Sample records for measured values reported

  1. Measuring changes in lipid and blood glucose values in the health and wellness program of Prudential Financial, Inc.

    PubMed

    Short, Meghan E; Goetzel, Ron Z; Young, Jared S; Kowlessar, Niranjana M; Liss-Levinson, Rivka C; Tabrizi, Maryam J; Roemer, Enid Chung; Sabatelli, Adriano A; Winick, Keith; Montes, Myrtho; Crighton, K Andrew

    2010-08-01

    To determine the effect of health promotion programs of Prudential Financial, Inc on biometric measures of blood lipids and glucose. Using actual biometric and self-reported measures of blood lipids and glucose values for the employees of Prudential Financial, Inc, we examined 1) the extent to which self-reported lipid and blood glucose values correlate to laboratory data, 2) whether self-reported and measured lipid values differ for physically active and sedentary employees, and 3) whether participation in a disease management program affects employees' lipid measures. We found significant differences in self-reported and measured total cholesterol and low-density lipoprotein values, although these differences and those for all lipid and blood glucose values were not clinically meaningful. Supporting previous clinical studies, high-density lipoprotein values were significantly higher for fitness center users compared with sedentary employees. Finally, disease management participants showed a significant reduction in total cholesterol and low-density lipoprotein during a 3-year period compared with nonparticipants. On average, the employees of Prudential Financial, Inc were aware of and accurately reported their lipid and blood glucose levels. Results from this study support the value of evaluating corporate health promotion programs, using measured biometric outcomes.

  2. Measuring Value in Internal Medicine Residency Training Hospitals Using Publicly Reported Measures.

    PubMed

    Schickedanz, Adam; Gupta, Reshma; Arora, Vineet M; Braddock, Clarence H

    2018-03-01

    Graduate medical education (GME) lacks measures of resident preparation for high-quality, cost-conscious practice. The authors used publicly reported teaching hospital value measures to compare internal medicine residency programs on high-value care training and to validate these measures against program director perceptions of value. Program-level value training scores were constructed using Centers for Medicare & Medicaid Services Value-Based Purchasing (VBP) Program hospital quality and cost-efficiency data. Correlations with Association of Program Directors in Internal Medicine Annual Survey high-value care training measures were examined using logistic regression. For every point increase in program-level VBP score, residency directors were more likely to agree that GME programs have a responsibility to contain health care costs (adjusted odds ratio [aOR] 1.18, P = .04), their faculty model high-value care (aOR 1.07, P = .03), and residents are prepared to make high-value medical decisions (aOR 1.07, P = .09). Publicly reported clinical data offer valid measures of GME value training.

  3. Accuracy and usefulness of BMI measures based on self-reported weight and height: findings from the NHANES & NHIS 2001-2006.

    PubMed

    Stommel, Manfred; Schoenborn, Charlotte A

    2009-11-19

    The Body Mass Index (BMI) based on self-reported height and weight ("self-reported BMI") in epidemiologic studies is subject to measurement error. However, because of the ease and efficiency in gathering height and weight information through interviews, it remains important to assess the extent of error present in self-reported BMI measures and to explore possible adjustment factors as well as valid uses of such self-reported measures. Using the combined 2001-2006 data from the continuous National Health and Nutrition Examination Survey, discrepancies between BMI measures based on self-reported and physical height and weight measures are estimated and socio-demographic predictors of such discrepancies are identified. Employing adjustments derived from the socio-demographic predictors, the self-reported measures of height and weight in the 2001-2006 National Health Interview Survey are used for population estimates of overweight & obesity as well as the prediction of health risks associated with large BMI values. The analysis relies on two-way frequency tables as well as linear and logistic regression models. All point and variance estimates take into account the complex survey design of the studies involved. Self-reported BMI values tend to overestimate measured BMI values at the low end of the BMI scale (< 22) and underestimate BMI values at the high end, particularly at values > 28. The discrepancies also vary systematically with age (younger and older respondents underestimate their BMI more than respondents aged 42-55), gender and the ethnic/racial background of the respondents. BMI scores, adjusted for socio-demographic characteristics of the respondents, tend to narrow, but do not eliminate misclassification of obese people as merely overweight, but health risk estimates associated with variations in BMI values are virtually the same, whether based on self-report or measured BMI values. BMI values based on self-reported height and weight, if corrected for biases associated with socio-demographic characteristics of the survey respondents, can be used to estimate health risks associated with variations in BMI, particularly when using parametric prediction models.

  4. Design of Value-Added Models for IMPACT and TEAM in DC Public Schools, 2010-2011 School Year. Final Report

    ERIC Educational Resources Information Center

    Isenberg, Eric; Hock, Heinrich

    2011-01-01

    This report presents the value-added models that will be used to measure school and teacher effectiveness in the District of Columbia Public Schools (DCPS) in the 2010-2011 school year. It updates the earlier technical report, "Measuring Value Added for IMPACT and TEAM in DC Public Schools." The earlier report described the methods used…

  5. Validity of parent-reported weight and height of preschool children measured at home or estimated without home measurement: a validation study

    PubMed Central

    2011-01-01

    Background Parental reports are often used in large-scale surveys to assess children's body mass index (BMI). Therefore, it is important to know to what extent these parental reports are valid and whether it makes a difference if the parents measured their children's weight and height at home or whether they simply estimated these values. The aim of this study is to compare the validity of parent-reported height, weight and BMI values of preschool children (3-7 y-old), when measured at home or estimated by parents without actual measurement. Methods The subjects were 297 Belgian preschool children (52.9% male). Participation rate was 73%. A questionnaire including questions about height and weight of the children was completed by the parents. Nurses measured height and weight following standardised procedures. International age- and sex-specific BMI cut-off values were employed to determine categories of weight status and obesity. Results On the group level, no important differences in accuracy of reported height, weight and BMI were identified between parent-measured or estimated values. However, for all 3 parameters, the correlations between parental reports and nurse measurements were higher in the group of children whose body dimensions were measured by the parents. Sensitivity for underweight and overweight/obesity were respectively 73% and 47% when parents measured their child's height and weight, and 55% and 47% when parents estimated values without measurement. Specificity for underweight and overweight/obesity were respectively 82% and 97% when parents measured the children, and 75% and 93% with parent estimations. Conclusions Diagnostic measures were more accurate when parents measured their child's weight and height at home than when those dimensions were based on parental judgements. When parent-reported data on an individual level is used, the accuracy could be improved by encouraging the parents to measure weight and height of their children at home. PMID:21736757

  6. Clinical tooth preparations and associated measuring methods: a systematic review.

    PubMed

    Tiu, Janine; Al-Amleh, Basil; Waddell, J Neil; Duncan, Warwick J

    2015-03-01

    The geometries of tooth preparations are important features that aid in the retention and resistance of cemented complete crowns. The clinically relevant values and the methods used to measure these are not clear. The purpose of this systematic review was to retrieve, organize, and critically appraise studies measuring clinical tooth preparation parameters, specifically the methodology used to measure the preparation geometry. A database search was performed in Scopus, PubMed, and ScienceDirect with an additional hand search on December 5, 2013. The articles were screened for inclusion and exclusion criteria and information regarding the total occlusal convergence (TOC) angle, margin design, and associated measuring methods were extracted. The values and associated measuring methods were tabulated. A total of 1006 publications were initially retrieved. After removing duplicates and filtering by using exclusion and inclusion criteria, 983 articles were excluded. Twenty-three articles reported clinical tooth preparation values. Twenty articles reported the TOC, 4 articles reported margin designs, 4 articles reported margin angles, and 3 articles reported the abutment height of preparations. A variety of methods were used to measure these parameters. TOC values seem to be the most important preparation parameter. Recommended TOC values have increased over the past 4 decades from an unachievable 2- to 5-degree taper to a more realistic 10 to 22 degrees. Recommended values are more likely to be achieved under experimental conditions if crown preparations are performed outside of the mouth. We recommend that a standardized measurement method based on the cross sections of crown preparations and standardized reporting be developed for future studies analyzing preparation geometry. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  7. The incremental value of self-reported mental health measures in predicting functional outcomes of veterans.

    PubMed

    Eisen, Susan V; Bottonari, Kathryn A; Glickman, Mark E; Spiro, Avron; Schultz, Mark R; Herz, Lawrence; Rosenheck, Robert; Rofman, Ethan S

    2011-04-01

    Research on patient-centered care supports use of patient/consumer self-report measures in monitoring health outcomes. This study examined the incremental value of self-report mental health measures relative to a clinician-rated measure in predicting functional outcomes among mental health service recipients. Participants (n = 446) completed the Behavior and Symptom Identification Scale, the Brief Symptom Inventory, and the Veterans/Rand Short Form-36 at enrollment in the study (T1) and 3 months later (T2). Global Assessment of Functioning (GAF) ratings, mental health service utilization, and psychiatric diagnoses were obtained from administrative data files. Controlling for demographic and clinical variables, results indicated that improvement based on the self-report measures significantly predicted one or more functional outcomes (i.e., decreased likelihood of post-enrollment psychiatric hospitalization and increased likelihood of paid employment), above and beyond the predictive value of the GAF. Inclusion of self-report measures may be a useful addition to performance measurement efforts.

  8. The accuracy of parent-reported height and weight for 6-12 year old U.S. children.

    PubMed

    Wright, Davene R; Glanz, Karen; Colburn, Trina; Robson, Shannon M; Saelens, Brian E

    2018-02-12

    Previous studies have examined correlations between BMI calculated using parent-reported and directly-measured child height and weight. The objective of this study was to validate correction factors for parent-reported child measurements. Concordance between parent-reported and investigator measured child height, weight, and BMI (kg/m 2 ) among participants in the Neighborhood Impact on Kids Study (n = 616) was examined using the Lin coefficient, where a value of ±1.0 indicates perfect concordance and a value of zero denotes non-concordance. A correction model for parent-reported height, weight, and BMI based on commonly collected demographic information was developed using 75% of the sample. This model was used to estimate corrected measures for the remaining 25% of the sample and measured concordance between correct parent-reported and investigator-measured values. Accuracy of corrected values in classifying children as overweight/obese was assessed by sensitivity and specificity. Concordance between parent-reported and measured height, weight and BMI was low (0.007, - 0.039, and - 0.005 respectively). Concordance in the corrected test samples improved to 0.752 for height, 0.616 for weight, and 0.227 for BMI. Sensitivity of corrected parent-reported measures for predicting overweight and obesity among children in the test sample decreased from 42.8 to 25.6% while specificity improved from 79.5 to 88.6%. Correction factors improved concordance for height and weight but did not improve the sensitivity of parent-reported measures for measuring child overweight and obesity. Future research should be conducted using larger and more nationally-representative samples that allow researchers to fully explore demographic variance in correction coefficients.

  9. Measuring the accuracy of self-reported height and weight in a community-based sample of young people

    PubMed Central

    2012-01-01

    Background Self-reported anthropometric data are commonly used to estimate prevalence of obesity in population and community-based studies. We aim to: 1) Determine whether survey participants are able and willing to self-report height and weight; 2) Assess the accuracy of self-reported compared to measured anthropometric data in a community-based sample of young people. Methods Participants (16–29 years) of a behaviour survey, recruited at a Melbourne music festival (January 2011), were asked to self-report height and weight; researchers independently weighed and measured a sub-sample. Body Mass Index was calculated and overweight/obesity classified as ≥25kg/m2. Differences between measured and self-reported values were assessed using paired t-test/Wilcoxon signed ranks test. Accurate report of height and weight were defined as <2cm and <2kg difference between self-report and measured values, respectively. Agreement between classification of overweight/obesity by self-report and measured values was assessed using McNemar’s test. Results Of 1405 survey participants, 82% of males and 72% of females self-reported their height and weight. Among 67 participants who were also independently measured, self-reported height and weight were significantly less than measured height (p=0.01) and weight (p<0.01) among females, but no differences were detected among males. Overall, 52% accurately self-reported height, 30% under-reported, and 18% over-reported; 34% accurately self-reported weight, 52% under-reported and 13% over-reported. More females (70%) than males (35%) under-reported weight (p=0.01). Prevalence of overweight/obesity was 33% based on self-report data and 39% based on measured data (p=0.16). Conclusions Self-reported measurements may underestimate weight but accurately identified overweight/obesity in the majority of this sample of young people. PMID:23170838

  10. Reporting of nitrogen-isotope abundances (Technical Report)

    USGS Publications Warehouse

    Coplen, Tyler B.; Krouse, H.R.; Böhlke, John Karl

    1992-01-01

    To eliminate possible confusion in the reporting of nitrogen-isotope analyses, the Commission on Atomic Weights and Isotopic Abundances recommends that the value 272 be employed for the 14N/15N value of N2 in air for calculating atom percent 15N from measured δ15N values.

  11. A Scaled-Projective Measure of Interpersonal Values

    ERIC Educational Resources Information Center

    Kilmann, Ralph H.

    1975-01-01

    The Kilmann Insight Test is a measure of the interpersonal value constructs. That is how the individual perceives and interprets the desirable and undesirable features of interpersonal behavior. The validity of the test is investigated by explaining its relationship to a self-report measure assessing similar values. (DEP)

  12. SU-E-J-19: An Intra-Institutional Study of Cone-Beam CT Dose for Image-Guided Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knutson, N; Present Address: Mount Sinai Roosevelt Hospital, New York, NY; Rankine, L

    2015-06-15

    Purpose: To determine the variability of Cone-Beam CT Dose Index (CB-CTDI) across multiple on-board imaging (OBI) systems within a single institution, and compare this to manufacturer provided data. Methods: The CB-CTDI was measured on three Trilogy and three TrueBeam Varian OBI systems, for six different clinically used scan protocols. Measurements were taken using a 10 cm long CT ionization chamber in either a 16 cm (head-simulating) or 32 cm (body-simulating) diameter, acrylic, cylindrical, 15 cm long CTDI phantom. We assessed the variation in CB-CTDI between the OBI systems and compared our measured values to the data provided by the manufacturer.more » Results: The standard error in the CB-CTDI measured for all protocols was found to be within ±2% and ±5% of the mean for TrueBeam and Trilogy, respectively. For all head scan protocols, the measured TrueBeam values were lower than the manufacturer’s reported values, with a maximum difference of 13.9% and an average difference of 11%. For the body scan protocols, the TrueBeam measured values were 3% and 13% greater than the manufacturer’s reported values for two out of three protocols, and 38% lower than reported for the third protocol. In total, 7/18 CB-CTDI measurements fell within the manufacturers specified range (±10%). Across all scans the Truebeam machines were found to have a lower CB-CTDI than Trilogy, particularly the head scan protocols, which show decreases of up to 30% . Conclusion: The intra-institutional variation of CB-CTDI was found to be clinically acceptable at less than 5%. For the TrueBeam OBI system, over half of the measured scans failed to fall with in the manufactured quoted range of 10%, however, all measured values were within 15% of the manufacturer’s reported values. For accurate assessment and reporting of imaging dose to radiotherapy patients, our results indicate a need for standardization in CB-CTDI measurement technique.« less

  13. Libet's experiment: Questioning the validity of measuring the urge to move.

    PubMed

    Dominik, Tomáš; Dostál, Daniel; Zielina, Martin; Šmahaj, Jan; Sedláčková, Zuzana; Procházka, Roman

    2017-03-01

    The time of subjectively registered urge to move (W) constituted the central point of most Libet-style experiments. It is therefore crucial to verify the W validity. Our experiment was based on the assumption that the W time is inferred, rather than introspectively perceived. We used the rotating spot method to gather the W reports together with the reports of the subjective timing of actual movement (M). The subjects were assigned the tasks in two different orders. When measured as first in the respective session, no significant difference between W and M values was found, which suggests that uninformed subjects tend to confuse W for M reports. Moreover, we found that W values measured after the M task were significantly earlier than W values measured before M. This phenomenon suggests that the apparent difference between W and M values is in fact caused by the subjects' previous experience with M measurements. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. 40 CFR 87.64 - Sampling and analytical procedures for measuring gaseous exhaust emissions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .../kilonewton rO. (c) Report CO2 by calculation from fuel mass flow rate measurements in Appendices 3 and 5 to... 1, 2011, report CO2 values along with your emission levels of regulated NOX to the Administrator for... on or after January 1, 2011. By January 1, 2011, report CO2 values along with your emission levels of...

  15. Accuracy of Self-Reported Physical Activity Levels in Obese Adolescents

    PubMed Central

    Elliott, Sarah A.; Baxter, Kimberley A.; Davies, Peter S. W.; Truby, Helen

    2014-01-01

    Introduction. Self-reported measures of habitual physical activity rely completely on the respondent's ability to provide accurate information on their own physical activity behaviours. Our aim was to investigate if obese adolescents could accurately report their physical activity levels (PAL) using self-reported diaries. Methods. Total energy expenditure (TEE) was measured using doubly labelled water (DLW) and resting energy expenditure (REE) was measured via indirect calorimetry. Activity energy expenditure (AEE) and PAL values were derived from measured TEE and REE. Self-reported, four-day activity diaries were used to calculate daily MET values and averaged to give an estimated PAL value (ePAL). Results. Twenty-two obese adolescents, mean age 13.2 ± 1.8 years, mean BMI 31.3 ± 4.6 kg/m2, completed the study. No significant differences between mean measured and estimated PAL values were observed (1.37 ± 0.13 versus 1.40 ± 0.34, P = 0.74). Bland Altman analysis illustrated a significant relationship (r = −0.76, P < 0.05) between the two methods; thus the bias was not consistent across a range of physical activity levels, with the more inactive overreporting their physical activity. Conclusion. At an individual level, obese adolescents are unlikely to be able to provide an accurate estimation of their own activity. PMID:25247095

  16. Calculating Measurement Uncertainty of the “Conventional Value of the Result of Weighing in Air”

    DOE PAGES

    Flicker, Celia J.; Tran, Hy D.

    2016-04-02

    The conventional value of the result of weighing in air is frequently used in commercial calibrations of balances. The guidance in OIML D-028 for reporting uncertainty of the conventional value is too terse. When calibrating mass standards at low measurement uncertainties, it is necessary to perform a buoyancy correction before reporting the result. When calculating the conventional result after calibrating true mass, the uncertainty due to calculating the conventional result is correlated with the buoyancy correction. We show through Monte Carlo simulations that the measurement uncertainty of the conventional result is less than the measurement uncertainty when reporting true mass.more » The Monte Carlo simulation tool is available in the online version of this article.« less

  17. Source of parental reports of child height and weight during phone interviews and influence on obesity prevalence estimates among children aged 3-17 years.

    PubMed

    Skinner, Asheley Cockrell; Miles, Donna; Perrin, Eliana M; Coyne-Beasley, Tamera; Ford, Carol

    2013-01-01

    We compared parental reports of children's height and weight when the values were estimated vs. parent-measured to determine how these reports influence the estimated prevalence of childhood obesity. In the 2007 and 2008 North Carolina Child Health Assessment and Monitoring Program surveys, parents reported height and weight for children aged 3-17 years. When parents reported the values were not measured (by doctor, school, or home), they were asked to measure their child and were later called back. We categorized body mass index status using standard CDC definitions, and we used Chi-square tests and the Stuart-Maxwell test of marginal homogeneity to examine reporting differences. About 80% (n=509) of the 638 parents who reported an unmeasured height and/or weight participated in a callback and provided updated measures. Children originally classified as obese were subsequently classified as obese (67%), overweight (13%), and healthy weight (19%). An estimated 28% of younger children (<10 years of age) vs. 6% of older children (aged ≥10 years) were reclassified on callback. Having parents who guessed the height and weight of their children and then reported updated values did not significantly change the overall population estimates of obesity. Our findings demonstrate that using parent-reported height and weight values may be sufficient to provide reasonable estimates of obesity prevalence. Systematically asking the source of height and weight information may help improve how it is applied to research of the prevalence of childhood obesity when gold-standard measurements are not available.

  18. Studying the Cost and Value of Library Services: Final Report. Technical Report APLAB/94-3/1,2,3,4.

    ERIC Educational Resources Information Center

    Kantor, Paul B.; And Others

    This is the final technical report (in three parts) of a 15-month long project to study the costs and value of library functions at five major research libraries. Twenty-one services or service aspects were studied, and numerous measures of the importance or benefit of the service to the users were made. These measures were studied together to lay…

  19. The Stahl Multidimensional Inventory of Values and Attitudes (SMIVA): A Report on the Development of an Instrument to Measure the Effects of One Approach to Values Education.

    ERIC Educational Resources Information Center

    Stahl, Robert J.

    1986-01-01

    Reports the steps taken to develop a satisfactory group measure of the Casteel-Stahl model of cognitive-affect-process education. The resulting 60-item Likert format instrument measures a wide array of instructional outcomes, from empathy, communications, decision making, problem solving and personal consistency to acceptance of self and…

  20. Value Similarities among Fathers, Mothers, and Adolescents and the Role of a Cultural Stereotype: Different Measurement Strategies Reconsidered

    ERIC Educational Resources Information Center

    Roest, Annette M. C.; Dubas, Judith Semon; Gerris, Jan R. M.; Engels, Rutger C. M. E.

    2009-01-01

    In research on value similarity and transmission between parents and adolescents, no consensus exists on the level of value similarity. Reports of high-value similarities coexist with reports of low-value similarities within the family. The present study shows that different conclusions may be explained by the use of different measurement…

  1. THE ON-SITE ON-LINE TOOL FOR SITE ASSESSMENT CALCULATIONS

    EPA Science Inventory

    State and Federal Agency personnel often receive modeling reports with undocumented parameter values. The reports give parameter values, but often no indication if the value was measured, taken from the literature, the result of calibration, or some type of estimate. Recent examp...

  2. Radiology Reports With Hyperlinks Improve Target Lesion Selection and Measurement Concordance in Cancer Trials.

    PubMed

    Machado, Laura B; Apolo, Andrea B; Steinberg, Seth M; Folio, Les R

    2017-02-01

    Radiology reports often lack the measurements of target lesions that are needed for oncology clinical trials. When available, the measurements in the radiology reports often do not match those in the records used to calculate therapeutic response. This study assessed the clinical value of hyperlinked tumor measurements in multimedia-enhanced radiology reports in the PACS and the inclusion of a radiologist assistant in the process of assessing tumor burden. We assessed 489 target lesions in 232 CT examinations of 71 patients with metastatic genitourinary cancer enrolled in two therapeutic trials. We analyzed target lesion selection and measurement concordance between oncology records (used to calculate therapeutic response) and two types of radiology reports in the PACS: multimedia-enhanced radiology reports and text-only reports. For statistical tests, we used the Wilcoxon signed rank, Wilcoxon rank sum test, and Fisher method to combine p values from the paired and unpaired results. The Fisher exact test was used to compare overall measurement concordance. Concordance on target lesion selection was greater for multimedia-enhanced radiology reports (78%) than the text-only reports (52%) (p = 0.0050). There was also improved overall measurement concordance with the multimedia-enhanced radiology reports (68%) compared with the text-only reports (38%) (p < 0.0001). Compared with text-only reports, hyperlinked multimedia-enhanced radiology reports improved concordance of target lesion selection and measurement with the measurements used to calculate therapeutic response.

  3. Estimates of self-reported dietary behavior related to oral health among adolescents according to the type of food

    PubMed Central

    do AMARAL, Regiane Cristina; SCABAR, Luiz Felipe; SLATER, Betzabeth; FRAZÃO, Paulo

    2014-01-01

    Objective To compare estimates of food behavior related to oral health obtained through a self-report measure and 24 hour dietary recalls (R24h). Method We applied three R24h and one self-report measure in 87 adolescents. The estimates for eleven food items were compared at individual and group levels. Results No significant differences in mean values were found for ice cream, vegetables and biscuits without filling. For the remaining items, the values reported by the adolescents were higher than the values estimated by R24h. The percentage of adolescents who reported intake frequency of 1 or more times/ day was higher than the value obtained through R24h for all food items except soft drinks. The highest values of crude agreement between the instruments, individually, were found in the biscuits without filling (75.9%) and ice cream (72.4%). Conclusion The results suggest that adolescents tend to report a degree of exposure to the food items larger than what they actually experience in their daily lives. PMID:25466475

  4. Critical values in hematology of 862 institutions in China.

    PubMed

    Ye, Y Y; Zhao, H J; Fei, Y; Wang, W; He, F L; Zhong, K; Yuan, S; Wang, Z G

    2017-10-01

    A national survey on critical values in hematology of China laboratories was conducted to determine the current practice and assess the quality indicators so as to obtain a quality improvement. Laboratories participating were asked to submit the general information, the practice of critical value reporting, and the status of timeliness of critical value reporting. A total of 862 laboratories submitted the results. The majority of participants have included white blood cell count, blood platelet count, hemoglobin, prothrombin time, and activated partial thromboplastin time in their critical value lists. Many sources are used for establishing a critical value policy, and some of the laboratories consult with clinicians. The unreported critical value rate, late critical value reporting rate, and clinically unacknowledged rate in China are relatively low, and the median of critical value reporting time is 8-9 minutes. There exists a wide variety for critical value reporting in hematology in China. Laboratories should establish a policy of critical value reporting suited for their own situations and consult with clinicians to set critical value lists. Critical values are generally reported in a timely manner in China, but some measures should be taken to further improve the timeliness of critical value reporting. © 2017 John Wiley & Sons Ltd.

  5. Accuracy of self-reported height, weight and waist circumference in a Japanese sample.

    PubMed

    Okamoto, N; Hosono, A; Shibata, K; Tsujimura, S; Oka, K; Fujita, H; Kamiya, M; Kondo, F; Wakabayashi, R; Yamada, T; Suzuki, S

    2017-12-01

    Inconsistent results have been found in prior studies investigating the accuracy of self-reported waist circumference, and no study has investigated the validity of self-reported waist circumference among Japanese individuals. This study used the diagnostic standard of metabolic syndrome to assess the accuracy of individual's self-reported height, weight and waist circumference in a Japanese sample. Study participants included 7,443 Japanese men and women aged 35-79 years. They participated in a cohort study's baseline survey between 2007 and 2011. Participants' height, weight and waist circumference were measured, and their body mass index was calculated. Self-reported values were collected through a questionnaire before the examination. Strong correlations between measured and self-reported values for height, weight and body mass index were detected. The correlation was lowest for waist circumference (men, 0.87; women, 0.73). Men significantly overestimated their waist circumference (mean difference, 0.8 cm), whereas women significantly underestimated theirs (mean difference, 5.1 cm). The sensitivity of self-reported waist circumference using the cut-off value of metabolic syndrome was 0.83 for men and 0.57 for women. Due to systematic and random errors, the accuracy of self-reported waist circumference was low. Therefore, waist circumference should be measured without relying on self-reported values, particularly in the case of women.

  6. Environments Perceived as Obesogenic Have Lower Residential Property Values

    PubMed Central

    Drewnowski, Adam; Aggarwal, Anju; Rehm, Colin D.; Cohen-Cline, Hannah; Hurvitz, Philip M.; Moudon, Anne V.

    2014-01-01

    Background Studies have tried to link multiple aspects of the built environment with physical activity and obesity rates. Purpose To determine the relation between residential property values and multiple perceived (self-reported) measures of the obesogenic environment. Methods The Seattle Obesity Study (SOS) used a telephone survey of a representative, geographically distributed sample of 2,001 King County adults, collected in 2008–2009 and analyzed in 2012–2013. Home addresses were geocoded. Residential property values at the tax parcel level were obtained from the King County tax assessor. Mean residential property values within a 10-minute walk (833-meter buffer) were calculated for each respondent. Data on multiple perceived measures of the obesogenic environment were collected by self-report. Correlations and multivariable linear regression analyses, stratified by residential density, were used to examine the associations among perceived environmental measures, property values, and BMI. Results Perceived measures of the environment such as crime, heavy traffic, and proximity to bars, liquor stores, and fast food were all associated with lower property values. By contrast, living in neighborhoods that were perceived as safe, quiet, clean, and attractive was associated with higher property values. Higher property values were associated, in turn, with lower BMIs. The observed associations between perceived environment measures and BMI were largely attenuated after accounting for residential property values. Conclusions Perceived measures of obesogenic environments are associated with lower property values. Studies in additional locations need to explore to what extent other perceived environment measures can be reflected in residential property values. PMID:25049218

  7. [Comparison of self-reported anthropometric variables and real measurement data].

    PubMed

    Díaz-García, J; González-Zapata, L I; Estrada-Restrepo, A

    2012-06-01

    The objectives of this study were to evaluate self-reporting of weight, height, and waist circumference, and to compare that perception with the real measurements in college students of the MESPYN cohort--Medellin, Salud Pública y Nutrición--from the University of Antioquia (UdeA), Colombia. A cross-sectional study was conducted starting with the first measurement of the MESPYN Cohort 2009-2010. The sample included volunteer students from different academic areas. Self-perception of weight, height, and waist circumference were recorded before the real measurements were performed. Intraclass correlation coefficients (ICC) were calculated for all the variables, and an alpha of 0.05 was used. The concordance between real measurements and self-referred values was evaluated with the Bland and Altman method. 424 volunteer students were included. The average real weight (kg) in males was 67.4 +/- 10.4 and self-reported: 67.0 +/- 11.0; in females the real value was 55.7 +/- 10.1 and self-reported: 55.0 +/- 9.0. The average real height (m) in males was 1.73 +/- 6.1 and self-reported: 1.73 +/- 6.0; in females the real value was 1.60 +/- 5.9 and self-reported: 1.61 +/- 6.0. In males, the average real waist circumference (cm) was 76.6 +/- 8.0 and self-reported: 75.0 +/- 14.0; in females the real value was 69.9 +/- 8.0 and self-reported: 70.0 +/- 9.0. Weight ICC: 0.956, 95% CI (0.95; 0.97), (p < 0.01); height ICC: 0.953, 95%IC (0.91; 0.97), (p < 0.01), and waist circumference ICC: 0.593, 95% IC (0.55; 0.65), (p < 0.01). In conclusion, anthropometric nutritional evaluation of UdeA students can be performed with self-reported data for weight and height, but the evaluation of abdominal obesity requires direct measurement of waist circumference.

  8. Use of Low-Value Pediatric Services Among the Commercially Insured

    PubMed Central

    Schwartz, Aaron L.; Volerman, Anna; Conti, Rena M.; Huang, Elbert S.

    2016-01-01

    BACKGROUND: Claims-based measures of “low-value” pediatric services could facilitate the implementation of interventions to reduce the provision of potentially harmful services to children. However, few such measures have been developed. METHODS: We developed claims-based measures of 20 services that typically do not improve child health according to evidence-based guidelines (eg, cough and cold medicines). Using these measures and claims from 4.4 million commercially insured US children in the 2014 Truven MarketScan Commercial Claims and Encounters database, we calculated the proportion of children who received at least 1 low-value pediatric service during the year, as well as total and out-of-pocket spending on these services. We report estimates based on "narrow" measures designed to only capture instances of service use that were low-value. To assess the sensitivity of results to measure specification, we also reported estimates based on "broad measures" designed to capture most instances of service use that were low-value. RESULTS: According to the narrow measures, 9.6% of children in our sample received at least 1 of the 20 low-value services during the year, resulting in $27.0 million in spending, of which $9.2 million was paid out-of-pocket (33.9%). According to the broad measures, 14.0% of children in our sample received at least 1 of the 20 low-value services during the year. CONCLUSIONS: According to a novel set of claims-based measures, at least 1 in 10 children in our sample received low-value pediatric services during 2014. Estimates of low-value pediatric service use may vary substantially with measure specification. PMID:27940698

  9. Correlation Between Acoustic Measurements and Self-Reported Voice Disorders Among Female Teachers.

    PubMed

    Lin, Feng-Chuan; Chen, Sheng Hwa; Chen, Su-Chiu; Wang, Chi-Te; Kuo, Yu-Ching

    2016-07-01

    Many studies focused on teachers' voice problems and most of them were conducted using questionnaires, whereas little research has investigated the relationship between self-reported voice disorders and objective quantification of voice. This study intends to explore the relationship of acoustic measurements according to self-reported symptoms and its predictive value of future dysphonia. This is a case-control study. Voice samples of 80 female teachers were analyzed, including 40 self-reported voice disorders (VD) and 40 self-reported normal voice (NVD) subjects. The acoustic measurements included jitter, shimmer, and noise-to-harmonics ratio (NHR). Levene's t test and logistic regression were used to analyze the differences between VD and NVD and the relationship between self-reported voice conditions and the acoustic measurements. To examine whether acoustic measurements can be used to predict further voice disorders, we applied a receiver operating characteristic (ROC) curve to determine the cutoff values and the associated sensitivity and specificity. The results showed that jitter, shimmer, and the NHR of VD were significantly higher than those of NVD. Among the parameters, the NHR and shimmer demonstrated the highest correlation with self-reported voice disorders. By using the NHR ≥0.138 and shimmer ≥0.470 dB as the cutoff values, the ROC curve displayed 72.5% of sensitivity and 75% of specificity, and the overall positive predictive value for subsequent dysphonia achieved 60%. This study demonstrated a significant correlation between acoustic measurements and self-reported dysphonic symptoms. NHR and ShdB are two acoustic parameters that are more able to reflect vocal abnormalities and, probably, to predict subsequent subjective voice disorder. Future research recruiting more subjects in other occupations and genders shall validate the preliminary results revealed in this study. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  10. Managing Environmental Liabilities using Full Lifecycle Accounting

    DTIC Science & Technology

    2009-05-01

    aniJtl’lnut, ... Ill ld II d»INi"’ Ill £¢ttl> I .. IN F<£~DIO:L 11Contains Enfos Confidential and Proprietary Information EMERGING “ FAIR VALUE MEASUREMENT... Fair value measurement, also known as “mark-to-market”, has emerged as the favored measurement principle under U.S. and international financial...reporting standards over the past decade. In recent years, the FASB has adopted numerous standards requiring fair value measurement of liabilities

  11. Existence Values for Groundwater (1989)

    EPA Pesticide Factsheets

    This study reports the findings of a preliminary investigation into the existence (nonuse) values people hold for groundwater resources and how these values can be measured for use in benefit/cost analysis.

  12. Setting the equation: establishing value in spine care.

    PubMed

    Resnick, Daniel K; Tosteson, Anna N A; Groman, Rachel F; Ghogawala, Zoher

    2014-10-15

    Topic review. Describe value measurement in spine care and discuss the motivation for, methods for, and limitations of such measurement. Spinal disorders are common and are an important cause of pain and disability. Numerous complementary and competing treatment strategies are used to treat spinal disorders, and the costs of these treatments is substantial and continue to rise despite clear evidence of improved health status as a result of these expenditures. The authors present the economic and legislative imperatives forcing the assessment of value in spine care. The definition of value in health care and methods to measure value specifically in spine care are presented. Limitations to the utility of value judgments and caveats to their use are presented. Examples of value calculations in spine care are presented and critiqued. Methods to improve and broaden the measurement of value across spine care are suggested, and the role of prospective registries in measuring value is discussed. Value can be measured in spine care through the use of appropriate economic measures and patient-reported outcomes measures. Value must be interpreted in light of the perspective of the assessor, the duration of the assessment period, the degree of appropriate risk stratification, and the relative value of treatment alternatives.

  13. Viscosity of saturated R152a measured with a vibrating wire viscometer

    NASA Astrophysics Data System (ADS)

    van der Gulik, P. S.

    1995-07-01

    Earlier reported values of the viscosity coefficient of the refrigerant R152a (1,1-difluoroethane) have been recalculated with an improved value for the mechanical damping of the vibrating wire viscometer. The measurements were taken along the saturation line both in the saturated liquid and in the saturated vapor every 10 K from 243 up to 393 K by means of a vibrating wire viscometer The damping of the vibration of the wire is a measure for the viscosity provided that the mechanical damping is subtracted. The latter is usually measured in vacuum. It turns out that the damping value measured in this way depends on the vacuum pressure and on the way the wire has been handled before. It appeared that the damping applied previously, measured after 6 days of pumping, is too small, resulting in values of the viscosity coefficient which are too large. The effect on the data for the saturated-liquid viscosity is small, but the new saturated-vapor viscosity data agree much better with the unsaturated-vapor data reported by Takahashi et al.

  14. Minnesota anglers' fisheries-related value orientations and their stewardship of fish resources

    USGS Publications Warehouse

    Bruskotter, J.T.; Fulton, D.C.

    2008-01-01

    Research on natural resource-related values and value orientations has grown substantially over the past decade. However, existing studies have focused almost exclusively on value orientations related to wildlife and forests. This article reports data from two mail surveys of Minnesota anglers used to develop scales for measuring fisheries-related value orientations. We report results of regression analyses examining the relationship between anglers' value orientations and norms concerning fisheries stewardship and the use of technological aids to angling. Results indicate 10 items reliably measure three value orientations we termed utilitarianism, dominance, and protectionism. Regression analyses suggest anglers' stewardship norms are influenced by all three value orientation types, while support for the use of technological aids was related with protectionism and utilitarianism, but not dominance. Results suggest anglers' fisheries-related value orientations cannot be adequately captured using single domain scales. Implications for the study of natural resources-related value orientations are discussed. Copyright ?? Taylor & Francis Group, LLC.

  15. The current state of nursing performance measurement, public reporting, and value-based purchasing.

    PubMed

    Kurtzman, Ellen T; Dawson, Ellen M; Johnson, Jean E

    2008-08-01

    Over the last decade, there has been a substantial investment in holding health care providers accountable for the quality of care provided in hospitals and other settings of care. This investment has been realized through the proliferation of national policies that address performance measurement, public reporting, and value-based purchasing. Although nurses represent the largest segment of the health care workforce and despite their acknowledged role in patient safety and health care outcomes, they have been largely absent from policy setting in these areas. This article provides an analysis of current nursing performance measurement and public reporting initiatives and presents a summary of emerging trends in value-based purchasing, with an emphasis on activities in the United States. The article synthesizes issues of relevance to advancing the current climate for nursing quality and concludes with key issues for future policy setting.

  16. Precise Penning trap measurements of double β-decay Q-values

    NASA Astrophysics Data System (ADS)

    Redshaw, M.; Brodeur, M.; Bollen, G.; Bustabad, S.; Eibach, M.; Gulyuz, K.; Izzo, C.; Lincoln, D. L.; Novario, S. J.; Ringle, R.; Sandler, R.; Schwarz, S.; Valverde, A. A.

    2015-10-01

    The double β-decay (ββ -decay) Q-value, defined as the mass difference between parent and daughter atoms, is an important parameter for both two-neutrino ββ -decay (2 νββ) and neutrinoless ββ -decay (0 νββ) experiments. The Q-value enters into the calculation of the phase space factors, which relate the measured ββ -decay half-life to the nuclear matrix element and, in the case of 0 νββ , the effective Majorana mass of the neutrino. In addition, the Q-value defines the total kinetic energy of the two electrons emitted in 0 νββ , corresponding to the location of the single peak that is the sought after signature of 0 νββ . Hence, it is essential to have a precise and accurate Q-value determination. Over the last decade, the Penning trap mass spectrometry community has made a significant effort to provide precise ββ -decay Q-value determinations. Here we report on recent measurements with the Low Energy Beam and Ion Trap (LEBIT) facility at the National Superconducting Cyclotron Laboratory (NSCL) of the 48Ca, 82Se, and 96Zr Q-values. These measurements complete the determination of ββ -decay Q-values for the 11 ``best'' candidates (those with Q >2 MeV). We also report on a measurement of the 78Kr double electron capture (2EC) Q-value and discuss ongoing Penning trap measurements relating to ββ -decay and 2EC. Support from NSF Contract No. PHY-1102511, and DOE Grant No. 03ER-41268.

  17. Direct quantum process tomography via measuring sequential weak values of incompatible observables.

    PubMed

    Kim, Yosep; Kim, Yong-Su; Lee, Sang-Yun; Han, Sang-Wook; Moon, Sung; Kim, Yoon-Ho; Cho, Young-Wook

    2018-01-15

    The weak value concept has enabled fundamental studies of quantum measurement and, recently, found potential applications in quantum and classical metrology. However, most weak value experiments reported to date do not require quantum mechanical descriptions, as they only exploit the classical wave nature of the physical systems. In this work, we demonstrate measurement of the sequential weak value of two incompatible observables by making use of two-photon quantum interference so that the results can only be explained quantum physically. We then demonstrate that the sequential weak value measurement can be used to perform direct quantum process tomography of a qubit channel. Our work not only demonstrates the quantum nature of weak values but also presents potential new applications of weak values in analyzing quantum channels and operations.

  18. Calibration of self-report tools for physical activity research: the Physical Activity Questionnaire (PAQ)

    PubMed Central

    2014-01-01

    Background The utility of self-report measures of physical activity (PA) in youth can be greatly enhanced by calibrating self-report output against objectively measured PA data. This study demonstrates the potential of calibrating self-report output against objectively measured physical activity (PA) in youth by using a commonly used self-report tool called the Physical Activity Questionnaire (PAQ). Methods A total of 148 participants (grades 4 through 12) from 9 schools (during the 2009–2010 school year) wore an Actigraph accelerometer for 7 days and then completed the PAQ. Multiple linear regression modeling was used on 70% of the available sample to develop a calibration equation and this was cross validated on an independent sample of participants (30% of sample). Results A calibration model with age, gender, and PAQ scores explained 40% of the variance in values for the percentage of time in moderate-to-vigorous PA (%MVPA) measured from the accelerometers (%MVPA = 14.56 - (sex*0.98) - (0.84*age) + (1.01*PAQ)). When tested on an independent, hold-out sample, the model estimated %MVPA values that were highly correlated with the recorded accelerometer values (r = .63) and there was no significant difference between the estimated and recorded activity values (mean diff. = 25.3 ± 18.1 min; p = .17). Conclusions These results suggest that the calibrated PAQ may be a valid alternative tool to activity monitoring instruments for estimating %MVPA in groups of youth. PMID:24886625

  19. Calibration of self-report tools for physical activity research: the Physical Activity Questionnaire (PAQ).

    PubMed

    Saint-Maurice, Pedro F; Welk, Gregory J; Beyler, Nicholas K; Bartee, Roderick T; Heelan, Kate A

    2014-05-16

    The utility of self-report measures of physical activity (PA) in youth can be greatly enhanced by calibrating self-report output against objectively measured PA data.This study demonstrates the potential of calibrating self-report output against objectively measured physical activity (PA) in youth by using a commonly used self-report tool called the Physical Activity Questionnaire (PAQ). A total of 148 participants (grades 4 through 12) from 9 schools (during the 2009-2010 school year) wore an Actigraph accelerometer for 7 days and then completed the PAQ. Multiple linear regression modeling was used on 70% of the available sample to develop a calibration equation and this was cross validated on an independent sample of participants (30% of sample). A calibration model with age, gender, and PAQ scores explained 40% of the variance in values for the percentage of time in moderate-to-vigorous PA (%MVPA) measured from the accelerometers (%MVPA = 14.56 - (sex*0.98) - (0.84*age) + (1.01*PAQ)). When tested on an independent, hold-out sample, the model estimated %MVPA values that were highly correlated with the recorded accelerometer values (r = .63) and there was no significant difference between the estimated and recorded activity values (mean diff. = 25.3 ± 18.1 min; p = .17). These results suggest that the calibrated PAQ may be a valid alternative tool to activity monitoring instruments for estimating %MVPA in groups of youth.

  20. Determining the value of disease management programs.

    PubMed

    Selby, Joe V; Scanlon, Dennis; Lafata, Jennifer Elston; Villagra, Victor; Beich, Jeff; Salber, Patricia R

    2003-09-01

    Increasing prevalence, rising costs, and persisting deficiencies in quality of care for chronic diseases pose economic and policy challenges to providers and purchasers. Disease management (DM) programs may address these challenges, but neither purchasers nor providers can assess their value. The potpourri of current quality indicators provides limited insight into the actual clinical benefit achieved. A conference sponsored by the Agency for Healthcare Research and Quality (AHRQ) and held in October 2002 explored new approaches to measuring and reporting the value of DM for diabetes mellitus. Quantifying the value of DM requires measuring clinical benefit and net impact on health care costs for the entire population with diabetes. If quality is measured with indicators that are clearly linked to outcomes, clinical benefit can be estimated. Natural history models combine the expected benefits of improvements in multiple indicators to yield a single, composite measure, the quality-adjusted life-year. Such metrics could fairly express, in terms of survival and complications prevention, relatively disparate DM programs' benefits. Measuring and comparing health care costs requires data validation and appropriate case-mix adjustment. Comparing value across programs may provide more accurate assessments of performance, enhance quality improvement efforts within systems, and contribute generalizable knowledge on the utility of DM approaches. Conference attendees recommended pilot projects to further explore use of natural history models for measuring and reporting the value of DM.

  1. Double Star Measurements Using a Webcam and CCD Camera, Annual Report of 2016

    NASA Astrophysics Data System (ADS)

    Schlimmer, Jeorg

    2018-01-01

    This report shows the results on 223 double star measurements from 2016; mini-mum separation is 1.23 a.s. (STF1024AB), maximum separation is 371 a.s. (STF1424AD). The mean value of all measurements is 18.7 a.s.

  2. Theoretical framework and methodological development of common subjective health outcome measures in osteoarthritis: a critical review

    PubMed Central

    Pollard, Beth; Johnston, Marie; Dixon, Diane

    2007-01-01

    Subjective measures involving clinician ratings or patient self-assessments have become recognised as an important tool for the assessment of health outcome. The value of a health outcome measure is usually assessed by a psychometric evaluation of its reliability, validity and responsiveness. However, psychometric testing involves an accumulation of evidence and has recognised limitations. It has been suggested that an evaluation of how well a measure has been developed would be a useful additional criteria in assessing the value of a measure. This paper explored the theoretical background and methodological development of subjective health status measures commonly used in osteoarthritis research. Fourteen subjective health outcome measures commonly used in osteoarthritis research were examined. Each measure was explored on the basis of their i) theoretical framework (was there a definition of what was being assessed and was it part of a theoretical model?) and ii) methodological development (what was the scaling strategy, how were the items generated and reduced, what was the response format and what was the scoring method?). Only the AIMS, SF-36 and WHOQOL defined what they were assessing (i.e. the construct of interest) and no measure assessed was part of a theoretical model. None of the clinician report measures appeared to have implemented a scaling procedure or described the rationale for the items selected or scoring system. Of the patient self-report measures, the AIMS, MPQ, OXFORD, SF-36, WHOQOL and WOMAC appeared to follow a standard psychometric scaling method. The DRP and EuroQol used alternative scaling methods. The review highlighted the general lack of theoretical framework for both clinician report and patient self-report measures. This review also drew attention to the wide variation in the methodological development of commonly used measures in OA. While, in general the patient self-report measures had good methodological development, the clinician report measures appeared less well developed. It would be of value if new measures defined the construct of interest and, that the construct, be part of theoretical model. By ensuring measures are both theoretically and empirically valid then improvements in subjective health outcome measures should be possible. PMID:17343739

  3. Supporting data for hydrologic studies in San Francisco Bay, California : meteorological measurements at the Port of Redwood City during 1998-2001

    USGS Publications Warehouse

    Schemel, Laurence E.

    2002-01-01

    Meteorological data were collected during 1998-2001 at the Port of Redwood City, California, to support hydrologic studies in South San Francisco Bay. The measured meteorological variables were air temperature, atmospheric pressure, quantum flux (insolation), and four parameters of wind speed and direction: scalar mean horizontal wind speed, (vector) resultant horizontal wind speed, resultant wind direction, and standard deviation of the wind direction. Hourly mean values based on measurements at five-minute intervals were logged at the site. Daily mean values were computed for temperature, infolation, pressure, and scalar wind speed. Daily mean values for 1998-2001 are described in this report, and a short record of hourly mean values is compared to data from another near-by station. Data (hourly and daily mean) from the entire period of record (starting in April 1992) and reports describing data prior to 1998 are provided.

  4. Determining Risk of Falls in Community Dwelling Older Adults: A Systematic Review and Meta-analysis Using Posttest Probability.

    PubMed

    Lusardi, Michelle M; Fritz, Stacy; Middleton, Addie; Allison, Leslie; Wingood, Mariana; Phillips, Emma; Criss, Michelle; Verma, Sangita; Osborne, Jackie; Chui, Kevin K

    Falls and their consequences are significant concerns for older adults, caregivers, and health care providers. Identification of fall risk is crucial for appropriate referral to preventive interventions. Falls are multifactorial; no single measure is an accurate diagnostic tool. There is limited information on which history question, self-report measure, or performance-based measure, or combination of measures, best predicts future falls. First, to evaluate the predictive ability of history questions, self-report measures, and performance-based measures for assessing fall risk of community-dwelling older adults by calculating and comparing posttest probability (PoTP) values for individual test/measures. Second, to evaluate usefulness of cumulative PoTP for measures in combination. To be included, a study must have used fall status as an outcome or classification variable, have a sample size of at least 30 ambulatory community-living older adults (≥65 years), and track falls occurrence for a minimum of 6 months. Studies in acute or long-term care settings, as well as those including participants with significant cognitive or neuromuscular conditions related to increased fall risk, were excluded. Searches of Medline/PubMED and Cumulative Index of Nursing and Allied Health (CINAHL) from January 1990 through September 2013 identified 2294 abstracts concerned with fall risk assessment in community-dwelling older adults. Because the number of prospective studies of fall risk assessment was limited, retrospective studies that classified participants (faller/nonfallers) were also included. Ninety-five full-text articles met inclusion criteria; 59 contained necessary data for calculation of PoTP. The Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS) was used to assess each study's methodological quality. Study design and QUADAS score determined the level of evidence. Data for calculation of sensitivity (Sn), specificity (Sp), likelihood ratios (LR), and PoTP values were available for 21 of 46 measures used as search terms. An additional 73 history questions, self-report measures, and performance-based measures were used in included articles; PoTP values could be calculated for 35. Evidence tables including PoTP values were constructed for 15 history questions, 15 self-report measures, and 26 performance-based measures. Recommendations for clinical practice were based on consensus. Variations in study quality, procedures, and statistical analyses challenged data extraction, interpretation, and synthesis. There was insufficient data for calculation of PoTP values for 63 of 119 tests. No single test/measure demonstrated strong PoTP values. Five history questions, 2 self-report measures, and 5 performance-based measures may have clinical usefulness in assessing risk of falling on the basis of cumulative PoTP. Berg Balance Scale score (≤50 points), Timed Up and Go times (≥12 seconds), and 5 times sit-to-stand times (≥12) seconds are currently the most evidence-supported functional measures to determine individual risk of future falls. Shortfalls identified during review will direct researchers to address knowledge gaps.

  5. Value-Based Reimbursement: Impact of Curtailing Physician Autonomy in Medical Decision Making.

    PubMed

    Gupta, Dipti; Karst, Ingolf; Mendelson, Ellen B

    2016-02-01

    In this article, we define value in the context of reimbursement and explore the effect of shifting reimbursement paradigms on the decision-making autonomy of a women's imaging radiologist. The current metrics used for value-based reimbursement such as report turnaround time are surrogate measures that do not measure value directly. The true measure of a physician's value in medicine is accomplishment of better health outcomes, which, in breast imaging, are best achieved with a physician-patient relationship. Complying with evidence-based medicine, which includes data-driven best clinical practices, a physician's clinical expertise, and the patient's values, will improve our science and preserve the art of medicine.

  6. Partitioning of fluorotelomer alcohols to octanol and different sources of dissolved organic carbon.

    PubMed

    Carmosini, Nadia; Lee, Linda S

    2008-09-01

    Interest in the environmental fate of fluorotelomer alcohols (FTOHs) has spurred efforts to understand their equilibrium partitioning behavior. Experimentally determined partition coefficients for FTOHs between soil/water and air/water have been reported, but direct measurements of partition coefficients for dissolved organic carbon (DOC)/water (K(doc)) and octanol/ water(K(ow)) have been lacking. Here we measured the partitioning of 8:2 and 6:2 FTOH between one or more types of DOC and water using enhanced solubility or dialysis bag techniques, and also quantified K(ow) values for 4:2 to 8:2 FTOH using a batch equilibration method. The range in measured log K(doc) values for 8:2 FTOH using the enhanced solubility technique with DOC derived from two soils, two biosolids, and three reference humic acids is 2.00-3.97 with the lowest values obtained for the biosolids and an average across all other DOC sources (biosolid DOC excluded) of 3.54 +/- 0.29. For 6:2 FTOH and Aldrich humic acid, a log K(doc) value of 1.96 +/- 0.45 was measured using the dialysis technique. These average values are approximately 1 to 2 log units lower than previously indirectly estimated K(doc) values. Overall, the affinity for DOC tends to be slightly lower than that for particulate soil organic carbon. Measured log K(ow) values for 4:2 (3.30 +/- 0.04), 6:2 (4.54 +/- 0.01), and 8:2 FTOH (5.58 +/- 0.06) were in good agreement with previously reported estimates. Using relationships between experimentally measured partition coefficients and C-atom chain length, we estimated K(doc) and K(ow) values for shorter and longer chain FTOHs, respectively, that we were unable to measure experimentally.

  7. Interlaboratory comparison for the measurement of particle size and zeta potential of silica nanoparticles in an aqueous suspension

    NASA Astrophysics Data System (ADS)

    Lamberty, Andrée; Franks, Katrin; Braun, Adelina; Kestens, Vikram; Roebben, Gert; Linsinger, Thomas P. J.

    2011-12-01

    The Institute for Reference Materials and Measurements has organised an interlaboratory comparison (ILC) to allow the participating laboratories to demonstrate their proficiency in particle size and zeta potential measurements on monomodal aqueous suspensions of silica nanoparticles in the 10-100 nm size range. The main goal of this ILC was to identify competent collaborators for the production of certified nanoparticle reference materials. 38 laboratories from four different continents participated in the ILC with different methods for particle sizing and determination of zeta potential. Most of the laboratories submitted particle size results obtained with centrifugal liquid sedimentation (CLS), dynamic light scattering (DLS) or electron microscopy (EM), or zeta potential values obtained via electrophoretic light scattering (ELS). The results of the laboratories were evaluated using method-specific z scores, calculated on the basis of consensus values from the ILC. For CLS (13 results) and EM (13 results), all reported values were within the ±2 | z| interval. For DLS, 25 of the 27 results reported were within the ±2 | z| interval, the two other results were within the ±3 | z| interval. The standard deviations of the corresponding laboratory mean values varied between 3.7 and 6.5%, which demonstrates satisfactory interlaboratory comparability of CLS, DLS and EM particle size values. From the received test reports, a large discrepancy was observed in terms of the laboratory's quality assurance systems, which are equally important for the selection of collaborators in reference material certification projects. Only a minority of the participating laboratories is aware of all the items that are mandatory in test reports compliant to ISO/IEC 17025 (ISO General requirements for the competence of testing and calibration laboratories. International Organisation for Standardization, Geneva, 2005b). The absence of measurement uncertainty values in the reports, for example, hindered the calculation of zeta scores.

  8. Quality of life in asthma patients.

    PubMed

    Ferreira, Lara Noronha; Brito, Ulisses; Ferreira, Pedro Lopes

    2010-01-01

    In this paper we present a study whose main aim is the measurement of the Health Related Quality of Life (HRQoL) of patients with asthma and the presentation of a first draft of normative values as measured by the SF-6D for asthma patients. In addition, we investigate how far non-disease-specific HRQoL measures can distinguish groups in terms of sociodemographic characteristics. The Portuguese versions of the EQ-5D, SF-6D, AQLQ(S) and ACQ were administered using personal interviews to a representative sample of the Portuguese population with asthma. Most of the individuals did not report significant problems in the dimensions used, with the exception of the physical functioning, where individuals reported moderate limitations. The mean utility value was 0.86. Male gender, young, single, individuals with high educational attainment level, employed, individuals with high income and those residing in urban areas reported higher utility levels. As expected, those who were in a severe stadium of the disease reported lower mean utility levels than those who were in a less severe stadium of the disease. Normative values for the SF-6D were computed for patients with asthma by gender, age, marital status, educational attainment level, employment status, area of residence and average monthly net income. The preference-based measures used in this study distinguish patient groups with asthma in terms of socio- demographic groups. The normative values can be used in economic evaluation and clinical studies as they incorporate patients' preferences and translate the value attributed to patients' health state.

  9. Determination of perfluorinated alkyl acid concentrations in biological standard reference materials.

    PubMed

    Reiner, Jessica L; O'Connell, Steven G; Butt, Craig M; Mabury, Scott A; Small, Jeff M; De Silva, Amila O; Muir, Derek C G; Delinsky, Amy D; Strynar, Mark J; Lindstrom, Andrew B; Reagen, William K; Malinsky, Michelle; Schäfer, Sandra; Kwadijk, Christiaan J A F; Schantz, Michele M; Keller, Jennifer M

    2012-11-01

    Standard reference materials (SRMs) are homogeneous, well-characterized materials used to validate measurements and improve the quality of analytical data. The National Institute of Standards and Technology (NIST) has a wide range of SRMs that have mass fraction values assigned for legacy pollutants. These SRMs can also serve as test materials for method development, method validation, and measurement for contaminants of emerging concern. Because inter-laboratory comparison studies have revealed substantial variability of measurements of perfluoroalkyl acids (PFAAs), future analytical measurements will benefit from determination of consensus values for PFAAs in SRMs to provide a means to demonstrate method-specific performance. To that end, NIST, in collaboration with other groups, has been measuring concentrations of PFAAs in a variety of SRMs. Here we report levels of PFAAs and perfluorooctane sulfonamide (PFOSA) determined in four biological SRMs: fish tissue (SRM 1946 Lake Superior Fish Tissue, SRM 1947 Lake Michigan Fish Tissue), bovine liver (SRM 1577c), and mussel tissue (SRM 2974a). We also report concentrations for three in-house quality-control materials: beluga whale liver, pygmy sperm whale liver, and white-sided dolphin liver. Measurements in SRMs show an array of PFAAs, with perfluorooctane sulfonate (PFOS) being the most frequently detected. Reference and information values are reported for PFAAs measured in these biological SRMs.

  10. Electrical Characterization of Polyaniline/polyethylene Oxide Nanofibers for Field Effect Transistors

    NASA Technical Reports Server (NTRS)

    Mueller, Carl H.; Theofylaktos, Noulie; Pinto, Nicholas J.; Robinson, Daryl C.; Miranda, Felix A.

    2002-01-01

    Nanofibers comprised of polyaniline/polyethylene oxide (PANI/PEO) are being developed for novel logic devices. We report the electrical conductivity of PANI/PEO nanofibers with diameters in the 100 to 200 nm range. We measured conductivity values of approx. 0.3 to 1.0 S/cm, which is higher than the values reported for thicker nanofibers, but less than the bulk value of PANI. The electrical measurements were performed by depositing the fibers on pre-electroded, oxidized silicon (Si) substrates. The excellent adherence of the nanofibers to the SiO2 as well as the gold (Au) electrodes may be useful in the design of future devices.

  11. Methods for evaluating stream, riparian, and biotic conditions

    Treesearch

    William S. Platts; Walter F. Megahan; G. Wayne Minshall

    1983-01-01

    This report develops a standard way of measuring stream, riparian, and biotic conditions and evaluates the validity of the measurements recommended. Accuracy and precision of most measurements are defined. This report will be of value to those persons documenting, monitoring, or predicting stream conditions and their biotic resources, especially those related to...

  12. Comparison of self-reported height and weight with controlled height and weight in women and men.

    PubMed

    Schlichting, P; Høilund-Carlsen, P F; Quaade, F

    1981-01-01

    Self-reported height and weight were compared with directly-measured controlled height and weight in 158 women with a median age of 34 years (16-62 years) and in 594 men with a median age of 37 (16-66 years). A model of two one-dimensional linear regressions with two independent variables was used in order to describe the combined influence of both controlled height and controlled weight on self-reported height and on self-reported weight. For both sexes there was a systematic tendency for tall and heavy persons to underestimate their height and weight and conversely for small and thin persons to overestimate these measurements. The influence of controlled weight on self-reported height was statistically significant (women: P less than 0.05; men: P approximately 0.05,) and so was the influence of controlled height on self-reported weight (women: P less than 0.002; men: P less than 0.001). The reported heights and weights of women and men converged towards a pair of desired measures for each sex, ie the values of height and weight for which the reported and the controlled values were identical. For women the desired measures were 159.6 cm and 45.2 kg, for men 176.7 cm and 68.9 kg. The demonstrated differences between self-reported and controlled body measures may invalidate data and conclusions of insurance studies and population surveys based on self-reported measures.

  13. 40 CFR 87.64 - Sampling and analytical procedures for measuring gaseous exhaust emissions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... Round CO2 to the nearest 1 g/kilonewton rO. (c) Report CO2 by calculation from fuel mass flow rate...) [Reserved] (b) Starting January 1, 2011, report CO2 values along with your emission levels of regulated NOX... individual production model was on or after January 1, 2011. By January 1, 2011, report CO2 values along with...

  14. 40 CFR 87.64 - Sampling and analytical procedures for measuring gaseous exhaust emissions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... Round CO2 to the nearest 1 g/kilonewton rO. (c) Report CO2 by calculation from fuel mass flow rate...) [Reserved] (b) Starting January 1, 2011, report CO2 values along with your emission levels of regulated NOX... individual production model was on or after January 1, 2011. By January 1, 2011, report CO2 values along with...

  15. The Role of Patient-Reported Outcome Measures in Value-Based Payment Reform.

    PubMed

    Squitieri, Lee; Bozic, Kevin J; Pusic, Andrea L

    2017-06-01

    The U.S. health care system is currently experiencing profound change. Pressure to improve the quality of patient care and control costs have caused a rapid shift from traditional volume-driven fee-for-service reimbursement to value-based payment models. Under the 2015 Medicare Access and Children's Health Insurance Program Reauthorization Act, providers will be evaluated on the basis of quality and cost efficiency and ultimately receive adjusted reimbursement as per their performance. Although current performance metrics do not incorporate patient-reported outcome measures (PROMs), many wonder whether and how PROMs will eventually fit into value-based payment reform. On November 17, 2016, the second annual Patient-Reported Outcomes in Healthcare Conference brought together international stakeholders across all health care disciplines to discuss the potential role of PROs in value-based health care reform. The purpose of this article was to summarize the findings from this conference in the context of recent literature and guidelines to inform implementation of PROs in value-based payment models. Recommendations for evaluating key perspectives and measurement goals are made to facilitate appropriate use of PROMs to best benefit and amplify the voice of our patients. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  16. Values Education as Good Practice Pedagogy: Evidence from Australian Empirical Research

    ERIC Educational Resources Information Center

    Lovat, Terence

    2017-01-01

    This article focuses on the Australian Government's Values Education Program and, within its context, the "Values Education Good Practice Schools Project" (VEGPSP) Reports and the "Project to Test and Measure the Impact of Values Education on Student Effects and School Ambience," funded federally from 2003 to 2010. Findings…

  17. CrossTalk: The Journal of Defense Software Engineering. Volume 21, Number 4

    DTIC Science & Technology

    2008-04-01

    stability characteristics to those extensively reported for the Cost Performance Index in Earned Value Management . by Kym Henderson and Dr. Ofer...Zwikael Schedule Adherence:A Useful Measure for Project Management This article utilizes the new practice of Earned Schedule to discuss a proposed...measure for further enhancing the practice of Earned Value Management . by Walt Lipke A Review of Boundary Value Analysis Techniques This article reviews

  18. Establishing and Valuing the Effects of Improved Visibility in Eastern United States (1984)

    EPA Pesticide Factsheets

    Report seeks to establish a visibility value function; identify particular activities likely to be influenced by visibility and to measure values to households in producing these activities; and develop estimates of visibility benefits for Eastern US.

  19. Cautionary Note on Reporting Eta-Squared Values from Multifactor ANOVA Designs

    ERIC Educational Resources Information Center

    Pierce, Charles A.; Block, Richard A.; Aguinis, Herman

    2004-01-01

    The authors provide a cautionary note on reporting accurate eta-squared values from multifactor analysis of variance (ANOVA) designs. They reinforce the distinction between classical and partial eta-squared as measures of strength of association. They provide examples from articles published in premier psychology journals in which the authors…

  20. 30 CFR 702.18 - Reporting requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... used or transferred by the operator or related entity and the estimated total fair market value of such... related entity and the estimated total fair market value of such minerals; and (6) The number of tons of... definition of Cumulative measurement period in § 702.5 of this part. (3) The information in the report shall...

  1. Shearwave Dispersion Ultrasonic Vibrometry (SDUV) for measuring prostate shear stiffness and viscosity – An in vitro pilot study

    PubMed Central

    Urban, M.W.; Fatemi, M.; Greenleaf, J.F.

    2011-01-01

    This paper reports shear stiffness and viscosity “virtual biopsy” measurements of three excised non-cancerous human prostates using shearwave dispersion ultrasound vibrometry (SDUV) in vitro. Improved methods for prostate guided-biopsy are required to effectively guide needle biopsy to the suspected site. In addition, tissue stiffness measurement helps identifying a suspected site to perform biopsy because stiffness has been shown to correlate with pathology. More importantly, early detection of prostate cancer may guide minimally-invasive therapy and eliminate insidious procedures. In this work, “virtual” biopsies were taken in multiple locations in three excised prostates. Then, SDUV shear elasticity and viscosity measurements have been performed at the selected “suspicious” locations within the prostates. SDUV measurements of prostate elasticity and viscosity are generally in agreement with preliminary values reported previously in the literature. It is however important to emphasize that the obtained viscoelastic parameters values are local, and not a mean value for the whole prostate. PMID:20595086

  2. Superduck Marine Meteorological Experiment Data Summary: Mean Values and Turbulence Parameters.

    DTIC Science & Technology

    1988-08-01

    number) This report summarizes the Mean values and turbulence parameters Of Meteorological measurements made during an experiment at Duck, NC, during...Sept-Oct 1986. The measure- ments wore made to Calculate wind stress in the nearshore area. Wind stress is a primary forcing function for nearshore waves...measure. Only in recent years has technology made it possible to accurately measure its fluctuations. The krypton hygrometer is a recent development

  3. Physical Activity in Vietnam: Estimates and Measurement Issues.

    PubMed

    Bui, Tan Van; Blizzard, Christopher Leigh; Luong, Khue Ngoc; Truong, Ngoc Le Van; Tran, Bao Quoc; Otahal, Petr; Srikanth, Velandai; Nelson, Mark Raymond; Au, Thuy Bich; Ha, Son Thai; Phung, Hai Ngoc; Tran, Mai Hoang; Callisaya, Michele; Gall, Seana

    2015-01-01

    Our aims were to provide the first national estimates of physical activity (PA) for Vietnam, and to investigate issues affecting their accuracy. Measurements were made using the Global Physical Activity Questionnaire (GPAQ) on a nationally-representative sample of 14706 participants (46.5% males, response 64.1%) aged 25-64 years selected by multi-stage stratified cluster sampling. Approximately 20% of Vietnamese people had no measureable PA during a typical week, but 72.9% (men) and 69.1% (women) met WHO recommendations for PA by adults for their age. On average, 52.0 (men) and 28.0 (women) Metabolic Equivalent Task (MET)-hours/week (largely from work activities) were reported. Work and total PA were higher in rural areas and varied by season. Less than 2% of respondents provided incomplete information, but an additional one-in-six provided unrealistically high values of PA. Those responsible for reporting errors included persons from rural areas and all those with unstable work patterns. Box-Cox transformation (with an appropriate constant added) was the most successful method of reducing the influence of large values, but energy-scaled values were most strongly associated with pathophysiological outcomes. Around seven-in-ten Vietnamese people aged 25-64 years met WHO recommendations for total PA, which was mainly from work activities and higher in rural areas. Nearly all respondents were able to report their activity using the GPAQ, but with some exaggerated values and seasonal variation in reporting. Data transformation provided plausible summary values, but energy-scaling fared best in association analyses.

  4. Methane Emissions from Leak and Loss Audits of Natural Gas Compressor Stations and Storage Facilities.

    PubMed

    Johnson, Derek R; Covington, April N; Clark, Nigel N

    2015-07-07

    As part of the Environmental Defense Fund's Barnett Coordinated Campaign, researchers completed leak and loss audits for methane emissions at three natural gas compressor stations and two natural gas storage facilities. Researchers employed microdilution high-volume sampling systems in conjunction with in situ methane analyzers, bag samples, and Fourier transform infrared analyzers for emissions rate quantification. All sites had a combined total methane emissions rate of 94.2 kg/h, yet only 12% of the emissions total resulted from leaks. Methane slip from exhausts represented 44% of the total emissions. Remaining methane emissions were attributed to losses from pneumatic actuators and controls, engine crankcases, compressor packing vents, wet seal vents, and slop tanks. Measured values were compared with those reported in literature. Exhaust methane emissions were lower than emissions factor estimates for engine exhausts, but when combined with crankcase emissions, measured values were 11.4% lower than predicted by AP-42 as applicable to emissions factors for four-stroke, lean-burn engines. Average measured wet seal emissions were 3.5 times higher than GRI values but 14 times lower than those reported by Allen et al. Reciprocating compressor packing vent emissions were 39 times higher than values reported by GRI, but about half of values reported by Allen et al. Though the data set was small, researchers have suggested a method to estimate site-wide emissions factors for those powered by four-stroke, lean-burn engines based on fuel consumption and site throughput.

  5. Developing an Integrated Information System for the Food Sector. Agricultural Economic Report No. 575.

    ERIC Educational Resources Information Center

    Manchester, Alden

    This document proposes an information system for the food sector that integrates measures of prices, quantities, and values. It suggests that such an integrated information system provides more information about many developments in the food sector than a system that separately measures prices, quantities, or values. Concepts and approaches…

  6. The Learning Outcomes Race: The Value of Self-Reported Gains in Large Research Universities

    ERIC Educational Resources Information Center

    Douglass, John Aubrey; Thomson, Gregg; Zhao, Chun-Mei

    2012-01-01

    Throughout the world, measuring "learning outcomes" is viewed by many stakeholders as a relatively new method to judge the "value added" of colleges and universities. The potential to accurately measure learning gains is also a diagnostic tool for institutional self-improvement. This essay discussed the marketisation of…

  7. Determining Risk of Falls in Community Dwelling Older Adults: A Systematic Review and Meta-analysis Using Posttest Probability

    PubMed Central

    Fritz, Stacy; Middleton, Addie; Allison, Leslie; Wingood, Mariana; Phillips, Emma; Criss, Michelle; Verma, Sangita; Osborne, Jackie; Chui, Kevin K.

    2017-01-01

    Background: Falls and their consequences are significant concerns for older adults, caregivers, and health care providers. Identification of fall risk is crucial for appropriate referral to preventive interventions. Falls are multifactorial; no single measure is an accurate diagnostic tool. There is limited information on which history question, self-report measure, or performance-based measure, or combination of measures, best predicts future falls. Purpose: First, to evaluate the predictive ability of history questions, self-report measures, and performance-based measures for assessing fall risk of community-dwelling older adults by calculating and comparing posttest probability (PoTP) values for individual test/measures. Second, to evaluate usefulness of cumulative PoTP for measures in combination. Data Sources: To be included, a study must have used fall status as an outcome or classification variable, have a sample size of at least 30 ambulatory community-living older adults (≥65 years), and track falls occurrence for a minimum of 6 months. Studies in acute or long-term care settings, as well as those including participants with significant cognitive or neuromuscular conditions related to increased fall risk, were excluded. Searches of Medline/PubMED and Cumulative Index of Nursing and Allied Health (CINAHL) from January 1990 through September 2013 identified 2294 abstracts concerned with fall risk assessment in community-dwelling older adults. Study Selection: Because the number of prospective studies of fall risk assessment was limited, retrospective studies that classified participants (faller/nonfallers) were also included. Ninety-five full-text articles met inclusion criteria; 59 contained necessary data for calculation of PoTP. The Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS) was used to assess each study's methodological quality. Data Extraction: Study design and QUADAS score determined the level of evidence. Data for calculation of sensitivity (Sn), specificity (Sp), likelihood ratios (LR), and PoTP values were available for 21 of 46 measures used as search terms. An additional 73 history questions, self-report measures, and performance-based measures were used in included articles; PoTP values could be calculated for 35. Data Synthesis: Evidence tables including PoTP values were constructed for 15 history questions, 15 self-report measures, and 26 performance-based measures. Recommendations for clinical practice were based on consensus. Limitations: Variations in study quality, procedures, and statistical analyses challenged data extraction, interpretation, and synthesis. There was insufficient data for calculation of PoTP values for 63 of 119 tests. Conclusions: No single test/measure demonstrated strong PoTP values. Five history questions, 2 self-report measures, and 5 performance-based measures may have clinical usefulness in assessing risk of falling on the basis of cumulative PoTP. Berg Balance Scale score (≤50 points), Timed Up and Go times (≥12 seconds), and 5 times sit-to-stand times (≥12) seconds are currently the most evidence-supported functional measures to determine individual risk of future falls. Shortfalls identified during review will direct researchers to address knowledge gaps. PMID:27537070

  8. Performance-based measures and behavioral ratings of executive function in diagnosing attention-deficit/hyperactivity disorder in children.

    PubMed

    Tan, Alexander; Delgaty, Lauren; Steward, Kayla; Bunner, Melissa

    2018-04-16

    Deficits in real-world executive functioning (EF) are a frequent characteristic of attention-deficit/hyperactivity disorder (ADHD). However, the predictive value of using performance-based and behavioral rating measures of EF when diagnosing ADHD remains unclear. The current study investigates the use of performance-based EF measures and a parent-report questionnaire with established ecological validity and clinical utility when diagnosing ADHD. Participants included 21 healthy controls, 21 ADHD-primary inattentive, and 21 ADHD-combined type subjects aged 6-15 years. A brief neuropsychological battery was administered to each subject including common EF assessment measures. Significant differences were not found between groups on most performance-based EF measures, whereas significant differences (p < 0.05) were found on most parent-report behavioral rating scales. Furthermore, performance-based measures did not predict group membership above chance levels. Results further support differences in predictive value of EF performance-based measures compared to parent-report questionnaires when diagnosing ADHD. Further research must investigate the relationship between performance-based and behavioral rating measures when assessing EF in ADHD.

  9. ICP-MS measurement of diffusion coefficients of Cs in NBG-18 graphite

    NASA Astrophysics Data System (ADS)

    Carter, L. M.; Brockman, J. D.; Robertson, J. D.; Loyalka, S. K.

    2015-11-01

    Graphite is used in the HGTR/VHTR as moderator and it also functions as a barrier to fission product release. Therefore, an elucidation of transport of fission products in reactor-grade graphite is required. We have measured diffusion coefficients of Cs in graphite NBG-18 using the release method, wherein we infused spheres of NBG-18 with Cs and measured the release rates in the temperature range of 1090-1395 K. We have obtained: These seem to be the first reported values of Cs diffusion coefficients in NBG-18. The values are lower than those reported for other graphites in the literature.

  10. Thermal Diffusivity in Bone and Hydroxyapatite

    NASA Astrophysics Data System (ADS)

    Calderón, A.; Peña Rodríguez, G.; Muñoz Hernández, R. A.; Díaz Gongora, J. A. I.; Mejia Barradas, C. M.

    2004-09-01

    We report thermal diffusivity measurements in bull bone and commercial hydroxyapatite (HA), both in powder form, in order to determinate the thermal compatibility between these materials. Besides this, we report a comparison between these measured values and those of metallic samples frequently used in implants, as high purity titanium and stainless steel. Our results show a good thermal compatibility (74%) between HA and bone, both in powder form. Finally, it was obtained a one order of magnitude difference between the thermal diffusivity values of metallic samples and those corresponding values to bone and HA being this difference greater in titanium than in stainless steel, which is important to consider in some biomedical and dental applications.

  11. Supplementary comparisons of COOMET in the field of measurements of liquids kinematical viscosity COOMET.M.V-S1

    NASA Astrophysics Data System (ADS)

    Demyanov, A. A.; Tsurko, A. A.

    2017-01-01

    In the comparisons three Newtonian liquid samples were used with nominal values of 20 mm2/s 100 mm2/s and 1000 mm2/s ('20', '100' and '1000' respectively) at 20 °C. Each NMI presented results of measurements values kinematic viscosity samples, uncertainty and uncertainty budget. The purpose of these comparisons was confirmation of measurement and calibration capabilities (CMC) of the relevant NMI. As a reference the values of kinematic viscosity reference samples were taken as average values of measurement results obtained in the research laboratory of the national standards and research in the field of measurements of viscosity and density of the D I Mendeleev Institute for Metrology (VNIIM, RF), as a participant in international comparisons CCM.V-K1, BIPM. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  12. Supplementary comparisons of COOMET in the field of measurements of liquids kinematical viscosity COOMET.M.V-S2

    NASA Astrophysics Data System (ADS)

    Demyanov, A. A.; Tsurko, A. A.

    2017-01-01

    In the comparisons three Newtonian liquid samples were used with nominal values of 20 mm2/s 100 mm2/s and 1000 mm2/s ('20', '100' and '1000', respectively) at 20 °C. Each NMI presented results of measurements values kinematic viscosity samples, uncertainty and uncertainty budget. The purpose of these comparisons was confirmation of measurement and calibration capabilities (CMC) of the relevant NMI. As a reference the values of kinematic viscosity reference samples were taken as average values of measurement results obtained in the research laboratory of the national standards and research in the field of measurements of viscosity and density of the D I Mendeleev Institute for Metrology (VNIIM, RF), as a participant in international comparisons CCM.V-K1, BIPM. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Apparent diffusion coefficient measurements in the differentiation between benign and malignant lesions: a systematic review.

    PubMed

    Vermoolen, M A; Kwee, T C; Nievelstein, R A J

    2012-08-01

    To systematically review the value of apparent diffusion coefficient (ADC) measurement in the differentiation between benign and malignant lesions. A systematic search of the Medline/Pubmed and Embase databases revealed 109 relevant studies. Quality of these articles was assessed using the Quality Assessment of the Studies of Diagnostic Accuracy Included in Systematic Reviews (QUADAS) criteria. Reported ADC values of benign and malignant lesions were compared per organ. The mean quality score of the reviewed articles was 50%. Comparison of ADC values showed marked variation among studies and between benign and malignant lesions in various organs. In several organs, such as breast, liver, and uterus, ADC values discriminated well between benign and malignant lesions. In other organs, such as the salivary glands, thyroid, and pancreas, ADCs were not significantly different between benign and malignant lesions. The potential utility of ADC measurement for the characterisation of tumours differs per organ. Future well-designed studies are required before ADC measurements can be recommended for the differentiation of benign and malignant lesions. These future studies should use standardised acquisition protocols and provide complete reporting of study methods, to facilitate comparison of results and clinical implementation of ADC measurement for tumour characterisation.

  14. Calibration of Smartphone-Based Weather Measurements Using Pairwise Gossip.

    PubMed

    Zamora, Jane Louie Fresco; Kashihara, Shigeru; Yamaguchi, Suguru

    2015-01-01

    Accurate and reliable daily global weather reports are necessary for weather forecasting and climate analysis. However, the availability of these reports continues to decline due to the lack of economic support and policies in maintaining ground weather measurement systems from where these reports are obtained. Thus, to mitigate data scarcity, it is required to utilize weather information from existing sensors and built-in smartphone sensors. However, as smartphone usage often varies according to human activity, it is difficult to obtain accurate measurement data. In this paper, we present a heuristic-based pairwise gossip algorithm that will calibrate smartphone-based pressure sensors with respect to fixed weather stations as our referential ground truth. Based on actual measurements, we have verified that smartphone-based readings are unstable when observed during movement. Using our calibration algorithm on actual smartphone-based pressure readings, the updated values were significantly closer to the ground truth values.

  15. Calibration of Smartphone-Based Weather Measurements Using Pairwise Gossip

    PubMed Central

    Yamaguchi, Suguru

    2015-01-01

    Accurate and reliable daily global weather reports are necessary for weather forecasting and climate analysis. However, the availability of these reports continues to decline due to the lack of economic support and policies in maintaining ground weather measurement systems from where these reports are obtained. Thus, to mitigate data scarcity, it is required to utilize weather information from existing sensors and built-in smartphone sensors. However, as smartphone usage often varies according to human activity, it is difficult to obtain accurate measurement data. In this paper, we present a heuristic-based pairwise gossip algorithm that will calibrate smartphone-based pressure sensors with respect to fixed weather stations as our referential ground truth. Based on actual measurements, we have verified that smartphone-based readings are unstable when observed during movement. Using our calibration algorithm on actual smartphone-based pressure readings, the updated values were significantly closer to the ground truth values. PMID:26421312

  16. Experimental thermal conductivity, thermal diffusivity, and specific heat values for mixtures of nitrogen, oxygen, and argon

    NASA Technical Reports Server (NTRS)

    Perkins, R. A.; Cieszkiewicz, M. T.

    1991-01-01

    Experimental measurements of thermal conductivity and thermal diffusivity obtained with a transient hot-wire apparatus are reported for three mixtures of nitrogen, oxygen, and argon. Values of the specific heat, Cp, are calculated from these measured values and the density calculated with an equation of state. The measurements were made at temperatures between 65 and 303 K with pressures between 0.1 and 70 MPa. The data cover the vapor, liquid, and supercritical gas phases for the three mixtures. The total reported points are 1066 for the air mixture (78.11 percent nitrogen, 20.97 percent oxygen, and 0.92 percent argon), 1058 for the 50 percent nitrogen, 50 percent oxygen mixture, and 864 for the 25 percent nitrogen, 75 oxygen mixture. Empirical thermal conductivity correlations are provided for the three mixtures.

  17. Assessing quality of life in a clinical study on heart rehabilitation patients: how well do value sets based on given or experienced health states reflect patients' valuations?

    PubMed

    Leidl, Reiner; Schweikert, Bernd; Hahmann, Harry; Steinacker, Juergen M; Reitmeir, Peter

    2016-03-22

    Quality of life as an endpoint in a clinical study may be sensitive to the value set used to derive a single score. Focusing on patients' actual valuations in a clinical study, we compare different value sets for the EQ-5D-3L and assess how well they reproduce patients' reported results. A clinical study comparing inpatient (n = 98) and outpatient (n = 47) rehabilitation of patients after an acute coronary event is re-analyzed. Value sets include: 1. Given health states and time-trade-off valuation (GHS-TTO) rendering economic utilities; 2. Experienced health states and valuation by visual analog scale (EHS-VAS). Valuations are compared with patient-reported VAS rating. Accuracy is assessed by mean absolute error (MAE) and by Pearson's correlation ρ. External validity is tested by correlation with established MacNew global scores. Drivers of differences between value sets and VAS are analyzed using repeated measures regression. EHS-VAS had smaller MAEs and higher ρ in all patients and in the inpatient group, and correlated best with MacNew global score. Quality-adjusted survival was more accurately reflected by EHS-VAS. Younger, better educated patients reported lower VAS at admission than the EHS-based value set. EHS-based estimates were mostly able to reproduce patient-reported valuation. Economic utility measurement is conceptually different, produced results less strongly related to patients' reports, and resulted in about 20 % longer quality-adjusted survival. Decision makers should take into account the impact of choosing value sets on effectiveness results. For transferring the results of heart rehabilitation patients from another country or from another valuation method, the EHS-based value set offers a promising estimation option for those decision makers who prioritize patient-reported valuation. Yet, EHS-based estimates may not fully reflect patient-reported VAS in all situations.

  18. Internal friction Q factor measurements in lunar rocks

    NASA Technical Reports Server (NTRS)

    Tittmann, B. R.

    1978-01-01

    In order to better interpret recently reported values for the variation of seismic Q as a function of depth below the lunar surface, we have developed apparatus and made laboratory measurements of Q as a function of hydrostatic pressure, temperature and frequency. Our measurements of the Q associated with shear deformations have demonstrated that the large difference in Q between well outgassed and volatile rich rocks persists to pressures corresponding to a depth of at least 50 km. Here we report new measurements of Q as a function of temperature, on the development of techniques to measure the Q associated with extensional deformations under hydrostatic pressure, on the derivation of theoretical relations between our laboratory Q values and the attenuation coefficient of seismic waves, and on the development of a model for mechanism of adsorption.

  19. Impact of sleep quality on amygdala reactivity, negative affect, and perceived stress.

    PubMed

    Prather, Aric A; Bogdan, Ryan; Hariri, Ahmad R

    2013-05-01

    Research demonstrates a negative impact of sleep disturbance on mood and affect; however, the biological mechanisms mediating these links are poorly understood. Amygdala reactivity to negative stimuli has emerged as one potential pathway. Here, we investigate the influence of self-reported sleep quality on associations between threat-related amygdala reactivity and measures of negative affect and perceived stress. Analyses on data from 299 participants (125 men, 50.5% white, mean [standard deviation] age = 19.6 [1.3] years) who completed the Duke Neurogenetics Study were conducted. Participants completed several self-report measures of negative affect and perceived stress. Threat-related (i.e., angry and fearful facial expressions) amygdala reactivity was assayed using blood oxygen level-dependent functional magnetic resonance imaging. Global sleep quality was assessed using the Pittsburgh Sleep Quality Index. Amygdala reactivity to fearful facial expressions predicted greater depressive symptoms and higher perceived stress in poor (β values = 0.18-1.86, p values < .05) but not good sleepers (β values = -0.13 to -0.01, p values > .05). In sex-specific analyses, men reporting poorer global sleep quality showed a significant association between amygdala reactivity and levels of depression and perceived stress (β values = 0.29-0.44, p values < .05). In contrast, no significant associations were observed in men reporting good global sleep quality or in women, irrespective of sleep quality. This study provides novel evidence that self-reported sleep quality moderates the relationships between amygdala reactivity, negative affect, and perceived stress, particularly among men.

  20. An Algorithm for the Calculation of Exact Term Discrimination Values.

    ERIC Educational Resources Information Center

    Willett, Peter

    1985-01-01

    Reports algorithm for calculation of term discrimination values that is sufficiently fast in operation to permit use of exact values. Evidence is presented to show that relationship between term discrimination and term frequency is crucially dependent upon type of inter-document similarity measure used for calculation of discrimination values. (13…

  1. Chemical composition measurements of the low activity waste (LAW) EPA-Series glasses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fox, K.; Edwards, T. B.

    2016-03-01

    In this report, the Savannah River National Laboratory provides chemical analysis results for a series of simulated low activity waste glasses provided by Pacific Northwest National Laboratory as part of an ongoing development task. The measured chemical composition data are reported and compared with the targeted values for each component for each glass. A detailed review showed no indications of errors in the preparation or measurement of the study glasses. All of the measured sums of oxides for the study glasses fell within the interval of 100.2 to 100.8 wt %, indicating recovery of all components. Comparisons of the targetedmore » and measured chemical compositions showed that the measured values for the glasses met the targeted concentrations within 10% for those components present at more than 5 wt %.« less

  2. The Development of a Mathematics Self-Report Inventory for Turkish Elementary Students

    ERIC Educational Resources Information Center

    Akin, Ayça; Güzeller, Cem Oktay; Evcan, Sinem Sezer

    2016-01-01

    The purpose of the current study is to develop a mathematics self-report inventory (MSRI) to measure Turkish elementary students' mathematics expectancy beliefs and task values based on the expectancy-value theory of achievement motivation. In Study-1 (n = 1,315), exploratory factor analysis (EFA) and reliability analysis are used to evaluate the…

  3. Report on the Evaluation Workshop in the Affective Domain, July, 1970.

    ERIC Educational Resources Information Center

    Lieberman, Marcus; And Others

    A report on the evaluation Workshop to define school objectives is presented. The three-week workshop in defining and measuring objectives in the areas of interests, attitudes and values was held at Emerson School in Elmhurst, Illinois. Some questions studied by the workshop group include the following: Can interests, attitudes, and values be…

  4. The Value-Added Achievement Gains of NBPTS-Certified Teachers in Tennessee: A Brief Report.

    ERIC Educational Resources Information Center

    Stone, J. E.

    This study investigated whether National Board for Professional Teaching Standards (NBPTS)-certified teachers in Tennessee were exceptionally effective in bringing about objectively measured student achievement gains. Tennessee has over 40 NBPTS-certified teachers, 16 of whom teach in grades 3-8 and have value-added teacher reports in the state…

  5. Approaches to Aggregation and Decision Making-A Health Economics Approach: An ISPOR Special Task Force Report [5].

    PubMed

    Phelps, Charles E; Lakdawalla, Darius N; Basu, Anirban; Drummond, Michael F; Towse, Adrian; Danzon, Patricia M

    2018-02-01

    The fifth section of our Special Task Force report identifies and discusses two aggregation issues: 1) aggregation of cost and benefit information across individuals to a population level for benefit plan decision making and 2) combining multiple elements of value into a single value metric for individuals. First, we argue that additional elements could be included in measures of value, but such elements have not generally been included in measures of quality-adjusted life-years. For example, we describe a recently developed extended cost-effectiveness analysis (ECEA) that provides a good example of how to use a broader concept of utility. ECEA adds two features-measures of financial risk protection and income distributional consequences. We then discuss a further option for expanding this approach-augmented CEA, which can introduce many value measures. Neither of these approaches, however, provide a comprehensive measure of value. To resolve this issue, we review a technique called multicriteria decision analysis that can provide a comprehensive measure of value. We then discuss budget-setting and prioritization using multicriteria decision analysis, issues not yet fully resolved. Next, we discuss deliberative processes, which represent another important approach for population- or plan-level decisions used by many health technology assessment bodies. These use quantitative information on CEA and other elements, but the group decisions are reached by a deliberative voting process. Finally, we briefly discuss the use of stated preference methods for developing "hedonic" value frameworks, and conclude with some recommendations in this area. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  6. Measures of Student Non-Cognitive Skills and Political Tolerance after Two Years of the Louisiana Scholarship Program. Louisiana Scholarship Program Evaluation Report #2. Technical Report

    ERIC Educational Resources Information Center

    Mills, Jonathan N.; Cheng, Albert; Hitt, Collin E.; Wolf, Patrick J.; Greene, Jay P.

    2016-01-01

    This report examines the short-term effects of the Louisiana Scholarship Program (LSP) on students' non-cognitive skills and civic values. While a growing number of studies have evaluated K-12 school voucher programs along academic dimensions, few have focused on the development of non-cognitive skills and civic values. This study aims to address…

  7. Changes in total body water during spaceflight

    NASA Technical Reports Server (NTRS)

    Leach, Carolyn S.; Inners, L. D.; Charles, John B.

    1991-01-01

    Total body water (TBW) changes occurring in humans as a consequence of prolonged exposure to microgravity were measured in five male crewmembers of Space Shuttle missions STS-61C and STS-26. It was found that the inflight mean TBW values were significantly different from the preflight and postflight values, while the preflight TBW values were not significantly different from the postflight values. It was also found that individuals may differ in the rate at which they respond to weightlessness. Of the three crewmen who reported experiencing no symptoms of space motion sickness (SMS), two had not exhibited a decrease of TBW at the time of measurements (24 hrs after launch), while the two crewmen who reported SMS of intermediate severity showed a decrease of several kg by 24 hrs, suggesting that dehydration might be an important factor affecting the rate of TBW decrease.

  8. Reliability of the rapid bedside whole-blood quantitative cardiac troponin T assay in the diagnosis of myocardial injury in patients with acute coronary syndrome.

    PubMed

    Saadeddin, Salam; Habbab, Mohammed; Siddieg, Hisham; Fayomi, Mahmoud; Dafterdar, Rofaida

    2004-03-01

    A rapid bedside whole-blood quantitative cTnT assay has recently been developed. We evaluated the reliability of this test for the diagnosis of myocardial injury in patients with acute coronary syndrome (ACS). Whole-blood cTnT levels were measured in 96 patients with ACS using the Roche Cardiac Reader(R) rapid bedside assay device, and the results were compared with serum cTnT levels in the same patients measured by the Roche Elecsys(R) Immunoanalyzer. There were 50 patients with clinical evidence of myocardial injury and 56 without. From the qualitative point of view (reporting negative or positive tests), the results of the rapid bedside tests were identical to those obtained by the serum immunoanalyzer. From quantitative the point of view, the rapid bedside tests could not measure exact values below 0.1 ng/ml (reported negative) or above 2.0 ng/ml (reported >2.0). The measurements made by the rapid bedside tests within the range of 0.1 to 2.0 ng/ml correlated well with those of the serum immunoanalyzer (Cardiac Reader(R) cTnT=0.61, Elecsys(R) cTnT+0.12; r=0.88), but their mean values were significantly lower (1.20I0.71 vs. 1.41I1.03, p=0.0007). The rapid bedside cTnT assay correlates well with immunoanalyzer measurements between the values of 0.1 and 2.0 ng/ml. However, they tend to give significantly lower values and fail to give exact values below 0.1 and above 2.0 ng/ml, which may affect their performance in monitoring and managing patients with ACS, and limit their use in predicting outcome.

  9. SU-F-I-27: Measurement of SAR and Temperature Elevation During MRI Scans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seo, Y

    Purpose: The poor reliability and repeatability of the manufacturer-reported SAR values on clinical MRI systems have been acknowledged. The purpose of this study is to not only measure SAR values, but also RF-induced temperature elevation at 1.5 and 3T MRI systems. Methods: SAR measurement experiment was performed at 1.5 and 3T. Three MRI RF sequences (T1w TSE, T1w inversion recovery, and T2w TSE) with imaging parameters were selected. A hydroxyl-ethylcelluose (HEC) gelled saline phantom mimicking human body tissue was made. Human torso phantom were constructed, based on Korean adult standard anthropometric reference data (Fig.1). FDTD method was utilized to calculatemore » the SAR distribution using Sim4Life software. Based on the results of the simulation, 4 electrical field (E-field) sensors were located inside the phantom. 55 Fiber Bragg Grating (FBG) temperature sensors (27 sensors in upper and lower cover lids, and one sensor located in the center as a reference) were located inside the phantom to measure temperature change during MRI scan (Fig.2). Results: Simulation shows that SAR value is 0.4 W/kg in the periphery and 0.001 W/kg in the center (Fig.2). One 1.5T and one of two 3T MRI systems represent that the measured SAR values were lower than MRI scanner-reported SAR values. However, the other 3T MRI scanner shows that the averaged SAR values measured by probe 2, 3, and 4 are 6.83, 7.59, and 6.01 W/kg, compared to MRI scanner-reported whole body SAR value (<1.5 W/kg) for T2w TSE (Table 1). The temperature elevation measured by FBG sensors is 5.2°C in the lateral shoulder, 5.1°C in the underarm, 4.7°C in the anterior axilla, 4.8°C in the posterior axilla, and 4.8°C in the lateral waist for T2w TSE (Fig.3). Conclusion: It is essential to assess the safety of MRI system for patient by measuring accurate SAR deposited in the body during clinical MRI.« less

  10. Reporting numeric values of complete crowns. Part 1: Clinical preparation parameters.

    PubMed

    Tiu, Janine; Al-Amleh, Basil; Waddell, J Neil; Duncan, Warwick J

    2015-07-01

    An implemented objective measuring system for measuring clinical tooth preparations does not exist. The purpose of this study was to compare clinically achieved tooth preparations for ceramic crowns by general dentists with the recommended values in the literature with an objective measuring method. Two hundred thirty-six stone dies prepared for anterior and posterior complete ceramic crown restorations (IPS e.max Press; Ivoclar Vivadent) were collected from dental laboratories. The dies were scanned and analyzed using the coordinate geometry method. Cross-sectioned images were captured, and the average total occlusal convergence angle, margin width, and abutment height for each preparation was measured and presented with associated 95% confidence intervals. The average total occlusal convergence angles for each tooth type was above the recommended values reported in the literature. The average margin widths (0.40 to 0.83 mm) were below the minimum recommended values (1 to 1.5 mm). The tallest preparations were maxillary canines (5.25 mm), while the shortest preparations were mandibular molars (1.87 mm). Complete crown preparations produced in general practice do not achieve the recommended values found in the literature. However, these recommended values are not based on clinical trials, and the effects of observed shortfalls on the clinical longevity of these restorations are not predictable. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  11. Dark chocolate and blood pressure: a novel study from Jordan.

    PubMed

    Al-Safi, Saafan A; Ayoub, Nehad M; Al-Doghim, Imad; Aboul-Enein, Faisal H

    2011-11-01

    The goal of this study was to assess the effect of dark chocolate intake on cardiovascular parameters like blood pressure and heart rate values in a normotensive population. This is a randomized cross-sectional study involving a total of 14,310 adults that were selected from various regions of Jordan. Well-trained pharmacy students interviewed participants in the outpatient settings. Participants reported their weekly intake of dark chocolate that has been further classified into mild (1-2 bars/week), moderate (3-4 bars/week), and high intake ( > 4 bars/week). For each participant, the systolic blood pressure (SBP), diastolic blood pressure (DBP), and heart rate were measured three times with (10-15) minute intervals in the sitting position and the resting state. The arterial blood pressure (ABP) was calculated from the measured SBP and DBP values. All measured blood pressure values were significantly decreased for participants who reported higher dark chocolate consumption. Our results showed that heart rate values were not affected by variable intake of dark chocolate. In addition, increasing dark chocolate intake was associated with a significant decrease of blood pressure values in participants irrespective of the family history of hypertension or the age of the individual. However, heart rate values were unaffected. Higher intake of dark chocolate can be associated with lower values of blood pressure, while its effect on heart rate values was not consistent.

  12. Physical Activity in Vietnam: Estimates and Measurement Issues

    PubMed Central

    Bui, Tan Van; Blizzard, Christopher Leigh; Luong, Khue Ngoc; Truong, Ngoc Le Van; Tran, Bao Quoc; Otahal, Petr; Srikanth, Velandai; Nelson, Mark Raymond; Au, Thuy Bich; Ha, Son Thai; Phung, Hai Ngoc; Tran, Mai Hoang; Callisaya, Michele; Gall, Seana

    2015-01-01

    Introduction Our aims were to provide the first national estimates of physical activity (PA) for Vietnam, and to investigate issues affecting their accuracy. Methods Measurements were made using the Global Physical Activity Questionnaire (GPAQ) on a nationally-representative sample of 14706 participants (46.5% males, response 64.1%) aged 25−64 years selected by multi-stage stratified cluster sampling. Results Approximately 20% of Vietnamese people had no measureable PA during a typical week, but 72.9% (men) and 69.1% (women) met WHO recommendations for PA by adults for their age. On average, 52.0 (men) and 28.0 (women) Metabolic Equivalent Task (MET)-hours/week (largely from work activities) were reported. Work and total PA were higher in rural areas and varied by season. Less than 2% of respondents provided incomplete information, but an additional one-in-six provided unrealistically high values of PA. Those responsible for reporting errors included persons from rural areas and all those with unstable work patterns. Box-Cox transformation (with an appropriate constant added) was the most successful method of reducing the influence of large values, but energy-scaled values were most strongly associated with pathophysiological outcomes. Conclusions Around seven-in-ten Vietnamese people aged 25–64 years met WHO recommendations for total PA, which was mainly from work activities and higher in rural areas. Nearly all respondents were able to report their activity using the GPAQ, but with some exaggerated values and seasonal variation in reporting. Data transformation provided plausible summary values, but energy-scaling fared best in association analyses. PMID:26485044

  13. What information on measurement uncertainty should be communicated to clinicians, and how?

    PubMed

    Plebani, Mario; Sciacovelli, Laura; Bernardi, Daniela; Aita, Ada; Antonelli, Giorgia; Padoan, Andrea

    2018-02-02

    The communication of laboratory results to physicians and the quality of reports represent fundamental requirements of the post-analytical phase in order to assure the right interpretation and utilization of laboratory information. Accordingly, the International Standard for clinical laboratories accreditation (ISO 15189) requires that "laboratory reports shall include the information necessary for the interpretation of the examination results". Measurement uncertainty (MU) is an inherent property of any quantitative measurement result which express the lack of knowledge of the true value and quantify the uncertainty of a result, incorporating the factors known to influence it. Even if the MU is not included in the report attributes of ISO 15189 and cannot be considered a post-analytical requirement, it is suggested as an information which should facilitate an appropriate interpretation of quantitative results (quantity values). Therefore, MU has two intended uses: for laboratory professionals, it gives information about the quality of measurements, providing evidence of the compliance with analytical performance characteristics; for physicians (and patients) it may help in interpretation of measurement results, especially when values are compared with reference intervals or clinical decision limits, providing objective information. Here we describe the way that MU should be added to laboratory reports in order to facilitate the interpretation of laboratory results and connecting efforts performed within laboratory to provide more accurate and reliable results with a more objective tool for their interpretation by physicians. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  14. Iodine intake by adult residents of a farming area in Iwate Prefecture, Japan, and the accuracy of estimated iodine intake calculated using the Standard Tables of Food Composition in Japan.

    PubMed

    Nakatsuka, Haruo; Chiba, Keiko; Watanabe, Takao; Sawatari, Hideyuki; Seki, Takako

    2016-11-01

    Iodine intake by adults in farming districts in Northeastern Japan was evaluated by two methods: (1) government-approved food composition tables based calculation and (2) instrumental measurement. The correlation between these two values and a regression model for the calibration of calculated values was presented. Iodine intake was calculated, using the values in the Japan Standard Tables of Food Composition (FCT), through the analysis of duplicate samples of complete 24-h food consumption for 90 adult subjects. In cases where the value for iodine content was not available in the FCT, it was assumed to be zero for that food item (calculated values). Iodine content was also measured by ICP-MS (measured values). Calculated and measured values rendered geometric means (GM) of 336 and 279 μg/day, respectively. There was no statistically significant (p > 0.05) difference between calculated and measured values. The correlation coefficient was 0.646 (p < 0.05). With this high correlation coefficient, a simple regression line can be applied to estimate measured value from calculated value. A survey of the literature suggests that the values in this study were similar to values that have been reported to date for Japan, and higher than those for other countries in Asia. Iodine intake of Japanese adults was 336 μg/day (GM, calculated) and 279 μg/day (GM, measured). Both values correlated so well, with a correlation coefficient of 0.646, that a regression model (Y = 130.8 + 1.9479X, where X and Y are measured and calculated values, respectively) could be used to calibrate calculated values.

  15. Interlaboratory comparison of reference materials for nitrogen-isotope-ratio measurements

    USGS Publications Warehouse

    Böhlke, John Karl; Coplen, Tyler B.

    1995-01-01

    Aliquots of seven different reference materials were distributed for an interlaboratory comparison of stable nitrogen-isotope-ratio measurements. Results from 15 laboratories were compiled and evaluated selectively to yield provisional values of 515N for each material, i, with respect to atmospheric N2 (o1SN,7air). The 515N values reported by the different laboratories are correlated in such a way that some of the major discrepancies may be removed by normalization (/. e., by altering the length of the ô N scale for each laboratory by an amount defined by local measurements of reference materials with extreme values).

  16. Political-economic values and the relationship between socioeconomic status and self-esteem.

    PubMed

    Malka, Ariel; Miller, Dale T

    2007-02-01

    Values concerning the distribution of wealth are an important aspect of identity for many Americans, and such values may therefore influence how Americans experience their own socioeconomic status (SES). Based on this proposition, the present research examines political-economic values as a moderator of the relationship between SES and self-esteem. Results supported the hypothesis that there is a stronger relationship between SES and self-esteem among individuals who report relatively inegalitarian values than among individuals who report relatively egalitarian values. This result was replicated using both objective and subjective measures of SES. Implications of the present findings for the study of values and well-being, psychological conflict, and the influence of economic factors on self-esteem are discussed.

  17. Test-Retest Reliability of Self-Reported Sexual Health Measures among US Hispanic Adolescents

    ERIC Educational Resources Information Center

    Jerman, Petra; Berglas, Nancy F.; Rohrbach, Louise A.; Constantine, Norman A.

    2016-01-01

    Objective: Although Hispanic adolescents in the USA are often the focus of sexual health interventions, their response to survey measures has rarely been assessed within evaluation studies. This study documents the test-retest reliability of a wide range of self-reported sexual health values, attitudes, knowledge and behaviours among Hispanic…

  18. The Feasibility of Using Questionnaires and Accelerometers to Measure Physical Activity and Sedentary Behavior Among Inpatient Adults With Mental Illness.

    PubMed

    Fraser, Sarah J; Chapman, Justin J; Brown, Wendy J; Whiteford, Harvey A; Burton, Nicola W

    2016-05-01

    The aim of this study was to assess the feasibility of using questionnaires and accelerometers to measure physical activity and sedentary behavior among inpatient adults with mental illness. Participants completed a physical activity and sitting time questionnaire and wore an accelerometer for 7 consecutive days. Feasibility was assessed in terms of participant engagement, self-reported ease/ difficulty of completing study components, extreme self-report data values and adherence to accelerometer wear time criteria. Ease/difficulty ratings were examined by level of distress. 177 inpatients were invited to the study, 101 completed the questionnaires and 36 provided valid accelerometry data. Participants found it more difficult to complete sitting time and physical activity questionnaires than to wear the accelerometer during waking hours (z = 3.787, P < .001; z = 2.824, P = .005 respectively). No significant differences were found in ease/ difficulty ratings by level of distress for any of the study components. Extreme values for self-reported sitting time were identified in 27% of participants. Inpatient adults with mental illness can engage with self-report and objective methods of measuring physical activity and sedentary behavior. They were initially less willing to participate in objective measurement, which may however be more feasible than self-report measures.

  19. Critical laboratory values in hemostasis: toward consensus.

    PubMed

    Lippi, Giuseppe; Adcock, Dorothy; Simundic, Ana-Maria; Tripodi, Armando; Favaloro, Emmanuel J

    2017-09-01

    The term "critical values" can be defined to entail laboratory test results that significantly lie outside the normal (reference) range and necessitate immediate reporting to safeguard patient health, as well as those displaying a highly and clinically significant variation compared to previous data. The identification and effective communication of "highly pathological" values has engaged the minds of many clinicians, health care and laboratory professionals for decades, since these activities are vital to good laboratory practice. This is especially true in hemostasis, where a timely and efficient communication of critical values strongly impacts patient management. Due to the heterogeneity of available data, this paper is hence aimed to analyze the state of the art and provide an expert opinion about the parameters, measurement units and alert limits pertaining to critical values in hemostasis, thus providing a basic document for future consultation that assists laboratory professionals and clinicians alike. KEY MESSAGES Critical values are laboratory test results significantly lying outside the normal (reference) range and necessitating immediate reporting to safeguard patient health. A broad heterogeneity exists about critical values in hemostasis worldwide. We provide here an expert opinion about the parameters, measurement units and alert limits pertaining to critical values in hemostasis.

  20. The role of attitudes about vaccine safety, efficacy, and value in explaining parents' reported vaccination behavior.

    PubMed

    Lavail, Katherine Hart; Kennedy, Allison Michelle

    2013-10-01

    To explain vaccine confidence as it related to parents' decisions to vaccinate their children with recommended vaccines, and to develop a confidence measure to efficiently and effectively predict parents' self-reported vaccine behaviors. A sample of parents with at least one child younger than 6 years (n = 376) was analyzed using data from the HealthStyles 2010 survey. Questions were grouped into block variables to create three confidence constructs: value, safety, and efficacy. Regression equations controlling for demographic characteristics were used to identify the confidence construct(s) that best predicted parents' self-reported vaccination decisions (accept all, some, or none of the recommended childhood vaccines). Among the three constructs evaluated, confidence in the value of vaccines, that is the belief that vaccines are important and vaccinating one's children is the right thing to do, was the best predictor of parents' vaccine decisions, F(2, 351) = 119.199, p < .001. When combined into a block variable for analysis, two survey items measuring confidence in the value of vaccines accounted for 40% of the variance in parents' self-reported vaccine decisions. Confidence in the safety or efficacy of vaccines failed to account for additional significant variance in parent-reported vaccination behavior. Confidence in the value of vaccines is a helpful predictor of parent-reported vaccination behavior. Attitudinal constructs of confidence in the safety and efficacy of vaccines failed to account for additional significant variance in parents' vaccination behaviors. Future research should assess the role of vaccine knowledge and tangible barriers, such as access and cost, to further explain parents' vaccination behaviors.

  1. SUPPLEMENTARY COMPARISON: APMP.EM-S6: Bilateral supplementary comparison of resistance

    NASA Astrophysics Data System (ADS)

    Charoensook, Ajchara; Jassadajin, Chaiwat; Chen, Henry; Ricketts, Brian

    2004-01-01

    A bilateral supplementary comparison of resistance, APMP.EM-S6, was conducted between the National Institute of Metrology Thailand (NIMT) and the CSIRO National Measurement Laboratory of Australia (NML). The comparison covered seven values of resistance, 0.1 Ω, 1 Ω, 100 Ω, 10 kΩ, 100 kΩ, 1 MΩ and 100 MΩ. The 0.1 Ω resistor was a YEW type 2792, the 100 MΩ resistor was an IET type SRC and the other five resistors were Fluke type 742A. The resistors were supplied by NIMT, and NML was the pilot laboratory for the comparison. The measurements for the comparison were made between December 2003 and April 2004. The resistors were measured on three separate occasions by NIMT and between each of these occasions the resistors were sent to NML for measurement. The resistors of nominal values 0.1 Ω, 1 Ω, 100 Ω and 10 kΩ were measured as four-terminal resistors while the 100 kΩ, 1 MΩ and 100 MΩ resistors were measured as two-terminal resistors. The quantity En (the absolute value of the difference between the values obtained at the two laboratories divided by the root sum square of the expanded uncertainties of the two values) was calculated for each resistance value used in the comparison. In all cases En was less than 0.5. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the Mutual Recognition Arrangement (MRA).

  2. Future Performance Trend Indicators: A Current Value Approach to Human Resources Accounting. Report II: Internal Consistencies and Relationships to Performance in Organization VI. Technical Report.

    ERIC Educational Resources Information Center

    Pecorella, Patricia A.; Bowers, David G.

    Conventional accounting systems provide no indication as to what conditions and events lead to reported outcomes, since they traditionally do not include measurements of the human organization and its relationship to events at the outcome stage. Human resources accounting is used to measure these additional types of data. This research is…

  3. Empathy, values, morality and Asperger's syndrome.

    PubMed

    Hirvelä, Shari; Helkama, Klaus

    2011-12-01

    The aims of this study were, first, to re-address the issue of empathy among people with autism conditions; second, to explore the relationships between empathy and values among autistic populations and controls; and third, to explore the capacity for moral agency among those affected by autism. We compared responses of an Asperger group (N = 41) and a control group (N = 139) to measures of self-reported empathy (Davis's IRI) and value priorities (Schwartz's PVQ). Control group results were largely in line with previous studies, such that empathy subscales of perspective taking and empathic concern showed their strongest positive and negative relations to the Schwartz self-transcendence/self-enhancement dimensions. Results for the Asperger group showed that although on the one hand there were self-reported difficulties in perspective taking and the cognitive recognition of affect, and that on the other hand there were less connections between the empathy and value measures, there was nevertheless a comparable prioritization of moral values. Conclusions suggest that different people may acquire moral values through different mechanisms. © 2011 The Authors. Scandinavian Journal of Psychology © 2011 The Scandinavian Psychological Associations.

  4. Expensing stock options: a fair-value approach.

    PubMed

    Kaplan, Robert S; Palepu, Krishna G

    2003-12-01

    Now that companies such as General Electric and Citigroup have accepted the premise that employee stock options are an expense, the debate is shifting from whether to report options on income statements to how to report them. The authors present a new accounting mechanism that maintains the rationale underlying stock option expensing while addressing critics' concerns about measurement error and the lack of reconciliation to actual experience. A procedure they call fair-value expensing adjusts and eventually reconciles cost estimates made at grant date with subsequent changes in the value of the options, and it does so in a way that eliminates forecasting and measurement errors over time. The method captures the chief characteristic of stock option compensation--that employees receive part of their compensation in the form of a contingent claim on the value they are helping to produce. The mechanism involves creating entries on both the asset and equity sides of the balance sheet. On the asset side, companies create a prepaid-compensation account equal to the estimated cost of the options granted; on the owners'-equity side, they create a paid-in capital stock-option account for the same amount. The prepaid-compensation account is then expensed through the income statement, and the stock option account is adjusted on the balance sheet to reflect changes in the estimated fair value of the granted options. The amortization of prepaid compensation is added to the change in the option grant's value to provide the total reported expense of the options grant for the year. At the end of the vesting period, the company uses the fair value of the vested option to make a final adjustment on the income statement to reconcile any difference between that fair value and the total of the amounts already reported.

  5. Questionnaire Predictors of Atopy in a US Population Sample: Findings From the National Health and Nutrition Examination Survey, 2005–2006

    PubMed Central

    Hoppin, Jane A.; Jaramillo, Renee; Salo, Paivi; Sandler, Dale P.; London, Stephanie J.; Zeldin, Darryl C.

    2011-01-01

    Allergic conditions and biochemical measures are both used to characterize atopy. To assess questionnaires’ ability to predict biochemical measures of atopy, the authors used data on 5 allergic conditions (allergy, hay fever, eczema, rhinitis, and itchy rash) and serum-specific immunoglobulin E (IgE) levels from the 2005–2006 National Health and Nutrition Examination Survey. Atopy was defined as 1 or more positive specific IgEs (≥0.35 kU/L). Questionnaire responses were assessed for sensitivity, specificity, and positive and negative predictive values for atopy. In this population-based US sample, 44% of participants were specific IgE-positive and 53% reported at least 1 allergic condition. Discordance between atopy and allergic conditions was considerable; 37% of persons with atopy reported no allergic condition, and 48% of persons who reported an allergic condition were not atopic. Thus, no combination of self-reported allergic conditions achieved both high sensitivity and high specificity for IgE. The positive predictive value of reported allergic conditions for atopy ranged from 50% for eczema to 72% for hay fever, while the negative predictive value ranged from 57% for eczema to 65% for any condition. Given the high proportion of asymptomatic participants who were specific IgE-positive and persons who reported allergic conditions but were specific IgE-negative, it is unlikely that questionnaires will ever capture the same participants as those found to be atopic by biochemical measures. PMID:21273397

  6. Interlaboratory comparison of fluorocarbons-11, -12, methylchloroform and nitrous oxide measurements

    NASA Technical Reports Server (NTRS)

    Rasmussen, R. A.; Khalil, M. A. K.

    1981-01-01

    Measurements conducted by 19 participating laboratories were considered in the reported interlaboratory comparison study. The results show that there is considerable disagreement among laboratories regarding the absolute concentrations of all four trace gases (CCl3F, CCl2F2, H3CCl3, N2O). The magnitude of this disagreement is discussed. Laboratories in Group II showed considerable disagreement among themselves. Their results were scattered within large intervals of concentration. Laboratories in Group I (using common standards) were in excellent (+ or - 5%) agreement among themselves. A systematic disagreement was noted between Groups I and II laboratories. Generally, the mean values of concentrations determined from the measurements of Group II laboratories were lower than the mean values reported by Group I laboratories.

  7. Medicare Program; Prospective Payment System and Consolidated Billing for Skilled Nursing Facilities for FY 2017, SNF Value-Based Purchasing Program, SNF Quality Reporting Program, and SNF Payment Models Research. Final rule.

    PubMed

    2016-08-05

    This final rule updates the payment rates used under the prospective payment system (PPS) for skilled nursing facilities (SNFs) for fiscal year (FY) 2017. In addition, it specifies a potentially preventable readmission measure for the Skilled Nursing Facility Value-Based Purchasing Program (SNF VBP), and implements requirements for that program, including performance standards, a scoring methodology, and a review and correction process for performance information to be made public, aimed at implementing value-based purchasing for SNFs. Additionally, this final rule includes additional polices and measures in the Skilled Nursing Facility Quality Reporting Program (SNF QRP). This final rule also responds to comments on the SNF Payment Models Research (PMR) project.

  8. Challenges in Measuring Teachers' Knowledge

    ERIC Educational Resources Information Center

    Fauskanger, Janne

    2015-01-01

    Mathematical knowledge for teaching (MKT) measures have been widely adopted by researchers. Critics have debated the value of such measures and questioned the type of knowledge that these access. This article reports on a study where the challenges in measuring teachers' knowledge were illuminated through investigating relationships between the…

  9. Conformational ordering of biomolecules in the gas phase: nitrogen collision cross sections measured on a prototype high resolution drift tube ion mobility-mass spectrometer.

    PubMed

    May, Jody C; Goodwin, Cody R; Lareau, Nichole M; Leaptrot, Katrina L; Morris, Caleb B; Kurulugama, Ruwan T; Mordehai, Alex; Klein, Christian; Barry, William; Darland, Ed; Overney, Gregor; Imatani, Kenneth; Stafford, George C; Fjeldsted, John C; McLean, John A

    2014-02-18

    Ion mobility-mass spectrometry measurements which describe the gas-phase scaling of molecular size and mass are of both fundamental and pragmatic utility. Fundamentally, such measurements expand our understanding of intrinsic intramolecular folding forces in the absence of solvent. Practically, reproducible transport properties, such as gas-phase collision cross-section (CCS), are analytically useful metrics for identification and characterization purposes. Here, we report 594 CCS values obtained in nitrogen drift gas on an electrostatic drift tube ion mobility-mass spectrometry (IM-MS) instrument. The instrument platform is a newly developed prototype incorporating a uniform-field drift tube bracketed by electrodynamic ion funnels and coupled to a high resolution quadrupole time-of-flight mass spectrometer. The CCS values reported here are of high experimental precision (±0.5% or better) and represent four chemically distinct classes of molecules (quaternary ammonium salts, lipids, peptides, and carbohydrates), which enables structural comparisons to be made between molecules of different chemical compositions for the rapid "omni-omic" characterization of complex biological samples. Comparisons made between helium and nitrogen-derived CCS measurements demonstrate that nitrogen CCS values are systematically larger than helium values; however, general separation trends between chemical classes are retained regardless of the drift gas. These results underscore that, for the highest CCS accuracy, care must be exercised when utilizing helium-derived CCS values to calibrate measurements obtained in nitrogen, as is the common practice in the field.

  10. Conformational Ordering of Biomolecules in the Gas Phase: Nitrogen Collision Cross Sections Measured on a Prototype High Resolution Drift Tube Ion Mobility-Mass Spectrometer

    PubMed Central

    2014-01-01

    Ion mobility-mass spectrometry measurements which describe the gas-phase scaling of molecular size and mass are of both fundamental and pragmatic utility. Fundamentally, such measurements expand our understanding of intrinsic intramolecular folding forces in the absence of solvent. Practically, reproducible transport properties, such as gas-phase collision cross-section (CCS), are analytically useful metrics for identification and characterization purposes. Here, we report 594 CCS values obtained in nitrogen drift gas on an electrostatic drift tube ion mobility-mass spectrometry (IM-MS) instrument. The instrument platform is a newly developed prototype incorporating a uniform-field drift tube bracketed by electrodynamic ion funnels and coupled to a high resolution quadrupole time-of-flight mass spectrometer. The CCS values reported here are of high experimental precision (±0.5% or better) and represent four chemically distinct classes of molecules (quaternary ammonium salts, lipids, peptides, and carbohydrates), which enables structural comparisons to be made between molecules of different chemical compositions for the rapid “omni-omic” characterization of complex biological samples. Comparisons made between helium and nitrogen-derived CCS measurements demonstrate that nitrogen CCS values are systematically larger than helium values; however, general separation trends between chemical classes are retained regardless of the drift gas. These results underscore that, for the highest CCS accuracy, care must be exercised when utilizing helium-derived CCS values to calibrate measurements obtained in nitrogen, as is the common practice in the field. PMID:24446877

  11. Precise Determination of the Intensity of 226Ra Alpha Decay to the 186 keV Excited State

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    S.P. LaMont; R.J. Gehrke; S.E. Glover

    There is a significant discrepancy in the reported values for the emission probability of the 186 keV gamma-ray resulting from the alpha decay of 226 Ra to 186 keV excited state of 222 Rn. Published values fall in the range of 3.28 to 3.59 gamma-rays per 100 alpha-decays. An interesting observation is that the lower value, 3.28, is based on measuring the 186 keV gamma-ray intensity relative to the 226 Ra alpha-branch to the 186 keV level. The higher values, which are close to 3.59, are based on measuring the gamma-ray intensity from mass standards of 226 Ra that aremore » traceable to the mass standards prepared by HÓNIGSCHMID in the early 1930''s. This discrepancy was resolved in this work by carefully measuring the 226 Ra alpha-branch intensities, then applying the theoretical E2 multipolarity internal conversion coefficient of 0.692±0.007 to calculate the 186 keV gamma-ray emission probability. The measured value for the alpha branch to the 186 keV excited state was (6.16±0.03)%, which gives a 186 keV gamma-ray emission probability of (3.64±0.04)%. This value is in excellent agreement with the most recently reported 186 keV gamma-ray emission probabilities determined using 226 Ra mass standards.« less

  12. Handheld Synthetic Array Final Report, Part A

    DTIC Science & Technology

    2014-12-01

    Measurement Unit 4/143 IEEE Institute of Electrical and Electronics Engineers KF Kalman Filter KL Kullback - Leibler LAMBDA Least-squares... testing the algorithms for the LOS AN wireless beamforming. Given a good set of feature points, the ego-motion is sufficiently accurate to... of little value to the overall SLAM and the RSS observables are used instead. While individual RSS measurements are low in information value, the

  13. Fabrication of setup for high temperature thermal conductivity measurement.

    PubMed

    Patel, Ashutosh; Pandey, Sudhir K

    2017-01-01

    In this work, we report the fabrication of an experimental setup for high temperature thermal conductivity (κ) measurement. It can characterize samples with various dimensions and shapes. Steady state based axial heat flow technique is used for κ measurement. Heat loss is measured using parallel thermal conductance technique. Simple design, lightweight, and small size sample holder is developed by using a thin heater and limited components. Low heat loss value is achieved by using very low thermal conductive insulator block with small cross-sectional area. Power delivered to the heater is measured accurately by using 4-wire technique and for this, the heater is developed with 4 wires. This setup is validated by using Bi 0.36 Sb 1.45 Te 3 , polycrystalline bismuth, gadolinium, and alumina samples. The data obtained for these samples are found to be in good agreement with the reported data. The maximum deviation of 6% in the value κ is observed. This maximum deviation is observed with the gadolinium sample. We also report the thermal conductivity of polycrystalline tellurium from 320 K to 550 K and the nonmonotonous behavior of κ with temperature is observed.

  14. Primary Care Practices' Abilities And Challenges In Using Electronic Health Record Data For Quality Improvement.

    PubMed

    Cohen, Deborah J; Dorr, David A; Knierim, Kyle; DuBard, C Annette; Hemler, Jennifer R; Hall, Jennifer D; Marino, Miguel; Solberg, Leif I; McConnell, K John; Nichols, Len M; Nease, Donald E; Edwards, Samuel T; Wu, Winfred Y; Pham-Singer, Hang; Kho, Abel N; Phillips, Robert L; Rasmussen, Luke V; Duffy, F Daniel; Balasubramanian, Bijal A

    2018-04-01

    Federal value-based payment programs require primary care practices to conduct quality improvement activities, informed by the electronic reports on clinical quality measures that their electronic health records (EHRs) generate. To determine whether EHRs produce reports adequate to the task, we examined survey responses from 1,492 practices across twelve states, supplemented with qualitative data. Meaningful-use participation, which requires the use of a federally certified EHR, was associated with the ability to generate reports-but the reports did not necessarily support quality improvement initiatives. Practices reported numerous challenges in generating adequate reports, such as difficulty manipulating and aligning measurement time frames with quality improvement needs, lack of functionality for generating reports on electronic clinical quality measures at different levels, discordance between clinical guidelines and measures available in reports, questionable data quality, and vendors that were unreceptive to changing EHR configuration beyond federal requirements. The current state of EHR measurement functionality may be insufficient to support federal initiatives that tie payment to clinical quality measures.

  15. Reported maternal tendencies predict the reward value of infant facial cuteness, but not cuteness detection

    PubMed Central

    Hahn, Amanda C.; DeBruine, Lisa M.; Jones, Benedict C.

    2015-01-01

    The factors that contribute to individual differences in the reward value of cute infant facial characteristics are poorly understood. Here we show that the effect of cuteness on a behavioural measure of the reward value of infant faces is greater among women reporting strong maternal tendencies. By contrast, maternal tendencies did not predict women's subjective ratings of the cuteness of these infant faces. These results show, for the first time, that the reward value of infant facial cuteness is greater among women who report being more interested in interacting with infants, implicating maternal tendencies in individual differences in the reward value of infant cuteness. Moreover, our results indicate that the relationship between maternal tendencies and the reward value of infant facial cuteness is not due to individual differences in women's ability to detect infant cuteness. This latter result suggests that individual differences in the reward value of infant cuteness are not simply a by-product of low-cost, functionless biases in the visual system. PMID:25740842

  16. Reference Values for Weight, Height, Head Circumference, and Body Mass Index in Turkish Children.

    PubMed

    Neyzi, Olcay; Bundak, Rüveyde; Gökçay, Gülbin; Günöz, Hülya; Furman, Andrzej; Darendeliler, Feyza; Baş, Firdevs

    2015-12-01

    This study aimed to integrate the existing updated reference standards for the growth of Turkish infants and children and to compare these values with World Health Organization (WHO) reference data, data from some European countries, and also with previous local data. Weight, height, and head circumference measurements were obtained on 2,391 boys and 2,102 girls who were regular attenders of a well child clinic and on 1,100 boys and 1,020 girls attending schools in relatively well-off districts in İstanbul. Mean number of measurements per child was 8.2±3.6 in the age group 0-5 years and 5.5±3.3 in the age group 6-18 years. All children were from well-to-do families and all were healthy. All measurements with the exception of measurements at birth, which were based on reported values, were done by trained personnel. The LMS method was used in the analyses and in the construction of the percentile charts. There is an increase in weight for age and body mass index values for age starting in prepubertal ages, indicating an increasing trend for obesity. Compared to WHO reference data, weight and height values in Turkish children were slightly higher in infants and in children younger than 5 years, while they showed similarity to those reported for children from Norway and Belgium. Head circumference values, which were slightly higher than the WHO references in the first 5 years, were comparable to the data on Belgian and Norwegian children in the first 9 years of life. At older ages, Turkish children showed higher values for head circumference. The relatively larger head circumference values were interpreted to reflect a genetic characteristic.

  17. Thoracic limb alignment in healthy labrador retrievers: evaluation of standing versus recumbent frontal plane radiography.

    PubMed

    Goodrich, Zachary J; Norby, Bo; Eichelberger, Bunita M; Friedeck, Wade O; Callis, Hollye N; Hulse, Don A; Kerwin, Sharon C; Fox, Derek B; Saunders, W Brian

    2014-10-01

    To report thoracic limb alignment values in healthy dogs; to determine if limb alignment values are significantly different when obtained from standing versus recumbent radiographic projections. Prospective cross-sectional study. Labrador Retrievers (n = 45) >15 months of age. Standing and recumbent radiographs were obtained and limb montages were randomized before analysis by a single investigator blinded to dog, limb, and limb position. Twelve limb alignment values were determined using the CORA methodology. Measurements were performed in triplicate and intra-observer variability was evaluated by intra-class correlation coefficient (ICC). Limb alignment values were reported as mean ± SD and 95% confidence intervals. Linear mixed models were used to determine if significant associations existed between limb alignment values and limb, limb position, gender, age, weight, and body condition score. There were significant differences in standing and recumbent limb alignment values for all values except elbow mechanical axis deviation (eMAD). Limb, gender, age, body weight, and body condition score had no effect. ICC values ranged from 0.522 to 0.758, indicating moderate to substantial agreement for repeated measurements by a single investigator. Limb alignment values are significantly different when determined from standing versus recumbent radiographs in healthy Labrador Retrievers. © Copyright 2014 by The American College of Veterinary Surgeons.

  18. 10 CFR 300.9 - Reporting and recordkeeping requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... these guidelines, all reports must conform to the measurement methods established by the Technical... justification. (3) If a change in calculation methods (for inventories or reductions) is made for a particular year, the reporting entity must, if feasible, revise its base value to assure methodological...

  19. 10 CFR 300.9 - Reporting and recordkeeping requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... these guidelines, all reports must conform to the measurement methods established by the Technical... justification. (3) If a change in calculation methods (for inventories or reductions) is made for a particular year, the reporting entity must, if feasible, revise its base value to assure methodological...

  20. 10 CFR 300.9 - Reporting and recordkeeping requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... these guidelines, all reports must conform to the measurement methods established by the Technical... justification. (3) If a change in calculation methods (for inventories or reductions) is made for a particular year, the reporting entity must, if feasible, revise its base value to assure methodological...

  1. 10 CFR 300.9 - Reporting and recordkeeping requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... these guidelines, all reports must conform to the measurement methods established by the Technical... justification. (3) If a change in calculation methods (for inventories or reductions) is made for a particular year, the reporting entity must, if feasible, revise its base value to assure methodological...

  2. 10 CFR 300.9 - Reporting and recordkeeping requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... these guidelines, all reports must conform to the measurement methods established by the Technical... justification. (3) If a change in calculation methods (for inventories or reductions) is made for a particular year, the reporting entity must, if feasible, revise its base value to assure methodological...

  3. Modulation of Beta-catenin Activity With PKD1 Prostate Cancer

    DTIC Science & Technology

    2009-04-01

    mutated site as a negative control (FOPFlash) with pRL-TK ( Renilla luciferase) in C4-2- PKD1-GFP cells activated with Bryostatin 1 or DMSO. The...firefly and Renilla luciferase activities were measured with the Dual-Luciferase Reporter (DLR) Assay System. After normalizing the firefly luciferase...activity to that of Renilla luciferase, the FOPFlash reporter plasmid luciferase values were subtracted from the normalized values obtained with the

  4. Improving health care, Part 1: The clinical value compass.

    PubMed

    Nelson, E C; Mohr, J J; Batalden, P B; Plume, S K

    1996-04-01

    CLINICAL VALUE COMPASS APPROACH: The clinical Value Compass, named to reflect its similarity in layout to a directional compass, has at its four cardinal points (1) functional status, risk status, and well-being; (2) costs; (3) satisfaction with health care and perceived benefit; and (4) clinical outcomes. To manage and improve the value of health care services, providers will need to measure the value of care for similar patient populations, analyze the internal delivery processes, run tests of changed delivery processes, and determine if these changes lead to better outcomes and lower costs. GETTING STARTED--OUTCOMES AND AIM: In the case example, the team's aim is "to find ways to continually improve the quality and value of care for AMI (acute myocardial infection) patients." VALUE MEASURES--SELECT A SET OF OUTCOME AND COST MEASURES: Four to 12 outcome and cost measures are sufficient to get started. In the case example, the team chose 1 or more measures for each quadrant of the value compass. An operational definition is a clearly specified method explaining how to measure a variable. Measures in the case example were based on information from the medical record, administrative and financial records, and patient reports and ratings at eight weeks postdischarge. Measurement systems that quantify the quality of processes and results of care are often add-ons to routine care delivery. However, the process of measurement should be intertwined with the process of care delivery so that front-line providers are involved in both managing the patient and measuring the process and related outcomes and costs.

  5. Manning's roughness coefficient for Illinois streams

    USGS Publications Warehouse

    Soong, David T.; Prater, Crystal D.; Halfar, Teresa M.; Wobig, Loren A.

    2012-01-01

    Manning's roughness coefficients for 43 natural and constructed streams in Illinois are reported and displayed on a U.S. Geological Survey Web site. At a majority of the sites, discharge and stage were measured, and corresponding Manning's coefficients—the n-values—were determined at more than one river discharge. The n-values discussed in this report are computed from data representing the stream reach studied and, therefore, are reachwise values. Presentation of the resulting n-values takes a visual-comparison approach similar to the previously published Barnes report (1967), in which photographs of channel conditions, description of the site, and the resulting n-values are organized for each site. The Web site where the data can be accessed and are displayed is at URL http://il.water.usgs.gov/proj/nvalues/.

  6. Precise Measurements of the Masses of Cs, Rb and Na A New Route to the Fine Structure Constant

    NASA Astrophysics Data System (ADS)

    Rainville, Simon; Bradley, Michael P.; Porto, James V.; Thompson, James K.; Pritchard, David E.

    2001-01-01

    We report new values for the atomic masses of the alkali 133Cs, 87Rb, 85Rb, and 23Na with uncertainties ≤ 0.2 ppb. These results, obtained using Penning trap single ion mass spectrometry, are typically two orders of magnitude more accurate than previously measured values. Combined with values of h/m atom from atom interferometry measurements and accurate wavelength measurements for different atoms, these values will lead to new ppb-level determinations of the molar Planck constant N A h and the fine structure constant α. This route to α is based on simple physics. It can potentially achieve the several ppb level of accuracy needed to test the QED determination of α extracted from measurements of the electron g factor. We also demonstrate an electronic cooling technique that cools our detector and ion below the 4 K ambient temperature. This technique improves by about a factor of three our ability to measure the ion's axial motion.

  7. The Reliability and Validity of Salivation as a Measure of Individual Differences in Intrinsic Arousal. Report from the Project on Motivation and Individual Differences in Learning and Retention.

    ERIC Educational Resources Information Center

    Farley, Frank H.; And Others

    Two studies were reported which attempted to estimate the stability and construct validity of human salivary response as a measure of individual differences (IDs) in physiological arousal. Twenty-second base line estimates and 20-second response levels to four drops of lemon juice were measured, with the former value being removed from the latter…

  8. Microhardness of light- and dual-polymerizable luting resins polymerized through 7.5-mm-thick endocrowns.

    PubMed

    Gregor, Ladislav; Bouillaguet, Serge; Onisor, Ioana; Ardu, Stefano; Krejci, Ivo; Rocca, Giovanni Tommaso

    2014-10-01

    The complete polymerization of luting resins through thick indirect restorations is still questioned. The purpose of this study was to evaluate the degree of polymerization of light- and dual-polymerizable luting resins under thick indirect composite resin and ceramic endocrowns by means of Vickers microhardness measurements. The Vickers microhardness measurements of a light-polymerizable microhybrid composite resin and a dual-polymerizable luting cement directly polymerized in a natural tooth mold for 40 seconds with a high-power light-emitting diode lamp (control) were compared with measurements after indirect irradiation through 7.5-mm-thick composite resin and ceramic endocrowns for 3 × 90 seconds. A test-to-control microhardness values ratio of 0.80 at a depth of 0.5 mm below the surface was assumed as the criterion for adequate conversion. For the Vickers microhardness measurements of a dual-polymerizable luting cement, no differences (P>.05) were found between Vickers microhardness control values and values reported after polymerization through composite resin and ceramic endocrowns. For The Vickers microhardness measurements (±SD) of a light-polymerizable microhybrid composite resin, control values were significantly (P<.05) higher (111 ±3.3) than those reported after polymerization through composite resin (100.5 ±3.8) and ceramic (99.7 ±2.3) endocrowns. However, the hardness values of The Vickers microhardness measurements of a light-polymerizable microhybrid composite resin polymerized through the endocrowns were approximately 10% to 12% lower than those of the control values. Two-way ANOVA showed the influence of the luting material on the Vickers microhardness values (P<.05). The effect of endocrown material was not significant (P>.05). Under the conditions of this in vitro study, Vickers microhardness values of the dual-polymerizable resin cement and the light-polymerizable restorative composite resin irradiated for 3 × 90 seconds with a high irradiance light-emitting diode lamp through 7.5-mm-thick endocrowns reached at least 80% of the control Vickers microhardness values, which means that both materials can be adequately polymerized when they are used for luting thick indirect restorations. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  9. Using Patient-Reported Information to Improve Clinical Practice.

    PubMed

    Schlesinger, Mark; Grob, Rachel; Shaller, Dale

    2015-12-01

    To assess what is known about the relationship between patient experience measures and incentives designed to improve care, and to identify how public policy and medical practices can promote patient-valued outcomes in health systems with strong financial incentives. Existing literature (gray and peer-reviewed) on measuring patient experience and patient-reported outcomes, identified from Medline and Cochrane databases; evaluations of pay-for-performance programs in the United States, Europe, and the Commonwealth countries. We analyzed (1) studies of pay-for-performance, to identify those including metrics for patient experience, and (2) studies of patient experience and of patient-reported outcomes to identify evidence of influence on clinical practice, whether through public reporting or private reporting to clinicians. First, we identify four forms of "patient-reported information" (PRI), each with distinctive roles shaping clinical practice: (1) patient-reported outcomes measuring self-assessed physical and mental well-being, (2) surveys of patient experience with clinicians and staff, (3) narrative accounts describing encounters with clinicians in patients' own words, and (4) complaints/grievances signaling patients' distress when treatment or outcomes fall short of expectations. Because these forms vary in crucial ways, each must be distinctively measured, deployed, and linked with financial incentives. Second, although the literature linking incentives to patients experience is limited, implementing pay-for-performance systems appears to threaten certain patient-valued aspects of health care. But incentives can be made compatible with the outcomes patients value if: (a) a sufficient portion of incentives is tied to patient-reported outcomes and experiences, (b) incentivized forms of PRI are complemented by other forms of patient feedback, and (c) health care organizations assist clinicians to interpret and respond to PRI. Finally, we identify roles for the public and private sectors in financing PRI and orchestrating an appropriate balance among its four forms. Unless public policies are attentive to patients' perspectives, stronger financial incentives for clinicians can threaten aspects of care that patients most value. Certain policy parameters are already clear, but additional research is required to clarify how best to collect patient narratives in varied settings, how to report narratives to consumers in conjunction with quantified metrics, and how to promote a "culture of learning" at the practice level that incorporates patient feedback. © Health Research and Educational Trust.

  10. Primary Care Practices’ Abilities And Challenges In Using Electronic Health Record Data For Quality Improvement

    PubMed Central

    Cohen, Deborah J.; Dorr, David A.; Knierim, Kyle; DuBard, C. Annette; Hemler, Jennifer R.; Hall, Jennifer D.; Marino, Miguel; Solberg, Leif I.; McConnell, K. John; Nichols, Len M.; Nease, Donald E.; Edwards, Samuel T.; Wu, Winfred Y.; Pham-Singer, Hang; Kho, Abel N.; Phillips, Robert L.; Rasmussen, Luke V.; Duffy, F. Daniel; Balasubramanian, Bijal A.

    2018-01-01

    Federal value-based payment programs require primary care practices to conduct quality improvement activities, informed by the electronic reports on clinical quality measures that their electronic health records (EHRs) generate. To determine whether EHRs produce reports adequate to the task, we examined survey responses from 1,492 practices across twelve states, supplemented with qualitative data. Meaningful-use participation, which requires the use of a federally certified EHR, was associated with the ability to generate reports—but the reports did not necessarily support quality improvement initiatives. Practices reported numerous challenges in generating adequate reports, such as difficulty manipulating and aligning measurement time frames with quality improvement needs, lack of functionality for generating reports on electronic clinical quality measures at different levels, discordance between clinical guidelines and measures available in reports, questionable data quality, and vendors that were unreceptive to changing EHR configuration beyond federal requirements. The current state of EHR measurement functionality may be insufficient to support federal initiatives that tie payment to clinical quality measures. PMID:29608365

  11. Do the EULAR Sjögren's syndrome outcome measures correlate with health status in primary Sjögren's syndrome?

    PubMed

    Lendrem, Dennis; Mitchell, Sheryl; McMeekin, Peter; Gompels, Luke; Hackett, Katie; Bowman, Simon; Price, Elizabeth; Pease, Colin T; Emery, Paul; Andrews, Jacqueline; Lanyon, Peter; Hunter, John; Gupta, Monica; Bombardieri, Michele; Sutcliffe, Nurhan; Pitzalis, Costantino; McLaren, John; Cooper, Annie; Regan, Marian; Giles, Ian; Isenberg, David; Saravanan, Vadivelu; Coady, David; Dasgupta, Bhaskar; McHugh, Neil; Young-Min, Steven; Moots, Robert; Gendi, Nagui; Akil, Mohammed; Griffiths, Bridget; Ng, Wan-Fai

    2015-04-01

    This study sets out to investigate the relationship between health status [EuroQol five-dimensions questionnaire (EQ-5D)] in primary SS and three of the European League Against Rheumatism (EULAR) SS outcome measures-the disease activity index (ESSDAI), the patient reported index (ESSPRI) and the sicca score. In particular, the goal was to establish whether there is a relationship between the EULAR outcome measures and quality of life. Health status was evaluated using a standardized measure developed by the EuroQol Group-the EQ5D. This permits calculation of two measures of health status: time trade-off (TTO) values and the EQ-5D visual analogue scale (VAS) scores. We used Spearman's rank correlation analysis to investigate the strength of association between health status and three EULAR measures of physician- and patient-reported disease activity in 639 patients from the UK primary SS registry (UKPSSR) cohort. This study demonstrates that the EULAR SS disease-specific outcome measures are significantly correlated with health outcome values (P < 0.001). Higher scores on the ESSDAI, EULAR sicca score and ESSPRI are associated with poorer health states-i.e. lower TTO values and lower VAS scores. While all three are significantly correlated with TTO values and EQ-5D VAS scores, the effect is strongest for the ESSPRI. This study provides further evidence supporting the use of ESSDAI, EULAR sicca score and ESSPRI measures in the clinic. We also discuss the need for disease-specific measures of health status and their comparison with standardized health outcome measures. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. CHARGE MEASUREMENTS ON INDIVIDUAL PARTICLES EXITING LABORATORY PRECIPITATORS WITH POSITIVE AND NEGATIVE CORONA AT VARIOUS TEMPERATURES

    EPA Science Inventory

    The paper reports measurements of charge values on individual particles exiting three different laboratory electrostatic precipitators (ESPs) in an experimental apparatus containing a Millikan cell. Dioctylphthalate (DOP) droplets and fly ash particles were measured at temperatur...

  13. Noncash Benefits. Methodological Review of Experimental Valuation Methods Indicates Many Problems Remain. Report to Congressional Requesters.

    ERIC Educational Resources Information Center

    General Accounting Office, Washington, DC. Program Evaluation and Methodology Div.

    Increasingly the poor have been receiving federal assistance through goods and services rather than cash. These goods and services have not been counted when measuring the income and poverty of the recipients. This report examines three proposals to change the manner in which poverty is measured. All include ways to calculate the value of noncash…

  14. The Effect of Self-Reported and Performance-Based Functional Impairment on Future Hospital Costs of Community-Dwelling Older Persons

    ERIC Educational Resources Information Center

    Reuben, David B.; Seeman, Teresa E.; Keeler, Emmett; Hayes, Risa P.; Bowman, Lee; Sewall, Ase; Hirsch, Susan H.; Wallace, Robert B.; Guralnik, Jack M.

    2004-01-01

    Purpose: We determined the prognostic value of self-reported and performance-based measurement of function, including functional transitions and combining different measurement approaches, on utilization. Design and Methods: Our cohort study used the 6th, 7th, and 10th waves of three sites of the Established Populations for Epidemiologic Studies…

  15. Comparison of pulmonary artery and central venous pressure waveform measurements via digital and graphic measurement methods.

    PubMed

    Ahrens, T S; Schallom, L

    2001-01-01

    Techniques to measure pulmonary artery (PA) pressure waveforms include digital measurement, graphic measurement, and freeze-cursor measurement. Previous studies reported the inaccuracy of digital and freeze-cursor measurements. However, many of the previous studies were small and did not thoroughly examine the circumstances of when digital measurements might be inaccurate. To compare digital measurements and graphic measurements of PA and central venous pressure (CVP) waveforms in patients with a variety of respiratory patterns, and to compare digital measurements and graphic measurements of CVPs in patients with abnormal or right ventricular waveforms. A total of 928 patients were enrolled in this study. Waveforms from the PA and CVP were collected from each patient. The monitor pressure value (digital measurement) printed on the recorded waveform was compared with the pressure value obtained by a graphic strip recording and measured by one of the primary investigators (graphic measurement). Digital measurements were found to be inaccurate in measuring waveforms in all respiratory categories and in measuring right ventricular waveforms. PA diastolic values and CVP values were the most inaccurately measured waveforms. Digital errors of more than 4 mm Hg were common. There were instances in which the monitor's digital measurement was substantially different from the graphically measured value. This difference has the potential to mislead interpretation of clinical situations. The monitor's ability to occasionally give digital measurement values similar to the graphic measurements may lead to a false sense of security in clinicians. Because the accuracy of the monitor is inconsistent, the bedside clinician should interpret waveforms through use of a graphic recording rather than rely on the digital measurement on the monitor.

  16. How Do We Value Postoperative Recovery?: A Systematic Review of the Measurement Properties of Patient-reported Outcomes After Abdominal Surgery.

    PubMed

    Fiore, Julio F; Figueiredo, Sabrina; Balvardi, Saba; Lee, Lawrence; Nauche, Bénédicte; Landry, Tara; Mayo, Nancy E; Feldman, Liane S

    2018-04-01

    To appraise the level of evidence supporting the measurement properties of patient-reported outcome measures (PROMs) in the context of postoperative recovery after abdominal surgery. There is growing interest in using PROMs to support value-based care in abdominal surgery; however, to draw valid conclusions regarding patient-reported outcomes data, PROMs with robust measurement properties are required. Eight databases (MEDLINE, EMBASE, Biosis, PsycINFO, The Cochrane Library, CINAHL, Scopus, Web of Science) were searched for studies focused on the measurement properties of PROMs in the context of recovery after abdominal surgery. The methodological quality of individual studies was evaluated using the consensus-based COSMIN checklist. Evidence supporting the measurement properties of each PROM was synthetized according to standardized criteria and compared against the International Society of Quality of Life Research minimum standards for the selection of PROMs for outcomes research. We identified 35 studies evaluating 22 PROMs [12 focused on nonspecific surgical populations (55%), 4 focused on abdominal surgery (18%), and 6 generic PROMs (27%)]. The great majority of the studies (74%) received only poor or fair quality ratings. Measurement properties of PROMs were predominantly supported by limited or unknown evidence. None of the PROMs fulfilled International Society of Quality of Life Research's minimum standards, hindering specific recommendations. There is very limited evidence supporting the measurement properties of existing PROMs used in the context of recovery after abdominal surgery. This precludes the use of these PROMs to support value-based surgical care. Further research is required to bridge this major knowledge gap. International Prospective Register of Systematic Reviews (PROSPERO): CRD42014014349.

  17. BCR®-701: a review of 10-years of sequential extraction analyses.

    PubMed

    Sutherland, Ross A

    2010-11-08

    A detailed quantitative analysis was performed on data presented in the literature that focused on the sequential extraction of cadmium (Cd), chromium (Cr), copper (Cu), nickel (Ni), lead (Pb) and zinc (Zn) from the certified reference material BCR-701 (lake sediment) using the three-step harmonized BCR(®) procedure. The accuracy of data reported in the literature, including precision and different measures of trueness, was assessed relative to the certified values for BCR-701. Forty data sets were accepted following extreme outlier removal, and statistically summarized with measures of central tendency, dispersion, and distribution form. In general, literature data were similar in their measurement precision to the expert laboratories used to certify the trace element contents in BCR-701. The overall median precision for literature reported data was 10% (range 6-19%), compared to certifying laboratories of 9% (range 4-33%). One measure of literature data trueness was assessed via a confirmatory approach using a robust bootstrap method. Only 22% of the comparisons indicated significantly different (all were lower) concentrations reported in the literature compared to certified values. The question of whether the differences are practically significant for environmental studies is raised. Bias was computed as a measure of trueness, and literature data were more frequently negatively biased, indicating lower concentrations reported in the literature for the six trace elements for the three-step sequential procedure compared to the certified values. However, 95% confidence intervals about the average bias for the 18 comparisons indicated only four instances when a mean bias of 0 (i.e., measured=certified) was not incorporated-suggesting statistical difference. Finally, Z-scores incorporating a Horwitz-type function were used to assess the general trueness of laboratory data. Of the 468 laboratory Z-score values computed, 92% were considered to be satisfactory, 5% were questionable, and 3% were unsatisfactory. A detailed examination of the methodology sections of the various studies showed that despite claiming adherence to the harmonized BCR sequential extraction protocol, significant deviations were commonly observed; particularly in moisture correction, sample mass, centrifugation specifics, shaking specifics, and incorporation of filtration. It is likely that failure to strictly adhere to the protocol adversely impacted accuracy, by increasing the degree of imprecision and resulting in more discrepant trueness values. Copyright © 2010 Elsevier B.V. All rights reserved.

  18. Measuring Virtual Simulations Value in Training Exercises - USMC Use Case

    DTIC Science & Technology

    2015-12-04

    and cost avoidance and Capt Jonathan Richardson, PM TRASYS, who was the primary author for the After-Action Documentation and Analysis Report ...REFERENCES Cermak J. & McGurk M. (2010, July). Putting a Value On Training. McKinsey Quarterly. Retrieved June 10, 2015 from http://www.mckinsey.com...www.hqmc.marines.mil/Portals/142/Docs/2015CPG_Color.pdf Gordon, S. & Cooley, T. (2013) Phase One Final Report : Cost Avoidance Study of USMC Simulation

  19. Development and Validation of Measures of Noncognitive College Student Potential. Research Report 2011-1

    ERIC Educational Resources Information Center

    Schmitt, Neal; Billington, Abigail; Keeney, Jessica; Reeder, Matthew; Pleskac, Timothy J.; Sinha, Ruchi; Zorzie, Mark

    2011-01-01

    Noncognitive attributes as the researchers have measured them do correlate with college GPA, but the incremental validity associated with these measures is relatively small. The noncognitive measures are correlated with other valued dimensions of student performance beyond the achievement reflected in college grades. There were much smaller…

  20. Volumetric and acoustical behaviour of sodium saccharin in aqueous system over temperature range (20.0-45.0)°C.

    PubMed

    Jamal, Muhammad Asghar; Rashad, Muhammad; Khosa, Muhammad Kaleem; Bhatti, Haq Nawaz

    2015-04-15

    Densities and ultrasonic velocity values for aqueous solutions of sodium saccharin (SS) has been measured as a function of concentration at 20.0-45.0 °C and atmospheric pressure using DSA-5000 M. The density and ultrasonic velocity values have been further used to calculate apparent molar volume, apparent specific volume, isentropic apparent molar compressibility and compressibility hydration numbers and reported. The values for apparent molar volume obtained at given temperatures showed negative deviations from Debye-Hückel limiting law and used as a direct measure of the ion-ion and ion-solvent interactions. The apparent specific volumes of the solute were calculated and it was found that these values of the investigated solutions lie on the borderline between the values reported for sweet substances. The sweetness response of the sweeteners is then explained in terms of their solution behaviours. Furthermore, the partial molar expansibility, its second derivative, (∂(2)V°/∂T(2)) as Hepler's constant and thermal expansion coefficient have been estimated. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Enthalpy measurement of coal-derived liquids. Combined quarterly technical progress reports, April-June 1979 and July-September 1979. [Effect of association

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kidnay, A.J.; Yesavage, V.F.

    1979-01-01

    Enthalpy measurements on a coal-derived naphtha and middle distillate, both produced by the SRC-II process, were made using flow calorimetry. The accuracy of the measurements, as reported by Omid, was within +- 1% of the measured enthalpy differences, ..delta..H. Experimental data for the naphtha were obtained over a pressure range of 100-300 psia and temperatures from 148/sup 0/ to 456/sup 0/F. The middle distillate enthalpy measurements were made in the pressure and temperature ranges of 130 to 1000 psia, and 157/sup 0/ to 675/sup 0/F, respectively. The methods of prediction of enthalpy developed for petroleum fractions were unsatisfactory when appliedmore » to the above data. A negative bias was observed in the predicted enthalpy values for several of the coal-liquids. Based on these results, it was theorized that the high experimental enthalpy values for coal-liquids were due to an energy of association attributed, primarily, to hydrogen-bonding effects. The petroleum-fraction enthalpy correlations were then tested on the experimental data for pure compounds, both associating and non-associating. The predicted values compared very well with the experimental results for non-associating model compounds. However, for associating model compounds the predicted enthalpy values were considerably lower than their experimental data. This served to confirm the basic premise that the high experimental enthalpy values, for model compounds and coal liquids, were a direct consequence of an energy of association attributed, primarily, to hydrogen-bonding effects.« less

  2. E/N effects on K0 values revealed by high precision measurements under low field conditions

    NASA Astrophysics Data System (ADS)

    Hauck, Brian C.; Siems, William F.; Harden, Charles S.; McHugh, Vincent M.; Hill, Herbert H.

    2016-07-01

    Ion mobility spectrometry (IMS) is used to detect chemical warfare agents, explosives, and narcotics. While IMS has a low rate of false positives, their occurrence causes the loss of time and money as the alarm is verified. Because numerous variables affect the reduced mobility (K0) of an ion, wide detection windows are required in order to ensure a low false negative response rate. Wide detection windows, however, reduce response selectivity, and interferents with similar K0 values may be mistaken for targeted compounds and trigger a false positive alarm. Detection windows could be narrowed if reference K0 values were accurately known for specific instrumental conditions. Unfortunately, there is a lack of confidence in the literature values due to discrepancies in the reported K0 values and their lack of reported error. This creates the need for the accurate control and measurement of each variable affecting ion mobility, as well as for a central accurate IMS database for reference and calibration. A new ion mobility spectrometer has been built that reduces the error of measurements affecting K0 by an order of magnitude less than ±0.2%. Precise measurements of ±0.002 cm2 V-1 s-1 or better have been produced and, as a result, an unexpected relationship between K0 and the electric field to number density ratio (E/N) has been discovered in which the K0 values of ions decreased as a function of E/N along a second degree polynomial trend line towards an apparent asymptote at approximately 4 Td.

  3. Mean lives of some astrophysically important excited levels in carbon, nitrogen and oxygen

    NASA Technical Reports Server (NTRS)

    Chang, M. W.; Bickel, W. S.

    1976-01-01

    A number of astrophysically important mean lives of levels in carbon, nitrogen and oxygen were measured with the beam-foil technique. New values are reported and compared with earlier theoretical and experimental values. Direct references to astrophysical applications are listed.

  4. TRANSITING THE SUN. II. THE IMPACT OF STELLAR ACTIVITY ON Lyα TRANSITS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Llama, J.; Shkolnik, E. L., E-mail: joe.llama@lowell.edu

    High-energy observations of the Sun provide an opportunity to test the limits of our ability to accurately measure the properties of transiting exoplanets in the presence of stellar activity. Here we insert the transit of a hot Jupiter into continuous disk integrated data of the Sun in Lyα from NASA’s Solar Dynamics Observatory/EVE instrument to assess the impact of stellar activity on the measured planet-to-star radius ratio (R{sub p}/R{sub ⋆}). In 75% of our simulated light curves, we measure the correct radius ratio; however, incorrect values can be measured if there is significant short-term variability in the light curve. Themore » maximum measured value of R{sub p}/R{sub ⋆} is 50% larger than the input value, which is much smaller than the large Lyα transit depths that have been reported in the literature, suggesting that for stars with activity levels comparable to the Sun, stellar activity alone cannot account for these deep transits. We ran simulations without a transit and found that stellar activity cannot mimic the Lyα transit of 55 Cancari b, strengthening the conclusion that this planet has a partially transiting exopshere. We were able to compare our simulations to more active stars by artificially increasing the variability in the Solar Lyα light curve. In the higher variability data, the largest value of R{sub p}/R{sub ⋆} we measured is <3× the input value, which again is not large enough to reproduce the Lyα transit depth reported for the more active stars HD 189733 and GJ 436, supporting the interpretation that these planets have extended atmospheres and possible cometary tails.« less

  5. Reporting of statistically significant results at ClinicalTrials.gov for completed superiority randomized controlled trials.

    PubMed

    Dechartres, Agnes; Bond, Elizabeth G; Scheer, Jordan; Riveros, Carolina; Atal, Ignacio; Ravaud, Philippe

    2016-11-30

    Publication bias and other reporting bias have been well documented for journal articles, but no study has evaluated the nature of results posted at ClinicalTrials.gov. We aimed to assess how many randomized controlled trials (RCTs) with results posted at ClinicalTrials.gov report statistically significant results and whether the proportion of trials with significant results differs when no treatment effect estimate or p-value is posted. We searched ClinicalTrials.gov in June 2015 for all studies with results posted. We included completed RCTs with a superiority hypothesis and considered results for the first primary outcome with results posted. For each trial, we assessed whether a treatment effect estimate and/or p-value was reported at ClinicalTrials.gov and if yes, whether results were statistically significant. If no treatment effect estimate or p-value was reported, we calculated the treatment effect and corresponding p-value using results per arm posted at ClinicalTrials.gov when sufficient data were reported. From the 17,536 studies with results posted at ClinicalTrials.gov, we identified 2823 completed phase 3 or 4 randomized trials with a superiority hypothesis. Of these, 1400 (50%) reported a treatment effect estimate and/or p-value. Results were statistically significant for 844 trials (60%), with a median p-value of 0.01 (Q1-Q3: 0.001-0.26). For the 1423 trials with no treatment effect estimate or p-value posted, we could calculate the treatment effect and corresponding p-value using results reported per arm for 929 (65%). For 494 trials (35%), p-values could not be calculated mainly because of insufficient reporting, censored data, or repeated measurements over time. For the 929 trials we could calculate p-values, we found statistically significant results for 342 (37%), with a median p-value of 0.19 (Q1-Q3: 0.005-0.59). Half of the trials with results posted at ClinicalTrials.gov reported a treatment effect estimate and/or p-value, with significant results for 60% of these. p-values could be calculated from results reported per arm at ClinicalTrials.gov for only 65% of the other trials. The proportion of significant results was much lower for these trials, which suggests a selective posting of treatment effect estimates and/or p-values when results are statistically significant.

  6. Assessment of PDMS-water partition coefficients: implications for passive environmental sampling of hydrophobic organic compounds

    USGS Publications Warehouse

    DiFilippo, Erica L.; Eganhouse, Robert P.

    2010-01-01

    Solid-phase microextraction (SPME) has shown potential as an in situ passive-sampling technique in aquatic environments. The reliability of this method depends upon accurate determination of the partition coefficient between the fiber coating and water (Kf). For some hydrophobic organic compounds (HOCs), Kf values spanning 4 orders of magnitude have been reported for polydimethylsiloxane (PDMS) and water. However, 24% of the published data examined in this review did not pass the criterion for negligible depletion, resulting in questionable Kf values. The range in reported Kf is reduced to just over 2 orders of magnitude for some polychlorinated biphenyls (PCBs) when these questionable values are removed. Other factors that could account for the range in reported Kf, such as fiber-coating thickness and fiber manufacturer, were evaluated and found to be insignificant. In addition to accurate measurement of Kf, an understanding of the impact of environmental variables, such as temperature and ionic strength, on partitioning is essential for application of laboratory-measured Kf values to field samples. To date, few studies have measured Kf for HOCs at conditions other than at 20 degrees or 25 degrees C in distilled water. The available data indicate measurable variations in Kf at different temperatures and different ionic strengths. Therefore, if the appropriate environmental variables are not taken into account, significant error will be introduced into calculated aqueous concentrations using this passive sampling technique. A multiparameter linear solvation energy relationship (LSER) was developed to estimate log Kf in distilled water at 25 degrees C based on published physicochemical parameters. This method provided a good correlation (R2 = 0.94) between measured and predicted log Kf values for several compound classes. Thus, an LSER approach may offer a reliable means of predicting log Kf for HOCs whose experimental log Kf values are presently unavailable. Future research should focus on understanding the impact of environmental variables on Kf. Obtaining the data needed for an LSER approach to estimate Kf for all environmentally relevant HOCs would be beneficial to the application of SPME as a passive-sampling technique.

  7. A measurement of the proton structure function F2( x, Q2) at low x and low Q2 at HERA

    NASA Astrophysics Data System (ADS)

    Adloff, C.; Aid, S.; Anderson, M.; Andreev, V.; Andrieu, B.; Arkadov, V.; Arndt, C.; Ayyaz, I.; Babaev, A.; Bähr, J.; Bán, J.; Ban, Y.; Baranov, P.; Barrelet, E.; Barschke, R.; Bartel, W.; Bassler, U.; Beck, H. P.; Beck, M.; Behrend, H.-J.; Belousov, A.; Berger, Ch.; Bernardi, G.; Bertrand-Coremans, G.; Beyer, R.; Biddulph, P.; Bispham, P.; Bizot, J. C.; Borras, K.; Botterweck, F.; Boudry, V.; Bourov, S.; Braemer, A.; Braunschweig, W.; Brisson, V.; Brückner, W.; Bruel, P.; Bruncko, D.; Brune, C.; Buchholz, R.; Büngener, L.; Bürger, J.; Büsser, F. W.; Buniatian, A.; Burke, S.; Burton, M. J.; Buschhorn, G.; Calvet, D.; Campbell, A. J.; Carli, T.; Charlet, M.; Clarke, D.; Clerbaux, B.; Cocks, S.; Contreras, J. G.; Cormack, C.; Coughlan, J. A.; Courau, A.; Cousinou, M.-C.; Cox, B. E.; Cozzika, G.; Cussans, D. G.; Cvach, J.; Dagoret, S.; Dainton, J. B.; Dau, W. D.; Daum, K.; David, M.; Davis, C. L.; De Roeck, A.; De Wolf, E. A.; Delcourt, B.; Dirkmann, M.; Dixon, P.; Dlugosz, W.; Dollfus, C.; Donovan, K. T.; Dowell, J. D.; Dreis, H. B.; Droutskoi, A.; Ebert, J.; Ebert, T. R.; Eckerlin, G.; Efremenko, V.; Egli, S.; Eichler, R.; Eisele, F.; Eisenhandler, E.; Elsen, E.; Erdmann, M.; Fahr, A. B.; Favart, L.; Fedotov, A.; Felst, R.; Feltesse, J.; Ferencei, J.; Ferrarotto, F.; Flamm, K.; Fleischer, M.; Flieser, M.; Flügge, G.; Fomenko, A.; Formánek, J.; Foster, J. M.; Franke, G.; Gabathuler, E.; Gabathuler, K.; Gaede, F.; Garvey, J.; Gayler, J.; Gebauer, M.; Genzel, H.; Gerhards, R.; Glazov, A.; Goerlich, L.; Gogitidze, N.; Goldberg, M.; Goldner, D.; Golec-Biernat, K.; Gonzalez-Pineiro, B.; Gorelov, I.; Grab, C.; Grässler, H.; Greenshaw, T.; Griffiths, R. K.; Grindhammer, G.; Gruber, A.; Gruber, C.; Hadig, T.; Haidt, D.; Hajduk, L.; Haller, T.; Hampel, M.; Haynes, W. J.; Heinemann, B.; Heinzelmann, G.; Henderson, R. C. W.; Henschel, H.; Herynek, I.; Hess, M. F.; Hewitt, K.; Hiller, K. H.; Hilton, C. D.; Hladký, J.; Höppner, M.; Hoffmann, D.; Holtom, T.; Horisberger, R.; Hudgson, V. L.; Hütte, M.; Ibbotson, M.; İşsever, Ç.; Itterbeck, H.; Jacholkowska, A.; Jacobsson, C.; Jacquet, M.; Jaffre, M.; Janoth, J.; Jansen, D. M.; Jönsson, L.; Johnson, D. P.; Jung, H.; Kalmus, P. I. P.; Kander, M.; Kant, D.; Kathage, U.; Katzy, J.; Kaufmann, H. H.; Kaufmann, O.; Kausch, M.; Kazarian, S.; Kenyon, I. R.; Kermiche, S.; Keuker, C.; Kiesling, C.; Klein, M.; Kleinwort, C.; Knies, G.; Köhler, T.; Köhne, J. H.; Kolanoski, H.; Kolya, S. D.; Korbel, V.; Kostka, P.; Kotelnikov, S. K.; Krämerkämper, T.; Krasny, M. W.; Krehbiel, H.; Krücker, D.; Küpper, A.; Küster, H.; Kuhlen, M.; Kurča, T.; Kurzhöfer, J.; Laforge, B.; Landon, M. P. J.; Lange, W.; Langenegger, U.; Lebedev, A.; Lehner, F.; Lemaitre, V.; Levonian, S.; Lindstroem, M.; Linsel, F.; Lipinski, J.; List, B.; Lobo, G.; Lomas, J. W.; Lopez, G. C.; Lubimov, V.; Lüke, D.; Lytkin, L.; Magnussen, N.; Mahlke-Krüger, H.; Malinovski, E.; Maraček, R.; Marage, P.; Marks, J.; Marshall, R.; Martens, J.; Martin, G.; Martin, R.; Martyn, H.-U.; Martyniak, J.; Mavroidis, T.; Maxfield, S. J.; McMahon, S. J.; Mehta, A.; Meier, K.; Merkel, P.; Metlica, F.; Meyer, A.; Meyer, A.; Meyer, H.; Meyer, J.; Meyer, P.-O.; Migliori, A.; Mikocki, S.; Milstead, D.; Moeck, J.; Moreau, F.; Morris, J. V.; Mroczko, E.; Müller, D.; Walter, T.; Müller, K.; Murín, P.; Nagovizin, V.; Nahnhauer, R.; Naroska, B.; Naumann, Th.; Négri, I.; Newman, P. R.; Newton, D.; Nguyen, H. K.; Nicholls, T. C.; Niebergall, F.; Niebuhr, C.; Niedzballa, Ch.; Niggli, H.; Nowak, G.; Nunnemann, T.; Nyberg-Werther, M.; Oberlack, H.; Olsson, J. E.; Ozerov, D.; Palmen, P.; Panaro, E.; Panitch, A.; Pascaud, C.; Passaggio, S.; Patel, G. D.; Pawletta, H.; Peppel, E.; Perez, E.; Phillips, J. P.; Pieuchot, A.; Pitzl, D.; Pöschl, R.; Pope, G.; Povh, B.; Prell, S.; Rabbertz, K.; Rädel, G.; Reimer, P.; Rick, H.; Riess, S.; Rizvi, E.; Robmann, P.; Roosen, R.; Rosenbauer, K.; Rostovtsev, A.; Rouse, F.; Royon, C.; Rüter, K.; Rusakov, S.; Rybicki, K.; Sankey, D. P. C.; Schacht, P.; Schiek, S.; Schleif, S.; Schleper, P.; von Schlippe, W.; Schmidt, D.; Schmidt, G.; Schoeffel, L.; Schöning, A.; Schröder, V.; Schuhmann, E.; Schwab, B.; Sefkow, F.; Semenov, A.; Shekelyan, V.; Sheviakov, I.; Shtarkov, L. N.; Siegmon, G.; Siewert, U.; Sirois, Y.; Skillicorn, I. O.; Sloan, T.; Smirnov, P.; Smith, M.; Solochenko, V.; Soloviev, Y.; Specka, A.; Spiekermann, J.; Spielman, S.; Spitzer, H.; Squinabol, F.; Steffen, P.; Steinberg, R.; Steinhart, J.; Stella, B.; Stellberger, A.; Stier, J.; Stiewe, J.; Stöβlein, U.; Stolze, K.; Straumann, U.; Struczinski, W.; Sutton, J. P.; Tapprogge, S.; Taševský, M.; Tchernyshov, V.; Tchetchelnitski, S.; Theissen, J.; Thompson, G.; Thompson, P. D.; Tobien, N.; Todenhagen, R.; Truöl, P.; Tsipolitis, G.; Turnau, J.; Tzamariudaki, E.; Uelkes, P.; Usik, A.; Valkár, S.; Valkárová, A.; Valĺee, C.; Van Esch, P.; Van Mechelen, P.; Vandenplas, D.; Vazdik, Y.; Verrecchia, P.; Villet, G.; Wacker, K.; Wagener, A.; Wagener, M.; Wallny, R.; Waugh, B.; Weber, G.; Weber, M.; Wegener, D.; Wegner, A.; Wengler, T.; Werner, M.; West, L. R.; Wiesand, S.; Wilksen, T.; Willard, S.; Winde, M.; Winter, G.-G.; Wittek, C.; Wobisch, M.; Wollatz, H.; Wünsch, E.; Žáček, J.; Zarbock, D.; Zhang, Z.; Zhokin, A.; Zini, P.; Zomer, F.; Zsembery, J.; zurNedden, M.; H1 Collaboration

    1997-02-01

    The results of a measurement of the proton structure function F2( x, Q2) and the virtual photon-proton cross section are reported for momentum transfers squared Q2 between 0.35 GeV 2 and 3.5 GeV 2 and for Bjorken- x values down to 6 × 10 -6 using data collected by the HERA experiment H1 in 1995. The data represent an increase in kinematic reach to lower x and Q2 values of about a factor of 5 compared to previous H1 measurements. Including measurements from fixed target experiments the rise of F2 with decreasing x is found to be less steep for the lowest Q2 values measured. Phenomenological models at low Q2 are compared with the data.

  8. Ventilation-perfusion distribution in normal subjects.

    PubMed

    Beck, Kenneth C; Johnson, Bruce D; Olson, Thomas P; Wilson, Theodore A

    2012-09-01

    Functional values of LogSD of the ventilation distribution (σ(V)) have been reported previously, but functional values of LogSD of the perfusion distribution (σ(q)) and the coefficient of correlation between ventilation and perfusion (ρ) have not been measured in humans. Here, we report values for σ(V), σ(q), and ρ obtained from wash-in data for three gases, helium and two soluble gases, acetylene and dimethyl ether. Normal subjects inspired gas containing the test gases, and the concentrations of the gases at end-expiration during the first 10 breaths were measured with the subjects at rest and at increasing levels of exercise. The regional distribution of ventilation and perfusion was described by a bivariate log-normal distribution with parameters σ(V), σ(q), and ρ, and these parameters were evaluated by matching the values of expired gas concentrations calculated for this distribution to the measured values. Values of cardiac output and LogSD ventilation/perfusion (Va/Q) were obtained. At rest, σ(q) is high (1.08 ± 0.12). With the onset of ventilation, σ(q) decreases to 0.85 ± 0.09 but remains higher than σ(V) (0.43 ± 0.09) at all exercise levels. Rho increases to 0.87 ± 0.07, and the value of LogSD Va/Q for light and moderate exercise is primarily the result of the difference between the magnitudes of σ(q) and σ(V). With known values for the parameters, the bivariate distribution describes the comprehensive distribution of ventilation and perfusion that underlies the distribution of the Va/Q ratio.

  9. Redefining Quality Measurement in Cancer Care.

    PubMed

    Nardi, Elizabeth A; McCanney, James; Winckworth-Prejsnar, Katy; Schatz, Alyssa A; Adelson, Kerin; Neubauer, Marcus; Smith, Mary Lou; Walters, Ronald; Carlson, Robert W

    2018-05-01

    Quality measurement in oncology is increasing in significance as payment schemes shift from volume to value. As demand for quality measures increases, challenges in the development of quality measures, standardization across measures, and the limitations of health information technology have become apparent. Moreover, the time and financial burden associated with developing, tracking, and reporting quality measures are substantial. Despite these challenges, best practices and leaders in the field of quality measurement in oncology have emerged. To understand the current challenges and promising practices in quality measurement and to explore future considerations for measure development and measure reporting in oncology, NCCN convened the NCCN Policy Summit: Redefining Quality Measurement in Oncology. The summit included discussion of the current quality landscape and efforts to develop quality measures, use of quality measures in various programs, patient perspective of quality, and challenges and best practices for quality reporting. Copyright © 2018 by the National Comprehensive Cancer Network.

  10. Water quality of the tidal Potomac River and Estuary; hydrologic data report supplement, 1979 through 1981 water years

    USGS Publications Warehouse

    Coupe, R.H.; Webb, W.E.

    1984-01-01

    This report is a companion report to the U.S. Geological Survey 1979, 1980, and 1981 Hydrologic Data Reports of the tidal Potomac River and Estuary. It contains values of biochemical oxygen demand and specific rate constants, incident light and light attenuation measurements; numbers of phytoplankton, fecal coliform and fecal streptococci, cross-sectional averages from field measurements of dissolved oxygen, pH, specific conductance , and temperature data; and cross-sectional averages of chlorophyll data. Sewage treatment plant loads are also included. (USGS)

  11. Automated extraction of ejection fraction for quality measurement using regular expressions in Unstructured Information Management Architecture (UIMA) for heart failure.

    PubMed

    Garvin, Jennifer H; DuVall, Scott L; South, Brett R; Bray, Bruce E; Bolton, Daniel; Heavirland, Julia; Pickard, Steve; Heidenreich, Paul; Shen, Shuying; Weir, Charlene; Samore, Matthew; Goldstein, Mary K

    2012-01-01

    Left ventricular ejection fraction (EF) is a key component of heart failure quality measures used within the Department of Veteran Affairs (VA). Our goals were to build a natural language processing system to extract the EF from free-text echocardiogram reports to automate measurement reporting and to validate the accuracy of the system using a comparison reference standard developed through human review. This project was a Translational Use Case Project within the VA Consortium for Healthcare Informatics. We created a set of regular expressions and rules to capture the EF using a random sample of 765 echocardiograms from seven VA medical centers. The documents were randomly assigned to two sets: a set of 275 used for training and a second set of 490 used for testing and validation. To establish the reference standard, two independent reviewers annotated all documents in both sets; a third reviewer adjudicated disagreements. System test results for document-level classification of EF of <40% had a sensitivity (recall) of 98.41%, a specificity of 100%, a positive predictive value (precision) of 100%, and an F measure of 99.2%. System test results at the concept level had a sensitivity of 88.9% (95% CI 87.7% to 90.0%), a positive predictive value of 95% (95% CI 94.2% to 95.9%), and an F measure of 91.9% (95% CI 91.2% to 92.7%). An EF value of <40% can be accurately identified in VA echocardiogram reports. An automated information extraction system can be used to accurately extract EF for quality measurement.

  12. Water quality of the tidal Potomac River and Estuary: Hydrologic Data Reports supplement, 1979 through 1981 water years

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coupe, R.H. Jr.; Webb, W.E.

    1984-01-01

    This report is a companion report to the US Geological Survey 1979, 1980, and 1981 Hydrologic Data Reports of the tidal Potomac River and Estuary. The information included in this report contains values of biochemical oxygen demand and specific-rate constants, incident-light and light-attenuation measurements; numbers of phytoplankton, fecal coliform and fecal streptococci; cross-sectional averages from field measurements of dissolved oxygen, pH, specific conductance, and temperature data; and cross-sectional averages of chlorophyll data. Sewage-treatment plant loads are also included. 29 refs., 4 figs., 3 tabs.

  13. Gradient of the stellar magnetic field in measurements of hydrogen line cores

    NASA Astrophysics Data System (ADS)

    Kudryavtsev, Dimitry O.; Romanyuk, Iosif I.

    2009-04-01

    We report the observed systematic differences in longitudinal magnetic field values, obtained from measurements of metal lines and the core of the Hβ line for a number of Ap stars, having strong global magnetic fields. In overwhelming majority of cases the magnetic field values, obtained from measurements of hydrogen lines cores, is smaller then the ones obtained from metal lines. We discuss some possible explanations of this effect, the most probable of which is the existence of the gradient of the magnetic field in stellar atmospheres.

  14. Physical Activity Assessment Between Consumer- and Research-Grade Accelerometers: A Comparative Study in Free-Living Conditions.

    PubMed

    Dominick, Gregory M; Winfree, Kyle N; Pohlig, Ryan T; Papas, Mia A

    2016-09-19

    Wearable activity monitors such as Fitbit enable users to track various attributes of their physical activity (PA) over time and have the potential to be used in research to promote and measure PA behavior. However, the measurement accuracy of Fitbit in absolute free-living conditions is largely unknown. To examine the measurement congruence between Fitbit Flex and ActiGraph GT3X for quantifying steps, metabolic equivalent tasks (METs), and proportion of time in sedentary activity and light-, moderate-, and vigorous-intensity PA in healthy adults in free-living conditions. A convenience sample of 19 participants (4 men and 15 women), aged 18-37 years, concurrently wore the Fitbit Flex (wrist) and ActiGraph GT3X (waist) for 1- or 2-week observation periods (n=3 and n=16, respectively) that included self-reported bouts of daily exercise. Data were examined for daily activity, averaged over 14 days and for minutes of reported exercise. Average day-level data included steps, METs, and proportion of time in different intensity levels. Minute-level data included steps, METs, and mean intensity score (0 = sedentary, 3 = vigorous) for overall reported exercise bouts (N=120) and by exercise type (walking, n=16; run or sports, n=44; cardio machine, n=20). Measures of steps were similar between devices for average day- and minute-level observations (all P values > .05). Fitbit significantly overestimated METs for average daily activity, for overall minutes of reported exercise bouts, and for walking and run or sports exercises (mean difference 0.70, 1.80, 3.16, and 2.00 METs, respectively; all P values < .001). For average daily activity, Fitbit significantly underestimated the proportion of time in sedentary and light intensity by 20% and 34%, respectively, and overestimated time by 3% in both moderate and vigorous intensity (all P values < .001). Mean intensity scores were not different for overall minutes of exercise or for run or sports and cardio-machine exercises (all P values > .05). Fitbit Flex provides accurate measures of steps for daily activity and minutes of reported exercise, regardless of exercise type. Although the proportion of time in different intensity levels varied between devices, examining the mean intensity score for minute-level bouts across different exercise types enabled interdevice comparisons that revealed similar measures of exercise intensity. Fitbit Flex is shown to have measurement limitations that may affect its potential utility and validity for measuring PA attributes in free-living conditions.

  15. Measurement of elasticity and transepidermal water loss rate of burn scars with the Dermalab(®).

    PubMed

    Anthonissen, Mieke; Daly, Daniel; Fieuws, Steffen; Massagé, Patrick; Van Brussel, Michel; Vranckx, Jan; Van den Kerckhove, Eric

    2013-05-01

    This cross-sectional study investigated the reproducibility of repeated elasticity and transepidermal water loss (TEWL) measurements with the DermaLab(®) on 32 active burn scars and healthy skin. Intra- and inter-observer reproducibility was examined by means of intra-class correlation coefficients (ICC) and standard error of measurements (SEM). Results showed good ICC values and rather high SEM values for inter- and intra-observer reproducibility of elasticity measurements. For TEWL measurements, ICC values were good and SEM values were high for inter- and intra-observer reproducibility. There was a significant difference between the estimated mean elasticity values of normal skin and grafted scars and between normal skin and spontaneously healed scars (p≤0.003). For the estimated mean TEWL values, there was a significant difference between normal skin and spontaneously healed scars (p=0.036). A significant negative relation was reported between mean TEWL and time after burn (p=0.008). In clinical trials it is necessary to interpret patient-specific changes in elasticity and TEWL with caution, since the SEMs of both modes are rather high. We therefore recommend the use of a mean of repeated measurements of elasticity and TEWL to decrease the SEM. Copyright © 2012 Elsevier Ltd and ISBI. All rights reserved.

  16. A Century of Grading Research: Meaning and Value in the Most Common Educational Measure

    ERIC Educational Resources Information Center

    Brookhart, Susan M.; Guskey, Thomas R.; Bowers, Alex J.; McMillan, James H.; Smith, Jeffrey K.; Smith, Lisa F.; Stevens, Michael T.; Welsh, Megan E.

    2016-01-01

    Grading refers to the symbols assigned to individual pieces of student work or to composite measures of student performance on report cards. This review of over 100 years of research on grading considers five types of studies: (a) early studies of the reliability of grades, (b) quantitative studies of the composition of K-12 report card grades,…

  17. How accurate are self-reported height, weight, and BMI among community-dwelling elderly Japanese?: Evidence from a national population-based study.

    PubMed

    Yong, Vanessa; Saito, Yasuhiko

    2012-04-01

    The aims of this study are to investigate the accuracy of self-reported height, weight, and derived BMI of community-dwelling Japanese aged 70 and older, and to assess the concordance between report-based and measurement-based BMI categories. We compared self-reported height and weight with physical measurements from data from a nationally representative sample (n = 1634). Self-reported values were strongly correlated with measured values (Pearson's r: 0.92 and 0.89 for men and women, respectively, for height; 0.96 for both sexes for weight; 0.93 and 0.91 for men and women, respectively, for BMI). The differences in mean values were small. On average, height was overreported by 0.93 cm (SD = 2.48) for men and 1.23 cm (SD = 2.84) for women. Weight was underreported by 1.08 kg (SD = 2.55) for men and 0.88 kg (SD = 2.45) for women. BMI was underestimated by 0.68 kg/m(2) (SD = 1.16) for men and 0.79 kg/m(2) (SD = 1.49) for women. As age increases, height overreporting increased, particularly among women, but weight underreporting decreased for women. BMI underestimation increased for both sexes. Weighted kappa values showed a reasonably high concordance at 0.715 and 0.670 for men and women, respectively (P < 0.0001). Overweight (BMI 25.0 to 29.9) and obesity (BMI ≥ 30) prevalence rates were underestimated, with better specificity (range: 94.4-100%) than sensitivity (range: 59.3-65.1%). The accuracy of self-reported height and weight is reasonably high among elderly Japanese, suggesting that the information can be used in epidemiological surveys. However, caution should be exercised for the oldest age group (age 85+), as the accuracy declined. © 2011 Japan Geriatrics Society.

  18. Determination of Henry`s law constants by equilibrium partitioning in a closed system using a new in situ optical absorbance method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allen, J.M.; Balcavage, W.X.; Ramachandran, B.R.

    Currently, a great deal of interest exists in developing quantitative descriptions of the transport behavior for organic chemical compounds in the environment. Transport between water and air is of particular significance in this regard. A new method for measurement of thermodynamic Henry`s law constants (H) is reported. In this method, the optical absorbance of a dilute aqueous solution containing an organic compound is followed with time as the compound partitions into the air above the solution in a sealed vessel. The change in optical absorbance and the vapor to liquid volume ratio of the vessel are then used to calculatemore » the value for H. The concentration of the organic compound in the aqueous and vapor phases need not be known. This method allows the approach to equilibrium to be observed in real time so that attainment of equilibrium is readily apparent. This method works particularly well for water-soluble compounds having low vapor pressures. The applicability of this method is limited to compounds that exhibit significant optical absorbance in the ultraviolet and visible regions of the electromagnetic spectrum. Values for H and their temperature dependencies measured using this new method are reported for methacrolein, methyl vinyl ketone, benzaldehyde, and acetophenone. Values for H are also reported for benzene, toluene, and ethylbenzene at 298 K. All reported H data are compared with previously reported values.« less

  19. Validity of self-reported height and weight in 4808 EPIC-Oxford participants.

    PubMed

    Spencer, Elizabeth A; Appleby, Paul N; Davey, Gwyneth K; Key, Timothy J

    2002-08-01

    To assess the validity of self-reported height and weight by comparison with measured height and weight in a sample of middle-aged men and women, and to determine the extent of misclassification of body mass index (BMI) arising from differences between self-reported and measured values. Analysis of self-reported and measured height and weight data from participants in the Oxford cohort of the European Prospective Investigation into Cancer and Nutrition (EPIC-Oxford). Four thousand eight hundred and eight British men and women aged 35-76 years. Spearman rank correlations between self-reported and measured height, weight and BMI were high (r > 0.9, P < 0.0001). Height was overestimated by a mean of 1.23 (95% confidence interval (CI) 1.11-1.34) cm in men and 0.60 (0.51-0.70) cm in women; the extent of overestimation was greater in older men and women, shorter men and heavier women. Weight was underestimated by a mean of 1.85 (1.72-1.99) kg in men and 1.40 (1.31-1.49) kg in women; the extent of underestimation was greater in heavier men and women, but did not vary with age or height. Using standard categories of BMI, 22.4% of men and 18.0% of women were classified incorrectly based on self-reported height and weight. After correcting the self-reported values using predictive equations derived from a 10% sample of subjects, misclassification decreased to 15.2% in men and 13.8% in women. Self-reported height and weight data are valid for identifying relationships in epidemiological studies. In analyses where anthropometric factors are the primary variables of interest, measurements in a representative sample of the study population can be used to improve the accuracy of estimates of height, weight and BMI.

  20. Recommendations for newborn screening for galactokinase deficiency: A systematic review and evaluation of Dutch newborn screening data.

    PubMed

    Stroek, Kevin; Bouva, Marelle J; Schielen, Peter C J I; Vaz, Frédéric M; Heijboer, Annemieke C; de Jonge, Robert; Boelen, Anita; Bosch, Annet M

    2018-03-21

    Galactokinase (GALK) deficiency causes cataract leading to severe developmental consequences unless treated early. Because of the easy prevention and rapid reversibility of cataract with treatment, the Dutch Health Council advised to include GALK deficiency in the Dutch newborn screening program. The aim of this study is to establish the optimal screening method and cut-off value (COV) for GALK deficiency screening by performing a systematic review of the literature of screening strategies and total galactose (TGAL) values and by evaluating TGAL values in the first week of life in a cohort of screened newborns in the Netherlands. Systematic literature search strategies in OVID MEDLINE and OVID EMBASE were developed and study selection, data collection and analyses were performed by two independent investigators. A range of TGAL values measured by the Quantase Neonatal Total Galactose screening assay in a cohort of Dutch newborns in 2007 was evaluated. Eight publications were included in the systematic review. All four studies describing screening strategies used TGAL as the primary screening marker combined with galactose-1-phosphate uridyltransferase (GALT) measurement that is used for classical galactosemia screening. TGAL COVs of 2200 μmol/L, 1665 μmol/L and 1110 μmol/L blood resulted in positive predictive values (PPV) of 100%, 82% and 10% respectively. TGAL values measured in the newborn period were reported for 39 GALK deficiency patients with individual values ranging from 3963 to 8159 μmol/L blood and 2 group values with mean 8892 μmol/L blood (SD ± 5243) and 4856 μmol/L blood (SD ± 461). Dutch newborn screening data of 72,786 newborns from 2007 provided a median TGAL value of 110 μmol/L blood with a range of 30-2431 μmol/L blood. Based on TGAL values measured in GALK deficiency patients reported in the literature and TGAL measurements in the Dutch cohort by newborn screening we suggest to perform the GALK screening with TGAL as a primary marker with a COV of 2500 μmol/L blood, combined with GALT enzyme activity measurement as used in the classical galactosemia screening, to ensure detection of GALK deficiency patients and minimize false positive referrals. Copyright © 2018. Published by Elsevier Inc.

  1. Probing Planck's Law at Home

    ERIC Educational Resources Information Center

    Bonnet, I.; Gabelli, J.

    2010-01-01

    We report on the physics around an incandescent lamp. Using a consumer-grade digital camera, we combine electrical and optical measurements to explore Planck's law of black-body radiation. This simple teaching experiment is successfully used to measure both Stefan's and Planck's constants. Our measurements lead to a strikingly accurate value for…

  2. A Comparison of Three Methods to Measure Percent Body Fat on Mentally Retarded Adults.

    ERIC Educational Resources Information Center

    Burkett, Lee N.; And Others

    1994-01-01

    Reports a study that compared three measures for determining percent body fat in mentally retarded adults (multiple skinfolds and circumference measurements, Infrared Interactance, and Bioelectrical Impedance). Results indicated the Bioelectrical Impedance Analyzer and Infrared Interactance Analyzer produced values for percent body fat that were…

  3. Reporting and methodological quality of sample size calculations in cluster randomized trials could be improved: a review.

    PubMed

    Rutterford, Clare; Taljaard, Monica; Dixon, Stephanie; Copas, Andrew; Eldridge, Sandra

    2015-06-01

    To assess the quality of reporting and accuracy of a priori estimates used in sample size calculations for cluster randomized trials (CRTs). We reviewed 300 CRTs published between 2000 and 2008. The prevalence of reporting sample size elements from the 2004 CONSORT recommendations was evaluated and a priori estimates compared with those observed in the trial. Of the 300 trials, 166 (55%) reported a sample size calculation. Only 36 of 166 (22%) reported all recommended descriptive elements. Elements specific to CRTs were the worst reported: a measure of within-cluster correlation was specified in only 58 of 166 (35%). Only 18 of 166 articles (11%) reported both a priori and observed within-cluster correlation values. Except in two cases, observed within-cluster correlation values were either close to or less than a priori values. Even with the CONSORT extension for cluster randomization, the reporting of sample size elements specific to these trials remains below that necessary for transparent reporting. Journal editors and peer reviewers should implement stricter requirements for authors to follow CONSORT recommendations. Authors should report observed and a priori within-cluster correlation values to enable comparisons between these over a wider range of trials. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  4. Addressing Current Criticism Regarding the Value of Self-Report Dietary Data.

    PubMed

    Subar, Amy F; Freedman, Laurence S; Tooze, Janet A; Kirkpatrick, Sharon I; Boushey, Carol; Neuhouser, Marian L; Thompson, Frances E; Potischman, Nancy; Guenther, Patricia M; Tarasuk, Valerie; Reedy, Jill; Krebs-Smith, Susan M

    2015-12-01

    Recent reports have asserted that, because of energy underreporting, dietary self-report data suffer from measurement error so great that findings that rely on them are of no value. This commentary considers the amassed evidence that shows that self-report dietary intake data can successfully be used to inform dietary guidance and public health policy. Topics discussed include what is known and what can be done about the measurement error inherent in data collected by using self-report dietary assessment instruments and the extent and magnitude of underreporting energy compared with other nutrients and food groups. Also discussed is the overall impact of energy underreporting on dietary surveillance and nutritional epidemiology. In conclusion, 7 specific recommendations for collecting, analyzing, and interpreting self-report dietary data are provided: (1) continue to collect self-report dietary intake data because they contain valuable, rich, and critical information about foods and beverages consumed by populations that can be used to inform nutrition policy and assess diet-disease associations; (2) do not use self-reported energy intake as a measure of true energy intake; (3) do use self-reported energy intake for energy adjustment of other self-reported dietary constituents to improve risk estimation in studies of diet-health associations; (4) acknowledge the limitations of self-report dietary data and analyze and interpret them appropriately; (5) design studies and conduct analyses that allow adjustment for measurement error; (6) design new epidemiologic studies to collect dietary data from both short-term (recalls or food records) and long-term (food-frequency questionnaires) instruments on the entire study population to allow for maximizing the strengths of each instrument; and (7) continue to develop, evaluate, and further expand methods of dietary assessment, including dietary biomarkers and methods using new technologies. © 2015 American Society for Nutrition.

  5. A Framework for Measuring the Economic Benefits of Ground Water (1995)

    EPA Pesticide Factsheets

    The primary goal of this 1995 report is to develop a framework for assessing the economic value of ground water that is applicable to all offices within U.S. EPA that consider the value of ground water resources when conducting Regulatory Impact Analyses

  6. Unlocking echocardiogram measurements for heart disease research through natural language processing.

    PubMed

    Patterson, Olga V; Freiberg, Matthew S; Skanderson, Melissa; J Fodeh, Samah; Brandt, Cynthia A; DuVall, Scott L

    2017-06-12

    In order to investigate the mechanisms of cardiovascular disease in HIV infected and uninfected patients, an analysis of echocardiogram reports is required for a large longitudinal multi-center study. A natural language processing system using a dictionary lookup, rules, and patterns was developed to extract heart function measurements that are typically recorded in echocardiogram reports as measurement-value pairs. Curated semantic bootstrapping was used to create a custom dictionary that extends existing terminologies based on terms that actually appear in the medical record. A novel disambiguation method based on semantic constraints was created to identify and discard erroneous alternative definitions of the measurement terms. The system was built utilizing a scalable framework, making it available for processing large datasets. The system was developed for and validated on notes from three sources: general clinic notes, echocardiogram reports, and radiology reports. The system achieved F-scores of 0.872, 0.844, and 0.877 with precision of 0.936, 0.982, and 0.969 for each dataset respectively averaged across all extracted values. Left ventricular ejection fraction (LVEF) is the most frequently extracted measurement. The precision of extraction of the LVEF measure ranged from 0.968 to 1.0 across different document types. This system illustrates the feasibility and effectiveness of a large-scale information extraction on clinical data. New clinical questions can be addressed in the domain of heart failure using retrospective clinical data analysis because key heart function measurements can be successfully extracted using natural language processing.

  7. Use of self-reported measures of height, weight and body mass index in a rural population of Northeast Brazil.

    PubMed

    Martins, Poliana Cardoso; de Carvalho, Maria Bernadete; Machado, Carla Jorge

    2015-01-01

    To assess the validity of using self-reported anthropometric data for diagnosis of nutritional status of adults in a rural population of northeast Brazil. A population-based survey was conducted on a sample of 797 individuals aged 18 years or more. The proportion of individuals who knew their anthropometric measures was calculated. For agreement analysis between those who reported their measures the following indicators were obtained: differences between averages (weight, height, body mass index), intra-class correlation coefficient (ICC), Kappa statistic, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (VPN). Bland-Altman graphics were also obtained. More than half of the respondents (58.5%) did not know their weight or height. Weight was the most known measure among all. The magnitude of the mean difference for weight, height and body mass index (BMI) (0.43 kg, 0.31 cm, 0.32 kg/m2, respectively) was small, indicating good agreement, with a trend toward overestimation. ICC for weight, height and BMI were 0.96; 0.60; and 0.53, respectively. Kappa statistic indicated good agreement in all strata. General measures of sensitivity, specificity, PPV and NPV were 84.2; 82; 90.7 and 71.3%, respectively. Elderly, those with low schooling and those who do not often weigh were less accurate on their measures. The use of self-reported measures should be done with caution in epidemiological studies in rural populations.

  8. Colorimetric values of esthetic stainless steel crowns.

    PubMed

    Hosoya, Yumiko; Omachi, Koichi; Staninec, Michal

    2002-01-01

    The colorimetric values of two different kinds of esthetic stainless steel crowns were measured and compared with the colorimetric values of primary anterior teeth in Japanese children. The colorimetric values of resin composite-faced stainless steel crowns (Kinder Krown) and epoxy-coated stainless steel crowns (White Steel Crown) were measured with a color difference meter. The Commission Internationale de Eclairage L*, a*, b*, and delta E*ab values and Munsell value, chroma, and hue were calculated. The data were compared with previously reported colorimetric values of Japanese primary anterior teeth measured with the same color difference meter used in this study. Compared to Japanese primary anterior teeth, Kinder Krown Pedo I and Pedo II showed much higher L* values and lower hue; on the other hand, White Steel Crown showed much higher L*, a*, b* values, much higher value and chroma, and much lower hue. Color analysis revealed that the colors of the White Steel Crown and Kinder Krown Pedo I were substantially different from the color of Japanese primary anterior teeth. The color difference between Pedo II crowns and Japanese primary anterior teeth was relatively high, but the color of Pedo II might be acceptable for clinical use.

  9. Measurement of the cleavage energy of graphite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Wen; Dai, Shuyang; Li, Xide

    Here, the basal plane cleavage energy (CE) of graphite is a key material parameter for understanding many of the unusual properties of graphite, graphene and carbon nanotubes. Nonetheless, a wide range of values for the CE has been reported and no consensus has yet emerged. Here we report the first direct, accurate experimental measurement of the CE of graphite using a novel method based on the self-retraction phenomenon in graphite. The measured value, 0.37±0.01 J m –2 for the incommensurate state of bicrystal graphite, is nearly invariant with respect to temperature (22 °C≤T≤198 °C) and bicrystal twist angle, and insensitivemore » to impurities from the atmosphere. The CE for the ideal ABAB graphite stacking, 0.39±0.02 J m –2, is calculated based on a combination of the measured CE and a theoretical calculation. These experimental measurements are also ideal for use in evaluating the efficacy of competing theoretical approaches.« less

  10. Measurement of the cleavage energy of graphite

    DOE PAGES

    Wang, Wen; Dai, Shuyang; Li, Xide; ...

    2015-08-28

    Here, the basal plane cleavage energy (CE) of graphite is a key material parameter for understanding many of the unusual properties of graphite, graphene and carbon nanotubes. Nonetheless, a wide range of values for the CE has been reported and no consensus has yet emerged. Here we report the first direct, accurate experimental measurement of the CE of graphite using a novel method based on the self-retraction phenomenon in graphite. The measured value, 0.37±0.01 J m –2 for the incommensurate state of bicrystal graphite, is nearly invariant with respect to temperature (22 °C≤T≤198 °C) and bicrystal twist angle, and insensitivemore » to impurities from the atmosphere. The CE for the ideal ABAB graphite stacking, 0.39±0.02 J m –2, is calculated based on a combination of the measured CE and a theoretical calculation. These experimental measurements are also ideal for use in evaluating the efficacy of competing theoretical approaches.« less

  11. M sub shell X-ray emission cross section measurements for Pt, Au, Hg, Pb, Th and U at 8 and 10 keV synchrotron photons

    NASA Astrophysics Data System (ADS)

    Kaur, Gurpreet; Gupta, Sheenu; Tiwari, M. K.; Mittal, Raj

    2014-02-01

    M sub shell X-ray emission cross sections of Pt, Au, Hg, Pb, Th and U at 8 and 10 keV photon energies have been determined with linearly polarized photon beam from Indus-2 synchrotron source. The measured cross sections have been reported for the first time and were used to check the available theoretical Dirac-Hartree-Slater (DHS) and Dirac-Fock (DF) values reported in literature and also the presently derived Non Relativistic Hartree-Slater (NRHS), DF and DHS values for Mξ, Mδ, Mα, Mβ, Mγ, Mm1 and Mm2 group of X-rays.

  12. Measuring Individual Performance with Comprehensive Bibliometric Reports as an Alternative to h-Index Values

    PubMed Central

    2018-01-01

    The h-index is frequently used to measure the performance of single scientists in Korea (and beyond). No single indicator alone, however, is able to provide a stable and complete assessment of performance. The Stata command bibrep.ado is introduced which automatically produces bibliometric reports for single researchers (senior researchers working in the natural or life sciences). The user of the command receives a comprehensive bibliometric report which can be used in research evaluation instead of the h-index. PMID:29713257

  13. ACTRIS non-methane hydrocarbon intercomparison experiment in Europe to support WMO-GAW and EMEP observation networks

    NASA Astrophysics Data System (ADS)

    Hoerger, C. C.; Werner, A.; Plass-Duelmer, C.; Reimann, S.; Eckart, E.; Steinbrecher, R.; Aalto, J.; Arduini, J.; Bonnaire, N.; Cape, J. N.; Colomb, A.; Connolly, R.; Diskova, J.; Dumitrean, P.; Ehlers, C.; Gros, V.; Hakola, H.; Hill, M.; Hopkins, J. R.; Jäger, J.; Junek, R.; Kajos, M. K.; Klemp, D.; Leuchner, M.; Lewis, A. C.; Locoge, N.; Maione, M.; Martin, D.; Michl, K.; Nemitz, E.; O'Doherty, S.; Pérez Ballesta, P.; Ruuskanen, T. M.; Sauvage, S.; Schmidbauer, N.; Spain, T. G.; Straube, E.; Vana, M.; Vollmer, M. K.; Wegener, R.; Wenger, A.

    2014-10-01

    The performance of 20 European laboratories involved in long-term non-methane hydrocarbon (NMHC) measurements within the framework of Global Atmosphere Watch (GAW) and European Monitoring and Evaluation Programme (EMEP) was assessed with respect to the ACTRIS (Aerosols, Clouds, and Trace gases Research InfraStructure Network) and GAW data quality objectives (DQOs). Compared to previous intercomparisons the DQOs of ACTRIS are much more demanding with deviations to a reference value of less than 5% and repeatability of better than 2% for mole fractions above 0.1 nmol mol-1. The participants were asked to measure both a 30 component NMHC mixture in nitrogen (NMHC_N2) at approximately 1 nmol mol-1 and whole air (NMHC_air), following a standardised operation procedure including zero- and calibration gas measurements. Furthermore, they had to report details on their instruments and they were asked to assess measurement uncertainties. The NMHCs were analysed either by gas chromatography-flame ionisation detection or gas chromatography-mass spectrometer methods. Most systems performed well for the NMHC_N2 measurements (88% of the reported values were within the GAW DQOs and even 58% within the ACTRIS DQOs). For NMHC_air generally more frequent and larger deviations to the assigned values were observed compared to NMHC_N2 (77% of the reported values were within the GAW DQOs, but only 48% within the ACTRIS DQOs). Important contributors to the poorer performance in NMHC_air compared to NMHC_N2 were a more complex matrix and a larger span of NMHC mole fractions (0.03-2.5 nmol mol-1). Issues, which affected both NMHC mixtures, are the usage of direct vs. two-step calibration, breakthrough of C2-C3 hydrocarbons, blank values in zero-gas measurements (especially for those systems using a Nafion® Dryer), adsorptive losses of aromatic compounds, and insufficient chromatographic resolution. Essential for high-quality results are experienced operators, a comprehensive quality assurance and quality control, well characterised systems, and sufficient man-power to operate the systems and evaluate the data.

  14. Report: Performance Track Could Improve Program Design and Management to Ensure Value

    EPA Pesticide Factsheets

    Report #2007-P-00013, March 29, 2007. We found that Performance Track did not have clear plans that connected activities with its goals, and did not have performance measures that show if it achieves anticipated results.

  15. What can the national quality forum tell us about performance measurement in anesthesiology?

    PubMed

    Hyder, Joseph A; Niconchuk, Jonathan; Glance, Laurent G; Neuman, Mark D; Cima, Robert R; Dutton, Richard P; Nguyen, Louis L; Fleisher, Lee A; Bader, Angela M

    2015-02-01

    Anesthesiologists face increasing pressure to demonstrate the value of the care they provide, whether locally or nationally through public reporting and payor requirements. In this article, we describe the current state of performance measurement in anesthesia care at the national level and highlight gaps and opportunities in performance measurement for anesthesiologists. We evaluated all endorsed performance measures in the National Quality Forum (NQF), the clearinghouse for all federal performance measures, and classified all measures as follows: (1) anesthesia-specific; (2) surgery-specific; (3) jointly attributable; or (4) other. We used NQF-provided descriptors to characterize measures in terms of (1) structure, process, outcome, or efficiency; (2) patients, disease, and events targeted; (3) procedural specialty; (4) reporting eligibility; (5) measures stewards; and (6) timing in the care stream. Of the 637 endorsed performance measures, few (6, 1.0%) were anesthesia-specific. An additional 39 measures (6.1%) were surgery-specific, and 67 others (10.5%) were jointly attributable. "Anesthesia-specific" measures addressed preoperative antibiotic timing (n = 4), normothermia (n = 1), and protocol use for the placement of central venous catheter (n = 1). Jointly attributable measures included outcome measures (n = 49/67, 73.1%), which were weighted toward mortality alone (n = 24) and cardiac surgery (n = 14). Other jointly attributable measures addressed orthopedic surgery (n = 4), general surgical oncologic resections (n = 12), or nonspecified surgeries (n = 15), but none specifically addressed anesthesia care outside the operating room such as for endoscopy. Only 4 measures were eligible for value-based purchasing. No named anesthesiology professional groups were among measure stewards, but surgical professional groups (n = 33/67, 47%) were frequent measure stewards. Few NQF performance measures are specific to anesthesia practice, and none of these appears to demonstrate the value of anesthesia care or differentiate high-quality providers. To demonstrate their role in patient-centered, outcome-driven care, anesthesiologists may consider actively partnering in jointly attributable or team-based reporting. Future measures may incorporate surgical procedures not proportionally represented, as well as procedural and sedation care provided in nonoperating room settings.

  16. Examining the Relationship of an All-Cause Harm Patient Safety Measure and Critical Performance Measures at the Frontline of Care.

    PubMed

    Sammer, Christine; Hauck, Loran D; Jones, Cason; Zaiback-Aldinger, Julie; Li, Michael; Classen, David

    2018-02-07

    In 2015, the Institute of Medicine Vital Signs report called for a new patient safety composite measure to lessen the reporting burden of patient harm. Before this report, two patient safety organizations had developed an electronic all-cause harm measurement system leveraging data from the electronic health record, which identified and grouped harms into five broad categories and consolidated them into one all-cause harm outcome measure. The objective of this study was to examine the relationship between this all-cause harm patient safety measure and the following three performance measures important to overall hospital safety performance: safety culture, employee engagement, and patient experience. We studied the relationship between all-cause harm and three performance measures on eight inpatient care units at one hospital for 7 months. The findings demonstrated strong correlations between an all-cause harm measure and patient safety culture, employee engagement, and patient experience at the hospital unit level. Four safety culture domains showed significant negative correlations with all-cause harm at a P value of 0.05 or less. Six employee engagement domains were significantly negatively correlated with all-cause harm at a P value of 0.01 or less, and six of the ten patient experience measures were significantly correlated with all-cause harm at a P value of 0.05 or less. The results show that there is a strong relationship between all-cause harm and these performance measures indicating that when there is a positive patient safety culture, a more engaged employee, and a more satisfying patient experience, there may be less all-cause harm.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.

  17. Application of nonlinear least-squares regression to ground-water flow modeling, west-central Florida

    USGS Publications Warehouse

    Yobbi, D.K.

    2000-01-01

    A nonlinear least-squares regression technique for estimation of ground-water flow model parameters was applied to an existing model of the regional aquifer system underlying west-central Florida. The regression technique minimizes the differences between measured and simulated water levels. Regression statistics, including parameter sensitivities and correlations, were calculated for reported parameter values in the existing model. Optimal parameter values for selected hydrologic variables of interest are estimated by nonlinear regression. Optimal estimates of parameter values are about 140 times greater than and about 0.01 times less than reported values. Independently estimating all parameters by nonlinear regression was impossible, given the existing zonation structure and number of observations, because of parameter insensitivity and correlation. Although the model yields parameter values similar to those estimated by other methods and reproduces the measured water levels reasonably accurately, a simpler parameter structure should be considered. Some possible ways of improving model calibration are to: (1) modify the defined parameter-zonation structure by omitting and/or combining parameters to be estimated; (2) carefully eliminate observation data based on evidence that they are likely to be biased; (3) collect additional water-level data; (4) assign values to insensitive parameters, and (5) estimate the most sensitive parameters first, then, using the optimized values for these parameters, estimate the entire data set.

  18. Quantitative Assessment of Breast Cosmetic Outcome After Whole-Breast Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reddy, Jay P.; Lei, Xiudong; Huang, Sheng-Cheng

    Purpose: To measure, by quantitative analysis of digital photographs, breast cosmetic outcome within the setting of a randomized trial of conventionally fractionated (CF) and hypofractionated (HF) whole-breast irradiation (WBI), to identify how quantitative cosmesis metrics were associated with patient- and physician-reported cosmesis and whether they differed by treatment arm. Methods and Materials: From 2011 to 2014, 287 women aged ≥40 with ductal carcinoma in situ or early invasive breast cancer were randomized to HF-WBI (42.56 Gy/16 fractions [fx] + 10-12.5 Gy/4-5 fx boost) or CF-WBI (50 Gy/25 fx + 10-14 Gy/5-7 fx). At 1 year after treatment we collected digital photographs, patient-reported cosmesis using the Breast Cancer Treatment and Outcomesmore » Scale, and physician-reported cosmesis using the Radiation Therapy Oncology Group scale. Six quantitative measures of breast symmetry, labeled M1-M6, were calculated from anteroposterior digital photographs. For each measure, values closer to 1 imply greater symmetry, and values closer to 0 imply greater asymmetry. Associations between M1-M6 and patient- and physician-reported cosmesis and treatment arm were evaluated using the Kruskal-Wallis test. Results: Among 245 evaluable patients, patient-reported cosmesis was strongly associated with M1 (vertical symmetry measure) (P<.01). Physician-reported cosmesis was similarly correlated with M1 (P<.01) and also with M2 (vertical symmetry, P=.01) and M4 (horizontal symmetry, P=.03). At 1 year after treatment, HF-WBI resulted in better values of M2 (P=.02) and M3 (P<.01) than CF-WBI; treatment arm was not significantly associated with M1, M4, M5, or M6 (P≥.12). Conclusions: Quantitative assessment of breast photographs reveals similar to improved cosmetic outcome with HF-WBI compared with CF-WBI 1 year after treatment. Assessing cosmetic outcome using these measures could be useful for future comparative effectiveness studies and outcome reporting.« less

  19. Quantitative Assessment of Breast Cosmetic Outcome After Whole-Breast Irradiation.

    PubMed

    Reddy, Jay P; Lei, Xiudong; Huang, Sheng-Cheng; Nicklaus, Krista M; Fingeret, Michelle C; Shaitelman, Simona F; Hunt, Kelly K; Buchholz, Thomas A; Merchant, Fatima; Markey, Mia K; Smith, Benjamin D

    2017-04-01

    To measure, by quantitative analysis of digital photographs, breast cosmetic outcome within the setting of a randomized trial of conventionally fractionated (CF) and hypofractionated (HF) whole-breast irradiation (WBI), to identify how quantitative cosmesis metrics were associated with patient- and physician-reported cosmesis and whether they differed by treatment arm. From 2011 to 2014, 287 women aged ≥40 with ductal carcinoma in situ or early invasive breast cancer were randomized to HF-WBI (42.56 Gy/16 fractions [fx] + 10-12.5 Gy/4-5 fx boost) or CF-WBI (50 Gy/25 fx + 10-14 Gy/5-7 fx). At 1 year after treatment we collected digital photographs, patient-reported cosmesis using the Breast Cancer Treatment and Outcomes Scale, and physician-reported cosmesis using the Radiation Therapy Oncology Group scale. Six quantitative measures of breast symmetry, labeled M1-M6, were calculated from anteroposterior digital photographs. For each measure, values closer to 1 imply greater symmetry, and values closer to 0 imply greater asymmetry. Associations between M1-M6 and patient- and physician-reported cosmesis and treatment arm were evaluated using the Kruskal-Wallis test. Among 245 evaluable patients, patient-reported cosmesis was strongly associated with M1 (vertical symmetry measure) (P<.01). Physician-reported cosmesis was similarly correlated with M1 (P<.01) and also with M2 (vertical symmetry, P=.01) and M4 (horizontal symmetry, P=.03). At 1 year after treatment, HF-WBI resulted in better values of M2 (P=.02) and M3 (P<.01) than CF-WBI; treatment arm was not significantly associated with M1, M4, M5, or M6 (P≥.12). Quantitative assessment of breast photographs reveals similar to improved cosmetic outcome with HF-WBI compared with CF-WBI 1 year after treatment. Assessing cosmetic outcome using these measures could be useful for future comparative effectiveness studies and outcome reporting. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. The Applicability of Standard Error of Measurement and Minimal Detectable Change to Motor Learning Research-A Behavioral Study.

    PubMed

    Furlan, Leonardo; Sterr, Annette

    2018-01-01

    Motor learning studies face the challenge of differentiating between real changes in performance and random measurement error. While the traditional p -value-based analyses of difference (e.g., t -tests, ANOVAs) provide information on the statistical significance of a reported change in performance scores, they do not inform as to the likely cause or origin of that change, that is, the contribution of both real modifications in performance and random measurement error to the reported change. One way of differentiating between real change and random measurement error is through the utilization of the statistics of standard error of measurement (SEM) and minimal detectable change (MDC). SEM is estimated from the standard deviation of a sample of scores at baseline and a test-retest reliability index of the measurement instrument or test employed. MDC, in turn, is estimated from SEM and a degree of confidence, usually 95%. The MDC value might be regarded as the minimum amount of change that needs to be observed for it to be considered a real change, or a change to which the contribution of real modifications in performance is likely to be greater than that of random measurement error. A computer-based motor task was designed to illustrate the applicability of SEM and MDC to motor learning research. Two studies were conducted with healthy participants. Study 1 assessed the test-retest reliability of the task and Study 2 consisted in a typical motor learning study, where participants practiced the task for five consecutive days. In Study 2, the data were analyzed with a traditional p -value-based analysis of difference (ANOVA) and also with SEM and MDC. The findings showed good test-retest reliability for the task and that the p -value-based analysis alone identified statistically significant improvements in performance over time even when the observed changes could in fact have been smaller than the MDC and thereby caused mostly by random measurement error, as opposed to by learning. We suggest therefore that motor learning studies could complement their p -value-based analyses of difference with statistics such as SEM and MDC in order to inform as to the likely cause or origin of any reported changes in performance.

  1. United States Population-Based Estimates of Patient-Reported Outcomes Measurement Information System Symptom and Functional Status Reference Values for Individuals With Cancer.

    PubMed

    Jensen, Roxanne E; Potosky, Arnold L; Moinpour, Carol M; Lobo, Tania; Cella, David; Hahn, Elizabeth A; Thissen, David; Smith, Ashley Wilder; Ahn, Jaeil; Luta, George; Reeve, Bryce B

    2017-06-10

    Purpose To estimate cancer population-based reference values in the United States for eight PROMIS (Patient-Reported Outcomes Measurement Information System) domains by age and stage of disease. Patients and Methods For the Measuring Your Health (MY-Health) study, persons newly diagnosed with cancer (prostate, colorectal, non-small-cell lung, non-Hodgkin lymphoma, breast, uterine, or cervical) from 2010 to 2012 (N = 5,284) were recruited through the National Cancer Institute's SEER Program. Participants were mailed surveys 6 to 13 months after diagnosis. Raking by race/ethnicity, age, and stage generated weighted average PROMIS scores for pain interference, fatigue, anxiety, depression, sleep disturbance, physical function, ability to participate in social roles, and cognitive function. PROMIS measures are standardized to a T-score metric, with a score of 50 representing the general US population mean. Clinically meaningful differences were defined as a 3-point difference in scores. Results Several reference values (means) for patients with cancer were worse than the general United States population norms of 50. These include pain interference (52.4), fatigue (52.2), and physical function (44.1). Reference values were highest (ie, showed greatest symptom burden) in lung cancer (pain interference, 55.5; fatigue, 57.3; depression, 51.4) and cervical cancer (anxiety, 53.2; sleep disturbance, 53.4). Reference values for patients age 65 to 84 years reported lower sleep disturbance, anxiety, and depression, and better cognitive function than younger patients. Cancer reference values were poorer among those with advanced disease compared with patients with limited or no evidence of disease, specifically physical function (41.1 v 46.6, respectively), fatigue (55.8 v 50.2, respectively), and pain interference (55.2 v 50.9, respectively). Conclusion In a large, population-based sample of patients with recently diagnosed cancer, we observed symptom severity and functional deficits by age, stage, and cancer type consistent with the expected impact of cancer diagnosis and treatment. These United States cancer reference values can help facilitate interpretation of the PROMIS domain scores in research studies or in clinical applications that measure and evaluate the symptom and functional burden patients with cancer experience after initial treatment.

  2. Conclusions about children's reporting accuracy for energy and macronutrients over multiple interviews depend on the analytic approach for comparing reported information to reference information.

    PubMed

    Baxter, Suzanne Domel; Smith, Albert F; Hardin, James W; Nichols, Michele D

    2007-04-01

    Validation study data are used to illustrate that conclusions about children's reporting accuracy for energy and macronutrients over multiple interviews (ie, time) depend on the analytic approach for comparing reported and reference information-conventional, which disregards accuracy of reported items and amounts, or reporting-error-sensitive, which classifies reported items as matches (eaten) or intrusions (not eaten), and amounts as corresponding or overreported. Children were observed eating school meals on 1 day (n=12), or 2 (n=13) or 3 (n=79) nonconsecutive days separated by >or=25 days, and interviewed in the morning after each observation day about intake the previous day. Reference (observed) and reported information were transformed to energy and macronutrients (ie, protein, carbohydrate, and fat), and compared. For energy and each macronutrient: report rates (reported/reference), correspondence rates (genuine accuracy measures), and inflation ratios (error measures). Mixed-model analyses. Using the conventional approach for analyzing energy and macronutrients, report rates did not vary systematically over interviews (all four P values >0.61). Using the reporting-error-sensitive approach for analyzing energy and macronutrients, correspondence rates increased over interviews (all four P values <0.04), indicating that reporting accuracy improved over time; inflation ratios decreased, although not significantly, over interviews, also suggesting that reporting accuracy improved over time. Correspondence rates were lower than report rates, indicating that reporting accuracy was worse than implied by conventional measures. When analyzed using the reporting-error-sensitive approach, children's dietary reporting accuracy for energy and macronutrients improved over time, but the conventional approach masked improvements and overestimated accuracy. The reporting-error-sensitive approach is recommended when analyzing data from validation studies of dietary reporting accuracy for energy and macronutrients.

  3. Aircraft Speed Instruments

    NASA Technical Reports Server (NTRS)

    Beij, K Hilding

    1933-01-01

    This report presents a concise survey of the measurement of air speed and ground speed on board aircraft. Special attention is paid to the pitot-static air-speed meter which is the standard in the United States for airplanes. Air-speed meters of the rotating vane type are also discussed in considerable detail on account of their value as flight test instruments and as service instruments for airships. Methods of ground-speed measurement are treated briefly, with reference to the more important instruments. A bibliography on air-speed measurement concludes the report.

  4. Measurement of 13C chemical shift tensor principal values with a magic-angle turning experiment.

    PubMed

    Hu, J Z; Orendt, A M; Alderman, D W; Pugmire, R J; Ye, C; Grant, D M

    1994-08-01

    The magic-angle turning (MAT) experiment introduced by Gan is developed into a powerful and routine method for measuring the principal values of 13C chemical shift tensors in powdered solids. A large-volume MAT probe with stable rotation frequencies down to 22 Hz is described. A triple-echo MAT pulse sequence is introduced to improve the quality of the two-dimensional baseplane. It is shown that measurements of the principal values of chemical shift tensors in complex compounds can be enhanced by using either short contact times or dipolar dephasing pulse sequences to isolate the powder patterns from protonated or non-protonated carbons, respectively. A model compound, 1,2,3-trimethoxybenzene, is used to demonstrate these techniques, and the 13C principal values in 2,3-dimethylnaphthalene and Pocahontas coal are reported as typical examples.

  5. Increased internal higher-order aberrations as a useful parameter for indication of vitrectomy in three asteroid hyalosis cases

    PubMed Central

    Yokoyama, Sho; Kojima, Takashi; Kaga, Tatsushi; Ichikawa, Kazuo

    2015-01-01

    We report three asteroid hyalosis cases in which internal higher-order aberrations (HOAs) were improved concomitant with improved visual symptoms after vitrectomy. Cases 1 and 2 reported severe floaters and glare disability, although their visual acuities were fairly good. Case 3 showed poor visual acuity since this patient also suffered from mild macular degeneration. For these three asteroid hyalosis cases, we were unsure if treatment with vitrectomy could improve visual symptoms. Therefore, we measured internal HOAs with an aberrometer, and found that the internal HOA values in these cases were high. We suspected that internal high HOAs values were associated with visual disturbance, and performed vitrectomy. After the vitrectomy, the internal HOA values in these three asteroid hyalosis cases markedly decreased, and visual symptoms improved. These observations suggested that measurement of internal HOAs may be useful to determine the indication for vitrectomy. PMID:26698200

  6. Homogenization of the lipid profile values.

    PubMed

    Pedro-Botet, Juan; Rodríguez-Padial, Luis; Brotons, Carlos; Esteban-Salán, Margarita; García-Lerín, Aurora; Pintó, Xavier; Lekuona, Iñaki; Ordóñez-Llanos, Jordi

    Analytical reports from the clinical laboratory are essential to guide clinicians about what lipid profile values should be considered altered and, therefore, require intervention. Unfortunately, there is a great heterogeneity in the lipid values reported as "normal, desirable, recommended or referenced" by clinical laboratories. This can difficult clinical decisions and be a barrier to achieve the therapeutic goals for cardiovascular prevention. A recent international recommendation has added a new heterogeneity factor for the interpretation of lipid profile, such as the possibility of measuring it without previous fasting. All this justifies the need to develop a document that adapts the existing knowledge to the clinical practice of our health system. In this regard, professionals from different scientific societies involved in the measurement and use of lipid profile data have developed this document to establish recommendations that facilitate their homogenization. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  7. Increased internal higher-order aberrations as a useful parameter for indication of vitrectomy in three asteroid hyalosis cases.

    PubMed

    Yokoyama, Sho; Kojima, Takashi; Kaga, Tatsushi; Ichikawa, Kazuo

    2015-12-23

    We report three asteroid hyalosis cases in which internal higher-order aberrations (HOAs) were improved concomitant with improved visual symptoms after vitrectomy. Cases 1 and 2 reported severe floaters and glare disability, although their visual acuities were fairly good. Case 3 showed poor visual acuity since this patient also suffered from mild macular degeneration. For these three asteroid hyalosis cases, we were unsure if treatment with vitrectomy could improve visual symptoms. Therefore, we measured internal HOAs with an aberrometer, and found that the internal HOA values in these cases were high. We suspected that internal high HOAs values were associated with visual disturbance, and performed vitrectomy. After the vitrectomy, the internal HOA values in these three asteroid hyalosis cases markedly decreased, and visual symptoms improved. These observations suggested that measurement of internal HOAs may be useful to determine the indication for vitrectomy. 2015 BMJ Publishing Group Ltd.

  8. Physical property measurements of doped cesium iodide crystals

    NASA Technical Reports Server (NTRS)

    Synder, R. S.; Clotfelter, W. N.

    1974-01-01

    Mechanical and thermal property values are reported for crystalline cesium iodide doped with sodium and thallium. Young's modulus, bulk modulus, shear modulus, and Poisson's ratio were obtained from ultrasonic measurements. Young's modulus and the samples' elastic and plastic behavior were also measured under tension and compression. Thermal expansion and thermal conductivity were the temperature dependent measurements that were made.

  9. Adherence to outpatient epilepsy quality indicators at a tertiary epilepsy center

    PubMed Central

    Pourdeyhimi, R.; Wolf, B.J.; Simpson, A.N.; Martz, G.U.

    2014-01-01

    Introduction Quality indicators for the treatment of people with epilepsy were published in 2010. This is the first report of adherence to all measures in routine care of people with epilepsy at a level 4 comprehensive epilepsy center in the US. Methods Two hundred patients with epilepsy were randomly selected from the clinics of our comprehensive epilepsy center, and all visits during 2011 were abstracted for documentation of adherence to the eight quality indicators. Alternative measures were constructed to evaluate failure of adherence. Detailed descriptions of all equations are provided. Results Objective measures (EEG, imaging) showed higher adherence than counseling measures (safety). Initial visits showed higher adherence. Variations in the interpretation of the quality measure result in different adherence values. Advanced practice providers and physicians had different adherence patterns. No patient-specific patterns of adherence were seen. Discussion This is the first report of adherence to all the epilepsy quality indicators for a sample of patients during routine care in a level 4 epilepsy center in the US. Overall adherence was similar to that previously reported on similar measures. Precise definitions of adherence equations are essential for accurate measurement. Complex measures result in lower adherence. Counseling measures showed low adherence, possibly highlighting a difference between practice and documentation. Adherence to the measures as written does not guarantee high quality care. Conclusion The current quality indicators have value in the process of improving quality of care. Future approaches may be refined to eliminate complex measures and incorporate features linked to outcomes. PMID:25171260

  10. Report of the ACR's Economics Committee on Value-Based Payment Models.

    PubMed

    Boland, Giles W; Glenn, Lucille; Goldberg-Stein, Shlomit; Jha, Saurabh; Mangano, Mark; Patel, Samir; Schoppe, Kurt A; Seidenwurm, David; Lohnes, John; Silva, Ezequiel; Abramson, Richard; Durand, Daniel J; Pattie, Laura; Kassing, Pamela; Heller, Richard E

    2017-01-01

    A major outcome of the current health care reform process is the move away from unrestricted fee-for-service payment models toward those that are based on the delivery of better patient value and outcomes. The authors' purpose, therefore, is to critically evaluate and define those components of the overall imaging enterprise that deliver meaningful value to both patients and referrers and to determine how these components might be measured and quantified. These metrics might then be used to lobby providers and payers for sustainable payment solutions for radiologists and radiology services. The authors evaluated radiology operations and services using the framework of the imaging value chain, which divides radiology service into a number of discrete value-added activities, which ultimately deliver the primary product, most often the actionable report for diagnostic imaging or an effective outcome for interventional radiology. These value activities include scheduling and imaging appropriateness and stewardship, patient preparation, protocol design, modality operations, reporting, report communication, and clinical follow-up (eg, mammography reminder letters). Two further categories are hospital or health care organization citizenship and examination outcome. Each is discussed in turn, with specific activities highlighted. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  11. Evaporation Kinetics of Polyol Droplets: Determination of Evaporation Coefficients and Diffusion Constants

    NASA Astrophysics Data System (ADS)

    Su, Yong-Yang; Marsh, Aleksandra; Haddrell, Allen E.; Li, Zhi-Ming; Reid, Jonathan P.

    2017-11-01

    In order to quantify the kinetics of mass transfer between the gas and condensed phases in aerosol, physicochemical properties of the gas and condensed phases and kinetic parameters (mass/thermal accommodation coefficients) are crucial for estimating mass fluxes over a wide size range from the free molecule to continuum regimes. In this study, we report measurements of the evaporation kinetics of droplets of 1-butanol, ethylene glycol (EG), diethylene glycol (DEG), and glycerol under well-controlled conditions (gas flow rates and temperature) using the previously developed cylindrical electrode electrodynamic balance technique. Measurements are compared with a model that captures the heat and mass transfer occurring at the evaporating droplet surface. The aim of these measurements is to clarify the discrepancy in the reported values of mass accommodation coefficient (αM, equals to evaporation coefficient based on microscopic reversibility) for 1-butanol, EG, and DEG and improve the accuracy of the value of the diffusion coefficient for glycerol in gaseous nitrogen. The uncertainties in the thermophysical and experimental parameters are carefully assessed, the literature values of the vapor pressures of these components are evaluated, and the plausible ranges of the evaporation coefficients for 1-butanol, EG, and DEG as well as uncertainty in diffusion coefficient for glycerol are reported. Results show that αM should be greater than 0.4, 0.2, and 0.4 for EG, DEG, and 1-butanol, respectively. The refined values are helpful for accurate prediction of the evaporation/condensation rates.

  12. Adding Albedo and Atmospheres

    ERIC Educational Resources Information Center

    LoPresto, Michael C.

    2013-01-01

    In a previous article in this journal, we reported on a laboratory activity in which students used a derivation from the Stefan-Boltzmann law to calculate planetary temperatures and compare them to measured values from various (mostly online) sources. The calculated temperatures matched observed values very well with the exceptions of Venus and…

  13. Values and Attitudes of Medical Students at an Australian University.

    ERIC Educational Resources Information Center

    Feather, N. T.

    1981-01-01

    The results of an Australian study in which medical students at Flinders University were tested and retested to trace changes in their attitudes and values since their freshman year are reported. Specific attitude items concerned with federal government intervention in health insurance were measured. (Author/MLW)

  14. Measurement and Model Linkages in Assessing School Environments.

    ERIC Educational Resources Information Center

    Schmitt, Neal

    Detailed methodology used to evaluate a causal model of school environment is presented in this report. The model depicts societal features that influence school district values and organizational characteristics, which in turn influence school operations and personnel attitudes and values. These school variables affect school community members'…

  15. Results of the supplementary comparison SIM.M.FF-S12 for volume of liquids at 20 L

    NASA Astrophysics Data System (ADS)

    Maldonado, M.; Castillo, E.; Rodríguez, L. D.

    2018-01-01

    A supplementary comparison was performed in order to compare national measurement systems to determine volume of liquids, particularly at fixed volume of 20 L. The participants were CENAM (Mexico), LACOMET (Costa Rica) and RECOPE (Costa Rica). The measurements were carried out from October 2016 to June 2017. The chosen value of volume (20 L) is representative of the Calibration and Measurement Capabilities (CMCs) declared by the three participants. The transfer standard (TS) was a stainless steel pipette for volume at 20 L. Prior to the beginning of the comparison, the TS was tested by CENAM. The results of the test phase showed excellent values for both repeatability and reproducibility. During the SIM.M.FF-S12, the results of the laboratories showed good agreement with the reference values. The best estimation of the measurands, as reported by the participants, showed a +/- 0.0022 % as the largest difference among the laboratories. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Predictive value of autoantibody testing for validating self-reported diagnoses of rheumatoid arthritis in the Women's Health Initiative.

    PubMed

    Walitt, Brian; Mackey, Rachel; Kuller, Lewis; Deane, Kevin D; Robinson, William; Holers, V Michael; Chang, Yue-Fang; Moreland, Larry

    2013-05-01

    Rheumatoid arthritis (RA) research using large databases is limited by insufficient case validity. Of 161,808 postmenopausal women in the Women's Health Initiative, 15,691 (10.2%) reported having RA, far higher than the expected 1% population prevalence. Since chart review for confirmation of an RA diagnosis is impractical in large cohort studies, the current study (2009-2011) tested the ability of baseline serum measurements of rheumatoid factor and anti-cyclic citrullinated peptide antibodies, second-generation assay (anti-CCP2), to identify physician-validated RA among the chart-review study participants with self-reported RA (n = 286). Anti-CCP2 positivity had the highest positive predictive value (PPV) (80.0%), and rheumatoid factor positivity the lowest (44.6%). Together, use of disease-modifying antirheumatic drugs and anti-CCP2 positivity increased PPV to 100% but excluded all seronegative cases (approximately 15% of all RA cases). Case definitions inclusive of seronegative cases had PPVs between 59.6% and 63.6%. False-negative results were minimized in these test definitions, as evidenced by negative predictive values of approximately 90%. Serological measurements, particularly measurement of anti-CCP2, improved the test characteristics of RA case definitions in the Women's Health Initiative.

  17. Nomograms for two-dimensional echocardiography derived valvular and arterial dimensions in Caucasian children.

    PubMed

    Cantinotti, Massimiliano; Giordano, Raffaele; Scalese, Marco; Murzi, Bruno; Assanta, Nadia; Spadoni, Isabella; Maura, Crocetti; Marco, Marotta; Molinaro, Sabrina; Kutty, Shelby; Iervasi, Giorgio

    2017-01-01

    Despite recent advances, current pediatric echocardiographic nomograms for valvular and arterial dimensions remain limited. We prospectively studied healthy Caucasian Italian children by two-dimensional (2D) echocardiography. Echocardiographic measurements for 18 valvular and arterial dimensions were performed and models were generated testing for linear, logarithmic, exponential, and square root relationships. Heteroscedasticity was accounted for by White or Breusch-Pagan test. Age, weight, height, heart rate, and body surface area (BSA) were used as independent variables in different analyses to predict the mean values of each measurement. Structured Z-scores were then computed. In all, 1151 subjects (age 0 days to 17 years; 45% females; BSA 0.12-2.12m 2 ) were studied. The Haycock formula was used when presenting data as predicted values (mean±2 SDs) for a given BSA and within equations relating echocardiographic measurements to BSA. The predicted values and Z-score boundaries for all measurements are presented. We report echocardiographic nomograms for valvular and arterial dimensions derived from a large population of children. Integration of these data with those of previous reports would allow for a comprehensive coverage of pediatric 2D echocardiographic nomograms for measurement of 2D cardiac structures. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fox, K. M.; Edwards, T. B.

    In this report, the Savannah River National Laboratory provides chemical analyses and Product Consistency Test (PCT) results for 14 simulated high level waste glasses fabricated by the Pacific Northwest National Laboratory. The results of these analyses will be used as part of efforts to revise or extend the validation regions of the current Hanford Waste Treatment and Immobilization Plant glass property models to cover a broader span of waste compositions. The measured chemical composition data are reported and compared with the targeted values for each component for each glass. All of the measured sums of oxides for the study glassesmore » fell within the interval of 96.9 to 100.8 wt %, indicating recovery of all components. Comparisons of the targeted and measured chemical compositions showed that the measured values for the glasses met the targeted concentrations within 10% for those components present at more than 5 wt %. The PCT results were normalized to both the targeted and measured compositions of the study glasses. Several of the glasses exhibited increases in normalized concentrations (NCi) after the canister centerline cooled (CCC) heat treatment. Five of the glasses, after the CCC heat treatment, had NC B values that exceeded that of the Environmental Assessment (EA) benchmark glass. These results can be combined with additional characterization, including X-ray diffraction, to determine the cause of the higher release rates.« less

  19. Remarks on the pion-nucleon σ-term

    NASA Astrophysics Data System (ADS)

    Hoferichter, Martin; Ruiz de Elvira, Jacobo; Kubis, Bastian; Meißner, Ulf-G.

    2016-09-01

    The pion-nucleon σ-term can be stringently constrained by the combination of analyticity, unitarity, and crossing symmetry with phenomenological information on the pion-nucleon scattering lengths. Recently, lattice calculations at the physical point have been reported that find lower values by about 3σ with respect to the phenomenological determination. We point out that a lattice measurement of the pion-nucleon scattering lengths could help resolve the situation by testing the values extracted from spectroscopy measurements in pionic atoms.

  20. High Precision Determination of the β Decay QEC Value of 11C and Implications on the Tests of the Standard Model

    NASA Astrophysics Data System (ADS)

    Gulyuz, K.; Bollen, G.; Brodeur, M.; Bryce, R. A.; Cooper, K.; Eibach, M.; Izzo, C.; Kwan, E.; Manukyan, K.; Morrissey, D. J.; Naviliat-Cuncic, O.; Redshaw, M.; Ringle, R.; Sandler, R.; Schwarz, S.; Sumithrarachchi, C. S.; Valverde, A. A.; Villari, A. C. C.

    2016-01-01

    We report the determination of the QEC value of the mirror transition of 11C by measuring the atomic masses of 11C and 11B using Penning trap mass spectrometry. More than an order of magnitude improvement in precision is achieved as compared to the 2012 Atomic Mass Evaluation (Ame2012) [Chin. Phys. C 36, 1603 (2012)]. This leads to a factor of 3 improvement in the calculated F t value. Using the new value, QEC=1981.690 (61 ) keV , the uncertainty on F t is no longer dominated by the uncertainty on the QEC value. Based on this measurement, we provide an updated estimate of the Gamow-Teller to Fermi mixing ratio and standard model values of the correlation coefficients.

  1. High Precision Determination of the β Decay Q(EC) Value of (11)C and Implications on the Tests of the Standard Model.

    PubMed

    Gulyuz, K; Bollen, G; Brodeur, M; Bryce, R A; Cooper, K; Eibach, M; Izzo, C; Kwan, E; Manukyan, K; Morrissey, D J; Naviliat-Cuncic, O; Redshaw, M; Ringle, R; Sandler, R; Schwarz, S; Sumithrarachchi, C S; Valverde, A A; Villari, A C C

    2016-01-08

    We report the determination of the Q(EC) value of the mirror transition of (11)C by measuring the atomic masses of (11)C and (11)B using Penning trap mass spectrometry. More than an order of magnitude improvement in precision is achieved as compared to the 2012 Atomic Mass Evaluation (Ame2012) [Chin. Phys. C 36, 1603 (2012)]. This leads to a factor of 3 improvement in the calculated Ft value. Using the new value, Q(EC)=1981.690(61)  keV, the uncertainty on Ft is no longer dominated by the uncertainty on the Q(EC) value. Based on this measurement, we provide an updated estimate of the Gamow-Teller to Fermi mixing ratio and standard model values of the correlation coefficients.

  2. Half-lives of 214Pb and 214Bi.

    PubMed

    Martz, D E; Langner, G H; Johnson, P R

    1991-10-01

    New measurements on chemically separated samples of 214Bi have yielded a mean half-life value of 19.71 +/- 0.02 min, where the error quoted is twice the standard deviation of the mean based on 23 decay runs. This result provides strong support for the historic 19.72 +/- 0.04 min half-life value and essentially excludes the 19.9-min value, both reported in previous studies. New measurements of the decay rate of 222Rn progeny activity initially in radioactive equilibrium have yielded a value of 26.89 +/- 0.03 min for the half-life of 214Pb, where the error quoted is twice the standard deviation of the mean based on 12 decay runs. This value is 0.1 min longer than the currently accepted 214Pb half-value of 26.8 min.

  3. An examination of the thermodynamics of fusion, vaporization, and sublimation of ibuprofen and naproxen by correlation gas chromatography.

    PubMed

    Maxwell, Rachel; Chickos, James

    2012-02-01

    The vaporization enthalpies of (S)-ibuprofen and (S)-naproxen measured by correlation gas chromatography at T = 298.15 K are reported and compared with literature values. Adjustment of the fusion enthalpies of (RS)- and (S)-ibuprofen and (S)-naproxen to T = 298.15 K and combined with the vaporization enthalpy of the (S)-enantiomer of both ibuprofen and naproxen also at T = 298.15 K resulted in the sublimation enthalpies of both (S)-enantiomers. On the assumption that the vaporization enthalpy of the racemic form of ibuprofen is within the experimental uncertainty of the chiral form, the sublimation enthalpy of racemic ibuprofen was also evaluated. The vaporization and sublimation enthalpies compare favorably to the most of the literature values for the racemic form of ibuprofen but differ from the value reported for chiral ibuprofen. The literature values of (S)-naproxen are somewhat smaller than the values measured in this work. The following vaporization enthalpies were measured for (S)-ibuprofen and (S)-naproxen, respectively: ΔH(vap) (298.15 K), 106.0 ± 5.5, 132.2 ± 5.0 kJ·mol(-1) . Sublimation enthalpies of 122.7 ± 5.6 and 155.2 ± 7.1 kJ·mol(-1) were calculated for the (S)-enantiomers of ibuprofen and naproxen and a value of 128.9 ± 5.8 kJ·mol(-1) was estimated for the racemic form of ibuprofen. Copyright © 2011 Wiley Periodicals, Inc.

  4. Brief Report: Can Metrics of Reporting Bias Enhance Early Autism Screening Measures?

    ERIC Educational Resources Information Center

    Taylor, Cora M.; Vehorn, Alison; Noble, Hylan; Weitlauf, Amy S.; Warren, Zachary E.

    2014-01-01

    The goal of the current study was to develop and pilot the utility of two simple internal response bias metrics, over-reporting and under-reporting, in terms of additive clinical value within common screening practices for early detection of autism spectrum disorder risk. Participants were caregivers and children under 36 months of age (n = 145)…

  5. APMP.QM-K111—propane in nitrogen

    NASA Astrophysics Data System (ADS)

    Lin, Tsai-Yin; Liu, Hsin-Wang; Huang, Chiung-Kun; Kang, Namgoo; Bae, Hyun Kil; Woo, Jin Chun; Bi, Zhe; Zhou, Zeyi; Sinweeruthai, Ratirat; Wongjuk, Arnuttachai; Li, Hou; Beng Keat, Teo; Hui, Liu; Wu, Thomas; Hock Ann, Chua; Smeulders, Damian; Briton McCallum, John; Tendai Satumba, Raymond; Shimosaka, Takuya; Matsumoto, Nobuhiro; Kadir, Haslina Abdul; Fauzi Ahmad, Mohamad; Nasir, Noor Hidaya Abdul; Nishino, Tomoe; Akima, Dai; Uehara, Shinji

    2018-01-01

    This document describes the result of a key comparison for propane in nitrogen. The nominal amount-of-substance fraction of propane is 1000 μmol/mol. The comparison aimed to assess the measurement capability of participants in gas analysis. Nine NMIs or DIs participated in the comparison. CERI participated in a key comparison CCQM-K111—propane in nitrogen, and coordinated this key comparison. Therefore, every participants' results of this comparison are linking to the CCQM-K111. Gravimetric values of the samples were used as key comparison reference values (KCRVs). Measured values of eight participants were within +/- 0.25 % of the KCRVs. Many participants reported purity or impurity analysis of materials. These results are also able to assess the participants' capability of the analysis. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Provider perceptions of the value of same-day, electronic patient-reported measures for use in clinical HIV care

    PubMed Central

    Fredericksen, RJ; Tufano, J; Ralston, J; McReynolds, J; Stewart, M; Lober, WB; Mayer, K; Mathews, WC; Mugavero, M; Crane, PK; Crane, HM

    2016-01-01

    Strong evidence suggests that patient-reported outcomes (PROs) aid in managing chronic conditions, reduce omissions in care, and improve patient-provider communication. However, provider acceptability of PROs and their use in clinical HIV care is not well known. We interviewed providers (n=27) from four geographically diverse HIV and community care clinics in the U.S. that have integrated PROs into routine HIV care, querying perceived value, challenges, and use of PRO data. Perceived benefits included the ability of PROs to identify less-observable behaviors and conditions, particularly suicidal ideation, depression, and substance use; usefulness in agenda-setting prior to a visit; and reduction of social desirability bias in patient-provider communication. Challenges included initial flow integration issues and ease of interpretation of PRO feedback. Providers value same-day, electronic patient-reported measures for use in clinical HIV care with the condition that PROs are 1) tailored to be the most clinically relevant to their population; 2) well-integrated into clinic flow; 3) easy to interpret, highlighting chief patient concerns and changes over time. PMID:27237187

  7. The PROMIS fatigue item bank has good measurement properties in patients with fibromyalgia and severe fatigue.

    PubMed

    Yost, Kathleen J; Waller, Niels G; Lee, Minji K; Vincent, Ann

    2017-06-01

    Efficient management of fibromyalgia (FM) requires precise measurement of FM-specific symptoms. Our objective was to assess the measurement properties of the Patient-Reported Outcome Measurement Information System (PROMIS) fatigue item bank (FIB) in people with FM. We applied classical psychometric and item response theory methods to cross-sectional PROMIS-FIB data from two samples. Data on the clinical FM sample were obtained at a tertiary medical center. Data for the U.S. general population sample were obtained from the PROMIS network. The full 95-item bank was administered to both samples. We investigated dimensionality of the item bank in both samples by separately fitting a bifactor model with two group factors; experience and impact. We assessed measurement invariance between samples, and we explored an alternate factor structure with the normative sample and subsequently confirmed that structure in the clinical sample. Finally, we assessed whether reporting FM subdomain scores added value over reporting a single total score. The item bank was dominated by a general fatigue factor. The fit of the initial bifactor model and evidence of measurement invariance indicated that the same constructs were measured across the samples. An alternative bifactor model with three group factors demonstrated slightly improved fit. Subdomain scores add value over a total score. We demonstrated that the PROMIS-FIB is appropriate for measuring fatigue in clinical samples of FM patients. The construct can be presented by a single score; however, subdomain scores for the three group factors identified in the alternative model may also be reported.

  8. Test Report for NG Sensors GTX-1000

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manginell, Ronald P.

    2014-12-01

    This report describes initial testing of the NG Sensor GTX-1000 natural gas monitoring system. This testing showed that the retention time, peak area stability and heating value repeatability of the GTX-1000 were promising for natural gas measurements in the field or at the well head. The repeatability can be less than 0.25% for LHV and HHV for the Airgas standard tested in this report, which is very promising for a first generation prototype. Ultimately this system should be capable of 0.1% repeatability in heating value at significant size and power reductions compared with competing systems.

  9. Radioactivity levels in the marine environment along the Exclusive Economic Zone (EEZ) of Qatar.

    PubMed

    Al-Qaradawi, Ilham; Abdel-Moati, Mohamed; Al-Yafei, Mohsin Al-Ansi; Al-Ansari, Ebrahim; Al-Maslamani, Ibrahim; Holm, Elis; Al-Shaikh, Ismail; Mauring, Alexander; Pinto, Primal V; Abdulmalik, Dana; Amir, Amina; Miller, Mark; Yigiterhan, Oguz; Persson, Bertil

    2015-01-15

    A study on (137)Cs, (40)K, (226)Ra, (228)Ra, and (238)U was carried out along the EEZ of Qatar. Results serve as the first ever baseline data. The level of (137)Cs (mean value 1.6 ± 0.4 Bq m(-3)) in water filters was found to be in the same order of magnitude as reported by others in worldwide marine radioactivity studies. Results are also in agreement with values reported from other Gulf regions. The computed values of sediment-water distribution coefficients Kd, are lower than the values given by IAEA. Measurements were carried out for bottom sediments, biota samples like fish, oyster, sponge, seashell, mangrove, crab, shrimp, starfish, dugong and algae. The 'concentration factors' reported for biota samples are below the levels published by IAEA and cause no significant impact on human health for seafood consumers in Qatar. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Light-pollution measurement with the Wide-field all-sky image analyzing monitoring system

    NASA Astrophysics Data System (ADS)

    Vítek, S.

    2017-07-01

    The purpose of this experiment was to measure light pollution in the capital of Czech Republic, Prague. As a measuring instrument is used calibrated consumer level digital single reflex camera with IR cut filter, therefore, the paper reports results of measuring and monitoring of the light pollution in the wavelength range of 390 - 700 nm, which most affects visual range astronomy. Combining frames of different exposure times made with a digital camera coupled with fish-eye lens allow to create high dynamic range images, contain meaningful values, so such a system can provide absolute values of the sky brightness.

  11. The Royal Australian and New Zealand College of Radiologists (RANZCR) relative value unit workload model, its limitations and the evolution to a safety, quality and performance framework.

    PubMed

    Pitman, A; Jones, D N; Stuart, D; Lloydhope, K; Mallitt, K; O'Rourke, P

    2009-10-01

    The study reports on the evolution of the Australian radiologist relative value unit (RVU) model of measuring radiologist reporting workloads in teaching hospital departments, and aims to outline a way forward for the development of a broad national safety, quality and performance framework that enables value mapping, measurement and benchmarking. The Radiology International Benchmarking Project of Queensland Health provided a suitable high-level national forum where the existing Pitman-Jones RVU model was applied to contemporaneous data, and its shortcomings and potential avenues for future development were analysed. Application of the Pitman-Jones model to Queensland data and also a Victorian benchmark showed that the original recommendation of 40,000 crude RVU per full-time equivalent consultant radiologist (97-98 baseline level) has risen only moderately, to now lie around 45,000 crude RVU/full-time equivalent. Notwithstanding this, the model has a number of weaknesses and is becoming outdated, as it cannot capture newer time-consuming examinations particularly in CT. A significant re-evaluation of the value of medical imaging is required, and is now occurring. We must rethink how we measure, benchmark, display and continually improve medical imaging safety, quality and performance, throughout the imaging care cycle and beyond. It will be necessary to ensure alignment with patient needs, as well as clinical and organisational objectives. Clear recommendations for the development of an updated national reporting workload RVU system are available, and an opportunity now exists for developing a much broader national model. A more sophisticated and balanced multidimensional safety, quality and performance framework that enables measurement and benchmarking of all important elements of health-care service is needed.

  12. Determination of facial symmetry in unilateral cleft lip and palate patients from three-dimensional data: technical report and assessment of measurement errors.

    PubMed

    Nkenke, Emeka; Lehner, Bernhard; Kramer, Manuel; Haeusler, Gerd; Benz, Stefanie; Schuster, Maria; Neukam, Friedrich W; Vairaktaris, Eleftherios G; Wurm, Jochen

    2006-03-01

    To assess measurement errors of a novel technique for the three-dimensional determination of the degree of facial symmetry in patients suffering from unilateral cleft lip and palate malformations. Technical report, reliability study. Cleft Lip and Palate Center of the University of Erlangen-Nuremberg, Erlangen, Germany. The three-dimensional facial surface data of five 10-year-old unilateral cleft lip and palate patients were subjected to the analysis. Distances, angles, surface areas, and volumes were assessed twice. Calculations were made for method error, intraclass correlation coefficient, and repeatability of the measurements of distances, angles, surface areas, and volumes. The method errors were less than 1 mm for distances and less than 1.5 degrees for angles. The intraclass correlation coefficients showed values greater than .90 for all parameters. The repeatability values were comparable for cleft and noncleft sides. The small method errors, high intraclass correlation coefficients, and comparable repeatability values for cleft and noncleft sides reveal that the new technique is appropriate for clinical use.

  13. EURAMET.M.P-S9: comparison in the negative gauge pressure range -950 to 0 hPa

    NASA Astrophysics Data System (ADS)

    Saxholm, S.; Otal, P.; AltintaS, A.; Bermanec, L. G.; Durgut, Y.; Hanrahan, R.; Kocas, I.; Lefkopoulos, A.; Pražák, D.; Sandu, I.; Åetina, J.; Spohr, I.; Steindl, D.; Tammik, K.; Testa, N.

    2016-01-01

    A comparison in the negative gauge pressure range was arranged in the period 2011 - 2012. A total of 14 laboratories participated in this comparison: BEV (Austria), CMI (Czech Republic), DANIAmet-FORCE (Denmark), EIM (Greece), HMI/FSB-LPM (Croatia), INM (Romania), IPQ (Portugal), LNE (France), MCCAA (Malta), METROSERT (Estonia), MIKES (Finland), MIRS/IMT/LMT (Slovenia), NSAI (Ireland) and UME (Turkey). The project was divided into two loops: Loop1, piloted by MIKES, and Loop2, piloted by LNE. The results of the two loops are reported separately: Loop1 results are presented in this paper. The transfer standard was Beamex MC5 no. 25516865 with internal pressure module INT1C, resolution 0.01 hPa. The nominal pressure range of the INT1C is -1000 hPa to +1000 hPa. The nominal pressure points for the comparison were 0 hPa, -200 hPa, -400 hPa, -600 hPa, -800 hPa and -950 hPa. The reference values and their uncertainties as well as the difference uncertainty between the laboratory results and the reference values were determined from the measurement data by Monte Carlo simulations. Stability uncertainty of the transfer standard was included in the final difference uncertainty. Degrees of equivalences and mutual equivalences between the laboratories were calculated. Each laboratory reported results for all twelve measurement points, which means that there were 168 reported values in total. Some 163 of the 168 values (97 %) agree with the reference values within the expanded uncertainties, with a coverage factor k = 2. Among the laboratories, four different methods were used to determine negative gauge pressure. It is concluded that special attention must be paid to the measurements and methods when measuring negative gauge pressures. There might be a need for a technical guide or a workshop that provides information about details and practices related to the measurements of negative gauge pressure, as well as differences between the different methods. The comparison is registered as EURAMET project no. 1170 and as a supplementary comparison EURAMET.M.P-S9 in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Incidence and trends of central line associated pneumothorax using radiograph report text search versus administrative database codes.

    PubMed

    Reeson, Marc; Forster, Alan; van Walraven, Carl

    2018-05-25

    Central line associated pneumothorax (CLAP) could be a good quality of care indicator because they are objectively measured, clearly undesirable and possibly avoidable. We measured the incidence and trends of CLAP using radiograph report text search with manual review and compared them with measures using routinely collected health administrative data. For each hospitalisation to a tertiary care teaching hospital between 2002 and 2015, we searched all chest radiography reports for a central line with a sensitive computer algorithm. Screen positive reports were manually reviewed to confirm central lines. The index and subsequent chest radiography reports were screened for pneumothorax followed by manual confirmation. Diagnostic and procedural codes were used to identify CLAP in administrative data. In 685 044 hospitalisations, 10 819 underwent central line insertion (1.6%) with CLAP occurring 181 times (1.7%). CLAP risk did not change over time. Codes for CLAP were inaccurate (sensitivity 13.8%, positive predictive value 6.6%). However, overall code-based CLAP risk (1.8%) was almost identical to actual values possibly because patient strata with inflated CLAP risk were balanced by more common strata having underestimated CLAP risk. Code-based methods inflated central line incidence 2.2 times and erroneously concluded that CLAP risk decreased significantly over time. Using valid methods, CLAP incidence was similar to those in the literature but has not changed over time. Although administrative database codes for CLAP were very inaccurate, they generated CLAP risks very similar to actual values because of offsetting errors. In contrast to those from radiograph report text search with manual review, CLAP trends decreased significantly using administrative data. Hospital CLAP risk should not be measured using administrative data. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Comparisons of measured and self-reported anthropometric variables and blood pressure in a sample of Hong Kong female nurses.

    PubMed

    Xie, Yao Jie; Ho, Suzanne C; Liu, Zhao Min; Hui, Stanley Sai-Chuen

    2014-01-01

    To assess the validity of self-reported weight, height, body mass index (BMI), waist circumference and blood pressure compared with standardized clinical measurements and to determine the classification accuracy in overweight/obesity and central adiposity. This pilot study was integrated into a life-course study entitled "Hong Kong Women's Health Study" among 1,253 female nurses in Hong Kong who were aged 35 years to 65 years. Data were collected from self-administered questionnaires that were mailed to the respondents. Of these participants, we obtained the standard body measurements of 144 (11.5%) at our research center. We then compared the self-reported anthropometric variables and blood pressure with the measured data to assess validity based on the level of misreporting, percentage of agreement, consistency, sensitivity and specificity. The self-reported and measured values were highly correlated in terms of anthropometry and blood pressure (correlation coefficients ranged from 0.72 to 0.96). Height was overestimated at an average of 0.42 cm, and waist circumference was underestimated at 2.33 cm (both P<0.05), while no significant differences were observed from weight, blood pressure and BMI (all P>0.05). The proportions of overweight, obesity, and central adiposity by self-reported data did not vary greatly from the measured data (all P>0.05). The self-reporting resulted in correct classifications of BMI, waist circumference, and systolic blood pressure in 85%, 78%, and 87% of women, with corresponding Kappa index values of 0.79, 0.55, and 0.82, respectively. Sensitivity and specificity were 84.6% and 95.7%, respectively, with respect to overweight/obesity detection, whereas those for central adiposity detection were 70.6% and 83.8%, respectively. In a sample of female Hong Kong nurses, the self-reported measures of height, weight, BMI, waist circumference and blood pressure were generally valid. Furthermore, the classification accuracies of overweight/obesity and central adiposity were acceptable.

  16. Patients’ perceived value of pharmacy quality measures: a mixed-methods study

    PubMed Central

    Shiyanbola, Olayinka O; Mort, Jane R

    2015-01-01

    Objective To describe patients’ perceived value and use of quality measures in evaluating and choosing community pharmacies. Design Focus group methodology was combined with a survey tool. During the focus groups, participants assessed the value of the Pharmacy Quality Alliance's quality measures in evaluating and choosing a pharmacy. Also, participants completed questionnaires rating their perceived value of quality measures in evaluating a pharmacy (1 being low value and 5 being high) or choosing a pharmacy (yes/no). Thematic analysis and descriptive statistics were used to analyse the focus groups and surveys, respectively. Setting Semistructured focus groups were conducted in a private meeting space of an urban and a rural area of a Mid-western State in the USA. Participants Thirty-four adults who filled prescription medications in community pharmacies for a chronic illness were recruited in community pharmacies, senior centres and public libraries. Results While comments indicated that all measures were important, medication safety measures (eg, drug-drug interactions) were valued more highly than others. Rating of quality measure utility in evaluating a pharmacy ranged from a mean of 4.88 (‘drug-drug interactions’) to a mean of 4.0 (‘absence of controller therapy for patients with asthma’). Patients were hesitant to use quality information in choosing a pharmacy (depending on the participant's location) but might consider if moving to a new area or having had a negative pharmacy experience. Use of select quality measures to choose a pharmacy ranged from 97.1% of participants using ‘drug-drug interactions’ (medication safety measure) to 55.9% using ‘absence of controller therapy for patients with asthma’. Conclusions The study participants valued quality measures in evaluating and selecting a community pharmacy, with medication safety measures valued highest. The participants reported that the quality measures would not typically cause a switch in pharmacy but might influence their selection in certain situations. PMID:25600253

  17. Relative indexes of cutaneous blood perfusion measured by real-time laser Doppler imaging (LDI) in healthy volunteers.

    PubMed

    Seyed Jafari, S Morteza; Schawkat, Megir; Van De Ville, Dimitri; Shafighi, Maziar

    2014-07-01

    We used real-time LDI to study regional variations in microcirculatory perfusion in healthy candidates to establish a new methodology for global perfusion body mapping that is based on intra-individual perfusion index ratios. Our study included 74 (37 female) healthy volunteers aged between 22 and 30 years (mean 24.49). Imaging was performed using a recent microcirculation-imaging camera (EasyLDI) for different body regions of each volunteer. The perfusion values were reported in Arbitrary Perfusion Units (APU). The relative perfusion indexes for each candidate's body region were then obtained by normalization with the perfusion value of the forehead. Basic parameters such as weight, height, and blood pressure were also measured and analyzed. The highest mean perfusion value was reported in the forehead area (259.21APU). Mean perfusion in the measured parts of the body correlated positively with mean forehead value, while there was no significant correlation between forehead blood perfusion values and room temperature, BMI, systolic blood pressure and diastolic blood pressure (p=0.420, 0.623, 0.488, 0.099, respectively). Analysis of the data showed that perfusion indexes were not significantly different between male and female volunteers except for the ventral upper arm area (p=.001). LDI is a non-invasive, fast technique that opens several avenues for clinical applications. The mean perfusion indexes are useful in clinical practice for monitoring patients before and after surgical interventions. Perfusion values can be predicted for different body parts for patients only by taking the forehead perfusion value and using the perfusion index ratios to obtain expected normative perfusion values. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Initial NIST AC QHR Measurements

    PubMed Central

    Cage, M. E.; Shields, S. H.; Jeffery, A.

    2004-01-01

    We demonstrate that dc quantized Hall resistance (dc QHR) guideline properties and dc and ac QHR values can be measured without changing sample probe lead connections at the QHR device, and report ac QHR values that converge to the dc QHR value when using four-terminal-pair ac QHR measurements. This was accomplished during one cooldown using single-series and quadruple-series connections outside the sample probe. The QHR was measured from 0 Hz to 5500 Hz in 1:1 ratio at 20 µA to ±1 part in 107 uncertainties with a poor-quality QHR device. A good device would allow an order of magnitude smaller uncertainties over this frequency range. We exchanged positions of the QHR device and reference resistor in the bridge and remeasured the resistance ratios to remove dominant ac bridge effects. PMID:27366620

  19. Measuring the glycemic index of foods: interlaboratory study.

    PubMed

    Wolever, Thomas M S; Brand-Miller, Jennie C; Abernethy, John; Astrup, Arne; Atkinson, Fiona; Axelsen, Mette; Björck, Inger; Brighenti, Furio; Brown, Rachel; Brynes, Audrey; Casiraghi, M Cristina; Cazaubiel, Murielle; Dahlqvist, Linda; Delport, Elizabeth; Denyer, Gareth S; Erba, Daniela; Frost, Gary; Granfeldt, Yvonne; Hampton, Shelagh; Hart, Valerie A; Hätönen, Katja A; Henry, C Jeya; Hertzler, Steve; Hull, Sarah; Jerling, Johann; Johnston, Kelly L; Lightowler, Helen; Mann, Neil; Morgan, Linda; Panlasigui, Leonora N; Pelkman, Christine; Perry, Tracy; Pfeiffer, Andreas F H; Pieters, Marlien; Ramdath, D Dan; Ramsingh, Rayna T; Robert, S Daniel; Robinson, Carol; Sarkkinen, Essi; Scazzina, Francesca; Sison, Dave Clark D; Sloth, Birgitte; Staniforth, Jane; Tapola, Niina; Valsta, Liisa M; Verkooijen, Inge; Weickert, Martin O; Weseler, Antje R; Wilkie, Paul; Zhang, Jian

    2008-01-01

    Many laboratories offer glycemic index (GI) services. We assessed the performance of the method used to measure GI. The GI of cheese-puffs and fruit-leather (centrally provided) was measured in 28 laboratories (n=311 subjects) by using the FAO/WHO method. The laboratories reported the results of their calculations and sent the raw data for recalculation centrally. Values for the incremental area under the curve (AUC) reported by 54% of the laboratories differed from central calculations. Because of this and other differences in data analysis, 19% of reported food GI values differed by >5 units from those calculated centrally. GI values in individual subjects were unrelated to age, sex, ethnicity, body mass index, or AUC but were negatively related to within-individual variation (P=0.033) expressed as the CV of the AUC for repeated reference food tests (refCV). The between-laboratory GI values (mean+/-SD) for cheese-puffs and fruit-leather were 74.3+/-10.5 and 33.2+/-7.2, respectively. The mean laboratory GI was related to refCV (P=0.003) and the type of restrictions on alcohol consumption before the test (P=0.006, r2=0.509 for model). The within-laboratory SD of GI was related to refCV (P<0.001), the glucose analysis method (P=0.010), whether glucose measures were duplicated (P=0.008), and restrictions on dinner the night before (P=0.013, r2=0.810 for model). The between-laboratory SD of the GI values is approximately 9. Standardized data analysis and low within-subject variation (refCV<30%) are required for accuracy. The results suggest that common misconceptions exist about which factors do and do not need to be controlled to improve precision. Controlled studies and cost-benefit analyses are needed to optimize GI methodology. The trial was registered at clinicaltrials.gov as NCT00260858.

  20. Quality, Safety, Value: From Theory to Practice Management What Should We Measure?

    PubMed

    Shore, Benjamin J; Murphy, Robert F; Hogue, Grant D

    2015-01-01

    Over the past 35 years the health care community and in particular orthopaedic surgery, has undergone a transformation from retrospective case-series-based expert opinion to randomized prospective clinical trials. During this transition, orthopaedic surgeons have become very skilled in the measurement of physician-derived outcomes (radiographic angles, complications, recurrences, and mortality); however, these are not patient-centered outcomes and they are of little importance to our patients' satisfaction. Moving forward outcome measurement needs to be restructured to focus more on patient-reported outcomes. This paper outlines why outcome measurement is important, reviews outcome strategies that have been used historically, introduces a new outcome measurement tool and identifies strategies for future implementation and measurement of health care quality and value within pediatric orthopaedics.

  1. Do Health Care Delivery System Reforms Improve Value? The Jury Is Still Out.

    PubMed

    Korenstein, Deborah; Duan, Kevin; Diaz, Manuel J; Ahn, Rosa; Keyhani, Salomeh

    2016-01-01

    Widespread restructuring of health delivery systems is underway in the United States to reduce costs and improve the quality of health care. To describe studies evaluating the impact of system-level interventions (incentives and delivery structures) on the value of US health care, defined as the balance between quality and cost. We identified articles in PubMed (2003 to July 2014) using keywords identified through an iterative process, with reference and author tracking. We searched tables of contents of relevant journals from August 2014 through 11 August 2015 to update our sample. We included prospective or retrospective studies of system-level changes, with a control, reporting both quality and either cost or utilization of resources. Data about study design, study quality, and outcomes was extracted by one reviewer and checked by a second. Thirty reports of 28 interventions were included. Interventions included patient-centered medical home implementations (n=12), pay-for-performance programs (n=10), and mixed interventions (n=6); no other intervention types were identified. Most reports (n=19) described both cost and utilization outcomes. Quality, cost, and utilization outcomes varied widely; many improvements were small and process outcomes predominated. Improved value (improved quality with stable or lower cost/utilization or stable quality with lower cost/utilization) was seen in 23 reports; 1 showed decreased value, and 6 showed unchanged, unclear, or mixed results.Study limitations included variability among specific endpoints reported, inconsistent methodologies, and lack of full adjustment in some observational trials. Lack of standardized MeSH terms was also a challenge in the search. On balance, the literature suggests that health system reforms can improve value. However, this finding is tempered by the varying outcomes evaluated across studies with little documented improvement in outcome quality measures. Standardized measures of value would facilitate assessment of the impact of interventions across studies and better estimates of the broad impact of system change.

  2. A high deuterium abundance at redshift z = 0.7.

    PubMed

    Webb, J K; Carswell, R F; Lanzetta, K M; Ferlet, R; Lemoine, M; Vidal-Madjar, A; Bowen, D V

    1997-07-17

    Of the light elements, the primordial abundance of deuterium relative to hydrogen, (D/H)p, provides the most sensitive diagnostic for the cosmological mass density parameter, omegaB. Recent high-redshift D/H measurements are highly discrepant, although this may reflect observational uncertainties. The larger primordial D/H values imply a low omegaB (requiring the Universe to be dominated by non-baryonic matter), and cause problems for galactic chemical evolution models, which have difficulty in reproducing the steep decline in D/H to the present-day values. Conversely, the lower D/H values measured at high redshift imply an omegaB greater than that derived from 7Li and 4He abundance measurements, and may require a deuterium-abundance evolution that is too low to easily explain. Here we report the first measurement of D/H at intermediate redshift (z = 0.7010), in a gas cloud selected to minimize observational uncertainties. Our analysis yields a value of D/H ((2.0 +/- 0.5) x 10[-4]) which is at the upper end of the range of values measured at high redshifts. This finding, together with other independent observations, suggests that there may be inhomogeneity in (D/H)p of at least a factor of ten.

  3. Automated extraction of ejection fraction for quality measurement using regular expressions in Unstructured Information Management Architecture (UIMA) for heart failure

    PubMed Central

    DuVall, Scott L; South, Brett R; Bray, Bruce E; Bolton, Daniel; Heavirland, Julia; Pickard, Steve; Heidenreich, Paul; Shen, Shuying; Weir, Charlene; Samore, Matthew; Goldstein, Mary K

    2012-01-01

    Objectives Left ventricular ejection fraction (EF) is a key component of heart failure quality measures used within the Department of Veteran Affairs (VA). Our goals were to build a natural language processing system to extract the EF from free-text echocardiogram reports to automate measurement reporting and to validate the accuracy of the system using a comparison reference standard developed through human review. This project was a Translational Use Case Project within the VA Consortium for Healthcare Informatics. Materials and methods We created a set of regular expressions and rules to capture the EF using a random sample of 765 echocardiograms from seven VA medical centers. The documents were randomly assigned to two sets: a set of 275 used for training and a second set of 490 used for testing and validation. To establish the reference standard, two independent reviewers annotated all documents in both sets; a third reviewer adjudicated disagreements. Results System test results for document-level classification of EF of <40% had a sensitivity (recall) of 98.41%, a specificity of 100%, a positive predictive value (precision) of 100%, and an F measure of 99.2%. System test results at the concept level had a sensitivity of 88.9% (95% CI 87.7% to 90.0%), a positive predictive value of 95% (95% CI 94.2% to 95.9%), and an F measure of 91.9% (95% CI 91.2% to 92.7%). Discussion An EF value of <40% can be accurately identified in VA echocardiogram reports. Conclusions An automated information extraction system can be used to accurately extract EF for quality measurement. PMID:22437073

  4. Performance Indicators in Spine Surgery.

    PubMed

    St-Pierre, Godefroy Hardy; Yang, Michael H; Bourget-Murray, Jonathan; Thomas, Ken C; Hurlbert, Robin John; Matthes, Nikolas

    2018-02-15

    Systematic review. To elucidate how performance indicators are currently used in spine surgery. The Patient Protection and Affordable Care Act has given significant traction to the idea that healthcare must provide value to the patient through the introduction of hospital value-based purchasing. The key to implementing this new paradigm is to measure this value notably through performance indicators. MEDLINE, CINAHL Plus, EMBASE, and Google Scholar were searched for studies reporting the use of performance indicators specific to spine surgery. We followed the Prisma-P methodology for a systematic review for entries from January 1980 to July 2016. All full text articles were then reviewed to identify any measure of performance published within the article. This measure was then examined as per the three criteria of established standard, exclusion/risk adjustment, and benchmarking to determine if it constituted a performance indicator. The initial search yielded 85 results among which two relevant studies were identified. The extended search gave a total of 865 citations across databases among which 15 new articles were identified. The grey literature search provided five additional reports which in turn led to six additional articles. A total of 27 full text articles and reports were retrieved and reviewed. We were unable to identify performance indicators. The articles presenting a measure of performance were organized based on how many criteria they lacked. We further examined the next steps to be taken to craft the first performance indicator in spine surgery. The science of performance measurement applied to spine surgery is still in its infancy. Current outcome metrics used in clinical settings require refinement to become performance indicators. Current registry work is providing the necessary foundation, but requires benchmarking to truly measure performance. 1.

  5. What's the agreement between self-reported and biochemical verification of drug use? A look at permanent supportive housing residents.

    PubMed

    Rendon, Alexis; Livingston, Melvin; Suzuki, Sumihiro; Hill, Whitney; Walters, Scott

    2017-07-01

    Self-reported substance use is commonly used as an outcome measure in treatment research. We evaluated the validity of self-reported drug use in a sample of 334 adults with mental health problems who were residing in supportive housing programs. The primary analysis was the calculation of the positive predictive values (PPVs) of self-report compared to an oral fluid test taken at the same time. A sensitivity analysis compared the positive predictive values of two self-reported drug use histories: biological testing window (ranging between the past 96h to 30days depending on drug type) or the full past 90-day comparison window (maximum length recorded during interview). A multivariable logistic regression was used to predict discordance between self-report and the drug test for users. Self-reported drug use and oral fluid drug tests were compared to determine the positive predictive value for amphetamines/methamphetamines/PCP (47.1% agreement), cocaine (43.8% agreement), and marijuana (69.7% agreement) drug tests. Participants who misreported their drug use were more likely to be older, non-White, have no medical insurance, and not report any alcohol use. In general, amphetamine/methamphetamine/PCP and cocaine use was adequately captured by the biological test, while marijuana use was best captured by a combination of self-report and biological data. Using the full past 90day comparison window resulted in higher concordance with the oral fluid drug test, indicating that self-reported drug use in the past 90days may be a proxy for drug use within the biological testing window. Self-report has some disadvantages when used as the sole measure of drug use in this population. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. The influence of outdoor thermal environment on young Japanese females.

    PubMed

    Kurazumi, Yoshihito; Ishii, Jin; Kondo, Emi; Fukagawa, Kenta; Bolashikov, Zhecho Dimitrov; Sakoi, Tomonori; Tsuchikawa, Tadahiro; Matsubara, Naoki; Horikoshi, Tetsumi

    2014-07-01

    The influence of short wave solar radiation appears to be strong outdoors in summer, and the influence of airflow appears to be strong outdoors in winter. The purpose of this paper was to clarify the influence of the outdoor environment on young Japanese females. This research shows the relationship between the physiological and psychological responses of humans and the enhanced conduction-corrected modified effective temperature (ETFe). Subjective experiments were conducted in an outdoor environment. Subjects were exposed to the thermal environment in a standing posture. Air temperature, humidity, air velocity, short wave solar radiation, long wave radiation, ground surface temperature, sky factor, and the green solid angle were measured. The temperatures of skin exposed to the atmosphere and in contact with the ground were measured. Thermal sensation and thermal comfort were measured by means of rating the whole-body thermal sensation (cold-hot) and the whole body thermal comfort (comfortable-uncomfortable) on a linear scale. Linear rating scales are given for the hot (100) and cold (0), and comfortable (100) and uncomfortable (0) directions only. Arbitrary values of 0 and 100 were assigned to each endpoint, the reported values read in, and the entire length converted into a numerical value with an arbitrary scale of 100 to give a linear rating scale. The ETFe considered to report a neither hot nor cold, thermally neutral sensation of 50 was 35.9 °C, with 32.3 °C and 42.9 °C, respectively, corresponding to the low and high temperature ends of the ETFe considered to report a neither comfortable nor uncomfortable comfort value of 50. The mean skin temperature considered to report a neither hot nor cold, thermally neutral sensation of 50 was 33.3 °C, with 31.0 °C and 34.3 °C, respectively, corresponding to the low and high temperature ends of the mean skin temperature considered to report a neither comfortable nor uncomfortable comfort value of 50. The acceptability raised the mean skin temperature even for thermal environment conditions in which ETFe was high.

  7. The influence of outdoor thermal environment on young Japanese females

    NASA Astrophysics Data System (ADS)

    Kurazumi, Yoshihito; Ishii, Jin; Kondo, Emi; Fukagawa, Kenta; Bolashikov, Zhecho Dimitrov; Sakoi, Tomonori; Tsuchikawa, Tadahiro; Matsubara, Naoki; Horikoshi, Tetsumi

    2014-07-01

    The influence of short wave solar radiation appears to be strong outdoors in summer, and the influence of airflow appears to be strong outdoors in winter. The purpose of this paper was to clarify the influence of the outdoor environment on young Japanese females. This research shows the relationship between the physiological and psychological responses of humans and the enhanced conduction-corrected modified effective temperature (ETFe). Subjective experiments were conducted in an outdoor environment. Subjects were exposed to the thermal environment in a standing posture. Air temperature, humidity, air velocity, short wave solar radiation, long wave radiation, ground surface temperature, sky factor, and the green solid angle were measured. The temperatures of skin exposed to the atmosphere and in contact with the ground were measured. Thermal sensation and thermal comfort were measured by means of rating the whole-body thermal sensation (cold-hot) and the whole body thermal comfort (comfortable-uncomfortable) on a linear scale. Linear rating scales are given for the hot (100) and cold (0), and comfortable (100) and uncomfortable (0) directions only. Arbitrary values of 0 and 100 were assigned to each endpoint, the reported values read in, and the entire length converted into a numerical value with an arbitrary scale of 100 to give a linear rating scale. The ETFe considered to report a neither hot nor cold, thermally neutral sensation of 50 was 35.9 °C, with 32.3 °C and 42.9 °C, respectively, corresponding to the low and high temperature ends of the ETFe considered to report a neither comfortable nor uncomfortable comfort value of 50. The mean skin temperature considered to report a neither hot nor cold, thermally neutral sensation of 50 was 33.3 °C, with 31.0 °C and 34.3 °C, respectively, corresponding to the low and high temperature ends of the mean skin temperature considered to report a neither comfortable nor uncomfortable comfort value of 50. The acceptability raised the mean skin temperature even for thermal environment conditions in which ETFe was high.

  8. Magnetic field penetration in niobium- and vanadium-based Josephson junctions

    NASA Astrophysics Data System (ADS)

    Cucolo, A. M.; Pace, S.; Vaglio, R.; di Chiara, A.; Peluso, G.; Russo, M.

    1983-02-01

    Measurements on the temperature dependence of the magnetic field penetration in Nb-NbxOy-Pb and V-VxOy-Pb Josephson junctions have been performed. Results on the zero-temperature penetration depth in niobium films are far above the bulk values although consistent with other measurements on junctions reported in the literature. For vanadium junctions anomalously large penetration depth values are obtained at low temperatures. Nevertheless, the temperature dependence is in reasonable agreement with the local dirty limit model.

  9. Composite space charge density functions for the calculation of gamma sensitivity of self-powered neutron detectors, using Warren's model

    NASA Astrophysics Data System (ADS)

    Mahant, A. K.; Rao, P. S.; Misra, S. C.

    1994-07-01

    In the calculational model developed by Warren and Shah for the computation of the gamma sensitivity ( Sγ) it has been observed that the computed Sγ value is quite sensitive to the space charge distribution function assumed for the insulator region and the energy of the gamma photons. The Sγ of SPNDs with Pt, Co and V emitters (manufactured by Thermocoax, France) has been measured at 60Co photon energy and a good correlation between the measured and computed values has been obtained using a composite space charge density function (CSCD), the details of which are presented in this paper. The arguments are extended for evaluating the Sγ values of several SPNDs for which Warren and Shah reported the measured values for a prompt fission gamma spectrum obtained in a swimming pool reactor. These results are also discussed.

  10. Measuring the value of nonwage employee benefits: building a model of the relation between benefit satisfaction and value.

    PubMed

    Weathington, Bart L; Jones, Allan P

    2006-11-01

    Researchers have commonly assumed benefits that employees view as more valuable have a greater influence on their attitudes and behaviors. Researchers have used 2 common methods to measure benefit value: attaching a monetary value to benefits and using self-reports of benefit importance. The present authors propose that the 2 approaches are conceptually distinct and have different implications. They use a social exchange perspective to justify this distinction and integrate both approaches and benefit satisfaction into a more comprehensive model of benefit perception. Results suggest that both measures have practical applications depending on the nature of the exchange relationship between the organization and employees. However, this relationship depends on the specific benefit and on employee satisfaction with that benefit. Some benefits lend themselves to a monetary estimate, whereas others lend themselves more to a nonmonetary valuation.

  11. Small Aircraft RF Interference Path Loss Measurements

    NASA Technical Reports Server (NTRS)

    Nguyen, Truong X.; Koppen, Sandra V.; Ely, Jay J.; Szatkowski, George N.; Mielnik, John J.; Salud, Maria Theresa P.

    2007-01-01

    Interference to aircraft radio receivers is an increasing concern as more portable electronic devices are allowed onboard. Interference signals are attenuated as they propagate from inside the cabin to aircraft radio antennas mounted on the outside of the aircraft. The attenuation level is referred to as the interference path loss (IPL) value. Significant published IPL data exists for transport and regional category airplanes. This report fills a void by providing data for small business/corporate and general aviation aircraft. In this effort, IPL measurements are performed on ten small aircraft of different designs and manufacturers. Multiple radio systems are addressed. Along with the typical worst-case coupling values, statistical distributions are also reported that could lead to more meaningful interference risk assessment.

  12. Evaluation of Biomonitoring Data from the CDC National ...

    EPA Pesticide Factsheets

    BACKGROUND: Biomonitoring data reported in the National Report on Human Exposure to Environmental Chemicals (NER) provide information on the presence and concentrations of more than 400 chemicals in human blood and urine. Biomonitoring Equivalents (BEs) and other risk assessment-based values now allow interpretation of these biomonitoring data in a public health risk context. OBJECTIVES: Compare the measured biomarker concentrations in the NER with BEs and similar risk assessment values to provide an across-chemical risk assessment perspective on the measured levels for approximately 130 analytes in the NER. METHODS: Available risk assessment-based biomarker screening values, including BEs and Human Biomonitoring-I (HBM-I) values from the German Human Biomonitoring Commission, were identified. Geometric mean and 95th percentile population biomarker concentrations from the NER were compared to the available screening values to generate chemical-specific hazard quotients (HQ) or cancer risk estimates. CONCLUSIONS: Several analytes in the NER approach or exceed HQ values of 1 or cancer risks greater than 1x 10-4 at the geometric mean or 95th percentile, suggesting exposure levels exceed what is considered safe in a large fraction of the population. Analytes of concern include acrylamide, dioxin-like chemicals, benzene, xylene, several metals, di-2(ethylhexyl)phthalate, and some legacy organochlorine pesticides. This analysis provides for the first time a mean

  13. Accuracy of Self-Reported Weight among Adolescent and Young Adults Following Bariatric Surgery

    PubMed Central

    Jenkins, Todd M.; Boyce, Tawny W.; Buncher, C. Ralph; Zeller, Meg H.; Courcoulas, Anita P.; Evans, Mary; Inge, Thomas H.

    2017-01-01

    Purpose This study evaluates accuracy of self-reported weight in adolescent bariatric surgery patients. Materials and Methods During follow-up visits, participants self-reported weight and had weight measured. Differences between self-reported and measured weights were analyzed from 60 participants. Results Participants were 70% (n=42) female, 72% (n=43) white, mean age of 20.8 years and median body mass index of 36.6 kg/m2. At an average 3.5 years following surgery, females underestimated weight (0.5kg, range: −18.7 to 5.6kg), while males overestimated (1.1kg, range: −7.8 to 15.2kg). Most (80%, n=48) reported within 5kg of measured weight. The majority of adolescents who previously underwent bariatric surgery reported reasonably accurate weights, but direction of misreporting varied by gender. Conclusion Self-reported weights could be utilized when measured values are unavailable without markedly biasing the interpretation of outcomes. PMID:28012151

  14. Deriving and Constraining 3D CME Kinematic Parameters from Multi-Viewpoint Coronagraph Images

    NASA Astrophysics Data System (ADS)

    Thompson, B. J.; Mei, H. F.; Barnes, D.; Colaninno, R. C.; Kwon, R.; Mays, M. L.; Mierla, M.; Moestl, C.; Richardson, I. G.; Verbeke, C.

    2017-12-01

    Determining the 3D properties of a coronal mass ejection using multi-viewpoint coronagraph observations can be a tremendously complicated process. There are many factors that inhibit the ability to unambiguously identify the speed, direction and shape of a CME. These factors include the need to separate the "true" CME mass from shock-associated brightenings, distinguish between non-radial or deflected trajectories, and identify asymmetric CME structures. Additionally, different measurement methods can produce different results, sometimes with great variations. Part of the reason for the wide range of values that can be reported for a single CME is due to the difficulty in determining the CME's longitude since uncertainty in the angle of the CME relative to the observing image planes results in errors in the speed and topology of the CME. Often the errors quoted in an individual study are remarkably small when compared to the range of values that are reported by different authors for the same CME. For example, two authors may report speeds of 700 +- 50 km/sec and 500+-50 km/sec for the same CME. Clearly a better understanding of the accuracy of CME measurements, and an improved assessment of the limitations of the different methods, would be of benefit. We report on a survey of CME measurements, wherein we compare the values reported by different authors and catalogs. The survey will allow us to establish typical errors for the parameters that are commonly used as inputs for CME propagation models such as ENLIL and EUHFORIA. One way modelers handle inaccuracies in CME parameters is to use an ensemble of CMEs, sampled across ranges of latitude, longitude, speed and width. The CMEs simulated in order to determine the probability of a "direct hit" and, for the cases with a "hit," derive a range of possible arrival times. Our study will provide improved guidelines for generating CME ensembles that more accurately sample across the range of plausible values.

  15. Travelers’ Value of Time and Reliability as Measured on Katy Freeway : Final Report.

    DOT National Transportation Integrated Search

    2016-09-01

    The value of travel time savings (VOT) is an estimate of what travelers would be willing to pay in order to save time on a particular trip. If travelers would pay $1 to reduce their travel time by six minutes, then they have a VOT of $10 per hour. VO...

  16. Innovating for quality and value: Utilizing national quality improvement programs to identify opportunities for responsible surgical innovation.

    PubMed

    Woo, Russell K; Skarsgard, Erik D

    2015-06-01

    Innovation in surgical techniques, technology, and care processes are essential for improving the care and outcomes of surgical patients, including children. The time and cost associated with surgical innovation can be significant, and unless it leads to improvements in outcome at equivalent or lower costs, it adds little or no value from the perspective of the patients, and decreases the overall resources available to our already financially constrained healthcare system. The emergence of a safety and quality mandate in surgery, and the development of the American College of Surgeons National Surgical Quality Improvement Program (NSQIP) allow needs-based surgical care innovation which leads to value-based improvement in care. In addition to general and procedure-specific clinical outcomes, surgeons should consider the measurement of quality from the patients' perspective. To this end, the integration of validated Patient Reported Outcome Measures (PROMs) into actionable, benchmarked institutional outcomes reporting has the potential to facilitate quality improvement in process, treatment and technology that optimizes value for our patients and health system. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Hypertension and blood pressure awareness among American Indians of the northern plains.

    PubMed

    Sharlin, K S; Heath, G W; Ford, E S; Welty, T K

    1993-01-01

    This study compared self-reported and measured blood pressure among American Indians of the northern plains. In 1986, a group of American Indians from the northern plains was administered the Centers for Disease Control Behavioral Risk Factor Survey (which included a question about previous blood pressure measurements) and a health risk appraisal (which included blood pressure measurement). Approximately 18% of the respondents reported being told by a doctor, nurse, or other health professional that they had high blood pressure, and 11% actually had measured blood pressures of at least 140/90 mm Hg. Overall, only 50% of hypertensive participants correctly identified themselves as hypertensive (sensitivity); specificity was 92%, predictive value positive was 43%, predictive value negative was 94%, and efficiency (the proportion of individuals who correctly classified their blood pressure status as high or normal) was 87%. These findings agree with similar studies of hypertension awareness, and they indicate that lack of this awareness remains a significant problem in the fight against cardiovascular diseases and premature death among American Indians.

  18. Fiber-based modulated optical reflectance configuration allowing for offset pump and probe beams

    NASA Astrophysics Data System (ADS)

    Fleming, A.; Folsom, C.; Jensen, C.; Ban, H.

    2016-12-01

    A new fiber-based modulated optical reflectance configuration is developed in this work. The technique maintains the fiber-based heating laser (pump) and detection laser (probe) in close proximity at a fixed separation distance in a ceramic ferrule. The pump beam periodically heats the sample inducing thermal waves into the sample. The probe beam measures the temperature response at a known distance from the pump beam over a range of heating modulation frequencies. The thermal diffusivity of the sample may be calculated from the phase response between the input heat flux and the temperature response of a sample having a reflective surface. The unique measurement configuration is ideal for in situ measurements and has many advantages for laboratory-based systems. The design and development of the system are reported along with theoretical justification for the experimental design. The thermal diffusivities of Ge and SiC are measured and found to be within 10% of reported literature values. The diffusivity for SiO2 is measured with a relative difference of approximately 100% from the literature value when the ferrule is in contact with the sample. An additional measurement was made on the SiO2 sample with the ferrule not in contact resulting in a difference of less than 2% from the literature value. The difference in the SiO2 measurement when the ferrule is in contact with the sample is likely due to a parallel heat transfer path through the dual-fiber ferrule assembly.

  19. Fiber-based modulated optical reflectance configuration allowing for offset pump and probe beams.

    PubMed

    Fleming, A; Folsom, C; Jensen, C; Ban, H

    2016-12-01

    A new fiber-based modulated optical reflectance configuration is developed in this work. The technique maintains the fiber-based heating laser (pump) and detection laser (probe) in close proximity at a fixed separation distance in a ceramic ferrule. The pump beam periodically heats the sample inducing thermal waves into the sample. The probe beam measures the temperature response at a known distance from the pump beam over a range of heating modulation frequencies. The thermal diffusivity of the sample may be calculated from the phase response between the input heat flux and the temperature response of a sample having a reflective surface. The unique measurement configuration is ideal for in situ measurements and has many advantages for laboratory-based systems. The design and development of the system are reported along with theoretical justification for the experimental design. The thermal diffusivities of Ge and SiC are measured and found to be within 10% of reported literature values. The diffusivity for SiO 2 is measured with a relative difference of approximately 100% from the literature value when the ferrule is in contact with the sample. An additional measurement was made on the SiO 2 sample with the ferrule not in contact resulting in a difference of less than 2% from the literature value. The difference in the SiO 2 measurement when the ferrule is in contact with the sample is likely due to a parallel heat transfer path through the dual-fiber ferrule assembly.

  20. The prognostic value of kidney transplant center report cards.

    PubMed

    Schold, J D; Buccini, L D; Heaphy, E L G; Goldfarb, D A; Sehgal, A R; Fung, J; Poggio, E D; Kattan, M W

    2013-07-01

    SRTR report cards provide the basis for quality measurement of US transplant centers. There is limited data evaluating the prognostic value of report cards, informing whether they are predictive of prospective patient outcomes. Using national SRTR data, we simulated report cards and calculated standardized mortality ratios (SMR) for kidney transplant centers over five distinct eras. We ranked centers based on SMR and evaluated outcomes for patients transplanted the year following reports. Recipients transplanted at the 50th, 100th and 200th ranked centers had 18% (AHR = 1.18, 1.13-1.22), 38% (AHR = 1.38, 1.28-1.49) and 91% (AHR = 1.91, 1.64-2.21) increased hazard for 1-year mortality relative to recipients at the top-ranked center. Risks were attenuated but remained significant for long-term outcomes. Patients transplanted at centers meeting low-performance criteria in the prior period had 40% (AHR = 1.40, 1.22-1.68) elevated hazard for 1-year mortality in the prospective period. Centers' SMR from the report card was highly predictive (c-statistics > 0.77) for prospective center SMRs and there was significant correlation between centers' SMR from the report card period and the year following (ρ = 0.57, p < 0.001). Although results do not mitigate potential biases of report cards for measuring quality, they do indicate strong prognostic value for future outcomes. Findings also highlight that outcomes are associated with center ranking across a continuum rather than solely at performance margins. © Copyright 2013 The American Society of Transplantation and the American Society of Transplant Surgeons.

  1. Automated Visibility Measurements with a Horizon Scanning Imager. Volume 1. Technical Discussion

    DTIC Science & Technology

    1990-12-01

    environment, if one difficult. In the case of many relatively simplistic "rule assumes that the measured values of Cr are consistently following...report unless contractual obligations or notices on a specific document requires that it be returned. REPORT DOCUMENTATION PAGE Approved OMB No. 0704-0188...control computer from the original Zenith Z-248 incentive being that the sooner one identifies the class desktop to the Texas Micro Systems (TMI) design

  2. Development of a Brief Self-Report Measure of Work-Related Cognitive Limitations in Breast Cancer Survivors

    DTIC Science & Technology

    2013-01-08

    measure of sampling adequacy, the Kaiser - Meyer - Olkin (KMO) value ( Kaiser , 1970, 1974), was .76 for randomized group 1 (n = 114) and .72 for...Wefel, Lenzi, Theriault, Davis, & Meyers , 2004). Cognitive Challenges in the Context of Work Cognitive demands are required in many different types...Shilling et al., 2005; Wefel et al., 2004; Wefel, Saleeba, Buzdar, & Meyers , 2010). However, cognitive limitations observed and reported can depend on

  3. Report on the Photometric Observations of the Variable Stars DH Pegasi, DY Pegasi, and RZ Cephei

    NASA Astrophysics Data System (ADS)

    Abu-Sharkh, I.; Fang, S.; Mehta, S.; Pham, D.

    2014-12-01

    We report 872 observations on two RR Lyrae variable stars, DH Pegasi and RZ Cephei, and on one SX Phoenicis variable, DY Pegasi. This paper discusses the methodology of our measurements, the light curves, magnitudes, epochs, and epoch prediction of the above stars. We also derived the period of DY Pegasi. All measurements and analyses are compared with prior publications and known values from multiple databases.

  4. Turbofan aft duct suppressor study. Contractor's data report of mode probe signal data

    NASA Technical Reports Server (NTRS)

    Fiske, G. H.; Motsinger, R. E.; Syed, A. A.; Joshi, M. C.; Kraft, R. E.

    1983-01-01

    Acoustic modal distributions were measured in a fan test model having an annular exhaust duct for comparison with theoretically predicted acoustic suppression values. This report contains the amplitude and phase data of the acoustic signals sensed by the transducers of the two mode probes employed in the measurement. Each mode probe consisted of an array of 12 transducers sensing the acoustic field at three axial positions and four radial positions.

  5. Patient value: its nature, measurement, and role in real world evidence studies and outcomes-based reimbursement.

    PubMed

    McKenna, Stephen P; Wilburn, Jeanette

    2018-05-01

    The assessment of "patient value" is fundamental to clinical trials, real world evidence studies, and outcomes-based reimbursement schemes. Measures of health-related quality-of-life (HRQoL) are widely used in health research. Such measures are effective in determining the presence or absence of symptoms and functional ability. However, HRQoL measures were not intended, nor designed, to determine the value to patients of alternative health states. Functions have no intrinsic value-they are a means to fulfil human needs. However, needs can be met in a variety of ways, for example by adopting different functions or by the provision of social services. It is possible to analyze all functions in terms of the needs they satisfy. A needs model has been applied in health research since the 1990s. It is concerned with the extent to which human needs are fulfilled in the presence of disease and its treatment. It is argued that this is the major concern of the patient. Needs-based measures are patient-centric and produce a valid unidimensional index of outcome. Consequently, they provide a direct means of measuring patient value. This approach provides the possibility of evaluating health services in terms of the value they provide to consumers and payers. It also has a role to play in real-world evidence studies and outcomes-based reimbursement. It is recommended that greater attention is given in future to the development of patient-reported outcome measures that provide direct assessments of patient value.

  6. Emissions of Glyoxal and Other Carbonyl Compounds from Agricultural Biomass Burning Plumes Sampled by Aircraft.

    PubMed

    Zarzana, Kyle J; Min, Kyung-Eun; Washenfelder, Rebecca A; Kaiser, Jennifer; Krawiec-Thayer, Mitchell; Peischl, Jeff; Neuman, J Andrew; Nowak, John B; Wagner, Nicholas L; Dubè, William P; St Clair, Jason M; Wolfe, Glenn M; Hanisco, Thomas F; Keutsch, Frank N; Ryerson, Thomas B; Brown, Steven S

    2017-10-17

    We report enhancements of glyoxal and methylglyoxal relative to carbon monoxide and formaldehyde in agricultural biomass burning plumes intercepted by the NOAA WP-3D aircraft during the 2013 Southeast Nexus and 2015 Shale Oil and Natural Gas Nexus campaigns. Glyoxal and methylglyoxal were measured using broadband cavity enhanced spectroscopy, which for glyoxal provides a highly selective and sensitive measurement. While enhancement ratios of other species such as methane and formaldehyde were consistent with previous measurements, glyoxal enhancements relative to carbon monoxide averaged 0.0016 ± 0.0009, a factor of 4 lower than values used in global models. Glyoxal enhancements relative to formaldehyde were 30 times lower than previously reported, averaging 0.038 ± 0.02. Several glyoxal loss processes such as photolysis, reactions with hydroxyl radicals, and aerosol uptake were found to be insufficient to explain the lower measured values of glyoxal relative to other biomass burning trace gases, indicating that glyoxal emissions from agricultural biomass burning may be significantly overestimated. Methylglyoxal enhancements were three to six times higher than reported in other recent studies, but spectral interferences from other substituted dicarbyonyls introduce an estimated correction factor of 2 and at least a 25% uncertainty, such that accurate measurements of the enhancements are difficult.

  7. Implementation of a closed-loop reporting system for critical values and clinical communication in compliance with goals of the joint commission.

    PubMed

    Parl, Fritz F; O'Leary, Mandy F; Kaiser, Allen B; Paulett, John M; Statnikova, Kristina; Shultz, Edward K

    2010-03-01

    Current practices of reporting critical laboratory values make it challenging to measure and assess the timeliness of receipt by the treating physician as required by The Joint Commission's 2008 National Patient Safety Goals. A multidisciplinary team of laboratorians, clinicians, and information technology experts developed an electronic ALERTS system that reports critical values via the laboratory and hospital information systems to alphanumeric pagers of clinicians and ensures failsafe notification, instant documentation, automatic tracking, escalation, and reporting of critical value alerts. A method for automated acknowledgment of message receipt was incorporated into the system design. The ALERTS system has been applied to inpatients and eliminated approximately 9000 phone calls a year made by medical technologists. Although a small number of phone calls were still made as a result of pages not acknowledged by clinicians within 10 min, they were made by telephone operators, who either contacted the same physician who was initially paged by the automated system or identified and contacted alternate physicians or the patient's nurse. Overall, documentation of physician acknowledgment of receipt in the electronic medical record increased to 95% of critical values over 9 months, while the median time decreased to <3 min. We improved laboratory efficiency and physician communication by developing an electronic system for reporting of critical values that is in compliance with The Joint Commission's goals.

  8. Hyperventilation in anticipatory music performance anxiety.

    PubMed

    Studer, Regina Katharina; Danuser, Brigitta; Hildebrandt, Horst; Arial, Marc; Wild, Pascal; Gomez, Patrick

    2012-09-01

    Self-report studies have shown an association between music performance anxiety (MPA) and hyperventilation complaints. However, hyperventilation was never assessed physiologically in MPA. This study investigated the self-reported affective experience, self-reported physiological symptoms, and cardiorespiratory variables including partial pressure of end-tidal CO(2) (Petco(2)), which is an indicator for hyperventilation, in 67 music students before a private and a public performance. The response coherence between these response domains was also investigated. From the private to the public session, the intensity of all self-report variables increased (all p values < .001). As predicted, the higher the musician's usual MPA level, the larger were these increases (p values < .10). With the exception of Petco(2), the main cardiorespiratory variables also increased from the private to the public session (p values < .05). These increases were not modulated by the usual MPA level (p values > .10). Petco(2) showed a unique response pattern reflected by an MPA-by-session interaction (p < .01): it increased from the private to the public session for musicians with low MPA levels and decreased for musicians with high MPA levels. Self-reported physiological symptoms were related to the self-reported affective experience (p values < .05) rather than to physiological measures (p values > .17). These findings show for the first time how respiration is stimulated before a public performance in music students with different MPA levels. The hypothesis of a hyperventilation tendency in high-performance-anxious musicians is supported. The response coherence between physiological symptoms and physiological activation is weak.

  9. Adherence to outpatient epilepsy quality indicators at a tertiary epilepsy center.

    PubMed

    Pourdeyhimi, R; Wolf, B J; Simpson, A N; Martz, G U

    2014-10-01

    Quality indicators for the treatment of people with epilepsy were published in 2010. This is the first report of adherence to all measures in routine care of people with epilepsy at a level 4 comprehensive epilepsy center in the US. Two hundred patients with epilepsy were randomly selected from the clinics of our comprehensive epilepsy center, and all visits during 2011 were abstracted for documentation of adherence to the eight quality indicators. Alternative measures were constructed to evaluate failure of adherence. Detailed descriptions of all equations are provided. Objective measures (EEG, imaging) showed higher adherence than counseling measures (safety). Initial visits showed higher adherence. Variations in the interpretation of the quality measure result in different adherence values. Advanced practice providers and physicians had different adherence patterns. No patient-specific patterns of adherence were seen. This is the first report of adherence to all the epilepsy quality indicators for a sample of patients during routine care in a level 4 epilepsy center in the US. Overall adherence was similar to that previously reported on similar measures. Precise definitions of adherence equations are essential for accurate measurement. Complex measures result in lower adherence. Counseling measures showed low adherence, possibly highlighting a difference between practice and documentation. Adherence to the measures as written does not guarantee high quality care. The current quality indicators have value in the process of improving quality of care. Future approaches may be refined to eliminate complex measures and incorporate features linked to outcomes. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Use of the Cygnus GlucoWatch biographer at a diabetes camp.

    PubMed

    Gandrud, Laura M; Paguntalan, Helen U; Van Wyhe, M Michelle; Kunselman, Betsy L; Leptien, Amy D; Wilson, Darrell M; Eastman, Richard C; Buckingham, Bruce A

    2004-01-01

    Detection and prevention of nocturnal hypoglycemia is a major medical concern at diabetes camps. We conducted an open-label trial of the Cygnus GlucoWatch biographer to detect nocturnal hypoglycemia in a diabetes camp, a nonclinical environment with multiple activities. Forty-five campers (7-17 years old) wore a biographer. The biographer was placed on the arm at 6:00 PM, with the low alarm set to 85 mg/dL (4.7 mmol/L). Overnight glucose monitoring occurred per usual camp protocol. Counselors were to check and record blood glucose values if the biographer alarmed. Biographers were worn for 154 nights by 45 campers. After a 3-hour warm-up period, 67% of biographers were calibrated, of which 28% were worn the entire night (12 hours). Thirty-four percent of readings were skipped because of: "data errors" (65%), sweat (20%), and temperature change (16%). Reported biographer values correlated with meter glucose values measured 11 to 20 minutes later (r = 0.90). Of 20 low-glucose alarms with corresponding meter values measured within 20 minutes, there were 10 true-positive alarms, 10 false-positive alarms, and no false-negative alarms. Campers reported sleep disruption 32% of the nights, and 74% found the biographer helpful. Campers reported they would wear the biographer 4 to 5 nights each week. Half of the biographer low-glucose alarms that had corresponding blood meter values were true-positive alarms, and the remaining were false-positive alarms. There was close correlation between the biographer and meter glucose values. The majority of campers found the biographer helpful and would use it at home.

  11. Assessment of Iodine-treated Filter Media for Removal and Inactivation of MS2 Bacteriophase Aerosols

    DTIC Science & Technology

    2009-04-01

    values measured for test filters. The PRE was measured for ultrafine particles (i.e., 9.82 to 162.5 nm), whereas the VRE was measured over the entire...than that of ultrafine particles . This effect was observed in a prior study (Hogan et al. 2005), which reported that the possibility of containing

  12. A Health Economics Approach to US Value Assessment Frameworks-Summary and Recommendations of the ISPOR Special Task Force Report [7].

    PubMed

    Garrison, Louis P; Neumann, Peter J; Willke, Richard J; Basu, Anirban; Danzon, Patricia M; Doshi, Jalpa A; Drummond, Michael F; Lakdawalla, Darius N; Pauly, Mark V; Phelps, Charles E; Ramsey, Scott D; Towse, Adrian; Weinstein, Milton C

    2018-02-01

    This summary section first lists key points from each of the six sections of the report, followed by six key recommendations. The Special Task Force chose to take a health economics approach to the question of whether a health plan should cover and reimburse a specific technology, beginning with the view that the conventional cost-per-quality-adjusted life-year metric has both strengths as a starting point and recognized limitations. This report calls for the development of a more comprehensive economic evaluation that could include novel elements of value (e.g., insurance value and equity) as part of either an "augmented" cost-effectiveness analysis or a multicriteria decision analysis. Given an aggregation of elements to a measure of value, consistent use of a cost-effectiveness threshold can help ensure the maximization of health gain and well-being for a given budget. These decisions can benefit from the use of deliberative processes. The six recommendations are to: 1) be explicit about decision context and perspective in value assessment frameworks; 2) base health plan coverage and reimbursement decisions on an evaluation of the incremental costs and benefits of health care technologies as is provided by cost-effectiveness analysis; 3) develop value thresholds to serve as one important input to help guide coverage and reimbursement decisions; 4) manage budget constraints and affordability on the basis of cost-effectiveness principles; 5) test and consider using structured deliberative processes for health plan coverage and reimbursement decisions; and 6) explore and test novel elements of benefit to improve value measures that reflect the perspectives of both plan members and patients. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  13. Napping Characteristics and Restricted Participation in Valued Activities Among Older Adults.

    PubMed

    Owusu, Jocelynn T; Ramsey, Christine M; Tzuang, Marian; Kaufmann, Christopher N; Parisi, Jeanine M; Spira, Adam P

    2018-03-02

    Napping is associated with both positive and negative health outcomes among older adults. However, the association between particular napping characteristics (eg, frequency, duration, and whether naps were intentional) and daytime function is unclear. Participants were 2,739 community-dwelling Medicare beneficiaries aged ≥65 years from the nationally representative National Health and Aging Trends Study. Participants reported napping frequency, duration, and whether naps were intentional versus unintentional. Restricted participation in valued activities was measured by self-report. After adjusting for potential confounders and nighttime sleep duration, those who took intentional and unintentional naps had a greater odds of any valued activity restriction (ie, ≥1 valued activity restriction), compared to those who rarely/never napped (unintentional odds ratio [OR] = 1.34, 95% confidence interval [CI] 1.01, 1.79, intentional OR = 1.49, 95% CI 1.09, 2.04). There was no difference between unintentional napping and intentional napping with respect to any valued activity restriction after adjustment for demographics. Compared to participants napping "some days," those napping most days/every day had a greater odds of any valued activity restriction (OR = 1.68, 95% CI 1.30, 2.16). Moreover, each 30-minute increase in average nap duration was associated with a 25% greater odds of any valued activity restriction (OR = 1.25, 95% CI 1.10, 1.43). Older adults who took more frequent or longer naps were more likely to report activity restrictions, as were those who took intentional or unintentional naps. Additional longitudinal studies with objective measures of sleep are needed to further our understanding of associations between napping characteristics and daytime dysfunction. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. Activation energy of extracellular enzymes in soils from different biomes.

    PubMed

    Steinweg, J Megan; Jagadamma, Sindhu; Frerichs, Joshua; Mayes, Melanie A

    2013-01-01

    Enzyme dynamics are being incorporated into soil carbon cycling models and accurate representation of enzyme kinetics is an important step in predicting belowground nutrient dynamics. A scarce number of studies have measured activation energy (Ea) in soils and fewer studies have measured Ea in arctic and tropical soils, or in subsurface soils. We determined the Ea for four typical lignocellulose degrading enzymes in the A and B horizons of seven soils covering six different soil orders. We also elucidated which soil properties predicted any measurable differences in Ea. β-glucosidase, cellobiohydrolase, phenol oxidase and peroxidase activities were measured at five temperatures, 4, 21, 30, 40, and 60°C. Ea was calculated using the Arrhenius equation. β-glucosidase and cellobiohydrolase Ea values for both A and B horizons in this study were similar to previously reported values, however we could not make a direct comparison for B horizon soils because of the lack of data. There was no consistent relationship between hydrolase enzyme Ea and the environmental variables we measured. Phenol oxidase was the only enzyme that had a consistent positive relationship between Ea and pH in both horizons. The Ea in the arctic and subarctic zones for peroxidase was lower than the hydrolases and phenol oxidase values, indicating peroxidase may be a rate limited enzyme in environments under warming conditions. By including these six soil types we have increased the number of soil oxidative enzyme Ea values reported in the literature by 50%. This study is a step towards better quantifying enzyme kinetics in different climate zones.

  15. Three common misuses of P values

    PubMed Central

    Kim, Jeehyoung; Bang, Heejung

    2016-01-01

    “Significance” has a specific meaning in science, especially in statistics. The p-value as a measure of statistical significance (evidence against a null hypothesis) has long been used in statistical inference and has served as a key player in science and research. Despite its clear mathematical definition and original purpose, and being just one of the many statistical measures/criteria, its role has been over-emphasized along with hypothesis testing. Observing and reflecting on this practice, some journals have attempted to ban reporting of p-values, and the American Statistical Association (for the first time in its 177 year old history) released a statement on p-values in 2016. In this article, we intend to review the correct definition of the p-value as well as its common misuses, in the hope that our article is useful to clinicians and researchers. PMID:27695640

  16. Congruence and functions of personal and cultural values: do my values reflect my culture's values?

    PubMed

    Fischer, Ronald

    2006-11-01

    Two studies are described examining the correlation between self- and culture-referenced values at a culture level (Study 1) and correlation between self- and culture-referenced values and self-reported behavior at an individual level (Study 2). It is found that values related to individual-group relationships (embeddedness) and expression and experience of affective feelings and emotions (affective autonomy) are significantly correlated at a culture level. In Study 2, culture-referenced values are shown to correlate with behaviors attached to social norms, whereas self-rated values are found to correlate with behaviors that are not norm-governed. Implications for measurement of cultural values and cultural and cross-cultural research designs are discussed.

  17. Values and preferences of women living with HIV who are pregnant, postpartum or considering pregnancy on choice of antiretroviral therapy during pregnancy.

    PubMed

    Lytvyn, Lyubov; Siemieniuk, Reed A; Dilmitis, Sophie; Ion, Allyson; Chang, Yaping; Bala, Malgorzata M; Manja, Veena; Mirza, Reza; Rodriguez-Gutierrez, Rene; Mir, Hassan; El Dib, Regina; Banfield, Laura; Vandvik, Per Olav; Bewley, Susan

    2017-09-11

    To investigate women's values and preferences regarding antiretroviral therapy (ART) during pregnancy to inform a BMJ Rapid Recommendation. Primary studies reporting patient-reported outcomes relevant to decision-making regarding ART in any clinical and geographical setting. Women living with HIV who are pregnant, postpartum or considering pregnancy. Quantitative measurements and qualitative descriptions of values and preferences in relation to ART during pregnancy. We also included studies on women's reported barriers and facilitators to adherence. We excluded studies correlating objective measures (eg, CD4 count) with adherence, or reporting only outcomes which are not expected to differ between ART alternatives (eg, access to services, knowledge about ART). We included 15 qualitative studies reporting values and preferences about ART in the peripartum period; no study directly studied choice of ART therapy during pregnancy. Six themes emerged: a desire to reduce vertical transmission (nine studies), desire for child to be healthy (five studies), concern about side effects to the child (eight studies), desire for oneself to be healthy (five studies), distress about side effect to oneself (10 studies) and pill burden (two studies). None of the studies weighed the relative importance of these outcomes directly, but pill burden/medication complexity appears to be a lower priority for most women compared with other factors. Overall, the body of evidence was at low risk of bias, with minor limitations. Women who are or may become pregnant and who are considering ART appear to place a high value on both their own and their children's health. Evidence on the relative importance between these values when choosing between ART regimens is uncertain. There is variability in individual values and preferences among women. This highlights the importance of an individualised women-centred approach, such as shared decision-making when choosing between ART alternatives. International Prospective Register of Systematic Reviews:CRD42017057157. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Improving Recreational Water Quality Assessments Through Novel Approaches to Quantifying Measurement Uncertainty

    EPA Science Inventory

    Bacteriological water quality in the Great Lakes is typically measured by the concentration of fecal indicator bacteria (FIB), and is reported via most probable number (MPN) or colony forming unit (CFU) values derived from algorithms relating \\raw data" in a FIB analysis procedu...

  19. New Measurement of the 60Fe Half-Life.

    PubMed

    Rugel, G; Faestermann, T; Knie, K; Korschinek, G; Poutivtsev, M; Schumann, D; Kivel, N; Günther-Leopold, I; Weinreich, R; Wohlmuther, M

    2009-08-14

    We have made a new determination of the half-life of the radioactive isotope 60Fe using high precision measurements of the number of 60Fe atoms and their activity in a sample containing over 10(15) 60Fe atoms. Our new value for the half-life of 60Fe is (2.62+/-0.04) x 10(6) yr, significantly above the previously reported value of (1.49+/-0.27) x 10(6) yr. Our new measurement for the lifetime of 60Fe has significant implications for interpretations of galactic nucleosynthesis, for determinations of formation time scales of solids in the early Solar System, and for the interpretation of live 60Fe measurements from supernova-ejecta deposits on Earth.

  20. International comparison of activity measurements of a solution of 75Se

    NASA Astrophysics Data System (ADS)

    Ratel, Guy

    2002-04-01

    Activity measurements of a solution of 75Se, supplied by the BIPM, have been carried out by 21 laboratories within the framework of an international comparison. Seven different methods were used. Details on source preparation, experimental facilities and counting data are reported. The measured activity-concentration values show a total spread of 6.62% before correction and 6.02% after correction for delayed events, with standard deviations of the unweighted means of 0.45% and 0.36%, respectively. The correction for delayed events was measured directly by four laboratories. Unfortunately no consensus on the activity value could be deduced from their results. The results of the comparison have been entered in the tables of the International Reference System (SIR) for γ-ray emitting radionuclides. The half-life of the metastable state was also determined by two laboratories and found to be in good agreement with the values found in the literature.

  1. Montreal Accord on Patient-Reported Outcomes (PROs) use series-Paper 7: modern perspectives of measurement validation emphasize justification of inferences based on patient reported outcome scores.

    PubMed

    Sawatzky, Richard; Chan, Eric K H; Zumbo, Bruno D; Ahmed, Sara; Bartlett, Susan J; Bingham, Clifton O; Gardner, William; Jutai, Jeffrey; Kuspinar, Ayse; Sajobi, Tolulope; Lix, Lisa M

    2017-09-01

    Obtaining the patient's view about the outcome of care is an essential component of patient-centered care. Many patient-reported outcome (PRO) instruments for different purposes have been developed since the 1960s. Measurement validation is fundamental in the development, evaluation, and use of PRO instruments. This paper provides a review of modern perspectives of measurement validation in relation to the followings three questions as applied to PROs: (1) What evidence is needed to warrant comparisons between groups and individuals? (2) What evidence is needed to warrant comparisons over time? and (3) What are the value implications, including personal and societal consequences, of using PRO scores? Measurement validation is an ongoing process that involves the accumulation of evidence regarding the justification of inferences, actions, and decisions based on measurement scores. These include inferences pertaining to comparisons between groups and comparisons over time as well as consideration of value implications of using PRO scores. Personal and societal consequences must be examined as part of a comprehensive approach to measurement validation. The answers to these three questions are fundamental to the the validity of different types of inferences, actions, and decisions made on PRO scores in health research, health care administration, and clinical practice. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Assay Dilution Factors Confound Measures of Total Antioxidant Capacity in Polyphenol-Rich Juices

    PubMed Central

    Bolling, Bradley W.; Chen, Ya-Yen; Kamil, Alison G.; Chen, C-Y. Oliver

    2016-01-01

    The extent to which sample dilution factor (DF) affects total antioxidant capacity (TAC) values is poorly understood. Thus, we examined the impact of DF on the ORAC, FRAP, DPPH, and total phenols (TP) assays using pomegranate juice (PJ), grape juice (GJ), selected flavonoids, ascorbic acid, and ellagic acid. For ORAC, GJ was comparable to PJ at DF 750, but at DF 2000, the ORAC value of GJ was 40% more than PJ. Increasing DF increased GJ and PJ, DPPH, TP, and FRAP values 11% and 14%, respectively. Increased test concentrations of quercetin and catechin resulted in 51% and 126% greater ORAC values, but decreased naringenin by 68%. Flavonoids, but not ellagic acid or ascorbic acid, may contribute to the dilution effect on the variation of final TAC values. Thus, reporting TAC or TP using a single DF may introduce uncertainty about the confidence of TAC assay values, especially when comparing different juices. These results underscore the importance of using compatible test standards for reporting TAC values. PMID:22251245

  3. An examination of the usefulness of repeat testing practices in a large hospital clinical chemistry laboratory.

    PubMed

    Deetz, Carl O; Nolan, Debra K; Scott, Mitchell G

    2012-01-01

    A long-standing practice in clinical laboratories has been to automatically repeat laboratory tests when values trigger automated "repeat rules" in the laboratory information system such as a critical test result. We examined 25,553 repeated laboratory values for 30 common chemistry tests from December 1, 2010, to February 28, 2011, to determine whether this practice is necessary and whether it may be possible to reduce repeat testing to improve efficiency and turnaround time for reporting critical values. An "error" was defined to occur when the difference between the initial and verified values exceeded the College of American Pathologists/Clinical Laboratory Improvement Amendments allowable error limit. The initial values from 2.6% of all repeated tests (668) were errors. Of these 668 errors, only 102 occurred for values within the analytic measurement range. Median delays in reporting critical values owing to repeated testing ranged from 5 (blood gases) to 17 (glucose) minutes.

  4. The Value of Medicines: A Crucial but Vague Concept.

    PubMed

    Antoñanzas, Fernando; Terkola, Robert; Postma, Maarten

    2016-12-01

    Health Technology Assessment is increasingly used to evaluate the value of healthcare products and to prioritize resources; however, defining exactly what value is and how it should be measured remains a challenge. In this article, we report the results of a literature review, focusing on nine European countries, with the aim of investigating how value is defined from the perspective of different stakeholders, how definitions of value are used, and how value is incorporated into decision making. Only three articles were identified that presented definitions of value, and there was no single shared definition of value in healthcare, which appears to be a highly subjective concept. The majority of the countries investigated combine clinical assessment with economic evaluation to make reimbursement recommendations; the quality-adjusted life-year is the most commonly used measure of value but does not capture broader aspects of value that may be important to patients and healthcare systems. We describe the use of value-based pricing and multi-criteria decision analysis, two approaches to the incorporation of broader aspects of value into decision making. Overall, we have identified considerable variation in how a product's value is defined by different stakeholders. Although a universal understanding of value in healthcare is important, it is clear that current definitions are insufficient, potentially leading to inconsistent reimbursement decisions. Ultimately, the establishment of clearer policies for defining and measuring value in healthcare is needed, and is likely to lead to improvements in the consistency of decision making.

  5. Shuttle swimming test in young water polo players: reliability, responsiveness and age-related value.

    PubMed

    Melchiorri, Giovanni; Viero, Valerio; Triossi, Tamara; Padua, Elvira; Bonifazi, Marco

    2017-11-01

    This study investigated the applicability of a sport-specific test, the Shuttle Swim Test, in young water polo players to measure RSA. The aims were: to assess the reliability and to measure the responsiveness of the SST in young water polo athletes, and to provide age-related values of SST. Three hundred thirty-three elite athletes (18.3±5.1 years) were involved in the study. Of these, 99 were young people under 13 (13.1±0.5 years) who also underwent measurements for reliability and responsiveness of the SST The following six measures was used to assess anthropometric characteristics of the sample: height, weight, chest circumference, hip circumference, waist circumference, and arm span. Two performance measures were performed on dry land: push up and chin up. Reliability and responsiveness were measured by comparing the average speed of two trials: SST1 was 1.48±0.13 m·s-1 and SST2 1.47±.12 m·s-1. The SST showed good reliability in younger athletes (r=0.96). The Minimal Detectable Change is 0.06 m·s-1 (6 seconds of the total time) which corresponds to 3.6% of the average value measured, confirming the good responsiveness of the test. Coaches and researchers can use this value in the interpretation of the SST test results: changes below these values could be related to a measurement error. The various age-related values reported may help technicians to better interpret the performance of their athletes during competition.

  6. Strategic Reporting Tool: Balanced Scorecards in Higher Education

    ERIC Educational Resources Information Center

    Lyddon, Jan W.; McComb, Bruce E.

    2008-01-01

    In this toolbox article, the authors describe the recommended steps for creating a community college balanced scorecard that measures and reports on key performance indicators based on targets and signal values to end-users, college constituents and external stakeholders. Based on extensive experience in the field, the authors provide a…

  7. A Core Curriculum for Tomorrow's Citizens

    ERIC Educational Resources Information Center

    Lewis, Harry R.

    2008-01-01

    Should the 21st-century university have a core curriculum? The report of the Secretary of Education's Commission on the Future of Higher Education said nothing about general education, the learning that educated Americans should share. Instead the Spellings commission report highlighted broad access and measurable "value added" as the major…

  8. A Core Curriculum for Tomorrow's Citizens

    ERIC Educational Resources Information Center

    Lewis, Harry R.

    2007-01-01

    Should the 21st-century university have a core curriculum? The report of the Secretary of Education's Commission on the Future of Higher Education said nothing about general education, the learning that educated Americans should share. Instead the Spellings commission report highlighted broad access and measurable "value added" as the major…

  9. Discordance between self-reported arthritis and musculoskeletal signs and symptoms in older women.

    PubMed

    Lo, Tkt; Parkinson, Lynne; Cunich, Michelle; Byles, Julie

    2016-12-01

    Arthritis is a gendered disease where women have a higher prevalence and more disability than men with arthritis of the same age. Health survey data is a major source of information for monitoring of the burden of arthritis. The validity of self-reported arthritis and the determinants of its accuracy among women have not been thoroughly studied. The objectives of this study were to: 1) examine the agreement between self-report diagnosed arthritis and musculoskeletal signs and symptoms in community-living older women; 2) estimate the sensitivity, specificity, and predictive values of self-reported arthritis; and 3) assess the factors associated with the disagreement. A cross-sectional survey of women was undertaken in 2012-13. The health survey asked women about diagnosed arthritis and musculoskeletal signs and symptoms. Agreement between self-reported arthritis and musculoskeletal signs symptoms was measured by Cohen's kappa. Sensitivity, specificity, and predictive values of self-reported arthritis were estimated using musculoskeletal signs and symptoms as the reference standard. Factors associated with disagreement between self-reported arthritis and the reference standard were examined using multiple logistic regression. There were 223 participants self-reported arthritis and 347 did not. A greater number of participants who self-reported arthritis were obese compared to those who did not report arthritis. Those who reported arthritis had worse health, physical functioning, and arthritis symptom measures. Among the 570 participants, 198 had musculoskeletal signs and symptoms suggesting arthritis (the reference standard). Agreement between self-reported arthritis and the reference standard was moderate (kappa = 0.41). Sensitivity, specificity, and positive and negative predictive values of self-reported arthritis in older women were 66.7, 75.5, 59.2, and 81.0% respectively. Regression analysis results indicated that false-positive is associated with better health measured by the Short Form 36 physical summary score, the Health Assessment Questionnaire disability index, or the Western Ontario and McMaster University Osteoarthritis Index total score; whereas false-negative is negatively associated with these variables. While some women who reported diagnosed arthritis did not have recent musculoskeletal signs or symptoms, others with the signs and symptoms did not report diagnosed arthritis. Researchers should use caution when employing self-reported arthritis as the case-definition in epidemiological studies.

  10. Water, ice, and meteorological measurements at South Cascade Glacier, Washington, 1986-1991 balance years

    USGS Publications Warehouse

    Krimmel, Robert M.

    2000-01-01

    Mass balance and climate variables are reported for South Cascade Glacier, Washington, for the years 1986-91. These variables include air temperature, precipitation, water runoff, snow accumulation, snow and ice melt terminus position, surface level, and ice speed. Data are reduced to daily and monthly values where appropriate. The glacier-averaged values of spring snow accumulation and fall net balance given in this report differ from previous results because amore complete analysis is made. Snow accumulation values for the1986-91 period ranged from 3.54 (water equivalent) meters in 1991 to2.04 meters in 1987. Net balance values ranged from 0.07 meters in1991 to -2.06 meters in 1987. The glacier became much smaller during the 1986-91 period and retreated a cumulative 50 meters.

  11. Do employers know the quality of health care benefits they provide? Use of HEDIS depression scores for health plans.

    PubMed

    Robst, John; Rost, Kathryn; Marshall, Donna

    2013-11-01

    OBJECTIVE Dissemination of health quality measures is a necessary ingredient of efforts to harness market-based forces, such as value-based purchasing by employers, to improve health care quality. This study examined reporting of Healthcare Effectiveness Data and Information Set (HEDIS) measures for depression to firms interested in improving depression care. METHODS During surveys conducted between 2009 and 2011, a sample of 325 employers that were interested in improving depression treatment were asked whether their primary health plan reports HEDIS scores for depression to the National Committee for Quality Assurance (NCQA) and if so, whether they knew the scores. Data about HEDIS reporting by the health plans were collected from the NCQA. RESULTS HEDIS depression scores were reported by the primary health plans of 154 (47%) employers, but only 7% of employers knew their plan's HEDIS scores. Because larger employers were more likely to report knowing the scores, 53% of all employees worked for employers who reported knowing the scores. A number of structural, health benefit, and need characteristics predicted knowledge of HEDIS depression scores by employers. CONCLUSIONS The study demonstrated that motivated employers did not know their depression HEDIS scores even when their plan publicly reported them. Measures of health care quality are not reaching the buyers of insurance products; however, larger employers were more likely to know the HEDIS scores for their health plan, suggesting that value-based purchasing may have some ability to affect health care quality.

  12. Significant changes in physical activity among pregnant women in the UK as assessed by accelerometry and self-reported activity.

    PubMed

    Rousham, E K; Clarke, P E; Gross, H

    2006-03-01

    Research on the impact of maternal physical activity on pregnancy outcomes has often employed subjective measures of physical activity obtained by diary or questionnaire. This study investigates the feasibility of using accelerometry as an objective measure of physical activity of pregnant women compared with subjective data obtained via activity recall among pregnant women. Activity data were collected prospectively on 57 women at 12, 16, 25, 34 and 38 weeks of gestation. Total daily physical activity was assessed by ambulatory accelerometer and activity interview (self-report). Maternal personality variables (health value, extroversion) were assessed by established scales. Leicestershire, UK. Pregnant women were recruited by voluntary participation via antenatal booking clinics. In all, 64 pregnant women with low-risk pregnancy were enrolled onto the study, of whom 57 completed the study. Mean 24 h physical activity levels (PAL) decreased significantly from second to third trimester as assessed by self-report interview (1.51-1.29 Metabolic Equivalent TEE-h/day, P<0.01) and accelerometry (200.05-147.42 counts/min, P<0.01). The correlation between the two measures declined as pregnancy progressed (r value ranging from 0.55 to 0.08). Compliance with the accelerometers declined from 90% at 12 weeks to 47% at 34 weeks (P<0.01). Compliance with the self-report interviews was 100%. Those who fully complied with the accelerometry demonstrated a significantly higher health value (P<0.05) and a significantly greater level of extroversion (P<0.05) than those who did not. Accelerometers and self-reported activity interviews both indicated a significant decline in PAL during pregnancy. Although subjects showed a willingness to use both methods, accelerometers resulted in variable compliance with 72 h monitoring. Both techniques may be limited by the need to measure low levels of physical activity during the third trimester. Cambridge Neurotechnology Ltd, UK, assisted with the provision of Actiwatch accelerometers.

  13. CALiPER Exploratory Study: Accounting for Uncertainty in Lumen Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bergman, Rolf; Paget, Maria L.; Richman, Eric E.

    2011-03-31

    With a well-defined and shared understanding of uncertainty in lumen measurements, testing laboratories can better evaluate their processes, contributing to greater consistency and credibility of lighting testing a key component of the U.S. Department of Energy (DOE) Commercially Available LED Product Evaluation and Reporting (CALiPER) program. Reliable lighting testing is a crucial underlying factor contributing toward the success of many energy-efficient lighting efforts, such as the DOE GATEWAY demonstrations, Lighting Facts Label, ENERGY STAR® energy efficient lighting programs, and many others. Uncertainty in measurements is inherent to all testing methodologies, including photometric and other lighting-related testing. Uncertainty exists for allmore » equipment, processes, and systems of measurement in individual as well as combined ways. A major issue with testing and the resulting accuracy of the tests is the uncertainty of the complete process. Individual equipment uncertainties are typically identified, but their relative value in practice and their combined value with other equipment and processes in the same test are elusive concepts, particularly for complex types of testing such as photometry. The total combined uncertainty of a measurement result is important for repeatable and comparative measurements for light emitting diode (LED) products in comparison with other technologies as well as competing products. This study provides a detailed and step-by-step method for determining uncertainty in lumen measurements, working closely with related standards efforts and key industry experts. This report uses the structure proposed in the Guide to Uncertainty Measurements (GUM) for evaluating and expressing uncertainty in measurements. The steps of the procedure are described and a spreadsheet format adapted for integrating sphere and goniophotometric uncertainty measurements is provided for entering parameters, ordering the information, calculating intermediate values and, finally, obtaining expanded uncertainties. Using this basis and examining each step of the photometric measurement and calibration methods, mathematical uncertainty models are developed. Determination of estimated values of input variables is discussed. Guidance is provided for the evaluation of the standard uncertainties of each input estimate, covariances associated with input estimates and the calculation of the result measurements. With this basis, the combined uncertainty of the measurement results and finally, the expanded uncertainty can be determined.« less

  14. Assessment of Adherence to Eating Habit and Exercise Components in a Behavioral Weight Control Program.

    ERIC Educational Resources Information Center

    Zegman, Marilyn A.

    Although the augmental value of exercise to behavioral weight control programs has been suggested, demonstration of this value is dependent upon an assessment of adherence to change in eating habits and activity patterns. Self-report measures of adherence were obtained from overweight college women undergoing treatment that involved either dietary…

  15. Bayesian Hypothesis Testing for Psychologists: A Tutorial on the Savage-Dickey Method

    ERIC Educational Resources Information Center

    Wagenmakers, Eric-Jan; Lodewyckx, Tom; Kuriyal, Himanshu; Grasman, Raoul

    2010-01-01

    In the field of cognitive psychology, the "p"-value hypothesis test has established a stranglehold on statistical reporting. This is unfortunate, as the "p"-value provides at best a rough estimate of the evidence that the data provide for the presence of an experimental effect. An alternative and arguably more appropriate measure of evidence is…

  16. A Multivariate Analysis of Personality, Values and Expectations as Correlates of Career Aspirations of Final Year Medical Students

    ERIC Educational Resources Information Center

    Rogers, Mary E.; Searle, Judy; Creed, Peter A.; Ng, Shu-Kay

    2010-01-01

    This study reports on the career intentions of 179 final year medical students who completed an online survey that included measures of personality, values, professional and lifestyle expectations, and well-being. Logistic regression analyses identified the determinants of preferred medical specialty, practice location and hours of work.…

  17. Result of International Round Robin Test on Young's Modulus Measurement of 304L and 316L Steels at Cryogenic Temperatures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shibata, K.; Ogata, T.; Nyilas, A.

    2006-03-31

    Ogata et al. reported in 1996 results of international Round Robin tests on mechanical property measurement of several metals at cryogenic temperatures. Following the report, the standard deviation of Young's modulus of 316L steel is much larger than those of yield and tensile strengths, that is, 4.6 % of the mean value for Young's modulus, while 1.4 % and 1.6 % of the mean values for yield and for tensile strengths, respectively. Therefore, an international Round Robin test on Young's modulus of two austenitic stainless steels at cryogenic temperatures under the participation often institutes from four nations has been initiatedmore » within these two years. As a result, the ratios of standard deviation to the mean values are 4.2 % for 304L and 3.6 % for 316L. Such a drop in the standard deviation is attributable to the decrease in the number of institute owing to the application of single extensometer or direct strain gage technique.« less

  18. Blood glucose measurement in patients with suspected diabetic ketoacidosis: a comparison of Abbott MediSense PCx point-of-care meter values to reference laboratory values.

    PubMed

    Blank, Fidela S J; Miller, Moses; Nichols, James; Smithline, Howard; Crabb, Gillian; Pekow, Penelope

    2009-04-01

    The purpose of this study is to compare blood glucose levels measured by a point of care (POC) device to laboratory measurement using the same sample venous blood from patients with suspected diabetic ketoacidosis (DKA). A descriptive correlational design was used for this IRB-approved quality assurance project. The study site was the 50-bed BMC emergency department (ED) which has an annual census of over 100,000 patient visits. The convenience sample consisted of 54 blood samples from suspected DKA patients with orders for hourly blood draws for glucose measurement. Spearman correlations of the glucose POC values, reference lab values, and differences between the two, were evaluated. A chi-square test was used to evaluate the association between the acidosis status and FDA acceptability of POC values. Patient age range was 10-86 years; 63% were females; 46% had a final diagnosis of DKA. POC values underestimated glucose levels 93% of the time. There was a high correlation between the lab value and the magnitude of the difference, (lab minus POC value) indicating that the higher the true glucose value, the greater the difference between the lab and the POC value. A chi-square test showed no overall association between acidosis and FDA-acceptability. The POC values underestimated lab reported glucose levels in 50 of 54 cases even with the use of same venous sample sent to the lab, which make it highly unreliable for use in monitoring suspected DKA patients.

  19. Volumes Learned: It Takes More Than Size to "Size Up" Pulmonary Lesions.

    PubMed

    Ma, Xiaonan; Siegelman, Jenifer; Paik, David S; Mulshine, James L; St Pierre, Samantha; Buckler, Andrew J

    2016-09-01

    This study aimed to review the current understanding and capabilities regarding use of imaging for noninvasive lesion characterization and its relationship to lung cancer screening and treatment. Our review of the state of the art was broken down into questions about the different lung cancer image phenotypes being characterized, the role of imaging and requirements for increasing its value with respect to increasing diagnostic confidence and quantitative assessment, and a review of the current capabilities with respect to those needs. The preponderance of the literature has so far been focused on the measurement of lesion size, with increasing contributions being made to determine the formal performance of scanners, measurement tools, and human operators in terms of bias and variability. Concurrently, an increasing number of investigators are reporting utility and predictive value of measures other than size, and sensitivity and specificity is being reported. Relatively little has been documented on quantitative measurement of non-size features with corresponding estimation of measurement performance and reproducibility. The weight of the evidence suggests characterization of pulmonary lesions built on quantitative measures adds value to the screening for, and treatment of, lung cancer. Advanced image analysis techniques may identify patterns or biomarkers not readily assessed by eye and may also facilitate management of multidimensional imaging data in such a way as to efficiently integrate it into the clinical workflow. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  20. "MONSTROUS MOONSHINE" and Physics

    NASA Astrophysics Data System (ADS)

    Pushkin, A. V.

    The report presents some results obtained by the author on the quantum gravitation theory. Algebraic structure of this theory proves to be related to the commutative nonassociative Griess algebra. The theory symmetry is the automorphism group of Griess algebra: "Monster" simple group. Knowledge of the theory symmetry allows to compute observed physical values in the `zero' approximation. The report presents such computed results for values {m_{p}}/{m_{c}} and α, for the latter the `zero' approximation accuracy, controlled by the theory, being one order of magnitude higher than the accuracy of modern measurements.

  1. Access to Effective Teaching for Disadvantaged Students: Executive Summary. NCEE 2014-4002

    ERIC Educational Resources Information Center

    Isenberg, Eric; Max, Jeffrey; Gleason, Philip; Potamites, Liz; Santillano, Robert; Hock, Heinrich; Hansen, Michael

    2013-01-01

    This report describes disadvantaged students' access to effective teaching in grades 4 through 8 in 29 diverse school districts, using value-added analysis to measure effective teaching. Recent federal initiatives emphasize measuring teacher effectiveness and ensuring that disadvantaged students have equal access to effective teachers. These…

  2. Surface refractivity measurements at NASA spacecraft tracking sites

    NASA Technical Reports Server (NTRS)

    Schmid, P. E.

    1972-01-01

    High-accuracy spacecraft tracking requires tropospheric modeling which is generally scaled by either estimated or measured values of surface refractivity. This report summarizes the results of a worldwide surface-refractivity test conducted in 1968 in support of the Apollo program. The results are directly applicable to all NASA radio-tracking systems.

  3. Comment on the International Atomic Energy Agency Report on the Advisory Group Meeting on Stable Isotope Reference Samples for Geochemical and Hydrological Investigation, Vienna, Austria, September 19-21, 1983

    USGS Publications Warehouse

    Coplen, T.B.; Friedman, Irving; O'Neil, J.R.

    1984-01-01

    According to U.S. Geological Survey records, a report prepared by R. Gonfiantini summarizing the findings and recommendations of the 1983 Advisory Group Meeting on Stable Isotope Reference Samples for Geochemical and Hydrologic Investigations held in Vienna does not accurately represent the consultants ' consensus on three important points. The consultants (1) recommended no value for the C02-H20 oxygen isotope fractionation factor, not the cited value of 1.04115, (2) adopted a value of 1.0309 rather than 1.03086 to relate the PDB and SMOW scales, and (3) adopted a firm 180 value of -2.20% for NBS-19 on the PDB scale rather than agreeing that this would be a tentative value subject to modification when more measurements in selected laboratories are available. (USGS)

  4. Quantity quotient reporting. A proposal for a standardized presentation of laboratory results.

    PubMed

    Haeckel, Rainer; Wosniok, Werner

    2009-01-01

    Laboratory results are reported in different units (despite international recommendations for SI units) together with different reference limits, of which several exist for many quantities. It is proposed to adopt the concept of the intelligence quotient and to report quantitative results as a quantity quotient (QQ) in laboratory medicine. This quotient is essentially the difference (measured result minus mean or mode value of the reference interval) divided by the observed biological variation CV(o). Thus, all quantities are reported in the same unit system with the same reference limits (for convenience shifted to e.g., 80-120). The critical difference can also be included in this standardization concept. In this way the information of reference intervals and the original result are integrated into one combined value, which has the same format for all quantities suited for quotient reporting (QR). The proposal of QR does not interfere with neither the current concepts of traceability, SI units or method standardization. This proposal represents a further step towards harmonization of reporting. It provides simple values which can be interpreted easily by physicians and their patients.

  5. AMCP Partnership Forum: Improving Quality, Value, and Outcomes with Patient-Reported Outcomes.

    PubMed

    2018-03-01

    Patient-reported outcomes (PROs), which provide a direct measure of a patient's health status or treatment preferences, represent a key component of the shift toward patient-centered health care. PROs can measure the state of a patient's disease-specific and overall health throughout the care continuum, enabling them to have a variety of uses for key health care stakeholders. Currently, PROs are used in drug development, aligning patient and clinician goals in care, quality-of-care measures, and coverage and reimbursement decisions. While there have been significant strides by key health care stakeholders to further the development and use of PROs, there are a number of challenges limiting more widespread use. In light of these current challenges and the potential for PROs to improve health care quality and value, on October 19, 2017, the Academy of Managed Care Pharmacy convened a forum of key stakeholders representing patients, payers, providers, government, and pharmaceutical companies to discuss and identify solutions to the current challenges and barriers to further use of PROs. These discussions informed the development of participants' ideal future state in which PROs maximize the goals of all health care stakeholders and the actionable steps required to make the future state a reality. While stakeholders shared unique perspectives throughout the forum, they had consensus on 2 overarching issues: the importance of PROs in defining value, improving patient care, and implementing value-based payment models and the need for strong organizational and operational systems to achieve optimal adoption and use. Participants identified several key challenges in PRO use and adoption: achieving a representative patient population, inclusion of PRO data in medication labels, the necessity for both standardized and customizable PROs, and operational and organizational barriers to collecting and analyzing PROs. To overcome these challenges, participants recommended that manufacturers should engage key stakeholders early and throughout the drug development process to ensure the most valid and representative PROs and patient populations will be included. To streamline the PRO collection process, participants suggested engaging pharmacists and other providers who may have more frequent interaction with patients. Participants also recommended that PRO collection and analysis should use common technology platforms, streamline components of clinician care to reduce workflow, and be integrated with claims data to provider payers a better understanding of patient health in real time. Finally, additional work should be done to develop patient-reported outcome measures that contain relevant measures for all healthcare stakeholders. While significant challenges remain in PRO development and adoption, participants agreed that greater use can only be achieved through collaboration and patient-centered care. The AMCP Partnership Forum titled "Improving Quality, Value, and Outcomes with Patient-Reported Outcomes" and the development of this proceedings report were supported by Amgen, Boehringer Ingelheim Pharmaceuticals, Genentech, GlaxoSmithKline, Novartis Pharmaceuticals, Novo Nordisk, Precision for Value, Premier, Sanofi, Takeda Pharmaceuticals USA, and Xcenda.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hubaud, Aude A.; Schroeder, David J.; Ingram, Brian J.

    The thermal expansion (TE) coefficients of the lithium-stable lithium-ion conducting garnet lithium lanthanum zirconium oxide (LLZ) and the effect of aluminum substitution were measured from room temperature up to 700 °C by a synchrotron-based X-ray diffraction. The typical TE value measured for the most reported composition (LLZ doped with 0.3 wt.% or 0.093 mol% aluminum) was 15.498 × 10-6 K-1, which is approximately twice the value reported for other garnet-type structures. As the Al(III) concentration has been observed to strongly affect the structure observed and the ionic conductivity, we also assessed its role on thermal expansion and noted only amore » small variation with increasing dopant concentration. The materials implications for using LLZ in a solid state battery are discussed.« less

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cassata, W. S.; Velsko, C. A.; Stoeffl, W.

    We determined fission yields of xenon ( 133mXe, 135Xe, 135mXe, 137Xe, 138Xe, and 139Xe) resulting from 14 MeV neutron induced fission of depleted uranium at the National Ignition Facility. Measurements begin approximately 20 s after shot time, and yields have been determined for nuclides with half-lives as short as tens of seconds. We determined the relative independent yields of 133mXe, 135Xe, and 135mXe to significantly higher precision than previously reported. The relative fission yields of all nuclides are statistically indistinguishable from values reported by England and Rider (ENDF-349. LA-UR-94-3106, 1994), with exception of the cumulative yield of 139Xe. Furthermore, considerablemore » differences exist between our measured yields and the JEFF-3.1 database values.« less

  8. Enthalpy of sublimation as measured using a silicon oscillator

    NASA Astrophysics Data System (ADS)

    Shakeel, Hamza; Pomeroy, J. M.

    In this study, we report the enthalpy of sublimation of common gases (nitrogen, oxygen, argon, carbon dioxide, neon, krypton, xenon, and water vapor) using a large area silicon oscillator with a sub-ng (~0.027 ng/cm2) mass sensitivity. The double paddle oscillator design enables high frequency stability (17 ppb) at cryogenic temperatures and provides a consistent technique for enthalpy measurements. The enthalpies of sublimation are derived from the rate of mass loss during programmed thermal desorption and are detected as a change in the resonance frequency of the self-tracking oscillator. These measured enthalpy values show excellent agreement with the accepted literature values.

  9. First results on the measurements of the proton beam polarization at internal target at Nuclotron1

    NASA Astrophysics Data System (ADS)

    Ladygin, V. P.; Gurchin, Yu V.; Isupov, A. Yu; Janek, M.; Khrenov, A. N.; Kurilkin, P. K.; Livanov, A. N.; Piyadin, S. M.; Reznikov, S. G.; Skhomenko, Ya T.; Terekhin, A. A.; Tishevsky, A. V.; Averyanov, A. V.; Bazylev, S. N.; Belov, A. S.; Butenko, A. V.; Chernykh, E. V.; Filatov, Yu N.; Fimushkin, V. V.; Krivenkov, D. O.; Kondratenko, A. M.; Kondratenko, M. A.; Kovalenko, A. D.; Slepnev, I. V.; Slepnev, V. M.; Shutov, A. V.; Sidorin, A. O.; Vnukov, I. E.; Volkov, V. S.

    2017-12-01

    The spin program at NICA using SPD and MPD requires high intensity polarized proton beam with high value of the beam polarization. First results on the measurements of the proton beam polarization performed at internal target at Nuclotron are reported. The polarization of the proton beam provided by new source of polarized ions has been measured at 500 MeV using quasielastic proton-proton scattering and DSS setup at internal target. The obtained value of the vertical polarization of ∼35% is consistent with the calculations taking into account the current magnetic optics of the Nuclotron injection line.

  10. Studies on unsteady pressure fields in the region of separating and reattaching flows

    NASA Astrophysics Data System (ADS)

    Govinda Ram, H. S.; Arakeri, V. H.

    1990-12-01

    Experimental studies on the measurement of pressure fields in the region of separating and reattaching flows behind several two-dimensional fore-bodies and one axisymmetric body are reported. In particular, extensive measurements of mean pressure, surface pressure fluctuation, and pressure fluctuation within the flow were made for a series of two-dimensional fore-body shapes consisting of triangular nose with varying included angle. The measurements from different bodies are compared and one of the important findings is that the maximum values of rms pressure fluctuation levels in the shear layer approaching reattachment are almost equal to the maximum value of the surface fluctuation levels.

  11. A hand-powered, portable, low-cost centrifuge for diagnosing anemia in low-resource settings.

    PubMed

    Brown, Jocelyn; Theis, Lauren; Kerr, Lila; Zakhidova, Nazima; O'Connor, Kelly; Uthman, Margaret; Oden, Z Maria; Richards-Kortum, Rebecca

    2011-08-01

    This report describes the development of a hand-powered centrifuge to determine hematocrit values in low-resource settings. A hand-powered centrifuge was constructed by using a salad spinner. Hematocrit values were measured by using the hand-powered device, and results were compared with those of a benchtop centrifuge. The packed cell volume (PCV) measured with the hand-powered device correlated linearly with results obtained with a benchtop centrifuge (r = 0.986, P < 0.001). The PCVs measured with the hand-powered centrifuge were consistently 1.14 times higher than those measured with the benchtop system. The 14% increase in PCV measured with the hand-powered centrifuge is caused by increased plasma trapped in the cell column. The reader card was adjusted to compensate for trapped plasma. A hand-powered centrifuge and calibrated reader card can be constructed for U.S. $35 and can accurately determine hematocrit values. It is suitable for use in low-resource settings because it is mechanically-powered, inexpensive, and accurate.

  12. A Hand-Powered, Portable, Low-Cost Centrifuge for Diagnosing Anemia in Low-Resource Settings

    PubMed Central

    Brown, Jocelyn; Theis, Lauren; Kerr, Lila; Zakhidova, Nazima; O'Connor, Kelly; Uthman, Margaret; Oden, Z. Maria; Richards-Kortum, Rebecca

    2011-01-01

    This report describes the development of a hand-powered centrifuge to determine hematocrit values in low-resource settings. A hand-powered centrifuge was constructed by using a salad spinner. Hematocrit values were measured by using the hand-powered device, and results were compared with those of a benchtop centrifuge. The packed cell volume (PCV) measured with the hand-powered device correlated linearly with results obtained with a benchtop centrifuge (r = 0.986, P < 0.001). The PCVs measured with the hand-powered centrifuge were consistently 1.14 times higher than those measured with the benchtop system. The 14% increase in PCV measured with the hand-powered centrifuge is caused by increased plasma trapped in the cell column. The reader card was adjusted to compensate for trapped plasma. A hand-powered centrifuge and calibrated reader card can be constructed for U.S. $35 and can accurately determine hematocrit values. It is suitable for use in low-resource settings because it is mechanically-powered, inexpensive, and accurate. PMID:21813855

  13. Electroencephalogram approximate entropy influenced by both age and sleep.

    PubMed

    Lee, Gerick M H; Fattinger, Sara; Mouthon, Anne-Laure; Noirhomme, Quentin; Huber, Reto

    2013-01-01

    The use of information-based measures to assess changes in conscious state is an increasingly popular topic. Though recent results have seemed to justify the merits of such methods, little has been done to investigate the applicability of such measures to children. For our work, we used the approximate entropy (ApEn), a measure previously shown to correlate with changes in conscious state when applied to the electroencephalogram (EEG), and sought to confirm whether previously reported trends in adult ApEn values across wake and sleep were present in children. Besides validating the prior findings that ApEn decreases from wake to sleep (including wake, rapid eye movement (REM) sleep, and non-REM sleep) in adults, we found that previously reported ApEn decreases across vigilance states in adults were also present in children (ApEn trends for both age groups: wake > REM sleep > non-REM sleep). When comparing ApEn values between age groups, adults had significantly larger ApEn values than children during wakefulness. After the application of an 8 Hz high-pass filter to the EEG signal, ApEn values were recalculated. The number of electrodes with significant vigilance state effects dropped from all 109 electrodes with the original 1 Hz filter to 1 electrode with the 8 Hz filter. The number of electrodes with significant age effects dropped from 10 to 4. Our results support the notion that ApEn can reliably distinguish between vigilance states, with low-frequency sleep-related oscillations implicated as the driver of changes between vigilance states. We suggest that the observed differences between adult and child ApEn values during wake may reflect differences in connectivity between age groups, a factor which may be important in the use of EEG to measure consciousness.

  14. Harmonisation of serum dihydrotestosterone analysis: establishment of an external quality assurance program.

    PubMed

    Greaves, Ronda F; Jolly, Lisa; Hartmann, Michaela F; Ho, Chung Shun; Kam, Richard K T; Joseph, John; Boyder, Conchita; Wudy, Stefan A

    2017-03-01

    Serum dihydrotestosterone (DHT) is an important analyte for the clinical assessment of disorders of sex development. It is also reportedly a difficult analyte to measure. Currently, there are significant gaps in the standardisation of this analyte, including no external quality assurance (EQA) program available worldwide to allow for peer review performance of DHT. We therefore proposed to establish a pilot EQA program for serum DHT. DHT was assessed in the 2015 Royal College of Pathologists of Australasia Quality Assurance Programs' Endocrine program material. The material's target (i.e. "true") values were established using a measurement procedure based on isotope dilution gas chromatography (GC) tandem mass spectrometry (MS/MS). DHT calibrator values were based on weighed values of pure DHT material (>97.5% purity) from Sigma. The allowable limits of performance (ALP) were established as ±0.1 up to 0.5 nmol/L and ±15% for targets >0.5 nmol/L. Target values for the six levels of RCPAQAP material for DHT ranged from 0.02 to 0.43 nmol/L (0.01-0.12 ng/mL). The material demonstrated linearity across the six levels. There were seven participating laboratories for this pilot study. Results of the liquid chromatography (LC) MS/MS methods were within the ALP; whereas the results from the immunoassay methods were consistently higher than the target values and outside the ALP. This report provides the first peer comparison of serum DHT measured by mass spectrometry (MS) and immunoassay laboratories. Establishment of this program provides one of the pillars to achieve method harmonisation. This supports accurate clinical decisions where DHT measurement is required.

  15. Repeatability, variability and reference values of pulsed wave Doppler echocardiographic measurements in healthy Saanen goats

    PubMed Central

    2012-01-01

    Background Pulsed wave (PW) Doppler echocardiography has become a routine non invasive cardiac diagnostic tool in most species. However, evaluation of intracardiac blood flow requires reference values, which are poorly documented in goats. The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy adult Saanen goats. Using a standardised PW Doppler echocardiographic protocol, 10 healthy adult unsedated female Saanen goats were investigated three times at one day intervals by the same observer. Mitral, tricuspid, aortic and pulmonary flows were measured from a right parasternal view, and mitral and aortic flows were also measured from a left parasternal view. The difference between left and right side measurements and the intra-observer inter-day repeatability were tested and then the reference values of PW Doppler echocardiographic parameters in healthy adult female Saanen goats were established. Results As documented in other species, all caprine PW Doppler parameters demonstrated a poor inter-day repeatability and a moderate variability. Tricuspid and pulmonary flows were best evaluated on the right side whereas mitral and aortic flows were best obtained on the left side, and reference values are reported for healthy adult Saanen goats. Conclusions PW Doppler echocardiography allows the measurement of intracardiac blood flow indices in goats. The reference values establishment will help interpreting these indices of cardiac function in clinical cardiac cases and developing animal models for human cardiology research. PMID:23067875

  16. Determination of plutonium isotopes (238Pu, 239Pu, 240Pu, 241Pu) in environmental samples using radiochemical separation combined with radiometric and mass spectrometric measurements.

    PubMed

    Xu, Yihong; Qiao, Jixin; Hou, Xiaolin; Pan, Shaoming; Roos, Per

    2014-02-01

    This paper reports an analytical method for the determination of plutonium isotopes ((238)Pu, (239)Pu, (240)Pu, (241)Pu) in environmental samples using anion exchange chromatography in combination with extraction chromatography for chemical separation of Pu. Both radiometric methods (liquid scintillation counting and alpha spectrometry) and inductively coupled plasma mass spectrometry (ICP-MS) were applied for the measurement of plutonium isotopes. The decontamination factors for uranium were significantly improved up to 7.5 × 10(5) for 20 g soil compared to the level reported in the literature, this is critical for the measurement of plutonium isotopes using mass spectrometric technique. Although the chemical yield of Pu in the entire procedure is about 55%, the analytical results of IAEA soil 6 and IAEA-367 in this work are in a good agreement with the values reported in the literature or reference values, revealing that the developed method for plutonium determination in environmental samples is reliable. The measurement results of (239+240)Pu by alpha spectrometry agreed very well with the sum of (239)Pu and (240)Pu measured by ICP-MS. ICP-MS can not only measure (239)Pu and (240)Pu separately but also (241)Pu. However, it is impossible to measure (238)Pu using ICP-MS in environmental samples even a decontamination factor as high as 10(6) for uranium was obtained by chemical separation. © 2013 Elsevier B.V. All rights reserved.

  17. On the emission coefficient of uranium plasmas.

    NASA Technical Reports Server (NTRS)

    Schneider, R. T.; Campbell, H. D.; Mack, J. M.

    1973-01-01

    The emission coefficient for uranium plasmas (temperature: 8000 K) was measured for the wavelength range from 1200 to 6000 A. The results were compared to theoretical calculations and other measurements. Reasonable agreement between theoretical predictions and our measurements was found in the region from 1200 to 2000 A. Although it was difficult to make absolute comparisons among the different reported measurements, considerable disagreement was found for the higher wavelength region. A short discussion regarding the overall comparisons is given, and final suggestions are made as to the most appropriate emission coefficient values to be used in future design calculations. The absorption coefficient for the same wavelength interval is also reported.

  18. Differences between the prevalence of obesity and weight exceded estimated according to reported or direct measurement in adult people of Valencian Region

    PubMed

    Jiménez-Talamantes, Raquel; Rizk Hernández, Jennifer; Quiles Izquierdo, Joan

    2017-02-01

    Introduction: The assessment of obesity in health surveys includes the study of the physical characteristics of human body. Anthropometrical dates can be obtained by measurement or by interview. According the method that we were used we can estimate different values for frequencies of this problem. Objectives: Measure the discrepancies of the frequency of obesity and overweight estimated with data of height and weight obtained by interview respect to those measured in a population survey. Methods: Cross-sectional survey of a sample of 1,153 adult subjects, where height and weight data reported and measured were compared by Pearson correlation. It was estimated the prevalence of obesity and overweight by two methods and we calculated the Kappa’s index, the sensitivity and specifi city for to define the predictive capacity of reported data. Results: The values of weight, height and BMI by declared and measured data presented a correlation of 0.96, 0.93 and 0.91, respectively. The prevalence of obesity was 16.4% with declared data and 23.3% for measured data (kappa = 0.68), sensitivity 63.2% and specifi city 97.9%. The prevalence of excess of weight was 51.4% with declared data and 61.1% for measured data (kappa = 0.73), sensitivity 81.3% and specificity 95.3%. These differences were statistically signifi cant. Conclusions: There is an underestimation of the prevalence of obesity and excess of weight in populations when anthropometric data were used but in good agreement and specificity was found when measured data are used.

  19. On the relationship between NMR-derived amide order parameters and protein backbone entropy changes

    PubMed Central

    Sharp, Kim A.; O’Brien, Evan; Kasinath, Vignesh; Wand, A. Joshua

    2015-01-01

    Molecular dynamics simulations are used to analyze the relationship between NMR-derived squared generalized order parameters of amide NH groups and backbone entropy. Amide order parameters (O2NH) are largely determined by the secondary structure and average values appear unrelated to the overall flexibility of the protein. However, analysis of the more flexible subset (O2NH < 0.8) shows that these report both on the local flexibility of the protein and on a different component of the conformational entropy than that reported by the side chain methyl axis order parameters, O2axis. A calibration curve for backbone entropy vs. O2NH is developed which accounts for both correlations between amide group motions of different residues, and correlations between backbone and side chain motions. This calibration curve can be used with experimental values of O2NH changes obtained by NMR relaxation measurements to extract backbone entropy changes, e.g. upon ligand binding. In conjunction with our previous calibration for side chain entropy derived from measured O2axis values this provides a prescription for determination of the total protein conformational entropy changes from NMR relaxation measurements. PMID:25739366

  20. On the relationship between NMR-derived amide order parameters and protein backbone entropy changes.

    PubMed

    Sharp, Kim A; O'Brien, Evan; Kasinath, Vignesh; Wand, A Joshua

    2015-05-01

    Molecular dynamics simulations are used to analyze the relationship between NMR-derived squared generalized order parameters of amide NH groups and backbone entropy. Amide order parameters (O(2) NH ) are largely determined by the secondary structure and average values appear unrelated to the overall flexibility of the protein. However, analysis of the more flexible subset (O(2) NH  < 0.8) shows that these report both on the local flexibility of the protein and on a different component of the conformational entropy than that reported by the side chain methyl axis order parameters, O(2) axis . A calibration curve for backbone entropy vs. O(2) NH is developed, which accounts for both correlations between amide group motions of different residues, and correlations between backbone and side chain motions. This calibration curve can be used with experimental values of O(2) NH changes obtained by NMR relaxation measurements to extract backbone entropy changes, for example, upon ligand binding. In conjunction with our previous calibration for side chain entropy derived from measured O(2) axis values this provides a prescription for determination of the total protein conformational entropy changes from NMR relaxation measurements. © 2015 Wiley Periodicals, Inc.

  1. Accurate Measurements of the Local Deuterium Abundance from HST Spectra

    NASA Technical Reports Server (NTRS)

    Linsky, Jeffrey L.

    1996-01-01

    An accurate measurement of the primordial value of D/H would provide a critical test of nucleosynthesis models for the early universe and the baryon density. I briefly summarize the ongoing HST observations of the interstellar H and D Lyman-alpha absorption for lines of sight to nearby stars and comment on recent reports of extragalactic D/H measurements.

  2. Reporting the national antimicrobial consumption in Danish pigs: influence of assigned daily dosage values and population measurement.

    PubMed

    Dupont, Nana; Fertner, Mette; Kristensen, Charlotte Sonne; Toft, Nils; Stege, Helle

    2016-05-03

    Transparent calculation methods are crucial when investigating trends in antimicrobial consumption over time and between populations. Until 2011, one single standardized method was applied when quantifying the Danish pig antimicrobial consumption with the unit "Animal Daily Dose" (ADD). However, two new methods for assigning values for ADDs have recently emerged, one implemented by DANMAP, responsible for publishing annual reports on antimicrobial consumption, and one by the Danish Veterinary and Food Administration (DVFA), responsible for the Yellow Card initiative. In addition to new ADD assignment methods, Denmark has also experienced a shift in the production pattern, towards a larger export of live pigs. The aims of this paper were to (1) describe previous and current ADD assignment methods used by the major Danish institutions and (2) to illustrate how ADD assignment method and choice of population and population measurement affect the calculated national antimicrobial consumption in pigs (2007-2013). The old VetStat ADD-values were based on SPCs in contrast to the new ADD-values, which were based on active compound, concentration and administration route. The new ADD-values stated by both DANMAP and DVFA were only identical for 48 % of antimicrobial products approved for use in pigs. From 2007 to 2013, the total number of ADDs per year increased by 9 % when using the new DVFA ADD-values, but decreased by 2 and 7 % when using the new DANMAP ADD-values or the old VetStat ADD-values, respectively. Through 2007 to 2013, the production of pigs increased from 26.1 million pigs per year with 18 % exported live to 28.7 million with 34 % exported live. In the same time span, the annual pig antimicrobial consumption increased by 22.2 %, when calculated using the new DVFA ADD-values and pigs slaughtered per year as population measurement (13.0 ADDs/pig/year to 15.9 ADDs/pig/year). However, when based on the old VetStat ADD values and pigs produced per year (including live export), a 10.9 % decrease was seen (10.6 ADDs/pig/year to 9.4 ADDs/pig/year). The findings of this paper clearly highlight that calculated national antimicrobial consumption is highly affected by chosen population measurement and the applied ADD-values.

  3. Whole brain C-arm computed tomography parenchymal blood volume measurements

    PubMed Central

    Byrne, James V

    2016-01-01

    Introduction C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) imaging in the neuro-interventional suite is a new technique for which detailed whole brain measurements have not been previously reported. This study aims to create a catalogue of PBV measurements for various anatomical regions encompassing the whole brain, using a three-dimensional volume-of-interest (3D-VOI) analysis. Methods We acquired and analysed 30 C-arm FDCT datasets from 26 patients with aneurysmal subarachnoid haemorrhage (SAH), as part of a prospective study comparing C-arm computed tomography (CT) PBV with magnetic resonance perfusion-weighted imaging (MR-PWI). We calculated the PBV values for various brain regions with an automated analysis, using 58 pre-defined atlas-based 3D-VOIs encompassing the whole brain. VOIs partially or completely overlapping regions of magnetic resonance diffusion weighted imaging (MR-DWI) abnormality or magnetic resonance cerebral blood flow (MR-CBF) asymmetry were excluded from the analysis. Results Of the 30 C-arm CT PBV datasets, 14 (54%; 12 patients) had areas of restricted diffusion, the majority of which were focal. The PBV values for the cerebral cortex and cerebral white matter were 4.01 ± 0.47 (mean ± SD) and 3.01 ± 0.39 ml per 100 ml. Lobar PBV values were: frontal lobe 4.2 ± 0.8, temporal lobe 4.2 ± 0.9, parietal lobe 3.9 ± 0.7 and occipital lobe 4.3 ± 0.8 ml/100 ml. The basal ganglia and brainstem PBV values were 3.4 ± 0.7 and 4.6 ± 0.6 ml/100 ml, respectively. Conclusions Compared with the typical reference cerebral blood volume (CBV) values reported in the literature for Positron Emission Tomography (PET), the PBV values were relatively high for the white matter and relatively low for the cortical grey matter. The reported catalogue of PBV values for various brain regions would be useful to inform future studies and could be used in clinical practice, when interpreting PBV maps. PMID:26769737

  4. Whole brain C-arm computed tomography parenchymal blood volume measurements.

    PubMed

    Kamran, Mudassar; Byrne, James V

    2016-04-01

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) imaging in the neuro-interventional suite is a new technique for which detailed whole brain measurements have not been previously reported. This study aims to create a catalogue of PBV measurements for various anatomical regions encompassing the whole brain, using a three-dimensional volume-of-interest (3D-VOI) analysis. We acquired and analysed 30 C-arm FDCT datasets from 26 patients with aneurysmal subarachnoid haemorrhage (SAH), as part of a prospective study comparing C-arm computed tomography (CT) PBV with magnetic resonance perfusion-weighted imaging (MR-PWI). We calculated the PBV values for various brain regions with an automated analysis, using 58 pre-defined atlas-based 3D-VOIs encompassing the whole brain. VOIs partially or completely overlapping regions of magnetic resonance diffusion weighted imaging (MR-DWI) abnormality or magnetic resonance cerebral blood flow (MR-CBF) asymmetry were excluded from the analysis. Of the 30 C-arm CT PBV datasets, 14 (54%; 12 patients) had areas of restricted diffusion, the majority of which were focal. The PBV values for the cerebral cortex and cerebral white matter were 4.01 ± 0.47 (mean ± SD) and 3.01 ± 0.39 ml per 100 ml. Lobar PBV values were: frontal lobe 4.2 ± 0.8, temporal lobe 4.2 ± 0.9, parietal lobe 3.9 ± 0.7 and occipital lobe 4.3 ± 0.8 ml/100 ml. The basal ganglia and brainstem PBV values were 3.4 ± 0.7 and 4.6 ± 0.6 ml/100 ml, respectively. Compared with the typical reference cerebral blood volume (CBV) values reported in the literature for Positron Emission Tomography (PET), the PBV values were relatively high for the white matter and relatively low for the cortical grey matter. The reported catalogue of PBV values for various brain regions would be useful to inform future studies and could be used in clinical practice, when interpreting PBV maps. © The Author(s) 2016.

  5. Comparison of Hybrid K-Edge Densitometer (HKED) Performance Operating with the Canberra Lynx MCA and the Canberra ICB-NIM Electronics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McElroy, Robert Dennis

    From the 1991 until 2008 the Canberra Hybrid K-Edge Densitometer systems were provided with ICB-NIM (Integrated Control Bus – Nuclear Instrument Module) acquisition electronics. Newer electronics modules, such as the Lynx, were not supported under the VMS based operating system. The LYNX module was provided as the standard acquisition electronics following the release of the Windows based CHKED software. This report compares the electronics dead-time, gain shifts, detector resolution and measurement performance of the HKED system operated with the two types of acquisition modules. The comparison was performed using measurements obtained with the ORNL HKED system. The original intent ofmore » this study was to take advantage of both the timing and energy outputs from the HPGE detector to acquire data with both sets of electronics in parallel. Although this approach has been applied successfully with other systems, in this case we found the timing output produced a significant amount of noise such that a comparison between the electronics would be invalid. So the comparative measurements were performed sequentially. The ICB-NIM data was acquired over the course of 12 months with 255 measurements while the LYNX data was acquired over a period of 10 months with 75 measurements. To simplify the comparison, all data used in this study was acquired using the Canberra CHKED (V1.0) software package. The performance analysis was based primarily on the peak locations, peak widths and concentration values reported by the CHKED software. The raw spectra from the XRF measurements were also examined to extract additional 109Cd peak location and width data for the hybrid measurements (the standard hybrid report template does not report these values).« less

  6. SUPPLEMENTARY COMPARISON: Final report of the bilateral comparison APMP.M.H-S2 of hardness measurement for Rockwell scales A and B between PTB and NIMT

    NASA Astrophysics Data System (ADS)

    Sanponpute, Tassanai; Meesaplak, Apichaya; Herrmann, Konrad; Menelao, Febo

    2009-01-01

    The bilateral comparison APMP.M.H-S2 of hardness measurement for Rockwell scales A and B was arranged by the National Institute of Metrology of Thailand, NIMT, as the pilot laboratory, comparing with Physikalisch-Technische Bundesanstalt of Germany, PTB. The objective of this comparison was to confirm the calibration and measurement capabilities of NIMT in hardness measurement. The period of measurement covered March to August 2009. There were two sets of artefacts: scale A artefact set and scale B artefact set. The scale A artefact set consisted of seven hardness blocks: 35 HRA, 40 HRA, 55 HRA, 60 HRA, 70 HRA, 80 HRA, 85 HRA. The artefact set for scale B consisted of nine hardness blocks: 25 HRB, 30 HRB, 40 HRB, 50 HRB, 60 HRB, 70 HRB, 80 HRB, 90 HRB, 100 HRB. Laboratories had to ensure that the primary Rockwell hardness machines passed the verification process according to ISO 6508-3. Then participants measured the hardness value by making ten indentations in a designated area of each artefact block. Hardness measurement results and uncertainty budget were then reported to the pilot laboratory and were used to compute the degrees of equivalence in terms of the Comparison Reference Value (CRV) and En ratio. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  7. An International Standard Set of Patient-Centered Outcome Measures After Stroke.

    PubMed

    Salinas, Joel; Sprinkhuizen, Sara M; Ackerson, Teri; Bernhardt, Julie; Davie, Charlie; George, Mary G; Gething, Stephanie; Kelly, Adam G; Lindsay, Patrice; Liu, Liping; Martins, Sheila C O; Morgan, Louise; Norrving, Bo; Ribbers, Gerard M; Silver, Frank L; Smith, Eric E; Williams, Linda S; Schwamm, Lee H

    2016-01-01

    Value-based health care aims to bring together patients and health systems to maximize the ratio of quality over cost. To enable assessment of healthcare value in stroke management, an international standard set of patient-centered stroke outcome measures was defined for use in a variety of healthcare settings. A modified Delphi process was implemented with an international expert panel representing patients, advocates, and clinical specialists in stroke outcomes, stroke registers, global health, epidemiology, and rehabilitation to reach consensus on the preferred outcome measures, included populations, and baseline risk adjustment variables. Patients presenting to a hospital with ischemic stroke or intracerebral hemorrhage were selected as the target population for these recommendations, with the inclusion of transient ischemic attacks optional. Outcome categories recommended for assessment were survival and disease control, acute complications, and patient-reported outcomes. Patient-reported outcomes proposed for assessment at 90 days were pain, mood, feeding, selfcare, mobility, communication, cognitive functioning, social participation, ability to return to usual activities, and health-related quality of life, with mobility, feeding, selfcare, and communication also collected at discharge. One instrument was able to collect most patient-reported subdomains (9/16, 56%). Minimum data collection for risk adjustment included patient demographics, premorbid functioning, stroke type and severity, vascular and systemic risk factors, and specific treatment/care-related factors. A consensus stroke measure Standard Set was developed as a simple, pragmatic method to increase the value of stroke care. The set should be validated in practice when used for monitoring and comparisons across different care settings. © 2015 The Authors.

  8. CCQM-K140: carbon stable isotope ratio delta values in honey

    NASA Astrophysics Data System (ADS)

    Dunn, P. J. H.; Goenaga-Infante, H.; Goren, A. C.; Şimşek, A.; Bilsel, M.; Ogrinc, N.; Armishaw, P.; Hai, L.

    2017-01-01

    As there can be small but measureable differences in isotope ratios between different sources of the same element/compound/material, isotope ratio measurements are applied in a number of different fields including archaeology, environmental science, geochemistry, forensic science and ecology. Isotope ratios for the light elements (H, C, N, O and S) are typically reported as δ-values which are isotope ratios expressed relative to an internationally agreed standard (this standard is the zero-point on the scale), although absolute isotope ratios which are traceable to the SI have also been reported. The IAWG has been granted a traceability exception for the use of arbitrary delta scales until SI traceability can be established at the required level of uncertainty but this goal is some years away. While the CCQM IAWG has previously organised several pilot studies on isotope ratio determination (CCQM-P75: Stable isotope delta values in methionine, 2006; CCQM-P105: Sr isotope ratios in wine, 2008; CCQM-K98: Pb isotope ratios in bronze with additional delta values in CCQM-P134, 2011), it has been a number of years since delta values of light elements have been considered and there has been no key comparison (KC). Therefore, the IAWG has included the need for a KC (CCQM-K140) based on an arbitrary delta scale in its program to support ongoing requirements to demonstrate core capabilities as well as specific claims of measurement capability (CMCs) in this area. The performance of all five of the CCQM-K140 participants was very good, illustrating their ability to obtain accurate results for carbon isotope ratios, within the calibration range afforded by internationally agreed reference materials (δ13CVPDB-LSVEC between -47.32 % and +535.3 %) with measurement uncertainties of between 0.08 and 0.28 %. This was despite the fact that no two participants used exactly the same approach in terms of instrumentation or data treatment. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. The Math–Biology Values Instrument: Development of a Tool to Measure Life Science Majors’ Task Values of Using Math in the Context of Biology

    PubMed Central

    Andrews, Sarah E.; Runyon, Christopher; Aikens, Melissa L.

    2017-01-01

    In response to calls to improve the quantitative training of undergraduate biology students, there have been increased efforts to better integrate math into biology curricula. One challenge of such efforts is negative student attitudes toward math, which are thought to be particularly prevalent among biology students. According to theory, students’ personal values toward using math in a biological context will influence their achievement and behavioral outcomes, but a validated instrument is needed to determine this empirically. We developed the Math–Biology Values Instrument (MBVI), an 11-item college-level self-­report instrument grounded in expectancy-value theory, to measure life science students’ interest in using math to understand biology, the perceived usefulness of math to their life science career, and the cost of using math in biology courses. We used a process that integrates multiple forms of validity evidence to show that scores from the MBVI can be used as a valid measure of a student’s value of math in the context of biology. The MBVI can be used by instructors and researchers to help identify instructional strategies that influence math–biology values and understand how math–biology values are related to students’ achievement and decisions to pursue more advanced quantitative-based courses. PMID:28747355

  10. Distributions of p-values smaller than .05 in psychology: what is going on?

    PubMed Central

    van Aert, Robbie C.M.; Nuijten, Michèle B.; Wicherts, Jelte M.; van Assen, Marcel A.L.M.

    2016-01-01

    Previous studies provided mixed findings on pecularities in p-value distributions in psychology. This paper examined 258,050 test results across 30,710 articles from eight high impact journals to investigate the existence of a peculiar prevalence of p-values just below .05 (i.e., a bump) in the psychological literature, and a potential increase thereof over time. We indeed found evidence for a bump just below .05 in the distribution of exactly reported p-values in the journals Developmental Psychology, Journal of Applied Psychology, and Journal of Personality and Social Psychology, but the bump did not increase over the years and disappeared when using recalculated p-values. We found clear and direct evidence for the QRP “incorrect rounding of p-value” (John, Loewenstein & Prelec, 2012) in all psychology journals. Finally, we also investigated monotonic excess of p-values, an effect of certain QRPs that has been neglected in previous research, and developed two measures to detect this by modeling the distributions of statistically significant p-values. Using simulations and applying the two measures to the retrieved test results, we argue that, although one of the measures suggests the use of QRPs in psychology, it is difficult to draw general conclusions concerning QRPs based on modeling of p-value distributions. PMID:27077017

  11. Wanting, liking, and preference construction.

    PubMed

    Dai, Xianchi; Brendl, C Miguel; Ariely, Dan

    2010-06-01

    According to theories on preference construction, multiple preferences result from multiple contexts (e.g., loss vs. gain frames). This implies that people can have different representations of a preference in different contexts. Drawing on Berridge's (1999) distinction between unconscious liking and wanting, we hypothesize that people may have multiple representations of a preference toward an object even within a single context. Specifically, we propose that people can have different representations of an object's motivational value, or incentive value, versus its emotional value, or likability, even when the object is placed in the same context. Study 1 establishes a divergence between incentive value and likability of faces using behavioral measures. Studies 2A and 2B, using self-report measures, provide support for our main hypothesis that people are perfectly aware of these distinct representations and are able to access them concurrently at will. We also discuss implications of our findings for the truism that people seek pleasure and for expectancy-value theories.

  12. Value-Based Assessment of Radiology Reporting Using Radiologist-Referring Physician Two-Way Feedback System-a Design Thinking-Based Approach.

    PubMed

    Shaikh, Faiq; Hendrata, Kenneth; Kolowitz, Brian; Awan, Omer; Shrestha, Rasu; Deible, Christopher

    2017-06-01

    In the era of value-based healthcare, many aspects of medical care are being measured and assessed to improve quality and reduce costs. Radiology adds enormously to health care costs and is under pressure to adopt a more efficient system that incorporates essential metrics to assess its value and impact on outcomes. Most current systems tie radiologists' incentives and evaluations to RVU-based productivity metrics and peer-review-based quality metrics. In a new potential model, a radiologist's performance will have to increasingly depend on a number of parameters that define "value," beginning with peer review metrics that include referrer satisfaction and feedback from radiologists to the referring physician that evaluates the potency and validity of clinical information provided for a given study. These new dimensions of value measurement will directly impact the cascade of further medical management. We share our continued experience with this project that had two components: RESP (Referrer Evaluation System Pilot) and FRACI (Feedback from Radiologist Addressing Confounding Issues), which were introduced to the clinical radiology workflow in order to capture referrer-based and radiologist-based feedback on radiology reporting. We also share our insight into the principles of design thinking as applied in its planning and execution.

  13. In vivo estimates of NO and CO conductance for haemoglobin and for lung transfer in humans.

    PubMed

    Guénard, Hervé Jean-Pierre; Martinot, Jean-Benoit; Martin, Sebastien; Maury, Bertrand; Lalande, Sophie; Kays, Christian

    2016-07-01

    Membrane conductance (Dm) and capillary lung volume (Vc) derived from NO and CO lung transfer measurements in humans depend on the blood conductance (θ) values of both gases. Many θ values have been proposed in the literature. In the present study, measurements of CO and NO transfer while breathing 15% or 21% O2 allowed the estimation of θNO and the calculation of the optimal equation relating 1/θCO to pulmonary capillary oxygen pressure (PcapO2). In 10 healthy subjects, the mean calculated θNO value was similar to the θNO value previously reported in the literature (4.5mmHgmin(-1)) provided that one among three θCO equations from the literature was chosen. Setting 1/θCO=a·PcapO2+b, optimal values of a and b could be chosen using two methods: 1) by minimizing the difference between Dm/Vc ratios for any PcapO2, 2) by establishing a linear equation relating a and b. Using these methods, we are proposing the equation 1/θCO=0.0062·PcapO2+1.16, which is similar to two equations previously reported in the literature. With this set of θ values, DmCO reached the morphometric range. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Quantification of bone strength by intraoperative torque measurement: a technical note.

    PubMed

    Suhm, Norbert; Haenni, Markus; Schwyn, Ronald; Hirschmann, Michael; Müller, Andreas Marc

    2008-06-01

    Bone strength describes the resistance of bone against mechanical failure. Bone strength depends on both the amount of bone and the bone's quality, and the bone strength may be looked upon as a relevant parameter to judge an osteosynthesis' stability. Information about bone strength was barely available intraoperatively in the past. The previous work of our group reported on development and laboratory evaluation of mechanical torque measurement as a method for the intraoperative quantification of bone strength. With the clinical series presented here we intend to verify that the im gesamten Text DensiProbe instrumentation for intraoperative torque measurement and the related measurement method are eligible for intraoperative use based on the following criteria: application of the method may not create complications, the measurement can be performed by the surgeon himself and may only cause a limited increase in the procedure time. From December 2006 until May 2007 ten patients with a pertrochanteric femoral fracture or a lateral femoral neck fracture eligible for stabilization with DHS were included in the study after having received informed consent. Any medication and comorbidity that might have influenced bone quality or bone mineral density (BMD) in these patients was documented. Bone strength was intraoperatively measured with DensiProbe. Complications that were obviously related with torque measurement were documented as well as any deviation from the suggested procedure; 6 and 12 weeks postoperative follow-up included clinical and radiological examination. The time required for torque measurement, the overall operating time and the number of persons present in the operating room were protocolled. BMD values of the contralateral femoral neck were postoperatively assessed by dual energy X-ray absorptiometry (DEXA) and compared to intraoperative peak torque values measured by DensiProbe. No major complication was observed during intraoperative application of DensiProbe by trained surgeons. The unintended extraction of the guide wire together with the torque measurement probe was reported only once and is looked upon as a minor complication. Fracture healing was uneventful in all patients. The mean time for torque measurement was 2.35 +/- 0.9 min accounting for 2.2 +/- 1.1% of total surgery time. The presence of an additional person was not required to perform torque measurement but to protocol the data. There was a tendency towards correlation between BMD values of the femoral neck and intraoperative peak torque values. The data presented clearly indicate that the DensiProbe instrumentation and measurement principle are eligible for routine intraoperative use by trained surgeons. Interpretation of possible correlations between BMD values measured by means of DEXA and the Peak Torque values assessed by DensiProbe has to be considered very carefully, because BMD and Peak Torque analyse bone at a different scale. Only within the framework of a multicenter study it will be possible to include a sufficient number of patients for calculation of the methods' predictive value towards implant failure and to verify acceptance of the method by the surgeons.

  15. Studying Food Reward and Motivation in Humans

    PubMed Central

    Ziauddeen, Hisham; Subramaniam, Naresh; Cambridge, Victoria C.; Medic, Nenad; Farooqi, Ismaa Sadaf; Fletcher, Paul C.

    2014-01-01

    A key challenge in studying reward processing in humans is to go beyond subjective self-report measures and quantify different aspects of reward such as hedonics, motivation, and goal value in more objective ways. This is particularly relevant for the understanding of overeating and obesity as well as their potential treatments. In this paper are described a set of measures of food-related motivation using handgrip force as a motivational measure. These methods can be used to examine changes in food related motivation with metabolic (satiety) and pharmacological manipulations and can be used to evaluate interventions targeted at overeating and obesity. However to understand food-related decision making in the complex food environment it is essential to be able to ascertain the reward goal values that guide the decisions and behavioral choices that people make. These values are hidden but it is possible to ascertain them more objectively using metrics such as the willingness to pay and a method for this is described. Both these sets of methods provide quantitative measures of motivation and goal value that can be compared within and between individuals. PMID:24686284

  16. Studying food reward and motivation in humans.

    PubMed

    Ziauddeen, Hisham; Subramaniam, Naresh; Cambridge, Victoria C; Medic, Nenad; Farooqi, Ismaa Sadaf; Fletcher, Paul C

    2014-03-19

    A key challenge in studying reward processing in humans is to go beyond subjective self-report measures and quantify different aspects of reward such as hedonics, motivation, and goal value in more objective ways. This is particularly relevant for the understanding of overeating and obesity as well as their potential treatments. In this paper are described a set of measures of food-related motivation using handgrip force as a motivational measure. These methods can be used to examine changes in food related motivation with metabolic (satiety) and pharmacological manipulations and can be used to evaluate interventions targeted at overeating and obesity. However to understand food-related decision making in the complex food environment it is essential to be able to ascertain the reward goal values that guide the decisions and behavioral choices that people make. These values are hidden but it is possible to ascertain them more objectively using metrics such as the willingness to pay and a method for this is described. Both these sets of methods provide quantitative measures of motivation and goal value that can be compared within and between individuals.

  17. Electrode effects in dielectric spectroscopy measurements on (Nb+In) co-doped TiO2

    NASA Astrophysics Data System (ADS)

    Crandles, D. A.; Yee, S. M. M.; Savinov, M.; Nuzhnyy, D.; Petzelt, J.; Kamba, S.; Prokeš, J.

    2016-04-01

    Recently, several papers reported the discovery of giant permittivity and low dielectric loss in (Nb+In) co-doped TiO2. A series of tests was performed which included the measurement of the frequency dependence of the dielectric permittivity and alternating current (ac) conductivity of co-doped (Nb+In)TiO2 as a function of electrode type, sample thickness, and temperature. The data suggest that the measurements are strongly affected by the electrodes. The consistency between four-contact van der Pauw direct current conductivity measurements and bulk conductivity values extracted from two-contact ac conductivity measurements suggest that the values of colossal permittivity are, at least in part, a result of Schottky barrier depletion widths that depend on electrode type and temperature.

  18. Electrode effects in dielectric spectroscopy measurements on (Nb +In) co-doped TiO2

    NASA Astrophysics Data System (ADS)

    Crandles, David; Yee, Susan; Savinov, Maxim; Nuzhnyy, Dimitri; Petzelt, Jan; Kamba, Stanislav; Prokes, Jan

    Recently, several papers reported the discovery of giant permittivity and low dielectric loss in (Nb+In) co-doped TiO2. A series of tests was performed which included the measurement of the frequency dependence of the dielectric permittivity and ac conductivity of co-doped (Nb+In)TiO2 as a function of electrode type, sample thickness and temperature. The data suggest that the measurements are strongly affected by the electrodes. The consistency between four contact van der Pauw dc conductivity measurements and bulk conductivity values extracted from two contact ac conductivity measurements suggest that the values of colossal permittivity are, at least in part, a result of Schottky barrier depletion widths that depend on electrode type and temperature. Nserc, Czech Science Foundation (Project 15-08389S).

  19. Final report on the regional supplementary comparison APMP.AUV.A-S1

    NASA Astrophysics Data System (ADS)

    Plangsangmas, Virat; Leeudomwong, Surat; Scott, Andrew; Zhong, Bo; Huang, Yuchung

    2014-01-01

    A regional supplementary comparison APMP.AUV.A-S1 has been carried out for the measurement of sound pressure level, frequency and total distortion of a multi-frequency sound calibrator. The role of the Pilot laboratory was undertaken by the National Institute of Metrology (Thailand) (NIMT). The multi-frequency sound calibrator was circulated through thirteen National Metrology Institutes (NMIs). Two NMIs were added to the original time schedule after starting the circulation. The measurements took place between September 2008 and July 2010. This report includes the measurement results from all the participants. Supplementary Comparison Reference Values (SCRVs) have been determined from the results. Deviations from the SCRVs are mostly within declared expanded uncertainties. It has been found that a term for the inherent instability in this type of device needs to be included in any uncertainty budget, and a recommended minimum value of this has been given. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Q branches of the nu7 fundamental of ethane (C2H6) Integrated intensity measurements for atmospheric measurement applications

    NASA Technical Reports Server (NTRS)

    Rinsland, C. P.; Harvey, G. A.; Levine, J. S.; Smith, M. A. H.; Malathy Devi, V.; Thakur, K. B.

    1986-01-01

    Laboratory spectra covering the nu7 band of ethane (C2H6) have been recorded, and measurements of integrated intensities of selected Q branches from these spectra are reported. The method by which the spectra were obtained is described, and a typical spectrum covering the PQ3 branch at 2976.8/cm is shown along with a plot of equivalent width vs. optical density for this branch. The values of the integrated intensities reported for each branch are the means of five different optical densities.

  1. Radioactivity level and toxic elemental concentration in groundwater at Dei-Dei and Kubwa areas of Abuja, north-central Nigeria

    NASA Astrophysics Data System (ADS)

    Maxwell, O.; Wagiran, H.; Lee, S. K.; Embong, Z.; Ugwuoke, P. E.

    2015-02-01

    The activity concentrations of uranium and toxic elements in Dei-Dei borehole, Kubwa borehole, Water Board and hand-dug well water samples in Abuja area were measured using inductively coupled plasma mass spectrometry (ICP-MS) system. The results obtained were used to calculate human radiological risk over lifetime consumption by the inhabitants in the area. The activity concentrations of 238U in all the water supplies for drinking ranges from 0.849 mBq L-1 to 2.699 mBq L-1 with the highest value of 2.699 mBq L-1 noted at Dei-Dei borehole whereas the lowest value of 0.849 mBq L-1 was noted in Kubwa borehole. The highest annual effective dose from natural 238U in all the water samples was found in Dei-Dei borehole with a value of 8.9×10-5 mSv y-1 whereas the lowest value was noted in Kubwa borehole with a value of 2.8×10-5 mSv y-1. The radiological risks for cancer mortality were found distinctly low, with the highest value of 1.01×10-7 reported at Dei-Dei borehole compared to Kubwa borehole with a value of 3.01×10-8. The cancer morbidity risk was noted higher in Dei-Dei borehole with a value of 1.55×10-7 whereas lower value of 4.88×10-9 was reported in Kubwa borehole. The chemical toxicity risk of 238U in drinking water over a lifetime consumption has a value of 0.006 μg kg-1 day-1 in Dei-Dei borehole whereas lower value of 0.002 μg kg-1 day-1 was found in Kubwa borehole. Measured lead (Pb) and chromium (Cr) concentrations reported higher in Water Board compared to Dei-Dei and Kubwa borehole samples. Significantly, this study inferred that the 238U concentrations originate from granitic strata of the tectonic events in the area; thus, there was a trend of diffusion towards north to south and re-deposition towards Dei-Dei area.

  2. National Assessment Program--Civics and Citizenship Years 6 & 10 Report, 2004

    ERIC Educational Resources Information Center

    Mellor, Suzanne; Ainley, John; Fraillon, Julian; Wernert, Nicole

    2006-01-01

    The National Assessment Program--Civics and Citizenship assessment measures the civic knowledge and understanding and the citizenship participation skills and civic values of Year 6 and Year 10 students in schools across Australia. It reports on student achievement using proficiency levels on a common civics and citizenship assessment scale, and…

  3. Measuring School Effectiveness: Technical Report on the 2011 Value-Added Model. Technical Report

    ERIC Educational Resources Information Center

    National Center on Scaling Up Effective Schools, 2014

    2014-01-01

    High school dropout, enrollment, and graduation rates are important indicators of students' college and career readiness, which in turn significantly impact both individual income levels and the overall knowledge-driven economy. Despite the long-term benefits of a high school education, much of the current literature on raising school…

  4. Lens of Eye Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mallett, Michael Wesley

    An analysis of LANL occupational dose measurements was made with respect to lens of eye dose (LOE), in particular, for plutonium workers. Table 1 shows the reported LOE as a ratio of the “deep” (photon only) and “deep+neutron” dose for routine monitored workers at LANL for the past ten years. The data compares the mean and range of these values for plutonium workers* and non-routine plutonium workers. All doses were reported based on measurements with the LANL Model 8823 TLD.

  5. Using Clinical Data Standards to Measure Quality: A New Approach.

    PubMed

    D'Amore, John D; Li, Chun; McCrary, Laura; Niloff, Jonathan M; Sittig, Dean F; McCoy, Allison B; Wright, Adam

    2018-04-01

     Value-based payment for care requires the consistent, objective calculation of care quality. Previous initiatives to calculate ambulatory quality measures have relied on billing data or individual electronic health records (EHRs) to calculate and report performance. New methods for quality measure calculation promoted by federal regulations allow qualified clinical data registries to report quality outcomes based on data aggregated across facilities and EHRs using interoperability standards.  This research evaluates the use of clinical document interchange standards as the basis for quality measurement.  Using data on 1,100 patients from 11 ambulatory care facilities and 5 different EHRs, challenges to quality measurement are identified and addressed for 17 certified quality measures.  Iterative solutions were identified for 14 measures that improved patient inclusion and measure calculation accuracy. Findings validate this approach to improving measure accuracy while maintaining measure certification.  Organizations that report care quality should be aware of how identified issues affect quality measure selection and calculation. Quality measure authors should consider increasing real-world validation and the consistency of measure logic in respect to issues identified in this research. Schattauer GmbH Stuttgart.

  6. Critical evaluation of energy intake using the Goldberg cut-off for energy intake:basal metabolic rate. A practical guide to its calculation, use and limitations.

    PubMed

    Black, A E

    2000-09-01

    To re-state the principles underlying the Goldberg cut-off for identifying under-reporters of energy intake, re-examine the physiological principles and update the values to be substituted into the equation for calculating the cut-off, and to examine its use and limitations. New values are suggested for each element of the Goldberg equation. The physical activity level (PAL) for comparison with energy intake:basal metabolic rate (EI:BMR) should be selected to reflect the population under study; the PAL value of 1.55 x BMR is not necessarily the value of choice. The suggested value for average within-subject variation in energy intake is 23% (unchanged), but other sources of variation are increased in the light of new data. For within-subject variation in measured and estimated BMR, 4% and 8.5% respectively are suggested (previously 2.5% and 8%), and for total between-subject variation in PAL, the suggested value is 15% (previously 12.5%). The effect of these changes is to widen the confidence limits and reduce the sensitivity of the cut-off. The Goldberg cut-off can be used to evaluate the mean population bias in reported energy intake, but information on the activity or lifestyle of the population is needed to choose a suitable PAL energy requirement for comparison. Sensitivity for identifying under-reporters at the individual level is limited. In epidemiological studies information on home, leisure and occupational activity is essential in order to assign subjects to low, medium or high PAL levels before calculating the cut-offs. In small studies, it is desirable to measure energy expenditure, or to calculate individual energy requirements, and to compare energy intake directly with energy expenditure.

  7. An application of the SF-6D to create heath values in Portuguese working age adults.

    PubMed

    Ferreira, Lara Noronha; Ferreira, Pedro Lopes; Pereira, Luís Nobre; Brazier, John

    2008-01-01

    This study describes the health-related quality of life (HRQOL) of the Portuguese working age population and investigates sociodemographic differences. Subjects randomly selected from the working age population (n=2,459) were assessed using the SF-36v2 and converted into the preference-based SF-6D. The mean SF-6D utility value was 0.70 (range 0.63-0.73). The mean utility value was lower for the lower educational level than for the highest. Women, people living in rural areas and older adults reported lower levels of utility values. Non-parametric tests showed that health utility values were significantly related to employment; unskilled manual workers reported utility values lower than non-manual workers. For different diseases, mean utility values ranged from 0.58 (sexual diseases) to 0.66 (hepatic conditions). Cluster analysis was adopted to classify individuals into three groups according to their answers to the SF-6D dimensions. Multinomial logit regression was used to detect sociodemographic characteristics affecting the probability of following each cluster pattern. This study yielded normative data by age and gender for the SF-6D. The authors conclude that SF-6D is an effective tool for measuring HRQOL in the community so that different population groups can be compared. The preference-based measure used seems to discriminate adequately across sociodemographic differences. These results allow a better understanding of the impact of sociodemographic variables on the burden of illness perception.

  8. Acquaintance ratings of the Big Five personality traits: incremental validity beyond and interactive effects with self-reports in the prediction of workplace deviance.

    PubMed

    Kluemper, Donald H; McLarty, Benjamin D; Bing, Mark N

    2015-01-01

    It is widely established that the Big Five personality traits of conscientiousness, agreeableness, and emotional stability are antecedents to workplace deviance (Berry, Ones, & Sackett, 2007). However, these meta-analytic findings are based on self-reported personality traits. A recent meta-analysis by Oh, Wang, and Mount (2011) identified the value of acquaintance-reported personality in the prediction of job performance. The current investigation extends prior work by comparing the validities of self- and acquaintance-reported personality in the prediction of workplace deviance across 2 studies. We also hypothesized and tested an interactive, value-added integration of self- with acquaintance-reported personality using socioanalytic personality theory (R. T. Hogan, 1991). Both studies assessed self- and acquaintance-rated Big Five traits, along with supervisor-rated workplace deviance. However, the studies varied the measures of workplace deviance, and the 2nd study also included a self-rated workplace deviance criterion for additional comparison. Across both studies, the traits of conscientiousness and agreeableness were strong predictors of workplace deviance, and acquaintance-reported personality provided incremental validity beyond self-reports. Additionally, acquaintance-reported conscientiousness and agreeableness moderated the prediction of workplace deviance by interacting with the corresponding self-reported traits. Implications for personality theory and measurement are discussed along with applications for practice. (c) 2015 APA, all rights reserved.

  9. Variability in effective radiating area and output power of new ultrasound transducers at 3 MHz.

    PubMed

    Johns, Lennart D; Straub, Stephen J; Howard, Samuel M

    2007-01-01

    Spatial average intensity (SAI) is often used by clinicians to gauge therapeutic ultrasound dosage, yet SAI measures are not directly regulated by US Food and Drug Administration (FDA) standards. Current FDA guidelines permit a possible 50% to 150% minimum to maximum range of SAI values, potentially contributing to variability in clinical outcomes. To measure clinical values that describe ultrasound transducers and to determine the degree of intramanufacturer and intermanufacturer variability in effective radiating area, power, and SAI when the transducer is functioning at 3 MHz. A descriptive and interferential approach was taken to this quasi-experimental design. Measurement laboratory. Sixty-six 5-cm(2) ultrasound transducers were purchased from 6 different manufacturers. All transducers were calibrated and then assessed using standardized measurement techniques; SAI was normalized to account for variability in effective radiating area, resulting in an nSAI. Effective radiating area, power, and nSAI. All manufacturers with the exception of Omnisound (P = .534) showed a difference between the reported and measured effective radiating area values (P < .001). All transducers were within FDA guidelines for power (+/-20%). Chattanooga (0.85 +/- 0.05 W/cm(2)) had a lower nSAI (P < .05) than all other manufacturers functioning at 3 MHz. Intramanufacturer variability in SAI ranged from 16% to 35%, and intermanufacturer variability ranged from 22% to 61%. Clinicians should consider treatment values of each individual transducer, regardless of the manufacturer. In addition, clinicians should scrutinize the power calibration and recalibration record of the transducer and adjust clinical settings as needed for the desired level of heating. Our data may aid in explaining the reported heating differences among transducers from different manufacturers. Stricter FDA standards regarding effective radiating area and total power are needed, and standards regulating SAI should be established.

  10. Patient-Reported Outcome Measures for Use in Clinical Trials and Clinical Practice in Inflammatory Bowel Diseases: A Systematic Review.

    PubMed

    de Jong, Marin J; Huibregtse, Roxanne; Masclee, Ad A M; Jonkers, Daisy M A E; Pierik, Marie J

    2018-05-01

    Mucosal inflammation must be carefully monitored to improve the long-term outcomes of patients with inflammatory bowel diseases (IBD). Patient-reported outcome measures (PROMs) are used increasingly to monitor disease activity in clinical practice and as endpoints in clinical trials. We performed a systematic review to provide an overview of the available PROMs on IBD activity and to evaluate their diagnostic value. A systematic search of the PubMed, Medline, Cochrane library, and Embase databases using defined keywords, identified 973 articles. These were screened by 2 independent reviewers, and 37 articles on development or validation of PROMs to assess IBD activity were identified for further analysis. Based on the recommendations of the Food and Drug Administration (FDA), the following measurement properties were evaluated: content, construct, and criterion validity; reliability; and responsiveness to change. In addition, data on ease of use in clinical practice were collected. Seventeen articles presenting 20 different PROMs were included the final analysis, although none met all the FDA-recommended criteria. Only 2 PROMs (patient-reported Harvey Bradshaw Index and Simple Clinical Colitis Activity Index scores) reported patient involvement during its development. Only 6 PROMs (patient-reported global assessment, patient assessment of disease activity, mobile health index for Crohn's disease, mobile health index for ulcerative colitis, patient-reported outcome derived from the Mayo score, and the 6-point Mayo score) were validated as markers of IBD activity, using findings from endoscopy as the reference standard; these PROMs identified patients with mucosal inflammation with area under the curve values of 0.63-0.82. The mobile health index for CD and UC scores had the best measurement properties for use in clinical practice and in clinical trials. In a systematic review, we identified more than 20 PROMS that have been developed and tested for their ability to determine IBD activity. Further studies are needed to determine their accuracy and whether they can be used effectively in routine practice, clinical trials, telemedicine systems, and value-based healthcare programs. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  11. Measurement Error and Bias in Value-Added Models. Research Report. ETS RR-17-25

    ERIC Educational Resources Information Center

    Kane, Michael T.

    2017-01-01

    By aggregating residual gain scores (the differences between each student's current score and a predicted score based on prior performance) for a school or a teacher, value-added models (VAMs) can be used to generate estimates of school or teacher effects. It is known that random errors in the prior scores will introduce bias into predictions of…

  12. OPEN PROBLEM: Orbits' statistics in chaotic dynamical systems

    NASA Astrophysics Data System (ADS)

    Arnold, V.

    2008-07-01

    This paper shows how the measurement of the stochasticity degree of a finite sequence of real numbers, published by Kolmogorov in Italian in a journal of insurances' statistics, can be usefully applied to measure the objective stochasticity degree of sequences, originating from dynamical systems theory and from number theory. Namely, whenever the value of Kolmogorov's stochasticity parameter of a given sequence of numbers is too small (or too big), one may conclude that the conjecture describing this sequence as a sample of independent values of a random variables is highly improbable. Kolmogorov used this strategy fighting (in a paper in 'Doklady', 1940) against Lysenko, who had tried to disprove the classical genetics' law of Mendel experimentally. Calculating his stochasticity parameter value for the numbers from Lysenko's experiment reports, Kolmogorov deduced, that, while these numbers were different from the exact fulfilment of Mendel's 3 : 1 law, any smaller deviation would be a manifestation of the report's number falsification. The calculation of the values of the stochasticity parameter would be useful for many other generators of pseudorandom numbers and for many other chaotically looking statistics, including even the prime numbers distribution (discussed in this paper as an example).

  13. Underwater study of arterial blood pressure in breath-hold divers.

    PubMed

    Sieber, Arne; L'abbate, Antonio; Passera, Mirko; Garbella, Erika; Benassi, Antonio; Bedini, Remo

    2009-11-01

    Knowledge regarding arterial blood pressure (ABP) values during breath-hold diving is scanty. It derives from a few reports of measurements performed at the water's surface, showing slight or no increase in ABP, and from a single study of two simulated deep breath-hold dives in a hyperbaric chamber. Simulated dives showed an increase in ABP to values considered life threatening by standard clinical criteria. For the first time, using a novel noninvasive subaquatic sphygmomanometer, we successfully measured ABP in 10 healthy elite breath-hold divers at a depth of 10 m of freshwater (mfw). ABP was measured in dry conditions, at the surface (head-out immersion), and twice at a depth of 10 mfw. Underwater measurements of ABP were obtained in all subjects. Each measurement lasted 50-60 s and was accomplished without any complications or diver discomfort. In the 10 subjects as a whole, mean ABP values were 124/93 mmHg at the surface and 123/94 mmHg at a depth of 10 mfw. No significant statistical differences were found when blood pressure measurements at the water surface were compared with breath-hold diving conditions at a depth of 10 mfw. No systolic blood pressure values >140 mmHg or diastolic blood pressure values >115 mmHg were recorded. In conclusion, direct measurements of ABP during apnea diving showed no or only mild increases in ABP. However, our results cannot be extended over environmental conditions different from those of the present study.

  14. Intercomparison of active, passive and continuous instruments for radon and radon progeny measurements in the EML chamber and test facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scarpitta, S.C.; Tu, K.W.; Fisenne, I.M.

    1996-10-01

    Results are presented from the Fifth Intercomparison of Active, Passive and Continuous Instruments for Radon and Radon Progeny Measurements conducted in the EML radon exposure and test facility in May 1996. In total, thirty-four government, private and academic facilities participated in the exercise with over 170 passive and electronic devices exposed in the EML test chamber. During the first week of the exercise, passive and continuous measuring devices were exposed (usually in quadruplicate) to about 1,280 Bq m{sup {minus}3} {sup 222}Rn for 1--7 days. Radon progeny measurements were made during the second week of the exercise. The results indicate thatmore » all of the tested devices that measure radon gas performed well and fulfill their intended purpose. The grand mean (GM) ratio of the participants` reported values to the EML values, for all four radon device categories, was 0.99 {plus_minus} 0.08. Eighty-five percent of all the radon measuring devices that were exposed in the EML radon test chamber were within {plus_minus}1 standard deviation (SD) of the EML reference values. For the most part, radon progeny measurements were also quite good as compared to the EML values. The GM ratio for the 10 continuous PAEC instruments was 0.90 {plus_minus} 0.12 with 75% of the devices within 1 SD of the EML reference values. Most of the continuous and integrating electronic instruments used for measuring the PAEC underestimated the EML values by about 10--15% probably because the concentration of particles onto which the radon progeny were attached was low (1,200--3,800 particles cm{sup {minus}3}). The equilibrium factor at that particle concentration level was 0.10--0.22.« less

  15. Reference standards for body fat measures using GE dual energy x-ray absorptiometry in Caucasian adults.

    PubMed

    Imboden, Mary T; Welch, Whitney A; Swartz, Ann M; Montoye, Alexander H K; Finch, Holmes W; Harber, Matthew P; Kaminsky, Leonard A

    2017-01-01

    Dual energy x-ray absorptiometry (DXA) is an established technique for the measurement of body composition. Reference values for these variables, particularly those related to fat mass, are necessary for interpretation and accurate classification of those at risk for obesity-related health complications and in need of lifestyle modifications (diet, physical activity, etc.). Currently, there are no reference values available for GE-Healthcare DXA systems and it is known that whole-body and regional fat mass measures differ by DXA manufacturer. To develop reference values by age and sex for DXA-derived fat mass measurements with GE-Healthcare systems. A de-identified sample of 3,327 participants (2,076 women, 1,251 men) was obtained from Ball State University's Clinical Exercise Physiology Laboratory and University of Wisconsin-Milwaukee's Physical Activity & Health Research Laboratory. All scans were completed using a GE Lunar Prodigy or iDXA and data reported included percent body fat (%BF), fat mass index (FMI), and ratios of android-to-gynoid (A/G), trunk/limb, and trunk/leg fat measurements. Percentiles were calculated and a factorial ANOVA was used to determine differences in the mean values for each variable between age and sex. Normative reference values for fat mass variables from DXA measurements obtained from GE-Healthcare DXA systems are presented as percentiles for both women and men in 10-year age groups. Women had higher (p<0.01) mean %BF and FMI than men, whereas men had higher (p<0.01) mean ratios of A/G, trunk/limb, and trunk/leg fat measurements than women. These reference values provide clinicians and researchers with a resource for interpretation of DXA-derived fat mass measurements specific to use with GE-Healthcare DXA systems.

  16. Biomarkers Predictive of Exacerbations in the SPIROMICS and COPDGene Cohorts

    PubMed Central

    Keene, Jason D.; Jacobson, Sean; Kechris, Katerina; Kinney, Gregory L.; Foreman, Marilyn G.; Doerschuk, Claire M.; Make, Barry J.; Curtis, Jeffrey L.; Rennard, Stephen I.; Barr, R. Graham; Bleecker, Eugene R.; Kanner, Richard E.; Kleerup, Eric C.; Hansel, Nadia N.; Woodruff, Prescott G.; Han, MeiLan K.; Paine, Robert; Martinez, Fernando J.; O’Neal, Wanda K.

    2017-01-01

    Rationale: Chronic obstructive pulmonary disease exacerbations are associated with disease progression, higher healthcare cost, and increased mortality. Published predictors of future exacerbations include previous exacerbation, airflow obstruction, poor overall health, home oxygen use, and gastroesophageal reflux. Objectives: To determine the value of adding blood biomarkers to clinical variables to predict exacerbations. Methods: Subjects from the SPIROMICS (Subpopulations and Intermediate Outcomes Measures in COPD Study) (n = 1,544) and COPDGene (Genetic Epidemiology of COPD) (n = 602) cohorts had 90 plasma or serum candidate proteins measured on study entry using Myriad-RBM multiplex panels. We defined total exacerbations as subject-reported worsening in respiratory health requiring therapy with corticosteroids and/or antibiotics, and severe exacerbations as those leading to hospitalizations or emergency room visits. We assessed retrospective exacerbations during the 12 months before enrollment and then documented prospective exacerbations in each cohort. Exacerbations were modeled for biomarker associations with negative binomial regression including clinical covariates (age, sex, percent predicted FEV1, self-reported gastroesophageal reflux, St. George’s Respiratory Questionnaire score, smoking status). We used the Stouffer-Liptak test to combine P values for metaanalysis. Measurements and Main Results: Between the two cohorts, 3,471 total exacerbations (1,044 severe) were reported. We identified biomarkers within each cohort that were significantly associated with a history of exacerbation and with a future exacerbation, but there was minimal replication between the cohorts. Although established clinical features were predictive of exacerbations, of the blood biomarkers only decorin and α2-macroglobulin increased predictive value for future severe exacerbations. Conclusions: Blood biomarkers were significantly associated with the occurrence of exacerbations but were not robust between cohorts and added little to the predictive value of clinical covariates for exacerbations. PMID:27579823

  17. Strategy of investment in electricity sources--Market value of a power plant and the electricity market

    NASA Astrophysics Data System (ADS)

    Bartnik, R.; Hnydiuk-Stefan, A.; Buryn, Z.

    2017-11-01

    This paper reports the results of the investment strategy analysis in different electricity sources. New methodology and theory of calculating the market value of the power plant and value of the electricity market supplied by it are presented. The financial gain forms the most important criteria in the assessment of an investment by an investor. An investment strategy has to involve a careful analysis of each considered project in order that the right decision and selection will be made while various components of the projects will be considered. The latter primarily includes the aspects of risk and uncertainty. Profitability of an investment in the electricity sources (as well as others) is offered by the measures applicable for the assessment of the economic effectiveness of an investment based on calculations e.g. power plant market value and the value of the electricity that is supplied by a power plant. The values of such measures decide on an investment strategy in the energy sources. This paper contains analysis of exemplary calculations results of power plant market value and the electricity market value supplied by it.

  18. Earnings Quality Measures and Excess Returns

    PubMed Central

    Perotti, Pietro; Wagenhofer, Alfred

    2014-01-01

    This paper examines how commonly used earnings quality measures fulfill a key objective of financial reporting, i.e., improving decision usefulness for investors. We propose a stock-price-based measure for assessing the quality of earnings quality measures. We predict that firms with higher earnings quality will be less mispriced than other firms. Mispricing is measured by the difference of the mean absolute excess returns of portfolios formed on high and low values of a measure. We examine persistence, predictability, two measures of smoothness, abnormal accruals, accruals quality, earnings response coefficient and value relevance. For a large sample of US non-financial firms over the period 1988–2007, we show that all measures except for smoothness are negatively associated with absolute excess returns, suggesting that smoothness is generally a favorable attribute of earnings. Accruals measures generate the largest spread in absolute excess returns, followed by smoothness and market-based measures. These results lend support to the widespread use of accruals measures as overall measures of earnings quality in the literature. PMID:26300582

  19. Earnings Quality Measures and Excess Returns.

    PubMed

    Perotti, Pietro; Wagenhofer, Alfred

    2014-06-01

    This paper examines how commonly used earnings quality measures fulfill a key objective of financial reporting, i.e., improving decision usefulness for investors. We propose a stock-price-based measure for assessing the quality of earnings quality measures. We predict that firms with higher earnings quality will be less mispriced than other firms. Mispricing is measured by the difference of the mean absolute excess returns of portfolios formed on high and low values of a measure. We examine persistence, predictability, two measures of smoothness, abnormal accruals, accruals quality, earnings response coefficient and value relevance. For a large sample of US non-financial firms over the period 1988-2007, we show that all measures except for smoothness are negatively associated with absolute excess returns, suggesting that smoothness is generally a favorable attribute of earnings. Accruals measures generate the largest spread in absolute excess returns, followed by smoothness and market-based measures. These results lend support to the widespread use of accruals measures as overall measures of earnings quality in the literature.

  20. Variability in Effective Radiating Area and Output Power of New Ultrasound Transducers at 3 MHz

    PubMed Central

    Johns, Lennart D; Straub, Stephen J; Howard, Samuel M

    2007-01-01

    Context: Spatial average intensity (SAI) is often used by clinicians to gauge therapeutic ultrasound dosage, yet SAI measures are not directly regulated by US Food and Drug Administration (FDA) standards. Current FDA guidelines permit a possible 50% to 150% minimum to maximum range of SAI values, potentially contributing to variability in clinical outcomes. Objective: To measure clinical values that describe ultrasound transducers and to determine the degree of intramanufacturer and intermanufacturer variability in effective radiating area, power, and SAI when the transducer is functioning at 3 MHz. Design: A descriptive and interferential approach was taken to this quasi-experimental design. Setting: Measurement laboratory. Patients or Other Participants: Sixty-six 5-cm2 ultrasound transducers were purchased from 6 different manufacturers. Intervention(s): All transducers were calibrated and then assessed using standardized measurement techniques; SAI was normalized to account for variability in effective radiating area, resulting in an nSAI. Main Outcome Measure(s): Effective radiating area, power, and nSAI. Results: All manufacturers with the exception of Omnisound (P = .534) showed a difference between the reported and measured effective radiating area values (P < .001). All transducers were within FDA guidelines for power (±20%). Chattanooga (0.85 ± 0.05 W/cm2) had a lower nSAI (P < .05) than all other manufacturers functioning at 3 MHz. Intramanufacturer variability in SAI ranged from 16% to 35%, and intermanufacturer variability ranged from 22% to 61%. Conclusions: Clinicians should consider treatment values of each individual transducer, regardless of the manufacturer. In addition, clinicians should scrutinize the power calibration and recalibration record of the transducer and adjust clinical settings as needed for the desired level of heating. Our data may aid in explaining the reported heating differences among transducers from different manufacturers. Stricter FDA standards regarding effective radiating area and total power are needed, and standards regulating SAI should be established. PMID:17597939

  1. Effect of pH on the Electrophoretic Mobility of Spores of Bacillus anthracis and Its Surrogates in Aqueous Solutions

    EPA Science Inventory

    Electrophoretic mobility (EPM) of endospores of Bacillus anthracis and surrogates were measured in aqueous solution across a broad pH range and several ionic strengths. EPM values trended around phylogenetic clustering based on the 16S rRNA gene. Measurements reported here prov...

  2. Misconceptions of Selected Science Concepts Held by Elementary School Students

    ERIC Educational Resources Information Center

    Doran, Rodney L.

    1972-01-01

    Describes a test, administered as a motion picture, designed to measure misconceptions about the particle model of matter held by students in grades two through six. Reliability values for tests of eight misconceptions are given and the correlations of misconception scores with measures of IQ, reading, mathematics, and science ability reported.…

  3. Comparative Performance Data for Critical Access Hospitals

    ERIC Educational Resources Information Center

    Pink, George H.; Slifkin, Rebecca T.; Coburn, Andrew F.; Gale, John A.

    2004-01-01

    Context: Among small rural hospitals, there is a growing recognition of the need to measure and report on the use of resources and the safety and quality of the services provided. Dashboards, clinical value compasses, and balanced scorecards are approaches to performance measurement that have been adopted by many health care organizations.…

  4. Scanning confocal slit photon counter measurements of post-PRK haze in two-year study

    NASA Astrophysics Data System (ADS)

    Taboada, John; Gaines, David; Perez, Mary A.; Waller, Steve G.; Ivan, Douglas J.; Baldwin, J. Bruce; LoRusso, Frank; Tutt, Ronald C.; Thompson, B.; Perez, Jose; Tredici, Thomas; Johnson, Dan A.

    2001-06-01

    In our study, a group of 80 United States Air Force, non- flying personnel will undergo photorefractive corneal surgery for moderate levels of myopia (< 6 diopters) and 20 will serve as controls. As of this report, approximately 56 have had the treatment. Of these, only about 59% of the treated eyes showed even a trace (.5) level of clinically assessed haze at any time. We report on the use of a recently developed instrument designed for the objective measurement of these low levels of haze in treated corneas. The sensitivity of the instrument is derived from the use of a scanning confocal slit photon counter. The use of a physical standard for calibration secures accuracy and reproducibility over an extensive period of time. Our haze measurements in this study revealed a very low level increase from baseline values for these patients. The typical increase over baseline was of the same magnitude as the variability in the observations, although the inherent variability in the measurements was approximately 0.25 times the value of the patient's haze variability.

  5. A novel inverse method for determining the refractive indices of medium and dispersed particles simultaneously by turbidity measurement.

    PubMed

    Xu, Shenghua; Liu, Jie; Sun, Zhiwei; Zhang, Pu

    2008-10-01

    The refractive indices of particles and dispersion medium are important parameters in many colloidal experiments using optical techniques, such as turbidity and light scattering measurements. These data are in general wavelength-dependent and may not be available at some wavelengths fitting to the experimental requirement. In this study we present a novel approach to inversely determine the refractive indices of particles and dispersion medium by examining the consistency of measured extinction cross sections of particles with their theoretical values using a series of trial values of the refractive indices. The colloidal suspension of polystyrene particles dispersed in water was used as an example to demonstrate how this approach works and the data obtained via such a method are compared with those reported in literature, showing a good agreement between both. Furthermore, the factors that affect the accuracy of measurements are discussed. We also present some data of the refractive indices of polystyrene over a range of wavelengths smaller than 400 nm that have been not reported in the available literature.

  6. Measurement of viscosity of gaseous mixtures at atmospheric pressure

    NASA Technical Reports Server (NTRS)

    Singh, J. J.; Mall, G. H.; Chegini, H.

    1986-01-01

    Coefficients of viscosity of various types of gas mixtures, including simulated natural-gas samples, have been measured at atmospheric pressure and room temperature using a modified capillary tube method. Pressure drops across the straight capillary tube section of a thermal mass flowmeter were measured for small, well-defined, volume flow rates for the test gases and for standard air. In this configuration, the flowmeter provides the volumetric flow rates as well as a well-characterized capillary section for differential pressure measurements across it. The coefficients of viscosity of the test gases were calculated using the reported value of 185.6 micro P for the viscosity of air. The coefficients of viscosity for the test mixtures were also calculated using Wilke's approximation of the Chapman-Enskog (C-E) theory. The experimental and calculated values for binary mixtures are in agreement within the reported accuracy of Wilke's approximation of the C-E theory. However, the agreement for multicomponent mixtures is less satisfactory, possible because of the limitations of Wilkes's approximation of the classical dilute-gas state model.

  7. The usefulness of "corrected" body mass index vs. self-reported body mass index: comparing the population distributions, sensitivity, specificity, and predictive utility of three correction equations using Canadian population-based data.

    PubMed

    Dutton, Daniel J; McLaren, Lindsay

    2014-05-06

    National data on body mass index (BMI), computed from self-reported height and weight, is readily available for many populations including the Canadian population. Because self-reported weight is found to be systematically under-reported, it has been proposed that the bias in self-reported BMI can be corrected using equations derived from data sets which include both self-reported and measured height and weight. Such correction equations have been developed and adopted. We aim to evaluate the usefulness (i.e., distributional similarity; sensitivity and specificity; and predictive utility vis-à-vis disease outcomes) of existing and new correction equations in population-based research. The Canadian Community Health Surveys from 2005 and 2008 include both measured and self-reported values of height and weight, which allows for construction and evaluation of correction equations. We focused on adults age 18-65, and compared three correction equations (two correcting weight only, and one correcting BMI) against self-reported and measured BMI. We first compared population distributions of BMI. Second, we compared the sensitivity and specificity of self-reported BMI and corrected BMI against measured BMI. Third, we compared the self-reported and corrected BMI in terms of association with health outcomes using logistic regression. All corrections outperformed self-report when estimating the full BMI distribution; the weight-only correction outperformed the BMI-only correction for females in the 23-28 kg/m2 BMI range. In terms of sensitivity/specificity, when estimating obesity prevalence, corrected values of BMI (from any equation) were superior to self-report. In terms of modelling BMI-disease outcome associations, findings were mixed, with no correction proving consistently superior to self-report. If researchers are interested in modelling the full population distribution of BMI, or estimating the prevalence of obesity in a population, then a correction of any kind included in this study is recommended. If the researcher is interested in using BMI as a predictor variable for modelling disease, then both self-reported and corrected BMI result in biased estimates of association.

  8. Event- and interval-based measurement of stuttering: a review.

    PubMed

    Valente, Ana Rita S; Jesus, Luis M T; Hall, Andreia; Leahy, Margaret

    2015-01-01

    Event- and interval-based measurements are two different ways of computing frequency of stuttering. Interval-based methodology emerged as an alternative measure to overcome problems associated with reproducibility in the event-based methodology. No review has been made to study the effect of methodological factors in interval-based absolute reliability data or to compute the agreement between the two methodologies in terms of inter-judge, intra-judge and accuracy (i.e., correspondence between raters' scores and an established criterion). To provide a review related to reproducibility of event-based and time-interval measurement, and to verify the effect of methodological factors (training, experience, interval duration, sample presentation order and judgment conditions) on agreement of time-interval measurement; in addition, to determine if it is possible to quantify the agreement between the two methodologies The first two authors searched for articles on ERIC, MEDLINE, PubMed, B-on, CENTRAL and Dissertation Abstracts during January-February 2013 and retrieved 495 articles. Forty-eight articles were selected for review. Content tables were constructed with the main findings. Articles related to event-based measurements revealed values of inter- and intra-judge greater than 0.70 and agreement percentages beyond 80%. The articles related to time-interval measures revealed that, in general, judges with more experience with stuttering presented significantly higher levels of intra- and inter-judge agreement. Inter- and intra-judge values were beyond the references for high reproducibility values for both methodologies. Accuracy (regarding the closeness of raters' judgements with an established criterion), intra- and inter-judge agreement were higher for trained groups when compared with non-trained groups. Sample presentation order and audio/video conditions did not result in differences in inter- or intra-judge results. A duration of 5 s for an interval appears to be an acceptable agreement. Explanation for high reproducibility values as well as parameter choice to report those data are discussed. Both interval- and event-based methodologies used trained or experienced judges for inter- and intra-judge determination and data were beyond the references for good reproducibility values. Inter- and intra-judge values were reported in different metric scales among event- and interval-based methods studies, making it unfeasible to quantify the agreement between the two methods. © 2014 Royal College of Speech and Language Therapists.

  9. Looking Under the Streetlight? A Framework for Differentiating Performance Measures by Level of Care in a Value-Based Payment Environment

    PubMed Central

    Van Such, Monica B.; Nesse, Robert E.; Dilling, James A.; Swensen, Stephen J.; Thompson, Kristine M.; Orlowski, Janis M.; Santrach, Paula J.

    2017-01-01

    The majority of quality measures used to assess providers and hospitals are based on easily obtained data, focused on a few dimensions of quality, and developed mainly for primary/community care and population health. While this approach supports efforts focused on addressing the triple aim of health care, many current quality report cards and assessments do not reflect the breadth or complexity of many referral center practices. In this article, the authors highlight the differences between population health efforts and referral care and address issues related to value measurement and performance assessment. They discuss why measures may need to differ across the three levels of care (primary/community care, secondary care, complex care) and illustrate the need for further risk adjustment to eliminate referral bias. With continued movement toward value-based purchasing, performance measures and reimbursement schemes need to reflect the increased level of intensity required to provide complex care. The authors propose a framework to operationalize value measurement and payment for specialty care, and they make specific recommendations to improve performance measurement for complex patients. Implementing such a framework to differentiate performance measures by level of care involves coordinated efforts to change both policy and operational platforms. An essential component of this framework is a new model that defines the characteristics of patients who require complex care and standardizes metrics that incorporate those definitions. PMID:28353502

  10. Looking Under the Streetlight? A Framework for Differentiating Performance Measures by Level of Care in a Value-Based Payment Environment.

    PubMed

    Naessens, James M; Van Such, Monica B; Nesse, Robert E; Dilling, James A; Swensen, Stephen J; Thompson, Kristine M; Orlowski, Janis M; Santrach, Paula J

    2017-07-01

    The majority of quality measures used to assess providers and hospitals are based on easily obtained data, focused on a few dimensions of quality, and developed mainly for primary/community care and population health. While this approach supports efforts focused on addressing the triple aim of health care, many current quality report cards and assessments do not reflect the breadth or complexity of many referral center practices.In this article, the authors highlight the differences between population health efforts and referral care and address issues related to value measurement and performance assessment. They discuss why measures may need to differ across the three levels of care (primary/community care, secondary care, complex care) and illustrate the need for further risk adjustment to eliminate referral bias.With continued movement toward value-based purchasing, performance measures and reimbursement schemes need to reflect the increased level of intensity required to provide complex care. The authors propose a framework to operationalize value measurement and payment for specialty care, and they make specific recommendations to improve performance measurement for complex patients. Implementing such a framework to differentiate performance measures by level of care involves coordinated efforts to change both policy and operational platforms. An essential component of this framework is a new model that defines the characteristics of patients who require complex care and standardizes metrics that incorporate those definitions.

  11. Measuring Nursing Value from the Electronic Health Record.

    PubMed

    Welton, John M; Harper, Ellen M

    2016-01-01

    We report the findings of a big data nursing value expert group made up of 14 members of the nursing informatics, leadership, academic and research communities within the United States tasked with 1. Defining nursing value, 2. Developing a common data model and metrics for nursing care value, and 3. Developing nursing business intelligence tools using the nursing value data set. This work is a component of the Big Data and Nursing Knowledge Development conference series sponsored by the University Of Minnesota School Of Nursing. The panel met by conference calls for fourteen 1.5 hour sessions for a total of 21 total hours of interaction from August 2014 through May 2015. Primary deliverables from the bit data expert group were: development and publication of definitions and metrics for nursing value; construction of a common data model to extract key data from electronic health records; and measures of nursing costs and finance to provide a basis for developing nursing business intelligence and analysis systems.

  12. Chemical Composition Measurements of LAWA44 Glass Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fox, K.; Edwards, T.; Riley, W.

    2016-11-15

    DOE is building the Hanford Tank Waste Treatment and Immobilization Plant (WTP) at the Hanford Site in Washington to remediate 55 million gallons of radioactive waste that is temporarily stored in 177 underground tanks. Both low-activity and high-level wastes will then be vitrified into borosilicate glass using Joule-heated ceramic melters. Efforts are being made to increase the loading of Hanford tank wastes in the glass. One area of work is enhancing waste glass composition/property models and broadening the compositional regions over which those models are applicable. In this report, the Savannah River National Laboratory provides chemical analysis results for severalmore » samples of a simulated low-activity waste glass, LAWA44, provided by the Pacific Northwest National Laboratory as part of an ongoing development task. The measured chemical composition data are reported and compared with the targeted values for each component for each glass. A detailed review showed no indications of errors in the preparation or measurement of the study glasses. All of the measured sums of oxides for the study glasses fell within the interval of 97.9 to 102.6 wt %, indicating acceptable recovery of the glass components. Comparisons of the targeted and measured chemical compositions showed that the measured values for the glasses met the targeted concentrations within 10% for those components present at more than 5 wt %. It was noted that the measured B 2O 3 concentrations are somewhat above the targeted values for the study glasses. No obvious trends were observed with regard to the multiple melting steps used to prepare the study glasses, indicating that any potential effects of volatility were below measurable thresholds.« less

  13. Electric Monopole Transition Strengths in 62Ni

    NASA Astrophysics Data System (ADS)

    Evitts, L. J.; Garnsworthy, A. B.; Kibédi, T.; Moukaddam, M.; Alshahrani, B.; Eriksen, T. K.; Holt, J. D.; Hota, S. S.; Lane, G. J.; Lee, B. Q.; McCormick, B. P.; Palalani, N.; Reed, M. W.; Stroberg, S. R.; Stuchbery, A. E.

    2016-09-01

    Excited states in 62Ni were populated with a (p, p') reaction using the 14UD Pelletron accelerator at the Australian National University. Electric monopole transition strengths, ρ2(E0), were measured through simultaneous detection of the internal conversion electrons and γ rays emitted from the de-excitation of populated states, using the Super-e spectrometer coupled with a germanium detector. The strength of the 02+ to 01+ transition has been measured to be 77-34+23 × 10-3 and agrees with previously reported values. Upper limits have been placed on the 03+ to 01+ and 03+ to 02+ transitions. The measured ρ2(E0) value of the 22+ to 21+ transition in 62Ni has been measured for the first time and found to be one of the largest ρ2(E0) values measured to date in nuclei heavier than Ca. The low-lying states of 62Ni have previously been classified as one- and two-phonon vibrational states based on level energies. The measured electric quadrupole transition strengths are consistent with this interpretation. However as electric monopole transitions are forbidden between states which differ by one phonon number, the simple harmonic quadrupole vibrational picture is not suffcient to explain the large ρ2(E0) value for the 22+ to 21+ transition.

  14. A comparison of measured versus self-reported anthropometrics for assessing obesity in adults: a literature review.

    PubMed

    Maukonen, Mirkka; Männistö, Satu; Tolonen, Hanna

    2018-03-01

    Up-to-date information on the accuracy between different anthropometric data collection methods is vital for the reliability of anthropometric data. A previous review on this matter was conducted a decade ago. Our aim was to conduct a literature review on the accuracy of self-reported height, weight, and body mass index (BMI) against measured values for assessing obesity in adults. To obtain an overview of the present situation, we included studies published after the previous review. Differences according to sex, BMI groups, and continents were also assessed. Studies published between January 2006 and April 2017 were identified from a literature search on PubMed. Our search retrieved 62 publications on adult populations that showed a tendency for self-reported height to be overestimated and weight to be underestimated when compared with measured values. The findings were similar for both sexes. BMI derived from self-reported height and weight was underestimated; there was a clear tendency for underestimation of overweight (from 1.8%-points to 9.8%-points) and obesity (from 0.7%-points to 13.4%-points) prevalence by self-report. The bias was greater in overweight and obese participants than those of normal weight. Studies conducted in North America showed a greater bias, whereas the bias in Asian studies seemed to be lower than those from other continents. With globally rising obesity rates, accurate estimation of obesity is essential for effective public health policies to support obesity prevention. As self-report bias tends to be higher among overweight and obese individuals, measured anthropometrics provide a more reliable tool for assessing the prevalence of obesity.

  15. Compilation of VS30 Data for the United States

    USGS Publications Warehouse

    Yong, Alan; Thompson, Eric M.; Wald, David J.; Knudsen, Keith L.; Odum, Jack K.; Stephenson, William J.; Haefner, Scott

    2016-01-01

    VS30, the time-averaged shear-wave velocity (VS) to a depth of 30 meters, is a key index adopted by the earthquake engineering community to account for seismic site conditions. VS30 is typically based on geophysical measurements of VS derived from invasive and noninvasive techniques at sites of interest. Owing to cost considerations, as well as logistical and environmental concerns, VS30 data are sparse or not readily available for most areas. Where data are available, VS30 values are often assembled in assorted formats that are accessible from disparate and (or) impermanent Web sites. To help remedy this situation, we compiled VS30 measurements obtained by studies funded by the U.S. Geological Survey (USGS) and other governmental agencies. Thus far, we have compiled VS30 values for 2,997 sites in the United States, along with metadata for each measurement from government-sponsored reports, Web sites, and scientific and engineering journals. Most of the data in our VS30 compilation originated from publications directly reporting the work of field investigators. A small subset (less than 20 percent) of VS30 values was previously compiled by the USGS and other research institutions. Whenever possible, VS30 originating from these earlier compilations were crosschecked against published reports. Both downhole and surface-based VS30 estimates are represented in our VS30 compilation. Most of the VS30 data are for sites in the western contiguous United States (2,141 sites), whereas 786 VS30 values are for sites in the Central and Eastern United States; 70 values are for sites in other parts of the United States, including Alaska (15 sites), Hawaii (30 sites), and Puerto Rico (25 sites). An interactive map is hosted on the primary USGS Web site for accessing VS30 data (http://earthquake.usgs.gov/research/vs30/).

  16. Anomalous effects of radioactive decay rates and capacitance values measured inside a modified Faraday cage: Correlations with space weather

    NASA Astrophysics Data System (ADS)

    Scholkmann, F.; Milián-Sánchez, V.; Mocholí-Salcedo, A.; Milián, C.; Kolombet, V. A.; Verdú, G.

    2017-03-01

    Recently we reported (Milián-Sánchez V. et al., Nucl. Instrum. Methods A, 828 (2016) 210) our experimental results involving 226Ra decay rate and capacitance measurements inside a modified Faraday cage. Our measurements exhibited anomalous effects of unknown origin. In this letter we report new results regarding our investigation into the origins of the observed effects. We report preliminary findings of a correlation analysis between the radioactive decay rates and capacitance time series and space weather related variables (geomagnetic field disturbances and cosmic-ray neutron counts). A significant correlation was observed for specific data sets. The results are presented and possible implications for future work discussed.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, L.R.

    Much research has been devoted to measurement of total blood volume (TBV) and cardiac output (CO) in humans but not enough effort has been devoted to collection and reduction of results for the purpose of deriving typical or {open_quotes}reference{close_quotes} values. Identification of normal values for TBV and CO is needed not only for clinical evaluations but also for the development of biokinetic models for ultra-short-lived radionuclides used in nuclear medicine (Leggett and Williams 1989). The purpose of this report is to offer reference values for TBV and CO, along with estimates of the associated uncertainties that arise from intra- andmore » inter-subject variation, errors in measurement techniques, and other sources. Reference values are derived for basal supine CO and TBV in reference adult humans, and differences associated with age, sex, body size, body position, exercise, and other circumstances are discussed.« less

  18. Elastic Moduli of Pyrolytic Boron Nitride Measured Using 3-Point Bending and Ultrasonic Testing

    NASA Technical Reports Server (NTRS)

    Kaforey, M. L.; Deeb, C. W.; Matthiesen, D. H.; Roth, D. J.

    1999-01-01

    Three-point bending and ultrasonic testing were performed on a flat plate of PBN. In the bending experiment, the deformation mechanism was believed to be shear between the pyrolytic layers, which yielded a shear modulus, c (sub 44), of 2.60 plus or minus .31 GPa. Calculations based on the longitudinal and shear wave velocity measurements yielded values of 0.341 plus or minus 0.006 for Poisson's ratio, 10.34 plus or minus .30 GPa for the elastic modulus (c (sub 33)), and 3.85 plus or minus 0.02 GPa for the shear modulus (c (sub 44)). Since free basal dislocations have been reported to affect the value of c (sub 44) found using ultrasonic methods, the value from the bending experiment was assumed to be the more accurate value.

  19. CCQM-K90, formaldehyde in nitrogen, 2 μmol mol-1 Final report

    NASA Astrophysics Data System (ADS)

    Viallon, Joële; Flores, Edgar; Idrees, Faraz; Moussay, Philippe; Wielgosz, Robert Ian; Kim, D.; Kim, Y. D.; Lee, S.; Persijn, S.; Konopelko, L. A.; Kustikov, Y. A.; Malginov, A. V.; Chubchenko, I. K.; Klimov, A. Y.; Efremova, O. V.; Zhou, Z.; Possolo, A.; Shimosaka, T.; Brewer, P.; Macé, T.; Ferracci, Valerio; Brown, Richard J. C.; Aoki, Nobuyuki

    2017-01-01

    The CCQM-K90 comparison is designed to evaluate the level of comparability of national metrology institutes (NMI) or designated institutes (DI) measurement capabilities for formaldehyde in nitrogen at a nominal mole fraction of 2 μmol mol-1. The comparison was organised by the BIPM using a suite of gas mixtures prepared by a producer of specialty calibration gases. The BIPM assigned the formaldehyde mole fraction in the mixtures by comparison with primary mixtures generated dynamically by permeation coupled with continuous weighing in a magnetic suspension balance. The BIPM developed two dynamic sources of formaldehyde in nitrogen that provide two independent values of the formaldehyde mole fraction: the first one based on diffusion of trioxane followed by thermal conversion to formaldehyde, the second one based on permeation of formaldehyde from paraformaldehyde contained in a permeation tube. Two independent analytical methods, based on cavity ring down spectroscopy (CRDS) and Fourier transform infrared spectroscopy (FTIR) were used for the assignment procedure. Each participating institute was provided with one transfer standard and value assigned the formaldehyde mole fraction in the standard based on its own measurement capabilities. The stability of the formaldehyde mole fraction in transfer standards was deduced from repeated measurements performed at the BIPM before and after measurements performed at participating institutes. In addition, 5 control standards were kept at the BIPM for regular measurements during the course of the comparison. Temporal trends that approximately describe the linear decrease of the amount-of-substance fraction of formaldehyde in nitrogen in the transfer standards over time were estimated by two different mathematical treatments, the outcomes of which were proposed to participants. The two treatments also differed in the way measurement uncertainties arising from measurements performed at the BIPM were propagated to the uncertainty of the trend parameters, as well as how the dispersion of the dates when measurements were made by the participants was taken into account. Upon decision of the participants, the Key Comparison Reference Values were assigned by the BIPM using the largest uncertainty for measurements performed at the BIPM, linear regression without weight to calculate the trend parameters, and not taking into account the dispersion of dates for measurements made by the participant. Each transfer standard was assigned its own reference value and associated expanded uncertainty. An expression for the degree of equivalence between each participating institute and the KCRV was calculated from the comparison results and measurement uncertainties submitted by participating laboratories. Results of the alternative mathematical treatment are presented in annex of this report. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Thoughts on Earned Value Assessments

    NASA Technical Reports Server (NTRS)

    Pido, Kelle

    2009-01-01

    This slide presentation reviews the concepts of Earned Value reporting and Earned Value Metrics (EVM) and the implementation for the Constellation Program. EVM is used to manage both the contract and civil service workforce, and used as a measure of contractor costs and performance. The Program EVM is not as useful for Level of Effort tasking, for either contractor, or civil service employees. Some issues and concerns in reference to EVM and the process for the use of EVM for Mission assurance are reviewed,

  1. [Postpartal ovarian thrombophlebitis. Value of Doppler ultrasonograph y].

    PubMed

    Renaud-Giono, A; Giraud, J R; Poulain, P; Proudhon, J F; Grall, J Y; Moquet, P Y; Darnault, J P

    1996-01-01

    Thrombophlebitis of the ovarian vein is a well recognized but uncommon complication during the postpartum period. We report a small series and emphasize the contribution of color Doppler and the basic therapeutic measures.

  2. Laser Speckle Rheology for evaluating the viscoelastic properties of hydrogel scaffolds

    PubMed Central

    Hajjarian, Zeinab; Nia, Hadi Tavakoli; Ahn, Shawn; Grodzinsky, Alan J.; Jain, Rakesh K.; Nadkarni, Seemantini K.

    2016-01-01

    Natural and synthetic hydrogel scaffolds exhibit distinct viscoelastic properties at various length scales and deformation rates. Laser Speckle Rheology (LSR) offers a novel, non-contact optical approach for evaluating the frequency-dependent viscoelastic properties of hydrogels. In LSR, a coherent laser beam illuminates the specimen and a high-speed camera acquires the time-varying speckle images. Cross-correlation analysis of frames returns the speckle intensity autocorrelation function, g2(t), from which the frequency-dependent viscoelastic modulus, G*(ω), is deduced. Here, we establish the capability of LSR for evaluating the viscoelastic properties of hydrogels over a large range of moduli, using conventional mechanical rheometry and atomic force microscopy (AFM)-based indentation as reference-standards. Results demonstrate a strong correlation between |G*(ω)| values measured by LSR and mechanical rheometry (r = 0.95, p < 10−9), and z-test analysis reports that moduli values measured by the two methods are identical (p > 0.08) over a large range (47 Pa – 36 kPa). In addition, |G*(ω)| values measured by LSR correlate well with indentation moduli, E, reported by AFM (r = 0.92, p < 10−7). Further, spatially-resolved moduli measurements in micro-patterned substrates demonstrate that LSR combines the strengths of conventional rheology and micro-indentation in assessing hydrogel viscoelastic properties at multiple frequencies and small length-scales. PMID:27905494

  3. Laser Speckle Rheology for evaluating the viscoelastic properties of hydrogel scaffolds.

    PubMed

    Hajjarian, Zeinab; Nia, Hadi Tavakoli; Ahn, Shawn; Grodzinsky, Alan J; Jain, Rakesh K; Nadkarni, Seemantini K

    2016-12-01

    Natural and synthetic hydrogel scaffolds exhibit distinct viscoelastic properties at various length scales and deformation rates. Laser Speckle Rheology (LSR) offers a novel, non-contact optical approach for evaluating the frequency-dependent viscoelastic properties of hydrogels. In LSR, a coherent laser beam illuminates the specimen and a high-speed camera acquires the time-varying speckle images. Cross-correlation analysis of frames returns the speckle intensity autocorrelation function, g 2 (t), from which the frequency-dependent viscoelastic modulus, G*(ω), is deduced. Here, we establish the capability of LSR for evaluating the viscoelastic properties of hydrogels over a large range of moduli, using conventional mechanical rheometry and atomic force microscopy (AFM)-based indentation as reference-standards. Results demonstrate a strong correlation between |G*(ω)| values measured by LSR and mechanical rheometry (r = 0.95, p < 10 -9 ), and z-test analysis reports that moduli values measured by the two methods are identical (p > 0.08) over a large range (47 Pa - 36 kPa). In addition, |G*(ω)| values measured by LSR correlate well with indentation moduli, E, reported by AFM (r = 0.92, p < 10 -7 ). Further, spatially-resolved moduli measurements in micro-patterned substrates demonstrate that LSR combines the strengths of conventional rheology and micro-indentation in assessing hydrogel viscoelastic properties at multiple frequencies and small length-scales.

  4. Comparing Assay Performance of ELISA and Chemiluminescence Immunoassay in Detecting Antibodies to Hepatitis B Surface Antigen

    PubMed Central

    Sagar, Siddharth; Vishwanath, Shashidhar; Banerjee, Barnini; Eshwara, Vandana Kalwaje; Chawla, Kiran

    2016-01-01

    Introduction Antibodies to Hepatitis B surface Antigen (Anti-HBs) levels are measured as markers for immune response to vaccination and in decision making for post-exposure prophylaxis against Hepatitis-B. Several immunoassay formats are used to measure Anti-HBs, thus carrying the possibility of variation in measured levels between different assays. This study compares the performance of Chemiluminescence Immunoassay (CLIA) against Enzyme-linked Immunosorbent Assay (ELISA) in measuring Anti-HBs titer by looking into concordance between the two test reports. Aim To compare the agreement between ELISA and CLIA in measurement of Anti–HBs antibody titers. Materials and Methods This prospective comparative study conducted at Kasturba Medical College, Manipal measured consecutive serum samples (69) sent for anti-HBs levels during May-June 2016 using both CLIA (Abbott Architect) and ELISA (Bio-Rad). Anti-HBs values of ≤10mIU/ml was considered as non-protective and >10mIU/ml as protective. The agreement between the tests in classifying the antibody titers as non-protective or protective was computed using Kappa coefficient, and the difference in individual titer values between the tests compared using Bland-Altman plot on SPSS (v.15). Results Out of the 69 samples analysed, 18 samples (26.1%) were of health-care personnel and remaining of patients. Agreement between ELISA and CLIA in identifying the antibody titers as protective and non-protective were 96.5% and 90.9% respectively, resulting in an agreement of 0.84. The coefficient-of-variation of ELISA and CLIA were 74.5% and 113.1%, respectively. Three value based discordant results were noted; two samples deemed protective by ELISA were reported as non-protective by CLIA. One non-protective titer by ELISA was reported as protective by CLIA. Conclusion Analytical agreement is good between the two immunoassays. However there are some discrepancies in quantitative measurement. This may have been due the variation in the standard calibrators used in each assay. Though CLIA showed more variation in the values, it has the advantage of being automated test with low turn around time. Therefore, both the test methodologies can be reliably used in place of each other for detection of Anti- HBs titer. PMID:28050368

  5. Results of the NIST National Ball Plate Round Robin.

    PubMed

    Caskey, G W; Phillips, S D; Borchardt, B R

    1997-01-01

    This report examines the results of the ball plate round robin administered by NIST. The round robin was part of an effort to assess the current state of industry practices for measurements made using coordinate measuring machines. Measurements of a two-dimensional ball plate (240 mm by 240 mm) on 41 coordinate measuring machines were collected and analyzed. Typically, the deviations of the reported X and Y coordinates from the calibrated values were within ± 5 μm, with some coordinate deviations exceeding 20.0 μm. One of the most significant observations from these data was that over 75 % of the participants failed to correctly estimate their measurement error on one or more of the ball plate spheres.

  6. Nonlinear refractive index measurements and self-action effects in Roselle-Hibiscus Sabdariffa solutions

    NASA Astrophysics Data System (ADS)

    Henari, F. Z.; Al-Saie, A.

    2006-12-01

    We report the observation of self-action phenomena, such as self-focusing, self-defocusing, self-phase modulation and beam fanning in Roselle-Hibiscus Sabdariffa solutions. This material is found to be a new type of natural nonlinear media, and the nonlinear reflective index coefficient has been determined using a Z-scan technique and by measuring the critical power for the self-trapping effect. Z-scan measurements show that this material has a large negative nonlinear refractive index, n 2 = 1 × 10-4 esu. A comparison between the experimental n 2 values and the calculated thermal value for n 2 suggests that the major contribution to nonlinear response is of thermal origin.

  7. Microwave measurements of the absolute values of absorption by water vapour in the atmosphere.

    PubMed

    Hogg, D C; Guiraud, F O

    1979-05-31

    MEASUREMENT of the absolute value of absorption by water vapour at microwave frequencies is difficult because the effect is so small. Far in the wings of the absorption lines, in the so-called 'windows' of the spectrum, it is especially difficult to achieve high accuracy in the free atmosphere. But it is in these windows that the behaviour of the absorption is important from both applied and scientific points of view. Satellite communications, remote sensing of the atmosphere, and radioastronomy, are all influenced by this behaviour. Measurements on an Earth-space path are reported here; the results indicate a nonlinear relationship between absorption and water-vapour content.

  8. Combination of BLOCH oscillations with a Ramsey-Bordé interferometer: new determination of the fine structure constant.

    PubMed

    Cadoret, Malo; de Mirandes, Estefania; Cladé, Pierre; Guellati-Khélifa, Saïda; Schwob, Catherine; Nez, François; Julien, Lucile; Biraben, François

    2008-12-05

    We report a new experimental scheme which combines atom interferometry with Bloch oscillations to provide a new measurement of the ratio h/mRb. By using Bloch oscillations, we impart to the atoms up to 1600 recoil momenta and thus we improve the accuracy on the recoil velocity measurement. The deduced value of h/mRb leads to a new determination of the fine structure constant alpha(-1) =137.03599945 (62) with a relative uncertainty of 4.6 x 10(-9). The comparison of this result with the value deduced from the measurement of the electron anomaly provides the most stringent test of QED.

  9. Intensity-Value Corrections for Integrating Sphere Measurements of Solid Samples Measured Behind Glass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Timothy J.; Bernacki, Bruce E.; Redding, Rebecca L.

    2014-11-01

    Accurate and calibrated directional-hemispherical reflectance spectra of solids are important for both in situ and remote sensing. Many solids are in the form of powders or granules and to measure their diffuse reflectance spectra in the laboratory, it is often necessary to place the samples behind a transparent medium such as glass for the ultraviolet (UV), visible, or near-infrared spectral regions. Using both experimental methods and a simple optical model, we demonstrate that glass (fused quartz in our case) leads to artifacts in the reflectance values. We report our observations that the measured reflectance values, for both hemispherical and diffusemore » reflectance, are distorted by the additional reflections arising at the air–quartz and sample–quartz interfaces. The values are dependent on the sample reflectance and are offset in intensity in the hemispherical case, leading to measured values up to ~6% too high for a 2% reflectance surface, ~3.8% too high for 10% reflecting surfaces, approximately correct for 40–60% diffuse-reflecting surfaces, and ~1.5% too low for 99% reflecting Spectralon® surfaces. For the case of diffuse-only reflectance, the measured values are uniformly too low due to the polished glass, with differences of nearly 6% for a 99% reflecting matte surface. The deviations arise from the added reflections from the quartz surfaces, as verified by both theory and experiment, and depend on sphere design. Finally, empirical correction factors were implemented into post-processing software to redress the artifact for hemispherical and diffuse reflectance data across the 300–2300 nm range.« less

  10. Large plasmaspheric electric fields at L approximately 2 measured by the S3-3 satellite during strong geomagnetic activity

    NASA Technical Reports Server (NTRS)

    Gonzalez, W. D.; Pinto, O., Jr.; Mendes, O., Jr.; Mozer, F. S.

    1986-01-01

    Large plasmaspheric electric fields at L is approximately 2 measured by the S3-3 satellite during strong geomagnetic activity are reported. Since these measurements have amplitudes comparable to those of the local corotation electric field, during such events the plasmasphere is expected to get strongly altered event at such low L-values. Furthermore, those measurements could contribute to the understanding of the physics of the convection/electric field penetration to the low latitude plasmaphere as well as the disturbed dynamo, during strong geomagnetic activity. For this purpose, critical parameters related to geomagnetic activity are also presented for the reported electric field events.

  11. Transport and Fate of Nitroaromatic and Nitramine Explosives in Soils from Open Burning/Open Detonation Operations: Milan Army Ammunition Plant (MAAP)

    DTIC Science & Technology

    1993-12-01

    constitute an official endorsement of any commercial products. This report may not by cited for purposes of advertisement . This report has been approved for...DNT had a lower criterion of detection value than 2,6-DNT (ə.8 vs . ɛ.5 mg L-1 ); however, the 2,6-DNT values are also distributed about this same line...2,6 Units of Measure. UGC Method Number: Laboratory: MA Compound: 2,6 Analysis Date 01/23/91 Matrix: WA ANALYSIS OF RESIDUAL VARIATIONS --- Model with

  12. Disagreement in Parental Reports of Father Involvement

    PubMed Central

    Charles, Pajarita; Spielfogel, Jill; Gorman-Smith, Deborah; Schoeny, Michael; Henry, David; Tolan, Patrick

    2016-01-01

    Despite agreement on the value of father involvement in children’s lives, research has been limited due to the exclusion of fathers in studies, questionable validity of mothers’ reports on father involvement, and simple measures of fathering behavior. Our study extends previous research by comparing reports of father involvement using robust, multidimensional father involvement measures. Data from 113 fathers and 126 mothers reporting on 221 children were used to assess father involvement. Results indicate that fathers reported significantly higher levels of involvement than mothers reported. Findings from hierarchical linear models suggest that race/ethnicity and mothers’ reports of positive relationship quality were associated with smaller discrepancies in reports of father involvement, whereas nonmarried partnerships, older children, father residence, and biological status predicted larger discrepancies. Our study demonstrates the importance of obtaining father involvement reports directly from fathers and why father involvement should be assessed as a multidimensional construct to examine fathering behavior. PMID:29515272

  13. A Blueprint for Pharmacy Benefit Managers to Increase Value

    PubMed Central

    Shrank, William H.; Porter, Michael E.; Jain, Sachin H.; Choudhry, Niteesh K.

    2009-01-01

    Pharmacy benefit managers (PBMs) have a unique opportunity to promote health and generate value in the healthcare system. Today, PBMs are largely evaluated on their ability to control costs rather than improve health. Pharmacy benefit managers should be evaluated along 3 dimensions in which they can increase value: (1) use of cost-effective medications, (2) timely initiation of appropriate medication therapy, and (3) adherence to that therapy. Value creation requires the development of integrated data systems, stronger partnerships with patients and physicians, and improved measurement and reporting of results. Incentives for PBMs to promote value should drive innovation and improve health outcomes. PMID:19284805

  14. Simultaneous determination of thorium, niobium, lead, and zinc by photon-induced x-ray fluorescence of lateritic material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LaBrecque, J.J.; Adames, D.; Parker, W.C.

    1981-01-01

    A rapid method is presented for the simultaneous determinations of thorium, niobium, lead, and zinc in lateritic material from Cerro Impacto, Estado Bolivar, Venezuela. This technique uses a PDP - 11/05 processor - based photon induced x-ray fluorescence system. The total variations of approximately 5% for concentrations of approximately 1 and 10% for concentrations of approximately 0.1% were obtained with only 500 s of fluorescent time. The values obtained by this method were in agreement with values measured by conventional flame atomic absorption spectroscopy for lead and zinc. The values for thorium measured were in agreement with the reported valuesmore » for the reference materials supplied by NBL.« less

  15. New determination of the fine structure constant and test of the quantum electrodynamics.

    PubMed

    Bouchendira, Rym; Cladé, Pierre; Guellati-Khélifa, Saïda; Nez, François; Biraben, François

    2011-02-25

    We report a new measurement of the ratio h/m(Rb) between the Planck constant and the mass of (87)Rb atom. A new value of the fine structure constant is deduced, α(-1)=137.035999037(91) with a relative uncertainty of 6.6×10(-10). Using this determination, we obtain a theoretical value of the electron anomaly a(e)=0.00115965218113(84), which is in agreement with the experimental measurement of Gabrielse [a(e)=0.00115965218073(28)]. The comparison of these values provides the most stringent test of the QED. Moreover, the precision is large enough to verify for the first time the muonic and hadronic contributions to this anomaly. © 2011 American Physical Society

  16. The utility of clinical measures for the diagnosis of achilles tendon injuries: a systematic review with meta-analysis.

    PubMed

    Reiman, Michael; Burgi, Ciara; Strube, Eileen; Prue, Kevin; Ray, Keaton; Elliott, Amanda; Goode, Adam

    2014-01-01

    To summarize and evaluate the current diagnostic accuracy of clinical measures used to diagnose Achilles tendon injuries. A literature search of MEDLINE, CINAHL, and EMBASE databases was conducted with key words related to diagnostic accuracy and Achilles tendon injuries. Original research articles investigating Achilles tendon injuries against an acceptable reference standard were included. Three studies met the inclusion criteria. Quality assessment was conducted using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. DerSimonian-Laird random-effects models were used to pool sensitivity (SN), specificity (SP), and diagnostic odds ratios with their 95% confidence intervals (CIs). The SN and negative likelihood ratio (-LR) values for Achilles tendon rupture measures ranged from 0.73 (95% CI = 0.65, 0.81) and 0.30 (95% CI = 0.23, 0.40) to 0.96 (95% CI = 0.93, 0.99) and 0.04 (95% CI = 0.02, 0.10), respectively, whereas SP and positive likelihood ratio (+LR) values ranged from 0.85 (95% CI = 0.72, 0.98) and 6.29 (95% CI = 2.33, 19.96) to 0.93 (95% CI = 0.84, 1.00) and 13.71 (95% CI = 3.54, 51.24), respectively, with the highest SN and SP both reported in the calf-squeeze test. The SN and -LR values for Achilles tendinopathy measures ranged from 0.03 (95% CI = 0.00, 0.08) and 0.97 (95% CI = not reported) to 0.89 (95% CI = 0.75, 0.98) and 0.19 (95% CI = not reported), whereas SP and +LR values ranged from 0.58 (95% CI = 0.38, 0.77) and 2.12 (95% CI = not reported) to 1.00 (95% CI = 1.00, 1.00) and infinity, respectively, with the highest SN and SP reported for morning stiffness and palpation for crepitus. Pooled analyses demonstrated similar diagnostic properties in all 3 clinical measures (arc sign, palpation, and Royal London Hospital test), with SN and -LR ranging from 0.42 (95% CI = 0.23, 0.62) and 0.68 (95% CI = 0.50, 0.93), respectively, for the arc sign, to 0.64 (95% CI = 0.44, 0.81) and 0.48 (95% CI = 0.29, 0.80), respectively, for palpation. Pooled SP and +LR ranged from 0.81 (95% CI = 0.65, 0.91) and 3.15 (95% CI = 1.61, 6.18), respectively, for palpation, to 0.88 (95% CI = 0.74, 0.96) SP for the arc sign and 3.84 (95% CI = 1.69, 8.73) +LR for the Royal London Hospital test. Most clinical measures for Achilles tendon injury have greater diagnostic than screening capability.

  17. The Utility of Clinical Measures for the Diagnosis of Achilles Tendon Injuries: A Systematic Review With Meta-Analysis

    PubMed Central

    Reiman, Michael; Burgi, Ciara; Strube, Eileen; Prue, Kevin; Ray, Keaton; Elliott, Amanda; Goode, Adam

    2014-01-01

    Objective: To summarize and evaluate the current diagnostic accuracy of clinical measures used to diagnose Achilles tendon injuries. Data Sources: A literature search of MEDLINE, CINAHL, and EMBASE databases was conducted with key words related to diagnostic accuracy and Achilles tendon injuries. Study Selection: Original research articles investigating Achilles tendon injuries against an acceptable reference standard were included. Data Extraction: Three studies met the inclusion criteria. Quality assessment was conducted using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. DerSimonian-Laird random-effects models were used to pool sensitivity (SN), specificity (SP), and diagnostic odds ratios with their 95% confidence intervals (CIs). Data Synthesis: The SN and negative likelihood ratio (−LR) values for Achilles tendon rupture measures ranged from 0.73 (95% CI = 0.65, 0.81) and 0.30 (95% CI = 0.23, 0.40) to 0.96 (95% CI = 0.93, 0.99) and 0.04 (95% CI = 0.02, 0.10), respectively, whereas SP and positive likelihood ratio (+LR) values ranged from 0.85 (95% CI = 0.72, 0.98) and 6.29 (95% CI = 2.33, 19.96) to 0.93 (95% CI = 0.84, 1.00) and 13.71 (95% CI = 3.54, 51.24), respectively, with the highest SN and SP both reported in the calf-squeeze test. The SN and −LR values for Achilles tendinopathy measures ranged from 0.03 (95% CI = 0.00, 0.08) and 0.97 (95% CI = not reported) to 0.89 (95% CI = 0.75, 0.98) and 0.19 (95% CI = not reported), whereas SP and +LR values ranged from 0.58 (95% CI = 0.38, 0.77) and 2.12 (95% CI = not reported) to 1.00 (95% CI = 1.00, 1.00) and infinity, respectively, with the highest SN and SP reported for morning stiffness and palpation for crepitus. Pooled analyses demonstrated similar diagnostic properties in all 3 clinical measures (arc sign, palpation, and Royal London Hospital test), with SN and −LR ranging from 0.42 (95% CI = 0.23, 0.62) and 0.68 (95% CI = 0.50, 0.93), respectively, for the arc sign, to 0.64 (95% CI = 0.44, 0.81) and 0.48 (95% CI = 0.29, 0.80), respectively, for palpation. Pooled SP and +LR ranged from 0.81 (95% CI = 0.65, 0.91) and 3.15 (95% CI = 1.61, 6.18), respectively, for palpation, to 0.88 (95% CI = 0.74, 0.96) SP for the arc sign and 3.84 (95% CI = 1.69, 8.73) +LR for the Royal London Hospital test. Conclusions: Most clinical measures for Achilles tendon injury have greater diagnostic than screening capability. PMID:25243736

  18. Evaluating the Distorting Effects of Inattentive Responding and Social Desirability on Self-Report Scales in Creativity and the Arts

    ERIC Educational Resources Information Center

    McKibben, William Bradley; Silvia, Paul J.

    2017-01-01

    Inattentiveness and social desirability might be particularly problematic for self-report scales in creativity and arts research. Respondents who are inattentive or who present themselves favorably will score highly on scales that yield positively skewed distributions and that assess socially valued constructs, such as scales measuring creativity…

  19. The Role of Attitudes about Vaccine Safety, Efficacy, and Value in Explaining Parents' Reported Vaccination Behavior

    ERIC Educational Resources Information Center

    LaVail, Katherine Hart; Kennedy, Allison Michelle

    2013-01-01

    Objectives: To explain vaccine confidence as it related to parents' decisions to vaccinate their children with recommended vaccines, and to develop a confidence measure to efficiently and effectively predict parents' self-reported vaccine behaviors. Method: A sample of parents with at least one child younger than 6 years ("n" = 376) was…

  20. Adaptive iterated function systems filter for images highly corrupted with fixed - Value impulse noise

    NASA Astrophysics Data System (ADS)

    Shanmugavadivu, P.; Eliahim Jeevaraj, P. S.

    2014-06-01

    The Adaptive Iterated Functions Systems (AIFS) Filter presented in this paper has an outstanding potential to attenuate the fixed-value impulse noise in images. This filter has two distinct phases namely noise detection and noise correction which uses Measure of Statistics and Iterated Function Systems (IFS) respectively. The performance of AIFS filter is assessed by three metrics namely, Peak Signal-to-Noise Ratio (PSNR), Mean Structural Similarity Index Matrix (MSSIM) and Human Visual Perception (HVP). The quantitative measures PSNR and MSSIM endorse the merit of this filter in terms of degree of noise suppression and details/edge preservation respectively, in comparison with the high performing filters reported in the recent literature. The qualitative measure HVP confirms the noise suppression ability of the devised filter. This computationally simple noise filter broadly finds application wherein the images are highly degraded by fixed-value impulse noise.

  1. High-resolution, VUV (147-201 nm) photoabsorption cross sections for C2H2 at 195 and 295 K

    NASA Technical Reports Server (NTRS)

    Smith, Peter L.; Yoshino, Kouichi; Parkinson, W. H.; Ito, Kenji; Stark, Glenn

    1991-01-01

    Results of measurements of photoabsorption cross sections of acetylene at 195 and 295 K in the wavelength range of 147-201 nm are reported. Short-wavelength data are obtained at 0.002 nm intervals, but no structure was observed on that scale. Emission and absorption lines from contaminant species in xenon and hydrogen discharges are used to determine the correct wavelength scale for the data. The uncertainty in the relative wavelengths is estimated to be about 0.004 nm, whereas the absolute wavelength values are accurate to + or - 0.043 nm. No significant photodestruction of C2H2 was found during the measurements. Cross-section values determined at the beginning portions of the measurements are indistinguishable from the values determined at the ends, thus demonstrating that there was no loss of absorbers.

  2. Partial Roc Reveals Superiority of Mutual Rank of Pearson's Correlation Coefficient as a Coexpression Measure to Elucidate Functional Association of Genes

    NASA Astrophysics Data System (ADS)

    Obayashi, Takeshi; Kinoshita, Kengo

    2013-01-01

    Gene coexpression analysis is a powerful approach to elucidate gene function. We have established and developed this approach using vast amount of publicly available gene expression data measured by microarray techniques. The coexpressed genes are used to estimate gene function of the guide gene or to construct gene coexpression networks. In the case to construct gene networks, researchers should introduce an arbitrary threshold of gene coexpression, because gene coexpression value is continuous value. In the viewpoint to introduce common threshold of gene coexpression, we previously reported rank of Pearson's correlation coefficient (PCC) is more useful than the original PCC value. In this manuscript, we re-assessed the measure of gene coexpression to construct gene coexpression network, and found that mutual rank (MR) of PCC showed better performance than rank of PCC and the original PCC in low false positive rate.

  3. Twin Knudsen Cell Configuration for Activity Measurements by Mass Spectrometry

    NASA Technical Reports Server (NTRS)

    Jacobson, N. S.

    1996-01-01

    A twin Knudsen cell apparatus for alloy activity measurements by mass spectrometry is described. Two Knudsen cells - one containing an alloy and one containing a pure component - are mounted on a single flange and translated into the sampling region via a motorized x-y table. Mixing of the molecular beams from the cells is minimized by a novel system of shutters. Activity measurements were taken on two well-characterized alloys to verify the operation of the system. Silver activity measurements are reported for Ag-Cu alloys and aluminum activity measurements are reported for Fe-Al alloys. The temperature dependence of activity for a 0.474 mol fraction Al-Fe alloy gives a partial molar heat of aluminum. Measurements taken with the twin cell show good agreement with literature values for these alloys.

  4. Reliability, reference values and predictor variables of the ulnar sensory nerve in disease free adults.

    PubMed

    Ruediger, T M; Allison, S C; Moore, J M; Wainner, R S

    2014-09-01

    The purposes of this descriptive and exploratory study were to examine electrophysiological measures of ulnar sensory nerve function in disease free adults to determine reliability, determine reference values computed with appropriate statistical methods, and examine predictive ability of anthropometric variables. Antidromic sensory nerve conduction studies of the ulnar nerve using surface electrodes were performed on 100 volunteers. Reference values were computed from optimally transformed data. Reliability was computed from 30 subjects. Multiple linear regression models were constructed from four predictor variables. Reliability was greater than 0.85 for all paired measures. Responses were elicited in all subjects; reference values for sensory nerve action potential (SNAP) amplitude from above elbow stimulation are 3.3 μV and decrement across-elbow less than 46%. No single predictor variable accounted for more than 15% of the variance in the response. Electrophysiologic measures of the ulnar sensory nerve are reliable. Absent SNAP responses are inconsistent with disease free individuals. Reference values recommended in this report are based on appropriate transformations of non-normally distributed data. No strong statistical model of prediction could be derived from the limited set of predictor variables. Reliability analyses combined with relatively low level of measurement error suggest that ulnar sensory reference values may be used with confidence. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  5. Evaluation of Low-Cost Mitigation Measures Implemented to Improve Air Quality in Nursery and Primary Schools.

    PubMed

    Sá, Juliana P; Branco, Pedro T B S; Alvim-Ferraz, Maria C M; Martins, Fernando G; Sousa, Sofia I V

    2017-05-31

    Indoor air pollution mitigation measures are highly important due to the associated health impacts, especially on children, a risk group that spends significant time indoors. Thus, the main goal of the work here reported was the evaluation of mitigation measures implemented in nursery and primary schools to improve air quality. Continuous measurements of CO₂, CO, NO₂, O₃, CH₂O, total volatile organic compounds (VOC), PM₁, PM 2.5 , PM 10 , Total Suspended Particles (TSP) and radon, as well as temperature and relative humidity were performed in two campaigns, before and after the implementation of low-cost mitigation measures. Evaluation of those mitigation measures was performed through the comparison of the concentrations measured in both campaigns. Exceedances to the values set by the national legislation and World Health Organization (WHO) were found for PM 2.5 , PM 10 , CO₂ and CH₂O during both indoor air quality campaigns. Temperature and relative humidity values were also above the ranges recommended by American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). In general, pollutant concentrations measured after the implementation of low-cost mitigation measures were significantly lower, mainly for CO₂. However, mitigation measures were not always sufficient to decrease the pollutants' concentrations till values considered safe to protect human health.

  6. Looking Good or Being Good? The Role of Social Desirability Tendencies in Student Perceptions of Institutional Mission and Values

    ERIC Educational Resources Information Center

    Ferrari, Joseph R.; Bristow, Maya; Cowman, Shaun E.

    2005-01-01

    Two samples of college students (Sample 1, n = 106 Sample 2, n = 107) completed self-report measures that assessed their perceptions of their university's mission and values along with their tendency to seek social approval. With Sample 1, global social desirability was not predictive of any student perceptions related to institutional mission and…

  7. Coping with Pain in the Motivational Context of Values: Comparison between an Acceptance-Based and a Cognitive Control-Based Protocol

    ERIC Educational Resources Information Center

    Paez-Blarrina, Marisa; Luciano, Carmen; Gutierrez-Martinez, Olga; Valdivia, Sonsoles; Rodriguez-Valverde, Miguel; Ortega, Jose

    2008-01-01

    This study compares the effect of an acceptance-based protocol (ACT) and a cognitive control-based (CONT) protocol on three measures of pain coping: tolerance, self-report, and believability. Specific methodological controls were employed to further isolate the role of the value of participating in a pain task, compared to previous investigations…

  8. Absolute Transition Probabilities of Lines in the Spectra of Astrophysical Atoms, Molecules, and Ions

    NASA Technical Reports Server (NTRS)

    Parkinson, W. H.; Smith, P. L.; Yoshino, K.

    1984-01-01

    Progress in the investigation of absolute transition probabilities (A-values or F values) for ultraviolet lines is reported. A radio frequency ion trap was used for measurement of transition probabilities for intersystem lines seen in astronomical spectra. The intersystem line at 2670 A in Al II, which is seen in pre-main sequence stars and symbiotic stars, was studied.

  9. Maximum human objectively measured pharmacologically stimulated accommodative amplitude.

    PubMed

    Grzybowski, Andrzej; Schachar, Ronald A; Gaca-Wysocka, Magdalena; Schachar, Ira H; Pierscionek, Barbara K

    2018-01-01

    To measure the maximum, objectively measured, accommodative amplitude, produced by pharmacologic stimulation. Thirty-seven healthy subjects were enrolled, with a mean age of 20.2±1.1 years, corrected visual acuity of 20/20, and mean spherical equivalent refraction (SER) =-0.83±1.60 diopters. For each subject, the right pupil was dilated with phenylephrine 10%. After 30 minutes, the pupil was measured, the left eye was patched, and the right eye was autorefracted. Pilocarpine 4% was then instilled in the right eye, followed by phenylephrine. At 45 minutes after the pilocarpine, autorefraction and pupil size were again measured. Mean pupil size pre- and postpilocarpine was 8.0±0.8 mm and 4.4±1.9 mm, respectively. Pre- and postpilocarpine, the mean SER was -0.83±1.60 and -10.55±4.26 diopters, respectively. The mean pilocarpine-induced accommodative amplitude was 9.73±3.64 diopters. Five subjects had accommodative amplitudes ≥14.00 diopters. Accommodative amplitude was not significantly related to baseline SER ( p -value =0.24), pre- or postpilocarpine pupil size ( p -values =0.13 and 0.74), or change in pupil size ( p -value =0.37). Iris color did not statistically significantly affect accommodative amplitude ( p -value =0.83). Following topically applied pilocarpine, the induced objectively measured accommodation in the young eye is greater than or equal to the reported subjectively measured voluntary maximum accommodative amplitude.

  10. Reference Values for the Pediatric Quality of Life Inventory and the Multidimensional Fatigue Scale in Adolescent Athletes by Sport and Sex.

    PubMed

    Snyder Valier, Alison R; Welch Bacon, Cailee E; Bay, R Curtis; Molzen, Eileen; Lam, Kenneth C; Valovich McLeod, Tamara C

    2017-10-01

    Effective use of patient-rated outcome measures to facilitate optimal patient care requires an understanding of the reference values of these measures within the population of interest. Little is known about reference values for commonly used patient-rated outcome measures in adolescent athletes. To determine reference values for the Pediatric Quality of Life Inventory (PedsQL) and the Multidimensional Fatigue Scale (MFS) in adolescent athletes by sport and sex. Cross-sectional study; Level of evidence, 3. A convenience sample of interscholastic adolescent athletes from 9 sports was used. Participants completed the PedsQL and MFS during one testing session at the start of their sport season. Data were stratified by sport and sex. Dependent variables included the total PedsQL score and the 5 PedsQL subscale scores: physical functioning, psychosocial functioning, emotional functioning, social functioning, and school functioning. Dependent variables for the MFS included 3 subscale scores: general functioning, sleep functioning, and cognitive functioning. Summary statistics were reported for total and subscale scores by sport and sex. Among 3574 males and 1329 female adolescent athletes, the PedsQL scores (100 possible points) generally indicated high levels of health regardless of sport played. Mean PedsQL total and subscales scores ranged from 82.6 to 95.7 for males and 83.9 to 95.2 for females. Mean MFS subscale scores (100 possible points) ranged from 74.2 to 90.9 for males and 72.8 to 87.4 for females. Healthy male and female adolescent athletes reported relatively high levels of health on the PedsQL subscales and total scores regardless of sport; no mean scores were lower than 82.6 points for males or 83.9 points for females. On the MFS, males and females tended to report low effect of general and cognitive fatigue regardless of sport; mean scores were higher than 83.5 points for males and 83.8 points for females. Clinically, athletes who score below the reference values for their sport have poorer health status than average adolescent athletes participating in that sport. Scores below reference values may warrant consideration of early intervention or treatment.

  11. The value of health information technology: filling the knowledge gap.

    PubMed

    Rudin, Robert S; Jones, Spencer S; Shekelle, Paul; Hillestad, Richard J; Keeler, Emmett B

    2014-11-01

    Despite rapid growth in the rate of adoption of health information technology (HIT), and in the volume of evaluation studies, the existing knowledge base for the value of HIT is not advancing at a similar rate. Most evaluation articles are limited in that they use incomplete measures of value and fail to report the important contextual and implementation characteristics that would allow for an adequate understanding of how the study results were achieved. To address these deficiencies, we present a conceptual framework for measuring HIT value and we propose a checklist of characteristics that should be considered in HIT evaluation studies. The framework consists of 3 key principles: 1) value includes both costs and benefits; 2) value accrues over time; and 3) value depends on which stakeholder's perspective is used. Through examples, we show how these principles can be used to guide and improve HIT evaluation studies. The checklist includes a list of contextual and implementation characteristics that are important for interpretation of results. These improvements will make future studies more useful for policy makers and more relevant to the current needs of the healthcare system.

  12. Quality of Liver and Kidney Function Tests among Public Medical Laboratories in Western Region of Amhara National Regional State of Ethiopia.

    PubMed

    Teka, Abaynesh; Kibatu, Girma

    2012-03-01

    Medical laboratories play essential roles in measurements of substances in body fluids for the purpose of diagnosis, treatment, prevention, and for greater understanding of the disease process. Thus, data generated from have to be reliable for which strict quality control, management and assurance are maintained. The aim of this study is to assess the accuracy and precision of clinical chemistry laboratories in western region of Amhara national regional state of Ethiopia in testing liver and kidney functions. Eight laboratories in hospitals and a Regional Health Research Laboratory Center participated in this study from February to March, 2011. Each participant was requested to measure six specimens for six chemistry tests from two control samples. Three hundred twenty four test results to be reported from all participant laboratories, if all measurements can be made, were designed to be collected and statistically evaluated. None of the study subject laboratories could deliver all the six tests for estimation of both liver and renal functions simultaneously during the study period. Only 213 values from the expected 324 values were reported and about 65 % of the 213 values reported fell outside of the allowable limits of errors for the chemistry tests of the control specimen used. This study finding showed that there were lack of accuracy and precision in chemistry measurements. A regular survey on medical laboratories should be conducted questioning the accuracy and precision of their analyses in order to sustain improvements in the quality of services provided by participating laboratories for the benefit of patients. Laboratory Quality Management Systems appreciate the need for regular quality control and quality assessment schemes in medical laboratories.

  13. Validation of self-reported anthropometrics in the Adventist Health Study 2

    PubMed Central

    2011-01-01

    Background Relying on self-reported anthropometric data is often the only feasible way of studying large populations. In this context, there are no studies assessing the validity of anthropometrics in a mostly vegetarian population. The objective of this study was to evaluate the validity of self-reported anthropometrics in the Adventist Health Study 2 (AHS-2). Methods We selected a representative sample of 911 participants of AHS-2, a cohort of over 96,000 adult Adventists in the USA and Canada. Then we compared their measured weight and height with those self-reported at baseline. We calculated the validity of the anthropometrics as continuous variables, and as categorical variables for the definition of obesity. Results On average, participants underestimated their weight by 0.20 kg, and overestimated their height by 1.57 cm resulting in underestimation of body mass index (BMI) by 0.61 kg/m2. The agreement between self-reported and measured BMI (as a continuous variable), as estimated by intraclass correlation coefficient, was 0.97. The sensitivity of self-reported BMI to detect obesity was 0.81, the specificity 0.97, the predictive positive value 0.93, the predictive negative value 0.92, and the Kappa index 0.81. The percentage of absolute agreement for each category of BMI (normoweight, overweight, and obese) was 83.4%. After multivariate analyses, predictors of differences between self-reported and measured BMI were obesity, soy consumption and the type of dietary pattern. Conclusions Self-reported anthropometric data showed high validity in a representative subsample of the AHS-2 being valid enough to be used in epidemiological studies, although it can lead to some underestimation of obesity. PMID:21466678

  14. Validation of self-reported anthropometrics in the Adventist Health Study 2.

    PubMed

    Bes-Rastrollo, Maira; Sabaté, Joan; Jaceldo-Siegl, Karen; Fraser, Gary E

    2011-04-05

    Relying on self-reported anthropometric data is often the only feasible way of studying large populations. In this context, there are no studies assessing the validity of anthropometrics in a mostly vegetarian population. The objective of this study was to evaluate the validity of self-reported anthropometrics in the Adventist Health Study 2 (AHS-2). We selected a representative sample of 911 participants of AHS-2, a cohort of over 96,000 adult Adventists in the USA and Canada. Then we compared their measured weight and height with those self-reported at baseline. We calculated the validity of the anthropometrics as continuous variables, and as categorical variables for the definition of obesity. On average, participants underestimated their weight by 0.20 kg, and overestimated their height by 1.57 cm resulting in underestimation of body mass index (BMI) by 0.61 kg/m(2). The agreement between self-reported and measured BMI (as a continuous variable), as estimated by intraclass correlation coefficient, was 0.97. The sensitivity of self-reported BMI to detect obesity was 0.81, the specificity 0.97, the predictive positive value 0.93, the predictive negative value 0.92, and the Kappa index 0.81. The percentage of absolute agreement for each category of BMI (normoweight, overweight, and obese) was 83.4%. After multivariate analyses, predictors of differences between self-reported and measured BMI were obesity, soy consumption and the type of dietary pattern. Self-reported anthropometric data showed high validity in a representative subsample of the AHS-2 being valid enough to be used in epidemiological studies, although it can lead to some underestimation of obesity.

  15. Junction Potentials Bias Measurements of Ion Exchange Membrane Permselectivity.

    PubMed

    Kingsbury, Ryan S; Flotron, Sophie; Zhu, Shan; Call, Douglas F; Coronell, Orlando

    2018-04-17

    Ion exchange membranes (IEMs) are versatile materials relevant to a variety of water and waste treatment, energy production, and industrial separation processes. The defining characteristic of IEMs is their ability to selectively allow positive or negative ions to permeate, which is referred to as permselectivity. Measured values of permselectivity that equal unity (corresponding to a perfectly selective membrane) or exceed unity (theoretically impossible) have been reported for cation exchange membranes (CEMs). Such nonphysical results call into question our ability to correctly measure this crucial membrane property. Because weighing errors, temperature, and measurement uncertainty have been shown to not explain these anomalous permselectivity results, we hypothesized that a possible explanation are junction potentials that occur at the tips of reference electrodes. In this work, we tested this hypothesis by comparing permselectivity values obtained from bare Ag/AgCl wire electrodes (which have no junction) to values obtained from single-junction reference electrodes containing two different electrolytes. We show that permselectivity values obtained using reference electrodes with junctions were greater than unity for CEMs. In contrast, electrodes without junctions always produced permselectivities lower than unity. Electrodes with junctions also resulted in artificially low permselectivity values for AEMs compared to electrodes without junctions. Thus, we conclude that junctions in reference electrodes introduce two biases into results in the IEM literature: (i) permselectivity values larger than unity for CEMs and (ii) lower permselectivity values for AEMs compared to those for CEMs. These biases can be avoided by using electrodes without a junction.

  16. Value in cardiovascular care.

    PubMed

    Bradley, Steven M; Strauss, Craig E; Ho, P Michael

    2017-08-01

    Healthcare value, defined as health outcomes achieved relative to the costs of care, has been proposed as a unifying approach to measure improvements in the quality and affordability of healthcare. Although value is of increasing interest to payers, many providers remain unfamiliar with how value differs from other approaches to the comparison of cost and outcomes (ie, cost-effectiveness analysis). While cost-effectiveness studies can be used by policy makers and payers to inform decisions about coverage and reimbursement for new therapies, the assessment of healthcare can guide improvements in the delivery of healthcare to achieve better outcomes at lower cost. Comparison on value allows for the identification of healthcare delivery organisations or care delivery settings where patient outcomes have been optimised at a lower cost. Gaps remain in the measurement of healthcare value, particularly as it relates to patient-reported health status (symptoms, functional status and health-related quality of life). The use of technology platforms that capture health status measures with minimal disruption to clinical workflow (ie, web portals, automated telephonic systems and tablets to facilitate capture outside of in-person clinical interaction) is facilitating use of health status measures to improve clinical care and optimise patient outcomes. Furthermore, the use of a value framework has catalysed quality improvement efforts and research to seek better patient outcomes at lower cost. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Coefficient of Thermal Expansion of Pressed PETN Pellets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thompson, Darla Graff; DeLuca, Racci

    2015-03-11

    The PETN single crystal coefficient of thermal expansion (CTE) values were measured and reported by Cady in 1972 [1] over the temperature range of -160 to 100°C. Measurements were made in the (001) and (100) crystallographic directions, see Figure 1 (a replicate of Figure 1 from the Cady paper). Cady used his single-crystal data to calculate the linear CTE for a randomly-oriented multi-crystal pressing of PETN, and his values ranged from 76.5 με/°C (at 20°C) to 89.9 5 με/°C (at 90°C).

  18. Validity of smoke alarm self-report measures and reasons for over-reporting.

    PubMed

    Stepnitz, Rebecca; Shields, Wendy; McDonald, Eileen; Gielen, Andrea

    2012-10-01

    Many residential fire deaths occur in homes with no or non-functioning smoke alarms (SAs). Self-reported SA coverage is high, but studies have found varying validity for self-report measures. The authors aim to: (1) determine over-reporting of coverage, (2) describe socio-demographic correlates of over-reporting and (3) report reasons for over-reporting. The authors surveyed 603 households in a large, urban area about fire safety behaviours and then tested all SAs in the home. 23 participants who over-reported their SA coverage were telephoned and asked about why they had misreported. Full coverage was reported in 70% of households but observed in only 41%, with a low positive predictive value (54.2%) for the self-report measure. Most over-reporters assumed alarms were working because they were mounted or did not think a working alarm in a basement or attic was needed to be fully protected. If alarms cannot be tested, researchers or those counselling residents on fire safety should carefully probe self-reported coverage. Our findings support efforts to equip more homes with hard-wired or 10 year lithium battery alarms to reduce the need for user maintenance.

  19. Experimental radiative lifetimes, branching fractions, and oscillator strengths of some levels in Co I

    NASA Astrophysics Data System (ADS)

    Wang, Xinghao; Yu, Qi; Li, Qiu; Gao, Yang; Dai, Zhenwen

    2018-04-01

    The radiative lifetime measurements by the time-resolved laser-induced fluorescence technique are reported for 24 levels of Co I with the energy range of 283 45.86-55 922.3 cm-1, amongst which the lifetimes of 20 levels are reported for the first time. The branching fraction measurements by the emission spectrum of a hollow cathode lamp were performed for 11 levels of them together with other two levels reported in the literature, and branching fractions of 39 transitions were obtained. By combining them with lifetime values, the transition probabilities and absolute oscillator strengths of these lines were determined.

  20. Main-channel slopes of selected streams in Iowa for estimation of flood-frequency discharges

    USGS Publications Warehouse

    Eash, David A.

    2003-01-01

    This report describes a statewide study conducted to develop main-channel slope (MCS) curves for 138 selected streams in Iowa with drainage areas greater than 100 square miles. MCS values determined from the curves can be used in regression equations for estimating floodfrequency discharges. Multivariable regression equations previously developed for two of the three hydrologic regions defined for Iowa require the measurement of MCS. Main-channel slope is a difficult measurement to obtain for large streams using 1:24,000-scale topographic maps. The curves developed in this report provide a simplified method for determining MCS values for sites located along large streams in Iowa within hydrologic Regions 2 and 3. The curves were developed using MCS values quantified for 2,058 selected sites along 138 selected streams in Iowa. A geographic information system (GIS) technique and 1:24,000-scale topographic data were used to quantify MCS values for the stream sites. The sites were selected at about 5-mile intervals along the streams. River miles were quantified for each stream site using a GIS program. Data points for river-mile and MCS values were plotted and a best-fit curve was developed for each stream. An adjustment was applied to all 138 curves to compensate for differences in MCS values between manual measurements and GIS quantifications. The multivariable equations for Regions 2 and 3 were developed using manual measurements of MCS. A comparison of manual measurements and GIS quantifications of MCS indicates that manual measurements typically produce greater values of MCS compared to GIS quantifications. Median differences between manual measurements and GIS quantifications of MCS are 14.8 and 17.7 percent for Regions 2 and 3, respectively. Comparisons of percentage differences between flood-frequency discharges calculated using MCS values of manual measurements and GIS quantifications indicate that use of GIS values of MCS for Region 3 substantially underestimate flood discharges. Mean and median percentage differences for 2- to 500-year recurrence- interval flood discharges ranged from 5.0 to 5.3 and 4.3 to 4.5 percent, respectively, for Region 2 and ranged from 18.3 to 27.1 and 12.3 to 17.3 percent for Region 3. The MCS curves developed from GIS quantifications were adjusted by 14.8 percent for streams located in Region 2 and by 17.7 percent for streams located in Region 3. Comparisons of percentage differences between flood discharges calculated using MCS values of manual measurements and adjusted-GIS quantifications for Regions 2 and 3 indicate that the flood-discharge estimates are comparable. For Region 2, mean percentage differences for 2- to 500-year recurrence- interval flood discharges ranged between 0.6 and 0.8 percent and median differences were 0.0 percent. For Region 3, mean and median differences ranged between 5.4 to 8.4 and 0.0 to 0.3 percent, respectively. A list of selected stream sites presented with each curve provides information about the sites including river miles, drainage areas, the location of U.S. Geological Survey streamflowgaging stations, and the location of streams crossing hydrologic region boundaries or the Des Moines Lobe landform region boundary. Two examples are presented for determining river-mile and MCS values, and two techniques are presented for computing flood-frequency discharges.

  1. Using the Patient Reported Outcomes Measurement Information System to Evaluate Psychosocial Functioning among Children with Craniofacial Anomalies.

    PubMed

    Shapiro, Danielle N; Waljee, Jennifer; Ranganathan, Kavitha; Buchman, Steven; Warschausky, Seth

    2015-06-01

    Children with craniofacial anomalies are at risk for social exclusion, bullying, and psychological symptoms, all of which are associated with poor developmental and health outcomes. The National Institutes of Health-developed Patient Reported Outcomes Measurement Information System instruments may be useful tools for monitoring psychosocial functioning in clinical settings and for integrating patient and parent perspectives. The current study included 74 children (50 percent male) with craniofacial anomalies recruited through a multidisciplinary clinic. The authors obtained child self-report and parent-proxy ratings of depression, anxiety, and peer relationship quality using National Institutes of Health Patient Reported Outcomes Measurement Information System instruments. The authors compared sample means to Patient Reported Outcomes Measurement Information System instruments norms and analyzed the reliability of parents' and children's reporting of psychosocial variables. All reliability statistics were satisfactory (α values ranging from 0.74 to 0.96) and sample standard deviations were similar to those obtained in a general population, suggesting that Patient Reported Outcomes Measurement Information System instruments are reliable among children with craniofacial anomalies. In general, children and parents did not report unusual levels of psychological distress; however, they did report poorer peer relationship quality relative to normed data, a trend that was particularly pronounced among boys. National Institutes of Health Patient Reported Outcomes Measurement Information System instruments are efficient and accurate tools for monitoring psychosocial adjustment among children with craniofacial anomalies. It may be especially important to monitor social functioning, particularly among boys.

  2. Quantitative and simultaneous non-invasive measurement of skin hydration and sebum levels

    PubMed Central

    Ezerskaia, Anna; Pereira, S. F.; Urbach, H. Paul; Verhagen, Rieko; Varghese, Babu

    2016-01-01

    We report a method on quantitative and simultaneous non-contact in-vivo hydration and sebum measurements of the skin using an infrared optical spectroscopic set-up. The method utilizes differential detection with three wavelengths 1720, 1750, and 1770 nm, corresponding to the lipid vibrational bands that lay “in between” the prominent water absorption bands. We have used an emulsifier containing hydro- and lipophilic components to mix water and sebum in various volume fractions which was applied to the skin to mimic different oily-dry skin conditions. We also measured the skin sebum and hydration values on the forehead under natural conditions and its variations to external stimuli. Good agreement was found between our experimental results and reference values measured using conventional biophysical methods such as Corneometer and Sebumeter. PMID:27375946

  3. Accuracy of the Medication Adherence Report Scale (MARS-5) as a quantitative measure of adherence to inhalation medication in patients with COPD.

    PubMed

    Tommelein, Eline; Mehuys, Els; Van Tongelen, Inge; Brusselle, Guy; Boussery, Koen

    2014-05-01

    Self-report is considered most suitable to measure medication adherence in routine clinical practice. However, accuracy of self-report as a quantitative measure of adherence is not well documented. To assess the accuracy of a self-report measure of adherence (Medication Adherence Report Scale [MARS-5]) for identifying nonadherent users of inhalation medication among patients with chronic obstructive pulmonary disease (COPD), compared with medication refill adherence (MRA) as reference. We used baseline data from the Pharmaceutical Care for Patients with COPD (PHARMACOP)-trial (n = 734). Patients with incomplete MARS-5 and/or incomplete pharmacy refill records were excluded (n = 121). Internal consistency of MARS-5 (Crohnbach α) and Spearman rank correlation (ρ) with MRA were calculated. Different thresholds for nonadherence were used to calculate sensitivity, specificity, and positive predictive value (PPV), compared with dichotomized MRA (MRA ≥80% = adherent). A receiver operating characteristic (ROC) curve was plotted to determine the goodness of test. 613 patients were included in the analysis. The mean adherence score by MARS-5 (range = 5-25) was 23.5 (SD = 2.6); mean adherence by MRA was 83.4% (SD = 23.8%). Internal consistency of MARS-5 was high (α = 0.77). Continuous MARS-5 scores correlated poorly with continuous MRA scores (ρ = 0.10; P = 0.011). When lowering the nonadherence threshold stepwise from 25 to 20, MARS-5 did not reach sufficient sensitivity (53% to 13%), specificity (57% to 94%), and PPV (42% to 57%) to detect nonadherers compared with dichotomized MRA. ROC curve plotting resulted in an area under the curve value of 0.56 (95% CI = 0.521-0.616; P = 0.005). Self-reported adherence measured by MARS-5 is inaccurate in identifying nonadherence to inhalation medication in patients with COPD.

  4. Direct Measurements of the Penetration Depth in a Superconducting Film using Magnetic Force Microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    E Nazaretski; J Thibodaux; I Vekhter

    2011-12-31

    We report the local measurements of the magnetic penetration depth in a superconducting Nb film using magnetic force microscopy (MFM). We developed a method for quantitative extraction of the penetration depth from single-parameter simultaneous fits to the lateral and height profiles of the MFM signal, and demonstrate that the obtained value is in excellent agreement with that obtained from the bulk magnetization measurements.

  5. Beyond the Shadow of a Trait: Understanding Discounting through Item-Level Analysis of Personality Scales

    ERIC Educational Resources Information Center

    Charlton, Shawn R.; Gossett, Bradley D.; Charlton, Veda A.

    2011-01-01

    Temporal discounting, the loss in perceived value associated with delayed outcomes, correlates with a number of personality measures, suggesting that an item-level analysis of trait measures might provide a more detailed understanding of discounting. The current report details two studies that investigate the utility of such an item-level…

  6. Quantum nondemolition readout using a Josephson bifurcation amplifier

    NASA Astrophysics Data System (ADS)

    Boulant, N.; Ithier, G.; Meeson, P.; Nguyen, F.; Vion, D.; Esteve, D.; Siddiqi, I.; Vijay, R.; Rigetti, C.; Pierre, F.; Devoret, M.

    2007-07-01

    We report an experiment on the determination of the quantum nondemolition (QND) nature of a readout scheme of a quantum electrical circuit. The circuit is a superconducting quantum bit measured by microwave reflectometry using a Josephson bifurcation amplifier. We perform a series of two subsequent measurements, record their values and correlation, and quantify the QND character of this readout.

  7. Solubility of HCL in sulfuric acid at stratospheric temperatures

    NASA Technical Reports Server (NTRS)

    Williams, Leah R.; Golden, David M.

    1993-01-01

    The solubility of HCl in sulfuric acid was measured using a Knudsen cell technique. Effective Henry's law constants are reported for sulfuric acid concentrations between 50 and 60 weight percent and for temperatures between 220 and 230 K. The measured values indicate that very little HCl will be dissolved in the stratospheric sulfate aerosol particles.

  8. Electron-acoustic phonon coupling in single crystal CH3NH3PbI3 perovskites revealed by coherent acoustic phonons

    NASA Astrophysics Data System (ADS)

    Mante, Pierre-Adrien; Stoumpos, Constantinos C.; Kanatzidis, Mercouri G.; Yartsev, Arkady

    2017-02-01

    Despite the great amount of attention CH3NH3PbI3 has received for its solar cell application, intrinsic properties of this material are still largely unknown. Mobility of charges is a quintessential property in this aspect; however, there is still no clear understanding of electron transport, as reported values span over three orders of magnitude. Here we develop a method to measure the electron and hole deformation potentials using coherent acoustic phonons generated by femtosecond laser pulses. We apply this method to characterize a CH3NH3PbI3 single crystal. We measure the acoustic phonon properties and characterize electron-acoustic phonon scattering. Then, using the deformation potential theory, we calculate the carrier intrinsic mobility and compare it to the reported experimental and theoretical values. Our results reveal high electron and hole mobilities of 2,800 and 9,400 cm2 V-1 s-1, respectively. Comparison with literature values of mobility demonstrates the potential role played by polarons in charge transport in CH3NH3PbI3.

  9. Evaluation of the acoustoelectric effect in the thickness direction of c-plane ZnO single crystals by Brillouin scattering

    NASA Astrophysics Data System (ADS)

    Tomita, Shota; Yanagitani, Takahiko; Takayanagi, Shinji; Ichihashi, Hayato; Shibagaki, Yoshiaki; Hayashi, Hiromichi; Matsukawa, Mami

    2017-06-01

    Longitudinal wave velocity dispersion in ZnO single crystals, owing to the acoustoelectric effect, has been investigated by Brillouin scattering. The resistivity dependence of the longitudinal wave velocity in a c-plane ZnO single crystal was theoretically estimated and experimentally investigated. Velocity dispersion owing to the acoustoelectric effect was observed in the range 0.007-10 Ωm. The observed velocity dispersion shows a similar tendency to the theoretical estimation and gives the piezoelectric stiffened and unstiffened wave velocities. However, the measured dispersion curve shows a characteristic shift from the theoretical curve. One possible reason is the carrier mobility in the sample, which could be lower than the reported value. The measurement data gave the piezoelectric stiffened and unstiffened longitudinal wave velocities, from which the electromechanical coupling coefficient k33 was determined. The value of k33 is in good agreement with reported values. This method is promising for noncontact evaluation of electromechanical coupling. In particular, it could be for evaluation of the unknown piezoelectricity in the thickness direction of semiconductive materials and film resonators.

  10. Surface measurements of upper tropospheric water vapor isotopic composition on the Chajnantor Plateau, Chile

    NASA Astrophysics Data System (ADS)

    Galewsky, Joseph; Rella, Christopher; Sharp, Zachary; Samuels, Kimberly; Ward, Dylan

    2011-09-01

    Simultaneous, real-time measurements of atmospheric water vapor mixing ratio and isotopic composition (δD and δ18O) were obtained using cavity ringdown spectroscopy on the arid Chajnantor Plateau in the subtropical Chilean Andes (elevation 5080 m or 550 hPa; latitude 23°S) during July and August 2010. The measurements show surface water vapor mixing ratio as low as 215 ppmv, δD values as low as -540‰, and δ18O values as low as -68‰, which are the lowest atmospheric water vapor δ values reported from Earth's surface. The results are consistent with previous measurements from the base of the tropical tropopause layer (TTL) and suggest large-scale subsidence of air masses from the upper troposphere to the Earth's surface. The range of measurements is consistent with condensation under conditions of ice supersaturation and mixing with moister air from the lower troposphere that has been processed through shallow convection. Diagnostics using reanalysis data show that the extreme aridity of the Chajnantor Plateau is controlled by condensation in the upper tropical troposphere.

  11. When do drilling alliances add value? The alliance value model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brett, J.F.; Craig, V.B.; Wadsworth, D.B.

    1996-12-31

    A recent GRI report details three previously unstudied aspects of alliances: specific measurable factors that improve alliance success, how a successful alliance should be structured, and when an alliance makes economic sense. The most innovative tool to emerge from the report, the Alliance Value Model, addresses the third aspect. The theory behind the Alliance Value Model is that the long-term viability of any drilling relationship hinges on its ability to create real value and achieve stability. Based upon the report`s findings, the most effective way to form such an alliance is through a detailed description and integration of the technicalmore » processes involved. This new type of process-driven alliance is characterized by a value chain which links together a common set of technical processes, mutually defined bottomline goals, and shared benefits. Building a process-driven alliance requires time and people and therefore has an associated cost. The real value generated by an alliance must exceed this start-up cost. The Alliance Value Model computes the net present value (NPV) of the cash flows for four different operating arrangements: (1) Business As Usual (conventional competitive bidding process), (2) Process-Driven Alliance (linking technical processes to accelerate production and reduce expenses), (3) Incentivized Process-Driven Alliance (linked technical processes with performance incentives to promote stability), and (4) No Drill Case (primarily used to gauge the market value of services). These arrangements test different degrees of process integration between an operator and its suppliers. They can also help determine if the alliance can add enough value to exceed startup costs and if the relationship will be stable. Each partner can test the impact of the relational structure on its own profitability. When an alliance is warranted, all participants can benefit from real value generated in a stable relationship.« less

  12. ARM Climate Research Facility Quarterly Value-Added Product Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sivaraman, C.

    The purpose of this report is to provide a concise status update for Value-Added Products (VAPs) implemented by the Atmospheric Radiation Measurement (ARM) Climate Research Facility. The report is divided into the following sections: (1) new VAPs for which development has begun; (2) progress on existing VAPs; (3) future VAPs that have been recently approved; (4) other work that leads to a VAP; (5) top requested VAPs from the ARM Data Archive; and (6) a summary of VAP and data releases to production and evaluation. New information is highlighted in blue text. New information about processed data by the developermore » is highlighted in red text. The upcoming milestones and dates are highlighted in green.« less

  13. Quantifying Preferences for the Natural World Using Monetary and Nonmonetary Assessments of Value

    PubMed Central

    DALLIMER, MARTIN; TINCH, DUGALD; HANLEY, NICK; IRVINE, KATHERINE N; ROUQUETTE, JAMES R; WARREN, PHILIP H; MALTBY, LORRAINE; GASTON, KEVIN J; ARMSWORTH, PAUL R

    2014-01-01

    Given that funds for biodiversity conservation are limited, there is a need to understand people’s preferences for its different components. To date, such preferences have largely been measured in monetary terms. However, how people value biodiversity may differ from economic theory, and there is little consensus over whether monetary metrics are always appropriate or the degree to which other methods offer alternative and complementary perspectives on value. We used a choice experiment to compare monetary amounts recreational visitors to urban green spaces were willing to pay for biodiversity enhancement (increases in species richness for birds, plants, and aquatic macroinvertebrates) with self-reported psychological gains in well-being derived from visiting the same sites. Willingness-to-pay (WTP) estimates were significant and positive, and respondents reported high gains in well-being across 3 axes derived from environmental psychology theories (reflection, attachment, continuity with past). The 2 metrics were broadly congruent. Participants with above-median self-reported well-being scores were willing to pay significantly higher amounts for enhancing species richness than those with below-median scores, regardless of taxon. The socio-economic and demographic background of participants played little role in determining either their well-being or the probability of choosing a paying option within the choice experiment. Site-level environmental characteristics were only somewhat related to WTP, but showed strong associations with self-reported well-being. Both approaches are likely to reflect a combination of the environmental properties of a site and unobserved individual preference heterogeneity for the natural world. Our results suggest that either metric will deliver mutually consistent results in an assessment of environmental preferences, although which approach is preferable depends on why one wishes to measure values for the natural world. PMID:24372643

  14. TREAT Transient Analysis Benchmarking for the HEU Core

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kontogeorgakos, D. C.; Connaway, H. M.; Wright, A. E.

    2014-05-01

    This work was performed to support the feasibility study on the potential conversion of the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory from the use of high enriched uranium (HEU) fuel to the use of low enriched uranium (LEU) fuel. The analyses were performed by the GTRI Reactor Conversion staff at the Argonne National Laboratory (ANL). The objective of this study was to benchmark the transient calculations against temperature-limited transients performed in the final operating HEU TREAT core configuration. The MCNP code was used to evaluate steady-state neutronics behavior, and the point kinetics code TREKIN was used tomore » determine core power and energy during transients. The first part of the benchmarking process was to calculate with MCNP all the neutronic parameters required by TREKIN to simulate the transients: the transient rod-bank worth, the prompt neutron generation lifetime, the temperature reactivity feedback as a function of total core energy, and the core-average temperature and peak temperature as a functions of total core energy. The results of these calculations were compared against measurements or against reported values as documented in the available TREAT reports. The heating of the fuel was simulated as an adiabatic process. The reported values were extracted from ANL reports, intra-laboratory memos and experiment logsheets and in some cases it was not clear if the values were based on measurements, on calculations or a combination of both. Therefore, it was decided to use the term “reported” values when referring to such data. The methods and results from the HEU core transient analyses will be used for the potential LEU core configurations to predict the converted (LEU) core’s performance.« less

  15. IR spectra and properties of solid acetone, an interstellar and cometary molecule

    NASA Astrophysics Data System (ADS)

    Hudson, Reggie L.; Gerakines, Perry A.; Ferrante, Robert F.

    2018-03-01

    Mid-infrared spectra of amorphous and crystalline acetone are presented along with measurements of the refractive index and density for both forms of the compound. Infrared band strengths are reported for the first time for amorphous and crystalline acetone, along with IR optical constants. Vapor pressures and a sublimation enthalpy for crystalline acetone also are reported. Positions of 13C-labeled acetone are measured. Band strengths are compared to gas-phase values and to the results of a density-functional calculation. A 73% error in previous work is identified and corrected.

  16. Determination of the STIS CCD Gain

    NASA Astrophysics Data System (ADS)

    Riley, Allyssa; Monroe, TalaWanda; Lockwood, Sean

    2016-09-01

    This report summarizes the analysis and absolute gain results of the STIS Cycle 23 special calibration program 14424 that was designed to measure the gain of amplifiers A, C and D at nominal gain settings of 1 and 4 e-/DN. We used the mean-variance technique and the results indicate a <3.5% change in the gain for amplifier D from when it was originally calculated pre-flight. We compared these values to previous measurements from Cycles 17 through 23. This report outlines the observations, methodology, and results of the mean-variance technique.

  17. Prospective 15-year study of neuromuscular function in a cohort of patients with prior poliomyelitis.

    PubMed

    Daube, Jasper R; Sorenson, Eric J; Windebank, Anthony J

    2009-01-01

    Poliomyelitis is a monophasic illness affecting lower motor neurons and individuals may describe new problems years after the initial weakness. We have studied 38 people with the post-polio syndrome over a 15-year period assessing a number of neuromuscular measures, including motor unit number estimation (MUNE). Twenty-five individuals reported progressive weakness but there was no objective change in MUNE and other measures. There was an association with reported weakness and initial deficits. There was a slow decline in MUNE values over time in both groups.

  18. Determination of the Sampler Type and Rainfall Effect on the Deposition Fluxes of the Polychlorinated Biphenyls

    PubMed Central

    Birgül, Askin; Tasdemir, Yücel

    2012-01-01

    Atmospheric concentration and deposition samples were collected between June 2008 and June 2009 in an urban sampling site Yavuzselim, Turkey. Eighty-three polychlorinated biphenyl (PCB) congeners were targeted in the collected samples. It was found that 90% of the total PCB concentration was in the gas phase. Deposition samples were collected by a wet-dry deposition sampler (WDDS) and a bulk deposition sampler (BDS). Average total deposition fluxes measured with the BDS in dry periods was 5500 ± 2400 pg/(m2day); average dry deposition fluxes measured by the WDDS in the same period were 6400 ± 3300 pg/(m2day). The results indicated that the sampler type affected the measured flux values. Bulk deposition samples were also collected in rainy periods by using the BDS and the average flux value was 8700 ± 3100 pg/(m2day). The measured flux values were lower than the values reported for the urban and industrial areas. Dry deposition velocities for the WDDS and BDS samples were calculated 0.48 ± 0.35 cm/s and 0.13 ± 0.15 cm/s, respectively. PMID:22629199

  19. Mediterranean Environmental Acoustic Data Catalog

    DTIC Science & Technology

    1975-05-01

    kH.z. (C) SACLANT ASW Centre returned to the Tyrrhenian Sea to an area previously reported by Hastrup and Lallement to conduct extended tests uhich...were reported in 1962 by Hastrup . In these tests both explosive charges and an AN/SQS-26 sonar were used as sources, with a shallow suspended hydrophone...bottom at the point of reflection. The measured bottom reflection loss values in these tests agreed with the previously reported tests ( Hastrup and

  20. B (e 2 ;21+→01+) value in 90Kr

    NASA Astrophysics Data System (ADS)

    Régis, J.-M.; Jolie, J.; Saed-Samii, N.; Warr, N.; Pfeiffer, M.; Blanc, A.; Jentschel, M.; Köster, U.; Mutti, P.; Soldner, T.; Simpson, G. S.; Drouet, F.; Vancraeyenest, A.; de France, G.; Clément, E.; Stezowski, O.; Ur, C. A.; Urban, W.; Regan, P. H.; Podolyák, Zs.; Larijani, C.; Townsley, C.; Carroll, R.; Wilson, E.; Fraile, L. M.; Mach, H.; Paziy, V.; Olaizola, B.; Vedia, V.; Bruce, A. M.; Roberts, O. J.; Smith, J. F.; Kröll, T.; Hartig, A.-L.; Ignatov, A.; Ilieva, S.; Thürauf, M.; Lalkovski, S.; Ivanova, D.; Kisyov, S.; Korten, W.; Salsac, M.-D.; Zielińska, M.; Mǎrginean, N.; Ghitǎ, D. G.; Licǎ, R.; Petrache, C. M.; Astier, A.; Leguillon, R.

    2014-12-01

    A smooth onset of collectivity in 88 ,92 ,94 ,96Kr has been determined from reported B (E 2 ;21+→01+) and E (21+) values. This is in contrast to the sudden onset in even-even Zr, Mo, and Sr isotopes. Our objective was to complete the systematics by determining the B (E 2 ;21+→01+) value in 90Kr, which was produced by cold-neutron-induced fission of 235U . The lifetime of the 21+ state in 90Kr was measured via the electronic γ -γ timing technique using the EXILL and FATIMA spectrometers. Based on the measured mean lifetime of τ = 15(10) ps, the B (E 2 ;21+→01+) value of 13 -5+26 W.u. in 90Kr is determined for the first time and the smooth onset of deformation in the even-even Kr isotopes beyond neutron number N =50 is confirmed.

  1. Absolute Rayleigh scattering cross sections of gases and freons of stratospheric interest in the visible and ultraviolet regions

    NASA Technical Reports Server (NTRS)

    SHARDANAND; Rao, A. D. P.

    1977-01-01

    The laboratory measurements of absolute Rayleigh scattering cross sections as a function wavelength are reported for gas molecules He, Ne, Ar, N2, H2, O2, CO2, CH4 and for vapors of most commonly used freons CCl2F2, CBrF3, CF4, and CHClf2. These cross sections are determined from the measurements of photon scattering at an angle of 54 deg 44 min which yield the absolute values independent of the value of normal depolarization ratios. The present results show that in the spectral range 6943-3638A deg, the values of the Rayleigh scattering cross section can be extrapolated from one wavelength to the other using 1/lambda (4) law without knowing the values of the polarizabilities. However, such an extrapolation can not be done in the region of shorter wavelengths.

  2. A cross-country Exchange Market Pressure (EMP) dataset.

    PubMed

    Desai, Mohit; Patnaik, Ila; Felman, Joshua; Shah, Ajay

    2017-06-01

    The data presented in this article are related to the research article titled - "An exchange market pressure measure for cross country analysis" (Patnaik et al. [1]). In this article, we present the dataset for Exchange Market Pressure values (EMP) for 139 countries along with their conversion factors, ρ (rho). Exchange Market Pressure, expressed in percentage change in exchange rate, measures the change in exchange rate that would have taken place had the central bank not intervened. The conversion factor ρ can interpreted as the change in exchange rate associated with $1 billion of intervention. Estimates of conversion factor ρ allow us to calculate a monthly time series of EMP for 139 countries. Additionally, the dataset contains the 68% confidence interval (high and low values) for the point estimates of ρ 's. Using the standard errors of estimates of ρ 's, we obtain one sigma intervals around mean estimates of EMP values. These values are also reported in the dataset.

  3. Comparison of self-reported and audiometrically-measured hearing loss in the Australian Defence Force.

    PubMed

    Kirk, Katherine M; McGuire, Annabel; Nasveld, Peter E; Treloar, Susan A

    2012-04-01

    To investigate the relationship between self-reported and audiometrically-measured hearing loss in a sample of Australian Defence Force personnel. Responses to a question regarding hearing problems were compared with contemporaneous audiometric data. 3335 members of the Australian Defence Force for whom anonymised medical records were available. The sensitivity of self-report data to identify higher-frequency hearing loss was lower than sensitivity at other frequencies, and positive predictive values were moderate to poor at all frequencies. Performance characteristics of self-report compared with audiometric data also varied with age, sex, and rank. While self-report hearing loss data have good performance characteristics for estimating prevalence of hearing loss as defined by audiometric criteria, this study indicates that the usefulness of self-report data in identifying individuals with hearing loss may be limited in this population.

  4. Value-based cleft lip-cleft palate care: a progress report.

    PubMed

    Abbott, Megan M; Meara, John G

    2010-09-01

    The health care debate in the United States centers on a concept that is fundamental to any service-based profession yet minimally integrated into the health care community: value creation. Value in health care has been defined as outcome achieved per dollar spent, and focuses on the patient. Many of the new strategies proposed to restructure health care delivery in the United States aim to study and improve both components of this equation. Indeed, it is a near guarantee that providers will soon be responsible for reporting their outcomes and resource use and will be benchmarked by these metrics. In addition, patients have a right to understand the value they receive from their care providers. In this report, the authors evaluate the current state of preparedness for the assessment of value in care delivery in the field of cleft lip-cleft palate based on literature review. There has been important progress in the definition and assessment of basic outcomes in cleft lip-cleft palate care, largely through formation of intercenter collaborations. However, many fundamental challenges face the cleft community, especially in North America. Standardization of data collection and outcomes measurement and reporting are particularly lacking. In addition, few data exist regarding the cost of cleft care. The weight of the evidence reveals that the cleft community is not prepared to assess, and thus improve, the value offered to patients. The authors address key challenges and outline future directions.

  5. Absolute ozone absorption cross section in the Huggins Chappuis minimum (350-470 nm) at 296 K

    NASA Astrophysics Data System (ADS)

    Axson, J. L.; Washenfelder, R. A.; Kahan, T. F.; Young, C. J.; Vaida, V.; Brown, S. S.

    2011-08-01

    We report the ozone absolute absorption cross section between 350-470 nm, the minimum between the Huggins and Chappuis bands, where the ozone cross section is less than 10-22 cm2. Ozone spectra were acquired using an incoherent broadband cavity enhanced absorption spectrometer, with three channels centered at 365, 405, and 455 nm. The accuracy of the measured cross section is 2 %. Previous measurements vary by more than an order of magnitude in this spectral region. The measurements reported here provide much greater spectral coverage than the most recent measurements. We report a minimum absorption cross section of 3.4×10-24 cm2 at 381.8 nm, which is 22 % lower than the previously reported value. The effect of O3 concentration and water vapor partial pressure were investigated, however there were no observable changes in the absorption spectrum most likely due to the low optical density of the complex.

  6. The measurement of radiation exposure of astronauts by radiochemical techniques

    NASA Technical Reports Server (NTRS)

    Brodzinski, R. L.

    1971-01-01

    The concentrations of 23 major, minor, and trace elements in the fecal samples from the Apollo 12 and 13 astronauts are reported. Most elemental excretion rates are comparable to rates reported for earlier missions. Exceptions are noted for calcium, iron, and tin. Body calcium and iron losses appear to be reduced during the Apollo 12 and 13 missions such that losses now seem to be insignificant. Refined measurements of tin excretion rates agree with normal dietary intakes. Earlier reported tin values are in error. A new passive dosimetry canister was designed which contains foils of tantalum, copper, titanium, iron, cobalt, aluminum, and scandium. By measuring the concentrations of the various products of nuclear reactions in these metals after space exposure, the characteristics of the incident cosmic particles can be determined.

  7. Developmental Trajectories of Acculturation: Links with Family Functioning and Mental Health in Recent-Immigrant Hispanic Adolescents

    PubMed Central

    Schwartz, Seth J.; Unger, Jennifer B.; Zamboanga, Byron L.; Córdova, David; Mason, Craig A.; Huang, Shi; Baezconde-Garbanati, Lourdes; Lorenzo-Blanco, Elma I.; Des Rosiers, Sabrina; Soto, Daniel W.; Villamar, Juan A.; Pattarroyo, Monica; Lizzi, Karina M.; Szapocznik, José

    2014-01-01

    The present study was designed to examine acculturative changes, and their effects on mental health and family functioning, in recent-immigrant Hispanic adolescents. A sample of 302 Hispanic adolescents was assessed five times over a 2½-year period. Participants completed measures of Hispanic and U.S. practices, collectivist and individualist values, and ethnic and U.S. identity at each timepoint. Baseline and Time 5 levels of mental health and family functioning were also assessed. Latent class growth analyses produced two-class solutions for practices, values, and identifications. Adolescents who increased over time in practices and values reported the most adaptive mental health and family functioning. Adolescents who did not change in any acculturation domain reported the least favorable mental health and family functioning. PMID:25644262

  8. Stakeholder Engagement in a Patient-Reported Outcomes (PRO) Measure Implementation: A Report from the SAFTINet Practice-based Research Network (PBRN).

    PubMed

    Kwan, Bethany M; Sills, Marion R; Graham, Deborah; Hamer, Mika K; Fairclough, Diane L; Hammermeister, K E; Kaiser, Alicyn; de Jesus Diaz-Perez, Maria; Schilling, Lisa M

    2016-01-01

    Patient-reported outcome (PRO) measures offer value for clinicians and researchers, although priorities and value propositions can conflict. PRO implementation in clinical practice may benefit from stakeholder engagement methods to align research and clinical practice stakeholder perspectives. The objective is to demonstrate the use of stakeholder engagement in PRO implementation. Engaged stakeholders represented researchers and clinical practice representatives from the SAFTINet practice-based research network (PBRN). A stakeholder engagement process involving iterative analysis, deliberation, and decision making guided implementation of a medication adherence PRO measure (the Medication Adherence Survey [MAS]) for patients with hypertension and/or hyperlipidemia. Over 9 months, 40 of 45 practices (89%) implemented the MAS, collecting 3,247 surveys (mean = 72, median = 30, range: 0 - 416). Facilitators included: an electronic health record (EHR) with readily modifiable templates; existing staff, tools and workflows in which the MAS could be integrated (e.g., health risk appraisals, hypertension-specific visits, care coordinators); and engaged leadership and quality improvement teams. Stakeholder engagement appeared useful for promoting PRO measure implementation in clinical practice, in a way that met the needs of both researchers and clinical practice stakeholders. Limitations of this approach and opportunities for improving the PRO data collection infrastructure in PBRNs are discussed. © Copyright 2016 by the American Board of Family Medicine.

  9. 40 CFR 98.466 - Data reporting requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... from Table TT-1 to this subpart, a measured value using a 60-day anaerobic biodegradation test as... § 98.464(b)(4)(ii). If DOCX was determined by a 60-day anaerobic biodegradation test, specify the test...

  10. Revised values for the thermodynamic properties of boehmite, AlO(OH) , and related species and phases in the system Al-H-O

    USGS Publications Warehouse

    Hemingway, B.S.; Robie, R.A.; Apps, J.A.

    1991-01-01

    Heat capacity measurements are reported for a well-characterized boehmite that differ significantly from results reported earlier by Shomate and Cook (1946) for a monohydrate of alumina. It is suggested that the earlier measurements were made on a sample that was a mixture of phases and that use of that heat-capacity and derived thermodynamic data be discontinued. The entropy of boehmite derived in this study is 37.19 ?? 0.10 J/(mol.K) at 298.15 K. Based on our value for the entropy and accepting the recommended Gibbs free energy for Al(OH)-4, the Gibbs free energy and enthalpy of formation of boehmite are calculated to be -918.4 ?? 2.1 and -996.4 ?? 2.2 kJ/mol, respectively, from solubility data for boehmite. The Gibbs energy for boehmite is unchanged from that given by Hemingway et al. (1978). -from Authors

  11. Determination of gaseous fission product yields from 14 MeV neutron induced fission of 238U at the National Ignition Facility

    DOE PAGES

    Cassata, W. S.; Velsko, C. A.; Stoeffl, W.; ...

    2016-01-14

    We determined fission yields of xenon ( 133mXe, 135Xe, 135mXe, 137Xe, 138Xe, and 139Xe) resulting from 14 MeV neutron induced fission of depleted uranium at the National Ignition Facility. Measurements begin approximately 20 s after shot time, and yields have been determined for nuclides with half-lives as short as tens of seconds. We determined the relative independent yields of 133mXe, 135Xe, and 135mXe to significantly higher precision than previously reported. The relative fission yields of all nuclides are statistically indistinguishable from values reported by England and Rider (ENDF-349. LA-UR-94-3106, 1994), with exception of the cumulative yield of 139Xe. Furthermore, considerablemore » differences exist between our measured yields and the JEFF-3.1 database values.« less

  12. Final report on key comparison APMP.M.P-K13 in hydraulic gauge pressure from 50 MPa to 500 MPa

    NASA Astrophysics Data System (ADS)

    Kajikawa, Hiroaki; Kobata, Tokihiko; Yadav, Sanjay; Jian, Wu; Changpan, Tawat; Owen, Neville; Yanhua, Li; Hung, Chen-Chuan; Ginanjar, Gigin; Choi, In-Mook

    2015-01-01

    This report describes the results of a key comparison of hydraulic high-pressure standards at nine National Metrology Institutes (NMIs: NMIJ/AIST, NPLI, NMC/A*STAR, NIMT, NMIA, NIM, CMS/ITRI, KIM-LIPI, and KRISS) within the framework of the Asia-Pacific Metrology Programme (APMP) in order to determine their degrees of equivalence in the pressure range from 50 MPa to 500 MPa in gauge mode. The pilot institute was the National Metrology Institute of Japan (NMIJ/AIST). All participating institutes used hydraulic pressure balances as their pressure standards. A set of pressure balance with a free-deformational piston-cylinder assembly was used as the transfer standard. Three piston-cylinder assemblies, only one at a time, were used to complete the measurements in the period from November 2010 to January 2013. Ten participants completed their measurements and reported the pressure-dependent effective areas of the transfer standard at specified pressures with the associated uncertainties. Since one of the participants withdrew its results, the measurement results of the nine participants were finally compared. The results were linked to the CCM.P-K13 reference values through the results of two linking laboratories, NMIJ/AIST and NPLI. The degrees of equivalence were evaluated by the relative deviations of the participants' results from the CCM.P-K13 key comparison reference values, and their associated combined expanded (k=2) uncertainties. The results of all the nine participating NMIs agree with the CCM.P-K13 reference values within their expanded (k=2) uncertainties in the entire pressure range from 50 MPa to 500 MPa. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  13. Estimating new production in the equatorial Pacific Ocean at 150 deg W

    NASA Technical Reports Server (NTRS)

    Dugdale, Richard C.; Wilkerson, Frances P.; Barber, Richard T.; Chavez, Francisco P.

    1992-01-01

    A major goal of the WEC88 cruise of the R/V Wecoma to the equatorial Pacific (made in February-March 1988) was to establish rates of new production along a meridional section at 150 deg W and to compare these measured rates with the relatively high values for the equatorial Pacific that had been reported previously using indirect methods and models. Production values were obtained from the traditional approach using N-15 labeled nitrate uptake, and by using C-14 fixation values multiplied by f (proportion of new production) from various sources: from N-15 data, from a C-14 fixation-versus-f relationship, or from a nitrate-versus-f relationship. The ratios of directly measured nitrate and carbon uptake and the ratios of nitrate to nitrate plus ammonium uptake, i.e., values of f, agree well; values of f calculated from carbon uptake or from nitrate concentration are overestimates for the equatorial upwelling region. Carbon-to-nitrogen uptake ratios measured with C-14 and N-15, respectively, approximate the Redfield molar ratio, 6.6 C:N. The overall mean value of f (0.17) helps confirm the view that the low primary production in the enriched eastern equatorial Pacific is due to failure of the nitrate-uptake system.

  14. Value Based Care and Patient-Centered Care: Divergent or Complementary?

    PubMed

    Tseng, Eric K; Hicks, Lisa K

    2016-08-01

    Two distinct but overlapping care philosophies have emerged in cancer care: patient-centered care (PCC) and value-based care (VBC). Value in healthcare has been defined as the quality of care (measured typically by healthcare outcomes) modified by cost. In this conception of value, patient-centeredness is one important but not necessarily dominant quality measure. In contrast, PCC includes multiple domains of patient-centeredness and places the patient and family central to all decisions and evaluations of quality. The alignment of PCC and VBC is complicated by several tensions, including a relative lack of patient experience and preference measures, and conceptions of cost that are payer-focused instead of patient-focused. Several strategies may help to align these two philosophies, including the use of patient-reported outcomes in clinical trials and value determinations, and the purposeful integration of patient preference in clinical decisions and guidelines. Innovative models of care, including accountable care organizations and oncology patient-centered medical homes, may also facilitate alignment through improved care coordination and quality-based payment incentives. Ultimately, VBC and PCC will only be aligned if patient-centered outcomes, perspectives, and preferences are explicitly incorporated into the definitions and metrics of quality, cost, and value that will increasingly influence the delivery of cancer care.

  15. Microwave response of high transition temperature superconducting thin films

    NASA Technical Reports Server (NTRS)

    Miranda, Felix Antonio

    1991-01-01

    We have studied the microwave response of YBa2Cu3O(7 - delta), Bi-Sr-Ca-Cu-O, and Tl-Ba-Ca-Cu-O high transition temperature superconducting (HTS) thin films by performing power transmission measurements. These measurements were carried out in the temperature range of 300 K to 20 K and at frequencies within the range of 30 to 40 GHz. Through these measurements we have determined the magnetic penetration depth (lambda), the complex conductivity (sigma(sup *) = sigma(sub 1) - j sigma(sub 2)) and the surface resistance (R(sub s)). An estimate of the intrinsic penetration depth (lambda approx. 121 nm) for the YBa2Cu3O(7 - delta) HTS has been obtained from the film thickness dependence of lambda. This value compares favorably with the best values reported so far (approx. 140 nm) in single crystals and high quality c-axis oriented thin films. Furthermore, it was observed that our technique is sensitive to the intrinsic anisotropy of lambda in this superconductor. Values of lambda are also reported for Bi-based and Tl-based thin films. We observed that for the three types of superconductors, both sigma(sub 1) and sigma(sub 2) increased when cooling the films below their transition temperature. The measured R(sub s) are in good agreement with other R(sub S) values obtained using resonant activity techniques if we assume a quadratic frequency dependence. Our analysis shows that, of the three types of HTS films studied, the YBa2Cu3O(7 - delta) thin film, deposited by laser ablation and off-axis magnetron sputtering are the most promising for microwave applications.

  16. Determination of the sulfur isotope ratio in carbonyl sulfide using gas chromatography/isotope ratio mass spectrometry on fragment ions 32S+, 33S+, and 34S+.

    PubMed

    Hattori, Shohei; Toyoda, Akari; Toyoda, Sakae; Ishino, Sakiko; Ueno, Yuichiro; Yoshida, Naohiro

    2015-01-06

    Little is known about the sulfur isotopic composition of carbonyl sulfide (OCS), the most abundant atmospheric sulfur species. We present a promising new analytical method for measuring the stable sulfur isotopic compositions (δ(33)S, δ(34)S, and Δ(33)S) of OCS using nanomole level samples. The direct isotopic analytical technique consists of two parts: a concentration line and online gas chromatography-isotope ratio mass spectrometry (GC-IRMS) using fragmentation ions (32)S(+), (33)S(+), and (34)S(+). The current levels of measurement precision for OCS samples greater than 8 nmol are 0.42‰, 0.62‰, and 0.23‰ for δ(33)S, δ(34)S, and Δ(33)S, respectively. These δ and Δ values show a slight dependence on the amount of injected OCS for volumes smaller than 8 nmol. The isotope values obtained from the GC-IRMS method were calibrated against those measured by a conventional SF6 method. We report the first measurement of the sulfur isotopic composition of OCS in air collected at Kawasaki, Kanagawa, Japan. The δ(34)S value obtained for OCS (4.9 ± 0.3‰) was lower than the previous estimate of 11‰. When the δ(34)S value for OCS from the atmospheric sample is postulated as the global signal, this finding, coupled with isotopic fractionation for OCS sink reactions in the stratosphere, explains the reported δ(34)S for background stratospheric sulfate. This suggests that OCS is a potentially important source for background (nonepisodic or nonvolcanic) stratospheric sulfate aerosols.

  17. Central-To-Peripheral Arterial Stiffness Gradient in Hemodialyzed Patients Depends on the Location of the Upper-limb Vascular Access.

    PubMed

    Bia, Daniel; Galli, Cintia; Zocalo, Yanina; Valtuille, Rodolfo; Wray, Sandra; Pessana, Franco; Cabrera-Fischer, Edmundo I

    2018-04-13

    Pulse wave velocity ratio (PWV-ratio), a measure of central-to-peripheral arterial stiffness gradient, is calculated as a quotient between carotid-femoral and carotid-radial PWV (cf-PWV/cr-PWV). This new index has been reported to be significantly associated with increased mortality in hemodialyzed patients. Since several reports showed differences in arterial stiffness regarding the pathway where the vascular access (VA) is, the purpose of this research was: a) to compare arterial stiffness values obtained in the left and right sides of the body in hemodialyzed and non-hemodialyzed patients, and b) to analyze PWV-ratio values obtained in the side of the body where the VA was placed and compare them to its contralateral intact side. Since it is difficult to adequately measure cr-PWV in patients with a VA in the forearm, we measured the carotid-brachial PWV (cb-PWV) and used it to calculate PWV-ratio (cf-PWV/cb-PWV). A Pearson's correlation and Bland & Altman analysis were performed in hemodialyzed (n=135) and non-hemodialyzed (n=77) patients, to quantify the equivalence between arterial stiffness parameters (cf-PWV, cb-PWV, PWV-ratio) obtained in each side of the body with respect to its contralateral side. We conclude that PWV-ratio values measured in the side where the VA is placed were significantly higher than those obtained in its contralateral side, in hemodialyzed patients included in this research. Moreover, cf-PWV, cb-PWV and PWV-ratio values obtained in one side of the body were always highly correlated with its contralateral side. According to this research, any research involving PWV-ratio should always consider the observed territory. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  18. Effects of premium discount on workers' compensation claims in agriculture in Finland.

    PubMed

    Rautiainen, Risto H; Ledolter, Johannes; Sprince, Nancy L; Donham, Kelley J; Burmeister, Leon F; Ohsfeldt, Robert; Reynolds, Stephen J; Phillips, Kirk; Zwerling, Craig

    2005-08-01

    The objective of this study was to measure changes in injury claim rates after a premium discount program was implemented in the Finnish farmers' workers' compensation insurance. We focused on measures that could indicate whether the changes occurred in the true underlying injury rate, or only in claims reporting. Monthly injury claim rates were constructed at seven disability duration levels from January 1990 to December 2003. We conducted interrupted time series analyses to measure changes in the injury claim rates after the premium discount was implemented on July 1, 1997. Three additional policy change indicators were included in the analyses. The overall injury claim rate decreased 10.2%. Decreases occurred at four severity levels (measured by compensated disability days): 0 days (16.3%), 1-6 days (14.1%), 7-13 days (19.5%), and 14-29 days (8.4%). No changes were observed at higher severity levels. Minor injuries had a seasonal pattern with higher rates in summer months while severe injuries did not have a seasonal pattern. The premium discount decreased the overall claim rate. Decreases were observed in all categories up to 29 disability days. This pattern suggests that under-reporting contributes to the decrease but may not be the only factor. The value of the premium discount is lower than the value of a lost-time claim, so there was no financial reason to under-report lost-time injuries. Under-reporting would be expected to be greatest in the 0 day category, but that was not the case. These observations suggest that in addition to under-reporting, the premium discount may also have some preventive effect. Copyright (c) 2005 Wiley-Liss, Inc.

  19. Spin Seebeck effect in a weak ferromagnet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arboleda, Juan David, E-mail: juan.arboledaj@udea.edu.co; Arnache Olmos, Oscar; Aguirre, Myriam Haydee

    2016-06-06

    We report the observation of room temperature spin Seebeck effect (SSE) in a weak ferromagnetic normal spinel Zinc Ferrite (ZFO). Despite the weak ferromagnetic behavior, the measurements of the SSE in ZFO show a thermoelectric voltage response comparable with the reported values for other ferromagnetic materials. Our results suggest that SSE might possibly originate from the surface magnetization of the ZFO.

  20. Review of in-service moisture and temperature conditions in wood-frame buildings

    Treesearch

    Samuel V. Glass; Anton TenWolde

    2007-01-01

    This literature review reports in-service moisture and temperature conditions of floor, wall, and roof members of wood-frame buildings and exposed wood decks and permanent wood foundations. A wide variation exists in reported wood moisture content, spanning a range from as low as 2% to well above 30%. Relevant studies are summarized, and measured values of wood...

  1. The Relationship between Components of the Ohio Local School District Report Card and the Outcome of a School Tax Levy

    ERIC Educational Resources Information Center

    Wheatley, Vicki Ann

    2012-01-01

    The relationship between components of the local school district report card, school district typology, and the outcome of public school tax levy requests were examined in this study. A correlation research design was used to measure the relationship between the independent variables (performance index, average yearly progress, value added,…

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sivaraman, Chitra

    The purpose of this report is to provide a concise status update for value-added products (VAP) implemented by the Atmospheric Radiation Measurement Climate Research Facility. The report is divided into the following sections: (1) new VAPs for which development has begun, (2) progress on existing VAPs, (3) future VAPs that have been recently approved, (4) other work that leads to a VAP, and (5) top requested VAPs from the archive.

  3. Assigning a Socio-Economic Status Value to Student Records: A Useful Tool for Planning, Reporting and Institutional Research

    ERIC Educational Resources Information Center

    Delaney, Julie; Tangtulyangkul, Ploy; McCormack, Robert

    2013-01-01

    In an educational context, the accurate determination of each student's socioeconomic status (SES) is important for planning, reporting and general institutional research. This article describes a project undertaken to develop the means to derive a proxy measure of students' SES, based on home address location and Australian Bureau of Statistics…

  4. Family Physician Readiness for Value-Based Payments: Does Ownership Status Matter?

    PubMed

    Robertson-Cooper, Heidy; Neaderhiser, Bradley; Happe, Laura E; Beveridge, Roy A

    2017-10-01

    Value-based payments are rapidly replacing fee-for-service arrangements, necessitating advancements in physician practice capabilities and functions. The objective of this study was to examine potential differences among family physicians who are owners versus employed with respect to their readiness for value-based payment models. The authors surveyed more than 550 family physicians from the American Academy of Family Physician's membership; nearly 75% had made changes to participate in value-based payments. However, owners were significantly more likely to report that their practices had made no changes in value-based payment capabilities than employed physicians (owners 35.2% vs. employed 18.1%, P < 0.05). This study identified 3 key areas in which physician owners' value-based practice capabilities were not as advanced as the employed physician group: (1) quality improvement strategies, (2) human capital investment, and (3) identification of high-risk patients. Specifically, the employed physician group reported more quality improvement strategies, including quality measures, Plan-Do-Study-Act, root cause analysis, and Lean Six Sigma (P < 0.05 for all). More employed physicians reported that their practices had full-time care management staff (19.8% owners vs. 30.8% employed, P < 0.05), while owners were more likely to report that they had no resources/capacity to hire care managers or care coordinators (31.4% owners vs. 19.4% employed, P < 0.05). Owners were significantly more likely to respond that they do not have the resources/capacity to identify high-risk patients (23.1% owners vs. 19.3% employed, P < 0.05). As public and private payers transition to value-based payments, consideration of different population health management needs according to ownership status has the potential to support the adoption of value-based care delivery for family physicians.

  5. An assessment of cultural values and resident-centered culture change in U.S. nursing facilities.

    PubMed

    Banaszak-Holl, Jane; Castle, Nicholas G; Lin, Michael; Spreitzer, Gretchen

    2013-01-01

    Culture change initiatives propose to improve care by addressing the lack of managerial supports and prevalent stressful work environments in the industry; however, little is known about how culture change facilities differ from facilities in the industry that have not chosen to affiliate with the resident-centered care movements. The aim of this study was to evaluate representation of organizational culture values within a random sample of U.S. nursing home facilities using the competing values framework and to determine whether organizational values are related to membership in resident-centered culture change initiatives. We collected reports of cultural values using a well-established competing values framework instrument in a random survey of facility administrators and directors of nursing within all states. We received responses from 57% of the facilities that were mailed the survey. Directors of nursing and administrators did not differ significantly in their reports of culture and facility measures combined their responses. Nursing facilities favored market-focused cultural values on average, and developmental values, key to innovation, were the least common across all nursing homes. Approximately 17% of the facilities reported that all cultural values were strong within their facilities. Only high developmental cultural values were linked to participation in culture change initiatives. Culture change facilities were not different from non-culture change facilities in the promotion of employee focus as organizational culture, as emphasized in group culture values. Likewise, culture change facilities were also not more likely to have hierarchical or market foci than non-culture change facilities. Our results counter the argument that culture change facilities have a stronger internal employee focus than facilities more generally but do show that culture change facilities report stronger developmental cultures than non-culture change facilities, which indicates a potential to be innovative in their strategies. Facilities are culturally ready to become resident centered and may face other barriers to adopting these practices.

  6. Unbound bilirubin measurements by a novel probe in preterm infants.

    PubMed

    Hegyi, Thomas; Kleinfeld, Alan; Huber, Andrew; Weinberger, Barry; Memon, Naureen; Shih, Weichung; Carayannopoulos, Mary; Oh, William

    2018-03-12

    Hyperbilirubinemia occurs in over 80% of newborns and severe bilirubin toxicity can lead to neurological dysfunction and death, especially in preterm infants. Currently, the risk of bilirubin toxicity is assessed by measuring the levels of total serum bilirubin (TSB), which are used to direct treatments including immunoglobulin administration, phototherapy, and exchange transfusion. However, free, unbound bilirubin levels (Bf) predict the risk of bilirubin neurotoxicity more accurately than TSB. To examine Bf levels in preterm infants and determine the frequency with which they exceed reported neurotoxic thresholds. One hundred thirty preterm infants (BW 500-2000 g; GA 23-34 weeks) were enrolled and Bf levels measured during the first week of life by the fluorescent Bf sensor BL22P1B11-Rh. TSB and plasma albumin were measured by standard techniques. Bilirubin-albumin dissociation constants (K d ) were calculated based on Bf and plasma albumin. Five hundred eighty samples were measured during the first week of life, with an overall mean Bf of 13.6 ± 9.0 nM. A substantial number of measurements exceeded potential toxic thresholds levels as reported in the literature. The correlation between Bf and TSB was statistically significant (r 2 0.17), but this weak relationship was lost at high Bf levels. Infants <28-week gestations had more hearing screening failures than infants ≥28-week gestation. Unbound (free) bilirubin values are extremely variable during the first week of life in preterm infants. A significant proportion of these values exceeded reported neurotoxic thresholds.

  7. Internal friction quality-factor Q under confining pressure. [of lunar rocks

    NASA Technical Reports Server (NTRS)

    Tittmann, B. R.; Ahlberg, L.; Nadler, H.; Curnow, J.; Smith, T.; Cohen, E. R.

    1977-01-01

    It has been found in previous studies that small amounts of adsorbed volatiles can have a profound effect on the internal friction quality-factor Q of rocks and other porous media. Pandit and Tozer (1970) have suggested that the laboratory-measured Q of volatile-free rocks should be similar to the in situ seismic Q values of near-surface lunar rocks which according to Latham et al. (1970) are in the range of 3000-5000. Observations of dramatic increases in Q with outgassing up to values approaching 2000 in the seismic frequency range confirm this supposition. Measurements under confining pressures with the sample encapsulated under hard vacuum are reported to aid in the interpretation of seismic data obtained below the lunar surface. It has been possible to achieve in the experiments Q values just under 2000 at about 1 kbar for a terrestrial analog of lunar basalt. It was found that a well-outgassed sample maintains a high Q whereas one exposed to moisture maintains a low Q as the confining pressure is raised to 2.5 kbar. This result suggests that volatiles can indeed affect Q when cracks are partially closed and the high lunar seismic Q values reported are concomitant with very dry rock down to depths of at least 50 km.

  8. Quantitative and descriptive comparison of four acoustic analysis systems: vowel measurements.

    PubMed

    Burris, Carlyn; Vorperian, Houri K; Fourakis, Marios; Kent, Ray D; Bolt, Daniel M

    2014-02-01

    This study examines accuracy and comparability of 4 trademarked acoustic analysis software packages (AASPs): Praat, WaveSurfer, TF32, and CSL by using synthesized and natural vowels. Features of AASPs are also described. Synthesized and natural vowels were analyzed using each of the AASP's default settings to secure 9 acoustic measures: fundamental frequency (F0), formant frequencies (F1-F4), and formant bandwidths (B1-B4). The discrepancy between the software measured values and the input values (synthesized, previously reported, and manual measurements) was used to assess comparability and accuracy. Basic AASP features are described. Results indicate that Praat, WaveSurfer, and TF32 generate accurate and comparable F0 and F1-F4 data for synthesized vowels and adult male natural vowels. Results varied by vowel for women and children, with some serious errors. Bandwidth measurements by AASPs were highly inaccurate as compared with manual measurements and published data on formant bandwidths. Values of F0 and F1-F4 are generally consistent and fairly accurate for adult vowels and for some child vowels using the default settings in Praat, WaveSurfer, and TF32. Manipulation of default settings yields improved output values in TF32 and CSL. Caution is recommended especially before accepting F1-F4 results for children and B1-B4 results for all speakers.

  9. Lidar using the backscatter amplification effect

    NASA Astrophysics Data System (ADS)

    Razenkov, Igor A.; Banakh, Victor A.

    2018-04-01

    Experimental data proving the possibility of lidar measurement of the refractive turbulence strength based on the effect of backscatter amplification (BSA) are reported. It is shown that the values of the amplification factor correlate with the variance of random jitter of optical image of an incoherent light source depending on the value of the structure constant of the air refractive index turbulent fluctuations averaged over the probing path. This paper presents the results of measurements of the BSA factor in comparison with the simultaneous measurements of the BSA peak, which is very narrow and only occurs on the laser beam axis. It is constructed the range-time images of the derivative of the amplification factor gives a comprehensive picture of the location of turbulent zones and their temporal dynamics.

  10. Direct measurement of adhesion energy of monolayer graphene as-grown on copper and its application to renewable transfer process.

    PubMed

    Yoon, Taeshik; Shin, Woo Cheol; Kim, Taek Yong; Mun, Jeong Hun; Kim, Taek-Soo; Cho, Byung Jin

    2012-03-14

    Direct measurement of the adhesion energy of monolayer graphene as-grown on metal substrates is important to better understand its bonding mechanism and control the mechanical release of the graphene from the substrates, but it has not been reported yet. We report the adhesion energy of large-area monolayer graphene synthesized on copper measured by double cantilever beam fracture mechanics testing. The adhesion energy of 0.72 ± 0.07 J m(-2) was found. Knowing the directly measured value, we further demonstrate the etching-free renewable transfer process of monolayer graphene that utilizes the repetition of the mechanical delamination followed by the regrowth of monolayer graphene on a copper substrate. © 2012 American Chemical Society

  11. Technical Note: Gray tracking in medical color displays-A report of Task Group 196.

    PubMed

    Badano, Aldo; Wang, Joel; Boynton, Paul; Le Callet, Patrick; Cheng, Wei-Chung; Deroo, Danny; Flynn, Michael J; Matsui, Takashi; Penczek, John; Revie, Craig; Samei, Ehsan; Steven, Peter M; Swiderski, Stan; Van Hoey, Gert; Yamaguchi, Matsuhiro; Hasegawa, Mikio; Nagy, Balázs Vince

    2016-07-01

    The authors discuss measurement methods and instrumentation useful for the characterization of the gray tracking performance of medical color monitors for diagnostic applications. The authors define gray tracking as the variability in the chromaticity of the gray levels in a color monitor. The authors present data regarding the capability of color measurement instruments with respect to their abilities to measure a target white point corresponding to the CIE Standard Illuminant D65 at different luminance values within the grayscale palette of a medical display. The authors then discuss evidence of significant differences in performance among color measurement instruments currently available for medical physicists to perform calibrations and image quality checks for the consistent representation of color in medical displays. In addition, the authors introduce two metrics for quantifying grayscale chromaticity consistency of gray tracking. The authors' findings show that there is an order of magnitude difference in the accuracy of field and reference instruments. The gray tracking metrics quantify how close the grayscale chromaticity is to the chromaticity of the full white point (equal amounts of red, green, and blue at maximum level) or to consecutive levels (equal values for red, green, and blue), with a lower value representing an improved grayscale tracking performance. An illustrative example of how to calculate and report the gray tracking performance according to the Task Group definitions is provided. The authors' proposed methodology for characterizing the grayscale degradation in chromaticity for color monitors that can be used to establish standards and procedures aiding in the quality control testing of color displays and color measurement instrumentation.

  12. Experimental radiative lifetimes, branching fractions, and oscillator strengths of some levels in Tm III

    NASA Astrophysics Data System (ADS)

    Yu, Qi; Wang, Xinghao; Li, Qiu; Gong, Yimin; Dai, Zhenwen

    2018-06-01

    Natural radiative lifetimes for five even-parity levels of Tm III were measured by time-resolved laser-induced fluorescence method. The branching fraction measurements were performed based on the emission spectra of a hollow cathode lamp. By combining the measured branching fractions and the lifetime values reported in this work and in literature, experimental transition probabilities and oscillator strengths for 11 transitions were derived for the first time.

  13. Measurements of (60)Co in massive steel samples exposed to the Hiroshima atomic bomb explosion.

    PubMed

    Gasparro, Joël; Hult, Mikael; Marissens, Gerd; Hoshi, Masaharu; Tanaka, Kenichi; Endo, Satoru; Laubenstein, Matthias; Dombrowski, Harald; Arnold, Dirk

    2012-04-01

    To study discrepancies in retrospective Hiroshima dosimetry, the specific activity of (60)Co in 16 steel samples from Hiroshima was measured using gamma-ray spectrometry in underground laboratories. There is general agreement between these new activity measurements and the specific activities derived from previously calculated dose values on the one hand and former measurements of samples gathered at distances less than 1,000 m from the center of the explosion (< 1,000 m slant range) on the other. It was found that activities at long range (> 1,300 m slant range) were mainly cosmogenically induced. Furthermore, at long range, these results are in disagreement with older measurements whose specific activity values were 10 to 100 times higher than predicted by computer model calculations in DS86 and DS02. As a consequence, the previously reported discrepancy is not confirmed.

  14. Self-Stigma in Substance Abuse: Development of a New Measure

    PubMed Central

    Luoma, Jason B.; Nobles, Richard H.; Drake, Chad E.; Hayes, Steven C.; O’Hair, Alyssa; Fletcher, Lindsay; Kohlenberg, Barbara S.

    2012-01-01

    Little attention has been paid to the examination and measurement of self-stigma in substance misuse. This paper aims to fill this gap by reporting on the development of a new scale to measure self-stigma experienced by people who are misusing substances, the Substance Abuse Self-Stigma Scale. Content validity and item refinement occurred through an iterative process involving a literature search, focus groups, and expert judges. Psychometric properties were examined in a cross-sectional study of individuals (n = 352) receiving treatment for substance misuse. Factor analyses resulted in a 40-item measure with self devaluation, fear of enacted stigma, stigma avoidance, and values disengagement subscales. The measure showed a strong factor structure and good reliability and validity overall, though the values disengagement subscale showed a mixed pattern. Results are discussed in terms of their implications for studies of stigma impact and intervention. PMID:23772099

  15. The Measurand: The Problem of Frequency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kirkham, Harold

    The conceptual entity that metrologists term the measurand is a model selected to represent the physical entity being measured. In a world of digital measurements, it should be defined first mathematically, and only then put into words. Human linguistic processes lack the precision required when all we do is use labels. In this paper, reactive power and frequency are used as examples. The act of measurement finds the values of the coef-ficients of the model. In other words, it solves an equation. In a digital instrument, information about the quality of the fit between the physical entity being measured andmore » the conceptual model is often available. In essence the instrument can comment on the selection of the model. This comment should be reported as part of the statement of the result of the measurement, along with the declared value and the uncertainty.« less

  16. Equation of state of Mo from shock compression experiments on preheated samples

    NASA Astrophysics Data System (ADS)

    Fat'yanov, O. V.; Asimow, P. D.

    2017-03-01

    We present a reanalysis of reported Hugoniot data for Mo, including both experiments shocked from ambient temperature (T) and those preheated to 1673 K, using the most general methods of least-squares fitting to constrain the Grüneisen model. This updated Mie-Grüneisen equation of state (EOS) is used to construct a family of maximum likelihood Hugoniots of Mo from initial temperatures of 298 to 2350 K and a parameterization valid over this range. We adopted a single linear function at each initial temperature over the entire range of particle velocities considered. Total uncertainties of all the EOS parameters and correlation coefficients for these uncertainties are given. The improved predictive capabilities of our EOS for Mo are confirmed by (1) better agreement between calculated bulk sound speeds and published measurements along the principal Hugoniot, (2) good agreement between our Grüneisen data and three reported high-pressure γ ( V ) functions obtained from shock-compression of porous samples, and (3) very good agreement between our 1 bar Grüneisen values and γ ( T ) at ambient pressure recalculated from reported experimental data on the adiabatic bulk modulus K s ( T ) . Our analysis shows that an EOS constructed from shock compression data allows a much more accurate prediction of γ ( T ) values at 1 bar than those based on static compression measurements or first-principles calculations. Published calibrations of the Mie-Grüneisen EOS for Mo using static compression measurements only do not reproduce even low-pressure asymptotic values of γ ( T ) at 1 bar, where the most accurate experimental data are available.

  17. [What factors of prosocial behavior evoke recipients’ gratitude and indebtedness? An experimental examination].

    PubMed

    Shiraki, Yuma; Igarashi, Tasuku

    2016-12-01

    We examined two psychological processes of prosocial behavior: feeling gratitude and indebtedness. First, we asked if the value of the behavior for the receiver promotes gratitude; and second if the cost of the behavior for the giver promotes indebtedness. Gratitude and indebtedness were measured as behavioral indices of a quid pro quo (indirect reciprocity and direct reciprocity) to avoid social desirability effects in self-report measures. In Study 1, 119 undergraduates recalled a past experience in which they had been the recipients of prosocial behavior while emphasizing the value, cost, or situation (control) of the event. The level of gratitude was higher, and indirect reciprocity was observed more frequently, in the value condition than in the cost and control conditions. Indebtedness, however, did not differ across the conditions. In Study 2, 59 participants received a gift (the value and cost of which were manipulated) from an imaginary confederate. The value manipulation promoted indirect reciprocity, and both value and cost manipulations encouraged direct reciprocity. Implications for adaptive functions of gratitude in social selection processes are discussed.

  18. Measurement Properties of Performance-Specific Pain Ratings of Patients Awaiting Total Joint Arthroplasty as a Consequence of Osteoarthritis

    PubMed Central

    Stratford, Paul W.; Kennedy, Deborah M.; Woodhouse, Linda J.; Spadoni, Gregory

    2008-01-01

    Purpose: To estimate the test–retest reliability of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain sub-scale and performance-specific assessments of pain, as well as the association between these measures for patients awaiting primary total hip or knee arthroplasty as a consequence of osteoarthritis. Methods: A total of 164 patients awaiting unilateral primary hip or knee arthroplasty completed four performance measures (self-paced walk, timed up and go, stair test, six-minute walk) and the WOMAC. Scores for 22 of these patients provided test–retest reliability data. Estimates of test–retest reliability (Type 2,1 intraclass correlation coefficient [ICC] and standard error of measurement [SEM]) and the association between measures were examined. Results: ICC values for individual performance-specific pain ratings were between 0.70 and 0.86; SEM values were between 0.97 and 1.33 pain points. ICC estimates for the four-item performance pain ratings and the WOMAC pain sub-scale were 0.82 and 0.57 respectively. The correlation between the sum of the pain scores for the four performance measures and the WOMAC pain sub-scale was 0.62. Conclusion: Reliability estimates for the performance-specific assessments of pain using the numeric pain rating scale were consistent with values reported for patients with a spectrum of musculoskeletal conditions. The reliability estimate for the WOMAC pain sub-scale was lower than typically reported in the literature. The level of association between the WOMAC pain sub-scale and the various performance-specific pain scales suggests that the scores can be used interchangeably when applied to groups but not for individual patients. PMID:20145758

  19. Development and Validation of Scores from an Instrument Measuring Student Test-Taking Motivation

    ERIC Educational Resources Information Center

    Eklof, Hanna

    2006-01-01

    Using the expectancy-value model of achievement motivation as a basis, this study's purpose is to develop, apply, and validate scores from a self-report instrument measuring student test-taking motivation. Sampled evidence of construct validity for the present sample indicates that a number of the items in the instrument could be used as an…

  20. Measuring School and Teacher Value Added for IMPACT and TEAM in DC Public Schools. Final Report

    ERIC Educational Resources Information Center

    Isenberg, Eric; Hock, Heinrich

    2010-01-01

    The District of Columbia Public Schools (DCPS) has incorporated measures of school and teacher effectiveness, based on student test score growth, into a new teacher assessment system known as IMPACT. Implemented for the first time during the 2009-2010 school year, IMPACT is an assessment system with significant consequences. Prior to the start of…

  1. Overlay accuracy with respect to device scaling

    NASA Astrophysics Data System (ADS)

    Leray, Philippe; Laidler, David; Cheng, Shaunee

    2012-03-01

    Overlay metrology performance is usually reported as repeatability, matching between tools or optics aberrations distorting the measurement (Tool induced shift or TIS). Over the last few years, improvement of these metrics by the tool suppliers has been impressive. But, what about accuracy? Using different target types, we have already reported small differences in the mean value as well as fingerprint [1]. These differences make the correctables questionable. Which target is correct and therefore which translation, scaling etc. values should be fed back to the scanner? In this paper we investigate the sources of these differences, using several approaches. First, we measure the response of different targets to offsets programmed in a test vehicle. Second, we check the response of the same overlay targets to overlay errors programmed into the scanner. We compare overlay target designs; what is the contribution of the size of the features that make up the target? We use different overlay measurement techniques; is DBO (Diffraction Based Overlay) more accurate than IBO (Image Based Overlay)? We measure overlay on several stacks; what is the stack contribution to inaccuracy? In conclusion, we offer an explanation for the observed differences and propose a solution to reduce them.

  2. [Validation of the Schizophrenia Quality Of Life Scale (SQLS) to Measure Quality of Life in Patients Diagnosed With Schizophrenia in Colombia].

    PubMed

    Suárez, María Fernanda; Sánchez, Ricardo; Calvo, José Manuel

    2013-09-01

    To validate the SQLS scale in Colombian patients diagnosed with schizophrenia. The self-report scale was applied to 251 patients. Measures of test-retest reliability, internal consistency and correlation inter-scales with the SF-12 were made by applying the scale 2 days later in 28 patients, and 30 days later in 38; 50 patients filled-out the SF-12 scale to determine the concurrent validity. Three domains were found with all of them having Cronbach's alphas >0.7. The three factors model did not show adequate fit indexes. Test-retest evaluation showed satisfactory correlation values (>0.86). Sensitivity to change did not shown significant differences between the repeated measures. As regards concurrent validity, acceptable correlation values were found only in SF-12 domains related to mental health and functioning. The SQLS has a factorial structure consistent with previous reports, adequate internal consistency and temporal stability. However, a more detailed examination of some of these items is required, considering that the measurement of the construct does not appear to be adequate. Copyright © 2013 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.

  3. Testosterone Trajectories and Reference Ranges in a Large Longitudinal Sample of Male Adolescents

    PubMed Central

    Khairullah, Ammar; Cousino Klein, Laura; Ingle, Suzanne M.; May, Margaret T.; Whetzel, Courtney A.; Susman, Elizabeth J.; Paus, Tomáš

    2014-01-01

    Purpose Pubertal dynamics plays an important role in physical and psychological development of children and adolescents. We aim to provide reference ranges of plasma testosterone in a large longitudinal sample. Furthermore, we describe a measure of testosterone trajectories during adolescence that can be used in future investigations of development. Methods We carried out longitudinal measurements of plasma testosterone in 2,216 samples obtained from 513 males (9 to 17 years of age) from the Avon Longitudinal Study of Parents and Children. We used integration of a model fitted to each participant’s testosterone trajectory to calculate a measure of average exposure to testosterone over adolescence. We pooled these data with corresponding values reported in the literature to provide a reference range of testosterone levels in males between the ages of 6 and 19 years. Results The average values of total testosterone in the ALSPAC sample range from 0.82 nmol/L (Standard Deviation [SD]: 0.09) at 9 years of age to 16.5 (SD: 2.65) nmol/L at 17 years of age; these values are congruent with other reports in the literature. The average exposure to testosterone is associated with different features of testosterone trajectories such as Peak Testosterone Change, Age at Peak Testosterone Change, and Testosterone at 17 years of age as well as the timing of the growth spurt during puberty. Conclusions The average exposure to testosterone is a useful measure for future investigations using testosterone trajectories to examine pubertal dynamics. PMID:25268961

  4. Characterization of engineered nanoparticles in commercially available spray disinfectant products advertised to contain colloidal silver.

    PubMed

    Rogers, Kim R; Navratilova, Jana; Stefaniak, Aleksandr; Bowers, Lauren; Knepp, Alycia K; Al-Abed, Souhail R; Potter, Phillip; Gitipour, Alireza; Radwan, Islam; Nelson, Clay; Bradham, Karen D

    2018-04-01

    Given the potential for human exposure to silver nanoparticles from spray disinfectants and dietary supplements, we characterized the silver-containing nanoparticles in 22 commercial products that advertised the use of silver or colloidal silver as the active ingredient. Characterization parameters included: total silver, fractionated silver (particulate and dissolved), primary particle size distribution, hydrodynamic diameter, particle number, and plasmon resonance absorbance. A high degree of variability between claimed and measured values for total silver was observed. Only 7 of the products showed total silver concentrations within 20% of their nominally reported values. In addition, significant variations in the relative percentages of particulate vs. soluble silver were also measured in many of these products reporting to be colloidal. Primary silver particle size distributions by transmission electron microscopy (TEM) showed two populations of particles - smaller particles (<5nm) and larger particles between 20 and 40nm. Hydrodynamic diameter measurements using nanoparticle tracking analysis (NTA) correlated well with TEM analysis for the larger particles. Z-average (Z-Avg) values measured using dynamic light scattering (DLS); however, were typically larger than both NTA or TEM particle diameters. Plasmon resonance absorbance signatures (peak absorbance at around 400nm indicative of metallic silver nanoparticles) were only noted in 4 of the 9 yellow-brown colored suspensions. Although the total silver concentrations were variable among products, ranging from 0.54mg/L to 960mg/L, silver containing nanoparticles were identified in all of the product suspensions by TEM. Published by Elsevier B.V.

  5. Height and weight errors in aeromedical certification data.

    DOT National Transportation Integrated Search

    1973-06-01

    The Framingham Relative Weight Index (FRWI) of obesity was described in previous reports as a screening aid for detecting susceptibility to coronary heart disease (CHD). FRWI calculation requires measured values of height and weight but the height an...

  6. Nutrient Estimation Using Subsurface Sensing Methods

    USDA-ARS?s Scientific Manuscript database

    This report investigates the use of precision management techniques for measuring soil conductivity on feedlot surfaces to estimate nutrient value for crop production. An electromagnetic induction soil conductivity meter was used to collect apparent soil electrical conductivity (ECa) from feedlot p...

  7. Hyperfine structure measurements of neutral iodine atom (127I) using Fourier Transform Spectrometry

    NASA Astrophysics Data System (ADS)

    Ashok, Chilukoti; Vishwakarma, S. R.; Bhatt, Himal; Ankush, B. K.; Deo, M. N.

    2018-01-01

    We report the hyperfine Structure (hfs) splitting observations of neutral iodine atom (II) in the 6000 - 10,000 cm-1 near infrared spectral region. The measurements were carried out using a high-resolution Fourier Transform Spectrometer (FTS), where an electrodeless discharge lamp (EDL), excited using microwaves, was employed as the light source and InGaAs as the light detector. A specially designed setup was used to lower the plasma temperature of the medium so as to reduce the Doppler width and consequently to increase the spectral resolution of hfs components. A total of 183 lines with hfs splitting have been observed, out of which hfs in 53 spectral lines are reported for the first time. On the basis of hfs analysis, we derived the magnetic dipole and electric quadrupole coupling constants, A and B respectively for 30 even and 30 odd energy levels and are compared with the values available in the literature. New hfs values for 5 even and 4 odd levels are also reported here for the first time.

  8. Final report of the key comparison APMP.QM-K9: APMP comparison on pH measurement of phosphate buffer

    NASA Astrophysics Data System (ADS)

    Hioki, Akiharu; Ohata, Masaki; Cherdchu, Chainarong; Tangpaisarnkul, Nongluck

    2011-01-01

    The APMP.QM-K9 was organised by TCQM of APMP to test the abilities of the national metrology institutes in the APMP region to measure a pH value of a phosphate buffer. This APMP comparison on pH measurement was proposed by the National Metrology Institute of Japan, NMIJ, and the National Institute of Metrology of Thailand, NIMT, in August 2009. After approval by TCQM, the comparison has been conducted by NMIJ and NIMT. The comparison is a key comparison following CCQM-K9, CCQM-K9.1 and CCQM-K9.2. The comparison material was a phosphate buffer of pH around 6.86 and the measurement temperatures were 15 °C, 25 °C and 37 °C. This is the first APMP key comparison on pH measurement and the third APMP comparison on pH measurement following APMP.QM-P06 (two phosphate buffers) in 2004 and APMP.QM-P09 (a phthalate buffer) in 2006. The results can be used further by any participant to support its CMC claim for a phosphate buffer. That claim will concern the pH method employed by the participant during this comparison and will cover the temperature(s) used or the full temperature range between 15 °C and 37 °C for the participant which measured pH values at the three temperatures. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  9. Improved efficiency of extraction of polycyclic aromatic hydrocarbons (PAHs) from the National Institute of Standards and Technology (NIST) Standard Reference Material Diesel Particulate Matter (SRM 2975) using accelerated solvent extraction.

    PubMed

    Masala, Silvia; Ahmed, Trifa; Bergvall, Christoffer; Westerholm, Roger

    2011-12-01

    The efficiency of extraction of polycyclic aromatic hydrocarbons (PAHs) with molecular masses of 252, 276, 278, 300, and 302 Da from standard reference material diesel particulate matter (SRM 2975) has been investigated using accelerated solvent extraction (ASE) with dichloromethane, toluene, methanol, and mixtures of toluene and methanol. Extraction of SRM 2975 using toluene/methanol (9:1, v/v) at maximum instrumental settings (200 °C, 20.7 MPa, and five extraction cycles) with 30-min extraction times resulted in the following elevations of the measured concentration when compared with the certified and reference concentrations reported by the National Institute of Standards and Technology (NIST): benzo[b]fluoranthene, 46%; benzo[k]fluoranthene, 137%; benzo[e]pyrene, 103%; benzo[a]pyrene, 1,570%; perylene, 37%; indeno[1,2,3-cd]pyrene, 41%; benzo[ghi]perylene, 163%; and coronene, 361%. The concentrations of the following PAHs were comparable to the reference values assigned by NIST: indeno[1,2,3-cd]fluoranthene, dibenz[a,h]anthracene, and picene. The measured concentration of dibenzo[a,e]-pyrene was lower than the information value reported by the NIST. The measured concentrations of other highly carcinogenic PAHs (dibenzo[a,l]pyrene, dibenzo[a,i]pyrene, and dibenzo[a,h]pyrene) in SRM 2975 are also reported. Comparison of measurements using the optimized ASE method and using similar conditions to those applied by the NIST for the assignment of PAH concentrations in SRM 2975 indicated that the higher values obtained in the present study were associated with more complete extraction of PAHs from the diesel particulate material. Re-extraction of the particulate samples demonstrated that the deuterated internal standards were more readily recovered than the native PAHs, which may explain the lower values reported by the NIST. The analytical results obtained in the study demonstrated that the efficient extraction of PAHs from SRM 2975 is a critical requirement for the accurate determination of PAHs with high molecular masses in this standard reference material and that the optimization of extraction conditions is essential to avoid underestimation of the PAH concentrations. The requirement is especially relevant to the human carcinogen benzo[a]pyrene, which is commonly used as an indicator of the carcinogenic risk presented by PAH mixtures.

  10. Noninvasive measurement of carboxyhemoglobin levels for adjustment of diffusion capacity measured during pulmonary function testing.

    PubMed

    Mahoney, Anne M; Stimpson, Claudia L; Scott, Karen L; Hampson, Neil B

    2007-12-01

    The diffusing capacity of the lungs for carbon monoxide (D(LCO)) is commonly measured during pulmonary function testing (PFT). Although adjustment of the measured D(LCO) for an elevated baseline carboxyhemoglobin level is recommended, carboxyhemoglobin is not routinely measured, which may reduce the accuracy of D(LCO) measurements. We sought to assess the utility of routine carboxyhemoglobin measurement and subsequent D(LCO) correction in patients referred for PFT. We retrospectively reviewed 100 consecutive PFT results, including D(LCO) assessment. We used a pulse CO-oximeter (recently approved by the Food and Drug Administration) to noninvasively measure baseline carboxyhemoglobin (S(pCO)). We used simple descriptive statistics to compare the S(pCO) values. In subjects with elevated S(pCO) (> 2%) we adjusted the percent-of-predicted D(LCO). Interpretation of D(LCO) was categorized according to the American Thoracic Society classification scheme for respiratory impairment. The self-reported smokers had higher average S(pCO) than did self-reported nonsmokers (1.6% vs 3.5%, p < 0.001), although 14% of nonsmokers had an elevated S(pCO) and 26% of smokers had normal S(pCO). When the D(LCO) was corrected for elevated S(pCO), 2 patients moved from a category of moderate impairment to mild impairment. Both were smokers. The noninvasive measurement of carboxyhemoglobin is easy to perform during PFT. When precise measurement of D(LCO) is important, noninvasive measurement of carboxyhemoglobin may be of value. If routine S(pCO) measurement is considered, the highest yield is among current smokers.

  11. A Study on Possibility of Clinical Application for Color Measurements of Shade Guides Using an Intraoral Digital Scanner.

    PubMed

    Yoon, Hyung-In; Bae, Ji-Won; Park, Ji-Man; Chun, Youn-Sic; Kim, Mi-Ae; Kim, Minji

    2016-11-07

    To assess if color measurement with intraoral scanner correlates with digital colorimeter and to evaluate the possibility of application of a digital scanner for shade selection. The L*a*b* values of the five shade tabs (A1, A2, A3, A3.5, and A4) were obtained with an intraoral scanner (TRIOS Pod) and a colorimeter (ShadeEye). Both devices were calibrated according to the manufacturer's instructions before measurements. Color measurement values were compared with paired t-test, and a Pearson's correlation analysis was performed to evaluate the relationship of two methods. The L*a*b* values of the colorimeter were significantly different from those of the digital scanner (p < 0.001). The L* and b* values of both methods were strongly correlated with each other (both p < 0.05). The device repeatability in both methods were reported to be excellent (p < 0.05). Within the limitations of this study, color measurements with digital intraoral scanners and computer-assisted image analysis were in accordance with those of the colorimeter with respect to L* and b* values; however, all the coordinates of shade tabs were significantly different between two methods. The digital intraoral scanner may not be used as the primary method of color selection in clinical practices, considering significant differences in color parameters with colorimeter. The scanner's capability in shade selection should be further evaluated. © 2016 by the American College of Prosthodontists.

  12. Accurate viscosity measurements of flowing aqueous glucose solutions with suspended scatterers using a dynamic light scattering approach with optical coherence tomography.

    PubMed

    Weatherbee, Andrew; Popov, Ivan; Vitkin, Alex

    2017-08-01

    The viscosity of turbid colloidal glucose solutions has been accurately determined from spectral domain optical coherence tomography (OCT) M-mode measurements and our recently developed OCT dynamic light scattering model. Results for various glucose concentrations, flow speeds, and flow angles are reported. The relative "combined standard uncertainty" uc(η) on the viscosity measurements was ±1% for the no-flow case and ±5% for the flow cases, a significant improvement in measurement robustness over previously published reports. The available literature data for the viscosity of pure water and our measurements differ by 1% (stagnant case) and 1.5% (flow cases), demonstrating good accuracy; similar agreement is seen across the measured glucose concentration range when compared to interpolated literature values. The developed technique may contribute toward eventual noninvasive glucose measurements in medicine. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  13. Platinum catalytic effect on oxygen fugacity of CO 2H 2 gas mixtures measured with ZrO 2 oxygen sensor at 105 Pa from 1300 to 700°C

    NASA Astrophysics Data System (ADS)

    Miyamoto, M.; Mikouchi, T.

    1996-08-01

    The oxygen fugacity of CO 2H 2 gas mixtures were measured with a ZrO 2 oxygen sensor at high temperatures in a furnace. We confirmed that the oxygen fugacity values measured by the ZrO 2 cell are more reducing than those of the CO 2H 2 gas mixtures calculated by using JANAF data at temperatures below 1150°C as was previously reported by Huebner (1975). We successfully decreased the deviation of the measured oxygen-fugacity value from the calculated one down to temperature of 800°C by using a Pt catalyst. Our results suggest that the deviation is probably due to incomplete equilibration of the gases.

  14. Quantitative angle-insensitive flow measurement using relative standard deviation OCT.

    PubMed

    Zhu, Jiang; Zhang, Buyun; Qi, Li; Wang, Ling; Yang, Qiang; Zhu, Zhuqing; Huo, Tiancheng; Chen, Zhongping

    2017-10-30

    Incorporating different data processing methods, optical coherence tomography (OCT) has the ability for high-resolution angiography and quantitative flow velocity measurements. However, OCT angiography cannot provide quantitative information of flow velocities, and the velocity measurement based on Doppler OCT requires the determination of Doppler angles, which is a challenge in a complex vascular network. In this study, we report on a relative standard deviation OCT (RSD-OCT) method which provides both vascular network mapping and quantitative information for flow velocities within a wide range of Doppler angles. The RSD values are angle-insensitive within a wide range of angles, and a nearly linear relationship was found between the RSD values and the flow velocities. The RSD-OCT measurement in a rat cortex shows that it can quantify the blood flow velocities as well as map the vascular network in vivo .

  15. Quantitative angle-insensitive flow measurement using relative standard deviation OCT

    NASA Astrophysics Data System (ADS)

    Zhu, Jiang; Zhang, Buyun; Qi, Li; Wang, Ling; Yang, Qiang; Zhu, Zhuqing; Huo, Tiancheng; Chen, Zhongping

    2017-10-01

    Incorporating different data processing methods, optical coherence tomography (OCT) has the ability for high-resolution angiography and quantitative flow velocity measurements. However, OCT angiography cannot provide quantitative information of flow velocities, and the velocity measurement based on Doppler OCT requires the determination of Doppler angles, which is a challenge in a complex vascular network. In this study, we report on a relative standard deviation OCT (RSD-OCT) method which provides both vascular network mapping and quantitative information for flow velocities within a wide range of Doppler angles. The RSD values are angle-insensitive within a wide range of angles, and a nearly linear relationship was found between the RSD values and the flow velocities. The RSD-OCT measurement in a rat cortex shows that it can quantify the blood flow velocities as well as map the vascular network in vivo.

  16. The usefulness of “corrected” body mass index vs. self-reported body mass index: comparing the population distributions, sensitivity, specificity, and predictive utility of three correction equations using Canadian population-based data

    PubMed Central

    2014-01-01

    Background National data on body mass index (BMI), computed from self-reported height and weight, is readily available for many populations including the Canadian population. Because self-reported weight is found to be systematically under-reported, it has been proposed that the bias in self-reported BMI can be corrected using equations derived from data sets which include both self-reported and measured height and weight. Such correction equations have been developed and adopted. We aim to evaluate the usefulness (i.e., distributional similarity; sensitivity and specificity; and predictive utility vis-à-vis disease outcomes) of existing and new correction equations in population-based research. Methods The Canadian Community Health Surveys from 2005 and 2008 include both measured and self-reported values of height and weight, which allows for construction and evaluation of correction equations. We focused on adults age 18–65, and compared three correction equations (two correcting weight only, and one correcting BMI) against self-reported and measured BMI. We first compared population distributions of BMI. Second, we compared the sensitivity and specificity of self-reported BMI and corrected BMI against measured BMI. Third, we compared the self-reported and corrected BMI in terms of association with health outcomes using logistic regression. Results All corrections outperformed self-report when estimating the full BMI distribution; the weight-only correction outperformed the BMI-only correction for females in the 23–28 kg/m2 BMI range. In terms of sensitivity/specificity, when estimating obesity prevalence, corrected values of BMI (from any equation) were superior to self-report. In terms of modelling BMI-disease outcome associations, findings were mixed, with no correction proving consistently superior to self-report. Conclusions If researchers are interested in modelling the full population distribution of BMI, or estimating the prevalence of obesity in a population, then a correction of any kind included in this study is recommended. If the researcher is interested in using BMI as a predictor variable for modelling disease, then both self-reported and corrected BMI result in biased estimates of association. PMID:24885210

  17. Rayleigh scattering measurements of several fluorocarbon gases.

    PubMed

    Zadoo, Serena; Thompson, Jonathan E

    2011-11-01

    Integrating nephelometers are commonly used to monitor airborne particulate matter. However, they must be calibrated prior to use. The Rayleigh scattering coefficients (b(RS), Mm(-1)), scattering cross sections (σ(RS), cm(2)), and Rayleigh multipliers for tetrafluoromethane (R-14), sulfur hexafluoride, pentafluoroethane (HFC-125), hexafluoropropene (HFC-216), 1,1,1,2,3,3,3,-heptafluoropropane (HFC-227ea), and octafluorocyclobutane (C-318) are reported from measurements made using a Radiance Research M903 integrating nephelometer operating at λ = 530 nm and calibration with gases of known scattering constants. Rayleigh multipliers (±90% conf. int.) were found to be 2.6 ± 0.5, 6.60 ± 0.07, 7.5 ± 1, 14.8 ± 0.9, 15.6 ± 0.5, and 22.3 ± 0.8 times that of air, respectively. To the best of our knowledge, these are the first reported values for R-14, HFC-216, HFC-125, and C-318. Experimental accuracy is supported through measurements of values for SF(6) and HFC-227ea which agree to within 3% of previous literature reports. In addition to documenting fundamental Rayleigh scattering data for the first time, the information presented within will find use for calibration of optical scattering sensors such as integrating nephelometers.

  18. Application of speckle dynamics for studying metabolic activity of cell cultures with herpes virus

    NASA Astrophysics Data System (ADS)

    Vladimirov, A. P.; Bakharev, A. A.; Malygin, A. S.; Mikhaylova, J. A.; Borodin, E. M.; Poryvayeva, A. P.; Glinskikh, N. P.

    2014-05-01

    The report considers the results of the experiments in which digital values of light intensity I and the image area correlation index η values were recorded on a real-time basis for one or two days. Three cell cultures with viruses along with intact cultures were investigated. High correlation of dependence of η values on time t values was demonstrated for three cultures. The η=η(t) and I=I(t) dependences for cells with and without viruses differ considerably. It was shown that the presence of viruses could be determined as early as ten minutes after measurements were started.

  19. Hydraulic fracturing stress measurement in underground salt rock mines at Upper Kama Deposit

    NASA Astrophysics Data System (ADS)

    Rubtsova, EV; Skulkin, AA

    2018-03-01

    The paper reports the experimental results on hydraulic fracturing in-situ stress measurements in potash mines of Uralkali. The selected HF procedure, as well as locations and designs of measuring points are substantiated. From the evidence of 78 HF stress measurement tests at eight measuring points, it has been found that the in-situ stress field is nonequicomponent, with the vertical stresses having value close to the estimates obtained with respect to the overlying rock weight while the horizontal stresses exceed the gravity stresses by 2–3 times.

  20. The Muon g-2 experiment at Fermilab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chapelain, Antoine

    The upcoming Fermilab E989 experiment will measure the muon anomalous magnetic moment aμ. This measurement is motivated by the previous measurement performed in 2001 by the BNL E821 experiment that reported a 3-4 standard deviation discrepancy between the measured value and the Standard Model prediction. The new measurement at Fermilab aims to improve the precision by a factor of four reducing the total uncertainty from 540 parts per billion (BNL E821) to 140 parts per billion (Fermilab E989). This paper gives the status of the experiment.

  1. The Muon g-2 experiment at Fermilab

    NASA Astrophysics Data System (ADS)

    Chapelain, Antoine

    2017-03-01

    The upcoming Fermilab E989 experiment will measure the muon anomalous magnetic moment aμ. This measurement is motivated by the previous measurement performed in 2001 by the BNL E821 experiment that reported a 3-4 standard deviation discrepancy between the measured value and the Standard Model prediction. The new measurement at Fermilab aims to improve the precision by a factor of four reducing the total uncertainty from 540 parts per billion (BNL E821) to 140 parts per billion (Fermilab E989). This paper gives the status of the experiment.

  2. Prognostic value of quantitative sensory testing in low back pain: a systematic review of the literature

    PubMed Central

    Marcuzzi, Anna; Dean, Catherine M; Wrigley, Paul J; Chakiath, Rosemary J; Hush, Julia M

    2016-01-01

    Quantitative sensory testing (QST) measures have recently been shown to predict outcomes in various musculoskeletal and pain conditions. The aim of this systematic review was to summarize the emerging body of evidence investigating the prognostic value of QST measures in people with low back pain (LBP). The protocol for this review was prospectively registered on the International Prospective Register of Systematic Reviews. An electronic search of six databases was conducted from inception to October 2015. Experts in the field were contacted to retrieve additional unpublished data. Studies were included if they were prospective longitudinal in design, assessed at least one QST measure in people with LBP, assessed LBP status at follow-up, and reported the association of QST data with LBP status at follow-up. Statistical pooling of results was not possible due to heterogeneity between studies. Of 6,408 references screened after duplicates removed, three studies were finally included. None of them reported a significant association between the QST measures assessed and the LBP outcome. Three areas at high risk of bias were identified which potentially compromise the validity of these results. Due to the paucity of available studies and the methodological shortcomings identified, it remains unknown whether QST measures are predictive of outcome in LBP. PMID:27660486

  3. Prognostic value of quantitative sensory testing in low back pain: a systematic review of the literature.

    PubMed

    Marcuzzi, Anna; Dean, Catherine M; Wrigley, Paul J; Chakiath, Rosemary J; Hush, Julia M

    2016-01-01

    Quantitative sensory testing (QST) measures have recently been shown to predict outcomes in various musculoskeletal and pain conditions. The aim of this systematic review was to summarize the emerging body of evidence investigating the prognostic value of QST measures in people with low back pain (LBP). The protocol for this review was prospectively registered on the International Prospective Register of Systematic Reviews. An electronic search of six databases was conducted from inception to October 2015. Experts in the field were contacted to retrieve additional unpublished data. Studies were included if they were prospective longitudinal in design, assessed at least one QST measure in people with LBP, assessed LBP status at follow-up, and reported the association of QST data with LBP status at follow-up. Statistical pooling of results was not possible due to heterogeneity between studies. Of 6,408 references screened after duplicates removed, three studies were finally included. None of them reported a significant association between the QST measures assessed and the LBP outcome. Three areas at high risk of bias were identified which potentially compromise the validity of these results. Due to the paucity of available studies and the methodological shortcomings identified, it remains unknown whether QST measures are predictive of outcome in LBP.

  4. Nasal Morphology of the Chinese: Three-Dimensional Reference Values for Rhinoplasty.

    PubMed

    Jayaratne, Yasas S N; Deutsch, Curtis K; Zwahlen, Roger A

    2014-06-01

    To determine normative nasal measurements for Chinese young adults, conditioned on demographics. A cross-sectional descriptive study. A university hospital. Three-dimensional (3D) photographs were captured from 103 Chinese subjects between 18 and 35 years of age using a commercial stereophotographic system. Anthropometric landmarks were identified on these 3D surface images, and measurements suitable for nasal analysis were performed and contrasted against established Caucasian norms. Gender differences in anthropometric dimensions were also analyzed. Normative data for these measurements are made available. Linear nasal measurements, except those for mid-columella length, were significantly larger in men than in women; further, the nasal tip angle and nasofrontal angle were significantly larger in Chinese women. Contrasts of these new data against published Caucasian norms revealed dimensions that differ for these 2 groups. The Chinese normative mean values for morphological nose width, nasal tip angle, nasofrontal angle, and alar slope angle exceeded those reported for North American Caucasians. Gender-specific normative data for the Chinese nose were established in this study to provide a useful tool for surgeons in dealing with rhinoplasty. Moreover, the Chinese nasal anthropometric measurements in this study are broader and flatter than those reported for North American Caucasians. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.

  5. Cultural influences on positive father involvement in two-parent Mexican-origin families.

    PubMed

    Cruz, Rick A; King, Kevin M; Widaman, Keith F; Leu, Janxin; Cauce, Ana Mari; Conger, Rand D

    2011-10-01

    A growing body of research documents the importance of positive father involvement in children's development. However, research on fathers in Latino families is sparse, and research contextualizing the father-child relationship within a cultural framework is needed. The present study examined how fathers' cultural practices and values predicted their fifth-grade children's report of positive father involvement in a sample of 450 two-parent Mexican-origin families. Predictors included Spanish- and English-language use, Mexican and American cultural values, and positive machismo (i.e., culturally related attitudes about the father's role within the family). Positive father involvement was measured by the child's report of his or her father's monitoring, educational involvement, and warmth. Latent variable regression analyses showed that fathers' machismo attitudes were positively related to children's report of positive father involvement and that this association was similar across boys and girls. The results of this study suggest an important association between fathers' cultural values about men's roles and responsibilities within a family and their children's perception of positive fathering.

  6. Solid-state dosimeters: A new approach for mammography measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brateman, Libby F., E-mail: bratel@radiology.ufl.edu; Heintz, Philip H.

    2015-02-15

    Purpose: To compare responses of modern commercially available solid-state dosimeters (SStDs) used in mammography medical physics surveys for two major vendors of current digital mammography units. To compare differences in dose estimates among SStD responses with ionization chamber (IC) measurements for several target/filter (TF) combinations and report their characteristics. To review scientific bases for measurements of quantities required for mammography for traditional measurement procedures and SStDs. Methods: SStDs designed for use with modern digital mammography units were acquired for evaluation from four manufacturers. Each instrument was evaluated under similar conditions with the available mammography beams provided by two modern full-fieldmore » digital mammography units in clinical use: a GE Healthcare Senographe Essential (Essential) and a Hologic Selenia Dimensions 5000 (Dimensions), with TFs of Mo/Mo, Mo/Rh; and Rh/Rh and W/Rh, W/Ag, and W/Al, respectively. Measurements were compared among the instruments for the TFs over their respective clinical ranges of peak tube potentials for kVp and half-value layer (HVL) measurements. Comparisons for air kerma (AK) and their associated relative calculated average glandular doses (AGDs), i.e., using fixed mAs, were evaluated over the limited range of 28–30 kVp. Measurements were compared with reference IC measurements for AK, reference HVLs and calculated AGD, for two compression paddle heights for AK, to evaluate scatter effects from compression paddles. SStDs may require different positioning from current mammography measurement protocols. Results: Measurements of kVp were accurate in general for the SStDs (within −1.2 and +1.1 kVp) for all instruments over a wide range of set kVp’s and TFs and most accurate for Mo/Mo and W/Rh. Discrepancies between measurements and reference values were greater for HVL and AK. Measured HVL values differed from reference values by −6.5% to +3.5% depending on the SStD and TF. AK measurements over limited (28–30) kVp’s ranged from −6% to +7% for SStDs, compared with IC reference values. Relative AGDs for each SStD using its associated measurements of kVp, HVL and AK underestimated AGD in nearly all cases, compared with reference IC values, with discrepancies of <−1% to ∼−10%. Some differences in AGD were related to differences in contributions of compression paddle scatter to AK measurements made by ICs. Applying measured factors for scatter effects in AK measurements for three SStDs reduced discrepancies between −6.2% and +1.3%, shifting AGDs from SStDs closer to IC AGDs. Conclusions: This study revealed that SStD measurements yielded good agreement with set kVp, poor agreement with standard HVL determinations, and AK measurements that were substantially different from IC measurements. Discrepancies are partly related to the scattered radiation measured by ICs in determining AK. As a result, IC measurements required for AGD, using currently accepted methodology, typically result in higher AGDs than SStDs, because current methodologies do not account for differing instrument responses to scatter. HVLs reported by SStDs contribute to discrepancies in calculated AGD that depend on kVp and TF. Medical physicists are encouraged to compare their results for SStD instruments using a similar methodology for potential discrepancies with their traditional instruments.« less

  7. Who receives a medical evaluation for infertility in the United States?

    PubMed Central

    Farland, Leslie V; Collier, Ai-ris Y; Correia, Katharine F; Grodstein, Francine; Chavarro, Jorge E; Rich-Edwards, Janet; Missmer, Stacey A

    2015-01-01

    Objective To investigate characteristics of receiving a medical evaluation for infertility among infertile women Design Prospective Cohort Setting Academic Institution Patients Seven thousand four-hundred and twenty two women who reported incident infertility between 1989 and 2009 in the Nurses’ Health Study II. Intervention None Main Outcome Measures Report of receiving a medical evaluation for infertility Results Approximately 65% of women who reported infertility had a medical evaluation for infertility. Infertile women who were parous (RR:0.81, CI:0.78, 0.84), older (P-value, test for linear trend:<0.001), current smokers (RR:0.89, CI:0.83, 0.96), or who had a higher body mass index (BMI)(P-value: 0.01) were less likely to report receiving a medical infertility evaluation. Infertile women who exercised frequently (P-value: 0.04), took multivitamins (RR: 1.03, CI:1.00, 1.07), lived in states with comprehensive insurance coverage (RR:1.09, CI:1.00, 1.19), had a high household income (P-value: 0.05), or who had a recent physical exam (RR:1.15, CI:1.06, 1.24) were more likely to report receiving a medical infertility evaluation. Conclusions These findings highlight demographic, lifestyle, and access barriers to receiving medical infertility care. Historically, the discussion of barriers to infertility care has centered on financial access, geographic access, and socioeconomic status. Our findings build off previous literature by supporting previously reported associations and showcasing the importance of demographic and lifestyle factors in accessing care. PMID:26785253

  8. Evaluation of Low-Cost Mitigation Measures Implemented to Improve Air Quality in Nursery and Primary Schools

    PubMed Central

    Sá, Juliana P.; Branco, Pedro T. B. S.; Alvim-Ferraz, Maria C. M.; Martins, Fernando G.; Sousa, Sofia I. V.

    2017-01-01

    Indoor air pollution mitigation measures are highly important due to the associated health impacts, especially on children, a risk group that spends significant time indoors. Thus, the main goal of the work here reported was the evaluation of mitigation measures implemented in nursery and primary schools to improve air quality. Continuous measurements of CO2, CO, NO2, O3, CH2O, total volatile organic compounds (VOC), PM1, PM2.5, PM10, Total Suspended Particles (TSP) and radon, as well as temperature and relative humidity were performed in two campaigns, before and after the implementation of low-cost mitigation measures. Evaluation of those mitigation measures was performed through the comparison of the concentrations measured in both campaigns. Exceedances to the values set by the national legislation and World Health Organization (WHO) were found for PM2.5, PM10, CO2 and CH2O during both indoor air quality campaigns. Temperature and relative humidity values were also above the ranges recommended by American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). In general, pollutant concentrations measured after the implementation of low-cost mitigation measures were significantly lower, mainly for CO2. However, mitigation measures were not always sufficient to decrease the pollutants’ concentrations till values considered safe to protect human health. PMID:28561795

  9. Perfusion in Rat Brain at 7 T with Arterial Spin Labeling Using FAIR-TrueFISP and QUIPSS

    PubMed Central

    Esparza-Coss, Emilio; Wosik, Jarek; Narayana, Ponnada A.

    2010-01-01

    Measurement of perfusion in longitudinal studies allows for the assessment of tissue integrity and the detection of subtle pathologies. In this work, the feasibility of measuring brain perfusion in rats with high spatial resolution using arterial spin labeling (ASL) is reported. A flow sensitive alternating recovery (FAIR) sequence, coupled with a balanced gradient fast imaging with steady state precession (TrueFISP) readout section was used to minimize ghosting and geometric distortions, while achieving high SNR. The quantitative imaging of perfusion using a single subtraction (QUIPSS) method was implemented to address the effects of variable transit delays between the labeling of spins and their arrival at the imaging slice. Studies in six rats at 7 T showed good perfusion contrast with minimal geometric distortion. The measured blood flow values of 152.5 ± 6.3 ml/100g/min in gray matter and 72.3 ± 14.0 ml/100g/min in white matter are in good agreement with previously reported values based on autoradiography, considered to be the gold standard. PMID:20299174

  10. Theoretical Analysis of Optical Absorption and Emission in Mixed Noble Metal Nanoclusters.

    PubMed

    Day, Paul N; Pachter, Ruth; Nguyen, Kiet A

    2018-04-26

    In this work, we studied theoretically two hybrid gold-silver clusters, which were reported to have dual-band emission, using density functional theory (DFT) and linear and quadratic response time-dependent DFT (TDDFT). Hybrid functionals were found to successfully predict absorption and emission, although explanation of the NIR emission from the larger cluster (cluster 1) requires significant vibrational excitation in the final state. For the smaller cluster (cluster 2), the Δ H(0-0) value calculated for the T1 → S0 transition, using the PBE0 functional, is in good agreement with the measured NIR emission, and the calculated T2 → S0 value is in fair agreement with the measured visible emission. The calculated T1 → S0 phosphorescence Δ H(0-0) for cluster 1 is close to the measured visible emission energy. In order for the calculated phosphorescence for cluster 1 to agree with the intense NIR emission reported experimentally, the vibrational energy of the final state (S0) is required to be about 0.7 eV greater than the zero-point vibrational energy.

  11. Radiative data for highly excited 3d84d levels in Ni II from laboratory measurements and atomic calculations

    NASA Astrophysics Data System (ADS)

    Hartman, H.; Engström, L.; Lundberg, H.; Nilsson, H.; Quinet, P.; Fivet, V.; Palmeri, P.; Malcheva, G.; Blagoev, K.

    2017-04-01

    Aims: This work reports new experimental radiative lifetimes and calculated oscillator strengths for transitions from 3d84d levels of astrophysical interest in singly ionized nickel. Methods: Radiative lifetimes of seven high-lying levels of even parity in Ni II (98 400-100 600 cm-1) have been measured using the time-resolved laser-induced fluorescence method. Two-step photon excitation of ions produced by laser ablation has been utilized to populate the levels. Theoretical calculations of the radiative lifetimes of the measured levels and transition probabilities from these levels are reported. The calculations have been performed using a pseudo-relativistic Hartree-Fock method, taking into account core polarization effects. Results: A new set of transition probabilities and oscillator strengths has been deduced for 477 Ni II transitions of astrophysical interest in the spectral range 194-520 nm depopulating even parity 3d84d levels. The new calculated gf-values are, on the average, about 20% higher than a previous calculation and yield lifetimes within 5% of the experimental values.

  12. Measurement of the proton-air cross section with Telescope Array's Middle Drum detector and surface array in hybrid mode

    NASA Astrophysics Data System (ADS)

    Abbasi, R. U.; Abe, M.; Abu-Zayyad, T.; Allen, M.; Azuma, R.; Barcikowski, E.; Belz, J. W.; Bergman, D. R.; Blake, S. A.; Cady, R.; Chae, M. J.; Cheon, B. G.; Chiba, J.; Chikawa, M.; Cho, W. R.; Fujii, T.; Fukushima, M.; Goto, T.; Hanlon, W.; Hayashi, Y.; Hayashida, N.; Hibino, K.; Honda, K.; Ikeda, D.; Inoue, N.; Ishii, T.; Ishimori, R.; Ito, H.; Ivanov, D.; Jui, C. C. H.; Kadota, K.; Kakimoto, F.; Kalashev, O.; Kasahara, K.; Kawai, H.; Kawakami, S.; Kawana, S.; Kawata, K.; Kido, E.; Kim, H. B.; Kim, J. H.; Kim, J. H.; Kitamura, S.; Kitamura, Y.; Kuzmin, V.; Kwon, Y. J.; Lan, J.; Lim, S. I.; Lundquist, J. P.; Machida, K.; Martens, K.; Matsuda, T.; Matsuyama, T.; Matthews, J. N.; Minamino, M.; Mukai, Y.; Myers, I.; Nagasawa, K.; Nagataki, S.; Nakamura, T.; Nonaka, T.; Nozato, A.; Ogio, S.; Ogura, J.; Ohnishi, M.; Ohoka, H.; Oki, K.; Okuda, T.; Ono, M.; Oshima, A.; Ozawa, S.; Park, I. H.; Pshirkov, M. S.; Rodriguez, D. C.; Rubtsov, G.; Ryu, D.; Sagawa, H.; Sakurai, N.; Scott, L. M.; Shah, P. D.; Shibata, F.; Shibata, T.; Shimodaira, H.; Shin, B. K.; Shin, H. S.; Smith, J. D.; Sokolsky, P.; Springer, R. W.; Stokes, B. T.; Stratton, S. R.; Stroman, T. A.; Suzawa, T.; Takamura, M.; Takeda, M.; Takeishi, R.; Taketa, A.; Takita, M.; Tameda, Y.; Tanaka, H.; Tanaka, K.; Tanaka, M.; Thomas, S. B.; Thomson, G. B.; Tinyakov, P.; Tkachev, I.; Tokuno, H.; Tomida, T.; Troitsky, S.; Tsunesada, Y.; Tsutsumi, K.; Uchihori, Y.; Udo, S.; Urban, F.; Vasiloff, G.; Wong, T.; Yamane, R.; Yamaoka, H.; Yamazaki, K.; Yang, J.; Yashiro, K.; Yoneda, Y.; Yoshida, S.; Yoshii, H.; Zollinger, R.; Zundel, Z.; Telescope Array Collaboration

    2015-08-01

    In this work we are reporting on the measurement of the proton-air inelastic cross section σp-air inel using the Telescope Array detector. Based on the measurement of the σp-air inel, the proton-proton cross section σp -p value is also determined at √{s }=9 5-8+5 TeV . Detecting cosmic ray events at ultrahigh energies with the Telescope Array enables us to study this fundamental parameter that we are otherwise unable to access with particle accelerators. The data used in this report are the hybrid events observed by the Middle Drum fluorescence detector together with the surface array detector collected over five years. The value of the σp-air inel is found to be equal to 567.0 ±70.5 [Stat]-25+29[Sys] mb . The total proton-proton cross section is subsequently inferred from Glauber formalism and the Block, Halzen and Stanev QCD inspired fit and is found to be equal to 17 0-44+48[Stat]-17+19[Sys] mb .

  13. Basic data for some recent Australian heat-flow measurements

    USGS Publications Warehouse

    Munroe, Robert J.; Sass, J.H.; Milburn, G.T.; Jaeger, J.C.; Tammemagi, H.Y.

    1975-01-01

    This report has been compiled to provide background information and detailed temperature and thermal conductivity data for the heat-flow values reported in Sass, Jaeger, and Munroe (in press). The data were collected as part of a joint heat-flow study by the Australian National University (ANU) and the U.S. Geological Survey (USGS) under the direction of J. C. Jaeger (ANU) and J. H. Sass (USGS). The format is similar to that used for basic data from United States heat-flow determinations (Sass and Munroe, 1974). Each section contains a state map showing the geographic distribution of heat-flow data followed by tables which list individual temperatures, thermal conductivities, and radiogenic heat production values. A companion volume (Bunker and others, 1975) gives details of the heat-production measurements together with individual radioelement concentrations. Localities are arranged in alphabetical order within each state. The methods and techniques of measurements have been described by Sass and others (1971a, b). Unusual methods or procedures which differ markedly from these techniques are noted and described in the comments sections of the tables.

  14. Thermo-Osmotic Flow in Thin Films.

    PubMed

    Bregulla, Andreas P; Würger, Alois; Günther, Katrin; Mertig, Michael; Cichos, Frank

    2016-05-06

    We report on the first microscale observation of the velocity field imposed by a nonuniform heat content along the solid-liquid boundary. We determine both radial and vertical velocity components of this thermo-osmotic flow field by tracking single tracer nanoparticles. The measured flow profiles are compared to an approximate analytical theory and to numerical calculations. From the measured slip velocity we deduce the thermo-osmotic coefficient for both bare glass and Pluronic F-127 covered surfaces. The value for Pluronic F-127 agrees well with Soret data for polyethylene glycol, whereas that for glass differs from literature values and indicates the complex boundary layer thermodynamics of glass-water interfaces.

  15. COBE satellite measurement, hyperspheres, superstrings and the dimension of spacetime.

    NASA Astrophysics Data System (ADS)

    El Naschie, M. S.

    1998-08-01

    The first part of the paper attempts to establish connections between hypersphere backing in infinite dimensions, the expectation value of dimE(∞) spacetime and the COBE measurement of the microwave background radiation. One of the main results reported here is that the mean sphere in S(∞) spans a four dimensional manifold and is thus equal to the expectation value of the topological dimension of E(∞). In the second part the author introduces within a general theory, a probabilistic justification for a compactification which reduces an infinite dimensional spacetime E(∞) (n = ∞) to a four dimensional one (DT = n = 4).

  16. AN ASSESSMENT OF CULTURAL VALUES AND RESIDENT-CENTERED CULTURE CHANGE IN US NURSING FACILITIES

    PubMed Central

    Banaszak-Holl, Jane; Castle, Nicholas G.; Lin, Michael; Spreitzer, Gretchen

    2012-01-01

    Background Culture Change initiatives propose to improve care by addressing the lack of managerial supports and prevalent stressful work environments in the industry; however, little is known about how Culture Change facilities differ from facilities in the industry that have not chosen to affiliate with the resident-centered care movements. Purpose To evaluate representation of organizational culture values within a random sample of U.S. nursing home facilities using the Competing Values Framework (CVF) and to determine whether organizational values are related to membership in resident-centered Culture Change initiatives. Design and Methods We collected reports of cultural values using a well-established CVF instrument in a random survey of facility administrators and directors of nursing within all states. We received responses from 57% of the facilities that were mailed the survey. Directors of nursing and administrators did not vary significantly in their reports of culture and facility measures combine their responses. Findings Nursing facilities favored market-focused cultural values on average and developmental values, key to innovation, were the least common across all nursing homes. Approximately 17% of facilities reported all cultural values were strong within their facilities. Only high developmental cultural values were linked to participation in culture change initiatives. Culture Change facilities were not different from non-Culture Change facilities in the promotion of employee focus as organizational culture, as is emphasized in group culture values. Likewise, Culture Change facilities were also not any more likely to have hierarchical or market foci than non-Culture Change facilities. Practice Implications Our results counter the argument that Culture Change facilities have a stronger internal employee focus than facilities more generally but does show that Culture Change facilities report stronger developmental cultures than non-Culture Change facilities, which indicates a potential to be innovative in their strategies. Facilities are culturally ready to become resident-centered and may face other barriers to adopting these practices. PMID:22936002

  17. Nuclear DNA C‐values in 30 Species Double the Familial Representation in Pteridophytes

    PubMed Central

    OBERMAYER, RENATE; LEITCH, ILIA J.; HANSON, LYNDA; BENNETT, MICHAEL D.

    2002-01-01

    Nuclear DNA C‐values and genome size are important biodiversity characters with fundamental biological significance. Yet C‐value data for pteridophytes, a diverse group of vascular plants with approx. 9000 extant species, remain scarce. A recent survey by Bennett and Leitch (2001, Annals of Botany 87: 335–345) found that C‐values were reported for only 48 pteridophyte species. To improve phylogenetic representation in this group and to check previously reported estimates, C‐values for 30 taxa in 17 families were measured using flow cytometry for all but one species. This technique proved generally applicable, but the ease with which C‐value data were generated varied greatly between materials. Comparing the new data with those previously published revealed several large discrepancies. After discounting doubtful data, C‐values for 62 pteridophyte species remained acceptable for analysis. The present work has increased the number of such species’ C‐values by 93 %, and more than doubled the number of families represented (from 10 to 21). Analysis shows that pteridophyte C‐values vary approx. 450‐fold, from 0·16 pg in Selaginella kraussiana to 72·7 pg in Psilotum nudum var. gasa. Superimposing C‐value data onto a robust phylogeny of pteridophytes suggests some possible trends in C‐value evolution and highlights areas for future work. PMID:12197518

  18. Integrating content and structure aspects of the self: traits, values, and self-improvement.

    PubMed

    Roccas, Sonia; Sagiv, Lilach; Oppenheim, Shani; Elster, Andrey; Gal, Avigail

    2014-04-01

    Research on the structure of the self has mostly developed separately from research on its content. Taking an integrative approach, we studied two structural aspects of the self associated with self-improvement--self-discrepancies and perceived mutability--by focusing on two content areas, traits and values. In Studies 1A-C, 337 students (61% female) reported self-discrepancies in values and traits, with the finding that self-discrepancies in values are smaller than in traits. In Study 2 (80 students, 41% female), we experimentally induced either high or low mutability and measured perceived mutability of traits and values. We found that values are perceived as less mutable than traits. In Study 3, 99 high school students (60% female) reported their values, traits, and the extent to which they wish to change them. We found that values predict the wish to change traits, whereas traits do not predict the wish to change values. In Study 4, 172 students (47.7% female) were assigned to one of four experimental conditions in which they received feedback denoting either uniqueness or similarity to others, on either their values or their traits. The results indicated that feedback that one's values (but not traits) are unique affected self-esteem. Integrating between theories of content and structure of the self can contribute to the development of both. © 2013 Wiley Periodicals, Inc.

  19. A new NIST primary standardization of 18F.

    PubMed

    Fitzgerald, R; Zimmerman, B E; Bergeron, D E; Cessna, J C; Pibida, L; Moreira, D S

    2014-02-01

    A new primary standardization of (18)F by NIST is reported. The standard is based on live-timed beta-gamma anticoincidence counting with confirmatory measurements by three other methods: (i) liquid scintillation (LS) counting using CIEMAT/NIST (3)H efficiency tracing; (ii) triple-to-double coincidence ratio (TDCR) counting; and (iii) NaI integral counting and HPGe γ-ray spectrometry. The results are reported as calibration factors for NIST-maintained ionization chambers (including some "dose calibrators"). The LS-based methods reveal evidence for cocktail instability for one LS cocktail. Using an ionization chamber to link this work with previous NIST results, the new value differs from the previous reports by about 4%, but appears to be in good agreement with the key comparison reference value (KCRV) of 2005. © 2013 Published by Elsevier Ltd.

  20. Comparison of measured and self-reported anthropometric information among firefighters: implications and applications

    PubMed Central

    Hsiao, Hongwei; Weaver, Darlene; Hsiao, James; Whitestone, Jennifer; Kau, Tsui-Ying; Whisler, Richard; Ferri, Robert

    2016-01-01

    This study evaluated the accuracy of self-reported body weight and height compared to measured values among firefighters and identified factors associated with reporting error. A total of 863 male and 88 female firefighters in four US regions participated in the study. The results showed that both men and women underestimated their body weight (−0.4 ± 4.1, −1.1 ± 3.6 kg) and overestimated their height (29 ± 18, 17 ± 16 mm). Women underestimated more than men on weight (p = 0.022) and men overestimated more than women on height (p < 0.001). Reporting errors on weight were increased with overweight status (p < 0.001) and were disproportionate among subgroups. About 27% men and 24% women had reporting errors on weight greater than ± 2.2 kg, and 59% men and 28% women had reporting errors on height greater than 25 mm. PMID:25198061

Top