Science.gov

Sample records for measurement system sistema

  1. Systems Engineering Measurement Primer

    DTIC Science & Technology

    1998-03-01

    Systems Engineering Measurement Primer A Basic Introduction to Systems Engineering Measurement Concepts and Use Version 1.0 March 1998 This document...Federal Systems Garry Roedler Lockheed Martin Management & Data Systems Cathy Tilton The National Registry, Inc. E. Richard Widmann Raytheon Systems...IV 1. INTRODUCTION

  2. Frequency domain measurement systems

    NASA Technical Reports Server (NTRS)

    Eischer, M. C.

    1978-01-01

    Stable frequency sources and signal processing blocks were characterized by their noise spectra, both discrete and random, in the frequency domain. Conventional measures are outlined, and systems for performing the measurements are described. Broad coverage of system configurations which were found useful is given. Their functioning and areas of application are discussed briefly. Particular attention is given to some of the potential error sources in the measurement procedures, system configurations, double-balanced-mixer-phase-detectors, and application of measuring instruments.

  3. Systemic risk measures

    NASA Astrophysics Data System (ADS)

    Guerra, Solange Maria; Silva, Thiago Christiano; Tabak, Benjamin Miranda; de Souza Penaloza, Rodrigo Andrés; de Castro Miranda, Rodrigo César

    2016-01-01

    In this paper we present systemic risk measures based on contingent claims approach and banking sector multivariate density. We also apply network measures to analyze bank common risk exposure. The proposed measures aim to capture credit risk stress and its potential to become systemic. These indicators capture not only individual bank vulnerability, but also the stress dependency structure between them. Furthermore, these measures can be quite useful for identifying systemically important banks. The empirical results show that these indicators capture with considerable fidelity the moments of increasing systemic risk in the Brazilian banking sector in recent years.

  4. Space Acceleration Measurement Systems

    NASA Technical Reports Server (NTRS)

    Foster, William

    2000-01-01

    The Space Acceleration Measurement Systems (SAMS) Project develops and deploys the measurement systems for the Acceleration Measurement Program (AMP). At this time there are two types of measurement systems available, quasi-steady and vibratory. Orbital Acceleration Research Experiment (OARE) and Microgravity Acceleration Measurement System (MAMS) are the current quasi-steady systems available. OARE has flown numerous times supporting STS missions. MAMS has been delivered to Kennedy Space Center (KSC) for its deployment on the International Space Station (ISS). Vibratory measurements have been made and will be made by the Space Acceleration Measurement System (SAMS-I) Generation I, Space Acceleration Measurement System Generation II (SAMS-II), and Space Acceleration Measurement System Free Flyer or Generation III (SAMS-FF). SAMS-I supported 21 STS missions and has been retired. SAMS-II will be delivered to KSC to support ISS-6A launch (currently April 19, 2001). SAMS-FF has replaced SAMS-I in support of STS missions and has been deployed on sounding rockets, the KC-135 and ground facilities. SAMS-FF hardware shall be deployed on ISS in the future to provide a more compact solution.

  5. Precision volume measurement system.

    SciTech Connect

    Fischer, Erin E.; Shugard, Andrew D.

    2004-11-01

    A new precision volume measurement system based on a Kansas City Plant (KCP) design was built to support the volume measurement needs of the Gas Transfer Systems (GTS) department at Sandia National Labs (SNL) in California. An engineering study was undertaken to verify or refute KCP's claims of 0.5% accuracy. The study assesses the accuracy and precision of the system. The system uses the ideal gas law and precise pressure measurements (of low-pressure helium) in a temperature and computer controlled environment to ratio a known volume to an unknown volume.

  6. Optical measurement systems

    NASA Technical Reports Server (NTRS)

    Lesco, Daniel J.

    1987-01-01

    Some of the areas of research conducted at Lewis on optical measurement techniques are described. Two laser anemometer systems developed at Lewis are used to illustrate the special instrumentation needs encountered in aeropropulsion research. Velocity measurements to be made through small viewing ports, close to surfaces within the propulsion system components, and in turbulent or highly-accelerating flows are some of the significant challenges. The application to research facilities of two advanced optical systems, the rainbow schlieren and the combustor viewing system, is presented. The calibration and verification of commercial optical measuring systems, such as droplet sizing systems, are also discussed. Calibration techniques capable of simulating moving droplets for flight-type sizing systems are being developed at Lewis. The presentation concludes with a brief look at the forces driving future research on optical instrumentation.

  7. Ultrasonic linear measurement system

    NASA Technical Reports Server (NTRS)

    Marshall, Scot H. (Inventor)

    1991-01-01

    An ultrasonic linear measurement system uses the travel time of surface waves along the perimeter of a three-dimensional curvilinear body to determine the perimeter of the curvilinear body. The system can also be used piece-wise to measure distances along plane surfaces. The system can be used to measure perimeters where use of laser light, optical means or steel tape would be extremely difficult, time consuming or impossible. It can also be used to determine discontinuities in surfaces of known perimeter or dimension.

  8. Pressure Measurement Systems

    NASA Technical Reports Server (NTRS)

    1990-01-01

    System 8400 is an advanced system for measurement of gas and liquid pressure, along with a variety of other parameters, including voltage, frequency and digital inputs. System 8400 offers exceptionally high speed data acquisition through parallel processing, and its modular design allows expansion from a relatively inexpensive entry level system by the addition of modular Input Units that can be installed or removed in minutes. Douglas Juanarena was on the team of engineers that developed a new technology known as ESP (electronically scanned pressure). The Langley ESP measurement system was based on miniature integrated circuit pressure-sensing transducers that communicated pressure information to a minicomputer. In 1977, Juanarena formed PSI to exploit the NASA technology. In 1978 he left Langley, obtained a NASA license for the technology, introduced the first commercial product, the 780B pressure measurement system. PSI developed a pressure scanner for automation of industrial processes. Now in its second design generation, the DPT-6400 is capable of making 2,000 measurements a second and has 64 channels by addition of slave units. New system 8400 represents PSI's bid to further exploit the $600 million U.S. industrial pressure measurement market. It is geared to provide a turnkey solution to physical measurement.

  9. Pressure Measurement Systems

    NASA Astrophysics Data System (ADS)

    1990-01-01

    System 8400 is an advanced system for measurement of gas and liquid pressure, along with a variety of other parameters, including voltage, frequency and digital inputs. System 8400 offers exceptionally high speed data acquisition through parallel processing, and its modular design allows expansion from a relatively inexpensive entry level system by the addition of modular Input Units that can be installed or removed in minutes. Douglas Juanarena was on the team of engineers that developed a new technology known as ESP (electronically scanned pressure). The Langley ESP measurement system was based on miniature integrated circuit pressure-sensing transducers that communicated pressure information to a minicomputer. In 1977, Juanarena formed PSI to exploit the NASA technology. In 1978 he left Langley, obtained a NASA license for the technology, introduced the first commercial product, the 780B pressure measurement system. PSI developed a pressure scanner for automation of industrial processes. Now in its second design generation, the DPT-6400 is capable of making 2,000 measurements a second and has 64 channels by addition of slave units. New system 8400 represents PSI's bid to further exploit the 600 million U.S. industrial pressure measurement market. It is geared to provide a turnkey solution to physical measurement.

  10. Electrochemical thermodynamic measurement system

    DOEpatents

    Reynier, Yvan; Yazami, Rachid; Fultz, Brent T.

    2009-09-29

    The present invention provides systems and methods for accurately characterizing thermodynamic and materials properties of electrodes and electrochemical energy storage and conversion systems. Systems and methods of the present invention are configured for simultaneously collecting a suite of measurements characterizing a plurality of interconnected electrochemical and thermodynamic parameters relating to the electrode reaction state of advancement, voltage and temperature. Enhanced sensitivity provided by the present methods and systems combined with measurement conditions that reflect thermodynamically stabilized electrode conditions allow very accurate measurement of thermodynamic parameters, including state functions such as the Gibbs free energy, enthalpy and entropy of electrode/electrochemical cell reactions, that enable prediction of important performance attributes of electrode materials and electrochemical systems, such as the energy, power density, current rate and the cycle life of an electrochemical cell.

  11. Metabolic rate measurement system

    NASA Technical Reports Server (NTRS)

    Koester, K.; Crosier, W.

    1980-01-01

    The Metabolic Rate Measurement System (MRMS) is an uncomplicated and accurate apparatus for measuring oxygen consumption and carbon dioxide production of a test subject. From this one can determine the subject's metabolic rate for a variety of conditions, such as resting or light exercise. MRMS utilizes an LSI/11-03 microcomputer to monitor and control the experimental apparatus.

  12. Current measuring system

    DOEpatents

    Dahl, D.A.; Appelhans, A.D.; Olson, J.E.

    1997-09-09

    A current measuring system is disclosed comprising a current measuring device having a first electrode at ground potential, and a second electrode; a current source having an offset potential of at least three hundred volts, the current source having an output electrode; and a capacitor having a first electrode electrically connected to the output electrode of the current source and having a second electrode electrically connected to the second electrode of the current measuring device. 4 figs.

  13. Current measuring system

    DOEpatents

    Dahl, David A.; Appelhans, Anthony D.; Olson, John E.

    1997-01-01

    A current measuring system comprising a current measuring device having a first electrode at ground potential, and a second electrode; a current source having an offset potential of at least three hundred volts, the current source having an output electrode; and a capacitor having a first electrode electrically connected to the output electrode of the current source and having a second electrode electrically connected to the second electrode of the current measuring device.

  14. Digital capacitance measuring system

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The hardware phase of a digital capacitance measuring system is presented with the major emphasis placed on the electrical design and operation. Test results are included of the three units fabricated. The system's interface is applicable to existing requirements for the space shuttle vehicle.

  15. Stress Measurement System

    NASA Technical Reports Server (NTRS)

    1996-01-01

    Under the Aircraft Structural Integrity program, Langley Research Center and Stress Photonics developed an infrared-based stress measurement system for use in nondestructive evaluation of materials and structures. Stress Photonics commercialized the technology in the DeltaTherm 1000 system, used to compare designs and detect cracks in structures, especially for aging aircraft and bridges. The system combines digital signal processing technology with a special infrared camera to provide instantaneous thermal images and live differential images.

  16. Video integrated measurement system.

    PubMed

    Spector, B; Eilbert, L; Finando, S; Fukuda, F

    1982-06-01

    A Video Integrated Measurement (VIM) System is described which incorporates the use of various noninvasive diagnostic procedures (moire contourography, electromyography, posturometry, infrared thermography, etc.), used individually or in combination, for the evaluation of neuromusculoskeletal and other disorders and their management with biofeedback and other therapeutic procedures. The system provides for measuring individual diagnostic and therapeutic modes, or multiple modes by split screen superimposition, of real time (actual) images of the patient and idealized (ideal-normal) models on a video monitor, along with analog and digital data, graphics, color, and other transduced symbolic information. It is concluded that this system provides an innovative and efficient method by which the therapist and patient can interact in biofeedback training/learning processes and holds considerable promise for more effective measurement and treatment of a wide variety of physical and behavioral disorders.

  17. Oceanic wave measurement system

    NASA Technical Reports Server (NTRS)

    Holmes, J. F.; Miles, R. T. (Inventor)

    1980-01-01

    An oceanic wave measured system is disclosed wherein wave height is sensed by a barometer mounted on a buoy. The distance between the trough and crest of a wave is monitored by sequentially detecting positive and negative peaks of the output of the barometer and by combining (adding) each set of two successive half cycle peaks. The timing of this measurement is achieved by detecting the period of a half cycle of wave motion.

  18. Sensorimotor System Measurement Techniques

    PubMed Central

    Riemann, Bryan L.; Myers, Joseph B.; Lephart, Scott M.

    2002-01-01

    Objective: To provide an overview of currently available sensorimotor assessment techniques. Data Sources: We drew information from an extensive review of the scientific literature conducted in the areas of proprioception, neuromuscular control, and motor control measurement. Literature searches were conducted using MEDLINE for the years 1965 to 1999 with the key words proprioception, somatosensory evoked potentials, nerve conduction testing, electromyography, muscle dynamometry, isometric, isokinetic, kinetic, kinematic, posture, equilibrium, balance, stiffness, neuromuscular, sensorimotor, and measurement. Additional sources were collected using the reference lists of identified articles. Data Synthesis: Sensorimotor measurement techniques are discussed with reference to the underlying physiologic mechanisms, influential factors and locations of the variable within the system, clinical research questions, limitations of the measurement technique, and directions for future research. Conclusions/Recommendations: The complex interactions and relationships among the individual components of the sensorimotor system make measuring and analyzing specific characteristics and functions difficult. Additionally, the specific assessment techniques used to measure a variable can influence attained results. Optimizing the application of sensorimotor research to clinical settings can, therefore, be best accomplished through the use of common nomenclature to describe underlying physiologic mechanisms and specific measurement techniques. PMID:16558672

  19. Optical measurement systems

    NASA Technical Reports Server (NTRS)

    Lesco, Daniel J.

    1990-01-01

    Some of the areas of research conducted at the LeRC on optical measurement techniques for propulsion systems research are described. Most of the optical techniques used to measure gas parameters depend on very inefficient light scattering principles and, therefore, require the high light intensities provided by lasers. Significant advances in laser technology, together with the availability of sensitive photodetection systems, provide much of the impetus for research in optical diagnostics techniques. The goal of the research is to enhance the capabilities of nonintrusive research instrumentation to meet the special needs of aeropropulsion research. Optical techniques are being used to validate analytical codes and to verify the performance of aeropropulsion components and systems.

  20. In situ measurement system

    DOEpatents

    Lord, D.E.

    1980-11-24

    A multipurpose in situ underground measurement system comprising a plurality of long electrical resistance elements in the form of rigid reinforcing bars, each having an open loop hairpin configuration of shorter length than the other resistance elements. The resistance elements are arranged in pairs in a unitized structure, and grouted in place in the underground volume. Measurement means are provided for obtaining for each pair the electrical resistance of each element and the difference in electrical resistance of the paired elements, which difference values may be used in analytical methods involving resistance as a function of temperature. A scanner means sequentially connects the resistance-measuring apparatus to each individual pair of elements. A source of heating current is also selectively connectable for heating the elements to an initial predetermined temperature prior to electrical resistance measurements when used as an anemometer.

  1. Laser angle measurement system

    NASA Technical Reports Server (NTRS)

    Pond, C. R.; Texeira, P. D.; Wilbert, R. E.

    1980-01-01

    The design and fabrication of a laser angle measurement system is described. The instrument is a fringe counting interferometer that monitors the pitch attitude of a model in a wind tunnel. A laser source and detector are mounted above the mode. Interference fringes are generated by a small passive element on the model. The fringe count is accumulated and displayed by a processor in the wind tunnel control room. Optical and electrical schematics, system maintenance and operation procedures are included, and the results of a demonstration test are given.

  2. Measurement Technology System

    DTIC Science & Technology

    2015-05-29

    Abstract The Measurement Technology System (MTS) is a complex robotic system mated to a state of the art LEICA Laser Tracker/Scanner to provide...Tracker could maintain both a “ laser lock” on one of the four reflectors as well as a valid “6 DoF”, which is accomplished when the Tracker can...Manually “Tweaking” to preserve Laser Lock and “6 DoF”  Integrating the MTS Application with the Robot Motion Programs The full scale MTS was

  3. Wear Measurement System

    NASA Technical Reports Server (NTRS)

    1995-01-01

    Lewis Research Center developed a tribometer for in-house wear tests. Implant Sciences Corporation (ISC), working on a NASA contract to develop coatings to enhance the wear capabilities of materials, adapted the tribometer for its own use and developed a commercial line of user-friendly systems. The ISC-200 is a pin-on-disk type of tribometer, functioning like a record player and creating a wear groove on the disk, with variables of speed and load. The system can measure the coefficient of friction, the wear behavior between materials, and the integrity of thin films or coatings. Applications include measuring wear on contact lenses and engine parts and testing disk drives.

  4. Optical absorption measurement system

    DOEpatents

    Draggoo, Vaughn G.; Morton, Richard G.; Sawicki, Richard H.; Bissinger, Horst D.

    1989-01-01

    The system of the present invention contemplates a non-intrusive method for measuring the temperature rise of optical elements under high laser power optical loading to determine the absorption coefficient. The method comprises irradiating the optical element with a high average power laser beam, viewing the optical element with an infrared camera to determine the temperature across the optical element and calculating the absorption of the optical element from the temperature.

  5. Microgravity Acceleration Measurement System

    NASA Technical Reports Server (NTRS)

    Foster, William

    2009-01-01

    Microgravity Acceleration Measurement System (MAMS) is an ongoing study of the small forces (vibrations and accelerations) on the ISS that result from the operation of hardware, crew activities, as well as dockings and maneuvering. Results will be used to generalize the types of vibrations affecting vibration-sensitive experiments. Investigators seek to better understand the vibration environment on the space station to enable future research.

  6. System for Measuring Capacitance

    NASA Technical Reports Server (NTRS)

    McNichol, Randal S. (Inventor)

    2001-01-01

    A system has been developed for detecting the level of a liquid in a tank wherein a capacitor positioned in the tank has spaced plates which are positioned such that the dielectric between the plates will be either air or the liquid, depending on the depth of the liquid in the tank. An oscillator supplies a sine wave current to the capacitor and a coaxial cable connects the capacitor to a measuring circuit outside the tank. If the cable is very long or the capacitance to be measured is low, the capacitance inherent in the coaxial cable will prevent an accurate reading. To avoid this problem, an inductor is connected across the cable to form with the capacitance of the cable a parallel resonant circuit. The impedance of the parallel resonant circuit is infinite, so that attenuation of the measurement signal by the stray cable capacitance is avoided.

  7. Contour measurement system

    NASA Technical Reports Server (NTRS)

    Currie, J. R.; Kissel, R. R.; Deaton, E. T., Jr.; Campbell, R. A. (Inventor)

    1979-01-01

    A measurement system for measuring the departures from a straight line of discrete track sections of a track along a coal face in a mine employing a vehicle having a pair of spaced wheel assemblies which align with the track is presented. A reference arm pivotally connects between the wheel assemblies, and there is indicating means for measuring the angle of pivot between the arm and each of the wheel assemblies. The length of the device is less than the length of a track section, and thus when one of the wheel assemblies is on one track section and one is on an adjoining track section, the sum of the indicated angles will be indicative of the angle between track sections. Thus, from the length of a track section and angle, the departure of each track section from the line may be calculated.

  8. Wireless Acoustic Measurement System

    NASA Technical Reports Server (NTRS)

    Anderson, Paul D.; Dorland, Wade D.

    2005-01-01

    A prototype wireless acoustic measurement system (WAMS) is one of two main subsystems of the Acoustic Prediction/Measurement Tool, which comprises software, acoustic instrumentation, and electronic hardware combined to afford integrated capabilities for predicting and measuring noise emitted by rocket and jet engines. The other main subsystem is described in "Predicting Rocket or Jet Noise in Real Time" (SSC-00215-1), which appears elsewhere in this issue of NASA Tech Briefs. The WAMS includes analog acoustic measurement instrumentation and analog and digital electronic circuitry combined with computer wireless local-area networking to enable (1) measurement of sound-pressure levels at multiple locations in the sound field of an engine under test and (2) recording and processing of the measurement data. At each field location, the measurements are taken by a portable unit, denoted a field station. There are ten field stations, each of which can take two channels of measurements. Each field station is equipped with two instrumentation microphones, a micro-ATX computer, a wireless network adapter, an environmental enclosure, a directional radio antenna, and a battery power supply. The environmental enclosure shields the computer from weather and from extreme acoustically induced vibrations. The power supply is based on a marine-service lead-acid storage battery that has enough capacity to support operation for as long as 10 hours. A desktop computer serves as a control server for the WAMS. The server is connected to a wireless router for communication with the field stations via a wireless local-area network that complies with wireless-network standard 802.11b of the Institute of Electrical and Electronics Engineers. The router and the wireless network adapters are controlled by use of Linux-compatible driver software. The server runs custom Linux software for synchronizing the recording of measurement data in the field stations. The software includes a module that

  9. Wireless Acoustic Measurement System

    NASA Technical Reports Server (NTRS)

    Anderson, Paul D.; Dorland, Wade D.; Jolly, Ronald L.

    2007-01-01

    A prototype wireless acoustic measurement system (WAMS) is one of two main subsystems of the Acoustic Prediction/ Measurement Tool, which comprises software, acoustic instrumentation, and electronic hardware combined to afford integrated capabilities for predicting and measuring noise emitted by rocket and jet engines. The other main subsystem is described in the article on page 8. The WAMS includes analog acoustic measurement instrumentation and analog and digital electronic circuitry combined with computer wireless local-area networking to enable (1) measurement of sound-pressure levels at multiple locations in the sound field of an engine under test and (2) recording and processing of the measurement data. At each field location, the measurements are taken by a portable unit, denoted a field station. There are ten field stations, each of which can take two channels of measurements. Each field station is equipped with two instrumentation microphones, a micro- ATX computer, a wireless network adapter, an environmental enclosure, a directional radio antenna, and a battery power supply. The environmental enclosure shields the computer from weather and from extreme acoustically induced vibrations. The power supply is based on a marine-service lead-acid storage battery that has enough capacity to support operation for as long as 10 hours. A desktop computer serves as a control server for the WAMS. The server is connected to a wireless router for communication with the field stations via a wireless local-area network that complies with wireless-network standard 802.11b of the Institute of Electrical and Electronics Engineers. The router and the wireless network adapters are controlled by use of Linux-compatible driver software. The server runs custom Linux software for synchronizing the recording of measurement data in the field stations. The software includes a module that provides an intuitive graphical user interface through which an operator at the control server

  10. Blade Vibration Measurement System

    NASA Technical Reports Server (NTRS)

    Platt, Michael J.

    2014-01-01

    The Phase I project successfully demonstrated that an advanced noncontacting stress measurement system (NSMS) could improve classification of blade vibration response in terms of mistuning and closely spaced modes. The Phase II work confirmed the microwave sensor design process, modified the sensor so it is compatible as an upgrade to existing NSMS, and improved and finalized the NSMS software. The result will be stand-alone radar/tip timing radar signal conditioning for current conventional NSMS users (as an upgrade) and new users. The hybrid system will use frequency data and relative mode vibration levels from the radar sensor to provide substantially superior capabilities over current blade-vibration measurement technology. This frequency data, coupled with a reduced number of tip timing probes, will result in a system capable of detecting complex blade vibrations that would confound traditional NSMS systems. The hardware and software package was validated on a compressor rig at Mechanical Solutions, Inc. (MSI). Finally, the hybrid radar/tip timing NSMS software package and associated sensor hardware will be installed for use in the NASA Glenn spin pit test facility.

  11. SUMP MEASURING SYSTEM

    SciTech Connect

    Vrettos, N; Athneal Marzolf, A; Casandra Robinson, C; James Fiscus, J; Daniel Krementz, D; Thomas Nance, T

    2007-11-26

    The process sumps in H-Canyon at the Savannah River Site (SRS) collect leaks from process tanks and jumpers. To prevent build-up of fissile material the sumps are frequently flushed which generates liquid waste and is prone to human error. The development of inserts filled with a neutron poison will allow a reduction in the frequency of flushing. Due to concrete deterioration and deformation of the sump liners the current dimensions of the sumps are unknown. Knowledge of these dimensions is necessary for development of the inserts. To solve this problem a remote Sump Measurement System was designed, fabricated, and tested to aid development of the sump inserts.

  12. Thermal microstructure measurement system

    NASA Technical Reports Server (NTRS)

    Carver, Michael J. (Inventor)

    1985-01-01

    A thermal microstructure measurement system (TMMS) operates autonomously h its own internal power supply and telemeters data to a platform. A thermal array is mounted on a cross-braced frame designed to orient itself normal to existing currents with fixed sensor positioning bars protruding from the cross bars. A plurality of matched thermistors, conductivity probes and inclinometers are mounted on the frame. A compass and pressure transducer are contained in an electronics package suspended below the array. The array is deployed on a taut mooring below a subsurface float. Data are digitized, transmitted via cable to a surface buoy and then telemetered to the platform where the data is processed via a computer, recorded and/or displayed. The platform computer also sends commands to the array via telemetry.

  13. Measurement System and Method

    NASA Technical Reports Server (NTRS)

    Arndt, G. Dickey (Inventor); Ngo, Phong H. (Inventor); Carl, James R. (Inventor); Byerly, Kent A. (Inventor)

    2003-01-01

    System and methods are disclosed for fluid measurements which may be utilized to determine mass flow rates such as instantaneous mass flow of a fluid stream. In a preferred embodiment, the present invention may be utilized to compare an input mass flow to an output mass flow of a drilling fluid circulation stream. In one embodiment, a fluid flow rate is determined by utilizing a microwave detector in combination with an acoustic sensor. The acoustic signal is utilized to eliminate 2pi phase ambiguities in a reflected microwave signal. In another embodiment, a fluid flow rate may be determined by detecting a phase shift of an acoustic signal across two different predetermined transmission paths. A fluid density may be determined by detecting a calibrated phase shift of an acoustic signal through the fluid. In another embodiment, a second acoustic signal may be transmitted through the fluid to define a particular 2pi phase range which defines the phase shift. The present invention may comprise multiple transmitters/receivers operating at different frequencies to measure instantaneous fuel levels of cryogenic fuels within containers positioned in zero or near zero gravity environments. In one embodiment, a moveable flexible collar of transmitter/receivers may be utilized to determine inhomogenuities within solid rocket fuel tubes.

  14. Coordinate measuring system

    DOEpatents

    Carlisle, Keith

    2003-04-08

    An apparatus and method is utilized to measure relative rigid body motion between two bodies by measuring linear motion in the principal axis and linear motion in an orthogonal axis. From such measurements it is possible to obtain displacement, departure from straightness, and angular displacement from the principal axis of a rigid body.

  15. Mining volume measurement system

    NASA Technical Reports Server (NTRS)

    Heyman, Joseph Saul (Inventor)

    1988-01-01

    In a shaft with a curved or straight primary segment and smaller off-shooting segments, at least one standing wave is generated in the primary segment. The shaft has either an open end or a closed end and approximates a cylindrical waveguide. A frequency of a standing wave that represents the fundamental mode characteristic of the primary segment can be measured. Alternatively, a frequency differential between two successive harmonic modes that are characteristic of the primary segment can be measured. In either event, the measured frequency or frequency differential is characteristic of the length and thus the volume of the shaft based on length times the bore area.

  16. Objective Color Measuring System

    DTIC Science & Technology

    1982-09-01

    F. W. Billmeyer , Jr., Comparative performance of color measuring instruments, Appl. Optics 8, 775-783 (1969). 3 F. W. Billmeyer , Jr., E. D. Campbell...comments, Appl. Optics 14, 265 (1975). 4 R. T. Marcus and F. W. Billmeyer , Jr., Statistical study of color-measurement instrumentation, Appl. Optics 13... Billmeyer , Jr. and P. J. Alessi, Assessment of color-manuring instruments for objective textile acceptability judgment, NATICK/TR-79/044, US Army Natick R

  17. Systems Measures of Water Distribution System Resilience

    SciTech Connect

    Klise, Katherine A.; Murray, Regan; Walker, La Tonya Nicole

    2015-01-01

    Resilience is a concept that is being used increasingly to refer to the capacity of infrastructure systems to be prepared for and able to respond effectively and rapidly to hazardous events. In Section 2 of this report, drinking water hazards, resilience literature, and available resilience tools are presented. Broader definitions, attributes and methods for measuring resilience are presented in Section 3. In Section 4, quantitative systems performance measures for water distribution systems are presented. Finally, in Section 5, the performance measures and their relevance to measuring the resilience of water systems to hazards is discussed along with needed improvements to water distribution system modeling tools.

  18. Pollution Measuring System

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Research Ventures, Inc.'s visiplume is a portable, microprocessor-controlled air pollution monitor for measuring sulfur dioxide emissions from fossil fuel-fired power plants, and facilities that manufacture sulfuric acid. It observes smokestack plumes at a distance from the stack obviating the expense and difficulty of installing sample collectors in each stack and later analyzing the samples.

  19. Automated ac galvanomagnetic measurement system

    NASA Technical Reports Server (NTRS)

    Szofran, F. R.; Espy, P. N.

    1985-01-01

    An automated, ac galvanomagnetic measurement system is described. Hall or van der Pauw measurements in the temperature range 10-300 K can be made at a preselected magnetic field without operator attendance. Procedures to validate sample installation and correct operation of other system functions, such as magnetic field and thermometry, are included. Advantages of ac measurements are discussed.

  20. Measurement Systems Advisory Group

    DTIC Science & Technology

    1974-04-01

    noted with the aluminum wire used in the lacing. For these reasons the tests were concluded and deemed unsatisfactory. The second system tested was an...vehicle for "bringing many particulate pollutants into contact with the tape or magnetic heads, e.g., from deodorant spray powders, face powder and

  1. Microbial ecology measurement system

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The sensitivity and potential rapidity of the PIA test that was demonstrated during the feasibility study warranted continuing the effort to examine the possibility of adapting this test to an automated procedure that could be used during manned missions. The effort during this program has optimized the test conditions for two important respiratory pathogens, influenza virus and Mycoplasma pneumoniae, developed a laboratory model automated detection system, and investigated a group antigen concept for virus detection. Preliminary tests on the handling of oropharygeal clinical samples for PIA testing were performed using the adenovirus system. The results obtained indicated that the PIA signal is reduced in positive samples and is increased in negative samples. Treatment with cysteine appeared to reduce nonspecific agglutination in negative samples but did not maintain the signal in positive samples.

  2. Purchasing Productivity Measurement Systems.

    DTIC Science & Technology

    1980-09-01

    Defense More Productive", Perspectives in Defense Management, Winter 1974-1975. 4. Encyclopaedia Britannica, Macropaedia, " Taylor , Frederick Winslow ", v...Some of the earliest successes in Productivity Systems and studies are attributed to Frederick W. Taylor and his concept of Scientific Management...sociological interactions. Taylorism , as it became known, provoked resentment and opposition from labor when it was carried to extremes. It was, however

  3. Ozone measurement systems improvements studies

    NASA Technical Reports Server (NTRS)

    Thomas, R. W.; Guard, K.; Holland, A. C.; Spurling, J. F.

    1974-01-01

    Results are summarized of an initial study of techniques for measuring atmospheric ozone, carried out as the first phase of a program to improve ozone measurement techniques. The study concentrated on two measurement systems, the electro chemical cell (ECC) ozonesonde and the Dobson ozone spectrophotometer, and consisted of two tasks. The first task consisted of error modeling and system error analysis of the two measurement systems. Under the second task a Monte-Carlo model of the Dobson ozone measurement technique was developed and programmed for computer operation.

  4. Tissue oxygen measurement system

    NASA Technical Reports Server (NTRS)

    Soller, Babs R. (Inventor)

    2004-01-01

    A device and method in accordance with the invention for determining the oxygen partial pressure (PO.sub.2) of a tissue by irradiating the tissue with optical radiation such that the light is emitted from the tissue, and by collecting the reflected or transmitted light from the tissue to form an optical spectrum. A spectral processor determines the PO.sub.2 level in tissue by processing this spectrum with a previously-constructed spectral calibration model. The tissue may, for example, be disposed underneath a covering tissue, such as skin, of a patient, and the tissue illuminated and light collected through the skin. Alternatively, direct tissue illumination and collection may be effected with a hand-held or endoscopic probe. A preferred system also determines pH from the same spectrum, and the processor may determine critical conditions and issue warnings based on parameter values.

  5. Achilles tendon reflex measuring system

    NASA Astrophysics Data System (ADS)

    Szebeszczyk, Janina; Straszecka, Joanna

    1995-06-01

    The examination of Achilles tendon reflex is widely used as a simple, noninvasive clinical test in diagnosis and pharmacological therapy monitoring in such diseases as: hypothyroidism, hyperthyroidism, diabetic neuropathy, the lower limbs obstructive angiopathies and intermittent claudication. Presented Achilles tendon reflect measuring system is based on the piezoresistive sensor connected with the cylinder-piston system. To determinate the moment of Achilles tendon stimulation a detecting circuit was used. The outputs of the measuring system are connected to the PC-based data acquisition board. Experimental results showed that the measurement accuracy and repeatability is good enough for diagnostics and therapy monitoring purposes. A user friendly, easy-to-operate measurement system fulfills all the requirements related to recording, presentation and storing of the patients' reflexograms.

  6. Endovascular blood flow measurement system

    NASA Astrophysics Data System (ADS)

    Khe, A. K.; Cherevko, A. A.; Chupakhin, A. P.; Krivoshapkin, A. L.; Orlov, K. Yu

    2016-06-01

    In this paper an endovascular measurement system used for intraoperative cerebral blood flow monitoring is described. The system is based on a Volcano ComboMap Pressure and Flow System extended with analogue-to-digital converter and PC laptop. A series of measurements performed in patients with cerebrovascular pathologies allows us to introduce “velocity-pressure” and “flow rate-energy flow rate” diagrams as important characteristics of the blood flow. The measurement system presented here can be used as an additional instrument in neurosurgery for assessment and monitoring of the operation procedure. Clinical data obtained with the system are used for construction of mathematical models and patient-specific simulations. The monitoring of the blood flow parameters during endovascular interventions was approved by the Ethics Committee at the Meshalkin Novosibirsk Research Institute of Circulation Pathology and included in certain surgical protocols for pre-, intra- and postoperative examinations.

  7. Mass properties measurement system dynamics

    NASA Technical Reports Server (NTRS)

    Doty, Keith L.

    1993-01-01

    The MPMS mechanism possess two revolute degrees-of-freedom and allows the user to measure the mass, center of gravity, and the inertia tensor of an unknown mass. The dynamics of the Mass Properties Measurement System (MPMS) from the Lagrangian approach to illustrate the dependency of the motion on the unknown parameters.

  8. Measures of Autonomic Nervous System

    DTIC Science & Technology

    2011-04-01

    optimal level of the individual’s lung function is measured by using three color-coded peak flow zones. The individual monitoring and peak flow monitor... monoamine oxidase inhibitors, which may interfere with accurate measurements of catecholamine metabolites. Three tools for measuring catecholamine...monitoring system for patient transport . IEEE Trans Inf Technol Biomed. 2004;8(4):439. 25. Blank JM, Altman DG. Statistical methods for assessing

  9. Portable Positron Measurement System (PPMS)

    SciTech Connect

    2011-01-01

    Portable Positron Measurement System (PPMS) is an automated, non-destructive inspection system based on positron annihilation, which characterizes a material's in situatomic-level properties during the manufacturing processes of formation, solidification, and heat treatment. Simultaneous manufacturing and quality monitoring now are possible. Learn more about the lab's project on our facebook site http://www.facebook.com/idahonationallaboratory.

  10. Portable Positron Measurement System (PPMS)

    ScienceCinema

    None

    2016-07-12

    Portable Positron Measurement System (PPMS) is an automated, non-destructive inspection system based on positron annihilation, which characterizes a material's in situatomic-level properties during the manufacturing processes of formation, solidification, and heat treatment. Simultaneous manufacturing and quality monitoring now are possible. Learn more about the lab's project on our facebook site http://www.facebook.com/idahonationallaboratory.

  11. Airborne Atmospheric Aerosol Measurement System

    NASA Astrophysics Data System (ADS)

    Ahn, K.; Park, Y.; Eun, H.; Lee, H.

    2015-12-01

    It is important to understand the atmospheric aerosols compositions and size distributions since they greatly affect the environment and human health. Particles in the convection layer have been a great concern in global climate changes. To understand these characteristics satellite, aircraft, and radio sonde measurement methods have usually been used. An aircraft aerosol sampling using a filter and/or impactor was the method commonly used (Jay, 2003). However, the flight speed particle sampling had some technical limitations (Hermann, 2001). Moreover, the flight legal limit, altitude, prohibited airspace, flight time, and cost was another demerit. To overcome some of these restrictions, Tethered Balloon Package System (T.B.P.S.) and Recoverable Sonde System(R.S.S.) were developed with a very light optical particle counter (OPC), impactor, and condensation particle counter (CPC). Not only does it collect and measure atmospheric aerosols depending on altitudes, but it also monitors the atmospheric conditions, temperature, humidity, wind velocity, pressure, GPS data, during the measurement (Eun, 2013). In this research, atmospheric aerosol measurement using T.B.P.S. in Ansan area is performed and the measurement results will be presented. The system can also be mounted to an unmanned aerial vehicle (UAV) and create an aerial particle concentration map. Finally, we will present measurement data using Tethered Balloon Package System (T.B.P.S.) and R.S.S (Recoverable Sonde System).

  12. Rotor component displacement measurement system

    DOEpatents

    Mercer, Gary D.; Li, Ming C.; Baum, Charles R.

    2003-05-27

    A measuring system for measuring axial displacement of a tube relative to an axially stationary component in a rotating rotor assembly includes at least one displacement sensor adapted to be located normal to a longitudinal axis of the tube; an insulated cable system adapted for passage through the rotor assembly; a rotatable proximitor module located axially beyond the rotor assembly to which the cables are connected; and a telemetry system operatively connected to the proximitor module for sampling signals from the proximitor module and forwarding data to a ground station.

  13. Portable plant health measurement system

    NASA Astrophysics Data System (ADS)

    Aksoy, Nejat

    1999-01-01

    This system is designed to assist diagnosis of the plant health globally. The system is formed by portable plant health measurement devices connected to a diagnosis and analysis center through a flexible information network. A flexible network is formed so that users from the remote areas as well as internet are able to use the system. The hardware and software is designed in an open technology for easier upgrades. Portable plant health measurement instrument is a networkable leaf flash spectrophotometer capable of measuring Qa, Electrochromy, P700, Fluorescence, S Fluorescence, reflectance spectra, temperature, humidity and image of the leaf with GPS information. The network and intelligent user interface options of the system can be used by any commercially or user designed instrument.

  14. Inflight lightning characteristics measurement system

    NASA Technical Reports Server (NTRS)

    Pitts, F. L.; Thomas, M. E.; Campbell, R. E.; Thomas, R. M.; Zaepfel, K. P.

    1979-01-01

    A research data-gathering system being developed for inflight measurement of direct and nearby lightning strike characteristics is described. Wideband analog recorders used to record the lightning scenario are supplemented with high-sample-rate digital transient recorders with augmented memory capacity for increased time resolution of specific times of interest. The endless-loop data storage technique employed by the transient recorders circumvents problems associated with oscilloscopic techniques and allows unattended operation. System integrity and immunity from induced effects is accomplished by fiber-optics signal-transmission links, shielded system enclosures, and the use of a dynamotor for power system isolation.

  15. System to measure heart performance

    NASA Astrophysics Data System (ADS)

    Andrade, Armando; Rios, Heriberto; Lizana, Pablo R.; Puente, Ernestina; Mendoza, Diego

    2002-11-01

    Systems to measure heart condition are applied to patients with early or chronic cardiac problems with the aim of diagnosing and exactly locat- ing the problem. Two very important factors exist that are taken into account in order to obtain a reliable diagnosis and to be able to give suitable medical treatment. One of them is the volume of blood that the heart pumps, the other is the temperature gradient. In our system we measure both parameters at the same time with the purpose of determining how the heart is working from the amount of blood pumped per unit time. (To be presented in Spanish.)

  16. Tracer airflow measurement system (TRAMS)

    DOEpatents

    Wang, Duo

    2007-04-24

    A method and apparatus for measuring fluid flow in a duct is disclosed. The invention uses a novel high velocity tracer injector system, an optional insertable folding mixing fan for homogenizing the tracer within the duct bulk fluid flow, and a perforated hose sampling system. A preferred embodiment uses CO.sub.2 as a tracer gas for measuring air flow in commercial and/or residential ducts. In extant commercial buildings, ducts not readily accessible by hanging ceilings may be drilled with readily plugged small diameter holes to allow for injection, optional mixing where desired using a novel insertable foldable mixing fan, and sampling hose.

  17. Near Field Antenna Measurement System.

    DTIC Science & Technology

    1982-03-01

    beam pointing accuracy and .6 dB gain accuracy. These antennas are both planar arrays with the X-band antenna scanning with ferrite phase shifters in...AD-A114 125 M[ES AIRCRAFT CO FULLERTON CA F/ 17/9 NEAR FIELD ANTENNA MEASUREMENT SYSTEM. (U) MAR 82 A E HOLLEY DAABO7-7?-C-1 87 UNCLASSIFIED NL...IllIHE El. onhEnoh IIIIhh --h h I~m I I Research and Development Technical Report I DAABO7-77-C-0587-F1 NEAR FIELD ANTENNA I MEASUREMENT SYSTEM I A.E

  18. Automated intensifier tube measuring system

    NASA Astrophysics Data System (ADS)

    Partee, J.; Paul, C.; Sartor, M.; West, J.; Wichowski, N.; McIntyre, B.

    2008-04-01

    Image Intensifier Tube (IIT) technology remains a critical component of the warfighter's arsenal. However, even after six decades of fielded systems most IIT inspections are accomplished relying on human judgment and round-robin calibration techniques. We report on the Automated Intensifier Measurement System (AIMS), a NIST-traceable, calibratable, machine vision system developed to produce automated, quantifiable, reproducible results on eight of the major IIT inspections: (1) Useful Diameter, (2) Modulation Transfer Function, (3) Gross Distortion, (4) Shear Distortion, (5) Bright Spot, (6) Dark Spot, (7) Gain and (8) Uniformity. The overall architecture of the system and a description of the algorithms required for each test is presented. Translation from the anthropocentric MIL-PRF-A3256363D(CR) OMNI VII Military Specification to measurable quantities (with appropriate uncertainties) is described. The NIST-traceable system uncertainties associated with each measurement is reported; in all cases AIMS measures quantities associated with the above tests to more precision than current industry practice. Issues with the current industry standard equipment and testing methods are also identified. Future work, which will include additional inspections, is discussed.

  19. A urine volume measurement system

    NASA Technical Reports Server (NTRS)

    Poppendiek, H. F.; Mouritzen, G.; Sabin, C. M.

    1972-01-01

    An improved urine volume measurement system for use in the unusual environment of manned space flight is reported. The system utilizes a low time-constant thermal flowmeter. The time integral of the transient response of the flowmeter gives the urine volume during a void as it occurs. In addition, the two phase flows through the flowmeter present no problem. Developments of the thermal flowmeter and a verification of the predicted performance characteristics are summarized.

  20. Ground-truth measurement systems

    NASA Technical Reports Server (NTRS)

    Serafin, R.; Seliga, T. A.; Lhermitte, R. M.; Nystuen, J. A.; Cherry, S.; Bringi, V. N.; Blackmer, R.; Heymsfield, G. M.

    1981-01-01

    Ground-truth measurements of precipitation and related weather events are an essential component of any satellite system designed for monitoring rainfall from space. Such measurements are required for testing, evaluation, and operations; they provide detailed information on the actual weather events, which can then be compared with satellite observations intended to provide both quantitative and qualitative information about them. Also, very comprehensive ground-truth observations should lead to a better understanding of precipitation fields and their relationships to satellite data. This process serves two very important functions: (a) aiding in the development and interpretation of schemes of analyzing satellite data, and (b) providing a continuing method for verifying satellite measurements.

  1. Optical Strain Measurement System Development

    NASA Technical Reports Server (NTRS)

    Lant, C. T.

    1985-01-01

    Investigations of physical phenomena affecting the durability of SSME components require measurement systems operational in hostile environments. The need for such instrumentation caused the definition and operation of an optical strain measurement system. This optical strain measurement system based on the speckle shift method is being developed. This is a noncontact, automatic method of measuring surface strain in one dimension that corrects for error due to rigid body motion. It provides a gauge length of 1 to 2 mm and allows the region of interest on the test specimen to be mapped point by point. The output is a graphics map of the points inspected on the specimen; data points is stored in quasi-real time. This is the first phase of a multiphase effort in optical strain measurement. The speckle pattern created by the test specimen is interpreted as high order interference fringes resulting from a random diffraction grating, being the natural surface roughness of the specimen. Strain induced on the specimen causes a change in spacing of the surface roughness, which in turn shifts the position of the interference pattern (speckles).

  2. Optical Strain Measurement System Development

    NASA Technical Reports Server (NTRS)

    Lant, C. T.

    1985-01-01

    Investigations of physical phenomena affecting the durability of SSME components require measurement systems operational in hostile environments. The need for such instrumentation caused the definition and operation of an optical strain measurement system. This optical strain measurement system based on the speckle shift method is being developed. This is a noncontact, automatic method of measuring surface strain in one dimension that corrects for error due to rigid body motion. It provides a gauge length of 1 to 2 mm and allows the region of interest on the test specimen to be mapped point by point. The output is a graphics map of the points inspected on the specimen; data points is stored in quasi-real time. This is the first phase of a multiphase effort in optical strain measurement. The speckle pattern created by the test specimen is interpreted as high order interference fringes resulting from a random diffraction grating, being the natural surface roughness of the specimen. Strain induced on the specimen causes a change in spacing of the surface roughness, which in turn shifts the position of the interference pattern (speckles).

  3. DC Magnetics Measurement System Design

    NASA Technical Reports Server (NTRS)

    Mastny, Timothy

    2012-01-01

    This report will detail the updates to the magnetics measurement system design and testing procedures that are required for performing static (DC) magnetics testing of future flight hardware. An older magnetics testing system had to be integrated with new procedures and hardware to meet the demands of future testing programs and accommodate an upcoming magnetics tests. The next test will be for the Geostationary Operational Environmental Satellite R-Series (GOES-R), which will verify that the SAFT Battery component meets its specifications for magnetic cleanliness. The satellite is scheduled to launch in 2015 with magnetics testing to be completed on the battery in November 2012.

  4. DC Magnetics Measurement System Design

    NASA Technical Reports Server (NTRS)

    Mastny, Timothy

    2012-01-01

    This report will detail the updates to the magnetics measurement system design and testing procedures that are required for performing static (DC) magnetics testing of future flight hardware. An older magnetics testing system had to be integrated with new procedures and hardware to meet the demands of future testing programs and accommodate an upcoming magnetics tests. The next test will be for the Geostationary Operational Environmental Satellite R-Series (GOES-R), which will verify that the SAFT Battery component meets its specifications for magnetic cleanliness. The satellite is scheduled to launch in 2015 with magnetics testing to be completed on the battery in November 2012.

  5. Closed Systems that Measure Particles

    NASA Astrophysics Data System (ADS)

    Steiner, Michael; Rendell, Ronald

    2011-03-01

    The Measurement Problem has been of fundamental concern since the discovery of Schrödinger's equation. We have been developing a framework for which this problem can be considered under the assumption that the particle and detector are jointly considered a closed system. The framework is based on imposing conditions on quantum state evolution that such a closed system meet, including conservation of energy and momentum, no-cloning and no-signaling, gauge invariance, and relativity constraints. Another requirement will be presented, which is a quantum mechanical generalization of Newton's first law. Based on these conditions, we will derive and present several new results.

  6. Steam System Energy Conservation Measures

    SciTech Connect

    Ian Metzger, Jesse Dean

    2010-12-31

    This software requires inputs of simple system inventory information and calculates the energy and cost benefits of various retrofit opportunities. This tool includes energy conservation measures for: fixing steam leaks. This tool calculates energy savings, demand reduction, cost savings, and building life cycle costs including: simple payback, discounted payback, net-present value, and savings to investment ratio. In addition this tool also displays the environmental benefits of a project.

  7. Tunable models in measuring systems

    NASA Astrophysics Data System (ADS)

    Avdeev, V. P. L.; Parparov, Y. G.; Sulman, L. A.; Myshlyaev, L. P.; Polyak, A. V.

    The inclusion of tunable models in technological measuring systems, including those used in the iron and steel industry is considered. A method is proposed for the stable estimation of process parameters that consists of the anti-interference tuning of partial models of signal sources by means of robust isolation and smoothing of the informative regions of data with explicit allowance for the criteria of variability of residues and the estimates themselves.

  8. In-situ measurement system

    DOEpatents

    Lord, David E.

    1983-01-01

    A multipurpose in situ underground measurement system comprising a plurality of long electrical resistance elements in the form of rigid reinforcing bars, each having an open loop "hairpin" configuration of shorter length than the other resistance elements. The resistance elements are arranged in pairs in a unitized structure, and grouted in place in the underground volume. The electrical resistance of each element and the difference in electrical resistance of the paired elements are obtained, which difference values may be used in analytical methods involving resistance as a function of temperature. A scanner sequentially connects the resistance-measuring apparatus to each individual pair of elements. A source of heating current is also selectively connectable for heating the elements to an initial predetermined temperature prior to electrical resistance measurements when used as an anemometer.

  9. Wireless sap flow measurement system

    NASA Astrophysics Data System (ADS)

    Kuo, C.; Davis, T. W.; Tseng, C.; Cheng, C.; Liang, X.; Yu, P.

    2010-12-01

    This study exhibits a measurement system for wireless sensor networks to measure sap flow in multiple locations simultaneously. Transpiration is a major component of the land-surface system because it is indicative of the water movement between the soil and the air. Sap flow can be used to approximate transpiration. In forests, transpiration cannot be represented by the sap flow from a single tree. Multi-location sap flow measurements are required to show the heterogeneity caused by different trees or soil conditions. Traditional multi-location measurements require manpower and capital for data collection and instrument maintenance. Fortunately, multi-location measurements can be achieved by using the new technology of wireless sensor networks. With multi-hop communication protocol, data can be forwarded to the base station via multiple sensor nodes. This communication protocol can provide reliable data collection with the least power consumption. This study encountered two major problems. The first problem was signal amplification. The Crossbow IRIS mote was selected as the sensor node that receives the temperature data of the sap flow probe (thermocouple) through a MDA300 data acquisition board. However, the wireless sensor node could not directly receive any data from the thermocouples since the least significant bit value of the MDA300, 0.6 mV, is much higher than the voltage signal generated. Thus, the signal from the thermocouple must be amplified to exceed this threshold. The second problem is power management. A specific heat differential is required for the thermal dissipation method of measuring sap flow. Thus, an adjustable DC power supply is necessary for calibrating the heater's temperature settings. A circuit was designed to combine the signal amplifier and power regulator. The regulator has been designed to also provide power to the IRIS mote to extend battery life. This design enables wireless sap flow measurements in the forest. With the

  10. Stochastic measurements and systems implications

    NASA Astrophysics Data System (ADS)

    Collins, J. L.; Greene, R. R.

    1985-06-01

    The U.S. Navy is defining the baseline performance of the current SSN ASW suite in the Arctic operating environment. This suite includes the AN/BQQ-5 sonar suit (including the Towed Array, the sphere and other sensor and processor sub-systems), communications subsystems and weapon systems (Mk 48 and ADCAP). An effective acoustic measurement program in the Arctic must support the evaluation of how well the different subsystems are able to carry out their assigned functions. Unique aspects of the operating environment in the Arctic include unusual noise properties, unusual transmission effects and an unusual sea surface. This report addresses those acoustic transmission effects which affect system performance due to fluctuations or spreads in the acoustic field space, angle time and frequency.

  11. Lightweight, Miniature Inertial Measurement System

    NASA Technical Reports Server (NTRS)

    Tang, Liang; Crassidis, Agamemnon

    2012-01-01

    A miniature, lighter-weight, and highly accurate inertial navigation system (INS) is coupled with GPS receivers to provide stable and highly accurate positioning, attitude, and inertial measurements while being subjected to highly dynamic maneuvers. In contrast to conventional methods that use extensive, groundbased, real-time tracking and control units that are expensive, large, and require excessive amounts of power to operate, this method focuses on the development of an estimator that makes use of a low-cost, miniature accelerometer array fused with traditional measurement systems and GPS. Through the use of a position tracking estimation algorithm, onboard accelerometers are numerically integrated and transformed using attitude information to obtain an estimate of position in the inertial frame. Position and velocity estimates are subject to drift due to accelerometer sensor bias and high vibration over time, and so require the integration with GPS information using a Kalman filter to provide highly accurate and reliable inertial tracking estimations. The method implemented here uses the local gravitational field vector. Upon determining the location of the local gravitational field vector relative to two consecutive sensors, the orientation of the device may then be estimated, and the attitude determined. Improved attitude estimates further enhance the inertial position estimates. The device can be powered either by batteries, or by the power source onboard its target platforms. A DB9 port provides the I/O to external systems, and the device is designed to be mounted in a waterproof case for all-weather conditions.

  12. Aerial Measuring System Sensor Modeling

    SciTech Connect

    R. S. Detwiler

    2002-04-01

    This project deals with the modeling the Aerial Measuring System (AMS) fixed-wing and rotary-wing sensor systems, which are critical U.S. Department of Energy's National Nuclear Security Administration (NNSA) Consequence Management assets. The fixed-wing system is critical in detecting lost or stolen radiography or medical sources, or mixed fission products as from a commercial power plant release at high flying altitudes. The helicopter is typically used at lower altitudes to determine ground contamination, such as in measuring americium from a plutonium ground dispersal during a cleanup. Since the sensitivity of these instruments as a function of altitude is crucial in estimating detection limits of various ground contaminations and necessary count times, a characterization of their sensitivity as a function of altitude and energy is needed. Experimental data at altitude as well as laboratory benchmarks is important to insure that the strong effects of air attenuation are modeled correctly. The modeling presented here is the first attempt at such a characterization of the equipment for flying altitudes. The sodium iodide (NaI) sensors utilized with these systems were characterized using the Monte Carlo N-Particle code (MCNP) developed at Los Alamos National Laboratory. For the fixed wing system, calculations modeled the spectral response for the 3-element NaI detector pod and High-Purity Germanium (HPGe) detector, in the relevant energy range of 50 keV to 3 MeV. NaI detector responses were simulated for both point and distributed surface sources as a function of gamma energy and flying altitude. For point sources, photopeak efficiencies were calculated for a zero radial distance and an offset equal to the altitude. For distributed sources approximating an infinite plane, gross count efficiencies were calculated and normalized to a uniform surface deposition of 1 {micro}Ci/m{sup 2}. The helicopter calculations modeled the transport of americium-241 ({sup 241}Am

  13. The Solar System/El Sistema Solar--A Fully Integrated Instructional Unit.

    ERIC Educational Resources Information Center

    Van Heukelem, Tom; Mercado, Maria de Jesus

    This lesson plan for the second grade uses information on the solar system to provide science education for limited-English-proficient (LEP) students in San Diego, California. The lesson has been developed to be taught in a bilingual class, a Spanish-language immersion class, or a two-way bilingual class. Lessons are arranged so that native…

  14. Investigacion Participativa y Gestion de Sistemas Educativos. (Participatory Research and the Management of Educational Systems).

    ERIC Educational Resources Information Center

    Valle, Victor M.

    Elements which, when put in harmony, might generate powerful tools for social change and educational development are (1) the ever present need of the educational systems to evaluate their performance; (2) the universal acceptance of the life-long education concept as a major guideline to design educational programs; (3) the trend toward a…

  15. Theories, Models, and Standard Systems of Measurement.

    ERIC Educational Resources Information Center

    Aftanas, Marion S.

    1988-01-01

    A meta-theoretical framework that begins with the standard system of measurement is outlined. Identification of different standard systems and elements of the measurement process provide a focus for comparisons between measurement theories and models. (SLD)

  16. System for measuring film thickness

    DOEpatents

    Batishko, Charles R.; Kirihara, Leslie J.; Peters, Timothy J.; Rasmussen, Donald E.

    1990-01-01

    A system for determining the thicknesses of thin films of materials exhibiting fluorescence in response to exposure to excitation energy from a suitable source of such energy. A section of film is illuminated with a fixed level of excitation energy from a source such as an argon ion laser emitting blue-green light. The amount of fluorescent light produced by the film over a limited area within the section so illuminated is then measured using a detector such as a photomultiplier tube. Since the amount of fluorescent light produced is a function of the thicknesses of thin films, the thickness of a specific film can be determined by comparing the intensity of fluorescent light produced by this film with the intensity of light produced by similar films of known thicknesses in response to the same amount of excitation energy. The preferred embodiment of the invention uses fiber optic probes in measuring the thicknesses of oil films on the operational components of machinery which are ordinarily obscured from view.

  17. Resonances and Tides in Natural Satellites Systems. (Breton Title: Ressonâncias e Marés em Sistemas de Satélites Naturais.) Resonancias y Mareas en Sistemas de Satélites Naturales

    NASA Astrophysics Data System (ADS)

    Callegari, Nelson, Jr.

    2006-12-01

    In this work we describe some aspects of the dynamics of the mean-motion resonances. Emphasis to the case of resonances between regular satellites of the giant planets will be given, even so some aspects of the physics of the resonances in extra-solar planetary systems are also briefly treated. The role of the resonances in satellites systems is discussed through examples, showing how certain resonances, and its relations with the tidal dissipation effects, can be the key of the explanation of some phenomena still not explained in the Solar System. Amongst some examples we highlight the problem of the resurfacing of Enceladus, the existence of active volcanoes in Io, and the possible existence of the subsurface ocean in Europe. This work has as objective the divulgation of some topics in Celestial Mechanics and Planetary Sciences for an undergraduate public in exact sciences, as Astronomy and Physics, and not their detailed description. Neste trabalho descrevemos alguns aspectos da dinâmica de ressonâncias de movimentos médios. Será dada ênfase maior ao caso de ressonâncias entre satélites regulares dos planetas gigantes, embora alguns aspectos da física das ressonâncias em sistemas planetários extra-solares também sejam discutidos brevemente. A importância do estudo de ressonâncias em sistemas de satélites é discutida mais detalhadamente através de exemplos, mostrando como certas ressonâncias e suas relações com efeitos de dissipação de maré podem ser a chave de parte da explicação de alguns fenômenos ainda não explicados no Sistema Solar. Dentre vários exemplos destacamos o problema da remodelagem da superfície do satélite Enceladus, a existência de vulcões ativos em Io, e a possível existência do oceano subterrâneo em Europa. Este trabalho tem como objetivo a divulgação de alguns tópicos de Mecânica Celeste e Planetologia para um público de nível de graduação em disciplinas na área de exatas, em especial Astronomia e F

  18. Directional spectral emissivity measurement system

    NASA Technical Reports Server (NTRS)

    Halyo, Nesim (Inventor); Pandey, Dhirendra K. (Inventor)

    1992-01-01

    Apparatus and process for determining the emissivity of a test specimen including an integrated sphere having two concentric walls with a coolant circulating therebetween, and disposed within a chamber which may be under ambient, vacuum or inert gas conditions. A reference sample is disposed within the sphere with a monochromatic light source in optical alignment therewith. A pyrometer is in optical alignment with the test sample for obtaining continuous test sample temperature measurements during a test. An arcuate slit port is provided through the spaced concentric walls of the integrating sphere with a movable monochromatic light source extending through and movable along the arcuate slit port. A detector system extends through the integrating sphere for continuously detecting an integrated signal indicative of all radiation within its field of view, as a function of the emissivity of the test specimen at various temperatures and various angle position of the monochromatic light source. A furnace for heating the test sample to approximately 3000 K. and control mechanism for transferring the heated sample from the furnace to the test sample port in the integrating sphere is also contained within the chamber.

  19. Thoughts on Seeing "El Sistema"

    ERIC Educational Resources Information Center

    Booth, Eric

    2009-01-01

    The FESNOJIV (the Spanish acronym for the State Foundation for the National System of Youth and Children's Orchestras), more commonly known as "El Sistema," teaches 300,000 of Venezuela's poorest children in the nationwide music learning program. Many begin attending the "nucleo" as early as age two or three, and the vast…

  20. Thoughts on Seeing "El Sistema"

    ERIC Educational Resources Information Center

    Booth, Eric

    2009-01-01

    The FESNOJIV (the Spanish acronym for the State Foundation for the National System of Youth and Children's Orchestras), more commonly known as "El Sistema," teaches 300,000 of Venezuela's poorest children in the nationwide music learning program. Many begin attending the "nucleo" as early as age two or three, and the vast…

  1. Phase measurement system using a dithered clock

    DOEpatents

    Fairley, C.R.; Patterson, S.R.

    1991-05-28

    A phase measurement system is disclosed which measures the phase shift between two signals by dithering a clock signal and averaging a plurality of measurements of the phase differences between the two signals. 8 figures.

  2. Mass properties measurement system: Dynamics and statics measurements

    NASA Technical Reports Server (NTRS)

    Doty, Keith L.

    1993-01-01

    This report presents and interprets experimental data obtained from the Mass Properties Measurement System (MPMS). Statics measurements yield the center-of-gravity of an unknown mass and dynamics measurements yield its inertia matrix. Observations of the MPMS performance has lead us to specific design criteria and an understanding of MPMS limitations.

  3. Advanced optical blade tip clearance measurement system

    NASA Technical Reports Server (NTRS)

    Ford, M. J.; Honeycutt, R. E.; Nordlund, R. E.; Robinson, W. W.

    1978-01-01

    An advanced electro-optical system was developed to measure single blade tip clearances and average blade tip clearances between a rotor and its gas path seal in an operating gas turbine engine. This system is applicable to fan, compressor, and turbine blade tip clearance measurement requirements, and the system probe is particularly suitable for operation in the extreme turbine environment. A study of optical properties of blade tips was conducted to establish measurement system application limitations. A series of laboratory tests was conducted to determine the measurement system's operational performance characteristics and to demonstrate system capability under simulated operating gas turbine environmental conditions. Operational and environmental performance test data are presented.

  4. System Measures Loads In Bolts

    NASA Technical Reports Server (NTRS)

    Allison, Sidney G.

    1994-01-01

    Improved technique for ultrasonic nondestructive measurement of loads in bolts involves use of pulsed phase-locked loop interferometer. Provides for correction of errors and for automatic readout of loads in bolts. Actual bolt load measured, using transducers rebonded after bolts tightened. Calibration block and thermometer added. Technique applicable to critical fasteners in aerospace applications, nuclear reactors, petroleum and other chemical processing plants, steel bridges, and other structures.

  5. Wireless Fluid Level Measuring System

    NASA Technical Reports Server (NTRS)

    Taylor, Bryant D. (Inventor); Woodard, Stanley E. (Inventor)

    2007-01-01

    A level-sensing probe positioned in a tank is divided into sections with each section including (i) a fluid-level capacitive sensor disposed along the length thereof, (ii) an inductor electrically coupled to the capacitive sensor, (iii) a sensor antenna positioned for inductive coupling to the inductor, and (iv) an electrical conductor coupled to the sensor antenna. An electrically non-conductive housing accessible from a position outside of the tank houses antennas arrayed in a pattern. Each antenna is electrically coupled to the electrical conductor from a corresponding one of the sections. A magnetic field response recorder has a measurement head with transceiving antennas arrayed therein to correspond to the pattern of the housing's antennas. When a measurement is to be taken, the measurement head is mechanically coupled to the housing so that each housing antenna is substantially aligned with a specific one of the transceiving antennas.

  6. Information Measures for Multisensor Systems

    DTIC Science & Technology

    2013-12-11

    permuted to generate spectra that were non- physical but preserved the entropy of the source spectra. Another 1000 spectra were constructed to mimic co...Research Laboratory (NRL) has yielded probabilistic models for spectral data that enable the computation of information measures such as entropy and...22308 Chemical sensing Information theory Spectral data Information entropy Information divergence Mass spectrometry Infrared spectroscopy Multisensor

  7. Interferometric Rayleigh Scattering Measurement System

    NASA Technical Reports Server (NTRS)

    Bivolaru, Daniel (Inventor); Danehy, Paul M. (Inventor); Lee, Joseph W. (Inventor)

    2008-01-01

    A method and apparatus for performing simultaneous multi-point measurements of multiple velocity components in a gas flow is described. Pulses of laser light are directed to a measurement region of unseeded gas to produce Rayleigh or Mie scattered light in a plurality of directions. The Rayleigh or Mie scattered light is collected from multiple directions and combined in a single collimated light beam. The Rayleigh or Mie scattered light is then mixed together with a reference laser light before it is passed through a single planar Fabry-Perot interferometer for spectral analysis. At the output of the interferometer, a high-sensitivity CCD camera images the interference fringe pattern. This pattern contains the spectral and spatial information from both the Rayleigh scattered light and the reference laser light. Interferogram processing software extracts and analyzes spectral profiles to determine the velocity components of the gas flow at multiple points in the measurement region. The Rayleigh light rejected by the interferometer is recirculated to increase the accuracy and the applicability of the method for measurements at high temperatures without requiring an increase in the laser energy.

  8. Breathing detection with a portable impedance measurement system: first measurements.

    PubMed

    Cordes, Axel; Foussier, Jerome; Leonhardt, Steffen

    2009-01-01

    For monitoring the health status of individuals, detection of breathing and heart activity is important. From an electrical point of view, it is known that breathing and heart activity change the electrical impedance distribution in the human body over the time due to ventilation (high impedance) and blood shifts (low impedance). Thus, it is possible to detect both important vital parameters by measuring the impedance of the thorax or the region around lung and heart. For some measurement scenarios it is also essential to detect these parameters contactless. For instance, monitoring bus drivers health could help to limit accidents, but directly connected systems limit the drivers free moving space. One measurement technology for measuring the impedance changes in the chest without cables is the magnetic impedance tomography (MIT). This article describes a portable measurement system we developed for this scenario that allows to measure breathing contactless. Furthermore, first measurements with five volunteers were performed and analyzed.

  9. Acoustic Doppler discharge-measurement system

    USGS Publications Warehouse

    Simpson, Michael R.; Oltmann, Richard N.; ,

    1990-01-01

    A discharge-measurement system that uses a vessel-mounted acoustic Doppler current profiler has been developed and tested by the U.S. Geological Survey. Discharge measurements using the system require a fraction of the time needed for conventional current-meter discharge measurements and do not require shore-based navigational aids or tag lines for positioning the vessel.

  10. Tree canopy radiance measurement system

    NASA Technical Reports Server (NTRS)

    Caldwell, William; Vanderbilt, V. C.

    1989-01-01

    A system is described for obtaining both an estimate of the spatial mean bidirectional reflectance factor (BRF) for a tree canopy (displaying a horizontally heterogeneous foliage distribution) and the statistical significance of that estimate. The system includes a manlift supporting a horizontal beam 7 m long on which are mounted four radiometers. These radiometers may be pointed, and radiance data acquired, in any of 11 view directions in the principal plane of the sun. A total of 80 data points, acquired in 3 min, were used to estimate the BRF of a walnut orchard 5 m tall and detect true differences of 12 percent of the mean approximately 90 percent of the time.

  11. Tree canopy radiance measurement system

    NASA Technical Reports Server (NTRS)

    Caldwell, William; Vanderbilt, V. C.

    1989-01-01

    A system is described for obtaining both an estimate of the spatial mean bidirectional reflectance factor (BRF) for a tree canopy (displaying a horizontally heterogeneous foliage distribution) and the statistical significance of that estimate. The system includes a manlift supporting a horizontal beam 7 m long on which are mounted four radiometers. These radiometers may be pointed, and radiance data acquired, in any of 11 view directions in the principal plane of the sun. A total of 80 data points, acquired in 3 min, were used to estimate the BRF of a walnut orchard 5 m tall and detect true differences of 12 percent of the mean approximately 90 percent of the time.

  12. Tree canopy radiance measurement system

    NASA Astrophysics Data System (ADS)

    Caldwell, William; Vanderbilt, V. C.

    1989-11-01

    A system is described for obtaining both an estimate of the spatial mean bidirectional reflectance factor (BRF) for a tree canopy (displaying a horizontally heterogeneous foliage distribution) and the statistical significance of that estimate. The system includes a manlift supporting a horizontal beam 7 m long on which are mounted four radiometers. These radiometers may be pointed, and radiance data acquired, in any of 11 view directions in the principal plane of the sun. A total of 80 data points, acquired in 3 min, were used to estimate the BRF of a walnut orchard 5 m tall and detect true differences of 12 percent of the mean approximately 90 percent of the time.

  13. Small satellite radiometric measurement system

    SciTech Connect

    Weber, P.G.

    1992-01-01

    A critical need for the US Global Change Research Program is to provide continuous, well-calibrated radiometric data for the earth's radiation budget. This paper describes a new, compact, relatively light-weight, adaptable radiometer which will provide both spectrally integrated measurements and data in selected spectral bands. The radiometer design is suitable for use on small satellites, aircraft, or remotely piloted aircraft (RPAs). An example of the implementation of this radiometer on a small satellite is given. Significant benefits derive from simultaneous measurements of specific narrow (in wavelength) spectral features; such data may be obtained by combining LARI with a compact spectrometer on the same platform. Well-chosen satellite orbits allow one to use data from other satellites (e.g. DMSP) to enhance the data product, or to provide superior coverage of specific locations. 23 refs.

  14. Small satellite radiometric measurement system

    SciTech Connect

    Weber, P.G.

    1992-01-01

    A critical need for the US Global Change Research Program is to provide continuous, well-calibrated radiometric data for the earth`s radiation budget. This paper describes a new, compact, relatively light-weight, adaptable radiometer which will provide both spectrally integrated measurements and data in selected spectral bands. The radiometer design is suitable for use on small satellites, aircraft, or remotely piloted aircraft (RPAs). An example of the implementation of this radiometer on a small satellite is given. Significant benefits derive from simultaneous measurements of specific narrow (in wavelength) spectral features; such data may be obtained by combining LARI with a compact spectrometer on the same platform. Well-chosen satellite orbits allow one to use data from other satellites (e.g. DMSP) to enhance the data product, or to provide superior coverage of specific locations. 23 refs.

  15. Bluetooth-based distributed measurement system

    NASA Astrophysics Data System (ADS)

    Tang, Baoping; Chen, Zhuo; Wei, Yuguo; Qin, Xiaofeng

    2007-07-01

    A novel distributed wireless measurement system, which is consisted of a base station, wireless intelligent sensors and relay nodes etc, is established by combining of Bluetooth-based wireless transmission, virtual instrument, intelligent sensor, and network. The intelligent sensors mounted on the equipments to be measured acquire various parameters and the Bluetooth relay nodes get the acquired data modulated and sent to the base station, where data analysis and processing are done so that the operational condition of the equipment can be evaluated. The establishment of the distributed measurement system is discussed with a measurement flow chart for the distributed measurement system based on Bluetooth technology, and the advantages and disadvantages of the system are analyzed at the end of the paper and the measurement system has successfully been used in Daqing oilfield, China for measurement of parameters, such as temperature, flow rate and oil pressure at an electromotor-pump unit.

  16. Automatic blood pressure measuring system (M092)

    NASA Technical Reports Server (NTRS)

    Nolte, R. W.

    1977-01-01

    The Blood Pressure Measuring System is described. It measures blood pressure by the noninvasive Korotkoff sound technique on a continual basis as physical stress is imposed during experiment M092, Lower Body Negative Pressure, and experiment M171, Metabolic Activity.

  17. Automatic blood pressure measuring system (M091)

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The Leg Volume Measuring System is used to measure leg calf girth changes that occur during exposure to lower body negative pressure as a result of pooling of blood and other fluids in the lower extremities.

  18. Automatic blood pressure measuring system (M092)

    NASA Technical Reports Server (NTRS)

    Nolte, R. W.

    1977-01-01

    The Blood Pressure Measuring System is described. It measures blood pressure by the noninvasive Korotkoff sound technique on a continual basis as physical stress is imposed during experiment M092, Lower Body Negative Pressure, and experiment M171, Metabolic Activity.

  19. Automatic blood pressure measuring system (M091)

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The Leg Volume Measuring System is used to measure leg calf girth changes that occur during exposure to lower body negative pressure as a result of pooling of blood and other fluids in the lower extremities.

  20. Miniaturization of flight deflection measurement system

    NASA Technical Reports Server (NTRS)

    Fodale, Robert (Inventor); Hampton, Herbert R. (Inventor)

    1990-01-01

    A flight deflection measurement system is disclosed including a hybrid microchip of a receiver/decoder. The hybrid microchip decoder is mounted piggy back on the miniaturized receiver and forms an integral unit therewith. The flight deflection measurement system employing the miniaturized receiver/decoder can be used in a wind tunnel. In particular, the miniaturized receiver/decoder can be employed in a spin measurement system due to its small size and can retain already established control surface actuation functions.

  1. Precision Antenna Measurement System (PAMS) Engineering Services

    DTIC Science & Technology

    1978-04-01

    Any variation of these variables are classified as errors. The first step is to divide the sources of error into two groups , namely system and...collecting the data fall into two groups . First, the system and bias errors are measured. These measurements are made with stationary signal sources...becomes available. The s.econd group of measurements will concern themselves with the dynamic errors. This group of measurements can be accomplished

  2. Particle measurement systems and methods

    DOEpatents

    Steele, Paul T [Livermore, CA

    2011-10-04

    A system according to one embodiment includes a light source for generating light fringes; a sampling mechanism for directing a particle through the light fringes; and at least one light detector for detecting light scattered by the particle as the particle passes through the light fringes. A method according to one embodiment includes generating light fringes using a light source; directing a particle through the light fringes; and detecting light scattered by the particle as the particle passes through the light fringes using at least one light detector.

  3. 600-GHz Electronically Tunable Vector Measurement System

    NASA Technical Reports Server (NTRS)

    Dengler, Robert; Maiwald, Frank; Siegel, Peter

    2007-01-01

    A compact, high-dynamic-range, electronically tunable vector measurement system that operates in the frequency range from approximately 560 to approximately 635 GHz has been developed as a prototype of vector measurement systems that would be suitable for use in nearly-real-time active submillimeter-wave imaging. As used here, 'vector measurement system" signifies an instrumentation system that applies a radio-frequency (RF) excitation to an object of interest and measures the resulting amplitude and phase response, relative to either the applied excitatory signal or another reference signal related in a known way to applied excitatory signal.

  4. Development of a surface panel measurement system

    NASA Technical Reports Server (NTRS)

    Jones, D. L.

    1981-01-01

    Reflector measurement systems are studied in support of the reshaping of the 34 meter antenna at Goldstone. The requirements for measurement systems are presented. A survey is made of the surface errors of existing antennas. Reflector measurement systems are divided into three categories and representative examples of each category are illustrated and discussed. Parametric error analyses are made of selected optical systems. The existing measurement method using a theodolite at the vertex is retained. A method using a theodolite on the RF cone is a possible variant.

  5. The LEDA beam-position measurement system

    SciTech Connect

    Rose, C.R.; Gilpatrick, J.D.; Stettler, M.W.

    1997-08-01

    This paper describes the beam-position measurement system being developed for the Low Energy Demonstration Accelerator (LEDA) and the Accelerator Production of Tritium (APT) projects at Los Alamos National Laboratory. The system consists of a beam-position monitor (BPM) probe, cabling, down-converter module, position/intensity module, on-line error-correction system, and the necessary control system interfaces. The modules are built on the VXI-interface standard and are capable of duplex data transfer with the control system. Some of the key, system parameters are: position-measurement bandwidth of at least 180 kHz, the ability to measure beam intensity, a beam-position measurement accuracy of less than 1.25 percent of the bore radius, a beam-current dynamic range of 46 dB, a total system dynamic range in excess of 75 dB, and built-in on-line digital-system-error correction.

  6. Optimetric system facilitates colorimetric and fluorometric measurements

    NASA Technical Reports Server (NTRS)

    Haley, F. C.

    1968-01-01

    Compact, unitary optimetric systems uses a single device for colorimetric, fluorometric and spectral absorption measurements. The basic element of the unitary systems is a test cell containing filter elements with uniquely fabricated lenses.

  7. A shielded measurement system for irradiated nuclear fuel measurements

    SciTech Connect

    Mosby, W.R.; Aumeier, S.E.; Klann, R.T.

    1999-07-01

    The US Department of Energy (DOE) is driving a transition toward dry storage of irradiated nuclear fuel (INF), toward characterization of INF for final disposition, and toward resumption of measurement-based material control and accountability (MC and A) efforts for INF. For these reasons, the ability to efficiently acquire radiological measurements of INF in a dry environment is important. The DOE has recently developed a guidance document proposing MC and A requirements for INF. The intent of this document is to encourage the direct measurement of INF on inventory within DOE. The guidance document reinforces and clarifies existing material safeguards requirements as they pertain to INF. Validation of nuclear material contents of non-self-protecting INF must be accomplished by direct measurement, application of validated burnup codes using qualified initial fissile content, burnup data, and age or by other valid means. The fuel units must remain intact with readable identification numbers. INF may be subject to periodic inventories with visual item accountability checks. Quantitative measurements may provide greater assurance of the integrity of INF inventories at a lower cost and with less personnel exposure than visual item accountability checks. Currently, several different approaches are used to measure the radiological attributes of INF. Although these systems are useful for a wide variety of applications, there is currently no relatively inexpensive measurement system that is readily deployable for INF measurements for materials located in dry storage. The authors present the conceptual design of a shielded measurement system (SMS) that could be used for this purpose. The SMS consists of a shielded enclosure designed to house a collection of measurement systems to allow measurements on spent fuel outside of a hot cell. The phase 1 SMS will contain {sup 3}He detectors and ionization chambers to allow for gross neutron and gamma-ray measurements. The phase 2

  8. GPS synchronized power system phase angle measurements

    NASA Astrophysics Data System (ADS)

    Wilson, Robert E.; Sterlina, Patrick S.

    1994-09-01

    This paper discusses the use of Global Positioning System (GPS) synchronized equipment for the measurement and analysis of key power system quantities. Two GPS synchronized phasor measurement units (PMU) were installed before testing. It was indicated that PMUs recorded the dynamic response of the power system phase angles when the northern California power grid was excited by the artificial short circuits. Power system planning engineers perform detailed computer generated simulations of the dynamic response of the power system to naturally occurring short circuits. The computer simulations use models of transmission lines, transformers, circuit breakers, and other high voltage components. This work will compare computer simulations of the same event with field measurement.

  9. A new thoron atmosphere reference measurement system.

    PubMed

    Sabot, B; Pierre, S; Michielsen, N; Bondiguel, S; Cassette, P

    2016-03-01

    A new thoron reference ((220)Rn) in air measurement system is developed at the LNE-LNHB with the collaboration of the IRSN. This measurement system is based on a reference volume with an alpha detector which is able to directly measure thoron and its decay products at atmospheric pressure. In order to improve the spectrum quality of the thoron progenies, we have applied an electric field to catch the decay products on the detector surface. The developed system is a portative device which can be used to measure reference thoron atmosphere such as the BACCARA chamber at IRSN (Picolo et al., 1999). As this system also allows the measurement of radon ((222)Rn) in air, it was validated using the radon primary standards made at the LNE-LNHB. This thoron measurement system will be used, at IRSN, as a reference instrument in order to calibrate the thoron activity concentration in the BACCARA facility. Copyright © 2015. Published by Elsevier Ltd.

  10. Measurement of SIFT operating system overhead

    NASA Technical Reports Server (NTRS)

    Palumbo, D. L.; Butler, R. W.

    1985-01-01

    The overhead of the software implemented fault tolerance (SIFT) operating system was measured. Several versions of the operating system evolved. Each version represents different strategies employed to improve the measured performance. Three of these versions are analyzed. The internal data structures of the operating systems are discussed. The overhead of the SIFT operating system was found to be of two types: vote overhead and executive task overhead. Both types of overhead were found to be significant in all versions of the system. Improvements substantially reduced this overhead; even with these improvements, the operating system consumed well over 50% of the available processing time.

  11. Multi-interferometric displacement measurement system with variable measurement mirrors.

    PubMed

    Chang, Chung-Ping; Tung, Pi-Cheng; Shyu, Lih-Horng; Wang, Yung-Cheng; Manske, Eberhard

    2013-06-10

    Laser interferometers have been widely implemented for the displacement sensing and positioning calibration of the precision mechanical industry, due to their excellent measuring features and direct traceability to the dimensional definition. Currently some kinds of modified Fabry-Perot interferometers with a planar mirror or a corner cube prism as the measurement mirror have been proposed. Each optical structure of both models has the individual particularity and performance for measuring applications. In this investigation, a multi-interferometric displacement system has been proposed whose measurement mirror can be quickly and conveniently altered with a planar mirror or a corner cube reflector depending on the measuring demand. Some experimental results and analyses about the interpolation error and displacement measurements with both reflectors have been demonstrated. According to the results, suggestions about the choice of a measuring reflector and interpolation model have been presented. With the measuring verifications, the developed system with a maximum standard deviation less than 0.2081 μm in measuring range of 300 mm would be a compact and robust tool for sensing or calibrating the linear displacement of mechanical equipment.

  12. Implementing a Global Performance Measurement System.

    ERIC Educational Resources Information Center

    Tesoro, Ferdinand; Tootson, Jack

    2001-01-01

    The systematic four-step process introduced in this article lays the basic groundwork in helping an organization link all its programs and initiatives to its strategic goals. Discusses the definition and purpose of performance measurement; elements of a global performance system; and building a global performance measurement system. (AEF)

  13. Tank waste remediation system compensatory measure removal

    SciTech Connect

    MILLIKEN, N.J.

    1999-05-18

    In support of Fiscal Year 1998 Performance Agreement TWR1.4.3, ''Replace Compensatory Measures,'' the Tank Waste Remediation System is documenting the completion of field modifications supporting the removal of the temporary exemptions from the approved Tank Waste Remediation System Technical Safety Requirements (TSRs), HNF-SD-WM-TSR-006. These temporary exemptions or compensatory measures expire September 30, 1998.

  14. Compressibility measurement of fluid-system ullage

    NASA Technical Reports Server (NTRS)

    Dzienis, D. A.; See, E. C.

    1977-01-01

    Portable self-contained instrument measures volume of free gas or air trapped in closed fluid systems, such as lubricating-oil lines or hydraulic brakes. In response to measurement readings, operator may use device to accurately add or withdraw fluid to or from system.

  15. Designing Digital Control Systems With Averaged Measurements

    NASA Technical Reports Server (NTRS)

    Polites, Michael E.; Beale, Guy O.

    1990-01-01

    Rational criteria represent improvement over "cut-and-try" approach. Recent development in theory of control systems yields improvements in mathematical modeling and design of digital feedback controllers using time-averaged measurements. By using one of new formulations for systems with time-averaged measurements, designer takes averaging effect into account when modeling plant, eliminating need to iterate design and simulation phases.

  16. A measuring system for surface roughness parameters

    NASA Astrophysics Data System (ADS)

    Han, Jinhong; Wang, Yunkai; Zhang, Xianfeng

    2006-11-01

    We designed a measurement and control system which can measure the surface roughness parameters with a Single Chip Micyoco (SCM) as its kernel. It uses an inductive transducer to pick up the data. The instrumental structure and the working principle are also introduced in this paper. The integrated hardware and software systems have been designed and improved. The prototype model was calibrated and the instrumental precision was analysed according to the measured data. In this system the surface roughness parameters can automatically be measured and controlled, such as data processing, determination of the reference line, disposal of the surface profile informations, display and print of the results etc.

  17. Performance measurement for information systems: Industry perspectives

    NASA Technical Reports Server (NTRS)

    Bishop, Peter C.; Yoes, Cissy; Hamilton, Kay

    1992-01-01

    Performance measurement has become a focal topic for information systems (IS) organizations. Historically, IS performance measures have dealt with the efficiency of the data processing function. Today, the function of most IS organizations goes beyond simple data processing. To understand how IS organizations have developed meaningful performance measures that reflect their objectives and activities, industry perspectives on IS performance measurement was studied. The objectives of the study were to understand the state of the practice in IS performance techniques for IS performance measurement; to gather approaches and measures of actual performance measures used in industry; and to report patterns, trends, and lessons learned about performance measurement to NASA/JSC. Examples of how some of the most forward looking companies are shaping their IS processes through measurement is provided. Thoughts on the presence of a life-cycle to performance measures development and a suggested taxonomy for performance measurements are included in the appendices.

  18. Direct strike lightning measurement system. [for aircraft

    NASA Technical Reports Server (NTRS)

    Thomas, M. E.

    1981-01-01

    A research data system developed for in-flight measurement of direct and nearby lightning-strike characteristics is described. The measurement system consists of a wide-band analog recorder which records the continuous lightning scenario and fast sample-rate digital transient recorders with augmented memory capacity for increased time resolution of specific times of interest. Electromagnetic sensors with bandwidths exceeding 100 MHz are used which respond to rates of change of the quantities being measured. Data system immunity from electromagnetic interference is accomplished by the use of a dynamotor for power isolation, shielded system enclosure and fiber-optic data links.

  19. Measuring the Effectiveness of Information Systems

    DTIC Science & Technology

    1991-06-01

    Baronas and Louis, 1988) The problem for a user is deciding which IS effectiveness measure to apply to a given system. In Chapter II, individual measures...throughout its implementation. An empirical study conducted by Baronas and Louis (1988) concluded that users’ involvement in system installation is...user’s satisfaction with the system. Baronas and Louis (1988) conducted an empirical study involving ninety-two payroll and personnel employees from 35

  20. Assessing the capabilities of patternshop measurement systems

    SciTech Connect

    Peters, F.E.; Voigt, R.C.

    1995-12-01

    Casting customers continue to demand tighter dimensional tolerances for casting features. The foundry then places demands on the patternshop to produce more accurate patterns. Control of all sources of dimensional variability, including measurement system variability in the foundry and patternshop, is important to insure casting accuracy. Sources of dimensional casting errors will be reviewed, focusing on the importance of accurate patterns. The foundry and patternshop together must work within the tolerance limits established by the customer. In light of contemporary pattern tolerances, the patternshop must review its current measurement methods. The measurement instrument must have sufficient resolution to detect part variability. In addition, the measurement equipment must be used consistently by all patternmakers to insure adequacy of the measurement system. Without these precautions, measurement error can significantly contribute to overall pattern variability. Simple robust methods to check the adequacy of pattern measurement systems are presented. These tests will determine the variability that is contributed by the measurement equipment and by the operators. Steps to control measurement variability once it has been identified are also provided. Measurement system errors for various types of measurement equipment are compared to the allowable pattern tolerances, that are established together by the foundry and patternshop.

  1. Turbine gas temperature measurement and control system

    NASA Technical Reports Server (NTRS)

    Webb, W. L.

    1973-01-01

    A fluidic Turbine Inlet Gas Temperature (TIGIT) Measurement and Control System was developed for use on a Pratt and Whitney Aircraft J58 engine. Based on engine operating requirements, criteria for high temperature materials selection, system design, and system performance were established. To minimize development and operational risk, the TIGT control system was designed to interface with an existing Exhaust Gas Temperature (EGT) Trim System and thereby modulate steady-state fuel flow to maintain a desired TIGT level. Extensive component and system testing was conducted including heated (2300F) vibration tests for the fluidic sensor and gas sampling probe, temperature and vibration tests on the system electronics, burner rig testing of the TIGT measurement system, and in excess of 100 hours of system testing on a J58 engine. (Modified author abstract)

  2. The Fork+ burnup measurement system: Design and first measurement campaign

    SciTech Connect

    Olson, C.E.; Bronowski, D.R.; McMurtry, W.; Ewing, R.; Jordan, R.; Rivard, D.

    1998-12-31

    Previous work with the original Fork detector showed that burnup as determined by reactor records could be accurately allocated to spent nuclear fuel assemblies. The original Fork detector, designed by Los Alamos National Laboratory, used an ion chamber to measure gross gamma count and a fission chamber to measure neutrons from an activation source, {sup 244}Cm. In its review of the draft Topical Report on Burnup Credit, the US Nuclear Regulatory Commission indicated it felt uncomfortable with a measurement system that depended on reactor records for calibration. The Fork+ system was developed at Sandia National Laboratories under the sponsorship of the Electric Power Research Institute with the aim of providing this independent measurement capability. The initial Fork+ prototype was used in a measurement campaign at the Maine Yankee reactor. The campaign confirmed the applicability of the sensor approach in the Fork+ system and the efficiency of the hand-portable Fork+ prototype in making fuel assembly measurements. It also indicated potential design modifications that will be necessary before the Fork+ can be used effectively on high-burnup spent fuel.

  3. Measuring Fiscal Capacity of School Systems.

    ERIC Educational Resources Information Center

    Green, Harry A.

    Ways of measuring the fiscal capacity of school systems are examined in this paper, which presents a representative tax system model. Fiscal capacity is influenced by factors other than tax base size; the "ideal" model should address adjustments for variations in cost across communities and school systems. The first section examines the…

  4. Entropy Measurement for Biometric Verification Systems.

    PubMed

    Lim, Meng-Hui; Yuen, Pong C

    2016-05-01

    Biometric verification systems are designed to accept multiple similar biometric measurements per user due to inherent intrauser variations in the biometric data. This is important to preserve reasonable acceptance rate of genuine queries and the overall feasibility of the recognition system. However, such acceptance of multiple similar measurements decreases the imposter's difficulty of obtaining a system-acceptable measurement, thus resulting in a degraded security level. This deteriorated security needs to be measurable to provide truthful security assurance to the users. Entropy is a standard measure of security. However, the entropy formula is applicable only when there is a single acceptable possibility. In this paper, we develop an entropy-measuring model for biometric systems that accepts multiple similar measurements per user. Based on the idea of guessing entropy, the proposed model quantifies biometric system security in terms of adversarial guessing effort for two practical attacks. Excellent agreement between analytic and experimental simulation-based measurement results on a synthetic and a benchmark face dataset justify the correctness of our model and thus the feasibility of the proposed entropy-measuring approach.

  5. Radiation beam calorimetric power measurement system

    DOEpatents

    Baker, John; Collins, Leland F.; Kuklo, Thomas C.; Micali, James V.

    1992-01-01

    A radiation beam calorimetric power measurement system for measuring the average power of a beam such as a laser beam, including a calorimeter configured to operate over a wide range of coolant flow rates and being cooled by continuously flowing coolant for absorbing light from a laser beam to convert the laser beam energy into heat. The system further includes a flow meter for measuring the coolant flow in the calorimeter and a pair of thermistors for measuring the temperature difference between the coolant inputs and outputs to the calorimeter. The system also includes a microprocessor for processing the measured coolant flow rate and the measured temperature difference to determine the average power of the laser beam.

  6. Detection system for ocular refractive error measurement.

    PubMed

    Ventura, L; de Faria e Sousa, S J; de Castro, J C

    1998-05-01

    An automatic and objective system for measuring ocular refractive errors (myopia, hyperopia and astigmatism) was developed. The system consists of projecting a light target (a ring), using a diode laser (lambda = 850 nm), at the fundus of the patient's eye. The light beams scattered from the retina are submitted to an optical system and are analysed with regard to their vergence by a CCD detector (matrix). This system uses the same basic principle for the projection of beams into the tested eye as some commercial refractors, but it is innovative regarding the ring-shaped measuring target for the projection system and the detection system where a matrix detector provides a wider range of measurement and a less complex system for the optical alignment. Also a dedicated electronic circuit was not necessary for treating the electronic signals from the detector (as the usual refractors do); instead a commercial frame grabber was used and software based on the heuristic search technique was developed. All the guiding equations that describe the system as well as the image processing procedure are presented in detail. Measurements in model eyes and in human eyes are in good agreement with retinoscopic measurements and they are also as precise as these kinds of measurements require (0.125D and 5 degrees).

  7. Social Responsibility and Community Development: Lessons from the Sistema de Aprendizaje Tutorial in Honduras

    ERIC Educational Resources Information Center

    Honeyman, Catherine A.

    2010-01-01

    This article extends understanding of the connections between education, social capital, and development through a mixed-methods case study of the Sistema de Aprendizaje Tutorial, or SAT, an innovative secondary-level education system. The quantitative dimension of the research used survey measures of social responsibility to compare 93 SAT…

  8. Social Responsibility and Community Development: Lessons from the Sistema de Aprendizaje Tutorial in Honduras

    ERIC Educational Resources Information Center

    Honeyman, Catherine A.

    2010-01-01

    This article extends understanding of the connections between education, social capital, and development through a mixed-methods case study of the Sistema de Aprendizaje Tutorial, or SAT, an innovative secondary-level education system. The quantitative dimension of the research used survey measures of social responsibility to compare 93 SAT…

  9. Temperature measurement systems in wearable electronics

    NASA Astrophysics Data System (ADS)

    Walczak, S.; Gołebiowski, J.

    2014-08-01

    The aim of this paper is to present the concept of temperature measurement system, adapted to wearable electronics applications. Temperature is one of the most commonly monitored factor in smart textiles, especially in sportswear, medical and rescue products. Depending on the application, measured temperature could be used as an initial value of alert, heating, lifesaving or analysis system. The concept of the temperature measurement multi-point system, which consists of flexible screen-printed resistive sensors, placed on the T-shirt connected with the central unit and the power supply is elaborated in the paper.

  10. Analysis of measurement system as the mechatronics system

    NASA Astrophysics Data System (ADS)

    Giniotis, V.; Grattan, K. T. V.; Rybokas, M.; Bručas, D.

    2010-07-01

    The paper deals with the mechatronic arrangement for angle measuring system application. The objects to be measured are the circular raster scales, rotary encoders and coded scales. The task of the measuring system is to determine the bias of angle measuring standard as the circular scale and to use the results for the error correction and accuracy improvement of metal cutting machines, coordinate measuring machines, robots, etc. The technical solutions are given with the application of active materials for smart piezoactuators implemented into the several positions of angular measuring equipment. Mechatronic measuring system is analysed as complex integrated system and some of its elements can be used as separate units. All these functional elements are described and commented in the paper with the diagrams and graphs of errors and examples of microdisplacement devices using the mechatronic elements.

  11. Three-component laser anemometer measurement systems

    NASA Technical Reports Server (NTRS)

    Goldman, Louis J.

    1991-01-01

    A brief overview of the different laser anemometer (LA) optical designs available is presented. Then, the LA techniques that can be used to design a three-component measurement system for annular geometries are described. Some of the facility design considerations unique to these LA systems are also addressed. Following this, the facilities and the LA systems that were used to successfully measure the three components of velocity in the blading of annular-flow machines are reviewed. Finally, possible LA system enhancements and future research directions are presented.

  12. Navigational and Environmental Measurement System (NEMS)

    NASA Technical Reports Server (NTRS)

    Clem, T. D.

    1988-01-01

    The NEMS concept and design were initiated from the need to measure and record positional and environmental information during aircraft flights of developmental science research instrumentation. The unit was designed as a stand-alone system which could serve the needs of instruments whose developmental nature did not justify the cost and complexity of including these measurements within the instrument data system. Initially, the system was comprised of a Loran-C receiver and a portable IBM compatible computer recording position and time. Later, the system was interfaced with the Wallops aircraft inertial navigation system (INS), and various other sensors were supplied and shared by the Goddard science users. Real-time position mapping on video monitors was added for investigator's use and information. In 1987, the use of a Global Positioning System (GPS) receiver was included in some missions. A total configuration of the system and the various sensors which can be incorporated are shown.

  13. Automatic system for ionization chamber current measurements.

    PubMed

    Brancaccio, Franco; Dias, Mauro S; Koskinas, Marina F

    2004-12-01

    The present work describes an automatic system developed for current integration measurements at the Laboratório de Metrologia Nuclear of Instituto de Pesquisas Energéticas e Nucleares. This system includes software (graphic user interface and control) and a module connected to a microcomputer, by means of a commercial data acquisition card. Measurements were performed in order to check the performance and for validating the proposed design.

  14. Measurement System Characterization in the Presence of Measurement Errors

    NASA Technical Reports Server (NTRS)

    Commo, Sean A.

    2012-01-01

    In the calibration of a measurement system, data are collected in order to estimate a mathematical model between one or more factors of interest and a response. Ordinary least squares is a method employed to estimate the regression coefficients in the model. The method assumes that the factors are known without error; yet, it is implicitly known that the factors contain some uncertainty. In the literature, this uncertainty is known as measurement error. The measurement error affects both the estimates of the model coefficients and the prediction, or residual, errors. There are some methods, such as orthogonal least squares, that are employed in situations where measurement errors exist, but these methods do not directly incorporate the magnitude of the measurement errors. This research proposes a new method, known as modified least squares, that combines the principles of least squares with knowledge about the measurement errors. This knowledge is expressed in terms of the variance ratio - the ratio of response error variance to measurement error variance.

  15. Magnetic Field Response Measurement Acquisition System

    NASA Technical Reports Server (NTRS)

    Woodard, Stanley E.; Taylor, Bryant D.; Shams, Qamar A.; Fox, Robert L.

    2005-01-01

    A measurement acquisition method that alleviates many shortcomings of traditional measurement systems is presented in this paper. The shortcomings are a finite number of measurement channels, weight penalty associated with measurements, electrical arcing, wire degradations due to wear or chemical decay and the logistics needed to add new sensors. The key to this method is the use of sensors designed as passive inductor-capacitor circuits that produce magnetic field responses. The response attributes correspond to states of physical properties for which the sensors measure. A radio frequency antenna produces a time-varying magnetic field used to power the sensor and receive the magnetic field response of the sensor. An interrogation system for discerning changes in the sensor response is presented herein. Multiple sensors can be interrogated using this method. The method eliminates the need for a data acquisition channel dedicated to each sensor. Methods of developing magnetic field response sensors and the influence of key parameters on measurement acquisition are discussed.

  16. Distance and Cable Length Measurement System

    PubMed Central

    Hernández, Sergio Elias; Acosta, Leopoldo; Toledo, Jonay

    2009-01-01

    A simple, economic and successful design for distance and cable length detection is presented. The measurement system is based on the continuous repetition of a pulse that endlessly travels along the distance to be detected. There is a pulse repeater at both ends of the distance or cable to be measured. The endless repetition of the pulse generates a frequency that varies almost inversely with the distance to be measured. The resolution and distance or cable length range could be adjusted by varying the repetition time delay introduced at both ends and the measurement time. With this design a distance can be measured with centimeter resolution using electronic system with microsecond resolution, simplifying classical time of flight designs which require electronics with picosecond resolution. This design was also applied to position measurement. PMID:22303169

  17. Measuring fractal dimension of metro systems

    NASA Astrophysics Data System (ADS)

    Deng, S.; Li, W.; Gu, J.; Zhu, Y.; Zhao, L.; Han, J.

    2015-04-01

    We discuss cluster growing method and box-covering method as well as their connection to fractal geometry. Our measurements show that for small network systems, box-covering method gives a better scaling relation. We then measure both unweighted and weighted metro networks with optimal box-covering method.

  18. Ultrasonic System Measures Elastic Properties Of Composites

    NASA Technical Reports Server (NTRS)

    Bar-Cohen, Yoseph; Mal, Ajit K.

    1993-01-01

    Measurements with leaky Lamb waves yield data on properties and defects of panels. System nondestructively measures elastic properties of, and defects in, panel of laminated fiber/matrix material. Ultrasonic transducers operating in pitch/catch mode excite and detect leaky Lamb waves in specimen. Elastic properties of specimen and defects within it characterized from dispersion curves of Lamb waves.

  19. Acoustic systems for the measurement of streamflow

    USGS Publications Warehouse

    Laenen, Antonius; Smith, Winchell

    1983-01-01

    The acoustic velocity meter (AVM), also referred to as an ultrasonic flowmeter, has been an operational tool for the measurement of streamflow since 1965. Very little information is available concerning AVM operation, performance, and limitations. The purpose of this report is to consolidate information in such a manner as to provide a better understanding about the application of this instrumentation to streamflow measurement. AVM instrumentation is highly accurate and nonmechanical. Most commercial AVM systems that measure streamflow use the time-of-travel method to determine a velocity between two points. The systems operate on the principle that point-to-point upstream travel-time of sound is longer than the downstream travel-time, and this difference can be monitored and measured accurately by electronics. AVM equipment has no practical upper limit of measurable velocity if sonic transducers are securely placed and adequately protected. AVM systems used in streamflow measurement generally operate with a resolution of ?0.01 meter per second but this is dependent on system frequency, path length, and signal attenuation. In some applications the performance of AVM equipment may be degraded by multipath interference, signal bending, signal attenuation, and variable streamline orientation. Presently used minicomputer systems, although expensive to purchase and maintain, perform well. Increased use of AVM systems probably will be realized as smaller, less expensive, and more conveniently operable microprocessor-based systems become readily available. Available AVM equipment should be capable of flow measurement in a wide variety of situations heretofore untried. New signal-detection techniques and communication linkages can provide additional flexibility to the systems so that operation is possible in more river and estuary situations.

  20. Heterodyne laser instantaneous frequency measurement system

    DOEpatents

    Wyeth, Richard W.; Johnson, Michael A.; Globig, Michael A.

    1990-01-01

    A heterodyne laser instantaneous frequency measurement system is disclosed. The system utilizes heterodyning of a pulsed laser beam with a continuous wave laser beam to form a beat signal. The beat signal is processed by a controller or computer which determines both the average frequency of the laser pulse and any changes or chirp of the frequency during the pulse.

  1. Heterodyne laser instantaneous frequency measurement system

    DOEpatents

    Wyeth, Richard W.; Johnson, Michael A.; Globig, Michael A.

    1989-01-01

    A heterodyne laser instantaneous frequency measurement system is disclosed. The system utilizes heterodyning of a pulsed laser beam with a continuous wave laser beam to form a beat signal. The beat signal is processed by a controller or computer which determines both the average frequency of the laser pulse and any changes or chirp of th frequency during the pulse.

  2. Self-Aligning Optical Measurement Systems

    NASA Technical Reports Server (NTRS)

    Decker, Arthur J.

    1992-01-01

    The paper discusses how to teach a system of neural networks to respond to the alignment clues used by a human operator in performing routine, initial alignments. A paradigm is proposed for automating the alignment of the components of optical measurement systems. The paradigm which was tested on a spatial filter has proved to be successful for optical alignment.

  3. Measuring Performance with Library Automated Systems.

    ERIC Educational Resources Information Center

    OFarrell, John P.

    2000-01-01

    Investigates the capability of three library automated systems to generate some of the datasets necessary to form the ISO (International Standards Organization) standard on performance measurement within libraries, based on research in Liverpool John Moores University (United Kingdom). Concludes that the systems are weak in generating the…

  4. Time measurment system at the SSC

    SciTech Connect

    Arai, Yasuo

    1989-04-01

    A proposal of time measurement system at the SSC experiment is described. An example of a possible scheme for central tracking chambers is shown. Designs of a preamp/shaper/discri chip and a time digitizer chip are described. A method to distribute system clock and power/cooling problems are also discussed.

  5. Measuring Performance with Library Automated Systems.

    ERIC Educational Resources Information Center

    OFarrell, John P.

    2000-01-01

    Investigates the capability of three library automated systems to generate some of the datasets necessary to form the ISO (International Standards Organization) standard on performance measurement within libraries, based on research in Liverpool John Moores University (United Kingdom). Concludes that the systems are weak in generating the…

  6. Measurement of insulation layers using DTS system

    NASA Astrophysics Data System (ADS)

    Hruby, David; Kajnar, Tomas; Koudelka, Petr; Latal, Jan; Hurta, Jan; Kepak, Stanislav; Jaros, Jakub; Vasinek, Vladimir

    2015-01-01

    Fiber optic distributed temperature sensing systems (DTS) are based on the principle of reflectometer and allow us to measure the temperature along the optical fiber. Optical fiber in these systems is used as a temperature sensor which can measure up to thousands of points simultaneously. DTS sensors use nonlinear phenomenon known as Raman scattering for temperature measurement. The advantages of this system include immunity to electromagnetic radiation, low cost of optical fiber, the possibility of measurement to a distance of 10 km and safe use in flammable or corrosive environments. The small size of optical fiber allows using in applications where the dimensions of the other sensors were problematic. A typical example of the DTS application is the fire detection in tunnels and buildings at risk, detection of water leaks on dikes and dams or monitoring of temperature in mine shafts. This article deals with the measurement of temperature transmission over various insulation layers using the DTS system. One of the problems of temperature transmission is that most of the sensors cannot measure the entire temperature profile but only allows a point measurement. This problem is solved by DTS systems with optical fibers. Optical fiber, due to its small size, can be applied among various insulation layers that were formed by rock wool. Three sensory layers formed by rings of multimode optical tightbuffered fiber with 50/125 micron core/cladding dimension were applied. The layers were linked together allowing a direct comparison of measured temperature. Rows of rings were placed on the margins and one was in the middle. Individual rings were linked together into the horizontal lines. Thus we were able to cover the whole surface of the insulation layers. Measurement was carried out in a closed air-conditioned room for 37 hours. Graphs with the progress of temperature at time and place were compiled from the measured data.

  7. Telerobotic system performance measurement - Motivation and methods

    NASA Technical Reports Server (NTRS)

    Kondraske, George V.; Khoury, George J.

    1992-01-01

    A systems performance-based strategy for modeling and conducting experiments relevant to the design and performance characterization of telerobotic systems is described. A developmental testbed consisting of a distributed telerobotics network and initial efforts to implement the strategy described is presented. Consideration is given to the general systems performance theory (GSPT) to tackle human performance problems as a basis for: measurement of overall telerobotic system (TRS) performance; task decomposition; development of a generic TRS model; and the characterization of performance of subsystems comprising the generic model. GSPT employs a resource construct to model performance and resource economic principles to govern the interface of systems to tasks. It provides a comprehensive modeling/measurement strategy applicable to complex systems including both human and artificial components. Application is presented within the framework of a distributed telerobotics network as a testbed. Insight into the design of test protocols which elicit application-independent data is described.

  8. Coal face measurement system for underground use

    NASA Technical Reports Server (NTRS)

    1981-01-01

    A measurement system was developed for the Eickhoff longwall shearer to determine the contour of the coal face as it mines coal. Contour data are obtained by an indirect measurement technique based on evaluating the motion of the shearer during mining. Starting from a known location, points along the coal face are established through a knowledge of the machines' positions and yaw movements as it moves past the coal face. The hardware and system operation procedures are described. The tests of system performance and their results are reported.

  9. Systems and methods for measuring component matching

    NASA Technical Reports Server (NTRS)

    Courter, Kelly J. (Inventor); Slenk, Joel E. (Inventor)

    2006-01-01

    Systems and methods for measuring a contour match between adjacent components are disclosed. In one embodiment, at least two pressure sensors are located between adjacent components. Each pressure sensor is adapted to obtain a pressure measurement at a location a predetermined distance away from the other pressure sensors, and to output a pressure measurement for each sensor location. An output device is adapted to receive the pressure measurements from at least two pressure sensors and display the pressure measurements. In one aspect, the pressure sensors include flexible thin film pressure sensors. In accordance with other aspects of the invention, a method is provided for measuring a contour match between two interfacing components including measuring at least one pressure applied to at least one sensor between the interfacing components.

  10. Statistically Comparing Three Optical Cd Measurement Systems

    NASA Astrophysics Data System (ADS)

    Acree, David A.; Lee, Chen-Show

    1989-07-01

    The rapid technological change in the VLSI industry has resulted in a constant upgrading of measurement equipment. One question to be asked is whether the upgrades recommended really improve the measurement system. Precise measurement equipment is one of the most important components in the next generation of VLSI technology. A systematic approach to measurement equipment upgrades in one micron technology can save much grief and remove uncertainty. In order to compare three optical CD measurement systems simultaneously, a statistically designed systematic approach was employed. The major contributors of variation were identified and quantified. The precision of each optical CD system was then compared. Findings from the study showed the upgraded system reduced variability associated with machine repeatability by a third, but only reduced overall measurement variation by a tenth. The same methods used here can apply in most cases where one piece of equipment is evaluated or several are compared. Vendor claims can be easily tested through the approach described. Reductions in measurement variation associated with an upgrade can be actually quantified allowing management to weigh benefits against costs.

  11. Telerobotic system performance measurement: motivation and methods

    NASA Astrophysics Data System (ADS)

    Kondraske, George V.; Khoury, George J.

    1992-11-01

    Telerobotic systems (TRSs) and shared teleautonomous systems result from the integration of multiple sophisticated modules. Procedures used in systems integration design decision-making of such systems are frequently ad hoc compared to more quantitative and systematic methods employed elsewhere in engineering. Experimental findings associated with verification and validation (V&V) are often application-specific. Furthermore, models and measurement strategies do not exist which allow prediction of overall TRS performance in a given task based on knowledge of the performance characteristics of individual subsystems. This paper introduces the use of general systems performance theory (GSPT), developed by the senior author to help resolve similar problems in human performance, as a basis for: (1) measurement of overall TRS performance (viewing all system components, including the operator, as a single entity); (2) task decomposition; (3) development of a generic TRS model; and (4) the characterization of performance of subsystems comprising the generic model. GSPT uses a resource construct to model performance and resource economic principles to govern the interface of systems to tasks. It provides a comprehensive modeling/measurement strategy applicable to complex systems including both human and artificial components. Application is presented in the context of a distributed telerobotics network (Universities Space Automation and Robotics Consortium) as a testbed. Insight into the design of test protocols which elicit application-independent data (i.e., multi-purpose or reusable) is described. Although the work is motivated by space automation and robotics challenges, it is considered to be applicable to telerobotic systems in general.

  12. Measurement science in the circulatory system.

    PubMed

    Jones, Casey M; Baker-Groberg, Sandra M; Cianchetti, Flor A; Glynn, Jeremy J; Healy, Laura D; Lam, Wai Yan; Nelson, Jonathan W; Parrish, Diana C; Phillips, Kevin G; Scott-Drechsel, Devon E; Tagge, Ian J; Zelaya, Jaime E; Hinds, Monica T; McCarty, Owen J T

    2014-03-01

    The dynamics of the cellular and molecular constituents of the circulatory system are regulated by the biophysical properties of the heart, vasculature and blood cells and proteins. In this review, we discuss measurement techniques that have been developed to characterize the physical and mechanical parameters of the circulatory system across length scales ranging from the tissue scale (centimeter) to the molecular scale (nanometer) and time scales of years to milliseconds. We compare the utility of measurement techniques as a function of spatial resolution and penetration depth from both a diagnostic and research perspective. Together, this review provides an overview of the utility of measurement science techniques to study the spatial systems of the circulatory system in health and disease.

  13. Measurement science in the circulatory system

    PubMed Central

    Jones, Casey M.; Baker-Groberg, Sandra M.; Cianchetti, Flor A.; Glynn, Jeremy J.; Healy, Laura D.; Lam, Wai Yan; Nelson, Jonathan W.; Parrish, Diana C.; Phillips, Kevin G.; Scott-Drechsel, Devon E.; Tagge, Ian J.; Zelaya, Jaime E.; Hinds, Monica T.; McCarty, Owen J.T.

    2014-01-01

    The dynamics of the cellular and molecular constituents of the circulatory system are regulated by the biophysical properties of the heart, vasculature and blood cells and proteins. In this review, we discuss measurement techniques that have been developed to characterize the physical and mechanical parameters of the circulatory system across length scales ranging from the tissue scale (centimeter) to the molecular scale (nanometer) and time scales of years to milliseconds. We compare the utility of measurement techniques as a function of spatial resolution and penetration depth from both a diagnostic and research perspective. Together, this review provides an overview of the utility of measurement science techniques to study the spatial systems of the circulatory system in health and disease. PMID:24563678

  14. Foot Plantar Pressure Measurement System: A Review

    PubMed Central

    Razak, Abdul Hadi Abdul; Zayegh, Aladin; Begg, Rezaul K.; Wahab, Yufridin

    2012-01-01

    Foot plantar pressure is the pressure field that acts between the foot and the support surface during everyday locomotor activities. Information derived from such pressure measures is important in gait and posture research for diagnosing lower limb problems, footwear design, sport biomechanics, injury prevention and other applications. This paper reviews foot plantar sensors characteristics as reported in the literature in addition to foot plantar pressure measurement systems applied to a variety of research problems. Strengths and limitations of current systems are discussed and a wireless foot plantar pressure system is proposed suitable for measuring high pressure distributions under the foot with high accuracy and reliability. The novel system is based on highly linear pressure sensors with no hysteresis. PMID:23012576

  15. Thermoelectric property measurements with computer controlled systems

    NASA Technical Reports Server (NTRS)

    Chmielewski, A. B.; Wood, C.

    1984-01-01

    A joint JPL-NASA program to develop an automated system to measure the thermoelectric properties of newly developed materials is described. Consideration is given to the difficulties created by signal drift in measurements of Hall voltage and the Large Delta T Seebeck coefficient. The benefits of a computerized system were examined with respect to error reduction and time savings for human operators. It is shown that the time required to measure Hall voltage can be reduced by a factor of 10 when a computer is used to fit a curve to the ratio of the measured signal and its standard deviation. The accuracy of measurements of the Large Delta T Seebeck coefficient and thermal diffusivity was also enhanced by the use of computers.

  16. A Critique of Health System Performance Measurement.

    PubMed

    Lynch, Thomas

    2015-01-01

    Health system performance measurement is a ubiquitous phenomenon. Many authors have identified multiple methodological and substantive problems with performance measurement practices. Despite the validity of these criticisms and their cross-national character, the practice of health system performance measurement persists. Theodore Marmor suggests that performance measurement invokes an "incantatory response" wrapped within "linguistic muddle." In this article, I expand upon Marmor's insights using Pierre Bourdieu's theoretical framework to suggest that, far from an aberration, the "linguistic muddle" identified by Marmor is an indicator of a broad struggle about the representation and classification of public health services as a public good. I present a case study of performance measurement from Alberta, Canada, examining how this representational struggle occurs and what the stakes are.

  17. Thermoelectric property measurements with computer controlled systems

    NASA Technical Reports Server (NTRS)

    Chmielewski, A. B.; Wood, C.

    1984-01-01

    A joint JPL-NASA program to develop an automated system to measure the thermoelectric properties of newly developed materials is described. Consideration is given to the difficulties created by signal drift in measurements of Hall voltage and the Large Delta T Seebeck coefficient. The benefits of a computerized system were examined with respect to error reduction and time savings for human operators. It is shown that the time required to measure Hall voltage can be reduced by a factor of 10 when a computer is used to fit a curve to the ratio of the measured signal and its standard deviation. The accuracy of measurements of the Large Delta T Seebeck coefficient and thermal diffusivity was also enhanced by the use of computers.

  18. Data on directionality measures of adaptive systems

    NASA Astrophysics Data System (ADS)

    Nilsson, Michael J.; Wellington, Jim; Kirsch, Jay; Bray, Victor

    2005-09-01

    Directionality has become the dominant method to improve the signal-to-noise ratio in hearing aids. Quantification of differences in the amount of directionality between systems has become a source of scientific, as well as marketing, interest. Developments in directionality now involve signal processing methods that interact with directional microphones based upon adaptive algorithms in order to broaden the appeal and usefulness of these systems. The ANSI S3.35 revision for 2004 improves the methodology for relating measures of directionality to expected performance when using many systems, but fails to address measurements using these adaptive systems. These systems respond differently depending upon the type, volume, or location of a stimulus, and will generate different results using the single noise source technique included in the standard compared to diffuse noise conditions. This presentation presents data using various measurement techniques to quantify the differences between directional systems. Different types of adaptive systems will be identified that vary in their interaction with the ANSI methods and an understanding of how measurements change with changes in technique will be presented.

  19. Passive Accelerometer System Measurements on MIR

    NASA Technical Reports Server (NTRS)

    Alexander, J. Iwan D.

    1997-01-01

    The Passive Accelerometer System (PAS) is a simple moving ball accelerometer capable of measuring the small magnitude steady relative acceleration that occurs in a low earth orbit spacecraft due to atmospheric drag and the earth's gravity gradient. The acceleration is measured by recording the average velocity of the spherical ball over a suitable time increment. A modified form of Stokes law is used to convert the average velocity into an acceleration. PAS was used to measure acceleration on the MIR space station and on the first United States Microgravity Laboratory (USML-1). The PAS measurement on MIR revealed remarkably low acceleration levels in the SPEKTR module.

  20. Noncontact dimensional measurement system using holographic scanning

    NASA Astrophysics Data System (ADS)

    Sagan, Stephen F.; Rosso, Robert S.; Rowe, David M.

    1997-07-01

    Holographic scanning systems have been used for years in point-of-sale bar code scanners and other low resolution applications. These simple scanning systems could not successfully provide the accuracy and precision required to measure, inspect and control the production of today's high tech optical fibers, medical extrusions and electrical cables. A new class of instruments for the precision measurement of industrial processes has been created by the development of systems with a unique combination of holographic optical elements that can compensate for the wavelength drift in laser diodes, the application of proprietary post-processing algorithms, and the advancements in replication methods to fabricate low cost holographic scanning discs. These systems have improved upon the performance of traditional polygon mirror scanners. This paper presents the optical configuration and design features that have been incorporated into a holographic scanning inspection system that provides higher productivity, increased product quality and lower production costs for many manufacturers.

  1. Noninvasive ambulatory measurement system of cardiac activity.

    PubMed

    Pino, Esteban J; Chavez, Javier A P; Aqueveque, Pablo

    2015-01-01

    This work implements a noninvasive system that measures the movements caused by cardiac activity. It uses unobtrusive Electro-Mechanical Films (EMFi) on the seat and on the backrest of a regular chair. The system detects ballistocardiogram (BCG) and respiration movements. Real data was obtained from 54 volunteers. 19 of them were measured in the laboratory and 35 in a hospital waiting room. Using a BIOPAC acquisition system, the ECG was measured simultaneously to the BCG for comparison. Wavelet Transform (WT) is a better option than Empirical Mode Decomposition (EMD) for signal extraction and produces higher effective measurement time. In the laboratory, the best results are obtained on the seat. The correlation index was 0.9800 and the Bland-Altman limits of agreement were 0.7136 ± 4.3673 [BPM]. In the hospital waiting room, the best results are also from the seat sensor. The correlation index was 0.9840, and the limits of agreement were 0.4386 ± 3.5884 [BPM]. The system is able to measure BCG in an unobtrusive way and determine the cardiac frequency with high precision. It is simple to use, which means the system can easily be used in non-standard settings: resting in a chair or couch, at the gym, schools or in a hospital waiting room, as shown.

  2. In-vitro corneal transparency measuring system

    NASA Astrophysics Data System (ADS)

    Ventura, Liliane; da Costa Vieira, Marcelo A.; Isaac, Flavio; Chiaradia, Caio; Faria de Sousa, Sidney J.

    2001-06-01

    A system for measuring the average corneal transparency of preserved corneas has been developed in order to provide a more accurate and standard report of the corneal tissue. The donated cornea transparency is one of the features to be analyzed previously to its indication for the transplant. The small portable system consists of two main parts: the optical and the electronic parts. The optical system consists of a white light, lenses and pin-holes that collimate white light beams that illuminates the cornea in its preservative medium. The light that passes through the cornea is detected by a resistive detector and the average corneal transparency is shown in a display. In order to obtain just the tissue transparency, the electronic circuit was built in a way that there is a baseline input of the preservative medium, previous to the measurement of the corneal transparency. Manipulating the system consists of three steps: (1) Adjusting the zero percentage in the absence of light (at this time the detectors in the dark); (2) Placing the preservative medium in the system and adjusting the 100% value (this is the baseline input); (3) Preserving the cornea and placing it in the system. The system provides the tissue transparency. The system is connected to an endothelium evaluation system for Slit Lamp, that we have developed, and statistics about the relationship of the corneal transparency and density of the endothelial cells will be provided in the next years. The system is being used in a public Eye Bank in Brasil.

  3. Magnetic Field Response Measurement Acquisition System

    NASA Technical Reports Server (NTRS)

    Woodard, Stanley E.; Taylor,Bryant D.; Shams, Qamar A.; Fox, Robert L.

    2007-01-01

    This paper presents a measurement acquisition method that alleviates many shortcomings of traditional measurement systems. The shortcomings are a finite number of measurement channels, weight penalty associated with measurements, electrical arcing, wire degradations due to wear or chemical decay and the logistics needed to add new sensors. Wire degradation has resulted in aircraft fatalities and critical space launches being delayed. The key to this method is the use of sensors designed as passive inductor-capacitor circuits that produce magnetic field responses. The response attributes correspond to states of physical properties for which the sensors measure. Power is wirelessly provided to the sensing element by using Faraday induction. A radio frequency antenna produces a time-varying magnetic field used to power the sensor and receive the magnetic field response of the sensor. An interrogation system for discerning changes in the sensor response frequency, resistance and amplitude has been developed and is presented herein. Multiple sensors can be interrogated using this method. The method eliminates the need for a data acquisition channel dedicated to each sensor. The method does not require the sensors to be near the acquisition hardware. Methods of developing magnetic field response sensors and the influence of key parameters on measurement acquisition are discussed. Examples of magnetic field response sensors and the respective measurement characterizations are presented. Implementation of this method on an aerospace system is discussed.

  4. Fluid-filled blood pressure measurement systems.

    PubMed

    Li, J K; van Brummelen, A G; Noordergraaf, A

    1976-05-01

    The performance of catheter-manometer systems for the measurement of pulsatile pressure has been evaluated by both experimental techniques and theoretical considerations. The former approach has shown, on occasion, multiple maxima in the amplitude response. The latter has been approached in a variety of ways, ranging from extreme lumping to application of transmission line theory while employing different configurations in the system's representation. Multiple maxima have also been seen, The present paper identifies the sources of the differences found and compares the relative merits of various theoretical approaches. It introduces the compliance of the system as a figure of merit and provides a simple first-order approximation formula for evaluation of the quality of a system. Damping and impedance matching to improve the system's frequency response were studied. It was found that they were not needed in a very stiff or a very compliant system, nor should one worry about the representation of such a system.

  5. A unique, accurate LWIR optics measurement system

    NASA Astrophysics Data System (ADS)

    Fantone, Stephen D.; Orband, Daniel G.

    2011-05-01

    A compact low-cost LWIR test station has been developed that provides real time MTF testing of IR optical systems and EO imaging systems. The test station is intended to be operated by a technician and can be used to measure the focal length, blur spot size, distortion, and other metrics of system performance. The challenges and tradeoffs incorporated into this instrumentation will be presented. The test station performs the measurement of an IR lens or optical system's first order quantities (focal length, back focal length) including on and off-axis imaging performance (e.g., MTF, resolution, spot size) under actual test conditions to enable the simulation of their actual use. Also described is the method of attaining the needed accuracies so that derived calculations like focal length (EFL = image shift/tan(theta)) can be performed to the requisite accuracy. The station incorporates a patented video capture technology and measures MTF and blur characteristics using newly available lowcost LWIR cameras. This allows real time determination of the optical system performance enabling faster measurements, higher throughput and lower cost results than scanning systems. Multiple spectral filters are also accommodated within the test stations which facilitate performance evaluation under various spectral conditions.

  6. Laser Doppler Velocimeter particle velocity measurement system

    SciTech Connect

    Wilson, W.W.; Srikantaiah, D.V.; Philip, T.; George, A.

    1993-10-01

    This report gives a detailed description of the operation of the Laser Doppler Velocimeter (LDV) system maintained by DIAL at MSU. LDV is used for the measurement of flow velocities and turbulence levels in various fluid flow settings. Ills report details the operation and maintenance of the LDV system and provides a first-time user with pertinent information regarding the system`s setup for a particular application. Particular attention has been given to the use of the Doppler signal analyzer (DSA) and the burst spectrum analyzer (BSA) signal processors and data analysis.

  7. Development of limb volume measuring system

    NASA Technical Reports Server (NTRS)

    Bhagat, P. K.; Kadaba, P. K.

    1983-01-01

    The mechanisms underlying the reductions in orthostatic tolerance associated with weightlessness are not well established. Contradictory results from measurements of leg volume changes suggest that altered venomotor tone and reduced blood flow may not be the only contributors to orthostatic intolerance. It is felt that a more accurate limb volume system which is insensitive to environmental factors will aid in better quantification of the hemodynamics of the leg. Of the varous limb volume techniques presently available, the ultrasonic limb volume system has proven to be the best choice. The system as described herein is free from environmental effects, safe, simple to operate and causes negligible radio frequency interference problems. The segmental ultrasonic ultrasonic plethysmograph is expected to provide a better measurement of limb volume change since it is based on cross-sectional area measurements.

  8. Video integrated measurement system. [Diagnostic display devices

    SciTech Connect

    Spector, B.; Eilbert, L.; Finando, S.; Fukuda, F.

    1982-06-01

    A Video Integrated Measurement (VIM) System is described which incorporates the use of various noninvasive diagnostic procedures (moire contourography, electromyography, posturometry, infrared thermography, etc.), used individually or in combination, for the evaluation of neuromusculoskeletal and other disorders and their management with biofeedback and other therapeutic procedures. The system provides for measuring individual diagnostic and therapeutic modes, or multiple modes by split screen superimposition, of real time (actual) images of the patient and idealized (ideal-normal) models on a video monitor, along with analog and digital data, graphics, color, and other transduced symbolic information. It is concluded that this system provides an innovative and efficient method by which the therapist and patient can interact in biofeedback training/learning processes and holds considerable promise for more effective measurement and treatment of a wide variety of physical and behavioral disorders.

  9. Laser measuring system for large machine tools

    NASA Astrophysics Data System (ADS)

    Wessel, L. E.; Brazys, D.

    1982-08-01

    With development of the Laser Interferometer, it was envisioned that older existing machine tools could be up-graded by retrofitting them with laser Interferometer Measuring Systems. The Laser Interferometer provides the machine tool industry with a high accuracy length standard. The accuracy of the Interferometer is determined by the laser wave length which is known within 0.5 parts per million. This degree of accuracy is more than adequate for most machine tool measuring, calibration and inspection requirements. In conclusion, the Laser Measuring System presently available is not recommended for general implementation at this time. Results of this work indicate that the equipment and installation cost are very high and pay back would be very slow. Also, the reliability of the electronic components is in need of improvement. The system requires frequent realignment and maintenance due to it's lack of toleration to "Shop Floor' conditions.

  10. Radiated microwave power transmission system efficiency measurements

    NASA Technical Reports Server (NTRS)

    Dickinson, R. M.; Brown, W. C.

    1975-01-01

    The measured and calculated results from determining the operating efficiencies of a laboratory version of a system for transporting electric power from one point to another via a wireless free space radiated microwave beam are reported. The system's overall end-to-end efficiency as well as intermediated conversion efficiencies were measured. The maximum achieved end-to-end dc-to-ac system efficiency was 54.18% with a probable error of + or - 0.94%. The dc-to-RF conversion efficiency was measured to be 68.87% + or - 1.0% and the RF-to-dc conversion efficiency was 78.67 + or - 1.1%. Under these conditions a dc power of 495.62 + or - 3.57 W was received with a free space transmitter antenna receiver antenna separation of 170.2 cm (67 in).

  11. Birefringence measurement in complex optical systems

    NASA Astrophysics Data System (ADS)

    Knell, Holger; Heuck, Hans-Martin

    2017-06-01

    State of the art optical systems become more complex. There are more lenses required in the optical design and optical coatings have more layers. These complex designs are prone to induce more thermal stress into the optical system which causes birefringence. In addition, there is a certain degree of freedom required to meet optical specifications during the assembly process. The mechanical fixation of these degrees of freedom can also lead to mechanical stress in the optical system and therefore to birefringence. To be able to distinguish those two types of stress a method to image the birefringence in the optical system is required. In the proposed setup light is polarized by a circular polarization filter and then is transmitted through a rotatable linear retarder and the tested optical system. The light then is reflected on the same path by a mirror. After the light passes the circular polarization filter on the way back, the intensity is recorded. When the rotatable retarder is rotated, the recorded intensity is modulated depending on the birefringence of the tested optical system. This modulation can be analyzed in Fourier domain and the linear retardance angle between the slow and the fast axis as well as the angle of the fast axis can be calculated. The retardance distribution over the pupil of the optical system then can be analyzed using Zernike decomposition. From the Zernike decomposition, the origin of the birefringence can be identified. Since it is required to quantify small amounts of retardance well below 10nm, the birefringence of the measurement system must be characterized before the measurement and considered in the calculation of the resulting birefringence. Temperature change of the measurement system still can produce measurement artifacts in the calculated result, which must also be compensated for.

  12. Differential Measurement Periodontal Structures Mapping System

    NASA Technical Reports Server (NTRS)

    Companion, John A. (Inventor)

    1998-01-01

    This invention relates to a periodontal structure mapping system employing a dental handpiece containing first and second acoustic sensors for locating the Cemento-Enamel Junction (CEJ) and measuring the differential depth between the CEJ and the bottom of the periodontal pocket. Measurements are taken at multiple locations on each tooth of a patient, observed, analyzed by an optical analysis subsystem, and archived by a data storage system for subsequent study and comparison with previous and subsequent measurements. Ultrasonic transducers for the first and second acoustic sensors are contained within the handpiece and in connection with a control computer. Pressurized water is provided for the depth measurement sensor and a linearly movable probe sensor serves as the sensor for the CEJ finder. The linear movement of the CEJ sensor is obtained by a control computer actuated by the prober. In an alternate embodiment, the CEJ probe is an optical fiber sensor with appropriate analysis structure provided therefor.

  13. Optical strain measurement system development, phase 1

    NASA Technical Reports Server (NTRS)

    Lant, Christian T.; Qaqish, Walid

    1987-01-01

    A laser speckle, differential strain measurement system was built and tested for future applications in hostile environments. One dimensional electronic correlation of speckle pattern movement allows a quasi-real time measure of strain. The system was used successfully to measure uniaxial strain reaching into plastic deformation of a test specimen, at temperatures ranging to 450 C. A resolution of 16 microstrain is given by the photodiode array sensor pitch and the specimen to sensor separation. The strain measurement limit of the gauge is determined by air density perturbations causing decorrelation of the reference and shifted speckle patterns, and may be improved by limiting convective flow in the immediate vicinity of the test specimen.

  14. The Holdup Measurement System II (HMSII)

    SciTech Connect

    Smith, S.E.; Gibson, J.S.; Halbig, J.K.; Klosterbuer, S.F.; Russo, P.A.; Sprinkle, J.K. Jr.

    1993-07-12

    A project is in progress that addresses two of the problems with existing holdup measurement technology: the need for compact instrumentation and a more efficient means of reducing the massive amounts of data to quantities of Special Nuclear Materials (SNM). The approach taken by the project utilizes the Miniature Modular MultiChannel Analyzer (M{sup 3}CA), a complete and truly portable gamma-ray spectroscopy system, under development at Los Alamos National Laboratory. The hardware is then integrated and automated by the Holdup Measurement System II (HMSII) software being developed by the Oak Ridge Y-12 Plant. Together they provide the hardware components, measurement control in the field, automated data acquisition, data storage and manipulation which simplify holdup measurements.

  15. Eddy Correlation Flux Measurement System Handbook

    SciTech Connect

    Cook, D. R.

    2016-01-01

    The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO2) (and methane at one Southern Great Plains extended facility (SGP EF) and the North Slope of Alaska Central Facility (NSA CF). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO2 concentration. The instruments used are: • a fast-response, three-dimensional (3D) wind sensor (sonic anemometer) to obtain the orthogonal wind components and the speed of sound (SOS) (used to derive the air temperature) • an open-path infrared gas analyzer (IRGA) to obtain the water vapor density and the CO2 concentration, and • an open-path infrared gas analyzer (IRGA) to obtain methane density and methane flux at one SGP EF and at the NSA CF. The ECOR systems are deployed at the locations where other methods for surface flux measurements (e.g., energy balance Bowen ratio [EBBR] systems) are difficult to employ, primarily at the north edge of a field of crops. A Surface Energy Balance System (SEBS) has been installed collocated with each deployed ECOR system in SGP, NSA, Tropical Western Pacific (TWP), ARM Mobile Facility 1 (AMF1), and ARM Mobile Facility 2 (AMF2). The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. The SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes. The SEBS at one SGP and one NSA site also support upwelling and downwelling PAR measurements to qualify those two locations as Ameriflux sites.

  16. Measures of Autonomic Nervous System Regulation

    DTIC Science & Technology

    2011-04-01

    flowing out of the lungs. The optimal level of the individual’s lung function is measured by using three color-coded peak flow zones. The individual...amphetamines, alcohol and monoamine oxidase inhibitors, which may interfere with accurate measurements of catecholamine metabolites. Three tools for...wireless PDA-Based physiological monitoring system for patient transport . IEEE Trans Inf Technol Biomed. 2004;8(4):439. 25. Blank JM, Altman DG

  17. Measurement theory for closed quantum systems

    NASA Astrophysics Data System (ADS)

    Wouters, Michiel

    2015-07-01

    We introduce the concept of a “classical observable” as an operator with vanishingly small quantum fluctuations on a set of density matrices. Their study provides a natural starting point to analyse the quantum measurement problem. In particular, it allows to identify Schrödinger cats and the associated projection operators intrinsically, without the need to invoke an environment. We discuss how our new approach relates to the open system analysis of quantum measurements and to thermalization studies in closed quantum systems.

  18. Phase Measurement System for Gravitational Wave Detection

    NASA Astrophysics Data System (ADS)

    Klipstein, William

    We propose to advance the maturity of the LISA Phasemeter based on our recent experience developing a flight Phasemeter for the Laser Ranging Interferometer (LRI) on NASA's GRACE Follow-On mission. Our three main objectives are to: 1) incorporate the flight GRACE Follow-on LRI phasemeter developments into the TRL4 LISA design used extensively in our interferometer testbed; 2) evaluate the LRI Phasemeter against LISA's more stringent requirements in order to identify required design changes; 3) advance the design maturity of the LISA phasemeter through an architecture study to maintain the viability of the Phasemeter as a contribution to ESA's L3 gravitational wave mission. NASA intends to partner in the European Space Agency's (ESA) Gravitational-Wave detection mission, selected for the L3 mission to launch in 2034. This is expected to be a LISA-like mission with the two enabling LISA technologies: 1. a drag-free system to mitigate or measure non-gravitational forces on the spacecraft, 2. an interferometric measure¬ment system with precision phasemeters to measure picometer variations over the million kilometer separation between the spacecraft. To validate the key technologies of the drag-free system, the ESA LISA Pathfinder (LPF) mission is currently demonstrating a gravitational reference sensor (GRS) and microNewton thrusters in space. While LPF has an on-board interferometer to measure proof- mass motion with respect to the spacecraft, the LPF interferometer does not test the interspacecraft laser interferometry needed for a LISA-like mission. To validate the key technologies of the LISA interferometric measurement, the JPL LISA Phase Measurement Team has studied and developed a prototype LISA phase measurement system. This phase measurement system has also been adapted for a demonstration mission, albeit in a different arena. GRACE Follow-Ons Laser Ranging Interferometer (LRI), due to launch in late 2017, will make LISA-like inter-spacecraft interferometric

  19. Arterial compliance measurement using a noninvasive laser Doppler measurement system

    NASA Astrophysics Data System (ADS)

    Hast, Jukka T.; Myllylae, Risto A.; Sorvoja, Hannu; Nissilae, Seppo M.

    2000-11-01

    The aim of this study was to study the elasticity of the arterial wall using a non-invasive laser Doppler measurement system. The elasticity of the arterial wall is described by its compliance factor, which can be determined when both blood pressure and the radial velocity of the arterial wall are known. To measure radical velocity we used a self- mixing interferometer. The compliance factors were measured from six healthy volunteers, whose ages were varied from 21 to 32. Although a single volunteer's compliance factor is presented as an example, this paper treated the volunteers as a group. First, the elastic modulus, which is inversely proportional to the compliance factor, was determined. Then, an exponential curve was fitted into the measured data and a characteristic equation for the elastic modulus of the arterial wall was determined. The elastic modulus was calculated at different pressures and the results were compared to the static incremental modulus of a dog's femoral artery. The results indicate that there is a correlation between human elastic and canine static incremental modulus for blood pressures varying from 60 to 110 mmHg.

  20. High temperature hall effect measurement system design, measurement and analysis

    NASA Astrophysics Data System (ADS)

    Berkun, Isil

    A reliable knowledge of the transport properties of semiconductor materials is essential for the development and understanding of a number of electronic devices. In this thesis, the work on developing a Hall Effect measurement system with software based data acqui- sition and control for a temperature range of 300K-700K will be described. A system was developed for high temperature measurements of materials including single crystal diamond, poly-crystalline diamond, and thermoelectric compounds. An added capability for monitor- ing the current versus voltage behavior of the contacts was used for studying the influence of ohmic and non-ohmic contacts on Hall Effect measurements. The system has been primar- ily used for testing the transport properties of boron-doped single crystal diamond (SCD) deposited in a microwave plasma-assisted chemical vapor deposition (MPCVD) reactor [1]. Diamond has several outstanding properties that are of high interest for its development as an electronic material. These include a relatively wide band gap of 5.5 (eV), high thermal conductivity, high mobility, high saturation velocity, and a high breakdown voltage. For a temperature range of 300K-700K, IV curves, Hall mobilities and carrier concentrations are shown. Temperature dependent Hall effect measurements have shown carrier concentrations from below 1017cm --3 to approximately 1021 cm--3 with mobilities ranging from 763( cm2/V s) to 0.15(cm 2/V s) respectively. Simulation results have shown the effects of single and mixed carrier models, activation energies, effective mass and doping concentrations. These studies have been helpful in the development of single crystal diamond for diode applications. Reference materials of Ge and GaAs were used to test the Hall Effect system. The system was also used to characterize polycrystalline diamond deposited on glass for electrochemical applications, and Mg2(Si,Sn) compounds which are promising candidates of low-cost, light weight and non

  1. Videogrammetric Model Deformation Measurement System User's Manual

    NASA Technical Reports Server (NTRS)

    Dismond, Harriett R.

    2002-01-01

    The purpose of this manual is to provide the user of the NASA VMD system, running the MDef software, Version 1.10, all information required to operate the system. The NASA Videogrammetric Model Deformation system consists of an automated videogrammetric technique used to measure the change in wing twist and bending under aerodynamic load in a wind tunnel. The basic instrumentation consists of a single CCD video camera and a frame grabber interfaced to a computer. The technique is based upon a single view photogrammetric determination of two-dimensional coordinates of wing targets with fixed (and known) third dimensional coordinate, namely the span-wise location. The major consideration in the development of the measurement system was that productivity must not be appreciably reduced.

  2. Optoelectronic System for Measuring Warhead Fragments Velocity

    NASA Astrophysics Data System (ADS)

    Liu, Ji; Zhao, Donge; Li, Yangjun; Zhou, Hanchang

    2011-02-01

    High-speed warhead fragments velocity measurement is one of the key technologies in investigating damage efficiency of warhead. We have designed and constructed a system to accurately determine the velocity of warhead fragments by measuring the time of flight between two parallel laser screens is presented. Each screen is formed by a laser source, a large photodetector and a retro-reflector. Optical output of the laser source is a collimated beam. The beam passes through cylindrical lens and the slit of photodetector reach to retro-reflector .The energy, reflected by retro-reflector; focus on the active area of photodetector. The system utilizes reflected ray by scotchlite retro-reflector as the start and end signal. And utilizes wideband circuit and data acquiring system to condition and sample signals. Experimental results show the system can measurement velocity are within the range from 20m/s to 2000m/s on target area of 1m2 and can perform satisfactorily with a wide range from 2000 lx to100,000lx. The measurement system also can be used to test velocity of projectile.

  3. An interferometric strain-displacement measurement system

    NASA Technical Reports Server (NTRS)

    Sharpe, William N., Jr.

    1989-01-01

    A system for measuring the relative in-plane displacement over a gage length as short as 100 micrometers is described. Two closely spaced indentations are placed in a reflective specimen surface with a Vickers microhardness tester. Interference fringes are generated when they are illuminated with a He-Ne laser. As the distance between the indentations expands or contracts with applied load, the fringes move. This motion is monitored with a minicomputer-controlled system using linear diode arrays as sensors. Characteristics of the system are: (1) gage length ranging from 50 to 500 micrometers, but 100 micrometers is typical; (2) least-count resolution of approximately 0.0025 micrometer; and (3) sampling rate of 13 points per second. In addition, the measurement technique is non-contacting and non-reinforcing. It is useful for strain measurements over small gage lengths and for crack opening displacement measurements near crack tips. This report is a detailed description of a new system recently installed in the Mechanisms of Materials Branch at the NASA Langley Research Center. The intent is to enable a prospective user to evaluate the applicability of the system to a particular problem and assemble one if needed.

  4. Advanced Microgravity Acceleration Measurement Systems Being Developed

    NASA Technical Reports Server (NTRS)

    Sicker, Ronald J.; Kacpura, Thomas J.

    2002-01-01

    The Advanced Microgravity Acceleration Measurement Systems (AMAMS) project at the NASA Glenn Research Center is part of the Instrument Technology Development program to develop advanced sensor systems. The primary focus of the AMAMS project is to develop microelectromechanical (MEMS) acceleration sensor systems to replace existing electromechanical-sensor-based systems presently used to assess relative gravity levels aboard spacecraft. These systems are used in characterizing both vehicle and payload responses to low-gravity vibroacoustic environments. The collection of microgravity acceleration data has cross-disciplinary utility to the microgravity life and physical sciences and the structural dynamics communities. The inherent advantages of semiconductor-based systems are reduced size, mass, and power consumption, while providing enhanced stability.

  5. Combat-Ready Crew Performance Measurement System.

    DTIC Science & Technology

    1974-12-01

    station, as shown in Figure 11, must permit the transformacion of data collected through the five avenues shown in Figure 9 into a digital format...Measureti\\ent System: The performance measurement system consists of the following subsystems: (1) Data Acquisition. A hybrid audio/video/photo/ digital ...processing is provided. (2) Data Processing. A general purpose digital computer with standard peripherals is required, hi addition to executive and

  6. Observational Requirements and Measurement Systems Concepts

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Six philosophical elements that a measurement strategy for dynamic qualities should contain are: systemic global observations; nested coverage; continuous upgrading of observational capability and testing of promising instrument concepts; orbit considerations; quality control: data validity and management; and data interpretation. The criteria for determining an observational program should include the following: significance of the primary scientific questions, technical readiness; potential of undeveloped techniques, engineering and economic feasibility; and data access and data systems.

  7. Tutorial: Clock and Clock Systems Performance Measures

    DTIC Science & Technology

    1995-12-01

    TUTORIAL: CLOCK AND CLOCK SYSTEMS PERFORMANCE MEASURES David W. Allan Allan’s TIME Introduction This tutorial contains basic material...very important ITU Handbook being prepared at this tim; which goes much further than this tutorial has time to do. I highly recommend it as an...the world who have written the ten chapters in this handbook. The title of the Handbook is, "Selection and use of Precise Frequency and Time Systems

  8. Measurement techniques of LC display systems

    NASA Astrophysics Data System (ADS)

    Kosmowski, Bogdan B.; Becker, Michael E.; Neumeier, Juergen

    1993-10-01

    The strong increase of applications of liquid crystal displays in various areas (measuring, medical equipment, automotive, telecommunication, office, etc.) has forced the demand for the adequate specification of the LCDs performances. The optical, electro-optical and spectral properties of LCDs are strongly dependent on viewing direction, electrical driving conditions, illumination and temperature. All these quantities have to be precisely controlled, when one of them is varied, the resulting optical response of the object is recorded. In this paper we present measuring methods proposed for LCD panels and the computer controlled measuring system (DMS) for their evaluation.

  9. CARS system for turbulent flame measurements

    NASA Technical Reports Server (NTRS)

    Antcliff, R. R.; Jarrett, O., Jr.; Rogers, R. C.

    1984-01-01

    Simultaneous nitrogen number density and rotational-vibrational temperatures were measured in a turbulent diffusion flame with a Coherent Anti-Stokes Raman Scattering (CARS) instrument. The fuel jet was diluted with nitrogen (20 percent by volume) to allow temperature measurements across the entire jet mixing region. These measurements were compared with fluid dynamics computations. The CARS system incorporated a neodymium YAG laser, an intensified silicon photodiode array detector, and unique dynamic range enhancement methods. Theoretical calculations were based on a parabolic Navier-Stokes computer code. The comparison of these techniques will aid their development in the study of complex flowfields.

  10. Improved perceptual-motor performance measurement system

    NASA Technical Reports Server (NTRS)

    Parker, J. F., Jr.; Reilly, R. E.

    1969-01-01

    Battery of tests determines the primary dimensions of perceptual-motor performance. Eighteen basic measures range from simple tests to sophisticated electronic devices. Improved system has one unit for the subject containing test display and response elements, and one for the experimenter where test setups, programming, and scoring are accomplished.

  11. Vapor Pressure Measurements in a Closed System

    ERIC Educational Resources Information Center

    Iannone, Mark

    2006-01-01

    An alternative method that uses a simple apparatus to measure vapor pressure versus temperature in a closed system, in which the total pressure is the vapor pressure of the liquid sample, is described. The use of this apparatus gives students a more direct picture of vapor pressure than the isoteniscope method and results have generally been quite…

  12. Vapor Pressure Measurements in a Closed System

    ERIC Educational Resources Information Center

    Iannone, Mark

    2006-01-01

    An alternative method that uses a simple apparatus to measure vapor pressure versus temperature in a closed system, in which the total pressure is the vapor pressure of the liquid sample, is described. The use of this apparatus gives students a more direct picture of vapor pressure than the isoteniscope method and results have generally been quite…

  13. Multidirectional four-dimensional shape measurement system

    NASA Astrophysics Data System (ADS)

    Lenar, Janusz; Sitnik, Robert; Witkowski, Marcin

    2012-03-01

    Currently, a lot of different scanning techniques are used for 3D imaging of human body. Most of existing systems are based on static registration of internal structures using MRI or CT techniques as well as 3D scanning of outer surface of human body by laser triangulation or structured light methods. On the other hand there is an existing mature 4D method based on tracking in time the position of retro-reflective markers attached to human body. There are two main drawbacks of this solution: markers are attached to skin (no real skeleton movement is registered) and it gives (x, y, z, t) coordinates only in those points (not for the whole surface). In this paper we present a novel multidirectional structured light measurement system that is capable of measuring 3D shape of human body surface with frequency reaching 60Hz. The developed system consists of two spectrally separated and hardware-synchronized 4D measurement heads. The principle of the measurement is based on single frame analysis. Projected frame is composed from sine-modulated intensity pattern and a special stripe allowing absolute phase measurement. Several different geometrical set-ups will be proposed depending on type of movements that are to be registered.

  14. Sustainable Food Security Measurement: A Systemic Methodology

    NASA Astrophysics Data System (ADS)

    Findiastuti, W.; Singgih, M. L.; Anityasari, M.

    2017-04-01

    Sustainable food security measures how a region provides food for its people without endangered the environment. In Indonesia, it was legally measured in Food Security and Vulnerability (FSVA). However, regard to sustainable food security policy, the measurement has not encompassed the environmental aspect. This will lead to lack of environmental aspect information for adjusting the next strategy. This study aimed to assess Sustainable Food security by encompassing both food security and environment aspect using systemic eco-efficiency. Given existing indicator of cereal production level, total emission as environment indicator was generated by constructing Causal Loop Diagram (CLD). Then, a stock-flow diagram was used to develop systemic simulation model. This model was demonstrated for Indonesian five provinces. The result showed there was difference between food security order with and without environmental aspect assessment.

  15. Improving competitiveness through performance-measurement systems.

    PubMed

    Stewart, L J; Lockamy, A

    2001-12-01

    Parallels exist between the competitive pressures felt by U.S. manufacturers over the past 30 years and those experienced by healthcare providers today. Increasing market deregulation, changing government policies, and growing consumerism have altered the healthcare arena. Responding to similar pressures, manufacturers adopted a strategic orientation driven by customer needs and expectations that led them to achieve high performance levels and surpass their competition. The adoption of integrated performance-measurement systems was instrumental in these firms' success. An integrated performance-measurement model for healthcare organizations can help to blend the organization's strategy with the demands of the contemporary healthcare environment. Performance-measurement systems encourage healthcare organizations to focus on their mission and vision by aligning their strategic objectives and resource-allocation decisions with customer requirements.

  16. Acoustic systems for the measurement of streamflow

    USGS Publications Warehouse

    Laenen, Antonius; Smith, Winchell

    1982-01-01

    Very little information is available concerning acoustic velocity meter (AVM) operation, performance, and limitations. This report provides a better understanding about the application of AVM instrumentation to streamflow measurment. Operational U.S. Geological Survey systems have proven that AVM equipment is accurate and dependable. AVM equipment has no practical upper limit of measureable velocity if sonic transducers are securely placed and adequately protected, and will measure velocitites as low as 0.1 meter per second which is normally less than the threshold level for mechanical or head-loss meters. In some situations the performance of AVM equipment may be degraded by multipath interference, signal bending, signal attenuation, and variable streamline orientation. Smaller, less-expensive, more conveniently operable microprocessor equipment is now available which should increase use of AVM systems in streamflow applications. (USGS)

  17. Blade Vibration Measurement System for Unducted Fans

    NASA Technical Reports Server (NTRS)

    Marscher, William

    2014-01-01

    With propulsion research programs focused on new levels of efficiency and noise reduction, two avenues for advanced gas turbine technology are emerging: the geared turbofan and ultrahigh bypass ratio fan engines. Both of these candidates are being pursued as collaborative research projects between NASA and the engine manufacturers. The high bypass concept from GE Aviation is an unducted fan that features a bypass ratio of over 30 along with the accompanying benefits in fuel efficiency. This project improved the test and measurement capabilities of the unducted fan blade dynamic response. In the course of this project, Mechanical Solutions, Inc. (MSI) collaborated with GE Aviation to (1) define the requirements for fan blade measurements; (2) leverage MSI's radar-based system for compressor and turbine blade monitoring; and (3) develop, validate, and deliver a noncontacting blade vibration measurement system for unducted fans.

  18. Low cost automated precise time measurement system

    NASA Technical Reports Server (NTRS)

    Alpert, A.; Liposchak, P.

    1973-01-01

    The Aerospace Guidance and Metrology Center (AGMC) has the responsibility for the dissemination of Precise Time and Time Interval (PTTI) to Air Force timing systems requiring microsecond time. In order to maintain traceability to the USNO Master Clock in Washington D.C., and accomplish efficient logging of time and frequency data on individual precision clocks, a simple automatic means of acquiring precise time has been devised. The Automatic Time Interval Measurement System (ATIMS) consists of a minicomputer (8K Memory), teletype terminal, electronic counter, Loran C receiver, time base generator and locally-manufactured relay matrix panel. During the measurement process, the computer controls the relay matrix which selects for comparison 13 atomic clocks against a reference clock and the reference versus Loran C. Through use of the system teletype, the operator is able to set the system clock (hours, minutes and seconds), examine and/or modify all clock data and constants, and set measurement intervals. This is done in a conversational manner. A logic flow diagram, system schematic, source listing and software components are included in the presentation.

  19. Multi-scale biomedical systems: measurement challenges

    NASA Astrophysics Data System (ADS)

    Summers, R.

    2016-11-01

    Multi-scale biomedical systems are those that represent interactions in materials, sensors, and systems from a holistic perspective. It is possible to view such multi-scale activity using measurement of spatial scale or time scale, though in this paper only the former is considered. The biomedical application paradigm comprises interactions that range from quantum biological phenomena at scales of 10-12 for one individual to epidemiological studies of disease spread in populations that in a pandemic lead to measurement at a scale of 10+7. It is clear that there are measurement challenges at either end of this spatial scale, but those challenges that relate to the use of new technologies that deal with big data and health service delivery at the point of care are also considered. The measurement challenges lead to the use, in many cases, of model-based measurement and the adoption of virtual engineering. It is these measurement challenges that will be uncovered in this paper.

  20. System for measuring radioactivity of labelled biopolymers

    SciTech Connect

    Gross, V.

    1980-07-08

    A system is described for measuring radioactivity of labelled biopolymers, comprising: a set of containers adapted for receiving aqueous solutions of biological samples containing biopolymers which are subsequently precipitated in said containers on particles of diatomite in the presence of a coprecipitator, then filtered, dissolved, and mixed with a scintillator; radioactivity measuring means including a detection chamber to which is fed the mixture produced in said set of containers; an electric drive for moving said set of containers in a stepwise manner; means for proportional feeding of said coprecipitator and a suspension of diatomite in an acid solution to said containers which contain the biological sample for forming an acid precipitation of biopolymers; means for the removal of precipitated samples from said containers; precipitated biopolymer filtering means for successively filtering the precipitate, suspending the precipitate, dissolving the biopolymers mixed with said scintillator for feeding of the mixture to said detection chamber; a system of pipelines interconnecting said above-recited means; and said means for measuring radioactivity of labelled biopolymers including, a measuring cell arranged in a detection chamber and communicating with said means for filtering precipitated biopolymers through one pipeline of said system of pipelines; a program unit electrically connected to said electric drive, said means for acid precipatation of biopolymers, said means for the removal of precipitated samples from said containers, said filtering means, and said radioactivity measuring device; said program unit adapted to periodically switch on and off the above-recited means and check the sequence of the radioactivity measuring operations; and a control unit for controlling the initiation of the system and for selecting programs.

  1. Linescan Camera System for 100% Moisture Measurement

    SciTech Connect

    Hernandez, J E; Koo, J; Romero, C; Vigars, M; Newman, M; Dallum, G

    2006-10-11

    Lawrence Livermore National Laboratory (LLNL), in collaboration with ABB Industrial Systems, and under the sponsorship of the Department of Energy's (DOE) Office of Industrial Technologies (OIT), has developed a new method for measuring the moisture content of a paper web process on-line with 100% coverage of the sheet. The method uses InGaAs linear arrays with associated optics and electronics to continuously image the full width of the web and measure transmitted light at 1.45{micro} and another suitable reference wavelength between 1{micro} and 1.6{micro}. The method could also be used to measure paper basis weight, in addition to moisture, by adding additional hardware and optics to measure a third wavelength at 1.57{micro}. A patent (USP: 6355931), entitled ''System and method for 100% moisture and basis weight measurement of moving paper'', was granted by the US Patent Office on March 12, 2002 for this invention. A proof-of-concept prototype system was also developed and tested on several occasions at ABB's sensors development facility in Columbus, Ohio. Based on current experimental results, the system seems particularly suitable for detecting moisture variation on a paper web for medium and heavy weight products at the dry end as well as the press section of the machine. The prototype system was scheduled to be tested at a paper mill in the fall of 2001. The test had to be canceled as ABB was unable to provide the required field support for the test due to restructuring and down-sizing of their R&D organization.

  2. Torsional ultrasonic wave based level measurement system

    DOEpatents

    Holcomb, David E [Oak Ridge, TN; Kisner, Roger A [Knoxville, TN

    2012-07-10

    A level measurement system suitable for use in a high temperature and pressure environment to measure the level of coolant fluid within the environment, the system including a volume of coolant fluid located in a coolant region of the high temperature and pressure environment and having a level therein; an ultrasonic waveguide blade that is positioned within the desired coolant region of the high temperature and pressure environment; a magnetostrictive electrical assembly located within the high temperature and pressure environment and configured to operate in the environment and cooperate with the waveguide blade to launch and receive ultrasonic waves; and an external signal processing system located outside of the high temperature and pressure environment and configured for communicating with the electrical assembly located within the high temperature and pressure environment.

  3. Measurement systems for cell adhesive forces.

    PubMed

    Zhou, Dennis W; García, Andrés J

    2015-02-01

    Cell adhesion to the extracellular matrix (ECM) involves integrin receptor-ligand binding and clustering to form focal adhesion (FA) complexes, which mechanically link the cell's cytoskeleton to the ECM and regulate fundamental cell signaling pathways. Although elucidation of the biochemical events in cell-matrix adhesive interactions is rapidly advancing, recent studies show that the forces underlying cell-matrix adhesive interactions are also critical to cell responses. Therefore, multiple measurement systems have been developed to quantify the spatial and temporal dynamics of cell adhesive forces, and these systems have identified how mechanical events influence cell phenotype and FA structure-function relationships under physiological and pathological settings. This review focuses on the development, methodology, and applications of measurement systems for probing (a) cell adhesion strength and (b) 2D and 3D cell traction forces.

  4. Measuring Entanglement in Condensed Matter Systems

    SciTech Connect

    Cramer, M.; Wunderlich, H.; Plenio, M. B.

    2011-01-14

    We show how entanglement may be quantified in spin and cold atom many-body systems using standard experimental techniques only. The scheme requires no assumptions on the state in the laboratory, and a lower bound to the entanglement can be read off directly from the scattering cross section of neutrons deflected from solid state samples or the time-of-flight distribution of cold atoms in optical lattices, respectively. This removes a major obstacle which so far has prevented the direct and quantitative experimental study of genuine quantum correlations in many-body systems: The need for a full characterization of the state to quantify the entanglement contained in it. Instead, the scheme presented here relies solely on global measurements that are routinely performed and is versatile enough to accommodate systems and measurements different from the ones we exemplify in this work.

  5. Error measuring system of rotary Inductosyn

    NASA Astrophysics Data System (ADS)

    Liu, Chengjun; Zou, Jibin; Fu, Xinghe

    2008-10-01

    The inductosyn is a kind of high-precision angle-position sensor. It has important applications in servo table, precision machine tool and other products. The precision of inductosyn is calibrated by its error. It's an important problem about the error measurement in the process of production and application of the inductosyn. At present, it mainly depends on the method of artificial measurement to obtain the error of inductosyn. Therefore, the disadvantages can't be ignored such as the high labour intensity of the operator, the occurrent error which is easy occurred and the poor repeatability, and so on. In order to solve these problems, a new automatic measurement method is put forward in this paper which based on a high precision optical dividing head. Error signal can be obtained by processing the output signal of inductosyn and optical dividing head precisely. When inductosyn rotating continuously, its zero position error can be measured dynamically, and zero error curves can be output automatically. The measuring and calculating errors caused by man-made factor can be overcome by this method, and it makes measuring process more quickly, exactly and reliably. Experiment proves that the accuracy of error measuring system is 1.1 arc-second (peak - peak value).

  6. Gear Transmission Error Measurement System Made Operational

    NASA Technical Reports Server (NTRS)

    Oswald, Fred B.

    2002-01-01

    A system directly measuring the transmission error between the meshing spur or helical gears was installed at the NASA Glenn Research Center and made operational in August 2001. This system employs light beams directed by lenses and prisms through gratings mounted on the two gear shafts. The amount of light that passes through both gratings is directly proportional to the transmission error of the gears. The device is capable of resolution better than 0.1 mm (one thousandth the thickness of a human hair). The measured transmission error can be displayed in a "map" that shows how the transmission error varies with the gear rotation or it can be converted to spectra to show the components at the meshing frequencies. Accurate transmission error data will help researchers better understand the mechanisms that cause gear noise and vibration and will lead to The Design Unit at the University of Newcastle in England specifically designed the new system for NASA. It is the only device in the United States that can measure dynamic transmission error at high rotational speeds. The new system will be used to develop new techniques to reduce dynamic transmission error along with the resulting noise and vibration of aeronautical transmissions.

  7. Electro-optical spin measurement system

    NASA Technical Reports Server (NTRS)

    Fodale, Robert (Inventor); Hampton, Herbert R. (Inventor)

    1990-01-01

    An electro-optical spin measurement system for a spin model in a spin tunnel includes a radio controlled receiver/transmitter, targets located on the spin model, optical receivers mounted around the perimeter of the spin tunnel and the base of the spin tunnel for receiving data from the targets, and a control system for accumulating data from the radio controlled receiver and receivers. Six targets are employed. The spin model includes a fuselage, wings, nose, and tail. Two targets are located under the fuselage of the spin model at the nose tip and tail. Two targets are located on the side of the fuselage at the nose tip and tail, and a target is located under each wing tip. The targets under the fuselage at the nose tip and tail measure spin rate of the spin model, targets on the side of the fuselage at the nose tip and tail measure angle of attack of the spin model, and the targets under the wing tips measure roll angle of the spin model. Optical receivers are mounted at 90 degree increments around the periphery of the spin tunnel to determine angle of attack and roll angle measurements of the spin model. Optical receivers are also mounted at the base of the spin tunnel to define quadrant and position of the spin model and to determine the spin rate of the spin model.

  8. Acquisition systems for heat transfer measurement

    SciTech Connect

    De Witt, R.J.

    1983-01-01

    Practical heat transfer data acquisition systems are normally characterized by the need for high-resolution, low-drift, low-speed recording devices. Analog devices such as strip chart or circular recorders and FM analog magnetic tape have excellent resolution and work well when data will be presented in temperature versus time format only and need not be processed further. Digital systems are more complex and require an understanding of the following components: digitizing devices, interface bus types, processor requirements, and software design. This paper discusses all the above components of analog and digital data acquisition, as they are used in current practice. Additional information on thermocouple system analysis will aid the user in developing accurate heat transfer measuring systems.

  9. Eddy Correlation Flux Measurement System (ECOR) Handbook

    SciTech Connect

    Cook, DR

    2011-01-31

    The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO2) (and methane at one Southern Great Plains extended facility (SGP EF) and the North Slope of Alaska Central Facility (NSA CF). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO2 concentration.

  10. Recent aerodynamic measurements with Magnetic Suspension Systems

    NASA Technical Reports Server (NTRS)

    Britcher, Colin P.

    1989-01-01

    This paper reviews recent aerodynamic tests of a family of slanted-base ogive-cylinders using the NASA Langley 13-inch Magnetic Suspension and Balance System. Results include drag, lift, pitching moment, support interference and base pressure measurements. Mach numbers were in the range 0.04 to 0.2. Drag results are shown to be in satisfactory agreement with previous measurements. Significant support interferences were found at all test conditions. Comparison is made between interference free base pressures, obtained using remote telemetry, and sting cavity pressures. Test results and procedures are briefly discussed in the context of the proposed helium flow facility.

  11. Electric Field Quantitative Measurement System and Method

    NASA Technical Reports Server (NTRS)

    Generazio, Edward R. (Inventor)

    2016-01-01

    A method and system are provided for making a quantitative measurement of an electric field. A plurality of antennas separated from one another by known distances are arrayed in a region that extends in at least one dimension. A voltage difference between at least one selected pair of antennas is measured. Each voltage difference is divided by the known distance associated with the selected pair of antennas corresponding thereto to generate a resulting quantity. The plurality of resulting quantities defined over the region quantitatively describe an electric field therein.

  12. Velocity and turbulence measurements in combustion systems

    NASA Astrophysics Data System (ADS)

    Goldstein, R. J.; Lau, K. Y.; Leung, C. C.

    1983-06-01

    A laser-Doppler velocimeter is used in the measurement of high-temperature gas flows. A two-stage fluidization particle generator provides magnesium oxide particles to serve as optical scattering centers. The one-dimensional dual-beam system is frequency shifted to permit measurements of velocities up to 300 meters per second and turbulence intensities greater than 100 percent. Exiting flows from can-type gas turbine combustors and burners with pre-mixed oxy-acetylene flames are described in terms of the velocity, turbulence intensity, and temperature profiles. The results indicate the influence of the combustion process on turbulence.

  13. El Sistema's Open Secrets

    ERIC Educational Resources Information Center

    Booth, Eric

    2011-01-01

    In this article, the author talks about Venezuela's national youth orchestra program called El Sistema whose attributes offer a direct challenge to traditional Western music practices. As U.S. classical music--and all "high arts"--struggle to find relevance to more than the small "arts club" percentage of the U.S. populace, El…

  14. El Sistema's Open Secrets

    ERIC Educational Resources Information Center

    Booth, Eric

    2011-01-01

    In this article, the author talks about Venezuela's national youth orchestra program called El Sistema whose attributes offer a direct challenge to traditional Western music practices. As U.S. classical music--and all "high arts"--struggle to find relevance to more than the small "arts club" percentage of the U.S. populace, El…

  15. Kiernan reentry measurements system on Kwajalein atoll

    SciTech Connect

    Roth, K.R.; Austin, M.E.; Frediani, D.J.; Knittel, G.H.; Mrstik, A.V.

    1989-01-01

    The Kiernan Reentry Measurements System (KREMS), located on Kwajalein Atoll in the Pacific, is the United States' most sophisticated and important research and development radar site. Consisting of four one-of-a-kind instrumentation radars, KREMS has played a major role for the past 25 years in the collection of data associated with ICBM testing. Furthermore, it has served as an important space-surveillance facility that provides an early U.S. view of many Soviet and Chinese satellite launches. Finally, the system is slated to play a key role in Strategic Defense Initiative experiments.

  16. Thermodynamics of Weakly Measured Quantum Systems.

    PubMed

    Alonso, Jose Joaquin; Lutz, Eric; Romito, Alessandro

    2016-02-26

    We consider continuously monitored quantum systems and introduce definitions of work and heat along individual quantum trajectories that are valid for coherent superposition of energy eigenstates. We use these quantities to extend the first and second laws of stochastic thermodynamics to the quantum domain. We illustrate our results with the case of a weakly measured driven two-level system and show how to distinguish between quantum work and heat contributions. We finally employ quantum feedback control to suppress detector backaction and determine the work statistics.

  17. Thermodynamics of Weakly Measured Quantum Systems

    NASA Astrophysics Data System (ADS)

    Alonso, Jose Joaquin; Lutz, Eric; Romito, Alessandro

    2016-02-01

    We consider continuously monitored quantum systems and introduce definitions of work and heat along individual quantum trajectories that are valid for coherent superposition of energy eigenstates. We use these quantities to extend the first and second laws of stochastic thermodynamics to the quantum domain. We illustrate our results with the case of a weakly measured driven two-level system and show how to distinguish between quantum work and heat contributions. We finally employ quantum feedback control to suppress detector backaction and determine the work statistics.

  18. Measuring cell identity in noisy biological systems

    PubMed Central

    Birnbaum, Kenneth D.; Kussell, Edo

    2011-01-01

    Global gene expression measurements are increasingly obtained as a function of cell type, spatial position within a tissue and other biologically meaningful coordinates. Such data should enable quantitative analysis of the cell-type specificity of gene expression, but such analyses can often be confounded by the presence of noise. We introduce a specificity measure Spec that quantifies the information in a gene's complete expression profile regarding any given cell type, and an uncertainty measure dSpec, which measures the effect of noise on specificity. Using global gene expression data from the mouse brain, plant root and human white blood cells, we show that Spec identifies genes with variable expression levels that are nonetheless highly specific of particular cell types. When samples from different individuals are used, dSpec measures genes’ transcriptional plasticity in each cell type. Our approach is broadly applicable to mapped gene expression measurements in stem cell biology, developmental biology, cancer biology and biomarker identification. As an example of such applications, we show that Spec identifies a new class of biomarkers, which exhibit variable expression without compromising specificity. The approach provides a unifying theoretical framework for quantifying specificity in the presence of noise, which is widely applicable across diverse biological systems. PMID:21803789

  19. Measurements for low level RF control systems

    NASA Astrophysics Data System (ADS)

    Simrock, S. N.

    2007-08-01

    The low level RF control system for the European x-ray free electron laser, which is based on TESLA technology, requires information on a large number of signals and parameters which are either directly measurable as physical signals or must be derived from the physical signals. In most cases, calibrations are required to obtain the desired quantities. The measured signals are used in the real time feedback loops for field and resonance control, and for diagnostic purposes to support automation and exception handling. Good system models and powerful signal processors (including field programmable gate arrays and digital signal processors) combined with fast communication links allow for processing a large number of complex algorithms in real time. Several of these algorithms have been implemented at the free electron laser at Hamburg (FLASH) for evaluation and have increased the availability of the facility for user operation.

  20. POLRADS: polarization radiance distribution measurement system.

    PubMed

    Voss, Kenneth J; Souaidia, Nordine

    2010-09-13

    While the upwelling radiance distribution in the ocean can be highly polarized, there are few measurements of this parameter in the open ocean. To obtain the polarized in-water upwelling spectral radiance distribution data we have developed the POLRADS instrument. This instrument is based on the NuRADS radiance distribution camera systems in which linear polarizer's have been installed. By combining simultaneous images from three NuRADS instruments, three Stokes parameters (I, Q, U) for the water leaving radiance can be obtained for all upwelling angles simultaneously. This system measures the Stokes parameters Q/I and U/I with a 0.05-0.06 uncertainty and I with a 7-10% uncertainty.

  1. Rotating Rake Turbofan Duct Mode Measurement System

    NASA Technical Reports Server (NTRS)

    Sutliff, Daniel L.

    2005-01-01

    An experimental measurement system was developed and implemented by the NASA Glenn Research Center in the 1990s to measure turbofan duct acoustic modes. The system is a continuously rotating radial microphone rake that is inserted into the duct. This Rotating Rake provides a complete map of the acoustic duct modes present in a ducted fan and has been used on a variety of test articles: from a low-speed, concept test rig, to a full-scale production turbofan engine. The Rotating Rake has been critical in developing and evaluating a number of noise reduction concepts as well as providing experimental databases for verification of several aero-acoustic codes. More detailed derivation of the unique Rotating Rake equations are presented in the appendix.

  2. A portable magnetic induction measurement system (PIMS).

    PubMed

    Cordes, Axel; Foussier, Jérôme; Pollig, Daniel; Leonhardt, Steffen

    2012-02-22

    For contactless monitoring of ventilation and heart activity, magnetic induction measurements are applicable. As the technique is harmless for the human body, it is well suited for long-term monitoring solutions, e.g., bedside monitoring, monitoring of home care patients, and the monitoring of persons in critical occupations. For such settings, a two-channel portable magnetic induction system has been developed, which is small and light enough to be fitted in a chair or bed. Because demodulation, control, and filtering are implemented on a front-end digital signal processor, a PC is not required (except for visualization/data storage during research and development). The system can be connected to a local area network (LAN) or wireless network (WiFi), allowing to connect several devices to a large monitoring system, e.g., for a residential home for the elderly or a hospital with low-risk patients not requiring standard ECG monitoring. To visualize data streams, a Qt-based (Qt-framework by Nokia, Espoo, Finland) monitoring application has been developed, which runs on Netbook computers, laptops, or standard PCs. To induce and measure the magnetic fields, external coils and amplifiers are required. This article describes the system and presents results for monitoring respiration and heart activity in a (divan) bed and for respiration monitoring in a chair. Planar configurations and orthogonal coil setups were examined during the measurement procedures. The measurement data were streamed over a LAN to a monitoring PC running Matlab (The MathWorks Inc, Natick, MA, USA).

  3. Triangulation Measurements in the Solar System

    DTIC Science & Technology

    2000-03-01

    ephemeris and establishing an alternative scale of stellar distances. The accuracy of the angular measurements is expected to attain the...adaptation in the world. It is just that principle that is laid in origin of all scale systems in modern astronomy as well. The maximum usage of the...is quite necessary for practical computation of the initial conditions of passive motion, as well as for the guidance and the full- scale metrology

  4. Fiberoptic probe and system for spectral measurements

    DOEpatents

    Dai, Sheng; Young, Jack P.

    1998-01-01

    A fused fiberoptic probe, a system, method and embodiments thereof for conducting spectral measurements are disclosed. The fused fiberoptic probe comprises a probe tip having a specific geometrical configuration, an exciting optical fiber and at least one collection optical fiber fused within a housing, preferrably silica. The specific geometrical configurations in which the probe tip can be shaped include a slanted probe tip with an angle greater than 0.degree., an inverted cone-shaped probe tip, and a lens head.

  5. Hot Wall Thickness Variation Measurement System

    DTIC Science & Technology

    1979-06-01

    Subtltia) HOT WALL THICKNESS VARIATION MEASUREMENT SYSTEM 7. AUTHORfa; 3. J. KRUPSKI 9 . PERFORMING ORGANIZATION NAME AND ADDRESS PRODUCT...THE FORGING 3. ULTRASONICS ON A HOT TUBE 4. SYSTEt-l DESCRIPTION 5. TESTING RESULTS 6. CONCLUSIONS 7. HffLEMENTATION PAGE i ii 1 2 4 6 9 ...printed out. The grip procedure was repeated toward the breech end of the forging with good results. The third and 9 breech end prints were at about

  6. Plume Measurement System (PLUMES) Calibration Experiment

    DTIC Science & Technology

    1994-08-01

    Atle Lohrmann SonTek, Inc. 7940 Silverton Avenue, No. 105 San Diego, California 92126 and Craig Huhta JIMAR University of Hawaii, Honolulu, Hawaii 96822...Measurement System (PLUMES) Calibration Experiment by Age Lohrmann SonTek, Inc. 7940 Silverton Avenue, No. 105 San Diego, CA 92126 Craig Huhta JIMAR...PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) &. PERFORMING ORGANIZATION SonTek, Inc., 7940 Silverton Avenue, No. 105, San Diego, CA 92126 REPORT NUMBER

  7. Fiberoptic probe and system for spectral measurements

    DOEpatents

    Dai, S.; Young, J.P.

    1998-10-13

    A fused fiberoptic probe, a system, method and embodiments thereof for conducting spectral measurements are disclosed. The fused fiberoptic probe comprises a probe tip having a specific geometrical configuration, an exciting optical fiber and at least one collection optical fiber fused within a housing, preferably silica. The specific geometrical configurations in which the probe tip can be shaped include a slanted probe tip with an angle greater than 0{degree}, an inverted cone-shaped probe tip, and a lens head. 12 figs.

  8. Space Acceleration Measurement System-II

    NASA Technical Reports Server (NTRS)

    Foster, William

    2009-01-01

    Space Acceleration Measurement System (SAMS-II) is an ongoing study of the small forces (vibrations and accelerations) on the ISS that result from the operation of hardware, crew activities, as well as dockings and maneuvering. Results will be used to generalize the types of vibrations affecting vibration-sensitive experiments. Investigators seek to better understand the vibration environment on the space station to enable future research.

  9. Small expendable deployer system measurement analysis

    NASA Technical Reports Server (NTRS)

    Carrington, Connie K.

    1988-01-01

    The first on-orbit experiment of the Small Expendable Deployer System (SEDS) for tethered satellites will collect telemetry data for tether length, rate of deployment, and tether tension. The post-flight analysis will use this data to reconstruct the deployment history and determine dynamic characteristics such as tether shape and payload position. Linearized observability analysis has determined that these measurements are adequate to define states for a two-mass tether model, and two state estimators were written.

  10. Directional emittance surface measurement system and process

    NASA Technical Reports Server (NTRS)

    Puram, Chith K. (Inventor); Daryabeigi, Kamran (Inventor); Wright, Robert (Inventor); Alderfer, David W. (Inventor)

    1994-01-01

    Apparatus and process for measuring the variation of directional emittance of surfaces at various temperatures using a radiometric infrared imaging system. A surface test sample is coated onto a copper target plate provided with selective heating within the desired incremental temperature range to be tested and positioned onto a precision rotator to present selected inclination angles of the sample relative to the fixed positioned and optically aligned infrared imager. A thermal insulator holder maintains the target plate on the precision rotator. A screen display of the temperature obtained by the infrared imager, and inclination readings are provided with computer calculations of directional emittance being performed automatically according to equations provided to convert selected incremental target temperatures and inclination angles to relative target directional emittance values. The directional emittance of flat black lacquer and an epoxy resin measurements obtained are in agreement with the predictions of the electromagnetic theory and with directional emittance data inferred from directional reflectance measurements made on a spectrophotometer.

  11. Two-stage gas measurement system

    NASA Technical Reports Server (NTRS)

    Sprinkle, Danny R. (Inventor); Chen, Tony T. D. (Inventor); Chaturvedi, Sushil K. (Inventor)

    1994-01-01

    A quick-response, real-time gaseous measurement system allows for the continuous sampling of a low pressure gaseous environment. A sample of test gas from the low pressure gaseous environment is continuously extracted and pumped to a structural tee joint which is open to the atmosphere at one end to maintain the test gas at a constant pressure. The structural tee joint communicates at the other end with a heater for maintaining the test gas at a constant temperature. From the heater, the test gas is sent to a sensor which develops a voltage that is proportional to the partial pressure of the gaseous component to be measured in the test gas, a constant flow rate of test gas being provided through the heater and sensor. Since test gas pressure, temperature, and flow rate are being held constant, changes in sensor voltage are attributable only to changes in the concentration of the measured gas component.

  12. Aerodynamic Flow Field Measurements for Automotive Systems

    NASA Technical Reports Server (NTRS)

    Hepner, Timothy E.

    1999-01-01

    The design of a modern automotive air handling system is a complex task. The system is required to bring the interior of the vehicle to a comfortable level in as short a time as possible. A goal of the automotive industry is to predict the interior climate of an automobile using advanced computational fluid dynamic (CFD) methods. The development of these advanced prediction tools will enable better selection of engine and accessory components. The goal of this investigation was to predict methods used by the automotive industry. To accomplish this task three separate experiments were performed. The first was a laboratory setup where laser velocimeter (LV) flow field measurements were made in the heating and air conditioning unit of a Ford Windstar. The second involved flow field measurements in the engine compartment of a Ford Explorer, with the engine running idle. The third mapped the flow field exiting the center dashboard panel vent inside the Explorer, while the circulating fan operated at 14 volts. All three experiments utilized full-coincidence three-component LV systems. This enabled the mean and fluctuating velocities to be measured along with the Reynolds stress terms.

  13. Tritium monitoring system for near ambient measurements

    SciTech Connect

    Falter, K.G.; Bauer, M.L.

    1991-01-01

    This paper describes the current status of research on an improved tritium measurement system at the Oak Ridge National Laboratory (ORNL) for the US Navy. Present tritium-in-air monitoring systems installed by the Navy can reliably measure to less than 10 {mu}Ci/m{sup 3}, but medical and safety issues are pushing measurement needs to below 1 {mu}Ci/m{sup 3}, which is equivalent to 1--10 nCi/ml in liquid samples, using calcium metal converter. A significant effort has been expended over the past 10 years by the Navy RADIAC Development Program at ORNL on various schemes to improve the detection of tritium in both air and liquid at near ambient levels. One such scheme includes a liquid flow-through system based on an NE102 sponge scintillator with dual photomultiplier tubes for the tube noise rejection. (This document also contains copies of the slides used for presentation of this paper to the IEEE 1991 Nuclear Science Symposium). 4 refs., 17 figs.

  14. Hybrid system for magnetic and acoustic measurement.

    PubMed

    Bruno, A C; Baffa, O; Carneiro, A O

    2009-01-01

    In order to improve the spatial resolution of Biosusceptometry of Alternate Current (BAC), we are suggesting the coupling of a Doppler ultrasonic transducer with the BAC system. The Doppler transducer obtains information from the vibration of ferromagnetic particles immersed in a visco-elastic medium when it is excited by an alternating magnetic field. In this case, the same magnetic particles used as contrast for susceptometric measurement also will work as contrast for the Doppler measurement. In this work, we present the characterization of the hybrid system for susceptometric and acoustic measurements simultaneously. It was observed that the susceptometric and Doppler ultrasound signal have the same profile and maximum amplitude for frequency of magnetizing field about 200 Hz. When using ferrite particles as magnetic contrast mixed with yogurt as based material, the susceptometric and Doppler measurement have sensitivity for concentration of particles as low as 1%. The sensitivity of the Doppler is dependent of the gradient of magnetic field over the sample. In this work, the magnetic field 5 cm far from the face of the transducer was 70 microT/volts.

  15. NANONIS TRAMEA - A Quantum Transport Measurement System

    NASA Astrophysics Data System (ADS)

    Kampen, Thorsten; Thissen, Andreas; Schaff, Oliver; Pioda, Alessandro

    Nanonis Tramea is a quantum leap with respect to increased speed for transport measurements taking research onto a new level. Measurements which took several hours in the past can now be done in minutes without compromising signal quality. Tramea uses its fast, high-resolution, high-precision and ultra-low-noise outputs and inputs to generate and acquire up to 20000 data points per second on 24 channels in parallel. This is not only up to 1000 x faster than typical measurement systems but it is also time deterministic with highest precision. Here, the time separation between points is constant so that artefacts caused by unequal point spacings in non-deterministic measurement systems are avoided. The emphasis here is the real-time relation. Tramea comes with a built-in interface which allows for control of the instruments' basic functions from any programming environment. For users requiring more functionality and higher speeds a full-featured LabVIEW-based programming interface or scripting module are available as add-on modules. Due to the modularity and flexibility of the hardware and software architecture of Tramea upgrades with standardized add-on modules are possible. Non-standard requests can still be handled by the various programming options.

  16. Balanced interferometric system for stability measurements

    SciTech Connect

    Ellis, Jonathan D.; Joo, Ki-Nam; Spronck, Jo W.; Munnig Schmidt, Robert H

    2009-03-20

    We describe two different, double-sided interferometer designs for measuring material stability. Both designs are balanced interferometers where the only optical path difference is the sample and the reference beams are located within the interferometer. One interferometer is a double-pass design, whereas the other is a single-pass system. Based on a tolerancing analysis, the single-pass system is less susceptible to initial component misalignment and motions during experiments. This single-pass interferometer was tested with an 86 nm thin-film silver sample for both short-term repeatability and long-term stability. In 66 repeatability tests of 30 min each, the mean measured drift rate was less than 1 pm/h rms. In two long-term tests (>9 h), the mean drift rate was less than 1.1 pm/h, which shows good agreement between the short- and long-term measurements. In these experiments, the mean measured length change was 2 nm rms.

  17. Space Acceleration Measurement System for Free Flyers

    NASA Technical Reports Server (NTRS)

    Kacpura, Thomas J.

    1999-01-01

    Experimenters from the fluids, combustion, materials, and life science disciplines all use the microgravity environment of space to enhance their understanding of fundamental physical phenomena caused by disturbances from events such as spacecraft maneuvers, equipment operations, atmospheric drag, and (for manned flights) crew movement. Space conditions reduce gravity but do not eliminate it. To quantify the level of these disturbances, NASA developed the Space Acceleration Measurement System (SAMS) series to collect data characterizing the acceleration environment on the space shuttles. This information is provided to investigators so that they can evaluate how the microgravity environment affects their experiments. Knowledge of the microgravity environment also helps investigators to plan future experiments. The original SAMS system flew 20 missions on the shuttle as well as on the Russian space station Mir. Presently, Lewis is developing SAMS-II for the International Space Station; it will be a distributed system using digital output sensor heads. The latest operational version of SAMS, SAMS-FF, was originally designed for free flyer spacecraft and unmanned areas. SAMS-FF is a flexible, modular system, housed in a lightweight package, and it uses advances in technology to improve performance. The hardware package consists of a control and data acquisition module, three different types of sensors, data storage devices, and ground support equipment interfaces. Three different types of sensors are incorporated to measure both high- and low-frequency accelerations and the roll rate velocity. Small, low-power triaxial sensor heads (TSH's) offer high resolution and selectable bandwidth, and a special low-frequency accelerometer is available for high-resolution, low-frequency applications. A state-of-the-art, triaxial fiberoptic gyroscope that measures extremely low roll rates is housed in a compact package. The versatility of the SAMS-FF system is shown in the three

  18. Human eye color difference threshold measurement system

    NASA Astrophysics Data System (ADS)

    Liu, Lin; Zhou, Taogeng

    2013-12-01

    The human eye has the ability to distinguish millions of colors, with this feature we can identify very subtle color differences, and the measurement of human eye color difference threshold can provide a visual function diagnosis for testee. In recent years, people begin to focus on studies on visual threshold diagnostic equipment. This paper proposes a human eye color difference threshold measurement system which is based on dual integrating sphere. The system includes two pairs of dual integrating sphere and color control module. Dual integrating sphere uses to mix and produce color, and palette unit which produces primary colors (red (R), green (G), blue (B)) is embedded in dual integrating sphere. At the same time, the embedded palette unit which produces cyan (C), magenta (M), and yellow (Y) expands color area that the system can generate. One optical path based on dual integrating sphere generates standard color, the other path produces the matching color which is similar to a standard color. In the high-precision closed-loop color control module, photoelectric switch records stepper motor's origin position and limits move displacement. Precision stepper motor pushes the light-blocking panel of the palette unit to a predetermined position, while real-time monitoring the position of the light-blocking panel and mixing the ideal controllable color. Two colors that the system generates are projected onto the same target area. Subjects make a judgment on color difference threshold by observing the target eventually.

  19. A novel transient electromagnetic measuring system

    NASA Astrophysics Data System (ADS)

    Fu, Zhihong; Sun, Rui; Luo, Qiang; Chen, Qingli; Ma, Jing

    2006-11-01

    Transient electromagnetic measuring system, a kind of geophysics detecting devices, still have some technological problems unsolved in high current steep pulse transmitting, high precision synchronous control, large dynamic range signal gathering, etc., This paper proposes a novel transient electromagnetic measuring system(WTEM) with some technological improvements, including: (1) applying PocketPC and Bluetooth wireless technology in receivers to improve the system performance and reduces the receivers scale; (2) constructing a steep pulse transmitting circuit to output high current pulse with high linearity falling edge, short shut-off time and fast rising edge, finally improving the surficial resolving power; (3) proposing a GPS synchronous controller with high synchronous precision, in which TCXO working with GPS corporately, recovering the short-time invalidation of GPS module. In the project of detecting the oil pipeline corrosion, indoor and field tests have been done to WTEM system. The results indicate that WTEM possesses fine performances, short withdrawing time from saturation status, high synchronous precision and short turn-off time of transmitting current, etc..

  20. Sistemas Eolicos Pequenos para Generacion de Electridad (Spanish version of Small Wind Electric Systems: A U.S. Consumer's Guide)

    SciTech Connect

    Not Available

    2005-07-01

    This Spanish version of the popular Small Wind Electric Systems: A U.S. Consumer's Guide provides consumers with information to help them determine whether a small wind electric system can provide all or a portion of the energy they need for their home or business based on their wind resource, energy needs, and economics. Topics include how to make a home more energy efficient, how to choose the correct turbine size, the parts of a wind electric system, how to determine whether enough wind resource exists, how to choose the best site for a turbine, how to connect a system to the utility grid, and whether it's possible to become independent of the utility grid using wind energy. In addition, the cover of the guide contains a list of contacts for more information.

  1. Development of computerized masticatory force measurement system.

    PubMed

    Rane, Vivek; Hamde, Satish; Agrawal, Ankush

    2017-01-01

    The aim of this study was to assess the Maximum Voluntary Bite Force (MVBF) in Indian population with normal occlusion and after treatment of mandibular angle fracture. This paper discusses the development of a sensor fork with modified load cell and computer-based bite force measuring system that generates force profile on the computer. This is a powerful diagnostic tool in response to the needs of dentists seeking an accurate way to dynamically measure occlusion. This study was carried out to evaluate the maximum voluntary bite force generated by the patients after the treatment of mandibular angle fracture. The in vivo measurements were repeated on the following day, week and two months later. The measurements of the device were highly repeatable. This development provides the cost effective and handy equipment for bite force measurement further, if again sensor thickness reduced, we will be able to get more close results of forces that are exactly generated during the mastication process. Our study shows a significant difference in mean bite force efficiency between the all the treatment weeks and increased with time at α = 0.05 level. The gender difference was statistically significant in the male and female.

  2. New Gear Transmission Error Measurement System Designed

    NASA Technical Reports Server (NTRS)

    Oswald, Fred B.

    2001-01-01

    The prime source of vibration and noise in a gear system is the transmission error between the meshing gears. Transmission error is caused by manufacturing inaccuracy, mounting errors, and elastic deflections under load. Gear designers often attempt to compensate for transmission error by modifying gear teeth. This is done traditionally by a rough "rule of thumb" or more recently under the guidance of an analytical code. In order for a designer to have confidence in a code, the code must be validated through experiment. NASA Glenn Research Center contracted with the Design Unit of the University of Newcastle in England for a system to measure the transmission error of spur and helical test gears in the NASA Gear Noise Rig. The new system measures transmission error optically by means of light beams directed by lenses and prisms through gratings mounted on the gear shafts. The amount of light that passes through both gratings is directly proportional to the transmission error of the gears. A photodetector circuit converts the light to an analog electrical signal. To increase accuracy and reduce "noise" due to transverse vibration, there are parallel light paths at the top and bottom of the gears. The two signals are subtracted via differential amplifiers in the electronics package. The output of the system is 40 mV/mm, giving a resolution in the time domain of better than 0.1 mm, and discrimination in the frequency domain of better than 0.01 mm. The new system will be used to validate gear analytical codes and to investigate mechanisms that produce vibration and noise in parallel axis gears.

  3. Cuerpo de Paz Manual de Sistema de Programacion y Capacitacion (Peace Corps Programming and Training System Manual): T0063.

    ERIC Educational Resources Information Center

    Peace Corps, Washington, DC.

    This Spanish version of the Peace Corps Programming and Training System Manual is designed to help field staff members of the Peace Corps train volunteers. Its task descriptions, guidelines, examples, and definitions are intended to be practical and informative rather than restrictive. The manual is divided into six major sections: (1)…

  4. 3D optical measuring technologies and systems

    NASA Astrophysics Data System (ADS)

    Chugui, Yuri V.

    2005-02-01

    The results of the R & D activity of TDI SIE SB RAS in the field of the 3D optical measuring technologies and systems for noncontact 3D optical dimensional inspection applied to atomic and railway industry safety problems are presented. This activity includes investigations of diffraction phenomena on some 3D objects, using the original constructive calculation method. The efficient algorithms for precise determining the transverse and longitudinal sizes of 3D objects of constant thickness by diffraction method, peculiarities on formation of the shadow and images of the typical elements of the extended objects were suggested. Ensuring the safety of nuclear reactors and running trains as well as their high exploitation reliability requires a 100% noncontact precise inspection of geometrical parameters of their components. To solve this problem we have developed methods and produced the technical vision measuring systems LMM, CONTROL, PROFIL, and technologies for noncontact 3D dimensional inspection of grid spacers and fuel elements for the nuclear reactor VVER-1000 and VVER-440, as well as automatic laser diagnostic COMPLEX for noncontact inspection of geometric parameters of running freight car wheel pairs. The performances of these systems and the results of industrial testing are presented and discussed. The created devices are in pilot operation at Atomic and Railway Companies.

  5. SNAPSHOT: A MODERN, SUSTAINABLE HOLDUP MEASUREMENT SYSTEM

    SciTech Connect

    Rowe, Nathan C; Younkin, James R; Smith, Steven E; Chapman, Jeffrey Allen; Dunn, Michael E; Stewart, Scott L

    2016-01-01

    SNAPSHOT is a software platform designed to eventually replace Holdup Measurement System 4 (HMS 4), which is the current state-of-the-art for acquisition and analysis of nondestructive assay measurement data for in situ nuclear materials, holdup, in support of criticality safety and material control and accounting. HMS 4 is over 10 years old and is currently unsustainable due to hardware and software incompatibilities that have arisen from advances in detector electronics, primarily updates to multi-channel analyzers (MCAs), and both computer and handheld operating systems. SNAPSHOT is a complete redesign of HMS 4 that addresses the issue of compatibility with modern MCAs and operating systems and that is designed with a flexible architecture to support long-term sustainability. It also provides an updated and more user friendly interface and is being developed under an NQA 1 software quality assurance (SQA) program to facilitate site acceptance for safety-related applications. This paper provides an overview of the SNAPSHOT project including details of the software development process, the SQA program, and the architecture designed to support sustainability.

  6. Measurements of system sharpness for two digital breast tomosynthesis systems

    NASA Astrophysics Data System (ADS)

    Marshall, N. W.; Bosmans, H.

    2012-11-01

    The aim of this work was to propose system sharpness parameters for digital breast tomosynthesis (DBT) systems that include the influence of focus size and focus motion for use in quality assurance protocols. X-ray focus size was measured using a multiple pinhole test object, while detector presampling modulation transfer function (MTF) was measured from projection images of a 10 cm × 10 cm, 1 mm thick steel edge, for the Siemens Inspiration and Hologic Selenia Dimensions DBT systems. The height of the edge above the table was then varied from 1 to 78 mm. The MTF expected from theory for the projection images was calculated from the measured detector MTF, focus size MTF and focus motion MTF and was compared against measured curves. Two methods were used to measure the in-plane MTF in the DBT volume: a tungsten wire of diameter 25 µm and an Al edge 0.2 mm thick, both imaged with a 15 mm thick poly(methyl methacrylate) (PMMA) plate. The in-depth point spread function (PSF) was measured using an angled tungsten wire. The full 3D MTF was estimated with a 0.5 mm diameter aluminium bead held in a 45 mm thick PMMA phantom, with the bead 15 and 65 mm above the table. Inspiration DBT projection images are saved at native detector resolution (85 µm), while the Dimensions re-bins projections to 140 µm pixels (2 × 2 binning); both systems used 2 × 2 binning of projection data before reconstruction. The 50% point for the MTF (MTF0.50) measured in the DBT projection images for the tube-travel direction fell as a function of height above the table from 3.60 to 0.90 mm-1 for the Inspiration system and from 2.50 to 1.20 mm-1 for the Dimensions unit. The maximum deviation of measured MTF0.50 from the calculated value was 13%. MTF0.50 measured in-plane (tube-travel direction) fell as a function of height above the table from 1.66 to 0.97 mm-1 for the Inspiration system and from 2.21 to 1.31 mm-1 for the Dimensions system. The full-width half-maximum for the in-depth PSF was 3

  7. Measurements of system sharpness for two digital breast tomosynthesis systems.

    PubMed

    Marshall, N W; Bosmans, H

    2012-11-21

    The aim of this work was to propose system sharpness parameters for digital breast tomosynthesis (DBT) systems that include the influence of focus size and focus motion for use in quality assurance protocols. X-ray focus size was measured using a multiple pinhole test object, while detector presampling modulation transfer function (MTF) was measured from projection images of a 10 cm × 10 cm, 1 mm thick steel edge, for the Siemens Inspiration and Hologic Selenia Dimensions DBT systems. The height of the edge above the table was then varied from 1 to 78 mm. The MTF expected from theory for the projection images was calculated from the measured detector MTF, focus size MTF and focus motion MTF and was compared against measured curves. Two methods were used to measure the in-plane MTF in the DBT volume: a tungsten wire of diameter 25 µm and an Al edge 0.2 mm thick, both imaged with a 15 mm thick poly(methyl methacrylate) (PMMA) plate. The in-depth point spread function (PSF) was measured using an angled tungsten wire. The full 3D MTF was estimated with a 0.5 mm diameter aluminium bead held in a 45 mm thick PMMA phantom, with the bead 15 and 65 mm above the table. Inspiration DBT projection images are saved at native detector resolution (85 µm), while the Dimensions re-bins projections to 140 µm pixels (2 × 2 binning); both systems used 2 × 2 binning of projection data before reconstruction. The 50% point for the MTF (MTF(0.50)) measured in the DBT projection images for the tube-travel direction fell as a function of height above the table from 3.60 to 0.90 mm(-1) for the Inspiration system and from 2.50 to 1.20 mm(-1) for the Dimensions unit. The maximum deviation of measured MTF(0.50) from the calculated value was 13%. MTF(0.50) measured in-plane (tube-travel direction) fell as a function of height above the table from 1.66 to 0.97 mm(-1) for the Inspiration system and from 2.21 to 1.31 mm(-1) for the Dimensions system. The full-width half-maximum for the in

  8. Automatic actinometric system for diffuse radiation measurement

    NASA Astrophysics Data System (ADS)

    Litwiniuk, Agnieszka; Zajkowski, Maciej

    2015-09-01

    Actinometric station is using for measuring solar of radiation. The results are helpful in determining the optimal position of solar panels relative to the Sun, especially in today's world, when the energy coming from the Sun and other alternative sources of energy become more and more popular. Polish climate does not provide as much energy as in countries in southern Europe, but it is possible to increase the amount of energy produced by appropriate arrangement of photovoltaic panels. There is the possibility of forecasting the amount of produced energy, the cost-effectiveness and profitability of photovoltaic installations. This implies considerable development opportunities for domestic photovoltaic power plants. This article presents description of actinometric system for diffuse radiation measurement, which is equipped with pyranometer - thermopile temperature sensor, amplifier AD620, AD Converter ADS1110, microcontroller Atmega 16, SD card, GPS module and LCD screen.

  9. System and method for measuring residual stress

    DOEpatents

    Prime, Michael B.

    2002-01-01

    The present invention is a method and system for determining the residual stress within an elastic object. In the method, an elastic object is cut along a path having a known configuration. The cut creates a portion of the object having a new free surface. The free surface then deforms to a contour which is different from the path. Next, the contour is measured to determine how much deformation has occurred across the new free surface. Points defining the contour are collected in an empirical data set. The portion of the object is then modeled in a computer simulator. The points in the empirical data set are entered into the computer simulator. The computer simulator then calculates the residual stress along the path which caused the points within the object to move to the positions measured in the empirical data set. The calculated residual stress is then presented in a useful format to an analyst.

  10. Magnetic Field Response Measurement Acquisition System

    NASA Technical Reports Server (NTRS)

    Woodard, Stanley E. (Inventor); Taylor, Bryant D. (Inventor); Shams, Qamar A. (Inventor); Fox, Robert L. (Inventor); Fox, Christopher L. (Inventor); Fox, Melanie L. (Inventor); Bryant, Robert G. (Inventor)

    2006-01-01

    Magnetic field response sensors designed as passive inductor-capacitor circuits produce magnetic field responses whose harmonic frequencies correspond to states of physical properties for which the sensors measure. Power to the sensing element is acquired using Faraday induction. A radio frequency antenna produces the time varying magnetic field used for powering the sensor, as well as receiving the magnetic field response of the sensor. An interrogation architecture for discerning changes in sensor s response kequency, resistance and amplitude is integral to the method thus enabling a variety of measurements. Multiple sensors can be interrogated using this method, thus eliminating the need to have a data acquisition channel dedicated to each sensor. The method does not require the sensors to be in proximity to any form of acquisition hardware. A vast array of sensors can be used as interchangeable parts in an overall sensing system.

  11. Magnetic Field Response Measurement Acquisition System

    NASA Technical Reports Server (NTRS)

    Woodward, Stanley E. (Inventor); Taylor, Bryant D. (Inventor)

    2007-01-01

    Magnetic field response sensors designed as passive inductor- capacit or circuits produce magnetic field responses whose harmonic frequenci es correspond to states of physical properties for which the sensors measure. Power to the sensing element is acquired using Faraday induc tion. A radio frequency antenna produces the time varying magnetic fi eld used for powering the sensor, as well as receiving the magnetic field response of the sensor. An interrogation architecture for disce rning changes in sensor's response frequency, resistance and amplitud e is integral to the method thus enabling a variety of measurements. Multiple sensors can be interrogated using this method, thus eliminat ing the need to have a data acquisition channel dedicated to each se nsor. The method does not require the sensors to be in proximity to a ny form of acquisition hardware. A vast array of sensors can be used as interchangeable parts in an overall sensing system.

  12. Optical steam quality measurement system and method

    DOEpatents

    Davidson, James R.; Partin, Judy K.

    2006-04-25

    An optical measurement system is presented that offers precision on-line monitoring of the quality of steam. Multiple wavelengths of radiant energy are passed through the steam from an emitter to a detector. By comparing the amount of radiant energy absorbed by the flow of steam for each wavelength, a highly accurate measurement of the steam quality can be determined on a continuous basis in real-time. In an embodiment of the present invention, the emitter, comprises three separate radiant energy sources for transmitting specific wavelengths of radiant energy through the steam. In a further embodiment, the wavelengths of radiant energy are combined into a single beam of radiant energy for transmission through the steam using time or wavelength division multiplexing. In yet a further embodiment, the single beam of radiant energy is transmitted using specialized optical elements.

  13. Whole body measurement systems. [for weightlessness simulation

    NASA Technical Reports Server (NTRS)

    Ogle, J. S. (Inventor)

    1973-01-01

    A system for measuring the volume and volume variations of a human body under zero gravity conditions is disclosed. An enclosed chamber having a defined volume and arranged for receiving a human body is provided with means for infrasonically varying the volume of the chamber. The changes in volume produce resultant changes in pressure, and under substantially isentropic conditions, an isentropic relationship permits a determination of gas volume which, in turn, when related to total chamber volume permits a determination of the body volume. By comparison techniques, volume changes of a human independent of gravity conditions can be determined.

  14. Advanced high frequency partial discharge measuring system

    NASA Technical Reports Server (NTRS)

    Karady, George G.

    1994-01-01

    This report explains the Advanced Partial Discharge Measuring System in ASU's High Voltage Laboratory and presents some of the results obtained using the setup. While in operation an insulation is subjected to wide ranging temperature and voltage stresses. Hence, it is necessary to study the effect of temperature on the behavior of partial discharges in an insulation. The setup described in this report can be used to test samples at temperatures ranging from -50 C to 200 C. The aim of conducting the tests described herein is to be able to predict the behavior of an insulation under different operating conditions in addition to being able to predict the possibility of failure.

  15. Method of measurement in biological systems

    DOEpatents

    Turteltaub, K.W.; Vogel, J.S.; Felton, J.S.; Gledhill, B.L.: Davis, J.C.; Stanker, L.H.

    1993-05-11

    A method is disclosed of quantifying molecules in biological substances, comprising: selecting a biological host in which radioisotopes are present in concentrations equal to or less than those in the ambient biosphere; preparing a long-lived radioisotope labeled reactive chemical specie; administering the chemical specie to the biological host in doses sufficiently low to avoid significant overt damage to the biological system; allowing a period of time to elapse sufficient for dissemination and interaction of the chemical specie with the host throughout the biological system of the host; isolating a reacted fraction of the biological substance from the host in a manner sufficient to avoid contamination of the substance from extraneous sources; converting the fraction of biological substance by suitable means to a material which efficiently produces charged ions in at least one of several possible ion sources without introduction of significant isotopic fractionation; and measuring the radioisotope concentration in the material by means of direct isotopic counting.

  16. Material permeance measurement system and method

    DOEpatents

    Hallman, Jr., Russell Louis; Renner, Michael John [Oak Ridge, TN

    2012-05-08

    A system for measuring the permeance of a material. The permeability of the material may also be derived. The system provides a liquid or high concentration fluid bath on one side of a material test sample, and a gas flow across the opposing side of the material test sample. The mass flow rate of permeated fluid as a fraction of the combined mass flow rate of gas and permeated fluid is used to calculate the permeance of the material. The material test sample may be a sheet, a tube, or a solid shape. Operational test conditions may be varied, including concentration of the fluid, temperature of the fluid, strain profile of the material test sample, and differential pressure across the material test sample.

  17. Fluid permeability measurement system and method

    DOEpatents

    Hallman, Jr., Russell Louis; Renner, Michael John

    2008-02-05

    A system for measuring the permeance of a material. The permeability of the material may also be derived. The system provides a liquid or high concentration fluid bath on one side of a material test sample, and a gas flow across the opposing side of the material test sample. The mass flow rate of permeated fluid as a fraction of the combined mass flow rate of gas and permeated fluid is used to calculate the permeance of the material. The material test sample may be a sheet, a tube, or a solid shape. Operational test conditions may be varied, including concentration of the fluid, temperature of the fluid, strain profile of the material test sample, and differential pressure across the material test sample.

  18. The Technology of Measurement Feedback Systems.

    PubMed

    Bickman, Leonard; Kelley, Susan Douglas; Athay, Michele

    2012-12-01

    Usual care in the community is far from optimal. Sufficient evidence exists that dropout rates are significant, treatment is effective for only a small proportion of clients, and that the translation of evidence-based treatments to the real world is problematic. Technology has been shown to be helpful in health care in improving the effectiveness of treatment. A relatively new technology being used in mental health is measurement feedback systems (MFSs). MFSs are particularly applicable to couple and family psychology (CFP) because of its ability to provide information on the multiple perspectives involved in treatment. The Contextualized Feedback Systems(tm) (CFS®), developed at Vanderbilt University is used as an example of what can be accomplished with an MFS. The advantages and limitations of this technology are described as well as the anticipated reimbursement requirements that mental health services will need.

  19. Spectrometer system for optical reflectance measurements

    NASA Technical Reports Server (NTRS)

    Soller, Babs R. (Inventor); Phillipps, Patrick G. (Inventor); Parker, Michael S. (Inventor)

    2007-01-01

    A spectrometer system includes a thermal light source for illuminating a sample, where the thermal light source includes a filament that emits light when heated. The system additionally includes a spectrograph for measuring a light spectrum from the sample and an electrical circuit for supplying electrical current to the filament to heat the filament and for controlling a resistance of the filament. The electrical circuit includes a power supply that supplies current to the filament, first electrical components that sense a current through the filament, second electrical components that sense a voltage drop across the filament, third electrical components that compare a ratio of the sensed voltage drop and the sensed current with a predetermined value, and fourth electrical components that control the current through the filament or the voltage drop across the filament to cause the ratio to equal substantially the predetermined value.

  20. Seafloor earthquake measurement system, SEMS IV

    SciTech Connect

    Platzbecker, M.R.; Ehasz, J.P.; Franco, R.J.

    1997-07-01

    Staff of the Telemetry Technology Development Department (2664) have, in support of the U.S. Interior Department Mineral Management Services (MMS), developed and deployed the Seafloor Earthquake Measurement System IV (SEMS IV). The result of this development project is a series of three fully operational seafloor seismic monitor systems located at offshore platforms: Eureka, Grace, and Irene. The instrument probes are embedded from three to seven feet into the seafloor and hardwired to seismic data recorders installed top side at the offshore platforms. The probes and underwater cables were designed to survive the seafloor environment with an operation life of five years. The units have been operational for two years and have produced recordings of several minor earthquakes in that time. Sandia Labs will transfer operation of SEMS IV to MMS contractors in the coming months. 29 figs., 25 tabs.

  1. UCMS - A new signal parameter measurement system using digital signal processing techniques. [User Constraint Measurement System

    NASA Technical Reports Server (NTRS)

    Choi, H. J.; Su, Y. T.

    1986-01-01

    The User Constraint Measurement System (UCMS) is a hardware/software package developed by NASA Goddard to measure the signal parameter constraints of the user transponder in the TDRSS environment by means of an all-digital signal sampling technique. An account is presently given of the features of UCMS design and of its performance capabilities and applications; attention is given to such important aspects of the system as RF interface parameter definitions, hardware minimization, the emphasis on offline software signal processing, and end-to-end link performance. Applications to the measurement of other signal parameters are also discussed.

  2. UCMS - A new signal parameter measurement system using digital signal processing techniques. [User Constraint Measurement System

    NASA Technical Reports Server (NTRS)

    Choi, H. J.; Su, Y. T.

    1986-01-01

    The User Constraint Measurement System (UCMS) is a hardware/software package developed by NASA Goddard to measure the signal parameter constraints of the user transponder in the TDRSS environment by means of an all-digital signal sampling technique. An account is presently given of the features of UCMS design and of its performance capabilities and applications; attention is given to such important aspects of the system as RF interface parameter definitions, hardware minimization, the emphasis on offline software signal processing, and end-to-end link performance. Applications to the measurement of other signal parameters are also discussed.

  3. Multichannel hybrid system for neuromagnetic measurements.

    PubMed

    Foglietti, V; Del Gratta, C; Pasquarelli, A; Pizzella, V; Torrioli, G; Romani, G L; Gallagher, W J; Ketchen, M B; Kleinsasser, A W; Sandstrom, R L

    1991-01-01

    This paper describes progress toward the development of a 28-multichannel system for neuromagnetic measurements. A novel 'hybrid' design consisting of 16 first-order axial gradiometers and 12 first-order planar gradiometers was chosen, which optimises the use of the available cylindrical volume of the dewar tail. This configuration maintains the symmetry of the detected pattern with respect to rotation of a biomagnetic source located under the centre of the array and features a localisation power considerably better than an array of all first-order planar gradiometers. The detecting array permits simultaneous magnetic measurements over a circular scalp region of 16 cm diameter. The magnetic sensors used are Nb/PbAuIn DC SQUIDs fabricated at the IBM. The devices incorporate resonant damping resistors shunting the inductance, resulting in smooth flux-voltage characteristics and, consequently, very low noise figures in a flux-locked loop configuration. A simple and low cost electronic system has been designed and fabricated for the DC SQUID sensors.

  4. System for absolute measurements by interferometric sensors

    NASA Astrophysics Data System (ADS)

    Norton, Douglas A.

    1993-03-01

    The most common problem of interferometric sensors is their inability to measure absolute path imbalance. Presented in this paper is a signal processing system that gives absolute, unambiguous reading of optical path difference for almost any style of interferometric sensor. Key components are a wide band (incoherent) optical source, a polychromator, and FFT electronics. Advantages include no moving parts in the signal processor, no active components at the sensor location, and the use of standard single mode fiber for sensor illumination and signal transmission. Actual absolute path imbalance of the interferometer is determined without using fringe counting or other inferential techniques. The polychromator extracts the interference information that occurs at each discrete wavelength within the spectral band of the optical source. The signal processing consists of analog and digital filtering, Fast Fourier analysis, and a peak detection and interpolation algorithm. This system was originally designed for use in a remote pressure sensing application that employed a totally passive fiber optic interferometer. A performance qualification was made using a Fabry-Perot interferometer and a commercially available laser interferometer to measure the reference displacement.

  5. Behavioral System Feedback Measurement Failure: Sweeping Quality under the Rug

    ERIC Educational Resources Information Center

    Mihalic, Maria T.; Ludwig, Timothy D.

    2009-01-01

    Behavioral Systems rely on valid measurement systems to manage processes and feedback and to deliver contingencies. An examination of measurement system components designed to track customer service quality of furniture delivery drivers revealed the measurement system failed to capture information it was designed to measure. A reason for this…

  6. Behavioral System Feedback Measurement Failure: Sweeping Quality under the Rug

    ERIC Educational Resources Information Center

    Mihalic, Maria T.; Ludwig, Timothy D.

    2009-01-01

    Behavioral Systems rely on valid measurement systems to manage processes and feedback and to deliver contingencies. An examination of measurement system components designed to track customer service quality of furniture delivery drivers revealed the measurement system failed to capture information it was designed to measure. A reason for this…

  7. 39 CFR 3055.4 - Internal measurement systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 39 Postal Service 1 2012-07-01 2012-07-01 false Internal measurement systems. 3055.4 Section 3055... SATISFACTION REPORTING Annual Reporting of Service Performance Achievements § 3055.4 Internal measurement systems. Service performance measurements obtained from internal measurement systems or hybrid measurement...

  8. 39 CFR 3055.4 - Internal measurement systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 39 Postal Service 1 2013-07-01 2013-07-01 false Internal measurement systems. 3055.4 Section 3055... SATISFACTION REPORTING Annual Reporting of Service Performance Achievements § 3055.4 Internal measurement systems. Service performance measurements obtained from internal measurement systems or hybrid measurement...

  9. Measurement and Controls Data Acquisition System

    NASA Technical Reports Server (NTRS)

    Hall, Rick; Daniel, Alice; Batts, Frank E., Sr.

    2006-01-01

    Measurement and Controls Data Acquisition System (MCDAS) is an application program that integrates the functions of two stand-alone programs: one for acquisition of data, the other for controls. MCDAS facilitates and improves testing of complex engineering systems by helping to perform calibration and setup of test systems and acquisition, dissemination, and processing of data. Features of MCDAS include an intuitive, user-friendly graphical user interface, a capability for acquiring data at rates greater than previously possible, cooperation between the data-acquisition software subsystem and alarm-checking and analytical components of the control software subsystem, and a capability for dissemination of data through fiber optics and virtual and wide-area networks, including networks that contain hand-held display units. The integration of the data acquisition and control software offers a safety advantage by making alarm information available to the control software in a more timely manner. By enabling the use of hand-held devices, MCDAS reduces the time spent by technicians asking for screen updates to determine effects of setup actions. Previously recorded data can be processed without interruption to current acquisition of data. Analysts can continue to view test parameters while test-data files are being generated.

  10. 48 CFR 1401.7001-4 - Acquisition performance measurement systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Acquisition performance measurement systems. 1401.7001-4 Section 1401.7001-4 Federal Acquisition Regulations System DEPARTMENT OF THE... Acquisition performance measurement systems. (a) The acquisition performance measurement system is a three...

  11. 10 CFR 600.306 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Metric system of measurement. 600.306 Section 600.306... system of measurement. (a) The Metric Conversion Act of 1975, as amended by the Omnibus Trade and... system is the preferred measurement system for U.S. trade and commerce. (2) The metric system of...

  12. 10 CFR 600.306 - Metric system of measurement.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Metric system of measurement. 600.306 Section 600.306... system of measurement. (a) The Metric Conversion Act of 1975, as amended by the Omnibus Trade and... system is the preferred measurement system for U.S. trade and commerce. (2) The metric system of...

  13. 10 CFR 600.306 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Metric system of measurement. 600.306 Section 600.306... system of measurement. (a) The Metric Conversion Act of 1975, as amended by the Omnibus Trade and... system is the preferred measurement system for U.S. trade and commerce. (2) The metric system of...

  14. 10 CFR 600.306 - Metric system of measurement.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Metric system of measurement. 600.306 Section 600.306... system of measurement. (a) The Metric Conversion Act of 1975, as amended by the Omnibus Trade and... system is the preferred measurement system for U.S. trade and commerce. (2) The metric system of...

  15. 10 CFR 600.306 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Metric system of measurement. 600.306 Section 600.306... system of measurement. (a) The Metric Conversion Act of 1975, as amended by the Omnibus Trade and... system is the preferred measurement system for U.S. trade and commerce. (2) The metric system of...

  16. 48 CFR 1401.7001-4 - Acquisition performance measurement systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Acquisition performance measurement systems. 1401.7001-4 Section 1401.7001-4 Federal Acquisition Regulations System DEPARTMENT OF THE... Acquisition performance measurement systems. (a) The acquisition performance measurement system is a...

  17. 48 CFR 1401.7001-4 - Acquisition performance measurement systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Acquisition performance measurement systems. 1401.7001-4 Section 1401.7001-4 Federal Acquisition Regulations System DEPARTMENT OF THE... Acquisition performance measurement systems. (a) The acquisition performance measurement system is a three...

  18. Extreme Low Frequency Acoustic Measurement System

    NASA Technical Reports Server (NTRS)

    Shams, Qamar A. (Inventor); Zuckerwar, Allan J. (Inventor)

    2017-01-01

    The present invention is an extremely low frequency (ELF) microphone and acoustic measurement system capable of infrasound detection in a portable and easily deployable form factor. In one embodiment of the invention, an extremely low frequency electret microphone comprises a membrane, a backplate, and a backchamber. The backchamber is sealed to allow substantially no air exchange between the backchamber and outside the microphone. Compliance of the membrane may be less than ambient air compliance. The backplate may define a plurality of holes and a slot may be defined between an outer diameter of the backplate and an inner wall of the microphone. The locations and sizes of the holes, the size of the slot, and the volume of the backchamber may be selected such that membrane motion is substantially critically damped.

  19. Extreme low frequency acoustic measurement system

    NASA Technical Reports Server (NTRS)

    Shams, Qamar A. (Inventor); Zuckerwar, Allan J. (Inventor)

    2013-01-01

    The present invention is an extremely low frequency (ELF) microphone and acoustic measurement system capable of infrasound detection in a portable and easily deployable form factor. In one embodiment of the invention, an extremely low frequency electret microphone comprises a membrane, a backplate, and a backchamber. The backchamber is sealed to allow substantially no air exchange between the backchamber and outside the microphone. Compliance of the membrane may be less than ambient air compliance. The backplate may define a plurality of holes and a slot may be defined between an outer diameter of the backplate and an inner wall of the microphone. The locations and sizes of the holes, the size of the slot, and the volume of the backchamber may be selected such that membrane motion is substantially critically damped.

  20. Units of measure in clinical information systems.

    PubMed

    Schadow, G; McDonald, C J; Suico, J G; Föhring, U; Tolxdorff, T

    1999-01-01

    The authors surveyed existing standard codes for units of measures, such as ISO 2955, ANSI X3.50, and Health Level 7's ISO+. Because these standards specify only the character representation of units, the authors developed a semantic model for units based on dimensional analysis. Through this model, conversion between units and calculations with dimensioned quantities become as simple as calculating with numbers. All atomic symbols for prefixes and units are defined in one small table. Huge permutated conversion tables are not required. This method is also simple enough to be widely implementable in today's information systems. To promote the application of the method the authors provide an open-source implementation of this method in JAVA. All existing code standards for units, however, are incomplete for practical use and require substantial changes to correct their many ambiguities. The authors therefore developed a code for units that is much more complete and free from ambiguities.

  1. Dynamic gas temperature measurement system, volume 1

    NASA Technical Reports Server (NTRS)

    Elmore, D. L.; Robinson, W. W.; Watkins, W. B.

    1983-01-01

    A gas temperature measurement system with compensated frequency response of 1 kHz and capability to operate in the exhaust of a gas turbine engine combustor was developed. A review of available technologies which could attain this objective was done. The most promising method was identified as a two wire thermocouple, with a compensation method based on the responses of the two different diameter thermocouples to the fluctuating gas temperature field. In a detailed design of the probe, transient conduction effects were identified as significant. A compensation scheme was derived to include the effects of gas convection and wire conduction. The two wire thermocouple concept was tested in a laboratory burner exhaust to temperatures of about 3000 F and in a gas turbine engine to combustor exhaust temperatures of about 2400 F. Uncompensated and compensated waveforms and compensation spectra are presented.

  2. Units of Measure in Clinical Information Systems

    PubMed Central

    Schadow, Gunther; McDonald, Clement J.; Suico, Jeffrey G.; Föhring, Ulrich; Tolxdorff, Thomas

    1999-01-01

    The authors surveyed existing standard codes for units of measures, such as ISO 2955, ANSI ×3.50, and Health Level 7′s ISO+. Because these standards specify only the character representation of units, the authors developed a semantic model for units based on dimensional analysis. Through this model, conversion between units and calculations with dimensioned quantities become as simple as calculating with numbers. All atomic symbols for prefixes and units are defined in one small table. Huge permutated conversion tables are not required. This method is also simple enough to be widely implementable in today's information systems. To promote the application of the method the authors provide an open-source implementation of this method in JAVA. All existing code standards for units, however, are incomplete for practical use and require substantial changes to correct their many ambiguities. The authors therefore developed a code for units that is much more complete and free from ambiguities. PMID:10094068

  3. A new ultrasonic stride length measuring system.

    PubMed

    Maki, Hiromichi; Ogawa, Hidekuni; Yonezawa, Yoshiharu; Hahn, Allen W; Caldwell, W Morton

    2012-01-01

    We have developed a new ultrasonic stride length measuring system for analyzing the human gait. An ultrasonic transmitter, a radio transmitter, a pressure sensor and microcontroller are attached to the subject’s heel on the right shoe and in the direction of the left shoe. Two ultrasonic receivers, a radio receiver, a microcontroller and a 1GB SD memory card are installed on the left shoe. Ultrasonic receivers are attached to the toe and heel, in the direction of the right shoe. When the right foot contacts the ground, its heel-mounted ultrasonic and radio transmitters simultaneously transmit to the left shoe. However, radio propagation velocity is far faster than ultrasonic velocity. Therefore, the radio wave acts as a start signal to the radio receiver of the left shoe, indicating the start of ultrasound transmission from the right shoe. Upon receiving the start signal, the microcontroller timer starts to measure each ultrasound propagation time from the right shoe to the left shoe. Distance between right and left shoes is calculated with the time and ultrasound velocity and stored in the SD memory card. Stride length is calculated with a cosine function, by using the obtained distances and the distance between the toe and heel of the left shoe, by a conventional computer. The stride length can then be used for many characterizations of the subject’s gait.

  4. SNR Degradation in Undersampled Phase Measurement Systems

    PubMed Central

    Salido-Monzú, David; Meca-Meca, Francisco J.; Martín-Gorostiza, Ernesto; Lázaro-Galilea, José L.

    2016-01-01

    A wide range of measuring applications rely on phase estimation on sinusoidal signals. These systems, where the estimation is mainly implemented in the digital domain, can generally benefit from the use of undersampling to reduce the digitizer and subsequent digital processing requirements. This may be crucial when the application characteristics necessarily imply a simple and inexpensive sensor. However, practical limitations related to the phase stability of the band-pass filter prior digitization establish restrictions to the reduction of noise bandwidth. Due to this, the undersampling intensity is practically defined by noise aliasing, taking into account the amount of signal-to-noise ratio (SNR) reduction caused by it considering the application accuracy requirements. This work analyzes the relationship between undersampling frequency and SNR reduction, conditioned by the stability requirements of the filter that defines the noise bandwidth before digitization. The effect of undersampling is quantified in a practical situation where phase differences are measured by in-phase and quadrature (I/Q) demodulation for an infrared ranging application. PMID:27783033

  5. SNR Degradation in Undersampled Phase Measurement Systems.

    PubMed

    Salido-Monzú, David; Meca-Meca, Francisco J; Martín-Gorostiza, Ernesto; Lázaro-Galilea, José L

    2016-10-24

    A wide range of measuring applications rely on phase estimation on sinusoidal signals. These systems, where the estimation is mainly implemented in the digital domain, can generally benefit from the use of undersampling to reduce the digitizer and subsequent digital processing requirements. This may be crucial when the application characteristics necessarily imply a simple and inexpensive sensor. However, practical limitations related to the phase stability of the band-pass filter prior digitization establish restrictions to the reduction of noise bandwidth. Due to this, the undersampling intensity is practically defined by noise aliasing, taking into account the amount of signal-to-noise ratio (SNR) reduction caused by it considering the application accuracy requirements. This work analyzes the relationship between undersampling frequency and SNR reduction, conditioned by the stability requirements of the filter that defines the noise bandwidth before digitization. The effect of undersampling is quantified in a practical situation where phase differences are measured by in-phase and quadrature (I/Q) demodulation for an infrared ranging application.

  6. An objective system for measuring facial attractiveness.

    PubMed

    Bashour, Mounir

    2006-09-01

    Research over the past 20 years has shown that judgments of facial attractiveness are universal; people from all cultures and backgrounds rank and rate faces for attractiveness the same. As such a model for objectively rating facial attractiveness is theoretically plausible, if designed, it would have many uses, including outcomes analysis in plastic surgery of the face. The authors tested a schematic facial composite/prototype mathematical model (the phi mask created by Dr. Stephen Marquardt) as a method for measuring facial attractiveness in an objective manner. Thirty-seven male and 35 female faces of 18- to 30-year-old whites of European extraction were rated, as were 31 composite faces of each sex using both Internet and direct survey judges. The faces were tested against the phi mask model analyzing deviations of facial anthropometric points from corresponding phi mask nodal points using equivalent weightings, and weightings arrived at by way of multiple linear regression. The deviation from the phi mask significantly correlates with attractiveness, explaining from 25 to 75 percent of the variance in attractiveness judgments, depending on the methodology used. The phi mask model supports averageness or prototypicality of the face as being the major component of the facial attractiveness gestalt and is a first step in producing an objective system for measuring facial attractiveness.

  7. Method of measurement in biological systems

    DOEpatents

    Turteltaub, Kenneth W.; Vogel, John S.; Felton, James S.; Gledhill, Barton L.; Davis, Jay C.; Stanker, Larry H.

    1993-05-11

    Disclosed is a method of quantifying molecules in biological substances, comprising: a. selecting a biological host in which radioisotopes are present in concentrations equal to or less than those in the ambient biosphere, b. preparing a long-lived radioisotope labeled reactive chemical specie, c. administering said chemical specie to said biological host in doses sufficiently low to avoid significant overt damage to the biological system thereof, d. allowing a period of time to elapse sufficient for dissemination and interaction of said chemical specie with said host throughout said biological system of said host, e. isolating a reacted fraction of the biological substance from said host in a manner sufficient to avoid contamination of said substance from extraneous sources, f. converting said fraction of biological substance by suitable means to a material which efficiently produces charged ions in at least one of several possible ion sources without introduction of significant isotopic fractionation, and, g. measuring the radioisotope concentration in said material by means of direct isotopic counting.

  8. Method of measurement in biological systems

    DOEpatents

    Turteltaub, Kenneth W.; Vogel, John S.; Felton, James S.; Gledhill, Barton L.; Davis, Jay C.

    1994-01-01

    Disclosed is a method of quantifying molecules in biological substances comprising: a. selecting a biological host in which radioisotopes are present in concentrations equal to or less than those in the ambient biosphere, b. preparing a long-lived radioisotope labeled reactive chemical specie, c. administering said chemical specie to said biological host in doses sufficiently low to avoid significant overt damage to the biological system thereof, d. allowing a period of time to elapse sufficient for dissemination and interaction of said chemical specie with said host throughout said biological system of said host, e. isolating a reacted fraction of the biological substance from said host in a manner sufficient to avoid contamination of said substance from extraneous sources, f. converting said fraction of biological substance by suitable means to a material which efficiently produces charged ions in at least one of several possible ion sources without introduction of significant isotopic fractionation, and, g. measuring the radioisotope concentration in said material by means of direct isotopic counting.

  9. Method of measurement in biological systems

    DOEpatents

    Turteltaub, K.W.; Vogel, J.S.; Felton, J.S.; Gledhill, B.L.; Davis, J.C.

    1994-12-27

    Disclosed is a method of quantifying molecules in biological substances comprising: a. selecting a biological host in which radioisotopes are present in concentrations equal to or less than those in the ambient biosphere, b. preparing a long-lived radioisotope labeled reactive chemical specie, c. administering the chemical specie to the biological host in doses sufficiently low to avoid significant overt damage to the biological system, d. allowing a period of time to elapse sufficient for dissemination and interaction of the chemical specie with the host throughout the biological system of the host, e. isolating a reacted fraction of the biological substance from the host in a manner sufficient to avoid contamination of the substance from extraneous sources, f. converting the fraction of biological substance by suitable means to a material which efficiently produces charged ions in at least one of several possible ion sources without introduction of significant isotopic fractionation, and, g. measuring the radioisotope concentration in the material by means of direct isotopic counting. 5 figures.

  10. Hydrostatic levelling systems: Measuring at the system limits

    NASA Astrophysics Data System (ADS)

    Meier, Edi; Geiger, Alain; Ingensand, Hilmar; Licht, Hans; Limpach, Philippe; Steiger, Andreas; Zwyssig, Roger

    2010-09-01

    Three hydrostatic displacement monitoring system applications in Switzerland are discussed; the first concerns experience gained monitoring the foundation of the Albigna dam, the second relating to the underground stability of the Swiss Light Source synchrotron and the third concerning the deformation of a bridge near the city of Lucerne. Two different principles were applied, the Hydrostatic Levelling System (HLS) using the “half-filled pipe principle” developed by the Paul Scherrer Institute and the Large Area Settlement System (LAS) using the “differential pressure principle”. With both systems ground deformations induced by tidal forces can be seen. However, high accuracy of single sensors is not sufficient. A well-designed configuration of the complete system is equally important. On the other hand there are also limits imposed by installation logistics and by the environmental conditions. An example is the bridge monitoring application, where the acceleration along the bridge due to the passage of heavy trucks limits the feasibility of using hydrostatic levelling measurements.

  11. Turbulence Measurements by the DC-8 Meteorological Measurement System

    NASA Technical Reports Server (NTRS)

    Chan, K. R.; Dean-Day, J.; Bowen, S. W.; Bui, T. P.; Chan, K. Roland (Technical Monitor)

    1997-01-01

    The instrumentation of a new MMS on the DC-8 aircraft is briefly described. Methods to compute and evaluate the turbulent dissipation rate epsilon, based on theory and MMS data, are discussed. Examples of turbulence measurements during encounters of a wake vortex, wave clouds, persistent contrails, mountain are gravity waves are illustrated.

  12. 21 CFR 890.1600 - Intermittent pressure measurement system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Intermittent pressure measurement system. 890.1600... Intermittent pressure measurement system. (a) Identification. An intermittent pressure measurement system is an evaluative device intended for medical purposes, such as to measure the actual pressure between the...

  13. 21 CFR 890.1600 - Intermittent pressure measurement system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Intermittent pressure measurement system. 890.1600... Intermittent pressure measurement system. (a) Identification. An intermittent pressure measurement system is an evaluative device intended for medical purposes, such as to measure the actual pressure between the...

  14. Wing tip vortex measurements with laser Doppler systems

    NASA Technical Reports Server (NTRS)

    Fuller, C. E., III

    1973-01-01

    The vortex velocity field produced by a rectangular wing in a subsonic wind tunnel was measured using two laser Doppler velocimeter systems. One system made three dimensional mean velocity measurements and the other made one dimensional turbulence measurements. The systems and test procedures are described and comparisons of the measurements are made. The data defined a strong spiral motion in the vortex formation process.

  15. 21 CFR 876.1620 - Urodynamics measurement system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Urodynamics measurement system. 876.1620 Section... measurement system. (a) Identification. A urodynamics measurement system is a device used to measure volume and pressure in the urinary bladder when it is filled through a catheter with carbon dioxide or water...

  16. Free-form surface measuring method based on optical theodolite measuring system

    NASA Astrophysics Data System (ADS)

    Yu, Caili

    2012-10-01

    The measurement for single-point coordinate, length and large-dimension curved surface in industrial measurement can be achieved through forward intersection measurement by the theodolite measuring system composed of several optical theodolites and one computer. The measuring principle of flexible large-dimension three-coordinate measuring system made up of multiple (above two) optical theodolites and composition and functions of the system have been introduced in this paper. Especially for measurement of curved surface, 3D measured data of spatial free-form surface is acquired through the theodolite measuring system and the CAD model is formed through surface fitting to directly generate CAM processing data.

  17. 45 CFR 74.15 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 45 Public Welfare 1 2012-10-01 2012-10-01 false Metric system of measurement. 74.15 Section 74.15... ORGANIZATIONS, AND COMMERCIAL ORGANIZATIONS Pre-Award Requirements § 74.15 Metric system of measurement. The... that the metric system is the preferred measurement system for U.S. trade and commerce. The Act...

  18. 28 CFR 70.15 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Metric system of measurement. 70.15... AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 70.15 Metric system of measurement. The... that the metric system is the preferred measurement system for U.S. trade and commerce. The Act...

  19. 36 CFR 1210.15 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Metric system of measurement... system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S. trade and...

  20. 14 CFR 1260.115 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 5 2012-01-01 2012-01-01 false Metric system of measurement. 1260.115....115 Metric system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S...

  1. 22 CFR 145.15 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Metric system of measurement. 145.15 Section... system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S. trade and...

  2. 45 CFR 2543.15 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 45 Public Welfare 4 2013-10-01 2013-10-01 false Metric system of measurement. 2543.15 Section 2543...-PROFIT ORGANIZATIONS Pre-Award Requirements § 2543.15 Metric system of measurement. The Metric Conversion... system is the preferred measurement system for U.S. trade and commerce. The Act requires each Federal...

  3. 20 CFR 435.15 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 20 Employees' Benefits 2 2013-04-01 2013-04-01 false Metric system of measurement. 435.15 Section..., AND COMMERCIAL ORGANIZATIONS Pre-Award Requirements § 435.15 Metric system of measurement. The Metric... metric system is the preferred measurement system for U.S. trade and commerce. The Act requires each...

  4. 32 CFR 22.530 - Metric system of measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 1 2014-07-01 2014-07-01 false Metric system of measurement. 22.530 Section 22... CFR, 1991 Comp., p. 343), states that: (1) The metric system is the preferred measurement system for U.S. trade and commerce. (2) The metric system of measurement will be used, to the extent economically...

  5. 34 CFR 74.15 - Metric system of measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 34 Education 1 2011-07-01 2011-07-01 false Metric system of measurement. 74.15 Section 74.15... Metric system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S...

  6. 32 CFR 32.15 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Metric system of measurement. 32.15 Section 32..., HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 32.15 Metric system of measurement...) declares that the metric system is the preferred measurement system for U.S. trade and commerce, and for...

  7. 22 CFR 226.15 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 22 Foreign Relations 1 2013-04-01 2013-04-01 false Metric system of measurement. 226.15 Section....S. NON-GOVERNMENTAL ORGANIZATIONS Pre-award Requirements § 226.15 Metric system of measurement. (a...) declares that the metric system is the preferred measurement system for U.S. trade and commerce. (b...

  8. 40 CFR 30.15 - Metric system of measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 1 2014-07-01 2014-07-01 false Metric system of measurement. 30.15...), declares that the metric system is the preferred measurement system for U.S. trade and commerce. The Act..., when the metric system of measurement will be used in the agency's procurements, grants, and other...

  9. 2 CFR 215.15 - Metric system of measurement.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 2 Grants and Agreements 1 2011-01-01 2011-01-01 false Metric system of measurement. 215.15 Section... ORGANIZATIONS (OMB CIRCULAR A-110) Pre-Award Requirements § 215.15 Metric system of measurement. The Metric... metric system is the preferred measurement system for U.S. trade and commerce. The Act requires each...

  10. 22 CFR 145.15 - Metric system of measurement.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 22 Foreign Relations 1 2014-04-01 2014-04-01 false Metric system of measurement. 145.15 Section... system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S. trade and...

  11. 28 CFR 70.15 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Metric system of measurement. 70.15... AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 70.15 Metric system of measurement. The... that the metric system is the preferred measurement system for U.S. trade and commerce. The Act...

  12. 32 CFR 22.530 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 1 2012-07-01 2012-07-01 false Metric system of measurement. 22.530 Section 22... CFR, 1991 Comp., p. 343), states that: (1) The metric system is the preferred measurement system for U.S. trade and commerce. (2) The metric system of measurement will be used, to the extent economically...

  13. 20 CFR 435.15 - Metric system of measurement.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 2 2011-04-01 2011-04-01 false Metric system of measurement. 435.15 Section..., AND COMMERCIAL ORGANIZATIONS Pre-Award Requirements § 435.15 Metric system of measurement. The Metric... metric system is the preferred measurement system for U.S. trade and commerce. The Act requires each...

  14. 20 CFR 435.15 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 20 Employees' Benefits 2 2012-04-01 2012-04-01 false Metric system of measurement. 435.15 Section..., AND COMMERCIAL ORGANIZATIONS Pre-Award Requirements § 435.15 Metric system of measurement. The Metric... metric system is the preferred measurement system for U.S. trade and commerce. The Act requires each...

  15. 22 CFR 226.15 - Metric system of measurement.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 22 Foreign Relations 1 2014-04-01 2014-04-01 false Metric system of measurement. 226.15 Section....S. NON-GOVERNMENTAL ORGANIZATIONS Pre-award Requirements § 226.15 Metric system of measurement. (a...) declares that the metric system is the preferred measurement system for U.S. trade and commerce. (b...

  16. 34 CFR 74.15 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Metric system of measurement. 74.15 Section 74.15... Metric system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S...

  17. 28 CFR 70.15 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Metric system of measurement. 70.15... AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 70.15 Metric system of measurement. The... that the metric system is the preferred measurement system for U.S. trade and commerce. The Act...

  18. 7 CFR 3019.15 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 15 2012-01-01 2012-01-01 false Metric system of measurement. 3019.15 Section 3019.15... system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S. trade and...

  19. 7 CFR 3019.15 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 15 2013-01-01 2013-01-01 false Metric system of measurement. 3019.15 Section 3019.15... system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S. trade and...

  20. 41 CFR 105-72.205 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S. trade and... Secretary of Commerce, when the metric system of measurement will be used in the agency's procurements...

  1. 34 CFR 74.15 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 34 Education 1 2013-07-01 2013-07-01 false Metric system of measurement. 74.15 Section 74.15... Metric system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S...

  2. 15 CFR 14.15 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 15 Commerce and Foreign Trade 1 2013-01-01 2013-01-01 false Metric system of measurement. 14.15... COMMERCIAL ORGANIZATIONS Pre-Award Requirements § 14.15 Metric system of measurement. The Metric Conversion... system is the preferred measurement system for U.S. trade and commerce. The Act requires each Federal...

  3. 7 CFR 3019.15 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Metric system of measurement. 3019.15 Section 3019.15... system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S. trade and...

  4. 24 CFR 84.15 - Metric system of measurement.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 1 2011-04-01 2011-04-01 false Metric system of measurement. 84.15...) declares that the metric system is the preferred measurement system for U.S. trade and commerce. The Act..., when the metric system of measurement will be used in the agency's procurements, grants, and other...

  5. 22 CFR 145.15 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 22 Foreign Relations 1 2013-04-01 2013-04-01 false Metric system of measurement. 145.15 Section... system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S. trade and...

  6. 24 CFR 84.15 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 1 2013-04-01 2013-04-01 false Metric system of measurement. 84.15...) declares that the metric system is the preferred measurement system for U.S. trade and commerce. The Act..., when the metric system of measurement will be used in the agency's procurements, grants, and other...

  7. 24 CFR 84.15 - Metric system of measurement.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 1 2014-04-01 2014-04-01 false Metric system of measurement. 84.15...) declares that the metric system is the preferred measurement system for U.S. trade and commerce. The Act..., when the metric system of measurement will be used in the agency's procurements, grants, and other...

  8. 15 CFR 14.15 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 15 Commerce and Foreign Trade 1 2012-01-01 2012-01-01 false Metric system of measurement. 14.15... COMMERCIAL ORGANIZATIONS Pre-Award Requirements § 14.15 Metric system of measurement. The Metric Conversion... system is the preferred measurement system for U.S. trade and commerce. The Act requires each Federal...

  9. 45 CFR 74.15 - Metric system of measurement.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 45 Public Welfare 1 2011-10-01 2011-10-01 false Metric system of measurement. 74.15 Section 74.15... ORGANIZATIONS, AND COMMERCIAL ORGANIZATIONS Pre-Award Requirements § 74.15 Metric system of measurement. The... that the metric system is the preferred measurement system for U.S. trade and commerce. The Act...

  10. 22 CFR 226.15 - Metric system of measurement.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 22 Foreign Relations 1 2011-04-01 2011-04-01 false Metric system of measurement. 226.15 Section....S. NON-GOVERNMENTAL ORGANIZATIONS Pre-award Requirements § 226.15 Metric system of measurement. (a...) declares that the metric system is the preferred measurement system for U.S. trade and commerce. (b...

  11. 20 CFR 435.15 - Metric system of measurement.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 20 Employees' Benefits 2 2014-04-01 2014-04-01 false Metric system of measurement. 435.15 Section..., AND COMMERCIAL ORGANIZATIONS Pre-Award Requirements § 435.15 Metric system of measurement. The Metric... metric system is the preferred measurement system for U.S. trade and commerce. The Act requires each...

  12. 32 CFR 32.15 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 1 2013-07-01 2013-07-01 false Metric system of measurement. 32.15 Section 32..., HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 32.15 Metric system of measurement...) declares that the metric system is the preferred measurement system for U.S. trade and commerce, and for...

  13. 24 CFR 84.15 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 1 2012-04-01 2012-04-01 false Metric system of measurement. 84.15...) declares that the metric system is the preferred measurement system for U.S. trade and commerce. The Act..., when the metric system of measurement will be used in the agency's procurements, grants, and other...

  14. 32 CFR 32.15 - Metric system of measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 1 2014-07-01 2014-07-01 false Metric system of measurement. 32.15 Section 32..., HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 32.15 Metric system of measurement...) declares that the metric system is the preferred measurement system for U.S. trade and commerce, and for...

  15. 41 CFR 105-72.205 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S. trade and... Secretary of Commerce, when the metric system of measurement will be used in the agency's procurements...

  16. 32 CFR 22.530 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Metric system of measurement. 22.530 Section 22... CFR, 1991 Comp., p. 343), states that: (1) The metric system is the preferred measurement system for U.S. trade and commerce. (2) The metric system of measurement will be used, to the extent economically...

  17. 36 CFR § 1210.15 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 36 Parks, Forests, and Public Property 3 2013-07-01 2012-07-01 true Metric system of measurement... system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S. trade and...

  18. 41 CFR 105-72.205 - Metric system of measurement.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S. trade and... Secretary of Commerce, when the metric system of measurement will be used in the agency's procurements...

  19. 22 CFR 226.15 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 22 Foreign Relations 1 2012-04-01 2012-04-01 false Metric system of measurement. 226.15 Section....S. NON-GOVERNMENTAL ORGANIZATIONS Pre-award Requirements § 226.15 Metric system of measurement. (a...) declares that the metric system is the preferred measurement system for U.S. trade and commerce. (b...

  20. 45 CFR 74.15 - Metric system of measurement.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 45 Public Welfare 1 2014-10-01 2014-10-01 false Metric system of measurement. 74.15 Section 74.15... ORGANIZATIONS, AND COMMERCIAL ORGANIZATIONS Pre-Award Requirements § 74.15 Metric system of measurement. The... that the metric system is the preferred measurement system for U.S. trade and commerce. The Act...

  1. 34 CFR 74.15 - Metric system of measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 34 Education 1 2014-07-01 2014-07-01 false Metric system of measurement. 74.15 Section 74.15... Metric system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S...

  2. 14 CFR 1260.115 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Metric system of measurement. 1260.115....115 Metric system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S...

  3. 2 CFR 215.15 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 2 Grants and Agreements 1 2013-01-01 2013-01-01 false Metric system of measurement. 215.15 Section... ORGANIZATIONS (OMB CIRCULAR A-110) Pre-Award Requirements § 215.15 Metric system of measurement. The Metric... metric system is the preferred measurement system for U.S. trade and commerce. The Act requires each...

  4. 45 CFR 74.15 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 45 Public Welfare 1 2013-10-01 2013-10-01 false Metric system of measurement. 74.15 Section 74.15... ORGANIZATIONS, AND COMMERCIAL ORGANIZATIONS Pre-Award Requirements § 74.15 Metric system of measurement. The... that the metric system is the preferred measurement system for U.S. trade and commerce. The Act...

  5. 28 CFR 70.15 - Metric system of measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Metric system of measurement. 70.15... AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 70.15 Metric system of measurement. The... that the metric system is the preferred measurement system for U.S. trade and commerce. The Act...

  6. 28 CFR 70.15 - Metric system of measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Metric system of measurement. 70.15... AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 70.15 Metric system of measurement. The... that the metric system is the preferred measurement system for U.S. trade and commerce. The Act...

  7. 36 CFR 1210.15 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 36 Parks, Forests, and Public Property 3 2012-07-01 2012-07-01 false Metric system of measurement... system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S. trade and...

  8. 32 CFR 32.15 - Metric system of measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 1 2011-07-01 2011-07-01 false Metric system of measurement. 32.15 Section 32..., HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 32.15 Metric system of measurement...) declares that the metric system is the preferred measurement system for U.S. trade and commerce, and for...

  9. 15 CFR 14.15 - Metric system of measurement.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 1 2011-01-01 2011-01-01 false Metric system of measurement. 14.15... COMMERCIAL ORGANIZATIONS Pre-Award Requirements § 14.15 Metric system of measurement. The Metric Conversion... system is the preferred measurement system for U.S. trade and commerce. The Act requires each Federal...

  10. 15 CFR 14.15 - Metric system of measurement.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 15 Commerce and Foreign Trade 1 2014-01-01 2014-01-01 false Metric system of measurement. 14.15... COMMERCIAL ORGANIZATIONS Pre-Award Requirements § 14.15 Metric system of measurement. The Metric Conversion... system is the preferred measurement system for U.S. trade and commerce. The Act requires each Federal...

  11. 22 CFR 145.15 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 22 Foreign Relations 1 2012-04-01 2012-04-01 false Metric system of measurement. 145.15 Section... system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S. trade and...

  12. 45 CFR 2543.15 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 45 Public Welfare 4 2012-10-01 2012-10-01 false Metric system of measurement. 2543.15 Section 2543...-PROFIT ORGANIZATIONS Pre-Award Requirements § 2543.15 Metric system of measurement. The Metric Conversion... system is the preferred measurement system for U.S. trade and commerce. The Act requires each Federal...

  13. 7 CFR 3019.15 - Metric system of measurement.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 15 2011-01-01 2011-01-01 false Metric system of measurement. 3019.15 Section 3019.15... system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S. trade and...

  14. 7 CFR 3019.15 - Metric system of measurement.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Metric system of measurement. 3019.15 Section 3019.15... system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S. trade and...

  15. 36 CFR 1210.15 - Metric system of measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Metric system of measurement... system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement system for U.S. trade and...

  16. 2 CFR 215.15 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 2 Grants and Agreements 1 2010-01-01 2010-01-01 false Metric system of measurement. 215.15 Section...) declares that the metric system is the preferred measurement system for U.S. trade and commerce. The Act..., when the metric system of measurement will be used in the agency's procurements, grants, and other...

  17. 32 CFR 22.530 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 1 2013-07-01 2013-07-01 false Metric system of measurement. 22.530 Section 22... CFR, 1991 Comp., p. 343), states that: (1) The metric system is the preferred measurement system for U.S. trade and commerce. (2) The metric system of measurement will be used, to the extent economically...

  18. 2 CFR 215.15 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 2 Grants and Agreements 1 2012-01-01 2012-01-01 false Metric system of measurement. 215.15 Section... ORGANIZATIONS (OMB CIRCULAR A-110) Pre-Award Requirements § 215.15 Metric system of measurement. The Metric... metric system is the preferred measurement system for U.S. trade and commerce. The Act requires each...

  19. 32 CFR 32.15 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 1 2012-07-01 2012-07-01 false Metric system of measurement. 32.15 Section 32..., HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 32.15 Metric system of measurement...) declares that the metric system is the preferred measurement system for U.S. trade and commerce, and for...

  20. 32 CFR 22.530 - Metric system of measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 1 2011-07-01 2011-07-01 false Metric system of measurement. 22.530 Section 22... CFR, 1991 Comp., p. 343), states that: (1) The metric system is the preferred measurement system for U.S. trade and commerce. (2) The metric system of measurement will be used, to the extent economically...

  1. 22 CFR 226.15 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Metric system of measurement. 226.15 Section....S. NON-GOVERNMENTAL ORGANIZATIONS Pre-award Requirements § 226.15 Metric system of measurement. (a...) declares that the metric system is the preferred measurement system for U.S. trade and commerce....

  2. High speed high dynamic range high accuracy measurement system

    SciTech Connect

    Deibele, Craig E.; Curry, Douglas E.; Dickson, Richard W.; Xie, Zaipeng

    2016-11-29

    A measuring system includes an input that emulates a bandpass filter with no signal reflections. A directional coupler connected to the input passes the filtered input to electrically isolated measuring circuits. Each of the measuring circuits includes an amplifier that amplifies the signal through logarithmic functions. The output of the measuring system is an accurate high dynamic range measurement.

  3. Toward a formal theory of the measuring system

    NASA Astrophysics Data System (ADS)

    Battista Rossi, Giovanni; Crenna, Francesco

    2016-11-01

    Measurement aims at obtaining a numerical description of objects/events/persons in real world by means of a measuring system. Measurement is widely used as a key way for obtaining high quality information from the real world. across disciplines. In the present day. there is growing consensus in holding that measurement is characterized by the use of something that qualifies as a “measuring system”. Therefore. we discuss sufficient conditions for an empirical system to qualify as a measuring system.

  4. Optical measurement system for characterizing plastic surfaces

    NASA Astrophysics Data System (ADS)

    Gahleitner, R.; Niel, Kurt S.; Frank, S.

    2008-02-01

    Injection molded plastic parts are often influenced with the surface defect tiger stripes, which dramatically reduce the visual quality. Tiger stripes are known as alternating bands of bright and dull regions normally to the molded flow direction. This defect highly depends on the injection time and on the formation of the plastic compound. In the last years, the intensity of the tiger stripes defect was controlled visually. For quantifying the tiger strip defect a new, efficient, repeatable, reliable and nondestructive optical measurement system is proposed. To evaluate the dependency of the injection time, a number of five DIN-A5 plastic specimens are molded. Each of the five plates consists of the same material but they have different injection times. For the measurement, one specimen is put into the specimen holder, which is placed on the drawer of a closed cabinet. In this inside black painted cabinet a LED light source and a CCD Camera are mounted. The beams of the LED light are diffuse reflected on the surface of the specimen. To catch only parallel beams by the lens of the camera a large distance between specimen and camera is realized by two justified mirrors in the cabinet. The bright and dull regions of the tiger stripe defect have different diffuse reflection parameters. Thus in a picture of defined brightness the visibility of this defect is very good. To enhance the repeatability the failure of the camera noise and of the light oscillation is reduced by mends of averaging multiple images. Next, the surface structure is filtered out of the image and a representing number of horizontal grey-value lines are extracted. The so called tiger line signal is the difference between the grey line and a calculated polynomial function (degree of 6) and shows the surface defect of each line oscillating on the zero x-axis. For each tiger line signal the mean squared error is evaluated. To calculate a quantitative value of the whole surface, all line errors are

  5. A new method of ICCD imaging system MRC measurement

    NASA Astrophysics Data System (ADS)

    Li, Sheng-cai; Jin, Wei-qi; Wang, Xia; Zhang, Wei-qiang; Dong, Hai-yan

    2005-02-01

    Based on analysis of the working principle of ICCD imaging system, the paper develops a new testing system for synthetic performance of ICCD imaging system. With the help of this testing system for integrative performance and the theory of Weibull psychometric function, a new method for MRC measurement of Space Light Modulation (SLM) is proposed, and the paper firstly implements measurement for minimum resolvable contrast performance of ICCD imaging system. The method provides reference for MRC performance measurement of other imaging system.

  6. Optical Reflection Measurement System Using A Swept Modulation Frequency Technique

    NASA Astrophysics Data System (ADS)

    Braun, David M.; Leyde, Kent W.

    1989-03-01

    A measurement system has been developed capable of mea-suring reflected optical power as low as 0.0025% with a spot size diam-eter of 24 Am. One application for this system is the characterization of small-area photodetectors. The operation of the measurement system is simple, allowing the operator to quickly make multiple reflection measurements, and it does not require a darkroom. The measurement system merges a microscope, for visual alignment and focusing of the laser beam, with a lightwave component analyzer using modulation vec-tor error correction. A measurement comparison between the analyzer-based system and a power-meter-based system showed that each sys-tem can measure reflections as low as 0.0025%. However, the analyzer-based system offers the advantage of identifying the location and magnitude of system reflections. The system operates at a wavelength of 1310 nm.

  7. The Galileo System of Measurement: Preliminary Evidence for Precision, Stability, and Equivalance to Traditional Measures

    ERIC Educational Resources Information Center

    Gillham, James; Woelfel, Joseph

    1977-01-01

    Describes the Galileo system of measurement operations including reliability and validity data. Illustrations of some of the relations between Galileo measures and traditional procedures are provided. (MH)

  8. A critical view of the 'social reinsertion' concept and its implications for the practice of psychologists in the area of mental health in the Brazilian Unified Health System (Sistema Único de Saúde).

    PubMed

    Frazatto, Carina F; Sawaia, Bader B

    2016-03-01

    Improving psychological practice in mental health services in the Brazilian Unified Health System (Sistema Único de Saúde) requires a critical analysis of core concepts of the psychiatric reform, such as 'social reinsertion'. This analysis, oriented by the dialectics of exclusion/inclusion, showed that this concept is impregnated with the adaptation paradigm and asylum view which prevents its effective implantation. The results suggest it is necessary to include social aspects in the discussion of mental health, articulating it with networks of social work and recuperating the revolutionary aspects of the psychiatric reform, thus demarcating the political nature of professional practices.

  9. The Forum for Defence of the Brazilian Unified Health System (Sistema Único de Saúde) and its role in building community participation in the fight against the privatization of health.

    PubMed

    de Lara, Lutiane; Guareschi, Neuza Maria de Fátima

    2016-03-01

    Based on a Foucauldian framework, this article discusses the involvement of the Forum for Defence of the Sistema Único de Saúde in the fight against health care privatization. Community participation is a locus of experience that produces subjects implicated in the production of public health care. The locus of experience in this instance derives from the rejection of private elements that historically have been part of Brazilian public policies. It is an experience that produces workers and service users as agents able to defend the public system and endowed with instituting power. © The Author(s) 2016.

  10. Measured performance of the GTA rf systems

    SciTech Connect

    Denney, P.M.; Jachim, S.P.

    1993-06-01

    This paper describes the performance of the RF systems on the Ground Test Accelerator (GTA). The RF system architecture is briefly described. Among the RF performance results presented are RF field flatness and stability, amplitude and phase control resolution, and control system bandwidth and stability. The rejection by the RF systems of beam-induced disturbances, such as transients and noise, are analyzed. The observed responses are also compared to computer-based simulations of the RF systems for validation.

  11. Measured performance of the GTA rf systems

    SciTech Connect

    Denney, P.M.; Jachim, S.P.

    1993-01-01

    This paper describes the performance of the RF systems on the Ground Test Accelerator (GTA). The RF system architecture is briefly described. Among the RF performance results presented are RF field flatness and stability, amplitude and phase control resolution, and control system bandwidth and stability. The rejection by the RF systems of beam-induced disturbances, such as transients and noise, are analyzed. The observed responses are also compared to computer-based simulations of the RF systems for validation.

  12. Gas exchange measurements in natural systems

    SciTech Connect

    Broecker, W.S.; Peng, T.H.

    1983-01-01

    Direct knowledge of the rates of gas exchange in lakes and the ocean is based almost entirely on measurements of the isotopes /sup 14/C, /sup 222/Rn and /sup 3/He. The distribution of natural radiocarbon has yielded the average rate of CO/sub 2/ exchange for the ocean and for several closed basin lakes. That of bomb produced radiocarbon has been used in the same systems. The /sup 222/Rn to /sup 226/Ra ratio in open ocean surface water has been used to give local short term gas exchange rates. The radon method generally cannot be used in lakes, rivers, estuaries or shelf areas because of the input of radon from sediments. A few attempts have been made to use the excess /sup 3/He produced by decay of bomb produced tritium in lakes to give gas transfer rates. The uncertainty in the molecular diffusivity of helium and in the diffusivity dependence of the rate of gas transfer holds back the application of this method. A few attempts have been made to enrich the surface waters of small lakes with /sup 226/Ra and /sup 3/H in order to allow the use of the /sup 222/Rn and /sup 3/He methods. While these studies give broadly concordant results, many questions remain unanswered. The wind velocity dependence of gas exchange rate has yet to be established in field studies. The dependence of gas exchange rate on molecular diffusivity also remains in limbo. Finally, the degree of enhancement of CO/sub 2/ exchange through chemical reactions has been only partially explored. 49 references, 2 figures, 2 tables.

  13. Description and operation of a microwave reflectance measurement system

    NASA Technical Reports Server (NTRS)

    Lambert, Kevin M.

    1991-01-01

    A recent effort at the NASA Lewis Research Center (LeRC), Microwave System Laboratory was to develop the capability to perform farfield reflectance measurements. This effort has resulted, to date, in a system that can perform X-band, monostatic, measurements of test objects. The system and the measurement procedure are described. Data are presented which assists in the evaluation of the quality of the measurements obtained with the system.

  14. A 3-D measurement system using object-oriented FORTH

    SciTech Connect

    Butterfield, K.B.

    1989-01-01

    Discussed is a system for storing 3-D measurements of points that relates the coordinate system of the measurement device to the global coordinate system. The program described here used object-oriented FORTH to store the measured points as sons of the measuring device location. Conversion of local coordinates to absolute coordinates is performed by passing messages to the point objects. Modifications to the object-oriented FORTH system are also described. 1 ref.

  15. 27 CFR 25.41 - Measuring system required.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., DEPARTMENT OF THE TREASURY LIQUORS BEER Measurement of Beer § 25.41 Measuring system required. The brewer shall accurately and reliably measure the quantity of beer transferred from the brewery cellars...

  16. 27 CFR 25.41 - Measuring system required.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., DEPARTMENT OF THE TREASURY LIQUORS BEER Measurement of Beer § 25.41 Measuring system required. The brewer shall accurately and reliably measure the quantity of beer transferred from the brewery cellars...

  17. 27 CFR 25.41 - Measuring system required.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., DEPARTMENT OF THE TREASURY ALCOHOL BEER Measurement of Beer § 25.41 Measuring system required. The brewer shall accurately and reliably measure the quantity of beer transferred from the brewery cellars...

  18. 27 CFR 25.41 - Measuring system required.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., DEPARTMENT OF THE TREASURY ALCOHOL BEER Measurement of Beer § 25.41 Measuring system required. The brewer shall accurately and reliably measure the quantity of beer transferred from the brewery cellars...

  19. 27 CFR 25.41 - Measuring system required.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., DEPARTMENT OF THE TREASURY LIQUORS BEER Measurement of Beer § 25.41 Measuring system required. The brewer shall accurately and reliably measure the quantity of beer transferred from the brewery cellars...

  20. Calibration system for radon EEC measurements.

    PubMed

    Mostafa, Y A M; Vasyanovich, M; Zhukovsky, M; Zaitceva, N

    2015-06-01

    The measurement of radon equivalent equilibrium concentration (EECRn) is very simple and quick technique for the estimation of radon progeny level in dwellings or working places. The most typical methods of EECRn measurements are alpha radiometry or alpha spectrometry. In such technique, the influence of alpha particle absorption in filters and filter effectiveness should be taken into account. In the authors' work, it is demonstrated that more precise and less complicated calibration of EECRn-measuring equipment can be conducted by the use of the gamma spectrometer as a reference measuring device. It was demonstrated that for this calibration technique systematic error does not exceed 3 %. The random error of (214)Bi activity measurements is in the range 3-6 %. In general, both these errors can be decreased. The measurements of EECRn by gamma spectrometry and improved alpha radiometry are in good agreement, but the systematic shift between average values can be observed.

  1. Measuring Advances in HVAC Distribution System Design

    SciTech Connect

    Franconi, E.

    1998-05-01

    Substantial commercial building energy savings have been achieved by improving the performance of the HV AC distribution system. The energy savings result from distribution system design improvements, advanced control capabilities, and use of variable-speed motors. Yet, much of the commercial building stock remains equipped with inefficient systems. Contributing to this is the absence of a definition for distribution system efficiency as well as the analysis methods for quantifying performance. This research investigates the application of performance indices to assess design advancements in commercial building thermal distribution systems. The index definitions are based on a first and second law of thermodynamics analysis of the system. The second law or availability analysis enables the determination of the true efficiency of the system. Availability analysis is a convenient way to make system efficiency comparisons since performance is evaluated relative to an ideal process. A TRNSYS simulation model is developed to analyze the performance of two distribution system types, a constant air volume system and a variable air volume system, that serve one floor of a large office building. Performance indices are calculated using the simulation results to compare the performance of the two systems types in several locations. Changes in index values are compared to changes in plant energy, costs, and carbon emissions to explore the ability of the indices to estimate these quantities.

  2. Power system applications for phasor measurement units

    SciTech Connect

    Burnett, R.O. Jr. ); Butts, M.M.; Sterlina, P.S.

    1994-01-01

    This article examines the applications for a system that can determine the state of the power system at a given instant over any area. The topics of the article include fault recording applications, disturbance recording applications, transmission and generation modeling verification applications, power system stabilizer test applications, and a discussion of future enhancements and applications.

  3. 49 CFR 325.25 - Calibration of measurement systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Calibration of measurement systems. 325.25 Section... CARRIER NOISE EMISSION STANDARDS Instrumentation § 325.25 Calibration of measurement systems. (a)(1) The sound level measurement system must be calibrated and appropriately adjusted at one or more frequencies...

  4. 43 CFR 12.915 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 43 Public Lands: Interior 1 2013-10-01 2013-10-01 false Metric system of measurement. 12.915... Requirements § 12.915 Metric system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement...

  5. 29 CFR 95.15 - Metric system of measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 1 2014-07-01 2013-07-01 true Metric system of measurement. 95.15 Section 95.15 Labor... Requirements § 95.15 Metric system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205), declares that the metric system is the preferred measurement...

  6. 49 CFR 19.15 - Metric system of measurement.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false Metric system of measurement. 19.15 Section 19.15... Requirements § 19.15 Metric system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205), declares that the metric system is the preferred measurement...

  7. 49 CFR 19.15 - Metric system of measurement.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 1 2014-10-01 2014-10-01 false Metric system of measurement. 19.15 Section 19.15... Requirements § 19.15 Metric system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205), declares that the metric system is the preferred measurement...

  8. 43 CFR 12.915 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 1 2012-10-01 2011-10-01 true Metric system of measurement. 12.915... Requirements § 12.915 Metric system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement...

  9. 49 CFR 19.15 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 1 2012-10-01 2012-10-01 false Metric system of measurement. 19.15 Section 19.15... Requirements § 19.15 Metric system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205), declares that the metric system is the preferred measurement...

  10. 43 CFR 12.915 - Metric system of measurement.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 1 2011-10-01 2011-10-01 false Metric system of measurement. 12.915... Requirements § 12.915 Metric system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205) declares that the metric system is the preferred measurement...

  11. 49 CFR 325.25 - Calibration of measurement systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Calibration of measurement systems. 325.25 Section... CARRIER NOISE EMISSION STANDARDS Instrumentation § 325.25 Calibration of measurement systems. (a)(1) The sound level measurement system must be calibrated and appropriately adjusted at one or more...

  12. 21 CFR 890.1600 - Intermittent pressure measurement system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intermittent pressure measurement system. 890.1600 Section 890.1600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Intermittent pressure measurement system. (a) Identification. An intermittent pressure measurement system is...

  13. 49 CFR 325.25 - Calibration of measurement systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 5 2013-10-01 2013-10-01 false Calibration of measurement systems. 325.25 Section... CARRIER NOISE EMISSION STANDARDS Instrumentation § 325.25 Calibration of measurement systems. (a)(1) The sound level measurement system must be calibrated and appropriately adjusted at one or more frequencies...

  14. 40 CFR 30.15 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Metric system of measurement. 30.15... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 30.15 Metric system of...), declares that the metric system is the preferred measurement system for U.S. trade and commerce. The Act...

  15. 40 CFR 30.15 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 1 2013-07-01 2013-07-01 false Metric system of measurement. 30.15... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 30.15 Metric system of...), declares that the metric system is the preferred measurement system for U.S. trade and commerce. The Act...

  16. 40 CFR 30.15 - Metric system of measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 1 2011-07-01 2011-07-01 false Metric system of measurement. 30.15... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 30.15 Metric system of...), declares that the metric system is the preferred measurement system for U.S. trade and commerce. The Act...

  17. 38 CFR 49.15 - Metric system of measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) declares that the metric system is the preferred measurement system for U.S. trade and commerce. The Act..., when the metric system of measurement will be used in the agency's procurements, grants, and other... 38 Pensions, Bonuses, and Veterans' Relief 2 2011-07-01 2011-07-01 false Metric system of...

  18. The Metric System: America Measures Up. 1979 Edition.

    ERIC Educational Resources Information Center

    Anderson, Glen; Gallagher, Paul

    This training manual is designed to introduce and assist naval personnel in the conversion from the English system of measurement to the metric system of measurement. The book tells what the "move to metrics" is all about, and details why the change to the metric system is necessary. Individual chapters are devoted to how the metric system will…

  19. 38 CFR 49.15 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) declares that the metric system is the preferred measurement system for U.S. trade and commerce. The Act..., when the metric system of measurement will be used in the agency's procurements, grants, and other... 38 Pensions, Bonuses, and Veterans' Relief 2 2013-07-01 2013-07-01 false Metric system of...

  20. 38 CFR 49.15 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) declares that the metric system is the preferred measurement system for U.S. trade and commerce. The Act..., when the metric system of measurement will be used in the agency's procurements, grants, and other... 38 Pensions, Bonuses, and Veterans' Relief 2 2012-07-01 2012-07-01 false Metric system of...

  1. 38 CFR 49.15 - Metric system of measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) declares that the metric system is the preferred measurement system for U.S. trade and commerce. The Act..., when the metric system of measurement will be used in the agency's procurements, grants, and other... 38 Pensions, Bonuses, and Veterans' Relief 2 2014-07-01 2014-07-01 false Metric system of...

  2. Patient-Reported Outcome Measures in Systemic Sclerosis (Scleroderma).

    PubMed

    Pellar, Russell E; Tingey, Theresa M; Pope, Janet Elizabeth

    2016-05-01

    Scleroderma (systemic sclerosis) is a rare autoimmune connective tissue disease that can damage multiple organs and reduce quality of life. Patient-reported outcome measures capture the patient's perspective. Some measures are specific to systemic sclerosis and others are general. Patient-reported outcomes in systemic sclerosis are important to aid in understanding the impact of systemic sclerosis on patients.

  3. Icing research tunnel rotating bar calibration measurement system

    NASA Technical Reports Server (NTRS)

    Gibson, Theresa L.; Dearmon, John M.

    1993-01-01

    In order to measure icing patterns across a test section of the Icing Research Tunnel, an automated rotating bar measurement system was developed at the NASA Lewis Research Center. In comparison with the previously used manual measurement system, this system provides a number of improvements: increased accuracy and repeatability, increased number of data points, reduced tunnel operating time, and improved documentation. The automated system uses a linear variable differential transformer (LVDT) to measure ice accretion. This instrument is driven along the bar by means of an intelligent stepper motor which also controls data recording. This paper describes the rotating bar calibration measurement system.

  4. Ice thickness measurement system for the icing research tunnel calibration

    NASA Technical Reports Server (NTRS)

    Gibson, Theresa L.; Dearmon, John M.

    1993-01-01

    To measure icing patterns across a test section of the Icing Research Tunnel, an automated rotating bar measurement system was developed at NASA LeRC. In comparison with the previously used manual measurement system, this system provides a number of improvements: increased accuracy and repeatability, increased number of data points, reduced tunnel operating time, and improved documentation. The automated system uses a linear variable differential transformer (LVDT) to measure ice accretion. This instrument is driven along the bar by means of an intelligent stepper motor which also controls data recording. This paper describes the rotating bar calibration measurement system.

  5. International Instructional Systems: How England Measures Up

    ERIC Educational Resources Information Center

    Creese, Brian; Isaacs, Tina

    2016-01-01

    Although England was not included in the International Instructional Systems Study because it was not a high-performing jurisdiction by the Study's definition, contributors largely were England-based. Analysing the Study's nine overall aspects of instructional systems, this paper finds that England is out of step with many of the high-performing…

  6. International Instructional Systems: How England Measures Up

    ERIC Educational Resources Information Center

    Creese, Brian; Isaacs, Tina

    2016-01-01

    Although England was not included in the International Instructional Systems Study because it was not a high-performing jurisdiction by the Study's definition, contributors largely were England-based. Analysing the Study's nine overall aspects of instructional systems, this paper finds that England is out of step with many of the high-performing…

  7. Expert system for analyzing eddy current measurements

    DOEpatents

    Levy, Arthur J.; Oppenlander, Jane E.; Brudnoy, David M.; Englund, James M.; Loomis, Kent C.

    1994-01-01

    A method and apparatus (called DODGER) analyzes eddy current data for heat exchanger tubes or any other metallic object. DODGER uses an expert system to analyze eddy current data by reasoning with uncertainty and pattern recognition. The expert system permits DODGER to analyze eddy current data intelligently, and obviate operator uncertainty by analyzing the data in a uniform and consistent manner.

  8. Expert system for analyzing eddy current measurements

    SciTech Connect

    Levy, A.J.; Oppenlander, J.E.; Brudnoy, D.M.; Englund, J.M.; Loomis, K.C.

    1994-08-16

    A method and apparatus (called DODGER) analyzes eddy current data for heat exchanger tubes or any other metallic object. DODGER uses an expert system to analyze eddy current data by reasoning with uncertainty and pattern recognition. The expert system permits DODGER to analyze eddy current data intelligently, and obviate operator uncertainty by analyzing the data in a uniform and consistent manner. 21 figs.

  9. 46 CFR 69.11 - Determining the measurement system or systems for a particular vessel.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Determining the measurement system or systems for a... system or systems for a particular vessel. (a) Convention Measurement System (subpart B). (1) Except as... only on the Great Lakes, unless the owner requests measurement under this system. (iii) A vessel that...

  10. Design of MEMS accelerometer based acceleration measurement system for automobiles

    NASA Astrophysics Data System (ADS)

    Venkatesh, K. Arun; Mathivanan, N.

    2012-10-01

    Design of an acceleration measurement system using a MEMS accelerometer to measure acceleration of automobiles in all the three axes is presented. Electronic stability control and anti-lock breaking systems in automobiles use the acceleration measurements to offer safety in driving. The system uses an ARM microcontroller to quantize the outputs of accelerometer and save the measurement data on a microSD card. A LabVIEW program has been developed to analyze the longitudinal acceleration measurement data and test the measurement system. Random noises generated and added with measurement data during measurement are filtered by a Kalman filter implemented in LabVIEW. Longitudinal velocity of the vehicle is computed from the measurement data and displayed on a graphical chart. Typical measurement of velocity of a vehicle at different accelerations and decelerations is presented.

  11. ANDES Measurements for Advanced Reactor Systems

    NASA Astrophysics Data System (ADS)

    Plompen, A. J. M.; Hambsch, F.-J.; Kopecky, S.; Nyman, M.; Rouki, C.; Salvador Castiñeira, P.; Schillebeeckx, P.; Belloni, F.; Berthoumieux, E.; Gunsing, F.; Lampoudis, C.; Calviani, M.; Guerrero, C.; Cano-Ott, D.; Gonzalez Romero, E.; Aïche, M.; Jurado, B.; Mathieu, L.; Derckx, X.; Farget, F.; Rodrigues Tajes, C.; Bacquias, A.; Dessagne, Ph.; Kerveno, M.; Borcea, C.; Negret, A.; Colonna, N.; Goncalves, I.; Penttilä, H.; Rinta-Antila, S.; Kolhinen, V. S.; Jokinen, A.

    2014-05-01

    A significant number of new measurements was undertaken by the ANDES “Measurements for advanced reactor systems” initiative. These new measurements include neutron inelastic scattering from 23Na, Mo, Zr, and 238U, neutron capture cross sections of 238U, 241Am, neutron induced fission cross sections of 240Pu, 242Pu, 241Am, 243Am and 245Cm, and measurements that explore the limits of the surrogate technique. The latter study the feasibility of inferring neutron capture cross sections for Cm isotopes, the neutron-induced fission cross section of 238Pu and fission yields and fission probabilities through full Z and A identification in inverse kinematics for isotopes of Pu, Am, Cm and Cf. Finally, four isotopes are studied which are important to improve predictions for delayed neutron precursors and decay heat by total absorption gamma-ray spectrometry (88Br, 94Rb, 95Rb, 137I). The measurements which are performed at state-of-the-art European facilities have the ambition to achieve the lowest possible uncertainty, and to come as close as is reasonably achievable to the target uncertainties established by sensitivity studies. An overview is presented of the activities and achievements, leaving detailed expositions to the various parties contributing to the conference.

  12. Measuring rates of outdoor airflow into HVAC systems

    SciTech Connect

    Fisk, William J.; Faulkner, David; Sullivan, Douglas P.; Delp, Woody

    2002-10-01

    During the last few years, new technologies have been introduced for measuring the flow rates of outside air into HVAC systems. This document describes one particular technology for measuring these airflows, a system and a related protocol developed to evaluate this and similar measurement technologies under conditions without wind, and the results of our evaluations. We conclude that the measurement technology evaluated can provide a reasonably accurate measurement of OA flow rate over a broad range of flow, without significantly increasing airflow resistance.

  13. Feasibility of a fetal measurement electrode system

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Findings of the study are summarized and conclude that all monitoring requirements are not currently satisfied. An approach is presented to provide a multiparametric monitoring system through combinations of existing transducers. This monitoring system would be appropriate, not only for intrapartum monitoring, but also for neonatal and adult blood gas evaluations. A literature search was conducted to provide an insight into current state-of-the-art in fetal monitoring.

  14. An automated radar-signature measurement system

    NASA Astrophysics Data System (ADS)

    Kruse, Juergen

    The design and operation of an automated measurement facility permitting determination of radar cross sections and location and characterization of scattering centers on aircraft models up to 4.5 m in length are described and illustrated with diagrams, drawings, graphs, and photographs. The facility comprises a 15 x 5.8 x 3.8-m measurement chamber, a rotating platform with maximum load 270 kg and elevation range from -5 to +35 deg (precision 0.1 deg), a tunable broadband 2-18-GHz transmitter, a phase-sensitive receiver, and control and data-processing computers. The analytical techniques employed to correct for measurement errors and to resolve scattering centers both longitudinally and transversely (two-dimensional representation) are explained and demonstrated. The facility is currently being used to develop and evaluate stealth-type aircraft designs.

  15. Hyperbolic contraction measuring systems for extensional flow

    NASA Astrophysics Data System (ADS)

    Nyström, M.; Tamaddon Jahromi, H. R.; Stading, M.; Webster, M. F.

    2017-08-01

    In this paper an experimental method for extensional measurements on medium viscosity fluids in contraction flow is evaluated through numerical simulations and experimental measurements. This measuring technique measures the pressure drop over a hyperbolic contraction, caused by fluid extension and fluid shear, where the extensional component is assumed to dominate. The present evaluative work advances our previous studies on this experimental method by introducing several contraction ratios and addressing different constitutive models of varying shear and extensional response. The constitutive models included are those of the constant viscosity Oldroyd-B and FENE-CR models, and the shear-thinning LPTT model. Examining the results, the impact of shear and first normal stress difference on the measured pressure drop are studied through numerical pressure drop predictions. In addition, stream function patterns are investigated to detect vortex development and influence of contraction ratio. The numerical predictions are further related to experimental measurements for the flow through a 15:1 contraction ratio with three different test fluids. The measured pressure drops are observed to exhibit the same trends as predicted in the numerical simulations, offering close correlation and tight predictive windows for experimental data capture. This result has demonstrated that the hyperbolic contraction flow is well able to detect such elastic fluid properties and that this is matched by numerical predictions in evaluation of their flow response. The hyperbolical contraction flow technique is commended for its distinct benefits: it is straightforward and simple to perform, the Hencky strain can be set by changing contraction ratio, non-homogeneous fluids can be tested, and one can directly determine the degree of elastic fluid behaviour. Based on matching of viscometric extensional viscosity response for FENE-CR and LPTT models, a decline is predicted in pressure drop for

  16. Hyperbolic contraction measuring systems for extensional flow

    NASA Astrophysics Data System (ADS)

    Nyström, M.; Tamaddon Jahromi, H. R.; Stading, M.; Webster, M. F.

    2017-02-01

    In this paper an experimental method for extensional measurements on medium viscosity fluids in contraction flow is evaluated through numerical simulations and experimental measurements. This measuring technique measures the pressure drop over a hyperbolic contraction, caused by fluid extension and fluid shear, where the extensional component is assumed to dominate. The present evaluative work advances our previous studies on this experimental method by introducing several contraction ratios and addressing different constitutive models of varying shear and extensional response. The constitutive models included are those of the constant viscosity Oldroyd-B and FENE-CR models, and the shear-thinning LPTT model. Examining the results, the impact of shear and first normal stress difference on the measured pressure drop are studied through numerical pressure drop predictions. In addition, stream function patterns are investigated to detect vortex development and influence of contraction ratio. The numerical predictions are further related to experimental measurements for the flow through a 15:1 contraction ratio with three different test fluids. The measured pressure drops are observed to exhibit the same trends as predicted in the numerical simulations, offering close correlation and tight predictive windows for experimental data capture. This result has demonstrated that the hyperbolic contraction flow is well able to detect such elastic fluid properties and that this is matched by numerical predictions in evaluation of their flow response. The hyperbolical contraction flow technique is commended for its distinct benefits: it is straightforward and simple to perform, the Hencky strain can be set by changing contraction ratio, non-homogeneous fluids can be tested, and one can directly determine the degree of elastic fluid behaviour. Based on matching of viscometric extensional viscosity response for FENE-CR and LPTT models, a decline is predicted in pressure drop for

  17. Advanced Measurement Systems Available to PIWG Members

    NASA Technical Reports Server (NTRS)

    Anderson, Robert; Lei, Jih-Fen (Technical Monitor)

    2002-01-01

    It was developed advanced measurement technologies to meet NASA goals: reduce design cycle time, reduce emission, reduce testing time, increase safety. The technology are saving money. This technology are available now for technology transfer: optical diagnostics, the film technology and MEMS devices.

  18. Measuring the ROI on Knowledge Management Systems.

    ERIC Educational Resources Information Center

    Wickhorst, Vickie

    2002-01-01

    Defines knowledge management and corporate portals and provides a model that can be applied to assessing return on investment (ROI) for a knowledge management solution. Highlights include leveraging knowledge in an organization; assessing the value of human capital; and the Intellectual Capital Performance Measurement Model. (LRW)

  19. CONFOCAL MICROSCOPY SYSTEM PERFORMANCE: LASER POWER MEASUREMENTS

    EPA Science Inventory

    Laser power abstract
    The reliability of the confocal laser-scanning microscope (CLSM) to obtain intensity measurements and quantify fluorescence data is dependent on using a correctly aligned machine that contains a stable laser power. The laser power test appears to be one ...

  20. CONFOCAL MICROSCOPY SYSTEM PERFORMANCE: LASER POWER MEASUREMENTS

    EPA Science Inventory

    Laser power abstract
    The reliability of the confocal laser-scanning microscope (CLSM) to obtain intensity measurements and quantify fluorescence data is dependent on using a correctly aligned machine that contains a stable laser power. The laser power test appears to be one ...

  1. Noninvasive polarimetric glucose measurement system for eye phantoms and in-vivo measurement requirements

    NASA Astrophysics Data System (ADS)

    Rawer, Rainer C.; Vollmer, Patrick; Malz, Andre; Stork, Wilhem; Mueller-Glaser, Klaus D.

    2003-10-01

    Non-invasive monitoring of the glucose level is a key technology for improved diagnosis and therapy for Diabetes patients. Optical measurement techniques like polarimetry measuring at the human eye offer promising properties for non-invasive and painless application. This article presents a polarimetric measurement system utilizing the polarizing properties of the Aqueous Humour (AH) for quantative glucose measurements. In particular the special requirements of in-vivo measurements for such a system are discussed.

  2. 21 CFR 870.1130 - Noninvasive blood pressure measurement system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Noninvasive blood pressure measurement system. 870... Noninvasive blood pressure measurement system. (a) Identification. A noninvasive blood pressure measurement... three pressures can be derived through the use of tranducers placed on the surface of the body....

  3. Displacement measurement system for inverters using computer micro-vision

    NASA Astrophysics Data System (ADS)

    Wu, Heng; Zhang, Xianmin; Gan, Jinqiang; Li, Hai; Ge, Peng

    2016-06-01

    We propose a practical system for noncontact displacement measurement of inverters using computer micro-vision at the sub-micron scale. The measuring method of the proposed system is based on a fast template matching algorithm with an optical microscopy. A laser interferometer measurement (LIM) system is built up for comparison. Experimental results demonstrate that the proposed system can achieve the same performance as the LIM system but shows a higher operability and stability. The measuring accuracy is 0.283 μm.

  4. Optoelectronic System Measures Distances to Multiple Targets

    NASA Technical Reports Server (NTRS)

    Liebe, Carl Christian; Abramovici, Alexander; Bartman, Randall; Chapsky, Jacob; Schmalz, John; Coste, Keith; Litty, Edward; Lam, Raymond; Jerebets, Sergei

    2007-01-01

    An optoelectronic metrology apparatus now at the laboratory-prototype stage of development is intended to repeatedly determine distances of as much as several hundred meters, at submillimeter accuracy, to multiple targets in rapid succession. The underlying concept of optoelectronic apparatuses that can measure distances to targets is not new; such apparatuses are commonly used in general surveying and machining. However, until now such apparatuses have been, variously, constrained to (1) a single target or (2) multiple targets with a low update rate and a requirement for some a priori knowledge of target geometry. When fully developed, the present apparatus would enable measurement of distances to more than 50 targets at an update rate greater than 10 Hz, without a requirement for a priori knowledge of target geometry. The apparatus (see figure) includes a laser ranging unit (LRU) that includes an electronic camera (photo receiver), the field of view of which contains all relevant targets. Each target, mounted at a fiducial position on an object of interest, consists of a small lens at the output end of an optical fiber that extends from the object of interest back to the LRU. For each target and its optical fiber, there is a dedicated laser that is used to illuminate the target via the optical fiber. The targets are illuminated, one at a time, with laser light that is modulated at a frequency of 10.01 MHz. The modulated laser light is emitted by the target, from where it returns to the camera (photodetector), where it is detected. Both the outgoing and incoming 10.01-MHz laser signals are mixed with a 10-MHz local-oscillator to obtain beat notes at 10 kHz, and the difference between the phases of the beat notes is measured by a phase meter. This phase difference serves as a measure of the total length of the path traveled by light going out through the optical fiber and returning to the camera (photodetector) through free space. Because the portion of the path

  5. Solar energy control system. [temperature measurement

    NASA Technical Reports Server (NTRS)

    Currie, J. R. (Inventor)

    1981-01-01

    A solar energy control system for a hot air type solar energy heating system wherein thermocouples are arranged to sense the temperature of a solar collector, a space to be heated, and a top and bottom of a heat storage unit is disclosed. Pertinent thermocouples are differentially connected together, and these are employed to effect the operation of dampers, a fan, and an auxiliary heat source. In accomplishing this, the differential outputs from the thermocouples are amplified by a single amplifier by multiplexing techniques. Additionally, the amplifier is corrected as to offset by including as one multiplex channel a common reference signal.

  6. The sequence measurement system of the IR camera

    NASA Astrophysics Data System (ADS)

    Geng, Ai-hui; Han, Hong-xia; Zhang, Hai-bo

    2011-08-01

    Currently, the IR cameras are broadly used in the optic-electronic tracking, optic-electronic measuring, fire control and optic-electronic countermeasure field, but the output sequence of the most presently applied IR cameras in the project is complex and the giving sequence documents from the leave factory are not detailed. Aiming at the requirement that the continuous image transmission and image procession system need the detailed sequence of the IR cameras, the sequence measurement system of the IR camera is designed, and the detailed sequence measurement way of the applied IR camera is carried out. The FPGA programming combined with the SignalTap online observation way has been applied in the sequence measurement system, and the precise sequence of the IR camera's output signal has been achieved, the detailed document of the IR camera has been supplied to the continuous image transmission system, image processing system and etc. The sequence measurement system of the IR camera includes CameraLink input interface part, LVDS input interface part, FPGA part, CameraLink output interface part and etc, thereinto the FPGA part is the key composed part in the sequence measurement system. Both the video signal of the CmaeraLink style and the video signal of LVDS style can be accepted by the sequence measurement system, and because the image processing card and image memory card always use the CameraLink interface as its input interface style, the output signal style of the sequence measurement system has been designed into CameraLink interface. The sequence measurement system does the IR camera's sequence measurement work and meanwhile does the interface transmission work to some cameras. Inside the FPGA of the sequence measurement system, the sequence measurement program, the pixel clock modification, the SignalTap file configuration and the SignalTap online observation has been integrated to realize the precise measurement to the IR camera. Te sequence measurement

  7. 40 CFR 86.405-78 - Measurement system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 19 2013-07-01 2013-07-01 false Measurement system. 86.405-78 Section... 1978 and Later New Motorcycles, General Provisions § 86.405-78 Measurement system. (a) This subpart and subpart F have been written using System International (SI) units. SI units will be used to determine...

  8. 40 CFR 86.405-78 - Measurement system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Measurement system. 86.405-78 Section... 1978 and Later New Motorcycles, General Provisions § 86.405-78 Measurement system. (a) This subpart and subpart F have been written using System International (SI) units. SI units will be used to determine...

  9. 40 CFR 86.405-78 - Measurement system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Measurement system. 86.405-78 Section... 1978 and Later New Motorcycles, General Provisions § 86.405-78 Measurement system. (a) This subpart and subpart F have been written using System International (SI) units. SI units will be used to determine...

  10. 15 CFR 14.15 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Metric system of measurement. 14.15 Section 14.15 Commerce and Foreign Trade Office of the Secretary of Commerce UNIFORM ADMINISTRATIVE... system is the preferred measurement system for U.S. trade and commerce. The Act requires each...

  11. Multi-Antenna Radar Systems for Doppler Rain Measurements

    NASA Technical Reports Server (NTRS)

    Durden, Stephen; Tanelli, Simone; Siqueira, Paul

    2007-01-01

    Use of multiple-antenna radar systems aboard moving high-altitude platforms has been proposed for measuring rainfall. The basic principle of the proposed systems is a variant of that of along-track interferometric synthetic-aperture radar systems used previously to measure ocean waves and currents.

  12. 40 CFR 86.405-78 - Measurement system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Measurement system. 86.405-78 Section... 1978 and Later New Motorcycles, General Provisions § 86.405-78 Measurement system. (a) This subpart and subpart F have been written using System International (SI) units. SI units will be used to determine...

  13. 40 CFR 86.405-78 - Measurement system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Measurement system. 86.405-78 Section... 1978 and Later New Motorcycles, General Provisions § 86.405-78 Measurement system. (a) This subpart and subpart F have been written using System International (SI) units. SI units will be used to determine...

  14. 29 CFR 95.15 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... system for U.S. trade and commerce. The Act requires each Federal agency to establish a date or dates in... 29 Labor 1 2012-07-01 2012-07-01 false Metric system of measurement. 95.15 Section 95.15 Labor... Requirements § 95.15 Metric system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade...

  15. 29 CFR 95.15 - Metric system of measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... system for U.S. trade and commerce. The Act requires each Federal agency to establish a date or dates in... 29 Labor 1 2011-07-01 2011-07-01 false Metric system of measurement. 95.15 Section 95.15 Labor... Requirements § 95.15 Metric system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade...

  16. 22 CFR 518.15 - Metric system of measurement.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... establish a date or dates in consultation with the Secretary of Commerce, when the metric system of... 22 Foreign Relations 2 2014-04-01 2014-04-01 false Metric system of measurement. 518.15 Section... ORGANIZATIONS Pre-Award Requirements § 518.15 Metric system of measurement. The Metric Conversion Act, as...

  17. 49 CFR 19.15 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... system for U.S. trade and commerce. The Act requires each Federal agency to establish a date or dates in... 49 Transportation 1 2013-10-01 2013-10-01 false Metric system of measurement. 19.15 Section 19.15... Requirements § 19.15 Metric system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade...

  18. 29 CFR 95.15 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... system for U.S. trade and commerce. The Act requires each Federal agency to establish a date or dates in... 29 Labor 1 2013-07-01 2013-07-01 false Metric system of measurement. 95.15 Section 95.15 Labor... Requirements § 95.15 Metric system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade...

  19. 22 CFR 518.15 - Metric system of measurement.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... a date or dates in consultation with the Secretary of Commerce, when the metric system of... 22 Foreign Relations 2 2013-04-01 2009-04-01 true Metric system of measurement. 518.15 Section 518... Pre-Award Requirements § 518.15 Metric system of measurement. The Metric Conversion Act, as amended by...

  20. 22 CFR 518.15 - Metric system of measurement.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 22 Foreign Relations 2 2011-04-01 2009-04-01 true Metric system of measurement. 518.15 Section 518... Pre-Award Requirements § 518.15 Metric system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205), declares that the metric system is the...

  1. 22 CFR 518.15 - Metric system of measurement.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 22 Foreign Relations 2 2012-04-01 2009-04-01 true Metric system of measurement. 518.15 Section 518... Pre-Award Requirements § 518.15 Metric system of measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205), declares that the metric system is the...

  2. Ultrasonic system for accurate distance measurement in the air.

    PubMed

    Licznerski, Tomasz J; Jaroński, Jarosław; Kosz, Dariusz

    2011-12-01

    This paper presents a system that accurately measures the distance travelled by ultrasound waves through the air. The simple design of the system and its obtained accuracy provide a tool for non-contact distance measurements required in the laser's optical system that investigates the surface of the eyeball.

  3. Tunnel effect measuring systems and particle detectors

    NASA Technical Reports Server (NTRS)

    Kaiser, William J. (Inventor); Waltman, Steven B. (Inventor); Kenny, Thomas W. (Inventor)

    1993-01-01

    Methods and apparatus for measuring gravitational and inertial forces, magnetic fields, or wave or radiant energy acting on an object or fluid in space provide an electric tunneling current through a gap between an electrode and that object or fluid in space and vary that gap with any selected one of such forces, magnetic fields, or wave or radiant energy acting on that object or fluid. These methods and apparatus sense a corresponding variation in an electric property of that gap and determine the latter force, magnetic fields, or wave or radiant energy in response to that corresponding variation, and thereby sense or measure such parameters as acceleration, position, particle mass, velocity, magnetic field strength, presence or direction, or wave or radiant energy intensity, presence or direction.

  4. Tunnel effect measuring systems and particle detectors

    NASA Technical Reports Server (NTRS)

    Kaiser, William J. (Inventor); Waltman, Steven B. (Inventor); Kenny, Thomas W. (Inventor)

    1994-01-01

    Methods and apparatus for measuring gravitational and inertial forces, magnetic fields, or wave or radiant energy acting on an object or fluid in space provide an electric tunneling current through a gap between an electrode and that object or fluid in space and vary that gap with any selected one of such forces, magnetic fields, or wave or radiant energy acting on that object or fluid. These methods and apparatus sense a corresponding variation in an electric property of that gap and determine the latter force, magnetic fields, or wave or radiant energy in response to that corresponding variation, and thereby sense or measure such parameters as acceleration, position, particle mass, velocity, magnetic field strength, presence or direction, or wave or radiant energy intensity, presence or direction.

  5. Tunnel effect measuring systems and particle detectors

    NASA Technical Reports Server (NTRS)

    Kaiser, William J. (Inventor); Waltman, Steven B. (Inventor); Kenny, Thomas W. (Inventor)

    1994-01-01

    Methods and apparatus for measuring gravitational and inertial forces, magnetic fields, or wave or radiant energy acting on an object or fluid in space provide an electric tunneling current through a gap between an electrode and that object or fluid in space and vary that gap with any selected one of such forces, magnetic fields, or wave or radiant energy acting on that object or fluid. These methods and apparatus sense a corresponding variation in an electric property of that gap and determine the latter force, magnetic fields, or wave or radiant energy in response to that corresponding variation, and thereby sense or measure such parameters as acceleration, position, particle mass, velocity, magnetic field strength, presence or direction, or wave or radiant energy intensity, presence or direction.

  6. Test, Measurement, and Diagnostic Equipment (System Peculiar)

    DTIC Science & Technology

    2007-11-02

    Potential Fault Detection and Isolation Test 4 4.6 Standard Design Characteristics. .. . . . . . 5 4.7 TMDE Interface Tests . . . . . . . . .. . 6 4.8...within purchase description requirements. (3) Any di,crepancies between the TMDE and the "calibrated’ system. 4.5 Potential Fault Detection and Isolation Te

  7. Accuracy of the Iscan Pressure Measurement System

    DTIC Science & Technology

    2001-05-01

    transducer is limited because only the peak pressure and total area are recorded for a given load cycle. The Iscan system ( Tekscan , Boston, MA) makes...aluminum indentors. Both sides of the Tekscan sensor were lubricated with water and surgical jelly to reduce shear. In all tests, a 5 s long ramp function

  8. Blood pressure measurement and display system

    NASA Technical Reports Server (NTRS)

    Farkas, A. J.

    1972-01-01

    System is described that employs solid state circuitry to transmit visual display of patient's blood pressure. Response of sphygmomanometer cuff and microphone provide input signals. Signals and their amplitudes, from turn-on time to turn-off time, are continuously fed to data transmitter which transmits to display device.

  9. Domains of the Florida Performance Measurement System.

    ERIC Educational Resources Information Center

    Florida State Dept. of Education, Tallahassee.

    This monograph sets forth in detail the concepts included in the five domains of teaching as identified by the Florida Coalition for the Development of a Performance Evaluation System. The first domain, planning, includes the concepts: (1) content coverage; (2) utilization of instructional materials; (3) activity structure; (4) goal focusing; and…

  10. Information Systems and Performance Measures in Schools.

    ERIC Educational Resources Information Center

    Coleman, James S.; Karweit, Nancy L.

    Large school systems bring various administrative problems in handling scheduling, records, and avoiding making red tape casualties of students. The authors review a portion of the current use of computers to handle these problems and examine the range of activities for which computer processing could provide aid. Since automation always brings…

  11. Manufacturing Work Measurement System Evaluation. Reference Guide

    DTIC Science & Technology

    1987-04-01

    Arthur Young & Company L 5b. OFFICE SYMBOL (If applicable ) lb. RESTRICTIVE MARKINGS 3. DISTRIBUTION/AVAILABILITY OF REPORT Approved for...ADDRESS (City. State and 7.1P Code) Kansas City, Missouri 64105 8*. NAME OF FUNDING/SPONSORING ORGANIZATION 8b. OFFICE SYMBOL {If applicable ... SUB . GR. 18 SUBJECT TERMS (Continue on reverse if necessary and identify by block number) Work Measurement, Time Standards, Contract Administration

  12. Structural Loads Test Measurement Acquisition System (SLTMAS)

    NASA Technical Reports Server (NTRS)

    Patterson, Alan; Throckmorton, David A. (Technical Monitor)

    2001-01-01

    This presentation package, a PowerPoint presentation, will be presented at NASA's Sixteenth Annual Continual Improvement and Reinvention Conference as part of an Agency level competition highlighting continual improvements within NASA. The presentation provides a brief overview of the process used to improve the Structural and Dynamics Testing Group's data acquisition capabilities. Results measuring the success of the improvement cycle for the PC based SLTMAS will be presented.

  13. Laser System for Precise, Unambiguous Range Measurements

    NASA Technical Reports Server (NTRS)

    Dubovitsky, Serge; Lay, Oliver

    2005-01-01

    The Modulation Sideband Technology for Absolute Range (MSTAR) architecture is the basis of design of a proposed laser-based heterodyne interferometer that could measure a range (distance) as great as 100 km with a precision and resolution of the order of 1 nm. Simple optical interferometers can measure changes in range with nanometer resolution, but cannot measure range itself because interference is subject to the well-known integer-multiple-of-2 -radians phase ambiguity, which amounts to a range ambiguity of the order of 1 m at typical laser wavelengths. Existing rangefinders have a resolution of the order of 10 m and are therefore unable to resolve the ambiguity. The proposed MSTAR architecture bridges the gap, enabling nanometer resolution with an ambiguity range that can be extended to arbitrarily large distances. The MSTAR architecture combines the principle of the heterodyne interferometer with the principle of extending the ambiguity range of an interferometer by using light of two wavelengths. The use of two wavelengths for this purpose is well established in optical metrology, radar, and sonar. However, unlike in traditional two-color laser interferometry, light of two wavelengths would not be generated by two lasers. Instead, multiple wavelengths would be generated as sidebands of phase modulation of the light from a single frequency- stabilized laser. The phase modulation would be effected by applying sinusoidal signals of suitable frequencies (typically tens of gigahertz) to high-speed electro-optical phase modulators. Intensity modulation can also be used

  14. Development of a prototype fluid volume measurement system. [for urine volume measurement on space missions

    NASA Technical Reports Server (NTRS)

    Poppendiek, H. F.; Sabin, C. M.; Meckel, P. T.

    1974-01-01

    The research is reported in applying the axial fluid temperature differential flowmeter to a urine volume measurement system for space missions. The fluid volume measurement system is described along with the prototype equipment package. Flowmeter calibration, electronic signal processing, and typical void volume measurements are also described.

  15. A Data System Architecture for Measurement Based Systems: Precipitation Processing System

    NASA Technical Reports Server (NTRS)

    Stocker, Erich Franz

    2003-01-01

    NASA s Earth Science Enterprise (ESE) is changing focus from single satellite missions to measurement oriented programs. An example of this paradigm shift is the Global Precipitation Measurement (GPM) project. GPM is conceptualized as a rolling-wave of measurement possibilities all focused on the key precipitation parameter. In response to this shift to measurement programs and also integral to the ESE s new strategy for processing and management its data, a measurement based approach is also critical for data processing system that support measurement programs like GPM. This paper provides an overview of the paradigm shift from mission to measurement. It also presents a summary of the ESE s new strategy for its data systems. Building on this background the paper details the architectural, design and implementation aspects of the Precipitation Processing System (PPS). The PPS is an evolution of a single point system developed for the Tropical Rainfall Measurement Mission to a generic precipitation data system. The paper provides the context within which PPS will support the GPM program.

  16. Laser fresnel distance measuring system and method

    NASA Technical Reports Server (NTRS)

    Campbell, Jonathan W. (Inventor); Lehner, David L. (Inventor); Smalley, Larry L. (Inventor); Smith, legal representative, Molly C. (Inventor); Sanders, Alvin J. (Inventor); Earl, Dennis Duncan (Inventor); Allison, Stephen W. (Inventor); Smith, Kelly L. (Inventor)

    2008-01-01

    A method and system for determining range to a target are provided. A beam of electromagnetic energy is transmitted through an aperture in an opaque screen such that a portion of the beam passes through the aperture to generate a region of diffraction that varies as a function of distance from the aperture. An imaging system is focused on a target plane in the region of diffraction with the generated image being compared to known diffraction patterns. Each known diffraction pattern has a unique value associated therewith that is indicative of a distance from the aperture. A match between the generated image and at least one of the known diffraction patterns is indicative of a distance between the aperture and target plane.

  17. Measuring the orthogonality error of coil systems

    USGS Publications Warehouse

    Heilig, B.; Csontos, A.; Pajunpää, K.; White, Tim; St. Louis, B.; Calp, D.

    2012-01-01

    Recently, a simple method was proposed for the determination of pitch angle between two coil axes by means of a total field magnetometer. The method is applicable when the homogeneous volume in the centre of the coil system is large enough to accommodate the total field sensor. Orthogonality of calibration coil systems used for calibrating vector magnetometers can be attained by this procedure. In addition, the method can be easily automated and applied to the calibration of delta inclination–delta declination (dIdD) magnetometers. The method was tested by several independent research groups, having a variety of test equipment, and located at differing geomagnetic observatories, including: Nurmijärvi, Finland; Hermanus, South Africa; Ottawa, Canada; Tihany, Hungary. This paper summarizes the test results, and discusses the advantages and limitations of the method.

  18. Aircraft body-axis rotation measurement system

    NASA Technical Reports Server (NTRS)

    Cowdin, K. T. (Inventor)

    1983-01-01

    A two gyro four gimbal attitude sensing system having gimbal lock avoidance is provided with continuous azimuth information, rather than roll information, relative to the magnetic cardinal headings while in near vertical attitudes to allow recovery from vertical on a desired heading. The system is comprised of a means for stabilizing an outer roll gimbal that is common to a vertical gyro and a directional gyro with respect to the aircraft platform which is being angularly displaced about an axis substantially parallel to the outer roll gyro axis. A means is also provided for producing a signal indicative of the magnitude of such displacement as an indication of aircraft heading. Additional means are provided to cause stabilization of the outer roll gimbal whenever the pitch angle of the aircraft passes through a threshold prior to entering vertical flight and destabilization of the outer roll gimbal upon passing through the threshold when departing vertical flight.

  19. Measurement System for Energetic Materials Decomposition

    DTIC Science & Technology

    2015-01-05

    Pfeiffer Vacuum Benchtop Thermostar Mass Spectrometer 3. Vision Research Phantom V12.1-8G-M high speed camera The views, opinions and/or findings...Decomposition Report Title This DURIP grant was used to purchase: 1. Q600 SDT Simultaneous DSC-TGA 2. Pfeiffer Vacuum Benchtop Thermostar Mass...horizontal purge gas system with digital mass flow controllers and programmable gas switching capability. A separate Inconel 600 tube permits introduction

  20. System for water level measurement based on pressure transducer

    NASA Astrophysics Data System (ADS)

    Paczesny, Daniel; Marzecki, Michał; Woyke, Michał; Tarapata, Grzegorz

    2016-09-01

    The paper reports system for water level measurement, which is designed to be used for measuring liquid levels in the tanks of an autonomous industrial cleaning robot. The selected method of measurement utilized by the designed system is based on pressure measurement. Such system is insensitive on vibrations, foams presence and liquid impurities. The influences of variable pressure on the measurements were eliminated by utilizing the differential method and as well as the system design. The system is capable of measuring water level in tanks up to 400 mm of height with accuracy of about 2,5%. The system was tested in a container during filling and emptying with various liquids. Performed tests exhibited the linearity of the sensor characteristic and the lack of hysteresis. Obtained sensitivity of the sensor prototype was approximately 6,2 mV/mm H2O.

  1. Characterization and measurement of system stability

    NASA Astrophysics Data System (ADS)

    Schieder, R.; Rau, G.; Vowinkel, B.

    To characterize noise and stability of any measuring instrument, a method is offered, based on the principles of the 'Allan variance' used to characterize the stability of frequency standards. The Allan plot has been used to obtain precise information about the noise and drift behavior of all frontends and backends of the Cologne 3-meter millimeter and submillimeter radio telescope. The approach shows how the experimental setup will perform under varying conditions in terms of signal to noise ratio. The method, furthermore, is less complicated to interpret than calculations of the correlation function or the Fourier transform. The Allan plot has been used to test digital voltmeters and digital lock-in amplifiers.

  2. Optical double-slit particle measuring system

    DOEpatents

    Tichenor, D.A.; Wang, J.C.F.; Hencken, K.R.

    1982-03-25

    A method for in situ measurement of particle size is described. The size information is obtained by scanning an image of the particle across a double-slit mask and observing the transmitted light. This method is useful when the particle size of primary interest is 3..mu..m and larger. The technique is well suited to applications in which the particles are non-spherical and have unknown refractive index. It is particularly well suited to high temperature environments in which the particle incandescence provides the light source.

  3. Optical double-slit particle measuring system

    DOEpatents

    Hencken, Kenneth R.; Tichenor, Daniel A.; Wang, James C. F.

    1984-01-01

    A method for in situ measurement of particle size is described. The size information is obtained by scanning an image of the particle across a double-slit mask and observing the transmitted light. This method is useful when the particle size of primary interest is 3 .mu.m and larger. The technique is well suited to applications in which the particles are non-spherical and have unknown refractive index. It is particularly well suited to high temperature environments in which the particle incandescence provides the light source.

  4. S-Nitrosothiol measurements in biological systems.

    PubMed

    Gow, Andrew; Doctor, Allan; Mannick, Joan; Gaston, Benjamin

    2007-05-15

    S-Nitrosothiol (SNO) cysteine modifications are regulated signaling reactions that dramatically affect, and are affected by, protein conformation. The lability of the SNO bond can make SNO-modified proteins cumbersome to measure accurately. Here, we review methodologies for detecting SNO modifications in biology. There are three caveats. (1) Many assays for biological SNOs are used near the limit of detection: standard curves must be in the biologically relevant concentration range. (2) The assays that are most reliable are those that modify SNO protein or peptide chemistry the least. (3) Each result should be quantitatively validated using more than one assay. Improved assays are needed and are in development.

  5. Electrical current measurement system for energy harvesting applications

    NASA Astrophysics Data System (ADS)

    Heller, S.; Mueller, F.; Kroener, M.; Woias, P.

    2016-11-01

    The measurement of the dynamic power consumption is an important task in the field of energy harvesting regarding the characterization and optimization of low power systems. This paper reports on the development and characterization of a computer-controlled measurement system for the measurement of the dynamic current consumption of low power systems in a range from 100 nA to 100 μA, with a time resolution down to 1 μs.

  6. Speckle interferometric system to measure ocular microtremor

    NASA Astrophysics Data System (ADS)

    Ryle, James P.; Al-Kalbani, Mohammed; Collins, Niamh; Gopinathan, Unnikrishnan; Boyle, Gerard; Coakley, Davis; Sheridan, John T.

    2008-04-01

    Ocular microtremor (OMT) is a biological high frequency (up to 150Hz) low amplitude (25-2500nm peak to peak) involuntary motion of the human eye. Clinical OMT investigations to date have used eye-contacting mechanical piezoelectric probes or piezoelectric strain gauges. Before contact can be made, the eye must first be anaesthetized. In some cases, this eyelid spasms occur making it impossible to measure OMT. Using the contact probe method, the eye motion is mechanically loaded. Results from clinical studies with this method to date have given electrical signal amplitudes from the probe proportional to the displacement, but not the exact displacement information. Recent studies suggest a number of clinical applications for OMT, these include monitoring the depth of anesthesia of a patient in surgery, prediction of outcome in coma, diagnosis of brain stem death. In addition to this, in patients with neurological disorders such as Multiple Sclerosis and Parkinson's disease, abnormal OMT frequency content is present. In this paper, we design a compact non-contact phase modulating optical fiber speckle interferometer to measure eye motions. We simulate OMT motion using a calibrated piezoelectric vibration simulator and compare results produced using a contact method with those using our optical non-contact method.

  7. Measurements over distributed high performance computing and storage systems

    NASA Technical Reports Server (NTRS)

    Williams, Elizabeth; Myers, Tom

    1993-01-01

    Requirements are carefully described in descriptions of systems to be acquired but often there is no requirement to provide measurements and performance monitoring to ensure that requirements are met over the long term after acceptance. A set of measurements for various UNIX-based systems will be available at the 1992 Goddard Conference on Mass Storage Systems and Technologies. The authors invite others to contribute to the set of measurements. The framework for presenting the measurements of supercomputers, workstations, file servers, mass storage systems, and the networks that interconnect them are given. Production control and database systems are also included. Though other applications and third party software systems are not addressed, it is important to measure them as well. The capability to integrate measurements from all these components from different vendors, and from the third party software systems was recognized and there are efforts to standardize a framework to do this. The measurement activity falls into the domain of management standards. Standards work is ongoing for Open Systems Interconnection (OSI) systems management; AT&T, Digital, and Hewlett-Packard are developing management systems based on this architecture even though it is not finished. Another effort is in the UNIX International Performance Management Working Group. In addition, there are the Open Systems Foundation's Distributed Management Environment and the Object Management Group. A paper comparing the OSI systems management model and the Object Management Group model has been written. The IBM world has had a capability for measurement for various IBM systems since the 1970's and different vendors were able to develop tools for analyzing and viewing these measurements. Since IBM was the only vendor, the user groups were able to lobby IBM for the kinds of measurements needed. In the UNIX world of multiple vendors, a common set of measurements will not be as easy to get.

  8. Measurements over distributed high performance computing and storage systems

    NASA Technical Reports Server (NTRS)

    Williams, Elizabeth; Myers, Tom

    1993-01-01

    Requirements are carefully described in descriptions of systems to be acquired but often there is no requirement to provide measurements and performance monitoring to ensure that requirements are met over the long term after acceptance. A set of measurements for various UNIX-based systems will be available at the 1992 Goddard Conference on Mass Storage Systems and Technologies. The authors invite others to contribute to the set of measurements. The framework for presenting the measurements of supercomputers, workstations, file servers, mass storage systems, and the networks that interconnect them are given. Production control and database systems are also included. Though other applications and third party software systems are not addressed, it is important to measure them as well. The capability to integrate measurements from all these components from different vendors, and from the third party software systems was recognized and there are efforts to standardize a framework to do this. The measurement activity falls into the domain of management standards. Standards work is ongoing for Open Systems Interconnection (OSI) systems management; AT&T, Digital, and Hewlett-Packard are developing management systems based on this architecture even though it is not finished. Another effort is in the UNIX International Performance Management Working Group. In addition, there are the Open Systems Foundation's Distributed Management Environment and the Object Management Group. A paper comparing the OSI systems management model and the Object Management Group model has been written. The IBM world has had a capability for measurement for various IBM systems since the 1970's and different vendors were able to develop tools for analyzing and viewing these measurements. Since IBM was the only vendor, the user groups were able to lobby IBM for the kinds of measurements needed. In the UNIX world of multiple vendors, a common set of measurements will not be as easy to get.

  9. A Bayesian approach to multivariate measurement system assessment

    SciTech Connect

    Hamada, Michael Scott

    2016-07-01

    This article considers system assessment for multivariate measurements and presents a Bayesian approach to analyzing gauge R&R study data. The evaluation of variances for univariate measurement becomes the evaluation of covariance matrices for multivariate measurements. The Bayesian approach ensures positive definite estimates of the covariance matrices and easily provides their uncertainty. Furthermore, various measurement system assessment criteria are easily evaluated. The approach is illustrated with data from a real gauge R&R study as well as simulated data.

  10. A Bayesian approach to multivariate measurement system assessment

    SciTech Connect

    Hamada, Michael Scott

    2016-07-01

    This article considers system assessment for multivariate measurements and presents a Bayesian approach to analyzing gauge R&R study data. The evaluation of variances for univariate measurement becomes the evaluation of covariance matrices for multivariate measurements. The Bayesian approach ensures positive definite estimates of the covariance matrices and easily provides their uncertainty. Furthermore, various measurement system assessment criteria are easily evaluated. The approach is illustrated with data from a real gauge R&R study as well as simulated data.

  11. Improved Measurement System for Atmospheric Studies

    DTIC Science & Technology

    2015-05-05

    known voltage. o We use a bread board and a 1.5V battery (see Figure 28). o Connect the ground of the 1.5V battery to one of the input for ground (they...Blk-1; 3-4; Wht-6 MN764 Power Wiring 4-11 Tether: The tether used with the winch is a high strength very low stretch braided rope manufactured ...aerodynamic blimp, manufactured by the blimpworks company, and a kite/balloon hybrid system called the helikite from Allsopp inc. The aerodynamic blimp is the

  12. Rotor/bearing system dynamic stiffness measurements

    NASA Technical Reports Server (NTRS)

    Muszynska, A.

    1985-01-01

    Sweep perturbation testing as used in Modal Analysis when applied to a rotating machine has to take into consideration the machine dynamic state of equilibrium at its operational rotative speed. This stands in contrasts to a static equilibrium of nonrotating structures. The rotational energy has a significant influence on rotor dynamic characteristics. The best perturbing input for rotating machines is a forward or reverse rotating, circular force applied directly to the shaft. Determination of Dynamic Stiffness Characteristics of the rotor bearing system by nonsynchronous perturbation of a symmetric rotating shaft supported in one relatively rigid and one oil lubricated bearing.

  13. Performance Evaluation of Velocity Measurement Systems

    DTIC Science & Technology

    1975-04-01

    cosu (t - t-) for 0 < t • t^ < n/u, and 0 for t - t- > TT/W then for a properly selected value of Ui the output e will be 9 •> em ( 1 + costo (t...tower systems and on the CERF sled track for ystems. Dynamic transducer inputs were (over) DD,^N RM 7J 1473 EDITION OF 1 NOV 45 IS OBSOLETE...UNCLASSIFIED SECURITY CLASSIFICATION OF THIS PAGE fl^.n Dmtm Enternd) u^-;c.—, .. . .^ -i^^Mi^ —^ _ 1 a m 1 uwm ii Itttd ASSIFIFn MtCUWITY

  14. Measurement of resilience and its application to enterprise information systems

    NASA Astrophysics Data System (ADS)

    Wang, J. W.; Gao, F.; Ip, W. H.

    2010-05-01

    In this article, we present a measure for resilience in the context of enterprise information systems or service systems in a more general sense. Resilience of the system is a property of the system, which focuses on the recovery ability of the system after a partial damage of the system. Enterprise information systems such as enterprise resource planning, supply chain management, customer relationship management, manufacturing execution system, etc. play a critical role in the daily operation of modern enterprises by timely and sustainable delivery of information. Therefore, resilience is especially important for the enterprise information systems. The proposed measure for resilience is based on the recovery ability of the system, which departs from the existing approaches in literature and presents a unique contribution. An example is given to illustrate how the proposed measure works.

  15. Wireless Fluid-Level Measurement System Equips Boat Owners

    NASA Technical Reports Server (NTRS)

    2008-01-01

    While developing a measurement acquisition system to be used to retrofit aging aircraft with vehicle health monitoring capabilities, Langley Research Center developed an innovative wireless fluid-level measurement system. The NASA technology was of interest to Tidewater Sensors LLC, of Newport News, Virginia, because of its many advantages over conventional fuel management systems, including its ability to provide an accurate measurement of volume while a boat is experiencing any rocking motion due to waves or people moving about on the boat. These advantages led the company to license this novel fluid-level measurement system from NASA for marine applications.

  16. A surface-profile measuring system for synchrotron radiation mirrors

    NASA Astrophysics Data System (ADS)

    Sato, S.; Higashi, Y.; Haya, S.; Otsuka, M.; Yamamoto, H.

    1992-01-01

    The optical head for a new surface-profile measuring system was constructed on the basis of the Twyman-Green interferometer with heterodyne phase detection method. Stability in optical path difference (OPD) was within 2 nm for a fixed point under the well shielded condition. The measured OPD map at the null fringe condition shows the possibility for direct or segment measurement method of aspheric and/or large size mirrors in SR optics. Based on experiments, a new surface-profile measuring system by phase measurement interferometry and segment method is designed. Designed features of the system are briefly reported.

  17. A surface-profile measuring system for synchrotron radiation mirrors

    SciTech Connect

    Sato, S. ); Higashi, Y. ); Haya, S.; Otsuka, M.; Yamamoto, H. )

    1992-01-01

    The optical head for a new surface-profile measuring system was constructed on the basis of the Twyman--Green interferometer with heterodyne phase detection method. Stability in optical path difference (OPD) was within 2 nm for a fixed point under the well shielded condition. The measured OPD map at the null fringe condition shows the possibility for direct or segment measurement method of aspheric and/or large size mirrors in SR optics. Based on experiments, a new surface-profile measuring system by phase measurement interferometry and segment method is designed. Designed features of the system are briefly reported.

  18. Method of measuring heat influx of a cryogenic transfer system

    DOEpatents

    Niemann, Ralph C.; Zelipsky, Steven A.; Rezmer, Ronald R.; Smelser, Peter

    1981-01-01

    A method is provided for measuring the heat influx of a cryogenic transfer system. A gaseous phase of the cryogen used during normal operation of the system is passed through the system. The gaseous cryogen at the inlet to the system is tempered to duplicate the normal operating temperature of the system inlet. The temperature and mass flow rate of the gaseous cryogen is measured at the outlet of the system, and the heat capacity of the cryogen is determined. The heat influx of the system is then determined from known thermodynamic relationships.

  19. Light Sensor System Measuring Declination and Orientation

    NASA Astrophysics Data System (ADS)

    Tambo, Toyokazu; Miyamoto, Yuuji; Sakashita, Shuuhei; Shibata, Miki

    We have proposed and investigated the properties of five-photodiode light sensor (5PD light sensor) which is able to search and track the solar light in the sky. In the present paper, we have focused the estimation about the orientation and declination of the 5PD light sensor regarding the plane of the top photodiode. Those are defined by the rotation of the azimuth and the declination of the elevation at the rotated angle. The rotation and the declination are originated to compare the solar directions between the calculation of solar orbit and the measurement using tracking function of the 5PD light sensor. The derivation is shown, and the estimation is performed on a typical example.

  20. 22 CFR 518.15 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... preferred measurement system for U.S. trade and commerce. The Act requires each Federal agency to establish a date or dates in consultation with the Secretary of Commerce, when the metric system...

  1. 24 CFR 84.15 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) declares that the metric system is the preferred measurement system for U.S. trade and commerce. The Act requires each Federal agency to establish a date or dates in consultation with the Secretary of...

  2. 29 CFR 95.15 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... system for U.S. trade and commerce. The Act requires each Federal agency to establish a date or dates in consultation with the Secretary of Commerce, when the metric system of measurement will be used in the...

  3. 20 CFR 435.15 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... metric system is the preferred measurement system for U.S. trade and commerce. The Act requires each Federal agency to establish a date or dates, in consultation with the Secretary of Commerce, when...

  4. 49 CFR 19.15 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... system for U.S. trade and commerce. The Act requires each Federal agency to establish a date or dates in consultation with the Secretary of Commerce, when the metric system of measurement will be used in the...

  5. 45 CFR 2543.15 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... system is the preferred measurement system for U.S. trade and commerce. The Act requires each Federal agency to establish a date or dates in consultation with the Secretary of Commerce, when the...

  6. 43 CFR 12.915 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... system for U.S. trade and commerce. The Act requires each Federal agency to establish a date or dates in consultation with the Secretary of Commerce when the metric system of measurement will be used in the...

  7. A New Measurement of Time: The Einstein System.

    ERIC Educational Resources Information Center

    Aragon, Mario Rodriguez

    1979-01-01

    Analyzes the concepts of physical time and of the measurement of the magnitude of time, and examines the International System of Units (SI). A proposal for the use of the Einstein system (ES) is also included. (HM)

  8. [An integrated system of blood pressure measurement with bluetooth communication].

    PubMed

    Wang, Wei; Wang, Jing; Sun, Hongyang; Xu, Zuyang; Chai, Xinyu

    2012-07-01

    The development of the integrated blood pressure system with bluetooth communication function is introduced. Experimental results show that the system can complete blood pressure measurement and data transmission wireless effectively, which can be used in m-Health in future.

  9. Tutorial: Clock and Clock Systems Performance Measures

    NASA Technical Reports Server (NTRS)

    Allan, David W.

    1996-01-01

    This tutorial contains basic material - familiar to many. This will be used as a foundation upon which we will build - bringing forth some new material and equations that have been developed especially for this tutorial. These will provide increased understanding toward parameter estimation of clock and clock system's performance. There is a very important International Telecommunications Union (ITU) handbook being prepared at this time which goes much further than this tutorial has time to do. I highly recommend it as an excellent resource document. The final draft is just now being completed, and it should be ready late in 1996. It is an outstanding handbook; Dr. Sydnor proposed to the ITU-R several years ago, and is the editor with my assistance. We have some of the best contributors in the community from around the world who have written the ten chapters in this handbook. The title of the handbook is 'Selection and use of Precise Frequency and Time Systems'. It will be available from the ITU secretariat in Geneva, Switzerland, but NAVTEC Seminars also plans to be a distributor.

  10. Modelling and designing digital control systems with averaged measurements

    NASA Technical Reports Server (NTRS)

    Polites, Michael E.; Beale, Guy O.

    1988-01-01

    An account is given of the control systems engineering methods applicable to the design of digital feedback controllers for aerospace deterministic systems in which the output, rather than being an instantaneous measure of the system at the sampling instants, instead represents an average measure of the system over the time interval between samples. The averaging effect can be included during the modeling of the plant, thereby obviating the iteration of design/simulation phases.

  11. Advanced adhesion and friction measurement system

    NASA Astrophysics Data System (ADS)

    Li, Meng; Huang, Wei; Wang, Xiaolei

    2017-03-01

    An advanced micro-force tester for investigating the micromechanical behavior of various patterned surfaces in dry and wet conditions is presented in this paper. The parallel slice-beam configuration of the tester not only eliminates the large load-dependent slope and tangential displacement at the free end that is found in a single beam system, but also performs a trans-scale deflection with high sensitivity and linearity for force sensing. Meanwhile, the simple structure is characterized by low cost, high efficiency, and ease of fabrication. An integrated nano- and micro-stage comprise the mobile table to produce a large stroke with high resolution, which is specifically required in wet adhesion testing because of the formation of a long liquid bridge. Preliminary experiments of adhesion and friction conducted using PDMS pillars with a plano-convex lens validated the feasibility of this setup.

  12. Feed rate measuring method and system

    DOEpatents

    Novak, J.L.; Wiczer, J.J.

    1995-12-05

    A system and method are provided for establishing the feed rate of a workpiece along a feed path with respect to a machine device. First and second sensors each having first and second sensing electrodes which are electrically isolated from the workpiece are positioned above, and in proximity to the desired surfaces of the workpiece along a feed path. An electric field is developed between the first and second sensing electrodes of each sensor and capacitance signals are developed which are indicative of the contour of the workpiece. First and second image signals representative of the contour of the workpiece along the feed path are developed by an image processor. The time delay between corresponding portions of the first and second image signals are then used to determine the feed rate based upon the separation of the first and second sensors and the amount of time between corresponding portions of the first and second image signals. 18 figs.

  13. Feed rate measuring method and system

    DOEpatents

    Novak, James L.; Wiczer, James J.

    1995-01-01

    A system and method are provided for establishing the feed rate of a workpiece along a feed path with respect to a machine device. First and second sensors each having first and second sensing electrodes which are electrically isolated from the workpiece are positioned above, and in proximity to the desired surfaces of the workpiece along a feed path. An electric field is developed between the first and second sensing electrodes of each sensor and capacitance signals are developed which are indicative of the contour of the workpiece. First and second image signals representative of the contour of the workpiece along the feed path are developed by an image processor. The time delay between corresponding portions of the first and second image signals are then used to determine the feed rate based upon the separation of the first and second sensors and the amount of time between corresponding portions of the first and second image signals.

  14. Method and system for measuring sound velocity

    NASA Technical Reports Server (NTRS)

    Boegeman, Dwight E. (Inventor); Lowenstein, Carl D. (Inventor); Spiess, Fred N. (Inventor)

    1990-01-01

    A method and system for determining the speed of sound in a fluidic medium by determining the travel time of an acoustical signal a predetermined distance in a fluidic medium by generating a cyclical reference signal of a predetermined frequency and transmitting a portion of the reference signal through the medium. The transmitted portion of the reference signal is received after travelling a predetermined distance in the fluidic medium. The cycles of the cyclical reference signal are counted during the period of time between the transmitting and receiving of the portion of the reference signal wherein the travel time of the portion of the reference signal, is the number of cycle counts divided by the frequency. The speed of the acoustical signal through the fluidic medium is a function of the path length divided by the travel time.

  15. Thermal diffusivity measurement system applied to polymers

    NASA Astrophysics Data System (ADS)

    Abad, B.; Díaz-Chao, P.; Almarza, A.; Amantia, D.; Vázquez-Campos, S.; Isoda, Y.; Shinohara, Y.; Briones, F.; Martín-González, M. S.

    2012-06-01

    In the search for cleaner energy sources, the improvement of the efficiency of the actual ones appears as a primary objective. In this way, thermoelectric materials, which are able to convert wasted heat into electricity, are reveal as an interesting way to improve efficiency of car engines, for example. Cost-effective energy harvesting from thermoelectric devices requires materials with high electrical conductivities and Seebeck coefficient, but low thermal conductivity. Conductive polymers can fulfil these conditions if they are doped appropriately. One of the most promising polymers is Polyaniline. In this work, the thermal conductivity of the polyaniline and mixtures of polyaniline with nanoclays has been studied, using a new experimental set-up developed in the lab. The novel system is based on the steady-state method and it is used to obtain the thermal diffusivity of the polymers and the nanocomposites.

  16. 38 CFR 49.15 - Metric system of measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Metric system of... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 49.15 Metric system of...) declares that the metric system is the preferred measurement system for U.S. trade and commerce. The Act...

  17. Performance Measures for Intelligent Systems: From Theory to Experiment

    DTIC Science & Technology

    2003-09-01

    NIST • Manufacturing Engineering Laboratory • Intelligent Systems Division Performance Measures for Intelligent Systems From Theory to...Experiment James Albus Senior NIST Fellow Intelligent Systems Division National Institute of Standards and Technology james.albus@nist.gov Report Documentation...Approved for public release; distribution unlimited 13. SUPPLEMENTARY NOTES PerMIS?03, Performance Metrics for Intelligent Systems , 16-18 Sep 2003

  18. Geodetic measurements with a mobile VLBI system

    NASA Technical Reports Server (NTRS)

    Niell, A. E.; Claflin, E. S.; Lockhart, T. G.; Macdoran, P. F.; Morabito, D. D.; Ong, K. M.; Resch, G. M.

    1980-01-01

    The Project ARIES 9 meter transportable antenna was used as one element of very long baseline interferometer (VLBI) to begin monitoring locations of six sites in California relative to large diameter fixed antennas at the NASA Deep Space Network, Goldstone, California, and at the Caltech Owens Valley Radio Observatory, Big Pine, California. An accuracy of about 6 cm in the horizontal components was demonstrated by comparison with measurements of the National Geodetic Survey. The root of mean square scatter of the lengths of the baselines between any pair of antennas was about 3 cm except for the Goldstone-JPL (Pasadena) baseline. In the period August 1974 to August 1977 the length of this baseline increased by 15 + or - 5 cm as JPL moved westward relative to Goldstone at the rate of 6 + or - 2 cm/year. The baseline lengths were unaffected by the uncertainties of UT1, polar motion, and tropospheric water vapor, which are the limitations to present three dimensional vector accuracies.

  19. Competitiveness measurement system in the advertising sector.

    PubMed

    Poveda-Bautista, Rocío; García-Melón, Mónica; Baptista, Doris C

    2013-01-01

    In this paper a new approach to find indicators that can be used to measure companies' competitiveness and performance in an efficient and reliable way is presented. The aim is to assist managers of companies within a specific industrial sector by providing information about their relative position in the market so as to define better action plans that may improve the company's performance. The approach combines the use of the Analytic Network Process, a multicriteria decision method, with the Balanced Scorecard. It allows the definition of a number of competitiveness indicators based on the performance and setting of the advertising sector. In this way it is possible to obtain a Competitiveness Index that allows a company to know its relative position with respect to other companies in the sector, and establish a ranking of the companies ordered by their competitiveness level. A case study in the advertising industry of Venezuela is provided. Results show that improvement plans for the agencies analyzed should promote creativity, innovation and the use of new technologies, as a particular form of innovation. These factors were considered to be the most relevant indicators in the advertising sector. The participating experts agreed that the methodology is useful and an improvement over current competitiveness assessment methods.

  20. Measuring Isotope Ratios Across the Solar System

    NASA Technical Reports Server (NTRS)

    Webster, Chris R.; Mahaffy, Paul R.

    2012-01-01

    Stable isotope ratios in C, H, N, O and S are powerful indicators of a wide variety of planetary geophysical processes that can identify origin, transport, temperature history, radiation exposure, atmospheric escape, environmental habitability and biology [1]. For the Allan Hills 84001 meteorite, for example, the (sup 1)(sup 3)C/(sup 1)(sup 2)C ratio identifies it as a Mars (SNC) meteorite; the ??K/??Ar ratio tells us the last time the rock cooled to solid, namely 4 Gya; isotope ratios in (sup 3)He, (sup 2)(sup 1)Ne and (sup 3)?Ar show it was in space (cosmic ray exposure) for 10-20 million years; (sup 1)?C dating that it sat in Antarctica for 13,000 years before discovery; and clumped isotope analysis of (sup 1)?O(sup 1)(sup 3)C(sup 1)?O in its carbonate that it was formed at 18+/-4 ?C in a near-surface aqueous environment [2]. Solar System Formation