveling Spectral Irradiance and Radiance Responsivity Calibrations Using Uniform Sources (T-SIRCUS) monochromatic source have provided wavelength dependent polarization sensitivity for select spectral bands and viewing conditions. Measurements were made at a number of input linear polarization states (twelve in total) and initially at thirteen wavelengths across the bandpass (later expanded to seventeen for some cases). Using the source radiance information collected by an external monitor, a spectral responsivity function was constructed for each input linear polarization state. Additionally, an unpolarized spectral responsivity function was derived from these polarized measurements. An investigation of how the centroid, bandwidth, and detector responsivity vary with polarization state was weighted by two model input spectra to simulate both ground measurements as well as expected on-orbit conditions. These measurements will enhance our understanding of VIIRS polarization sensitivity, improve the design for future flight models, and provide valuable data to enhance product quality in the post-launch phase.

  6. Reference values for developing responsive functional outcome measures across the lifespan.

    PubMed

    McKay, Marnee J; Baldwin, Jennifer N; Ferreira, Paulo; Simic, Milena; Vanicek, Natalie; Burns, Joshua

    2017-04-18

    To generate a reference dataset of commonly performed functional outcome measures in 1,000 children and adults and investigate the influence of demographic, anthropometric, strength, and flexibility characteristics. Twelve functional outcome measures were collected from 1,000 healthy individuals aged 3-101 years: 6-minute walk test, 30-second chair stand test, timed stairs test, long jump, vertical jump, choice stepping reaction time, balance (Star Excursion Balance Test, tandem stance eyes open and closed, single-leg stance eyes closed), and dexterity (9-hole peg test, Functional Dexterity Test). Correlation and multiple regression analyses were performed to identify factors independently associated with each measure. Age- and sex-stratified reference values for functional outcome measures were generated. Functional performance increased through childhood and adolescence, plateaued during adulthood, and declined in older adulthood. While balance did not differ between the sexes, male participants generally performed better at gross motor tasks while female participants performed better at dexterous tasks. Height was the most consistent correlate of functional performance in children, while lower limb muscle strength was a major determinant in adolescents and adults. In older adults, age, lower limb strength, and joint flexibility explained up to 63% of the variance in functional measures. These normative reference values provide a framework to accurately track functional decline associated with neuromuscular disorders and assist development and validation of responsive outcome measures for therapeutic trials. © 2017 American Academy of Neurology.

  7. Continual Response Measurement: Design and Validation.

    ERIC Educational Resources Information Center

    Baggaley, Jon

    1987-01-01

    Discusses reliability and validity of continual response measurement (CRM), a computer-based measurement technique, and its use in social science research. Highlights include the importance of criterion-referencing the data, guidelines for designing studies using CRM, examples typifying their deductive and inductive functions, and a discussion of…

  8. Validity, invariance and responsiveness of a self-report measure of functional limitations and disability in multiple sclerosis.

    PubMed

    Motl, Robert W; McAuley, Edward; Suh, Yoojin

    2010-01-01

    This study examined the structural and external aspects of score validity for the abbreviated Late Life-Function and Disability Inventory (LL-FDI) as well as its longitudinal measurement invariance and responsiveness in individuals with multiple sclerosis (MS). The sample included 292 individuals with MS who completed a battery of questionnaires on two occasions separated by 6 months. The battery included the abbreviated LL-FDI along with measures of mobility disability; neurological impairments; symptoms of fatigue, anxiety, depression and pain; health status; and quality of life. The data were analysed using Analysis of Moment Structures (AMOS) and Statistical Package for the Social Sciences (SPSS), versions 16.0. Confirmatory factor analysis supported the structural validity and longitudinal measurement invariance of the disability and functional limitations components of the abbreviated LL-FDI. MANOVA and bivariate correlations supported the external aspects of score validity based on differences in mean scores as a function of clinical MS course (relapsing vs. progressive) and level of mobility disability (mild vs. moderate mobility disability) and associations with measures of neurological impairments, symptoms, health status and QOL, respectively. ANOVA established the responsiveness (i.e., sensitivity for reflecting clinically important differences in health status across time) of the functional limitations and disability components of the abbreviated LL-FDI for detecting changes in mobility disability across 6-months. Such findings provide a new option for the measurement of functional limitations and disability using the abbreviated LL-FDI in persons with MS.

  9. Electrophysiological measurement of human auditory function

    NASA Technical Reports Server (NTRS)

    Galambos, R.

    1975-01-01

    Knowledge of the human auditory evoked response is reviewed, including methods of determining this response, the way particular changes in the stimulus are coupled to specific changes in the response, and how the state of mind of the listener will influence the response. Important practical applications of this basic knowledge are discussed. Measurement of the brainstem evoked response, for instance, can state unequivocally how well the peripheral auditory apparatus functions. It might then be developed into a useful hearing test, especially for infants and preverbal or nonverbal children. Clinical applications of measuring the brain waves evoked 100 msec and later after the auditory stimulus are undetermined. These waves are clearly related to brain events associated with cognitive processing of acoustic signals, since their properties depend upon where the listener directs his attention and whether how long he expects the signal.

  10. Woman and partner-perceived partner responses predict pain and sexual satisfaction in provoked vestibulodynia (PVD) couples.

    PubMed

    Rosen, Natalie O; Bergeron, Sophie; Leclerc, Bianca; Lambert, Bernard; Steben, Marc

    2010-11-01

    Provoked vestibulodynia (PVD) is a highly prevalent vulvovaginal pain condition that results in significant sexual dysfunction, psychological distress, and reduced quality of life. Although some intra-individual psychological factors have been associated with PVD, studies to date have neglected the interpersonal context of this condition. We examined whether partner responses to women's pain experience-from the perspective of both the woman and her partner-are associated with pain intensity, sexual function, and sexual satisfaction. One hundred ninety-one couples (M age for women=33.28, standard deviation [SD]=12.07, M age for men=35.79, SD=12.44) in which the woman suffered from PVD completed the spouse response scale of the Multidimensional Pain Inventory, assessing perceptions of partners' responses to the pain. Women with PVD also completed measures of pain, sexual function, sexual satisfaction, depression, and dyadic adjustment. Dependent measures were women's responses to: (i) a horizontal analog scale assessing the intensity of their pain during intercourse; (ii) the Female Sexual Function Index; and (iii) the Global Measure of Sexual Satisfaction Scale. Controlling for depression, higher solicitous partner responses were associated with higher levels of women's vulvovaginal pain intensity. This association was significant for partner-perceived responses (β=0.29, P<0.001) and for woman-perceived partner responses (β=0.16, P=0.04). After controlling for sexual function and dyadic adjustment, woman-perceived greater solicitous partner responses (β=0.16, P=0.02) predicted greater sexual satisfaction. Partner-perceived responses did not predict women's sexual satisfaction. Partner responses were not associated with women's sexual function. Findings support the integration of dyadic processes in the conceptualization and treatment of PVD by suggesting that partner responses to pain affect pain intensity and sexual satisfaction in affected women. © 2010 International Society for Sexual Medicine.

  11. Transient Receptor Potential Vanilloid 2 Regulates Myocardial Response to Exercise

    PubMed Central

    Naticchioni, Mindi; Karani, Rajiv; Smith, Margaret A.; Onusko, Evan; Robbins, Nathan; Jiang, Min; Radzyukevich, Tatiana; Fulford, Logan; Gao, Xu; Apel, Ryan; Heiny, Judith; Rubinstein, Jack; Koch, Sheryl E.

    2015-01-01

    The myocardial response to exercise is an adaptive mechanism that permits the heart to maintain cardiac output via improved cardiac function and development of hypertrophy. There are many overlapping mechanisms via which this occurs with calcium handling being a crucial component of this process. Our laboratory has previously found that the stretch sensitive TRPV2 channels are active regulators of calcium handling and cardiac function under baseline conditions based on our observations that TRPV2-KO mice have impaired cardiac function at baseline. The focus of this study was to determine the cardiac function of TRPV2-KO mice under exercise conditions. We measured skeletal muscle at baseline in WT and TRPV2-KO mice and subjected them to various exercise protocols and measured the cardiac response using echocardiography and molecular markers. Our results demonstrate that the TRPV2-KO mouse did not tolerate forced exercise although they became increasingly exercise tolerant with voluntary exercise. This occurs as the cardiac function deteriorates further with exercise. Thus, our conclusion is that TRPV2-KO mice have impaired cardiac functional response to exercise. PMID:26356305

  12. Direct measurement and calibration of the Kepler CCD Pixel Response Function for improved photometry and astrometry

    NASA Astrophysics Data System (ADS)

    Ninkov, Zoran

    Stellar images taken with telescopes and detectors in space are usually undersampled, and to correct for this, an accurate pixel response function is required. The standard approach for HST and KEPLER has been to measure the telescope PSF combined ("convolved") with the actual pixel response function, super-sampled by taking into account dithered or offset observed images of many stars (Lauer [1999]). This combined response function has been called the "PRF" (Bryson et al. [2011]). However, using such results has not allowed astrometry from KEPLER to reach its full potential (Monet et al. [2010], [2014]). Given the precision of KEPLER photometry, it should be feasible to use a pre-determined detector pixel response function (PRF) and an optical point spread function (PSF) as separable quantities to more accurately correct photometry and astrometry for undersampling. Wavelength (i.e. stellar color) and instrumental temperature should be affecting each of these differently. Discussion of the PRF in the "KEPLER Instrument Handbook" is limited to an ad-hoc extension of earlier measurements on a quite different CCD. It is known that the KEPLER PSF typically has a sharp spike in the middle, and the main bulk of the PSF is still small enough to be undersampled, so that any substructure in the pixel may interact significantly with the optical PSF. Both the PSF and PRF are probably asymmetric. We propose to measure the PRF for an example of the CCD sensors used on KEPLER at sufficient sampling resolution to allow significant improvement of KEPLER photometry and astrometry, in particular allowing PSF fitting techniques to be used on the data archive.

  13. Sensitive subgroups and normal variation in pulmonary function response to air pollution episodes.

    PubMed Central

    Brunekreef, B; Kinney, P L; Ware, J H; Dockery, D; Speizer, F E; Spengler, J D; Ferris, B G

    1991-01-01

    The Clean Air Act requires that sensitive subgroups of exposed populations be protected from adverse health effects of air pollution exposure. Hence, data suggesting the existence of sensitive subgroups can have an important impact on regulatory decisions. Some investigators have interpreted differences among individuals in observed pulmonary function response to air pollution episodes as evidence that individuals differ in their sensitivity. An alternative explanation is that the differences are due entirely to normal variation in repeated pulmonary function measurements. This paper investigates this question by reanalyzing data from three studies of children exposed to air pollution episodes to determine whether the observed variability in pulmonary function response indicates differences in sensitivity or natural interoccasion variability. One study investigated exposures to total suspended particulates (TSP), the other two investigated exposure to ozone. In all studies, each child's response to air pollution exposures was summarized by regressing that child's set of pulmonary function measurements on the air pollution concentrations on the day or days before measurement. The within-child and between-child variances of these slopes were used to test the hypothesis of variable sensitivity. Regression slopes did not vary significantly among children exposed to episodes of high TSP concentration, but there was evidence of heterogeneity in both studies of ozone exposures. The finding of heterogeneous response to ozone exposure is consistent with the epidemiologic and chamber studies of ozone exposures, but the lack of evidence for heterogeneous response to TSP exposures implies that observed variation in response can be explained by sampling variability rather than the presence of sensitive subgroup. PMID:2050060

  14. Assessment of the setup dependence of detector response functions for mega-voltage linear accelerators

    PubMed Central

    Fox, Christopher; Simon, Tom; Simon, Bill; Dempsey, James F.; Kahler, Darren; Palta, Jatinder R.; Liu, Chihray; Yan, Guanghua

    2010-01-01

    Purpose: Accurate modeling of beam profiles is important for precise treatment planning dosimetry. Calculated beam profiles need to precisely replicate profiles measured during machine commissioning. Finite detector size introduces perturbations into the measured profiles, which, in turn, impact the resulting modeled profiles. The authors investigate a method for extracting the unperturbed beam profiles from those measured during linear accelerator commissioning. Methods: In-plane and cross-plane data were collected for an Elekta Synergy linac at 6 MV using ionization chambers of volume 0.01, 0.04, 0.13, and 0.65 cm3 and a diode of surface area 0.64 mm2. The detectors were orientated with the stem perpendicular to the beam and pointing away from the gantry. Profiles were measured for a 10×10 cm2 field at depths ranging from 0.8 to 25.0 cm and SSDs from 90 to 110 cm. Shaping parameters of a Gaussian response function were obtained relative to the Edge detector. The Gaussian function was deconvolved from the measured ionization chamber data. The Edge detector profile was taken as an approximation to the true profile, to which deconvolved data were compared. Data were also collected with CC13 and Edge detectors for additional fields and energies on an Elekta Synergy, Varian Trilogy, and Siemens Oncor linear accelerator and response functions obtained. Response functions were compared as a function of depth, SSD, and detector scan direction. Variations in the shaping parameter were introduced and the effect on the resulting deconvolution profiles assessed. Results: Up to 10% setup dependence in the Gaussian shaping parameter occurred, for each detector for a particular plane. This translated to less than a ±0.7 mm variation in the 80%–20% penumbral width. For large volume ionization chambers such as the FC65 Farmer type, where the cavity length to diameter ratio is far from 1, the scan direction produced up to a 40% difference in the shaping parameter between in-plane and cross-plane measurements. This is primarily due to the directional difference in penumbral width measured by the FC65 chamber, which can more than double in profiles obtained with the detector stem parallel compared to perpendicular to the scan direction. For the more symmetric CC13 chamber the variation was only 3% between in-plane and cross-plane measurements. Conclusions: The authors have shown that the detector response varies with detector type, depth, SSD, and detector scan direction. In-plane vs cross-plane scanning can require calculation of a direction dependent response function. The effect of a 10% overall variation in the response function, for an ionization chamber, translates to a small deviation in the penumbra from that of the Edge detector measured profile when deconvolved. Due to the uncertainties introduced by deconvolution the Edge detector would be preferable in obtaining an approximation of the true profile, particularly for field sizes where the energy dependence of the diode can be neglected. However, an averaged response function could be utilized to provide a good approximation of the true profile for large ionization chambers and for larger fields for which diode detectors are not recommended. PMID:20229856

  15. Study on Response Function of Organic Liquid Scintillator for High-Energy Neutrons

    NASA Astrophysics Data System (ADS)

    Satoh, Daiki; Sato, Tatsuhiko; Endo, Akira; Yamaguchi, Yasuhiro; Takada, Masashi; Ishibashi, Kenji

    2005-05-01

    Response functions of liquid organic scintillator for neutrons up to 800 MeV have been measured at the Heavy-Ion Medical Accelerator in Chiba (HIMAC) of National Institute of Radiological Sciences (NIRS). 800-MeV/u Si ions and 400-MeV/u C ions bombarded a thick carbon target to produce neutrons. The kinetic energies of emitted neutrons were determined by the time-of-flight (TOF) method. Light output for neutrons was evaluated by eliminating events due to gamma-rays and charged particles. The measured response functions were compared with calculations using SCINFUL-QMD and CECIL codes. It was found that SCINFUL-QMD reproduced our experimental data adequately.

  16. Study on Response Function of Organic Liquid Scintillator for High-Energy Neutrons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Satoh, Daiki; Sato, Tatsuhiko; Endo, Akira

    2005-05-24

    Response functions of liquid organic scintillator for neutrons up to 800 MeV have been measured at the Heavy-Ion Medical Accelerator in Chiba (HIMAC) of National Institute of Radiological Sciences (NIRS). 800-MeV/u Si ions and 400-MeV/u C ions bombarded a thick carbon target to produce neutrons. The kinetic energies of emitted neutrons were determined by the time-of-flight (TOF) method. Light output for neutrons was evaluated by eliminating events due to gamma-rays and charged particles. The measured response functions were compared with calculations using SCINFUL-QMD and CECIL codes. It was found that SCINFUL-QMD reproduced our experimental data adequately.

  17. Does grip strength reflect isokinetic muscle strength in lower limbs in patients with chronic inflammatory demyelinating polyneuropathy?

    PubMed

    Knak, Kirsten L; Andersen, Linda K; Christiansen, Ingelise; Markvardsen, Lars K

    2018-03-30

    Grip strength (GS) is a common measure of general muscle strength in patients with chronic inflammatory demyelinating polyneuropathy (CIDP). However, it is important to investigate the correlation and responsiveness of GS compared with isokinetic muscle strength (IKS) and function of the lower limbs. Seventy patients with CIDP were evaluated with GS, IKS, and functional measures of the lower limbs. Reevaluation was performed after 2 and 10/12 weeks. Correlation and response analyses were performed. GS correlated with IKS at the ankle (IKS ankle ; maximum Spearman's rank-order correlation [R S ] = 0.58) and with walking performance (maximum R S  = -0.38). IKS ankle was more responsive to detect change (standardized response mean [SRM] = 0.57) than GS (SRM = 0.27). GS does not seem to be an appropriate surrogate measure of IKS and function of the lower limbs in patients with CIDP. Muscle Nerve, 2018. © 2018 Wiley Periodicals, Inc.

  18. The response function of modulated grid Faraday cup plasma instruments

    NASA Technical Reports Server (NTRS)

    Barnett, A.; Olbert, S.

    1986-01-01

    Modulated grid Faraday cup plasma analyzers are a very useful tool for making in situ measurements of space plasmas. One of their great attributes is that their simplicity permits their angular response function to be calculated theoretically. An expression is derived for this response function by computing the trajectories of the charged particles inside the cup. The Voyager Plasma Science (PLS) experiment is used as a specific example. Two approximations to the rigorous response function useful for data analysis are discussed. The theoretical formulas were tested by multi-sensor analysis of solar wind data. The tests indicate that the formulas represent the true cup response function for all angles of incidence with a maximum error of only a few percent.

  19. Effect Size Measures for Differential Item Functioning in a Multidimensional IRT Model

    ERIC Educational Resources Information Center

    Suh, Youngsuk

    2016-01-01

    This study adapted an effect size measure used for studying differential item functioning (DIF) in unidimensional tests and extended the measure to multidimensional tests. Two effect size measures were considered in a multidimensional item response theory model: signed weighted P-difference and unsigned weighted P-difference. The performance of…

  20. Exploring the Relationship between Physiological Measures of Cochlear and Brainstem Function

    PubMed Central

    Dhar, S.; Abel, R.; Hornickel, J.; Nicol, T.; Skoe, E.; Zhao, W.; Kraus, N.

    2009-01-01

    Objective Otoacoustic emissions and the speech-evoked auditory brainstem response are objective indices of peripheral auditory physiology and are used clinically for assessing hearing function. While each measure has been extensively explored, their interdependence and the relationships between them remain relatively unexplored. Methods Distortion product otoacoustic emissions (DPOAE) and speech-evoked auditory brainstem responses (sABR) were recorded from 28 normal-hearing adults. Through correlational analyses, DPOAE characteristics were compared to measures of sABR timing and frequency encoding. Data were organized into two DPOAE (Strength and Structure) and five brainstem (Onset, Spectrotemporal, Harmonics, Envelope Boundary, Pitch) composite measures. Results DPOAE Strength shows significant relationships with sABR Spectrotemporal and Harmonics measures. DPOAE Structure shows significant relationships with sABR Envelope Boundary. Neither DPOAE Strength nor Structure is related to sABR Pitch. Conclusions The results of the present study show that certain aspects of the speech-evoked auditory brainstem responses are related to, or covary with, cochlear function as measured by distortion product otoacoustic emissions. Significance These results form a foundation for future work in clinical populations. Analyzing cochlear and brainstem function in parallel in different clinical populations will provide a more sensitive clinical battery for identifying the locus of different disorders (e.g., language based learning impairments, hearing impairment). PMID:19346159

  1. Functional Status Score for the Intensive Care Unit (FSS-ICU): An International Clinimetric Analysis of Validity, Responsiveness, and Minimal Important Difference

    PubMed Central

    Huang, Minxuan; Chan, Kitty S.; Zanni, Jennifer M.; Parry, Selina M.; Neto, Saint-Clair G. B.; Neto, Jose A. A.; da Silva, Vinicius Z. M.; Kho, Michelle E.; Needham, Dale M.

    2017-01-01

    Objective To evaluate the internal consistency, validity, responsiveness, and minimal important difference of the Functional Status Score for the Intensive Care Unit (FSS-ICU), a physical function measure designed for the intensive care unit (ICU). Design Clinimetric analysis. Settings Five international data sets from the United States, Australia, and Brazil. Patients 819 ICU patients. Intervention None. Measurements and Main Results Clinimetric analyses were initially conducted separately for each data source and time point to examine generalizability of findings, with pooled analyses performed thereafter to increase power of analyses. The FSS-ICU demonstrated good to excellent internal consistency. There was good convergent and discriminant validity, with significant and positive correlations (r = 0.30 to 0.95) between FSS-ICU and other physical function measures, and generally weaker correlations with non-physical measures (|r| = 0.01 to 0.70). Known group validity was demonstrated by significantly higher FSS-ICU scores among patients without ICU-acquired weakness (Medical Research Council sumscore ≥48 versus <48) and with hospital discharge to home (versus healthcare facility). FSS-ICU at ICU discharge predicted post-ICU hospital length of stay and discharge location. Responsiveness was supported via increased FSS-ICU scores with improvements in muscle strength. Distribution-based methods indicated a minimal important difference of 2.0 to 5.0. Conclusions The FSS-ICU has good internal consistency and is a valid and responsive measure of physical function for ICU patients. The estimated minimal important difference can be used in sample size calculations and in interpreting studies comparing the physical function of groups of ICU patients. PMID:27488220

  2. Executive functioning, emotion regulation, eating self-regulation, and weight status in low-income preschool children: How do they relate?

    PubMed Central

    Hughes, Sheryl O.; Power, Thomas G.; O’Connor, Teresia M.; Fisher, Jennifer Orlet

    2016-01-01

    The purpose of the present study was to examine relationships between child eating self-regulation, child non-eating self-regulation, and child BMIz in a low-income sample of Hispanic families with preschoolers. The eating in the absence of hunger task as well as parent-report of child satiety responsiveness and food responsiveness were used to assess child eating self-regulation. Two laboratory tasks assessing executive functioning, a parent questionnaire assessing child effortful control (a temperament dimension related to executive functioning), and the delay of gratification and gift delay tasks assessing child emotion regulation were used to assess child non-eating self-regulation. Bivariate correlations were run among all variables in the study. Hierarchical linear regression analyses assessed: 1) child eating self-regulation associations with the demographic, executive functioning, effortful control, and emotion regulation measures; and 2) child BMI z-scores associations with executive functioning, effortful control, emotion regulation measures, and eating self-regulation measures. Within child eating self-regulation, only the two parent-report measures were related. Low to moderate positive correlations were found between measures of executive functioning, effortful control, and emotion regulation. Only three relationships were found between child eating self-regulation and other forms of child self-regulation: eating in the absence of hunger was positively associated with delay of gratification, and poor regulation on the gift delay task was associated positively with maternal reports of food responsiveness and negatively with parent-reports of satiety responsiveness. Regression analyses showed that child eating self-regulation was associated with child BMIz but other forms of child self-regulation were not. Implications for understanding the role of self-regulation in the development of child obesity are discussed. PMID:25596501

  3. Executive functioning, emotion regulation, eating self-regulation, and weight status in low-income preschool children: how do they relate?

    PubMed

    Hughes, Sheryl O; Power, Thomas G; O'Connor, Teresia M; Orlet Fisher, Jennifer

    2015-06-01

    The purpose of the present study was to examine relationships between child eating self-regulation, child non-eating self-regulation, and child BMIz in a low-income sample of Hispanic families with preschoolers. The eating in the absence of hunger task as well as parent-report of child satiety responsiveness and food responsiveness were used to assess child eating self-regulation. Two laboratory tasks assessing executive functioning, a parent questionnaire assessing child effortful control (a temperament dimension related to executive functioning), and the delay of gratification and gift delay tasks assessing child emotion regulation were used to assess child non-eating self-regulation. Bivariate correlations were run among all variables in the study. Hierarchical linear regression analyses assessed: (1) child eating self-regulation associations with the demographic, executive functioning, effortful control, and emotion regulation measures; and (2) child BMI z-score associations with executive functioning, effortful control, emotion regulation measures, and eating self-regulation measures. Within child eating self-regulation, only the two parent-report measures were related. Low to moderate positive correlations were found between measures of executive functioning, effortful control, and emotion regulation. Only three relationships were found between child eating self-regulation and other forms of child self-regulation: eating in the absence of hunger was positively associated with delay of gratification, and poor regulation on the gift delay task was associated positively with maternal reports of food responsiveness and negatively with parent-reports of satiety responsiveness. Regression analyses showed that child eating self-regulation was associated with child BMIz but other forms of child self-regulation were not. Implications for understanding the role of self-regulation in the development of child obesity are discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Functional Groups Based on Leaf Physiology: Are they Spatially and Temporally Robust?

    NASA Technical Reports Server (NTRS)

    Foster, Tammy E.; Brooks, J. Renee; Quincy, Charles (Technical Monitor)

    2002-01-01

    The functional grouping hypothesis, which suggests that complexity in function can be simplified by grouping species with similar responses, was tested in the Florida scrub habitat. Functional groups were identified based on how species in fire maintained FL scrub function in terms of carbon, water and nitrogen dynamics. The suite of physiologic parameters measured to determine function included both instantaneous gas exchange measurements obtained from photosynthetic light response curves and integrated measures of function. Using cluster analysis, five distinct physiologically-based functional groups were identified. Using non-parametric multivariate analyses, it was determined that these five groupings were not altered by plot differences or by the three different management regimes; prescribed burn, mechanically treated and burn, and fire-suppressed. The physiological groupings also remained robust between the two years 1999 and 2000. In order for these groupings to be of use for scaling ecosystem processes, there needs to be an easy-to-measure morphological indicator of function. Life form classifications were able to depict the physiological groupings more adequately than either specific leaf area or leaf thickness. THe ability of life forms to depict the groupings was improved by separating the parasitic Ximenia americana from the shrub category.

  5. Cortical substrates and functional correlates of auditory deviance processing deficits in schizophrenia

    PubMed Central

    Rissling, Anthony J.; Miyakoshi, Makoto; Sugar, Catherine A.; Braff, David L.; Makeig, Scott; Light, Gregory A.

    2014-01-01

    Although sensory processing abnormalities contribute to widespread cognitive and psychosocial impairments in schizophrenia (SZ) patients, scalp-channel measures of averaged event-related potentials (ERPs) mix contributions from distinct cortical source-area generators, diluting the functional relevance of channel-based ERP measures. SZ patients (n = 42) and non-psychiatric comparison subjects (n = 47) participated in a passive auditory duration oddball paradigm, eliciting a triphasic (Deviant−Standard) tone ERP difference complex, here termed the auditory deviance response (ADR), comprised of a mid-frontal mismatch negativity (MMN), P3a positivity, and re-orienting negativity (RON) peak sequence. To identify its cortical sources and to assess possible relationships between their response contributions and clinical SZ measures, we applied independent component analysis to the continuous 68-channel EEG data and clustered the resulting independent components (ICs) across subjects on spectral, ERP, and topographic similarities. Six IC clusters centered in right superior temporal, right inferior frontal, ventral mid-cingulate, anterior cingulate, medial orbitofrontal, and dorsal mid-cingulate cortex each made triphasic response contributions. Although correlations between measures of SZ clinical, cognitive, and psychosocial functioning and standard (Fz) scalp-channel ADR peak measures were weak or absent, for at least four IC clusters one or more significant correlations emerged. In particular, differences in MMN peak amplitude in the right superior temporal IC cluster accounted for 48% of the variance in SZ-subject performance on tasks necessary for real-world functioning and medial orbitofrontal cluster P3a amplitude accounted for 40%/54% of SZ-subject variance in positive/negative symptoms. Thus, source-resolved auditory deviance response measures including MMN may be highly sensitive to SZ clinical, cognitive, and functional characteristics. PMID:25379456

  6. The relation between auditory-nerve temporal responses and perceptual rate integration in cochlear implants

    PubMed Central

    Hughes, Michelle L.; Baudhuin, Jacquelyn L.; Goehring, Jenny L.

    2014-01-01

    The purpose of this study was to examine auditory-nerve temporal response properties and their relation to psychophysical threshold for electrical pulse trains of varying rates (“rate integration”). The primary hypothesis was that better rate integration (steeper slope) would be correlated with smaller decrements in ECAP amplitude as a function of stimulation rate (shallower slope of the amplitude-rate function), reflecting a larger percentage of the neural population contributing more synchronously to each pulse in the train. Data were obtained for 26 ears in 23 cochlear-implant recipients. Electrically evoked compound action potential (ECAP) amplitudes were measured in response to each of 21 pulses in a pulse train for the following rates: 900, 1200, 1800, 2400, and 3500 pps. Psychophysical thresholds were obtained using a 3-interval, forced-choice adaptive procedure for 300-ms pulse trains of the same rates as used for the ECAP measures, which formed the rate-integration function. For each electrode, the slope of the psychophysical rate-integration function was compared to the following ECAP measures: (1) slope of the function comparing average normalized ECAP amplitude across pulses versus stimulation rate (“adaptation”), (2) the rate that produced the maximum alternation depth across the pulse train, and (3) rate at which the alternating pattern ceased (stochastic rate). Results showed no significant relations between the slope of the rate-integration function and any of the ECAP measures when data were collapsed across subjects. However, group data showed that both threshold and average ECAP amplitude decreased with increased stimulus rate, and within-subject analyses showed significant positive correlations between psychophysical thresholds and mean ECAP response amplitudes across the pulse train. These data suggest that ECAP temporal response patterns are complex and further study is required to better understand the relative contributions of adaptation, desynchronization, and firing probabilities of individual neurons that contribute to the aggregate ECAP response. PMID:25093283

  7. Neurovascular coupling in normal aging: a combined optical, ERP and fMRI study.

    PubMed

    Fabiani, Monica; Gordon, Brian A; Maclin, Edward L; Pearson, Melanie A; Brumback-Peltz, Carrie R; Low, Kathy A; McAuley, Edward; Sutton, Bradley P; Kramer, Arthur F; Gratton, Gabriele

    2014-01-15

    Brain aging is characterized by changes in both hemodynamic and neuronal responses, which may be influenced by the cardiorespiratory fitness of the individual. To investigate the relationship between neuronal and hemodynamic changes, we studied the brain activity elicited by visual stimulation (checkerboard reversals at different frequencies) in younger adults and in older adults varying in physical fitness. Four functional brain measures were used to compare neuronal and hemodynamic responses obtained from BA17: two reflecting neuronal activity (the event-related optical signal, EROS, and the C1 response of the ERP), and two reflecting functional hemodynamic changes (functional magnetic resonance imaging, fMRI, and near-infrared spectroscopy, NIRS). The results indicated that both younger and older adults exhibited a quadratic relationship between neuronal and hemodynamic effects, with reduced increases of the hemodynamic response at high levels of neuronal activity. Although older adults showed reduced activation, similar neurovascular coupling functions were observed in the two age groups when fMRI and deoxy-hemoglobin measures were used. However, the coupling between oxy- and deoxy-hemoglobin changes decreased with age and increased with increasing fitness. These data indicate that departures from linearity in neurovascular coupling may be present when using hemodynamic measures to study neuronal function. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Effects of acute exercise on attenuated vagal baroreflex function during bed rest

    NASA Technical Reports Server (NTRS)

    Convertino, Victor A.; Doerr, Donald F.; Guell, Antonio; Marini, J.-F.

    1992-01-01

    We measured carotid baroreceptor-cardiac reflex responses in six healthy men, 24 h before and 24 h after a bout of leg exercise during 6 deg head-down bed rest to determine if depressed vagal baroreflex function associated with exposure to microgravity environments could be reversed by a single exposure to acute intense exercise. Baroreflex responses were measured before bed rest and on day 7 of bed rest. An exercise bout consisting of dynamic and isometric actions of the quadriceps at graded speeds and resistances was performed on day 8 of bed rest and measurements of baroreflex response were repeated 24 h later. Vagally-mediated cardiac responses were provoked with ramped neck pressure-suction sequences comprising pressure elevations to +40 mm Hg, followed by serial, R-wave triggered 15 mm Hg reductions, to -65 mm Hg. Baroreceptor stimulus-cardiac response relationships were derived by plotting each R-R interval as a function of systolic pressure less the neck chamber pressure applied during the interval. Compared with pre-bed rest baseline measurements, 7 d of bed rest decreased the gain (maximum slope) of the baroreflex stimulus-response relationship by 16.8 +/- 3.4 percent (p less than 0.05). On day 9 of bed rest, 24 h after exercise, the maximum slope of the baroreflex stimulus-response relationship was increased (p less than 0.05) by 10.7 +/- 3.7 percent above pre-bed rest levels and 34.3 +/- 7.9 percent above bed rest day 7. Our data verify that vagally-mediated baroreflex function is depressed by exposure to simulated microgravity and demonstrate that this effect can be acutely reversed by exposure to a single bout of intense exercise.

  9. Schottky Noise and Beam Transfer Functions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blaskiewicz, M.

    2016-12-01

    Beam transfer functions (BTF)s encapsulate the stability properties of charged particle beams. In general one excites the beam with a sinusoidal signal and measures the amplitude and phase of the beam response. Most systems are very nearly linear and one can use various Fourier techniques to reduce the number of measurements and/or simulations needed to fully characterize the response. Schottky noise is associated with the finite number of particles in the beam. This signal is always present. Since the Schottky current drives wakefields, the measured Schottky signal is influenced by parasitic impedances.

  10. Uncertainty analysis of signal deconvolution using a measured instrument response function

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hartouni, E. P.; Beeman, B.; Caggiano, J. A.

    2016-10-05

    A common analysis procedure minimizes the ln-likelihood that a set of experimental observables matches a parameterized model of the observation. The model includes a description of the underlying physical process as well as the instrument response function (IRF). Here, we investigate the National Ignition Facility (NIF) neutron time-of-flight (nTOF) spectrometers, the IRF is constructed from measurements and models. IRF measurements have a finite precision that can make significant contributions to the uncertainty estimate of the physical model’s parameters. Finally, we apply a Bayesian analysis to properly account for IRF uncertainties in calculating the ln-likelihood function used to find the optimummore » physical parameters.« less

  11. Calibration of high-dynamic-range, finite-resolution x-ray pulse-height spectrometers for extracting electron energy distribution data from the PFRC-2 device

    NASA Astrophysics Data System (ADS)

    Swanson, C.; Jandovitz, P.; Cohen, S. A.

    2017-10-01

    Knowledge of the full x-ray energy distribution function (XEDF) emitted from a plasma over a large dynamic range of energies can yield valuable insights about the electron energy distribution function (EEDF) of that plasma and the dynamic processes that create them. X-ray pulse height detectors such as Amptek's X-123 Fast SDD with Silicon Nitride window can detect x-rays in the range of 200eV to 100s of keV. However, extracting EEDF from this measurement requires precise knowledge of the detector's response function. This response function, including the energy scale calibration, the window transmission function, and the resolution function, can be measured directly. We describe measurements of this function from x-rays from a mono-energetic electron beam in a purpose-built gas-target x-ray tube. Large-Z effects such as line radiation, nuclear charge screening, and polarizational Bremsstrahlung are discussed.

  12. Direct measurement of the effective infrared dielectric response of a highly doped semiconductor metamaterial.

    PubMed

    Al Mohtar, Abeer; Kazan, Michel; Taliercio, Thierry; Cerutti, Laurent; Blaize, Sylvain; Bruyant, Aurélien

    2017-03-24

    We have investigated the effective dielectric response of a subwavelength grating made of highly doped semiconductors (HDS) excited in reflection, using numerical simulations and spectroscopic measurement. The studied system can exhibit strong localized surface resonances and has, therefore, a great potential for surface-enhanced infrared absorption (SEIRA) spectroscopy application. It consists of a highly doped InAsSb grating deposited on lattice-matched GaSb. The numerical analysis demonstrated that the resonance frequencies can be inferred from the dielectric function of an equivalent homogeneous slab by accounting for the complex reflectivity of the composite layer. Fourier transform infrared reflectivity (FTIR) measurements, analyzed with the Kramers-Kronig conversion technique, were used to deduce the effective response in reflection of the investigated system. From the knowledge of this phenomenological dielectric function, transversal and longitudinal energy-loss functions were extracted and attributed to transverse and longitudinal resonance modes frequencies.

  13. Intestinal current measurement versus nasal potential difference measurements for diagnosis of cystic fibrosis: a case-control study.

    PubMed

    Bagheri-Hanson, Azadeh; Nedwed, Sebastian; Rueckes-Nilges, Claudia; Naehrlich, Lutz

    2014-10-04

    Nasal potential difference (NPD) and intestinal current measurement (ICM) are functional CFTR tests that are used as adjunctive diagnostic tools for cystic fibrosis (CF). Smoking has a systemic negative impact on CFTR function. A diagnostic comparison between NPD and ICM and the impact of smoking on both CFTR tests has not been done. The sweat chloride test, NPD, and ICM were performed in 18 patients with CF (sweat chloride >60 mmol/l), including 6 pancreatic sufficient (PS) patients, and 13 healthy controls, including 8 smokers. The NPD CFTR response to Cl-free and isoproterenol perfusion (Δ0Cl- + Iso) was compared to the ICM CFTR response to forskolin/IBMX, carbachol, and histamine (ΔIsc, forskolin/IBMX+ carbachol+histamine). The mean NPD CFTR response and ICM CFTR response between patients with CF and healthy controls was significantly different (p <0.001), but not between patients with CF who were PS and those who were pancreatic insufficient (PI). Smokers have a decreased CFTR response measured by NPD (p = 0.049). For ICM there is a trend towards decreased CFTR response (NS). Three healthy control smokers had NPD responses within the CF-range. In contrast to NPD, there was no overlap of the ICM response between patients with CF and controls. ICM is superior to NPD in distinguishing between patients with CF who have a sweat chloride > 60 mmol/l and healthy controls, including smokers. Neither NPD nor ICM differentiated between patients with CF who were PS from those who were PI. Smoking has a negative impact on CFTR function in healthy controls measured by NPD and challenges the diagnostic interpretation of NPD, but not ICM.

  14. Outcome measurement of hand function following mirror therapy for stroke rehabilitation: A systematic review.

    PubMed

    Cantero-Téllez, Raquel; Naughton, Nancy; Algar, Lori; Valdes, Kristin

    2018-02-28

    Systematic review. Mirror therapy is a treatment used to address hand function following a stroke. Measurement of outcomes using appropriate assessment tools is crucial; however, many assessment options exist. The purpose of this study is to systematically review outcome measures that are used to assess hand function following mirror therapy after stroke and, in addition, to identify the psychometric and descriptive properties of the included measures and through the linking process determine if the outcome measures are representative of the International Classification of Functioning, Disability and Health (ICF). Following a comprehensive literature search, outcome measures used in the included studies were linked to the ICF and analyzed based on descriptive information and psychometric properties. Eleven studies met inclusion criteria and included 24 different assessment tools to measure hand or upper limb function. Most outcome measures used in the selected studies (63%) were rated by the evaluating therapist. Thirteen outcome measures (54%) linked to the ICF body function category and 10 measures (42%) linked to activities and participation. One outcome measure was linked to not defined, and all other ICF categories were not represented. A majority of outcome measures have been assessed for validity, reliability, and responsiveness, but responsiveness was the least investigated psychometric property. Current studies on mirror therapy after stroke are not consistent in the assessment tools used to determine hand function. Understanding of study outcomes requires analysis of the assessment tools. The outcome measures used in the included studies are not representative of personal and environmental factors, but tools linking to body functions and activities and participations provide important information on functional outcome. Integrating a combination of measures that are psychometrically sound and reflective of the ICF should be considered for assessment of hand function after mirror therapy after stroke. Copyright © 2018 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  15. Parent Prediction of Child Mood and Emotional Resilience: The Role of Parental Responsiveness and Psychological Control

    PubMed Central

    Boughton, Kristy L.; Lumley, Margaret N.

    2011-01-01

    Research consistently shows low to moderate agreement between parent and child reports of child mood, suggesting that parents are not always the best predictors of child emotional functioning. This study examines parental responsiveness and psychological control for improving prediction of early adolescent mood and emotional resilience beyond parent report of child emotional functioning. Participants were 268 early adolescents administered measures of depression symptoms, emotional resilience, and perceptions of parenting. Parents of participating youth completed measures of youth emotional functioning. Parental responsiveness and psychological control each emerged as family variables that may be of value for predicting child emotional functioning beyond parent reports. Specifically, responsiveness explained significant variance in child depression and resilience after accounting for parent reports, while parental psychological control increased prediction of child mood alone. Results generally suggest that parenting behaviours may be an important consideration when children and parents provide discrepant reports of child emotional well-being. Conceptual and clinical implications of these results are discussed. PMID:22110912

  16. Dopamine Reward Prediction Error Responses Reflect Marginal Utility

    PubMed Central

    Stauffer, William R.; Lak, Armin; Schultz, Wolfram

    2014-01-01

    Summary Background Optimal choices require an accurate neuronal representation of economic value. In economics, utility functions are mathematical representations of subjective value that can be constructed from choices under risk. Utility usually exhibits a nonlinear relationship to physical reward value that corresponds to risk attitudes and reflects the increasing or decreasing marginal utility obtained with each additional unit of reward. Accordingly, neuronal reward responses coding utility should robustly reflect this nonlinearity. Results In two monkeys, we measured utility as a function of physical reward value from meaningful choices under risk (that adhered to first- and second-order stochastic dominance). The resulting nonlinear utility functions predicted the certainty equivalents for new gambles, indicating that the functions’ shapes were meaningful. The monkeys were risk seeking (convex utility function) for low reward and risk avoiding (concave utility function) with higher amounts. Critically, the dopamine prediction error responses at the time of reward itself reflected the nonlinear utility functions measured at the time of choices. In particular, the reward response magnitude depended on the first derivative of the utility function and thus reflected the marginal utility. Furthermore, dopamine responses recorded outside of the task reflected the marginal utility of unpredicted reward. Accordingly, these responses were sufficient to train reinforcement learning models to predict the behaviorally defined expected utility of gambles. Conclusions These data suggest a neuronal manifestation of marginal utility in dopamine neurons and indicate a common neuronal basis for fundamental explanatory constructs in animal learning theory (prediction error) and economic decision theory (marginal utility). PMID:25283778

  17. Linearization of Positional Response Curve of a Fiber-optic Displacement Sensor

    NASA Astrophysics Data System (ADS)

    Babaev, O. G.; Matyunin, S. A.; Paranin, V. D.

    2018-01-01

    Currently, the creation of optical measuring instruments and sensors for measuring linear displacement is one of the most relevant problems in the area of instrumentation. Fiber-optic contactless sensors based on the magneto-optical effect are of special interest. They are essentially contactless, non-electrical and have a closed optical channel not subject to contamination. The main problem of this type of sensors is the non-linearity of their positional response curve due to the hyperbolic nature of the magnetic field intensity variation induced by moving the magnetic source mounted on the controlled object relative to the sensing element. This paper discusses an algorithmic method of linearizing the positional response curve of fiber-optic displacement sensors in any selected range of the displacements to be measured. The method is divided into two stages: 1 - definition of the calibration function, 2 - measurement and linearization of the positional response curve (including its temperature stabilization). The algorithm under consideration significantly reduces the number of points of the calibration function, which is essential for the calibration of temperature dependence, due to the use of the points that randomly deviate from the grid points with uniform spacing. Subsequent interpolation of the deviating points and piecewise linear-plane approximation of the calibration function reduces the microcontroller storage capacity for storing the calibration function and the time required to process the measurement results. The paper also presents experimental results of testing real samples of fiber-optic displacement sensors.

  18. Person Response Functions and the Definition of Units in the Social Sciences

    ERIC Educational Resources Information Center

    Engelhard, George, Jr.; Perkins, Aminah F.

    2011-01-01

    Humphry (this issue) has written a thought-provoking piece on the interpretation of item discrimination parameters as scale units in item response theory. One of the key features of his work is the description of an item response theory (IRT) model that he calls the logistic measurement function that combines aspects of two traditions in IRT that…

  19. Water immersion decreases sympathetic skin response during color–word Stroop test

    PubMed Central

    Yamazaki, Yudai; Takahashi, Akari; Uetake, Yoshihito; Nakano, Saki; Iguchi, Kaho; Baba, Yasuhiro; Nara, Rio; Shimoyama, Yoshimitsu

    2017-01-01

    Water immersion alters the autonomic nervous system (ANS) response in humans. The effect of water immersion on executive function and ANS responses related to executive function tasks was unknown. Therefore, this study aimed to determine whether water immersion alters ANS response during executive tasks. Fourteen healthy participants performed color–word-matching Stroop tasks before and after non-immersion and water immersion intervention for 15 min in separate sessions. The Stroop task-related skin conductance response (SCR) was measured during every task. In addition, the skin conductance level (SCL) and electrocardiograph signals were measured over the course of the experimental procedure. The main findings of the present study were as follows: 1) water immersion decreased the executive task-related sympathetic nervous response, but did not affect executive function as evaluated by Stroop tasks, and 2) decreased SCL induced by water immersion was maintained for at least 15 min after water immersion. In conclusion, the present results suggest that water immersion decreases the sympathetic skin response during the color–word Stroop test without altering executive performance. PMID:28742137

  20. Water immersion decreases sympathetic skin response during color-word Stroop test.

    PubMed

    Sato, Daisuke; Yamazaki, Yudai; Takahashi, Akari; Uetake, Yoshihito; Nakano, Saki; Iguchi, Kaho; Baba, Yasuhiro; Nara, Rio; Shimoyama, Yoshimitsu

    2017-01-01

    Water immersion alters the autonomic nervous system (ANS) response in humans. The effect of water immersion on executive function and ANS responses related to executive function tasks was unknown. Therefore, this study aimed to determine whether water immersion alters ANS response during executive tasks. Fourteen healthy participants performed color-word-matching Stroop tasks before and after non-immersion and water immersion intervention for 15 min in separate sessions. The Stroop task-related skin conductance response (SCR) was measured during every task. In addition, the skin conductance level (SCL) and electrocardiograph signals were measured over the course of the experimental procedure. The main findings of the present study were as follows: 1) water immersion decreased the executive task-related sympathetic nervous response, but did not affect executive function as evaluated by Stroop tasks, and 2) decreased SCL induced by water immersion was maintained for at least 15 min after water immersion. In conclusion, the present results suggest that water immersion decreases the sympathetic skin response during the color-word Stroop test without altering executive performance.

  1. Wind-instrument reflection function measurements in the time domain.

    PubMed

    Keefe, D H

    1996-04-01

    Theoretical and computational analyses of wind-instrument sound production in the time domain have emerged as useful tools for understanding musical instrument acoustics, yet there exist few experimental measurements of the air-column response directly in the time domain. A new experimental, time-domain technique is proposed to measure the reflection function response of woodwind and brass-instrument air columns. This response is defined at the location of sound regeneration in the mouthpiece or double reed. A probe assembly comprised of an acoustic source and microphone is inserted directly into the air column entryway using a foam plug to ensure a leak-free fit. An initial calibration phase involves measurements on a single cylindrical tube of known dimensions. Measurements are presented on an alto saxophone and euphonium. The technique has promise for testing any musical instrument air columns using a single probe assembly and foam plugs over a range of diameters typical of air-column entryways.

  2. Plant functional group responses to fire frequency and tree canopy cover gradients in oak savannas and woodlands.

    Treesearch

    D.W. Peterson; P.B. Reich; K.J. Wrage

    2007-01-01

    We measured plant functional group cover and tree canopy cover on permanent plots within a long-term prescribed fire frequency experiment and used hierarchical linear modeling to assess plant functional group responses to fire frequency and tree canopy cover. Understory woody plant cover was highest in unburned woodlands and was negatively correlated with fire...

  3. Measurement of global functional performance in patients with rheumatoid arthritis using rheumatology function tests

    PubMed Central

    Escalante, Agustín; Haas, Roy W; del Rincón, Inmaculada

    2004-01-01

    Outcome assessment in patients with rheumatoid arthritis (RA) includes measurement of physical function. We derived a scale to quantify global physical function in RA, using three performance-based rheumatology function tests (RFTs). We measured grip strength, walking velocity, and shirt button speed in consecutive RA patients attending scheduled appointments at six rheumatology clinics, repeating these measurements after a median interval of 1 year. We extracted the underlying latent variable using principal component factor analysis. We used the Bayesian information criterion to assess the global physical function scale's cross-sectional fit to criterion standards. The criteria were joint tenderness, swelling, and deformity, pain, physical disability, current work status, and vital status at 6 years after study enrolment. We computed Guyatt's responsiveness statistic for improvement according to the American College of Rheumatology (ACR) definition. Baseline functional performance data were available for 777 patients, and follow-up data were available for 681. Mean ± standard deviation for each RFT at baseline were: grip strength, 14 ± 10 kg; walking velocity, 194 ± 82 ft/min; and shirt button speed, 7.1 ± 3.8 buttons/min. Grip strength and walking velocity departed significantly from normality. The three RFTs loaded strongly on a single factor that explained ≥70% of their combined variance. We rescaled the factor to vary from 0 to 100. Its mean ± standard deviation was 41 ± 20, with a normal distribution. The new global scale had a stronger fit than the primary RFT to most of the criterion standards. It correlated more strongly with physical disability at follow-up and was more responsive to improvement defined according to the ACR20 and ACR50 definitions. We conclude that a performance-based physical function scale extracted from three RFTs has acceptable distributional and measurement properties and is responsive to clinically meaningful change. It provides a parsimonious scale to measure global physical function in RA. PMID:15225367

  4. A Comparison of Measurement Equivalence Methods Based on Confirmatory Factor Analysis and Item Response Theory.

    ERIC Educational Resources Information Center

    Flowers, Claudia P.; Raju, Nambury S.; Oshima, T. C.

    Current interest in the assessment of measurement equivalence emphasizes two methods of analysis, linear, and nonlinear procedures. This study simulated data using the graded response model to examine the performance of linear (confirmatory factor analysis or CFA) and nonlinear (item-response-theory-based differential item function or IRT-Based…

  5. Differential item functioning magnitude and impact measures from item response theory models.

    PubMed

    Kleinman, Marjorie; Teresi, Jeanne A

    2016-01-01

    Measures of magnitude and impact of differential item functioning (DIF) at the item and scale level, respectively are presented and reviewed in this paper. Most measures are based on item response theory models. Magnitude refers to item level effect sizes, whereas impact refers to differences between groups at the scale score level. Reviewed are magnitude measures based on group differences in the expected item scores and impact measures based on differences in the expected scale scores. The similarities among these indices are demonstrated. Various software packages are described that provide magnitude and impact measures, and new software presented that computes all of the available statistics conveniently in one program with explanations of their relationships to one another.

  6. Dopamine reward prediction error responses reflect marginal utility.

    PubMed

    Stauffer, William R; Lak, Armin; Schultz, Wolfram

    2014-11-03

    Optimal choices require an accurate neuronal representation of economic value. In economics, utility functions are mathematical representations of subjective value that can be constructed from choices under risk. Utility usually exhibits a nonlinear relationship to physical reward value that corresponds to risk attitudes and reflects the increasing or decreasing marginal utility obtained with each additional unit of reward. Accordingly, neuronal reward responses coding utility should robustly reflect this nonlinearity. In two monkeys, we measured utility as a function of physical reward value from meaningful choices under risk (that adhered to first- and second-order stochastic dominance). The resulting nonlinear utility functions predicted the certainty equivalents for new gambles, indicating that the functions' shapes were meaningful. The monkeys were risk seeking (convex utility function) for low reward and risk avoiding (concave utility function) with higher amounts. Critically, the dopamine prediction error responses at the time of reward itself reflected the nonlinear utility functions measured at the time of choices. In particular, the reward response magnitude depended on the first derivative of the utility function and thus reflected the marginal utility. Furthermore, dopamine responses recorded outside of the task reflected the marginal utility of unpredicted reward. Accordingly, these responses were sufficient to train reinforcement learning models to predict the behaviorally defined expected utility of gambles. These data suggest a neuronal manifestation of marginal utility in dopamine neurons and indicate a common neuronal basis for fundamental explanatory constructs in animal learning theory (prediction error) and economic decision theory (marginal utility). Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  7. Validity and measurement precision of the PROMIS physical function item bank and a content validity-driven 20-item short form in rheumatoid arthritis compared with traditional measures.

    PubMed

    Oude Voshaar, Martijn A H; Ten Klooster, Peter M; Glas, Cees A W; Vonkeman, Harald E; Taal, Erik; Krishnan, Eswar; Bernelot Moens, Hein J; Boers, Maarten; Terwee, Caroline B; van Riel, Piet L C M; van de Laar, Mart A F J

    2015-12-01

    To evaluate the content validity and measurement properties of the Patient-Reported Outcome Measurement Information System (PROMIS) physical function item bank and a 20-item short form in patients with RA in comparison with the HAQ disability index (HAQ-DI) and 36-item Short Form Health Survey (SF-36) physical functioning scale (PF-10). The content validity of the instruments was evaluated by linking their items to the International Classification of Functioning, Disability and Health (ICF) core set for RA. The measures were administered to 690 RA patients enrolled in the Dutch Rheumatoid Arthritis Monitoring registry. Measurement precision was evaluated using item response theory methods and construct validity was evaluated by correlating physical function scores with other clinical and patient-reported outcome measures. All 207 health concepts identified in the physical function measures referred to activities that are featured in the ICF. Twenty-three of 26 ICF RA core set domains are featured in the full PROMIS physical function item bank compared with 13 and 8 for the HAQ-DI and PF-10, respectively. As hypothesized, all three physical function instruments were highly intercorrelated (r 0.74-0.84), moderately correlated with disease activity measures (r 0.44-0.63) and weakly correlated with age (rs 0.07-0.14). Item response theory-based analysis revealed that a 20-item PROMIS physical function short form covered a wider range of physical function levels than the HAQ-DI or PF-10. The PROMIS physical function item bank demonstrated excellent measurement properties in RA. A content-driven 20-item short form may be a useful tool for assessing physical function in RA. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. An Implicit Measure of Associations with Mental Illness versus Physical Illness: Response Latency Decomposition and Stimuli Differential Functioning in Relation to IAT Order of Associative Conditions and Accuracy

    PubMed Central

    Mannarini, Stefania; Boffo, Marilisa

    2014-01-01

    The present study aimed at the definition of a latent measurement dimension underlying an implicit measure of automatic associations between the concept of mental illness and the psychosocial and biogenetic causal explanatory attributes. To this end, an Implicit Association Test (IAT) assessing the association between the Mental Illness and Physical Illness target categories to the Psychological and Biologic attribute categories, representative of the causal explanation domains, was developed. The IAT presented 22 stimuli (words and pictures) to be categorized into the four categories. After 360 university students completed the IAT, a Many-Facet Rasch Measurement (MFRM) modelling approach was applied. The model specified a person latency parameter and a stimulus latency parameter. Two additional parameters were introduced to denote the order of presentation of the task associative conditions and the general response accuracy. Beyond the overall definition of the latent measurement dimension, the MFRM was also applied to disentangle the effect of the task block order and the general response accuracy on the stimuli response latency. Further, the MFRM allowed detecting any differential functioning of each stimulus in relation to both block ordering and accuracy. The results evidenced: a) the existence of a latency measurement dimension underlying the Mental Illness versus Physical Illness - Implicit Association Test; b) significant effects of block order and accuracy on the overall latency; c) a differential functioning of specific stimuli. The results of the present study can contribute to a better understanding of the functioning of an implicit measure of semantic associations with mental illness and give a first blueprint for the examination of relevant issues in the development of an IAT. PMID:25000406

  9. An implicit measure of associations with mental illness versus physical illness: response latency decomposition and stimuli differential functioning in relation to IAT order of associative conditions and accuracy.

    PubMed

    Mannarini, Stefania; Boffo, Marilisa

    2014-01-01

    The present study aimed at the definition of a latent measurement dimension underlying an implicit measure of automatic associations between the concept of mental illness and the psychosocial and biogenetic causal explanatory attributes. To this end, an Implicit Association Test (IAT) assessing the association between the Mental Illness and Physical Illness target categories to the Psychological and Biologic attribute categories, representative of the causal explanation domains, was developed. The IAT presented 22 stimuli (words and pictures) to be categorized into the four categories. After 360 university students completed the IAT, a Many-Facet Rasch Measurement (MFRM) modelling approach was applied. The model specified a person latency parameter and a stimulus latency parameter. Two additional parameters were introduced to denote the order of presentation of the task associative conditions and the general response accuracy. Beyond the overall definition of the latent measurement dimension, the MFRM was also applied to disentangle the effect of the task block order and the general response accuracy on the stimuli response latency. Further, the MFRM allowed detecting any differential functioning of each stimulus in relation to both block ordering and accuracy. The results evidenced: a) the existence of a latency measurement dimension underlying the Mental Illness versus Physical Illness - Implicit Association Test; b) significant effects of block order and accuracy on the overall latency; c) a differential functioning of specific stimuli. The results of the present study can contribute to a better understanding of the functioning of an implicit measure of semantic associations with mental illness and give a first blueprint for the examination of relevant issues in the development of an IAT.

  10. Formative versus Reflective Measurement of Executive Function Tasks: Response to Commentaries and Another Perspective

    ERIC Educational Resources Information Center

    Willoughby, Michael T.

    2014-01-01

    The focus article (Willoughby et al., 2014) (1) introduced the distinction between formative and reflective measurement and (2) proposed that performance-based executive function tasks may be better conceptualized from the perspective of formative rather than reflective measurement. This proposal stands in sharp contrast to conventional…

  11. Physiologic measures of sexual function in women: a review.

    PubMed

    Woodard, Terri L; Diamond, Michael P

    2009-07-01

    To review and describe physiologic measures of assessing sexual function in women. Literature review. Studies that use instruments designed to measure female sexual function. Women participating in studies of female sexual function. Various instruments that measure physiologic features of female sexual function. Appraisal of the various instruments, including their advantages and disadvantages. Many unique physiologic methods of evaluating female sexual function have been developed during the past four decades. Each method has its benefits and limitations. Many physiologic methods exist, but most are not well-validated. In addition there has been an inability to correlate most physiologic measures with subjective measures of sexual arousal. Furthermore, given the complex nature of the sexual response in women, physiologic measures should be considered in context of other data, including the history, physical examination, and validated questionnaires. Nonetheless, the existence of appropriate physiologic measures is vital to our understanding of female sexual function and dysfunction.

  12. Ion temperature measurements of indirect-drive implosions with the neutron time-of-flight detector on SG-III laser facility

    NASA Astrophysics Data System (ADS)

    Chen, Zhongjing; Zhang, Xing; Pu, Yudong; Yan, Ji; Huang, Tianxuan; Jiang, Wei; Yu, Bo; Chen, Bolun; Tang, Qi; Song, Zifeng; Chen, Jiabin; Zhan, Xiayu; Liu, Zhongjie; Xie, Xufei; Jiang, Shaoen; Liu, Shenye

    2018-02-01

    The accuracy of the determination of the burn-averaged ion temperature of inertial confinement fusion implosions depends on the unfold process, including deconvolution and convolution methods, and the function, i.e., the detector response, used to fit the signals measured by neutron time-of-flight (nToF) detectors. The function given by Murphy et al. [Rev. Sci. Instrum. 68(1), 610-613 (1997)] has been widely used in Nova, Omega, and NIF. There are two components, i.e., fast and slow, and the contribution of scattered neutrons has not been dedicatedly considered. In this work, a new function, based on Murphy's function has been employed to unfold nToF signals. The contribution of scattered neutrons is easily included by the convolution of a Gaussian response function and an exponential decay. The ion temperature is measured by nToF with the new function. Good agreement with the ion temperature determined by the deconvolution method has been achieved.

  13. Why is impaired sexual function distressing to women? The primacy of pleasure in female sexual dysfunction

    PubMed Central

    Stephenson, Kyle R.; Meston, Cindy M.

    2015-01-01

    Introduction Recent research has highlighted a complex association between female sexual function and subjective distress regarding sexual activity. These findings are difficult to explain given limited knowledge as to the mechanisms through which impaired sexual function causes distress. Aim The current study assessed whether a number of specific consequences of impaired sexual function, including decreased physical pleasure, disruption of sexual activity, and negative partner responses, mediated the association between sexual function and distress. Methods Eighty seven women in sexually active relationships reporting impairments in sexual function completed validated self-report measures and daily online assessments of sexual experiences. Main Outcome Measures Participants completed the Sexual Satisfaction Scale for Women (SSS-W), the Female Sexual Function Index (FSFI), and the Measure of Sexual Consequences (MSC). Results Results suggested that decreased physical pleasure and disruption of sexual activity, but not partner responses, statistically mediated the association between sexual function and distress. Conclusion Sexual consequences represent potential maintaining factors of sexual dysfunction that are highly distressing to women. Results are discussed in the context of theoretical models of sexual dysfunction and related treatments. PMID:25556719

  14. INVASIVE PLANTS HARBOR HUNGRY DETRITIVORES THAT ALTER ECOSYSTEM FUNCTION

    EPA Science Inventory

    Ecosystems are expected to function more efficiently in response to a diverse community of inhabitants. However, biological invasions may change expected relationships between ecosystem function and diversity. We observed increased decomposition, a measure of ecosystem function...

  15. SU-G-BRB-14: Uncertainty of Radiochromic Film Based Relative Dose Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Devic, S; Tomic, N; DeBlois, F

    2016-06-15

    Purpose: Due to inherently non-linear dose response, measurement of relative dose distribution with radiochromic film requires measurement of absolute dose using a calibration curve following previously established reference dosimetry protocol. On the other hand, a functional form that converts the inherently non-linear dose response curve of the radiochromic film dosimetry system into linear one has been proposed recently [Devic et al, Med. Phys. 39 4850–4857 (2012)]. However, there is a question what would be the uncertainty of such measured relative dose. Methods: If the relative dose distribution is determined going through the reference dosimetry system (conversion of the response bymore » using calibration curve into absolute dose) the total uncertainty of such determined relative dose will be calculated by summing in quadrature total uncertainties of doses measured at a given and at the reference point. On the other hand, if the relative dose is determined using linearization method, the new response variable is calculated as ζ=a(netOD)n/ln(netOD). In this case, the total uncertainty in relative dose will be calculated by summing in quadrature uncertainties for a new response function (σζ) for a given and the reference point. Results: Except at very low doses, where the measurement uncertainty dominates, the total relative dose uncertainty is less than 1% for the linear response method as compared to almost 2% uncertainty level for the reference dosimetry method. The result is not surprising having in mind that the total uncertainty of the reference dose method is dominated by the fitting uncertainty, which is mitigated in the case of linearization method. Conclusion: Linearization of the radiochromic film dose response provides a convenient and a more precise method for relative dose measurements as it does not require reference dosimetry and creation of calibration curve. However, the linearity of the newly introduced function must be verified. Dave Lewis is inventor and runs a consulting company for radiochromic films.« less

  16. Responsiveness of the cervical Northern American Spine Society questionnaire (NASS) and the Short Form 36 (SF-36) in chronic whiplash.

    PubMed

    Angst, Felix; Verra, Martin L; Lehmann, Susanne; Gysi, Françoise; Benz, Thomas; Aeschlimann, André

    2012-02-01

    To determine and compare the sensitivity to change of the condition-specific cervical Northern American Spine Society (NASS) and the generic Short Form 36 (SF-36). Prospective cohort study. One hundred and seventy five patients after whiplash injury. Four-week inpatient interdisciplinary pain management programme. MAIN MEASURES, ANALYSIS: Responsiveness of the NASS and the SF-36 was quantified by effect size and standardized response mean and compared within the same construct by the modified Jacknife test. Ability to detect improvement was compared using sensitivities determined from receiver operating characteristics curves. In pain, the NASS was comparable responsive to the SF-36 at the one-month follow-up (n = 175): effect sizes: 0.62 (NASS) versus 0.61 (SF-36), P = 0.914. The NASS was less responsive than the SF-36 in function: 0.23 versus 0.63, P < 0.001 and in pain+function: 0.35 versus 0.58 (P = 0.001). These relationships remained consistent using standardized response means, at the six-month follow-up (n = 103), and in the comparison of the sensitivities. Sensitivities at one month, pain: 70% (NASS) versus 62% (SF-36), P = 0.234; function: 65% versus 80%, P = 0.002; pain+function: 68% versus 78%, P = 0.035. The six-month data were similar. The generic SF-36 was more responsive in function and equally responsive in pain when compared to the condition-specific NASS. The SF-36 can be recommended as a responsive instrument for measurement of pain and function in chronic whiplash syndrome.

  17. Different Signal Enhancement Pathways of Attention and Consciousness Underlie Perception in Humans.

    PubMed

    van Boxtel, Jeroen J A

    2017-06-14

    It is not yet known whether attention and consciousness operate through similar or largely different mechanisms. Visual processing mechanisms are routinely characterized by measuring contrast response functions (CRFs). In this report, behavioral CRFs were obtained in humans (both males and females) by measuring afterimage durations over the entire range of inducer stimulus contrasts to reveal visual mechanisms behind attention and consciousness. Deviations relative to the standard CRF, i.e., gain functions, describe the strength of signal enhancement, which were assessed for both changes due to attentional task and conscious perception. It was found that attention displayed a response-gain function, whereas consciousness displayed a contrast-gain function. Through model comparisons, which only included contrast-gain modulations, both contrast-gain and response-gain effects can be explained with a two-level normalization model, in which consciousness affects only the first level and attention affects only the second level. These results demonstrate that attention and consciousness can effectively show different gain functions because they operate through different signal enhancement mechanisms. SIGNIFICANCE STATEMENT The relationship between attention and consciousness is still debated. Mapping contrast response functions (CRFs) has allowed (neuro)scientists to gain important insights into the mechanistic underpinnings of visual processing. Here, the influence of both attention and consciousness on these functions were measured and they displayed a strong dissociation. First, attention lowered CRFs, whereas consciousness raised them. Second, attention manifests itself as a response-gain function, whereas consciousness manifests itself as a contrast-gain function. Extensive model comparisons show that these results are best explained in a two-level normalization model in which consciousness affects only the first level, whereas attention affects only the second level. These findings show dissociations between both the computational mechanisms behind attention and consciousness and the perceptual consequences that they induce. Copyright © 2017 the authors 0270-6474/17/375912-11$15.00/0.

  18. Calculation of the static in-flight telescope-detector response by deconvolution applied to point-spread function for the geostationary earth radiation budget experiment.

    PubMed

    Matthews, Grant

    2004-12-01

    The Geostationary Earth Radiation Budget (GERB) experiment is a broadband satellite radiometer instrument program intended to resolve remaining uncertainties surrounding the effect of cloud radiative feedback on future climate change. By use of a custom-designed diffraction-aberration telescope model, the GERB detector spatial response is recovered by deconvolution applied to the ground calibration point-spread function (PSF) measurements. An ensemble of randomly generated white-noise test scenes, combined with the measured telescope transfer function results in the effect of noise on the deconvolution being significantly reduced. With the recovered detector response as a base, the same model is applied in construction of the predicted in-flight field-of-view response of each GERB pixel to both short- and long-wave Earth radiance. The results of this study can now be used to simulate and investigate the instantaneous sampling errors incurred by GERB. Also, the developed deconvolution method may be highly applicable in enhancing images or PSF data for any telescope system for which a wave-front error measurement is available.

  19. Recovery of balance function among individuals with total knee arthroplasty: Comparison of responsiveness among four balance tests.

    PubMed

    Chan, Andy C M; Ouyang, Xi H; Jehu, Deborah A M; Chung, Raymond C K; Pang, Marco Y C

    2018-01-01

    Balance deficits are common after total knee arthroplasty (TKA); however the responsiveness of commonly used balance measurement tools has not been well defined. The objective of this prospective study was to compare the internal and external responsiveness of four measurement tools in assessing recovery of balance function following TKA. A total of 134 individuals with TKA (95 women; age: 66.3±6.6years) completed the Balance Evaluation Systems Test (BESTest), Mini-BESTest, Brief-BESTest, and Berg Balance Scale (BBS) at 2, 4, 8, 12, and 24 weeks post-TKA. The Functional Gait Assessment (FGA) served as the anchor measure, and was also measured across these time points. Internal responsiveness was indicated by the standardized response mean (SRM), while external responsiveness was reflected by the degree of association of the changes of balance scores with those of FGA. The SRM ranged from 0.60-1.14 for the BESTest, 0.40-0.94 for the Mini-BESTest, 0.27-0.91 for the Brief-BESTest, and 0.19-0.70 for the BBS, over time. The change in BESTest and Mini-BESTest scores predicted the change in the FGA scores across all time periods, except for the Mini-BESTest between weeks 12-24, accounting for 13-27%, and 12-24% of the variance, respectively. The Brief-BESTest scores only predicted FGA scores between the weeks 2-4 (R 2 =20%). The changes in BBS scores were not associated with the FGA. The BESTest is the most responsive in measuring recovery of balance among individuals with TKA. The Mini-BESTest is a reasonable option during time constraints. Copyright © 2017. Published by Elsevier B.V.

  20. Out-of-plane measurements of the fifth response function of the exclusive electronuclear response

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dolfini, S. M.; Arizona State University, Tempe, Arizona 85287-1504; Alarcon, R. O.

    1999-12-01

    The first measurements of f{sub LT}{sup '}, known as the fifth response function, have been made for the {sup 2}H(e(vector sign),e{sup '}p) and {sup 12}C(e(vector sign),e{sup '}p) reactions. This response is directly related to the imaginary part of the interference between the transverse and longitudinal nuclear electromagnetic currents. Its observation requires longitudinally polarized electron beams and out-of-plane detection, the latter made possible by the newly developed out-of-plane spectrometer system. The initial measurements were made by using a 560-MeV polarized electron beam and quasielastic kinematics at Q{sup 2}=3.3 fm{sup -2}. The development of the methodology for out-of-plane physics, and the analysismore » of the data from the initial experiments are described in detail. The measured fifth response and the related asymmetry in the coincidence cross section are in agreement, albeit with large statistical errors, with the theoretical predictions. Future extensions of the out-of-plane program are also discussed. (c) 1999 The American Physical Society.« less

  1. Capturing Pain in the Cortex during General Anesthesia: Near Infrared Spectroscopy Measures in Patients Undergoing Catheter Ablation of Arrhythmias

    PubMed Central

    Yücel, Meryem A.; Steele, Sarah C.; Alexander, Mark E.; Boas, David A.; Borsook, David; Becerra, Lino

    2016-01-01

    The predictability of pain makes surgery an ideal model for the study of pain and the development of strategies for analgesia and reduction of perioperative pain. As functional near-infrared spectroscopy reproduces the known functional magnetic resonance imaging activations in response to a painful stimulus, we evaluated the feasibility of functional near-infrared spectroscopy to measure cortical responses to noxious stimulation during general anesthesia. A multichannel continuous wave near-infrared imager was used to measure somatosensory and frontal cortical activation in patients undergoing catheter ablation of arrhythmias under general anesthesia. Anesthetic technique was standardized and intraoperative NIRS signals recorded continuously with markers placed in the data set for the timing and duration of each cardiac ablation event. Frontal cortical signals only were suitable for analysis in five of eight patients studied (mean age 14 ± 1 years, weight 66.7 ± 17.6 kg, 2 males). Thirty ablative lesions were recorded for the five patients. Radiofrequency or cryoablation was temporally associated with a hemodynamic response function in the frontal cortex characterized by a significant decrease in oxyhemoglobin concentration (paired t-test, p<0.05) with the nadir occurring in the period 4 to 6 seconds after application of the ablative lesion. Cortical signals produced by catheter ablation of arrhythmias in patients under general anesthesia mirrored those seen with noxious stimulation in awake, healthy volunteers, during sedation for colonoscopy, and functional Magnetic Resonance Imaging activations in response to pain. This study demonstrates the feasibility and potential utility of functional near-infrared spectroscopy as an objective measure of cortical activation under general anesthesia. PMID:27415436

  2. Capturing Pain in the Cortex during General Anesthesia: Near Infrared Spectroscopy Measures in Patients Undergoing Catheter Ablation of Arrhythmias.

    PubMed

    Kussman, Barry D; Aasted, Christopher M; Yücel, Meryem A; Steele, Sarah C; Alexander, Mark E; Boas, David A; Borsook, David; Becerra, Lino

    2016-01-01

    The predictability of pain makes surgery an ideal model for the study of pain and the development of strategies for analgesia and reduction of perioperative pain. As functional near-infrared spectroscopy reproduces the known functional magnetic resonance imaging activations in response to a painful stimulus, we evaluated the feasibility of functional near-infrared spectroscopy to measure cortical responses to noxious stimulation during general anesthesia. A multichannel continuous wave near-infrared imager was used to measure somatosensory and frontal cortical activation in patients undergoing catheter ablation of arrhythmias under general anesthesia. Anesthetic technique was standardized and intraoperative NIRS signals recorded continuously with markers placed in the data set for the timing and duration of each cardiac ablation event. Frontal cortical signals only were suitable for analysis in five of eight patients studied (mean age 14 ± 1 years, weight 66.7 ± 17.6 kg, 2 males). Thirty ablative lesions were recorded for the five patients. Radiofrequency or cryoablation was temporally associated with a hemodynamic response function in the frontal cortex characterized by a significant decrease in oxyhemoglobin concentration (paired t-test, p<0.05) with the nadir occurring in the period 4 to 6 seconds after application of the ablative lesion. Cortical signals produced by catheter ablation of arrhythmias in patients under general anesthesia mirrored those seen with noxious stimulation in awake, healthy volunteers, during sedation for colonoscopy, and functional Magnetic Resonance Imaging activations in response to pain. This study demonstrates the feasibility and potential utility of functional near-infrared spectroscopy as an objective measure of cortical activation under general anesthesia.

  3. Combining classifiers to predict gene function in Arabidopsis thaliana using large-scale gene expression measurements.

    PubMed

    Lan, Hui; Carson, Rachel; Provart, Nicholas J; Bonner, Anthony J

    2007-09-21

    Arabidopsis thaliana is the model species of current plant genomic research with a genome size of 125 Mb and approximately 28,000 genes. The function of half of these genes is currently unknown. The purpose of this study is to infer gene function in Arabidopsis using machine-learning algorithms applied to large-scale gene expression data sets, with the goal of identifying genes that are potentially involved in plant response to abiotic stress. Using in house and publicly available data, we assembled a large set of gene expression measurements for A. thaliana. Using those genes of known function, we first evaluated and compared the ability of basic machine-learning algorithms to predict which genes respond to stress. Predictive accuracy was measured using ROC50 and precision curves derived through cross validation. To improve accuracy, we developed a method for combining these classifiers using a weighted-voting scheme. The combined classifier was then trained on genes of known function and applied to genes of unknown function, identifying genes that potentially respond to stress. Visual evidence corroborating the predictions was obtained using electronic Northern analysis. Three of the predicted genes were chosen for biological validation. Gene knockout experiments confirmed that all three are involved in a variety of stress responses. The biological analysis of one of these genes (At1g16850) is presented here, where it is shown to be necessary for the normal response to temperature and NaCl. Supervised learning methods applied to large-scale gene expression measurements can be used to predict gene function. However, the ability of basic learning methods to predict stress response varies widely and depends heavily on how much dimensionality reduction is used. Our method of combining classifiers can improve the accuracy of such predictions - in this case, predictions of genes involved in stress response in plants - and it effectively chooses the appropriate amount of dimensionality reduction automatically. The method provides a useful means of identifying genes in A. thaliana that potentially respond to stress, and we expect it would be useful in other organisms and for other gene functions.

  4. Nonlinear experimental dye-doped nematic liquid crystal optical transmission spectra estimated by neural network empirical physical formulas

    NASA Astrophysics Data System (ADS)

    Yildiz, Nihat; San, Sait Eren; Köysal, Oğuz

    2010-09-01

    In this paper, two complementary objectives related to optical transmission spectra of nematic liquid crystals (NLCs) were achieved. First, at room temperature, for both pure and dye (DR9) doped E7 NLCs, the 10-250 W halogen lamp transmission spectra (wavelength 400-1200 nm) were measured at various bias voltages. Second, because the measured spectra were inherently highly nonlinear, it was difficult to construct explicit empirical physical formulas (EPFs) to employ as transmittance functions. To avoid this difficulty, layered feedforward neural networks (LFNNs) were used to construct explicit EPFs for these theoretically unknown nonlinear NLC transmittance functions. As we theoretically showed in a previous work, a LFNN, as an excellent nonlinear function approximator, is highly relevant to EPF construction. The LFNN-EPFs efficiently and consistently estimated both the measured and yet-to-be-measured nonlinear transmittance response values. The experimentally obtained doping ratio dependencies and applied bias voltage responses of transmittance were also confirmed by LFFN-EPFs. This clearly indicates that physical laws embedded in the physical data can be faithfully extracted by the suitable LFNNs. The extraordinary success achieved with LFNN here suggests two potential applications. First, although not attempted here, these LFNN-EPFs, by such mathematical operations as derivation, integration, minimization etc., can be used to obtain further transmittance related functions of NLCs. Second, for a given NLC response function, whose theoretical nonlinear functional form is yet unknown, a suitable experimental data based LFNN-EPF can be constructed to predict the yet-to-be-measured values.

  5. Neutron response function characterization of 4He scintillation detectors

    DOE PAGES

    Kelley, Ryan P.; Rolison, Lucas M.; Lewis, Jason M.; ...

    2015-04-15

    Time-of-flight measurements were conducted to characterize the neutron energy response of pressurized 4He fast neutron scintillation detectors for the first time, using the Van de Graaff generator at Ohio University. The time-of-flight spectra and pulse height distributions were measured. This data was used to determine the light output response function, which was found to be linear at energies below 3.5 MeV. The intrinsic efficiency of the detector as a function of incident energy was also calculated: the average efficiency up to 10 MeV was 3.1%, with a maximum efficiency of 6.6% at 1.05 MeV. Furthermore, these results will enable developmentmore » of neutron spectrum unfolding algorithms for neutron spectroscopy applications with these detectors.« less

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Devic, Slobodan; Tomic, Nada; Aldelaijan, Saad

    Purpose: Despite numerous advantages of radiochromic film dosimeter (high spatial resolution, near tissue equivalence, low energy dependence) to measure a relative dose distribution with film, one needs to first measure an absolute dose (following previously established reference dosimetry protocol) and then convert measured absolute dose values into relative doses. In this work, we present result of our efforts to obtain a functional form that would linearize the inherently nonlinear dose-response curve of the radiochromic film dosimetry system. Methods: Functional form [{zeta}= (-1){center_dot}netOD{sup (2/3)}/ln(netOD)] was derived from calibration curves of various previously established radiochromic film dosimetry systems. In order to testmore » the invariance of the proposed functional form with respect to the film model used we tested it with three different GAFCHROMIC Trade-Mark-Sign film models (EBT, EBT2, and EBT3) irradiated to various doses and scanned on a same scanner. For one of the film models (EBT2), we tested the invariance of the functional form to the scanner model used by scanning irradiated film pieces with three different flatbed scanner models (Epson V700, 1680, and 10000XL). To test our hypothesis that the proposed functional argument linearizes the response of the radiochromic film dosimetry system, verification tests have been performed in clinical applications: percent depth dose measurements, IMRT quality assurance (QA), and brachytherapy QA. Results: Obtained R{sup 2} values indicate that the choice of the functional form of the new argument appropriately linearizes the dose response of the radiochromic film dosimetry system we used. The linear behavior was insensitive to both film model and flatbed scanner model used. Measured PDD values using the green channel response of the GAFCHROMIC Trade-Mark-Sign EBT3 film model are well within {+-}2% window of the local relative dose value when compared to the tabulated Cobalt-60 data. It was also found that criteria of 3%/3 mm for an IMRT QA plan and 3%/2 mm for a brachytherapy QA plan are passing 95% gamma function points. Conclusions: In this paper, we demonstrate the use of functional argument to linearize the inherently nonlinear response of a radiochromic film based reference dosimetry system. In this way, relative dosimetry can be conveniently performed using radiochromic film dosimetry system without the need of establishing calibration curve.« less

  7. Comparison of Nasal Potential Difference and Intestinal Current Measurements as Surrogate Markers for CFTR Function.

    PubMed

    Wilschanski, Michael; Yaakov, Yasmin; Omari, Ibrahim; Zaman, Munir; Martin, Camilia R; Cohen-Cymberknoh, Malena; Shoseyov, David; Kerem, Eitan; Dasilva, Deborah; Sheth, Sunil; Uluer, Ahmet; OʼSullivan, Brian P; Freedman, Steven

    2016-11-01

    Nasal potential difference (NPD) measurement is part of the diagnostic criteria for cystic fibrosis (CF) and now used routinely as an endpoint in clinical trials of correcting the basic defect in CF. Intestinal current measurement (ICM), measured ex vivo on a rectal biopsy, has been used to study cystic fibrosis transmembrane conductance regulator (CFTR) function but has not been compared to NPD in the same subject in adults and children. The aim of the study is to evaluate the potential usefulness of ICM as a marker of CFTR function for treatment studies compared NPD in patients with CF and in healthy control subjects. ICM and NPD were performed on healthy controls and patients with CF. The healthy adults were individuals undergoing routine screening colonoscopy at the Beth Israel Deaconess Medical Center. The healthy children were undergoing colonoscopy for suspicion of inflammation in Hadassah Hebrew University Medical Center. The CF adults were recruited from Boston Children's Hospital CF Center and CF Center Worcester Mass, the children with CF from Hadassah CF Center. ICM measurements in healthy control subjects (n = 16) demonstrated a mean (±SE) carbachol response of 16.0 (2.2) μA/cm, histamine response of 13.2 (2.1) μA/cm and a forskolin response of 6.3 (2.0) μA/cm. Basal NPD of -15.9 (1.9) and response to Cl free + isoproterenol of -13.8 (2.0). These responses were inverted in CF subjects (n = 12) for ICM parameters with carbachol response of -3.0 (0.5) μA/cm, histamine -1.0 (0.8) μA/cm and a forskolin response of 0.5 (0.3) and also for NPD parameters; basal NPD of -42.2 (4.3) and response to Cl free + isoproterenol of 4.3 (0.7). Pearson correlation test showed the comparability of ICM and NPD in assessing CFTR function. ICM is equivalent to NPD in the ability to distinguish patients with CF from controls and could be used as surrogate markers of CFTR activity in treatment protocols.

  8. Normal and abnormal human vestibular ocular function

    NASA Technical Reports Server (NTRS)

    Peterka, R. J.; Black, F. O.

    1986-01-01

    The major motivation of this research is to understand the role the vestibular system plays in sensorimotor interactions which result in spatial disorientation and motion sickness. A second goal was to explore the range of abnormality as it is reflected in quantitative measures of vestibular reflex responses. The results of a study of vestibular reflex measurements in normal subjects and preliminary results in abnormal subjects are presented in this report. Statistical methods were used to define the range of normal responses, and determine age related changes in function.

  9. The Use of Dispersion Relations For The Geomagnetic Transfer Functions

    NASA Astrophysics Data System (ADS)

    Marcuello, A.; Queralt, P.; Ledo, J. J.

    The magnetotelluric responses are complex magnitudes, where real and imaginary parts contain the same information on the geoelectrical structure. It seems possible, from very general hypotheses on the geoelectrical models (causality, stability and passivity), to apply the Kramers-Krönig dispersion relations to the magnetotelluric responses (impedance, geomagnetic transfer functions,...). In particular, the applica- bility of these relations to the impedance is a current point of discussion, but there are not many examples of their application to the geomagnetic transfer functions (tipper). The aim of this paper is to study how the relations of dispersion are applied to the real and imaginary part of the geomagnetic transfer functions, and to check its validity. For this reason, we have considered data (or responses) from two- and three-dimensional structures, and for these data, we have taken two situations: 1.- Responses that have been synthetically generated from numerical modelling, that allows us to control the quality of the data. 2.- Responses obtained from fieldwork, that are affected by exper- imental error. Additionally, we have also explored the use of these relations to extrap- olate the geomagnetic transfer functions outside the interval of measured frequencies, in order to obtain constrains on the values of these extrapolated data. The results have shown that the dispersion relations are accomplished for the geomag- netic transfer functions, and they can offer information about how these responses are behaved outside (but near) the range of measured frequencies.

  10. Ordinal probability effect measures for group comparisons in multinomial cumulative link models.

    PubMed

    Agresti, Alan; Kateri, Maria

    2017-03-01

    We consider simple ordinal model-based probability effect measures for comparing distributions of two groups, adjusted for explanatory variables. An "ordinal superiority" measure summarizes the probability that an observation from one distribution falls above an independent observation from the other distribution, adjusted for explanatory variables in a model. The measure applies directly to normal linear models and to a normal latent variable model for ordinal response variables. It equals Φ(β/2) for the corresponding ordinal model that applies a probit link function to cumulative multinomial probabilities, for standard normal cdf Φ and effect β that is the coefficient of the group indicator variable. For the more general latent variable model for ordinal responses that corresponds to a linear model with other possible error distributions and corresponding link functions for cumulative multinomial probabilities, the ordinal superiority measure equals exp(β)/[1+exp(β)] with the log-log link and equals approximately exp(β/2)/[1+exp(β/2)] with the logit link, where β is the group effect. Another ordinal superiority measure generalizes the difference of proportions from binary to ordinal responses. We also present related measures directly for ordinal models for the observed response that need not assume corresponding latent response models. We present confidence intervals for the measures and illustrate with an example. © 2016, The International Biometric Society.

  11. Preferred modes in jets: comparison between different measures of the receptivity

    NASA Astrophysics Data System (ADS)

    Garnaud, Xavier; Lesshafft, Lutz; Schmid, Peter J.; Huerre, Patrick

    2012-11-01

    The response of jets to frequency forcing is usually measured experimentally in terms of the maximum amplitude of velocity fluctuations reached along the axis (Crow & Champagne (1971)). In the present work, the preferred mode of isothermal jets is discussed in terms of the linear flow response to time-harmonic forcing (Trefethen et al. (1993)). The optimal frequency response is computed for different choices of the objective functional: the usual energy (L2) norm and the maximum amplitude over the entire domain (L∞ norm). The relevance and limitations of the different objective functionals are critically analyzed. Although the dominant flow structures are robustly identified in all cases, the measure of the flow response in terms of the maximum amplitude does not suffer from the continually slow axial growth of low frequency perturbations. The financial support of the EADS Foundation is gratefully acknowledged.

  12. The Impact of Non-attempted and Dually-Attempted Items on Person Abilities Using Item Response Theory

    PubMed Central

    Sideridis, Georgios D.; Tsaousis, Ioannis; Al Harbi, Khaleel

    2016-01-01

    The purpose of the present study was to relate response strategy with person ability estimates. Two behavioral strategies were examined: (a) the strategy to skip items in order to save time on timed tests, and, (b) the strategy to select two responses on an item, with the hope that one of them may be considered correct. Participants were 4,422 individuals who were administered a standardized achievement measure related to math, biology, chemistry, and physics. In the present evaluation, only the physics subscale was employed. Two analyses were conducted: (a) a person-based one to identify differences between groups and potential correlates of those differences, and, (b) a measure-based analysis in order to identify the parts of the measure that were responsible for potential group differentiation. For (a) person abilities the 2-PL model was employed and later the 3-PL and 4-PL models in order to estimate upper and lower asymptotes of person abilities. For (b) differential item functioning, differential test functioning, and differential distractor functioning were investigated. Results indicated that there were significant differences between groups with completers having the highest ability compared to both non-attempters and dual responders. There were no significant differences between no-attempters and dual responders. The present findings have implications for response strategy efficacy and measure evaluation, revision, and construction. PMID:27790174

  13. The Impact of Non-attempted and Dually-Attempted Items on Person Abilities Using Item Response Theory.

    PubMed

    Sideridis, Georgios D; Tsaousis, Ioannis; Al Harbi, Khaleel

    2016-01-01

    The purpose of the present study was to relate response strategy with person ability estimates. Two behavioral strategies were examined: (a) the strategy to skip items in order to save time on timed tests, and, (b) the strategy to select two responses on an item, with the hope that one of them may be considered correct. Participants were 4,422 individuals who were administered a standardized achievement measure related to math, biology, chemistry, and physics. In the present evaluation, only the physics subscale was employed. Two analyses were conducted: (a) a person-based one to identify differences between groups and potential correlates of those differences, and, (b) a measure-based analysis in order to identify the parts of the measure that were responsible for potential group differentiation. For (a) person abilities the 2-PL model was employed and later the 3-PL and 4-PL models in order to estimate upper and lower asymptotes of person abilities. For (b) differential item functioning, differential test functioning, and differential distractor functioning were investigated. Results indicated that there were significant differences between groups with completers having the highest ability compared to both non-attempters and dual responders. There were no significant differences between no-attempters and dual responders. The present findings have implications for response strategy efficacy and measure evaluation, revision, and construction.

  14. Gender Invariance of the Gambling Behavior Scale for Adolescents (GBS-A): An Analysis of Differential Item Functioning Using Item Response Theory.

    PubMed

    Donati, Maria Anna; Chiesi, Francesca; Izzo, Viola A; Primi, Caterina

    2017-01-01

    As there is a lack of evidence attesting the equivalent item functioning across genders for the most employed instruments used to measure pathological gambling in adolescence, the present study was aimed to test the gender invariance of the Gambling Behavior Scale for Adolescents (GBS-A), a new measurement tool to assess the severity of Gambling Disorder (GD) in adolescents. The equivalence of the items across genders was assessed by analyzing Differential Item Functioning within an Item Response Theory framework. The GBS-A was administered to 1,723 adolescents, and the graded response model was employed. The results attested the measurement equivalence of the GBS-A when administered to male and female adolescent gamblers. Overall, findings provided evidence that the GBS-A is an effective measurement tool of the severity of GD in male and female adolescents and that the scale was unbiased and able to relieve truly gender differences. As such, the GBS-A can be profitably used in educational interventions and clinical treatments with young people.

  15. Cerebral Blood Flow and BOLD Responses to a Memory Encoding Task: A Comparison Between Healthy Young and Elderly Adults

    PubMed Central

    Restom, Khaled; Bangen, Katherine J.; Bondi, Mark W.; Perthen, Joanna E.; Liu, Thomas T.

    2007-01-01

    Functional magnetic resonance imaging (fMRI) studies of the medial temporal lobe have primarily made use of the blood oxygenation level dependent (BOLD) response to neural activity. The interpretation of the BOLD signal as a measure of medial temporal lobe function can be complicated, however, by changes in the cerebrovascular system that can occur with both normal aging and age-related diseases, such as Alzheimer's disease. Quantitative measures of the functional cerebral blood flow (CBF) response offer a useful complement to BOLD measures, and have been shown to aid in the interpretation of fMRI studies. Despite these potential advantages, the application of ASL to fMRI studies of cognitive tasks and at-risk populations has been limited. In this study, we demonstrate the application of ASL fMRI to obtain measures of the CBF and BOLD responses to the encoding of natural scenes in healthy young (mean 25 years) and elderly (mean 74 years) adults. The percent CBF increase in the medial temporal lobe was significantly higher in the older adults, whereas the CBF levels during baseline and task conditions and during a separate resting-state scan were significantly lower in the older group. The older adults also showed slightly higher values for the BOLD response amplitude and the absolute change in CBF, but the age group differences were not significant. The percent CBF and BOLD responses are consistent with an age-related increase in the cerebral metabolic rate of oxygen metabolism (CMRO2) response to memory encoding. PMID:17590353

  16. Modal characterization of the ASCIE segmented optics testbed: New algorithms and experimental results

    NASA Technical Reports Server (NTRS)

    Carrier, Alain C.; Aubrun, Jean-Noel

    1993-01-01

    New frequency response measurement procedures, on-line modal tuning techniques, and off-line modal identification algorithms are developed and applied to the modal identification of the Advanced Structures/Controls Integrated Experiment (ASCIE), a generic segmented optics telescope test-bed representative of future complex space structures. The frequency response measurement procedure uses all the actuators simultaneously to excite the structure and all the sensors to measure the structural response so that all the transfer functions are measured simultaneously. Structural responses to sinusoidal excitations are measured and analyzed to calculate spectral responses. The spectral responses in turn are analyzed as the spectral data become available and, which is new, the results are used to maintain high quality measurements. Data acquisition, processing, and checking procedures are fully automated. As the acquisition of the frequency response progresses, an on-line algorithm keeps track of the actuator force distribution that maximizes the structural response to automatically tune to a structural mode when approaching a resonant frequency. This tuning is insensitive to delays, ill-conditioning, and nonproportional damping. Experimental results show that is useful for modal surveys even in high modal density regions. For thorough modeling, a constructive procedure is proposed to identify the dynamics of a complex system from its frequency response with the minimization of a least-squares cost function as a desirable objective. This procedure relies on off-line modal separation algorithms to extract modal information and on least-squares parameter subset optimization to combine the modal results and globally fit the modal parameters to the measured data. The modal separation algorithms resolved modal density of 5 modes/Hz in the ASCIE experiment. They promise to be useful in many challenging applications.

  17. Childhood Social Functioning and Young Adult Intimate Partner Violence in Girls With and Without ADHD: Response Inhibition as a Moderator.

    PubMed

    Youn, Cherry; Meza, Jocelyn I; Hinshaw, Stephen P

    2018-06-01

    Examine the moderating effects of response inhibition on the longitudinal association between social preference/relational aggression measured in childhood, and intimate partner violence (IPV) measured in young adulthood, among women with ( n = 140) and without ( n = 88) histories of childhood ADHD. During childhood, social preference was measured through confidential peer sociometric nominations, yielding negative and positive peer regard; relational aggression was assessed via staff behavioral observations; and response inhibition was assessed using commission errors from the continuous performance task. During young adulthood, IPV was ascertained via a clinician-administered, semistructured interview. Social preference and relational aggression independently predicted IPV; this prospective link was moderated by response inhibition. In combination with low social preference or high relational aggression in childhood, poor response inhibition predicted the highest levels of young-adult IPV. Given the developmental significance of peer relationships, additional research on the causes of and treatments for poor social functioning in ADHD is warranted.

  18. Calculation of response matrix of CaSO 4:Dy based neutron dosimeter using Monte Carlo code FLUKA and measurement of 241Am-Be spectra

    NASA Astrophysics Data System (ADS)

    Chatterjee, S.; Bakshi, A. K.; Tripathy, S. P.

    2010-09-01

    Response matrix for CaSO 4:Dy based neutron dosimeter was generated using Monte Carlo code FLUKA in the energy range thermal to 20 MeV for a set of eight Bonner spheres of diameter 3-12″ including the bare one. Response of the neutron dosimeter was measured for the above set of spheres for 241Am-Be neutron source covered with 2 mm lead. An analytical expression for the response function was devised as a function of sphere mass. Using Frascati Unfolding Iteration Tool (FRUIT) unfolding code, the neutron spectrum of 241Am-Be was unfolded and compared with standard IAEA spectrum for the same.

  19. Readability and Comprehension of the Geriatric Depression Scale and PROMIS® Physical Function Items in Older African Americans and Latinos

    PubMed Central

    Paz, Sylvia H.; Jones, Loretta; Calderón, José L.; Hays, Ron D.

    2016-01-01

    Background Depression and physical function are especially important health domains for the elderly. The Geriatric Depression Scale (GDS) and the Patient-Reported Outcomes Measurement Information System (PROMIS®) Physical Function Item Bank are two surveys commonly used to measure these domains. It is unclear if these two instruments adequately measure these aspects of health in minority elderly. Objective To estimate the readability of the GDS and PROMIS® Physical Function items and to assess their comprehensibility by a sample of African American and Latino elderly. Methods Readability was estimated using the Flesch-Kincaid (F-K) and Flesch-Reading-Ease (FRE) formulae for English versions, and a Spanish adaptation of the FRE formula for the Spanish versions. Comprehension of the GDS and PROMIS items by minority elderly was evaluated with 30 cognitive interviews. Results Readability estimates of a number of items in English and Spanish of the GDS and PROMIS physical functioning items exceed the recommended 5th grade level, or were rated as fairly difficult, difficult, or very difficult to read. Cognitive interviews revealed that many participants felt that more than the two (yes/no) GDS response options were needed to answer the questions. Wording of several PROMIS items was considered confusing and responses potentially uninterpretable because they were based on physical aids. Conclusions Problems with item wording and response options of the GDS and PROMIS Physical Function items may negatively affect reliability and validity of measurement when used with minority elderly. PMID:27599978

  20. The work role functioning questionnaire 2.0 (Dutch version): examination of its reliability, validity and responsiveness in the general working population.

    PubMed

    Abma, Femke I; van der Klink, Jac J L; Bültmann, Ute

    2013-03-01

    The promotion of a sustainable, healthy and productive working life attracts more and more attention. Recently the Work Role Functioning Questionnaire (WRFQ) has been cross-culturally translated and adapted to Dutch. This questionnaire aims to measure the health-related work functioning of workers with health problems. The aim of this study is to evaluate the reliability, validity (including five new items) and responsiveness of the WRFQ 2.0 in the working population. A longitudinal study was conducted among workers. The reliability (internal consistency, test-retest reliability, measurement error), validity (structural validity-factor analysis, construct validity by means of hypotheses testing) and responsiveness of the WRFQ 2.0 were evaluated. A total of N = 553 workers completed the survey. The final WRFQ 2.0 has four subscales and showed very good internal consistency, moderate test-retest reliability, good construct validity and moderate responsiveness in the working population. The WRFQ was able to distinguish between groups with different levels of mental health, physical health, fatigue and need for recovery. A moderate correlation was found between WRFQ and related constructs respectively work ability and work productivity. A weak relationship was found with general self-rated health, work engagement and work involvement. The WRFQ 2.0 is a reliable and valid instrument to measure health-related work functioning in the working population. Further validation in larger samples is recommended, especially for test-retest reliability, responsiveness and the questionnaire's ability to predict the future course of health-related work functioning.

  1. Responsiveness and Minimally Important Differences for 4 Patient-Reported Outcomes Measurement Information System Short Forms: Physical Function, Pain Interference, Depression, and Anxiety in Knee Osteoarthritis.

    PubMed

    Lee, Augustine C; Driban, Jeffrey B; Price, Lori Lyn; Harvey, William F; Rodday, Angie Mae; Wang, Chenchen

    2017-09-01

    Patient-Reported Outcomes Measurement Information System (PROMIS) instruments can provide valid, interpretable measures of health status among adults with osteoarthritis (OA). However, their ability to detect meaningful change over time is unknown. We evaluated the responsiveness and minimally important differences (MIDs) for 4 PROMIS Short Forms: Physical Function, Pain Interference, Depression, and Anxiety. We analyzed adults with symptomatic knee OA from our randomized trial comparing Tai Chi and physical therapy. Using baseline and 12-week scores, responsiveness was evaluated according to consensus standards by testing 6 a priori hypotheses of the correlations between PROMIS and legacy change scores. Responsiveness was considered high if ≥5 hypotheses were confirmed, and moderate if 3 or 4 were confirmed. MIDs were evaluated according to prospective change for people achieving previously-established MID on legacy comparators. The lowest and highest MIDs meeting a priori quality criteria formed a MID range for each PROMIS Short Form. Among 165 predominantly female (70%) and white (57%) participants, mean age was 61 years and body mass index was 33. PROMIS Physical Function had 5 confirmed hypotheses and Pain Interference, Depression, and Anxiety had 3 or 4. MID ranges were: Depression = 3.0 to 3.1; Anxiety = 2.3 to 3.4; Physical Function = 1.9 to 2.2; and Pain Interference = 2.35 to 2.4. PROMIS Physical Function has high responsiveness, and Depression, Anxiety, and Pain Interference have moderate responsiveness among adults with knee OA. We established the first MIDs for PROMIS in this population, and provided an important standard of reference to better apply or interpret PROMIS in future trials or clinical practice. This study examined whether PROMIS Short Form instruments (Physical Function, Pain Interference, Depression, and Anxiety) were able to detect change over time among adults with knee OA, and provided minimally important change estimates for each measure. This standard of reference can help apply or interpret these instruments in the future. Copyright © 2017. Published by Elsevier Inc.

  2. Responsivity calibration of the LoWEUS spectrometer

    DOE PAGES

    Lepson, J. K.; Beiersdorfer, P.; Kaita, R.; ...

    2016-09-02

    We performed an in situ calibration of the relative responsivity function of the Long-Wavelength Extreme Ultraviolet Spectrometer (LoWEUS), while operating on the Lithium Tokamak Experiment (LTX) at Princeton Plasma Physics Laboratory. The calibration was accomplished by measuring oxygen lines, which are typically present in LTX plasmas. The measured spectral line intensities of each oxygen charge state were then compared to the calculated emission strengths given in the CHIANTI atomic database. Normalizing the strongest line in each charge state to the CHIANTI predictions, we obtained the differences between the measured and predicted values for the relative strengths of the other linesmore » of a given charge state. We find that a 3rd degree polynomial function provides a good fit to the data points. Lastly, our measurements show that the responsivity between about 120 and 300 Å varies by factor of ~30.« less

  3. A model-independent comparison of the rates of uptake and short term retention of 47Ca and 85Sr by the skeleton.

    PubMed

    Reeve, J; Hesp, R

    1976-12-22

    1. A method has been devised for comparing the impulse response functions of the skeleton for two or more boneseeking tracers, and for estimating the contribution made by measurement errors to the differences between any pair of impulse response functions. 2. Comparisons were made between the calculated impulse response functions for 47Ca and 85Sr obtained in simultaneous double tracer studies in sixteen subjects. Collectively the differences between the 47Ca and 85Sr functions could be accounted for entirely by measurement errors. 3. Because the calculation of an impulse response function requires fewer a priori assumptions than other forms of mathematical analysis, and automatically corrects for differences induced by recycling of tracer and non-identical rates of excretory plasma clearance of tracer, it is concluded that differences shown in previous in vivo studies between the fluxes of Ca and Sr into bone can be fully accounted for by undetermined oversimplifications in the various mathematical models used to analyse the results of those studies. 85Sr is therefore an adequate tracer for bone calcium in most in vivo studies.

  4. Erectile Dysfunction Precedes Coronary Artery Endothelial Dysfunction in Rats Fed a High-Fat, High-Sucrose, Western Pattern Diet

    PubMed Central

    La Favor, Justin D.; Anderson, Ethan J.; Hickner, Robert C.; Wingard, Christopher J.

    2016-01-01

    Introduction It is suggested that erectile dysfunction (ED) may be an early risk factor for cardiovascular disease. Aim The goal of this study was to determine whether development of ED precedes the onset of coronary artery endothelial dysfunction in response to a Western diet (WD), thereby establishing whether the WD differentially impacts the endothelium in a time-dependent manner. Additionally, a goal was to determine if diet-induced ED is reversible with intracavernosal sepiapterin treatment. Methods Male Sprague-Dawley rats were fed a WD for 4, 8, or 12 weeks, or a control diet for 8 weeks. Erectile function was evaluated by measuring the mean arterial pressure (MAP) and intracavernosal pressure (ICP) in response to electrical field stimulation of the cavernosal nerve near the major pelvic ganglion, in the absence and presence of sepiapterin. Coronary artery endothelial function was evaluated ex vivo with cumulative doses of acetylcholine (ACh) applied to segments of the left anterior descending coronary artery preconstricted with serotonin. Main Outcome Measures Erectile function was assessed as the ICP response to electrical field stimulation (EFS), normalized to MAP. Coronary artery endothelial function was assessed as the effective concentration producing 50% of a maximal response (EC50) of the ACh response. Results The ICP/MAP response to EFS was significantly attenuated following both 8 and 12 weeks of the WD compared with the control diet (P < 0.05). Sepiapterin treatment augmented the ICP/MAP response in all WD groups (P < 0.05). The coronary artery EC50 of the ACh response was not different from control following 4 or 8 weeks but was significantly elevated following 12 weeks of the WD (P < 0.01). Conclusions These data suggest that erectile function is reduced prior to coronary artery endothelial function in response to the WD. Improvement of erectile function with sepiapterin in WD rats indicates that nitric oxide synthase uncoupling is a key mechanism in diet-induced ED. PMID:23170997

  5. Is There a Need for More than Three Models?

    ERIC Educational Resources Information Center

    Noventa, Stefano; Massidda, Davide; Vidotto, Giulio

    2012-01-01

    An important open issue in Functional Measurement is whether the three most important models of cognitive algebra are sufficient to describe the great majority of possible response behaviors. Generally speaking, the individual response "R" is a function of the subjective scale values "s[subscript k]" and can be imagined as a continuous manifold.…

  6. Dynamic characterization of AFM probes by laser Doppler vibrometry and stroboscopic holographic methodologies

    NASA Astrophysics Data System (ADS)

    Kuppers, J. D.; Gouverneur, I. M.; Rodgers, M. T.; Wenger, J.; Furlong, C.

    2006-08-01

    In atomic probe microscopy, micro-probes of various sizes, geometries, and materials are used to define the interface between the samples under investigation and the measuring detectors and instrumentation. Therefore, measuring resolution in atomic probe microscopy is highly dependent on the transfer function characterizing the micro-probes used. In this paper, characterization of the dynamic transfer function of specific micro-cantilever probes used in an Atomic Force Microscope (AFM) operating in the tapping mode is presented. Characterization is based on the combined application of laser Doppler vibrometry (LDV) and real-time stroboscopic optoelectronic holographic microscopy (OEHM) methodologies. LDV is used for the rapid measurement of the frequency response of the probes due to an excitation function containing multiple frequency components. Data obtained from the measured frequency response is used to identify the principal harmonics. In order to identify mode shapes corresponding to the harmonics, full-field of view OEHM is applied. This is accomplished by measurements of motion at various points on the excitation curve surrounding the identified harmonics. It is shown that the combined application of LDV and OEHM enables the high-resolution characterization of mode shapes of vibration, damping characteristics, as well as transient response of the micro-cantilever probes. Such characterization is necessary in high-resolution AFM measurements.

  7. Uncertainty Estimate for the Outdoor Calibration of Solar Pyranometers: A Metrologist Perspective

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reda, I.; Myers, D.; Stoffel, T.

    2008-12-01

    Pyranometers are used outdoors to measure solar irradiance. By design, this type of radiometer can measure the; total hemispheric (global) or diffuse (sky) irradiance when the detector is unshaded or shaded from the sun disk, respectively. These measurements are used in a variety of applications including solar energy conversion, atmospheric studies, agriculture, and materials science. Proper calibration of pyranometers is essential to ensure measurement quality. This paper describes a step-by-step method for calculating and reporting the uncertainty of the calibration, using the guidelines of the ISO 'Guide to the Expression of Uncertainty in Measurement' or GUM, that is applied tomore » the pyranometer; calibration procedures used at the National Renewable Energy Laboratory (NREL). The NREL technique; characterizes a responsivity function of a pyranometer as a function of the zenith angle, as well as reporting a single; calibration responsivity value for a zenith angle of 45 ..deg... The uncertainty analysis shows that a lower uncertainty can be achieved by using the response function of a pyranometer determined as a function of zenith angle, in lieu of just using; the average value at 45..deg... By presenting the contribution of each uncertainty source to the total uncertainty; users will be able to troubleshoot and improve their calibration process. The uncertainty analysis method can also be used to determine the uncertainty of different calibration techniques and applications, such as deriving the uncertainty of field measurements.« less

  8. Chronic pain self-management support with pain science education and exercise (COMMENCE): study protocol for a randomized controlled trial.

    PubMed

    Miller, Jordan; MacDermid, Joy C; Walton, David M; Richardson, Julie

    2015-10-14

    Previous research suggests that self-management programs for people with chronic pain improve knowledge and self-efficacy but result in negligible effects on function. This study will investigate the effectiveness self-management support with pain science education and exercise on improving function for people with chronic pain in comparison to a wait-list control. A secondary objective is to determine which variables help to predict response to the intervention. This study will be an unblinded, randomized controlled trial with 110 participants comparing a 6-week program that includes self-management support, pain science education and exercise to a wait-list control. The primary outcome will be function measured by the Short Musculoskeletal Function Assessment - Dysfunction Index. Secondary outcomes will include pain intensity measured by a numeric pain rating scale, pain interference measured by the eight-item PROMIS pain interference item-bank, how much patients are bothered by functional problems measured by the Short Musculoskeletal Function Assessment - Bother Index, catastrophic thinking measured by the Pain Catastrophizing Scale, fear of movement/re-injury measured by the 11-item Tampa Scale of Kinesiophobia, sense of perceived injustice measured by the Injustice Experience Questionnaire, self-efficacy measured by the Pain Self-Efficacy Questionnaire, pain sensitivity measured by pressure pain threshold and cold sensitivity testing, fatigue measured by a numeric fatigue rating scale, pain neurophysiology knowledge measured by the Neurophysiology of Pain Questionnaire, healthcare utilization measured by number of visits to a healthcare provider, and work status. Assessments will be completed at baseline, 7 and 18 weeks. After the 18-week assessment, the groups will crossover; however, we anticipate carry-over effects with the treatment. Therefore, data from after the crossover will be used to estimate within-group changes and to determine predictors of response that are not for direct between-group comparisons. Mixed effects modelling will be used to determine between-group differences for all primary and secondary outcomes. A series of multiple regression models will be used to determine predictors of treatment response. This study has the potential to inform future self-management programming through evaluation of a self-management program that aims to improve function as the primary outcome. ClinicalTrials.gov NCT02422459 , registered on 13 April 2015.

  9. Effects of alcoholism severity and smoking on executive neurocognitive function.

    PubMed

    Glass, Jennifer M; Buu, Anne; Adams, Kenneth M; Nigg, Joel T; Puttler, Leon I; Jester, Jennifer M; Zucker, Robert A

    2009-01-01

    Neurocognitive deficits in chronic alcoholic men are well documented. Impairments include memory, visual-spatial processing, problem solving and executive function. The cause of impairment could include direct effects of alcohol toxicity, pre-existing cognitive deficits that predispose towards substance abuse, comorbid psychiatric disorders and abuse of substances other than alcohol. Cigarette smoking occurs at higher rates in alcoholism and has been linked to poor cognitive performance, yet the effects of smoking on cognitive function in alcoholism are often ignored. We examined whether chronic alcoholism and chronic smoking have effects on executive function. Alcoholism and smoking were examined in a community-recruited sample of alcoholic and non-alcoholic men (n = 240) using standard neuropsychological and reaction-time measures of executive function. Alcoholism was measured as the average level of alcoholism diagnoses across the study duration (12 years). Smoking was measured in pack-years. Both alcoholism and smoking were correlated negatively with a composite executive function score. For component measures, alcoholism was correlated negatively with a broad range of measures, whereas smoking was correlated negatively with measures that emphasize response speed. In regression analyses, both smoking and alcoholism were significant predictors of executive function composite. However, when IQ is included in the regression analyses, alcoholism severity is no longer significant. Both smoking and alcoholism were related to executive function. However, the effect of alcoholism was not independent of IQ, suggesting a generalized effect, perhaps affecting a wide range of cognitive abilities of which executive function is a component. On the other hand, the effect of smoking on measures relying on response speed were independent of IQ, suggesting a more specific processing speed deficit associated with chronic smoking.

  10. Evaluation of DNA Repair Function as a Predictor of Response in a Clinical Trial of PARP Inhibitor Monotherapy for Recurrent Ovarian Carcinoma

    DTIC Science & Technology

    2016-12-01

    no specifi c biomarkers were tested in a trial of a PARP inhibitor in patients with ovarian carcinoma with measurable disease . There is currently no... disease that was measurable with the Response Evaluation Criteria In Solid Tumors version 1.1 (RECIST) and amenable to biopsy at trial entry. Patients...have measurable disease treated with a PARP inhibitor, thereby testing the assay as a biomarker for PARP inhibitor response. Other prospective

  11. Brain Responses to Emotional Images Related to Cognitive Ability in Older Adults

    PubMed Central

    Foster, Shannon M.; Davis, Hasker P.; Kisley, Michael A.

    2013-01-01

    Older adults have been shown to exhibit a positivity effect in processing of emotional stimuli, seemingly focusing more on positive than negative information. Whether this reflects purposeful changes or an unintended side-effect of declining cognitive abilities is unclear. For the present study older adults displaying a wide range of cognitive abilities completed measures of attention, visual and verbal memory, executive functioning, and processing speed, as well as a socioemotional measure of time perspective. Regression analyses examined the ability of these variables to predict neural responsivity to select emotional stimuli as measured with the late positive potential (LPP), an event-related brain potential (ERP). Stronger cognitive functioning was associated with higher LPP amplitude in response to negative images (i.e., greater processing). This does not support a voluntary avoidance of negative information processing in older adults for this particular measure of attentional allocation. A model is proposed to reconcile this finding with the extant literature that has demonstrated positivity effects in measures of later, controlled attentional allocation. PMID:23276213

  12. Ramsay-Curve Differential Item Functioning

    ERIC Educational Resources Information Center

    Woods, Carol M.

    2011-01-01

    Differential item functioning (DIF) occurs when an item on a test, questionnaire, or interview has different measurement properties for one group of people versus another, irrespective of true group-mean differences on the constructs being measured. This article is focused on item response theory based likelihood ratio testing for DIF (IRT-LR or…

  13. Comparing Individual Differences in Inconsistency and Plasticity as Predictors of Cognitive Function in Older Adults

    PubMed Central

    Grand, Jacob H.G.; Stawski, Robert S.; MacDonald, Stuart W.S.

    2016-01-01

    Introduction Recent theorizing differentiates key constraints on cognition, including one’s current range of processing efficiency (i.e., flexibility or inconsistency) as well as the capacity to expand flexibility over time (i.e., plasticity). The present study uses intensive assessment of response time data to examine the interplay between markers of intraindividual variability (inconsistency) and gains across biweekly retest sessions (plasticity) in relation to age-related cognitive function. Method Participants included 304 adults (aged 64 to 92 years: M=74.02, SD=5.95) from Project MIND, a longitudinal burst design study assessing performance across micro and macro intervals (response latency trials, weekly bursts, annual retests). For two reaction time measures (choice RT and one-back choice RT), baseline measures of response time (RT) inconsistency (intraindividual standard deviation (ISD) across-trials at the first testing session) and plasticity (within-person performance gains in average RT across the 5 biweekly burst sessions) were computed, and then employed in linear mixed models as predictors of individual differences in cognitive function and longitudinal (6 year) rates of cognitive change. Results Independent of chronological age and years of education, higher RT inconsistency was associated uniformly with poorer cognitive function at baseline and with increased cognitive decline for measures of episodic memory and crystallized verbal ability. In contrast, predictive associations for plasticity were more modest for baseline cognitive function and were absent for 6-year cognitive change. Conclusions These findings underscore the potential utility of response times for articulating inconsistency and plasticity as dynamic predictors of cognitive function in older adults. PMID:26898536

  14. Objective and automated measurement of dynamic vision functions

    NASA Technical Reports Server (NTRS)

    Flom, M. C.; Adams, A. J.

    1976-01-01

    A phoria stimulus array and electro-oculographic (EOG) arrangements for measuring motor and sensory responses of subjects subjected to stress or drug conditions are described, along with experimental procedures. Heterophoria (as oculomotor function) and glare recovery time (time required for photochemical and neural recovery after exposure to a flash stimulus) are measured, in research aimed at developing automated objective measurement of dynamic vision functions. Onset of involuntary optokinetic nystagmus in subjects attempting to track moving stripes (while viewing through head-mounted binocular eyepieces) after exposure to glare serves as an objective measure of glare recovery time.

  15. Characterizing neurocognitive late effects in childhood leukemia survivors using a combination of neuropsychological and cognitive neuroscience measures.

    PubMed

    Van Der Plas, Ellen; Erdman, Lauren; Nieman, Brian J; Weksberg, Rosanna; Butcher, Darci T; O'connor, Deborah L; Aufreiter, Susanne; Hitzler, Johann; Guger, Sharon L; Schachar, Russell J; Ito, Shinya; Spiegler, Brenda J

    2017-10-10

    Knowledge about cognitive late effects in survivors of childhood acute lymphoblastic leukemia (ALL) is largely based on standardized neuropsychological measures and parent reports. To examine whether cognitive neuroscience paradigms provided additional insights into neurocognitive and behavioral late effects in ALL survivors, we assessed cognition and behavior using a selection of cognitive neuroscience tasks and standardized measures probing domains previously demonstrated to be affected by chemotherapy. 130 ALL survivors and 158 control subjects, between 8 and 18 years old at time of testing, completed the n-back (working memory) and stop-signal (response inhibition) tasks. ALL survivors also completed standardized measures of intelligence (Wechsler Intelligence Scales [WISC-IV]), motor skills (Grooved Pegboard), math abilities (WIAT-III), and executive functions (Delis-Kaplan Executive Function System). Parents completed behavioral measures of executive functions (Behavior Rating Inventory of Executive Function [BRIEF]) and attention (Conners-3). ALL survivors exhibited deficiencies in working memory and response inhibition compared with controls. ALL survivors also exhibited deficits on WISC-IV working memory and processing speed, Grooved Pegboard, WIAT-III addition and subtraction fluency, and numerical operations, as well as DKEFS number-letter switching. Parent reports suggested more attention deficits (Conners-3) and behavioral difficulties (BRIEF) in ALL survivors compared with referenced norms. Low correspondence between standardized and experimental measures of working memory and response inhibition was noted. The use of cognitive neuroscience paradigms complements our understanding of the cognitive deficits evident after treatment of ALL. These measures could further delineate cognitive processes involved in neurocognitive late effects, providing opportunities to explore their underlying mechanisms.

  16. A spherical harmonic approach for the determination of HCP texture from ultrasound: A solution to the inverse problem

    NASA Astrophysics Data System (ADS)

    Lan, Bo; Lowe, Michael J. S.; Dunne, Fionn P. E.

    2015-10-01

    A new spherical convolution approach has been presented which couples HCP single crystal wave speed (the kernel function) with polycrystal c-axis pole distribution function to give the resultant polycrystal wave speed response. The three functions have been expressed as spherical harmonic expansions thus enabling application of the de-convolution technique to enable any one of the three to be determined from knowledge of the other two. Hence, the forward problem of determination of polycrystal wave speed from knowledge of single crystal wave speed response and the polycrystal pole distribution has been solved for a broad range of experimentally representative HCP polycrystal textures. The technique provides near-perfect representation of the sensitivity of wave speed to polycrystal texture as well as quantitative prediction of polycrystal wave speed. More importantly, a solution to the inverse problem is presented in which texture, as a c-axis distribution function, is determined from knowledge of the kernel function and the polycrystal wave speed response. It has also been explained why it has been widely reported in the literature that only texture coefficients up to 4th degree may be obtained from ultrasonic measurements. Finally, the de-convolution approach presented provides the potential for the measurement of polycrystal texture from ultrasonic wave speed measurements.

  17. Electrodermal responses during appetitive conditioning are sensitive to contingency instruction ambiguity.

    PubMed

    van den Akker, Karolien; Nederkoorn, Chantal; Jansen, Anita

    2017-08-01

    Studies on human appetitive conditioning using food rewards can benefit from including psychophysiological outcome measures. The present study tested whether the skin conductance response can function as a measure of differential responding in an appetitive conditioning paradigm including an acquisition and extinction phase, and examined which time window during a trial is most sensitive to conditioning effects. As a secondary aim, the effects of ambiguous vs. non-ambiguous contingency instructions on conditioned responses (skin conductance responses, US expectancies, chocolate desires, and CS evaluations) were assessed. Results indicated differential skin conductance responses in an anticipatory time window and during unexpected omission of the US in early extinction. Interestingly however, anticipatory responses were only found for participants who received ambiguous contingency instructions - possibly indicating a call for additional processing resources in response to the ambiguous CS+. Further, ambiguous instructions slowed the extinction of US expectancies but did not influence chocolate desires and CS evaluations. It is concluded that skin conductance can function as a sensitive measure of differential responding in appetitive conditioning, though its sensitivity might depend on the specific task context. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Child pain catastrophizing mediates the relation between parent responses to pain and disability in youth with functional abdominal pain.

    PubMed

    Cunningham, Natoshia R; Lynch-Jordan, Anne; Barnett, Kimberly; Peugh, James; Sil, Soumitri; Goldschneider, Kenneth; Kashikar-Zuck, Susmita

    2014-12-01

    Functional abdominal pain (FAP) in youth is associated with substantial impairment in functioning, and prior research has shown that overprotective parent responses can heighten impairment. Little is known about how a range of parental behaviors (overprotection, minimizing, and/or encouragement) in response to their child's pain interact with child coping characteristics (eg, catastrophizing) to influence functioning in youth with FAP. In this study, it was hypothesized that the relation between parenting factors and child disability would be mediated by children's levels of maladaptive coping (ie, pain catastrophizing). Seventy-five patients with FAP presenting to a pediatric pain clinic and their caregivers participated in the study. Youth completed measures of pain intensity (Numeric Rating Scale), pain catastrophizing (Pain Catastrophizing Scale), and disability (Functional Disability Inventory). Caregivers completed measures of parent pain catastrophizing (Pain Catastrophizing Scale), and parent responses to child pain behaviors (Adult Responses to Child Symptoms: Protection, Minimizing, and Encouragement/Monitoring subscales). Increased functional disability was significantly related to higher child pain intensity, increased child and parent pain catastrophizing, and higher levels of encouragement/monitoring and protection. Parent minimization was not related to disability. Child pain catastrophizing fully mediated the relation between parent encouragement/monitoring and disability and partially mediated the relation between parent protectiveness and disability. The impact of parenting behaviors in response to FAP on child disability is determined, in part, by the child's coping style. Findings highlight a more nuanced understanding of the parent-child interaction in determining pain-related disability levels, which should be taken into consideration in assessing and treating youth with FAP.

  19. Using Data Augmentation and Markov Chain Monte Carlo for the Estimation of Unfolding Response Models

    ERIC Educational Resources Information Center

    Johnson, Matthew S.; Junker, Brian W.

    2003-01-01

    Unfolding response models, a class of item response theory (IRT) models that assume a unimodal item response function (IRF), are often used for the measurement of attitudes. Verhelst and Verstralen (1993)and Andrich and Luo (1993) independently developed unfolding response models by relating the observed responses to a more common monotone IRT…

  20. Development of a music therapy assessment tool for patients in low awareness states.

    PubMed

    Magee, Wendy L

    2007-01-01

    People in low awareness states following profound brain injury typically demonstrate subtle changes in functional behaviors which challenge the sensitivity of measurement tools. Failure to identify and measure changes in functioning can lead to misdiagnosis and withdrawal of treatment with this population. Thus, the development of tools which are sensitive to responsiveness is of central concern. As the auditory modality has been found to be particularly sensitive in identifying responses indicating awareness, a convincing case can be made for music therapy as a treatment medium. However, little has been recommended about protocols for intervention or tools for measuring patient responses within the music therapy setting. This paper presents the rationale for an assessment tool specifically designed to measure responses in the music therapy setting with patients who are diagnosed as minimally conscious or in a vegetative state. Developed over fourteen years as part of interdisciplinary assessment and treatment, the music therapy assessment tool for low awareness states (MATLAS) contains fourteen items which rate behavioral responses across a number of domains. The tool can provide important information for interdisciplinary assessment and treatment particularly in the auditory and communication domains. Recommendations are made for testing its reliability and validity through research.

  1. Structural stability of nonlinear population dynamics.

    PubMed

    Cenci, Simone; Saavedra, Serguei

    2018-01-01

    In population dynamics, the concept of structural stability has been used to quantify the tolerance of a system to environmental perturbations. Yet, measuring the structural stability of nonlinear dynamical systems remains a challenging task. Focusing on the classic Lotka-Volterra dynamics, because of the linearity of the functional response, it has been possible to measure the conditions compatible with a structurally stable system. However, the functional response of biological communities is not always well approximated by deterministic linear functions. Thus, it is unclear the extent to which this linear approach can be generalized to other population dynamics models. Here, we show that the same approach used to investigate the classic Lotka-Volterra dynamics, which is called the structural approach, can be applied to a much larger class of nonlinear models. This class covers a large number of nonlinear functional responses that have been intensively investigated both theoretically and experimentally. We also investigate the applicability of the structural approach to stochastic dynamical systems and we provide a measure of structural stability for finite populations. Overall, we show that the structural approach can provide reliable and tractable information about the qualitative behavior of many nonlinear dynamical systems.

  2. Structural stability of nonlinear population dynamics

    NASA Astrophysics Data System (ADS)

    Cenci, Simone; Saavedra, Serguei

    2018-01-01

    In population dynamics, the concept of structural stability has been used to quantify the tolerance of a system to environmental perturbations. Yet, measuring the structural stability of nonlinear dynamical systems remains a challenging task. Focusing on the classic Lotka-Volterra dynamics, because of the linearity of the functional response, it has been possible to measure the conditions compatible with a structurally stable system. However, the functional response of biological communities is not always well approximated by deterministic linear functions. Thus, it is unclear the extent to which this linear approach can be generalized to other population dynamics models. Here, we show that the same approach used to investigate the classic Lotka-Volterra dynamics, which is called the structural approach, can be applied to a much larger class of nonlinear models. This class covers a large number of nonlinear functional responses that have been intensively investigated both theoretically and experimentally. We also investigate the applicability of the structural approach to stochastic dynamical systems and we provide a measure of structural stability for finite populations. Overall, we show that the structural approach can provide reliable and tractable information about the qualitative behavior of many nonlinear dynamical systems.

  3. Selecting cockpit functions for speech I/O technology

    NASA Technical Reports Server (NTRS)

    Simpson, C. A.

    1985-01-01

    A general methodology for the initial selection of functions for speech generation and speech recognition technology is discussed. The SCR (Stimulus/Central-Processing/Response) compatibility model of Wickens et al. (1983) is examined, and its application is demonstrated for a particular cockpit display problem. Some limits of the applicability of that model are illustrated in the context of predicting overall pilot-aircraft system performance. A program of system performance measurement is recommended for the evaluation of candidate systems. It is suggested that no one measure of system performance can necessarily be depended upon to the exclusion of others. Systems response time, system accuracy, and pilot ratings are all important measures. Finally, these measures must be collected in the context of the total flight task environment.

  4. Temporal resolution of the Florida manatee (Trichechus manatus latirostris) auditory system.

    PubMed

    Mann, David A; Colbert, Debborah E; Gaspard, Joseph C; Casper, Brandon M; Cook, Mandy L H; Reep, Roger L; Bauer, Gordon B

    2005-10-01

    Auditory evoked potential (AEP) measurements of two Florida manatees (Trichechus manatus latirostris) were measured in response to amplitude modulated tones. The AEP measurements showed weak responses to test stimuli from 4 kHz to 40 kHz. The manatee modulation rate transfer function (MRTF) is maximally sensitive to 150 and 600 Hz amplitude modulation (AM) rates. The 600 Hz AM rate is midway between the AM sensitivities of terrestrial mammals (chinchillas, gerbils, and humans) (80-150 Hz) and dolphins (1,000-1,200 Hz). Audiograms estimated from the input-output functions of the EPs greatly underestimate behavioral hearing thresholds measured in two other manatees. This underestimation is probably due to the electrodes being located several centimeters from the brain.

  5. Caregiver Appraisals of Functional Dependence in Individuals With Dementia and Associated Caregiver Upset: Psychometric Properties of a New Scale and Response Patterns by Caregiver and Care Recipient Characteristics

    PubMed Central

    GITLIN, LAURA N.; ROTH, DAVID L.; BURGIO, LOUIS D.; LOEWENSTEIN, DAVID A.; WINTER, LARAINE; NICHOLS, LINDA; ARGÜELLES, SOLEDAD; CORCORAN, MARY; BURNS, ROBERT; MARTINDALE, JENNIFER

    2008-01-01

    Objective To evaluate psychometric properties and response patterns of the Caregiver Assessment of Function and Upset (CAFU), a 15-item multidimensional measure of dependence in dementia patients and caregiver reaction. Method 640 families were administered the CAFU (53% White, 43% African American, and 4% mixed race and ethnicity). We created a random split of the sample and conducted exploratory factor analyses on Sample 1 and confirmatory factor analyses on Sample 2. Convergent and discriminant validity were evaluated using Spearman rank correlation coefficients. Results A two-factor structure for functional items was derived, and excellent factorial validity was obtained. Convergent and discriminant validity were obtained for function and upset measures. Differential response patterns for dependence and caregiver upset were found for caregiver race, relationship, and care recipient gender but not for caregiver gender. Discussion The CAFU is easily administered, reliable, and valid for evaluating appraisals of dependencies and upsetting care areas. PMID:15750049

  6. [Quenched fluorescein: a reference dye for instrument response function of TCSPC].

    PubMed

    Pan, Hai-feng; Ding, Jing-xin; Liang, Rong-rong; Tao, Zhan-dong; Liu, Meng-wei; Zhang, San-jun; Xu, Jian-hua

    2014-08-01

    Measuring the instrument response function (IRF) and fitting by reconvolution algorithms are routines to improve time resolution in fluorescence lifetime measurements. Iodide ions were successfully used to quench the fluorescence of fluorescein in this study. By systematically adding saturated NaI water solution in basic fluorescein solution, the lifetimes of fluorescein were reduced from 4 ns to 24 ps. The quenched lifetime of fluorescein obtained from the analysis of Time-Correlated Single Photon Counting (TCSPC) measurement agrees well with that from femtosecond frequency up-conversion measurement. In time resolved excitation spectra measurements, the IRF should be measured at various detection wavelengths providing scattring materials are used. This study could not only reduce the complexity of IRF measurement, but also avoid the existing color effect in system. This study should have wide applications in time resolved fluorescence spectroscopy and fluorescence lifetime imaging.

  7. Readability and Comprehension of the Geriatric Depression Scale and PROMIS® Physical Function Items in Older African Americans and Latinos.

    PubMed

    Paz, Sylvia H; Jones, Loretta; Calderón, José L; Hays, Ron D

    2017-02-01

    Depression and physical function are particularly important health domains for the elderly. The Geriatric Depression Scale (GDS) and the Patient-Reported Outcomes Measurement Information System (PROMIS ® ) physical function item bank are two surveys commonly used to measure these domains. It is unclear if these two instruments adequately measure these aspects of health in minority elderly. The aim of this study was to estimate the readability of the GDS and PROMIS ® physical function items and to assess their comprehensibility using a sample of African American and Latino elderly. Readability was estimated using the Flesch-Kincaid and Flesch Reading Ease (FRE) formulae for English versions, and a Spanish adaptation of the FRE formula for the Spanish versions. Comprehension of the GDS and PROMIS ® items by minority elderly was evaluated with 30 cognitive interviews. Readability estimates of a number of items in English and Spanish of the GDS and PROMIS ® physical functioning items exceed the U.S. recommended 5th-grade threshold for vulnerable populations, or were rated as 'fairly difficult', 'difficult', or 'very difficult' to read. Cognitive interviews revealed that many participants felt that more than the two (yes/no) GDS response options were needed to answer the questions. Wording of several PROMIS ® items was considered confusing, and interpreting responses was problematic because they were based on using physical aids. Problems with item wording and response options of the GDS and PROMIS ® physical function items may reduce reliability and validity of measurement when used with minority elderly.

  8. Procedures to develop a computerized adaptive test to assess patient-reported physical functioning.

    PubMed

    McCabe, Erin; Gross, Douglas P; Bulut, Okan

    2018-06-07

    The purpose of this paper is to demonstrate the procedures to develop and implement a computerized adaptive patient-reported outcome (PRO) measure using secondary analysis of a dataset and items from fixed-format legacy measures. We conducted secondary analysis of a dataset of responses from 1429 persons with work-related lower extremity impairment. We calibrated three measures of physical functioning on the same metric, based on item response theory (IRT). We evaluated efficiency and measurement precision of various computerized adaptive test (CAT) designs using computer simulations. IRT and confirmatory factor analyses support combining the items from the three scales for a CAT item bank of 31 items. The item parameters for IRT were calculated using the generalized partial credit model. CAT simulations show that reducing the test length from the full 31 items to a maximum test length of 8 items, or 20 items is possible without a significant loss of information (95, 99% correlation with legacy measure scores). We demonstrated feasibility and efficiency of using CAT for PRO measurement of physical functioning. The procedures we outlined are straightforward, and can be applied to other PRO measures. Additionally, we have included all the information necessary to implement the CAT of physical functioning in the electronic supplementary material of this paper.

  9. The development of regulatory functions from birth to 5 years: insights from premature infants.

    PubMed

    Feldman, Ruth

    2009-01-01

    This study examined physiological, emotional, and attentional regulatory functions as predictors of self-regulation in 125 infants followed 7 times from birth to 5 years. Physiological regulation was assessed by neonatal vagal tone and sleep-wake cyclicity; emotion regulation by response to stress at 3, 6, and 12 months; and attention regulation by focused attention and delayed response in the 2nd year. Executive functions, behavior adaptation, and self-restraint were measured at 5 years. Regulatory functions showed stability across time, measures, and levels. Structural modeling demonstrated both mediated paths from physiological to self-regulation through emotional and attentional processes and direct continuity between vagal tone and each level of regulation. Results support the coherence of the regulation construct and are consistent with neurobiological models on self and consciousness.

  10. Preserved MHC-II antigen processing and presentation function in chronic HCV infection

    PubMed Central

    DH, Canaday; CJ, Burant; L, Jones; H, Aung; L, Woc-Colburn; DD, Anthony

    2010-01-01

    Individuals with chronic HCV infection have impaired response to vaccine, though the etiology remains to be elucidated. Dendritic cells (DC) and monocytes (MN) provide antigen uptake, processing, presentation, and costimulatory functions necessary to achieve optimal immune responses. The integrity of antigen processing and presentation function within these antigen presenting cells (APC) in the setting of HCV infection has been unclear. We used a novel T cell hybridoma system that specifically measures MHC-II antigen processing and presentation function of human APC. Results demonstrate MHC-II antigen processing and presentation function is preserved in both myeloid DC (mDC) and MN in the peripheral blood of chronically HCV-infected individuals, and indicates that an alteration in this function does not likely underlie the defective HCV-infected host response to vaccination. PMID:21055734

  11. Executive functioning complaints and escitalopram treatment response in late-life depression.

    PubMed

    Manning, Kevin J; Alexopoulos, George S; Banerjee, Samprit; Morimoto, Sarah Shizuko; Seirup, Joanna K; Klimstra, Sibel A; Yuen, Genevieve; Kanellopoulos, Theodora; Gunning-Dixon, Faith

    2015-05-01

    Executive dysfunction may play a key role in the pathophysiology of late-life depression. Executive dysfunction can be assessed with cognitive tests and subjective report of difficulties with executive skills. The present study investigated the association between subjective report of executive functioning complaints and time to escitalopram treatment response in older adults with major depressive disorder (MDD). 100 older adults with MDD (58 with executive functioning complaints and 42 without executive functioning complaints) completed a 12-week trial of escitalopram. Treatment response over 12 weeks, as measured by repeated Hamilton Depression Rating Scale scores, was compared for adults with and without executive complaints using mixed-effects modeling. Mixed effects analysis revealed a significant group × time interaction, F(1, 523.34) = 6.00, p = 0.01. Depressed older adults who reported executive functioning complaints at baseline demonstrated a slower response to escitalopram treatment than those without executive functioning complaints. Self-report of executive functioning difficulties may be a useful prognostic indicator for subsequent speed of response to antidepressant medication. Copyright © 2015 American Association for Geriatric Psychiatry. Published by Elsevier Inc. All rights reserved.

  12. Identification of measurement differences between English and Spanish language versions of the Mini-Mental State Examination. Detecting differential item functioning using MIMIC modeling.

    PubMed

    Jones, Richard N

    2006-11-01

    Knowledge of the extent to which measurement of adult cognitive functioning differs between Spanish and English language administrations of the Mini-Mental State Examination (MMSE) is critical for inclusive, representative, and valid research of older adults in the United States. We sought to demonstrate the use of an item response theory (IRT) based structural equation model, that is, the MIMIC model (multiple indicators, multiple causes), to evaluate MMSE responses for evidence of differential item functioning (DIF) attributable to language of administration. We studied participants in a dementia case registry study (n = 1546), 42% of whom were examined with the Spanish language MMSE. Twelve of 21 items were identified as having significant uniform DIF. The 4 most discrepant included orientation to season, orientation to state, repeat phrase, and follow command. DIF accounted for two-thirds of the observed difference in underlying level of cognitive functioning between Spanish- and English-language administration groups. Failing to account for measurement differences may lead to spurious inferences regarding language group differences in level of underlying level of cognitive functioning. The MIMIC model can be used to detect and adjust for such measurement differences in substantive research.

  13. Opposing Responses of Bird Functional Diversity to Vegetation Structural Diversity in Wet and Dry Forest.

    PubMed

    Sitters, Holly; York, Alan; Swan, Matthew; Christie, Fiona; Di Stefano, Julian

    2016-01-01

    Disturbance regimes are changing worldwide, and the consequences for ecosystem function and resilience are largely unknown. Functional diversity (FD) provides a surrogate measure of ecosystem function by capturing the range, abundance and distribution of trait values in a community. Enhanced understanding of the responses of FD to measures of vegetation structure at landscape scales is needed to guide conservation management. To address this knowledge gap, we used a whole-of-landscape sampling approach to examine relationships between bird FD, vegetation diversity and time since fire. We surveyed birds and measured vegetation at 36 landscape sampling units in dry and wet forest in southeast Australia during 2010 and 2011. Four uncorrelated indices of bird FD (richness, evenness, divergence and dispersion) were derived from six bird traits, and we investigated responses of these indices and species richness to both vertical and horizontal vegetation diversity using linear mixed models. We also considered the extent to which the mean and diversity of time since fire were related to vegetation diversity. Results showed opposing responses of FD to vegetation diversity in dry and wet forest. In dry forest, where fire is frequent, species richness and two FD indices (richness and dispersion) were positively related to vertical vegetation diversity, consistent with theory relating to environmental variation and coexistence. However, in wet forest subject to infrequent fire, the same three response variables were negatively associated with vertical diversity. We suggest that competitive dominance by species results in lower FD as vegetation diversity increases in wet forest. The responses of functional evenness were opposite to those of species richness, functional richness and dispersion in both forest types, highlighting the value of examining multiple FD metrics at management-relevant scales. The mean and diversity of time since fire were uncorrelated with vegetation diversity in wet forest, but positively correlated with vegetation diversity in dry forest. We therefore suggest that protection of older vegetation is important, but controlled application of low-severity fire in dry forest may sustain ecosystem function by enhancing different elements of FD.

  14. Opposing Responses of Bird Functional Diversity to Vegetation Structural Diversity in Wet and Dry Forest

    PubMed Central

    York, Alan; Swan, Matthew; Christie, Fiona; Di Stefano, Julian

    2016-01-01

    Disturbance regimes are changing worldwide, and the consequences for ecosystem function and resilience are largely unknown. Functional diversity (FD) provides a surrogate measure of ecosystem function by capturing the range, abundance and distribution of trait values in a community. Enhanced understanding of the responses of FD to measures of vegetation structure at landscape scales is needed to guide conservation management. To address this knowledge gap, we used a whole-of-landscape sampling approach to examine relationships between bird FD, vegetation diversity and time since fire. We surveyed birds and measured vegetation at 36 landscape sampling units in dry and wet forest in southeast Australia during 2010 and 2011. Four uncorrelated indices of bird FD (richness, evenness, divergence and dispersion) were derived from six bird traits, and we investigated responses of these indices and species richness to both vertical and horizontal vegetation diversity using linear mixed models. We also considered the extent to which the mean and diversity of time since fire were related to vegetation diversity. Results showed opposing responses of FD to vegetation diversity in dry and wet forest. In dry forest, where fire is frequent, species richness and two FD indices (richness and dispersion) were positively related to vertical vegetation diversity, consistent with theory relating to environmental variation and coexistence. However, in wet forest subject to infrequent fire, the same three response variables were negatively associated with vertical diversity. We suggest that competitive dominance by species results in lower FD as vegetation diversity increases in wet forest. The responses of functional evenness were opposite to those of species richness, functional richness and dispersion in both forest types, highlighting the value of examining multiple FD metrics at management-relevant scales. The mean and diversity of time since fire were uncorrelated with vegetation diversity in wet forest, but positively correlated with vegetation diversity in dry forest. We therefore suggest that protection of older vegetation is important, but controlled application of low-severity fire in dry forest may sustain ecosystem function by enhancing different elements of FD. PMID:27741290

  15. Effect of heavy metals on nitrification activity as measured by RNA- and DNA-based function-specific assays

    EPA Science Inventory

    Heavy metals can inhibit nitrification, a key process for nitrogen removal in wastewater treatment. The transcriptional responses of functional genes (amoA, hao, nirK and norB) were measured in conjunction with specific oxygen uptake rate (sOUR) for nitrifying enrichment cultures...

  16. A Comparison of Lord's Chi Square and Raju's Area Measures in Detection of DIF.

    ERIC Educational Resources Information Center

    Cohen, Allan S.; Kim, Seock-Ho

    1993-01-01

    The effectiveness of two statistical tests of the area between item response functions (exact signed area and exact unsigned area) estimated in different samples, a measure of differential item functioning (DIF), was compared with Lord's chi square. Lord's chi square was found the most effective in determining DIF. (SLD)

  17. An introduction to Item Response Theory and Rasch Analysis of the Eating Assessment Tool (EAT-10).

    PubMed

    Kean, Jacob; Brodke, Darrel S; Biber, Joshua; Gross, Paul

    2018-03-01

    Item response theory has its origins in educational measurement and is now commonly applied in health-related measurement of latent traits, such as function and symptoms. This application is due in large part to gains in the precision of measurement attributable to item response theory and corresponding decreases in response burden, study costs, and study duration. The purpose of this paper is twofold: introduce basic concepts of item response theory and demonstrate this analytic approach in a worked example, a Rasch model (1PL) analysis of the Eating Assessment Tool (EAT-10), a commonly used measure for oropharyngeal dysphagia. The results of the analysis were largely concordant with previous studies of the EAT-10 and illustrate for brain impairment clinicians and researchers how IRT analysis can yield greater precision of measurement.

  18. Nuclear Cytoplasmic Trafficking of Proteins is a Major Response of Human Fibroblasts to Oxidative Stress

    PubMed Central

    Baqader, Noor O.; Radulovic, Marko; Crawford, Mark; Stoeber, Kai; Godovac-Zimmermann, Jasminka

    2014-01-01

    We have used a subcellular spatial razor approach based on LC–MS/MS-based proteomics with SILAC isotope labeling to determine changes in protein abundances in the nuclear and cytoplasmic compartments of human IMR90 fibroblasts subjected to mild oxidative stress. We show that response to mild tert-butyl hydrogen peroxide treatment includes redistribution between the nucleus and cytoplasm of numerous proteins not previously associated with oxidative stress. The 121 proteins with the most significant changes encompass proteins with known functions in a wide variety of subcellular locations and of cellular functional processes (transcription, signal transduction, autophagy, iron metabolism, TCA cycle, ATP synthesis) and are consistent with functional networks that are spatially dispersed across the cell. Both nuclear respiratory factor 2 and the proline regulatory axis appear to contribute to the cellular metabolic response. Proteins involved in iron metabolism or with iron/heme as a cofactor as well as mitochondrial proteins are prominent in the response. Evidence suggesting that nuclear import/export and vesicle-mediated protein transport contribute to the cellular response was obtained. We suggest that measurements of global changes in total cellular protein abundances need to be complemented with measurements of the dynamic subcellular spatial redistribution of proteins to obtain comprehensive pictures of cellular function. PMID:25133973

  19. Restoring function in major depressive disorder: A systematic review.

    PubMed

    Sheehan, David V; Nakagome, Kazuyuki; Asami, Yuko; Pappadopulos, Elizabeth A; Boucher, Matthieu

    2017-06-01

    Functional impairment contributes to significant disability and economic burden in major depressive disorder (MDD). Treatment response is measured by improvement in depressive symptoms, but functional improvement often lags behind symptomatic improvement. Residual deficits are associated with relapse of depressive symptoms. A literature search was conducted using the following terms: "major depressive disorder," "functional impairment," "functional outcomes," "recovery of function," "treatment outcome," "outcome assessment," "social functioning," "presenteeism," "absenteeism," "psychiatric status rating scales," and "quality of life." Search limits included publication date (January 1, 1995 to August 31, 2016), English language, and human clinical trials. Controlled, acute-phase, nonrecurrent MDD treatment studies in adults were included if a functional outcome was measured at baseline and endpoint. The qualitative analysis included 35 controlled studies. The Sheehan Disability Scale was the most commonly used functional assessment. Antidepressant treatments significantly improved functional outcomes. Early treatment response predicted functional improvement, while baseline disease severity did not. Clinical studies utilized various methodologies and assessments for functional impairment, and were not standardized or adequately powered. The lack of synchronicity between symptomatic and functional improvement highlights an unmet need for MDD. Treatment guided by routine monitoring of symptoms and functionality may minimize residual functional impairments. Copyright © 2017. Published by Elsevier B.V.

  20. Neutron light output response and resolution functions in EJ-309 liquid scintillation detectors

    DOE PAGES

    Enqvist, Andreas; Lawrence, Christopher C.; Wieger, Brian M.; ...

    2013-03-26

    Here, the neutron light output response functions and detector resolution functions were measured at Ohio University's tandem Van de Graaff generator for three cylindrical EJ-309 liquid scintillator cells, having dimensions 12.7(circle divide)-by-12.7, 7.6-by-7.6, and 7.6-by-5.1 cm. A 7.44 MeV deuteron beam was used on an Al-27 target generating a continuous spectrum over the energy range from a few hundred keV to over 10 MeV. The light output response functions are determined using an exponential fit. Detector resolution functions are obtained for the 12.7-by-12.7 and 7.6-by-7.6 cm detectors. It is demonstrated that the dependence on detector size is important for themore » light output response functions, but not to the same extent for the resolution function, even when photomultiplier tubes, detector material, and other detector characteristics are carefully matched.« less

  1. Carbon Dioxide and Fruit Odor Transduction in Drosophila Olfactory Neurons. What Controls their Dynamic Properties?

    PubMed Central

    French, Andrew S.; Meisner, Shannon; Su, Chih-Ying; Torkkeli, Päivi H.

    2014-01-01

    We measured frequency response functions between odorants and action potentials in two types of neurons in Drosophila antennal basiconic sensilla. CO2 was used to stimulate ab1C neurons, and the fruit odor ethyl butyrate was used to stimulate ab3A neurons. We also measured frequency response functions for light-induced action potential responses from transgenic flies expressing H134R-channelrhodopsin-2 (ChR2) in the ab1C and ab3A neurons. Frequency response functions for all stimulation methods were well-fitted by a band-pass filter function with two time constants that determined the lower and upper frequency limits of the response. Low frequency time constants were the same in each type of neuron, independent of stimulus method, but varied between neuron types. High frequency time constants were significantly slower with ethyl butyrate stimulation than light or CO2 stimulation. In spite of these quantitative differences, there were strong similarities in the form and frequency ranges of all responses. Since light-activated ChR2 depolarizes neurons directly, rather than through a chemoreceptor mechanism, these data suggest that low frequency dynamic properties of Drosophila olfactory sensilla are dominated by neuron-specific ionic processes during action potential production. In contrast, high frequency dynamics are limited by processes associated with earlier steps in odor transduction, and CO2 is detected more rapidly than fruit odor. PMID:24466044

  2. Responsiveness of SF-36 and Lower Extremity Functional Scale for assessing outcomes in traumatic injuries of lower extremities.

    PubMed

    Pan, Shin-Liang; Liang, Huey-Wen; Hou, Wen-Hsuan; Yeh, Tian-Shin

    2014-11-01

    To assess the responsiveness of one generic questionnaire, Medical Outcomes Study Short Form-36 (SF-36), and one region-specific outcome measure, Lower Extremity Functional Scale (LEFS), in patients with traumatic injuries of lower extremities. A prospective and observational study of patients after traumatic injuries of lower extremities. Assessments were performed at baseline and 3 months later. In-patients and out-patients in two university hospitals in Taiwan. A convenience sample of 109 subjects were evaluated and 94 (86%) were followed. Not applicable. Assessments of responsiveness with distribution-based approach (effect size, standardized response mean [SRM], minimal detectable change) and anchor-based approach (receiver's operating curve analysis, ROC analysis). LEFS and physical component score (PCS) of SF-36 were all responsive to global improvement, with fair-to-good accuracy in discriminating between participants with and without improvement. The area under curve gained by ROC analysis for LEFS and SF-36 PCS was similar (0.65 vs. 0.70, p=0.26). Our findings revealed comparable responsiveness of LEFS and PCS of SF-36 in a sample of subjects with traumatic injuries of lower limbs. Either type of functional measure would be suitable for use in clinical trials where improvement in function was an endpoint of interest. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Matching Microscopic and Macroscopic Responses in Glasses.

    PubMed

    Baity-Jesi, M; Calore, E; Cruz, A; Fernandez, L A; Gil-Narvion, J M; Gordillo-Guerrero, A; Iñiguez, D; Maiorano, A; Marinari, E; Martin-Mayor, V; Monforte-Garcia, J; Muñoz-Sudupe, A; Navarro, D; Parisi, G; Perez-Gaviro, S; Ricci-Tersenghi, F; Ruiz-Lorenzo, J J; Schifano, S F; Seoane, B; Tarancon, A; Tripiccione, R; Yllanes, D

    2017-04-14

    We first reproduce on the Janus and Janus II computers a milestone experiment that measures the spin-glass coherence length through the lowering of free-energy barriers induced by the Zeeman effect. Secondly, we determine the scaling behavior that allows a quantitative analysis of a new experiment reported in the companion Letter [S. Guchhait and R. Orbach, Phys. Rev. Lett. 118, 157203 (2017)].PRLTAO0031-900710.1103/PhysRevLett.118.157203 The value of the coherence length estimated through the analysis of microscopic correlation functions turns out to be quantitatively consistent with its measurement through macroscopic response functions. Further, nonlinear susceptibilities, recently measured in glass-forming liquids, scale as powers of the same microscopic length.

  4. The influence of smoking on reward responsiveness and cognitive functions: a natural experiment.

    PubMed

    al-Adawi, S; Powell, J

    1997-12-01

    To investigate the effects of (a) nicotine abstinence and (b) cigarette smoking after abstinence, on reward responsiveness and cognitive functions which are putatively dependent on activity in the dopaminergic system implicated in smoking. During Ramadhan, Muslim smokers elected to abstain from smoking either for the whole month (RAMQUIT) or during daylight hours (DAYQUIT). These groups, and non-smokers (NOSMOKE), were assessed on two occasions 6 hours apart (TEST1 and TEST2). DAYQUIT participants had abstained for 6 hours at TEST1 and smoked a single cigarette immediately prior to TEST2. RAMQUIT participants had abstained for at least 10 days prior to TEST1 and remained abstinent at TEST2. NOSMOKE and RAMQUIT participants are a small snack prior to TEST2 to control for non-specific consummatory effects. TEST1 was conducted at the mosque and TEST2 in participants' homes. All were male; mean age was 26.7 years. Modal cigarette consumption prior to Ramadhan by both the 13 DAYQUIT and the 11 RAMQUIT smokers was 21-30 per day. DAYQUIT subjects rated themselves as more dependent. The Card Arranging Reward Responsivity Objective Test (CARROT), testing behavioural responsiveness to small financial incentive; digit span, measuring attention; verbal fluency, indexing frontal lobe function; and the two-choice guessing test (2CGT; at TEST1 only), measuring response stereotypy. At TEST1, compared with non-smokers, both smoking groups showed greater stereotypy (2CG) and lower reward responsiveness (CARROT). DAYQUIT participants improved on all measures after smoking a single cigarette. No marked changes were seen in the other groups. These data suggest that (i) abstaining smokers have impaired dopaminergic function and (ii) nicotine consumption may boost their dopaminergic activity.

  5. The Brighton musculoskeletal Patient-Reported Outcome Measure (BmPROM): An assessment of validity, reliability, and responsiveness.

    PubMed

    Bryant, Elizabeth; Murtagh, Shemane; Finucane, Laura; McCrum, Carol; Mercer, Christopher; Smith, Toby; Canby, Guy; Rowe, David A; Moore, Ann P

    2018-05-11

    In response for the need of a freely available, stand-alone, validated outcome measure for use within musculoskeletal (MSK) physiotherapy practice, sensitive enough to measure clinical effectiveness, we developed an MSK patient reported outcome measure. This study examined the validity and reliability of the newly developed Brighton musculoskeletal Patient-Reported Outcome Measure (BmPROM) within physiotherapy outpatient settings. Two hundred twenty-four patients attending physiotherapy outpatient departments in South East England with an MSK condition participated in this study. The BmPROM was assessed for user friendliness (rated feedback, N = 224), reliability (internal consistency and test-retest reliability, n = 42), validity (internal and external construct validity, N = 224), and responsiveness (internal, n = 25). Exploratory factor analysis indicated that a two-factor model provides a good fit to the data. Factors were representative of "Functionality" and "Wellbeing". Correlations observed between the BmPROM and SF-36 domains provided evidence of convergent validity. Reliability results indicated that both subscales were internally consistent with alphas above the acceptable limits for both "Functionality" (α = .85, 95% CI [.81, .88]) and 'Wellbeing' (α = .80, 95% CI [.75, .84]). Test-retest analyses (n = 42) demonstrated a high degree of reliability between "Functionality" (ICC = .84; 95% CI [.72, .91]) and "Wellbeing" scores (ICC = .84; 95% CI [.72, .91]). Further examination of test-retest reliability through the Bland-Altman analysis demonstrated that the difference between "Functionality" and "Wellbeing" test scores did not vary as a function of absolute test score. Large treatment effect sizes were found for both subscales (Functionality d = 1.10; Wellbeing 1.03). The BmPROM is a reliable and valid outcome measure for use in evaluating physiotherapy treatment of MSK conditions. Copyright © 2018 John Wiley & Sons, Ltd.

  6. Radiometric characterization of an LWIR, type-II strained layer superlattice pBiBn photodetector

    NASA Astrophysics Data System (ADS)

    Treider, L. A.; Morath, C. P.; Cowan, V. M.; Tian, Z. B.; Krishna, S.

    2015-05-01

    Type-II Strained Layer Superlattice (T2SLS) infrared photodetectors have been in development over the last decade. T2SLS offers a theoretically longer Auger recombination lifetime than traditional mercury cadmium telluride (MCT), which presumably translates to infrared detectors with lower dark-current and higher operating temperatures. However, these improvements did not materialize due to the presence of Shockley-Read-Hall (SRH) defects in T2SLSs, which limits the recombination lifetime well below the Auger-limit. With the recent introduction of the pBiBn, and other similar unipolar barrier detectors, T2SLS material has seen renewed interest since these designs ideally eliminate the SRH-generation and surface currents while retaining the other potential advantages of T2SLS: reduced manufacturing cost, better availability of a durable state-side manufacturing base, ability to tune the cutoff wavelength, and better uniformity. Here, an electrical and optical characterization of a long-wave, pBiBn detector with a T2SLS absorber is presented. Dark-current, spectral response and optical response were measured as functions of temperature and bias. Activation energy was then determined as a function of bias from the dark-current measurements. Quantum efficiency was also determined as a function of bias from the optical response measurements. Additionally, noise spectrum measurements were taken as a function of bias.

  7. Measurement properties of performance-based measures to assess physical function in hip and knee osteoarthritis: a systematic review.

    PubMed

    Dobson, F; Hinman, R S; Hall, M; Terwee, C B; Roos, E M; Bennell, K L

    2012-12-01

    To systematically review the measurement properties of performance-based measures to assess physical function in people with hip and/or knee osteoarthritis (OA). Electronic searches were performed in MEDLINE, CINAHL, Embase, and PsycINFO up to the end of June 2012. Two reviewers independently rated measurement properties using the consensus-based standards for the selection of health status measurement instrument (COSMIN). "Best evidence synthesis" was made using COSMIN outcomes and the quality of findings. Twenty-four out of 1792 publications were eligible for inclusion. Twenty-one performance-based measures were evaluated including 15 single-activity measures and six multi-activity measures. Measurement properties evaluated included internal consistency (three measures), reliability (16 measures), measurement error (14 measures), validity (nine measures), responsiveness (12 measures) and interpretability (three measures). A positive rating was given to only 16% of possible measurement ratings. Evidence for the majority of measurement properties of tests reported in the review has yet to be determined. On balance of the limited evidence, the 40 m self-paced test was the best rated walk test, the 30 s-chair stand test and timed up and go test were the best rated sit to stand tests, and the Stratford battery, Physical Activity Restrictions and Functional Assessment System were the best rated multi-activity measures. Further good quality research investigating measurement properties of performance measures, including responsiveness and interpretability in people with hip and/or knee OA, is needed. Consensus on which combination of measures will best assess physical function in people with hip/and or knee OA is urgently required. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  8. On the Usefulness of a Multilevel Logistic Regression Approach to Person-Fit Analysis

    ERIC Educational Resources Information Center

    Conijn, Judith M.; Emons, Wilco H. M.; van Assen, Marcel A. L. M.; Sijtsma, Klaas

    2011-01-01

    The logistic person response function (PRF) models the probability of a correct response as a function of the item locations. Reise (2000) proposed to use the slope parameter of the logistic PRF as a person-fit measure. He reformulated the logistic PRF model as a multilevel logistic regression model and estimated the PRF parameters from this…

  9. Response-time enhancement of a clinical gas analyzer facilitates measurement of breath-by-breath gas exchange.

    PubMed

    Farmery, A D; Hahn, C E

    2000-08-01

    Tidal ventilation gas-exchange models in respiratory physiology and medicine not only require solution of mass balance equations breath-by-breath but also may require within-breath measurements, which are instantaneous functions of time. This demands a degree of temporal resolution and fidelity of integration of gas flow and concentration signals that cannot be provided by most clinical gas analyzers because of their slow response times. We have characterized the step responses of the Datex Ultima (Datex Instrumentation, Helsinki, Finland) gas analyzer to oxygen, carbon dioxide, and nitrous oxide in terms of a Gompertz four-parameter sigmoidal function. By inversion of this function, we were able to reduce the rise times for all these gases almost fivefold, and, by its application to real on-line respiratory gas signals, it is possible to achieve a performance comparable to the fastest mass spectrometers. With the use of this technique, measurements required for non-steady-state and tidal gas-exchange models can be made easily and reliably in the clinical setting.

  10. Well-ionization chamber response relative to NIST air-kerma strength standard for prostate brachytherapy seeds.

    PubMed

    Mitch, M G; Zimmerman, B E; Lamperti, P J; Seltzer, S M; Coursey, B M

    2000-10-01

    The response of well-ionization chambers to the emissions of 103Pd and 125I radioactive seed sources used in prostate cancer brachytherapy has been measured. Calibration factors relating chamber response (current or dial setting) to measured air-kerma strength have been determined for seeds from nine manufacturers, each with different designs. Variations in well-ionization chamber response relative to measured air-kerma strength have been observed because of differences in the emitted energy spectrum due to both the radionuclide support material (125I seeds) and the mass ratio of 103Pd to 102Pd (103Pd seeds). Obtaining accurate results from quality assurance measurements using well-ionization chambers at a therapy clinic requires knowledge of such differences in chamber response as a function of seed design.

  11. Listen to their answers! Response behaviour in the measurement of physical and role functioning

    PubMed Central

    Hak, Tony; Sprangers, Mirjam A. G.; Groen, Harry J. M.; van der Wal, Gerrit; The, Anne-Mei

    2008-01-01

    Background Quality of life (QoL) is considered to be an indispensable outcome measure of curative and palliative treatment. However, QoL research often yields findings that raise questions about what QoL measurement instruments actually assess and how the scores should be interpreted. Objective To investigate how patients interpret and respond to questions on the EORTC-QLQ-C30 over time and to find explanations to account for counterintuitive findings in QoL measurement. Methods Qualitative investigation was made of the response behaviour of small-cell lung cancer patients (n = 23) in the measurement of QoL with the European Organization for Research and Treatment of Cancer Core Quality of Life Questionnaire (EORTC QLQ-C30). Focus was on physical functioning (PF, items 1 to 5), role functioning (RF, items 6 and 7), global health and QoL rating (GH/QOL, items 29 and 30). Interviews were held at four points: at the start of the chemotherapy, 4 weeks later, at the end, and 6 weeks after the end of chemotherapy. Patients were asked to ‘think aloud’ when filling in the questionnaire. Results Patients used various response strategies when answering questions about problems and limitations in functioning, which impacted the accuracy of the scale. Patients had scores suggesting they were less limited than they actually were by taking the wording of questions literally, by guessing their functioning in activities that they did not perform, and by ignoring or excluding certain activities that they could not perform. Conclusion Terminally ill patients evaluate their functioning in terms of what they perceive to be normal under the circumstances. Their answers can be interpreted in terms of change in the appraisal process (Rapkin and Schwartz 2004; Health and Quality of Life Outcomes, 2, 14). More care should be taken in assessing the quality of a set of questions about physical and role functioning. PMID:18389384

  12. Listen to their answers! Response behaviour in the measurement of physical and role functioning.

    PubMed

    Westerman, Marjan J; Hak, Tony; Sprangers, Mirjam A G; Groen, Harry J M; van der Wal, Gerrit; The, Anne-Mei

    2008-05-01

    Quality of life (QoL) is considered to be an indispensable outcome measure of curative and palliative treatment. However, QoL research often yields findings that raise questions about what QoL measurement instruments actually assess and how the scores should be interpreted. To investigate how patients interpret and respond to questions on the EORTC-QLQ-C30 over time and to find explanations to account for counterintuitive findings in QoL measurement. Qualitative investigation was made of the response behaviour of small-cell lung cancer patients (n = 23) in the measurement of QoL with the European Organization for Research and Treatment of Cancer Core Quality of Life Questionnaire (EORTC QLQ-C30). Focus was on physical functioning (PF, items 1 to 5), role functioning (RF, items 6 and 7), global health and QoL rating (GH/QOL, items 29 and 30). Interviews were held at four points: at the start of the chemotherapy, 4 weeks later, at the end, and 6 weeks after the end of chemotherapy. Patients were asked to 'think aloud' when filling in the questionnaire. Patients used various response strategies when answering questions about problems and limitations in functioning, which impacted the accuracy of the scale. Patients had scores suggesting they were less limited than they actually were by taking the wording of questions literally, by guessing their functioning in activities that they did not perform, and by ignoring or excluding certain activities that they could not perform. Terminally ill patients evaluate their functioning in terms of what they perceive to be normal under the circumstances. Their answers can be interpreted in terms of change in the appraisal process (Rapkin and Schwartz 2004; Health and Quality of Life Outcomes, 2, 14). More care should be taken in assessing the quality of a set of questions about physical and role functioning.

  13. Patient-reported outcome measures versus inertial performance-based outcome measures: A prospective study in patients undergoing primary total knee arthroplasty.

    PubMed

    Bolink, S A A N; Grimm, B; Heyligers, I C

    2015-12-01

    Outcome assessment of total knee arthroplasty (TKA) by subjective patient reported outcome measures (PROMs) may not fully capture the functional (dis-)abilities of relevance. Objective performance-based outcome measures could provide distinct information. An ambulant inertial measurement unit (IMU) allows kinematic assessment of physical performance and could potentially be used for routine follow-up. To investigate the responsiveness of IMU measures in patients following TKA and compare outcomes with conventional PROMs. Patients with end stage knee OA (n=20, m/f=7/13; age=67.4 standard deviation 7.7 years) were measured preoperatively and one year postoperatively. IMU measures were derived during gait, sit-stand transfers and block step-up transfers. PROMs were assessed by using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and Knee Society Score (KSS). Responsiveness was calculated by the effect size, correlations were calculated with Spearman's rho correlation coefficient. One year after TKA, patients performed significantly better at gait, sit-to-stand transfers and block step-up transfers. Measures of time and kinematic IMU measures demonstrated significant improvements postoperatively for each performance-based test. The largest improvement was found in block step-up transfers (effect size=0.56-1.20). WOMAC function score and KSS function score demonstrated moderate correlations (Spearman's rho=0.45-0.74) with some of the physical performance-based measures pre- and postoperatively. To characterize the changes in physical function after TKA, PROMs could be supplemented by performance-based measures, assessing function during different activities and allowing kinematic characterization with an ambulant IMU. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Response functions of Fuji imaging plates to monoenergetic protons in the energy range 0.6-3.2 MeV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bonnet, T.; Denis-Petit, D.; Gobet, F.

    2013-01-15

    We have measured the responses of Fuji MS, SR, and TR imaging plates (IPs) to protons with energies ranging from 0.6 to 3.2 MeV. Monoenergetic protons were produced with the 3.5 MV AIFIRA (Applications Interdisciplinaires de Faisceaux d'Ions en Region Aquitaine) accelerator at the Centre d'Etudes Nucleaires de Bordeaux Gradignan (CENBG). The IPs were irradiated with protons backscattered off a tantalum target. We present the photo-stimulated luminescence response of the IPs together with the fading measurements for these IPs. A method is applied to allow correction of fading effects for variable proton irradiation duration. Using the IP fading corrections, amore » model of the IP response function to protons was developed. The model enables extrapolation of the IP response to protons up to proton energies of 10 MeV. Our work is finally compared to previous works conducted on Fuji TR IP response to protons.« less

  15. Modification of response functions of cat visual cortical cells by spatially congruent perturbing stimuli.

    PubMed

    Kabara, J F; Bonds, A B

    2001-12-01

    Responses of cat striate cortical cells to a drifting sinusoidal grating were modified by the superimposition of a second, perturbing grating (PG) that did not excite the cell when presented alone. One consequence of the presence of a PG was a shift in the tuning curves. The orientation tuning of all 41 cells exposed to a PG and the spatial frequency tuning of 83% of the 23 cells exposed to a PG showed statistically significant dislocations of both the response function peak and center of mass from their single grating values. As found in earlier reports, the presence of PGs suppressed responsiveness. However, reductions measured at the single grating optimum orientation or spatial frequency were on average 1.3 times greater than the suppression found at the peak of the response function modified by the presence of the PG. Much of the loss in response seen at the single grating optimum is thus a result of a shift in the tuning function rather than outright suppression. On average orientation shifts were repulsive and proportional (approximately 0.10 deg/deg) to the angle between the perturbing stimulus and the optimum single grating orientation. Shifts in the spatial frequency response function were both attractive and repulsive, resulting in an overall average of zero. For both simple and complex cells, PGs generally broadened orientation response function bandwidths. Similarly, complex cell spatial frequency response function bandwidths broadened. Simple cell spatial frequency response functions usually did not change, and those that did broadened only 4% on average. These data support the hypothesis that additional sinusoidal components in compound stimuli retune cells' response functions for orientation and spatial frequency.

  16. B-cell activation with CD40L or CpG measures the function of B-cell subsets and identifies specific defects in immunodeficient patients.

    PubMed

    Marasco, Emiliano; Farroni, Chiara; Cascioli, Simona; Marcellini, Valentina; Scarsella, Marco; Giorda, Ezio; Piano Mortari, Eva; Leonardi, Lucia; Scarselli, Alessia; Valentini, Diletta; Cancrini, Caterina; Duse, Marzia; Grimsholm, Ola; Carsetti, Rita

    2017-01-01

    Around 65% of primary immunodeficiencies are antibody deficiencies. Functional tests are useful tools to study B-cell functions in vitro. However, no accepted guidelines for performing and evaluating functional tests have been issued yet. Here, we report our experience on the study of B-cell functions in infancy and throughout childhood. We show that T-independent stimulation with CpG measures proliferation and differentiation potential of memory B cells. Switched memory B cells respond better than IgM memory B cells. On the other hand, CD40L, a T-dependent stimulus, does not induce plasma cell differentiation, but causes proliferation of naïve and memory B cells. During childhood, the production of plasmablasts in response to CpG increases with age mirroring the development of memory B cells. The response to CD40L does not change with age. In patients with selective IgA deficiency (SIgAD), we observed that switched memory B cells are reduced due to the absence of IgA memory B cells. In agreement, IgA plasma cells are not generated in response to CpG. Unexpectedly, B cells from SIgAD patients show a reduced proliferative response to CD40L. Our results demonstrate that functional tests are an important tool to assess the functions of the humoral immune system. © 2016 The Authors. European Journal of Immunology published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Optimization of canopy conductance models from concurrent measurements of sap flow and stem water potential on Drooping Sheoak in South Australia

    NASA Astrophysics Data System (ADS)

    Wang, H.; Guan, H.; Deng, R.; Simmons, C. T.

    2013-12-01

    Canopy conductance response to environmental conditions is a critical component in land surface hydrological modeling. This response is often formulated as a combination of response functions of each influencing factor (solar radiation, air temperature, vapor pressure deficit, and soil water availability). These functions are climate and vegetation specific. Thus, it is important to determine the most appropriate combination of response functions and their parameter values for a specific environment. We will present a method for this purpose based on field measurements and an optimization scheme. The study was performed on Drooping Sheoak (Allocasuarina verticillata) in Adelaide South Australia. Sap flow and stem water potential were measured in a year together with microclimate variables. Canopy conductance was calculated from the inversed Penman-Monteith (PM) equation, which was then used to examine the performance of 36 combinations of various response functions. Parameters in the models were optimized using a DiffeRential Evolution Adaptive Metropolis (DREAM) model based on a training dataset. The testing results show that the best combination gave a correlation coefficient of 0.97, and root mean square error of 0.0006 m/s in comparison to the PM-calculated values. The maximum stomatal conductance given by this combination is 0.0075 m/s, equivalent to a minimum stomatal resistance of 133 s/m. This is close to the number (150 s/m) used in Noah land surface model for evergreen needle-leaf trees. It is surprising that for all combinations, the optimized parameter of the temperature response function is against its physical meaning. This is likely related to the inter-dependence between air temperature and vapor pressure deficit. Supported by the results, we suggest that the effects of vapor pressure deficit and air temperature should be represented together, so as to be consistent with the physics.

  18. Child pain catastrophizing mediates the relationship between parent responses to pain and disability in youth with functional abdominal pain

    PubMed Central

    Cunningham, Natoshia Raishevich; Lynch-Jordan, Anne; Barnett, Kimberly; Peugh, James; Sil, Soumitri; Goldschneider, Kenneth; Kashikar-Zuck, Susmita

    2014-01-01

    Objectives Functional abdominal pain (FAP) in youth is associated with substantial impairment in functioning and prior research has shown that overprotective parent responses can heighten impairment. Little is known about how a range of parental behaviors in response to their child’s pain (overprotection, minimizing and/or encouragement) interact with child coping characteristics (e.g., catastrophizing) to influence functioning in youth with FAP. In this study, it was hypothesized that the relationship between parenting factors and child disability would be mediated by children’s level of maladaptive coping (i.e., pain catastrophizing). Methods Seventy-five patients with FAP presenting to a pediatric pain clinic and their caregivers participated. Youth completed measures of pain intensity (Numeric Rating Scale), pain catastrophizing (Pain Catastrophizing Scale), and disability (Functional Disability Inventory). Caregivers completed measures of parent pain catastrophizing (Pain Catastrophizing Scale), and parent responses to child pain behaviors (Adult Responses to Child Symptoms: protection, minimizing, and encouragement/monitoring subscales). Results Increased functional disability was significantly related to higher child pain intensity, increased child and parent pain catastrophizing, and higher levels of encouragement/monitoring and protection. Parent minimization was not related to disability. Child pain catastrophizing fully mediated the relationship between parent encouragement/monitoring and disability and partially mediated the relationship between parent protectiveness and disability. Conclusions The impact of parenting behaviors in response to FAP on child disability is determined in part by the child’s coping style. Findings highlight a more nuanced understanding of the parent-child interaction in determining pain-related disability levels, which should be taken into consideration in assessing and treating youth with FAP. PMID:25121521

  19. The frequency response of dynamic friction: Enhanced rate-and-state models

    NASA Astrophysics Data System (ADS)

    Cabboi, A.; Putelat, T.; Woodhouse, J.

    2016-07-01

    The prediction and control of friction-induced vibration requires a sufficiently accurate constitutive law for dynamic friction at the sliding interface: for linearised stability analysis, this requirement takes the form of a frictional frequency response function. Systematic measurements of this frictional frequency response function are presented for small samples of nylon and polycarbonate sliding against a glass disc. Previous efforts to explain such measurements from a theoretical model have failed, but an enhanced rate-and-state model is presented which is shown to match the measurements remarkably well. The tested parameter space covers a range of normal forces (10-50 N), of sliding speeds (1-10 mm/s) and frequencies (100-2000 Hz). The key new ingredient in the model is the inclusion of contact stiffness to take into account elastic deformations near the interface. A systematic methodology is presented to discriminate among possible variants of the model, and then to identify the model parameter values.

  20. Visual Cortical Function in Very Low Birth Weight Infants without Retinal or Cerebral Pathology

    PubMed Central

    Hou, Chuan; Norcia, Anthony M.; Madan, Ashima; Tith, Solina; Agarwal, Rashi

    2011-01-01

    Purpose. Preterm infants are at high risk of visual and neural developmental deficits. However, the development of visual cortical function in preterm infants with no retinal or neurologic morbidity has not been well defined. To determine whether premature birth itself alters visual cortical function, swept parameter visual evoked potential (sVEP) responses of healthy preterm infants were compared with those of term infants. Methods. Fifty-two term infants and 58 very low birth weight (VLBW) infants without significant retinopathy of prematurity or neurologic morbidities were enrolled. Recruited VLBW infants were between 26 and 33 weeks of gestational age, with birth weights of less than 1500 g. Spatial frequency, contrast, and vernier offset sweep VEP tuning functions were measured at 5 to 7 months' corrected age. Acuity and contrast thresholds were derived by extrapolating the tuning functions to 0 amplitude. These thresholds and suprathreshold response amplitudes were compared between groups. Results. Preterm infants showed increased thresholds (indicating decreased sensitivity to visual stimuli) and reductions in amplitudes for all three measures. These changes in cortical responsiveness were larger in the <30 weeks ' gestational age subgroup than in the ≥30 weeks' gestational age subgroup. Conclusions. Preterm infants with VLBW had measurable and significant changes in cortical responsiveness that were correlated with gestational age. These results suggest that premature birth in the absence of identifiable retinal or neurologic abnormalities has a significant effect on visual cortical sensitivity at 5 to 7 months' of corrected age and that gestational age is an important factor in visual development. PMID:22025567

  1. Sustained and transient attention in the continuous performance task.

    PubMed

    Smid, H G O M; de Witte, M R; Homminga, I; van den Bosch, R J

    2006-08-01

    One of the most frequently applied methods to study abnormal cognition is the Continuous Performance Task (CPT). It is unclear, however, which cognitive functions are engaged in normal CPT performance. The aims of the present study were to identify the neurocognitive functions engaged in the main variants of the CPT and to determine to what extent these variants differentially engage these functions. We hypothesized that the main CPT versions (CPT-X, CPT-AX, CPT-Identical Pairs) can be distinguished by whether they demand sustained or transient attention and sustained or transient response preparation. Transient attention to objects like letters or digits, that is, the need to switch attention to different objects from trial to trial, impairs target detection accuracy relative to sustained attention to a single object. Transient response preparation, that is, the possibility to switch response preparation on and off from trial to trial, improves response speed relative to having to sustain response preparation across all trials. Comparison of task performance and Event-Related brain Potentials (ERPs) of healthy participants obtained in the main CPT variants confirmed these hypotheses. Behavioral and ERP measures indicated worse target detection in the CPT-AX than in the CPT-X, consistent with a higher demand on transient attention in that task. In contrast, behavioral and ERP measures indicated higher response speed in the CPT-AX than in the CPT-X, associated with more response preparation in advance of the targets. This supports the idea of increased transient response preparation in the CPT-AX. We conclude that CPTs differ along at least two task variables that each influences a different cognitive function.

  2. Determining Concentration of Nanoparticles from Ellipsometry

    NASA Technical Reports Server (NTRS)

    Venkatasubbarao, Srivatsa; Kempen, Lothar U.; Chipman, Russell

    2008-01-01

    A method of using ellipsometry or polarization analysis of light in total internal reflection of a surface to determine the number density of gold nanoparticles on a smooth substrate has been developed. The method can be modified to enable determination of densities of sparse distributions of nanoparticles in general, and is expected to be especially useful for measuring gold-nanoparticle-labeled biomolecules on microarrays. The method is based on theoretical calculations of the ellipsometric responses of gold nanoparticles. Elements of the calculations include the following: For simplicity, the gold nanoparticles are assumed to be spherical and to have the same radius. The distribution of gold nanoparticles is assumed to be a sub-monolayer (that is, sparser than a monolayer). The optical response of the sub-monolayer is modeled by use of a thin-island-film theory, according to which the polarizabilities parallel and perpendicular to the substrate are functions of the wavelength of light, the dielectric functions (permittivities expressed as complex functions of frequency or wavelength) of the gold and the suspending medium (in this case, the suspending medium is air), the fraction of the substrate area covered by the nanoparticles, and the radius of the nanoparticles. For the purpose of the thin-island-film theory, the dielectric function of the gold nanoparticles is modeled as the known dielectric function of bulk gold plus a correction term that is necessitated by the fact that the mean free path length for electrons in gold decreases with decreasing radius, in such a manner as to cause the imaginary part of the dielectric function to increase with decreasing radius (see figure). The correction term is a function of the nanoparticle radius, the wavelength of light, the mean free path and the Fermi speed of electrons in bulk gold, the plasma frequency of gold, and the speed of light in a vacuum. These models are used to calculate ellipsometric responses for various concentrations of gold nanoparticles having an assumed radius. The modeled data indicates distinct spectral features for both the real and the imaginary part of the dielectric function. An ellipsometric measurement would determine this distinct feature and thus can be used to measure nanoparticle concentration. By "ellipsometric responses" is meant the intensities of light measured in various polarization states as functions of the angle of incidence and the polarization states of the incident light. These calculated ellipsometric responses are used as calibration curves: Data from subsequent ellipsometric measurements on real specimens are compared with the calibration curves. The concentration of the nanoparticles on a specimen is assumed to be that of the calibration curve that most closely matches the data pertaining to that specimen.

  3. Testing for Neuropsychological Endophenotypes in Siblings Discordant for ADHD

    PubMed Central

    Bidwell, L. Cinnamon; Willcutt, Erik G.; DeFries, John C.; Pennington, Bruce F.

    2007-01-01

    Objective Neurocognitive deficits associated with attention deficit-hyperactivity disorder (ADHD) may be useful intermediate endophenotypes for determining specific genetic pathways that contribute to ADHD. Methods This study administered 17 measures from prominent neuropsychological theories of ADHD (executive function, processing speed, arousal regulation and motivation/delay aversion) in dizygotic (DZ) twin pairs discordant for ADHD and control twin pairs (ages 8–18) in order to compare performance between twins affected with ADHD (n = 266), their unaffected co-twins (n = 228), and control children from twin pairs without ADHD or learning difficulties (n = 332). Results ADHD subjects show significant impairment on executive function, processing speed, and response variability measures compared to control subjects. Unaffected cotwins of ADHD subjects are significantly impaired on nearly all the same measures as their ADHD siblings, even when subclinical symptoms of ADHD are controlled. Conclusion Executive function, processing speed, and response variability deficits may be useful endophenotypes for genetic studies of ADHD. PMID:17585884

  4. Daily Spouse Responsiveness Predicts Longer-Term Trajectories of Physical Function

    PubMed Central

    Wilson, Stephanie J.; Martire, Lynn M.; Sliwinski, Martin J.

    2017-01-01

    Everyday interpersonal experiences may underlie the well-established link between close relationships and physical health, but multitemporal designs necessary for strong conclusions about temporal sequence are rare. The current study of 145 knee osteoarthritis patients and their spouses focused on a novel pattern in everyday interactions, daily spouse responsiveness—the degree to which spouse responses are calibrated to changes in patients’ everyday verbal pain expression. Using couple-level slopes, multilevel latent-variable growth models tested associations between three types of daily spouse responsiveness (empathic, solicitous, and punishing), as measured during a 3-week experience-sampling study, and change in patient physical function across 18 months. As predicted, patients whose spouses were more empathically responsive to their pain expression showed better physical function over time compared to those whose spouses were less empathically responsive. This study points to daily responsiveness, a theoretically rooted operationalization of spouse sensitivity, as important for long-term changes in objective physical function. PMID:28459650

  5. Contributions of Modern Measurement Theory to Measuring Executive Function in Early Childhood: An Empirical Demonstration

    ERIC Educational Resources Information Center

    Willoughby, Michael T.; Wirth, R. J.; Blair, Clancy B.

    2011-01-01

    This study demonstrates the merits of evaluating a newly developed battery of executive function tasks, designed for use in early childhood, from the perspective of item response theory (IRT). The battery was included in the 48-month assessment of the Family Life Project, a prospective longitudinal study of 1292 children oversampled from…

  6. Reproducibility of the retinal vascular response to flicker light in Asians.

    PubMed

    Nguyen, Thanh T; Kreis, Andreas J; Kawasaki, Ryo; Wang, Jie Jin; Seifert, Bernd-U; Vilser, Walthard; Nagel, Edgar; Wong, Tien Y

    2009-12-01

    Dilation of retinal vessels in response to diffuse luminance flicker may reflect endothelial function. Although this has previously been shown to be reproducible in whites, there have been no similar data in Asians. We assess the reproducibility of repeated measurements of this response in Asians. Healthy Asians (n = 33) with normal vision and no history of glaucoma, age-related macular degeneration, cataract, or retinal arterial/venous occlusion participated in this study. Repeated measures from the same subjects were taken 30-60 min apart using the Dynamic Vessel Analyser (DVA, IMEDOS, Jena, Germany). Modification was made to the shape of the light source for Asian participants. Correlations of the first and second measures were assessed using Pearson correlation (R(2)), and agreement between the two measures was shown using Bland-Altman plots. After modification to the shape of the light source, almost perfect correlation was found between the 1st and 2nd measurements of baseline arteriolar (R(2) = 0.95) and venular diameters (R(2) = 0.98) of arteriolar maximum dilation (R(2) = 0.85). Substantially high correlation between the 1st and 2nd measurements of venular maximum dilation was found (R(2) = 0.80). Measurements of the dilation response of retinal vessels to diffuse luminance flicker an Asian sample using the DVA show high reproducibility for repeated measures over a short period of time. Such measurements may allow non-invasive quantification of endothelial function to study its association with systemic and ocular diseases.

  7. Novel assessment tools to evaluate clinical and laboratory responses in a subset of patients enrolled in the Rituximab in Myositis trial.

    PubMed

    Rider, Lisa G; Yip, Adrienne L; Horkayne-Szakaly, Iren; Volochayev, Rita; Shrader, Joseph A; Turner, Maria L; Kong, Heidi H; Jain, Minal S; Jansen, Anna V; Oddis, Chester V; Fleisher, Thomas A; Miller, Frederick W

    2014-01-01

    We aimed to assess changes in myositis core set measures and ancillary clinical and laboratory data from the National Institutes of Health's subset of patients enrolled in the Rituximab in Myositis trial. Eighteen patients (5 dermatomyositis, 8 polymyositis, 5 juvenile dermatomyositis) completed more in-depth testing of muscle strength and cutaneous assessments, patient-reported outcomes, and laboratory tests before and after administration of rituximab. Percentage change in individual measures and in the definitions of improvement (DOIs) and standardized response means were examined over 44 weeks. Core set activity measures improved by 18-70% from weeks 0-44 and were sensitive to change. Fifteen patients met the DOI at week 44, 9 patients met a DOI 50% response, and 4 met a DOI 70% response. Muscle strength and function measures were more sensitive to change than cutaneous assessments. Constitutional, gastrointestinal, and pulmonary systems improved 44-70%. Patient-reported outcomes improved up to 28%. CD20+ B cells were depleted in the periphery, but B cell depletion was not associated with clinical improvement at week 16. This subset of patients had high rates of clinical response to rituximab, similar to patients in the overall trial. Most measures were responsive, and muscle strength had a greater degree of change than cutaneous assessments. Several novel assessment tools, including measures of strength and function, extra-muscular organ activity, fatigue, and health-related quality of life, are promising for use in future myositis trials. Further study of B cell-depleting therapies in myositis, particularly in treatment-naïve patients, is warranted.

  8. Predicting Treatment Response in Social Anxiety Disorder From Functional Magnetic Resonance Imaging

    PubMed Central

    Doehrmann, Oliver; Ghosh, Satrajit S.; Polli, Frida E.; Reynolds, Gretchen O.; Horn, Franziska; Keshavan, Anisha; Triantafyllou, Christina; Saygin, Zeynep M.; Whitfield-Gabrieli, Susan; Hofmann, Stefan G.; Pollack, Mark; Gabrieli, John D.

    2013-01-01

    Context Current behavioral measures poorly predict treatment outcome in social anxiety disorder (SAD). To our knowledge, this is the first study to examine neuroimaging-based treatment prediction in SAD. Objective To measure brain activation in patients with SAD as a biomarker to predict subsequent response to cognitive behavioral therapy (CBT). Design Functional magnetic resonance imaging (fMRI) data were collected prior to CBT intervention. Changes in clinical status were regressed on brain responses and tested for selectivity for social stimuli. Setting Patients were treated with protocol-based CBT at anxiety disorder programs at Boston University or Massachusetts General Hospital and underwent neuroimaging data collection at Massachusetts Institute of Technology. Patients Thirty-nine medication-free patients meeting DSM-IV criteria for the generalized subtype of SAD. Interventions Brain responses to angry vs neutral faces or emotional vs neutral scenes were examined with fMRI prior to initiation of CBT. Main Outcome Measures Whole-brain regression analyses with differential fMRI responses for angry vs neutral faces and changes in Liebowitz Social Anxiety Scale score as the treatment outcome measure. Results Pretreatment responses significantly predicted subsequent treatment outcome of patients selectively for social stimuli and particularly in regions of higher-order visual cortex. Combining the brain measures with information on clinical severity accounted for more than 40% of the variance in treatment response and substantially exceeded predictions based on clinical measures at baseline. Prediction success was unaffected by testing for potential confounding factors such as depression severity at baseline. Conclusions The results suggest that brain imaging can provide biomarkers that substantially improve predictions for the success of cognitive behavioral interventions and more generally suggest that such biomarkers may offer evidence-based, personalized medicine approaches for optimally selecting among treatment options for a patient. PMID:22945462

  9. Comparing capacity coefficient and dual task assessment of visual multitasking workload

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blaha, Leslie M.

    Capacity coefficient analysis could offer a theoretically grounded alternative approach to subjective measures and dual task assessment of cognitive workload. Workload capacity or workload efficiency is a human information processing modeling construct defined as the amount of information that can be processed by the visual cognitive system given a specified of amount of time. In this paper, I explore the relationship between capacity coefficient analysis of workload efficiency and dual task response time measures. To capture multitasking performance, I examine how the relatively simple assumptions underlying the capacity construct generalize beyond the single visual decision making tasks. The fundamental toolsmore » for measuring workload efficiency are the integrated hazard and reverse hazard functions of response times, which are defined by log transforms of the response time distribution. These functions are used in the capacity coefficient analysis to provide a functional assessment of the amount of work completed by the cognitive system over the entire range of response times. For the study of visual multitasking, capacity coefficient analysis enables a comparison of visual information throughput as the number of tasks increases from one to two to any number of simultaneous tasks. I illustrate the use of capacity coefficients for visual multitasking on sample data from dynamic multitasking in the modified Multi-attribute Task Battery.« less

  10. SU-E-P-29: Testing Display Monitors for GSDF Compliance - a Practical Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gauntt, D

    2015-06-15

    Purpose: To develop a simple technique for testing display monitors for compliance with the DICOM Grayscale Standard Display Function (GSDF), in accordance with the recommendations of AAPM Task Group 18. Methods: We have developed a spreadsheet that can be used to compare both the luminance response and contrast response of a display to the GSDF, using luminance measurements of the SMPTE test pattern. The contrast response compares the slope of the GSDF j-index as a function of pixel value to that of the GSDF function, and should lie within the range 0.85 to 1.15. Results: We present the results ofmore » measurements both of primary diagnostic displays and of ultrasound and acquisition workstations, all at a tertiary care hospital. The Barco displays in the radiographic reading rooms are GSDF compliant or nearly so, while those in the ultrasound reading rooms and at the acquisition workstations generally show significantly higher contrast at low luminance levels than they would if GSDF compliant, and lower contrast at high luminance levels. Conclusion: The spreadsheet that we developed allows a simple comparison of measured display contrast response to the GSDF. Although we used the SMPTE pattern, the same technique could be used with other grayscale patterns, such as TG18-QC and TG18-PQC.« less

  11. GADRAS-DRF 18.6 User's Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Horne, Steve M.; Thoreson, Greg G.; Theisen, Lisa A.

    2016-05-01

    The Gamma Detector Response and Analysis Software–Detector Response Function (GADRAS-DRF) application computes the response of gamma-ray and neutron detectors to incoming radiation. This manual provides step-by-step procedures to acquaint new users with the use of the application. The capabilities include characterization of detector response parameters, plotting and viewing measured and computed spectra, analyzing spectra to identify isotopes, and estimating source energy distributions from measured spectra. GADRAS-DRF can compute and provide detector responses quickly and accurately, giving users the ability to obtain usable results in a timely manner (a matter of seconds or minutes).

  12. Neural Responses to Heartbeats in the Default Network Encode the Self in Spontaneous Thoughts.

    PubMed

    Babo-Rebelo, Mariana; Richter, Craig G; Tallon-Baudry, Catherine

    2016-07-27

    The default network (DN) has been consistently associated with self-related cognition, but also to bodily state monitoring and autonomic regulation. We hypothesized that these two seemingly disparate functional roles of the DN are functionally coupled, in line with theories proposing that selfhood is grounded in the neural monitoring of internal organs, such as the heart. We measured with magnetoencephalograhy neural responses evoked by heartbeats while human participants freely mind-wandered. When interrupted by a visual stimulus at random intervals, participants scored the self-relatedness of the interrupted thought. They evaluated their involvement as the first-person perspective subject or agent in the thought ("I"), and on another scale to what degree they were thinking about themselves ("Me"). During the interrupted thought, neural responses to heartbeats in two regions of the DN, the ventral precuneus and the ventromedial prefrontal cortex, covaried, respectively, with the "I" and the "Me" dimensions of the self, even at the single-trial level. No covariation between self-relatedness and peripheral autonomic measures (heart rate, heart rate variability, pupil diameter, electrodermal activity, respiration rate, and phase) or alpha power was observed. Our results reveal a direct link between selfhood and neural responses to heartbeats in the DN and thus directly support theories grounding selfhood in the neural monitoring of visceral inputs. More generally, the tight functional coupling between self-related processing and cardiac monitoring observed here implies that, even in the absence of measured changes in peripheral bodily measures, physiological and cognitive functions have to be considered jointly in the DN. The default network (DN) has been consistently associated with self-processing but also with autonomic regulation. We hypothesized that these two functions could be functionally coupled in the DN, inspired by theories according to which selfhood is grounded in the neural monitoring of internal organs. Using magnetoencephalography, we show that heartbeat-evoked responses (HERs) in the DN covary with the self-relatedness of ongoing spontaneous thoughts. HER amplitude in the ventral precuneus covaried with the "I" self-dimension, whereas HER amplitude in the ventromedial prefrontal cortex encoded the "Me" self-dimension. Our experimental results directly support theories rooting selfhood in the neural monitoring of internal organs. We propose a novel functional framework for the DN, where self-processing is coupled with physiological monitoring. Copyright © 2016 Babo-Rebelo et al.

  13. Neural Responses to Heartbeats in the Default Network Encode the Self in Spontaneous Thoughts

    PubMed Central

    Babo-Rebelo, Mariana; Richter, Craig G.

    2016-01-01

    The default network (DN) has been consistently associated with self-related cognition, but also to bodily state monitoring and autonomic regulation. We hypothesized that these two seemingly disparate functional roles of the DN are functionally coupled, in line with theories proposing that selfhood is grounded in the neural monitoring of internal organs, such as the heart. We measured with magnetoencephalograhy neural responses evoked by heartbeats while human participants freely mind-wandered. When interrupted by a visual stimulus at random intervals, participants scored the self-relatedness of the interrupted thought. They evaluated their involvement as the first-person perspective subject or agent in the thought (“I”), and on another scale to what degree they were thinking about themselves (“Me”). During the interrupted thought, neural responses to heartbeats in two regions of the DN, the ventral precuneus and the ventromedial prefrontal cortex, covaried, respectively, with the “I” and the “Me” dimensions of the self, even at the single-trial level. No covariation between self-relatedness and peripheral autonomic measures (heart rate, heart rate variability, pupil diameter, electrodermal activity, respiration rate, and phase) or alpha power was observed. Our results reveal a direct link between selfhood and neural responses to heartbeats in the DN and thus directly support theories grounding selfhood in the neural monitoring of visceral inputs. More generally, the tight functional coupling between self-related processing and cardiac monitoring observed here implies that, even in the absence of measured changes in peripheral bodily measures, physiological and cognitive functions have to be considered jointly in the DN. SIGNIFICANCE STATEMENT The default network (DN) has been consistently associated with self-processing but also with autonomic regulation. We hypothesized that these two functions could be functionally coupled in the DN, inspired by theories according to which selfhood is grounded in the neural monitoring of internal organs. Using magnetoencephalography, we show that heartbeat-evoked responses (HERs) in the DN covary with the self-relatedness of ongoing spontaneous thoughts. HER amplitude in the ventral precuneus covaried with the “I” self-dimension, whereas HER amplitude in the ventromedial prefrontal cortex encoded the “Me” self-dimension. Our experimental results directly support theories rooting selfhood in the neural monitoring of internal organs. We propose a novel functional framework for the DN, where self-processing is coupled with physiological monitoring. PMID:27466329

  14. Scale Refinement and Initial Evaluation of a Behavioral Health Function Measurement Tool for Work Disability Evaluation

    PubMed Central

    Marfeo, Elizabeth E.; Ni, Pengsheng; Bogusz, Kara; Meterko, Mark; McDonough, Christine M.; Chan, Leighton; Rasch, Elizabeth K.; Brandt, Diane E.; Jette, Alan M.

    2014-01-01

    Objectives To use item response theory (IRT) data simulations to construct and perform initial psychometric testing of a newly developed instrument, the Social Security Administration Behavioral Health Function (SSA-BH) instrument, that aims to assess behavioral health functioning relevant to the context of work. Design Cross-sectional survey followed by item response theory (IRT) calibration data simulations Setting Community Participants A sample of individuals applying for SSA disability benefits, claimants (N=1015), and a normative comparative sample of US adults (N=1000) Interventions None. Main Outcome Measure Social Security Administration Behavioral Health Function (SSA-BH) measurement instrument Results Item response theory analyses supported the unidimensionality of four SSA-BH scales: Mood and Emotions (35 items), Self-Efficacy (23 items), Social Interactions (6 items), and Behavioral Control (15 items). All SSA-BH scales demonstrated strong psychometric properties including reliability, accuracy, and breadth of coverage. High correlations of the simulated 5- or 10- item CATs with the full item bank indicated robust ability of the CAT approach to comprehensively characterize behavioral health function along four distinct dimensions. Conclusions Initial testing and evaluation of the SSA-BH instrument demonstrated good accuracy, reliability, and content coverage along all four scales. Behavioral function profiles of SSA claimants were generated and compared to age and sex matched norms along four scales: Mood and Emotions, Behavioral Control, Social Interactions, and Self-Efficacy. Utilizing the CAT based approach offers the ability to collect standardized, comprehensive functional information about claimants in an efficient way, which may prove useful in the context of the SSA’s work disability programs. PMID:23542404

  15. Analysis And Validation of the Field Coupled Through an Aperture in an Avionics Enclosure

    NASA Astrophysics Data System (ADS)

    Bakore, Rahul

    This work focused on accurately predicting the current response of an equipment under test (EUT) to a random electromagnetic field representing a threat source to model radio frequency directed energy weapons (RFDEWs). The modeled EUT consists of a single wire attached to the interior wall of a shielding enclosure that includes an aperture on one face. An in-house computational electromagnetic (CEM) code based on method of moments (MOM) and accelerated by the multi-level fast multipole algorithm (MLFMA), was enhanced through the implementation of first order vector basis functions that approximates the EUT surface current. The electric field integral equation (EFIE) is solved using MOM/MLFMA. Use of first-order basis functions gives a large savings in computational time over the previous implementation with zero-order Rao-Wilton-Glisson basis functions. A sample EUT was fabricated and tested within an anechoic chamber and a reverberation chamber over a wide frequency band. In the anechoic chamber measurements, the current response on the wire within the EUT due to a single uniform plane wave was found and compared with the numerical simulations. In the reverberation chamber measurements, the mean current magnitude excited on the wire within the EUT by a mechanically stirred random field was measured and compared with the numerical simulations. The measured scattering parameter between the source antenna and the EUT measurement port was used to derive the current response on the wire in both chambers. The numerically simulated currents agree very well with the measurements in both the anechoic and reverberation chambers over the measured frequency band, confirming the validity of the numerical approach for calculating EUT response due to a random field. An artificial neural network (ANN) was trained that can rapidly provide the mean induced current response of an EUT due to a random field under different aperture configurations arbitrarily placed on one face of an EUT. However, ANN proved no better than simple linear interpolation in approximating the induced currents on EUTs that give strong resonances and nulls in the response.

  16. Autonomic Function in Infancy.

    ERIC Educational Resources Information Center

    Fox, Nathan A.; Fitzgerald, Hiram E.

    1990-01-01

    Reviews research that uses autonomic responses of human infants as dependent measures. Focuses on the history of research on the autonomic nervous system, measurement issues, and autonomic correlates of infant behavior and systems. (RJC)

  17. Why is impaired sexual function distressing to women? The primacy of pleasure in female sexual dysfunction.

    PubMed

    Stephenson, Kyle R; Meston, Cindy M

    2015-03-01

    Recent research has highlighted a complex association between female sexual function and subjective distress regarding sexual activity. These findings are difficult to explain given limited knowledge as to the mechanisms through which impaired sexual function causes distress. The current study assessed whether a number of specific consequences of impaired sexual function, including decreased physical pleasure, disruption of sexual activity, and negative partner responses, mediated the association between sexual function and distress. Eighty-seven women in sexually active relationships reporting impairments in sexual function completed validated self-report measures and daily online assessments of sexual experiences. Participants completed the Sexual Satisfaction Scale for Women, the Female Sexual Function Index, and the Measure of Sexual Consequences. Results suggested that decreased physical pleasure and disruption of sexual activity, but not partner responses, statistically mediated the association between sexual function and distress. Sexual consequences represent potential maintaining factors of sexual dysfunction that are highly distressing to women. Results are discussed in the context of theoretical models of sexual dysfunction and related treatments. © 2014 International Society for Sexual Medicine.

  18. Exploratory studies of physiological components of motion sickness: Cardiopulmonary differences between high and low susceptibles

    NASA Technical Reports Server (NTRS)

    Naifeh, K.

    1985-01-01

    A comprehensive examination of cardiovascular autonomic response to motion sickness was studied and whether differences in cardiopulmonary function exist in high and low susceptibility groups were determined. Measurement techniques were developed as was test equipment for its ability to provide accurately new measures of interest and to test the adequately of these new measures in differentiating between susceptibility groups. It was concluded that these groups can be differentiated using simple, brief stressors and measurements of cardiodynamic function.

  19. Measurement of the Spatial Distribution of the Spectral Response Variation in the Field of View of the ASD Spectrometer Input Optics

    DTIC Science & Technology

    2014-12-01

    development. It will be used for the measurement of the spectro-polarimetric BRDF (Bidirectional Reflectance Distribution function). For practical reasons...goniomètre est en développement. Il sera utilisé pour les mesures de BRDF (fonction de distribution de réflectance bidirectionnelle) spectrales et...by the independent measurements of the spectral and Bidirectional Reflectance Distribution Function ( BRDF ). The BRDF is the measurement of the

  20. Sleep and Cognitive Function in Multiple Sclerosis.

    PubMed

    Braley, Tiffany J; Kratz, Anna L; Kaplish, Neeraj; Chervin, Ronald D

    2016-08-01

    To examine associations between cognitive performance and polysomnographic measures of obstructive sleep apnea in patients with multiple sclerosis (MS). Participants underwent a comprehensive MS-specific cognitive testing battery (the Minimal Assessment of Cognitive Function in MS, or MACFIMS) and in-laboratory overnight PSG. In adjusted linear regression models, the oxygen desaturation index (ODI) and minimum oxygen saturation (MinO2) were significantly associated with performance on multiple MACFIMS measures, including the Paced Auditory Serial Addition Test (PASAT; 2-sec and 3-sec versions), which assesses working memory, processing speed, and attention, and on the Brief Visuospatial Memory Test-Revised, a test of delayed visual memory. The respiratory disturbance index (RDI) was also significantly associated with PASAT-3 scores as well as the California Verbal Learning Test-II (CVLT-II) Discriminability Index, a test of verbal memory and response inhibition. Among these associations, apnea severity measures accounted for between 12% and 23% of the variance in cognitive test performance. Polysomnographic measures of sleep fragmentation (as reflected by the total arousal index) and total sleep time also showed significant associations with a component of the CVLT-II that assesses response inhibition, explaining 18% and 27% of the variance in performance. Among patients with MS, obstructive sleep apnea and sleep disturbance are significantly associated with diminished visual memory, verbal memory, executive function (as reflected by response inhibition), attention, processing speed, and working memory. If sleep disorders degrade these cognitive functions, effective treatment could offer new opportunities to improve cognitive functioning in patients with MS. A commentary on this article appears in this issue on page 1489. © 2016 Associated Professional Sleep Societies, LLC.

  1. Poor Response Inhibition as a Predictor of Problem Drinking and Illicit Drug Use in Adolescents at Risk for Alcoholism and Other Substance Use Disorders

    ERIC Educational Resources Information Center

    Nigg, Joel T.; Wong, Maria M.; Martel, Michelle M.; Jester, Jennifer M.; Puttler, Leon I.; Glass, Jennifer M.; Adams, Kenneth M.; Fitzgerald, Hiram E.; Zucker, Robert A.

    2006-01-01

    Objective: To evaluate the predictive power of executive functions, in particular, response inhibition, in relation to alcohol-related problems and illicit drug use in adolescence. Method: A total of 498 children from 275 families from a longitudinal high-risk study completed executive function measures in early and late adolescence and lifetime…

  2. Standardizing patient-reported outcomes assessment in cancer clinical trials: a patient-reported outcomes measurement information system initiative.

    PubMed

    Garcia, Sofia F; Cella, David; Clauser, Steven B; Flynn, Kathryn E; Lad, Thomas; Lai, Jin-Shei; Reeve, Bryce B; Smith, Ashley Wilder; Stone, Arthur A; Weinfurt, Kevin

    2007-11-10

    Patient-reported outcomes (PROs), such as symptom scales or more broad-based health-related quality-of-life measures, play an important role in oncology clinical trials. They frequently are used to help evaluate cancer treatments, as well as for supportive and palliative oncology care. To be most beneficial, these PROs must be relevant to patients and clinicians, valid, and easily understood and interpreted. The Patient-Reported Outcomes Measurement Information System (PROMIS) Network, part of the National Institutes of Health Roadmap Initiative, aims to improve appreciably how PROs are selected and assessed in clinical research, including clinical trials. PROMIS is establishing a publicly available resource of standardized, accurate, and efficient PRO measures of major self-reported health domains (eg, pain, fatigue, emotional distress, physical function, social function) that are relevant across chronic illnesses including cancer. PROMIS is also developing measures of self-reported health domains specifically targeted to cancer, such as sleep/wake function, sexual function, cognitive function, and the psychosocial impacts of the illness experience (ie, stress response and coping; shifts in self-concept, social interactions, and spirituality). We outline the qualitative and quantitative methods by which PROMIS measures are being developed and adapted for use in clinical oncology research. At the core of this activity is the formation and application of item banks using item response theory modeling. We also present our work in the fatigue domain, including a short-form measure, as a sample of PROMIS methodology and work to date. Plans for future validation and application of PROMIS measures are discussed.

  3. Characterization of the LANDSAT sensors' spatial responses

    NASA Technical Reports Server (NTRS)

    Markham, B. L.

    1984-01-01

    The characteristics of the thematic mapper (TM) and multispectral scanner (MSS) sensors on LANDSATs 4 and 5 affecting their spatial responses are described, and functions defining the response of the system to an arbitrary input spatial pattern are derived, i.e., transfer functions (TF) and line spread functions (LSF). These design LSF's and TF's were modified based on prelaunch component and system measurements to provide improved estimates. Prelaunch estimates of LSF/FT's are compared to in-orbit estimates. For the MSS instruments, only limited prelaunch scan direction square-wave response (SWR) data were available. Design estimates were modified by convolving in Gaussian blur till the derived LSF/TF's produced SWR's comparable to the measurements. The two MSS instruments were comparable at their temperatures of best focus; separate calculations were performed for bands 1 and 3, band 2 and band 4. The pre-sample nadir effective instantaneous field's of view (EIFOV's) based on the .5 modulation transfer function (MTF) criteria vary from 70 to 75 meters in the track direction and 79 to 82 meters in the scan direction. For the TM instruments more extensive prelaunch measurements were available. Bands 1 to 4, 5 and 7, and 6 were handled separately as were the two instruments. Derived MTF's indicate nadir pre-sample EIFOV's of 32 to 33 meter track (bands 1 to 5, 7) and 36 meter scan (bands 1 to 5, 7) and 1245 meter track (band 6) and 141 meter scan (band 6) for both TM's.

  4. Detecting effects of donepezil on visual selective attention using signal detection parameters in Alzheimer's disease.

    PubMed

    Foldi, Nancy S; White, Richard E C; Schaefer, Lynn A

    2005-05-01

    Attentional function is impaired in Alzheimer's disease (AD). Moreover, attention is mediated by acetylcholine. But, despite the widespread use of acetylcholinesterase inhibitors (AChE-I) to augment available acetylcholine in AD, measures of attentional function have not been used to assess the drug response. We hypothesized that as cholinergic augmentation impacts directly on the attentional system, higher-order measures of visual selective attention would be sensitive to effects of treatment using an AChE-I (donepezil hydrochloride). We also sought to determine whether these attentional measures were more sensitive to treatment than other measures of cognitive function. Seventeen patients with AD (8 untreated, 9 treated with donepezil) were contrasted on performance of a selective cancellation task. Two signal detection parameters were used as outcome measures: decision strategy (beta, beta) and discriminability (d-prime, d'). Standard screening and cognitive domain measures of vigilance, language, memory, and executive function were also contrasted. Treated patients judged stimuli more conservatively (p = 0.29) by correctly endorsing targets and rejecting false alarms. They also discriminated targets from distractors more easily (p = 0.58). The screening and neuropsychological measures failed to differentiate the groups. Higher-order attentional measures captured the effects of donepezil treatment in small groups of patients with AD. The results suggest that cholinergic availability may directly affect the attentional system, and that these selective attention measures are sensitive markers to detect treatment response. Copyright 2005 John Wiley & Sons, Ltd.

  5. Quantitative myocardial perfusion from static cardiac and dynamic arterial CT

    NASA Astrophysics Data System (ADS)

    Bindschadler, Michael; Branch, Kelley R.; Alessio, Adam M.

    2018-05-01

    Quantitative myocardial blood flow (MBF) estimation by dynamic contrast enhanced cardiac computed tomography (CT) requires multi-frame acquisition of contrast transit through the blood pool and myocardium to inform the arterial input and tissue response functions. Both the input and the tissue response functions for the entire myocardium are sampled with each acquisition. However, the long breath holds and frequent sampling can result in significant motion artifacts and relatively high radiation dose. To address these limitations, we propose and evaluate a new static cardiac and dynamic arterial (SCDA) quantitative MBF approach where (1) the input function is well sampled using either prediction from pre-scan timing bolus data or measured from dynamic thin slice ‘bolus tracking’ acquisitions, and (2) the whole-heart tissue response data is limited to one contrast enhanced CT acquisition. A perfusion model uses the dynamic arterial input function to generate a family of possible myocardial contrast enhancement curves corresponding to a range of MBF values. Combined with the timing of the single whole-heart acquisition, these curves generate a lookup table relating myocardial contrast enhancement to quantitative MBF. We tested the SCDA approach in 28 patients that underwent a full dynamic CT protocol both at rest and vasodilator stress conditions. Using measured input function plus single (enhanced CT only) or plus double (enhanced and contrast free baseline CT’s) myocardial acquisitions yielded MBF estimates with root mean square (RMS) error of 1.2 ml/min/g and 0.35 ml/min/g, and radiation dose reductions of 90% and 83%, respectively. The prediction of the input function based on timing bolus data and the static acquisition had an RMS error compared to the measured input function of 26.0% which led to MBF estimation errors greater than threefold higher than using the measured input function. SCDA presents a new, simplified approach for quantitative perfusion imaging with an acquisition strategy offering substantial radiation dose and computational complexity savings over dynamic CT.

  6. Plant ecophysiology and forest response to global change.

    PubMed

    Buchmann, N

    2002-11-01

    There are many ways of studying forest responses to global change. Most current national and international programs focus on net gas exchange of the terrestrial biosphere and are typically interdisciplinary, multi-scale projects. Key objectives of these programs are surprisingly similar to those of classical plant ecophysiology studies, i.e., to explore functional relationships of plant or plant community responses to environmental change. Thus, common research questions that link plant ecophysiology to ecosystem functioning can be identified for both research communities, promising complementarity and synergism for joint research projects. Although some well-established ecophysiological relationships, such as light responses or stomatal limitations of photosynthetic gas exchange, are currently employed in many ecosystem-scale net flux studies for gap-filling or modeling, only 14% (n = 27) of all eddy covariance flux studies in forests (n = 196; published between 1992 and April 2002) include plant ecophysiological measurements (n = 24) or biomass and growth estimates (n = 8). Generally, emphasis is on CO2 exchange measurements at various scales (foliage, shoots, branches; n = 14) and water relations measurements (n = 11). These measurements do not fully support the typical parameterization of stand and regional models, which often need information on canopy architecture and nitrogen nutrition. By means of a complementary research approach, valuable information can be acquired that is unobtainable by means of a single approach. This additional information is important for the identification of underlying biotic and environmental drivers, for the regulation of net ecosystem fluxes and their partitioning, and the independent validation of measured net ecosystem fluxes. Thus, combining micrometeorology and ecophysiology at flux sites is strongly recommended for ecosystem functioning studies.

  7. Strain-specific functional and numerical responses are required to evaluate impacts on predator-prey dynamics.

    PubMed

    Yang, Zhou; Lowe, Chris D; Crowther, Will; Fenton, Andy; Watts, Phillip C; Montagnes, David J S

    2013-02-01

    We use strains recently collected from the field to establish cultures; then, through laboratory studies we investigate how among strain variation in protozoan ingestion and growth rates influences population dynamics and intraspecific competition. We focused on the impact of changing temperature because of its well-established effects on protozoan rates and its ecological relevance, from daily fluctuations to climate change. We show, first, that there is considerable inter-strain variability in thermal sensitivity of maximum growth rate, revealing distinct differences among multiple strains of our model species Oxyrrhis marina. We then intensively examined two representative strains that exhibit distinctly different thermal responses and parameterised the influence of temperature on their functional and numerical responses. Finally, we assessed how these responses alter predator-prey population dynamics. We do this first considering a standard approach, which assumes that functional and numerical responses are directly coupled, and then compare these results with a novel framework that incorporates both functional and numerical responses in a fully parameterised model. We conclude that: (i) including functional diversity of protozoa at the sub-species level will alter model predictions and (ii) including directly measured, independent functional and numerical responses in a model can provide a more realistic account of predator-prey dynamics.

  8. Self-report measures, facial feedback, and personality differences (BEES) in cooperative vs. noncooperative situations: contribution of the mimic system to the sense of empathy.

    PubMed

    Balconi, Michela; Bortolotti, Adriana; Crivelli, Davide

    2013-01-01

    The present study integrated three different measures of emotional empathic behavior in a social context: verbal self-report measures (empathic response, emotional involvement, emotional significance, and valence), facial mimicry (activity of corrugator and zygomaticus muscles), and personal response to the Balanced Emotional Empathy Scale (BEES). Participants were presented with different interpersonal scene types (cooperation, noncooperation, conflict, indifference). Firstly, self-rating on empathy, emotional involvement, and valence varied as a function of interpersonal context. Secondly, corrugator activity increased in response to conflictual and noncooperative situations; zygomatic activity increased in response to cooperative situations. Third, high- and low-BEES subjects showed different empathic behavior: High-empathic subjects were more responsive to empathy-related situations than low-empathic subjects. The convergence and divergence of these multidimensional measures was discussed.

  9. Catecholamines and cognition after traumatic brain injury

    PubMed Central

    Jenkins, Peter O.; Mehta, Mitul A.

    2016-01-01

    Abstract Cognitive problems are one of the main causes of ongoing disability after traumatic brain injury. The heterogeneity of the injuries sustained and the variability of the resulting cognitive deficits makes treating these problems difficult. Identifying the underlying pathology allows a targeted treatment approach aimed at cognitive enhancement. For example, damage to neuromodulatory neurotransmitter systems is common after traumatic brain injury and is an important cause of cognitive impairment. Here, we discuss the evidence implicating disruption of the catecholamines (dopamine and noradrenaline) and review the efficacy of catecholaminergic drugs in treating post-traumatic brain injury cognitive impairments. The response to these therapies is often variable, a likely consequence of the heterogeneous patterns of injury as well as a non-linear relationship between catecholamine levels and cognitive functions. This individual variability means that measuring the structure and function of a person’s catecholaminergic systems is likely to allow more refined therapy. Advanced structural and molecular imaging techniques offer the potential to identify disruption to the catecholaminergic systems and to provide a direct measure of catecholamine levels. In addition, measures of structural and functional connectivity can be used to identify common patterns of injury and to measure the functioning of brain ‘networks’ that are important for normal cognitive functioning. As the catecholamine systems modulate these cognitive networks, these measures could potentially be used to stratify treatment selection and monitor response to treatment in a more sophisticated manner. PMID:27256296

  10. A unified method for evaluating real-time computer controllers: A case study. [aircraft control

    NASA Technical Reports Server (NTRS)

    Shin, K. G.; Krishna, C. M.; Lee, Y. H.

    1982-01-01

    A real time control system consists of a synergistic pair, that is, a controlled process and a controller computer. Performance measures for real time controller computers are defined on the basis of the nature of this synergistic pair. A case study of a typical critical controlled process is presented in the context of new performance measures that express the performance of both controlled processes and real time controllers (taken as a unit) on the basis of a single variable: controller response time. Controller response time is a function of current system state, system failure rate, electrical and/or magnetic interference, etc., and is therefore a random variable. Control overhead is expressed as a monotonically nondecreasing function of the response time and the system suffers catastrophic failure, or dynamic failure, if the response time for a control task exceeds the corresponding system hard deadline, if any. A rigorous probabilistic approach is used to estimate the performance measures. The controlled process chosen for study is an aircraft in the final stages of descent, just prior to landing. First, the performance measures for the controller are presented. Secondly, control algorithms for solving the landing problem are discussed and finally the impact of the performance measures on the problem is analyzed.

  11. Design and analysis of fractional order seismic transducer for displacement and acceleration measurements

    NASA Astrophysics Data System (ADS)

    Veeraian, Parthasarathi; Gandhi, Uma; Mangalanathan, Umapathy

    2018-04-01

    Seismic transducers are widely used for measurement of displacement, velocity, and acceleration. This paper presents the design of seismic transducer in the fractional domain for the measurement of displacement and acceleration. The fractional order transfer function for seismic displacement and acceleration transducer are derived using Grünwald-Letnikov derivative. Frequency response analysis of fractional order seismic displacement transducer (FOSDT) and fractional order seismic acceleration transducer (FOSAT) are carried out for different damping ratio with the different fractional order, and the maximum dynamic measurement range is identified. The results demonstrate that fractional order seismic transducer has increased dynamic measurement range and less phase distortion as compared to the conventional seismic transducer even with a lower damping ratio. Time response of FOSDT and FOSAT are derived analytically in terms of Mittag-Leffler function, the effect of fractional behavior in the time domain is evaluated from the impulse and step response. The fractional order system is found to have significantly reduced overshoot as compared to the conventional transducer. The fractional order seismic transducer design proposed in this paper is illustrated with a design example for FOSDT and FOSAT. Finally, an electrical equivalent of FOSDT and FOSAT is considered, and its frequency response is found to be in close agreement with the proposed fractional order seismic transducer.

  12. Comparison of dose response functions for EBT3 model GafChromic™ film dosimetry system.

    PubMed

    Aldelaijan, Saad; Devic, Slobodan

    2018-05-01

    Different dose response functions of EBT3 model GafChromic™ film dosimetry system have been compared in terms of sensitivity as well as uncertainty vs. error analysis. We also made an assessment of the necessity of scanning film pieces before and after irradiation. Pieces of EBT3 film model were irradiated to different dose values in Solid Water (SW) phantom. Based on images scanned in both reflection and transmission mode before and after irradiation, twelve different response functions were calculated. For every response function, a reference radiochromic film dosimetry system was established by generating calibration curve and by performing the error vs. uncertainty analysis. Response functions using pixel values from the green channel demonstrated the highest sensitivity in both transmission and reflection mode. All functions were successfully fitted with rational functional form, and provided an overall one-sigma uncertainty of better than 2% for doses above 2 Gy. Use of pre-scanned images to calculate response functions resulted in negligible improvement in dose measurement accuracy. Although reflection scanning mode provides higher sensitivity and could lead to a more widespread use of radiochromic film dosimetry, it has fairly limited dose range and slightly increased uncertainty when compared to transmission scan based response functions. Double-scanning technique, either in transmission or reflection mode, shows negligible improvement in dose accuracy as well as a negligible increase in dose uncertainty. Normalized pixel value of the images scanned in transmission mode shows linear response in a dose range of up to 11 Gy. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  13. An item response theory analysis of the Executive Interview and development of the EXIT8: A Project FRONTIER Study.

    PubMed

    Jahn, Danielle R; Dressel, Jeffrey A; Gavett, Brandon E; O'Bryant, Sid E

    2015-01-01

    The Executive Interview (EXIT25) is an effective measure of executive dysfunction, but may be inefficient due to the time it takes to complete 25 interview-based items. The current study aimed to examine psychometric properties of the EXIT25, with a specific focus on determining whether a briefer version of the measure could comprehensively assess executive dysfunction. The current study applied a graded response model (a type of item response theory model for polytomous categorical data) to identify items that were most closely related to the underlying construct of executive functioning and best discriminated between varying levels of executive functioning. Participants were 660 adults ages 40 to 96 years living in West Texas, who were recruited through an ongoing epidemiological study of rural health and aging, called Project FRONTIER. The EXIT25 was the primary measure examined. Participants also completed the Trail Making Test and Controlled Oral Word Association Test, among other measures, to examine the convergent validity of a brief form of the EXIT25. Eight items were identified that provided the majority of the information about the underlying construct of executive functioning; total scores on these items were associated with total scores on other measures of executive functioning and were able to differentiate between cognitively healthy, mildly cognitively impaired, and demented participants. In addition, cutoff scores were recommended based on sensitivity and specificity of scores. A brief, eight-item version of the EXIT25 may be an effective and efficient screening for executive dysfunction among older adults.

  14. The patient-specific functional scale: psychometrics, clinimetrics, and application as a clinical outcome measure.

    PubMed

    Horn, Katyana Kowalchuk; Jennings, Sophie; Richardson, Gillian; Vliet, Ditte Van; Hefford, Cheryl; Abbott, J Haxby

    2012-01-01

    Systematic review of the literature. To summarize peer-reviewed literature on the reliability, validity, and responsiveness of the Patient-Specific Functional Scale (PSFS), and to identify its use as an outcome measure. Searches were performed of several electronic databases from 1995 to May 2010. Studies included were published articles containing (1) primary research investigating the psychometric and clinimetrics of the PSFS or (2) the implementation of the PSFS as an outcome measure. We assessed the methodological quality of studies included in the first category. Two hundred forty-two articles published from 1994 to May 2010 were identified. Of these, 66 met the inclusion criteria for this review, with 13 reporting the measurement properties of the PSFS, 55 implementing the PSFS as an outcome measure, and 2 doing both of the above. The PSFS was reported to be valid, reliable, and responsive in populations with knee dysfunction, cervical radiculopathy, acute low back pain, mechanical low back pain, and neck dysfunction. The PSFS was found to be reliable and responsive in populations with chronic low back pain. The PSFS was also reported to be valid, reliable, or responsive in individuals with a limited number of acute, subacute, and chronic conditions. This review found that the PSFS is also being used as an outcome measure in many other conditions, despite a lack of published evidence supporting its validity in these conditions. Although the use of the PSFS as an outcome measure is increasing in physiotherapy practice, there are gaps in the research literature regarding its validity, reliability, and responsiveness in many health conditions.

  15. Left ventricular, systemic arterial, and baroreflex responses to ketamine and TEE in chronically instrumented monkeys

    NASA Technical Reports Server (NTRS)

    Koenig, S. C.; Ludwig, D. A.; Reister, C.; Fanton, J. W.; Ewert, D.; Convertino, V. A.

    2001-01-01

    Effects of prescribed doses of ketamine five minutes after application and influences of transesophageal echocardiography (TEE) on left ventricular, systemic arterial, and baroreflex responses were investigated to test the hypothesis that ketamine and/or TEE probe insertion alter cardiovascular function. Seven rhesus monkeys were tested under each of four randomly selected experimental conditions: (1) intravenous bolus dose of ketamine (0.5 ml), (2) continuous infusion of ketamine (500 mg/kg/min), (3) continuous infusion of ketamine (500 mg/kg/min) with TEE, and (4) control (no ketamine or TEE). Monkeys were chronically instrumented with a high fidelity, dual-sensor micromanometer to measure left ventricular and aortic pressure and a transit-time ultrasound probe to measure aortic flow. These measures were used to calculate left ventricular function. A 4-element Windkessel lumped-parameter model was used to estimate total peripheral resistance and systemic arterial compliance. Baroreflex response was calculated as the change in R-R interval divided by the change in mean aortic pressure measured during administration of graded concentrations of nitroprusside. The results indicated that five minutes after ketamine application heart rate and left ventricular diastolic compliance decreased while TEE increased aortic systolic and diastolic pressure. We conclude that ketamine may be administered as either a bolus or continuous infusion without affecting cardiovascular function 5 minutes after application while the insertion of a TEE probe will increase aortic pressure. The results for both ketamine and TEE illustrate the classic "Hawthorne Effect," where the observed values are partly a function of the measurement process. Measures of aortic pressure, heart rate, and left ventricular diastolic pressure should be viewed as relative, as opposed to absolute, when organisms are sedated with ketamine or instrumented with a TEE probe.

  16. Closed-loop spontaneous baroreflex transfer function is inappropriate for system identification of neural arc but partly accurate for peripheral arc: predictability analysis

    PubMed Central

    Kamiya, Atsunori; Kawada, Toru; Shimizu, Shuji; Sugimachi, Masaru

    2011-01-01

    Abstract Although the dynamic characteristics of the baroreflex system have been described by baroreflex transfer functions obtained from open-loop analysis, the predictability of time-series output dynamics from input signals, which should confirm the accuracy of system identification, remains to be elucidated. Moreover, despite theoretical concerns over closed-loop system identification, the accuracy and the predictability of the closed-loop spontaneous baroreflex transfer function have not been evaluated compared with the open-loop transfer function. Using urethane and α-chloralose anaesthetized, vagotomized and aortic-denervated rabbits (n = 10), we identified open-loop baroreflex transfer functions by recording renal sympathetic nerve activity (SNA) while varying the vascularly isolated intracarotid sinus pressure (CSP) according to a binary random (white-noise) sequence (operating pressure ± 20 mmHg), and using a simplified equation to calculate closed-loop-spontaneous baroreflex transfer function while matching CSP with systemic arterial pressure (AP). Our results showed that the open-loop baroreflex transfer functions for the neural and peripheral arcs predicted the time-series SNA and AP outputs from measured CSP and SNA inputs, with r2 of 0.8 ± 0.1 and 0.8 ± 0.1, respectively. In contrast, the closed-loop-spontaneous baroreflex transfer function for the neural arc was markedly different from the open-loop transfer function (enhanced gain increase and a phase lead), and did not predict the time-series SNA dynamics (r2; 0.1 ± 0.1). However, the closed-loop-spontaneous baroreflex transfer function of the peripheral arc partially matched the open-loop transfer function in gain and phase functions, and had limited but reasonable predictability of the time-series AP dynamics (r2, 0.7 ± 0.1). A numerical simulation suggested that a noise predominantly in the neural arc under resting conditions might be a possible mechanism responsible for our findings. Furthermore, the predictabilities of the neural arc transfer functions obtained in open-loop and closed-loop conditions were validated by closed-loop pharmacological (phenylephrine and nitroprusside infusions) pressure interventions. Time-series SNA responses to drug-induced AP changes predicted by the open-loop transfer function matched closely the measured responses (r2, 0.9 ± 0.1), whereas SNA responses predicted by closed-loop-spontaneous transfer function deviated greatly and were the inverse of measured responses (r, −0.8 ± 0.2). These results indicate that although the spontaneous baroreflex transfer function obtained by closed-loop analysis has been believed to represent the neural arc function, it is inappropriate for system identification of the neural arc but is essentially appropriate for the peripheral arc under resting conditions, when compared with open-loop analysis. PMID:21486839

  17. Effect of Reinforcer Magnitude on Performance Maintained by Progressive-Ratio Schedules

    PubMed Central

    Rickard, J.F; Body, S; Zhang, Z; Bradshaw, C.M; Szabadi, E

    2009-01-01

    This experiment examined the relationship between reinforcer magnitude and quantitative measures of performance on progressive-ratio schedules. Fifteen rats were trained under a progressive-ratio schedule in seven phases of the experiment in which the volume of a 0.6-M sucrose solution reinforcer was varied within the range 6–300 µl. Overall response rates in successive ratios conformed to a bitonic equation derived from Killeen's (1994) Mathematical Principles of Reinforcement. The “specific activation” parameter, a, which is presumed to reflect the incentive value of the reinforcer, was a monotonically increasing function of reinforcer volume; the “response time” parameter, δ, which defines the minimum response time, increased as a function of reinforcer volume; the “currency” parameter, β, which is presumed to reflect the coupling of responses to the reinforcer, declined as a function of volume. Running response rate (response rate calculated after exclusion of the postreinforcement pause) decayed monotonically as a function of ratio size; the index of curvature of this function increased as a function of reinforcer volume. Postreinforcement pause increased as a function of ratio size. Estimates of a derived from overall response rates and postreinforcement pauses showed a modest positive correlation across conditions and between animals. Implications of the results for the quantification of reinforcer value and for the use of progressive-ratio schedules in behavioral neuroscience are discussed. PMID:19230513

  18. Effect of reinforcer magnitude on performance maintained by progressive-ratio schedules.

    PubMed

    Rickard, J F; Body, S; Zhang, Z; Bradshaw, C M; Szabadi, E

    2009-01-01

    This experiment examined the relationship between reinforcer magnitude and quantitative measures of performance on progressive-ratio schedules. Fifteen rats were trained under a progressive-ratio schedule in seven phases of the experiment in which the volume of a 0.6-M sucrose solution reinforcer was varied within the range 6-300 microl. Overall response rates in successive ratios conformed to a bitonic equation derived from Killeen's (1994) Mathematical Principles of Reinforcement. The "specific activation" parameter, a, which is presumed to reflect the incentive value of the reinforcer, was a monotonically increasing function of reinforcer volume; the "response time" parameter, delta, which defines the minimum response time, increased as a function of reinforcer volume; the "currency" parameter, beta, which is presumed to reflect the coupling of responses to the reinforcer, declined as a function of volume. Running response rate (response rate calculated after exclusion of the postreinforcement pause) decayed monotonically as a function of ratio size; the index of curvature of this function increased as a function of reinforcer volume. Postreinforcement pause increased as a function of ratio size. Estimates of a derived from overall response rates and postreinforcement pauses showed a modest positive correlation across conditions and between animals. Implications of the results for the quantification of reinforcer value and for the use of progressive-ratio schedules in behavioral neuroscience are discussed.

  19. Visuocortical Function in Infants With a History of Neonatal Jaundice

    PubMed Central

    Hou, Chuan; Norcia, Anthony M.; Madan, Ashima; Good, William V.

    2014-01-01

    Purpose. High concentrations of unconjugated bilirubin are neurotoxic and cause brain damage in newborn infants. However, the exact level of bilirubin that may be neurotoxic in a given infant is unknown. The aim of this study was to use a quantitative measure of neural activity, the swept parameter visual evoked potential (sVEP) to determine the relationship between neonatal bilirubin levels and visual responsivity several months later. Methods. We compared sVEP response functions over a wide range of contrast, spatial frequency, and Vernier offset sizes in 16 full-term infants with high bilirubin levels (>10 mg/dL) and 18 age-matched infants with no visible neonatal jaundice, all enrolled at 14 to 22 weeks of age. The group means of sVEP thresholds and suprathreshold response amplitudes were compared. The correlation between individual sVEP thresholds and bilirubin levels in jaundiced infants was studied. Results. Infants who had a history of neonatal jaundice showed lower response amplitudes (P < 0.05) and worse or immeasurable sVEP thresholds compared with control infants for all three measures (P < 0.05). Swept parameter visual evoked potential thresholds for Vernier offset were correlated with bilirubin level (P < 0.05), but spatial acuity and contrast sensitivity measures in the infants with neonatal jaundice were not (P > 0.05). Conclusions. These results indicate that elevated neonatal bilirubin levels affect measures of visual function in infancy up to at least 14 to 22 weeks of postnatal age. PMID:25183760

  20. Combining agreement and frequency rating scales to optimize psychometrics in measuring behavioral health functioning.

    PubMed

    Marfeo, Elizabeth E; Ni, Pengsheng; Chan, Leighton; Rasch, Elizabeth K; Jette, Alan M

    2014-07-01

    The goal of this article was to investigate optimal functioning of using frequency vs. agreement rating scales in two subdomains of the newly developed Work Disability Functional Assessment Battery: the Mood & Emotions and Behavioral Control scales. A psychometric study comparing rating scale performance embedded in a cross-sectional survey used for developing a new instrument to measure behavioral health functioning among adults applying for disability benefits in the United States was performed. Within the sample of 1,017 respondents, the range of response category endorsement was similar for both frequency and agreement item types for both scales. There were fewer missing values in the frequency items than the agreement items. Both frequency and agreement items showed acceptable reliability. The frequency items demonstrated optimal effectiveness around the mean ± 1-2 standard deviation score range; the agreement items performed better at the extreme score ranges. Findings suggest an optimal response format requires a mix of both agreement-based and frequency-based items. Frequency items perform better in the normal range of responses, capturing specific behaviors, reactions, or situations that may elicit a specific response. Agreement items do better for those whose scores are more extreme and capture subjective content related to general attitudes, behaviors, or feelings of work-related behavioral health functioning. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. SU-E-T-299: Small Fields Profiles Correction Through Detectors Spatial Response Functions and Field Size Dependence Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Filipuzzi, M; Garrigo, E; Venencia, C

    2014-06-01

    Purpose: To calculate the spatial response function of various radiation detectors, to evaluate the dependence on the field size and to analyze the small fields profiles corrections by deconvolution techniques. Methods: Crossline profiles were measured on a Novalis Tx 6MV beam with a HDMLC. The configuration setup was SSD=100cm and depth=5cm. Five fields were studied (200×200mm2,100×100mm2, 20×20mm2, 10×10mm2and 5×5mm2) and measured were made with passive detectors (EBT3 radiochromic films and TLD700 thermoluminescent detectors), ionization chambers (PTW30013, PTW31003, CC04 and PTW31016) and diodes (PTW60012 and IBA SFD). The results of passive detectors were adopted as the actual beam profile. To calculatemore » the detectors kernels, modeled by Gaussian functions, an iterative process based on a least squares criterion was used. The deconvolutions of the measured profiles were calculated with the Richardson-Lucy method. Results: The profiles of the passive detectors corresponded with a difference in the penumbra less than 0.1mm. Both diodes resolve the profiles with an overestimation of the penumbra smaller than 0.2mm. For the other detectors, response functions were calculated and resulted in Gaussian functions with a standard deviation approximate to the radius of the detector in study (with a variation less than 3%). The corrected profiles resolve the penumbra with less than 1% error. Major discrepancies were observed for cases in extreme conditions (PTW31003 and 5×5mm2 field size). Conclusion: This work concludes that the response function of a radiation detector is independent on the field size, even for small radiation beams. The profiles correction, using deconvolution techniques and response functions of standard deviation equal to the radius of the detector, gives penumbra values with less than 1% difference to the real profile. The implementation of this technique allows estimating the real profile, freeing from the effects of the detector used for the acquisition.« less

  2. Does Older Adults' Cognitive Function Disrupt the Malleability of Their Attitudes toward Outgroup Members?: An fMRI Investigation.

    PubMed

    Krendl, Anne C; Kensinger, Elizabeth A

    2016-01-01

    In the current study we examine how individual differences in older adults' global cognitive function impacts the extent to which their attitudes toward stigmatized individuals are malleable. Because prior research has elucidated the neural processes that are involved in evaluating stigmatized individuals who are responsible or not responsible for their condition, a cognitive neuroscience approach may be well-suited to answer this question. In the current study, 36 older and 17 young adults underwent functional magnetic resonance imaging while evaluating images of homeless people who were described as being responsible or not responsible for their condition. They also indicated how much pity they felt for each of the individuals in order to determine the extent to which their attitudes were malleable (e.g., more pity for not-responsible as compared to responsible individuals). Participants' cognitive function and baseline measure of their attitudes toward stigmatized individuals (including homeless individuals) were assessed. Results revealed that although older adults' attitudes were malleable, the extent to which this was true varied due to individual differences in their global cognitive function. Specifically, the difference in the magnitude of older adults' self-reported pity for not-responsible as compared to responsible homeless individuals was predicted by their global cognitive function. Moreover, the difference in pity that older adults expressed toward not-responsible as compared to responsible homeless individuals was related to activity in the left insula and the anterior cingulate cortex (regions implicated in empathy). These results suggest that attitude malleability is affected by individual differences in global cognitive function.

  3. Does Older Adults’ Cognitive Function Disrupt the Malleability of Their Attitudes toward Outgroup Members?: An fMRI Investigation

    PubMed Central

    Krendl, Anne C.; Kensinger, Elizabeth A.

    2016-01-01

    In the current study we examine how individual differences in older adults’ global cognitive function impacts the extent to which their attitudes toward stigmatized individuals are malleable. Because prior research has elucidated the neural processes that are involved in evaluating stigmatized individuals who are responsible or not responsible for their condition, a cognitive neuroscience approach may be well-suited to answer this question. In the current study, 36 older and 17 young adults underwent functional magnetic resonance imaging while evaluating images of homeless people who were described as being responsible or not responsible for their condition. They also indicated how much pity they felt for each of the individuals in order to determine the extent to which their attitudes were malleable (e.g., more pity for not-responsible as compared to responsible individuals). Participants’ cognitive function and baseline measure of their attitudes toward stigmatized individuals (including homeless individuals) were assessed. Results revealed that although older adults’ attitudes were malleable, the extent to which this was true varied due to individual differences in their global cognitive function. Specifically, the difference in the magnitude of older adults’ self-reported pity for not-responsible as compared to responsible homeless individuals was predicted by their global cognitive function. Moreover, the difference in pity that older adults expressed toward not-responsible as compared to responsible homeless individuals was related to activity in the left insula and the anterior cingulate cortex (regions implicated in empathy). These results suggest that attitude malleability is affected by individual differences in global cognitive function. PMID:27074046

  4. Extension of the Contingency Naming Test to adult assessment: psychometric analysis in a college student sample.

    PubMed

    Riddle, Tara; Suhr, Julie

    2012-01-01

    The Contingency Naming Test (CNT; Taylor, Albo, Phebus, Sachs, & Bierl, 1987) was initially designed to assess aspects of executive functioning, such as processing speed and response inhibition, in children. The measure has shown initial utility in identifying differences in executive function among child clinical groups; however, there is an absence of adequate psychometric data for use with adults. The current study expanded psychometric data upward for use with a college student sample and explored the measure's test-retest reliability and factor structure. Performance in the adult sample showed continued improvement above child norms, consistent with theories of executive function development. Exploratory factor analysis showed that the CNT is most closely related to measures of processing speed, as well as elements of response inhibition within the latter trials. Overall, results from the current study provide added support for the utility of the CNT as a measure of executive functioning in young adults. However, more research is needed to determine patterns of performance among adult clinical groups, as well as to better understand how performance patterns may change in a broader age range, including middle and older adulthood.

  5. Effects of microgravity on vestibular ontogeny: direct physiological and anatomical measurements following space flight (STS-29)

    NASA Technical Reports Server (NTRS)

    Jones, T. A.; Fermin, C.; Hester, P. Y.; Vellinger, J.

    1993-01-01

    Does space flight change gravity receptor development? The present study measured vestibular form and function in birds flown as embryos for 5 days in earth orbit (STS-29). No major changes in vestibular gross morphology were found. Vestibular response mean amplitudes and latencies were unaffected by space flight. However, the results of measuring vestibular thresholds were mixed and abnormal responses in 3 of the 8 flight animals raise important questions.

  6. Evaluation of Thermal Protection Tile Transmissibility for Ground Vibration Test

    NASA Technical Reports Server (NTRS)

    Chung, Y. T.; Fowler, Samuel B.; Lo, Wenso; Towner, Robert

    2005-01-01

    Transmissibility analyses and tests were conducted on a composite panel with thermal protection system foams to evaluate the quality of the measured frequency response functions. Both the analysis and the test results indicate that the vehicle dynamic responses are fully transmitted to the accelerometers mounted on the thermal protection system in the normal direction below a certain frequency. In addition, the in-plane motions of the accelerometer mounted on the top surface of the thermal protection system behave more actively than those on the composite panel due to the geometric offset of the accelerometer from the panel in the test set-up. The transmissibility tests and analyses show that the frequency response functions measured from the accelerometers mounted on the TPS will provide accurate vehicle responses below 120 Hz for frequency and mode shape identification. By confirming that accurate dynamic responses below a given frequency can be obtained, this study increases the confidence needed for conducting the modal testing, model correlation, and model updating for a vehicle installed with TPS. '

  7. Novel Optical Methods for Identification, Imaging, and Preservation of the Cavernous Nerves Responsible for Penile Erections during Prostate Cancer Surgery

    DTIC Science & Technology

    2009-03-01

    wavelength, pulse energy, and pulse rate) to produce strongest and most rapid erectile response as measured by intracavernosal pressure in the penis ...PC Fiber Rod Housing Optics 5-mm-ID Port Probe Handle Probe Stem Enlarged View of Probe Tip Oscilloscope FunctionGenerator Thulium Fiber Laser Shutter...rapid erectile response as measured by intracavernosal pressure (ICP) in the penis . ICP values were increased from an initial range of 30-40 mmHg

  8. Evaluation of Internal Construct Validity and Unidimensionality of the Brachial Assessment Tool, A Patient-Reported Outcome Measure for Brachial Plexus Injury.

    PubMed

    Hill, Bridget; Pallant, Julie; Williams, Gavin; Olver, John; Ferris, Scott; Bialocerkowski, Andrea

    2016-12-01

    To evaluate the internal construct validity and dimensionality of a new patient-reported outcome measure for people with traumatic brachial plexus injury (BPI) based on the International Classification of Functioning, Disability and Health definition of activity. Cross-sectional study. Outpatient clinics. Adults (age range, 18-82y) with a traumatic BPI (N=106). There were 106 people with BPI who completed a 51-item 5-response questionnaire. Responses were analyzed in 4 phases (missing responses, item correlations, exploratory factor analysis, and Rasch analysis) to evaluate the properties of fit to the Rasch model, threshold response, local dependency, dimensionality, differential item functioning, and targeting. Not applicable, as this study addresses the development of an outcome measure. Six items were deleted for missing responses, and 10 were deleted for high interitem correlations >.81. The remaining 35 items, while demonstrating fit to the Rasch model, showed evidence of local dependency and multidimensionality. Items were divided into 3 subscales: dressing and grooming (8 items), arm and hand (17 items), and no hand (6 items). All 3 subscales demonstrated fit to the model with no local dependency, minimal disordered thresholds, no unidimensionality or differential item functioning for age, time postinjury, or self-selected dominance. Subscales were combined into 3 subtests and demonstrated fit to the model, no misfit, and unidimensionality, allowing calculation of a summary score. This preliminary analysis supports the internal construct validity of the Brachial Assessment Tool, a unidimensional targeted 4-response patient-reported outcome measure designed to solely assess activity after traumatic BPI regardless of level of injury, age at recruitment, premorbid limb dominance, and time postinjury. Further examination is required to determine test-retest reliability and responsiveness. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  9. Insights into distinct modulation of α7 and α7β2 nicotinic acetylcholine receptors by the volatile anesthetic isoflurane.

    PubMed

    Mowrey, David D; Liu, Qiang; Bondarenko, Vasyl; Chen, Qiang; Seyoum, Edom; Xu, Yan; Wu, Jie; Tang, Pei

    2013-12-13

    Nicotinic acetylcholine receptors (nAChRs) are targets of general anesthetics, but functional sensitivity to anesthetic inhibition varies dramatically among different subtypes of nAChRs. Potential causes underlying different functional responses to anesthetics remain elusive. Here we show that in contrast to the α7 nAChR, the α7β2 nAChR is highly susceptible to inhibition by the volatile anesthetic isoflurane in electrophysiology measurements. Isoflurane-binding sites in β2 and α7 were found at the extracellular and intracellular end of their respective transmembrane domains using NMR. Functional relevance of the identified β2 site was validated via point mutations and subsequent functional measurements. Consistent with their functional responses to isoflurane, β2 but not α7 showed pronounced dynamics changes, particularly for the channel gate residue Leu-249(9'). These results suggest that anesthetic binding alone is not sufficient to generate functional impact; only those sites that can modulate channel dynamics upon anesthetic binding will produce functional effects.

  10. End-to-end test of the electron-proton spectrometer

    NASA Technical Reports Server (NTRS)

    Cash, B. L.

    1972-01-01

    A series of end-to-end tests were performed to demonstrate the proper functioning of the complete Electron-Proton Spectrometer (EPS). The purpose of the tests was to provide experimental verification of the design and to provide a complete functional performance check of the instrument from the excitation of the sensors to and including the data processor and equipment test set. Each of the channels of the EPS was exposed to a calibrated beam of energetic particles, and counts were accumulated for a predetermined period of time for each of several energies. The counts were related to the known flux of particles to give a monodirectional response function for each channel. The measured response function of the test unit was compared to the response function determined for the calibration sensors from the data taken from the calibration program.

  11. Virological outcome after structured interruption of antiretroviral therapy for human immunodeficiency virus infection is associated with the functional profile of virus-specific CD8+ T cells.

    PubMed

    Daucher, Marybeth; Price, David A; Brenchley, Jason M; Lamoreaux, Laurie; Metcalf, Julia A; Rehm, Catherine; Nies-Kraske, Elizabeth; Urban, Elizabeth; Yoder, Christian; Rock, Diane; Gumkowski, Julie; Betts, Michael R; Dybul, Mark R; Douek, Daniel C

    2008-04-01

    A clear understanding of the antiviral effects of CD8(+) T cells in the context of chronic human immunodeficiency virus (HIV) infection is critical for the development of prophylactic vaccines and therapeutics designed to support T-cell-mediated immunity. However, defining the potential correlates of effective CD8(+) T-cell immunity has proven difficult; notably, comprehensive analyses have demonstrated that the size and shape of the CD8(+) T-cell response are not necessarily indicative of efficacy determined by measures of plasma viral load. Here, we conducted a detailed quantitative and qualitative analysis of CD8(+) T-cell responses to autologous virus in a cohort of six HIV-infected individuals with a history of structured interruption of antiretroviral therapy (ART) (SIT). The magnitude and breadth of the HIV-specific response did not, by themselves, explain the changes observed in plasma virus levels after the cessation of ART. Furthermore, mutational escape from targeted epitopes could not account for the differential virological outcomes in this cohort. However, the functionality of HIV-specific CD8(+) T-cell populations upon antigen encounter, determined by the simultaneous and independent measurement of five CD8(+) T-cell functions (degranulation and gamma interferon, macrophage inflammatory protein 1beta, tumor necrosis factor alpha, and interleukin-2 levels) reflected the emergent level of plasma virus, with multiple functions being elicited in those individuals with lower levels of viremia after SIT. These data show that the quality of the HIV-specific CD8(+) T-cell response, rather than the quantity, is associated with the dynamics of viral replication in the absence of ART and suggest that the effects of SIT can be assessed by measuring the functional profile of HIV-specific CD8(+) T cells.

  12. The Melanopic Sensitivity Function Accounts for Melanopsin-Driven Responses in Mice under Diverse Lighting Conditions

    PubMed Central

    Brown, Timothy M.; Allen, Annette E.; al-Enezi, Jazi; Wynne, Jonathan; Schlangen, Luc; Hommes, Vanja; Lucas, Robert J.

    2013-01-01

    In addition to rods and cones, photoreception in mammals extends to a third retinal cell type expressing the photopigment melanopsin. The influences of this novel opsin are widespread, ranging from pupillary and circadian responses to brightness perception, yet established approaches to quantifying the biological effects of light do not adequately account for melanopsin sensitivity. We have recently proposed a novel metric, the melanopic sensitivity function (VZλ), to address this deficiency. Here, we further validate this new measure with a variety of tests based on potential barriers to its applicability identified in the literature or relating to obvious practical benefits. Using electrophysiogical approaches and pupillometry, initially in rodless+coneless mice, our data demonstrate that under a very wide range of different conditions (including switching between stimuli with highly divergent spectral content) the VZλ function provides an accurate prediction of the sensitivity of melanopsin-dependent responses. We further show that VZλ provides the best available description of the spectral sensitivity of at least one aspect of the visual response in mice with functional rods and cones: tonic firing activity in the lateral geniculate nuclei. Together, these data establish VZλ as an important new approach for light measurement with widespread practical utility. PMID:23301090

  13. Using the Rasch Measurement Model in Psychometric Analysis of the Family Effectiveness Measure

    PubMed Central

    McCreary, Linda L.; Conrad, Karen M.; Conrad, Kendon J.; Scott, Christy K; Funk, Rodney R.; Dennis, Michael L.

    2013-01-01

    Background Valid assessment of family functioning can play a vital role in optimizing client outcomes. Because family functioning is influenced by family structure, socioeconomic context, and culture, existing measures of family functioning--primarily developed with nuclear, middle class European American families--may not be valid assessments of families in diverse populations. The Family Effectiveness Measure was developed to address this limitation. Objectives To test the Family Effectiveness Measure with data from a primarily low-income African American convenience sample, using the Rasch measurement model. Method A sample of 607 adult women completed the measure. Rasch analysis was used to assess unidimensionality, response category functioning, item fit, person reliability, differential item functioning by race and parental status, and item hierarchy. Criterion-related validity was tested using correlations with five other variables related to family functioning. Results The Family Effectiveness Measure measures two separate constructs: The effective family functioning construct was a psychometrically sound measure of the target construct that was more efficient due to the deletion of 22 items. The ineffective family functioning construct consisted of 16 of those deleted items but was not as strong psychometrically. Items in both constructs evidenced no differential item functioning by race. Criterion-related validity was supported for both. Discussion In contrast to the prevailing conceptualization that family functioning is a single construct, assessed by positively and negatively worded items, use of the Rasch analysis suggested the existence of two constructs. While the effective family functioning is a strong and efficient measure of family functioning, the ineffective family functioning will require additional item development and psychometric testing. PMID:23636342

  14. Pressor response to intravenous tyramine is a marker of cardiac, but not vascular, adrenergic function

    NASA Technical Reports Server (NTRS)

    Meck, Janice V.; Martin, David S.; D'Aunno, Dominick S.; Waters, Wendy W.

    2003-01-01

    Intravenous injections of the indirect sympathetic amine, tyramine, are used as a test of peripheral adrenergic function. The authors measured the time course of increases in ejection fraction, heart rate, systolic and diastolic pressure, popliteal artery flow, and greater saphenous vein diameter before and after an injection of 4.0 mg/m(2) body surface area of tyramine in normal human subjects. The tyramine caused moderate, significant increases in systolic pressure and significant decreases in total peripheral resistance. The earliest changes were a 30% increase in ejection fraction and a 16% increase in systolic pressure, followed by a 60% increase in popliteal artery flow and a later 11% increase in greater saphenous vein diameter. There were no changes in diastolic pressure or heart rate. These results suggest that pressor responses during tyramine injections are primarily due to an inotropic response that increases cardiac output and pressure and causes a reflex decrease in vascular resistance. Thus, tyramine pressor tests are a measure of cardiac, but not vascular, sympathetic function.

  15. Basilar-membrane responses to broadband noise modeled using linear filters with rational transfer functions.

    PubMed

    Recio-Spinoso, Alberto; Fan, Yun-Hui; Ruggero, Mario A

    2011-05-01

    Basilar-membrane responses to white Gaussian noise were recorded using laser velocimetry at basal sites of the chinchilla cochlea with characteristic frequencies near 10 kHz and first-order Wiener kernels were computed by cross correlation of the stimuli and the responses. The presence or absence of minimum-phase behavior was explored by fitting the kernels with discrete linear filters with rational transfer functions. Excellent fits to the kernels were obtained with filters with transfer functions including zeroes located outside the unit circle, implying nonminimum-phase behavior. These filters accurately predicted basilar-membrane responses to other noise stimuli presented at the same level as the stimulus for the kernel computation. Fits with all-pole and other minimum-phase discrete filters were inferior to fits with nonminimum-phase filters. Minimum-phase functions predicted from the amplitude functions of the Wiener kernels by Hilbert transforms were different from the measured phase curves. These results, which suggest that basilar-membrane responses do not have the minimum-phase property, challenge the validity of models of cochlear processing, which incorporate minimum-phase behavior. © 2011 IEEE

  16. Detectability of auditory signals presented without defined observation intervals

    NASA Technical Reports Server (NTRS)

    Watson, C. S.; Nichols, T. L.

    1976-01-01

    Ability to detect tones in noise was measured without defined observation intervals. Latency density functions were estimated for the first response following a signal and, separately, for the first response following randomly distributed instances of background noise. Detection performance was measured by the maximum separation between the cumulative latency density functions for signal-plus-noise and for noise alone. Values of the index of detectability, estimated by this procedure, were approximately those obtained with a 2-dB weaker signal and defined observation intervals. Simulation of defined- and non-defined-interval tasks with an energy detector showed that this device performs very similarly to the human listener in both cases.

  17. The response to sulpiride in social anxiety disorder: D2 receptor function.

    PubMed

    Bell, Caroline; Bhikha, Shamina; Colhoun, Helen; Carter, Frances; Frampton, Chris; Porter, Richard

    2013-02-01

    Some previous studies have suggested that patients with social anxiety disorder (SAD) have a hypoactive central dopaminergic system. Supporting this there have been reports from neuroimaging studies of reduced striatal D2 receptor binding in subjects with SAD. The aim of this study was to investigate D2 receptor sensitivity in patients with SAD compared with a group of matched, healthy controls using a neuroendocrine challenge with the selective D2 antagonist, sulpiride. D2 receptor function was assessed in 23 subjects with generalized SAD and 23 matched, healthy controls using a challenge with 400 mg of a selective D2 antagonist, sulpiride in a randomized, placebo-controlled, crossover design. Response to sulpiride was measured by the change in prolactin level and changes in self-rated measures of social anxiety, mood and the ability to experience pleasure. There was no significant difference in prolactin response to sulpiride between the two groups. Sulpiride resulted in no effect in either the SAD or healthy control group on measures of social anxiety, mood or the ability to experience pleasure. Contrary to our hypothesis, in this study we found no evidence of reduced D2 receptor function in subjects with SAD compared with healthy controls.

  18. Differential item functioning analysis of the Vanderbilt Expertise Test for cars.

    PubMed

    Lee, Woo-Yeol; Cho, Sun-Joo; McGugin, Rankin W; Van Gulick, Ana Beth; Gauthier, Isabel

    2015-01-01

    The Vanderbilt Expertise Test for cars (VETcar) is a test of visual learning for contemporary car models. We used item response theory to assess the VETcar and in particular used differential item functioning (DIF) analysis to ask if the test functions the same way in laboratory versus online settings and for different groups based on age and gender. An exploratory factor analysis found evidence of multidimensionality in the VETcar, although a single dimension was deemed sufficient to capture the recognition ability measured by the test. We selected a unidimensional three-parameter logistic item response model to examine item characteristics and subject abilities. The VETcar had satisfactory internal consistency. A substantial number of items showed DIF at a medium effect size for test setting and for age group, whereas gender DIF was negligible. Because online subjects were on average older than those tested in the lab, we focused on the age groups to conduct a multigroup item response theory analysis. This revealed that most items on the test favored the younger group. DIF could be more the rule than the exception when measuring performance with familiar object categories, therefore posing a challenge for the measurement of either domain-general visual abilities or category-specific knowledge.

  19. Enhancing photoresponsivity using MoTe2-graphene vertical heterostructures

    NASA Astrophysics Data System (ADS)

    Kuiri, Manabendra; Chakraborty, Biswanath; Paul, Arup; Das, Subhadip; Sood, A. K.; Das, Anindya

    2016-02-01

    MoTe2 with a narrow band-gap of ˜1.1 eV is a promising candidate for optoelectronic applications, especially for the near-infrared photo detection. However, the photo responsivity of few layers MoTe2 is very small (<1 mA W-1). In this work, we show that a few layer MoTe2-graphene vertical heterostructures have a much larger photo responsivity of ˜20 mA W-1. The trans-conductance measurements with back gate voltage show on-off ratio of the vertical transistor to be ˜(0.5-1) × 105. The rectification nature of the source-drain current with the back gate voltage reveals the presence of a stronger Schottky barrier at the MoTe2-metal contact as compared to the MoTe2-graphene interface. In order to quantify the barrier height, it is essential to measure the work function of a few layers MoTe2, not known so far. We demonstrate a method to determine the work function by measuring the photo-response of the vertical transistor as a function of the Schottky barrier height at the MoTe2-graphene interface tuned by electrolytic top gating.

  20. The association between cognitive deficits and prefrontal hemodynamic responses during performance of working memory task in patients with schizophrenia.

    PubMed

    Pu, Shenghong; Nakagome, Kazuyuki; Itakura, Masashi; Iwata, Masaaki; Nagata, Izumi; Kaneko, Koichi

    2016-04-01

    Schizophrenia-associated cognitive deficits are resistant to treatment and thus pose a lifelong burden. The Brief Assessment of Cognition in Schizophrenia (BACS) provides reliable and valid assessments across cognitive domains. However, because the prefrontal functional abnormalities specifically associated with the level of cognitive deficits in schizophrenia have not been examined, we explored this relationship. Patients with schizophrenia (N=87) and matched healthy controls (N=50) participated in the study. Using near-infrared spectroscopy (NIRS), we measured the hemodynamic responses in the prefrontal and superior temporal cortical surface areas during a working memory task. Correlation analyses revealed a relationship between the hemodynamics and the BACS composite and domain scores. Hemodynamic responses of the left dorsolateral prefrontal cortex (DLPFC) and left frontopolar cortex (FPC) in the higher-level-of-cognitive-function schizophrenia group were weaker than the responses of the controls but similar to those of the lower-level-of-cognitive-function schizophrenia group. However, hemodynamic responses in the right DLPFC, bilateral ventrolateral PFC (VLPFC), and right temporal regions decreased with increasing cognitive deficits. In addition, the hemodynamic response correlated positively with the level of cognitive function (BACS composite scores) in the right DLPFC, bilateral VLPFC, right FPC, and bilateral temporal regions in schizophrenia. The correlation was driven by all BACS domains. Our results suggest that the linked functional deficits in the right DLPFC, bilateral VLPFC, right FPC, and bilateral temporal regions may be related to BACS-measured cognitive impairments in schizophrenia and show that linking the neurocognitive deficits and brain abnormalities can increase our understanding of schizophrenia pathophysiology. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Establishing the functional connectivity of the frontotemporal network in pre-attentive change detection with Transcranial Magnetic Stimulation and event-related optical signal.

    PubMed

    Tse, Chun-Yu; Long-Yin, Yip; Lui, Troby Ka-Yan; Xiao, Xue-Zhen; Wang, Yang; Chu, Winnie Chiu Wing; Parks, Nathan Allen; Chan, Sandra Sau-Man; Neggers, Sebastiaan Franciscus Wijnandus

    2018-06-18

    Current theories of pre-attentive deviant detection postulate that before the Superior Temporal Cortex (STC) detects a change, the Inferior Frontal Cortex (IFC) engages in stimulus analysis, which is particularly critical for ambiguous deviations (e.g., deviant preceded by a short train of standards). These theories rest on the assumption that IFC and STC are functionally connected, which has only been supported by correlational brain imaging studies. We examined this functional connectivity assumption by applying Transcranial Magnetic Stimulation (TMS) to disrupt IFC function, while measuring the later STC mismatch response with the event-related optical signal (EROS). EROS can localize brain activity in both spatial and temporal dimensions via measurement of optical property changes associated with neuronal activity, and is inert to the electromagnetic interference produced by TMS. Specifically, the STC mismatch response at 120-180 ms elicited by a deviant preceded by a short standard train when IFC TMS was applied at 80 ms was compared with the STC mismatch responses in temporal control (TMS with 200 ms delay), spatial control (sham TMS at vertex), auditory control (TMS pulse noise only), and cognitive control (deviant preceded by a long standard train) conditions. The STC mismatch response to deviants preceded by the short train was abolished by TMS of the IFC at 80 ms, while the STC responses remained intact in all other control conditions. These results confirm the involvement of the IFC in the STC mismatch response and support a functional connection between IFC and STC. Copyright © 2018. Published by Elsevier Inc.

  2. Measuring pregnancy planning: An assessment of the London Measure of Unplanned Pregnancy among urban, south Indian women

    PubMed Central

    Rocca, Corinne H.; Krishnan, Suneeta; Barrett, Geraldine; Wilson, Mark

    2010-01-01

    We evaluated the psychometric properties of the London Measure of Unplanned Pregnancy among Indian women using classical methods and Item Response Modeling. The scale exhibited good internal consistency and internal structure, with overall scores correlating well with each item’s response categories. Items performed similarly for pregnant and non-pregnant women, and scores decreased with increasing parity, providing evidence for validity. Analyses also detected limitations, including infrequent selection of middle response categories and some evidence of differential item functioning by parity. We conclude that the LMUP represents an improvement over existing measures but recommend steps for enhancing scale performance for this cultural context. PMID:21170147

  3. Dissociating interference-control processes between memory and response.

    PubMed

    Bissett, Patrick G; Nee, Derek Evan; Jonides, John

    2009-09-01

    The ability to mitigate interference is of central importance to cognition. Previous research has provided conflicting accounts about whether operations that resolve interference are singular in character or form a family of functions. Here, the authors examined the relationship between interference-resolution processes acting on working memory representations versus responses. The authors combined multiple forms of interference into a single paradigm by merging a directed-forgetting task, which induces proactive interference, with a stop-signal task, which taps response inhibition processes. The results demonstrated that proactive interference and response inhibition produced distinct behavioral signatures that did not interact. By contrast, combining two different measures of response inhibition by merging a go/no-go task variant and a stop signal produced overadditive behavioral interference, demonstrating that different forms of response inhibition tap the same processes. However, not all forms of response conflict interacted, suggesting that inhibition-related functions acting on response selection are dissociable from those acting on response inhibition. These results suggest that inhibition-related functions for memory and responses are dissociable. (c) 2009 APA, all rights reserved.

  4. The Response Shift Bias in Self-Report Tests: A Function of an Expectation of Change or a Shift in Internal Scaling?

    ERIC Educational Resources Information Center

    Riedel, Sharon; And Others

    Self-report, pre/post testing is a frequently employed measure of therapeutic change. To investigate whether expectation of change might be an alternative explanation to the scale shift explanation of response shift bias in a self-report measure, a two-session assertiveness training intervention for college women was evaluated under manipulated…

  5. Adversity-driven changes in hypothalamic-pituitary-adrenal axis functioning during adolescence. The trails study.

    PubMed

    Laceulle, Odilia M; Nederhof, Esther; van Aken, Marcel A G; Ormel, Johan

    2017-11-01

    The hypothalamic-pituitary-adrenal (HPA) axis has been proposed to be a key mechanism underlying the link between adversity and mental health, but longitudinal studies on adversity and HPA-axis functioning are scarce. Here, we studied adversity-driven changes in HPA-axis functioning during adolescence (N=141). HPA-axis functioning (basal cortisol, cortisol awakening response, anticipation of, reaction to and recovery after a stress task) was measured twice, at age 16 and 19. Adversity (i.e., social defeat and loss/illness) since age 16 was measured extensively with the Life Stress Interview at age 19. Adolescents who reported being exposed to social defeat showed increases in basal cortisol (ɳ 2 =0.029) and decreases in reaction to the stress task (ɳ 2 =0.030) from age 16-19, compared to their peers in the loss/illness and no stress group. The current study provides unique longitudinal data on the role of adversity in HPA-axis functioning. Evidence is provided that adversity can affect the body's neuroendocrine response to stress, dependent on the nature of both the HPA-measures and adverse events under study. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Rasch validation of the Arabic version of the lower extremity functional scale.

    PubMed

    Alnahdi, Ali H

    2018-02-01

    The purpose of this study was to examine the internal construct validity of the Arabic version of the Lower Extremity Functional Scale (20-item Arabic LEFS) using Rasch analysis. Patients (n = 170) with lower extremity musculoskeletal dysfunction were recruited. Rasch analysis of 20-item Arabic LEFS was performed. Once the initial Rasch analysis indicated that the 20-item Arabic LEFS did not fit the Rasch model, follow-up analyses were conducted to improve the fit of the scale to the Rasch measurement model. These modifications included removing misfitting individuals, changing item scoring structure, removing misfitting items, addressing bias caused by response dependency between items and differential item functioning (DIF). Initial analysis indicated deviation of the 20-item Arabic LEFS from the Rasch model. Disordered thresholds in eight items and response dependency between six items were detected with the scale as a whole did not meet the requirement of unidimensionality. Refinements led to a 15-item Arabic LEFS that demonstrated excellent internal consistency (person separation index [PSI] = 0.92) and satisfied all the requirement of the Rasch model. Rasch analysis did not support the 20-item Arabic LEFS as a unidimensional measure of lower extremity function. The refined 15-item Arabic LEFS met all the requirement of the Rasch model and hence is a valid objective measure of lower extremity function. The Rasch-validated 15-item Arabic LEFS needs to be further tested in an independent sample to confirm its fit to the Rasch measurement model. Implications for Rehabilitation The validity of the 20-item Arabic Lower Extremity Functional Scale to measure lower extremity function is not supported. The 15-item Arabic version of the LEFS is a valid measure of lower extremity function and can be used to quantify lower extremity function in patients with lower extremity musculoskeletal disorders.

  7. Comparing individual differences in inconsistency and plasticity as predictors of cognitive function in older adults.

    PubMed

    Grand, Jacob H G; Stawski, Robert S; MacDonald, Stuart W S

    2016-01-01

    Recent theorizing differentiates key constraints on cognition, including one's current range of processing efficiency (i.e., flexibility or inconsistency) as well as the capacity to expand flexibility over time (i.e., plasticity). The present study uses intensive assessment of response time data to examine the interplay between markers of intraindividual variability (inconsistency) and gains across biweekly retest sessions (plasticity) in relation to age-related cognitive function. Participants included 304 adults (aged 64 to 92 years: M = 74.02, SD = 5.95) from Project MIND, a longitudinal burst design study assessing performance across micro and macro intervals (response latency trials, weekly bursts, annual retests). For two reaction time (RT) measures (choice RT and one-back choice RT), baseline measures of RT inconsistency (intraindividual standard deviation, ISD, across trials at the first testing session) and plasticity (within-person performance gains in average RT across the 5 biweekly burst sessions) were computed and were then employed in linear mixed models as predictors of individual differences in cognitive function and longitudinal (6-year) rates of cognitive change. Independent of chronological age and years of education, higher RT inconsistency was associated uniformly with poorer cognitive function at baseline and with increased cognitive decline for measures of episodic memory and crystallized verbal ability. In contrast, predictive associations for plasticity were more modest for baseline cognitive function and were absent for 6-year cognitive change. These findings underscore the potential utility of response times for articulating inconsistency and plasticity as dynamic predictors of cognitive function in older adults.

  8. Blind source separation in retinal videos

    NASA Astrophysics Data System (ADS)

    Barriga, Eduardo S.; Truitt, Paul W.; Pattichis, Marios S.; Tüso, Dan; Kwon, Young H.; Kardon, Randy H.; Soliz, Peter

    2003-05-01

    An optical imaging device of retina function (OID-RF) has been developed to measure changes in blood oxygen saturation due to neural activity resulting from visual stimulation of the photoreceptors in the human retina. The video data that are collected represent a mixture of the functional signal in response to the retinal activation and other signals from undetermined physiological activity. Measured changes in reflectance in response to the visual stimulus are on the order of 0.1% to 1.0% of the total reflected intensity level which makes the functional signal difficult to detect by standard methods since it is masked by the other signals that are present. In this paper, we apply principal component analysis (PCA), blind source separation (BSS), using Extended Spatial Decorrelation (ESD) and independent component analysis (ICA) using the Fast-ICA algorithm to extract the functional signal from the retinal videos. The results revealed that the functional signal in a stimulated retina can be detected through the application of some of these techniques.

  9. Objective visual assessment of antiangiogenic treatment for wet age-related macular degeneration.

    PubMed

    Baseler, Heidi A; Gouws, André; Crossland, Michael D; Leung, Carmen; Tufail, Adnan; Rubin, Gary S; Morland, Antony B

    2011-10-01

    To assess cortical responses in patients undergoing antiangiogenic treatment for wet age-related macular degeneration (AMD) using functional magnetic resonance imaging (fMRI) as an objective, fixation-independent measure of topographic visual function. A patient with bilateral neovascular AMD was scanned using fMRI before and at regular intervals while undergoing treatment with intravitreal antiangiogenic injections (ranibizumab). Blood oxygenation level-dependent signals were measured in the brain while the patient viewed a stimulus consisting of a full-field flickering (6 Hz) white light alternating with a uniform gray background (18 s on and 18 s off). Topographic distribution and magnitude of activation in visual cortex were compared longitudinally throughout the treatment period (<1 year) and with control patients not currently undergoing treatment. Clinical behavioral tests were also administered, including visual acuity, microperimetry, and reading skills. The area of visual cortex activated increased significantly after the first treatment to include more posterior cortex that normally receives inputs from lesioned parts of the retina. Subsequent treatments yielded no significant further increase in activation area. Behavioral measures all generally showed an improvement with treatment but did not always parallel one another. The untreated control patient showed a consistent lack of significant response in the cortex representing retinal lesions. Retinal treatments may not only improve vision but also result in a concomitant improvement in fixation stability. Current clinical behavioral measures (e.g., acuity and perimetry) are largely dependent on fixation stability and therefore cannot separate improvements of visual function from fixation improvements. fMRI, which provides an objective and sensitive measure of visual function independent of fixation, reveals a significant increase in visual cortical responses in patients with wet AMD after treatment with antiangiogenic injections. Despite recent evidence that visual cortex degenerates subsequent to retinal lesions, our results indicate that it can remain responsive as its inputs are restored.

  10. Clinical relevance of gait research applied to clinical trials in spinal cord injury.

    PubMed

    Ditunno, John; Scivoletto, Giorgio

    2009-01-15

    The restoration of walking function following SCI is extremely important to consumers and has stimulated a response of new treatments by scientists, the pharmaceutical industry and clinical entrepreneurs. Several of the proposed interventions: (1) the use of functional electrical stimulation (FES) and (2) locomotor training have been examined in clinical trials and recent reviews of the scientific literature. Each of these interventions is based on research of human locomotion. Therefore, the systematic study of walking function and gait in normal individuals and those with injury to the spinal cord has contributed to the identification of the impairments of walking, the development of new treatments and how they will be measured to determine effectiveness. In this context gait research applied to interventions to improve walking function is of high clinical relevance. This research helps identify walking impairments to be corrected and measures of walking function to be utilized as endpoints for clinical trials. The most common impairments following SCI diagnosed by observational gait analysis include inadequate hip extension during stance, persistent plantar flexion and hip/knee flexion during swing and foot placement at heel strike. FES has been employed as one strategy for correcting these impairments based on analysis that range from simple measures of speed, cadence and stride length to more sophisticated systems of three- dimensional video motion analysis and multichannel EMG tracings of integrated walking. A recent review of the entire FES literature identified 36 studies that merit comment and the full range of outcome measures for walking function were used from simple velocity to the video analysis of motion. In addition to measures of walking function developed for FES interventions, the first randomized multicenter clinical trial on locomotor training in subacute SCI was recently published with an extensive review of these measures. In this study outcome measures of motor strength (impairment), balance, Walking Index for SCI (WISCI), speed, 5min walk (walking capacities) and locomotor functional independence measure (L-FIM), a disability measure all showed improvement in walking function based on the strategy of the response of activity based plasticity to step training. Although the scientific basis for this intervention will be covered in other articles in this series, the evolution of clinical outcome measures of walking function continues to be important for the determination of effectiveness in clinical trials.

  11. Linking runoff response to burn severity after a wildfire

    USGS Publications Warehouse

    Moody, J.A.; Martin, D.A.; Haire, S.L.; Kinner, D.A.

    2008-01-01

    Extreme floods often follow wildfire in mountainous watersheds. However, a quantitative relation between the runoff response and burn severity at the watershed scale has not been established. Runoff response was measured as the runoff coefficient C, which is equal to the peak discharge per unit drainage area divided by the average maximum 30 min rainfall intensity during each rain storm. The magnitude of the bum severity was expressed as the change in the normalized burn ratio. A new burn severity variable, hydraulic functional connectivity ?? was developed and incorporates both the magnitude of the burn severity and the spatial sequence of the bum severity along hillslope flow paths. The runoff response and the burn severity were measured in seven subwatersheds (0.24 to 0.85 km2) in the upper part of Rendija Canyon burned by the 2000 Cerro Grande Fire Dear Los Alamos, New Mexico, USA. A rainfall-discharge relation was determined for four of the subwatersheds with nearly the same bum severity. The peak discharge per unit drainage area Qupeak was a linear function of the maximum 30 min rainfall intensity I30. This function predicted a rainfall intensity threshold of 8.5 mm h-1 below which no runoff was generated. The runoff coefficient C = Qupeak/I30 was a linear function of the mean hydraulic functional connectivity of the subwatersheds. Moreover, the variability of the mean hydraulic functional connectivity was related to the variability of the mean runoff coefficient, and this relation provides physical insight into why the runoff response from the same subwatershed can vary for different rainstorms with the same rainfall intensity. Published in 2007 by John Wiley & Sons, Ltd.

  12. Assessment of platelet function in healthy cats in response to commonly prescribed antiplatelet drugs using three point-of-care platelet function tests.

    PubMed

    Ho, Kimberly K; Abrams-Ogg, Anthony Cg; Wood, R Darren; O'Sullivan, M Lynne; Kirby, Gordon M; Blois, Shauna L

    2017-06-01

    Objectives The objective was to determine if decreased platelet function could be detected after treatment with aspirin and/or clopidogrel in healthy cats using three point-of-care platelet function tests that evaluate platelet function by different methods: Multiplate (by impedance), Platelet Function Analyzer 100 (by mechanical aperture closure) and Plateletworks (by platelet counting). Methods Thirty-six healthy cats were randomly assigned to receive one of three oral treatments over an 8 day period: (1) aspirin 5 mg q72h; (2) aspirin 20.25 mg q72h; or (3) clopidogrel 18.75 mg q24h. Cats treated with 5 and 20.25 mg aspirin also received clopidogrel on days 4-8. Platelet aggregation in response to adenosine diphosphate and collagen ± arachidonic acid was assessed on days 1 (baseline), 4 and 8. Aspirin and clopidogrel metabolites were measured by high-performance liquid chromatography. Platelet function in response to treatment was analyzed by ANCOVA, linear regression and Spearman correlation. Results The only solitary aspirin effect was detected using Plateletworks with collagen in cats treated with 20.25 mg. The only effect detected by Multiplate was using arachidonic acid in cats treated with both aspirin 20.25 mg and clopidogrel. All clopidogrel treatment effects were detected by Platelet Function Analyzer 100, Plateletworks (adenosine diphosphate) and Plateletworks (collagen). Drug metabolites were present in all cats, but concentrations were minimally correlated to platelet function test results. Conclusions and relevance Platelet Function Analyzer 100 and Plateletworks using adenosine diphosphate ± collagen agonists may be used to detect decreased platelet function in response to clopidogrel treatment. Either aspirin is not as effective an antiplatelet drug as clopidogrel, or the tests used were not optimal to measure aspirin effect. Cats with heart disease are commonly prescribed antiplatelet drugs to decrease the risk of aortic thromboembolism. Platelet Function Analyzer 100 and Plateletworks may be useful for confirming clopidogrel treatment in these cats.

  13. Multivariate functional response regression, with application to fluorescence spectroscopy in a cervical pre-cancer study.

    PubMed

    Zhu, Hongxiao; Morris, Jeffrey S; Wei, Fengrong; Cox, Dennis D

    2017-07-01

    Many scientific studies measure different types of high-dimensional signals or images from the same subject, producing multivariate functional data. These functional measurements carry different types of information about the scientific process, and a joint analysis that integrates information across them may provide new insights into the underlying mechanism for the phenomenon under study. Motivated by fluorescence spectroscopy data in a cervical pre-cancer study, a multivariate functional response regression model is proposed, which treats multivariate functional observations as responses and a common set of covariates as predictors. This novel modeling framework simultaneously accounts for correlations between functional variables and potential multi-level structures in data that are induced by experimental design. The model is fitted by performing a two-stage linear transformation-a basis expansion to each functional variable followed by principal component analysis for the concatenated basis coefficients. This transformation effectively reduces the intra-and inter-function correlations and facilitates fast and convenient calculation. A fully Bayesian approach is adopted to sample the model parameters in the transformed space, and posterior inference is performed after inverse-transforming the regression coefficients back to the original data domain. The proposed approach produces functional tests that flag local regions on the functional effects, while controlling the overall experiment-wise error rate or false discovery rate. It also enables functional discriminant analysis through posterior predictive calculation. Analysis of the fluorescence spectroscopy data reveals local regions with differential expressions across the pre-cancer and normal samples. These regions may serve as biomarkers for prognosis and disease assessment.

  14. Opiates and cerebral functional activity in rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trusk, T.C.

    1986-01-01

    Cerebral activity was measured using the free-fatty acid (1-/sup 14/C) octanoate as a fast functional tracer in conscious, unrestrained rats 5 minutes after intravenous injection of heroin, cocaine or saline vehicle. Regional changes of octanoate labeling density in the autoradiograms relative to saline-injected animals were used to determine the functional activity effects of each drug. Heroin and cocaine each produced a distinctive pattern of activity increases and suppression throughout the rat brain. Similar regional changes induced by both drugs were found in limbic brain regions implicated in drug reinforcement. Labeled octanoate autoradiography was used to measure the cerebral functional responsemore » to a tone that had previously been paired to heroin injections. Rats were trained in groups of three consisting of one heroin self-administration animal, and two animals receiving yoked infusion of heroin or saline. A tone was paired with each infusion during training. Behavioral experiments in similarly trained rats demonstrated that these training conditions impart secondary reinforcing properties to the tone in animals previously self-administering heroin, while the tone remains behaviorally neutral in yoked-infusion rats. Cerebral functional activity was measured during presentation of the tone without drug infusion. Octanoate labeling density changed in fifteen brain areas in response to the tone previously paired to heroin without response contingency. Labeling density was significantly modified in sixteen regions as a result of previously pairing the tone to response-contingent heroin infusions.« less

  15. The Longitudinal Impact of Parent Distress and Behavior on Functional Outcomes Among Youth With Chronic Pain.

    PubMed

    Chow, Erika T; Otis, John D; Simons, Laura E

    2016-06-01

    Accumulating evidence supports the concurrent association between parent distress and behavior and child functioning in the context of chronic pain, with existing longitudinal studies limited to a pediatric surgical context that identify parent catastrophizing as influential. In this study, we examined how parent factors assessed at a multidisciplinary pediatric pain clinic evaluation affect child psychological and functional outcomes over time. A cohort of 195 patients with chronic pain (ages 8-17 years) and their parents who presented for a multidisciplinary evaluation completed measures at baseline and at 4-month follow-up. Patients completed measures of pain catastrophizing, pain-related fear and avoidance, generalized anxiety, depressive symptoms, and functional disability. Parents completed measures of pain catastrophizing, pain-related fear and avoidance, and protective responses to child pain. Parent-reported child school functioning was also collected. Parent distress and behavior was concurrently associated with child distress and functioning at evaluation. After controlling for baseline child functioning, baseline parent avoidance and protective behavior emerged as significant predictors of child functioning at 4-month follow-up. Parent distress and behavior influence child distress and functioning over time and these findings identify key parent domains to target in the context of a child's pain treatment. Parent behavior, specifically avoidance and protective responses, influence child distress and functioning over time. Child pain treatment interventions should include influential parent factors to ensure successful outcomes. Copyright © 2016 American Pain Society. Published by Elsevier Inc. All rights reserved.

  16. Responsibility modulates pain-matrix activation elicited by the expressions of others in pain

    PubMed Central

    Cui, Fang; Abdelgabar, Abdel-Rahman; Keysers, Christian; Gazzola, Valeria

    2015-01-01

    Here we examine whether brain responses to dynamic facial expressions of pain are influenced by our responsibility for the observed pain. Participants played a flanker task with a confederate. Whenever either erred, the confederate was seen to receive a noxious shock. Using functional magnetic resonance imaging, we found that regions of the functionally localized pain-matrix of the participants (the anterior insula in particular) were activated most strongly when seeing the confederate receive a noxious shock when only the participant had erred (and hence had full responsibility). When both or only the confederate had erred (i.e. participant's shared or no responsibility), significantly weaker vicarious pain-matrix activations were measured. PMID:25800210

  17. The non-equilibrium response of a superconductor to pair-breaking radiation measured over a broad frequency band

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Visser, P. J. de, E-mail: p.j.devisser@tudelft.nl; Yates, S. J. C.; Guruswamy, T.

    2015-06-22

    We have measured the absorption of terahertz radiation in a BCS superconductor over a broad range of frequencies from 200 GHz to 1.1 THz, using a broadband antenna-lens system and a tantalum microwave resonator. From low frequencies, the response of the resonator rises rapidly to a maximum at the gap edge of the superconductor. From there on, the response drops to half the maximum response at twice the pair-breaking energy. At higher frequencies, the response rises again due to trapping of pair-breaking phonons in the superconductor. In practice, this is a measurement of the frequency dependence of the quasiparticle creationmore » efficiency due to pair-breaking in a superconductor. The efficiency, calculated from the different non-equilibrium quasiparticle distribution functions at each frequency, is in agreement with the measurements.« less

  18. Effects of Chronic Environmental Cold on Growth, Health and Select Metabolic and Immunologic Responses of Preruminant Calves

    USDA-ARS?s Scientific Manuscript database

    The physiological response of the preruminant calf to sustained exposure to cold has not been studied extensively. Effects of cold on growth performance and health of preruminant calves as well as functional measures of energy metabolism, fat-soluble vitamin, and immune responsiveness were evaluate...

  19. A Cross-Validation Approach to Approximate Basis Function Selection of the Stall Flutter Response of a Rectangular Wing in a Wind Tunnel

    NASA Technical Reports Server (NTRS)

    Kukreja, Sunil L.; Vio, Gareth A.; Andrianne, Thomas; azak, Norizham Abudl; Dimitriadis, Grigorios

    2012-01-01

    The stall flutter response of a rectangular wing in a low speed wind tunnel is modelled using a nonlinear difference equation description. Static and dynamic tests are used to select a suitable model structure and basis function. Bifurcation criteria such as the Hopf condition and vibration amplitude variation with airspeed were used to ensure the model was representative of experimentally measured stall flutter phenomena. Dynamic test data were used to estimate model parameters and estimate an approximate basis function.

  20. The influence of unilateral saccular impairment on functional balance performance and self-report dizziness.

    PubMed

    McCaslin, Devin L; Jacobson, Gary P; Grantham, Sarah L; Piker, Erin G; Verghese, Susha

    2011-09-01

    Postural stability in humans is largely maintained by vestibular, visual, and somatosensory inputs to the central nervous system. Recent clinical advances in the assessment of otolith function (e.g., cervical and ocular vestibular evoked myogenic potentials [cVEMPs and oVEMPs], subjective visual vertical [SVV] during eccentric rotation) have enabled investigators to identify patients with unilateral otolith impairments. This research has suggested that patients with unilateral otolith impairments perform worse than normal healthy controls on measures of postural stability. It is not yet known if patients with unilateral impairments of the saccule and/or inferior vestibular nerve (i.e., unilaterally abnormal cVEMP) perform differently on measures of postural stability than patients with unilateral impairments of the horizontal SCC (semicircular canal) and/or superior vestibular nerve (i.e., unilateral caloric weakness). Further, it is not known what relationship exists, if any, between otolith system impairment and self-report dizziness handicap. The purpose of this investigation was to determine the extent to which saccular impairments (defined by a unilaterally absent cVEMP) and impairments of the horizontal semicircular canal (as measured by the results of caloric testing) affect vestibulospinal function as measured through the Sensory Organization Test (SOT) of the computerized dynamic posturography (CDP). A secondary objective of this investigation was to measure the effects, if any, that saccular impairment has on a modality-specific measure of health-related quality of life. A retrospective cohort study. Subjects were assigned to one of four groups based on results from balance function testing: Group 1 (abnormal cVEMP response only), Group 2 (abnormal caloric response only), Group 3 (abnormal cVEMP and abnormal caloric response), and Group 4 (normal control group). Subjects were 92 adult patients: 62 were seen for balance function testing due to complaints of dizziness, vertigo, or unsteadiness, and 30 served as controls. All subjects underwent videonystagmography or electronystagmography (VNG/ENG), vestibular evoked myogenic potentials (VEMPs), self-report measures of self-perceived dizziness disability/handicap (Dizziness Handicap Inventory), and tests of postural control (Neurocom Equitest). Subjects were categorized into one of four groups based on balance function test results. All variables were subjected to a multifactor analysis of variance (ANOVA). The Dizziness Handicap Inventory (DHI) total scores and equilibrium scores served as the dependent variables. Results showed that patients with abnormal unilateral saccular or inferior vestibular nerve function (i.e., abnormal cVEMP) demonstrated significantly impaired postural control when compared to normal participants. However, this group demonstrated significantly better postural stability when compared to the group with abnormal caloric responses alone and the group with abnormal caloric responses and abnormal cVEMP results. Patients with an abnormal cVEMP did not differ significantly on the DHI compared to the other two impaired groups. We interpret these findings as evidence that a significantly asymmetrical cVEMP in isolation negatively impacts performance on measures of postural control compared to normal subjects but not compared to patients with significant caloric weaknesses. However, patients with a unilaterally abnormal cVEMP do not differ from patients with significant caloric weaknesses in regard to self-perceived dizziness handicap. American Academy of Audiology.

  1. Response functions for neutron skyshine analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gui, A.A.; Shultis, J.K.; Faw, R.E.

    1997-02-01

    Neutron and associated secondary photon line-beam response functions (LBRFs) for point monodirectional neutron sources are generated using the MCNP Monte Carlo code for use in neutron skyshine analysis employing the integral line-beam method. The LBRFs are evaluated at 14 neutron source energies ranging from 0.01 to 14 MeV and at 18 emission angles from 1 to 170 deg, as measured from the source-to-detector axis. The neutron and associated secondary photon conical-beam response functions (CBRFs) for azimuthally symmetric neutron sources are also evaluated at 13 neutron source energies in the same energy range and at 13 polar angles of source collimationmore » from 1 to 89 deg. The response functions are approximated by an empirical three-parameter function of the source-to-detector distance. These response function approximations are available for a source-to-detector distance up to 2,500 m and, for the first time, give dose equivalent responses that are required for modern radiological assessments. For the CBRFs, ground correction factors for neutrons and secondary photons are calculated and also approximated by empirical formulas for use in air-over-ground neutron skyshine problems with azimuthal symmetry. In addition, simple procedures are proposed for humidity and atmospheric density corrections.« less

  2. Functional connectivity in the prefrontal cortex measured by near-infrared spectroscopy during ultrarapid object recognition

    NASA Astrophysics Data System (ADS)

    Medvedev, Andrei V.; Kainerstorfer, Jana M.; Borisov, Sergey V.; Vanmeter, John

    2011-01-01

    Near-infrared spectroscopy (NIRS) is a developing technology for low-cost noninvasive functional brain imaging. With multichannel optical instruments, it becomes possible to measure not only local changes in hemoglobin concentrations but also temporal correlations of those changes in different brain regions which gives an optical analog of functional connectivity traditionally measured by fMRI. We recorded hemodynamic activity during the Go-NoGo task from 11 right-handed subjects with probes placed bilaterally over prefrontal areas. Subjects were detecting animals as targets in natural scenes pressing a mouse button. Data were low-pass filtered <1 Hz and cardiac/respiration/superficial layers artifacts were removed using Independent Component Analysis. Fisher's transformed correlations of poststimulus responses (30 s) were averaged over groups of channels unilaterally in each hemisphere (intrahemispheric connectivity) and the corresponding channels between hemispheres (interhemispheric connectivity). The hemodynamic response showed task-related activation (an increase/decrease in oxygenated/deoxygenated hemoglobin, respectively) greater in the right versus left hemisphere. Intra- and interhemispheric functional connectivity was also significantly stronger during the task compared to baseline. Functional connectivity between the inferior and the middle frontal regions was significantly stronger in the right hemisphere. Our results demonstrate that optical methods can be used to detect transient changes in functional connectivity during rapid cognitive processes.

  3. Yoga practice improves executive function by attenuating stress levels.

    PubMed

    Gothe, Neha P; Keswani, Rahul K; McAuley, Edward

    2016-12-01

    Prolonged activation of the hypothalamus-pituitary-adrenal system is thought to have deleterious effects on brain function. Neuroendocrine studies suggest that brain exposure to higher cortisol concentrations contribute to cognitive deficits as we age. Mind-body techniques such as yoga have shown to improve stress levels by restoring the body's sympathetic-parasympathetic balance. The objective of this study was to determine whether yoga practice moderated the stress response resulting in improved executive function. Sedentary community dwelling older adults (N=118, Mean age=62.02) were randomized to an 8-week yoga intervention or a stretching control group. At baseline and following 8 weeks, all participants completed measures of executive function, self-reported stress and anxiety and provided saliva samples before and after cognitive testing to assess cortisol. Yoga participants showed improved accuracy on executive function measures and an attenuated cortisol response compared to their stretching counterparts who showed increased cortisol levels and poor cognitive performance at follow up. The change in cortisol levels as well as self-reported stress and anxiety levels predicted performance on the running span task, n-back working memory and task switching paradigm (β's=0.27-0.38, p's≤0.05 for yoga and β's=-0.37-0.47, p's≤0.01 for stretching control). Eight weeks of regular yoga practice resulted in improved working memory performance that was mediated by an attenuated response to stress as measured by self-report stress and objective salivary cortisol measurements. This trial offers evidence for non-traditional physical activity interventions such as yoga that may be helpful in restoring HPA balance in older adults, thereby preventing cognitive decline. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. The accuracy of assessment of walking distance in the elective spinal outpatients setting.

    PubMed

    Okoro, Tosan; Qureshi, Assad; Sell, Beulah; Sell, Philip

    2010-02-01

    Self reported walking distance is a clinically relevant measure of function. The aim of this study was to define patient accuracy and understand factors that might influence perceived walking distance in an elective spinal outpatients setting. A prospective cohort study. 103 patients were asked to perform one test of distance estimation and 2 tests of functional distance perception using pre-measured landmarks. Standard spine specific outcomes included the patient reported claudication distance, Oswestry disability index (ODI), Low Back Outcome Score (LBOS), visual analogue score (VAS) for leg and back, and other measures. There are over-estimators and under-estimators. Overall, the accuracy to within 9.14 metres (m) (10 yards) was poor at only 5% for distance estimation and 40% for the two tests of functional distance perception. Distance: Actual distance 111 m; mean response 245 m (95% CI 176.3-314.7), Functional test 1 actual distance 29.2 m; mean response 71.7 m (95% CI 53.6-88.9) Functional test 2 actual distance 19.6 m; mean response 47.4 m (95% CI 35.02-59.95). Surprisingly patients over 60 years of age (n = 43) are twice as accurate with each test performed compared to those under 60 (n = 60) (average 70% overestimation compared to 140%; p = 0.06). Patients in social class I (n = 18) were more accurate than those in classes II-V (n = 85): There was a positive correlation between poor accuracy and increasing MZD (Pearson's correlation coefficient 0.250; p = 0.012). ODI, LBOS and other parameters measured showed no correlation. Subjective distance perception and estimation is poor in this population. Patients over 60 and those with a professional background are more accurate but still poor.

  5. Frequency response of electrochemical cells

    NASA Technical Reports Server (NTRS)

    Thomas, Daniel L.

    1989-01-01

    Impedance concepts can be applied to the analysis of battery electrodes, yielding information about the structure of the electrode and the processes occurring in the electrode. Structural parameters such as the specific area (surface area per gram of electrode) can be estimated. Electrode variables such as surface overpotential, ohmic losses, and diffusion limitations may be studied. Nickel and cadmium electrodes were studied by measuring the ac impedance as a function of frequency, and the specific areas that were determined were well within the range of specific areas determined from BET measurements. Impedance spectra were measured for the nickel and cadmium electrodes, and for a 20 A-hr NiCd battery as functions of the state of charge. More work is needed to determine the feasibility of using frequency response as a nondestructive testing technique for batteries.

  6. Development and initial validation of a brief self-report measure of cognitive dysfunction in fibromyalgia.

    PubMed

    Kratz, Anna L; Schilling, Stephen G; Goesling, Jenna; Williams, David A

    2015-06-01

    Pain is often the focus of research and clinical care in fibromyalgia (FM); however, cognitive dysfunction is also a common, distressing, and disabling symptom in FM. Current efforts to address this problem are limited by the lack of a comprehensive, valid measure of subjective cognitive dysfunction in FM that is easily interpretable, accessible, and brief. The purpose of this study was to leverage cognitive functioning item banks that were developed as part of the Patient Reported Outcomes Measurement Information System (PROMIS) to devise a 10-item short form measure of cognitive functioning for use in FM. In study 1, a nationwide (U.S.) sample of 1,035 adults with FM (age range = 18-82, 95.2% female) completed 2 cognitive item pools. Factor analyses and item response theory analyses were used to identify dimensionality and optimally performing items. A recommended 10-item measure, called the Multidimensional Inventory of Subjective Cognitive Impairment (MISCI) was created. In study 2, 232 adults with FM completed the MISCI and a legacy measure of cognitive functioning that is used in FM clinical trials, the Multiple Ability Self-Report Questionnaire (MASQ). The MISCI showed excellent internal reliability, low ceiling/floor effects, and good convergent validity with the MASQ (r = -.82). This paper presents the MISCI, a 10-item measure of cognitive dysfunction in FM, developed through classical test theory and item response theory. This brief but comprehensive measure shows evidence of excellent construct validity through large correlations with a lengthy legacy measure of cognitive functioning. Copyright © 2015 American Pain Society. Published by Elsevier Inc. All rights reserved.

  7. Food safety security: a new concept for enhancing food safety measures.

    PubMed

    Iyengar, Venkatesh; Elmadfa, Ibrahim

    2012-06-01

    The food safety security (FSS) concept is perceived as an early warning system for minimizing food safety (FS) breaches, and it functions in conjunction with existing FS measures. Essentially, the function of FS and FSS measures can be visualized in two parts: (i) the FS preventive measures as actions taken at the stem level, and (ii) the FSS interventions as actions taken at the root level, to enhance the impact of the implemented safety steps. In practice, along with FS, FSS also draws its support from (i) legislative directives and regulatory measures for enforcing verifiable, timely, and effective compliance; (ii) measurement systems in place for sustained quality assurance; and (iii) shared responsibility to ensure cohesion among all the stakeholders namely, policy makers, regulators, food producers, processors and distributors, and consumers. However, the functional framework of FSS differs from that of FS by way of: (i) retooling the vulnerable segments of the preventive features of existing FS measures; (ii) fine-tuning response systems to efficiently preempt the FS breaches; (iii) building a long-term nutrient and toxicant surveillance network based on validated measurement systems functioning in real time; (iv) focusing on crisp, clear, and correct communication that resonates among all the stakeholders; and (v) developing inter-disciplinary human resources to meet ever-increasing FS challenges. Important determinants of FSS include: (i) strengthening international dialogue for refining regulatory reforms and addressing emerging risks; (ii) developing innovative and strategic action points for intervention {in addition to Hazard Analysis and Critical Control Points (HACCP) procedures]; and (iii) introducing additional science-based tools such as metrology-based measurement systems.

  8. Performance, physiological, and oculometer evaluation of VTOL landing displays

    NASA Technical Reports Server (NTRS)

    North, R. A.; Stackhouse, S. P.; Graffunder, K.

    1979-01-01

    A methodological approach to measuring workload was investigated for evaluation of new concepts in VTOL aircraft displays. Physiological, visual response, and conventional flight performance measures were recorded for landing approaches performed in the NASA Visual Motion Simulator (VMS). Three displays (two computer graphic and a conventional flight director), three crosswind amplitudes, and two motion base conditions (fixed vs. moving base) were tested in a factorial design. Multivariate discriminant functions were formed from flight performance and/or visual response variables. The flight performance variable discriminant showed maximum differentation between crosswind conditions. The visual response measure discriminant maximized differences between fixed vs. motion base conditions and experimental displays. Physiological variables were used to attempt to predict the discriminant function values for each subject/condition trial. The weights of the physiological variables in these equations showed agreement with previous studies. High muscle tension, light but irregular breathing patterns, and higher heart rate with low amplitude all produced higher scores on this scale and thus represent higher workload levels.

  9. Item response theory analysis of the life orientation test-revised: age and gender differential item functioning analyses.

    PubMed

    Steca, Patrizia; Monzani, Dario; Greco, Andrea; Chiesi, Francesca; Primi, Caterina

    2015-06-01

    This study is aimed at testing the measurement properties of the Life Orientation Test-Revised (LOT-R) for the assessment of dispositional optimism by employing item response theory (IRT) analyses. The LOT-R was administered to a large sample of 2,862 Italian adults. First, confirmatory factor analyses demonstrated the theoretical conceptualization of the construct measured by the LOT-R as a single bipolar dimension. Subsequently, IRT analyses for polytomous, ordered response category data were applied to investigate the items' properties. The equivalence of the items across gender and age was assessed by analyzing differential item functioning. Discrimination and severity parameters indicated that all items were able to distinguish people with different levels of optimism and adequately covered the spectrum of the latent trait. Additionally, the LOT-R appears to be gender invariant and, with minor exceptions, age invariant. Results provided evidence that the LOT-R is a reliable and valid measure of dispositional optimism. © The Author(s) 2014.

  10. Evaluation of measurement equivalence of the Family Satisfaction with the End-of-Life Care in an ethnically diverse cohort: Tests of differential item functioning

    PubMed Central

    Teresi, Jeanne A; Ocepek-Welikson, Katja; Ramirez, Mildred; Kleinman, Marjorie; Ornstein, Katherine; Siu, Albert

    2016-01-01

    Background The Family Satisfaction with End-of-Life Care is an internationally used measure of satisfaction with cancer care. However, the Family Satisfaction with End-of-Life Care has not been studied for equivalence of item endorsement across different socio-demographic groups using differential item functioning. Aims The aims of this secondary data analysis were (1) to examine potential differential item functioning in the family satisfaction item set with respect to type of caregiver, race, and patient age, gender, and education and (2) to provide parameters and documentation of differential item functioning for an item bank. Design A mixed qualitative and quantitative analysis was conducted. A priori hypotheses regarding potential group differences in item response were established. Item response theory and Wald tests were used for the analyses of differential item functioning, accompanied by magnitude and impact measures. Results Very little significant differential item functioning was observed for patient's age and gender. For race, 13 items showed differential item functioning after multiple comparison adjustment, 10 with non-uniform differential item functioning. No items evidenced differential item functioning of high magnitude, and the impact was negligible. For education, 5 items evidenced uniform differential item functioning after adjustment, none of high magnitude. Differential item functioning impact was trivial. One item evidenced differential item functioning for the caregiver relationship variable. Conclusion Differential item functioning was observed primarily for race and education. No differential item functioning of high magnitude was observed for any item, and the overall impact of differential item functioning was negligible. One item, satisfaction with “the patient's pain relief,” might be singled out for further study, given that this item was both hypothesized and observed to show differential item functioning for race and education. PMID:25160692

  11. State of Modern Measurement Approaches in Social Work Research Literature

    ERIC Educational Resources Information Center

    Unick, George J.; Stone, Susan

    2010-01-01

    The need to develop measures that tap into constructs of interest to social work, refine existing measures, and ensure that measures function adequately across diverse populations of interest is critical. Item response theory (IRT) is a modern measurement approach that is increasingly seen as an essential tool in a number of allied professions.…

  12. Identifying ultrasensitive HGF dose-response functions in a 3D mammalian system for synthetic morphogenesis.

    PubMed

    Senthivel, Vivek Raj; Sturrock, Marc; Piedrafita, Gabriel; Isalan, Mark

    2016-12-16

    Nonlinear responses to signals are widespread natural phenomena that affect various cellular processes. Nonlinearity can be a desirable characteristic for engineering living organisms because it can lead to more switch-like responses, similar to those underlying the wiring in electronics. Steeper functions are described as ultrasensitive, and can be applied in synthetic biology by using various techniques including receptor decoys, multiple co-operative binding sites, and sequential positive feedbacks. Here, we explore the inherent non-linearity of a biological signaling system to identify functions that can potentially be exploited using cell genome engineering. For this, we performed genome-wide transcription profiling to identify genes with ultrasensitive response functions to Hepatocyte Growth Factor (HGF). We identified 3,527 genes that react to increasing concentrations of HGF, in Madin-Darby canine kidney (MDCK) cells, grown as cysts in 3D collagen cell culture. By fitting a generic Hill function to the dose-responses of these genes we obtained a measure of the ultrasensitivity of HGF-responsive genes, identifying a subset with higher apparent Hill coefficients (e.g. MMP1, TIMP1, SNORD75, SNORD86 and ERRFI1). The regulatory regions of these genes are potential candidates for future engineering of synthetic mammalian gene circuits requiring nonlinear responses to HGF signalling.

  13. Responses of susceptible subpopulations to nitrogen dioxide. Research report, June 1983-January 1988

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morrow, P.E.; Utell, M.J.

    1989-02-01

    Symptom responses and changes in pulmonary function were investigated in people with asthma or chronic obstructive pulmonary disease (COPD) exposed to 0.3 ppm nitrogen dioxide (NO{sub 2}) for four hours. Nonrespiratory-impaired (normal) subjects of comparable ages constituted the control groups. All exposures included periods of exercise and pulmonary function measurements. No significant symptomatic or physiological responses to NO{sub 2} could be detected in either the young or elderly control group. The asthmatic group did not manifest significant reductions in lung function after exposure to 0.3 ppm NO{sub 2}, compared to their preexposure baseline data or to their responses after amore » comparable four-hour exposure to air. During light exercise, subjects with COPD were progressively responsive to 0.3 ppm NO{sub 2}. Subgroup analyses within the asthmatic, COPD, and elderly normal subject groups and intergroup comparisons yielded significant findings and associations.« less

  14. Rasch measurement: the Arm Activity measure (ArmA) passive function sub-scale.

    PubMed

    Ashford, Stephen; Siegert, Richard J; Alexandrescu, Roxana

    2016-01-01

    To evaluate the conformity of the Arm Activity measure (ArmA) passive function sub-scale to the Rasch model. A consecutive cohort of patients (n = 92) undergoing rehabilitation, including upper limb rehabilitation and spasticity management, at two specialist rehabilitation units were included. Rasch analysis was used to examine scaling and conformity to the model. Responses were analysed using Rasch unidimensional measurement models (RUMM 2030). The following aspects were considered: overall model and individual item fit statistics and fit residuals, internal reliability, item response threshold ordering, item bias, local dependency and unidimensionality. ArmA contains both active and passive function sub-scales, but in this analysis only the passive function sub-scale was considered. Four of the seven items in the ArmA passive function sub-scale initially had disordered thresholds. These items were rescored to four response options, which resulted in ordered thresholds for all items. Once the items with disordered thresholds had been rescored, item bias was not identified for age, global disability level or diagnosis, but with a small difference in difficulty between males and females for one item of the scale. Local dependency was not observed and the unidimensionality of the sub-scale was supported and good fit to the Rasch model was identified. The person separation index (PSI) was 0.95 indicating that the scale is able to reliably differentiate at least two groups of patients. The ArmA passive function sub-scale was shown in this evaluation to conform to the Rasch model once disordered thresholds had been addressed. Using the logit scores produced by the Rasch model it was possible to convert this back to the original scale range. Implications for Rehabilitation The ArmA passive function sub-scale was shown, in this evaluation, to conform to the Rasch model once disordered thresholds had been addressed and therefore to be a clinically applicable and potentially useful hierarchical measure. Using Rasch logit scores it has be possible to convert back to the original ordinal scale range and provide an indication of real change to enable evaluation of clinical outcome of importance to patients and clinicians.

  15. Response of the oxygen uptake efficiency slope to orthotopic heart transplantation: lack of correlation with changes in central hemodynamic parameters and resting lung function.

    PubMed

    Van Laethem, Christophe; Goethals, Marc; Verstreken, Sofie; Walravens, Maarten; Wellens, Francis; De Proft, Margot; Bartunek, Jozef; Vanderheyden, Marc

    2007-09-01

    Recently, a new linear measure of ventilatory response to exercise, the oxygen uptake efficiency slope (OUES), was proposed in the evaluation of heart failure patients. No data are available on the response of the OUES after orthotopic heart transplantation (HTx). Thirty patients who underwent HTx between 1999 and 2003 were included in the study. Data from maximal cardiopulmonary exercise test, resting pulmonary function and hemodynamic assessment were collected before the transplant at time of screening and 1 year after HTx. During the first year after HTx, OUES and normalized OUES for body weight (OUES/kg) increased significantly from 15.6 +/- 4.9 to 19.7 +/- 4.8 (p < 0.05). Changes in OUES/kg were significantly correlated with changes in peak VO2, VAT and peak VE, and inversely to changes in peak VD/VT, but not to changes in VE/VCO2 slope (all p < 0.05). Changes in OUES or OUES/kg did not correlate with any changes in measures of resting lung volumes or capacities and measures of central hemodynamic function after HTx. OUES improved significantly after HTx, but, similar to other exercise parameters, remained considerably impaired. The changes in OUES were highly correlated with the improvements in other exercise variables, but did not correlate with marked improvements in central hemodynamics or resting lung function.

  16. Photosynthetic responses to temperature across leaf-canopy-ecosystem scales: a 15-year study in a Californian oak-grass savanna.

    PubMed

    Ma, Siyan; Osuna, Jessica L; Verfaillie, Joseph; Baldocchi, Dennis D

    2017-06-01

    Ecosystem CO 2 fluxes measured with eddy-covariance techniques provide a new opportunity to retest functional responses of photosynthesis to abiotic factors at the ecosystem level, but examining the effects of one factor (e.g., temperature) on photosynthesis remains a challenge as other factors may confound under circumstances of natural experiments. In this study, we developed a data mining framework to analyze a set of ecosystem CO 2 fluxes measured from three eddy-covariance towers, plus a suite of abiotic variables (e.g., temperature, solar radiation, air, and soil moisture) measured simultaneously, in a Californian oak-grass savanna from 2000 to 2015. Natural covariations of temperature and other factors caused remarkable confounding effects in two particular conditions: lower light intensity at lower temperatures and drier air and soil at higher temperatures. But such confounding effects may cancel out. At the ecosystem level, photosynthetic responses to temperature did follow a quadratic function on average. The optimum value of photosynthesis occurred within a narrow temperature range (i.e., optimum temperature, T opt ): 20.6 ± 0.6, 18.5 ± 0.7, 19.2 ± 0.5, and 19.0 ± 0.6 °C for the oak canopy, understory grassland, entire savanna, and open grassland, respectively. This paradigm confirms that photosynthesis response to ambient temperature changes is a functional relationship consistent across leaf-canopy-ecosystem scales. Nevertheless, T opt can shift with variations in light intensity, air dryness, or soil moisture. These findings will pave the way to a direct determination of thermal optima and limits of ecosystem photosynthesis, which can in turn provide a rich resource for baseline thresholds and dynamic response functions required for predicting global carbon balance and geographic shifts of vegetative communities in response to climate change.

  17. Differences in Perceived and Physiologic Genital Arousal Between Women With and Without Sexual Dysfunction.

    PubMed

    Handy, Ariel B; Stanton, Amelia M; Pulverman, Carey S; Meston, Cindy M

    2018-01-01

    Many sexual psychophysiologic studies have failed to find differences in physiologic genital arousal between women with and those without sexual dysfunction. However, differences in self-reported (ie, perceived) measures of genital responses between these 2 groups of women have been noted. To determine whether women with and without sexual dysfunction differ on measures of physiologic and perceived genital arousal based on type of analytic technique used, to explore differences in perceived genital arousal, and to assess the relation between physiologic and perceived genital arousal. Data from 5 studies (N = 214) were used in this analysis. Women were categorized into 3 groups: women with arousal-specific sexual dysfunction (n = 40), women with decreased sexual function (n = 72), and women who were sexually functional (n = 102). Women viewed an erotic film while their physiologic genital arousal was measured using a vaginal photoplethysmograph. After watching the film, women completed a self-report measure of perceived genital arousal. There were differences in vaginal pulse amplitude (VPA) levels and association of VPA with perceived genital sensations based on level of sexual function. Commonly used methods of analysis failed to identify significant differences in VPA among these groups of women. When VPA data were analyzed with hierarchical linear modeling, significant differences emerged. Notably, women with arousal-specific dysfunction exhibited lower VPA than sexually functional women at the beginning of the assessment. As the erotic film progressed, women with arousal-specific dysfunction became aroused at a faster rate than sexually functional women, and these 2 groups ultimately reached a similar level of VPA. Sexually functional women reported the highest levels of perceived genital responses among the 3 groups of women. No significant relation between VPA and perceived genital arousal emerged. Women's perception of their genital responses could play a role in women's experience of sexual dysfunction and might be more clinically relevant for women with sexual dysfunction than genital blood flow. This study's large sample is unique in sexual psychophysiology, and it strengthens the credibility of the findings. However, this study is limited in that arousal-specific dysfunction was determined with self-report measures, not by a clinician-administered assessment. These findings suggest distinct response trajectories in women with and without sexual dysfunction, and although perceived genital responses are important for women who are experiencing problems with arousal, they do not seem to be related to objective measures of physiologic arousal. Handy AB, Stanton AM, Pulverman CS, Meston CM. Differences in Perceived and Physiologic Genital Arousal Between Women With and Without Sexual Dysfunction. J Sex Med 2018;15:52-63. Copyright © 2017 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  18. Measurement of pixel response functions of a fully depleted CCD

    NASA Astrophysics Data System (ADS)

    Kobayashi, Yukiyasu; Niwa, Yoshito; Yano, Taihei; Gouda, Naoteru; Hara, Takuji; Yamada, Yoshiyuki

    2014-07-01

    We describe the measurement of detailed and precise Pixel Response Functions (PRFs) of a fully depleted CCD. Measurements were performed under different physical conditions, such as different wavelength light sources or CCD operating temperatures. We determined the relations between these physical conditions and the forms of the PRF. We employ two types of PRFs: one is the model PRF (mPRF) that can represent the shape of a PRF with one characteristic parameter and the other is the simulated PRF (sPRF) that is the resultant PRF from simulating physical phenomena. By using measured, model, and simulated PRFs, we determined the relations between operational parameters and the PRFs. Using the obtained relations, we can now estimate a PRF under conditions that will be encountered during the course of Nano-JASMINE observations. These estimated PRFs will be utilized in the analysis of the Nano-JASMINE data.

  19. Relationships of vascular function with measures of ambulatory blood pressure variation.

    PubMed

    Hodgson, Jonathan M; Woodman, Richard J; Croft, Kevin D; Ward, Natalie C; Bondonno, Catherine P; Puddey, Ian B; Lukoshkova, Elena V; Head, Geoffrey A

    2014-03-01

    Characteristics of short-term blood pressure (BP) variation may influence cardiovascular disease risk via effects on vascular function. In a cross-sectional study of a group of treated hypertensive and untreated largely normotensive subjects we investigated the relationships of measures of short-term BP variation with brachial artery vasodilator function. A total of 163 treated hypertensive (n = 91) and untreated largely normotensive (n = 72) men and women were recruited from the general population. Measures of systolic and diastolic BP variation were calculated from 24 h ambulatory BP assessments and included: (i) rate of measurement-to-measurement BP variation (SBP-var and DBP-var); and (ii) day-to-night BP dip (SBP-dip and DBP dip). Endothelium-dependent vasodilation was assessed as flow-mediated dilation (FMD) and endothelium-independent vasodilation was assessed in response to glyceryl trinitrate (GTN). Relationships were explored using univariate and multivariate linear regression. The relationships of brachial artery vasodilator function with BP variation were not significantly different between treated hypertensive and untreated subjects, therefore these groups were combined for analysis. In univariate analysis, higher SBP-var (P < 0.001) and lower DBP-dip (P = 0.004) were associated with lower FMD; and higher SBP-var (P = 0.002) and lower SBP-dip (P = 0.003) and DBP-dip (P = 0.001) were associated with lower GTN-mediated dilation. In multivariate analysis, lower SBP-dip (P = 0.007) and DBP-dip (P = 0.03) were independently associated with lower GTN response. Our results indicate that a lower day-to-night BP dip is independently associated with impaired smooth muscle cell function. Although rate of BP variation was associated with measures of endothelial and smooth muscle cell function, relationships were attenuated after accounting for age and BP. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. Effects of Stimulus Intensity on Low-Frequency Toneburst Cochlear Microphonic Waveforms.

    PubMed

    Zhang, Ming

    2013-01-02

    This study investigates changes in amplitude and delays in low-frequency toneburst cochlear microphonic (CM) waveforms recorded at the ear canal in response to different stimulus intensities. Ten volunteers aged 20-30 were recruited. Low-frequency CM waveforms at 500 Hz in response to a 14-ms toneburst were recorded from an ear canal electrode using electrocochleography techniques. The data was statistically analyzed in order to confirm whether the differences were significant in the effects of stimulus intensity on the amplitudes and delays of the low-frequency CM waveforms. Electromagnetic interference artifacts can jeopardize CM measurements but such artifacts can be avoided. The CM waveforms can be recorded at the ear canal in response to a toneburst which is longer than that used in ABR measurements. The CM waveforms thus recorded are robust, and the amplitude of CM waveforms is intensity-dependent. In contrast, the delay of CM waveforms is intensity-independent, which is different from neural responses as their delay or latency is intensity-dependent. These findings may be useful for development of the application of CM measurement as a supplementary approach to otoacoustic emission (OAE) measurement in the clinic which is severely affected by background acoustic noise. The development of the application in the assessment of low-frequency cochlear function may become possible if a further series of studies can verify the feasibility, but it is not meant to be a substitute for audiometry or OAE measurements. The measurement of detection threshold of CM waveform responses using growth function approach may become possible in the clinic. The intensity-independent nature of CMs with regards to delay measurements may also become an impacting factor for differential diagnoses and for designing new research studies.

  1. Minus-Lens–Stimulated Accommodative Amplitude Decreases Sigmoidally with Age: A Study of Objectively Measured Accommodative Amplitudes from Age 3

    PubMed Central

    Anderson, Heather A.; Hentz, Gloria; Glasser, Adrian; Stuebing, Karla K.; Manny, Ruth E.

    2009-01-01

    Purpose Guidelines for predicting accommodative amplitude by age are often based on subjective push-up test data that overestimate the accommodative response. Studies in which objective measurements were used have defined expected amplitudes for adults, but expected amplitudes for children remain unknown. In this study, objective methods were used to measure accommodative amplitude in a wide age range of individuals, to define the relationship of amplitude and age from age 3. Methods Accommodative responses were measured in 140 subjects aged 3 to 40 years. Measurements were taken with the Grand Seiko autorefractor (RyuSyo Industrial Co., Ltd., Kagawa, Japan) as the subjects viewed a high-contrast target at 33 cm through minus lenses of increasing power until the responses showed no further increase in accommodation. Results The maximum accommodative amplitude of each subject was plotted by age, and a curvilinear function fit to the data: y = 7.33 − 0.0035(age − 3)2 (P < 0.001). Tangent analysis of the fit indicated that the accommodative amplitude remained relatively stable until age 20. Data from this study were then pooled with objective amplitudes from previous studies of adults up to age 70. A sigmoidal function was fit to the data: y = 7.083/(1 + e[0.2031(age-36.2)−0.6109]) (P < 0.001). The sigmoidal function indicated relatively stable amplitudes below age 20 years, a rapid linear decline between 20 and 50 years, and a taper to 0 beyond 50 years. Conclusions These data indicate that accommodative amplitude decreases in a curvilinear manner from 3 to 40 years. When combined with data from previous studies, a sigmoidal function describes the overall trend throughout life with the biggest decrease occurring between 20 and 50 years. PMID:18326693

  2. Stability in neurovascular function at 3800m.

    PubMed

    Caldwell, Hannah G; Ainslie, Philip N; Ellis, Lindsay A; Phillips, Aaron A; Flück, Daniela

    2017-12-01

    Hypoxia-induced neurocognitive impairments have been of clinical interest for centuries. The mechanisms responsible for these neurocognitive impairments at altitude are unclear, but may relate to the uncoupling of local neural activity with appropriate changes in cerebral blood flow (CBF; i.e., functional hyperemia). At both sea level and following 3 and 7days at 3800m (Barcroft Research Lab, White Mountain, CA, USA), transcranial Doppler was used to index CBF during three separate tasks designed to evoke cerebral functional hyperemia in 11 healthy individuals (26.6±5.5yrs, 2 females). The tasks were: 1) Visual stimulation (VS), with measurement of anterior and posterior CBF; 2) Verbal fluency (VF), with measurement of bilateral CBF; and 3) Visuospatial task (VST), with measurement of bilateral CBF. The VS evoked an increase from baseline to percent peak response in both the posterior (15.2±7.7%, P<0.01) and anterior (7.6±3.5%, P<0.01) cerebral hemispheres; however, the percent peak response was higher in the posterior brain, where visual regions are localized (P=0.01). The left-sided task, VF, resulted in an increase in both the left (12.2±4.0%, P<0.01) and right (9.0±4.4%, P<0.01) cerebral hemispheres; however, the percent peak response was higher in the left brain, where language centers are located (P<0.01). The right-sided task, VST, evoked an increase in both the left (13.9±7.1%, P<0.01) and right (16.8±6.7%, P<0.01) cerebral hemispheres; however, the percent peak response was higher in the right brain, where visuospatial regions are located (P<0.01). Each cerebral functional hyperemia response for all three tasks was unaffected by high altitude exposure (P>0.05). Overall, at least at 3800m, neurovascular function is intact with exposure to 3 and 7days of high altitude and likely does not explain the previous reports of neurocognitive impairment. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Harmful or helpful: perceived solicitous and facilitative partner responses are differentially associated with pain and sexual satisfaction in women with provoked vestibulodynia.

    PubMed

    Rosen, Natalie O; Bergeron, Sophie; Glowacka, Maria; Delisle, Isabelle; Baxter, Mary Lou

    2012-09-01

    Provoked vestibulodynia (PVD) is a highly prevalent vulvovaginal pain condition that negatively affects women's emotional, sexual, and relationship well-being. Recent studies have investigated the role of interpersonal variables, including partner responses. We examined whether solicitous and facilitative partner responses were differentially associated with vulvovaginal pain and sexual satisfaction in women with PVD by examining each predictor while controlling for the other. One hundred twenty-one women (M age = 30.60, SD = 10.53) with PVD or self-reported symptoms of PVD completed the solicitous subscale of the spouse response scale of the Multidimensional Pain Inventory, and the facilitative subscale of the Spouse Response Inventory. Participants also completed measures of pain, sexual function, sexual satisfaction, trait anxiety, and avoidance of pain and sexual behaviors (referred to as "avoidance"). Dependent measures were the (i) Pain Rating Index of the McGill Pain Questionnaire with reference to pain during vaginal intercourse and (ii) Global Measure of Sexual Satisfaction Scale. Controlling for trait anxiety and avoidance, higher solicitous partner responses were associated with higher vulvovaginal pain intensity (β = 0.20, P = 0.03), and higher facilitative partner responses were associated with lower pain intensity (β = -0.20, P = 0.04). Controlling for sexual function, trait anxiety, and avoidance, higher facilitative partner responses were associated with higher sexual satisfaction (β = 0.15, P = 0.05). Findings suggest that facilitative partner responses may aid in alleviating vulvovaginal pain and improving sexual satisfaction, whereas solicitous partner responses may contribute to greater pain. © 2012 International Society for Sexual Medicine.

  4. Comparison of robotics, functional electrical stimulation, and motor learning methods for treatment of persistent upper extremity dysfunction after stroke: a randomized controlled trial.

    PubMed

    McCabe, Jessica; Monkiewicz, Michelle; Holcomb, John; Pundik, Svetlana; Daly, Janis J

    2015-06-01

    To compare response to upper-limb treatment using robotics plus motor learning (ML) versus functional electrical stimulation (FES) plus ML versus ML alone, according to a measure of complex functional everyday tasks for chronic, severely impaired stroke survivors. Single-blind, randomized trial. Medical center. Enrolled subjects (N=39) were >1 year postsingle stroke (attrition rate=10%; 35 completed the study). All groups received treatment 5d/wk for 5h/d (60 sessions), with unique treatment as follows: ML alone (n=11) (5h/d partial- and whole-task practice of complex functional tasks), robotics plus ML (n=12) (3.5h/d of ML and 1.5h/d of shoulder/elbow robotics), and FES plus ML (n=12) (3.5h/d of ML and 1.5h/d of FES wrist/hand coordination training). Primary measure: Arm Motor Ability Test (AMAT), with 13 complex functional tasks; secondary measure: upper-limb Fugl-Meyer coordination scale (FM). There was no significant difference found in treatment response across groups (AMAT: P≥.584; FM coordination: P≥.590). All 3 treatment groups demonstrated clinically and statistically significant improvement in response to treatment (AMAT and FM coordination: P≤.009). A group treatment paradigm of 1:3 (therapist/patient) ratio proved feasible for provision of the intensive treatment. No adverse effects. Severely impaired stroke survivors with persistent (>1y) upper-extremity dysfunction can make clinically and statistically significant gains in coordination and functional task performance in response to robotics plus ML, FES plus ML, and ML alone in an intensive and long-duration intervention; no group differences were found. Additional studies are warranted to determine the effectiveness of these methods in the clinical setting. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  5. Radiation-induced changes in gustatory function comparison of effects of neutron and photon irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mossman, K.L.; Chencharick, J.D.; Scheer, A.C.

    1979-04-01

    Changes in gustatory function were measured in 51 patients with various forms of cancer who received radiation to the head and neck region. Forty patients (group I) were treated with conventional photon radiation (e.g. 66 Gy/7 weeks), and 11 patients (group II) were treated with cyclotron produced fast neutrons (e.g. 22 Gy/7 weeks). Taste acuity was measured for four taste qualities (salt, sweet, sour, and bitter) by a forced choice-three stimulus drop technique which measured detection and recognition thresholds and by a forced scaling technique which measured taste intensity responsiveness. Subjective complaints of anorexia, dysgeusia, taste loss, and xerostomia weremore » also recorded. Patients were studied before, during and up to two months after therapy. Prior to therapy, detection and recognition thresholds, intensity responsiveness, and the frequency of subjective complaints in patients from groups I and II were statistically equivalent. During and up to 2 months after therapy, taste impairment and frequency of subjective complaints increased significantly in neutron and photon treated patients, but were statistically equivalent. Results of this study indicate that gustatory tissue response as measured by taste detection and recognition and intensity responsiveness, and the frequency of subjective complaints related to taste are statistically equivalent in patients before, during, or up 2 months after they were given either neutron or photon radiation for tumors of the head and neck.« less

  6. Quantum efficiency measurements of eROSITA pnCCDs

    NASA Astrophysics Data System (ADS)

    Ebermayer, Stefanie; Andritschke, Robert; Elbs, Johannes; Meidinger, Norbert; Strüder, Lothar; Hartmann, Robert; Gottwald, Alexander; Krumrey, Michael; Scholze, Frank

    2010-07-01

    For the eROSITA X-ray telescope, which is planned to be launched in 2012, detectors were developed and fabricated at the MPI Semiconductor Laboratory. The fully depleted, back-illuminated pnCCDs have an ultrathin pn-junction to improve the low-energy X-ray response function and quantum efficiency. The device thickness of 450 μm is fully sensitive to X-ray photons yielding high quantum efficiency of more than 90% at photon energies of 10 keV. An on-chip filter is deposited on top of the entrance window to suppress visible and UV light which would interfere with the X-ray observations. The pnCCD type developed for the eROSITA telescope was characterized in terms of quantum efficiency and spectral response function. The described measurements were performed in 2009 at the synchrotron radiation sources BESSY II and MLS as cooperation between the MPI Semiconductor Laboratory and the Physikalisch-Technische Bundesanstalt (PTB). Quantum efficiency measurements over a wide range of photon energies from 3 eV to 11 keV as well as spectral response measurements are presented. For X-ray energies from 3 keV to 10 keV the quantum efficiency of the CCD including on-chip filter is shown to be above 90% with an attenuation of visible light of more than five orders of magnitude. A detector response model is described and compared to the measurements.

  7. Form and function in hillslope hydrology: characterization of subsurface flow based on response observations

    NASA Astrophysics Data System (ADS)

    Angermann, Lisa; Jackisch, Conrad; Allroggen, Niklas; Sprenger, Matthias; Zehe, Erwin; Tronicke, Jens; Weiler, Markus; Blume, Theresa

    2017-07-01

    The phrase form and function was established in architecture and biology and refers to the idea that form and functionality are closely correlated, influence each other, and co-evolve. We suggest transferring this idea to hydrological systems to separate and analyze their two main characteristics: their form, which is equivalent to the spatial structure and static properties, and their function, equivalent to internal responses and hydrological behavior. While this approach is not particularly new to hydrological field research, we want to employ this concept to explicitly pursue the question of what information is most advantageous to understand a hydrological system. We applied this concept to subsurface flow within a hillslope, with a methodological focus on function: we conducted observations during a natural storm event and followed this with a hillslope-scale irrigation experiment. The results are used to infer hydrological processes of the monitored system. Based on these findings, the explanatory power and conclusiveness of the data are discussed. The measurements included basic hydrological monitoring methods, like piezometers, soil moisture, and discharge measurements. These were accompanied by isotope sampling and a novel application of 2-D time-lapse GPR (ground-penetrating radar). The main finding regarding the processes in the hillslope was that preferential flow paths were established quickly, despite unsaturated conditions. These flow paths also caused a detectable signal in the catchment response following a natural rainfall event, showing that these processes are relevant also at the catchment scale. Thus, we conclude that response observations (dynamics and patterns, i.e., indicators of function) were well suited to describing processes at the observational scale. Especially the use of 2-D time-lapse GPR measurements, providing detailed subsurface response patterns, as well as the combination of stream-centered and hillslope-centered approaches, allowed us to link processes and put them in a larger context. Transfer to other scales beyond observational scale and generalizations, however, rely on the knowledge of structures (form) and remain speculative. The complementary approach with a methodological focus on form (i.e., structure exploration) is presented and discussed in the companion paper by Jackisch et al.(2017).

  8. Semi-empirical and phenomenological instrument functions for the scanning tunneling microscope

    NASA Astrophysics Data System (ADS)

    Feuchtwang, T. E.; Cutler, P. H.; Notea, A.

    1988-08-01

    Recent progress in the development of a convenient algorithm for the determination of a quantitative local density of states (LDOS) of the sample, from data measured in the STM, is reviewd. It is argued that the sample LDOS strikes a good balance between the information content of a surface characteristic and effort required to obtain it experimentally. Hence, procedures to determine the sample LDOS as directly and as tip-model independently as possible are emphasized. The solution of the STM's "inverse" problem in terms of novel versions of the instrument (or Green) function technique is considered in preference to the well known, more direct solutions. Two types of instrument functions are considered: Approximations of the basic tip-instrument function obtained from the transfer Hamiltonian theory of the STM-STS. And, phenomenological instrument functions devised as a systematic scheme for semi-empirical first order corrections of "ideal" models. The instrument function, in this case, describes the corrections as the response of an independent component of the measuring apparatus inserted between the "ideal" instrument and the measured data. This linear response theory of measurement is reviewed and applied. A procedure for the estimation of the consistency of the model and the systematic errors due to the use of an approximate instrument function is presented. The independence of the instrument function techniques from explicit microscopic models of the tip is noted. The need for semi-empirical, as opposed to strictly empirical or analytical determination of the instrument function is discussed. The extension of the theory to the scanning tunneling spectrometer is noted, as well as its use in a theory of resolution.

  9. Cardiac Function in Young and Old Little Mice

    PubMed Central

    Reddy, Anilkumar K.; Amador-Noguez, Daniel; Darlington, Gretchen J.; Scholz, Beth A.; Michael, Lloyd H.; Hartley, Craig J.; Entman, Mark L.; Taffet, George E.

    2009-01-01

    We studied cardiac function in young and old, wild-type (WT), and longer-living Little mice using cardiac flow velocities, echocardiographic measurements, and left ventricular (LV) pressure (P) to determine if enhanced reserves were in part responsible for longevity in these mice. Resting/baseline cardiac function, as measured by velocities, LV dimensions, +dP/dtmax, and −dP/dtmax, was significantly lower in young Little mice versus young WT mice. Fractional shortening (FS) increased significantly, and neither +dP/dtmax nor −dP/dtmax declined with age in Little mice. In contrast, old WT mice had no change in FS but had significantly lower +dP/dtmax and −dP/dtmax versus young WT mice. Significant decreases were observed in the velocity indices of old Little mice versus old WT mice, but other parameters were unchanged. The magnitude of dobutamine stress response remained unchanged with age in Little mice, while that in WT mice decreased. These data suggest that while resting cardiac function in Little mice versus WT mice is lower at young age, it is relatively unaltered with aging. Additionally, cardiac function in response to stress was maintained with age in Little mice but not in their WT counterparts. Thus, some mouse models of increased longevity may not be associated with enhanced reserves. PMID:18166681

  10. Somatosensory cortex functional connectivity abnormalities in autism show opposite trends, depending on direction and spatial scale

    PubMed Central

    Khan, Sheraz; Michmizos, Konstantinos; Tommerdahl, Mark; Ganesan, Santosh; Kitzbichler, Manfred G.; Zetino, Manuel; Garel, Keri-Lee A.; Herbert, Martha R.; Hämäläinen, Matti S.

    2015-01-01

    Functional connectivity is abnormal in autism, but the nature of these abnormalities remains elusive. Different studies, mostly using functional magnetic resonance imaging, have found increased, decreased, or even mixed pattern functional connectivity abnormalities in autism, but no unifying framework has emerged to date. We measured functional connectivity in individuals with autism and in controls using magnetoencephalography, which allowed us to resolve both the directionality (feedforward versus feedback) and spatial scale (local or long-range) of functional connectivity. Specifically, we measured the cortical response and functional connectivity during a passive 25-Hz vibrotactile stimulation in the somatosensory cortex of 20 typically developing individuals and 15 individuals with autism, all males and right-handed, aged 8–18, and the mu-rhythm during resting state in a subset of these participants (12 per group, same age range). Two major significant group differences emerged in the response to the vibrotactile stimulus. First, the 50-Hz phase locking component of the cortical response, generated locally in the primary (S1) and secondary (S2) somatosensory cortex, was reduced in the autism group (P < 0.003, corrected). Second, feedforward functional connectivity between S1 and S2 was increased in the autism group (P < 0.004, corrected). During resting state, there was no group difference in the mu-α rhythm. In contrast, the mu-β rhythm, which has been associated with feedback connectivity, was significantly reduced in the autism group (P < 0.04, corrected). Furthermore, the strength of the mu-β was correlated to the relative strength of 50 Hz component of the response to the vibrotactile stimulus (r = 0.78, P < 0.00005), indicating a shared aetiology for these seemingly unrelated abnormalities. These magnetoencephalography-derived measures were correlated with two different behavioural sensory processing scores (P < 0.01 and P < 0.02 for the autism group, P < 0.01 and P < 0.0001 for the typical group), with autism severity (P < 0.03), and with diagnosis (89% accuracy). A biophysically realistic computational model using data driven feedforward and feedback parameters replicated the magnetoencephalography data faithfully. The direct observation of both abnormally increased and abnormally decreased functional connectivity in autism occurring simultaneously in different functional connectivity streams, offers a potential unifying framework for the unexplained discrepancies in current findings. Given that cortical feedback, whether local or long-range, is intrinsically non-linear, while cortical feedforward is generally linear relative to the stimulus, the present results suggest decreased non-linearity alongside an increased veridical component of the cortical response in autism. PMID:25765326

  11. A novel method to produce nonlinear empirical physical formulas for experimental nonlinear electro-optical responses of doped nematic liquid crystals: Feedforward neural network approach

    NASA Astrophysics Data System (ADS)

    Yildiz, Nihat; San, Sait Eren; Okutan, Mustafa; Kaya, Hüseyin

    2010-04-01

    Among other significant obstacles, inherent nonlinearity in experimental physical response data poses severe difficulty in empirical physical formula (EPF) construction. In this paper, we applied a novel method (namely layered feedforward neural network (LFNN) approach) to produce explicit nonlinear EPFs for experimental nonlinear electro-optical responses of doped nematic liquid crystals (NLCs). Our motivation was that, as we showed in a previous theoretical work, an appropriate LFNN, due to its exceptional nonlinear function approximation capabilities, is highly relevant to EPF construction. Therefore, in this paper, we obtained excellently produced LFNN approximation functions as our desired EPFs for above-mentioned highly nonlinear response data of NLCs. In other words, by using suitable LFNNs, we successfully fitted the experimentally measured response and predicted the new (yet-to-be measured) response data. The experimental data (response versus input) were diffraction and dielectric properties versus bias voltage; and they were all taken from our previous experimental work. We conclude that in general, LFNN can be applied to construct various types of EPFs for the corresponding various nonlinear physical perturbation (thermal, electronic, molecular, electric, optical, etc.) data of doped NLCs.

  12. Effects of Peripheral Vestibular Dysfunction on Dynamic Postural Stability Measured by the Functional Reach Test and Timed Up and Go Test.

    PubMed

    Nishi, Toshiko; Kamogashira, Teru; Fujimoto, Chisato; Kinoshita, Makoto; Egami, Naoya; Sugasawa, Keiko; Yamasoba, Tatsuya; Iwasaki, Shinichi

    2017-06-01

    To investigate the influence of vestibular function on dynamic postural stability assessed by the functional reach test (FRT) and the timed up and go test (TUG). Retrospective study. Tertiary referral center. The FRT and TUG were performed in 399 patients with dizziness. The effects of peripheral vestibular dysfunction assessed by the caloric test and cervical vestibular evoked myogenic potentials (cVEMPs) to air-conducted sound (500 Hz, tone burst) on the results of FRT and TUG were analyzed. Neither FRT nor TUG scores showed significant differences in relation to the results of the caloric test ( P > .3). The FRT scores in patients who showed abnormal cVEMP responses on both sides were significantly smaller than those in patients who showed normal cVEMP responses ( P < .01). The TUG scores in patients who showed abnormal cVEMP responses on both sides were significantly greater than those in patients who showed normal cVEMP responses ( P < .05). The vestibulo-spinal reflex mediated by the saccule and its afferents is one of the factors that influence the maintenance of dynamic postural stability as measured by FRT and TUG.

  13. Evaluating Cellular Polyfunctionality with a Novel Polyfunctionality Index

    PubMed Central

    Larsen, Martin; Sauce, Delphine; Arnaud, Laurent; Fastenackels, Solène; Appay, Victor; Gorochov, Guy

    2012-01-01

    Functional evaluation of naturally occurring or vaccination-induced T cell responses in mice, men and monkeys has in recent years advanced from single-parameter (e.g. IFN-γ-secretion) to much more complex multidimensional measurements. Co-secretion of multiple functional molecules (such as cytokines and chemokines) at the single-cell level is now measurable due primarily to major advances in multiparametric flow cytometry. The very extensive and complex datasets generated by this technology raise the demand for proper analytical tools that enable the analysis of combinatorial functional properties of T cells, hence polyfunctionality. Presently, multidimensional functional measures are analysed either by evaluating all combinations of parameters individually or by summing frequencies of combinations that include the same number of simultaneous functions. Often these evaluations are visualized as pie charts. Whereas pie charts effectively represent and compare average polyfunctionality profiles of particular T cell subsets or patient groups, they do not document the degree or variation of polyfunctionality within a group nor does it allow more sophisticated statistical analysis. Here we propose a novel polyfunctionality index that numerically evaluates the degree and variation of polyfuntionality, and enable comparative and correlative parametric and non-parametric statistical tests. Moreover, it allows the usage of more advanced statistical approaches, such as cluster analysis. We believe that the polyfunctionality index will render polyfunctionality an appropriate end-point measure in future studies of T cell responsiveness. PMID:22860124

  14. Characterization and Comparison of Vibration Transfer Paths in a Helicopter Gearbox and a Fixture Mounted Gearbox

    NASA Technical Reports Server (NTRS)

    Islam, Akm Anwarul; Dempsey, Paula J.; Feldman, Jason; Larsen, Chris

    2014-01-01

    Health monitoring of rotorcraft components, currently being performed by Health and Usage Monitoring Systems through analyses of vibration signatures of dynamic mechanical components, is very important for their safe and economic operation. HUMS analyze vibration signatures associated with faults and quantify them as condition indicators to predict component behavior. Vibration transfer paths are characterized by frequency response functions derived from the input/output relationship between applied force and dynamic response through a structure as a function of frequency. With an objective to investigate the differences in transfer paths, transfer path measurements were recorded under similar conditions in the left and right nose gearboxes of an AH-64 helicopter and in an isolated left nose gearbox in a test fixture at NASA Glenn Research Center. The test fixture enabled the application of measured torques-common during an actual operation. An impact hammer as well as commercial and lab piezo shakers, were used in conjunction with two types of commercially available accelerometers to collect the vibration response under various test conditions. The frequency response functions measured under comparable conditions of both systems were found to be consistent. Measurements made on the fixture indicated certain real-world installation and maintenance issues, such as sensor alignments, accelerometer locations and installation torques, had minimal effect. However, gear vibration transfer path dynamics appeared to be somewhat dependent on the presence of oil, and the transfer path dynamics were notably different if the force input was on the internal ring gear rather than on the external gearbox case.

  15. Anatomical and functional assessment of brown adipose tissue by magnetic resonance imaging.

    PubMed

    Chen, Y Iris; Cypess, Aaron M; Sass, Christina A; Brownell, Anna-Liisa; Jokivarsi, Kimmo T; Kahn, C Ronald; Kwong, Kenneth K

    2012-07-01

    Brown adipose tissue (BAT) is the primary tissue responsible for nonshivering thermogenesis in mammals. The amount of BAT and its level of activation help regulate the utilization of excessive calories for thermogenesis as opposed to storage in white adipose tissue (WAT) which would lead to weight gain. Over the past several years, BAT activity in vivo has been primarily assessed by positron emission tomography-computed tomography (PET-CT) scan using 2-[18F]-fluoro-2-deoxy-D-glucose (18F-FDG) to measure glucose utilization associated with BAT mitochondrial respiration. In this study, we demonstrate the feasibility of mapping and estimating BAT volume and metabolic function in vivo in rats at a 9.4T magnetic resonance imaging (MRI) scanner using sequences available from clinical MR scanners. Based on the morphological characteristics of BAT, we measured the volume distribution of BAT with MRI sequences that have strong fat-water contrast. We also investigated BAT volume by utilizing spin-echo MRI sequences. The in vivo MRI-estimated BAT volumes were correlated with direct measurement of BAT mass from dissected samples. Using MRI, we also were able to map hemodynamic responses to changes in BAT metabolism induced pharmacologically by β3-adrenergic receptor agonist, CL-316,243 and compare this to BAT activity in response to CL-316,243 assessed by PET 18F-FDG. In conclusion, we demonstrate the feasibility of measuring BAT volume and function in vivo using routine MRI sequences. The MRI measurement of BAT volume is consistent with quantitative measurement of the tissue ex vivo.

  16. Model of the transient neurovascular response based on prompt arterial dilation

    PubMed Central

    Kim, Jung Hwan; Khan, Reswanul; Thompson, Jeffrey K; Ress, David

    2013-01-01

    Brief neural stimulation results in a stereotypical pattern of vascular and metabolic response that is the basis for popular brain-imaging methods such as functional magnetic resonance imagine. However, the mechanisms of transient oxygen transport and its coupling to cerebral blood flow (CBF) and oxygen metabolism (CMRO2) are poorly understood. Recent experiments show that brief stimulation produces prompt arterial vasodilation rather than venous vasodilation. This work provides a neurovascular response model for brief stimulation based on transient arterial effects using one-dimensional convection–diffusion transport. Hemoglobin oxygen dissociation is included to enable predictions of absolute oxygen concentrations. Arterial CBF response is modeled using a lumped linear flow model, and CMRO2 response is modeled using a gamma function. Using six parameters, the model successfully fit 161/166 measured extravascular oxygen time courses obtained for brief visual stimulation in cat cerebral cortex. Results show how CBF and CMRO2 responses compete to produce the observed features of the hemodynamic response: initial dip, hyperoxic peak, undershoot, and ringing. Predicted CBF and CMRO2 response amplitudes are consistent with experimental measurements. This model provides a powerful framework to quantitatively interpret oxygen transport in the brain; in particular, its intravascular oxygen concentration predictions provide a new model for fMRI responses. PMID:23756690

  17. Content range and precision of a computer adaptive test of upper extremity function for children with cerebral palsy.

    PubMed

    Montpetit, Kathleen; Haley, Stephen; Bilodeau, Nathalie; Ni, Pengsheng; Tian, Feng; Gorton, George; Mulcahey, M J

    2011-02-01

    This article reports on the content range and measurement precision of an upper extremity (UE) computer adaptive testing (CAT) platform of physical function in children with cerebral palsy. Upper extremity items representing skills of all abilities were administered to 305 parents. These responses were compared with two traditional standardized measures: Pediatric Outcomes Data Collection Instrument and Functional Independence Measure for Children. The UE CAT correlated strongly with the upper extremity component of these measures and had greater precision when describing individual functional ability. The UE item bank has wider range with items populating the lower end of the ability spectrum. This new UE item bank and CAT have the capability to quickly assess children of all ages and abilities with good precision and, most importantly, with items that are meaningful and appropriate for their age and level of physical function.

  18. Data equivalency of an interactive voice response system for home assessment of back pain and function.

    PubMed

    Shaw, William S; Verma, Santosh K

    2007-01-01

    Interactive voice response (IVR) systems that collect survey data using automated, push-button telephone responses may be useful to monitor patients' pain and function at home; however, its equivalency to other data collection methods has not been studied. To study the data equivalency of IVR measurement of pain and function to live telephone interviewing. In a prospective cohort study, 547 working adults (66% male) with acute back pain were recruited at an initial outpatient visit and completed telephone assessments one month later to track outcomes of pain, function, treatment helpfulness and return to work. An IVR system was introduced partway through the study (after the first 227 participants) to reduce the staff time necessary to contact participants by telephone during nonworking hours. Of 368 participants who were subsequently recruited and offered the IVR option, 131 (36%) used IVR, 189 (51%) were contacted by a telephone interviewer after no IVR attempt was made within five days, and 48 (13%) were lost to follow-up. Those with lower income were more likely to use IVR. Analysis of outcome measures showed that IVR respondents reported comparatively lower levels of function and less effective treatment, but not after controlling for differences due to the delay in reaching non-IVR users by telephone (mean: 35.4 versus 29.2 days). The results provided no evidence of information or selection bias associated with IVR use; however, IVR must be supplemented with other data collection options to maintain high response rates.

  19. Effects of Alcohol on Tests of Executive Functioning in Men and Women: A Dose Response Examination

    PubMed Central

    Guillot, Casey R.; Fanning, Jennifer R.; Bullock, Joshua S.; McCloskey, Michael S.; Berman, Mitchell E.

    2014-01-01

    Alcohol has been shown to affect performance on tasks associated with executive functioning. However, studies in this area have generally been limited to a single dose or gender or have used small sample sizes. The purpose of this study was to provide a more nuanced and systematic examination of alcohol's effects on commonly used tests of executive functioning at multiple dosages in both men and women. Research volunteers (91 women and 94 men) were randomly assigned to one of four drink conditions (alcohol doses associated with target blood alcohol concentrations of .000%, .050%, .075% and .100%). Participants then completed three tasks comprising two domains of executive functioning: two set shifting tasks, the Trail Making Test and a computerized version of the Wisconsin Card Sorting Task, and a response inhibition task, the GoStop Impulsivity Paradigm. Impaired performance on set shifting tasks was found at the .100% and .075% dosages, but alcohol intoxication did not impair performance on the GoStop. No gender effects emerged. Thus, alcohol negatively affects set shifting at moderately high levels of intoxication in both men and women, likely due to alcohol's interference with prefrontal cortex function. Although it is well-established that alcohol negatively affects response inhibition as measured by auditory stop-signal tasks, alcohol does not appear to exert a negative effect on response inhibition as measured by the GoStop, a visual stop-signal task. PMID:20939644

  20. Implementation of the New Approach for the Dose-Response Functions Development for the Case of Athens and Greece

    NASA Astrophysics Data System (ADS)

    Christodoulakis, J.; Tzanis, C. G.; Varotsos, C. A.; Kouremadas, G.

    2016-08-01

    Dose-response functions (DRFs) are functions used for estimating corrosion and/or soiling levels of materials used in constructions and cultural monuments. In order to achieve this, DRFs lean on ground-based measurements of specific air pollution and climatic parameters like nitrogen oxides, ozone, temperature and others. In DRAGON 3 2015 Symposium we presented a new approach which proposed a technique for using satellite-based data for the necessary parameters instead of ground-based expanding in this way: a) the usage of DRFs in cases/areas where there is no availability of in situ measurements, b) the applicability of satellite-based data. In this work we present mapping results of deterioration levels (corrosion and soiling) for the case of Athens, Greece but also for the whole Greece country.

  1. Measurements of electron detection efficiencies in solid state detectors.

    NASA Technical Reports Server (NTRS)

    Lupton, J. E.; Stone, E. C.

    1972-01-01

    Detailed laboratory measurement of the electron response of solid state detectors as a function of incident electron energy, detector depletion depth, and energy-loss discriminator threshold. These response functions were determined by exposing totally depleted silicon surface barrier detectors with depletion depths between 50 and 1000 microns to the beam from a magnetic beta-ray spectrometer. The data were extended to 5000 microns depletion depth using the results of previously published Monte Carlo electron calculations. When the electron counting efficiency of a given detector is plotted as a function of energy-loss threshold for various incident energies, the efficiency curves are bounded by a smooth envelope which represents the upper limit to the detection efficiency. These upper limit curves, which scale in a simple way, make it possible to easily estimate the electron sensitivity of solid-state detector systems.

  2. Characterization of Deuterated-xylene Scintillator as a Neutron Spectrometer

    DOE PAGES

    Di Fulvio, Angela; Becchetti, F. D.; Raymond, R. S.; ...

    2016-11-16

    We have experimentally characterized the neutron light output response functions of a deuterated-xylene scintillator for neutron energies lower than 10 MeV. We then used the response matrix to unfold the energy distribution of neutrons produced via several reactions, i.e. spontaneous fission, d(d,n)3He, 27Al(d,n)28Si, and 9Be(alpha,n)12C. Organic scintillators based on deuterated compounds show a fast response and good gamma-neutron discrimination capability, similar to proton-based scintillators. Deuterated scintillators can also effectively provide neutron spectra by unfolding measured data with the detector response matrix, without the need of time-of-flight. Deuteron recoils, produced by elastic collisions between deuterium and impinging neutrons, are preferentially forward-scattered.more » This non-isotropic reaction results in distinct peaks in the response functions to monoenergetic neutrons. In this work, we evaluated a custom-fabricated 7.62 cm x 7.62 cm deuterated-xylene (EJ301D) liquid scintillator. This liquid has a low volatility and higher flash point, compared to benzene-based deuterated detectors, e.g. EJ315 and NE230. We measured the EJ301D detector neutron response matrix (up to 6 MeV neutron energy) using an intense Cf252 source and the time-of-flight technique. The number of response functions obtained using our method is only limited by counting statistics and by the experimentally achievable energy resolution. Multi-channel unfolding was performed successfully for neutron spectra with different energy spectra.« less

  3. Cognitive-behavioral therapy for children with functional abdominal pain and their parents decreases pain and other symptoms.

    PubMed

    Levy, Rona L; Langer, Shelby L; Walker, Lynn S; Romano, Joan M; Christie, Dennis L; Youssef, Nader; DuPen, Melissa M; Feld, Andrew D; Ballard, Sheri A; Welsh, Ericka M; Jeffery, Robert W; Young, Melissa; Coffey, Melissa J; Whitehead, William E

    2010-04-01

    Unexplained abdominal pain in children has been shown to be related to parental responses to symptoms. This randomized controlled trial tested the efficacy of an intervention designed to improve outcomes in idiopathic childhood abdominal pain by altering parental responses to pain and children's ways of coping and thinking about their symptoms. Two hundred children with persistent functional abdominal pain and their parents were randomly assigned to one of two conditions-a three-session intervention of cognitive-behavioral treatment targeting parents' responses to their children's pain complaints and children's coping responses, or a three-session educational intervention that controlled for time and attention. Parents and children were assessed at pretreatment, and 1 week, 3 months, and 6 months post-treatment. Outcome measures were child and parent reports of child pain levels, function, and adjustment. Process measures included parental protective responses to children's symptom reports and child coping methods. Children in the cognitive-behavioral condition showed greater baseline to follow-up decreases in pain and gastrointestinal symptom severity (as reported by parents) than children in the comparison condition (time x treatment interaction, P<0.01). Also, parents in the cognitive-behavioral condition reported greater decreases in solicitous responses to their child's symptoms compared with parents in the comparison condition (time x treatment interaction, P<0.0001). An intervention aimed at reducing protective parental responses and increasing child coping skills is effective in reducing children's pain and symptom levels compared with an educational control condition.

  4. Somatosensory evoked changes in cerebral oxygen consumption measured non-invasively in premature neonates.

    PubMed

    Roche-Labarbe, Nadege; Fenoglio, Angela; Radhakrishnan, Harsha; Kocienski-Filip, Marcia; Carp, Stefan A; Dubb, Jay; Boas, David A; Grant, P Ellen; Franceschini, Maria Angela

    2014-01-15

    The hemodynamic functional response is used as a reliable marker of neuronal activity in countless studies of brain function and cognition. In newborns and infants, however, conflicting results have appeared in the literature concerning the typical response, and there is little information on brain metabolism and functional activation. Measurement of all hemodynamic components and oxygen metabolism is critical for understanding neurovascular coupling in the developing brain. To this end, we combined multiple near infrared spectroscopy techniques to measure oxy- and deoxy-hemoglobin concentrations, cerebral blood volume (CBV), and relative cerebral blood flow (CBF) in the somatosensory cortex of 6 preterm neonates during passive tactile stimulation of the hand. By combining these measures we estimated relative changes in the cerebral metabolic rate of oxygen consumption (rCMRO2). CBF starts increasing immediately after stimulus onset, and returns to baseline before blood volume. This is consistent with the model of pre-capillary arteriole active dilation driving the CBF response, with a subsequent CBV increase influenced by capillaries and veins dilating passively to accommodate the extra blood. rCMRO2 estimated using the steady-state formulation shows a biphasic pattern: an increase immediately after stimulus onset, followed by a post-stimulus undershoot due to blood flow returning faster to baseline than oxygenation. However, assuming a longer mean transit time from the arterial to the venous compartment, due to the immature vascular system of premature infants, reduces the post-stimulus undershoot and increases the flow/consumption ratio to values closer to adult values reported in the literature. We are the first to report changes in local rCBF and rCMRO2 during functional activation in preterm infants. The ability to measure these variables in addition to hemoglobin concentration changes is critical for understanding neurovascular coupling in the developing brain, and for using this coupling as a reliable functional imaging marker in neonates. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Measuring fatigue in people living with HIV/AIDS: psychometric characteristics of the HIV-Related Fatigue Scale

    PubMed Central

    BW, Pence; Barroso, J.; Leserman, J.; Harmon, J.L.; Salahuddin, N.

    2008-01-01

    In the era of life-prolonging antiretroviral therapy, chronic fatigue is one of the most prevalent and disabling symptoms of people living with HIV/AIDS, yet its measurement remains challenging. No instruments have been developed specifically to describe HIV-related fatigue. We assessed the reliability and construct validity of the HIV-Related Fatigue Scale (HRFS), a 56-item self-report instrument developed through formative qualitative research and designed to measure the intensity and consequences of fatigue as well as the circumstances surrounding fatigue in people living with HIV. The HRFS has three main scales, which measure fatigue intensity, the responsiveness of fatigue to circumstances and fatigue-related impairment of functioning. The functioning scale can be further divided into subscales measuring impairment of activities of daily living, impairment of mental functioning and impairment of social functioning. Each scale demonstrated high internal consistency (Cronbach’s alpha=0.93, 0.91 and 0.97 for the intensity, responsiveness and functioning scales, respectively). The HRFS scales also demonstrated satisfactory convergent validity when compared to other fatigue measures. HIV-Related Fatigue Scales were moderately correlated with quality of nighttime sleep (rho = 0.46, 0.47 and 0.35) but showed only weak correlations with daytime sleepiness (rho = 0.20, 0.33 and 0.18). The scales were also moderately correlated with general mental and physical health as measured by the SF-36 Health Survey (rho ranged from 0.30 to 0.68 across the 8 SF-36 subscales with most >0.40). The HRFS is a promising tool to help facilitate research on the prevalence, etiology and consequences of fatigue in people living with HIV. PMID:18608084

  6. Measuring fatigue in people living with HIV/AIDS: psychometric characteristics of the HIV-related fatigue scale.

    PubMed

    Pence, B W; Barroso, J; Leserman, J; Harmon, J L; Salahuddin, N

    2008-08-01

    In the era of life-prolonging antiretroviral therapy, chronic fatigue is one of the most prevalent and disabling symptoms of people living with HIV/AIDS, yet its measurement remains challenging. No instruments have been developed specifically to describe HIV-related fatigue. We assessed the reliability and construct validity of the HIV-Related Fatigue Scale (HRFS), a 56-item self-report instrument developed through formative qualitative research and designed to measure the intensity and consequences of fatigue as well as the circumstances surrounding fatigue in people living with HIV. The HRFS has three main scales, which measure fatigue intensity, the responsiveness of fatigue to circumstances and fatigue-related impairment of functioning. The functioning scale can be further divided into subscales measuring impairment of activities of daily living, impairment of mental functioning and impairment of social functioning. Each scale demonstrated high internal consistency (Cronbach's alpha=0.93, 0.91 and 0.97 for the intensity, responsiveness and functioning scales, respectively). The HRFS scales also demonstrated satisfactory convergent validity when compared to other fatigue measures. HIV-Related Fatigue Scales were moderately correlated with quality of nighttime sleep (rho=0.46, 0.47 and 0.35) but showed only weak correlations with daytime sleepiness (rho=0.20, 0.33 and 0.18). The scales were also moderately correlated with general mental and physical health as measured by the SF-36 Health Survey (rho ranged from 0.30 to 0.68 across the 8 SF-36 subscales with most >0.40). The HRFS is a promising tool to help facilitate research on the prevalence, etiology and consequences of fatigue in people living with HIV.

  7. Quality of Life and Bronchial Hyper-Responsiveness in Subjects With Bronchiectasis: Validation of the Seattle Obstructive Lung Disease Questionnaire in Bronchiectasis.

    PubMed

    Bulcun, Emel; Arslan, Mesut; Ekici, Aydanur; Ekici, Mehmet

    2015-11-01

    Bronchiectasis can adversely affect quality of life. However, the tests examining quality of life in bronchiectasis are not sufficient. We examined the validity of a measure designed for COPD, the Seattle Obstructive Lung Disease Questionnaire (SOLQ), in bronchiectasis. In addition, we aimed to compare the quality of life of subjects with bronchiectasis and bronchial hyper-responsiveness with that of those without to identify the effective factors. We studied 78 subjects with clinically stable bronchiectasis and 41 healthy controls matched for age and sex. Subjects were assessed by the SOLQ. A detailed history, physical examination, the Medical Outcomes Study 36-Item Short Form questionnaire, the Hospital Anxiety and Depression Scale, and spirometric measurements were obtained. Cronbach α coefficients, which reflected internal consistency, were >0.70 for all SOLQ components except for treatment satisfaction. SOLQ component scores correlated with all of the component scores of the Medical Outcomes Study 36-Item Short Form questionnaire and the Hospital Anxiety and Depression Scale, confirming their concurrent validity. All SOLQ scores correlated positively with percent-of-predicted FEV1, whereas the physical function, treatment satisfaction, and emotional function correlated negatively with the exacerbation frequency in Pearson analysis. Emotional and physical functions were positively associated with percent-of-predicted FEV1 in linear regression analysis. Compared with subjects without bronchial hyper-responsiveness, those with bronchial hyper-responsiveness had lower FEV1/FVC and more exacerbations/y. Compared with bronchiectasis subjects without bronchial hyper-responsiveness, those with bronchial hyper-responsiveness had significantly lower SOLQ, physical function, and coping skills scores but not emotional function and treatment satisfaction. The SOLQ is a valid instrument for determining quality of life in subjects with bronchiectasis. Subjects with bronchiectasis and bronchial hyper-responsiveness had a poorer quality of life, lower baseline spirometric values, and more frequent exacerbations, suggesting more severe disease. Copyright © 2015 by Daedalus Enterprises.

  8. An alternative approach to measure similarity between two deterministic transient signals

    NASA Astrophysics Data System (ADS)

    Shin, Kihong

    2016-06-01

    In many practical engineering applications, it is often required to measure the similarity of two signals to gain insight into the conditions of a system. For example, an application that monitors machinery can regularly measure the signal of the vibration and compare it to a healthy reference signal in order to monitor whether or not any fault symptom is developing. Also in modal analysis, a frequency response function (FRF) from a finite element model (FEM) is often compared with an FRF from experimental modal analysis. Many different similarity measures are applicable in such cases, and correlation-based similarity measures may be most frequently used among these such as in the case where the correlation coefficient in the time domain and the frequency response assurance criterion (FRAC) in the frequency domain are used. Although correlation-based similarity measures may be particularly useful for random signals because they are based on probability and statistics, we frequently deal with signals that are largely deterministic and transient. Thus, it may be useful to develop another similarity measure that takes the characteristics of the deterministic transient signal properly into account. In this paper, an alternative approach to measure the similarity between two deterministic transient signals is proposed. This newly proposed similarity measure is based on the fictitious system frequency response function, and it consists of the magnitude similarity and the shape similarity. Finally, a few examples are presented to demonstrate the use of the proposed similarity measure.

  9. In Search of a Visual-cortical Describing Function: a Summary of Work in Progress

    NASA Technical Reports Server (NTRS)

    Junker, A. M.; Peio, K. J.

    1984-01-01

    The thrust of the present work is to explore the utility of using a sum of sinusoids (seven or more) to obtain an evoked response and, furthermore, to see if the response is sensitive to changes in cognitive processing. Within the field of automatic control system technology, a mathematical input/output relationship for a sinusoidally stimulated nonlinear system is defined as describing function. Applying this technology, sum of sines inputs to yield describing functions for the visual-cortical response have been designed. What follows is a description of the method used to obtain visual-cortical describing functions. A number of measurement system redesigns were necessary to achieve the desired frequency resolution. Results that guided and came out of the redesigns are presented. Preliminary results of stimulus parameter effects (average intensity and depth of modulation) are also shown.

  10. T59. VIRTUAL REALTY ASSESSMENT OF FUNCTIONAL CAPACITY IN EARLY SCHIZOPHRENIA: ASSOCIATIONS WITH NEUROCOGNITION, FUNCTIONAL CAPACITY PERFORMANCE, AND DAILY FUNCTIONING

    PubMed Central

    Ventura, Joseph; Welikson, Tamara; Subotnik, Kenneth L; Ered, Arielle; Keefe, Richard; Hellemann, Gerhard H; Nuechterlein, Keith H

    2018-01-01

    Abstract Background Research using virtual reality assessment of functional capacity has shown promise as a reliable and valid way to assess treatment response in patients with established schizophrenia. There has been little work on virtual reality based assessments of functional capacity for patients in the early phase of schizophrenia. We examined whether virtual reality based assessment methods reveal functional capacity deficits in young patients and relevant relationships with established measures of neurocognition, functional capacity performance, and daily functioning. Methods The sample consisted of UCLA Aftercare Research Program patients (n=42) who were diagnosed by trained raters administering the SCID and who met criteria for schizophrenia, schizoaffective disorder, or schizophreniform disorder, and screened normal control subjects (n=13). Patients were within 2 years of their first psychotic episode upon clinic entry, were an average of 23.2 years old, and had an average of 12.9 years of education. The Virtual Reality Functional Capacity Assessment Tool (VRFCAT) was the computer-based measure of functional capacity. We used the MATRICS Consensus Cognitive Battery (MCCB) as an objective measure of neurocognition and the UCSD Performance-Based Skills Assessment (UPSA) to assess functional capacity performance. The Global Functioning Scale: Role and Social, and the Role Functioning Scale were used to assess work and school performance, familial interactions, and social functioning. Results We were able to confirm that the deficit in functional capacity performance measured using VRFCAT is present in the early course of schizophrenia in that the patients were slower and committed more errors (M=830.41) as compared with normal controls (M=716.84; t=3.0, p<.01). Virtual reality based assessment of functional capacity was correlated with objective measures of neurocognition (MCCB Overall Composite), r=-.71, p=<.01, standard approaches to functional capacity assessment (UPSA), r=-.66, p=<.01, work and school functioning (r=-.52, p<.01), and level of social relationships (r=-.43, p=<.03), but not familial relationships (r=-.03, p=.87). Interestingly, neither neurocognition (MCCB) nor functional capacity performance (UPSA) were correlated with the level of familial relationships. Discussion We extend previous findings in that even patients in the early course of schizophrenia showed virtual reality based functional capacity performance deficits when compared with normal control subjects. Virtual reality based performance was correlated with neurocognition, suggesting that it may be sensitive to changes in cognition. Furthermore, correlations with everyday work/school and social functioning indicate promise as a co-primary measure to index change in functioning in response to treatment. Interestingly, none of our measures of functional capacity or neurocognition were correlated with familial relationships indicating that the determinates of family interactions might be driven by factors other than cognitive capacities.

  11. THE STATISTICAL ANALYSIS OF DISCRETE AND CONTINUOUS OUTCOMES USING DESIRABILITY FUNCTIONS.

    EPA Science Inventory

    Multiple types of outcomes are sometimes measured on each animal in toxicology dose-response experiments. In this paper we introduce a method of deriving a composite score for a dose-response experiment that combines information from discrete and continuous outcomes through the ...

  12. Test-Anchored Vibration Response Predictions for an Acoustically Energized Curved Orthogrid Panel with Mounted Components

    NASA Technical Reports Server (NTRS)

    Frady, Gregory P.; Duvall, Lowery D.; Fulcher, Clay W. G.; Laverde, Bruce T.; Hunt, Ronald A.

    2011-01-01

    rich body of vibroacoustic test data was recently generated at Marshall Space Flight Center for component-loaded curved orthogrid panels typical of launch vehicle skin structures. The test data were used to anchor computational predictions of a variety of spatially distributed responses including acceleration, strain and component interface force. Transfer functions relating the responses to the input pressure field were generated from finite element based modal solutions and test-derived damping estimates. A diffuse acoustic field model was applied to correlate the measured input sound pressures across the energized panel. This application quantifies the ability to quickly and accurately predict a variety of responses to acoustically energized skin panels with mounted components. Favorable comparisons between the measured and predicted responses were established. The validated models were used to examine vibration response sensitivities to relevant modeling parameters such as pressure patch density, mesh density, weight of the mounted component and model form. Convergence metrics include spectral densities and cumulative root-mean squared (RMS) functions for acceleration, velocity, displacement, strain and interface force. Minimum frequencies for response convergence were established as well as recommendations for modeling techniques, particularly in the early stages of a component design when accurate structural vibration requirements are needed relatively quickly. The results were compared with long-established guidelines for modeling accuracy of component-loaded panels. A theoretical basis for the Response/Pressure Transfer Function (RPTF) approach provides insight into trends observed in the response predictions and confirmed in the test data. The software developed for the RPTF method allows easy replacement of the diffuse acoustic field with other pressure fields such as a turbulent boundary layer (TBL) model suitable for vehicle ascent. Structural responses using a TBL model were demonstrated, and wind tunnel tests have been proposed to anchor the predictions and provide new insight into modeling approaches for this environment. Finally, design load factors were developed from the measured and predicted responses and compared with those derived from traditional techniques such as historical Mass Acceleration Curves and Barrett scaling methods for acreage and component-loaded panels.

  13. P2Y12 expression and function in alternatively activated human microglia

    PubMed Central

    Ase, Ariel R.; Kinsara, Angham; Rao, Vijayaraghava T.S.; Michell-Robinson, Mackenzie; Leong, Soo Yuen; Butovsky, Oleg; Ludwin, Samuel K.; Séguéla, Philippe; Bar-Or, Amit; Antel, Jack P.

    2015-01-01

    Objective: To investigate and measure the functional significance of altered P2Y12 expression in the context of human microglia activation. Methods: We performed in vitro and in situ experiments to measure how P2Y12 expression can influence disease-relevant functional properties of classically activated (M1) and alternatively activated (M2) human microglia in the inflamed brain. Results: We demonstrated that compared to resting and classically activated (M1) human microglia, P2Y12 expression is increased under alternatively activated (M2) conditions. In response to ADP, the endogenous ligand of P2Y12, M2 microglia have increased ligand-mediated calcium responses, which are blocked by selective P2Y12 antagonism. P2Y12 antagonism was also shown to decrease migratory and inflammatory responses in human microglia upon exposure to nucleotides that are released during CNS injury; no effects were observed in human monocytes or macrophages. In situ experiments confirm that P2Y12 is selectively expressed on human microglia and elevated under neuropathologic conditions that promote Th2 responses, such as parasitic CNS infection. Conclusion: These findings provide insight into the roles of M2 microglia in the context of neuroinflammation and suggest a mechanism to selectively target a functionally unique population of myeloid cells in the CNS. PMID:25821842

  14. Assessment of Murine Retinal Function by Electroretinography

    PubMed Central

    Benchorin, Gillie; Calton, Melissa A.; Beaulieu, Marielle O.; Vollrath, Douglas

    2017-01-01

    The electroretinogram (ERG) is a sensitive and noninvasive method for testing retinal function. In this protocol, we describe a method for performing ERGs in mice. Contact lenses on the mouse cornea measure the electrical response to a light stimulus of photoreceptors and downstream retinal cells, and the collected data are analyzed to evaluate retinal function. PMID:29177186

  15. Method and apparatus for sensing a target characteristic by measuring both impedance and resonant frequency of a tank circuit

    NASA Technical Reports Server (NTRS)

    Laskowski, Edward L. (Inventor)

    1995-01-01

    An apparatus for sensing a target characteristic, such as relative distance between the apparatus and target, target thickness, target material, or lateral position between the apparatus and the target, includes a coil for directing an electro-magnetic field at the target. A voltage controlled oscillator energizes the coil at a resonant frequency which is functionally related to the target characteristic. The coil has an effective impedance value at resonance functionally related to the target characteristic. A frequency monitor measures the resonant frequency. An impedance monitor determines the impedance value when the drive frequency is at the resonant value. A PROM or controller determines the target characteristic in response to the measured resonant frequency and the determined impedance value. The PROM or controller provides a signal responsive to the determined target characteristic.

  16. Signal pulse emulation for scintillation detectors using Geant4 Monte Carlo with light tracking simulation.

    PubMed

    Ogawara, R; Ishikawa, M

    2016-07-01

    The anode pulse of a photomultiplier tube (PMT) coupled with a scintillator is used for pulse shape discrimination (PSD) analysis. We have developed a novel emulation technique for the PMT anode pulse based on optical photon transport and a PMT response function. The photon transport was calculated using Geant4 Monte Carlo code and the response function with a BC408 organic scintillator. The obtained percentage RMS value of the difference between the measured and simulated pulse with suitable scintillation properties using GSO:Ce (0.4, 1.0, 1.5 mol%), LaBr3:Ce and BGO scintillators were 2.41%, 2.58%, 2.16%, 2.01%, and 3.32%, respectively. The proposed technique demonstrates high reproducibility of the measured pulse and can be applied to simulation studies of various radiation measurements.

  17. Defining and quantifying the resilience of responses to disturbance: a conceptual and modelling approach from soil science

    PubMed Central

    Todman, L. C.; Fraser, F. C.; Corstanje, R.; Deeks, L. K.; Harris, J. A.; Pawlett, M.; Ritz, K.; Whitmore, A. P.

    2016-01-01

    There are several conceptual definitions of resilience pertaining to environmental systems and, even if resilience is clearly defined in a particular context, it is challenging to quantify. We identify four characteristics of the response of a system function to disturbance that relate to “resilience”: (1) degree of return of the function to a reference level; (2) time taken to reach a new quasi-stable state; (3) rate (i.e. gradient) at which the function reaches the new state; (4) cumulative magnitude of the function (i.e. area under the curve) before a new state is reached. We develop metrics to quantify these characteristics based on an analogy with a mechanical spring and damper system. Using the example of the response of a soil function (respiration) to disturbance, we demonstrate that these metrics effectively discriminate key features of the dynamic response. Although any one of these characteristics could define resilience, each may lead to different insights and conclusions. The salient properties of a resilient response must thus be identified for different contexts. Because the temporal resolution of data affects the accurate determination of these metrics, we recommend that at least twelve measurements are made over the temporal range for which the response is expected. PMID:27329053

  18. Plant hydraulic diversity buffers forest ecosystem responses to drought

    NASA Astrophysics Data System (ADS)

    Anderegg, W.; Konings, A. G.; Trugman, A. T.; Pacala, S. W.; Yu, K.; Sulman, B. N.; Sperry, J.; Bowling, D. R.

    2017-12-01

    Drought impacts carbon, water, and energy cycles in forests and may pose a fundamental threat to forests in future climates. Plant hydraulic transport of water is central to tree drought responses, including curtailing of water loss and the risk of mortality during drought. The effect of biodiversity on ecosystem function has typically been examined in grasslands, yet the diversity of plant hydraulic strategies may influence forests' response to drought. In a combined analysis of eddy covariance measurements, remote-sensing data of plant water content variation, model simulations, and plant hydraulic trait data, we test the degree to which plant water stress schemes influence the carbon cycle and how hydraulic diversity within and across ecosystems affects large-scale drought responses. We find that current plant functional types are not well-suited to capture hydraulic variation and that higher hydraulic diversity buffers ecosystem variation during drought. Our results demonstrate that tree functional diversity, particularly hydraulic diversity, may be critical to simulate in plant functional types in current land surface model projections of future vegetation's response to climate extremes.

  19. Differential item functioning analysis of the Vanderbilt Expertise Test for cars

    PubMed Central

    Lee, Woo-Yeol; Cho, Sun-Joo; McGugin, Rankin W.; Van Gulick, Ana Beth; Gauthier, Isabel

    2015-01-01

    The Vanderbilt Expertise Test for cars (VETcar) is a test of visual learning for contemporary car models. We used item response theory to assess the VETcar and in particular used differential item functioning (DIF) analysis to ask if the test functions the same way in laboratory versus online settings and for different groups based on age and gender. An exploratory factor analysis found evidence of multidimensionality in the VETcar, although a single dimension was deemed sufficient to capture the recognition ability measured by the test. We selected a unidimensional three-parameter logistic item response model to examine item characteristics and subject abilities. The VETcar had satisfactory internal consistency. A substantial number of items showed DIF at a medium effect size for test setting and for age group, whereas gender DIF was negligible. Because online subjects were on average older than those tested in the lab, we focused on the age groups to conduct a multigroup item response theory analysis. This revealed that most items on the test favored the younger group. DIF could be more the rule than the exception when measuring performance with familiar object categories, therefore posing a challenge for the measurement of either domain-general visual abilities or category-specific knowledge. PMID:26418499

  20. Reproducibility and repeatability of peripheral microvascular assessment using iontophoresis in conjunction with laser Doppler imaging.

    PubMed

    Jadhav, Sachin; Sattar, Naveed; Petrie, John R; Cobbe, Stuart M; Ferrell, William R

    2007-09-01

    Interrogation of peripheral vascular function is increasingly recognized as a noninvasive surrogate marker for coronary vascular function and carries with it important prognostic information regarding future cardiovascular risk. Laser Doppler imaging (LDI) is a completely noninvasive method for looking at peripheral microvascular function. We sought to look at reproducibility and repeatability of LDI-derived assessment of peripheral microvascular function between arms and 8 weeks apart. We used LDI in conjunction with iontophoretic application of ACh and SNP to look at endothelium-dependent and -independent microvascular function, respectively, in a mixture of women with cardiac syndrome X and healthy volunteers. We looked at variation between arms (n = 40) and variation at 8 weeks apart (n = 22). When measurements were corrected for skin resistance, there was nonsignificant variation between arms for ACh (2.7%) and SNP (3.8%) and nonsignificant temporal variation for ACh (3.5%) and SNP (4.7%). Construction of Bland-Altman plots reinforce that measurements have good repeatability. Elimination of the baseline perfusion response had deleterious effects on repeatability. LDI can be used to assess peripheral vascular response with good repeatability as long as measurements are corrected for skin resistance, which affects drug delivery. This has important implications for the future use of LDI.

  1. Functional imaging of the human brain using a modular, fibre-less, high-density diffuse optical tomography system.

    PubMed

    Chitnis, Danial; Cooper, Robert J; Dempsey, Laura; Powell, Samuel; Quaggia, Simone; Highton, David; Elwell, Clare; Hebden, Jeremy C; Everdell, Nicholas L

    2016-10-01

    We present the first three-dimensional, functional images of the human brain to be obtained using a fibre-less, high-density diffuse optical tomography system. Our technology consists of independent, miniaturized, silicone-encapsulated DOT modules that can be placed directly on the scalp. Four of these modules were arranged to provide up to 128, dual-wavelength measurement channels over a scalp area of approximately 60 × 65 mm 2 . Using a series of motor-cortex stimulation experiments, we demonstrate that this system can obtain high-quality, continuous-wave measurements at source-detector separations ranging from 14 to 55 mm in adults, in the presence of hair. We identify robust haemodynamic response functions in 5 out of 5 subjects, and present diffuse optical tomography images that depict functional haemodynamic responses that are well-localized in all three dimensions at both the individual and group levels. This prototype modular system paves the way for a new generation of wearable, wireless, high-density optical neuroimaging technologies.

  2. Numerical integration of detector response functions via Monte Carlo simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly, Keegan John; O'Donnell, John M.; Gomez, Jaime A.

    Calculations of detector response functions are complicated because they include the intricacies of signal creation from the detector itself as well as a complex interplay between the detector, the particle-emitting target, and the entire experimental environment. As such, these functions are typically only accessible through time-consuming Monte Carlo simulations. Furthermore, the output of thousands of Monte Carlo simulations can be necessary in order to extract a physics result from a single experiment. Here we describe a method to obtain a full description of the detector response function using Monte Carlo simulations. We also show that a response function calculated inmore » this way can be used to create Monte Carlo simulation output spectra a factor of ~1000× faster than running a new Monte Carlo simulation. A detailed discussion of the proper treatment of uncertainties when using this and other similar methods is provided as well. Here, this method is demonstrated and tested using simulated data from the Chi-Nu experiment, which measures prompt fission neutron spectra at the Los Alamos Neutron Science Center.« less

  3. Numerical integration of detector response functions via Monte Carlo simulations

    NASA Astrophysics Data System (ADS)

    Kelly, K. J.; O'Donnell, J. M.; Gomez, J. A.; Taddeucci, T. N.; Devlin, M.; Haight, R. C.; White, M. C.; Mosby, S. M.; Neudecker, D.; Buckner, M. Q.; Wu, C. Y.; Lee, H. Y.

    2017-09-01

    Calculations of detector response functions are complicated because they include the intricacies of signal creation from the detector itself as well as a complex interplay between the detector, the particle-emitting target, and the entire experimental environment. As such, these functions are typically only accessible through time-consuming Monte Carlo simulations. Furthermore, the output of thousands of Monte Carlo simulations can be necessary in order to extract a physics result from a single experiment. Here we describe a method to obtain a full description of the detector response function using Monte Carlo simulations. We also show that a response function calculated in this way can be used to create Monte Carlo simulation output spectra a factor of ∼ 1000 × faster than running a new Monte Carlo simulation. A detailed discussion of the proper treatment of uncertainties when using this and other similar methods is provided as well. This method is demonstrated and tested using simulated data from the Chi-Nu experiment, which measures prompt fission neutron spectra at the Los Alamos Neutron Science Center.

  4. Numerical integration of detector response functions via Monte Carlo simulations

    DOE PAGES

    Kelly, Keegan John; O'Donnell, John M.; Gomez, Jaime A.; ...

    2017-06-13

    Calculations of detector response functions are complicated because they include the intricacies of signal creation from the detector itself as well as a complex interplay between the detector, the particle-emitting target, and the entire experimental environment. As such, these functions are typically only accessible through time-consuming Monte Carlo simulations. Furthermore, the output of thousands of Monte Carlo simulations can be necessary in order to extract a physics result from a single experiment. Here we describe a method to obtain a full description of the detector response function using Monte Carlo simulations. We also show that a response function calculated inmore » this way can be used to create Monte Carlo simulation output spectra a factor of ~1000× faster than running a new Monte Carlo simulation. A detailed discussion of the proper treatment of uncertainties when using this and other similar methods is provided as well. Here, this method is demonstrated and tested using simulated data from the Chi-Nu experiment, which measures prompt fission neutron spectra at the Los Alamos Neutron Science Center.« less

  5. Initial Sensorimotor and Cardiovascular Data Acquired from Soyuz Landings: Establishing a Functional Performance Recovery Time Constant

    NASA Technical Reports Server (NTRS)

    Reschke, M. F.; Kozlovskaya, I. B.; Kofman, I. S.; Tomilovskaya, E. S.; Cerisano, J. M.; Bloomberg, J. J.; Stenger, M. B.; Platts, S. H.; Rukavishnikov, I. V.; Fomina, E. V.; hide

    2015-01-01

    INTRODUCTION Testing of crew responses following long-duration flights has not been previously possible until a minimum of more than 24 hours after landing. As a result, it has not been possible to determine the trend of the early recovery process, nor has it been possible to accurately assess the full impact of the decrements associated with long-duration flight. To overcome these limitations, both the Russian and U.S. programs have implemented joint testing at the Soyuz landing site. This International Space Station research effort has been identified as the functional Field Test, and represents data collect on NASA, Russian, European Space Agency, and Japanese Aerospace Exploration Agency crews. RESEARCH The primary goal of this research is to determine functional abilities associated with long-duration space flight crews beginning as soon after landing as possible on the day of landing (typically within 1 to 1.5 hours). This goal has both sensorimotor and cardiovascular elements. To date, a total of 15 subjects have participated in a 'pilot' version of the full 'field test'. The full version of the 'field test' will assess functional sensorimotor measurements included hand/eye coordination, standing from a seated position (sit-to-stand), walking normally without falling, measurement of dynamic visual acuity, discriminating different forces generated with the hands (both strength and ability to judge just noticeable differences of force), standing from a prone position, coordinated walking involving tandem heel-to-toe placement (tested with eyes both closed and open), walking normally while avoiding obstacles of differing heights, and determining postural ataxia while standing (measurement of quiet stance). Sensorimotor performance has been obtained using video records, and data from body worn inertial sensors. The cardiovascular portion of the investigation has measured blood pressure and heart rate during a timed stand test in conjunction with postural ataxia testing (quiet stance sway) as well as cardiovascular responses during sensorimotor testing on all of the above measures. We have also collected motion sickness data associated with each of the postflight tests. When possible rudimentary cerebellar assessment was undertaken. In addition to the immediate post-landing collection of data, postflight data has been acquired twice more within 24 hours after landing and measurements continue until sensorimotor and cardiovascular responses have returned to preflight normative values (approximately 60 days postflight). SUMMARY The level of functional deficit observed in the crew tested to date is more severe than expected, clearly triggered by the acquisition of gravity loads immediately after landing when the demands for crew intervention in response to emergency operations will be greatest. Measureable performance parameters such as ability to perform a seat egress, recover from a fall or the ability to see clearly when walking, and related physiologic data (orthostatic responses) are required to provide an evidence base for characterizing programmatic risks and the degree of variability among crewmembers for exploration missions where the crew will be unassisted after landing. Overall, these early functional and related physiologic measurements will allow the estimation of nonlinear sensorimotor and cardiovascular recovery trends that have not been previously captured.

  6. The relationship of systemic markers of renal function and vascular function with retinal blood vessel responses.

    PubMed

    Heitmar, R; Varma, C; De, P; Lau, Y C; Blann, A D

    2016-11-01

    To test the hypothesis of a significant relationship between systemic markers of renal and vascular function (processes linked to cardiovascular disease and its development) and retinal microvascular function in diabetes and/or cardiovascular disease. Ocular microcirculatory function was measured in 116 patients with diabetes and/or cardiovascular disease using static and continuous retinal vessel responses to three cycles of flickering light. Endothelial function was evaluated by von Willebrand factor (vWf), endothelial microparticles and soluble E selectin, renal function by serum creatinine, creatinine clearance and estimated glomerular filtration rate (eGFR). HbA1c was used as a control index. Central retinal vein equivalence and venous maximum dilation to flicker were linked to HbA1c (both p < 0.05). Arterial reaction time was linked to serum creatinine (p = 0.036) and eGFR (p = 0.039); venous reaction time was linked to creatinine clearance (p = 0.018). Creatinine clearance and eGFR were linked to arterial maximum dilatation (p < 0.001 and p = 0.003, respectively) and the dilatation amplitude (p = 0.038 and p = 0.048, respectively) responses in the third flicker cycle. Of venous responses to the first flicker cycle, HbA1c was linked to the maximum dilation response (p = 0.004) and dilatation amplitude (p = 0.017), vWf was linked to the maximum constriction response (p = 0.016), and creatinine clearance to the baseline diameter fluctuation (p = 0.029). In the second flicker cycle, dilatation amplitude was linked to serum creatinine (p = 0.022). Several retinal blood vessel responses to flickering light are linked to glycaemia and renal function, but only one index is linked to endothelial function. Renal function must be considered when interpreting retinal vessel responses.

  7. Do Right- and Left-Handed Monkeys Differ on Cognitive Measures?

    NASA Technical Reports Server (NTRS)

    Hopkins, William D.; Washburn, David A.

    1994-01-01

    Twelve left- and 14 right-handed monkeys were compared on 6 measures of cognitive performance (2 maze-solving tasks, matching-to-sample, delayed matching-to-sample, delayed response using spatial cues, and delayed response using form cues). The dependent variable was trials-to-training criterion for each of the 6 tasks. Significant differences were found between left- and right-handed monkeys on the 2 versions of the delayed response task. Right-handed monkeys reached criterion significantly faster on the form cue version of the task, whereas left-handed monkeys reached criterion significantly faster on delayed response for spatial position (p less than .05). The results suggest that sensitive hand preference measures of laterality can reveal differences in cognitive performance, which in turn may reflect underlying laterality in functional organization of the nervous system.

  8. Secondary Psychometric Examination of the Dimensional Obsessive-Compulsive Scale: Classical Testing, Item Response Theory, and Differential Item Functioning.

    PubMed

    Thibodeau, Michel A; Leonard, Rachel C; Abramowitz, Jonathan S; Riemann, Bradley C

    2015-12-01

    The Dimensional Obsessive-Compulsive Scale (DOCS) is a promising measure of obsessive-compulsive disorder (OCD) symptoms but has received minimal psychometric attention. We evaluated the utility and reliability of DOCS scores. The study included 832 students and 300 patients with OCD. Confirmatory factor analysis supported the originally proposed four-factor structure. DOCS total and subscale scores exhibited good to excellent internal consistency in both samples (α = .82 to α = .96). Patient DOCS total scores reduced substantially during treatment (t = 16.01, d = 1.02). DOCS total scores discriminated between students and patients (sensitivity = 0.76, 1 - specificity = 0.23). The measure did not exhibit gender-based differential item functioning as tested by Mantel-Haenszel chi-square tests. Expected response options for each item were plotted as a function of item response theory and demonstrated that DOCS scores incrementally discriminate OCD symptoms ranging from low to extremely high severity. Incremental differences in DOCS scores appear to represent unbiased and reliable differences in true OCD symptom severity. © The Author(s) 2014.

  9. Item response theory analyses of the Delis-Kaplan Executive Function System card sorting subtest.

    PubMed

    Spencer, Mercedes; Cho, Sun-Joo; Cutting, Laurie E

    2018-02-02

    In the current study, we examined the dimensionality of the 16-item Card Sorting subtest of the Delis-Kaplan Executive Functioning System assessment in a sample of 264 native English-speaking children between the ages of 9 and 15 years. We also tested for measurement invariance for these items across age and gender groups using item response theory (IRT). Results of the exploratory factor analysis indicated that a two-factor model that distinguished between verbal and perceptual items provided the best fit to the data. Although the items demonstrated measurement invariance across age groups, measurement invariance was violated for gender groups, with two items demonstrating differential item functioning for males and females. Multigroup analysis using all 16 items indicated that the items were more effective for individuals whose IRT scale scores were relatively high. A single-group explanatory IRT model using 14 non-differential item functioning items showed that for perceptual ability, females scored higher than males and that scores increased with age for both males and females; for verbal ability, the observed increase in scores across age differed for males and females. The implications of these findings are discussed.

  10. The Nursing Home Physical Performance Test: A Secondary Data Analysis of Women in Long-Term Care Using Item Response Theory.

    PubMed

    Perera, Subashan; Nace, David A; Resnick, Neil M; Greenspan, Susan L

    2017-04-11

    The Nursing Home Physical Performance Test (NHPPT) was developed to measure function among nursing home residents using sit-to-stand, scooping applesauce, face washing, dialing phone, putting on sweater, and ambulating tasks. Using item response theory, we explore its measurement characteristics at item level and opportunities for improvements. We used data from long-term care women. We fitted a graded response model, estimated parameters, and constructed probability and information curves. We identified items to be targeted toward lower and higher functioning persons to increase the range of abilities to which the instrument is applicable. We revised the scoring by making sit-to-stand and sweater items harder and dialing phone easier. We examined changes to concurrent validity with activities of daily living (ADL), frailty, and cognitive function. Participants were 86 years old, had more than three comorbidities, and a NHPPT of 19.4. All items had high discrimination and were targeted toward the lower middle range of performance continuum. After revision, sit-to-stand and sweater items demonstrated greater discrimination among the higher functioning and/or greater spread of thresholds for response categories. The overall test showed discrimination over a wider range of individuals. Concurrent validity correlation improved from 0.60 to 0.68 for instrumental ADL and explained variability (R2) from 22% to 36% for frailty. NHPPT has good measurement characteristics at the item level. NHPPT can be improved, implemented in computerized adaptive testing, and combined with self-report for greater utility, but a definitive study is needed. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. Analysis of the operation of the SCD Response intermittent compression system.

    PubMed

    Morris, Rh J; Griffiths, H; Woodcock, J P

    2002-01-01

    The work assessed the performance of the Kendall SCD Response intermittent pneumatic compression system for deep vein thrombosis prophylaxis, which claimed to set its cycle according to the blood flow characteristics of individual patient limbs. A series of tests measured the system response in various situations, including application to the limbs of healthy volunteers, and to false limbs. Practical experimentation and theoretical analysis were used to investigate influences on the system functioning other than blood flow. The system tested did not seem to perform as claimed, being unable to distinguish between real and fake limbs. The intervals between compressions were set to times unrealistic for venous refill, with temperature changes in the cuff the greatest influence on performance. Combining the functions of compression and the measurement of the effects of compression in the same air bladder makes temperature artefacts unavoidable and can cause significant errors in the inter-compression interval.

  12. Do romantic partners' responses to entry dyspareunia affect women's experience of pain? The roles of catastrophizing and self-efficacy.

    PubMed

    Lemieux, Ashley J; Bergeron, Sophie; Steben, Marc; Lambert, Bernard

    2013-09-01

    Entry dyspareunia is a sexual health concern which affects about 21% of women in the general population. Characterized by pain provoked during vaginal penetration, introital dyspareunia has been shown by controlled studies to have a negative impact on the psychological well-being, sexual function, sexual satisfaction, and quality of life of afflicted women. Many cognitive and affective variables may influence the experience of pain and associated psychosexual problems. However, the role of the partner's cognitive responses has been studied very little. The aim of the present study was to examine the associations between partners' catastrophizing and their perceptions of women's self-efficacy at managing pain on one side and women's pain intensity, sexual function, and sexual satisfaction on the other. One hundred seventy-nine heterosexual couples (mean age for women = 31, SD = 10.0; mean age for men = 33, SD = 10.6) in which the woman suffered from entry dyspareunia participated in the study. Both partners completed quantitative measures. Women completed the Pain Catastrophizing Scale and the Painful Intercourse Self-Efficacy Scale. Men completed the significant-other versions of these measures. Dependent measures were women's responses to (i) the Pain Numeric Visual Analog Scale; (ii) the Female Sexual Function Index; and (iii) the Global Measure of Sexual Satisfaction scale. Controlled for women's pain catastrophizing and self-efficacy, results indicate that higher levels of partner-perceived self-efficacy and lower levels of partner catastrophizing are associated with decreased pain intensity in women with entry dyspareunia, although only partner catastrophizing contributed unique variance. Partner-perceived self-efficacy and catastrophizing were not significantly associated with sexual function or satisfaction in women. The findings suggest that partners' cognitive responses may influence the experience of entry dyspareunia for women, pointing toward the importance of considering the partner when treating this sexual health problem. © 2013 International Society for Sexual Medicine.

  13. The effects of state and trait self-focused attention on sexual arousal in sexually functional and dysfunctional women

    PubMed Central

    Meston, Cindy M.

    2010-01-01

    This study examined the effects of state self-focused attention on sexual arousal and trait self-consciousness on sexual arousal and function in sexually functional (n = 16) and dysfunctional (n = 16) women. Self-focused attention was induced using a 50% reflectant television screen in one of two counterbalanced sessions during which self-report and physiological sexual responses to erotic films were measured. Self-focused attention significantly decreased vaginal pulse amplitude (VPA) responses among sexually functional but not dysfunctional women, and substantially decreased correlations between self-report and VPA measures of sexual arousal. Self-focused attention did not significantly impact subjective sexual arousal in sexually functional or dysfunctional women. Trait private self-consciousness was positively related to sexual desire, orgasm, compatibility, contentment and sexual satisfaction. Public self-consciousness was correlated with sexual pain. The findings are discussed in terms of Masters and Johnson’s [Masters, W. H. & Johnson, V. E. (1970). Human sexual inadequacy. Boston: Little, Brown) concepts of “spectatoring” and “sensate focus.” PMID:15927143

  14. Influence of Acute Multispecies and Multistrain Probiotic Supplementation on Cardiovascular Function and Reactivity to Psychological Stress in Young Adults: A Double-Blind, Randomized, Placebo-Controlled Trial.

    PubMed

    Möller, Clara M; Olsa, Eamon J A; Ginty, Annie T; Rapelje, Alyssa L; Tindall, Christina L; Holesh, Laura A; Petersen, Karen L; Conklin, Sarah M

    2017-10-01

    The potential influence of probiotic supplementation on cardiovascular health and stress responsivity remains largely unexplored. Some evidence suggests the possibility that probiotics may influence blood pressure. A separate body of research suggests that exaggerated cardiovascular reactions to acute psychological stress in the laboratory predict cardiovascular morbidity and mortality. The current investigation explored the effect of acute probiotic use on (1) resting cardiovascular measures in healthy young adults and (2) cardiovascular and psychological reactions to an acute psychological stressor in the laboratory. Participants (N = 105, M [SD] age = 20.17 [1.26], 84.8% white) completed a 2-week, double-blind, and placebo-controlled trial of a multispecies and multistrain probiotic. Exclusion criteria included previous probiotic use, diagnosed gastrointestinal disorder, and/or current antibiotic use. At visits 1 and 2, participants completed the Paced Auditory Serial Addition Test, a widely used psychological stress task. Participants were randomly assigned to a probiotic blend or matched placebo. Compared with placebo, 2-week probiotic supplementation did not affect resting measures of cardiovascular function, cardiovascular responses during or recovery from stress, or psychological reactions to acute psychological stress. Contrary to expectations, short-term use of a probiotic supplement in healthy participants did not influence measures of cardiovascular function or responsivity to psychological stress. Future research is needed to determine species- and strain-specific effects of probiotics in healthy participants with various degrees of stress responsiveness, as well as in diseased populations.

  15. A fractional-order accumulative regularization filter for force reconstruction

    NASA Astrophysics Data System (ADS)

    Wensong, Jiang; Zhongyu, Wang; Jing, Lv

    2018-02-01

    The ill-posed inverse problem of the force reconstruction comes from the influence of noise to measured responses and results in an inaccurate or non-unique solution. To overcome this ill-posedness, in this paper, the transfer function of the reconstruction model is redefined by a Fractional order Accumulative Regularization Filter (FARF). First, the measured responses with noise are refined by a fractional-order accumulation filter based on a dynamic data refresh strategy. Second, a transfer function, generated by the filtering results of the measured responses, is manipulated by an iterative Tikhonov regularization with a serious of iterative Landweber filter factors. Third, the regularization parameter is optimized by the Generalized Cross-Validation (GCV) to improve the ill-posedness of the force reconstruction model. A Dynamic Force Measurement System (DFMS) for the force reconstruction is designed to illustrate the application advantages of our suggested FARF method. The experimental result shows that the FARF method with r = 0.1 and α = 20, has a PRE of 0.36% and an RE of 2.45%, is superior to other cases of the FARF method and the traditional regularization methods when it comes to the dynamic force reconstruction.

  16. Contrast Responsivity in MT+ Correlates with Phonological Awareness and Reading Measures in Children

    PubMed Central

    Ben-Shachar, Michal; Dougherty, Robert F.; Deutsch, Gayle K.; Wandell, Brian A.

    2007-01-01

    There are several independent sets of findings concerning the neural basis of reading. One set demonstrates a powerful relationship between phonological processing and reading skills. Another set reveals a relationship between visual responses in the motion pathways and reading skills. It is widely assumed that these two findings are unrelated. We tested the hypothesis that phonological awareness is related to motion responsivity in children’s MT+. We measured BOLD signals to drifting gratings as a function of contrast. Subjects were 35 children ages 7–12y with a wide range of reading skills. Contrast responsivity in MT+, but not V1, was correlated with phonological awareness and to a lesser extent with two other measures of reading. No correlation was found between MT+ signals and rapid naming, age or general IQ measures. These results establish an important link between visual and phonological processing in children and suggest that MT+ responsivity is a marker for healthy reading development. PMID:17689981

  17. Monaural and binaural contributions to interaural-level-difference sensitivity in human auditory cortex.

    PubMed

    Stecker, G Christopher; McLaughlin, Susan A; Higgins, Nathan C

    2015-10-15

    Whole-brain functional magnetic resonance imaging was used to measure blood-oxygenation-level-dependent (BOLD) responses in human auditory cortex (AC) to sounds with intensity varying independently in the left and right ears. Echoplanar images were acquired at 3 Tesla with sparse image acquisition once per 12-second block of sound stimulation. Combinations of binaural intensity and stimulus presentation rate were varied between blocks, and selected to allow measurement of response-intensity functions in three configurations: monaural 55-85 dB SPL, binaural 55-85 dB SPL with intensity equal in both ears, and binaural with average binaural level of 70 dB SPL and interaural level differences (ILD) ranging ±30 dB (i.e., favoring the left or right ear). Comparison of response functions equated for contralateral intensity revealed that BOLD-response magnitudes (1) generally increased with contralateral intensity, consistent with positive drive of the BOLD response by the contralateral ear, (2) were larger for contralateral monaural stimulation than for binaural stimulation, consistent with negative effects (e.g., inhibition) of ipsilateral input, which were strongest in the left hemisphere, and (3) also increased with ipsilateral intensity when contralateral input was weak, consistent with additional, positive, effects of ipsilateral stimulation. Hemispheric asymmetries in the spatial extent and overall magnitude of BOLD responses were generally consistent with previous studies demonstrating greater bilaterality of responses in the right hemisphere and stricter contralaterality in the left hemisphere. Finally, comparison of responses to fast (40/s) and slow (5/s) stimulus presentation rates revealed significant rate-dependent adaptation of the BOLD response that varied across ILD values. Copyright © 2015. Published by Elsevier Inc.

  18. Catecholamine responses to virtual combat: implications for post-traumatic stress and dimensions of functioning.

    PubMed

    Highland, Krista B; Costanzo, Michelle E; Jovanovic, Tanja; Norrholm, Seth D; Ndiongue, Rochelle B; Reinhardt, Brian J; Rothbaum, Barbara; Rizzo, Albert A; Roy, Michael J

    2015-01-01

    Posttraumatic stress disorder (PTSD) symptoms can result in functional impairment among service members (SMs), even in those without a clinical diagnosis. The variability in outcomes may be related to underlying catecholamine mechanisms. Individuals with PTSD tend to have elevated basal catecholamine levels, though less is known regarding catecholamine responses to trauma-related stimuli. We assessed whether catecholamine responses to a virtual combat environment impact the relationship between PTSD symptom clusters and elements of functioning. Eighty-seven clinically healthy SMs, within 2 months after deployment to Iraq or Afghanistan, completed self-report measures, viewed virtual-reality (VR) combat sequences, and had sequential blood draws. Norepinephrine responses to VR combat exposure moderated the relationship between avoidance symptoms and scales of functioning including physical functioning, physical-role functioning, and vitality. Among those with high levels of avoidance, norepinephrine change was inversely associated with functional status, whereas a positive correlation was observed for those with low levels of avoidance. Our findings represent a novel use of a virtual environment to display combat-related stimuli to returning SMs to elucidate mind-body connections inherent in their responses. The insight gained improves our understanding of post-deployment symptoms and quality of life in SMs and may facilitate enhancements in treatment. Further research is needed to validate these findings in other populations and to define the implications for treatment effectiveness.

  19. Comparing the lower limb tasks questionnaire to the Western Ontario and McMaster Universities Osteoarthritis Index: agreement, responsiveness, and convergence with physical performance for knee osteoarthritis patients.

    PubMed

    McKay, Carly; Prapavessis, Harry; McNair, Peter

    2013-03-01

    To compare the Lower Limb Tasks Questionnaire (LLTQ) with the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) in terms of agreement, responsiveness, and convergence. Cross-sectional with an exploratory repeated-measures subsample analysis. Community-based seniors' centers and arthritis clinics. Individuals with symptomatic knee osteoarthritis (N=76) participated, with a subsample of 18 participants contributing to the pre- and postarthroplasty subanalysis. Not applicable. Bland and Altman plots of agreement with 95% limits of agreement, statistical responsiveness, and standardized response mean (SRM) were calculated for LLTQ and WOMAC subscales. Both t tests and Wilcoxon rank-sum tests were used to examine changes in pre- and postarthroplasty self-reported function, 50-ft walk speed, stair ascent/descent speed, and isometric quadriceps strength. The agreement (bias) of the LLTQ activities of daily living (ADL) subscale when compared with the WOMAC physical function (PF) subscale was 1%±10% (mean ± SD), and the 95% limits of agreement were -19% to +22%. The statistical responsiveness of the WOMAC-PF and LLTQ ADL was 1.17 and -.63, respectively. The SRMs for these scales were .90 and -.61, respectively. The WOMAC-PF scores showed a notable improvement over the first 6 weeks postarthroplasty, while LLTQ ADL scores were unchanged. The objective measures of function were all significantly worse at 6 weeks. The LLTQ demonstrated adequate agreement with the WOMAC and acceptable responsiveness for use in place of the WOMAC in nonspecialized clinics. The LLTQ may more accurately represent functional status after total knee arthroplasty, but further study in larger samples is recommended. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  20. Ginger Extract Suppresses Inflammatory Response and Maintains Barrier Function in Human Colonic Epithelial Caco-2 Cells Exposed to Inflammatory Mediators.

    PubMed

    Kim, Yunyoung; Kim, Dong-Min; Kim, Ji Yeon

    2017-05-01

    The beneficial effects of ginger in the management of gastrointestinal disturbances have been reported. In this study, the anti-inflammatory potential of ginger extract was assessed in a cellular model of gut inflammation. In addition, the effects of ginger extract and its major active compounds on intestinal barrier function were evaluated. The response of Caco-2 cells following exposure to a mixture of inflammatory mediators [interleukin [IL]-1β, 25 ng/mL; lipopolysaccharides [LPS], 10 ng/mL; tumor necrosis factor [TNF]-α, 50 ng/mL; and interferon [INF]-γ, 50 ng/mL] were assessed by measuring the levels of secreted IL-6 and IL-8. In addition, the mRNA levels of cyclooxygenase-2 and inducible nitric oxide synthase were measured. Moreover, the degree of nuclear factor (NF)-κB inhibition was examined, and the intestinal barrier function was determined by measuring the transepithelial electrical resistance (TEER) and fluorescein isothiocyanate (FITC)-dextran transfer. It was observed that ginger extract and its constituents improved inflammatory responses by decreasing the levels of nitrite, PGE2, IL-6, and IL-8 via NF-κB inhibition. The ginger extract also increased the TEER and decreased the transfer of FITC-dextran from the apical side of the epithelium to the basolateral side. Taken together, these results show that ginger extract may be developed as a functional food for the maintenance of gastrointestinal health. © 2017 Institute of Food Technologists®.

  1. Effect of type of cue, type of response, time delay and two different ongoing tasks on prospective memory functioning after acquired brain injury.

    PubMed

    Raskin, Sarah A; Buckheit, Carol A; Waxman, Amanda

    2012-01-01

    Failures of prospective memory (PM) are one of the most frequent, and least studied, sequelae of brain injury. PM, also referred to as memory for intentions, is the ability to remember to carry out a future task. Successful completion of a PM task requires the ability to monitor time, keep the action to be performed periodically in awareness, remember the task to be performed, and initiate the action. Although PM has been shown to be a common difficulty after brain injury, it remains unknown which aspects of performance are impaired. In this study, the performance of 25 individuals with brain injury and that of 25 healthy participants were measured separately on the following variables: time until completion of the task, difficulty of the ongoing task being performed while waiting, whether the task to be performed is an action or is verbal, and whether the cue to perform the task is the passing of a particular amount of time (e.g., 10 minutes) or is an external cue (e.g., an alarm sounding). Individuals with brain injury demonstrated impairment compared to healthy adults on virtually all variables. PM performance was also compared to a battery of standard neuropsychological measures of attention, memory, and executive functions, and to self-report measures of PM functioning, in order to determine the underlying cognitive deficits responsible for poor PM performance, if any. PM performance was correlated with measures of executive functioning but not to self-report measures of PM functioning. Implications are discussed in terms of cognitive rehabilitation recommendations.

  2. Functional linear models to test for differences in prairie wetland hydraulic gradients

    USGS Publications Warehouse

    Greenwood, Mark C.; Sojda, Richard S.; Preston, Todd M.; Swayne, David A.; Yang, Wanhong; Voinov, A.A.; Rizzoli, A.; Filatova, T.

    2010-01-01

    Functional data analysis provides a framework for analyzing multiple time series measured frequently in time, treating each series as a continuous function of time. Functional linear models are used to test for effects on hydraulic gradient functional responses collected from three types of land use in Northeastern Montana at fourteen locations. Penalized regression-splines are used to estimate the underlying continuous functions based on the discretely recorded (over time) gradient measurements. Permutation methods are used to assess the statistical significance of effects. A method for accommodating missing observations in each time series is described. Hydraulic gradients may be an initial and fundamental ecosystem process that responds to climate change. We suggest other potential uses of these methods for detecting evidence of climate change.

  3. Assessing the transferability of ecosystem service production estimates and functions

    EPA Science Inventory

    Estimates of ecosystem service (ES) production, and their responses to stressors or policy actions, may be obtained by direct measurement, other empirical studies, or modeling. Direct measurement is costly and often impractical, and thus many studies transfer ES production estim...

  4. Singular value description of a digital radiographic detector: Theory and measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kyprianou, Iacovos S.; Badano, Aldo; Gallas, Brandon D.

    The H operator represents the deterministic performance of any imaging system. For a linear, digital imaging system, this system operator can be written in terms of a matrix, H, that describes the deterministic response of the system to a set of point objects. A singular value decomposition of this matrix results in a set of orthogonal functions (singular vectors) that form the system basis. A linear combination of these vectors completely describes the transfer of objects through the linear system, where the respective singular values associated with each singular vector describe the magnitude with which that contribution to the objectmore » is transferred through the system. This paper is focused on the measurement, analysis, and interpretation of the H matrix for digital x-ray detectors. A key ingredient in the measurement of the H matrix is the detector response to a single x ray (or infinitestimal x-ray beam). The authors have developed a method to estimate the 2D detector shift-variant, asymmetric ray response function (RRF) from multiple measured line response functions (LRFs) using a modified edge technique. The RRF measurements cover a range of x-ray incident angles from 0 deg. (equivalent location at the detector center) to 30 deg. (equivalent location at the detector edge) for a standard radiographic or cone-beam CT geometric setup. To demonstrate the method, three beam qualities were tested using the inherent, Lu/Er, and Yb beam filtration. The authors show that measures using the LRF, derived from an edge measurement, underestimate the system's performance when compared with the H matrix derived using the RRF. Furthermore, the authors show that edge measurements must be performed at multiple directions in order to capture rotational asymmetries of the RRF. The authors interpret the results of the H matrix SVD and provide correlations with the familiar MTF methodology. Discussion is made about the benefits of the H matrix technique with regards to signal detection theory, and the characterization of shift-variant imaging systems.« less

  5. Distinguishing Adolescents With ADHD From Their Unaffected Siblings and Healthy Comparison Subjects by Neural Activation Patterns During Response Inhibition.

    PubMed

    van Rooij, Daan; Hoekstra, Pieter J; Mennes, Maarten; von Rhein, Daniel; Thissen, Andrieke J A M; Heslenfeld, Dirk; Zwiers, Marcel P; Faraone, Stephen V; Oosterlaan, Jaap; Franke, Barbara; Rommelse, Nanda; Buitelaar, Jan K; Hartman, Catharina A

    2015-07-01

    Dysfunctional response inhibition is a key executive function impairment in attention deficit hyperactivity disorder (ADHD). Still, behavioral response inhibition measures do not consistently differentiate affected from unaffected individuals. The authors therefore investigated neural correlates of response inhibition and the familial nature of these neural correlates. Functional MRI measurements of neural activation during the stop-signal task and behavioral measures of response inhibition were obtained in adolescents and young adults with ADHD (N=185), their unaffected siblings (N=111), and healthy comparison subjects (N=124). Stop-signal task reaction times were longer and error rates were higher in participants with ADHD, but not in their unaffected siblings, while reaction time variability was higher in both groups than in comparison subjects. Relative to comparison subjects, participants with ADHD and unaffected siblings had neural hypoactivation in frontal-striatal and frontal-parietal networks, whereby activation in inferior frontal and temporal/parietal nodes in unaffected siblings was intermediate between levels of participants with ADHD and comparison subjects. Furthermore, neural activation in inferior frontal nodes correlated with stop-signal reaction times, and activation in both inferior frontal and temporal/parietal nodes correlated with ADHD severity. Neural activation alterations in ADHD are more robust than behavioral response inhibition deficits and explain variance in response inhibition and ADHD severity. Although only affected participants with ADHD have deficient response inhibition, hypoactivation in inferior frontal and temporal-parietal nodes in unaffected siblings supports the familial nature of the underlying neural process. Activation deficits in these nodes may be useful as endophenotypes that extend beyond the affected individuals in the family.

  6. Optimisation of nano-silica modified self-compacting high-Volume fly ash mortar

    NASA Astrophysics Data System (ADS)

    Achara, Bitrus Emmanuel; Mohammed, Bashar S.; Fadhil Nuruddin, Muhd

    2017-05-01

    Evaluation of the effects of nano-silica amount and superplasticizer (SP) dosage on the compressive strength, porosity and slump flow on high-volume fly ash self-consolidating mortar was investigated. Multiobjective optimisation technique using Design-Expert software was applied to obtain solution based on desirability function that simultaneously optimises the variables and the responses. A desirability function of 0.811 gives the optimised solution. The experimental and predicted results showed minimal errors in all the measured responses.

  7. A dissociation between stopping and switching actions following a lesion of the pre-supplementary motor area

    PubMed Central

    Roberts, R. Edward; Husain, Masud

    2015-01-01

    Introduction Although the pre-supplementary motor area (pre-SMA) is one of the most frequently reported areas of activation in functional imaging studies, the role of this brain region in cognition is still a matter of intense debate. Here we present a patient with a focal lesion of caudal pre-SMA who displays a selective deficit in updating a response plan to switch actions, but shows no impairment when required to withhold a response – stopping. Materials & methods The patient and a control group underwent three tasks designed to measure different aspects of cognitive control and executive function. Results The pre-SMA patient displayed no impairment when responding in the face of distracting stimuli (Eriksen flanker paradigm), or when required to halt an on-going response (STOP task). However, a specific deficit was observed when she was required to rapidly switch between response plans (CHANGE task). Conclusions These findings suggest that the caudal pre-SMA may have a particularly important role in a network of brain regions required for rapidly updating and implementing response plans. The lack of any significant impairment on other measures of cognitive control suggests that this is not likely due to a global deficit in cognitive control. We discuss the implications of these results in the context of current theories of pre-SMA function. PMID:25282056

  8. Thin film devices used as oxygen partial pressure sensors

    NASA Technical Reports Server (NTRS)

    Canady, K. S.; Wortman, J. J.

    1970-01-01

    Electrical conductivity of zinc oxide films to be used in an oxygen partial pressure sensor is measured as a function of temperature, oxygen partial pressure, and other atmospheric constituents. Time response following partial pressure changes is studied as a function of temperature and environmental changes.

  9. Changes of brain response induced by simulated weightlessness

    NASA Astrophysics Data System (ADS)

    Wei, Jinhe; Yan, Gongdong; Guan, Zhiqiang

    The characteristics change of brain response was studied during 15° head-down tilt (HDT) comparing with 45° head-up tilt (HUT). The brain responses evaluated included the EEG power spectra change at rest and during mental arithmetic, and the event-related potentials (ERPs) of somatosensory, selective attention and mental arithmetic activities. The prominent feature of brain response change during HDT revealed that the brain function was inhibited to some extent. Such inhibition included that the significant increment of "40Hz" activity during HUT arithmetic almost disappeared during HDT arithmetic, and that the positive-potential effect induced by HDT presented in all kinds of ERPs measured, but the slow negative wave reflecting mental arithmetic and memory process was elongated. These data suggest that the brain function be affected profoundly by the simulated weightlessness, therefore, the brain function change during space flight should be studied systematically.

  10. Optimization of actuator arrays for aircraft interior noise control

    NASA Technical Reports Server (NTRS)

    Cabell, R. H.; Lester, H. C.; Mathur, G. P.; Tran, B. N.

    1993-01-01

    A numerical procedure for grouping actuators in order to reduce the number of degrees of freedom in an active noise control system is evaluated using experimental data. Piezoceramic actuators for reducing aircraft interior noise are arranged into groups using a nonlinear optimization routine and clustering algorithm. An actuator group is created when two or more actuators are driven with the same control input. This procedure is suitable for active control applications where actuators are already mounted on a structure. The feasibility of this technique is demonstrated using measured data from the aft cabin of a Douglas DC-9 fuselage. The measured data include transfer functions between 34 piezoceramic actuators and 29 interior microphones and microphone responses due to the primary noise produced by external speakers. Control inputs for the grouped actuators were calculated so that a cost function, defined as a quadratic pressure term and a penalty term, was a minimum. The measured transfer functions and microphone responses are checked by comparing calculated noise reductions with measured noise reductions for four frequencies. The grouping procedure is then used to determine actuator groups that improve overall interior noise reductions by 5.3 to 15 dB, compared to the baseline experimental configuration.

  11. Mental fatigue detection based on the functional near infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Zhang, Zhen; Xu, Fenggang; Yang, Hanjun; Jiang, Jin; Cao, Yong; Jiao, Xuejun

    2017-02-01

    Mental fatigue can be induced by long time mental work, mental fatigue caused worse performance and accidents. As a non-invasive technique, functional near-infrared spectroscopy (fNIRS) can measure blood oxygen activity in the cerebral cortex which reflect the cognitive function of brain indirectly. Aiming at investigating whether fNIRS can measure the mental fatigue and study the spatial pattern of hemodynamic response for mental fatigue, we used three sessions of verbal 2-back working memory task for a total of 120 minutes to induce mental fatigue, 15 healthy subjects were recruited and 30 channels including prefrontal cortex (PFC) and motor cortex (MC) were measured by fNIRS. The mean oxyhemoglobin feature for 20s was extracted as well as subjective fatigue level and performance. The results showed significant increase of subjected fatigue level as well as significant decrease performance from session one to three task. With the increased level of fatigue, oxyhemoglobin in PFC increase significantly and the spatial pattern of hemodynamic response in the all 30 channels varied with task duration as well. These findings indicated the potential of fNIRS measured hemodynamic as a mental fatigue indicator.

  12. Validation of a short form of the Western Ontario and McMaster Universities Osteoarthritis Index function subscale in hip and knee osteoarthritis.

    PubMed

    Baron, Gabriel; Tubach, Florence; Ravaud, Philippe; Logeart, Isabelle; Dougados, Maxime

    2007-05-15

    A short version of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) function scale has recently been developed to enhance the applicability of the scale in routine practice and clinical research for patients with hip and knee osteoarthritis. The goal of the present study was to validate this short form. We conducted a prospective 4-week cohort study of 1,036 outpatients. Performance on the WOMAC function long form (LF) and short form (SF) was compared. Agreement between responses on the 2 forms was examined according to a Bland-Altman plot. Responsiveness to change (by standardized response mean [SRM]), reproducibility (intraclass correlation coefficient [ICC]), and internal consistency (Cronbach's alpha) were computed for both forms. Construct validity was assessed based on functional impairment as measured on a numerical rating scale. At baseline, 24% of patients who completed the WOMAC LF had missing data for at least 1 item as compared with only 6% of patients who completed the WOMAC SF. The mean WOMAC SF score was greater than the mean WOMAC LF score (mean +/- SD difference -4.3 +/- 4.8 on a 0-100 scale). SRMs were 0.61 and 0.73, ICCs were 0.76 and 0.68, and Cronbach's alphas were 0.93 and 0.85 for the WOMAC LF and SF, respectively. The 2 forms had comparable correlation with functional impairment. The WOMAC function short form has a low rate of missing data and is a responsive, reproducible, and valid measure. The mean SF score was 4 points higher than the mean LF score.

  13. Task-Specific and General Cognitive Effects in Chiari Malformation Type I

    PubMed Central

    Allen, Philip A.; Houston, James R.; Pollock, Joshua W.; Buzzelli, Christopher; Li, Xuan; Harrington, A. Katherine; Martin, Bryn A.; Loth, Francis; Lien, Mei-Ching; Maleki, Jahangir; Luciano, Mark G.

    2014-01-01

    Objective Our objective was to use episodic memory and executive function tests to determine whether or not Chiari Malformation Type I (CM) patients experience cognitive dysfunction. Background CM is a neurological syndrome in which the cerebellum descends into the cervical spine causing neural compression, severe headaches, neck pain, and number of other physical symptoms. While primarily a disorder of the cervico-medullary junction, both clinicians and researchers have suspected deficits in higher-level cognitive function. Design and Methods We tested 24 CM patients who had undergone decompression neurosurgery and 24 age- and education-matched controls on measures of immediate and delayed episodic memory, as well as three measures of executive function. Results The CM group showed performance decrements relative to the controls in response inhibition (Stroop interference), working memory computational speed (Ospan), and processing speed (automated digit symbol substitution task), but group differences in recall did not reach statistical significance. After statistical control for depression and anxiety scores, the group effects for working memory and processing speed were eliminated, but not for response inhibition. This response inhibition difference was not due to overall general slowing for the CM group, either, because when controls' data were transformed using the linear function fit to all of the reaction time tasks, the interaction with group remained statistically significant. Furthermore, there was a multivariate group effect for all of the response time measures and immediate and delayed recall after statistical control of depression and anxiety scores. Conclusion These results suggest that CM patients with decompression surgery exhibit cognitive dysfunction compared to age- and education-matched controls. While some of these results may be related to anxiety and depression (likely proxies for chronic pain), response inhibition effects, in particular, as well as a general cognitive deficit persisted even after control for anxiety and decompression. PMID:24736676

  14. A Scoping Review of Physical Performance Outcome Measures Used in Exercise Interventions for Older Adults With Alzheimer Disease and Related Dementias.

    PubMed

    McGough, Ellen L; Lin, Shih-Yin; Belza, Basia; Becofsky, Katie M; Jones, Dina L; Liu, Minhui; Wilcox, Sara; Logsdon, Rebecca G

    2017-11-28

    There is growing evidence that exercise interventions can mitigate functional decline and reduce fall risk in older adults with Alzheimer disease and related dementias (ADRD). Although physical performance outcome measures have been successfully used in older adults without cognitive impairment, additional research is needed regarding their use with individuals who have ADRD, and who may have difficulty following instructions regarding performance of these measures. The purpose of this scoping review was to identify commonly used physical performance outcome measures, for exercise interventions, that are responsive and reliable in older adults with ADRD. Ultimately, we aimed to provide recommendations regarding the use of outcome measures for individuals with ADRD across several domains of physical performance. A scoping review was conducted to broadly assess physical performance outcome measures used in exercise interventions for older adults with ADRD. Exercise intervention studies that included at least 1 measure of physical performance were included. All physical performance outcome measures were abstracted, coded, and categorized into 5 domains of physical performance: fitness, functional mobility, gait, balance, and strength. Criteria for recommendations were based on (1) the frequency of use, (2) responsiveness, and (3) reliability. Frequency was determined by the number of studies that used the outcome measure per physical performance domain. Responsiveness was assessed via calculated effect size of the outcome measures across studies within physical performance domains. Reliability was evaluated via published studies of psychometric properties. A total of 20 physical performance outcome measures were extracted from 48 articles that met study inclusion criteria. The most frequently used outcome measures were the 6-minute walk test, Timed Up and Go, repeated chair stand tests, short-distance gait speed, the Berg Balance Scale, and isometric strength measures. These outcome measures demonstrated a small, medium, or large effect in at least 50% of the exercise intervention studies. Good to excellent reliability was reported in samples of older adults with mild to moderate dementia. Fitness, functional mobility, gait, balance, and strength represent important domains of physical performance for older adults. The 6-minute walk test, Timed Up and Go, repeated chair stand tests, short-distance gait speed, Berg Balance Scale, and isometric strength are recommended as commonly used and reliable physical performance outcome measures for exercise interventions in older adults with mild to moderate ADRD. Further research is needed on optimal measures for individuals with severe ADRD. The results of this review will aid clinicians and researchers in selecting reliable measures to evaluate physical performance outcomes in response to exercise interventions in older adults with ADRD.

  15. Shock response of poly[methyl methacrylate] (PMMA) measured with embedded electromagnetic gauges

    NASA Astrophysics Data System (ADS)

    Lacina, David; Neel, Christopher; Dattelbaum, Dana

    2018-05-01

    The shock response of poly[methyl methacrylate] (PMMA) acquired from two providers, Spartech and Rohm & Haas, has been measured to investigate the shock response variations related to material pedigree. These measurements have also been used to examine the effects of viscoelasticity on Spartech PMMA. Measurements of the Hugoniot curves, release wave speeds, and index of refraction have been acquired up to previously unexplored stresses, ˜10.7 GPa, for Spartech PMMA. In-situ, time-resolved particle velocity wave profiles, as a function of time and depth, were obtained using twelve separate electromagnetic gauge elements embedded at different depths in the PMMA. A comparison of the new data to the shock response data for Rohm and Haas PMMA, used as a "standard" material in shock compression studies, shows that there are no significant differences in shock response for the two materials. From the index of refraction measurements, the apparent particle velocity correction for a PMMA window exhibits an interesting oscillation, increasing at up = 0.3 km/s after decreasing up to that point. The results are generalized into guidelines for sourcing PMMA for use in shock studies.

  16. Reduced order modeling, statistical analysis and system identification for a bladed rotor with geometric mistuning

    NASA Astrophysics Data System (ADS)

    Vishwakarma, Vinod

    Modified Modal Domain Analysis (MMDA) is a novel method for the development of a reduced-order model (ROM) of a bladed rotor. This method utilizes proper orthogonal decomposition (POD) of Coordinate Measurement Machine (CMM) data of blades' geometries and sector analyses using ANSYS. For the first time ROM of a geometrically mistuned industrial scale rotor (Transonic rotor) with large size of Finite Element (FE) model is generated using MMDA. Two methods for estimating mass and stiffness mistuning matrices are used a) exact computation from sector FE analysis, b) estimates based on POD mistuning parameters. Modal characteristics such as mistuned natural frequencies, mode shapes and forced harmonic response are obtained from ROM for various cases, and results are compared with full rotor ANSYS analysis and other ROM methods such as Subset of Nominal Modes (SNM) and Fundamental Model of Mistuning (FMM). Accuracy of MMDA ROM is demonstrated with variations in number of POD features and geometric mistuning parameters. It is shown for the aforementioned case b) that the high accuracy of ROM studied in previous work with Academic rotor does not directly translate to the Transonic rotor. Reasons for such mismatch in results are investigated and attributed to higher mistuning in Transonic rotor. Alternate solutions such as estimation of sensitivities via least squares, and interpolation of mass and stiffness matrices on manifolds are developed, and their results are discussed. Statistics such as mean and standard deviations of forced harmonic response peak amplitude are obtained from random permutations, and are shown to have similar results as those of Monte Carlo simulations. These statistics are obtained and compared for 3 degree of freedom (DOF) lumped parameter model (LPM) of rotor, Academic rotor and Transonic rotor. A state -- estimator based on MMDA ROM and Kalman filter is also developed for offline or online estimation of harmonic forcing function from measurements of forced response. Forcing function is estimated for synchronous excitation of 3DOF rotor model, Academic rotor and Transonic rotor from measurement of response at few nodes. For asynchronous excitation forcing function is estimated only for 3DOF rotor model and Academic rotor from measurement of response. The impact of number of measurement locations and accuracy of ROM on the estimation of forcing function is discussed. iv.

  17. The Brain Basis for Misophonia.

    PubMed

    Kumar, Sukhbinder; Tansley-Hancock, Olana; Sedley, William; Winston, Joel S; Callaghan, Martina F; Allen, Micah; Cope, Thomas E; Gander, Phillip E; Bamiou, Doris-Eva; Griffiths, Timothy D

    2017-02-20

    Misophonia is an affective sound-processing disorder characterized by the experience of strong negative emotions (anger and anxiety) in response to everyday sounds, such as those generated by other people eating, drinking, chewing, and breathing [1-8]. The commonplace nature of these sounds (often referred to as "trigger sounds") makes misophonia a devastating disorder for sufferers and their families, and yet nothing is known about the underlying mechanism. Using functional and structural MRI coupled with physiological measurements, we demonstrate that misophonic subjects show specific trigger-sound-related responses in brain and body. Specifically, fMRI showed that in misophonic subjects, trigger sounds elicit greatly exaggerated blood-oxygen-level-dependent (BOLD) responses in the anterior insular cortex (AIC), a core hub of the "salience network" that is critical for perception of interoceptive signals and emotion processing. Trigger sounds in misophonics were associated with abnormal functional connectivity between AIC and a network of regions responsible for the processing and regulation of emotions, including ventromedial prefrontal cortex (vmPFC), posteromedial cortex (PMC), hippocampus, and amygdala. Trigger sounds elicited heightened heart rate (HR) and galvanic skin response (GSR) in misophonic subjects, which were mediated by AIC activity. Questionnaire analysis showed that misophonic subjects perceived their bodies differently: they scored higher on interoceptive sensibility than controls, consistent with abnormal functioning of AIC. Finally, brain structural measurements implied greater myelination within vmPFC in misophonic individuals. Overall, our results show that misophonia is a disorder in which abnormal salience is attributed to particular sounds based on the abnormal activation and functional connectivity of AIC. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  18. Bifactor and Item Response Theory Analyses of Interviewer Report Scales of Cognitive Impairment in Schizophrenia

    PubMed Central

    Reise, Steven P.; Ventura, Joseph; Keefe, Richard S. E.; Baade, Lyle E.; Gold, James M.; Green, Michael F.; Kern, Robert S.; Mesholam-Gately, Raquelle; Nuechterlein, Keith H.; Seidman, Larry J.; Bilder, Robert

    2011-01-01

    We conducted psychometric analyses of two interview-based measures of cognitive deficits: the 21-item Clinical Global Impression of Cognition in Schizophrenia (CGI-CogS; Ventura et al., 2008), and the 20-item Schizophrenia Cognition Rating Scale (SCoRS; Keefe et al., 2006), which were administered on two occasions to a sample of people with schizophrenia. Traditional psychometrics, bifactor analysis, and item response theory (IRT) methods were used to explore item functioning, dimensionality, and to compare instruments. Despite containing similar item content, responses to the CGI-CogS demonstrated superior psychometric properties (e.g., higher item-intercorrelations, better spread of ratings across response categories), relative to the SCoRS. We argue that these differences arise mainly from the differential use of prompts and how the items are phrased and scored. Bifactor analysis demonstrated that although both measures capture a broad range of cognitive functioning (e.g., working memory, social cognition), the common variance on each is overwhelmingly explained by a single general factor. IRT analyses of the combined pool of 41 items showed that measurement precision is peaked in the mild to moderate range of cognitive impairment. Finally, simulated adaptive testing revealed that only about 10 to 12 items are necessary to achieve latent trait level estimates with reasonably small standard errors for most individuals. This suggests that these interview-based measures of cognitive deficits could be shortened without loss of measurement precision. PMID:21381848

  19. Characterization of EJ-200 plastic scintillators as active background shield for cosmogenic radiation

    NASA Astrophysics Data System (ADS)

    Tkaczyk, A. H.; Saare, H.; Ipbüker, C.; Schulte, F.; Mastinu, P.; Paepen, J.; Pedersen, B.; Schillebeeckx, P.; Varasano, G.

    2018-02-01

    This paper describes the characterization of commercially available plastic scintillation detectors to be used as an active shield or veto system to reduce the neutron background resulting from atmospheric muon interactions in low-level nuclear waste assay systems. The shield consists of an array of scintillation detectors surrounding a neutron detection system. Scintillation detectors with different thicknesses are characterized for their response to gamma rays, neutrons, and muons. Response functions to gamma rays were determined and measured in the energy range from 0.6 MeV to 6.0 MeV using radionuclide sources. Neutron response functions were derived from results of time-of-flight measurements at the Van de Graaff accelerator of the INFN Legnaro and from measurements with quasi mono-energetic neutron beams produced at the Van de Graaff accelerator of the JRC Geel. From these data, the light output and resolution functions for protons and electrons were derived. The response to muons was verified by background measurements, i.e. without the presence of any neutron or gamma source. It was found that the muon peak is more pronounced when the detectors are placed horizontally. The results indicate that a scintillator with a minimum thickness of 20 mm is needed to separate events due to atmospheric muons from natural gamma ray background, and contributions due to neutron production in nuclear waste based on only the total energy deposition in the detector. In addition, it was shown that muons can be identified with a coincidence pattern when the detectors are stacked. The effectiveness of the proposed system was demonstrated based on muon induced spallation reactions in a lead sample.

  20. Effects of L-histidine depletion and L-tyrosine/L-phenylalanine depletion on sensory and motor processes in healthy volunteers

    PubMed Central

    van Ruitenbeek, P; Sambeth, A; Vermeeren, A; Young, SN; Riedel, WJ

    2009-01-01

    Background and purpose: Animal studies show that histamine plays a role in cognitive functioning and that histamine H3-receptor antagonists, which increase histaminergic function through presynaptic receptors, improve cognitive performance in models of clinical cognitive deficits. In order to test such new drugs in humans, a model for cognitive impairments induced by low histaminergic functions would be useful. Studies with histamine H1-receptor antagonists have shown limitations as a model. Here we evaluated whether depletion of L-histidine, the precursor of histamine, was effective in altering measures associated with histamine in humans and the behavioural and electrophysiological (event-related-potentials) effects. Experimental approach: Seventeen healthy volunteers completed a three-way, double-blind, crossover study with L-histidine depletion, L-tyrosine/L-phenylalanine depletion (active control) and placebo as treatments. Interactions with task manipulations in a choice reaction time task were studied. Task demands were increased using visual stimulus degradation and increased response complexity. In addition, subjective and objective measures of sedation and critical tracking task performance were assessed. Key results: Measures of sedation and critical tracking task performance were not affected by treatment. L-histidine depletion was effective and enlarged the effect of response complexity as measured with the response-locked lateralized readiness potential onset latency. Conclusions and implications: L-histidine depletion affected response- but not stimulus-related processes, in contrast to the effects of H1-receptor antagonists which were previously found to affect primarily stimulus-related processes. L-histidine depletion is promising as a model for histamine-based cognitive impairment. However, these effects need to be confirmed by further studies. PMID:19413574

  1. Dissociation of face-selective cortical responses by attention.

    PubMed

    Furey, Maura L; Tanskanen, Topi; Beauchamp, Michael S; Avikainen, Sari; Uutela, Kimmo; Hari, Riitta; Haxby, James V

    2006-01-24

    We studied attentional modulation of cortical processing of faces and houses with functional MRI and magnetoencephalography (MEG). MEG detected an early, transient face-selective response. Directing attention to houses in "double-exposure" pictures of superimposed faces and houses strongly suppressed the characteristic, face-selective functional MRI response in the fusiform gyrus. By contrast, attention had no effect on the M170, the early, face-selective response detected with MEG. Late (>190 ms) category-related MEG responses elicited by faces and houses, however, were strongly modulated by attention. These results indicate that hemodynamic and electrophysiological measures of face-selective cortical processing complement each other. The hemodynamic signals reflect primarily late responses that can be modulated by feedback connections. By contrast, the early, face-specific M170 that was not modulated by attention likely reflects a rapid, feed-forward phase of face-selective processing.

  2. Exploring Outcome Measures for Exercise Intervention in People with Parkinson's Disease

    PubMed Central

    King, L. A.; Salarian, A.; Mancini, M.; Priest, K. C.; Nutt, J.; Serdar, A.; Wilhelm, J.; Schlimgen, J.; Smith, M.; Horak, F. B.

    2013-01-01

    Background. It is widely believed that exercise improves mobility in people with Parkinson's disease (PD). However, it is difficult to determine whether a specific type of exercise is the most effective. The purpose of this study was to determine which outcome measures were sensitive to exercise intervention and to explore the effects of two different exercise programs for improving mobility in patients with PD. Methods. Participants were randomized into either the Agility Boot Camp (ABC) or treadmill training; 4x/week for 4 weeks. Outcome measures were grouped by the International Classification of Function/Disability (ICF). To determine the responsiveness to exercise, we calculated the standardized response means. t-tests were used to compare the relative benefits of each exercise program. Results. Four of five variables at the structure/function level changed after exercise: turn duration (P = 0.03), stride velocity (P = 0.001), peak arm speed (P = 0.001), and horizontal trunk ROM during gait (P = 0.02). Most measures improved similarly for both interventions. The only variable that detected a difference between groups was postural sway in ABC group (F = 4.95; P = 0.03). Conclusion. Outcome measures at ICF body structure/function level were most effective at detecting change after exercise and revealing differences in improvement between interventions. PMID:23738230

  3. Virological Outcome after Structured Interruption of Antiretroviral Therapy for Human Immunodeficiency Virus Infection Is Associated with the Functional Profile of Virus-Specific CD8+ T Cells▿

    PubMed Central

    Daucher, Marybeth; Price, David A.; Brenchley, Jason M.; Lamoreaux, Laurie; Metcalf, Julia A.; Rehm, Catherine; Nies-Kraske, Elizabeth; Urban, Elizabeth; Yoder, Christian; Rock, Diane; Gumkowski, Julie; Betts, Michael R.; Dybul, Mark R.; Douek, Daniel C.

    2008-01-01

    A clear understanding of the antiviral effects of CD8+ T cells in the context of chronic human immunodeficiency virus (HIV) infection is critical for the development of prophylactic vaccines and therapeutics designed to support T-cell-mediated immunity. However, defining the potential correlates of effective CD8+ T-cell immunity has proven difficult; notably, comprehensive analyses have demonstrated that the size and shape of the CD8+ T-cell response are not necessarily indicative of efficacy determined by measures of plasma viral load. Here, we conducted a detailed quantitative and qualitative analysis of CD8+ T-cell responses to autologous virus in a cohort of six HIV-infected individuals with a history of structured interruption of antiretroviral therapy (ART) (SIT). The magnitude and breadth of the HIV-specific response did not, by themselves, explain the changes observed in plasma virus levels after the cessation of ART. Furthermore, mutational escape from targeted epitopes could not account for the differential virological outcomes in this cohort. However, the functionality of HIV-specific CD8+ T-cell populations upon antigen encounter, determined by the simultaneous and independent measurement of five CD8+ T-cell functions (degranulation and gamma interferon, macrophage inflammatory protein 1β, tumor necrosis factor alpha, and interleukin-2 levels) reflected the emergent level of plasma virus, with multiple functions being elicited in those individuals with lower levels of viremia after SIT. These data show that the quality of the HIV-specific CD8+ T-cell response, rather than the quantity, is associated with the dynamics of viral replication in the absence of ART and suggest that the effects of SIT can be assessed by measuring the functional profile of HIV-specific CD8+ T cells. PMID:18234797

  4. Refining the Pediatric Evaluation of Disability Inventory-Patient-Reported Outcome (PEDI-PRO) item candidates: interpretation of a self-reported outcome measure of functional performance by young people with neurodevelopmental disabilities.

    PubMed

    Kramer, Jessica M; Schwartz, Ariel

    2017-10-01

    This study examined the item interpretability and rating scale use of the Pediatric Evaluation of Disability Inventory-Patient-Reported Outcome (PEDI-PRO) by young people with developmental disabilities. The PEDI-PRO assesses the functional performance of discrete functional tasks in the context of everyday life situations. A two-phase cognitive interview design was implemented with a convenience sample of 37 young people (mean age 19y, SD 2y 5mo; 13 males and 24 females; 68% with intellectual disability) with developmental disabilities. In phase I, 182 item candidates were each reviewed by an average of four young people. In phase II, 103 items were carried forward or revised and each reviewed by an average of seven additional young people. Two raters coded responses for intended item interpretation and performance quality; codes were analysed using descriptive statistics. Qualitative analysis explored young people's self-evaluation process. Items were interpreted as intended by most young people (mean 86%). Young people can use PEDI-PRO response categories appropriately to describe their performance: 94% of positive performance descriptions coincided with a positive response category choice; 73% of negative descriptions coincided with a negative response category choice. Young people interpreted items in a literal manner, and their self-evaluation incorporated the use of supports that facilitate functional performance. The PEDI-PRO's measurement framework appears to support the self-evaluation of functional performance of young people with developmental disabilities. © 2017 Mac Keith Press.

  5. Sleep and pulmonary outcomes for clinical trials of airway plexiform neurofibromas in NF1.

    PubMed

    Plotkin, Scott R; Davis, Stephanie D; Robertson, Kent A; Akshintala, Srivandana; Allen, Julian; Fisher, Michael J; Blakeley, Jaishri O; Widemann, Brigitte C; Ferner, Rosalie E; Marcus, Carole L

    2016-08-16

    Plexiform neurofibromas (PNs) are complex, benign nerve sheath tumors that occur in approximately 25%-50% of individuals with neurofibromatosis type 1 (NF1). PNs that cause airway compromise or pulmonary dysfunction are uncommon but clinically important. Because improvement in sleep quality or airway function represents direct clinical benefit, measures of sleep and pulmonary function may be more meaningful than tumor size as endpoints in therapeutic clinical trials targeting airway PN. The Response Evaluation in Neurofibromatosis and Schwannomatosis functional outcomes group reviewed currently available endpoints for sleep and pulmonary outcomes and developed consensus recommendations for response evaluation in NF clinical trials. For patients with airway PNs, polysomnography, impulse oscillometry, and spirometry should be performed to identify abnormal function that will be targeted by the agent under clinical investigation. The functional group endorsed the use of the apnea hypopnea index (AHI) as the primary sleep endpoint, and pulmonary resistance at 10 Hz (R10) or forced expiratory volume in 1 or 0.75 seconds (FEV1 or FEV0.75) as primary pulmonary endpoints. The group defined minimum changes in AHI, R10, and FEV1 or FEV0.75 for response criteria. Secondary sleep outcomes include desaturation and hypercapnia during sleep and arousal index. Secondary pulmonary outcomes include pulmonary resistance and reactance measurements at 5, 10, and 20 Hz; forced vital capacity; peak expiratory flow; and forced expiratory flows. These recommended sleep and pulmonary evaluations are intended to provide researchers with a standardized set of clinically meaningful endpoints for response evaluation in trials of NF1-related airway PNs. © 2016 American Academy of Neurology.

  6. Review of methods for measuring β-cell function: Design considerations from the Restoring Insulin Secretion (RISE) Consortium.

    PubMed

    Hannon, Tamara S; Kahn, Steven E; Utzschneider, Kristina M; Buchanan, Thomas A; Nadeau, Kristen J; Zeitler, Philip S; Ehrmann, David A; Arslanian, Silva A; Caprio, Sonia; Edelstein, Sharon L; Savage, Peter J; Mather, Kieren J

    2018-01-01

    The Restoring Insulin Secretion (RISE) study was initiated to evaluate interventions to slow or reverse the progression of β-cell failure in type 2 diabetes (T2D). To design the RISE study, we undertook an evaluation of methods for measurement of β-cell function and changes in β-cell function in response to interventions. In the present paper, we review approaches for measurement of β-cell function, focusing on methodologic and feasibility considerations. Methodologic considerations included: (1) the utility of each technique for evaluating key aspects of β-cell function (first- and second-phase insulin secretion, maximum insulin secretion, glucose sensitivity, incretin effects) and (2) tactics for incorporating a measurement of insulin sensitivity in order to adjust insulin secretion measures for insulin sensitivity appropriately. Of particular concern were the capacity to measure β-cell function accurately in those with poor function, as is seen in established T2D, and the capacity of each method for demonstrating treatment-induced changes in β-cell function. Feasibility considerations included: staff burden, including time and required methodological expertise; participant burden, including time and number of study visits; and ease of standardizing methods across a multicentre consortium. After this evaluation, we selected a 2-day measurement procedure, combining a 3-hour 75-g oral glucose tolerance test and a 2-stage hyperglycaemic clamp procedure, augmented with arginine. © 2017 John Wiley & Sons Ltd.

  7. A Noise Level Prediction Method Based on Electro-Mechanical Frequency Response Function for Capacitors

    PubMed Central

    Zhu, Lingyu; Ji, Shengchang; Shen, Qi; Liu, Yuan; Li, Jinyu; Liu, Hao

    2013-01-01

    The capacitors in high-voltage direct-current (HVDC) converter stations radiate a lot of audible noise which can reach higher than 100 dB. The existing noise level prediction methods are not satisfying enough. In this paper, a new noise level prediction method is proposed based on a frequency response function considering both electrical and mechanical characteristics of capacitors. The electro-mechanical frequency response function (EMFRF) is defined as the frequency domain quotient of the vibration response and the squared capacitor voltage, and it is obtained from impulse current experiment. Under given excitations, the vibration response of the capacitor tank is the product of EMFRF and the square of the given capacitor voltage in frequency domain, and the radiated audible noise is calculated by structure acoustic coupling formulas. The noise level under the same excitations is also measured in laboratory, and the results are compared with the prediction. The comparison proves that the noise prediction method is effective. PMID:24349105

  8. Response Surface Modeling Using Multivariate Orthogonal Functions

    NASA Technical Reports Server (NTRS)

    Morelli, Eugene A.; DeLoach, Richard

    2001-01-01

    A nonlinear modeling technique was used to characterize response surfaces for non-dimensional longitudinal aerodynamic force and moment coefficients, based on wind tunnel data from a commercial jet transport model. Data were collected using two experimental procedures - one based on modem design of experiments (MDOE), and one using a classical one factor at a time (OFAT) approach. The nonlinear modeling technique used multivariate orthogonal functions generated from the independent variable data as modeling functions in a least squares context to characterize the response surfaces. Model terms were selected automatically using a prediction error metric. Prediction error bounds computed from the modeling data alone were found to be- a good measure of actual prediction error for prediction points within the inference space. Root-mean-square model fit error and prediction error were less than 4 percent of the mean response value in all cases. Efficacy and prediction performance of the response surface models identified from both MDOE and OFAT experiments were investigated.

  9. A noise level prediction method based on electro-mechanical frequency response function for capacitors.

    PubMed

    Zhu, Lingyu; Ji, Shengchang; Shen, Qi; Liu, Yuan; Li, Jinyu; Liu, Hao

    2013-01-01

    The capacitors in high-voltage direct-current (HVDC) converter stations radiate a lot of audible noise which can reach higher than 100 dB. The existing noise level prediction methods are not satisfying enough. In this paper, a new noise level prediction method is proposed based on a frequency response function considering both electrical and mechanical characteristics of capacitors. The electro-mechanical frequency response function (EMFRF) is defined as the frequency domain quotient of the vibration response and the squared capacitor voltage, and it is obtained from impulse current experiment. Under given excitations, the vibration response of the capacitor tank is the product of EMFRF and the square of the given capacitor voltage in frequency domain, and the radiated audible noise is calculated by structure acoustic coupling formulas. The noise level under the same excitations is also measured in laboratory, and the results are compared with the prediction. The comparison proves that the noise prediction method is effective.

  10. Bruel and Kjaer 4944 Microphone Grid Frequency Response Function System Identification

    NASA Technical Reports Server (NTRS)

    Bennett, Reginald; Lee, Erik

    2010-01-01

    Br el & Kjaer (B&K) 4944B pressure field microphone was judiciously selected to measure acoustic environments, 400Hz 50kHz, in close proximity of the nozzle during multiple firings of solid propellant rocket motors. It is well known that protective grids can affect the frequency response of microphones. B&K recommends operation of the B&K 4944B without a protective grid when recording measurements above 10 to 15 kHz.

  11. Differences in executive functioning between violent and non-violent offenders.

    PubMed

    Meijers, J; Harte, J M; Meynen, G; Cuijpers, P

    2017-07-01

    A growing body of neuropsychological and neurobiological research shows a relationship between functioning of the prefrontal cortex and criminal and violent behaviour. The prefrontal cortex is crucial for executive functions such as inhibition, attention, working memory, set-shifting and planning. A deficit in these functions - a prefrontal deficit - may result in antisocial, impulsive or even aggressive behaviour. While several meta-analyses show large effect sizes for the relationship between a prefrontal deficit, executive dysfunction and criminality, there are few studies investigating differences in executive functions between violent and non-violent offenders. Considering the relevance of identifying risk factors for violent offending, the current study explores whether a distinction between violent and non-violent offenders can be made using an extensive neuropsychological test battery. Male remand prisoners (N = 130) in Penitentiary Institution Amsterdam Over-Amstel were administered an extensive neuropsychological test battery (Cambridge Automated Neuropsychological Test Battery; CANTAB) measuring response inhibition, planning, attention, set-shifting, working memory and impulsivity/reward sensitivity. Violent offenders performed significantly worse on the stop-signal task (partial correlation r = 0.205, p = 0.024), a task measuring response inhibition. No further differences were found between violent and non-violent offenders. Explorative analyses revealed a significant relationship between recidivism and planning (partial correlation r = -0.209, p = 0.016). Violent offenders show worse response inhibition compared to non-violent offenders, suggesting a more pronounced prefrontal deficit in violent offenders than in non-violent offenders.

  12. Use of an improved radiation amplification factor to estimate the effect of total ozone changes on action spectrum weighted irradiances and an instrument response function

    NASA Astrophysics Data System (ADS)

    Herman, Jay R.

    2010-12-01

    Multiple scattering radiative transfer results are used to calculate action spectrum weighted irradiances and fractional irradiance changes in terms of a power law in ozone Ω, U(Ω/200)-RAF, where the new radiation amplification factor (RAF) is just a function of solar zenith angle. Including Rayleigh scattering caused small differences in the estimated 30 year changes in action spectrum-weighted irradiances compared to estimates that neglect multiple scattering. The radiative transfer results are applied to several action spectra and to an instrument response function corresponding to the Solar Light 501 meter. The effect of changing ozone on two plant damage action spectra are shown for plants with high sensitivity to UVB (280-315 nm) and those with lower sensitivity, showing that the probability for plant damage for the latter has increased since 1979, especially at middle to high latitudes in the Southern Hemisphere. Similarly, there has been an increase in rates of erythemal skin damage and pre-vitamin D3 production corresponding to measured ozone decreases. An example conversion function is derived to obtain erythemal irradiances and the UV index from measurements with the Solar Light 501 instrument response function. An analytic expressions is given to convert changes in erythemal irradiances to changes in CIE vitamin-D action spectrum weighted irradiances.

  13. Use of an Improved Radiation Amplification Factor to Estimate the Effect of Total Ozone Changes on Action Spectrum Weighted Irradiances and an Instrument Response Function

    NASA Technical Reports Server (NTRS)

    Herman, Jay R.

    2010-01-01

    Multiple scattering radiative transfer results are used to calculate action spectrum weighted irradiances and fractional irradiance changes in terms of a power law in ozone OMEGA, U(OMEGA/200)(sup -RAF), where the new radiation amplification factor (RAF) is just a function of solar zenith angle. Including Rayleigh scattering caused small differences in the estimated 30 year changes in action spectrum-weighted irradiances compared to estimates that neglect multiple scattering. The radiative transfer results are applied to several action spectra and to an instrument response function corresponding to the Solar Light 501 meter. The effect of changing ozone on two plant damage action spectra are shown for plants with high sensitivity to UVB (280-315 run) and those with lower sensitivity, showing that the probability for plant damage for the latter has increased since 1979, especially at middle to high latitudes in the Southern Hemisphere. Similarly, there has been an increase in rates of erythemal skin damage and pre-vitamin D3 production corresponding to measured ozone decreases. An example conversion function is derived to obtain erythemal irradiances and the UV index from measurements with the Solar Light 501 instrument response function. An analytic expressions is given to convert changes in erythemal irradiances to changes in CIE vitamin-D action spectrum weighted irradiances.

  14. Cognitive-Behavioral Therapy for Children With Functional Abdominal Pain and Their Parents Decreases Pain and Other Symptoms

    PubMed Central

    Levy, Rona L.; Langer, Shelby L.; Walker, Lynn S.; Romano, Joan M.; Christie, Dennis L.; Youssef, Nader; DuPen, Melissa M.; Feld, Andrew D.; Ballard, Sheri A.; Welsh, Ericka M.; Jeffery, Robert W.; Young, Melissa; Coffey, Melissa J.; Whitehead, William E.

    2011-01-01

    OBJECTIVES Unexplained abdominal pain in children has been shown to be related to parental responses to symptoms. This randomized controlled trial tested the efficacy of an intervention designed to improve outcomes in idiopathic childhood abdominal pain by altering parental responses to pain and children's ways of coping and thinking about their symptoms. METHODS Two hundred children with persistent functional abdominal pain and their parents were randomly assigned to one of two conditions—a three-session intervention of cognitive-behavioral treatment targeting parents' responses to their children's pain complaints and children's coping responses, or a three-session educational intervention that controlled for time and attention. Parents and children were assessed at pretreatment, and 1 week, 3 months, and 6 months post-treatment. Outcome measures were child and parent reports of child pain levels, function, and adjustment. Process measures included parental protective responses to children's symptom reports and child coping methods. RESULTS Children in the cognitive-behavioral condition showed greater baseline to follow-up decreases in pain and gastrointestinal symptom severity (as reported by parents) than children in the comparison condition (time × treatment interaction, P < 0.01). Also, parents in the cognitive-behavioral condition reported greater decreases in solicitous responses to their child's symptoms compared with parents in the comparison condition (time × treatment interaction, P < 0.0001). CONCLUSIONS An intervention aimed at reducing protective parental responses and increasing child coping skills is effective in reducing children's pain and symptom levels compared with an educational control condition. PMID:20216531

  15. Comparison of non-invasive measures of cholinergic and allergic airway responsiveness in rats.

    PubMed

    Glaab, T; Hecker, H; Stephan, M; Baelder, R; Braun, A; Korolewitz, R; Krug, N; Hoymann, H G

    2006-04-01

    Non-invasive analysis of tidal expiratory flow parameters such as Tme/TE (time needed to reach peak expiratory flow divided by total expiratory time) or midexpiratory tidal flow (EF50) has been shown useful for phenotypic characterization of lung function in humans and animal models. In this study, we aimed to compare the utility of two non-invasive measures, EF50 and Tme/TE, to monitor bronchoconstriction to inhaled cholinergic and allergic challenges in Brown-Norway rats. Non-invasive measurements of Tme/TE and EF50 were paralleled by invasive recordings of Tme/TE, EF50 and pulmonary conductance (GL). First, dose-response studies with acetylcholine were performed in naive rats, showing that EF50 better than Tme/TE reflected the dose-related changes as observed with the classical invasive outcome parameter GL. The subsequent determination of allergen-specific early airway responsiveness (EAR) showed that ovalbumin-sensitized and -challenged rats exhibited airway inflammation and allergen-specific EAR. Again, EF50 was more sensitive than Tme/TE in detecting the allergen-specific EAR recorded with invasive and non-invasive lung function methods and agreed well with classical GL measurements. We conclude that non-invasive assessment of EF50 is significantly superior to Tme/TE and serves as a suitable and valid tool for phenotypic screening of cholinergic and allergic airway responsiveness in rats.

  16. Planck 2013 results. VII. HFI time response and beams

    NASA Astrophysics Data System (ADS)

    Planck Collaboration; Ade, P. A. R.; Aghanim, N.; Armitage-Caplan, C.; Arnaud, M.; Ashdown, M.; Atrio-Barandela, F.; Aumont, J.; Baccigalupi, C.; Banday, A. J.; Barreiro, R. B.; Battaner, E.; Benabed, K.; Benoît, A.; Benoit-Lévy, A.; Bernard, J.-P.; Bersanelli, M.; Bielewicz, P.; Bobin, J.; Bock, J. J.; Bond, J. R.; Borrill, J.; Bouchet, F. R.; Bowyer, J. W.; Bridges, M.; Bucher, M.; Burigana, C.; Cardoso, J.-F.; Catalano, A.; Challinor, A.; Chamballu, A.; Chary, R.-R.; Chiang, H. C.; Chiang, L.-Y.; Christensen, P. R.; Church, S.; Clements, D. L.; Colombi, S.; Colombo, L. P. L.; Couchot, F.; Coulais, A.; Crill, B. P.; Curto, A.; Cuttaia, F.; Danese, L.; Davies, R. D.; de Bernardis, P.; de Rosa, A.; de Zotti, G.; Delabrouille, J.; Delouis, J.-M.; Désert, F.-X.; Diego, J. M.; Dole, H.; Donzelli, S.; Doré, O.; Douspis, M.; Dunkley, J.; Dupac, X.; Efstathiou, G.; Enßlin, T. A.; Eriksen, H. K.; Finelli, F.; Forni, O.; Frailis, M.; Fraisse, A. A.; Franceschi, E.; Galeotta, S.; Ganga, K.; Giard, M.; Giraud-Héraud, Y.; González-Nuevo, J.; Górski, K. M.; Gratton, S.; Gregorio, A.; Gruppuso, A.; Gudmundsson, J. E.; Haissinski, J.; Hansen, F. K.; Hanson, D.; Harrison, D.; Henrot-Versillé, S.; Hernández-Monteagudo, C.; Herranz, D.; Hildebrandt, S. R.; Hivon, E.; Hobson, M.; Holmes, W. A.; Hornstrup, A.; Hou, Z.; Hovest, W.; Huffenberger, K. M.; Jaffe, A. H.; Jaffe, T. R.; Jones, W. C.; Juvela, M.; Keihänen, E.; Keskitalo, R.; Kisner, T. S.; Kneissl, R.; Knoche, J.; Knox, L.; Kunz, M.; Kurki-Suonio, H.; Lagache, G.; Lamarre, J.-M.; Lasenby, A.; Laureijs, R. J.; Lawrence, C. R.; Leonardi, R.; Leroy, C.; Lesgourgues, J.; Liguori, M.; Lilje, P. B.; Linden-Vørnle, M.; López-Caniego, M.; Lubin, P. M.; Macías-Pérez, J. F.; MacTavish, C. J.; Maffei, B.; Mandolesi, N.; Maris, M.; Marshall, D. J.; Martin, P. G.; Martínez-González, E.; Masi, S.; Massardi, M.; Matarrese, S.; Matsumura, T.; Matthai, F.; Mazzotta, P.; McGehee, P.; Melchiorri, A.; Mendes, L.; Mennella, A.; Migliaccio, M.; Mitra, S.; Miville-Deschênes, M.-A.; Moneti, A.; Montier, L.; Morgante, G.; Mortlock, D.; Munshi, D.; Murphy, J. A.; Naselsky, P.; Nati, F.; Natoli, P.; Netterfield, C. B.; Nørgaard-Nielsen, H. U.; Noviello, F.; Novikov, D.; Novikov, I.; Osborne, S.; Oxborrow, C. A.; Paci, F.; Pagano, L.; Pajot, F.; Paoletti, D.; Pasian, F.; Patanchon, G.; Perdereau, O.; Perotto, L.; Perrotta, F.; Piacentini, F.; Piat, M.; Pierpaoli, E.; Pietrobon, D.; Plaszczynski, S.; Pointecouteau, E.; Polegre, A. M.; Polenta, G.; Ponthieu, N.; Popa, L.; Poutanen, T.; Pratt, G. W.; Prézeau, G.; Prunet, S.; Puget, J.-L.; Rachen, J. P.; Reinecke, M.; Remazeilles, M.; Renault, C.; Ricciardi, S.; Riller, T.; Ristorcelli, I.; Rocha, G.; Rosset, C.; Roudier, G.; Rowan-Robinson, M.; Rusholme, B.; Sandri, M.; Santos, D.; Sauvé, A.; Savini, G.; Scott, D.; Shellard, E. P. S.; Spencer, L. D.; Starck, J.-L.; Stolyarov, V.; Stompor, R.; Sudiwala, R.; Sureau, F.; Sutton, D.; Suur-Uski, A.-S.; Sygnet, J.-F.; Tauber, J. A.; Tavagnacco, D.; Terenzi, L.; Tomasi, M.; Tristram, M.; Tucci, M.; Umana, G.; Valenziano, L.; Valiviita, J.; Van Tent, B.; Vielva, P.; Villa, F.; Vittorio, N.; Wade, L. A.; Wandelt, B. D.; Yvon, D.; Zacchei, A.; Zonca, A.

    2014-11-01

    This paper characterizes the effective beams, the effective beam window functions and the associated errors for the Planck High Frequency Instrument (HFI) detectors. The effective beam is theangular response including the effect of the optics, detectors, data processing and the scan strategy. The window function is the representation of this beam in the harmonic domain which is required to recover an unbiased measurement of the cosmic microwave background angular power spectrum. The HFI is a scanning instrument and its effective beams are the convolution of: a) the optical response of the telescope and feeds; b) the processing of the time-ordered data and deconvolution of the bolometric and electronic transfer function; and c) the merging of several surveys to produce maps. The time response transfer functions are measured using observations of Jupiter and Saturn and by minimizing survey difference residuals. The scanning beam is the post-deconvolution angular response of the instrument, and is characterized with observations of Mars. The main beam solid angles are determined to better than 0.5% at each HFI frequency band. Observations of Jupiter and Saturn limit near sidelobes (within 5°) to about 0.1% of the total solid angle. Time response residuals remain as long tails in the scanning beams, but contribute less than 0.1% of the total solid angle. The bias and uncertainty in the beam products are estimated using ensembles of simulated planet observations that include the impact of instrumental noise and known systematic effects. The correlation structure of these ensembles is well-described by five error eigenmodes that are sub-dominant to sample variance and instrumental noise in the harmonic domain. A suite of consistency tests provide confidence that the error model represents a sufficient description of the data. The total error in the effective beam window functions is below 1% at 100 GHz up to multipole ℓ ~ 1500, and below 0.5% at 143 and 217 GHz up to ℓ ~ 2000.

  17. Reproducibility assessment of brain responses to visual food stimuli in adults with overweight and obesity.

    PubMed

    Drew Sayer, R; Tamer, Gregory G; Chen, Ningning; Tregellas, Jason R; Cornier, Marc-Andre; Kareken, David A; Talavage, Thomas M; McCrory, Megan A; Campbell, Wayne W

    2016-10-01

    The brain's reward system influences ingestive behavior and subsequently obesity risk. Functional magnetic resonance imaging (fMRI) is a common method for investigating brain reward function. This study sought to assess the reproducibility of fasting-state brain responses to visual food stimuli using BOLD fMRI. A priori brain regions of interest included bilateral insula, amygdala, orbitofrontal cortex, caudate, and putamen. Fasting-state fMRI and appetite assessments were completed by 28 women (n = 16) and men (n = 12) with overweight or obesity on 2 days. Reproducibility was assessed by comparing mean fasting-state brain responses and measuring test-retest reliability of these responses on the two testing days. Mean fasting-state brain responses on day 2 were reduced compared with day 1 in the left insula and right amygdala, but mean day 1 and day 2 responses were not different in the other regions of interest. With the exception of the left orbitofrontal cortex response (fair reliability), test-retest reliabilities of brain responses were poor or unreliable. fMRI-measured responses to visual food cues in adults with overweight or obesity show relatively good mean-level reproducibility but considerable within-subject variability. Poor test-retest reliability reduces the likelihood of observing true correlations and increases the necessary sample sizes for studies. © 2016 The Obesity Society.

  18. Reproducibility assessment of brain responses to visual food stimuli in adults with overweight and obesity

    PubMed Central

    Sayer, R Drew; Tamer, Gregory G; Chen, Ningning; Tregellas, Jason R; Cornier, Marc-Andre; Kareken, David A; Talavage, Thomas M; McCrory, Megan A; Campbell, Wayne W

    2016-01-01

    Objective The brain’s reward system influences ingestive behavior and subsequently, obesity risk. Functional magnetic resonance imaging (fMRI) is a common method for investigating brain reward function. We sought to assess the reproducibility of fasting-state brain responses to visual food stimuli using BOLD fMRI. Methods A priori brain regions of interest included bilateral insula, amygdala, orbitofrontal cortex, caudate, and putamen. Fasting-state fMRI and appetite assessments were completed by 28 women (n=16) and men (n=12) with overweight or obesity on 2 days. Reproducibility was assessed by comparing mean fasting-state brain responses and measuring test-retest reliability of these responses on the 2 testing days. Results Mean fasting-state brain responses on Day 2 were reduced compared to Day 1 in the left insula and right amygdala, but mean Day 1 and Day 2 responses were not different in the other regions of interest. With the exception of the left orbitofrontal cortex response (fair reliability), test-retest reliabilities of brain responses were poor or unreliable. Conclusion fMRI-measured responses to visual food cues in adults with overweight or obesity show relatively good mean-level reproducibility, but considerable within-subject variability. Poor test-retest reliability reduces the likelihood of observing true correlations and increases the necessary sample sizes for studies. PMID:27542906

  19. The Auditory-Brainstem Response to Continuous, Non-repetitive Speech Is Modulated by the Speech Envelope and Reflects Speech Processing

    PubMed Central

    Reichenbach, Chagit S.; Braiman, Chananel; Schiff, Nicholas D.; Hudspeth, A. J.; Reichenbach, Tobias

    2016-01-01

    The auditory-brainstem response (ABR) to short and simple acoustical signals is an important clinical tool used to diagnose the integrity of the brainstem. The ABR is also employed to investigate the auditory brainstem in a multitude of tasks related to hearing, such as processing speech or selectively focusing on one speaker in a noisy environment. Such research measures the response of the brainstem to short speech signals such as vowels or words. Because the voltage signal of the ABR has a tiny amplitude, several hundred to a thousand repetitions of the acoustic signal are needed to obtain a reliable response. The large number of repetitions poses a challenge to assessing cognitive functions due to neural adaptation. Here we show that continuous, non-repetitive speech, lasting several minutes, may be employed to measure the ABR. Because the speech is not repeated during the experiment, the precise temporal form of the ABR cannot be determined. We show, however, that important structural features of the ABR can nevertheless be inferred. In particular, the brainstem responds at the fundamental frequency of the speech signal, and this response is modulated by the envelope of the voiced parts of speech. We accordingly introduce a novel measure that assesses the ABR as modulated by the speech envelope, at the fundamental frequency of speech and at the characteristic latency of the response. This measure has a high signal-to-noise ratio and can hence be employed effectively to measure the ABR to continuous speech. We use this novel measure to show that the ABR is weaker to intelligible speech than to unintelligible, time-reversed speech. The methods presented here can be employed for further research on speech processing in the auditory brainstem and can lead to the development of future clinical diagnosis of brainstem function. PMID:27303286

  20. Reevaluation of the Amsterdam Inventory for Auditory Disability and Handicap Using Item Response Theory.

    PubMed

    Boeschen Hospers, J Mirjam; Smits, Niels; Smits, Cas; Stam, Mariska; Terwee, Caroline B; Kramer, Sophia E

    2016-04-01

    We reevaluated the psychometric properties of the Amsterdam Inventory for Auditory Disability and Handicap (AIADH; Kramer, Kapteyn, Festen, & Tobi, 1995) using item response theory. Item response theory describes item functioning along an ability continuum. Cross-sectional data from 2,352 adults with and without hearing impairment, ages 18-70 years, were analyzed. They completed the AIADH in the web-based prospective cohort study "Netherlands Longitudinal Study on Hearing." A graded response model was fitted to the AIADH data. Category response curves, item information curves, and the standard error as a function of self-reported hearing ability were plotted. The graded response model showed a good fit. Item information curves were most reliable for adults who reported having hearing disability and less reliable for adults with normal hearing. The standard error plot showed that self-reported hearing ability is most reliably measured for adults reporting mild up to moderate hearing disability. This is one of the few item response theory studies on audiological self-reports. All AIADH items could be hierarchically placed on the self-reported hearing ability continuum, meaning they measure the same construct. This provides a promising basis for developing a clinically useful computerized adaptive test, where item selection adapts to the hearing ability of individuals, resulting in efficient assessment of hearing disability.

  1. Functional outcomes in ICU – what should we be using? – an observational study.

    PubMed

    Parry, Selina M; Denehy, Linda; Beach, Lisa J; Berney, Sue; Williamson, Hannah C; Granger, Catherine L

    2015-03-29

    With growing awareness of the importance of rehabilitation, new measures are being developed specifically for use in the intensive care unit (ICU). There are currently 26 measures reported to assess function in ICU survivors. The Physical Function in Intensive care Test scored (PFIT-s) has established clinimetric properties. It is unknown how other functional measures perform in comparison to the PFIT-s or which functional measure may be the most clinically applicable for use within the ICU. The aims of this study were to determine (1) the criterion validity of the Functional Status Score for the ICU (FSS-ICU), ICU Mobility Scale (IMS) and Short Physical Performance Battery (SPPB) against the PFIT-s; (2) the construct validity of these tests against muscle strength; (3) predictive utility of these tests to predict discharge to home; and (4) the clinical applicability. This was a nested study within an ongoing controlled study and an observational study. Sixty-six individuals were assessed at awakening and ICU discharge. Measures included: PFIT-s, FSS-ICU, IMS and SPPB. Bivariate relationships (Spearman's rank correlation coefficient) and predictive validity (logistic regression) were determined. Responsiveness (effect sizes); floor and ceiling effects; and minimal important differences were calculated. Mean ± SD PFIT-s at awakening was 4.7 ± 2.3 out of 10. On awakening a large positive relationship existed between PFIT-s and the other functional measures: FSS-ICU (rho = 0.87, p < 0.005), IMS (rho = 0.81, p < 0.005) and SPPB (rho = 0.70, p < 0.005). The PFIT-s had excellent construct validity (rho = 0.8, p < 0.005) and FSS-ICU (rho = 0.69, p < 0.005) and IMS (rho = 0.57, p < 0.005) had moderate construct validity with muscle strength. The PFIT-s and FSS-ICU had small floor/ceiling effects <11% at awakening and ICU discharge. The SPPB had a large floor effect at awakening (78%) and ICU discharge (56%). All tests demonstrated responsiveness; however highest effect size was seen in the PFIT-s (Cohen's d = 0.71). There is high criterion validity for other functional measures against the PFIT-s. The PFIT-s and FSS-ICU are promising functional measures and are recommended to measure function within the ICU. Clinicaltrials.gov NCT02214823. Registered 7 August 2014).

  2. Attentional and physiological processing of food images in functional dyspepsia patients: A pilot study.

    PubMed

    Lee, In-Seon; Preissl, Hubert; Giel, Katrin; Schag, Kathrin; Enck, Paul

    2018-01-23

    The food-related behavior of functional dyspepsia has been attracting more interest of late. This pilot study aims to provide evidence of the physiological, emotional, and attentional aspects of food processing in functional dyspepsia patients. The study was performed in 15 functional dyspepsia patients and 17 healthy controls after a standard breakfast. We measured autonomic nervous system activity using skin conductance response and heart rate variability, emotional response using facial electromyography, and visual attention using eyetracking during the visual stimuli of food/non-food images. In comparison to healthy controls, functional dyspepsia patients showed a greater craving for food, a decreased intake of food, more dyspeptic symptoms, lower pleasantness rating of food images (particularly of high fat), decreased low frequency/high frequency ratio of heart rate variability, and suppressed total processing time of food images. There were no significant differences of skin conductance response and facial electromyography data between groups. The results suggest that high level cognitive functions rather than autonomic and emotional mechanisms are more liable to function differently in functional dyspepsia patients. Abnormal dietary behavior, reduced subjective rating of pleasantness and visual attention to food should be considered as important pathophysiological characteristics in functional dyspepsia.

  3. Evaluation of a pilot workload metric for simulated VTOL landing tasks

    NASA Technical Reports Server (NTRS)

    North, R. A.; Graffunder, K.

    1979-01-01

    A methodological approach to measuring workload was investigated for evaluation of new concepts in VTOL aircraft displays. Multivariate discriminant functions were formed from conventional flight performance and/or visual response variables to maximize detection of experimental differences. The flight performance variable discriminant showed maximum differentiation between crosswind conditions. The visual response measure discriminant maximized differences between fixed vs. motion base conditions and experimental displays. Physiological variables were used to attempt to predict the discriminant function values for each subject/condition/trial. The weights of the physiological variables in these equations showed agreement with previous studies. High muscle tension, light but irregular breathing patterns, and higher heart rate with low amplitude all produced higher scores on this scale and thus, represented higher workload levels.

  4. Experimental determination of the lateral dose response functions of detectors to be applied in the measurement of narrow photon-beam dose profiles.

    PubMed

    Poppinga, D; Meyners, J; Delfs, B; Muru, A; Harder, D; Poppe, B; Looe, H K

    2015-12-21

    This study aims at the experimental determination of the detector-specific 1D lateral dose response function K(x) and of its associated rotational symmetric counterpart K(r) for a set of high-resolution detectors presently used in narrow-beam photon dosimetry. A combination of slit-beam, radiochromic film, and deconvolution techniques served to accomplish this task for four detectors with diameters of their sensitive volumes ranging from 1 to 2.2 mm. The particular aim of the experiment was to examine the existence of significant negative portions of some of these response functions predicted by a recent Monte-Carlo-simulation (Looe et al 2015 Phys. Med. Biol. 60 6585-607). In a 6 MV photon slit beam formed by the Siemens Artiste collimation system and a 0.5 mm wide slit between 10 cm thick lead blocks serving as the tertiary collimator, the true cross-beam dose profile D(x) at 3 cm depth in a large water phantom was measured with radiochromic film EBT3, and the detector-affected cross-beam signal profiles M(x) were recorded with a silicon diode, a synthetic diamond detector, a miniaturized scintillation detector, and a small ionization chamber. For each detector, the deconvolution of the convolution integral M(x)  =  K(x)  ∗  D(x) served to obtain its specific 1D lateral dose response function K(x), and K(r) was calculated from it. Fourier transformations and back transformations were performed using function approximations by weighted sums of Gaussian functions and their analytical transformation. The 1D lateral dose response functions K(x) of the four types of detectors and their associated rotational symmetric counterparts K(r) were obtained. Significant negative curve portions of K(x) and K(r) were observed in the case of the silicon diode and the diamond detector, confirming the Monte-Carlo-based prediction (Looe et al 2015 Phys. Med. Biol. 60 6585-607). They are typical for the perturbation of the secondary electron field by a detector with enhanced electron density compared with the surrounding water. In the cases of the scintillation detector and the small ionization chamber, the negative curve portions of K(x) practically vanish. It is planned to use the measured functions K(x) and K(r) to deconvolve clinical narrow-beam signal profiles and to correct the output factor values obtained with various high-resolution detectors.

  5. Temperature-induced changes in neuromuscular function: central and peripheral mechanisms.

    PubMed

    Goodman, D; Hancock, P A; Runnings, D W; Brown, S L

    1984-10-01

    Three series of experimental tests were conducted on subjects under both elevated and depressed thermal conditions. Tripartite series consisted of whole-body immersion excepting the head, whole-body immersion excepting the head and response limb, and immersion of the discrete-response limb. Measures of physiological and behavioural responses were made at sequential .4 degrees C changes during whole-body immersions and approximately 5 degrees C changes of water temperature during the immersion of a limb only. Results suggested that velocity of nerve conduction decreased with thermal depression. Premotor, motor, simple, and choice reaction times varied differentially as a function of the hot and cold conditions. Implications of these differential effects on neuromuscular function are examined with respect to person-machine performance in artificially induced or naturally occurring extremes of ambient temperature.

  6. Cortical organization of inhibition-related functions and modulation by psychopathology

    PubMed Central

    Warren, Stacie L.; Crocker, Laura D.; Spielberg, Jeffery M.; Engels, Anna S.; Banich, Marie T.; Sutton, Bradley P.; Miller, Gregory A.; Heller, Wendy

    2013-01-01

    Individual differences in inhibition-related functions have been implicated as risk factors for a broad range of psychopathology, including anxiety and depression. Delineating neural mechanisms of distinct inhibition-related functions may clarify their role in the development and maintenance of psychopathology. The present study tested the hypothesis that activity in common and distinct brain regions would be associated with an ecologically sensitive, self-report measure of inhibition and a laboratory performance measure of prepotent response inhibition. Results indicated that sub-regions of DLPFC distinguished measures of inhibition, whereas left inferior frontal gyrus and bilateral inferior parietal cortex were associated with both types of inhibition. Additionally, co-occurring anxiety and depression modulated neural activity in select brain regions associated with response inhibition. Results imply that specific combinations of anxiety and depression dimensions are associated with failure to implement top-down attentional control as reflected in inefficient recruitment of posterior DLPFC and increased activation in regions associated with threat (MTG) and worry (BA10). Present findings elucidate possible neural mechanisms of interference that could help explain executive control deficits in psychopathology. PMID:23781192

  7. Cortical organization of inhibition-related functions and modulation by psychopathology.

    PubMed

    Warren, Stacie L; Crocker, Laura D; Spielberg, Jeffery M; Engels, Anna S; Banich, Marie T; Sutton, Bradley P; Miller, Gregory A; Heller, Wendy

    2013-01-01

    Individual differences in inhibition-related functions have been implicated as risk factors for a broad range of psychopathology, including anxiety and depression. Delineating neural mechanisms of distinct inhibition-related functions may clarify their role in the development and maintenance of psychopathology. The present study tested the hypothesis that activity in common and distinct brain regions would be associated with an ecologically sensitive, self-report measure of inhibition and a laboratory performance measure of prepotent response inhibition. Results indicated that sub-regions of DLPFC distinguished measures of inhibition, whereas left inferior frontal gyrus and bilateral inferior parietal cortex were associated with both types of inhibition. Additionally, co-occurring anxiety and depression modulated neural activity in select brain regions associated with response inhibition. Results imply that specific combinations of anxiety and depression dimensions are associated with failure to implement top-down attentional control as reflected in inefficient recruitment of posterior DLPFC and increased activation in regions associated with threat (MTG) and worry (BA10). Present findings elucidate possible neural mechanisms of interference that could help explain executive control deficits in psychopathology.

  8. Filter-fluorescer measurement of low-voltage simulator x-ray energy spectra

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baldwin, G.T.; Craven, R.E.

    X-ray energy spectra of the Maxwell Laboratories MBS and Physics International Pulserad 737 were measured using an eight-channel filter-fluorescer array. The PHOSCAT computer code was used to calculate channel response functions, and the UFO code to unfold spectrum.

  9. 77 FR 53889 - Statement of Organization, Functions, and Delegations of Authority

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-04

    ..., methods, and statistical procedures for assessing and monitoring the health of communities and measuring... methods and the Community Guide, and coordinates division responses to requests for technical assistance...-federal partners in developing indicators, methods, and statistical procedures for measuring and reporting...

  10. 16 CFR 1207.3 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... means members providing structural support to the assembled, installed slide. (5) Casual contact means...) Performance test means a test to measure the functional or structural characteristics of the slide and may... measurements of the slide's response to dynamic and static loads. (20) [Reserved] (21) Pinching hazard means...

  11. Systems for measuring response statistics of gigahertz bandwidth photomultipliers

    NASA Technical Reports Server (NTRS)

    Abshire, J. B.; Rowe, H. E.

    1977-01-01

    New systems have been developed for measuring the average impulse response, the pulse-height spectrum, the transit-time statistics as a function of signal level, and the dark-count spectrum of gigahertz bandwidth photomultipliers. Measurements showed that the 0.53 microns pulse used as an optical test source had a 30 picoseconds and less than 70 ps pulse width. Calibration data showed the system resolution to be less than 20 ps for root mean square transit-time measurements. Test data for a static crossed-field photomultiplier showed 2-photoelectron resolution and less than 30-ps time jitter over the 1- to 100-photoelectron range.

  12. Modeling and characterization of an electromagnetic system for the estimation of Frequency Response Function of spindle

    NASA Astrophysics Data System (ADS)

    Tlalolini, David; Ritou, Mathieu; Rabréau, Clément; Le Loch, Sébastien; Furet, Benoit

    2018-05-01

    The paper presents an electromagnetic system that has been developed to measure the quasi-static and dynamic behavior of machine-tool spindle, at different spindle speeds. This system consists in four Pulse Width Modulation amplifiers and four electromagnets to produce magnetic forces of ± 190 N for the static mode and ± 80 N for the dynamic mode up to 5 kHz. In order to measure the Frequency Response Function (FRF) of spindle, the applied force is required, which is a key issue. A dynamic force model is proposed in order to obtain the load from the measured current in the amplifiers. The model depends on the exciting frequency and on the magnetic characteristics of the system. The predicted force at high speed is validated with a specific experiment and the performance limits of the experimental device are investigated. The FRF obtained with the electromagnetic system is compared to a classical tap test measurement.

  13. Cohort Profile: The Ecuador Life (ECUAVIDA) study in Esmeraldas Province, Ecuador

    PubMed Central

    Cooper, Philip J; Chico, Martha E; Platts-Mills, Thomas AE; Rodrigues, Laura C; Strachan, David P; Barreto, Mauricio L

    2015-01-01

    The ECUAVIDA birth cohort is studying the impact of exposures to soil-transmitted helminth (STH) parasites and early-life microbial exposures on the development of atopy, allergic diseases and immune responses in childhood. A total of 2404 newborns were recruited between 2006 and 2009 in a public hospital serving the rural district of Quininde, Esmeraldas Province, in a tropical region of coastal Ecuador. Detailed measurements were done around the time of the birth, at 7 and 13 months and at 2 and 3 years, and data collection is ongoing at 5 and 8 years. Data being collected include questionnaires for: sociodemographic, lifestyle, psychosocial (at 4–6 years only) and dietary (at 6–7 years only) factors; childhood morbidity and clinical outcomes; stool samples for parasites; blood samples for DNA, measurements of vaccine responses and other measures of immune function/inflammation; and anthropometrics. Allergen skin prick test reactivity is done from 2 years and measures of airway function and inflammation at 8 years. PMID:24990475

  14. Development of a real-time transport performance optimization methodology

    NASA Technical Reports Server (NTRS)

    Gilyard, Glenn

    1996-01-01

    The practical application of real-time performance optimization is addressed (using a wide-body transport simulation) based on real-time measurements and calculation of incremental drag from forced response maneuvers. Various controller combinations can be envisioned although this study used symmetric outboard aileron and stabilizer. The approach is based on navigation instrumentation and other measurements found on state-of-the-art transports. This information is used to calculate winds and angle of attack. Thrust is estimated from a representative engine model as a function of measured variables. The lift and drag equations are then used to calculate lift and drag coefficients. An expression for drag coefficient, which is a function of parasite drag, induced drag, and aileron drag, is solved from forced excitation response data. Estimates of the parasite drag, curvature of the aileron drag variation, and minimum drag aileron position are produced. Minimum drag is then obtained by repositioning the symmetric aileron. Simulation results are also presented which evaluate the affects of measurement bias and resolution.

  15. Signal pulse emulation for scintillation detectors using Geant4 Monte Carlo with light tracking simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ogawara, R.; Ishikawa, M., E-mail: masayori@med.hokudai.ac.jp

    The anode pulse of a photomultiplier tube (PMT) coupled with a scintillator is used for pulse shape discrimination (PSD) analysis. We have developed a novel emulation technique for the PMT anode pulse based on optical photon transport and a PMT response function. The photon transport was calculated using Geant4 Monte Carlo code and the response function with a BC408 organic scintillator. The obtained percentage RMS value of the difference between the measured and simulated pulse with suitable scintillation properties using GSO:Ce (0.4, 1.0, 1.5 mol%), LaBr{sub 3}:Ce and BGO scintillators were 2.41%, 2.58%, 2.16%, 2.01%, and 3.32%, respectively. The proposedmore » technique demonstrates high reproducibility of the measured pulse and can be applied to simulation studies of various radiation measurements.« less

  16. Millimeter-wave monolithic integrated circuit characterization by a picosecond optoelectronic technique

    NASA Astrophysics Data System (ADS)

    Hung, Hing-Loi A.; Smith, Thane; Huang, Ho C.; Polak-Dingels, Penny; Webb, Kevin J.

    1989-08-01

    The characterization of microwave and millimeter-wave monolithic integrated circits (MIMICs) using picosecond pulse-sampling techniques is developed with emphasis on improving broadband coverage and measurement accuracy. GaAs photoconductive swithces are used for signal generation and sampling operations. The measured time-domain response allows the spectral transfer function of the MIMIC to be obtained. This measurement technique is verified by characterization of the frequency response (magnitude and phase) of a reference 50-ohm microstrip line and a two-stage Ka-band MIMIC amplifier. The measured broadband results agree with those obtained from conventional frequency-domain measurements using a network analyzer. The application of this optical technique to on-wafer MIMIC characterization is described.

  17. Response of a tissue equivalent proportional counter to neutrons

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; Robbins, D. E.; Gibbons, F.; Braby, L. A.

    2002-01-01

    The absorbed dose as a function of lineal energy was measured at the CERN-EC Reference-field Facility (CERF) using a 512-channel tissue equivalent proportional counter (TEPC), and neutron dose equivalent response evaluated. Although there are some differences, the measured dose equivalent is in agreement with that measured by the 16-channel HANDI tissue equivalent counter. Comparison of TEPC measurements with those made by a silicon solid-state detector for low linear energy transfer particles produced by the same beam, is presented. The measurements show that about 4% of dose equivalent is delivered by particles heavier than protons generated in the conducting tissue equivalent plastic. c2002 Elsevier Science Ltd. All rights reserved.

  18. Functional Limitations of Vocational Rehabilitation (VR) Consumers Final Report

    ERIC Educational Resources Information Center

    Overman, Beth; Schmidt-Davis, Holly

    2006-01-01

    In response to a request from the Rehabilitation Services Administration (RSA), the Research Triangle Institute (RTI) conducted a study to examine the feasibility of developing functional status measures for planning and implementing services to consumers in the State-Federal Vocational Rehabilitation (VR) Services Program. To investigate this…

  19. Measuring Dynamic Kidney Function in an Undergraduate Physiology Laboratory

    ERIC Educational Resources Information Center

    Medler, Scott; Harrington, Frederick

    2013-01-01

    Most undergraduate physiology laboratories are very limited in how they treat renal physiology. It is common to find teaching laboratories equipped with the capability for high-resolution digital recordings of physiological functions (muscle twitches, ECG, action potentials, respiratory responses, etc.), but most urinary laboratories still rely on…

  20. Pressure dependence of the electro-optic response function in partially exposed polymer dispersed ferroelectric liquid crystals

    NASA Technical Reports Server (NTRS)

    Parmar, D. S.; Holmes, H. K.

    1993-01-01

    Ferroelectric liquid crystals in a new configuration, termed partially exposed polymer dispersed ferroelectric liquid crystal (PEPDFLC), respond to external pressures and demonstrate pressure-induced electro-optic switching response. When the PEPDFLC thin film is sandwiched between two transparent conducting electrodes, one a glass plate and the other a flexible sheet such as polyvenylidene fluoride, the switching characteristics of the thin film are a function of the pressure applied to the flexible transparent electrode and the bias voltage across the electrodes. Response time measurements reveal a linear dependence of the change in electric field with external pressure.

  1. Electromagnetic response of C 12 : A first-principles calculation

    DOE PAGES

    Lovato, A.; Gandolfi, S.; Carlson, J.; ...

    2016-08-15

    Here, the longitudinal and transverse electromagnetic response functions ofmore » $$^{12}$$C are computed in a ``first-principles'' Green's function Monte Carlo calculation, based on realistic two- and three-nucleon interactions and associated one- and two-body currents. We find excellent agreement between theory and experiment and, in particular, no evidence for the quenching of measured versus calculated longitudinal response. This is further corroborated by a re-analysis of the Coulomb sum rule, in which the contributions from the low-lying $$J^\\pi\\,$$=$$\\, 2^+$$, $0^+$ (Hoyle), and $4^+$ states in $$^{12}$$C are accounted for explicitly in evaluating the total inelastic strength.« less

  2. Steady-State Contrast Response Functions Provide a Sensitive and Objective Index of Amblyopic Deficits

    PubMed Central

    Baker, Daniel H.; Simard, Mathieu; Saint-Amour, Dave; Hess, Robert F.

    2015-01-01

    Purpose. Visual deficits in amblyopia are neural in origin, yet are difficult to characterize with functional magnetic resonance imagery (fMRI). Our aim was to develop an objective electroencephalography (EEG) paradigm that can be used to provide a clinically useful index of amblyopic deficits. Methods. We used steady-state visual evoked potentials (SSVEPs) to measure full contrast response functions in both amblyopic (n = 10, strabismic or mixed amblyopia, mean age: 44 years) and control (n = 5, mean age: 31 years) observers, both with and without a dichoptic mask. Results. At the highest target contrast, the ratio of amplitudes across the weaker and stronger eyes was highly correlated (r = 0.76) with the acuity ratio between the eyes. We also found that the contrast response function in the amblyopic eye had both a greatly reduced amplitude and a shallower slope, but that surprisingly dichoptic masking was weaker than in controls. The results were compared with the predictions of a computational model of amblyopia and suggest a modification to the model whereby excitatory (but not suppressive) signals are attenuated in the amblyopic eye. Conclusions. We suggest that SSVEPs offer a sensitive and objective measure of the ocular imbalance in amblyopia and could be used to assess the efficacy of amblyopia therapies currently under development. PMID:25634977

  3. Scale-Dependence of Processes Structuring Dung Beetle Metacommunities Using Functional Diversity and Community Deconstruction Approaches

    PubMed Central

    da Silva, Pedro Giovâni; Hernández, Malva Isabel Medina

    2015-01-01

    Community structure is driven by mechanisms linked to environmental, spatial and temporal processes, which have been successfully addressed using metacommunity framework. The relative importance of processes shaping community structure can be identified using several different approaches. Two approaches that are increasingly being used are functional diversity and community deconstruction. Functional diversity is measured using various indices that incorporate distinct community attributes. Community deconstruction is a way to disentangle species responses to ecological processes by grouping species with similar traits. We used these two approaches to determine whether they are improvements over traditional measures (e.g., species composition, abundance, biomass) for identification of the main processes driving dung beetle (Scarabaeinae) community structure in a fragmented mainland-island landscape in southern Brazilian Atlantic Forest. We sampled five sites in each of four large forest areas, two on the mainland and two on the island. Sampling was performed in 2012 and 2013. We collected abundance and biomass data from 100 sampling points distributed over 20 sampling sites. We studied environmental, spatial and temporal effects on dung beetle community across three spatial scales, i.e., between sites, between areas and mainland-island. The γ-diversity based on species abundance was mainly attributed to β-diversity as a consequence of the increase in mean α- and β-diversity between areas. Variation partitioning on abundance, biomass and functional diversity showed scale-dependence of processes structuring dung beetle metacommunities. We identified two major groups of responses among 17 functional groups. In general, environmental filters were important at both local and regional scales. Spatial factors were important at the intermediate scale. Our study supports the notion of scale-dependence of environmental, spatial and temporal processes in the distribution and functional organization of Scarabaeinae beetles. We conclude that functional diversity may be used as a complementary approach to traditional measures, and that community deconstruction allows sufficient disentangling of responses of different trait-based groups. PMID:25822150

  4. Toward a loss of functional diversity in stream fish assemblages under climate change.

    PubMed

    Buisson, Laëtitia; Grenouillet, Gaël; Villéger, Sébastien; Canal, Julie; Laffaille, Pascal

    2013-02-01

    The assessment of climate change impacts on biodiversity has so far been biased toward the taxonomic identification of the species likely either to benefit from climate modifications or to experience overall declines. There have still been few studies intended to correlate the characteristics of species to their sensitivity to climate change, even though it is now recognized that functional trait-based approaches are promising tools for addressing challenges related to global changes. In this study, two functional indices (originality and uniqueness) were first measured for 35 fish species occurring in French streams. They were then combined to projections of range shifts in response to climate change derived from species distribution models. We set out to investigate: (1) the relationship between the degrees of originality and uniqueness of fish species, and their projected response to future climate change; and (2) the consequences of individual responses of species for the functional diversity of fish assemblages. After accounting for phylogenetic relatedness among species, we have demonstrated that the two indices used measure two complementary facets of the position of fish species in a functional space. We have also rejected the hypothesis that the most original and/or less redundant species would necessarily experience the greatest declines in habitat suitability as a result of climate change. However, individual species range shifts could lead simultaneously both to a severe decline in the functional diversity of fish assemblages, and to an increase in the functional similarity among assemblages, supporting the hypothesis that disturbance favors communities with combination of common traits and biotic homogenization as well. Our findings therefore emphasize the importance of going beyond the simple taxonomic description of diversity to provide a better assessment of the likely future effects of environmental changes on biodiversity, thus helping to design more effective conservation and management measures. © 2012 Blackwell Publishing Ltd.

  5. The PROMIS Physical Function item bank was calibrated to a standardized metric and shown to improve measurement efficiency.

    PubMed

    Rose, Matthias; Bjorner, Jakob B; Gandek, Barbara; Bruce, Bonnie; Fries, James F; Ware, John E

    2014-05-01

    To document the development and psychometric evaluation of the Patient-Reported Outcomes Measurement Information System (PROMIS) Physical Function (PF) item bank and static instruments. The items were evaluated using qualitative and quantitative methods. A total of 16,065 adults answered item subsets (n>2,200/item) on the Internet, with oversampling of the chronically ill. Classical test and item response theory methods were used to evaluate 149 PROMIS PF items plus 10 Short Form-36 and 20 Health Assessment Questionnaire-Disability Index items. A graded response model was used to estimate item parameters, which were normed to a mean of 50 (standard deviation [SD]=10) in a US general population sample. The final bank consists of 124 PROMIS items covering upper, central, and lower extremity functions and instrumental activities of daily living. In simulations, a 10-item computerized adaptive test (CAT) eliminated floor and decreased ceiling effects, achieving higher measurement precision than any comparable length static tool across four SDs of the measurement range. Improved psychometric properties were transferred to the CAT's superior ability to identify differences between age and disease groups. The item bank provides a common metric and can improve the measurement of PF by facilitating the standardization of patient-reported outcome measures and implementation of CATs for more efficient PF assessments over a larger range. Copyright © 2014. Published by Elsevier Inc.

  6. Roland-Morris Disability Questionnaire and Oswestry Disability Index: Which Has Better Measurement Properties for Measuring Physical Functioning in Nonspecific Low Back Pain? Systematic Review and Meta-Analysis.

    PubMed

    Chiarotto, Alessandro; Maxwell, Lara J; Terwee, Caroline B; Wells, George A; Tugwell, Peter; Ostelo, Raymond W

    2016-10-01

    Physical functioning is a core outcome domain to be measured in nonspecific low back pain (NSLBP). A panel of experts recommended the Roland-Morris Disability Questionnaire (RMDQ) and Oswestry Disability Index (ODI) to measure this domain. The original 24-item RMDQ and ODI 2.1a are recommended by their developers. The purpose of this study was to evaluate whether the 24-item RMDQ or the ODI 2.1a has better measurement properties than the other to measure physical functioning in adult patients with NSLBP. Bibliographic databases (MEDLINE, Embase, CINAHL, SportDiscus, PsycINFO, and Google Scholar), references of existing reviews, and citation tracking were the data sources. Two reviewers selected studies performing a head-to-head comparison of measurement properties (reliability, validity, and responsiveness) of the 2 questionnaires. The COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist was used to assess the methodological quality of these studies. The studies' characteristics and results were extracted by 2 reviewers. A meta-analysis was conducted when there was sufficient clinical and methodological homogeneity among studies. Nine articles were included, for a total of 11 studies assessing 5 measurement properties. All studies were classified as having poor or fair methodological quality. The ODI displayed better test-retest reliability and smaller measurement error, whereas the RMDQ presented better construct validity as a measure of physical functioning. There was conflicting evidence for both instruments regarding responsiveness and inconclusive evidence for internal consistency. The results of this review are not generalizable to all available versions of these questionnaires or to patients with specific causes for their LBP. Based on existing head-to-head comparison studies, there are no strong reasons to prefer 1 of these 2 instruments to measure physical functioning in patients with NSLBP, but studies of higher quality are needed to confirm this conclusion. Foremost, content, structural, and cross-cultural validity of these questionnaires in patients with NSLBP should be assessed and compared. © 2016 American Physical Therapy Association.

  7. Development of the Barkin Index of Maternal Functioning.

    PubMed

    Barkin, Jennifer L; Wisner, Katherine L; Bromberger, Joyce T; Beach, Scott R; Terry, Martha A; Wisniewski, Stephen R

    2010-12-01

    Maternal functional status is important to capture in the 12 months after childbirth, as this period marks a critical window for both mother and child. In most cases, mothers are the primary caregivers and are, therefore, responsible for the majority of the work related to infant care tasks, such as feeding, diaper changes, and doctor's appointments. Additionally, the quality of mother-child interaction in the year after childbirth affects child development. To date, postpartum functioning has exacted scarce coverage, with only one instrument claiming to measure the concept explicitly. This necessitated the development of the Barkin Index of Maternal Functioning (BIMF), which was designed to measure functioning in the year after childbirth. Three focus groups comprised of 31 new mothers were held to elicit women's concept of functioning in the first postpartum year. Women were asked to discuss the responsibilities associated with new motherhood as well as the circumstances surrounding high and low functioning periods. The qualitative data produced by the focus groups were coded by emotive tone and content and translated into item construction for the BIMF, a 20-item self-report measure of functioning intended for use in the year after childbirth. Before implementation into the screening study, the BIMF was critiqued by a panel of experts and cross-checked with the literature to ensure that no major contextual domains were absent. Psychometric testing revealed adequate internal reliability and construct validity, and the BIMF has been implemented successfully in clinical settings. The high level of patient engagement and psychometric properties associated with the BIMF are indicative of its potential to become a valuable tool for assessing maternal wellness.

  8. Rasch analysis of the Italian Lower Extremity Functional Scale: insights on dimensionality and suggestions for an improved 15-item version.

    PubMed

    Bravini, Elisabetta; Giordano, Andrea; Sartorio, Francesco; Ferriero, Giorgio; Vercelli, Stefano

    2017-04-01

    To investigate dimensionality and the measurement properties of the Italian Lower Extremity Functional Scale using both classical test theory and Rasch analysis methods, and to provide insights for an improved version of the questionnaire. Rasch analysis of individual patient data. Rehabilitation centre. A total of 135 patients with musculoskeletal diseases of the lower limb. Patients were assessed with the Lower Extremity Functional Scale before and after the rehabilitation. Rasch analysis showed some problems related to rating scale category functioning, items fit, and items redundancy. After an iterative process, which resulted in the reduction of rating scale categories from 5 to 4, and in the deletion of 5 items, the psychometric properties of the Italian Lower Extremity Functional Scale improved. The retained 15 items with a 4-level response format fitted the Rasch model (internal construct validity), and demonstrated unidimensionality and good reliability indices (person-separation reliability 0.92; Cronbach's alpha 0.94). Then, the analysis showed differential item functioning for six of the retained items. The sensitivity to change of the Italian 15-item Lower Extremity Functional Scale was nearly equal to the one of the original version (effect size: 0.93 and 0.98; standardized response mean: 1.20 and 1.28, respectively for the 15-item and 20-item versions). The Italian Lower Extremity Functional Scale had unsatisfactory measurement properties. However, removing five items and simplifying the scoring from 5 to 4 levels resulted in a more valid measure with good reliability and sensitivity to change.

  9. Self-contained, low-cost Body-on-a-Chip systems for drug development.

    PubMed

    Wang, Ying I; Oleaga, Carlota; Long, Christopher J; Esch, Mandy B; McAleer, Christopher W; Miller, Paula G; Hickman, James J; Shuler, Michael L

    2017-11-01

    Integrated multi-organ microphysiological systems are an evolving tool for preclinical evaluation of the potential toxicity and efficacy of drug candidates. Such systems, also known as Body-on-a-Chip devices, have a great potential to increase the successful conversion of drug candidates entering clinical trials into approved drugs. Systems, to be attractive for commercial adoption, need to be inexpensive, easy to operate, and give reproducible results. Further, the ability to measure functional responses, such as electrical activity, force generation, and barrier integrity of organ surrogates, enhances the ability to monitor response to drugs. The ability to operate a system for significant periods of time (up to 28 d) will provide potential to estimate chronic as well as acute responses of the human body. Here we review progress towards a self-contained low-cost microphysiological system with functional measurements of physiological responses. Impact statement Multi-organ microphysiological systems are promising devices to improve the drug development process. The development of a pumpless system represents the ability to build multi-organ systems that are of low cost, high reliability, and self-contained. These features, coupled with the ability to measure electrical and mechanical response in addition to chemical or metabolic changes, provides an attractive system for incorporation into the drug development process. This will be the most complete review of the pumpless platform with recirculation yet written.

  10. Measurement of Residual Flexibility for Substructures Having Prominent Flexible Interfaces

    NASA Technical Reports Server (NTRS)

    Tinker, Michael L.; Bookout, Paul S.

    1994-01-01

    Verification of a dynamic model of a constrained structure requires a modal survey test of the physical structure and subsequent modification of the model to obtain the best agreement possible with test data. Constrained-boundary or fixed-base testing has historically been the most common approach for verifying constrained mathematical models, since the boundary conditions of the test article are designed to match the actual constraints in service. However, there are difficulties involved with fixed-base testing, in some cases making the approach impractical. It is not possible to conduct a truly fixed-base test due to coupling between the test article and the fixture. In addition, it is often difficult to accurately simulate the actual boundary constraints, and the cost of designing and constructing the fixture may be prohibitive. For use when fixed-base testing proves impractical or undesirable, alternate free-boundary test methods have been investigated, including the residual flexibility technique. The residual flexibility approach has been treated analytically in considerable detail and has had limited frequency response measurements for the method. This concern is well-justified for a number of reasons. First, residual flexibilities are very small numbers, typically on the order of 1.0E-6 in/lb for translational diagonal terms, and orders of magnitude smaller for off-diagonal values. This poses difficulty in obtaining accurate and noise-free measurements, especially for points removed from the excitation source. A second difficulty encountered in residual measurements lies in obtaining a clean residual function in the process of subtracting synthesized modal data from a measured response function. Inaccuracies occur since modes are not subtracted exactly, but only to the accuracy of the curve fits for each mode; these errors are compounded with increasing distance from the excitation point. In this paper, the residual flexibility method is applied to a simple structure in both test and analysis. Measured and predicted residual functions are compared, and regions of poor data in the measured curves are described. It is found that for accurate residual measurements, frequency response functions having prominent stiffness lines in the acceleration/force format are needed. The lack of such stiffness lines increases measurement errors. Interface drive point frequency respose functions for shuttle orbiter payloads exhibit dominant stiffness lines, making the residual test approach a good candidate for payload modal tests when constrained tests are inappropriate. Difficulties in extracting a residual flexibility value from noisy test data are discussed. It is shown that use of a weighted second order least-squares curve fit of the measured residual function allows identification of residual flexibility that compares very well with predictions for the simple structure. This approach also provides an estimate of second order residual mass effects.

  11. Photocatalytic Active Radiation Measurements and Use

    NASA Technical Reports Server (NTRS)

    Davis, Bruce A.; Underwood, Lauren W.

    2011-01-01

    Photocatalytic materials are being used to purify air, to kill microbes, and to keep surfaces clean. A wide variety of materials are being developed, many of which have different abilities to absorb various wavelengths of light. Material variability, combined with both spectral illumination intensity and spectral distribution variability, will produce a wide range of performance results. The proposed technology estimates photocatalytic active radiation (PcAR), a unit of radiation that normalizes the amount of light based on its spectral distribution and on the ability of the material to absorb that radiation. Photocatalytic reactions depend upon the number of electron-hole pairs generated at the photocatalytic surface. The number of electron-hole pairs produced depends on the number of photons per unit area per second striking the surface that can be absorbed and whose energy exceeds the bandgap of the photocatalytic material. A convenient parameter to describe the number of useful photons is the number of moles of photons striking the surface per unit area per second. The unit of micro-einsteins (or micromoles) of photons per m2 per sec is commonly used for photochemical and photoelectric-like phenomena. This type of parameter is used in photochemistry, such as in the conversion of light energy for photosynthesis. Photosynthetic response correlates with the number of photons rather than by energy because, in this photochemical process, each molecule is activated by the absorption of one photon. In photosynthesis, the number of photons absorbed in the 400 700 nm spectral range is estimated and is referred to as photosynthetic active radiation (PAR). PAR is defined in terms of the photosynthetic photon flux density measured in micro-einsteins of photons per m2 per sec. PcAR is an equivalent, similarly modeled parameter that has been defined for the photocatalytic processes. Two methods to measure the PcAR level are being proposed. In the first method, a calibrated spectrometer with a cosine receptor is used to measure the spectral irradiance. This measurement, in conjunction with the photocatalytic response as a function of wavelength, is used to estimate the PcAR. The photocatalytic response function is determined by measuring photocatalytic reactivity as a function of wavelength. In the second method, simple shaped photocatalytic response functions can be simulated with a broad-band detector with a cosine receptor appropriately filtered to represent the spectral response of the photocatalytic material. This second method can be less expensive than using a calibrated spectrometer.

  12. Childhood Parental Loss and Adult Hypothalamic-Pituitary-Adrenal Function

    PubMed Central

    Tyrka, Audrey R.; Wier, Lauren; Price, Lawrence H.; Ross, Nicole; Anderson, George M.; Wilkinson, Charles W.; Carpenter, Linda L.

    2009-01-01

    Background Several decades of research link childhood parental loss with risk for major depression and other forms of psychopathology. A large body of preclinical work on maternal separation and some recent studies of humans with childhood parental loss have demonstrated alterations of hypothalamic-pituitary-adrenal (HPA) axis function which could predispose to the development of psychiatric disorders. Methods Eighty-eight healthy adults with no current Axis I psychiatric disorder participated in this study. Forty-four participants experienced parental loss during childhood, including 19 with a history of parental death and 25 with a history of prolonged parental separation. The loss group was compared to a matched group of individuals who reported no history of childhood parental separation or childhood maltreatment. Participants completed diagnostic interviews and questionnaires and the dexamethasone/corticotropin-releasing hormone (Dex/CRH) test. Repeated measures general linear models were used to test the effects of parental loss, a measure of parental care, sex, and age on the hormone responses to the Dex/CRH test. Results Parental loss was associated with increased cortisol responses to the test, particularly in males. The effect of loss was moderated by levels of parental care; participants with parental desertion and very low levels of care had attenuated cortisol responses. ACTH responses to the Dex/CRH test did not differ significantly as a function of parental loss. Conclusions These findings are consistent with the hypothesis that early parental loss induces enduring changes in neuroendocrine function. PMID:18339361

  13. An Accuracy--Response Time Capacity Assessment Function that Measures Performance against Standard Parallel Predictions

    ERIC Educational Resources Information Center

    Townsend, James T.; Altieri, Nicholas

    2012-01-01

    Measures of human efficiency under increases in mental workload or attentional limitations are vital in studying human perception, cognition, and action. Assays of efficiency as workload changes have typically been confined to either reaction times (RTs) or accuracy alone. Within the realm of RTs, a nonparametric measure called the "workload…

  14. A Case Example of Assessment and Evaluation: Building Capability in a Corporate University

    ERIC Educational Resources Information Center

    Overcast, Shawn; Schmidt, Therese; Lei, Kimfong; Rodgers, Carrie; Chung, Nigel A.

    2009-01-01

    One corporate university makes measurement a priority by dedicating resources and assigning responsibilities to a centralized analytics function: the assessment, measurement, and evaluation team. As more measurement became a focus for learning and business leaders alike, the more the team became motivated to take a critical look at how it was…

  15. The energy dependence of the lateral dose response functions of detectors with various densities in photon-beam dosimetry.

    PubMed

    Looe, Hui Khee; Harder, Dietrich; Poppe, Björn

    2017-02-07

    The lateral dose response function is a general characteristic of the volume effect of a detector used for photon dosimetry in a water phantom. It serves as the convolution kernel transforming the true absorbed dose to water profile, which would be produced within the undisturbed water phantom, into the detector-measured signal profile. The shape of the lateral dose response function characterizes (i) the volume averaging attributable to the detector's size and (ii) the disturbance of the secondary electron field associated with the deviation of the electron density of the detector material from the surrounding water. In previous work, the characteristic dependence of the shape of the lateral dose response function upon the electron density of the detector material was studied for 6 MV photons by Monte Carlo simulation of a wall-less voxel-sized detector (Looe et al 2015 Phys. Med. Biol. 60 6585-07). This study is here continued for 60 Co gamma rays and 15 MV photons in comparison with 6 MV photons. It is found (1) that throughout these photon spectra the shapes of the lateral dose response functions are retaining their characteristic dependence on the detector's electron density, and (2) that their energy-dependent changes are only moderate. This appears as a practical advantage because the lateral dose response function can then be treated as practically invariant across a clinical photon beam in spite of the known changes of the photon spectrum with increasing distance from the beam axis.

  16. Development and psychometric validation of a child Racial Attitudes Index (RAI).

    PubMed

    Clark, Khaya D; Yovanoff, Paul; Tate, Charlotte Ursula

    2017-12-01

    The Racial Attitudes Index (RAI) measures a child's racial attitudes. Designed for children aged 5-9 years, the RAI is delivered over the Internet using Audio Computer Assisted Self-Interviewing (ACASI). Unlike traditional binary forced-choice instruments, the RAI uses an expanded response format permitting a more nuanced understanding of patterns of children's racial attitudes. In addition to establishing psychometric evidence of the RAI technical adequacy, hypotheses about RAI item response patterns were tested. The racial attitudes of 336 Black and White children in grades K-3 were assessed using a forced-choice instrument (Preschool Racial Attitudes Measure II) and the RAI. Findings from this study indicate measures obtained with the RAI are technically adequate, and the measure functions invariantly across racial groups. Also, patterns of children's racial attitudes measured with the RAI are more nuanced than those obtained using the forced-choice response format.

  17. Voltage transfer function as an optical method to characterize electrical properties of liquid crystal devices.

    PubMed

    Bateman, J; Proctor, M; Buchnev, O; Podoliak, N; D'Alessandro, G; Kaczmarek, M

    2014-07-01

    The voltage transfer function is a rapid and visually effective method to determine the electrical response of liquid crystal (LC) systems using optical measurements. This method relies on crosspolarized intensity measurements as a function of the frequency and amplitude of the voltage applied to the device. Coupled with a mathematical model of the device it can be used to determine the device time constants and electrical properties. We validate the method using photorefractive LC cells and determine the main time constants and the voltage dropped across the layers using a simple nonlinear filter model.

  18. Variability of non-response to aspirin in patients with peripheral arterial occlusive disease during long-term follow-up.

    PubMed

    Linnemann, Birgit; Prochnow, Stephanie; Mani, Helen; Schwonberg, Jan; Lindhoff-Last, Edelgard

    2009-10-01

    Non-responsiveness to aspirin as detected by laboratory tests may identify patients at high risk for future vascular events. The aim of this prospective study was to evaluate whether non-responsiveness to aspirin is stable over time. Ninety-eight patients with stable peripheral arterial occlusive disease (PAOD) treated with 100 mg/d aspirin were followed over a median timeframe of 17 months. Platelet function tests were performed initially and at follow-up using arachidonic acid-induced light transmittance aggregometry (LTA) in native platelet-rich plasma with the Behring Coagulation Timer and by measuring the collagen-epinephrine closure time (CT) on a Platelet Function Analyzer (PFA-100). When determining platelet function using LTA, four patients (4.1%) had residual platelet function (i.e., MaxAggr > or =78%) despite aspirin treatment, whereas, according to the PFA-100 results, 12 patients (12.2%) were identified as non-responders (i.e., CT <192 s). Fifty-seven patients who were still under treatment with 100 mg/d aspirin at the time of follow-up provided a second blood sample. Further platelet function tests with the PFA-100 system identified a persistent non-responsiveness to aspirin over time in three patients (5.3%) whereas four (7.0%) and 15 (26.3%) patients had changes in response status when platelet function was assessed by LTA and on the PFA-100(R), respectively. We conclude that true non-responsiveness to aspirin is a rare phenomenon in stable PAOD patients. Furthermore, we conclude that in a number of patients, aspirin non-responsiveness is not stable over time.

  19. The impact of executive function on response to cognitive behavioral therapy in late-life depression.

    PubMed

    Goodkind, Madeleine S; Gallagher-Thompson, Dolores; Thompson, Larry W; Kesler, Shelli R; Anker, Lauren; Flournoy, John; Berman, Mika P; Holland, Jason M; O'Hara, Ruth M

    2016-04-01

    Late-life depression (LLD) is a common and debilitating condition among older adults. Cognitive behavioral therapy (CBT) has strong empirical support for the treatment of depression in all ages, including in LLD. In teaching patients to identify, monitor, and challenge negative patterns in their thinking, CBT for LLD relies heavily on cognitive processes and, in particular, executive functioning, such as planning, sequencing, organizing, and selectively inhibiting information. It may be that the effectiveness of CBT lies in its ability to train these cognitive areas. Participants with LLD completed a comprehensive neuropsychological battery before enrolling in CBT. The current study examined the relationship between neuropsychological function prior to treatment and response to CBT. When using three baseline measures of executive functioning that quantify set shifting, cognitive flexibility, and response inhibition to predict treatment response, only baseline Wisconsin Card Sort Task performance was associated with a significant drop in depression symptoms after CBT. Specifically, worse performance on the Wisconsin Card Sort Task was associated with better treatment response. These results suggest that CBT, which teaches cognitive techniques for improving psychiatric symptoms, may be especially beneficial in LLD if relative weaknesses in specific areas of executive functioning are present. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Tapered Optical Fiber Functionalized with Palladium Nanoparticles by Drop Casting and Laser Radiation for H2 and Volatile Organic Compounds Sensing Purposes

    PubMed Central

    González-Sierra, Nancy Elizabeth; Gómez-Pavón, Luz del Carmen; Pérez-Sánchez, Gerardo Francisco; Luis-Ramos, Arnulfo; Zaca-Morán, Plácido; Chávez-Ramírez, Fernando

    2017-01-01

    A comparative study on the sensing properties of a tapered optical fiber pristine and functionalized with the palladium nanoparticles to hydrogen and volatile organic compounds (VOCs), is presented. The sensor response and, response/recovery times were extracted from the measurements of the transient response of the device. The tapered optical fiber sensor was fabricated using a single-mode optical fiber by the flame-brushing technique. Functionalization of the optical fiber was performed using an aqueous solution of palladium chloride by drop-casting technique assisted for laser radiation. The detection principle of the sensor is based on the changes in the optical properties of palladium nanoparticles when exposed to reducing gases, which causes a variation in the absorption of evanescent waves. A continuous wave laser diode operating at 1550 nm is used for the sensor characterization. The sensor functionalized with palladium nanoparticles by this technique is viable for the sensing of hydrogen and VOCs, since it shows an enhancement in sensor response and response time compared to the sensor based on the pristine optical microfiber. The results show that the fabricated sensor is competitive with other fiber optic sensors functionalized with palladium nanoparticles to the hydrogen. PMID:28878161

  1. The Richness of Task-Evoked Hemodynamic Responses Defines a Pseudohierarchy of Functionally Meaningful Brain Networks

    PubMed Central

    Orban, Pierre; Doyon, Julien; Petrides, Michael; Mennes, Maarten; Hoge, Richard; Bellec, Pierre

    2015-01-01

    Functional magnetic resonance imaging can measure distributed and subtle variations in brain responses associated with task performance. However, it is unclear whether the rich variety of responses observed across the brain is functionally meaningful and consistent across individuals. Here, we used a multivariate clustering approach that grouped brain regions into clusters based on the similarity of their task-evoked temporal responses at the individual level, and then established the spatial consistency of these individual clusters at the group level. We observed a stable pseudohierarchy of task-evoked networks in the context of a delayed sequential motor task, where the fractionation of networks was driven by a gradient of involvement in motor sequence preparation versus execution. In line with theories about higher-level cognitive functioning, this gradient evolved in a rostro-caudal manner in the frontal lobe. In addition, parcellations in the cerebellum and basal ganglia matched with known anatomical territories and fiber pathways with the cerebral cortex. These findings demonstrate that subtle variations in brain responses associated with task performance are systematic enough across subjects to define a pseudohierarchy of task-evoked networks. Such networks capture meaningful functional features of brain organization as shaped by a given cognitive context. PMID:24729172

  2. Tapered Optical Fiber Functionalized with Palladium Nanoparticles by Drop Casting and Laser Radiation for H₂ and Volatile Organic Compounds Sensing Purposes.

    PubMed

    González-Sierra, Nancy Elizabeth; Gómez-Pavón, Luz Del Carmen; Pérez-Sánchez, Gerardo Francisco; Luis-Ramos, Arnulfo; Zaca-Morán, Plácido; Muñoz-Pacheco, Jesús Manuel; Chávez-Ramírez, Francisco

    2017-09-06

    A comparative study on the sensing properties of a tapered optical fiber pristine and functionalized with the palladium nanoparticles to hydrogen and volatile organic compounds (VOCs), is presented. The sensor response and, response/recovery times were extracted from the measurements of the transient response of the device. The tapered optical fiber sensor was fabricated using a single-mode optical fiber by the flame-brushing technique. Functionalization of the optical fiber was performed using an aqueous solution of palladium chloride by drop-casting technique assisted for laser radiation. The detection principle of the sensor is based on the changes in the optical properties of palladium nanoparticles when exposed to reducing gases, which causes a variation in the absorption of evanescent waves. A continuous wave laser diode operating at 1550 nm is used for the sensor characterization. The sensor functionalized with palladium nanoparticles by this technique is viable for the sensing of hydrogen and VOCs, since it shows an enhancement in sensor response and response time compared to the sensor based on the pristine optical microfiber. The results show that the fabricated sensor is competitive with other fiber optic sensors functionalized with palladium nanoparticles to the hydrogen.

  3. Increased sensory noise and not muscle weakness explains changes in non-stepping postural responses following stance perturbations in healthy elderly.

    PubMed

    Afschrift, Maarten; De Groote, Friedl; Verschueren, Sabine; Jonkers, Ilse

    2018-01-01

    The response to stance perturbations changes with age. The shift from an ankle to a hip strategy with increasing perturbation magnitude occurs at lower accelerations in older than in young adults. This strategy shift has been related to age-related changes in muscle and sensory function. However, the effect of isolated changes in muscle or sensory function on the responses following stance perturbations cannot be determined experimentally since changes in muscle and sensory function occur simultaneously. Therefore, we used predictive simulations to estimate the effect of isolated changes in (rates of change in) maximal joint torques, functional base of support, and sensory noise on the response to backward platform translations. To evaluate whether these modeled changes in muscle and sensory function could explain the observed changes in strategy; simulated postural responses with a torque-driven double inverted pendulum model controlled using optimal state feedback were compared to measured postural responses in ten healthy young and ten healthy older adults. The experimentally observed peak hip angle during the response was significantly larger (5°) and the functional base of support was smaller (0.04m) in the older than in the young adults but peak joint torques and rates of joint torque were similar during the recovery. The addition of noise to the sensed states in the predictive simulations could explain the observed increase in peak hip angle in the elderly, whereas changes in muscle function could not. Hence, our results suggest that strength training alone might be insufficient to improve postural control in elderly. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Time-dependent compressibility of poly (methyl methacrylate) (PMMA) : an experimental and molecular dynamics investigation

    NASA Astrophysics Data System (ADS)

    Sane, Sandeep Bhalchandra

    This thesis contains three chapters, which describe different aspects of an investigation of the bulk response of Poly(Methyl Methacrylate) (PMMA). The first chapter describes the physical measurements by means of a Belcher/McKinney-type apparatus. Used earlier for the measurement of the bulk response of Poly(Vinyl Acetate), it was now adapted for making measurements at higher temperatures commensurate with the glass transition temperature of PMMA. The dynamic bulk compliance of PMMA was measured at atmospheric pressure over a wide range of temperatures and frequencies, from which the master curves for the bulk compliance were generated by means of the time-temperature superposition principle. It was found that the extent of the transition ranges for the bulk and shear response were comparable. Comparison of the shift factors for bulk and shear responses supports the idea that different molecular mechanisms contribute to shear and bulk deformations. The second chapter delineates molecular dynamics computations for the bulk response for a range of pressures and temperatures. The model(s) consisted of 2256 atoms formed into three polymer chains with fifty monomer units per chain per unit cell. The time scales accessed were limited to tens of pico seconds. It was found that, in addition to the typical energy minimization and temperature annealing cycles for establishing equilibrium models, it is advantageous to subject the model samples to a cycle of relatively large pressures (GPa-range) for improving the equilibrium state. On comparing the computations with the experimentally determined "glassy" behavior, one finds that, although the computations were limited to small samples in a physical sense, the primary limitation rests in the very short times (pico seconds). The molecular dynamics computations do not model the physically observed temperature sensitivity of PMMA, even if one employs a hypothetical time-temperature shift to account for the large difference in time scales between experiment and computation. The values computed by the molecular dynamics method do agree with the values measured at the coldest temperature and at the highest frequency of one kiloHertz. The third chapter draws on measurements of uniaxial, shear and Poisson response conducted previously in our laboratory. With the availability of four time or frequency-dependent material functions for the same material, the process of interconversion between different material functions was investigated. Computed material functions were evaluated against the direct experimental measurements and the limitations imposed on successful interconversion due to the experimental errors in the underlying physical data were explored. Differences were observed that are larger than the experimental errors would suggest.

  5. Association between CFH, CFB, ARMS2, SERPINF1, VEGFR1 and VEGF polymorphisms and anatomical and functional response to ranibizumab treatment in neovascular age-related macular degeneration.

    PubMed

    Cobos, Estefania; Recalde, Sergio; Anter, Jaouad; Hernandez-Sanchez, Maria; Barreales, Carla; Olavarrieta, Leticia; Valverde, Alicia; Suarez-Figueroa, Marta; Cruz, Fernando; Abraldes, Maximino; Pérez-Pérez, Julian; Fernández-Robredo, Patricia; Arias, Luis; García-Layana, Alfredo

    2018-03-01

    We sought to determine if specific genetic single nucleotide polymorphisms (SNPs) influence vascular endothelial growth factor inhibition response to ranibizumab in neovascular age-related macular degeneration (AMD). A total of 403 Caucasian patients diagnosed with exudative AMD were included. After a three-injection loading phase, a pro re nata regimen was followed. Nine SNPs from six different genes (CFH, CFB, ARMS2, SERPINF1, VEGFR1, VEGF) were genotyped. Non-genetic risk factors (gender, smoking habit and hypertension) were also assessed. Patients were classified as good or poor responders (GR or PR) according to functional (visual acuity), anatomical (foveal thickness measured by OCT) and fluid criteria (fluid/no fluid measured by OCT). Hypertension was the environmental factor with the strongest poor response association with ranibizumab in the anatomical measure after the loading phase (p = 0.0004; OR 3.7; 95% CI, 2.4-5.8) and after 12 months of treatment (p = 10 -5 ; OR 2.3; 95% CI, 1.5-3.4). The genetic variants rs12614 (CFB), rs699947 (VEGFA) and rs7993418 (VEGFR1) predisposed patients to a good response, while rs12603486 and rs1136287 (SERPINF1) were associated with a poor response. The protective genotype of rs800292 variant (CFH) was also associated with a poor anatomical response (p 0.0048). All these data suggest that genetics play an important role in treatment response in AMD patients. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  6. Influence of dexmedetomidine on cognitive function in volunteers.

    PubMed

    Yatabe, Tomoaki; Tamura, Takahiko; Yamashita, Koichi; Yokoyama, Masataka

    2016-09-01

    Some outpatient procedures are performed under sedation with dexmedetomidine, although the effect of dexmedetomidine on cognitive function remains unclear. This study investigated the effect of dexmedetomidine on cognitive function in healthy volunteers. Observation study in volunteers. University-affiliated teaching hospital. Six healthy volunteers. After infusion of a 6-μg/kg per hour loading dose of dexmedetomidine for 10 minutes, a maintenance infusion of 0.4 μg/kg per hour was administered for 4 hours. Cognitive function was evaluated before infusion (baseline) and at 2, 4, 6, and 8 hours after infusion. Cognitive function, response speed, accuracy, and consistency were measured by CogHealth. Depth of sedation was evaluated at 1-hour intervals by evaluating the Bispectral Index. Data are presented as the change from baseline. The Bispectral Index value was significantly lower from 10 minutes to 6 hours after infusion versus the pre-infusion value. Response speed was also significantly lower at 2 hours and 4 hours after infusion (92 ± 8%, P< .0001; 93 ± 6%, P< .0001), as was consistency (96 ± 7%, P= .0009; 96 ± 5%, P= .0003). Response accuracy was unaltered by the infusion. Dexmedetomidine slightly reduced response speed and consistency, but did not affect response accuracy. Cognitive function was restored to pre-administration values 2 hours after the infusion of dexmedetomidine was discontinued. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Does Your Optical Particle Counter Measure What You Think it Does? Calibration and Refractive Index Correction Methods.

    NASA Astrophysics Data System (ADS)

    Rosenberg, Phil; Dean, Angela; Williams, Paul; Dorsey, James; Minikin, Andreas; Pickering, Martyn; Petzold, Andreas

    2013-04-01

    Optical Particle Counters (OPCs) are the de-facto standard for in-situ measurements of airborne aerosol size distributions and small cloud particles over a wide size range. This is particularly the case on airborne platforms where fast response is important. OPCs measure scattered light from individual particles and generally bin particles according to the measured peak amount of light scattered (the OPC's response). Most manufacturers provide a table along with their instrument which indicates the particle diameters which represent the edges of each bin. It is important to correct the particle size reported by OPCs for the refractive index of the particles being measured, which is often not the same as for those used during calibration. However, the OPC's response is not a monotonic function of particle diameter and obvious problems occur when refractive index corrections are attempted, but multiple diameters correspond to the same OPC response. Here we recommend that OPCs are calibrated in terms of particle scattering cross section as this is a monotonic (usually linear) function of an OPC's response. We present a method for converting a bin's boundaries in terms of scattering cross section into a bin centre and bin width in terms of diameter for any aerosol species for which the scattering properties are known. The relationship between diameter and scattering cross section can be arbitrarily complex and does not need to be monotonic; it can be based on Mie-Lorenz theory or any other scattering theory. Software has been provided on the Sourceforge open source repository for scientific users to implement such methods in their own measurement and calibration routines. As a case study data is presented showing data from Passive Cavity Aerosol Spectrometer Probe (PCASP) and a Cloud Droplet Probe (CDP) calibrated using polystyrene latex spheres and glass beads before being deployed as part of the Fennec project to measure airborne dust in the inaccessible regions of the Sahara.

  8. Measuring executive function in Indian mothers and their 4-year-old daughters.

    PubMed

    von Suchodoletz, Antje; Slot, Pauline L; Shroff, Delshad M

    2017-03-01

    Executive function (EF), including cognitive flexibility, attention shifting, and inhibitory control, has been linked to a range of outcomes across the lifespan, such as school readiness and academic functioning, job performance, health, and social-emotional well-being. Yet, research investigating links between parent EF and child EF is still limited. This is partly due to challenges in measuring the same EF abilities in parents and their children. The current study investigated the applicability of a computer-based battery of various EF tasks for use with both mothers and children. The battery included the following EF tasks: Dimensional Change Card Sort, Hearts and Flowers, and Fish Flanker. Participants were 80 Indian mothers and their 4-year-old daughters. EF was measured with regard to accuracy scores, response time, and inverse efficiency (IE) scores of the most complex blocks of each task. Scoring patterns indicated that children's task performance appeared to be determined by their ability to recognize the cue indicating which task to perform at any given trial and to inhibit an incorrect response. In contrast, mothers' performance appeared to be determined by response time, that is, their ability to be quick in giving the correct response. However, for both children and mothers, IE scores best captured individual differences in EF performance between participants. Furthermore, confirmatory factor analyses found that, for both children and mothers, all EF measures loaded on a latent factor, suggesting that the measures shared common variance in EF. There appeared to be no significant association between mothers' and children's EF scores, controlling for several background variables. Directions for further research include examining the applicability of the EF task battery to reliably describe developmental trajectories of EF abilities over time, and further examining variability in the parent-child EF association across the lifespan. © 2017 The Institute of Psychology, Chinese Academy of Sciences and John Wiley & Sons Australia, Ltd.

  9. Test systems for measuring ocular parameters and visual function in mice.

    PubMed

    Schaeffel, Frank

    2008-05-01

    New techniques are described to measure refractive state, pupil responses, corneal curvature, ocular dimensions and spatial vision in mice. These variables are important for studies on myopia development in mice, but they are also valuable for phenotyping mouse mutants and for pharmacological studies.

  10. Temporal Preparation and Inhibitory Deficit in Fibromyalgia Syndrome

    ERIC Educational Resources Information Center

    Correa, Angel; Miro, Elena; Martinez, M. Pilar; Sanchez, Ana I.; Lupianez, Juan

    2011-01-01

    Cognitive deficits in fibromyalgia may be specifically related to controlled processes, such as those measured by working memory or executive function tasks. This hypothesis was tested here by measuring controlled temporal preparation (temporal orienting) during a response inhibition (go no-go) task. Temporal orienting effects (faster reaction…

  11. Measurement of Device Parameters Using Image Recovery Techniques in Large-Scale IC Devices

    NASA Technical Reports Server (NTRS)

    Scheick, Leif; Edmonds, Larry

    2004-01-01

    Devices that respond to radiation on a cell level will produce histograms showing the relative frequency of cell damage as a function of damage. The measured distribution is the convolution of distributions from radiation responses, measurement noise, and manufacturing parameters. A method of extracting device characteristics and parameters from measured distributions via mathematical and image subtraction techniques is described.

  12. Effects of rearing temperature on immune functions in sockeye salmon (Oncorhynchus nerka)

    USGS Publications Warehouse

    Alcorn, S.W.; Murray, A.L.; Pascho, R.J.

    2002-01-01

    To determine if the defences of sockeye salmon (Oncorhynchus nerka) raised in captivity are affected by the rearing temperature or their life-cycle stage, various indices of the humoral and cellular immune functions were measured in fish reared at either 8 or 12??C for their entire life-cycle. Measures of humoral immunity included the commonly used haematological parameters, as well as measurements of complement, and lysozyme activity. Cellular assays quantified the ability of macrophages from the anterior kidney to phagocytise Staphylococcus aureus cells, or the activities of certain bactericidal systems of those cells. The T-dependent antibody response to a recombinant 57 kDa protein of Renibacterium salmoninarum was used to quantify the specific immune response. Fish were sampled during the spring and fall of their second, third and fourth years, corresponding to a period that began just before smolting and ended at sexual maturation. Fish reared at 8??C tended to have a greater percentage of phagocytic kidney macrophages during the first 2 years of sampling than the fish reared at 12??C. During the last half of the study the complement activity of the fish reared at 8??C was greater than that of the 12??C fish. Conversely, a greater proportion of the blood leucocytes were lymphocytes in fish reared at 12??C compared to the fish reared at 8??C. Fish reared at 12??C also produced a greater antibody response than those reared at 8??C. Results suggested that the immune apparatus of sockeye salmon reared at 8??C relied more heavily on the non-specific immune response, while the specific immune response was used to a greater extent when the fish were reared at 12??C. Although a seasonal effect was not detected in any of the indices measured, varying effects were observed in some measurements during sexual maturation of fish in both temperature groups. At that time there were dramatic decreases in complement activity and lymphocyte numbers. This study was unique in its scope because it was the first quantitative assessment of salmon immune functions for an entire life-cycle. ?? 2002 Elsevier Science Ltd.

  13. Obesity, change of body mass index and subsequent physical and mental health functioning: a 12-year follow-up study among ageing employees.

    PubMed

    Svärd, Anna; Lahti, Jouni; Roos, Eira; Rahkonen, Ossi; Lahelma, Eero; Lallukka, Tea; Mänty, Minna

    2017-09-26

    Studies suggest an association between weight change and subsequent poor physical health functioning, whereas the association with mental health functioning is inconsistent. We aimed to examine whether obesity and change of body mass index among normal weight, overweight and obese women and men associate with changes in physical and mental health functioning. The Helsinki Health Study cohort includes Finnish municipal employees aged 40 to 60 in 2000-02 (phase 1, response rate 67%). Phase 2 mail survey (response rate 82%) took place in 2007 and phase 3 in 2012 (response rate 76%). This study included 5668 participants (82% women). Seven weight change categories were formed based on body mass index (BMI) (phase 1) and weight change (BMI change ≥5%) (phase 1-2). The Short Form 36 Health Survey (SF-36) measured physical and mental health functioning. The change in health functioning (phase 1-3) score was examined with repeated measures analyses. Covariates were age, sociodemographic factors, health behaviours, and somatic ill-health. Weight gain was common among women (34%) and men (25%). Weight-gaining normal weight (-1.3 points), overweight (-1.3 points) and obese (-3.6 points) women showed a greater decline in physical component summary scores than weight-maintaining normal weight women. Among weight-maintainers, only obese (-1.8 points) women showed a greater decline than weight-maintaining normal weight women. The associations were similar, but statistically non-significant for obese men. No statistically significant differences in the change in mental health functioning occurred. Preventing weight gain likely helps maintaining good physical health functioning and work ability.

  14. Effects of Detrital Subsidies on Soft-Sediment Ecosystem Function Are Transient and Source-Dependent.

    PubMed

    Gladstone-Gallagher, Rebecca V; Lohrer, Andrew M; Lundquist, Carolyn J; Pilditch, Conrad A

    2016-01-01

    Detrital subsidies from marine macrophytes are prevalent in temperate estuaries, and their role in structuring benthic macrofaunal communities is well documented, but the resulting impact on ecosystem function is not understood. We conducted a field experiment to test the effects of detrital decay on soft-sediment primary production, community metabolism and nutrient regeneration (measures of ecosystem function). Twenty four (2 m2) plots were established on an intertidal sandflat, to which we added 0 or 220 g DW m-2 of detritus from either mangroves (Avicennia marina), seagrass (Zostera muelleri), or kelp (Ecklonia radiata) (n = 6 plots per treatment). Then, after 4, 17 and 46 d we measured ecosystem function, macrofaunal community structure and sediment properties. We hypothesized that (1) detrital decay would stimulate benthic primary production either by supplying nutrients to the benthic macrophytes, or by altering the macrofaunal community; and (2) ecosystem responses would depend on the stage and rate of macrophyte decay (a function of source). Avicennia detritus decayed the slowest with a half-life (t50) of 46 d, while Zostera and Ecklonia had t50 values of 28 and 2.6 d, respectively. However, ecosystem responses were not related to these differences. Instead, we found transient effects (up to 17 d) of Avicennia and Ecklonia detritus on benthic primary production, where initially (4 d) these detrital sources suppressed primary production, but after 17 d, primary production was stimulated in Avicennia plots relative to controls. Other ecosystem function response variables and the macrofaunal community composition were not altered by the addition of detritus, but did vary with time. By sampling ecosystem function temporally, we were able to capture the in situ transient effects of detrital subsidies on important benthic ecosystem functions.

  15. Antibody Functional Assays as Measures of Fc Receptor-Mediated Immunity to HIV - New Technologies and their Impact on the HIV Vaccine Field.

    PubMed

    Wines, Bruce D; Billings, Hugh; Mclean, Milla R; Kent, Stephen J; Hogarth, P Mark

    2017-01-01

    There is now intense interest in the role of HIV-specific antibodies and the engagement of FcγR functions in the control and prevention of HIV infection. The analyses of the RV144 vaccine trial, natural progression cohorts, and macaque models all point to a role for Fc-dependent effector functions, such as cytotoxicity (ADCC) or phagocytosis (ADCP), in the control of HIV. However, reliable assays that can be reproducibly used across different laboratories to measure Fcdependent functions, such as antibody dependent cellular cytotoxicity (ADCC) are limited. This brief review highlights the importance of Fc properties for immunity to HIV, particularly via FcγR diversity and function. We discuss assays used to study FcR mediated functions of HIV-specific Ab, including our recently developed novel cell-free ELISA using homo-dimeric FcγR ectodomains to detect functionally relevant viral antigen-specific antibodies. The binding of these dimeric FcγR ectodomains, to closely spaced pairs of IgG Fc, mimics the engagement and cross-linking of Fc receptors by IgG opsonized virions or infected cells as the essential prerequisite to the induction of Ab-dependent effector functions. The dimeric FcγR ELISA reliably correlates with ADCC in patient responses to influenza. The assay is amenable to high throughput and could be standardized across laboratories. We propose the assay has broader implications for the evaluation of the quality of antibody responses in viral infections and for the rapid evaluation of responses in vaccine development campaigns for HIV and other viral infections. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  16. Antibody Functional Assays as Measures of Fc Receptor-Mediated Immunity to HIV - New Technologies and their Impact on the HIV Vaccine Field

    PubMed Central

    Wines, Bruce D.; Billings, Hugh; Mclean, Milla R.; Kent, Stephen J.; Hogarth, P. Mark

    2017-01-01

    Background: There is now intense interest in the role of HIV-specific antibodies and the engagement of FcγR functions in the control and prevention of HIV infection. The analyses of the RV144 vaccine trial, natural progression cohorts, and macaque models all point to a role for Fc-dependent effector functions, such as cytotoxicity (ADCC) or phagocytosis (ADCP), in the control of HIV. However, reliable assays that can be reproducibly used across different laboratories to measure Fc-dependent functions, such as antibody dependent cellular cytotoxicity (ADCC) are limited. Method: This brief review highlights the importance of Fc properties for immunity to HIV, particular-ly via FcγR diversity and function. We discuss assays used to study FcR mediated functions of HIV-specific Ab, including our recently developed novel cell-free ELISA using homo-dimeric FcγR ecto-domains to detect functionally relevant viral antigen-specific antibodies. Results: The binding of these dimeric FcγR ectodomains, to closely spaced pairs of IgG Fc, mimics the engagement and cross-linking of Fc receptors by IgG opsonized virions or infected cells as the es-sential prerequisite to the induction of Ab-dependent effector functions. The dimeric FcγR ELISA reli-ably correlates with ADCC in patient responses to influenza. The assay is amenable to high throughput and could be standardized across laboratories. Conclusion: We propose the assay has broader implications for the evaluation of the quality of anti-body responses in viral infections and for the rapid evaluation of responses in vaccine development campaigns for HIV and other viral infections. PMID:28322167

  17. Vision-based flight control in the hawkmoth Hyles lineata

    PubMed Central

    Windsor, Shane P.; Bomphrey, Richard J.; Taylor, Graham K.

    2014-01-01

    Vision is a key sensory modality for flying insects, playing an important role in guidance, navigation and control. Here, we use a virtual-reality flight simulator to measure the optomotor responses of the hawkmoth Hyles lineata, and use a published linear-time invariant model of the flight dynamics to interpret the function of the measured responses in flight stabilization and control. We recorded the forces and moments produced during oscillation of the visual field in roll, pitch and yaw, varying the temporal frequency, amplitude or spatial frequency of the stimulus. The moths’ responses were strongly dependent upon contrast frequency, as expected if the optomotor system uses correlation-type motion detectors to sense self-motion. The flight dynamics model predicts that roll angle feedback is needed to stabilize the lateral dynamics, and that a combination of pitch angle and pitch rate feedback is most effective in stabilizing the longitudinal dynamics. The moths’ responses to roll and pitch stimuli coincided qualitatively with these functional predictions. The moths produced coupled roll and yaw moments in response to yaw stimuli, which could help to reduce the energetic cost of correcting heading. Our results emphasize the close relationship between physics and physiology in the stabilization of insect flight. PMID:24335557

  18. Vision-based flight control in the hawkmoth Hyles lineata.

    PubMed

    Windsor, Shane P; Bomphrey, Richard J; Taylor, Graham K

    2014-02-06

    Vision is a key sensory modality for flying insects, playing an important role in guidance, navigation and control. Here, we use a virtual-reality flight simulator to measure the optomotor responses of the hawkmoth Hyles lineata, and use a published linear-time invariant model of the flight dynamics to interpret the function of the measured responses in flight stabilization and control. We recorded the forces and moments produced during oscillation of the visual field in roll, pitch and yaw, varying the temporal frequency, amplitude or spatial frequency of the stimulus. The moths' responses were strongly dependent upon contrast frequency, as expected if the optomotor system uses correlation-type motion detectors to sense self-motion. The flight dynamics model predicts that roll angle feedback is needed to stabilize the lateral dynamics, and that a combination of pitch angle and pitch rate feedback is most effective in stabilizing the longitudinal dynamics. The moths' responses to roll and pitch stimuli coincided qualitatively with these functional predictions. The moths produced coupled roll and yaw moments in response to yaw stimuli, which could help to reduce the energetic cost of correcting heading. Our results emphasize the close relationship between physics and physiology in the stabilization of insect flight.

  19. Antigen-specific T cell responses to BK polyomavirus antigens identify functional anti-viral immunity and may help to guide immunosuppression following renal transplantation

    PubMed Central

    Chakera, A; Bennett, S; Lawrence, S; Morteau, O; Mason, P D; O'Callaghan, C A; Cornall, R J

    2011-01-01

    Infection with the polyoma virus BK (BKV) is a major cause of morbidity following renal transplantation. Limited understanding of the anti-viral immune response has prevented the design of a strategy that balances treatment with the preservation of graft function. The proven utility of interferon-gamma enzyme-linked immunospot (ELISPOT) assays to measure T cell responses in immunocompetent hosts was the basis for trying to develop a rational approach to the management of BKV following renal transplantation. In a sample of transplant recipients and healthy controls, comparisons were made between T cell responses to the complete panel of BKV antigens, the Epstein–Barr virus (EBV) antigens, BZLF1 and EBNA1, and the mitogen phytohaemagglutinin (PHA). Correlations between responses to individual antigens and immunosuppressive regimens were also analysed. Antigen-specific T cell responses were a specific indicator of recent or ongoing recovery from BKV infection (P < 0·05), with responses to different BKV antigens being highly heterogeneous. Significant BKV immunity was undetectable in transplant patients with persistent viral replication or no history of BKV reactivation. Responses to EBV antigens and mitogen were reduced in patients with BKV reactivation, but these differences were not statistically significant. The T cell response to BKV antigens is a useful and specific guide to recovery from BKV reactivation in renal transplant recipients, provided that the full range of antigenic responses is measured. PMID:21671906

  20. Differences in performance and learning proficiency on the Wisconsin Card Sorting Test in schizophrenia: do they reflect distinct neurocognitive subtypes with distinct functional profiles?

    PubMed

    Kurtz, Matthew M; Wexler, Bruce E

    2006-01-31

    The aim of this study was two-fold: 1) to determine whether a priori subtyping of patients with schizophrenia based on both overall performance on a measure of executive-function, the Wisconsin Card Sorting Test (WCST), and ability to learn the task with expanded instruction, could be confirmed with other, independent measures of executive-function and learning, and, if so, 2) to determine whether these groups have different neurocognitive profiles and show differences in functional capacity. Fifty-four outpatients with schizophrenia were divided by WCST performance into three groups: intact executive-function (n=28), "good learner" (n=13), and "poor learner" (n=13) groups. These groups were then assessed with a comprehensive neurocognitive test battery and a performance-based measure of functional status, the UCSD Performance-based Skills Assessment (UPSA). The WCST-intact subgroup performed significantly better than other groups on a second measure of executive-function and in working memory, and speeded motor sequencing. Impaired WCST patients who benefited from expanded WCST instruction ("good learners") also showed better performance than patients who did not benefit from instruction ("poor-learners") on a second measure of learning, as well as on a measure of auditory divided attention. The intact WCST subgroup had greater functional capacity than either "strong" or "poor" learners. These subtypes may have implications for response to behavioral treatment interventions.

  1. Estimation of the Nonlinear Random Coefficient Model when Some Random Effects Are Separable

    ERIC Educational Resources Information Center

    du Toit, Stephen H. C.; Cudeck, Robert

    2009-01-01

    A method is presented for marginal maximum likelihood estimation of the nonlinear random coefficient model when the response function has some linear parameters. This is done by writing the marginal distribution of the repeated measures as a conditional distribution of the response given the nonlinear random effects. The resulting distribution…

  2. Testing Manifest Monotonicity Using Order-Constrained Statistical Inference

    ERIC Educational Resources Information Center

    Tijmstra, Jesper; Hessen, David J.; van der Heijden, Peter G. M.; Sijtsma, Klaas

    2013-01-01

    Most dichotomous item response models share the assumption of latent monotonicity, which states that the probability of a positive response to an item is a nondecreasing function of a latent variable intended to be measured. Latent monotonicity cannot be evaluated directly, but it implies manifest monotonicity across a variety of observed scores,…

  3. A Functional Measurement Study on Averaging Numerosity

    ERIC Educational Resources Information Center

    Tira, Michael D.; Tagliabue, Mariaelena; Vidotto, Giulio

    2014-01-01

    In two experiments, participants judged the average numerosity between two sequentially presented dot patterns to perform an approximate arithmetic task. In Experiment 1, the response was given on a 0-20 numerical scale (categorical scaling), and in Experiment 2, the response was given by the production of a dot pattern of the desired numerosity…

  4. Influence of Image Interactivity on Approach Responses towards an Online Retailer.

    ERIC Educational Resources Information Center

    Fiore, Ann Marie; Jin, Hyun-Jeong

    2003-01-01

    Measured the effect of exposure to an image interactivity function from an apparel retailer's Web site on approach responses towards the retailer. Dependent variables included attitude towards the online store, willingness to purchase, probability of spending more time than planned shopping, and likelihood of patronizing the online retailer's…

  5. FLUKA simulation of TEPC response to cosmic radiation.

    PubMed

    Beck, P; Ferrari, A; Pelliccioni, M; Rollet, S; Villari, R

    2005-01-01

    The aircrew exposure to cosmic radiation can be assessed by calculation with codes validated by measurements. However, the relationship between doses in the free atmosphere, as calculated by the codes and from results of measurements performed within the aircraft, is still unclear. The response of a tissue-equivalent proportional counter (TEPC) has already been simulated successfully by the Monte Carlo transport code FLUKA. Absorbed dose rate and ambient dose equivalent rate distributions as functions of lineal energy have been simulated for several reference sources and mixed radiation fields. The agreement between simulation and measurements has been well demonstrated. In order to evaluate the influence of aircraft structures on aircrew exposure assessment, the response of TEPC in the free atmosphere and on-board is now simulated. The calculated results are discussed and compared with other calculations and measurements.

  6. Spectral characterization of plastic scintillation detector response as a function of magnetic field strength

    NASA Astrophysics Data System (ADS)

    Simiele, E.; Kapsch, R.-P.; Ankerhold, U.; Culberson, W.; DeWerd, L.

    2018-04-01

    The purpose of this work was to characterize intensity and spectral response changes in a plastic scintillation detector (PSD) as a function of magnetic field strength. Spectra measurements as a function of magnetic field strength were performed using an optical spectrometer. The response of both a PSD and PMMA fiber were investigated to isolate the changes in response from the scintillator and the noise signal as a function of magnetic field strength. All irradiations were performed in water at a photon beam energy of 6 MV. Magnetic field strengths of (0, ±0.35, ±0.70, ±1.05, and  ±1.40) T were investigated. Four noise subtraction techniques were investigated to evaluate the impact on the resulting noise-subtracted scintillator response with magnetic field strength. The noise subtraction methods included direct spectral subtraction, the spectral method, and variants thereof. The PMMA fiber exhibited changes in response of up to 50% with magnetic field strength due to the directional light emission from \\breve{C} erenkov radiation. The PSD showed increases in response of up to 10% when not corrected for the noise signal, which agrees with previous investigations of scintillator response in magnetic fields. Decreases in the \\breve{C} erenkov light ratio with negative field strength were observed with a maximum change at  ‑1.40 T of 3.2% compared to 0 T. The change in the noise-subtracted PSD response as a function of magnetic field strength varied with the noise subtraction technique used. Even after noise subtraction, the PSD exhibited changes in response of up to 5.5% over the four noise subtraction methods investigated.

  7. Ride quality criteria. [transportation system interior and passenger response to environment

    NASA Technical Reports Server (NTRS)

    Stephens, D. G.

    1977-01-01

    Ride quality refers to the interior or passenger environment of a transportation system as well as the passenger response to the environment. Ride quality factors are illustrated with the aid of a diagram presenting inputs to vehicle, the vehicle transfer function, the ride environment, the passenger response function, and the passenger ride response. The reported investigation considers the ride environment as measured on a variety of air and surface vehicles, the passenger response to the environment as determined from laboratory and field surveys, and criteria/standards for vibration, noise, and combined stimuli. Attention is given to the vertical vibration characteristics in cruise for aircraft and automobile, the aircraft vibration levels for various operating regimes, comparative noise levels during cruise, the discomfort level for a 9 Hz sinusoidal vibration, equal discomfort contours for vertical vibration, subjective response to noise in a speech situation, and noise and vibration levels for constant discomfort contours.

  8. Measurement and Reliability of Response Inhibition

    PubMed Central

    Congdon, Eliza; Mumford, Jeanette A.; Cohen, Jessica R.; Galvan, Adriana; Canli, Turhan; Poldrack, Russell A.

    2012-01-01

    Response inhibition plays a critical role in adaptive functioning and can be assessed with the Stop-signal task, which requires participants to suppress prepotent motor responses. Evidence suggests that this ability to inhibit a prepotent motor response (reflected as Stop-signal reaction time (SSRT)) is a quantitative and heritable measure of interindividual variation in brain function. Although attention has been given to the optimal method of SSRT estimation, and initial evidence exists in support of its reliability, there is still variability in how Stop-signal task data are treated across samples. In order to examine this issue, we pooled data across three separate studies and examined the influence of multiple SSRT calculation methods and outlier calling on reliability (using Intra-class correlation). Our results suggest that an approach which uses the average of all available sessions, all trials of each session, and excludes outliers based on predetermined lenient criteria yields reliable SSRT estimates, while not excluding too many participants. Our findings further support the reliability of SSRT, which is commonly used as an index of inhibitory control, and provide support for its continued use as a neurocognitive phenotype. PMID:22363308

  9. A revision of existing Karolinska Sleepiness Scale responses to light: A melanopic perspective.

    PubMed

    Hommes, Vanja; Giménez, Marina C

    2015-01-01

    A new photometric measure of light intensity that takes into account the relatively large contribution of the ipRGCs to the non-image forming (NIF) system was recently proposed. We set out to revise publications reporting on alertness scores as measured by the Karolinska Sleepiness Scale (KSS) under different light conditions in order to assess the extendibility of the equivalent-melanopic function to NIF responses in humans. The KSS response (-Δ KSS) to the different light conditions used on previous studies, preferably including a comparison to a dim light condition, was assessed. Based on the light descriptions of the different studies, the equivalent melanopic lux (m-illuminance) was calculated. The -Δ KSS was plotted against photopic-illuminance and m-illuminance, and fitted to a sigmoidal function already shown to described KSS responses to different light intensities. The root mean-squared error and r(2) were used as criteria to explain the best-describing light unit measurement. Studies that compared only the influence of light under otherwise same conditions and in which participants were not totally sleep deprived were included. Our results show that the effects of light on KSS are better explained by a melanopic unit measurement than by photopic lux. The present analysis allowed for the construction of a melanopic alertness response curve. This curve needs to be validated with appropriate designs. Nonetheless, it may serve as starting point for the development of hypothesis of predictions on the relative changes in KSS under a given condition due to changes in light properties.

  10. An investigation of soil-structure interaction effects observed at the MIT Green Building

    USGS Publications Warehouse

    Taciroglu, Ertugrul; Çelebi, Mehmet; Ghahari, S. Farid; Abazarsa, Fariba

    2016-01-01

    The soil-foundation impedance function of the MIT Green Building is identified from its response signals recorded during an earthquake. Estimation of foundation impedance functions from seismic response signals is a challenging task, because: (1) the foundation input motions (FIMs) are not directly measurable, (2) the as-built properties of the super-structure are only approximately known, and (3) the soil-foundation impedance functions are inherently frequency-dependent. In the present study, aforementioned difficulties are circumvented by using, in succession, a blind modal identification (BMID) method, a simplified Timoshenko beam model (TBM), and a parametric updating of transfer functions (TFs). First, the flexible-base modal properties of the building are identified from response signals using the BMID method. Then, a flexible-base TBM is updated using the identified modal data. Finally, the frequency-dependent soil-foundation impedance function is estimated by minimizing the discrepancy between TFs (of pairs instrumented floors) that are (1) obtained experimentally from earthquake data and (2) analytically from the updated TBM. Using the fully identified flexible-base TBM, the FIMs as well as building responses at locations without instruments can be predicted, as demonstrated in the present study.

  11. Functional imaging of hemodynamic stimulus response in the rat retina with ultrahigh-speed spectral / Fourier domain OCT

    NASA Astrophysics Data System (ADS)

    Choi, WooJhon; Baumann, Bernhard; Clermont, Allen C.; Feener, Edward P.; Boas, David A.; Fujimoto, James G.

    2013-03-01

    Measuring retinal hemodynamics in response to flicker stimulus is important for investigating pathophysiology in small animal models of diabetic retinopathy, because a reduction in the hyperemic response is thought to be one of the earliest changes in diabetic retinopathy. In this study, we investigated functional imaging of retinal hemodynamics in response to flicker stimulus in the rat retina using an ultrahigh speed spectral / Fourier domain OCT system at 840nm with an axial scan rate of 244kHz. At 244kHz the nominal axial velocity range that could be measured without phase wrapping was +/-37.7mm/s. Pulsatile total retinal arterial blood flow as a function of time was measured using an en face Doppler approach where a 200μm × 200μm area centered at the central retinal artery was repeatedly raster scanned at a volume acquisition rate of 55Hz. Three-dimensional capillary imaging was performed using speckle decorrelation which has minimal angle dependency compared to other angiography techniques based on OCT phase information. During OCT imaging, a flicker stimulus could be applied to the retina synchronously by inserting a dichroic mirror in the imaging interface. An acute transient increase in total retinal blood flow could be detected. At the capillary level, an increase in the degree of speckle decorrelation in capillary OCT angiography images could also be observed, which indicates an increase in the velocity of blood at the capillary level. This method promises to be useful for the investigation of small animal models of ocular diseases.

  12. Functional MR imaging of the cervical spinal cord by use of electrical stimulation at LI4 (Hegu).

    PubMed

    Wang, W D; Kong, K M; Xiao, Y Y; Wang, X J; Liang, B; Qi, W L; Wu, R H

    2006-01-01

    The purpose is to investigate the cervical spinal cord mapping on electrical stimulation at LI4 (Hegu) by using 'signal enhancement by extravascular water protons' (SEEP)-fMRI, and to establish the response of acupoint-stimulation in spinal cord. Three healthy volunteers were underwent low-frequency electrical stimulation at LI4. Meanwhile, a single-shot fast spin-echo (SSFSE) sequence was used to perform functional MR imaging on a 1.5 T GE Signa MR system. Cord activation was measured both in the sagittal and transverse imaging planes and then analyzed by AFNI (analysis of functional neuroimages) system. In the sagittal view, two subjects had an fMRI response in the cervical spinal cord upon electrical stimulation at LI4. The localizations of the segmental fMRI activation are both at C6 through T1 and C2/3 cervical spinal cord level. In the transverse imaging plane, significant fMRI responses could be measured in the last subjects locating at C6/7 segment, the cross-sectional localization of the activity measured in the spinal cord was most in terms of the ipsilateral posterior direction. It is concluded that the fMRI technique can be used for detecting with activity in the human cervical spinal cord by a single-shot fast spin-echo sequence on a 1.5 T GE clinical system. Investigating the acupoint-stimulation response in the spinal cord using the spinal fMRI will be helpful for the further discussion on the mechanisms of acupuncture to spinal cord diseases.

  13. Lung function and exhaled nitric oxide in healthy unsedated African infants

    PubMed Central

    Gray, Diane; Willemse, Lauren; Visagie, Ane; Smith, Emilee; Czövek, Dorottya; Sly, Peter D; Hantos, Zoltán; Hall, Graham L; Zar, Heather J

    2015-01-01

    Background and objective Population-appropriate lung function reference data are essential to accurately identify respiratory disease and measure response to interventions. There are currently no reference data in African infants. The aim was to describe normal lung function in healthy African infants. Methods Lung function was performed on healthy South African infants enrolled in a birth cohort study, the Drakenstein child health study. Infants were excluded if they were born preterm or had a history of neonatal respiratory distress or prior respiratory tract infection. Measurements, made during natural sleep, included the forced oscillation technique, tidal breathing, exhaled nitric oxide and multiple breath washout measures. Results Three hundred sixty-three infants were tested. Acceptable and repeatable measurements were obtained in 356 (98%) and 352 (97%) infants for tidal breathing analysis and exhaled nitric oxide outcomes, 345 (95%) infants for multiple breath washout and 293 of the 333 (88%) infants for the forced oscillation technique. Age, sex and weight-for-age z score were significantly associated with lung function measures. Conclusions This study provides reference data for unsedated infant lung function in African infants and highlights the importance of using population-specific data. PMID:26134556

  14. Peripheral functional organisation of vagally evoked gastric motor responses in the ferret.

    PubMed Central

    Andrews, P L; Lawes, I N; Bower, A J

    1980-01-01

    The aims of the present study were to determine the relative amplitudes of intragastric motor responses evoked by different vagal branches and to establish whether the effects of acute or chronic vagotomy could be predicted from these data. Intragastric pressure responses to electrical stimulation of the vagus were measured in urethane-anaesthetised ferrets and acute or chronic vagotomies were performed. The results show that the left and right cervical vagi were equipotential and fully overlaped each other. Their contributions to the dorsal trunk were equipotential and fully overlapping and so were their contributions to the ventral trunk. The dorsal trunk was more effective than the ventral trunk and there was total functional overlap between these two trunks. Vagal evoked gastric motor responses of the ferret are apparently organised in a different way from vagally induced acid secretion or hormone release in the cat. Acute removal of a trunk led to a reduction in evoked responses that was not linear function of the effect of stimulation of that trunk. In contrast, chronic removal caused a relative increase in evoked responses that ws inversely related to the decrease caused by acute removal. The implications of total functional overlap and neuromuscular reorganisation after chronic vagotomy are discussed. PMID:7439800

  15. Depersonalization experiences in undergraduates are related to heightened stress cortisol responses.

    PubMed

    Giesbrecht, Timo; Smeets, Tom; Merckelbach, Harald; Jelicic, Marko

    2007-04-01

    The relationship between dissociative tendencies, as measured with the Dissociative Experiences Scale and its amnesia, absorption/imaginative involvement, and depersonalization/derealization subscales, and HPA axis functioning was studied in 2 samples of undergraduate students (N = 58 and 67). Acute stress was induced by means of the Trier Social Stress Test. Subjective and physiological stress (i.e., cortisol) responses were measured. Individuals high on the depersonalization/derealization subscale of the Dissociative Experiences Scale exhibited more pronounced cortisol responses, while individuals high on the absorption subscale showed attenuated responses. Interestingly, subjective stress experiences, as indicated by the Tension-Anxiety subscale of the Profile of Mood States, were positively related to trait dissociation. The present findings illustrate how various types of dissociation (i.e., depersonalization/derealization, absorption) are differentially related to cortisol stress responses.

  16. Standardization of UV LED measurements

    NASA Astrophysics Data System (ADS)

    Eppeldauer, G. P.; Larason, T. C.; Yoon, H. W.

    2015-09-01

    Traditionally used source spectral-distribution or detector spectral-response based standards cannot be applied for accurate UV LED measurements. Since the CIE standardized rectangular-shape spectral response function for UV measurements cannot be realized with small spectral mismatch when using filtered detectors, the UV measurement errors can be several times ten percent or larger. The UV LEDs produce broadband radiation and both their peaks or spectral bandwidths can change significantly. The detectors used for the measurement of these LEDs also have different spectral bandwidths. In the discussed example, where LEDs with 365 nm peak are applied for fluorescent crack-recognition using liquid penetrant (non-destructive) inspection, the broadband radiometric LED (signal) measurement procedure is standardized. A UV LED irradiance-source was calibrated against an FEL lamp standard to determine its spectral irradiance. The spectral irradiance responsivity of a reference UV meter was also calibrated. The output signal of the reference UV meter was calculated from the spectral irradiance of the UV source and the spectral irradiance responsivity of the reference UV meter. From the output signal, both the integrated irradiance (in the reference plane of the reference meter) and the integrated responsivity of the reference meter were determined. Test UV meters calibrated for integrated responsivity against the reference UV meter, can be used to determine the integrated irradiance from a field UV source. The obtained 5 % (k=2) measurement uncertainty can be decreased when meters with spectral response close to a constant value are selected.

  17. Precision measurement of quasi-elastic transverse and longitudinal response functions in the range 0.55 GeV/c lte |q-right arrow| lte 1.0 GeV/c

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Atac, Hamza

    The Coulomb Sum is defined by the quasi-elastic nucleon knock-out process and it is the integration of the longitudinal response function over the energy loss of the incident electron. The Coulomb sum goes to the total charge at large q. The existing measurements of the Coulomb Sum Rule show disagreement with the theoretical calculations for the medium and heavy nuclei. To find the reason behind the disagreement might answer the question of whether the properties of the nucleons are affected by the nuclear medium or not. In order to determine the Coulomb Sum in nuclei, a precision measurement of inclusivemore » electron scattering in the quasi-elastic region was performed at the Thomas Jefferson National Accelerator Facility. Incident electrons with energies ranging from 0.4 GeV to 4 GeV scattered off 4He,12C,56Fe and 208Pb nuclei at four scattering angles (15 deg.; 60 deg.; 90 deg.; 120 deg.) and scattered energies ranging from 0.1 GeV to 4 GeV. The Born cross sections were extracted for the Left High Resolution Spectrometer (LHRS) and the Right High Resolution Spectrometer 56Fe data. The Rosenbluth separation was performed to extract the transverse and longitudinal response functions at 650 MeV three-momentum transfer. The preliminary results of the longitudinal and transverse functions were extracted for 56Fe target at 650 MeV three-momentum transfer.« less

  18. Trajectories of parasympathetic nervous system function before, during, and after feeding in infants with transposition of the great arteries.

    PubMed

    Harrison, Tondi M

    2011-01-01

    Compromised parasympathetic response to stressors may underlie feeding difficulties in infants with complex congenital heart defects, but little is known about the temporal pattern of parasympathetic response across phases of feeding. The aim of this study was to describe initial data exploration of trajectories of parasympathetic response to feeding in 15 infants with surgically corrected transposition of the great arteries and to explore the effects of feeding method, feeding skill, and maternal sensitivity on trajectories. In this descriptive, exploratory study, parasympathetic function was measured using high-frequency heart rate variability (HF HRV), feeding skill was measured using the Early Feeding Skills assessment, and maternal sensitivity was measured using the Parent-Child Early Relational Assessment. Data were collected before, during, and after feeding at 2 weeks and 2 months of age. Trajectories of parasympathetic function and relationships with possible contributing factors were examined graphically. Marked between-infant variability in HF HRV across phases of feeding was apparent at both ages, although it was attenuated at 2 months. Four patterns of HF HRV trajectories across phases of feeding were identified and associated with feeding method, feeding skill, and maternal sensitivity. Developmental increases in HF HRV were apparent in most breast-fed, but not bottle-fed, infants. This exploratory data analysis provides critical information in preparation for a larger study in which varying trajectories and potential contributing factors can be modeled in relationship to infant outcomes. Findings support inclusion of feeding method, feeding skill, and maternal sensitivity in modeling parasympathetic function across feeding.

  19. Trajectories of Parasympathetic Nervous System Function before, during, and after Feeding in Infants with Transposition of the Great Arteries

    PubMed Central

    Harrison, Tondi M.

    2011-01-01

    Background Compromised parasympathetic response to stressors may underlie feeding difficulties in infants with complex congenital heart defects, but little is known about the temporal pattern of parasympathetic response across phases of feeding. Objectives To describe initial data exploration of trajectories of parasympathetic response to feeding in 15 infants with surgically corrected transposition of the great arteries and to explore effects of feeding method, feeding skill, and maternal sensitivity on trajectories. Method In this descriptive, exploratory study, parasympathetic function was measured using high frequency heart rate variability (HF HRV), feeding skill was measured using the Early Feeding Skills assessment, and maternal sensitivity was measured using the Parent-Child Early Relational Assessment. Data were collected before, during, and after feeding at 2 weeks and 2 months of age. Trajectories of parasympathetic function and relationships with possible contributing factors were examined graphically. Results Marked between-infant variability in HF HRV across phases of feeding was apparent at both ages, although attenuated at 2 months. Four patterns of HF HRV trajectories across phases of feeding were identified and associated with feeding method, feeding skill, and maternal sensitivity. Developmental increases in HF HRV were apparent in most breastfed, but not bottle-fed, infants. Discussion This exploratory data analysis provided critical information in preparation for a larger study in which varying trajectories and potential contributing factors can be modeled in relationship to infant outcomes. Findings support inclusion of feeding method, feeding skill, and maternal sensitivity in modeling parasympathetic function across feeding. PMID:21543958

  20. Optical response of the sodium alanate system: GW0-BSE calculations and thin film measurements

    NASA Astrophysics Data System (ADS)

    van Setten, M. J.; Gremaud, R.; Brocks, G.; Dam, B.; Kresse, G.; de Wijs, G. A.

    2011-01-01

    We calculate from first principles the optical spectra of the hydrides in the sodium alanate hydrogen storage system: NaH, NaAlH4, and Na3AlH6. In particular we study the effects of systematic improvements of the theoretical description. To benchmark the calculations we also measure the optical response of a thin film of NaH. The simplest calculated dielectric functions are based upon independent electrons and holes, whose spectrum is obtained at the G0W0 level. Successive improvements consist of including partial self-consistency (so-called GW0) and account for excitonic effects, using the Bethe-Salpeter equation (BSE). Each improvement gives a sizable blue shift or red shift of the dielectric functions, but conserves the trend in the optical gap among different materials. Whereas these shifts partially cancel at the highest (GW0-BSE) level of approximation, the shape of the dielectric functions is strongly modified by excitonic effects. Calculations at the GW0-BSE level give a good agreement with the dielectric function of NaH extracted from the measurements. It demonstrates that the approach can be used for a quantitative interpretation of spectra in novel hydrogen storage materials obtained via, e.g., hydrogenography.

  1. Ethnic differences in macrovascular and microvascular function in systolic heart failure.

    PubMed

    Shantsila, Eduard; Wrigley, Benjamin; Shantsila, Alena; Tapp, Luke D; Blann, Andrew D; Gill, Paramjit S; Lip, Gregory Y H

    2011-11-01

    Endothelial dysfunction is implicated in the pathophysiological features of heart failure (HF), and ethnic differences in the presentation of cardiovascular disease are evident, with an excess seen among South Asians (SAs). However, data on ethnic differences in endothelial function in HF are limited. In a cross-sectional study, we recruited 128 subjects with systolic HF: 50 SAs, 50 whites, and 28 African Caribbeans (ACs). In addition, SAs with systolic HF were compared with 40 SAs with coronary artery disease without HF ("disease controls") and 40 SA healthy controls. Macrovascular endothelial function was assessed by measurement of flow-mediated dilation (FMD) in response to hyperemia, arterial stiffness was assessed by the pulse-wave velocity, and microvascular endothelial function was assessed by forearm laser Doppler flowmetry. CD144-expressing endothelial microparticles were measured by flow cytometry. When compared with disease controls and healthy controls, SAs with HF had an impaired microvascular response to acetylcholine (P=0.001) and reduced FMD (P<0.001). In comparing ethnic groups, SAs with HF had an impaired response to acetylcholine (123±95.5%) compared with whites (258±156%) and ACs (286±173%, P<0.001 for both). Whites had a higher FMD (8.49±4.63%) than SAs (4.76±4.78%, P<0.001) and ACs (4.55±3.56%, P=0.01). No difference in endothelial-independent response was observed between study groups or in pulse-wave velocity. Ethnicity remained associated with microvascular endothelial function even after adjustment for age, presence of hypertension and diabetes mellitus, blood pressure, and glucose levels (P=0.003). There were no differences in numbers of endothelial microparticles. The SAs with HF have impaired microvascular and macrovascular endothelial function but preserved arterial elastic properties. Significant ethnic differences in endothelial function are evident in subjects with HF, with ethnicity being associated with microvascular endothelial dysfunction in this disorder.

  2. Response of space shuttle insulation panels to acoustic noise pressure

    NASA Technical Reports Server (NTRS)

    Vaicaitis, R.

    1976-01-01

    The response of reusable space shuttle insulation panels to random acoustic pressure fields are studied. The basic analytical approach in formulating the governing equations of motion uses a Rayleigh-Ritz technique. The input pressure field is modeled as a stationary Gaussian random process for which the cross-spectral density function is known empirically from experimental measurements. The response calculations are performed in both frequency and time domain.

  3. Expanding specificity of class 1 restricted CD8+ T cells for viral epitopes following multiple inoculations of swine with a human adenivorus vectored foot-and-mouth disease virus (FMDV) vaccine

    USDA-ARS?s Scientific Manuscript database

    The immune response to the highly acute foot-and-mouth disease virus (FMDV) is routinely reported as a measure of serum antibody. However, a critical effector function of immune responses combating viral infection of mammals is the cytotoxic T lymphocyte (CTL) response, mediated by virus specific ...

  4. The pre-launch characterization of SIMBIO-SYS/VIHI imaging spectrometer for the BepiColombo mission to Mercury. I. Linearity, radiometry, and geometry calibrations.

    PubMed

    Filacchione, Gianrico; Capaccioni, Fabrizio; Altieri, Francesca; Carli, Cristian; Ficai Veltroni, Iacopo; Dami, Michele; Tommasi, Leonardo; Aroldi, Gianluca; Borrelli, Donato; Barbis, Alessandra; Baroni, Marco; Pastorini, Guia; Mugnuolo, Raffaele

    2017-09-01

    Before integration aboard European Space Agency BepiColombo mission to Mercury, the visible and near infrared hyperspectral imager underwent an intensive calibration campaign. We report in Paper I about the radiometric and linearity responses of the instrument including the optical setups used to perform them. Paper II [F. Altieri et al., Rev. Sci. Instrum. 88, 094503 (2017)] will describe complementary spectral response calibration. The responsivity is used to calculate the expected instrumental signal-to-noise ratio for typical observation scenarios of the BepiColombo mission around Mercury. A description is provided of the internal calibration unit that will be used to verify the relative response during the instrument's lifetime. The instrumental spatial response functions as measured along and across the spectrometer's slit direction were determined by means of spatial scans performed with illuminated test slits placed at the focus of a collimator. The dedicated optical setup used for these measurements is described together with the methods used to derive the instrumental spatial responses at different positions within the 3.5 ° field of view and at different wavelengths in the 0.4-2.0 μm spectral range. Finally, instrument imaging capabilities and Modulated Transfer Function are tested by using a standard mask as a target.

  5. Assessment of the psychometric properties of the Short-Form Prolapse/Urinary Incontinence Sexual Questionnaire (PISQ-12) following surgical placement of Prolift+M: a transvaginal partially absorbable mesh system for the treatment of pelvic organ prolapse.

    PubMed

    Roy, Sanjoy; Mohandas, Anita; Coyne, Karin; Gelhorn, Heather; Gauld, Judi; Sikirica, Vanja; Milani, Alfredo L

    2012-04-01

    Impairment of sexual function is a significant problem among women suffering from pelvic organ prolapse (POP). Because anatomical measures of POP do not always correspond with patients' subjective reports of their condition, patient-reported outcome measures may provide additional valuable information regarding the experiences of women who have undergone surgery. The Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire (PISQ-12) is a validated, widely used condition-specific questionnaire focused on sexual function among patients with POP or urinary incontinence. This study aims to report sexual function outcomes as measured by PISQ-12 and to evaluate the psychometric characteristics of the questionnaire following surgical mesh implant for the treatment of POP. The PISQ-12 was used to measure sexual function, while a set of other measures, namely, Pelvic Organ Prolapse Quantification, Patient Global Impression of Change, Pelvic Floor Distress Inventory, Pelvic Floor Impact Questionnaire, and Surgical Satisfaction Questionnaire, was used for validation. Data for the study were collected from a prospective multicenter, single-arm study of surgical POP repair via the transvaginal placement of a partially absorbable mesh system. For baseline, month 3, and month 12 following POP surgery, several psychometric properties of the PISQ-12 were evaluated, including internal consistency (Cronbach's alpha), concurrent validity, discriminant validity, and responsiveness. As measured by the PISQ-12 questionnaire, statistically significant improvements were observed in the composite summary score as well as all three subscale scores at 1 year. The PISQ-12 generally demonstrated good psychometric properties including internal consistency reliability, validity, and responsiveness. The PISQ-12 items had good distributional properties at baseline, with substantial ceiling effects at follow-up visits reflecting improvements experienced by the patients. The PISQ-12 is a valid measure of sexual function in studies involving patients with POP. © 2012 International Society for Sexual Medicine.

  6. Quantitative analysis of random migration of cells using time-lapse video microscopy.

    PubMed

    Jain, Prachi; Worthylake, Rebecca A; Alahari, Suresh K

    2012-05-13

    Cell migration is a dynamic process, which is important for embryonic development, tissue repair, immune system function, and tumor invasion (1, 2). During directional migration, cells move rapidly in response to an extracellular chemotactic signal, or in response to intrinsic cues (3) provided by the basic motility machinery. Random migration occurs when a cell possesses low intrinsic directionality, allowing the cells to explore their local environment. Cell migration is a complex process, in the initial response cell undergoes polarization and extends protrusions in the direction of migration (2). Traditional methods to measure migration such as the Boyden chamber migration assay is an easy method to measure chemotaxis in vitro, which allows measuring migration as an end point result. However, this approach neither allows measurement of individual migration parameters, nor does it allow to visualization of morphological changes that cell undergoes during migration. Here, we present a method that allows us to monitor migrating cells in real time using video - time lapse microscopy. Since cell migration and invasion are hallmarks of cancer, this method will be applicable in studying cancer cell migration and invasion in vitro. Random migration of platelets has been considered as one of the parameters of platelet function (4), hence this method could also be helpful in studying platelet functions. This assay has the advantage of being rapid, reliable, reproducible, and does not require optimization of cell numbers. In order to maintain physiologically suitable conditions for cells, the microscope is equipped with CO(2) supply and temperature thermostat. Cell movement is monitored by taking pictures using a camera fitted to the microscope at regular intervals. Cell migration can be calculated by measuring average speed and average displacement, which is calculated by Slidebook software.

  7. A Chemiluminescence Detector for Ozone Measurement.

    ERIC Educational Resources Information Center

    Carroll, H.; And Others

    An ozone detector was built and evaluated for its applicability in smog chamber studies. The detection method is based on reaction of ozone with ethylene and measurement of resultant chemiluminescence. In the first phase of evaluation, the detector's response to ozone was studied as a function of several instrument parameters, and optimum…

  8. Myth 5: Creativity Is Too Difficult to Measure

    ERIC Educational Resources Information Center

    Treffinger, Donald J.

    2009-01-01

    In his 1982 response to the myth that "creativity is too difficult to measure," Dr. Joe Khatena (a long-time contributor to the literature on creativity), characterized creativity as the "most exciting dimension of mental functioning." Building on a three-dimensional view of creativity (emphasizing the "individual," the "environment," and the…

  9. Analysis of complex samples using a portable multi-wavelength light emitting diode (LED) fluorescence spectrometer

    USDA-ARS?s Scientific Manuscript database

    Spectroscopic analysis of chemically complex samples often requires an increase n the dimensionality of the measured response surface. This often involves the measurement of emitted light intensities as functions of both wavelengths of excitation and emission resulting in the generation of an excita...

  10. Computer-Aided Instruction in Automated Instrumentation.

    ERIC Educational Resources Information Center

    Stephenson, David T.

    1986-01-01

    Discusses functions of automated instrumentation systems, i.e., systems which combine electrical measuring instruments and a controlling computer to measure responses of a unit under test. The computer-assisted tutorial then described is programmed for use on such a system--a modern microwave spectrum analyzer--to introduce engineering students to…

  11. Three Classes of Nonparametric Differential Step Functioning Effect Estimators

    ERIC Educational Resources Information Center

    Penfield, Randall D.

    2008-01-01

    The examination of measurement invariance in polytomous items is complicated by the possibility that the magnitude and sign of lack of invariance may vary across the steps underlying the set of polytomous response options, a concept referred to as differential step functioning (DSF). This article describes three classes of nonparametric DSF effect…

  12. Reduced Prefrontal Hemodynamic Response in Pediatric Obsessive-Compulsive Disorder as Measured by Near-Infrared Spectroscopy

    ERIC Educational Resources Information Center

    Ota, Toyosaku; Iida, Junzo; Sawada, Masayuki; Suehiro, Yuko; Yamamuro, Kazuhiko; Matsuura, Hiroki; Tanaka, Shohei; Kishimoto, Naoko; Negoro, Hideki; Kishimoto, Toshifumi

    2013-01-01

    Recent developments in near-infrared spectroscopy (NIRS) have enabled non-invasive clarification of brain functions in psychiatric disorders. Functional neuroimaging studies of patients with obsessive-compulsive disorder (OCD) have suggested that the frontal cortex and subcortical structures may play a role in the pathophysiology of the disorder.…

  13. A Double-Blind Atropine Trial for Active Learning of Autonomic Function

    ERIC Educational Resources Information Center

    Fry, Jeffrey R.; Burr, Steven A.

    2011-01-01

    Here, we describe a human physiology laboratory class measuring changes in autonomic function over time in response to atropine. Students use themselves as subjects, generating ownership and self-interest in the learning as well as directly experiencing the active link between physiology and pharmacology in people. The class is designed to…

  14. Brain response to masked and unmasked facial emotions as a function of implicit and explicit personality self-concept of extraversion.

    PubMed

    Suslow, Thomas; Kugel, Harald; Lindner, Christian; Dannlowski, Udo; Egloff, Boris

    2017-01-06

    Extraversion-introversion is a personality dimension referring to individual differences in social behavior. In the past, neurobiological research on extraversion was almost entirely based upon questionnaires which inform about the explicit self-concept. Today, indirect measures are available that tap into the implicit self-concept of extraversion which is assumed to result from automatic processing functions. In our study, brain activation while viewing facial expression of affiliation relevant (i.e., happiness, and disgust) and irrelevant (i.e., fear) emotions was examined as a function of the implicit and explicit self-concept of extraversion and processing mode (automatic vs. controlled). 40 healthy volunteers watched blocks of masked and unmasked emotional faces while undergoing functional magnetic resonance imaging. The Implicit Association Test and the NEO Five-Factor Inventory were applied as implicit and explicit measures of extraversion which were uncorrelated in our sample. Implicit extraversion was found to be positively associated with neural response to masked happy faces in the thalamus and temporo-parietal regions and to masked disgust faces in cerebellar areas. Moreover, it was positively correlated with brain response to unmasked disgust faces in the amygdala and cortical areas. Explicit extraversion was not related to brain response to facial emotions when controlling trait anxiety. The implicit compared to the explicit self-concept of extraversion seems to be more strongly associated with brain activation not only during automatic but also during controlled processing of affiliation relevant facial emotions. Enhanced neural response to facial disgust could reflect high sensitivity to signals of interpersonal rejection in extraverts (i.e., individuals with affiliative tendencies). Copyright © 2016 IBRO. Published by Elsevier Ltd. All rights reserved.

  15. Effect of Urea and Thiourea on Generation of Xenogeneic Extracellular Matrix Scaffolds for Tissue Engineering

    PubMed Central

    Wong, Maelene L.; Wong, Janelle L.; Horn, Rebecca M.; Sannajust, Kimberley C.; Rice, Dawn A.

    2016-01-01

    Effective solubilization of proteins by chaotropes in proteomic applications motivates their use in solubilization-based antigen removal/decellularization strategies. A high urea concentration has previously been reported to significantly reduce lipophilic antigen content of bovine pericardium (BP); however, structure and function of the resultant extracellular matrix (ECM) scaffold were compromised. It has been recently demonstrated that in vivo ECM scaffold fate is determined by two primary outcome measures as follows: (1) sufficient reduction in antigen content to avoid graft-specific adaptive immune responses and (2) maintenance of native ECM structural proteins to avoid graft-specific innate responses. In this work, we assessed residual antigenicity, ECM architecture, ECM content, thermal stability, and tensile properties of BP subjected to a gradient of urea concentrations to determine whether an intermediate concentration exists at which both antigenicity and structure–function primary outcome measures for successful in vivo scaffold outcome can simultaneously be achieved. Alteration in tissue structure–function properties at various urea concentrations with decreased effectiveness for antigen removal makes use of urea-mediated antigen removal unlikely to be suitable for functional scaffold generation. PMID:27230226

  16. Cortical Signal Analysis and Advances in Functional Near-Infrared Spectroscopy Signal: A Review.

    PubMed

    Kamran, Muhammad A; Mannan, Malik M Naeem; Jeong, Myung Yung

    2016-01-01

    Functional near-infrared spectroscopy (fNIRS) is a non-invasive neuroimaging modality that measures the concentration changes of oxy-hemoglobin (HbO) and de-oxy hemoglobin (HbR) at the same time. It is an emerging cortical imaging modality with a good temporal resolution that is acceptable for brain-computer interface applications. Researchers have developed several methods in last two decades to extract the neuronal activation related waveform from the observed fNIRS time series. But still there is no standard method for analysis of fNIRS data. This article presents a brief review of existing methodologies to model and analyze the activation signal. The purpose of this review article is to give a general overview of variety of existing methodologies to extract useful information from measured fNIRS data including pre-processing steps, effects of differential path length factor (DPF), variations and attributes of hemodynamic response function (HRF), extraction of evoked response, removal of physiological noises, instrumentation, and environmental noises and resting/activation state functional connectivity. Finally, the challenges in the analysis of fNIRS signal are summarized.

  17. Cortical Signal Analysis and Advances in Functional Near-Infrared Spectroscopy Signal: A Review

    PubMed Central

    Kamran, Muhammad A.; Mannan, Malik M. Naeem; Jeong, Myung Yung

    2016-01-01

    Functional near-infrared spectroscopy (fNIRS) is a non-invasive neuroimaging modality that measures the concentration changes of oxy-hemoglobin (HbO) and de-oxy hemoglobin (HbR) at the same time. It is an emerging cortical imaging modality with a good temporal resolution that is acceptable for brain-computer interface applications. Researchers have developed several methods in last two decades to extract the neuronal activation related waveform from the observed fNIRS time series. But still there is no standard method for analysis of fNIRS data. This article presents a brief review of existing methodologies to model and analyze the activation signal. The purpose of this review article is to give a general overview of variety of existing methodologies to extract useful information from measured fNIRS data including pre-processing steps, effects of differential path length factor (DPF), variations and attributes of hemodynamic response function (HRF), extraction of evoked response, removal of physiological noises, instrumentation, and environmental noises and resting/activation state functional connectivity. Finally, the challenges in the analysis of fNIRS signal are summarized. PMID:27375458

  18. Structural and Acoustic Numerical Modeling of a Curved Composite Honeycomb Panel

    NASA Technical Reports Server (NTRS)

    Grosveld, Ferdinand W.; Buehrle, Ralph D.; Robinson, Jay H.

    2001-01-01

    The finite and boundary element modeling of the curved section of a composite honeycomb aircraft fuselage sidewall was validated for both structural response and acoustic radiation. The curved panel was modeled in the pre-processor MSC/PATRAN. Geometry models of the curved panel were constructed based on the physical dimensions of the test article. Material properties were obtained from the panel manufacturer. Finite element models were developed to predict the modal parameters for free and supported panel boundary conditions up to a frequency of 600 Hz. Free boundary conditions were simulated by providing soft foam support under the four comers of the panel or by suspending the panel from elastic bands. Supported boundary conditions were obtained by clamping the panel between plastic tubing seated in grooves along the perimeter of a stiff and heavy frame. The frame was installed in the transmission loss window of the Structural Acoustic Loads and Transmission (SALT) facility at NASA Langley Research Center. The structural response of the curved panel due to point force excitation was predicted using MSC/NASTRAN and the radiated sound was computed with COMET/Acoustics. The predictions were compared with the results from experimental modal surveys and forced response tests on the fuselage panel. The finite element models were refined and updated to provide optimum comparison with the measured modal data. Excellent agreement was obtained between the numerical and experimental modal data for the free as well as for the supported boundary conditions. Frequency response functions (FRF) were computed relating the input force excitation at one panel location to the surface acceleration response at five panel locations. Frequency response functions were measured at the same locations on the test specimen and were compared with the calculated FRF values. Good agreement was obtained for the real and imaginary parts of the transfer functions when modal participation was allowed up to 3000 Hz. The validated finite element model was used to predict the surface velocities due to the point force excitation. Good agreement was obtained between the spatial characteristics of the predicted and measured surface velocities. The measured velocity data were input into the acoustic boundary element code to compute the sound radiated by the panel. The predicted sound pressure levels in the far-field of the panel agreed well with the sound pressure levels measured at the same location.

  19. Obesity, Cardiovascular Fitness, and Inhibition Function: An Electrophysiological Study

    PubMed Central

    Song, Tai-Fen; Chi, Lin; Chu, Chien-Heng; Chen, Feng-Tzu; Zhou, Chenglin; Chang, Yu-Kai

    2016-01-01

    The purpose of the present study was to examine how obesity and cardiovascular fitness are associated with the inhibition aspect of executive function from behavioral and electrophysiological perspectives. One hundred college students, aged 18–25 years, were categorized into four groups of equal size on the basis of body mass index and cardiovascular fitness: a normal-weight and high-fitness (NH) group, an obese-weight and high-fitness (OH) group, a normal-weight and low-fitness (NL) group, and an obese-weight and low-fitness (OL) group. Behavioral measures of response time and number of errors, as well as event-related potential measures of P3 and N1, were assessed during the Stroop Task. The results revealed that, in general, the NH group exhibited shorter response times and larger P3 amplitudes relative to the NL and OL groups, wherein the OL group exhibited the longest response time in the incongruent condition. No group differences in N1 indices were also revealed. These findings suggest that the status of being both normal weight and having high cardiovascular fitness is associated with better behavioral and later stages of electrophysiological indices of cognitive function. PMID:27512383

  20. Comparison of bandwidths in the inferior colliculus and the auditory nerve. II: Measurement using a temporally manipulated stimulus.

    PubMed

    Mc Laughlin, Myles; Chabwine, Joelle Nsimire; van der Heijden, Marcel; Joris, Philip X

    2008-10-01

    To localize low-frequency sounds, humans rely on an interaural comparison of the temporally encoded sound waveform after peripheral filtering. This process can be compared with cross-correlation. For a broadband stimulus, after filtering, the correlation function has a damped oscillatory shape where the periodicity reflects the filter's center frequency and the damping reflects the bandwidth (BW). The physiological equivalent of the correlation function is the noise delay (ND) function, which is obtained from binaural cells by measuring response rate to broadband noise with varying interaural time delays (ITDs). For monaural neurons, delay functions are obtained by counting coincidences for varying delays across spike trains obtained to the same stimulus. Previously, we showed that BWs in monaural and binaural neurons were similar. However, earlier work showed that the damping of delay functions differs significantly between these two populations. Here, we address this paradox by looking at the role of sensitivity to changes in interaural correlation. We measured delay and correlation functions in the cat inferior colliculus (IC) and auditory nerve (AN). We find that, at a population level, AN and IC neurons with similar characteristic frequencies (CF) and BWs can have different responses to changes in correlation. Notably, binaural neurons often show compression, which is not found in the AN and which makes the shape of delay functions more invariant with CF at the level of the IC than at the AN. We conclude that binaural sensitivity is more dependent on correlation sensitivity than has hitherto been appreciated and that the mechanisms underlying correlation sensitivity should be addressed in future studies.

Top